Laparoscopic repair of perforated peptic ulcer-technical tip.
Jayanthi, Naga Venkatesh Gupta
2013-08-01
Increasing number of gastrointestinal emergencies are managed laparoscopically. Laparoscopic repair of a perforated peptic ulcer remains contentious. Fashioning an omental patch is a crucial and an essential part of this repair, whether it is performed open or laparoscopically. This article describes a technique to fashion an adequate omental patch over the perforated peptic ulcer.
Management of nontraumatic corneal perforation with tectonic drape patch and cyanoacrylate glue.
Khalifa, Yousuf M; Bailony, M Rami; Bloomer, Michele M; Killingsworth, Daniel; Jeng, Bennie H
2010-10-01
To report a case of nontraumatic corneal perforation managed with a tectonic drape patch. Interventional case report. A 60-year-old patient with a corneal scar in his left eye likely secondary to herpes simplex virus interstitial keratitis underwent laser peripheral iridotomy for narrow angles. He developed progressive thinning of the cornea overlying the scar that led to a descemetocele and then ultimately a 1.2- × 1.7-mm perforation. Intraoperatively, several attempts were made to seal the perforation with cyanoacrylate glue, but the wound continued to leak. Sterile plastic drape that was on the surgical field was fashioned into a 2-mm-diameter patch, and the peripheral edge of the tectonic drape patch was glued over the perforation, successfully sealing the cornea. One week later, the drape patch was intact without leak, and a penetrating keratoplasty was carried out without complication. Tectonic drape patch technique for nontraumatic corneal perforations in which there is tissue loss is a viable temporizing option when cyanoacrylate glue alone fails and when there is no corneal tissue or amniotic membrane available to close the wound.
Kim, Jangho; Kim, Seung Won; Choi, Seong Jun; Lim, Ki Taek; Lee, Jong Bin; Seonwoo, Hoon; Choung, Pill-Hoon; Park, Keehyun; Cho, Chong-Su; Choung, Yun-Hoon; Chung, Jong Hoon
2011-11-01
Both surgical tympanoplasty and paper patch grafts are frequently procedured to heal tympanic membrane (TM) perforation or chronic otitis media, despite their many disadvantages. In this study, we report a new healing method of TM perforation by using three-dimensional (3D) porous chitosan scaffolds (3D chitosan scaffolds) as an alternative method to surgical treatment or paper patch graft. Various 3D chitosan scaffolds were prepared; and the structural characteristics, mechanical property, in vitro biocompatibility, and healing effects of the 3D chitosan scaffolds as an artificial TM in in vivo animal studies were investigated. A 3D chitosan scaffold of 5 wt.% chitosan concentration showed good proliferation of TM cells in an in vitro study, as well as suitable structural characteristics and mechanical property, as compared with either 1% or 3% chitosan. In in vivo animal studies, 3D chitosan scaffold were able to migrate through the pores and surfaces of TM cells, thus leading to more effective TM regeneration than paper patch technique. Histological observations demonstrated that the regenerated TM with the 3D chitosan scaffold consisted of three (epidermal, connective tissue, and mucosal) layers and were thicker than normal TMs. The 3D chitosan scaffold technique may be an optimal healing method used in lieu of surgical tympanoplasty in certain cases to heal perforated TMs.
Yildiz, Turan; Ilce, Huri Tilla; Ceran, Canan; Ilce, Zekeriya
2014-05-01
Peptic ulcer disease in children is rare. Therefore, the diagnosis can be missed until complications such as perforation or hemorrhage occur. Few reports have investigated the procedures and outcomes of children who have undergone operations for perforated duodenal ulcers. We report our experience with the modified Graham technique for perforated duodenal ulcers in nine children and review the literature. Methods : The records of patients operated on for a perforated duodenal ulcer in the last 8 years in two pediatric surgery centers were evaluated retrospectively. Patient demographics, symptoms, time to admission to hospital, operative findings, and postoperative clinical course were evaluated. Results : Nine children (mean age 13.2 years, range 6-170 years) were included. All patients were admitted in the first six hours after their abdominal pain started. In three patients, there was free air on plain x-rays, while the x-rays were normal in six. All perforations were located on the anterior surface of the first part of the duodenum and repaired with primary suturing and Graham patch omentoplasty. The recovery was uneventful in all patients. In five patients, urea breath tests were performed postoperatively for Helicobacter Pylori, and the results were positive. All patients underwent triple therapy with lansoprazole, amoxicillin, and clarithromycin. The mean follow-up time was 58 (range 3-94) months. Conclusions : Peptic ulcer perforation should be suspected in children who have acute abdominal pain and peritoneal signs, especially when their suffering is intense. The simple patch repair and postoperative triple therapy for Helicobacter Pylori are safe and satisfactory for treating peptic ulcer perforation in children.
Gür, Özer Erdem; Ensari, Nuray; Öztürk, Mehmet Türker; Boztepe, Osman Fatih; Gün, Taylan; Selçuk, Ömer Tarık; Renda, Levent
2016-10-01
(1) To evaluate the effects of a platelet-rich fibrin (PRF) membrane in the repair of traumatic tympanic membrane (TM) perforations; and (2) to compare the use of a PRF membrane with the paper patch technique with regard to recovery rates, healing time, and correction of the mean air-bone gap. A randomized, prospective analysis was performed for 60 patients who were treated for traumatic TM perforations using one of the two methods. Closure rate, speed of healing, and hearing gain were compared between the PRF (Group 1) and paper patch (Group 2) groups. Closure was obtained in 28 (93%) perforations in Group 1 and 25 (83%) perforations in Group 2 (p > 0.05). On day 10, full closure of the TM was observed in 24 (80%) patients in Group 1 and 16 (53%) patients in Group 2 (p < 0.05). The improvement in the mean air-bone gap was 14.1 dB in Group 1 and 12.4 dB in Group 2 on post-operative day 45 (p < 0.05). In comparison with the paper patch method, PRF, a new method, provided more rapid healing with more successful audiological results, and with no requirement for a second procedure.
Huang, Peng; Zhang, Shujun; Gong, Xinhong; Wang, Xuesong; Lou, Zi-Han
2017-08-03
In the last decade, there has been an increasing use of biomaterial patches in the regeneration of traumatic tympanic membrane perforations. The major advantages of biomaterial patches are to provisionally restore the physiological function of the middle ear, thereby immediately improving ear symptoms, and act as a scaffold for epithelium migration. However, whether there are additional biological effects on eardrum regeneration is unclear for biological material patching in the clinic. This study evaluated the healing response for different repair patterns in human traumatic tympanic membrane perforations by endoscopic observation. In total, 114 patients with traumatic tympanic membrane perforations were allocated sequentially to two groups: the spontaneous healing group (n=57) and Gelfoam patch-treated group (n=57). The closure rate, closure time, and rate of otorrhea were compared between the groups at 3 months. Ultimately, 107 patients were analyzed in the two groups (52 patients in the spontaneous healing group vs. 55 patients in the Gelfoam patch-treated group). The overall closure rate at the end of the 3 month follow-up period was 90.4% in the spontaneous healing group and 94.5% in the Gelfoam patch-treated group; the difference was not statistically significant (p>0.05). However, the total average closure time was significantly different between the two groups (26.8±9.1 days in the spontaneous healing group vs. 14.7±9.1 days in the Gelfoam patch-treated group, p<0.01). In addition, the closure rate was not significantly different between the spontaneous healing group and Gelfoam patch-treated group regardless of the perforation size. The closure time in the Gelfoam patch-treated group was significantly shorter than that in the spontaneous healing group regardless of the perforation size (small perforations: 7.1±1.6 days vs. 12.6±3.9, medium-sized perforations: 13.3±2.2 days vs. 21.8±4.2 days, and large perforations: 21.2±4.7 days vs. 38.4±5.7 days; p<0.01). In the regeneration of traumatic tympanic membrane perforations, Gelfoam patching not only plays a scaffolding role for epithelial migration, it also promotes edema and hyperplasia of granulation tissue at the edges of the perforation and accelerates eardrum healing. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Maghsoudi, Hemmat; Ghaffari, Alireza
2011-01-01
Peptic ulcer perforations are a common emergency, but available literature is silent on the exact definition, incidence, management, and complications of peritonitis due to omental patch leakage. Retrospective data were collected on 422 patients who underwent omental patch repair of perforated peptic ulcer between March 20, 1999 and March 20, 2006. The definitive diagnosis of perforated peptic ulcer and omental patch leakage was obtained at surgery. Seventeen (4%) patients experienced generalized peritonitis due to omental patch leakage. Mean age was 60.6 years. Mortality rate was 29.4%, and the mean hospital stay was 23.6 days. Delay in surgical approach, shock on admission, and age were all significantly associated with increased mortality. Peritonitis due to omental patch leakage can result in significant morbidity and mortality. The most common causes of omental patch leakage and operative procedures were unknown and reinsertion of omentum, respectively. Factors such as shock on admission or delayed surgery, have significantly contributed to fatal outcomes and need careful attention.
Gupta, Vaibhav; Zani, Augusto; Jackson, Paul; Singh, Shailinder
2015-06-08
A 7-year-old boy presented in septic shock secondary to appendicitis with generalised peritonitis. Following crystalloid resuscitation, he underwent surgery. Faecopurulent contamination and free air were found. This was secondary to a perforated and gangrenous appendix, multiple large and small bowel segments with perforations, patches of necrosis, interspersed with healthy bowel and segments of questionable viability. There was also a perforated duodenal ulcer. Necrotic segments were resected using a 'clip-and-drop' technique to shorten operative duration and guide resection to preserve bowel length. After six laparotomies and multiple bowel resections, the child was discharged home with an ileostomy that was subsequently reversed. He is currently on a normal diet and pursuing all activities appropriate for his age. Perforated appendicitis can be associated with widespread bowel necrosis and multiple perforations. A conservative damage limitation approach using the 'clip-and-drop' technique and relook laparotomies is useful in the management of extensive bowel necrosis in children. 2015 BMJ Publishing Group Ltd.
Abbasi, Hamid Reza; Bolandparvaz, Shahram; Yarmohammadi, Hooman; Geramizadeh, Bita; Tanideh, Nader; Paydar, Shahram; Hosseini, Seyed Vahid
2006-10-01
Primary repair of traumatic colonic perforation is progressively gaining acceptance as the best method of management. However, when delayed, the risk of infection-related complications may increase. Here, we present a new method of repairing colon perforation in the presence of peritonitis. Acute colon injury was simulated in 22 German shepherd dogs. The dogs were randomly divided into two groups of 11 and after 24 hours they were operated on. The perforations were repaired by subserosal suture technique. In the first group (group A), ileal patch was used. In the other group (group B), the colon was closed by debridement and anastomosis. After 6 weeks, the repairs were assessed on the basis of survival, gross and histological assessments. Nine (82%) dogs in group A and six (56%) in group B survived. Ileal patch utilization significantly decreased the mortality rate (p < 0.05). The cause of death in two group A dogs and five group B dogs was peritonitis and intra-abdominal abscess formation. None of the surviving dogs showed evidence of anastomotic leakage or breakdown. Small bowel patch used in primary repair of colon injury in the presence of peritonitis may decrease the risk of postoperative infection-related complications and the mortality rate.
Maghsoudi, Hemmat; Ghaffari, Alireza
2011-01-01
Background/Aim: Peptic ulcer perforations are a common emergency, but available literature is silent on the exact definition, incidence, management, and complications of peritonitis due to omental patch leakage. Patients and Methods: Retrospective data were collected on 422 patients who underwent omental patch repair of perforated peptic ulcer between March 20, 1999 and March 20, 2006. The definitive diagnosis of perforated peptic ulcer and omental patch leakage was obtained at surgery. Results: Seventeen (4%) patients experienced generalized peritonitis due to omental patch leakage. Mean age was 60.6 years. Mortality rate was 29.4%, and the mean hospital stay was 23.6 days. Delay in surgical approach, shock on admission, and age were all significantly associated with increased mortality. Conclusions: Peritonitis due to omental patch leakage can result in significant morbidity and mortality. The most common causes of omental patch leakage and operative procedures were unknown and reinsertion of omentum, respectively. Factors such as shock on admission or delayed surgery, have significantly contributed to fatal outcomes and need careful attention. PMID:21372350
Samarawickrama, Chameen; Samanta, Ayan; Liszka, Aneta; Fagerholm, Per; Buznyk, Oleksiy; Griffith, May; Allan, Bruce
2018-05-01
To describe the use of collagen-based alternatives to cyanoacrylate glue for the sealing of acute corneal perforations. A collagen analog comprising a collagen-like peptide conjugated to polyethylene glycol (CLP-PEG) and its chemical crosslinker were tested for biocompatibility. These CLP-PEG hydrogels, which are designed to act as a framework for corneal tissue regeneration, were then tested as potential fillers in ex vivo human corneas with surgically created full-thickness perforations. Bursting pressures were measured in each of 3 methods (n = 10 for each condition) of applying a seal: 1) cyanoacrylate glue with a polyethylene patch applied ab externo (gold standard); 2) a 100-μm thick collagen hydrogel patch applied ab interno, and 3) the same collagen hydrogel patch applied ab interno supplemented with CLP-PEG hydrogel molded in situ to fill the remaining corneal stromal defect. Cyanoacrylate gluing achieved a mean bursting pressure of 325.9 mm Hg, significantly higher than the ab interno patch alone (46.3 mm Hg) and the ab interno patch with the CLP-PEG filler (86.6 mm Hg). All experimental perforations were sealed effectively using 100 μm hydrogel sheets as an ab interno patch, whereas conventional ab externo patching with cyanoacrylate glue failed to provide a seal in 30% (3/10) cases. An ab interno patch system using CLP-PEG hydrogels designed to promote corneal tissue regeneration may be a viable alternative to conventional cyanoacrylate glue patching for the treatment of corneal perforation. Further experimentation and material refinement is required in advance of clinical trials.
Perforated gastric ulcer--reappraisal of surgical options.
Madiba, T E; Nair, R; Mulaudzi, T V; Thomson, S R
2005-08-01
The available operative procedures for perforated gastric ulcer are gastrectomy, ulcer excision and omental patch closure. This study analysed the outcome of these operative options in a single institution. Seventy-two patients (mean age 43 years, 62 males) with perforated gastric ulcers were managed by laparotomy. There were 34 lesser curve (incisural) and 38 antral ulcers. Partial gastrectomy was performed in 27 patients, ulcer excision in 27 and simple patch closure in 18. Two ulcers were malignant. The mortality rate was 18% (26% for gastrectomy, 19% for ulcer excision and 5% for patch closure). Shock on admission (p = 0.006) and Candida (p = 0.020) in the histological specimen were predictive of poor outcome. Hospital stay was similar in the 3 groups. Omental patch closure and ulcer excision are as effective as gastrectomy in the management of perforated gastric ulcer and merit consideration as first-line therapy in technically applicable cases.
Perforator-based island flap with a peripheral muscle patch for coverage of sacral sores.
Chang, Jung Woo; Lee, Jang Hyun; Choi, Matthew Seung Suk
2016-06-01
Despite numerous therapeutic advances, the treatment of pressure sores remains a challenge. The increased use of perforator flaps enables surgeons to minimize donor-site morbidity by sparing the underlying muscle. In the presence of focal deep spaces, however, the inclusion of muscle would be beneficial. The goal of this study was to introduce a method for including a muscle patch at the periphery of a perforator-based island flap for coverage of sacral pressure sores. Between March 2010 and February 2015, 26 patients with stage IV sacral sores underwent perforator-based island flap reconstruction with a peripheral muscle patch. Patient characteristics, including sex, age, defect size, and postoperative complications, were recorded. All flaps survived without major complications. No flap necrosis was noted. The present study shows that a muscle patch incorporated into the periphery of a perforator-based flap can be transferred safely. This can be a good surgical option in cases where infection control or more volume is needed. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Natural orifice transluminal endoscopic surgery for patients with perforated peptic ulcer.
Bonin, Eduardo A; Moran, Erica; Gostout, Christopher J; McConico, Andrea L; Zielinski, Martin; Bingener, Juliane
2012-06-01
Perforation accounts for 70% of deaths attributed to peptic ulcers. Laparoscopic repair is effective but infrequently used. Our aim was to assess how many patients with perforated peptic ulcer could be candidates for a transluminal endoscopic omental patch closure. This retrospective study reviewed patients with perforated peptic ulcer from 2005 to 2010. Demographics, ulcer characteristics, operative procedure, and outcomes were recorded. Candidates for endoscopic transluminal repair were defined as those having undergone omental patch closure of an ulcer of appropriate size and no contraindications to laparoscopy or endoscopy. In the retrospective review, a total of 104 patients were identified; 62% female, mean age = 68 years, mean ASA of 3, and 63% medication-related ulcers. Fifty-nine (63%) had an omental patch (80% open), and 35 (37%) had other procedures. Ten patients had nonoperative management. Thirty-day mortality was 14% and 1 year mortality was 35%. Forty-nine patients (52%) were considered potential candidates for transluminal repair. Sixty-three percent of our patients sustained a medication-related perforation with 1 year mortality of 35%. The majority of patients were treated using open omental patch repair. Transluminal endoscopic repair may provide an additional situation for a minimally invasive approach for a number of these patients.
Wendling, Mark R; Linn, John G; Keplinger, Kara M; Mikami, Dean J; Perry, Kyle A; Melvin, W Scott; Needleman, Bradley J
2013-02-01
Marginal ulcer formation remains a significant complication of Roux-en-Y gastric bypass (RYGB). Up to 1 % of all RYGB patients will develop free perforation of a marginal ulcer. Classically, this complication has required anastomotic revision; however, this approach is associated with significant morbidity. Several small series have suggested that omental patch repair may be effective. The aim of this study was to examine the management of perforated marginal ulcers following RYGB. All patients who underwent operative intervention for perforated ulcers between 2003 and 2011 were reviewed. Those with a history of RYGB with perforation of a marginal ulcer were included in the analysis. Data collected included operative approach, operative time, blood loss, length of hospital stay, complications, smoking history, and steroid or NSAID use. From January 2003 to December 2011, a total of 1,760 patients underwent RYGB at our institution. Eighteen (0.85 %) developed perforation of a marginal ulcer. Three patients' original procedure was performed at another institution. Eight patients (44 %) had at least one risk factor for ulcer formation. Treatment included omental patch repair (laparoscopic, n = 7; open, n = 9) or anastomotic revision (n = 2). Compared to anastomotic revision, omental patch repair had shorter OR time (101 ± 57 vs. 138 ± 2 min), decreased estimated blood loss (70 ± 72 vs. 250 ± 71 mL), and shorter total length of stay (5.6 ± 1.4 vs. 11.0 ± 5.7 days). Perforated marginal ulcer represents a significant complication of RYGB. Patients should be educated to reduce risk factors for perforation, as prolonged proton pump inhibitor therapy may not prevent this complication in a patient with even just one risk factor. In our sample population we found laparoscopic or open omental patch repair to be a safe and effective treatment for this condition and it was associated with decreased operative time, blood loss, and length of stay.
Laparoscopic management of duodenal ulcer perforation: is it advantageous?
Palanivelu, C; Jani, Kalpesh; Senthilnathan, P
2007-01-01
Surgery is the mainstay of treatment of patients with peptic duodenal perforation. With the advent of minimal access techniques, laparoscopy is being used for the treatment of this condition. Retrospective analysis of 120 consecutive patients (mean age 44.5 years; 111 men) with duodenal ulcer perforation who had undergone laparoscopic surgery. 87 patients had history of tobacco consumption, 12 were chronic NSAID users, 72 had Helicobacter pylori infection and 36 had a co-morbid condition. The mean time to surgery from onset of symptoms was 28.4 hours. The median operating time was 46 minutes. All patients underwent laparoscopic closure of the perforation with Graham's patch omentopexy; 12 patients underwent additional definitive ulcer surgery. The morbidity rate was 7.5%; no patient needed conversion to open surgery or died. The mean postoperative hospital stay was 5.8 days. Results of laparoscopic management of perforated peptic ulcer are encouraging, with no conversion to open surgery, low morbidity and no mortality.
Perforated peptic ulcer (PPU) in pregnancy during Ramadan fasting.
Gali, B M; Ibrahim, A G; Chama, C M; Mshelia, H B; Abubakar, A; Takai, I U; Takie, U; Bwala, S
2011-01-01
Perforated Peptic Ulcer (PPU) is extremely rare in pregnancy. We report a case of perforated peptic ulcer in pregnancy during Ramadan fasting. The patient is a 16 years old primigravida who presented with features of peritonitis at 28weeks of gestation while fasting during Ramadan. Ultrasound scan reported a singleton live fetus at 28 weeks gestation. At laparotomy via upper midline incision; a 1 cm roundish perforation located on the duodenum anteriorly was found with about a litre of gastric juice mixed with blood and food particles in the peritoneal cavity. The perforation was close transversely with omental patch (Modified Graham's patch) and peritoneal lavage done with warm saline. She had a preterm delivery of a 1 kg baby 3 days post-operatively by a spontaneous vaginal delivery, but the baby died 3 days later. Perforated Peptic Ulcer(PPU) though rare in pregnancy can occur and fasting can be a risk factor.
Mijangos-Vázquez, Roberto; García-Montes, Antonio J; Soto-López, Elena M; Guarner-Lans, Verónica; Zabal, Carlos
2018-05-01
The objective of this study was to demonstrate the safety and feasibility of using the new Cardia Ultrasept II™ device with interposed Goretex patch referring to the perforation of polyvinyl alcohol membrane. Great advances have been made in the development of devices for closure of atrial septal defect. The Cardia Ultrasept II™ with interposed Goretex patch is the modified last generation of Cardia devices, having the advantage of a super-low profile within the atria and an integral locking delivery-retrieval mechanism that ensures safe deployment. In addition, with the interposition of the Goretex, it has been possible to abolish perforation of Ivalon's membrane as a complication.Methods and resultsPatients with ostium secundum atrial septal defect with surrounding rims with a minimum length of 5 mm and who underwent atrial septal defect closure with the new Ultrasept II™ with Goretex patch were included from two paediatric cardiac centres. Primary end point was to determine perforation of the Goretex membrane at follow-up; secondary end point included right ventricular diastolic diameter. In total, 30 patients underwent atrial septal defect closure at a median age of 6 (1-29) years. At follow-up for 6 (range, 1-15) months, freedom from perforations was 100%. A continuous decrease in right ventricular diastolic diameter was found with an initial median of 30 (25-49) mm and after catheterisation of 27.5 (18-33) mm, p=0.01, and Z-score of 2.6 (1.7-3.6) versus 1.9 (1-2.9) after procedure, p=0.01. The new modified generation of the Ultrasept II™ device with interposed Goretex patch is a good alternative to achieve atrial septal defect closure safely and feasibly with no membrane perforation at follow-up.
[Rare complication following oesophagectomy: early peptic ulcer perforation of the tubal stomach].
Géczi, Tibor; Paszt, Attila; Simonka, Zsolt; Furák, József; Lázár, György
2011-10-01
We report the case of a 45-year-old male patient who developed an acute peptic ulcer perforation of the tubal stomach on the second postoperative day after oesophagectomy. The patient underwent emergency surgery (perforation was closed with a Graham patch) followed by treatment in intensive care, and was finally discharged on the 19th postoperative day. Gastric pull-up is a surgical technique that is widely used to re-establish the continuity of the gastrointestinal tract after oesophagectomy. Various early and late complications of reconstruction with the tubal stomach are well-known, such as gastric necrosis, gastritis, gastric ulcer, as well as benign and malignant tumors. The precise etiology of gastric tube ulceration is not known yet, however, it can develop not only in the late, but also in the early postoperative period, as well.
Nuhu, A; Madziga, A G; Gali, B M
2009-01-01
Effective medical management of peptic ulcer disease (PUD) has reduced the incidence of gastric outlet obstruction (GOO) as a complication, but perforation especially in the elderly remains unchanged and is in fact on the increase. There is a changing trend in emergency surgery for perforated duodenal ulcer (PDU) from definitive anti ulcer surgery to simple closure followed by Helicobacter pylori eradication. To present our experience in managing PDU with simple closure followed by Helicobacter pylori eradication. This was a chart review of patients managed for PDU over a nine year period (Jan 1999 to Dec 2007) using information obtained from ward admission registers, theatre operation registers, and patients case files from the medical records department. The patients biodata, clinical, and operative findings as well as treatment outcome were extracted for analysis. Of 55 patients eligible for analysis, 44 (80%) were males and 11(20%) females (M to F, 4:1). Their ages ranged between 18 and 65 years with a mean(SD) of 39.9 (13.5) years. Most of the patients, 34 (61.8%), were below 40 years of age and majority 39(71.0%) had a history suggestive of chronic peptic ulcer disease. Twenty six (47.3%) patients presented within 24 hours of perforation, while nine (16.4%) presented more than 72 hours afterwards. The latter group accounted for most, five(55.6%), of the mortality. All the perforations were anterior pyloroduodenal and all except one had simple closure with omental patch followed by a course of a proton pump inhibitor and Helicobacter pylori eradication therapy. Simple closure with omental patch followed by Helicobacter pylori eradication is effective in managing PDU with low morbidity and mortality despite patients late presentation in our center. This technique is recommended in place of a definitive ulcer surgery.
Iatrogenic Aortic Valve Perforation after Ventricular Septal Defect Repair
Ren, Chonglei; Wang, Mingyan; Wang, Yao; Gao, Changqing
2017-01-01
Iatrogenic aortic valve (AV) perforation during non-aortic cardiac operations is a rare complication. The suture-related inadvertent injury to an AV leaflet can produce leaflet perforation with aortic regurgitation after ventricular septal defect repair (VSDR). We report three consecutive patients who had iatrogenic aortic leaflet perforation during VSDR in other hospitals and referred to our hospital for reoperation. In all three cases, the perforated AV leaflets were preserved and repaired by autologous pericardial patch or direct local closure. PMID:29057770
Marginal ulcer perforation: a single center experience.
Natarajan, S K; Chua, D; Anbalakan, K; Shelat, V G
2017-10-01
Marginal ulcer (MU) is defined as ulcer on the jejunal side of the gastrojejunostomy (GJ) anastomosis. Most MUs are managed medically but those with complications like bleeding or perforation require intervention. It is recommended that GJ anastomosis be revised in patients with MU perforation (MUP). The aim of this case series is to study the clinical presentation and management of MUP. Three hundred and thirty-two patients who underwent emergency surgery for perforated peptic ulcer at a single center were studied over a period of 5 years. Nine patients (2.7 %) presented with MUP. GJ was previously done for either complicated peptic ulcer (n = 4) or for suspected gastric malignancy (n = 5). Two patients had previously completed H. pylori therapy. None of the patients presented with septic shock. MU was on the jejunal side of GJ in all patients. The median MUP size was 10 mm. Four patients (44.4 %) had omental patch repair, three (33.3 %) had primary closure, and one each had revision of GJ and jejunal serosal patch repair. There were no leaks, intra-abdominal abscess or reoperation and no malignancies. MUP patients do not present with septic shock. Omental patch repair or primary closure is sufficient enough. Revision of Billroth-II-GJ into Roux-en-Y-GJ is not mandatory.
Lee, Daniel Jin Keat; Ye, MaDong; Sun, Keith Haozhe; Shelat, Vishalkumar G; Koura, Aaryan
2016-01-01
Introduction. The aim of this study was to compare the outcomes between laparoscopic and open omental patch repair (LOPR versus OR) in patients with similar presentation of perforated peptic ulcer (PPU). The secondary aim was to evaluate the outcomes according to the severity of peritonitis. Methods. All patients who underwent omental patch repair at two university-affiliated institutes between January 2010 and December 2014 were reviewed. Matched cohort between LOPR and OR groups was achieved by only including patients that had ulcer perforation <2 cm in size and symptoms occurring <48 hours. Outcome measures were defined in accordance with length of stay (LOS), postoperative complications, and mortality. Results. 148 patients met the predefined inclusion criteria with LOPR performed in 40 patients. Outcome measures consistently support laparoscopic approach but only length of hospital stay (LOS) achieved statistical significance (LOPR 4 days versus OR 5 days, p < 0.01). In a subgroup analysis of patients with MPI score >21, LOPR is also shown to benefit, particularly resulting in significant shorter LOS (4 days versus 11 days, p < 0.01). Conclusion. LOPR offers improved short-term outcomes in patients who present within 48 hours and with perforation size <2 cm. LOPR also proved to be more beneficial in high MPI cases.
Sun, Keith Haozhe; Koura, Aaryan
2016-01-01
Introduction. The aim of this study was to compare the outcomes between laparoscopic and open omental patch repair (LOPR versus OR) in patients with similar presentation of perforated peptic ulcer (PPU). The secondary aim was to evaluate the outcomes according to the severity of peritonitis. Methods. All patients who underwent omental patch repair at two university-affiliated institutes between January 2010 and December 2014 were reviewed. Matched cohort between LOPR and OR groups was achieved by only including patients that had ulcer perforation <2 cm in size and symptoms occurring <48 hours. Outcome measures were defined in accordance with length of stay (LOS), postoperative complications, and mortality. Results. 148 patients met the predefined inclusion criteria with LOPR performed in 40 patients. Outcome measures consistently support laparoscopic approach but only length of hospital stay (LOS) achieved statistical significance (LOPR 4 days versus OR 5 days, p < 0.01). In a subgroup analysis of patients with MPI score >21, LOPR is also shown to benefit, particularly resulting in significant shorter LOS (4 days versus 11 days, p < 0.01). Conclusion. LOPR offers improved short-term outcomes in patients who present within 48 hours and with perforation size <2 cm. LOPR also proved to be more beneficial in high MPI cases. PMID:27722200
Laparoscopic repair of perforated peptic ulcer: patch versus simple closure.
Abd Ellatif, M E; Salama, A F; Elezaby, A F; El-Kaffas, H F; Hassan, A; Magdy, A; Abdallah, E; El-Morsy, G
2013-01-01
Laparoscopic correction of perforated peptic ulcer (PPU) has become an accepted way of management. Patch omentoplasty stayed for decades the main method of repair. The goal of the present study was to evaluate whether laparoscopic simple repair of PPU is as safe as patch omentoplasty. Since June 2005, 179 consecutive patients of PPU were treated by laparoscopic repair at our centers. We conducted a retrospective chart review in December 2012. Group I (patch group) included patients who were treated with standard patch omentoplasty. Group II (non-patch group) included patients who received simple repair without patch. From June 2007 to Dec. 2012, 179 consecutive patients of PPU who were treated by laparoscopic repair at our centers were enrolled in this multi-center retrospective study. 108 patients belong to patch group. While 71 patients were treated with laparoscopic simple repair. Operative time was significantly shorter in group II (non patch) (p = 0.01). No patient was converted to laparotomy. There was no difference in age, gender, ASA score, surgical risk (Boey's) score, and incidence of co-morbidities. Both groups were comparable in terms of hospital stay, time to resume oral intake, postoperative complications and surgical outcomes. Laparoscopic simple repair of PPU is a safe procedure compared with the traditional patch omentoplasty in presence of certain selection criteria. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.
Lee, Jun Seok; Lee, Sun Kyu; Shin, Il Ho; Yeo, Seung Geun; Park, Moon Suh; Byun, Jae Yong
2014-01-01
Vestibular evoked myogenic potential (VEMP) function results can vary between individuals with different middle ear conditions. Therefore, by analyzing VEMP results after paper patching, we can predict the condition of the middle ear in chronic otitis media (COM) patients. VEMP responses decrease with impairment of sound transmission, such as in conductive hearing loss (CHL). COM with tympanic membrane (TM) perforation is a common disorder that causes various degrees of CHL. The aim of this study was to evaluate and clarify the VEMP responses in patients with COM with different middle ear pathology. This study included 50 patients with unilateral COM with TM perforation. Initial pure-tone audiometry (PTA) and VEMP responses were recorded. After paper patching, PTA and VEMP were re-performed. Each VEMP response was compared with those of the healthy controls. Moreover, VEMP responses between pre- and post-paper patching were compared. There was a positive correlation between normalizing of VEMP parameters, such as p13 and VEMP asymmetry ratio (VAR), and reduction of air-bone gap in patients with COM after paper patching. The VEMP response in patients with COM with intact ossicle and clean mucosa was more normalized compared with those in patients with COM with different middle ear conditions.
Flexible CO2 laser and submucosal gel injection for safe endoluminal resection in the intestines.
Au, Joyce T; Mittra, Arjun; Wong, Joyce; Carpenter, Susanne; Carson, Joshua; Haddad, Dana; Monette, Sebastien; Ezell, Paula; Patel, Snehal; Fong, Yuman
2012-01-01
The CO(2) laser's unique wavelength of 10.6 μm has the advantage of being readily absorbed by water but historically limited it to line-of-sight procedures. Through recent technological advances, a flexible CO(2) laser fiber has been developed and holds promise for endoluminal surgery. We examined whether this laser, along with injection of a water-based gel in the submucosal space, will allow safe dissection of the intestines and enhance the potential of this tool for minimally invasive surgery. Using an ex vivo model with porcine intestines, spot ablation was performed with the flexible CO(2) laser at different power settings until transmural perforation. Additionally, excisions of mucosal patches were performed by submucosal dissection with and without submucosal injection of a water-based gel. With spot ablation at 5 W, none of the specimens was perforated by 5 min, which was the maximum recorded time. The time to perforation was significantly shorter with increased laser power, and gel pretreatment protected the intestines against spot ablation, increasing the time to perforation from 6 to 37 s at 10 W and from 1 to 7 s at 15 W. During excision of mucosal patches, 56 and 83% of untreated intestines perforated at 5 and 10 W, respectively. Gel pretreatment prior to excision protected all intestines against perforation. These specimens were verified to be intact by inflation with air to over 100 mmHg. Furthermore, excision of the mucosal patch was complete in gel-pretreated specimens, whereas 22% of untreated specimens had residual islands of mucosa after excision. The flexible CO(2) laser holds promise as a precise dissection and cutting tool for endoluminal surgery of the intestines. Pretreatment with a submucosal injection of a water-based gel protects the intestines from perforation during ablation and mucosal dissection.
Flexible CO2 laser and submucosal gel injection for safe endoluminal resection in the intestines
Au, Joyce T.; Mittra, Arjun; Wong, Joyce; Carpenter, Susanne; Carson, Joshua; Haddad, Dana; Monette, Sebastien; Ezell, Paula; Patel, Snehal
2012-01-01
Background The CO2 laser’s unique wavelength of 10.6 µm has the advantage of being readily absorbed by water but historically limited it to line-of-sight procedures. Through recent technological advances, a flexible CO2 laser fiber has been developed and holds promise for endoluminal surgery. We examined whether this laser, along with injection of a water-based gel in the submucosal space, will allow safe dissection of the intestines and enhance the potential of this tool for minimally invasive surgery. Methods Using an ex vivo model with porcine intestines, spot ablation was performed with the flexible CO2 laser at different power settings until transmural perforation. Additionally, excisions of mucosal patches were performed by submucosal dissection with and without submucosal injection of a water-based gel. Results With spot ablation at 5 W, none of the specimens was perforated by 5 min, which was the maximum recorded time. The time to perforation was significantly shorter with increased laser power, and gel pretreatment protected the intestines against spot ablation, increasing the time to perforation from 6 to 37 s at 10 W and from 1 to 7 s at 15 W. During excision of mucosal patches, 56 and 83% of untreated intestines perforated at 5 and 10 W, respectively. Gel pretreatment prior to excision protected all intestines against perforation. These specimens were verified to be intact by inflation with air to over 100 mmHg. Furthermore, excision of the mucosal patch was complete in gel-pretreated specimens, whereas 22% of untreated specimens had residual islands of mucosa after excision. Conclusion The flexible CO2 laser holds promise as a precise dissection and cutting tool for endoluminal surgery of the intestines. Pretreatment with a submucosal injection of a water-based gel protects the intestines from perforation during ablation and mucosal dissection. PMID:21898027
Wong, Carol W Y; Chung, Patrick H Y; Tam, Paul K H; Wong, Kenneth K Y
2015-12-01
Perforated peptic ulcer (PPU) is a relatively uncommon condition in children. We aim to evaluate and compare the outcomes of laparoscopic omental patch repair versus open repair for PPU in pediatric patients. Children who underwent omental patch repair for PPU from 2004 to 2014 in our hospital were reviewed retrospectively. Patient demographics, perioperative as well as intraoperative details and surgical outcomes, were analyzed. Thirteen patients were identified, and all presented with abdominal pain. The median age of the study group was 14.9years (range 6.3 to 18.4years). Radiological evidence of pneumoperitoneum on erect chest x-ray (CXR) was found only in five patients (38.5%). None of the patients had a known history of peptic ulcer disease. Diagnosis other than PPU was made in five patients preoperatively. Laparoscopic repair was attempted in eight patients with one of them requiring conversion. There was no significant difference in patient demographics when compared with the open repair group. The perforation site was in the duodenum in 11 patients and in the antrum in two patients. The mean size of perforation was larger in the open repair group (p=0.005). Although the operating time was longer in the laparoscopic group (p=0.51), the length of hospital stay was significantly shorter (p=0.048). Only two patient diseases were Helicobacter pylori related. Clinical features of perforated peptic ulcer in children are different from adults. Risk factors are less frequently identified. Laparoscopic omental patch repair is a feasible surgical option and is associated with satisfactory outcomes in pediatric practice. Copyright © 2015 Elsevier Inc. All rights reserved.
Kalaiselvan, Ramya; Exarchos, Georgios; Hamza, Numan; Ammori, Basil J
2012-01-01
Laparoscopic Roux-en-Y gastric bypass (RYGB) is a well-established procedure to treat morbid obesity. Gastrojejunal anastomotic (GJA) ulcers can develop after surgery with subsequent perforation. Our aim was to evaluate the incidence, presentation and outcome of management of perforated GJA ulcer disease after laparoscopic RYGB. The database of all patients at the senior author's bariatric institutions was retrospectively reviewed. The results are presented as mean (range). From April 2002 to April 2010, 1213 patients underwent laparoscopic RYGB, which included 1184 primary and 29 revision procedures. The operative mortality was .15%. Ten patients developed perforated GJA ulcers (.82%) at a mean of 13.5 (6-19) months. The patients who presented to bariatric surgeons (n = 5) were treated with laparoscopic closure and an omental patch, and those who presented to nonbariatric surgeons (n = 5) were treated with laparotomy. The morbidity and mortality rate was 30% and 10%, respectively, and the mean postoperative hospital stay for the survivors was 14 (5-44) days. Perforated GJA ulcers can develop in 1 of 120 patients after laparoscopic RYGB and can be effectively managed by laparoscopic repair with an omental patch, if expertise is available. Copyright © 2012 American Society for Metabolic and Bariatric Surgery. Published by Elsevier Inc. All rights reserved.
Dodiyi-Manuel, A; Wichendu, P N; Enebeli, V C
2015-01-01
Perforations of the stomach and duodenum are common complications of peptic ulcer disease (PUD), abuse of non steroidal anti inflammatory drugs (NSAIDS) and gastric cancer. Being a life threatening complication of PUD, it needs special attention with prompt resuscitation and appropriate surgical management if morbidity and mortality are to be avoided. To determine the pattern and management outcome of perforated peptic ulcer disease PUD as seen in University of Port Harcourt Teaching Hospital (UPTH), Port Harcourt, Rivers State, Nigeria). All the patients with perforated PUD that were managed at UPTH between January 2006 and December 2014 were studied. Relevant data were extracted from the case notes and analysed using the Statistical Package for Social Sciences (SPSS) version 17. Thirty six patients with perforated PUD were evaluated consisting of 28 males and 8 females with a male to female ratio of 3.5:1. Their ages ranged from 24 to 65 years with a mean of 42.1± 12.3 years and the peak age was at the third decade. After adequate resuscitation, all the patients had exploratory laparotomy. In 26 (72.2%) patients, the perforation was in the duodenum while in 10 (27.8%), it was in the stomach. Thirty two (88.9%) patients had Graham's omental patch repair of the perforation while simple closure only was done in 4 (11.1%) patients. Surgical site infection was the commonest post operative complication which was seen in 7 (19.4%) patients while 4 patients died giving a mortality rate of 11.1%. Perforated peptic ulcer predominantly affected young males and Graham's omental patch followed by Helicobacter pylori eradication was an effective treatment modality.
Endoscope-assisted laparoscopic repair of perforated peptic ulcers.
Lee, Kun-Hua; Chang, Hung-Chi; Lo, Chong-Jeh
2004-04-01
Laparoscopic repairs for perforated peptic ulcer (PPU) are likely to fail in patients with shock, gastric outlet obstruction, or large perforations. This prospective study was performed to evaluate a revised approach of laparoscopic repair with endoscopic assistance to treat these patients. Between April 2001 and February 2002, 30 consecutive patients with PPU were enrolled in this study. The mean age was 43.1 +/- 12.2 years. Male to female ratio was 27:2. One patient was excluded from laparoscopic repair due to a gastric outlet obstruction. The other 29 patients were managed according to a protocol of preoperative upper endoscopy and laparoscopic intracorporeal suture repair with an omental patch. The average operative time was 58.1 +/- 13.5 minutes (range, 36-96 min). The average diameter of perforation was 4.2 +/- 2.0 mm (range, 1-12 mm). The average time to resume oral fluids was 3.2 +/- 0.8 days (range, 2-8 days). The average hospital stay was 4.7 +/- 1.1 days (range, 3-10 days). There was no leakage or mortality. Most patients did not receive parenteral analgesics postoperatively. We conclude that endoscope-assisted laparoscopic repair for PPU is safe and effective. This revised technique allows surgeons to exclude patients who are likely to fail the laparoscopic repair.
Dietz, Shelby; Husch, Andreas; Harris-Warrick, Ronald M.
2012-01-01
Whole cell recordings (WCRs) are frequently used to study neuronal properties, but may be problematic when studying neuromodulatory responses, due to dialysis of the cell's cytoplasm. Perforated patch recordings (PPR) avoid cellular dialysis and might reveal additional modulatory effects that are lost during WCR. We have previously used WCR to characterize the responses of the V2a class of Chx10-expressing neurons to serotonin (5-HT) in the neonatal mouse spinal cord (Zhong et al., 2010). Here we directly compare multiple aspects of the responses to 5-HT using WCR and PPR in Chx10-eCFP neurons in spinal cord slices from 2 to 4 day old mice. Cellular properties recorded in PPR and WCR were similar, but high-quality PP recordings could be maintained for significantly longer. Both WCR and PPR cells could respond to 5-HT, and although neurons recorded by PPR showed a significantly greater response to 5-HT in some parameters, the absolute differences between PPR and WCR were small. We conclude that WCR is an acceptable recording method for short-term recordings of neuromodulatory effects, but the less invasive PPR is preferable for detailed analyses and is necessary for stable recordings lasting an hour or more. PMID:23060747
The management of perforated gastric ulcers.
Leeman, Matthew Fraser; Skouras, Christos; Paterson-Brown, Simon
2013-01-01
Perforated gastric ulcers are potentially complicated surgical emergencies and appropriate early management is essential in order to avoid subsequent problems including unnecessary gastrectomy. The aim of this study was to examine the management and outcome of patients with gastric ulcer perforation undergoing emergency laparotomy for peritonitis. Patients undergoing laparotomy at the Royal Infirmary of Edinburgh for perforated gastric ulcers were identified from the prospectively maintained Lothian Surgical Audit (LSA) database over the five-year period 2007-2011. Additional data were obtained by review of electronic records and review of case notes. Forty-four patients (25 male, 19 female) were identified. Procedures performed were: 41 omental patch repairs (91%), 2 simple closures (4.5%) and 2 distal gastrectomies (4.5%; both for large perforations). Four perforated gastric tumours were identified (8.8%), 2 of which were suspected intra-operatively and confirmed histologically, 1 had unexpected positive histology and 1 had negative intra-operative histology, but follow-up endoscopy confirmed the presence of carcinoma (1 positive biopsy in 21 follow-up endoscopies); all 4 were managed without initial resection. Median length of stay was 10 days (range 4-68). Overall 7 patients died in hospital (15.9%) and there were 21 morbidities (54.5%). Registrars performed the majority of the procedures (16 alone, 21 supervised) with no significant difference in post-operative morbidity (P = 0.098) or mortality (P = 0.855), compared to consultants. Almost all perforated gastric ulcers can be effectively managed by laparotomy and omental patch repair. Initial biopsy and follow-up endoscopy with repeat biopsy is essential to avoid missing an underlying malignancy. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.
Giant perforated marginal ulcer after laparoscopic Roux-en-Y gastric bypass.
Wang, Edward; Blackham, Ruth; Tan, Jeremy; Hamdorf, Jeffrey
2017-04-11
Perforation of a marginal ulcer (MU) is a complication of Roux -en-Y gastric bypass that can be life-threatening. We report a case of a perforated MU that presented 7 months after surgery with several interesting points for discussion. Firstly, the presentation of the ulcer was cryptic with unreliable investigations. Secondly, the ulcer presented again even after anastomotic revision surgery. Finally, the ulcer and the sepsis associated with perforation presented after months of poor nutritional intake with profound hypoalbuminaemia. Perforated MUs causing malnutrition pose clinicians with the difficult decision of which operation to offer; patch repair, revision of the anastomosis or reversal surgery. This case illustrates that primary reversal surgery for a perforated recurrent MU may be the most appropriate surgical management in this clinical situation. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Altuntaş, Emine Elif; Sümer, Zeynep
2013-01-01
The purposes of this study were to investigate the biocompatibility of two different paper patches (carbon and cigarette papers) and compare the adhesion and proliferation features of L929 fibroblast cells by using 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT Test) test and scanning electron microscopy (SEM). In this study, time-dependent cytotoxic effects of cigarette and carbon papers used in repairing small traumatic TM perforations were investigated in vitro by using MTT test. And also adhesion and spreading of cells over disk surface were observed by SEM. Cytotoxicity test carried out by MTT analysis on leakage products collected from two types of paper patches at the end of 24 and 48 h revealed no cytotoxicity (P > 0.05). In SEM studies, it was observed that cells started to proliferate over disk surface as a result of 48-h incubation, and SEM revealed that the cell proliferation over cigarette paper was more compared to the one over carbon paper. We believe that this is the first study where biocompatibility and adhesion features of carbon and cigarette paper have been studied by using L929 fibroblast cell culture. As a result, biocompatibility of cigarette paper and also whether cigarette paper was superior to carbon paper in cell attachment and biocompatibility were studied. It was found, by MTT test and SEM test, that cigarette paper had a higher biocompatibility and cell attachment, and thus cigarette paper should be the patch to be preferred in cases where TM perforations are repaired by paper-patch method.
Laparoscopic Repair of Perforated Peptic Ulcer: Outcome and Associated Morbidity and Mortality
Alemrajabi, Mahdi; Safari, Saeed; Tizmaghz, Adnan; Alemrajabi, Fatemeh; Shabestanipour, Ghazaal
2016-01-01
Introduction The mainstay of treatment for perforated peptic ulcer is Omental patch closure. With the advent of laparoscopic surgery, this approach is being used for the treatment of perforated peptic ulcer. The aim of this study was to evaluate the outcome of laparoscopy in Firoozgar general hospital over a period of 18 months. The outcome of the laparoscopic approach and the associated morbidity and mortality, operation time, conversion rate and hospital stay were assessed. Methods A prospective analysis of 29 consecutive patients (mean age 37.5 years; 23 men) with perforated peptic ulcers and who had undergone laparoscopic surgery was carried over a period of 18 months from March 2014 until September 2015. Pre-operative, intra-operative, and post-operative clinical data were collectively analyzed by SPSS 19 for Windows. Results Seventeen patients had a history of cigarette smoking, 11 patients had a history of opium consumption, 19 were chronic NSAID users, 26 had Helicobacter pylori infections, and six had a co-morbid condition. Previous surgical history included laparotomy for pancreatic cancer in two patients, for sigmoid colon cancer in one patient, and for acute appendicitis in four patients. The average operating time for all cases was 47.5 + 20 min. The mean lag time between onset of symptoms and surgery was 20.4 hours. All patients underwent laparoscopic closure of the perforation with Omental patch closure. No morbidity was observed, and none of the patients needed conversion to open surgery. One patient died after 11 months of follow-up due to the progression of underlying pancreatic cancer. The mean postoperative hospital stay was 4.2 days. Conclusions The results of the laparoscopic approach for perforated peptic ulcer were promising, with no conversion to open surgery, no morbidity, and mortality. PMID:27504170
Laparoscopic Repair of Perforated Peptic Ulcer: Outcome and Associated Morbidity and Mortality.
Alemrajabi, Mahdi; Safari, Saeed; Tizmaghz, Adnan; Alemrajabi, Fatemeh; Shabestanipour, Ghazaal
2016-06-01
The mainstay of treatment for perforated peptic ulcer is Omental patch closure. With the advent of laparoscopic surgery, this approach is being used for the treatment of perforated peptic ulcer. The aim of this study was to evaluate the outcome of laparoscopy in Firoozgar general hospital over a period of 18 months. The outcome of the laparoscopic approach and the associated morbidity and mortality, operation time, conversion rate and hospital stay were assessed. A prospective analysis of 29 consecutive patients (mean age 37.5 years; 23 men) with perforated peptic ulcers and who had undergone laparoscopic surgery was carried over a period of 18 months from March 2014 until September 2015. Pre-operative, intra-operative, and post-operative clinical data were collectively analyzed by SPSS 19 for Windows. Seventeen patients had a history of cigarette smoking, 11 patients had a history of opium consumption, 19 were chronic NSAID users, 26 had Helicobacter pylori infections, and six had a co-morbid condition. Previous surgical history included laparotomy for pancreatic cancer in two patients, for sigmoid colon cancer in one patient, and for acute appendicitis in four patients. The average operating time for all cases was 47.5 + 20 min. The mean lag time between onset of symptoms and surgery was 20.4 hours. All patients underwent laparoscopic closure of the perforation with Omental patch closure. No morbidity was observed, and none of the patients needed conversion to open surgery. One patient died after 11 months of follow-up due to the progression of underlying pancreatic cancer. The mean postoperative hospital stay was 4.2 days. The results of the laparoscopic approach for perforated peptic ulcer were promising, with no conversion to open surgery, no morbidity, and mortality.
Gastric perforation secondary to metastasis from breast cancer.
Wong, Chee Siong; Gumber, Ashutosh; Kiruparan, Pasupathy; Blackmore, Alexander
2016-07-18
Gastric perforation secondary to metastasis from breast cancer occurs infrequently. We present the case of a 72-year-old postmenopausal female patient with a known history of lobular carcinoma of the breast who presented to a district general hospital with a clinical diagnosis of an acute abdomen. Further contrast-enhanced CT scan demonstrated free gas and fluid in the abdomen. She underwent emergency exploratory laparotomy and onlay Graham's omentopexy patch due to 1×1 cm prepyloric gastric perforation. Final histopathology proved the presence of metastatic malignant cells in the breast origin. We discuss the issues involved in postoperative investigation and management. 2016 BMJ Publishing Group Ltd.
Rod electrical coupling is controlled by a circadian clock and dopamine in mouse retina
Jin, Nan Ge; Chuang, Alice Z; Masson, Philippe J; Ribelayga, Christophe P
2015-01-01
Key points Rod photoreceptors play a key role in vision in dim light; in the mammalian retina, although rods are anatomically connected or coupled by gap junctions, a type of electrical synapse, the functional importance and regulation of rod coupling has remained elusive. We have developed a new technique in the mouse: perforated patch-clamp recording of rod inner segments in isolated intact retinae maintained by superfusion. We find that rod electrical coupling is controlled by a circadian clock and dopamine, and is weak during the day and stronger at night. The results also indicate that the signal-to-noise ratio for a dim light response is increased at night because of coupling. Our observations will provide a framework for understanding the daily variations in human vision as well as the basis of specific retinal malfunctions. Abstract Rod single-photon responses are critical for vision in dim light. Electrical coupling via gap junction channels shapes the light response properties of vertebrate photoreceptors, but the regulation of rod coupling and its impact on the single-photon response have remained unclear. To directly address these questions, we developed a perforated patch-clamp recording technique and recorded from single rod inner segments in isolated intact neural mouse retinae, maintained by superfusion. Experiments were conducted at different times of the day or under constant environmental conditions, at different times across the circadian cycle. We show that rod electrical coupling is regulated by a circadian clock and dopamine, so that coupling is weak during the day and strong at night. Altogether, patch-clamp recordings of single-photon responses in mouse rods, tracer coupling, receptive field measurements and pharmacological manipulations of gap junction and dopamine receptor activity provide compelling evidence that rod coupling is modulated in a circadian manner. These data are consistent with computer modelling. At night, single-photon responses are smaller due to coupling, but the signal-to-noise ratio for a dim (multiphoton) light response is increased at night because of signal averaging between coupled rods. PMID:25616058
Superimposed Fungal Ulcer after Fibrin Glue Sealant in Infectious Corneal Ulcer
Byun, Yong-Soo
2011-01-01
A healthy 27-year-old woman with a corneal ulcer underwent fibrin gluing with a bandage contact lens twice, due to an impending perforation. The ulcer lesion slowly progressed, unresponsive to topical antibiotics and amphotericin B. We removed the gluing patch and performed a corneal or scraping or biopsy with multiple amniotic membrane grafts to seal the thinned or perforated cornea. Three days after the surgery, the corneal cultures grew Fusarium, as well as Enterococcus faecalis. Three weeks after surgery, the outermost layer of amniotic membranes, serving as a temporary patch, was removed. The anterior chamber was clear without cells. The signs of infection clinically and symptomatically cleared up four weeks later. Two months after surgery, the lesion became enhanced by amniotic membranes. The use of fibrin glue in infectious keratitis should be avoided, because it not only masks the underlying lesion, but it also interferes with drug penetration into the underlying lesion. PMID:22131784
Cholinergic modulation of dopaminergic neurons in the mouse olfactory bulb.
Pignatelli, Angela; Belluzzi, Ottorino
2008-04-01
Considerable evidence exists for an extrinsic cholinergic influence in the maturation and function of the main olfactory bulb. In this study, we addressed the muscarinic modulation of dopaminergic neurons in this structure. We used different patch-clamp techniques to characterize the diverse roles of muscarinic agonists on identified dopaminergic neurons in a transgenic animal model expressing a reporter protein (green fluorescent protein) under the tyrosine hydroxylase promoter. Bath application of acetylcholine (1 mM) in slices and in enzymatically dissociated cells reduced the spontaneous firing of dopaminergic neurons recorded in cell-attached mode. In whole-cell configuration no effect of the agonist was observed, unless using the perforated patch technique, thus suggesting the involvement of a diffusible second messenger. The effect was mediated by metabotropic receptors as it was blocked by atropine and mimicked by the m2 agonist oxotremorine (10 muM). The reduction of periglomerular cell firing by muscarinic activation results from a membrane-potential hyperpolarization caused by activation of a potassium conductance. This modulation of dopaminergic interneurons may be important in the processing of sensory information and may be relevant to understand the mechanisms underlying the olfactory dysfunctions occurring in neurodegenerative diseases affecting the dopaminergic and/or cholinergic systems.
NASA Astrophysics Data System (ADS)
Rossi, Francesca; Matteini, Paolo; Menabuoni, Luca; Lenzetti, Ivo; Pini, Roberto
2011-03-01
The common procedures used to seal the scleral or conjunctival injuries are based on the traditional suturing techniques, that may induce foreign body reaction during the follow up, with subsequent inflammation and distress for the patient. In this work we present an experimental study on the laser welding of biocompatible patches onto ocular tissues, for the closure of surgical or trauma wounds. The study was performed ex vivo in animal models (porcine eyes). A penetrating perforation of the ocular tissue was performed with a surgical knife. The wound walls were approximated, and a biocompatible patch was put onto the outer surface of the tissue, in order to completely cover the wound as a plaster. The patches were prepared with a biocompatible and biodegradable polymer, showing high mechanical strength, good elasticity, high permeability for vapour and gases and rather low biodegradation. During preparation, Indocyanine Green (ICG) was included in the biopolymeric matrix, so that the films presented high absorption at 810 nm. Effective adhesion of the membranes to the ocular tissues was obtained by using diode laser light emitted from an 810 nm diode laser and delivered by means of a 300 μm core diameter optical fiber, to produce spots of local film/tissue adhesion, due to the photothermal effect at the interface. The result is an immediate closure of the wound, thus reducing post-operative complications due to inflammation.
Perforated peptic ulcer in an infant.
Feng, C Y; Hsu, W M; Chen, Y
2001-02-01
We describe a case of perforated peptic ulcer (PPU) in a 9-month-old boy. Abdominal distension was the first clinical sign of PPU. Before he developed abdominal distension, the patient had suffered from an upper respiratory tract infection with fever for about 2 weeks, which was treated intermittently with ibuprofen. A plain abdominal radiograph revealed pneumoperitoneum with a football sign. At laparotomy, a 0.8-cm perforated hole was found over the prepyloric area. Simple closure with omental patching was performed after debridement of the perforation. Pathologic examination showed chronic peptic ulcer with Helicobacter pylori infection. The postoperative course and outcome were satisfactory. The stress of underlying disease, use of ibuprofen, blood type (A), and H. pylori infection might have contributed to the development of PPU in this patient. PPU in infancy is rare and has a high mortality rate; early recognition and prompt surgical intervention are key to successful management.
Perforated peptic ulcer in an adolescent girl.
Schwartz, Shepard; Edden, Yair; Orkin, Boris; Erlichman, Matityahu
2012-07-01
A perforated peptic ulcer in a child is a rare entity. Severe abdominal pain in an ill-appearing child with a rigid abdomen and possibly with signs of shock is the typical presenting feature of this life-threatening complication of peptic ulcer disease. We present a case of a 14.5-year-old adolescent girl who developed abdominal and shoulder pain that resolved after 1 day. She was then completely well for 2 days until the abdominal and shoulder pain recurred. On examination, she appeared well, but in pain. A chest radiograph revealed a large pneumoperitoneum. She underwent emergent laparoscopic omental patch repair of a perforated ulcer on the anterior wall of her stomach. Result of a urea breath test to detect Helicobacter pylori was negative. The differential diagnosis of pneumoperitoneum in children is discussed, as are childhood perforated peptic ulcer in general, and the unique clinical features present in this case in particular.
Perforated duodenal ulcer at seven years after heart-renal transplantation: a case report.
Naritaka, Yoshihiko; Ogawa, Kenji; Shimakawa, Takeshi; Wagatsuma, Yoshihisa; Konno, Soichi; Katsube, Takao; Miyamoto, Reiko; Hamaguchi, Kanako; Hosokawa, Toshihiko
2004-01-01
We experienced a rare case of perforated duodenal ulcer that occurred at seven years after heart-kidney transplantation. This patient is reported here together with a discussion of the etiology, the selection of treatment, and perioperative management. The patient was a 46-year-old man who presented with precordial pain. In 1995, he had undergone simultaneous heart and kidney transplantation in the United States and had been on long-term immunosuppressive and corticosteroid therapy. His precordial pain started from May 24, 2002. He was examined at our hospital on May 27 and underwent emergency surgery with a diagnosis of upper gastrointestinal perforation. A 4-mm perforation was observed on the anterior wall of the duodenal bulb and panperitonitis was also present. Patch closure of the perforation was performed by pulling the omentum over the defect. Perioperative management consisted of his usual immunosuppressants together with antacid therapy. The postoperative course was good and he was discharged on hospital day 15. In this patient, the mechanism of perforation was assumed to involve sudden irritation combined with poor circulation in the duodenum and tissue ischemia, as well as a decrease of mucosal protective factors based on long-term corticosteroid therapy. Perforated duodenal ulcer is a rare problem after heart transplantation. Because the time that elapses after perforation is an important determinant of the prognosis, early diagnosis and appropriate surgical repair are essential.
Chalya, Phillipo L; Mabula, Joseph B; Koy, Mheta; Mchembe, Mabula D; Jaka, Hyasinta M; Kabangila, Rodrick; Chandika, Alphonce B; Gilyoma, Japhet M
2011-08-26
Perforated peptic ulcer is a serious complication of peptic ulcers with potential risk of grave complications. There is paucity of published reports on perforated peptic ulcer disease in our local environment. This study was conducted to evaluate the clinical presentation, management and outcome of patients with peptic ulcer perforation in our setting and to identify predictors of outcome of these patients. This was a combined retrospective and prospective study of patients who were operated for perforated peptic ulcers at Bugando Medical Centre between April 2006 and March 2011. Data were collected using a pre-tested and coded questionnaire and analyzed using SPSS computer software version 15.0. Ethical approval to conduct the study was obtained from relevant authority before the commencement of the study. A total of 84 patients were studied. Males outnumbered females by a ratio of 1.3: 1. Their median age was 28 years and the modal age group was 21-30 years. The median duration of illness was 5.8 days. The majority of patients (69.0%) had no previous history of treatment for peptic ulcer disease. The use of non-steroidal anti-inflammatory drugs, alcohol and smoking was reported in 10.7%, 85.7% and 64.3% respectively. Eight (9.5%) patients were HIV positive with a median CD4 count of 220 cells/μl. Most perforations were located on the duodenum {90.4%) with the duodenal to gastric ulcers ratio of 12.7: 1. Graham's omental patch (Graham's omentopexy) of the perforations was performed in 83.3% of cases. Complication and mortality rates were 29.8% and 10.7% respectively. The factors significantly related to complications were premorbid illness, HIV status, CD 4 count < 200 cells/μl, treatment delay and acute perforation (P < 0.001). Mortality rate was high in patients who had age ≥ 40 years, delayed presentation (>24 hrs), shock at admission (systolic BP < 90 mmHg), HIV positivity, low CD4 count (<200 cells/μl), gastric ulcers, concomitant diseases and presence of complications (P < 0.001). The median overall length of hospital stay was 14 days. Excellent results using Visick's grading system were obtained in 82.6% of surviving patients. Perforation of peptic ulcer remains a frequent clinical problem in our environment predominantly affecting young males not known to suffer from PUD. Simple closure with omental patch followed by Helicobacter pylori eradication was effective with excellent results in majority of survivors despite patients' late presentation in our center.
2011-01-01
Background Perforated peptic ulcer is a serious complication of peptic ulcers with potential risk of grave complications. There is paucity of published reports on perforated peptic ulcer disease in our local environment. This study was conducted to evaluate the clinical presentation, management and outcome of patients with peptic ulcer perforation in our setting and to identify predictors of outcome of these patients. Methods This was a combined retrospective and prospective study of patients who were operated for perforated peptic ulcers at Bugando Medical Centre between April 2006 and March 2011. Data were collected using a pre-tested and coded questionnaire and analyzed using SPSS computer software version 15.0. Ethical approval to conduct the study was obtained from relevant authority before the commencement of the study. Results A total of 84 patients were studied. Males outnumbered females by a ratio of 1.3: 1. Their median age was 28 years and the modal age group was 21-30 years. The median duration of illness was 5.8 days. The majority of patients (69.0%) had no previous history of treatment for peptic ulcer disease. The use of non-steroidal anti-inflammatory drugs, alcohol and smoking was reported in 10.7%, 85.7% and 64.3% respectively. Eight (9.5%) patients were HIV positive with a median CD4 count of 220 cells/μl. Most perforations were located on the duodenum {90.4%) with the duodenal to gastric ulcers ratio of 12.7: 1. Graham's omental patch (Graham's omentopexy) of the perforations was performed in 83.3% of cases. Complication and mortality rates were 29.8% and 10.7% respectively. The factors significantly related to complications were premorbid illness, HIV status, CD 4 count < 200 cells/μl, treatment delay and acute perforation (P < 0.001). Mortality rate was high in patients who had age ≥ 40 years, delayed presentation (>24 hrs), shock at admission (systolic BP < 90 mmHg), HIV positivity, low CD4 count (<200 cells/μl), gastric ulcers, concomitant diseases and presence of complications (P < 0.001). The median overall length of hospital stay was 14 days. Excellent results using Visick's grading system were obtained in 82.6% of surviving patients. Conclusion Perforation of peptic ulcer remains a frequent clinical problem in our environment predominantly affecting young males not known to suffer from PUD. Simple closure with omental patch followed by Helicobacter pylori eradication was effective with excellent results in majority of survivors despite patients' late presentation in our center. PMID:21871104
Preoperative factors influencing mortality and morbidity in peptic ulcer perforation.
Sivaram, P; Sreekumar, A
2018-04-01
Perforated peptic ulcer is one of the most common surgical emergencies worldwide. With the improvement in medical therapy for peptic ulcers, the number of elective surgical procedures has come down. However, the incidence of perforated peptic ulcer is still increasing and remains as a substantial health problem with significant postoperative morbidity and mortality. This study aimed to find out the association between various preoperative and intraoperative factors with the postoperative mortality and morbidity in patients operated for peptic ulcer perforation. This prospective observational study had a time based sample of 101 perforation peritonitis cases admitted to the surgical wards of a tertiary care center from February 2015 to January 2016 who underwent laparotomy, diagnosed to have peptic ulcer perforation and underwent simple closure with an omental patch. Data regarding age, gender, presenting complaints, time elapsed from the onset of symptoms to surgery, physical examination findings, comorbid diseases, laboratory and imaging findings, intraoperative findings, length of hospital stay, postoperative morbidity, and mortality were recorded and analyzed. Female gender, older age group, perforation surgery interval more than 36 h, and size of perforation more than 1 cm 2 were found to be significant factors influencing postoperative mortality and morbidity. Postoperative morbidity was also associated with comorbid diseases. Abnormal renal function on presentation was identified as an additional risk factor for postoperative morbidity and longer hospital stay. An understanding of these factors, identification of patients at risk and early intervention can help in reducing the postoperative morbidity and mortality in peptic ulcer perforation.
Global-scale patterns of forest fragmentation
Riitters, K.; Wickham, J.; O'Neill, R.; Jones, B.; Smith, E.
2000-01-01
We report an analysis of forest fragmentation based on 1-km resolution land-cover maps for the globe. Measurements in analysis windows from 81 km 2 (9 ?? 9 pixels, "small" scale) to 59,049 km 2 (243 ?? 243 pixels, "large" scale) were used to characterize the fragmentation around each forested pixel. We identified six categories of fragmentation (interior, perforated, edge, transitional, patch, and undetermined) from the amount of forest and its occurrence as adjacent forest pixels. Interior forest exists only at relatively small scales; at larger scales, forests are dominated by edge and patch conditions. At the smallest scale, there were significant differences in fragmentation among continents; within continents, there were significant differences among individual forest types. Tropical rain forest fragmentation was most severe in North America and least severe in Europe - Asia. Forest types with a high percentage of perforated conditions were mainly in North America (five types) and Europe - Asia (four types), in both temperate and subtropical regions. Transitional and patch conditions were most common in 11 forest types, of which only a few would be considered as "naturally patchy" (e.g., dry woodland). The five forest types with the highest percentage of interior conditions were in North America; in decreasing order, they were cool rain forest, coniferous, conifer boreal, cool mixed, and cool broadleaf. Copyright ?? 2000 by The Resilience Alliance.
Mapping spatial patterns with morphological image processing
Peter Vogt; Kurt H. Riitters; Christine Estreguil; Jacek Kozak; Timothy G. Wade; James D. Wickham
2006-01-01
We use morphological image processing for classifying spatial patterns at the pixel level on binary land-cover maps. Land-cover pattern is classified as 'perforated,' 'edge,' 'patch,' and 'core' with higher spatial precision and thematic accuracy compared to a previous approach based on image convolution, while retaining the...
Eto, Kei; Arimura, Yukiko; Mizuguchi, Hiroko; Nishikawa, Masazumi; Noda, Mami; Ishibashi, Hitoshi
2006-11-01
The effects of docosahexaenoic acid (DHA) and other fatty acids on P2X-receptor-mediated inward currents in rat nodose ganglion neurons were studied using the nystatin perforated patch-clamp technique. DHA accelerated the desensitization rate of the ATP-induced current. DHA showed use-dependent inhibition of the peak ATP-induced current. Other polyunsaturated fatty acids, such as arachidonic acid and eicosapentaenoic acid, displayed a similar use-dependent inhibition. The inhibitory effects of saturated fatty acids including palmitic acid and arachidic acid were weaker than those of polyunsaturated fatty acids. The results suggest that fatty acids may modulate the P2X receptor-mediated response when the channel is in the open-state.
Etonyeaku, A C; Agbakwuru, E A; Akinkuolie, A A; Omotola, C A; Talabi, A O; Onyia, C U; Kolawole, O A; Aladesuru, O A
2013-12-01
Gastro-duodenal perforations are common and may complicate peptic ulcer disease. Management is often by surgical closure. To determine the patterns of presentation and mode of management of duodenal ulcer perforations. Retrospective review of patients with duodenal ulcer perforations seen at the Obafemi Awolowo University Teaching Hospital between June 2001 and July 2011. Patients' records were reviewed for demography, duration of disease, probable risk factors, type of surgery and complications. Data obtained was analyzed using SPSS 15.0. Forty- five patients were reviewed. There were 37 males (82.2%). Mean age was 39.7years (range 15-78years). There were 10 (22.6%) students and 8(17.8%) farmers. NSAIDs abuse (11), previous peptic ulcer disease (2), and no prior dyspeptic symptoms (20) constituted 24.4%, 4.4% and 44.4% respectively of cases. Seven (16%) patients presented less than 24 hours of onset of illness. Forty one perforations (91.1%) involved the first part of duodenum. Twenty two (49%) patients had Graham's omental patch. We had one (2.2%) failed repair and six (13.3%) mortalities. Late presentation of duodenal ulcer perforation is common with high mortality. Pragmatic surgical intervention with Graham's omentopexy with broad spectrum antibiotics is still commonly practiced.
Nzarubara, Gabriel R
2005-03-01
Our understanding of the cause and treatment of peptic ulcer disease has changed dramatically over the last couple of decades. It was quite common some years ago to treat chronic ulcers surgically. These days, the operative treatment is restricted to the small proportion of ulcer patients who have complications such as perforation. The author reports seven cases of perforated duodenal ulcers seen in a surgical clinic between 1995 and 2001. Recommendations on the criteria for selecting the appropriate surgical intervention for patients with perforated duodenal ulcer are given. To decide on the appropriate surgical interventions for patients with perforated duodenal ulcer. These are case series of 7 patients who presented with perforated duodenal ulcers without a history of peptic ulcer disease. Seven patients presented with perforated duodenal ulcer 72 hours after perforation in a specialist surgical clinic in Kampala were analyzed. Appropriate management based on these patients is suggested. These patients were initially treated in upcountry clinics for acute gastritis from either alcohol consumption or suspected food poisoning. There was no duodenal ulcer history. As a result, they came to specialist surgical clinic more than 72 hours after perforation. Diagnosis of perforated duodenal ulcer was made and they were operated using the appropriate surgical intervention. Diagnosis of hangovers and acute gastritis from alcoholic consumption or suspected food poisoning should be treated with suspicion because the symptoms and signs may mimic perforated peptic ulcer in "silent" chronic ulcers. The final decision on the appropriate surgical intervention for patients with perforated duodenal ulcer stratifies them into two groups: The previously fit patients who have relatively mild physiological compromise imposed on previously healthy organ system by the perforation can withstand the operative stress of definitive procedure. The Second category includes patients who are critically ill, who poorly tolerate any operation and hence poor surgical risks. These require urgent, adequate resuscitation and simple suture with omental patch.
Surgical therapies for corneal perforations: 10 years of cases in a tertiary referral hospital
Yokogawa, Hideaki; Kobayashi, Akira; Yamazaki, Natsuko; Masaki, Toshinori; Sugiyama, Kazuhisa
2014-01-01
Purpose To report surgical therapies for corneal perforations in a tertiary referral hospital. Methods Thirty-one eyes of 31 patients (aged 62.4±18.3 years) with surgically treated corneal perforations from January 2002 to July 2013 were included in this study. Demographic data such as cause of corneal perforation, surgical procedures, and visual outcomes were retrospectively analyzed. Results The causes of corneal perforation (n=31) were divided into infectious (n=8, 26%) and noninfectious (n=23, 74%) categories. Infectious causes included fungal ulcer, herpetic stromal necrotizing keratitis, and bacterial ulcer. The causes of noninfectious keratopathy included corneal melting after removal of a metal foreign body, severe dry eye, lagophthalmos, canaliculitis, the oral anticancer drug S-1, keratoconus, rheumatoid arthritis, neurotrophic ulcer, atopic keratoconjunctivitis, and unknown causes. Initial surgical procedures included central large corneal graft (n=17), small corneal graft (n=7), and amniotic membrane transplantation (n=7). In two cases the perforation could not be sealed during the first surgical treatment and required subsequent procedures. All infectious keratitis required central large penetrating keratoplasty to obtain anatomical cure. In contrast, several surgical options were used for the treatment of noninfectious keratitis. After surgical treatment, anatomical cure was obtained in all cases. Mean postoperative best corrected visual acuity was better at 6 months (logMAR 1.3) than preoperatively (logMAR 1.8). Conclusion Surgical therapies for corneal perforations in our hospital included central large lamellar/penetrating keratoplasty, small peripheral patch graft, and amniotic membrane transplantation. All treatments were effective. Corneal perforation due to the oral anticancer drug S-1 is newly reported. PMID:25378903
Gastric cancer perforation: experience from a tertiary care hospital.
Kandel, Bishnu Prasad; Singh, Yogendra; Singh, Keshav Prasad; Khakurel, Mahesh
2013-01-01
Gastric cancer perforation can occurs in advanced stage of the disease and is often associated with a high morbidity and mortality. Peritonitis due to perforation needs emergency laparotomy and different surgical procedures can be performed for definitive treatment. Surgical procedures largely depend on the stage of the disease and general condition of the patient. This study was carried out to evaluate the outcome and role of different surgical procedures in gastric cancer perforation. Medical record of patients with gastric perforation, who were treated during ten years period, was reviewed retrospectively. Data regarding clinical presentation, surgical procedures, staging and survival of patients were obtained. Features suggestive of diffuse peritonitis were evident in all cases. The majority of the patients underwent emergency surgery except one who died during resuscitation. The majority of patients were in stage III and stage IV. Surgical procedure includes simple closure and omental patch in five patients, simple closure and gastrojejunostomy in nine patients, gastrectomy in six patients and Devine's antral exclusion in one patient. Surgical site infection was the most common (45.5%) postoperative complication. Four patients died within one month of the surgery. Three patients who underwent gastrectomy survived for one year and one patient survived for five years. Although gastric cancer perforation usually occurs in advanced stage of the disease, curative resection should be considered as far as possible.
New devices and techniques for endoscopic closure of gastrointestinal perforations
Li, Yue; Wu, Jian-Hua; Meng, Yan; Zhang, Qiang; Gong, Wei; Liu, Si-De
2016-01-01
Gastrointestinal perforations, which need to be managed quickly, are associated with high morbidity and mortality. Treatments used to close these perforations range from surgery to endoscopic therapy. Nowadays, with the development of new devices and techniques, endoscopic therapy is becoming more popular. However, there are different indications and clinical efficacies between different methods, because of the diverse properties of endoscopic devices and techniques. Successful management also depends on other factors, such as the precise location of the perforation, its size and the length of time between the occurrence and diagnosis. In this study, we performed a comprehensive review of various devices and introduced the different techniques that are considered effective to treat gastrointestinal perforations. In addition, we focused on the different methods used to achieve successful closure, based on the literature and our clinical experiences. PMID:27672268
Tzeng, Huei-Ping; Fan, Jinping; Vallejo, Jesus G.; Dong, Jian Wen; Chen, Xiongwen; Houser, Steven R.; Mann, Douglas L.
2013-01-01
HMGB1 released from necrotic cells or macrophages functions as a late inflammatory mediator, and has been shown to induce cardiovascular collapse during sepsis. Thus far, however, the effect(s) of HMGB1 in the heart are not known. We determined the effects of HMGB1 on isolated feline cardiac myocytes by measuring sarcomere shortening in contracting cardiac myocytes, intracellular Ca2+ transients using fluo-3, and L-type calcium currents using whole cell perforate configuration of the patch clamp technique. Treatment of isolated myocytes with HMGB1 (100 ng/ml) resulted in a 70% decrease in sarcomere shortening and a 50% decrease in the height of the peak Ca++ transient within 5 min (p <0.01). The immediate negative inotropic effects HMGB1 on cell contractility and calcium homeostasis were partially reversible upon washout of HMGB1. A significant inhibition of the inward L-type calcium currents also was documented by the patch clamp technique. HMGB1 induced the PKCε translocation and a PKC inhibitor significantly attenuated the negative inotropic effects of HMGB1. These studies show for the first time that HMGB1 impairs sarcomere shortening by decreasing calcium availability in cardiac myocytes through modulating membrane calcium influx, and suggest that HMGB1 maybe act as a novel myocardial depressant factor during cardiac injury. PMID:18223193
[Operative laparoscopy in the management of perforated peptic ulcer].
Schirru, Angelo; Cavaliere, Davide; Caristo, Ilario; Bianchi, Massimo; Cosce, Umberto; Mariani, Federica; Scarimbolo, Monica; Cavaliere, Paolo
2004-01-01
The aim of this retrospective study was to assess the feasibility, safety and efficacy of the laparoscopic approach in the management of perforated peptic ulcers. From January 1997 to December 2002, all patients referred to our community hospital for abdominal surgical emergencies were routinely managed by laparoscopic surgery. A review was carried out on 39 consecutive patients suffering from perforated peptic ulcers with or without generalised peritonitis. The study population comprised 24 male and 15 female patients, aged 30 to 94 years (mean age: 62 +/- 18). Laparoscopic repair was attempted in all patients. Laparoscopy afforded the correct diagnosis in all cases. Laparoscopic peritoneal washout (irrigation and suction of the entire abdominal cavity) with simple suture of the perforation proved successful in 34 patients. An additional omental patching was performed in 15 of these cases. Conversion to conventional open surgery was necessary in 5 patients. The morbidity and mortality rates were 13% and 10%, respectively. The mean operative time was 77 minutes (range: 40-120) and the mean hospital stay 9 days (range: 3-22). Laparoscopic repair of perforated ulcers is technically feasible but requires sound experience in laparoscopic abdominal emergencies. This study shows that the mini-invasive procedure is safe and effective, offering a valid alternative to traditional laparotomy.
Merali, N; Hussain, A
2015-01-01
An iatrogenic caecal perforation is rare, but a serious complication associated with significant morbidity and mortality. We present a 4min and 50s video on a new improvisation undertaken during laparoscopic management of post-polypectomy caecal perforation. Our patient presented with an acute abdomen following endoscopic polypectomy. At surgery, the site of caecal perforation was close to the appendicular base with devitalization tissue, secondary to diathermy usage. The hallmark of safety within this novel technique included fresh healthy tissue margins within the endoloop (detachable snare ligation) and ensuring no ischemic tissue was gathered. Complete freeing of the appendix and meso-appendicular base was required and securing three endoloops proximal to the site of perforation. The post-operative course was uneventful. The World Society of Emergency Surgery (WSES) 2013 guidelines suggested an early laparoscopic approach is a safe and effective treatment for colonoscopy-related colonic perforation. There are no national guidelines and the management is dictated by the clinical condition of the patient, co-morbidity, size and site of perforation as well as the scale of bowel preparation, and surgical experience. The endoloop technique described, undertaken during a laparoscopy is a novel approach. It is a simple and effective method, reminding clinicians to adapt techniques when necessary. Nevertheless, it is only limited to perforations around the appendicular base. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Merali, N.; Hussain, A.
