Clinical applications of perforator-based propeller flaps in upper limb soft tissue reconstruction.
Ono, Shimpei; Sebastin, Sandeep J; Yazaki, Naoya; Hyakusoku, Hiko; Chung, Kevin C
2011-05-01
A propeller flap is an island flap that moves from one orientation to another by rotating around its vascular axis. The vascular axis is stationary, and flap movement is achieved by revolving on this axis. Early propeller flaps relied on a thick, subcutaneous pedicle to maintain vascularity, and this limited the flap rotation to 90°. With increasing awareness of the location and the vascular territory perfused by cutaneous perforators, it is now possible to design propeller flaps based on a single perforator, so-called "perforator-based propeller flaps." These flaps permit flap rotation up to 180°. We present the results of upper limb soft tissue reconstruction using perforator-based propeller flaps. We constructed a treatment strategy based on the location of the soft tissue defect and the perforator anatomy for expedient wound coverage in 1 stage. All perforator-based propeller flaps derived from 3 institutions that were used for upper limb soft tissue reconstruction were retrospectively analyzed. The parameters studied included the size and location of the defect, the perforator that was used, the size and shape of the flap, the direction (ie, clockwise or counter-clockwise) of flap rotation, the degree of twisting of the perforator, the management of the donor site (ie, linear closure or skin grafting), and flap survival (recorded as the percentage of the flap area that survived). Twelve perforator-based propeller flaps were used to reconstruct upper limb soft tissue defects in 12 patients. Six different perforators were used as vascular pedicles. The donor defects of 11 flaps could be closed primarily. One flap was partially lost in a patient with electrical burns. Perforator-based propeller flaps provide a reliable option for covering small- to medium-size upper limb soft tissue defects. Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Kim, Youn Hwan; Kim, Sang Wha; Kim, Jeong Tae; Kim, Chang Yeon
2013-06-01
Tensor fascia lata (TFL) musculocutaneous flaps often require a donor site graft when harvesting a large flap. However, a major drawback is that it also sacrifices the muscle. To overcome this disadvantage, we designed a TFL perforator-based island flap that was harvested from a site near the defect and involved transposition within 90 degrees without full isolation of the pedicles. We performed procedures on 17 musculocutaneous flaps and 23 perforator-based island flaps, and compared the outcomes of these surgeries. The overall complication rate was 27.5% (11 regions). There were 7 complications related to the musculocutaneous flaps and 4 complications related to the perforator flaps. Although there were no statistical differences between those groups, lower complication rates were associated with procedures involving perforator flaps. The TFL perforator procedure is a simple and fast operation that avoids sacrificing muscle. This decreases complication rates compared to true perforator flap techniques that require dissection around the perforator or pedicle.
Porcine experimental model for perforator flap raising in reconstructive microsurgery.
González-García, José A; Chiesa-Estomba, Carlos M; Álvarez, Leire; Altuna, Xabier; García-Iza, Leire; Thomas, Izaskun; Sistiaga, Jon A; Larruscain, Ekhiñe
2018-07-01
Perforator free flap-based reconstruction of the head and neck is a challenging surgical procedure and needs a steep learning curve. A reproducible mammal large animal model with similarities to human anatomy is relevant for perforator flap raising and microanastomosis. The aim of this study was to assess the feasibility of a swine model for perforator-based free flaps in reconstructive microsurgery. Eleven procedures were performed under general anesthesia in a porcine model, elevating a skin flap vascularized by perforating musculocutaneous branches of the superior epigastric artery to evaluate the relevance of this model for head and neck reconstructive microsurgery. The anterior abdominal skin perforator-based free flap in a swine model irrigated by the superior epigastric artery was elevated in eleven procedures. In six of these procedures, we could perform an arterial and venous microanastomosis to the great vessels located in the base of the neck. The porcine experimental model of superior epigastric artery perforator-based free flap reconstruction offers relevant similarities to the human deep inferior epigastric artery perforator flap. We could demonstrate this model as acceptable for perforator free flap training due to the necessity of perforator and pedicle dissection and transfer to a distant area. Copyright © 2018 Elsevier Inc. All rights reserved.
Chaput, B; Gandolfi, S; Ho Quoc, C; Chavoin, J-P; Garrido, I; Grolleau, J-L
2014-02-01
In recent years, perforator flaps have become an indispensable tool for the reconstruction process. Most recently, "propeller" perforator flaps allow each perforator vessels to become a flap donor site. Once the perforator of interest is identified by acoustic Doppler, the cutaneous or fascio-cutaneous island is designed and then customized according to the principle of "perforasome". So, the flap can be rotated such a propeller, up to 180°. Ideally the donor site is self-closing, otherwise it can be grafted at the same time. Through a skin necrosis secondary to a contrast medium extravasation of the cubital fossa in a 47-year-old man, we describe the use of propeller perforator flap based on a perforator of the radial collateral artery (RCAP). The perforator was identified preoperatively by acoustic Doppler then the flap was adapted bespoke to cover the loss of substance. Ultimately, the result was very satisfying. Well experienced for lower-extremity reconstruction, perforator-based propeller flap are still few reported for upper limb. It is likely that in the future, propeller flap supersede in many indication not only free flaps and locoregional flaps but also, leaving no room for uncertainties of the vascular network, the classic random flaps. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Parasacral Perforator Flaps for Reconstruction of Sacral Pressure Sores.
Lin, Chin-Ta; Chen, Shih-Yi; Chen, Shyi-Gen; Tzeng, Yuan-Sheng; Chang, Shun-Cheng
2015-07-01
Despite advances in reconstruction techniques, pressure sores continue to present a challenge to the plastic surgeon. The parasacral perforator flap is a reliable flap that preserves the entire contralateral side as a future donor site. On the ipsilateral side, the gluteal muscle itself is preserved and all flaps based on the inferior gluteal artery are still possible. We present our experience of using parasacral perforator flaps in reconstructing sacral defects. Between August 2004 and January 2013, 19 patients with sacral defects were included in this study. All the patients had undergone surgical reconstruction of sacral defects with a parasacral perforator flap. The patients' sex, age, cause of sacral defect, flap size, flap type, numbers of perforators used, rotation angle, postoperative complications, and hospital stay were recorded. There were 19 parasacral perforator flaps in this series. All flaps survived uneventfully except for 1 parasacral perforator flap, which failed because of methicillin-resistant Staphylococcus aureus infection. The overall flap survival rate was 95% (18/19). The mean follow-up period was 17.3 months (range, 2-24 months). The average length of hospital stay was 20.7 days (range, 9-48 days). No flap surgery-related mortality was found. Also, there was no recurrence of sacral pressure sores or infected pilonidal cysts during the follow-up period. Perforator-based flaps have become popular in modern reconstructive surgery because of low donor-site morbidity and good preservation of muscle. Parasacral perforator flaps are durable and reliable in reconstructing sacral defects. We recommend the parasacral perforator flap as a good choice for reconstructing sacral defects.
A Novel Perforator Flap Training Model Using a Chicken Leg.
Cifuentes, Ignacio J; Yañez, Ricardo A; Salisbury, Maria C; Rodriguez, José R; Varas, Julian E; Dagnino, Bruno L
2016-04-01
Living animal models are frequently used for perforator flap dissection training, but no ex vivo models have been described. The aim of this study is to present a novel nonliving model for perforator flap training based on a constant perforator in the chicken leg. A total of 15 chicken legs were used in this study. Anatomical dissection of the perforator was performed after its identification using ink injection, and in four of these specimens a perforator-based flap was raised. The anatomical dissection revealed a constant intramuscular perforator with a median length of 5.7 cm. Median proximal and distal vessel diameters were 0.93 and 0.4 mm, respectively. The median dissection time was 77.5 minutes. This study introduces a novel, affordable, and reproducible model for the intramuscular dissection of a perforator-based flap using an ex vivo animal model. Its consistent perforator and appropriate-sized vessels make it useful for training.
Free style perforator based propeller flaps: Simple solutions for upper extremity reconstruction!
Panse, Nikhil; Sahasrabudhe, Parag
2014-01-01
The introduction of perforator flaps by Koshima et al. was met with much animosity in the plastic surgery fraternity. The safety concerns of these flaps following the intentional twist of the perforators have prevented widespread adoption of this technique. Use of perforator based propeller flaps in the lower extremity is gradually on the rise, but their use in upper extremity reconstruction is infrequently reported, especially in the Indian subcontinent. We present a retrospective series of 63 free style perforator flaps used for soft tissue reconstruction of the upper extremity from November 2008 to June 2013. Flaps were performed by a single surgeon for various locations and indications over the upper extremity. Patient demographics, surgical indication, defect features, complications and clinical outcome are evaluated and presented as an uncontrolled case series. 63 free style perforator based propeller flaps were used for soft tissue reconstruction of 62 patients for the upper extremity from November 2008 to June 2013. Of the 63 flaps, 31 flaps were performed for trauma, 30 for post burn sequel, and two for post snake bite defects. We encountered flap necrosis in 8 flaps, of which there was complete necrosis in 4 flaps, and partial necrosis in four flaps. Of these 8 flaps, 7 needed a secondary procedure, and one healed secondarily. Although we had a failure rate of 12-13%, most of our failures were in the early part of the series indicative of a learning curve associated with the flap. Free style perforator based propeller flaps are a reliable option for coverage of small to moderate sized defects. Therapeutic IV.
Scaglioni, Mario F; Barth, Andrè A; Chen, Yen-Chou
2018-06-19
The primary closure of the vertical posteromedial thigh (vPMT) free flap donor site is very important to minimize donor site morbidity and maximize cosmetic appearance. However, sometimes due to the dimension of the defect, a vPMT flap is wider than the 8-10 cm requirement. The authors report their experience with the third perforator of the profunda femoris artery (PFA) during the vPMT free flap donor-site closure. Between January 2016 and December 2017, 5 patients underwent reconstruction of lower extremity (2 pts.) and head and neck (3 pts.) area with the free vPMT flaps. Attempts to close the vPMT free flap donor site directly failed due to the flaps' width (average: 11 cm) and pedicled perforator flaps based on the third perforator of the PFA at the distal thigh were harvested to close the defect primary without the use of a skin graft. The size of perforator flap based on 3rd perforator of PFA was on average 6 cm × 4 cm (ranged: 4-8 cm × 3-6 cm). In all patients, the third perforator of the PFA was identified and the perforator diameter was on average 2.0 mm (range, 1.8-2.2 mm). All perforators were musculocutaneous and single. The dimensions of the flaps were on average 6 cm × 4 cm (range: 4 to 8 cm × 3 to 6 cm). All flaps healed uneventfully without complications and the patients were satisfied with cosmetic and functional results at 6 months follow-up. The third perforator of the PFA may be an option to ensure primary closure of the PMT flap donor site, when a larger flap for reconstruction is needed with subsequent impossibility to achieve primary closure of the donor site. © 2018 Wiley Periodicals, Inc.
Reconstruction of pressure sores with perforator-based propeller flaps.
Jakubietz, Rafael G; Jakubietz, Danni F; Zahn, Robert; Schmidt, Karsten; Meffert, Rainer H; Jakubietz, Michael G
2011-03-01
Perforator flaps have been successfully used for reconstruction of pressure sores. Although V-Y advancement flaps approximate debrided wound edges, perforator-based propeller flaps allow rotation of healthy tissue into the defect. Perforator-based propeller flaps were planned in 13 patients. Seven pressure sores were over the sacrum, five over the ischial tuberosity, and one on the tip of the scapula. Three patients were paraplegic, six were bedridden, and five were ambulatory. In three patients, no perforators were found. In 10 patients, propeller flaps were transferred. In two patients, total flap necrosis occurred, which was reconstructed with local advancement flaps. In two cases, a wound dehiscence occurred and had to be revised. One hematoma required evacuation. No further complications were noted. No recurrence at the flap site occurred. Local perforator flaps allow closure of pressure sores without harvesting muscle. The propeller version has the added benefit of transferring tissue from a distant site, avoiding reapproximation of original wound edges. Twisting of the pedicle may cause torsion and venous obstruction. This can be avoided by dissecting a pedicle of at least 3 cm. Propeller flaps are a safe option for soft tissue reconstruction of pressure sores. © Thieme Medical Publishers.
A Novel Perforator Flap Training Model Using a Chicken Leg
Cifuentes, Ignacio J.; Yañez, Ricardo A.; Salisbury, Maria C.; Rodriguez, José R.; Varas, Julian E.; Dagnino, Bruno L.
2016-01-01
Introduction Living animal models are frequently used for perforator flap dissection training, but no ex vivo models have been described. The aim of this study is to present a novel nonliving model for perforator flap training based on a constant perforator in the chicken leg. Methods A total of 15 chicken legs were used in this study. Anatomical dissection of the perforator was performed after its identification using ink injection, and in four of these specimens a perforator-based flap was raised. Results The anatomical dissection revealed a constant intramuscular perforator with a median length of 5.7 cm. Median proximal and distal vessel diameters were 0.93 and 0.4 mm, respectively. The median dissection time was 77.5 minutes. Conclusion This study introduces a novel, affordable, and reproducible model for the intramuscular dissection of a perforator-based flap using an ex vivo animal model. Its consistent perforator and appropriate-sized vessels make it useful for training. PMID:27616823
Saçak, Bülent; Yalçın, Doğuş; Pilancı, Özgür; Tuncer, Fatma Betül; Çelebiler, Özhan
2017-01-01
Background The effect of liposuction on the perforators of the lower abdominal wall has been investigated in several studies. There are controversial results in the literature that have primarily demonstrated the number and patency of the perforators. The aim of this study was to determine the effect of liposuction on the perfusion of perforator-based abdominal flaps using a combined laser–Doppler spectrophotometer (O2C, Oxygen to See, LEA Medizintechnik). Methods Nine female patients undergoing classical abdominoplasty were included in the study. Perforators and the perfusion zones of the deep inferior epigastric artery flap were marked on the patient's abdominal wall. Flap perfusion was quantitatively assessed by measuring blood flow, velocity, capillary oxygen saturation, and relative amount of hemoglobin for each zone preoperatively, after tumescent solution infiltration, following elevation of the flap on a single perforator, and after deep and superficial liposuction, respectively. Results The measurements taken after elevation of the flap were not significantly different than measurements taken after the liposuction procedures. Conclusions The liposuction procedure does not significantly alter the perfusion of perforator-based abdominal flaps in the early period. The abdominal tissue discarded in a classic abdominoplasty operation can be raised as a perforator flap and has been demonstrated to be a unique model for clinical research. PMID:28352599
Reconstruction of Anterolateral Thigh Defects Using Perforator-Based Propeller Flaps.
Iida, Takuya; Yoshimatsu, Hidehiko; Koshima, Isao
2017-10-01
Usually, anterolateral thigh (ALT) defects with width more than 8 cm cannot be closed directly. Although several methods of using local flaps exist, flap mobility of these methods is limited. We introduced a perforator-based propeller flap for such reconstruction. Their maximal mobility, which minimizes their size, is their greatest advantage. In addition, we present our technical refinements including double-axes propeller flap, the use of indocyanine green real-time angiography, and supercharged propeller flap for safer flap transfer. Seven patients underwent perforator-based propeller flap reconstruction of ALT defects. Flaps were designed cranial or caudal to the defect according to the perforator locations. To maximize mobility, flaps were designed so that the perforator was located at the periphery and closer to the defect. After rotating the flap to the defect, indocyanine green angiography was performed to determine the need for supercharge. In all cases, all flaps survived completely. Defect size ranged from 12 × 11 cm to 18 × 16 cm, and flap size ranged from 7 × 5 cm to 15 × 7 cm. The number of perforators in the flap was 1 in 3 cases and 2 in 4 cases. Supercharging was performed in 3 cases. Donor-site complications, including gait disturbance, were not observed. This method achieves ALT defect closure with minimal donor-site morbidity and can provide prompt and aesthetically acceptable results. Indocyanine green real-time angiography and supercharging technique are also useful for safer and reliable flap transfer.
