Sample records for percutaneously deployed left

  1. Percutaneous retrieval of a right atrioventricular embolus.

    PubMed

    Davies, R P; Harding, J; Hassam, R

    1998-01-01

    Percutaneous retrieval of a 12-cm-long serpiginous clot lodged in the right atrium and ventricle is reported. Following bilateral common femoral vein puncture, a Bird's Nest cava filter was first positioned ready to deploy immediately below the renal veins via the right femoral vein. From the left femoral vein, a Cook intravascular retrieval basket was advanced to the right atrium. Under transthoracic echocardiographic visualization, the basket was used to engage, trap, and gently withdraw the clot in a single long strand below the prepositioned inferior vena cava filter. The filter was immediately deployed, leaving the clot trapped inferior to the renal veins, in the cava and left iliac vein. The patient remained well and asymptomatic at discharge.

  2. Percutaneous coil embolization of massive pelvic pseudoaneurysm in an infant.

    PubMed

    Lillis, Anna P; Shaikh, Raja; Alomari, Ahmad I; Chaudry, Gulraiz

    2015-06-01

    Iatrogenic pseudoaneurysm formation is an uncommon but potentially serious complication of cardiac catheterization. This case report describes diagnosis and treatment of a large left external iliac artery pseudoaneurysm in a 3-month-old boy following cardiac catheterization and aortic balloon dilatation for aortic coarctation. A 4-cm pulsatile mass in the left hemipelvis was discovered on MRI performed 6 weeks later for possible tethered spinal cord. Sonography and angiography showed a large pseudoaneurysm of the left external iliac artery just distal to the iliac bifurcation with no flow in the external iliac artery distal to the pseudoaneurysm. Percutaneous US-guided thrombin injection was performed twice, with partial recanalization after each treatment. The residual portion of the pseudoaneurysm was then successfully embolized with percutaneous coils deployed under US and fluoroscopic guidance.

  3. Orbital venous malformation: percutaneous treatment using an electrolytically detachable fibred coil.

    PubMed

    Diolaiuti, Sara; Iizuka, Tateyuki; Schroth, Gerhard; Remonda, Luca; Laedrach, Kurt; El-Koussy, Marwan; Frueh, Beatrice E; Goldblum, David

    2009-03-01

    To report the efficacy of percutaneous treatment of an orbital venous malformation with an electrolytically detachable fibred coil. We report an instance of radiography-guided percutaneous treatment with an electrolytically detachable fibred coil in a 16-year-old boy with acute, spontaneous, painless proptosis on the left side, which progressed with time. Magnetic resonance imaging, angiography and orbitophlebography revealed a low-flow, intraorbital venous malformation. Percutaneous puncture and drainage were followed by a short remission. Following an acute recurrence, a single detachable fibred coil was deployed via a percutaneous approach under angiographic guidance. No radiological or clinical recurrences were observed over 4 years. Embolization of a deep orbital venous malformation with detachable fibred coils via a percutaneous approach can be highly effective, and may be considered before proceeding with open surgery.

  4. Stent-Graft Placement for Femoral Artery Pseudoaneurysm in a Patient with Idiopathic Multiple Arterial Aneurysmal Disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koo, Bon Kwon; Choi, Donghoon; Kwon, Kihwan

    2002-12-15

    A 34-year-old man presenting with a left inguinal mass was diagnosed as having idiopathic multiple aneurysmal disease and pseudoaneurysm of a left superficial femoral artery. A stent-graft was successfully deployed percutaneously at the left superficial femoral artery pseudoaneurysm. Less invasive treatment should be used to avoid vascular complications in patients with idiopathic multiple aneurysmal disease, especially in those who have a progressive course or a history of prior complications after surgical repair.

  5. Use of the aortoatrial continuity as means of providing left ventricular assist support without entering the ventricle: a feasibility study.

    PubMed

    Friedman, Paul A; Kushwaha, Sudhir S; Bruce, Charles J; Park, Soon J; Ladewig, Dorothy J; Mikell, Susan B; Johnson, Susan B; Suddendorf, Scott H; Danielsen, Andrew J; Asirvatham, Samuel J

    2011-06-01

    Left ventricular assist devices (LVADs) are increasingly used to treat patients with refractory heart failure. Current-generation LVADs have major limitations, including the need for open chest surgery, limiting their widespread use. We hypothesized that the aortoatrial continuity could be used as a unique anatomic vantage point for entirely percutaneous LVAD placement. Forty human autopsied hearts were examined to ascertain the presence and define the dimensions of the continuity between the posterior aortic wall and the left atrium. In all cases, a "septum" between the aorta and left atrium was identified. In 3 animal experiments, a custom mechanical shunt was deployed in the wall between the left atrium and noncoronary cusp. With continuous intracardiac ultrasound imaging, and at necropsy, there was no evidence of device dislodgement, pericardial effusion, or aortic or coronary artery trauma noted. It is feasible to use the wall between the aorta and left atrium as an access route for a potentially entirely percutaneous LVAD. Such a system obviates the need for accessing the left ventricle, minimizing complications. In the future, such devices may allow widespread treatment of heart failure, malignant cardiac arrhythmia, and severe aortic and mitral valvular disease. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. Successful percutaneous coronary intervention with GuideLiner® catheter for subtotal occlusive lesion in the right coronary artery with anomalous origin from the left sinus of Valsalva: a case report.

    PubMed

    Shirota, Ayumi; Nomura, Tetsuya; Kubota, Hiroshi; Taminishi, Shunta; Urata, Ryota; Sugimoto, Takeshi; Higuchi, Yusuke; Kato, Taku; Keira, Natsuya; Tatsumi, Tetsuya

    2015-07-28

    Because of the unusual anatomy of an anomalous origin of the right coronary artery from the left sinus of Valsalva, selective cannulation of the guiding catheter in percutaneous coronary intervention for these cases is always challenging. A 58-year-old Japanese man was admitted to our hospital complaining of worsening exertional chest pain. He was suspected of having unstable angina pectoris and underwent cardiac catheterization. We found a subtotal occlusive lesion in the mid-portion of his right coronary artery that originated from the left sinus of Valsalva. On the previous percutaneous coronary intervention, we failed to cannulate the guiding catheter to the anomalous orifice of the right coronary artery. Therefore, we decided to use the GuideLiner catheter for stable back-up support from the beginning. A 6Fr GuideLiner catheter was introduced into the right coronary artery by anchoring it coaxially with a semi-compliant balloon catheter. And we successfully deployed two drug-eluting stents by crossing over the posterior-descending artery. Final angiography demonstrated favorable dilatation of the target lesion, and native blood flow in the right coronary artery was completely recovered. GuideLiner is a monorail-type "child" support catheter that facilitates coaxial guiding catheter engagement and an appropriate back-up force, achieving successful device delivery to target lesions in this kind of complex percutaneous coronary intervention.

  7. Anomalous Coronary Artery From the Opposite Sinus (ACAOS): Technical Challenges During Percutaneous Coronary Intervention.

    PubMed

    Sinha, Santosh Kumar; Razi, Mahmodula; Mahrotra, Anupam; Aggarwal, Puneet; Singh, Anupam; Rekwal, Lokendra; Tripathi, Sunil; Abhishekh, Nishant Kumar; Krishna, Vinay

    2018-04-01

    Anomalies of the coronary arteries are reported in 1-2% of patients among diagnostic angiogram. Ectopic origin of right coronary artery (RCA) from opposite sinus is one of the most common and they are mainly benign, but at times may be malignant. We report a case of a 69-year-old male who underwent early invasive percutaneous coronary intervention for non-ST-segment elevation myocardial infarction (NSTEMI) where RCA arising from left sinus at the root of left main artery was culprit and various technical challenges were encountered while intervening in form of cannulation to tracking of hardwares. RCA was cannulated with floating wire technique using hockey stick guide catheter and revascularized by deployment of 3.5 × 38 mm Promus Premier Everolimus eluting stent (Boston Scientific, USA). To the best of our knowledge, this is the first ever report of ectopic RCA being revascularized by using hockey stick catheter.

  8. Incremental benefit of three-dimensional transesophageal echocardiography in the assessment of left main coronary artery stent protrusion.

    PubMed

    Arisha, Mohammed J; Hsiung, Ming C; Ahmad, Amier; Nanda, Navin C; Elkaryoni, Ahmed; Mohamed, Ahmed H; Yin, Wei-Hsian

    2017-06-01

    Ostial lesions represent a challenging clinical scenario and percutaneous intervention (PCI) of left main coronary artery ostial lesions has been associated with postintervention complications, including protrusion of deployed stents into a sinus of Valsalva or aortic root. We report a case of stent protrusion into the aortic root following aorto-ostial left main coronary artery PCI, in which three-dimensional transesophageal echocardiography (3DTEE) provided incremental benefit over standard two-dimensional images. Specifically, 3DTEE confirmed the presence of stent protrusion by allowing clear visualization of the stent scaffold, in addition to characterizing the relationship between the stent and surrounding structures. © 2017, Wiley Periodicals, Inc.

  9. Management of a large atrial septal occluder embolized to the left ventricular outflow tract without the use of cardiac surgery.

    PubMed

    Loh, Joshua P; Satler, Lowell F; Slack, Michael C

    2014-09-01

    Transcatheter closure of secundum-type atrial septal defects (ASDs) using the AMPLATZER™ Septal Occluder (ASO) has been in use for more than a decade since its US Food and Drug Administration approval in 2001. Device embolization remains an uncommon complication, which can sometimes occur after the initial deployment. Previous reports of ASO devices embolized to the left ventricle have primarily been managed by open-heart surgical retrieval. We present a case of an ASO device embolized to the left ventricular outflow tract (LVOT) 18 hr after initial implantation, which was successfully retrieved percutaneously, followed by successful closure of the ASD using a larger device. © 2014 Wiley Periodicals, Inc.

  10. Management of significant left main coronary disease before and after trans-apical transcatheter aortic valve replacement in a patient with severe and complex arterial disease.

    PubMed

    Paradis, Jean-Michel; George, Isaac; Kodali, Susheel

    2013-09-01

    We report the case of an 81-year-old woman with symptomatic severe aortic stenosis, extremely significant peripheral arterial disease, and obstructive coronary artery disease who underwent percutaneous coronary intervention via a transaxillary conduit immediately before a trans-apical transcatheter aortic valve replacement performed with a transfemoral device. After deployment of the transcatheter heart valve, there was a left main coronary obstruction and the patient required an emergent PCI. This multifaceted case clearly underlines the importance of a well functioning heart team including the interventional cardiologist, the cardiovascular surgeon, and the echocardiographer. Copyright © 2013 Wiley Periodicals, Inc.

  11. Platelet counts on admission affect coronary flow, myocardial perfusion and left ventricular systolic function after primary percutaneous coronary intervention.

    PubMed

    Sharif, Dawod; Abu-Salem, Mira; Sharif-Rasslan, Amal; Rosenschein, Uri

    2017-10-01

    Patients with acute ST-elevation myocardial infarction (STEMI) and increased platelet count treated by fibrinolysis have worse outcomes. The aim of this study was to test the hypothesis that platelet blood count at admission in patients with acute STEMI treated by primary percutaneous coronary intervention affects coronary flow, myocardial perfusion and recovery of left ventricular systolic function. A total of 174 patients presenting with acute anterior STEMI and treated with primary percutaneous coronary intervention were included and divided into subgroups of admission platelet blood count of <200 K, 200-300 K, 300-400 K and >400 K. Evaluation of coronary artery flow and myocardial blush grade was performed according to the TIMI criteria. Electrocardiographic ST elevation resolution post-primary percutaneous coronary intervention was evaluated. Doppler echocardiographic evaluation of left anterior descending coronary artery velocities early and late after primary percutaneous coronary intervention and assessment of left ventricular ejection fraction and wall motion score index (WMSI) of left ventricular and left anterior descending coronary artery territory were performed. Post-primary percutaneous coronary intervention TIMI, myocardial blush grade and ST elevation resolution were similar in all groups. Patients with platelet counts <200 K had higher peak diastolic left anterior descending coronary artery velocity both early and late after primary percutaneous coronary intervention, and higher prevalence of left anterior descending coronary artery velocity deceleration time exceeding 600 ms, (45.5% vs. 40%, P<0.05). Patients with platelet counts >400 K presented with worse left ventricular ejection fraction, left ventricular WMSI and left anterior descending coronary artery WMSI, and before discharge this subgroup had worse left ventricular WMSI and left anterior descending coronary artery WMSI, P<0.01. Patients with anterior STEMI treated by primary percutaneous coronary intervention with lower admission platelet count had higher left anterior descending coronary artery diastolic velocities, better myocardial perfusion with more patients having left anterior descending coronary artery-descending coronary artery velocity deceleration time >600 ms. Patients with higher platelet counts had lower left ventricular systolic function both at admission and before discharge.

  12. Usefulness and Safety of a Guide Catheter Extension System for the Percutaneous Treatment of Complex Coronary Lesions by a Transradial Approach

    PubMed Central

    García-Blas, Sergio; Núñez, Julio; Mainar, Luis; Miñana, Gema; Bonanad, Clara; Racugno, Paolo; Rodríguez, Juan Carlos; Moyano, Patricia; Sanchis, Juan

    2015-01-01

    Objective The aim of this study was to describe our initial experience with the GuideLiner® catheter (Vascular Solutions Inc.) in the transradial treatment of complex lesions. Materials and Methods The clinical, angiographic and procedural data of percutaneous coronary interventions where GuideLiner was used during 2013 were collected. The transradial approach was used in all cases. The indication for its use, efficacy and periprocedural complications were determined. Sixteen consecutive procedures (in 15 patients; 12 males and 3 females) were evaluated. The indication for the use of GuideLiner was a difficulty to advance and properly position a stent through a tortuous and/or calcified artery despite using high-support guide catheters or other useful techniques. Results Of the 16 angiographic procedures, 14 (87.5s%) were successful (stent deployment in 13 cases and a drug-eluting balloon in 1 case). Unsuccessful cases were a chronic total occlusion and a diffusely diseased left anterior descendant artery. A type B dissection of a proximal left circumflex artery was the only periprocedural complication. Conclusion Use of the GuideLiner was an effective and safe technique for the percutaneous treatment of complex coronary lesions in which the adequate progress of angioplasty devices had failed. GuideLiner was particularly helpful when using the transradial approach. Only one minor complication was recorded. PMID:25531292

  13. Usefulness and safety of a guide catheter extension system for the percutaneous treatment of complex coronary lesions by a transradial approach.

    PubMed

    García-Blas, Sergio; Núñez, Julio; Mainar, Luis; Miñana, Gema; Bonanad, Clara; Racugno, Paolo; Rodríguez, Juan Carlos; Moyano, Patricia; Sanchis, Juan

    2015-01-01

    The aim of this study was to describe our initial experience with the GuideLiner® catheter (Vascular Solutions Inc.) in the transradial treatment of complex lesions. The clinical, angiographic and procedural data of percutaneous coronary interventions where GuideLiner was used during 2013 were collected. The transradial approach was used in all cases. The indication for its use, efficacy and periprocedural complications were determined. Sixteen consecutive procedures (in 15 patients; 12 males and 3 females) were evaluated. The indication for the use of GuideLiner was a difficulty to advance and properly position a stent through a tortuous and/or calcified artery despite using high-support guide catheters or other useful techniques. Of the 16 angiographic procedures, 14 (87.5%) were successful (stent deployment in 13 cases and a drug-eluting balloon in 1 case). Unsuccessful cases were a chronic total occlusion and a diffusely diseased left anterior descendant artery. A type B dissection of a proximal left circumflex artery was the only periprocedural complication. Use of the GuideLiner was an effective and safe technique for the percutaneous treatment of complex coronary lesions in which the adequate progress of angioplasty devices had failed. GuideLiner was particularly helpful when using the transradial approach. Only one minor complication was recorded. © 2014 S. Karger AG, Basel.

  14. Percutaneous fiber optic angioscopy of the left ventricle in patients with rheumatic valvular disease

    NASA Astrophysics Data System (ADS)

    Hirose, Junichi; Oshima, Tomomitsu; Fujimori, Yoshiharu; Uchida, Yasumi

    1993-05-01

    Recent advances in fiberoptic technology enabled us to observe percutaneously the cardiac chambers and valves. We examined left ventricular luminal and valvular changes by percutaneous fiberoptic angioscopy in patients with rheumatic valvular disease. Six patients with echocardiographic rheumatic changes in the mitral valves, underwent angioscopy during routine cardiac catheterization. The fiberscope 4.2 F in diameter, and the guiding catheter 9 F in external diameter with an inflatable balloon around the distal most tip were used for angioscopy. The left ventricular endocardial surface was diffusely white in color or white and brown in mosaic fashion. Echocardiography and angiography had low sensitivity for detecting the changes of the left ventricular luminal surface. Whitish changes which were observed by angioscopy were not related to the indices derived from echocardiography and angiography. The results indicate the possibility of percutaneous angioscopy in detecting left ventricular luminal changes in patients with rheumatic valvular disease.

  15. Apical closure device for full-percutaneous transapical valve implantation: stress-test in an animal model†.

    PubMed

    Ferrari, Enrico; Demertzis, Stefanos; Angelella, Jennifer; Berdajs, Denis; Tozzi, Piergiorgio; Moccetti, Tiziano; Maisano, Francesco; von Segesser, Ludwig K

    2017-05-01

    Transapical valve implantation is traditionally performed through a left antero-lateral mini-thoracotomy. A self-expandable apical closure device has recently been developed for full-percutaneous transapical valve implantation. We performed haemodynamics stress-tests on an animal model to evaluate the sealing properties. Under general anaesthesia 5 pigs (mean weight: 67 ± 6 Kg) received full heparinization (100 IU/Kg; activated clotting time >250 s and, through inferior mini-sternotomies, 21-Fr introducer sheaths for transapical aortic valve implantation (outer diameter: 25-Fr) were placed over-the-wire in the apexes. Delivery-catheters carrying folded occluders (SAFEX TM final design) were inserted in the introducer sheaths and plugs were then deployed under fluoroscopic guidance. Phase 1: after protamine injection, apical bleeding was monitored for 1 h with standard haemodynamics condition. Phase 2: we induced systemic hypertension with adrenaline infusion to test the sealing properties under stress. Animals were sacrificed after Phase 2 and hearts were removed and inspected. Five plugs were successfully introduced and deployed in 5 pig hearts. Plugs provided good apical sealing in each animal and a mean of 7 ± 4 ml of blood lost per animal was collected during Phase 1: haemodynamics remained stable and no plug dislodgement was detected (mean blood pressure: 52 ± 9 mmHg). During Phase 2, mean systolic and diastolic peak levels reached 268 ± 24 mmHg and 175 ± 17 mmHg, respectively, without plug dislodgment or bleeding. Post-mortem inspection showed good plug deployment and fixation without myocardial damage. The new apical occluder seals large-sized apical access sites in animal models also during induced systemic hypertension. This pilot study is a further step towards full-percutaneous transapical valve procedures in the clinical setting. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  16. Transapical access closure: the TA PLUG device†

    PubMed Central

    Brinks, Henriette; Nietlispach, Fabian; Göber, Volkhard; Englberger, Lars; Wenaweser, Peter; Meier, Bernhard; Carrel, Thierry; Huber, Christoph

    2013-01-01

    OBJECTIVES Percutaneous closure of the transapical (TA) access site for large-calibre devices is an unsolved issue. We report the first experimental data on the TA PLUG device for true-percutaneous closure following large apical access for transcatheter aortic valve implantation. METHODS The TA PLUG, a self-sealing full-core closure device, was implanted in an acute animal study in six pigs (60.2 ± 0.7 kg). All the pigs received 100 IU/kg of heparin. The targeted activated clotting time was left to normalize spontaneously. After accessing the left ventricular apex with a 39 French introducer, the closure plug device was delivered with a 33 French over-the-wire system under fluoroscopic guidance into the apex. Time to full haemostasis as well as rate of bleeding was recorded. Self-anchoring properties were assessed by haemodynamic push stress under adrenalin challenge. An additional feasibility study was conducted in four pigs (58.4 ± 1.1 kg) with full surgical exposure of the apex, and assessed device anchoring by pull-force measurements with 0.5 Newton (N) increments. All the animals were electively sacrified. Post-mortem analysis of the heart was performed and the renal embolic index assessed. RESULTS Of six apical closure devices, five were correctly inserted and fully deployed at the first attempt. One became blocked in the delivery system and was placed successfully at the second attempt. In all the animals, complete haemostasis was immediate and no leak was recorded during the 5-h observation period. Neither leak nor any device dislodgement was observed under haemodynamic push stress with repeated left ventricular peak pressure of up to 220 mmHg. In the feasibility study assessing pull-stressing, device migration occurred at a force of 3.3 ± 0.5 N corresponding to 247.5 mmHg. Post-mortem analyses confirmed full expansion of all devices at the intended target. No macroscopic damage was identified at the surrounding myocardium. The renal embolic index was zero. CONCLUSIONS True-percutaneous left ventricular apex closure following large access is feasible with the self-sealing TA PLUG. The device allows for immediate haemostasis and a reliable anchoring in the acute animal setting. This is the first report of a true-percutaneous closure for large-calibre transcatheter aortic valve implantation access. PMID:23842759

  17. Percutaneous transfemoral-transseptal implantation of a second-generation CardiAQ mitral valve bioprosthesis: first procedure description and 30-day follow-up.

    PubMed

    Ussia, Gian Paolo; Quadri, Arshad; Cammalleri, Valeria; De Vico, Pasquale; Muscoli, Saverio; Marchei, Massimo; Ruvolo, Giovanni; Sondergaard, Lars; Romeo, Francesco

    2016-02-01

    Transcatheter mitral valve implantation for mitral valve regurgitation is in the very early phase of development because of challenging anatomy and device dimensions. We describe the procedure of a transfemoral-transseptal implantation of the second-generation CardiAQ mitral valve bioprosthesis and 30-day follow-up. The procedure was performed percutaneously, without any left extracorporeal circulatory support. The patient had severe mitral regurgitation with severely depressed ventricular function and other comorbidities. The patient was deemed extreme high risk for conventional cardiac surgery by a multidisciplinary team. The main procedural steps were the creation of an arteriovenous loop with an exchange nitinol wire, and the use of a customised "steerable snare system" to facilitate the catheter delivery system into the mitral annulus. Transoesophageal echocardiography and fluoroscopy were utilised for device positioning and deployment. The mitral valve prosthesis was implanted with mild mitral regurgitation. The postoperative course was uneventful and at 30-day follow-up the patient is in NYHA Class I, with good function of the mitral valve bioprosthesis. This procedure shows that percutaneous transfemoral transcatheter mitral valve implantation is feasible, safe and successful. Further experience is needed to render this procedure clinically available.

  18. AMPLATZER versus Figulla occluder for transcatheter patent foramen ovale closure.

    PubMed

    Trabattoni, Daniela; Gaspardone, Achille; Sgueglia, Gregory A; Fabbiocchi, Franco; Gioffrè, Gaetano; Montorsi, Piero; Calligaris, Giuseppe; Iamele, Maria; De Santis, Antonella; Bartorelli, Antonio L

    2017-04-20

    The aim of this observational study was to compare acute and 12-month results of percutaneous closure of patent foramen ovale (PFO) with two occluder devices. Between June 2007 and October 2014, 406 consecutive patients (48.1±13.3 years, 243 women) underwent percutaneous PFO closure with either the AMPLATZER (n=179) or the Figulla (n=227) device after a stroke or a transient ischaemic attack ascribed to the PFO. A right-to-left shunt grade >1 was previously detected in all patients and atrial septal aneurysm was present in 111 (27.5%) patients. Patients were followed up with a contrast transthoracic echocardiogram and clinically at 24 hours, six months, and 12 months after the procedure. A high procedural success was observed in both groups. Despite a trend towards a higher incidence of acute residual shunt immediately after device deployment among Figulla occluder patients, a residual grade ≥2 right-to-left shunt was observed in 4.5% of patients, independently of the device used for PFO closure. The only difference reported after Figulla device implantation was a lower rate of supraventricular arrhythmias (9% vs. 17%, p=0.02). According to this two-centre study, PFO closure appears safe and effective with the Figulla occluder as well as with the AMPLATZER device.

  19. Regression of left ventricular dilation after percutaneous closure of a large intralobar pulmonary sequestration.

    PubMed

    Alvarez, Alejandro; Borgia, Francesco; Guccione, Paolo

    2010-02-01

    We describe an infant of 8 months who presented with left ventricular dilation due to an extensive intralobar sequestration of the right lung. The pulmonary sequestration was associated with a patent arterial duct and a right aortic arch. Percutaneous closure of the anomalous aberrant artery feeding the sequestrated lung resulted in prompt regression of the left ventricular enlargement.

  20. Unprotected Left Main Disease: Indications and Optimal Strategies for Percutaneous Intervention.

    PubMed

    Li, Jun; Patel, Sandeep M; Parikh, Manish A; Parikh, Sahil A

    2016-03-01

    Although the incidence of left main (LM) coronary artery disease is relatively low in patients undergoing routine angiography, it is a common presentation in patients with acute coronary syndromes. With the current interventional tools and techniques, percutaneous intervention for LM disease has become a viable alternative to the traditional coronary artery bypass grafting. Factors that contribute to the success and appropriateness of percutaneous intervention for LM disease include coronary anatomy and patient-specific factors such as left ventricular function. Multiple considerations should be taken into account prior to intervention, including hemodynamic support if necessary, intravascular imaging to guide therapy, and stent technique. This review provides an overview of the current body of literature to support the use of percutaneous intervention in LM disease and serves as guideline for the interventionalist approaching LM revascularization.

  1. Percutaneous Repair of Postoperative Mitral Regurgitation After Left Ventricular Assist Device Implant.

    PubMed

    Cork, David P; Adamson, Robert; Gollapudi, Raghava; Dembitsky, Walter; Jaski, Brian

    2018-02-01

    Mitral regurgitation commonly improves after implantation of a left ventricular assist device without concomitant valvular repair owing to the mechanical unloading of the left ventricle. However, the development (or persistence) of significant mitral regurgitation after implantation of a left ventricular assist device is associated with adverse clinical events. We present a case of a left ventricular assist device patient who successfully underwent a percutaneous MitraClip procedure for repair of persistent late postoperative mitral insufficiency with demonstrable clinical and hemodynamic improvement. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Percutaneous biliary covered stent insertion in patients with malignant duodenobiliary obstruction.

    PubMed

    Lee, Eunsol; Gwon, Dong Il; Ko, Gi-Young; Sung, Kyu-Bo; Yoon, Hyun-Ki; Shin, Ji Hoon; Kim, Jin Hyoung; Ko, Heung Kyu; Song, Ho-Young

    2015-02-01

    Although the use of polytetrafluoroethylene (PTFE)-covered biliary stents has proven to be feasible for the treatment of benign and malignant biliary disease, less is known regarding the outcomes of percutaneous placement of a covered stent in patients with malignant duodenobiliary obstruction. To investigate the technical and clinical efficacy of the percutaneous placement of a PTFE-covered biliary stent in patients with malignant duodenobiliary obstruction. From April 2007 to September 2012, the medical records of 45 consecutive patients with malignant duodenobiliary obstruction were retrospectively reviewed. All percutaneous biliary stent deployment was performed using PTFE-covered stents, whereas duodenal stent insertion was performed either fluoroscopically or endoscopically using covered or uncovered stents. Biliary stent deployment was technically successful in all patients. None of the stents migrated after deployment. Procedure-related minor complications, including self-limiting hemobilia, occurred in three (7%) patients. Successful internal drainage was achieved in 39 (87%) of the 45 patients. The median survival time after biliary stent placement was 62 days (95% confidence interval, 8-116 days), and the cumulative stent patency rates at 1, 3, 6, and 12 months were 96%, 92%, 75%, and 38%, respectively. The causes of biliary stent dysfunction included stent occlusion caused by a subsequently inserted duodenal stent (n = 7), food impaction (n = 3), and sludge incrustation (n = 1). One patient developed acute cholecystitis 131 days after biliary stent placement and underwent percutaneous transhepatic gallbladder drainage. Percutaneous insertion of a PTFE-covered stent is a safe and effective method for palliative treatment of patients with malignant duodenobiliary obstruction. If possible, subsequent biliary stent insertion is preferable in order to prevent possible biliary stent dysfunction caused by subsequent insertion of a duodenal stent. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  3. Left Atrial Appendage Closure for Stroke Prevention: Devices, Techniques, and Efficacy.

    PubMed

    Iskandar, Sandia; Vacek, James; Lavu, Madhav; Lakkireddy, Dhanunjaya

    2016-05-01

    Left atrial appendage closure can be performed either surgically or percutaneously. Surgical approaches include direct suture, excision and suture, stapling, and clipping. Percutaneous approaches include endocardial, epicardial, and hybrid endocardial-epicardial techniques. Left atrial appendage anatomy is highly variable and complex; therefore, preprocedural imaging is crucial to determine device selection and sizing, which contribute to procedural success and reduction of complications. Currently, the WATCHMAN is the only device that is approved for left atrial appendage closure in the United States. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Long-term outcome after percutaneous closure of persistent left superior caval vein draining into the left atrium: a contrast-enhanced CT study.

    PubMed

    Marini, Davide; Castagno, Matteo; Millesimo, Michele; Ferroni, Francesca; Ferraro, Gaetana; Pace Napoleone, Carlo; Agnoletti, Gabriella

    2017-10-01

    Data regarding long-term outcome after percutaneous closure of left superior caval vein draining into the left atrium are lacking. The aim of the present study was to report the long-term follow-up by using contrast-enhanced CT. In all, three patients underwent percutaneous closure of left superior caval vein draining into the left atrium between 2005 and 2015. All of them were evaluated clinically and underwent contrast-enhanced CT. In one patient, the Amplatzer® Septal Occluder was used. In two patients, the Amplatzer® Vascular Plug type-1 was preferred: the device size/LSVC diameter ratio was 1.7 in the child and 1.2 in the adult. There were no early-onset or long-term onset complications. CT was performed 1, 2, and 10 years after the procedure, respectively. Complete occlusion of the vessel was documented in all. After 10 years since the procedure, CT revealed a persistent trivial residual shunt through the accessory hemiazygos vein in one patient, in whom the device was implanted above its drainage into the left superior caval vein. When an Amplatzer® Vascular Plug type-1 is oversized compared with the venous vessel diameter, it immediately assumes a dog-bone shape that disappears early to regain its shape memory and nominal size. Percutaneous occlusion of left superior caval vein draining into the left atrium has excellent early and long-term outcomes. The optimal implantation of the device is below the drainage of the accessory hemiazygos vein, when present. The device might be oversized compared with the left superior caval vein diameter according to the age of the patient.

  5. Canine model of acute aortic rupture: treatment with percutaneous delivery of a covered Z stent--work in progress.

    PubMed

    Williams, D M; Andrews, J C; Chee, S S; Marx, M V; Abrams, G D

    1994-01-01

    To develop a percutaneous treatment for aortic rupture with use of a covered intraluminal stent. A transmural tear was created percutaneously in the thoracic aorta in six dogs with use of a 4-mm angioplasty balloon. Gianturco Z stents were covered with polytetrafluoroethylene, loaded into a 14-F sheath, and advanced through the femoral artery to the site of injury. Within 2 minutes after initiation of the injury, the stent was deployed. Homologous canine blood was given during the procedure. Dogs that survived 24 hours were then killed. The first stent did not expand completely, and the dog died in 1 hour. At necropsy, the first two dogs (1-hour and 8-hour survival) had a large left hemothorax and extensive periaortic hematoma, indicating intrathoracic exsanguination. The next four dogs were treated with a modified stent and survived 2 hours (n = 1), 8 hours (n = 1), and 24 hours (n = 2). At necropsy hemothorax did not exceed 15 mL, and periaortic hematomas were small. The cause of death in the two early casualties with the modified stent is uncertain. There were no signs of spinal cord injury despite occlusion of three pairs of intercostal arteries. The covered Z stent (in its modified form) tamponaded the aortic tear, preventing exsanguination. Long-term studies of biocompatibility of this device appear justified.

  6. Percutaneous closure of a giant left ventricular wall pseudoaneurysm: Anterograde approach with a double snare technique.

    PubMed

    Afonso Nogueira, Marta; Fiarresga, António; de Sousa, Lídia; Agapito, Ana; Galrinho, Ana; Cruz Ferreira, Rui

    2016-01-01

    Left ventricular pseudoaneurysm is a rare complication of acute myocardial infarction, cardiac surgery, trauma or infection. Since surgical repair is associated with high morbidity and mortality, percutaneous closure has been described as an alternative. In this regard, we present a case in which a symptomatic large left ventricular pseudoaneurysm was treated by percutaneous closure due to the patient's high surgical risk, using a double snare technique. Despite the technical difficulties, this procedure had a good final result followed by clinical success, confirming that this procedure is an effective alternative to surgery in high-risk patients. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Percutaneous left ventricular assist device with TandemHeart for high-risk percutaneous coronary intervention: the Mayo Clinic experience.

    PubMed

    Alli, Oluseun O; Singh, Inder M; Holmes, David R; Pulido, Juan N; Park, Soon J; Rihal, Charanjit S

    2012-11-01

    In patients with poor left ventricular function and severe left main or multivessel coronary disease, coronary artery bypass grafting (CABG) surgery has been the preferred therapy. However, a number of these patients are either inoperable or poor surgical candidates due to comorbid conditions and previous cardiac surgical procedures. These patients are generally poor candidates for standard percutaneous coronary intervention (PCI) techniques. A hybrid PCI approach with hemodynamic support may be a viable strategy for these patients. We report our experience using the TandemHeart percutaneous left ventricular assist device during high-risk PCI. Retrospective cross-sectional analysis of prospectively collected data in 54 patients undergoing high-risk PCI using the TandemHeart device for support. Hemodynamic and clinical data were collected and analyzed. Baseline clinical characteristics were as follows: mean age 72 ± 1.7 years, males 78%, median ejection fraction 20%, mean serum creatinine 1.6 ± 0.3 2 mg/dL, recent myocardial infarction 52%, COPD 33%, previous CABG 50%, diabetes mellitus 41%, and hypertension 83%. The median SYNTAX score was 33, and the median Jeopardy score was 10. The predicted surgical revascularization mortality was 13% by the Society for Thoracic Surgery risk score and 33% by Euroscore. There was a significant decrease in right and left heart pressures (P < 0.05) with a concomitant increase in the cardiac output from 4.7 to 5.7 L/min (P = 0.03) during TandemHeart support. Left main and multivessel PCI was performed in 62% of patients, and rotablation was used in 48%. Procedural success rate was 97%, whereas 30-day and 6 month survival were 90% and 87%, respectively. Major vascular complications occurred in 13% of cases. None of our patients developed contrast induced nephropathy or needed dialysis. High-risk PCI with percutaneous left ventricular support using TandemHeart is a viable therapeutic strategy for a select subset of patients at very high risk with standard percutaneous revascularization techniques. Copyright © 2012 Wiley Periodicals, Inc.

  8. Percutaneous Coronary Intervention of Left Main Disease: Pre- and Post-EXCEL (Evaluation of XIENCE Everolimus Eluting Stent Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization) and NOBLE (Nordic-Baltic-British Left Main Revascularization Study) Era.

    PubMed

    Park, Duk-Woo; Park, Seung-Jung

    2017-06-01

    For nearly half a century, coronary artery bypass grafting has been the standard treatment for patients with obstructive left main coronary artery (LMCA) disease. However, there has been considerable evolution in the field of percutaneous coronary intervention, and especially, percutaneous coronary intervention for LMCA disease has been rapidly expanded with adoption of drug-eluting stents. Some, but not all randomized trials, have shown that percutaneous coronary intervention with drug-eluting stents might be a suitable alternative for selected patients with LMCA disease instead of bypass surgery. However, none of previous trials involving early-generation drug-eluting stents was sufficiently powered and comparative trials using contemporary drug-eluting stents were limited. Recently, primary results of 2 new trials of EXCEL (Evaluation of XIENCE Everolimus Eluting Stent Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization) and NOBLE (Nordic-Baltic-British Left Main Revascularization Study) were reported. However, these trials showed conflicting results, which might pose uncertainty on the optimal revascularization strategy for LMCA disease. In this article, with the incorporation of a key review on evolution of LMCA treatment, we summarize the similarity or disparity of the EXCEL and NOBLE trials, focus on how they relate to previous trials in the field, and finally speculate on how the treatment strategy may be changed or recommended for LMCA treatment. © 2017 American Heart Association, Inc.

  9. Endovascular approach to treat ascending aortic pseudoaneurysm in a patient with previous CABG and very high surgical risk.

    PubMed

    Zago, Alexandre C; Saadi, Eduardo K; Zago, Alcides J

    2011-10-01

    Pseudoaneurysm of the ascending aorta is an uncommon pathology and a challenge in high-risk patients who undergo conventional surgery because of high operative morbidity and mortality. Endovascular exclusion of an aortic pseudoaneurysm using an endoprosthesis is a less invasive approach, but few such cases have been reported. Moreover, the use of this approach poses unique therapeutic challenges because there is no specific endoprosthesis for ascending aortic repair, particularly to treat patients with previous coronary artery bypass graft (CABG). We describe the case of a 74-year-old patient who had undergone CABG and later presented with an iatrogenic ascending aortic pseudoaneurysm that occurred during an angiography. This patient was at very high risk for surgical treatment and, therefore, an endovascular approach was adopted: percutaneous coronary intervention for the left main coronary artery, left anterior descending and left circumflex native coronary arteries followed by endovascular endoprosthesis deployment in the ascending aorta to exclude the pseudoaneurysm. Both procedures were successfully performed, and the patient was discharged without complications 4 days later. At 5 months' clinical follow-up, his clinical condition was good and he had no complications. Copyright © 2011 Wiley-Liss, Inc.

  10. Percutaneous closure of the left atrial appendage in patients with diabetes mellitus.

    PubMed

    Azizy, Obayda; Rammos, Christos; Lehmann, Nils; Rassaf, Tienush; Kälsch, Hagen

    2017-09-01

    Left atrial appendage closure is a preventive treatment of atrial fibrillation-related thrombo-embolism. Patients with diabetes mellitus have increased risk for a negative outcome in percutaneous cardiac interventions. We assessed whether percutaneous left atrial appendage closure is safe and effective in patients with diabetes mellitus. We included 78 patients (mean age of 74.4 ± 8.3 years) with indication for left atrial appendage closure in an open-label observational single-centre study. Patients with diabetes mellitus ( n = 31) were at higher thrombo-embolic and bleeding risk (CHA 2 DS 2 -VASc: 4.5 ± 0.9, HAS-BLED: 4.7 ± 0.7) compared to patients without diabetes mellitus ( n = 47, CHA 2 DS 2 -VASc: 3.5 ± 1.0, HAS-BLED: 4.1 ± 0.8; p < 0.001 for both). Pre- and periprocedural risk was elevated in patients with diabetes mellitus (Euro II-Score: 6.6 ± 3.7 vs 3.9 ± 1.9, p < 0.01; Society of Thoracic Surgeons (STS)-Score: 4.0 ± 2.5 vs 2.6 ± 1.2, p < 0.01). Procedural success was similar. Periprocedural major adverse cardiac and cerebrovascular events occurred in one patient from the control group (2.1%), whereas patients with diabetes mellitus had no events ( p = 0.672). Follow-up of 6 months revealed no bleeding complication in both groups. No stroke occurred in follow-up, and left atrial appendage flow velocity reduction (55.6 ± 38.6 vs 51.4 ± 19.1 cm/s, p = 0.474) and rate of postinterventional leakage in the left atrial appendage were comparable (0% vs 2.1%, p = 0.672). Despite patients with diabetes mellitus are high-risk patients, the outcome of percutaneous left atrial appendage closure is similar to patients without diabetes mellitus.

  11. Percutaneous discal cyst rupture in a professional football player using sublaminar epidural injection for thecal sac displacement.

    PubMed

    Friedman, Michael V; Park, Andrew; Bumpass, David; Jennings, Jack W; Matava, Matthew J

    2015-01-01

    A case of percutaneous discal cyst rupture in a 25-year-old professional American football player is reported. The patient presented with a 3-day history of severe left-sided back pain. Magnetic resonance imaging examination demonstrated a discal cyst effacing the left L4-L5 lateral recess, with interposed thecal sac. A sublaminar epidural injection was performed displacing the thecal sac, exposing the discal cyst, and allowing for percutaneous perforation. The patient had complete resolution of symptoms after discal cyst rupture and was able to compete in a professional football game 3 days later. Computed tomography-guided percutaneous rupture is a therapeutic modality that may be considered for treatment of a symptomatic discal cyst. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.

  12. [Lung perfusion studies after percutaneous closure of patent ductus arteriosus using the Amplatzer Duct Occluder in children].

    PubMed

    Parra-Bravo, José Rafael; Apolonio-Martínez, Adriana; Estrada-Loza, María de Jesús; Beirana-Palencia, Luisa Gracia; Ramírez-Portillo, César Iván

    2015-01-01

    The closure of patent ductus arteriosus with multiple devices has been associated with a reduction in lung perfusion. We evaluated the pulmonary perfusion after percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder device using perfusion lung scan. Thirty patients underwent successful percutaneous patent ductus arteriosus occlusions using the Amplatzer Duct Occluder device were included in this study. Lung perfusion scans were preformed 6 months after the procedure. Peak flow velocities and protrusion of the device were analyzed by Doppler echocardiography. A left lung perfusion<40% was considered abnormal. The device implantation was successful in all patients. Average perfusion of left lung was 44.7±4.9% (37.8-61.4). Five patients (16.6%) showed decreased perfusion of the left lung. Age, low weight, the length of the ductus arteriosus and the minimum and maximum diameter/length of the ductus arteriosus ratio were statistically significant in patients with abnormalities of lung perfusion. It was observed protrusion the device in 6 patients with a higher maximum flow rate in the left pulmonary artery. The left lung perfusion may be compromised after percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder. The increased flow velocity in the origin of the left pulmonary artery can be a poor indicator of reduction in pulmonary perfusion and can occur in the absence of protrusion of the device. Copyright © 2014 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  13. A highly articulated robotic surgical system for minimally invasive surgery.

    PubMed

    Ota, Takeyoshi; Degani, Amir; Schwartzman, David; Zubiate, Brett; McGarvey, Jeremy; Choset, Howie; Zenati, Marco A

    2009-04-01

    We developed a novel, highly articulated robotic surgical system (CardioARM) to enable minimally invasive intrapericardial therapeutic delivery through a subxiphoid approach. We performed preliminary proof of concept studies in a porcine preparation by performing epicardial ablation. CardioARM is a robotic surgical system having an articulated design to provide unlimited but controllable flexibility. The CardioARM consists of serially connected, rigid cyclindrical links housing flexible working ports through which catheter-based tools for therapy and imaging can be advanced. The CardioARM is controlled by a computer-driven, user interface, which is operated outside the operative field. In six experimental subjects, the CardioARM was introduced percutaneously through a subxiphoid access. A commercial 5-French radiofrequency ablation catheter was introduced through the working port, which was then used to guide deployment. In all subjects, regional ("linear") left atrial ablation was successfully achieved without complications. Based on these preliminary studies, we believe that the CardioARM promises to enable deployment of a number of epicardium-based therapies. Improvements in imaging techniques will likely facilitate increasingly complex procedures.

  14. Percutaneous transluminal alcohol septal myocardial ablation after aortic valve replacement

    NASA Technical Reports Server (NTRS)

    Sitges, M.; Kapadia, S.; Rubin, D. N.; Thomas, J. D.; Tuzcu, M. E.; Lever, H. M.

    2001-01-01

    When left ventricular outflow tract obstruction develops after aortic valve replacement, few treatment choices have been available until now. We present a patient with prior aortic valve replacement who developed left ventricle outflow tract obstruction that was successfully treated with a percutaneous transcoronary myocardial septal alcohol ablation. This technique is a useful tool for the treatment of obstructive hypertrophic cardiomyopathy, especially in those patients with prior heart surgery. Copyright 2001 Wiley-Liss, Inc.

  15. Design and Development of a Miniaturized Percutaneously Deployable Wireless Left Ventricular Assist Device: Early Prototypes and Feasibility Testing.

    PubMed

    Letzen, Brian; Park, Jiheum; Tuzun, Zeynep; Bonde, Pramod

    The current left ventricular assist devices (LVADs) are limited by a highly invasive implantation procedure in a severely unstable group of advanced heart failure patients. Additionally, the current transcutaneous power drive line acts as a nidus for infection resulting in significant morbidity and mortality. In an effort to decrease this invasiveness and eliminate drive line complications, we have conceived a wireless miniaturized percutaneous LVAD, capable of being delivered endovascularly with a tether-free operation. The system obviates the need for a transcutaneous fluid purge line required in existing temporary devices by utilizing an incorporated magnetically coupled impeller for a complete seal. The objective of this article was to demonstrate early development and proof-of-concept feasibility testing to serve as the groundwork for future formalized device development. Five early prototypes were designed and constructed to iteratively minimize the pump size and improve fluid dynamic performance. Various magnetic coupling configurations were tested. Using SolidWorks and ANSYS software for modeling and simulation, several geometric parameters were varied. HQ curves were constructed from preliminary in vitro testing to characterize the pump performance. Bench top tests showed no-slip magnetic coupling of the impeller to the driveshaft up to the current limit of the motor. The pump power requirements were tested in vitro and were within the appropriate range for powering via a wireless energy transfer system. Our results demonstrate the proof-of-concept feasibility of a novel endovascular cardiac assist device with the potential to eventually offer patients an untethered, minimally invasive support.

  16. Ultrasound-guided, percutaneous peripheral nerve stimulation: technical note.

    PubMed

    Chan, Isaac; Brown, Anthony R; Park, Kenneth; Winfree, Christopher J

    2010-09-01

    Peripheral nerve stimulation is a form of neuromodulation that applies electric current to peripheral nerves to induce stimulation paresthesias within the painful areas. To report a method of ultrasound-guided, percutaneous peripheral nerve stimulation. This technique utilizes real-time imaging to avoid injury to adjacent vascular structures during minimally invasive placement of peripheral nerve stimulator electrodes. We describe a patient that presented with chronic, bilateral foot pain following multiple foot surgeries, for whom a comprehensive, pain management treatment strategy had failed. We utilized ultrasound-guided, percutaneous tibial nerve stimulation at a thigh level to provide durable pain relief on the right side, and open peripheral nerve stimulation on the left. The patient experienced appropriate stimulation paresthesias and excellent pain relief on the plantar aspect of the right foot with the percutaneous electrode. On the left side, we were unable to direct the stimulation paresthesias to the sole of the foot, despite multiple electrode repositionings. A subsequent, open placement of a left tibial nerve stimulator was performed. This revealed that the correct electrode position against the tibial nerve was immediately adjacent to the popliteal artery, and was thus not appropriate for percutaneous placement. We describe a method of ultrasound-guided peripheral nerve stimulation that avoids the invasiveness of electrode placement via an open procedure while providing excellent pain relief. We further describe limitations of the percutaneous approach when navigating close to large blood vessels, a situation more appropriately managed with open peripheral nerve stimulator placement. Ultrasound-guided placement may be considered for patients receiving peripheral nerve stimulators placed within the deep tissues, and not easily placed in a blind fashion.

  17. Percutaneous intervention of chronic total occlusion of anomalous right coronary artery originating from left sinus – Use of mother and child technique using guideliner

    PubMed Central

    Senguttuvan, Nagendra Boopathy; Sharma, Samin K.; Kini, Annapoorna

    2015-01-01

    Anomalous origin of right coronary artery (RCA) from left sinus is a rare clinical entity. Percutaneous coronary intervention of such an anomalous RCA, which is chronically occluded, is difficult and is rarely described. We describe such an intervention in a patient, who had a chronic total occlusion of anomalous RCA and discuss the technical issues associated with such interventions. PMID:26995429

  18. Hypoplastic left heart syndrome - a review of supportive percutaneous treatment.

    PubMed

    Moszura, Tomasz; Góreczny, Sebastian; Dryżek, Paweł

    2014-01-01

    Due to the complex anatomical and haemodynamic consequences of hypoplastic left heart syndrome (HLHS), patients with the condition require multistage surgical and supportive interventional treatment. Percutaneous interventions may be required between each stage of surgical palliation, sometimes simultaneously with surgery as hybrid interventions, or after completion of multistage treatment. Recent advances in the field of interventional cardiology, including new devices and techniques, have significantly contributed to improving results of multistage HLHS palliation. Knowledge of the potential interventional options as well as the limitation of percutaneous interventions will enable the creation of safe and effective treatment protocols in this highly challenging group of patients. In this comprehensive review we discuss the types, goals, and potential complications of transcatheter interventions in patients with HLHS.

  19. Coherex WAVECREST I Left Atrial Appendage Occlusion Study

    ClinicalTrials.gov

    2015-01-13

    Non-valvular Paroxysmal, Persistent, or Permanent Atrial Fibrillation; LAA Anatomy Amenable to Treatment by Percutaneous Technique; Anticoagulation Indication for Potential Thrombus Formation in the Left Atrium

  20. Aortocoronary dissection with acute left main artery occlusion: successful treatment with emergent stenting.

    PubMed

    Wykrzykowska, Joanna J; Carrozza, Joseph; Laham, Roger J

    2006-08-01

    Iatrogenic aortocoronary dissection is a rare but devastating complication of percutaneous coronary interventions and cardiac surgery, with a mortality rate up to 35%. Of the type-A dissections in the International Registry of Aortic Dissections (IRAD), 27% were caused by coronary interventions. The mechanism involves an initial dissection in the coronary artery, which then propagates in a retrograde fashion past the sinuses of Valsalva, often several centimeters beyond the aortic valve. With the advent of complex interventions such as left main stent implantation, revascularization of chronic total occlusions and mechanical thrombectomy, this complication may become more prevalent. Here we present a unique case of percutaneous coronary intervention (PCI) of the left circumflex (LCx) artery complicated by a left main coronary dissection that propagated approximately 8 cm into the ascending aorta and caused abrupt left main coronary artery occlusion and hemodynamic collapse. Rescue of the left main artery and sealing of the aortic dissection with stabilization of the patient was possible with rapid ostial left main artery stenting.

  1. Life-Threatening Complication During Percutaneous Ablation of Adrenal Gland Metastasis: Takotsubo Syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsoumakidou, Georgia, E-mail: gtsoumakidou@yahoo.com; Buy, Xavier, E-mail: Xavier.buy@chru-strasbourg.f; Zickler, Pierre, E-mail: pierre.zickler@chru-strasbourg.f

    2010-06-15

    A rare life-threatening complication during percutaneous cryoablation of an adrenal gland metastasis from a lung carcinoma is reported. The patient presented hypertensive crisis at the beginning of the thawing cycle, followed by electrocardiographic change which necessitated interruption of the procedure and his transfer to the intensive care unit with suspicion of heart infarct. There was a slight increase in cardiac enzyme levels, and ventricular angiography demonstrated transient hypokinesis-dyskinesis of the mid left ventricular segments without apical involvement, while the coronary arteries showed no significant stenosis on coronarography. These findings led to the diagnosis of Takotsubo cardiomyopathy left ventricular dysfunction syndrome.more » This is the first case of Takotsubo cardiomyopathy occurring as a complication during percutaneous ablation of an adrenal gland tumor.« less

  2. Palliative percutaneous transhepatic drainage for inoperable obstructive jaundice.

    PubMed Central

    Baxter-Smith, D. C.; Temple, J. G.; Howarth, F.

    1982-01-01

    A technique of percutaneous transhepatic drainage under local anaesthesia is described for the relief of intractable pruritus in patients with obstructive jaundice due to inoperable carcinoma. After standard percutaneous transhepatic cholangiography a polyethylene catheter is introduced into one of the large dilated bile ducts and left in situ, thereby establishing external retrograde biliary drainage. The technique has been used successfully in 6 cases with reduction in serum bilirubin levels and relief of pruritus. PMID:6182832

  3. Pulmonary artery perforation by plug anchoring system after percutaneous closure of left appendage.

    PubMed

    Bianchi, Giacomo; Solinas, Marco; Gasbarri, Tommaso; Bevilacqua, Stefano; Tiwari, Kaushal Kishore; Berti, Sergio; Glauber, Mattia

    2013-07-01

    Patients receiving oral anticoagulant therapy for atrial fibrillation who are at high risk of bleeding are increasingly referred for percutaneous left atrial appendage exclusion. Although effective, this procedure is not free from risk. We report a case of pericardial tamponade due to pulmonary artery tear caused by a trespassing anchoring hook of an AGA plug. Intraoperatively, no actual bleeding was found from the left appendage, a proof of its complete occlusion by the device. The patient underwent successful surgical repair and radio-frequency ablation of atrial fibrillation was performed by pulmonary veins encircling. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Transoral approach for percutaneous vertebroplasty in the treatment of osteolytic tumor lesions of the lateral mass of the atlas: feasibility and initial experience in 2 patients.

    PubMed

    Clarençon, Frédéric; Cormier, Evelyne; Pascal-Moussellard, Hugues; Maldent, Jean-Baptiste; Pichon, Soizic; Le Jean, Lise; Ikka, Léon; Chiras, Jacques

    2013-02-01

    Case series. To report our early experience of percutaneous vertebro-plasty via a transoral approach of the lesions of the lateral mass of C1. Percutaneous vertebroplasty has gained acceptance for the treatment of osteolytic lesions of the spine. However, scant data are available on the percutaneous vertebroplasty of the C1 lesions. Two patients (a 74-yr-old female and a 53-yr-old male) presenting respectively a metastasis of the left lateral mass of C1 from a pancreatic adenocarcinoma and a hemangioma of the left lateral mass of C1 underwent a percutaneous vertebroplasty via a transoral approach in a hybrid angio suite associating a monoplane flat panel and a computed tomography scan, using polymethylmetacrilate bone cement.For the second patient, a nondetachable balloon was used to protect the vertebral artery from cement leakage. Satisfactory filing of the lesions was obtained in both patients. No complication was recorded. Both patients experienced pain improvement. Transoral approach for the treatment of osteolytic tumor lesions of the lateral mass of the atlas is feasible and seems to be a safe and effective technique.

  5. Left Atrial Appendage Exclusion for Atrial Fibrillation

    PubMed Central

    Syed, Faisal F.; DeSimone, Christopher V.; Friedman, Paul A.; Asirvatham, Samuel J.

    2015-01-01

    SYNOPSIS Percutaneous left atrial appendage (LAA) closure is increasingly being used as a treatment strategy to prevent stroke in patients with atrial fibrillation (AF) who have contraindications to anticoagulants. A number of approaches and devices have been developed in the last few years, each with their own unique set of advantages and disadvantages. We review the published studies on surgical and percutaneous approaches to LAA closure; focusing on stroke mechanisms in AF, LAA structure and function relevant to stroke prevention, practical differences in procedural approach, and clinical considerations surrounding management. PMID:25443240

  6. Percutaneous Direct Puncture Embolization with N-butyl-cyanoacrylate for High-flow Priapism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tokue, Hiroyuki, E-mail: tokue@s2.dion.ne.jp; Shibuya, Kei; Ueno, Hiroyuki

    There are many treatment options in high-flow priapism. Those mentioned most often are watchful waiting, Doppler-guided compression, endovascular highly selective embolization, and surgery. We present a case of high-flow priapism in a 57-year-old man treated by percutaneous direct puncture embolization of a post-traumatic left cavernosal arteriovenous fistula using N-butyl-cyanoacrylate. Erectile function was preserved during a 12-month follow-up. No patients with percutaneous direct puncture embolization for high-flow priapism have been reported previously. Percutaneous direct puncture embolization is a potentially useful and safe method for management of high-flow priapism.

  7. Percutaneous endoscopic colostomy of the left colon: a new technique for management of intractable constipation in children.

    PubMed

    Rawat, David J; Haddad, Munther; Geoghegan, Niamh; Clarke, Simon; Fell, John M

    2004-07-01

    The antegrade colonic enema is accepted as effective for management of intractable constipation in children when conventional bowel management has failed. This study describes experience with a new, minimally invasive technique, the distal antegrade colonic enema, which involves percutaneous endoscopic colostomy of the left colon. Fifteen children with refractory constipation and soiling who had radiographic evidence of megarectum and/or distal colonic delay were selected for the procedure. The junction of the descending and the sigmoid colon was identified colonoscopically, and the percutaneous endoscopic colostomy tube, through which antegrade distal colonic enema are administered, was inserted. Fourteen children underwent distal percutaneous endoscopic colostomy insertion. The median time required for the procedure was 30 minutes (20-50 minutes). Excluding one child (technical difficulties with percutaneous endoscopic colostomy placement), median post-procedural hospital stay was 4 days (2-27 days). Thirteen children were no longer soiling, and improvement in quality of life was reported at 2 months' follow-up. At 6 months' follow-up, 90% of children were clean during intervals between enemas. All children evaluated at 12 months' follow-up remained clean. Median duration of follow-up was 12.5 months (2-51 months). The distal percutaneous endoscopic colostomy is a simple alternative to established methods for delivery of antegrade enemas. It is less invasive and on reversal leaves only minor scarring.

  8. Novel nonsurgical left ventricular assist device and system.

    PubMed

    Misiri, Juna; DeSimone, Christopher V; Park, Soon J; Kushwaha, Sudhir S; Friedman, Paul A; Bruce, Charles J; Asirvatham, Samuel J

    2013-01-01

    Treatment options for advanced stages of congestive heart failure remain limited. Left ventricular assist devices (LVADs) have emerged as a means to support failing circulation. However, these devices are not without significant risk such as major open chest surgery. We utilized a novel approach for device placement at the aorto-left atria continuity as a site to create a conduit capable of accommodating a percutaneous LVAD system. We designed and developed an expandable nitinol based device for placement at this site to create a shunt between the LA and aorta. Our experiments support this anatomic location as an accessible and feasible site for accommodation of an entirely percutaneous LVAD. The novelty of this approach would bypass the left ventricle, and thereby minimize complications and morbidities associated with current LVAD placement. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. Friable but treatable: coronary artery dissections in Ehlers-Danlos syndrome.

    PubMed

    Zago, Alexandre C; Matte, Bruno S

    2013-01-01

    Vascular Ehlers-Danlos syndrome is a rare connective tissue disorder associated with arterial dissection or rupture. Percutaneous coronary intervention (PCI) is often critical in patients with this syndrome because their coronary arteries are prone to dissection, enhancing the risk of stent borders dissection when conventional stent deployment pressures are used. Coronary artery bypass graft (CABG) treatment for these patients may also raise concerns because the left internal mammary artery is probably friable. Therefore, coronary artery revascularization in vascular Ehlers-Danlos syndrome either using PCI or CABG is challenging due to the arteries friability. A small number of cases have been published describing the friability of the vessels and associated complications; nevertheless, the optimum treatment remains unclear. We report the case of a 54-year-old woman treated successfully with PCI and CABG in two different acute coronary syndrome episodes, in which specific technical issues related to both procedures were decisive. Copyright © 2011 Wiley Periodicals, Inc.

  10. Mitral valve replacement complicated by iatrogenic left ventricular outflow obstruction and paravalvular leak: case report and review of literature.

    PubMed

    Lee, Justin Z; Tey, Kai R; Mizyed, Ahmad; Hennemeyer, Charles T; Janardhanan, Rajesh; Lotun, Kapildeo

    2015-10-09

    Left ventricular outflow tract (LVOT) obstruction and paravalvular leak (PVL) are relatively uncommon, but are serious complications of prosthetic valve replacement. We present a case that displays the unique therapeutic challenges of treating a patient who developed both LVOT obstruction and mitral PVL after undergoing surgical aortic and mitral valve replacement (MVR). We also describe the use of alcohol septal ablation and albumin-glutaraldehyde (BioGlue) for septal ablation to percutaneously treat the patient's LVOT obstruction, followed by use of an Amplatzer vascular plug for percutaneous closure of an antero-medial mitral PVL associated with severe regurgitation. Percutaneous interventional management of these entities may be considered as an initial therapeutic option, especially in high-risk patients with significant morbidity and mortality of repeat surgical operations.

  11. Association between percutaneous hemodynamic support device and survival from cardiac arrest in the state of Michigan.

    PubMed

    Pressman, Andrew; Sawyer, Kelly N; Devlin, William; Swor, Robert

    2018-05-01

    The role of circulatory support in the post-cardiac arrest period remains controversial. Our objective was to investigate the association between treatment with a percutaneous hemodynamic support device and outcome after admission for cardiac arrest. We performed a retrospective study of adult patients with admission diagnosis of cardiac arrest or ventricular fibrillation (VF) from the Michigan Inpatient Database, treated between July 1, 2010, and June 30, 2013. Patient demographics, clinical characteristics, treatments, and disposition were electronically abstracted based on ICD-9 codes at the hospital level. Mixed-effects logistic regression models were fit to test the effect of percutaneous hemodynamic support device defined as either percutaneous left ventricular assist device (pLVAD) or intra-aortic balloon pump (IABP) on survival. These models controlled for age, sex, VF, myocardial infarction (MI), and cardiogenic shock with hospital modeled as a random effect. A total of 103 hospitals contributed 4393 patients for analysis, predominately male (58.8%) with a mean age of 64.1years (SD 15.5). On univariate analysis, younger age, male sex, VF as the initial rhythm, acute MI, percutaneous coronary intervention, percutaneous hemodynamic support device, and absence of cardiogenic shock were associated with survival to discharge (each p<0.001). Mixed-effects logistic regressions revealed use of percutaneous hemodynamic support device was significantly associated with survival among all patients (OR 1.8 (1.28-2.54)), and especially in those with acute MI (OR 1.95 (1.31-2.93)) or cardiogenic shock (OR 1.96 (1.29-2.98)). Treatment with percutaneous hemodynamic support device in the post-arrest period may provide left ventricular support and improve outcome. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Acute total left main stem occlusion treated with emergency percutaneous coronary intervention

    PubMed Central

    Mozid, A M; Sritharan, K; Clesham, G J

    2010-01-01

    Acute total occlusion of the left main stem (LMS) is a rare cause of myocardial infarction but carries a high risk of morbidity and mortality including presentation as sudden death. We describe the case of a 68-year-old woman who presented acutely with chest pain and ST segment elevation in lead aVR on her ECG suggestive of possible LMS occlusion. Emergency coronary angiography confirmed acute total LMS occlusion as well as an anomalous dominant right coronary artery. The patient underwent emergency percutaneous coronary intervention of the LMS with a good angiographic result and resolution of her symptoms. The patient was treated for acute left ventricular failure but made a gradual recovery and was discharged home 7 days after admission.

  13. Percutaneously implanted left ventricular assist device: establishing a program from implant to intensive care unit.

    PubMed

    Speiser, Bernadette S

    2011-01-01

    Cardiogenic shock is a critical disease process that claims lives every year. A new device on the market allows 2.5 L of cardiac output through the heart to assist in patient stabilization while attempting treatment options such as percutaneous coronary intervention to open closed coronary arteries.

  14. Percutaneous closure of a hemodynamically significant connection between the inferior vena cava and the left atrium.

    PubMed

    Wiebe, Jens; Rixe, Johannes; Nef, Holger

    2015-10-01

    A connection between the inferior vena cava (IVC) and the left atrium (LA) can occur as a rare complication after surgical atrial septum defect (ASD) repair. We demonstrate the first case of a percutaneous closure of this connection. A 67-year-old female was admitted to hospital due to exertional dyspnea. A history of a surgical ASD repair in 1960 and 1966 with a residual shunt was already known. Transesophageal echocardiography and a CT scan revealed a hemodynamically significant drainage of the IVC into the LA. This connection was successfully closed percutaneously with an AMPLATEZR Duct Occluder I (St. Jude Medical, St. Paul, MN). Post-procedural CT-scan and transthoracic echocardiography demonstrated a stable position and there was also no evidence of a residual shunt. The patient reported a significant reduction of exertional dyspnea. Percutaneous closure of an IVC to LA connection in this case was safe and feasible. The decision about which device is optimal must be made on an individual basis. © 2015 Wiley Periodicals, Inc.

  15. First magnetic resonance imaging-guided aortic stenting and cava filter placement using a polyetheretherketone-based magnetic resonance imaging-compatible guidewire in swine: proof of concept.

    PubMed

    Kos, Sebastian; Huegli, Rolf; Hofmann, Eugen; Quick, Harald H; Kuehl, Hilmar; Aker, Stephanie; Kaiser, Gernot M; Borm, Paul J A; Jacob, Augustinus L; Bilecen, Deniz

    2009-05-01

    The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. The guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.

  16. First Magnetic Resonance Imaging-Guided Aortic Stenting and Cava Filter Placement Using a Polyetheretherketone-Based Magnetic Resonance Imaging-Compatible Guidewire in Swine: Proof of Concept

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kos, Sebastian, E-mail: skos@gmx.d; Huegli, Rolf; Hofmann, Eugen

    The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. Themore » guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.« less

  17. [Late complication of selective renal arterial embolization after percutaneous surgery: renal "colic"].

    PubMed

    Savoie, Pierre-Henri; Lafolie, Trévor; Gabaudan, Charline; Biance, Nicolas; Avaro, Jean-Philippe; André, Marc; Bertrand, Serge; Balandraud, Paul

    2007-06-01

    Authors report a case of a 31 years old patient who eliminate a urinary stone which contains a platinium coil. Five years ago, this patient had a percutaneous nephrolithotomy. A persistent hematuria was successfully managed with angioembolization of a lower polar artery branch. One of the coils was deployed too distally. It was not efficient, it rolled itself up in the pseudoaneurysm cavity. Different physio pathological hypothesis are developed to explain this expulsion.

  18. Splenic injury during percutaneous nephrolithotomy.

    PubMed

    Thomas, Anil A; Pierce, Gregory; Walsh, R Matthew; Sands, Mark; Noble, Mark

    2009-01-01

    Injury to the spleen is a recognized complication during percutaneous renal access due to the close anatomical relationship of the spleen and the left kidney. However, transsplenic renal access is a rare complication of percutaneous nephrolithotomy and can also result in considerable morbidity, often requiring emergent splenectomy. We present our experience with splenic injury during percutaneous nephrolithotomy managed conservatively with the use of a collagen-thrombin hemostatic sealant (D-Stat; Vascular Solutions, Inc., Minneapolis, MN) after delayed removal of the nephrostomy tubes. The patient had an uneventful recovery and was discharged home on postoperative day 6. In select hemodynamically stable patients, nonoperative management with the adjunctive use of hemostatic sealants may be considered.

  19. PERCUTANEOUS RADIOFREQUENCY ASSISTED LIVER PARTITION WITH PORTAL VEIN EMBOLIZATION FOR STAGED HEPATECTOMY (PRALPPS).

    PubMed

    Giménez, Mariano E; Houghton, Eduardo J; Davrieux, C Federico; Serra, Edgardo; Pessaux, Patrick; Palermo, Mariano; Acquafresca, Pablo A; Finger, Caetano; Dallemagne, Bernard; Marescaux, Jacques

    2018-03-01

    When a major hepatic resection is necessary, sometimes the future liver remnant is not enough to maintain sufficient liver function and patients are more likely to develop liver failure after surgery. To test the hypothesis that performing a percutaneous radiofrecuency liver partition plus percutaneous portal vein embolization (PRALPPS) for stage hepatectomy in pigs is feasible. Four pigs (Sus scrofa domesticus) both sexes with weights between 25 to 35 kg underwent percutaneous portal vein embolization with coils of the left portal vein. By contrasted CT, the difference between the liver parenchyma corresponding to the embolized zone and the normal one was identified. Immediately, using the fusion of images between ultrasound and CT as a guide, radiofrequency needles were placed percutaneouslyand then ablated until the liver partition was complete. Finally, hepatectomy was completed with a laparoscopic approach. All animals have survived the procedures, with no reported complications. The successful portal embolization process was confirmed both by portography and CT. In the macroscopic analysis of the pieces, the depth of the ablation was analyzed. The hepatic hilum was respected. On the other hand, the correct position of the embolization material on the left portal vein could be also observed. "Percutaneous radiofrequency assisted liver partition with portal vein embolization" (PRALLPS) is a feasible procedure.

  20. Promotion of artery occlusion in dogs by percutaneous rotational atherectomy.

    PubMed

    Hou, Chuan-Ju; Zhang, Duan-Zhen; Wang, Qi-Guang; Cui, Chun-Sheng; Kuang, Li; Chen, Bing; Wang, Yang

    2014-07-01

    This study aims to offer experimental data and indirect evidences for the application of percutaneous rotational atherectomy to treat patent ductus arteriosus (PDA). Eleven dogs (6 male dogs and 5 female dogs; aged 14-20 months, with an average of 16.7±3.2 months; weight 20-25 kg, with an average of 22.7±2.5 kg) were enrolled in this study. The diameters of the left and right arteries ranged from 3.2 to 4.8 mm (average 3.9±0.6 mm) on percutaneous angiography. Percutaneous rotational atherectomy with proper rotablator (the size was 1-1.5 mm larger than the artery diameter) was performed in the arterial intima. After 4 weeks from percutaneous rotational atherectomy, arteriography was conducted to observe the changes in artery diameter. Then all dogs were sacrificed and the pathologic examination was conducted on the left and right axillary arteries. There were obvious changes with different degrees in 22 arteries, including 8 arteries with complete occlusion and 12 arteries with stenosis (≥2/3, 1/2, and 1/3 stenosis in 4, 4, and 4 arteries, respectively). The occlusion rate was 36.4% and the total effective rate was 90.9%. It was considered failure in other 2 arteries with <1/3 of stenosis. Percutaneous rotational atherectomy of arterial intima can promote the occlusion of arteries. This has provided a new choice for the treatment of PDA. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Surgical myocardial revascularization in patients with reduced systolic left ventricular function.

    PubMed

    Bruno, Piergiorgio; Iafrancesco, Mauro; Massetti, Massimo

    2018-04-20

    Surgical myocardial revascularization in patients with reduced left ventricular function has been a matter of debate for decades. Recently published 10-years extension follow-up of the STICH trial have conclusively demonstrated benefit of surgical myocardial revascularization in patients with significant coronary artery disease and low left ventricular ejection fraction. However, selection of patients for surgery remains challenging as well as decision to perform percutaneous rather than surgical revascularization in this class of patients. New evidence helped to clarify the role of preoperative patients' characteristics as risk factors for surgery and to identify those patients who may benefit the most from surgery. Focus of this review is to review epidemiology, aetiology and pathophysiology of coronary artery disease in patients with reduced left ventricular function, role of viability and results of observational and investigational studies on revascularization in patients with reduced left ventricular function with a particular emphasis on relative indication of coronary artery bypass grafting and percutaneous coronary intervention and the surgical implications of development of ischemic mitral regurgitation or ischemic left ventricular aneurysm.

  2. [Percutaneous nephrolithotomy by electrohydraulic shock wave].

    PubMed

    Hamao, T; Kuroko, K; Inoue, T; Ashida, H; Ishikawa, T

    1986-02-01

    Twelve patients underwent percutaneous nephrolithotomy in our hospital. Six of these patients had stone disintegration by electrohydraulic shock wave. The procedure was safe and effective for achieving rapid stone disintegration. Translocation of the stone fragments and central metal core of the probe left in the ureter were clinical problems. However, they passed spontaneously. Usefulness and problems of electrohydraulic lithotripsy were discussed.

  3. Percutaneous biliary approach as a successful rescue procedure after failed endoscopic therapy for drainage in advanced hilar tumors.

    PubMed

    Jang, Sung Ill; Hwang, Jin-Hyeok; Lee, Kwang-Hun; Yu, Jeong-Sik; Kim, Hee Wook; Yoon, Chang Jin; Lee, Yoon Suk; Paik, Kyu Hyun; Lee, Sang Hyub; Lee, Dong Ki

    2017-04-01

    Palliative endoscopic or percutaneous biliary drainage is used for unresectable advanced hilar cancer (HC). The best option for drainage in Bismuth type III or IV HC has not been established. The aims of this study are to identify factors predictive of endoscopic stenting failure and evaluate the effectiveness of rescue percutaneous stenting in patients with advanced HC. Data from 110 patients with inoperable advanced HC were retrospectively reviewed. All received bilateral self-expandable metallic stents. Patients were divided into three groups: I, successful initial endoscopic stenting; II, unsuccessful initial endoscopic stenting, followed by percutaneous stenting; and III, initial percutaneous stenting. We analyzed clinical results and radiologic tumor characteristics. Baseline characteristics and clinical outcomes of all groups were similar, except the hospital stay was longer in group III than group I. Technical success rate was higher in groups II and III (100%) than in group I (72.4%). The functional success rate, stent patency time, patient survival time, and complication rate were similar between groups. Endoscopic stenting failed because of guide-wire passage failure (n = 12) or stent passage failure (n = 7). The only factor significantly associated with endoscopic failure was a smaller left intrahepatic duct-common bile duct angle. As clinical outcomes were generally similar between approaches, percutaneous stenting is recommended for patients with Bismuth type III or IV advanced HC. Acute left intrahepatic duct-common bile duct angulation predicts endoscopic stenting failure. If endoscopic stenting fails, immediate conversion to the percutaneous approach is a necessary and effective rescue method. © 2016 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  4. Splenic Injury During Percutaneous Nephrolithotomy

    PubMed Central

    Thomas, Anil A.; Pierce, Gregory; Walsh, R. Matthew; Sands, Mark

    2009-01-01

    Background: Injury to the spleen is a recognized complication during percutaneous renal access due to the close anatomical relationship of the spleen and the left kidney. However, transsplenic renal access is a rare complication of percutaneous nephrolithotomy and can also result in considerable morbidity, often requiring emergent splenectomy. Methods: We present our experience with splenic injury during percutaneous nephrolithotomy managed conservatively with the use of a collagen-thrombin hemostatic sealant (D-Stat; Vascular Solutions, Inc., Minneapolis, MN) after delayed removal of the nephrostomy tubes. Results: The patient had an uneventful recovery and was discharged home on postoperative day 6. Conclusion: In select hemodynamically stable patients, nonoperative management with the adjunctive use of hemostatic sealants may be considered. PMID:19660224

  5. A clampless and sutureless aortic anastomosis technique using an endograft connector for aortoiliac occlusive disease in which the aorta cannot be clamped or sewn due to calcification or scarring.

    PubMed

    Papadimitriou, Dimitrios; Mayer, Dieter; Lachat, Mario; Pecoraro, Felice; Frauenfelder, Thomas; Pfammatter, Thomas; Ueda, Hideki; Donas, Konstantinos; Veith, Frank J; Rancic, Zoran

    2012-10-01

    Bypass surgery in aortoiliac or aortofemoral occlusive disease can be technically demanding and hazardous due to huge calcifications and/or patient co-morbidities. We report about mid-term results of a telescoping sutureless aortic anastomosis technique using endografts as connectors to address such challenging situations. This is a single-center experience (2004-2011) in seven patients (63 ± 6 years) requiring aortoiliac (three) or aortofemoral (four) bypass surgery. In six cases, an aortic stent graft was telescoped into the infrarenal aorta and partly deployed within the aorta and partly outside the aorta. In the first case, a bifurcated stent graft was deployed and the iliac legs were prolonged extra-anatomically with surgical grafts to reach the femoral bifurcation. In the following five cases, a tapered tubular stent graft was deployed through the aortic wall, landing inside a bifurcated surgical graft that was extra-anatomically connected to the iliac or femoral arteries. In the last case, which presented a hostile abdomen and high-risk for extensive surgery, a similar technique was used, but on the iliac artery level. In that case, an iliac stent graft re-loaded 'upside down' was deployed through the left common iliac wall, landing distally inside a hand-made 10 × 10 mm bifurcated surgical graft that was extra-anatomically connected to the left external iliac artery and to the right femoral artery. The distal anastomoses on the seven cases were performed either with running sutures (ten) or with VORTEC (four). Telescoping aortic and/or iliac anastomosis was successful in all patients. There was no perioperative mortality. One patient developed postoperative hyperperfusion of the left leg and necessitated fasciotomy. During a mean follow-up of 1.8 ± 2 years (minimum: 270 days, maximum: 7.1 years), all of the grafts remained patent and there was neither stent-graft migration nor stenosis on the level of the aortic or iliofemoral connection. One patient showed disease progression and required percutaneous transluminal angioplasty on the external iliac artery during follow-up. The uneventful perioperative course in these seven patients, with a follow-up of up to six years, underscores that this new technique can be considered in patients with aortoiliac or aortofemoral occlusive disease and in whom clamping and/or anastomosis is expected to be cumbersome or impossible.

  6. Massive Atenolol, Lisinopril, and Chlorthalidone Overdose Treated with Endoscopic Decontamination, Hemodialysis, Impella Percutaneous Left Ventricular Assist Device, and ECMO.

    PubMed

    Heise, C William; Beutler, David; Bosak, Adam; Orme, Geoffrey; Loli, Akil; Graeme, Kimberlie

    2015-03-01

    Overdose of cardiovascular medications is increasingly associated with morbidity and mortality. We present a case of substantial atenolol, chlorthalidone, and lisinopril overdose treated by multiple modalities with an excellent outcome. Aggressive medical intervention did not provide sufficient hemodynamic stability in this patient with refractory cardiogenic and distributive shock. Impella® percutaneous left ventricular assist device and extracorporeal membrane oxygenation provided support while the effects of the overdose subsided. We present concentrations demonstrating removal of atenolol with continuous venovenous hemodiafiltration. This is the first report of esophagogastroduo denoscopy decontamination of this overdose with a large pill fragment burden.

  7. Every Child Left Behind -- Addressing One Important Effect of Multiple Deployments

    DTIC Science & Technology

    2009-03-25

    St ra te gy Re se ar ch Pr oj ec t EVERY CHILD LEFT BEHIND – ADDRESSING ONE IMPORTANT EFFECT OF MULTIPLE DEPLOYMENTS BY LIEUTENANT COLONEL TYLER J...To) 4. TITLE AND SUBTITLE Every Child Left Behind – Addressing One Important Effect of Multiple Deployments 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c...Form 298 (Rev. 8-98) Prescribed by ANSI Std. Z39.18 USAWC STRATEGY RESEARCH PROJECT EVERY CHILD LEFT BEHIND – ADDRESSING ONE IMPORTANT EFFECT OF

  8. First in vivo evaluation of a flexible self-apposing left atrial appendage closure device in the canine model.

    PubMed

    Cheng, Yanping; Conditt, Gerard; Yi, Genghua; Tellez, Armando; Corcoran, Michael; Rousselle, Serge; Kaluza, Greg L; Granada, Juan F

    2015-07-01

    Aimed to evaluate the feasibility of deployment and healing response of a novel transcatheter left atrial appendage (LAA) occlusion device in the canine model LAA occlusion is proposed to reduce the risk of stroke in atrial fibrillation patients Transseptal puncture and device deployment was guided under fluoroscopy and transesophageal echocardiography (TEE) in five dogs. First, a distal cylindrical bulb occluder was released and secured to the appendage wall with hooks. Subsequently, a proximal sail was unfolded, covering the LAA ostium. Rotational angiography, TEE, and histology outcomes were assessed 30 days following implantation Pre-operative TEE revealed the mean diameter of the LAA ostium to be 17.2 ± 1.6 mm with a depth of 18.5 ± 1.7 mm. The landing zone for the distal bulb was measured to be 12.8 ± 1.3 mm. The mean bulb diameter at implant was 16.8 ± 1.8 mm. Post-operative TEE showed adequate positioning and successful LAA occlusion with all implanted devices. Pericardial effusion requiring pericardiocentesis was seen in one animal following device implantation. At 30 days, TEE revealed full occlusion of all LAA ostia with the exception of a minimal peri-device leak (<3 mm) observed in one animal. No pericardial effusion or device-related thrombus formation was found at termination. Histological analysis confirmed circumferential occlusion of all appendages and complete neointimal coverage on the luminal aspect of the occluder The percutaneous delivery of a novel self-positioning LAA occlusion device is feasible and safe in a canine model. At 30 days, all devices displayed complete healing and occlusion of the LAA without any device related adverse events. © 2015 Wiley Periodicals, Inc.

  9. Effects of liraglutide on left ventricular function in patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention.

    PubMed

    Chen, Wei Ren; Hu, Shun Ying; Chen, Yun Dai; Zhang, Ying; Qian, Geng; Wang, Jing; Yang, Jun Jie; Wang, Zhi Feng; Tian, Feng; Ning, Qing Xiu

    2015-11-01

    Several studies have shown that exenatide protects against ischemia-reperfusion injury and improves cardiac function in patients with acute ST-segment elevation myocardial infarction (STEMI). The effects of liraglutide, a glucagon-like peptide-1 analogue, on STEMI patients remain unclear. We planned to evaluate the effects of liraglutide on left ventricular function after primary percutaneous coronary intervention for STEMI. A total of 92 patients were randomized 1:1 to receive either liraglutide or placebo for 7 days. Study treatment was commenced 30 minutes before intervention (1.8 mg) and maintained for 7 days after the procedure (0.6 mg for 2 days, 1.2 mg for 2 days, followed by 1.8 mg for 3 days). Eighty-five patients completed the trial. Transthoracic echocardiography was used to assess left ventricular function. At 3 months, the primary end point, a difference in change of left ventricular ejection fraction between the two groups was +4.1% (95% CI +1.1% to +6.9%) (P < .001). There was a tendency for a lower rate of no-reflow in liraglutide group that did not reach statistical significance (7% vs control group 15%, P = .20). Liraglutide could significantly improve stress hyperglycemia (P < .05). In addition, liraglutide elicited favorable changes in markers of inflammation and endothelial function. A short 7-day course of liraglutide in STEMI patients treated with primary percutaneous coronary intervention is associated with mild improvement in left ventricular ejection fraction at 3 months. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Systemic Hypertension and Transient Ischemic Attack in a 6-Year-Old Girl with Fibromuscular Dysplasia Treated with Percutaneous Angioplasty

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Foa-Torres, Gustavo; Ganame, Javier, E-mail: javier.ganame@uzleuven.b; Juaneda, Ernesto

    We describe a 6-year-old girl with arterial hypertension secondary to fibromuscular dysplasia with stenoses of both renal arteries and transient ischemic attack due to extracranial right internal carotid artery subtotal occlusion as well as left internal carotid artery stenosis. She was treated with percutaneous angioplasty of both renal and both carotid arteries.

  11. Prospective analysis of percutaneous endoscopic colostomy at a tertiary referral centre.

    PubMed

    Baraza, W; Brown, S; McAlindon, M; Hurlstone, P

    2007-11-01

    Percutaneous endoscopic colostomy (PEC) is an alternative to surgery in selected patients with recurrent sigmoid volvulus, recurrent pseudo-obstruction or severe slow-transit constipation. A percutaneous tube acts as an irrigation or decompressant channel, or as a mode of sigmoidopexy. This prospective study evaluated the safety and efficacy of this procedure at a single tertiary referral centre. Nineteen patients with recurrent sigmoid volvulus, ten with idiopathic slow-transit constipation and four with pseudo-obstruction underwent PEC. The tube was left in place indefinitely in those with recurrent sigmoid volvulus or constipation, whereas in patients with pseudo-obstruction it was left in place for a variable period of time, depending on symptoms. Thirty-five procedures were performed in 33 patients. Three patients developed peritonitis, of whom one died, and ten patients had minor complications. Symptoms resolved in 26 patients. This large prospective study has confirmed the value of PEC in the treatment of recurrent sigmoid volvulus and pseudo-obstruction in high-risk surgical patients. Copyright (c) 2007 British Journal of Surgery Society Ltd.

  12. Percutaneous management of urolithiasis during pregnancy.

    PubMed

    Kavoussi, L R; Albala, D M; Basler, J W; Apte, S; Clayman, R V

    1992-09-01

    A total of 6 pregnant women with obstructing urinary calculi was managed by percutaneous nephrostomy drainage placed under ultrasound guidance with the patient under local anesthesia. All patients initially had relief of acute obstruction. However, occlusion of the percutaneous nephrostomy tubes with debris necessitated tube changes in 5 of 6 patients. In 2 patients recurrent nephrostomy tube obstruction, fever and pain led to percutaneous stone removal during pregnancy. In the remaining 4 patients the nephrostomy tubes were left indwelling through delivery. During the postpartum period 3 patients successfully underwent ureteroscopic stone extraction and 1 passed the stone spontaneously. Bacteriuria developed in each patient despite the use of preventive antibiotics. All 6 women had uncomplicated vaginal deliveries of healthy newborns and are currently asymptomatic with no evidence of obstruction. Percutaneous drainage of an acutely obstructed kidney in a pregnant woman is an effective temporizing alternative to ureteral stent placement until definitive treatment can be performed.

  13. Transcatheter Embolization of a Coronary Fistula Originating from the Left Anterior Descending Artery by Using N-Butyl 2-Cyanoacrylate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karagoz, Tevfik; Celiker, Alpay; Cil, Barbaros

    In this report, we describe a successful percutaneous transcatheter n-butyl 2-cyanoacrylate embolization of a coronary fistula originating from the left anterior descending artery in an adolescent with unexpected recurrent attacks of myocardial ischemia.

  14. Rupture of the Renal Artery After Cutting Balloon Angioplasty in a Young Woman With Fibromuscular Dysplasia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oguzkurt, Levent, E-mail: loguzkurt@yahoo.com; Tercan, Fahri; Gulcan, Oner

    2005-04-15

    A 24-year-old woman with uncontrollable high blood pressure for 3 months had significant stenosis of the left renal artery caused by fibromuscular dysplasia (FMD). The lesion was resistant to percutaneous transluminal angioplasty at 18 atm with a semicompliant balloon. Angioplasy with a 6 x 10 mm cutting balloon (CB) caused rupture of the artery. Low-pressure balloon inflation decreased but did not stop the leak. An attempt to place a stent-graft (Jostent; Jomed, Rangendingen, Germany) failed, and a bare, 6-mm balloon-expandable stent (Express SD; Boston Scientific, MN) was deployed to seal the leak, which had decreased considerably after long-duration balloon inflation.more » The bleeding continued, and the patient underwent emergent surgical revascularization of the renal artery with successful placement of a 6-mm polytetrafluoroethylene bypass graft. CBs should be used very carefully in the treatment of renal artery stenosis, particularly in patients with FMD.« less

  15. Guide Catheter Extension Device Is Effective in Renal Angioplasty for Severely Calcified Lesions.

    PubMed

    Sugimoto, Takeshi; Nomura, Tetsuya; Hori, Yusuke; Yoshioka, Kenichi; Kubota, Hiroshi; Miyawaki, Daisuke; Urata, Ryota; Kikai, Masakazu; Keira, Natsuya; Tatsumi, Tetsuya

    2017-05-23

    BACKGROUND The GuideLiner catheter extension device is a monorail-type "Child" support catheter that facilitates coaxial alignment with the guide catheter and provides an appropriate back-up force. This device has been developed in the field of coronary intervention, and now is becoming widely applied in the field of endovascular treatment. However, there has been no report on the effectiveness of the guide catheter extension device in percutaneous transluminal renal angioplasty (PTRA). CASE REPORT We encountered a case of atherosclerotic subtotal occlusion at the ostium of the left renal artery. Due to the severely calcified orifice and weaker back-up force provided by a JR4 guide catheter, we could not pass any guidewires through the target lesion. Therefore, we introduced a guide catheter extension device, the GuideLiner catheter, through the guide catheter and achieved good guidewire maneuverability. We finally deployed 2 balloon-expandable stents and successfully performed all PTRA procedures. CONCLUSIONS The guide catheter extension device can be effective in PTRA for severely calcified subtotal occlusion.

  16. The safety and feasibility of guidezilla catheter in complex coronary interventions and an observational study.

    PubMed

    Ma, Jianying; Hou, Lei; Qian, Juying; Ge, Lei; Zhang, Feng; Chang, Shufu; Xu, Rende; Qin, Qing; Ge, Junbo

    2017-10-01

    The monorail Guidezilla guide extension catheter was designed to provide additional backup and facilitate device delivery in percutaneous coronary intervention (PCI) for complex coronary anatomy such as chronic total occlusion (CTO), extreme vessel tortuosity, diseased bypass grafts, and anomalous coronary arteries, among others.The present retrospective, single-center study included 188 consecutive patients who underwent PCI using the Guidezilla catheter from March 2015 to August 2016. Study outcomes were rates of target lesion crossing success, procedural success, and complications.The Guidezilla catheter was used most commonly in PCI of CTOs (45%) and heavy proximal calcification (37%), followed by tortuosity (10%), previously deployed proximal stents (4%), and coronary artery anomaly (4%). The right coronary artery (48%) was most commonly intervened followed by the left ascending (35%) and left circumflex (17%) arteries. Rates of target lesion crossing success and procedural success were both 99%, with one device-related periprocedural complication, namely proximal vessel dissection secondary to deep insertion which was successfully treated with stent implantation. Ninety percent of PCI were performed and completed successfully by radial access.In a single center with experienced operators, the use of the Guidezilla guide extension catheter in PCI of complex coronary anatomy performed mostly via radial artery access appeared safe and efficacious, and greatly facilitated device delivery.