2015-01-01
Introduction An iatrogenic caecal perforation is rare, but a serious complication associated with significant morbidity and mortality. We present a 4 min and 50 s video on a new improvisation undertaken during laparoscopic management of post-polypectomy caecal perforation. Presentation of case Our patient presented with an acute abdomen following endoscopic polypectomy. At surgery, the site of caecal perforation was close to the appendicular base with devitalization tissue, secondary to diathermy usage. The hallmark of safety within this novel technique included fresh healthy tissue margins within the endoloop (detachable snare ligation) and ensuring no ischemic tissue was gathered. Complete freeing of the appendix and meso-appendicular base was required and securing three endoloops proximal to the site of perforation. The post-operative course was uneventful. Discussion The World Society of Emergency Surgery (WSES) 2013 guidelines suggested an early laparoscopic approach is a safe and effective treatment for colonoscopy-related colonic perforation. There are no national guidelines and the management is dictated by the clinical condition of the patient, co-morbidity, size and site of perforation as well as the scale of bowel preparation, and surgical experience. Conclusion The endoloop technique described, undertaken during a laparoscopy is a novel approach. It is a simple and effective method, reminding clinicians to adapt techniques when necessary. Nevertheless, it is only limited to perforations around the appendicular base. PMID:25723744
A Flexible and Wearable Human Stress Monitoring Patch
Yoon, Sunghyun; Sim, Jai Kyoung; Cho, Young-Ho
2016-01-01
A human stress monitoring patch integrates three sensors of skin temperature, skin conductance, and pulsewave in the size of stamp (25 mm × 15 mm × 72 μm) in order to enhance wearing comfort with small skin contact area and high flexibility. The skin contact area is minimized through the invention of an integrated multi-layer structure and the associated microfabrication process; thus being reduced to 1/125 of that of the conventional single-layer multiple sensors. The patch flexibility is increased mainly by the development of flexible pulsewave sensor, made of a flexible piezoelectric membrane supported by a perforated polyimide membrane. In the human physiological range, the fabricated stress patch measures skin temperature with the sensitivity of 0.31 Ω/°C, skin conductance with the sensitivity of 0.28 μV/0.02 μS, and pulse wave with the response time of 70 msec. The skin-attachable stress patch, capable to detect multimodal bio-signals, shows potential for application to wearable emotion monitoring. PMID:27004608
Pearlman, Amy M; Terlecki, Ryan P
2018-05-02
Proximal corporal perforation at time of dilation, although rare, may occur due to factors related to patient anatomy, presence of intra-cavernosal fibrosis, and/or surgical technique. To describe tools and techniques designed to prevent and identify proximal corporal perforation, and maneuvers to minimize the risk of subsequent cylinder migration once proximal perforation has been recognized, such that the operation may proceed and result in an acceptable outcome. We discuss tips for prevention, recognition, and management of proximal corporal perforation by presenting a review of the literature as well as our preferences based on a high-volume experience with penile prosthesis surgery. Described techniques aim to minimize risk of cylinder migration in the absence of true proximal repair. Although proximal perforation may be obvious at times, particularly with a sudden loss of resistance during dilation, discrepant corporal measurements and/or dissimilar proximal deflection of the dilator should also increase the index of suspicion. Numerous techniques have been employed to theoretically reduce the risk of cylinder migration in the setting of proximal corporal perforation. These include formal corporal repair (historical), windsock repairs with non-absorbable grafts, absorbable plugs, and suture fixation of the rear tip extender or shod material covering implant tubing. Intra-operative recognition of proximal corporal perforation, coupled with understanding of surgical strategies to minimize the risk of future device migration, may allow completion of an operation that still results in an optimal outcome. Techniques described to prevent proximal migration are not strongly evidence-based, but rooted in logic and supported by high-volume implanters. Intra-operative perforation of the proximal corpora, although rare, can threaten the success of penile implant surgery, though the techniques described herein have been developed to mitigate the potential for subsequent device migration, allowing surgery to proceed and to achieve the desired clinical result. Pearlman AM, Terlecki RP. Proximal Corporal Perforation During Penile Prosthesis Surgery: Prevention, Recognition, and Review of Historical and Novel Management Strategies. J Sex Med 2018;XX:XXX-XXX. Copyright © 2018 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.
Wang, Zhi-Hong; Takada, Noriko; Uno, Hidetaka; Ishizuka, Toru; Yawo, Hiromu; Urisu, Tsuneo
2012-08-01
Positioning the sensor cell on the micropore of the sensor chip and keeping it there during incubation are problematic tasks for incubation type planar patch clamp biosensors. To solve these problems, we formed on the Si sensor chip's surface a cell trapping pattern consisting of a lattice pattern with a round area 5 μm deep and with the micropore at the center of the round area. The surface of the sensor chip was coated with extra cellular matrix collagen IV, and HEK293 cells on which a chimera molecule of channel-rhodopsin-wide-receiver (ChR-WR) was expressed, were then seeded. We examined the effects of this cell trapping pattern on the biosensor's operation. In the case of a flat sensor chip without a cell trapping pattern, it took several days before the sensor cell covered the micropore and formed an almost confluent state. As a result, multi-cell layers easily formed and made channel current measurements impossible. On the other hand, the sensor chip with cell trapping pattern easily trapped cells in the round area, and formed the colony consisted of the cell monolayer covering the micropore. A laser (473 nm wavelength) induced channel current was observed from the whole cell arrangement formed using the nystatin perforation technique. The observed channel current characteristics matched measurements made by using a pipette patch clamp. Copyright © 2012 Elsevier B.V. All rights reserved.
de Weerd, Louis; Weum, Sven; Mercer, James B
2009-09-01
The aim of this paper is to evaluate dynamic infrared thermography (DIRT) as a technique to assist in preoperative perforator selection and planning of free deep inferior epigastric perforator (DIEP) flaps. Twenty-seven patients, scheduled for secondary autologous breast reconstruction with either a free DIEP flap or superficial inferior epigastric artery flap, were included in this prospective clinical study. Preoperative mapping of perforators was performed with a hand-held Doppler and DIRT. A multidetector computer tomography scan was additionally carried out in the last 8 patients. In 23 patients a DIEP flap was used. The perforator as selected from DIRT was a suitable perforator in all DIEP flaps. The location and quality of the selected perforator from DIRT corresponded well with the multidetector computer tomography scan results. Preoperative perforator selection and planning of DIEP flaps is facilitated with the use of DIRT. The technique is noninvasive and easy to use.
Kelley, Thomas M; Kashem, Mohammed; Wang, He; McCarthy, James; Carroll, Nels D; Moser, G William; Guy, T Sloane
2017-01-01
This study reported on the treatment of Carpentier type IIIa and type IIIb mitral regurgitation (MR) with a large patch anterior mitral valve leaflet augmentation technique using CorMatrix (CorMatrix Cardiovascular Inc, Alpharetta, GA) extracellular matrix (ECM). A single-site chart review was conducted on patients who underwent anterior leaflet augmentation performed with the Da Vinci surgical robot (Intuitive Surgical, Sunnyvale, CA) or through a median sternotomy. Only patients who had anterior leaflet augmentation with porcine intestine ECM or autologous pericardium were included. Follow-up echocardiography was performed on all patients. Histologic specimens were available on ECM patches from a subset of patients who required reoperation. Between August 2011 and April 2014, 44 patients (mean age, 62.6 ± 12.2 years) underwent anterior leaflet augmentation with either porcine intestinal ECM or autologous pericardium at the Temple University Hospital in Philadelphia. Two (4%) late deaths occurred, one in each group. One patient who underwent ECM augmentation died of non-cardiac-related causes 7 months after discharge as a result of complications of chronic renal failure. The second late death occurred 5 months after discharge because of complications of a stroke in a patient in the pericardial augmentation group. Eight (32%) of the patients with ECM had recurrence of severe MR on echocardiography at an average time of 201 ± 98 days. Seven (28%) patients required reoperation because of failure of the ECM patch including perforation (4%), excessive patch dilation (20%), and suture line dehiscence (4%). In contrast, none of the patients with pericardial augmentation developed severe MR or required operation. Statistical analysis of the patients with ECM augmentation demonstrated no correlation of the following: age; sex; comorbid conditions such as diabetes, chronic obstructive pulmonary disease, and hypertension; left ventricular ejection fraction; surgical approach; annuloplasty size; or type of MR with patch failure. A lower body mass index was the only factor associated with recurrent severe regurgitation on univariate analysis (p = 0.039). Histologic study of the four available explants demonstrated intense inflammation without evidence of host integration. The remaining 15 (60%) patients had normal mitral leaflet structure and function on follow-up echocardiograms out to 12 months. For type III MR, a large anterior leaflet patch technique with porcine ECM was associated with a 32% recurrence rate of severe MR related directly to patch failure. Further research and development should be performed on the use of ECM materials with a goal to decrease the failure rate experienced in this study. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Di Carlo, I; Toro, A; Sparatore, F; Primo, S; Barbagallo, F; Di Blasi, M
2006-08-01
In elderly the incidence of the emergency gastric ulcer complications, perforation and bleeding are increasing, with a difficult management of these patients for their concomitant diseases. The aim of this work is to analyze the therapeutical approach of emergency gastric ulcer complications in elderly patients, in order to establish the factors affecting the morbidity and mortality. Patients older than 70 years, presenting gastric ulcer, observed in a tertiary University Hospital from 1995 to 2003, have been considered for the present study. Two groups of diseases have been examined: ulcer perforation and bleeding ulcer. Age, sex, risk factors, comorbidity, methods of diagnosis, ulcer characteristics, treatment, morbidity, mortality, hospitalization time and follow-up have been considered in each group. Thirteen elderly patients with perforated gastric ulcer have been observed: 9 (69.2%) females and 4 (30.8%) males with a mean age of 80.5 years (range 70-90). Four patients were hospitalized in suburban hospital with an average time between the diagnosis and the surgery of 36 h, while the remnants were hospitalized directly in our Department with a medium waiting time of about 2 h. The surgical procedures were: simple closure with omentum patch in 11 cases (84.6%), and antrectomy in 2 cases (15.4%), in which the antrum was multiply perforated. Two patients presented an ulcer larger than 2 cm treated with simple suture and omental patch without morbidity and mortality. Three patients (23%) died postoperatively, due to septic shock, ventricular fibrillation and intraoperative massive haemorrhage, 2 of these patients came from other hospitals. Twenty-eight elderly patients with bleeding gastric ulcer have been observed during the same period: 13 (46.4%) females and 15 (53.6%) males with a mean age of 79.6 years (range 71-91). Except 2 patients submitted to endoscopic treatment both with adrenaline injection, all the remnant patients were managed with medical therapy (H2-receptor antagonist or proton pump inhibitors and in 7 patients [24.1%] antihaemorrhage drugs), and clinical observation, with a endoscopic control 3-4 days after from the first endoscopy. One of the 2 patients endoscopically treated developed a ulcer perforation after 11 days, and the other one rebled, without possibility of any kind of treatment due to his instable condition of health. Three patients (10.7%) died during their hospital stay not for causes strictly due to the gastric haemorrhage. Our results suggest that the early diagnoses and early treatment are 2 basic factor on the prognosis of elderly patients with perforated gastric ulcer. The choice between simple closure, with or without vagotomy, or gastrectomy depends from preoperative and operative health conditions of the patient. In patients with ulcer larger than 2 cm, Graham's technique can be performed safely if the preoperative and intraoperative conditions are favourable. Elderly patients with gastric ulcer bleeding show an high risk of morbidity and mortality, related to the risk factors like non steroid anti-inflammatory drugs (NSAIDs) intake or smoke. Repeated endoscopy and antiulcer drugs can manage the high stage patients of Forrest's classification with a low rate of morbidity and mortality. According to literature surgical treatment should be reserved after the second failure of endoscopic treatment.
Atypical presentation of perforated peptic ulcer disease in a 12-year-old boy.
Mbarushimana, Simon; Morris-Stiff, Gareth; Thomas, George
2014-06-27
A 12-year-old boy was referred to the surgical unit with 4 h history of severe lower abdominal pain and bilious vomiting. No other symptoms were reported and there was no significant medical or family history. Examination revealed tenderness in the lower abdomen, in particular the left iliac fossa. His white cell count was elevated at 19.6×10(9)/L, with a predominant neutrophilia of 15.8×10(9)/L and a C reactive protein of <0.3 mg/L. An abdominal X-ray revealed intraperitoneal gas and a chest X-ray identified free air under both hemidiaphragms. Subsequent diagnostic laparoscopy identified a perforated duodenal ulcer that was repaired by means of an omental patch. The case illustrates that although uncommon, alternate diagnoses must be borne in mind in children presenting with lower abdominal pain and diagnostic laparoscopy is a useful tool in children with visceral perforation as it avoids treatment delays and exposure to excess radiation. 2014 BMJ Publishing Group Ltd.
Hott, Morgan E; Megerian, Cliff A; Beane, Rich; Bonassar, Lawrence J
2004-07-01
The goal of the current study was to use computer-aided design and injection molding technologies to tissue engineer precisely shaped cartilage in the shape of butterfly tympanic membrane patches out of chondrocyte-seeded calcium alginate gels. Molds were designed on SolidWorks 2000 and built out of acrylonitrile butadiene styrene (ABS) using fused deposition modeling (FDM). Tympanic membrane patches were fabricated using bovine articular chondrocytes seeded at 50 x 10 cells/mL in 2% calcium alginate gels. Molded patches were cultured in vitro for up to 10 weeks and assessed biochemically, morphologically, and histologically. Unmolded patches demonstrated outstanding dimensional fidelity, with a volumetric precision of at least 3 microL, and maintained their shape well for up to 10 weeks of in vitro culture. Glycosaminoglycan and collagen content increased steadily over 10 weeks in culture, demonstrating continual deposition of new extracellular matrix consistent with new tissue development. The use of computer-aided design and injection molding technologies allows for the fabrication of very small, precisely shaped chondrocyte-seeded calcium alginate structures that faithfully maintain their shape during in vitro culture. In vitro fabrication of tympanic membrane patches with a precisely controlled geometry may have the potential to provide a minimally invasive alternative to traditional methods for the repair of chronic tympanic membrane perforations.
Osteonecrosis related to intraosseous anesthesia: report of a case.
Woodmansey, Karl F; White, Robert K; He, Jianing
2009-02-01
Intraosseous anesthesia is an effective and increasingly used technique with few reported complications. The technique uses a specialized drill to perforate the osseous cortex where local anesthetic can then be deposited to anesthetize teeth. It has been reported that separation of the perforation drills from their plastic bases can occur because of the friction generated during osseous perforation. Prolonged rotation of the perforator drills in the bone can also cause excessive heat, which can lead to bone necrosis. This report describes a case of focal osteonecrosis subsequent to intraosseous anesthesia and discusses possible etiologies of this sequela.
Mahesh, Bijjawara; Upendra, Bidre; Vijay, Sekharappa; Arun, Kumar; Srinivasa, Reddy
2017-03-01
More than half of the perforations reported with usage of cervical pedicle screws (CPS) are lateral perforations, endangering the vertebral artery. The medial cortical pedicle screw (MCPS) technique with partial drilling of the medial cortex shifts the trajectory of pedicle screws medially, decreasing the lateral perforations. To evaluate the decrease in lateral perforations of CPS with use of MCPS technique, in relation to medial angulation. Retrospective analysis and technical report of the MCPS technique and its safety. A total of 58 patients operated on between December 2011 and May 2015 with insertion of pedicle screws from C3 to C7 were included in the study. Axial reconstructed computed tomography (CT) scan images of the inserted screws were evaluated for placement, perforations, and transverse plane angulations using the Surgimap software (Surgimap Spine 1.1.2.271 Intl. 2009 Nemaris LLC). The angulations of screws were analyzed by the type and level of placement through unpaired t test and analysis of variance test. A total of 58 patients operated on between December 2011 and May 2015 with insertion of pedicle screws from C3 to C7 were included in the study. There were 49 males and 9 females. Thirty-seven patients had cervical trauma, 17 had cervical spondylotic myelopathy, two had tumors, and two had ankylosing spondylitis. The average age was 49 years (range 18 to 80 years). The screws were inserted using the MCPS technique. All patients underwent postoperative CT scans with GE Optima CT540 16 slice CT scanner (GE Healthcare Chalfont St. Giles, Buckinghamshire, UK). Axial reconstructed images along the axis of the inserted screws were evaluated for placement and perforations. Further, all the screws were evaluated for transverse plane angulations using the Surgimap software. The angulations of screw were analyzed by the type and level of placement through unpaired t test and analysis of variance test. No funds were received by any of the authors for the purpose of the present study. A total of 324 screws were assessed with postoperative CT scans. Two hundred fifty-six were found to be placed within the pedicle and 68 (20.98%) screws were found to have perforations. Forty screws (12.34%) had grade I medial perforations, 14 screws (4.32%) had grade I lateral perforations, 10 screws (3.08%) had grade II medial perforations, and 4 screws (1.23%) had grade IIlateral perforations. The average angulation of the nonperforated screws (n=256) was 28.6° (43°-17°), that of laterally perforated screws was 20.33° (13°-24°), and that of the medially perforated screws was 34.94° (45°-20°). On statistical analysis with each series, the 99% CI range for the in-screw angles was 27.91° to 29.34°; for the laterally perforated screw series, it was 18.42° to 22.23°; and that for the medially perforated screw series was 32.97° to 36.9°. The MCPS technique represents a shift in the concept of placement of CPS from the cancellous core to the medial cortex, avoiding screw deflection laterally by the thick proximal medial cortex. The present study shows that the lateral perforations can be consistently avoided, with a medial angulation of more than 27.91°, which is the primary concern with the use of pedicle screws in lower cervical spine. Further, the MCPS technique reduces the lateral perforations at a lesser insertion angle, which is technically desirable. Copyright © 2016 Elsevier Inc. All rights reserved.
Huang, Jen-Wu; Huang, Chih-Sheng; Shih, Yu-Chung; Perng, Cherng-Kang; Lin, Yi-Ying; Wu, Szu-Hsien
2018-06-01
The endoscopic technique has been utilized to harvest muscle flaps and detect perforators of fasciocutaneous flaps. This study aimed to compare the perioperative outcomes between the endoscope-assisted technique and handheld acoustic Doppler for perforator identification in fasciocutaneous flaps.This retrospective case-control study included patients who underwent fasciocutaneous flap reconstruction for traumatic soft tissue defects. In the case group, perforator identification was assisted by the endoscope-assisted technique. In the control group, age- and sex-matched patients received handheld acoustic Doppler to detect perforators. Perioperative outcomes, flap characteristics, and postoperative complications were compared.There were 12 patients in the case group and 12 in the control group. Compared with the control group, the case group had a significantly shorter length of donor-site wounds (9 cm vs 12 cm, P = .023) and a significantly smaller proportion of patients receiving skin grafting at the donor sites (0% vs 41.7%, P = .037). The case group had a longer operative time, but the difference was not statistically significant (180 minutes vs 150 minutes, P = .367). The amount of blood loss, the time length of postoperative drainage, and complications did not significantly differ between the 2 groups.The endoscope-assisted technique for perforator identification of fasciocutaneous flaps provided less donor-site morbidity and a significantly shorter length of donor-site wounds than the conventional handheld acoustic Doppler, which suggests that this technique could be a valuable alternative when a precise design is indicated.
Valentino's syndrome a perforated peptic ulcer mimicking acute appendicitis.
Wijegoonewardene, Sandeep Indika; Stein, Joel; Cooke, David; Tien, Alan
2012-06-28
The authors present a case of a 30-year-old female who presented with symptoms and signs suggestive of appendicitis accompanied by elevated inflammatory markers. The patient was consented and taken to theatre for laparoscopic apendicectomy. At operation, the appendix was found to be normal but with surrounding turbid fluid in the right paracolic gutter and subhepatic space. On further inspection, a perforated pre pyloric ulcer was discovered. This was managed laparoscopically with a peritoneal lavage and falciform ligament patch repair. The patient made a good recovery and was discharged 2 days later. At 6 week follow-up the patient had an upper gastrointestinal (GI) endoscopy which showed complete healing of the ulcer. At 6 week follow-up the patient had an upper GI endoscopy which showed complete healing of the ulcer.
Ali, Wasif Mohammad; Ansari, M M; Rizvi, Syed Amjad Ali; Rabb, A Z; Mansoor, Tariq; Harris, Syed Hassan; Akhtar, Mohd Sadiq
2018-02-01
Duodenal ulcer perforations have been known since 1600 AD. It is a common surgical emergency and every surgeon will encounter it. The perforation size of >2 cm has been used as the criteria for defining Giant duodenal ulcers. The management of giant duodenal perforations in hemodynamically unstable patient with comorbid condition is taxing because of high incidence of the postoperative leak and mortality. We have used the simple technique of Triple Tube Ostomy after the primary closure of the defect with encouraging results. It is a retrospective study done at the J. N medical college AMU Aligarh from May 2005 to May 2015. Hemodynamically unstable patients who have presented to the emergency with preoperative diagnoses of giant duodenal ulcer perforation and had undergone triple tube ostomy with primary repair of the perforation were included in the study. There were 34 patients of giant duodenal perforation who presented in shock. All of them underwent triple-tube-ostomy after primary repair of the duodenum. Thirty-two patients recovered with two mortalities (5.8 %). Several definite surgical techniques have been described for the management of giant duodenal ulcer perforation but they are complex, have very high morbidity and mortality rate and require an expert surgeon. A close retrospective scrutiny of the patients suggests that simple triple-tube-ostomy technique which is based on the principle of damage control surgery has good postoperative results Therefore, we recommend it as the procedure of choice in these patients.
Garbacea, Antoanela; Lozada, Jaime L; Church, Christopher A; Al-Ardah, Aladdin J; Seiberling, Kristin A; Naylor, W Patrick; Chen, Jung-Wei
2012-08-01
Transcrestal sinus membrane elevation is a surgical procedure performed to increase the bone volume in the maxillary sinus cavity. Because of visual limitations, the potential for maxillary sinus membrane perforations may be greater than with the lateral approach technique. The aim of this study was to macroscopically investigate ex vivo the occurrence of sinus membrane perforation during surgery using 3 transcrestal sinus floor elevation methods. Twenty fresh human cadaver heads, with 40 intact sinuses, were used for simultaneous sinus membrane elevation, placement of graft material, and dental implants. Real-time sinus endoscopy, periapical digital radiographs, and cone-beam computerized tomography (CBCT) images were subsequently used to evaluate the outcome of each surgical procedure. Perforation rates for each of the 3 techniques were then compared using a significance level of P < .05. No statistically significant differences in the perforation rate (P = .79) were found among the 3 surgical techniques. Although the sinus endoscope noted a higher frequency of perforations at the time of implant placement as compared with instrumentation or graft insertion, the difference was not statistically significant (P = .04). The CBCT readings were judged to be more accurate for identifying evidence of sinus perforations than the periapical radiographs when compared with the direct visualization with the endoscope. This pilot study demonstrated that a sinus membrane perforation can occur at any time during the sinus lift procedure, independent of the surgical method used.
[Laparoscopic surgery for perforated peptic ulcer].
Yasuda, Kazuhiro; Kitano, Seigo
2004-03-01
Laparoscopic surgery has become the treatment of choice for the management of perforated peptic ulcer. The advantages of laparoscopic repair for perforated peptic ulcer include less pain, a short hospital stay, and an early return to normal activity. Although the operation time of laparoscopic surgery is significantly longer than that of open surgery, laparoscopic technique is safe, feasible, and with morbidity and mortality comparable to that of the conventional open technique. To benefit from the advantages offered by minimally invasive laparoscopic technique, further study will need to determine whether laparoscopic surgery is safe in patients with generalized peritonitis or sepsis.
Surgical technique for reconstruction of the nasal septum: the pericranial flap.
Paloma, V; Samper, A; Cervera-Paz, F J
2000-01-01
We describe a new technique for the surgical reconstruction of large-sized anterior septal perforations based on the pericranial flap. The technique requires a standard open rhinoplasty combined with a pericranial flap harvested after a bicoronal approach and tunnelled to the nasal cavity. We present the case of a man with complete destruction of the nasal septum as a result of chronic cocaine abuse. Surgery resulted in a permanent and complete closure of the perforation. The main advantage of this technique is the use of well-vascularized autogenous tissue and the minimal donor site morbidity. This technique provides a new method to close large nasal perforations. Copyright 2000 John Wiley & Sons, Inc. Head Neck 22: 90-94, 2000.
Christ, Torsten; Kovács, Peter P; Acsai, Karoly; Knaut, Michael; Eschenhagen, Thomas; Jost, Norbert; Varró, András; Wettwer, Erich; Ravens, Ursula
2016-10-05
The Na(+)/Ca(2+) exchanger (NCX) plays a major role in myocardial Ca(2+) homoeostasis, but is also considered to contribute to the electrical instability and contractile dysfunction in chronic atrial fibrillation (AF). Here we have investigated the effects of the selective NCX blocker SEA0400 in human right atrial cardiomyocytes from patients in sinus rhythm (SR) and AF in order to obtain electrophysiological evidence for putative antiarrhythmic activity of this new class of drugs. Action potentials were measured in right atrial trabeculae using conventional microelectrodes. Human myocytes were enzymatically isolated. Rat atrial and ventricular cardiomyocytes were used for comparison. Using perforated-patch, NCX was measured as Ni(2+)-sensitive current during ramp pulses. In ruptured-patch experiments, NCX current was activated by changing the extracellular Ca(2+) concentration from 0 to 1mM in Na(+)-free bath solution (100mM Na(+) intracellular, "Hilgemann protocol"). Although SEA0400 was effective in rat cardiomyocytes, 10µM did not influence action potentials and contractility, neither in SR nor AF. SEA0400 (10μM) also failed to affect human atrial NCX current measured with perforated patch. With the "Hilgemann protocol" SEA0400 concentration-dependently suppressed human atrial NCX current, and its amplitude was larger in AF than in SR cardiomyocytes. Our results confirm higher NCX activity in AF than SR. SEA0400 fails to block Ni(2+)-sensitive current in human atrial cells unless unphysiological conditions are used. We speculate that block of NCX with SEA0400 depends on intracellular Na(+) concentration. Copyright © 2016 Elsevier B.V. All rights reserved.
Development of the technology for the fabrication of reliable laminar from control panels
NASA Technical Reports Server (NTRS)
Meade, L. E.; Kays, A. O.; Ferrill, R. S.; Young, H. R.
1977-01-01
Materials were assessed and fabrication techniques were developed for use in the manufacture of wing surface materials compatible with the application of both aluminum alloys and nonmetallic composites. The concepts investigated included perforations and slots in the metallic test panels and microporosity and perforations in the composite test panels. Perforations were produced in the metallic test panels by the electron beam process and slots were developed by controlled gaps between the metal sheets. Microporosity was produced in the composite test panels by the resin bleed process, and perforations were produced by the fugitive fiber technique. Each of these concepts was fabricated into test panels, and air flow tests were conducted on the panels.
Zhang, H; Bolton, T B
1995-01-01
1. Single-channel recordings were made from cell-attached and isolated patches, and whole-cell currents were recorded under voltage clamp from single smooth muscle cells obtained by enzymic digestion of a small branch of the rat mesenteric artery. 2. In single voltage-clamped cells 1 mM uridine diphosphate (UDP) or guanidine diphosphate (GDP) added to the pipette solution, or pinacidil (100 microM) a K-channel opener (KCO) applied in the bathing solution, evoked an outward current of up to 100pA which was blocked by glibenclamide (10 microM). In single cells from which recordings were made by the 'perforated patch' (nystatin pipette) technique, metabolic inhibition by 1 mM NaCN and 10 mM 2-deoxy-glucose also evoked a similar glibenclamide-sensitive current. 3. Single K-channel activity was observed in cell-attached patches only infrequently unless the metabolism of the cell was inhibited, whereupon channel activity blocked by glibenclamide was seen; pinacidil applied to the cell evoked similar glibenclamide-sensitive channel activity. If the patch was pulled off the cell to form an isolated inside-out patch, similar glibenclamide-sensitive single-channel currents were observed in the presence of UDP and/or pinacidil to those seen in cell-attached mode; channel conductance was 20 pS (60:130 K-gradient) and openings showed no voltage-dependence and noisy inward currents, typical of the nucleoside diphosphate (NDP) activated K-channel (KNDP) seen previously in rabbit portal vein. 4. Formation of an isolated inside-out patch into an ATP-free solution did not increase the probability of channel opening which declined with time even when some single-channel activity had occurred in the cell-attached mode before detachment. However, application of 1 mM UDP or GDP, but not ATP, to inside-out patches evoked single-channel activity. Application of ATP-free solution to isolated patches, previously exposed to ATP and in which channel activity had been seen, did not evoke channel activity. 5. It is concluded that small conductance K-channels (KNDP) open in smooth muscle cells from this small artery in response to UDP or GDP acting from the inside, or pinacidil acting from the outside; the same channels open during inhibition of metabolism presumably mainly due to the rise in nucleoside diphosphates, but a fall in the ATP concentration on the inside of the channel did not by itself evoke channel activity.(ABSTRACT TRUNCATED AT 400 WORDS) PMID:7735693
Laparoscopic removal of an intra-abdominal intrauterine device: case and systematic review.
Gill, Richdeep S; Mok, Dereck; Hudson, Matthew; Shi, Xinzhe; Birch, Daniel W; Karmali, Shahzeer
2012-01-01
Uterine perforation by intrauterine devices (IUDs) is a rare but well recognized complication. In the past, the presence of adhesions and perforation of viscera often resulted in the need for a laparotomy to remove the IUD. However, advances in laparoscopic technique have allowed surgeons to safely retrieve perforated IUDs. In this review, we analyze uterine perforation by an IUD and assess laparoscopic vs. open methods for removal of a perforated IUD. A systematic search strategy was applied to several electronic bibliographic databases: Medline/Pubmed, Embase, Cochrane Library, and OCLC PapersFirst. Key words used were IUD, laparoscopy, and uterine perforation. One hundred seventy-nine cases of attempted laparoscopic removal of perforated IUDs were identified in the English literature between 1970 and 2009. Patient age ranged from 17 to 49 years. Diagnostic laparoscopy was performed in all 179 cases reported. Laparoscopic removal of perforated IUDs was achieved successfully in 64.2% (115/179) of cases. This systematic review highlights how advances in laparoscopic technique and skill have allowed surgeons to safely retrieve IUDs without laparotomy. We recommend an attempt at laparoscopic removal as first-line treatment in symptomatic patients and as a reasonable treatment option in asymptomatic patients. Copyright © 2012 Elsevier Inc. All rights reserved.
Chan, Chris Yin Wei; Kwan, Mun Keong; Saw, Lim Beng
2010-01-01
The objective of this cadaveric study is to determine the safety and outcome of thoracic pedicle screw placement in Asians using the funnel technique. Pedicle screws have superior biomechanical as well as clinical data when compared to other methods of instrumentation. However, misplacement in the thoracic spine can result in major neurological implications. There is great variability of the thoracic pedicle morphometry between the Western and the Asian population. The feasibility of thoracic pedicle screw insertion in Asians has not been fully elucidated yet. A pre-insertion radiograph was performed and surgeons were blinded to the morphometry of the thoracic pedicles. 240 pedicle screws were inserted in ten Asian cadavers from T1 to T12 using the funnel technique. 5.0 mm screws were used from T1 to T6 while 6.0 mm screws were used from T7 to T12. Perforations were detected by direct visualization via a wide laminectomy. The narrowest pedicles are found between T3 and T6. T5 pedicle width is smallest measuring 4.1 +/- 1.3 mm. There were 24 (10.0%) Grade 1 perforations and only 1 (0.4%) Grade 2 perforation. Grade 2 or worse perforation is considered significant perforation which would threaten the neural structures. There were twice as many lateral and inferior perforations compared to medial perforations. 48.0% of the perforations occurred at T1, T2 and T3 pedicles. Pedicle fracture occurred in 10.4% of pedicles. Intra-operatively, the absence of funnel was found in 24.5% of pedicles. In conclusion, thoracic pedicle screws using 5.0 mm at T1-T6 and 6.0 mm at T7-T12 can be inserted safely in Asian cadavers using the funnel technique despite having smaller thoracic pedicle morphometry.
[Preoperative CT angiography for planning free perforator flaps in breast reconstruction].
Kuekrek, H; Müller, D; Paepke, S; Dobritz, M; Machens, H-G; Giunta, R E
2011-04-01
Preoperative Doppler ultrasonography for planning free perforator flaps is widely established to identify preoperatively perforators. The method allows one to localise the penetrating point of the perforator through the abdominal fascia. By this means it is not possible to see the intramuscular course or the position of the perforator in relation to the inferior epigastric artery. Lately the technique of computed tomographic angiography provides an opportunity for visualising the course of perforator vessels in these tissues. This paper summarises our experience with the preoperative CT angiography in our breast centre. Since spring 2009 we have reconstructed the breasts of 44 female patients by using free flaps from the lower abdominal wall. 6 of these were bilateral. In a total number of 50 breast reconstructions we used 23 deep inferior epigastric perforator (DIEP) flaps and 27 muscle-sparing transverse rectus abdominis muscle (TRAM) flaps. In addition to the preoperative ultrasonography, a CT angiography of the lower abdomen was conducted in 29 patients. On average they showed at least 2 perforators on the left as well as right abdominal sides, which could be used as flap vessels based on their signal intensity. Based on their estimated microsurgical dissection complexity, the perforator vessels could be classified into 3 groups: 1) direct perforators of category A with short intramuscular course (39%), 2) perforators with long intramuscular course of category B (50%) and 3) "turn around" perforators of category C, which pass medially around the rectus abdominis (11%). The technique of CT angiography permits a reliable preoperative visualisation of perforators in their entire course and facilitates the selection of the supplying perforator as well as the intraoperative procedure for the surgeon. The suggested classification of perforators into 3 groups simplifies the preoperative assessment of the microsurgical dissection effort. Compared to the commonly used Doppler ultrasonography there are disadvantages like the additional cost factor and the radiation exposure. However, in our experience the more detailed planning increases the safety of flap raising and reduces surgery time, so that we consider CT angiography a positive tool to facilitate free perforator flaps. © Georg Thieme Verlag KG Stuttgart · New York.
Perforated peptic ulcer - an update
Chung, Kin Tong; Shelat, Vishalkumar G
2017-01-01
Peptic ulcer disease (PUD) affects 4 million people worldwide annually. The incidence of PUD has been estimated at around 1.5% to 3%. Perforated peptic ulcer (PPU) is a serious complication of PUD and patients with PPU often present with acute abdomen that carries high risk for morbidity and mortality. The lifetime prevalence of perforation in patients with PUD is about 5%. PPU carries a mortality ranging from 1.3% to 20%. Thirty-day mortality rate reaching 20% and 90-d mortality rate of up to 30% have been reported. In this review we have summarized the current evidence on PPU to update readers. This literature review includes the most updated information such as common causes, clinical features, diagnostic methods, non-operative and operative management, post-operative complications and different scoring systems of PPU. With the advancement of medical technology, PUD can now be treated with medications instead of elective surgery. The classic triad of sudden onset of abdominal pain, tachycardia and abdominal rigidity is the hallmark of PPU. Erect chest radiograph may miss 15% of cases with air under the diaphragm in patients with bowel perforation. Early diagnosis, prompt resuscitation and urgent surgical intervention are essential to improve outcomes. Exploratory laparotomy and omental patch repair remains the gold standard. Laparoscopic surgery should be considered when expertise is available. Gastrectomy is recommended in patients with large or malignant ulcer. PMID:28138363
Perforated peptic ulcer - an update.
Chung, Kin Tong; Shelat, Vishalkumar G
2017-01-27
Peptic ulcer disease (PUD) affects 4 million people worldwide annually. The incidence of PUD has been estimated at around 1.5% to 3%. Perforated peptic ulcer (PPU) is a serious complication of PUD and patients with PPU often present with acute abdomen that carries high risk for morbidity and mortality. The lifetime prevalence of perforation in patients with PUD is about 5%. PPU carries a mortality ranging from 1.3% to 20%. Thirty-day mortality rate reaching 20% and 90-d mortality rate of up to 30% have been reported. In this review we have summarized the current evidence on PPU to update readers. This literature review includes the most updated information such as common causes, clinical features, diagnostic methods, non-operative and operative management, post-operative complications and different scoring systems of PPU. With the advancement of medical technology, PUD can now be treated with medications instead of elective surgery. The classic triad of sudden onset of abdominal pain, tachycardia and abdominal rigidity is the hallmark of PPU. Erect chest radiograph may miss 15% of cases with air under the diaphragm in patients with bowel perforation. Early diagnosis, prompt resuscitation and urgent surgical intervention are essential to improve outcomes. Exploratory laparotomy and omental patch repair remains the gold standard. Laparoscopic surgery should be considered when expertise is available. Gastrectomy is recommended in patients with large or malignant ulcer.
Perforated peptic ulcer disease: mid-term outcome among Iranian population.
Kamani, Freshteh; Moghimi, Mehrdad; Marashi, Seyed Ali; Peyrovi, Habibollah; Sheikhvatan, Mehrdad
2010-06-01
The aim of this study was to evaluate midterm outcome of patients with perforated peptic ulcer disease and to determine the main predictors of mid-term mortality. Demographic and clinical characteristics of 56 patients with the diagnosis of perforated peptic ulcer who were hospitalized in Taleghani Hospital over a 10-year period (19962005) were retrospectively collected, and in-hospital mortality and morbidity were determined. Patients were also followed for one month, one year and five years after the operation. Among these patients, 85.5% were treated with omental patch closure, 7.1% underwent vagotomy pyloroplasty, 5.3% underwent concurrent vagotomy and gastrojejunostomy, and 1.8% underwent antrectomy. In-hospital mortality and morbidity were 5.3% and 48.2%, respectively. Survival rates at one month, one year and five years after the operation were 92.9%, 89.3% and 78.6%, respectively. Advanced age (p=0.001), preoperative shock (p=0.003), history of malignancy before surgery (p=0.001), treatment delay (p=0.028), intensive care unit admission (p=0.032), and size of ulcer >5 cm (p=0.043) were the main predictors of five-year mortality in the followed patients. Mid-term mortality of treated perforated peptic ulcer disease among our population was notable, and the main predictors of mortality included advanced age, history of malignancy, treatment delay, intensive care unit admission, and ulcer size.
Provence, Aaron; Angoli, Damiano; Petkov, Georgi V
2018-01-01
Voltage-gated K V 7 channels (K V 7.1 to K V 7.5) are important regulators of the cell membrane potential in detrusor smooth muscle (DSM) of the urinary bladder. This study sought to further the current knowledge of K V 7 channel function at the molecular, cellular, and tissue levels in combination with pharmacological tools. We used isometric DSM tension recordings, ratiometric fluorescence Ca 2+ imaging, amphotericin-B perforated patch-clamp electrophysiology, and in situ proximity ligation assay (PLA) in combination with the novel compound N -(2,4,6-trimethylphenyl)-bicyclo[2.2.1]heptane-2-carboxamide (ML213), an activator of K V 7.2, K V 7.4, and K V 7.5 channels, to examine their physiologic roles in guinea pig DSM function. ML213 caused a concentration-dependent (0.1-30 µ M) inhibition of spontaneous phasic contractions in DSM isolated strips; effects blocked by the K V 7 channel inhibitor XE991 (10 µ M). ML213 (0.1-30 µ M) also reduced pharmacologically induced and nerve-evoked contractions in DSM strips. Consistently, ML213 (10 µ M) decreased global intracellular Ca 2+ concentrations in Fura-2-loaded DSM isolated strips. Perforated patch-clamp electrophysiology revealed that ML213 (10 µ M) caused an increase in the amplitude of whole-cell K V 7 currents. Further, in current-clamp mode of the perforated patch clamp, ML213 hyperpolarized DSM cell membrane potential in a manner reversible by washout or XE991 (10 µ M), consistent with ML213 activation of K V 7 channel currents. Preapplication of XE991 (10 µ M) not only depolarized the DSM cells, but also blocked ML213-induced hyperpolarization, confirming ML213 selectivity for K V 7 channel subtypes. In situ PLA revealed colocalization and expression of heteromeric K V 7.4/K V 7.5 channels in DSM isolated cells. These combined results suggest that ML213-sensitive K V 7.4- and K V 7.5-containing channels are essential regulators of DSM excitability and contractility. Copyright © 2017 by The American Society for Pharmacology and Experimental Therapeutics.
Inward current activated by carbachol in rat intestinal smooth muscle cells.
Ito, S; Ohta, T; Nakazato, Y
1993-01-01
1. Carbachol (0.1 mM or 10 microM)-evoked inward currents were studied with standard and perforated whole-cell patch clamp techniques in smooth muscle cells isolated from rat small intestine. The intracellular free Ca2+ concentration was monitored simultaneously with the fura-2 method. 2. With a K(+)-containing pipette solution, carbachol produced an inward current at -60 mV and a large outward current at -20 mV. 3. When NaCl was substituted for KCl in the external and pipette solutions, carbachol elicited inward currents at holding potentials more inside-negative than 0 mV. The reversal potential of the carbachol-induced current altered when external chloride (-0.9 mV) was replaced by iodide (-21.2 mV), thiocyanate (-27.0 mV) and glutamate (18.2 mV). The carbachol-induced current at -60 mV was slightly decreased by the replacement of external NaCl with Tris-Cl. 4. The carbachol-induced inward current at -60 mV was accompanied by an increase in the intracellular concentration of free Ca2+. Both responses to carbachol were observed 2 min after exposure of the cells to a Ca(2+)-free solution containing 2 mM EGTA. 5. Intracellular application of heparin inhibited the inward current and Ca2+ transient responses to carbachol but not those to caffeine (10 mM). An inward current and Ca2+ transient were elicited after the patch membrane was ruptured at -60 mV, using a patch pipette containing inositol 1,4,5-trisphosphate (InsP3). 6. It is concluded that the carbachol-induced inward current is due to increases in membrane Cl- and Na+ conductances. Ca2+ released from InsP3-sensitive stores may play a role in increasing both conductances. PMID:7508506
Sheriff, Hemin Oathman; Mahmood, Kawa Abdullah; Hamawandi, Nzar; Mirza, Aram Jamal; Hawas, Jawad; Moreno, Esther Granell; Clavero, Juan Antonio; Hankins, Christopher; Masia, Jaume
2018-05-18
The supraclavicular artery flap is an excellent flap for head and neck reconstruction. The aim of this study is to assess imaging techniques to define the precise vascular boundaries of this flap. Six imaging techniques were used for supraclavicular artery mapping in 65 cases; handheld Doppler, triplex ultrasound, computed tomography angiography, magnetic resonance angiography, digital subtraction angiography, and indocyanine green angiography. We checked the site of the perforators, the course of a supraclavicular artery, and anatomical mapping of the supraclavicular artery. Handheld Doppler identified perforators' sites in 80% of the cases but showed no results for the course of the vessel. Triplex ultrasound identified the site of perforators in 52.9%, and partial mapping of the course of a supraclavicular artery in 64.7% of the cases. Computerized tomography angiography showed the site of perforators in 60%, and the course of supraclavicular artery completely in 45%, and partially in an additional 30%of the cases examined. Magnetic resonance angiography showed negative results for all parameters. Digital subtraction angiography showed the partial course of a supraclavicular artery in 62.5%, but showed no perforators. Indocyanine green angiography showed the site of perforators in 60% and a partial course of supraclavicular artery distal to perforators in 60%.Anatomical mapping of the vessel was possible with computerized tomography angiogram completely in 45%, and partially in 30%, and was also possible with indocyanine green angiography partially in 60%. Computerized tomography angiography showed best results in the mapping of the supraclavicular artery, but with an inability to define the perforator perfusion territories, and also with risks of irradiation, while indocyanine green angiography is a good alternative as it could precisely map the superficial course of the artery and angiosomes, with no radiation exposure. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Ugochukwu, A I; Amu, O C; Nzegwu, M A; Dilibe, U C
2013-01-01
Acute perforated peptic ulcer is a leading cause of generalized peritonitis and its management has continued to be a challenging task in our environment. There is a paucity of published reports on acute perforated peptic ulcers in our environment. This study was conducted to evaluate the different pattern of risk factors clinical presentations, management and clinical outcome of patients with acute perforated peptic ulcer in our setting and to highlight the factors that continue to account for the high mortality and morbidity as seen here. A retrospective study where data of seventy-six (76) patients managed for generalized peritonitis due to acute peptic ulcer perforation over a five year period (January 2006-December 2010) were retrieved from medical records of Enugu State University of Science and Technology Hospital (ESUTH). The patients' biodata, clinical and operative findings and treatment outcome were extracted and analysed, after institutional ethical approval was secured. All other cases of generalized peritonitis not traceable to acute peptic ulcer perforation were excluded from the study. There were76 patients; 58 males and 18 females (M:F = 3.2:1) Their ages ranged from 20 to 80years with a mean of 39.5yr and SD ± 13.10years. Majority of the patients 49(64.4%) were 40years of age and below and only 24 (31.6%) had a previous history suggestive of chronic peptic ulcer disease. Twenty five (32.9%) patients presented within 24 h of onset of symptoms of perforation with a mortality of 8.0%. Slightly more than half of our patients 39(51.3%) presented between 24 and 48 h with mortality of 17.9%. Twelve patients (15.8%) presented between 48 and 72 h and the mortality in this group was 58.3%. The latter two groups accounted for most of the mortality in our series. All perforations were anterior perforations within the first 2.5 cm of the duodenum and all had simple closure with pedicled omental patch and peritoneal toilet with copious volumes of warm normal saline. Postoperatively all received Helicobacter pylori eradication therapy and proton pump inhibitors for at least two months. Patient groups who presented early had low mortality rates, but patient groups who presented late had higher mortality rates. Overall mortality was 21%. Copyright © 2013. Published by Elsevier Ltd.
Pneumatosis intestinalis with complete remission: a case report.
Saber, Aly
2009-04-29
Pneumatosis cystoides intestinalis is a rare disease characterized by presence of multilocular cysts in the gastrointestinal wall. Rarely, patients may experience symptoms secondary to the cysts. The pathogenesis of pneumatosis cystoides intestinalis is still unclear and many theories have been advocated to explain the exact origin. Complications occur in about 3% of cases and include obstruction, intussusception, volvulus, haemorrhage and intestinal perforation. The author reported a male patient aged 56 years presented to the emergency department with acute upper abdominal pain. Widespread variable sized serosal intestinal air cysts were seen at the first look involving long segment of jejunum and ileum. Perforated duodenal ulcer, as the cause of generalized peritonitis, was repaired with direct closure and omental patch. A second laparotomy, was done and exploration was systematically performed and denoted hugely distended stomach with cicatrisation at the site of previous closure of perforated duodenal ulcer and the whole length of small gut was completely free from the already described pneumatosis cystoides intestinalis. The pneumatosis cystoides intestinalis is a rare disease and suspicion of this disease process should be based on imaging and clinical finding. The therapy can be conservative or surgical in restricted situations.
Expression and function of K(V)2-containing channels in human urinary bladder smooth muscle.
Hristov, Kiril L; Chen, Muyan; Afeli, Serge A Y; Cheng, Qiuping; Rovner, Eric S; Petkov, Georgi V
2012-06-01
The functional role of the voltage-gated K(+) (K(V)) channels in human detrusor smooth muscle (DSM) is largely unexplored. Here, we provide molecular, electrophysiological, and functional evidence for the expression of K(V)2.1, K(V)2.2, and the electrically silent K(V)9.3 subunits in human DSM. Stromatoxin-1 (ScTx1), a selective inhibitor of K(V)2.1, K(V)2.2, and K(V)4.2 homotetrameric channels and of K(V)2.1/9.3 heterotetrameric channels, was used to examine the role of these channels in human DSM function. Human DSM tissues were obtained during open bladder surgeries from patients without a history of overactive bladder. Freshly isolated human DSM cells were studied using RT-PCR, immunocytochemistry, live-cell Ca(2+) imaging, and the perforated whole cell patch-clamp technique. Isometric DSM tension recordings of human DSM isolated strips were conducted using tissue baths. RT-PCR experiments showed mRNA expression of K(V)2.1, K(V)2.2, and K(V)9.3 (but not K(V)4.2) channel subunits in human isolated DSM cells. K(V)2.1 and K(V)2.2 protein expression was confirmed by Western blot analysis and immunocytochemistry. Perforated whole cell patch-clamp experiments revealed that ScTx1 (100 nM) inhibited the amplitude of the voltage step-induced K(V) current in freshly isolated human DSM cells. ScTx1 (100 nM) significantly increased the intracellular Ca(2+) level in DSM cells. In human DSM isolated strips, ScTx1 (100 nM) increased the spontaneous phasic contraction amplitude and muscle force, and enhanced the amplitude of the electrical field stimulation-induced contractions within the range of 3.5-30 Hz stimulation frequencies. These findings reveal that ScTx1-sensitive K(V)2-containing channels are key regulators of human DSM excitability and contractility and may represent new targets for pharmacological or genetic intervention for bladder dysfunction.
Otologic blast injuries due to the Kenya embassy bombing.
Helling, Eric Robert
2004-11-01
Otologic injuries are frequently associated with large blasts. On August 7, 1998, a large truck bomb exploded next to the U.S. Embassy in Nairobi, Kenya. Initial patient findings and care are reviewed. Five months later, an otologic screening and care mission was then sent to comprehensively screen all remaining blast victims on site in Nairobi and to determine degree of persistent injury. Surgical care appropriate for an outpatient environment was provided. Five of 14 tympanic membranes without intervention failed to heal, while 3 of 3 with previous intervention had. Blast injury severity did not correlate to distance from blast epicenter. This may be due to channeling of the blast through the embassy building and an unpredictable pattern of blast overpressure within the building. It is recommended that comprehensive otologic screening be performed after blast events to identify occult injuries and improve outcomes. Early intervention for tympanic membrane perforation (suctioning, eversion of perforations, and paper patch) is recommended.
Cell-Detection Technique for Automated Patch Clamping
NASA Technical Reports Server (NTRS)
McDowell, Mark; Gray, Elizabeth
2008-01-01
A unique and customizable machinevision and image-data-processing technique has been developed for use in automated identification of cells that are optimal for patch clamping. [Patch clamping (in which patch electrodes are pressed against cell membranes) is an electrophysiological technique widely applied for the study of ion channels, and of membrane proteins that regulate the flow of ions across the membranes. Patch clamping is used in many biological research fields such as neurobiology, pharmacology, and molecular biology.] While there exist several hardware techniques for automated patch clamping of cells, very few of those techniques incorporate machine vision for locating cells that are ideal subjects for patch clamping. In contrast, the present technique is embodied in a machine-vision algorithm that, in practical application, enables the user to identify good and bad cells for patch clamping in an image captured by a charge-coupled-device (CCD) camera attached to a microscope, within a processing time of one second. Hence, the present technique can save time, thereby increasing efficiency and reducing cost. The present technique involves the utilization of cell-feature metrics to accurately make decisions on the degree to which individual cells are "good" or "bad" candidates for patch clamping. These metrics include position coordinates (x,y) in the image plane, major-axis length, minor-axis length, area, elongation, roundness, smoothness, angle of orientation, and degree of inclusion in the field of view. The present technique does not require any special hardware beyond commercially available, off-the-shelf patch-clamping hardware: A standard patchclamping microscope system with an attached CCD camera, a personal computer with an imagedata- processing board, and some experience in utilizing imagedata- processing software are all that are needed. A cell image is first captured by the microscope CCD camera and image-data-processing board, then the image data are analyzed by software that implements the present machine-vision technique. This analysis results in the identification of cells that are "good" candidates for patch clamping (see figure). Once a "good" cell is identified, a patch clamp can be effected by an automated patchclamping apparatus or by a human operator. This technique has been shown to enable reliable identification of "good" and "bad" candidate cells for patch clamping. The ultimate goal in further development of this technique is to combine artificial-intelligence processing with instrumentation and controls in order to produce a complete "turnkey" automated patch-clamping system capable of accurately and reliably patch clamping cells with a minimum intervention by a human operator. Moreover, this technique can be adapted to virtually any cellular-analysis procedure that includes repetitive operation of microscope hardware by a human.
Chaotic electrical activity of living β-cells in the mouse pancreatic islet
NASA Astrophysics Data System (ADS)
Kanno, Takahiro; Miyano, Takaya; Tokuda, Isao; Galvanovskis, Juris; Wakui, Makoto
2007-02-01
To test for chaotic dynamics of the insulin producing β-cell and explore its biological role, we observed the action potentials with the perforated patch clamp technique, for isolated cells as well as for intact cells of the mouse pancreatic islet. The time series obtained were analyzed using nonlinear diagnostic algorithms associated with the surrogate method. The isolated cells exhibited short-term predictability and visible determinism, in the steady state response to 10 mM glucose, while the intact cells did not. In the latter case, determinism became visible after the application of a gap junction inhibitor. This tendency was enhanced by the stimulation with tolbutamide. Our observations suggest that, thanks to the integration of individual chaotic dynamics via gap junction coupling, the β-cells will lose memory of fluctuations occurring at any instant in their electrical activity more rapidly with time. This is likely to contribute to the functional stability of the islet against uncertain perturbations.
Jung, Christian; Spreiter, Gregor; Audigé, Laurent; Ferguson, Stephen J; Flury, Matthias
2016-05-01
There is an ongoing debate about the potential of patch augmentation to improve biomechanical stability and healing associated with rotator cuff repair. The biomechanical properties of three different patch-augmented rotator cuff repair techniques were assessed in vitro and compared with a standard repair. Dermal collagen patch augmentation may increase the primary stability and strength of the repaired tendon in vitro, depending on the technique used for patch application. Forty cadaveric sheep shoulders with dissected infraspinatus tendons were randomized into four groups (n = 10/group) for tendon repair using a knotless double-row suture anchor technique. A xenologous dermal extracellular matrix patch was used for augmentation in the three test groups using an "integrated", "cover", or "hybrid" technique. Tendons were preconditioned, cyclically loaded from 10 to 30 N at 1 Hz, and then loaded monotonically to failure. Biomechanical properties and the mode of failure were evaluated. Patch augmentation significantly increased the maximum load at failure by 61 % in the "cover" technique test group (225.8 N) and 51 % in the "hybrid" technique test group (211.4 N) compared with the non-augmented control group (140.2 N) (P ≤ 0.015). For the test group with "integrated" patch augmentation, the load at failure was 28 % lower (101.6 N) compared with the control group (P = 0.043). There was no significant difference in initial and linear stiffness among the four experimental groups. The most common mode of failure was tendon pullout. No anchor dislocation, patch disruption or knot breakage was observed. Additional patch augmentation with a collagen patch influences the biomechanical properties of a rotator cuff repair in a cadaveric sheep model. Primary repair stability can be significantly improved depending on the augmentation technique.
New Variable Porosity Flow Diverter (VPOD) Stent Design for Treatment of Cerebrovascular Aneurysms
Ionita, Ciprian; Baier, Robert; Rudin, Stephen
2012-01-01
Using flow diverting Stents for intracranial aneurysm repair has been an area of recent active research. While current commercial flow diverting stents rely on a dense mesh of braided coils for flow diversion, our group has been developing a method to selectively occlude the aneurysm neck, without endangering nearby perforator vessels. In this paper, we present a new method of fabricating the low porosity patch, a key element of such asymmetric vascular stents (AVS). PMID:22254507
[Soft tissue defects treated with perforator flaps].
Weum, Sven; de Weerd, Louis; Klein, Steven; Hage, J Joris
2008-01-31
Treatment of soft tissue defects caused by trauma, tumour surgery or pressure sores is a challenge to the reconstructive surgeon. Although contour and function may be restored by tissue transposition, traditional methods often cause significant donor site morbidity. This article describes how increased understanding of vascular anatomy has led to the development of new techniques. The article is based on textbooks of plastic surgery, selected articles and own clinical experience. Pedicled and free perforator flaps represent the latest development in surgical treatment of soft tissue defects. The use of perforator flaps can considerably reduce the disadvantages that are associated with other surgical methods. The use of perforator flaps demands microsurgical skills, but has many advantages. Reliable vascular supply and a good aesthetical result can be combined with minimal donor site morbidity. In many cases this technique may even give sensibility to the reconstructed area.
Factors associated with postoperative complications and mortality in perforated peptic ulcer.
Montalvo-Javé, Eduardo Esteban; Corres-Sillas, Omar; Athié-Gutiérrez, César
2011-01-01
Elective surgery for uncomplicated peptic ulcer has shown a significant decrease; however, complications such as perforation and obstruction persist and require urgent surgical management. The aim of this study was to identify factors associated with early postoperative complications and mortality of patients admitted to the emergency department with perforated peptic ulcer. We performed a clinical, retrospective, cross-sectional and descriptive study of patients who were treated at the General Hospital of Mexico with a diagnosis of perforated peptic ulcer from January 2006 to December 2008. Thirty patients were included in the study. We studied several clinical findings upon admission to the emergency department and intraoperative patient findings in order to determine the association of those with early postoperative complications and mortality. We studied 30 patients with an average age of 57.07 years (± 14.2 years). The male:female ratio was 2:1. We found that the risk of developing postoperative complications was 66.7% and is significantly influenced by time of onset of abdominal pain prior to admission, bloating, septic shock and blood type O positive. Mortality was 16.7% and was correlated with the presence of septic shock on admission. The surgical procedure performed was primary closure with Graham patch in 86.6%. Average hospital stay was 12.8 days. The presence of early postoperative complications is associated with time of onset of abdominal pain before admission, abdominal distension, blood type O positive and the presence of septic shock on admission.
Kotani, Yoshihisa; Abumi, Kuniyoshi; Ito, Manabu; Takahata, Masahiko; Sudo, Hideki; Ohshima, Shigeki; Minami, Akio
2007-06-15
The accuracy of pedicle screw placement was evaluated in posterior scoliosis surgeries with or without the use of computer-assisted surgical techniques. In this retrospective cohort study, the pedicle screw placement accuracy in posterior scoliosis surgery was compared between conventional fluoroscopic and computer-assisted surgical techniques. There has been no study systemically analyzing the perforation pattern and comparative accuracy of pedicle screw placement in posterior scoliosis surgery. The 45 patients who received posterior correction surgeries were divided into 2 groups: Group C, manual control (25 patients); and Group N, navigation surgery (20 patients). The average Cobb angles were 73.7 degrees and 73.1 degrees before surgery in Group C and Group N, respectively. Using CT images, vertebral rotation, pedicle axes as measured to anteroposterior sacral axis and vertebral axis, and insertion angle error were measured. In perforation cases, the angular tendency, insertion point, and length abnormality were evaluated. The perforation was observed in 11% of Group C and 1.8% in Group N. In Group C, medial perforations of left screws were demonstrated in 8 of 9 perforated screws and 55% were distributed either in L1 or T12. The perforation consistently occurred in pedicles in which those axes approached anteroposterior sacral axis within 5 degrees . The average insertion errors were 8.4 degrees and 5.0 degrees in Group C and Group N, respectively, which were significantly different (P < 0.02). The medial perforation in Group C occurred around L1, especially when pedicle axis approached anteroposterior sacral axis. This consistent tendency was considered as the limitation of fluoroscopic screw insertion in which horizontal vertebral image was not visible. The use of surgical navigation system successfully reduced the perforation rate and insertion angle errors, demonstrating the clear advantage in safe and accurate pedicle screw placement of scoliosis surgery.
Glove perforations during open surgery for gynaecological malignancies.
Manjunath, A P; Shepherd, J H; Barton, D P J; Bridges, J E; Ind, T E J
2008-07-01
To audit glove perforations at laparotomies for gynaecological cancers. Gynaecological oncology unit, cancer centre, London. Prospective audit. Twenty-nine laparotomies for gynaecological cancers over 3 months. Gloves used during laparotomies for gynaecological cancer were tested for perforations by the air inflation and water immersion technique. Parameters recorded were: type of procedure, localisation of perforation, type of gloves, seniority of surgeon, operation time and awareness of perforations. Glove perforation rate. Perforations were found in gloves from 27/29 (93%) laparotomies. The perforation rate was 61/462 (13%) per glove. The perforation rate was three times higher when the duration of surgery was more than 5 hours. The perforation rate was 63% for primary surgeons, 54.5% for first assistant, 4.7% for second assistant and 40.5% for scrub nurses. Clinical fellows were at highest risk of injury (94%). Two-thirds of perforations were on the index finger or thumb. The glove on the nondominant hand had perforations in 54% of cases. In 50% of cases, the participants were not aware of the perforations. There were less inner glove perforations in double gloves compared with single gloves (5/139 versus 26/154; P = 0.0004, OR = 5.4, 95% CI 1.9-16.7). The indicator glove system failed to identify holes in 44% of cases. Glove perforations were found in most (93%) laparotomies for gynaecological malignancies. They are most common among clinical fellows, are often unnoticed and often not detected by the indicator glove system.
Quartararo, N; Barry, P H
1987-12-01
A technical problem associated with the patch clamp technique has been the changing of solutions bathing the membrane patch. The simple technique described here solves this problem by means of a movable polythene sleeve placed on the shaft of the patch clamp pipette. The sleeve is initially placed so that the tip of the pipette is exposed. A gigaohm seal is formed using standard techniques. The patch is then excised and the sleeve is slipped down a few mm past the end of the tip of the pipette. When the pipette and sleeve is now removed from the solution, a small drop of solution covering the membrane patch is held in place at the end of the sleeve by surface tension. The pipette is then easily transferred to a different solution without passing the membrane patch through the air-water interface. The sleeve is then simply pulled back up the pipette shaft to expose the membrane patch to the new solution.
Endoscopic closure of septal perforations.
Alobid, Isam
The management of septal perforations is a challenge for the surgeon. A wide variety of surgical techniques have been described, with different approaches. There is no scientific evidence to support a particular approach. The objective of this review is to present a practical guide on the technique of choice for each case of septal perforation. Inspection of the nasal mucosa, the size of the perforation, the location and especially the osteo-cartilaginous support, are the pillars of a successful surgery. For the sliding or rotating flaps of the mucosa of the septum it is essential to know in advance if the elevation of the mucopericondrio or mucoperiosteo of the septum is possible, otherwise the use of these flaps would not be indicated. The flaps of the lateral wall or nasal floor are the alternative. The pericranial flap may be indicated in total or near total perforations. The remnant of the nasal septum and status of osteo-cartilaginous support are the determining factors in the management of septal perforations. Each case should be evaluated individually and the approach chosen according to the size and location of the perforation, mucosal quality, personal history, previous surgery and the experience of the surgeon. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.
Kim, Youn Hwan; Kim, Sang Wha; Kim, Jeong Tae; Kim, Chang Yeon
2013-06-01
Tensor fascia lata (TFL) musculocutaneous flaps often require a donor site graft when harvesting a large flap. However, a major drawback is that it also sacrifices the muscle. To overcome this disadvantage, we designed a TFL perforator-based island flap that was harvested from a site near the defect and involved transposition within 90 degrees without full isolation of the pedicles. We performed procedures on 17 musculocutaneous flaps and 23 perforator-based island flaps, and compared the outcomes of these surgeries. The overall complication rate was 27.5% (11 regions). There were 7 complications related to the musculocutaneous flaps and 4 complications related to the perforator flaps. Although there were no statistical differences between those groups, lower complication rates were associated with procedures involving perforator flaps. The TFL perforator procedure is a simple and fast operation that avoids sacrificing muscle. This decreases complication rates compared to true perforator flap techniques that require dissection around the perforator or pedicle.
Pre-expanded Intercostal Perforator Super-Thin Skin Flap.
Liao, Yunjun; Luo, Yong; Lu, Feng; Hyakusoku, Hiko; Gao, Jianhua; Jiang, Ping
2017-01-01
This article introduces pre-expanded super-thin intercostal perforator flaps, particularly the flap that has a perforator from the first to second intercostal spaces. The key techniques, advantages and disadvantages, and complications and management of this flap are described. At present, the thinnest possible flap is achieved by thinning the pre-expanded flap that has a perforator from the first to second intercostal spaces. It is used to reconstruct large defects on the face and neck, thus restoring function and cosmetic appearance. Copyright © 2016 Elsevier Inc. All rights reserved.
Stercoral perforation of the colon proximal to an end colostomy.
Serpell, J. W.; Sen, M.; Giddins, G.; Nicholls, R. J.; Bradfield, W. J.
1991-01-01
Stercoral perforation of the colon is rare, and has not previously been reported as a postoperative complication, proximal to an end colostomy. Two such cases are reported; in addition in one the stercoral perforation was recurrent, emphasizing the multifocal nature of the disease. Both cases demonstrate the failure of standard techniques to deal with scybala in the loaded proximal colon. It is, therefore, suggested that intra-operative orthograde colonic lavage is indicated to protect a terminal colostomy from the risk of stercoral perforation in such cases. PMID:2062783
The Sixth Decision Regarding Perforated Duodenal Ulcer
McMahon, Ross L.; Kakihara, Minoru; Pappas, Theodore N.; Eubanks, Steve
2002-01-01
This presentation reviews the literature regarding the current surgical treatment of perforated ulcers, describes the surgical techniques for laparoscopic repair, and reviews the clinical algorithm used by laparoscopic surgeons at Duke University Medical Center. PMID:12500837
Chiu, Chee Kidd; Chan, Chris Yin Wei; Kwan, Mun Keong
2017-01-01
This study investigates the safety and accuracy of percutaneous pedicle screws placed using fluoroscopic guidance in the thoracolumbosacral spine among Asian patients. Computerized tomography scans of 128 patients who had surgery using fluoroscopic-guided percutaneous pedicle screws were selected. Medial, lateral, superior, and inferior screw perforations were classified into grade 0 (no violation), grade 1 (<2 mm perforation), grade 2 (2-4 mm perforation), and grade 3(>4 mm perforation). Anterior perforations were classified into grade 0 (no violation), grade 1 (<4 mm perforation), grade 2 (4-6 mm perforation), and grade 3(>6 mm perforation). Grade 2 and grade 3 perforation were considered as "critical" perforation. In total, 1002 percutaneous pedicle screws from 128 patients were analyzed. The mean age was 52.7 ± 16.6. There were 70 male patients and 58 female patients. The total perforation rate was 11.3% (113) with 8.4% (84) grade 1, 2.6% (26) grade 2, and 0.3% (3) grade 3 perforations. The overall "critical" perforation rate was 2.9% (29 screws) and no complications were noted. The highest perforation rates were at T4 (21.6%), T2 (19.4%), and T6 (19.2%). The total perforation rate of 11.3% with the total "critical" perforation rate of 2.9% (2.6% grade 2 and 0.3% grade 3 perforations). The highest perforation rates were found over the upper to mid-thoracic region. Fluoroscopic-guided percutaneous pedicle screws insertion among Asians has the safety and accuracy comparable to the current reported percutaneous pedicle screws and open pedicle screws techniques.
Material development for laminar flow control wing panels
NASA Technical Reports Server (NTRS)
Meade, L. E.
1977-01-01
The absence of suitable porous materials or techniques for the economic perforation of surface materials has previously restricted the design of laminar flow control (LFC) wing panels to a consideration of mechanically slotted LFC surfaces. A description is presented of a program which has been conducted to exploit recent advances in materials and manufacturing technology for the fabrication of reliable porous or perforated LFC surface panels compatible with the requirements of subsonic transport aircraft. Attention is given to LFC design criteria, surface materials, surface concepts, the use of microporous composites, perforated composites, and perforated metal. The described program was successful in that fabrication processes were developed for producing predictable perforated panels both of composite and of metal.
Complex role of STIM1 in the activation of store-independent Orai1/3 channels
Zhang, Wei; González-Cobos, José C.; Jardin, Isaac; Romanin, Christoph; Matrougui, Khalid
2014-01-01
Orai proteins contribute to Ca2+ entry into cells through both store-dependent, Ca2+ release–activated Ca2+ (CRAC) channels (Orai1) and store-independent, arachidonic acid (AA)-regulated Ca2+ (ARC) and leukotriene C4 (LTC4)-regulated Ca2+ (LRC) channels (Orai1/3 heteromultimers). Although activated by fundamentally different mechanisms, CRAC channels, like ARC and LRC channels, require stromal interacting molecule 1 (STIM1). The role of endoplasmic reticulum–resident STIM1 (ER-STIM1) in CRAC channel activation is widely accepted. Although ER-STIM1 is necessary and sufficient for LRC channel activation in vascular smooth muscle cells (VSMCs), the minor pool of STIM1 located at the plasma membrane (PM-STIM1) is necessary for ARC channel activation in HEK293 cells. To determine whether ARC and LRC conductances are mediated by the same or different populations of STIM1, Orai1, and Orai3 proteins, we used whole-cell and perforated patch-clamp recording to compare AA- and LTC4-activated currents in VSMCs and HEK293 cells. We found that both cell types show indistinguishable nonadditive LTC4- and AA-activated currents that require both Orai1 and Orai3, suggesting that both conductances are mediated by the same channel. Experiments using a nonmetabolizable form of AA or an inhibitor of 5-lipooxygenase suggested that ARC and LRC currents in both cell types could be activated by either LTC4 or AA, with LTC4 being more potent. Although PM-STIM1 was required for current activation by LTC4 and AA under whole-cell patch-clamp recordings in both cell types, ER-STIM1 was sufficient with perforated patch recordings. These results demonstrate that ARC and LRC currents are mediated by the same cellular populations of STIM1, Orai1, and Orai3, and suggest a complex role for both ER-STIM1 and PM-STIM1 in regulating these store-independent Orai1/3 channels. PMID:24567509
Effect of an N-terminus deletion on voltage-dependent gating of the ClC-2 chloride channel
Varela, Diego; Niemeyer, María Isabel; Cid, L Pablo; Sepúlveda, Francisco V
2002-01-01
ClC-2, a chloride channel widely expressed in mammalian tissues, is activated by hyperpolarisation and extracellular acidification. Deletion of amino acids 16–61 in rat ClC-2 abolishes voltage and pH dependence in two-electrode voltage-clamp experiments in amphibian oocytes. These results have been interpreted in terms of a ball-and-chain type of mechanism in which the N-terminus would behave as a ball that is removed from an inactivating site upon hyperpolarisation. We now report whole-cell patch-clamp measurements in mammalian cells showing hyperpolarization-activation of rClC-2Δ16–61 differing only in presenting faster opening and closing kinetics than rClC-2. The lack of time and voltage dependence observed previously was reproduced, however, in nystatin-perforated patch experiments. The behaviour of wild-type rClC-2 did not differ between conventional and nystatin-perforated patches. Similar results were obtained with ClC-2 from guinea-pig. One possible explanation of the results is that some diffusible component is able to lock the channel in an open state but does so only to the mutated channel. Alternative explanations involving the osmotic state of the cell and cytoskeleton structure are also considered. Low extracellular pH activates the wild-type channel but not rClC-2Δ16–61 when expressed in oocytes, a result that had been interpreted to suggest that protons affect the ball-and-chain mechanism. In our experiments no difference was seen in the effect of extracellular pH upon rClC-2 and rClC-2Δ16–61 in either recording configuration, suggesting that protons act independently from possible effects of the N-terminus on gating. Our observations of voltage-dependent gating of the N-terminal deleted ClC-2 are an argument against a ball-and-chain mechanism for this channel. PMID:12381811
Duchen, M R; Smith, P A; Ashcroft, F M
1993-08-15
Microfluorimetric and patch-clamp techniques have been combined to determine the relationship between changes in mitochondrial metabolism, the activity of KATP channels and changes in intracellular free calcium concentration ([Ca2+]i) in isolated pancreatic beta-cells in response to glucose, ketoisocaproic acid (KIC) and the electron donor couple tetramethyl p-phenylenediamine (TMPD) and ascorbate. Exposure of cells to 20 mM glucose raised NAD(P)H autofluorescence after a delay of 28 +/- 1 s (mean +/- S.E.M., n = 30). The mitochondrial inner membrane potential, delta psi m (monitored using rhodamine 123 fluorescence), hyperpolarized with a latency of 49 +/- 6 s (n = 17), and the [Ca2+]i rose after 129 +/- 13 s (n = 5). The amplitudes of the metabolic changes were graded appropriately with glucose concentration over the range 2.5-20 mM. All variables responded to KIC with shorter latencies: NAD(P)H autofluorescence rose after a delay of 20 +/- 3 s (n = 5) and rhodamine 123 changed after 21 +/- 3 s (n = 6). The electron donor couple, TMPD with ascorbate, rapidly hyperpolarized delta psi m and raised [Ca2+]i. When [Ca2+]i was raised by sustained exposure to 20 mM glucose, TMPD had no further effect. TMPD also decreased whole-cell KATP currents and depolarized the cell membrane, measured with the perforated patch configuration. These data are consistent with a central role for mitochondrial oxidative phosphorylation in coupling changes in glucose concentration with the secretion of insulin.
Role of over the scope clips in the management of iatrogenic gastrointestinal perforations
Changela, Kinesh; Virk, Muhhamad A; Patel, Niravkumar; Duddempudi, Sushil; Krishnaiah, Mahesh; Anand, Sury
2014-01-01
Advances in endoscopic and surgical techniques have increased the frequency and complexity of these procedures and associated complications such as gastrointestinal perforation. With the advancements in the field of gastroenterology, the promising use of an over the scope clips (OTSC) has fulfilled the unmet need for a reliable endoscopic devise in approximation of gastrointestinal perforation. This novel approach has raised the level of confidence in endoscopist in dealing with this serious complication during endoscopy. Here we have shared our experience with OTSC to evaluate its efficacy and safety in managing iatrogenic gastrointestinal perforations during endoscopy. PMID:25170237
Role of over the scope clips in the management of iatrogenic gastrointestinal perforations.
Changela, Kinesh; Virk, Muhhamad A; Patel, Niravkumar; Duddempudi, Sushil; Krishnaiah, Mahesh; Anand, Sury
2014-08-28
Advances in endoscopic and surgical techniques have increased the frequency and complexity of these procedures and associated complications such as gastrointestinal perforation. With the advancements in the field of gastroenterology, the promising use of an over the scope clips (OTSC) has fulfilled the unmet need for a reliable endoscopic devise in approximation of gastrointestinal perforation. This novel approach has raised the level of confidence in endoscopist in dealing with this serious complication during endoscopy. Here we have shared our experience with OTSC to evaluate its efficacy and safety in managing iatrogenic gastrointestinal perforations during endoscopy.
Outside-out "sniffer-patch" clamp technique for in situ measures of neurotransmitter release.
Muller-Chrétien, Emilie
2014-01-01
The mechanism underlying neurotransmitter release is a critical research domain for the understanding of neuronal network function; however, few techniques are available for the direct detection and measurement of neurotransmitter release. To date, the sniffer-patch clamp technique is mainly used to investigate these mechanisms from individual cultured cells. In this study, we propose to adapt the sniffer-patch clamp technique to in situ detection of neurosecretion. Using outside-out patches from donor cells as specific biosensors plunged in acute cerebral slices, this technique allows for proper detection and quantification of neurotransmitter release at the level of the neuronal network.
Application of Layered Perforation Profile Control Technique to Low Permeable Reservoir
NASA Astrophysics Data System (ADS)
Wei, Sun
2018-01-01
it is difficult to satisfy the demand of profile control of complex well section and multi-layer reservoir by adopting the conventional profile control technology, therefore, a research is conducted on adjusting the injection production profile with layered perforating parameters optimization. i.e. in the case of coproduction for multi-layer, water absorption of each layer is adjusted by adjusting the perforating parameters, thus to balance the injection production profile of the whole well section, and ultimately enhance the oil displacement efficiency of water flooding. By applying the relationship between oil-water phase percolation theory/perforating damage and capacity, a mathematic model of adjusting the injection production profile with layered perforating parameters optimization, besides, perforating parameters optimization software is programmed. Different types of optimization design work are carried out according to different geological conditions and construction purposes by using the perforating optimization design software; furthermore, an application test is done for low permeable reservoir, and the water injection profile tends to be balanced significantly after perforation with optimized parameters, thereby getting a good application effect on site.
Wang, Yingsong; Xie, Jingming; Yang, Zhendong; Zhao, Zhi; Zhang, Ying; Li, Tao; Liu, Luping
2013-07-01
To present the technique of free-hand subaxial cervical pedicle screw (CPS) placement without using intra-operative navigating devices, and to investigate the crucial factors for safe placement and avoidance of lateral pedicle wall perforation, by measuring and classifying perforations with postoperative computed tomography (CT) scan. The placement of CPS has generally been considered as technically demanding and associated with considerable lateral wall perforation rate. For surgeons without access to navigation systems, experience of safe free-hand technique for subaxial CPS placement is especially valuable. A total of 214 consecutive traumatic or degenerative patients with 1,024 CPS placement using the free-hand technique were enrolled. In the operative process, the lateral mass surface was decorticated. Then a small curette was used to identify the pedicle entrance by touching the cortical bone of the medial pedicle wall. It was crucial to keep the transverse angle and make appropriate adjustment with guidance of the resistance of the thick medial cortical bone. The hand drill should be redirected once soft tissue breach was palpated by a slim ball-tip prober. With proper trajectory, tapping, repeated palpation, the 26-30 mm screw could be placed. After the procedure, the transverse angle of CPS trajectory was measured, and perforation of the lateral wall was classified by CT scan: grade 1, perforation of pedicle wall by screw placement, with the external edge of screw deviating out of the lateral pedicle wall equal to or less than 2 mm and grade 2, critical perforation of pedicle wall by screw placement, large than 2 mm. A total of 129 screws (12.64 %) were demonstrated as lateral pedicle wall perforation, of which 101 screws (9.86 %) were classified as grade 1, whereas 28 screws (2.73 %) as grade 2. Among the segments involved, C3 showed an obviously higher perforating rate than other (P < 0.05). The difference between the anatomical pedicle transverse angle and the screw trajectory angle was higher in patients of grade 2 perforation than the others. In the 28 screws of grade 2 perforation verified by axial CT, 26 screws had been palpated as abnormal during operation. However, only 19 out of the 101 screws of grade 1 perforation had shown palpation alarming signs during operation. The average follow-up was 36.8 months (range 5-65 months). There was no symptom and sign of neurovascular injuries. Two screws (0.20 %) were broken, and one screw (0.10 %) loosen. Placement of screw through a correct trajectory may lead to grade 1 perforation, which suggests transversal expansion and breakage of the thinner lateral cortex, probably caused by mismatching of the diameter of 3.5 mm screws and the tiny cancellous bone cavity of pedicle. Grade 1 perforation is deemed as relatively safe to the vertebral artery. Grade 2 perforation means obvious deviation of the trajectory angle of hand drill, which directly penetrates into the transverse foramen, and the risk of vertebral artery injury (VAI) or development of thrombi caused by the irregular blood flow would be much greater compared to grade 1 perforation. Moreover, there are two crucial maneuvers for increasing accuracy of screw placement: identifying the precise entry point using a curette or hand drill to touch the true entrance of the canal after decortication, and guiding CPS trajectory on axial plane by the resistant of thick medial wall.
Laparoscopic repair of perforated peptic duodenal ulcer.
Busić, Zeljko; Servis, Draien; Slisurić, Ferdinand; Kristek, Jozo; Kolovrat, Marijan; Cavka, Vlatka; Cavka, Mislav; Cupurdija, Kristijan; Patrlj, Leonardo; Kvesić, Ante
2010-03-01
Although prevalence of peptic ulcer is decreasing, the number of peptic ulcer perforations appears to be unchanged. This complication of peptic ulcer is traditionally surgically treated. In recent years, a number of papers have been published where the authors managed perforated duodenal peptic ulcer in selected patients using laparoscopic approach. Laparoscopic treatment of perforated duodenal ulcer has been described as safe and advantageous compared to open technique but advantages are still not clear due to small number of cases in published studies. Based on these recommendations we decided to establish our own protocol for laparoscopic treatment of perforated peptic duodenal ulcer. In this prospective study we evaluated the first 10 patients in whom we performed laparoscopic repair of perforated duodenal ulcer. There were no conversions to open procedure and no early postoperative complications. The patients were contacted by phone a year after the operation, and all were satisfied with the operation and the appearance of postoperative scars. We regard laparoscopic repair of selected patients with perforated duodenal ulcer as a safe and preferable treatment.
Pauly, Stephan; Fiebig, David; Kieser, Bettina; Albrecht, Bjoern; Schill, Alexander; Scheibel, Markus
2011-12-01
Biomechanical comparison of four different Speed-Bridge configurations with or without medial or lateral row reinforcement. Reinforcement of the knotless Speed-Bridge double-row repair technique with additional medial mattress- or lateral single-stitches was hypothesized to improve biomechanical repair stability at time zero. Controlled laboratory study: In 36 porcine fresh-frozen shoulders, the infraspinatus tendons were dissected and shoulders were randomized to four groups: (1) Speed-Bridge technique with single tendon perforation per anchor (STP); (2) Speed-Bridge technique with double tendon perforation per anchor (DTP); (3) Speed-Bridge technique with medial mattress-stitch reinforcement (MMS); (4) Speed-Bridge technique with lateral single-stitch reinforcement (LSS). All repairs were cyclically loaded from 10-60 N up to 10-200 N (20 N stepwise increase) using a material testing device. Forces at 3 and 5 mm gap formation, mode of failure and maximum load to failure were recorded. The MMS-technique with double tendon perforation showed significantly higher ultimate tensile strength (338.9 ± 90.0 N) than DTP (228.3 ± 99.9 N), LSS (188.9 ± 62.5 N) and STP-technique (122.2 ± 33.8 N). Furthermore, the MMS-technique provided increased maximal force resistance until 3 and 5 mm gap formation (3 mm: 77.8 ± 18.6 N; 5 mm: 113.3 ± 36.1 N) compared with LSS, DTP and STP (P < 0.05 for each 3 and 5 mm gap formation). Failure mode was medial row defect by tendon sawing first, then laterally. No anchor pullout occurred. Double tendon perforation per anchor and additional medial mattress stitches significantly enhance biomechanical construct stability at time zero in this ex vivo model when compared with the all-knotless Speed-Bridge rotator cuff repair.
Evaluation of concrete pavement patching techniques.
DOT National Transportation Integrated Search
1989-01-01
This final report presents the results of a study undertaken to improve in concrete pavement patching techniques. Activities included an evaluation of the suitability of the impact hammer and maturity calculations for determining when a patch is read...