Giant trochanteric pressure sore: Use of a pedicled chimeric perforator flap for cover
Mehrotra, Sandeep
2009-01-01
Pressure sores are increasing in frequency commensurate with an ageing population with multi-system disorders and trauma. Numerous classic options are described for providing stable wound cover. With the burgeoning knowledge on perforator anatomy, recent approaches focus on the use of perforator-based flaps in bedsore surgery. A giant neglected trochanteric pressure sore in a paraplegic is presented. Since conventional options of reconstruction appeared remote, the massive ulcer was successfully managed by a chimeric perforator-based flap. The combined muscle and fasciocutaneous flaps were raised as separate paddles based on the anterolateral thigh perforator branches and provided stable cover without complications. Perforators allow versatility in managing complex wounds without compromising on established principles. PMID:19881035
Kim, Jeong Tae; Kim, Youn Hwan; Ghanem, Ali M
2015-11-01
Complex defects present structural and functional challenges to reconstructive surgeons. When compared to multiple free flaps or staged reconstruction, the use of chimeric flaps to reconstruct such defects have many advantages such as reduced number of operative procedures and donor site morbidity as well as preservation of recipient vessels. With increased popularity of perforator flaps, chimeric flaps' harvest and design has benefited from 'perforator concept' towards more versatile and better reconstruction solutions. This article discusses perforator based chimeric flaps and presents a practice based classification system that incorporates the perforator flap concept into "Perforator Chimerism". The authors analyzed a variety of chimeric patterns used in 31 consecutive cases to present illustrative case series and their new classification system. Accordingly, chimeric flaps are classified into four types. Type I: Classical Chimerism, Type II: Anastomotic Chimerism, Type III: Perforator Chimerism and Type IV Mixed Chimerism. Types I on specific source vessel anatomy whilst Type II requires microvascular anastomosis to create the chimeric reconstructive solution. Type III chimeric flaps utilizes the perforator concept to raise two components of tissues without microvascular anastomosis between them. Type IV chimeric flaps are mixed type flaps comprising any combination of Types I to III. Incorporation of the perforator concept in planning and designing chimeric flaps has allowed safe, effective and aesthetically superior reconstruction of complex defects. The new classification system aids reconstructive surgeons and trainees to understand chimeric flaps design, facilitating effective incorporation of this important reconstructive technique into the armamentarium of the reconstruction toolbox. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Sameem, Mojib; Au, Michael; Wood, Thomas; Farrokhyar, Forough; Mahoney, James
2012-07-01
Management of pressure sores poses a significant reconstructive challenge for plastic surgeons. Currently, there is no consensus on whether musculocutaneous, fasciocutaneous, or perforator-based flaps provide superior results for treating pressure sores. The following databases were searched: Cochrane Database of Systematic Reviews, Cochrane Central Register of Controlled Trials, LILACS (January of 1950 to November of 2010), MEDLINE (January of 1950 to November of 2010), and EMBASE (January of 1980 to November of 2010). Only articles reporting on the use of musculocutaneous, fasciocutaneous, and perforator-based flaps were included. The primary study outcomes were complication and recurrence rates. Fifty-five articles were included in the final analysis (kappa = 0.78). From this total, 28 were categorized as pertaining to musculocutaneous flaps, 13 studied fasciocutaneous flaps, and 14 evaluated perforator-based flaps. The authors' review revealed recurrence and complication rates of 8.9 and 18.6 percent, respectively, following reconstruction with musculocutaneous flaps, 11.2 and 11.7 percent following reconstruction with fasciocutaneous flaps, and 5.6 and 19.6 percent following reconstruction with perforator-based flaps. Overall, statistical analysis revealed no significant difference in complication or recurrence rates among these three techniques. The authors' review revealed that there was no statistically significant difference with regard to recurrence or complication rates among musculocutaneous, fasciocutaneous, or perforator-based flaps. This suggests that surgeons performing such reconstructive procedures may choose to consider the advantages of a specific approach rather than the complication and recurrence rates. Therapeutic, IV.
Preoperative color Doppler assessment in planning of gluteal perforator flaps.
Isken, Tonguc; Alagoz, M Sahin; Onyedi, Murat; Izmirli, Hakki; Isil, Eda; Yurtseven, Nagehan
2009-02-01
Gluteal artery perforator flaps have gained popularity due to reliability, preservation of the muscle, versatility in flap design without restricting other flap options, and low donor-site morbidity in ambulatory patients and possibility of enabling future reconstruction in paraplegic patients. But the inconstant anatomy of the vascular plexus around the gluteal muscle makes it hard to predict how many perforators are present, what their volume of blood flow and size are, where they exit the overlying fascia, and what their course through the muscle will be. Without any prior investigations, the reconstructive surgeon could be surprised intraoperatively by previous surgical damage, scar formation, or anatomic variants.For these reasons, to confirm the presence and the location of gluteal perforators preoperatively we have used color Doppler ultrasonography. With the help of the color Doppler ultrasonography 26 patients, 21 men and 5 women, were operated between the years 2002 and 2007. The mean age of patients was 47.7 (age range: 7-77 years). All perforator vessels were marked preoperatively around the defect locations. The perforator based flap that will allow primary closure of the donor site and the defect without tension was planned choosing the perforator that showed the largest flow in color Doppler ultrasonography proximally. Perforators were found in the sites identified with color Doppler ultrasonography in all other flaps. In our study, 94.4% flap viability was ensured in 36 perforator-based gluteal area flaps. Mean flap elevation time was 31.9 minutes. We found that locating the perforators preoperatively helps to shorten the operation time without compromising a reliable viability of the perforator flaps, thus enabling the surgeon easier treatment of pressure sores.
Chi, Zhenglin; Chen, Yiheng; Chu, Tinggang; Gao, Weiyang; Li, Zhijie; Yan, Hede; Song, Yonghuan
2018-02-01
The conventional procedure of the sural neuro-fasciocutaneous flap enables the supply of blood and venous drainage by increasing the width of the adipofascial tissue and preserving tiny venous return routes. Moreover, skin graft is a common method for donor site closure, which may lead to some complications and influence the aesthetic appearance. We report modifications for a distally based sural neuro-fasciocutaneous perforator flap and a relaying flap for donor site closure without skin graft. Twelve patients undergoing the modified flap for foot and ankle reconstruction were included in this study between 2014 and 2016. A peroneal-based perforator, a superficial vein, and the vascular axis of the sural nerve were included in the pedicle. A Z-shape skin incision was performed to explore the perforator vessels and a relaying island perforator flap was used to close the donor site. All flaps survived completely without necrosis. The area of the flaps ranged from 16 × 8 cm to 30 × 15 cm. The diameter width of the pedicle ranged from 1.0 to 2.0 cm. A relaying perforator island flap was used in 10 cases for donor site closure and no skin graft was performed. There were no serious donor site complications. All patients were satisfied with the aesthetic outcome postoperatively at the final follow-up. The distally based sural neuro-fasciocutaneous perforator flap is considered a reliable method for foot and ankle reconstruction. The modification for flap pedicle and donor site closure method without skin graft should be recommended. Copyright © 2017. Published by Elsevier Ltd.
Han, Ba Leun; Choi, Hwan Jun
2014-03-01
Sequential flap coverage might be required for recurrent defects, but reusing a flap as a donor site has seldom been reported. The concept of a "free-style flap" has been developed, and it allows reconstructive surgeons to raise flaps with various designs reliably, even at sites of previous flap surgery. This article presents the concept of free-style recycling of a tensor fascia lata flap into a perforator-based flap separated in 2 planes in a patient with a recurrent bilateral trochanteric defect. If a reliable perforator is preserved and identified within the tissues by computed tomography angiography or a Doppler device, a new perforator flap can be designed and raised at the previous flap site.
The Utility and Versatility of Perforator-Based Propeller Flaps in Burn Care.
Teven, Chad M; Mhlaba, Julie; O'Connor, Annemarie; Gottlieb, Lawrence J
The majority of surgical burn care involves the use of skin grafts. However, there are cases when flaps are required or provide superior outcomes both in the acute setting and for postburn reconstruction. Rarely discussed in the context of burn care, the perforator-based propeller flap is an important option to consider. We describe our experience with perforator-based propeller flaps in the acute and reconstructive phases of burn care. We reviewed demographics, indications, operative details, and outcomes for patients whose burn care included the use of a perforator-based propeller flap at our institution from May 2007 to April 2015. Details of the surgical technique and individual cases are also discussed. Twenty-one perforator-based propeller flaps were used in the care of 17 burn patients. Six flaps (29%) were used in the acute phase for coverage of exposed joints, tendons, cartilage, and bone; coverage of open wounds; and preservation of range of motion (ROM) by minimizing scar contracture. Fifteen flaps (71%) were used for reconstruction of postburn deformities including coverage of chronic wounds, for coverage after scar contracture release, and to improve ROM. The majority of flaps (94% at follow-up) exhibited stable soft tissue coverage and good or improved ROM of adjacent joints. Three cases of partial flap loss and one case of total flap loss occurred. Perforator-based propeller flaps provide reliable vascularized soft tissue for coverage of vital structures and wounds, contracture release, and preservation of ROM across joints. Despite a relatively significant risk of minor complications particularly in the coverage of chronic wounds, our study supports their utility in both the acute and reconstructive phases of burn care.
Perforator-based island flap with a peripheral muscle patch for coverage of sacral sores.
Chang, Jung Woo; Lee, Jang Hyun; Choi, Matthew Seung Suk
2016-06-01
Despite numerous therapeutic advances, the treatment of pressure sores remains a challenge. The increased use of perforator flaps enables surgeons to minimize donor-site morbidity by sparing the underlying muscle. In the presence of focal deep spaces, however, the inclusion of muscle would be beneficial. The goal of this study was to introduce a method for including a muscle patch at the periphery of a perforator-based island flap for coverage of sacral pressure sores. Between March 2010 and February 2015, 26 patients with stage IV sacral sores underwent perforator-based island flap reconstruction with a peripheral muscle patch. Patient characteristics, including sex, age, defect size, and postoperative complications, were recorded. All flaps survived without major complications. No flap necrosis was noted. The present study shows that a muscle patch incorporated into the periphery of a perforator-based flap can be transferred safely. This can be a good surgical option in cases where infection control or more volume is needed. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Yu, Shengji; Zang, Mengqing; Xu, Libin; Zhao, Zhenguo; Zhang, Xinxin; Zhu, Shan; Chen, Bo; Ding, Qiang; Liu, Yuanbo
2016-10-01
Defects after soft tissue sarcoma resection are usually managed by myocutaneous flaps or free flaps. However, harvesting muscle will cause functional morbidities, and some regions lack reliable recipient vessel. Our purpose is to use various perforator propeller flaps for oncologic reconstruction. Between 2008 and 2014, 33 perforator propeller flaps were performed in 24 patients to reconstruct the defects after tumor resection in trunk and extremities. Fifteen patients underwent tumor resection previously. Thirteen patients underwent adjuvant radiotherapy or chemotherapy. Flaps based on perforators adjacent to the lesions were raised and rotated in propeller fashion to repair the defects. Twenty-seven flaps were based on perforators of known source vessels, and 6 were harvested in freestyle fashion. The defects were repaired with 2 flaps in 4 patients and 3 flaps in 2 patients. The mean skin paddle dimension was 8.36 cm in width and 20.42 cm in length. The mean degree of flap rotation was 158.79°. Complications include partial necrosis of 6 flaps in 5 cases and venous congestion of 1 flap. In these 6 patients, 3 underwent adjuvant radiotherapy. The donor sites were primarily closed in 21 patients and skin grafted in 3 patients. No functional loss related to flap harvesting was recognized. The perforator propeller flaps can be used to manage the medium defects in extremities and large defects in torso after soft tissue sarcoma resection. They avoid the sacrifice of the underlying muscle and eliminate the concerns of the unavailability of recipient vessels. The perforator propeller flaps provide flexible options for versatile oncologic reconstruction in trunk and extremities. However, the impact of radiotherapy on the viability of the flaps for local reconstruction needs further investigation.
A simple concept for covering pressure sores: wound edge-based propeller perforator flap.
Kelahmetoglu, Osman; Van Landuyt, Koenraad; Yagmur, Caglayan; Sommeling, Casper E; Keles, Musa K; Tayfur, Volkan; Simsek, Tekin; Demirtas, Yener; Guneren, Ethem
2017-12-01
We present a new surgical modification to allow propeller perforator flaps to cover pressure sores at various locations. We used a propeller perforator flap concept based on the detection of newly formed perforator vessels located 1 cm from the wound margin and stimulated by the chronic inflammation process. Between January 2009 and January 2017, 33 wound edge-based propeller perforator flaps were used to cover pressure sores at various locations in 28 patients. In four cases more than one flap was used on the same patient. The patients comprised 18 males and 10 females with a mean age of 41·25 (range, 16-70) years. All patients underwent follow-up for 0-12 months. The mean follow-up duration was 5·03 months. Venous congestion was observed in three flaps that were rotated by 180° (9·1%). However, there was a significant difference between flaps rotated by 90° and 180° according to the complication rate (P = 0·034). Out of 33 flaps, 29 flaps healed uneventfully. Patients were able to sit and lie on their flaps three weeks after surgery. In our study, we were able to obtain satisfying final results using these novel flaps. © 2017 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Paramuscular perforators in DIEAP flap for breast reconstruction.
Pons, Gemma; Masia, Jaume; Sanchez-Porro, Lídia; Larrañaga, Jose; Clavero, Juan Angel
2014-12-01
One of the main steps in perforator flap surgery is to identify the dominant perforator. Using multidetector row computed tomography (MDCT) for the preoperative planning of deep inferior epigastric artery perforator (DIEAP) flap surgery, we identified a perforator with a large caliber, an excellent location in the middle abdominal region, and a totally extramuscular trajectory in a significant number of patients. We describe the frequency of this perforator and determine its characteristics. We conducted a retrospective study of 482 patients who underwent 526 DIEAP flaps for breast reconstruction from October 2003 to October 2011. Mean age at surgery was 51.3 years old. A preoperative MDCT of abdominal vascularization was performed in all patients. MDCT identified a dominant perforator with a paramuscular course in 12.4% of abdominal walls. In all cases, it was located in the midline and emerged directly from the deep inferior epigastric system. Its mean caliber was 1.9 mm. The flap was harvested based on this perforator in all these patients, and mean harvest time was 51 minutes. The characteristics of this perforator made dissection easier and reduced morbidity at the donor site. There were no flap losses and the only complications were minor. We located a paramuscular perforator in 12.4% of patients undergoing breast reconstruction with abdominal perforator flaps. Its morphological features and extramuscular course make it the perforator of choice in DIEAP flap surgery.
Onishi, Tadanobu; Shimizu, Takamasa; Omokawa, Shohei; Sananpanich, Kanit; Kido, Akira; Mahakkanukrauh, Pasuk; Tanaka, Yasuhito
2018-05-30
There is lack of anatomical information regarding cutaneous perforator of the popliteal artery and its connections with the descending branch of the inferior gluteal and profunda femoris arteries. We aimed to evaluate the anatomical basis of popliteal artery perforator-based propeller flap from the posterior thigh region and to demonstrate our experience utilizing this flap. Ten fresh cadaveric lower extremities were dissected following injection of a silicone compound into the femoral artery. We investigated the number, location, length, and diameter of cutaneous perforators of the popliteal artery. Based on the results, we treated three cases with a large soft tissue defect around the knee using popliteal artery perforator-based propeller flap. We found a mean of 1.9 cutaneous perforators arising from the popliteal artery with a mean pedicle length of 6 cm and a mean arterial internal diameter of 0.9 mm, which were located at an average of 4 cm proximal to the bicondylar line. The most distal perforator consistently arose along the small saphenous vein and connected proximally with concomitant artery of the posterior femoral cutaneous nerve, forming a connection with perforating arteries of the profunda femoris artery. A mean of 4.5 cutaneous perforators branched from the arterial connection sites. All clinical cases healed without any complications. The popliteal artery perforator-based propeller flap is reliable for reconstruction of soft tissue defects around the knee. The flap should include the deep fascia and concomitant artery along with the posterior femoral cutaneous nerve for maintaining the blood supply.