  17. The safety and feasibility of guidezilla catheter in complex coronary interventions and an observational study

    PubMed Central

    Ma, Jianying; Hou, Lei; Qian, Juying; Ge, Lei; Zhang, Feng; Chang, Shufu; Xu, Rende; Qin, Qing; Ge, Junbo

    2017-01-01

    Abstract The monorail GuidezillaTM guide extension catheter was designed to provide additional backup and facilitate device delivery in percutaneous coronary intervention (PCI) for complex coronary anatomy such as chronic total occlusion (CTO), extreme vessel tortuosity, diseased bypass grafts, and anomalous coronary arteries, among others. The present retrospective, single-center study included 188 consecutive patients who underwent PCI using the Guidezilla catheter from March 2015 to August 2016. Study outcomes were rates of target lesion crossing success, procedural success, and complications. The Guidezilla catheter was used most commonly in PCI of CTOs (45%) and heavy proximal calcification (37%), followed by tortuosity (10%), previously deployed proximal stents (4%), and coronary artery anomaly (4%). The right coronary artery (48%) was most commonly intervened followed by the left ascending (35%) and left circumflex (17%) arteries. Rates of target lesion crossing success and procedural success were both 99%, with one device-related periprocedural complication, namely proximal vessel dissection secondary to deep insertion which was successfully treated with stent implantation. Ninety percent of PCI were performed and completed successfully by radial access. In a single center with experienced operators, the use of the Guidezilla guide extension catheter in PCI of complex coronary anatomy performed mostly via radial artery access appeared safe and efficacious, and greatly facilitated device delivery. PMID:28984768

  18. A case report of percutaneous endoscopic gastrostomy left-side gastropexy to resolve a recurrent gastric dilatation in a dog previously treated with right-side gastropexy for gastric dilatation volvulus.

    PubMed

    Spinella, Giuseppe; Cinti, Filippo; Pietra, Marco; Capitani, Ombretta; Valentini, Simona

    2014-12-01

    A 6-year-old, large-breed, female dog was evaluated for gastric dilatation (GD). The dog was affected by GD volvulus, which had been surgically treated with gastric derotation and right incisional gastropexy. Recurrence of GD appeared 36 hours after surgery. The dilatation was immediately treated with an orogastric probe but still recurred 4 times. Therefore, a left-side gastropexy by percutaneous endoscopic gastrostomy (PEG) was performed to prevent intermittent GD. After PEG tube placement, the patient recovered rapidly without side effects. Several techniques of gastropexy have been described as a prophylactic method for gastric dilatation volvulus, but to the authors' knowledge, this is the first report of left-sided PEG gastropexy performed in a case of canine GD recurrence after an incisional right gastropexy. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Transient severe left ventricular dysfunction following percutaneous patent ductus arteriosus closure in an adult with bicuspid aortic valve: A case report

    PubMed Central

    HWANG, HUI-JEONG; YOON, KYUNG LIM; SOHN, IL SUK

    2016-01-01

    The present study reported the case of a 60-year-old female with patent ductus arteriosus (PDA) and a bicuspid aortic valve, who presented with transient severe left ventricular (LV) dysfunction following percutaneous closure of PDA, as identified by speckle tracking analysis. Transient LV dysfunction following PDA closure has previously been reported; however, severe LV dysfunction is rare. In the present case, the combination of a large PDA size, large amount of shunting, LV remodeling and bicuspid aortic valve may have induced serious deterioration of LV function following PDA closure. Furthermore, speckle-tracking echocardiography may be useful in the estimation of functional alterations in the myocardium of the LV following PDA closure. The observations detailed in the present study may improve the understanding of the pathophysiology and myocardial patterns of transient left ventricular dysfunction following PDA closure in adult humans. PMID:26998021

  20. Transient severe left ventricular dysfunction following percutaneous patent ductus arteriosus closure in an adult with bicuspid aortic valve: A case report.

    PubMed

    Hwang, Hui-Jeong; Yoon, Kyung Lim; Sohn, Il Suk

    2016-03-01

    The present study reported the case of a 60-year-old female with patent ductus arteriosus (PDA) and a bicuspid aortic valve, who presented with transient severe left ventricular (LV) dysfunction following percutaneous closure of PDA, as identified by speckle tracking analysis. Transient LV dysfunction following PDA closure has previously been reported; however, severe LV dysfunction is rare. In the present case, the combination of a large PDA size, large amount of shunting, LV remodeling and bicuspid aortic valve may have induced serious deterioration of LV function following PDA closure. Furthermore, speckle-tracking echocardiography may be useful in the estimation of functional alterations in the myocardium of the LV following PDA closure. The observations detailed in the present study may improve the understanding of the pathophysiology and myocardial patterns of transient left ventricular dysfunction following PDA closure in adult humans.

  1. Dangerous liaison: successful percutaneous edge-to-edge mitral valve repair in patients with end-stage systolic heart failure can cause left ventricular thrombus formation.

    PubMed

    Orban, Martin; Braun, Daniel; Sonne, Carolin; Orban, Mathias; Thaler, Raffael; Grebmer, Christian; Lesevic, Hasema; Schömig, Albert; Mehilli, Julinda; Massberg, Steffen; Hausleiter, Jörg

    2014-06-01

    To evaluate the characteristics and clinical outcome of patients with new formation of left ventricular (LV) thrombus after percutaneous edge-to-edge mitral valve repair. Between 2009 and 2012 we intended to treat 150 patients with severe mitral regurgitation (MR) with percutaneous edge-to-edge mitral valve repair in our centre. Post-procedural transthoracic echocardiographic examinations scheduled during the hospital stay revealed the new formation of LV thrombi in three out of 150 patients. All three patients suffered from end-stage systolic heart failure with a LV ejection fraction (LVEF) below 20% and were successfully treated in terms of MR reduction (reduction of at least two MR grades). No thrombus formation was observed in patients with a LVEF >20% treated in our centre (a total of 136 patients). The frequency of new LV thrombus formation in the cohort of patients with a LVEF ≤20% treated in our centre was 21% (three out of 14 patients). New formation of LV thrombus was detected in patients with severely depressed LVEF (≤20%) after successful reduction of MR following percutaneous edge-to-edge mitral valve repair. This phenomenon could be a play of chance, but percutaneous edge-to-edge mitral valve repair using the MitraClip¨ system is a new procedure. Special care is needed when performing new procedures, and the unexpected post-procedural finding of LV thrombus formation in approximately 20% in this cohort is worth reporting.

  2. Design and principle of operation of the HeartMate PHP (percutaneous heart pump).

    PubMed

    Van Mieghem, Nicolas M; Daemen, Joost; den Uil, Corstiaan; Dur, Onur; Joziasse, Linda; Maugenest, Anne-Marie; Fitzgerald, Keif; Parker, Chris; Muller, Paul; van Geuns, Robert-Jan

    2018-02-20

    The HeartMate PHP (percutaneous heart pump) is a second-generation transcatheter axial flow circulatory support system. The collapsible catheter pump is inserted through a 14 Fr sheath, deployed across the aortic valve expanding to 24 Fr and able to deliver up to 5 L/min blood flow at minimum haemolytic risk. As such, this device may be a valuable adjunct to percutaneous coronary intervention (PCI) of challenging lesions in high-risk patients or treatment of cardiogenic shock. This technical report discusses: (i) the HeartMate PHP concept, (ii) the implantation technique, (iii) the haemodynamic performance in an in vitro cardiovascular flow testing set-up, and (iv) preliminary clinical experience. An update on the device, produced by St. Jude Medical/Abbott Laboratories, can be found in the Appendix.

  3. ENDOSCOPIC ULTRASOUND-GUIDED FINE-NEEDLE ASPIRATION IN THE DIAGNOSIS OF ADRENAL METASTASIS IN A HIGH-RISK POPULATION.

    PubMed

    Zhang, Catherine D; Erickson, Dana; Levy, Michael J; Gleeson, Ferga C; Salomao, Diva R; Delivanis, Danae A; Bancos, Irina

    2017-12-01

    While the left adrenal gland is readily accessible via endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA), data regarding the utility of EUS-FNA in the diagnosis of adrenal lesions remain limited. We aimed to ( 1) describe the clinical context, adverse event rate, and diagnostic performance of EUS-FNA, and ( 2) compare the safety profile and diagnostic accuracy of EUS-FNA with percutaneous adrenal biopsy. Single-center, retrospective cohort study. Medical records of patients who underwent adrenal EUS-FNA from 2005-2016 were reviewed. Biopsy outcomes were evaluated using a predefined reference standard. Results were compared to patients who underwent percutaneous biopsy (n = 419; 1994-2014) at the same institution. A total of 121 patients underwent EUS-FNA of 122 adrenal lesions (left [n = 121]; right [n = 1]; mean lesion size, 1.8 cm). Cytology was positive for malignancy in 35 (29%), suspicious for malignancy in 1 (1%), atypical in 1 (1%), negative for malignancy in 81 (66%), and nondiagnostic in 4 (3%). No adverse events were reported. EUS-FNA diagnosed metastasis with a sensitivity of 100%, specificity of 97.4%, positive predictive value of 91.7%, and negative predictive value of 100%. When compared to percutaneous biopsy, lesion size (1.8 cm vs. 3.7 cm; P<.001) and biopsy site (99% vs. 62% left adrenal; P<.001) were significantly different. EUS-FNA adverse event rate was lower than percutaneous biopsy (0% vs. 4%; P = .024), but nondiagnostic rates were similar (3.3% vs. 4.8%; P = .48). EUS-FNA is a sensitive technique to sample adrenal lesions in patients at high risk for adrenal metastasis with fewer adverse events compared to percutaneous biopsy. CI = confidence interval CT = computed tomography EUS-FNA = endoscopic ultrasound-guided fine-needle aspiration NPV = negative predictive value PPV = positive predictive value TUS = transabdominal ultra-sound.

  4. The influence of percutaneous closure of patent ductus arteriosus on left ventricular size and function: a prospective study using two- and three-dimensional echocardiography and measurements of serum natriuretic peptides.

    PubMed

    Eerola, Anneli; Jokinen, Eero; Boldt, Talvikki; Pihkala, Jaana

    2006-03-07

    We aimed to evaluate the effect of percutaneous closure of patent ductus arteriosus (PDA) on left ventricular (LV) hemodynamics. Today, most PDAs are closed percutaneously. Little is known, however, about hemodynamic changes after the procedure. Of 37 children (ages 0.6 to 10.6 years) taken to the catheterization laboratory for percutaneous PDA closure, the PDA was closed in 33. Left ventricular diastolic and systolic dimensions, volumes, and function were examined by two-dimensional (2D) and three-dimensional (3D) echocardiography and serum concentrations of natriuretic peptides measured before PDA closure, on the following day, and 6 months thereafter. Control subjects comprised 36 healthy children of comparable ages. At baseline, LV diastolic diameter measured >+2 SD in 5 of 33 patients. In 3D echocardiography, a median LV diastolic volume measured 54.0 ml/m2 in the control subjects and 58.4 ml/m2 (p < 0.05) in the PDA group before closure and 57.2 ml/m2 (p = NS) 6 months after closure. A median N-terminal brain natriuretic peptide (pro-BNP) concentration measured 72 ng/l in the control group and 141 ng/l in the PDA group before closure (p = 0.001) and 78.5 ng/l (p = NS) 6 months after closure. Patients differed from control subjects in indices of LV systolic and diastolic function at baseline. By the end of follow-up, all these differences had disappeared. Even in the subgroup of patients with normal-sized LV at baseline, the LV diastolic volume decreased significantly during follow-up. Changes in LV volume and function caused by PDA disappear by 6 months after percutaneous closure. Even the children with normal-sized LV benefit from the procedure.

  5. Role of percutaneous veno-arterial extracorporeal membrane oxygenation as bridge to left ventricular assist device.

    PubMed

    Toda, Koichi; Fujita, Tomoyuki; Seguchi, Osamu; Yanase, Masanobu; Nakatani, Takeshi

    2018-03-01

    Percutaneous veno-arterial extracorporeal membrane oxygenation (VA-ECMO) provides emergency circulatory support for cardiogenic shock patients and is used as a bridge to a left ventricular assist device (LVAD). The purpose of this study was to determine risk factors for LVAD implantation in patients who required percutaneous VA-ECMO as a bridge to long-term LVAD. We retrospectively investigated 32 consecutive LVAD patients who required percutaneous VA-ECMO as a bridge to long-term LVAD. Twenty-nine patients (91%) were intubated, and their serum creatinine and total bilirubin levels before LVAD implantation were 2.1 ± 2.0 and 3.7 ± 3.7 mg/dl, respectively. Patients were supported by LVAD for 495 ± 393 days, during which 15 died, 6 recovered native cardiac functions and LVAD was explanted, and 11 underwent heart transplantation. Multivariate logistic regression analysis revealed that a preoperative left ventricular end-diastolic diameter (LVDd) ≤54 mm was a significant predictor of 90-day mortality after LVAD implantation (OR 13.64; 95% CI 1.081-172.0; p = 0.0433) and freedom from death during LVAD support was significantly worse in patients with an LVDd ≤54 mm. Furthermore, preoperative LVDd was positively correlated with postoperative right ventricular stroke work index (r = 0.739, p < 0.0001) and patients with an LVDd ≤54 mm had significantly worse postoperative right ventricular, renal, and hepatic functions. We demonstrated that percutaneous VA-ECMO could be utilized as a bridge to long-term LVAD in selected patients. Our results suggest that preoperative LVDd is a useful predictor of mortality and right ventricular function after LVAD implantation in patients requiring VA-ECMO, in whom assessment of right ventricular function is challenging.

  6. Percutaneous bail-out treatment of vein graft rupture with a polytetrafluoroethylene-covered stent.

    PubMed

    Pavlidis, Antonios N; Karamasis, Grigorios V; Clapp, Brian R

    2013-12-01

    Vessel perforation is an undesirable and life-threatening complication during vein graft angioplasty. We report on a case of vein graft rupture during angioplasty, which was successfully managed with deployment of a polytetrafluoroethylene-covered stent.

  7. Cost-effectiveness of percutaneous coronary intervention with drug-eluting stents versus bypass surgery for patients with 3-vessel or left main coronary artery disease: final results from the Synergy Between Percutaneous Coronary Intervention With TAXUS and Cardiac Surgery (SYNTAX) trial.

    PubMed

    Cohen, David J; Osnabrugge, Ruben L; Magnuson, Elizabeth A; Wang, Kaijun; Li, Haiyan; Chinnakondepalli, Khaja; Pinto, Duane; Abdallah, Mouin S; Vilain, Katherine A; Morice, Marie-Claude; Dawkins, Keith D; Kappetein, A Pieter; Mohr, Friedrich W; Serruys, Patrick W

    2014-09-30

    The Synergy Between Percutaneous Coronary Intervention With TAXUS and Cardiac Surgery (SYNTAX) trial demonstrated that in patients with 3-vessel or left main coronary artery disease, coronary artery bypass graft surgery (CABG) was associated with a lower rate of cardiovascular death, myocardial infarction, stroke, or repeat revascularization compared with percutaneous coronary revascularization with drug-eluting stents (DES-PCI)). The long-term cost-effectiveness of these strategies is unknown. Between 2005 and 2007, 1800 patients with left main or 3-vessel coronary artery disease were randomized to CABG (n=897) or DES-PCI (n=903). Costs were assessed from a US perspective, and health state utilities were evaluated with the EuroQOL questionnaire. A patient-level microsimulation model based on the 5-year in-trial data was used to extrapolate costs, life expectancy, and quality-adjusted life expectancy over a lifetime horizon. Although initial procedural costs were $3415 per patient lower with CABG, total hospitalization costs were $10 036 per patient higher. Over the next 5 years, follow-up costs were higher with DES-PCI as a result of more frequent hospitalizations, revascularization procedures, and higher medication costs. Over a lifetime horizon, CABG remained more costly than DES-PCI, but the incremental cost-effectiveness ratio was favorable ($16 537 per quality-adjusted life-year gained) and remained <$20 000 per quality-adjusted life-year in most bootstrap replicates. Results were consistent across a wide range of assumptions about the long-term effect of CABG versus DES-PCI on events and costs. In patients with left main disease or a SYNTAX score ≤22, however, DES-PCI was economically dominant compared with CABG, although these findings were less certain. For most patients with 3-vessel or left main coronary artery disease, CABG is a clinically and economically attractive revascularization strategy compared with DES-PCI. However, among patients with less complex disease, DES-PCI may be preferred on both clinical and economic grounds. www.clinicaltrials.gov. Unique identifier: NCT00114972. © 2014 American Heart Association, Inc.

  8. Percutaneous left atrial appendage occlusion – treatment outcomes and 6 months of follow-up – a single-center experience

    PubMed Central

    Karczewski, Michał; Skowronek, Radomir; Burysz, Marian; Fischer, Marcin; Anisimowicz, Lech; Demkow, Marcin; Konka, Marek; Ogorzeja, Wojciech

    2016-01-01

    Aim To present the results of treatment and evaluate 6 months of follow-up in a group of patients with non-valvular atrial fibrillation, who underwent the procedure of percutaneous left atrial appendage occlusion (PLAAO). Material and methods Percutaneous left atrial appendage occlusion was performed in 34 patients with non-valvular atrial fibrillation and contraindications for oral anticoagulation therapy. The risk of thromboembolic and bleeding complications was determined based on the CHA2DS2VASc and HAS-BLED scales. The Amplatzer Amulet system from St. Jude Medical was used. On the first postoperative day, all patients were started on double antiplatelet therapy with 75 mg/day of acetylsalicylic acid (ASA) and 75 mg/day of clopidogrel (CLO). On the 30th postoperative day, the efficacy of the antiplatelet therapy was assessed with impedance aggregometry using a Multiplate analyzer (Roche). Echocardiographic examinations were performed intraoperatively and on the first postoperative day; subsequently, follow-up examinations were conducted 1 and 6 months after the implantation. Results In all patients, proper occluder position was observed throughout the follow-up. No leakage or thrombi around the implants were found. No strokes or bleeding complications associated with the antiplatelet therapy were observed. Multiplate assessment of platelet activity was conducted in 20 out of 34 patients. The efficacy of ASA treatment was demonstrated in all patients; no response to clopidogrel treatment was observed in 5 out of 20 patients. One patient suffered from cardiac tamponade, which required the performance of full sternotomy. Local complications (hematomas of the inguinal region) were observed in 3 patients. One of the patients died for reasons unrelated to the procedure. Conclusions Percutaneous left atrial appendage occlusion is an effective procedure in patients with non-valvular atrial fibrillation and contraindications for chronic anticoagulation therapy. Further observation is necessary to evaluate the longterm results. PMID:27516780

  9. Percutaneous CT-Guided Treatment of Osteochondritis Dissecans of the Sacroiliac Joint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Becce, Fabio, E-mail: fabio.becce@chuv.ch; Mouhsine, Elyazid; Mosimann, Pascal John

    2012-08-15

    Osteochondritis dissecans (OCD) is a joint disorder that affects the articular cartilage and subchondral bone, most commonly at the knee. OCD of the sacroiliac joint is extremely rare. Management of OCD remains controversial, and surgery is often needed, especially when conservative treatment fails. We present a rare case of OCD involving the left sacroiliac joint successfully treated by percutaneous computed tomography-guided retrograde drilling and debridement.

  10. Percutaneous transvenous mitral commissurotomy in mitral stenosis and left atrial appendage clot patients in special conditions: Hospital-based study.

    PubMed

    Rajbhandari, Rajib; Malla, Rabi; Maskey, Arun; Bhatta, Yadav; Limbu, Yubraj; Sharma, Ranjit; Singh, Satish; Adhikari, Chandramani; Mishra, Sundeep

    The percutaneous transvenous mitral commissurotomy is an important procedure for the treatment of mitral stenosis. A lot of mitral stenosis cases have left atrial appendage clot which precludes the patient from the benefit of this procedure. The aim of the study was to study the feasibility and safety of the procedure in a patient with appendage clot in the setup of certain urgent conditions. All cases of mitral stenosis with significant dyspnea and mitral valve area <1.5cm 2 with left atrial appendage clot and a condition which would preclude the patient from continuing on anticoagulation and needed urgent intervention were included in the study. From January 2011 to December 2013, twenty patients coming to Shahid Gangalal National Heart Centre, Kathmandu were selected for the procedure with conventional sampling technique. Informed written consent was obtained from the patients explaining all possible complications. The approval of the study was taken from the ethical committee of the hospital. Mean mitral valve area increased from 0.90cm 2 (SD±0.14) to 1.5cm 2 (SD±0.21) (p=0.02). Left atrial mean pressure decreased from mean of 20 to 10mmHg. Subjective improvement was reported in all. All of the patients had fulfilled criteria for successful PTMC. There was no mortality during hospital stay or in one-week follow-up period. There were no neurological complications or any need for emergency surgery. The immediate result of percutaneous transvenous mitral commissurotomy in selected cases of mitral stenosis with left atrial appendage clot is safe and acceptable in certain urgent situations in experienced hands. Copyright © 2016. Published by Elsevier B.V.

  11. Feasibility and efficacy of the 2.5 L and 3.8 L impella percutaneous left ventricular support device during high-risk, percutaneous coronary intervention in patients with severe aortic stenosis.

    PubMed

    Spiro, Jon; Venugopal, Vinod; Raja, Yogesh; Ludman, Peter F; Townend, Jonathan N; Doshi, Sagar N

    2015-05-01

    Assessment of the feasibility and outcomes of the 2.5 L and 3.8 L Impella cardiac pump in patients with severe aortic stenosis (AS) and left ventricular impairment undergoing percutaneous revascularization (PCI) with or without balloon aortic valvuloplasty (BAV). We reviewed the clinical and procedural findings from a consecutive series of unselected patients with severe AS who underwent PCI during Impella support. In addition, we describe novel "balloon-assist" techniques that allowed implantation of Impella into the left ventricle (LV) when initial unassisted attempts failed. Five patients with severe AS were identified (four males, age 78.2 years, aortic valve area (AVA) 0.6 cm(2) , left ventricular ejection fraction (LVEF) 24 ± 5%, mean Society of Thoracic Surgeons (STS) mortality 11% (range 3-17%)). The Impella catheter traversed the aortic valve (AV) unassisted in only one patient, with four cases requiring balloon-assist techniques. All patients underwent planned revascularisation; mean procedure time 177 min (range 135-252 min), mean number of stents 3.4 (range 1-8), with three patients requiring rotational atherectomy. All procedures were well tolerated, with absence of arrhythmia, hypotension, pulmonary edema, stroke, or myocardial infarction. One patient died 48 hr post-PCI of multi-organ failure. The four remaining patients were well at 30 days. Implantation of the 2.5 and 3.8 L Impella appears feasible in patients with severe AS and left ventricle (LV) impairment. A balloon-assist technique may be used to facilitate device implantation when initial unassisted attempts fail. Improved hemodynamic stability may enhance the tolerability of lengthy and complex procedures. © 2014 Wiley Periodicals, Inc.

  12. Percutaneous Ventricular Assist Devices: New Deus Ex Machina?

    PubMed Central

    Arroyo, Diego; Cook, Stéphane

    2011-01-01

    The development of ventricular assist devices has broadened the means with which one can treat acute heart failure. Percutaneous ventricular assist devices (pVAD) have risen from recent technological advances. They are smaller, easier, and faster to implant, all important qualities in the setting of acute heart failure. The present paper briefly describes the functioning and assets of the most common devices used today. It gives an overview of the current evidence and indications for left ventricular assist device use in cardiogenic shock and high-risk percutaneous coronary intervention. Finally, extracorporeal life support devices are dealt with in the setting of hemodynamic support. PMID:22091361

  13. Rapid guiding catheter swapping for management of rupture during percutaneous venoplasty for idiopathic occlusion of superior vena cava.

    PubMed

    Pandit, Bhagya Narayan; Chaturvedi, Vivek; Parakh, Neeraj; Gade, Sandeep; Trehan, Vijay

    2015-04-01

    Treatment for superior vena cava syndrome (SVCS) by percutaneous interventions has become established as a definitive therapy. However, there is a significant risk of rupture during SVC intervention. We describe an uncommon case that developed SVC rupture during percutaneous intervention for idiopathic SVCS. This was managed successfully with pericardiocentesis and rapid implantation of covered stent in SVC by rapid guiding catheter swapping technique. This, however, led to inadvertent obstruction of left innominate vein which was successfully treated by kissing balloon inflation. At 18-month follow-up, he is asymptomatic with a well apposed patent stent-graft in the SVC.

  14. The off-label use of the Amplatzer muscular VSD occluder for large patent ductus arteriosus: a case report and review.

    PubMed

    Cubeddu, Roberto J; Babin, Ivan; Inglessis, Ignacio

    2014-07-01

    A percutaneous approach to the closure of patent ductus arteriosus (PDA) is the preferred procedure in the majority of cases. However, there is little experience with percutaneous closure of unusually large PDA. We report the case of a 28-year-old female with moderate left ventricular dilation and pulmonary hypertension resulting from a large 16 mm PDA. Percutaneous closure was successfully performed using an off-label Amplatzer muscular ventricular septal defect occluder after intravascular ultrasound assessment. Technical challenges, including accurate assessment of defect size and device selection are exemplified along with a comprehensive overview of the available literature.

  15. Treatment of central venous in-stent restenosis with repeat stent deployment in hemodialysis patients.

    PubMed

    Ronald, James; Davis, Bradley; Guevara, Carlos J; Pabon-Ramos, Waleska M; Smith, Tony P; Kim, Charles Y

    2017-05-15

    To report patency rates for stent deployment for treatment of in-stent stenosis of the central veins of the chest in hemodialysis patients. A retrospective analysis was performed on 29 patients who underwent 35 secondary percutaneous transluminal stent (PTS) deployments for in-stent stenosis within the central veins that were refractory to angioplasty and ipsilateral to a functioning hemodialysis access (in-stent PTS group). For comparison, patency data were acquired for 47 patients who underwent 78 successful percutaneous transluminal angioplasty (PTA) procedures for in-stent stenosis (in-stent PTA group) and 55 patients who underwent 55 stent deployments within native central vein stenosis refractory to angioplasty (native vein PTS group). The 3-, 6-, and 12-month primary lesion patency for the in-stent PTS group was 73%, 57%, and 32%, respectively. The 3-, 6-, and 12-month primary patency for the in-stent PTA group was 70%, 38%, and 17% and for the native vein PTS group was 78%, 57%, and 26%, which were similar to the in-stent PTS group (p = 0.20 and 0.41, respectively). The 3-, 6-, and 12-month secondary access patency was 91%, 73%, and 65% for the in-stent PTS group. Sub-analysis of the in-stent PTS group revealed no difference in primary (p = 0.93) or secondary patency rates (p = 0.27) of bare metal stents (n = 23) compared with stent grafts (n = 12). Stent deployment for central vein in-stent stenosis refractory to angioplasty was associated with reasonable patency rates, which were similar to in-stent PTA and native vein PTS.

  16. Percutaneous Transcholecystic Biliary Interventions Using Gallbladder Anchors: Feasibility Study in the Swine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lopera, Jorge E., E-mail: jloper@lsuhsc.edu; Kirsch, David; Qian Zhong

    2005-05-15

    The purpose of this study was to report our initial experience with a swine model for biliary interventions by using a percutaneous transcholecystic access after suture anchor of the gallbladder. Telepaque tablets were given to five pigs to opacify the gallbladder. Under fluoroscopy, the opacified gallbladder was punctured percutaneously and three suture anchors were used to fix the anterior wall of the gallbladder to the abdominal wall. Two weeks later, the gallbladder was punctured and access into the distal common bile was obtained through the cystic duct. Balloon expandable stents were deployed into the distal common bile duct. Follow-up cholangiogramsmore » were obtained at 1 and 2 weeks. Necropsy was performed after 2 weeks to evaluate the relationship between the gallbladder and abdominal wall. Suture anchor placement was successful in all five pigs. One pig with a deep and highly positioned gallbladder developed fever, anorexia, and vomiting secondary to excessive stretch of the gallbladder. Placement of the guidewire through the extremely tortuous and small cystic ducts proved to be the most challenging step of the procedure. Metallic stents were successfully deployed in all four pigs in which it was attempted. Four animals tolerated the procedures without changes in their clinical conditions and no symptoms. Successful follow-up cholangiograms were performed at 1 and 2 weeks post-stent deployment without complications. All stents remained patent during the follow-up period. Necropsy demonstrated close attachment and adherence of the gallbladders to the antero-lateral abdominal wall in all four animals. Suture anchoring of the gallbladder is feasible in most pigs with superficially located gallbladders. This technique allows a safe and repeat access into the biliary system using a transcholecystic approach.« less

  17. Short-Term Safety and Efficacy of Femoral Vascular Closure after Percutaneous Coronary Intervention with Combination of the Boomerang(TM) Device and Intravenous Protamine Sulfate.

    PubMed

    Chen, Ching-Pei; Huang, Huang-Kai; Hsia, Chien-Hsun; Chang, Yung-Ming; Lin, Lee-Shin; Lee, Cheng-Liang

    2013-11-01

    The Cardiva Boomerang(TM) is a device used to perform femoral vascular closure. It facilitates passive hemostasis at the arteriotomy site, leaving no residual foreign body. We performed a controlled, randomized study of 60 patients undergoing percutaneous coronary intervention. Patients were randomized into two groups (30 per group) to undergo vascular closure with the Boomerang(TM) or the Perclose(TM) suture-based device after the intravenous administration of protamine sulfate. We compared overall success rates, patient-reported pain, length of time to achieve hemostasis and mobilization of the patient, and the frequency of complications in the two groups. Overall success rates using the Boomerang(TM) and Perclose(TM) devices were similarly high, at 93% and 97%, respectively. The Boomerang(TM) was significantly quicker to deploy than the PercloseTM, device deployment time, median (Q1-Q3), [2.00 (1.33-2.75) vs. 3.84 (2.75-4.38) mins, p < 0.001)]. The pain score was significantly lower in the Boomerang(TM) group (1.1 ± 1.7 vs. 6.4 ± 2.9, p < 0.001). The time the device remained in the artery and manual compression time were significantly longer with the Boomerang(TM) (p < 0.001), as well as the time taken to achieve hemostasis and time to ambulation. There were no major complications in either group and no significant differences between the groups in the frequency of minor complications. We conclude that when used in combination with intravenous protamine sulfate, the Boomerang(TM) device is as safe and effective as the Perclose(TM) device for femoral vascular closure, but quicker to deploy and less painful to patients. Boomerang; Percutaneous intervention; Vascular closure device.

  18. Percutaneous transcholecystic biliary interventions using gallbladder anchors: feasibility study in the swine.

    PubMed

    Lopera, Jorge E; Kirsch, David; Qian, Zhong; Ruiz, Bernardo; Brazzini, Augusto; Gonzales, Arturo; Castaneda-Zuniga, Wilfrido

    2005-01-01

    The purpose of this study was to report our initial experience with a swine model for biliary interventions by using a percutaneous transcholecystic access after suture anchor of the gallbladder. Telepaque tablets were given to five pigs to opacify the gallbladder. Under fluoroscopy, the opacified gallbladder was punctured percutaneously and three suture anchors were used to fix the anterior wall of the gallbladder to the abdominal wall. Two weeks later, the gallbladder was punctured and access into the distal common bile was obtained through the cystic duct. Balloon expandable stents were deployed into the distal common bile duct. Follow-up cholangiograms were obtained at 1 and 2 weeks. Necropsy was performed after 2 weeks to evaluate the relationship between the gallbladder and abdominal wall. Suture anchor placement was successful in all five pigs. One pig with a deep and highly positioned gallbladder developed fever, anorexia, and vomiting secondary to excessive stretch of the gallbladder. Placement of the guidewire through the extremely tortuous and small cystic ducts proved to be the most challenging step of the procedure. Metallic stents were successfully deployed in all four pigs in which it was attempted. Four animals tolerated the procedures without changes in their clinical conditions and no symptoms. Successful follow-up cholangiograms were performed at 1 and 2 weeks post-stent deployment without complications. All stents remained patent during the follow-up period. Necropsy demonstrated close attachment and adherence of the gallbladders to the antero-lateral abdominal wall in all four animals. Suture anchoring of the gallbladder is feasible in most pigs with superficially located gallbladders. This technique allows a safe and repeat access into the biliary system using a transcholecystic approach.

  19. Concurrent Left Ventricular Assist Device (LVAD) Implantation and Percutaneous Temporary RVAD Support via CardiacAssist Protek-Duo TandemHeart to Preempt Right Heart Failure.

    PubMed

    Schmack, Bastian; Weymann, Alexander; Popov, Aron-Frederik; Patil, Nikhil Prakash; Sabashnikov, Anton; Kremer, Jamila; Farag, Mina; Brcic, Andreas; Lichtenstern, Christoph; Karck, Matthias; Ruhparwar, Arjang

    2016-05-05

    Right ventricular failure (RVF) is an unfortunate complication that continues to limit outcomes following durable left ventricular assist device (LVAD) implantation. Despite several 'RVF risk scores' having been proposed, preoperative prediction of post-LVAD RVF remains a guesstimate at best. Current strategies for institution of temporary RVAD support are invasive, necessitate additional re-thoracotomy, restrict postoperative mobilization, and/or entail prolonged retention of prosthetic material in-situ. The authors propose a novel surgical strategy comprising simultaneous implantation of a permanent LVAD and percutaneous TandemHeart® plus ProtekDuo® to provide temporary RVAD support and preempt RVF in patients with impaired RV function.

  20. New-generation stents compared with coronary bypass surgery for unprotected left main disease: A word of caution.

    PubMed

    Benedetto, Umberto; Taggart, David P; Sousa-Uva, Miguel; Biondi-Zoccai, Giuseppe; Di Franco, Antonino; Ohmes, Lucas B; Rahouma, Mohamed; Kamel, Mohamed; Caputo, Massimo; Girardi, Leonard N; Angelini, Gianni D; Gaudino, Mario

    2018-05-01

    With the advent of bare metal stents and drug-eluting stents, percutaneous coronary intervention has emerged as an alternative to coronary artery bypass grafting surgery for unprotected left main disease. However, whether the evolution of stents technology has translated into better results after percutaneous coronary intervention remains unclear. We aimed to compare coronary artery bypass grafting with stents of different generations for left main disease by performing a Bayesian network meta-analysis of available randomized controlled trials. All randomized controlled trials with at least 1 arm randomized to percutaneous coronary intervention with stents or coronary artery bypass grafting for left main disease were included. Bare metal stents and drug-eluting stents of first- and second-generation were compared with coronary artery bypass grafting. Poisson methods and Bayesian framework were used to compute the head-to-head incidence rate ratio and 95% credible intervals. Primary end points were the composite of death/myocardial infarction/stroke and repeat revascularization. Nine randomized controlled trials were included in the final analysis. Six trials compared percutaneous coronary intervention with coronary artery bypass grafting (n = 4654), and 3 trials compared different types of stents (n = 1360). Follow-up ranged from 6 months to 5 years. Second-generation drug-eluting stents (incidence rate ratio, 1.3; 95% credible interval, 1.1-1.6), but not bare metal stents (incidence rate ratio, 0.63; 95% credible interval, 0.27-1.4), and first-generation drug-eluting stents (incidence rate ratio, 0.85; 95% credible interval, 0.65-1.1) were associated with a significantly increased risk of death/myocardial infarction/stroke when compared with coronary artery bypass grafting. When compared with coronary artery bypass grafting, the highest risk of repeat revascularization was observed for bare metal stents (hazard ratio, 5.1; 95% confidence interval, 2.1-14), whereas first-generation drug-eluting stents (incidence rate ratio, 1.8; 95% confidence interval, 1.4-2.4) and second-generation drug-eluting stents (incidence rate ratio, 1.8; 95% confidence interval, 1.4-2.4) were comparable. The introduction of new-generation drug-eluting stents did not translate into better outcomes for percutaneous coronary intervention when compared with coronary artery bypass grafting. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  1. Computed tomography measurement of the left atrial appendage for optimal sizing of the Watchman device.

    PubMed

    Xu, Bo; Betancor, Jorge; Sato, Kimi; Harb, Serge; Abdur Rehman, Karim; Patel, Kunal; Kumar, Arnav; Cremer, Paul C; Jaber, Wael; Rodriguez, L Leonardo; Schoenhagen, Paul; Wazni, Oussama

    Percutaneous left atrial appendage (LAA) occlusion is an emerging treatment option for patients with non-valvular atrial fibrillation who cannot tolerate oral anticoagulation. The Watchman device (Boston Scientific Corporation, Natick, MA, USA) is deployed at the ostium of the LAA, and an appropriately sized device is critical for successful occlusion. However, standardized imaging protocols for device sizing have not been established. We investigated the clinical utility of a standardized imaging protocol, with pre-procedural multi-detector cardiac computed tomography (MDCT), and intra-procedural transesophageal echocardiography (TEE), for Watchman device sizing. Patients who underwent Watchman device implantation between 2010 and 2016 at our center, and who had pre-procedural MDCT and intra-procedural TEE were included. MDCT measurements (CTmax, CTmin, CTmean), and TEE measurement (TEEmax) of the LAA ostium were determined for each case, and correlated with the final size of the Watchman device implanted. Demographic data and clinical outcomes were collected. The study included 80 patients (mean age: 75 ± 9.6 years; male: 68%; mean CHA2DS2-VASc score: 4.5 ± 1.4). CTmax of the LAA ostium correlated strongly with the final deployed Watchman device size (Spearman's rho: 0.81, p < 0.001), while TEEmax of the LAA ostium showed only moderate correlation with the final deployed Watchman device size (Spearman's rho: 0.61, p < 0.001). Implantation success rate was 100%. At a mean duration of follow-up of 197 days, there were no device-related complications (device embolization, cardiac perforation and pericardial tamponade). At follow-up, the vast majority of patients (76 patients; 95%) had either no or trivial (≤3 mm) residual peri-device leak on TEE. A standardized imaging protocol for assessment of Watchman device implantation incorporating pre-procedural MDCT and intra-procedural TEE, was associated with excellent procedural outcomes at a mean duration of follow-up of 197 days. Copyright © 2018 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  2. Platypnea-orthodeoxia syndrome in the elderly treated by percutaneous patent foramen ovale closure: a case series and literature review.

    PubMed

    Blanche, Coralie; Noble, Stéphane; Roffi, Marco; Testuz, Ariane; Müller, Hajo; Meyer, Philippe; Bonvini, John M; Bonvini, Robert F

    2013-12-01

    Platypnea-orthodeoxia syndrome (POS) is a rare clinical phenomenon, associating normal oxygen saturation in a supine position and arterial hypoxemia in an upright position. This pathology can be secondary to an intracardiac shunt, a pulmonary vascular shunt or a ventilation-perfusion mismatch. Cardiac POS occurs in the presence of a right-to-left cardiac shunt, most commonly through a patent foramen ovale (PFO). From our single-center prospective database of percutaneous PFO closure we identified five patients (4 females, mean age: 77 ± 11 years) out of 224 (2.2%) patients with a PFO who presented with a POS of cardiac origin. Transthoracic and transoesophageal echocardiographic examinations revealed the underlying mechanisms of POS and the diagnosis was confirmed by right-and-left cardiac catheterization (RLC) and by measuring serial blood oxygen saturation in the pulmonary veins and left atrium in supine and upright positions. PFO was associated with atrial septal aneurysm and a persistent prominent Eustachian valve in 3 patients. All patients underwent a successful percutaneous PFO closure without any immediate or subsequent complications (mean follow-up of 24 ± 18 months). Immediately after the procedure, mean arterial oxygen saturation improved from 83% ± 3 to 93% ± 2 in an upright position and symptoms disappeared. POS is a rare and under-diagnosed pathology that must be actively investigated in the presence of position-dependent hypoxemia. The diagnostic work-up must exclude other causes of hypoxemia and confirm the intracardiac shunt using either contrast echocardiography or RLC. For cardiac POS, percutaneous PFO closure is a safe and effective technique that immediately relieves orthodeoxia and patient symptoms. © 2013.

  3. [The value of SYNTAX score in predicting outcome patients undergoing percutaneous coronary intervention].

    PubMed

    Gao, Yue-chun; Yu, Xian-peng; He, Ji-qiang; Chen, Fang

    2012-01-01

    To assess the value of SYNTAX score to predict major adverse cardiac and cerebrovascular events (MACCE) among patients with three-vessel or left-main coronary artery disease undergoing percutaneous coronary intervention. 190 patients with three-vessel or left-main coronary artery disease undergoing percutaneous coronary intervention (PCI) with Cypher select drug-eluting stent were enrolled. SYNTAX score and clinical SYNTAX score were retrospectively calculated. Our clinical Endpoint focused on MACCE, a composite of death, nonfatal myocardial infarction (MI), stroke and repeat revascularization. The value of SYNTAX score and clinical SYNTAX score to predict MACCE were studied respectively. 29 patients were observed to suffer from MACCE, accounting 18.5% of the overall 190 patients. MACCE rates of low (≤ 20.5), intermediate (21.0 - 31.0), and high (≥ 31.5) tertiles according to SYNTAX score were 9.1%, 16.2% and 30.9% respectively. Both univariate and multivariate analysis showed that SYNTAX score was the independent predictor of MACCE. MACCE rates of low (≤ 19.5), intermediate (19.6 - 29.1), and high (≥ 29.2) tertiles according to clinical SYNTAX score were 14.9%, 9.8% and 30.6% respectively. Both univariate and multivariate analysis showed that clinical SYNTAX score was the independent predictor of MACCE. ROC analysis showed both SYNTAX score (AUC = 0.667, P = 0.004) and clinical SYNTAX score (AUC = 0.636, P = 0.020) had predictive value of MACCE. Clinical SYNTAX score failed to show better predictive ability than the SYNTAX score. Both SYNTAX score and clinical SYNTAX score could be independent risk predictors for MACCE among patients with three-vessel or left-main coronary artery disease undergoing percutaneous coronary intervention. Clinical SYNTAX score failed to show better predictive ability than the SYNTAX score in this group of patients.

  4. Successful percutaneous stenting of a right gastroepiploic coronary bypass graft using monorail delivery system: a case report.

    PubMed

    Alam, M; Safi, A M; Mandawat, M K; Anderson, J E; Kwan, T; Feit, A; Clark, L T

    2000-02-01

    The right gastroepiploic artery (RGEA) is being successfully used as an arterial conduit in a selected group of patients undergoing coronary artery bypass graft surgery. However, myocardial ischemia may result due to spasm, occlusion, and stenosis of this graft. The anastamosis site at distal right coronary artery (RCA) or posterior descending artery (PDA) is the most common location for stenosis of an in situ gastroepiploic coronary bypass graft. Balloon angioplasty of such stenoses has been reported with optimal short-term results. Stent deployment would decrease the restenosis rate, so that repeat procedures could be minimized for these technically challenging lesions. We describe a case of successful deployment of a stent with monorail delivery system at the anastamotic site stenosis of an in situ gastroepiploic right coronary artery bypass graft. This percutaneous coronary intervention could prevent redo coronary artery bypass graft surgery. Cathet. Cardiovasc. Intervent. 49:197-199, 2000. Copyright 2000 Wiley-Liss, Inc.

  5. Differential Event Rates and Independent Predictors of Long-Term Major Cardiovascular Events and Death in 5795 Patients With Unprotected Left Main Coronary Artery Disease Treated With Stents, Bypass Surgery, or Medication: Insights From a Large International Multicenter Registry.

    PubMed

    Kang, Se Hun; Ahn, Jung-Min; Lee, Cheol Hyun; Lee, Pil Hyung; Kang, Soo-Jin; Lee, Seung-Whan; Kim, Young-Hak; Lee, Cheol Whan; Park, Seong-Wook; Park, Duk-Woo; Park, Seung-Jung

    2017-07-01

    Identifying predictive factors for major cardiovascular events and death in patients with unprotected left main coronary artery disease is of great clinical value for risk stratification and possible guidance for tailored preventive strategies. The Interventional Research Incorporation Society-Left MAIN Revascularization registry included 5795 patients with unprotected left main coronary artery disease (percutaneous coronary intervention, n=2850; coronary-artery bypass grafting, n=2337; medication alone, n=608). We analyzed the incidence and independent predictors of major adverse cardiac and cerebrovascular events (MACCE; a composite of death, MI, stroke, or repeat revascularization) and all-cause mortality in each treatment stratum. During follow-up (median, 4.3 years), the rates of MACCE and death were substantially higher in the medical group than in the percutaneous coronary intervention and coronary-artery bypass grafting groups ( P <0.001). In the percutaneous coronary intervention group, the 3 strongest predictors for MACCE were chronic renal failure, old age (≥65 years), and previous heart failure; those for all-cause mortality were chronic renal failure, old age, and low ejection fraction. In the coronary-artery bypass grafting group, old age, chronic renal failure, and low ejection fraction were the 3 strongest predictors of MACCE and death. In the medication group, old age, low ejection fraction, and diabetes mellitus were the 3 strongest predictors of MACCE and death. Among patients with unprotected left main coronary artery disease, the key clinical predictors for MACCE and death were generally similar regardless of index treatment. This study provides effect estimates for clinically relevant predictors of long-term clinical outcomes in real-world left main coronary artery patients, providing possible guidance for tailored preventive strategies. URL: https://clinicaltrials.gov. Unique identifier: NCT01341327. © 2017 American Heart Association, Inc.

  6. [New technology for prevention of embolic events in atrial fibrillation: a systematic review on percutaneous endovascular left atrial appendage closure].

    PubMed

    Danna, Paolo; Sagone, Antonio; Proietti, Riccardo; Arensi, Andrea; Viecca, Maurizio; Santangeli, Pasquale; Di Biase, Luigi; Natale, Andrea

    2012-09-01

    Atrial fibrillation (AF) is the most common cardiac arrhythmia. The mortality rate of patients with AF is doubled as compared to non-fibrillating controls. The most relevant complication of AF is a major increase in the risk of stroke. The gold standard in reducing cerebrovascular events in AF is warfarin therapy, which is not free from contraindications and limitations. The left atrial appendage (LAA) is the main source of emboli causing stroke in AF. LAA closure is a seducing approach to stroke risk reduction in AF without anticoagulation. Since 1949, heart surgeons have performed LAA closure or amputation in patients with AF. Percutaneous endovascular LAA closure is a new, less invasive, technique to reach the goal. Several devices have been used to perform this intervention, and the results of published trials are encouraging in terms of effectiveness and relative safety of this attractive technique. In this review we examine the published trials and data on percutaneous LAA closure, with particular attention to the risks and benefits of this procedure.

  7. Minimally invasive percutaneous endovascular therapies in the management of complications of non-alcoholic fatty liver disease (NAFLD): A case report.

    PubMed

    Salsamendi, Jason; Pereira, Keith; Kang, Kyungmin; Fan, Ji

    2015-09-01

    Nonalcoholic fatty liver disease (NAFLD) represents a spectrum of disorders from simple steatosis to inflammation leading to fibrosis, cirrhosis, and even hepatocellular carcinoma. With the progressive epidemics of obesity and diabetes, major risk factors in the development and pathogenesis of NAFLD, the prevalence of NAFLD and its associated complications including liver failure and hepatocellular carcinoma is expected to increase by 2030 with an enormous health and economic impact. We present a patient who developed Hepatocellular carcinoma (HCC) from nonalcoholic steatohepatitis (NASH) cirrhosis. Due to morbid obesity, she was not an optimal transplant candidate and was not initially listed. After attempts for lifestyle modifications failed to lead to weight reduction, a transarterial embolization of the left gastric artery was performed. This is the sixth such procedure in humans in literature. Subsequently she had a meaningful drop in BMI from 42 to 36 over the following 6 months ultimately leading to her being listed for transplant. During this time, the left hepatic HCC was treated with chemoembolization without evidence of recurrence. In this article, we wish to highlight the use of minimally invasive percutaneous endovascular therapies such as transarterial chemoembolization (TACE) in the comprehensive management of the NAFLD spectrum and percutaneous transarterial embolization of the left gastric artery (LGA), a novel method, for the management of obesity.

  8. PMMA embolization to the left dorsal foot artery during percutaneous vertebroplasty for spinal metastases.

    PubMed

    Iliopoulos, Panagiotis; Panagiotis, Iliopoulos; Korovessis, Panagiotis; Panagiotis, Korovessis; Vitsas, Vasilios; Vasilios, Vitsas

    2014-05-01

    Distal arterial embolization to the foot with PMMA during vertebral augmentation has not been previously reported. We report a rare case of distal PMMA embolization to the dorsal foot artery during ipsilateral percutaneous lumbar vertebral augmentation in a patient with spinal osteolytic metastases. A 68-year-old woman was admitted because of severe disabling low back pain. Plain roentgenograms, MRI and CT-scan revealed osteolysis in the L4 and L5 vertebral bodies with prevertebral soft tissue involvement. Percutaneous vertebroplasty with PMMA was performed in L2 to L5 vertebrae under general anesthesia. Intraoperatively, leakage into the segmental vessels L3 and L5 was observed. Four hours after the procedure the clinical diagnosis of acute ischemia and drop foot on the left was made. CT-angiography justified linear cement leakage in the course of the left third lumbar vein and fifth lumbar artery, and to the ipsilateral common iliac artery. The patient was treated with low molecular heparin and the ischemia resolved without further sequelae 1 week postoperatively. PMMA leakage is a complication associated with vertebroplasty and kyphoplasty. Although the outcome of the PMMA embolization to the vessels resolved without sequelae, in our case spine surgeons and interventional radiologists should be aware on this rare complication in patients with osteolytic vertebral metastases even when contemporary cement containment techniques are used.

  9. Minimally invasive percutaneous endovascular therapies in the management of complications of non-alcoholic fatty liver disease (NAFLD): A case report

    PubMed Central

    Salsamendi, Jason; Pereira, Keith; Kang, Kyungmin; Fan, Ji

    2015-01-01

    Nonalcoholic fatty liver disease (NAFLD) represents a spectrum of disorders from simple steatosis to inflammation leading to fibrosis, cirrhosis, and even hepatocellular carcinoma. With the progressive epidemics of obesity and diabetes, major risk factors in the development and pathogenesis of NAFLD, the prevalence of NAFLD and its associated complications including liver failure and hepatocellular carcinoma is expected to increase by 2030 with an enormous health and economic impact. We present a patient who developed Hepatocellular carcinoma (HCC) from nonalcoholic steatohepatitis (NASH) cirrhosis. Due to morbid obesity, she was not an optimal transplant candidate and was not initially listed. After attempts for lifestyle modifications failed to lead to weight reduction, a transarterial embolization of the left gastric artery was performed. This is the sixth such procedure in humans in literature. Subsequently she had a meaningful drop in BMI from 42 to 36 over the following 6 months ultimately leading to her being listed for transplant. During this time, the left hepatic HCC was treated with chemoembolization without evidence of recurrence. In this article, we wish to highlight the use of minimally invasive percutaneous endovascular therapies such as transarterial chemoembolization (TACE) in the comprehensive management of the NAFLD spectrum and percutaneous transarterial embolization of the left gastric artery (LGA), a novel method, for the management of obesity. PMID:26629307

  10. Text Message Intervention to Improve Cardiac Rehab Participation

    ClinicalTrials.gov

    2017-11-14

    Myocardial Infarction; Percutaneous Coronary Intervention; Coronary Artery Bypass Surgery; Heart Valve Repair or Replacement; Heart Transplant; Left Ventricular Assist Device; Chronic Stable Angina; Chronic Stable Heart Failure

  11. Needle tract implantation of hepatoblastoma after percutaneous needle biopsy: report of a case.

    PubMed

    Sumiyoshi, Tatsuaki; Shima, Yasuo; Nishiuchi, Ritsuo; Sasaki, Kiyoshi; Kouzuki, Akihito; Noda, Yoshihiro; Hata, Yasuhiro; Uka, Kiminobu

    2014-06-01

    A 13-year-old boy was referred to us for investigation of a giant liver mass, approximately 16 cm in diameter. Sonographically guided percutaneous needle biopsy was performed and histological examination revealed a fetal-type hepatoblastoma. After four courses of chemotherapy, we performed a left hepatic trisegmentectomy. Follow-up computed tomography, 55 months after the surgery, showed a 1-cm tumor on the route of the preoperative needle biopsy. A second laparotomy revealed a peritonealised tumor, which was excised. The histology of this tumor was identical to that of the primary hepatoblastoma. To our knowledge, this is only the second report of needle tract implantation of hepatoblastoma after percutaneous needle biopsy.

  12. Is the epicardial left ventricular lead implantation an alternative approach to percutaneous attempt in patients with Steinert disease? A case report

    PubMed Central

    PAPA, ANDREA ANTONIO; RAGO, ANNA; PETILLO, ROBERTA; D’AMBROSIO, PAOLA; SCUTIFERO, MARIANNA; FEO, MARISA DE; MAIELLO, CIRO; PALLADINO, ALBERTO

    2017-01-01

    Steinert’s disease or Myotonic Dystrophy type 1 (DM1) is an autosomal dominant multisystemic disorder characterized by myotonia, muscle and facial weakness, cataracts, cognitive, endocrine and gastrointestinal involvement, and cardiac conduction abnormalities. Although mild myocardial dysfunction may be detected in this syndrome with age, overt myocardial dysfunction with heart failure is not frequent. Cardiac resynchronization therapy is an effective treatment to improve morbidity and reduce mortality in patients with DM1 showing intra-ventricular conduction delay and/or congestive heart failure. We report the case of a patient with Steinert disease showing an early onset ventricular dysfunction due to chronic right ventricular apical pacing, in which an epicardial left ventricular lead implantation was performed following the failure of the percutaneous attempt. As no relief in symptoms of heart failure, nor an improvement of left ventricular ejection fraction and reverse remodelling was observed six months later, the patient was addressed to the heart transplantation.

  13. Sub-Trochanteric Hip Fracture Following Core Decompression for Osteonecrosis in a Patient with a Pre-Existing Contralateral Occult Femoral Neck Fracture.

    PubMed

    Berger, Ryan J; Sultan, Assem A; Cole, Connor; Sodhi, Nipun; Khlopas, Anton; Mont, Michael A

    2018-06-01

    We present a unique case of a 62-year-old patient with bilateral osteonecrosis of the femoral heads secondary to corticosteroid use. She presented with an occult right femoral neck fracture and was treated with percutaneous pinning of the right femoral neck and a left-sided percutaneous drilling. Despite apparent appropriate technique, the patient sustained a left sub-trochanteric hip fracture while shifting in bed in the postoperative care unit and was taken back for cephalo-medullary nail fixation. Femoral head osteonecrosis may be an under-reported risk factor for development of pathological neck fractures. We present an overview of this topic along with suggestions for joint preservation treatment of similar patients at higher risk for perioperative fracture.

  14. Extreme premature with persistent left superior vena cava.

    PubMed

    Aboitiz-Rivera, Carlos Manuel; Blachman-Braun, Ruben; Parra-Pérez, Mariana Yazmin

    2017-10-01

    Persistent left superior vena cava (PLSVC) is a congenital anomaly, that results when there is an absence of the normal regression of the left common precardinal vein during embryogenesis. Usually, this anomaly remains asymptomatic, however, when the PLSVC drains into the left atrium this could lead to a right-to-left shunt. Additionally, this can result in inadvertent delivery of air or thrombus into the systemic circulation with potential neurologic, cardiac and renal complications. In this article, we present a case of an extreme premature Mexican newborn in which the diagnosis was made after placement of a percutaneous central venues catheter.

  15. 75 FR 54493 - Cardiovascular Devices; Reclassification of Certain Percutaneous Transluminal Coronary...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-08

    ... catheters when used for treatment of acute myocardial infarction (MI), treatment of in-stent restenosis (ISR) and/or post-deployment stent expansion. III. Device Description FDA identifies this generic type of... for the treatment of acute myocardial infarction; treatment of in-stent restenosis (ISR) and/or post...

  16. Double Guiding Catheters for Complex Percutaneous Coronary Intervention

    PubMed Central

    Chou, Shing-Hsien; Lin, Chia-Pin; Lin, Yen-Chen; Kuo, Chi-Tai; Lin, Ming-Shyan; Chang, Chi-Jen

    2012-01-01

    A large-lumen guiding catheter is often used for complex percutaneous coronary intervention—particularly when a final kissing-balloon or 2-stent technique is required. However, catheter insertion is sometimes restricted by diseased vascular access sites or a tortuous vascular route. We report 2 cases in which a unique double guiding catheter technique was used to create a lumen of sufficient size for complex percutaneous coronary intervention. In each patient, two 6F guiding catheters were used concurrently to engage the ostium of 1 target vessel. In 1 patient, these catheters were used for the delivery of 2 balloons to complete kissing-balloon dilation after single-stent placement. In the other patient, the catheters were used to deliver 2 stents sequentially to their respective target lesions. The stents were then deployed simultaneously as kissing stents, followed by high-pressure kissing-balloon postdilation. PMID:22412243

  17. Association between peak neutrophil count, clopidogrel loading dose, and left ventricular systolic function in patients with primary percutaneous coronary intervention.

    PubMed

    Wang, Xinyu; Yu, Haiyi; Li, Zhaoping; Li, Liuning; Zhang, Youyi; Gao, Wei

    2014-01-01

    Inflammation plays an important role in plaque development and left ventricular remodeling during acute myocardial infarction (AMI). Clopidogrel may exhibit some anti-inflammatory properties and high loading dose of clopidogrel results in improved clinical outcomes in patients with AMI. 357 patients who received successful primary percutaneous coronary intervention from January 2008 to March 2011 in Peking University Third Hospital were included in this study. Different loading dose of clopidogrel (300 mg, 450 mg, or 600 mg) was given at the discretion of the clinician. Neutrophils reached their peak values on the first day after AMI. Higher levels of peak neutrophil and lower left ventricular ejection fraction (LVEF) were found in patients of low clopidogrel loading dose group (300 mg or 450 mg). After adjusting for the related confounders, a logistic regression model showed that low clopidogrel loading dose remained an independent predictor of low LVEF (LVEF ≤ 50%) [OR: 1.97, 95% CI: 1.03-3.79, P = 0.04]. Low clopidogrel loading dose was associated with higher peak neutrophil count and poor left ventricular systolic function, suggesting an important role of clopidogrel loading dose in the improvement of left ventricular function and high loading dose may exhibit better anti-inflammatory properties.

  18. Percutaneous Embolization of Congenital Portosystemic Venous Fistula in an Infant with Down Syndrome

    PubMed Central

    Tanya Chun, Pattaraporn; Files, Matthew; Vo, Nghia; McAdams, Ryan M.

    2013-01-01

    Congenital intrahepatic portosystemic venous shunts are rare vascular malformations often associated with severe complications. We describe a term male infant with Down syndrome with high output heart failure secondary to a congenital arterial to portal venous fistula that was diagnosed by Doppler ultrasound. Percutaneous embolizations of the left hepatic vein, portal vein, and communicating fistulas were performed without complications, resulting in clinical improvement. A subsequent hepatic ultrasound demonstrated resolution of the pathologic fistulous communication and shunting effects. PMID:24171135

  19. Direct Percutaneous Left Ventricular Access and Port Closure

    PubMed Central

    Barbash, Israel M.; Saikus, Christina E.; Faranesh, Anthony Z.; Ratnayaka, Kanishka; Kocaturk, Ozgur; Chen, Marcus Y.; Bell, Jamie A.; Virmani, Renu; Schenke, William H.; Hansen, Michael S.; Slack, Michael C.; Lederman, Robert J.

    2012-01-01

    Objectives This study sought to evaluate feasibility of nonsurgical transthoracic catheter-based left ventricular (LV) access and closure. Background Implanting large devices, such as mitral or aortic valve prostheses, into the heart requires surgical exposure and repair. Reliable percutaneous direct transthoracic LV access and closure would allow new nonsurgical therapeutic procedures. Methods Percutaneous direct LV access was performed in 19 swine using real-time magnetic resonance imaging (MRI) and an “active” MRI needle antenna to deliver an 18-F introducer sheath. The LV access ports were closed percutaneously using a commercial ventricular septal defect occluder and an “active” MRI delivery cable for enhanced visibility. We used “permissive pericardial tamponade” (temporary fluid instillation to separate the 2 pericardial layers) to avoid pericardial entrapment by the epicardial disk. Techniques were developed in 8 animals, and 11 more were followed up to 3 months by MRI and histopathology. Results Imaging guidance allowed 18-F sheath access and closure with appropriate positioning of the occluder inside the transmyocardial tunnel. Of the survival cohort, immediate hemostasis was achieved in 8 of 11 patients. Failure modes included pericardial entrapment by the epicardial occluder disk (n = 2) and a true-apex entry site that prevented hemostatic apposition of the endocardial disk (n = 1). Reactive pericardial effusion (192 ± 118 ml) accumulated 5 ± 1 days after the procedure, requiring 1-time drainage. At 3 months, LV function was preserved, and the device was endothelialized. Conclusions Direct percutaneous LV access and closure is feasible using real-time MRI. A commercial occluder achieved hemostasis without evident deleterious effects on the LV. Having established the concept, further clinical development of this approach appears realistic. PMID:22192372

  20. Percutaneous device closure of atrial septal defect results in very early and sustained changes of right and left heart function.

    PubMed

    Monfredi, Oliver; Luckie, Matthew; Mirjafari, Hoda; Willard, Terence; Buckley, Helen; Griffiths, Linda; Clarke, Bernard; Mahadevan, Vaikom S

    2013-08-20

    To investigate the echocardiographic effects of percutaneous closure of secundum atrial septal defect (ASD) in adults and assess which pre-closure parameters predict good response to closure. ASD is a common congenital heart disease often undiscovered until adulthood. ASD closure has been revolutionized by the use of percutaneous devices. The effects of these procedures on echocardiographic parameters are not well characterized. Patients undergoing percutaneous device closure of ASD between June 2007 and June 2009 had 3 sequential echocardiograms reviewed: pre-procedure, immediate post-procedure (24 hours) and 6-8 weeks post-procedure. Significant changes from baseline were investigated using paired t-test/1-way ANOVA. Pearson correlation (2-tailed) tests were used to categorize patients as 'good responders' to closure in terms of selected parameters. 129 echocardiograms in 43 consecutive patients were included. Remodeling of both ventricles occurred immediately following ASD closure and was sustained. Right ventricular (RV) diameter in diastole decreased by 13.5% and 19.3% compared to baseline at 24 hours and 6-8 weeks post-closure, respectively (p<0.05); Left ventricular (LV) diameter in diastole increased by 8.5% and 15.6%, respectively (p<0.05). Functional parameters of the RV also demonstrated early and sustained decreases (TAPSE decreased by 8.3% and 17% compared to baseline at 24 hours and 6-8 weeks post-closure, respectively (p<0.05)). Smaller RV baseline diameter appeared to predict good response to closure. Percutaneous ASD closure has immediate, sustained benefits on multiple echocardiographic parameters. Good responders have smaller RV at baseline, suggesting early closure is preferable. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  1. Transcatheter closure of the left atrial appendage: initial experience with the WATCHMAN device

    PubMed Central

    Ding, Jiandong; Zhu, Jian; Lu, Jing; Ding, Xiuxia; Zhang, Xiaoli; Lu, Wenbin; Ao, Mingqiang; Ma, Genshan

    2015-01-01

    Background: Atrial fibrillation (AF) is the most commonly encountered clinical arrhythmia, accounting for approximately one third of hospitalizations for cardiac rhythm disturbance. In patients with non-valvular AF, approximately 90% of thrombi are thought to arise from the left atrial appendage (LAA). Anticoagulation with warfarin has been the mainstay of therapy to reduce stroke risk in these patients; however, it is not without its complications including bleeding and drug interactions. Percutaneous left atrial appendage closure can be an alternative to warfarin treatment in patients with AF at high risk for thromboembolic events and/or bleeding complications. Methods: Patients with atrial fibrillation and CHADSVASc score ≥ 2, not eligible for anticoagulation, were submitted to left atrial appendage closure using the WATCHMAN device. The procedure was performed under general anaesthesia, and was guided by fluoroscopy and transoesophageal echocardiography. Results: Percutaneous LAA closure with the WATCHMAN device was performed in all patients. At 45-day follow-up no recurrent major adverse events and especially no thromboembolic events occurred. Conclusions: Transcatheter closure of the LAA with the WATCHMAN device is generally safe and feasible. Long-term follow-up will further reveal the risk and benefits of this therapy. PMID:26629008

  2. ASD Closure in Structural Heart Disease.

    PubMed

    Wiktor, Dominik M; Carroll, John D

    2018-04-17

    While the safety and efficacy of percutaneous ASD closure has been established, new data have recently emerged regarding the negative impact of residual iatrogenic ASD (iASD) following left heart structural interventions. Additionally, new devices with potential advantages have recently been studied. We will review here the potential indications for closure of iASD along with new generation closure devices and potential late complications requiring long-term follow-up. With the expansion of left-heart structural interventions and large-bore transseptal access, there has been growing experience gained with management of residual iASD. Some recently published reports have implicated residual iASD after these procedures as a potential source of diminished clinical outcomes and mortality. Additionally, recent trials investigating new generation closure devices as well as expanding knowledge regarding late complications of percutaneous ASD closure have been published. While percutaneous ASD closure is no longer a novel approach to managing septal defects, there are several contemporary issues related to residual iASD following large-bore transseptal access and new generation devices which serve as an impetus for this review. Ongoing attention to potential late complications and decreasing their incidence with ongoing study is clearly needed.

  3. Left Atrial Appendage Eccentricity and Irregularity Are Associated With Residual Leaks After Percutaneous Closure.

    PubMed

    Rajwani, Adil; Shirazi, Masoumeh G; Disney, Patrick J S; Wong, Dennis T L; Teo, Karen S L; Delacroix, Sinny; Chokka, Ramesh G; Young, Glenn D; Worthley, Stephen G

    2015-12-01

    Predictors of residual leak following percutaneous LAA closure were evaluated. Left atrial appendage (LAA) closure aims to exclude this structure from the circulation, typically using a circular occluder. A noncircular orifice is frequently encountered however, and fibrous remodeling of the LAA in atrial fibrillation may restrict orifice deformation. Noncircularity may thus be implicated in the occurrence of residual leak despite an appropriately oversized device. Pre-procedural multislice computerized tomography was used to quantify LAA orifice eccentricity and irregularity. Univariate predictors of residual leak were identified with respect to the orifice, device, and relevant clinical variables, with the nature of any correlations then further evaluated. Eccentricity and irregularity indexes of the orifice in 31 individuals were correlated with residual leak even where the device was appropriately oversized. An eccentricity index of 0.15 predicted a residual leak with 85% sensitivity and 59% specificity. An irregularity index of 0.05 predicted a significant residual leak ≥3 mm with 100% sensitivity and 86% specificity. Orifice size, device size, degree of device oversize, left atrial volume, and pulmonary artery pressure were not predictors of residual leak. Eccentricity and irregularity of the LAA orifice are implicated in residual leak after percutaneous closure even where there is appropriate device over-size. Irregularity index in particular is a novel predictor of residual leak, supporting a closer consideration of orifice morphology before closure. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  4. Imaging Techniques in Percutaneous Cardiac Structural Interventions: Atrial Septal Defect Closure and Left Atrial Appendage Occlusion.

    PubMed

    Rodríguez Fernández, Antonio; Bethencourt González, Armando

    2016-08-01

    Because of advances in cardiac structural interventional procedures, imaging techniques are playing an increasingly important role. Imaging studies show sufficient anatomic detail of the heart structure to achieve an excellent outcome in interventional procedures. Up to 98% of atrial septal defects at the ostium secundum can be closed successfully with a percutaneous procedure. Candidates for this type of procedure can be identified through a systematic assessment of atrial septum anatomy, locating and measuring the size and shape of all defects, their rims, and the degree and direction of shunting. Three dimensional echocardiography has significantly improved anatomic assessments and the end result itself. In the future, when combined with other imaging techniques such as cardiac computed tomography and fluoroscopy, 3-dimensional echocardiography will be particularly useful for procedure guidance. Percutaneous closure of the left atrial appendage offers an alternative for treating patients with atrial fibrillation and contraindication for oral anticoagulants. In the future, the clinical focus may well turn to stroke prevention in selected patients. Percutaneous closure is effective and safe; device implantation is successful in 94% to 99% of procedures. However, the procedure requires an experienced cardiac structural interventional team. At present, 3-dimensional echocardiography is the most appropriate imaging technique to assess anatomy suitability, select device type and size, guide the procedure alongside fluoroscopy, and to follow-up the patient afterwards. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  5. Percutaneous left atrial appendage occlusion for stroke prevention in patients with atrial fibrillation and contraindication for anticoagulation.

    PubMed

    Grosset-Janin, D; Barth, E; Bertrand, B; Detante, O

    2015-05-01

    Stroke, as the third cause of death in developed countries, is a public health issue. Atrial fibrillation is an important cause of ischemic stroke and its prevention is efficient with oral anticoagulation. However, oral anticoagulation can be contraindicated because of hemorrhagic risk related to these treatments. Percutaneous left atrial appendage occlusion is a new alternative of oral anticoagulation for patients with atrial fibrillation and high risk of cardio-embolic stroke but contraindicated for oral anticoagulation. We describe in this paper the procedure of left atrial appendage occlusion with the Amplatzer cardiac plug device, used in our center in Grenoble university hospital, for the first three patients who have been treated with this device. These three patients (one man and two women) have all atrial fibrillation with neurological complication of this arrhythmia, as ischemic stroke. Oral anticoagulation is indicated to prevent another ischemic stroke. However, they all have a high risk of cerebral bleeding for different reasons (cavernomatosis, history of intracerebral hemorrhage and aneurysm of the polygon of Willis). Consequently, they have a high risk of cardio-embolic complication but contraindication for oral anticoagulation. They have been treated by left atrial appendage occlusion with Amplatzer cardiac plug device by percutaneous and trans-septal access. Then, they have been followed by neurologist and cardiologist, with clinical and paraclinical evaluation by echocardiography. Our three first patients have been successfully implanted, without periprocedural complication. No latest adverse event was observed, and particularly no cardiac or neurologic adverse event. The technique of left atrial appendage occlusion is a very interesting and promising technique for ischemic stroke prevention in patient with high risk of cardio-embolic complication because of atrial fibrillation, but high risk of bleeding and contraindication for oral anticoagulation. Because of frequency of both atrial fibrillation and contraindication for oral anticoagulation, occlusion of the left atrial appendage should become an interesting alternative for many patients. However, it remains an invasive procedure and efficacy and indications need to be evaluated in further clinical trials. Risk/benefit ratio must be carefully assessed and compared to that of the new anticoagulant drugs. Copyright © 2015. Published by Elsevier Masson SAS.

  6. A repositionable valved stent for endovascular treatment of deteriorated bioprostheses.

    PubMed

    Zegdi, Rachid; Khabbaz, Ziad; Borenstein, Nicolas; Fabiani, Jean-Noël

    2006-10-03

    We report our animal experience of endovascular valve replacement (VR) of failed bioprosthesis (BP) using an original delivery catheter allowing repositioning of the valved stent (VS). Among the different devices designed for percutaneous VR, none has the potential for repositioning of a fully deployed VS. Five sheep underwent, on beating heart, tricuspid VR with a stented BP. Prolapse of 1 leaflet was induced by tearing. For the endovascular tricuspid VR, we used a VS constructed with a nitinol self-expandable stent and a porcine stentless aortic valve. We also used an original delivery catheter, allowing repositioning of the VS through a compression or relaxation mechanism of the stent. Epicardial echocardiography and right ventriculography showed severe tricuspid regurgitation, with a regurgitant jet extending to the inferior vena cava. After surgical exposure to the infrarenal inferior vena cava, the VS was successfully implanted inside the failed BP in all cases. Repositioning of the fully deployed VS was always possible. Echocardiographic and macroscopic studies revealed adequate VS positioning, excellent leaflet opening, and absence of any intraprosthetic or periprosthetic leak. Endovascular VR was easily performed in sheep with failed BP in the tricuspid position. The novel delivery catheter allowed adequate repositioning of our fully deployed VS before its definitive release. One may anticipate that the safety improvement conferred by this new technology will certainly favor the development of percutaneous VR in clinical practice.

  7. Percutaneous coronary angioplasty of a left anterior descending artery implanted on a Dacron coronary prosthesis on an aortic conduit.

    PubMed

    Drobinski, G; Thomas, D; Funck, F; Metzger, J P; Canny, M; Grosgogeat, Y

    1986-08-01

    Certain surgical techniques may make it difficult to catheterize the coronary ostia and perform percutaneous coronary angioplasty. We report the case of a 48 year old patient who developed unstable angina four years after a Bentall's procedure with reimplantation of the coronary arteries on a Dacron coronary prosthesis. The anginal pain was related to very severe stenosis of the proximal segment of the left anterior descending artery. The difficulties encountered during the dilatation procedure were due to: (a) the ectopic position of the ostium of the prosthesis on the anterior aortic wall; (b) the forces exerted on the aortic prosthesis wall and on the valvular prosthesis during positioning of the guiding catheter which were poorly tolerated and induced a vagal reaction; (c) the direction taken by the distal tip of the guiding catheter, perpendicular to the wall of the aortic prosthesis; (d) the sinuosity of the arterial trajectory: the left coronary segment of the coronary prosthesis was directed towards the left circumflex artery rather than towards the left anterior descending artery. Coronary angioplasty succeeded after relatively complex technical procedures: special guiding catheter, unusual intra-aortic manoeuvres for positioning the guiding catheter, dilatation catheter change on a 3-metre long guide wire in order to cross the stenotic segment; this was performed with a super low-profiled dilatation catheter. There were no complications and anginal pain disappeared.

  8. A case of staghorn stones in a kidney with an ileal ureter treated by percutaneous nephrolithotomy.

    PubMed

    Gao, Xiaofeng; Zhou, Tie; Li, Jinyi; Sun, Yinghao

    2008-12-01

    A 59-year-old man was admitted to hospital for investigation of a 1-year history of intermittent hematuria. He had undergone ileal ureteral replacement for left renal stones 36 years earlier. Renal ultrasonography, physical examination, abdominal plain radiography, intravenous urography, CT urography, measurement of serum levels of creatinine, urea and electrolytes, renal scintigraphy, urinalysis and urine culture. Staghorn calculi in the left kidney, with a high-lying anastomosis between the renal pelvis and the proximal ileal segment. The patient underwent percutaneous nephrolithotomy via a middle-calyx access for the large staghorn stones. After surgery, no residual calculi were found and the patient was discharged with an uneventful postoperative course. At 1 month, renal scintigraphy showed normal bilateral kidney function. The patient received potassium citrate supplementation and was followed up with 6-monthly imaging studies. At the last report, he had been stone-free for 7 months.

  9. Left Atrial Appendage Closure in Atrial Fibrillation: A World without Anticoagulation?

    PubMed Central

    Contractor, Tahmeed; Khasnis, Atul

    2011-01-01

    Atrial Fibrillation (AF) is a common arrhythmia with an incidence that is as high as 10% in the elderly population. Given the large proportion of strokes caused by AF as well as the associated morbidity and mortality, reducing stroke burden is the most important part of AF management. While warfarin significantly reduces the risk of AF-related stroke, perceived bleeding risks and compliance limit its widespread use in the high-risk AF population. The left atrial appendage is believed to be the “culprit” for thrombogenesis in nonvalvular AF and is a new therapeutic target for stroke prevention. The purpose of this review is to explore the evolving field of percutaneous LAA occlusion. After briefly highlighting the risk of stroke with AF, problems with warfarin, and the role of the LAA in clot formation, this article discusses the feasibility and efficacy of various devices which have been developed for percutaneous LAA occlusion. PMID:21559225

  10. A proof-of-concept study of the VeinScrew: A new percutaneous venous closure device.

    PubMed

    Boersma, Doeke; de Borst, Gert Jan; Moll, Frans L

    2017-02-01

    Objective This study evaluated the concept of percutaneous closure of insufficient veins using the VeinScrew principle. Methods The VeinScrew is designed to place a spring-shaped implant that contracts and clamps around the vein. The ability of the device to occlude adequately was tested in a bench model experiment. The feasibility of accurate placement and adequate venous occlusion was evaluated in an animal experiment and in a human cadaveric experiment. Results The VeinScrew implant occluded up to a pressure of 135 mmHg. In vivo studies confirmed that deployment was challenging but technically feasible, and subsequent phlebography showed closure of the vein. The cadaveric study showed that percutaneous placement of the evolved VeinScrew around the great saphenous vein was feasible and accurate. Conclusions The current studies show the feasibility of the VeinScrew concept. Future developments and translational studies are necessary to determine the potential of this technique as a new option in the phlebologist's toolbox.

  11. Effects of abdominally implanted radiotransmitters with percutaneous antennas on migration, reproduction, and survival of Canada geese

    USGS Publications Warehouse

    Hupp, Jerry W.; Pearce, John M.; Mulcahy, Daniel M.; Miller, David A.

    2006-01-01

    Abdominally implanted radiotransmitters with percutaneous antennas are increasingly used to monitor movements, survival, and reproduction of waterbirds. However, there has been relatively little assessment of the effects of such radios on avian demographic parameters or migration. We implanted either a 26- or 35-g abdominal transmitter with percutaneous antenna in 198 adult female lesser Canada geese (Branta canadensis parvipes) in Anchorage, Alaska during 2000 and 2001. We compared migration chronology, reproductive effort, and survival of radiomarked females to 118 control females marked with leg bands. Arrival dates following spring migration were similar among females in different treatments in 2001. However, in 2002, wind direction during late migration was less favorable, and arrival of females with 35-g radiotransmitters lagged 1–2 days behind that of control females. Nest initiation dates, clutch size, and mean egg volume were similar for 152 nests of females that lacked radios and 62 nests of radiomarked females. Estimated nesting propensity for females with operable radiotransmitters was 61% and 72% in 2001 and 2002, respectively. Apparent annual survival (ϕ = 0.82, 95% confidence interval: 0.76 to 0.87) was similar among treatments in the first year after geese were marked. In the second and third years after marking, model-averaged estimates for survival of females with large radiotransmitters were 10% lower than estimates for control females. However, the effect of large radios on long-term survival was equivocal because of uncertainty surrounding treatment estimates. We conclude that abdominally implanted radiotransmitters with percutaneous antennas had small effects on migration chronology but no apparent effects on fecundity. Abdominal transmitters can provide unbiased estimates of anserine survival in the first year after deployment. Because of the potentially greater effects of larger transmitters on migration and long-term survival, we recommend that biologists minimize the size of implanted transmitters and deploy radios with caution if long-term survival of marked birds is a concern.

  12. [Surgical cryoablation and left ventriculoplasty for electrical storm after acute myocardial infarction].

    PubMed

    Tobe, Satoshi; Yoshida, K; Adachi, K; Fukase, K; Tanimura, N; Yamaguchi, M

    2008-03-01

    A 65-year-old man was referred to our hospital to treat recent anterior myocardial infarction. Coronary artery angiography showed acute occlusion of left anterior descending coronary artery (LAD) and chronic occlusion of right coronary artery. After emergent percutaneous coronary intervention for LAD, drug-refractory electrical storm necessitating frequent electrical defibrillating cardioversion occurred. This patient successfully underwent surgical cryoablation, left ventriculoplasty and coronary revascularization. At 2 years and 10th month after the operation, he is well without limitation of daily activities and any evidence of myocardial ischemia and ventricular tachycardia.

  13. Percutaneous closure of patent ductus arteriosus in children: Immediate and short-term changes in left ventricular systolic and diastolic function.

    PubMed

    Gupta, Saurabh Kumar; Krishnamoorthy, Km; Tharakan, Jaganmohan A; Sivasankaran, S; Sanjay, G; Bijulal, S; Anees, T

    2011-07-01

    To evaluate the effect of percutaneous closure of patent ductus arteriosus (PDA) on left ventricular (LV) systolic and diastolic function in children. Limited studies are available on alteration in LV hemodynamics, especially diastolic function, after PDA closure. Thirty-two consecutive children with isolated PDA treated by trans-catheter closure were studied. The LV systolic and diastolic function were assessed by two-dimensional (2D) echocardiography and tissue Doppler imaging 1 day before the PDA closure, on day 1, and on follow-up. At baseline, none of the patients had LV systolic dysfunction. On day 1 post-PDA closure, 8 (25%) children developed LV systolic dysfunction. The baseline LV ejection fraction (LVEF), LV end-systolic dimension (LVESD), and PDA diastolic gradient predicted the post-closure LVEF. Patients who developed post-closure LV systolic dysfunction had poorer LV diastolic function than those who did not. LV diastolic properties improved after PDA closure; however, the improvement in LV diastolic properties lagged behind the improvement in the LV systolic function. All children were asymptomatic and had normal LVEF on follow up of >3 months. Percutaneous closure of PDA is associated with the reversible LV systolic dysfunction. Improvement in the LV diastolic function lags behind that in the LV systolic function.

  14. Rare malposition following left jugular vein catheterization: Case reports and a literature review.

    PubMed

    Wang, Lin; Liu, Zhangsuo; Wang, Changan; Liu, Dongwei; Yuan, Yiqiang

    2015-01-01

    The number of patients requiring chronic hemodialysis via a tunneled cuffed catheter is increasing. The right internal jugular vein (IJV) is generally the preferred site of percutaneous insertion. In certain situations, for example, in patients with a history of multiple access failures, catheterization of the left IJV is an important option. In this report, we present two rare cases of catheter malposition after left IJV catheterization; catheter adjustments, with the help of chest radiographs, resulted in a positive outcome in both cases. These cases exemplify the difficulties associated with left IJV catheterization, of which there are few reports in the published literature.

  15. Left-main restenosis in the DES era-a call for action.

    PubMed

    di Palma, Gaetano; Cortese, Bernardo

    2017-11-10

    Percutaneous treatment of the unprotected left main trunk (ULM), defined as a vessel without patent bypass graft either to the left circumflex (LCX) or left anterior descending (LAD) artery, has gained a precise role thanks to recent scientific evidence. Although new generation drug-eluting stents have already proven to be safer, there is still a consistent risk of restenosis and late adverse events. The optimal management of a ULM restenosis is still debated. Here we aim at presenting a review of the available data in literature and show our choice for treating it. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Successful use of a left ventricular apical access and closure device for second-generation transapical aortic valve implantation.

    PubMed

    Conradi, Lenard; Seiffert, Moritz; Shimamura, Kazuo; Schirmer, Johannes; Blankenberg, Stefan; Reichenspurner, Hermann; Diemert, Patrick; Treede, Hendrik

    2014-09-01

    Transcatheter aortic valve implantation (TAVI) has become routine for the treatment of high-risk patients with aortic stenosis. We assessed safety and feasibility of a left ventricular apical access and closure device combined with second-generation transapical (TA) TAVI transcatheter heart valves (THV). Three elderly, comorbid patients (logEuroSCORE I 13.0-31.1%) received transapical aortic valve implantation (TA-AVI) via the Apica ASC device (Apica Cardiovascular Ltd., Galway, Ireland) using second-generation THV (Medtronic Engager [Medtronic 3F Therapeutics, Santa Ana, California, United States], JenaValve [JenaValve Technology GmbH, Munich, Germany], Symetis Acurate [Symetis S.A., Ecublens, Switzerland]). Access was gained using a non-rib-spreading technique and a novel access and closure device. THV deployment was successful with excellent hemodynamic outcome (no PVL, n = 2; trace PVL, n = 1; mean transvalvular gradients, 5-19 mm Hg) and complete apical hemostasis. No periprocedural major adverse events occurred and Valve Academic Research Consortium-2-defined composite end point of device success was met in all cases. Safety and feasibility of TA-AVI using the ASC device with second-generation THV was demonstrated. Combining latest available technology is a major step toward improved functional outcome and decreased surgical trauma in TA-AVI. Potentially, technical enhancements may eventually pave the way toward a fully percutaneous TA-AVI procedure. Georg Thieme Verlag KG Stuttgart · New York.

  17. Percutaneous Endoscopic Colostomy: A New Technique for the Treatment of Recurrent Sigmoid Volvulus

    PubMed Central

    Al-Alawi, Ibrahim K.

    2010-01-01

    Sigmoid volvulus is a common cause of large bowel obstruction in western countries and Africa. It accounts for 25% of the patients admitted to the hospital for large bowel obstruction. The acute management of sigmoid volvulus is sigmoidoscopic decompression. However, the recurrence rate can be as high as 60% in some series. Recurrent sigmoid volvulus in elderly patients who are not fit for definitive surgery is difficult to manage. The percutaneous endoscopic placement of two percutaneous endoscopic colostomy tube placement is a simple and relatively safe procedure. The two tubes should be left open to act as vents for the colon from over-distending. In our opinion, this aspect is key to its success as it keeps the sigmoid colon deflated until adhesions form between the colon and the abdominal wall. PMID:20339184

  18. [Usefullness of the StoneBreaker lithotripter for percutaneous nephrolithotomy].

    PubMed

    del Peso, Almudena Coloma; González, Inmaculada Fernández; Gálvez, Milagros Jiménez; Abad, Pablo Garrido; Fajardo, Gloria Bocardo; Fernández, Luis Miguel Herranz; Arjona, Manuel Fernández; Torres, Lorenzo Herrero; Sanz, Ignacio Pereira

    2008-01-01

    Throughout the history, many devices have been used for breaking urinary tract stones. StoneBreaker (LMA Urology, Gland, Switzerland) is a second generation of intracorporeal lithotripter, pneumatic and portable, which adds several new advantages, like effectiveness in stone fragmentation and easy handling, very useful during percutaneous lithotripsy. We report the case of a 40 year-old male patient, with a left kidney pyelic lithiasis, who was treated by percutaneous lithotripsy, under general anaesthesia, with StoneBreaker (LMA Urology, Gland, Switzerland) as lithotripter. StoneBreaker (LMA Urology, Gland, Switzerland) is a lithotripter usable with rigid and semirigid ureteroscopes, much more powerful than its predecessors. It is able to decrease the number of shocks necessary for stone fragmentation, without bigger tissue reaction. It also has a more comfortable design due to the absence of connections, and its power by replaceable carbon dioxide cartridges.

  19. Relation between coronary arterial dominance and left ventricular ejection fraction after ST-segment elevation acute myocardial infarction in patients having percutaneous coronary intervention.

    PubMed

    Veltman, Caroline E; Hoogslag, Georgette E; Kharbanda, Rohit K; de Graaf, Michiel A; van Zwet, Erik W; van der Hoeven, Bas L; Delgado, Victoria; Bax, Jeroen J; Scholte, Arthur J H A

    2014-12-01

    The presence of a left dominant coronary artery system is associated with worse outcome after ST-segment elevation myocardial infarction (STEMI) compared with right dominance or a balanced coronary artery system. However, the association between coronary arterial dominance and left ventricular (LV) function at follow-up after STEMI is unclear. The present study aimed at evaluating the relation between coronary arterial dominance and LV ejection fraction (LVEF) shortly after STEMI and at 12-month follow-up. A total of 741 patients with STEMI (mean age 60 ± 11 years and 77% men) were evaluated with 2-dimentional echocardiography within 48 hours of admission (baseline) and at 12-month follow-up after STEMI. Coronary arterial dominance was assessed on the angiographic images obtained during primary percutaneous coronary intervention. A right, left, and balanced dominant coronary artery system was noted in 640 (86%), 58 (8%), and 43 (6%) patients, respectively. At baseline, significant difference in LV function was observed, with slightly lower LVEF in patients with a left dominant coronary artery system (LVEF 45 ± 8% vs 48 ± 9% and 50 ± 9%, for left dominant, right dominant, and balanced coronary artery system respectively, p = 0.03). However, at 12-month follow-up no differences in LV function or volumes were observed among the different coronary arterial dominance groups. In conclusion, patients with a left dominant coronary artery system had lower LVEF early after STEMI. At 12-month follow-up, differences in LVEF were no longer present among the different coronary arterial dominance groups. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Astronaut Story Musgrave during deployment of solar array panels on HST

    NASA Image and Video Library

    1993-12-09

    STS061-48-027 (9 Dec 1993) --- Astronaut F. Story Musgrave moves about in the Space Shuttle Endeavour's cargo bay during the deployment of the solar array panels on the Hubble Space Telescope (HST) during the final of five STS-61 space walks. The left hand of astronaut Jeffrey A. Hoffman appears at lower left corner.

  1. Comparison of one-year outcomes of percutaneous coronary intervention versus coronary artery bypass grafting in patients with unprotected left main coronary artery disease and acute coronary syndromes (from the CUSTOMIZE Registry).

    PubMed

    Caggegi, Anna; Capodanno, Davide; Capranzano, Piera; Chisari, Alberto; Ministeri, Margherita; Mangiameli, Andrea; Ronsivalle, Giuseppe; Ricca, Giovanni; Barrano, Giombattista; Monaco, Sergio; Di Salvo, Maria Elena; Tamburino, Corrado

    2011-08-01

    Uncertainty surrounds the optimal revascularization strategy for patients with left main coronary artery disease presenting with acute coronary syndromes (ACSs), and adequately sized specific comparisons of percutaneous and surgical revascularization in this scenario are lacking. The aim of this study was to evaluate the incidence of 1-year major adverse cardiac events (MACEs) in patients with left main coronary artery disease and ACS treated with percutaneous coronary intervention (PCI) and drug-eluting stent implantation or coronary artery bypass grafting (CABG). A total of 583 patients were included. At 1 year, MACEs were significantly higher in patients treated with PCI (n = 222) compared to those treated with CABG (n = 361, 14.4% vs 5.3%, p <0.001), driven by a higher rate of target lesion revascularization (8.1% vs 1.7%, p = 0.001). This finding was consistent after statistical adjustment for MACEs (adjusted hazard ratio [HR] 2.7, 95% confidence interval [CI] 1.2 to 5.9, p = 0.01) and target lesion revascularization (adjusted HR 8.0, 95% CI 2.2 to 28.7, p = 0.001). No statistically significant differences between PCI and CABG were noted for death (adjusted HR 1.1, 95% CI 0.4 to 3.0, p = 0.81) and myocardial infarction (adjusted HR 4.8, 95% CI 0.3 to 68.6, p = 0.25). No interaction between clinical presentation (ST-segment elevation myocardial infarction or unstable angina/non-ST-segment elevation myocardial infarction) and treatment (PCI or CABG) was observed (p for interaction = 0.68). In conclusion, in patients with left main coronary artery disease and ACS, PCI is associated with similar safety compared to CABG but higher risk of MACEs driven by increased risk of repeat revascularization. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. Evaluation of left ventricular function by tissue Doppler and speckle-derived strain rate echocardiography after percutaneous ductus closure.