Struk, S; Schaff, J-B; Qassemyar, Q
2018-04-01
The medial sural artery perforator (MSAP) flap is defined as a thin cutaneo-adipose perforator flap harvested on the medial aspect of the leg. The aims of this study were to describe the anatomical basis as well as the surgical technique and discuss the indications in head and neck reconstructive surgery. We harvested 10 MSAP flap on 5 fresh cadavers. For each case, the number and the location of the perforators were recorded. For each flap, the length of pedicle, the diameter of source vessels and the thickness of the flap were studied. Finally, we performed a clinical application of a MSAP flap. A total of 23 perforators with a diameter superior than 1mm were dissected on 10 legs. The medial sural artery provided between 1 and 4 musculocutaneous perforators. Perforators were located in average at 10.3cm±2cm from the popliteal fossa and at 3.6cm±1cm from the median line of the calf. The mean pedicle length was 12.1cm±2.5cm. At its origin, the source artery diameter was 1.8mm±0.25mm and source veins diameters were 2.45mm±0.9mm in average. There was no complication in our clinical application. This study confirms the reliability of previous anatomical descriptions of the medial sural artery perforator flap. This flap was reported as thin and particularly adapted for oral cavity reconstruction and for facial or limb resurfacing. Sequelae might be reduced as compared to those of the radial forearm flap with comparable results. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Boon Tow, Benjamin Phak; Yue, Wai Mun; Srivastava, Abhishek; Lai, Jenn Ming; Guo, Chang Ming; Wearn Peng, Benedict Chan; Chen, John L T; Yew, Andy K S; Seng, Chusheng; Tan, Seang Beng
2015-10-01
This was a prospective, nonrandomized study. To assess the accuracy of O-arm navigation-based pedicle screw insertion in lumbar degenerative spondylolisthesis and to compare it with free-hand pedicle screw insertion technique in matched population. O-arm navigation is latest in navigation technology that can provide real-time intraoperative images in 3 dimensions while placing the pedicle screws to improve intraoperative pedicle screw accuracy. Degenerative lumbar spondylolisthesis is a locally unstable pathology and placement of pedicle screws can cause increased rotation and translation of the vertebral body. However, is this motion detected by the tracker placed across the unstable segment, is a matter of debate. Inability to detect these positional changes can lead to pedicle perforation while inserting screws using navigation. No study has evaluated the role of O-arm navigation in this patient population. The study population was divided into 2 groups with 19 patients each, one comprising patients who underwent O-arm navigation-based pedicle screw insertion (group 1) and the other comprising patients who underwent free-hand pedicle screw insertion technique (group 2). A total of 152 pedicle screws were implanted in 38 patients for 1-level instrumented fusion for degenerative lumbar spondylolisthesis. Intraoperative 3-dimensional computed tomography scans using the O-arm were obtained for all patients after insertion of pedicle screws. The images were reviewed intraoperatively and postoperatively for the analysis of pedicle breaches. Assessments in either of the group included (i) accuracy of placement of screws; (ii) the rate and direction of perforation; and (iii) the number of segments the perforated screw was away from the navigation tracker. Mean age of patients in group 1 (O-arm navigation-assisted) was 60 years (SD 11.25; range, 37-73 y), whereas in group 2 (free-hand pedicle screw) was 62 years (SD 18.07; range, 36-90 y). Overall anatomic perforation rate was 12.5% (19/152). Individually, group 1 had 14.47% (11/76) of perforations in comparison with 10.53% (8/76) observed in group 2. The difference was not statistically significant. The lateral margin was the most common site of perforation in both group 1 (64%, 7/11) and group 2 (62.5%, 5/8). Functional perforation rate for the series was 3.3% (5/152), with group 1 having 2.63% (2/76) and group 2 having 3.95% (3/76). The rate of perforation (PR) was significantly higher statistically when the tracker was placed 3 or more [PR 37.5% (6/16)] spinal segments away from instrumented segment compared with when it was placed 1 (0%) or 2 [PR 13.89% (5/36)] spinal segments away. Overall, 11 screws (11/152, 7.24%) had grade 2 perforations and had to be revised. No neurological complications were observed in the series. O-arm navigation does not provide any significant advantage over conventional free-hand pedicle screw insertion technique in patients with single-level degenerative spondylolisthesis. The accuracy is dependent on the distance of the tracker from the level of instrumentation. Lateral perforations are more common because of instability at the instrumented level leading to translation and rotation of the vertebral body while placing pedicle screws leading to preferential lateral trajectory. These lateral perforations could not be prevented by using navigation. However, no significant complications were noted in either technique.
Practical issues in the implementation of electro-mechanical impedance technique for NDE
NASA Astrophysics Data System (ADS)
Bhalla, Suresh; Naidu, Akshay S. K.; Ong, Chin W.; Soh, Chee-Kiong
2002-11-01
The electro-mechanical impedance (EMI) technique, which utilizes "smart" piezoceramic (PZT) patches as collocated actuator-sensors, has recently emerged as a powerful technique for diagnosing incipient damages in structures and machines. This technique utilizes the electro-mechanical admittance of a PZT patch surface bonded to the structure as the diagnostic signature of the structure. The operating frequency is typically maintained in the kHz range for optimum sensitivity in damage detection. However, there are many impediments to the practical application of the technique for NDE of real-life structures, such as aerospace systems, machine parts, and civil-infrastructures like buildings and bridges. The main challenge lies in achieving consistent behavior of the bonded PZT patch over sufficiently long periods, typically of the order of years, under "harsh" environment. This necessitates protecting the PZT patch from environmental effects. This paper reports a dedicated investigation stretched over several months to ascertain the long-term consistency of the electro-mechanical admittance signatures of PZT patches. Possible protection of the patch by means of suitable covering layer as well as the effects of the layer on damage sensitivity of the patch are also investigated. It is found that a suitable cover is necessary to protect the PZT patch, especially against humidity and to ensure long life. It is also found that the patch exhibits a high sensitivity to damage even in the presence of the protection layer. The paper also includes a brief discussion on few recent applications of the EMI technique and possible use of multiplexing to optimize sensor interrogation time.
Yajuan, Xiao; Xin, Liang; Zhiyuan, Li
2012-01-01
The patch clamp technique is commonly used in electrophysiological experiments and offers direct insight into ion channel properties through the characterization of ion channel activity. This technique can be used to elucidate the interaction between a drug and a specific ion channel at different conformational states to understand the ion channel modulators’ mechanisms. The patch clamp technique is regarded as a gold standard for ion channel research; however, it suffers from low throughput and high personnel costs. In the last decade, the development of several automated electrophysiology platforms has greatly increased the screen throughput of whole cell electrophysiological recordings. New advancements in the automated patch clamp systems have aimed to provide high data quality, high content, and high throughput. However, due to the limitations noted above, automated patch clamp systems are not capable of replacing manual patch clamp systems in ion channel research. While automated patch clamp systems are useful for screening large amounts of compounds in cell lines that stably express high levels of ion channels, the manual patch clamp technique is still necessary for studying ion channel properties in some research areas and for specific cell types, including primary cells that have mixed cell types and differentiated cells that derive from induced pluripotent stem cells (iPSCs) or embryonic stem cells (ESCs). Therefore, further improvements in flexibility with regard to cell types and data quality will broaden the applications of the automated patch clamp systems in both academia and industry. PMID:23346269
Jiang, Taoran; Zhu, Ming; Zan, Tao; Gu, Bin; Li, Qingfeng
2017-08-01
In perforator flap transplantation, dissection of the perforator is an important but difficult procedure because of the high variability in vascular anatomy. Preoperative imaging techniques could provide substantial information about vascular anatomy; however, it cannot provide direct guidance for surgeons during the operation. In this study, a navigation system (NS) was established to overlie a vascular map on surgical sites to further provide a direct guide for perforator flap transplantation. The NS was established based on computed tomographic angiography and augmented reality techniques. A virtual vascular map was reconstructed according to computed tomographic angiography data and projected onto real patient images using ARToolKit software. Additionally, a screw-fixation marker holder was created to facilitate registration. With the use of a tracking and display system, we conducted the NS on an animal model and measured the system error on a rapid prototyping model. The NS assistance allowed for correct identification, as well as a safe and precise dissection of the perforator. The mean value of the system error was determined to be 3.474 ± 1.546 mm. Augmented reality-based NS can provide precise navigation information by directly displaying a 3-dimensional individual anatomical virtual model onto the operative field in real time. It will allow rapid identification and safe dissection of a perforator in free flap transplantation surgery.
[Comparison of 2 lacrimal punctal occlusion methods].
Shalaby, O; Rivas, L; Rivas, A I; Oroza, M A; Murube, J
2001-09-01
To study and compare two methods for canalicular occlusion: Cautery and Punctal Patch. The study included fourty patients divided in two groups of 20 patients. The end point was 4 occluded puncti. The first group underwent deep cauterization resulting in occlusion of the full vertical aspect of the canaliculus. The second group underwent punctal patch technique for canalicular occlusion. Differential parameters were the following: time of intervention, ease of use, risks and precision. In the post operatory, discomfort, subjective and objective improvement in ocular surface as well as long term result of each technique was analysed. Time of intervention was longer for punctal patch compared to cautery. Both methods exhibited similar ease of use and improvement in ocular surface. Precision was high in punctal patch technique showing complete and final occlusion and no punctum needed reopening, while cautery technique presented 20% rate of reopening intervention. Postoperatory discomfort and irritation were remarkably evident with punctal technique, while minimal in cautery technique. Survival analysis after one year follow up, showed a higher rate of advantages for punctal patch technique over cautery technique.
Shelat, Vishal G; Ahmed, Saleem; Chia, Clement L K; Cheah, Yee Lee
2015-02-01
Application of minimal access surgery in acute care surgery is limited due to various reasons. Laparoscopic omental patch repair (LOPR) for perforated peptic ulcer (PPU) surgery is safe and feasible but not widely implemented. We report our early experience of LOPR with emphasis on strict selection criteria. This is a descriptive study of all patients operated on for PPU at academic university-affiliated institutes from December 2010 to February 2012. All the patients who were operated on for LOPR were included as the study population and their records were studied. Perioperative outcomes, Boey score, Mannheim Peritonitis Index (MPI), and physiologic and operative severity scores for enumeration of mortality and morbidity (POSSUM) scores were calculated. All the data were tabulated in a Microsoft Excel spreadsheet and analyzed using Stata Version 8.x. (StataCorp, College Station, TX, USA). Fourteen patients had LOPR out of a total of 45 patients operated for the PPU. Mean age was 46 years (range 22-87 years). Twelve patients (86%) had a Boey score of 0 and all patients had MPI < 21 (mean MPI = 14). The predicted POSSUM morbidity and mortality were 36% and 7%, respectively. Mean ulcer size was 5 mm (range 2-10 mm), mean operating time was 100 minutes (range 70-123 minutes) and mean length of hospital stay was 4 days (range 3-6 days). There was no morbidity or mortality pertaining to LOPR. LOPR should be offered by acute care surgical teams when local expertise is available. This can optimize patient outcomes when strict selection criteria are applied.
Zhu, Yaohui; Huizinga, Jan D
2008-01-01
Abstract Nitrergic nerves are structurally and functionally associated with ICC. To further understand mechanisms of communication, the hypothesis was investigated that NO might affect large conductance K channels. To that end, we searched for IbTX-sensitive currents in ICC obtained through explant cultures from the mouse small intestine and studied effects of the NOS inhibitor omega N-nitro-L-arginine (LNNA) and the NO donor sodium nitroprusside (SNP). IbTX-sensitive currents acquired in the whole-cell configuration through nystatin perforated patches exhibited high noise levels but relatively low amplitude, whereas currents obtained in the conventional whole-cell configuration exhibited less noise and higher amplitudes; depolarization from −80 to + 40 mV evoked 357 ± 159 pA current in the nystatin perforated patch configuration and 1075 ± 597 pA using the conventional whole-cell configuration. Immunohistochemistry showed that ICC associated with ganglia and Auerbach's plexus nerve fibers were immunoreactive to BK antibodies. The IbTX-sensitive currents were increased by SNP and inhibited by LNNA. BK blockers suppressed spontaneous transit outward currents in ICC. After block of BK currents, or before these currents became prominent, calcium currents were activated by depolarization in the same cells. Their peak amplitude occurred at −25 mV and the currents were increased with increasing extracellular calcium and inhibited by cobalt. The hypothesis is warranted that nitrergic innervation inhibits ICC excitability in part through activation of BK channels. In addition, NO is an intracellular regulator of ICC excitability. PMID:18194464
Sharma, Smita S; Mamtani, Manju R; Sharma, Mamta S; Kulkarni, Hemant
2006-06-16
With dwindling rates of postoperative mortality in perforated peptic ulcer that is attributable to H2-receptor blocker usage, there is a need to shift the focus towards the prevention of postoperative morbidity. Further, the simultaneous contribution of several putative clinical predictors to this postoperative morbidity is not fully appreciated. Our objective was to assess the predictors of the risk, rate and number of postoperative complications in surgically treated patients of perforated peptic ulcer. In a prospective cohort study of 96 subjects presenting as perforated peptic ulcer and treated using Graham's omentoplatsy patch or gastrojejunostomy (with total truncal vagotomy), we assessed the association of clinical predictors with three domains of postoperative complications: the risk of developing a complication, the rate of developing the first complication and the risk of developing higher number of complications. We used multiple regression methods - logistic regression, Cox proportional hazards regression and Poisson regression, respectively - to examine the association of the predictors with these three domains. We observed that the risk of developing a postoperative complication was significantly influenced by the presence of a concomitant medical illness [odds ratio (OR) = 8.9, p = 0.001], abdominal distension (3.8, 0.048) and a need of blood transfusion (OR = 8.2, p = 0.027). Using Poisson regression, it was observed that the risk for a higher number of complications was influenced by the same three factors [relative risk (RR) = 2.6, p = 0.015; RR = 4.6, p < 0.001; and RR = 2.4, p = 0.002; respectively]. However, the rate of development of complications was influenced by a history suggestive of shock [relative hazards (RH) = 3.4, p = 0.002] and A- blood group (RH = 4.7, p = 0.04). Abdominal distension, presence of a concomitant medical illness and a history suggestive of shock at the time of admission warrant a closer and alacritous postoperative management in patients of perforated peptic ulcer.
Laparoscopic repair of perforated peptic ulcer: single-center results.
Guadagni, Simone; Cengeli, Ismail; Galatioto, Christian; Furbetta, Niccolò; Piero, Vincenzo Lippolis; Zocco, Giuseppe; Seccia, Massimo
2014-08-01
Perforated peptic ulcer (PPU), the most common indication for emergency gastric surgery, is associated with high morbidity and mortality rates. Outcomes might be improved by performing this procedure laparoscopically, but no consensus exists on whether the benefits of laparoscopic repair (LR) of PPU outweigh the disadvantages. From January 2002 to December 2012, 111 patients underwent surgery for perforated ulcer. A "laparoscopy-first" policy was attempted and then applied for 56 patients. The exclusion criteria for LR ruled out patients who had shock at admission, severe cardiorespiratory comorbidities, or a history of supramesocolic surgery. The aim of this study was a retrospective analysis of the 56 patients treated laparoscopically. The patient distribution was 30 men and 26 women, who had a mean age of 59 years (range 19-95 years). The mean ulcer size was 10 mm, and the Mannheim peritonitis index (MPI) was 21. LR was performed for 39 (69.6%) of the 56 patients and included peritoneal lavage, suturing of the perforation, and omental patching. Conversion to laparotomy was necessary in 17 cases (30.4%). The "conversion group" showed significant differences in ulcer size (larger ulcers: 1.9 vs. 0.7 mm; p < 0.01), ulcer-site topography (higher incidence of posterior ulcers: 5 vs. 0; p < 0.01), and MPI score (higher score: 24 vs. 20; p < 0.05). The LR group had a mean operating time of 86 min (range 50-125 min), an in-hospital morbidity rate of 7.6 %, a mortality rate of 2.5%, and a mean hospital stay of 6.7 days (range 5-12 days). None of these patients required reintervention. The results showed that LR for PPU is feasible with acceptable mortality and morbidity rates. Skill in laparoscopic abdominal emergencies is required. Perforations 1.5 cm or larger, posterior duodenal ulcers, and an MPI higher than 25 should be considered the main risk factors for conversion.
NASA Astrophysics Data System (ADS)
Molinario, G.; Hansen, M. C.; Potapov, P. V.
2015-09-01
Shifting cultivation has traditionally been practiced in the Democratic Republic of Congo by carving agricultural fields out of primary and secondary forest, resulting in the rural complex: a characteristic land cover mosaic of roads, villages, active and fallow fields and secondary forest. Forest clearing has varying impacts depending on where it occurs relative to this area: whether inside it, along its primary forest interface, or in more isolated primary forest areas. The spatial contextualization of forest cover loss is therefore necessary to understand its impacts and plan its management. We characterized forest clearing using spatial models in a Geographical Information System, applying morphological image processing to the Forets d’Afrique Central Evaluee par Teledetection product. This process allowed us to create forest fragmentation maps for 2000, 2005 and 2010, classifying previously homogenous primary forest into separate patch, edge, perforated, fragmented and core forest subtypes. Subsequently we used spatial rules to map the established rural complex separately from isolated forest perforations, tracking the growth of these areas in time. Results confirm that the expansion of the rural complex and forest perforations has high variance throughout the country, with consequent differences in local impacts on forest ecology and habitat fragmentation. Between 2000 and 2010 the rural complex grew by 10.2% (46 182 ha), increasing from 11.9% to 13.1% of the total land area (1.2% change) while perforated forest grew by 74.4% (23 856 ha), from 0.8% to 1.5%. Core forest decreased by 3.8% (54 852 ha), from 38% to 36.6% of the 2010 land area. Of particular concern is the nearly doubling of perforated forest, a land dynamic that represents greater spatial intrusion of forest clearing within core forest areas and a move away from the established rural complex.
Dündar, Rıza; Soy, Fatih Kemal; Kulduk, Erkan; Muluk, Nuray Bayar; Cingi, Cemal
2014-10-01
The aim of this study was to introduce a new grafting technique in tympanoplasty that involves use of a boomerang-shaped chondroperichondrial graft (BSCPG). The anatomical and functional results were evaluated. A new tympanoplasty with boomerang-shaped chondroperichondrial graft (TwBSCPG) technique was used in 99 chronic otitis media patients with central or marginal perforation of the tympanic membrane and a normal middle ear mucosa. All 99 patients received chondroperichondrial cartilage grafts with a boomerang-shaped cartilage island left at the anterior and inferior parts. Postoperative follow-ups were conducted at months 1, 6, and 12. Preoperative and postoperative audiological examinations were performed and air-bone gaps were calculated according to the pure-tone averages (PTAs) of the patients. In the preoperative period, most (83.8%) air-bone gaps were ≥ 16 dB; after operating using the TwBSCPG technique, the air-bone gaps decreased to 0-10 dB in most patients (77.8%). In the TwBSCPG patients, the mean preoperative air-bone gap was 22.02 ± 6.74 dB SPL. Postoperatively, the mean postoperative air-bone gap was 8.70 ± 5.74 dB SPL. The TwBSCPG technique therefore decreased the postoperative air-bone gap compared to that preoperatively (p = 0.000, z = -8.645). At the 1-month follow-up, there were six graft perforations and one graft retraction. At the 6-month follow-up, there were nine graft perforations and three graft retractions. At 12 months, there were seven graft perforations and four graft retractions. During the first year after the boomerang tympanoplasty surgery, graft lateralization was not detected in any patient. Retractions were grade 1 according to the Sade classification and were localized to the postero-superior quadrant of the tympanic membrane. The TwBSCPG technique has benefits with respect to postoperative anatomical and audiological results. It prevents perforation of the tympanic membrane at the anterior quadrant and avoids graft lateralization due to placement of the graft under the manubrium mallei. Given these benefits, the TwBSCPG technique seems to be a good alternative for grafting in tympanoplasties.
Joo, Sung-Pil; Kim, Tae-Sun
2017-01-01
Clipping for intracranial aneurysms is done to achieve complete occlusion of the aneurysm without a remnant sac. Despite modern advancements of neurosurgical techniques, morbidity related to the clipping of intracranial aneurysms still exists. Clip occlusion of a parent artery or small hidden perforators commonly leads to permanent neurological deficits, and is a serious and unwanted complication. Thus, preserving blood flow in the branches and perforators of a parent artery is very important for successful surgery without postoperative morbidity and mortality. The aim of this review article is to discuss the consequences of perforator injury and how to avoid this phenomenon in aneurysm surgeries using intraoperative monitoring devices.
Rozen, Warren M; Fox, Carly M; Leong, James; Morsi, Adel
2013-11-01
Multiple variations of the musculocutaneous trapezius flap have been described, each of which use a single composite musculocutaneous unit in their designs. The limitation of such designs is the ability to use the components in a 3-dimensional manner, with only 1 vector existing in the geometry of the musculocutaneous unit. A review of the literature was undertaken with regard to designs of the musculocutaneous trapezius flap, and we present a new technique for flap design. With identification of individual perforators to each of the muscle and fasciocutaneous portions of the trapezius flap, the 2 components can act in a chimeric fashion, able to fill both a deep and complex 3-dimensional space while covering the wound with robust skin. A range of flap designs have been described, including transverse, oblique, and vertical skin paddles accompanying the trapezius muscle. We describe a technique with which a propeller-style skin paddle based on a cutaneous perforator can be raised in any orientation with respect to the underlying muscle. In a presented case, separation of the muscular and fasciocutaneous components of the trapezius flap was able to obliterate dead space around exposed cervicothoracic spinal metalwork and obtain robust wound closure in a patient with previous radiotherapy. This concomitant use of a muscle and fasciocutaneous perforator flap based on a single perforator, a so-called chimeric perforator flap, is a useful modification to trapezius musculocutaneous flap design.
Yoshida, Naohisa; Yagi, Nobuaki; Naito, Yuji; Yoshikawa, Toshikazu
2010-01-01
Endoscopic submucosal dissection (ESD) is efficient for en bloc resection of large colorectal tumors. However, it has several technical difficulties, because the wall of the colon is thin and due to the winding nature of the colon. The main complications of ESD comprise postoperative perforation and hemorrhage, similar to endoscopic mucosal resection (EMR). In particular, the rate of perforation in ESD is higher than that in EMR. Perforation of the colon can cause fatal peritonitis. Endoscopic clipping is reported to be an efficient therapy for perforation. Most cases with perforation are treated conservatively without urgent surgical intervention. However, the rate of postoperative hemorrhage in ESD is similar to that in EMR. Endoscopic therapy including endoscopic clipping is performed and most of the cases are treated conservatively without blood transfusion. In blood examination, some degree of inflammation is detected after ESD. For the standardization of ESD, it is most important to decrease the rate of perforation. Adopting a safe strategy for ESD and a suitable choice of knife are both important ways of preventing perforation. Moreover, appropriate training and increasing experience can improve the endoscopic technique and can decrease the rate of perforation. In this review, we describe safe procedures in ESD to prevent complications, the complications of ESD and their management. PMID:20379999
MRA of the skin: mapping for advanced breast reconstructive surgery.
Thimmappa, N D; Vasile, J V; Ahn, C Y; Levine, J L; Prince, M R
2018-02-27
Autologous breast reconstruction using muscle-sparing free flaps are becoming increasingly popular, although microvascular free flap reconstruction has been utilised for autologous breast reconstructions for >20 years. This innovative microsurgical technique involves meticulous dissection of artery-vein bundle (perforators) responsible for perfusion of the subcutaneous fat and skin of the flap; however, due to unpredictable anatomical variations, preoperative imaging of the donor site to select appropriate perforators has become routine. Preoperative imaging also reduces operating time and enhances the surgeon's confidence in choosing the appropriate donor site for harvesting flaps. Although computed tomography angiography has been widely used for preoperative imaging, concerns over excessive exposure to ionising radiation and poor iodinated contrast agent enhancement of the intramuscular perforator course has made magnetic resonance angiography, the first choice imaging modality in our centre. Magnetic resonance angiography with specific post-processing of the images has established itself as a reliable method for mapping tiny perforator vessels. Multiple donor sites can be imaged in a single setting without concern for ionising radiation exposure. This provides anatomical information of more reconstruction donor site options, so that a surgeon can design a flap of tissue centralised around the best perforator, as well as a back-up perforator, and even a back-up flap option located on a different region of the body. This information is especially helpful in patients with a history of scar tissue from previous surgeries, where the primary choice perforator is found to be damaged or unsuitable intraoperatively. In addition, chest magnetic resonance angiography evaluates recipient site blood vessel suitability including vessel diameters, course, and branching patterns. In this article we provide a broad overview of various skin flaps, clinical indications, advantages and disadvantages of each of these flaps, basic imaging technique, along with advanced sequences for visualising tiny arteries in the groin and in the chest. Post-processing techniques, structure of the report and how automation of the reporting system improves workflow is described. We also describe applications of magnetic resonance angiography in postoperative imaging. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Hydraulic fracturing system and method
Ciezobka, Jordan; Salehi, Iraj
2017-02-28
A hydraulic fracturing system and method for enhancing effective permeability of earth formations to increase hydrocarbon production, enhance operation efficiency by reducing fluid entry friction due to tortuosity and perforation, and to open perforations that are either unopened or not effective using traditional techniques, by varying a pump rate and/or a flow rate to a wellbore.
Hydraulic fracturing system and method
Ciezobka, Jordan; Maity, Debotyam
2018-01-30
A hydraulic fracturing system and method for enhancing effective permeability of earth formations to increase hydrocarbon production, enhance operation efficiency by reducing fluid entry friction due to tortuosity and perforation, and to open perforations that are either unopened or not effective using traditional techniques, by varying a pump rate and/or a flow rate to a wellbore.
Hydraulic fracturing system and method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ciezobka, Jordan; Maity, Debotyam
A hydraulic fracturing system and method for enhancing effective permeability of earth formations to increase hydrocarbon production, enhance operation efficiency by reducing fluid entry friction due to tortuosity and perforation, and to open perforations that are either unopened or not effective using traditional techniques, by varying a pump rate and/or a flow rate to a wellbore.
Niumsawatt, Vachara; Debrotwir, Andrew N; Rozen, Warren Matthew
2014-01-01
Computed tomographic angiography (CTA) has become a mainstay in preoperative perforator flap planning in the modern era of reconstructive surgery. However, the increased use of CTA does raise the concern of radiation exposure to patients. Several techniques have been developed to decrease radiation dosage without compromising image quality, with varying results. The most recent advance is in the improvement of image reconstruction using an adaptive statistical iterative reconstruction (ASIR) algorithm. We sought to evaluate the image quality of ASIR in preoperative deep inferior epigastric perforator (DIEP) flap surgery, through a direct comparison with conventional filtered back projection (FBP) images. A prospective review of 60 consecutive ASIR and 60 consecutive FBP CTA images using similar protocol (except for radiation dosage) was undertaken, analyzed by 2 independent reviewers. In both groups, we were able to accurately identify axial arteries and their perforators. Subjective analysis of image quality demonstrated no statistically significant difference between techniques. ASIR can thus be used for preoperative imaging with similar image quality to FBP, but with a 60% reduction in radiation delivery to patients.
Shin, Hong-In; Sohn, Dong-Seok
2005-12-01
To augment the atrophic posterior maxilla, a sinus bone graft has been widely used for sinus floor augmentation. Various bone substitutes have been developed and grafted in the maxillary sinus with and without membranes perforation, although autogenous bone is recommended as a gold standard of grafting materials. Membrane perforation is the most common complication associated with sinus bone graft. To repair a perforation, various methods have been developed. This case report is focused on histologic findings of 1 bovine hydroxyapatite (Bio-Oss; Geistlich Pharma AG, Wolhusen, Switzerland) and 2 kinds of human mineral allograft- Tutoplast cancellous microchips (TutoGen Medical GmbH, Neunkirchen am. Brand Germany), and irradiated allogeniccancellous bone and marrow (ICB; Rocky Mountain Tissue Bank, Aurora, CO) used for sinus graft in the same patient with membrane perforation after various healing periods. Mineral allograft showed favorable new bone regeneration with the repair of membrane perforation. This case report also describes a technique regarding how to repair completely perforated sinus membrane after the removal of a mucocele using human collagen membrane (Tutoplast pericardium; TutoGen Medical GmbH) and fibrin adhesive (Greenplast; Green Cross Co., Youngin, Korea) to stabilize collagen membrane.
Cifuentes, Ignacio Javier; Dagnino, Bruno Leonardo; Salisbury, María Carolina; Perez, María Eliana; Ortega, Claudia; Maldonado, Daniela
2018-05-01
Dynamic infrared thermography (DIRT) has been used for the preoperative mapping of cutaneous perforators. This technique has shown a positive correlation with intraoperative findings. Our aim was to evaluate the accuracy of perforator mapping with DIRT and augmented reality using a portable projector. For this purpose, three volunteers had both of their anterolateral thighs assessed for the presence and location of cutaneous perforators using DIRT. The obtained image of these "hotspots" was projected back onto the thigh and the presence of Doppler signals within a 10-cm diameter from the midpoint between the lateral patella and the anterior superior iliac spine was assessed using a handheld Doppler device. Hotspots were identified in all six anterolateral thighs and were successfully projected onto the skin. The median number of perforators identified within the area of interest was 5 (range, 3-8) and the median time needed to identify them was 3.5 minutes (range, 3.3-4.0 minutes). Every hotspot was correlated to a Doppler sound signal. In conclusion, augmented reality can be a reliable method for transferring the location of perforators identified by DIRT onto the thigh, facilitating its assessment and yielding a reliable map of potential perforators for flap raising.
Haine, Aung Thu; Koga, Yuki; Hashimoto, Yuta; Higashi, Taishi; Motoyama, Keiichi; Arima, Hidetoshi; Niidome, Takuro
2017-10-01
Transdermal protein delivery is a useful and attractive method for protein therapy and dermal vaccination. However, this delivery method is restricted by the low permeability of the stratum corneum. The purpose of this study was to develop a transdermal delivery system for enhancement of protein permeability into the skin. First, we prepared a transparent gel patch made of polysaccharides with gold nanorods on the gel surface and fluorescein isothiocyanate-modified ovalbumin (FITC-OVA) inside. Next, the gel patch was placed on mouse skin to allow contact with the coated gold nanorods, and irradiated by a continuous-wave laser. The laser irradiation heated the gold nanorods and the skin temperature increased to 43°C, resulting in enhanced translocation of FITC-OVA into the skin. These results confirmed the capability of the transdermal protein delivery system to perforate the stratum corneum and thus facilitate the passage of proteins across the skin. Copyright © 2017 Elsevier B.V. All rights reserved.
Nasoseptal Perforation: from Etiology to Treatment.
Pereira, Carla; Santamaría, Alfonso; Langdon, Cristobal; López-Chacón, Mauricio; Hernández-Rodríguez, José; Alobid, Isam
2018-02-05
Nasal septum perforation (NSP) is a communication between the two nasal cavities. This review contributes to the better knowledge of NSP causes, diagnosis, and treatment. NSP prevalence is about 1%. Clinical presentation may range from absence of symptoms to the presence of bothersome sinonasal symptoms. NSP is more frequently caused by trauma or post-surgery, inflammatory diseases, and abuse substances. Conservative management (nasal irrigation, topical use of antibiotic or lubricant ointments, or placement of prosthesis) is considered the first-line treatment. Symptomatic NSP not improving with local therapies usually requires surgical approach. Selection of the technique for the endoscopic septal repair depends on perforation characteristics and surgeon experience. When NSP is diagnosed, its cause has to be promptly determined. Most of them can be controlled with conservative measures. Surgical/endoscopic approaches are usually needed in refractory cases, and new repair techniques have to be considered.
Upadhye, Kalpesh V.; Candiello, Joseph E.; Davidson, Lance A.; Lin, Hai
2011-01-01
Patch clamp is a powerful tool for studying the properties of ion-channels and cellular membrane. In recent years, planar patch clamp chips have been fabricated from various materials including glass, quartz, silicon, silicon nitride, polydimethyl-siloxane (PDMS), and silicon dioxide. Planar patch clamps have made automation of patch clamp recordings possible. However, most planar patch clamp chips have limitations when used in combination with other techniques. Furthermore, the fabrication methods used are often expensive and require specialized equipments. An improved design as well as fabrication and characterization of a silicon-based planar patch clamp chip are described in this report. Fabrication involves true batch fabrication processes that can be performed in most common microfabrication facilities using well established MEMS techniques. Our planar patch clamp chips can form giga-ohm seals with the cell plasma membrane with success rate comparable to existing patch clamp techniques. The chip permits whole-cell voltage clamp recordings on variety of cell types including Chinese Hamster Ovary (CHO) cells and pheochromocytoma (PC12) cells, for times longer than most available patch clamp chips. When combined with a custom microfluidics chamber, we demonstrate that it is possible to perfuse the extra-cellular as well as intra-cellular buffers. The chamber design allows integration of planar patch clamp with atomic force microscope (AFM). Using our planar patch clamp chip and microfluidics chamber, we have recorded whole-cell mechanosensitive (MS) currents produced by directly stimulating human keratinocyte (HaCaT) cells using an AFM cantilever. Our results reveal the spatial distribution of MS ion channels and temporal details of the responses from MS channels. The results show that planar patch clamp chips have great potential for multi-parametric high throughput studies of ion channel proteins. PMID:22174731
Parasacral Perforator Flaps for Reconstruction of Sacral Pressure Sores.
Lin, Chin-Ta; Chen, Shih-Yi; Chen, Shyi-Gen; Tzeng, Yuan-Sheng; Chang, Shun-Cheng
2015-07-01
Despite advances in reconstruction techniques, pressure sores continue to present a challenge to the plastic surgeon. The parasacral perforator flap is a reliable flap that preserves the entire contralateral side as a future donor site. On the ipsilateral side, the gluteal muscle itself is preserved and all flaps based on the inferior gluteal artery are still possible. We present our experience of using parasacral perforator flaps in reconstructing sacral defects. Between August 2004 and January 2013, 19 patients with sacral defects were included in this study. All the patients had undergone surgical reconstruction of sacral defects with a parasacral perforator flap. The patients' sex, age, cause of sacral defect, flap size, flap type, numbers of perforators used, rotation angle, postoperative complications, and hospital stay were recorded. There were 19 parasacral perforator flaps in this series. All flaps survived uneventfully except for 1 parasacral perforator flap, which failed because of methicillin-resistant Staphylococcus aureus infection. The overall flap survival rate was 95% (18/19). The mean follow-up period was 17.3 months (range, 2-24 months). The average length of hospital stay was 20.7 days (range, 9-48 days). No flap surgery-related mortality was found. Also, there was no recurrence of sacral pressure sores or infected pilonidal cysts during the follow-up period. Perforator-based flaps have become popular in modern reconstructive surgery because of low donor-site morbidity and good preservation of muscle. Parasacral perforator flaps are durable and reliable in reconstructing sacral defects. We recommend the parasacral perforator flap as a good choice for reconstructing sacral defects.
Incidence and patterns of surgical glove perforations: experience from Addis Ababa, Ethiopia.
Bekele, Abebe; Makonnen, Nardos; Tesfaye, Lidya; Taye, Mulat
2017-03-20
Surgical glove perforation is a common event. The operating staff is not aware of the perforation until the procedure is complete, sometimes in as high as 70% of the incidences. Data from Ethiopia indicates that the surgical workforce suffers from a very surgery related accidents, however there is paucity of data regarding surgical glove perforation. The main objective is to describe the incidence and patterns of surgical glove perforation during surgical procedures and to compare the rates between emergency and elective surgeries at one of the main hospitals in Addis Ababa Ethiopia. This is a prospective study, performed at the Minilik II referral hospital, Addis Ababa. All surgical gloves worn during all major surgical procedures (Emergency and Elective) from June 1-July 20, 2016 were collected and used for the study. Standardised visual and hydro insufflation techniques were used to test the gloves for perforations. Parameters recorded included type of procedure performed, number of perforations, localisation of perforation and the roles of the surgical team. A total of 2634 gloves were tested, 1588 from elective and 1026 from emergency procedures. The total rate of perforation in emergency procedures was 41.4%, while perforation in elective surgeries was 30.0%. A statistically significant difference (P < 0.05) was found in between emergency and elective surgeries. There were a very high rate of perforations of gloves among first surgeons 40.6% and scrub nurses 38.8% during elective procedures and among first surgeons (60.14%), and second assistants (53.0%) during emergency surgeries. Only 0.4% of inner gloves were perforated. The left hand, the left index finger and thumb were the most commonly perforated parts of the glove. Glove perforation rate was low among consultant surgeons than residents. Our reported perforation rate is higher than most publications, and this shows that the surgical workforce in Ethiopia is under a clear and present threat. Measures such as double gloving seems to have effectively prevented cutaneous blood exposure and thus should become a routine for all surgical procedures. Manufacturing related defects and faults in glove quality may also be contributing factors.
Endoscopic duodenal perforation: surgical strategies in a regional centre
2014-01-01
Background Duodenal perforation is an uncommon complication of endoscopic retrograde cholangio-pancreatography (ERCP) and a rare complication of upper gastrointestinal endoscopy. Most are minor perforations that settle with conservative management. A few perforations however result in life-threatening retroperitoneal necrosis and require surgical intervention. There is a relative paucity of references specifically describing the surgical interventions required for this eventuality. Methods Five cases of iatrogenic duodenal perforation were ascertained between 2002 and 2007 at Cairns Base Hospital. Clinical features were analyzed and compared, with reference to a review of ERCP at that institution for the years 2005/2006. Results One patient recovered with conservative management. Of the other four, one died after initial laparotomy. The other three survived, undergoing multiple procedures and long inpatient stays. Conclusions Iatrogenic duodenal perforation with retroperitoneal necrosis is an uncommon complication of endoscopy, but when it does occur it is potentially life-threatening. Early recognition may lead to a better outcome through earlier intervention, although a protracted course with multiple procedures should be anticipated. A number of surgical techniques may need to be employed according to the individual circumstances of the case. PMID:24461069
Jarriault, David; Grosmaitre, Xavier
2015-01-01
Analyzing the physiological responses of olfactory sensory neurons (OSN) when stimulated with specific ligands is critical to understand the basis of olfactory-driven behaviors and their modulation. These coding properties depend heavily on the initial interaction between odor molecules and the olfactory receptor (OR) expressed in the OSNs. The identity, specificity and ligand spectrum of the expressed OR are critical. The probability to find the ligand of the OR expressed in an OSN chosen randomly within the epithelium is very low. To address this challenge, this protocol uses genetically tagged mice expressing the fluorescent protein GFP under the control of the promoter of defined ORs. OSNs are located in a tight and organized epithelium lining the nasal cavity, with neighboring cells influencing their maturation and function. Here we describe a method to isolate an intact olfactory epithelium and record through patch-clamp recordings the properties of OSNs expressing defined odorant receptors. The protocol allows one to characterize OSN membrane properties while keeping the influence of the neighboring tissue. Analysis of patch-clamp results yields a precise quantification of ligand/OR interactions, transduction pathways and pharmacology, OSNs' coding properties and their modulation at the membrane level. PMID:26275097
Dadak, Selma; Beall, Craig; Vlachaki Walker, Julia M; Soutar, Marc P M; McCrimmon, Rory J; Ashford, Michael L J
2017-03-27
The unsaturated fatty acid, oleate exhibits anorexigenic properties reducing food intake and hepatic glucose output. However, its mechanism of action in the hypothalamus has not been fully determined. This study investigated the effects of oleate and glucose on GT1-7 mouse hypothalamic cells (a model of glucose-excited (GE) neurons) and mouse arcuate nucleus (ARC) neurons. Whole-cell and perforated patch-clamp recordings, immunoblotting and cell energy status measures were used to investigate oleate- and glucose-sensing properties of mouse hypothalamic neurons. Oleate or lowered glucose concentration caused hyperpolarization and inhibition of firing of GT1-7 cells by the activation of ATP-sensitive K + channels (K ATP ). This effect of oleate was not dependent on fatty acid oxidation or raised AMP-activated protein kinase activity or prevented by the presence of the UCP2 inhibitor genipin. Oleate did not alter intracellular calcium, indicating that CD36/fatty acid translocase may not play a role. However, oleate activation of K ATP may require ATP metabolism. The short-chain fatty acid octanoate was unable to replicate the actions of oleate on GT1-7 cells. Although oleate decreased GT1-7 cell mitochondrial membrane potential there was no change in total cellular ATP or ATP/ADP ratios. Perforated patch and whole-cell recordings from mouse hypothalamic slices demonstrated that oleate hyperpolarized a subpopulation of ARC GE neurons by K ATP activation. Additionally, in a separate small population of ARC neurons, oleate application or lowered glucose concentration caused membrane depolarization. In conclusion, oleate induces K ATP- dependent hyperpolarization and inhibition of firing of a subgroup of GE hypothalamic neurons without altering cellular energy charge. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Shelat, Vishal G.; Ahmed, Saleem; Chia, Clement L. K.; Cheah, Yee Lee
2015-01-01
Application of minimal access surgery in acute care surgery is limited due to various reasons. Laparoscopic omental patch repair (LOPR) for perforated peptic ulcer (PPU) surgery is safe and feasible but not widely implemented. We report our early experience of LOPR with emphasis on strict selection criteria. This is a descriptive study of all patients operated on for PPU at academic university-affiliated institutes from December 2010 to February 2012. All the patients who were operated on for LOPR were included as the study population and their records were studied. Perioperative outcomes, Boey score, Mannheim Peritonitis Index (MPI), and physiologic and operative severity scores for enumeration of mortality and morbidity (POSSUM) scores were calculated. All the data were tabulated in a Microsoft Excel spreadsheet and analyzed using Stata Version 8.x. (StataCorp, College Station, TX, USA). Fourteen patients had LOPR out of a total of 45 patients operated for the PPU. Mean age was 46 years (range 22−87 years). Twelve patients (86%) had a Boey score of 0 and all patients had MPI < 21 (mean MPI = 14). The predicted POSSUM morbidity and mortality were 36% and 7%, respectively. Mean ulcer size was 5 mm (range 2−10 mm), mean operating time was 100 minutes (range 70−123 minutes) and mean length of hospital stay was 4 days (range 3−6 days). There was no morbidity or mortality pertaining to LOPR. LOPR should be offered by acute care surgical teams when local expertise is available. This can optimize patient outcomes when strict selection criteria are applied. PMID:25692444
A fibrin sealant for perforated and preperforated corneal ulcers.
Lagoutte, F M; Gauthier, L; Comte, P R
1989-01-01
Fibrin sealant is used to close perforated or preperforated corneal ulcers. In addition to the usual advantages of cyanoacrylates it is degraded physiologically and provides a good support for corneal healing. Corneal grafting can be avoided when contraindicated or postponed when conditions allow. This technique has been successful in nine eyes of eight patients. Images PMID:2804032
Experience with acute perforated duodenal ulcer in a West African population.
Nuhu, A; Kassama, Y
2008-01-01
The advent of proton pump inhibitors and helicobacter pylori eradication in the management of chronic peptic ulcer disease has reduced the operative treatment of this condition to its complications. Perforated duodenal ulcer remains a major life threatening complication of chronic peptic ulcer disease. This retrospective study reviews our experience at the Royal Victoria Teaching Hospital. All patients with clinical diagnosis of perforated duodenal ulcer seen in this hospital between June 2003 and October 2005 were included in this study. Data extracted from their hospital records were analyzed for age, sex, duration of symptoms, previous history of peptic ulcer disease, use of NSAIDS, main presenting features, investigations, resuscitative measures, time of surgery, operative findings, and type of surgery offered, complications and mortality. After resuscitation, laparotomy followed by simple closure or definitive ulcer surgery and helicobacter pylori eradication therapy was given to all the patients. Duration of follow up ranged 8 to 12 months with endoscopy in some patients. There were 41 patients with intraoperative diagnosis of acute perforated duodenal ulcer seen over the study period, comprising 34 males (82.9%) and 7 females (17.1%), a male female ratio of 4.8:1, age range of 18-77 years and a mean age of 45.49 +/- 14.46 years. Previous history of peptic ulcer disease was found in 32 (78.6%) of the patient and the main presenting features were sudden onset of severe abdominal pain in 95.1% of cases and fever in 65.8%. Features of frank peritonitis were demonstrable in all the patients and 11 (26.8%) presented in shock. Plain chest x-rays demonstrated gas under the diaphragm in 21(65.6%) of the patients. After adequate resuscitation, all the patients underwent laparotomy where the abdomen was explored, the diagnosis of perforated duodenal ulcer was confirmed and 29 (70.7%) had simple closure of the perforation with omentum (after Graham). The average time between presentation and surgery was 9 hours (range 6-11 hours). The mean size of perforation was 10.5 mm (range 5-15 mm). Definitive peptic ulcer surgery was done in 12 (29.3%) patients. 8 had truncal vagotomy and pyloroplasty. The major complications included wound infection in 14 (34.1%), postoperative fever in 16 (39.0%) and prolonged ileus in 15 (36.6%) There were 7 deaths, mortality rate of 17.1% and the causes of death included severe electrolyte imbalance in 1 and gram negative septicaemia and shock in 6. The average duration of hospital stay was 10 days (range 8-36). Perforated duodenal ulcer is a major complication of chronic peptic ulcer disease. Simple omental patch by open method and helicobacter pylori eradication therapy is sufficient to prevent reperforation.
Ren, Xinyu; Lv, Yingying; Li, Mingshi
2017-03-01
Changes in forest ecosystem structure and functions are considered some of the research issues in landscape ecology. In this study, advancing Forman's theory, we considered five spatially explicit processes associated with fragmentation, including perforation, dissection, subdivision, shrinkage, and attrition, and two processes associated with restoration, i.e., increment and expansion processes. Following this theory, a forest fragmentation and restoration process model that can detect the spatially explicit processes and ecological consequences of forest landscape change was developed and tested in the current analysis. Using the National Land Cover Databases (2001, 2006 and 2011), the forest fragmentation and restoration process model was applied to US western natural forests and southeastern plantation forests to quantify and classify forest patch losses into one of the four fragmentation processes (the dissection process was merged into the subdivision process) and to classify the newly gained forest patches based on the two restoration processes. At the same time, the spatio-temporal differences in fragmentation and restoration patterns and trends between natural forests and plantations were further compared. Then, through overlaying the forest fragmentation/restoration processes maps with targeting year land cover data and land ownership vectors, the results from forest fragmentation and the contributors to forest restoration in federal and nonfederal lands were identified. Results showed that, in natural forests, the forest change patches concentrated around the urban/forest, cultivated/forest, and shrubland/forest interfaces, while the patterns of plantation change patches were scattered sparsely and irregularly. The shrinkage process was the most common type in forest fragmentation, and the average size was the smallest. Expansion, the most common restoration process, was observed in both natural forests and plantations and often occurred around the previous expansion or covered the previous subdivision or shrinkage processes. The overall temporal fragmentation pattern of natural forests had a "perforation-subdivision/shrinkage-attrition" pathway, which corresponded to Forman's landscape fragmentation rule, while the plantation forests did not follow the rule strictly. The main land cover types resulted from forest fragmentation in natural forests and plantation forests were shrubland and herbaceous, mainly through subdivision and shrinkages process. The processes and effects of restoration of plantation forests were more diverse and efficient, compared to the natural forest, which were simpler with a lower regrowth rate. The fragmentation mostly occurred in nonfederal lands. In natural forests, forest fragmentation pattern differed in different land tenures, yet plantations remained the same in federal and nonfederal lands. Copyright © 2016 Elsevier Ltd. All rights reserved.
Risk of surgical glove perforation in oral and maxillofacial surgery.
Kuroyanagi, N; Nagao, T; Sakuma, H; Miyachi, H; Ochiai, S; Kimura, Y; Fukano, H; Shimozato, K
2012-08-01
Oral and maxillofacial surgery, which involves several sharp instruments and fixation materials, is consistently at a high risk for cross-contamination due to perforated gloves, but it is unclear how often such perforations occur. This study aimed to address this issue. The frequency of the perforation of surgical gloves (n=1436) in 150 oral and maxillofacial surgeries including orthognathic surgery (n=45) was assessed by the hydroinsufflation technique. Orthognathic surgery had the highest perforation rate in at least 1 glove in 1 operation (91.1%), followed by cleft lip and palate surgery (55.0%), excision of oral soft tumour (54.5%) and dental implantation (50.0%). The perforation rate in scrub nurses was 63.4%, followed by 44.4% in surgeons and first assistants, and 16.3% in second assistants. The odds ratio for the perforation rate in orthognathic surgery versus other surgeries was 16.0 (95% confidence interval: 5.3-48.0). The protection rate offered by double gloving in orthognathic surgery was 95.2%. These results suggest that, regardless of the surgical duration and blood loss in all fields of surgery, orthognathic surgery must be categorized in the highest risk group for glove perforation, following gynaecological and open lung surgery, due to the involvement of sharp objects. Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Matteini, Paolo; Banchelli, Martina; Cottat, Maximilien; Osticioli, Iacopo; de Angelis, Marella; Rossi, Francesca; Pini, Roberto
2016-03-01
In previous works a minimally invasive laser-assisted technique for vascular repair was presented. The technique rests on the photothermal adhesion of a biocompatible and bioresorbable patch containing Indocyanine Green that is brought into contact with the site to be repaired. Afterward the use of NIR millisecond-long light pulses generates a strong welding effect between the patch and the underlying tissue and in turn the repair of the wound. This technique was shown to be effective in animal model and provides several advantages over conventional suturing methods. Here we investigate and discuss the optical stability of the ICG-biopolymeric patches and the photothermal effects induced to the irradiated tissue.
Prediction of Fatigue Crack Growth of Repaired Al-alloy Structures with Double Sides
NASA Astrophysics Data System (ADS)
Benachour, M.; Benachour, N.; Benguediab, M.; Seriari, F. Z.
During navigation, aircrafts are subject to fatigue damage. In order to rehabilitate damaged structures some techniques are often used to resolve this problem. Efficient repair technique, called composite patch repair, was used to reinforce the damaged structures and stop cracks. In this paper, effect of composite patch repair (Boron/Epoxy) on fatigue crack growth (FCG) was investigated on 2219 T62 Al-alloy. Effects of double patch repair in single notch tensile specimen (SENT) on FCG were studied and compared to single patch repair. Results show beneficial effect of patch repair on fatigue life and FCGR in comparison with the un-patched specimen. In addition, effect of mean stress characterized by stress ratio was highlighted. Fatigue behavior of investigated Al-alloy was compared.
Sarkar, Gunjan; Saha, Nayan Ranjan; Roy, Indranil; Bhattacharyya, Amartya; Bose, Madhura; Mishra, Roshnara; Rana, Dipak; Bhattacharjee, Debashis; Chattopadhyay, Dipankar
2014-05-01
The aim of this work is to examine the effectiveness of mucilage/hydroxypropylmethylcellulose (HPMC) based transdermal patch (matrix type) as a drug delivery device. We have successfully extracted mucilage from Colocasia esculenta (Taro) corms and prepared diltiazem hydrochloride incorporated mucilage/HPMC based transdermal patches using various wt% of mucilage by the solvent evaporation technique. Characterization of both mucilage and transdermal patches has been done by several techniques such as Molisch's test, organoleptic evaluation of mucilage, mechanical, morphological and thermal analysis of transdermal patches. Skin irritation test is studied on hairless Albino rat skin showing that transdermal patches are apparently free of potentially hazardous skin irritation. Fourier transform infrared analysis shows that there is no interaction between drug, mucilage and HPMC while scanning electron microscopy shows the surface morphology of transdermal patches. In vitro drug release time of mucilage-HPMC based transdermal patches is prolonged with increasing mucilage concentration in the formulation. Copyright © 2014 Elsevier B.V. All rights reserved.
Minimally invasive transcanal myringotomy for pediatric early stage congenital cholesteatoma.
Jang, Chul Ho; Jung, Eun Kyung; Sung, Chung Man; Kim, Seung Beom; Kim, Young Yoon; Seong, Jong Yuap; Kang, Sung Hoon; Cho, Yong Beom
2016-11-01
Recently, minimally invasive transcanal myringotomy (MITM), which is a useful surgical technique for early stage congenital cholesteatoma (CC) in children, was introduced. The purpose of this study is to evaluate the short-term surgical results of MITM in pediatric early stage CC. We retrospectively reviewed the charts of 24 patients who underwent MITM between January 2013 and October 2015. The patients' ages ranged from 1 to 16 years (mean, 2.6 years). There were 17 male and 7 female patients. The right side (n = 13) was affected twice as often as the left side (n = 11). The most common site was the anterosuperior quadrant (15 cases). The diameter of the CC on axial computed tomography images ranged from 2.8 to 5.7 mm (mean, 3.9 mm). CCs were graded according to Potsic's system: 18 cases were classified as stage I, 3 case as stage II, and 3 cases as stage III. AllCCs except 1 were closed type. In21 patients, the tympanic membrane closed naturally without recurrence. Three patients showed small persistent dry perforation. Natural closure occurred in these patients, who were treated with paper patches. MITM is a simple, effective technique for removing an early stage CC from the middle ear, and it can minimize operative time, length of hospitalization, and postoperative morbidity. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Cifuentes, Ignacio Javier; Dagnino, Bruno Leonardo; Salisbury, María Carolina; Perez, María Eliana; Ortega, Claudia; Maldonado, Daniela
2018-01-01
Dynamic infrared thermography (DIRT) has been used for the preoperative mapping of cutaneous perforators. This technique has shown a positive correlation with intraoperative findings. Our aim was to evaluate the accuracy of perforator mapping with DIRT and augmented reality using a portable projector. For this purpose, three volunteers had both of their anterolateral thighs assessed for the presence and location of cutaneous perforators using DIRT. The obtained image of these “hotspots” was projected back onto the thigh and the presence of Doppler signals within a 10-cm diameter from the midpoint between the lateral patella and the anterior superior iliac spine was assessed using a handheld Doppler device. Hotspots were identified in all six anterolateral thighs and were successfully projected onto the skin. The median number of perforators identified within the area of interest was 5 (range, 3–8) and the median time needed to identify them was 3.5 minutes (range, 3.3–4.0 minutes). Every hotspot was correlated to a Doppler sound signal. In conclusion, augmented reality can be a reliable method for transferring the location of perforators identified by DIRT onto the thigh, facilitating its assessment and yielding a reliable map of potential perforators for flap raising. PMID:29788686
Behavior of poly(glycerol sebacate) plugs in chronic tympanic membrane perforations.
Sundback, C A; McFadden, J; Hart, A; Kulig, K M; Wieland, A M; Pereira, M J N; Pomerantseva, I; Hartnick, C J; Masiakos, P T
2012-10-01
The tympanic membrane (TM), separating the external and middle ear, consists of fibrous connective tissue sandwiched between epithelial layers. To treat chronic ear infections, tympanostomy drainage tubes are placed in surgically created holes in TMs which can become chronic perforations upon extrusion. Perforations are repaired using a variety of techniques, but are limited by morbidity, unsatisfactory closure rates, or minimal regeneration of the connective tissue. A more effective, minimally-invasive therapy is necessary to enhance the perforation closure rate. Current research utilizing decellularized or alignate materials moderately enhance closure but the native TM architecture is not restored. Poly(glycerol sebacate) (PGS) is a biocompatible elastomer which supports cell migration and enzymatically degrades in contact with vascularized tissue. PGS spool-shaped plugs were manufactured using a novel process. Using minimally invasive procedures, these elastomeric plugs were inserted into chronic chinchilla TM perforations. As previously reported, effective perforation closure occurred as both flange surfaces were covered by confluent cell layers; >90% of perforations were closed at 6-week postimplantation. This unique in vivo environment has little vascularized tissue. Consequently, PGS degradation was minimal over 16-week implantation, hindering regeneration of the TM fibrous connective tissue. PGS degradation must be enhanced to promote complete TM regeneration. Copyright © 2012 Wiley Periodicals, Inc.
Teoh, Raymond; Johnson, Raleigh F; Nishino, Thomas K; Ethridge, Richard T
2007-01-01
The deep inferior epigastric perforator flap procedure has become a popular alternative for women who require breast reconstruction. One of the difficulties with this procedure is identifying perforator arteries large enough to ensure that the harvested tissue is well vascularized. Current techniques involve imaging the perforator arteries with computed tomography (CT) to produce a grid mapping the locations of the perforator arteries relative to the umbilicus. To compare the time it takes to produce a map of the perforators using either two-dimensional (2D) or three-dimensional (3D) CT, and to see whether there is a benefit in using a 3D model. Patient CT abdomen and pelvis scans were acquired from a GE 64-slice scanner. CT image processing was performed with the GE 3D Advantage Workstation v4.2 software. Maps of the perforators were generated both as 2D and 3D representations. Perforators within a region 5 cm rostral and 7 cm caudal to the umbilicus were measured and the times to perform these measurements using both 2D and 3D images were recorded by a stopwatch. Although the 3D method took longer than the 2D method (mean [+/- SD] time 1:51+/-0:35 min versus 1:08+/-0:16 min per perforator artery, respectively), producing a 3D image provides much more information than the 2D images alone. Additionally, an actual-sized 3D image can be printed out, removing the need to make measurements and producing a grid. Although it took less time to create a grid of the perforators using 2D axial CT scans, the 3D reconstruction of the abdomen allows the plastic surgeons to better visualize the patient's anatomy and has definite clinical utility.
Bebbington, M W; Treissman, M J
1996-10-01
Our purpose was to compare the effectiveness of a surgical assist device, SutureMate, to decrease glove perforations during postdelivery vaginal repair. This was a prospective randomized trial. After delivery surgeons who needed to perform vaginal repair were randomized to use the surgical assist device or to perform the repair in the usual fashion. After the repair, gloves were collected and the operator was asked to complete a standardized data form that was submitted with the gloves. The gloves were tested for perforations within 24 hours by the Food and Drug Administration-approved hydrosufflation technique. Comparisons were made with chi(2) statistics with p < 0.01 taken as being statistically significant with the use of a Bonferoni adjustment for multiple comparisons. A total of 476 glove sets were evaluated. The use of the surgical assist device significantly reduced the overall glove perforation rate from 28.3% in the control arm to 8.4% in the study arm (p = 0.0001). Rates of perforation varied with level of training and expertise but fell in all groups that used the device. Family physicians had the highest perforation rate in the control arm and benefited most from the device. A total of 76% of perforations were located in the thumb, index, and second fingers of the nondominant hand. Perforations were recognized in only 16% of the glove sets. The level of satisfaction with the device was mixed, but overall 50% of operators indicated that they were either satisfied or very satisfied with the device. The rate of glove perforation in postdelivery vaginal repair is high. The surgical assist device significantly reduced the rate of glove perforations.
Perforator-Guided Drug Injection in the Treatment of Abdominal Wall Pain.
Weum, Sven; de Weerd, Louis
2016-07-01
Pain from the abdominal wall can be caused by nerve entrapment, a condition called abdominal cutaneous nerve entrapment syndrome (ACNES). As an alternative to surgery, ACNES may be treated with injection of local anesthetics, corticosteroids, or botulinum toxin at the point of maximal pain. The point of maximal pain was marked on the abdominal skin. Using color Doppler ultrasound, the corresponding exit point of perforating blood vessels through the anterior fascia of the rectus abdominis muscle was identified. Ultrasound-guided injection of botulinum toxin in close proximity to the perforator's exit point was performed below and above the muscle fascia. The technique was used from 2008 to 2014 on 15 patients in 46 sessions with a total of 128 injections without complications. The injection technique provided safe and accurate administration of the drug in proximity to the affected cutaneous nerves. The effect of botulinum toxin on ACNES is beyond the scope of this article. Perforator-guided injection enables precise drug administration at the location of nerve entrapment in ACNES in contrast to blind injections. © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Transcanal microscope-assisted endoscopic myringoplasty in children.
Migirov, Lela; Wolf, Michael
2015-04-01
Myringoplasty can be technically difficult in the pediatric patients due to the narrowness of the external auditory canal and the generally small size of the ear. Moreover, temporalis fascia grafts and myringoplasties for anterior perforations are more likely to fail in children. Surgical management of anterior perforations requires total exposure of the anterior angle however a microscope may fail to provide a view of the anterior edge in most of perforations. Recently, different endoscopes are used in the performance of ear surgery in general and myringoplasty in particular. Current study aimed to investigate the outcome of transcanal microscope-assisted endoscopic myringoplasty in homogenous group of children. The medical records of 22 children were retrospectively reviewed for age, perforation size and location, surgical and audiological findings, and outcome. All myringoplasties were performed by first author with a chondro-perichondrial graft that has been harvested from the tragus and placed medial to the tympanic membrane remnants, utilizing the underlay technique and 14-mm length, 3-mm diameter, 0° and 30° endoscopes. A microscope was occasionally used for removal of the sclerotic plaques and releasing adhesions surrounding the ossicles when bimanual manipulations were needed. Surgical success was defined as a tympanic membrane with no perforation, retraction, or graft lateralization for at least 18 months following surgery. Thirteen large-, 8 medium- and 1 small-sized perforations (defined as 75, 50 or 25%, respectively, of the tympanic membrane area), of which 14 were anterior, 2 central and 6 posterior marginal, were repaired. The edges of the defect could not be visualized under a microscope due to bone overhanging or a curved or narrow EAC in 8 anterior perforations. Intact tympanic membranes and dry ears were achieved in all operated children. The audiometric air conduction level (average of 0.5-3 kHz) for the entire cohort ranged between 10-51.3 dB (mean 32.8) preoperatively and between 5-35 dB (mean 18.2) postoperatively. The transcanal microscope-assisted endoscopic myringoplasty had a 100% rate of surgical success in children. This technique can be especially appropriate for patients with narrow external canals, anterior defects and bone overhang making the perforation margins barely visible under a microscope.
Ulm, Christian; Bertl, Kristina; Strbac, Georg D; Esfandeyari, Azadeh; Stavropoulos, Andreas; Zechner, Werner
2017-12-01
Sinus floor augmentation is a routinely used surgical technique for increasing the bone height/volume of the atrophic posterior maxilla. Optimal integration of the implanted augmentation material within the newly formed bone will-at least partly-depend on adequate vascularization to ensure sufficient recruitment of osteoblast and osteoclast precursor cells. The present technical note describes a modification intended to facilitate increased blood inflow into the augmented space. After preparation of the lateral window and elevation of the Schneiderian membrane, the cortical bone of the sinus floor is perforated several times either by using a piezoelectric device or a microsurgical handpiece with the corresponding tip or bur; these perforations should extend into the trabecular bone. The experiences with this modified technique after 12 patients are presented and discussed. It is expected that by means of this relatively simple technique, increased blood and cell inflow into the augmented space is achieved. This may, in turn, enhance new bone formation and improve the integration of the augmentation material.
A New Technique for System-to-system Transfer of Surface Data
NASA Technical Reports Server (NTRS)
Sterling, M. W.; Lucius, M. E.; Gordon, W. J.
1985-01-01
The purpose is to describe a recently developed technique aimed at providing a universal interface between surface types. In brief, a software package was developed which functions a common denominator of CAD/CAM surface types. This software enable one to convert from any given surface representation to any other target representation. The tiles maintain the same slope continuity as the target surface gram, bicubic patches are used since they allow one to match point, slope, and twist vectors to the target surface. Thus, slopes can be continuous or discontinuous as they are on the target surface. The patches can be of lower order if desired. For example, if only point information is available, the patches produced will be bilinear; however, the number of patches required is likely to increase correspondingly. The patches can be of higher order although many systems will not accept patches of more than order four. The final result of the program is a rectangular grid of bicubic patches. The patches fit the target surface exactly at their corners. Also, the patch corners have the same tangent and twist vectors. Adjacent patches will have slope continuity, unless a discontinuity was indicated by the target surface.
An Experimentally Validated Numerical Modeling Technique for Perforated Plate Heat Exchangers
Nellis, G. F.; Kelin, S. A.; Zhu, W.; Gianchandani, Y.
2010-01-01
Cryogenic and high-temperature systems often require compact heat exchangers with a high resistance to axial conduction in order to control the heat transfer induced by axial temperature differences. One attractive design for such applications is a perforated plate heat exchanger that utilizes high conductivity perforated plates to provide the stream-to-stream heat transfer and low conductivity spacers to prevent axial conduction between the perforated plates. This paper presents a numerical model of a perforated plate heat exchanger that accounts for axial conduction, external parasitic heat loads, variable fluid and material properties, and conduction to and from the ends of the heat exchanger. The numerical model is validated by experimentally testing several perforated plate heat exchangers that are fabricated using microelectromechanical systems based manufacturing methods. This type of heat exchanger was investigated for potential use in a cryosurgical probe. One of these heat exchangers included perforated plates with integrated platinum resistance thermometers. These plates provided in situ measurements of the internal temperature distribution in addition to the temperature, pressure, and flow rate measured at the inlet and exit ports of the device. The platinum wires were deposited between the fluid passages on the perforated plate and are used to measure the temperature at the interface between the wall material and the flowing fluid. The experimental testing demonstrates the ability of the numerical model to accurately predict both the overall performance and the internal temperature distribution of perforated plate heat exchangers over a range of geometry and operating conditions. The parameters that were varied include the axial length, temperature range, mass flow rate, and working fluid. PMID:20976021
An Experimentally Validated Numerical Modeling Technique for Perforated Plate Heat Exchangers.
White, M J; Nellis, G F; Kelin, S A; Zhu, W; Gianchandani, Y
2010-11-01
Cryogenic and high-temperature systems often require compact heat exchangers with a high resistance to axial conduction in order to control the heat transfer induced by axial temperature differences. One attractive design for such applications is a perforated plate heat exchanger that utilizes high conductivity perforated plates to provide the stream-to-stream heat transfer and low conductivity spacers to prevent axial conduction between the perforated plates. This paper presents a numerical model of a perforated plate heat exchanger that accounts for axial conduction, external parasitic heat loads, variable fluid and material properties, and conduction to and from the ends of the heat exchanger. The numerical model is validated by experimentally testing several perforated plate heat exchangers that are fabricated using microelectromechanical systems based manufacturing methods. This type of heat exchanger was investigated for potential use in a cryosurgical probe. One of these heat exchangers included perforated plates with integrated platinum resistance thermometers. These plates provided in situ measurements of the internal temperature distribution in addition to the temperature, pressure, and flow rate measured at the inlet and exit ports of the device. The platinum wires were deposited between the fluid passages on the perforated plate and are used to measure the temperature at the interface between the wall material and the flowing fluid. The experimental testing demonstrates the ability of the numerical model to accurately predict both the overall performance and the internal temperature distribution of perforated plate heat exchangers over a range of geometry and operating conditions. The parameters that were varied include the axial length, temperature range, mass flow rate, and working fluid.
von Renteln, Daniel; Rudolph, Hans-Ulrich; Schmidt, Arthur; Vassiliou, Melina C; Caca, Karel
2010-01-01
Duodenal perforations during diagnostic upper endoscopy are rare; however, when therapeutic techniques are performed, the reported incidence is as great as 2.8%. Surgical repair is usually mandated, but it is associated with significant morbidity and mortality. To compare closure of duodenal perforations by using an over-the-scope clip (OTSC) with a surgical closure. Randomized, controlled animal study. Animal facility laboratory. Domestic pigs (24 females). Large (10-mm) duodenal perforations were created by using an endoscopic needle-knife. The animals were randomly assigned to either open surgical repair (n=12) or endoscopic closure by using the OTSC system (n=12). Pressurized leak tests were performed during necropsy. One major bleed occurred because of a liver injury during creation of the duodenotomy. Mean time for endoscopic closure was 5 minutes (range, 3-8 min; SD +/- 2). No complications occurred during any of the closure procedures. At necropsy, all OTSC and surgical closures demonstrated complete sealing of duodenotomy sites. Pressurized leak tests demonstrated a mean burst pressure of 166 mm Hg (range, 80-260; SD +/- 65) for OTSC closures and 143 mm Hg (range, 30-300, SD +/- 83) for surgical sutures. Ex vivo intact duodenal specimens exhibited a mean burst pressure of 247 mm Hg (range, 200-300; SD +/- 35), which was significantly higher compared with in vivo OTSC and surgical closures (P < .01). There were no significant differences between burst pressures of OTSC and surgical closures (P = .461). Nonsurvival setting. Endoscopic closure of duodenal perforations by using the OTSC system is comparable with surgical closure in a nonsurvival porcine model. This technique is easy to perform and seems suitable for repairing duodenal perforations. 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Lishko, Polina; Clapham, David E.; Navarro, Betsy; Kirichok, Yuriy
2014-01-01
Sperm intracellular pH and calcium concentration ([Ca2+]i) are two central factors that control sperm activity within the female reproductive tract. As such, the ion channels of the sperm plasma membrane that alter intracellular sperm [Ca2+] and pH play important roles in sperm physiology and the process of fertilization. Indeed, sperm ion channels regulate sperm motility, control sperm chemotaxis toward the egg in some species, and may trigger the acrosome reaction. Until recently, our understanding of these important molecules was rudimentary due to the inability to patch-clamp spermatozoa and directly record the activity of these ion channels under voltage clamp. Recently, we overcame this technical barrier and developed a method for reproducible application of the patch-clamp technique to mouse and human spermatozoa. This chapter covers important aspects of application of the patch-clamp technique to spermatozoa, such as selection of the electrophysiological equipment, isolation of spermatozoa for patch-clamp experiments, formation of the gigaohm seal with spermatozoa, and transition into the whole-cell mode of recording. We also discuss potential pitfalls in application of the patch-clamp technique to flagellar ion channels. PMID:23522465
Munakata, Mitsutoshi; Tsuchiya, Shigeru
2008-10-01
A considerable amount of 7-aminoclonazepam (ACZP), a major metabolite of clonazepam (CZP), is present in the brain during CZP treatment, yet the pharmacological properties of ACZP remain unknown. We investigated the effects of ACZP on the GABA(A) receptor-mediated currents (I(GABA)) in neurons from the nucleus reticularis thalami (NRT) of the rat, using a nystatin-perforated patch technique. Neurons in which CZP (10 nM) exerted prominent augmentation (>100% augmentation) of I(GABA), which comprised 32% of the neurons tested, were included for the analysis of ACZP. In these neurons, ACZP augmented I(GABA), which was blocked by 10 microM flumazenil, a benzodiazepine receptor (BZR) antagonist. The half-maximal effective concentration of ACZP was 124 nM, whereas that of CZP was 1.8 nM. The maximal enhancements induced by ACZP and CZP were 38% and 170%, respectively. In neurons from the ventrobasal complex of the thalamus, the effect of ACZP was negligible. Our results suggest that ACZP was a weak partial BZR agonist and that ACZP may competitively modify the effect of CZP, leading to clinical consequences for patients with high levels of ACZP.
A neuronal mechanism of propofol-induced central respiratory depression in newborn rats.
Kashiwagi, Masanori; Okada, Yasumasa; Kuwana, Shun-Ichi; Sakuraba, Shigeki; Ochiai, Ryoichi; Takeda, Junzo
2004-07-01
The neural mechanisms of propofol-induced central respiratory depression remain poorly understood. In the present study, we studied these mechanisms and the involvement of gamma-aminobutyric acid (GABA)A receptors in propofol-induced central respiratory depression. The brainstem and the cervical spinal cord of 1- to 4-day-old rats were isolated, and preparations were maintained in vitro with oxygenated artificial cerebrospinal fluid. Rhythmic inspiratory burst activity was recorded from the C4 spinal ventral root. The activity of respiratory neurons in the ventrolateral medulla was recorded using a perforated patch-clamp technique. We found that bath-applied propofol decreased C4 inspiratory burst rate, which could be reversed by the administration of a GABAA antagonist, bicuculline. Propofol caused resting membrane potentials to hyperpolarize and suppressed the firing of action potentials in preinspiratory and expiratory neurons. In contrast, propofol had little effect on resting membrane potentials and action potential firing in inspiratory neurons. Our findings suggest that the depressive effects of propofol are, at least in part, mediated by the agonistic action of propofol on GABAA receptors. It is likely that the GABAA receptor-mediated hyperpolarization of preinspiratory neurons serves as the neuronal basis of propofol-induced respiratory depression in the newborn rat.
Cellular mechanisms underlying spatiotemporal features of cholinergic retinal waves
Ford, Kevin J.; Félix, Aude L.; Feller, Marla B.
2012-01-01
Prior to vision, a transient network of recurrently connected cholinergic interneurons, called starburst amacrine cells (SACs), generates spontaneous retinal waves. Despite an absence of robust inhibition, cholinergic retinal waves initiate infrequently and propagate within finite boundaries. Here we combine a variety of electrophysiological and imaging techniques and computational modeling to elucidate the mechanisms underlying these spatial and temporal properties of waves in developing mouse retina. Waves initiate via rare spontaneous depolarizations of SACs. Waves propagate through recurrent cholinergic connections between SACs and volume release of ACh as demonstrated using paired recordings and a cell-based ACh optical sensor. Perforated patch recordings and two-photon calcium imaging reveal that individual SACs have slow afterhyperpolarizations that induce SACs to have variable depolarizations during sequential waves. Using a computational model in which the properties of SACs are based on these physiological measurements, we reproduce the slow frequency, speed, and finite size of recorded waves. This study represents a detailed description of the circuit that mediates cholinergic retinal waves and indicates that variability of the interneurons that generate this network activity may be critical for the robustness of waves across different species and stages of development. PMID:22262883
Inhibition of Kv7/M Channel Currents by the Local Anesthetic Chloroprocaine.
Zhang, Fan; Cheng, Yanxin; Li, Hong; Jia, Qingzhong; Zhang, Hailin; Zhao, Senming
2015-01-01
Chloroprocaine is a local ester anesthetic, producing excellent sensory block in clinical use. The Kv7/M potassium channel plays an important role in the control of neuronal excitability. In this study, we investigated the effects of the local anesthetic chloroprocaine on Kv7/M channels as well as the effect of retigabine on chloroprocaine-induced seizures. A perforated whole-cell patch technique was used to record Kv7 currents from HEK293 cells and M-type currents from rat dorsal root ganglion (DRG) neurons. Chloroprocaine produced a number of effects on Kv7.2/Kv7.3 currents, including a lowering of current amplitudes, a rightward shift in the voltage-dependent activation curves, and a slowing of channel activation. Chloroprocaine had a more selective inhibitory effect on the homomeric Kv7.3 and heteromeric Kv7.2/Kv7.3 channels than on the homomeric Kv7.2 channel. Chloroprocaine also inhibited native M channel currents and induced a depolarization of the DRG neuron membrane potential. Taken together, the findings indicate that chloroprocaine concentration dependently inhibited Kv7/M channel currents. © 2015 S. Karger AG, Basel.
Endovenous ablation of refluxing saphenous and perforating veins.
Proebstle, Thomas; van den Bos, Renate
2017-05-01
Since the end of the nineties endovenous thermal ablation and more recently non-thermal, non-tumescent techniques have been developed and improved. Until now, because of their favourable side effect profile in conjunction to sustained efficacy, in many countries they already replaced high ligation and stripping in the treatment of refluxing saphenous veins as well as for treatment of perforators and selected tributaries. Now, studies and comparative trials are available with long-term follow-ups for most of the techniques, providing valid data on occlusion and reflux rates, side effect profiles, and health related quality of life.
[Colonic perforation during colonoscopy. 100 cases].
Hureau, J; Avtan, L; Germain, M; Blanc, D; Chaussade, G
1992-01-01
The analysis of 100 cases of colon perforation during colposcopic examinations highly demonstrates such a statement. The perforation risk during colposcopies is generally of the order of 0.2% for a diagnosis coloscopy. According to the statistic data used, it can reach 0.5 to 3% in therapy coloscopy. This is a risk inherent to the technique used. It is thus required to analyse the causes and take the appropriate measures to reduce it to a minimum. Mortality due to such a complication remains high (14%), i.e about 0.015 to 0.1% (#2/10000) of all colposcopies. In 11% of the patients, serious sequelae are to be observed. This demonstrates the significance of the medico-legal problem set by these perforations during colposcopies. The whole personnel responsibility can be involved: colposcopist, surgeon, anesthetist and hospital unit.
Gunnarsson, Gudjon L.; Børsen-Koch, Mikkel; Nielsen, Henrik T.; Salzberg, Andrew
2015-01-01
Summary: We present our experience of bilateral total breast reconstruction using a double-sided extended thoracodorsal artery perforator propeller flap in a case series of 10 patients. Reconstruction was successfully achieved in all cases with few complications. The median time for surgery was 275 minutes (200–330), and the average implant size used was 350 cm3 (195–650). We demonstrate how the extended thoracodorsal artery perforator propeller flap allows for a swift and reliable direct to implant bilateral total breast reconstruction in a simple setting and is a valuable adjunct to our armamentarium of techniques for single-stage bilateral breast reconstruction. PMID:26180736
Reducible dictionaries for single image super-resolution based on patch matching and mean shifting
NASA Astrophysics Data System (ADS)
Rasti, Pejman; Nasrollahi, Kamal; Orlova, Olga; Tamberg, Gert; Moeslund, Thomas B.; Anbarjafari, Gholamreza
2017-03-01
A single-image super-resolution (SR) method is proposed. The proposed method uses a generated dictionary from pairs of high resolution (HR) images and their corresponding low resolution (LR) representations. First, HR images and the corresponding LR ones are divided into patches of HR and LR, respectively, and then they are collected into separate dictionaries. Afterward, when performing SR, the distance between every patch of the input LR image and those of available LR patches in the LR dictionary is calculated. The minimum distance between the input LR patch and those in the LR dictionary is taken, and its counterpart from the HR dictionary is passed through an illumination enhancement process. By this technique, the noticeable change of illumination between neighbor patches in the super-resolved image is significantly reduced. The enhanced HR patch represents the HR patch of the super-resolved image. Finally, to remove the blocking effect caused by merging the patches, an average of the obtained HR image and the interpolated image obtained using bicubic interpolation is calculated. The quantitative and qualitative analyses show the superiority of the proposed technique over the conventional and state-of-art methods.
Correlation of open cell-attached and excised patch clamp techniques.
Filipovic, D; Hayslett, J P
1995-11-01
The excised patch clamp configuration provides a unique technique for some types of single channel analyses, but maintenance of stable, long-lasting preparations may be confounded by rundown and/or rapid loss of seal. Studies were performed on the amiloride-sensitive Na+ channel, located on the apical surface of A6 cells, to determine whether the nystatin-induced open cell-attached patch could serve as an alternative configuration. Compared to excised inside-out patches, stable preparations were achieved more readily with the open cell-attached patch (9% vs. 56% of attempts). In both preparations, the current voltage (I-V) relation was linear, current amplitudes were equal at opposite equivalent clamped voltages, and Erev was zero in symmetrical Na+ solutions, indicating similar Na+ activities on the cytosolic and external surfaces of the patch. Moreover, there was no evidence that nystatin altered channel activity in the patch because slope conductance (3-4pS) and Erev (75 mV), when the bath was perfused with a high K:low Na solution (ENa = 80 mV), were nearly equal in both patch configurations. Our results therefore indicate that the nystatin-induced open cell-attached patch can serve as an alternative approach to the excised inside-out patch when experiments require modulation of univalent ions in the cytosol.
Kim, Jeong Tae; Kim, Youn Hwan; Ghanem, Ali M
2015-11-01
Complex defects present structural and functional challenges to reconstructive surgeons. When compared to multiple free flaps or staged reconstruction, the use of chimeric flaps to reconstruct such defects have many advantages such as reduced number of operative procedures and donor site morbidity as well as preservation of recipient vessels. With increased popularity of perforator flaps, chimeric flaps' harvest and design has benefited from 'perforator concept' towards more versatile and better reconstruction solutions. This article discusses perforator based chimeric flaps and presents a practice based classification system that incorporates the perforator flap concept into "Perforator Chimerism". The authors analyzed a variety of chimeric patterns used in 31 consecutive cases to present illustrative case series and their new classification system. Accordingly, chimeric flaps are classified into four types. Type I: Classical Chimerism, Type II: Anastomotic Chimerism, Type III: Perforator Chimerism and Type IV Mixed Chimerism. Types I on specific source vessel anatomy whilst Type II requires microvascular anastomosis to create the chimeric reconstructive solution. Type III chimeric flaps utilizes the perforator concept to raise two components of tissues without microvascular anastomosis between them. Type IV chimeric flaps are mixed type flaps comprising any combination of Types I to III. Incorporation of the perforator concept in planning and designing chimeric flaps has allowed safe, effective and aesthetically superior reconstruction of complex defects. The new classification system aids reconstructive surgeons and trainees to understand chimeric flaps design, facilitating effective incorporation of this important reconstructive technique into the armamentarium of the reconstruction toolbox. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Standardizing the Delivery of 20 μL of Hapten During Patch Testing.
Selvick, Annika; Stauss, Kari; Strobush, Katrina; Taylor, Lauren; Picard, Alexandra; Doll, Andrea; Reeder, Margo
2016-01-01
The current method for patch test tray assembly requires hand dispensing a small volume of hapten onto chambers. Because of human error, this technique produces inaccurate and inconsistent results. The recommended volume of hapten for patch testing using Finn Chambers is 20 μL. The aims of this study were to create a device that standardizes the delivery of 20 μL and to compare it with the current hand dispensing technique. A device, named the Revolution, was created using the SolidWorks program. Five nurses in our Contact Dermatitis Clinic were asked to load 10 Finn Chambers using the current technique and also using the Revolution. Assembly time, volume of petrolatum, and accuracy of placement were measured. After the 3 trials, the nurses completed a survey on the 2 methods. The amount of petrolatum dispensed using the current technique ranged from 16 to 85 μL, with an average amount of 41.39 μL. The Revolution design dispensed an average of 19.78 μL. The current hand dispensing technique does not allow for accurate and consistent dispensing of 20 μL for patch testing. In contrast, the Revolution is an accurate and consistent device that can help standardize the patch testing method.
A rabbit ventricular action potential model replicating cardiac dynamics at rapid heart rates.