Vitse, J; Bekara, F; Bertheuil, N; Sinna, R; Chaput, B; Herlin, C
2017-02-01
Current data on upper extremity propeller flaps are poor and do not allow the assessment of the safety of this technique. A systematic literature review was conducted searching PubMed, EMBASE, and the Cochrane Library electronic databases, and the selection process was adapted from the preferred reporting items for systematic reviews and meta-analysis statement. The final analysis included ten relevant articles involving 117 flaps. The majority of flaps were used for the hand, distal wrist, and elbow. The radial artery perforator and ulnar artery perforator were the most frequently used flaps. The were 7% flaps with venous congestion and 3% with complete necrosis. No difference in complications rate was found for different flaps sites. Perforator-based propeller flaps appear to be an interesting procedure for covering soft tissue defects involving the upper extremities, even for large defects, but the procedure requires experience and close monitoring. II.
Calf Perforator Flaps: A Freestyle Solution for Oral Cavity Reconstruction.
Molina, Alexandra R; Citron, Isabelle; Chinaka, Fungayi; Cascarini, Luke; Townley, William A
2017-02-01
Reconstruction of oral cavity defects requires a thin, pliable flap for optimal functional results. Traditional flap choices are imperfect: the anterolateral thigh flap is excessively thick, whereas the radial forearm flap has a poor donor site. The authors therefore favor calf perforator flaps such as the medial sural artery perforator flap to provide thin tissue with an acceptable donor site. This two-part study aims to demonstrate their suitability for intraoral reconstruction. In the radiologic part of the study, the authors compared thigh and calf tissue thickness by examining lower limb computed tomographic scans of 100 legs. For their clinical study, they collected data prospectively on 20 cases of oral cavity reconstruction using calf perforator flaps. The mean thickness of the calf tissue envelope was significantly less than that of the thigh (8.4 mm compared with 17 mm) based on computed tomographic analysis. In the clinical study, a medial sural artery perforator was used in the majority of cases (17 of 20). The mean pedicle length was 10.2 cm and the mean time to raise a flap was 85 minutes. There were no flap losses. One patient was returned to the operating room for management of late hematoma and wound dehiscence. Calf perforator flaps provide ideal tissue for intraoral reconstruction and are significantly thinner than anterolateral thigh flaps. In addition to medial sural artery perforator flaps, the authors raised both sural and soleal artery perforator flaps in this series. Opportunistic use of the calf donor site allows the harvest of thin tissue with minimal donor-site morbidity. Therapeutic, IV.
Lin, Pao-Yuan; Kuo, Yur-Ren; Tsai, Yun-Ta
2012-03-01
Perforator-based fasciocutaneous flaps for reconstructing pressure sores can achieve good functional results with acceptable donor site complications in the short-term. Recurrence is a difficult issue and a major concern in plastic surgery. In this study, we introduce a reusable perforator-preserving gluteal artery-based rotation flap for reconstruction of pressure sores, which can be also elevated from the same incision to accommodate pressure sore recurrence. The study included 23 men and 13 women with a mean age of 59.3 (range 24-89) years. There were 24 sacral ulcers, 11 ischial ulcers, and one trochanteric ulcer. The defects ranged in size from 4 × 3 to 12 × 10 cm(2) . Thirty-six consecutive pressure sore patients underwent gluteal artery-based rotation flap reconstruction. An inferior gluteal artery-based rotation fasciocutaneous flap was raised, and the superior gluteal artery perforator was preserved in sacral sores; alternatively, a superior gluteal artery-based rotation fasciocutaneous flap was elevated, and the inferior gluteal artery perforator was identified and dissected in ischial ulcers. The mean follow-up was 20.8 (range 0-30) months in this study. Complications included four cases of tip necrosis, three wound dehiscences, two recurrences reusing the same flap for pressure sore reconstruction, one seroma, and one patient who died on the fourth postoperative day. The complication rate was 20.8% for sacral ulcers, 54.5% for ischial wounds, and none for trochanteric ulcer. After secondary repair and reconstruction of the compromised wounds, all of the wounds healed uneventfully. The perforator-preserving gluteal artery-based rotation fasciocutaneous flap is a reliable, reusable flap that provides rich vascularity facilitating wound healing and accommodating the difficulties of pressure sore reconstruction. Copyright © 2011 Wiley Periodicals, Inc.
Zhang, Fahui; Xie, Qiyang; Zheng, Heping
2005-07-01
To investigate the distribution of the perforating branches artery of distally-based flap of sural nerve nutrient vessels and its clinical application. The origins and distribution of perforating branches artery of distally-based flap were observed on specimens of 30 adult cadaveric low limbs by perfusing red gelatin to dissect the artery. Among the 36 cases, there were 21 males, 15 females. Their ages ranged from 6 to 66, 35. 2 in average. The defect area was 3.5 cm x 2.5 cm to 17.0 cm x 11.0 cm. The flap taken ranged from 4 cm x 3 cm to 18 cm x 12 cm. The perforating branches artery of distally-based flap had 2 to 5 branches and originated from the heel lateral artery, the terminal perforating branches of peroneal artery (diameters were 0.6+/-0.2 mm and 0.8+/-0.2 mm, 1.0 +/- 1.3 cm and 2.8 +/- 1.0 cm to the level of cusp lateral malleolus cusp). The intermuscular septum perforating branches of peroneal artery had 0 to 3 branches. Their rate of presence was 96.7%, 66.7% and 20.0% respectively (the diameters were 0.9 +/- 0.3, 1.0 +/- 0.2 and 0.8 +/- 0.4 mm, and their distances to the level of cusp of lateral malleolus were 5.3 +/- 2.1, 6.8 +/- 2.8 and 7.0 +/- 4.0 cm). Those perforating branches included fascia branches, cutaneous branches, nerve and vein nutrient branches. Those nutrient vessels formed longitudinal vessel chain of sural nerve shaft, vessel chain of vein side and vessel network of deep superficial fascia. The distally-based superficial sural artery island flap was used in 18 cases, all flaps survived. Distally-based sural nerve, small saphenous vein, and nutrient vessels of fascia skin have the same origin. Rotation point of flap is 3.0 cm to the cusp of lateral malleolus, when the distally-based flap is pedicled with the terminal branch of peroneal artery. Rotation point of flap is close to the cusp of lateral malleolus, when the distally-based flap is pedicled with the heel lateral artery.
Liu, Yiyang; Zhang, Chun; Guo, Qiaofeng; Huang, Wenhua; Wong, Kelvin Kian Loong; Chang, Shimin
2017-01-01
Objective To describe the characteristics of the perforator vessel in the peroneal artery of the lower leg and to explore the use of perforator pedicle propeller flaps to repair soft tissue defects in the lower leg, heel and foot. Methods This retrospective study enrolled patients with soft tissue defects of the distal lower leg, heel and foot who underwent surgery using peroneal perforator-based propeller flaps. The peroneal artery perforators were identified preoperatively by colour duplex Doppler ultrasound. The flap was designed based on the preoperatively-identified perforator location, with the posterior border of the fibula employed as an axis, and the perforator vessel as the pivot point of rotation. Patients were followed-up to determine the outcomes. Results The study analysed 36 patients (mean age, 39.7 years). The majority of the soft tissue defects were on the heel (20; 55.6%). The donor-site of the flap was closed in 11 patients by direct suturing and skin grafting was undertaken in 25 patients. Postoperative complications included venous congestion (nine patients), which was managed with delayed wound coverage and bleeding therapy. All wounds were eventually cured and the flaps were cosmetically acceptable. Conclusions The peroneal perforator pedicle propeller flap is an appropriate choice to repair soft tissue defects of the distal limbs. PMID:28345420
Shen, Lifeng; Liu, Yiyang; Zhang, Chun; Guo, Qiaofeng; Huang, Wenhua; Wong, Kelvin Kian Loong; Chang, Shimin
2017-06-01
Objective To describe the characteristics of the perforator vessel in the peroneal artery of the lower leg and to explore the use of perforator pedicle propeller flaps to repair soft tissue defects in the lower leg, heel and foot. Methods This retrospective study enrolled patients with soft tissue defects of the distal lower leg, heel and foot who underwent surgery using peroneal perforator-based propeller flaps. The peroneal artery perforators were identified preoperatively by colour duplex Doppler ultrasound. The flap was designed based on the preoperatively-identified perforator location, with the posterior border of the fibula employed as an axis, and the perforator vessel as the pivot point of rotation. Patients were followed-up to determine the outcomes. Results The study analysed 36 patients (mean age, 39.7 years). The majority of the soft tissue defects were on the heel (20; 55.6%). The donor-site of the flap was closed in 11 patients by direct suturing and skin grafting was undertaken in 25 patients. Postoperative complications included venous congestion (nine patients), which was managed with delayed wound coverage and bleeding therapy. All wounds were eventually cured and the flaps were cosmetically acceptable. Conclusions The peroneal perforator pedicle propeller flap is an appropriate choice to repair soft tissue defects of the distal limbs.
Kang, Jin Seok; Choi, Hwan Jun; Tak, Min Sung
2016-06-01
Free flaps are still the gold standard for large defects of the lower limb, but propeller perforator flaps have become a simpler and faster alternative to free flaps because of some advantages such as reliable vascular pedicle, wide mobilization and rotation, great freedom in design, low donor site morbidity, and easy harvest with no requirement for anastomosis. But when the vessels show insufficient findings in preoperative evaluation using a Doppler probe or the vessel is injured, the surgeon should avoid performing free flap surgery to prevent flap failure and should select a propeller perforator flap as an alternative method on the condition that more than one perforator is intact. In this study, we report reconstruction of soft tissue defects of the heel with a pedicled propeller flap in postfasciotomy and popliteal artery revascularization state by making an incision on the central portion above the Achilles tendon, which can be covered by the posterior tibial artery perforator or the peroneal artery perforator based flaps. In conclusion, we showed that although the popliteal artery was injured, the soft tissue defect can be reconstructed using a perforator propeller flap if intact distal flow in the anastomosis site was confirmed. © The Author(s) 2015.
The First Dorsal Metatarsal Artery Perforator Propeller Flap.
Hallock, Geoffrey G
2016-06-01
Distal foot and toe defects requiring a vascularized flap for coverage have very limited options, oftentimes justifying even a free flap. Perforator flaps in general and propeller flaps in particular have opened up an entirely new subset of local tissue transfer alternatives that can potentially avoid the difficulties that accompany microvascular tissue transfers. The first dorsal metatarsal artery (FDMA) perforator propeller flap represents another variation of this theme. A standard FDMA flap from the dorsum of the foot was raised in reversed fashion based on the distal communicating branch or "perforator" from the plantar foot circulation in 2 patients with great toe defects. All distal skin tissue between this perforator and the defect was kept with the FDMA flap as an attached minor blade, to thereby create an FDMA propeller flap. Salvage of the great toe in both patients was achieved. The benefit of the minor blade of the propeller was to fill a portion of the donor site defect of the traditional FDMA major blade, to permit tension-free donor site closure of the dorsal foot without sequela. The distal-based FDMA flap can be useful as a local flap for coverage of distal foot and toe wounds, but direct donor site closure can be problematic as mirrored by its relative the dorsalis pedis flap. The FDMA perforator propeller flap variation can achieve the same reconstructive goals while simultaneously transferring vascularized tissue into the dorsal foot donor site to thereby minimize the tension if direct closure is possible or minimize the need for a skin graft in this notoriously difficult region.
Rozen, Warren M; Fox, Carly M; Leong, James; Morsi, Adel
2013-11-01
Multiple variations of the musculocutaneous trapezius flap have been described, each of which use a single composite musculocutaneous unit in their designs. The limitation of such designs is the ability to use the components in a 3-dimensional manner, with only 1 vector existing in the geometry of the musculocutaneous unit. A review of the literature was undertaken with regard to designs of the musculocutaneous trapezius flap, and we present a new technique for flap design. With identification of individual perforators to each of the muscle and fasciocutaneous portions of the trapezius flap, the 2 components can act in a chimeric fashion, able to fill both a deep and complex 3-dimensional space while covering the wound with robust skin. A range of flap designs have been described, including transverse, oblique, and vertical skin paddles accompanying the trapezius muscle. We describe a technique with which a propeller-style skin paddle based on a cutaneous perforator can be raised in any orientation with respect to the underlying muscle. In a presented case, separation of the muscular and fasciocutaneous components of the trapezius flap was able to obliterate dead space around exposed cervicothoracic spinal metalwork and obtain robust wound closure in a patient with previous radiotherapy. This concomitant use of a muscle and fasciocutaneous perforator flap based on a single perforator, a so-called chimeric perforator flap, is a useful modification to trapezius musculocutaneous flap design.
[Preoperative CT angiography for planning free perforator flaps in breast reconstruction].
Kuekrek, H; Müller, D; Paepke, S; Dobritz, M; Machens, H-G; Giunta, R E
2011-04-01
Preoperative Doppler ultrasonography for planning free perforator flaps is widely established to identify preoperatively perforators. The method allows one to localise the penetrating point of the perforator through the abdominal fascia. By this means it is not possible to see the intramuscular course or the position of the perforator in relation to the inferior epigastric artery. Lately the technique of computed tomographic angiography provides an opportunity for visualising the course of perforator vessels in these tissues. This paper summarises our experience with the preoperative CT angiography in our breast centre. Since spring 2009 we have reconstructed the breasts of 44 female patients by using free flaps from the lower abdominal wall. 6 of these were bilateral. In a total number of 50 breast reconstructions we used 23 deep inferior epigastric perforator (DIEP) flaps and 27 muscle-sparing transverse rectus abdominis muscle (TRAM) flaps. In addition to the preoperative ultrasonography, a CT angiography of the lower abdomen was conducted in 29 patients. On average they showed at least 2 perforators on the left as well as right abdominal sides, which could be used as flap vessels based on their signal intensity. Based on their estimated microsurgical dissection complexity, the perforator vessels could be classified into 3 groups: 1) direct perforators of category A with short intramuscular course (39%), 2) perforators with long intramuscular course of category B (50%) and 3) "turn around" perforators of category C, which pass medially around the rectus abdominis (11%). The technique of CT angiography permits a reliable preoperative visualisation of perforators in their entire course and facilitates the selection of the supplying perforator as well as the intraoperative procedure for the surgeon. The suggested classification of perforators into 3 groups simplifies the preoperative assessment of the microsurgical dissection effort. Compared to the commonly used Doppler ultrasonography there are disadvantages like the additional cost factor and the radiation exposure. However, in our experience the more detailed planning increases the safety of flap raising and reduces surgery time, so that we consider CT angiography a positive tool to facilitate free perforator flaps. © Georg Thieme Verlag KG Stuttgart · New York.
Ademola, Samuel A; Michael, Afieharo I; Oladeji, Femi J; Mbaya, Kefas M; Oyewole, O
2015-01-01
Reverse sural artery fasciocutaneous flap has become a workhorse for the reconstruction of distal leg soft tissue defects. When its use is not feasible, perforator-based propeller flap offers a better, easier, faster, and cheaper alternative to free flap. We present our experience with two men both aged 34 years who sustained Gustilo 3B injuries from gunshot. The donor area for reversed sural artery flap was involved in the injuries. They had early debridement, external fixation, and wound coverage with perforator-based propeller flaps. The donor sites were covered with skin graft. All flaps survived. There were minor wound edge ulcers due to the pressure of positioning that did not affect flap survival and the ulcers healed with conservative management. Perforator-based propeller flap is a versatile armamentarium for reconstruction of soft tissue defects of the distal leg in resource-constrained settings, especially when the donor area for a reverse flow sural flap artery is involved in the injury.
Bonomi, Stefano; Salval, André; Brenta, Federica; Rapisarda, Vincenzo; Settembrini, Fernanda
2016-09-01
Many procedures have been proposed for the treatment of pressure sores, and V-Y advancement flaps are widely used to repair a defect. Unfortunately, the degree of mobility of a V-Y advancement flap is dependent on the laxity of the underlying subcutaneous tissue. This is an important disadvantage of traditional V-Y advancement flap and limits its use.We used V-Y advancement flaps as perforator-based to overcome mobility restriction problem, with a further modification (Pacman-like shape) to improve the covering surface area of the flap. Between January 2012 and December 2014, the authors used 37 V-Y Pacman perforator-based flaps in 33 consecutive patients for coverage of defects located at sacral (n = 21), ischial (n = 13), trochanter (n = 1) regions. There were 27 male and 6 female patients with a mean age of 49.9 years (range, 15-74 years). All flaps survived completely (92.3%) except 3 in which one of them had undergone total necrosis due to hematoma and the other 2 had partial necrosis. No venous congestion was observed. The mean follow-up period was 14.9 months (range, 2-38 months). No flap surgery-related mortality or recurrence of pressure sores was noted. The V-Y Pacman perforator-based advancement flaps are safe and very effective for reconstruction of pressure sores at various regions. The advantage of our modification procedure include shorter operative time, lesser pedicle dissection, low donor site morbidity, good preservation of muscle, and offers remarkable excursion to the V-Y flap, which make the V-Y Pacman perforator-based flaps an excellent choice for large pressure sore coverage.