    PubMed

    Amoogzar, Hamid; Shakiba, Ali Mohammad; Derakhshan, Dorna; Ajami, Gholamhossein; Cheriki, Sirous; Borzouee, Mohammad; Edraki, Mohammad Reza; Mehdizadegan, Nima

    2015-01-01

    The aim of this study was to evaluate the left ventricular systolic and diastolic function before and after transcatheter percutaneous patent ductus arteriosus (PDA) closure. 21 children (age >6 months old) diagnosed with hemodynamically significant PDA underwent percutaneous PDA closure. Conventional, Doppler and tissue Doppler imaging and speckled-derived strain rate echocardiography were done at pre-closure, 1 day (early) and 1 month (late) post-closure. Mean age of the patients (female/male: 1.3) was 17.54 ± 24.7 months with the mean PDA diameter of 3.6 ± 0.8 mm. Systolic measures (ejection fraction, shortening fraction) reduced significantly early after PDA closure (P < 0.05). After 1 month, both improved significantly; ultimately, after 1 month no change was observed in systolic function measures compared with the pre-closure status. Early and late diastolic flow velocities of mitral (E M and A M) reduced considerably in early and late post-closure time (P < 0.05). Both early tissue Doppler early velocity of lateral mitral annulus (E'M) and early to late velocity ratio (E'M/A'M) of lateral mitral annulus decreased significantly (P = 0.02) in early post-closure. After 1 month, E'M increased considerably. (P = 0.01) but E'M/A'M had an insignificant rise (P > 0.05). E M/E'M ratio did not change in early post-closure but it had a considerable reduction in the subsequent month compared with the pre- and early post-closure (P < 0.001 for both occasions). Global and segmental longitudinal strain measures reduced significantly early after PDA closure (P < 0.05) but it improved remarkably in the subsequent month. Transcatheter PDA closure causes a significant decrease in left ventricular performance early after PDA closure which recovers completely within 1 month. Also PDA size can affect post-closure left ventricular function.

  3. Comparison of usefulness of N-terminal pro-brain natriuretic peptide as an independent predictor of cardiac function among admission cardiac serum biomarkers in patients with anterior wall versus nonanterior wall ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention.

    PubMed

    Haeck, Joost D E; Verouden, Niels J W; Kuijt, Wichert J; Koch, Karel T; Van Straalen, Jan P; Fischer, Johan; Groenink, Maarten; Bilodeau, Luc; Tijssen, Jan G P; Krucoff, Mitchell W; De Winter, Robbert J

    2010-04-15

    The purpose of the present study was to determine the prognostic value of N-terminal pro-brain natriuretic peptide (NT-pro-BNP), among other serum biomarkers, on cardiac magnetic resonance (CMR) imaging parameters of cardiac function and infarct size in patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention. We measured NT-pro-BNP, cardiac troponin T, creatinine kinase-MB fraction, high-sensitivity C-reactive protein, and creatinine on the patients' arrival at the catheterization laboratory in 206 patients with ST-segment elevation myocardial infarction. The NT-pro-BNP levels were divided into quartiles and correlated with left ventricular function and infarct size measured by CMR imaging at 4 to 6 months. Compared to the lower quartiles, patients with nonanterior wall myocardial infarction in the highest quartile of NT-pro-BNP (> or = 260 pg/ml) more often had a greater left ventricular end-systolic volume (68 vs 39 ml/m(2), p <0.001), a lower left ventricular ejection fraction (42% vs 54%, p <0.001), a larger infarct size (9 vs 4 g/m(2), p = 0.002), and a larger number of transmural segments (11% of segments vs 3% of segments, p <0.001). Multivariate analysis revealed that a NT-pro-BNP level of > or = 260 pg/ml was the strongest independent predictor of left ventricular ejection fraction in patients with nonanterior wall myocardial infarction compared to the other serum biomarkers (beta = -5.8; p = 0.019). In conclusion, in patients with nonanterior wall myocardial infarction undergoing primary percutaneous coronary intervention, an admission NT-pro-BNP level of > or = 260 pg/ml was a strong, independent predictor of left ventricular function assessed by CMR imaging at follow-up. Our findings suggest that NT-pro-BNP, a widely available biomarker, might be helpful in the early risk stratification of patients with nonanterior wall myocardial infarction. Copyright 2010 Elsevier Inc. All rights reserved.

  4. Intraprocedural left ventricular free wall rupture diagnosed by left ventriculogram in a patient with infero-posterior myocardial infarction and severe aortic stenosis.

    PubMed

    Konishi, Takao; Funayama, Naohiro; Yamamoto, Tadashi; Nishihara, Hiroshi; Hotta, Daisuke; Kikuchi, Kenjiro; Yokoyama, Hideo; Ohori, Katsumi

    2016-06-06

    Left ventricular wall rupture remains a major lethal complication of acute myocardial infarction and hypertension is a well-known predisposing factor of cardiac rupture after myocardial infarction. An 87-year-old man was admitted to our hospital, diagnosed as acute myocardial infarction (AMI). The echocardiogram showed 0.67-cm(2) aortic valve, consistent with severe aortic stenosis (AS). A coronary angiography showed a chronic occlusion of the proximal left circumflex artery and a 99 % stenosis and thrombus in the mid right coronary artery. During percutaneous angioplasty of the latter, transient hypotension and bradycardia developed at the time of balloon inflation, and low doses of noradrenaline and etilefrine were intravenously administered as needed. The patient suddenly lost consciousness and developed electro-mechanical dissociation. Cardio-pulmonary resuscitation followed by insertion of an intra-aortic balloon pump (IABP) and percutaneous cardiopulmonary support were initiated. The echocardiogram revealed moderate pericardial effusion, though the site of free wall rupture was not distinctly visible. A left ventriculogram clearly showed an infero-posterior apical wall rupture. Surgical treatment was withheld because of the interim development of brain death. In this patient, who presented with severe AS, the administration of catecholamine to stabilize the blood pressure probably increased the intraventricular pressures considerably despite apparently normal measurements of the central aortic pressure. IABP, temporary pacemaker, or both are recommended instead of intravenous catecholamines for patients with AMI complicated with significant AS to stabilize hemodynamic function during angioplasty.

  5. Transcatheter closure of patent ductus arteriosus reverses left ventricular dysfunction in a septuagenarian.

    PubMed

    Rapacciuolo, Antonio; Losi, Maria Angela; Borgia, Francesco; De Angelis, Maria Carmen; Esposito, Francesca; Cavallaro, Massimo; De Rosa, Roberta; Piscione, Federico; Chiariello, Massimo

    2009-04-01

    A 70-year-old man was admitted because of a 6-month history of progressive dyspnoea on exertion. The medical history showed that he suffered from patent ductus arteriosus (PDA) that was closed at 35 years of age by surgical ligation. Subsequently, up to year 1992, no evidence of residual left-to-right shunt was found. When he first came to our attention, we performed an echocardiographic test evidencing left ventricular dilation and contractile dysfunction and a recurrence of PDA. To exclude other possible causes of congestive heart failure, we performed several tests, including a coronary angiogram that showed coronary atherosclerosis without significant lesions. The haemodynamic study confirmed that the PDA was associated with a mild pulmonary hypertension with a QP: QS of 2: 1. The patient did not report any cardiovascular risk factor. Therefore, we concluded that PDA was responsible for congestive heart failure in this patient. We performed percutaneous closure of PDA, which was able to reverse left ventricular dilation and dysfunction, improving the patient's symptoms, at 1 month as well as 4 months after the interventional procedure. Although this kind of device is frequently used in the paediatric population, adult patients may present different challenges in proper management, such as poor visualization, calcification and pulmonary hypertension. In the description of the case reported here, we show that a PDA can present as congestive heart failure in the elderly. Percutaneous closure can be very effective in ameliorating left ventricular performance as well as symptoms.

  6. Percutaneous transhepatic bile drainage.

    PubMed Central

    Mori, K; Misumi, A; Sugiyama, M; Okabe, M; Matsuoka, T

    1977-01-01

    Percutaneous transhepatic bile drainage was performed in 13 patients with obstructive jaundice, using a combination of the PTC technique and a Seldinger angiography catheter. In 11 cases, the outflow of bile through the catheter was satisfactory and complications were few. Since the risk of the procedure is low and it can be done without laparotomy, it is an ideal technic for biliary decompression before attempting to do a resection. Also, repeated cholangiography through a catheter which is left in place is helpful as a diagnostic aid before and after surgery. Images Fig. 3. Fig. 4. Fig. 5. Fig. 6. PMID:831630

  7. Experimental and clinical studies on transmyocardial laser revascularzation (TMLR)

    NASA Astrophysics Data System (ADS)

    Okada, Masayoshi

    2005-07-01

    The number of patients with coronary artery disease has been increasing in Japan and several kinds of treatments have been performed to reduce their cardiovascular diseases. In patients with small branches, or diffuse stenotic lesions of the coronary arteries, on whom coronary artery bypass grafting(CABG) and percutaneous coronary intervention (PCI) cannot be carried out, it has been hemodynamically demonstrated possible to supply arterial blood from the left ventricular cavity to the ischemic myocardium through laser channels. On the basis of excellent experimental studies using mongrel dogs, newly created laser channels 0.2 mm in diameter have been confirmed to be histologically patent even 3 years after transmyocardial revascularization(TMLR). Thus, this method could be applied as an alternative procedure of transmyocardial revascularization. First clinical procedure of TMLR alone was performed on 55 year-old male patient with severe angina pectoris who had undergone pericardiectomy 7 years ago. He had no candidate for percutaneous coronary intervention, or coronary artery bypass grafting, because his left venticle had severe adhesion to the left lung. Therefore, this method was finally carried out. He is getting well after this surgical intervention. This procedure should be recommended for the patient with end-stage coronary artery disease.

  8. New Technique for the Preservation of the Left Common Carotid Artery in Zone 2a Endovascular Repair of Thoracic Aortic Aneurysm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Juszkat, Robert, E-mail: radiologiamim@wp.pl; Kulesza, Jerzy; Zarzecka, Anna

    2011-02-15

    To describe a technique for the preservation of the left common carotid artery (CCA) in zone 2 endovascular repair of thoracic aortic aneurysm. This technique involves the placement of a guide wire into the left CCA via the right brachial artery before stent graft deployment to enable precise visualization and protection of the left CCA during the whole procedure. Of the 107 patients with thoracic endovascular aortic repair in our study, 32 (30%) had the left subclavian artery intentionally covered (landing zone 2). Eight (25%) of those 32 had landing zone 2a-the segment distally the origin of the left CCA,more » halfway between the origin of the left CCA and the left subclavian artery. In all patients, a guide wire was positioned into the left CCA via the right brachial artery before stent graft deployment. It is a retrospective study in design. In seven patients, stent grafts were positioned precisely. In the remaining patient, the positioning was imprecise; the origin of the left CCA was partially covered by the graft. A stent was implanted into the left CCA to restore the flow into the vessel. All procedures were performed successfully. The technique of placing a guide wire into the left CCA via the right brachial artery before stent graft deployment is a safe and effective method that enables the precise visualization of the left CCA during the whole procedure. Moreover, in case of inadvertent complete or partial coverage of the origin of the left CCA, it supplies safe and quick access to the artery for stent implantation.« less

  9. Percutaneous Coronary Intervention for a Patient with Left Main Coronary Compression Syndrome.

    PubMed

    Ikegami, Ryutaro; Ozaki, Kazuyuki; Ozawa, Takuya; Hirono, Satoru; Ito, Masahiro; Minamino, Tohru

    2018-05-15

    Left main coronary compression syndrome rarely occurs in patients with severe pulmonary hypertension. A 65-year-old woman with severe pulmonary hypertension due to an atrial septal defect suffered from angina on effort. Cardiac computed-tomography and coronary angiography revealed considerable stenosis of the left main coronary artery (LMA) caused by compression between the dilated main pulmonary artery trunk and the sinus of valsalva. Stenting of the LMA under intravascular ultrasound imaging was effective for the treatment of angina. We herein report the diagnosis and management of this condition with a brief literature review.

  10. Percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder.

    PubMed

    Xi, Er-Ping; Zhu, Jian; Zhu, Shui-Bo; Yin, Gui-Lin; Liu, Yong; Dong, Yong-Qiang; Zhang, Yu; Xia, Feng

    2012-11-01

    Ventricular septal defects resulting from post-traumatic cardiac injury are very rare. Percutaneous closure has emerged as a method for treating this disorder. We wish to report our experience in three patients who underwent percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder. We treated three patients with post-traumatic ventricular septal defects caused by stab wounds with knives. After the heart wound was repaired, patient examinations revealed ventricular septal defects with pulmonary/systemic flow ratios (Qp/Qs) of over 1.7. The post-traumatic ventricular septal defects were closed percutaneously with a patent ductus arteriosus occluder (Lifetech Scientific (Shenzhen) Co., LTD, Guangdong, China) utilizing standard techniques. Post-operative transthoracic echocardiography revealed no residual left-to-right shunt and indicated normal ventricular function. In addition, 320-slice computerized tomography showed that the occluder was well placed and exhibited normal morphology. Our experiences indicate that closure of a post-traumatic ventricular septal defect using a patent ductus arteriosus occluder is feasible, safe, and effective.

  11. Percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder

    PubMed Central

    Xi, Er-Ping; Zhu, Jian; Zhu, Shui-Bo; Yin, Gui-Lin; Liu, Yong; Dong, Yong-Qiang; Zhang, Yu; Xia, Feng

    2012-01-01

    OBJECTIVE: Ventricular septal defects resulting from post-traumatic cardiac injury are very rare. Percutaneous closure has emerged as a method for treating this disorder. We wish to report our experience in three patients who underwent percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder. METHODS: We treated three patients with post-traumatic ventricular septal defects caused by stab wounds with knives. After the heart wound was repaired, patient examinations revealed ventricular septal defects with pulmonary/systemic flow ratios (Qp/Qs) of over 1.7. The post-traumatic ventricular septal defects were closed percutaneously with a patent ductus arteriosus occluder (Lifetech Scientific (Shenzhen) Co., LTD, Guangdong, China) utilizing standard techniques. RESULTS: Post-operative transthoracic echocardiography revealed no residual left-to-right shunt and indicated normal ventricular function. In addition, 320-slice computerized tomography showed that the occluder was well placed and exhibited normal morphology. CONCLUSION: Our experiences indicate that closure of a post-traumatic ventricular septal defect using a patent ductus arteriosus occluder is feasible, safe, and effective. PMID:23184204

  12. Efficacy of percutaneous treatment of biliary tract calculi using the holmium:YAG laser.

    PubMed

    Hazey, J W; McCreary, M; Guy, G; Melvin, W S

    2007-07-01

    Few Western studies have focused on percutaneous techniques using percutaneous transhepatic choledochoscopy (PTHC) and holmium:yttrium-aluminum-garnet (YAG) laser to ablate biliary calculi in patients unable or unwilling to undergo endoscopic or surgical removal of the calculi. The authors report the efficacy of the holmium:YAG laser in clearing complex biliary calculi using percutaneous access techniques. This study retrospectively reviewed 13 non-Asian patients with complex secondary biliary calculi treated percutaneously using holmium:YAG laser. Percutaneous access was accomplished via left, right, or bilateral hepatic ducts and upsized for passage of a 7-Fr video choledochoscope. Lithotripsy was performed under choledochoscopic vision using a holmium:YAG laser with 200- or 365-microm fibers generating 0.6 to 1.0 joules at 8 to 15 Hz. Patients underwent treatment until stone clearance was confirmed by PTHC. Downsizing and subsequent removal of percutaneous catheters completed the treatment course. Seven men and six women with an average age of 69 years underwent treatment. All the patients had their biliary tract stones cleared successfully. Of the 13 patients, 3 were treated solely as outpatients. The average length of percutaneous access was 108 days. At this writing, one patient still has a catheter in place. The average number of holmium:YAG laser treatments required for stone clearance was 1.6, with no patients requiring more than 3 treatments. Of the 13 patients, 8 underwent a single holmium:YAG laser treatment to clear their calculi. Prior unsuccessful attempts at endoscopic removal of the calculi had been experienced by 7 of the 13 patients. Five patients underwent percutaneous access and subsequent stone removal as their sole therapy for biliary stones. Five patients were cleared of their calculi after percutaneous laser ablation of large stones and percutaneous basket retrieval of the remaining stone fragments. There was one complication of pain requiring admission, and no deaths. The use of PTHC with holmium:YAG laser ablation is safe and efficacious, but requires prolonged biliary access and often multiple procedures to ensure clearance of all calculi.

  13. Orbital atherectomy as an adjunct to debulk difficult calcified lesions prior to mesenteric artery stenting.

    PubMed

    Manunga, Jesse M; Oderich, Gustavo S

    2012-08-01

    To describe a technique in which percutaneous orbital atherectomy is used to debulk heavily calcified superior mesenteric artery (SMA) occlusions as an adjunct in patients undergoing angioplasty and stenting. The technique is demonstrated in a 62-year-old woman with a replaced right hepatic artery originating from an SMA occluded by densely calcified lesions. Via a left transbrachial approach, a 7-F MPA guide catheter was used to engage the ostium of the SMA, which was crossed using a catheter and guidewire. The calcified lesion was debulked using the 2-mm Diamondback 360° orbital atherectomy system. The wire was exchanged for a 0.014-inch filter wire and 0.018-inch guidewire. Using a 2-guidewire technique, the SMA was stented with a self-expanding stent for the distal lesion that crossed side branches and a balloon-expandable stent at the ostium. A 0.014-inch guidewire was placed into the replaced hepatic artery through a cell of the self-expanding stent, followed by deployment of a small balloon-expandable stent to address the residual lesion. The use of orbital atherectomy to debulk occluded and heavily calcified SMA lesions may optimize the technical results with angioplasty and stenting.

  14. Guide Catheter Extension Device Is Effective in Renal Angioplasty for Severely Calcified Lesions

    PubMed Central

    Sugimoto, Takeshi; Nomura, Tetsuya; Hori, Yusuke; Yoshioka, Kenichi; Kubota, Hiroshi; Miyawaki, Daisuke; Urata, Ryota; Kikai, Masakazu; Keira, Natsuya; Tatsumi, Tetsuya

    2017-01-01

    Patient: Male, 69 Final Diagnosis: Atherosclerotic renal artery stenosis Symptoms: None Medication: — Clinical Procedure: — Specialty: Radiology Objective: Unusual setting of medical care Background: The GuideLiner catheter extension device is a monorail-type “Child” support catheter that facilitates coaxial alignment with the guide catheter and provides an appropriate back-up force. This device has been developed in the field of coronary intervention, and now is becoming widely applied in the field of endovascular treatment. However, there has been no report on the effectiveness of the guide catheter extension device in percutaneous transluminal renal angioplasty (PTRA). Case Report: We encountered a case of atherosclerotic subtotal occlusion at the ostium of the left renal artery. Due to the severely calcified orifice and weaker back-up force provided by a JR4 guide catheter, we could not pass any guide-wires through the target lesion. Therefore, we introduced a guide catheter extension device, the GuideLiner catheter, through the guide catheter and achieved good guidewire maneuverability. We finally deployed 2 balloon-expandable stents and successfully performed all PTRA procedures. Conclusions: The guide catheter extension device can be effective in PTRA for severely calcified subtotal occlusion. PMID:28533503

  15. Percutaneous Antegrade Varicocele Embolization Via the Testicular Vein in a Patient with Recurrent Varicocele After Surgical Repair

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guevara, Carlos J., E-mail: guevarac@mir.wustl.edu; El-Hilal, Alexander H., E-mail: elhilala@mir.wustl.edu; Darcy, Michael D., E-mail: darcym@mir.wustl.edu

    This is a case report of an adolescent male who underwent surgical ligation for a left-sided varicocele that recurred 2 years later. Standard retrograde embolization via the left renal vein was not possible, because there was no connection from the renal vein to the gonadal vein following surgical ligation. The patient was treated via antegrade access of the spermatic vein at the inguinal level with subsequent coil embolization.

  16. Reversal of severe mitral regurgitation by device closure of a large patent ductus arteriosus in a premature infant.

    PubMed

    Kheiwa, Ahmed; Ross, Robert D; Kobayashi, Daisuke

    2017-01-01

    We report a critically ill premature infant with severe mitral valve regurgitation associated with pulmonary hypertension and a severely dilated left atrium from a large patent ductus arteriosus. The mitral valve regurgitation improved significantly with normalisation of left atrial size 4 weeks after percutaneous closure of the patent ductus arteriosus. This case highlights the potential reversibility of severe mitral valve regurgitation with treatment of an underlying cardiac shunt.

  17. Inadvertent defibrillator lead placement into the left ventricle after MitraClip implantation: A case report.

    PubMed

    Santarpia, Giuseppe; Passafaro, Francesco; Pasceri, Eugenia; Mongiardo, Annalisa; Curcio, Antonio; Indolfi, Ciro

    2018-05-01

    Inadvertent pacemaker/defibrillator lead placement into the left ventricle is an unusual cardiac device-related complication and its diagnosis is not always easy and often misunderstood. Thromboembolic events are frequently associated with this procedural complication. Percutaneous lead extraction should be performed when diagnosis is made early after device implantation while long-life oral anticoagulation is a wise option when the diagnosis is delayed and the lead is not removed. A 65-year-old man affected by dilated cardiomyopathy, previously treated with a percutaneous mitral valve repair, with 2 MitraClip devices, and later with dual chamber cardioverter/defibrillator implantation, returned in outpatient clinics 2 months after discharge for deterioration of dyspnea; transthoracic echocardiography revealed that the shock lead had been accidentally placed in the apex of the left ventricle. The unintentional lead malposition through the iatrogenic atrial septal defect and its presence into the mitral valve orifice, together with the 2 clip devices implanted, generated an acceleration of transvalvular diastolic flow, determining a moderate stenosis of the mitral valve, as well as promoting a worsening of the degree of valvular regurgitation. Oral anticoagulation therapy was started and a mechanical lead extraction was percutaneously performed. A new defibrillator lead was later appropriately positioned in the apex of the right ventricle. The patient was discharged 3 days after intervention and the follow-up, performed 1 month after discharge, was uneventful. Complex interventional procedures and implantation of multiple devices can increase procedural troubles and the risk of mechanical complications related to pacemaker/defibrillator implantation. Careful observation of the QRS complex morphology on the electrocardiogram (ECG), during paced rhythm, and the achievement of the echocardiographic examination, in the postprocedural phase, allow an early diagnosis of lead malposition.

  18. Percutaneous implantation of a Port-Catheter System using the left subclavian artery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen Yong; He Xiaofeng; Chen Weiguo

    2000-01-15

    Purpose: To evaluate the safety and feasibility of a percutaneous Port-Catheter System (PCS) implanted via the subclavian artery (SCA) for regional chemotherapy or chemoembolization of thoracic, abdominal, and pelvic malignant tumors.Methods: Percutaneous puncture of the SCA was performed in 256 patients with thoracic, abdominal, or pelvic malignant tumors; then a catheter was inserted into the target artery. After the first transcatheter chemotherapy or chemoembolization with an emulsion of lipiodol and anticancer agents, an indwelling catheter was introduced with its tip placed in the target artery and its end subcutaneously connected to a port.Results: The procedure was successfully completed in allmore » 256 cases (100%). The indwelling catheter tip was satisfactorily placed in the target arteries in 242 cases (98%). Complications attributable to the procedure occurred in 20 (7.8%) cases, including pneumothorax (n=10, 4%), hemothorax (n=1, 0.4%), infections in the pocket (n=4, 1.6%), and hematoma at the puncture site (n=5, 2%). There were no severe sequelae or deaths. The duration of PCS usage was 1-36 months (median 9.5 months), During the course of treatment, occlusion of the target artery occurred in 20 cases (7.8%). Dislocation of the tip of the indwelling catheter occurred in 12 cases (4.7%); in 10 of the 12, the tip of the indwelling catheter was repositioned into the target artery. In all 10 cases no large symptomatic hematomas developed after the PCS was removed.Conclusion: Percutaneous PCS implantation via the left SCA, a relatively new procedure, is a safe and less invasive treatment approach than surgical placement for malignancies.« less

  19. Percutaneous Implantation of a Port-Catheter System Using the Left Subclavian Artery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen Yong; He Xiaofeng; Chen Weiguo

    2000-01-15

    Purpose: To evaluate the safety and feasibility of a percutaneous Port-Catheter System (PCS) implanted via the subclavian artery (SCA) for regional chemotherapy or chemoembolization of thoracic, abdominal, and pelvic malignant tumors.Methods: Percutaneous puncture of the SCA was performed in 256 patients with thoracic, abdominal, or pelvic malignant tumors; then a catheter was inserted into the target artery. After the first transcatheter chemotherapy or chemoembolization with an emulsion of lipiodol and anticancer agents, an indwelling catheter was introduced with its tip placed in the target artery and its end subcutaneously connected to a port.Results: The procedure was successfully completed in allmore » 256 cases (100%). The indwelling catheter tip was satisfactorily placed in the target arteries in 242 cases (98%). Complications attributable to the procedure occurred in 20 (7.8%) cases, including pneumothorax (n = 10, 4%), hemothorax (n = 1, 0.4%), infections in the pocket (n = 4, 1.6%), and hematoma at the puncture site (n = 5, 2%). There were no severe sequelae or deaths. The duration of PCS usage was 1-36 months (median 9.5 months). During the course of treatment, occlusion of the target artery occurred in 20 cases (7.8%). Dislocation of the tip of the indwelling catheter occurred in 12 cases (4.7%); in 10 of the 12, the tip of the indwelling catheter was repositioned into the target artery. In all 10 cases no large symptomatic hematomas developed after the PCS was removed.Conclusion: Percutaneous PCS implantation via the left SCA, a relatively new procedure, is a safe and less invasive treatment approach than surgical placement for malignancies.« less

  20. Percutaneous valved stent implantation in the ascending aorta for the treatment of very high-risk aortic regurgitation: an animal study.

    PubMed

    Zong, Gang-Jun; Jiang, Hai-Bin; Bai, Yuan; Wu, Gang-Yong; Ye, Guang-Ming; Chen, Jing-Kai; Qin, Yong-Wen; Zhao, Xian-xian

    2013-12-01

    We investigated the effects of percutaneous valved stent implantation in the ascending aorta as an alternative treatment for aortic regurgitation in a canine model. A total of 16 healthy dogs weighing an average of 18.3 ± 2.1 kg were used for the establishment of animal models of chronic aortic regurgitation by percutaneous aortic valve perforation and balloon dilation. At 2 mo after successful model establishment, all experimental animals underwent valved stent implantation in the ascending aorta and then were followed up for 3 mo. Experimental models of chronic aortic regurgitation were successfully established in 10 dogs. Surviving dogs underwent successful valved stent implantation in the ascending aorta and were subsequently followed up for 3 mo. The level of instantaneous aortic regurgitation at 3-mo follow-up was significantly reduced compared with that before valved stent implantation (2.4 ± 0.9 versus 10.6 ± 2.1 mL/s, P < 0.05). The left ventricular ejection fraction was significantly increased (53.8 ± 4.2% versus 37.8 ± 3.7%, P < 0.05), and the left ventricular end-diastolic volume was also significantly reduced (30.3 ± 2.2 versus 40.1 ± 3.6 mL, P < 0.05). No paravalvular leak, stroke, atrioventricular block, or other complications occurred in dogs undergoing valved stent implantation. Percutaneous valved stent implantation in the ascending aorta is feasible, effective, and safe as an alternative treatment for very high-risk aortic regurgitation in a canine model. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Cangrelor use prior to left ventricular assist device surgery: a case series.

    PubMed

    Washam, Jeffrey B; Yerokun, Babatunde; Patel, Chetan B; Welsby, Ian J; Milano, Carmelo A; DeVore, Adam D

    2018-06-02

    Bleeding frequently occurs in patients undergoing placement of a left ventricular assist device (LVAD). Clinical factors that have been identified as contributing to peri-procedural bleeding include LVAD implantation after an acute myocardial infarction and preoperative use of antiplatelet agents. In this report, we describe the use of cangrelor for preoperative antiplatelet bridging to LVAD in five post myocardial infarction patients with cardiogenic shock that had recently undergone percutaneous coronary intervention. During the cangrelor bridging period, no cases of thrombotic or major bleeding events occurred. During the first week following LVAD implantation, two patients experienced a major bleeding (each case required chest exploration for suspected hemorrhage). To our knowledge, this is the first series describing cangrelor use for antiplatelet bridging in patients undergoing LVAD implantation. While this series suggest cangrelor could possibly be a safe and effective antiplatelet bridging strategy, further research is needed to identify the optimal antithrombotic strategy in cardiogenic shock patients undergoing LVAD implantation who have recently undergoing percutaneous coronary intervention.

  2. Percutaneous transfacial direct embolization of an intraosseous dural arteriovenous fistula.

    PubMed

    Nerva, John D; Hallam, Danial K; Ghodke, Basavaraj V

    2014-03-01

    An intraosseous dural arteriovenous fistula (DAVF) is a rare cerebrovascular disease. The fistulous connection occurs within intraosseous diploic or transosseous emissary veins causing dilated intraosseous vascular pouches. To the authors' knowledge, this report describes the first percutaneous transfacial direct embolization of an intraosseous DAVF. A man in his 50s with blue rubber bleb nevus syndrome presented with headaches, imbalance, decreased visual acuity bilaterally, and left eye proptosis and chemosis. Imaging demonstrated an extensive intraosseous DAVF with dilated intraosseous vascular pouches throughout his cranial base and intraorbital venous congestion. He underwent staged endovascular treatment with the goal to improve his ocular symptoms. Transarterial and transvenous approaches failed to provide adequate access to the intraosseous vascular pouches. A direct, percutaneous transfacial approach was used to access the pouches for embolization with coils and liquid embolic material. Postoperative angiography demonstrated successful embolization of the pouch within the left pterygoid wing, reduced opacification of the intraosseous fistula, and elimination of intraorbital venous congestion. At 9-month follow-up, the patient's headaches had resolved, and his ocular symptomatology had improved. Endovascular access to an intraosseous DAVF is limited by the size and location of the intraosseous vascular pouches. In this case, a direct transfacial approach under image guidance facilitated access and embolization, which led to an improvement in the patient's symptoms. This technique is a novel approach for DAVF management.

  3. Percutaneous mechanical mitral commissurotomy performed with a Cribier's metallic valvulotome. Initial results.

    PubMed

    Bastos, M D; Esteves, C A; Araújo, D; Bastos, L A; Eistein, M; Santana, G P; Oliveira, G J; Brasil, L; Calzada, A; Calzada, D B; Pereira, J; Sales, R; Olivera, N G

    2001-08-01

    To evaluate the immediate results of percutaneous mechanical mitral commissurotomy. Thirty patients underwent percutaneous mechanical mitral commissurotomy performed with a Cribier's metallic valvulotome from 8/11/99 to 2/4/00. Mean age was 30.7 years, and 73.3% were women. With regards to functional class, 63.3% were class III, and 36.7% were class IV. The echocardiographic score had a mean value of 7.5+/- 1.8. The mitral valve area increased from 0.97+/-0.15cm2 to 2.16+/-0.50cm2 (p>0.0001). The mean diastolic gradient decreased from 17.9+/-5.0mmHg to 3.2+/-1.4mmHg. The mean left atrial pressure decreased from 23.6+/-5.4mmHg to 8.6+/-3.1mmHg, (p>0.0001). Systolic pressure in the pulmonary artery decreased from 52.7+/-18.3mmHg to 32.2+/-7.4mmHg. Twenty-nine cases were successful. One patient developed severe mitral regurgitation. Interatrial septal defect was observed and one patient. One patient had cardiac tamponade due to left ventricular perforation. No deaths occurred. This method has proven to be safe and efficient in the treatment of rheumatic mitral stenosis. The potential advantage is that it can be used multiple times after sterilization, which decreases procedural costs significantly.

  4. Left ventricular torsion assessed by two-dimensional echocardiography speckle tracking as a predictor of left ventricular remodeling and short-term outcome following primary percutaneous coronary intervention for acute myocardial infarction: A single-center experience.

    PubMed

    Awadalla, Hany; Saleh, Mohamed Ayman; Abdel Kader, Mohamed; Mansour, Amr

    2017-08-01

    Left ventricular (LV) torsion is a novel method to assess systolic LV function. This study aimed at exploring the utility of 2D speckle tracking-based assessment of left ventricular torsion in patients with acute myocardial infarction (AMI) undertaking primary percutaneous intervention (pPCI) in predicting left ventricular remodeling. The study included 115 patients (mean±SD, age 52.2±9.67, males 84.3%) who underwent pPCI for AMI. Echocardiographic assessment of LV torsion by two-dimensional speckle tracking was performed early after the index pPCI. Patients underwent repeat echocardiography at 6 months to detect remodeling. LV torsion in the acute setting was significantly lower in those who demonstrated LV remodeling at follow-up compared to those without remodeling (7.56±1.95 vs 15.16±4.65; P<.005). Multivariate analysis identified peak CK & CK-MB elevation (β=-0.767 and -0.725; P<.001), SWMA index (β=-0.843; P<.001), and Simpson's derived LV ejection fraction (LVEF; β=0.802; P<.001) as independent predictors of baseline LV torsion. It also identified peak LV torsion (β: 0.27; 95% CI: 0.15-0.5, P=.001) and SWMA index (β: 1.07, 95% CI: 1.03-1.12, P=.005) as independent predictors of LV remodeling. Baseline Killip's grades II and higher (β: 48.6; 95% CI 5.5-428, P<.001) and diabetes mellitus (β: 29.7; 95% CI 1.1-763, P<.05) were independent predictors of mortality. Left ventricular torsion in acute MI setting is impaired and predicts subsequent LV remodeling at 6-month follow-up. © 2017, Wiley Periodicals, Inc.

  5. Global Risk Score and Clinical SYNTAX Score as Predictors of Clinical Outcomes of Patients Undergoing Unprotected Left Main Percutaneous Catheter Intervention

    PubMed Central

    Cuenza, Lucky; Collado, Marianne P.; Ho Khe Sui, James

    2017-01-01

    Background Risk stratification is an important component of left main percutaneous catheter intervention (PCI) which has emerged as a feasible alternative to cardiac surgery. We sought to compare the clinical SYNTAX score and the global risk score in predicting outcomes of patients undergoing unprotected left main PCI in our institution. Methods Clinical, angiographic and procedural characteristics of 92 patients who underwent unprotected left main PCI (mean age 62 ± 12.1 years) were analyzed. Patients were risk stratified into tertiles of high, intermediate and low risk using the global risk score (GRS) and the clinical SYNTAX score (CSS) and were prospectively followed up at 1 year for the occurrence of major adverse cardiovascular events (MACEs), defined as a composite of all cause mortality, cardiac mortality, non-fatal myocardial infarction, stroke, coronary artery bypass, and target vessel revascularization. Results There were 26 (28.2%) who experienced MACEs, of which 10 (10.8%) patients died. Multivariable hazards analysis showed that the GRS (hazard ratio (HR) = 5.5, P = 0.001) and CSS (HR = 4.3, P = 0.001) were both independent predictors of MACEs. Kaplan-Meier analysis showed higher incidence of MACEs with the intermediate and higher risk categories compared to those classified as low risk. Receiver-operator characteristic analysis showed that the GRS has better discriminatory ability than the CSS in the prediction of 1 year MACEs (0.891 vs. 0.743, P = 0.007). Conclusion The GRS and CSS are predictive of outcomes after left main PCI. The GRS appears to have superior predictive and prognostic utility compared to the CSS. This study emphasizes the importance of combining both anatomic and clinical variables for optimum prognostication and management decisions in left main PCI. PMID:29317974

  6. Steam-deformed Judkins-left guiding catheter with use of the GuideLiner(®) catheter to deliver stents for anomalous right coronary artery.

    PubMed

    Kuno, Toshiki; Fujisawa, Taishi; Yamazaki, Hiroyuki; Motoda, Hiroyuki; Kodaira, Masaki; Numasawa, Yohei

    2015-01-01

    Percutaneous coronary intervention for anomalous right coronary artery (RCA) originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin.

  7. Mechanical post-conditioning in STEMI patients undergoing primary percutaneous coronary intervention

    PubMed Central

    Boukhris, Marouane; Bousselmi, Radhouane; Tomasello, Salvatore Davide; Elhadj, Zied Ibn; Azzarelli, Salvatore; Marzà, Francesco; Galassi, Alfredo R.

    2014-01-01

    Although early myocardial reperfusion via primary percutaneous coronary intervention (PCI) allows the preservation of left ventricular function and improves outcome, the acute restoration of blood flow may contribute to the pathophysiology of infarction, a complex phenomenon called reperfusion injury. First described in animal models of coronary obstruction, mechanical post-conditioning, a sequence of repetitive interruption of coronary blood flow applied immediately after reopening of the occluded vessel, was able to reduce the infarct size. However, evidence of its real benefit remains controversial. This review describes the mechanisms of post-conditioning action and the different protocols employed focusing on its impact on primary PCI outcome. PMID:26136633

  8. Iatrogenic left main coronary artery dissection due to pin-hole balloon rupture: Not to be panicked….

    PubMed

    Jeyakumaran, Balakumaran; Raj, Ajay; Pandit, Bhagya Narayan; Kumar, Tarun; Deora, Surender

    2015-12-01

    Iatrogenic left main coronary artery (LMCA) dissection is a rare complication and may have devastating consequences if not immediately intervened. The management includes urgent revascularization mostly with percutaneous coronary intervention (PCI) with bail-out stenting and rarely requires coronary artery bypass graft (CABG) surgery. In clinically and hemodynamically stable patients, a conservative approach may be preferred. Here, we present a rare case of iatrogenic retrograde LMCA dissection due to pin-hole rupture of angioplasty balloon that was managed conservatively.

  9. Percutaneous closure of secundum type atrial septal defects: More than 5-year follow-up

    PubMed Central

    Snijder, Roel JR; Suttorp, Maarten J; Berg, Jurriën M Ten; Post, Martijn C

    2015-01-01

    AIM: To investigate long-term efficacy of two different devices more than five years after percutaneous atrial septal defect (ASD) closure in adults. METHODS: All patients who underwent percutaneous closure of an ASD in the St. Antonius Hospital, Nieuwegein, The Netherlands, between February 1998 and December 2006 were included. Percutaneous closure took place under general anaesthesia and transesophageal echocardiographic monitoring. Transthoracic echocardiography (TTE) was performed 24 h post-procedure to visualize the device position and to look for residual shunting using color Doppler. All complications were registered. All patients were invited for an outpatient visit and contrast TTE more than 5-years after closure. Efficacy was based on the presence of a residual right-to-left shunt (RLS), graded as minimal, moderate or severe. The presence of a residual left-to-right shunt (LRS) was diagnosed using color Doppler, and was not graded. Descriptive statistics were used for patients’ characteristics. Univariate analysis was used to identify predictors for residual shunting. RESULTS: In total, 104 patients (mean age 45.5 ± 17.1 years) underwent percutaneous ASD closure using an Amplatzer device (ASO) in 76 patients and a Cardioseal/Starflex device (CS/SF) in 28 patients. The mean follow-up was 6.4 ± 3.4 years. Device migration occurred in 4 patients of whom two cases occurred during the index hospitalization (1 ASO, 1 CS/SF). The other 2 cases of device migration occurred during the first 6 mo of follow-up (2 CS/SF). The recurrent thrombo-embolic event rate was similar in both groups: 0.4% per follow-up year. More than 12 mo post-ASD closure and latest follow-up, new-onset supraventricular tachyarrhythmia’s occurred in 3.9% and 0% for the ASO and CS/SF group, respectively. The RLS rate at latest follow-up was 17.4% (minimal 10.9%, moderate 2.2%, severe 4.3%) and 45.5% (minimal 27.3%, moderate 18.2%, severe 0%) for the ASO- and CS/SF groups, respectively. There was no residual LRS in both groups. CONCLUSION: Percutaneous ASD closure has good long-term safety and efficacy profiles. The residual RLS rate seems to be high more than 5 years after closure, especially in the CS/SF. Residual LRS was not observed. PMID:25810815

  10. Use of real time three-dimensional transesophageal echocardiography in intracardiac catheter based interventions.

    PubMed

    Perk, Gila; Lang, Roberto M; Garcia-Fernandez, Miguel Angel; Lodato, Joe; Sugeng, Lissa; Lopez, John; Knight, Brad P; Messika-Zeitoun, David; Shah, Sanjiv; Slater, James; Brochet, Eric; Varkey, Mathew; Hijazi, Ziyad; Marino, Nino; Ruiz, Carlos; Kronzon, Itzhak

    2009-08-01

    Real-time three-dimensional (RT3D) echocardiography is a recently developed technique that is being increasingly used in echocardiography laboratories. Over the past several years, improvements in transducer technologies have allowed development of a full matrix-array transducer that allows acquisition of pyramidal-shaped data sets. These data sets can be processed online and offline to allow accurate evaluation of cardiac structures, volumes, and mass. More recently, a transesophageal transducer with RT3D capabilities has been developed. This allows acquisition of high-quality RT3D images on transesophageal echocardiography (TEE). Percutaneous catheter-based procedures have gained growing acceptance in the cardiac procedural armamentarium. Advances in technology and technical skills allow increasingly complex procedures to be performed using a catheter-based approach, thus obviating the need for open-heart surgery. The authors used RT3D TEE to guide 72 catheter-based cardiac interventions. The procedures included the occlusion of atrial septal defects or patent foramen ovales (n=25), percutaneous mitral valve repair (e-valve clipping; n=3), mitral balloon valvuloplasty for mitral stenosis (n=10), left atrial appendage obliteration (n=11), left atrial or pulmonary vein ablation for atrial fibrillation (n=5), percutaneous closures of prosthetic valve dehiscence (n=10), percutaneous aortic valve replacement (n=6), and percutaneous closures of ventricular septal defects (n=2). In this review, the authors describe their experience with this technique, the added value over multiplanar two-dimensional TEE, and the pitfalls that were encountered. The main advantages found for the use RT3D TEE during catheter-based interventions were (1) the ability to visualize the entire lengths of intracardiac catheters, including the tips of all catheters and the balloons or devices they carry, along with a clear depiction of their positions in relation to other cardiac structures, and (2) the ability to ability to demonstrate certain structures in an "en face" view, which is not offered by any other currently available real-time imaging technique, enabling appreciation of the exact nature of the lesion that is undergoing intervention. RT3D TEE is a powerful new imaging tool that may become the technique of choice and the standard of care for guidance of selected percutaneous catheter-based procedures.

  11. Potential Utility of the SYNTAX Score 2 in Patients Undergoing Left Main Angioplasty

    PubMed Central

    Madeira, Sérgio; Raposo, Luís; Brito, João; Rodrigues, Ricardo; Gonçalves, Pedro; Teles, Rui; Gabriel, Henrique; Machado, Francisco; Almeida, Manuel; Mendes, Miguel

    2016-01-01

    Background The revascularization strategy of the left main disease is determinant for clinical outcomes. Objective We sought to 1) validate and compare the performance of the SYNTAX Score 1 and 2 for predicting major cardiovascular events at 4 years in patients who underwent unprotected left main angioplasty and 2) evaluate the long-term outcome according to the SYNTAX score 2-recommended revascularization strategy. Methods We retrospectively studied 132 patients from a single-centre registry who underwent unprotected left main angioplasty between March 1999 and December 2010. Discrimination and calibration of both models were assessed by ROC curve analysis, calibration curves and the Hosmer-Lemeshow test. Results Total event rate was 26.5% at 4 years.The AUC for the SYNTAX Score 1 and SYNTAX Score 2 for percutaneous coronary intervention, was 0.61 (95% CI: 0.49-0.73) and 0.67 (95% CI: 0.57-0.78), respectively. Despite a good overall adjustment for both models, the SYNTAX Score 2 tended to underpredict risk. In the 47 patients (36%) who should have undergone surgery according to the SYNTAX Score 2, event rate was numerically higher (30% vs. 25%; p=0.54), and for those with a higher difference between the two SYNTAX Score 2 scores (Percutaneous coronary intervention vs. Coronary artery by-pass graft risk estimation greater than 5.7%), event rate was almost double (40% vs. 22%; p=0.2). Conclusion The SYNTAX Score 2 may allow a better and individualized risk stratification of patients who need revascularization of an unprotected left main coronary artery. Prospective studies are needed for further validation. PMID:27007223

  12. Percutaneous endovascular therapy for symptomatic chronic total occlusion of the left subclavian artery.

    PubMed

    Akif Cakar, Mehmet; Tatli, Ersun; Tokatli, Alptug; Kilic, Harun; Gunduz, Huseyin; Akdemir, Ramazan

    2018-03-16

    Percutaneous endovascular therapy is an accepted and preferred procedure for symptomatic subclavian artery disease. However, the technical feasibility and effectiveness of treating chronic total occlusion of the subclavian artery with this approach is uncertain. We aimed to evaluate the initial and mid-term results of endovascular therapy for patients with symptomatic chronic total occlusion of the left subclavian artery. Consecutive patients who underwent balloon angioplasty and stenting for chronic total occlusion of the left subclavian artery between January 2010 and February 2014 were included. Overall, 16 patients (10 male, 6 female; mean age 56 ± 13 years) underwent balloon angioplasty and stenting for chronic total occlusion of the left subclavian artery - 6 (37.5%) had arm claudication, 8 (50.0%) had vertebrobasilar insufficiency and 2 (12.5%) had coronary steal. 18 balloon-expandable stents were implanted to 15 patients. The central luminal passage was not achieved in one patient because of the subintimal position of guidewire (procedural success rate 93.8%). There were no procedure-related complications. Mean preprocedural and postprocedural systolic blood pressure differences between the upper extremities were 37 ± 13 (range 25-60) mmHg and 11 ± 9 (range 5-38) mmHg, respectively; the improvement was statistically significant. Outpatient follow-up revealed one asymptomatic restenosis at two years. Patency rate at two years was 93.3%. Balloon angioplasty and stenting for chronic total occlusion of the left subclavian artery is safe and effective, with good acute success rate and mid-term patency. Prospective randomised studies on larger patient populations would provide more precise results.

  13. Flat-Panel Cone-Beam Ct-Guided Radiofrequency Ablation of Very Small (≤1.5 cm) Liver Tumors: Technical Note on a Preliminary Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cazzato, Roberto Luigi, E-mail: r.cazzato@unicampus.it; Buy, Xavier, E-mail: x.buy@bordeaux.unicancer.fr; Alberti, Nicolas, E-mail: nicoalbertibdx@gmail.com

    2015-02-15

    PurposeThe aim of the present study was to investigate the technical feasibility of flat-panel cone-beam CT (CBCT)-guided radiofrequency ablation (RFA) of very small (<1.5 cm) liver tumors.Materials and MethodsPatients included were candidates for hepatic percutaneous RFA as they had single biopsy-proven hepatic tumors sized ≤1.5 cm and poorly defined on ultrasonography. Following apnea induction, unenhanced CBCT scans were acquired and used to deploy the RF electrode with the aid of a virtual navigation system. If the tumor was not clearly identified on the unenhanced CBCT scan, a right retrograde arterial femoral access was established to carry out hepatic angiography and localize themore » tumor. Patients’ lesions and procedural variables were recorded and analyzed.ResultsThree patients (2 male and 1 female), aged 68, 76, and 87 years were included; 3 lesions (2 hepato-cellular carcinoma and 1 metastasis from colorectal cancer) were treated. One patient required hepatic angiography. Cycles of apnea used to acquire CBCT images and to deploy the electrode lasted <120 s. Mean fluoroscopic time needed to deploy the electrode was 36.6 ± 5.7 min. Mean overall procedural time was 66.0 ± 22.9 min. No peri- or post-procedural complications were noted. No cases of incomplete ablation were noted at 1-month follow-up.ConclusionPercutaneous CBCT-guided liver RFA with or without arterial hepatic angiography is technically feasible.« less

  14. Percutaneous closure of patent ductus arteriosus in small infants with significant lung disease may offer faster recovery of respiratory function when compared to surgical ligation.

    PubMed

    Abu Hazeem, Anas A; Gillespie, Matthew J; Thun, Haley; Munson, David; Schwartz, Matthew C; Dori, Yoav; Rome, Jonathan J; Glatz, Andrew C

    2013-10-01

    To describe our experience with percutaneous closure of patent ductus arteriosus (PDA) in small infants and compare outcomes to matched surgical patients. Ligation via thoracotomy has been used to close PDAs in small infants, but has been associated with respiratory and hemodynamic compromise. We hypothesized that percutaneous closure would offer faster recovery of respiratory function. Patients <4 kg requiring positive pressure ventilation who underwent percutaneous PDA closure between January 2000 and April 2012 were reviewed and matched to contemporary surgical patients on gestational age (GA), birth weight (BW), procedure weight (WT), and ventilation mode. Patients returned to baseline respiratory status when the product of mean airway pressure and FiO2 returned to pre-procedural levels. Eight matched pairs were included. Median BW, GA, and WT were 1.43 kg (0.52-2.97), 29.8 weeks (24-39), and 2.8 kg (2.2-3.9) for catheter patients and 1.55 kg (0.48-3.04), 29 weeks (23-37), and 2.75 kg (2.3-4.2) for surgical patients. Complete PDA closure occurred in all. The median time to return to baseline respiratory status was significantly shorter in the percutaneous group (17 hr (range 0-113) vs. 53 hr (range 13-219), P < 0.05). In the percutaneous group, two patients developed mild aortic coarctation, one mild left pulmonary artery stenosis, and four femoral vascular thromboses which all resolved with medical therapy. Surgical complications included significant respiratory and cardiac compromise, rib fractures and urinary retention. Percutaneous closure of PDA in small infants on respiratory support is equivalent in safety and efficacy and may offer shorter recovery time than surgical ligation. Copyright © 2013 Wiley Periodicals, Inc.

  15. Beating Heart Validation of Safety and Efficacy of a Percutaneous Pericardiotomy Tool.

    PubMed

    Killu, Ammar M; Naksuk, Niyada; Desimone, Christopher V; Gaba, Prakriti; Suddendorf, Scott; Powers, Joanne; Ladewig, Dorothy J; Lerman, Lilach O; Borlaug, Barry A; Asirvatham, Samuel J

    2017-03-01

    Epicardial procedures frequently require pericardial manipulation. We aimed to develop a nonsurgical percutaneous pericardial modification tool that may (1) facilitate epicardial-based procedures by enabling adhesiolysis or (2) attenuate the myocardial constraining effect of the pericardium. Three novel devices were developed to enable pericardiotomy, all of which can be deployed in over-the-wire fashion following percutaneous epicardial access. The grasper permits us to seize the pericardial membrane providing leverage for incision. The scissors enables anterograde cutting maneuvers. The reverse-slitter allows retrograde incisions; in addition, this device has a deflectable tip that increases the potential cutting area. We optimized these tools for safety by including electrodes to test for phrenic nerve stimulation as well as myocardial stimulation to determine directionality of the cutting devices. The base of the scissors and reverse-slitter are also blunt ensuring that the cutting element is always away from the myocardium. Following 5 nonbeating heart bench test experiments for prototype development, 11 animal (9 canine, 2 swine) studies were performed. Of these 2 were proof-of-concept open chest studies; the remaining 9 were entirely closed-chest, percutaneous procedures allowing for remodification of the prototypes. The tools successfully permitted incision of the pericardium in all studies. Hemodynamic measurements were assessed postincision and showed no compromise of systolic function. No coronary artery or phrenic nerve damage was seen in any study. Percutaneous pericardiotomy is feasible and appears to be safe. It may provide leverage in epicardial-based procedures and offer treatment options in disease processes characterized by pericardial restraint. © 2016 Wiley Periodicals, Inc.

  16. A Combination of Two Rare Coronary Anomalies Makes It Even Rarer: Right Sided Single Coronary Artery with Dual Left Anterior Descending Artery

    PubMed Central

    Addai, Theodore; Kola, Monahar; Raqeem, Muhammad Wajih; Barsamyan, Sergey; Mirrakhimov, Aibek E.

    2016-01-01

    An 82-year-old female with history of hyperlipidemia and hypertension presented to the clinic with chief complaint of nonradiating chest tightness accompanied by exertional dyspnea. Cardiac catheterization showed the absence of left coronary system; the entire coronary system originated from the right aortic sinus as a common trunk which then gave off the right coronary artery and the left main coronary artery. Cardiac catheterization demonstrated also another rare coronary anomaly: dual left anterior descending artery. Patient underwent percutaneous coronary intervention and subsequent multidetector computed tomography angiography confirmed the above angiography findings. Patient was subsequently discharged home on double antiplatelet therapy with aspirin and clopidogrel and has been asymptomatic since then. PMID:27293909

  17. Center for Innovative Minimally Invasive Therapy

    DTIC Science & Technology

    1999-11-01

    discrete layers within the image. In vivo OCT image of a stent deployed in a swine coronary artery. Shadowing of the metallic stent is seen as areas of...Task 3: Vascular Stent -Grafts Specific Aim 1: Develop novel procedures for the treatment of aneurysms and vascular trauma using percutaneous...applied to coronary anastomoses in chronic studies. One particularly interesting application may be as an external stent to maintain or increase the

  18. Incidence of retrorenal colon during percutaneous nephrolithotomy

    PubMed Central

    Balasar, Mehmet; Kandemir, Abdülkadir; Poyraz, Necdet; Unal, Yunus; Ozturk, Ahmet

    2015-01-01

    Objective The aim of this study was to investigate retrorenal colon incidence in percutaneous nephrolithotomy (PNL) interventions made in our clinic. Materials and Methods Clinical data of 804 PNL patients, accumulated over a 7 year period (2006-2012), was surveyed. The patient files were reviewed retrospectively, and only those who had abdominal computed tomography (CT) images before PNL intervention were included in the study. In the CT images, the position of both the ascending and descending colon in relation to the right and left kidneys were evaluated. Results According to our hospital reports, 394 patients with CT images were included in the present study 27 patients (6.9%) had retrorenal colon, of which 18 (4.6%) were on the left side, 4 (1.0%) on the right side and 5 (1.3%) had bilateral retrorenal colons. Colonic perforation complication was seen only in two patients and the colonic perforation rate was 0.3%. These two cases had no CT images. Conclusions PNL, in the process of becoming the standard treatment modality, is a safe and reliable technique for renal stone treatment. Colonic injury should be taken into consideration during PNL interventions of the lower pole of the kidney (especially on the left side) due to the location of retrorenal colon. PMID:26005968

  19. ANMCO/AIAC/SICI-GISE/SIC/SICCH Consensus Document: percutaneous occlusion of the left atrial appendage in non-valvular atrial fibrillation patients: indications, patient selection, staff skills, organisation, and training

    PubMed Central

    Gulizia, Michele Massimo; Molon, Giulio; Mazzone, Patrizio; Audo, Andrea; Casolo, Giancarlo; Di Lorenzo, Emilio; Portoghese, Michele; Pristipino, Christian; Ricci, Renato Pietro; Themistoclakis, Sakis; Padeletti, Luigi; Tondo, Claudio; Berti, Sergio; Oreglia, Jacopo Andrea; Gerosa, Gino; Zanobini, Marco; Ussia, Gian Paolo; Musumeci, Giuseppe; Romeo, Francesco; Di Bartolomeo, Roberto

    2017-01-01

    Abstract Atrial fibrillation (AF) is the most common arrhythmia and its prevalence is increasing due to the progressive aging of the population. About 20% of strokes are attributable to AF and AF patients are at five-fold increased risk of stroke. The mainstay of treatment of AF is the prevention of thromboembolic complications with oral anticoagulation therapy. Drug treatment for many years has been based on the use of vitamin K antagonists, but recently newer and safer molecules have been introduced (dabigatran etexilate, rivaroxaban, apixaban, and edoxaban). Despite these advances, many patients still do not receive adequate anticoagulation therapy because of contraindications (relative and absolute) to this treatment. Over the last decade, percutaneous closure of left atrial appendage, main site of thrombus formation during AF, proved effective in reducing thromboembolic complications, thus offering a valid medical treatment especially in patients at increased bleeding risk. The aim of this consensus document is to review the main aspects of left atrial appendage occlusion (selection and multidisciplinary assessment of patients, currently available methods and devices, requirements for centres and operators, associated therapies and follow-up modalities) having as a ground the significant evolution of techniques and the available relevant clinical data. PMID:28751849

  20. Steam-deformed Judkins-left guiding catheter with use of the GuideLiner® catheter to deliver stents for anomalous right coronary artery

    PubMed Central

    Kuno, Toshiki; Fujisawa, Taishi; Yamazaki, Hiroyuki; Motoda, Hiroyuki; Kodaira, Masaki; Numasawa, Yohei

    2015-01-01

    Objective: Percutaneous coronary intervention for anomalous right coronary artery (RCA) originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. Methods: We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. Results: We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. Conclusions: We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin. PMID:27489700

  1. Prevalence of patent foramen ovale and usefulness of percutaneous closure device in carcinoid heart disease.

    PubMed

    Mansencal, Nicolas; Mitry, Emmanuel; Pillière, Rémy; Lepère, Céline; Gérardin, Benoît; Petit, Jérôme; Gandjbakhch, Iradj; Rougier, Philippe; Dubourg, Olivier

    2008-04-01

    The aim of this study was to assess (1) the incidence of patent foramen ovale (PFO) in carcinoid syndrome (CS) and (2) the feasibility of percutaneous closure procedure in selected patients with CS. One hundred eight patients were prospectively studied: 54 with CS and an age- and gender-matched control group. All patients underwent conventional and contrast echocardiography. Patients with clinical signs of dyspnea (New York Heart Association class > or =III), cyanosis, carcinoid heart disease (CHD), and severe PFO were referred for the percutaneous closure of PFO. The prevalence of PFO was 41% in patients with CS and 22% in the control group (p = 0.03) and was significantly higher in patients with CHD (59%, p = 0.009). Four patients (14% of those with CHD) were referred for the percutaneous closure of PFO, and 3 patients ultimately underwent PFO closure (using Amplatzer septal occluders). At 6-month follow-up, New York Heart Association class was improved in all patients, as well as arterial blood gas results (p = 0.04) and 6-minute walking distance (p = 0.03), but all patients presented residual right-to-left shunts. In conclusion, this prospective study demonstrates that in patients with CHD, the prevalence of PFO is high and that percutaneous closure of PFO is feasible, with a reduction in symptoms but with residual shunting.

  2. Cardiac troponin I for the prediction of functional recovery and left ventricular remodelling following primary percutaneous coronary intervention for ST-elevation myocardial infarction.

    PubMed

    Hallén, Jonas; Jensen, Jesper K; Fagerland, Morten W; Jaffe, Allan S; Atar, Dan

    2010-12-01

    To investigate the ability of cardiac troponin I (cTnI) to predict functional recovery and left ventricular remodelling following primary percutaneous coronary intervention (pPCI) in ST-elevation myocardial infarction (STEMI). Post hoc study extending from randomised controlled trial. 132 patients with STEMI receiving pPCI. Left ventricular ejection fraction (LVEF), end-diastolic and end-systolic volume index (EDVI and ESVI) and changes in these parameters from day 5 to 4 months after the index event. Cardiac magnetic resonance examination performed at 5 days and 4 months for evaluation of LVEF, EDVI and ESVI. cTnI was sampled at 24 and 48 h. In linear regression models adjusted for early (5 days) assessment of LVEF, ESVI and EDVI, single-point cTnI at either 24 or 48 h were independent and strong predictors of changes in LVEF (p<0.01), EDVI (p<0.01) and ESVI (p<0.01) during the follow-up period. In a logistic regression analysis for prediction of an LVEF below 40% at 4 months, single-point cTnI significantly improved the prognostic strength of the model (area under the curve = 0.94, p<0.01) in comparison with the combination of clinical variables and LVEF at 5 days. Single-point sampling of cTnI after pPCI for STEMI provides important prognostic information on the time-dependent evolution of left ventricular function and volumes.

  3. Transradial percutaneous coronary intervention for left main bifurcation lesions using 7.5-Fr sheathless guide catheter.

    PubMed

    Zhao, Huiqiang; Banerjee, Subhash; Chen, Hui; Li, Hongwei

    2018-05-01

    Recent studies have shown sheathless guide catheters (GCs) to be safe and effective during complex lesions such as bifurcations, chronic total occlusion (CTO), and/or calcified lesions. We investigated the feasibility and safety of using 7.5-Fr sheathless GC for transradial percutaneous coronary intervention (PCI) to treat left main bifurcation lesions.A total of 82 patients were consecutively enrolled from March 2013 to February 2016. They underwent transradial PCI for left main bifurcation lesions using the 7.5-Fr sheathless GC.The mean syntax score was 28.1 ± 6.1, and the majority (n = 55, 67.1%) was intermediate scores (23∼32). The unprotected LM disease was present in 67 of 82 patients (81.7%), and true bifurcation (Medina 1, 1, 1) was present in 46 of 82 patients (56.1%). The 2-stent technique was used in 62 of 82 patients (75.6%). The 2-stent technique included 31 cases (37.8%) of "Crush," 18 cases (22.0%) of "Cullote," and 13 (15.8%) cases of "T stent and modified T stent" (T stent). Immediate angiographic success rate was 100% (82/82), and procedural success rate was 97.6% (80/82). The vascular complications occurred in 3 patients (3/82, 3.7%).The use of 7.5-Fr sheathless GC is safe and allows PCI for complex bifurcation lesions located in the distal of left main to be performed transradially with a high success rate.

  4. Bare-metal stenting of large coronary arteries in ST-elevation myocardial infarction is associated with low rates of target vessel revascularization.

    PubMed

    Shugman, Ibrahim M; Hee, Leia; Mussap, Christian J; Diu, Patrick; Lo, Sidney; Hopkins, Andrew P; Nguyen, Phong; Taylor, David; Rajaratnam, Rohan; Leung, Dominic; Thomas, Liza; Juergens, Craig P; French, John K

    2013-04-01

    During percutaneous coronary intervention (PCI) performed in the emergent setting of ST-segment elevation myocardial infarction (STEMI), uncertainty about patients' ability to comply with 12 months dual antiplatelet therapy after drug-eluting stenting is common, and thus, selective bare-metal stent (BMS) deployment could be an attractive strategy if this achieved low target vessel revascularization (TVR) rates in large infarct-related arteries (IRAs) (≥3.5 mm). To evaluate this hypothesis, among 1,282 patients with STEMI who underwent PCI during their initial hospitalization, we studied 1,059 patients (83%) who received BMS, of whom 512 (48%) had large IRAs ≥3.5 mm in diameter, 333 (31%) had IRAs 3 to 3.49 mm, and 214 (20%) had IRAs <3 mm. At 1 year, TVR rate in patients with BMS was 5.8% (2.2% with large BMS [≥3.5 mm], 9.2% with BMS 3-3.49 mm [intermediate], and 9.0% with BMS <3.0 mm [small], P < .001). The rates of death/reinfarction among patients with large BMS compared with intermediate BMS or small BMS were lower (6.6% vs 11.7% vs 9.0%, P = .042). Among patients who received BMS, the independent predictors of TVR at 1 year were the following: vessel diameter <3.5 mm (odds ratio [OR] 4.39 [95% CI 2.24-8.60], P < .001), proximal left anterior descending coronary artery lesions (OR 1.89 [95% CI 1.08-3.31], P = .027), hypertension (OR 2.01 [95% CI 1.17-3.438], P = .011), and prior PCI (OR 3.46 [95% CI 1.21-9.85], P = .02). The predictors of death/myocardial infarction at 1 year were pre-PCI cardiogenic shock (OR 8.16 [95% CI 4.16-16.01], P < .001), age ≥65 years (OR 2.63 [95% CI 1.58-4.39], P < .001), left anterior descending coronary artery culprit lesions (OR 1.95 [95% CI 1.19-3.21], P = .008), female gender (OR 1.93 [95% CI 1.12-3.32], P = .019), and American College of Cardiology/American Heart Association lesion classes B2 and C (OR 2.17 [95% CI 1.10-4.27], P = .026). Bare-metal stent deployment in STEMI patients with IRAs ≥3.5 mm was associated with low rates of TVR. Their use in this setting warrants comparison with second-generation drug-eluting stenting deployment in future randomized clinical trials. Copyright © 2013 Mosby, Inc. All rights reserved.

  5. Percutaneous Tracheostomy under Bronchoscopic Visualization Does Not Affect Short-Term or Long-Term Complications.

    PubMed

    Easterday, Thomas S; Moore, Joshua W; Redden, Meredith H; Feliciano, David V; Henderson, Vernon J; Humphries, Timothy; Kohler, Katherine E; Ramsay, Philip T; Spence, Stanston D; Walker, Mark; Wyrzykowski, Amy D

    2017-07-01

    Percutaneous tracheostomy is a safe and effective bedside procedure. Some advocate the use of bronchoscopy during the procedure to reduce the rate of complications. We evaluated our complication rate in trauma patients undergoing percutaneous tracheostomy with and without bronchoscopic guidance to ascertain if there was a difference in the rate of complications. A retrospective review of all tracheostomies performed in critically ill trauma patients was performed using the trauma registry from an urban, Level I Trauma Center. Bronchoscopy assistance was used based on surgeon preference. Standard statistical methodology was used to determine if there was a difference in complication rates for procedures performed with and without the bronchoscope. From January 2007, to April 2016, 649 patients underwent modified percuteaneous tracheostomy; 289 with the aid of a bronchoscope and 360 without. There were no statistically significant differences in any type of complication regardless of utilization of a bronchoscope. The addition of bronchoscopy provides several theoretical benefits when performing percutaneous tracheostomy. Our findings, however, do not demonstrate a statistically significant difference in complications between procedures performed with and without a bronchoscope. Use of the bronchoscope should, therefore, be left to the discretion of the performing physician.

  6. Percutaneous closure of acute aorto-right ventricular fistula following transcatheter bicuspid aortic valve replacement.

    PubMed

    Nakamura, Kenta; Passeri, Jonathan J; Inglessis-Azuaje, Ignacio

    2017-07-01

    We report a case of acute aorto-right ventricular fistula following transcatheter bicuspid aortic valve replacement and subsequent percutaneous closure. The diagnosis and treatment of this rare complication is illustrated through multi-modality imaging. We hypothesize that the patient's heavily calcified bicuspid aortic valve anatomy led to asymmetric deployment of the transcatheter aortic valve replacement (TAVR) prosthesis, traumatizing the right sinus of Valsalva at the distal edge of the TAVR stent and ultimately fistulized to the right ventricle. The patient acutely decompensated with heart failure five days after TAVR and underwent emergent intervention. The aorto-right ventricular fistula was closed using an 18-mm septal occluder device with marked clinical recovery. Transcatheter closure is a viable treatment option for acute aorto-right ventricular fistula. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  7. A new self-expandable aortic valved stent deployed above native leaflets for aortic insufficiency: an in vitro study.

    PubMed

    Huang, H; Zhou, Y; Shao, J; Cai, J; Mei, Y; Wang, Y

    2012-12-01

    The aim of this paper was to develop a new self-expandable aortic valved stent following the shape of the sinus of Valsalva, which can be deployed above native leaflets for aortic regurgitation, and study it's effect on coronary artery flow when orthotopic implantation in and above native leaflets. New self-expandable aortic valved stent consist of nitinol stent and bovine pericardium, and was designed following the shape of the sinus of Valsalva, the bovine pericardium was tailed as native leaflet. Thirty-six swine hearts were divided into three equal groups of twelve. In Group A (N.=12), the new self-expandable aortic valved stents deployed in native leaflets. In Group B (N.=12), the new self-expandable aortic valved stents deployed above native leaflets. In Group C (N.=12), the cylinder-like valved stents deployed only in native leaflets. The measurements of each coronary flow rate and endoscopic inspections were repeated post-implantation. In Group A and C, valve implantation in native leaflets resulted in a significant decrease in both left and right coronary flows. In Group B, no significant change in either right or left coronary flow was found after new self-expandable aortic valved stent placement. Endoscopic inspections showed that in group A and C the native leaflets sandwiched between valved stent and aortic wall, whereas, in group B the native leaflets were under the artificial leaflets. Two kinds of stents deployed in native leaflets affect left and right coronary flows significantly. No significant effect was found when the new self-expandable aortic valved stent deployed above native leaflets. This new self-expandable aortic valved stent can be deployed above the native leaflets, which avoids the obstruction of native leaflets on coronary flow.

  8. Clinical outcomes of percutaneous drainage of breast fluid collections following mastectomy with expander-based breast reconstruction

    PubMed Central

    2015-01-01

    PURPOSE To determine clinical outcomes of patients who underwent imaging-guided percutaneous drainage of breast fluid collections following mastectomy and breast reconstruction. MATERIAL AND METHODS Retrospective review included all consecutive patients who underwent percutaneous drainage of fluid collections following mastectomy with tissue expander-based reconstruction between January 2007 and September 2012. A total of 879 mastectomies (563 patients) with expander-based breast reconstruction were performed during this period. 28 patients (5%) developed fluid collections, which led to 30 imaging-guided percutaneous drainage procedures. The median follow up time was 533 days. Patient characteristics, surgical technique, microbiology analysis, and clinical outcomes were reviewed. RESULTS The mean age was 51.5 years (range 30.9 to 69.4 years) and the median time between breast reconstruction and drainage was 35 days (range 4 to 235 days). Erythema and swelling were the most common presenting symptoms. The median volume of fluid evacuated at the time of drain placement was 70 mL. Drains were left in place for a median 14 days (range 6 to 34 days). Microorganisms were detected in the fluid in 12 of 30 drainage procedures, with Staphylococcus aureus being the most common microorganism. No further intervention was needed in 21 of 30 drainage procedures (70%). However, surgical intervention (removal of expanders) was needed following 6 (20%) drainages, and additional percutaneous drainage procedures were performed following 3 (10%) drainages. CONCLUSION Percutaneous drainage is an effective means of treating post operative fluid collections after expander-based breast reconstruction and can obviate the need for repeat surgery in most cases. PMID:23810309

  9. Percutaneous repair or surgery for mitral regurgitation.

    PubMed

    Feldman, Ted; Foster, Elyse; Glower, Donald D; Glower, Donald G; Kar, Saibal; Rinaldi, Michael J; Fail, Peter S; Smalling, Richard W; Siegel, Robert; Rose, Geoffrey A; Engeron, Eric; Loghin, Catalin; Trento, Alfredo; Skipper, Eric R; Fudge, Tommy; Letsou, George V; Massaro, Joseph M; Mauri, Laura

    2011-04-14

    Mitral-valve repair can be accomplished with an investigational procedure that involves the percutaneous implantation of a clip that grasps and approximates the edges of the mitral leaflets at the origin of the regurgitant jet. We randomly assigned 279 patients with moderately severe or severe (grade 3+ or 4+) mitral regurgitation in a 2:1 ratio to undergo either percutaneous repair or conventional surgery for repair or replacement of the mitral valve. The primary composite end point for efficacy was freedom from death, from surgery for mitral-valve dysfunction, and from grade 3+ or 4+ mitral regurgitation at 12 months. The primary safety end point was a composite of major adverse events within 30 days. At 12 months, the rates of the primary end point for efficacy were 55% in the percutaneous-repair group and 73% in the surgery group (P=0.007). The respective rates of the components of the primary end point were as follows: death, 6% in each group; surgery for mitral-valve dysfunction, 20% versus 2%; and grade 3+ or 4+ mitral regurgitation, 21% versus 20%. Major adverse events occurred in 15% of patients in the percutaneous-repair group and 48% of patients in the surgery group at 30 days (P<0.001). At 12 months, both groups had improved left ventricular size, New York Heart Association functional class, and quality-of-life measures, as compared with baseline. Although percutaneous repair was less effective at reducing mitral regurgitation than conventional surgery, the procedure was associated with superior safety and similar improvements in clinical outcomes. (Funded by Abbott Vascular; EVEREST II ClinicalTrials.gov number, NCT00209274.).

  10. Quality of life assessment in the randomized PROTECT AF (Percutaneous Closure of the Left Atrial Appendage Versus Warfarin Therapy for Prevention of Stroke in Patients With Atrial Fibrillation) trial of patients at risk for stroke with nonvalvular atrial fibrillation.

    PubMed

    Alli, Oluseun; Doshi, Shepal; Kar, Saibal; Reddy, Vivek; Sievert, Horst; Mullin, Chris; Swarup, Vijay; Whisenant, Brian; Holmes, David

    2013-04-30

    This study sought to assess quality of life parameters in a subset of patients enrolled in the PROTECT AF (Percutaneous Closure of the Left Atrial Appendage Versus Warfarin Therapy for Prevention of Stroke in Patients With Atrial Fibrillation) trial. The PROTECT AF (Percutaneous Closure of the Left Atrial Appendage Versus Warfarin Therapy for Prevention of Stroke in Patients With Atrial Fibrillation) trial demonstrated that in patients with nonvalvular atrial fibrillation (AF) and CHADS2 (congestive heart failure, hypertension, age, diabetes mellitus, and prior stroke, transient ischemic attack, or thromboembolism) score ≥1, a left atrial appendage closure device is noninferior to long-term warfarin for stroke prevention. Given this equivalency, quality of life (QOL) indicators are an important metric for evaluating these 2 different strategies. QOL using the Short-Form 12 Health Survey, version 2, measurement tool was obtained at baseline and 12 months in a subset of 547 patients in the PROTECT AF trial (361 device and 186 warfarin patients). The analysis cohort consisted of patients for whom either paired quality of life data were available after 12 months of follow-up or for patients who died. With the device, the total physical score improved in 34.9% and was unchanged in 29.9% versus warfarin in whom 24.7% were improved and 31.7% were unchanged (p = 0.01). Mental health improvement occurred in 33.0% of the device group versus 22.6% in the warfarin group (p = 0.06). There was a significant improvement in QOL in patients randomized to device for total physical score, physical function, and in physical role limitation compared to control. There were significant differences in the change in total physical score among warfarin naive and not-warfarin naive subgroups in the device group compared to control, but larger gains were seen with the warfarin naive subgroup with a 12-month change of 1.3 ± 8.8 versus -3.6 ± 6.7 (p = 0.0004) device compared to warfarin. Patients with nonvalvular AF at risk for stroke treated with left atrial appendage closure have favorable QOL changes at 12 months versus patients treated with warfarin. (WATCHMAN Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation [WATCHMAN PROTECT]; NCT00129545). Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  11. Percutaneous coronary intervention vs coronary artery bypass grafting for left main coronary artery disease? A systematic review and meta-analysis of randomized controlled trials.

    PubMed

    Sharma, Sharan P; Dahal, Khagendra; Khatra, Jaspreet; Rosenfeld, Alan; Lee, Juyong

    2017-06-01

    It is not clear whether percutaneous coronary intervention (PCI) is as effective and safe as coronary artery bypass grafting (CABG) for left main coronary artery disease. We aimed to perform a systematic review and meta-analysis of all randomized controlled trials (RCTs) that compared PCI and CABG in left main coronary disease. We searched PubMed, EMBASE, Cochrane, Scopus and relevant references for RCTs (inception through, November 20, 2016 without language restrictions) and performed meta-analysis using random-effects model. All-cause mortality, myocardial infarction, revascularization rate, stroke, and major adverse cardiac and cerebrovascular events (MACCE) were the measured outcomes. Six RCTs with a total population of 4700 were analyzed. There was no difference in all-cause mortality at 30-day, one-year, and five-year (1.8% vs 1.1%; OR 0.60; 95% CI: 0.26-1.39; P=.23; I 2 =9%) follow-up between PCI and CABG. CABG group had less myocardial infarction (MI) at five-year follow-up than PCI (5% vs 2.5%; OR 2.04; CI: 1.30-3.19; P=.002; I 2 =1%). Revascularization rate favored CABG in one-year (8.6% vs 4.5%; OR 2; CI: 1.46-2.73; P<.0001; I 2 =45%) and five-year (15.9% vs 9.9%; OR 1.73; CI: 1.36-2.20; P<.0001; I 2 =0%) follow-up. Although stroke rate was lower in PCI group at 1 year, there was no difference in longer follow-up. MACCE at 5 years favored CABG (24% vs 18%; OR 1.45; CI: 1.19-1.76; P=.0001; I 2 =0%). On subgroup analysis, MACCE were not different between two groups in low-to-intermediate SYNTAX group while it was higher for PCI group with high SYNTAX group. Percutaneous coronary intervention could be as safe and effective as CABG in a select group of left main coronary artery disease patients. © 2017 John Wiley & Sons Ltd.

  12. Percutaneous treatment of Lutembacher syndrome in a case with difficult mitral valve crossing.

    PubMed

    Bhambhani, Anupam; Somanath, H S

    2012-03-01

    Most cases of combination congenital cardiac anomalies are treated with open-heart surgeries because the coexisting anomalies change the cardiac anatomy in an adverse way, making catheter manipulations complex. Lutembacher syndrome is a combination of acquired mitral stenosis and congenital ostium secundum atrial septal defect. The large defect in the septum makes an Inoue balloon catheter unstable, which provides excessive space for free floatation of the catheter, making its passage into the left ventricle difficult by Inoue technique. We present a case of elective definitive percutaneous treatment of Lutembacher syndrome, discussing the technical difficulties faced in mitral valve crossing and reviewing the possible strategies to improve chances of success.

  13. [The scintigraphic 99mTc-MAA imaging quantification of the right-to-left shunt in a patients with multiple pulmonary arteriovenous malformation and familial teleangiectasis].

    PubMed

    Dolezal, J

    2008-02-01

    To present a case report about 57-years-old woman with hypoxemia, multiple pulmonary arteriovenous (AV) malformations and lips teleangiectasis where the right-to-left shunt quantification was assessed by means of whole body scintigraphy with 9mTc-labelled human macro-aggregated albumin (MAA). A 57-years-old woman underwent X-ray and bolus enhanced lung CT for dyspnoea, hypoxemia and cyanosis. A multiple intrapulmonary arteriovenous malformations were detected. The whole-body 99mTc-MAA scintigraphy for the right-to-left shunt quantification was performed. The whole-body scintigraphy in anterior and posterior view was started after intravenous application of 185 MBq 99mTc-MAA. The double-head gamma camera Infinia (General Electric Medical Systems--GE MS) with infrared body countouring and the large field of view was used. The Gamma camera was fitted with low-energy, high resolution, parallel-hole collimator. Images were evaluated by processing system Xeleris (GE MS). The whole-body 99mTc-MAA scintigraphy revealed significant R-L shunt and uptake of radiotracer in extrapulmonary organs (brain, kidney, spleen). The right-to-left shunt ratio was 36%. The woman underwent successful percutaneous transcatheter microembolization treatment. After treatment the woman underwent the next 99mTc-MAA whole-body scintigraphy and the R-L shunt ratio decreased to 17%. The 99mTc-MAA whole-body scintigraphy assessed the right-to-left shunt ratio and improved the management of patients with multiple intrapulmonary A-V malformations. The next 99mTc-MAA scintigraphy after the percutaneous transcatheter microembolization of multiple intrapulmonary A-V malformations confirmed success of treatment.

  14. Comparison of Right and Left Upper Limb Arterial Variants in Patients Undergoing Bilateral Transradial Procedures.

    PubMed

    Burzotta, Francesco; Brancati, Marta Francesca; Porto, Italo; Saffioti, Silvia; Aurigemma, Cristina; Niccoli, Giampaolo; Leone, Antonio Maria; Coluccia, Valentina; Crea, Filippo; Trani, Carlo

    2015-12-01

    Transradial approach (TRA), when compared with transfemoral, improves the safety of percutaneous coronary procedures. Arterial axis variants are known to hinder the performance of transradial approach percutaneous coronary procedures. Data on the occurrence of arterial axis variants in the right and left arm arterial axes of individual patients are lacking. From a single-center prospective registry, we selected all patients in whom bilateral upper limb arterial anatomy was assessed based on the performance of left and right radial catheterization obtained during the same or during repeat coronary diagnostic or interventional procedure(s). The occurrence of upper right and left limb arterial axis variants was classified according to the previously described operative ABC classification. A total of 610 patients were identified. An ABC upper limb arterial axis variant was detected in 156 (25.6%) patients. Variants were right-sided only in 65 (11.0%), left-sided only in 40 (6.6%), and bilateral in 46 (7.5%) patients. Thus, arterial axis variants were significantly more common in the right side (P=0.02). Bilateral arterial variants were significantly associated with age, female sex, and valvulopathy. Both A (radial/brachial) and B (axillary/subclavian/innominate) variants exhibited concordance across the 2 sides (odds ratio, 7.2; 95% confidence interval, 4.1-12.7 and 8.0; 95% confidence interval, 2.1-30.9, respectively). The occurrence of an anatomic variant potentially hindering transradial approach coronary diagnostic or interventional procedures is bilateral in <8% of cases and is more common in the right arm. Such information may guide, during the clinical practice, the access selection in the case of repeat procedures or need for additional accesses. © 2015 American Heart Association, Inc.

  15. [Intracoronary, human autologous stem cell transplantation for myocardial regeneration following myocardial infarction].

    PubMed

    Strauer, B E; Brehm, M; Zeus, T; Gattermann, N; Hernandez, A; Sorg, R V; Kögler, G; Wernet, P

    2001-08-24

    The regenerative potential of human autologous adult stem cells on myocardial regeneration and neovascularisation after myocardial infarction may contribute to healing of the infarction area. But no clinical application has previously been reported. We here describe for the first time the results of this method applied in a patient who had sustained an acute myocardial infarction. 14 hours after the onset of left precordial pain a 46-year-old man was admitted to our hospital for interventional diagnosis and treatment. Coronary angiography demonstrated occlusion of the anterior descending branch of the left coronary artery with transmural infarction. This was treated by percutaneous transluminal catheter angioplasty and stent placement. Mononuclear bone marrow cells of the patient were prepared and 6 days after infaction 1,2 infinity 107 cells were transplanted at low pressure via a percutaneous transluminal catheter placed in the infarct-related artery. Before and 10 weeks after this procedure left ventricular function, infarct size, ventricular geometry and myocardial perfusion were measured by (201)thallium SPECT both at rest and on exercise, together with bull's-eye analysis, dobutamine stress echocardiography, right heart catheterisation and radionuclide ventriculography. At 10 weeks after the stem cell transplantation the transmural infarct area had been reduced from 24.6 % to 15.7 % of left ventricular circumference, while ejection fraction, cardiac index and stroke volume had increased by 20-30 %. On exercise the end diastolic volume had decreased by 30 % and there was a comparable fall in left ventricular filling pressure (mean pulmonary capillary pressure). These results for the first time demonstrate that selective intracoronary transplantation of human autologous adult stem cells is possible under clinical conditions and that it can lead to regeneration of the myocardial scar after transmural infarction. The therapeutic effects may be ascribed to stem cell-associated myocardial regeneration and neovascularisation.

  16. Association of time to reperfusion with left ventricular function and heart failure in patients with acute myocardial infarction treated with primary percutaneous coronary intervention: a systematic review.

    PubMed

    Goel, Kashish; Pinto, Duane S; Gibson, C Michael

    2013-04-01

    Shorter time to reperfusion is associated with a significant reduction in mortality; however, its association with heart failure (HF) is not clearly documented. We conducted a systematic review to examine the association between time to reperfusion and incident HF and/or left ventricular dysfunction. MEDLINE/OVID, EMBASE, Cochrane Library, and Web of Science databases were searched from January 1974 to May 2012 for studies that reported the association between time to reperfusion and incident HF or left ventricular ejection fraction (LVEF) in patients undergoing primary percutaneous coronary intervention. Of 362 nonduplicate abstracts, 71 studies were selected for full-text review. Thirty-three studies were included in the final review, of which 16 were single-center studies, 7 were population-based studies, 7 were subanalyses from randomized controlled trials, and 3 were based on national samples. The pooled data demonstrate that every 1-hour delay in time to reperfusion is associated with a 4% to 12% increased risk of new-onset HF and a 4% relative increase in the risk of incident HF during follow-up. Early reperfusion was associated with a 2% to 8% greater LVEF before discharge and a 3% to 12% larger improvement in absolute LVEF at follow-up compared with the index admission. This systematic review presents evidence that longer time to reperfusion is not only associated with worsened left ventricular systolic function and new-onset HF at the time of index admission, but also with increased risk of HF and reduced improvement in left ventricular systolic function during follow-up. Copyright © 2013 Mosby, Inc. All rights reserved.

  17. Catheter-based intervention for symptomatic patient with severe mitral regurgitation and very poor left ventricular systolic function - Safe but no room for complacency.

    PubMed

    Loh, Poay Huan; Bourantas, Christos V; Chan, Pak Hei; Ihlemann, Nikolaj; Gustafsson, Fin; Clark, Andrew L; Price, Susanna; Mario, Carlo Di; Moat, Neil; Alamgir, Farqad; Estevez-Loureiro, Rodrigo; Søndergaard, Lars; Franzen, Olaf

    2015-11-26

    Many patients with left ventricular systolic dysfunction have concomitant mitral regurgitation (MR). Their symptoms and prognosis worsen with increasing severity of MR. Percutaneous MitraClip(®) can be used safely to reduce the severity of MR even in patients with advanced heart failure and is associated with improved symptoms, quality of life and exercise tolerance. However, a few patients with very poor left ventricular systolic function may experience significant haemodynamic disturbance in the peri-procedural period. We present three such patients, highlighting some of the potential problems encountered and discuss their possible pathophysiological mechanisms and safety measures.

  18. Catheter-based intervention for symptomatic patient with severe mitral regurgitation and very poor left ventricular systolic function - Safe but no room for complacency

    PubMed Central

    Loh, Poay Huan; Bourantas, Christos V; Chan, Pak Hei; Ihlemann, Nikolaj; Gustafsson, Fin; Clark, Andrew L; Price, Susanna; Mario, Carlo Di; Moat, Neil; Alamgir, Farqad; Estevez-Loureiro, Rodrigo; Søndergaard, Lars; Franzen, Olaf

    2015-01-01

    Many patients with left ventricular systolic dysfunction have concomitant mitral regurgitation (MR). Their symptoms and prognosis worsen with increasing severity of MR. Percutaneous MitraClip® can be used safely to reduce the severity of MR even in patients with advanced heart failure and is associated with improved symptoms, quality of life and exercise tolerance. However, a few patients with very poor left ventricular systolic function may experience significant haemodynamic disturbance in the peri-procedural period. We present three such patients, highlighting some of the potential problems encountered and discuss their possible pathophysiological mechanisms and safety measures. PMID:26635930

  19. Predictors of Long-Term Results After Treatment of Iliac Artery Obliteration by Transluminal Angioplasty and Stent Deployment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Funovics, M.A.; Lackner, B.; Cejna, M.

    2002-10-15

    Purpose: To investigate initial and long-term success rate after percutaneous treatment of iliac artery occlusion with angioplasty and stent deployment. To investigate the influence of vascular comorbidity, lesion length, stent placement and lesion coverage as possible predictors of outcome. Methods: Between January 1994 and December 1999, 80 iliac recanalizations were performed on 78 patients, median age 61.1 {+-}11.5 (SD) years. All patients were followed up by clinical examinations, duplex ultrasound and intravenous digital subtraction angiography. Mean follow-up time was 2.0 {+-} 1.53 (SD) years.Multivariate Cox regression analysis was used to determine the influence of cofactors on patency. Results: One, 2more » and 4 years after recanalization, primary patency was 78.1%, 74.5% and 64.0%; secondary patency was 88.8%, 88.8% and 77.9%, respectively.Patients with shorter occlusions, complete lesion coverage and patent ipsilateral femoral arteries had significantly longer patency rates.Complications included inguinal hematoma (n=1), technical failure (n=3) aortic dissection (n=1), embolic occlusions (n=7), gluteal claudication (n=1) and genital necrosis after subsequent urethral surgery in one patient with contralateral occlusion and ipsilateral overstenting of the internal iliac artery with subsequent stenosis. Complications were of permanent clinical significance in seven of 78 (9%) of the patients. In 17 (22%) cases, percutaneous reintervention was performed with angioplasty in the stent (n=16) or deployment of a new stent (n=1). Conclusion: Endoluminal stent placement has its place in an interdisciplinary therapeutic approach as a viable therapeutic alternative to major transabdominal bypass surgery and can be performed with comparable complication rates. Patients with short occlusions, patent femoral arteries, and stents covering the entire occlusion have significant longer patency.« less

  20. Percutaneous closure of the left atrial appendage for prevention of thromboembolism in atrial fibrillation for patients with contraindication to or failure of oral anticoagulation: a single-center experience.