Mahajan, Aman; Shiferaw, Yohannes; Sato, Daisuke; Baher, Ali; Olcese, Riccardo; Xie, Lai-Hua; Yang, Ming-Jim; Chen, Peng-Sheng; Restrepo, Juan G; Karma, Alain; Garfinkel, Alan; Qu, Zhilin; Weiss, James N
2008-01-15
Mathematical modeling of the cardiac action potential has proven to be a powerful tool for illuminating various aspects of cardiac function, including cardiac arrhythmias. However, no currently available detailed action potential model accurately reproduces the dynamics of the cardiac action potential and intracellular calcium (Ca(i)) cycling at rapid heart rates relevant to ventricular tachycardia and fibrillation. The aim of this study was to develop such a model. Using an existing rabbit ventricular action potential model, we modified the L-type calcium (Ca) current (I(Ca,L)) and Ca(i) cycling formulations based on new experimental patch-clamp data obtained in isolated rabbit ventricular myocytes, using the perforated patch configuration at 35-37 degrees C. Incorporating a minimal seven-state Markovian model of I(Ca,L) that reproduced Ca- and voltage-dependent kinetics in combination with our previously published dynamic Ca(i) cycling model, the new model replicates experimentally observed action potential duration and Ca(i) transient alternans at rapid heart rates, and accurately reproduces experimental action potential duration restitution curves obtained by either dynamic or S1S2 pacing.
Vitse, J; Bekara, F; Bertheuil, N; Sinna, R; Chaput, B; Herlin, C
2017-02-01
Current data on upper extremity propeller flaps are poor and do not allow the assessment of the safety of this technique. A systematic literature review was conducted searching PubMed, EMBASE, and the Cochrane Library electronic databases, and the selection process was adapted from the preferred reporting items for systematic reviews and meta-analysis statement. The final analysis included ten relevant articles involving 117 flaps. The majority of flaps were used for the hand, distal wrist, and elbow. The radial artery perforator and ulnar artery perforator were the most frequently used flaps. The were 7% flaps with venous congestion and 3% with complete necrosis. No difference in complications rate was found for different flaps sites. Perforator-based propeller flaps appear to be an interesting procedure for covering soft tissue defects involving the upper extremities, even for large defects, but the procedure requires experience and close monitoring. II.
Mishiro, Tsuyoshi; Shibagaki, Kotaro; Matsuda, Kayo; Fukuyama, Chika; Okada, Mayumi; Mikami, Hironobu; Izumi, Daisuke; Yamashita, Noritsugu; Okimoto, Eiko; Fukuda, Naoki; Aimi, Masahito; Fukuba, Nobuhiko; Oshima, Naoki; Takanashi, Toshihiro; Matsubara, Takeshi; Ishimura, Norihisa; Ishihara, Shunji; Kinoshita, Yoshikazu
2016-08-01
In recent years, treatment techniques in which polyglycolic acid sheets are applied to various situations with fibrin glue have exhibited great clinical potential, and previous studies have reported safety and efficacy. We describe closure of a non-healing perforated duodenal ulcer with the use of a polyglycolic acid sheet and fibrin glue in an elderly patient who was not a candidate for surgery.
Zhou, Tuantuan; Gao, Wanlin; Wang, Qiang; Umar, Ahmad
2018-05-01
Herein, we report the facile synthesis of high-aspect ratio perforated Co3O4 nanowires derived from cobalt-carbonate-hydroxide (Co(CO3)0.5(OH) 0.11H2O) nanowires. The Co(CO3)0.5(OH) 0.11H2O nanowires were synthesized by simple hydrothermal process at 120 °C while annealing of such nanowires at 400 °C leads the formation of perforated Co3O4 nanowires. The prepared nanowires were characterized by several techniques which confirmed the high aspect ratio and well-crystallinity for the synthesized nanowires. For application point of view, the prepared perforated Co3O4 nanowires were used as efficient electrode material to fabricate highly sensitive and selective hydrazine chemical sensor. The electrochemical impedance spectroscopy (EIS) technique was employed to confirm the successful modification of the electrode. The key parameters of chemical sensor, such as detection limit, sensitivity, and linear range, have been systematically explored. The fabricated hydrazine sensor displayed a rather low detection limit of 4.52 μM (S/N = 3), a good sensitivity of 25.70 μA · mM-1, and a wide linear range of 16.97-358.34 μM.
Ettinger, Kyle S; Alexander, Amy E; Arce, Kevin
2018-04-10
Virtual surgical planning (VSP), computer-aided design and computer-aided modeling, and 3-dimensional printing are 3 distinct technologies that have become increasingly used in head and neck oncology and microvascular reconstruction. Although each of these technologies has long been used for treatment planning in other surgical disciplines, such as craniofacial surgery, trauma surgery, temporomandibular joint surgery, and orthognathic surgery, its widespread use in head and neck reconstructive surgery remains a much more recent event. In response to the growing trend of VSP being used for the planning of fibular free flaps in head and neck reconstruction, some surgeons have questioned the technology's implementation based on its inadequacy in addressing other reconstructive considerations beyond hard tissue anatomy. Detractors of VSP for head and neck reconstruction highlight its lack of capability in accounting for multiple reconstructive factors, such as recipient vessel selection, vascular pedicle reach, need for dead space obliteration, and skin paddle perforator location. It is with this premise in mind that the authors report on a straightforward technique for anatomically localizing peroneal artery perforators during VSP for osteocutaneous fibular free flaps in which bone and a soft tissue skin paddle are required for ablative reconstruction. The technique allows for anatomic perforator localization during the VSP session based solely on data existent at preoperative computed tomographic angiography (CTA); it does not require any modifications to preoperative clinical workflows. It is the authors' presumption that many surgeons in the field are unaware of this planning capability within the context of modern VSP for head and neck reconstruction. The primary purpose of this report is to introduce and further familiarize surgeons with the technique of CTA perforator localization as a method of improving intraoperative fidelity for VSP of osteocutaneous fibular free flaps. Copyright © 2018. Published by Elsevier Inc.
A Novel Ex Vivo Training Model for Acquiring Supermicrosurgical Skills Using a Chicken Leg.
Cifuentes, Ignacio J; Rodriguez, José R; Yañez, Ricardo A; Salisbury, María C; Cuadra, Álvaro J; Varas, Julian E; Dagnino, Bruno L
2016-11-01
Background Supermicrosurgery is a technique used for dissection and anastomosis of submillimeter diameter vessels. This technique requires precise hand movements and superb eye-hand coordination, making continuous training necessary. Biological in vivo and ex vivo models have been described for this purpose, the latter being more accessible and cost-effective. The aim of this study is to present a new ex vivo training model using a chicken leg. Methods In 28 chicken legs, an anatomical study was performed. An intramuscular perforator vessel was identified and dissected. Arterial diameters of 0.7, 0.5, and 0.3 mm were identified and consistency of the perforator was assessed. In additional 10 chicken legs, 25 submillimeter arteries were anastomosed using this perforator vessel. Five arteries of 0.3 and 10 of 0.5 mm were anastomosed with nylon 11-0 and 12-0 sutures. Intravascular stent (IVaS) technique and open guide (OG) technique were used in 0.5-mm arteries. A total of 10 arteries of 0.7 mm were anastomosed using 10-0 sutures in a conventional fashion. Dissection and anastomosis time were recorded and patency was tested. Results We were able to identify 0.7 to 0.3 mm diameter arteries in all the specimens and confirm the consistency of the perforator. The median time for dissection was 13.4 minutes. The median time for anastomosis was 32.3 minutes for 0.3-mm arteries, 24.3 minutes for 0.5-mm arteries using IVaS, 29.5 minutes for the OG technique, and 20.9 minutes for the 0.7 mm diameter arteries. All the anastomoses were permeable. Conclusion Due to its consistent and adequate diameter vessels, this model is adequate for training supermicrosurgical skills. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
NASA Astrophysics Data System (ADS)
Molinario, G.
2015-12-01
Conflict in the Democratic Republic of Congo (DRC) and neighboring countries has caused the displacement of people internally and internationally sometimes leading to drastic changes in the impact that traditional slash and burn shifting cultivation has on the forest ecosystem. In other areas, the lack of infrastructure and governance has isolated and protected areas of core forest from large scale exploitation. Observing specific patterns of forest fragmentation caused either by the expansion of existing rural complex areas or of isolated forest perforations has allowed us to track the differential growth of the human footprint throughout forested area of the country during the period 2000-2010. Our methodological approach involved the development of a model of shifting cultivation and forest fragmentation in which spatial rules applied morphological image processing to the Forets d'Afrique Central Evaluee par Teledetection (FACET) product. The result is a disaggregated classification of the primary forest into patch, edge, perforated, fragmented and core forest subtypes which we subsequently re-aggregated into homogenous anthropogenic macro-areas of rural complex and isolated forest perforations. We tracked how subsequent forest loss observed in 2005 and 2010 grew or shrunk these areas, presumably with differential impacts on the forest ecosystem. Using this approach we were able to map forest degradation by contextualizing the contribution of forest loss to change in different types of areas, highlighting how it can be greatly underestimated by a non contextualized per-pixel assessment of forest cover loss.
Laparoscopic Repair for Perforated Peptic Ulcer in Children.
Reusens, Helena; Dassonville, Martine; Steyaert, Henri
2017-06-01
Introduction A perforated peptic ulcer (PPU) is a rare but major complication of gastroduodenal peptic ulcer disease. Literature is scarce on this subject in the pediatric population and most articles describe a surgical treatment by laparotomy. We aim to review all our cases of pediatric PPU treated over the past 16 years and compare these to literature to deduce potential benefits and disadvantages regarding laparoscopic treatment of PPU in children. Materials and Methods A retrospective study of all cases of PPU treated at the Lenval Hospital in Nice (France) and the Queen Fabiola University Hospital for Children in Brussels (Belgium) between 1998 and 2015 was performed. Results A total of five children were treated for PPU (2 females). The average age was 11 years (range, 3-17). All of them were surgically treated with laparoscopic simple suture of the perforation and placement of an omental patch. There were no mortalities, no conversions, and no extra-abdominal complications or wound dehiscences. Mean operating time was 78.6 minutes (range, 70-115 minutes). Mean duration of intravenous treatment was 6 days (range, 4-12 days). One reintervention was performed for abdominal infection. In one patient, an abdominal drain was left in place for 2 days. The mean time before refeeding was 3.4 days (range, 3-4 days) and mean length of stay was 12 days (range, 7-30 days). Conclusion Laparoscopic repair is safe and feasible for PPU and should be the gold standard for treatment of PPU in children. Georg Thieme Verlag KG Stuttgart · New York.
Successful embolization of iatrogenic ruptured coronary artery using Onyx: a new technique.
Asouhidou, I; Katsaridis, V
2014-12-01
Iatrogenic perforation of coronary artery is rare during percutaneous coronary intervention (PCI); however the complications are life-threatening. Patients in this clinical setting may be treated either by stent placement, closure of the perforation with fibrin glue or coils, or with emergency bypass surgery. Onyx, a new material that has been used successfully in cerebral arteries, represents a new and safe alternative. The advantage of Onyx is that it is easily injected through a microcatheter and it allows for a longer injection time having also the ability to reach difficult anatomical locations. We present the first case of successful embolization of a right coronary artery perforation during coronary angiography using Onyx.
Laparoscopic repair for perforated peptic ulcer disease.
Sanabria, Alvaro; Villegas, Maria Isabel; Morales Uribe, Carlos Hernando
2013-02-28
Perforated peptic ulcer is a common abdominal disease that is treated by surgery. The development of laparoscopic surgery has changed the way to treat such abdominal surgical emergencies. The results of some clinical trials suggest that laparoscopic surgery could be a better strategy than open surgery in the correction of perforated peptic ulcer but the evidence is not strongly in favour for or against this intervention. To measure the effect of laparoscopic surgical treatment versus open surgical treatment in patients with a diagnosis of perforated peptic ulcer in relation to abdominal septic complications, surgical wound infection, extra-abdominal complications, hospital length of stay and direct costs. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) on The Cochrane Library (2004, Issue 2), PubMed/MEDLINE (1966 to July 2004), EMBASE (1985 to November 2004) and LILACS (1988 to November 2004) as well as the reference lists of relevant articles. Searches in all databases were updated in December 2009 and January 2012. We did not confine our search to English language publications. Randomized clinical trials comparing laparoscopic surgery versus open surgery for the repair of perforated peptic ulcer using any mechanical method of closure (suture, omental patch or fibrin sealant). Primary outcome measures included proportion of septic and other abdominal complications (surgical site infection, suture leakage, intra-abdominal abscess, postoperative ileus) and extra-abdominal complications (pulmonary). Secondary outcomes included mortality, time to return to normal diet, time of nasogastric aspiration, hospital length-of-stay and costs. Outcomes were summarized by reporting odds ratios (ORs) and 95% confidence intervals (CIs), using the fixed-effect model. We included three randomized clinical trials of acceptable quality. We found no statistically significant differences between laparoscopic and open surgery in the proportion of abdominal septic complications (OR 0.66; 95% CI 0.30 to 1.47), pulmonary complications (OR 0.43; 95% CI 0.17 to 1.12) or number of septic abdominal complications (OR 0.60; 95% CI 0.32 to 1.15). Heterogeneity was significant for pulmonary complications and operating time. This review suggests that a decrease in septic abdominal complications may exist when laparoscopic surgery is used to correct perforated peptic ulcer. However, it is necessary to perform more randomized controlled trials with a greater number of patients to confirm such an assumption, guaranteeing a long learning curve for participating surgeons. With the information provided it could be said that laparoscopic surgery results are not clinically different from those of open surgery.
Aortic valve repair with autologous pericardial patch.
Lausberg, Henning F; Aicher, Diana; Langer, Frank; Schäfers, Hans-Joachim
2006-08-01
Isolated aortic valve repair (AVR) has been gaining increasing interest in recent times. Results of isolated aortic valve repair have been reported to be variable. Various techniques have been utilized. We analyzed our experience with isolated valve repair using autologous pericardial patch plasty and compared the results to an age-matched collective with aortic valve repair without the use of additional material. Between January 1997 and June 2005, pericardial patch plasty of the aortic valve was performed in 42 patients (PATCH). During the same period, 42 patients after AVR without the use of additional material were age matched (NO-PATCH). Mean age in both groups was 52 years with a majority of male patients (PATCH ratio, 3.7:1; NO-PATCH ratio, 5:1). Valve anatomy was similar in both groups. All patients were followed by echocardiography for a cumulative follow-up of 2341 patient months (mean 28+/-23 months). No patient died in the hospital in neither group. The average systolic gradient was 5.9+/-2.2 mmHg in PATCH and 4.8+/-2.1 mmHg in NO-PATCH; p=0.17). Freedom from aortic regurgitation > or = II degrees was 87.8% in PATCH and 95.0% in NO-PATCH after 5 years (p=0.21). Freedom from reoperation was 97.6% in PATCH and 97.4% in NO-PATCH (p=0.96). Aortic regurgitation can be treated effectively by aortic valve repair using pericardial patch plasty. The functional results are satisfactory. With the application of this technique also more complex pathologies of the aortic valve can be addressed adequately thus extending the concept of valve preservation in patients with aortic regurgitation.
Pritz, Michael B
2014-11-01
Perforator and secondary branch origin in relation to the neck of cerebral, saccular bifurcation aneurysms were analyzed. These two features were considered important for treatment. From a series of microsurgically clipped saccular cerebral aneurysms, 142 bifurcation aneurysms had detailed imaging studies and operative records that could be analyzed. The incidence of perforator origin from the aneurysm neck was as follows: basilar, 1/15 (7%); internal carotid artery bifurcation, 4/23 (17%); main stem of the middle cerebral artery/secondary branch of the middle cerebral artery, 6/52 (12%); anterior communicating artery region, 5/46 (11%); and distal bifurcation vessels, 0/6 (0%). Aneurysms arising from the anterior communicating artery between the anterior cerebral arteries had a high incidence of perforator origin from the aneurysm neck. The location of secondary branch origin from the aneurysm neck varied depending on the aneurysm group. Perforator origin from the aneurysm neck was infrequent. A subgroup of anterior communicating artery region aneurysms had a high incidence of perforator origin from the aneurysm neck. Although protection of these neck perforators will be difficult, their identification may be even more challenging. Secondary branch origin from the aneurysm neck varied depending on the aneurysm group. Advanced endovascular techniques are needed to obliterate aneurysms in which the secondary branch(es) arise from the aneurysm neck. If this is not possible, craniotomy and clip ligation will be required if complete aneurysm obliteration is the goal. Copyright © 2014 Elsevier Inc. All rights reserved.
Smith, Lane F; Smith, Lane F
2015-05-01
There continues to be controversy about performing abdominoplasty concurrently with abdominal liposuction. The concern is that liposuction on the already vascularly compromised abdominal flap will lead to increased complications and flap necrosis. The central abdomen is supplied by the epigastric system. If perforator vessels from this system are spared, the blood supply to the abdomen can be spared and liposuction should be able to be safely performed on the elevated abdominal flap. The purpose of this study was to evaluate the safety of abdominoplasty with concurrent abdominal liposuction when a perforator vessel is spared. A standard abdominoplasty was performed, sparing one or two perforator vessels from the deep superior epigastric artery system. A retrospective chart review of 300 consecutive patients who underwent abdominoplasty surgery combined with concurrent abdominal liposuction was performed. Complications, total volume of abdominal liposuction, and results were reviewed. The overall complication rate was 17.3 percent (52 patients). Sixteen percent (48 patients) suffered minor complications and 1.3 percent (four patients) suffered major complications. Abdominoplasty can be combined safely with concurrent abdominal liposuction when a perforator vessel is spared. The combination of concurrent liposuction with abdominoplasty showed no increase in complication rates when a perforator vessel was spared. The perforator vessels are located consistently in a 2-cm radius located 4 cm from the midline and 6 cm from the subcostal margin. The potential advantages of abdominoplasty with concurrent liposuction include a better postoperative cosmetic result. Therapeutic, IV.
Luo, Jiaquan; Wu, Chunyang; Huang, Zhongren; Pan, Zhimin; Li, Zhiyun; Zhong, Junlong; Chen, Yiwei; Han, Zhimin; Cao, Kai
2017-04-01
This is a cadaver specimen study to confirm new pedicle screw (PS) entry point and trajectory for subaxial cervical PS insertion. To assess the accuracy of the lateral vertebral notch-referred PS insertion technique in subaxial cervical spine in cadaver cervical spine. Reported morphometric landmarks used to guide the surgeon in PS insertion show significant variability. In the previous study, we proposed a new technique (as called "notch-referred" technique) primarily based on coronal multiplane reconstruction images (CMRI) and cortical integrity after PS insertion in cadavers. However, the PS position in cadaveric cervical segment was not confirmed radiologically. Therefore, the difference between the pedicle trajectory and the PS trajectory using the notch-referred technique needs to be illuminated. Twelve cadaveric cervical spines were conducted with PS insertion using the lateral vertebral notch-referred technique. The guideline for entry point and trajectory for each vertebra was established based on the morphometric data from our previous study. After 3.5-mm diameter screw insertion, each vertebra was dissected and inspected for pedicle trajectory by CT scan. The pedicle trajectory and PS trajectory were measured and compared in axial plane. The perforation rate was assessed radiologically and was graded from ideal to unacceptable: Grade 0 = screw in pedicle; Grade I = perforation of pedicle wall less than one-fourth of the screw diameter; Grade II = perforation more than one-fourth of the screw diameter but less than one-second; Grade III = perforation more than one-second outside of the screw diameter. In addition, pedicle width between the acceptable and unacceptable screws was compared. A total of 120 pedicle screws were inserted. The perforation rate of pedicle screws was 78.3% in grade 0 (excellent PS position), 10.0% in grade I (good PS position), 8.3% in grade II (fair PS position), and 3.3% in grade III (poor PS position). The overall accepted accuracy of pedicle screws was 96.7% (Grade 0 + Grade I + Grade II), and only 3.3% had critical breach. There was no statistical difference between the pedicle trajectory and PS trajectory (p > 0.05). Compared to the pedicle width (4.4 ± 0.7 mm) in acceptably inserted screw, the unacceptably screw is 3.2 ± 0.3 mm which was statistically different (p < 0.05). The accuracy of the notch-referred PS insertion in cadaveric subaxial cervical spine is satisfactory.
Malhotra, Monika; Sharma, Jai Bhagwan; Wadhwa, Leena; Arora, Raksha
2004-08-01
To assess the glove perforation rate, efficacy of double gloving, effect of duration of surgery, expertise of surgeon and operative urgency on the glove perforation rate in obstetrical and gynecologic operations. From February to September 2002, double glove protocol was made necessary for all major obstetrical and gynecologic procedures. The operating surgeon, first and second assistant were included in the study. Gloves damage was noted (overt by inspection, occult by hydroinsufflation technique). Of the 156 procedures included in study, 32 procedures were performed (all emergency operations) single-gloved because surgeons found double gloving clumsy (56%), made it difficult to tie knots due to lack of dexterity (24%), or were too tight (20%). One thousand one hundred and twenty single gloves were examined after each procedure by hydroinsufflation. The overall perforation rate was 13.6% (single versus double outer gloves, 13.8% versus l3.2%, P > 0.05). Matching perforations were found in six cases (4.6%). Thus, the protection offered by double gloves was 95.4% even if the outer gloves were perforated. Four inner gloves had preexisting perforations. Sixty unused gloves checked similarly revealed a perforation rate of 1.6%. Emergency cases had higher perforation rate compared to elective surgeries (16.6% versus 10.8%, P < 0.00 1). Surgeries lasting for more than 40 min had a higher perforation rate compared to those finished in less than or equal to 40 min (18.6% versus 7.6%, P < 0.001). The middle finger of the left hand was the most commonly involved. The surgeon, first assistant and second assistant were involved in 73.6, 23.3 and 3.2% cases, respectively. Double gloving offers considerable protection against exposure to contaminants in the blood and body fluids of the patient and should be made routine, especially in developing countries where HIV, hepatitis B and C are widely prevalent. Double gloving should be made mandatory in emergency procedures, which have a higher perforation rate due to operative urgency, and gloves should be changed in operations lasting for more than 40 min to ensure integrity of barrier.
A circularly polarized Ka-band stacked patch antenna with increased gain
NASA Technical Reports Server (NTRS)
Zawadzki, M.
2002-01-01
Stacking layers of microstrip patches is a technique often used to improve the bandwidth of a patch antenna, but rarely used to increase its gain. The work presented here scales the three-layer S-band work done in to Ka-band.
Arbitrarily shaped dual-stacked patch antennas: A hybrid FEM simulation
NASA Technical Reports Server (NTRS)
Gong, Jian; Volakis, John L.
1995-01-01
A dual-stacked patch antenna is analyzed using a hybrid finite element - boundary integral (FE-BI) method. The metallic patches of the antenna are modeled as perfectly electric conducting (PEC) plates stacked on top of two different dielectric layers. The antenna patches may be of any shape and the lower patch is fed by a coaxial cable from underneath the ground plane or by an aperture coupled microstrip line. The ability of the hybrid FEM technique for the stacked patch antenna characterization will be stressed, and the EM coupling mechanism is also discussed with the aid of the computed near field patterns around the patches.
Microfabricated Patch Clamp Electrodes for Improved Ion Channel Protein Measurements
NASA Astrophysics Data System (ADS)
Klemic, James; Klemic, Kathryn; Reed, Mark; Sigworth, Frederick
2002-03-01
Ion channels are trans-membrane proteins that underlie many cell functions including hormone and neurotransmitter release, muscle contraction and cell signaling cascades. Ion channel proteins are commonly characterized via the patch clamp method in which an extruded glass tube containing ionic solution, manipulated by an expert technician, is brought into contact with a living cell to record ionic current through the cell membrane. Microfabricated planar patch electrodes, micromolded in the silicone elastomer poly-dimethylsiloxane (PDMS) from microlithographically patterned structures, have been developed that improve on this method. Microfabrication techniques allow arrays of patch electrodes to be fabricated, increasing the throughput of the measurement technique. Planar patch electrodes readily allow the automation of cell sealing, further increasing throughput. Microfabricated electrode arrays may be readily integrated with microfluidic structures to allow fast, in situ solution exchange. Miniaturization of the electrode geometry should increase both the signal to noise and the bandwidth of the measurement. Microfabricated patch electrode arrays have been fabricated and measurements have been taken.
Mahdizadeh Barzoki, Zahra; Emam-Djomeh, Zahra; Mortazavian, Elaheh; Akbar Moosavi-Movahedi, Ali; Rafiee Tehrani, M
2016-11-01
The present study was performed to optimise the formulation of a muco-adhesive buccal patch for insulin nanoparticles (NPs) delivery. Insulin NPs were synthesised by an ionic gelation technique using N-di methyl ethyl chitosan cysteine (DMEC-Cys) as permeation enhancer biopolymer, tripolyphosphate (TPP) and insulin. Buccal patches were developed by solvent-casting technique using chitosan and gelatine as muco-adhesive polymers. Optimised patches were embedded with 3 mg of insulin-loaded NPs with a homogeneous distribution of NPs in the muco-adhesive matrix, which displayed adequate physico-mechanical properties. The drug release characteristics, release mechanism and kinetics were investigated. Data fitting to Peppas equation with a correlation coefficient indicated that the mechanism of drug release followed an anomalous transport that means drug release was afforded through drug diffusion along with polymer erosion. In vitro drug release, release kinetics, physical and mechanical studies for all patch formulations reflected the ideal characteristics of this buccal patch for the delivery of insulin NPs.
Changing patterns in the surgical treatment of perforated duodenal ulcer - single centre experience.
Budzyński, Piotr; Pędziwiatr, Michał; Grzesiak-Kuik, Agata; Natkaniec, Michał; Major, Piotr; Matłok, Maciej; Stanek, Maciej; Wierdak, Mateusz; Migaczewski, Marcin; Pisarska, Magdalena; Budzyński, Andrzej
2015-09-01
Although the surgical treatment of patients with perforated duodenal ulcer is the method of choice, the introduction of effective pharmacotherapy has changed the surgical strategy. Nowadays less extensive procedures are chosen more frequently. The introduction of laparoscopic procedures had a significant impact on treatment results. To present our experience in the treatment of perforated duodenal ulcer in two periods, by comparing open radical anti-ulcer procedures with laparoscopic ulcer repair. The analysis covered patients operated on for perforated duodenal ulcer. Two groups of patients were compared. Group 1 included 245 patients operated on in the period 1980-1994 with a traditional method (pyloroplasty + vagotomy) before introduction of proton pump inhibitors (PPI). Group 2 included 106 patients treated in the period 2000-2014 with the laparoscopic technique supplemented with PPI therapy. Groups were compared in terms of patients' demographic structure, operative time, complication rate and mortality. The mean operative time in group 1 was shorter than in group 2 (p < 0.0001). Complications were noted in 57 (23.3%) patients in group 1 and 14 (13.5%) patients in group 2 (p = 0.0312). Reoperation was necessary in 13 (5.3%) cases in group 1 and in 5 cases in group 2 (p = 0.8179). The mortality rate in group 1 was significantly higher than in group 2 (10.2% vs. 2.8%, p = 0.0192). In group 1, median length of hospital stay was 9 days and differed significantly from group 2 (6 days, p < 0.0001). Within the last 30 years, significant changes in treatment of perforated peptic ulcer (PPU) have occurred, mainly related to abandoning routine radical anti-ulcer procedures and replacing the open technique with minimally invasive surgery. Thus it was possible to improve treatment results by reducing complication and mortality rates, and shortening the length of hospital stay. Although the laparoscopic operation is longer, it improves outcomes. In the authors' opinion, in each patient with suspected peptic ulcer perforation, laparoscopy should be the method of choice.
NASA Technical Reports Server (NTRS)
Simons, Rainee N.
2002-01-01
The paper presents a novel on-wafer, antenna far field pattern measurement technique for microelectromechanical systems (MEMS) based reconfigurable patch antennas. The measurement technique significantly reduces the time and the cost associated with the characterization of printed antennas, fabricated on a semiconductor wafer or dielectric substrate. To measure the radiation patterns, the RF probe station is modified to accommodate an open-ended rectangular waveguide as the rotating linearly polarized sampling antenna. The open-ended waveguide is attached through a coaxial rotary joint to a Plexiglas(Trademark) arm and is driven along an arc by a stepper motor. Thus, the spinning open-ended waveguide can sample the relative field intensity of the patch as a function of the angle from bore sight. The experimental results include the measured linearly polarized and circularly polarized radiation patterns for MEMS-based frequency reconfigurable rectangular and polarization reconfigurable nearly square patch antennas, respectively.
Closure technique after carotid endarterectomy influences local hemodynamics.
Harrison, Gareth J; How, Thien V; Poole, Robert J; Brennan, John A; Naik, Jagjeeth B; Vallabhaneni, S Rao; Fisher, Robert K
2014-08-01
Meta-analysis supports patch angioplasty after carotid endarterectomy (CEA); however, studies indicate considerable variation in practice. The hemodynamic effect of a patch is unclear and this study attempted to elucidate this and guide patch width selection. Four groups were selected: healthy volunteers and patients undergoing CEA with primary closure, trimmed patch (5 mm), or 8-mm patch angioplasty. Computer-generated three-dimensional models of carotid bifurcations were produced from transverse ultrasound images recorded at 1-mm intervals. Rapid prototyping generated models for flow visualization studies. Computational fluid dynamic studies were performed for each model and validated by flow visualization. Mean wall shear stress (WSS) and oscillatory shear index (OSI) maps were created for each model using pulsatile inflow at 300 mL/min. WSS of <0.4 Pa and OSI >0.3 were considered pathological, predisposing to accretion of intimal hyperplasia. The resultant WSS and OSI maps were compared. The four groups comprised 8 normal carotid arteries, 6 primary closures, 6 trimmed patches, and seven 8-mm patches. Flow visualization identified flow separation and recirculation at the bifurcation increased with a patch and was related to the patch width. Computational fluid dynamic identified that primary closure had the fewest areas of low WSS or elevated OSI but did have mild common carotid artery stenoses at the proximal arteriotomy that caused turbulence. Trimmed patches had more regions of abnormal WSS and OSI at the bifurcation, but 8-mm patches had the largest areas of deleteriously low WSS and high OSI. Qualitative comparison among the four groups confirmed that incorporation of a patch increased areas of low WSS and high OSI at the bifurcation and that this was related to patch width. Closure technique after CEA influences the hemodynamic profile. Patching does not appear to generate favorable flow dynamics. However, a trimmed 5-mm patch may offer hemodynamic benefits over an 8-mm patch and may be the preferred option. Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Kishore, R; Sankar, T Bavani; Anandi, A; Nedunchezhian, S; Murugan, Valarmathy
2016-10-01
Perforators are those which connect the superficial and deep venous system either directly to main veins or indirectly through the muscular and soleal venous plexus. The emergence of minimally invasive techniques like ambulatory phlebectomy (AP) and foam sclerotherapy (FS) has led to increasing interest about the appropriate therapy for the treatment of isolated perforator incompetence. There have been no studies which have compared the effectiveness of these in-office procedures in isolated perforator incompetence due to the low prevalence of cases. The primary goal of this study is to compare the clinical parameters (return to normal activity, primary symptom relief), functional parameters (procedure time, change in disease severity, course of venous ulcer), and duplex parameters (recurrence in treated veins, complete occlusion of treated veins) in the management of leg varicosities having isolated primary perforator incompetence by ambulatory phlebectomy and duplex guided foam sclerotherapy. Though the procedure time was shorter with FS than AP, the other parameters of primary symptom relief such as change in disease severity, faster healing of venous ulcer, complete occlusion of treated veins in follow-up duplex examination, and lower recurrence of treated veins are better with AP than FS. In conclusion, the interruption of perforators is effective in decreasing the symptoms of chronic venous insufficiency and for the rapid healing of ulcers. The interruption of the incompetent perforating veins appears to be essential to decrease ambulatory venous hypertension. It is apparent from this study that ambulatory phlebectomy stands distinct with enormous benefits and serves as a superior alternative to foam sclerotherapy in treating patients with isolated perforator incompetence.
Rediscovering sperm ion channels with the patch-clamp technique
Kirichok, Yuriy; Lishko, Polina V.
2011-01-01
Upon ejaculation, mammalian spermatozoa have to undergo a sequence of physiological transformations within the female reproductive tract that will allow them to reach and fertilize the egg. These include initiation of motility, hyperactivation of motility and perhaps chemotaxis toward the egg, and culminate in the acrosome reaction that permits sperm to penetrate the protective vestments of the egg. These physiological responses are triggered through the activation of sperm ion channels that cause elevations of sperm intracellular pH and Ca2+ in response to certain cues within the female reproductive tract. Despite their key role in sperm physiology and their absolute requirement for the process of fertilization, sperm ion channels remain poorly understood due to the extreme difficulty in application of the patch-clamp technique to spermatozoa. This review covers the topic of sperm ion channels in the following order: first, we discuss how the intracellular Ca2+ and pH signaling mediated by sperm ion channels controls sperm behavior during the process of fertilization. Then, we briefly cover the history of the methodology to study sperm ion channels, which culminated in the recent development of a reproducible whole-cell patch-clamp technique for mouse and human cells. We further discuss the main approaches used to patch-clamp mature mouse and human spermatozoa. Finally, we focus on the newly discovered sperm ion channels CatSper, KSper (Slo3) and HSper (Hv1), identified by the sperm patch-clamp technique. We conclude that the patch-clamp technique has markedly improved and shifted our understanding of the sperm ion channels, in addition to revealing significant species-specific differences in these channels. This method is critical for identification of the molecular mechanisms that control sperm behavior within the female reproductive tract and make fertilization possible. PMID:21642646
Grzelka, Katarzyna; Kurowski, Przemysław; Gawlak, Maciej; Szulczyk, Paweł
2017-01-01
The medial prefrontal cortex (mPFC) receives dense noradrenergic projections from the locus coeruleus. Adrenergic innervation of mPFC pyramidal neurons plays an essential role in both physiology (control of memory formation, attention, working memory, and cognitive behavior) and pathophysiology (attention deficit hyperactivity disorder, posttraumatic stress disorder, cognitive deterioration after traumatic brain injury, behavioral changes related to addiction, Alzheimer's disease and depression). The aim of this study was to elucidate the mechanism responsible for adrenergic receptor-mediated control of the resting membrane potential in layer V mPFC pyramidal neurons. The membrane potential or holding current of synaptically isolated layer V mPFC pyramidal neurons was recorded in perforated-patch and classical whole-cell configurations in slices from young rats. Application of noradrenaline (NA), a neurotransmitter with affinity for all types of adrenergic receptors, evoked depolarization or inward current in the tested neurons irrespective of whether the recordings were performed in the perforated-patch or classical whole-cell configuration. The effect of noradrenaline depended on β 1 - and not α 1 - or α 2 -adrenergic receptor stimulation. Activation of β 1 -adrenergic receptors led to an increase in inward Na + current through hyperpolarization-activated cyclic nucleotide-gated (HCN) channels, which carry a mixed Na + /K + current. The protein kinase A- and C-, glycogen synthase kinase-3β- and tyrosine kinase-linked signaling pathways were not involved in the signal transduction between β 1 -adrenergic receptors and HCN channels. The transduction system operated in a membrane-delimited fashion and involved the βγ subunit of G-protein. Thus, noradrenaline controls the resting membrane potential and holding current in mPFC pyramidal neurons through β 1 -adrenergic receptors, which in turn activate HCN channels via a signaling pathway involving the βγ subunit.
Grzelka, Katarzyna; Kurowski, Przemysław; Gawlak, Maciej; Szulczyk, Paweł
2017-01-01
The medial prefrontal cortex (mPFC) receives dense noradrenergic projections from the locus coeruleus. Adrenergic innervation of mPFC pyramidal neurons plays an essential role in both physiology (control of memory formation, attention, working memory, and cognitive behavior) and pathophysiology (attention deficit hyperactivity disorder, posttraumatic stress disorder, cognitive deterioration after traumatic brain injury, behavioral changes related to addiction, Alzheimer’s disease and depression). The aim of this study was to elucidate the mechanism responsible for adrenergic receptor-mediated control of the resting membrane potential in layer V mPFC pyramidal neurons. The membrane potential or holding current of synaptically isolated layer V mPFC pyramidal neurons was recorded in perforated-patch and classical whole-cell configurations in slices from young rats. Application of noradrenaline (NA), a neurotransmitter with affinity for all types of adrenergic receptors, evoked depolarization or inward current in the tested neurons irrespective of whether the recordings were performed in the perforated-patch or classical whole-cell configuration. The effect of noradrenaline depended on β1- and not α1- or α2-adrenergic receptor stimulation. Activation of β1-adrenergic receptors led to an increase in inward Na+ current through hyperpolarization-activated cyclic nucleotide-gated (HCN) channels, which carry a mixed Na+/K+ current. The protein kinase A- and C-, glycogen synthase kinase-3β- and tyrosine kinase-linked signaling pathways were not involved in the signal transduction between β1-adrenergic receptors and HCN channels. The transduction system operated in a membrane-delimited fashion and involved the βγ subunit of G-protein. Thus, noradrenaline controls the resting membrane potential and holding current in mPFC pyramidal neurons through β1-adrenergic receptors, which in turn activate HCN channels via a signaling pathway involving the βγ subunit. PMID:29209170
Hocaoğlu, Emre
2014-01-01
Prefabrication of supraclavicular skin provides a useful source for flaps congruent with the face skin. Among various vascular sources that have been used for this purpose, anterolateral thigh fascia seems to represent a greater value because of having a long and strong vascular pedicle and negligible donor-site morbidity. In this regard, we present a technical report on using the lateral circumflex femoral artery perforator flap harvest technique in preparing an anterolateral thigh fascia flap for the prefabrication of the supraclavicular skin. The technique proved successful in resurfacing the facial skin of a young female patient with a giant congenital melanocytic hairy nevus on the left side of her face.
Scalise, Alessandro; Tartaglione, Caterina; Bolletta, Elisa; Pierangeli, Marina; Di Benedetto, Giovanni
2015-08-01
We report the case of a 50-year-old paraplegic man with a complicated grade III/IV ischiatic pressure sore treated with a propeller flap based on the first perforator of the profunda femoris artery. Our aim was to surgically reconstruct an ischiatic pressure sore in a patient with ankylosis using a fasciocutaneous perforator propeller flap obtained from the posterior region of the thigh. Our decision to perform a profunda femoris artery perforator propeller flap reconstruction was mainly due to the anatomical contiguity of the flap with the site of the lesion and the good quality of the skin harvested from the posterior region of the thigh. The use of the perforator fasciocutaneous flap represents a muscle-sparing technique, providing a better long-term result in surgical reconstruction. The choice of the 180-degree propeller flap was due to its ability to provide a good repair of the pressure ulcer and to pass over the ischiatic prominence in the patient in the forced decubitus position. The operatory course did not present any kind of complication. Using this reconstructive treatment, we have obtained complete coverage of the ischiatic pressure sore.
Propeller Perforator Flaps in Distal Lower Leg: Evolution and Clinical Applications
2012-01-01
Simple or complex defects in the lower leg, and especially in its distal third, continue to be a challenging task for reconstructive surgeons. A variety of flaps were used in the attempt to achieve excellence in form and function. After a long evolution of the reconstructive methods, including random pattern flaps, axial pattern flaps, musculocutaneous flaps and fasciocutaneous flaps, the reappraisal of the works of Manchot and Salmon by Taylor and Palmer opened the era of perforator flaps. This era began in 1989, when Koshima and Soeda, and separately Kroll and Rosenfield described the first applications of such flaps. Perforator flaps, whether free or pedicled, gained a high popularity due to their main advantages: decreasing donor-site morbidity and improving aesthetic outcome. The use as local perforator flaps in lower leg was possible due to a better understanding of the cutaneous circulation, leg vascular anatomy, angiosome and perforasome concepts, as well as innovations in flaps design. This review will describe the evolution, anatomy, flap design, and technique of the main distally pedicled propeller perforator flaps used in the reconstruction of defects in the distal third of the lower leg and foot. PMID:22783507
Casey, M.C.; Robertson, I.; Waters, P.S.; Hanaghan, J.; Khan, W.; Barry, K.
2014-01-01
INTRODUCTION No consensus exists regarding definitive management of colonic perforation in Ehlers–Danlos syndrome (EDS), with various authors advocating different operative techniques. Spontaneous colonic perforation is a recognised complication of vascular-type EDS (type IV), with many reported cases in the literature. No such cases have been reported concerning classical-type EDS (type I/II). PRESENTATION OF CASE A 55-year-old male with a family history of EDS presented with acute lower abdominal pain and signs of localised peritonitis. Following resuscitation, computerised tomography identified perforation of a sigmoid diverticulum with localised intraperitoneal air. Considering the potential complications associated with laparotomy in a patient with EDS, a trial of conservative management was undertaken including image-guided drainage of a mesenteric abscess. Intensive care monitoring, nutritional support and intravenous antibiotics also facilitated successful non-operative management. Following discharge, molecular studies confirmed COL5A1 mutation, and a diagnosis of classical Ehlers–Danlos syndrome was established. DISCUSSION This is the first reported case of successful conservative management of colonic diverticular perforation in a patient with classical Ehlers–Danlos syndrome. CONCLUSION EDS is highly significant in the surgical context, with the causative genetic factors serving to further complicate the course of surgical intervention. In the absence of consensus regarding best surgical management, due consideration should be given to non-operative management of benign colonic perforation. PMID:24534685
Evaluation on Compression Properties of Different Shape and Perforated rHDPE in Concrete Structures
NASA Astrophysics Data System (ADS)
Yuhazri, M. Y.; Hafiz, K. M.; Myia, Y. Z. A.; Jia, C. P.; Sihombing, H.; Sapuan, S. M.; Badarulzaman, N. A.
2017-10-01
The purpose of this study was to develop a concrete structure by incorporating waste HDPE plastic as the main reinforcement material and cement as the matrix via standard casting technique. There are eight different shapes of rHDPE reinforcing structure were used to investigate the compression properties of produced concrete composites. Experimental result shown that the highest shape in compressive strength of rHDPE reinforcing structure were the concrete with the addition of X-perforated beam (18.22 MPa), followed by X-beam (17.7 MPa), square perforated tube (17.54 MPa), round tube (17.42 MPa) and round perforated tube (16.69 MPa). In terms of their compressive behavior, the average concrete containing rHDPE reinforcement was successfully improved by 6 % of the mechanical characteristic compared to control concrete. It is shown that the addition of waste plastic as reinforcement structure can provide better compressive strength based on their shape and pattern respectively.
Occult glove perforation during ophthalmic surgery.
Apt, L; Miller, K M
1992-01-01
We examined the latex surgical gloves used by 56 primary surgeons in 454 ophthalmic surgical procedures performed over a 7-month period. Of five techniques used to detect pinholes, air inflation with water submersion and compression was found to be the most sensitive, yielding a 6.80% prevalence in control glove pairs and a 21.8% prevalence in postoperative study glove pairs, for a 15.0% incidence of surgically induced perforations (P = 0.000459). The lowest postoperative perforation rate was 11.4% for cataract and intraocular lens surgery, and the highest was 41.7% for oculoplastic procedures. Factors that correlated significantly with the presence of glove perforations as determined by multiple logistic regression analysis were oculoplastic and pediatric ophthalmology and strabismus surgical procedures, surgeon's status as a fellow in training, operating time, and glove size. The thumb and index finger of the nondominant hand contained the largest numbers of pinholes. These data suggest strategies for reducing the risk of cross-infection during ophthalmic surgery. PMID:1494836
Rapid and controllable perforation of carbon nanotubes by microwave radiation
NASA Astrophysics Data System (ADS)
Ojaghi, Neda; Mokhtarifar, Maryam; Sabaghian, Zahra; Arab, Hamed; Maghrebi, Morteza; Baniadam, Majid
2018-05-01
This study presents a new controlled approach to deep perforation of millimeter-long carbon nanotube arrays (CNTAs) by fast oxidative cutting. The approach is based on decorating CNTAs with silver (Ag) nanoparticles, followed by heating Ag-decorated CNTAs with microwave radiation (2.48 GHz, 300 W). The perforation was evaluated using different techniques such as transmission electron microscopy, X-ray photoelectron spectroscopy, and Brunauer-Emmett-Teller method. The results of the oxidation of carbonaceous materials indicated that the relative amount of oxygen functional groups increased without total oxidation of carbon up to 60 s. After 60 s, the amount of functional groups decreased as the total oxidation started suddenly. Afterwards, at around 120 and 420 s, the oxidation of Ag-decorated CNTAs reached the point of total perforation and total cutting, respectively. Though carbon decomposition terminated at around 420 s, the total pore volume and surface area increased continuously. This was attributed to the steady growth of Ag nanoparticles located between CNTAs.
Force-controlled patch clamp of beating cardiac cells.
Ossola, Dario; Amarouch, Mohamed-Yassine; Behr, Pascal; Vörös, János; Abriel, Hugues; Zambelli, Tomaso
2015-03-11
From its invention in the 1970s, the patch clamp technique is the gold standard in electrophysiology research and drug screening because it is the only tool enabling accurate investigation of voltage-gated ion channels, which are responsible for action potentials. Because of its key role in drug screening, innovation efforts are being made to reduce its complexity toward more automated systems. While some of these new approaches are being adopted in pharmaceutical companies, conventional patch-clamp remains unmatched in fundamental research due to its versatility. Here, we merged the patch clamp and atomic force microscope (AFM) techniques, thus equipping the patch-clamp with the sensitive AFM force control. This was possible using the FluidFM, a force-controlled nanopipette based on microchanneled AFM cantilevers. First, the compatibility of the system with patch-clamp electronics and its ability to record the activity of voltage-gated ion channels in whole-cell configuration was demonstrated with sodium (NaV1.5) channels. Second, we showed the feasibility of simultaneous recording of membrane current and force development during contraction of isolated cardiomyocytes. Force feedback allowed for a gentle and stable contact between AFM tip and cell membrane enabling serial patch clamping and injection without apparent cell damage.
Planar patch clamp for neuronal networks--considerations and future perspectives.
Bosca, Alessandro; Martina, Marzia; Py, Christophe
2014-01-01
The patch-clamp technique is generally accepted as the gold standard for studying ion channel activity allowing investigators to either "clamp" membrane voltage and directly measure transmembrane currents through ion channels, or to passively monitor spontaneously occurring intracellular voltage oscillations. However, this resulting high information content comes at a price. The technique is labor-intensive and requires highly trained personnel and expensive equipment. This seriously limits its application as an interrogation tool for drug development. Patch-clamp chips have been developed in the last decade to overcome the tedious manipulations associated with the use of glass pipettes in conventional patch-clamp experiments. In this chapter, we describe some of the main materials and fabrication protocols that have been developed to date for the production of patch-clamp chips. We also present the concept of a patch-clamp chip array providing high resolution patch-clamp recordings from individual cells at multiple sites in a network of communicating neurons. On this chip, the neurons are aligned with the aperture-probes using chemical patterning. In the discussion we review the potential use of this technology for pharmaceutical assays, neuronal physiology and synaptic plasticity studies.
Free style perforator based propeller flaps: Simple solutions for upper extremity reconstruction!
Panse, Nikhil; Sahasrabudhe, Parag
2014-01-01
The introduction of perforator flaps by Koshima et al. was met with much animosity in the plastic surgery fraternity. The safety concerns of these flaps following the intentional twist of the perforators have prevented widespread adoption of this technique. Use of perforator based propeller flaps in the lower extremity is gradually on the rise, but their use in upper extremity reconstruction is infrequently reported, especially in the Indian subcontinent. We present a retrospective series of 63 free style perforator flaps used for soft tissue reconstruction of the upper extremity from November 2008 to June 2013. Flaps were performed by a single surgeon for various locations and indications over the upper extremity. Patient demographics, surgical indication, defect features, complications and clinical outcome are evaluated and presented as an uncontrolled case series. 63 free style perforator based propeller flaps were used for soft tissue reconstruction of 62 patients for the upper extremity from November 2008 to June 2013. Of the 63 flaps, 31 flaps were performed for trauma, 30 for post burn sequel, and two for post snake bite defects. We encountered flap necrosis in 8 flaps, of which there was complete necrosis in 4 flaps, and partial necrosis in four flaps. Of these 8 flaps, 7 needed a secondary procedure, and one healed secondarily. Although we had a failure rate of 12-13%, most of our failures were in the early part of the series indicative of a learning curve associated with the flap. Free style perforator based propeller flaps are a reliable option for coverage of small to moderate sized defects. Therapeutic IV.
Sadigh, Parviz L; Chang, Li-Ren; Hsieh, Ching-Hua; Feng, Wen-Jui; Jeng, Seng-Feng
2014-09-01
The trapezius myocutaneous flap is an established reconstructive option in head and neck cases The authors present their experience with 10 trapezius perforator flaps, all raised using a freestyle technique of perforator dissection, to successfully reconstruct both local and distant soft-tissue defects. Ten patients underwent soft-tissue reconstruction using trapezius perforator flaps. After mapping the perforator with a handheld Doppler device at the intersection of a horizontal line drawn 6 to 8 cm inferior to the scapular spine and a vertical line drawn 8 to 9 cm lateral to the midline of the back, perforator flaps were raised in a freestyle fashion, with complete preservation of the trapezius muscle. The flap can be pedicled into local defects or transferred as a free flap. Six flaps were elevated as pedicled flaps and four were transferred as free flaps. Flap size ranged from 6 × 4 cm to 25 × 15 cm. The pedicle length ranged from 4 to 14 cm. The pedicle originated from the dorsal scapular artery. In one case, the authors converted from a pedicled flap to a free flap secondary to insufficient pedicle length. All donor sites were closed directly. The follow-up period ranged from 4 months to 4 years. All of the flaps survived completely with no major complications, and no patients developed any shoulder dysfunction. The trapezius perforator flap is a reliable and versatile reconstructive option that can be used to repair both local and distant soft-tissue defects. The donor-site morbidity is minimal. Therapeutic, IV.
Smith, Lane F.
2015-01-01
Background: There continues to be controversy about performing abdominoplasty concurrently with abdominal liposuction. The concern is that liposuction on the already vascularly compromised abdominal flap will lead to increased complications and flap necrosis. The central abdomen is supplied by the epigastric system. If perforator vessels from this system are spared, the blood supply to the abdomen can be spared and liposuction should be able to be safely performed on the elevated abdominal flap. The purpose of this study was to evaluate the safety of abdominoplasty with concurrent abdominal liposuction when a perforator vessel is spared. Methods: A standard abdominoplasty was performed, sparing one or two perforator vessels from the deep superior epigastric artery system. A retrospective chart review of 300 consecutive patients who underwent abdominoplasty surgery combined with concurrent abdominal liposuction was performed. Complications, total volume of abdominal liposuction, and results were reviewed. Results: The overall complication rate was 17.3 percent (52 patients). Sixteen percent (48 patients) suffered minor complications and 1.3 percent (four patients) suffered major complications. Conclusions: Abdominoplasty can be combined safely with concurrent abdominal liposuction when a perforator vessel is spared. The combination of concurrent liposuction with abdominoplasty showed no increase in complication rates when a perforator vessel was spared. The perforator vessels are located consistently in a 2-cm radius located 4 cm from the midline and 6 cm from the subcostal margin. The potential advantages of abdominoplasty with concurrent liposuction include a better postoperative cosmetic result. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV. PMID:25919250
What Do We Know About Component Separation Techniques for Abdominal Wall Hernia Repair?
Scheuerlein, Hubert; Thiessen, Andreas; Schug-Pass, Christine; Köckerling, Ferdinand
2018-01-01
The component separation technique (CST) was introduced to abdominal wall reconstruction to treat large, complex hernias. It is very difficult to compare the published findings because of the vast number of technical modifications to CST as well as the heterogeneity of the patient population operated on with this technique. The main focus of the literature search conducted up to August 2017 in Medline and PubMed was on publications reporting comparative findings as well as on systematic reviews in order to formulate statements regarding the various CSTs. CST without mesh should no longer be performed because of too high recurrence rates. Open anterior CST has too high a surgical site occurrence rate and henceforth should only be conducted as endoscopic and perforator sparing anterior CST. Open posterior CST and posterior CST with transversus abdominis release (TAR) produce better results than open anterior CST. To date, no significant differences have been found between endoscopic anterior, perforator sparing anterior CST and posterior CST with transversus abdominis release. Robot-assisted posterior CST with TAR is the latest, very promising alternative. The systematic use of biologic meshes cannot be recommended for CST. CST should always be performed with mesh as endoscopic or perforator sparing anterior or posterior CST. Robot-assisted posterior CST with TAR is the latest development.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Warpinski, N.R.
At present, the only viable technique for accurately measuring stresses at depth in a borehole is hydraulic fracturing. These have been termed microfracs because very small amounts of fluid are injected at low flow rates into the formation. When the well is shut in, the pressure immediately drops from the injection pressure to the instantaneous shut-in pressure (ISIP) which is approximately equal to sigma/sub min/. In general, the ISIP can be measured quite accurately in open holes. For most oil and gas applications, however, it is impossible or impractical to conduct these tests in an open-hole environment. The effects ofmore » the casing, cement annulus, explosive perforation damage, and random performation orientation are impossible to predict theoretically, and laboratory tests are usually conducted under nonrealistic conditions. A set of in situ experiments was conducted to evaluate the accuracy and reliability of this technique, to aid in the selection of an optimum perforation schedule, and to develop a diagnostic capability from the pressure response.« less
Determining the minimum in situ stress from hydraulic fracturing through perforations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Warpinski, N.R.
Hydraulic fracture stress measurements have been performed through perforations at depths from 1310 to 2470 m at the US Department of Energy's Multiwell Experiment site. The results of over sixty stress tests conducted through perforations have shown that small-volume hydraulic fractures generally provide an accurate, reproducible measurement of the minimum in situ stress. However, unusual behavior can occur in some tests and techniques to evaluate the behavior are suggested. Unclear instantaneous shut-in pressures, which are found on occasional tests, are difficult to evaluate, but the problem appears to be a complex stress state; reprocessing the data using log-log or othermore » functions does not necessarily provide the correct stress value. The possible error in such tests should be assessed from the original pressure-time data and not the reprocessing techniques. Stress results show that the stress distribution is dependent on lithology at this site; mudstones, shales and other nonreservoir rocks generally have a near-lithostatic stress, while sandstones have a considerably lower minimum stress value. 30 refs., 18 figs., 4 tabs.« less
Mechanisms of the palmitoylcarnitine-induced response in vascular endothelial cells.
Taki, H; Muraki, K; Imaizumi, Y; Watanabe, M
1999-09-01
The mechanisms of Ca2+ mobilization induced by palmitoylcarnitine (Palcar) in rabbit aortic endothelial cells (ETCs) were examined using electrophysiological techniques. The results obtained were compared with those induced by acetylcholine (ACh). When a rabbit aortic muscle preparation with an intact endothelium was treated with 10 microM Palcar, the ACh-induced relaxation was markedly attenuated, whereas endothelium-independent relaxation caused by sodium nitroprusside was not affected. Under perforated-patch whole-cell-clamp conditions, the application of Palcar over the concentration range 0.3 and 10 microM elicited a slowly activating outward current (IPalcar-out), whereas ACh induced a rapidly activating outward current (IACh). A potassium channel blocker, 4-aminopyridine, significantly inhibited both IPalcar-out and IACh. Removal of external Ca2+ almost abolished IPalcar-out. Under the same conditions, however, IACh remained transient. Addition of cation channel blockers SK&F96365 and La3+ inhibited IPalcar-out more effectively than IACh. Application of staurosporine, an inhibitor of protein kinase C, affected neither IACh nor IPalcar-out. In contrast, treatment of ETCs with pertussis toxin (PTX) reduced IACh and almost abolished IPalcar-out. These findings demonstrate that, in ETCs, Palcar induces Ca2+ influx via the activation of PTX-sensitive GTP-binding protein, leading to the activation of Ca(2+)-dependent K+ current and hyperpolarization of the cell.
Changes in Inward Rectifier K+ Channels in Hepatic Stellate Cells During Primary Culture
Lee, Dong Hyeon; Kong, In Deok; Lee, Joong-Woo
2008-01-01
Purpose This study examined the expression and function of inward rectifier K+ channels in cultured rat hepatic stellate cells (HSC). Materials and Methods The expression of inward rectifier K+ channels was measured using real-time RT-PCR, and electrophysiological properties were determined using the gramicidin-perforated patch-clamp technique. Results The dominant inward rectifier K+ channel subtypes were Kir2.1 and Kir6.1. These dominant K+ channel subtypes decreased significantly during the primary culture throughout activation process. HSC can be classified into two subgroups: one with an inward-rectifying K+ current (type 1) and the other without (type 2). The inward current was blocked by Ba2+ (100 µM) and enhanced by high K+ (140 mM), more prominently in type 1 HSC. There was a correlation between the amplitude of the Ba2+-sensitive current and the membrane potential. In addition, Ba2+ (300 µM) depolarized the membrane potential. After the culture period, the amplitude of the inward current decreased and the membrane potential became depolarized. Conclusion HSC express inward rectifier K+ channels, which physiologically regulate membrane potential and decrease during the activation process. These results will potentially help determine properties of the inward rectifier K+ channels in HSC as well as their roles in the activation process. PMID:18581597
Das, Roby; Sureshkumar, Sathasivam; Sreenath, Gubbi S; Kate, Vikram
2016-01-01
Comparison of Helicobacter pylori eradication rates, side effects, compliance, cost, and ulcer recurrence of sequential therapy (ST) with that of concomitant therapy (CT) in patients with perforated duodenal ulcer following simple omental patch closure. Sixty-eight patients with perforated duodenal ulcer treated with simple closure and found to be H. pylori positive on three months follow-up were randomized to receive either ST or CT for H. pylori eradication. Urease test and Giemsa stain were used to assess for H. pylori eradication status. Follow-up endoscopies were done after 3 months, 6 months, and 1 year to evaluate the ulcer recurrence. H. pylori eradication rates were similar in ST and CT groups on intention-to-treat (ITT) analysis (71.43% vs 81.80%,P = 0.40). Similar eradication rates were also found in per-protocol (PP) analysis (86.20% vs 90%,P = 0.71). Ulcer recurrence rate in ST groups and CT groups at 3 months (17.14% vs 6.06%,P = 0.26), 6 months (22.86% vs 9.09%,P = 0.19), and at 1 year (25.71% vs 15.15%,P = 0.37) of follow-up was also similar by ITT analysis. Compliance and side effects to therapies were comparable between the groups. The most common side effects were diarrhoea and metallic taste in ST and CT groups, respectively. A complete course of ST costs Indian Rupees (INR) 570.00, whereas CT costs INR 1080.00. H. pylori eradication rates, side effects, compliance, cost, and ulcer recurrences were similar between the two groups. The ST was more economical compared with CT.
NASA Technical Reports Server (NTRS)
Miedema, H.; Henriksen, G. H.; Assmann, S. M.; Evans, M. L. (Principal Investigator)
1999-01-01
Application of patch clamp techniques to higher-plant cells has been subject to the limitation that the requisite contact of the patch electrode with the cell membrane necessitates prior enzymatic removal of the plant cell wall. Because the wall is an integral component of plant cells, and because cell-wall-degrading enzymes can disrupt membrane properties, such enzymatic treatments may alter ion channel behavior. We compared ion channel activity in enzymatically isolated protoplasts of Vicia faba guard cells with that found in membranes exposed by a laser microsurgical technique in which only a tiny portion of the cell wall is removed while the rest of the cell remains intact within its tissue environment. "Laser-assisted" patch clamping reveals a new category of high-conductance (130 to 361 pS) ion channels not previously reported in patch clamp studies on plant plasma membranes. These data indicate that ion channels are present in plant membranes that are not detected by conventional patch clamp techniques involving the production of individual plant protoplasts isolated from their tissue environment by enzymatic digestion of the cell wall. Given the large conductances of the channels revealed by laser-assisted patch clamping, we hypothesize that these channels play a significant role in the regulation of ion content and electrical signalling in guard cells.
LEANZA, V.; INTAGLIATA, E.; LEANZA, A.; FERLA, F.; LEANZA, G.; VECCHIO, R.
2014-01-01
Objectives To compare mini-sling and traditional tension-free operations for female stress urinary incontinence. Study design A systematic review of articles in the Literature published between 2002 and 2012, was conducted. A Pubmed search was performed. Primary outcomes were subjective and objective cure rates at 12 months comparing the three single-incision mini-slings techniques (TVT-Secur, MiniArc and Monarc systems) with the standard mid-urethral sling procedure TOT (Transobturator Vaginal Tape). Secondary outcomes included peri-operative (vaginal and/or bladder perforation, urine retention, urinary tract infection, bleeding, pain) and post-operative (mesh exposure, de novo urgency, and dyspareunia) complications. Results In term of objective cure rate at 12 month after surgery, it is evident that TOT at first, and MiniArc are the most effective procedures. The incidence of post-operative urgency and UTI was lower in TOT technique, while vaginal perforation was described in equal frequency both in TOT and in MiniArc procedures. The advantages of the three above described mini-invasive techniques seem to consist into lower cases of urinary retention, pain and bleeding. Furthermore, bladder perforation and bleeding are not described in the Literature for TVT-Secur and Monarc systems. Conclusions Some single-incision slings look promising and as effective as conventional sub-urethral slings at short term evaluation. However, at this moment a clear statement in favor of the widespread use of single-incision slings cannot be made. More studies must define the efficacy of these techniques. PMID:24841685
Timofeev, M E; Shapoval'yants, S G; Mikhalev, A I; Fedorov, E D; Konyukhov, G V
2016-01-01
To present the results of perforative duodenal ulcer surgical management using combination of endoscopic methods. The study included 279 patients with perforative duodenal ulcer who were operated for the period from 1996 to 2012. Diagnostics and medical tactics were based on developed in our clinic algorithm that includes use of both esophagogastroduodenoscopy and laparoscopy. Presented technique confirmed correct diagnosis, defined medical tactics and choice of surgery in 100% of cases. 67 patients had contraindications for laparoscopic suturing and underwent conventional operations. Herewith postoperative complications and death were observed in 25 (37.3%) and 9 (13.4%) patients respectively. Laparoscopic suturing was performed in 212 patients. Complications were diagnosed in 19 (8.9%) cases including 8 (3.7%) intraoperative and 11 (5.2%) postoperative. Deaths were absent.
Chae, Michael P; Hunter-Smith, David J; Rostek, Marie; Smith, Julian A; Rozen, Warren Matthew
2018-01-01
Optimizing preoperative planning is widely sought in deep inferior epigastric artery perforator (DIEP) flap surgery. One reason for this is that rates of fat necrosis remain relatively high (up to 35%), and that adjusting flap design by an improved understanding of individual perforasomes and perfusion characteristics may be useful in reducing the risk of fat necrosis. Imaging techniques have substantially improved over the past decade, and with recent advances in 3D printing, an improved demonstration of imaged anatomy has become available. We describe a 3D-printed template that can be used preoperatively to mark out a patient's individualized perforasome for flap planning in DIEP flap surgery. We describe this "perforasome template" technique in a case of a 46-year-old woman undergoing immediate unilateral breast reconstruction with a DIEP flap. Routine preoperative computed tomographic angiography was performed, with open-source software (3D Slicer, Autodesk MeshMixer and Cura) and a desktop 3D printer (Ultimaker 3E) used to create a template used to mark intra-flap, subcutaneous branches of deep inferior epigastric artery (DIEA) perforators on the abdomen. An individualized 3D printed template was used to estimate the size and boundaries of a perforasome and perfusion map. The information was used to aid flap design. We describe a new technique of 3D printing a patient-specific perforasome template that can be used preoperatively to infer perforasomes and aid flap design.
Hunter-Smith, David J.; Rostek, Marie; Smith, Julian A.; Rozen, Warren Matthew
2018-01-01
Summary: Optimizing preoperative planning is widely sought in deep inferior epigastric artery perforator (DIEP) flap surgery. One reason for this is that rates of fat necrosis remain relatively high (up to 35%), and that adjusting flap design by an improved understanding of individual perforasomes and perfusion characteristics may be useful in reducing the risk of fat necrosis. Imaging techniques have substantially improved over the past decade, and with recent advances in 3D printing, an improved demonstration of imaged anatomy has become available. We describe a 3D-printed template that can be used preoperatively to mark out a patient’s individualized perforasome for flap planning in DIEP flap surgery. We describe this “perforasome template” technique in a case of a 46-year-old woman undergoing immediate unilateral breast reconstruction with a DIEP flap. Routine preoperative computed tomographic angiography was performed, with open-source software (3D Slicer, Autodesk MeshMixer and Cura) and a desktop 3D printer (Ultimaker 3E) used to create a template used to mark intra-flap, subcutaneous branches of deep inferior epigastric artery (DIEA) perforators on the abdomen. An individualized 3D printed template was used to estimate the size and boundaries of a perforasome and perfusion map. The information was used to aid flap design. We describe a new technique of 3D printing a patient-specific perforasome template that can be used preoperatively to infer perforasomes and aid flap design. PMID:29464169
Tayong, Rostand B; Manyo Manyo, Jacques A; Siryabe, Emmanuel; Ntamack, Guy E
2018-04-01
This study deals with the deduction of parameters of Micro-Perforated Panel (MPP) systems from impedance tube data. It is shown that there is an ambiguity problem that exists between the MPP thickness and its open area ratio. This problem makes it difficult to invert the reflection coefficient data fitting and therefore to deduct the MPP parameters. A technique is proposed to reduce this ambiguity by using an equation that links the hole diameter to the open area ratio. Reflection coefficient data obtained for two specimens with different characteristics is employed for searching the MPP parameters using a simulated annealing algorithm. The results obtained demonstrate the effectiveness of this technique.
Characterisation of Ductile Prepregs
NASA Astrophysics Data System (ADS)
Pinto, F.; White, A.; Meo, M.
2013-04-01
This study is focused on the analysis of micro-perforated prepregs created from standard, off the shelf prepregs modified by a particular laser process to enhance ductility of prepregs for better formability and drapability. Fibres are shortened through the use of laser cutting in a predetermined pattern intended to maintain alignment, and therefore mechanical properties, yet increase ductility at the working temperature. The increase in ductility allows the product to be more effectively optimised for specific forming techniques. Tensile tests were conducted on several specimens in order to understand the ductility enhancement offered by this process with different micro-perforation patterns over standard prepregs. Furthermore, the effects of forming temperature was also analysed to assess the applicability of this material to hot draping techniques and other heated processes.
Supermicrosurgery: History, Applications, Training and the Future
Badash, Ido; Gould, Daniel J.; Patel, Ketan M.
2018-01-01
Supermicrosurgery, a technique of dissection and anastomosis of small vessels ranging from 0.3 to 0.8 mm, has revolutionized the fields of lymphedema treatment and soft tissue reconstruction. The technique offers several distinct benefits to microsurgeons, including the ability to manipulate small vessels that were previously inaccessible, and to minimize donor-site morbidity by dissecting short pedicles in a suprafascial plane. Thus, supermicrosurgery has become increasingly popular in recent years, and its applications have greatly expanded since it was first introduced 20 years ago. While supermicrosurgery was originally developed for procedures involving salvage of the digit tip, the technique is now routinely used in a wide variety of microsurgical cases, including lymphovenous anastomoses, vascularized lymph node transfers and perforator-to-perforator anastomoses. With continued experimentation, standardization of supermicrosurgical training, and high quality studies focusing on the outcomes of these novel procedures, supermicrosurgery can become a routine and valuable component of every microsurgeon’s practice. PMID:29740586
Optimization of a Circularly Polarized Patch Antenna for Two Frequency Bands
2015-09-01
the various techniques that can be used to improve the performance of a circularly polarized microstrip patch antenna . These adjustments include... microstrip antenna . 15. SUBJECT TERMS Patch Antenna , Circular Polarization 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT...Frequency Structural Simulator (HFSS) has allowed engineers to create scalable multiband microstrip antennas . Several factors were taken into
Reconstruction of Anterolateral Thigh Defects Using Perforator-Based Propeller Flaps.
Iida, Takuya; Yoshimatsu, Hidehiko; Koshima, Isao
2017-10-01
Usually, anterolateral thigh (ALT) defects with width more than 8 cm cannot be closed directly. Although several methods of using local flaps exist, flap mobility of these methods is limited. We introduced a perforator-based propeller flap for such reconstruction. Their maximal mobility, which minimizes their size, is their greatest advantage. In addition, we present our technical refinements including double-axes propeller flap, the use of indocyanine green real-time angiography, and supercharged propeller flap for safer flap transfer. Seven patients underwent perforator-based propeller flap reconstruction of ALT defects. Flaps were designed cranial or caudal to the defect according to the perforator locations. To maximize mobility, flaps were designed so that the perforator was located at the periphery and closer to the defect. After rotating the flap to the defect, indocyanine green angiography was performed to determine the need for supercharge. In all cases, all flaps survived completely. Defect size ranged from 12 × 11 cm to 18 × 16 cm, and flap size ranged from 7 × 5 cm to 15 × 7 cm. The number of perforators in the flap was 1 in 3 cases and 2 in 4 cases. Supercharging was performed in 3 cases. Donor-site complications, including gait disturbance, were not observed. This method achieves ALT defect closure with minimal donor-site morbidity and can provide prompt and aesthetically acceptable results. Indocyanine green real-time angiography and supercharging technique are also useful for safer and reliable flap transfer.
Sameem, Mojib; Au, Michael; Wood, Thomas; Farrokhyar, Forough; Mahoney, James
2012-07-01
Management of pressure sores poses a significant reconstructive challenge for plastic surgeons. Currently, there is no consensus on whether musculocutaneous, fasciocutaneous, or perforator-based flaps provide superior results for treating pressure sores. The following databases were searched: Cochrane Database of Systematic Reviews, Cochrane Central Register of Controlled Trials, LILACS (January of 1950 to November of 2010), MEDLINE (January of 1950 to November of 2010), and EMBASE (January of 1980 to November of 2010). Only articles reporting on the use of musculocutaneous, fasciocutaneous, and perforator-based flaps were included. The primary study outcomes were complication and recurrence rates. Fifty-five articles were included in the final analysis (kappa = 0.78). From this total, 28 were categorized as pertaining to musculocutaneous flaps, 13 studied fasciocutaneous flaps, and 14 evaluated perforator-based flaps. The authors' review revealed recurrence and complication rates of 8.9 and 18.6 percent, respectively, following reconstruction with musculocutaneous flaps, 11.2 and 11.7 percent following reconstruction with fasciocutaneous flaps, and 5.6 and 19.6 percent following reconstruction with perforator-based flaps. Overall, statistical analysis revealed no significant difference in complication or recurrence rates among these three techniques. The authors' review revealed that there was no statistically significant difference with regard to recurrence or complication rates among musculocutaneous, fasciocutaneous, or perforator-based flaps. This suggests that surgeons performing such reconstructive procedures may choose to consider the advantages of a specific approach rather than the complication and recurrence rates. Therapeutic, IV.
Patch-based image reconstruction for PET using prior-image derived dictionaries
NASA Astrophysics Data System (ADS)
Tahaei, Marzieh S.; Reader, Andrew J.
2016-09-01
In PET image reconstruction, regularization is often needed to reduce the noise in the resulting images. Patch-based image processing techniques have recently been successfully used for regularization in medical image reconstruction through a penalized likelihood framework. Re-parameterization within reconstruction is another powerful regularization technique in which the object in the scanner is re-parameterized using coefficients for spatially-extensive basis vectors. In this work, a method for extracting patch-based basis vectors from the subject’s MR image is proposed. The coefficients for these basis vectors are then estimated using the conventional MLEM algorithm. Furthermore, using the alternating direction method of multipliers, an algorithm for optimizing the Poisson log-likelihood while imposing sparsity on the parameters is also proposed. This novel method is then utilized to find sparse coefficients for the patch-based basis vectors extracted from the MR image. The results indicate the superiority of the proposed methods to patch-based regularization using the penalized likelihood framework.
Laser microsurgery of higher plant cell walls permits patch-clamp access
NASA Technical Reports Server (NTRS)
Henriksen, G. H.; Taylor, A. R.; Brownlee, C.; Assmann, S. M.; Evans, M. L. (Principal Investigator)
1996-01-01
Plasma membranes of guard cells in epidermal peels of Vicia faba and Commelina communis can be made accessible to a patch-clamp pipet by removing a small portion (1-3 micrometers in diameter) of the guard cell wall using a microbeam of ultraviolet light generated by a nitrogen laser. Using this laser microsurgical technique, we have measured channel activity across plasma membranes of V. faba guard cells in both cell-attached and isolated patch configurations. Measurements made in the inside-out patch configuration revealed two distinct K(+)-selective channels. Major advantages of the laser microsurgical technique include the avoidance of enzymatic protoplast isolation, the ability to study cell types that have been difficult to isolate as protoplasts or for which enzymatic isolation protocols result in protoplasts not amenable to patch-clamp studies, the maintenance of positional information in single-channel measurements, reduced disruption of cell-wall-mediated signaling pathways, and the ability to investigate intercellular signaling through studies of cells remaining situated within tissue.
Takahashi, Michiro; Saiura, Akio; Takahashi, Yu
2017-11-01
Patients with tumors invading major veins may require combined resection and reconstruction. However, venous reconstruction often demands complex hepatobiliary and vascular surgical procedures. In this study, we report a simple patch repair technique for venous reconstruction using the repermeabilized umbilical vein of the round ligament. We reviewed the outcomes of eleven patients who underwent venous wedge resection and patch repair using the repermeabilized umbilical vein of the round ligament at our institution. Procurement of the round ligament and method of making a patch is simple. The duration of anastomosis was approximately 15 min. Eight patients (73%) underwent hepatic resection followed by hepatic vein reconstruction; two (18%) pancreaticoduodenectomy followed by inferior vena cava (IVC) reconstruction; one (9%) hepatic resection followed by IVC reconstruction. Although one reconstructed vein became narrowed, the other ten veins were patent after surgery. Patch repair using the repermeabilized umbilical vein of the round ligament is a simple and useful technique.
Evaluation of urgent esophagectomy in esophageal perforation
de AQUINO, José Luis Braga; de CAMARGO, José Gonzaga Teixeira; CECCHINO, Gustavo Nardini; PEREIRA, Douglas Alexandre Rizzanti; BENTO, Caroline Agnelli; LEANDRO-MERHI, Vânia Aparecida
2014-01-01
Background Esophageal trauma is considered one of the most severe lesions of the digestive tract. There is still much controversy in choosing the best treatment for cases of esophageal perforation since that decision involves many variables. The readiness of medical care, the patient's clinical status, the local conditions of the perforated segment, and the severity of the associated injuries must be considered for the most adequate therapeutic choice. Aim To demonstrate and to analyze the results of urgent esophagectomy in a series of patients with esophageal perforation. Methods A retrospective study of 31 patients with confirmed esophageal perforation. Most injuries were due to endoscopic dilatation of benign esophageal disorders, which had evolved with stenosis. The diagnosis of perforation was based on clinical parameters, laboratory tests, and endoscopic images. The main surgical technique used was transmediastinal esophagectomy followed by reconstruction of the digestive tract in a second surgical procedure. Patients were evaluated for the development of systemic and local complications, especially for the dehiscence or stricture of the anastomosis of the cervical esophagus with either the stomach or the transposed colon. Results Early postoperative evaluation showed a survival rate of 77.1% in relation to the proposed surgery, and 45% of these patients presented no further complications. The other patients had one or more complications, being pulmonary infection and anastomotic fistula the most frequent. The seven patients (22.9%) who underwent esophageal resection 48 hours after the diagnosis died of sepsis. At medium and long-term assessments, most patients reported a good quality of life and full satisfaction regarding the surgery outcomes. Conclusions Despite the morbidity, emergency esophagectomy has its validity, especially in well indicated cases of esophageal perforation subsequent to endoscopic dilation for benign strictures. PMID:25626932
NASA Astrophysics Data System (ADS)
Koziel, Slawomir; Bekasiewicz, Adrian
2018-02-01
In this article, a simple yet efficient and reliable technique for fully automated multi-objective design optimization of antenna structures using sequential domain patching (SDP) is discussed. The optimization procedure according to SDP is a two-step process: (i) obtaining the initial set of Pareto-optimal designs representing the best possible trade-offs between considered conflicting objectives, and (ii) Pareto set refinement for yielding the optimal designs at the high-fidelity electromagnetic (EM) simulation model level. For the sake of computational efficiency, the first step is realized at the level of a low-fidelity (coarse-discretization) EM model by sequential construction and relocation of small design space segments (patches) in order to create a path connecting the extreme Pareto front designs obtained beforehand. The second stage involves response correction techniques and local response surface approximation models constructed by reusing EM simulation data acquired in the first step. A major contribution of this work is an automated procedure for determining the patch dimensions. It allows for appropriate selection of the number of patches for each geometry variable so as to ensure reliability of the optimization process while maintaining its low cost. The importance of this procedure is demonstrated by comparing it with uniform patch dimensions.
Method for identifying known materials within a mixture of unknowns
Wagner, John S.
2000-01-01
One or both of two methods and systems are used to determine concentration of a known material in an unknown mixture on the basis of the measured interaction of electromagnetic waves upon the mixture. One technique is to utilize a multivariate analysis patch technique to develop a library of optimized patches of spectral signatures of known materials containing only those pixels most descriptive of the known materials by an evolutionary algorithm. Identity and concentration of the known materials within the unknown mixture is then determined by minimizing the residuals between the measurements from the library of optimized patches and the measurements from the same pixels from the unknown mixture. Another technique is to train a neural network by the genetic algorithm to determine the identity and concentration of known materials in the unknown mixture. The two techniques may be combined into an expert system providing cross checks for accuracy.
System for identifying known materials within a mixture of unknowns
Wagner, John S.
1999-01-01
One or both of two methods and systems are used to determine concentration of a known material in an unknown mixture on the basis of the measured interaction of electromagnetic waves upon the mixture. One technique is to utilize a multivariate analysis patch technique to develop a library of optimized patches of spectral signatures of known materials containing only those pixels most descriptive of the known materials by an evolutionary algorithm. Identity and concentration of the known materials within the unknown mixture is then determined by minimizing the residuals between the measurements from the library of optimized patches and the measurements from the same pixels from the unknown mixture. Another technique is to train a neural network by the genetic algorithm to determine the identity and concentration of known materials in the unknown mixture. The two techniques may be combined into an expert system providing cross checks for accuracy.
Jonas, E A; Knox, R J; Kaczmarek, L K
1997-07-01
A method is outlined for obtaining giga-ohm seals on intracellular membranes in intact cells. The technique employs a variant of the patch-clamp technique: a concentric electrode arrangement protects an inner patch pipette during penetration of the plasma membrane, after which a seal can be formed on an internal organelle membrane. Using this technique, successful recordings can be obtained with the same frequency as with conventional patch clamping. To localize the position of the pipette within cells, lipophilic fluorescent dyes are included in the pipette solution. These dyes stain the membrane of internal organelles during seal formation and can then be visualized by video-enhanced or confocal imaging. The method can detect channels activated by inositol trisphosphate, as well as other types of intracellular membrane ion channel activity, and should facilitate studies of internal membranes in intact neurons and other cell types.
System for identifying known materials within a mixture of unknowns
Wagner, J.S.
1999-07-20
One or both of two methods and systems are used to determine concentration of a known material in an unknown mixture on the basis of the measured interaction of electromagnetic waves upon the mixture. One technique is to utilize a multivariate analysis patch technique to develop a library of optimized patches of spectral signatures of known materials containing only those pixels most descriptive of the known materials by an evolutionary algorithm. Identity and concentration of the known materials within the unknown mixture is then determined by minimizing the residuals between the measurements from the library of optimized patches and the measurements from the same pixels from the unknown mixture. Another technique is to train a neural network by the genetic algorithm to determine the identity and concentration of known materials in the unknown mixture. The two techniques may be combined into an expert system providing cross checks for accuracy. 37 figs.
Protein kinase C enhances the swelling-induced chloride current in human atrial myocytes.
Li, Ye-Tao; Du, Xin-Ling
2016-06-01
Swelling-activated chloride currents (ICl.swell) are thought to play a role in several physiologic and pathophysiologic processes and thus represent a target for therapeutic approaches. However, the mechanism of ICl.swell regulation remains unclear. In this study, we used the whole-cell patch-clamp technique to examine the role of protein kinase C (PKC) in the regulation of ICl.swell in human atrial myocytes. Atrial myocytes were isolated from the right atrial appendages of patients undergoing coronary artery bypass and enzymatically dissociated. ICl.swell was evoked in hypotonic solution and recorded using the whole-cell patch-clamp technique. The PKC agonist phorbol dibutyrate (PDBu) enhanced ICl.swell in a concentration-dependent manner, which was reversed in isotonic solution and by a chloride current inhibitor, 9-anthracenecarboxylicacid. Furthermore, the PKC inhibitor bis-indolylmaleimide attenuated the effect and 4α-PDBu, an inactive PDBu analog, had no effect on ICl.swell. These results, obtained using the whole-cell patch-clamp technique, demonstrate the ability of PKC to activate ICl,swell in human atrial myocytes. This observation was consistent with a previous study using a single-channel patch-clamp technique, but differed from some findings in other species.
Extracorporeal total artificial heart as bailout surgery.
Perrodin, Stéphanie F; Muller, Olivier; Gronchi, Fabrizio; Liaudet, Lucas; Hullin, Roger; Kirsch, Matthias
2017-03-01
We report the use of a total extracorporeal heart for uncontrolled bleeding following a proximal left anterior descending artery perforation, using two centrifugal ventricular assist devices after heart explantation. The literature describing similar techniques and patient outcomes for this "bailout" technique are reviewed. © 2017 Wiley Periodicals, Inc.