Zang, Mengqing; Yu, Shengji; Xu, Libin; Zhao, Zhenguo; Zhu, Shan; Ding, Qiang; Liu, Yuanbo
2015-06-01
Trunk defects following soft tissue sarcoma resection are usually managed by myocutaneous flaps or free flaps. However, harvesting muscle will cause functional morbidities and some trunk regions lack reliable recipient vessels. The intercostal arteries give off multiple perforators, which distribute widely over the trunk and can supply various pedicle flaps. Our purpose is to use various intercostal artery perforator propeller flaps for trunk oncologic reconstruction. Between November 2013 and July 2014, nine intercostal artery perforator propeller flaps were performed in seven patients to reconstruct the defects following sarcoma resection in different regions of the trunk, including the back, lumbar, chest, and abdomen. Two perforators from intercostal arteries were identified for each flap using Doppler ultrasound probe adjacent to the defect. The perforator with visible pulsation was chosen as the pedicle vessel. An elliptical flap was raised and rotated in a propeller fashion to repair the defects. There were one dorsal intercostal artery perforator flap, four dorsolateral intercostal artery perforator flaps, three lateral intercostal artery perforator flaps, and one anterior intercostal artery perforator flap. The mean skin paddle dimension was 9.38 cm in width (range 6-14 cm) and 21.22 cm in length (range 13-28 cm). All intercostal artery perforator flaps survived completely, except for marginal necrosis in one flap harvested close to the previous flap donor site. The intercostal artery perforator propeller flap provides various and valuable options in our reconstructive armamentarium for trunk oncologic reconstruction. To our knowledge, this is the first case series of using intercostal artery perforator propeller flaps for trunk oncologic reconstruction and clinical application of dorsolateral intercostal artery perforator flaps. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
The "Tokyo" consensus on propeller flaps.
Pignatti, Marco; Ogawa, Rei; Hallock, Geoffrey G; Mateev, Musa; Georgescu, Alexandru V; Balakrishnan, Govindasamy; Ono, Shimpei; Cubison, Tania C S; D'Arpa, Salvatore; Koshima, Isao; Hyakusoku, Hikko
2011-02-01
Over the past few years, the use of propeller flaps, which base their blood supply on subcutaneous tissue or isolated perforators, has become increasingly popular. Because no consensus has yet been reached on terminology and nomenclature of the propeller flap, different and confusing uses of the term can be found in the literature. In this article, the authors report the consensus on the definition and classification of propeller flaps reached by the authors that gathered at the First Tokyo Meeting on Perforator and Propeller Flaps in June of 2009. Some peculiar aspects of the surgical technique are discussed. A propeller flap can be defined as an "island flap that reaches the recipient site through an axial rotation." The classification is based on the nourishing pedicle (subcutaneous pedicled propeller flap, perforator pedicled propeller flap, supercharged propeller flap), the degrees of skin island rotation (90 to 180 degrees) and, when possible, the artery of origin of the perforator. The propeller flap is a useful reconstructive tool that can achieve good cosmetic and functional results. A flap should be called a propeller flap only if it fulfils the definition above. The type of nourishing pedicle, the source vessel (when known), and the degree of skin island rotation should be specified for each flap.
Perforator Flaps after Excision of Large Epidermal Cysts in the Buttocks
Kim, Sang Wha; Yang, Seong Hyeok; Kim, Jeong Tae
2014-01-01
Background Epidermal cysts are commonly occurring masses usually less than 5 cm in diameter, but in predisposed patients, epidermal cysts can grow relatively large due to chronic infection. Methods From June 2002 to July 2010, 17 patients received 19 regional perforator-based island flaps to cover defects due to the excision of large epidermal cysts (diameter >5 cm) in the buttocks. Eight patients had diabetes, and seven had rheumatoid arthritis. The pedicles were not fully isolated to prevent spasms or twisting. Results All the flaps survived completely, except for one case with partial necrosis of the flap, which necessitated another perforator-based island flap for coverage. There were two cases of wound dehiscence, which were re-closed after meticulous debridement. There were no recurrences of the masses during follow-up periods of 8.1 months (range, 6-12 months). Conclusions In patients with large epidermal cysts and underlying medical disorders, regional perforator-based island flaps can be the solution to coverage of the defects after excision. PMID:24665422
Plantar flaps based on perforators of the plantar metatarsal/common digital arteries.
Valentin, Georgescu Alexandru; Rodica, Matei Ileana; Manuel, Llusa
2014-09-01
Because of the unique characteristics of its integument, the affirmation "replacing like with like" becomes more than evident in the reconstruction of defects of the ultraspecialized plantar skin. But, the paucity of local resources, and especially in the forefoot, transforms this attempt in a very challenging problem. Many techniques, including skin grafts and various types of flaps were used in the management of defects in the forefoot. We present a new useful flap in the reconstruction of skin defects in the forefoot, based on small perforator vessels originating either from the plantar metatarsal arteries or plantar common digital arteries. Starting with June 2011, this flap was performed, as plantar transposition perforator flap, plantar propeller flap, or plantar propeller perforator plus flap, in seven patients with ulcers over the plantar forefoot. During a follow-up of 7 to 17 months (mean, 9.8 months), the local evolution regarding flap integration, pain, relapse, sensitive recovery, donor site, and footwear quality was analyzed. We registered a 100% survival rate of the flaps, with delayed healing in only one case. The gait resumption was possible after 6 weeks in all cases. This new flap, based on small perforator vessels from the plantar metatarsal or common digital arteries, and which provides a good, stable, and sensory recovery, seems to be a promising method in the reconstruction of plantar skin defects over the metatarsal heads. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Yin, Xinghong; Hu, Wei; Zhang, Xinhai; Sun, Min
2014-10-01
To explore curative effect with pedicle flap of nasal septum-basis nasi and temporal muscucofascial flap to repair nasal septal perforation. Dissecting mucoperichondrium and mucoperioseptum around the perforation and taking dowm and out xia-ward to the floor of nasal cavity to make a inferior extremity pedicle flap. Then,the flap was tumbled and sutured onto raw surface of contralateral side through perforation. Reapplicating autoallergic temporal musculofascial flap to repair another side perforation. Repairing perforation Sin twelve cases were sucessfully healed in endoscope. The pedicle flap of nasal septum-basis nasi and temporal muscucofascial flap is easy to acquire and no rejection. The flap has good blood supplying, high survival rate and provides adequate transplantating materail to repair comparatively large perforation.
Free-style puzzle flap: the concept of recycling a perforator flap.
Feng, Kuan-Ming; Hsieh, Ching-Hua; Jeng, Seng-Feng
2013-02-01
Theoretically, a flap can be supplied by any perforator based on the angiosome theory. In this study, the technique of free-style perforator flap dissection was used to harvest a pedicled or free skin flap from a previous free flap for a second difficult reconstruction. The authors call this a free-style puzzle flap. For the past 3 years, the authors treated 13 patients in whom 12 pedicled free-style puzzle flaps were harvested from previous redundant free flaps and recycled to reconstruct soft-tissue defects at various anatomical locations. One free-style free puzzle flap was harvested from a previous anterolateral thigh flap for buccal cancer to reconstruct a foot defect. Total flap survival was attained in 12 of 13 flaps. One transferred flap failed completely. This patient had received postoperative radiotherapy after the initial cancer ablation and free anterolateral thigh flap reconstruction. Another free flap was used to close and reconstruct the wound. All the donor sites could be closed primarily. The free-style puzzle flap, harvested from a previous redundant free flap and used as a perforator flap to reconstruct a new defect, has proven to be versatile and reliable. When indicated, it is an alternative donor site for further reconstruction of soft-tissue defects.
Wei, Jiao; Herrler, Tanja; Gu, Bin; Yang, Mei; Li, Qingfeng; Dai, Chuanchang; Xie, Feng
2018-05-01
The repair of extensive upper limb skin lesions in pediatric patients is extremely challenging due to substantial limitations of flap size and donor-site morbidity. We aimed to create an oversize preexpanded flap based on intercostal artery perforators for large-scale resurfacing of the upper extremity in children. Between March 2013 and August 2016, 11 patients underwent reconstructive treatment for extensive skin lesions in the upper extremity using a preexpanded intercostal artery perforator flap. Preoperatively, 2 to 4 candidate perforators were selected as potential pedicle vessels based on duplex ultrasound examination. After tissue expander implantation in the thoracodorsal area, regular saline injections were performed until the expanded flap was sufficient in size. Then, a pedicled flap was formed to resurface the skin lesion of the upper limb. The pedicles were transected 3 weeks after flap transfer. Flap survival, complications, and long-term outcome were evaluated. The average time of tissue expansion was 133 days with a mean final volume of 1713 mL. The thoracoabdominal flaps were based on 2 to 6 pedicles and used to resurface a mean skin defect area of 238 cm ranging from 180 to 357 cm. In all cases, primary donor-site closure was achieved. Marginal necrosis was seen in 5 cases. The reconstructed limbs showed satisfactory outcome in both aesthetic and functional aspects. The preexpanded intercostal artery perforator flap enables 1-block repair of extensive upper limb skin lesions. Due to limited donor-site morbidity and a pedicled technique, this resurfacing approach represents a useful tool especially in pediatric patients.
Perforator Peroneal Artery Flap for Tongue Reconstruction.
Chauhan, Shubhra; Chavre, Sachin; Chandrashekar, Naveen Hedne; B S, Naveen
2017-03-01
Reconstruction has evolved long way from primary closure to flaps. As time evolved, better understanding of vascularity of flap has led to the development of innovative reconstructive techniques. These flaps can be raised from various parts of the body for reconstruction and have shown least donor site morbidity. We use one such peroneal artery perforator flap for tongue reconstruction with advantage of thin pliable flap, minimal donor site morbidity and hidden scar. Our patient 57yrs old lady underwent wide local excision with selective neck dissection. Perforators are marked about 10 and 15 cm inferiorly from the fibular head using hand held Doppler. Leg is positioned in such a way to give better exposure during dissection of the flap and flap is harvested under a tourniquet with pressure kept 350 mm Hg. The perforator is kept at the eccentric location, so as to gain length of the pedicle. Skin incison is placed over the peroneal muscle and deepened unto the deep facia, then the dissection is continued over the muscle and the perforator arising from the lateral septum. The proximal perforator about 10 cm from the fibular head is a constant perforator and bigger one, which is traced up to the peroneal vessel. We could get a 6 cm of pedicle length. Finally the flap is islanded on this perforator and the pedicle is ligated and flap harvested. Anastamosis was done to the ipsilateral side to facial vessels. The donor site is closed primarily and in the upper half one can harvest 5 cm width flap without requiring a skin graft along with a length of 8 to 12 cm. Various local and free flap has been used for reconstruction of partial tongue defects with its obvious donor site problems, like less pliable skin and not so adequate tissue from local flaps and sacrificing a important artery as in radial forearm flap serves as the work horse in reconstruction of partial tongue defects, Concept of super microsurgery was popularized by Japanese in 1980s and the concept of angiosome proposed by Taylor paved the way for development of new flaps. True perforator flaps are those where the source vessel is left undisturbed and overlying skin flap is raised. Yoshimura proposed cutaneous flap could be raised from peroneal artery (Br J Plast Surg 42:715-718, 1989). Wolff et al. (Plast Reconstr Surg 113:107-113, 2004) first used perforator based peroneal artery flap for oral reconstruction. Location of perforators vary, hence pre operative localisation can be done by ultrasound doppler, CT angio or MR angiography. Disadvantages over radial flap include varying anatomic location of perforators, need for imaging and difficult dissection of delicate vessels through muscles and hence a learning curve. Our patient had an arterial thrombus within few hours post-operatively which was successfully salvaged with immediate re-exploration and re-anastomosis of artery. Post-operative healing was uneventful and donor site was closed primarily without the need for graft. Perforator peroneal flap serves as a useful armamentarium for reconstruction of moderate size defects of tongue, buccal mucosa and floor of mouth with advantages of thin pliable flap, minimal donor site morbidity and hidden scar.
Struk, S; Schaff, J-B; Qassemyar, Q
2018-04-01
The medial sural artery perforator (MSAP) flap is defined as a thin cutaneo-adipose perforator flap harvested on the medial aspect of the leg. The aims of this study were to describe the anatomical basis as well as the surgical technique and discuss the indications in head and neck reconstructive surgery. We harvested 10 MSAP flap on 5 fresh cadavers. For each case, the number and the location of the perforators were recorded. For each flap, the length of pedicle, the diameter of source vessels and the thickness of the flap were studied. Finally, we performed a clinical application of a MSAP flap. A total of 23 perforators with a diameter superior than 1mm were dissected on 10 legs. The medial sural artery provided between 1 and 4 musculocutaneous perforators. Perforators were located in average at 10.3cm±2cm from the popliteal fossa and at 3.6cm±1cm from the median line of the calf. The mean pedicle length was 12.1cm±2.5cm. At its origin, the source artery diameter was 1.8mm±0.25mm and source veins diameters were 2.45mm±0.9mm in average. There was no complication in our clinical application. This study confirms the reliability of previous anatomical descriptions of the medial sural artery perforator flap. This flap was reported as thin and particularly adapted for oral cavity reconstruction and for facial or limb resurfacing. Sequelae might be reduced as compared to those of the radial forearm flap with comparable results. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Gebert, L; Boucher, F; Lari, A; Braye, F; Mojallal, A; Ismaïl, M
2018-04-01
The surgical management of pressure ulcers in the paraplegic or quadriplegic population is marked by the high risk of recurrence in the long-term. In the current era of perforator flaps, newer reconstructive options are available for the management of pressure ulcers, decreasing the need to use the classically described muscular or musculocutaneous locoregional flaps. The coverage of ischial sores described in this article by a pedicled flap based on a deep femoral artery perforator, appears to be an effective first-line reconstructive option for the management of limited size pressure ulcers. A number of fifteen paraplegic or quadriplegic patients having at least one ischial bed sore with underlying osteomyelitis were included in this series. The approximate location of the deep femoral artery perforator was initially identified using the "The Atlas of the perforator arteries of the skin, the trunk and limbs", which was confirmed, with the use of a Doppler device. A fasciocutaneous transposition flap was elevated, with the pivot point based on the cutaneous bridge centered on the perforator, and then transposed to cover the area of tissue loss. The donor site was closed primarily. A total of fifteen patients were operated from November 2015 to November 2016. The series comprised of 16 first presentations of a stage 4 pressure ulcers associated with underlying osteomyelitis that were subsequently reconstructed by the pedicled deep femoral artery perforator flap. The healing rate and functional results were both satisfactory. Fasciocutaneous flap reliable by deep femoral artery perforator appears to have a promising role in the treatment of ischial pressure sores. It is an attractive option to spare the use of musculocutaneous flaps in the area. Thus this flap could be used as a first-line option to cover ischial pressure ulcers of limited size. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Battaglia, Salvatore; Maiolo, Vincenzo; Savastio, Gabriella; Zompatori, Maurizio; Contedini, Federico; Antoniazzi, Elisa; Cipriani, Riccardo; Marchetti, Claudio; Tarsitano, Achille
2017-10-01
Mandibular reconstruction performed after virtual planning has become more common during recent years. The gold standard for extensive mandibular reconstruction is of course a fibular free flap. In designing an osteomyocutaneous fibula flap, poor planning, aberrant anatomy and/or inadequate perforator vessels are the most frequent causes of complications and may force the surgeon to modify the flap design, explore the contralateral leg or harvest an additional microvascular flap. The goal of our study was to pre-operatively evaluate the vascular anatomy of the fibula and localize the cutaneous perforator vessels, so to create the fibular cutting guide based on the position of the cutaneous perforator and safely harvest the reconstructive flap. Twenty consecutive patients who were candidates for mandibular reconstruction using a fibular microvascular free flap were enrolled in this study between January 2016 and August 2016. The patients were preoperatively assessed with a Computed Tomographic scan of head and neck and with a Computed Tomographic Angiography (CTA) scan of the lower limbs to evaluate the vascular anatomy of the fibula. Virtual planning was carried out for all patients. The fibular cutting guide was based on the position of the perforator cutaneous vessels, which were used to harvest the cutaneous part of the flap. Preoperative CT measurements were performed in order to identify the cutaneous perforators on the patients' skin. Intraoperative checking was performed to evaluate the accuracy of the perforators' position and the reproducibility of the virtual planning. In 5 patients out of 20 (25%), anatomical anomalies were discovered, without clinical evidence. The perforator vessels were localized in all patients. The average difference between the CTA and the intraoperative perforator localization was 1 mm (range 0-2 mm). Fibular cutting guide was positioned and fitted the anatomy of the patients in all treated patients. This allowed us to perform the planned segmentation of the fibula, obtaining the correct number of segments. In all cases, flap insetting was carried out and skin paddle was positioned as preoperatively planned. Neither donor site complications nor flap complications occurred. Preoperative evaluation of the legs using CTA, in patients who undergo an osteomyocutaneous fibular free flap for mandibular reconstruction, is a valuable approach to reduce altered-anatomy related complications and to improve the accuracy and outcomes of the reconstruction, especially in reconstructions of complex defects. In these cases, a soft tissue-based cutting guide can be planned based on the perforator vessels of the skin paddle, minimizing the harvesting risks of vascular lesions. Further studies and longer follow-ups are needed to evaluate the long-term outcomes and advantages of this procedure. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
[Reconstruction of ankle and foot with combination of free perforator flaps and skin graft].