    PubMed

    Faustino, Ana; Paiva, Luís; Providência, Rui; Trigo, Joana; Botelho, Ana; Costa, Marco; Leitão-Marques, António

    2013-06-01

    In non-valvular atrial fibrillation 90% of thrombi originate in the left atrial appendage (LAA). Percutaneous LAA closure has been shown to be non-inferior to warfarin for prevention of thromboembolism. To evaluate the initial experience of a single center in percutaneous LAA closure in patients with high thromboembolic risk and in whom oral anticoagulation was impractical or contraindicated or had failed. Patients with non-valvular atrial fibrillation and CHADS2 score ≥2 in whom oral anticoagulation was impractical or contraindicated or had failed underwent percutaneous LAA closure according to the standard technique. After the procedure, dual antiplatelet therapy was maintained for one month, followed by single antiplatelet therapy indefinitely. Patients were followed by clinical assessment and transthoracic and transesophageal echocardiography. The procedure was performed in 22 of the 23 selected patients (95.7%), mean age 70±9 years, CHADS2 score 3.2±0.9 and CHA2DS2-VASC score 4.7±1.4. Intraprocedural device replacement was necessary only in the first patient, due to oversizing. The following periprocedural complications were observed: one femoral pseudoaneurysm, three femoral hematomas and two minor oropharyngeal bleeds, resolved by local hemostatic measures. During a 12±8 month follow-up a mild peri-device flow and a thrombus adhering to the device, resolved under with enoxaparin therapy, were identified. The rate of transient ischemic attack (TIA)/stroke was lower than expected according to the CHADS2 score (0 vs. 6.7±2.2%). In our initial experience, this procedure proved to be a feasible, safe and effective alternative for atrial fibrillation patients in whom oral anticoagulation is not an option. Only relatively minor complications were observed, with a lower than expected TIA/stroke rate. Copyright © 2012 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  1. Catheter closure of patent foramen ovale in patients with cryptogenic cerebrovascular accidents: initial experiences in Japan.

    PubMed

    Kijima, Yasufumi; Akagi, Teiji; Nakagawa, Koji; Taniguchi, Manabu; Ueoka, Akira; Deguchi, Kentaro; Toh, Norihisa; Oe, Hiroki; Kusano, Kengo; Sano, Shunji; Ito, Hiroshi

    2014-01-01

    Although numerous studies have shown an association between a patent foramen ovale (PFO) and cryptogenic cerebrovascular accidents (CVA), there has been no definitive control study that demonstrated the benefit of percutaneous device closure of a PFO compared to medical therapy in patients with CVA. Additionally, few clinical data exist for Japanese patients in this field. We demonstrate the initial experiences in catheter closure of a PFO as secondary prevention of CVA in Japan. Catheter closure of a PFO was attempted in 7 patients who were diagnosed with cryptogenic CVA. Mean age at the procedure was 54 ± 19 years. The presence of spontaneous interatrial right-to-left shunts was demonstrated by transesophageal contrast echocardiography without Valsalva maneuver in all of the patients. Amplatzer Cribriform device (n = 4) or Amplatzer PFO Occluder (n = 3) was used for the procedure and was successfully deployed. Device-related complications were not observed at the time of the procedure or during the follow-up period (mean period of 16 ± 9 months). Catheter closure of a PFO could be safely performed with Amplatzer Cribriform or Amplatzer PFO Occluder. This procedure may contribute to prevention of recurrent cryptogenic CVA in Japanese patients.

  2. Diffuse large B-cell non-Hodgkin lymphoma involving the unilateral carotid space in an elderly man: A case report.

    PubMed

    Chen, Bo; Zou, Chunying; Wu, Jianqing

    2017-01-01

    An 84-year-old man presented with a history of repeated syncope and decreased heart rate and blood pressure over the last month. On physical examination, a mass sized ~3×3 cm was palpable in the left submandibular area; the mass was hard, poorly mobile, without tenderness or local skin irritation. The computed tomography angiography examination revealed a soft tissue mass in the neck, at the level of the left carotid bifurcation and above. The left common carotid artery bifurcation and internal and external carotid artery segment were embedded in the mass, and there were multiple enlarged lymph nodes in the left neck. The diagnosis of diffuse large B-cell non-Hodgkin lymphoma was confirmed by a percutaneous biopsy of the left submandibular mass. To the best of our knowledge, this is the first reported case of non-Hodgkin lymphoma involvign the carotid space.

  3. Percutaneous Transcatheter Interventions for Aortic Insufficiency in Continuous-Flow Left Ventricular Assist Device Patients: A Systematic Review and Meta-Analysis.

    PubMed

    Phan, Kevin; Haswell, Joshua M; Xu, Joshua; Assem, Yusuf; Mick, Stephanie L; Kapadia, Samir R; Cheung, Anson; Ling, Frederick S; Yan, Tristan D; Tchantchaleishvili, Vakhtang

    De novo progressive aortic insufficiency (AI) is a side effect frequently related to prolonged support with continuous-flow left ventricular assist devices (CF-LVAD). Its progression can result in recurrent clinical heart failure symptoms and significantly increased mortality. Recently, percutaneous intervention methods, such as transcatheter aortic valve replacement (TAVR) and percutaneous occluder devices, have emerged. However, given the very scarce global experience with these approaches, evidence in the literature is lacking. We sought to assess the outcomes of CF-LVAD patients who had undergone percutaneous intervention for AI. A systematic search of six databases from inception to April 2016 was performed by two independent reviewers. Eligible studies were those that included series or cases where patients had percutaneous transcatheter interventions for AI in CF-LVAD patients. Data were extracted and meta-analyzed from the identified studies. A total of 29 patients from 15 published studies and 3 unpublished records were included in the analysis. Mean patient age was 56.6 ± 13.7 years, and 72.4% were male. The etiology of heart failure resulting in LVAD placement was ischemic cardiomyopathy in 17.2%. The two intervention groups were TAVR (27.6%) and occluder devices (72.4%). A transfemoral approach (69%), apical approach (10%), brachial approach (7%), subclavian approach (3%), and mini-sternotomy (3%) were used. The preintervention AI grade was severe with a median grade of 4 (interquartile range, 4-4). Postoperatively, the AI grade improved significantly to a median grade of 0 (0-2). At long-term follow-up AI grade was still trivial with a median AI grade of 1 (0-1). Subgrouping the treatments into the occluder device and TAVR, it was found that both interventional techniques were similarly effective in reducing the AI grade from severe to trivial. In terms of complications, from the occluder group, two patients were complicated with device migration and another two with transient hemolysis. In the TAVR cohort, two patients experienced device migration and another had significant postimplant perivalvular leakage. Our results indicate that percutaneous interventions for AI in CF-LVAD patients with TAVR, and closure devices demonstrate similar efficacy in significantly reducing severe AI. Current results are encouraging, potentiating viability as a treatment option, particularly in nonsurgical candidates. Future research with larger patient cohorts and comparative controls is required to sufficiently evaluate the efficacy of this technique and promote its widespread acceptance as a mainstay treatment.

  4. Percutaneous endoscopic holmium laser lithotripsy for management of complicated biliary calculi.

    PubMed

    Healy, Kelly; Chamsuddin, Abbas; Spivey, James; Martin, Louis; Nieh, Peter; Ogan, Kenneth

    2009-01-01

    Advances in endoscopic techniques have transformed the management of urolithiasis. We sought to evaluate the role of such urological interventions for the treatment of complex biliary calculi. We conducted a retrospective review of all patients (n=9) undergoing percutaneous holmium laser lithotripsy for complicated biliary calculi over a 4-year period (12/2003 to 12/2007). All previously failed standard techniques include ERCP with sphincterotomy (n=6), PTHC (n=7), or both of these. Access to the biliary system was obtained via an existing percutaneous transhepatic catheter or T-tube tracts. Endoscopic holmium laser lithotripsy was performed via a flexible cystoscope or ureteroscope. Stone clearance was confirmed intra- and post-operatively. A percutaneous transhepatic drain was left indwelling for follow-up imaging. Mean patient age was 65.6 years (range, 38 to 92). Total stone burden ranged from 1.7 cm to 5 cm. All 9 patients had stones located in the CBD, with 2 patients also having additional stones within the hepatic ducts. All 9 patients (100%) were visually stone-free after one endoscopic procedure. No major perioperative complications occurred. Mean length of stay was 2.4 days. At a mean radiological follow-up of 5.4 months (range, 0.5 to 21), no stone recurrence was noted. Percutaneous endoscopic holmium laser lithotripsy is a minimally invasive alternative to open salvage surgery for complex biliary calculi refractory to standard approaches. This treatment is both safe and efficacious. Success depends on a multidisciplinary approach.

  5. Percutaneous Endoscopic Holmium Laser Lithotripsy for Management of Complicated Biliary Calculi

    PubMed Central

    Healy, Kelly; Chamsuddin, Abbas; Spivey, James; Martin, Louis; Nieh, Peter

    2009-01-01

    Background and Objectives: Advances in endoscopic techniques have transformed the management of urolithiasis. We sought to evaluate the role of such urological interventions for the treatment of complex biliary calculi. Methods: We conducted a retrospective review of all patients (n=9) undergoing percutaneous holmium laser lithotripsy for complicated biliary calculi over a 4-year period (12/2003 to 12/2007). All previously failed standard techniques include ERCP with sphincterotomy (n=6), PTHC (n=7), or both of these. Access to the biliary system was obtained via an existing percutaneous transhepatic catheter or T-tube tracts. Endoscopic holmium laser lithotripsy was performed via a flexible cystoscope or ureteroscope. Stone clearance was confirmed intra- and postoperatively. A percutaneous transhepatic drain was left indwelling for follow-up imaging. Results: Mean patient age was 65.6 years (range, 38 to 92). Total stone burden ranged from 1.7 cm to 5 cm. All 9 patients had stones located in the CBD, with 2 patients also having additional stones within the hepatic ducts. All 9 patients (100%) were visually stone-free after one endoscopic procedure. No major perioperative complications occurred. Mean length of stay was 2.4 days. At a mean radiological follow-up of 5.4 months (range, 0.5 to 21), no stone recurrence was noted. Conclusions: Percutaneous endoscopic holmium laser lithotripsy is a minimally invasive alternative to open salvage surgery for complex biliary calculi refractory to standard approaches. This treatment is both safe and efficacious. Success depends on a multidisciplinary approach. PMID:19660213

  6. Percutaneous computer-assisted translaminar facet screw: an initial human cadaveric study.

    PubMed

    Sasso, Rick C; Best, Natalie M; Potts, Eric A

    2005-01-01

    Translaminar facet screws are a minimally invasive technique for posterior lumbar fixation with good success rates. Computer-assisted image navigation using virtual fluoroscopy allows multiple simultaneous screens in various planes to plan and drive spinal instrumentation. This study evaluates the percutaneous placement of translaminar facet screws with the use of virtual fluoroscopy as an image guidance technique. A human cadaveric study was performed with a percutaneous reference frame applied to the iliac crest. Ten translaminar facet screws were placed bilaterally at five levels. Anteroposterior and lateral images were used to navigate 4.0-mm screws through a percutaneous portal under virtual fluoroscopy. An axial computed tomographic scan through the instrumented levels was obtained after the screws were placed. Screws were graded on entry, course through the lamina, and terminus. A grading system was devised to grade the course through the lamina. All 10 screw-entry points were judged optimal at the spinous process laminar junction. There were five Grade I breeches with less than 1/2 the screw through the lamina, and five Grade 0 screw placements with the screw contained completely within the lamina. The termination point was acceptable in five screws. The screws that began on the right and terminated on the left were all found to have grade II breakouts. No screws placed the spinal canal or exiting nerve root at risk. Virtual fluoroscopy provides significant assistance in percutaneous placement of translaminar facet screws and results in safe position of entry, lamina course, and terminus.

  7. In-Bore Prostate Transperineal Interventions with an MRI-guided Parallel Manipulator: System Development and Preliminary Evaluation

    PubMed Central

    Eslami, Sohrab; Shang, Weijian; Li, Gang; Patel, Nirav; Fischer, Gregory S.; Tokuda, Junichi; Hata, Nobuhiko; Tempany, Clare M.; Iordachita, Iulian

    2015-01-01

    Background The robot-assisted minimally-invasive surgery is well recognized as a feasible solution for diagnosis and treatment of the prostate cancer in human. Methods In this paper the kinematics of a parallel 4 Degrees-of-Freedom (DOF) surgical manipulator designed for minimally invasive in-bore prostate percutaneous interventions through the patient's perineum. The proposed manipulator takes advantage of 4 sliders actuated by MRI-compatible piezoelectric motors and incremental rotary encoders. Errors, mostly originating from the design and manufacturing process, need to be identified and reduced before the robot is deployed in the clinical trials. Results The manipulator has undergone several experiments to evaluate the repeatability and accuracy of the needle placement which is an essential concern in percutaneous prostate interventions. Conclusion The acquired results endorse the sustainability, precision (about 1 mm in air (in x or y direction) at the needle's reference point) and reliability of the manipulator. PMID:26111458

  8. Percutaneous intracardiac beating-heart surgery using metal MEMS tissue approximation tools

    PubMed Central

    Gosline, Andrew H; Vasilyev, Nikolay V; Butler, Evan J; Folk, Chris; Cohen, Adam; Chen, Rich; Lang, Nora; del Nido, Pedro J; Dupont, Pierre E

    2013-01-01

    Achieving superior outcomes through the use of robots in medical applications requires an integrated approach to the design of the robot, tooling and the procedure itself. In this paper, this approach is applied to develop a robotic technique for closing abnormal communication between the atria of the heart. The goal is to achieve the efficacy of surgical closure as performed on a stopped, open heart with the reduced risk and trauma of a beating-heart catheter-based procedure. In the proposed approach, a concentric tube robot is used to percutaneously access the right atrium and deploy a tissue approximation device. The device is constructed using a metal microelectromechanical system (MEMS) fabrication process and is designed to both fit the manipulation capabilities of the robot as well as to reproduce the beneficial features of surgical closure by suture. The effectiveness of the approach is demonstrated through ex vivo and in vivo experiments. PMID:23750066

  9. Comparison of left ventricular diastolic function in obstructive hypertrophic cardiomyopathy in patients undergoing percutaneous septal alcohol ablation versus surgical myotomy/myectomy

    NASA Technical Reports Server (NTRS)

    Sitges, Marta; Shiota, Takahiro; Lever, Harry M.; Qin, Jian Xin; Bauer, Fabrice; Drinko, Jeannie K.; Agler, Deborah A.; Martin, Maureen G.; Greenberg, Neil L.; Smedira, Nicholas G.; hide

    2003-01-01

    Both percutaneous transcoronary alcohol septal reduction (ASR) and surgical myectomy are effective treatments to relieve left ventricular (LV) outflow tract obstruction in obstructive hypertrophic cardiomyopathy (HC). LV diastolic function was assessed by echocardiography in 57 patients with obstructive HC at baseline and 5 +/- 4 months after ASR (n = 37) or surgical myectomy (n = 20). LV outflow tract pressure gradient decreased from 65 +/- 40 to 23 +/- 21 mm Hg (p <0.01) after treatment. The ratio of the early-to-late peak diastolic LV inflow velocities, and the ratio of the early peak diastolic LV inflow velocity to the lateral mitral annulus early diastolic velocity determined by tissue Doppler imaging significantly decreased after the procedures (1.6 +/- 1.7 vs 1.0 +/- 0.7 and 15 +/- 8 vs 11 +/- 5, respectively), whereas LV inflow propagation velocity significantly increased (60 +/- 24 vs 71 +/- 36 cm/s). Left atrial size decreased from 29 +/- 7 to 25 +/- 6 cm(2) (p <0.05). Patients had a significant improvement in New York Heart Association functional class and in exercise performance. When comparing ASR with myectomy, no difference was found in the degree of change in any parameter of diastolic function. Thus, diastolic function indexes obtained by echocardiography changed after septal reduction interventions in patients with obstructive HC; this change was similar to that after surgical myectomy and ASR.

  10. Resolution of massive left atrial appendage thrombi with rivaroxaban before balloon mitral commissurotomy in severe mitral stenosis: A case report and literature review.

    PubMed

    Li, Yuechun; Lin, Jiafeng; Peng, Chen

    2016-12-01

    Data on nonvitamin K antagonist oral anticoagulant being used for the treatment of LAA thrombi are limited only in nonvalvular atrial fibrillation. There are no data on the antithrombotic efficacy and safety of nonvitamin K antagonist oral anticoagulant in the resolution of left atrial appendage (LAA) thrombi in patients with rheumatic mitral stenosis. A 49-year-old woman with known rheumatic mitral stenosis and atrial fibrillation was referred for percutaneous transvenous mitral commissurotomy because of progressive dyspnea on exertion over a period of 3 months. Transesophageal echocardiography (TEE) demonstrated a large LAA thrombus protruding into left atria cavity before the procedure. Direct factor Xa (FXa) inhibitor rivaroxaban (20 mg/d) was started for the patient. After 3 weeks of rivaroxaban treatment TEE showed a relevantly decreased thrombus size, and a complete thrombus resolution was achieved after 5 weeks of anticoagulant therapy with the FXa inhibitor. To the best of our knowledge, this is the first documented case of large LAA thrombus resolution with nonvitamin K antagonist oral anticoagulant in severe mitral stenosis, and in which percutaneous transvenous mitral commissurotomy was performed subsequently. The report indicated that rivaroxaban could be a therapeutic option for mitral stenosis patients with LAA thrombus. Further study is required before the routine use of rivaroxaban in patients with rheumatic mitral stenosis and atrial fibrillation.

  11. Tricuspid valve and percutaneous approach: No longer the forgotten valve!

    PubMed

    Bouleti, Claire; Juliard, Jean-Michel; Himbert, Dominique; Iung, Bernard; Brochet, Eric; Urena, Marina; Dilly, Marie-Pierre; Ou, Phalla; Nataf, Patrick; Vahanian, Alec

    2016-01-01

    Tricuspid valve disease is mainly represented by tricuspid regurgitation (TR), which is a predictor of poor outcome. TR is usually secondary, caused by right ventricle pressure or volume overload, the leading cause being left-sided heart valve diseases. Tricuspid surgery for severe TR is recommended during left valve surgery, and consists of either a valve replacement or, most often, a tricuspid repair with or without prosthetic annuloplasty. When TR persists or worsens after left valvular surgery, redo isolated tricuspid surgery is associated with high mortality. In addition, a sizeable proportion of patients present with tricuspid surgery deterioration over time, and need a reintervention, which is associated with high morbi-mortality rates. In this context, and given the recent major breakthrough in the percutaneous treatment of aortic and mitral valve diseases, the tricuspid valve appears an appealing challenge, although it raises specific issues. The first applications of transcatheter techniques for tricuspid valve disease were valve-in-valve and valve-in-ring implantation for degenerated bioprosthesis or ring annuloplasty. Some concerns remain regarding prosthesis sizing, rapid ventricular pacing and the best approach, but these procedures appear to be safe and effective. More recently, bicuspidization using a transcatheter approach for the treatment of native tricuspid valve has been published, in two patients. Finally, other devices are in preclinical development. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  12. The American Satellite Company (ASC) satellite deployed from payload bay

    NASA Technical Reports Server (NTRS)

    1985-01-01

    The American Satellite Company (ASC) communications satellite is deployed from the payload bay of the Shuttle Discovery. A portion of the cloudy surface of the earth can be seen to the left of the frame.

  13. Ethical challenges with the left ventricular assist device as a destination therapy

    PubMed Central

    Rizzieri, Aaron G; Verheijde, Joseph L; Rady, Mohamed Y; McGregor, Joan L

    2008-01-01

    The left ventricular assist device was originally designed to be surgically implanted as a bridge to transplantation for patients with chronic end-stage heart failure. On the basis of the REMATCH trial, the US Food and Drug Administration and the US Centers for Medicare & Medicaid Services approved permanent implantation of the left ventricular assist device as a destination therapy in Medicare beneficiaries who are not candidates for heart transplantation. The use of the left ventricular assist device as a destination therapy raises certain ethical challenges. Left ventricular assist devices can prolong the survival of average recipients compared with optimal medical management of chronic end-stage heart failure. However, the overall quality of life can be adversely affected in some recipients because of serious infections, neurologic complications, and device malfunction. Left ventricular assist devices alter end-of-life trajectories. The caregivers of recipients may experience significant burden (e.g., poor physical health, depression, anxiety, and posttraumatic stress disorder) from destination therapy with left ventricular assist devices. There are also social and financial ramifications for recipients and their families. We advocate early utilization of a palliative care approach and outline prerequisite conditions so that consenting for the use of a left ventricular assist device as a destination therapy is a well informed process. These conditions include: (1) direct participation of a multidisciplinary care team, including palliative care specialists, (2) a concise plan of care for anticipated device-related complications, (3) careful surveillance and counseling for caregiver burden, (4) advance-care planning for anticipated end-of-life trajectories and timing of device deactivation, and (5) a plan to address the long-term financial burden on patients, families, and caregivers. Short-term mechanical circulatory devices (e.g. percutaneous cardiopulmonary bypass, percutaneous ventricular assist devices, etc.) can be initiated in emergency situations as a bridge to permanent implantation of ventricular assist devices in chronic end-stage heart failure. In the absence of first-person (patient) consent, presumed consent or surrogate consent should be used cautiously for the initiation of short-term mechanical circulatory devices in emergency situations as a bridge to permanent implantation of left ventricular assist devices. Future clinical studies of destination therapy with left ventricular assist devices should include measures of recipients' quality of end-of-life care and caregivers' burden. PMID:18694496

  14. Failure and Success of Percutaneous Angioplasty in a Hypertensive Child with Bilateral Renal Artery Stenosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giavroglou, Constantinos; Tsifountoudis, Ioannis, E-mail: jtsif@mycosmos.g; Boutzetis, Theodoros

    2009-01-15

    We describe the clinical course of a 5-year-old girl with severe arterial hypertension that was uncontrollable with antihypertensive medication. Renal angiography revealed bilateral renal artery stenoses. Because percutaneous transluminal renal angioplasty (PTRA) failed to dilate the stenotic lesions, a renal artery bypass grafting in both renal arteries was performed. The patient remained normotensive for 7 months, and after that the arterial pressure increased again. Digital subtraction angiography demonstrated stenosis at the peripheral and central anastomosis of the vein graft that was used for revascularization of the left kidney. PTRA was decided on and successful patency was achieved. The patient hasmore » now been normotensive for a period of 5 years.« less

  15. Contrast‐enhanced computed tomography with myocardial three‐dimensional printing can guide treatment in symptomatic hypertrophic obstructive cardiomyopathy

    PubMed Central

    Hamatani, Yasuhiro; Amaki, Makoto; Kanzaki, Hideaki; Yamashita, Kizuku; Nakashima, Yasuteru; Shibata, Atsushi; Okada, Atsushi; Takahama, Hiroyuki; Hasegawa, Takuya; Shimahara, Yusuke; Sugano, Yasuo; Fujita, Tomoyuki; Shiraishi, Isao; Yasuda, Satoshi; Kobayashi, Junjiro

    2017-01-01

    Abstract Both surgical myectomy and percutaneous transluminal septal myocardial ablation are effective treatments for drug‐refractory symptomatic hypertrophic obstructive cardiomyopathy (HOCM). However, in some cases, it is not easy to elucidate the abnormal structure of left ventricular outflow obstruction to adopt these treatments. Here, we presented a young female patient with drug‐refractory symptomatic HOCM. In this case, contrast‐enhanced computed tomography enabled us to assess the suitability of percutaneous transluminal septal myocardial ablation. By creating three‐dimensional printed models using computed tomography data, we could also visualize intracardiac structure and simulate the surgical procedure. A multimodality assessment strategy is useful for evaluating patients complicated with drug‐refractory symptomatic HOCM. PMID:29154429

  16. Catheter-induced dissection of the left main coronary artery, the nemesis of an invasive cardiologist A case report and review of the literature.

    PubMed

    Jain, Deepak; Kurowski, Volkhard; Katus, Hugo A; Richardt, Gert

    2002-10-01

    An elderly gentleman had a dissection of the left main coronary artery (LMCA) during coronary angiography. There were critical lesions in the left anterior descending (LAD) and left circumflex arteries. Both the LMCA and the LAD lesions were successfully stented in the same sitting. Thereafter the patient remained symptom free and the six-month follow-up angiogram revealed good angioplasty results in both lesions. We report this case for two reasons - first, acute dissection of the LMCA is a rare but devastating complication of selective coronary angiography and the situation becomes graver if the branch vessels have critical stenosis; that this could be managed percutaneously needs to be highlighted, and second, the case offers an opportunity to review literature pertinent to this awesome occurrence in the catheterization laboratory.

  17. Hybrid coronary revascularization in the era of drug-eluting stents.

    PubMed

    Murphy, Gavin J; Bryan, Alan J; Angelini, Gianni D

    2004-11-01

    Left internal mammary artery to left anterior descending coronary artery bypass grafting integrated with percutaneous coronary angioplasty (hybrid procedure) offers multivessel revascularization with minimal morbidity in high-risk patients. This is caused in part by the avoidance of cardiopulmonary bypass-related morbidity and manipulation of the aorta coupled with minimally invasive techniques. Hybrid revascularization is currently reserved for particularly high-risk patients or those with favorable anatomic variants however, largely because of the emergence of off-pump coronary artery bypass grafting, which permits more complete multivessel revascularization, with low morbidity in high-risk groups. The wider introduction of hybrid revascularization is limited chiefly by the high number of repeat interventions compared with off-pump coronary artery bypass grafting, which occurs because of the target vessel failure rate of percutaneous coronary intervention. Other demerits are the costs and logistic problems associated with performing two procedures with differing periprocedural management protocols. Recently, drug-eluting stents have reduced the need for repeat intervention after percutaneous coronary intervention, and this has raised the possibility that the results of hybrid revascularization may now equal or even better those of off-pump coronary artery bypass grafting. Although undoubtedly effective at reducing in-stent restenosis, drug-eluting stents will not address the issues of incomplete revascularization or the logistic problems associated with hybrid. Uncertainty regarding the long-term effectiveness of drug-eluting stents in many patients, as well as their high cost when compared with those of off-pump coronary artery bypass grafting surgery, also militates against the wider introduction of hybrid revascularization.

  18. Percutaneous closure of atrial septal defects leads to normalisation of atrial and ventricular volumes

    PubMed Central

    Teo, Karen SL; Dundon, Benjamin K; Molaee, Payman; Williams, Kerry F; Carbone, Angelo; Brown, Michael A; Worthley, Matthew I; Disney, Patrick J; Sanders, Prashanthan; Worthley, Stephen G

    2008-01-01

    Background Percutaneous closure of atrial septal defects (ASDs) should potentially reduce right heart volumes by removing left-to-right shunting. Due to ventricular interdependence, this may be associated with impaired left ventricular filling and potentially function. Furthermore, atrial changes post-ASD closure have been poorly understood and may be important for understanding risk of atrial arrhythmia post-ASD closure. Cardiovascular magnetic resonance (CMR) is an accurate and reproducible imaging modality for the assessment of cardiac function and volumes. We assessed cardiac volumes pre- and post-percutaneous ASD closure using CMR. Methods Consecutive patients (n = 23) underwent CMR pre- and 6 months post-ASD closure. Steady state free precession cine CMR was performed using contiguous slices in both short and long axis views through the ASD. Data was collected for assessment of left and right atrial, ventricular end diastolic volumes (EDV) and end systolic volumes (ESV). Data is presented as mean ± SD, volumes as mL, and paired t-testing performed between groups. Statistical significance was taken as p < 0.05. Results There was a significant reduction in right ventricular volumes at 6 months post-ASD closure (RVEDV: 208.7 ± 76.7 vs. 140.6 ± 60.4 mL, p < 0.0001) and RVEF was significantly increased (RVEF 35.5 ± 15.5 vs. 42.0 ± 15.2%, p = 0.025). There was a significant increase in the left ventricular volumes (LVEDV 84.8 ± 32.3 vs. 106.3 ± 38.1 mL, p = 0.003 and LVESV 37.4 ± 20.9 vs. 46.8 ± 18.5 mL, p = 0.016). However, there was no significant difference in LVEF and LV mass post-ASD closure. There was a significant reduction in right atrial volumes at 6 months post-ASD closure (pre-closure 110.5 ± 55.7 vs. post-closure 90.7 ± 69.3 mL, p = 0.019). Although there was a trend to a decrease in left atrial volumes post-ASD closure, this was not statistically significant (84.5 ± 34.8 mL to 81.8 ± 44.2 mL, p = NS). Conclusion ASD closure leads to normalisation of ventricular volumes and also a reduction in right atrial volume. Further follow-up is required to assess how this predicts outcomes such as risk of atrial arrhythmias after such procedures. PMID:19040763

  19. Components of the ALSEP deployed during Apollo 14 first EVA

    NASA Image and Video Library

    1971-02-05

    AS14-67-9376 (5 Feb. 1971) --- Several components of the Apollo lunar surface experiments package (ASLEP) are deployed in this photograph taken during the first Apollo 14 extravehicular activity (EVA). The larger object with antenna is the ALSEP central station (CS). The active seismic experiment (ASE) mortar package assembly is to the rear left of the CS. The charged particle lunar environment experiment (CPLEE) is to the right rear of the CS. A portion of the modularized equipment transporter (MET) can be seen in the left foreground.

  20. Predictors of transient left ventricular dysfunction following transcatheter patent ductus arteriosus closure in pediatric age.

    PubMed

    Agha, Hala Mounir; Hamza, Hala S; Kotby, Alyaa; Ganzoury, Mona E L; Soliman, Nanies

    2017-10-01

    To evaluate the left ventricular function before and after transcatheter percutaneous patent ductus arteriosus (PDA) closure, and to identify the predictors of myocardial dysfunction post-PDA closure if present. Transcatheter PDA closure; conventional, Doppler, and tissue Doppler imaging; and speckle tracking echocardiography. To determine the feasibility and reliability of tissue Doppler and myocardial deformation imaging for evaluating myocardial function in children undergoing transcatheter PDA closure. Forty-two children diagnosed with hemodynamically significant PDA underwent percutaneous PDA closure. Conventional, Doppler, and tissue Doppler imaging, and speckle-derived strain rate echocardiography were performed at preclosure and at 48 hours, 1 month, and 6 months postclosure. Tissue Doppler velocities of the lateral and septal mitral valve annuli were obtained. Global and regional longitudinal peak systolic strain values were determined using two-dimensional speckle tracking echocardiography. The median age of the patients was 2 years and body weight was 15 kg, with the mean PDA diameter of 3.11 ± 0.99 mm. M-mode measurements (left ventricular end diastolic diameter, left atrium diameter to aortic annulus ratio, ejection fraction, and shortening fraction) reduced significantly early after PDA closure ( p  < 0.001). After 1 month, left ventricular end diastolic diameter and left atrium diameter to aortic annulus ratio continued to decrease, while ejection fraction and fractional shortening improved significantly. All tissue Doppler velocities showed a significant decrease at 48 hours with significant prolongation of global myocardial function ( p  < 0.001) and then were normalized within 1 month postclosure. Similarly, global longitudinal strain significantly decreased at 48 hours postclosure ( p  < 0.001), which also recovered at 1 month follow-up. Preclosure global longitudinal strain showed a good correlation with the postclosure prolongation of the myocardial performance index. Transcatheter PDA closure causes a significant decrease in left ventricular performance early after PDA closure, which recovers completely within 1 month. Preclosure global longitudinal strain can be a predictor of postclosure myocardial dysfunction.

  1. Occlusion of a Long-Term Transpleural Biliary Drainage Tract Using a Gelatin Pledget (Hep-Plug™).

    PubMed

    Kortes, Nikolas; Gnutzmann, Daniel; Konietzke, Philip; Mayer, Philipp; Sumkauskaite, Migle; Kauczor, Hans-Ulrich; Radeleff, Boris A

    2017-11-01

    This case describes a technique used to close a long-term 14F transpleural biliary drainage catheter tract to prevent biliopleural fistula and further complications. We deployed a compressed gelatin foam pledget provided in a pre-loaded delivery device (Hep-Plug™) along the intrahepatic tissue tract for sealing it against the pleural cavity. The device used is easy to handle and gives the Interventional Radiologist the possibility to safely manage and prevent complications after percutaneous transhepatic interventions.

  2. Drug-eluting versus bare-metal stents in unprotected left main coronary artery stenosis a meta-analysis.

    PubMed

    Pandya, Sanjay B; Kim, Young-Hak; Meyers, Sheridan N; Davidson, Charles J; Flaherty, James D; Park, Duk-Woo; Mediratta, Anuj; Pieper, Karen; Reyes, Eric; Bonow, Robert O; Park, Seung-Jung; Beohar, Nirat

    2010-06-01

    We undertook a meta-analysis to assess outcomes for drug-eluting stents (DES) and bare-metal stents (BMS) in percutaneous coronary intervention for unprotected left main coronary artery (ULMCA) stenosis. Uncertainty exists regarding the relative performance of DES versus BMS in percutaneous coronary intervention for unprotected left main coronary stenosis. Of a total of 838 studies, 44 met inclusion criteria (n = 10,342). The co-primary end points were mortality, myocardial infarction (MI), target vessel/lesion revascularization (TVR/TLR), and major adverse cardiac events (MACE: mortality, MI, TVR/TLR). Event rates for DES and BMS were calculated at 6 to 12 months, at 2 years, and at 3 years. Crude event rates at 3 years were mortality (8.8% and 12.7%), MI (4.0% and 3.4%), TVR/TLR (8.0% and 16.4%), and MACE (21.4% and 31.6%). Nine studies were included in a comparative analysis (n = 5,081). At 6 to 12 months the adjusted odds ratio (OR) for DES versus BMS were: mortality 0.94 (95% confidence interval [CI]: 0.06 to 15.48; p = 0.97), MI 0.64 (95% CI: 0.19 to 2.17; p = 0.47), TVR/TLR 0.10 (95% CI: 0.01 to 0.84; p = 0.01), and MACE 0.34 (95% CI: 0.15 to 0.78; p = 0.01). At 2 years, the OR for DES versus BMS were: mortality 0.42 (95% CI: 0.28 to 0.62; p < 0.01), MI 0.16 (95% CI: 0.01 to 3.53; p = 0.13), and MACE 0.31 (95% CI: 0.15 to 0.66; p < 0.01). At 3 years, the OR for DES versus BMS were: mortality 0.70 (95% CI: 0.53 to 0.92; p = 0.01), MI 0.49 (95% CI: 0.26 to 0.92; p = 0.03), TVR/TLR 0.46 (95% CI: 0.30 to 0.69; p < 0.01), and MACE 0.78 (95% CI: 0.57 to 1.07; p = 0.12). Our meta-analysis suggests that DES is associated with favorable outcomes for mortality, MI, TVR/TLR, and MACE as compared to BMS in percutaneous coronary intervention for unprotected left main coronary artery stenosis. Copyright 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  3. Fragmented QRS complex is a prognostic marker of microvascular reperfusion and changes in LV function occur in patients with ST elevation myocardial infarction who underwent primary percutaneous coronary intervention.

    PubMed

    Zhang, Ruoxi; Chen, Shuyuan; Zhao, Qi; Sun, Meng; Yu, Bo; Hou, Jingbo

    2017-06-01

    The present study aimed to investigate the in-hospital and long-term prognostic value of fragmented QRS complex (fQRS) for microvascular reperfusion and changes in left ventricular (LV) function in patients with ST elevation myocardial infarction (STEMI) who underwent primary percutaneous coronary intervention (PCI). A total of 216 patients with STEMI undergoing primary PCI were included in the current study. Patients were divided into two groups based on the presence (n=126) or absence (n=90) of fQRS following electrocardiograms (ECGs) on admission. Following primary PCI and follow up, patients were divided into four groups based on new onset, resolution, persistence and absence of fQRS. Major adverse cardiac events were defined to include cardiovascular death, arrhythmia, heart failure, reinfarction and target vessel revascularization. The percentage of patients with heart failure and microvascular reperfusion differed significantly between the fQRS(+) and fQRS(-) groups. Levels of N-terminal pro-brain natriuretic peptide (NT-proBNP), Peak creatine kinase-MB (CK-MB) and Troponin I levels were observed to be significantly higher in the fQRS(+) group compared with the fQRS(-) group. In univariate logistic regression analysis, left ventricular ejection fraction (LVEF), NT-proBNP, Troponin I, Peak CK-MB and microvascular reperfusion were found to be associated with fQRS. Multivariate analysis identified that LVEF, NT-proBNP, Troponin I and microvascular reperfusion may be independent predictors of fQRS. The presence of fQRS was demonstrated to be associated with left ventricular dysfunction at follow up assessments. The presence of fQRS was not only significantly associated with myocardial microvascular reperfusion and left ventricular function, but was also a prognostic marker in STEMI.

  4. Randomized comparison of operator radiation exposure comparing transradial and transfemoral approach for percutaneous coronary procedures: rationale and design of the minimizing adverse haemorrhagic events by TRansradial access site and systemic implementation of angioX - RAdiation Dose study (RAD-MATRIX).

    PubMed

    Sciahbasi, Alessandro; Calabrò, Paolo; Sarandrea, Alessandro; Rigattieri, Stefano; Tomassini, Francesco; Sardella, Gennaro; Zavalloni, Dennis; Cortese, Bernardo; Limbruno, Ugo; Tebaldi, Matteo; Gagnor, Andrea; Rubartelli, Paolo; Zingarelli, Antonio; Valgimigli, Marco

    2014-06-01

    Radiation absorbed by interventional cardiologists is a frequently under-evaluated important issue. Aim is to compare radiation dose absorbed by interventional cardiologists during percutaneous coronary procedures for acute coronary syndromes comparing transradial and transfemoral access. The randomized multicentre MATRIX (Minimizing Adverse Haemorrhagic Events by TRansradial Access Site and Systemic Implementation of angioX) trial has been designed to compare the clinical outcome of patients with acute coronary syndromes treated invasively according to the access site (transfemoral vs. transradial) and to the anticoagulant therapy (bivalirudin vs. heparin). Selected experienced interventional cardiologists involved in this study have been equipped with dedicated thermoluminescent dosimeters to evaluate the radiation dose absorbed during transfemoral or right transradial or left transradial access. For each access we evaluate the radiation dose absorbed at wrist, at thorax and at eye level. Consequently the operator is equipped with three sets (transfemoral, right transradial or left transradial access) of three different dosimeters (wrist, thorax and eye dosimeter). Primary end-point of the study is the procedural radiation dose absorbed by operators at thorax. An important secondary end-point is the procedural radiation dose absorbed by operators comparing the right or left radial approach. Patient randomization is performed according to the MATRIX protocol for the femoral or radial approach. A further randomization for the radial approach is performed to compare right and left transradial access. The RAD-MATRIX study will probably consent to clarify the radiation issue for interventional cardiologist comparing transradial and transfemoral access in the setting of acute coronary syndromes. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Influence of the tilt angle of Percutaneous Aortic Prosthesis on Velocity and Shear Stress Fields

    PubMed Central

    Gomes, Bruno Alvares de Azevedo; Camargo, Gabriel Cordeiro; dos Santos, Jorge Roberto Lopes; Azevedo, Luis Fernando Alzuguir; Nieckele, Ângela Ourivio; Siqueira-Filho, Aristarco Gonçalves; de Oliveira, Glaucia Maria Moraes

    2017-01-01

    Background Due to the nature of the percutaneous prosthesis deployment process, a variation in its final position is expected. Prosthetic valve placement will define the spatial location of its effective orifice in relation to the aortic annulus. The blood flow pattern in the ascending aorta is related to the aortic remodeling process, and depends on the spatial location of the effective orifice. The hemodynamic effect of small variations in the angle of inclination of the effective orifice has not been studied in detail. Objective To implement an in vitro simulation to characterize the hydrodynamic blood flow pattern associated with small variations in the effective orifice inclination. Methods A three-dimensional aortic phantom was constructed, reproducing the anatomy of one patient submitted to percutaneous aortic valve implantation. Flow analysis was performed by use of the Particle Image Velocimetry technique. The flow pattern in the ascending aorta was characterized for six flow rate levels. In addition, six angles of inclination of the effective orifice were assessed. Results The effective orifice at the -4º and -2º angles directed the main flow towards the anterior wall of the aortic model, inducing asymmetric and high shear stress in that region. However, the effective orifice at the +3º and +5º angles mimics the physiological pattern, centralizing the main flow and promoting a symmetric distribution of shear stress. Conclusion The measurements performed suggest that small changes in the angle of inclination of the percutaneous prosthesis aid in the generation of a physiological hemodynamic pattern, and can contribute to reduce aortic remodeling. PMID:28793046

  6. Successful surgical treatment of left atrioesophageal fistula following atrial ablation.

    PubMed

    Takahashi, Toru; Mohara, Jun; Ogawa, Hiroomi; Igarashi, Takamichi; Motegi, Yoko

    2018-01-23

    A 69-year-old male had catheter-based ablation for atrial fibrillation. He was admitted with high fever and had neurological disorder; he was diagnosed with atrioesophageal fistula by CT scan. Intraoperative findings showed that the fistula existed adjacent to the left lower pulmonary vein with a vegetation. The esophageal fistula was repaired, and the left atrial fistula was closed. A nasogastric tube tip was placed in the esophagus for decompression and advanced into the stomach for nutritional support. After vomiting, the patient showed loss of consciousness and left hemiplegia. CT scan revealed a micro-air embolism to the brain. The nasogastric tube tip was pulled back into the esophagus. Gastrointestinal fiberscopy showed a pinhole at the fistula, and a percutaneous endoscopic gastrostomy was made. After conservative treatment, the esophageal fistula was closed and mediastinitis was improved. He was discharged with a little neurological deficit.

  7. Percutaneous Radiofrequency Ablation for Treatment of Recurrent Retroperitoneal Liposarcoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keil, Sebastian, E-mail: keil@rad.rwth-aachen.de; Bruners, Philipp; Brehmer, Bernhard

    2008-07-15

    Percutaneous CT-guided radiofrequency ablation (RFA) is becoming more and more established in the treatment of various neoplasms, including retroperitoneal tumors of the kidneys and the adrenal glands. We report the case of RFA in a patient suffering from the third relapse of a retroperitoneal liposarcoma in the left psoas muscle. After repeated surgical resection and supportive radiation therapy of a primary retroperitoneal liposarcoma and two surgically treated recurrences, including replacement of the ureter by a fraction of the ileum, there was no option for further surgery. Thus, we considered RFA as the most suitable treatment option. Monopolar RFA was performedmore » in a single session with a 2-cm umbrella-shaped LeVeen probe. During a 27-month follow-up period the patient remained free of tumor.« less

  8. Advances in percutaneous interventional therapies: the tricuspid valve.

    PubMed

    Jabbour, Richard J; Giannini, Francesco; Tanaka, Akihito; Mangieri, Antonio; Mikhail, Ghada W; Latib, Azeem; Colombo, Antonio

    2017-05-01

    Tricuspid regurgitation (TR) is a prevalent valve condition, with an estimated 1.6 million people in the USA living with moderate or greater severity. Functional TR, which predominantly develops due to left-sided heart disease, is the predominant condition affecting the tricuspid valve in the Western world and severe TR is associated with substantial morbidity and mortality. In part, due to a prolonged latency period with insidious symptoms, patients are often referred for surgery at advanced stages, with associated increased or prohibitive surgical risk. In addition, surgical treatment can result in high rates of recurrence. Therefore, there is an unmet need for percutaneous therapies that may provide a relatively low-risk treatment option. There are several devices with early human feasibility data available that will be reviewed in this article.

  9. Effect of transcatheter aortic valve implantation on intraoperative left ventricular end-diastolic pressure.

    PubMed

    Toyota, Kosaku; Ota, Takashi; Nagamine, Katsutoshi; Koide, Yasuhiro; Nomura, Takeshi; Yamanaka, Futoshi; Shishido, Koki; Tanaka, Masashi; Saito, Shigeru

    2016-12-01

    Transcatheter aortic valve implantation (TAVI) for patients with aortic stenosis is a less invasive alternative to surgical aortic valve replacement. Despite this, careful anesthetic management, especially strict control of blood pressure and fluid management, is necessary. During TAVI, normalization of left ventricular afterload due to aortic balloon valvuloplasty and prosthetic valve deployment is expected to result in rapid improvement of systolic function and consequent improvement in diastolic function. However, the early effect of TAVI on left ventricular diastolic function is less clear. We hypothesized that TAVI induces a rapid decrease in left ventricular end-diastolic pressure (LVEDP) after valve deployment. This retrospective observational study included 71 patients who had undergone TAVI using the transfemoral approach with a balloon-expandable valve under general anesthesia. Intraoperative LVEDP was measured using an intracardiac catheter. The severity of residual aortic regurgitation (AR) was assessed using the Sellers criteria. The mean (SD) LVEDP was 17.8 (5.3) mmHg just before TAVI and increased significantly to 27.3 (8.2) mmHg immediately after prosthetic valve deployment (p < 0.0001). The change in LVEDP was 8.7 (8.6) mmHg in patients with low residual AR (Sellers ≤1) and 11.0 (7.1) mmHg in those with high residual AR (Sellers ≥2); however, this difference was not significant. No correlation was found between the LVEDP change and intraoperative fluid balance. In conclusion, LVEDP increased significantly in the early period after valve deployment during TAVI, regardless of residual AR severity. It was suggested that the tolerability of fluid load could be reduced at that time.

  10. Percutaneous Transhepatic Portography for the Treatment of Early Portal Vein Thrombosis After Surgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adani, Gian Luigi, E-mail: adanigl@hotmail.com; Baccarani, Umberto; Risaliti, Andrea

    2007-11-15

    We treated three cases of early portal vein thrombosis (PVT) by minimally invasive percutaneous transhepatic portography. All patients developed PVT within 30 days of major hepatic surgery (one case each of orthotopic liver transplantation, splenectomy in a previous liver transplant recipient, and right extended hepatectomy with resection and reconstruction of the left branch of the portal vein for tumor infiltration). In all cases minimally invasive percutaneous transhepatic portography was adopted to treat this complication by mechanical fragmentation and pharmacological lysis of the thrombus. A vascular stent was also positioned in the two cases in which the thrombosis was related tomore » a surgical technical problem. Mechanical fragmentation of the thrombus with contemporaneous local urokinase administration resulted in complete removal of the clot and allowed restoration of normal blood flow to the liver after a median follow-up of 37 months. PVT is an uncommon but severe complication after major surgery or liver transplantation. Surgical thrombectomy, with or without reconstruction of the portal vein, and retransplantation are characterized by important surgical morbidity and mortality. Based on our experience, minimally invasive percutaneous transhepatic portography should be considered an option toward successful recanalization of early PVT after major liver surgery including transplantation. Balloon dilatation and placement of a vascular stent could help to decrease the risk of recurrent thrombosis when a defective surgical technique is the reason for the thrombosis.« less

  11. Early risk of mortality after coronary artery revascularization in patients with left ventricular dysfunction and potential role of the wearable cardioverter defibrillator.

    PubMed

    Zishiri, Edwin T; Williams, Sarah; Cronin, Edmond M; Blackstone, Eugene H; Ellis, Stephen G; Roselli, Eric E; Smedira, Nicholas G; Gillinov, A Marc; Glad, Jo Ann; Tchou, Patrick J; Szymkiewicz, Steven J; Chung, Mina K

    2013-02-01

    Implantation of implantable cardioverter defibrillator for prevention of sudden cardiac death is deferred for 90 days after coronary revascularization, but mortality may be highest early after cardiac procedures in patients with ventricular dysfunction. We determined mortality risk in postrevascularization patients with left ventricular ejection fraction ≤35% and compared survival with those discharged with a wearable cardioverter defibrillator (WCD). Hospital survivors after surgical (coronary artery bypass graft surgery) or percutaneous (percutaneous coronary intervention [PCI]) revascularization with left ventricular ejection fraction ≤35% were included from Cleveland Clinic and national WCD registries. Kaplan-Meier, Cox proportional hazards, propensity score-matched survival, and hazard function analyses were performed. Early mortality hazard was higher among 4149 patients discharged without a defibrillator compared with 809 with WCDs (90-day mortality post-coronary artery bypass graft surgery 7% versus 3%, P=0.03; post-PCI 10% versus 2%, P<0.0001). WCD use was associated with adjusted lower risks of long-term mortality in the total cohort (39%, P<0.0001) and both post-coronary artery bypass graft surgery (38%, P=0.048) and post-PCI (57%, P<0.0001) cohorts (mean follow-up, 3.2 years). In propensity-matched analyses, WCD use remained associated with lower mortality (58% post-coronary artery bypass graft surgery, P=0.002; 67% post-PCI, P<0.0001). Mortality differences were not attributable solely to therapies for ventricular arrhythmia. Only 1.3% of the WCD group had a documented appropriate therapy. Patients with left ventricular ejection fraction ≤35% have higher early compared to late mortality after coronary revascularization, particularly after PCI. As early hazard seemed less marked in WCD users, prospective studies in this high-risk population are indicated to confirm whether WCD use as a bridge to left ventricular ejection fraction improvement or implantable cardioverter defibrillator implantation can improve outcomes after coronary revascularization.

  12. The effect of transient balloon occlusion of the mitral valve on left atrial appendage blood flow velocity and spontaneous echo contrast.

    PubMed

    Wang, J; Chung Ann Choo, D; Zhang, X; Yang, Q; Xian, T; Lu, D; Jiang, S

    2000-07-01

    Spontaneous echo contrast (SEC) is a phenomenon that is commonly seen in areas of blood stasis. It is a slowly moving, cloud-like swirling pattern of "smoke" or increased echogenicity recorded on echocardiography. SEC is commonly seen in the left atrium of patients with mitral stenosis or atrial fibrillation. The presence of SEC has been shown to be a marker of increased thromboembolic risk. By using transesophageal echocardiography during percutaneous balloon mitral valvotomy (PBMV), the study investigated the relationship between SEC and varying left atrial appendage (LAA) blood flow velocity in the human heart. Thirty-five patients with rheumatic mitral stenosis underwent percutaneous balloon mitral valvotomy with intraoperative transesophageal echocardiography monitoring. We alternatively measured LAA velocities and observed the left atrium for various grades of SEC (0 = none to 4 = severe) before and after each balloon inflation. Left atrial appendage maximal ejection velocity was reduced from 35 +/- 14 to 6 +/- 2 mm/s at peak balloon inflation and increased to 40 +/- 16 mm/s after balloon deflation. In comparison with the values before balloon inflation and after balloon deflation, LAA velocities were significantly lower (p < 0.001). New or increased SEC grade was observed during 54 of 61 (88%) inflations and unchanged in 7 (12%) inflations at peak balloon inflation. Spontaneous echo contrast became lower in grade after 55 balloon deflations (90%), completely disappeared after 18 deflations (30%), and remained unchanged after 6 deflations (10%). The mean time to achieve maximal SEC grade (2.5 +/- 1.2 s) coincided with the mean time to trough LAA velocities (2.3 +/- 1.1 s) after balloon inflation. Upon deflation, the mean time to lowest SEC grade (2.9 +/- 1.8 s) coincided with mean time to achieve maximal LAA velocities (2.7 +/- 1.6 s). During balloon inflation, the severity of SEC was enhanced with corresponding reduction in LAA flow velocity. Upon balloon deflation, SEC lightens or disappears with increase in LAA flow velocity.

  13. Percutaneous ligation of the left atrial appendage results in atrial electrical substrate modification.

    PubMed

    Syed, Faisal F; Rangu, Venu; Bruce, Charles J; Johnson, Susan B; Danielsen, Andrew; Gilles, Emily J; Ladewig, Dorothy J; Mikell, Susan B; Berhow, Steven; Wahnschaffe, Douglas; Suddendorf, Scott H; Asirvatham, Samuel J; Friedman, Paul A

    2015-03-01

    Debulking of electrically active atrial tissue may reduce the mass of fibrillating tissue during atrial fibrillation, eliminate triggers, and promote maintenance of normal sinus rhythm (NSR). We investigated whether left atrial appendage (LAA) ligation results in modification of atrial electrical substrate. Healthy male mongrel dogs (N = 20) underwent percutaneous epicardial LAA ligation. The ligation system grabber recorded LAA local electrograms (EGM) continuously before, during, and after closure. Successful ligation with a preloaded looped suture was confirmed intraprocedurally by LAA Doppler flow cessation on transesophageal echocardiography (TEE) and loss of LAA electrical activity, and after procedure by direct necropsic visualization. P-wave duration on surface electrocardiograms was measured immediately before and after LAA closure. Percent P-wave duration reduction was correlated with preclosure LAA internal dimensions measured by TEE and external dimensions measured on necropsy specimens to investigate associations of LAA geometry with the extent of electrical substrate modification. LAA ligation was successful in all dogs and accompanied by loss of LAA EGM. P-wave duration reduced immediately on ligation (mean 75 ms preligation to 63 ms postligation; mean difference ± standard error, 12 ± 1 ms; P < 0.0001). Percent P-wave reduction was associated with larger LAA longitudinal cross-sectional area (R(2) = 0.263, P = 0.04) and smaller external circumference (R(2) = 0.687, P = 0.04). All dogs were in sinus rhythm. Percutaneous LAA ligation results in its acute electrical isolation and atrial electrical substrate modification, the degree of which is associated with LAA geometry. These electrical changes raise the possibility that LAA ligation may promote NSR by removing LAA substrate and triggers. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Transcranial Doppler quantification of residual shunt after percutaneous patent foramen ovale closure: correlation of device efficacy with intracardiac anatomic measures.

    PubMed

    Sorensen, Sherman G; Spruance, Spotswood L; Smout, Randall; Horn, Susan

    2012-06-01

    Percutaneous, mechanical closure of defects of the atrial septum fails to completely resolve shunting in up to 20% of cases. Little is known about the factors associated with device failure. We measured the left atrial opening (X), right atrial opening (Z), tunnel length (Y), septum secundum, device-septum primum separation, and tunnel compressibility of the patent foramen ovale (PFO) in 301 patients with cryptogenic neurological events, PFO anatomy, and severe Valsalva shunting (Spencer Grade 5-5+). All patients then underwent percutaneous closure with the GORE®HELEX Septal Occluder device and were evaluated at 3 months for residual shunt by transcranial Doppler (TCD). Severe residual Valsalva shunt (TCD Grade 5-5+) was found at 3 months in 21 of 301 (7%) patients. X, Y, and Z were associated with failure with a high degree of statistical significance, whereas the width of the septum secundum, device-septum primum separation, and tunnel compressibility were not. An unanticipated finding was that 14 of 35 (40%) patients sized with a large balloon failed compared with 9 of 280 (3%) sized with a small balloon (P < 0.0001). In the multivariate logistic regression model, X (P = < 0.0001) and balloon size (P < 0.0001) were both strong predictors of failure. In an intracardiac echocardiography-defined PFO population, characterized by severe baseline Valsalva shunt and a high incidence of persistent (rest) shunting, association of six intracardiac measurements to closure device failure by multivariate logistic regression showed that the width of the left atrial opening was a strong predictor of residual shunting. An unanticipated finding was that use of a large sizing balloon was also strongly associated with failure. ©2012, Wiley Periodicals, Inc.

  15. Percutaneous cystolithotripsy using self-retaining laparoscopic trocar for management of large bladder stones.

    PubMed

    Elbahnasy, Abdelhamid M; Farhat, Yasser A; Aboramadan, Ahmad R; Taha, Mohamed Rasheed

    2010-12-01

    Percutaneous endoscopic management of bladder stones is not new. The ideal technique to establish suprapubic access, however, is still not justified. In this study, we used the 12-mm self-retaining laparoscopic trocar for access during management of large bladder stones. With the patient in the lithotomy position, a 12-mm self-retaining laparoscopic trocar was inserted in a full bladder under cystoscopic visual control. A 28F nephroscope was used to fragment the stone using ultrasound and pneumoclast lithotriptors. After stone treatment, the trocar was left in place, and transurethral resection of the prostate (TURP) was completed when indicated. Both urethral and suprapubic catheters were left at the end of the procedure. Clinical examination, urinalysis, and ultrasonographic examination were routinely performed during follow-up visits. The mean stone size was 4.07 + 0.20 cm (2.8-6 cm). The average time for stone fragmentation was 32.78 + 2.16 minutes (range 8-53 min). A concomitant TURP was performed in 12 patients. The mean hospital stay was 2.56 + 0.15 days (range 1-4 days). All patients were stone free, and a total of six complications occurred, including extravasation, one patient; hematuria, two patients; and fever, three patients. All were treated conservatively. The mean follow-up time was 15.65 + 1.51 months (range 9-36 mos). Suprapubic percutaneous cystolithotripsy is a safe, minimally invasive alternative for management of large bladder stones. The use of a self-retaining trocar facilitates access and allows use of a large nephroscope for rapid fragmentation and extraction of the stone fragments. The presence of specific trocars for suprapubic access into the urinary bladder will encourage more transvesical end-laparoscopic procedures.

  16. Comparison of Immediate With Delayed Stenting Using the Minimalist Immediate Mechanical Intervention Approach in Acute ST-Segment-Elevation Myocardial Infarction: The MIMI Study.

    PubMed

    Belle, Loic; Motreff, Pascal; Mangin, Lionel; Rangé, Grégoire; Marcaggi, Xavier; Marie, Antoine; Ferrier, Nadine; Dubreuil, Olivier; Zemour, Gilles; Souteyrand, Géraud; Caussin, Christophe; Amabile, Nicolas; Isaaz, Karl; Dauphin, Raphael; Koning, René; Robin, Christophe; Faurie, Benjamin; Bonello, Laurent; Champin, Stanislas; Delhaye, Cédric; Cuilleret, François; Mewton, Nathan; Genty, Céline; Viallon, Magalie; Bosson, Jean Luc; Croisille, Pierre

    2016-03-01

    Delayed stent implantation after restoration of normal epicardial flow by a minimalist immediate mechanical intervention aims to decrease the rate of distal embolization and impaired myocardial reperfusion after percutaneous coronary intervention. We sought to confirm whether a delayed stenting (DS) approach (24-48 hours) improves myocardial reperfusion, versus immediate stenting, in patients with acute ST-segment-elevation myocardial infarction undergoing primary percutaneous coronary intervention. In the prospective, randomized, open-label minimalist immediate mechanical intervention (MIMI) trial, patients (n=140) with ST-segment-elevation myocardial infarction ≤12 hours were randomized to immediate stenting (n=73) or DS (n=67) after Thrombolysis In Myocardial Infarction 3 flow restoration by thrombus aspiration. Patients in the DS group underwent a second coronary arteriography for stent implantation a median of 36 hours (interquartile range 29-46) after randomization. The primary end point was microvascular obstruction (% left ventricular mass) on cardiac magnetic resonance imaging performed 5 days (interquartile range 4-6) after the first procedure. There was a nonsignificant trend toward lower microvascular obstruction in the immediate stenting group compared with DS group (1.88% versus 3.96%; P=0.051), which became significant after adjustment for the area at risk (P=0.049). Median infarct weight, left ventricular ejection fraction, and infarct size did not differ between groups. No difference in 6-month outcomes was apparent for the rate of major cardiovascular and cerebral events. The present findings do not support a strategy of DS versus immediate stenting in patients with ST-segment-elevation infarction undergoing primary percutaneous coronary intervention and even suggested a deleterious effect of DS on microvascular obstruction size. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01360242. © 2016 American Heart Association, Inc.

  17. Arteriolymphatic Fistula: An Unusual Cause of Spontaneous Swelling in the Left Supraclavicular Region

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karuppiah Viswanathan, Ashok Mithra, E-mail: ashokmithrakv@gmail.com; Irodi, Aparna; Keshava, Shyamkumar N., E-mail: aparna-shyam@yahoo.com

    2016-09-15

    An abnormal fistulous communication between an artery and lymphatic system is a rare occurrence. We report a 38-year-old male presenting with sudden onset, spontaneous, pulsatile swelling in the left supraclavicular region following a recent cardiac catheterisation via right femoral arterial access. On evaluation, he was found to have a femoral arteriolymphatic fistula. He was managed conservatively with ultrasound-guided compression with complete resolution of symptoms at follow-up. This case describes a hitherto unknown complication of percutaneous vascular cannulation presenting in an unusual manner, diagnosed with Doppler Ultrasonography and CT angiography and managed effectively with a non-invasive therapeutic image-guided manoeuvre.

  18. Developing a new hybrid revascularization program: a road map for hospital managers and physician leaders.

    PubMed

    Harjai, Kishore J; Samy, Sanjay; Pennypacker, Barbara; Onofre, Bonnie; Stanfield, Pamela; Yaeger, Lynne; Stapleton, Dwight; Esrig, Barry C

    2012-12-01

    Hybrid coronary revascularization, which involves minimally invasive direct coronary artery bypass surgery using the left internal mammary artery to left anterior descending and percutaneous coronary intervention using drug-eluting stents for the remaining diseased coronary vessels, is an innovative approach to decrease the morbidity of conventional surgery. Little information is available to guide hospital managers and physician leaders in implementing a hybrid revascularization program. In this article, we describe the people-process-technology issues that managers and leaders are likely to encounter as they develop a hybrid revascularization program in their practice. ©2012, Wiley Periodicals, Inc.

  19. Effect of supersaturated oxygen delivery on infarct size after percutaneous coronary intervention in acute myocardial infarction.

    PubMed

    Stone, Gregg W; Martin, Jack L; de Boer, Menko-Jan; Margheri, Massimo; Bramucci, Ezio; Blankenship, James C; Metzger, D Christopher; Gibbons, Raymond J; Lindsay, Barbara S; Weiner, Bonnie H; Lansky, Alexandra J; Krucoff, Mitchell W; Fahy, Martin; Boscardin, W John

    2009-10-01

    Myocardial salvage is often suboptimal after percutaneous coronary intervention in ST-segment elevation myocardial infarction. Posthoc subgroup analysis from a previous trial (AMIHOT I) suggested that intracoronary delivery of supersaturated oxygen (SSO(2)) may reduce infarct size in patients with large ST-segment elevation myocardial infarction treated early. A prospective, multicenter trial was performed in which 301 patients with anterior ST-segment elevation myocardial infarction undergoing percutaneous coronary intervention within 6 hours of symptom onset were randomized to a 90-minute intracoronary SSO(2) infusion in the left anterior descending artery infarct territory (n=222) or control (n=79). The primary efficacy measure was infarct size in the intention-to-treat population (powered for superiority), and the primary safety measure was composite major adverse cardiovascular events at 30 days in the intention-to-treat and per-protocol populations (powered for noninferiority), with Bayesian hierarchical modeling used to allow partial pooling of evidence from AMIHOT I. Among 281 randomized patients with tc-99m-sestamibi single-photon emission computed tomography data in AMIHOT II, median (interquartile range) infarct size was 26.5% (8.5%, 44%) with control compared with 20% (6%, 37%) after SSO(2). The pooled adjusted infarct size was 25% (7%, 42%) with control compared with 18.5% (3.5%, 34.5%) after SSO(2) (P(Wilcoxon)=0.02; Bayesian posterior probability of superiority, 96.9%). The Bayesian pooled 30-day mean (+/-SE) rates of major adverse cardiovascular events were 5.0+/-1.4% for control and 5.9+/-1.4% for SSO(2) by intention-to-treat, and 5.1+/-1.5% for control and 4.7+/-1.5% for SSO(2) by per-protocol analysis (posterior probability of noninferiority, 99.5% and 99.9%, respectively). Among patients with anterior ST-segment elevation myocardial infarction undergoing percutaneous coronary intervention within 6 hours of symptom onset, infusion of SSO(2) into the left anterior descending artery infarct territory results in a significant reduction in infarct size with noninferior rates of major adverse cardiovascular events at 30 days. Clinical Trial Registration- clinicaltrials.gov Identifier: NCT00175058.

  20. The Left Atrial Appendage Revised

    PubMed Central

    Evora, Paulo Roberto Barbosa; Menardi, Antonio Carlos; Celotto, Andrea Carla; Albuquerque, Agnes Afrodite S.; Chagas, Hannah Miranda Araujo; Rodrigues, Alfredo José

    2017-01-01

    Nonvalvular atrial fibrillation is associated with a 4- to 5-fold strokes increase and may be responsible for 15% to 20% of all strokes in the elderly. In this scenario, the left atrial appendage thrombus would be the associated with 90% of cases. The use of anticoagulants, percutaneous devices, and the left atrial appendage surgical exclusion is still an open discussion. For left atrial appendage procedures, relevant anatomic spatial relationships have to be emphasized, besides the chance of the normal physiological functioning would be eliminated with the proceedings. There are evidences that the left atrial appendage closure during routine cardiac surgery is significantly associated with an increased risk of early postoperative atrial fibrillation. Therefore, the purpose of this review is to focus basic aspects for continuous medical education. In summary, the rationale of this text is to emphasize anatomical and pharmacological aspects involved in the simple surgical exclusion of left atrial appendage under cardiopulmonary bypass. There are several operative techniques, but to conclude this revision it will present one of them based on the discussed basic sciences. PMID:29267615

  1. Three-year outcomes after percutaneous coronary intervention and coronary artery bypass grafting in patients with heart failure: from the CREDO-Kyoto percutaneous coronary intervention/coronary artery bypass graft registry cohort-2†.

    PubMed

    Marui, Akira; Kimura, Takeshi; Nishiwaki, Noboru; Komiya, Tatsuhiko; Hanyu, Michiya; Shiomi, Hiroki; Tanaka, Shiro; Sakata, Ryuzo

    2015-02-01

    Ischaemic heart disease is a major risk factor for heart failure. However, long-term benefit of percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG) in those patients has not been well elucidated. Of the 15 939 patients undergoing first myocardial revascularization enrolled in the CREDO-Kyoto PCI/CABG Registry Cohort-2, we identified 1064 patients with multivessel and/or left main disease with a history of heart failure (ACC/AHA Stage C or D). There were 672 patients undergoing PCI and 392 CABG. Preprocedural left ventricular ejection fraction was not different between PCI and CABG (46.6 ± 15.1 vs 46.6 ± 14.6%, P = 0.89), but the CABG group included more patients with triple-vessel and left main disease (P < 0.01 each). Three-year outcomes revealed that the risk of hospital readmission for heart failure was higher after PCI than after CABG (hazard ratio [95% confidence interval]; 1.90 [1.18-3.05], P = 0.01). More importantly, adjusted mortality after PCI was significantly higher than after CABG (1.79 [1.13-2.82], P = 0.01). The risk of cardiac death after PCI was also higher than after CABG (1.98 [1.10-3.55], P = 0.02). Stratified analysis using the SYNTAX score demonstrated that risk of death was not different between PCI and CABG in patients with low (<23) and intermediate (23-32) SYNTAX scores (2.10 [0.57-7.68], P = 0.26 and 1.43 [0.63-3.21], P = 0.39, respectively), whereas those with a high (≥ 33) SYNTAX score, the risk of death was far higher after PCI than after CABG (4.83 [1.46-16.0], P = 0.01). In patients with heart failure with advanced coronary artery disease, CABG was a better option than PCI because CABG was associated with better survival benefit, particularly in more complex coronary lesions stratified by the SYNTAX score. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  2. Manual Thrombus Aspiration and the Improved Survival of Patients With Unstable Angina Pectoris Treated With Percutaneous Coronary Intervention (30 Months Follow-Up).

    PubMed

    Yildiz, Bekir S; Bilgin, Murat; Zungur, Mustafa; Alihanoglu, Yusuf I; Kilic, Ismail D; Buber, Ipek; Ergin, Ahmet; Kaftan, Havane A; Evrengul, Harun

    2016-02-01

    The clinical effect of intracoronary thrombus aspiration during percutaneous coronary intervention in patients with unstable angina pectoris is unknown. In this study, we aimed to assess how thrombus aspiration during percutaneous coronary intervention affects in-hospital and 30-month mortality and complications in patients with unstable angina pectoris.We undertook an observational cohort study of 645 consecutive unstable angina pectoris patients who had performed percutaneous coronary intervention from February 2011 to March 2013. Before intervention, 159 patients who had culprit lesion with thrombus were randomly assigned to group 1 (thrombus aspiration group) and group 2 (stand-alone percutaneous coronary intervention group). All patients were followed-up 30 months until August 2015.Thrombus aspiration was performed in 64 patients (46%) whose cardiac markers (ie, creatinine kinase [CK-MB] mass and troponin T) were significantly lower after percutaneous coronary intervention than in those of group 2 (CK-MB mass: 3.80 ± 1.11 vs 4.23 ± 0.89, P = 0.012; troponin T: 0.012 ± 0.014 vs 0.018 ± 0.008, P = 0.002). Left ventricular ejection fraction at 6, 12, and 24 months postintervention was significantly higher in the group 1. During a mean follow-up period of 28.87 ± 6.28 months, mortality rates were 6.3% in the group 1 versus 12.9% in the group 2. Thrombus aspiration was also associated with significantly less long-term mortality in unstable angina pectoris patients (adjusted HR: 4.61, 95% CI: 1.16-18.21, P = 0.029).Thrombus aspiration in the context of unstable angina pectoris is associated with a limited elevation in cardiac enzymes during intervention that minimises microembolization and significantly improves both of epicardial flow and myocardial perfusion, as shown by angiographic TIMI flow grade and frame count. Thrombus aspiration during percutaneous coronary intervention in unstable angina pectoris patients has better survival over a 30-month follow-up period.

  3. Percutaneous Dilational Tracheotomy in Solid-Organ Transplant Recipients.

    PubMed

    Ozdemirkan, Aycan; Ersoy, Zeynep; Zeyneloglu, Pinar; Gedik, Ender; Pirat, Arash; Haberal, Mehmet

    2015-11-01

    Solid-organ transplant recipients may require percutaneous dilational tracheotomy because of prolonged mechanical ventilation or airway issues, but data regarding its safety and effectiveness in solid-organ transplant recipients are scarce. Here, we evaluated the safety, effectiveness, and benefits in terms of lung mechanics, complications, and patient comfort of percutaneous dilational tracheotomy in solid-organ transplant recipients. Medical records from 31 solid-organ transplant recipients (median age of 41.0 years [interquartile range, 18.0-53.0 y]) who underwent percutaneous dilational tracheotomy at our hospital between January 2010 and March 2015 were analyzed, including primary diagnosis, comorbidities, duration of orotracheal intubation and mechanical ventilation, length of intensive care unit and hospital stays, the time interval between transplant to percutaneous dilational tracheotomy, Acute Physiology and Chronic Health Evaluation II score, tracheotomy-related complications, and pulmonary compliance and ratio of partial pressure of arterial oxygen to fraction of inspired oxygen. The median Acute Physiology and Chronic Health Evaluation II score on admission was 24.0 (interquartile range, 18.0-29.0). The median interval from transplant to percutaneous dilational tracheotomy was 105.5 days (interquartile range, 13.0-2165.0 d). The only major complication noted was left-sided pneumothorax in 1 patient. There were no significant differences in ratio of partial pressure of arterial oxygen to fraction of inspired oxygen before and after procedure (170.0 [interquartile range, 102.2-302.0] vs 210.0 [interquartile range, 178.5-345.5]; P = .052). However, pulmonary compliance results preprocedure and postprocedure were significantly different (0.020 L/cm H2O [interquartile range, 0.015-0.030 L/cm H2O] vs 0.030 L/cm H2O [interquartile range, 0.020-0.041 L/cm H2O); P = .001]). Need for sedation significantly decreased after tracheotomy (from 17 patients [54.8%] to 8 patients [25.8%]; P = .004]). Percutaneous dilational tracheotomy with bronchoscopic guidance is an efficacious and safe technique for maintaining airways in solidorgan transplant recipients who require prolonged mechanical ventilation, resulting in possible improvements in ventilatory mechanics and patient comfort.

  4. Astronaut Alan Bean deploys Lunar Surface Magnetometer on lunar surface

    NASA Image and Video Library

    1969-11-19

    Astronaut Alan L. Bean, lunar module pilot, deploys the Lunar Surface Magnetometer (LSM) during the first Apollo 12 extravehicular activity on the Moon. The LSM is a component of the Apollo Lunar Surface Experiments Package (ALSEP). The Lunar Module can be seen in the left background.

  5. Astronaut Alan Bean deploys Lunar Surface Magnetometer on lunar surface

    NASA Technical Reports Server (NTRS)

    1969-01-01

    Astronaut Alan L. Bean, lunar module pilot, deploys the Lunar Surface Magnetometer (LSM) during the first Apollo 12 extravehicular activity on the Moon. The LSM is a component of the Apollo Lunar Surface Experiments Package (ALSEP). The Lunar Module can be seen in the left background.

  6. Role of ultrasonography in percutaneous renal access in patients with renal anatomic abnormalities.

    PubMed

    Penbegul, Necmettin; Hatipoglu, Namik Kemal; Bodakci, Mehmet Nuri; Atar, Murat; Bozkurt, Yasar; Sancaktutar, Ahmet Ali; Tepeler, Abdulkadir

    2013-05-01

    To present our experience regarding the feasibility, safety, and efficacy of ultrasound (US)-guided percutaneous nephrolithotomy in anatomically abnormal kidneys. We performed US-guided percutaneous nephrolithotomy in 15 patients with anatomically abnormal kidneys and renal calculi. Of the 15 patients, 5 had horseshoe kidneys, 5 had rotation anomalies, 2 had kyphoscoliosis, and 3 had scoliosis. The stone size, number of access tracts, operative time, hospitalization duration, rate of stone clearance, and complication rate were recorded. Percutaneous access was achieved with US guidance in the operating room by the urologist. Successful renal access was obtained by the surgeon using US guidance in all patients, and a single access was obtained in all cases. Of the 15 patients, 8 were females, and 7 were males; 8 patients had solitary stones, and 7 had multiple calculi. The renal calculi were on the right in 7 patients and on the left in 8. Three patients had previously undergone unsuccessful shock wave lithotripsy. Complete stone clearance was achieved in 13 patients. The mean operative time was 54.2 minutes. No patient required a blood transfusion because of bleeding. Urinary tract infections occurred in 2 patients, who were treated with antibiotics. A double-J catheter was not inserted in any patient; however, a ureteral catheter was used in 3 patients for 1 day. None of the patients had any major complications during the postoperative period. The stone-free rate was 87%, and 2 patients had clinically insignificant residual fragments. Our results have demonstrated that US-guided percutaneous nephrolithotomy can be performed feasibly, safely, and effectively in anatomically abnormal kidneys. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Diastolic function of the nonfilling human left ventricle.

    PubMed

    Paulus, W J; Vantrimpont, P J; Rousseau, M F

    1992-12-01

    To investigate an early-diastolic left ventricular suction effect in humans, tip-micromanometer left ventricular pressure recordings were obtained in patients with mitral stenosis at the time of balloon inflations during percutaneous mitral valvuloplasty performed with a self-positioning Inoue balloon, which fits tightly in the mitral orifice. When mitral inflow was impeded in anesthetized dogs, left ventricular pressure decayed to a negative asymptote value. This negative asymptote value was consistent with an early diastolic suction effect. Tip-micromanometer left ventricular pressure recordings were obtained in 23 patients with symptomatic mitral stenosis at the time of balloon inflations during percutaneous mitral valvuloplasty performed with a self-positioning Inoue balloon. The left ventricular diastolic asymptote pressure (P(asy)) was determined in 47 nonfilling beats with a sufficiently long (greater than 200 ms) diastolic time interval (that is, the interval from minimal first derivative of left ventricular pressure to left ventricular end-diastolic pressure) and equaled 2 +/- 3 mm Hg for beats with normal intraventricular conduction and 3 +/- 2 mm Hg for beats with aberrant intraventricular conduction. Left ventricular angiography was performed in five patients during the first inflation of the Inoue balloon at the time of complete balloon expansion. Left ventricular end-diastolic volume of the nonfilling beats averaged 38 +/- 14 ml and was comparable to the left ventricular end-systolic volume (39 +/- 19 ml) measured during baseline angiography before mitral valvuloplasty. Time constants of left ventricular pressure decay were calculated on 21 nonfilling beats with a diastolic time interval greater than 200 ms, normal intraventricular conduction and peak left ventricular pressure greater than 50 mm Hg. Time constants (T0 and TBF) derived from an exponential curve fit with zero asymptote pressure and with a best-fit asymptote pressure were compared with a time constant (T(asy)) derived from an exponential curve fit with the measured diastolic left ventricular asymptote pressure. The value for T(asy) (37 +/- 9 ms) was significantly smaller than that for TBF (68 +/- 28 ms, p less than 0.001) and the value for the measured diastolic left ventricular asymptote pressure (2 +/- 4 mm Hg) was significantly larger than that for the best-fit asymptote pressure (-9 +/- 11 mm Hg, p less than 0.001). T0 (44 +/- 20 ms) was significantly (p less than 0.01) different from TBF but not from T(asy). During balloon inflation of a self-positioning Inoue balloon, left ventricular pressure decayed continuously toward a positive asymptote value and left ventricular cavity volume was comparable to the left ventricular end-systolic volume of filling beats. In these nonfilling beats, the best-fit asymptote pressure was unrelated to the measured asymptote pressure and T0 was a better measure of T(asy) than was TBF. Reduced internal myocardial restoring forces, caused by different extracellular matrix of the human heart, reduced external myocardial restoring forces caused by low coronary perfusion pressure during the balloon inflation and inward motion of the balloon-occluded mitral valve into the left ventricular cavity could explain the failure to observe significant diastolic left ventricular suction in the human heart.

  8. Malignant biliary disease: percutaneous interventions.

    PubMed

    Morgan, R A; Adam, A N

    2001-09-01

    Interventional radiologists have an important role in the management of patients with malignant biliary obstruction. This article describes the techniques for percutaneous biliary drainage, insertion of biliary endoprostheses, and the management of occluded biliary endoprostheses. Most procedures are performed by using fluoroscopic guidance alone. Ultrasound is also a useful modality for guiding biliary drainage, particularly drainage of the left biliary ducts. Patients should be treated by internal drainage if possible. Metallic endoprostheses can be inserted at the time of the initial biliary drainage procedure. Plastic tubes should be inserted a few days after biliary drainage because of their relatively large size compared with metallic stents. Occluded plastic stents should be replaced. Blocked metallic stents should be treated either by placement of additional overlapping metallic stents or by placement of plastic stents within the metallic stent lumen. Copyright 2001 by W.B. Saunders Company

  9. Management of Retained Intervention Guide-wire: A Literature Review

    PubMed Central

    Al-Moghairi, Abdulrahman M; Al-Amri, Hussein S

    2013-01-01

    Percutaneous coronary angioplasty is increasingly employed in the treatment of patients with complex coronary artery disease. Different steerable guide wires used to open occluded vessel and facilitate balloon and stent deployment. However, the guide-wire itself is not without hazard: it may perforate or dissect the vessel, but fracture or entrapment is uncommon. Its management depends on the clinical situation of the patient, as well as the position and length of the remnant. In this review we discuss the angioplasty guide-wire fracture and entrapment risk factors, potential risks and management. PMID:23116055

  10. Spontaneous Retro-Orbital Subperiosteal Hemorrhage with Complete Resolution Following Percutaneous Coronary Intervention for Acute Myocardial Infarction.

    PubMed

    Wu, Hsu-Ping; Tsai, Chia-Jung; Tsai, Jui-Peng; Hung, Chung-Lieh; Kuo, Jen-Yuan; Hou, Charles Jia-Yin

    2013-03-01

    Among the several treatment strategies available for acute myocardial infarction, primary percutaneous coronary intervention concomitant with antithrombotic agents is the primary treatment used to facilitate coronary reperfusion. However, bleeding can create major complications. Here we have presented a case of acute myocardial infarction treated with reperfusion therapy, after which developed a sudden onset of proptosis, with high intraocular pressure, blurred vision, and ecchymosis of the left eye. Spontaneous retro-orbital subperiosteal hemorrhage, a rare complication, was diagnosed based on those symptoms as noted above, as well as other orbital signs and imaging evaluation. Multiple antithrombotic agents, including antiplatelets, low molecular weight heparin, and glycoprotein IIb/IIIa receptor inhibitor were thought to be the main precipitating factors of this complication. Thereafter, conservative medical treatment was applied. In the following 2 weeks, all the patient's orbital signs resolved gradually without visual impairment. In conclusion, our experience with a rare case of complications arising from reperfusion therapy used to treat myocardial infarction suggests that clinicians should remain vigilant for any hemorrhagic events during acute myocardial infarction treatment. Acute myocardial infarction; Percutaneous coronary intervention; Retro-orbital subperiosteal hemorrhage.

  11. Unilateral improvement in glomerular filtration rate after permanent drainage of a perinephric pseudocyst in a cat.

    PubMed

    McCord, Kelly; Steyn, Philip F; Lunn, Katharine F

    2008-07-01

    A 12-year-old, 6 kg, castrated male Siamese-cross cat was referred for investigation of an abdominal mass. The cat was found to have a left perinephric pseudocyst (PNP), accompanied by azotemia, with a small right kidney detected on ultrasound. Glomerular filtration rate (GFR) was determined by renal scintigraphy and was found to be low, with the left kidney contributing 64% of the total GFR. Percutaneous ultrasound-guided drainage of the PNP did not improve the GFR, and fluid reaccumulated within a short period of time. Laparoscopic fenestration of the cyst capsule was performed to allow for permanent drainage. The PNP did not recur, renal values progressively improved, and 8 months after the capsulotomy the GFR of the left kidney had increased by 50%, while renal function remained static on the right side.

  12. Percutaneous Epicardial Pacing using a Novel Insulated Multi-electrode Lead.

    PubMed

    Syed, Faisal F; DeSimone, Christopher V; Ebrille, Elisa; Gaba, Prakriti; Ladewig, Dorothy J; Mikell, Susan B; Suddendorf, Scott H; Gilles, Emily J; Danielsen, Andrew J; Lukášová, Markéta; Wolf, Jiří; Leinveber, Pavel; Novák, Miroslav; Stárek, Zdeněk; Kara, Tomas; Bruce, Charles J; Friedman, Paul A; Asirvatham, Samuel J

    2015-08-01

    Epicardial cardiac resynchronization therapy (CRT) permits unrestricted electrode positioning. However, this requires surgical placement of device leads and the risk of unwanted phrenic nerve stimulation. We hypothesized that shielded electrodes can capture myocardium without extracardiac stimulation. In 6 dog and 5 swine experiments, we used a percutaneous approach to access the epicardial surface of the heart, and deploy novel leads housing multiple electrodes with selective insulation. Bipolar pacing thresholds at prespecified sites were tested compare electrode threshold data both facing towards and away from the epicardial surface. In 151 paired electrode recordings (70 in 6 dogs; 81 in 5 swine), thresholds facing myocardium were lower than facing away (median [IQR] mA: dogs 0.9 [0.4-1.6] vs 4.6 [2.1 to >10], p<0.0001; swine 0.5 [0.2-1] vs 2.5 [0.5-6.8], p<0.0001). Myocardial capture was feasible without extracardiac stimulation at all tested sites, with mean ± SE threshold margin 3.6±0.7 mA at sites of high output extracardiac stimulation (p=0.004). Selective electrode insulation confers directional pacing to a multielectrode epicardial pacing lead. This device has the potential for a novel percutaneous epicardial resynchronization therapy that permits placement at an optimal pacing site, irrespective of the anatomy of the coronary veins or phrenic nerves.

  13. Arterial stiffness as a predictor of recovery of left ventricular systolic function after acute myocardial infarction treated with primary percutaneous coronary intervention.

    PubMed

    Imbalzano, Egidio; Vatrano, Marco; Mandraffino, Giuseppe; Ghiadoni, Lorenzo; Gangemi, Sebastiano; Bruno, Rosa Maria; Ciconte, Vincenzo Antonio; Paunovic, Nevena; Costantino, Rossella; Mormina, Enrico Maria; Ceravolo, Roberto; Saitta, Antonino; Dattilo, Giuseppe

    2015-12-01

    Left ventricular ejection fraction (LVEF) and pulse wave velocity (PWV) are acknowledged as independent risk factors in different high-risk populations. We investigated the effects of arterial stiffness on LV function at 3 and 6 months after acute myocardial infarction. Changes in LVEF were evaluated in 136 consecutive patients who were diagnosed with ST-segment elevation coronary syndrome and treated with primary percutaneous coronary intervention. Doppler guided by 2D ultrasound was used to measure carotid-femoral PWV. According to tertiles of arterial stiffness, a significant correlation between higher PWV and worse recovery in LVEF was found (3 months EF change: 9.9 ± 5.0% vs 5.9 ± 3.4 vs 3.8 ± 1.6; p < 0.001 and 6 months EF change: 18.5 ± 7.0% vs 11.5 ± 5.2 vs 7.3 ± 3.0; p = 0.002). In the multivariate analysis PWV showed the ability to predict the outcome in terms of EF recovery at 3 and 6 months also after any correction for age and other variables (β = -0.566, p < 0.001). Arterial stiffening may result in a less effective recovery of LV function after acute myocardial infarction.

  14. Percutaneous stenting of a dissected superior mesenteric artery in a patient with previous surgical repair of Stanford type A aortic dissection.

    PubMed

    Hatzidakis, A; Krokidis, M; Androulakakis, Z; Rossi, M

    2015-01-01

    We report a case of a 54-year-old male patient with background history of hypertension, which suffered a Stanford type A thoraco-abdominal aortic dissection with extension to the visceral arteries. The patient initially underwent surgical repair with replacement of the ascending aorta and of the hemiarch in the acute phase of the dissection. Postoperatively, he developed non-specific abdominal pain that was not related to meals but led to weight loss of 20 kg within the first five post-operative months. Follow-up computerized tomography scan revealed a chronic subphrenic aortic dissection extending to the celiac axis (with involvement of the left gastric and the splenic artery), the left renal artery and the superior mesenteric artery (SMA). The hepatic artery took origin from the SMA and received blood from the true lumen of the vessel, and the right renal artery was entirely supplied from the true aortic lumen. After exclusion of other causes of abdominal pain, the patient was treated with percutaneous stent placement in the dissected SMA with significant improvement of his symptoms. This case report emphasizes the role of visceral artery endovascular techniques in the management of patients with complicated chronic aortic dissection. Hippokratia 2015; 19 (3): 270-273.

  15. Increased pulse wave transit time after percutaneous coronary intervention procedure in CAD patients.

    PubMed

    Ji, Lizhen; Liu, Chengyu; Li, Peng; Wang, Xinpei; Liu, Changchun; Hou, Yinglong

    2018-01-08

    Pulse wave transit time (PWTT) has been widely used as an index in assessing arterial stiffness. Percutaneous coronary intervention (PCI) is usually applied to the treatment of coronary artery disease (CAD). Research on the changes in PWTT caused by PCI is helpful for understanding the impact of the PCI procedure. In addition, effects of stent sites and access sites on the changes in PWTT have not been explored. Consequently, this study aimed to provide this information. The results showed that PWTT significantly increased after PCI (p < 0.01) while the standard deviation (SD) of PWTT time series had no statistically significant changes (p = 0.60) between before and after PCI. Significantly increased PWTT was found in the radial access group (p < 0.01), while there were no significant changes in the femoral access group (p > 0.4). Additionally, PWTT in the left anterior descending (LAD) group significantly increased after PCI (p < 0.01), but the increase that was found in the right coronary artery (RCA) group was not significant (p > 0.1). Our study indicates that arterial elasticity and left ventricular functions can benefit from a successful PCI procedure, and the increase of peripheral PWTT after PCI can help to better understand the effectiveness of the procedure.

  16. eFAST for the diagnosis of a perioperative complication during percutaneous nephrolithotomy.

    PubMed

    Sharma, Achyut; Bhattarai, Prajjwal; Sharma, Apurb

    2018-04-03

    A 29-year-old patient with normal preanesthetic evaluation was planned for percutaneous nephrolithotomy (PCNL) for right nephrolithiasis with right pyelolithiasis. Surgery was performed under general anesthesia with endotracheal intubation with muscle relaxation. At the conclusion of surgery, when the patient was turned over to supine position, tense abdomen was noted. Immediately extended focused assessment with sonography in trauma (eFAST) was done in which both right and left quadrants of abdomen including pericardial and suprapubic region, right and left thoracic, and both lung basis were examined. Fluid collection was seen in Morison's pouch which was drained by the urologist under real-time ultrasonography guidance by anesthesiologist. Distension of abdomen subsequently subsided and patient had normal vitals. Trachea was extubated and patient shifted to post-operative ward. eFAST and FAST scans are routine procedures in the rapid assessment of trauma victims in emergency settings. The fluid extravasation during a routine PCNL procedure may lead to abdominal compartment syndrome. This case demonstrated that use of eFAST rapidly detected abdominal collection and ruled out life-threatening conditions such as hemothorax and pneumothorax and prevented abdominal compartment syndrome. Our case is only an example that potentially lethal conditions like these may be encountered in the perioperative setting and the knowledge of eFAST scan may be of great help.

  17. Use of the Impella 2.5 for prophylactic circulatory support during elective high-risk percutaneous coronary intervention.