Veenstra, Richard D
2016-01-01
The development of the patch clamp technique has enabled investigators to directly measure gap junction conductance between isolated pairs of small cells with resolution to the single channel level. The dual patch clamp recording technique requires specialized equipment and the acquired skill to reliably establish gigaohm seals and the whole cell recording configuration with high efficiency. This chapter describes the equipment needed and methods required to achieve accurate measurement of macroscopic and single gap junction channel conductances. Inherent limitations with the dual whole cell recording technique and methods to correct for series access resistance errors are defined as well as basic procedures to determine the essential electrical parameters necessary to evaluate the accuracy of gap junction conductance measurements using this approach.
Micromachined patch-clamp apparatus
Okandan, Murat
2012-12-04
A micromachined patch-clamp apparatus is disclosed for holding one or more cells and providing electrical, chemical, or mechanical stimulation to the cells during analysis with the patch-clamp technique for studying ion channels in cell membranes. The apparatus formed on a silicon substrate utilizes a lower chamber formed from silicon nitride using surface micromachining and an upper chamber formed from a molded polymer material. An opening in a common wall between the chambers is used to trap and hold a cell for analysis using the patch-clamp technique with sensing electrodes on each side of the cell. Some embodiments of the present invention utilize one or more electrostatic actuators formed on the substrate to provide mechanical stimulation to the cell being analyzed, or to provide information about mechanical movement of the cell in response to electrical or chemical stimulation.
[Mannheim peritonitis index as a surgical criterion for perforative duodenal ulcer].
Krylov, N N; Babkin, O V; Babkin, D O
to define the correlation between Mannheim peritonitis index scores and outcomes of different radical and palliative interventions for perforative duodenal ulcer. Treatment of 386 patients with perforative duodenal ulcer is presented. Different surgical techniques were analyzed including stomach resection, various methods of vagotomy with/without drainage, ulcer suturing and ulcerative edges excision with suturing in patients with Mannheim index scores <21, 21-29 and over 29. Clavien-Dindo classification was used to analyze postoperative complications. In 64.3% of cases mortality was caused by peritonitis and peritonitis-associated complications. Surgical features resulted unfavorable outcome only in 35.7% of cases. Severe complications requiring re-operation were predominantly observed after stomach resection. Mannheim peritonitis index is sensitive method allowing prognosis the outcomes in patients with perforative duodenal ulcer. Radical interventions are advisable in Mannheim index scores <21, in other cases palliative surgery for example suturing or edges excision with suturing is preferred. If radical surgery is performed with strict indications (Mannheim index scores <21) volume and type of surgery do not significantly influence on mortality rate.
Billups, B; Szatkowski, M; Rossi, D; Attwell, D
1998-01-01
We have described how a combination of electrical, ion-sensing, and glutamate-sensing techniques has advanced our understanding of glutamate uptake into isolated salamander retinal glial cells. The next steps in understanding glutamate transport will inevitably depend strongly on molecular biological methods, as described elsewhere in this book, but will also require more detailed study of transporters in their normal environment, perhaps by using patch-clamping or imaging techniques to study cells in situ.
Cusp repair in aortic valve reconstruction: does the technique affect stability?
Aicher, Diana; Langer, Frank; Adam, Oliver; Tscholl, Dietmar; Lausberg, Henning; Schäfers, Hans-Joachim
2007-12-01
Cusp prolapse may be an isolated cause of aortic regurgitation or may exist in conjunction with dilatation of the proximal aorta. Prolapse can be corrected by central plication, triangular resection, or pericardial patch implantation. We retrospectively analyzed our results with these techniques. From October 1995 to December 2006, 604 patients (aged 3-86 years) underwent aortic valve repair. Cusp prolapse was found in 427 patients (246 tricuspid, 181 bicuspid). Prolapse was corrected by central plication (n = 275) or triangular resection (n = 80). A pericardial patch was implanted for pre-existing cusp defects or after excision of calcium (n = 72). One cusp was repaired in 198 patients; the remaining patients underwent repair of 2 (n = 189) or 3 cusps (n = 40). In 102 patients more than one technique was used, and the patients were allocated to the group of the assumedly more complex repair (central plication < triangular resection < pericardial patch plasty). Cumulative follow-up was 1238 patient-years (mean 35 +/- 27 months). Hospital mortality was 2.6% (11/427). Actuarial freedom from aortic regurgitation of grade II or more at 5 years was 92% (central plication), 90% (triangular resection), and 90% (pericardial patch plasty). Thirteen patients were reoperated on, with prolapse as the most common reason for failure (n = 7); 6 underwent re-repair. Freedom from reoperation at 5 years was 95% (central plication), 94% (triangular resection), and 94% (pericardial patch plasty). Freedom from valve replacement at 5 years was 97% (central plication), 99% (triangular resection), and 98% (pericardial patch plasty). In aortic valve repair, cusp prolapse can be treated reliably by central plication. In the presence of more complex disease, triangular resection or pericardial patch plasty may be used without compromising midterm durability.
Surface sampling techniques for 3D object inspection
NASA Astrophysics Data System (ADS)
Shih, Chihhsiong S.; Gerhardt, Lester A.
1995-03-01
While the uniform sampling method is quite popular for pointwise measurement of manufactured parts, this paper proposes three novel sampling strategies which emphasize 3D non-uniform inspection capability. They are: (a) the adaptive sampling, (b) the local adjustment sampling, and (c) the finite element centroid sampling techniques. The adaptive sampling strategy is based on a recursive surface subdivision process. Two different approaches are described for this adaptive sampling strategy. One uses triangle patches while the other uses rectangle patches. Several real world objects were tested using these two algorithms. Preliminary results show that sample points are distributed more closely around edges, corners, and vertices as desired for many classes of objects. Adaptive sampling using triangle patches is shown to generally perform better than both uniform and adaptive sampling using rectangle patches. The local adjustment sampling strategy uses a set of predefined starting points and then finds the local optimum position of each nodal point. This method approximates the object by moving the points toward object edges and corners. In a hybrid approach, uniform points sets and non-uniform points sets, first preprocessed by the adaptive sampling algorithm on a real world object were then tested using the local adjustment sampling method. The results show that the initial point sets when preprocessed by adaptive sampling using triangle patches, are moved the least amount of distance by the subsequently applied local adjustment method, again showing the superiority of this method. The finite element sampling technique samples the centroids of the surface triangle meshes produced from the finite element method. The performance of this algorithm was compared to that of the adaptive sampling using triangular patches. The adaptive sampling with triangular patches was once again shown to be better on different classes of objects.
Yang, Xue-Fei
2014-01-01
Among the colorectal cancers, the incidence of colon cancer has obviously increased. As a result, the actual incidence of colon cancer has exceeded that of rectal cancer, which dramatically changed the long-existing epidemiological profile. The acute complications of colon cancer include bleeding, obstruction, and perforation, which were among the common acute abdominal surgical conditions. The rapid and accurate diagnosis of these acute complications was very important, and laparoscopic techniques can be applied in abdominal surgery for management of the complications. PMID:25035661
Modified Nuss repair for pectus carinatum.
Poullis, Michael
2010-09-01
A minimally-invasive modified Nuss technique is described for pectus carinatum which has reduced risk of cardiac perforation compared to a standard Nuss procedure, and avoids performing the Ravitch procedure.
NASA Astrophysics Data System (ADS)
Chandler, Damon M.; Field, David J.
2007-04-01
Natural scenes, like most all natural data sets, show considerable redundancy. Although many forms of redundancy have been investigated (e.g., pixel distributions, power spectra, contour relationships, etc.), estimates of the true entropy of natural scenes have been largely considered intractable. We describe a technique for estimating the entropy and relative dimensionality of image patches based on a function we call the proximity distribution (a nearest-neighbor technique). The advantage of this function over simple statistics such as the power spectrum is that the proximity distribution is dependent on all forms of redundancy. We demonstrate that this function can be used to estimate the entropy (redundancy) of 3×3 patches of known entropy as well as 8×8 patches of Gaussian white noise, natural scenes, and noise with the same power spectrum as natural scenes. The techniques are based on assumptions regarding the intrinsic dimensionality of the data, and although the estimates depend on an extrapolation model for images larger than 3×3, we argue that this approach provides the best current estimates of the entropy and compressibility of natural-scene patches and that it provides insights into the efficiency of any coding strategy that aims to reduce redundancy. We show that the sample of 8×8 patches of natural scenes used in this study has less than half the entropy of 8×8 white noise and less than 60% of the entropy of noise with the same power spectrum. In addition, given a finite number of samples (<220) drawn randomly from the space of 8×8 patches, the subspace of 8×8 natural-scene patches shows a dimensionality that depends on the sampling density and that for low densities is significantly lower dimensional than the space of 8×8 patches of white noise and noise with the same power spectrum.
Scattering from arbitrarily shaped microstrip patch antennas
NASA Technical Reports Server (NTRS)
Shively, David G.; Deshpande, Manohar D.; Cockrell, Capers R.
1992-01-01
The scattering properties of arbitrarily shaped microstrip patch antennas are examined. The electric field integral equation for a current element on a grounded dielectric slab is developed for a rectangular geometry based on Galerkin's technique with subdomain rooftop basis functions. A shape function is introduced that allows a rectangular grid approximation to the arbitrarily shaped patch. The incident field on the patch is expressed as a function of incidence angle theta(i), phi(i). The resulting system of equations is then solved for the unknown current modes on the patch, and the electromagnetic scattering is calculated for a given angle. Comparisons are made with other calculated results as well as with measurements.
Veerman, Christiaan C.; Zegers, Jan G.; Mengarelli, Isabella; Bezzina, Connie R.
2017-01-01
Human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) hold great promise for studying inherited cardiac arrhythmias and developing drug therapies to treat such arrhythmias. Unfortunately, until now, action potential (AP) measurements in hiPSC-CMs have been hampered by the virtual absence of the inward rectifier potassium current (IK1) in hiPSC-CMs, resulting in spontaneous activity and altered function of various depolarising and repolarising membrane currents. We assessed whether AP measurements in “ventricular-like” and “atrial-like” hiPSC-CMs could be improved through a simple, highly reproducible dynamic clamp approach to provide these cells with a substantial IK1 (computed in real time according to the actual membrane potential and injected through the patch-clamp pipette). APs were measured at 1 Hz using perforated patch-clamp methodology, both in control cells and in cells treated with all-trans retinoic acid (RA) during the differentiation process to increase the number of cells with atrial-like APs. RA-treated hiPSC-CMs displayed shorter APs than control hiPSC-CMs and this phenotype became more prominent upon addition of synthetic IK1 through dynamic clamp. Furthermore, the variability of several AP parameters decreased upon IK1 injection. Computer simulations with models of ventricular-like and atrial-like hiPSC-CMs demonstrated the importance of selecting an appropriate synthetic IK1. In conclusion, the dynamic clamp-based approach of IK1 injection has broad applicability for detailed AP measurements in hiPSC-CMs. PMID:28867785
cAMP-dependent kinase does not modulate the Slack sodium-activated potassium channel.
Nuwer, Megan O; Picchione, Kelly E; Bhattacharjee, Arin
2009-09-01
The Slack gene encodes a Na(+)-activated K(+) channel and is expressed in many different types of neurons. Like the prokaryotic Ca(2+)-gated K(+) channel MthK, Slack contains two 'regulator of K(+) conductance' (RCK) domains within its carboxy terminal, domains likely involved in Na(+) binding and channel gating. It also contains multiple consensus protein kinase C (PKC) and protein kinase A (PKA) phosphorylation sites and although regulated by protein kinase C (PKC) phosphorylation, modulation by PKA has not been determined. To test if PKA directly regulates Slack, nystatin-perforated patch whole-cell currents were recorded from a human embryonic kidney (HEK-293) cell line stably expressing Slack. Bath application of forskolin, an adenylate cyclase activator, caused a rapid and complete inhibition of Slack currents however, the inactive homolog of forskolin, 1,9-dideoxyforskolin caused a similar effect. In contrast, bath application of 8-bromo-cAMP did not affect the amplitude nor the activation kinetics of Slack currents. In excised inside-out patch recordings, direct application of the PKA catalytic subunit to patches did not affect the open probability of Slack channels nor was open probability affected by direct application of protein phosphatase 2B. Preincubation of cells with the protein kinase A inhibitor KT5720 also did not change current density. Finally, mutating the consensus phosphorylation site located between RCK domain 1 and domain 2 from serine to glutamate did not affect current activation kinetics. We conclude that unlike PKC, phosphorylation by PKA does not acutely modulate the function and gating activation kinetics of Slack channels.
The palisade cartilage tympanoplasty technique: a systematic review and meta-analysis.
Jeffery, Caroline C; Shillington, Cameron; Andrews, Colin; Ho, Allan
2017-06-17
Tympanoplasty is a common procedure performed by Otolaryngologists. Many types of autologous grafts have been used with variations of techniques with varying results. This is the first systematic review of the literature and meta-analysis with the aim to evaluate the effectiveness of one of the techniques which is gaining popularity, the palisade cartilage tympanoplasty. PubMed, EMBASE, and Cochrane databases were searched for "palisade", "cartilage", "tympanoplasty", "perforation" and their synonyms. In total, 199 articles reporting results of palisade cartilage tympanoplasty were identified. Five articles satisfied the following inclusion criteria: adult patients, minimum 6 months follow-up, hearing and surgical outcomes reported. Studies with patients undergoing combined mastoidectomy, ossicular chain reconstruction, and/or other middle ear surgery were excluded. Perforation closure, rate of complications, and post-operative pure-tone average change were extracted for pooled analysis. Study failure and complication proportions that were used to generate odds ratios were pooled. Fixed effects and random effects weightings were generated. The resulting pooled odds ratios are reported. Palisade cartilage tympanoplasty has an overall take rate of 96% at beyond 6 months and has similar odds of complications compared to temporalis fascia (OR 0.89, 95% CI 0.62, 1.30). The air-bone gap closure is statistically similar to reported results from temporalis fascia tympanoplasty. Cartilage palisade tympanoplasty offers excellent graft take rates and good postoperative hearing outcomes for perforations of various sizes and for both primary and revision cases. This technique has predictable, long-term results with low complication rates, similar to temporalis fascia tympanoplasty.
Kuo, Che-Ying; Wilson, Emmanuel; Fuson, Andrew; Gandhi, Nidhi; Monfaredi, Reza; Jenkins, Audrey; Romero, Maria; Santoro, Marco; Fisher, John P; Cleary, Kevin; Reilly, Brian
2018-03-01
The goal of this work is to develop an innovative method that combines bioprinting and endoscopic imaging to repair tympanic membrane perforations (TMPs). TMPs are a serious health issue because they can lead to both conductive hearing loss and repeated otitis media. TMPs occur in 3-5% of cases after ear tube placement, as well as in cases of acute otitis media (the second most common infection in pediatrics), chronic otitis media with or without cholesteatoma, or as a result of barotrauma to the ear. About 55,000 tympanoplasties, the surgery performed to reconstruct TMPs, are performed every year, and the commonly used cartilage grafting technique has a success rate between 43% and 100%. This wide variability in successful tympanoplasty indicates that the current approach relies heavily on the skill of the surgeon to carve the shield graft into the shape of the TMP, which can be extremely difficult because of the perforation's irregular shape. To this end, we hypothesized that patient specific acellular grafts can be bioprinted to repair TMPs. In vitro data demonstrated that our approach resulted in excellent wound healing responses (e.g., cell invasion and proliferations) using our bioprinted gelatin methacrylate constructs. Based on these results, we then bioprinted customized acellular grafts to treat TMP based on endoscopic imaging of the perforation and demonstrated improved TMP healing in a chinchilla study. These ear graft techniques could transform clinical practice by eliminating the need for hand-carved grafts. To our knowledge, this is the first proof of concept of using bioprinting and endoscopic imaging to fabricate customized grafts to treat tissue perforations. This technology could be transferred to other medical pathologies and be used to rapidly scan internal organs such as intestines for microperforations, brain covering (Dura mater) for determination of sites of potential cerebrospinal fluid leaks, and vascular systems to determine arterial wall damage before aneurysm rupture in strokes.
Application of level set method to optimal vibration control of plate structures
NASA Astrophysics Data System (ADS)
Ansari, M.; Khajepour, A.; Esmailzadeh, E.
2013-02-01
Vibration control plays a crucial role in many structures, especially in the lightweight ones. One of the most commonly practiced method to suppress the undesirable vibration of structures is to attach patches of the constrained layer damping (CLD) onto the surface of the structure. In order to consider the weight efficiency of a structure, the best shapes and locations of the CLD patches should be determined to achieve the optimum vibration suppression with minimum usage of the CLD patches. This paper proposes a novel topology optimization technique that can determine the best shape and location of the applied CLD patches, simultaneously. Passive vibration control is formulated in the context of the level set method, which is a numerical technique to track shapes and locations concurrently. The optimal damping set could be found in a structure, in its fundamental vibration mode, such that the maximum modal loss factor of the system is achieved. Two different plate structures will be considered and the damping patches will be optimally located on them. At the same time, the best shapes of the damping patches will be determined too. In one example, the numerical results will be compared with those obtained from the experimental tests to validate the accuracy of the proposed method. This comparison reveals the effectiveness of the level set approach in finding the optimum shape and location of the CLD patches.
Bilateral Mycobacterium chelonae Keratitis after Phacoemulsification Cataract Surgery.
Martinez, Jaime D; Amescua, Guillermo; Lozano-Cárdenas, Jesus; Suh, Leejee H
2017-01-01
The purpose of this manuscript is to report the case of an 81-year-old patient who presented with bilateral keratitis after phacoemulsification surgery. Cultures came back positive for Mycobacterium chelonae . Despite aggressive topical and systemic antimicrobial treatment, the patient developed a corneal perforation in both eyes, treated with corneal glue in the right eye and corneoscleral patch in the left eye. After two years of follow-up, patient was free of infection in the right eye with visual acuity of 20/200 and the left eye progressed to phthisis bulbi. We present an unusual case of bilateral Mycobacterium chelonae keratitis associated with phacoemulsification cataract surgery. This case represents the importance of making clinicians aware of this devastating infection and highlights the need for better management to improve outcomes.
Management of post-gastrectomy anastomosis site obstruction with a self-expandable metallic stent.
Cha, Ra Ri; Lee, Sang Soo; Kim, Hyunjin; Kim, Hong Jun; Kim, Tae-Hyo; Jung, Woon Tae; Lee, Ok Jae; Bae, Kyung Soo; Jeong, Sang-Ho; Ha, Chang Yoon
2015-04-28
Post-gastrectomy anastomosis site obstruction is a relatively rare complication after a subtotal gastrectomy. We present a case of a 75-year-old man who underwent a truncal vagotomy, omental patch, gastrojejunostomy, and Braun anastomosis for duodenal ulcer perforation and a gastric outlet obstruction. Following the 10(th) postoperative day, the patient complained of abdominal discomfort and vomiting. We diagnosed post-gastrectomy anastomosis site obstruction by an upper gastrointestinal series and an upper endoscopic examination. We inserted a self-expandable metallic stent (SEMS) at the anastomosis site. The stent was fully expanded after deployment. On the day following the stent insertion, the patient began to eat, and his abdominal discomfort was resolved. This paper describes the successful management of post-gastrectomy anastomosis site obstruction with temporary placement of a SEMS.
Visualization of AMR data with multi-level dual-mesh interpolation.
Moran, Patrick J; Ellsworth, David
2011-12-01
We present a new technique for providing interpolation within cell-centered Adaptive Mesh Refinement (AMR) data that achieves C(0) continuity throughout the 3D domain. Our technique improves on earlier work in that it does not require that adjacent patches differ by at most one refinement level. Our approach takes the dual of each mesh patch and generates "stitching cells" on the fly to fill the gaps between dual meshes. We demonstrate applications of our technique with data from Enzo, an AMR cosmological structure formation simulation code. We show ray-cast visualizations that include contributions from particle data (dark matter and stars, also output by Enzo) and gridded hydrodynamic data. We also show results from isosurface studies, including surfaces in regions where adjacent patches differ by more than one refinement level. © 2011 IEEE
Homogenization techniques for population dynamics in strongly heterogeneous landscapes.
Yurk, Brian P; Cobbold, Christina A
2018-12-01
An important problem in spatial ecology is to understand how population-scale patterns emerge from individual-level birth, death, and movement processes. These processes, which depend on local landscape characteristics, vary spatially and may exhibit sharp transitions through behavioural responses to habitat edges, leading to discontinuous population densities. Such systems can be modelled using reaction-diffusion equations with interface conditions that capture local behaviour at patch boundaries. In this work we develop a novel homogenization technique to approximate the large-scale dynamics of the system. We illustrate our approach, which also generalizes to multiple species, with an example of logistic growth within a periodic environment. We find that population persistence and the large-scale population carrying capacity is influenced by patch residence times that depend on patch preference, as well as movement rates in adjacent patches. The forms of the homogenized coefficients yield key theoretical insights into how large-scale dynamics arise from the small-scale features.
Urbach, V; Van Kerkhove, E; Maguire, D; Harvey, B J
1996-01-01
Isolated frog skin epithelium, mounted in an Ussing chamber and bathed in standard NaCl Ringer solution, recycles K+ across the basolateral membrane of principal cells through an inward-rectifier K+ channel (Kir) operating in parallel with a Na+-K+-ATPase pump. Here we report on the metabolic control of the Kir channel using patch clamping, short-circuit current measurement and enzymatic determination of cellular (ATP (ATPi). 2. The constitutively active Kir channel in the basolateral membrane has the characteristics of an ATP-regulated K+ channel and is now classed as a KATP channel. In excised inside-out patches the open probability (Po) of KATP channels was reduced by ATPi with half-maximum inhibition at an ATPi concentration of 50 microM. 3. ATPi measured (under normal Na+ transport conditions) with luciferin-luciferase was 1.50 +/- 0.23 mM (mean +/- S.E.M.; range, 0.4-3.3 mM n = 11). Thus the KATP channel would be expected to be inactive in intact cells if ATPi was the sole regulator of channel activity. KATP channels which were inactivated by 1 mM ATPi in excised patches could be reactivated by addition of 100 microM ADP on the cytosolic side. When added alone, ADP blocks this channel with half-maximal inhibition at [ADPi] > 5 mM. 4. Sulphonylureas inhibit single KATP channels in cell-attached patches as well as the total basolateral K+ current measured in frog skin epithelia perforated with nystatin on the apical side. 5. Na+-K+-ATPase activity is a major determinant of cytosolic ATP. Blocking the pump activity with ouabain produced a time-dependent increase in ATPi and reduced the open probability of KATP channels in cell-attached membranes. 6. We conclude that the ratio of ATP/ADP is an important metabolic coupling factor between the rate of Na+-K+ pumping and K+ recycling. Images Figure 9 PMID:9011625
NASA Astrophysics Data System (ADS)
Bi, ChuanXing; Jing, WenQian; Zhang, YongBin; Xu, Liang
2015-02-01
The conventional nearfield acoustic holography (NAH) is usually based on the assumption of free-field conditions, and it also requires that the measurement aperture should be larger than the actual source. This paper is to focus on the problem that neither of the above-mentioned requirements can be met, and to examine the feasibility of reconstructing the sound field radiated by partial source, based on double-layer pressure measurements made in a non-free field by using patch NAH combined with sound field separation technique. And also, the sensitivity of the reconstructed result to the measurement error is analyzed in detail. Two experiments involving two speakers in an exterior space and one speaker inside a car cabin are presented. The experimental results demonstrate that the patch NAH based on single-layer pressure measurement cannot obtain a satisfied result due to the influences of disturbing sources and reflections, while the patch NAH based on double-layer pressure measurements can successfully remove these influences and reconstruct the patch sound field effectively.
Case Report Reconstruction of Exposed Ilium With Reverse Turnover Latissimus Dorsi Muscle Flap
Hayashida, Kenji; Endo, Yoshie; Kamebuchi, Katsuhiko
2011-01-01
Objective: It is difficult to cover a large skin and soft tissue defect with exposure of the ilium. We therefore performed a new reconstruction technique, using a reverse latissimus dorsi muscle flap fed by perforating branches of only the 10th intercostal artery. Methods: A 45-year-old man had a large traumatic defect located on the hip with exposure of the iliac crest. After confirming and preserving perforating branches of the 10th intercostal artery, the latissimus dorsi muscle flap was turned over just proximal to the perforating branch, and a split-thickness skin graft was performed over the flap. Results: The skin graft took place well and there were no circulation problems. Conclusions: This flap covered a larger area on the hip than the musculocutaneous flap. Furthermore, this is easier to perform and is less invasive than a vascularized free flap. Skin and soft tissue defects that expose bones of the lumbar or hip region can be reconstructed with a local flap; however, the deficit is small for this coverage and usually there is little skin and soft tissue to cover the wound defect in the surrounding area. Thus, it is often difficult to deal with large defects. We performed a reconstruction, using a reverse latissimus dorsi flap fed by perforating branches of the 10th intercostal artery for a large skin and soft tissue defect of the hip with exposure of the iliac crest, resulting in a good outcome. This technique is thought to be useful for reconstruction when the ilium is exposed, and we report the case and surgical procedure. PMID:21559059
Computer-enhanced robotic telesurgery minimizes esophageal perforation during Heller myotomy.
Melvin, W Scott; Dundon, John M; Talamini, Mark; Horgan, Santiago
2005-10-01
Laparoscopic Heller myotomy has emerged as the treatment of choice for achalasia. However, intraoperative esophageal perforation remains a significant complication. Computer-enhanced operative techniques have the potential to improve outcomes for certain operative procedures. Robotic, computer-enhanced laparoscopic telemanipulators using 3-dimensional magnified imaging and motion scaling are designed uniquely to facilitate certain operations requiring fine-tissue manipulation. We hypothesized that computer-enhanced robotic Heller myotomy would reduce intraoperative complications compared with laparoscopic techniques. All patients undergoing an operation for achalasia at 3 institutions with a robotic surgery system (DaVinci; Intuitive Surgical Corporation, Sunnyvale, Calif) were followed-up prospectively. Demographics, perioperative course, complications, and hospital stay were recorded. Follow-up evaluation was obtained via a standardized symptom survey, office visits, and medical records. Data were compared with preoperative symptoms using a Mann-Whitney U test, and operating times were compared using the ANOVA test. Between August 2000 and August 2004 there were 104 patients who underwent a robotic Heller myotomy with partial fundoplicaton. There were 53 women and 51 men. All patients were symptomatic. The operative time was 140.55 minutes overall, but improved from 162.63 minutes to 113.50 minutes from 2000-2002 to 2003-2004 (P = .0001). There were no esophageal perforations. There were 8 minor complications and 1 patient required conversion to an open operation. Sixty-six (62.3%) patients were discharged on the first postoperative day and the average hospital stay was 1.5 days. A symptom survey was completed in 79 of 104 patients (76%) at follow-up evaluation. Symptoms improved in all patients with an average follow-up symptom score of 0.48 compared with 5.0 before the operation (P = .0001). Forty-three of the 79 patients from whom follow-up data were collected had a minimum follow-up period of 1 year. The follow-up period averaged 16 months. No patients required reoperation. Computer-enhanced robotic laparoscopic techniques provide a clear advantage over standard laparoscopy for the operative treatment of achalasia. We have shown in this large series that Heller myotomy can be completed using this technology without esophageal perforation. The application of computer-enhanced operative techniques appears to provide superior outcomes in selected procedures.
Kim, Yoon Jae; Kim, Yoon Young
2010-10-01
This paper presents a numerical method for the optimization of the sequencing of solid panels, perforated panels and air gaps and their respective thickness for maximizing sound transmission loss and/or absorption. For the optimization, a method based on the topology optimization formulation is proposed. It is difficult to employ only the commonly-used material interpolation technique because the involved layers exhibit fundamentally different acoustic behavior. Thus, an optimization method formulation using a so-called unified transfer matrix is newly proposed. The key idea is to form elements of the transfer matrix such that interpolated elements by the layer design variables can be those of air, perforated and solid panel layers. The problem related to the interpolation is addressed and bench mark-type problems such as sound transmission or absorption maximization problems are solved to check the efficiency of the developed method.
HTS techniques for patch clamp-based ion channel screening - advances and economy.
Farre, Cecilia; Fertig, Niels
2012-06-01
Ten years ago, the first publication appeared showing patch clamp recordings performed on a planar glass chip instead of using a conventional patch clamp pipette. "Going planar" proved to revolutionize ion channel drug screening as we know it, by allowing high quality measurements of ion channels and their effectors at a higher throughput and at the same time de-skilling the highly laborious technique. Over the years, platforms evolved in response to user requirements regarding experimental features, data handling plus storage, and suitable target diversity. This article gives a snapshot image of patch clamp-based ion channel screening with focus on platforms developed to meet requirements of high-throughput screening environments. The commercially available platforms are described, along with their benefits and drawbacks in ion channel drug screening. Automated patch clamp (APC) platforms allow faster investigation of a larger number of ion channel active compounds or cell clones than previously possible. Since patch clamp is the only method allowing direct, real-time measurements of ion channel activity, APC holds the promise of picking up high quality leads, where they otherwise would have been overseen using indirect methods. In addition, drug candidate safety profiling can be performed earlier in the drug discovery process, avoiding late-phase compound withdrawal due to safety liability issues, which is highly costly and inefficient.
Polonchuk, Liudmila
2014-01-01
Patch-clamping is a powerful technique for investigating the ion channel function and regulation. However, its low throughput hampered profiling of large compound series in early drug development. Fortunately, automation has revolutionized the area of experimental electrophysiology over the past decade. Whereas the first automated patch-clamp instruments using the planar patch-clamp technology demonstrated rather a moderate throughput, few second-generation automated platforms recently launched by various companies have significantly increased ability to form a high number of high-resistance seals. Among them is SyncroPatch(®) 96 (Nanion Technologies GmbH, Munich, Germany), a fully automated giga-seal patch-clamp system with the highest throughput on the market. By recording from up to 96 cells simultaneously, the SyncroPatch(®) 96 allows to substantially increase throughput without compromising data quality. This chapter describes features of the innovative automated electrophysiology system and protocols used for a successful transfer of the established hERG assay to this high-throughput automated platform.
Chloride equilibrium potential in salamander cones
Thoreson, Wallace B; Bryson, Eric J
2004-01-01
Background GABAergic inhibition and effects of intracellular chloride ions on calcium channel activity have been proposed to regulate neurotransmission from photoreceptors. To assess the impact of these and other chloride-dependent mechanisms on release from cones, the chloride equilibrium potential (ECl) was determined in red-sensitive, large single cones from the tiger salamander retinal slice. Results Whole cell recordings were done using gramicidin perforated patch techniques to maintain endogenous Cl- levels. Membrane potentials were corrected for liquid junction potentials. Cone resting potentials were found to average -46 mV. To measure ECl, we applied long depolarizing steps to activate the calcium-activated chloride current (ICl(Ca)) and then determined the reversal potential for the current component that was inhibited by the Cl- channel blocker, niflumic acid. With this method, ECl was found to average -46 mV. In a complementary approach, we used a Cl-sensitive dye, MEQ, to measure the Cl- flux produced by depolarization with elevated concentrations of K+. The membrane potentials produced by the various high K+ solutions were measured in separate current clamp experiments. Consistent with electrophysiological experiments, MEQ fluorescence measurements indicated that ECl was below -36 mV. Conclusions The results of this study indicate that ECl is close to the dark resting potential. This will minimize the impact of chloride-dependent presynaptic mechanisms in cone terminals involving GABAa receptors, glutamate transporters and ICl(Ca). PMID:15579212
Louges, M A; Bellaiche, J; Correia, N; Chiriac, S; François, C
2016-06-01
The presence of midline sub-umbilical and/or suprapubic scar can sometimes hinder breast reconstruction using deep inferior epigastric perforator (DIEP) procedure. We report the use of indocyanine green injection in a 60-year-old woman in the context of deep inferior epigastric perforator (DIEP) procedure for unilateral breast reconstruction (bilateral breast cancer) with abdominal scar (midline sub-umbilical scar and Pfannenstiel incision scar). This technique underlines the importance of neoangiogenesis mechanisms and helped simplify the surgical gesture initially planned (in order to ensure volume in spite of the scars as a DIEP procedure with double anastomoses was initially planned). This intraoperative vascular imaging technique is a minimally invasive, simple and quick procedure allowing the precise visualization of vascularized territories. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
An unusual case of perforation of the alimentary canal following Bigu: A Taoist fasting technique.
Wang, Jun; Jin, Jun; Xue, Xiaofeng; Hao, Yan; Li, Dongrong; Xu, Shan; Huang, Fang
2017-12-01
Bigu is a Taoist fasting technique interpreted as avoiding grains in the Encyclopedia of China. This technique has been used from ancient times to the present day in China and other parts of the world to achieve good health, weight loss, longevity, and even immortality. A variety of health problems have been identified in relation to the severe diet during Bigu. However, perforation of the alimentary canal has not been reported to be associated with Bigu. In the present study, we illustrated an unusual case of perforation of the alimentary canal in relation to Bigu. A 36-year-old woman was admitted to our hospital after falling into a coma. One month before admission, she had black stool accompanied by dizziness and fatigue, while the symptoms progressively worsened. The patient reported that she stopped the intake of meat for 5 years, and further practiced Bigu for 5 months, eating only fruits and vegetables, and avoiding grains and meat. Preformation of the alimentary canal. Gastric bypass operation, also known as Roux-en-Y anastomosis, was undertaken. Since the patient developed thrombus with edema on the right upper limb after surgical intervention, she was subsequently treated with anticoagulation therapy using low-molecular weight heparin. The patient's symptoms were remarkably improved and exhibited signs of recovery in follow-up examinations. The case has raises serious concerns about practicing Bigu. Furthermore, it is strongly advocated that a state of Bigu for a long period of time can even be dangerous.
In-vitro perforation of the round window membrane via direct 3-D printed microneedles.
Aksit, Aykut; Arteaga, Daniel N; Arriaga, Miguel; Wang, Xun; Watanabe, Hirobumi; Kasza, Karen E; Lalwani, Anil K; Kysar, Jeffrey W
2018-06-08
The cochlea, or inner ear, is a space fully enclosed within the temporal bone of the skull, except for two membrane-covered portals connecting it to the middle ear space. One of these portals is the round window, which is covered by the Round Window Membrane (RWM). A longstanding clinical goal is to reliably and precisely deliver therapeutics into the cochlea to treat a plethora of auditory and vestibular disorders. Standard of care for several difficult-to-treat diseases calls for injection of a therapeutic substance through the tympanic membrane into the middle ear space, after which a portion of the substance diffuses across the RWM into the cochlea. The efficacy of this technique is limited by an inconsistent rate of molecular transport across the RWM. A solution to this problem involves the introduction of one or more microscopic perforations through the RWM to enhance the rate and reliability of diffusive transport. This paper reports the use of direct 3D printing via Two-Photon Polymerization (2PP) lithography to fabricate ultra-sharp polymer microneedles specifically designed to perforate the RWM. The microneedle has tip radius of 500 nm and shank radius of 50 μ m, and perforates the guinea pig RWM with a mean force of 1.19 mN. The resulting perforations performed in vitro are lens-shaped with major axis equal to the microneedle shank diameter and minor axis about 25% of the major axis, with mean area 1670 μ m 2 . The major axis is aligned with the direction of the connective fibers within the RWM. The fibers were separated along their axes without ripping or tearing of the RWM suggesting the main failure mechanism to be fiber-to-fiber decohesion. The small perforation area along with fiber-to-fiber decohesion are promising indicators that the perforations would heal readily following in vivo experiments. These results establish a foundation for the use of Two-Photon Polymerization lithography as a means to fabricate microneedles to perforate the RWM and other similar membranes.
De Los Ríos, F. A.; Paluszny, M.
2015-01-01
We consider some methods to extract information about the rotator cuff based on magnetic resonance images; the study aims to define an alternative method of display that might facilitate the detection of partial tears in the supraspinatus tendon. Specifically, we are going to use families of ellipsoidal triangular patches to cover the humerus head near the affected area. These patches are going to be textured and displayed with the information of the magnetic resonance images using the trilinear interpolation technique. For the generation of points to texture each patch, we propose a new method that guarantees the uniform distribution of its points using a random statistical method. Its computational cost, defined as the average computing time to generate a fixed number of points, is significantly lower as compared with deterministic and other standard statistical techniques. PMID:25650281
Damage Assessment of Composite Structures Using Digital Image Correlation
NASA Astrophysics Data System (ADS)
Caminero, M. A.; Lopez-Pedrosa, M.; Pinna, C.; Soutis, C.
2014-02-01
The steady increase of Carbon-Fiber Reinforced Polymer (CFRP) Structures in modern aircraft will reach a new dimension with the entry into service of the Boeing 787 and Airbus 350. Replacement of damaged parts will not be a preferable solution due to the high level of integration and the large size of the components involved. Consequently the need to develop repair techniques and processes for composite components is readily apparent. Bonded patch repair technologies provide an alternative to mechanically fastened repairs with significantly higher performance, especially for relatively thin skins. Carefully designed adhesively bonded patches can lead to cost effective and highly efficient repairs in comparison with conventional riveted patch repairs that cut fibers and introduce highly strained regions. In this work, the assessment of the damage process taking place in notched (open-hole) specimens under uniaxial tensile loading was studied. Two-dimensional (2D) and three-dimensional (3D) Digital Image Correlation (DIC) techniques were employed to obtain full-field surface strain measurements in carbon-fiber/epoxy T700/M21 composite plates with different stacking sequences in the presence of an open circular hole. Penetrant enhanced X-ray radiographs were taken to identify damage location and extent after loading around the hole. DIC strain fields were compared to finite element predictions. In addition, DIC techniques were used to characterise damage and performance of adhesively bonded patch repairs in composite panels under tensile loading. This part of work relates to strength/stiffness restoration of damaged composite aircraft that becomes more important as composites are used more extensively in the construction of modern jet airliners. The behaviour of bonded patches under loading was monitored using DIC full-field strain measurements. Location and extent of damage identified by X-ray radiography correlates well with DIC strain results giving confidence to the technique for structural health monitoring of bonded patches.
Glove perforations and blood contact associated with manipulation of the fetal scalp electrode.
Rhoton-Vlasak, A; Duff, P
1993-02-01
To assess prospectively the frequency of glove injury associated with insertion of the fetal scalp electrode and subsequent examination of the cervix with the electrode in place. Over a 7-month period, sterile gloves were collected after use for insertion of the fetal scalp electrode or cervical examination with the electrode in place. Attendants indicated their level of training, time, date and purpose of glove use, and cervical examination. They also noted whether they were aware of a glove perforation or observed blood, amniotic fluid, or genital tract secretions on their hand. Glove patency was assessed by filling the glove with water to 1.5-2.0 times its normal volume and observing for leaks. One hundred unused gloves were tested for patency and served as controls. Five hundred one gloves were evaluated, of which 13 (2.6%, 95% confidence interval [Cl] 1-4%) had perforations. Seven of 277 gloves (2.5%) used only for examinations had perforations, compared with six of 244 (2.5%) used only for insertion of the electrode. Two percent (95% CI 0-5%) of the unused control gloves had perforations. These observed differences were not statistically significant. Nineteen attendants (3.8%, 95% CI 2.1-5.5%) noted blood or genital tract secretions on their hand after insertion of the electrode (N = 4) or subsequent cervical examination (N = 15). Only one point of contract resulted from a glove perforation; the other 18 were on the wrist and apparently resulted from leakage of fluid around the open cuff of the glove. The risk of glove perforation during insertion of the fetal scalp electrode or subsequent cervical examination is low if proper technique is observed. Blood or fluid contact is more likely to result from leakage of fluid around the open cuff of the glove during a vaginal examination.
Method of making an ion beam sputter-etched ventricular catheter for hydrocephalus shunt
NASA Technical Reports Server (NTRS)
Banks, B. A. (Inventor)
1984-01-01
The centricular catheter comprises a multiplicity of inlet microtubules. Each microtubule has both a large opening at its inlet end and a multiplicity of microscopic openings along its lateral surfaces. The microtubules are perforated by an ion beam sputter etch technique. The holes are etched in each microtubule by directing an ion beam through an electro formed mesh mask producing perforations having diameters ranging from about 14 microns to about 150 microns. This structure assures a reliable means for shunting cerebrospinal fluid from the cerebral ventricles to selected areas of the body.
Butterworth, C J; Rogers, S N
2017-12-01
This aim of this report is to describe the development and evolution of a new surgical technique for the immediate surgical reconstruction and rapid post-operative prosthodontic rehabilitation with a fixed dental prosthesis following low-level maxillectomy for malignant disease.The technique involves the use of a zygomatic oncology implant perforated micro-vascular soft tissue flap (ZIP flap) for the primary management of maxillary malignancy with surgical closure of the resultant maxillary defect and the installation of osseointegrated support for a zygomatic implant-supported maxillary fixed dental prosthesis.The use of this technique facilitates extremely rapid oral and dental rehabilitation within a few weeks of resective surgery, providing rapid return to function and restoring appearance following low-level maxillary resection, even in cases where radiotherapy is required as an adjuvant treatment post-operatively. The ZIP flap technique has been adopted as a standard procedure in the unit for the management of low-level maxillary malignancy, and this report provides a detailed step-by-step approach to treatment and discusses modifications developed over the treatment of an initial cohort of patients.
Small bowel obstruction following perforation of the uterus at induced abortion.
Nkor, S K; Igberase, G O; Osime, O C; Faleyimu, B L; Babalola, R
2009-01-01
Unsafe abortion is an important contributor to maternal morbidity and mortality. To present a case of small bowel obstruction following perforation of the uterus at induced abortion. A 36-year-old woman, presented at a private hospital, with abdominal pain and weight loss. She had full clinical assessment and laboratory investigations which indicated small bowel obstruction following perforation of the uterus at induced abortion, and was commenced on treatment. She was para 5+0. Her main complaints were abdominal and weight loss following induced abortion of a 12- week pregnancy, four months prior to presentation. At presentation the tools (ultrasound scan, plain abdominal radiograph and barium enema) used for diagnoses only suggested some form of intestinal obstruction and were unremarkable. Correct diagnoses indicating small bowel obstruction was only made at laparotomy. An exploratory laparotomy, adhesiolysis, small bowel resection, end to end anastomosis and bowel decompression was done after bowel preparation. Laparotomy has an enviable place in bowel injuries secondary to uterine perforation especially when there is a diagnostic dilemma. Nigerian female population requires continuous health education on widespread and effective use of contraception. Physicians need training and retraining on abortion techniques and management of abortion complications.
Preparation of Drosophila central neurons for in situ patch clamping.
Ryglewski, Stefanie; Duch, Carsten
2012-10-15
Short generation times and facile genetic techniques make the fruit fly Drosophila melanogaster an excellent genetic model in fundamental neuroscience research. Ion channels are the basis of all behavior since they mediate neuronal excitability. The first voltage gated ion channel cloned was the Drosophila voltage gated potassium channel Shaker(1,2). Toward understanding the role of ion channels and membrane excitability for nervous system function it is useful to combine powerful genetic tools available in Drosophila with in situ patch clamp recordings. For many years such recordings have been hampered by the small size of the Drosophila CNS. Furthermore, a robust sheath made of glia and collagen constituted obstacles for patch pipette access to central neurons. Removal of this sheath is a necessary precondition for patch clamp recordings from any neuron in the adult Drosophila CNS. In recent years scientists have been able to conduct in situ patch clamp recordings from neurons in the adult brain(3,4) and ventral nerve cord of embryonic(5,6), larval(7,8,9,10), and adult Drosophila(11,12,13,14). A stable giga-seal is the main precondition for a good patch and depends on clean contact of the patch pipette with the cell membrane to avoid leak currents. Therefore, for whole cell in situ patch clamp recordings from adult Drosophila neurons must be cleaned thoroughly. In the first step, the ganglionic sheath has to be treated enzymatically and mechanically removed to make the target cells accessible. In the second step, the cell membrane has to be polished so that no layer of glia, collagen or other material may disturb giga-seal formation. This article describes how to prepare an identified central neuron in the Drosophila ventral nerve cord, the flight motoneuron 5 (MN5(15)), for somatic whole cell patch clamp recordings. Identification and visibility of the neuron is achieved by targeted expression of GFP in MN5. We do not aim to explain the patch clamp technique itself.
Loff, Steffan; Wirth, Hartmut; Jester, Iwgo; Hosie, Stuart; Wollmann, Carmen; Schaible, Thomas; Ataman, Ozge; Waag, Karl-Ludwig
2005-11-01
Large defects in patients with congenital diaphragmatic hernia (CDH) are frequently closed with a polytetrafluoroethylene patch (PTFE). Intraoperative problems include lack of abdominal domain for the reduction of organs and closure of the abdominal wall. Main surgical postoperative complication is the recurrence of the hernia. We suggest a new and easy method of patch implantation, improving these problems, and report first follow-up results. In our clinic, 103 children with CDH were treated, and 87 children underwent reconstruction of the diaphragm in the 5 years between 1998 and 2002. In 52 patients, a patch implantation had to be performed. We have been optimizing our complete pediatric and surgical procedure and present a new standardized technique of preparation and implantation of a PTFE patch. The flat patch is folded to a 90 degrees cone. The cone is fixed in its form with few single stitches. It is implanted with an overlapping border of 1 cm circumferentially. The border is separately fixed with absorbable single stitches to keep from rolling up. The rough side of the patch points toward the rim of the diaphragm to enable ingrowth of the connective tissue. In a 1-year follow-up study, the recurrences in the 3 following groups of PTFE patches were studied: conventional implantation (simple patch without overlapping border), patch with separately fixed overlapping border, and cone-shaped patch with overlapping separately fixed border. Thirty-three patients were included in the study. After conventional PTFE-patch implantation, 6 (46%) of 13 patients developed reherniation. After PTFE-patch implantation with separately fixed overlapping border, 1 (11%) of 9 patients had a recurrent hernia. In the group with the PTFE-cone implantation, 1 (9%) of 11 patients developed a recurrence. Meanwhile, another 20 CDH patients received implantation of a cone-shaped patch, and no further recurrence occurred up to now. With the additional space (20 mL) provided by the cone-shaped patch, the closure of the abdomen was easier, and the fundus had intraoperatively a physiological position. This optimized patch implantation technique in large diaphragmatic defects offers considerable advantages especially regarding recurrence of the hernia and closure of the abdomen, which are currently the most challenging surgical problems. 1. The cone-shaped 3-dimensional patch increases abdominal capacity. 2. Redundant chest capacity is reduced, and the reconstructed diaphragm shows a physiological shape. 3. The dome of the patch allows a physiological position of the gastric fundus and a normal Hiss angle, thus preventing gastroesophageal reflux. 4. Additional safety of the implantation is achieved by separate fixation of the overlapping border of the cone, preventing recurrence.
Grambow, E; Heller, T; Wieneke, P; Weiß, C; Klar, E; Weinrich, M
2018-01-01
Duplex ultrasound is the first choice in diagnostics and surveillance of stenoses of the internal carotid arteries before and even after surgery. Therefore, the quality of duplex ultrasound is crucial to investigate these vascular pathologies. Aim of this study was the evaluation whether different surgical techniques affect the postoperative quality of duplex ultrasound. In a time period from January to May 2015 duplex ultrasound of the cervical vessels was performed in 75 patients after unilateral endarterectomy of the internal carotid artery at our department between 2006 and 2012. Thereby, the non-operated contralateral side served as a control. Study groups were defined by the surgical techniques of eversion- or thrombendarterectomy with patch plasty using different patch materials and/or a haemostatic sealant. Duplex ultrasound analysis included acoustic impedance, extinction of ultrasound, thickness of skin and individual anatomic aspects of the patients. Carotid endarterectomy itself reduced intravascular grey levels, skin thickness and increased extinction of duplex ultrasound when compared to the non-operated side of the neck. In contrast, neither the kind of chosen operative technique nor the use of different patch materials or the application of a haemostatic sealant showed an effect in this regards. Whereas carotid endarterectomy per se worsens the quality of postoperative duplex ultrasound, the different analysed surgical techniques as well as used patches and the application of a haemostatic sealant can be assumed to be equal regarding the quality of postoperative ultrasound.
Yue, Jin-feng; Qiao, Guan-hua; Liu, Ni; Nan, Fa-jun; Gao, Zhao-bing
2016-01-01
Aim: To establish an improved, high-throughput screening techniques for identifying novel KCNQ2 channel activators. Methods: KCNQ2 channels were stably expressed in CHO cells (KCNQ2 cells). Thallium flux assay was used for primary screening, and 384-well automated patch-clamp IonWorks Barracuda was used for hit validation. Two validated activators were characterized using a conventional patch-clamp recording technique. Results: From a collection of 80 000 compounds, the primary screening revealed a total of 565 compounds that potentiated the fluorescence signals in thallium flux assay by more than 150%. When the 565 hits were examined in IonWorks Barracuda, 38 compounds significantly enhanced the outward currents recorded in KCNQ2 cells, and were confirmed as KCNQ2 activators. In the conventional patch-clamp recordings, two validated activators ZG1732 and ZG2083 enhanced KCNQ2 currents with EC50 values of 1.04±0.18 μmol/L and 1.37±0.06 μmol/L, respectively. Conclusion: The combination of thallium flux assay and IonWorks Barracuda assay is an efficient high-throughput screening (HTS) route for discovering KCNQ2 activators. PMID:26725738
The Utility and Versatility of Perforator-Based Propeller Flaps in Burn Care.
Teven, Chad M; Mhlaba, Julie; O'Connor, Annemarie; Gottlieb, Lawrence J
The majority of surgical burn care involves the use of skin grafts. However, there are cases when flaps are required or provide superior outcomes both in the acute setting and for postburn reconstruction. Rarely discussed in the context of burn care, the perforator-based propeller flap is an important option to consider. We describe our experience with perforator-based propeller flaps in the acute and reconstructive phases of burn care. We reviewed demographics, indications, operative details, and outcomes for patients whose burn care included the use of a perforator-based propeller flap at our institution from May 2007 to April 2015. Details of the surgical technique and individual cases are also discussed. Twenty-one perforator-based propeller flaps were used in the care of 17 burn patients. Six flaps (29%) were used in the acute phase for coverage of exposed joints, tendons, cartilage, and bone; coverage of open wounds; and preservation of range of motion (ROM) by minimizing scar contracture. Fifteen flaps (71%) were used for reconstruction of postburn deformities including coverage of chronic wounds, for coverage after scar contracture release, and to improve ROM. The majority of flaps (94% at follow-up) exhibited stable soft tissue coverage and good or improved ROM of adjacent joints. Three cases of partial flap loss and one case of total flap loss occurred. Perforator-based propeller flaps provide reliable vascularized soft tissue for coverage of vital structures and wounds, contracture release, and preservation of ROM across joints. Despite a relatively significant risk of minor complications particularly in the coverage of chronic wounds, our study supports their utility in both the acute and reconstructive phases of burn care.
Microsurgical Resection of Suprasellar Craniopharyngioma-Technical Purview.
Nanda, Anil; Narayan, Vinayak; Mohammed, Nasser; Savardekar, Amey R; Patra, Devi Prasad
2018-04-01
Objectives Complete surgical resection is an important prognostic factor for recurrence and is the best management for craniopharyngioma. This operative video demonstrates the technical nuances in achieving complete resection of a suprasellar craniopharyngioma. Design and Setting The surgery was performed in a middle-aged lady who presented with the history of progressive bitemporal hemianopia and excessive sleepiness over 8 months. On imaging, suprasellar craniopharyngioma was identified. The tumor was approached through opticocarotid cistern and lamina terminalis. Exposure of bilateral optic nerves, right internal carotid artery, anterior cerebral artery, and its perforator branches was then afforded and the tumor was gross totally resected. Results The author demonstrates step-by-step technique of microsurgical resection of suprasellar craniopharyngioma. The narrow corridor to deeper structures, intricacies of multiple perforator vessels, and the technique of arachnoid and capsule dissection are the main challenging factors for the gross total resection of craniopharyngioma. The tumor portion which lies under the ipsilateral optic nerve is a blind spot region with a high chance of leaving residual tumor. Mobilization of optic nerve may endanger visual function too. The use of handheld mirror ['mirror-technique'] helps in better visualization of this blind spot and achieve complete excision. Conclusions The technical pearls of craniopharyngioma surgery include the optimum utilization of translamina terminalis route, wide opening of the cisterns, meticulous separation of deep perforator vessels, capsular mobilization/traction avoidance, and the use of "mirror-technique" for blind-spot visualization. These surgical strategies help to achieve complete resection without causing neurological deficit. The link to the video can be found at: https://youtu.be/9wHJ4AUpG50 .
Perforator Peroneal Artery Flap for Tongue Reconstruction.
Chauhan, Shubhra; Chavre, Sachin; Chandrashekar, Naveen Hedne; B S, Naveen
2017-03-01
Reconstruction has evolved long way from primary closure to flaps. As time evolved, better understanding of vascularity of flap has led to the development of innovative reconstructive techniques. These flaps can be raised from various parts of the body for reconstruction and have shown least donor site morbidity. We use one such peroneal artery perforator flap for tongue reconstruction with advantage of thin pliable flap, minimal donor site morbidity and hidden scar. Our patient 57yrs old lady underwent wide local excision with selective neck dissection. Perforators are marked about 10 and 15 cm inferiorly from the fibular head using hand held Doppler. Leg is positioned in such a way to give better exposure during dissection of the flap and flap is harvested under a tourniquet with pressure kept 350 mm Hg. The perforator is kept at the eccentric location, so as to gain length of the pedicle. Skin incison is placed over the peroneal muscle and deepened unto the deep facia, then the dissection is continued over the muscle and the perforator arising from the lateral septum. The proximal perforator about 10 cm from the fibular head is a constant perforator and bigger one, which is traced up to the peroneal vessel. We could get a 6 cm of pedicle length. Finally the flap is islanded on this perforator and the pedicle is ligated and flap harvested. Anastamosis was done to the ipsilateral side to facial vessels. The donor site is closed primarily and in the upper half one can harvest 5 cm width flap without requiring a skin graft along with a length of 8 to 12 cm. Various local and free flap has been used for reconstruction of partial tongue defects with its obvious donor site problems, like less pliable skin and not so adequate tissue from local flaps and sacrificing a important artery as in radial forearm flap serves as the work horse in reconstruction of partial tongue defects, Concept of super microsurgery was popularized by Japanese in 1980s and the concept of angiosome proposed by Taylor paved the way for development of new flaps. True perforator flaps are those where the source vessel is left undisturbed and overlying skin flap is raised. Yoshimura proposed cutaneous flap could be raised from peroneal artery (Br J Plast Surg 42:715-718, 1989). Wolff et al. (Plast Reconstr Surg 113:107-113, 2004) first used perforator based peroneal artery flap for oral reconstruction. Location of perforators vary, hence pre operative localisation can be done by ultrasound doppler, CT angio or MR angiography. Disadvantages over radial flap include varying anatomic location of perforators, need for imaging and difficult dissection of delicate vessels through muscles and hence a learning curve. Our patient had an arterial thrombus within few hours post-operatively which was successfully salvaged with immediate re-exploration and re-anastomosis of artery. Post-operative healing was uneventful and donor site was closed primarily without the need for graft. Perforator peroneal flap serves as a useful armamentarium for reconstruction of moderate size defects of tongue, buccal mucosa and floor of mouth with advantages of thin pliable flap, minimal donor site morbidity and hidden scar.
Management of excessive movable tissue: a modified impression technique.
Shum, Michael H C; Pow, Edmond H N
2014-08-01
Excessive movable tissue is a challenge in complete denture prosthetics. A modified impression technique is presented with polyvinyl siloxane impression material and a custom tray with relief areas and perforations in the area of the excessive movable tissue. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Rectangular Microstrip Antenna with Slot Embedded Geometry
NASA Astrophysics Data System (ADS)
Ambresh, P. A.; Hadalgi, P. M.; Hunagund, P. V.; Sujata, A. A.
2014-09-01
In this paper, a novel design that improves the performance of conventional rectangular microstrip antenna is discussed. Design adopts basic techniques such as probe feeding technique with rectangular inverted patch structure as superstrate, air filled dielectric medium as substrate and slot embedded patch. Prototype of the proposed antenna has been fabricated and various antenna performance parameters such as impedance bandwidth, return loss, radiation pattern and antenna gain are considered for Electromagnetic-study. The antennas are designed for the wireless application operating in the frequency range of 3.3 GHz to 3.6 GHz, and UK based fixed satellite service application (3 GHz to 4 GHz), and are named as single inverted patch conventional rectangular microstrip antenna (SIP-CRMSA) and slots embedded inverted patch rectangular microstrip antenna (SEIP-RMSA), respectively. Measurement outcomes for SEIP-RMSA1 and SEIP-RMSA2 showed the satisfactory performance with an achievable impedance bandwidth of 260 MHz (7 %) and 250 MHz (6.72 %), with return loss (RL) of -11.06 dB and -17.98 dB, achieved gain of 8.17 dB and 5.17 dB with 10% and 8% size reduction in comparison with the conventional patch antenna.
Plantar flaps based on perforators of the plantar metatarsal/common digital arteries.
Valentin, Georgescu Alexandru; Rodica, Matei Ileana; Manuel, Llusa
2014-09-01
Because of the unique characteristics of its integument, the affirmation "replacing like with like" becomes more than evident in the reconstruction of defects of the ultraspecialized plantar skin. But, the paucity of local resources, and especially in the forefoot, transforms this attempt in a very challenging problem. Many techniques, including skin grafts and various types of flaps were used in the management of defects in the forefoot. We present a new useful flap in the reconstruction of skin defects in the forefoot, based on small perforator vessels originating either from the plantar metatarsal arteries or plantar common digital arteries. Starting with June 2011, this flap was performed, as plantar transposition perforator flap, plantar propeller flap, or plantar propeller perforator plus flap, in seven patients with ulcers over the plantar forefoot. During a follow-up of 7 to 17 months (mean, 9.8 months), the local evolution regarding flap integration, pain, relapse, sensitive recovery, donor site, and footwear quality was analyzed. We registered a 100% survival rate of the flaps, with delayed healing in only one case. The gait resumption was possible after 6 weeks in all cases. This new flap, based on small perforator vessels from the plantar metatarsal or common digital arteries, and which provides a good, stable, and sensory recovery, seems to be a promising method in the reconstruction of plantar skin defects over the metatarsal heads. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
NASA Technical Reports Server (NTRS)
Volakis, J. L.; Kempel, L. C.; Sliva, R.; Wang, H. T. G.; Woo, A. G.
1994-01-01
The goal of this project was to develop analysis codes for computing the scattering and radiation of antennas on cylindrically and doubly conformal platforms. The finite element-boundary integral (FE-BI) method has been shown to accurately model the scattering and radiation of cavity-backed patch antennas. Unfortunately extension of this rigorous technique to coated or doubly curved platforms is cumbersome and inefficient. An alternative approximate approach is to employ an absorbing boundary condition (ABC) for terminating the finite element mesh thus avoiding use of a Green's function. A FE-ABC method is used to calculate the radar cross section (RCS) and radiation pattern of a cavity-backed patch antenna which is recessed within a metallic surface. It is shown that this approach is accurate for RCS and antenna pattern calculations with an ABC surface displaced as little as 0.3 lambda from the cavity aperture. These patch antennas may have a dielectric overlay which may also be modeled with this technique.
Hristov, Kiril L.; Parajuli, Shankar P.; Provence, Aaron
2016-01-01
In addition to improving sexual function, testosterone has been reported to have beneficial effects in ameliorating lower urinary tract symptoms by increasing bladder capacity and compliance, while decreasing bladder pressure. However, the cellular mechanisms by which testosterone regulates detrusor smooth muscle (DSM) excitability have not been elucidated. Here, we used amphotericin-B perforated whole cell patch-clamp and single channel recordings on inside-out excised membrane patches to investigate the regulatory role of testosterone in guinea pig DSM excitability. Testosterone (100 nM) significantly increased the depolarization-induced whole cell outward currents in DSM cells. The selective pharmacological inhibition of the large-conductance voltage- and Ca2+-activated K+ (BK) channels with paxilline (1 μM) completely abolished this stimulatory effect of testosterone, suggesting a mechanism involving BK channels. At a holding potential of −20 mV, DSM cells exhibited transient BK currents (TBKCs). Testosterone (100 nM) significantly increased TBKC activity in DSM cells. In current-clamp mode, testosterone (100 nM) significantly hyperpolarized the DSM cell resting membrane potential and increased spontaneous transient hyperpolarizations. Testosterone (100 nM) rapidly increased the single BK channel open probability in inside-out excised membrane patches from DSM cells, clearly suggesting a direct BK channel activation via a nongenomic mechanism. Live-cell Ca2+ imaging showed that testosterone (100 nM) caused a decrease in global intracellular Ca2+ concentration, consistent with testosterone-induced membrane hyperpolarization. In conclusion, the data provide compelling mechanistic evidence that under physiological conditions, testosterone at nanomolar concentrations directly activates BK channels in DSM cells, independent from genomic testosterone receptors, and thus regulates DSM excitability. PMID:27605581
Catamenial pneumothorax: a rare entity? Report of 5 cases and review of the literature
Visouli, Aikaterini N.; Darwiche, Kaid; Mpakas, Andreas; Papagiannis, Antonios; Tsakiridis, Kosmas; Machairiotis, Nikolaos; Stylianaki, Aikaterini; Katsikogiannis, Nikolaos; Courcoutsakis, Nicolaos; Zarogoulidis, Konstantinos
2012-01-01
Objective Spontaneous recurrent pneumothorax during menstruation is reported as catamenial pneumothorax. It is encountered in 3-6% of spontaneous pneumothorax cases among menstruating women. The percentage among women referred for surgery is significantly higher (25-30%). Although it usually involves the right-side (85-95%) it can be left-sided or bilateral. It is associated with diaphragmatic perforations and/or thoracic endometriosis. There is pelvic endometriosis in up to 30-51% of cases. The lesions that are not always found may present as small or larger holes at the central tendon of the diaphragm, as red, blueberry, brown spots or larger nodules at the diaphragm, the visceral or parietal pleura. Lesion histology may reveal endometriosis. We present 5 cases of catamenial pneumothorax treated surgically during the last 6 years. Patients and methods Five women, with a mean age of 34+/-9.9 years (median 38, range, 19-45 years) presented with right-sided recurrent catamenial pneumothorax. In 3 patients diaphragmatic perforation(s) were found; perforation suturing (n=1), and diaphragmatic plication reinforced with bovine pericardial patch (n=1) were performed. All patients underwent atypical resection of upper and/or middle lobe segments of lung parenchyma that appeared abnormal (haemorrhagic/emphysematous or blebs). Four patients underwent pleurodesis and 1 patient underwent pleurectomy. Four interventions were performed through video assisted thoracoscopic surgery, while diaphragmatic plication was performed through a video assisted mini-thoracotomy. Histology did not reveal endometriosis tissue. Results The postoperative course was uneventful. The patients were extubated in theatre and were discharged home at a mean of 7+/-4 days (median 6 days, range, 4-14 days). Two of them received hormonal therapy [Gonadotropin Releasing Hormone (GnRH) analogue] postoperatively. At a follow-up of 14.16 patient-years (mean 2.83+/-1.08 years, range, 1.33-3.83 years) there was recurrence, 6.5 months postoperatively, in one patient that had not undergone closure of a tiny diaphragmatic hole and had not received hormonal treatment postoperatively. She was treated medically (amenorrhea for 6 months with GnRH analogue) and had no further recurrences (in 3.3 years). Conclusions Surgery is the treatment of choice of catamenial pneumothorax. It should aim to complete management of all lesions. The most common complication is recurrence. Early diagnosis and multidisciplinary treatment including hormonal therapy may be beneficial in high risk patients. PMID:23304438
Generative adversarial networks for brain lesion detection
NASA Astrophysics Data System (ADS)
Alex, Varghese; Safwan, K. P. Mohammed; Chennamsetty, Sai Saketh; Krishnamurthi, Ganapathy
2017-02-01
Manual segmentation of brain lesions from Magnetic Resonance Images (MRI) is cumbersome and introduces errors due to inter-rater variability. This paper introduces a semi-supervised technique for detection of brain lesion from MRI using Generative Adversarial Networks (GANs). GANs comprises of a Generator network and a Discriminator network which are trained simultaneously with the objective of one bettering the other. The networks were trained using non lesion patches (n=13,000) from 4 different MR sequences. The network was trained on BraTS dataset and patches were extracted from regions excluding tumor region. The Generator network generates data by modeling the underlying probability distribution of the training data, (PData). The Discriminator learns the posterior probability P (Label Data) by classifying training data and generated data as "Real" or "Fake" respectively. The Generator upon learning the joint distribution, produces images/patches such that the performance of the Discriminator on them are random, i.e. P (Label Data = GeneratedData) = 0.5. During testing, the Discriminator assigns posterior probability values close to 0.5 for patches from non lesion regions, while patches centered on lesion arise from a different distribution (PLesion) and hence are assigned lower posterior probability value by the Discriminator. On the test set (n=14), the proposed technique achieves whole tumor dice score of 0.69, sensitivity of 91% and specificity of 59%. Additionally the generator network was capable of generating non lesion patches from various MR sequences.
Resonant frequencies of irregularly shaped microstrip antennas using method of moments
NASA Technical Reports Server (NTRS)
Deshpande, Manohar D.; Shively, David G.; Cockrell, C. R.
1993-01-01
This paper describes an application of the method of moments to determine resonant frequencies of irregularly shaped microstrip patches embedded in a grounded dielectric slab. For analysis, the microstrip patch is assumed to be excited by a linearly polarized plane wave that is normal to the patch. The surface-current density that is induced on the patch because of the incident field is expressed in terms of subdomain functions by dividing the patch into identical rectangular subdomains. The amplitudes of the subdomain functions, as a function of frequency, are determined using the electric-field integral equation (EFIE) approach in conjunction with the method of moments. The resonant frequencies of the patch are then obtained by selecting the frequency at which the amplitude of the surface-current density is real. The resonant frequencies of the equilateral triangular and other nonrectangular patches are computed using the present technique, and these frequencies are compared with measurements and other independent calculations.
Facilitated giga-seal formation with a just originated glass surface.
Böhle, T; Benndorf, K
1994-07-01
A simple technique of tip preparation in patch pipettes is described, which facilitates giga-seal formation. The pipettes were fabricated from thick-walled borosilicate glass tubing (external diameter 2.0 mm, internal diameter 0.5 mm) and the tips could be repeatedly broken in the bath. The pipette resistance correspondingly fell in steps of 3-20 M omega from about 80 M omega to about 2 M omega (double concentrated Tyrode). Scanning electron microscopy showed that the tip obtained after breaking was fairly plain. These broken tips were especially appropriate for patch-clamping. In cardiac myocytes in 11 out of 26 patches with Na+ channel activity, giga-seals developed spontaneously, i.e. without suction. In these patches the amplitude of the mean current with depolarizing pulses to -40 mV was significantly higher in comparison with patches formed under negative pressure. It is concluded that spontaneously sealed patches are most likely of planar configuration and the Na+ channel activity exceeds that in suction-induced patches.
The 'sniffer-patch' technique for detection of neurotransmitter release.
Allen, T G
1997-05-01
A wide variety of techniques have been employed for the detection and measurement of neurotransmitter release from biological preparations. Whilst many of these methods offer impressive levels of sensitivity, few are able to combine sensitivity with the necessary temporal and spatial resolution required to study quantal release from single cells. One detection method that is seeing a revival of interest and has the potential to fill this niche is the so-called 'sniffer-patch' technique. In this article, specific examples of the practical aspects of using this technique are discussed along with the procedures involved in calibrating these biosensors to extend their applications to provide quantitative, in addition to simple qualitative, measurements of quantal transmitter release.
NASA Astrophysics Data System (ADS)
Parvathi, S. P.; Ramanan, R. V.
2018-06-01
An iterative analytical trajectory design technique that includes perturbations in the departure phase of the interplanetary orbiter missions is proposed. The perturbations such as non-spherical gravity of Earth and the third body perturbations due to Sun and Moon are included in the analytical design process. In the design process, first the design is obtained using the iterative patched conic technique without including the perturbations and then modified to include the perturbations. The modification is based on, (i) backward analytical propagation of the state vector obtained from the iterative patched conic technique at the sphere of influence by including the perturbations, and (ii) quantification of deviations in the orbital elements at periapsis of the departure hyperbolic orbit. The orbital elements at the sphere of influence are changed to nullify the deviations at the periapsis. The analytical backward propagation is carried out using the linear approximation technique. The new analytical design technique, named as biased iterative patched conic technique, does not depend upon numerical integration and all computations are carried out using closed form expressions. The improved design is very close to the numerical design. The design analysis using the proposed technique provides a realistic insight into the mission aspects. Also, the proposed design is an excellent initial guess for numerical refinement and helps arrive at the four distinct design options for a given opportunity.
Manouguian, S; Abu-Aishah, N; Neitzel, J
1979-09-01
The experimental results of patch enlargement of the aortic and mitral valve rings with aortic and mitral double valve replacement are reported. The operative technique of this new surgical method is described and the indications are discussed.
Single-Layer, All-Metal Patch Antenna Element with Wide Bandwidth
NASA Technical Reports Server (NTRS)
Chamberlain, Neil F.; Hodges, Richard E.; Zawardzki, Mark S.
2012-01-01
It is known that the impedance at the center of a patch antenna element is a short circuit, implying that a wire or post can be connected from the patch to the groundplane at this point without impacting radiation performance. In principle, this central post can be used to support the patch element, thus eliminating the need for dielectric. In spaceborne applications, this approach is problematic because a patch element supported by a single, thin post is highly susceptible to acoustic loads during launch. The technology reported here uses a large-diameter center post as its supporting structure. The supporting structure allows for the fabrication of a sufficiently rigid antenna element that can survive launch loads. The post may be either hollow or solid, depending on fabrication approach and/or mass constraints. The patch antenna element and support post are envisioned as being fabricated (milled) from a single piece of aluminum or other metal. Alternately, the patch plate and support column can be fabricated separately and then joined using fasteners, adhesive, or welding. Casting and electroforming are also viable techniques for manufacturing the metal patch part(s). The patch structure is then either bonded or fastened to the supporting groundplane. Arrays of patch elements can be fabricated by attaching several structures to a common groundplane/support structure.
Label fusion based brain MR image segmentation via a latent selective model
NASA Astrophysics Data System (ADS)
Liu, Gang; Guo, Xiantang; Zhu, Kai; Liao, Hengxu
2018-04-01
Multi-atlas segmentation is an effective approach and increasingly popular for automatically labeling objects of interest in medical images. Recently, segmentation methods based on generative models and patch-based techniques have become the two principal branches of label fusion. However, these generative models and patch-based techniques are only loosely related, and the requirement for higher accuracy, faster segmentation, and robustness is always a great challenge. In this paper, we propose novel algorithm that combines the two branches using global weighted fusion strategy based on a patch latent selective model to perform segmentation of specific anatomical structures for human brain magnetic resonance (MR) images. In establishing this probabilistic model of label fusion between the target patch and patch dictionary, we explored the Kronecker delta function in the label prior, which is more suitable than other models, and designed a latent selective model as a membership prior to determine from which training patch the intensity and label of the target patch are generated at each spatial location. Because the image background is an equally important factor for segmentation, it is analyzed in label fusion procedure and we regard it as an isolated label to keep the same privilege between the background and the regions of interest. During label fusion with the global weighted fusion scheme, we use Bayesian inference and expectation maximization algorithm to estimate the labels of the target scan to produce the segmentation map. Experimental results indicate that the proposed algorithm is more accurate and robust than the other segmentation methods.
Contrast agent free detection of bowel perforation using chlorophyll derivatives from food plants
NASA Astrophysics Data System (ADS)
Han, Jung Hyun; Jo, Young Goun; Kim, Jung Chul; Lee, Jee-Bum; Kim, Yong-Chul; Kang, Hoonsoo; Hwang, In-Wook
2016-01-01
Chlorophylls occur abundantly in food plants and show bright emission bands at long-wavelength regions (∼675 and ∼720 nm) compared to the autofluorescence of animal organs and peritoneal fluids. The use of these emissions as biomarkers for monitoring bowel perforation with a modality that does not involve synthetic contrast agents seems promising. To validate this, we measured the fluorescence spectra of rat organs, human peritoneal and intestinal fluids, and human intestinal fluids diluted with physiological saline. The developed technique showed a high detection sensitivity (∼50 ppm) under irrigation for abdominal surgery, highlighting the potential of this tool in the surgical setting.
Intraluminal pressure response in Baerveldt tube shunts: a comparison of modification techniques.
Gilbert, David D; Bond, Brent
2007-01-01
To design an apparatus for in vitro quantification of effects of modifications to nonvalved tube shunts, and to compare the effects of these modifications done to prevent early postoperative hypotony. A testing apparatus was designed and constructed to measure intraluminal pressure (ILP) during constant infusion of balanced salt solution at 2 microL/min through Baerveldt tube shunts mounted on cadaver eyes. Three different modifications were performed and 3 shunts were used for each modification. The modifications were partial tube occlusion with a 3-0 Supramid suture, tube perforation with a 27-gauge needle on an occluded tube, and a 1.2 mm longitudinal venting slit on an occluded tube. The final steady state ILP for the 3-0 Supramid partially occluded tube ranged between 1.6 and 2.8 mm Hg over 3 trials with an average final steady state ILP of 2.0 mm Hg. The 27-gauge needle perforation produced ILPs of 4.6 to 8.2 mm Hg over 3 trials with an average final steady state pressure of 5.9 mm Hg. The 1.2 mm longitudinal venting slit produced an ILP range of 12.6 to 17.3 mm Hg over 3 trials with an average final steady state ILP of 14.8 mm Hg. The differences in final steady state ILP between the 3 modification techniques were statistically significant (P=0.00036). The 3-0 Supramid occlusion and the 27-gauge perforation techniques produced hypotony, whereas the 1.2 mm longitudinal venting slit produced acceptable pressures in vitro.
Saba, Luca; Atzeni, Matteo; Ribuffo, Diego; Mallarini, Giorgio; Suri, Jasjit S
2012-08-01
Our purpose was to compare two post-processing techniques, Maximum-Intensity-Projection (MIP) and Volume Rendering (VR) for the study of perforator arteries. Thirty patients who underwent Multi-Detector-Row CT Angiography (MDCTA) between February 2010 and May 2010 were retrospectively analyzed. For each patient and for each reconstruction method, the image quality was evaluated and the inter- and intra-observer agreement was calculated according to the Cohen statistics. The Hounsfield Unit (HU) value in the common femoral artery was quantified and the correlation (Pearson Statistic) between image quality and HU value was explored. The Pearson r between the right and left common femoral artery was excellent (r=0.955). The highest image quality score was obtained using MIP for both observers (total value 75, with a mean value 2.67 for observer 1 and total value of 79 and a mean value of 2.82 for observer 2). The highest agreement between the two observers was detected using the MIP protocol with a Cohen kappa value of 0.856. The ROC area under the curve (Az) for the VR is 0.786 (0.086 SD; p value=0.0009) whereas the ROC area under the curve (Az) for the MIP is 0.0928 (0.051 SD; p value=0.0001). MIP showed the optimal inter- and intra-observer agreement and the highest quality scores and therefore should be used as post-processing techniques in the analysis of perforating arteries. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
1974-08-31
chamber fluid, and gonioscopy exam (Conditions) With direct supervision (Criteria) In accordance with physician’s instructions (Consequence) Completion of...posterior chambers Gonioscopy techniques Slit-lamp biomicroscopy techniques Smear and culture techniques Accuracy in recording ard charting Manual...CILIARY BODY/ANGLE STRUCTURE TESTS I TASXS a. Assist with gonioscopy PERFO-RANCE OBJECTIVE (Stimulus) Upon physician’s orders (Behavior) The OPHTA
Retinal patching: a new approach to the management of selected retinal breaks.
Gilbert, C E; Grierson, I; McLeod, D
1989-01-01
Restoration of retinal continuity by a patching technique is proposed as a new means of treating selected rhegmatogenous retinal detachments where established techniques frequently fail. The patch consists of a substrate and adhesive applied to the inner surface of the retina surrounding the retinal break. Bovine eye cup experiments have been performed to explore the effectiveness of a range of adhesives, and cyanoacrylates and Tisseel have been found to be effective. Studies of these adhesives on confluent cultures of bovine retinal pigment epithelial cells and glia revealed temporary cyanoacrylate toxicity and stimulation of proliferation by Tisseel. Substrate biocompatability was investigated by observing the growth of cells on various substrates in tissue culture; biological substrates such as lens capsule supported cell growth whereas synthetic membranes only did so if pretreated with fibronectin.
NASA Technical Reports Server (NTRS)
James, W. P.
1971-01-01
A simplified procedure is presented for determining water current velocities and diffusion coefficients. Dye drops which form dye patches in the receiving water are made from an aircraft. The changes in position and size of the patches are recorded from two flights over the area. The simplified data processing procedure requires only that the ground coordinates about the dye patches be determined at the time of each flight. With an automatic recording coordinatograph for measuring coordinates and a computer for processing the data, this technique provides a practical method of determining circulation patterns and mixing characteristics of large aquatic systems. This information is useful in assessing the environmental impact of waste water discharges and for industrial plant siting.
Functional diversity response to hardwood forest management varies across taxa and spatial scales.
Murray, Bryan D; Holland, Jeffrey D; Summerville, Keith S; Dunning, John B; Saunders, Michael R; Jenkins, Michael A
2017-06-01
Contemporary forest management offers a trade-off between the potential positive effects of habitat heterogeneity on biodiversity, and the potential harm to mature forest communities caused by habitat loss and perforation of the forest canopy. While the response of taxonomic diversity to forest management has received a great deal of scrutiny, the response of functional diversity is largely unexplored. However, functional diversity may represent a more direct link between biodiversity and ecosystem function. To examine how forest management affects diversity at multiple spatial scales, we analyzed a long-term data set that captured changes in taxonomic and functional diversity of moths (Lepidoptera), longhorned beetles (Coleoptera: Cerambycidae), and breeding birds in response to contemporary silvicultural systems in oak-hickory hardwood forests. We used these data sets to address the following questions: how do even- and uneven-aged silvicultural systems affect taxonomic and functional diversity at the scale of managed landscapes compared to the individual harvested and unharvested forest patches that comprise the landscapes, and how do these silvicultural systems affect the functional similarity of assemblages at the scale of managed landscapes and patches? Due to increased heterogeneity within landscapes, we expected even-aged silviculture to increase and uneven-aged silviculture to decrease functional diversity at the landscape level regardless of impacts at the patch level. Functional diversity responses were taxon-specific with respect to the direction of change and time since harvest. Responses were also consistent across patch and landscape levels within each taxon. Moth assemblage species richness, functional richness, and functional divergence were negatively affected by harvesting, with stronger effects resulting from uneven-aged than even-aged management. Longhorned beetle assemblages exhibited a peak in species richness two years after harvesting, while functional diversity metrics did not differ between harvested and unharvested patches and managed landscapes. The species and functional richness of breeding bird assemblages increased in response to harvesting with more persistent effects in uneven- than in even-aged managed landscapes. For moth and bird assemblages, species turnover was driven by species with more extreme trait combinations. Our study highlights the variability of multi-taxon functional diversity in response to forest management across multiple spatial scales. © 2017 by the Ecological Society of America.
Spectrum of perforation peritonitis in delhi: 77 cases experience.
Yadav, Dinesh; Garg, Puneet K
2013-04-01
Perforation peritonitis is the most common surgical emergency encountered by surgeons all over the world as well in India. The spectrum of etiology of perforation peritonitis in tropical countries continues to differ from its western counterpart. This study was conducted at Hindu Rao Hospital, Municipal Corporation of Delhi, New Delhi, India, designed to highlight the spectrum of perforation peritonitis in the eastern countries and to improve its outcome. This prospective study included 77 consecutive patients of perforation peritonitis studied in terms of clinical presentations, causes, site of perforation, surgical treatment, postoperative complications, and mortality at Hindu Rao Hospital, Delhi, from March 1, 2011 to December 1, 2011, over a period of 8 months. All patients were resuscitated and underwent emergency exploratory laparotomy. On laparotomy cause of perforation peritonitis was found and controlled. The most common cause of perforation peritonitis noticed in our series was perforated duodenal ulcer (26.4 %) and ileal typhoid perforation (26.4 %), each followed by small bowel tuberculosis (10.3 %) and stomach perforation (9.2 %), perforation due to acute appendicitis (5 %). The highest number of perforations was seen in ileum (39.1 %), duodenum (26.4 %), stomach (11.5 %), appendix (3.5 %), jejunum (4.6 %), and colon (3.5 %). Overall mortality was 13 %. The spectrum of perforation peritonitis in India continuously differs from western countries. The highest number of perforations was noticed in the upper part of the gastrointestinal tract as compared to the western countries where the perforations seen mostly in the distal part. The most common cause of perforation peritonitis was perforated duodenal ulcer and small bowel typhoid perforation followed by typhoid perforation. Large bowel perforations and malignant perforations were least common in our setup.
Parameter estimation in a structural acoustic system with fully nonlinear coupling conditions
NASA Technical Reports Server (NTRS)
Banks, H. T.; Smith, Ralph C.