Yin, Lu; Gong, Ketong; Yin, Zhonggang; Zhang, Bo; Xu, Jianhua
2017-03-01
To evaluate the clinical outcomes of free perforator flaps combined with skin graft for reconstruction of ankle and foot soft tissue defects. Between June 2014 and October 2015, 20 cases of ankle and foot soft tissue defects were treated. There were 16 males and 4 females, aged from 19 to 61 years (mean, 43.3 years). Injury was caused by traffic accident in 7 cases, by crashing in 9 cases, and machine twist in 4 cases. The locations were the ankle in 6 cases, the heel in 3 cases, the dorsum pedis in 4 cases, and the plantar forefoot in 7 cases of avulsion injury after toes amputation. The size of wound ranged from 15 cm×10 cm to 27 cm×18 cm. The time from injury to treatment was from 11 to 52 days (mean, 27 days). The anterolateral thigh perforator flap was used in 11 cases, thoracodorsal antery perforator flap in 3 cases, medial sural artery perforator flap in 4 cases, deep inferior epigastric perforator flap in 1 case, and anteromedial thigh perforator flap in 1 case, including 5 chimeric perforator flaps, 5 polyfoliate perforator flaps, 3 flow-through perforator flaps, and 3 conjoined perforator flaps. The size of the perforator flap ranged from 10.0 cm×6.5 cm to 36.0 cm×8.0 cm, the size of skin graft from 5 cm×3 cm to 18 cm×12 cm. Venous crisis occurred in 2 flaps which survived after symptomatic treatment; 18 flaps survived successfully and skin grafting healed well. The follow-up time ranged 4-18 months (mean, 8.3 months). The flaps had good appearance, texture and color, without infection. The patients could walk normally and do daily activities. Only linear scars were observed at the donor sites. Free perforator flap can be used to reconstruct defects in the ankle and foot, especially in the weight-bearing area of the plantar forefoot. A combination of free perforator flap and skin graft is ideal in reconstruction of great soft tissue defects in the ankle and foot.
Unal, Cigdem; Ozdemir, Jale; Yirmibesoglu, Oktay; Yucel, Ergin; Agir, Hakan
2012-07-01
Reconstructive surgery for ischial pressure sore defects presents a challenge because of high rates of recurrence. The aim of this study was to describe the use of inferior gluteal artery (IGA) and posterior thigh perforators in management of ischial pressure sores with limited donor sites. Between September 2005 and 2009, 11 patients (9 male, 2 female) with ischial sores were operated by using IGA and posterior thigh perforator flaps. The data of patients included age, sex, cause of paraplegia, flap size, perforator of flap, previous surgeries, recurrences, complications, and postoperative follow-up. Nine IGA and 5 posterior thigh perforator flaps were used. Six patients presented with recurrent lesions, 5 patients were operated for sacral and contralateral ischial pressure sores previously. In 2 patients, IGA and posterior thigh perforator flaps were used in combination. Patients were followed for an average of 34.3 months. In 2 recurrent cases, readvancement of IGA perforator flap and gluteus maximus myocutaneous flap were treatment of choice. Treatment of patients with recurrent lesions or multiple pressure sores is challenging because of limited available flap donor sites. In this study, posterior thigh perforator flaps were preferred in patients in whom the previous donor site was the gluteal region. IGA perforator flaps were the treatment of choice in patients for whom posterior thigh region was previously used. Alternately, preserved perforators of previous conventional myocutaneous flaps enabled us to use these perforators in recurrences.
Duncumb, Joseph W; Miyagi, Kana; Forouhi, Parto; Malata, Charles M
2016-01-01
Abdominal free flaps for microsurgical breast reconstruction are most commonly harvested based on the deep inferior epigastric vessels that supply skin and fat via perforators through the rectus muscle and sheath. Intact perforator anatomy and connections are vital for subsequent optimal flap perfusion and avoidance of necrosis, be it partial or total. The intraflap vessels are delicate and easily damaged and it is generally advised that patients should avoid heparin injection into the abdominal pannus preoperatively as this may compromise the vascular perforators through direct needle laceration, pressure from bruising, haematoma formation, or perforator thrombosis secondary to external compression. We report three cases of successful deep inferior epigastric perforator (DIEP) flap harvest despite patients injecting therapeutic doses of low molecular weight heparin into their abdomens for thrombosed central venous lines (portacaths™) used for administering primary chemotherapy in breast cancer.
Miyagi, Kana; Forouhi, Parto
2016-01-01
Abdominal free flaps for microsurgical breast reconstruction are most commonly harvested based on the deep inferior epigastric vessels that supply skin and fat via perforators through the rectus muscle and sheath. Intact perforator anatomy and connections are vital for subsequent optimal flap perfusion and avoidance of necrosis, be it partial or total. The intraflap vessels are delicate and easily damaged and it is generally advised that patients should avoid heparin injection into the abdominal pannus preoperatively as this may compromise the vascular perforators through direct needle laceration, pressure from bruising, haematoma formation, or perforator thrombosis secondary to external compression. We report three cases of successful deep inferior epigastric perforator (DIEP) flap harvest despite patients injecting therapeutic doses of low molecular weight heparin into their abdomens for thrombosed central venous lines (portacaths™) used for administering primary chemotherapy in breast cancer. PMID:27651974
Cordova, Adriana; Pirrello, Roberto; D'Arpa, Salvatore; Jeschke, Johannes; Brenner, Erich; Moschella, Francesco
2008-11-01
The supraclavicular skin has been studied extensively and used as a pedicled flap for face and neck reconstruction. Its use as a free flap has not paralleled its use as a pedicled flap. The authors performed an anatomical investigation to assess the possibility of harvesting a free supraclavicular flap with the donor-site scar lying in the supraclavicular crease. In this article, the authors present the results of their anatomical study together with the preliminary clinical applications. Skin vascularization and feasibility of a free supraclavicular perforator flap were studied on 25 cadavers (15 fresh cadavers injected with colored latex at the Universiteé René Descartes in Paris; and 10 formalin-fixed, noninjected cadavers at the Innsbruck Medical University). The flap was used in two patients at the Plastic Surgery Department of the University of Palermo for a cutaneous facial reconstruction and intraoral reconstruction after cancer excision. An average of four perforators were consistently found in the supraclavicular area coming from the transverse cervical artery. Venous perforators drain into the superficial venous plexus rather than into the venae comitantes of the transverse cervical artery. Two flaps were successfully used based on these vessels. The vascularization of the supraclavicular skin depends on skin perforators coming from the transverse cervical artery and draining into the superficial venous plexus. Based on these vessels, a reliable free supraclavicular flap seems to be safe to harvest, with the scar hidden in the supraclavicular crease. The preliminary clinical applications of such a flap gave promising results, suggesting its potential applications.
Perforator-based propeller flaps for leg reconstruction in pediatric patients.
Özalp, Burhan; Aydınol, Mustafa
2016-10-01
Perforator-based propeller flaps provide adequate soft tissue coverage for leg reconstruction. The aim of this study was to assess the versatility and reliability of the use of propeller flaps for leg reconstruction in pediatric patients. Seven male pediatric patients ranging in age from 2 to 13 years with a mean age of 6.7 underwent perforator-based propeller flap surgery over a four-year period. The defects resulted from burn injuries (n = 4) and traffic accidents (n = 3). The injuries were located on the ankles of four patients and on the knee, anterior lower tibia, and foot dorsum of the other three patients, respectively. The flap sizes ranged from 5 × 3 to 10 × 6 cm with a mean flap size of 7.6 × 4.3 cm. Flap harvesting time ranged from 38 to 56 m with a mean of 46 m. The rotation degree range of the flaps was from 90° to 180°. The propeller flaps were based on the posterior tibial artery (n = 4), anterior tibial artery (n = 2), and the descending branch of the lateral circumflex femoral artery (n = 1). All flaps survived completely without surgical complication; however, one patient developed disseminated intravascular coagulation syndrome two days post-surgery and died within four days. Perforator-based propeller flap reconstruction is a safe, reliable, and versatile method for lower extremities in pediatric patients; however, it requires meticulous surgical dissection and extreme patience during the surgical procedure. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Scalise, Alessandro; Tartaglione, Caterina; Bolletta, Elisa; Pierangeli, Marina; Di Benedetto, Giovanni
2015-08-01
We report the case of a 50-year-old paraplegic man with a complicated grade III/IV ischiatic pressure sore treated with a propeller flap based on the first perforator of the profunda femoris artery. Our aim was to surgically reconstruct an ischiatic pressure sore in a patient with ankylosis using a fasciocutaneous perforator propeller flap obtained from the posterior region of the thigh. Our decision to perform a profunda femoris artery perforator propeller flap reconstruction was mainly due to the anatomical contiguity of the flap with the site of the lesion and the good quality of the skin harvested from the posterior region of the thigh. The use of the perforator fasciocutaneous flap represents a muscle-sparing technique, providing a better long-term result in surgical reconstruction. The choice of the 180-degree propeller flap was due to its ability to provide a good repair of the pressure ulcer and to pass over the ischiatic prominence in the patient in the forced decubitus position. The operatory course did not present any kind of complication. Using this reconstructive treatment, we have obtained complete coverage of the ischiatic pressure sore.
Brunetti, Beniamino; Tenna, Stefania; Aveta, Achille; Poccia, Igor; Segreto, Francesco; Cerbone, Vincenzo; Persichetti, Paolo
2016-10-01
Few studies in the recent literature have investigated the reliability of dorsal intercostal artery perforator (DICAP) flap in posterior trunk reconstruction. The purpose of this report is to describe our clinical experience with the use of DICAP flaps in a cohort of oncological patients. Twenty patients underwent posterior trunk reconstruction with DICAP based flaps. Patients age ranged from 45 to 76 years. All defects resulted from skin cancer ablation. Defect sizes ranged from 4 × 4 to 6 × 8 cm. The flaps were mobilized in V-Y or propeller fashion. The flaps were islanded on 1 (12 cases), 2 (6 cases), or 3 (2 cases) perforators. Donor sites were always closed primarily. Eleven V-Y advancement flaps were performed; one of these was converted to a perforator-plus peninsular flap design, which retained an additional source of blood supply from the opposite skin bridge. Nine flaps were mobilized in propeller fashion. Flap dimensions ranged from 4 × 6 to 6 × 14 cm. Mean operative time was 70 min. One V-Y flap complicated with marginal necrosis that healed with no need for reintervention. All the other flaps survived uneventfully. No other complications were observed at recipient and donor sites. Follow-up ranged from 3 months to 2 years. All the patients were satisfied with the surgical outcome. DICAP based flaps proved to be a reliable option to resurface posterior trunk defects following oncological resection, allowing to achieve like-with-like reconstruction with excellent contour and minimal donor-site morbidity. © 2015 Wiley Periodicals, Inc. Microsurgery 36:546-551, 2016. © 2015 Wiley Periodicals, Inc.
Lower Extremity Free Flaps for Breast Reconstruction.
Dayan, Joseph H; Allen, Robert J
2017-11-01
Thigh-based flaps are typically a secondary option for breast reconstruction because of concerns regarding limited tissue volume and donor-site morbidity. In recent years, there have been a number of new techniques and insights that have resulted in greater flexibility and improved outcomes. This article reviews lessons learned from a large collective experience using the following 4 flaps: transverse upper gracilis also known as transverse myocutaneous gracilis, diagonal upper gracilis, profunda artery perforator, and lateral thigh perforator flaps. Flap selection considerations include the patient's fat distribution and skin laxity, perforator anatomy, and scar location. Pearls to minimize donor-site morbidity include avoiding major lymphatic collectors in the femoral triangle and along the greater saphenous vein and respecting the limits of flap dimension to reduce wound healing complications and distal ischemia. Limited flap volume may be addressed with stacking another flap from the contralateral thigh or primary fat grafting as opposed to overaggressive flap harvest from a single thigh. A detailed review of the benefits and disadvantages of each flap and strategies to improve results is discussed. With careful planning and selection, thigh-based flaps can provide a reliable option patients desiring autologous breast reconstruction.
Vertical Profunda Artery Perforator Flap for Plantar Foot Wound Closure: A New Application.
Alfonso, Allyson R; Mayo, James L; Sharma, Vishal K; Allen, Robert J; Chiu, Ernest S
2018-02-01
Plantar foot reconstruction requires special consideration of both form and function. There are several fasciocutaneous flap options, each with indications and reservations. This case presents a new application of the vertical profunda artery perforator flap for definitive closure of a neuropathic foot ulcer in a young woman with spina bifida. The postoperative course was uneventful, and the flap survived completely. The surgical and donor sites were without wound recurrence at 5-month follow-up. Understanding the variability of foot flap options is important because of unique cases such as the one presented where the wound was caused by specific and less commonly observed foot anatomy. The specific choice to use the vertical profunda artery perforator flap for this patient and her neuropathic wound type was made based on its excellent flexibility, durability, and donor site appeal. The vertical profunda artery perforator flap has adequate surface area and bulk and a favorable pedicle length and caliber, can be thinned, and leaves a donor scar in a less conspicuous area than other popular free flaps for lower-extremity reconstruction. For these reasons, it should be considered a first-line therapy for free flap coverage of selected foot wounds.
The Anterior Interosseus Artery Perforator Flap: Anatomical Dissections and Clinical Study.
Panse, Nikhil S; Joshi, Sheetal B; Sahasrabudhe, Parag B; Bahetee, B; Gurude, Pradnya; Chandanwale, Ajay
2017-05-01
Reconstruction of upper extremity deformities continues to be a challenge to the reconstructive surgeon. Various loco regional, distant and free flaps are available for reconstruction. However, each has its own set of advantages and disadvantages. Of the commonly performed local flaps, radial artery forearm flap, and the posterior interosseus artery flap stand out prominently. Recently, perforator propeller flaps have been used for resurfacing the upper extremity. The anterior interosseus artery perforator flap is an uncommonly used and described flap. This study was divided into anatomical study and clinical application in a IV level of evidence. In the anatomical study, five upper extremities were studied. Clinically, 12 patients underwent reconstruction using the anterior interosseus artery perforator flap. Flaps were performed by a single surgeon. A retrospective review of these cases from November 2008 to May 2014 is presented. The anterior interosseus artery perforator was identified in four out of five cadaver limbs. The septocutaneous perforator was in the fifth extensor compartment around 4 cm proximal to the wrist joint. Of the twelve flaps, there was complete necrosis in one flap, and partial necrosis in one flap. The patient with complete necrosis underwent skin grafting at a later date. The wound healed secondarily in case of partial flap necrosis. Anterior interosseus artery perforator flap must be considered as an important reconstructive option in the armamentarium of the plastic surgeon, while managing hand and wrist defects.