    PubMed

    Alasnag, Mirvat A; Gardi, Delair O; Elder, Mahir; Kannam, Hari; Ali, Farhan; Petrina, Mircea; Kheterpal, Vipin; Hout, Mariah S; Schreiber, Theodore L

    2011-01-01

    Patients undergoing percutaneous coronary intervention (PCI) who are at high risk for cardiovascular collapse during the procedure may benefit from prophylactic circulatory support. The objective was to evaluate the safety and feasibility of prophylactic use of the Impella 2.5 during high-risk PCI. We used the Impella 2.5 for partial circulatory support during 60 consecutive elective high-risk PCI cases over 20 months. All patients either were deemed inoperable by the cardiac surgeons or were offered bypass surgery but declined. The patients had multiple risk factors including hypertension (95%), diabetes (52%), chronic pulmonary disease (23%), prior myocardial infarction (62%) and prior bypass surgery (18%). Forty-five percent presented with acute coronary syndrome. The mean left ventricular ejection fraction was 23%±15%. Nearly all patients had multivessel disease (93%), and 60% had left main disease. The average SYNTAX score was 30±9. Despite lesion complexity and high-risk factors, we achieved an angiographic success rate of 96%. Left main lesions were treated in 55% of the patients, and 83% of patients had multiple lesions treated. There was one procedural death. At 30 days postintervention, mortality was 5%, and rates of myocardial infarction, stroke, target vessel revascularization and urgent bypass surgery were 0%. The single-center experience reported here demonstrates that use of the Impella 2.5 during high-risk PCI in the "real world" - outside the controlled environment of a clinical trial - is safe and feasible. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. Relationship between colon and kidney: a critical point for percutaneous procedures.

    PubMed

    Atar, Murat; Hatipoglu, Namik Kemal; Soylemez, Haluk; Penbegul, Necmettin; Bozkurt, Yasar; Gumus, Hatice; Sancaktutar, Ahmet Ali; Kuday, Suzan; Bodakci, Mehmet Nuri

    2013-04-01

    The aim of this study was to determine the frequency of anatomical variations of the colon associated with the kidney. A retrospective analysis was performed on 1000 consecutive abdominal computed tomography (CT) scans performed between July 2010 and September 2011. A line parallel to the horizontal plane was drawn through the posterior edge of each kidney at three renal levels: upper, middle and lower pole. The bowel between the psoas muscle and the kidney was determined as the interposition of the colon. The amount of perinephric fat was estimated and graded. The total number of patients undergoing CT scans was 1000 (male/female = 510/490). The mean age of patients was 42.2 years. Seventeen patients (1.7%) had retrorenal colon, of which 12 (1.2%) were on the left side, three (0.3%) on the right side and two (0.2%) were bilateral. Of these 17 cases, 11 were found at the lower, two at the middle and four at the upper pole of the kidney. There was grade I perirenal fat tissue in 13 and grade II in four cases. Interposition of the colon was detected in 32 (3.2%) patients, 30 (3%) on the right and two (0.2%) on the left. The grade of perirenal fat tissue in patients with colon interposition was as follows: 25 patients grade I, six patients grade II and one patient grade III. In accessing the lower pole of the kidney, especially on the left side, the risk of colonic injury should be taken into consideration during percutaneous procedures, regardless of the patient's age and gender.

  19. Amplification of transcutaneous and percutaneous bone-conduction devices with a test-band in an induced model of conductive hearing loss.

    PubMed

    Park, Marn Joon; Lee, Jae Ryung; Yang, Chan Joo; Yoo, Myung Hoon; Jin, In Suk; Choi, Chi Ho; Park, Hong Ju

    2016-11-01

    Transcutaneous devices have a disadvantage, the dampening effect by soft tissue between the bone and devices. We investigated hearing outcomes with percutaneous and transcutaneous devices using test-bands in an induced unilateral conductive hearing loss. Comparison of hearing outcomes of two devices in the same individuals. The right ear was plugged in 30 subjects and a test-band with devices (Cochlear™ Baha® BP110 Power and Sophono® Alpha-2 MPO™) was applied on the right mastoid tip with the left ear masked. Sound-field thresholds, speech recognition thresholds (SRTs), and word recognition scores (WRSs) were compared. Aided thresholds of Sophono were significantly better than those of Baha at most frequencies. Sophono WRSs (86 ± 12%) at 40 dB SPL and SRTs (14 ± 5 dB HL) were significantly better than those (73 ± 24% and 23 ± 8 dB HL) of Baha. However, Sophono WRSs (98 ± 3%) at 60 dB SPL did not differ from Baha WRSs (95 ± 12%). Amplifications of the current transcutaneous device were not inferior to those of percutaneous devices with a test-band in subjects with normal bone-conduction thresholds. Since the percutaneous devices can increase the gain when fixed to the skull by eliminating the dampening effect, both devices are expected to provide sufficient hearing amplification.

  20. Medical impulsive therapy (MIT): the impact of 1 week of preoperative tamsulosin on deployment of 16-French ureteral access sheaths without preoperative ureteral stent placement.

    PubMed

    Kaler, Kamaljot S; Safiullah, Shoaib; Lama, Daniel J; Parkhomenko, Egor; Okhunov, Zhamshid; Ko, Young H; Huynh, Linda; Patel, Roshan M; Landman, Jaime; Clayman, Ralph V

    2018-05-25

    Medical expulsive therapy is based on pharmacologic ureteral relaxation. We hypothesized this concept may facilitate the deployment of the large 16 French (F) ureteral access sheath (UAS) when patients are intentionally pre-treated with oral tamsulosin, i.e., medical impulsive therapy. We retrospectively analyzed our experience with UAS deployment during endoscopic-guided percutaneous nephrolithotomy in prone position in patients pre-treated for 1 week with oral tamsulosin with a contemporary untreated cohort. Between January 2015 and September 2016, seventy-seven patients without a pre-existing ureteral stent met inclusion criteria. Demographic data, tamsulosin usage, UAS size, deployment failure, ureteral injuries, stone-free rates, and complications were recorded. Univariate and multivariate analysis was conducted to assess the impact of tamsulosin on deployment of the 16F UAS. There was no statistical difference between the tamsulosin (n = 40) group and non-tamsulosin (n = 37) group in regard to demographic data. The tamsulosin group had a significantly higher percentage of 16F UAS deployment, 87 vs. 43% (p < 0.001), and no significant difference in ureteral injuries (p = 0.228). Univariate and multivariate analysis revealed that tamsulosin significantly increased the odds ratio (9.3 and 19.4, respectively) for successful passage of a 16F UAS. Despite a larger stone volume, there was no significant difference in computed tomography scan complete stone-free rates (29 vs. 42%; p = 0.277) at median post-operative time of only 3 days. In this retrospective study, 1 week of preoperative tamsulosin was associated with an increase in the deployment of a 16F UAS in patients without preoperative ureteral stent placement.

  1. Design considerations and quantitative assessment for the development of percutaneous mitral valve stent.

    PubMed

    Kumar, Gideon Praveen; Cui, Fangsen; Phang, Hui Qun; Su, Boyang; Leo, Hwa Liang; Hon, Jimmy Kim Fatt

    2014-07-01

    Percutaneous heart valve replacement is gaining popularity, as more positive reports of satisfactory early clinical experiences are published. However this technique is mostly used for the replacement of pulmonary and aortic valves and less often for the repair and replacement of atrioventricular valves mainly due to their anatomical complexity. While the challenges posed by the complexity of the mitral annulus anatomy cannot be mitigated, it is possible to design mitral stents that could offer good anchorage and support to the valve prosthesis. This paper describes four new Nitinol based mitral valve designs with specific features intended to address migration and paravalvular leaks associated with mitral valve designs. The paper also describes maximum possible crimpability assessment of these mitral stent designs using a crimpability index formulation based on the various stent design parameters. The actual crimpability of the designs was further evaluated using finite element analysis (FEA). Furthermore, fatigue modeling and analysis was also done on these designs. One of the models was then coated with polytetrafluoroethylene (PTFE) with leaflets sutured and put to: (i) leaflet functional tests to check for proper coaptation of the leaflet and regurgitation leakages on a phantom model and (ii) anchorage test where the stented valve was deployed in an explanted pig heart. Simulations results showed that all the stents designs could be crimped to 18F without mechanical failure. Leaflet functional test results showed that the valve leaflets in the fabricated stented valve coapted properly and the regurgitation leakage being within acceptable limits. Deployment of the stented valve in the explanted heart showed that it anchors well in the mitral annulus. Based on these promising results of the one design tested, the other stent models proposed here were also considered to be promising for percutaneous replacement of mitral valves for the treatment of mitral regurgitation, by virtue of their key features as well as effective crimping. These models will be fabricated and put to all the aforementioned tests before being taken for animal trials. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  2. Left main coronary artery obstruction by dislodged native-valve calculus after transcatheter aortic valve replacement.

    PubMed

    Durmaz, Tahir; Ayhan, Huseyin; Keles, Telat; Aslan, Abdullah Nabi; Erdogan, Kemal Esref; Sari, Cenk; Bilen, Emine; Akcay, Murat; Bozkurt, Engin

    2014-08-01

    Transcatheter aortic valve replacement can be an effective, reliable treatment for severe aortic stenosis in surgically high-risk or ineligible patients. However, various sequelae like coronary artery obstruction can occur, not only in the long term, but also immediately after the procedure. We present the case of a 78-year-old woman whose left main coronary artery became obstructed with calculus 2 hours after the transfemoral implantation of an Edwards Sapien XT aortic valve. Despite percutaneous coronary intervention in that artery, the patient died. This case reminds us that early recognition of acute coronary obstruction and prompt intervention are crucial in patients with aortic stenosis who have undergone transcatheter aortic valve replacement.

  3. Stenting for Acute Aortic Dissection with Malperfusion as “Bridge Therapy”

    PubMed Central

    Fujita, Wakako; Taniguchi, Satoshi; Daitoku, Kazuyuki; Fukuda, Ikuo

    2010-01-01

    The most common treatment of acute type A aortic dissection is immediate surgical repair. However, early surgery for acute dissections with peripheral vascular compromise carries a high mortality rate. Herein, we report a case in which we placed percutaneous endovascular stents in a type A dissection patient before proceeding with proximal aortic repair. Bare-metal stents were placed into the obliterated true channel of the abdominal aorta and the left external iliac artery. Endovascular stenting immediately relieved the lower-left-extremity ischemic symptoms, and the patient underwent hemi-arch replacement 7 days after the procedure. Stent placement for patients who have acute aortic dissection with malperfusion can be used as “bridge therapy.” PMID:21224949

  4. A Community-acquired Lung Abscess Attributable to Streptococcus pneumoniae which Extended Directly into the Chest Wall

    PubMed Central

    Ko, Yuki; Tobino, Kazunori; Yasuda, Yuichiro; Sueyasu, Takuto; Nishizawa, Saori; Yoshimine, Kouhei; Munechika, Miyuki; Asaji, Mina; Yamaji, Yoshikazu; Tsuruno, Kosuke; Miyajima, Hiroyuki; Mukasa, Yosuke; Ebi, Noriyuki

    2017-01-01

    We herein report the case of 75-year-old Japanese female with a community-acquired lung abscess attributable to Streptococcus pneumoniae (S. penumoniae) which extended into the chest wall. The patient was admitted to our hospital with a painful mass on the left anterior chest wall. A contrast-enhanced chest computed tomography scan showed a lung abscess in the left upper lobe which extended into the chest wall. Surgical debridement of the chest wall abscess and percutaneous transthoracic tube drainage of the lung abscess were performed. A culture of the drainage specimen yielded S. pneumoniae. The patient showed a remarkable improvement after the initiation of intravenous antibiotic therapy. PMID:28049987

  5. A Community-acquired Lung Abscess Attributable to Streptococcus pneumoniae which Extended Directly into the Chest Wall.

    PubMed

    Ko, Yuki; Tobino, Kazunori; Yasuda, Yuichiro; Sueyasu, Takuto; Nishizawa, Saori; Yoshimine, Kouhei; Munechika, Miyuki; Asaji, Mina; Yamaji, Yoshikazu; Tsuruno, Kosuke; Miyajima, Hiroyuki; Mukasa, Yosuke; Ebi, Noriyuki

    We herein report the case of 75-year-old Japanese female with a community-acquired lung abscess attributable to Streptococcus pneumoniae (S. penumoniae) which extended into the chest wall. The patient was admitted to our hospital with a painful mass on the left anterior chest wall. A contrast-enhanced chest computed tomography scan showed a lung abscess in the left upper lobe which extended into the chest wall. Surgical debridement of the chest wall abscess and percutaneous transthoracic tube drainage of the lung abscess were performed. A culture of the drainage specimen yielded S. pneumoniae. The patient showed a remarkable improvement after the initiation of intravenous antibiotic therapy.

  6. Unprotected Left Main Coronary Artery Disease: Management in the Post NOBLE and EXCEL Era

    PubMed Central

    Kapadia, Samir R; Ellis, Stephen G

    2017-01-01

    The optimal management of unprotected left main coronary artery (ULMCA) disease is currently a debated topic. Percutaneous coronary intervention (PCI) has seen an increased adoption for the management of ULMCA disease after numerous small-scale randomised trials and cohort studies showed equipoise with coronary artery bypass grafting (CABG) for low complexity lesions. The recently published NOBLE and EXCEL trials are two of the largest international randomised clinical trials comparing PCI and CABG in patients with ULMCA disease. In lieu of all the available evidence, PCI appears to be equivalent to CABG in regard to mortality in patients with ULMCA disease. In non-diabetic patients with low complexity coronary disease (SYNTAX score ≤32), PCI appears to be a reasonable alternative to CABG, especially for ostial and midshaft left main coronary lesions. CABG is preferable in the presence of diabetes, multivessel coronary disease in addition to ULMCA or complex coronary lesions (SYNTAX score >33) including distal left main lesions. PMID:29588736

  7. Unprotected Left Main Coronary Artery Disease: Management in the Post NOBLE and EXCEL Era.

    PubMed

    Borges, Nyal; Kapadia, Samir R; Ellis, Stephen G

    2017-09-01

    The optimal management of unprotected left main coronary artery (ULMCA) disease is currently a debated topic. Percutaneous coronary intervention (PCI) has seen an increased adoption for the management of ULMCA disease after numerous small-scale randomised trials and cohort studies showed equipoise with coronary artery bypass grafting (CABG) for low complexity lesions. The recently published NOBLE and EXCEL trials are two of the largest international randomised clinical trials comparing PCI and CABG in patients with ULMCA disease. In lieu of all the available evidence, PCI appears to be equivalent to CABG in regard to mortality in patients with ULMCA disease. In non-diabetic patients with low complexity coronary disease (SYNTAX score ≤32), PCI appears to be a reasonable alternative to CABG, especially for ostial and midshaft left main coronary lesions. CABG is preferable in the presence of diabetes, multivessel coronary disease in addition to ULMCA or complex coronary lesions (SYNTAX score >33) including distal left main lesions.

  8. Left heart pacing lead implantation using subxiphoid videopericardioscopy.

    PubMed

    Zenati, Marco A; Bonanomi, Gianluca; Chin, Albert K; Schwartzman, David

    2003-09-01

    Recent clinical data support the utility of left heart pacing. The transvenous approach for left heart pacing lead implantation is imperfect. A direct epicardial approach may have advantages, but heretofore its utility has been limited because of the requirement for thoracotomy. We sought to examine the feasibility of a method for epicardial lead implantation that did not require thoracotomy. In five large swine, percutaneous access to the epicardium was achieved with subxiphoid videopericardioscopy, using a device that marries endoscopy with a port through which pacing leads could be introduced. In each animal, standard, active fixation pacing leads were implanted onto the left atrium and ventricle. The atrial lead was implanted at the base of the appendage. The ventricular lead was implanted on the anterior, lateral, and inferior walls. Continuous direct visualization of the epicardium provided guidance for lead localization and fixation, including avoidance of complications such as trauma to epicardial coronary vessels. Capture thresholds were uniformly low. Postmortem examination demonstrated anatomically accurate, uncomplicated lead fixation. Using subxiphoid videopericardioscopy, uncomplicated, anatomically accurate left heart epicardial pacing lead implantation can be achieved without thoracotomy.

  9. [Biomechanics changes of lumbar spine caused by foraminotomy via percutaneous transforaminal endoscopic lumbar discectomy].

    PubMed

    Qian, J; Yu, S S; Liu, J J; Chen, L; Jing, J H

    2018-04-03

    Objective: To analyze the biomechanics changes of lumbar spine caused by foraminotomy via percutaneous transforaminal endoscopic lumbar discectomy using the finite element method. Methods: Three healthy adult males (aged 35.6 to 42.3 years) without spinal diseases were enrolled in this study and 3D-CT scans were carried out to obtain the parameters of lumbar spine. Mimics software was applied to build a 3D finite element model of lumbar spine. Graded resections (1/4, 2/4, 3/4 and 4/4) of the left superior articular process of L(5) were done via percutaneous transforaminal endoscopic lumbar discectomy. Then, the pressure of the L(4/5) right facets, the pressure of the L(4/5) intervertebral disc and the motion of lumbar spine were recorded after simulating the normal flexion and extension, lateral flexion and rotation of the lumbar spine model during different resections. The data were compared among groups with analysis of variance. Results: Comparing with the normal group, after 1/4 resection of the left superior articular process of L(5), the pressure of the L(4/5) right facets showed significant differences during left lateral flexion and rotation of lumbar spine ( q =8.823, 8.248, both P <0.05); and the pressure of L(4/5) intervertebral disc also changed significantly during extension and right rotation of lumbar spine ( q =6.918, 6.438, both P <0.05); the motion of lumbar spine showed obvious differences during right lateral flexion and rotation ( q =6.845, 7.772, 13.58, all P <0.05). Comparing with the normal group, after 2/4 resection of the left superior articular process of L(5), the pressure of the L(4/5) right facets presented significant differences during all conditions ( q =5.670-17.830, all P <0.05); the pressure of L(4/5) intervertebral disc changed significantly during flexion, extension, lateral flexion and right rotation ( q =5.260, 17.150, 5.727, 8.890, 15.660, all P <0.05); the motion of lumbar spine also existed differences during extension, lateral flexion and rotation ( q =9.106, 5.431, 12.060, 11.160, 17.260, all P <0.05). However, after 3/4 resections, the pressure of the L(4/5) right facets, the pressure of the L(4/5) intervertebral disc and the motion of lumbar spine presented differences during all conditions when compared with those in normal group ( q =6.303-25.48, all P <0.05). After 4/4 resections, the pressure of the L(4/5) right facets and the pressure of the L(4/5) intervertebral disc and the motion of lumbar spine showed significant differences during all conditions when compared with those in normal group ( q =8.065-45.70, all P <0.05). Conclusions: The biomechanics and the stability of lumbar spine changed partly after 1/4 resection of the superior articular process and obviously after more than 2/4 is resected. The superior articular process should be paid more attention during foraminotomy via percutaneous transforaminal endoscopic lumbar discectomy.

  10. Revascularization for Left Main and Multivessel Coronary Artery Disease: Current Status and Future Prospects after the EXCEL and NOBLE Trials

    PubMed Central

    2018-01-01

    Revascularization of severe left main and multivessel coronary artery disease has been shown to improve survival in both stable ischemic heart disease and acute coronary syndrome. While revascularization with coronary artery bypass surgery for these disease entities carries class I recommendation in most current guidelines, recent trials has shown potential comparable survival and cardiovascular outcomes between percutaneous and surgical interventions in patients with less complex coronary anatomy. Despite the conflicting results observed in the most recent left main revascularization trials, Everolimus-Eluting Stents or Bypass Surgery for Left Main Coronary Artery Disease (EXCEL) and Nordic-Baltic-British left main revascularization (NOBLE), both treatment strategies remain important for the management of left main disease (LMD) and multivessel disease (MVD) reflecting on the importance of heart team discussion. This review is focused on revascularization of LMD and MVD in patients who are not presenting with ST-segment elevation myocardial infarction, encompassing the evidence from historic and contemporary trials which shaped up current practices. This review discusses the heart team approach to guide decision making, including special populations that are not represented in clinical trials. PMID:29856140

  11. Revascularization for Left Main and Multivessel Coronary Artery Disease: Current Status and Future Prospects after the EXCEL and NOBLE Trials.

    PubMed

    Al-Hijji, Mohammed; El Sabbagh, Abdallah; Holmes, David R

    2018-06-01

    Revascularization of severe left main and multivessel coronary artery disease has been shown to improve survival in both stable ischemic heart disease and acute coronary syndrome. While revascularization with coronary artery bypass surgery for these disease entities carries class I recommendation in most current guidelines, recent trials has shown potential comparable survival and cardiovascular outcomes between percutaneous and surgical interventions in patients with less complex coronary anatomy. Despite the conflicting results observed in the most recent left main revascularization trials, Everolimus-Eluting Stents or Bypass Surgery for Left Main Coronary Artery Disease (EXCEL) and Nordic-Baltic-British left main revascularization (NOBLE), both treatment strategies remain important for the management of left main disease (LMD) and multivessel disease (MVD) reflecting on the importance of heart team discussion. This review is focused on revascularization of LMD and MVD in patients who are not presenting with ST-segment elevation myocardial infarction, encompassing the evidence from historic and contemporary trials which shaped up current practices. This review discusses the heart team approach to guide decision making, including special populations that are not represented in clinical trials. Copyright © 2018. The Korean Society of Cardiology.

  12. Post-deployment family violence among UK military personnel.

    PubMed

    Kwan, Jamie; Jones, Margaret; Somaini, Greta; Hull, Lisa; Wessely, Simon; Fear, Nicola T; MacManus, Deirdre

    2017-12-19

    Research into violence among military personnel has not differentiated between stranger- and family-directed violence. While military factors (combat exposure and post-deployment mental health problems) are risk factors for general violence, there has been limited research on their impact on violence within the family environment. This study aims to compare the prevalence of family-directed and stranger-directed violence among a deployed sample of UK military personnel and to explore risk factors associated with both family- and stranger-directed violence. This study utilised data from a large cohort study which collected information by questionnaire from a representative sample of randomly selected deployed UK military personnel (n = 6711). The prevalence of family violence immediately following return from deployment was 3.6% and 7.8% for stranger violence. Family violence was significantly associated with having left service, while stranger violence was associated with younger age, male gender, being single, having a history of antisocial behaviour as well as having left service. Deployment in a combat role was significantly associated with both family and stranger violence after adjustment for confounders [adjusted odds ratio (aOR) = 1.92 (1.25-2.94), p = 0.003 and aOR = 1.77 (1.31-2.40), p < 0.001, respectively], as was the presence of symptoms of post-traumatic stress disorder, common mental disorders and aggression. Exposure to combat and post-deployment mental health problems are risk factors for violence both inside and outside the family environment and should be considered in violence reduction programmes for military personnel. Further research using a validated measurement tool for family violence would improve comparability with other research.

  13. Long-Term Prognostic Implications of the Admission Shock Index in Patients With Acute Myocardial Infarction Who Received Percutaneous Coronary Intervention.

    PubMed

    Abe, Naoyuki; Miura, Takashi; Miyashita, Yusuke; Hashizume, Naoto; Ebisawa, Soichiro; Motoki, Hirohiko; Tsujimura, Takuya; Ishihara, Takayuki; Uematsu, Masaaki; Katagiri, Toshio; Ishihara, Ryuma; Tosaka, Atsushi; Ikeda, Uichi

    2017-04-01

    The admission shock index (SI) enables prediction of short-term prognosis. This study investigated the prognostic implications of admission SI for predicting long-term prognoses for acute myocardial infarction (AMI). The participants were 680 patients with AMI who received percutaneous coronary intervention. Shock index is the ratio of heart rate and systolic blood pressure. Patients were classified as admission SI <0.66 (normal) and ≥0.66 (elevated; 75th percentile). The end point was 5-year major adverse cardiac events (MACEs). Elevated admission SI was seen in 176 patients. Peak creatine kinase levels were significantly higher and left ventricular ejection fraction was lower in the elevated SI group, which had a worse MACEs. In multivariate Cox regression analysis, SI ≥0.66 was a risk factor for MACE. Elevated admission SI was associated with poorer long-term prognosis.

  14. Reversal of pulmonary hypertension after percutaneous closure of congenital renal arteriovenous fistula in a 74-year old woman.

    PubMed

    Brar, Vijaywant; Bernardo, Nelson; Suddath, William; Weissman, Gaby; Asch, Federico; Campia, Umberto

    2015-01-01

    We report the case of a large right renal arteriovenous fistula (AVF) in a 74-year old woman who presented with heart failure. Transthoracic echocardiography revealed normal left ventricular size and systolic function (ejection fraction 60-65%), moderately dilated right ventricle with severely depressed systolic function, and severe pulmonary hypertension. Right heart catheterization confirmed the elevated pulmonary pressures and showed a high cardiac output. Physical examination was remarkable for a right flank bruit. An abdominal ultrasound revealed an AVF originating from the distal right renal artery and dilated suprarenal inferior vena cava and hepatic veins. These findings were confirmed with an abdominal MRI. Percutaneous endovascular closure of the right renal AVF was successfully performed, with immediate reduction of pulmonary pressures and normalization of cardiac output. The patient's symptoms improved, and a post intervention echocardiogram revealed normalization of right ventricular size. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. The 'MAP strategy' (Maximum aspiration of atherothrombus and adjunctive glycoprotein IIb/IIIa inhibitor utilization combined with prolonged inflation of balloon/stent) for preventing no-reflow in patients with ST-segment elevation myocardial infarction undergoing percutaneous coronary intervention: A retrospective analysis of seventy-one cases.

    PubMed

    Potdar, Anil; Sharma, Satyavan

    2015-12-01

    'No-reflow' phenomenon is a common occurrence in percutaneous coronary intervention (PCI). A three-component 'MAP strategy' was designed to prevent no-reflow by addressing both intralesional and intraluminal thrombus in patients with ST-segment elevation myocardial infarction (STEMI). In this analysis, we observed Thrombolysis In Myocardial Infarction (TIMI) flow grade 3 or 2 in all patients, with no incidence of no-reflow. Myocardial blush grade (MBG) 3 or 2 was observed in most (87.32%) patients. Left ventricular ejection fraction (LVEF) was improved, without any incidence of death up to 9-month follow-up. All patients safely tolerated the strategy-driven prolonged, 35-s inflation of the balloon/stent. Copyright © 2016. Published by Elsevier B.V.

  16. Breast cancer metastatic to the kidney with renal vein involvement.

    PubMed

    Nasu, Hatsuko; Miura, Katsutoshi; Baba, Megumi; Nagata, Masao; Yoshida, Masayuki; Ogura, Hiroyuki; Takehara, Yasuo; Sakahara, Harumi

    2015-02-01

    The common sites of breast cancer metastases include bones, lung, brain, and liver. Renal metastasis from the breast is rare. We report a case of breast cancer metastatic to the kidney with extension into the renal vein. A 40-year-old woman had undergone left mastectomy for breast cancer at the age of 38. A gastric tumor, which was later proved to be metastasis from breast cancer, was detected by endoscopy. Computed tomography performed for further examination of the gastric tumor revealed a large left renal tumor with extension into the left renal vein. It mimicked a primary renal tumor. Percutaneous biopsy of the renal tumor confirmed metastasis from breast cancer. Surgical intervention of the stomach and the kidney was avoided, and she was treated with systemic chemotherapy. Breast cancer metastatic to the kidney may present a solitary renal mass with extension into the renal vein, which mimics a primary renal tumor.

  17. Complete filter-based cerebral embolic protection with transcatheter aortic valve replacement.

    PubMed

    Van Gils, Lennart; Kroon, Herbert; Daemen, Joost; Ren, Claire; Maugenest, Anne-Marie; Schipper, Marguerite; De Jaegere, Peter P; Van Mieghem, Nicolas M

    2018-03-01

    To evaluate the value of left vertebral artery filter protection in addition to the current filter-based embolic protection technology to achieve complete cerebral protection during TAVR. The occurrence of cerebrovascular events after transcatheter aortic valve replacement (TAVR) has fueled concern for its potential application in younger patients with longer life expectancy. Transcatheter cerebral embolic protection (TCEP) devices may limit periprocedural cerebrovascular events by preventing macro and micro-embolization to the brain. Conventional filter-based TCEP devices cover three extracranial contributories to the brain, yet leave the left vertebral artery unprotected. Patients underwent TAVR with complete TCEP. A dual-filter system was deployed in the brachiocephalic trunk and left common carotid artery with an additional single filter in the left vertebral artery. After TAVR all filters were retrieved and sent for histopathological evaluation by an experienced pathologist. Eleven patients received a dual-filter system and nine of them received an additional left vertebral filter. In the remaining two patients, the left vertebral filter could not be deployed. No periprocedural strokes occurred. We found debris in all filters, consisting of thrombus, tissue derived debris, and foreign body material. The left vertebral filter contained debris in an equal amount of patients as the Sentinel filters. The size of the captured particles was similar between all filters. The left vertebral artery is an important entry route for embolic material to the brain during TAVR. Selective filter protection of the left vertebral artery revealed embolic debris in all patients. The clinical value of complete filter-based TCEP during TAVR warrants further research. © 2017 Wiley Periodicals, Inc.

  18. Validating the EXCEL hypothesis: a propensity score matched 3-year comparison of percutaneous coronary intervention versus coronary artery bypass graft in left main patients with SYNTAX score ≤32.

    PubMed

    Capodanno, Davide; Caggegi, Anna; Capranzano, Piera; Cincotta, Glauco; Miano, Marco; Barrano, Gionbattista; Monaco, Sergio; Calvo, Francesco; Tamburino, Corrado

    2011-06-01

    The aim of this study is to verify the study hypothesis of the EXCEL trial by comparing percutaneous coronary intervention (PCI) and coronary artery bypass graft (CABG) in an EXCEL-like population of patients. The upcoming EXCEL trial will test the hypothesis that left main patients with SYNTAX score ≤ 32 experience similar rates of 3-year death, myocardial infarction (MI), or cerebrovascular accidents (CVA) following revascularization by PCI or CABG. We compared the 3-year rates of death/MI/CVA and death/MI/CVA/target vessel revascularization (MACCE) in 556 patients with left main disease and SYNTAX score ≤ 32 undergoing PCI (n = 285) or CABG (n = 271). To account for confounders, outcome parameters underwent extensive statistical adjustment. The unadjusted incidence of death/MI/CVA was similar between PCI and CABG (12.7% vs. 8.4%, P = 0.892), while MACCE were higher in the PCI group compared to the CABG group (27.0% vs. 11.8%, P < 0.001). After propensity score matching, PCI was not associated with a significant increase in the rate of death/MI/CVA (11.8% vs. 10.7%, P = 0.948), while MACCE were more frequently noted among patients treated with PCI (28.8% vs. 14.1%, P = 0.002). Adjustment by means of SYNTAX score and EUROSCORE, covariates with and without propensity score, and propensity score alone did not change significantly these findings. In an EXCEL-like cohort of patients with left main disease, there seems to be a clinical equipoise between PCI and CABG in terms of death/MI/CVA. However, even in patients with SYNTAX score ≤ 32, CABG is superior to PCI when target vessel revascularization is included in the combined endpoint. Copyright © 2011 Wiley-Liss, Inc.

  19. Percutaneous intervention versus coronary artery bypass graft surgery in left main coronary artery stenosis: a systematic review and meta-analysis.

    PubMed

    Zhang, Xin-Lin; Zhu, Qing-Qing; Yang, Jing-Jing; Chen, Yu-Han; Li, Yang; Zhu, Su-Hui; Xie, Jun; Wang, Lian; Kang, Li-Na; Xu, Biao

    2017-04-21

    The optimal revascularization technique in patients with left main coronary artery disease (CAD) remains controversial. We aimed to compare the long-term performance of percutaneous coronary intervention (PCI) versus coronary artery bypass graft (CABG) surgery in treatment of left main CAD. PubMed, EMBASE, and the Cochrane Library were searched until November 16, 2016. Six randomized controlled trials and 22 matched observational studies including 22,487 patients and 90,167 patient-years of follow-up were included. PCI was associated with an overall higher risk for the major adverse cardiac and cerebrovascular events (hazard ratio (HR), 1.42; 95% confidence interval (CI), 1.14-1.77), mainly driven by higher rates of myocardial infarction (HR, 1.69; 95% CI, 1.22-2.34) and revascularization (HR, 2.80; 95% CI, 1.86-4.22). The overall risks for all-cause death (HR, 1.05; 95% CI, 0.93-1.20), cardiac death (HR, 1.05; 95% CI, 0.69-1.59), stroke (HR, 0.64; 95% CI, 0.33-1.24), and the composite safety endpoint of death, myocardial infarction, or stroke (HR, 1.06; 95% CI, 0.97-1.16) were similar between PCI and CABG. Stratified analysis based on stent types showed that the increased risk for myocardial infarction associated with PCI was only evident in patients with bare-metal stents or early-generation drug-eluting stents (DES), but not newer-generation DES. Stratified analyses based on study designs showed largely similar findings with the overall analyses, except for a significantly higher incidence of myocardial infarction in adjusted studies (HR, 2.01; 95% CI, 1.64-2.45) but a trend toward higher incidence in randomized trials (HR, 1.39; 95% CI, 0.85-2.27) associated with PCI. Compared with CABG, PCI with newer-generation DES might be a safe alternative revascularization strategy for treatment of left main CAD, but is associated with more repeat revascularization.

  20. Artists concept of Apollo 15 crewmen performing deployment of LRV

    NASA Image and Video Library

    1971-06-26

    S71-38188 (26 June 1971) --- An artist's concept showing the Apollo 15 mission commander and the lunar module pilot performing deployment of the Lunar Roving Vehicle (LRV) on the lunar surface. The figure on the left represents astronaut James B. Irwin, lunar module pilot, who here is maintaining a constant pull on the deployment cable to help the LRV unfold, while astronaut David R. Scott (right), commander, pulls the tapes that lower the LRV to the surface. (This is the third in a series of Grumman Aerospace Corporation artist's concepts telling the lunar surface LRV deployment story of the Apollo 15 mission).

  1. [Non-pharmacologic therapy of hypertrophic obstructive cardiomyopathy--results of therapy based on percutaneous transluminal septal myocardial ablation compared with results of dual-chamber cardiac pacing].

    PubMed

    Krejcí, J; Groch, L; Meluzín, J; Vykypel, T; Halámek, J; Vitovec, J

    2006-04-01

    Percutaneous transluminal septal myocardial ablation (PTSMA) and pacemaker (PM) therapy with apical preexcitation are therapeutic options for hypertrophic obstructive cardiomyopathy (HOCM) patients with symptoms despite pharmacological therapy. evaluation and comparison of treatment results of PTSMA and PM implantation. 22 HOCM patients (NYHA class III and IV) with left ventricle outflow tract gradient (LVOTG) at rest more than 30 mm Hg. In group A were evaluated 11 patients treated by PTSMA. Left ventricle outflow tract gradient (LVOTG) was 90.5 +/- 16.0 mm Hg, NYHA class 3.1 +/- 0.2. Group B included 11 patients treated by dual chamber PM implantation, LVOTG in this group was 105 +/- 48 mm Hg, NYHA class 3.0 +/- 0.4. NYHA class in the group A decreased after treatment to 1.8 +/- 0.6 (p < 0.01), LVOTG to 24 +/- 12 mm Hg (p < 0.001). There was observed significant decrease in grade of systolic anterior motion (SAM), interventricular septum (IVS) thickness and left atrium (LA) size. Left ventricle end systolic diameter (LV SD) and left ventricle end diastolic diameter (LV DD) increased during follow-up. Decrease of NYHA class in the group B was to 2.1 +/- 0.6 (p < 0.001), LVOTG to 25.5 +/- 21.0 mm Hg (p < 0.001). Changes of other parameters in the group B were not significant, except decrease of SAM. Comparison of both groups: NYHA class change PTSMA/PM: 1.3 +/- 0.6/0.9 +/- 0.4 (p < 0.05), LVOTG change PTSMA/PM: -66 +/- 20/-79 +/- 46 mm Hg (p = n.s.). LV SD assessment comparison of LV SD change PTSMA/PM: 5 +/- 5/1 +/- 5 mm (p < 0.05). LA assessment - comparison of LA change PTSMA/PM: 5 +/- 5/-1 +/- 4 mm (p < 0.05). Other changes were not significant. Both therapeutic approaches - PTSMA and PM implantation - resulted in significant improvement of functional capacity assessed by NYHA classification. Decrease of LVOTG was also significant and was similar in both groups, NYHA class improvement as well as LA size decrease and LV DS increase were more expressed in PTSMA group.

  2. Prevalence and Predictive Value of Microvascular Flow Abnormalities after Successful Contemporary Percutaneous Coronary Intervention in Acute ST-Segment Elevation Myocardial Infarction.

    PubMed

    Aggarwal, Sourabh; Xie, Feng; High, Robin; Pavlides, Gregory; Porter, Thomas R

    2018-06-01

    Although microvascular flow abnormalities have been observed following epicardial recanalization in acute ST-segment elevation myocardial infarction (STEMI), the prevalence and severity of these abnormalities in the current era of rapid percutaneous coronary intervention (PCI) has not been evaluated. The objective of this study was to assess microvascular perfusion (MVP) following successful primary PCI in patients with STEMI and how it affects clinical outcome. In this single-center, retrospective study, 170 patients who successfully underwent emergent PCI for STEMI were assessed using real-time myocardial contrast echocardiography using a continuous infusion of intravenous commercial microbubbles (3% Definity). Three patterns of myocardial contrast replenishment were observed following intermittent high-mechanical index impulses: infarct zone replenishment within 4 sec (normal MVP), delays in contrast replenishment but normal plateau intensity (delayed MVP [dMVP]), and both delays in replenishment and reduced plateau intensity (microvascular obstruction [MVO]). Changes in left ventricular ejection fraction at 6 months and clinical event rate at 12 months (death, recurrent infarction, need for defibrillator placement, or heart failure admission) were compared. Normal MVP was seen in 62 patients (36%), dMVP in 49 (29%), and MVO in 59 (35%). Left anterior descending coronary artery infarct location was the only parameter independently associated with dMVP or MVO, independent of age, cardiac risk factors, door-to-dilation time, pre-PCI Thrombolysis In Myocardial Infarction flow grade, and thrombus burden. A dMVP pattern had a similar reduction in left ventricular ejection fraction as MVO at hospital discharge but had recovery of left ventricular ejection fraction at 6 months and a greater than fourfold lower event rate than the MVO group (P < .001). MVO and dMVP are frequently seen following contemporary successful PCI for STEMI, especially following left anterior descending coronary artery infarction. Despite a similar area at risk, a dMVP pattern has better functional recovery and clinical outcome than MVO. Copyright © 2018 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  3. Percutaneous Instrumentation of a Complex Lumbar Spine Fracture with Bilateral Pedicle Dissociation: Case Report and Technical Note.

    PubMed

    Luther, Evan; Urakov, Timur; Vanni, Steven

    2018-06-11

     Complex traumatic lumbar spine fractures are difficult to manage and typically occur in younger patients. Surgical immobilization for unstable fractures is an accepted treatment but can lead to future adjacent-level disease. Furthermore, large variations in fracture morphology create significant difficulties when attempting fixation. Therefore, a surgical approach that considers both long-term outcomes and fracture type is of utmost importance. We present a novel technique for percutaneous fixation without interbody or posterolateral fusion in a young patient with bilateral pedicle dissociations and an acute-onset incomplete neurologic deficit.  A 20-year-old man involved in a motorcycle accident presented with unilateral right lower extremity paresis and sensory loss with intact rectal tone and no saddle anesthesia. Lumbar computed tomography (CT) demonstrated L2 and L3 fractures associated with bilateral pedicle dislocations. Lumbar magnetic resonance imaging showed draping of the conus medullaris/cauda equina anteriorly over the kyphotic deformity at L2 with minimal associated canal stenosis at L2 and L3. He was treated with emergent percutaneous fixation of the fracture segment without interbody or posterolateral fusion. Decompression was not performed because of the negligible amount of canal stenosis and high likelihood of cerebrospinal fluid leakage due to dural tears from the fractures. Surgical fixation of the L2 vertebra was achieved by cannulating the left pedicle with an oversized tap while holding the right pedicle in place with a normal tap and then driving screws into the left and right pedicles, respectively, thus reducing the free-floating fracture segment. At 18 months after surgery, a follow-up CT demonstrated good cortication across the prior pedicle fractures, and the instrumentation was removed without any obvious signs of instability or disruption of the alignment at the thoracolumbar junction.  We present a novel technique for percutaneous reduction and fixation of bilateral pedicle fractures with significant dissociation from the vertebral body, associated neural compression from the kyphotic deformity, and minimal spinal canal stenosis. Furthermore, we argue that early fixation and reduction of the fracture prevented irreversible neurologic compromise, and the absence of interbody or posterolateral fusion ultimately preserved the spinal mobility of the patient once the hardware was removed. Georg Thieme Verlag KG Stuttgart · New York.

  4. Extracorporeal Membrane Oxygenation for Refractory Cardiac Arrest

    PubMed Central

    Conrad, Steven A; Rycus, Peter T

    2017-01-01

    Extracorporeal cardiopulmonary resuscitation (ECPR) is the use of rapid deployment venoarterial (VA) extracorporeal membrane oxygenation to support systemic circulation and vital organ perfusion in patients in refractory cardiac arrest not responding to conventional cardiopulmonary resuscitation (CPR). Although prospective controlled studies are lacking, observational studies suggest improved outcomes compared with conventional CPR when ECPR is instituted within 30–60 min following cardiac arrest. Adult and pediatric patients with witnessed in-hospital and out-of-hospital cardiac arrest and good quality CPR, failure of at least 15 min of conventional resuscitation, and a potentially reversible cause for arrest are candidates. Percutaneous cannulation where feasible is rapid and can be performed by nonsurgeons (emergency physicians, intensivists, cardiologists, and interventional radiologists). Modern extracorporeal systems are easy to prime and manage and are technically easy to manage with proper training and experience. ECPR can be deployed in the emergency department for out-of-hospital arrest or in various inpatient units for in-hospital arrest. ECPR should be considered for patients with refractory cardiac arrest in hospitals with an existing extracorporeal life support program, able to provide rapid deployment of support, and with resources to provide postresuscitation evaluation and management. PMID:28074817

  5. Chronic Left Lower Lobe Pulmonary Infiltrates During Military Deployment.

    PubMed

    Hunninghake, John C; Skabelund, Andrew J; Morris, Michael J

    2016-08-01

    Deployment to Southwest Asia is associated with increased airborne hazards such as geologic dusts, burn pit smoke, vehicle exhaust, or air pollution. There are numerous ongoing studies to evaluate the potential effects of inhaled particulate matter on reported increases in acute and chronic respiratory symptoms. Providers need to be aware of potential causes of pulmonary disease such as acute eosinophilic pneumonia, asthma, and vocal cord dysfunction that have been associated with deployment. Other pulmonary disorders such as interstitial lung disease are infrequently reported. Not all deployment-related respiratory complaints may result from deployment airborne hazards and a broad differential should be considered. We present the case of a military member with a prolonged deployment found to have lobar infiltrates secondary to pulmonary vein stenosis from treatment for atrial fibrillation. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.

  6. Minimally invasive therapy of pseudoaneurysms of the trunk: application of thrombin.

    PubMed

    Schellhammer, Frank; Steinhaus, Daniele; Cohnen, Mathias; Hoppe, Jonas; Mödder, Ulrich; Fürst, Günter

    2008-01-01

    Thrombin injection has been proven to be successful in postcatheterization pseudoaneurysms. However, there are only a few reports on the treatment of pseudoaneurysms of the trunk. We report our first experiences using a percutaneous as well as an endovascular access. Eight iatrogenic pseudoaneurysms of the trunk (aorta, n = 4; pulmonary artery, n = 1; gastroduodenal artery, n = 1; left gastric artery, n = 1, renal artery, n = 1) were treated either percutaneously using CT guidance (n = 3) or via an endovascular access (n = 5). Noninvasive control angiograms were performed at day 1 and weeks 1 and 3 by either CT or MR angiography. The total volume of the pseudoaneurysms was 31.2 +/- 23.1 ml on average, with a mean volume of the perfused aneurysmal lumen of 12.9 +/- 7.2 ml. The maximum diameter was 4.1 +/- 1.39 cm on average. In each case, the aneurysmal neck was not wider than 2 mm. One pseudoaneurysm occluded spontaneously following selective catheterization. The remaining pseudoaneurysms were successfully treated by injection of 765 +/- 438.1 IU thrombin. In one individual, a nontarget embolization occurred, as well as an intervention-associated rupture of a pseudoaneurysm. High-grade stenoses of the donor artery were found in a different case. Only once was the endoluminal access converted to a percutaneous one. Thrombin injection might be a future first-line treatment of vascular lesions such as pseudoaneurysms of the trunk. In our experience both percutanous and endoluminal access are technically feasible and safe. However, further experiences are mandatory, especially concerning the question of dosage and long-term results.

  7. Percutaneous Angioplasty of Portal Vein Stenosis that Complicates Liver Transplantation: The Mid-Term Therapeutic Results

    PubMed Central

    Park, Kwang Bo; Do, Young Soo; Shin, Sung Wook; Cho, Sung Gi; Choo, In-Wook

    2005-01-01

    Objective We wanted to valuate the mid-term therapeutic results of percutaneous transhepatic balloon angioplasty for portal vein stenosis after liver transplantation. Materials and Methods From May 1996 to Feb 2005, 420 patients underwent liver transplantation. Percutaneous transhepatic angioplasty of the portal vein was attempted in six patients. The patients presented with the clinical signs and symptoms of portal venous hypertension or they were identified by surveillance doppler ultrasonography. The preangioplasty and postangioplasty pressure gradients were recorded. The therapeutic results were monitored by the follow up of the clinical symptoms, the laboratory values, CT and ultrasonography. Results The overall technical success rate was 100%. The clinical success rate was 83% (5/6). A total of eight sessions of balloon angioplasty were performed in six patients. The mean pressure gradient decreased from 14.5 mmHg to 2.8 mmHg before and after treatment, respectively. The follow up periods ranged from three months to 64 months (mean period; 32 months). Portal venous patency was maintained in all six patients until the final follow up. Combined hepatic venous stenosis was seen in one patient who was treated with stent placement. One patient showed puncture tract bleeding, and this patient was treated with coil embolization of the right portal puncture tract via the left transhepatic portal venous approach. Conclusion Percutaneous transhepatic balloon angioplasty is an effective treatment for the portal vein stenosis that occurs after liver transplantation, and our results showed good mid-term patency with using this technique. PMID:16145291

  8. High-risk PCI: how to define it today?

    PubMed

    DE Marzo, Vincenzo; D'Amario, Domenico; Galli, Mattia; Vergallo, Rocco; Porto, Italo

    2018-04-11

    Before the percutaneous spread, the mortality rate of patients with coronary heart disease not suitable for cardiac surgery was markedly high. This limit has been progressively exceeded with the advent of minimally invasive approaches, which, although was initially intended exclusively for low risk patients, was then employed in complex patients often too compromised to undergo cardiac surgery. Given to the rising of high-risk population, due to an increase of patients with multiple chronic conditions linked to the best care offered, we are witnessing an expansion of the high-risk percutaneous coronary interventions (PCI) population. Despite defining what high-risk is remains still unclear, all proposed definitions of high-risk PCI combine features related to three clinical areas: 1) patient risk factors and comorbidities (incorporating those which preclude surgical or percutaneous revascularization such as diabetes, COPD, CKD, lung disease, frailty, advanced age); 2) location of the disease and complexity of coronary anatomy (including multi-vessel disease, left main disease, CTO, bifurcations); 3) hemodynamic clinical status (ventricular dysfunction, concomitant valvular disease or unstable characteristics). Since cardiologists have ascertained the encouraging results in terms of efficacy and rewards compared to the low-risks patients, the important role of treating high-risk patients is becoming more and more relevant to the point that current guidelines have now changed the appropriateness of percutaneous interventions indications. Considering the complexity in managing higher-risk patients with coronary artery disease, the next step to ensure the best care for this type of patients is to create a team-based model of cooperation in order to properly establish the right treatment for the right patient.

  9. Impella 2.5 initiated prior to unprotected left main PCI in acute myocardial infarction complicated by cardiogenic shock improves early survival.

    PubMed

    Meraj, Perwaiz M; Doshi, Rajkumar; Schreiber, Theodore; Maini, Brijeshwar; O'Neill, William W

    2017-06-01

    To assess post-procedural outcomes when Impella 2.5 percutaneous left ventricular assist device (pLVAD) support is initiated either prior to or after percutaneous coronary intervention (PCI) on unprotected left main coronary artery (ULMCA) culprit lesion in the context of acute myocardial infarction cardiogenic shock (AMICS). Initiation of Impella 2.5 pLVAD prior to PCI is associated with significant survival benefit in the setting of AMICS. Outcomes of those presenting with a ULMCA culprit lesion in this setting have not been well characterized. Thirty-six consecutive patients in the cVAD Registry supported with Impella 2.5 pLVAD for AMICS who underwent PCI on ULMCA culprit lesion were included in our multicenter study. The average age was 69.8 ± 14.2 years, 77.8% were male, 72.7% were in CS at admission, 44.4% sustained one or multiple cardiac arrests, and 30.6% had anoxic brain injury. Baseline characteristics were comparable between the Pre-PCI group (n = 20) and Post-PCI group (n = 16). Non-ST segment elevation myocardial infarction and greater coronary disease burden were significantly more frequent in the Pre-PCI group but they had significantly better survival to discharge (55.0% vs 18.8%, P = 0.041). Kaplan-Meier 30-day survival analysis showed very poor survival in Post-PCI group (48.1% vs 12.5%, Log-Rank P = 0.004). Initiation of Impella 2.5 pLVAD prior to as compared with after PCI of ULMCA for AMICS culprit lesion is associated with significant early survival. As previously described, patients supported after PCI appear to have very poor survival at 30 days. © 2017, Wiley Periodicals, Inc.

  10. Left atrial asynchrony and mechanical function in patients with mitral stenosis before and immediately after percutaneous balloon mitral valvuloplasty: a real time three-dimensional echocardiography study.

    PubMed

    Deng, Yan; Guo, Sheng-lan; Su, Hong-yue; Wang, Qian; Tan, Zhen; Wu, Ji; Zhang, Di

    2015-02-01

    This study evaluated the feasibility of assessing left atrium (LA) function and asynchrony in patients with rheumatic mitral stenosis (MS) before and immediately after percutaneous balloon mitral valvuloplasty (PBMV) by real time three-dimensional echocardiography (RT3DE). Thirty patients with rheumatic MS who underwent PBMV and 30 controls were enrolled. RT3DE was used to measure LA volume and function, the standard deviation of time to the minimal systolic volume divided into 16 segments, 12 segments, or 6 segments (Tmsv 16-SD, Tmsv 12-SD, Tmsv 6-SD), and the maximum differences (Tmsv 16-Dif, 12-Dif, 6-Dif) in RT3DE derived values in MS patients before and 2 days after PBMV were obtained and compared with those of normal controls. The associations between the LA asynchrony and heart volume, function, mitral valve area (MVA), maximum mitral valve gradient (MVGmax ), mean mitral valve gradient (MVGmean), and mean LA pressure (MLAP) were investigated. Left atrium asynchrony indexes were significantly larger, and LA function parameters were significantly lower in the MS group than in the controls (P < 0.05 for all). Of all the LA asynchrony indexes, LA Tmsv16-SD was most significantly correlated with the LA volume and function parameters, MVGmax , MVGmean , and MLAP (P < 0.05 for all). LA asynchrony indexes and LA volume significantly deceased, and LA function significantly increased post-PBMV (P < 0.05). Real time three-dimensional echocardiography is a reliable and reproducible method to quantify LA function and asynchrony. RT3DE revealed a significant, early improvement in LA function and asynchrony in MS patients after PBMV. © 2014, Wiley Periodicals, Inc.

  11. Percutaneous transvenous mitral commissurotomy in juvenile mitral stenosis.

    PubMed

    Adhikari, Chandra Mani; Malla, Rabi; Rajbhandari, Rajib; Shakya, Urmila; Sharma, Poonam; Shrestha, Nagma; Kc, Bishal; Limbu, Deepak; Kc, Man Bahadur

    2016-02-01

    Percutaneous transvenous mitral commissurotomy (PTMC) is a valid alternative to surgical therapy in selected patients with mitral stenosis. Juvenile mitral stenosis (JMS) varies uniquely from adult rheumatic heart disease (RHD). We aimed to evaluate the efficacy of PTMC in JMS patients. It was a single centre, retrospective study conducted between July 2013 to June 2015 in Shahid Gangalal National Heart Centre, Kathmandu, Nepal. Medical records of all consecutive patients aged less than 21 years who underwent PTMC were included. Mitral valve area (MVA), left atrial pressure and mitral regurgitation (MR) were compared pre and post procedure. During the study period 131 JMS patients underwent PTMC. Seventy (53.4%) were female and 61 (46.6%) were male. Among the 131 patients, 40 (30.5%) patients were below the age of 15 years. Patient age ranged between 9 to 20 years with the mean of 16.3±2.9 years. Electrocardiography (ECG) findings were normal sinus rhythm in 115 (87.7%) patients and atrial fibrillation in 16 (12.3%) patients. Left atrial size ranged from 2.9 to 6.1 cm with the mean of 4.5±0.6 cm. The mean MVA increased from 0.8±0.1 cm(2) to 1.6±0.2 following PTMC. Mean left atrial pressure decreased from their pre-PTMC state of 27.5±8.6 to 14.1±5.8 mmHg. Successful results were observed in 115 (87.7%) patients. Suboptimal MVA <1.5 cm(2) in 11 (8.4%) patients and post-procedure MR of more than moderate MR in 5 (3.8%) patients was the reason for unsuccessful PTMC. PTMC in JMS is safe and effective.

  12. Doppler echocardiographic myocardial stunning index predicts recovery of left ventricular systolic function after primary percutaneous coronary intervention.

    PubMed

    Sharif, Dawod; Matanis, Wisam; Sharif-Rasslan, Amal; Rosenschein, Uri

    2016-10-01

    Myocardial stunning is responsible for partially reversible left ventricular (LV) systolic dysfunction after successful primary percutaneous coronary intervention (PPCI) in patients with acute ST-elevation myocardial infarction (STEMI). To test the hypothesis that early coronary blood flow (CBF) to LV systolic function ratios, as an equivalent to LV stunning index (SI), predict recovery of LV systolic function after PPCI in patients with acute STEMI. Twenty-four patients with acute anterior STEMI who had successful PPCI were evaluated and compared to 96 control subjects. Transthoracic echocardiography with measurement of LV ejection fraction (EF), LV, and left anterior descending (LAD) coronary artery area wall-motion score index (WMSI) as well as Doppler sampling of LAD blood velocities, early after PPCI and 5 days later, were performed. SI was evaluated as the early ratio of CBF parameters in the LAD to LV systolic function parameters. Early SI-LVEF well predicted late LVEF (r=.51, P<.01) and the change in LVEF (r=.48, P<.017). Early SI-LVMSI predicted well late LVEF (r=.56, P<.006) and the change in LVEF (r=.46, P<.028). Early SI-LADWMSI predicted late LVEF (r=.44, P<.028). Other SI indices measured as other LAD-CBF to LV systolic function parameters were not predictive of late LV systolic function. LV stunning indices measured as early LAD flow to LVEF, LVWMSI, and LADWMSI ratios well predicted late LVEF and the change in LVEF. Thus, greater early coronary artery flow to LV systolic function parameter ratios predict a better improvement in late LV systolic function after PPCI. © 2016, Wiley Periodicals, Inc.

  13. Clinical impacts of inhibition of renin-angiotensin system in patients with acute ST-segment elevation myocardial infarction who underwent successful late percutaneous coronary intervention.

    PubMed

    Park, Hyukjin; Kim, Hyun Kuk; Jeong, Myung Ho; Cho, Jae Yeong; Lee, Ki Hong; Sim, Doo Sun; Yoon, Nam Sik; Yoon, Hyun Ju; Hong, Young Joon; Kim, Kye Hun; Park, Hyung Wook; Kim, Ju Han; Ahn, Youngkeun; Cho, Jeong Gwan; Park, Jong Chun; Kim, Young Jo; Cho, Myeong Chan; Kim, Chong Jim

    2017-01-01

    Successful percutaneous coronary intervention (PCI) of the occluded infarct-related artery (IRA) in latecomers may improve long-term survival mainly by reducing left ventricular remodeling. It is not clear whether inhibition of renin-angiotensin system (RAS) brings additional better clinical outcomes in this specific population subset. Between January 2008 and June 2013, 669 latecomer patients with acute ST-segment elevation myocardial infarction (STEMI) (66.2±12.1 years, 71.0% males) in Korea Acute Myocardial Infarction Registry (KAMIR) who underwent a successful PCI were enrolled. The study population underwent a successful PCI for a totally occluded IRA. They were divided into two groups according to whether they were prescribed RAS inhibitors at the time of discharge: group I (RAS inhibition, n=556), and group II (no RAS inhibition, n=113). During the one-year follow-up, major adverse cardiac events (MACE), which consist of cardiac death and myocardial infarction, occurred in 71 patients (10.6%). There were significantly reduced incidences of MACE in the group I (hazard ratio=0.34, 95% confidence interval 0.199-0.588, p=0.001). In subgroup analyses, RAS inhibition was beneficial in patients with male gender, history of hypertension or diabetes mellitus, and even in patients with left ventricular ejection fraction (LVEF) ≥40%. In the baseline and follow-up echocardiographic data, benefit in changes of LVEF and left ventricular end-systolic volume was noted in group I. In latecomers with STEMI, RAS inhibition improved long-term clinical outcomes after a successful PCI, even in patients with low risk who had relatively preserved LVEF. Copyright © 2016 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  14. Left ventricular systolic and diastolic function improve after acute myocardial infarction treated with acute percutaneous coronary intervention, but are not influenced by intracoronary injection of autologous mononuclear bone marrow cells: a 3 year serial echocardiographic sub-study of the randomized-controlled ASTAMI study.

    PubMed

    Beitnes, Jan Otto; Gjesdal, Ola; Lunde, Ketil; Solheim, Svein; Edvardsen, Thor; Arnesen, Harald; Forfang, Kolbjørn; Aakhus, Svend

    2011-02-01

    To clarify long-term changes in global, regional, and diastolic left ventricular (LV) function after intracoronary injection of autologous mononuclear bone marrow cells (mBMCs) in acute myocardial infarction (AMI). In the Autologous Stem cell Transplantation in Acute Myocardial Infarction (ASTAMI) study, 100 patients with anterior ST-elevation myocardial infarction and percutaneous coronary intervention on the left anterior descending artery (LAD) were randomized to receive intracoronary injection of mBMCs or not. Transthoracic echocardiography was performed at baseline, 3, 6, 12 months, and 3 years. Regional LV function was assessed by two-dimensional speckle-tracking echocardiography. From baseline to 3 years, LV ejection fraction changed from 45.7 to 47.5% in the mBMC group, and from 46.9 to 46.8% in the control group (P = 0.87 for difference in change over time between groups). Longitudinal strain in the LAD territory improved from -9.7 to -12.2% in the mBMC group and from -9.9 to -12.8% in the control group (P = 0.45). E/e' decreased from 14.7 to 12.9 in the mBMC group and from 14.8 to 11.9 in the control group (P = 0.31). There were no significant differences between groups in change of LV volumes, global systolic function, regional function, or diastolic function during 3 years follow-up. No differences between groups indicating beneficial effect of intracoronary mBMC injection could be identified. Both groups in ASTAMI experienced improvement of global, regional, and diastolic LV function after 3-6 months, with effects sustained at 3 years.

  15. Influence of manual thrombus aspiration on left ventricular diastolic function in patients with ST-segment elevation myocardial infarction treated with primary percutaneous coronary intervention.

    PubMed

    Ilić, Ivan; Stanković, Ivan; Vidaković, Radosav; Janićijević, Aleksandra; Cerović, Milivoje; Jovanović, Vladimir; Aleksić, Aleksandar; Obradović, Gojko; Nikolajević, Ivica; Kafedzić, Srdjan; Milicević, Dusan; Kusić, Jovana; Putniković, Biljana; Nesković, Aleksandar N

    2016-01-01

    Data on effects of thrombus aspiration on left ventricular diastolic function in ST-elevation myocardial infarction (STEMI) population are scarce. We sought to compare echocardiographic indices of the diastolic function and outcomes in STEMI patients treated with and without manual thrombus aspiration, in an academic, high-volume percutaneous coronary intervention (PCI) center. A total of 433 consecutive patients who underwent primary PCI in 2011-2012 were enrolled in the study. Patients were not eligible for the study if they already suffered a myocardial infarction, had been previously revascularized, received thrombolytics, presented with cardiogenic shock, had significant valvular disease, atrial fibrillation or had previously implanted pacemaker. Comprehensive echocardiogram was performed within 48 hours. During follow-up patients'status was assessed by an office visit or telephone interview. Patients treated with thrombus aspiration (TA+, n=216) had similar baseline characteristics as those without thrombus aspiration (TA-, n = 217). Groups had similar total ischemic time (319 ± 276 vs. 333 ± 372 min; p = 0.665), but TA+ group had higher maximum values of troponin I (39.5 ± 30.5 vs. 27.6 ± 26.9 ng/ml; p < 0.001). The echocardiography revealed similar left ventricular volumes and systolic function, but TA+ group had significantly higher incidence of E/e' > 15, as a marker of severe diastolic dysfunction' (TA+ 23.1% vs. TA- 15.2%; p = 0.050). During average follow-up of 14 ± 5 months, major adverse cardiac/cerebral events occurred at the similar rate (log rank p = 0.867). Thrombus aspiration is associated with a greater incidence of severe diastolic dysfunction in unselected STEMI patients treated with primary PCI, but it doesn't influence the incidence of major adverse cardiovascular events.

  16. Relationship of ischemic times and left atrial volume and function in patients with ST-segment elevation myocardial infarction treated with primary percutaneous coronary intervention.

    PubMed

    Ilic, Ivan; Stankovic, Ivan; Vidakovic, Radosav; Jovanovic, Vladimir; Vlahovic Stipac, Alja; Putnikovic, BiIjana; Neskovic, Aleksandar N

    2015-04-01

    Little is known about the impact of duration of ischemia on left atrial (LA) volumes and function during acute phase of myocardial infarction. We investigated the relationship of ischemic times, echocardiographic indices of diastolic function and LA volumes in patients with ST-segment elevation myocardial infarction (STEMI) treated with primary percutaneous coronary intervention (PCI). A total of 433 consecutive STEMI patients underwent echocardiographic examination within 48 h of primary PCI, including the measurement of LA volumes and the ratio of mitral peak velocity of early filling to early diastolic mitral annular velocity (E/e'). Time intervals from onset of chest pain to hospital admission and reperfusion were collected and magnitude of Troponin I release was used to assess infarct size. Patients with LA volume index (LAVI) ≥28 ml/m(2) had longer total ischemic time (410 ± 347 vs. 303 ± 314 min, p = 0.007) and higher E/e' ratio (15 ± 5 vs. 10 ± 3, p < 0.001) than those with LAVI <28 ml/m(2), while the indices of LA function were similar between the study groups (p > 0.05, for all). Significant correlation was found between E/e' and LA volumes at all stages of LA filling and contraction (r = 0.363-0.434; p < 0.001, for all) while total ischemic time along with E/e' and restrictive filling pattern remained independent predictor of LA enlargement. Increased LA volume is associated with longer ischemic times and may be a sensitive marker of increased left ventricular filling pressures in STEMI patients treated with primary PCI.

  17. Percutaneous coronary intervention in Thammasat University Hospital: the first three-year experience.

    PubMed

    Piyayotai, Dilok; Hutayanon, Pisit

    2010-12-01

    To study the results of percutaneous coronary intervention (PCI) and in-hospital outcomes in cardiac catheterization laboratory, Thammasat University Hospital since May, 2006 until April, 2009. This is the prospective, single-center study. The consecutive patients who underwent PCI in Thammasat University Hospital since May 2006 to April 2009 were recruited in the study. Clinical data, angiographic data, and in-hospital outcomes were analyzed and demonstrated. Six hundred and seventeen patients undergoing 755 PCI procedures were enrolled in the study. 62.70% were male and 37.30% were female. Mean age was 65.45 +/- 11.21 years (range 33-97 years) and 20.10% were more than 75 years old. The indications for PCI were non-ST segment-elevation acute coronary syndrome (NSTEACS) (41.72%), chronic stable angina (25.32%), acute ST segment elevation myocardial infarction (STEMI) (8.87%), staged PCI (15.76%). The other indications were heart failure, cardiomyopathy, post-cardiac arrest and etc. The procedure was single vessel PCI in 73.25% and multivessel PCI in 26.75% (double vessels PCI 24.64% and triple vessels PCI 2.11%). According to lesion locations, 45.21% were left anterior descending (LAD) artery lesions, 30.09% were right coronary artery (RCA) lesions, 23.28% were left circumflex (LCX) artery lesions, 1.19% were left main (LM) lesions and 0.24% were graft lesions. The overall angiographic success rate was 95.57%. During hospital stay the major adverse events developed as death in 0.93%, periprocedural myocardial infarction in 3.17%, emergency coronary artery bypass graft in 0.53%, and stroke in 0.26%. During the first three years of PCI experience in Thammasat University Hospital, the overall success rate was high with low in-hospital adverse outcomes.

  18. hsCRP and ET-1 expressions in patients with no-reflow phenomenon after Percutaneous Coronary Intervention.

    PubMed

    Liu, Min; Liang, Tian; Zhang, Peiying; Zhang, Qing; Lu, Lei; Wang, Zhongliang

    2017-01-01

    To explore hsCRP and ET-1 expressions in patients with no-reflow phenomenon after percutaneous coronary intervention (PCI). A total of 136 patients with single coronary artery disease receiving PCI were divided into a reflow group and a no-reflow group to compare the level use of ET-1 alone with combined level of ET-1 and hs-CRP in PCI regarding sensitivity, specificity, positive and negative predictive values and accuracy for postoperative no-reflow. The study was conducted between 2014-2016 at our hospital. Postoperative levels of ET-1 and hs-CRP in no-reflow group were significantly higher than those of reflow group (P<0.05). ET-1 level of reflow group peaked three hours after PCI and then declined. Serum level of hs-CRP decreased most obviously within three hours after PCI in reflow group and three hours - three days after PCI in no-reflow group. Left ventricular end-diastolic diameters of both groups after PCI were apparently lower than those before PCI, without significant inter-group difference (P>0.05). Left ventricular end-systolic diameters and left ventricular ejection fractions of both groups evidently increased after PCI, without significant inter-group differences either (P>0.05). Corrected TIMI frame count (CTFC) and wall motion score index of reflow group after PCI were significantly lower than those of no-reflow group (P<0.05). ET-1 level was positively correlated with CTFC (P<0.05). Multivariate linear regression showed hs-CRP was negatively correlated with the serum level (P<0.05) (r=-0.34). hsCRP and ET-1 levels significantly increased in patients with no-reflow phenomenon.

  19. Outcome and management of pacemaker-induced superior vena cava syndrome.

    PubMed

    Fu, Hai-Xia; Huang, Xin-Miao; Zhong, Li; Osborn, Michael J; Bjarnason, Haraldur; Mulpuru, Siva; Zhao, Xian-Xian; Friedman, Paul A; Cha, Yong-Mei

    2014-11-01

    We aimed to determine the long-term outcomes of percutaneous lead extraction and stent placement in patients with pacemaker-induced superior vena cava (SVC) syndrome. The study retrospectively screened patients who underwent lead extraction followed by central vein stent implantation at Mayo Clinic (Rochester, MN, USA), from January 2005 to December 2012, to identify the patients with pacemaker-induced SVC syndrome. Demographic, clinical, and follow-up characteristics of those patients were collected from electronic medical records. Six cases were identified. The mean (standard deviation) age was 56 (15) years (male, 67%). All patients had permanent dual-chamber pacemakers, with a mean 11-year history of pacemaker placement. The entire device system was explanted in five patients; one patient had a 21-year-old pacemaker lead that could not be removed. Eight stents were implanted in six patients: five patients had one stent, one patient had three. A new pacemaker system was reimplanted through the stented vein in five patients. Technical success was achieved in all patients, without any complication. Symptoms rapidly resolved in all patients after stent deployment. The mean follow-up duration was 48 months (range, 10-100 months). Three patients remained symptom free. Reintervention with percutaneous balloon venoplasty was successful in three patients with symptom recurrence. Percutaneous stent implantation after lead removal followed by reimplantation of leads is a feasible alternative therapy for pacemaker-induced SVC syndrome, although some cases may require repeat intervention. ©2014 Wiley Periodicals, Inc.

  20. [Results of the percutaneous retrograde embolization as the first choice in the treatment of varicocele].

    PubMed

    Piñera, J Gonzálvez; Fernández-Córdoba, M S; Anselmi, E Hernández; Mollá, E Juliá; Jiménez, M J Pedrosa; Cabañero, A G Blanco; Baró, A Palma

    2009-07-01

    There is evidence that early varicocele treatment decreases testicular damage. The minimally invasive techniques such as laparoscopic varicocelectomy, antegrade sclerotherapy and percutaneous retrograde embolisation, are acquiring greater significance in the treatment of this disease. Since 1994, a series of 51 children, aged 7-16 years (mean, 12.9 years), with left-sided varicocele grades 2 (47%) and 3 (53%) were treated in our institution by percutaneous retrograde embolisation using coils. The right basilica vein was the most widely used (70%) followed by the right femoral vein. Seven children (13.7%) had complications: perforation of internal spermatic vein was the most frequent and treated conservatively. No child presented hydrocele after radiological procedures. Embolisation was accomplished succesfully at the first attempt in 35 (68.6%) of the 51 children and in 45 (88.2%) after a second embolisation. The follow-up ranges from 7 months to 5 ? years (mean, 1.8 years). The patients were monitored with clinical and doppler ultrasound examination 3, 6 and 12 months after the treatment. Retrograde embolisation is a safe and efficient minimally invasive treatment for correcting varicoceles in children. We performed retrograde embolisation as first choice of varicocele treatment in children; a second embolisation or conventional surgery for primary failure or late recurrence should be considered.

  1. Surgical treatment for Ellis type 3 coronary perforation during percutaneous catheter intervention.

    PubMed

    Totsugawa, Toshinori; Kuinose, Masahiko; Yoshitaka, Hidenori; Katayama, Keijiro; Tsushima, Yoshimasa; Ishida, Atsuhisa; Chikazawa, Genta; Hiraoka, Arudo

    2012-01-01

    Coronary perforation (CP) is a rare, but sometimes lethal, complication of percutaneous catheter intervention (PCI). We reviewed surgically-treated cases of type 3 CP during PCI. From 2007 to 2010, 5 patients underwent surgical repair for type 3 CP (3 men, 2 women; mean age, 74 years). The mean number of diseased coronary branches was 2.6 and the mean SYNTAX score was 45. The target lesions were the left anterior descending artery in 4 cases and the right coronary artery in 1 case. Types of American Heart Association/American College of Cardiology classification were type B2 in only one case and type C in 4 cases. The causes of perforation were balloon inflation in 4 patients and rotational atherectomy in 1 patient. The in-hospital mortality rate was 20%. In the cases of CP associated with balloon inflation, coronary lacerations were so severe that re-bleeding occurred even if the covered stent could temporarily achieve hemostasis, and percutaneous cardiopulmonary support and emergency surgery were required. CP induced by balloon inflation tends to result in a serious condition compared with rotablator-induced CP. Surgery should be immediately performed even after covered stent implantation if there is any possibility of re-bleeding in the case of balloon-induced type 3 CP.

  2. Asynchronous slipped capital femoral epiphysis in a patient with a seizure disorder: case report and review of the literature.

    PubMed

    Patterson, Diana C; Price, Andrew E

    2018-05-01

    Debate remains about the appropriate treatment of the asymptomatic side following treatment of a unilateral slipped capital femoral epiphysis (SCFE). A 12-year-old boy with a seizure disorder presented with an unstable SCFE on the left hip following a seizure. He underwent percutaneous pinning of the left only. At 8 months postoperatively, he returned with an unstable slip of the right hip, again following a seizure. No literature discussing the treatment of patients with risk of SCFE and seizure disorders was identified. Further study may identify an increased incidence of contralateral slip following an initial slip in this population. If a greater risk exists, contralateral prophylactic fixation at time of index surgery may be indicated.

  3. Left Main Coronary Artery Obstruction by Dislodged Native-Valve Calculus after Transcatheter Aortic Valve Replacement

    PubMed Central

    Durmaz, Tahir; Keles, Telat; Aslan, Abdullah Nabi; Erdogan, Kemal Esref; Sari, Cenk; Bilen, Emine; Akcay, Murat; Bozkurt, Engin

    2014-01-01

    Transcatheter aortic valve replacement can be an effective, reliable treatment for severe aortic stenosis in surgically high-risk or ineligible patients. However, various sequelae like coronary artery obstruction can occur, not only in the long term, but also immediately after the procedure. We present the case of a 78-year-old woman whose left main coronary artery became obstructed with calculus 2 hours after the transfemoral implantation of an Edwards Sapien XT aortic valve. Despite percutaneous coronary intervention in that artery, the patient died. This case reminds us that early recognition of acute coronary obstruction and prompt intervention are crucial in patients with aortic stenosis who have undergone transcatheter aortic valve replacement. PMID:25120396

  4. Splenic abscess: report of six cases and review of the literature.

    PubMed

    Green, B T

    2001-01-01

    Splenic abscesses are rare but appear to be increasing in frequency. Recent advances in radiologic techniques have affected the diagnosis and management. The purpose of this study was to evaluate these effects. The medical records of one institution were retrospectively reviewed and six cases of splenic abscesses seen between 1989 and 1999 were identified. All patients had predisposing conditions with metastatic hematogenous infection in three and one each with trauma, immunodeficiency, and a contiguous site of infection. Fever was present in all patients with chills and vomiting in five and three patients, respectively. Left upper quadrant tenderness appeared in four patients and leukocytosis was found in every patient except one with the acquired immunodeficiency syndrome. Chest roentgenograms were abnormal in five patients with a left pleural effusion most common. Ultrasound revealed the defect in both patients it was utilized in and computed tomography was diagnostic in all cases. The causative organisms were anaerobes in two cases and Candida albicans, Streptococcus viridans, Escherichia coli, and Citrobacter freundii each present in one case. Radiology guided percutaneous drainage was attempted in four patients but was only successful in one. Splenectomy with antibiotics was curative in the remainder with a 100 per cent survival. These data suggest that percutaneous drainage may be appropriate for certain patients initially, but the high failure rate demonstrates that splenectomy remains the standard treatment.

  5. Percutaneous distraction lengthening in brachymetacarpia.

    PubMed

    Volpi, Alexander D; Fragomen, Austin T

    2011-08-08

    Brachymetacarpia is a condition manifesting a shortened metacarpal that is caused by early closure of the epiphyseal plate and believed to arise idiopathically. The correction for brachymetacarpia is usually for cosmetic reasons as brachymetacarpia does not impair function. The literature indicates several different approaches to lengthening digits, including single-stage lengthening and rapid distraction lengthening with a bone graft. However, gradual distraction is the preferred method due to excellent cosmetic outcomes and few postoperative complications. This article reports a case of brachymetacarpia treated with distraction lengthening using a minimally invasive, percutaneous approach. A 16-year-old girl presented with a shortened left ring finger and underwent surgery to correct the deformity. The left ring finger measured 12 mm shorter than her right ring finger; however, there was normal mobility at the joints. In the operating room, an external fixator was attached using 4 self-drilling, self-tapping pins through several 3-mm skin incisions. The total fixation time was 14 weeks; however, the achieved length of 12 mm was achieved 6 weeks postoperatively. The healing index of the fixation period was 81 days/cm. The postoperative course and fixation period were uneventful, with no complications except for 2 pin infections that were treated with oral antibiotics. The method of gradual distraction lengthening in this case successfully achieved the desired length and yielded an excellent cosmetic result. Copyright 2011, SLACK Incorporated.

  6. Percutaneous assist devices in acute myocardial infarction with cardiogenic shock: Review, meta-analysis

    PubMed Central

    Romeo, Francesco; Acconcia, Maria Cristina; Sergi, Domenico; Romeo, Alessia; Francioni, Simona; Chiarotti, Flavia; Caretta, Quintilio

    2016-01-01

    AIM: To assess the impact of percutaneous cardiac support in cardiogenic shock (CS) complicating acute myocardial infarction (AMI), treated with percutaneous coronary intervention. METHODS: We selected all of the studies published from January 1st, 1997 to May 15st, 2015 that compared the following percutaneous mechanical support in patients with CS due to AMI undergoing myocardial revascularization: (1) intra-aortic balloon pump (IABP) vs Medical therapy; (2) percutaneous left ventricular assist devices (PLVADs) vs IABP; (3) complete extracorporeal life support with extracorporeal membrane oxygenation (ECMO) plus IABP vs IABP alone; and (4) ECMO plus IABP vs ECMO alone, in patients with AMI and CS undergoing myocardial revascularization. We evaluated the impact of the support devices on primary and secondary endpoints. Primary endpoint was the inhospital mortality due to any cause during the same hospital stay and secondary endpoint late mortality at 6-12 mo of follow-up. RESULTS: One thousand two hundred and seventy-two studies met the initial screening criteria. After detailed review, only 30 were selected. There were 6 eligible randomized controlled trials and 24 eligible observational studies totaling 15799 patients. We found that the inhospital mortality was: (1) significantly higher with IABP support vs medical therapy (RR = +15%, P = 0.0002); (2) was higher, although not significantly, with PLVADs compared to IABP (RR = +14%, P = 0.21); and (3) significantly lower in patients treated with ECMO plus IABP vs IABP (RR = -44%, P = 0.0008) or ECMO (RR = -20%, P = 0.006) alone. In addition, Trial Sequential Analysis showed that in the comparison of IABP vs medical therapy, the sample size was adequate to demonstrate a significant increase in risk due to IABP. CONCLUSION: Inhospital mortality was significantly higher with IABP vs medical therapy. PLVADs did not reduce early mortality. ECMO plus IABP significantly reduced inhospital mortality compared to IABP. PMID:26839661

  7. Hubble Space Telescope Deploy, Eastern Cuba, Haiti

    NASA Image and Video Library

    1990-04-29

    A close up deploy view of the Hubble Space Telescope on the end of the space shuttle remote manipulator system (RMS) with Eastern Cuba, (20.0N, 74.0W) seen on the left side of the telescope and northern Haiti seen on the right side of the telescope. The light colored blue feature in the water north of Haiti is the shallow waters of the Caicos Bank.

  8. Nanoracks CUBESAT launcher operations

    NASA Image and Video Library

    2014-08-19

    ISS040-E-102490 (19 Aug. 2014) --- In the grasp of the Japanese robotic arm, the CubeSat deployer releases a pair of NanoRacks CubeSat miniature satellites. The Planet Labs Dove satellites that were carried to the International Space Station aboard the Orbital Sciences Cygnus commercial cargo craft are being deployed between Aug. 19 and Aug. 25. A section of the station solar array wings is at left.

  9. Nanoracks CUBESAT launcher

    NASA Image and Video Library

    2014-08-20

    ISS040-E-102420 (20 Aug. 2014) --- In the grasp of the Japanese robotic arm, the CubeSat deployer releases a pair of NanoRacks CubeSat miniature satellites. The Planet Labs Dove satellites that were carried to the International Space Station aboard the Orbital Sciences Cygnus commercial cargo craft are being deployed between Aug. 19 and Aug. 25. A section of the station solar array wings is at left.

  10. Nanoracks CUBESAT launcher

    NASA Image and Video Library

    2014-08-20

    ISS040-E-102425 (20 Aug. 2014) --- In the grasp of the Japanese robotic arm, the CubeSat deployer releases a pair of NanoRacks CubeSat miniature satellites. The Planet Labs Dove satellites that were carried to the International Space Station aboard the Orbital Sciences Cygnus commercial cargo craft are being deployed between Aug. 19 and Aug. 25. A section of the station solar array wings is at left.

  11. Technical feasibility and revision efficacy of the sequential deployment of endoscopic bilateral side-by-side metal stents for malignant hilar biliary strictures: a multicenter prospective study.

    PubMed

    Lee, Tae Hoon; Park, Do Hyun; Lee, Sang Soo; Choi, Hyun Jong; Lee, Jun Kyu; Kim, Tae Hyeon; Kim, Jong Hyeok; Jeong, Seok; Park, Sang-Heum; Moon, Jong Ho

    2013-02-01

    Theoretically, the side-by-side bilateral placement of metal stents may be technically easier than stent-in-stent bilateral placement in stent revision. However, side-by-side placement can be technically challenging, as the deployment of the first stent can preclude the passage of the second stent. We explored the technical feasibility and revision efficacy of endoscopic bilateral side-by-side stent placement for malignant hilar biliary strictures. Forty-four patients with Bismuth type II or higher malignant hilar biliary strictures were enrolled in seven academic tertiary referral centers. Endoscopic placement of side-by-side bilateral metal stents with 7F thin delivery shaft was performed. The outcome measurements were the technical and functional success, adverse events, endoscopic revision success rate, and stent patency. Overall, the technical and functional success rates were 91 % (40/44), and 98 % (39/40), respectively. Two of the failed patients were converted successfully with subsequent contralateral stent-in-stent placement, and the other patients underwent percutaneous intervention. Early stent-related adverse events occurred in 10 %. The endoscopic revision rate due to stent malfunction during follow-up (median: 180 days) was 45 % (18/40; tumor ingrowth in 4 and in-stent sludge impaction/stone formation in 14 patients). The endoscopic revision success rate was 92 % (12/13). Five patients with comorbidity underwent initial percutaneous intervention. The median survival and stent patency periods were 180 and 157 days, respectively. The sequential placement of a metal stent with a 7F thin delivery shaft in bilateral side-by-side procedures may be feasible and effective for malignant hilar biliary strictures and for endoscopic stent revision.

  12. Percutaneous Endovascular Treatment of Hepatic Artery Stenosis in Adult and Pediatric Patients After Liver Transplantation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maruzzelli, Luigi; Miraglia, Roberto, E-mail: rmiraglia@ismett.edu; Caruso, Settimo

    2010-12-15

    The purpose of this study was to evaluate the efficacy of percutaneous endovascular techniques for the treatment of hepatic artery stenosis (HAS) occurring after liver transplantation (LT) in adult and pediatrics patients. From February 2003 to March 2009, 25 patients (15 adults and 10 children) whose developed HAS after LT were referred to our interventional radiology unit. Technical success was achieved in 96% (24 of 25) of patients. Percutaneous transluminal angioplasty (PTA) was performed in 13 patients (7 children), and stenting was performed in 11 patients (2 children). After the procedure, all patients were followed-up with liver function tests, Dopplermore » ultrasound, and/or computed tomography. Mean follow-up was 15.8 months (range 5 days to 58 months). Acute hepatic artery thrombosis occurred immediately after stent deployment in 2 patients and was successfully treated with local thrombolysis. One patient developed severe HA spasm, which reverted after 24 h. After the procedure, mean trans-stenotic pressure gradient decreased from 30.5 to 6.2 mmHg. Kaplan-Meyer curve of HA primary patency was 77% at 1 and 2 years. During the follow-up period, 5 patients (20%) had recurrent stenosis, and 2 patients (8.3%) had late thrombosis. Two of 7 patients with stenosis/thrombosis underwent surgical revascularization (n = 1) and liver retransplantation (n = 1). Six (25%) patients died during follow-up, but overall mortality was not significantly different when comparing patients having patent hepatic arteries with those having recurrent stenosis/thrombosis. There were no significant differences in recurrent stenosis/thrombosis and mortality comparing patients treated by PTA versus stenting and comparing adult versus pediatric status. Percutaneous interventional treatment of HAS in LT recipients is safe and effective and decreases the need for surgical revascularization and liver retransplantation. However, the beneficial effects for survival are not clear, probably because the clinical complexity of many of these cases.« less

  13. Percutaneous pulmonary valve implantation for free pulmonary regurgitation following conduit-free surgery of the right ventricular outflow tract.

    PubMed

    Cools, Bjorn; Brown, Stephen C; Heying, Ruth; Jansen, Katrijn; Boshoff, Derize E; Budts, Werner; Gewillig, Marc

    2015-01-01

    Pulmonary regurgitation (PR) following surgery of the right ventricular outflow tract (RVOT) is not innocent and leads to significant right heart dysfunction over time. Recent studies have demonstrated that percutaneous valves can be implanted in conduit free outflow tracts with good outcomes. To evaluate in patients with severe PR--anticipated to require future pulmonary valve replacement--the feasibility and safety of pre-stenting dilated non-stenotic patched conduit-free right ventricular outflow tracts before excessive dilation occurs, followed by percutaneous pulmonary valve implantation (PPVI). Twenty seven patients were evaluated, but only 23 were deemed suitable based on the presence of an adequate retention zone ≤ 24 mm defined by semi-compliant balloon interrogation of the RVOT. A 2 step procedure was performed: first the landing zone was prepared by deploying a bare stent, followed 2 months later by valve implantation. RVOT pre-stenting with an open cell bare metal stent (Andrastent XXL range) was performed at a median age of 13.0 years (range: 6.0-44.9) with a median weight of 44.3 kg (range: 20.0-88.0). Ninety six percent (22/23) of patients proceeded to PPVI a median of 2.4 months (range: 1.4-3.4) after initial pre-stent placement. Twenty one Melody valves and one 26 mm Edwards SAPIEN™ valve were implanted. Complications consisted of embolization of prestent (n = 1), scrunching (n = 4) and mild stent dislocation (n = 2). During follow-up, no stent fractures were observed and right ventricular dimensions decreased significantly. Post-surgical conduit-free non-stenotic RVOT with free pulmonary regurgitation can be treated percutaneously with a valved stent if anatomical (predominantly size) criteria are met. In experienced hands, the technique is feasible with low morbidity. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  14. Laughter-induced left bundle branch block.

    PubMed

    Chow, Grant V; Desai, Dipan; Spragg, David D; Zakaria, Sammy

    2012-10-01

    We present the case of a patient with ischemic heart disease and intermittent left bundle branch block, reproducibly induced by laughter. Following treatment of ischemia with successful deployment of a drug-eluting stent, no further episodes of inducible LBBB were seen. Transient ischemia, exacerbated by elevated intrathoracic pressure during laughter, may have contributed to onset of this phenomenon. © 2012 Wiley Periodicals, Inc.

  15. Spontaneous splenic rupture in infectious mononucleosis: conservative management with gradual percutaneous drainage of a subcapsular hematoma.

    PubMed

    Schwarz, M; Zaidenstein, L; Freud, E; Neuman, M; Ziv, N; Kornreich, L; Zer, M

    1999-01-01

    Spontaneous splenic rupture (SSR) is a rare but potentially lethal complication of infectious mononucleosis (IM). Because the inflamed spleen is usually enlarged, congested, and friable, emergency splenectomy is recommended. We describe the conservative management of a SSR in a 16-year-old boy with IM. A pigtail catheter was inserted under ultrasonographic guidance and left in place for 36 h. This allowed the successful evacuation of the hematoma without compromising the splenic parenchyma.

  16. Does three-dimensional transesophageal echocardiography provide incremental value in percutaneous closure of ascending aortic pseudoaneurysm?

    PubMed

    Elkaryoni, Ahmed; Hsiung, Ming C; Arisha, Mohammed J; Ahmad, Amier; Nanda, Navin C; Mohamed, Ahmed H; Attia, Doaa; Sachdeva, Ankush; Singh, Lovepreet; Yin, Wei-Hsian

    2017-07-01

    Ascending aortic pseudoaneurysms (AO PSAs), if left untreated, are complicated by a high rate of rupture resulting in significant morbidity and mortality. New transcatheter modalities have emerged as acceptable surgical alternatives for their management. We present a case of an ascending aortic PSA in which intraoperative two- and three-dimensional transesophageal echocardiography (2DTEE and 3DTEE) provided a comprehensive assessment of the PSA in pre- and postclosure settings. © 2017, Wiley Periodicals, Inc.

  17. How should I treat a patient to remove a fractured jailed side branch wire?

    PubMed

    Owens, Colum G; Spence, Mark S

    2011-08-01

    A 53-year-old female was sent for diagnostic angiography after successful reperfusion therapy for an anterior ST-elevation myocardial infarct. The culprit lesion was a LAD/D1 bifurcation stenosis. Coronary angiography, intravascular ultrasound. Left anterior descending artery/first diagonal artery bifurcation stenosis, fractured jailed side branch wire. Provisional stenting strategy for bifurcation stenosis. Consideration of surgical and percutaneous options to retrieve fractured, jailed, side branch wire. Wire and balloon catheter wrap technique for retrieval of fractured wire.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahmadi, Ramazan-Ali; Schillinger, Martin; Haumer, Markus

    Endarterectomy is currently the preferred treatment for severe carotid stenosis. The technique of eversion endarterectomy allows correction of severe vessel elongation and kinking. The latter is generally believed to be a relative contraindication for endovascular stent placement. We report successful percutaneous transluminal angioplasty and stenting of a left internal carotid artery with high-grade stenosis and severe kinking which was not amenable to endarterectomy because of the distal location of the stenosis. Advanced stent technology with flexible materials makes endovascular treatment of carotid stenosis feasible even in cases of kinking.