1994-01-01
A methodology for estimating physical parameters in a class of structural acoustic systems is presented. The general model under consideration consists of an interior cavity which is separated from an exterior noise source by an enclosing elastic structure. Piezoceramic patches are bonded to or embedded in the structure; these can be used both as actuators and sensors in applications ranging from the control of interior noise levels to the determination of structural flaws through nondestructive evaluation techniques. The presence and excitation of patches, however, changes the geometry and material properties of the structure as well as involves unknown patch parameters, thus necessitating the development of parameter estimation techniques which are applicable in this coupled setting. In developing a framework for approximation, parameter estimation and implementation, strong consideration is given to the fact that the input operator is unbonded due to the discrete nature of the patches. Moreover, the model is weakly nonlinear. As a result of the coupling mechanism between the structural vibrations and the interior acoustic dynamics. Within this context, an illustrating model is given, well-posedness and approximations results are discussed and an applicable parameter estimation methodology is presented. The scheme is then illustrated through several numerical examples with simulations modeling a variety of commonly used structural acoustic techniques for systems excitations and data collection.
Zhang, Xuan; An, Hailong; Li, Junwei; Zhang, Yuanyuan; Liu, Yang; Jia, Zhanfeng; Zhang, Wei
2016-01-01
Background and Purpose Kv7 (Kv7.1–7.5) channels play an important role in the regulation of neuronal excitability and the cardiac action potential. Growing evidence suggests Kv7.4/Kv7.5 channels play a crucial role in regulating vascular smooth muscle contractility. Most of the reported Kv7 openers have shown poor selectivity across these five subtypes. In this study, fasudil – a drug used for cerebral vasospasm – has been found to be a selective opener of Kv7.4/Kv7.5 channels. Experimental Approach A perforated whole‐cell patch technique was used to record the currents and membrane potential. Homology modelling and a docking technique were used to investigate the interaction between fasudil and the Kv7.4 channel. An isometric tension recording technique was used to assess the vascular tension. Key Results Fasudil selectively and potently enhanced Kv7.4 and Kv7.4/Kv7.5 currents expressed in HEK293 cells, and shifted the voltage‐dependent activation curve in a more negative direction. Fasudil did not affect either Kv7.2 and Kv7.2/Kv7.3 currents expressed in HEK293 cells, the native neuronal M‐type K+ currents, or the resting membrane potential in small rat dorsal root ganglia neurons. The Val248 in S5 and Ile308 in S6 segment of Kv7.4 were critical for this activating effect of fasudil. Fasudil relaxed precontracted rat small arteries in a concentration‐dependent fashion; this effect was antagonized by the Kv7 channel blocker XE991. Conclusions and Implications These results suggest that fasudil is a selective Kv7.4/Kv7.5 channel opener and provide a new dimension for developing selective Kv7 modulators and a new prospective for the use, action and mechanism of fasudil. PMID:27677924
NASA Technical Reports Server (NTRS)
Maskew, B.
1979-01-01
The description of the modified code includes details of a doublet subpanel technique in which panels that are close to a velocity calculation point are replaced by a subpanel set. This treatment gives the effect of a higher panel density without increasing the number of unknowns. In particular, the technique removes the close approach problem of the earlier singularity model in which distortions occur in the detailed pressure calculation near panel corners. Removal of this problem allowed a complete wake relaxation and roll-up iterative procedure to be installed in the code. The geometry package developed for the new technique and also for the more general configurations is based on a multiple patch scheme. Each patch has a regular array of panels, but arbitrary relationships are allowed between neighboring panels at the edges of adjacent patches. This provides great versatility for treating general configurations.
Free-style puzzle flap: the concept of recycling a perforator flap.
Feng, Kuan-Ming; Hsieh, Ching-Hua; Jeng, Seng-Feng
2013-02-01
Theoretically, a flap can be supplied by any perforator based on the angiosome theory. In this study, the technique of free-style perforator flap dissection was used to harvest a pedicled or free skin flap from a previous free flap for a second difficult reconstruction. The authors call this a free-style puzzle flap. For the past 3 years, the authors treated 13 patients in whom 12 pedicled free-style puzzle flaps were harvested from previous redundant free flaps and recycled to reconstruct soft-tissue defects at various anatomical locations. One free-style free puzzle flap was harvested from a previous anterolateral thigh flap for buccal cancer to reconstruct a foot defect. Total flap survival was attained in 12 of 13 flaps. One transferred flap failed completely. This patient had received postoperative radiotherapy after the initial cancer ablation and free anterolateral thigh flap reconstruction. Another free flap was used to close and reconstruct the wound. All the donor sites could be closed primarily. The free-style puzzle flap, harvested from a previous redundant free flap and used as a perforator flap to reconstruct a new defect, has proven to be versatile and reliable. When indicated, it is an alternative donor site for further reconstruction of soft-tissue defects.
The "Tokyo" consensus on propeller flaps.
Pignatti, Marco; Ogawa, Rei; Hallock, Geoffrey G; Mateev, Musa; Georgescu, Alexandru V; Balakrishnan, Govindasamy; Ono, Shimpei; Cubison, Tania C S; D'Arpa, Salvatore; Koshima, Isao; Hyakusoku, Hikko
2011-02-01
Over the past few years, the use of propeller flaps, which base their blood supply on subcutaneous tissue or isolated perforators, has become increasingly popular. Because no consensus has yet been reached on terminology and nomenclature of the propeller flap, different and confusing uses of the term can be found in the literature. In this article, the authors report the consensus on the definition and classification of propeller flaps reached by the authors that gathered at the First Tokyo Meeting on Perforator and Propeller Flaps in June of 2009. Some peculiar aspects of the surgical technique are discussed. A propeller flap can be defined as an "island flap that reaches the recipient site through an axial rotation." The classification is based on the nourishing pedicle (subcutaneous pedicled propeller flap, perforator pedicled propeller flap, supercharged propeller flap), the degrees of skin island rotation (90 to 180 degrees) and, when possible, the artery of origin of the perforator. The propeller flap is a useful reconstructive tool that can achieve good cosmetic and functional results. A flap should be called a propeller flap only if it fulfils the definition above. The type of nourishing pedicle, the source vessel (when known), and the degree of skin island rotation should be specified for each flap.
Lundblad, Runar; Abdelnoor, Michel; Svennevig, Jan Ludvig
2004-09-01
Simple linear resection and endoventricular patch plasty are alternative techniques to repair postinfarction left ventricular aneurysm. The aim of the study was to compare these 2 methods with regard to early mortality and long-term survival. We retrospectively reviewed 159 patients undergoing operations between 1989 and 2003. The epidemiologic design was of an exposed (simple linear repair, n = 74) versus nonexposed (endoventricular patch plasty, n = 85) cohort with 2 endpoints: early mortality and long-term survival. The crude effect of aneurysm repair technique versus endpoint was estimated by odds ratio, rate ratio, or relative risk and their 95% confidence intervals. Stratification analysis by using the Mantel-Haenszel method was done to quantify confounders and pinpoint effect modifiers. Adjustment for multiconfounders was performed by using logistic regression and Cox regression analysis. Survival curves were analyzed with the Breslow test and the log-rank test. Early mortality was 8.2% for all patients, 13.5% after linear repair and 3.5% after endoventricular patch plasty. When adjusted for multiconfounders, the risk of early mortality was significantly higher after simple linear repair than after endoventricular patch plasty (odds ratio, 4.4; 95% confidence interval, 1.1-17.8). Mean follow-up was 5.8 +/- 3.8 years (range, 0-14.0 years). Overall 5-year cumulative survival was 78%, 70.1% after linear repair and 91.4% after endoventricular patch plasty. The risk of total mortality was significantly higher after linear repair than after endoventricular patch plasty when controlled for multiconfounders (relative risk, 4.5; 95% confidence interval, 2.0-9.7). Linear repair dominated early in the series and patch plasty dominated later, giving a possible learning-curve bias in favor of patch plasty that could not be adjusted for in the regression analysis. Postinfarction left ventricular aneurysm can be repaired with satisfactory early and late results. Surgical risk was lower and long-term survival was higher after endoventricular patch plasty than simple linear repair. Differences in outcome should be interpreted with care because of the retrospective study design and the chronology of the 2 repair methods.
The rationale for intensity-modulated proton therapy in geometrically challenging cases
NASA Astrophysics Data System (ADS)
Safai, S.; Trofimov, A.; Adams, J. A.; Engelsman, M.; Bortfeld, T.
2013-09-01
Intensity-modulated proton therapy (IMPT) delivered with beam scanning is currently available at a limited number of proton centers. However, a simplified form of IMPT, the technique of field ‘patching’, has long been a standard practice in proton therapy centers. In field patching, different parts of the target volume are treated from different directions, i.e., a part of the tumor gets either full dose from a radiation field, or almost no dose. Thus, patching represents a form of binary intensity modulation. This study explores the limitations of the standard binary field patching technique, and evaluates possible dosimetric advantages of continuous dose modulations in IMPT. Specifics of the beam delivery technology, i.e., pencil beam scanning versus passive scattering and modulation, are not investigated. We have identified two geometries of target volumes and organs at risk (OAR) in which the use of field patching is severely challenged. We focused our investigations on two patient cases that exhibit these geometries: a paraspinal tumor case and a skull-base case. For those cases we performed treatment planning comparisons of three-dimensional conformal proton therapy (3DCPT) with field patching versus IMPT, using commercial and in-house software, respectively. We also analyzed the robustness of the resulting plans with respect to systematic setup errors of ±1 mm and range errors of ±2.5 mm. IMPT is able to better spare OAR while providing superior dose coverage for the challenging cases identified above. Both 3DCPT and IMPT are sensitive to setup errors and range uncertainties, with IMPT showing the largest effect. Nevertheless, when delivery uncertainties are taken into account IMPT plans remain superior regarding target coverage and OAR sparing. On the other hand, some clinical goals, such as the maximum dose to OAR, are more likely to be unmet with IMPT under large range errors. IMPT can potentially improve target coverage and OAR sparing in challenging cases, even when compared with the relatively complicated and time consuming field patching technique. While IMPT plans tend to be more sensitive to delivery uncertainties, their dosimetric advantage generally holds. Robust treatment planning techniques may further reduce the sensitivity of IMPT plans.
Outcomes of using a sutureless bovine pericardial patch graft for Ahmed glaucoma valve implantation.
Quaranta, Luciano; Riva, Ivano; Floriani, Irene C
2013-01-01
To evaluate the long-term outcomes of a surgical technique using a sutureless bovine pericardial patch graft for the implantation of an Ahmed glaucoma valve (AGV). This was a pilot study on patients with primary open-angle glaucoma refractory to repeated surgical filtering procedures. All patients underwent AGV implant technique using a sutureless bovine pericardial patch graft. The pericardial membrane was cut using an ordinary corneal trephine with a diameter of 9.0 or 10.0 mm. The anterior part of the tube was covered with the graft and kept in place with fibrin glue. Subsequently, the cap was stitched all around the tube and the dissected conjunctiva was laid over it. Intraocular pressure (IOP) and complications were evaluated 1 week and 1, 3, 6, 12, and 24 months after surgery. The procedure was used to treat 20 eyes of 20 consecutive patients (12 men and 8 women: mean age [SD] 64.8 [7.8] years). Mean IOP was 28.1 mm Hg (SD 4.9) at baseline and decreased to 14.9 mm Hg (SD 1.5) 24 months after surgery (p<0.001). The overall mean number of topical medications was 3.1 (SD 0.5) at baseline and decreased to 1.4 (SD 0.8) after 24 months (p<0.001). During follow-up, there was no conjunctival erosion, thinning of pericardial patch graft over the tube, or tube exposure; no signs of endophthalmitis were recorded. The results suggest that the sutureless technique using a bovine pericardial graft patch is a safe and rapid procedure for AGV implantation.
In vivo laser assisted end-to-end anastomosis with ICG-infused chitosan patches
NASA Astrophysics Data System (ADS)
Rossi, Francesca; Matteini, Paolo; Esposito, Giuseppe; Scerrati, Alba; Albanese, Alessio; Puca, Alfredo; Maira, Giulio; Rossi, Giacomo; Pini, Roberto
2011-07-01
Laser assisted vascular repair is a new optimized technique based on the use of ICG-infused chitosan patch to close a vessel wound, with or even without few supporting single stitches. We present an in vivo experimental study on an innovative end-to-end laser assisted vascular anastomotic (LAVA) technique, performed with the application of ICGinfused chitosan patches. The photostability and the mechanical properties of ICG-infused chitosan films were preliminary measured. The in vivo study was performed in 10 New Zealand rabbits. After anesthesia, a 3-cm segment of the right common carotid artery was exposed, thus clamped proximally and distally. The artery was then interrupted by means of a full thickness cut. Three single microsutures were used to approximate the two vessel edges. The ICG-infused chitosan patch was rolled all over the anastomotic site and welded by the use of a diode laser emitting at 810 nm and equipped with a 300 μm diameter optical fiber. Welding was obtained by delivering single laser spots to induce local patch/tissue adhesion. The result was an immediate closure of the anastomosis, with no bleeding at clamps release. Thus animals underwent different follow-up periods, in order to evaluate the welded vessels over time. At follow-up examinations, all the anastomoses were patent and no bleeding signs were documented. Samples of welded vessels underwent histological examinations. Results showed that this technique offer several advantages over conventional suturing methods: simplification of the surgical procedure, shortening of the operative time, better re-endothelization and optimal vascular healing process.
NASA Astrophysics Data System (ADS)
Ghasemi-Nejhad, Mehrdad N.; Pourjalali, Saeid
2003-08-01
This work presents manufacturing and testing of active composite panels (ACPs) with embedded piezoelectric sensors and actuators. The composite material employed here is a plain weave carbon epoxy prepreg fabric with about 0.33 mm ply thickness. The piezoelectric patches employed here are Continuum Control Corporation, CCC, (recently Continuum Photonics, Inc) active fiber composite patches with 0.33 mm thickness, i.e. close to the composite ply thickness. Composite cut-out layers are used to fill the space around the embedded piezoelectric patches to minimize the problems associated with ply drops in composites. The piezoelectric patches were embedded inside the composite laminate. High-temperature wires were soldered to the piezoelectric leads, insulated from the carbon substructure by high-temperature materials, and were taken out of the composite laminates employing a molded-in hole technique that reduces the stress concentration as opposed to a drilled hole, and thereby enhancing the performance of the composite structure. The laminated ACP"s were co-cured inside an autoclave employing the cure cycle recommended by the composite material supplier. The curie temperature of the embedded piezoelectric patches should be well above the curing temperature of the composite materials as was the case here. The manufactured ACP beams and plates were trimmed and then tested for their functionality. Vibration suppression as well as simultaneous vibration suppression and precision positioning tests, using PID control as well as Hybrid Adaptive Control techniques were successfully conducted on the manufactured ACP beams and their functionality were demonstrated. Recommendations on the use of this embedding technique for ACPs are provided.
Preparation of active 3D film patches via aligned fiber electrohydrodynamic (EHD) printing
NASA Astrophysics Data System (ADS)
Wang, Jun-Chuan; Zheng, Hongxia; Chang, Ming-Wei; Ahmad, Zeeshan; Li, Jing-Song
2017-03-01
The design, preparation and application of three-dimensional (3D) printed structures have gained appreciable interest in recent times, particularly for drug dosage development. In this study, the electrohydrodynamic (EHD) printing technique was developed to fabricate aligned-fiber antibiotic (tetracycline hydrochloride, TE-HCL) patches using polycaprolactone (PCL), polyvinyl pyrrolidone (PVP) and their composite system (PVP-PCL). Drug loaded 3D patches possessed perfectly aligned fibers giving rise to fibrous strut orientation, variable inter-strut pore size and controlled film width (via layering). The effect of operating parameters on fiber deposition and alignment were explored, and the impact of the film structure, composition and drug loading was evaluated. FTIR demonstrated successful TE-HCL encapsulation in aligned fibers. Patches prepared using PVP and TE-HCL displayed enhanced hydrophobicity. Tensile tests exhibited changes to mechanical properties arising from additive effects. Release of antibiotic from PCL-PVP dosage forms was shown over 5 days and was slower compared to pure PCL or PVP. The printed patch void size also influenced antibiotic release behavior. The EHDA printing technique provides an exciting opportunity to tailor dosage forms in a single-step with minimal excipients and operations. These developments are crucial to meet demands where dosage forms cannot be manufactured rapidly or when a personalized approach is required.
Preparation of active 3D film patches via aligned fiber electrohydrodynamic (EHD) printing
Wang, Jun-Chuan; Zheng, Hongxia; Chang, Ming-Wei; Ahmad, Zeeshan; Li, Jing-Song
2017-01-01
The design, preparation and application of three-dimensional (3D) printed structures have gained appreciable interest in recent times, particularly for drug dosage development. In this study, the electrohydrodynamic (EHD) printing technique was developed to fabricate aligned-fiber antibiotic (tetracycline hydrochloride, TE-HCL) patches using polycaprolactone (PCL), polyvinyl pyrrolidone (PVP) and their composite system (PVP-PCL). Drug loaded 3D patches possessed perfectly aligned fibers giving rise to fibrous strut orientation, variable inter-strut pore size and controlled film width (via layering). The effect of operating parameters on fiber deposition and alignment were explored, and the impact of the film structure, composition and drug loading was evaluated. FTIR demonstrated successful TE-HCL encapsulation in aligned fibers. Patches prepared using PVP and TE-HCL displayed enhanced hydrophobicity. Tensile tests exhibited changes to mechanical properties arising from additive effects. Release of antibiotic from PCL-PVP dosage forms was shown over 5 days and was slower compared to pure PCL or PVP. The printed patch void size also influenced antibiotic release behavior. The EHDA printing technique provides an exciting opportunity to tailor dosage forms in a single-step with minimal excipients and operations. These developments are crucial to meet demands where dosage forms cannot be manufactured rapidly or when a personalized approach is required. PMID:28272513
Wei, Jiao; Herrler, Tanja; Gu, Bin; Yang, Mei; Li, Qingfeng; Dai, Chuanchang; Xie, Feng
2018-05-01
The repair of extensive upper limb skin lesions in pediatric patients is extremely challenging due to substantial limitations of flap size and donor-site morbidity. We aimed to create an oversize preexpanded flap based on intercostal artery perforators for large-scale resurfacing of the upper extremity in children. Between March 2013 and August 2016, 11 patients underwent reconstructive treatment for extensive skin lesions in the upper extremity using a preexpanded intercostal artery perforator flap. Preoperatively, 2 to 4 candidate perforators were selected as potential pedicle vessels based on duplex ultrasound examination. After tissue expander implantation in the thoracodorsal area, regular saline injections were performed until the expanded flap was sufficient in size. Then, a pedicled flap was formed to resurface the skin lesion of the upper limb. The pedicles were transected 3 weeks after flap transfer. Flap survival, complications, and long-term outcome were evaluated. The average time of tissue expansion was 133 days with a mean final volume of 1713 mL. The thoracoabdominal flaps were based on 2 to 6 pedicles and used to resurface a mean skin defect area of 238 cm ranging from 180 to 357 cm. In all cases, primary donor-site closure was achieved. Marginal necrosis was seen in 5 cases. The reconstructed limbs showed satisfactory outcome in both aesthetic and functional aspects. The preexpanded intercostal artery perforator flap enables 1-block repair of extensive upper limb skin lesions. Due to limited donor-site morbidity and a pedicled technique, this resurfacing approach represents a useful tool especially in pediatric patients.
Visvanathan, Vikranth; Vallamkondu, Vamsidhar; Bhimrao, Sanjiv K
2018-06-01
Objectives Surgical repair of a tympanic membrane perforation is a common otologic procedure. However, achieving a successful closure can be challenging, especially if the anterior margin of the tympanic membrane is involved. The aim of this study was to systematically review the literature on evidence published in closure of anterior tympanic membrane perforations. Data Sources The following data sources were searched: Cochrane Central Register of Controlled Trials (1997 to August, 3 2017), MEDLINE (February 1948 to August 3, 2017), and Embase (1975 to August 3, 2017). Data Extraction Two authors independently reviewed titles and abstracts. The PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-analyses) guidelines were followed. For the purpose of this study, the inclusion criteria were as follows; (1) studies reporting surgical technique for closure of anterior tympanic membrane perforations, (2) primary cases only, (3) articles published in the English language, (4) minimum 6-month follow-up, and (5) recorded pre- and postoperative audiometry. The exclusion criteria were non-English language articles, revision surgery, and no audiometric outcomes. Results On initial search, a total of 181 articles were identified (PubMed, n = 136; Cochrane, n = 28; Embase, n = 17). Based on the criteria, 136 articles were excluded. Full text of 45 articles was reviewed, and a further 24 articles were excluded. A total of 21 articles fulfilled the criteria for study inclusion. Conclusions All published evidence is level 4. High-quality controlled studies are required to determine the most effective method for closure of anterior tympanic membrane perforation.
Long-term outcome of large artificial patch aortic repair for diffuse stenosis in Williams syndrome.
Sughimoto, Koichi; Takahara, Yoshiharu; Mogi, Kenji; Sakurai, Manabu; Aoki, Chikashi
2010-10-01
There have been only a few reports concerning the long-term results of a surgical procedure using a large artificial patch for patients with Williams syndrome. Twelve years have passed since a patient with William's syndrome underwent a surgery with a patch angioplasty for the diffuse supravalvular aortic stenosis and deformities of the neck branch arteries. The patient had a well-balanced aortic growth without stenotic or aneurysmal changes, which was confirmed during the time of the second surgery when replacing the mitral valve. This technique of using a large patch has proven to be safe for Williams syndrome patients with diffuse supravalvular aortic stenosis in the long term.
Spectrum of perforation peritonitis in Pakistan: 300 cases Eastern experience.
Afridi, Shahida Parveen; Malik, Faiza; Ur-Rahman, Shafiq; Shamim, Shahid; Samo, Khursheed A
2008-11-08
Perforation peritonitis is the most common surgical emergency encountered by the surgeons all over the world as well in Pakistan. The spectrum of etiology of perforation peritonitis in tropical countries continues to differ from its western counter part. This study was conducted at Dow University of health sciences and Civil Hospital Karachi (DUHS & CHK) Pakistan, designed to highlight the spectrum of perforation peritonitis in the East and to improve its outcome. A prospective study includes three hundred consecutive patients of perforation peritonitis studied in terms of clinical presentations, Causes, site of perforation, surgical treatment, post operative complications and mortality, at (DUHS&CHK) Pakistan, from 1st September 2005 - 1st March 2008, over a period of two and half years. All patients were resuscitated underwent emergency exploratory laparotomy. On laparotomy cause of perforation peritonitis was found and controlled. The most common cause of perforation peritonitis noticed in our series was acid peptic disease 45%, perforated duodenal ulcer (43.6%) and gastric ulcer 1.3%. followed by small bowel tuberculosis (21%) and typhoid (17%). large bowel perforation due to tuberculosis 5%, malignancy 2.6% and volvulus 0.3%. Perforation due to acute appendicitis (5%). Highest number of perforations has seen in the duodenum 43.6%, ileum37.6%, and colon 8%, appendix 5%, jejunum 3.3%, and stomach 2.3%. Overall mortality was (10.6%). The spectrum of perforation peritonitis in Pakistan continuously differs from western country. Highest number of perforations noticed in the upper part of the gastrointestinal tract as compared to the western countries where the perforations seen mostly in the distal part. Most common cause of perforation peritonitis is perforated duodenal ulcer, followed by small bowel tuberculosis and typhoid perforation. Majority of the large bowel perforations are also tubercular. Malignant perforations are least common in our setup.
NASA Astrophysics Data System (ADS)
Alexander, Cici; Korstjens, Amanda H.; Hill, Ross A.
2017-03-01
Mapping and monitoring tropical rainforests and quantifying their carbon stocks are important, both for devising strategies for their conservation and mitigating the effects of climate change. Airborne Laser Scanning (ALS) has advantages over other remote sensing techniques for describing the three-dimensional structure of forests. This study identifies forest patches using ALS-based structural attributes in a tropical rainforest in Sumatra, Indonesia. A method to group trees with similar attributes into forest patches based on Thiessen polygons and k-medoids clustering is developed, combining the advantages of both raster and individual tree-based methods. The structural composition of the patches could be an indicator of habitat type and quality. The patches could also be a basis for developing allometric models for more accurate estimation of carbon stock than is currently possible with generalised models.
Proximal gastric vagotomy: does it have a place in the future management of peptic ulcer?
Johnson, A G
2000-03-01
Proximal gastric vagotomy (PGV) is a modification of truncal vagotomy, which was introduced by Dragstedt for the treatment of duodenal ulcer (DU) in 1943. It is a technically demanding operation; but when performed by an experienced surgeon, it is safe and gives a cure rate for DU of more than 90%, with minimal side effects. The operation permanently alters the natural history of the disease and may be used for gastric ulcer (GU), with ulcer excision; but it is not as effective. Further adaptations, such as posterior truncal vagotomy with anterior seromyotomy, were introduced to simplify and shorten the operation, but they did not receive wide acceptance. Recently, with the identification of Helicobacter, it was found that DU can also be cured by eliminating the infection. PGV is therefore used electively in patients with persistent DU that is not Helicobacter-positive or in the few in whom Helicobacter cannot be eliminated. In patients with bleeding or perforated DUs, PGV may be used in conjunction with underrunning the vessel or patching the perforation. However, few surgeons doing emergency peptic ulcer surgery have experience with PGV, so simple suture followed by medical treatment is the safest option. Because elective PGV is now a rare procedure, patients should be referred to a center with special expertise. If Helicobacter becomes resistant to antibiotics in the future, surgery may be needed regularly again, but the technical nuances would have to be learned.
Cellular mechanisms of desynchronizing effects of hypothermia in an in vitro epilepsy model.
Motamedi, Gholam K; Gonzalez-Sulser, Alfredo; Dzakpasu, Rhonda; Vicini, Stefano
2012-01-01
Hypothermia can terminate epileptiform discharges in vitro and in vivo epilepsy models. Hypothermia is becoming a standard treatment for brain injury in infants with perinatal hypoxic ischemic encephalopathy, and it is gaining ground as a potential treatment in patients with drug resistant epilepsy. However, the exact mechanism of action of cooling the brain tissue is unclear. We have studied the 4-aminopyridine model of epilepsy in mice using single- and dual-patch clamp and perforated multi-electrode array recordings from the hippocampus and cortex. Cooling consistently terminated 4-aminopyridine induced epileptiform-like discharges in hippocampal neurons and increased input resistance that was not mimicked by transient receptor potential channel antagonists. Dual-patch clamp recordings showed significant synchrony between distant CA1 and CA3 pyramidal neurons, but less so between the pyramidal neurons and interneurons. In CA1 and CA3 neurons, hypothermia blocked rhythmic action potential discharges and disrupted their synchrony; however, in interneurons, hypothermia blocked rhythmic discharges without abolishing action potentials. In parallel, multi-electrode array recordings showed that synchronized discharges were disrupted by hypothermia, whereas multi-unit activity was unaffected. The differential effect of cooling on transmitting or secreting γ-aminobutyric acid interneurons might disrupt normal network synchrony, aborting the epileptiform discharges. Moreover, the persistence of action potential firing in interneurons would have additional antiepileptic effects through tonic γ-aminobutyric acid release.
Kwon, Kye Yoon; Ji, Yong Woo; Lee, Jeihoon; Kim, Eung Kweon
2016-07-18
Surgical lifting and scraping is a well-known treatment for epithelial ingrowth, but treatment for epithelial ingrowth on the centrally perforated laser in situ keratomileusis (LASIK) flap has not been well studied. We present a patient who had epithelial ingrowth to the backside of the flap through a central LASIK flap laceration with a stellate shape. The patient had undergone uncomplicated bilateral LASIK surgery 3 years before the trauma. Because the epithelial ingrowth was suspected during the first visit 2 weeks after trauma, and definite epithelial ingrowth was noted during the additional 2 week observation period, the ingrown epithelial tissue was removed mechanically with a number 15 blade after lifting of the flap 4 weeks after the trauma. An amniotic membrane overlay was applied over the cornea and was sutured tightly to the episclera to firmly press down the flap to the remaining posterior stroma, to prevent growth of the epithelium again to the backside of the flap. At the last follow-up visit, 5 months after surgery, the patient's visual acuity remained stabilized with no sign of recurrent epithelial ingrowth. These results showed that an amniotic membrane patch can be a useful adjuvant in the treatment of epithelial ingrowth, even on the central stellate laceration of the LASIK flap over the visual axis.
TH-CD-206-09: Learning-Based MRI-CT Prostate Registration Using Spare Patch-Deformation Dictionary
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, X; Jani, A; Rossi, P
Purpose: To enable MRI-guided prostate radiotherapy, MRI-CT deformable registration is required to map the MRI-defined tumor and key organ contours onto the CT images. Due to the intrinsic differences in grey-level intensity characteristics between MRI and CT images, the integration of MRI into CT-based radiotherapy is very challenging. We are developing a learning-based registration approach to address this technical challenge. Methods: We propose to estimate the deformation between MRI and CT images in a patch-wise fashion by using the sparse representation technique. Specifically, we assume that two image patches should follow the same deformation if their patch-wise appearance patterns aremore » similar. We first extract a set of key points in the new CT image. Then, for each key point, we adaptively construct a coupled dictionary from the training MRI-CT images, where each coupled element includes both appearance and deformation of the same image patch. After calculating the sparse coefficients in representing the patch appearance of each key point based on the constructed dictionary, we can predict the deformation for this point by applying the same sparse coefficients to the respective deformations in the dictionary. Results: This registration technique was validated with 10 prostate-cancer patients’ data and its performance was compared with the commonly used free-form-deformation-based registration. Several landmarks in both images were identified to evaluate the accuracy of our approach. Overall, the averaged target registration error of the intensity-based registration and the proposed method was 3.8±0.4 mm and 1.9±0.3 mm, respectively. Conclusion: We have developed a novel prostate MR-CT registration approach based on patch-deformation dictionary, demonstrated its clinical feasibility, and validated its accuracy. This technique will either reduce or compensate for the effect of patient-specific treatment variation measured during the course of radiotherapy, is therefore well-suited for a number of MRI-guided adaptive radiotherapy, and potentially enhance prostate radiotherapy treatment outcome.« less
An underwater turbulence degraded image restoration algorithm
NASA Astrophysics Data System (ADS)
Furhad, Md. Hasan; Tahtali, Murat; Lambert, Andrew
2017-09-01
Underwater turbulence occurs due to random fluctuations of temperature and salinity in the water. These fluctuations are responsible for variations in water density, refractive index and attenuation. These impose random geometric distortions, spatio-temporal varying blur, limited range visibility and limited contrast on the acquired images. There are some restoration techniques developed to address this problem, such as image registration based, lucky region based and centroid-based image restoration algorithms. Although these methods demonstrate better results in terms of removing turbulence, they require computationally intensive image registration, higher CPU load and memory allocations. Thus, in this paper, a simple patch based dictionary learning algorithm is proposed to restore the image by alleviating the costly image registration step. Dictionary learning is a machine learning technique which builds a dictionary of non-zero atoms derived from the sparse representation of an image or signal. The image is divided into several patches and the sharp patches are detected from them. Next, dictionary learning is performed on these patches to estimate the restored image. Finally, an image deconvolution algorithm is employed on the estimated restored image to remove noise that still exists.
Butts, Daniel A; Kanold, Patrick O; Shatz, Carla J
2007-01-01
Patterned spontaneous activity in the developing retina is necessary to drive synaptic refinement in the lateral geniculate nucleus (LGN). Using perforated patch recordings from neurons in LGN slices during the period of eye segregation, we examine how such burst-based activity can instruct this refinement. Retinogeniculate synapses have a novel learning rule that depends on the latencies between pre- and postsynaptic bursts on the order of one second: coincident bursts produce long-lasting synaptic enhancement, whereas non-overlapping bursts produce mild synaptic weakening. It is consistent with “Hebbian” development thought to exist at this synapse, and we demonstrate computationally that such a rule can robustly use retinal waves to drive eye segregation and retinotopic refinement. Thus, by measuring plasticity induced by natural activity patterns, synaptic learning rules can be linked directly to their larger role in instructing the patterning of neural connectivity. PMID:17341130
Retinovascular physiology and pathophysiology: new experimental approach/new insights
Puro, Donald G.
2012-01-01
An important challenge in visual neuroscience is understand the physiology and pathophysiology of the intra-retinal vasculature, whose function is required for ophthalmoception by humans and most other mammals. In the quest to learn more about this highly specialized portion of the circulatory system, a newly developed method for isolating vast microvascular complexes from the rodent retina has opened the way for using techniques such as patch-clamping, fluorescence imaging and time-lapse photography to elucidate the functional organization of a capillary network and its pre-capillary arteriole. For example, the ability to obtain dual perforated-patch recordings from well-defined sites within an isolated microvascular complex permitted the first characterization of the electrotonic architecture of a capillary/arteriole unit. This analysis revealed that this operational unit is not simply a homogenous synctium, but has a complex functional organization that is dynamically modulated by extracellular signals such as angiotensin II. Another recent discovery is that a capillary and its pre-capillary arteriole have distinct physiological differences; capillaries have an abundance of ATP-sensitive potassium (KATP) channels and a dearth of voltage-dependent calcium channels (VDCCs) while the converse is true for arterioles. In addition, voltage transmission between abluminal cells and the endothelium is more efficient in the capillaries. Thus, the capillary network is well-equipped to generate and transmit voltages, and the pre-capillary arteriole is well-adapted to transduce a capillary-generated voltage into a change in abluminal cell calcium and thereby, a vasomotor response. Use of microvessels isolated from the diabetic retina has led to new insights concerning retinal vascular pathophysiology. For example, soon after the onset of diabetes, the efficacy of voltage transmission through the endothelium is diminished; arteriolar VDCCs is inhibited, and there is increased vulnerability to purinergic vasotoxicity, which is a newly identified pathobiological mechanism. Other recent studies reveal that KATP channels not only have an essential physiological role in generating vasomotor responses, but their activation substantially boosts the lethality of hypoxia. Thus, the pathophysiology of the retinal microvasculature is closely linked with its physiology. PMID:22333041
[Precision of navigation-assisted surgery of the thoracic and lumbar spine].
Arand, M; Schempf, M; Hebold, D; Teller, S; Kinzl, L; Gebhard, F
2003-11-01
The goal of these studies was to evaluate the accuracy of in vivo and in vitro application of CT- and C-arm-based navigation at the thoracic and lumbar spine. With CT based navigation, 82 pedicle screws were consecutively inserted, 53 into the thoracic and 29 into the lumbar spine. Seven (13%) perforations were detected at the thoracic spine and two (7%) at the lumbar spine. Additionally, minor perforations below the thread depth were seen in six (11%) thoracic and in two (7%) lumbar instrumentation. With C-arm-based navigation, 74 screws were consecutively placed into 38 thoracic and 36 lumbar pedicles. Perforations were noted in ten (26%) thoracic and four (11%) lumbar implants. Minor perforations were observed in another nine (24%) thoracic and ten (28%) lumbar pedicles. The observer-independent and standardized in vitro study based on a transpedicular 3.2-mm drill hole aiming a 4-mm steel ball in a plastic bone model showed pedicle perforations of the drill canal only in thoracic vertebrae, 1 of 15 in CT-based and 3 of 15 in C-arm navigation. The quantitative calculation of the smallest distance between the central line through the drill canal and the center of the steel ball resulted in 1.4 mm (0.5-4.8 mm) for the CT-based navigation at the thoracic spine and in 1.8 mm (0.5-3 mm) at the lumbar spine. For the C-arm based navigation the distance was 2.6 mm (0.9-4.8 mm) for the thoracic spine and 2 mm (1.2-3 mm) for the lumbar spine. In our opinion, the clinical results of the comparative accuracy of CT- and C-arm-based navigation in the present study showed moderate advantages of the CT-based technique in the thoracic spine, whereas CT- and C-arm based navigation had comparable perforation rates at the lumbar pedicle. The results of the experimental study correlated with the clinical data.
Buccal patches of atenolol formulated using fenugreek (Trigonella foenum-graecum L.) seed mucilage.
Adhikari, Surya Narayan Ratha; Panda, Satyabrata
2017-01-01
The use of mucoadhesive natural polymers in designing mucoadhesive patch systems has received much attention. The study involved the development and evaluation of buccal patches of atenolol using fenugreek (Trigonella foenum-graecum L.) seed mucilage with hydroxylpropyl methyl cellulose (HPMC K4M) and a backing membrane (ethyl cellulose 5% w/v). These atenolol-releasing buccal patches were prepared using a solvent casting technique. The buccal patches prepared were evaluated for average weight, thickness, drug content, folding endurance and moisture content. Ex vivo mucoadhesive strength, force of adhesion and bonding strength were determined using porcine buccal mucosa. The mucosal permeation of atenolol through the porcine buccal mucosa was carried out using a Franz diffusion cell in phosphate buffer saline, pH 6.8. These buccal patches were also characterized by SEM and FTIR spectroscopy. The average weight, thickness, drug content, folding endurance and moisture content of these atenolol-releasing buccal patches were found satisfactory for all the patches. Amongst all, the F-4 buccal patch showed maximum mucoadhesive strength (31.12 ±1.86 g), force of adhesion (30.53 × 10-2 N) and bond strength (1748.89 N/m2). Ex vivo atenolol permeation from the buccal patches showed drug permeation across the excised porcine buccal mucosa over 12 h. The F-4 buccal patch showed maximum permeation flux (29.12 μg/cm2/h). The developed atenolol-releasing buccal patches can be beneficial over the conventional drug delivery systems to decrease the dosing frequency and enhance patient compliance.
2012-01-01
Background While progress has been made to develop automatic segmentation techniques for mitochondria, there remains a need for more accurate and robust techniques to delineate mitochondria in serial blockface scanning electron microscopic data. Previously developed texture based methods are limited for solving this problem because texture alone is often not sufficient to identify mitochondria. This paper presents a new three-step method, the Cytoseg process, for automated segmentation of mitochondria contained in 3D electron microscopic volumes generated through serial block face scanning electron microscopic imaging. The method consists of three steps. The first is a random forest patch classification step operating directly on 2D image patches. The second step consists of contour-pair classification. At the final step, we introduce a method to automatically seed a level set operation with output from previous steps. Results We report accuracy of the Cytoseg process on three types of tissue and compare it to a previous method based on Radon-Like Features. At step 1, we show that the patch classifier identifies mitochondria texture but creates many false positive pixels. At step 2, our contour processing step produces contours and then filters them with a second classification step, helping to improve overall accuracy. We show that our final level set operation, which is automatically seeded with output from previous steps, helps to smooth the results. Overall, our results show that use of contour pair classification and level set operations improve segmentation accuracy beyond patch classification alone. We show that the Cytoseg process performs well compared to another modern technique based on Radon-Like Features. Conclusions We demonstrated that texture based methods for mitochondria segmentation can be enhanced with multiple steps that form an image processing pipeline. While we used a random-forest based patch classifier to recognize texture, it would be possible to replace this with other texture identifiers, and we plan to explore this in future work. PMID:22321695
NASA Technical Reports Server (NTRS)
Jones, Kenneth M.; Biedron, Robert T.; Whitlock, Mark
1995-01-01
A computational study was performed to determine the predictive capability of a Reynolds averaged Navier-Stokes code (CFL3D) for two-dimensional and three-dimensional multielement high-lift systems. Three configurations were analyzed: a three-element airfoil, a wing with a full span flap and a wing with a partial span flap. In order to accurately model these complex geometries, two different multizonal structured grid techniques were employed. For the airfoil and full span wing configurations, a chimera or overset grid technique was used. The results of the airfoil analysis illustrated that although the absolute values of lift were somewhat in error, the code was able to predict reasonably well the variation with Reynolds number and flap position. The full span flap analysis demonstrated good agreement with experimental surface pressure data over the wing and flap. Multiblock patched grids were used to model the partial span flap wing. A modification to an existing patched- grid algorithm was required to analyze the configuration as modeled. Comparisons with experimental data were very good, indicating the applicability of the patched-grid technique to analyses of these complex geometries.
NASA Technical Reports Server (NTRS)
Ricci, A. J.; Rennie, K. J.; Correia, M. J.
1996-01-01
Hair cells were dissociated from the semicircular canal, utricle, lagena and saccule of white king pigeons. Type I hair cells were identified morphologically based on the ratios of neck width to cuticular plate width (NPR < 0.72) as well as neck width to cell body width (NBR < 0.64). The perforated patch variant of the whole-cell recording technique was used to measure electrical properties from type I hair cells. In voltage-clamp, the membrane properties of all identified type I cells were dominated by a predominantly outward potassium current, previously characterized in semicircular canal as IKI. Zero-current potential, activation, deactivation, slope conductance, pharmacologic and steady-state properties of the complex currents were not statistically different between type I hair cells of different vestibular end organs. The voltage dependence causes a significant proportion of this conductance to be active about the cell's zero-current potential. The first report of the whole-cell activation kinetics of the conductance is presented, showing a voltage dependence that could be best fit by an equation for a single exponential. Results presented here are the first data from pigeon dissociated type I hair cells from utricle, saccule and lagena suggesting that the basolateral conductances of a morphologically identified population of type I hair cells are conserved between functionally different vestibular end organs; the major conductance being a delayed rectifier characterized previously in semicircular canal hair cells as IKI.
Assessment on the methods of measuring the tyre-road contact patch stresses
NASA Astrophysics Data System (ADS)
Anghelache, G.; Moisescu, A.-R.; Buretea, D.
2017-08-01
The paper reviews established and modern methods for investigating tri-axial stress distributions in the tyre-road contact patch. The authors used three methods of measuring stress distributions: strain gauge method; force sensing technique; acceleration measurements. Four prototypes of instrumented pins transducers involving mentioned measuring methods were developed. Data acquisitions of the contact patch stresses distributions were performed using each transducer with instrumented pin. The results are analysed and compared, underlining the advantages and drawbacks of each method. The experimental results indicate that the three methods are valuable.
An Enhanced Vacuum Cure Technique for On-Aircraft Repair of Carbon-Bismaleimide Composites
NASA Astrophysics Data System (ADS)
Rider, Andrew N.; Baker, Alan A.; Wang, Chun H.; Smith, Graeme
2011-06-01
Carbon/bismaleimide (BMI) composite is increasingly employed in critical load carrying aircraft structures designed to operate at temperatures approaching 180°C. The high post-cure temperature (above 220°C) required to fully react the BMI resin, however, renders existing on-aircraft prepreg or wet layup repair methods invalid. This paper presents a new on-aircraft repair technique for carbon/BMI composites. The composite prepregs are first warm-staged to improve the ability to evacuate entrapped air. Then the patch is cured in the scarf cavity using the vacuum bag technique, followed by off-aircraft post-cure. The fully cured patch then can be bonded using a structural adhesive.
A Comparison of Retrievability: Celect versus Option Filter.
Ryu, Robert K; Desai, Kush; Karp, Jennifer; Gupta, Ramona; Evans, Alan Emerson; Rajeswaran, Shankar; Salem, Riad; Lewandowski, Robert J
2015-06-01
To compare the retrievability of 2 potentially retrievable inferior vena cava filter devices. A retrospective, institutional review board-approved study of Celect (Cook, Inc, Bloomington, Indiana) and Option (Rex Medical, Conshohocken, Pennsylvania) filters was conducted over a 33-month period at a single institution. Fluoroscopy time, significant filter tilt, use of adjunctive retrieval technique, and strut perforation in the inferior vena cava were recorded on retrieval. Fisher exact test and Mann-Whitney-Wilcoxon test were used for comparison. There were 99 Celect and 86 Option filters deployed. After an average of 2.09 months (range, 0.3-7.6 mo) and 1.94 months (range, 0.47-9.13 mo), respectively, 59% (n = 58) of patients with Celect filters and 74.7% (n = 65) of patients with Option filters presented for filter retrieval. Retrieval failure rates were 3.4% for Celect filters versus 7.7% for Option filters (P = .45). Median fluoroscopy retrieval times were 4.25 minutes for Celect filters versus 6 minutes for Option filters (P = .006). Adjunctive retrieval techniques were used in 5.4% of Celect filter retrievals versus 18.3% of Option filter retrievals (P = .045). The incidence of significant tilting was 8.9% for Celect filters versus 16.7% for Option filters (P = .27). The incidence of strut perforation was 43% for Celect filters versus 0% for Option filters (P < .0001). Retrieval rates for the Celect and Option filters were not significantly different. However, retrieval of the Option filter required a significantly increased amount of fluoroscopy time compared with the Celect filter, and there was a significantly greater usage of adjunctive retrieval techniques for the Option filter. The Celect filter had a significantly higher rate of strut perforation. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.
Network Patch Cables Demystified: A Super Activity for Computer Networking Technology
ERIC Educational Resources Information Center
Brown, Douglas L.
2004-01-01
This article de-mystifies network patch cable secrets so that people can connect their computers and transfer those pesky files--without screaming at the cables. It describes a network cabling activity that can offer students a great hands-on opportunity for working with the tools, techniques, and media used in computer networking. Since the…
NASA Technical Reports Server (NTRS)
Voigt, Kerstin
1992-01-01
We present MENDER, a knowledge based system that implements software design techniques that are specialized to automatically compile generate-and-patch problem solvers that satisfy global resource assignments problems. We provide empirical evidence of the superior performance of generate-and-patch over generate-and-test: even with constrained generation, for a global constraint in the domain of '2D-floorplanning'. For a second constraint in '2D-floorplanning' we show that even when it is possible to incorporate the constraint into a constrained generator, a generate-and-patch problem solver may satisfy the constraint more rapidly. We also briefly summarize how an extended version of our system applies to a constraint in the domain of 'multiprocessor scheduling'.
A Life-Threatening Mediastinal Hematoma After Central Venous Port System Implantation
Sarach, Janine; Zschokke, Irin; Melcher, Gian A.
2015-01-01
Patient: Female, 68 Final Diagnosis: Mediastinal hematoma Symptoms: Agitation • severe hemodynamic instability • severe respiratory distress Medication: — Clinical Procedure: Cardiopulmonary resuscitation • reintubation • thoracic drain Specialty: Surgery Objective: Diagnostic/therapeutic accidents Background: We report a case of surgical central venous port system implantation using Seldinger’s technique with a life-threatening mediastinal hematoma due to the perforation of the superior vena cava. Case Report: A 68-year-old woman was admitted to our institution for port implantation. Open access to the cephalic vein and 2 punctures of the right subclavian vein were unsuccessful. Finally, the port catheter could be placed into the superior vena cava using Seldinger’s technique. As blood aspiration via the port catheter was not possible, fluoroscopy was performed, revealing mediastinal contrast extravasation without contrasting the venous system. A new port system could be placed in the correct position without difficulties. After extubation, the patient presented with severe respiratory distress and required consecutive cardiopulmonary resuscitation and reintubation. The CT scan showed a significant hematoma in the lower neck and posterior mediastinum with tracheal compression. We assumed a perforation of the superior vena cava with the tip of the guidewire using Seldinger’s technique. Long-term intensive treatment with prolonged ventilation and tracheotomy was necessary. The port system had to be subsequently explanted due to infection. Conclusions: Mediastinal hematoma is a rare but life-threatening complication associated with central venous catheterization using Seldinger’s technique. Perforation occurs most often during central venous catheterization in critical care. Mediastinal hematoma is an example of a mechanical complication occurring after central venous catheterization, which has been described only a few times in the literature to date. This case highlights the importance of awareness of possible, rare, life-threatening complications during port implantation, mostly performed in multimorbid patients by surgeons in training. PMID:26703924
Py, Christophe; Martina, Marzia; Diaz-Quijada, Gerardo A.; Luk, Collin C.; Martinez, Dolores; Denhoff, Mike W.; Charrier, Anne; Comas, Tanya; Monette, Robert; Krantis, Anthony; Syed, Naweed I.; Mealing, Geoffrey A. R.
2011-01-01
All excitable cell functions rely upon ion channels that are embedded in their plasma membrane. Perturbations of ion channel structure or function result in pathologies ranging from cardiac dysfunction to neurodegenerative disorders. Consequently, to understand the functions of excitable cells and to remedy their pathophysiology, it is important to understand the ion channel functions under various experimental conditions – including exposure to novel drug targets. Glass pipette patch-clamp is the state of the art technique to monitor the intrinsic and synaptic properties of neurons. However, this technique is labor intensive and has low data throughput. Planar patch-clamp chips, integrated into automated systems, offer high throughputs but are limited to isolated cells from suspensions, thus limiting their use in modeling physiological function. These chips are therefore not most suitable for studies involving neuronal communication. Multielectrode arrays (MEAs), in contrast, have the ability to monitor network activity by measuring local field potentials from multiple extracellular sites, but specific ion channel activity is challenging to extract from these multiplexed signals. Here we describe a novel planar patch-clamp chip technology that enables the simultaneous high-resolution electrophysiological interrogation of individual neurons at multiple sites in synaptically connected neuronal networks, thereby combining the advantages of MEA and patch-clamp techniques. Each neuron can be probed through an aperture that connects to a dedicated subterranean microfluidic channel. Neurons growing in networks are aligned to the apertures by physisorbed or chemisorbed chemical cues. In this review, we describe the design and fabrication process of these chips, approaches to chemical patterning for cell placement, and present physiological data from cultured neuronal cells. PMID:22007170
Py, Christophe; Martina, Marzia; Diaz-Quijada, Gerardo A; Luk, Collin C; Martinez, Dolores; Denhoff, Mike W; Charrier, Anne; Comas, Tanya; Monette, Robert; Krantis, Anthony; Syed, Naweed I; Mealing, Geoffrey A R
2011-01-01
All excitable cell functions rely upon ion channels that are embedded in their plasma membrane. Perturbations of ion channel structure or function result in pathologies ranging from cardiac dysfunction to neurodegenerative disorders. Consequently, to understand the functions of excitable cells and to remedy their pathophysiology, it is important to understand the ion channel functions under various experimental conditions - including exposure to novel drug targets. Glass pipette patch-clamp is the state of the art technique to monitor the intrinsic and synaptic properties of neurons. However, this technique is labor intensive and has low data throughput. Planar patch-clamp chips, integrated into automated systems, offer high throughputs but are limited to isolated cells from suspensions, thus limiting their use in modeling physiological function. These chips are therefore not most suitable for studies involving neuronal communication. Multielectrode arrays (MEAs), in contrast, have the ability to monitor network activity by measuring local field potentials from multiple extracellular sites, but specific ion channel activity is challenging to extract from these multiplexed signals. Here we describe a novel planar patch-clamp chip technology that enables the simultaneous high-resolution electrophysiological interrogation of individual neurons at multiple sites in synaptically connected neuronal networks, thereby combining the advantages of MEA and patch-clamp techniques. Each neuron can be probed through an aperture that connects to a dedicated subterranean microfluidic channel. Neurons growing in networks are aligned to the apertures by physisorbed or chemisorbed chemical cues. In this review, we describe the design and fabrication process of these chips, approaches to chemical patterning for cell placement, and present physiological data from cultured neuronal cells.
Application of multidetector-row computed tomography in propeller flap planning.
Ono, Shimpei; Chung, Kevin C; Hayashi, Hiromitsu; Ogawa, Rei; Takami, Yoshihiro; Hyakusoku, Hiko
2011-02-01
The propeller flap is defined as (1) being island-shaped, (2) having an axis that includes the perforators, and (3) having the ability to be rotated around an axis. The advantage of the propeller flap is that it is a pedicle flap that can be applied to cover defects located at the distal ends of the extremities. The specific aims of the authors' study were (1) to evaluate the usefulness of multidetector-row computed tomography in the planning of propeller flaps and (2) to present a clinical case series of propeller flap reconstructions that were planned preoperatively using multidetector-row computed tomography. The authors retrospectively analyzed all cases between April of 2007 and April of 2010 at Nippon Medical School Hospital in Tokyo, where multidetector-row computed tomography was used preoperatively to plan surgical reconstructions using propeller flaps. Thirteen patients underwent 16 flaps using the propeller flap technique. The perforators were identified accurately by multidetector-row computed tomography preoperatively in all cases. This is the first report describing the application of multidetector-row computed tomography in the planning of propeller flaps. Multidetector-row computed tomography is superior to other imaging methods because it demonstrates more precisely the perforator's position and subcutaneous course using high-resolution three-dimensional images. By using multidetector-row computed tomography to preoperatively identify a flap's perforators, the surgeon can better plan the flap design to efficiently conduct the flap surgery.
Takahashi, Kei; Toyota, Taro
2015-01-01
The cytosol of amoeba cells controls the membrane deformation during their motion in vivo. To investigate such ability of the cytosol of amoeba cell, Dictyostelium discoideum (Dictyostelium), in vitro, we used lipids extracted from Dictyostelium and commercially available phospholipids, and prepared substrate-supported lipid membrane patches on the micrometer scale by spin coating. We found that the spin coater holder, which has pores (pore size = 3.1 mm) of negative pressure to hold the cover glass induced the concave surface of the cover glass. The membrane lipid patches were formed at each position in the vicinity of the holder pores and their sizes were in the range of 2.7 to 3.2 × 10(4) μm(2). After addition of the cytosol extracted from Dictyostelium to the lipid membrane patches, through time-lapse observation with a confocal laser scanning fluorescence microscope, we observed an autonomous buckling of the Dictyostelium lipid patches and localized behaviours of proteins found within. The current method serves as the novel technique for the preparation of film patches in which the positions of patches are controlled by the holder pores without fabricating, modifying, and arranging the chemical properties of the solution components of lipids. The findings imply that lipid-binding proteins in the cytosol were adsorbed and accumulated within the Dictyostelium lipid patches, inducing the transformation of the cell-sized patch.
Specification-based Error Recovery: Theory, Algorithms, and Usability
2013-02-01
transmuting the specification to an implementation at run-time and reducing the performance overhead. A suite of techniques and tools were designed...in the specification, thereby transmuting the specification to an implementation at run-time and reducing the perfor- mance overhead. A suite of
Integration of autopatching with automated pipette and cell detection in vitro
Wu (吴秋雨), Qiuyu; Kolb, Ilya; Callahan, Brendan M.; Su, Zhaolun; Stoy, William; Kodandaramaiah, Suhasa B.; Neve, Rachael; Zeng, Hongkui; Boyden, Edward S.; Forest, Craig R.
2016-01-01
Patch clamp is the main technique for measuring electrical properties of individual cells. Since its discovery in 1976 by Neher and Sakmann, patch clamp has been instrumental in broadening our understanding of the fundamental properties of ion channels and synapses in neurons. The conventional patch-clamp method requires manual, precise positioning of a glass micropipette against the cell membrane of a visually identified target neuron. Subsequently, a tight “gigaseal” connection between the pipette and the cell membrane is established, and suction is applied to establish the whole cell patch configuration to perform electrophysiological recordings. This procedure is repeated manually for each individual cell, making it labor intensive and time consuming. In this article we describe the development of a new automatic patch-clamp system for brain slices, which integrates all steps of the patch-clamp process: image acquisition through a microscope, computer vision-based identification of a patch pipette and fluorescently labeled neurons, micromanipulator control, and automated patching. We validated our system in brain slices from wild-type and transgenic mice expressing channelrhodopsin 2 under the Thy1 promoter (line 18) or injected with a herpes simplex virus-expressing archaerhodopsin, ArchT. Our computer vision-based algorithm makes the fluorescent cell detection and targeting user independent. Compared with manual patching, our system is superior in both success rate and average trial duration. It provides more reliable trial-to-trial control of the patching process and improves reproducibility of experiments. PMID:27385800
Posterior repair with perforated porcine dermal graft.
Taylor, G Bernard; Moore, Robert D; Miklos, John R; Mattox, T Fleming
2008-01-01
To compare postoperative vaginal incision separation and healing in patients undergoing posterior repair with perforated porcine dermal grafts with those that received grafts without perforations. Secondarily, the tensile properties of the perforated and non-perforated grafts were measured and compared. This was a non-randomized retrospective cohort analysis of women with stage II or greater rectoceles who underwent posterior repair with perforated and non-perforated porcine dermal grafts (Pelvicol(TM) CR Bard Covington, GA USA). The incidence of postoperative vaginal incision separation (dehiscence) was compared. A secondary analysis to assess graft tensile strength, suture pull out strength, and flexibility after perforation was performed using standard test method TM 0133 and ASTM bending and resistance protocols. Seventeen percent of patients (21/127) who received grafts without perforations developed vaginal incision dehiscence compared to 7% (5/71) of patients who received perforated grafts (p = 0.078). Four patients with vaginal incision dehiscence with non-perforated grafts required surgical revision to facilitate healing. Neither tensile strength or suture pull out strength were significantly different between perforated and non-perforated grafts (p = 0.81, p = 0.29, respectively). There was no difference in the flexibility of the two grafts (p = 0.20). Perforated porcine dermal grafts retain their tensile properties and are associated with fewer vaginal incision dehiscences.
The Effect of Different Shape and Perforated rHDPE in Concrete Structures on Flexural Strength
NASA Astrophysics Data System (ADS)
Yuhazri, MY; Hafiz, KM; Myia, YZA; Jia, CP; Sihombing, H.; Sapuan, SM; Badarulzaman, NA
2017-10-01
This research was carried out to develop a reinforcing structure from recycled HDPE plastic lubricant containers to be embedded in concrete structure. Different forms and shapes of recycled HDPE plastic are designed as reinforcement incorporate with cement. In this study, the reinforcing structure was prepared by washing, cutting, dimensioning and joining of the waste HDPE containers (direct technique without treatment on plastic surface). Then, the rHDPE reinforced concrete was produced by casting based on standard of procedure in civil engineering technique. Eight different shapes of rHDPE in concrete structure were used to determine the concrete’s ability in terms of flexural strength. Embedded round shape in solid and perforated of rHDPE in concrete system drastically improved flexural strength at 17.78 % and 13.79 %. The result would seem that the concrete with reinforcing rHDPE structure exhibits a more gradual or flexible properties than concrete beams without reinforcement that has the properties of fragile.
Ion channel drug discovery and research: the automated Nano-Patch-Clamp technology.
Brueggemann, A; George, M; Klau, M; Beckler, M; Steindl, J; Behrends, J C; Fertig, N
2004-01-01
Unlike the genomics revolution, which was largely enabled by a single technological advance (high throughput sequencing), rapid advancement in proteomics will require a broader effort to increase the throughput of a number of key tools for functional analysis of different types of proteins. In the case of ion channels -a class of (membrane) proteins of great physiological importance and potential as drug targets- the lack of adequate assay technologies is felt particularly strongly. The available, indirect, high throughput screening methods for ion channels clearly generate insufficient information. The best technology to study ion channel function and screen for compound interaction is the patch clamp technique, but patch clamping suffers from low throughput, which is not acceptable for drug screening. A first step towards a solution is presented here. The nano patch clamp technology, which is based on a planar, microstructured glass chip, enables automatic whole cell patch clamp measurements. The Port-a-Patch is an automated electrophysiology workstation, which uses planar patch clamp chips. This approach enables high quality and high content ion channel and compound evaluation on a one-cell-at-a-time basis. The presented automation of the patch process and its scalability to an array format are the prerequisites for any higher throughput electrophysiology instruments.
Design And Simulation Of Microstrip Antenna Of 2.4 GHz Using CST
NASA Astrophysics Data System (ADS)
Thakur, O. P.; Kushwaha, Alok K.
2011-12-01
This article describes the design, fabrication and testing of micro strip patch antennas operating at 2.4 GHz. Consideration is given on practical design technique, including substrate selection and antenna measurements. It is emphasised to the radiation properties of the antennas—the radiation pattern and polarization purity. A micro strip patch antenna consists of a very thin metallic patch placed a small fraction of a wavelength above a conducting ground-plane. The patch and ground-plane are separated by a dielectric. The patch conductor is normally copper and can assume any shape, but simple geometries generally are used, and this simplifies the analysis and performance prediction. The patches are usually photo etched on the dielectric substrate. The substrate is usually non-magnetic. The relative permittivity of the substrate is normally in the region between 1 and 4, which enhances the fringing fields that account for radiation, but higher values may be used in special circumstances. Due to its simple geometry, the half wave rectangular patch is the most commonly used micro strip antenna. It is characterized by its length L, width w and thickness h. The simplest method of feeding the patch is by a coplanar micro strip line, also photo etched on the substrate. Coaxial feeds are also widely used.
Temporal Characteristics and Energy Deposition of Pulsating Auroral Patches
NASA Technical Reports Server (NTRS)
Humberset, B. K.; Gjerloev, J. W.; Samara, M.; Michell, R. G.; Mann, I. R.
2016-01-01
We present a careful statistical analysis of pulsating aurora (PA) using all-sky green line (557.7 nm) images obtained at 3.3 Hz. Six well-defined individual PA patches are identified and extracted using a contouring technique. Quantitative parameters such as the patch duration (on-time and off-time), peak intensity, and integrated intensity are determined for each patch and each pulsation. The resulting characteristics serve as strict observational constraints that any of the many competing theories attempting to explain PA must predict. The purpose of this paper is to determine the characteristics of PA patches in order to provide better observational constraints on the suggested mechanisms. All aspects of the temporal behavior of the individual patches appear to be erratic. Historically, PA has been defined very loosely and we argue that the use of the term pulsating is inappropriate since our findings and other published results are not regularly periodic and thus a more appropriate term may be fluctuating aurora. Further, we find that the observational constraints do not fit well with the flow cyclotron maser theory, which in particular is suggested to create PA patches. There is no clear candidate of the suggested mechanisms and drivers to explain the observational constraints set by the PA patches in a satisfactory manner.
Phonon Avoided and Scalable Cascade Lasers (PASCAL)
2008-11-01
up We fully developed the mask-less nanolithography technique. The SEM micrographs show that highly uniform nanoholes and nanopillars array can be...by the technique and we produced a large area of high uniform nanoholes perforated in Al films, which is a big step towards making quantum dot...spheres on photoresist ’ • A. W A - " > EN • • • ^Ti—i Figure 14 - SEM images series showing nanoholes generated with
Izumi, Ken; Fujikawa, Masakazu; Tashima, Hiroki; Saito, Takuya; Sotsuka, Yohei; Tomita, Koichi; Hosokawa, Ko
2013-11-01
Recent advances in perforator flap surgical techniques have allowed for safe and reliable autologous tissue transfer with minimal donor-site morbidity. Between April 2012 and January 2013, we performed immediate breast reconstruction using free medial circumflex femoral artery perforator (MCFAP) flaps in 15 patients after breast-conserving surgery. The flaps were harvested from patients in the lithotomy position, while a second surgical team simultaneously conducted tumour resection. Of the 15 procedures performed, three flaps were dissected as true perforator flaps, while 12 flaps were dissected as muscle-sparing perforator flaps. The mean flap weight was 138.5 g (range, 77-230 g) and the mean pedicle length was 5.7 cm (range, 3.0-9.0 cm). Recipient vessels for anastomosis were serratus branches in 10 patients, internal mammary vessels in three patients and thoracodorsal vessels in two patients. The mean duration of surgery was 6.74 h (range, 5.65-9.45 h). There were no major complications requiring surgical intervention. Researchers observed partial flap necrosis, which manifested as small firm lesions in two patients, as well as local wound infection and dehiscence in one patient, which resolved spontaneously. There were no instances of donor-site seroma formation or lymphoedema in any of the patients. An objective assessment of postoperative photographs showed that cosmetic results were mostly satisfactory. Donor-site scars along the medial groin crease were inconspicuous and readily concealed by clothing. Given its reliable vascularity and minimal donor-site morbidity, the free MCFAP flap can be a good alternative for partial breast reconstruction after breast-conserving surgery. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Jiménez Fuertes, Montiel; Costa Navarro, David
2012-05-01
Large-bowel obstruction and perforation are still frequently occurring entities for the acute care surgeon. In these cases, Hartmann's procedure is the most commonly used surgical technique. However, recent papers demonstrate that colon resection and primary anastomosis (RPA) in the emergency setting is a safe and feasible procedure. We present our series of left colon resection and primary anastomosis procedures from Torrevieja Hospital (Alicante, Spain), performed without bowel irrigation or a diverting ileostomy. Thirty-two RPA procedures were performed in emergency settings for perforation or obstruction, or both, during an 18-month period. The following data were prospectively collected: age, gender, nationality, diagnoses, ASA score, body mass index (BMI), POSSUM score (Physiological and Operative Severity Score for the enumeration of Mortality and morbidity), and the score according to the Hinchey classification. Furthermore, duration of the operation, length of postoperative hospital stay, and mortality and morbidity data were recorded. Sixteen of these patients were diagnosed with acute diverticulitis, 14 patients with neoplasm (of which 9 cases had obstruction, 2 cases had perforation, and 3 cases had both), and foreign body perforation in the remaining 2 cases. The mean hospital stay was 7.8 (range, 4-10) days. The physiological POSSUM score was 24.4 (range, 15-39), and the surgical POSSUM score was 19.8 (range, 16-24). None of the patients died (0% mortality). Seven patients developed some kind of complication (21.9%), all of which were managed conservatively. The results of this study suggest that RPA for left colon obstruction and perforation in emergency settings can be safely performed in certain surgical conditions.
Laparoscopic correction of perforated peptic ulcer: first choice? A review of literature.
Bertleff, Mariëtta J O E; Lange, Johan F
2010-06-01
Perforated peptic ulcer (PPU), despite antiulcer medication and Helicobacter eradication, is still the most common indication for emergency gastric surgery associated with high morbidity and mortality. Outcome might be improved by performing this procedure laparoscopically, but there is no consensus on whether the benefits of laparoscopic closure of perforated peptic ulcer outweigh the disadvantages such as prolonged surgery time and greater expense. An electronic literature search was done by using PubMed and EMBASE databases. Relevant papers written between January 1989 and May 2009 were selected and scored according to Effective Public Health Practice Project guidelines. Data were extracted from 56 papers, as summarized in Tables 1-7. The overall conversion rate for laparoscopic correction of perforated peptic ulcer was 12.4%, with main reason for conversion being the diameter of perforation. Patients presenting with PPU were predominantly men (79%), with an average age of 48 years. One-third had a history of peptic ulcer disease, and one-fifth took nonsteroidal anti-inflammatory drugs (NSAIDs). Only 7% presented with shock at admission. There seems to be no consensus on the perfect setup for surgery and/or operating technique. In the laparoscopic groups, operating time was significant longer and incidence of recurrent leakage at the repair site was higher. Nonetheless there was significant less postoperative pain, lower morbidity, less mortality, and shorter hospital stay. There are good arguments that laparoscopic correction of PPU should be first treatment of choice. A Boey score of 3, age over 70 years, and symptoms persisting longer than 24 h are associated with higher morbidity and mortality and should be considered contraindications for laparoscopic intervention.
Laparoscopic correction of perforated peptic ulcer: first choice? A review of literature
Lange, Johan F.
2009-01-01
Background Perforated peptic ulcer (PPU), despite antiulcer medication and Helicobacter eradication, is still the most common indication for emergency gastric surgery associated with high morbidity and mortality. Outcome might be improved by performing this procedure laparoscopically, but there is no consensus on whether the benefits of laparoscopic closure of perforated peptic ulcer outweigh the disadvantages such as prolonged surgery time and greater expense. Methods An electronic literature search was done by using PubMed and EMBASE databases. Relevant papers written between January 1989 and May 2009 were selected and scored according to Effective Public Health Practice Project guidelines. Results Data were extracted from 56 papers, as summarized in Tables 1–7. The overall conversion rate for laparoscopic correction of perforated peptic ulcer was 12.4%, with main reason for conversion being the diameter of perforation. Patients presenting with PPU were predominantly men (79%), with an average age of 48 years. One-third had a history of peptic ulcer disease, and one-fifth took nonsteroidal anti-inflammatory drugs (NSAIDs). Only 7% presented with shock at admission. There seems to be no consensus on the perfect setup for surgery and/or operating technique. In the laparoscopic groups, operating time was significant longer and incidence of recurrent leakage at the repair site was higher. Nonetheless there was significant less postoperative pain, lower morbidity, less mortality, and shorter hospital stay. Conclusion There are good arguments that laparoscopic correction of PPU should be first treatment of choice. A Boey score of 3, age over 70 years, and symptoms persisting longer than 24 h are associated with higher morbidity and mortality and should be considered contraindications for laparoscopic intervention. PMID:20033725
Infrared moving small target detection based on saliency extraction and image sparse representation
NASA Astrophysics Data System (ADS)
Zhang, Xiaomin; Ren, Kan; Gao, Jin; Li, Chaowei; Gu, Guohua; Wan, Minjie
2016-10-01
Moving small target detection in infrared image is a crucial technique of infrared search and tracking system. This paper present a novel small target detection technique based on frequency-domain saliency extraction and image sparse representation. First, we exploit the features of Fourier spectrum image and magnitude spectrum of Fourier transform to make a rough extract of saliency regions and use a threshold segmentation system to classify the regions which look salient from the background, which gives us a binary image as result. Second, a new patch-image model and over-complete dictionary were introduced to the detection system, then the infrared small target detection was converted into a problem solving and optimization process of patch-image information reconstruction based on sparse representation. More specifically, the test image and binary image can be decomposed into some image patches follow certain rules. We select the target potential area according to the binary patch-image which contains salient region information, then exploit the over-complete infrared small target dictionary to reconstruct the test image blocks which may contain targets. The coefficients of target image patch satisfy sparse features. Finally, for image sequence, Euclidean distance was used to reduce false alarm ratio and increase the detection accuracy of moving small targets in infrared images due to the target position correlation between frames.
Dai, Linghui; He, Zhenming; Zhang, Xin; Hu, Xiaoqing; Yuan, Lan; Qiang, Ming; Zhu, Jingxian; Shao, Zhenxing; Zhou, Chunyan; Ao, Yingfang
2014-03-01
Cartilage repair still presents a challenge to clinicians and researchers alike. A more effective, simpler procedure that can produce hyaline-like cartilage is needed for articular cartilage repair. A technique combining microfracture with a biomaterial scaffold of perforated decalcified cortical-cancellous bone matrix (DCCBM; composed of cortical and cancellous parts) would create a 1-step procedure for hyaline-like cartilage repair. Controlled laboratory study. For the in vitro portion of this study, mesenchymal stem cells (MSCs) were isolated from bone marrow aspirates of New Zealand White rabbits. Scanning electron microscopy (SEM), confocal microscopy, and 1,9-dimethylmethylene blue assay were used to assess the attachment, proliferation, and cartilage matrix production of MSCs grown on a DCCBM scaffold. For the in vivo experiment, full-thickness defects were produced in the articular cartilage of the trochlear groove of 45 New Zealand White rabbits, and the rabbits were then assigned to 1 of 3 treatment groups: perforated DCCBM combined with microfracture (DCCBM+M group), perforated DCCBM alone (DCCBM group), and microfracture alone (M group). Five rabbits in each group were sacrificed at 6, 12, or 24 weeks after the operation, and the repair tissues were analyzed by histological examination, assessment of matrix staining, SEM, and nanoindentation of biomechanical properties. The DCCBM+M group showed hyaline-like articular cartilage repair, and the repair tissues appeared to have better matrix staining and revealed biomechanical properties close to those of the normal cartilage. Compared with the DCCBM+M group, there was unsatisfactory repair tissues with less matrix staining in the DCCBM group and no matrix staining in the M group, as well as poor integration with normal cartilage and poor biomechanical properties. The DCCBM scaffold is suitable for MSC growth and hyaline-like cartilage repair induction when combined with microfracture. Microfracture combined with a DCCBM scaffold is a promising method that can be performed and adopted into clinical treatment for articular cartilage injuries.
A comparison of injection pain and postoperative pain of two intraosseous anesthetic techniques.
Gallatin, Juliane; Nusstein, John; Reader, Al; Beck, Mike; Weaver, Joel
2003-01-01
The purpose of this prospective, randomized, blinded study was to compare injection pain and postoperative pain of an apical primary X-Tip intraosseous technique to a coronal primary Stabident intraosseous technique in mandibular first molars. Using a repeated-measures design, 41 subjects randomly received 2 primary intraosseous injections at 2 separate appointments. Using a site distal to the mandibular first molar for both injections, the subjects received 1.8 mL of 2% lidocaine with 1: 100,000 epinephrine administered with the X-Tip system using an apical location in alveolar mucosa or 1.8 mL of 2% lidocaine with 1: 100,000 epinephrine administered with the Stabident system using a coronal location in attached gingiva. The pain of infiltration, perforation, needle insertion, solution deposition, mock or actual guide sleeve removal and postoperative pain were recorded on a Heft-Parker visual analogue scale (VAS) scale for the 2 intraosseous systems. The results demonstrated that the apical primary X-Tip intraosseous technique was not statistically different (P > .05) from the coronal primary Stabident technique regarding pain ratings of infiltration, perforation, needle insertion, solution deposition, mock or actual guide sleeve removal and postoperative pain (at the time subjective anesthesia wore off). However, on postoperative days 1 through 3, significantly (P < .05) more males experienced postoperative pain with the X-Tip system than with the Stabident system.
Sala Almonacil, Vicente Andrés; Zaragozá García, José Miguel; Gómez Palonés, Francisco Julián; Plaza Martínez, Ángel; Ortíz Monzón, Eduardo
2012-08-01
Type IV Ehler-Danlos syndrome (EDS) patients are prone to life-threatening vascular complications. Surgical management of those complications is challenging owing to vessel wall fragility, which may result in hemorrhagic events and high mortality rates. Here we report a case of left common iliac aneurysm perforation of the ipsilateral iliac vein repaired using endovascular technique in a patient with EDS. A 54-year-old patient presented with heart failure symptoms that evolved over 1 week in association with left leg edema and steal syndrome due to a perforation of the left iliac vein caused by a left common iliac aneurysm. A thrombosed right common iliac aneurysm and several other visceral and peripheral aneurysms were discovered on computed tomographic scan at admission. An aortouniiliac stent graft was used to seal the fistula. After 18 months of follow-up, the patient remained asymptomatic. We suggest that endovascular therapy is useful to manage vascular complications in patients with EDS. Copyright © 2012 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.
Osteotomy in direct sinus lift. A comparative study of the rotary technique and ultrasound
Peñarrocha-Diago, Miguel; Sanchez-Recio, Cristina; Peñarrocha-Oltra, David; Romero-Millán, Javier
2012-01-01
Purpose: The present study investigates sinus membrane rupture in direct maxillary sinus lift with the rotary technique and with ultrasound, examining the survival of implants placed after sinus augmentation, and analyzing the bone gain obtained after the operation and 12 months after placement of the prosthetic restoration. Material and Methods: A retrospective study was made of 45 patients requiring maxillary sinus lift or augmentation for implant-prosthetic rehabilitation. Use was made of the hand piece and ostectomy drills for the rotary technique, and of specific tips for ultrasound. The implant success criteria were based on those developed by Buser. The bone gain obtained as a result of sinus lift was calculated from the postoperative panoramic X-rays. Results: A total of 57 direct elevations of the maxillary sinus were carried out: 32 with the rotary technique and 25 with ultrasound. Perforations of Schneider’s membrane with the rotary technique and ultrasound occurred in 7% and 1.7% of the cases, respectively, with membrane integrity being preserved in 91.2%. Of the 100 implants placed, 5 failed after one year of follow-up in the rotary technique group, while one implant failed in the ultrasound group. The rotary technique in turn afforded a bone gain of 5.9 mm, versus 6.7 mm with ultrasound. Conclusions: Perforations of the membrane sinusal in direct lift were more frequent with the rotary technique (7%) than with ultrasound (1.7%). Implant survival and bone gain were both greater when ultrasound was used. Key words:Bone sectioning, maxillary sinus augmentation, piezosurgery. PMID:22143735
Kundnani, Vishal; Dutta, Shumayou; Patel, Ankit; Mehta, Gaurav; Singh, Mahendra
2018-01-01
Study Design Prospective cohort study. Purpose To compare intraoperative parameters, radiation exposure, and pedicle screw perforation rate in navigation-guided versus non-navigated fluoroscopy-assisted minimal invasive transforaminal lumbar interbody fusion (MIS TLIF). Overview of Literature The poor reliability of fluoroscopy-guided instrumentation and growing concerns about radiation exposure have led to the development of navigation-guided instrumentation techniques in MIS TLIF. The literature evaluating the efficacy of navigation-guided MIS TLIF is scant. Methods Eighty-seven patients underwent navigation- or fluoroscopy-guided MIS TLIF for symptomatic lumbar/lumbosacral spondylolisthesis. Demographics, intraoperative parameters (surgical time, blood loss), and radiation exposure (sec/mGy/Gy.cm2 noted from C-arm for comparison only) were recorded. Computed tomography was performed in patients in the navigation and non-navigation groups at postoperative 12 months and reviewed by an independent observer to assess the accuracy of screw placement, perforation incidence, location, grade (Mirza), and critical versus non-critical neurological implications. Results Twenty-seven patients (male/female, 11/16; L4–L5/L5–S1, 9/18) were operated with navigation-guided MIS TLIF, whereas 60 (male/female, 25/35; L4–L5/L5–S1, 26/34) with conventional fluoroscopy-guided MIS TILF. The use of navigation resulted in reduced fluoroscopy usage (dose area product, 0.47 Gy.cm2 versus 2.93 Gy.cm2), radiation exposure (1.68 mGy versus 10.97 mGy), and fluoroscopy time (46.5 seconds versus 119.08 seconds), with p-values of <0.001. Furthermore, 96.29% (104/108) of pedicle screws in the navigation group were accurately placed (grade 0) (4 breaches, all grade I) compared with 91.67% (220/240) in the non-navigation group (20 breaches, 16 grade I+4 grade II; p=0.114). None of the breaches resulted in a corresponding neurological deficit or required revision. Conclusions Navigation guidance in MIS TLIF reduced radiation exposure, but the perforation status was not statistically different than that for the fluoroscopy-based technique. Thus, navigation in nondeformity cases is useful for significantly reducing the radiation exposure, but its ability to reduce pedicle screw perforation in nondeformity cases remains to be proven. PMID:29713413
Frequency-specific hearing outcomes in pediatric type I tympanoplasty.
Kent, David T; Kitsko, Dennis J; Wine, Todd; Chi, David H
2014-02-01
Middle ear disease is the primary cause of hearing loss in children and has a significant impact on language development and academic performance. Multiple prognostic factors have previously been examined, but there is little published data regarding frequency-specific hearing outcomes. To examine the relationship between type I tympanoplasty in a pediatric population and frequency-specific hearing changes, as well as the relationship between several prognostic factors and graft retention. Retrospective medical chart review (February 2006 to October 2011) of 492 consecutive pediatric otolaryngology patients undergoing type I tympanoplasty for tympanic membrane (TM) perforation of any etiology at a tertiary-care pediatric otolaryngology practice. Type I tympanoplasty. Preoperative and postoperative audiometric data were collected for patients undergoing successful TM repair. It was hypothesized before data collection that conductive hearing would improve at all frequencies with no significant change in sensorineural hearing. Data collected included air conduction at 250 to 8000 Hz, speech reception thresholds, bone conduction at 500 to 4000 Hz, and air-bone gap at 500 to 4000 Hz. Demographic data obtained included sex, age, size, mechanism, location of perforation, and operative repair technique. Of 492 patients, 320 were excluded; results were thus examined for 172 patients. Surgery was successful for 73.8% of patients. Perforation size was significantly associated with repair success (mean [SD] surgical success rate of 38.6% [15.3%] vs surgical failure rate of 31.4% [15.0%]; P < .01); however, mean (SD) age (9.02 [3.89] years [surgical success] vs 8.52 [3.43] years [surgical failure]; P > .05) and repair technique (medial [73.08%] vs lateral [76.47%] graft success; P > .99) were not. Air conduction significantly improved from 250 to 2000 Hz (P < .001), did not significantly improve at 4000 Hz (P = .08), and there was a nonsignificant decline at 8000 Hz (P = .12). Speech reception threshold significantly improved (20 vs 15 dB; P < .001). This large review found an association of TM perforation size with surgical success and an improvement in speech reception threshold, air conduction at 250 to 2000 Hz, air-bone gap at 500 to 2000 Hz, and worsening bone conduction at 4000 Hz. Patients with high-frequency hearing loss due to TM perforation should not anticipate significant recovery from type I tympanoplasty. Hearing loss at higher frequencies may require postoperative hearing rehabilitation.
Rumstadt, Bernhard; Schilling, Dieter
2008-01-01
Perforation during colonoscopy is a rare but severe complication. The aim of this study was to assess the time management and laparoscopic therapy of this complication and to evaluate patient outcomes. A retrospective analysis was done on 15 patients operated for a perforation from colonoscopy between January 2000 and December 2006. Three perforations occurred during diagnostic and 12 perforations during interventional colonoscopy. Two perforations occurred as transmural thermal injury to the colon wall. Peritonitis was found in 4 cases and significantly correlated with the mean time between perforation and operation. Twelve perforations were oversewn laparoscopically and 3 perforations were oversewn by laparotomy. After laparoscopic treatment, hospital stay was significantly shorter than after laparotomy. One patient had a postoperative wound infection, mortality was 0%. Laparoscopic oversewing is a safe and effective method in the treatment of perforation from colonoscopy. Optimizing the time range between perforation and laparoscopic therapy results in a better outcome for the patients.