Li, Haizhou; Wang, Zi; Gu, Bin; Gao, Yashan; Xie, Feng; Zhu, Hainan; Li, Qingfeng; Zan, Tao
2018-05-14
For extensive postburn neck deformities, the preexpanded flaps in the upper back region were used and gained a uniform skin appearance and esthetic contours. Free-style perforator-based free-tissue transfer that represents the most recent advance in reconstructive surgery may provide more versatility of these flaps. We retrospectively reviewed 31 patients treated at our institution for postburn neck contracture from March 2010 to May 2016. Various upper back flaps were designed according to the dominant perforators and the shape of the defect after fully releasing the neck contracture. Thirty-one patients received neck reconstructions with the versatile applications of the preexpanded upper back perforator flaps. Tip necrosis was observed in one case, and the others survived completely. The donor sites were all primarily closed. No incision dehiscence was observed. The free-style design has significantly increased the potential and versatility of the upper back flaps in reconstruction of severe neck scar contracture.
de Weerd, Louis; Weum, Sven; Mercer, James B
2009-09-01
The aim of this paper is to evaluate dynamic infrared thermography (DIRT) as a technique to assist in preoperative perforator selection and planning of free deep inferior epigastric perforator (DIEP) flaps. Twenty-seven patients, scheduled for secondary autologous breast reconstruction with either a free DIEP flap or superficial inferior epigastric artery flap, were included in this prospective clinical study. Preoperative mapping of perforators was performed with a hand-held Doppler and DIRT. A multidetector computer tomography scan was additionally carried out in the last 8 patients. In 23 patients a DIEP flap was used. The perforator as selected from DIRT was a suitable perforator in all DIEP flaps. The location and quality of the selected perforator from DIRT corresponded well with the multidetector computer tomography scan results. Preoperative perforator selection and planning of DIEP flaps is facilitated with the use of DIRT. The technique is noninvasive and easy to use.
Fichter, Andreas M; Ritschl, Lucas M; Robitzky, Luisa K; Wagenpfeil, Stefan; Mitchell, David A; Wolff, Klaus-Dietrich; Mücke, Thomas
2016-10-21
The effects of antithrombotic drugs on random and free flap survival have been investigated in the past, but the experimental and clinical results are not in agreement. A perforator-based critical ischaemia model was used to evaluate the effects of different perioperatively administered pharmaceutical agents on tissue ischaemia and to assess the potential additional haemorheological or vasodilative effects of antithrombotics on flap microcirculation. Combined laser Doppler flowmetry and remission spectroscopy revealed an increase in certain microcirculation parameters in most groups in comparison with saline controls, and these changes correlated with flap survival. Clopidogrel and hirudin significantly improved the amount of viable flap tissue in comparison with controls, while unfractioned heparin had a negative effect on flap survival. Low molecular weight heparin, aspirin, pentoxifylline, and hydroxyethyl starch had no impact on the amount of viable flap tissue. A higher complication rate was observed in all experimental groups, but only clopidogrel had a negative impact on the flap viability. Our results add to the body of evidence supporting the conclusion that perioperative antithrombotic treatment improves flap survival. Clopidogrel and hirudin are effective pharmacological agents that significantly increased the viability of perforator-based skin flaps in rats, but at a higher risk of postoperative bleeding.
Reconstruction of lower face defect or deformity with submental artery perforator flaps.
Shi, Cheng-li; Wang, Xian-cheng
2012-07-01
Reconstruction of lower face defects or deformity often presents as a challenge for plastic surgeons. Many methods, including skin graft, tissue expander, or free flap are introduced. Submental artery perforator flaps have been used in the reconstruction of defects or deformities of the lower face. Between August 2006 and December 2008, 22 patients with lower face defects or deformity underwent reconstruction with pedicled submental artery perforator flaps. Their age ranged between 14 and 36 years. The perforator arteries were detected and labeled with a hand-held Doppler flowmeter. The size of flaps ranged from 4 × 6 to 6 × 7 cm, and the designed flaps included the perforator artery. All the flaps survived well, except 1 flap which resulted in partial necrosis in distal region and healed after conservative therapy. No other complication occurred with satisfactory aesthetic appearance of the donor site. The submental artery perforator flap is a thin and reliable flap with robust blood supply. This flap can reduce donor-site morbidity significantly and is a good choice for reconstructive surgery of lower face.
Nasolabial Perforator Flap for One-stage Reconstruction of Nasal Defects
Prakash, Siddharth; Panda, Ritesh; Kumar, Vivek; Saha, Shiv Shankar; Choudhary, Lalit; Pandey, Anurag; Reddy, J. Sasidhar
2017-01-01
Background: The excellent freedom of movement and range of this flap when based on a the nasolabial perforator flap have not been sufficiently explored. In this study, along with demonstrating the other key advantages of this flap over its traditional counterpart, we will endeavour to fill these lacunae in the available literature. Materials and Methods: From February 2009 to February 2012, twenty patients with nasal defects were repaired with a nasolabial perforator flap in the Department of Plastic and Cosmetic Surgery at Sir Ganga Ram Hospital, New Delhi. Of these, two patients (10%) underwent the procedure bilaterally. Thus, a total of 22 nasolabial perforator flap procedures were carried out. Prospectively, collected clinical records and data of each patient were retrospectively retrieved and reviewed to study the nasal defect and surgery done. Results: All the twenty (100%) patients had good functional and aesthetic outcome. All patients who had nasal stenosis preoperatively had very good improvement in the patency of the nasal passages, breathing and nasal blockage with complete recovery of symptoms. The patients were entirely satisfied with the functional recovery. Conclusions: The reliability and versatility of the nasolabial perforator flap exceed its recognised application in reconstruction of nasal defects and it must form a part of every plastic surgeon's armamentarium. PMID:28529417
The Anterior Interosseus Artery Perforator Flap: Anatomical Dissections and Clinical Study
Panse, Nikhil S; Joshi, Sheetal B; Sahasrabudhe, Parag B; Bahetee, B; Gurude, Pradnya; Chandanwale, Ajay
2017-01-01
BACKGROUND Reconstruction of upper extremity deformities continues to be a challenge to the reconstructive surgeon. Various loco regional, distant and free flaps are available for reconstruction. However, each has its own set of advantages and disadvantages. Of the commonly performed local flaps, radial artery forearm flap, and the posterior interosseus artery flap stand out prominently. Recently, perforator propeller flaps have been used for resurfacing the upper extremity. The anterior interosseus artery perforator flap is an uncommonly used and described flap. METHODS This study was divided into anatomical study and clinical application in a IV level of evidence. In the anatomical study, five upper extremities were studied. Clinically, 12 patients underwent reconstruction using the anterior interosseus artery perforator flap. Flaps were performed by a single surgeon. A retrospective review of these cases from November 2008 to May 2014 is presented. RESULTS The anterior interosseus artery perforator was identified in four out of five cadaver limbs. The septocutaneous perforator was in the fifth extensor compartment around 4 cm proximal to the wrist joint. Of the twelve flaps, there was complete necrosis in one flap, and partial necrosis in one flap. The patient with complete necrosis underwent skin grafting at a later date. The wound healed secondarily in case of partial flap necrosis. CONCLUSION Anterior interosseus artery perforator flap must be considered as an important reconstructive option in the armamentarium of the plastic surgeon, while managing hand and wrist defects. PMID:28713704
Propeller flap reconstruction of abdominal defects: review of the literature and case report.
Scaglioni, Mario F; Giuseppe, Alberto Di; Chang, Edward I
2015-01-01
The abdominal wall is perfused anteriorly by the superior and deep epigastric vessels with a smaller contribution from the superficial system. The lateral abdominal wall is perfused predominantly from perforators arising from the intercostal vessels. Reconstruction of soft tissue defects involving the abdomen presents a difficult challenge for reconstructive surgeons. Pedicle perforator propeller flaps can be used to reconstruct defects of the abdomen, and here we present a thorough review of the literature as well as a case illustrating the perforasome propeller flap concept. A patient underwent resection for dermatofibrosarcoma protuberans resulting in a large defect of the epigastric soft tissue. A propeller flap was designed based on a perforator arising from the superior deep epigastric vessels and was rotated 90° into the defect allowing primary closure of the donor site. The patient healed uneventfully and was without recurrent disease 37 months following reconstruction. Perforator propeller flaps can be used successfully in reconstruction of abdominal defects and should be incorporated into the armamentarium of reconstructive microsurgeons already facile with perforator dissections. © 2014 Wiley Periodicals, Inc.
Jang, Hyo Seok; Lee, Young Ho; Kim, Min Bom; Chung, Joo Young; Seok, Hyun Sik; Baek, Goo Hyun
2018-03-01
A skin defect of the hand and wrist is a common manifestation in industrial crushing injuries, traffic accidents or after excision of tumors. We reconstructed a skin defect in the ulnar aspect of the hand and wrist with a perforator-based propeller flap from the ulnar artery. The aims of our study are to evaluate the utility and effectiveness of this flap and to discuss the advantages and disadvantages of the flap in hand and wrist reconstruction with a review of the literature. Between April 2011 and November 2016, five cases of skin defect were reconstructed with a perforator-based propeller flap from the ulnar artery. There were four males and one female. The age of patients ranged from 36 to 73 years. Skin defect sites were on the dorso-ulnar side of the hand in three cases and palmar-ulnar side of the wrist in two cases. The size of the skin defect ranged from 4 × 3 cm to 8 × 5 cm. We evaluated the viability of the flap, postoperative complication and patient's satisfaction. There was no failure of flap in all cases. The size of the flap ranged from 4 × 4 cm to 12 × 4 cm. One patient, who had a burn scar contracture, presented with limited active and passive motion of the wrist after the operation. The other patients had no complications postoperatively. Cosmetic results of the surgery were excellent in one patient, good in three patients, and fair in one patient. The fasciocutaneous propeller flap based on a perforating branch of the ulnar artery is a reliable treatment option for the ulnar side skin defect of the hand and wrist.
Ozcan Akcal, Arzu; Ünal, Kerim; Gorgulu, Tahsin; Akif Akcal, Mehmet; Bigat, Zekiye
2016-10-01
In this report we present two cases of gunshot injury related midfoot defects, reconstructed with a chimeric partial scapula and latissimus dorsi muscle flap and short perforator-based skin flap. The first case, a 14 years old male, had 10 × 8 cm medial plantar and 6 × 4 cm dorsal foot defects and the second case, a 55 years old female, had only 8 × 6 cm dorsal foot defect. In both cases the defects were associated with fractures, one with lateral cuneiform and cuboid with 90% bone loss and the other with navicular bone, respectively. After 6 months, the patients could walk well without support, and radiographs confirmed bony union. A chimeric partial scapula and latissimus dorsi muscle flap and short perforator-based skin flap may be used for the reconstruction of combined bony and soft tissue defects of the midfoot and to promote bone healing. © 2016 Wiley Periodicals, Inc. Microsurgery 36:598-603, 2016. © 2016 Wiley Periodicals, Inc.
Pre-expanded Intercostal Perforator Super-Thin Skin Flap.
Liao, Yunjun; Luo, Yong; Lu, Feng; Hyakusoku, Hiko; Gao, Jianhua; Jiang, Ping
2017-01-01
This article introduces pre-expanded super-thin intercostal perforator flaps, particularly the flap that has a perforator from the first to second intercostal spaces. The key techniques, advantages and disadvantages, and complications and management of this flap are described. At present, the thinnest possible flap is achieved by thinning the pre-expanded flap that has a perforator from the first to second intercostal spaces. It is used to reconstruct large defects on the face and neck, thus restoring function and cosmetic appearance. Copyright © 2016 Elsevier Inc. All rights reserved.
[Soft tissue defects treated with perforator flaps].
Weum, Sven; de Weerd, Louis; Klein, Steven; Hage, J Joris
2008-01-31
Treatment of soft tissue defects caused by trauma, tumour surgery or pressure sores is a challenge to the reconstructive surgeon. Although contour and function may be restored by tissue transposition, traditional methods often cause significant donor site morbidity. This article describes how increased understanding of vascular anatomy has led to the development of new techniques. The article is based on textbooks of plastic surgery, selected articles and own clinical experience. Pedicled and free perforator flaps represent the latest development in surgical treatment of soft tissue defects. The use of perforator flaps can considerably reduce the disadvantages that are associated with other surgical methods. The use of perforator flaps demands microsurgical skills, but has many advantages. Reliable vascular supply and a good aesthetical result can be combined with minimal donor site morbidity. In many cases this technique may even give sensibility to the reconstructed area.
Bilobed perforator free flaps for combined hemitongue and floor-of-the-mouth defects.
Longo, B; Ferri, G; Fiorillo, A; Rubino, C; Santanelli, F
2013-11-01
Combined hemiglossectomy and floor-of-the-mouth defects need accurate reconstructive planning to restore swallowing and speech function. The aim of this prospective study was to evaluate outcomes of the bilobed design applied to perforator free flaps for combined hemitongue and floor-of-the-mouth defects. Twelve patients with a mean age of 71 years (range, 60-84) addressed to combined hemiglossectomy and floor-of-the-mouth resection and bilobed-shaped perforator free-flap reconstruction were prospectively enrolled. Defects were classified as follows: type 1, including only the anterior mobile portion of the tongue (n = 3); type 2, involving both mobile tongue and tongue base (n = 6); and type 3, including segmental mandibulectomy combined with a type 1 or type 2 defect (n = 3). The Kruskal-Wallis and Bonferroni post hoc tests were used to compare outcomes. Type 1 defects were reconstructed by three anterolateral thigh (ALT) perforator flaps; type 2 defects were reconstructed by four ALT flaps and two vertical deep inferior epigastric perforator flaps; and type 3 defects were restored by three osteocutaneous fibula flaps. Eleven flaps (91.6%) healed uneventfully, while one (8.4%) suffered a small area of skin necrosis whose revision did not compromise functional results. Six patients achieved normal intelligible speech, five had acceptable intelligible speech and one had unintelligible speech (p = 0.356). Swallowing function was considered normal in eight patients and with mild impairment in four (p = 0.178). Cosmesis resulted excellent in seven patients and good in five (p = 0.855). The bilobed-shaped perforator free flaps were shown to be a safe and predictable solution for combined hemitongue and floor-of-the-mouth defects providing optimal aesthetic and functional outcomes. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Sadigh, Parviz L; Chang, Li-Ren; Hsieh, Ching-Hua; Feng, Wen-Jui; Jeng, Seng-Feng
2014-09-01
The trapezius myocutaneous flap is an established reconstructive option in head and neck cases The authors present their experience with 10 trapezius perforator flaps, all raised using a freestyle technique of perforator dissection, to successfully reconstruct both local and distant soft-tissue defects. Ten patients underwent soft-tissue reconstruction using trapezius perforator flaps. After mapping the perforator with a handheld Doppler device at the intersection of a horizontal line drawn 6 to 8 cm inferior to the scapular spine and a vertical line drawn 8 to 9 cm lateral to the midline of the back, perforator flaps were raised in a freestyle fashion, with complete preservation of the trapezius muscle. The flap can be pedicled into local defects or transferred as a free flap. Six flaps were elevated as pedicled flaps and four were transferred as free flaps. Flap size ranged from 6 × 4 cm to 25 × 15 cm. The pedicle length ranged from 4 to 14 cm. The pedicle originated from the dorsal scapular artery. In one case, the authors converted from a pedicled flap to a free flap secondary to insufficient pedicle length. All donor sites were closed directly. The follow-up period ranged from 4 months to 4 years. All of the flaps survived completely with no major complications, and no patients developed any shoulder dysfunction. The trapezius perforator flap is a reliable and versatile reconstructive option that can be used to repair both local and distant soft-tissue defects. The donor-site morbidity is minimal. Therapeutic, IV.
Reliable harvest of a dorsal scapular artery perforator flap by augmenting its perfusion.