  19. Left heart bypass support with the Rotaflow Centrifugal Pump® as a bridge to decision and recovery in an adult.

    PubMed

    Kashiwa, Koichi; Nishimura, Takashi; Saito, Aya; Kubo, Hitoshi; Fukaya, Aoi; Tamai, Hisayoshi; Yambe, Tomoyuki; Kyo, Shunei; Ono, Minoru

    2012-06-01

    Since left heart bypass or biventricular circulatory assist with an extracorporeal centrifugal pump as a bridge to decision or recovery sometimes requires long-time support, the long-term durability of extracorporeal centrifugal pumps is crucial. The Rotaflow Centrifugal Pump(®) (MAQUET Cardiopulmonary AG, Hirrlingen, Germany) is one of the centrifugal pumps available for long-term use in Japan. However, there have been few reports of left heart bypass or biventricular circulatory support over the mid-term. This is a case report of left heart bypass support with the Rotaflow Centrifugal Pump(®) as a bridge to decision and recovery for an adult patient who could not be weaned from cardiopulmonary bypass and percutaneous cardiopulmonary support after cardiac surgery. We could confirm that the patient's consciousness level was normal; however, the patient could not be weaned from the left heart bypass support lasting 1 month. Therefore, the circulatory assist device was switched to the extracorporeal Nipro ventricular assist device (VAD). This time, left heart bypass support could be maintained for 30 days using a single Rotaflow Centrifugal Pump(®). There were no signs of hemolysis during left heart bypass support. The Rotaflow Centrifugal Pump(®) itself may be used as a device for a bridge to decision or recovery before using a VAD in cardiogenic shock patients.

  20. STS-31 Hubble Space Telescope (HST) pre-deployment procedures aboard OV-103

    NASA Image and Video Library

    1990-04-24

    During STS-31, the Hubble Space Telescope (HST) grappled by the remote manipulator system (RMS) end effector is held in appendage deploy position above Discovery, Orbiter Vehicle (OV) 103. The solar array (SA) bistem cassette has been released from its latch fittings. The bistem spreader bars begin to unfurl the SA wing. The secondary deployment mechanism (SDM) handle is visible at the SA end. Stowed against either side of the HST System Support Module (SSM) forward shell are the high-gain antennae (HGA). Puerto Rico and the Dominican Republic are recognizable at the left of the frame.

  1. Nanoracks CUBESAT launcher

    NASA Image and Video Library

    2014-08-20

    ISS040-E-102410 (20 Aug. 2014) --- In the grasp of the Japanese robotic arm, the CubeSat deployer is about to release a pair of NanoRacks CubeSat miniature satellites. The Planet Labs Dove satellites that were carried to the International Space Station aboard the Orbital Sciences Cygnus commercial cargo craft are being deployed between Aug. 19 and Aug. 25. A section of the station solar array wings is at left.

  2. The modern history and evolution of percutaneous nephrolithotomy.

    PubMed

    Patel, Sutchin R; Nakada, Stephen Y

    2015-02-01

    Serendipity, innovative physicians, evolving techniques for renal access, and improvements in equipment and radiology led to the evolution of percutaneous nephrolithotomy (PCNL). We searched urology texts and the literature for sources pertaining to the history and development of PCNL. In 1941, Rupel and Brown performed the first nephroscopy when a rigid cystoscope was passed into the kidney following open surgery. Willard Goodwin, in 1955, while trying to perform a renal arteriogram, placed a needle into the collecting system of a hydronephrotic kidney and performed the first antegrade nephrostogram. He left a tube to drain the kidney, thereby placing the first nephrostomy tube. By 1976, Fernström and Johansson were the first to describe a technique for extracting renal calculi through a percutaneous nephrostomy under radiological control. In 1978, Arthur Smith, would describe the first antegrade stent placement when he introduced a Gibbons stent through a percutaneous nephrostomy in a patient with a reimplanted ureter. Dr. Smith would coin the term "endourology" to describe closed, controlled manipulation of the genitourinary tract. His collaboration with Kurt Amplatz, an interventional radiologist and medical inventor, would lead to numerous innovations that would further advance PCNL. In the 1980s the process of renal access and tract dilation was improved upon and the use of a rigid cystoscope was replaced by offset nephroscopes with a large straight working channel. Radiographic innovations, including improvements in fluoroscopy would further aid in renal access. The development of various lithotripsy devices and the introduction of the holmium laser improved the efficiency of stone fragmentation and clearance. The increased clinical experience and utilization of PCNL would lead to the characterization of stone-free rates and complications for the procedure. Serendipity, innovations in renal access, optics, radiology, and improvements in lithotripsy all contributed to the modern day PCNL.

  3. Outcome of Percutaneous Release of Tennis Elbow: A Non-Randomized Controlled Trial Study.

    PubMed

    Panthi, Sagar; Khatri, Kishor; Kharel, Krishna; Byanjankar, Subin; Shrestha, Rahul; Sharma, Jay R; Vaishya, Raju; Agarwal, Amit Kumar; Vijay, Vipul

    2017-01-02

    Tennis elbow is a common disorder of the upper extremity. It can be treated conservatively in the majority of patients, but some resistant cases eventually can be treated by percutaneous release with good functional outcome. This non-randomized control trial was conducted at the Department of Orthopaedics Surgery in a tertiary care hospital from July 2015 to June 2016 on 50 patients who underwent percutaneous release of the common extensor origin using an 18 gauge hypodermic needle. These patients did not respond to conservative treatment including rest, nonsteroidal anti-inflammatory drugs (NSAIDS) and local steroid injections. The outcome was graded as Excellent, Good, Fair, and Poor. Fifty patients (50 elbows) were included in the study. Thirty-two patients were female (64%), and 18 were male (36%). The right side was affected in 37 patients (74%) and left side in 13 (26%). The time taken to achieve a completely pain-free elbow ranged from one day to two months (average of 26.2 days). Those who did not achieve a pain-free elbow had a residual pain of 1.5 to six on the visual analogue scale (VAS) (average 2.32). Excellent outcome was noticed in 24 patients (48%); Good result in eight patients (36% ); Fair in four patients (eight percent) and Poor in four patients (eight percent). Tennis elbow probably results from the degenerative tear of the common extensor origin, and a percutaneous tenotomy using an 18 gauge hypodermic needle is a simple, safe, patient-friendly, efficient, and easily reproducible method of treating tennis elbow in those who are resistant to conservative treatment, and it can be done as an outpatient procedure.

  4. Outcome of Percutaneous Release of Tennis Elbow: A Non-Randomized Controlled Trial Study

    PubMed Central

    Khatri, Kishor; Kharel, Krishna; Byanjankar, Subin; Shrestha, Rahul; Sharma, Jay R; Vaishya, Raju; Agarwal, Amit kumar; Vijay, Vipul

    2017-01-01

    Background Tennis elbow is a common disorder of the upper extremity. It can be treated conservatively in the majority of patients, but some resistant cases eventually can be treated by percutaneous release with good functional outcome. Materials and methods This non-randomized control trial was conducted at the Department of Orthopaedics Surgery in a tertiary care hospital from July 2015 to June 2016 on 50 patients who underwent percutaneous release of the common extensor origin using an 18 gauge hypodermic needle. These patients did not respond to conservative treatment including rest, nonsteroidal anti-inflammatory drugs (NSAIDS) and local steroid injections. The outcome was graded as Excellent, Good, Fair, and Poor. Results Fifty patients (50 elbows) were included in the study. Thirty-two patients were female (64%), and 18 were male (36%). The right side was affected in 37 patients (74%) and left side in 13 (26%). The time taken to achieve a completely pain-free elbow ranged from one day to two months (average of 26.2 days). Those who did not achieve a pain-free elbow had a residual pain of 1.5 to six on the visual analogue scale (VAS) (average 2.32). Excellent outcome was noticed in 24 patients (48%); Good result in eight patients (36% ); Fair in four patients (eight percent) and Poor in four patients (eight percent). Conclusion Tennis elbow probably results from the degenerative tear of the common extensor origin, and a percutaneous tenotomy using an 18 gauge hypodermic needle is a simple, safe, patient-friendly, efficient, and easily reproducible method of treating tennis elbow in those who are resistant to conservative treatment, and it can be done as an outpatient procedure. PMID:28168130

  5. Bronchobiliary Fistula Treated by Self-expanding ePTFE-Covered Nitinol Stent-Graft

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gandini, Roberto; Konda, Daniel; Tisone, Giuseppe

    A 71-year-old man, who had undergone right hepatectomy extended to the caudate lobe with terminolateral Roux-en-Y left hepatojejunostomy for a Klatskin tumor, developed bilioptysis 3 weeks postoperatively due to bronchobiliary fistula. Percutaneous transhepatic cholangiography revealed a non-dilated biliary system with contrast medium extravasation to the right subphrenic space through a resected anomalous right posterior segmental duct. After initial unsuccessful internal-external biliary drainage, the fistula was sealed with a VIATORR covered self-expanding nitinol stent-graft placed with its distal uncovered region in the hepatojejunal anastomosis and the proximal ePTFE-lined region in the left hepatic duct. A 10-month follow-up revealed no recurrence ofmore » bilioptysis and confirmed the complete exclusion of the bronchobiliary fistula.« less

  6. TandemHeart as a Bridge to Recovery in Legionella Myocarditis.

    PubMed

    Briceño, David F; Fernando, Rajeev R; Nathan, Sriram; Loyalka, Pranav; Kar, Biswajit; Gregoric, Igor D

    2015-08-01

    Legionnaires' disease is the designation for pneumonia caused by the Legionella species. Among the rare extrapulmonary manifestations, cardiac involvement is most prevalent, in the forms of myocarditis, pericarditis, postcardiotomy syndrome, and prosthetic valve endocarditis. Mechanical circulatory support has proved to be a safe and effective bridge to myocardial recovery in patients with acute fulminant myocarditis; however, to our knowledge, this support has not been used in infectious myocarditis specifically related to Legionellosis. We describe a case of Legionella myocarditis associated with acute left ventricular dysfunction and repolarization abnormalities in a 48-year-old man. The patient fully recovered after left ventricular unloading with use of a TandemHeart percutaneous ventricular assist device. In addition, we review the English-language medical literature on Legionella myocarditis and focus on cardiac outcomes.

  7. Percutaneous Treatment of an Infected Aneurysmal Sac Secondary to Aortoesophageal Fistula with a History of Stent-Graft Treatment for Thoracic Aortic Aneurysm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Numan, Furuzan, E-mail: drfgulsen@yahoo.com; Gulsen, Fatih; Cantasdemir, Murat

    2012-06-15

    A 68-year-old man who was subjected to stent-grafting of a descending thoracic aortic aneurysm (TAA) 4 months previously was admitted to our hospital with constitutional symptoms, including high fever, sweating, nausea, vomiting, weight loss, and backache. An infected aneurysmal sac was suspected based on computed tomography (CT) findings, and an aortoesophageal fistula (AEF) was identified during esophagoscopy. CT-guided aspiration was performed using a 20-G Chiba needle, confirming the presence of infection. For treatment of the infected aneurysmal sac, CT-guided percutaneous catheter drainage in a prone position was performed under general anesthesia with left endobronchial intubation. Drainage catheter insertion was successfullymore » performed using the Seldinger technique, which is not a standard treatment of an infected aneurysmal sac. Improvement in the patient's clinical condition was observed at follow-ups, and CT showed total regression of the collection in the aneurysmal sac.« less

  8. Effectiveness of Percutaneous Balloon Mitral Valvuloplasty for Rheumatic Mitral Stenosis with Mild to Severe Mitral Regurgitation

    PubMed Central

    Lu, LinXiang; Hong, Lang; Fang, Jun; Chen, LiangLong

    2016-01-01

    This study is designed to test whether percutaneous balloon mitral valvuloplasty (PBMV) is effective for rheumatic mitral stenosis in Chinese patients with moderate to severe mitral regurgitation. Fifty-six patients with rheumatic mitral valve stenosis were divided into the mild, moderate, and severe regurgitation groups. Cardiac ultrasonography was measured before and 1 to 2 days after PBMV. Following PBMV, the mitral orifice was enlarged, and the left atrial diameter was reduced in the 3 patient groups. The enlargement of the mitral orifice in the mild regurgitation group was greater than that observed in the moderate and severe regurgitation groups. The size of the regurgitation area increased in the mild regurgitation group and decreased in the moderate and severe regurgitation groups, with the decrease in the severe regurgitation group being greater than that in the moderate regurgitation group. Therefore, PBMV is effective for treating rheumatic mitral stenosis in Chinese patients with mild to severe mitral regurgitation. PMID:27034933

  9. Coronary blood flow during percutaneous hemopump in patients at high risk for angioplasty

    NASA Astrophysics Data System (ADS)

    Geschwind, Herbert J.; Dubois-Rande, Jean Luc; Dupouy, Patrick J.; Larrazet, Fabrice S.; Kvasnicka, Jan; El-Ghalid, Ahmed; Deleuze, Philippe; Loisance, Daniel

    1995-05-01

    Hemopump is a ventricular assist device which is aimed at improving the management of high- risk patients for PTCA. The aim of the study was to access coronary blood flow velocity during hemopump. The hemopump was inserted percutaneously into the femoral artery. Coronary blood flow was measured with a 12 MHz Doppler-tipped guidewire proximal and distal to the stenosis before, during and after PTCA. Coronary vascular reserve was assessed by intracoronary 12 mg bolus injection of Papaverine. Collateral flow was assessed during balloon occlusion by inverted velocity signals below baseline. Eight patients aged 59 +/- 11 yrs, with unstable angina, a last patent vessel and/or major left ventricular dysfunction (EF < 0.20) had hemopump during PTCA of stenosis (86 +/- 14%) of the LAD (n equals 4) or the LCX (n equals 4). Collateral flow was slightly increased (+25 +/- 18%) by the Hemopump. Hemopump did not strongly affect coronary flow velocity, did not significantly increase collateral flow and increased slightly coronary vascular reserve.

  10. Percutaneous nephrolithotomy for complete staghorn renal stones.

    PubMed

    Koko, Abdelmoniem H; Onuora, Vincent C; Al-Turkey, Mohamamed A; Al Moss, Mohammed; Meabed, Ahmed H; Al Jawani, Nasser A

    2007-03-01

    To evaluate the effectiveness of percutaneous nephrolithotomy (PNL) in the management of patients with complete staghorn stones, a retrospective study was conducted on 110 patients at the Riyadh Medical Complex, Riyadh, Kingdom of Saudi Arabia. The study was performed between September 1990 and September 1999. 144 procedures were performed on 119 renal units including 22 units (18.5%) that needed more than one sitting. Of them, 85 units (71.4%) were completely cleared after PNL and 11 units (9.2%) were left with insignificant residual fragments (< 4 mm). This gives a success rate of 78.6% for PNL as a monotherapy. Twelve patients with significant residual fragments required Extracorporal Shock Wave Lithotripsy (SWL) in addition to PNL. The overall success rate after PNL and SWL in 108 renal units was 89.4%. We found PNL useful in the management of patients with complete staghorn stones, either as monotherapy or in combination with SWL. It was associated with little morbidity and the procedure can be instituted even in centers with limited facilities.

  11. Coronary intervention in anomalous origin of the right coronary artery (ARCA) from the left sinus of valsalva (LSOV): a single center experience.

    PubMed

    Uthayakumaran, Kalaichelvan; Subban, Vijayakumar; Lakshmanan, Anitha; Pakshirajan, Balaji; Solirajaram, Ramkumar; Krishnamoorthy, Jaishankar; Janakiraman, Ezhilan; Pandurangi, Ulhas M; Kalidoss, Latchumanadhas; Sankaradas, Mullasari Ajit

    2014-01-01

    To assess the technical challenges in percutaneous coronary intervention of Anomalous right coronary artery arising from the left sinus of valsalva. Between year 2008 and 2012, a total of 17 patients underwent PCI for an angiographically significant lesion in the right coronary artery of an anomalous origin in the LSOV. Their procedure details such as usage of catheters, radiation time, amount of contrast used were assessed. A total of 17 patients with anomalous right coronary artery underwent PCI during the above mentioned period. 8 patients had type A origin, 3 had type B origin and the remaining 6 had type C origin. Type A origin RCA were successfully cannulated in 6 patients with Judkins left 5.0 and in 2 patients using Judkins left 4.0. Extra back up (EBU) 3.5 were doing well in 2 patients of Type B origin and the remaining one patient was successfully cannulated using Judkins left 4.0. In type C origin 4 patients had successful cannulation with Amplatz Left 1.0, 1 patient with Amplatz Left 2.0 and 1 patient with Judkins left 4.0. The mean fluoroscopic time was 20.7 min and amount of contrast used was 210 ml. PCI of anomalous RCA origin from LSOV requires appropriate guide catheter selection according to the anatomy of origin for successful cannulation and to reduce the contrast usage and radiation exposure. Copyright © 2014. Published by Elsevier B.V.

  12. Mechanism and Implications of the Tricuspid Regurgitation: From the Pathophysiology to the Current and Future Therapeutic Options.

    PubMed

    Mangieri, Antonio; Montalto, Claudio; Pagnesi, Matteo; Jabbour, Richard J; Rodés-Cabau, Josep; Moat, Neil; Colombo, Antonio; Latib, Azeem

    2017-07-01

    The tricuspid valve was virtually ignored for a long time in the past. However, significant tricuspid regurgitation (TR) often accompanies left-side heart valve pathology and does not always reverse with its correction. If left untreated, TR can progress and result in progressive right ventricular failure. Current guideline recommendations still hold minor differences. Nevertheless, there is a consensus to operate on patients with severe TR undergoing left-sided valve surgery (class I) or those with mild to moderate TR with a dilated annulus (≥40 or ≥21 mm 2 , Class IIa). However, in case of the primary TR, surgical options is limited by a relatively high risk of mortality and morbidity. For these patients, new percutaneous approaches are becoming available but no long-term data are still available. In this review, we provide a comprehensive overview of the epidemiological and pathophysiological aspects of TR, and the current and future directions of therapy. © 2017 American Heart Association, Inc.

  13. A case report on buccal mucosa graft for upper ureteral stricture repair.

    PubMed

    Sabale, Vilas Pandurang; Thakur, Naveen; Kankalia, Sharad Kumar; Satav, Vikram Pramod

    2016-01-01

    Management of ureteric stricture especially long length upper one-third poses a challenging job for most urologists. With the successful use of buccal mucosa graft (BMG) for stricture urethra leads the foundation for its use in ureteric stricture also. A 35-year-old male diagnosedcase of left upper ureteric stricture, postureteroscopy with left percutaneous nephrostomy (PCN) in situ . Cysto-retrograde pyelography and nephrostogram done simultaneously suggestive of left upper ureteric stricture of 3 cm at L3 level. On exploration, diseased ureteral segment exposed, BMG harvested and sutured as onlay patch graft with supportive omental wrap. The treatment choice for upper ureteric long length stricture is inferior nephropexy, autotransplantation, or bowel interposition. With PCN in situ , inferior nephropexy becomes technically difficult, other two are morbid procedures. Use of BMG in this situation is technically better choice with all the advantages of buccal mucosa. Onlay BMG for ureteral stricture is technically easy, less morbid procedure and can be important choice in future.

  14. A case of recurrent cholangitis after bile duct injury during laparoscopic cholecystectomy: value of scintigraphy with Tc-99m GSA and hepatobiliary scintigraphy for indication of lobectomy.

    PubMed

    Nishiguchi, S; Shiomi, S; Sasaki, N; Iwata, Y; Tanaka, H; Kubo, S; Hirohashi, K; Ochi, H

    2000-10-01

    A 39-year-old woman with acute cholecystitis and gallstones underwent laparoscopic cholecystectomy. She suffered from recurrent episodes of cholangitis due to injury of the major bile ducts during laparoscopic cholecystectomy. Hepatobiliary scintigraphy with Tc-99m Sn-N-pyridoxyl-5-methyltryptophan was performed. Although normal bile excretion was found from the left hepatic duct to the percutaneous transhepatic biliary drainage (PTBD) tube, excretion from the right hepatic lobe was prolonged. Scintigraphy with Tc-99m diethylenetriaminepentaacetic acid-galactosyl human serum albumin demonstrated atrophy of the right hepatic lobe and enlargement of the left hepatic lobe. Cholangiography via the PTBD tube revealed complete obstruction of the left hepatico-jejunal anastomosis and could not enhance the right intrahepatic bile duct. A right hepatic lobectomy was performed because of the atrophy, glissonitis and the absence of an appropriate bile duct for reconstruction. Postoperatively she was active and exhibited no evidence of recurrent cholangitis.

  15. A Case of Metachronous Metastasis to the Breast from Non-Small Cell Lung Carcinoma

    PubMed Central

    Yoon, Min Yong; Song, Chang Seok; Seo, Mi Hae; Kim, Min Jae; Oh, Tae Yun; Jang, Un Ha; Kwag, Hyon Joo; Kim, Hee Sung; Lim, Si Young; Lim, Seong Yong

    2010-01-01

    Breast metastases from an extramammary primary tumor are very rare and the prognosis for such patients is generally poor. We report here on a case of a 42-year-old female with metastasis of non-small cell lung cancer to the breast, and she is now being followed up on an outpatient basis. In 2004, she presented with a solitary pulmonary nodule in the left lung, and this lesion had been noted to have gradually increased in size over time. The final pathological diagnosis was adenocarcinoma, and the diagnosis was made by performing percutaneous needle aspiration and lobectomy of the left upper lobe. Adjuvant chemotherapy and radiotherapy were given. Unfortunately, a nodule in the left breast was noted three years later, and metastatic non-small-cell lung cancer to the breast was diagnosed by excisional biopsy. Making the correct diagnosis to distinguish a primary breast carcinoma from a metastatic one is important, because the therapeutic plan and outcome for these two types of cancer are quite different. PMID:20948923

  16. Paradoxical Brain Herniation After Decompressive Craniectomy Provoked by Drainage of Subdural Hygroma.

    PubMed

    Nasi, Davide; Dobran, Mauro; Iacoangeli, Maurizio; Di Somma, Lucia; Gladi, Maurizio; Scerrati, Massimo

    2016-07-01

    Paradoxical brain herniation (PBH) is a rare and potentially life-threatening complication of decompressive craniectomy (DC) and results from the combined effects of brain gravity, atmospheric pressure and intracranial hypotension causing herniation in the direction opposite to the site of the DC with subsequent brainstem compression. To date, the cases of PBH reported in literature are spontaneous or provoked by a lumbar puncture, a cerebrospinal fluid (CSF) shunt, or ventriculostomy. We present an uncommon case of PBH provoked by percutaneous drainage of a huge subdural hygroma (SH) ipsilateral to the decompressive craniectomy causing mass effect and neurologic deterioration. After percutaneous evacuation of SH, the patient became unresponsive with dilated and fixed left pupil. A brain computed tomography scan showed marked midline shift in the direction opposite to the craniectomy site with subfalcine herniation and effacement of the peripontine cisterns. Paradoxical brain herniation (PBH) was diagnosed. Conservative treatment failed, and the patient required an emergency cranioplasty for reverse PBH. The present case highlights the possibility that all forms of CSF depletion, including percutaneous drainage of subdural CSF collection and not only CSF shunting and/or lumbar puncture, can be dangerous for patients with large craniotomies and result in PBH. Moreover, an emergency cranioplasty could represent a safe and effective procedure in patients not responding to conservative treatment. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Sojourner APXS at Moe - Right Eye

    NASA Image and Video Library

    1997-10-13

    The Sojourner rover's Alpha Proton X-ray Spectrometer (APXS) is shown deployed against the rock "Moe" on the afternoon of Sol 64 (September 7). The rocks to the left of Moe are "Shark" (left of Sojourner) and "Half Dome" (behind Sojourner). They were previously measured by the APXS. The image was taken by the Imager for Mars Pathfinder (IMP). http://photojournal.jpl.nasa.gov/catalog/PIA00966

  18. [A case of multiple hepatocellular carcinoma with rapidly progressing bilateral portal vein tumor thrombosis--a complete remission achieved with dual treatment of reductive surgery plus percutaneous isolated hepatic perfusion].

    PubMed

    Tsuchida, Shinobu; Fukumoto, Takumi; Tominaga, Masahiro; Iwasaki, Takeshi; Kusunoki, Nobuya; Sugimoto, Takemi; Kido, Masahiro; Takebe, Atsushi; Tanaka, Motofumi; Hisoka, Kinoshita; Ku, Yonson

    2005-10-01

    We herein report a case of multiple advanced hepatocellular carcinoma (HCC) with rapidly progressing portal vein tumor thrombosis (PVTT). All of the hepatic tumors have completely disappeared for more than two years by a dual treatment with reductive surgery plus percutaneous isolated hepatic perfusion (PIHP). A 55-year-old man was referred to our institution on June 30, 2003. The abdominal CT scan demonstrated multiple massive HCC in the entire liver with PVTT reaching the portal trunk (Vp4). Two weeks later, the PVTT rapidly progressed to the umbilical portion of the left portal vein, and to the confluence of the superior mesenteric vein and to the splenic vein. Thus, we semi electively performed an extended right hepatectomy together with thrombectomy of the PVTT. Subsequently, he underwent a repeated PIHP (1st; doxorubicin 90 mg/m2, 2nd doxorubicin 65 mg/m2). This treatment produced complete tumor clearance of all of the residual tumors in the left liver. In March 2005, he underwent partial pneumonectomy for a metastatic lung. This again resulted in normalization of serum AFP and PIVKA-II levels. Dual treatment is considered to be the strongest therapeutic modality for multiple advanced HCC with severe PVTT. In addition, a close follow-up is required because in such far advanced cases, metastatic lesions most likely recur in the liver but also in the distant organs.

  19. Aneurysmal rupture of the costo-cervical trunk in a patient with neurofibromatosis type 1: A case report☆

    PubMed Central

    Hoonjan, Bhupinder; Thayur, Nagendra; Abu-Own, Abdusalam

    2013-01-01

    INTRODUCTION Rupture of blood vessels associated with neurofibromatosis type 1 (NF-1) is a rare but life threatening complication. We report the first case of an aneurysmal rupture from the costocervical trunk in a NF-1 patient treated by endovascular embolisation. PRESENTATION OF CASE A 43 year-old gentleman with a past medical history of NF-1 presented with sudden onset left sided neck swelling. A computed tomography (CT) revealed a large cervical haematoma, which was causing airway compromise, requiring the patient to be intubated. Percutaneous embolisation of the bleeding vessel from the costo-cervical trunk was performed with successful haemostasis and no immediate complications. A repeat CT scan showed a reduction in the original cervical haematoma. However, six days post embolisation, the patient arrested with complete whiteout of the left hemithorax. DISCUSSION CT angiography is the gold standard for diagnosis of an aneurysmal rupture in NF-1 patients, and percutaneous embolisation is the preferred modality in patients who are haemodynamically stable due to arterial fragility and high intra operative mortality rates. The increasing haemothorax could be explained by the original cervical haematoma draining down into the pleural space, or the possibility of a new second bleed. CONCLUSION This is the first reported episode of bleeding from the costocervical trunk in NF-1 patients. Ruptured aneurysms require urgent CT angiography, if haemodynamically stable, and further input from the vascular surgeons and vascular radiologists. PMID:24463561

  20. Aneurysmal rupture of the costo-cervical trunk in a patient with neurofibromatosis type 1: A case report.

    PubMed

    Hoonjan, Bhupinder; Thayur, Nagendra; Abu-Own, Abdusalam

    2014-01-01

    Rupture of blood vessels associated with neurofibromatosis type 1 (NF-1) is a rare but life threatening complication. We report the first case of an aneurysmal rupture from the costocervical trunk in a NF-1 patient treated by endovascular embolisation. A 43 year-old gentleman with a past medical history of NF-1 presented with sudden onset left sided neck swelling. A computed tomography (CT) revealed a large cervical haematoma, which was causing airway compromise, requiring the patient to be intubated. Percutaneous embolisation of the bleeding vessel from the costo-cervical trunk was performed with successful haemostasis and no immediate complications. A repeat CT scan showed a reduction in the original cervical haematoma. However, six days post embolisation, the patient arrested with complete whiteout of the left hemithorax. CT angiography is the gold standard for diagnosis of an aneurysmal rupture in NF-1 patients, and percutaneous embolisation is the preferred modality in patients who are haemodynamically stable due to arterial fragility and high intra operative mortality rates. The increasing haemothorax could be explained by the original cervical haematoma draining down into the pleural space, or the possibility of a new second bleed. This is the first reported episode of bleeding from the costocervical trunk in NF-1 patients. Ruptured aneurysms require urgent CT angiography, if haemodynamically stable, and further input from the vascular surgeons and vascular radiologists. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Anatomical considerations of percutaneous transvenous mitral annuloplasty: a novel procedure for treatment of functional mitral regurgitation.

    PubMed

    Mehra, Lalit; Raheja, Shashi; Agarwal, Sneh; Rani, Yashoda; Kaur, Kulwinder; Tuli, Anita

    2016-03-01

    Percutaneous transvenous mitral annuloplasty (PTMA) has evolved as a latest procedure for the treatment of functional mitral regurgitation. It reduces mitral valve annulus (MVA) size and increases valve leaflet coaptation via compression of coronary sinus (CS). Anatomical considerations for this procedure were elucidated in the present study. In 40 formalin fixed adult cadaveric human hearts, relation of the venous channel formed by CS and great cardiac vein (GCV) to MVA and the adjacent arteries was described, at 6 points by making longitudinal sections perpendicular to the plane of MVA, numbered 1-6 starting from CS ostium. CS/GCV formed a semicircular venous channel on the atrial side of MVA. Based on the distance of CS/GCV from MVA, two patterns were identified. In 37 hearts, the venous channel at point 2 was widely separated from the MVA compared to the two ends and in three hearts a nonconsistent pattern was observed. GCV crossed circumflex artery superficially. GCV or CS crossed the left marginal artery and ventricular branches of circumflex artery superficially in 17 and 23 hearts, respectively. As the venous channel was related more to the left atrial wall, PTMA devices probably exert an indirect traction on MVA. The arteries crossing deep to the venous channel may be compressed by PTMA device leading to myocardial ischemia. Knowledge of the spatial relations of MVA and a preoperative and postoperative angiogram may help to reduce such complications during PTMA.

  2. Renal Sympathetic Denervation by CT-scan-Guided Periarterial Ethanol Injection in Sheep

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Firouznia, Kavous, E-mail: k-firouznia@yahoo.com; Hosseininasab, Sayed jaber, E-mail: dr.hosseininasab@gmail.com; Amanpour, Saeid, E-mail: saeidamanpour@yahoo.com

    BackgroundRenal nerves are a recent target in the treatment of hypertension. Renal sympathetic denervation (RSD) is currently performed using catheter-based radiofrequency ablation (RFA) and because this method has limitations, percutaneous magnetic resonance (MR)-guided periarterial ethanol injection is a suggested alternative. However, few studies have been conducted on the effectiveness of percutaneous ethanol injection for RSD.AimTo evaluate the feasibility, efficacy, and complications of computed tomography (CT)-guided periarterial ethanol injection.MethodsEthanol (10 ml, 99.6 %) was injected around the right renal artery in six sheep under CT guidance with the left kidney serving as a control. Before and after the intervention, the sheep underwent MRmore » imaging studies and the serum creatinine level was measured. One month after the intervention, the sheep were euthanized and norepinephrine (NE) concentration in the renal parenchyma was measured to evaluate the efficacy of the procedure. The treated tissues were also examined histopathologically to evaluate vascular, parenchymal, and neural injury.ResultsThe right kidney parenchymal NE concentration decreased significantly compared with the left kidney after intervention (average reduction: 40 %, P = 0.0016). Histologic examination revealed apparent denervation with no other vascular or parenchymal injuries observed in the histological and imaging studies.ConclusionEffective and feasible RSD was achieved using CT-guided periarterial ethanol injection. This technique may be a potential alternative to catheter-based RFA in the treatment of hypertension.« less

  3. Percutaneous coronary intervention versus coronary artery bypass grafting in patients with end-stage renal disease requiring dialysis (5-year outcomes of the CREDO-Kyoto PCI/CABG Registry Cohort-2).

    PubMed

    Marui, Akira; Kimura, Takeshi; Nishiwaki, Noboru; Mitsudo, Kazuaki; Komiya, Tatsuhiko; Hanyu, Michiya; Shiomi, Hiroki; Tanaka, Shiro; Sakata, Ryuzo

    2014-08-15

    Ischemic heart disease is a major risk factor for morbidity and mortality in patients with end-stage renal disease. However, long-term benefits of percutaneous coronary intervention (PCI) relative to coronary artery bypass grafting (CABG) in those patients is still unclear in the drug-eluting stent era. We identified 388 patients with multivessel and/or left main disease with end-stage renal disease requiring dialysis among 15,939 patients undergoing first coronary revascularization enrolled in the Coronary REvascularization Demonstrating Outcome Study in Kyoto PCI/CABG Registry Cohort-2 (PCI: 258 patients and CABG: 130 patients). The CABG group included more patients with 3-vessel (38% vs 57%, p <0.001) and left main disease (10% vs 34%, p <0.001). Preprocedural Synergy between Percutaneous Coronary Intervention with Taxus and Cardiac Surgery score in the CABG group was significantly higher than that in the PCI group (23.5 ± 8.7 vs 29.4 ± 11.0, p <0.001). Unadjusted 30-day mortality was 2.7% for PCI and 5.4% for CABG. Cumulative 5-year all-cause mortality was 52.3% for PCI and 49.9% for CABG. Propensity score-adjusted all-cause mortality was not different between PCI and CABG (hazard ratio [HR] 1.33, 95% confidence interval [CI] 0.85 to 2.09, p = 0.219). However, the excess risk of PCI relative to CABG for cardiac death was significant (HR 2.10, 95% CI 1.11 to 3.96, p = 0.02). The risk of sudden death was also higher after PCI (HR 4.83, 95% CI 1.01 to 23.08, p = 0.049). The risk of myocardial infarction after PCI tended to be higher than after CABG (HR 3.30, 95% CI 0.72 to 15.09, p = 0.12). The risk of any coronary revascularization after PCI was markedly higher after CABG (HR 3.78, 95% CI 1.91 to 7.50, p <0.001). Among the 201 patients who died during the follow-up, 94 patients (47%) died from noncardiac morbidities such as stroke, respiratory failure, and renal failure. In patients with multivessel and/or left main disease undergoing dialysis, 5-year outcomes revealed that CABG relative to PCI reduced the risk of cardiac death, sudden death, myocardial infarction, and any revascularization. However, the risk of all-cause death was not different between PCI and CABG. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Artists concept of Apollo 15 crewmen performing deployment of LRV

    NASA Image and Video Library

    1971-06-26

    S71-38189 (26 June 1971) --- An artist's concept showing the final steps of readying the Apollo 15 Lunar Roving Vehicle (LRV) or Rover 1 for mobility on the lunar surface. Performing the last few LRV deployment tasks here are, left to right, astronauts James B. Irwin, lunar module pilot, and David R. Scott, commander. More specifically the tasks depicted here include the setting up of the seats and the total releasing of the LRV from the LM. (This is the fourth in a series of four Grumman Aerospace Corporation artist's concepts telling the lunar surface LRV deployment story for Apollo 15).

  5. Brady's Geothermal Field - Map of DAS, Nodal, Vibroseis and Reftek Station Deployment

    DOE Data Explorer

    Kurt Feigl

    2016-10-15

    Map of DAS, nodal, vibroseis and Reftek stations during March 2016 deployment. The plot on the left has nodal stations labeled; the plot on the right has vibroseis observations labeled. Stations are shown in map-view using Brady's rotated X-Y coordinates with side plots denoting elevation with respect to the WGS84 ellipsoid. Blue circles denote vibroseis data, x symbols denote DAS (cyan for horizontal and magenta for vertical), black asterisks denote Reftek data, and red plus signs denote nodal data. This map can be found on UW-Madison's askja server at /PoroTomo/DATA/MAPS/Deployment_Stations.pdf

  6. [Reintervention with percutaneous balloon angioplasty in patients with congenital heart disease with left-sided obstructions].

    PubMed

    Márquez-González, Horacio; López-Gallegos, Diana; Pérez-Velázquez, Nataly Alejandra; Yáñez-Gutiérrez, Lucelli

    2017-01-01

    Left-sided cardiac obstructions represent 15% of congenital heart disease (CHD). The treatment in adults is surgical; however, balloon dilation by interventional catheterization can alleviate the symptoms in pediatric patients to allow them to reach the target height. The aim was to determine the survival and the factors associated with reintervention in patients with CHD with left-sided obstruction treated with balloon angioplasty. A cohort study was conducted in patients aged 4 to 17 years with left-sided heart obstruction (valvular stenosis [VS], supravalvular aortic stenosis [SAS], coarctation of the aorta [CA]) successfully treated with balloon angioplasty. The follow-up was of 10 years and the outcome variable was the restenosis with reintervention criteria. Pediatric stage at the time of the procedure, nutritional status, residual gradient, and presence of genetic syndromes were considered prognostic variables. For statistical analysis, measures of central tendency and dispersion were used. Chi squared was employed in qualitative variables and Kruskal-Wallis in quantitative variables. We had a total of 110 patients: 40% had CA, 35% VS, and 25% SAS. 39% required reintervention: 80% in SAS, 35% in CA, and 14% in VS. The intervention balloon is a stopgap measure that allows patients with left-sided obstructions to reach the target height.

  7. Report of a rare case: occult hemothorax due to blunt trauma without obvious injury to other organs

    PubMed Central

    2013-01-01

    Traumatic hemothorax commonly occurs accompanied by organ damage, such as rib fractures, lung injury and diaphragm rupture. Our reported patient was a 61-year-old man who fell down from a stepladder about 1 meter in height, resulting in a heavy blow to the left abdomen. He consulted a clinic because of left chest pain the next day and was transported to the emergency center of our hospital on diagnosis of hemothorax with hemorrhagic shock. On computed tomography scanning with contrast medium, left hemothorax without rib fracture, diaphragm rupture or obvious organ injury was evident. We found only bleeding to the thoracic space from a branch of the left inferior phrenic artery without involvement of the abdomen. The patient underwent percutaneous angiography and embolization for hemostasis, and subsequently thoracotomy in order to check the active bleeding and remove the hematoma to improve respiratory. As thoracotomy findings, we found damage of a branch of the left inferior phrenic artery to the thoracic space without diaphragm rupture, and sutured the lesion. Such active intervention followed by surgical procedures was effective and should be considered for rare occurrences like the present case. We must consider not only traumatic diaphragm rupture, but also vascular damage by pressure trauma as etiological factors for hemothorax. PMID:24176006

  8. Report of a rare case: occult hemothorax due to blunt trauma without obvious injury to other organs.

    PubMed

    Ogawa, Fumihiro; Naito, Masahito; Iyoda, Akira; Satoh, Yukitoshi

    2013-11-01

    Traumatic hemothorax commonly occurs accompanied by organ damage, such as rib fractures, lung injury and diaphragm rupture. Our reported patient was a 61-year-old man who fell down from a stepladder about 1 meter in height, resulting in a heavy blow to the left abdomen. He consulted a clinic because of left chest pain the next day and was transported to the emergency center of our hospital on diagnosis of hemothorax with hemorrhagic shock.On computed tomography scanning with contrast medium, left hemothorax without rib fracture, diaphragm rupture or obvious organ injury was evident. We found only bleeding to the thoracic space from a branch of the left inferior phrenic artery without involvement of the abdomen. The patient underwent percutaneous angiography and embolization for hemostasis, and subsequently thoracotomy in order to check the active bleeding and remove the hematoma to improve respiratory. As thoracotomy findings, we found damage of a branch of the left inferior phrenic artery to the thoracic space without diaphragm rupture, and sutured the lesion. Such active intervention followed by surgical procedures was effective and should be considered for rare occurrences like the present case. We must consider not only traumatic diaphragm rupture, but also vascular damage by pressure trauma as etiological factors for hemothorax.

  9. New congenital coronary artery anomaly - double supply of single left anterior descending coronary artery from the left and right coronary sinuses: a case report.

    PubMed

    Daralammouri, Yunis; Ghannam, Malik; Lauer, Bernward

    2016-08-02

    A normal anatomy of coronary arteries is important to have adequate cardiac muscle blood supply especially during extraneous physical activities. This case report describes a rare coronary anomaly in which the accessory coronary artery arose from the right coronary artery, reentered the left anterior descending coronary artery, and then ran as a single vessel. We present a case of a coronary anomaly in a 47-year-old white man who presented with atypical angina. Computed tomographic angiography and coronary angiography showed a variant of dual left anterior descending coronary artery not previously described. Our patient's accessory coronary artery arose from his right coronary artery. It took an intramuscular course beneath the right ventricular outflow tract in the interventricular septal area to the anterior interventricular sulcus, giving off septal perforators that reentered his medial left anterior descending coronary artery. Both vessels ran after the anastomosis in the anterior interventricular sulcus as a single vessel. We propose that this anomaly represents a new variant of coronary artery anomaly. This coronary artery anomaly does not cause ischemia. Recognition of this coronary anomaly is important in patients undergoing percutaneous coronary intervention or coronary artery bypass graft operations.

  10. Electric Sail (E-Sail) Tether Team

    NASA Image and Video Library

    2017-08-03

    Electric Sail (E-Sail) Tether Team Discusses 6U CubeSat Test Article and Tether Deployment System (Right to left: Tom Bryan, Davis Hunter (student intern), Jonathan MacArthur (student intern), Charles Cowen, Mike Tinker)

  11. Percutaneous closure of patent foramen ovale and atrial septal defect in adults: the impact of clinical variables and hospital procedure volume on in-hospital adverse events.

    PubMed

    Opotowsky, Alexander R; Landzberg, Michael J; Kimmel, Stephen E; Webb, Gary D

    2009-05-01

    Percutaneous closure of patent foramen ovale/atrial septal defect (PFO/ASD) is an increasingly common procedure perceived as having minimal risk. There are no population-based estimates of in-hospital adverse event rates of percutaneous PFO/ASD closure. We used nationally representative data from the 2001-2005 Nationwide Inpatient Sample to identify patients >or-=20 years old admitted to an acute care hospital with an International Classification of Diseases, Ninth Revision code designating percutaneous PFO/ASD closure on the first or second hospital day. Variables analyzed included age, sex, number of comorbidities, year, same-day use of intracardiac or other echocardiography, same-day left heart catheterization, hospital size and teaching status, PFO/ASD procedural volume, and coronary intervention volume. Outcomes of interest included length of stay, charges, and adverse events. The study included 2,555 (weighted to United States population: 12,544 +/- 1,987) PFO/ASD closure procedures. Mean age was 52.0 +/- 0.4 years, and 57.3% +/- 1.0% were women. Annual hospital volume averaged 40.8 +/- 7.7 procedures (range, 1-114). Overall, 8.2 +/- 0.8% of admissions involved an adverse event. Older patients and those with comorbidities were more likely to sustain adverse events. Use of intracardiac echocardiography was associated with fewer adverse events. The risk of adverse events was inversely proportional to annual hospital volume (odds ratio [OR] 0.91, 95% confidence interval [CI] 0.86-0.96, per 10 procedures), even after limiting the analysis to hospitals performing >or=10 procedures annually (OR 0.91, 95% CI 0.85-0.98). Adverse events were more frequent at hospitals in the lowest volume quintile as compared with the highest volume quintile (13.3% vs 5.4%, OR 2.42, 95% CI 1.55-3.78). The risk of adverse events of percutaneous PFO/ASD closure is inversely correlated with hospital volume. This relationship applies even to hospitals meeting the current guidelines, performing >or=10 procedures annually.

  12. Safety of percutaneous left atrial appendage closure: results from the Watchman Left Atrial Appendage System for Embolic Protection in Patients with AF (PROTECT AF) clinical trial and the Continued Access Registry.

    PubMed

    Reddy, Vivek Y; Holmes, David; Doshi, Shephal K; Neuzil, Petr; Kar, Saibal

    2011-02-01

    The Watchman Left Atrial Appendage System for Embolic Protection in Patients With AF (PROTECT AF) randomized trial compared left atrial appendage closure against warfarin in atrial fibrillation (AF) patients with CHADS₂ ≥1. Although the study met the primary efficacy end point of being noninferior to warfarin therapy for the prevention of stroke/systemic embolism/cardiovascular death, there was a significantly higher risk of complications, predominantly pericardial effusion and procedural stroke related to air embolism. Here, we report the influence of experience on the safety of percutaneous left atrial appendage closure. The study cohort for this analysis included patients in the PROTECT AF trial who underwent attempted device left atrial appendage closure (n=542 patients) and those from a subsequent nonrandomized registry of patients undergoing Watchman implantation (Continued Access Protocol [CAP] Registry; n=460 patients). The safety end point included bleeding- and procedure-related events (pericardial effusion, stroke, device embolization). There was a significant decline in the rate of procedure- or device-related safety events within 7 days of the procedure across the 2 studies, with 7.7% and 3.7% of patients, respectively, experiencing events (P=0.007), and between the first and second halves of PROTECT AF and CAP, with 10.0%, 5.5%, and 3.7% of patients, respectively, experiencing events (P=0.006). The rate of serious pericardial effusion within 7 days of implantation, which had made up >50% of the safety events in PROTECT AF, was lower in the CAP Registry (5.0% versus 2.2%, respectively; P=0.019). There was a similar experience-related improvement in procedure-related stroke (0.9% versus 0%, respectively; P=0.039). Finally, the functional impact of these safety events, as defined by significant disability or death, was statistically superior in the Watchman group compared with the warfarin group in PROTECT AF. This remained true whether significance was defined as a change in the modified Rankin score of ≥1, ≥2, or ≥3 (1.8 versus 4.3 events per 100 patient-years; relative risk, 0.43; 95% confidence interval, 0.24 to 0.82; 1.5 versus 3.7 events per 100 patient-years; relative risk, 0.41; 95% confidence interval, 0.22 to 0.82; and 1.4 versus 3.3 events per 100 patient-years; relative risk, 0.43; 95% confidence interval, 0.22 to 0.88, respectively). As with all interventional procedures, there is a significant improvement in the safety of Watchman left atrial appendage closure with increased operator experience. Clinical Trial Registration- URL: http://clinicaltrials.gov. Unique identifier: NCT00129545.

  13. Malignant perivascular epithelioid cell neoplasm of the mediastinum and the lung: one case report.

    PubMed

    Liang, Wenjie; Xu, Shunliang; Chen, Feng

    2015-06-01

    A perivascular epithelioid cell neoplasm (PEComa) in the chest is rare, let alone in the mediastinum and lung. A 63-year-old man was admitted to our hospital with chest pain for more than 2 months and was found to have an opacity in his mediastinum and lung for 3 weeks. Enhanced chest computed tomography (CT) revealed a mass in both the left upper lobe and central anterior mediastinum. To identify the disease, a CT-guided percutaneous transthoracic needle biopsy of the upper left lung lesions was performed. The pathology result was consistent with epithelioid angiomyolipoma/PEComa. After a standard preparation for surgery, the neoplasms in the mediastinum and left lung were resected. The operative findings revealed extensive mediastinal tumor invasion in parts adjacent to the pericardium, including the mediastinal pleura, left pulmonary artery and vein, and phrenic nerve. The left lung tumor had invaded the lung membranes. The final pathologic diagnosis was malignant epithelioid angioleiomyoma in the left upper lung and mediastinum. Later, the mediastinal tumor recurred. The radiography of this case resembles left upper lobe lung cancer with mediastinal lymph node metastasis. Because this tumor lacks fat, the enhanced CT indicated that it was malignant but failed to identify it as a perivascular epithelioid cell neoplasm.This case reminds clinicians that, although most PEComa are benign, some can be malignant. As the radiology indicated, chest PEComas lack fat, which makes their preoperative diagnosis difficult. Therefore, needle biopsy is valuable for a definitive diagnosis.

  14. Malignant Perivascular Epithelioid Cell Neoplasm of the Mediastinum and the Lung

    PubMed Central

    Liang, Wenjie; Xu, Shunliang; Chen, Feng

    2015-01-01

    Abstract A perivascular epithelioid cell neoplasm (PEComa) in the chest is rare, let alone in the mediastinum and lung. A 63-year-old man was admitted to our hospital with chest pain for more than 2 months and was found to have an opacity in his mediastinum and lung for 3 weeks. Enhanced chest computed tomography (CT) revealed a mass in both the left upper lobe and central anterior mediastinum. To identify the disease, a CT-guided percutaneous transthoracic needle biopsy of the upper left lung lesions was performed. The pathology result was consistent with epithelioid angiomyolipoma/PEComa. After a standard preparation for surgery, the neoplasms in the mediastinum and left lung were resected. The operative findings revealed extensive mediastinal tumor invasion in parts adjacent to the pericardium, including the mediastinal pleura, left pulmonary artery and vein, and phrenic nerve. The left lung tumor had invaded the lung membranes. The final pathologic diagnosis was malignant epithelioid angioleiomyoma in the left upper lung and mediastinum. Later, the mediastinal tumor recurred. The radiography of this case resembles left upper lobe lung cancer with mediastinal lymph node metastasis. Because this tumor lacks fat, the enhanced CT indicated that it was malignant but failed to identify it as a perivascular epithelioid cell neoplasm. This case reminds clinicians that, although most PEComa are benign, some can be malignant. As the radiology indicated, chest PEComas lack fat, which makes their preoperative diagnosis difficult. Therefore, needle biopsy is valuable for a definitive diagnosis. PMID:26039123

  15. [Clinical characteristics among CABG or PCI which to treat chronic kidney disease with unprotected left main coronary artery disease].

    PubMed

    Pan, Yu; Qiu, Qi; Zhang, Yunting; Luo, Yawei; Yu, Xianpeng; He, Jiqiang; Li, Quan

    2015-05-12

    To explore the clinical characteristics and prognosis of patients with chronic kidney disease with unprotected left main (ULM) coronary artery disease undergoing coronary artery bypass grafting (CABG) or percutaneous coronary intervention (PCI). A total of 601 unprotected left main coronary artery disease patients were recruited. According to the values of endogenous creatinine clearance rate (Ccr), they were divided into three groups of <45 ml/min (n=40), 45-59 ml/min (n=96) and ≥60 ml/min (n=465). Retrospective comparisons were made for the clinical parameters and prognosis of ULM patients in different Ccr groups with different therapies. In Ccr≥60 ml/min group, the valves of left ventricular ejection fraction (LVEF) were lower in patients undergoing CABG. Patients with complete total occlusion (CTO) and complete revascularizations were much more than those undergoing PCI. In Ccr≥60 ml/min and Ccr 45-59 ml/min groups, multivessel disease was frequent in CABG-treated patients. No significant difference existed among three groups in major adverse cardiac and cerebrovascular event (MACCE), overall mortality or cardiac mortality. PCI is both safe and efficacious for chronic renal insufficiency patients with ULM.

  16. Comparison of the feasibility and effectiveness of transradial coronary angiography via right versus left radial artery approaches (from the PREVAIL Study).

    PubMed

    Pelliccia, Francesco; Trani, Carlo; Biondi-Zoccai, Giuseppe G L; Nazzaro, Marco; Berni, Andrea; Patti, Giuseppe; Patrizi, Roberto; Pironi, Bruno; Mazzarotto, Pietro; Gioffrè, Gaetano; Speciale, Giulio; Pristipino, Christian

    2012-09-15

    It remains undefined if transradial coronary angiography from a right or left radial arterial approach differs in real-world practice. To address this issue, we performed a subanalysis of the PREVAIL study. The PREVAIL study was a prospective, multicenter, observational survey of unselected consecutive patients undergoing invasive cardiovascular procedures over a 1-month observation period, specifically aimed at assessing the outcomes of radial approach in the contemporary real world. The choice of arterial approach was left to the discretion of the operator. Prespecified end points of this subanalysis were procedural characteristics. Of 1,052 patients consecutively enrolled, 509 patients underwent transradial catheterization, 304 with a right radial and 205 with a left radial approach. Procedural success rates were similar between the 2 groups. Compared to the left radial group, the right radial group had longer procedure duration (46 ± 29 vs 33 ± 24 minutes, p <0.0001) and fluoroscopy time (765 ± 787 vs 533 ± 502, p <0.0001). At multivariate analysis, including a parsimonious propensity score for the choice of left radial approach, duration of procedure (beta coefficient 11.38, p <0.001) and total dose-area product (beta coefficient 11.38, p <0.001) were independently associated with the choice of the left radial artery approach. The operator's proficiency in right/left radial approach did not influence study results. In conclusion, right and left radial approaches are feasible and effective to perform percutaneous procedures. In the contemporary real world, however, the left radial route is associated with shorter procedures and lower radiologic exposure than the right radial approach, independently of an operator's proficiency. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. Complex Recanalization of Chronic Total Occluison Supported by Minimal Extracorporeal Circulation in a Patient with an Aortic Valve Bioprothesis in Extraanatomic Position

    PubMed Central

    Jansen, Ruben; Bathgate, Brigitte; Bufe, Alexander

    2018-01-01

    Percutaneous coronary intervention (PCI) of chronic total occlusion (CTO) still remains a major challenge in interventional cardiology. This case describes a complex PCI of the left main coronary artery and of a CTO of the right coronary artery using a minimal extracorporeal circulation system (MECC) in a patient with an aortic valve bioprothesis in extraanatomic position. It illustrates that complex recanalization strategies can be solved combining it with mechanical circulatory support technologies. PMID:29850264

  18. Long-Term Outcomes of Stenting the Proximal Left Anterior Descending Artery in the PROTECT Trial.

    PubMed

    Roguin, Ariel; Camenzind, Edoardo; Kerner, Arthur; Beyar, Rafael; Boersma, Eric; Mauri, Laura; Steg, Ph Gabriel; Wijns, William

    2017-03-27

    This study sought to compare the outcomes of patients undergoing drug-eluting stent implantation according to lesion location within or outside the proximal left anterior descending (LAD) artery. Proximal LAD artery involvement is considered uniquely in revascularization guidelines. The impact of LAD lesion location on long-term outcomes after revascularization is poorly understood in context of current percutaneous coronary intervention and medical therapy. Among 8,709 patients enrolled in PROTECT (Patient Related Outcomes with Endeavor Versus Cypher Stenting Trial), a multicenter percutaneous coronary intervention trial, we compared the outcomes of 2,534 patients (29.1%) (3,871 lesions [31.5%]) with stents implanted in the proximal LAD to 6,172 patients (70.9%) (8,419 lesions [68.5%]) with stents implanted outside the proximal LAD. At the 4-year follow-up, death rates were the same (5.8% vs. 5.8%; p > 0.999), but more myocardial infarctions occurred in the proximal LAD group (6.2% vs. 4.9%; p = 0.015). The rate of clinically driven target vessel failure (TVF) (14.8% vs. 13.5%; p = 0.109), major adverse cardiac event(s) (MACE) (15.0% vs. 13.7%; hazard ratio: 1.1; 95% confidence interval: 0.97 to 1.31; p = 0.139), and stent thrombosis (2.1% vs. 2.0%; p = 0.800) were similar. Drug-eluting stent type had no interaction with MACE or TVF. In multivariate analysis, the proximal LAD was a predictor of myocardial infarction (p = 0.038) but not of TVF (p = 0.149) or MACE (p = 0.069). In this study of contemporary percutaneous coronary intervention, proximal LAD location was associated with higher rates of myocardial infarction during the long-term follow-up, but there were no differences in stent thrombosis, death, TVF, or overall MACE. This finding may suggest that, in the drug-eluting stent era, proximal LAD no longer confers a different prognosis than other lesion sites. (Randomized Study Comparing Endeavor With Cypher Stents [PROTECT]; NCT00476957). Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. Cost-Effectiveness of Percutaneous Closure of the Left Atrial Appendage in Atrial Fibrillation Based on Results From PROTECT AF Versus PREVAIL.

    PubMed

    Freeman, James V; Hutton, David W; Barnes, Geoffrey D; Zhu, Ruo P; Owens, Douglas K; Garber, Alan M; Go, Alan S; Hlatky, Mark A; Heidenreich, Paul A; Wang, Paul J; Al-Ahmad, Amin; Turakhia, Mintu P

    2016-06-01

    Randomized trials of left atrial appendage (LAA) closure with the Watchman device have shown varying results, and its cost effectiveness compared with anticoagulation has not been evaluated using all available contemporary trial data. We used a Markov decision model to estimate lifetime quality-adjusted survival, costs, and cost effectiveness of LAA closure with Watchman, compared directly with warfarin and indirectly with dabigatran, using data from the long-term (mean 3.8 year) follow-up of Percutaneous Closure of the Left Atrial Appendage Versus Warfarin Therapy for Prevention of Stroke in Patients With Atrial Fibrillation (PROTECT AF) and Prospective Randomized Evaluation of the Watchman LAA Closure Device in Patients With Atrial Fibrillation (PREVAIL) randomized trials. Using data from PROTECT AF, the incremental cost-effectiveness ratios compared with warfarin and dabigatran were $20 486 and $23 422 per quality-adjusted life year, respectively. Using data from PREVAIL, LAA closure was dominated by warfarin and dabigatran, meaning that it was less effective (8.44, 8.54, and 8.59 quality-adjusted life years, respectively) and more costly. At a willingness-to-pay threshold of $50 000 per quality-adjusted life year, LAA closure was cost effective 90% and 9% of the time under PROTECT AF and PREVAIL assumptions, respectively. These results were sensitive to the rates of ischemic stroke and intracranial hemorrhage for LAA closure and medical anticoagulation. Using data from the PROTECT AF trial, LAA closure with the Watchman device was cost effective; using PREVAIL trial data, Watchman was more costly and less effective than warfarin and dabigatran. PROTECT AF enrolled more patients and has substantially longer follow-up time, allowing greater statistical certainty with the cost-effectiveness results. However, longer-term trial results and postmarketing surveillance of major adverse events will be vital to determining the value of the Watchman in clinical practice. © 2016 American Heart Association, Inc.

  20. The impact of hybrid coronary revascularization on hospital costs and reimbursements.

    PubMed

    Halkos, Michael E; Ford, Lauren; Peterson, Dane; Bluestein, Sheryl M; Liberman, Henry A; Kilgo, Patrick; Puskas, John D; Guyton, Robert A; Chowdhury, Ritam

    2014-05-01

    Hybrid coronary revascularization (HCR) combines a minimally invasive, left internal mammary artery-left anterior descending coronary artery (LAD) bypass with percutaneous intervention of non-LAD vessels for patients with multivessel coronary disease. The financial implications of HCR have not been compared with off-pump coronary artery bypass (OPCAB) through sternotomy. The contribution margin is a fiduciary calculation (best hospital payment estimate--total variable costs) used by hospitals to determine fiscal viability of services. From 2010 to 2011, 26 Medicare patients underwent HCR at a single United States institution and were compared with 28 randomly selected, contemporaneous Medicare patients undergoing multivessel OPCAB. All HCR patients underwent a robotic-assisted, sternal-sparing, off-pump, left internal mammary artery-LAD anastomosis plus percutaneous intervention to non-LAD vessels. A linear regression model was used to compare fiscal and utilization outcomes of HCR to OPCAB adjusted for hospital length of stay and The Society of Thoracic Surgeons Predicted Risk of Mortality score. On regression analysis controlling for overall length of stay and Predicted Risk of Mortality score, the contribution margin (+$8,771, p<0.0001) was greater for HCR than for OPCAB. Despite higher total cost for HCR compared with OPCAB (+$7,026, p=0.001), the total variable cost (+$2,281, p=0.07) was not significantly different. Best payment estimates (+11,031, p<0.0001) and Medicare reimbursements (+$8,992, p=0.002) were higher for HCR than for OPCAB, and there was a reduction in blood transfusion (-1.5 units, p<0.0001), ventilator time (-10 hours, p=0.001), and postoperative length of stay (-1.2 days, p=0.002) for the HCR group. Compared with OPCAB, HCR results in a greater contribution margin for hospitals. This may result from higher reimbursement as well as improved resource utilization postoperatively, which may offset more expensive procedural costs associated with HCR. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Prognostic value of N-terminal pro-B-type natriuretic peptide in patients with acute coronary syndromes undergoing left main percutaneous coronary intervention.

    PubMed

    Jaberg, Laurenz; Toggweiler, Stefan; Puck, Marietta; Frank, Michelle; Rufibach, Kaspar; Lüscher, Thomas F; Corti, Roberto

    2011-01-01

    Patients undergoing acute left main (LM) coronary artery revascularization have a high mortality and natriuretic peptides such as N-terminal pro-B-type (NT-proBNP) have been shown to have prognostic value in patients with acute coronary syndromes. The present study looked at the prognostic value of NT-proBNP in these patients. We studied all consecutive patients undergoing acute LM coronary artery percutaneous coronary intervention between January 2005 and December 2008 in whom NT-proBNP was measured (n=71). We analyzed the clinical characteristics and the short- and long-term outcomes in relation to NT-proBNP level at admission. Median NT-proBNP was 1,364 ng/L, ranging from 46 to 70,000 ng/L. NT-proBNP was elevated in 63 (89%) patients and was ≥1,000ng/L in 42 (59%). Log NT-proBNP (hazard ratio [HR] 3.51, 95% confidence interval [CI] 1.55-7.97, P=0.003) and left ventricular ejection fraction (HR 0.95, 95%CI 0.91-0.99, P=0.007) were predictors for all-cause mortality. Log NT-proBNP was the only independent significant predictor of cardiovascular mortality. In-hospital mortality was 0% for patients with NT-proBNP <1,000, but 17% for those with NT-proBNP ≥1,000 (P=0.036). NT-proBNP is a strong predictor of outcome in patients undergoing acute LM coronary artery stenting. Mortality in such patients is high, but those with NT-proBNP < 1,000ng/L may have a favorable short- and long-term prognosis. Further research, including a larger patient population, is needed to determine the optimal cut-off value for NT-proBNP in patients undergoing acute LM coronary artery intervention.

  2. [Percutaneous coronary intervention of unprotected left main coronary compared with coronary artery bypass grafting; 3 years of experience in the National Institute of Cardiology, Mexico].

    PubMed

    López-Aguilar, Carlos; Abundes-Velasco, Arturo; Eid-Lidt, Guering; Piña-Reyna, Yigal; Gaspar-Hernández, Jorge

    The best revascularisation method of the unprotected left main artery is a current and evolving topic. A total of 2439 percutaneous coronary interventions (PCI) were registered during a 3-year period. The study included all the patients with PCI of the unprotected left main coronary (n=48) and matched with patients who underwent coronary artery bypass graft (CABG) (n=50). Major adverse cerebral and cardiac events (MACCE) were assessed within the hospital and in outpatients during a 16 month follow up. The cardiovascular risk was greater in the PCI group; logEuroSCORE 16±21 vs. 5±6, P=.001; clinical Syntax 77±74 vs 53±39, P=.04. On admission, the PCI group of patients had a higher frequency of ST segment elevation myocardial infarction (STEMI) and cardiogenic shock. The MACCE were similar in both groups (14% vs. 18%, P=.64). STEMI was less frequent in the PCI group (0% vs. 10%, P=.03). Cardiovascular events were lower in the PCI group (2.3% vs. 18%, P=.01), and there was a decrease in general and cardiac mortality (2.3% vs. 12%, P=.08 y 2.3% vs. 8%, P=.24), on excluding the patients with cardiogenic shock as a presentation. MACCE were similar in both groups in the out-patient phase (15% vs. 12%, P=.46). Survival without MACCE, general and cardiac death were comparable between groups (log rank, P=.38, P=.44 and P=.16, respectively). Even though the clinical and peri-procedural risk profile of the PCI patients were higher, the in-hospital and out-hospital efficacy and safety were comparable with CABG. Copyright © 2016 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  3. Significance of off-pump coronary artery bypass grafting compared with percutaneous coronary intervention: a propensity score analysis.

    PubMed

    Marui, Akira; Kimura, Takeshi; Tanaka, Shiro; Furukawa, Yutaka; Kita, Toru; Sakata, Ryuzo

    2012-01-01

    Although there have been several studies that compared the efficacy of percutaneous coronary intervention (PCI) and coronary artery bypass grafting (CABG), the impact of off-pump CABG (OPCAB) has not been well elucidated. The objective of the present study was to compare the outcomes after PCI, on-pump CABG (ONCAB), and OPCAB in patients with multivessel and/or left main disease. Among the 9877 patients undergoing first PCI using bare-metal stents or CABG who were enrolled in the CREDO-Kyoto Registry, 6327 patients with multivessel and/or left main disease were enrolled into the present study (67.9±9.8 years old). Among them, 3877 patients received PCI, 1388 ONCAB, and 1069 OPCAB. Median follow-up was 3.5 years. Comparing PCI with all CABG (ONCAB and OPCAB), propensity-score-adjusted all-cause mortality after PCI was higher than that CABG (hazard ratio (95% confidence interval): 1.37 (1.15-1.63), p<0.01). The incidence of stroke was lower after PCI than that after CABG (0.75 (0.59-0.96), p=0.02). CABG was associated with better survival outcomes than PCI in the elderly (interaction p=0.04). Comparing OPCAB with PCI or ONCAB, propensity-score-adjusted all-cause mortality after PCI was higher than that after OPCAB (1.50 (1.20-1.86), p<0.01). Adjusted mortality was similar between ONCAB and OPCAB (1.18 (0.93-1.51), p=0.33). The incidence of stroke after OPCAB was similar to that after PCI (0.98 (0.71-1.34), p>0.99), but incidence of stroke after ONCAB was higher than that after OPCAB (1.59 (1.16-2.18), p<0.01). In patients with multivessel and/or left main disease, CABG, particularly OPCAB, is associated with better survival outcomes than PCI using bare-metal stents. Survival outcomes are similar between ONCAB and OPCAB.

  4. Prognostic utility of left ventricular end-diastolic pressure in patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention.

    PubMed

    Planer, David; Mehran, Roxana; Witzenbichler, Bernhard; Guagliumi, Giulio; Peruga, Jan Z; Brodie, Bruce R; Dudek, Dariusz; Möckel, Martin; Reyes, Selene Leon; Stone, Gregg W

    2011-10-15

    Measurement of left ventricular end-diastolic pressure (LVEDP) is readily obtainable in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI). However, the prognostic utility of LVEDP during primary PCI has never been studied. LVEDP was measured in 2,797 patients during primary PCI in the Harmonizing Outcomes with RevascularIZatiON and Stents in Acute Myocardial Infarction (HORIZONS-AMI) trial. Outcomes were assessed at 30 days and 2 years stratified by medians of LVEDP. Multivariable analysis was performed to determine whether LVEDP was an independent determinate of adverse outcomes. The median (interquartile range) for LVEDP was 18 mm Hg (12 to 24). For patients with LVEDP >18 mm Hg versus those with ≤18 mm Hg, hazard ratios (95% confidence intervals) for death and death or reinfarction at 30 days were 2.00 (1.20 to 3.33, p = 0.007) and 1.84 (1.24 to 2.73, p = 0.002), respectively, and at 2 years were 1.57 (1.12 to 2.21, p = 0.009) and 1.45 (1.14 to 1.85, p = 0.002), respectively. Patients in the highest quartile of LVEDP (≥24 mm Hg) were at the greatest risk of mortality. Only a weak correlation was present between LVEDP and left ventricular ejection fraction (LVEF; R(2) = 0.03, p <0.01). By multivariable analysis increased LVEDP was an independent predictor of death or reinfarction at 2 years (hazard ratio 1.20, 95% confidence interval 1.02 to 1.42, p = 0.03) even after adjustment for baseline LVEF. In conclusion, baseline increased LVEDP is an independent predictor of adverse outcomes in patients with STEMI undergoing primary PCI even after adjustment for baseline LVEF. Patients with LVEDP ≥24 mm Hg are at the greatest risk for early and late mortality. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. Comparison of Safety and Effectiveness Between Right Versus Left Radial Arterial Access in Primary Percutaneous Coronary Intervention for Acute ST Segment Elevation Myocardial Infarction.

    PubMed

    Elmahdy, Mahmoud Farouk; ElMaghawry, Mohamed; Hassan, Mohamed; Kassem, Hussien Heshmat; Said, Karim; Elfaramawy, Amr AbdelAziz

    2017-01-01

    Transradial approach (TRA) is now considered the standard of care in many centres for elective and primary percutaneous intervention (PCI). The use of the radial approach in ST segment elevation myocardial infarction (STEMI) patients has been associated with a significant reduction in major adverse cardiac events. However, it is still unclear if the side of radial access (right vs. left) has impact on safety and effectiveness of TRA in primary PCI. So this study was conducted to compare the safety, feasibility, and outcomes of right radial access (RRA) vs. left radial access (LRA) in the setting of primary PCI. We retrospectively analysed the data of 400 consecutive patients presenting to our institution with STEMI for whom primary PCIs were performed via RRA and LRA. Mean age of the whole studied population was 57±12.8 years, with male predominance (77.2%). There were 202 cases in the RRA group and 198 in the LRA group, with no significant difference in demographics and clinical characteristics for patients included in both groups. There was no significant difference in procedure success rate (97.5% for RRA vs. 98.4% for LRA; P=0.77). In addition, no significant difference between both approaches was observed in the contrast volume, number of catheters, fluoroscopy time (FT), needle-to-balloon time, post-procedure vascular complications, in hospital reinfarction, stroke/transient ischaemic attack (TIA) or death. Right radial access and LRA are equally safe and effective in the setting of primary PCI. Both approaches have a high success rate and comparable needle-to-balloon time. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  6. Sex differences in left main coronary artery stenting: Different characteristics but similar outcomes for women compared with men.

    PubMed

    Shin, Eun-Seok; Lee, Cheol Whan; Ahn, Jung-Min; Lee, Pil Hyung; Chang, Mineok; Kim, Min-Ju; Yoon, Sung-Han; Park, Duk-Woo; Kang, Soo-Jin; Lee, Seung-Whan; Kim, Young-Hak; Park, Seong-Wook; Park, Seung-Jung

    2018-02-15

    The clinical outcomes for women compared with men undergoing left main PCI were sparse. We compared the characteristics and long-term outcomes in women versus men after percutaneous coronary intervention (PCI) with drug-eluting stents (DES) for unprotected left main CAD. We identified 2328 patients (545 women; 1783 men) with unprotected left main CAD who received PCI with DES between January 2007 and December 2013 in the Interventional Cardiology Research In-cooperation Society-left MAIN revascularization (IRIS-MAIN) registry. The primary outcome was a composite of death from any cause, myocardial infarction, or stroke. The median follow-up time was 2.9years (interquartile range: 1.0-4.1years). Women were older, had a higher incidence of insulin-requiring diabetes mellitus and hypertension, and more commonly presented with acute coronary syndrome than men. Left main ostial lesion was more common in women, whereas left main bifurcation lesion with more extensive CAD was more common in men. The incidence of primary outcome was similar between the two groups (10.8% vs. 10.8%, respectively, log-rank p=0.587). The results were similar after adjustment for baseline variables and consistent across major subgroups. The need for target lesion revascularization was significantly higher in women than in men (8.8% vs. 5.7%, respectively, p<0.05) but the sex bias was not confirmed after adjusting for confounders. Women, as compared to men, had different clinical and lesion characteristics but similar long-term outcomes after PCI with DES for left main CAD. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Longitudinal Deformation of Distal Edge in a New-Generation Stent Caused by Guidewire Entrapment

    PubMed Central

    Taleb, Adam; Parikh, Gaurav

    2018-01-01

    Longitudinal stent deformation, described in some older stent geometries, prompted design modifications such as reinforcing struts on the proximal end. However, distal edges of stents—also subject to longitudinal force—have not been reinforced. We report a case of guidewire entrapment that deformed the distal edge of a new-generation stent during percutaneous coronary intervention, and we describe our efforts to restore the stent to its initial length. This case highlights the risk of manipulating equipment beyond the position of a newly deployed stent, the ongoing potential for deformation of distal edges in newer stent platforms, and the advisability of treating distal lesions before proximal ones. PMID:29556153

  8. Curiosity Wheel During Descent

    NASA Image and Video Library

    2012-08-07

    This color thumbnail image was obtained by NASA Curiosity rover illustrating the first appearance of the left front wheel of the Curiosity rover after deployment of the suspension system as the vehicle was about to touch down on Mars.

  9. Challenges to clinical deployment of upper limb neuroprostheses.

    PubMed

    Triolo, R; Nathan, R; Handa, Y; Keith, M; Betz, R R; Carroll, S; Kantor, C

    1996-04-01

    The technology for functional neuromuscular stimulation (FNS) as a means of providing upper limb function to people with tetraplegia has been under development by three clinical research groups for almost two decades. This paper presents the current status of the clinical trials of three FNS systems: a noninvasive system built into a cosmetic forearm splint, a 30-channel percutaneous system, and an 8-channel implantable system. The complexity of FNS systems and the unique characteristics of the individuals to whom they are applied combine to create many clinical and technical challenges that must be addressed before the devices can be deployed. The emerging challenges to widespread clinical introduction of FNS systems for hand and arm function are identified and analyzed. In addition to the demands of designed and conducting the clinical trials to satisfy regulatory requirements, the lack of knowledge, skepticism, and the complacency on the part of potential FNS recipients, as well as of rehabilitation professionals, must be overcome through education and careful consideration of economic and societal factors in the design of clinical systems.

  10. Percutaneous Transluminal Angioplasty for Complete Membranous Obstruction of Suprahepatic Inferior Vena Cava: Long-Term Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kucukay, Fahrettin, E-mail: fkucukay@hotmail.com; Akdogan, Meral, E-mail: akdmeral@yahoo.com; Bostanci, Erdal Birol, E-mail: ebbostanci@yahoo.com

    PurposeTo determine the long-term results of percutaneous transluminal angioplasty (PTA) for a complete membranous obstruction of the suprahepatic inferior vena cava.MethodsPatients (n = 65) who were referred to the interventional unit for PTA for a complete membranous obstruction of the suprahepatic inferior vena cava between January 2006 and October 2014 were included in the study. Thirty-two patients (18 males, 14 females, mean age 35 ± 10.7, range 20–42 years) were treated. The patients presented with symptoms of ascites (88 %), pleural effusion (53 %), varicose veins (94 %), hepatomegaly (97 %), abdominal pain (84 %), and splenomegaly (40 %). Transjugular liver access set and re-entry catheter were used to puncture andmore » traverse the obstruction from the jugular side. PTA balloon dilations were performed. The mean follow-up period was 65.6 ± 24.5 months. The objective was to evaluate technical success, complications, primary patency, and clinical improvement in the symptoms of the patients.ResultsThe technical success rate was 94 %. In two patients, obstruction could not be traversed. These patients underwent cavoatrial graft bypass surgery. There were no procedure-related complications. Clinical improvements were achieved in all patients within 3 months. The primary patency rate at 4 years was 90 %. There was no primary assisted patency. There was no need for metallic stent deployment in the cohort. The secondary patency rate at 4 years was 100 %.ConclusionsPercutaneous transluminal angioplasty for a complete membranous obstruction of the suprahepatic inferior vena cava is safe and effective, and the long-term results are excellent.« less

  11. Patent ductus arteriosus closure using Occlutech® Duct Occluder, experience in Port Elizabeth, South Africa

    PubMed Central

    Pepeta, Lungile; Greyling, Adele; Nxele, Mahlubandile Fintan; Makrexeni, Zongezile Masonwabe

    2017-01-01

    Background: Percutaneous closure of patent ductus arteriosus (PDA) has become standard therapy. Experience with the Occlutech® Duct Occluder is limited. Methods: Data regarding ductal closure using Occlutech® Duct Occluder were reviewed and prospectively collected. Demographics, hemodynamic and angiographic characteristics, complications, and outcomes were documented. Results: From March 2013 to June 2016, 65 patients (43 females and 22 males) underwent percutaneous closure of the PDA using Occlutech® Duct Occluder. The median age of the patients was 11 months (range, 1–454 months) and the median weight was 8.5 kg (range 2.5–78 kg). The mean pulmonary artery median pressure was 27 mmHg (range, 12–100 mmHg) and the QP: Qs ratio median was 1.8 (range, 1–7.5), with a pulmonary vascular resistance mean of 2.7 WU (standard deviation [SD] ±2.1). Thirty-two patients had Krichenko Type A duct (49%); 7, Type C (11%); 4, Type D (6%); and 22, Type E (34%). The ductal size (narrowest diameter at the pulmonic end) mean was 3.5 mm (SD ± 1.9 mm). The screening time mean was 17.3 min (SD ± 11.6). Out of 63 patients with successful closure of the PDA using Occlutech® Duct Occluder, there were 15 patients with small PDAs; 25 with moderate PDAs, and 23 with large PDAs. In one patient, the device dislodged to the descending aorta, and in two patients, to the right pulmonary artery immediately following deployment, with successful percutaneous (two) and surgical (one) retrieval. Complete ductal occlusion was achieved in all 63 patients on day one. Conclusion: The Occlutech® Duct Occluder is a safe and effective device for closure of ducts in appropriately selected patients. PMID:28566820

  12. Patent ductus arteriosus closure using Occlutech® Duct Occluder, experience in Port Elizabeth, South Africa.

    PubMed

    Pepeta, Lungile; Greyling, Adele; Nxele, Mahlubandile Fintan; Makrexeni, Zongezile Masonwabe

    2017-01-01

    Percutaneous closure of patent ductus arteriosus (PDA) has become standard therapy. Experience with the Occlutech® Duct Occluder is limited. Data regarding ductal closure using Occlutech® Duct Occluder were reviewed and prospectively collected. Demographics, hemodynamic and angiographic characteristics, complications, and outcomes were documented. From March 2013 to June 2016, 65 patients (43 females and 22 males) underwent percutaneous closure of the PDA using Occlutech® Duct Occluder. The median age of the patients was 11 months (range, 1-454 months) and the median weight was 8.5 kg (range 2.5-78 kg). The mean pulmonary artery median pressure was 27 mmHg (range, 12-100 mmHg) and the QP: Qs ratio median was 1.8 (range, 1-7.5), with a pulmonary vascular resistance mean of 2.7 WU (standard deviation [SD] ±2.1). Thirty-two patients had Krichenko Type A duct (49%); 7, Type C (11%); 4, Type D (6%); and 22, Type E (34%). The ductal size (narrowest diameter at the pulmonic end) mean was 3.5 mm (SD ± 1.9 mm). The screening time mean was 17.3 min (SD ± 11.6). Out of 63 patients with successful closure of the PDA using Occlutech® Duct Occluder, there were 15 patients with small PDAs; 25 with moderate PDAs, and 23 with large PDAs. In one patient, the device dislodged to the descending aorta, and in two patients, to the right pulmonary artery immediately following deployment, with successful percutaneous (two) and surgical (one) retrieval. Complete ductal occlusion was achieved in all 63 patients on day one. The Occlutech® Duct Occluder is a safe and effective device for closure of ducts in appropriately selected patients.

  13. Asymmetric hindwing foldings in rove beetles.

    PubMed

    Saito, Kazuya; Yamamoto, Shuhei; Maruyama, Munetoshi; Okabe, Yoji

    2014-11-18

    Foldable wings of insects are the ultimate deployable structures and have attracted the interest of aerospace engineering scientists as well as entomologists. Rove beetles are known to fold their wings in the most sophisticated ways that have right-left asymmetric patterns. However, the specific folding process and the reason for this asymmetry remain unclear. This study reveals how these asymmetric patterns emerge as a result of the folding process of rove beetles. A high-speed camera was used to reveal the details of the wing-folding movement. The results show that these characteristic asymmetrical patterns emerge as a result of simultaneous folding of overlapped wings. The revealed folding mechanisms can achieve not only highly compact wing storage but also immediate deployment. In addition, the right and left crease patterns are interchangeable, and thus each wing internalizes two crease patterns and can be folded in two different ways. This two-way folding gives freedom of choice for the folding direction to a rove beetle. The use of asymmetric patterns and the capability of two-way folding are unique features not found in artificial structures. These features have great potential to extend the design possibilities for all deployable structures, from space structures to articles of daily use.

  14. Comparison of the Efficacy and Safety of Orbital and Rotational Atherectomy in Calcified Narrowings in Patients Who Underwent Percutaneous Coronary Intervention.

    PubMed

    Koifman, Edward; Garcia-Garcia, Hector M; Kuku, Kayode O; Kajita, Alexandre H; Buchanan, Kyle D; Steinvil, Arie; Rogers, Toby; Bernardo, Nelson L; Lager, Robert; Gallino, Robert A; Ben-Dor, Itsik; Pichard, Augusto D; Torguson, Rebecca; Gai, Jiaxiang; Satler, Lowell F; Waksman, Ron

    2018-04-15

    We aimed to compare the safety and efficacy of rotational atherectomy (RA) and orbital atherectomy (OA) during percutaneous coronary intervention in an all-comer population with severely calcified lesions. We included all patients who underwent percutaneous coronary intervention with OA or RA in our institution from October 2013 until October 2016. Comparison of baseline and procedural characteristics, along with acute complication rates and postprocedural cardiac enzyme elevation, was performed. There were 191 RA and 57 OA patients. Other than creatinine clearance, which was lower in patients with OA (p = 0.01), there were no differences in baseline characteristics. OA was more frequent in left anterior descending artery lesions (p = 0.02), whereas RA was more common in right coronary artery lesions (p = 0.01). Intracoronary imaging rates were above 60% in both groups. There was a higher rate of coronary dissections with OA compared with RA (p = 0.003), but there was no difference in periprocedural events. Maximal troponin levels were similar in both groups. Residual stenosis measured by intravascular ultrasound in 29 patients revealed no significant differences between OA and RA (p = 0.58). In conclusion, RA and OA have similar safety and efficacy profiles in treating patients with calcified coronary lesions, and intracoronary imaging is highly beneficial in identifying coronary injury after atherectomy procedures. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Percutaneous intrapericardial echocardiography during catheter ablation: a feasibility study.

    PubMed

    Horowitz, Barbara Natterson; Vaseghi, Marmar; Mahajan, Aman; Cesario, David A; Buch, Eric; Valderrábano, Miguel; Boyle, Noel G; Ellenbogen, Kenneth A; Shivkumar, Kalyanam

    2006-11-01

    Percutaneous pericardial access, epicardial mapping, and ablation have been used successfully for catheter ablation procedures. The purpose of this study was to evaluate the safety and feasibility of closed-chest direct epicardial ultrasound imaging for aiding cardiac catheter ablation procedures. An intracardiac ultrasound catheter was used for closed-chest epicardial imaging of the heart in 10 patients undergoing percutaneous epicardial access for catheter ablation. All patients underwent concomitant intracardiac echocardiography and preprocedural transesophageal echocardiography. Using a double-wire technique, two sheaths were placed in the pericardium, and a phased-array ultrasound catheter was manipulated within the pericardial sinuses for imaging. Multiple images from varying angles were obtained for catheter navigation. Notably, image stability was excellent, and structures such as the left atrial appendage were seen in great detail. No complications resulting from use of the ultrasound catheter in the pericardium occurred, and no restriction of movement due to the presence of the additional catheter in the pericardial space was observed. Wall motion was correlated to voltage maps in five patients and showed that areas of scars correlated with wall-motion abnormalities. Normal wall-motion score correlated to sensed signals of 4.2 +/- 0.3 mV (normal myocardium >1.5 mV), and scores >1 correlated to areas with signals <0.5 mV in that territory). Intrapericardial imaging using an ultrasound catheter is feasible and safe and has the potential to provide additional valuable information for complex ablation procedures.

  16. Percutaneous Treatment of Renal Cysts with OK-432 Sclerosis

    PubMed Central

    Cho, Soung Yong; Cho, Kang Su; Lee, Dong Hoon; Lee, Seung Hwan

    2007-01-01

    Purpose The aim of this study was to demonstrate OK-432 sclerotherapy efficacy for treatment of simple renal cysts. Materials and Methods Twenty patients with 25 symptomatic or large simple cysts were treated by ultrasonography (US)-guided percutaneous aspiration and injection of OK-432 (8 men and 12 women, mean age 63.6 years, SD 9.5). Six patients presented with flank pain, 14 presented with renal mass; renal cyst location was right, left, or bilateral sided in 9, 8, and 8 kidneys, respectively. Patients were evaluated by clinical assessment, US, or CT scan 3 months following the procedure. Complete and partial success was defined as symptom resolution with either total cyst ablation or greater than 70% reduction, respectively. Failure was defined as 30% of cyst size recurrence and/or persistent symptoms. Results Average reduction was 93.0%. Complete and partial resolution occurred in 11 (44.0%) and 13 (52.0%) cysts, respectively. One case was defined as failure, with a 64.2% size reduction from 10.9cm to 3.9cm (volume reduction rate 95.4%). Renal pain improved in all patients, regardless of complete or partial resolution. Minor complications occurred in 3 patients, 2 developed leukocytosis and 1 had mild fever (< 38.5℃) following aspiration and sclerotherapy. Successful treatment was achieved with conservative measures and NSAID therapy. Conclusion Percutaneous treatment of simple renal cysts with OK-432 sclerotherapy was found to be a safe, effective and minimally invasive procedure. PMID:17461526

  17. Transcatheter closure of atrial septal defects type 2 in children under 3 years of age.

    PubMed

    Knop, Mateusz T; Białkowski, Jacek; Szkutnik, Małgorzata; Fiszer, Roland; Smerdziński, Sebastian; Gałeczka, Michał; Litwin, Linda

    2018-06-04

    Atrial septal defect type II (ASD), according to current standards, is closed percutaneously usually after the child has reached the age of 4-5 years. There are limited data regarding such treatment in smaller infants. To evaluate feasibility, safety and efficacy of percutaneous ASD closure in children under 3 years of age. Overall group of 149 children < 3 years with hemodynamically significant ASD, who underwent effective transcatheter ASD closure in one tertiary center between 1999 and 2014 were included. Mean procedural age of treated children was 2,2 years and weight 12,5 kg. In all nitinol wire mesh devices were applied (mostly Amplatzer Septal Occluders). ASD was closed by standard technique (except few cases when left disc of implant was inserted initially into right pulmonary vein to prevent oblique position of the device). Complications related to the procedure were divided into major and minor ones. There were 97 children with a single ASD and 52 with double/multiple ASD. No death, no implant embolization, and one major complications occurred during procedure and in follow-up. ASD was completely closed in all but 8 patients with double/multiple ASD. Right ventricle diameter normalization occurred in all during 1 year follow-up. In majority of the patients in follow-up an acceleration of physical development and resolution of accompanying morbidity was observed. Percutaneous ASD device closure can be performer safely in children below 3 years of age with low risk of complication during and after the procedure.

  18. Concomitant surgical closure of left atrial appendage: A systematic review and meta-analysis.

    PubMed

    Ando, Masahiko; Funamoto, Masaki; Cameron, Duke E; Sundt, Thoralf M

    2018-03-12

    Although percutaneous closure of the left atrial appendage is supported as a potential alternative to lifelong anticoagulation in patients with atrial fibrillation, comprehensive evidence on surgical left atrial appendage closure in heart surgery is limited. We conducted a meta-analysis of studies comparing patients who underwent open cardiac surgery with or without left atrial appendage closure. A literature search was performed on PubMed, Embase, and Cochrane Trials databases. Outcomes of interest were 30-day/in-hospital mortality and cerebrovascular accident. I 2 statistics were used to evaluate heterogeneity, and publication bias was evaluated by Begg's and Egger's tests. We reviewed 1284 articles and selected for main analysis 7 articles including 3897 patients (1963 in the left atrial appendage closure group and 1934 in the non-left atrial appendage closure group). Among the 7 studies, 3 were randomized-controlled studies, 3 were propensity-matched studies, and 1 was a case-matching study. At 30-day/in-hospital follow-up, left atrial appendage closure was significantly associated with decreased risk of mortality and cerebrovascular accident (odds ratio, 0.384, 95% confidence interval, 0.233-0.631 for mortality, and odds ratio, 0.622, 95% confidence interval, 0.388-0.998 for cerebrovascular accident). Stratified analysis demonstrated that this association was more prominent in preoperative atrial fibrillation strata. Concomitant surgical left atrial appendage closure should be considered at the time of open cardiac surgery, particularly among those in atrial fibrillation preoperatively. The benefit of left atrial appendage closure for patients not in atrial fibrillation and for those undergoing nonvalvular surgery is still unclear. Further prospective investigations are indicated. Copyright © 2018. Published by Elsevier Inc.

  19. Electric Sail (E-Sail) Tether Team

    NASA Image and Video Library

    2017-08-03

    Electric Sail (E-Sail) Tether Team with 6U CubeSat Prototypes and Current Version of Tether Deployer Test Article, (Right to left: Tom Bryan, Davis Hunter (student intern), Jonathan MacArthur (student intern), Charles Cowen, Mike Tinker)

  20. Percutaneous Coronary Intervention in Severely Calcified Unprotected Left Main Coronary Artery Disease: Initial Experience With Orbital Atherectomy.

    PubMed

    Lee, Michael S; Shlofmitz, Evan; Kaplan, Barry; Shlofmitz, Richard

    2016-04-01

    We report the clinical outcomes of patients who underwent percutaneous coronary intervention (PCI) with orbital atherectomy for severely calcified unprotected left main coronary artery (ULMCA) disease. Although surgical revascularization is the gold standard for patients with ULMCA disease, not all patients are candidates for this. PCI is increasingly used to treat complex coronary artery disease, including ULMCA disease. The presence of severely calcified lesions increases the complexity of PCI. Orbital atherectomy can be used to facilitate stent delivery and expansion in severely calcified lesions. The clinical outcomes of patients treated with orbital atherectomy for severely calcified ULMCA disease have not been reported. From May 2014 to July 2015, a total of 14 patients who underwent PCI with orbital atherectomy for ULMCA disease were retrospectively evaluated. The primary endpoint was major cardiac and cerebrovascular event (cardiac death, myocardial infarction, stroke, and target-lesion revascularization) at 30 days. The mean age was 78.2 ± 5.8 years. The mean ejection fraction was 41.8 ± 19.8%. Distal bifurcation disease was present in 9 of 14 patients. Procedural success was achieved in all 14 patients. The 30-day major adverse cardiac and cerebrovascular event rate was 0%. One patient had coronary dissection that was successfully treated with stenting. No patient had perforation, slow flow, or thrombosis. Orbital atherectomy in patients with severely calcified ULMCA disease is feasible, even in high-risk patients who were considered poor surgical candidates. Randomized trials are needed to determine the role of orbital atherectomy in ULMCA disease.