A new technique for the closure of the lens capsule by laser welding.
Pini, Roberto; Rossi, Francesca; Menabuoni, Luca; Lenzetti, Ivo; Yoo, Sonia; Parel, Jean-Marie
2008-01-01
A new method is presented for the closure of the lens capsule based on laser welding of suitably prepared patches of anterior capsular tissue. Experiments were performed in freshly enucleated porcine eyes. The patches were previously stained with a solution of indocyanine green in sterile water and then welded on the recipient capsule by means of diode laser radiation at 810 nm. The welded tissue revealed mechanical properties comparable to those of healthy tissue. This technique is proposed to repair capsular breaks and to provide the closure of the capsulorhexis in lens refilling procedures.
Quasi-optical grids with thin rectangular patch/aperture elements
NASA Technical Reports Server (NTRS)
Wu, Te-Kao
1993-01-01
Theoretical analysis is presented for an efficient and accurate performance evaluation of quasi-optical grids comprised of thin rectangular patch/aperture elements with/without a dielectric substrate/superstrate. The convergence rate of this efficient technique is improved by an order of magnitude with the approximate edge conditions incorporated in the basis functions of the integral equation solution. Also presented are the interesting applications of this efficient analytical technique to the design and performance evaluation of the coupling grids and beam splitters in the optical systems as well as thermal protection sunshields used in the communication systems of satellites and spacecrafts.
Glove perforation rate in open lung surgery.
Hollaus, P H; Lax, F; Janakiev, D; Wurnig, P N; Pridun, N S
1999-04-01
In open lung surgery the surgical access is encircled by the ribs, which should result in a high glove perforation rate compared with other surgical specialities. Prospectively the surgeon, first and second assistant and the scrub nurse wore double standard latex gloves during 100 thoracotomies. Parameters recorded were: procedure performed, number of perforations, localization of perforation, the seniority of the surgeon, manoeuvre performed at the moment of perforation, immediate cause of perforation, operation time, performance of rib resection during thoracotomy and time of occurrence of the first three perforations. One thousand, six hundred and seventy-three gloves (902 outer, 771 inner) were tested. In 78 operations perforations occurred. There were 150 outer glove perforations (8.9%, 0-8, mean 1.23), 19 inner glove perforations (1.13%, 0-2, mean 0.19). Cutaneous blood exposure was prevented in 78% of all operations and in 87% of all perforations. The perforation rate for the surgeon, the scrub nurse, the first and the second assistant were 61.2, 40.4, 9.7 and 3.1% of all operations, respectively. Rib resection and a duration of more than 2 h resulted in a significant rise of glove perforation rate (P<0.05). The personal experience of the surgeon and the type of operation did not correlate with glove perforation. The immediate cause leading to perforation was named in only 17 cases (13.7%) and comprised contact with bone (seven), a needle stitch (seven) and a production flaw (three). Leaks were localized mostly on the first finger (18%),second finger, (39%) palm and dorsum of the hand (16%). The average occurrence of all first perforations was 38.7 min (range 3-190) after the beginning of surgery, the second after 63.2 min (range 10-195). Fifty-four first perforations (50.5%) were found during the first 30 min of the operation. The reported perforation rate of 78% lies in the highest range of reported perforation rates in different surgical specialities. Double gloving effectively prevented cutaneous blood exposure and thus should become a routine for the thoracic surgeon to prevent transmission of infectious diseases from the patient to the surgeon.
Wang, Ji-ping; Fan, Jin-cai; Chai, Jia-ke
2009-12-01
To study the effect of the technique of synchronously perforating and transplanting hair follicular-units in the treatment of cicatricial alopecia after burn. One hundred and sixty-six patients with 217 bald scar areas after burn were treated with above-mentioned technique from January 2002 to April 2008. Scalp strips, with conforming the necessity for grafting, were harvested from the occipital or temporal region. A series of follicular-units, each composing 1 - 3 hairs, were dissected from the strips under microscope or magnifying glass. Size-matching micro-slots were made in the scarred recipient area with 16 - 20 G needles to accept the grafts. The prepared follicular-unit was synchronously implanted into the bottom of the micro-slot as the needle being withdrawn. Patients who were not satisfactory with the density of hairs after I stage surgery underwent II stage surgery a half year later. Ten recipient areas with clear boundary in 10 patients were optionally chosen to observe the density of follicular-units and hair amount with naked eyes after I stage surgery. Survived transplanted hairs in above-mentioned 10 areas were counted to calculate hair survival rate at follow-up. Patients' postoperative satisfaction ratings were surveyed with questionnaire. In one half of the patients, treatment was finished after I stage surgery, the other one half received 2 stages of surgery. The follicular-unit density reached 15 - 25 grafts/cm(2) with 40 - 70 hairs/cm(2) after I stage surgery. All patients were followed up for over 8 months. Grafted hairs grew well in a natural way. 96.5% mean hair survival rate was observed in the 10 recipient areas. From patients who received only I stage surgery, 61 patients (73.5%) were very satisfactory and 22 patients (26.5%) satisfactory with the results. From the other half of patients, 76 patients (91.6%) were very satisfactory and 7 patients (8.4%) satisfactory with the results. The technique of perforating and transplanting follicular-unit hair synchronously is safe and effective with less surgery-induced injury and less bleeding. Hairs transplanted on cicatricial alopecia area with this technique grow well with high survival rate.
Portable Holographic Interferometry Testing System: Application to crack patching quality control
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heslehurst, R.B.; Baird, J.P.; Williamson, H.M.
Over recent years the repair of metallic structures has been improved through the use of patches fabricated from composite materials and adhesively bonded to the damaged area. This technology is termed crack patching, and has been successfully and extensively used by the RAAF and the USAF. However, application of the technology to civilian registered aircraft has had limited success due to the apparent lack of suitable quality assurance testing methods and the airworthiness regulators concern overpatch adhesion integrity. Holographic interferometry has previously shown the advantages of detecting out-of-plane deformations of the order of the wavelength of light (1{mu}). Evidence willmore » be presented that holography is able to detect changes in load path due to debonds and weakened adhesion in an adhesively bonded patch. A Portable Holographic Interferometry Testing System (PHITS) which overcomes the vibration isolation problem associated with conventional holography techniques has been developed. The application of PHITS to crack patching technology now provides a suitable method to verify the integrity of bonded patches in-situ.« less
Mohan, Anita T; Zhu, Lin; Sur, Yoo Joon; Morsy, Mohamed; Michalak, Gregory J; Lachman, Nirusha; Rammos, Charalambos K; Saint-Cyr, Michel
2017-04-01
This study aimed to delineate and compare the hot spots and three-dimensional vascular territories of dominant profunda artery perforators in the posterior thigh region, and modifications in flap design are discussed. Twenty-nine posterior thigh flaps were raised in fresh cadaveric specimens, and profunda artery perforators were documented. Dominant perforators were injected with iodinated contrast to assess perforasomes using computed tomographic angiography. Analysis with three-dimensional rendering and volume calculations of perfusion patterns was performed. In total, 316 perforators were mapped and 33 perforators were injected for analysis. The hot spot for dominant perforators was the proximal medial quadrant, 5 to 10 cm from the inferior gluteal crease, with two smaller hot spots in the upper lateral and distal posterior midline. Although 69 percent were musculocutaneous, distal perforators were predominantly septocutaneous in the posterior midline, 5 to 8 cm from the popliteal crease. Proximal perforators were classified into first (most proximal) and second perforators, and their median perforasome was 233 and 286.4 cm, respectively (p = 0.86). There were no significant differences between proximal and distal perforators in perforasome surface areas, percentage areas perfused, and perforasome volumes. Large linking vessel networks were attributed to a broader perforasome and greater overlap between adjacent or distal perforators. Dominant linking vessels and recurrent flow through the subdermal plexus contribute to the robust vascular supply of profunda artery perforator flaps. Posterior thigh region perforator hot spots and their perfusion characteristics can inform the potential limits, orientation, and modifications of flap or skin paddle designs.
Stacchi, Claudio; Robiony, Massimo; Jones, Jason Motta; Lombardi, Teresa; Verardi, Simone
2018-05-26
We read with great interest the article recently published by Dr. Lajolo et al, in which the authors compared conventional implant drills and piezoelectric technique during apical cortical plate perforation. Precisely, the aim of this study was to evaluate temperature variations occurring during implant site preparation at the apical cortical plate level of a porcine rib ex vivo model, by using the two aforementioned devices and different pressure loads. This article is protected by copyright. All rights reserved. © 2018 American Academy of Periodontology.
NASA Astrophysics Data System (ADS)
Li, Guoxin; Tang, Xiaoning; Zhang, Xiaoxiao; Qian, Y. J.; Kong, Deyi
2017-11-01
Flexible micro-perforated panel has unique advantages in noise reduction due to its good flexibility compared with traditional rigid micro-perforated panel. In this paper, flexible micro-perforated panel was prepared by computer numerical control (CNC) milling machine. Three kinds of plastics including polyvinylchloride (PVC), polyethylene terephthalate (PET), and polyimide (PI) were taken as the matrix materials to prepare flexible micro-perforated panel. It has been found that flexible micro-perforated panel made of PET possessing good porosity and proper density, elastic modulus and poisson ratio exhibited the best acoustic absorption properties. The effects of various structural parameters including perforation diameter, perforation ratio, thickness and air gap have also been investigated, which would be helpful to the optimization of acoustic absorption properties.
Modern treatment of oesophageal strictures.
Eastman, M C; Sali, A
1980-02-09
The results of 185 dilatations of oesophageal strictures with the rigid oesophagoscope are reported. The complication rate was 6%, which included five perforations (2.7%), and one death. The new technique of Eder-Puestow wire-guided dilatation was used in 20 cases without complication. These results, together with other reported experience of Eder-Puestow dilatation, suggest that this technique is superior to that of rigid dilatation on the grounds both of safety and of cost.
Danker, Timm; Braun, Franziska; Silbernagl, Nikole; Guenther, Elke
2016-03-01
Manual patch clamp, the gold standard of electrophysiology, represents a powerful and versatile toolbox to stimulate, modulate, and record ion channel activity from membrane fragments and whole cells. The electrophysiological readout can be combined with fluorescent or optogenetic methods and allows for ultrafast solution exchanges using specialized microfluidic tools. A hallmark of manual patch clamp is the intentional selection of individual cells for recording, often an essential prerequisite to generate meaningful data. So far, available automation solutions rely on random cell usage in the closed environment of a chip and thus sacrifice much of this versatility by design. To parallelize and automate the traditional patch clamp technique while perpetuating the full versatility of the method, we developed an approach to automation, which is based on active cell handling and targeted electrode placement rather than on random processes. This is achieved through an automated pipette positioning system, which guides the tips of recording pipettes with micrometer precision to a microfluidic cell handling device. Using a patch pipette array mounted on a conventional micromanipulator, our automated patch clamp process mimics the original manual patch clamp as closely as possible, yet achieving a configuration where recordings are obtained from many patch electrodes in parallel. In addition, our implementation is extensible by design to allow the easy integration of specialized equipment such as ultrafast compound application tools. The resulting system offers fully automated patch clamp on purposely selected cells and combines high-quality gigaseal recordings with solution switching in the millisecond timescale.
The three-dimensional simulation analysis of dynamic response on perforated strings
NASA Astrophysics Data System (ADS)
Li, M. F.; Liu, H. F.; Dou, Y. H.; Cao, L. H.; Liu, Y. X.
2018-06-01
It analyzes the dynamic response and stresses of perforating tubular string to detonating impact load in oil-gas well in ANSYS, obtains the response of vibration displacement, velocity and acceleration of perforating tubularstring caused by detonating impact load, finds the influence of the length and wall thickness of perforating tubular string to working stresses. The result shows that:when the detonating impact load exerts the perforating tubular string with compressive and tensile axial force alternatively;the vibration displacement, velocity and acceleration of perfora-ting tubular string change periodically at same cycle;the closer to the perforating gun, the larger the amplitude of vi-bration velocity and acceleration;the closer to the packer the smaller the vibration displacement, the larger the work-ing equivalent stress of perforating tubular string;the longer or the thicker the perforating tubular string, the smaller the working equivalent stress and the higher the strength safety. Therefore, it uses the damping tube between packer and perforating gun as well as thick walled tubing to increase the strength safety of perforating tubular string.
Research on the Perforating Algorithm Based on STL Files
NASA Astrophysics Data System (ADS)
Yuchuan, Han; Xianfeng, Zhu; Yunrui, Bai; Zhiwen, Wu
2018-04-01
In the process of making medical personalized external fixation brace, the 3D data file should be perforated to increase the air permeability and reduce the weight. In this paper, a perforating algorithm for 3D STL file is proposed, which can perforate holes, hollow characters and engrave decorative patterns on STL files. The perforating process is composed of three steps. Firstly, make the imaginary space surface intersect with the STL model, and reconstruct triangles at the intersection. Secondly, delete the triangular facets inside the space surface and make a hole on the STL model. Thirdly, triangulate the inner surface of the hole, and thus realize the perforating. Choose the simple space equations such as cylindrical and rectangular prism equations as perforating equations can perforate round holes and rectangular holes. Through the combination of different holes, lettering, perforating decorative patterns and other perforated results can be accomplished. At last, an external fixation brace and an individual pen container were perforated holes using the algorithm, and the expected results were reached, which proved the algorithm is feasible.
Li, C; Bhatt, P P; Johnston, T P
1998-10-01
We have assessed the bioadhesive properties of several different mucoadhesive buccal patches. The patches consisted of custom coformulations of silicone polymers and Carbopol 974P. The contact angle of water was measured for each of the test formulations, using an ophthalmic shadow scope. The corresponding work of adhesion between the water and the patches (W1), and between the patches and freshly-excised rabbit buccal mucosa (W2) was then calculated, using a modification of Dupre's equation. The bioadhesive strength between the patches and excised rabbit buccal mucosa was also assessed. The results of the contact-angle measurements indicated that the contact angle decreased with an increase in the amount of Carbopol in the formulation. Additionally, the calculated values of both W1 and W2 increased with an increase in the amount of Carbopol in the buccal-patch formulations. A correlation (r not equal to 0.9808) was found between the measured contact angle and the calculated values for W2. The direct measurement of the force required to separate a buccal patch from excised rabbit buccal mucosa with the INSTRON demonstrated that the adhesive strength increased with an increase in the amount of Carbopol. This preliminary study has shown that the measurement of contact angles alone may provide a useful technique for estimating the work of adhesion, and may serve as a convenient and rapid screening procedure to identify potential mucoadhesive buccal-patch formulations.
Extension theorems for homogenization on lattice structures
NASA Technical Reports Server (NTRS)
Miller, Robert E.
1992-01-01
When applying homogenization techniques to problems involving lattice structures, it is necessary to extend certain functions defined on a perforated domain to a simply connected domain. This paper provides general extension operators which preserve bounds on derivatives of order l. Only the special case of honeycomb structures is considered.
Development of Modal Test Techniques for Validation of a Solar Sail Design
NASA Technical Reports Server (NTRS)
Gaspar, James L.; Mann, Troy; Behun, Vaughn; Wilkie, W. Keats; Pappa, Richard
2004-01-01
This paper focuses on the development of modal test techniques for validation of a solar sail gossamer space structure design. The major focus is on validating and comparing the capabilities of various excitation techniques for modal testing solar sail components. One triangular shaped quadrant of a solar sail membrane was tested in a 1 Torr vacuum environment using various excitation techniques including, magnetic excitation, and surface-bonded piezoelectric patch actuators. Results from modal tests performed on the sail using piezoelectric patches at different positions are discussed. The excitation methods were evaluated for their applicability to in-vacuum ground testing and to the development of on orbit flight test techniques. The solar sail membrane was tested in the horizontal configuration at various tension levels to assess the variation in frequency with tension in a vacuum environment. A segment of a solar sail mast prototype was also tested in ambient atmospheric conditions using various excitation techniques, and these methods are also assessed for their ground test capabilities and on-orbit flight testing.
Chen, Qin; Yim, Peter D.; Yuan, Nina; Johnson, Juliette; Cook, James M.; Smith, Steve; Ionescu-Zanetti, Cristian; Wang, Zhi-Jian; Arnold, Leggy A.
2012-01-01
Abstract Ensemble recording and microfluidic perfusion are recently introduced techniques aimed at removing the laborious nature and low recording success rates of manual patch clamp. Here, we present assay characteristics for these features integrated into one automated electrophysiology platform as applied to the study of GABAA channels. A variety of cell types and methods of GABAA channel expression were successfully studied (defined as IGABA>500 pA), including stably transfected human embryonic kidney (HEK) cells expressing α1β3γ2 GABAA channels, frozen ready-to-assay (RTA) HEK cells expressing α1β3γ2 or α3β3γ2 GABAA channels, transiently transfected HEK293T cells expressing α1β3γ2 GABAA channels, and immortalized cultures of human airway smooth muscle cells endogenously expressing GABAA channels. Current measurements were successfully studied in multiple cell types with multiple modes of channel expression in response to several classic GABAA channel agonists, antagonists, and allosteric modulators. We obtained success rates above 95% for transiently or stably transfected HEK cells and frozen RTA HEK cells expressing GABAA channels. Tissue-derived immortalized cultures of airway smooth muscle cells exhibited a slightly lower recording success rate of 75% using automated patch, which was much higher than the 5% success rate using manual patch clamp technique by the same research group. Responses to agonists, antagonists, and allosteric modulators compared well to previously reported manual patch results. The data demonstrate that both the biophysics and pharmacologic characterization of GABAA channels in a wide variety of cell formats can be performed using this automated patch clamp system. PMID:22574655
Bonadio, William; Bruno, Santina; Attaway, David; Dharmar, Logesh; Tam, Derek; Homel, Peter
2017-06-01
Pediatric appendicitis is a common, potentially serious condition. Determining perforation status is crucial to planning effective management. Determine the efficacy of serum total bilirubin concentration [STBC] in distinguishing perforation status in children with appendicitis. Retrospective review of 257 cases of appendicitis who received abdominal CT scan and measurement of STBC. There were 109 with perforation vs 148 without perforation. Although elevated STBC was significantly more common in those with [36%] vs without perforation [22%], the mean difference in elevated values between groups [0.1mg/dL] was clinically insignificant. Higher degrees of hyperbilirubinemia [>2mg/dL] were rarely encountered [5%]. Predictive values for elevated STBC in distinguishing perforation outcome were imprecise [sensitivity 38.5%, specificity 78.4%, PPV 56.8%, NPV 63.4%]. ROC curve analysis of multiple clinical and other laboratory factors for predicting perforation status was unenhanced by adding the STBC variable. Specific analysis of those with perforated appendicitis and percutaneously-drained intra-abdominal abscess which was culture-positive for Escherichia coli showed an identical rate of STBC elevation compared to all with perforation. The routine measurement of STBC does not accurately distinguish perforation status in children with appendicitis, nor discern infecting organism in those with perforation and intra-abdominal abscess. Copyright © 2017 Elsevier Inc. All rights reserved.
Chan, K Y; Singh, V A; Oun, B H; To, B H Se
2006-12-01
Glove perforation during surgery has always been a matter of concern as it increases the infection rate and the risk of transmission of blood borne diseases. To determine the common causes, the site and the awareness of glove perforations in orthopaedic surgery, a prospective study was conducted to assess the rate of glove perforation during 130 consecutive orthopaedic operations. All gloves worn by the surgical team were assessed after the surgery using the water-loading test. A total of 1452 gloves were tested, and the rate of perforation was 3.58%. Most of these perforations (61.5%) were unnoticed. The main surgeons had the most perforations (76.9%), followed by first assistants (13.5%) and second assistants (9.6%). Most perforations occurred at the non-dominant hand. The commonest site of perforation was the index finger followed by the thumb. Shearing force with instruments accounted for 45% of the noticed perforations. Majority of these occurred during nailing procedures (33%) and internal fixation without the use of wires (19%). Our rate of glove perforation is similar to other series. Most of them went unnoticed and were mainly due to shearing injuries rather than perforation by sharps. Therefore, there is an increased risk of contamination and break in asepsis during surgery.
Malysz, John; Afeli, Serge A. Y.; Provence, Aaron
2013-01-01
Mechanisms underlying ethanol (EtOH)-induced detrusor smooth muscle (DSM) relaxation and increased urinary bladder capacity remain unknown. We investigated whether the large conductance Ca2+-activated K+ (BK) channels or L-type voltage-dependent Ca2+ channels (VDCCs), major regulators of DSM excitability and contractility, are targets for EtOH by patch-clamp electrophysiology (conventional and perforated whole cell and excised patch single channel) and isometric tension recordings using guinea pig DSM cells and isolated tissue strips, respectively. EtOH at 0.3% vol/vol (∼50 mM) enhanced whole cell BK currents at +30 mV and above, determined by the selective BK channel blocker paxilline. In excised patches recorded at +40 mV and ∼300 nM intracellular Ca2+ concentration ([Ca2+]), EtOH (0.1–0.3%) affected single BK channels (mean conductance ∼210 pS and blocked by paxilline) by increasing the open channel probability, number of open channel events, and open dwell-time constants. The amplitude of single BK channel currents and unitary conductance were not altered by EtOH. Conversely, at ∼10 μM but not ∼2 μM intracellular [Ca2+], EtOH (0.3%) decreased the single BK channel activity. EtOH (0.3%) affected transient BK currents (TBKCs) by either increasing frequency or decreasing amplitude, depending on the basal level of TBKC frequency. In isolated DSM strips, EtOH (0.1–1%) reduced the amplitude and muscle force of spontaneous phasic contractions. The EtOH-induced DSM relaxation, except at 1%, was attenuated by paxilline. EtOH (1%) inhibited L-type VDCC currents in DSM cells. In summary, we reveal the involvement of BK channels and L-type VDCCs in mediating EtOH-induced urinary bladder relaxation accommodating alcohol-induced diuresis. PMID:24153429
Qi, Song-tao; Huang, Chuan-ping; Lu, Yun-tao; Pan, Jun; Fan, Jun
2007-05-01
To study the microanatomy of the perforating arteries in the superior space of the internal carotid artery visualized through a pterional approach. Twelve (24 sides) perfused cadaver heads were dissected via the pterional approach, and the perforating arteries in the superior space of the internal carotid artery were studied under microscope. The diameter, course and distribution in the anterior perforated substance of the perforating arteries were recorded. All the perforating arteries exposed lied on the side of the brain tissue. The carotid bifurcation on 8 sides had perforating arteries, and 11 sides showed medial lenticulostriate artery of the middle cerebral arteries, with short course and overlapped with another perforating arteries upon entry into the anterior perforated substance. On 4 sides, the medial lenticulostriate artery coincided with the perforating arteries in A1. All 24 sides showed middle lenticulostriate artery and lateral lenticulostriate artery of the middle cerebral arteries. Most of the lenticulostriate arteries originated from the anterior segment of the bifurcation of the middle cerebral arteries. The earlier bifurcation occurred in M1 of the middle cerebral arteries, the more perforating arteries originated. On 22 sides, the anterior cerebral arteries had perforating arteries with many branches, and fewer perforating arteries in a main artery were associated with greater diameter of them. The superior space of the internal carotid artery allows a space for operation, and in some cases, part of the medial leticulostriate arteries and A1 perforating arteries can be severed to obtain larger space for the operation.
2008-10-01
AD); Aeolos, a distributed intrusion detection and event correlation infrastructure; STAND, a training-set sanitization technique applicable to ADs...UU 18. NUMBER OF PAGES 25 19a. NAME OF RESPONSIBLE PERSON Frank H. Born a. REPORT U b. ABSTRACT U c . THIS PAGE U 19b. TELEPHONE...Summary of findings 2 (a) Automatic Patch Generation 2 (b) Better Patch Management 2 ( c ) Artificial Diversity 3 (d) Distributed Anomaly Detection 3
Rosenbaum, Daniel G; Askin, Gulce; Beneck, Debra M; Kovanlikaya, Arzu
2017-10-01
The role of magnetic resonance imaging (MRI) in pediatric appendicitis is increasing; MRI findings predictive of appendiceal perforation have not been specifically evaluated. To assess the performance of MRI in differentiating perforated from non-perforated appendicitis. A retrospective review of pediatric patients undergoing contrast-enhanced MRI and subsequent appendectomy was performed, with surgicopathological confirmation of perforation. Appendiceal diameter and the following 10 MRI findings were assessed: appendiceal restricted diffusion, wall defect, appendicolith, periappendiceal free fluid, remote free fluid, restricted diffusion within free fluid, abscess, peritoneal enhancement, ileocecal wall thickening and ileus. Two-sample t-test and chi-square tests were used to analyze continuous and discrete data, respectively. Sensitivity and specificity for individual MRI findings were calculated and optimal thresholds for measures of accuracy were selected. Seventy-seven patients (mean age: 12.2 years) with appendicitis were included, of whom 22 had perforation. The perforated group had a larger mean appendiceal diameter and mean number of MRI findings than the non-perforated group (12.3 mm vs. 8.6 mm; 5.0 vs. 2.0, respectively). Abscess, wall defect and restricted diffusion within free fluid had the greatest specificity for perforation (1.00, 1.00 and 0.96, respectively) but low sensitivity (0.36, 0.25 and 0.32, respectively). The receiver operator characteristic curve for total number of MRI findings had an area under the curve of 0.92, with an optimal threshold of 3.5. A threshold of any 4 findings had the best ability to accurately discriminate between perforated and non-perforated cases, with a sensitivity of 82% and specificity of 85%. Contrast-enhanced MRI can differentiate perforated from non-perforated appendicitis. The presence of multiple findings increases diagnostic accuracy, with a threshold of any four findings optimally discriminating between perforated and non-perforated cases. These results may help guide management decisions as MRI assumes a greater role in the work-up of pediatric appendicitis.
Robotic Automation of In Vivo Two-Photon Targeted Whole-Cell Patch-Clamp Electrophysiology.
Annecchino, Luca A; Morris, Alexander R; Copeland, Caroline S; Agabi, Oshiorenoya E; Chadderton, Paul; Schultz, Simon R
2017-08-30
Whole-cell patch-clamp electrophysiological recording is a powerful technique for studying cellular function. While in vivo patch-clamp recording has recently benefited from automation, it is normally performed "blind," meaning that throughput for sampling some genetically or morphologically defined cell types is unacceptably low. One solution to this problem is to use two-photon microscopy to target fluorescently labeled neurons. Combining this with robotic automation is difficult, however, as micropipette penetration induces tissue deformation, moving target cells from their initial location. Here we describe a platform for automated two-photon targeted patch-clamp recording, which solves this problem by making use of a closed loop visual servo algorithm. Our system keeps the target cell in focus while iteratively adjusting the pipette approach trajectory to compensate for tissue motion. We demonstrate platform validation with patch-clamp recordings from a variety of cells in the mouse neocortex and cerebellum. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Wearable Inset-Fed FR4 Microstrip Patch Antenna Design
NASA Astrophysics Data System (ADS)
Zaini, S. R. Mohd; Rani, K. N. Abdul
2018-03-01
This project proposes the design of a wireless body area network (WBAN) microstrip patch antenna covered by the jeans fabric as the outer layer operating at the center frequency, fc of 2.40 GHz. Precisely, the microstrip patch antenna with the inset-fed edge technique is designed and simulated systematically by using the Keysight Advanced Design System (ADS) software where the FR4 board with the dielectric constant, ɛr of 4.70, dissipation factor or loss tangent, tan δ of 0.02 and height, h of 1.60 mm is the chosen dielectric substrate. The wearable microstrip patch antenna design is then fabricated using the FR4 printed circuit board (PCB) material, hidden inside the jeans fabric, and attached to clothing, such as a jacket accordingly. Simulation and fabrication measurement results show that the designed microstrip patch antenna characteristics can be applied significantly within the industrial, scientific, and medical (ISM) radio band, which is at fc = 2.40 GHz.
Shijun, Xu; Junsheng, Mu; Jianqun, Zhang; Ping, Bo
2016-03-01
Identifying a suitable polymeric biomaterial for myocardial patch repair following myocardial infarction, cerebral infarction, and cartilage injury is essential. This study aimed to investigate the effect of the novel polymer material, poly3-hydroxybutyrate-co-3-hydroxyhexanoate, on the adhesion, proliferation, and differentiation of mouse-induced pluripotent stem cells in vitro. Mouse-induced pluripotent stem cells were isolated, expanded, and cultured on either two-dimensional or three-dimensional poly3-hydroxybutyrate-co-3-hydroxyhexanoate films (membranes were perforated to imitate three-dimensional space). Following attachment onto the films, mouse-induced pluripotent stem cell morphology was visualized using scanning electron microscopy. Cell vitality was detected using the Cell Counting Kit-8 assay and cell proliferation was observed using fluorescent 4',6-diamidino-2-phenylindole (DAPI) staining. Mouse-induced pluripotent stem cells were induced into cardiomyocytes by differentiation medium containing vitamin C. A control group in the absence of an inducer was included. Mouse-induced pluripotent stem cell survival and differentiation were observed using immunofluorescence and flow cytometry, respectively. Mouse-induced pluripotent stem cells growth, proliferation, and differentiation were observed on both two-dimensional and three-dimensional poly3-hydroxybutyrate-co-3-hydroxyhexanoate films. Vitamin C markedly improved the efficiency of mouse-induced pluripotent stem cells differentiation into cardiomyocytes on poly3-hydroxybutyrate-co-3-hydroxyhexanoate films. Three-dimensional culture was better at promoting mouse-induced pluripotent stem cell proliferation and differentiation compared with two-dimensional culture. © The Author(s) 2016.
Haksever, Mehmet; Akduman, Davut; Solmaz, Fevzi; Gündoğdu, Ercan
2015-04-01
The aim of this study is to compare the inlay butterfly transcanal cartilage tympanoplasty with the conventional underlay tympanoplasty. Operation time, pre- and postoperative hearing levels, successful closure rate of tympanic membrane (take rate) and long-term re-perforation in dry perforated chronic otitis media were evaluated. The study design consists of case series with a chart review. The study settings are tertiary referral center. Of the 72 patients (age range 14-57 years) with dry perforated chronic otitis media, 29 patients underwent inlay butterfly transcanal cartilage tympanoplasty (group 1) and 43 patients underwent conventional underlay tympanoplasty without mastoidectomy (group 2) between January 2010 and June 2012. The outcome measures were the duration of surgery, "take rate" at the 30th postoperative day and the audiometric results at the 45th postoperative day. Long-term re-perforation was evaluated at least postoperative 1 year. The graft take rate was 96.5 % in group 1 and 90.7 % in group 2 at the 30th postoperative day (p > 0.05). Mean air-bone gap was improved from 18.8 ± 8.09 to 11.9 ± 7.12 dB in group 1 and from 21.9 ± 7.32 to 11.6 ± 8.43 dB in group 2. The improvement of air-bone gap in both groups was statistically significant (p < 0.05) but the improvement between the groups was not statistically significant (p > 0.05). The average duration of the surgery was 29.9 ± 5.38 min for inlay tympanoplasty group and 58.9 ± 12.1 min for underlay tympanoplasty group (p < 0.05). Two patients in group 2 had re-perforations after an initial take of the graft in 1-year follow-up period. Inlay butterfly transcanal cartilage tympanoplasty is a good choice in selected cases. Although this technique has the similar take rate and audiological results with conventional underlay tympanoplasty, it is a time-saving procedure.
Björk, Ann-Kristin; Bruze, Magnus; Engfeldt, Malin; Nielsen, Christel; Svedman, Cecilia
2017-01-01
In the contact dermatitis literature, it is regularly stated that the patch test reactivity on various areas of the back differs, which might have a large impact on the reproducibility of patch testing. To investigate the reproducibility of patch testing on the upper back with regard to the left as opposed to the right side, and the medial as opposed to the lateral part of the upper back. The reproducibility over time and with regard to the reactivity pattern was also investigated. Thirty-one subjects with contact allergy to the metals gold (n = 19) or nickel (n = 12) were patch tested with serial dilutions, in triplicate applications, on different locations on the upper back. The Friedman test was used for statistical calculations. No significant differences in the reactivity of the back were found. In all gold-allergic patients and 11 of 12 nickel-allergic patients, the allergy could be reproduced with regard to previous patch testing, but the degree of reactivity differed. When a high level of standardization of the patch test technique with the same test system was used, there were no differences in patch test reactions and sites of application on the upper back. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Fs-laser-induced Ca2+ concentration change during membrane perforation for cell transfection.
Baumgart, J; Bintig, W; Ngezahayo, A; Lubatschowski, H; Heisterkamp, A
2010-02-01
Fs-laser based opto-perforation is a gentle method for gene transfer into sensitive cells such as stem cells or primary cells. The high selectivity and the low damage to the cell lead to a high efficiency of transfection. However, there are side effects which induce stress to the cell due to the exchange of intra- and extracellular media as well as the disintegration of the structure of biomolecules resulting from the laser exposure. Moreover, the mechanisms of the optical transfection are still unclear. In this paper, we present our study on calcium (Ca(2+)) homeostasis during cell surgery, especially during laser induced membrane perforation. We show that the manipulation of cells can induce an increase in the cytosolic Ca(2+) concentration. This increase was not observed if the manipulation of the cells was performed in absence of the extracellular calcium indicating the importance of the Ca(2+) uptake. We found, that the uptake of extracellular Ca(2+) strongly depends on the repetition rate and the irradiation time of the laser pulses. The exposure for several seconds to kHz pulses even induces Ca(2+) induced Ca(2+) release. Dependent on the location of perforation, probably in the vicinity of an intracellular Ca(2+) stock, an instantaneous intracellular Ca(2+) release can be induced. Since Ca(2+) could be involved in negative side effect by cell surgery, we propose an application of the optoperforation technique in nominal Ca(2+)-free external solution.
Psoas tunnel perforation—an unreported complication of hip arthroscopy
Degen, Ryan M.; O’Sullivan, Eilish; Sink, Ernest L.; Kelly, Bryan T.
2015-01-01
The utilization of hip arthroscopy is rapidly increasing due to improved arthroscopic techniques and training, better recognition of pathology responsible for non-arthritic hip pain and an increasing desire for minimally invasive procedures. With increasing rates of arthroscopy, associated complications are also being recognized. We present a series of six patients who experienced psoas tunnel perforation during anchor insertion from the distal anterolateral portal during labral repair. All patients underwent prior hip arthroscopy and labral repair and presented with persistent symptoms at least partly attributable to magnetic resonance imaging (MRI)-documented psoas tunnel perforation. Their clinical records, operative notes and intra-operative photographs were reviewed. All patients presented with persistent pain, both with an anterior impingement test and resisted hip flexion. MRI imaging demonstrated medial cortical perforation with anchors visualized in the psoas tunnel, adjacent to the iliopsoas muscle. Four patients have undergone revision hip arthroscopy, whereas two have undergone periacetabular osteotomies. All patients had prominent anchors in the psoas tunnel removed at the time of surgery, with varying degrees of concomitant pathology appropriately treated during the revision procedure. Care must be utilized during medial anchor placement to avoid psoas tunnel perforation. Although this complication alone was not the sole cause for revision in each case, it may have contributed to their poor outcome and should be avoided in future cases. This can be accomplished by using a smaller anchor, inserting the anchor from the mid-anterior portal and checking the drill hole with a nitinol wire prior to anchor insertion. PMID:27011849
A Novel Perforator Flap Training Model Using a Chicken Leg.
Cifuentes, Ignacio J; Yañez, Ricardo A; Salisbury, Maria C; Rodriguez, José R; Varas, Julian E; Dagnino, Bruno L
2016-04-01
Living animal models are frequently used for perforator flap dissection training, but no ex vivo models have been described. The aim of this study is to present a novel nonliving model for perforator flap training based on a constant perforator in the chicken leg. A total of 15 chicken legs were used in this study. Anatomical dissection of the perforator was performed after its identification using ink injection, and in four of these specimens a perforator-based flap was raised. The anatomical dissection revealed a constant intramuscular perforator with a median length of 5.7 cm. Median proximal and distal vessel diameters were 0.93 and 0.4 mm, respectively. The median dissection time was 77.5 minutes. This study introduces a novel, affordable, and reproducible model for the intramuscular dissection of a perforator-based flap using an ex vivo animal model. Its consistent perforator and appropriate-sized vessels make it useful for training.
Singh, Kumkum; Singh, Amit; Vidyarthi, Shivaji H; Jindal, Satyaprakash; Thounaojam, Chandra Kumar
2013-01-01
A liver abscess formation is a rare complication of a gallbladder perforation, with a cholecystohepatic communication. Niemeier, in 1934, classified free gallbladder perforations and generalised biliary peritonitis as an acute or a Type I gallbladder perforation, a pericholecystic abscess and localised peritonitis as a subacute or a Type II gallbladder perforation, and cholecystoenteric fistulas as chronic or Type III gallbladder perforations. We are describing a 50–year–old male patient who presented with right upper quadrant pain and was found to have an intrahepatic perforation of the gallbladder. Our patient had a Type II perforation. We have discussed the diagnostic work-up and the management of this rare entity. Due to the high mortality that can be caused by a delay in making the correct diagnosis, a gallbladder perforation represents a special diagnostic and surgical challenge. PMID:24179927
Off-pump repair of a post-infarct ventricular septal defect: the 'Hamburger procedure'
Barker, Thomas A; Ng, Alexander; Morgan, Ian S
2006-01-01
We report a novel off-pump technique for the surgical closure of post-infarct ventricular septal defects (VSDs). The case report describes the peri-operative management of a 76 year old lady who underwent the 'Hamburger procedure' for closure of her apical VSD. Refractory cardiogenic shock meant that traditional patch repairs requiring cardiopulmonary bypass would be poorly tolerated. We show that echocardiography guided off-pump posterior-anterior septal plication is a safe, effective method for closing post-infarct VSDs in unstable patients. More experience is required to ascertain whether this technique will become an accepted alternative to patch repairs. PMID:16722552
Fire detection behind a wall by using microwave techniques
NASA Astrophysics Data System (ADS)
Alkurt, Fatih Özkan; Baǧmancı, Mehmet; Karaaslan, Muharrem; Bakır, Mehmet; Altıntaş, Olcay; Karadaǧ, Faruk; Akgöl, Oǧuzhan; Ünal, Emin
2018-02-01
In this work, detection of the fire location behind a wall by using microwave techniques is illustrated. According to Planck's Law, Blackbody emits electromagnetic radiation in the microwave region of the electromagnetic spectrum. This emitted waves penetrates all materials except that metals. These radiated waves can be detected by using directional and high gain antennas. The proposed antenna consists of a simple microstrip patch antenna and a 2×2 microstrip patch antenna array. FIT based simulation results show that 2×2 array antenna can absorb emitted power from a fire source which is located behind a wall. This contribution can be inspirational for further works.
Resolution enhancement of wide-field interferometric microscopy by coupled deep autoencoders.
Işil, Çağatay; Yorulmaz, Mustafa; Solmaz, Berkan; Turhan, Adil Burak; Yurdakul, Celalettin; Ünlü, Selim; Ozbay, Ekmel; Koç, Aykut
2018-04-01
Wide-field interferometric microscopy is a highly sensitive, label-free, and low-cost biosensing imaging technique capable of visualizing individual biological nanoparticles such as viral pathogens and exosomes. However, further resolution enhancement is necessary to increase detection and classification accuracy of subdiffraction-limited nanoparticles. In this study, we propose a deep-learning approach, based on coupled deep autoencoders, to improve resolution of images of L-shaped nanostructures. During training, our method utilizes microscope image patches and their corresponding manual truth image patches in order to learn the transformation between them. Following training, the designed network reconstructs denoised and resolution-enhanced image patches for unseen input.
Effects of finite ground plane on the radiation characteristics of a circular patch antenna
NASA Astrophysics Data System (ADS)
Bhattacharyya, Arun K.
1990-02-01
An analytical technique to determine the effects of finite ground plane on the radiation characteristics of a microstrip antenna is presented. The induced currents on the ground plane and on the upper surface of the patch are determined from the discontinuity of the near field produced by the equivalent magnetic current source on the physical aperture of the patch. The radiated fields contributed by the induced current on the ground plane and the equivalent sources on the physical aperture yield the radiation pattern of the antenna. Radiation patterns of the circular patch with finite ground plane size are computed and compared with the experimental data, and the agreement is found to be good. The radiation pattern, directive gain, and input impedance are found to vary widely with the ground plane size.
Patch models and their applications to multivehicle command and control.
Rao, Venkatesh G; D'Andrea, Raffaello
2007-06-01
We introduce patch models, a computational modeling formalism for multivehicle combat domains, based on spatiotemporal abstraction methods developed in the computer science community. The framework yields models that are expressive enough to accommodate nontrivial controlled vehicle dynamics while being within the representational capabilities of common artificial intelligence techniques used in the construction of autonomous systems. The framework allows several key design requirements of next-generation network-centric command and control systems, such as maintenance of shared situation awareness, to be achieved. Major features include support for multiple situation models at each decision node and rapid mission plan adaptation. We describe the formal specification of patch models and our prototype implementation, i.e., Patchworks. The capabilities of patch models are validated through a combat mission simulation in Patchworks, which involves two defending teams protecting a camp from an enemy attacking team.
No patch technique for complete atrioventricular canal repair.
Aramendi, José Ignacio; Rodriguez, Miguel Angel; Luis, Teresa; Voces, Roberto
2006-08-01
We describe our initial experience with a new technique, consisting in direct closure of the ventricular septal defect component of the AV canal, by directly attaching the common bridging leaflets to the crest of the ventricular septum with interrupted sutures. After closure of the cleft, the ostium primum defect was closed with a running suture suturing the border of the septum primum to the newly created AV valve annulus. Three patients were operated upon. There was no mortality. Mean ischemic time was 39 min and mean pump time 77 min. All patients remained in sinus rhythm. At follow-up only trivial or mild mitral regurgitation was observed. This new technique permits the repair of complete AV canal without the need for any patch. It is fast, simple and reproducible.
Zang, Mengqing; Yu, Shengji; Xu, Libin; Zhao, Zhenguo; Zhu, Shan; Ding, Qiang; Liu, Yuanbo
2015-06-01
Trunk defects following soft tissue sarcoma resection are usually managed by myocutaneous flaps or free flaps. However, harvesting muscle will cause functional morbidities and some trunk regions lack reliable recipient vessels. The intercostal arteries give off multiple perforators, which distribute widely over the trunk and can supply various pedicle flaps. Our purpose is to use various intercostal artery perforator propeller flaps for trunk oncologic reconstruction. Between November 2013 and July 2014, nine intercostal artery perforator propeller flaps were performed in seven patients to reconstruct the defects following sarcoma resection in different regions of the trunk, including the back, lumbar, chest, and abdomen. Two perforators from intercostal arteries were identified for each flap using Doppler ultrasound probe adjacent to the defect. The perforator with visible pulsation was chosen as the pedicle vessel. An elliptical flap was raised and rotated in a propeller fashion to repair the defects. There were one dorsal intercostal artery perforator flap, four dorsolateral intercostal artery perforator flaps, three lateral intercostal artery perforator flaps, and one anterior intercostal artery perforator flap. The mean skin paddle dimension was 9.38 cm in width (range 6-14 cm) and 21.22 cm in length (range 13-28 cm). All intercostal artery perforator flaps survived completely, except for marginal necrosis in one flap harvested close to the previous flap donor site. The intercostal artery perforator propeller flap provides various and valuable options in our reconstructive armamentarium for trunk oncologic reconstruction. To our knowledge, this is the first case series of using intercostal artery perforator propeller flaps for trunk oncologic reconstruction and clinical application of dorsolateral intercostal artery perforator flaps. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Park, Sun-June; Lee, Kyeong-Tae; Jeon, Byung-Joon; Woo, Kyong-Je
2018-04-01
Pedicled perforator flaps (PPFs) have been widely used to treat pressure sores in the gluteal region. Selection of a reliable perforator is crucial for successful surgical treatment of pressure sores using PPFs. In this study, we evaluate the role of magnetic resonance imaging (MRI) in planning PPF reconstruction of pressure sores in the gluteal region. A retrospective chart review was performed in patients who had undergone these PPF reconstructions and who had received preoperative MRI. Preoperatively, the extent of infection and necrotic tissue was evaluated using MRI, and a reliable perforator was identified, considering the perforator location in relation to the defect, perforator size, and perforator courses. Intraoperatively, the targeted perforator was marked on the skin at the locations measured on the MRI images, and the marked location was confirmed using intraoperative handheld Doppler. Superior gluteal artery, inferior gluteal artery, or parasacral perforators were used for the PPFs. Surgical outcomes were evaluated. A total of 12 PPFs were performed in 12 patients. Superior gluteal artery perforator flaps were performed in 7 patients, inferior gluteal artery perforator flaps were performed in 3 patients, and parasacral perforator flaps were performed in 2 patients. We could identify a reliable perforator on MRI, and it was found at the predicted locations in all cases. There was only one case of partial flap necrosis. There was no recurrence of the pressure sores during the mean follow-up period of 6.7 months (range = 3-15 months). In selected patients with gluteal pressure sores, MRI is a suitable means for not only providing information about disease extent and comorbidities but also for evaluating perforators for PPF reconstructions.
Paramuscular perforators in DIEAP flap for breast reconstruction.
Pons, Gemma; Masia, Jaume; Sanchez-Porro, Lídia; Larrañaga, Jose; Clavero, Juan Angel
2014-12-01
One of the main steps in perforator flap surgery is to identify the dominant perforator. Using multidetector row computed tomography (MDCT) for the preoperative planning of deep inferior epigastric artery perforator (DIEAP) flap surgery, we identified a perforator with a large caliber, an excellent location in the middle abdominal region, and a totally extramuscular trajectory in a significant number of patients. We describe the frequency of this perforator and determine its characteristics. We conducted a retrospective study of 482 patients who underwent 526 DIEAP flaps for breast reconstruction from October 2003 to October 2011. Mean age at surgery was 51.3 years old. A preoperative MDCT of abdominal vascularization was performed in all patients. MDCT identified a dominant perforator with a paramuscular course in 12.4% of abdominal walls. In all cases, it was located in the midline and emerged directly from the deep inferior epigastric system. Its mean caliber was 1.9 mm. The flap was harvested based on this perforator in all these patients, and mean harvest time was 51 minutes. The characteristics of this perforator made dissection easier and reduced morbidity at the donor site. There were no flap losses and the only complications were minor. We located a paramuscular perforator in 12.4% of patients undergoing breast reconstruction with abdominal perforator flaps. Its morphological features and extramuscular course make it the perforator of choice in DIEAP flap surgery.
[Localization of perforators in the lower leg by digital antomy imaging methods].
Wei, Peng; Ma, Liang-Liang; Fang, Ye-Dong; Xia, Wei-Zhi; Ding, Mao-Chao; Mei, Jin
2012-03-01
To offer both the accurate three-dimensional anatomical information and algorithmic morphology of perforators in the lower leg for perforator flaps design. The cadaver was injected with a modified lead oxide-gelatin mixture. Radiography was first performed and the images were analyzed using the software Photoshop and Scion Image. Then spiral CT scan was also performed and 3-dimensional images were reconstructed with MIMICS 10.01 software. There are (27 +/- 4) perforators whose outer diameter > or = 0.5 mm ( average, 0.8 +/- 0.2 mm). The average pedicle length within the superficial fascia is (37.3 +/- 18.6) mm. The average supplied area of each perforator is (49.5 +/- 25.5) cm2. The three-dimensional model displayed accurate morphology structure and three-dimensional distribution of the perforator-to- perforator and perforator-to-source artery. The 3D reconstruction model can clearly show the geometric, local details and three-dimensional distribution. It is a considerable method for the study of morphological characteristics of the individual perforators in human calf and preoperative planning of the perforator flap.
Triple flap technique for vulvar reconstruction.
Mercut, R; Sinna, R; Vaucher, R; Giroux, P A; Assaf, N; Lari, A; Dast, S
2018-04-09
Perineal defects are encountered ever more frequently, in the treatment of vulvar cancers or abdominoperineal resection. The surgical treatment of vulvar cancer leads to significant skin defect. The aim of the reconstruction is not to provide volume but rather to resurface perineum. We propose a new solution to cover the extensive skin defect remaining after excision. We report 3 patients who underwent large excision for vulvar cancer, with lymph node dissection. For reconstruction, we performed 3 advancement flaps. Two V-Y flaps cantered on the infra-gluteal folds and based on pudendal perforator arteries were used to cover the postero-lateral parts of the defect. The third advancement flap from the superior aspect of the defect was a Y-V Mons pubis flap. The defects were successfully covered by the 3 flap technique. The first patient suffered a non-union that slowly healed by secondary intention. For the other cases, we used the same technique, but applied negative pressure wound therapy on the sutures, with excellent results. The 3 flap technique is a simple and reliable method and the donor site morbidity is minimal. It can be realised without changing the position of the patient after tumour excision, and does not require delicate perforator dissection. This surgical option can be easily applied, allowing better management of these cases. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Dual patch voltage clamp study of low membrane resistance astrocytes in situ.
Ma, Baofeng; Xu, Guangjin; Wang, Wei; Enyeart, John J; Zhou, Min
2014-03-17
Whole-cell patch clamp recording has been successfully used in identifying the voltage-dependent gating and conductance properties of ion channels in a variety of cells. However, this powerful technique is of limited value in studying low membrane resistance cells, such as astrocytes in situ, because of the inability to control or accurately measure the real amplitude of command voltages. To facilitate the study of ionic conductances of astrocytes, we have developed a dual patch recording method which permits membrane current and membrane potential to be simultaneously recorded from astrocytes in spite of their extraordinarily low membrane resistance. The utility of this technique is demonstrated by measuring the voltage-dependent activation of the inwardly rectifying K+ current abundantly expressed in astrocytes and multiple ionic events associated with astrocytic GABAA receptor activation. This protocol can be performed routinely in the study of astrocytes. This method will be valuable for identifying and characterizing the individual ion channels that orchestrate the electrical activity of low membrane resistance cells.
Small Molecules for Early Endosome-Specific Patch Clamping.
Chen, Cheng-Chang; Butz, Elisabeth S; Chao, Yu-Kai; Grishchuk, Yulia; Becker, Lars; Heller, Stefan; Slaugenhaupt, Susan A; Biel, Martin; Wahl-Schott, Christian; Grimm, Christian
2017-07-20
To resolve the subcellular distribution of endolysosomal ion channels, we have established a novel experimental approach to selectively patch clamp Rab5 positive early endosomes (EE) versus Rab7/LAMP1-positive late endosomes/lysosomes (LE/LY). To functionally characterize ion channels in endolysosomal membranes with the patch-clamp technique, it is important to develop techniques to selectively enlarge the respective organelles. We found here that two small molecules, wortmannin and latrunculin B, enlarge Rab5-positive EE when combined but not Rab7-, LAMP1-, or Rab11 (RE)-positive vesicles. The two compounds act rapidly, specifically, and are readily applicable in contrast to genetic approaches or previously used compounds such as vacuolin, which enlarges EE, RE, and LE/LY. We apply this approach here to measure currents mediated by TRPML channels, in particular TRPML3, which we found to be functionally active in both EE and LE/LY in overexpressing cells as well as in endogenously expressing CD11b+ lung-tissue macrophages. Copyright © 2017 Elsevier Ltd. All rights reserved.
Impulse Testing of Corporate-Fed Patch Array Antennas
NASA Technical Reports Server (NTRS)
Chamberlain, Neil F.
2011-01-01
This paper discusses a novel method for detecting faults in antenna arrays. The method, termed Impulse Testing, was developed for corporate-fed patch arrays where the element is fed by a probe and is shorted at its center. Impulse Testing was devised to supplement conventional microwave measurements in order to quickly verify antenna integrity. The technique relies on exciting each antenna element in turn with a fast pulse (or impulse) that propagates through the feed network to the output port of the antenna. The resulting impulse response is characteristic of the path through the feed network. Using an oscilloscope, a simple amplitude measurement can be made to detect faults. A circuit model of the antenna elements and feed network was constructed to assess various fault scenarios and determine fault-detection thresholds. The experimental setup and impulse measurements for two patch array antennas are presented. Advantages and limitations of the technique are discussed along with applications to other antenna array topologies
2013-01-01
Background Mosquito repellents and emanators confer protection against mosquito bites through spatial action of emanated vapours which are released into the adjoining environment. Synthetic insecticides released into the environment in ultra low volume vapour phase deter the mosquitoes from biting humans in a protected space. Methods Formulation patches were prepared using the solvent evaporation method over a backing membrane and using Dibutylphthalate (DBT) as a plasticizer. The effect of formulation variables on the deltamethrin release from the patch matrices were studied under accelerated conditions, whereas, HPLC was used for quantitative estimation of deltamethrin. The prepared patch formulations were subjected to physicochemical studies, such as, deltamethrin content, thickness, weight variation, percent moisture content, moisture uptake, surface area and surface pH determination. Deltamethrin-polymer interaction and compatibility was ascertained using DSC and FT-IR, while surface morphology and deltamethrin distribution in the patch were studied using SEM technique. Repellent activity of the patch formulations was evaluated against Ae. albopictus mosquitoes. Results Blends of polymeric combinations of polyvinylpyrrolidone (PVP) and ethyl-cellulose (EC) with admixture of deltamethrin provided prolonged repellent activity against Ae. albopictus mosquitoes. Physicochemical characterisation indicated the suitability of deltamethrin patch formulation with the polymeric combinations of PVP and EC. Patches were very effective against laboratory reared Ae. albopictus mosquitoes. No significant difference was observed between the performance of test patches and commercially available repellent cream Mosqshield®. Conclusion Deltamethrin loaded patches provided effective repellency against Ae. albopictus mosquitoes. The study emphasised that deltamethrin released to the environment in low concentration could be an excellent spatial repellent against hematophagous mosquitoes. PMID:24289656
Multiple, Pan-Enteric Perforation Secondary to Intestinal Tuberculosis
Masood, Irfan; Majid, Zain; Rafiq, Ali; Rind, Waqas; Zia, Aisha; Raza, Sajjad
2015-01-01
Free perforation is one of the most feared complications of the intestinal tuberculosis. The terminal ileum is the most common site of perforation, while the majority of (90%) perforations are solitary. Herein, we describe a case of a 25-year-old male who presented with generalized peritonitis requiring an emergency exploratory laparotomy, which revealed pan-enteric perforation characterized by multiple perforations of the small bowel extending 10–15 cm from the DJ flexure up to the terminal ileum. The perforations were primarily closed, while 6–8 cm of the diseased terminal ileum was resected and the two ends were brought out as double-barreled ostomy. To the best of our knowledge, such an extensive tuberculous perforation of the small bowel has not been previously reported in the literature before. PMID:26798540
Whyte, Graeme P; McGee, Alan; Jazrawi, Laith; Meislin, Robert
2016-05-01
To evaluate the fixation integrity at time zero of a type I/III collagen patch secured to a chondral defect in the porcine knee using methods typically employed in autologous chondrocyte implantation (ACI) and matrix-assisted chondrocyte implantation. Twenty-four porcine knee specimens underwent a medial parapatellar arthrotomy. A prefabricated template was used to create cartilage defects of 2 cm(2) in the medial femoral condyle. A size-matched collagen patch was fashioned. Four methods of fixation to the chondral defect were analyzed: group 1-saline, group 2-fibrin glue around the periphery of the patch, group 3-fibrin glue applied to the base of the defect and around the periphery of the patch, group 4-6-0 vicryl suture and fibrin glue around the periphery of the patch. Collagen patch fixation was assessed at intervals of 60, 300, 600, 900, and 1,200 cycles from full extension to 90° of flexion, performed manually without application of axial force. Patch fixation was evaluated by 2 independent observers using a customized scoring scale. Mean peripheral detachment of the patch and chondral defect uncovering remained less than 25% for all groups. Area of defect uncovering was significantly increased in group 2 compared with group 4 after 900 and 1,200 cycles (P = .0014 and P = .0025, respectively). Fibrin glue applied to the base of the defect, or suturing of the patch, reduced deformation significantly after 900 cycles. Suture increases the stability of fixation of a type I/III collagen patch to a chondral defect better than fibrin glue alone in the porcine knee after repetitive cycling, with respect to patch detachment and chondral defect uncovering. Application of fibrin glue to the base of the defect, or securing the patch with suture, decreases collagen patch deformation. In cases where minimally invasive techniques do not allow suture fixation of the collagen patch, scaffold fixation may be compromised during articular motion protocols typically used after second- and third-generation ACI procedures. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Zhang, Xiuling; Dai, Yanhong; Zhang, Shuyi; She, Wandong; Du, Xiaoping; Shui, Xiuji
2012-01-01
Background It has been believed that location of the perforation has a significant impact on hearing loss. However, recent studies have demonstrated that the perforation sites had no impact on hearing loss. We measured the velocity and pattern of the manubrium vibration in guinea pigs with intact and perforated eardrum using a laser Doppler vibrometer in order to determine the effects of different location perforations on the middle ear transfer functions. Methods Two bullas from 2 guinea pigs were used to determine stability of the umbo velocities, and 12 bullas from six guinea pigs to determine the effects of different location perforations on sound transmission. The manubrium velocity was measured at three points on the manubrium in the frequencies of 0.5–8 kHz before and after a perforation was made. The sites of perforations were in anterior-inferior (AI) quadrants of left ears and posterior-inferior (PI) quadrants of right ears. Results The manubrium vibration velocity losses were noticed in the perforated ears only below 1.5 kHz. The maximum velocity loss was about 7 dB at 500 Hz with the PI perforation. No significant difference in the velocity loss was found between AI and PI perforations. The average ratio of short process velocity to the umbo velocity was approximately 0.5 at all frequencies. No significant differences were found before and after perforation at all frequencies (p>0.05) except 7 kHz (p = 0.004) for both AI and PI perforations. Conclusions The manubrium vibration velocity losses from eardrum perforation were frequency-dependent and the largest losses occur at low frequencies. Manubrium velocity losses caused by small acute inferior perforations in guinea pigs have no significant impact on middle ear sound transmission at any frequency tested. The manubrium vibration axis may be perpendicular to the manubrium below 8 kHz in guinea pigs. PMID:22238584
Sugawara, Kotaro; Kawaguchi, Yoshikuni; Nomura, Yukihiro; Koike, Daisuke; Nagai, Motoki; Tanaka, Nobutaka
2017-01-01
The impact of lymph node (LN) dissection on long-term outcomes for patients with colorectal cancer (CRC) perforation remains unclear. We aim to investigate factors associated with poor prognosis and recurrence in patients with CRC, with special reference to cancer perforation and LN dissection. The subjects comprised 550 patients who underwent colorectal surgery for CRC at Stage II or III (TNM classification) between February 2006 and November 2013. Short- and long-term outcomes of patients with or without CRC perforation were evaluated. We also sought risk factors on poor prognosis, focusing on LN dissection in patients with CRC perforation. A total of 508 underwent surgery for CRC without perforation (the non-perforation group) and 39 for CRC with perforation (the perforation group). Both overall survival and recurrence-free survival rates were significantly lower in the perforation group than in the non-perforation group (overall survival, P = 0.009; recurrence-free survival, P < 0.001). The relapse rates at the peritoneum (P = 0.002), lung (P = 0.007) and LNs (P = 0.021) were significantly higher in the perforation group than in the non-perforation group. Multivariable Cox proportional hazards model revealed that CRC perforation (hazard ratio [HR] 2.55, 95 % confidential interval [CI] 1.16-4.98, P = 0.022), LN dissection <12 (HR 1.83, 95 % CI 1.07-3.13, P = 0.027), and Stage III (HR 1.79, 95 % CI 1.06-3.08, P = 0.031) were significant and independent risk factors for poor prognosis. Conducting <12 LN dissections independently increased the risk of reduction in overall survival for patients with CRC perforation. Thus, radical LN dissections should be performed to improve patients' survival rates, when patients' general and surgical conditions allow.
Patch forest: a hybrid framework of random forest and patch-based segmentation
NASA Astrophysics Data System (ADS)
Xie, Zhongliu; Gillies, Duncan
2016-03-01
The development of an accurate, robust and fast segmentation algorithm has long been a research focus in medical computer vision. State-of-the-art practices often involve non-rigidly registering a target image with a set of training atlases for label propagation over the target space to perform segmentation, a.k.a. multi-atlas label propagation (MALP). In recent years, the patch-based segmentation (PBS) framework has gained wide attention due to its advantage of relaxing the strict voxel-to-voxel correspondence to a series of pair-wise patch comparisons for contextual pattern matching. Despite a high accuracy reported in many scenarios, computational efficiency has consistently been a major obstacle for both approaches. Inspired by recent work on random forest, in this paper we propose a patch forest approach, which by equipping the conventional PBS with a fast patch search engine, is able to boost segmentation speed significantly while retaining an equal level of accuracy. In addition, a fast forest training mechanism is also proposed, with the use of a dynamic grid framework to efficiently approximate data compactness computation and a 3D integral image technique for fast box feature retrieval.
Shabbir, Maryam; Ali, Sajid; Raza, Moosa; Sharif, Ali; Akhtar, Furoan Muhammad; Manan, Abdul; Fazli, Ali Raza; Younas, Neelofar; Manzoor, Iqra
2017-01-01
A matrix transdermal patch of bisoprolol fumarate was formulated with different concentrations of Eudragit RS 100 and Methocel E5 with PEG 400 as plasticizer by solvent evaporation technique. Tween 80 was added to the optimized patch to evaluate the effect of permeation enhancer at different concentration through the excised rabbit's skin. The patches were analyzed for weight variation, drug content, swelling index, erosion studies, moisture content, moisture uptake, water vapor transmission rate (WVTR) and water vapor permeability (WVP). In vitro dissolution test was carried out in USP dissolution apparatus V to select the optimized formulation. In vitr skin permeation studies were done in Franz diffusion cell using rabbit skin as a model membrane. The cumulative drug release and flux were determined to compare the result of test patches with a control patch. The greatest enhancement ratio (ER) was obtained in F03-PE with 30% Tween 80. F03-PE seemed to follow zero order kinetics with super case II mechanism of drug release. Statistical ANOVA suggested that there was a significant difference in formulations, steady flux and cumulative permeation rate at different Tween 80 concentrations.
NASA Technical Reports Server (NTRS)
Dean, W. G.
1982-01-01
During prelaunch procedures at Kennedy Space Center some of the EPDM Thermal Protection System material was damaged on the Solid Rocket Booster stiffener stubs. The preferred solution was to patch the damaged areas with a cork-filled epoxy patching compound. Before this was done, however, it was requested that this patching technique be checked out by testing it in the MSFC Hot Gas Facility. Two tests were run in the HFG in 1980. The results showed the patch material to be adequate. Since that time, the formulation of the cork-filled epoxy material has been changed. It became necessary to retest this concept to be sure that the new material is as good as or better than the original material. In addition to the revised formulation material, tests were also made using K5NA as the patch material. The objectives of the tests reported herein were to: (1) compare the thermal performance of the original and the new cork-filled epoxy formulations, and (2) compare the K5NA closeout material to these epoxy materials. Material specifications are also discussed.
Kachhawa, Dilip; Rao, Pankaj; Kalla, Gyaneshwar
2017-01-01
Background and Aims: Stable vitiligo can be treated by various surgical procedures. Non-cultured melanocyte grafting techniques were developed to overcome the time-consuming process of culture while at the same time providing acceptable results. All the techniques using non-cultured melanocyte transfer involve trypsinisation as an integral step. Jodhpur technique used by the author is autologous, non-cultured, non-trypsinised, epidermal cell grafting. Settings and Design: The study was conducted on patients visiting the dermatology outpatient department of a tertiary health centre in Western Rajasthan. Materials and Methods: At the donor site, mupirocin ointment was applied and dermabrasion was done with the help of micromotor dermabrader till pinpoint bleeding was seen. The paste-like material obtained by this procedure containing melanocytes and keratinocytes admixed with the ointment base was harvested with spatula and was subsequently spread over the recipient area. Recipient site was prepared in the same manner by dermabrasion. After 10 days, dressing at both sites was removed taking utmost care at the recipient site as there was a theoretical risk of dislodging epidermal cells. Results: In a study of 437 vitiligo patches, more than 75% re-pigmentation (excellent improvement) was seen in 41% of the patches. Lesions on thigh (100%), face (75%) and trunk (50%) showed maximal excellent improvement, whereas patches on joints and acral areas did not show much improvement. Conclusions: This technique is a simplified, cost effective, less time-consuming alternative to other techniques which involve tryspsinisation of melanocytes and at the same time provides satisfactory uniform pigmentation. PMID:28852293
Intrauterine devices and risk of uterine perforation: current perspectives
Rowlands, Sam; Oloto, Emeka; Horwell, David H
2016-01-01
Uterine perforation is an uncommon complication of intrauterine device insertion, with an incidence of one in 1,000 insertions. Perforation may be complete, with the device totally in the abdominal cavity, or partial, with the device to varying degrees within the uterine wall. Some studies show a positive association between lactation and perforation, but a causal relationship has not been established. Very rarely, a device may perforate into bowel or the urinary tract. Perforated intrauterine devices can generally be removed successfully at laparoscopy. PMID:29386934
Examination of the mechanism of action of two pre-quit pharmacotherapies for smoking cessation.
Ferguson, Stuart G; Walters, Julia A E; Lu, Wenying; Wells, Gudrun P; Schüz, Natalie
2015-12-21
There is substantial scope for improvement in the current arsenal of smoking cessation methods and techniques: even when front-line cessation treatments are utilized, smokers are still more likely to fail than to succeed. Studies testing the incremental benefit of using nicotine patch for 1-4 weeks prior to quitting have shown pre-quit nicotine patch use produces a robust incremental improvement over standard post-quit patch treatment. The primary objective of the current study is to test the mechanism of action of two pre-quit smoking cessation medications-varenicline and nicotine patch-in order to learn how best to optimize these pre-quit treatments. The study is a three group, randomized, open-label controlled clinical trial. Participants (n = 216 interested quitters) will be randomized to receive standard patch treatment (10 weeks of patch starting from a designated quit day), pre-quit patch treatment (two weeks of patch treatment prior to a quit day, followed by 10 weeks post-quit treatment) or varenicline (starting two weeks prior to quit day followed by 10 weeks post-quit). Participants will use study-specific modified smart-phones to monitor their smoking, withdrawal symptoms, craving, mood and social situations in near real-time over four weeks; two weeks prior to an assigned quit date and two weeks after this date. Smoking and abstinence will be assessed at regular study visits and biochemically verified. Understanding how nicotine patches and varenicline influence abstinence may allow for better tailoring of these treatments to individual smokers. Australian New Zealand Clinical Trials Registry, ACTRN12614000329662 (Registered: 27 March 2014).
An unusual case of perforation of the alimentary canal following Bigu
Wang, Jun; Jin, Jun; Xue, Xiaofeng; Hao, Yan; Li, Dongrong; Xu, Shan; Huang, Fang
2017-01-01
Abstract Rationale: Bigu is a Taoist fasting technique interpreted as avoiding grains in the Encyclopedia of China. This technique has been used from ancient times to the present day in China and other parts of the world to achieve good health, weight loss, longevity, and even immortality. A variety of health problems have been identified in relation to the severe diet during Bigu. However, perforation of the alimentary canal has not been reported to be associated with Bigu. In the present study, we illustrated an unusual case of perforation of the alimentary canal in relation to Bigu. Patient concerns: A 36-year-old woman was admitted to our hospital after falling into a coma. One month before admission, she had black stool accompanied by dizziness and fatigue, while the symptoms progressively worsened. The patient reported that she stopped the intake of meat for 5 years, and further practiced Bigu for 5 months, eating only fruits and vegetables, and avoiding grains and meat. Diagnosis: Preformation of the alimentary canal. Interventions: Gastric bypass operation, also known as Roux-en-Y anastomosis, was undertaken. Since the patient developed thrombus with edema on the right upper limb after surgical intervention, she was subsequently treated with anticoagulation therapy using low-molecular weight heparin. Outcomes: The patient's symptoms were remarkably improved and exhibited signs of recovery in follow-up examinations. Lessons: The case has raises serious concerns about practicing Bigu. Furthermore, it is strongly advocated that a state of Bigu for a long period of time can even be dangerous. PMID:29310339
Lynch, Kristle L; Pandolfino, John E; Howden, Colin W; Kahrilas, Peter J
2013-01-01
Background & Aims Pneumatic dilation (PD) and laparoscopic Heller myotomy (LHM) can be definitive therapies for achalasia; recent data suggest comparable efficacy. However, risk must also be considered. We reviewed the major complication rate of PD and LHM in a high volume center and reviewed the corresponding literature. Methods We reviewed 12 years of our institution’s achalasia treatment experience. During this interval a consistent technique of PD was used utilizing Rigiflex dilators. Medical records were reviewed for post-procedure complications. We administered a telephone survey and examined medical records to assess efficacy of treatment. We also performed a systematic review of the literature for comparable clinical data and examined 80 reports encompassing 12,494 LHM and PD procedures. Results At our center, 463 achalasia patients underwent 567 PD or LHM procedures. 78% of the PDs used a 30 mm Rigiflex dilator. 157/184 (85%) patients underwent 1 or 2 PD without any subsequent treatment. There were seven clinically significant perforations; one from PD and 6 from LHM. There were no resultant deaths from these perforations; two deaths occurred within 30 days of LHM from unrelated causes. Complications and deaths post-PD were significantly fewer than those post-LHM (p=.02). Conclusions Esophageal perforation from PD at our high-volume center was less common than often reported and lower than that associated with LHM. We conclude that, in the hands of experienced operators using conservative technique, PD has fewer major complications and deaths than LHM. PMID:23032978
Electrophysiological mechanisms of sophocarpine as a potential antiarrhythmic agent.
Yang, Zhi-fang; Li, Ci-zhen; Wang, Wei; Chen, Ying-min; Zhang, Ying; Liu, Yuan-mou; Wang, Hong-wei
2011-03-01
To examine the electrophysiological effects of sophocarpine on action potentials (AP) and ionic currents of cardiac myocytes and to compare some of these effects with those of amiodarone. Langendorff perfusion set-up was used in isolated guinea pig heart, and responses to sophocarpine were monitored using electrocardiograph. Conventional microelectrode, voltage clamp technique and perforated patch were employed to record fast response AP (fAP), slow response AP (sAP) and ionic currents in guinea pig papillary muscle or rabbit sinus node cells. Tachyarrhythmia produced by isoprenaline (15 μmol/L) could be reversed by sophocarpine (300 μmol/L). Sophocarpine (10 μmol/L) decreased the amplitude by 4.0%, maximal depolarization velocity (V(max)) of the fAP by 24.4%, and Na(+) current (I(Na)) by 18.0%, while it prolonged the effective refractory period (ERP) by 21.1%. The same concentration of sophocarpine could also decrease the amplitude and V(max) of the sAP, by 26.8% and 25.7%, respectively, and attenuated the Ca(2+) current (I(CaL)) and the K(+) tail current substantially. Comparison of sophocarpine with amiodarone demonstrated that both prolonged the duration and the ERP of fAP and sAP, both decreased the amplitude and V(max) of the fAP and sAP, and both slowed the automatic heart rate. Sophocarpine could reverse isoprenaline-induced arrhythmia and inhibit I(Na), I(CaL), and I(Kr) currents. The electrophysiological effects of sophocarpine are similar to those of amiodarone, which might be regarded as a prospective antiarrhythmic agent.
Glove perforation time and frequency in total hip arthroplasty procedures.
Kaya, Ibrahim; Uğraş, Akin; Sungur, Ibrahim; Yilmaz, Murat; Korkmaz, Musa; Cetinus, Ercan
2012-01-01
The aim of the present study was to investigate glove perforation rate and time and evaluate the factors affecting glove perforation in total hip arthroplasty (THA). Nine hundred seventy-nine gloves used in 57 THA procedures were assessed according to the perforation. Forty-four (77.2%) procedures were primary THA and 13 (22.8%) were revision THA. Gloves were changed when perforated, become dirty with blood or blood products, and before bone cementing. All gloves were filled with water at the end of the operation and controlled for perforation. Two hundred and one surgical gloves used during scrubbing and removed after draping the patient were examined as the control group. The location (which finger), number and time of the perforation, surgery type and duration, and distribution of the perforation location according to the surgical team were assessed. Patients' mean age was 62.9 ± 14.6 (range: 33 to 97) years and the mean surgery duration was 162.9 ± 32.0 minutes. Thirty-two glove perforations were noted in 19 of the operations. Of these perforations, 28 belonged to the surgeons and first assistants. There was no significant difference between the dominant or non-dominant hand according to the location of perforations. Perforations in the first and second fingers of the gloves accounted for 81.3% of all perforations. There was no significant difference in terms of number of gloves used, perforation numbers and operation duration between the primary and revision THA procedures. Two perforated gloves (0.99%) were found in the control group and the difference between the number of perforations in the control and study groups was significant (p=0.048). We recommend the use of two pairs of gloves to avoid the risk of contamination and protect the surgical team from infectious disease in major surgeries like THA. Surgical gloves should be changed when they are excessively contaminated with surgical fluids and the surgeon and first assistant should also change their outer gloves at an average of every 90 minutes.
Deep patch technique for landslide repair. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Helwany, B.M.
1994-10-01
The report describes the laboratory testing of the `USFS deep patch` technique and a CTI modification of this technique for repairing landslides with geosynthetic reinforcement. The technique involves replacing sections of roadway lost due to landslides on top of a geosynthetically-reinforced embankment. The CTI modification involves replacing the reinforced slope with a geosynthetically-reinforced retaining wall with a truncated base. Both techniques rely on the cantilevering ability of the reinforced mass to limit the load on the foundation with a high slide potential. The tests with road base showed that (1) both the USFS and CTI repair reduced effectively the adversemore » effects of local landsliding on the highway pavement by preventing crack propagation; (2) the USFS repair increased the stability of the repaired slope, which was in progressive failure, by reducing the stresses exerted on it; and (3) the CTI repair produced substantially greater stresses on its foundation due to the truncated base of the reinforced mass.« less
Two techniques enable sampling of filtered and unfiltered molten metals
NASA Technical Reports Server (NTRS)
Burris, L., Jr.; Pierce, R. D.; Tobias, K. R.; Winsch, I. O.
1967-01-01
Filtered samples of molten metals are obtained by filtering through a plug of porous material fitted in the end of a sample tube, and unfiltered samples are obtained by using a capillary-tube extension rod with a perforated bucket. With these methods there are no sampling errors or loss of liquid.
Comparison of piezosurgery and conventional rotative instruments in direct sinus lifting.
Delilbasi, Cagri; Gurler, Gokhan
2013-12-01
The purpose of this study was to compare the intraoperative and postoperative effects of Piezosurgery and conventional rotative instruments in direct sinus lifting procedure. Twenty-three patients requiring direct sinus lifting were enrolled. The osteotomy and sinus membrane elevation were performed either with Piezosurgery tips or rotative diamond burs and manual membrane elevators. Time elapsed between bony window opening and completion of membrane elevation (duration), incidence of membrane perforation, visibility of the operation site, postoperative pain, swelling, sleeping, eating, phonetics, daily routine, and missed work as well as patient's expectation before and experience after the operation were evaluated. There was no significant difference between Piezosurgery and conventional groups regarding incidence of membrane perforation, duration, and operation site visibility as well as patient's expectation before and experience after the operation (P > 0.05). However, there were significantly more pain and swelling in the conventional group compared with the Piezosurgery group (P ≤ 0.05). Sinus lifting procedure performed with Piezosurgery causes less pain and swelling postoperatively compared with conventional technique. Patients' daily life activities and experience about the operation are not affected from the surgical technique.
NASA Astrophysics Data System (ADS)
Rossi, Francesca; Matteini, Paolo; Ratto, Fulvio; Pini, Roberto; Iacoangeli, Maurizio; Giannoni, Luca; Fortuna, Damiano; Di Cicco, Emiliano; Corbara, Sylwia; Dallari, Stefano
2014-05-01
Laser bonding is a promising minimally invasive approach, emerging as a valid alternative to conventional suturing techniques. It shows widely demonstrated advantages in wound treatment: immediate closuring effect, minimal inflammatory response and scar formation, reduced healing time. This laser based technique can overcome the difficulties in working through narrow surgical corridors (e.g. the modern "key-hole" surgery as well as the endoscopy setting) or in thin tissues that are impossible to treat with staples and/or stitches. We recently proposed the use of chitosan matrices, stained with conventional chromophores, to be used in laser bonding of vascular tissue. In this work we propose the same procedure to perform laser bonding of vocal folds and dura mater repair. Laser bonding of vocal folds is proposed to avoid the development of adhesions (synechiae), after conventional or CO2 laser surgery. Laser bonding application in neurosurgery is proposed for the treatment of dural defects being the Cerebro Spinal Fluid leaks still a major issue. Vocal folds and dura mater were harvested from 9-months old porks and used in the experimental sessions within 4 hours after sacrifice. In vocal folds treatment, an IdocyanineGreen-infused chitosan patch was applied onto the anterior commissure, while the dura mater was previously incised and then bonded. A diode laser emitting at 810 nm, equipped with a 600 μm diameter optical fiber was used to weld the patch onto the tissue, by delivering single laser spots to induce local patch/tissue adhesion. The result is an immediate adhesion of the patch to the tissue. Standard histology was performed, in order to study the induced photothermal effect at the bonding sites. This preliminary experimental activity shows the advantages of the proposed technique in respect to standard surgery: simplification of the procedure; decreased foreign-body reaction; reduced inflammatory response; reduced operating times and better handling in depth.
A Novel Perforator Flap Training Model Using a Chicken Leg
Cifuentes, Ignacio J.; Yañez, Ricardo A.; Salisbury, Maria C.; Rodriguez, José R.; Varas, Julian E.; Dagnino, Bruno L.
2016-01-01
Introduction Living animal models are frequently used for perforator flap dissection training, but no ex vivo models have been described. The aim of this study is to present a novel nonliving model for perforator flap training based on a constant perforator in the chicken leg. Methods A total of 15 chicken legs were used in this study. Anatomical dissection of the perforator was performed after its identification using ink injection, and in four of these specimens a perforator-based flap was raised. Results The anatomical dissection revealed a constant intramuscular perforator with a median length of 5.7 cm. Median proximal and distal vessel diameters were 0.93 and 0.4 mm, respectively. The median dissection time was 77.5 minutes. Conclusion This study introduces a novel, affordable, and reproducible model for the intramuscular dissection of a perforator-based flap using an ex vivo animal model. Its consistent perforator and appropriate-sized vessels make it useful for training. PMID:27616823
Lower Extremity Free Flaps for Breast Reconstruction.
Dayan, Joseph H; Allen, Robert J
2017-11-01
Thigh-based flaps are typically a secondary option for breast reconstruction because of concerns regarding limited tissue volume and donor-site morbidity. In recent years, there have been a number of new techniques and insights that have resulted in greater flexibility and improved outcomes. This article reviews lessons learned from a large collective experience using the following 4 flaps: transverse upper gracilis also known as transverse myocutaneous gracilis, diagonal upper gracilis, profunda artery perforator, and lateral thigh perforator flaps. Flap selection considerations include the patient's fat distribution and skin laxity, perforator anatomy, and scar location. Pearls to minimize donor-site morbidity include avoiding major lymphatic collectors in the femoral triangle and along the greater saphenous vein and respecting the limits of flap dimension to reduce wound healing complications and distal ischemia. Limited flap volume may be addressed with stacking another flap from the contralateral thigh or primary fat grafting as opposed to overaggressive flap harvest from a single thigh. A detailed review of the benefits and disadvantages of each flap and strategies to improve results is discussed. With careful planning and selection, thigh-based flaps can provide a reliable option patients desiring autologous breast reconstruction.
Perforated Pit Membranes in Imperforate Tracheary Elements of Some Angiosperms
SANO, YUZOU; JANSEN, STEVEN
2006-01-01
• Background and Aims The structure of pit membranes in angiosperms has not been fully examined and our understanding about the structure is incomplete. Therefore, this study aims to illustrate the micromorphology of pit membranes in fibres and tracheids of woody species from various families. • Methods Specimens from ten species from ten genera and eight families were prepared using two techniques and examined by field-emission scanning electron microscopy. • Key Results Interfibre pit membranes with an average diameter of <4 µm were frequently perforated or appeared to be very porous. In contrast, pit membranes in imperforate tracheary elements with distinctly bordered pits and an average diameter of ≥4 µm were homogeneous and densely packed with microfibrils. These differences were observed consistently not only among species but also within a single species in which different types of imperforate tracheary elements were present. • Conclusions This study demonstrates that the structure of interfibre pit membranes differs among cell types and the differences are closely associated with the specialization of the fibre cells. It is suggested that perforated pit membranes between specialized fibres contribute to the dehydration of the fibre cells at or soon after maturation. PMID:16520339
Dundar, Riza; Kulduk, Erkan; Soy, Fatih Kemal; Aslan, Mehmet; Yükkaldiran, Ahmet; Çiftçi, Mehmet Ali
2016-09-01
The aim of this study was to compare anatomical and audiological results of boomerang-shaped chondroperichondrial graft (BSCPG) with temporal muscle fascia in type 1 tympanoplasties. Sixty-eight patients in BSCPG group and 54 patients in fascia group were evaluated. Otomicroscopic examination was done periodically till 24 months as for graft perforation, lateralization and retraction and mean air conduction threshold and airbone gap values were measured. At long term controls, in BSCPG group, rates of neomembrane, perforation, retraction and lateralization were 91.17 % (n = 62), 8.82 % (n = 6), 4.41 % (n = 3) and 0 % (n = 0), respectively. In fascia group, the corresponding rates were 79.62 % (n = 43), 20.37 % (n = 11), 12.96 % (n = 7) and 3.7 % (n = 2), respectively. In both groups, mean postoperative PTA and ABG values were significantly better while postoperative same values were significantly different between groups (p = 0.044 and 0.032, respectively). Compared to fascia, BSCPG is an ideal grafting technique in the repair of tympanic membrane perforations.