Kim, So-Young; Lee, Kyeong-Tae; Mun, Goo-Hyun
2016-02-01
Despite confirmation of a reliable perforasome in the dorsal scapular artery in an anatomic study, a true perforator flap has not been recommended in previous clinical studies because of concerns regarding insufficient perfusion in the distal region. In this report, we present two cases of reconstruction for occipital defects caused by tumor extirpation using pedicled dorsal scapular artery perforator flaps without a muscle component. To secure the perfusion of the dorsal scapular artery perforator flap, inclusion of an additional perforator was attempted for perfusion augmentation. The second dorsal scapular artery perforator was harvested in one case. In an additional case, the sixth dorsal intercostal artery perforator with a branch that directly connected with the dorsal scapular artery within the trapezius muscle was additionally harvested. The flaps survived without any perfusion-related complications, including tip necrosis, and no donor site morbidities were observed. We suggest that a perfusion augmented dorsal scapular artery perforator flap by harvesting multiple perforators could be a safe and useful alternative for reconstructive surgery of head and neck defects. © 2014 Wiley Periodicals, Inc.
Free sural artery perforator flap: An occasional gift in oral cavity reconstruction.
Pease, Natalie L; Davies, Andrew; Townley, William A
2016-07-01
The medial sural artery perforator (MSAP) flap is becoming a popular strategy for reconstructing intraoral defects. We present a case in which no MSAPs were present, however, a perforator-based calf flap was successfully raised on the sural artery and used for tongue reconstruction. A corresponding anatomic study was undertaken to establish if this finding was reproducible. A 58-year-old woman underwent left hemiglossectomy for a squamous cell carcinoma of the tongue. Subsequently, 6 fresh frozen cadaveric limbs were dissected examining the blood supply of the posterior calf skin. The sural artery perforator (SAP) flap successfully reconstructed the defect. Our cadaveric study similarly demonstrated a septocutaneous SAP supplying the posterior calf skin in 1 of 6 limbs. SAPs allow a favorable flap dissection, as opposed to the musculocutaneous course of MSAPs. Our findings provide further evidence of the versatility of the calf donor site. © 2016 Wiley Periodicals, Inc. Head Neck 38: E2454-E2456, 2016. © 2016 Wiley Periodicals, Inc.
Jiang, Taoran; Zhu, Ming; Zan, Tao; Gu, Bin; Li, Qingfeng
2017-08-01
In perforator flap transplantation, dissection of the perforator is an important but difficult procedure because of the high variability in vascular anatomy. Preoperative imaging techniques could provide substantial information about vascular anatomy; however, it cannot provide direct guidance for surgeons during the operation. In this study, a navigation system (NS) was established to overlie a vascular map on surgical sites to further provide a direct guide for perforator flap transplantation. The NS was established based on computed tomographic angiography and augmented reality techniques. A virtual vascular map was reconstructed according to computed tomographic angiography data and projected onto real patient images using ARToolKit software. Additionally, a screw-fixation marker holder was created to facilitate registration. With the use of a tracking and display system, we conducted the NS on an animal model and measured the system error on a rapid prototyping model. The NS assistance allowed for correct identification, as well as a safe and precise dissection of the perforator. The mean value of the system error was determined to be 3.474 ± 1.546 mm. Augmented reality-based NS can provide precise navigation information by directly displaying a 3-dimensional individual anatomical virtual model onto the operative field in real time. It will allow rapid identification and safe dissection of a perforator in free flap transplantation surgery.
Reconstruction of trochanteric pressure sores with pedicled anterolateral thigh myocutaneous flaps.
Wang, Chih-Hsin; Chen, Shih-Yi; Fu, Ju-Peng; Dai, Niann-Tzyy; Chen, Shao-Liang; Chen, Tim-Mo; Chen, Shyi-Gen
2011-05-01
To provide an alternative choice for covering trochanteric pressure sores, we report on a modified pedicle anterolateral thigh (ALT) myocutaneous flap based on the descending branch of the lateral circumflex femoral artery. From August 2007 to January 2010, 20 consecutive patients (10 men and 10 women) underwent 21 pedicled ALT myocutaneous flaps for reconstruction of trochanteric pressure sores. The flap was designed and elevated, resembling the ALT perforator flap including part of the vastus lateralis muscle but without skeletonisation of the perforators. The mean age of patients was 79.4 years (range: 46-103). The mean follow-up period was 13.9 months (range: 3-32). The flaps were 8-21 cm long and 5-11 cm wide. All flaps healed without major complications. All donor sites were closed primarily without skin grafting and showed good aesthetic results. No recurrence was observed. This modified design of pedicled ALT myocutaneous flap without skeletonisation of perforators is a reliable and easily harvested flap for reconstruction of trochanteric pressure sores with limited morbidity. Crown Copyright © 2010. Published by Elsevier Ltd. All rights reserved.
Propeller Perforator Flaps in Distal Lower Leg: Evolution and Clinical Applications
2012-01-01
Simple or complex defects in the lower leg, and especially in its distal third, continue to be a challenging task for reconstructive surgeons. A variety of flaps were used in the attempt to achieve excellence in form and function. After a long evolution of the reconstructive methods, including random pattern flaps, axial pattern flaps, musculocutaneous flaps and fasciocutaneous flaps, the reappraisal of the works of Manchot and Salmon by Taylor and Palmer opened the era of perforator flaps. This era began in 1989, when Koshima and Soeda, and separately Kroll and Rosenfield described the first applications of such flaps. Perforator flaps, whether free or pedicled, gained a high popularity due to their main advantages: decreasing donor-site morbidity and improving aesthetic outcome. The use as local perforator flaps in lower leg was possible due to a better understanding of the cutaneous circulation, leg vascular anatomy, angiosome and perforasome concepts, as well as innovations in flaps design. This review will describe the evolution, anatomy, flap design, and technique of the main distally pedicled propeller perforator flaps used in the reconstruction of defects in the distal third of the lower leg and foot. PMID:22783507
Datli, Asli; Suh, HyunSuk; Kim, Young Chul; Choi, Doon Hoon; Hong, Joon Pio Jp
2017-03-01
The reconstruction of the posterior trunk, especially with large dead spaces, remains challenging. Regional muscle flaps may lack adequate volume and reach. The purpose of this report was to evaluate the efficacy of deepithelialized free-style perforator-based propeller flaps to obliterate defects with large dead space. A total of 7 patients with defects on the posterior trunk with large dead spaces were evaluated. After complete debridement or resection, all flaps were designed on a single perforator adjacent to the defect, deepithelialized, and then rotated in a propeller fashion. Flaps were further modified in some cases such as folding the flap after deepithelialization to increase bulk and to obliterate the dead space. The flap dimension ranged from 10 × 5 × 1 to 15 × 8 × 2.5 cm based on a single perforator. The rotation arch of the flap ranged from 90 to 180 degrees. Uneventful healing was noted in all cases. One case showed latent redness and swelling at 7 months after falling down, which resolved with medication. During the average follow-up of 28 months, there were no other flap and donor site complications. The deepithelialized propeller flap can be used efficiently to obliterate dead spaces in the posterior trunk and retains advantages such as having a good vascular supply, adequate bulk, sufficient reach without tension, and minimal donor site morbidity.
Kim, Jong Gyu
2012-01-01
Background During the planning of a thoracodorsal artery perforator (TDAP) free flap, preoperative multidetector-row computed tomographic (MDCT) angiography is valuable for predicting the locations of perforators. However, CT-based perforator mapping of the thoracodorsal artery is not easy because of its small diameter. Thus, we evaluated 1-mm-thick MDCT images in multiple planes to search for reliable perforators accurately. Methods Between July 2010 and October 2011, 19 consecutive patients (13 males, 6 females) who underwent MDCT prior to TDAP free flap operations were enrolled in this study. Patients ranged in age from 10 to 75 years (mean, 39.3 years). MDCT images were acquired at a thickness of 1 mm in the axial, coronal, and sagittal planes. Results The thoracodorsal artery perforators were detected in all 19 cases. The reliable perforators originating from the descending branch were found in 14 cases, of which 6 had transverse branches. The former were well identified in the coronal view, and the latter in the axial view. The location of the most reliable perforators on MDCT images corresponded well with the surgical findings. Conclusions Though MDCT has been widely used in performing the abdominal perforator free flap for detecting reliable perforating vessels, it is not popular in the TDAP free flap. The results of this study suggest that multiple planes of MDCT may increase the probability of detecting the most reliable perforators, along with decreasing the probability of missing available vessels. PMID:22872839
Abdel-Monem, Kareem; Elshahat, Ahmed; Abou-Gamrah, Sherif; Eldin Abol-Atta, Hossam; Abd Eltawab, Reda; Massoud, Karim
2012-01-01
Reconstruction of a breast after mastectomy using the contralateral lower pole breast flap is an appealing procedure because it uses the tissues that were going to be excised during reduction of the sound breast to achieve symmetry. Literature mentioned that these flaps are supplied by the lower internal mammary artery perforators (IMAPs) with no further details. The aim of this study was to determine the site, size, and number of the 4th and 5th IMAPs by using preoperative color Duplex ultrasound and intraoperative exploration. Twenty breasts in 10 patients who presented for reduction mammoplasty were included in this study. Preoperative color duplex was used to determine IMAPs in the 4th and 5th intercostal spaces. These perforators were localized intraoperatively. Intravenous fluorescein injection was used to determine the perfusion of the lower pole breast flap on the basis of these perforators. Statistically, the 4th IMAPs diameters were significantly larger than the 5th IMAPs diameters (P < .05). The lower pole breast flap was perfused through these perforators. Color Duplex ultrasound is an accurate tool to preoperatively determine the 4th and 5th IMAPs.
Video Capture of Perforator Flap Harvesting Procedure with a Full High-definition Wearable Camera
2016-01-01
Summary: Recent advances in wearable recording technology have enabled high-quality video recording of several surgical procedures from the surgeon’s perspective. However, the available wearable cameras are not optimal for recording the harvesting of perforator flaps because they are too heavy and cannot be attached to the surgical loupe. The Ecous is a small high-resolution camera that was specially developed for recording loupe magnification surgery. This study investigated the use of the Ecous for recording perforator flap harvesting procedures. The Ecous SC MiCron is a high-resolution camera that can be mounted directly on the surgical loupe. The camera is light (30 g) and measures only 28 × 32 × 60 mm. We recorded 23 perforator flap harvesting procedures with the Ecous connected to a laptop through a USB cable. The elevated flaps included 9 deep inferior epigastric artery perforator flaps, 7 thoracodorsal artery perforator flaps, 4 anterolateral thigh flaps, and 3 superficial inferior epigastric artery flaps. All procedures were recorded with no equipment failure. The Ecous recorded the technical details of the perforator dissection at a high-resolution level. The surgeon did not feel any extra stress or interference when wearing the Ecous. The Ecous is an ideal camera for recording perforator flap harvesting procedures. It fits onto the surgical loupe perfectly without creating additional stress on the surgeon. High-quality video from the surgeon’s perspective makes accurate documentation of the procedures possible, thereby enhancing surgical education and allowing critical self-reflection. PMID:27482504
Mohan, Anita T; Zhu, Lin; Sur, Yoo Joon; Morsy, Mohamed; Michalak, Gregory J; Lachman, Nirusha; Rammos, Charalambos K; Saint-Cyr, Michel
2017-04-01
This study aimed to delineate and compare the hot spots and three-dimensional vascular territories of dominant profunda artery perforators in the posterior thigh region, and modifications in flap design are discussed. Twenty-nine posterior thigh flaps were raised in fresh cadaveric specimens, and profunda artery perforators were documented. Dominant perforators were injected with iodinated contrast to assess perforasomes using computed tomographic angiography. Analysis with three-dimensional rendering and volume calculations of perfusion patterns was performed. In total, 316 perforators were mapped and 33 perforators were injected for analysis. The hot spot for dominant perforators was the proximal medial quadrant, 5 to 10 cm from the inferior gluteal crease, with two smaller hot spots in the upper lateral and distal posterior midline. Although 69 percent were musculocutaneous, distal perforators were predominantly septocutaneous in the posterior midline, 5 to 8 cm from the popliteal crease. Proximal perforators were classified into first (most proximal) and second perforators, and their median perforasome was 233 and 286.4 cm, respectively (p = 0.86). There were no significant differences between proximal and distal perforators in perforasome surface areas, percentage areas perfused, and perforasome volumes. Large linking vessel networks were attributed to a broader perforasome and greater overlap between adjacent or distal perforators. Dominant linking vessels and recurrent flow through the subdermal plexus contribute to the robust vascular supply of profunda artery perforator flaps. Posterior thigh region perforator hot spots and their perfusion characteristics can inform the potential limits, orientation, and modifications of flap or skin paddle designs.
Advances in imaging technologies for planning breast reconstruction
Mohan, Anita T.
2016-01-01
The role and choice of preoperative imaging for planning in breast reconstruction is still a disputed topic in the reconstructive community, with varying opinion on the necessity, the ideal imaging modality, costs and impact on patient outcomes. Since the advent of perforator flaps their use in microsurgical breast reconstruction has grown. Perforator based flaps afford lower donor morbidity by sparing the underlying muscle provide durable results, superior cosmesis to create a natural looking new breast, and are preferred in the context of radiation therapy. However these surgeries are complex; more technically challenging that implant based reconstruction, and leaves little room for error. The role of imaging in breast reconstruction can assist the surgeon in exploring or confirming flap choices based on donor site characteristics and presence of suitable perforators. Vascular anatomical studies in the lab have provided the surgeon a foundation of knowledge on location and vascular territories of individual perforators to improve our understanding for flap design and safe flap harvest. The creation of a presurgical map in patients can highlight any abnormal or individual anatomical variance to optimize flap design, intraoperative decision-making and execution of flap harvest with greater predictability and efficiency. This article highlights the role and techniques for preoperative planning using the newer technologies that have been adopted in reconstructive clinical practice: computed tomographic angiography (CTA), magnetic resonance angiography (MRA), laser-assisted indocyanine green fluorescence angiography (LA-ICGFA) and dynamic infrared thermography (DIRT). The primary focus of this paper is on the application of CTA and MRA imaging modalities. PMID:27047790
Choi, Jong Woo; Kim, Young Chul; Oh, Tae Suk; Koh, Kyung S; Jeong, Woo Shik
2017-06-01
Although the perforator free flap is now a standard choice for head and neck reconstruction, problems such as microvascular complications, insufficient volume support for the defect, and fistula formation occur. We revisited a de-epithelialized concept for superficial circumflex iliac artery and anterolateral thigh perforator free flap to overcome these problems. We applied the de-epithelized perforator free flaps in 35 cases among 761 microsurgical head and neck reconstructions and investigated flap characteristics (length gain of pedicle, flap size, and volumetric analysis) and outcomes (flap failure, partial flap necrosis, hematoma, infection, and fistula). Satisfactory results were achieved regarding flap survival, volumetric compensation, and fistula formation. Flaps were transferred successfully in all patients, although 1 patient underwent revisional operation due to venous congestion. Transferred flap volume was significantly higher than the resected tumor volume (p < 0.01), which suggests volume augmentation in the destroyed neck envelope and a protective role against adjuvant radiation. Minor dehiscence and bleeding were seen in two cases, and no other complications were identified. The de-epithelialization concept for perforator free flap is helpful to overcome obstacles related to traditional free flaps in terms of flap survival and volumetric augmentation in head and neck reconstructions. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Abdel-Monem, Kareem; Elshahat, Ahmed; Abou-Gamrah, Sherif; Eldin Abol-Atta, Hossam; Abd Eltawab, Reda; Massoud, Karim
2012-01-01
Objective: Reconstruction of a breast after mastectomy using the contralateral lower pole breast flap is an appealing procedure because it uses the tissues that were going to be excised during reduction of the sound breast to achieve symmetry. Literature mentioned that these flaps are supplied by the lower internal mammary artery perforators (IMAPs) with no further details. The aim of this study was to determine the site, size, and number of the 4th and 5th IMAPs by using preoperative color Duplex ultrasound and intraoperative exploration. Method: Twenty breasts in 10 patients who presented for reduction mammoplasty were included in this study. Preoperative color duplex was used to determine IMAPs in the 4th and 5th intercostal spaces. These perforators were localized intraoperatively. Intravenous fluorescein injection was used to determine the perfusion of the lower pole breast flap on the basis of these perforators. Results: Statistically, the 4th IMAPs diameters were significantly larger than the 5th IMAPs diameters (P < .05). The lower pole breast flap was perfused through these perforators. Conclusion: Color Duplex ultrasound is an accurate tool to preoperatively determine the 4th and 5th IMAPs. PMID:22292100
Chi, Zhenglin; Yang, Peng; Song, Dajiang; Li, Zan; Tang, Liang; Gao, Weiyang; Song, Yonghuan; Chu, Tingang
2017-05-01
To investigate the results of resurfacing completely degloved digits using bilobed innervated radial artery superficial palmar branch (RASPB) perforator flap in a spiral fashion. A detailed anatomic study on 30 adult fresh frozen cadavers preinjected with silicone rubber compound to demarcate arterial anatomy documented locations, numbers, and diameters of arteries and skin perforators with surrounding nerves. The flap-raising procedure was performed using four fresh cadaver specimen. We reviewed the reconstruction of 12 digits by using a bilobed spiraled innervated RASPB free perforator flap after non-replantable degloving injury. Two skin paddles were marked out using standard points of reference. At least two separate cutaneous perforator vessels were identified using a hand-held Doppler and were dissected back to the RASPB in retrograde fashion. The skin paddles were then divided between the two cutaneous perforators to provide two separate paddles with a common vascular supply. The skin paddles were stacked in a spiral fashion on the flap inset, effectively increasing the width of the flap to cover the totally degloved finger while still allowing closure of the primary donor-site. The RASPB was present within the flap in all cadavers. The direct perforator and the musculocutaneous perforator were available in 93.33 and 76.67 %, respectively, with neither of them in 6.67 % of the cases. The constantly present two perforators allowed the design of a new bilobed spiraled innervated radial artery superficial palmar branch perforator flap. We used the proposed flap to reconstruct completely degloved digits in 12 patients (mean age 28.6 years; range 17-35 years). With our proposed flap, no flap failure or re-exploration occurred and the donor site was closed primarily in all cases. All the flaps survived uneventfully. Total active motion ranged from 92° to 140° and 111° to 155° in the cases with and without metacarpophalangeal joint involvement, respectively. The static 2 point discrimination test varied from 6 to 11 mm. All the patients were satisfied with the overall results. The bilobed flap is large enough to cover totally degloved finger defects and contain direct skin perforators, provides a bespoke cover for complex soft tissue defects of completely degloved digits while also improving morbidity and cosmesis of the donor site. Level IV, retrospective series.