  1. Open Liver Resection, Laparoscopic Liver Resection, and Percutaneous Thermal Ablation for Patients with Solitary Small Hepatocellular Carcinoma (≤30 mm): Review of the Literature and Proposal for a Therapeutic Strategy.

    PubMed

    Viganò, Luca; Laurenzi, Andrea; Solbiati, Luigi; Procopio, Fabio; Cherqui, Daniel; Torzilli, Guido

    2018-06-11

    Patients with a single hepatocellular carcinoma (HCC) ≤3 cm and preserved liver function have the highest likelihood to be cured if treated. The most adequate treatment methods are yet a matter that is debated. We reviewed the literature about open anatomic resection (AR), laparoscopic liver resection (LLR), and percutaneous thermal ablation (PTA). PTA is effective as resection for HCC < 2 cm, when they are neither subcapsular nor perivascular. PTA in HCC of 2-3 cm is under evaluation. AR with the removal of the tumor-bearing portal territory is recommended for HCC > 2 cm, except for subcapsular ones. In comparison with open surgery, LRR has better short-term outcomes and non-inferior long-term outcomes. LLR is standardized for superficial limited resections and for left-sided AR. According to the available evidences, the following therapeutic proposal can be advanced. Laparoscopic limited resection is the standard for any subcapsular HCC. PTA is the first-line treatment for deep-located HCC < 2 cm, except for those in contact with Glissonean pedicles. Laparoscopic AR is the standard for deep-located HCC of 2-3 cm of the left liver, while open AR is the standard for deep-located HCC of 2-3 cm in the right liver. HCC in contact with Glissonean pedicles should be scheduled for resection (open or laparoscopic) independent of their size. Liver transplantation is reserved to otherwise untreatable patients or as a salvage procedure at recurrence. © 2018 S. Karger AG, Basel.

  2. Percutaneous transesophageal gastro-tubing (PTEG) as an alternative long-term tube feeding procedure when gastrostomy is not feasible

    PubMed Central

    Toh Yoon, Ezekiel Wong; Nishihara, Kazuki

    2017-01-01

    Background: Percutaneous transesophageal gastro-tubing (PTEG) is a minimally invasive technique to access the gut via an esophagostomy. However, this procedure is not well known and the literature available is still fairly limited. This observational study was conducted to evaluate our experience using this method as an alternative long-term tube feeding procedure when gastrostomy is not suitable. Methods: A total of 15 patients (10 males and 5 females) who underwent PTEG at our institution from 2012 to 2016 were observed and analyzed in this study. Results: The average age was 80.1 (71–93) years. Underlying conditions that required PTEG were previous gastric resection in 11 patients, left diaphragm disorder in 2 patients, interposing transverse colon between the abdominal wall and anterior gastric wall in 1 patient, and severe gastrostomy site leakage in 1 patient. Tube placement was successful in all patients by approaching the left side of the neck, using a 15 Fr size tube. The mean postoperative length of stay was 22 (8–48) days. Postoperative adverse events included accidental tube dislodgement in three patients, tracheoesophageal fistula in one patient, inferior thyroid artery injury in one patient and thyroid gland mispuncture in one patient. There was no procedure-related mortality nor mortality at 30 days. Eight patients were discharged with some oral intake. Conclusions: PTEG is feasible in patients requiring long-term tube feeding for whom gastrostomy is unsuitable. It is an effective long-term tube feeding procedure and should be offered as a more comfortable alternative to nasogastric tubing. PMID:29204186

  3. Percutaneous transesophageal gastro-tubing (PTEG) as an alternative long-term tube feeding procedure when gastrostomy is not feasible.

    PubMed

    Toh Yoon, Ezekiel Wong; Nishihara, Kazuki

    2017-12-01

    Percutaneous transesophageal gastro-tubing (PTEG) is a minimally invasive technique to access the gut via an esophagostomy. However, this procedure is not well known and the literature available is still fairly limited. This observational study was conducted to evaluate our experience using this method as an alternative long-term tube feeding procedure when gastrostomy is not suitable. A total of 15 patients (10 males and 5 females) who underwent PTEG at our institution from 2012 to 2016 were observed and analyzed in this study. The average age was 80.1 (71-93) years. Underlying conditions that required PTEG were previous gastric resection in 11 patients, left diaphragm disorder in 2 patients, interposing transverse colon between the abdominal wall and anterior gastric wall in 1 patient, and severe gastrostomy site leakage in 1 patient. Tube placement was successful in all patients by approaching the left side of the neck, using a 15 Fr size tube. The mean postoperative length of stay was 22 (8-48) days. Postoperative adverse events included accidental tube dislodgement in three patients, tracheoesophageal fistula in one patient, inferior thyroid artery injury in one patient and thyroid gland mispuncture in one patient. There was no procedure-related mortality nor mortality at 30 days. Eight patients were discharged with some oral intake. PTEG is feasible in patients requiring long-term tube feeding for whom gastrostomy is unsuitable. It is an effective long-term tube feeding procedure and should be offered as a more comfortable alternative to nasogastric tubing.

  4. Coagulopathy as a complication of kidney biopsies in paediatric systemic lupus erythematosus patients with antiphospholipid syndrome.

    PubMed

    Nagata, Hiroko; Sato, Mai; Ogura, Masao; Yoshikawa, Takahisa; Yamamoto, Kazuna; Matsumura, Sohshi; Kano, Yuji; Saida, Ken; Sako, Mayumi; Kamei, Koichi; Yoshioka, Takako; Ogata, Kentaro; Ito, Shuichi; Ishikura, Kenji

    2018-06-01

    Children with systemic lupus erythematosus (SLE) generally undergo a pretreatment kidney biopsy. However, some of these patients, especially those with antiphospholipid syndrome (APS), may experience serious coagulopathic complications. We report herein two cases of paediatric SLE with APS in which, despite normal blood test results, the disparate coagulopathic complications of haemorrhage and embolism developed following a kidney biopsy. Case 1 was, an 8-year-old male in whom, primary APS was initially diagnosed. Fourteen months later SLE was diagnosed. Based on a percutaneous kidney biopsy, International Society of Nephrology and the Renal Pathology Society (ISN/RPS) class III-A lupus nephritis was histologically diagnosed. On post-biopsy Day 9, a giant haematoma in the fascia of the left kidney developed and was accompanied by changes in the vital signs. Case 2, a 13-year-old male, initially received the diagnosis of SLE with APS and underwent two courses of pulse methylprednisolone therapy. His coagulation abnormalities improved, and a percutaneous needle kidney biopsy was performed, leading to the histological diagnosis of ISN/RPS class III-A lupus nephritis. Furthermore, thrombotic microangiopathy was also detected in the renal histopathology. On post biopsy Day 6, the patient experienced right leg pain. A contrast CT and lower extremity ultrasonography detected a massive deep vein thrombosis and partial left pulmonary artery thrombosis. A kidney biopsy in children with SLE and APS can cause lethal coagulopathic complications, and the risks to such patients should be weighed carefully before the procedure is performed. © 2017 Asian Pacific Society of Nephrology.

  5. Percutaneous ureteral stent placement for the treatment of a benign ureteral obstruction in a Sumatran tiger (Panthera tigris sumatrae).

    PubMed

    Delk, Katie W; Wack, Raymund F; Burgdorf-Moisuk, Anne; Palm, Carrie A; Zwingenberger, Allison; Glaiberman, Craig B; Ferguson, Kenneth H; Culp, William T N

    2015-01-01

    A 15-year-old, 113 kg intact male Sumatran tiger (Panthera tigris sumatrae) was evaluated for weight loss, polydipsia, and intermittent hematuria. The tiger was immobilized for diagnostic testing including blood work, urinalysis, and abdominal ultrasound. Laboratory testing demonstrated macro- and microhematuria, azotemia, and an increased urine protein:creatinine ratio. Abdominal ultrasound revealed bilateral ureterolithiasis as well as hydronephrosis and ureteral dilation. Ultrasonography performed 5 months later revealed worsening of the right-sided hydronephrosis and hydroureter and a decrease in the severity of dilation on the left side presumably from passage of the left-sided ureteral calculi. Nephroureteral decompression via the placement of a stent was elected. A pigtail ureteral catheter (8.2 French diameter) was placed in the right ureter via an antegrade percutaneous approach utilizing ultrasound and fluoroscopic-guidance. Following stent placement, macrohematuria resolved although microhematuria was noted in opportunistic urine samples. Five months after stent placement, the azotemia had mildly progressed, the urine protein:creatinine ratio was improved, the right hydronephrosis and hydroureter had completely resolved, and the ureteral stent remained in the appropriate position. The tiger had clinically improved with a substantial increase in appetite, weight, and activity level. Ureteral stenting allowed for nephroureteral decompression in the captive large felid of this report, and no complications were encountered. Ureteral stenting provided a minimally invasive method of managing ureteral obstruction in this patient and could be considered in future cases due to the clinical improvement and low morbidity. © 2015 Wiley Periodicals, Inc.

  6. Coronary artery bypass grafting in octogenarians: only when percutaneous coronary intervention is not feasible?

    PubMed

    Nicolini, Francesco

    2015-11-01

    The aim of this study was to review recent literature reporting the results of coronary revascularization by percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG) in patients older than 80 years. The review of recent studies on octogenarians demonstrates a surgical CABG advantage in the case of patients with increasing baseline coronary risk, such as severe multivessel disease, chronic total occlusions, and left ventricular dysfunction. PCI seems to be more appropriate for less severe degree and distribution of coronary lesions, and for subgroups of patients with higher surgical risk, such as acute coronary syndromes, reoperations, malignancy, dementia, poor mobility, frailty, and serious comorbidities contraindicating extracorporeal circulation. It is not the case that CABG is indicated only when there are contraindications to PCI. CABG confers more benefit than PCI in patients with increasing baseline cardiac risk, in the absence of serious systemic diseases that can reasonably reduce their life expectancy.CABG and PCI, with proper selection, should be considered complementary rather than competitive procedures in the therapy of octogenarians affected by coronary artery disease.

  7. Hepatic parenchymal atrophy induction for intractable segmental bile duct injury after liver resection.

    PubMed

    Hwang, Shin; Park, Gil-Chun; Ha, Tae-Yong; Ko, Gi-Young; Gwon, Dong-Il; Choi, Young-Il; Song, Gi-Won; Lee, Sung-Gyu

    2012-05-01

    Liver resection can result in various types of bile duct injuries but their treatment is usually difficult and often leads to intractable clinical course. We present an unusual case of hepatic segment III duct (B3) injury, which occurred after left medial sectionectomy for large hepatocellular carcinoma and was incidentally detected 1 week later due to bile leak. Since the pattern of this B3 injury was not adequate for operative biliary reconstruction, atrophy induction of the involved hepatic parenchyma was attempted. This treatment consisted of embolization of the segment III portal branch to inhibit bile production, induction of heavy adhesion at the bile leak site and clamping of the percutaneous transhepatic biliary drainage (PTBD) tube to accelerate segment III atrophy. This entire procedure, from liver resection to PTBD tube removal took 4 months. This patient has shown no other complication or tumor recurrence for 4 years to date. These findings suggest that percutaneous segmental portal vein embolization, followed by intentional clamping of external biliary drainage, can effectively control intractable bile leak from segmental bile duct injury.

  8. Applications of laser in ischemic heart disease in China

    NASA Astrophysics Data System (ADS)

    Chen, Mingzhe; Zhang, Yongzhen

    1999-09-01

    Current data demonstrate that laser coronary angioplasty is most useful in complex lesions not well suited for percutaneous transluminal coronary angioplasty (PTCA). It is not `stand-alone' procedure, and should be considered an adjunct to PTCA or stenting. To date, there are not data supporting reduction of restenosis. Direct myocardial revascularization (DMR), either transmyocardial revascularization (TMR) or percutaneous (catheter-based) myocardial revascularization (PMR), uses laser to create channels between ischemic myocardium and left ventricular cavity. Candidates include patients with chronic, severe, refractory angina and those unable to undergo angioplasty or bypass surgery because conduits or acceptable target vessels are lacking. Although the mechanisms of action of DMR have not yet been clearly elucidated, but several theories have been proposed, including channel patency, angiogenesis, and denervation. TMR, typically requiring open thoracotomy, is effective for improving myocardial perfusion and reducing angina. Pilot studies demonstrate that clinical application of PMR is feasible and safe and effective for decreasing angina. Late sequelae also remain to be determined. An ongoing randomized clinical trial is comparing PMR with conventional medical therapy in patients with severe, refractory angina and disease unamenable to angioplasty or bypass surgery.

  9. The Cost-Effectiveness of Surgical Fixation of Distal Radial Fractures: A Computer Model-Based Evaluation of Three Operative Modalities.

    PubMed

    Rajan, Prashant V; Qudsi, Rameez A; Dyer, George S M; Losina, Elena

    2018-02-07

    There is no consensus on the optimal fixation method for patients who require a surgical procedure for distal radial fractures. We used cost-effectiveness analyses to determine which of 3 modalities offers the best value: closed reduction and percutaneous pinning, open reduction and internal fixation, or external fixation. We developed a Markov model that projected short-term and long-term health benefits and costs in patients undergoing a surgical procedure for a distal radial fracture. Simulations began at the patient age of 50 years and were run over the patient's lifetime. The analysis was conducted from health-care payer and societal perspectives. We estimated transition probabilities and quality-of-life values from the literature and determined costs from Medicare reimbursement schedules in 2016 U.S. dollars. Suboptimal postoperative outcomes were determined by rates of reduction loss (4% for closed reduction and percutaneous pinning, 1% for open reduction and internal fixation, and 11% for external fixation) and rates of orthopaedic complications. Procedural costs were $7,638 for closed reduction and percutaneous pinning, $10,170 for open reduction and internal fixation, and $9,886 for external fixation. Outputs were total costs and quality-adjusted life-years (QALYs), discounted at 3% per year. We considered willingness-to-pay thresholds of $50,000 and $100,000. We conducted deterministic and probabilistic sensitivity analyses to evaluate the impact of data uncertainty. From the health-care payer perspective, closed reduction and percutaneous pinning dominated (i.e., produced greater QALYs at lower costs than) open reduction and internal fixation and dominated external fixation. From the societal perspective, the incremental cost-effectiveness ratio for closed reduction and percutaneous pinning compared with open reduction and internal fixation was $21,058 per QALY and external fixation was dominated. In probabilistic sensitivity analysis, open reduction and internal fixation was cost-effective roughly 50% of the time compared with roughly 45% for closed reduction and percutaneous pinning. When considering data uncertainty, there is only a 5% to 10% difference in the frequency of probability combinations that find open reduction and internal fixation to be more cost-effective. The current degree of uncertainty in the data produces difficulty in distinguishing either strategy as being more cost-effective overall and thus it may be left to surgeon and patient shared decision-making. Economic Level III. See Instructions for Authors for a complete description of levels of evidence.

  10. Recurrent syncope attributed to left main coronary artery severe stenosis.

    PubMed

    Li, Min; Zheng, Xinyi; Liu, Hua; Liu, Yujie

    2015-01-01

    Patients with acute coronary syndrome (ACS) rarely manifest as recurrent syncope due to malignant ventricular arrhythmia. We report a case of a 56-year-old Chinese male with complaints of paroxysmal chest burning sensation and distress for 2 weeks as well as loss of consciousness for 3 days. The electrocardiogram (ECG) revealed paroxysmal multimorphologic ventricular tachycardia during attack and normal heart rhythm during intervals. Coronary angiograph showed 90% stenosis in left main coronary artery and 80% stenosis in anterior descending artery. Two stents sized 4.0∗18 mm and 2.75∗18 mm were placed at left main coronary artery and anterior descending artery, respectively, during percutaneous coronary intervention (PCI). The patient was discharged and never had ventricular arrhythmia again during a 3-month follow-up since the PCI. This indicated that ventricular tachycardia was correlated with persistent severe myocardial ischemia. Coronary vasospasm was highly suspected to be the reason of the sudden attack and acute exacerbation. PCI is recommended in patients with both severe coronary artery stenosis and ventricular arrhythmia. Removing myocardial ischemia may stop or relieve ventricular arrhythmia and prevent cardiac arrest.

  11. Percutaneous Occlusion of the Left Atrial Appendage with the Watchman Device in an Active Duty Sailor with Atrial Fibrillation and Recurrent Thromboembolism Despite Appropriate Use of Oral Anticoagulation.

    PubMed

    Cox, Justin M; Choi, Anthony J; Oakley, Luke S; Francisco, Gregory M; Nayak, Keshav R

    2018-05-23

    Atrial fibrillation is the most common significant cardiac arrhythmia and is associated with a five-fold increased risk of stroke from thromboembolism. Over 94% of these emboli arise from the left atrial appendage. Systemic embolic phenomena are rare, accounting for less than 1 out of 10 of all embolic events, but have a similar prevention strategy. Anticoagulation significantly reduces the risk of these events, and thus forms the cornerstone of therapy for most patients with atrial fibrillation. Left atrial appendage occlusion with the Watchman device is a recently approved alternative for stroke prevention in selected patients. We present a case of an active duty U.S. Navy sailor at low risk for thromboembolism who nonetheless suffered recurrent thromboembolic events despite appropriate anticoagulation, and thus underwent Watchman implantation. The therapy in this case will ideally provide a lifetime of protection from recurrent systemic embolization while allowing the patient to continue his active duty military career without restriction due to oral anticoagulation.

  12. Aneurysmal coronary cameral fistula

    PubMed Central

    Jamil, Gohar; Khan, Asad; Malik, Azhar; Qureshi, Anwer

    2013-01-01

    A 26-year-old asymptomatic man, being medically managed for ventricular septal defect since childhood, presented to the outpatient clinic for a second opinion. Clinically, he was well built with normal vital signs. Cardiac auscultation was significant for a diastolic murmur over the praecordium. An ECG showed non-specific ST changes, and a subsequent transthoracic echocardiography performed revealed diastolic flow from the left ventricular (LV) anteroseptal wall into the LV cavity. A diagnosis of coronary–cameral fistula was confirmed by a multidetector CT which showed a 2.5×2 cm aneurysmal left anterior descending artery fistula to the LV. In addition to starting aspirin, transcatheter closure with occlusion device was considered knowing the potential risk of thrombus formation in the aneurysm and subsequent systemic embolisation. The patient however refused any percutaneous or surgical intervention. He remains asymptomatic 1 year after returning to his home country. PMID:23737570

  13. Emerging Transcatheter Options for Tricuspid Regurgitation

    PubMed Central

    Kalra, Ankur; Uberoi, Angad S.; Latib, Azeem; Khera, Sahil; Little, Stephen H.; Bhatt, Deepak L.; Reardon, Michael J.; Kleiman, Neal S.; Barker, Colin M.

    2017-01-01

    Tricuspid regurgitation (TR) presents as either primary valve pathology or secondary to pulmonary or left-sided heart disease. Severe TR portends a worse prognosis independent of age, right ventricular size and function, severe left ventricular dysfunction, and increased pulmonary arterial pressures. Surgical treatment for TR has mostly been limited to patients undergoing mitral valve repair since those at high surgical risk are not candidates for traditional TR surgery. For these patients, minimally invasive techniques could be of great benefit, yet these techniques have been slow to develop because of the various anatomic and physiological aspects of the tricuspid valve apparatus. Several promising new techniques are currently undergoing clinical investigation, including caval valve implantation, percutaneous tricuspid annuloplasty techniques (Trialign, TriCinch, Cardioband), edge-to-edge repair with the MitraClip system, the FORMA device, and the GATE tricuspid Atrioventricular Valved Stent. Further evaluation of their safety and long-term efficacy is warranted prior to commercial approval and widespread adoption. PMID:29743996

  14. Best way to revascularize patients with main stem and three-vessel lesions. Patients should be operated!

    PubMed

    Reichenspurner, H; Conradi, L; Cremer, J; Mohr, F W

    2010-09-01

    Despite established guidelines for the treatment of coronary artery disease (CAD) by either coronary artery bypass grafting (CABG) or percutaneous coronary intervention (PCI), everyday clinical practice has proven to differ substantially with even the most complex coronary lesions being targeted by PCI today. However, an abundancy of clinical trials, both observational and randomized has proven the superiority of coronary surgery over PCI in almost every type of multivessel or left main CAD in symptomatic patients. This holds true also for 'hard' endpoints like cardiac death or myocardial infarction as recently demonstrated by the landmark SYNTAX trial. These results have lead to the wording of appropriateness criteria, which integrate current guidelines, evidence from clinical trials and interdisciplinary expert opinion and which express essentially the same message as the SYNTAX trial: "CABG remains the standard of care for patients with three-vessel or left main coronary artery disease"

  15. Covered stent to exclude intravascular thrombus.

    PubMed

    Liistro, Francesco; Stankovic, Goran; Di Mario, Carlo; Montorfano, Matteo; Briguori, Carlo; Colombo, Antonio

    2002-04-01

    To describe the utility of stent-graft implantation to avoid distal embolization from a large thrombus-containing lesion. A 67-year-old man was evaluated for recent onset of disabling left leg claudication. Angiography disclosed a mobile lobular mass occluding the left common iliac artery; irregular staining suggested an atherothrombotic lesion. Through a percutaneous ipsilateral access and an 8-F sheath, a balloon-expandable Jostent peripheral stent-graft was positioned with the distal edge immediately proximal to the internal iliac artery ostium. A prominent "waist" at the center of the balloon confirmed entrapment of the thrombotic mass. Completion angiography showed an optimal result with no residual stenosis or evidence of distal embolization. At 6-month follow-up, the patient was asymptomatic with angiographically documented luminal patency and no evidence of in-stent stenosis. Stent-graft implantation appears a viable treatment alternative for thrombus-containing lesions, particularly when the thrombotic material is localized or is in a large vessel.

  16. Page Kidney in Wunderlich Syndrome Causing Acute Renal Failure and Urosepsis: Successful Timely Minimally Invasive Management of a Devastating Clinical Entity.

    PubMed

    Vijayganapathy, Sundaramoorthy; Karthikeyan, Vilvapathy Senguttuvan; Mallya, Ashwin; Sreenivas, Jayaram

    2017-06-01

    Wunderlich Syndrome (WS) is an uncommon condition where acute onset of spontaneous bleeding occurs into the subcapsular and perirenal spaces. It can prove fatal if not recognized and treated aggressively at the appropriate time. A 32-year-old male diagnosed elsewhere as acute renal failure presented with tender left loin mass, fever and hypovolemic shock with serum creatinine 8.4 mg/dl. He was started on higher antibiotics and initiated on haemodialysis. Ultrasonogram (USG), Non-Contrast Computed Tomography (NCCT) and Magnetic Resonance Imaging (MRI) showed bilateral perirenal subcapsular haematomas - right 3.6 x 3.1 cm and left 10.3 x 10.3 cm compressing and displacing left kidney, fed by capsular branch of left renal artery on CT angiogram. Initial aspirate was bloody but he persisted to have febrile spikes, renal failure and urosepsis and he was managed conservatively. Repeat NCCT 10 days later revealed left perinephric abscess and Percutaneous Drainage (PCD) was done. Patient improved, serum creatinine stabilized at 2 mg/dl without haemodialysis and PCD was removed after two weeks. To conclude, bilateral idiopathic spontaneous retroperitoneal haemorrhage with renal failure is a rare presentation. This case highlights the need for high index of suspicion, the role of repeated imaging and successful minimally invasive management with timely PCD and supportive care.

  17. Minimally invasive or interventional repair of atrial septal defects in children: experience in 171 cases and comparison with conventional strategies.

    PubMed

    Formigari, R; Di Donato, R M; Mazzera, E; Carotti, A; Rinelli, G; Parisi, F; Pasquini, L; Ballerini, L

    2001-05-01

    The goal of this study was to evaluate percutaneous interventional and minimally invasive surgical closure of secundum atrial septal defect (ASD) in children. Concern has surrounded abandoning conventional midline sternotomy in favor of the less invasive approaches pursuing a better cosmetic result and a more rational resource utilization. A retrospective analysis was performed on the patients treated from June 1996 to December 1998. One hundred seventy-one children (median age 5.8 years, median weight 22.1 kg) underwent 52 device implants, 72 minimally invasive surgical operations and 50 conventional sternotomy operations. There were no deaths and no residual left to right shunt in any of the groups. The overall complication rate causing delayed discharge was 12.6% for minimally invasive surgery, 12.0% for midline sternotomy and 3.8% for transcatheter device closure (p < 0.01). The mean hospital stay was 2.8 +/- 1.0 days, 6.5 +/- 2.1 days and 2.1 +/- 0.5 days (p < 0.01); the skin-to-skin time was 196 +/- 43 min, 163 +/- 46 min and 118 +/- 58 min, respectively (p < 0.001). Extracorporeal circulation time was 49.9 +/- 10.1 min in the minithoracotomy group versus 37.2 +/- 13.8 min in the sternotomy group (p < 0.01) but without differences in aortic cross-clamping time. Sternotomy was the most expensive procedure (15,000 EUR +/- 1,050 EUR vs. 12,250 EUR +/- 472 EUR for minithoracotomy and 13,000 EUR +/- 300 EUR for percutaneous devices). While equally effective compared with sternotomy, the cosmetic and financial appeal of the percutaneous and minimally invasive approaches must be weighed against their greater exposure to technical pitfalls. Adequate training is needed if a strategy of surgical or percutaneous minimally invasive closure of ASD in children is planned in place of conventional surgery.

  18. Changes in left ventricular ejection fraction and coronary flow reserve after coronary microembolization

    PubMed Central

    Ma, Jianying; Qian, Juying; Zeng, Xin; Sun, Aijun; Chang, Shufu; Chen, Zhangwei; Zou, Yunzeng

    2012-01-01

    Introduction Although coronary microembolization (CME) is a frequent phenomenon in patients undergoing percutaneous coronary intervention, few data are available on the changes in left ventricular ejection fraction (LVEF) and coronary flow reserve (CFR) after CME. Material and methods In this study, six miniature swine of either sex (body weight 21-25 kg) were used to prepare a CME model. After coronary angiography, 1.2 × 105 microspheres (42 µm) were selectively infused into the left anterior descending artery via an infusion catheter. Left ventricular ejection fraction was evaluated using transthoracic echocardiography; myocardial blood flow was measured using coloured microspheres; and CFR and coronary pressure were measured using Doppler and a pressure wire. Results Left ventricular ejection fraction was 0.77 ±0.08 at baseline, 0.69 ±0.08 at 2 h, 0.68 ±0.08 at 6 h, and 0.76 ±0.06 at 1 week (2 h vs. baseline p < 0.05; 6 h vs. baseline p < 0.01). After CME, left ventricular end systolic volume (LVESV) and end diastolic volume (LVEDV) were significant larger 1 week later (p < 0.01 for both), while CFR was significantly reduced at 6 h (1.24 ±0.10 at 6 h vs. 1.77 ±0.30 at baseline, p < 0.01) and myocardial blood flow remained unchanged. Serum ET-1 level was significantly higher only at 6 h after CME (6 h vs. baseline p < 0.05). Conclusions Reduction of CFR and LVEF is significant at 6 h after CME and recovers 1 week later with left ventricular dilation. PMID:22457677

  19. Elective percutaneous coronary intervention without on-site surgical backup: a community hospital experience.

    PubMed

    Djelmami-Hani, M; Mouanoutoua, Mouatou; Hashim, Abdelazim; Solis, Joaquin; Bergen, Lawrence; Oldridge, Neil; Egbujiobi, Leo C; Allaqaband, Suhail; Akhtar, Masood; Bajwa, Tanvir

    2007-12-01

    The American College of Cardiology guidelines consider elective percutaneous coronary intervention (PCI) without on-site surgical backup (OSB) a Class-III indication. Our objective was to determine the safety of elective PCI without OSB. The study is a prospective analysis of a cohort of patients who underwent elective PCI without OSB at our institution. All patients were at our community satellite institution in Beloit, Wis. Three hundred twenty-one elective interventions were performed (mean age 64 +/-12, 68% male). The prevalence of diabetes and hypertension was 28% and 82.5% respectively. A predefined protocol was designed to transfer patients to a cardiac surgical facility if necessary. An experienced interventional cardiologist reviewed the diagnostic angiograms. Patients with complex lesions were excluded from the study. Any procedure-related death or emergency coronary artery bypass graft surgery. Three hundred eighty-two vessels were stented. Multi-vessel intervention was performed in 61 patients (19%). Only 5% of lesions were type C. Four hundred thirty-seven stents were deployed. IIb-IIIa inhibitors were used in 77 (24%) cases. Procedural success was 99.7%. There were no deaths, myocardial infarctions nor need for urgent target vessel revascularization at 6 months. With careful patient/lesion selection, an experienced interventional cardiologist and a predefined transfer protocol, elective PCI without OSB can be performed safely.

  20. The influence of naturalistic, directionally non-specific motion on the spatial deployment of visual attention in right-hemispheric stroke.

    PubMed

    Cazzoli, Dario; Hopfner, Simone; Preisig, Basil; Zito, Giuseppe; Vanbellingen, Tim; Jäger, Michael; Nef, Tobias; Mosimann, Urs; Bohlhalter, Stephan; Müri, René M; Nyffeler, Thomas

    2016-11-01

    An impairment of the spatial deployment of visual attention during exploration of static (i.e., motionless) stimuli is a common finding after an acute, right-hemispheric stroke. However, less is known about how these deficits: (a) are modulated through naturalistic motion (i.e., without directional, specific spatial features); and, (b) evolve in the subacute/chronic post-stroke phase. In the present study, we investigated free visual exploration in three patient groups with subacute/chronic right-hemispheric stroke and in healthy subjects. The first group included patients with left visual neglect and a left visual field defect (VFD), the second patients with a left VFD but no neglect, and the third patients without neglect or VFD. Eye movements were measured in all participants while they freely explored a traffic scene without (static condition) and with (dynamic condition) naturalistic motion, i.e., cars moving from the right or left. In the static condition, all patient groups showed similar deployment of visual exploration (i.e., as measured by the cumulative fixation duration) as compared to healthy subjects, suggesting that recovery processes took place, with normal spatial allocation of attention. However, the more demanding dynamic condition with moving cars elicited different re-distribution patterns of visual attention, quite similar to those typically observed in acute stroke. Neglect patients with VFD showed a significant decrease of visual exploration in the contralesional space, whereas patients with VFD but no neglect showed a significant increase of visual exploration in the contralesional space. No differences, as compared to healthy subjects, were found in patients without neglect or VFD. These results suggest that naturalistic motion, without directional, specific spatial features, may critically influence the spatial distribution of visual attention in subacute/chronic stroke patients. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Malignancy Associated Iatrogenic Iliopsoas Abscess -Venous Access Complication From Ablation Procedure.

    PubMed

    Iskandar, Sandia; Atoui, Moustapha; Rizwan Afzal, Muhammad; Lavu, Madhav; Reddy, Madhu; Lakkireddy, Dhanunjaya

    2016-01-01

    Iliopsoas abscess is a rare condition with a high rate of mortality and morbidity if left untreated. It can occur from hematogenous or lymphatic spread from distant structures or as a result of contiguous spread from adjacent structures. The disease typically occurs in patients with immunocompromised status and the symptoms can be non-specific.1,2 Generally, infectious complications from venous access during atrial fibrillation (AF) procedure are uncommon, and an iatrogenic iliopsoas abscess from percutaneous cardiac procedures has never been reported. We present the first case of iliopsoas abscess from an ablation procedure.

  2. Successful treatment of a congenital pulmonic valvular stenosis in a snow leopard (Uncia uncia) by percutaneous balloon valvuloplasty.

    PubMed

    Chai, Norin; Behr, Luc; Chetboul, Valérie; Pouchelon, Jean Louis; Wedlarski, Rudy; Tréhiou-Sechi, Emilie; Gouni, Vassiliki; Misbach, Charlotte; Petit, Amandine M P; Bourgeois, Aude; Hazan, Thierry; Borenstein, Nicolas

    2010-12-01

    A 3-yr-old intact female snow leopard (Uncia uncia) was evaluated for progressive apathy, lethargy, and decreased appetite. Cardiac auscultation revealed a left basal grade IV/VI systolic ejection murmur, and an echocardiogram confirmed a severe pulmonic valvular stenosis (pressure gradient of 98 mm Hg). The lesion was managed by balloon valvuloplasty, resulting in a marked pressure gradient reduction (30 mm Hg). The cat recovered well, and clinical signs resolved. This is the first description of a pulmonary valve stenosis and management with balloon valvuloplasty in a wild felid.

  3. Successful Resection and Vascular Ligation of a Large Hepatic Artery Aneurysm - A Case Report and Literature Review.

    PubMed

    Bacalbasa, Nicolae; Brezean, Iulian; Anghel, Claudiu; Barbu, Ion; Pautov, Mihai; Balescu, Irina; Brasoveanu, Vladislav

    2017-01-01

    The occurrence of hepatic artery aneurysms is rare and might be incidentally diagnosed, as the patient remains asymptomatic for a long period of time. However, due to the fact that these lesions are associated with a high risk of developing life threatening complications, such as intraperitoneal rupture, it has been stated that all cases should be submitted to treatment by endovascular or surgical approach. We present the case of a 68-year-old patient, who presented with recurrent upper digestive tract bleedings and was diagnosed with a large aneurysm of the common and the proper hepatic artery, and the gastroduodenal artery. The preoperative angiography revealed an anatomic variation consisting of the common hepatic artery originating from the celiac trunk, and the left hepatic artery originating from the left gastric artery. A percutaneous right portal vein embolization was performed in order to induce hypertrophy of the left lobe and prepare the patient for a right hepatectomy and aneurysmal resection. However, at the time of surgery, after performing the aneurysmal resection and arterial ligation, the vascular supply of the entire liver was efficiently provided by the left hepatic artery and its collaterals. Concluding, hepatic resection was no longer necessary. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  4. Successful Resection and Vascular Ligation of a Large Hepatic Artery Aneurysm – A Case Report and Literature Review

    PubMed Central

    BACALBASA, NICOLAE; BREZEAN, IULIAN; ANGHEL, CLAUDIU; BARBU, ION; PAUTOV, MIHAI; BALESCU, IRINA; BRASOVEANU, VLADISLAV

    2017-01-01

    The occurrence of hepatic artery aneurysms is rare and might be incidentally diagnosed, as the patient remains asymptomatic for a long period of time. However, due to the fact that these lesions are associated with a high risk of developing life threatening complications, such as intraperitoneal rupture, it has been stated that all cases should be submitted to treatment by endovascular or surgical approach. We present the case of a 68-year-old patient, who presented with recurrent upper digestive tract bleedings and was diagnosed with a large aneurysm of the common and the proper hepatic artery, and the gastroduodenal artery. The preoperative angiography revealed an anatomic variation consisting of the common hepatic artery originating from the celiac trunk, and the left hepatic artery originating from the left gastric artery. A percutaneous right portal vein embolization was performed in order to induce hypertrophy of the left lobe and prepare the patient for a right hepatectomy and aneurysmal resection. However, at the time of surgery, after performing the aneurysmal resection and arterial ligation, the vascular supply of the entire liver was efficiently provided by the left hepatic artery and its collaterals. Concluding, hepatic resection was no longer necessary. PMID:28882969

  5. [Pedal bypass using venous allograft].

    PubMed

    Pluháčková, H; Staffa, R; Konečný, Z; Kříž, Z; Vlachovský, R

    Pedal or distal crural bypass surgery for limb salvage is a method with very good long-term results. For patients in whom a suitable autologous venous graft is not available, the use of a venous allograft is an alternative procedure. A 68 years old man with ischaemic disease of lower extremities and gangrene of the left foot was admitted to our Centre in August 2014. He underwent percutaneous transluminal angioplasty of crural arteries of his left lower extremity. This, however, failed to improve peripheral circulation. The patient was then indicated for pedal or distal crural vascular reconstruction. Since no suitable autologous vein was available, distal bypass surgery using a donor graft remained the only option for limb salvage. Amputation of the toes on the left foot due to gangrene was necessary. Subsequently, femoro-pedal bypass to the left common plantar artery was performed using a great saphenous vein allograft. The post-operative course was without complications, the pedal bypass was patent and toe amputation was with good healing. The patient remained in follow-up care. A good outcome of vascular reconstruction with an allograft depends on the availability of a suitable allograft and good patient compliance with post-operative care. In the case presented here, the pedal bypass grafting by means of an allograft helped to save the patients limb. pedal bypass venous allograft limb salvage.

  6. Flow Rate Through Pigtail Catheter Used for Left Heart Decompression in an Artificial Model of Extracorporeal Membrane Oxygenation Circuit.

    PubMed

    Kim, Won Ho; Hong, Tae Hee; Byun, Joung Hun; Kim, Jong Woo; Kim, Sung Hwan; Moon, Sung Ho; Park, Hyun Oh; Choi, Jun Young; Yang, Jun Ho; Jang, In Seok; Lee, Chung Eun; Yun, Jeong Hee

    In refractory cardiogenic shock, veno-arterial extracorporeal membrane oxygenation (ECMO) can be initiated. Although left heart decompression can be accomplished by insertion of a left atrial (LA) or left ventricular (LV) cannula using a percutaneous pigtail catheter, the venting flow rate according to catheter size and ECMO flow rate is unknown. We developed an artificial ECMO circuit. One liter saline bag with its pressure set to 20 mm Hg was connected to ECMO to mimic LV failure. A pigtail catheter was inserted into the 1 L saline bag to simulate LV unloading. For each pigtail catheter size (5-8 Fr) and ECMO flow rate (2.0-4.0 L/min), the moving distance of an air bubble that was injected through a three-way stopcock was measured in the arterial pressure line between the pigtail catheter and ECMO inflow limb. The flow rate was then calculated. We obtained the following equation to estimate the pigtail catheter flow rate.Pigtail vent catheter flow rate (ml/min) = 8×ECMOflow rate(L /min)+9×pigtail catheter size(Fr)- 57This equation would aid in designing of a further study to determine optimal venting flow rate. To achieve optimal venting flow, our equation would enable selection of an adequate catheter size.

  7. Space Shuttle Projects

    NASA Image and Video Library

    1983-11-08

    The crew assigned to the STS-41B (STS-11) mission included (seated left to right) Vance D. Brand, commander; and Robert L. Gibson, pilot. Standing left to right are mission specialists Robert L. Stewart, Ronald E. McNair, and Bruce McCandless. Launched aboard the Space Shuttle Challenger on February 3, 1984 at 8:00:00 am (EST), the STS-41B mission marked the first untethered space walks which were performed by McCandless and Stewart. The crew deployed the WESTAR-VI and PALAPA-B2 satellites.

  8. Interventional cardiology audit report for 2011.

    PubMed

    Baker, L

    2012-10-01

    In 2011 there were 658 percutaneous coronary intervention cases performed with more than 60% of the patients presenting to the hospital as an acute coronary syndrome. Most procedures consisted of balloon dilatation followed by stent deployment, and 93% of these stents were drug-eluting stents. Procedural success was achieved in 93.3% of cases and an overall major adverse cardiac events rate of 3.6%. This includes a mortality rate of (0.5%). In addition, there were 25 Core Valve procedures carried out. This is more than twice the amount of patients who had a transcatheter aortic valve implantation in 2010, reflecting the changing direction of the management of structural heart disease. © 2012 The Author; Internal Medicine Journal © 2012 Royal Australasian College of Physicians.

  9. Pathfinder Rear Ramp

    NASA Image and Video Library

    1997-07-06

    NASA's Mars Pathfinder's rear rover ramp can be seen successfully unfurled in this image, taken at the end of Sol 2 by the Imager for Mars Pathfinder (IMP). This ramp was later used for the deployment of the microrover Sojourner, which occurred at the end of Sol 2. Areas of a lander petal and deflated airbag are visible at left. The image helped Pathfinder scientists determine that the rear ramp was the one to use for rover deployment. At upper right is the rock dubbed "Barnacle Bill," which Sojourner will later study. http://photojournal.jpl.nasa.gov/catalog/PIA00627

  10. Contemporary trends in cardiogenic shock: Incidence, intra-aortic balloon pump utilisation and outcomes from the London Heart Attack Group.

    PubMed

    Rathod, Krishnaraj S; Koganti, Sudheer; Iqbal, M Bilal; Jain, Ajay K; Kalra, Sundeep S; Astroulakis, Zoe; Lim, Pitt; Rakhit, Roby; Dalby, Miles C; Lockie, Tim; Malik, Iqbal S; Knight, Charles J; Whitbread, Mark; Mathur, Anthony; Redwood, Simon; MacCarthy, Philip A; Sirker, Alexander; O'Mahony, Constantinos; Wragg, Andrew; Jones, Daniel A

    2018-02-01

    Cardiogenic shock remains a major cause of morbidity and mortality in patients with ST-segment elevation myocardial infarction. We aimed to assess the current trends in cardiogenic shock management, looking specifically at the incidence, use of intra-aortic balloon pump therapy and outcomes in patients with ST-segment elevation myocardial infarction treated with primary percutaneous coronary intervention. We undertook an observational cohort study of 21,210 ST-segment elevation myocardial infarction patients treated between 2005-2015 at the eight Heart Attack Centres in London, UK. Patients' details were recorded at the time of the procedure into local databases using the British Cardiac Intervention Society percutaneous coronary intervention dataset. There were 1890 patients who presented with cardiogenic shock. The primary outcome was all-cause mortality at a median follow-up of 4.1 years (interquartile range: 2.2-5.8 years). Increasing rates of cardiogenic shock were seen over the course of the study with consistently high mortality rates of 45-70%. A total of 685 patients underwent intra-aortic balloon pump insertion during primary percutaneous coronary intervention for cardiogenic shock with decreasing rates over time. Those patients undergoing intra-aortic balloon pump therapy were younger, more likely to have poor left ventricular function and less likely to have had previous percutaneous coronary intervention compared to the control group. Procedural success rates were similar (86.0% vs 87.1%, p=0.292) although crude, in-hospital major adverse cardiac event rates were higher (43.8% vs 33.7%, p<0.0001) in patients undergoing intra-aortic balloon pump therapy. Kaplan-Meier analysis demonstrated significantly higher mortality rates in patients receiving intra-aortic balloon pump therapy (50.9% intra-aortic balloon pump vs 39.9% control, p<0.0001) during the follow-up period. After multivariate Cox analysis (hazard ratio 1.04, 95% confidence interval 0.62-1.89) and the use of propensity matching (hazard ratio: 1.29, 95% confidence interval: 0.68-1.45) intra-aortic balloon pump therapy was not associated with mortality. Cardiogenic shock treated by percutaneous coronary intervention is increasing in incidence and remains a condition associated with high mortality and limited treatment options. Intra-aortic balloon pump therapy was not associated with a long-term survival benefit in this cohort and may be associated with increased early morbidity.

  11. Impact of very high pressure stent deployment on angiographic and long-term clinical outcomes in true coronary bifurcation lesions treated by the mini-crush stent technique: A single center experience.

    PubMed

    Gerbay, Antoine; Terreaux, Jeremy; Cerisier, Alexis; Vola, Marco; Isaaz, Karl

    Percutaneous coronary intervention (PCI) for bifurcation lesions (BL) using 2 stents technique is known to be associated with high rates of procedural failure especially on the side branch (SB) mainly due to stent incomplete apposition. Stent deployment at very high pressure (SDHP) may lead to better stent expansion and apposition. However, SDHP may also be at the origin of deeper wall injury resulting into major cardiac adverse events. No data are available on evaluation of SDHP in BL treated by a mini-crush stent technique. One hundred and thirteen consecutive patients underwent PCI for BL (Medina 1, 1, 1) using a mini-crush stent technique with SDHP defined as ≥20atm. An angiographic follow-up was performed at 6 month and clinical follow-up was obtained at a median of 3 years. Stent deployment mean pressures were 20±1.4atm (range 20-25) in the main vessel (MV) and 20±1.5atm (range 20-25) in SB. Simultaneous final kissing balloon was used in 92% of cases. PCI was successful in 100%. Angiographic follow-up was obtained in 83% of patients. Restenosis rate was 13% (12% restenosis in the SB) with only one case (0.8%) of SB probable thrombosis. Another case of late stent thrombosis occurred at a 3 years clinical follow-up. Compared with previously published studies in which stents were deployed at lower pressure, SDHP does not increase the restenosis rate in BL using mini-crush stent technique but seems to reduce the rate of stent thrombosis. Copyright © 2016 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  12. Paclitaxel-eluting versus sirolimus-eluting stents in diabetes mellitus: a report from the National Heart, Lung, and Blood Institute Dynamic Registry.

    PubMed

    Wolf, William M; Vlachos, Helen A; Marroquin, Oscar C; Lee, Joon S; Smith, Conrad; Anderson, William D; Schindler, John T; Holper, Elizabeth M; Abbott, J Dawn; Williams, David O; Laskey, Warren K; Kip, Kevin E; Kelsey, Sheryl F; Mulukutla, Suresh R

    2010-02-01

    Diabetes is a powerful predictor of adverse events in patients undergoing percutaneous coronary intervention. Drug-eluting stents reduce restenosis rates compared with bare metal stents; however, controversy remains regarding which drug-eluting stents provides greater benefit in patients with diabetes. Accordingly, we compared the safety and efficacy of sirolimus-eluting stents (SES) with paclitaxel-eluting stents (PES) among diabetic patients in a contemporary registry. Using the National Heart, Lung, and Blood Institute Dynamic Registry, we evaluated 2-year outcomes of diabetic patients undergoing percutaneous coronary interventions with SES (n=677) and PES (n=328). Clinical and demographic characteristics, including age, body mass index, insulin use, left ventricular function, and aspirin/clopidogrel use postprocedure, did not differ significantly between the groups except that PES-treated patients had a greater frequency of hypertension and hyperlipidemia. At the 2-year follow-up, no significant differences were observed between PES and SES with regard to safety or efficacy end points. PES- and SES-treated patients had similar rates of death (10.7% versus 8.2%, P=0.20), death and myocardial infarction (14.9% versus 13.6%, P=0.55), repeat revascularization (14.8% versus 17.8%, P=0.36), and stent thrombosis (1.3% versus 1.3%, P=0.95). After adjustment, no significant differences between the 2 stent types in any outcome were observed. PES and SES are equally efficacious and have similar safety profiles in diabetic patients undergoing percutaneous coronary interventions in clinical practice.

  13. Percutaneous transsplenic portal vein catheterization: technical procedures, safety, and clinical applications.

    PubMed

    Zhu, Kangshun; Meng, Xiaochun; Zhou, Bin; Qian, Jiesheng; Huang, Wensou; Deng, Meihai; Shan, Hong

    2013-04-01

    To evaluate the safety and feasibility of percutaneous transsplenic portal vein catheterization (PTSPC) by retrospective review of its use in patients with portal vein (PV) occlusion. From July 2004 to December 2010, 46 patients with a history of uncontrolled gastroesophageal variceal bleeding secondary to portal hypertension underwent endovascular PV interventions via a percutaneous transsplenic approach. All patients had occlusion of the main PV or central intrahepatic PV branches, which prevented the performance of a transhepatic approach. A vein within the splenic parenchyma was punctured under fluoroscopic guidance by referencing preoperative computed tomography images. PTSPC-related complications and clinical applications were analyzed. PTSPC was successfully performed in 44 of 46 patients (96%); two failures were caused by inaccessible small intrasplenic veins. PTSPC-related major bleeding complications occurred in three patients (6.5%), including large intraperitoneal hemorrhage in one patient and large splenic subcapsular hemorrhage in two patients. Two of the three patients developed hypotension, and one developed severe anemia. All three of the patients required blood transfusions. PTSPC-related minor bleeding complications occurred in six patients (13%) as a result of a small splenic subcapsular hemorrhage. In addition, three patients exhibited mild left pleural effusion, which subsided spontaneously 1 week later. All 44 patients successfully treated via PTSPC received gastroesophageal variceal embolization. Eight patients received PV stents, five for treatment of PV occlusion and three during transjugular intrahepatic portosystemic shunt placement. PTSPC is a safe and effective access for endovascular PV interventions in patients without a transhepatic window. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  14. Primary and Secondary Stroke Prevention Using Left Atrial Appendage Closure with Watchman Devices in Atrial Fibrillation Patients: A Single Center Experience from Mainland China.

    PubMed

    Chen, Yanhong; Zhang, Yonghua; Huang, Weiping; Huang, Keqiang; Xu, Bei; Su, X I

    2017-06-01

    Atrial fibrillation (AF) is associated with increased stroke risk resulting from cardiac embolism of the left atrial appendage (LAA). Stroke tends to recur in NVAF patients. Yet safety and feasibility of secondary stroke preventions with LAA closure (LAAC) have not been assessed in detail. This retrospective study was designed to compare the feasibility and safety of LAAC in primary and secondary stroke preventions, in a real-world setting of Chinese patients. From 2014 to 2015, non-valvular AF patients with CHA2DS2-VASc ≥1 were selected for percutaneous LAAC operations. Outcome observations of primary and secondary stroke preventions with Watchman devices were analyzed and compared. Overall, 122 patients were included. LAAC with Watchman devices were attempted in 115 patients, of whom 68 were for primary stroke prevention and 47 were for secondary prevention. Both the CHA2DS2-VASc score and the HASBLED score were significantly higher in the secondary prevention group (4.09 ± 1.06 vs. 1.93 ± 1.09 for CHA2DS2-VASc and 1.83 ± 1.03 vs. 1.26 ± 0.87 for HASBLED, P < 0.01). In both groups LAAC were achieved with high successful rate (98.53% in the primary prevention group and 100% in the secondary prevention group, P > 0.05) and low complication rates. The stroke rates were at a low level in both groups (1.47% in primary prevention group vs. 2.13% in secondary prevention group, P > 0.05). In our initial single-center experience, percutaneous LAA closure was a feasible and safe procedure for both primary and secondary stroke preventions in Chinese patients with nonvalvular AF. © 2017 Wiley Periodicals, Inc.

  15. Use and effectiveness of intra-aortic balloon pumps among patients undergoing high risk percutaneous coronary intervention: insights from the National Cardiovascular Data Registry.

    PubMed

    Curtis, Jeptha P; Rathore, Saif S; Wang, Yongfei; Chen, Jersey; Nallamothu, Brahmajee K; Krumholz, Harlan M

    2012-01-01

    Intra-aortic balloon pumps (IABP) frequently are used to provide hemodynamic support during high risk percutaneous coronary intervention (PCI), but clinical evidence to support their use is mixed. We examined hospital variation in IABP use among high risk PCI patients, and determined the association of IABP use on mortality in this population. We analyzed data submitted to the CathPCI Registry between January 2005 and December 2007. High risk PCI was defined as having at least 1 of the following features: unprotected left main artery as the target vessel, cardiogenic shock, severely depressed left ventricular function, or ST segment elevation myocardial infarction. Hospitals were categorized into quartiles by their proportional use of IABP. We examined differences in in-hospital mortality across hospital quartiles using a hierarchical logistic regression model to adjust for differences in patient and hospital characteristics across hospital quartiles of IABP use. IABPs were used in 18,990 (10.5%) of 181,599 high risk PCIs. Proportional use of IABP varied significantly across hospital quartiles: Q1, 0.0 to 6.5%; Q2, 6.6 to 9.2%; Q3, 9.3 to 14.1%; Q4, 14.2 to 40.0%. In multivariable analysis, after adjustment for differences in patient and hospital characteristics, in-hospital mortality was comparable across quartiles of hospital IABP usage (Q1, Ref; Q2, odds ratio 1.11, 95% CI 0.99-1.24; Q3, OR 1.03, 95% CI 0.92-1.15; Q4, OR 1.06, 95% CI 0.94-1.18). IABP use varied significantly across hospitals for high risk PCI. However, this variation in IABP use was not associated with differences in in-hospital mortality.

  16. Use and Effectiveness of Intra-Aortic Balloon Pumps Among Patients Undergoing High Risk Percutaneous Coronary Intervention: Insights from the NCDR®

    PubMed Central

    Curtis, Jeptha P.; Rathore, Saif S.; Wang, Yongfei; Chen, Jersey; Nallamothu, Brahmajee K.; Krumholz, Harlan M.

    2013-01-01

    Background IABPs are frequently used to provide hemodynamic support during high risk percutaneous coronary intervention (PCI), but clinical evidence to support their use is mixed. We examined hospital variation in IABP use among high risk PCI patients, and determined the association of IABP use on mortality in this population. Methods and Results We analyzed data submitted to the CathPCI Registry® between January 2005 and December 2007. High risk PCI was defined as having at least one of the following features: unprotected left main artery as the target vessel, cardiogenic shock, severely depressed left ventricular function, or ST segment elevation myocardial infarction. Hospitals were categorized into quartiles by their proportional use of IABP. We examined differences in in-hospital mortality across hospital quartiles using a hierarchical logistic regression model to adjust for differences in patient and hospital characteristics across hospital quartiles of IABP use. IABPs were used in 18,990 (10.5%) of 181,599 high risk PCIs. Proportional use of IABP varied significantly across hospital quartiles: Q1: 0.0%–6.5%; Q2: 6.6% to 9.2%; Q3: 9.3% to 14.1%; and Q4: 14.2% to 40.0%. In multivariable analysis, after adjustment for differences in patient and hospital characteristics, in-hospital mortality was comparable across quartiles of hospital IABP usage (Q1: Ref; Q2: Odds Ratio (OR) 1.11, 95% CI 0.99–1.24; Q3: OR 1.03, 95% CI 0.92–1.15; Q4: OR 1.06, 95% CI 0.94–1.18). Conclusion IABP use varied significantly across hospitals for high risk PCI. However, this variation in IABP use was not associated with differences in in-hospital mortality. PMID:22147887

  17. Management of third branchial pouch anomalies - an evolution of a minimally invasive technique.

    PubMed

    Wong, Phui Yee; Moore, Andrew; Daya, Hamid

    2014-03-01

    The management of third branchial pouch anomalies has evolved in recent times with the popularisation of the endoscopic diathermy technique to sclerose the pyriform fossa sinus opening. We present our experience in managing 3 children with third branchial pouch anomalies and propose a minimally invasive management algorithm avoiding open neck surgery. Retrospective case review of 3 patients including demographics, mode of presentation, investigations, management and complications. Three children, two male and one female of mean age 9.6 years presented with painful left anterior neck swelling. Axial neck imaging showed a superficial abscess with air locules and a sinus tract leading towards the left pharynx. Diagnosis was confirmed by endoscopic examination of the pyriform fossa revealing a sinus opening. Two patients underwent open excision; one combined with diathermy to the sinus opening. The last patient was diagnosed at his initial presentation and managed with endoscopic diathermy of the sinus opening combined with percutaneous needle aspiration of the neck abscess at the same sitting. One patient had two recurrences, the first after initial open surgery and the second after the first cautery. Two patients developed temporary hoarseness after the procedure, which resolved within two weeks. All patients were free from recurrences at follow-up. Introduction of the technique of endoscopic diathermy to the pyriform fossa sinus opening in children with third branchial pouch anomalies has revolutionised their management avoiding open and potentially morbid surgery. Our algorithm takes this further by advocating percutaneous needle aspiration of the infective component and performing diathermy to the sinus opening at the first presentation. Crown Copyright © 2013. Published by Elsevier Ireland Ltd. All rights reserved.

  18. Periprocedural intracardiac echocardiography for left atrial appendage closure: a dual-center experience.

    PubMed

    Berti, Sergio; Paradossi, Umberto; Meucci, Francesco; Trianni, Giuseppe; Tzikas, Apostolos; Rezzaghi, Marco; Stolkova, Miroslava; Palmieri, Cataldo; Mori, Fabio; Santoro, Gennaro

    2014-09-01

    This dual-center study sought to demonstrate the utility and safety of intracardiac echocardiography (ICE) in providing adequate imaging guidance as an alternative to transesophageal echocardiography (TEE) during Amplatzer Cardiac Plug device implantation. Over 90% of intracardiac thrombi in atrial fibrillation originate from the left atrial appendage (LAA). Patients with contraindications to anticoagulation are potential candidates for LAA percutaneous occlusion. TEE is typically used to guide implantation. ICE-guided percutaneous LAA closure was performed in 121 patients to evaluate the following tasks typically achieved by TEE: assessment of the LAA dimension for device sizing; guidance of transseptal puncture; verification of the delivery sheath position; confirmation of location and stability of the device before and after release and continuous monitoring to detect procedural complications. In 51 consecutive patients, we compared the measurements obtained by ICE and fluoroscopy to choose the size of the device. The device was successfully implanted in 117 patients, yielding a technical success rate of 96.7%. Procedural success was achieved in 113 cases (93.4%). Four major adverse events (3 cardiac tamponades and 1 in-hospital transient ischemic attack) occurred. There was significant correlation in the measurements for device sizing assessed by angiography and ICE (r = 0.94, p < 0.0001). ICE imaging was able to perform the tasks typically provided by TEE during implantation of the Amplatzer Cardiac Plug device for LAA occlusion. Therefore, we provide evidence that the use of ICE offered accurate measurements of LAA dimension in order to select the correct device sizes. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. Infarct size and left ventricular remodelling after preventive percutaneous coronary intervention

    PubMed Central

    Mangion, Kenneth; Carrick, David; Hennigan, Barry W; Payne, Alexander R; McClure, John; Mason, Maureen; Das, Rajiv; Wilson, Rebecca; Edwards, Richard J; Petrie, Mark C; McEntegart, Margaret; Eteiba, Hany; Oldroyd, Keith G; Berry, Colin

    2016-01-01

    Objective We hypothesised that, compared with culprit-only primary percutaneous coronary intervention (PCI), additional preventive PCI in selected patients with ST-elevation myocardial infarction with multivessel disease would not be associated with iatrogenic myocardial infarction, and would be associated with reductions in left ventricular (LV) volumes in the longer term. Methods In the preventive angioplasty in myocardial infarction trial (PRAMI; ISRCTN73028481), cardiac magnetic resonance (CMR) was prespecified in two centres and performed (median, IQR) 3 (1, 5) and 209 (189, 957) days after primary PCI. Results From 219 enrolled patients in two sites, 84% underwent CMR. 42 (50%) were randomised to culprit-artery-only PCI and 42 (50%) were randomised to preventive PCI. Follow-up CMR scans were available in 72 (86%) patients. There were two (4.8%) cases of procedure-related myocardial infarction in the preventive PCI group. The culprit-artery-only group had a higher proportion of anterior myocardial infarctions (MIs) (55% vs 24%). Infarct sizes (% LV mass) at baseline and follow-up were similar. At follow-up, there was no difference in LV ejection fraction (%, median (IQR), (culprit-artery-only PCI vs preventive PCI) 51.7 (42.9, 60.2) vs 54.4 (49.3, 62.8), p=0.23), LV end-diastolic volume (mL/m2, 69.3 (59.4, 79.9) vs 66.1 (54.7, 73.7), p=0.48) and LV end-systolic volume (mL/m2, 31.8 (24.4, 43.0) vs 30.7 (23.0, 36.3), p=0.20). Non-culprit angiographic lesions had low-risk Syntax scores and 47% had non-complex characteristics. Conclusions Compared with culprit-only PCI, non-infarct-artery MI in the preventive PCI strategy was uncommon and LV volumes and ejection fraction were similar. PMID:27504003

  20. Predicting device failure after percutaneous repair of functional mitral regurgitation in advanced heart failure: Implications for patient selection.

    PubMed

    Stolfo, Davide; De Luca, Antonio; Morea, Gaetano; Merlo, Marco; Vitrella, Giancarlo; Caiffa, Thomas; Barbati, Giulia; Rakar, Serena; Korcova, Renata; Perkan, Andrea; Pinamonti, Bruno; Pappalardo, Aniello; Berardini, Alessandra; Biagini, Elena; Saia, Francesco; Grigioni, Francesco; Rapezzi, Claudio; Sinagra, Gianfranco

    2018-04-15

    Patients with heart failure (HF) and severe symptomatic functional mitral regurgitation (FMR) may benefit from MitraClip implantation. With increasing numbers of patients being treated the success of procedure becomes a key issue. We sought to investigate the pre-procedural predictors of device failure in patients with advanced HF treated with MitraClip. From April 2012 to November 2016, 76 patients with poor functional class (NYHA class III-IV) and severe left ventricular (LV) remodeling underwent MitraClip implantation at University Hospitals of Trieste and Bologna (Italy). Device failure was assessed according to MVARC criteria. Patients were subsequently followed to additionally assess the patient success after 12months. Mean age was 67±12years, the mean Log-EuroSCORE was 23.4±16.5%, and the mean LV end-diastolic volume index and ejection fraction (EF) were 112±33ml/m 2 and 30.6±8.9%, respectively. At short-term evaluation, device failure was observed in 22 (29%) patients. Univariate predictors of device failure were LVEF, LV and left atrial volumes and anteroposterior mitral annulus diameter. Annulus dimension (OR 1.153, 95% CI 1.002-1.327, p=0.043) and LV end-diastolic volume (OR 1.024, 95% CI 1.000-1.049, p=0.049) were the only variables independently associated with the risk of device failure at the multivariate model. Pre-procedural anteroposterior mitral annulus diameter accurately predicted the risk of device failure after MitraClip in the setting of advanced HF. Its assessment might aid the selection of the best candidates to percutaneous correction of FMR. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Left atrial dysfunction in patients with patent foramen ovale and atrial septal aneurysm scheduled for transcatheter closure may play a role in aura genesis.

    PubMed

    Rigatelli, Gianluca; Dell'avvocata, Fabio; Cardaioli, Paolo; Ronco, Federico; Giordan, Massimo; Braggion, Gabriele; Aggio, Silvio; Chinaglia, Mauro; Cheng, Jack P; Nanjundappa, Aravinda

    2010-08-01

    It has been suggested that a left atrial (LA) dysfunction induced by large shunt and large atrial septal aneurysm (ASA) may act as a concurrent mechanism of arterial embolism in patients with patent foramen ovale (PFO) and prior stroke. We aimed to evaluate the potential contribution of this mechanism as trigger of migraine in patients with PFO. From January 2007 to September 2009, we prospectively enrolled subjects with migraine who underwent percutaneous PFO closure. Echocardiographic parameter of LA dysfunction was evaluated: pre- and postoperative values were compared to values of different sex and heart rate matched populations: 30 healthy patients, 21 migraine patients without PFO (MwoPFO), and a group of 25 PFO patients without migraine (PFOwoM). The Migraine Disability Assessment Score (MIDAS) was used to assess the incidence and severity of migraine. Forty-five patients (38 females, mean age 38 +/- 6.7 years, mean MIDAS 35.8 +/- 4.7, and 28 patients with migraine with aura) fulfilled the inclusion criteria. After successful percutaneous closure (mean follow-up of 18.2 +/- 4.8 months), PFO closure remained complete in 95%; 35 of 45 patients reported resolution or amelioration of migraine (mean MIDAS score 12.3 +/- 8.8, P < 0.03). All patients with aura reported aura resolution. Preclosure values demonstrated significantly greater LA dysfunction, when compared with healthy and MwoPFO groups. Among patients in the study group, only patients with migraine with aura showed LA dysfunction comparable to PFOwoM patients. This study suggests that LA dysfunction probably does not contribute to migraine itself but may play a role in the genesis of aura symptoms.

  2. The impact of right ventricular stroke work on B-type natriuretic peptide levels in patients with mitral stenosis undergoing percutaneous mitral valvuloplasty.

    PubMed

    Esteves, William A M; Lodi-Junqueira, Lucas; Neto, Cirilo P Fonseca; Tan, Timothy C; Nascimento, Bruno R; Mehrotra, Praveen; Barbosa, Marcia M; Ribeiro, Antonio Luiz P; Nunes, Maria Carmo P

    2013-10-01

    We aimed to explore the relationship between brain natriuretic peptide (BNP) levels and right ventricular (RV) function in patients with mitral stenosis (MS), and to investigate the hemodynamic parameters that predict reduction of BNP levels after percutaneous mitral valvuloplasty (PMV). Few studies have evaluated BNP in the context of MS, specifically the impact of the RV stroke work (RVSW) on serum BNP levels has not been defined. Thirty patients with symptomatic rheumatic MS in sinus rhythm who were referred for a PMV were enrolled. Right and left heart pressures were obtained before and after valvuloplasty. RVSW index (RVSWI) was calculated by cardiac catheterization. Basal BNP levels were elevated in MS patients and correlated with several hemodynamic parameters including pulmonary pressure, pulmonary vascular resistance index, cardiac index (CI), and RVSWI. In multivariate analysis, CI and RVSWI were independent predictors of raised basal BNP levels. PMV resulted in a significant decrease in the RVSWI with a concurrent increase in CI (2.4 ± 0.43 to 2.9 ± 0.8 L/min/m(2), P = 0.010). Overall, plasma BNP levels significantly decreased from 124 (63/234) to 73 (48/148) pg/ml postvalvuloplasty. Multivariate analysis revealed that the reduction of left atrial (LA) pressure post-PMV was an independent predictor of change in BNP levels. Elevated baseline BNP level in MS patients was independently associated with CI and RVSWI. Plasma BNP levels were reduced after successful PMV, which was associated with the reduction of the LA pressure. © 2013, Wiley Periodicals, Inc.

  3. Characterizing left-right gait balance using footstep-induced structural vibrations

    NASA Astrophysics Data System (ADS)

    Fagert, Jonathon; Mirshekari, Mostafa; Pan, Shijia; Zhang, Pei; Noh, Hae Young

    2017-04-01

    In this paper, we introduce a method for estimating human left/right walking gait balance using footstep-induced structural vibrations. Understanding human gait balance is an integral component of assessing gait, neurological and musculoskeletal conditions, overall health status, and risk of falls. Existing techniques utilize pressure- sensing mats, wearable devices, and human observation-based assessment by healthcare providers. These existing methods are collectively limited in their operation and deployment; often requiring dense sensor deployment or direct user interaction. To address these limitations, we utilize footstep-induced structural vibration responses. Based on the physical insight that the vibration energy is a function of the force exerted by a footstep, we calculate the vibration signal energy due to a footstep and use it to estimate the footstep force. By comparing the footstep forces while walking, we determine balance. This approach enables non-intrusive gait balance assessment using sparsely deployed sensors. The primary research challenge is that the floor vibration signal energy is also significantly affected by the distance between the footstep location and the vibration sensor; this function is unclear in real-world scenarios and is a mixed function of wave propagation and structure-dependent properties. We overcome this challenge through footstep localization and incorporating structural factors into an analytical force-energy-distance function. This function is estimated through a nonlinear least squares regression analysis. We evaluate the performance of our method with a real-world deployment in a campus building. Our approach estimates footstep forces with a RMSE of 61.0N (8% of participant's body weight), representing a 1.54X improvement over the baseline.

  4. Deployable video conference table

    NASA Technical Reports Server (NTRS)

    Cohen, Marc M. (Inventor); Lissol, Peter (Inventor)

    1993-01-01

    A deployable table is presented. The table is stowed in and deployed from a storage compartment based upon a non-self rigidizing, 4-hinge, arch support structure that folds upon itself to stow and that expands to deploy. The work surfaces bypass each other above and below to allow the deployment mechanism to operate. This assembly includes the following: first and second primary pivot hinges placed at the opposite ends of the storage compartment; first and second lateral frame members with proximal ends connected to the first and second pivot hinges; a medial frame member offset from and pivotally connected to distal ends of the first and second members through third and fourth medial pivot hinges; and left-side, right-side, and middle trays connected respectively to the first, second, and third frame members and being foldable into and out of the storage compartment by articulation of the first, second, third, and fourth joints. At least one of the third and fourth joints are locked to set the first, second, and third frame members in a desired angular orientation with respect to each other.

  5. Implantable physiologic controller for left ventricular assist devices with telemetry capability.

    PubMed

    Asgari, Siavash S; Bonde, Pramod

    2014-01-01

    Rotary type left ventricular assist devices have mitigated the problem of durability associated with earlier pulsatile pumps and demonstrated improved survival. However, the compromise is the loss of pulsatility due to continuous flow and retained percutaneous driveline leading to increased mortality and morbidity. Lack of pulsatility is implicated in increased gastrointestinal bleeding, aortic incompetence, and diastolic hypertension. We present a novel, wirelessly powered, ultra-compact, implantable physiologic controller capable of running a left ventricular assist device in a pulsatile mode with wireless power delivery. The schematic of our system was laid out on a circuit board to wirelessly receive power and run a left ventricular assist device with required safety and backup measures. We have embedded an antenna and wireless network for telemetry. Multiple signal processing steps and controlling algorithm were incorporated. The controller was tested in in vitro and in vivo experiments. The controller drove left ventricular assist devices continuously for 2 weeks in an in vitro setup and in vivo without any failure. Our controller is more power efficient than the current Food and Drug Administration-approved left ventricular assist device controllers. When used with electrocardiography synchronization, the controller allowed on-demand customization of operation with instantaneous flow and revolutions per minute changes, resulting in a pulsatile flow with adjustable pulse pressure. Our test results prove the system to be remarkably safe, accurate, and efficient. The unique combination of wireless powering and small footprint makes this system an ideal totally implantable physiologic left ventricular assist device system. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  6. Hypotheses, rationale, design, and methods for prognostic evaluation of cardiac biomarker elevation after percutaneous and surgical revascularization in the absence of manifest myocardial infarction. A comparative analysis of biomarkers and cardiac magnetic resonance. The MASS-V Trial.

    PubMed

    Hueb, Whady; Gersh, Bernard J; Rezende, Paulo Cury; Garzillo, Cibele Larrosa; Lima, Eduardo Gomes; Vieira, Ricardo D'Oliveira; Garcia, Rosa Maria Rahmi; Favarato, Desiderio; Segre, Carlos Alexandre W; Pereira, Alexandre Costa; Soares, Paulo Rogério; Ribeiro, Expedito; Lemos, Pedro; Perin, Marco A; Strunz, Célia Cassaro; Dallan, Luis A O; Jatene, Fabio B; Stolf, Noedir A G; Hueb, Alexandre Ciappina; Dias, Ricardo; Gaiotto, Fabio A; da Costa, Leandro Menezes Alves; Oikawa, Fernando Teiichi Costa; de Melo, Rodrigo Morel Vieira; Serrano, Carlos Vicente; de Ávila, Luiz Francisco Rodrigues; Villa, Alexandre Volney; Filho, José Rodrigues Parga; Nomura, César; Ramires, José A F; Kalil Filho, Roberto

    2012-08-16

    Although the release of cardiac biomarkers after percutaneous (PCI) or surgical revascularization (CABG) is common, its prognostic significance is not known. Questions remain about the mechanisms and degree of correlation between the release, the volume of myocardial tissue loss, and the long-term significance. Delayed-enhancement of cardiac magnetic resonance (CMR) consistently quantifies areas of irreversible myocardial injury. To investigate the quantitative relationship between irreversible injury and cardiac biomarkers, we will evaluate the extent of irreversible injury in patients undergoing PCI and CABG and relate it to postprocedural modifications in cardiac biomarkers and long-term prognosis. The study will include 150 patients with multivessel coronary artery disease (CAD) with left ventricle ejection fraction (LVEF) and a formal indication for CABG; 50 patients will undergo CABG with cardiopulmonary bypass (CPB); 50 patients with the same arterial and ventricular condition indicated for myocardial revascularization will undergo CABG without CPB; and another 50 patients with CAD and preserved ventricular function will undergo PCI using stents. All patients will undergo CMR before and after surgery or PCI. We will also evaluate the release of cardiac markers of necrosis immediately before and after each procedure. Primary outcome considered is overall death in a 5-year follow-up. Secondary outcomes are levels of CK-MB isoenzyme and I-Troponin in association with presence of myocardial fibrosis and systolic left ventricle dysfunction assessed by CMR. The MASS-V Trial aims to establish reliable values for parameters of enzyme markers of myocardial necrosis in the absence of manifest myocardial infarction after mechanical interventions. The establishments of these indices have diagnostic value and clinical prognosis and therefore require relevant and different therapeutic measures. In daily practice, the inappropriate use of these necrosis markers has led to misdiagnosis and therefore wrong treatment. The appearance of a more sensitive tool such as CMR provides an unprecedented diagnostic accuracy of myocardial damage when correlated with necrosis enzyme markers. We aim to correlate laboratory data with imaging, thereby establishing more refined data on the presence or absence of irreversible myocardial injury after the procedure, either percutaneous or surgical, and this, with or without the use of cardiopulmonary bypass.

  7. Five-year outcomes in patients with left main disease treated with either percutaneous coronary intervention or coronary artery bypass grafting in the synergy between percutaneous coronary intervention with taxus and cardiac surgery trial.

    PubMed

    Morice, Marie-Claude; Serruys, Patrick W; Kappetein, A Pieter; Feldman, Ted E; Ståhle, Elisabeth; Colombo, Antonio; Mack, Michael J; Holmes, David R; Choi, James W; Ruzyllo, Witold; Religa, Grzegorz; Huang, Jian; Roy, Kristine; Dawkins, Keith D; Mohr, Friedrich

    2014-06-10

    Current guidelines recommend coronary artery bypass graft surgery (CABG) when treating significant de novo left main coronary artery (LM) stenosis; however, percutaneous coronary intervention (PCI) has a class IIa indication for unprotected LM disease in selected patients. This analysis compares 5-year clinical outcomes in PCI- and CABG-treated LM patients in the Synergy Between PCI With Taxus and Cardiac Surgery (SYNTAX) trial, the largest trial in this group to date. The SYNTAX trial randomly assigned 1800 patients with LM or 3-vessel disease to receive either PCI (with TAXUS Express paclitaxel-eluting stents) or CABG. The unprotected LM cohort (N=705) was predefined and powered. Major adverse cardiac and cerebrovascular event rates at 5 years was 36.9% in PCI patients and 31.0% in CABG patients (hazard ratio, 1.23 [95% confidence interval, 0.95-1.59]; P=0.12). Mortality rate was 12.8% and 14.6% in PCI and CABG patients, respectively (hazard ratio, 0.88 [95% confidence interval, 0.58-1.32]; P=0.53). Stroke was significantly increased in the CABG group (PCI 1.5% versus CABG 4.3%; hazard ratio, 0.33 [95% confidence interval, 0.12-0.92]; P=0.03) and repeat revascularization in the PCI arm (26.7% versus 15.5%; hazard ratio, 1.82 [95% confidence interval, 1.28-2.57]; P<0.01). Major adverse cardiac and cerebrovascular events were similar between arms in patients with low/intermediate SYNTAX scores but significantly increased in PCI patients with high scores (≥33). At 5 years, no difference in overall major adverse cardiac and cerebrovascular events was found between treatment groups. PCI-treated patients had a lower stroke but a higher revascularization rate versus CABG. These results suggest that both treatments are valid options for LM patients. The extent of disease should accounted for when choosing between surgery and PCI, because patients with high SYNTAX scores seem to benefit more from surgery compared with those in the lower tertiles. http://www.clinicaltrials.gov. Unique identifier: NCT00114972. © 2014 American Heart Association, Inc.

  8. Mechanical CPR: Who? When? How?

    PubMed

    Poole, Kurtis; Couper, Keith; Smyth, Michael A; Yeung, Joyce; Perkins, Gavin D

    2018-05-29

    In cardiac arrest, high quality cardiopulmonary resuscitation (CPR) is a key determinant of patient survival. However, delivery of effective chest compressions is often inconsistent, subject to fatigue and practically challenging.Mechanical CPR devices provide an automated way to deliver high-quality CPR. However, large randomised controlled trials of the routine use of mechanical devices in the out-of-hospital setting have found no evidence of improved patient outcome in patients treated with mechanical CPR, compared with manual CPR. The limited data on use during in-hospital cardiac arrest provides preliminary data supporting use of mechanical devices, but this needs to be robustly tested in randomised controlled trials.In situations where high-quality manual chest compressions cannot be safely delivered, the use of a mechanical device may be a reasonable clinical approach. Examples of such situations include ambulance transportation, primary percutaneous coronary intervention, as a bridge to extracorporeal CPR and to facilitate uncontrolled organ donation after circulatory death.The precise time point during a cardiac arrest at which to deploy a mechanical device is uncertain, particularly in patients presenting in a shockable rhythm. The deployment process requires interruptions in chest compression, which may be harmful if the pause is prolonged. It is recommended that use of mechanical devices should occur only in systems where quality assurance mechanisms are in place to monitor and manage pauses associated with deployment.In summary, mechanical CPR devices may provide a useful adjunct to standard treatment in specific situations, but current evidence does not support their routine use.

  9. Association of admission testosterone level with ST-segment resolution in male patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention.

    PubMed

    Separham, Ahmad; Ghaffari, Samad; Sohrabi, Bahram; Aslanabadi, Naser; Hadavi Bavil, Mozhgan; Lotfollahi, Hasanali

    2017-01-01

    Low level of testosterone may be associated with cardiovascular diseases in men, as some evidence suggests a protective role for testosterone in cardiovascular system. Little is known about the possible role of serum testosterone in response to reperfusion therapy in ST-elevation myocardial infarction (STEMI) and its relationship with ST-segment recovery. The present study was conducted to evaluate the association of serum testosterone levels with ST-segment resolution following primary percutaneous coronary intervention (PPCI) in male patients with acute STEMI. Forty-eight men (mean age 54.55 ± 12.20) with STEMI undergoing PPCI were enrolled prospectively. Single-lead ST segment resolution in the lead with maximum baseline ST-elevation was measured and patients were divided into two groups according to the degree of ST-segment resolution: complete (> or =50%) or incomplete (<50%). The basic and demographic data of all patients, their left ventricular ejection fraction (LVEF) and laboratory findings including serum levels of free testosterone and cardiac enzymes were recorded along with angiographic finding and baseline TIMI (Thrombolysis in Myocardial Infarction) flow and also in-hospital complications and then these variables were compared between two groups. A complete ST-resolution (≥50%) was observed in 72.9% of the patients. The serum levels of free testosterone ( P  = 0.04), peak cardiac troponin ( P  = 0.03) were significantly higher and hs-CRP ( P  = 0.02) were lower in patients with complete ST-resolution compared to those with incomplete ST-resolution. In-hospital complications were observed in 31.2% of patients. The patients with a lower baseline TIMI flow ( P  = 0.03) and those who developed complications ( P  = 0.04) had lower levels of free testosterone. A significant positive correlation was observed between the left ventricular function and serum levels of free testosterone ( P  = 0.01 and r = +0.362). This study suggests that in men with STEMI undergoing PPCI, higher serum levels of testosterone are associated with a better reperfusion response, fewer complications and a better left ventricular function.

  10. A Simple Numerical Body Surface Mapping Parameter Signifies Successful Percutaneous Coronary Artery Intervention.

    PubMed

    Simonyi, Gábor; Kirschner, Róbert; Szűcs, Endre; Préda, István; Duray, Gábor; Medvegy, Nóra; Horvath, Bálint; Medvegy, Mihály

    2016-03-01

    In coronary artery disease (CAD), body surface potential mapping (BSPM) may reveal minor electrical potential changes appearing in the depolarization phase even if pathological changes are absent on the conventional 12-lead ECG. We hypothesized that a simple BSPM parameter, Max/Min signifies successful percutaneous coronary intervention (PCI). Ninety-two adult Caucasian patients with stable CAD and positive exercise test underwent coronary angiography. Seventy patients (age, 59 ± 8; 46 males) were revascularized by PCI (left anterior descending [LAD] in 38, right [RCA] in 17 and left circumflex [LCX] coronary artery in 15). Control groups contained 22 patients (age, 60 ± 8; 14 males) without intervention and 35 healthy subjects (age, 58 ± 2; 15 males). Left ventricular ejection fraction (LVEF, transthoracic echocardiography) and Max/Min BSPM parameter (63-lead Montreal system) were evaluated before and 4-40 days following coronary angiography. Max/Min was defined by the ratio of the highest maximum to the deepest minimum potential of all leads recorded by BSPM. Before PCI, Max/Min value of patients with LAD lesion (0.83 [0.74; 0.93]) was significantly lower while that with RCA lesion (1.63 [1.35; 1.99]) was significantly higher than that of healthy group (1.01 [0.970; 1.13]) (P < 0.05) and LVEF was significantly lower in LAD lesion (46.50% [43.00; 51.00]) than in the healthy group (55.00% [50.00; 58.75]) (P < 0.01). Max/Min value significantly increased from 0.83 [0.74; 0.93] to 0.92 [0.82; 0.99] (P < 0.01) following LAD PCI while significantly decreased from 1.63 [1.35; 1.98] to 1.35 [1.21; 1.43] (P < 0.01) post-RCA PCI. It did not vary significantly, however, either following LCX PCI or without intervention. LVEF significantly increased (from 46.50% [43.00; 51.00] to 49.00% [46.00; 51.00]) only after LAD PCI. Max/Min parameter is suitable to follow patients after LAD and RCA PCI. © 2015 Wiley Periodicals, Inc.

  11. Significance of off-pump coronary artery bypass grafting compared with percutaneous coronary intervention: a propensity score analysis

    PubMed Central

    Marui, Akira; Kimura, Takeshi; Tanaka, Shiro; Furukawa, Yutaka; Kita, Toru; Sakata, Ryuzo

    2012-01-01

    OBJECTIVE Although there have been several studies that compared the efficacy of percutaneous coronary intervention (PCI) and coronary artery bypass grafting (CABG), the impact of off-pump CABG (OPCAB) has not been well elucidated. The objective of the present study was to compare the outcomes after PCI, on-pump CABG (ONCAB), and OPCAB in patients with multivessel and/or left main disease. METHODS Among the 9877 patients undergoing first PCI using bare-metal stents or CABG who were enrolled in the CREDO-Kyoto Registry, 6327 patients with multivessel and/or left main disease were enrolled into the present study (67.9 ± 9.8 years old). Among them, 3877 patients received PCI, 1388 ONCAB, and 1069 OPCAB. Median follow-up was 3.5 years. RESULTS Comparing PCI with all CABG (ONCAB and OPCAB), propensity-score-adjusted all-cause mortality after PCI was higher than that CABG (hazard ratio (95% confidence interval): 1.37 (1.15–1.63), p < 0.01). The incidence of stroke was lower after PCI than that after CABG (0.75 (0.59–0.96), p = 0.02). CABG was associated with better survival outcomes than PCI in the elderly (interaction p = 0.04). Comparing OPCAB with PCI or ONCAB, propensity-score-adjusted all-cause mortality after PCI was higher than that after OPCAB (1.50 (1.20–1.86), p < 0.01). Adjusted mortality was similar between ONCAB and OPCAB (1.18 (0.93–1.51), p = 0.33). The incidence of stroke after OPCAB was similar to that after PCI (0.98 (0.71–1.34), p > 0.99), but incidence of stroke after ONCAB was higher than that after OPCAB (1.59 (1.16–2.18), p < 0.01). CONCLUSIONS In patients with multivessel and/or left main disease, CABG, particularly OPCAB, is associated with better survival outcomes than PCI using bare-metal stents. Survival outcomes are similar between ONCAB and OPCAB. PMID:21676626

  12. Evidence of anti-inflammatory effect and percutaneous penetration of a topically applied fish oil preparation: a photoacoustic spectroscopy study

    NASA Astrophysics Data System (ADS)

    Ames, Franciele Q.; Sato, Francielle; de Castro, Lidiane V.; de Arruda, Laura L. M.; da Rocha, Bruno A.; Cuman, Roberto K. N.; Baesso, Mauro L.; Bersani-Amado, Ciomar A.

    2017-05-01

    This paper investigates the topical anti-inflammatory effect of a fish oil preparation (FOP) in a croton oil (CO) model of skin inflammation. The photoacoustic spectroscopy (PAS) was applied to estimate the percutaneous penetration of the FOP and as a model to evaluate the topical inflammatory response. After applying CO, the groups of mice received a topical application of a FOP on the left ear. The right ear received the vehicle that was used to dilute the CO. After 6 h, ear tissue was collected to determine the percent inhibition of edema, myeloperoxidase (MPO) activity, and cytokine levels and to perform PAS measurements. Treatment with FOP reduced edema and MPO activity, which was at least partially attributed to a decrease in the levels of tumor necrosis factor, interleukin-1β, interleukin-6, keratinocyte-derived chemokine, and monocyte chemoattractant protein-1. The topically applied FOP penetrated into the tissue and decreased the area of the bands that characterize inflamed tissue. The present results demonstrated the topical anti-inflammatory effect of the FOP. PAS suggests that FOP anti-inflammatory activity is linked with its ability to penetrate through the skin.

  13. 2015 SCAI/ACC/HFSA/STS Clinical Expert Consensus Statement on the Use of Percutaneous Mechanical Circulatory Support Devices in Cardiovascular Care (Endorsed by the American Heart Association, the Cardiological Society of India, and Sociedad Latino Americana de Cardiologia Intervencion; Affirmation of Value by the Canadian Association of Interventional Cardiology-Association Canadienne de Cardiologie d'intervention).

    PubMed

    Rihal, Charanjit S; Naidu, Srihari S; Givertz, Michael M; Szeto, Wilson Y; Burke, James A; Kapur, Navin K; Kern, Morton; Garratt, Kirk N; Goldstein, James A; Dimas, Vivian; Tu, Thomas

    2015-06-01

    Although historically the intra-aortic balloon pump has been the only mechanical circulatory support device available to clinicians, a number of new devices have become commercially available and have entered clinical practice. These include axial flow pumps, such as Impella(®); left atrial to femoral artery bypass pumps, specifically the TandemHeart; and new devices for institution of extracorporeal membrane oxygenation. These devices differ significantly in their hemodynamic effects, insertion, monitoring, and clinical applicability. This document reviews the physiologic impact on the circulation of these devices and their use in specific clinical situations. These situations include patients undergoing high-risk percutaneous coronary intervention, those presenting with cardiogenic shock, and acute decompensated heart failure. Specialized uses for right-sided support and in pediatric populations are discussed and the clinical utility of mechanical circulatory support devices is reviewed, as are the American College of Cardiology/American Heart Association clinical practice guidelines. Copyright © 2015. Published by Elsevier Inc.

  14. Transvaginal Drainage of Pelvic Abscesses and Collections Using Transabdominal Ultrasound Guidance.

    PubMed

    Ching, Kevin C; Sumkin, Jules H

    2015-01-01

    Objectives. To evaluate clinical outcomes following transvaginal catheter placement using transabdominal ultrasound guidance for management of pelvic fluid collections. Methods. A retrospective review was performed for all patients who underwent transvaginal catheter drainage of pelvic fluid collections utilizing transabdominal ultrasound guidance between July 2008 and July 2013. 24 consecutive patients were identified and 24 catheters were placed. Results. The mean age of patients was 48.1 years (range = 27-76 y). 88% of collections were postoperative (n = 21), 8% were from pelvic inflammatory disease (n = 2), and 4% were idiopathic (n = 1). Of the 24 patients, 83% of patients (n = 20) had previously undergone a hysterectomy and 1 patient (4%) was pregnant at the time of drainage. The mean volume of initial drainage was 108 mL (range = 5 to 570). Catheters were left in place for an average of 4.3 days (range = 1-17 d). Microbial sampling was performed in all patients with 71% (n = 17) returning a positive culture. All collections were successfully managed percutaneously. There were no technical complications. Conclusions. Transvaginal catheter drainage of pelvic fluid collections using transabdominal ultrasound guidance is a safe and clinically effective procedure. Appropriate percutaneous management can avoid the need for surgery.

  15. A Rare Complication following Thyroid Percutaneous Ethanol Injection: Plummer Adenoma

    PubMed Central

    Cesareo, Roberto; Naciu, Anda Mihaela; Pasqualini, Valerio; Pelle, Giuseppe; Manfrini, Silvia; Tabacco, Gaia; Lauria Pantano, Angelo; Casini, Alessandro; Cianni, Roberto

    2017-01-01

    Percutaneous ethanol injection (PEI) is a technique used only for benign thyroid nodules, cystic or mixed cystic-solid with a large fluid component. It is a quite low-cost, safe, and outpatient method of treatment. Rare and severe complications have been described after PEI: jugular vein thrombosis and severe ethanol toxic necrosis of the larynx combined with necrotic dermatitis. Moreover, only four thyrotoxicosis cases due to Graves' disease have been reported. We report a case of 58-year-old female with a voluminous thyroid cystic nodule, occupying almost the entire left thyroid lobe. Our patient had already performed surgical visit and intervention of thyroidectomy had been proposed to her, which she refused. At baseline, our patient has a normal thyroid function with negative autoantibodies. According to the nodular structure, intervention of PEI has been performed with a significant improvement of compressive symptoms and cosmetic disorders. About 30 days after treatment, there was a significant volume reduction, but patient developed an acclaimed symptomatic thyrotoxicosis. After ruling out several causes of hyperthyroidism and according to the thyroid scintigraphy findings, we made the diagnosis of Plummer adenoma. To our knowledge, our patient is the first case of Plummer adenoma following PEI treatment of nontoxic thyroid nodule. PMID:28465846

  16. Space Shuttle Projects

    NASA Image and Video Library

    1992-08-01

    Five NASA astronauts and one Canadian payload specialist composed the STS-52 crew. Pictured on the back row, left to right, are Michael A. Baker, pilot; James B. Wetherbee, commander; and Steven G. Maclean, payload specialist. On the front row, left to right, are mission specialists Charles (Lacy) Veach, Tamara Jernigan, and William Shepherd. Launched aboard the Space Shuttle Columbia on October 22, 1992 at 1:09:39 p.m. (EDT), the crew’s primary objectives were the deployment of the Laser Geodynamic Satellite (LAGEOS II) and operation of the U.S. Microgravity Payload-1 (USMP-1).