Acquired perforating dermatosis in a patient with chronic renal failure.
Fernandes, Karen de Almeida Pinto; Lima, Lourenço de Azevedo; Guedes, Juliana Chaves Ruiz; Lima, Ricardo Barbosa; D'Acri, Antônio Macedo; Martins, Carlos José
2016-01-01
Perforating dermatoses are a group of skin diseases characterized by transepidermal elimination of dermal material. The disease is divided into two groups: the primary group and the secondary group. The classical or primary perforating dermatoses are subdivided into four types according to the eliminated dermal materials: Kyrle disease, perforating reactive collagenosis, elastosis perforans serpiginosa, and perforating folliculitis. The secondary form is known as acquired perforating dermatosis. The term was proposed in 1989 by Rapini to designate the perforating dermatoses affecting adult patients with systemic disease, regardless of the dermal materials eliminated. This report describes a case of the disease with elimination of collagen and elastic fibers in a patient with chronic renal failure.
Kitagawa, Yoshiyasu; Suzuki, Takuto; Hara, Taro; Yamaguchi, Taketo
2018-01-01
Although endoscopic submucosal dissection (ESD) is an accepted and established treatment for early esophageal squamous cell carcinoma (EESCC), it is technically difficult, time consuming, and less safe than endoscopic mucosal resection. To perform ESD safely and more efficiently, we proposed a new technique of esophageal ESD using an IT knife nano with the clip traction method. This study aimed to evaluate the efficacy and safety of ESD using this new technique. We retrospectively reviewed all consecutive cases of esophageal ESD performed using an IT knife nano with the clip traction method at our hospital between March 2013 and January 2017. Therapeutic efficacy and safety were also assessed. A total of 103 patients underwent esophageal ESD using the IT knife nano with the clip traction method. In all cases, we performed en bloc resection. Complete resection was achieved in 100 cases (97.1%). The median operating time was 40 (range 13-230) min. No cases of perforation or delayed bleeding occurred. Although two cases (2.0%) of mediastinal emphysema occurred without visible perforation at endoscopy, all were successfully managed conservatively. The new technique of esophageal ESD using the IT knife nano with the clip traction method appears to be feasible, effective, and safe for EESCC treatment.
Changing strategies of the retrograde approach for chronic total occlusion during the past 7 years.
Muramatsu, Toshiya; Tsukahara, Reiko; Ito, Yoshiaki; Ishimori, Hiroshi; Park, Seung-Jung; de Winter, Robert; Shokry, Khaled; Wang, Lefeng; Chen, Jiyan; Wang, Haichang
2013-03-01
We reviewed the technical changes and results achieved with the retrograde approach since we introduced it 7 years ago. The subjects were 1,268 patients who were treated for CTO between January 2004 and December 2010. They were investigated with respect to the success rate, the frequency of employing the retrograde approach and its outcome, and other factors. The retrograde approach was employed in ∼30% of chronic total occlusion (CTO) patients (n = 281) and the retrograde guidewire success rate was 81.1%. The kissing wire technique was substituted for the retrograde approach in 126 of the 281 patients, with antegrade crossing of a guidewire being successful in 88 of them (70%). The retrograde approach was combined with the CART and reverse controlled antegrade retrograde tracking (CART) techniques in 22 and 21 patients, respectively. Among 83 patients treated with Corsair catheters, crossing of the CTO was achieved in 63. The overall procedural success rate was 79.7% (224 patients). Complications of the retrograde approach included collateral channel dissection (2.1%), channel perforation (1.7%), CTO perforation (1.7%), and donor artery occlusion (1.1%). The success rate and safety of the retrograde approach are both satisfactory if the appropriate devices and techniques are selected. Copyright © 2012 Wiley Periodicals, Inc.
Lumbar artery perforators: an anatomical study based on computed tomographic angiography imaging.
Sommeling, Casper Emile; Colebunders, Britt; Pardon, Heleen E; Stillaert, Filip B; Blondeel, Phillip N; van Landuyt, Koenraad
2017-08-01
The free lumbar artery perforator flap has recently been introduced as a potentially valuable option for autologous breast reconstruction in a subset of patients. Up to date, few anatomical studies, exploring the lumbar region as a donor site for perforator- based flaps, have been conducted. An anatomical study of the position of the dominant lumbar artery perforator was performed, using the preoperative computed tomographic angiography images of 24 autologous breast reconstruction patients. In total, 61 dominant perforators were determined, 28 on the left and 33 on the right side. A radiologist defined the position of the perforator as coordinates in an xy-grid. Dominant perforators were shown to originate from the lumbar arteries at the level of lumbar vertebrae three or four. Remarkably, approximately 85% of these lumbar artery perforators enter the skin at 7-10 cm lateral from the midline (mean left 8.6 cm, right 8.2 cm). This study concludes a rather constant position of the dominant perforator. Therefore, preoperative-computed tomographic angiography is not always essential to find this perforator and Doppler ultrasound could be considered as an alternative, thereby carefully assessing all advantages and disadvantages inherent to either of these imaging methods.
Spectrum of perforation peritonitis in India--review of 504 consecutive cases.
Jhobta, Rajender Singh; Attri, Ashok Kumar; Kaushik, Robin; Sharma, Rajeev; Jhobta, Anupam
2006-09-05
Perforation peritonitis is the most common surgical emergency in India. The spectrum of etiology of perforation in Tropical countries continues to be different from its Western counterpart. The objective of the study was to highlight the spectrum of perforation peritonitis as encountered by us at Government Medical College and Hospital (GMCH), Chandigarh. Five hundred and four consecutive cases of perforation peritonitis over a period of five years were reviewed in terms of clinical presentation, operative findings and postoperative course retrospectively at GMCH, Chandigarh. The most common cause of perforation in our series was perforated duodenal ulcer (289 cases) followed by appendicitis (59 cases), gastrointestinal perforation due to blunt trauma abdomen (45 cases), typhoid fever (41 cases) and tuberculosis (20 cases). Despite delay in seeking medical treatment (53%), the overall mortality (10%) was favourably comparable with other published series though the overall morbidity (50%) was unusually high. In contrast to western literature, where lower gastrointestinal tract perforations predominate, upper gastrointestinal tract perforations constitute the majority of cases in India. The increasing incidence of post-traumatic gastro-enteric injuries may be due to an increase in high speed motor vehicle accidents which warrant early recognition and prompt treatment to avoid serious complications and death.
Causes and Outcomes of Esophageal Perforation in Eosinophilic Esophagitis.
Runge, Thomas M; Eluri, Swathi; Cotton, Cary C; Burk, Caitlin M; Woosley, John T; Shaheen, Nicholas J; Dellon, Evan S
2017-10-01
To characterize patients who suffer perforation in the context of eosinophilic esophagitis (EoE) and to identify predictors of perforation. Esophageal perforation is a serious complication of EoE. We conducted a retrospective cohort study of the University of North Carolina EoE clinicopathologic database from 2001 to 2014. Subjects were included if they had an incident diagnosis of EoE and met consensus guidelines, including nonresponse to a PPI trial. Patients with EoE who had suffered perforation at any point during their course were identified, and compared with EoE cases without perforation. Multiple logistic regression was performed to determine predictors of perforation. Out of 511 subjects with EoE, 10 (2.0%) had experienced an esophageal perforation. Although those who perforated tended to have a longer duration of symptoms before diagnosis (11.4 vs. 7.0 y, P=0.13), a history of food impaction (odds ratio, 14.9; 95% confidence interval, 1.7-129.2) and the presence of a focal stricture (odds ratio, 4.6; 95% confidence interval, 1.1-19.7) were the only factors independently associated with perforation. Most perforations (80%) occurred after a prolonged food bolus impaction, and only half of individuals (5/10) carried a diagnosis of EoE at the time of perforation; none occurred after dilation. Six patients (60%) were treated with nonoperative management, and 4 (40%) required surgical repair. Esophageal perforation is a rare but serious complication of eosinophilic esophagitis, occurring in ∼2% of cases. Most episodes are due to food bolus impaction or strictures, suggesting that patients with fibrostenotic disease due to longer duration of symptoms are at increased risk.
Bladder perforations in children.
Bakal, U; Sarac, M; Tartar, T; Ersoz, F; Kazez, A
2015-01-01
Bladder perforations in children occur due to several different reasons. In this clinical series study, we focused on bladder perforations due to the pelvic injury, and our aim also was to create awareness for a rare type of bladder injuries. This was a retrospective study of the patients who were treated in our clinic for bladder perforation between 2006 and 2011. We reviewed the documents of childhood bladder perforations, and demographic and clinical characteristics of the patients were obtained. No statistical analyses were used because of the limited number of cases. There were ten patients who suffered from bladder perforation in 5-year period; 5 were male, and 5 were female. The mean age of the patients was 4.35 years. Four patients (40%) experienced iatrogenic perforation and six patients (60%) experienced perforation due to the accident. Common symptoms were hematuria, abdominal tenderness, and inability to urinate. Three patients were diagnosed via emergency laparotomy, without any radiological examinations performed before surgery. Four patients suffered from the intraperitoneal perforation, three patients suffered from extraperitoneal injury and three of them both of intraperitoneal and extraperitoneal injuries. Mean recovery time for patients was 15 days. One patient developed a urinary tract infection and one newborn died due to accompanying morbidities. Nine patients were discharged from the hospital. If the patients had a pelvic injury, surgeons must pay attention for the bladder perforation. Isolated bladder perforations are rare, and they are generally associated with iatrogenic injuries. Clinicians should pay attention to findings such as anuria, inability to insert a urinary catheter, and free fluid in the abdomen in order to diagnose the bladder perforation in newborns. Novice surgeons should pay more attention to avoid causing iatrogenic bladder perforation during inguinal hernia repair.
Quallich, Stephen G; Van Heel, Michael; Iaizzo, Paul A
2015-02-01
Catheter perforations remain a major clinical concern during ablation procedures for treatment of atrial arrhythmias and may lead to life-threatening cardiac tamponade. Radiofrequency (RF) ablation alters the biomechanical properties of cardiac tissue, ultimately allowing for perforation to occur more readily. Studies on the effects of cryoablation on perforation force as well as studies defining the perforation force of human tissue are limited. The purpose of this study was to investigate the required force to elicit perforation of cardiac atrial tissue after or during ablation procedures. Effects of RF or cryothermal ablations on catheter perforation forces for both swine (n = 83 animals, 530 treatments) and human (n = 8 specimens, 136 treatments) cardiac tissue were investigated. Overall average forces resulting in perforation of healthy unablated tissue were 406g ± 170g for swine and 591g ± 240g for humans. Post-RF ablation applications considerably reduced these forces to 246g ± 118g for swine and 362 ± 185g for humans (P <.001). Treatments with cryoablation did not significantly alter forces required to induce perforations. Decreasing catheter sizes resulted in a reduction in forces required to perforate the atrial wall (P <.001). Catheter perforations occurred over an array of contact forces with a minimum of 38g being observed. The swine model likely underestimates the required perforation forces relative to those of human tissues. We provide novel insights related to the comparative effects of RF and cryothermal ablations on the potential for inducing undesired punctures, with RF ablation reducing perforation force significantly. These data are insightful for physicians performing ablation procedures as well as for medical device designers. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Holland, Roberto; Bisco Ferreira, Luciana; de Souza, Valdir; Otoboni Filho, José Arlindo; Murata, Sueli Satomi; Dezan, Eloi
2007-10-01
It has been shown that the mineral trioxide aggregate (MTA) used to seal lateral/furcal perforations stimulates the deposition of newly formed cementum. Nevertheless, when the site of the perforation is contaminated, the healing process might occur under less favorable conditions. This study evaluated the repair healing process of noncontaminated and contaminated lateral perforations filled with MTA and the effect of previously filling the contaminated perforations with a bactericidal agent. Thirty lateral root perforations were prepared in endodontically treated dog's teeth, thus forming 3 groups with 10 specimens each. In group 1 the perforations were immediately sealed with MTA. In group 2 the perforations were left open for 7 days and thereafter sealed with MTA. In group 3 the perforations were left open for 7 days, filled temporarily with a calcium hydroxide-based paste for 14 days, and then sealed with MTA. The animals were killed after 90 days, and the pieces were prepared for histomorphologic and histomicrobiologic evaluations. The statistical analysis showed that group 1 had significantly better repair than groups 2 (P < .05) and 3 (P < .05), which validates the superior results obtained when MTA was immediately used to seal root perforations. Groups 2 and 3 had statistically similar repair to each other (P > .05). There were a larger number of cases of complete or partial biologic seal in group 1 compared with the contaminated groups. It might be concluded that the lateral root perforations sealed with MTA after contamination presented worse repair than the noncontaminated, immediately sealed perforations. The temporary filling with a bactericidal agent (calcium hydroxide-based paste) did not improve the repair of perforations exposed to contamination, and the contaminated groups presented similar results to each other.
Acoustical properties of materials and muffler configurations for the 80 by 120 foot wind tunnel
NASA Technical Reports Server (NTRS)
Scharton, T. D.; Sneddon, M. D.
1977-01-01
Techniques for measuring the impedance of the muffler configurations and of porous plates with grazing flow were investigated and changes in the configuration parameters to enhance acoustic performance are explored. The feasibility of a pulse reflection technique for measuring the impedance of built-up structures in situ was demonstrated. A second technique involving the use of an open-end impedance tube with grazing flow was used to obtain detailed design data for the perforated plate configuration. Acoustic benefits associated with configuration changes such as curving the baffles, spacing and staggering baffle partitions, and techniques for alleviating baffle self-generated noise are described.
Legemate, Catherine M; van der Kwaak, Monique; Gobets, David; Huikeshoven, Menno; van Zuijlen, Paul P M
2018-06-01
The ischial region is the site most affected by pressure sores and has the highest recurrence and complication rates compared to other affected sites. We developed a practical and safe pedicled flap for reconstruction of ischial pressure sores based on the rich available perforators from the internal pudendal artery and the surplus of skin at the infragluteal fold. A retrospective cohort study was conducted in all patients who underwent ischial pressure ulcer reconstruction using the PIPAP flap between March 2010 and March 2017. The skin flap was designed along the gluteal fold. The skin perforators of the pudendal artery were marked with a Doppler probe in the medial region of the gluteal fold. Surgery was performed in the jackknife position, and flaps were elevated in the suprafascial plane. Patients were assessed for minor (requiring no additional surgery) and major complications (requiring additional surgery). Twenty-seven patients (34 flaps) were identified. The median follow-up period was 38 months (IQR 37). Primary closure of the donor-site was achieved in all procedures, only one flap required muscle flap transposition in order to fill the dead space. The mean operating time was 60 ± 21 minutes. In six flaps (9%) wound healing problems were noted that did not require an additional operative procedure. Among the nine flaps (27%) that required a second procedure, 3 (9%) were necessary due to recurrent ulcers. The PIPAP flap is a safe and reliable alternative for ischial pressure sore reconstruction, certainly when compared to available techniques. Moreover, it has significant advantages over other techniques including minimal donor-site morbidity, preservation of posterior thigh skin, buttock-line integrity and reliable vascularity. Copyright © 2018 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Wadaani, Hamed Al
2013-03-08
BACKGROUND/ PURPOSE: Perforated peptic ulcer (PPU) is still an existing disease that occurs frequently in the 21st century despite of the wide availability of antiulcer medication and Helicobacter eradication. The current study aimed to evaluate the hypothesis that its outcome might be improved by using the laparoscopy. The outcome of treatment in terms of complications, mortality and hospital stay with relevant to laparoscopy was analyzed. This prospective descriptive study was carried on the period of 3 years from July 2009 till July 2012. All patients with acute abdominal pain that was clinically diagnosed as having perforated peptic ulcer were included. Excluded from this study were those patients with concomitant bleeding from the ulcer and evidence of gastric outlet obstructions. Also excluded were those with evidence of large perforation more than 10 mm and patients with symptoms of more than 36 h durations for fear of septic shock. Forty seven patients were studied out of a total 53 PPU patients; they were 41 males and 6 females with the male to female ratio of 6.8:1. Their age ranged from 19 to 55 years with the mean age of 39.5 ± 8.6 years. Forty five patients were successfully treated by laparoscopy while only 2 cases that were early presented with signs of hypovolumic shock were converted into laparotomy due to severe bleeding. The mean hospital stay was 75 ± 12.6 h. Post operative complications included death of one patient in the postoperative period at the Intensive care unit (ICU) plus post operative fever in the 2 patients who underwent laparotomy and it was amenable to treatment. Laparoscopic repair of a perforated peptic ulcer is an amenable and feasible technique within the hands of experienced laparoscopic surgeon when the cases are early and properly diagnosed.
2013-01-01
Background/ purpose Perforated peptic ulcer (PPU) is still an existing disease that occurs frequently in the 21st century despite of the wide availability of antiulcer medication and Helicobacter eradication. The current study aimed to evaluate the hypothesis that its outcome might be improved by using the laparoscopy. The outcome of treatment in terms of complications, mortality and hospital stay with relevant to laparoscopy was analyzed. Patients and methods This prospective descriptive study was carried on the period of 3 years from July 2009 till July 2012. All patients with acute abdominal pain that was clinically diagnosed as having perforated peptic ulcer were included. Excluded from this study were those patients with concomitant bleeding from the ulcer and evidence of gastric outlet obstructions. Also excluded were those with evidence of large perforation more than 10 mm and patients with symptoms of more than 36 h durations for fear of septic shock. Results Forty seven patients were studied out of a total 53 PPU patients; they were 41 males and 6 females with the male to female ratio of 6.8:1. Their age ranged from 19 to 55 years with the mean age of 39.5 ± 8.6 years. Forty five patients were successfully treated by laparoscopy while only 2 cases that were early presented with signs of hypovolumic shock were converted into laparotomy due to severe bleeding. The mean hospital stay was 75 ± 12.6 h. Post operative complications included death of one patient in the postoperative period at the Intensive care unit (ICU) plus post operative fever in the 2 patients who underwent laparotomy and it was amenable to treatment. Conclusions Laparoscopic repair of a perforated peptic ulcer is an amenable and feasible technique within the hands of experienced laparoscopic surgeon when the cases are early and properly diagnosed. PMID:23497473
Image superresolution of cytology images using wavelet based patch search
NASA Astrophysics Data System (ADS)
Vargas, Carlos; García-Arteaga, Juan D.; Romero, Eduardo
2015-01-01
Telecytology is a new research area that holds the potential of significantly reducing the number of deaths due to cervical cancer in developing countries. This work presents a novel super-resolution technique that couples high and low frequency information in order to reduce the bandwidth consumption of cervical image transmission. The proposed approach starts by decomposing into wavelets the high resolution images and transmitting only the lower frequency coefficients. The transmitted coefficients are used to reconstruct an image of the original size. Additional details are added by iteratively replacing patches of the wavelet reconstructed image with equivalent high resolution patches from a previously acquired image database. Finally, the original transmitted low frequency coefficients are used to correct the final image. Results show a higher signal to noise ratio in the proposed method over simply discarding high frequency wavelet coefficients or replacing directly down-sampled patches from the image-database.
Wysocki, Andrzej; Budzyński, Piotr; Kulawik, Jan; Drożdż, Włodzimierz
2011-04-01
Throughout recent decades there has been noticeable change in the incidence of peptic ulcer disease and its complications. The aim of the present study was to determine the character of changes over the last 45 years in the localization of perforation, in patient age, and in patient gender. A group of 881 patients admitted to the Second Department of General Surgery in Krakow, Poland, from 1962 to 2006 were included in the study and constituted the material for the analysis. The study was divided into three time periods (1962-1976, 1977-1991, and 1992-2006) to allow statistical analysis of trends. The general incidence of perforations of peptic ulcer did not show changes; however, the percentage of women with perforated duodenal ulcer markedly increased. Patients with perforated stomach ulcer--regardless of gender--and females suffering from perforated duodenal ulcer were, on the average, about 10 years older than males with perforated duodenal ulcers. The mean age of male and female patients with perforated duodenal ulcer over the last 45 years showed an insignificant upward trend. (1) The percentage of women with perforated duodenal ulcer continuously and statistically significantly rose. (2) Men with perforated duodenal ulcer were significantly younger than other patients. (3) The mean ages of male and female patients with perforated duodenal ulcer over the last 45 years showed an insignificant upward trend.
Duodenal perforation: an unusual complication of sickle cell anemia.
Acıpayam, Can; Aldıç, Güliz; Akçora, Bülent; Çelikkaya, Mehmet Emin; Aşkar, Hasan; Dorum, Bayram Ali
2014-01-01
Duodenal perforation in childhood is a rare condition with a high mortality rate if not treated surgically. Primary gastroduodenal perforation is frequently associated with peptic ulcer and exhibits a positive family history. Helicobacter pylorus is the most significant agent. Secondary gastroduodenal perforation may be a finding of specific diseases, such as Crohn disease, or more rarely may be associated with diseases such as cystic fibrosis or sickle cell anemia. A 14-year-old boy presented with abdominal and back pain. The patient was operated on for acute abdomen and diagnosed with duodenal perforation. Helicobacter pylorus was negative. There was no risk factor to account for duodenal perforation other than sickle cell anemia. Surgical intervention was successful and without significant sequelae. Duodenal perforation is a rare entity described in patients with sickle cell anemia. To our knowledge, this is the first report of duodenal perforation in a patient sickle cell anemia.
Duodenal perforation: an unusual complication of sickle cell anemia
Acıpayam, Can; Aldıç, Güliz; Akçora, Bülent; Çelikkaya, Mehmet Emin; Aşkar, Hasan; Dorum, Bayram Ali
2014-01-01
Duodenal perforation in childhood is a rare condition with a high mortality rate if not treated surgically. Primary gastroduodenal perforation is frequently associated with peptic ulcer and exhibits a positive family history. Helicobacter pylorus is the most significant agent. Secondary gastroduodenal perforation may be a finding of specific diseases, such as Crohn disease, or more rarely may be associated with diseases such as cystic fibrosis or sickle cell anemia. A 14-year-old boy presented with abdominal and back pain. The patient was operated on for acute abdomen and diagnosed with duodenal perforation. Helicobacter pylorus was negative. There was no risk factor to account for duodenal perforation other than sickle cell anemia. Surgical intervention was successful and without significant sequelae. Duodenal perforation is a rare entity described in patients with sickle cell anemia. To our knowledge, this is the first report of duodenal perforation in a patient sickle cell anemia. PMID:25422692
Patch-test reactions to plastic and glue allergens.
Kanerva, L; Jolanki, R; Alanko, K; Estlander, T
1999-07-01
Plastics and glues are common causes of occupational dermatoses, but only few reports have dealt with patch-test reactions caused by plastic and glue allergens. Patients exposed to plastics and remitted to an occupational dermatology clinic, were patch-tested with 50-53 plastic and glue allergens during a 6-year period. Conventional patch-test techniques were used. The most common causes of allergic patch-test reactions in 360 patients were novolac epoxy resin (5.1%), phenol formaldehyde resin (3.1%), 4-tert-butylcatechol (2.6%), phenyl glycidyl ether (2.6%), diaminodiphenyl methane (2.2%), benzoyl peroxide (2.2%), hexamethylene tetramine (2.0%) and o-cresyl glycidyl ether (1.6%). The allergens that most often elicited irritant patch-test reactions were: benzoyl peroxide (9.5%), abitol alcohol (3.6%), hydroquinone (3.1%), acid-catalyzed phenol formaldehyde resin (2.5%) and toluene diisocyanate (1.9%). Twenty-six out of 53 chemicals caused no allergic reaction during the 6-year period. Plastic allergens in the standard series provoked allergic reactions with formaldehyde (5.8%), diglycidyl ether of bisphenol A (3.2%), 4-tert-butylphenol-formaldehyde-resin (1.1%), toluene sulphonamide formaldehyde-resin (1.1%) and triethylenglycol diacrylate (0.4%). Although half of the plastic chemicals gave no allergic patch-test reactions during a 6-year period, with unusual allergens this low yield needs to be accepted, because otherwise rare allergies will not be detected. Also a negative reaction has diagnostic value.
Motomura, Yasuaki; Akahoshi, Kazuya; Gibo, Junya; Kanayama, Kenji; Fukuda, Shinichiro; Hamada, Shouhei; Otsuka, Yoshihiro; Kubokawa, Masaru; Kajiyama, Kiyoshi; Nakamura, Kazuhiko
2014-01-01
AIM: To investigate the causes and intraoperative detection of endoscopic retrograde cholangiopancreatography (ERCP)-related perforations to support immediate or early diagnosis. METHODS: Consecutive patients who underwent ERCP procedures at our hospital between January 2008 and June 2013 were retrospectively enrolled in the study (n = 2674). All procedures had been carried out using digital fluoroscopic assistance with the patient under conscious sedation. For patients showing alterations in the gastrointestinal anatomy, a short-type double balloon enteroscope had been applied. Cases of perforation had been identified by the presence of air in or leakage of contrast medium into the retroperitoneal space, or upon endoscopic detection of an abdominal cavity related to the perforated lumen. For patients with ERCP-related perforations, the data on medical history, endoscopic findings, radiologic findings, diagnostic methods, management, and clinical outcomes were used for descriptive analysis. RESULTS: Of the 2674 ERCP procedures performed during the 71-mo study period, only six (0.22%) resulted in perforations (male/female, 2/4; median age: 84 years; age range: 57-97 years). The cases included an endoscope-related duodenal perforation, two periampullary perforations related to endoscopic sphincterotomy, two periampullary perforations related to endoscopic papillary balloon dilation, and a periampullary or bile duct perforation secondary to endoscopic instrument trauma. No cases of guidewire-related perforation occurred. The video endoscope system employed in all procedures was only able to immediately detect the endoscope-related perforation; the other five perforation cases were all detected by subsequent digital fluoroscope applied intraoperatively (at a median post-ERCP intervention time of 15 min). Three out of the six total perforation cases, including the single case of endoscope-related duodenal injury, were surgically treated; the remaining three cases were treated with conservative management, including trans-arterial embolization to control the bleeding in one of the cases. All patients recovered without further incident. CONCLUSION: ERCP-related perforations may be difficult to diagnose by video endoscope and digital fluoroscope detection of retroperitoneal free air or contrast medium leakage can facilitate diagnosis. PMID:25400465
Three-point bending of honeycomb sandwich beams with facesheet perforations
NASA Astrophysics Data System (ADS)
Su, Pengbo; Han, Bin; Zhao, Zhongnan; Zhang, Qiancheng; Lu, Tian Jian
2017-12-01
A novel square honeycomb-cored sandwich beam with perforated bottom facesheet is investigated under three-point bending, both analytically and numerically. Perforated square holes in the bottom facesheet are characterized by the area ratio of the hole to intact facesheet (perforation ratio). While for large-scale engineering applications like the decks of cargo vehicles and transportation ships, the perforations are needed to facilitate the fabrication process (e.g., laser welding) as well as service maintenance, it is demonstrated that these perforations, when properly designed, can also enhance the resistance of the sandwich to bending. For illustration, fair comparisons among competing sandwich designs having different perforation ratios but equal mass is achieved by systematically thickening the core webs. Further, the perforated sandwich beam is designed with a relatively thick facesheet to avoid local indention failure so that it mainly fails in two competing modes: (1) bending failure, i.e., yielding of beam cross-section and buckling of top facesheet caused by bending moment; (2) shear failure, i.e., yielding and buckling of core webs due to shear forcing. The sensitivity of the failure loads to the ratio of core height to beam span is also discussed for varying perforation ratios. As the perforation ratio is increased, the load of shear failure increases due to thickening core webs, while that of bending failure decreases due to the weakening bottom facesheet. Design of a sandwich beam with optimal perforation ratio is realized when the two failure loads are equal, leading to significantly enhanced failure load (up to 60% increase) relative to that of a non-perforated sandwich beam with equal mass.
The Heidelberg Appendicitis Score Predicts Perforated Appendicitis in Children.
Boettcher, Michael; Günther, Patrick; Breil, Thomas
2017-10-01
In the future, surgical management of pediatric appendicitis might become limited to nonperforating appendicitis. Thus, it becomes increasingly important to differentiate advanced from simple appendicitis and to predict perforated appendicitis among a group of children with right-sided abdominal pain, which was the aim of this study. An institutionally approved, single-center retrospective analysis of all patients with appendectomy from January 2009 to December 2010 was conducted. All diagnostic aspects were evaluated to identify predictors and differentiators of perforated appendicitis. In 2 years, 157 children suffered from appendicitis. Perforation occurred in 47 (29.9%) of the patients. C-reactive protein (CRP) levels higher than 20 mg/dL ( P = .037) and free abdominal fluid on ultrasonography ( P = .031) are the most important features to differentiate perforated from simple appendicitis. Moreover, all children with perforation had a positive Heidelberg Appendicitis Score (HAS). A negative HAS excludes perforation in all cases (negative predictive value = 100%). Perforated appendicitis can be ruled out by the HAS. In a cohort with right-sided abdominal pain, perforation should be considered in children with high CRP levels and free fluids or abscess formation on ultrasound.
Reliable harvest of a dorsal scapular artery perforator flap by augmenting its perfusion.
Kim, So-Young; Lee, Kyeong-Tae; Mun, Goo-Hyun
2016-02-01
Despite confirmation of a reliable perforasome in the dorsal scapular artery in an anatomic study, a true perforator flap has not been recommended in previous clinical studies because of concerns regarding insufficient perfusion in the distal region. In this report, we present two cases of reconstruction for occipital defects caused by tumor extirpation using pedicled dorsal scapular artery perforator flaps without a muscle component. To secure the perfusion of the dorsal scapular artery perforator flap, inclusion of an additional perforator was attempted for perfusion augmentation. The second dorsal scapular artery perforator was harvested in one case. In an additional case, the sixth dorsal intercostal artery perforator with a branch that directly connected with the dorsal scapular artery within the trapezius muscle was additionally harvested. The flaps survived without any perfusion-related complications, including tip necrosis, and no donor site morbidities were observed. We suggest that a perfusion augmented dorsal scapular artery perforator flap by harvesting multiple perforators could be a safe and useful alternative for reconstructive surgery of head and neck defects. © 2014 Wiley Periodicals, Inc.
Intersection of three-dimensional geometric surfaces
NASA Technical Reports Server (NTRS)
Crisp, V. K.; Rehder, J. J.; Schwing, J. L.
1985-01-01
Calculating the line of intersection between two three-dimensional objects and using the information to generate a third object is a key element in a geometry development system. Techniques are presented for the generation of three-dimensional objects, the calculation of a line of intersection between two objects, and the construction of a resultant third object. The objects are closed surfaces consisting of adjacent bicubic parametric patches using Bezier basis functions. The intersection determination involves subdividing the patches that make up the objects until they are approximately planar and then calculating the intersection between planes. The resulting straight-line segments are connected to form the curve of intersection. The polygons in the neighborhood of the intersection are reconstructed and put back into the Bezier representation. A third object can be generated using various combinations of the original two. Several examples are presented. Special cases and problems were encountered, and the method for handling them is discussed. The special cases and problems included intersection of patch edges, gaps between adjacent patches because of unequal subdivision, holes, or islands within patches, and computer round-off error.
Shin, Woong-Hee; Kihara, Daisuke
2018-01-01
Virtual screening is a computational technique for predicting a potent binding compound for a receptor protein from a ligand library. It has been a widely used in the drug discovery field to reduce the efforts of medicinal chemists to find hit compounds by experiments.Here, we introduce our novel structure-based virtual screening program, PL-PatchSurfer, which uses molecular surface representation with the three-dimensional Zernike descriptors, which is an effective mathematical representation for identifying physicochemical complementarities between local surfaces of a target protein and a ligand. The advantage of the surface-patch description is its tolerance on a receptor and compound structure variation. PL-PatchSurfer2 achieves higher accuracy on apo form and computationally modeled receptor structures than conventional structure-based virtual screening programs. Thus, PL-PatchSurfer2 opens up an opportunity for targets that do not have their crystal structures. The program is provided as a stand-alone program at http://kiharalab.org/plps2 . We also provide files for two ligand libraries, ChEMBL and ZINC Drug-like.
Libondi, Guido; Ramakrishnan, Venkat
2017-01-01
Background The transverse upper gracilis (TUG) flap is the senior authors’ second choice for autologous breast reconstruction when the DIEP flap is not available. It provides durable, pliable tissue with well hidden scars. The main criticism of this flap is the limited volume, donor site complications, short pedicle and vessel mismatch depending on which recipient vessels are used. We described methods of reducing vessel mismatch, complications of venous coupler and refinements to help give a more superior aesthetic outcome. Methods We describe several maneuvers to help reduce vessel mismatch with the use of the internal mammary (IM) perforator vessels with a modification of the Harashina fish-mouth technique or the use of a vessel bifurcation to increase vessel diameter. We also describe the optimum method of perforator preparation and potential methods to prevent palpable venous couplers. The author’s describe their case series of 14 TUG flaps to reconstruct 13 breasts in 12 patients. Results Eight unilateral, 2 partial breast reconstruction, 1 bilateral and 1 bilateral TUG flap for a unilateral reconstruction was carried out. All flaps survived with one partial flap necrosis, one donor site seroma and two cases of palpable/tender venous couplers. The mean reconstructed breast was 320 grams. Conclusions The TUG flap is a reconstructive challenge, but with correct planning a good aesthetic outcome is possible. The IM perforator is our first choice recipient vessel in TUG breast reconstructions. With meticulous preparation and by overcoming vessel mismatch the use of this recipient vessel is a reliable option. PMID:28861378
Zakine, Gilbert; Baruch, Jean; Dardour, Jean-Claude; Flageul, Gérard
2015-03-01
Perforation of one or several intraperitoneal organs during a liposuction procedure is an exceptional but underestimated complication. Knowledge of this complication is essential because of frequent delay in diagnosis and possible dramatic consequences. Nineteen cases were evaluated by experts and are presented in a retrospective analysis. Sixteen women and three men, aged 24 to 72 years, were operated on in France between July of 2001 and January of 2012. Abdominal liposuction (200 to 2400 ml) was performed in combination or not with an abdominoplasty. Uncommon pain and an intestinal obstruction were present in all of the patients. The peritonitis was never frank, replaced frequently by infraclinic peritonitis with septic and/or hypovolemic shock. Diagnosis, performed by abdominal scan between days 1 and 7, revealed intraperitoneal gas or liquid. Perforation, unique or multiple, because of the intraperitoneal passage of the cannula, often in the umbilical region and promoted by the presence of a hernia, involved the following organs: ileum (14 cases), jejunum (two cases), spleen (two cases), transverse colon (one case), cecum (one case), and sigmoid (one case). Death occurred in three cases, between days 2 and 11. Eleven patients had temporary ileostomy or colostomy. Associated complications were abdominal wall cellulitis, necrotizing fasciitis, thrombophlebitis, lung collection, and late subobstructive syndrome. Visceral perforation during liposuction, a severe and sometimes fatal complication with late and difficult diagnosis, is not often reported. Careful technique, particularly if an umbilical approach is used, should avoid this dramatic complication. Therapeutic, IV.
Advances in imaging technologies for planning breast reconstruction
Mohan, Anita T.
2016-01-01
The role and choice of preoperative imaging for planning in breast reconstruction is still a disputed topic in the reconstructive community, with varying opinion on the necessity, the ideal imaging modality, costs and impact on patient outcomes. Since the advent of perforator flaps their use in microsurgical breast reconstruction has grown. Perforator based flaps afford lower donor morbidity by sparing the underlying muscle provide durable results, superior cosmesis to create a natural looking new breast, and are preferred in the context of radiation therapy. However these surgeries are complex; more technically challenging that implant based reconstruction, and leaves little room for error. The role of imaging in breast reconstruction can assist the surgeon in exploring or confirming flap choices based on donor site characteristics and presence of suitable perforators. Vascular anatomical studies in the lab have provided the surgeon a foundation of knowledge on location and vascular territories of individual perforators to improve our understanding for flap design and safe flap harvest. The creation of a presurgical map in patients can highlight any abnormal or individual anatomical variance to optimize flap design, intraoperative decision-making and execution of flap harvest with greater predictability and efficiency. This article highlights the role and techniques for preoperative planning using the newer technologies that have been adopted in reconstructive clinical practice: computed tomographic angiography (CTA), magnetic resonance angiography (MRA), laser-assisted indocyanine green fluorescence angiography (LA-ICGFA) and dynamic infrared thermography (DIRT). The primary focus of this paper is on the application of CTA and MRA imaging modalities. PMID:27047790
Visible and near infrared resonance plasmonic enhanced nanosecond laser optoporation of cancer cells
St-Louis Lalonde, Bastien; Boulais, Étienne; Lebrun, Jean-Jacques; Meunier, Michel
2013-01-01
In this paper, we report a light driven, non-invasive cell membrane perforation technique based on the localized field amplification by a nanosecond pulsed laser near gold nanoparticles (AuNPs). The optoporation phenomena is investigated with pulses generated by a Nd:YAG laser for two wavelengths that are either in the visible (532 nm) or near infrared (NIR) (1064 nm). Here, the main objective is to compare on and off localized surface plasmonic resonance (LSPR) to introduce foreign material through the cell membrane using nanosecond laser pulses. The membrane permeability of human melanoma cells (MW278) has been successfully increased as shown by the intake of a fluorescent dye upon irradiation. The viability of this laser driven perforation method is evaluated by propidium iodide exclusion as well as MTT assay. Our results show that up to 25% of the cells are perforated with 532 nm pulses at 50 mJ/cm2 and around 30% of the cells are perforated with 1064 nm pulses at 1 J/cm2. With 532 nm pulses, the viability 2 h after treatment is 64% but it increases to 88% 72 h later. On the other hand, the irradiation with 1064 nm pulses leads to an improved 2 h viability of 81% and reaches 98% after 72 h. Scanning electron microscopy images show that the 5 pulses delivered during treatment induce changes in the AuNPs size distribution when irradiated by a 532 nm beam, while this distribution is barely affected when 1064 nm is used. PMID:23577284
Postoperative Gastric Perforation in a Newborn with Duodenal Atresia.
Antabak, Anko; Bogović, Marko; Vuković, Jurica; Grizelj, Ruža; Babić, Vinka Barbarić; Papeš, Dino; Luetić, Tomislav
2016-01-01
Gastric perforation (GP) in neonates is a rare entity with high mortality. Although the etiology is not completely understood, it mostly occurs in premature neonates on assisted ventilation. Combination of duodenal atresia and gastric perforation is very rare. We present a case duodenal atresia who developed gastric perforation after operetion for duodenal atresia. Analysis of the patient medical record and histology report did not reveal the etiology of the perforation.
Shin, Dong Hyuk; Cho, Young Suk; Kim, Yoon Sung; Ahn, Hee Cheol; Oh, Young Taeck; Park, Sang O; Won, Moo-Ho; Cho, Jun Hwi; Kim, Young Myeong; Seo, Jeong Yeol; Lee, Young Hwan
2018-01-01
Delta neutrophil index (DNI) is a new inflammatory marker and the present study aimed to evaluate the predictive value of the DNI for the presence of a perforation in elderly with acute appendicitis. This retrospective observational study was conducted on 108 consecutive elderly patients (≥65 years old) with acute appendicitis treated over a 24-month period. Sixty-nine of the 108 patients (median, IQR: 72, 67-77 years) were allocated to the perforated appendicitis group (63.9%) and 39 to the non-perforated appendicitis group (36.1%). WBC, neutrophil-to-lymphocyte ratio, platelet-to-lymphocyte ratio and DNI were significantly higher in the perforated group. In multiple logistic regression analyses, initial DNI was the only independent marker that can significantly predict the presence of perforation in multiple regression [odds ratio 9.38, 95% confidence interval (2.51-35.00), P=.001]. Receiver operator characteristic curve analysis showed that DNI is a good predictor for the presence of appendiceal perforation at an optimal cut-off for DNI being 1.4% (sensitivity 67.7%, specificity 90.0%, AUC 0.807). Clinicians can reliably differentiate acute perforated appendicitis from non-perforated appendicitis by DNI level of 1.4 or more in elderly patients. © 2017 Wiley Periodicals, Inc.
Porcine experimental model for perforator flap raising in reconstructive microsurgery.
González-García, José A; Chiesa-Estomba, Carlos M; Álvarez, Leire; Altuna, Xabier; García-Iza, Leire; Thomas, Izaskun; Sistiaga, Jon A; Larruscain, Ekhiñe
2018-07-01
Perforator free flap-based reconstruction of the head and neck is a challenging surgical procedure and needs a steep learning curve. A reproducible mammal large animal model with similarities to human anatomy is relevant for perforator flap raising and microanastomosis. The aim of this study was to assess the feasibility of a swine model for perforator-based free flaps in reconstructive microsurgery. Eleven procedures were performed under general anesthesia in a porcine model, elevating a skin flap vascularized by perforating musculocutaneous branches of the superior epigastric artery to evaluate the relevance of this model for head and neck reconstructive microsurgery. The anterior abdominal skin perforator-based free flap in a swine model irrigated by the superior epigastric artery was elevated in eleven procedures. In six of these procedures, we could perform an arterial and venous microanastomosis to the great vessels located in the base of the neck. The porcine experimental model of superior epigastric artery perforator-based free flap reconstruction offers relevant similarities to the human deep inferior epigastric artery perforator flap. We could demonstrate this model as acceptable for perforator free flap training due to the necessity of perforator and pedicle dissection and transfer to a distant area. Copyright © 2018 Elsevier Inc. All rights reserved.
Glove perforation in hip and knee arthroplasty.
Demircay, Emre; Unay, Koray; Bilgili, Mustafa G; Alataca, Gulum
2010-11-01
The transmission of blood-borne pathogens during surgery is a major concern. Surgical gloves are the primary barrier between the surgeon and the patient. Surgical procedures that need manual handling of bony surfaces or sharp instruments have the highest risk of glove perforations. The frequencies and the sites of surgical glove perforations in arthroplasty procedures were assessed. We assessed the surgical glove perforations in total hip and knee arthroplasty procedures. Double standard latex gloves were used. A total of 983 outer and 511 inner gloves were tested. The gloves of all the surgical team members were tested for perforations during the first and second hours of surgery. There were 18.4% outer and 8.4% inner glove perforations. The most frequent site of perforation was the second digit of the nondominant hand (25.5%). We found that hip and knee arthroplasty had significantly more glove perforation risk for the surgeon in the first half of the operation rather than the second half, and 57.8% of the perforations were at the index finger and the thumb. Arthroplasty procedures still have high glove perforation rates despite the use of double gloving with frequent changes. Extra augmentation of the gloves in selected areas of the hand, in addition to double gloving, may be safer and more cost-effective than double gloving alone.
Conserved size and periodicity of pyramidal patches in layer 2 of medial/caudal entorhinal cortex
Naumann, Robert K.; Ray, Saikat; Prokop, Stefan; Las, Liora; Heppner, Frank L.
2016-01-01
ABSTRACT To understand the structural basis of grid cell activity, we compare medial entorhinal cortex architecture in layer 2 across five mammalian species (Etruscan shrews, mice, rats, Egyptian fruit bats, and humans), bridging ∼100 million years of evolutionary diversity. Principal neurons in layer 2 are divided into two distinct cell types, pyramidal and stellate, based on morphology, immunoreactivity, and functional properties. We confirm the existence of patches of calbindin‐positive pyramidal cells across these species, arranged periodically according to analyses techniques like spatial autocorrelation, grid scores, and modifiable areal unit analysis. In rodents, which show sustained theta oscillations in entorhinal cortex, cholinergic innervation targeted calbindin patches. In bats and humans, which only show intermittent entorhinal theta activity, cholinergic innervation avoided calbindin patches. The organization of calbindin‐negative and calbindin‐positive cells showed marked differences in entorhinal subregions of the human brain. Layer 2 of the rodent medial and the human caudal entorhinal cortex were structurally similar in that in both species patches of calbindin‐positive pyramidal cells were superimposed on scattered stellate cells. The number of calbindin‐positive neurons in a patch increased from ∼80 in Etruscan shrews to ∼800 in humans, only an ∼10‐fold over a 20,000‐fold difference in brain size. The relatively constant size of calbindin patches differs from cortical modules such as barrels, which scale with brain size. Thus, selective pressure appears to conserve the distribution of stellate and pyramidal cells, periodic arrangement of calbindin patches, and relatively constant neuron number in calbindin patches in medial/caudal entorhinal cortex. J. Comp. Neurol. 524:783–806, 2016. © 2015 The Authors. The Journal of Comparative Neurology Published by Wiley Periodicals, Inc. PMID:26223342
Conserved size and periodicity of pyramidal patches in layer 2 of medial/caudal entorhinal cortex.
Naumann, Robert K; Ray, Saikat; Prokop, Stefan; Las, Liora; Heppner, Frank L; Brecht, Michael
2016-03-01
To understand the structural basis of grid cell activity, we compare medial entorhinal cortex architecture in layer 2 across five mammalian species (Etruscan shrews, mice, rats, Egyptian fruit bats, and humans), bridging ∼100 million years of evolutionary diversity. Principal neurons in layer 2 are divided into two distinct cell types, pyramidal and stellate, based on morphology, immunoreactivity, and functional properties. We confirm the existence of patches of calbindin-positive pyramidal cells across these species, arranged periodically according to analyses techniques like spatial autocorrelation, grid scores, and modifiable areal unit analysis. In rodents, which show sustained theta oscillations in entorhinal cortex, cholinergic innervation targeted calbindin patches. In bats and humans, which only show intermittent entorhinal theta activity, cholinergic innervation avoided calbindin patches. The organization of calbindin-negative and calbindin-positive cells showed marked differences in entorhinal subregions of the human brain. Layer 2 of the rodent medial and the human caudal entorhinal cortex were structurally similar in that in both species patches of calbindin-positive pyramidal cells were superimposed on scattered stellate cells. The number of calbindin-positive neurons in a patch increased from ∼80 in Etruscan shrews to ∼800 in humans, only an ∼10-fold over a 20,000-fold difference in brain size. The relatively constant size of calbindin patches differs from cortical modules such as barrels, which scale with brain size. Thus, selective pressure appears to conserve the distribution of stellate and pyramidal cells, periodic arrangement of calbindin patches, and relatively constant neuron number in calbindin patches in medial/caudal entorhinal cortex. © 2015 The Authors. The Journal of Comparative Neurology Published by Wiley Periodicals, Inc.
Kimura, T; Goto, H; Takeuchi, Y; Yoshida, M; Kobayashi, T; Sakuramachi, S; Harada, Y
1996-09-01
Gallbladder perforation often occurs during laparoscopic cholecystectomy. The frequency and causes of gallbladder perforation as well as the relevant clinical background factors were investigated in 110 patients undergoing laparoscopic cholecystectomy. We also evaluated intraperitoneal contamination by bacteria and gallstones at the time of gallbladder perforation and investigated whether perforation caused early or late postoperative complications. Intraoperative gallbladder perforation occurred in 29 of the 110 patients (26.3%). It was caused by injury with an electric knife during dissection of the gallbladder bed, injury during gallbladder retraction with grasping forceps, injury during gallbladder extraction from the abdomen, and slippage of cystic duct clips (potentially causing bile and stone spillage). Perforation was more frequent in patients with positive bile cultures and in those with pigment stones (p < 0.02), but not in patients with cholecystitis or cystic duct obstruction. The peritoneal cavity was contaminated by bacteria in 11/29 patients (37.9%) and by spilled stones in 3/29 patients (10.3%). There was no difference in the incidence of postoperative complications between the patients with and without perforation either in the early postoperative period or during follow-up for 24-42 months. Only one patient developed abdominal pain and fever in the early postoperative period, and they were probably related to perforation. Although gallbladder perforation is sometimes unavoidable during laparoscopic cholecystectomy, the risk of severe complications appears to be minimized by early closure of perforation, retrieval of as many of the spilled stones as possible, and intraperitoneal lavage.
Unal, Cigdem; Ozdemir, Jale; Yirmibesoglu, Oktay; Yucel, Ergin; Agir, Hakan
2012-07-01
Reconstructive surgery for ischial pressure sore defects presents a challenge because of high rates of recurrence. The aim of this study was to describe the use of inferior gluteal artery (IGA) and posterior thigh perforators in management of ischial pressure sores with limited donor sites. Between September 2005 and 2009, 11 patients (9 male, 2 female) with ischial sores were operated by using IGA and posterior thigh perforator flaps. The data of patients included age, sex, cause of paraplegia, flap size, perforator of flap, previous surgeries, recurrences, complications, and postoperative follow-up. Nine IGA and 5 posterior thigh perforator flaps were used. Six patients presented with recurrent lesions, 5 patients were operated for sacral and contralateral ischial pressure sores previously. In 2 patients, IGA and posterior thigh perforator flaps were used in combination. Patients were followed for an average of 34.3 months. In 2 recurrent cases, readvancement of IGA perforator flap and gluteus maximus myocutaneous flap were treatment of choice. Treatment of patients with recurrent lesions or multiple pressure sores is challenging because of limited available flap donor sites. In this study, posterior thigh perforator flaps were preferred in patients in whom the previous donor site was the gluteal region. IGA perforator flaps were the treatment of choice in patients for whom posterior thigh region was previously used. Alternately, preserved perforators of previous conventional myocutaneous flaps enabled us to use these perforators in recurrences.
Kim, Jong Gyu
2012-01-01
Background During the planning of a thoracodorsal artery perforator (TDAP) free flap, preoperative multidetector-row computed tomographic (MDCT) angiography is valuable for predicting the locations of perforators. However, CT-based perforator mapping of the thoracodorsal artery is not easy because of its small diameter. Thus, we evaluated 1-mm-thick MDCT images in multiple planes to search for reliable perforators accurately. Methods Between July 2010 and October 2011, 19 consecutive patients (13 males, 6 females) who underwent MDCT prior to TDAP free flap operations were enrolled in this study. Patients ranged in age from 10 to 75 years (mean, 39.3 years). MDCT images were acquired at a thickness of 1 mm in the axial, coronal, and sagittal planes. Results The thoracodorsal artery perforators were detected in all 19 cases. The reliable perforators originating from the descending branch were found in 14 cases, of which 6 had transverse branches. The former were well identified in the coronal view, and the latter in the axial view. The location of the most reliable perforators on MDCT images corresponded well with the surgical findings. Conclusions Though MDCT has been widely used in performing the abdominal perforator free flap for detecting reliable perforating vessels, it is not popular in the TDAP free flap. The results of this study suggest that multiple planes of MDCT may increase the probability of detecting the most reliable perforators, along with decreasing the probability of missing available vessels. PMID:22872839
Risk factors associated with conversion of laparoscopic simple closure in perforated duodenal ulcer.
Kim, Ji-Hyun; Chin, Hyung-Min; Bae, You-Jin; Jun, Kyong-Hwa
2015-03-01
Precise patient selection criteria are necessary to guide the surgeon in selecting laparoscopic repair for patients with perforated peptic ulcers. The aims of this study are to report surgical outcomes after surgery for perforated duodenal ulcers and identify risk factors for predicting failure of laparoscopic simple closure for perforated duodenal ulcer. In total, 77 patients who underwent laparoscopic simple closure for perforated duodenal ulcers from January 2007 to September 2013 were retrospectively analyzed. Patients were divided into totally laparoscopic and conversion groups. The characteristics of patients, intraoperative findings, postoperative complications, conversion rates and suture leakage rates of each group were investigated. Laparoscopic repair was completed in 69 (89.6%) of 77 patients, while 8 (10.4%) underwent conversion to open repair. Patients in the conversion group had longer perforation time, larger perforation size, more suture leakage, longer hospital stay, and higher 30-day mortality rate than those in the totally laparoscopic group. The size of perforation was the only risk factor for conversion in multivariable analysis. Patients with an ulcer perforation size of ≥9 mm or with perforation duration of ≥12.5 h had a significantly increased risk for conversion and suture leakage. Ulcer size of ≥9 mm is a significant risk factor for predicting conversion in laparoscopic simple closure. Suture leakage is associated with ulcer size (9 mm) and duration of perforation (12.5 h). Copyright © 2015 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.
Enhancing SMAP Soil Moisture Retrievals via Superresolution Techniques
NASA Astrophysics Data System (ADS)
Beale, K. D.; Ebtehaj, A. M.; Romberg, J. K.; Bras, R. L.
2017-12-01
Soil moisture is a key state variable that modulates land-atmosphere interactions and its high-resolution global scale estimates are essential for improved weather forecasting, drought prediction, crop management, and the safety of troop mobility. Currently, NASA's Soil Moisture Active/Passive (SMAP) satellite provides a global picture of soil moisture variability at a resolution of 36 km, which is prohibitive for some hydrologic applications. The goal of this research is to enhance the resolution of SMAP passive microwave retrievals by a factor of 2 to 4 using modern superresolution techniques that rely on the knowledge of high-resolution land surface models. In this work, we explore several super-resolution techniques including an empirical dictionary method, a learned dictionary method, and a three-layer convolutional neural network. Using a year of global high-resolution land surface model simulations as training set, we found that we are able to produce high-resolution soil moisture maps that outperform the original low-resolution observations both qualitatively and quantitatively. In particular, on a patch-by-patch basis we are able to produce estimates of high-resolution soil moisture maps that improve on the original low-resolution patches by on average 6% in terms of mean-squared error, and 14% in terms of the structural similarity index.
Permeation and gating properties of the L-type calcium channel in mouse pancreatic beta cells
1993-01-01
Ba2+ currents through L-type Ca2+ channels were recorded from cell- attached patches on mouse pancreatic beta cells. In 10 mM Ba2+, single- channel currents were recorded at -70 mV, the beta cell resting membrane potential. This suggests that Ca2+ influx at negative membrane potentials may contribute to the resting intracellular Ca2+ concentration and thus to basal insulin release. Increasing external Ba2+ increased the single-channel current amplitude and shifted the current-voltage relation to more positive potentials. This voltage shift could be modeled by assuming that divalent cations both screen and bind to surface charges located at the channel mouth. The single- channel conductance was related to the bulk Ba2+ concentration by a Langmuir isotherm with a dissociation constant (Kd(gamma)) of 5.5 mM and a maximum single-channel conductance (gamma max) of 22 pS. A closer fit to the data was obtained when the barium concentration at the membrane surface was used (Kd(gamma) = 200 mM and gamma max = 47 pS), which suggests that saturation of the concentration-conductance curve may be due to saturation of the surface Ba2+ concentration. Increasing external Ba2+ also shifted the voltage dependence of ensemble currents to positive potentials, consistent with Ba2+ screening and binding to membrane surface charge associated with gating. Ensemble currents recorded with 10 mM Ca2+ activated at more positive potentials than in 10 mM Ba2+, suggesting that external Ca2+ binds more tightly to membrane surface charge associated with gating. The perforated-patch technique was used to record whole-cell currents flowing through L-type Ca2+ channels. Inward currents in 10 mM Ba2+ had a similar voltage dependence to those recorded at a physiological Ca2+ concentration (2.6 mM). BAY-K 8644 (1 microM) increased the amplitude of the ensemble and whole-cell currents but did not alter their voltage dependence. Our results suggest that the high divalent cation solutions usually used to record single L-type Ca2+ channel activity produce a positive shift in the voltage dependence of activation (approximately 32 mV in 100 mM Ba2+). PMID:7687645
Yin, Xinghong; Hu, Wei; Zhang, Xinhai; Sun, Min
2014-10-01
To explore curative effect with pedicle flap of nasal septum-basis nasi and temporal muscucofascial flap to repair nasal septal perforation. Dissecting mucoperichondrium and mucoperioseptum around the perforation and taking dowm and out xia-ward to the floor of nasal cavity to make a inferior extremity pedicle flap. Then,the flap was tumbled and sutured onto raw surface of contralateral side through perforation. Reapplicating autoallergic temporal musculofascial flap to repair another side perforation. Repairing perforation Sin twelve cases were sucessfully healed in endoscope. The pedicle flap of nasal septum-basis nasi and temporal muscucofascial flap is easy to acquire and no rejection. The flap has good blood supplying, high survival rate and provides adequate transplantating materail to repair comparatively large perforation.
Postoperative Gastric Perforation in a Newborn with Duodenal Atresia
Antabak, Anko; Bogović, Marko; Vuković, Jurica; Grizelj, Ruža; Babić, Vinka Barbarić; Papeš, Dino; Luetić, Tomislav
2016-01-01
Gastric perforation (GP) in neonates is a rare entity with high mortality. Although the etiology is not completely understood, it mostly occurs in premature neonates on assisted ventilation. Combination of duodenal atresia and gastric perforation is very rare. We present a case duodenal atresia who developed gastric perforation after operetion for duodenal atresia. Analysis of the patient medical record and histology report did not reveal the etiology of the perforation. PMID:27896170
Seow, J G; Lim, Y R; Shelat, V G
2017-06-01
Perforated peptic ulcer (PPU) is a common surgical emergency and treatment involves omental patch repair (PR). Gastric resection (GR) is reserved for difficult pathologies. We audit the outcomes of GR at our institution and evaluate the pre-operative factors predicting the need for GR. This is a single-institution, retrospective study of patients with PPU who underwent surgery from 2004 to 2012. Demographics, clinical presentation and intra-operative findings were studied to identify factors predicting the need for GR in PPU. An audit of clinical outcomes and mortality for all patients with GR is reported. 537 (89.6 %) patients underwent PR and 62 (10.4 %) patients GR. Old age (p < 0.0001), female sex (p = 0.0123), non-steroidal anti-inflammatory drugs (NSAIDs) usage (p = 0.0008), previous history of peptic ulcer disease (PUD) (p = 0.0159), low hemoglobin (p < 0.0001), low serum albumin (p < 0.0001), high serum creatinine (p = 0.0030), high urea (p = 0.0006) and large ulcer size (p < 0.0001) predict the need for GR. On multivariate analysis only low serum albumin (OR 5.57, 95 % CI 1.56-19.84, p = 0.008) predicted the need for GR. The presence of Helicobacter pylori infection was protective against GR (OR 0.25, 95 %CI 0.14-0.44, p < 0.0001). Morbidity and mortality of GR was 27.7 and 24.2 %, respectively. GR is needed in one in ten cases of PPU. Low serum albumin predicted the need for GR on multivariate analysis. Morbidity and mortality of GR remains high.
Schietroma, Mario; Cecilia, Emanuela Marina; De Santis, Giuseppe; Carlei, Francesco; Pessia, Beatrice; Amicucci, Gianfranco
2016-02-01
The clinical role of hyperoxia for preventing surgical site infection (SSI) remains uncertain because randomized controlled trials on this topic have reported disparate results. One of the principal reasons for this outcome may be that prior trials have entered heterogeneous populations of patients and a variety of procedures. The aim of our study was to assess the influence of hyperoxygenation on SSI using a homogeneous study population. From January 2004 to April 2013, we studied, in a randomized trial, 239 patients, who underwent open surgery for perforated peptic ulcer (PPU). The surgical procedure was performed through an upper abdominal midline incision, and closure of PPU was achieved by suture alone or in combination with an omental patch. Patients were assigned randomly to an oxygen/air mixture with a fraction of inspired oxygen (FiO2) of 30% (n = 120) or 80% (n = 119). Administration was commenced after induction of anesthesia and maintained for 6 hours after surgery. The overall incision infection rate was 38.4% (92 of 239): 61 patients (50.8%) had an infection in the 30% FiO2 group and 31 (26%) in the 80% FiO2 group (p < 0.05). The risk of SSI was 48% lower in the 80% FiO2 group (relative risk 0.51; 95% confidence interval [CI] 0.28-1.08) vs 30% FiO2. Supplemental 80% FiO2 during and for 6 h after open surgery for PPU, which reduces post-operative SSI, should be considered part of ongoing quality improvement activities related to surgical care, with few risks to the patient and little associated cost.
Experimental Fatigue Study of Composite Patch Repaired Steel Plates with Cracks
NASA Astrophysics Data System (ADS)
Karatzas, Vasileios A.; Kotsidis, Elias A.; Tsouvalis, Nicholas G.
2015-10-01
Cracks are among the most commonly encountered defects in metallic structures operating at sea. Composite patch repairing is a repair method which is gaining popularity as it counters most of the problems faced by conventional renewal repairs. Extensive studies can be found in the literature addressing the efficiency of this novel repair method using techniques which meet higher performance and monitoring standards than these commonly found in naval applications. In this work the efficiency of practices widely used in the ship repair industry for the implementation of composite patch repairing is addressed. To this end, steel plates repaired with composite patches were tested under fatigue loading. The composite patches consisted of carbon fibers in epoxy matrix and were directly laminated to the steel surface using the vacuum infusion method. Two different surface preparation methods, namely grit-blasting and mechanical treatment with the use of a needle gun were studied. In addition, in order to account for the harsh environmental conditions during the operating life of the structure and to study its effect on the repair, two different aging scenarios were considered. Non-destructive evaluation of the patches was performed so as to assess the quality of the repair, and the evolution of debonding during testing.
Cavallari, Cristina; Brigidi, Patrizia; Fini, Adamo
2015-12-30
The aim of the present study was to evaluate the gel-forming polysaccharide psyllium in the preparation of mucoadhesive patches for the controlled release of chlorhexidine (CHX) to treat pathologies in the oral cavity, using the casting-solvent evaporation technique. A number of different film-forming semi-synthetic polymers, such as sodium carboxymethyl cellulose (SCMC) and hydroxypropylmethyl cellulose (HPMC) were evaluated for comparison. The patch formulations were characterized in terms of drug content, morphology surface, swelling and mucoadhesive properties, microbiology inhibition assay and in vitro release tests. Three ex-vivo testswere carried out using porcine mucosa: an alternative dissolution test using artificial saliva that allows contemporary measurement of dissolution and mucoadhesion, a permeation test through the mucosa and the measurement of mucoadhesion using a Nouy tensile tester, as the maximum force required for the separation of the patch from the mucosa surface. The patches were also examined for determination of the minimum inhibitory concentration in cultures of Escherichia coli and Staphylococcus aureus. All the patches incorporating psyllium were found suitable in terms of external morphology, mucoadhesion and controlled release of the drug: in the presence of psyllium the drug displays prolonged zero-order release related to slower swelling rate of the system. Copyright © 2015. Published by Elsevier B.V.
Geometry analysis for landscape fragmentation in coastal areas of China
NASA Astrophysics Data System (ADS)
Zhang, Tianhai; Yu, Ning; Mu, Hongdu; Tuo, Tao
2017-08-01
In recent years, the continuous expansion of urban-transport networks in China has aggravated the fragmentation of regional landscapes and led to the degradation of multiple ecological functions. In this study, Geographic Information System (GIS) techniques, patch size of fragmentation geometry were used to identify and monitor spatial distribution patterns of landscape fragmentation due to urban-transport networks in Fujian Province. This network has caused serious damage to regional ecological functions, and risks to the persistence of animal populations and biodiversity. This analysis revealed that the smallest patch class (0-15 km2) occurred with a much greater frequency than all other larger patch sizes. In the coastal cities of Xiamen, Zhangzhou and Quanzhou, the percentage of the number of patches less than 300 km2 was higher than in the western cities of Nanping, Sanming and Longyan, and the percentage of the area of patches less than 300 km2 was also higher. Based on a holistic identification of the structure of the network and its landscape division, we found that: Fujian Province has a spatial pattern of landscape fragmentation, with less fragmentation in western and northern regions, and most fragmentation in southern and eastern regions. Coastal regions and areas close to the main transport routes were more seriously fragmented and contained most of the small patches.
Microchip amplifier for in vitro, in vivo, and automated whole cell patch-clamp recording
Kolb, Ilya; Kodandaramaiah, Suhasa B.; Chubykin, Alexander A.; Yang, Aimei; Bear, Mark F.; Boyden, Edward S.; Forest, Craig R.
2014-01-01
Patch clamping is a gold-standard electrophysiology technique that has the temporal resolution and signal-to-noise ratio capable of reporting single ion channel currents, as well as electrical activity of excitable single cells. Despite its usefulness and decades of development, the amplifiers required for patch clamping are expensive and bulky. This has limited the scalability and throughput of patch clamping for single-ion channel and single-cell analyses. In this work, we have developed a custom patch-clamp amplifier microchip that can be fabricated using standard commercial silicon processes capable of performing both voltage- and current-clamp measurements. A key innovation is the use of nonlinear feedback elements in the voltage-clamp amplifier circuit to convert measured currents into logarithmically encoded voltages, thereby eliminating the need for large high-valued resistors, a factor that has limited previous attempts at integration. Benchtop characterization of the chip shows low levels of current noise [1.1 pA root mean square (rms) over 5 kHz] during voltage-clamp measurements and low levels of voltage noise (8.2 μV rms over 10 kHz) during current-clamp measurements. We demonstrate the ability of the chip to perform both current- and voltage-clamp measurement in vitro in HEK293FT cells and cultured neurons. We also demonstrate its ability to perform in vivo recordings as part of a robotic patch-clamping system. The performance of the patch-clamp amplifier microchip compares favorably with much larger commercial instrumentation, enabling benchtop commoditization, miniaturization, and scalable patch-clamp instrumentation. PMID:25429119
Dermal exposure to monoterpenes during wood work.
Eriksson, Kare; Wiklund, Leif
2004-06-01
The dermal exposure to the suspected allergenic monoterpenes [small alpha]-pinene, [small beta]-pinene and [capital Delta](3)-carene was assessed with a patch sampling technique. The patch used was made of activated charcoal sandwiched between two layers of cotton cloth. Patches were fastened at 12 different spots on a sampling overall and at the front of a cap to estimate the potential exposure of the body. Fastening two patches on a cotton glove, one patch representing the dorsal side and one patch representing the palm of the hand respectively, assessed the exposure on the hands. Sampling was carried out during collecting of pine and spruce boards in sawmills and during sawing of pine wood pieces in joinery shops respectively. The potential dermal exposure of the total body was 29.0-1 890 mg h(-1) with a geometric mean (GM) of 238 mg h(-1) during sawing. During collecting the GM was estimated to 100 mg h(-1) with a range of 12.2-959 mg h(-1). The hands had a mean exposure of 9.24 mg h(-1) during sawing and 3.25 mg h(-1) during collecting respectively. The good correlation between the mass of contamination on the individual body parts and the potential body exposure indicates that sampling can be performed on one body part to give a good estimation of the potential body exposure. Monoterpenes were detected at patches fastened underneath the protective clothing indicating a contamination of the skin of the worker. The patch used may overestimate the dermal exposure.
Kamenskiy, Alexey V.; Pipinos, Iraklis I.; MacTaggart, Jason N.; Jaffar Kazmi, Syed A.; Dzenis, Yuris A.
2011-01-01
Patch angioplasty is the most common technique used for the performance of carotid endarterectomy. A large number of patching materials are available for use while new materials are being continuously developed. Surprisingly little is known about the mechanical properties of these materials and how these properties compare with those of the carotid artery wall. Mismatch of the mechanical properties can produce mechanical and hemodynamic effects that may compromise the long-term patency of the endarterectomized arterial segment. The aim of this paper was to systematically evaluate and compare the biaxial mechanical behavior of the most commonly used patching materials. We compared PTFE (n = 1), Dacron (n = 2), bovine pericardium (n = 10), autogenous greater saphenous vein (n = 10), and autogenous external jugular vein (n = 9) with the wall of the common carotid artery (n = 18). All patching materials were found to be significantly stiffer than the carotid wall in both the longitudinal and circumferential directions. Synthetic patches demonstrated the most mismatch in stiffness values and vein patches the least mismatch in stiffness values compared to those of the native carotid artery. All biological materials, including the carotid artery, demonstrated substantial nonlinearity, anisotropy, and variability; however, the behavior of biological and biologically-derived patches was both qualitatively and quantitatively different from the behavior of the carotid wall. The majority of carotid arteries tested were stiffer in the circumferential direction, while the opposite anisotropy was observed for all types of vein patches and bovine pericardium. The rates of increase in the nonlinear stiffness over the physiological stress range were also different for the carotid and patching materials. Several carotid wall samples exhibited reverse anisotropy compared to the average behavior of the carotid tissue. A similar characteristic was observed for two of 19 vein patches. The obtained results quantify, for the first time, significant mechanical dissimilarity of the currently available patching materials and the carotid artery. The results can be used as guidance for designing more efficient patches with mechanical properties resembling those of the carotid wall. The presented systematic comparative mechanical analysis of the existing patching materials provides valuable information for patch selection in the daily practice of carotid surgery and can be used in future clinical studies comparing the efficacy of different patches in the performance of carotid endarterectomy. PMID:22168740
Xu, Songtao; Sheng, Weixin; Qiu, Yufa; Wang, Jianguo
2016-01-01
Ventriculoperitoneal (V-P) shunt surgery is the most common technique used for the treatment of hydrocephalus. The migration of ventriculoperitoneal shunt to the bladder is rare. Only two cases have been previously reported in the literature. We report on a 38-year-old male who had hydrocephalus and V-P shunt for 12 years. Two years ago, he found himself with recurrent urinary tract infections, haematuria and urges incontinence, and then he was diagnosed with bladder perforation and merge stones. The patient had an abdominal operation to cut off and take out the shunt catheter, as well as a transurethral holmium laser lithotripsy. Bladder perforation and stones are rare examples of complications in V-P surgical procedures. Controlling the effective length of the terminal V-P shunt and modifying it appropriately can effectively reduce these complications.
[Perforated peptic ulcer closure: laparoscopic or open?
Alekberzade, A V; Krylov, N N; Rustamov, E A; Badalov, D A; Popovtsev, M A
To compare laparoscopic and open closure of perforated peptic ulcer (PPU). The study included 153 patients who underwent PPU suturing. 78 patients underwent laparoscopic closure (laparoscopic group) and open suturing via upper midline laparotomy was performed in 75 cases (open group). Surgery time, postoperative pain severity, time of analgesics intake, postoperative complications, hospital-stay and and cosmetic effect were compared. Laparoscopic PPU closure may be effective and accessible in experienced endoscopic surgeon. It significantly reduces postoperative pain severity, need for analgesics, incidence of postoperative complications and provides excellent cosmetic effect. However, there is greater time of surgery compared with open intervention. There were no significant differences in hspital-stay between groups. Laparoscopic PPU suturing can be considered a good alternative to open surgery. Further researches are needed for standardization, assessment of safety, real advantages and disadvantages of laparoscopic technique.
Hypopharyngeal perforation near-miss during transesophageal echocardiography.
Aviv, Jonathan E; Di Tullio, Marco R; Homma, Shunichi; Storper, Ian S; Zschommler, Anne; Ma, Guoguang; Petkova, Eva; Murphy, Mark; Desloge, Rosemary; Shaw, Gary; Benjamin, Stanley; Corwin, Steven
2004-05-01
The traditional blind passage of a transesophageal echocardiography probe transorally through the hypopharynx is considered safe. Yet, severe hypopharyngeal complications during transesophageal echocardiography at several institutions led the authors to investigate whether traditional probe passage results in a greater incidence of hypopharyngeal injuries when compared with probe passage under direct visualization. Randomized, prospective clinical study. In 159 consciously sedated adults referred for transesophageal echocardiography, the authors performed transesophageal echocardiography with concomitant transnasal videoendoscopic monitoring of the hypopharynx. Subjects were randomly assigned to receive traditional (blind) or experimental (optical) transesophageal echocardiography. The primary outcome measure was frequency of hypopharyngeal injuries (hypopharyngeal lacerations or hematomas), and the secondary outcome measure was number of hypopharyngeal contacts. No perforation occurred with either technique. However, hypopharyngeal lacerations or hematomas occurred in 19 of 80 (23.8%) patients with the traditional technique (11 superficial lacerations of pyriform sinus, 1 laceration of pharynx, 12 arytenoid hematomas, 2 vocal fold hematomas, and 1 pyriform hematoma) and in 1 of 79 patients (1.3%) with the optical technique (superficial pyriform laceration) (P =.001). All traumatized patients underwent flexible laryngoscopy, but none required additional intervention. Respectively, hypopharyngeal contacts were more frequent with the traditional than with the optical technique at the pyriform sinus (70.0% vs. 10.1% [P =.001]), arytenoid (55.0% vs. 3.8% [P =.001]), and vocal fold (15.0% vs. 3.86% [P =.016]). Optically guided trans-esophageal echocardiography results in significantly fewer hypopharyngeal injuries and fewer contacts than traditional, blind transesophageal echocardiography. The optically guided technique may result in decreased frequency of potentially significant complications and therefore in improved patient safety.
Brase, Christoph; Schwitulla, Judith; Künzel, Julian; Meusel, Thomas; Iro, Heinrich; Hornung, Joachim
2013-12-01
To compare bone conduction after fiber-enabled CO2 laser perforation of the stapes footplate with conduction after the "one-shot" technique during stapedotomy in patients with otosclerosis. Retrospective clinical study. Tertiary reference center. We evaluated data from 178 patients who had undergone primary stapedotomy for suspected stapedial ankylosis. The stapes footplate was perforated using a fiber-enabled CO2 laser in 89 patients and the "one-shot" technique in the other 89. Only consecutive surgery was considered. Bone conduction thresholds were determined at 0.5, 1, 2, and 4 kHz on the first and third postoperative days in all patients; 172 patients were followed up after 1 month. Audiograms were compared with preoperative bone conduction. The postoperative bone conduction threshold on Day 1 was significantly worse at almost all frequencies. At 0.5 and 2 kHz, it improved within a month and was significantly different from the preoperative value. Bone conduction threshold at 4 kHz showed the greatest deterioration immediately after surgery, improving considerably in 1 month but remaining worse than at baseline. Only at 1 kHz was there no significant immediate hearing loss. Direct comparison of the fiber-enabled CO2 laser and the "one-shot" technique showed no statistically significant differences. Compared with the "one-shot" technique, the fiber-enabled CO2 laser can be used safely in stapes surgery, without great risk to the patient. In our opinion, it has practical advantages, especially in difficult anatomic conditions.
[Reconstruction of ankle and foot with combination of free perforator flaps and skin graft].
Yin, Lu; Gong, Ketong; Yin, Zhonggang; Zhang, Bo; Xu, Jianhua
2017-03-01
To evaluate the clinical outcomes of free perforator flaps combined with skin graft for reconstruction of ankle and foot soft tissue defects. Between June 2014 and October 2015, 20 cases of ankle and foot soft tissue defects were treated. There were 16 males and 4 females, aged from 19 to 61 years (mean, 43.3 years). Injury was caused by traffic accident in 7 cases, by crashing in 9 cases, and machine twist in 4 cases. The locations were the ankle in 6 cases, the heel in 3 cases, the dorsum pedis in 4 cases, and the plantar forefoot in 7 cases of avulsion injury after toes amputation. The size of wound ranged from 15 cm×10 cm to 27 cm×18 cm. The time from injury to treatment was from 11 to 52 days (mean, 27 days). The anterolateral thigh perforator flap was used in 11 cases, thoracodorsal antery perforator flap in 3 cases, medial sural artery perforator flap in 4 cases, deep inferior epigastric perforator flap in 1 case, and anteromedial thigh perforator flap in 1 case, including 5 chimeric perforator flaps, 5 polyfoliate perforator flaps, 3 flow-through perforator flaps, and 3 conjoined perforator flaps. The size of the perforator flap ranged from 10.0 cm×6.5 cm to 36.0 cm×8.0 cm, the size of skin graft from 5 cm×3 cm to 18 cm×12 cm. Venous crisis occurred in 2 flaps which survived after symptomatic treatment; 18 flaps survived successfully and skin grafting healed well. The follow-up time ranged 4-18 months (mean, 8.3 months). The flaps had good appearance, texture and color, without infection. The patients could walk normally and do daily activities. Only linear scars were observed at the donor sites. Free perforator flap can be used to reconstruct defects in the ankle and foot, especially in the weight-bearing area of the plantar forefoot. A combination of free perforator flap and skin graft is ideal in reconstruction of great soft tissue defects in the ankle and foot.
Damage Tolerant Repair Techniques for Pressurized Aircraft Fuselages
1994-01-01
2 if20 20 offset 50, fatigue GST, GLARE 2 if20 20 static, no fatigue *Unidirectional SP500 carbon/epoxy tape . "* Fatigue load did not initiate a crack...Et value, so this is a reasonable assumption. It further implies zero crack opening under the patch. The Erdogan solution [51 for two collinear...Cr Figure 6. 11. Idealization of patched crack as unfailed ligament between two collinear cracks (after [5, 6)). The Erdogan solution leads to the AK
Localized Patch Clamping of Plasma Membrane of a Polarized Plant Cell 1
Taylor, Alison R.; Brownlee, Colin
1992-01-01
We used an ultraviolet laser to rupture a small region of cell wall of a polarized Fucus spiralis rhizoid cell and gained localized access to the plasma membrane at the growing apex. Careful control of cell turgor enabled a small portion of plasma membrane-bound cytoplasm to be exposed. Gigaohm seals allowing single-channel recordings were obtained with a high success rate using this method with conventional patch clamp techniques. ImagesFigure 1 PMID:16669092
New Technique of Exposed Glaucoma Drainage Tube Repair: Report of a Case.
Berezina, Tamara L; Fechtner, Robert D; Cohen, Amir; Kim, Eliott E; Chu, David S
2015-01-01
We present the case of successful repair of an exposed glaucoma drainage tube by cornea graft fixation with tissue adhesive, and without subsequent coverage by adjacent conjunctiva or donor tissues. Patient with history of keratoglobus with thin cornea and sclera, and phthisical contralateral eye, underwent three unsuccessful corneal grafts followed by Boston type 1 keratoprosthesis in the right eye. Ahmed drainage device with sclera patch graft was implanted to control the intraocular pressure. Two years later the tube eroded through sclera graft and conjunctiva. Repair was performed by covering the tube with a corneal patch graft secured by tissue adhesive after the conjunctiva in this area was dissected away. The cornea graft was left uncovered due to fragility of adjacent conjunctiva. The healing of ocular and graft surfaces was complete prior to the 1 month follow-up. Conjunctival epithelium covered the corneal patch graft. At 12 months follow-up, the graft and the tube remained stable. Our report suggests that corneal patch graft fixation to the sclera by means of tissue adhesive, without closing the conjunctiva, can be considered as an effective alternative surgical approach for managing exposed glaucoma drainage tube, accompanied by adjacent conjunctiva tissue deficiency. How to cite this article: Berezina TL, Fechtner RD, Cohen A, Kim EE, Chu DS. New Technique of Exposed Glaucoma Drainage Tube Repair: Report of a Case. J Curr Glaucoma Pract 2015;9(2):62-64.
Hosseini, Seyed Nejat; Ammari, Ali; Mousavizadeh, Seyed Mehdi
2018-01-01
BACKGROUND Nowadays obesity is a common problem as it leads to abdominal deformation and people’s dissatisfaction of their own body. This study has explored using a new surgical technique based on a different incision to reform the flank skin laxity and dog ear plus aggressive liposuction on women with abdominal deformities. METHODS From May 2014 to February 2016, 25 women were chosen for this study. All women had a body mass index more than 28 kg/m2, flank folding, bulging and excess fat, abdominal and flank skin sagging and laxity. An important point of the new technique was that the paramedian perforator was preserved. RESULTS All women were between 33 and 62 years old (mean age of 47±7.2 years old). The average amount of liposuction aspirate was 2,350 mL (1700-3200 mL), and the size of average excised skin ellipse was 23.62×16.08 cm (from 19×15 to 27×18 cm). Dog ear, skin laxity, bulging and fat deposit correction were assessed and scored in two and four months after the surgery. CONCLUSION Aggressive abdominal and flank liposuction can be safely done when paramedian perforator is preserved. This has a good cosmetic result in the abdomen and flank and prevents bulging in the incision end and flank. Using this abdominoplasty technique is recommended on patients with high body mass indexes. PMID:29651396
Hosseini, Seyed Nejat; Ammari, Ali; Mousavizadeh, Seyed Mehdi
2018-01-01
Nowadays obesity is a common problem as it leads to abdominal deformation and people's dissatisfaction of their own body. This study has explored using a new surgical technique based on a different incision to reform the flank skin laxity and dog ear plus aggressive liposuction on women with abdominal deformities. From May 2014 to February 2016 , 25 women were chosen for this study. All women had a body mass index more than 28 kg/m 2 , flank folding, bulging and excess fat, abdominal and flank skin sagging and laxity. An important point of the new technique was that the paramedian perforator was preserved. All women were between 33 and 62 years old (mean age of 47±7.2 years old). The average amount of liposuction aspirate was 2,350 mL (1700-3200 mL), and the size of average excised skin ellipse was 23.62×16.08 cm (from 19×15 to 27×18 cm). Dog ear, skin laxity, bulging and fat deposit correction were assessed and scored in two and four months after the surgery. Aggressive abdominal and flank liposuction can be safely done when paramedian perforator is preserved. This has a good cosmetic result in the abdomen and flank and prevents bulging in the incision end and flank. Using this abdominoplasty technique is recommended on patients with high body mass indexes.