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Close, Orrie N.; Akinwande, Olaguoke; Varma, Rakesh K.

    Postoperative biliary complications following extensive hepatic resections are complex, often requiring a multidisciplinary team approach. We describe a case of a free bile duct leak following extended right hepatectomy and surgical hepaticojejunostomy treated with percutaneous transhepatic hepaticojejunostomy in which a radiofrequency guidewire was used to gain enteral access. A modified internal/external biliary catheter was left in place. The patient was enrolled in a benign biliary stricture protocol, and 8 months later, the catheter was removed following a normal cholangiogram and biliary manometric perfusion testing. At 3-month follow-up after catheter removal, the patient is asymptomatic with no clinical, biochemical, or radiographic evidencemore » of biliary leak or obstruction.« less

  18. [Anesthetic management of a patient with HOCM even after PTSMA].

    PubMed

    Fujimoto, Hiroko; Kamiya, Yoshinori; Ohki, Hiroshi; Goto, Takahisa

    2008-10-01

    A 74-year-old woman previously treated with percutaneous transluminnal septal myocardial ablation (PTSMA) for severe hypertrophic obstructive cardiomyopathy (HOCM) underwent laparoscopic cholecystectomy under general anesthesia. The PTSMA was performed for HOCM 5 month before surgery and the left ventricular outflow pressure gradient (LVOTG) was reduced from 100 mmHg to 30 mmHg. After anesthetic induction, severe hypotension occurred concomitantly with asymmetrical septal hypertrophy (ASH) and systolic anterior movement of the mitral valve leaflet (SAM). Hypotension was treated with fluid therapy and the vasopressors (methoxamine and noradrenaline). Care should be taken for the anesthetic management of a patient with HOCM even after PTSMA.

  19. Pressure ulcer: an unreported complication of the Safeguard® hemostasis device. No need to crack under pressure

    PubMed Central

    Moretti, Claudio; Quadri, Giorgio; Gaita, Fiorenzo; Sheiban, Imad

    2011-01-01

    Diagnostic cardiac catheterizations are predominantly performed using the femoral artery access. Several devices have been developed to aid in the closure of femoral arteriotomy. Safeguard® is a new pneumatic compression device that has been developed for compression of the femoral artery after brief manual compression. We hereby report the case of an elderly patient who underwent a percutaneous coronary intervention via the femoral artery in whom a Safeguard™ device, left overnight because of persistent oozing, provoked an extensive pressure ulcer. Knowledge of this potential complication is important to minimize its occurance and provide appropriate treatment. PMID:21977303

  20. Pressure ulcer: an unreported complication of the Safeguard® hemostasis device. No need to crack under pressure.

    PubMed

    Moretti, Claudio; Quadri, Giorgio; Gaita, Fiorenzo; Sheiban, Imad

    2011-01-01

    Diagnostic cardiac catheterizations are predominantly performed using the femoral artery access. Several devices have been developed to aid in the closure of femoral arteriotomy.Safeguard® is a new pneumatic compression device that has been developed for compression of the femoral artery after brief manual compression. We hereby report the case of an elderly patient who underwent a percutaneous coronary intervention via the femoral artery in whom a Safeguard™ device, left overnight because of persistent oozing, provoked an extensive pressure ulcer. Knowledge of this potential complication is important to minimize its occurance and provide appropriate treatment.

  1. Percutaneous needle placement using laser guidance: a practical solution

    NASA Astrophysics Data System (ADS)

    Xu, Sheng; Kapoor, Ankur; Abi-Jaoudeh, Nadine; Imbesi, Kimberly; Hong, Cheng William; Mazilu, Dumitru; Sharma, Karun; Venkatesan, Aradhana M.; Levy, Elliot; Wood, Bradford J.

    2013-03-01

    In interventional radiology, various navigation technologies have emerged aiming to improve the accuracy of device deployment and potentially the clinical outcomes of minimally invasive procedures. While these technologies' performance has been explored extensively, their impact on daily clinical practice remains undetermined due to the additional cost and complexity, modification of standard devices (e.g. electromagnetic tracking), and different levels of experience among physicians. Taking these factors into consideration, a robotic laser guidance system for percutaneous needle placement is developed. The laser guidance system projects a laser guide line onto the skin entry point of the patient, helping the physician to align the needle with the planned path of the preoperative CT scan. To minimize changes to the standard workflow, the robot is integrated with the CT scanner via optical tracking. As a result, no registration between the robot and CT is needed. The robot can compensate for the motion of the equipment and keep the laser guide line aligned with the biopsy path in real-time. Phantom experiments showed that the guidance system can benefit physicians at different skill levels, while clinical studies showed improved accuracy over conventional freehand needle insertion. The technology is safe, easy to use, and does not involve additional disposable costs. It is our expectation that this technology can be accepted by interventional radiologists for CT guided needle placement procedures.

  2. Impending rupture of saphenous vein graft aneurysm with floating fractured bare metal stent treated by coil embolization and covered stent implantation.

    PubMed

    Kodama, Atsuko; Kurita, Tairo; Kato, Osamu; Suzuki, Takahiko

    2016-11-01

    Aneurysmal degeneration of a saphenous vein graft (SVG) is a rare, but potentially fatal complication of coronary artery bypass graft (CABG) surgery. In this case report, a patient that had undergone prior CABG surgery and bare metal stent (BMS) implantation at the site of a stenotic SVG lesion presented at our hospital with chest pain, and an SVG aneurysm was detected at the previous BMS implantation site. In addition, the implanted BMS was fractured and floating in the SVG aneurysm. The SVG aneurysm was successfully occluded by percutaneous intervention, using a combination of distal covered stent deployment at the site of the anastomosis between the native coronary artery and the SVG and proximal coil embolization of the aneurysm.

  3. NOBLE and EXCEL: The debate for excellence in dealing with left main stenosis.

    PubMed

    Kindi, Hamood Al; Samaan, Amir; Hosny, Hatem

    2018-03-14

    Left main coronary artery (LMCA) disease is associated with increased morbidity and mortality. Coronary artery bypass grafting surgery (CABG) has always been the standard revascularization strategy for this group of patients. However, with the recent developments in stents design and medical therapy over the past decade, several trials have been designed to evaluate the safety and efficacy of percutaneous coronary intervention (PCI) as an alternative to CABG surgery in patients with LMCA disease. Recently, the results of two major trials, EXCEL and NOBLE, comparing CABG versus PCI in this patient population have been released. In fact, the results of both trials might appear contradictory at first glance. While the EXCEL trial showed that PCI was non-inferior to CABG surgery, the NOBLE trial suggested that CABG surgery is a better option. In the following review, we will discuss some of the similarities and contrasts between these two trials and conclude with lessons to be learned to our daily practice.

  4. NOBLE and EXCEL: The debate for excellence in dealing with left main stenosis

    PubMed Central

    Kindi, Hamood Al; Samaan, Amir

    Left main coronary artery (LMCA) disease is associated with increased morbidity and mortality. Coronary artery bypass grafting surgery (CABG) has always been the standard revascularization strategy for this group of patients. However, with the recent developments in stents design and medical therapy over the past decade, several trials have been designed to evaluate the safety and efficacy of percutaneous coronary intervention (PCI) as an alternative to CABG surgery in patients with LMCA disease. Recently, the results of two major trials, EXCEL and NOBLE, comparing CABG versus PCI in this patient population have been released. In fact, the results of both trials might appear contradictory at first glance. While the EXCEL trial showed that PCI was non-inferior to CABG surgery, the NOBLE trial suggested that CABG surgery is a better option. In the following review, we will discuss some of the similarities and contrasts between these two trials and conclude with lessons to be learned to our daily practice. PMID:29644230

  5. Association of a patent foramen ovale with myocardial infarction and pulmonary emboli in a peripartum woman.

    PubMed

    Ramineni, Rajesh; Daniel, George K

    2010-10-01

    Peripartum myocardial infarction is uncommon but devastating in young women. Although it is generally associated with arterial dissection, pregnancy-induced hypercoagulable state can also be a major contributor. Association of patent foramen ovale (PFO) adds to this potential risk. A 29-year-old postpartum female presented with worsening chest pressure, shortness of breath and syncope. She was hypotensive and tachycardic. A ventilation perfusion imaging displayed high probability for pulmonary emboli. With elevated cardiac enzymes and echocardiogram showing wall motion abnormalities, patient underwent percutaneous coronary angioplasty for a midvessel thrombus in the left anterior descending artery. Further workup showed a thrombus straddling into the left atrium via a PFO and a deep venous thrombus in the right iliac vein. Hormonal changes in pregnancy are noted to place young women in a hypercoagulable state. Screening for PFO in this group of patients with timely intervention might prevent a major systemic event caused by paradoxical embolus.

  6. Percutaneous biliary drainage for high obstruction.

    PubMed

    Barth, K H

    1990-11-01

    PBD is the preferred route of palliative drainage for patients with high biliary obstruction. The frequency of bifurcational obstruction in this setting requires familiarity with drainages from both the right and the left transhepatic approach. The preferred right transhepatic approach is fluoroscopically guided; on the left, ultrasonography is the guidance of choice. Large caliber drainage catheters are required, and dilatation of the necessary transhepatic tracts is extremely painful unless adequate inhalation anesthesia or, preferably, epidural anesthesia, is provided. Long-term biliary drainage requires a choice between internal-external external drainage catheters and endoprostheses that is made by considering the patient's life expectancy and his or her adjustment to a stent extending to the outside. The feasibility of corrective procedures if an internal-external drainage catheter or an endoprosthesis becomes blocked needs to be considered before definitive placement. The interventional radiologist becomes intimately involved in the follow-up care of patients and frequently has to direct appropriate patient evaluation. Familiarity with antibiotic regimens is important.

  7. Percutaneous left atrial appendage occlusion: the Munich consensus document on definitions, endpoints, and data collection requirements for clinical studies.

    PubMed

    Tzikas, Apostolos; Holmes, David R; Gafoor, Sameer; Ruiz, Carlos E; Blomström-Lundqvist, Carina; Diener, Hans-Christoph; Cappato, Riccardo; Kar, Saibal; Lee, Randal J; Byrne, Robert A; Ibrahim, Reda; Lakkireddy, Dhanunjaya; Soliman, Osama I; Nabauer, Michael; Schneider, Steffen; Brachmann, Johannes; Saver, Jeffrey L; Tiemann, Klaus; Sievert, Horst; Camm, A John; Lewalter, Thorsten

    2017-01-01

    The increasing interest in left atrial appendage occlusion (LAAO) for ischaemic stroke prevention in atrial fibrillation (AF) fuels the need for more clinical data on the safety and effectiveness of this therapy. Besides an assessment of the effectiveness of the therapy in specific patients groups, comparisons with pharmacological stroke prophylaxis, surgical approaches, and other device-based therapies are warranted. This paper documents the consensus reached among clinical experts in relevant disciplines from Europe and North America, European cardiology professional societies, and representatives from the medical device industry regarding definitions for parameters and endpoints to be assessed in clinical studies. Adherence to these definitions is proposed in order to achieve a consistent approach across clinical studies on LAAO among the involved stakeholders and various clinical disciplines and thereby facilitate continued evaluation of therapeutic strategies available. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  8. Transvenous Embolization of a Spontaneous Femoral AVF 5 Years After an Incomplete Treatment with Arterial Stent-Grafts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peynircioglu, Bora; Ozkan, Murat; Dogan, Omer Faruk

    2008-03-15

    A 66-year-old man with complex left femoral arterio-venous fistula (AVF) was first diagnosed after a deep venous thrombosis incident approximately 5 years ago. Partial treatment was performed by means of endografts along the superficial femoral artery, which remained patent for 5 years. The patient had been doing well until a couple of months ago when he developed severe venous stasis and ulcers of the left cruris, due to a high-flow nonhealing complex AVF with additional iliac vein occlusion. Therefore; the definitive treatment was performed by a unique endovascular technique combined with surgical venous bypass (femoro-femoral crossover saphenous bypass, the Palmamore » operation). A novel percutaneous transvenous technique for occlusion of a complex high-flow AVF is reported with a review of the literature. The case is unique with spontaneous AVF, transvenous embolization with detachable coils and ONYX, and the hybrid treatment technique as well as the long-term patency of superficial femoral artery stent-grafts.« less

  9. Endogenous Klebsiella endophthalmitis associated with liver abscess: first case report from iran.

    PubMed

    Dehghani, A R; Masjedi, A; Fazel, F; Ghanbari, H; Akhlaghi, M; Karbasi, N

    2011-01-07

    To report the first case of endogenous Klebsiella endophthalmitis associated with liver abscess in Iran. A 79-year-old man was referred to our hospital due to severe pain and visual loss in the left eye. On physical examination, conjunctival hyperemia, corneal edema, hypopyon and severe vitreous cellular reaction were identified in the left eye; however, yellowish conjunctival discoloration was more apparent in the right eye. Abdominal CT scan showed a right liver lobe abscess that was confirmed by sonographically guided percutaneous liver mass biopsy. Blood, vitreous and liver mass aspirate cultures revealed Klebsiella pneumoniae growth. The patient was thus diagnosed with endogenous Klebsiella endophthalmitis secondary to bacteremia associated with liver abscess. This report suggests that, rather than being confined to Taiwan, endogenous endophthalmitis secondary to a liver abscess due to K. pneumoniae may be a global problem. Therefore, physicians should be aware of the possibility of endophthalmitis whenever a patient with K. pneumoniae liver abscess complains of ocular symptoms.

  10. Everolimus-Eluting Stents or Bypass Surgery for Left Main Coronary Artery Disease.

    PubMed

    Stone, Gregg W; Sabik, Joseph F; Serruys, Patrick W; Simonton, Charles A; Généreux, Philippe; Puskas, John; Kandzari, David E; Morice, Marie-Claude; Lembo, Nicholas; Brown, W Morris; Taggart, David P; Banning, Adrian; Merkely, Béla; Horkay, Ferenc; Boonstra, Piet W; van Boven, Ad J; Ungi, Imre; Bogáts, Gabor; Mansour, Samer; Noiseux, Nicolas; Sabaté, Manel; Pomar, José; Hickey, Mark; Gershlick, Anthony; Buszman, Pawel; Bochenek, Andrzej; Schampaert, Erick; Pagé, Pierre; Dressler, Ovidiu; Kosmidou, Ioanna; Mehran, Roxana; Pocock, Stuart J; Kappetein, A Pieter

    2016-12-08

    Patients with obstructive left main coronary artery disease are usually treated with coronary-artery bypass grafting (CABG). Randomized trials have suggested that drug-eluting stents may be an acceptable alternative to CABG in selected patients with left main coronary disease. We randomly assigned 1905 eligible patients with left main coronary artery disease of low or intermediate anatomical complexity to undergo either percutaneous coronary intervention (PCI) with fluoropolymer-based cobalt-chromium everolimus-eluting stents (PCI group, 948 patients) or CABG (CABG group, 957 patients). Anatomic complexity was assessed at the sites and defined by a Synergy between Percutaneous Coronary Intervention with Taxus and Cardiac Surgery (SYNTAX) score of 32 or lower (the SYNTAX score reflects a comprehensive angiographic assessment of the coronary vasculature, with 0 as the lowest score and higher scores [no upper limit] indicating more complex coronary anatomy). The primary end point was the rate of a composite of death from any cause, stroke, or myocardial infarction at 3 years, and the trial was powered for noninferiority testing of the primary end point (noninferiority margin, 4.2 percentage points). Major secondary end points included the rate of a composite of death from any cause, stroke, or myocardial infarction at 30 days and the rate of a composite of death, stroke, myocardial infarction, or ischemia-driven revascularization at 3 years. Event rates were based on Kaplan-Meier estimates in time-to-first-event analyses. At 3 years, a primary end-point event had occurred in 15.4% of the patients in the PCI group and in 14.7% of the patients in the CABG group (difference, 0.7 percentage points; upper 97.5% confidence limit, 4.0 percentage points; P=0.02 for noninferiority; hazard ratio, 1.00; 95% confidence interval, 0.79 to 1.26; P=0.98 for superiority). The secondary end-point event of death, stroke, or myocardial infarction at 30 days occurred in 4.9% of the patients in the PCI group and in 7.9% in the CABG group (P<0.001 for noninferiority, P=0.008 for superiority). The secondary end-point event of death, stroke, myocardial infarction, or ischemia-driven revascularization at 3 years occurred in 23.1% of the patients in the PCI group and in 19.1% in the CABG group (P=0.01 for noninferiority, P=0.10 for superiority). In patients with left main coronary artery disease and low or intermediate SYNTAX scores by site assessment, PCI with everolimus-eluting stents was noninferior to CABG with respect to the rate of the composite end point of death, stroke, or myocardial infarction at 3 years. (Funded by Abbott Vascular; EXCEL ClinicalTrials.gov number, NCT01205776 .).

  11. ARC-2001-ACD01-0018

    NASA Image and Video Library

    2001-02-16

    New Center Network Deployment ribbon Cutting: from left to right: Maryland Edwards, Code JT upgrade project deputy task manager; Ed Murphy, foundry networks systems engineer; Bohdan Cmaylo, Code JT upgrade project task manager, Scott Santiago, Division Chief, Code JT; Greg Miller, Raytheon Network engineer and Frank Daras, Raytheon network engineering manager.

  12. Contractors Supporting Military Operations

    DTIC Science & Technology

    2006-04-30

    Chennault was left with “disciplinary” measures such as limiting the number of drinks a rowdy pilot was allowed at the Kunming hostel’s bar. To be...such company had been organized by 7 December 1941. It formed the nucleus of the first Construction Detachment which deployed to Bora Bora at the

  13. [Percutaneous renal puncture guide by a novel real-time needle-tracking ultrasound system for percutaneous nephrolithotomy: analysis of 16 cases].

    PubMed

    Ma, Kai; Huang, Xiao-bo; Xiong, Liu-lin; Xu, Qing-quan; Xu, Tao; Ye, Hai-yun; Yu, Lu-ping; Wang, Xiao-feng

    2014-08-18

    To evaluate the feasibility and efficacy of percutaneous renal puncture in percutaneous nephrolithotomy guided by novel needle-tracking ultrasound system. From may to october 2013, 16 cases of percutaneous nephrolithotomy were performed under the guidance of ultrasound system. The clinical data including the time of completing percutaneous renal puncture, the color of urine sucked out from the kidney calices, and the complications were analyzed retrospectively. Of the 16 patients, 18 percutaneous renal access were established guided by ultrasound system. All of them were successtul for the first time, and the average time of completing percutaneous renal punctures was (26.90 ± 11.37) s (15 to 54 s). After the operation, the hemoglobin decreased by (9.56 ± 5.27)%(1.41% to 24.06%), and no complications occurred except for postoperative fever in 2 case. The novel ultrasound system is a safe and effective technique that can reduce the technical difficulty of percutaneous renal puncture in percutaneous nephrolithotomy.

  14. Endovascular Removal of Fractured Inferior Vena Cava Filter Fragments: 5-Year Registry Data with Prospective Outcomes on Retained Fragments.

    PubMed

    Kesselman, Andrew J; Hoang, Nam Sao; Sheu, Alexander Y; Kuo, William T

    2018-06-01

    To evaluate the safety and efficacy of attempted percutaneous filter fragment removal during retrieval of fractured inferior vena cava (IVC) filters and to report outcomes associated with retained filter fragments. Over a 5-year period, 82 consecutive patients presenting with a fractured IVC filter were prospectively enrolled into an institutional review board-approved registry. There were 27 men and 55 women (mean, 47 y; range, 19-85 y). After main filter removal, percutaneous removal of fragments was attempted if they were deemed intravascular and accessible on preprocedural computed tomography (CT), cone-beam CT, and/or intravascular ultrasound; distal pulmonary artery (PA) fragments were left alone. A total of 185 fragments were identified (81 IVC, 33 PA, 16 cardiac, 2 hepatic vein, 1 renal vein, 1 aorta, 51 retroperitoneal). Mean filter dwell time was 2,183 days (range, 59-9,936 d). Eighty-seven of 185 fragments (47%) were deemed amenable to attempted removal: 65 IVC, 11 PA, 8 cardiac, 2 hepatic, and 1 aortic. Primary safety outcomes were major procedure-related complications. Fragment removal was successful in 78 of 87 cases (89.7%; 95% confidence interval [CI], 81.3-95.2). There were 6 minor complications with no consequence (6.9%; 95% CI, 2.6-14.4) involving intraprocedural fragment embolization and 1 major complication (1.1%; 95% CI, 0.0-6.2), a cardiac tamponade that was successfully treated. The complication rate from attempted cardiac fragment removal was 12.5% (1 of 8; 95% CI, 0.3-52.7). Among patients with retained cardiopulmonary fragments (n = 19), 81% remained asymptomatic during long-term clinical follow-up of 845 days (range, 386-2,071 d). Percutaneous removal of filter fragments from the IVC and proximal PAs is safe and effective overall, but attempted intracardiac fragment removal carries a higher risk of complication. Most residual filter fragments not amenable to percutaneous removal remain asymptomatic and may be monitored clinically. Copyright © 2018 SIR. Published by Elsevier Inc. All rights reserved.

  15. Sojourner APXS at Moe - Left Eye

    NASA Image and Video Library

    1999-07-02

    The Sojourner rover's Alpha Proton X-ray Spectrometer (APXS) is shown deployed against the rock "Moe" on the afternoon of Sol 64 (September 7). The rocks to the left of Moe are "Shark" (left of Sojourner) and "Half Dome" (behind Sojourner). They were previously measured by the APXS. The image was taken by the Imager for Mars Pathfinder (IMP). Sojourner spent 83 days of a planned seven-day mission exploring the Martian terrain, acquiring images, and taking chemical, atmospheric and other measurements. The final data transmission received from Pathfinder was at 10:23 UTC on September 27, 1997. Although mission managers tried to restore full communications during the following five months, the successful mission was terminated on March 10, 1998. http://photojournal.jpl.nasa.gov/catalog/PIA01560

  16. Acute Left Arm Ischemia Associated with Floating Thrombus in the Proximal Descending Aorta: Combined Endovascular and Surgical Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fanelli, F., E-mail: fabrizio.fanelli@uniroma1.it; Gazzetti, M.; Boatta, E.

    Free floating thrombus in the proximal descending aorta is an uncommon and dangerous condition that can be associated with acute peripheral embolization. The few cases described were solved with surgical and/or medical therapy. We report the case of a patient with acute left arm ischemia secondary to the presence of floating thrombus in the proximal descending aorta extending into the left subclavian artery, solved with combined endovascular and surgical therapy. Treatment was successfully performed with thrombembolectomy combined with temporary deployment, into the descending aorta, of a Wallstent in a 'basket-fashion' to avoid distal embolization secondary to thrombus fragmentation. At 1more » year follow-up the patient remained symptom-free.« less

  17. Therapeutic efficacy and stent patency of transhepatic portal vein stenting after surgery

    PubMed Central

    Jeon, Ung Bae; Kim, Chang Won; Kim, Tae Un; Choo, Ki Seok; Jang, Joo Yeon; Nam, Kyung Jin; Chu, Chong Woo; Ryu, Je Ho

    2016-01-01

    AIM To evaluate portal vein (PV) stenosis and stent patency after hepatobiliary and pancreatic surgery, using abdominal computed tomography (CT). METHODS Percutaneous portal venous stenting was attempted in 22 patients with significant PV stenosis (> 50%) - after hepatobiliary or pancreatic surgery - diagnosed by abdominal CT. Stents were placed in various stenotic lesions after percutaneous transhepatic portography. Pressure gradient across the stenotic segment was measured in 14 patients. Stents were placed when the pressure gradient across the stenotic segment was > 5 mmHg or PV stenosis was > 50%, as observed on transhepatic portography. Patients underwent follow-up abdominal CT and technical and clinical success, complications, and stent patency were evaluated. RESULTS Stent placement was successful in 21 patients (technical success rate: 95.5%). Stents were positioned through the main PV and superior mesenteric vein (n = 13), main PV (n = 2), right and main PV (n = 1), left and main PV (n = 4), or main PV and splenic vein (n = 1). Patients showed no complications after stent placement. The time between procedure and final follow-up CT was 41-761 d (mean: 374.5 d). Twenty stents remained patent during the entire follow-up. Stent obstruction - caused by invasion of the PV stent by a recurrent tumor - was observed in 1 patient in a follow-up CT performed after 155 d after the procedure. The cumulative stent patency rate was 95.7%. Small in-stent low-density areas were found in 11 (55%) patients; however, during successive follow-up CT, the extent of these areas had decreased. CONCLUSION Percutaneous transhepatic stent placement can be safe and effective in cases of PV stenosis after hepatobiliary and pancreatic surgery. Stents show excellent patency in follow-up abdominal CT, despite development of small in-stent low-density areas. PMID:27956806

  18. Temporary percutaneous T-fastener gastropexy and continuous decompressive gastrostomy in dogs with experimentally induced gastric dilatation.

    PubMed

    Fox-Alvarez, W Alexander; Case, J Brad; Cooke, Kirsten L; Garcia-Pereira, Fernando L; Buckley, Gareth J; Monnet, Eric; Toskich, Beau B

    2016-07-01

    OBJECTIVE To evaluate a percutaneous, continuous gastric decompression technique for dogs involving a temporary T-fastener gastropexy and self-retaining decompression catheter. ANIMALS 6 healthy male large-breed dogs. PROCEDURES Dogs were anesthetized and positioned in dorsal recumbency with slight left-lateral obliquity. The gastric lumen was insufflated endoscopically until tympany was evident. Three T-fasteners were placed percutaneously into the gastric lumen via the right lateral aspect of the abdomen, caudal to the 13th rib and lateral to the rectus abdominis muscle. Through the center of the T-fasteners, a 5F locking pigtail catheter was inserted into the gastric lumen and attached to a device measuring gas outflow and intragastric pressure. The stomach was insufflated to 23 mm Hg, air was allowed to passively drain from the catheter until intraluminal pressure reached 5 mm Hg for 3 cycles, and the catheter was removed. Dogs were hospitalized and monitored for 72 hours. RESULTS Mean ± SD catheter placement time was 3.3 ± 0.5 minutes. Mean intervals from catheter placement to a ≥ 50% decrease in intragastric pressure and to ≤ 6 mm Hg were 2.1 ± 1.3 minutes and 8.4 ± 5.1 minutes, respectively. After catheter removal, no gas or fluid leakage at the catheter site was visible laparoscopically or endoscopically. All dogs were clinically normal 72 hours after surgery. CONCLUSIONS AND CLINICAL RELEVANCE The described technique was performed rapidly and provided continuous gastric decompression with no evidence of postoperative leakage in healthy dogs. Investigation is warranted to evaluate its effectiveness in dogs with gastric dilatation-volvulus.

  19. Treating Refractory Cardiogenic Shock With the TandemHeart and Impella Devices: A Single Center Experience

    PubMed Central

    Schwartz, Bryan G.; Ludeman, Daniel J.; Mayeda, Guy S.; Kloner, Robert A.; Economides, Christina; Burstein, Steven

    2012-01-01

    Background Patients with cardiogenic shock (CS) are routinely treated with intra-aortic balloon pumps (IABPs). The utility of 2 new percutaneous left ventricular assist devices (PLVADs), the Impella and TandemHeart, is unknown. The objective of this study was to describe the use of PLVADs for patients with CS at our institution. Methods All cases involving PLVADs in patients with CS between between January 1, 2008 and June 30, 2010 at a private, tertiary referral hospital were reviewed retrospectively. Results All 76 cases were identified (50 IABP only, 7 Impella, 19 TandemHeart). Most Impella (5/7) and TandemHeart (10/19) patients were initially treated with an IABP before "upgrading" for increased hemodynamic support. All 76 devices (100%) were initiated successfully. Percutaneous revascularization was attempted in 63 patients with angiographic success in 57 (90%). The incidences of major complications were similar between groups, except bleeding occurred less frequently with the IABP. Mean ejection fraction on presentation was 30.4±16.5% and increased by a mean of 6.6±11.4% (P < 0.001). With the institutional approach of treating patients with CS initially with vasopressors and IABPs, then upgrading to an Impella or TandemHeart device for patients refractory to IABP therapy, the overall mortality rate was 40%. Conclusion The Impella and TandemHeart devices can be initiated successfully in patients with CS, are associated with high rates of angiographic success during high risk percutaneous interventions and may benefit the myocardium during myocardial infarction. Randomized trials are warranted investigating use of the Impella and TandemHeart devices in patients with CS and in patients refractory to conventional IABP therapy. PMID:28348673

  20. Percutaneous Transhepatic Endoscopic Holmium Laser Lithotripsy for Intrahepatic and Choledochal Biliary Stones

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rimon, Uri, E-mail: rimonu@sheba.health.gov.il; Kleinmann, Nir; Bensaid, Paul

    2011-12-15

    Purpose: To report our approach for treating complicated biliary calculi by percutaneous transhepatic endoscopic biliary holmium laser lithotripsy (PTBL). Patients and Methods: Twenty-two symptomatic patients (11 men and 11 women, age range 51 to 88 years) with intrahepatic or common bile duct calculi underwent PTBL. Nine patients had undergone previous gastrectomy and small-bowel anastomosis, thus precluding endoscopic retrograde cholangiopancreatography. In the other 13 patients, stone removal attempts by ERCP failed due to failed access or very large calculi. We used a 7.5F flexible ureteroscope and a 200-{mu}m holmium laser fiber by way of a percutaneous transhepatic tract, with graded fluoroscopy,more » to fragment the calculi with direct vision. Balloon dilatation was added when a stricture was seen. The procedure was performed with the patient under general anaesthesia. A biliary drainage tube was left at the end of the procedure. Results: All stones were completely fragmented and flushed into the small bowel under direct vision except for one patient in whom the procedure was aborted. In 18 patients, 1 session sufficed, and in 3 patients, 2 sessions were needed. In 7 patients, balloon dilatation was performed for benign stricture after Whipple operation (n = 3), for choledochalenteric anastomosis (n = 3), and for recurrent cholangitis (n = 1). Adjunctive 'balloon push' (n = 4) and 'rendezvous' (n = 1) procedures were needed to completely clean the biliary tree. None of these patients needed surgery. Conclusion: Complicated or large biliary calculi can be treated successfully using PTBL. We suggest that this approach should become the first choice of treatment before laparoscopic or open surgery is considered.« less

  1. High event rate after a first percutaneous coronary intervention in patients with diabetes mellitus: results from the Swedish coronary angiography and angioplasty registry.

    PubMed

    Ritsinger, Viveca; Saleh, Nawsad; Lagerqvist, Bo; Norhammar, Anna

    2015-06-01

    Patients with diabetes mellitus have reduced longevity after acute coronary syndromes and revascularization. However, knowledge of the long-term complication rates and patterns from an everyday life setting is lacking. Consecutive patients undergoing percutaneous coronary intervention included in the Swedish Coronary Angiography Angioplasty Registry (SCAAR) between 2006 and 2010 and with no previous revascularization were prospectively followed up for combined cardiovascular events (first of all-cause mortality, myocardial infarction, stroke, and heart failure) until December 31, 2010. The mean follow-up period was 920 days (SD, 530 days). Differences in background and procedural characteristics were adjusted for in a multivariate Cox regression model. Of 58 891 patients, mean age 67 years, 19% had diabetes mellitus; 27% of them were on diet treatment, 33% on oral glucose lowering, and 40% on insulin treatment. At admission, cardiovascular risk factors, multiple coronary vessel, and left main stem disease were more frequent in patients with diabetes mellitus and their revascularization was less often complete. The adjusted risk for combined cardiovascular events was higher in patients on insulin (hazard ratio [95% confidence interval], 1.63 [1.55-1.72]), on oral treatment (1.23 [1.15-1.31]), and on diet alone (1.21 [1.12-1.29]) compared with patients without diabetes mellitus. Insulin-treated patients ran an increased risk of restenosis (1.54 [1.39-1.71]) and stent thrombosis (1.56 [1.25-1.96]). The prognosis after a first percutaneous coronary intervention is more severe in patients with diabetes mellitus, in particular, in patients treated with insulin, with higher rates of mortality, cardiovascular events, and stent thrombosis over the following 5 years. © 2015 American Heart Association, Inc.

  2. Effectiveness of percutaneous closure of patent foramen ovale for hypoxemia.

    PubMed

    Fenster, Brett E; Nguyen, Bryant H; Buckner, J Kern; Freeman, Andrew M; Carroll, John D

    2013-10-15

    The aim of this study was to evaluate the ability of percutaneous patent foramen ovale (PFO) closure to improve systemic hypoxemia. Although PFO-mediated right-to-left shunt (RTLS) is associated with hypoxemia, the ability of percutaneous closure to ameliorate hypoxemia is unknown. Between 2004 and 2009, 97 patients who underwent PFO closure for systemic hypoxemia and dyspnea that was disproportionate to underlying lung disease were included for evaluation. All patients exhibited PFO-mediated RTLS as determined by agitated saline echocardiography. Procedural success was defined as implantation of a device without major complications and mild or no residual shunt at 6 months. Clinical success was defined as a composite of an improvement in New York Heart Association (NYHA) functional class, reduction of dyspnea symptoms, or decreased oxygen requirement. Procedural success was achieved in 96 of 97 (99%), and clinical success was achieved in 68 of 97 (70%). The presence of any moderate or severe interatrial shunt by agitated saline study (odds ratio [OR] = 4.7; p <0.024), NYHA class at referral (OR = 2.9; p <0.0087), and 10-year increase in age (OR = 1.8; p <0.0017) increased likelihood of clinical success. In contrast, a pulmonary comorbidity (OR = 0.18; p <0.005) and male gender (OR = 0.30; p <0.017) decreased the likelihood of success. In conclusion, based on the largest single-center experience of patients referred for PFO closure for systemic hypoxemia, PFO closure was a mechanically effective procedure with an associated improvement in echocardiographic evidence of RTLS, NYHA functional class, and oxygen requirement. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Effects of Percutaneous LVAD Support on Right Ventricular Load and Adaptation.

    PubMed

    Yourshaw, Jeffrey P; Mishra, Prabodh; Armstrong, M Christopher; Ramu, Bhavadharini; Craig, Michael L; Van Bakel, Adrian B; Steinberg, Daniel H; DiSalvo, Thomas G; Tedford, Ryan J; Houston, Brian A

    2018-04-30

    Both operative and hemodynamic mechanisms have been implicated in right heart failure (RHF) following surgical left ventricular assist device (LVAD) implantation. We investigated the effects of percutaneous LVAD (pLVAD; Impella®, Abiomed) support on right ventricular (RV) load and adaptation. We reviewed all patients receiving a pLVAD for cardiogenic shock at our institution between July 2014 and April 2017, including only those with pre- and post-pLVAD invasive hemodynamic measurements. Hemodynamic data was recorded immediately prior to pLVAD implantation and up to 96 h post-implantation. Twenty-five patients were included. Cardiac output increased progressively during pLVAD support. PAWP improved early post-pLVAD but did not further improve during continued support. Markers of RV adaptation (right ventricular stroke work index, right atrial pressure (RAP), and RAP to pulmonary artery wedge pressure ratio (RAP:PAWP)) were unchanged acutely implant but progressively improved during continued pLVAD support. Total RV load (pulmonary effective arterial elastance; E A ) and resistive RV load (pulmonary vascular resistance; PVR) both declined progressively. The relationship between RV load and RV adaptation (E A /RAP and E A /RAP:PAWP) was constant throughout. Median vasoactive-inotrope score declined after pLVAD placement and continued to decline throughout support. Percutaneous LVAD support in patients with cardiogenic shock did not acutely worsen RV adaptation, in contrast to previously described hemodynamic effects of surgically implanted durable LVADs. Further, RV load progressively declined during support, and the noted RV adaptation improvement was load-dependent as depicted by constant E A /RA and E A /RAP:PAWP relationships. These findings further implicate the operative changes associated with surgical LVAD implantation in early RHF following durable LVAD.

  4. What explains post-traumatic stress disorder (PTSD) in UK service personnel: deployment or something else?

    PubMed

    Jones, M; Sundin, J; Goodwin, L; Hull, L; Fear, N T; Wessely, S; Rona, R J

    2013-08-01

    In previous studies an association between deployment to Iraq or Afghanistan and an overall increased risk for post-traumatic stress disorder (PTSD) in UK armed forces has not been found. The lack of a deployment effect might be explained by including, in the comparison group, personnel deployed on other operations or who have experienced traumatic stressors unrelated to deployment. The sample comprised 8261 regular UK armed forces personnel who deployed to Iraq, Afghanistan or other operational areas or were not deployed. Participants completed the PTSD CheckList-Civilian Version (PCL-C) and provided information about deployment history, demographic and service factors, serious accidents and childhood experiences. Deployment to Iraq or Afghanistan [odds ratio (OR) 1.2, 95% confidence interval (CI) 0.6-2.2] or elsewhere (OR 1.1, 95% CI 0.6-2.0) was unrelated to PTSD although holding a combat role was associated with PTSD if deployed to Iraq or Afghanistan (OR 2.7, 95% CI 1.9-3.9). Childhood adversity (OR 3.3, 95% CI 2.1-5.0), having left service (OR 2.7, 95% CI 1.9-4.0) and serious accident (OR 2.1, 95% CI 1.4-3.0) were associated with PTSD whereas higher rank was protective (OR 0.3, 95% CI 0.12-0.76). For the majority of UK armed forces personnel, deployment whether to Iraq, Afghanistan or elsewhere confers no greater risk for PTSD than service in the armed forces per se but holding a combat role in those deployed to Iraq or Afghanistan is associated with PTSD. Vulnerability factors such as lower rank, childhood adversity and leaving service, and having had a serious accident, may be at least as important as holding a combat role in predicting PTSD in UK armed forces personnel.

  5. Young man presenting with out-of-hospital cardiac arrest.

    PubMed

    Huang, Hans David; Lombardi, William L; Steinberg, Zachary Louis

    2018-06-22

    A man in his early 30s with remote history of a febrile rash as a toddler presented to the emergency room following an out-of-hospital cardiac arrest while riding his bicycle. He received bystander cardiopulmonary resuscitation and one shock from an automatic external defibrillator, successfully restoring sinus rhythm. On arrival, he was haemodynamically stable without ECG evidence of ST segment changes to suggest active ischaemia, and an initial troponin I was mildly elevated at 0.10 ng/mL (normal <0.04 ng/mL). A CT angiogram (CTA) was obtained showing a normal-appearing aorta and no abnormal extracardiac findings. Urgent coronary angiography was performed; images are shown in figure 1A-C. Echocardiogram revealed a mildly reduced left ventricular ejection fraction (45%) with a hypokinetic inferior wall.heartjnl;heartjnl-2018-312966v1/F1F1F1Figure 1(A) Right coronary artery angiogram in the left anterior oblique cranial projection. (B) Left coronary artery angiogram in the right anterior oblique caudal projection. (C) Left coronary artery angiogram in the right anterior oblique cranial projection. CAUD, caudal; CRAN, cranial; LAO, left anterior oblique; RAO, right anterior oblique. What is the next best step in the management of this patient at this time?Complete revascularisation via percutaneous coronary intervention (PCI).Referral for coronary artery bypass surgery (CABG).Initiation of high-dose steroids.Initiation of dual-antiplatelet therapy without planned revascularisation. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. Endovascular Repair of Acute Symptomatic Pararenal Aortic Aneurysm With Three Chimney and One Periscope Graft for Complete Visceral Artery Revascularization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brechtel, Klaus, E-mail: klaus.brechtel@med.uni-tuebingen.de; Ketelsen, Dominik; Endisch, Andrea

    2012-04-15

    PurposeTo describe a modified endovascular technique for complete revascularization of visceral and renal arteries in symptomatic pararenal aortic aneurysm (PRAA).TechniqueArterial access was surgically established in both common femoral arteries (CFAs) and the left subclavian artery (LSA). Revascularization of the left renal artery, the celiac trunk, and the superior mesenteric artery was performed through one single sheath via the LSA. Suitable covered stents were put in the aortic branches but not deployed. The right renal artery was accessed over the left CFA. Due to the longitudinal extension of the presented aneurysm two stent-grafts were introduced via the right CFA. After deployingmore » the aortic stent-grafts, all covered stents in the side branches were deployed consecutively with a minimum overlap of 5 mm over the cranial and caudal stent-graft edges. Simultaneous ballooning was performed to fully expand all stent-grafts and warranty patency. Conclusion: This is the first report in the literature of chimney grafting in PRAA for complete revascularization of visceral and renal branches by using more than two covered stents introduced from one side through one single sheath. However this technique is modified, it should be used only in bailout situations when branched stent-grafts are not available and/or surgery is not suitable.« less

  7. Astronauts Lovell and Haise during simulation of lunar traverse at Hawaii

    NASA Image and Video Library

    1969-12-01

    S70-20253 (December 1969) --- Astronauts James A. Lovell Jr. (left) commander, and Fred W. Haise Jr., lunar module pilot, carry out a simulation of a lunar traverse at Kilauea, Hawaii, site. Both crew members of NASA's third team of moon explorers were carrying cameras and communications equipment during the simulated traverse. They maintained contact with men in the roles of spacecraft throughout the traverse. Lovell holds a scoop for the Apollo Lunar Hand Tools (ALHT) and a gnomon, also for the ALHT is deployed in front of Haise. The ALHT carrier is at left background, (almost obscured by Lovell).

  8. Management of Suicide-Related Events during Deployment

    DTIC Science & Technology

    2015-02-01

    the supervision of the site PI, Dr. Barbara Stanley. Ms. Emily Biggs , a Master’s level Research assistant, left her position to attend graduate...study progress. The members of the Expert Panel are Lanny Berman, Ph.D., ABPP; Stephen V. Bowles, Ph.D., ABPP; John Bradley, M.D.; Russell B. Carr, M.D

  9. JPRS Report, Near East & South Asia.

    DTIC Science & Technology

    1988-03-30

    to decide suo moto whether the situation was such that they (Armed Forces) should be deployed in the State. However, it was desirable to consult...between the CPI and the CPC, but it is being felt that differences of the past are "best left to the historians ." The relationship between the CPI and

  10. Exploring Ways to Improve DTAG Deployment Success Rates With the ARTS Pneumatic Launcher

    DTIC Science & Technology

    2010-01-01

    absorber system has been developed, (the giraffe leg technique or GL, Figure 2), which has the shock absorbing component in front of the tag. The ARTS...3 Figure 2: the new 1- and 4-spring shock absorbing robot (left) and the GL ( giraffe leg technique) with 3 studs (right) WORK

  11. Pedagogy of the Privileged: Elite Universities and Dialectical Contradictions in the UK

    ERIC Educational Resources Information Center

    Cresswell, Mark; Karimova, Zulfia; Brock, Tom

    2014-01-01

    This paper considers the role and function of Left academics within "elite" (i.e. Russell Group) universities within the UK. Deploying Marxist theory and critical realism, it analyses the "dialectical contradictions" experienced in such a role and reflects upon productive strategies for resisting the hegemony of neo-liberalism…

  12. Ventricular septal rupture, right ventricular dissection, and tricuspid chordae rupture--A rare complication after inferior and right ventricular infarction.

    PubMed

    Li, Xiao-hong; Zhao, Ying; Dong, Jianzeng; He, Yihua; Liu, Wenxu; Han, Jiancheng

    2015-10-01

    A 76-year-old man under stable hemodynamic condition was admitted to our hospital for delayed percutaneous coronary intervention following a diagnosis of acute inferior myocardial infarction. Bedside echocardiography revealed ventricular septal rupture at the basal posteroinferior wall with a large left-to-right shunt. Right ventricular free-wall intramyocardial dissection and tricuspid chordae rupture were noted. Coronary angiography demonstrated occlusion of the proximal right coronary artery, which was treated by balloon angioplasty and stenting. While preparing for surgical repair, the patient's overall cardiac and renal function deteriorated and surgery was contraindicated. The patient died 16 days after discharge. © 2014 Wiley Periodicals, Inc.

  13. Morphometric study of the true S1 and S2 of the normal and dysmorphic sacralized sacra.

    PubMed

    Firat, Ayşegül; Alemdaroğlu, Kadir Bahadır; Özmeriç, Ahmet; Yücens, Mehmet; Göksülük, Dinçer

    2017-06-12

    This study aimed to generate data for the S1 and S2 alar pedicle and body and the alar orientations for both dysmorphic and normal sacra. The study comprised two groups: Group N consisted of 53 normal sacra and Group D included 10 dysmorphic sacra. Various features such as alar pedicle circumference; anterior, middle, and posterior axis of the sacral ala; sacral body height and width; and sagittal thickness were measured. In group N, the median anterior axis of the alae was observed to be 30° on the right and 25° on the left, the median midline axis was found to be 20° on the right and 15° on the left, and the median posterior alar axis was -15° on the right and -20° on the left. The true S1 and S2 alar pedicle circumferences were observed to be significantly smaller in group D, which demonstrated a shorter S1 alar pedicle mean circumference, significantly narrower S1 body mean width, and considerably tapered sagittal thickness. Our analysis indicated that dysmorphic sacra have a lower sagittal thickness and width of bodies and smaller alar pedicles, which explains the difficulties in their percutaneous fixation.

  14. Guidelines for the Use of Echocardiography in the Evaluation of a Cardiac Source of Embolism.

    PubMed

    Saric, Muhamed; Armour, Alicia C; Arnaout, M Samir; Chaudhry, Farooq A; Grimm, Richard A; Kronzon, Itzhak; Landeck, Bruce F; Maganti, Kameswari; Michelena, Hector I; Tolstrup, Kirsten

    2016-01-01

    Embolism from the heart or the thoracic aorta often leads to clinically significant morbidity and mortality due to transient ischemic attack, stroke or occlusion of peripheral arteries. Transthoracic and transesophageal echocardiography are the key diagnostic modalities for evaluation, diagnosis, and management of stroke, systemic and pulmonary embolism. This document provides comprehensive American Society of Echocardiography guidelines on the use of echocardiography for evaluation of cardiac sources of embolism. It describes general mechanisms of stroke and systemic embolism; the specific role of cardiac and aortic sources in stroke, and systemic and pulmonary embolism; the role of echocardiography in evaluation, diagnosis, and management of cardiac and aortic sources of emboli including the incremental value of contrast and 3D echocardiography; and a brief description of alternative imaging techniques and their role in the evaluation of cardiac sources of emboli. Specific guidelines are provided for each category of embolic sources including the left atrium and left atrial appendage, left ventricle, heart valves, cardiac tumors, and thoracic aorta. In addition, there are recommendation regarding pulmonary embolism, and embolism related to cardiovascular surgery and percutaneous procedures. The guidelines also include a dedicated section on cardiac sources of embolism in pediatric populations. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  15. Do Indo-Asians have smaller coronary arteries?

    PubMed

    Lip, G Y; Rathore, V S; Katira, R; Watson, R D; Singh, S P

    1999-08-01

    There is a widespread belief that coronary arteries are smaller in Indo-Asians. The aim of the present study was to compare the size of atheroma-free proximal and distal epicardial coronary arteries of Indo-Asians and Caucasians. We analysed normal coronary angiograms from 77 Caucasians and 39 Indo-Asians. The two groups were comparable for dominance of the coronary arteries. Indo-Asian patients had generally smaller coronary arteries, with a statistically significant difference in the mean diameters of the left main coronary artery, proximal, mid and left anterior descending, and proximal and distal right coronary artery segments. There was a non-significant trend towards smaller coronary artery segment diameters for the distal left anterior descending, proximal and distal circumflex, and obtuse marginal artery segments. However, after correction for body surface area, none of these differences in size were statistically significant. Thus, the smaller coronary arteries in Indo-Asian patients were explained by body size alone and were not due to ethnic origin per se. This finding nevertheless has important therapeutic implications, since smaller coronary arteries may give rise to technical difficulties during bypass graft and intervention procedures such as percutaneous transluminal coronary angioplasty, stents and atherectomy. On smaller arteries, atheroma may also give an impression of more severe disease than on larger diameter arteries.

  16. Cardiac surgery or interventional cardiology? Why not both? Let's go hybrid.

    PubMed

    Papakonstantinou, Nikolaos A; Baikoussis, Nikolaos G; Dedeilias, Panagiotis; Argiriou, Michalis; Charitos, Christos

    2017-01-01

    A hybrid strategy, firstly performed in the 1990s, is a combination of tools available only in the catheterization laboratory with those available only in the operating room in order to minimize surgical morbidity and face with any cardiovascular lesion. The continuous evolution of stent technology along with the adoption of minimally invasive surgical approaches, make hybrid approaches an attractive alternative to standard surgical or transcatheter techniques for any given set of cardiovascular lesions. Examples include hybrid coronary revascularization, when an open surgical anastomosis of the left internal mammary artery to the left anterior descending coronary artery is performed along with stent implantation in non-left anterior descending coronary vessels, open heart valve surgery combined with percutaneous coronary interventions to coronary lesions, hybrid aortic arch debranching combined with endovascular grafting for thoracic aortic aneurysms, hybrid endocardial and epicardial atrial fibrillation procedures, and carotid artery stenting along with coronary artery bypass grafting. The cornerstone of success for all of these methods is the productive collaboration between cardiac surgeons and interventional cardiologists. The indications and patient selection of these procedures are still to be defined. However, high-risk patients have already been shown to benefit from hybrid approaches. Copyright © 2016 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  17. Interhospital air transport of a blind patient on extracorporeal life support with consecutive and successful left ventricular assist device implantation.

    PubMed

    Bauer, Adrian; Schaarschmidt, Jan; Grosse, F Oliver; Al Alam, Nidal; Hausmann, Harald; Krämer, Klaus; Strüber, Martin; Mohr, Friedrich W

    2014-06-01

    The use of extracorporeal life support systems (ECLS) in patients with postcardiotomy low cardiac output syndrome (LCO) as a bridge to recovery and bridge to implantation of ventricular assist device (VAD) is common nowadays. A 59-year-old patient with acute myocardial infarction received a percutaneous transluminal angioplasty and stenting of the circumflex artery. During catheterization of the left coronary artery (LAD), the patient showed ventricular fibrillation and required defibrillation and cardiopulmonary resuscitation. After implantation of an intra-aortic balloon pump, the patient immediately was transmitted to the operating room. He received emergency coronary artery bypass grafting in a beating heart technique using pump-assisted minimal extracorporeal circulation circuit (MECC). Two bypass grafts were performed to the LAD and the right posterior descending artery. Despite initial successful weaning off cardiopulmonary bypass with high-dose inotropic support, the patient presented postcardiotomy LCO and an ECLS was implanted. The primary setup of the heparin-coated MECC system was modified and used postoperatively. As a result of the absence of an in-house VAD program, the patient was switched to a transportable ECLS the next day and was transferred by helicopter to the nearest VAD center where the patient received a successful insertion of a left VAD 3 days later.

  18. Role of cardiac imaging and three-dimensional printing in percutaneous appendage closure.

    PubMed

    Iriart, Xavier; Ciobotaru, Vlad; Martin, Claire; Cochet, Hubert; Jalal, Zakaria; Thambo, Jean-Benoit; Quessard, Astrid

    2018-06-06

    Atrial fibrillation is the most frequent cardiac arrhythmia, affecting up to 13% of people aged>80 years, and is responsible for 15-20% of all ischaemic strokes. Left atrial appendage occlusion devices have been developed as an alternative approach to reduce the risk of stroke in patients for whom oral anticoagulation is contraindicated. The procedure can be technically demanding, and obtaining a complete left atrial appendage occlusion can be challenging. These observations have emphasized the importance of preprocedural planning, to optimize the accuracy and safety of the procedure. In this setting, a multimodality imaging approach, including three-dimensional imaging, is often used for preoperative assessment and procedural guidance. These imaging modalities, including transoesophageal echocardiography and multislice computed tomography, allow acquisition of a three-dimensional dataset that improves understanding of the cardiac anatomy; dedicated postprocessing software integrated into the clinical workflow can be used to generate a stereolithography file, which can be printed in a rubber-like material, seeking to replicate the myocardial tissue characteristics and mechanical properties of the left atrial appendage wall. The role of multimodality imaging and 3D printing technology offers a new field for implantation simulation, which may have a major impact on physician training and technique optimization. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  19. Percutaneous coronary intervention versus coronary artery bypass grafting: where are we after NOBLE and EXCEL?

    PubMed

    Fortier, Jacqueline H; Shaw, Richard E; Glineur, David; Grau, Juan B

    2017-11-01

    The publication of the NOBLE and EXCEL trials, with seemingly conflicting results, brought into question whether percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG) is better for low-risk patients with left main coronary artery stenosis (LMCAS). This review appraises the methods and results of NOBLE and EXCEL, contextualizes them within the literature, and determines how they may affect clinical practice. We appraised the trials and describe differences in methodology and results. NOBLE recruited primarily isolated LMCAS, and found that CABG was superior to PCI. EXCEL's population included patients LMCAS in the context of multivessel CAD, and found PCI and CABG were comparable. Both trials enrolled young patients with few comorbidities, and there was more protocol-mandated consistency in the procedural techniques and medical therapy of patients receiving PCI. The generalizability of these trials is limited by the use of young, healthy patients at highly skilled centres that rarely reflect typical clinical practice. If these studies are to maintain relevance, trialists must address the lack of protocolization of surgical interventions and inconsistent medical therapies. Unfortunately, the limitations of NOBLE and EXCEL mean that we are no closer to answering the question of what is the optimal treatment for patients with LMCAS.

  20. Real-time adjustment of ventricular restraint therapy in heart failure.

    PubMed

    Ghanta, Ravi K; Lee, Lawrence S; Umakanthan, Ramanan; Laurence, Rita G; Fox, John A; Bolman, Ralph Morton; Cohn, Lawrence H; Chen, Frederick Y

    2008-12-01

    Current ventricular restraint devices do not allow for either the measurement or adjustment of ventricular restraint level. Periodic adjustment of restraint level post-device implantation may improve therapeutic efficacy. We evaluated the feasibility of an adjustable quantitative ventricular restraint (QVR) technique utilizing a fluid-filled polyurethane epicardial balloon to measure and adjust restraint level post-implantation guided by physiologic parameters. QVR balloons were implanted in nine ovine with post-infarction dilated heart failure. Restraint level was defined by the maximum restraint pressure applied by the balloon to the epicardium at end-diastole. An access line connected the balloon lumen to a subcutaneous portacath to allow percutaneous access. Restraint level was adjusted while left ventricular (LV) end-diastolic volume (EDV) and cardiac output was assessed with simultaneous transthoracic echocardiography. All nine ovine successfully underwent QVR balloon implantation. Post-implantation, restraint level could be measured percutaneously in real-time and dynamically adjusted by instillation and withdrawal of fluid from the balloon lumen. Using simultaneous echocardiography, restraint level could be adjusted based on LV EDV and cardiac output. After QVR therapy for 21 days, LV EDV decreased from 133+/-15 ml to 113+/-17 ml (p<0.05). QVR permits real-time measurement and physiologic adjustment of ventricular restraint therapy after device implantation.

  1. Anatomic Suitability for Transcaval Access Based on Computed Tomography.

    PubMed

    Lederman, Robert J; Greenbaum, Adam B; Rogers, Toby; Khan, Jaffar M; Fusari, Melissa; Chen, Marcus Y

    2017-01-09

    Transcaval access has been used successfully for over 200 transcatheter aortic valve replacements, large-bore percutaneous left ventricular assist devices, and thoracic endovascular aortic aneurysm repairs. This review teaches how to plan transcaval access and closure based on computed tomography. The main planning goals are to: 1) identify calcium-free crossing targets in the abdominal aorta along with optimal fluoroscopic projection angles and level with respect to lumbar vertebrae; 2) identify obstacles such as interposed bowel or pedunculated aortic atheroma; 3) plan covered stent bailout; and 4) identify jeopardized vascular branches such as renal arteries that might be obstructed by bailout covered stents if employed. The aorta and inferior vena cava are segmented (sculpted) using an image reconstruction workstation and crossing targets are highlighted. Important measurements such as aortic lumen diameter and target distance from renal arteries, aortoiliac bifurcation, and right femoral vein puncture site are reported to assist the operator. The proposed classification for transcaval feasibility has been revised, making some previously unfavorable candidates now feasible or favorable based on procedural success to date. Transcaval access allows percutaneous introduction of large devices into the aorta despite small or diseased iliofemoral arteries. By following these simplified procedures, both operators and imaging specialists can easily prepare comprehensive treatment plans. Copyright © 2017 American College of Cardiology Foundation. All rights reserved.

  2. Association Between Contrast Media Volume-Glomerular Filtration Rate Ratio and Contrast-Induced Acute Kidney Injury After Primary Percutaneous Coronary Intervention.

    PubMed

    Celik, Omer; Ozturk, Derya; Akin, Fatih; Ayca, Burak; Yalcın, Ahmet Arif; Erturk, Mehmet; Bıyık, Ismail; Ayaz, Ahmet; Akturk, Ibrahim Faruk; Enhos, Asım; Aslan, Serkan

    2015-07-01

    We hypothesized that contrast media volume-estimated glomerular filtration rate (CV-e-GFR) ratio may be a predictor of contrast media-induced acute kidney injury (CI-AKI). We investigated the associations between CV-e-GFR ratio and CI-AKI in 597 patients undergoing primary percutaneous coronary intervention (pPCI). An absolute ≥0.3 mg/dL increase in serum creatinine compared with baseline levels within 48 hours after the procedure was considered as CI-AKI; 78 (13.1%) of the 597 patients experienced CI-AKI. The amount of contrast during procedure was higher in the CI-AKI group than in those without CI-AKI (153 vs 135 mL, P = .003). The CV-e-GFR ratio was significantly higher in patients with CI-AKI than without (2.3 vs 1.5, P < .001). In multivariate analysis, independent predictors of CI-AKI were low left ventricular ejection fraction (P = .018, odds ratio [OR] = 0.966), e-GFR <60 mL/min (P = .012, OR = 2.558), and CV-e-GFR >2 (P < .001, OR = 5.917). In conclusion, CV-e-GFR ratio is significantly associated with CI-AKI after pPCI. © The Author(s) 2014.

  3. Enhancing Outcomes for Outpatient Percutaneous Coronary Interventions

    PubMed Central

    Spruce, Kevin; Butler, Chondra

    2017-01-01

    Purpose and Objectives: A quality improvement project was conducted to create a sustainable continuum of care for increased volumes of outpatients receiving percutaneous coronary interventions. Dramatic growth exposed system vulnerabilities and left staff overwhelmed. Four postinterventional project objectives included reducing preprocedural preparation times, reducing bleeding complications, reducing hospital length of stay, and collectively increasing patient satisfaction. Description of the Project: Amidst creating a specialized postintervention coronary recovery area and acquiring and training existing preregistration and recovery nurses, a fragmented system of care was united. The clinical nurse specialist–led project used a systematic and evidence-based implementation process to harmoniously acclimate perioperative staff. An evaluation process further defined new opportunities to support a growing service line. Outcomes: Postimplementation data were collected over a 3-month period. An overall improvement was found in all targeted objectives, despite an upsurge in case volumes. A moderately significant correlation (r [105] = 0.424, P < .001) was found between bleeding occurrences and hospital length of stay. Conclusion: The synergy between interdepartmental collaboration and strategic staffing reallocation was shown to be invaluable to alleviate procedural areas of service, such as the cardiac catheterization laboratory. As a project champion, the clinical nurse specialist is an essential catalyst to identify and creatively surmount system-level challenges. PMID:28991015

  4. Advancements in mechanical circulatory support for patients in acute and chronic heart failure

    PubMed Central

    Csepe, Thomas A.

    2017-01-01

    Cardiogenic shock (CS) continues to have high mortality and morbidity despite advances in pharmacological, mechanical, and reperfusion approaches to treatment. When CS is refractory to medical therapy, percutaneous mechanical circulatory support (MCS) should be considered. Acute MCS devices, ranging from intra-aortic balloon pumps (IABPs) to percutaneous temporary ventricular assist devices (VAD) to extracorporeal membrane oxygenation (ECMO), can aid, restore, or maintain appropriate tissue perfusion before the development of irreversible end-organ damage. Technology has improved patient survival to recovery from CS, but in patients whom cardiac recovery does not occur, acute MCS can be effectively utilized as a bridge to long-term MCS devices and/or heart transplantation. Heart transplantation has been limited by donor heart availability, leading to a greater role of left ventricular assist device (LVAD) support. In patients with biventricular failure that are ineligible for LVAD implantation, further advancements in the total artificial heart (TAH) may allow for improved survival compared to medical therapy alone. In this review, we discuss the current state of acute and durable MCS, ongoing advances in LVADs and TAH devices, improved methods of durable MCS implantation and patient selection, and future MCS developments in this dynamic field that may allow for optimization of HF treatment. PMID:29268418

  5. Ventricular Septal Perforation after Biventricular Takotsubo Cardiomyopathy Successfully Repaired with an Amplatzer Device: First Report in the Literature.

    PubMed

    Rodríguez, Alfredo E; Fernandez-Pereira, Carlos; Mieres, Juan; Ascarrunz, Diego; Gabe, Eduardo; Rodríguez-Granillo, Alfredo Matías; Frattini, Romina; Stuzbach, Pablo

    2016-01-01

    A 79-year-old female was admitted with sudden onset dyspnea, mild oppressive chest pain, and severe anxiety disorder. Patient had history of hypertension, dyslipidemia, smoking, and chronic obstructive pulmonary disease. On admission blood pressure was 160/90 and heart rate was 130 bpm. Transthoracic echocardiography (TE) and contrast tomography showed a thin septum with an abnormal left and right ventricular contraction with an "apical ballooning" pattern and mild increase of cardiac enzymes. At the 4th day of admission, the patient presented symptoms and signs of congestive heart failure and developed cardiogenic shock. EKG showed an inversion of T waves in all precordial leads. In a new TE, a ventricular septal perforation (VSP) in the apical portion of the septum was seen. Coronary angiogram showed angiographically "normal" coronary arteries. With a diagnosis of VSP in takotsubo cardiomyopathy, a percutaneous procedure to repair the VSP was performed 11 days after admission. The VSP was closed with an Amplatzer device. TE performed 24 hours after showed significant improvement of ventricular function and good apposition of the Amplatzer device. Three days later she was discharged from the hospital. To our knowledge, this is the first reported case of a VSP in a TCM repaired percutaneously with an occluder device.

  6. Real-time magnetic resonance imaging-guided transcatheter aortic valve replacement.

    PubMed

    Miller, Justin G; Li, Ming; Mazilu, Dumitru; Hunt, Tim; Horvath, Keith A

    2016-05-01

    To demonstrate the feasibility of Real-time magnetic resonance imaging (rtMRI) guided transcatheter aortic valve replacement (TAVR) with an active guidewire and an MRI compatible valve delivery catheter system in a swine model. The CoreValve system was minimally modified to be MRI-compatible by replacing the stainless steel components with fluoroplastic resin and high-density polyethylene components. Eight swine weighing 60-90 kg underwent rtMRI-guided TAVR with an active guidewire through a left subclavian approach. Two imaging planes (long-axis view and short-axis view) were used simultaneously for real-time imaging during implantation. Successful deployment was performed without rapid ventricular pacing or cardiopulmonary bypass. Postdeployment images were acquired to evaluate the final valve position in addition to valvular and cardiac function. Our results show that the CoreValve can be easily and effectively deployed through a left subclavian approach using rtMRI guidance, a minimally modified valve delivery catheter system, and an active guidewire. This method allows superior visualization before deployment, thereby allowing placement of the valve with pinpoint accuracy. rtMRI has the added benefit of the ability to perform immediate postprocedural functional assessment, while eliminating the morbidity associated with radiation exposure, rapid ventricular pacing, contrast media renal toxicity, and a more invasive procedure. Use of a commercially available device brings this rtMRI-guided approach closer to clinical reality. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  7. Early Postoperative Results of Percutaneous Needle Fasciotomy in 451 Patients with Dupuytren Disease.

    PubMed

    Molenkamp, Sanne; Schouten, Tanneke A M; Broekstra, Dieuwke C; Werker, Paul M N; Moolenburgh, J Daniel

    2017-06-01

    Percutaneous needle fasciotomy is a minimally invasive treatment modality for Dupuytren disease. In this study, the authors analyzed the efficacy and complication rate of percutaneous needle fasciotomy using a statistical method that takes the multilevel structure of data, regarding multiple measurements from the same patient, into account. The data of 470 treated rays from 451 patients with Dupuytren disease that underwent percutaneous needle fasciotomy were analyzed retrospectively. The authors described the early postoperative results of percutaneous needle fasciotomy and applied linear mixed models to compare mean correction of passive extension deficit between joints and efficacy of primary versus secondary percutaneous needle fasciotomy. Mean preoperative passive extension deficits at the metacarpophalangeal, proximal interphalangeal, and distal interphalangeal joints were 37, 40, and 31 degrees, respectively. Mean preoperative total passive extension deficit was 54 degrees. Results were excellent, with a mean total passive extension deficit correction of 85 percent. Percutaneous needle fasciotomy was most effective for metacarpophalangeal joints and less effective for proximal interphalangeal and distal interphalangeal joints. Secondary percutaneous needle fasciotomy was as effective as primary percutaneous needle fasciotomy. Complications were rare and mostly minor. The results of this study confirm that percutaneous needle fasciotomy is an effective and safe treatment modality for patients with mild to moderate disease who prefer a minimally invasive procedure. Therapeutic, IV.

  8. The ACUSITT ultrasonic ablator: the first steerable needle with an integrated interventional tool

    NASA Astrophysics Data System (ADS)

    Burdette, E. Clif; Rucker, D. Caleb; Prakash, Punit; Diederich, Chris J.; Croom, Jordon M.; Clarke, Clyde; Stolka, Philipp; Juang, Titania; Boctor, Emad M.; Webster, Robert J., III

    2010-03-01

    Steerability in percutaneous medical devices is highly desirable, enabling a needle or needle-like instrument to avoid sensitive structures (e.g. nerves or blood vessels), access obstructed anatomical targets, and compensate for the inevitable errors induced by registration accuracy thresholds and tissue deformation during insertion. Thus, mechanisms for needle steering have been of great interest in the engineering community in the past few years, and several have been proposed. While many interventional applications have been hypothesized for steerable needles (essentially anything deliverable via a regular needle), none have yet been demonstrated as far as the authors are aware. Instead, prior studies have focused on model validation, control, and accuracy assessment. In this paper, we present the first integrated steerable needle-interventional device. The ACUSITT integrates a multi-tube steerable Active Cannula (AC) with an Ultrasonic Interstitial Thermal Therapy ablator (USITT) to create a steerable percutaneous device that can deliver a spatially and temporally controllable (both mechanically and electronically) thermal dose profile. We present our initial experiments toward applying the ACUSITT to treat large liver tumors through a single entry point. This involves repositioning the ablator tip to several different locations, without withdrawing it from the liver capsule, under 3D Ultrasound image guidance. In our experiments, the ACUSITT was deployed to three positions, each 2cm apart in a conical pattern to demonstrate the feasibility of ablating large liver tumors 7cm in diameter without multiple parenchyma punctures.

  9. Exploring Geographic Disparities in Broadband Access and Use in Rural Southern Illinois: Who's Being Left behind?

    ERIC Educational Resources Information Center

    Oyana, Tonny J.

    2011-01-01

    Recent literature about broadband telecommunications reveals two major areas that are not only globally gaining prominence, but are also demanding urgent attention from a research perspective. One of the key areas is related to the need to spatially evaluate the availability and deployment of broadband services, especially among urban versus rural…

  10. Getting to the Left of Sharp: Lessons Learned from West Point’s Efforts to Combat Sexual Harassment and Assault

    DTIC Science & Technology

    2015-01-01

    the same standards to pornographic materials in those spaces that they would in other work areas. This is clearly a sensitive area, but ample...precedent exists: General Order #1 for deployed forces prohibits purchasing, producing, or displaying any pornographic or sexu- ally explicit material

  11. In vitro comparison of support capabilities of intra-aortic balloon pump and Impella 2.5 left percutaneous.

    PubMed

    Schampaert, Stéphanie; van't Veer, Marcel; van de Vosse, Frans N; Pijls, Nico H J; de Mol, Bas A; Rutten, Marcel C M

    2011-09-01

    The Impella 2.5 left percutaneous (LP), a relatively new transvalvular assist device, challenges the position of the intra-aortic balloon pump (IABP), which has a long record in supporting patients after myocardial infarction and cardiac surgery. However, while more costly and more demanding in management, the advantages of the Impella 2.5 LP are yet to be established. The aim of this study was to evaluate the benefits of the 40 cc IABP and the Impella 2.5 LP operating at 47,000 rpm in vitro, and compare their circulatory support capabilities in terms of cardiac output, coronary flow, cardiac stroke work, and arterial blood pressure. Clinical scenarios of cardiogenic preshock and cardiogenic shock (CS), with blood pressure depression, lowered cardiac output, and constant heart rate of 80 bpm, were modeled in a model-controlled mock circulation, featuring a systemic, pulmonary, and coronary vascular bed. The ventricles, represented by servomotor-operated piston pumps, included the Frank-Starling mechanism. The systemic circulation was modeled with a flexible tube having close-to-human aortic dimensions and compliance properties. Proximally, it featured a branch mimicking the brachiocephalic arteries and a physiological correct coronary flow model. The rest of the systemic and pulmonary impedance was modeled by four-element Windkessel models. In this system, the enhancement of coronary flow and blood pressure was tested with both support systems under healthy and pathological conditions. Hemodynamic differences between the IABP and the Impella 2.5 LP were small. In our laboratory model, both systems approximately yielded a 10% cardiac output increase and a 10% coronary flow increase. However, since the Impella 2.5 LP provided significantly better left ventricular unloading, the circulatory support capabilities were slightly in favor of the Impella 2.5 LP. On the other hand, pulsatility was enhanced with the IABP and lowered with the Impella 2.5 LP. The support capabilities of both the IABP and the Impella 2.5 LP strongly depended on the simulated hemodynamic conditions. Maximum hemodynamic benefits were achieved when mechanical circulatory support was applied on a simulated scenario of deep CS. © 2011, Copyright Eindhoven University of Technology (TU/e). Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  12. Comparison by meta-analysis of percutaneous coronary intervention versus coronary artery bypass grafting in patients with a mean age of ≥70 years.

    PubMed

    Alam, Mahboob; Virani, Salim S; Shahzad, Saima A; Siddiqui, Sahar; Siddiqui, Khaleeq H; Mumtaz, Shahzad A; Kleiman, Neal S; Coselli, Joseph S; Lakkis, Nasser M; Jneid, Hani

    2013-09-01

    A paucity of published data evaluating the outcomes of older patients (age ≥70 years) undergoing revascularization for unprotected left main coronary artery disease is available. We performed aggregate data meta-analyses of the clinical outcomes (all-cause mortality, nonfatal myocardial infarction, stroke, repeat revascularization, and major adverse cardiac and cerebrovascular events at 30 days and 12 and 22 months) in studies comparing percutaneous coronary intervention (PCI) and coronary artery bypass grafting (CABG) in patients with a mean age of ≥70 years and unprotected left main coronary artery disease. A comprehensive, time-unlimited literature search to January 31, 2013 identified 10 studies with a total of 2,386 patients (PCI, n = 909; CABG, n = 1,477). Summary odds ratios (ORs) and 95% confidence intervals (CIs) were estimated using the random-effects model. The patients in the PCI group were more likely than those in the CABG group to present with acute coronary syndrome (59.6% vs 44.8%, p <0.001). PCI was associated with a shorter hospital stay (4.2 ± 0.8 vs 8.3 ± 0.01 days, p <0.001). No significant differences were found between PCI and CABG for all cause-mortality, nonfatal myocardial infarction, and major adverse cardiac and cerebrovascular events at 30 days and 12 and 22 months. However, PCI was associated with lower rates of stroke at 30 days (OR 0.14, 95% CI 0.02 to 0.76) and 12 months (OR 0.14, 95% CI 0.03 to 0.60) and higher rates of repeat revascularization at 22 months (OR 4.34, 95% CI 2.69 to 7.01). These findings were consistent with the findings from a subgroup analysis of patients aged ≥75 years. In conclusion, older patients (age ≥70 years) with unprotected left main coronary artery disease had comparable rates of all-cause mortality, nonfatal myocardial infarction, and major adverse cardiac and cerebrovascular events after PCI or CABG. The patients undergoing PCI had a shorter hospital stay and lower rates of early stroke; however, they experienced higher repeat revascularization rates at longer term follow-up. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. Stepwise approach to curative surgery using percutaneous transhepatic cholangiodrainage and portal vein embolization for severe bile duct injury during laparoscopic cholecystectomy: a case report.

    PubMed

    Honmyo, Naruhiko; Kuroda, Shintaro; Kobayashi, Tsuyoshi; Ishiyama, Kohei; Ide, Kentaro; Tahara, Hiroyuki; Ohira, Masahiro; Ohdan, Hideki

    2016-12-01

    Laparoscopic cholecystectomy (LC) has been recently adapted to acute cholecystitis. Major bile duct injury during LC, especially Strasberg-Bismuth classification type E, can be a critical problem sometimes requiring hepatectomy. Safety and definitive treatment without further morbidities, such as posthepatectomy liver failure, is required. Here, we report a case of severe bile duct injury treated with a stepwise approach using (99m)Tc-galactosyl human serum albumin ((99m)Tc-GSA) single-photon emission computed tomography (SPECT)/CT fusion imaging to accurately estimate liver function.A 52-year-old woman diagnosed with acute cholecystitis underwent LC at another hospital and was transferred to our university hospital for persistent bile leakage on postoperative day 20. She had no jaundice or infection, although an intraperitoneal drainage tube discharged approximately 500 ml of bile per day. Recorded operation procedure showed removal of the gallbladder with a part of the common bile duct due to its misidentification, and each of the hepatic ducts and right hepatic artery was injured. Abdominal enhanced CT revealed obstructive jaundice of the left liver and arterial shunt through the hilar plate to the right liver. Magnetic resonance cholangiopancreatography revealed type E4 or more advanced bile duct injury according to the Bismuth-Strasberg classification. We planned a stepwise approach using percutaneous transhepatic cholangiodrainage (PTCD) and portal vein embolization (PVE) for secure right hemihepatectomy and biliary-jejunum reconstruction and employed (99m)Tc-GSA SPECT/CT fusion imaging to estimate future remnant liver function. The left liver function rate had changed from 26.2 % on admission to 26.3 % after PTCD and 54.5 % after PVE, while the left liver volume rate was 33.8, 33.3, and 49.6 %, respectively. The increase of liver function was higher than that of volume (28.3 vs. 15.8 %). On postoperative day 63, the curative operation, right hemihepatectomy and biliary-jejunum reconstruction, was performed, and posthepatectomy liver failure could be avoided.Careful consideration of treatment strategy for each case is necessary for severe bile duct injury with arterial injury requiring hepatectomy. The stepwise approach using PTCD and PVE could enable hemihepatectomy, and (99m)Tc-GSA SPECT/CT fusion imaging was useful to estimate heterogeneous liver function.

  14. Left anterior descending/right coronary artery as culprit arteries in acute myocardial infarction (n=2011) in changing physical environment, percutaneous coronary intervention data, 2000-2010.

    PubMed

    Stoupel, Eliyahu; Abramson, Evgeny; Israelevich, Peter

    2011-11-02

    Percutaneous coronary intervention (PCI) is one of the principal treatments of acute coronary syndrome (ACS), including acute myocardial infarction (AMI). This treatment largely expanded our knowledge on the pathophysiology of AMI and related coronary pathologies. Recent studies found a significant relationship of the timing of ACS with environmental physical activity: solar (SA), geomagnetic (GMA) and cosmic ray (CRA) activity. The aim of this study was to examine if the interrelationship of two principal culprit arteries, left anterior descending (LAD) and right coronary artery (RCA), are involved in the pathogenesis of AMI in different daily levels of GMA and CRA. Patients undergoing PCI for AMI on the day of symptoms of the disease (n=2011, 79.9% males) in the Rabin Medical Center in the years 2000-2010 were studied. The culprit arteries, LAD and RCA, correlated to AMI in zero and I0-IV0 of daily GMA and inversely to GMA related CRA (measured by neutron activity on the earth surface) and their ratio was compared. LAD (45.0%) and RCA (35.7%) were the main culprit arteries in AMI. LAD/RCA ratio increased inversely to GMA (zero=IV0, r=-0.94, p=0.017) and in correlation with daily neutron activity for LAD (r=0.97, p=0.03) and RCA (r=0.95, p=0.04). LAD/RCA ratio was 1 in IV0 of GMA (28% increase) and steadily increased to 1.62 (62% difference) at zero GMA (r=-0.94, p=0.0117), and increasing neutron activity was accompanied by increasing LAD involvement as a culprit artery in AMI. High daily neutron activity and low GMA are accompanied by increasing LAD as a culprit artery in AMI. The possible mechanisms of this finding are discussed.

  15. Placement of iliosacral screws using 3D image-guided (O-Arm) technology and Stealth Navigation: comparison with traditional fluoroscopy.

    PubMed

    Theologis, A A; Burch, S; Pekmezci, M

    2016-05-01

    We compared the accuracy, operating time and radiation exposure of the introduction of iliosacral screws using O-arm/Stealth Navigation and standard fluoroscopy. Iliosacral screws were introduced percutaneously into the first sacral body (S1) of ten human cadavers, four men and six women. The mean age was 77 years (58 to 85). Screws were introduced using a standard technique into the left side of S1 using C-Arm fluoroscopy and then into the right side using O-Arm/Stealth Navigation. The radiation was measured on the surgeon by dosimeters placed under a lead thyroid shield and apron, on a finger, a hat and on the cadavers. There were no neuroforaminal breaches in either group. The set-up time for the O-Arm was significantly longer than for the C-Arm, while total time for placement of the screws was significantly shorter for the O-Arm than for the C-Arm (p = 0.001). The mean absorbed radiation dose during fluoroscopy was 1063 mRad (432.5 mRad to 4150 mRad). No radiation was detected on the surgeon during fluoroscopy, or when he left the room during the use of the O-Arm. The mean radiation detected on the cadavers was significantly higher in the O-Arm group (2710 mRem standard deviation (sd) 1922) than during fluoroscopy (11.9 mRem sd 14.8) (p < 0.01). O-Arm/Stealth Navigation allows for faster percutaneous placement of iliosacral screws in a radiation-free environment for surgeons, albeit with the same accuracy and significantly more radiation exposure to cadavers, when compared with standard fluoroscopy. Placement of iliosacral screws with O-Arm/Stealth Navigation can be performed safely and effectively. Cite this article: Bone Joint J 2016;98-B:696-702. ©2016 The British Editorial Society of Bone & Joint Surgery.

  16. Electrical alternans induced by a brief period of myocardial ischemia during percutaneous coronary intervention: The characteristic ECG morphology and relationship to mechanical alternans.

    PubMed

    Oguro, Takeo; Fujii, Masatsune; Fuse, Koichi; Takahashi, Minoru; Fujita, Satoru; Kitazawa, Hitoshi; Sato, Masahito; Ikeda, Yoshio; Okabe, Masaaki; Aizawa, Yoshifusa

    2015-11-01

    Electrical alternans (EA) has not been fully studied in the current percutaneous coronary intervention (PCI) procedure. The purpose of this study was to evaluate visible EA and the morphology of ST segment during PCI. The incidence of visible EA and ST-segment morphology were studied while the coronary artery was occluded for 20 seconds. When data were available, the relationship between EA and blood pressure was analyzed. The clinical and electrocardiographic data were compared with those of the age- and sex-matched controls. During balloon inflation, visible EA was observed in 5 of 306 patients (1.6%) in the last 2 years. EA was limited to PCI in the proximal left anterior descending artery. The ST segment elevated to 10.1 ± 3.2 mm, followed by an alternating QRS complex with a lower ST segment (5.6 ± 1.9 mm; P = .0047) with characteristic ST-segment morphology, which is known as lambda pattern. The mean age of the 5 patients was 68 ± 20 years, and 4(80%). were men. After the release of inflation, the ST-segment level returned rapidly to baseline, followed by normalization of J point. Compared with controls, the maximal elevated ST segment was significantly higher in patients with EA (5.7 ± 2.7 mm; P = .0028). The occlusion of the proximal left anterior descending artery with more severe ischemia seemed to be a prerequisite for developing EA. A higher ST segment was associated with a lower blood pressure and vice versa. A short period of ischemia during PCI may induce visible EA and alternating QRS complexes with a characteristic ST-segment morphology. A higher ST segment was associated with a lower blood pressure and vice versa. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  17. Ratio of systolic blood pressure to left ventricular end-diastolic pressure at the time of primary percutaneous coronary intervention predicts in-hospital mortality in patients with ST-elevation myocardial infarction.

    PubMed

    Sola, Michael; Venkatesh, Kiran; Caughey, Melissa; Rayson, Robert; Dai, Xuming; Stouffer, George A; Yeung, Michael

    2017-09-01

    To determine the ability of simple hemodynamic parameters obtained at the time of cardiac catheterization to predict in-hospital mortality following ST-elevation myocardial infarction (STEMI). Hemodynamic parameters measured at the time of primary percutaneous coronary intervention (PPCI) could potentially identify high-risk patients who would benefit from aggressive hemodynamic support in the Cardiac Catheterization laboratory. This is a retrospective single-center study of 219 consecutive patients with STEMI. Left ventricular end-diastolic pressure (LVEDP), systolic blood pressure (SBP), and aortic diastolic blood pressure were obtained after successful revascularization. The prognostic ability of LVEDP, pulse pressure, and SBP/LVEDP ratio were compared to major mortality risk scores. Patients had a mean age of 60 ±14 years, were predominantly white (73%), male (64%), with anterior wall infarcts in 39%. Comorbidities included diabetes mellitus (27%), heart failure (9%), and chronic kidney disease (7%). In-hospital mortality was 9%. Patients with SBP/LVEDP ≤ 4 had increased risk of in-hospital death (32% vs. 5.3%, P < 0.0001), intra-aortic balloon pump (IABP) usage (51.6% vs. 9.6%, P < 0.0001) and combined endpoint of death or IABP usage (58.1% vs. 13.3%, P < 0.0001) compared to patients with SBP/LVEDP > 4. The area under curve (AUC) for SBP/LVEDP ratio for in-hospital mortality (0.69) was more predictive than LVEDP (0.61, P = 0.04) or pulse pressure (0.55, P = 0.02) but similar to Shock Index (ratio of heart rate to SBP) and Modified Shock Index (ratio of HR to mean arterial pressure). An SBP/LVEDP ratio ≤ 4 identified a group of STEMI patients at high risk of in-hospital death. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  18. Transfer of patients with ST-elevation myocardial infarction for primary percutaneous coronary intervention: a province-wide evaluation of "door-in to door-out" delays at the first hospital.

    PubMed

    Lambert, Laurie J; Brown, Kevin A; Boothroyd, Lucy J; Segal, Eli; Maire, Sébastien; Kouz, Simon; Ross, Dave; Harvey, Richard; Rinfret, Stéphane; Xiao, Yongling; Nasmith, James; Bogaty, Peter

    2014-06-24

    Interhospital transfer of patients with ST-elevation myocardial infarction (STEMI) for primary percutaneous coronary intervention (PPCI) is associated with longer delays to reperfusion, related in part to turnaround ("door in" to "door out," or DIDO) time at the initial hospital. As part of a systematic, province-wide evaluation of STEMI care, we examined DIDO times and associations with patient, hospital, and process-of-care factors. We performed medical chart review for STEMI patients transferred for PPCI during a 6-month period (October 1, 2008, through March 31, 2009) and linked these data to ambulance service databases. Two core laboratory cardiologists reviewed presenting ECGs to identify left bundle-branch block and, in the absence of left bundle-branch block, definite STEMI (according to both cardiologists) or an ambiguous reading. Median DIDO time was 51 minutes (25th to 75th percentile: 35-82 minutes); 14.1% of the 988 patients had a timely DIDO interval (≤30 minutes as recommended by guidelines). The data-to-decision delay was the major contributor to DIDO time. Female sex, more comorbidities, longer symptom duration, arrival by means other than ambulance, arrival at a hospital not exclusively transferring for PPCI, arrival at a center with a low STEMI volume, and an ambiguous ECG were independently associated with longer DIDO time. When turnaround was timely, 70% of patients received timely PPCI (door-to-device time ≤90 minutes) versus 14% if turnaround was not timely (P<0.0001). Benchmark DIDO times for STEMI patients transferred for PPCI were rarely achieved. Interventions aimed at facilitating the transfer decision, particularly in cases of ECGs that are difficult to interpret, are likely to have the best impact on reducing delay to reperfusion. © 2014 American Heart Association, Inc.

  19. Infarct size, left ventricular function, and prognosis in women compared to men after primary percutaneous coronary intervention in ST-segment elevation myocardial infarction: results from an individual patient-level pooled analysis of 10 randomized trials.

    PubMed

    Kosmidou, Ioanna; Redfors, Björn; Selker, Harry P; Thiele, Holger; Patel, Manesh R; Udelson, James E; Magnus Ohman, E; Eitel, Ingo; Granger, Christopher B; Maehara, Akiko; Kirtane, Ajay; Généreux, Philippe; Jenkins, Paul L; Ben-Yehuda, Ori; Mintz, Gary S; Stone, Gregg W

    2017-06-01

    Studies have reported less favourable outcomes in women compared with men after primary percutaneous coronary intervention (PCI) in ST-segment elevation myocardial infarction (STEMI). Whether sex-specific differences in the magnitude or prognostic impact of infarct size or post-infarction cardiac function explain this finding is unknown. We pooled patient-level data from 10 randomized primary PCI trials in which infarct size was measured within 1 month (median 4 days) by either cardiac magnetic resonance imaging or technetium-99m sestamibi single-photon emission computed tomography. We assessed the association between sex, infarct size, and left ventricular ejection fraction (LVEF) and the composite rate of death or heart failure (HF) hospitalization within 1 year. Of 2632 patients with STEMI undergoing primary PCI, 587 (22.3%) were women. Women were older than men and had a longer delay between symptom onset and reperfusion. Infarct size did not significantly differ between women and men, and women had higher LVEF. Nonetheless, women had a higher 1-year rate of death or HF hospitalization compared to men, and while infarct size was a strong independent predictor of 1-year death or HF hospitalization (P < 0.0001), no interaction was present between sex and infarct size or LVEF on the risk of death or HF hospitalization. In this large-scale, individual patient-level pooled analysis of patients with STEMI undergoing primary PCI, women had a higher 1-year rate of death or HF hospitalization compared to men, a finding not explained by sex-specific differences in the magnitude or prognostic impact of infarct size or by differences in post-infarction cardiac function. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  20. Impact of percutaneous mitral valvuloplasty on left ventricular function in patients with mitral stenosis assessed by 3D echocardiography.

    PubMed

    Esteves, William Antonio M; Lodi-Junqueira, Lucas; Soares, Juliana Rodrigues; Sant'Anna Athayde, Guilherme Rafael; Goebel, Gabriela Assunção; Carvalho, Lucas Amorim; Zeng, Xin; Hung, Judy; Tan, Timothy C; Nunes, Maria Carmo Pereira

    2017-12-01

    The status of intrinsic left ventricular (LV) contractility in patients with isolated rheumatic mitral stenosis (MS) has been debated. The acute changes in loading conditions after percutaneous mitral valvuloplasty (PMV) may affect LV performance. We aimed to examine the acute effects of PMV on LV function and identify factors associated with LV ejection fraction (LVEF) changes, and determinants of long-term events following the procedure. One hundred and forty-two patients who underwent PMV for symptomatic rheumatic MS (valve area of 0.99±0.3cm 2 ) were prospectively enrolled. LV volumes and LVEF were measured by three-dimensional (3D) echocardiography. Long-term outcome was a composite endpoint of death, mitral valve (MV) replacement, repeat PMV, new onset of atrial fibrillation, and stroke. The mean age was 42.3±12.1years, and 125 patients were women (88%). After PMV, LVEF increased significantly (51.4 vs 56.5%, p<0.001), primary due to a significant increase in LV end-diastolic volume (65.8mL vs 67.9mL, p=0.002), and resultant increase in the stroke volume (33.9mL vs 39.6mL, p<0.001). Changes in cardiac index and systolic pulmonary artery pressure were associated with LVEF changes after PMV. During a mean follow-up period of 30.8months, 28 adverse clinical events were observed. Postprocedural mitral regurgitation, MV area, and mean gradient were independent predictors of composite endpoints. In patients with rheumatic MS, PMV resulted in a significant improvement in LV end-diastolic volume, stroke volume and consequently increased in LVEF. Changes in cardiac index and systolic pulmonary artery pressure were associated with LVEF changes after PMV. The predictors of long-term adverse events following PMV were post-procedural variables, including mitral regurgitation, valve area, and mean gradient. Copyright © 2017 Elsevier B.V. All rights reserved.

Top