Wen, Gen; Wang, Chun-Yang; Chai, Yi-Min; Cheng, Liang; Chen, Ming; Yi-Min, L V
2013-11-01
The complex wound with the exposed hardware and infection is one of the common complications after the internal fixation of the tibia fracture. The salvage of hardware and reconstruction of soft tissue defect remain challenging. In this report, we presented our experience on the use of the distally based saphenous neurocutaneous perforator flap combined with vacuum-assisted closure (VAC) therapy for the coverage of the soft tissue defect and the exposed hardware in the lower extremity with fracture. Between January 2008 and July 2010, seven patients underwent the VAC therapy followed by transferring a reversed saphenous neurocutaneous perforator flap for reconstruction of the wound with exposed hardware around the distal tibia. The sizes of the flaps ranged from 6 × 3 cm to 15 × 6 cm. Six flaps survived completely. Partial necrosis occurred in one patient. There were no other complications of repair and donor sites. Bone healing was achieved in all patients. In conclusion, the reversed saphenous neurocutaneous perfortor flaps combined with the VAC therapy might be one of the options to cover the complex wound with exposed hardware in the lower extremities. © 2013 Wiley Periodicals, Inc.
Dynamic perfusion assessment during perforator flap surgery: an up-to-date
MUNTEAN, MAXIMILIAN VLAD; MUNTEAN, VALENTIN; ARDELEAN, FILIP; GEORGESCU, ALEXANDRU
2015-01-01
Flap monitoring technology has progressed alongside flap design. The highly variable vascular anatomy and the complexity associated with modern perforator flaps demands dynamic, real-time, intraoperative information about the vessel location, perfusion patterns and flap physiology. Although most surgeons still assess flap perfusion and viability based solely on clinical experience, studies have shown that results may be highly variable and often misleading. Poor judgment of intraoperative perfusion leads to major complications. Employing dynamic perfusion imaging during flap reconstruction has led to a reduced complication rate, lower morbidity, shorter hospital stay, and an overall better result. With the emergence of multiple systems capable of intraoperative flap evaluation, the purpose of this article is to review the two systems that have been widely accepted and are currently used by plastic surgeons: Indocyanine green angiography (ICGA) and dynamic infrared thermography (DIRT). PMID:26609259
Park, Sun-June; Lee, Kyeong-Tae; Jeon, Byung-Joon; Woo, Kyong-Je
2018-04-01
Pedicled perforator flaps (PPFs) have been widely used to treat pressure sores in the gluteal region. Selection of a reliable perforator is crucial for successful surgical treatment of pressure sores using PPFs. In this study, we evaluate the role of magnetic resonance imaging (MRI) in planning PPF reconstruction of pressure sores in the gluteal region. A retrospective chart review was performed in patients who had undergone these PPF reconstructions and who had received preoperative MRI. Preoperatively, the extent of infection and necrotic tissue was evaluated using MRI, and a reliable perforator was identified, considering the perforator location in relation to the defect, perforator size, and perforator courses. Intraoperatively, the targeted perforator was marked on the skin at the locations measured on the MRI images, and the marked location was confirmed using intraoperative handheld Doppler. Superior gluteal artery, inferior gluteal artery, or parasacral perforators were used for the PPFs. Surgical outcomes were evaluated. A total of 12 PPFs were performed in 12 patients. Superior gluteal artery perforator flaps were performed in 7 patients, inferior gluteal artery perforator flaps were performed in 3 patients, and parasacral perforator flaps were performed in 2 patients. We could identify a reliable perforator on MRI, and it was found at the predicted locations in all cases. There was only one case of partial flap necrosis. There was no recurrence of the pressure sores during the mean follow-up period of 6.7 months (range = 3-15 months). In selected patients with gluteal pressure sores, MRI is a suitable means for not only providing information about disease extent and comorbidities but also for evaluating perforators for PPF reconstructions.
Lefèvre, M; Sarfati, B; Honart, J-F; Alkashnam, H; Rimareix, F; Leymarie, N; Kolb, F
2017-02-01
The musculocutaneous tensor fascia latae flap was one of the first free flaps described. It is possible to harvest a flap with the same skin paddle, vascularized by a septo-cutaneous perforator running through the tensor fascia lata muscle septum and coming from the ascending branch of the lateral circumflex femoral artery. The DIEP is currently the workhorse of autologous breast reconstruction, but there are some contraindications. The septo-cutaneous tensor fascia latae perforator flap may be an alternative for women with lateral upper thigh lipodystrophy. Between 2010 and 2014, three flaps have been performed in two patients for delayed breast reconstruction (one case of unilateral reconstruction, and one bilateral). Perforators were identified by preoperative angiography. The intervention was performed in a two-team approach, in only one operative position. Perforators were located in the horizontal axis of the upper rim of the pubis bone. One perforator artery was dissected for each flap. The mean caliber of the pedicle was 2.8mm, and the mean length was 6.4cm. The operative time was 240minutes for unilateral flap, 375minutes for bilateral flap. There was no case of total or partial necrosis, or complications on the donor site. Cosmetic results were considered satisfying by patients and surgeons with the reconstructed breast as well as the donor site. Septo-cutaneous fascia lata perforator flap is an attractive flap for breast reconstruction in patients with DIEP contraindication and lateral upper thigh lipodystrophy. It has many advantages: easy to harvest, length and calibre of the pedicle, double team approach, only one operating position, quality of reconstruction. It is necessary to carry out a larger series of cases to study the complication rate in the donor site. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Casey, William J; Connolly, Katharine A; Nanda, Alisha; Rebecca, Alanna M; Perdikis, Galen; Smith, Anthony A
2015-03-01
The reliability of deep inferior epigastric artery perforator (DIEP) flap reconstruction following abdominal liposuction is controversial. The authors' early cases were technically successful; however, they experienced high partial flap loss and fat necrosis rates. The authors sought to compare DIEP flap outcomes in the setting of prior liposuction after the use of intraoperative indocyanine green angiography compared to when flaps were assessed on clinical grounds alone. A retrospective review of a consecutive series of DIEP flaps following liposuction at a single institution was performed, comparing those evaluated on clinical grounds alone and those in which indocyanine green angiography was used intraoperatively. Outcomes measured included anastomotic complications, total flap loss, partial flap loss, fat necrosis, and postoperative abdominal wounds. Thirteen DIEP flaps following prior liposuction were performed on 11 patients from July of 2003 through January of 2014. All patients had preoperative imaging with duplex ultrasound or computed tomographic angiography to analyze perforator suitability before surgical exploration. Seven flaps were evaluated intraoperatively on clinical grounds alone. Six flaps were assessed and modified based on indocyanine green angiography. All flaps were successful; however, partial flap loss and fat necrosis rates dropped from 71.4 percent to 0 percent when indocyanine green angiography was used intraoperatively (p = 0.02). Indocyanine green angiography is an excellent vascular imaging modality for intraoperative use to assess flap perfusion, and improves outcomes in DIEP flaps when harvested after prior abdominal suction lipectomy.
[Repair of soft tissue defect in hand or foot with lobulated medial sural artery perforator flap].
Fengjing, Zhao; Jianmin, Yao; Xingqun, Zhang; Liang, Ma; Longchun, Zhang; Yibo, Xu; Peng, Wang; Zhen, Zhu
2015-11-01
To explore the clinical effect of the lobulated medial sural artery perforator flap in repairing soft tissue defect in hand or foot. Since March 2012 to September 2014, 6 cases with soft tissue defects in hands or feet were treated by lobulated medial sural artery flaps pedicled with 1st musculo-cutaneous perforator and 2st musculo-cutaneous perforator of the medial sural artery. The size of the flaps ranged from 4.5 cm x 10.0 cm to 6.0 cm x 17.0 cm. 5 cases of lobulated flap survived smoothly, only 1 lobulated flap had venous articulo, but this flap also survived after the articulo was removed by vascular exploration. All flaps had desirable appearance and sensation and the two-point discrimination was 6 mm in mean with 4 to 12 months follow-up (average, 7 months). Linear scar was left in donor sites in 3 cases and skin scar in 3 cases. There was no malfunction in donor sites. Lobulated medial sural artery perforator flap is feasible and ideal method for the treatment of soft tissue defect in hand or foot with satisfactory effect.
Kim, Sung Young; Rah, Dong Kyun; Chong, Yosep; Lee, Song Hyun; Park, Tae Hwan
2016-10-01
The use of bilirubin, a well-known and powerful antioxidant, has gained popularity in recent years because of its role in the prevention of ischaemic heart disease in patients with Gilbert's syndrome. We investigate the effects of bilirubin on ischaemia-reperfusion (I/R) injury using a rat perforator flap model. Forty-eight rats were randomly divided into two groups: experimental (bilirubin) group (n = 24) and control group (n = 24). In each group, elevated bilateral deep inferior epigastric perforator (DIEP) flaps were created. The right (no ischaemia side) and left (ischaemia side) DIEP flaps were separated according to the presence of ischaemia induction. Ischaemia was induced in anaesthetised rats by perforator clamping for 15 or 30 minutes. After surgery, the flap survival was assessed daily on postoperative days 0 to 5, and overall histological changes of DIEP flaps above the perforator were analysed at postoperative day 5. The flap survival rate in the bilirubin group was significantly higher than that in the control group at the ischaemia side following perforator clamping for 15 or 30 minutes (93·42 ± 4·48% versus 89·63 ± 3·98%, P = 0·002; and 83·96 ± 4·23% versus 36·46 ± 6·38%, P < 0·001, respectively). The difference in flap survival between the two groups was the most prominent on the ischaemic side following 30 minutes of perforator clamping. From a morphologic perspective, pre-treatment with bilirubin was found to alleviate perforator flap necrosis caused by I/R injury in this experimental rat model. © 2015 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Surgical therapy of vulvar cancer: how to choose the correct reconstruction?
2016-01-01
Objective To create a comprehensive algorithmic approach to reconstruction after vulvar cancer ablative surgery, which includes both traditional and perforator flaps, evaluating anatomical subunits and shape of the defect. Methods We retrospectively reviewed 80 cases of reconstruction after vulvar cancer ablative surgery, performed between June 2006 and January 2016, transferring 101 flaps. We registered the possibility to achieve the complete wound closure, even in presence of very complex defects, and the postoperative complications. On the basis of these experience, analyzing the choices made and considering the complications, we developed an algorithm to help with the selection of the flap in vulvoperineal reconstruction after oncologic ablative surgery for vulvar cancer. Results We employed eight types of different flaps, including 54 traditional fasciocutaneous V-Y flaps, 23 rectus abdominis myocutaneous flaps, 11 anterolateral thigh flaps, three V-Y gracilis myocutaneous flaps, three free style perforators V-Y flaps from the inner thigh, two Limberg flaps, two lotus flaps, two deep inferior epigastric artery perforator flap, and one superficial circumflex iliac artery perforator flap. The structures most frequently involved in resection were vulva, perineum, mons pubis, groins, vagina, urethra and, more rarely, rectum, bladder, and lower abdominal wall. Conclusion The algorithm we implemented can be a useful tool to help flap selection. The key points in the decision-making process are: anatomical subunits to be covered, overall shape and symmetry of the defect and some patient features such as skin laxity or previous radiotherapy. Perforator flaps, when feasible, must be considered standard in vulvoperineal reconstruction, although in some cases traditional flaps remain the best choice. PMID:27550406
Bekara, Farid; Herlin, Christian; Somda, Serge; de Runz, Antoine; Grolleau, Jean Louis; Chaput, Benoit
2018-01-01
Currently, increasingly reconstructive surgeon consider the failure rates of perforator propeller flaps especially in the distal third of the lower leg are too important and prefer to return to the use of free flap at first line option with failure rates frequently lower than 5%. So, we performed a systematic review with meta-analysis comparing free flaps (perforator-based or not) and pedicled-propeller flaps to respond to the question "what is the safest coverage for distal third of the lower limb?" This review was conducted according to PRISMA criteria. From 1991 to 2015, MEDLINE®, Pubmed central, Embase and Cochrane Library were searched. The pooled estimations were performed by meta-analysis. The homogeneity Q statistic and the I 2 index were computed. We included 36 articles for free flaps (1,226 flaps) and 19 articles for pedicled-propeller flaps (302 flaps). The overall failure rate was 3.9% [95%CI:2.6-5.3] for free flaps and 2.77% [95%CI:0.0-5.6] for pedicled-propeller flaps (P = 0.36). The complication rates were 19.0% for free flaps and 21.4% for pedicled-propeller flaps (P = 0.37). In more detail, we noted for free flaps versus pedicled-propeller flaps: partial necrosis (2.70 vs. 6.88%, P = 0.001%), wound dehiscence (2.38 vs. 0.26%, P = 0.018), infection (4.45 vs. 1.22%, P = 0.009). The coverage failure rate was 5.24% [95%CI:3.68-6.81] versus 2.99% [95%CI:0.38-5.60] without significant difference (P = 0.016). In the lower limb the complications are not rare and many teams consider the free flaps to be safer. In this meta-analysis we provide evidence that failure and overall complications rate of perforator propeller flaps are comparable with free flaps. Although, partial necrosis is significantly higher for pedicled-propeller flaps than free flaps, in reality the success of coverage appears similar. © 2016 Wiley Periodicals, Inc. Microsurgery, 38:109-119, 2018. © 2016 Wiley Periodicals, Inc.
Multiple-digit resurfacing using a thin latissimus dorsi perforator flap.
Kim, Sang Wha; Lee, Ho Jun; Kim, Jeong Tae; Kim, Youn Hwan
2014-01-01
Traumatic digit defects of high complexity and with inadequate local tissue represent challenging surgical problems. Recently, perforator flaps have been proposed for reconstructing large defects of the hand because of their thinness and pliability and minimal donor site morbidity. Here, we illustrate the use of thin latissimus dorsi perforator flaps for resurfacing multiple defects of distal digits. We describe the cases of seven patients with large defects, including digits, circumferential defects and multiple-digit defects, who underwent reconstruction with thin latissimus dorsi perforator flaps between January 2008 and March 2012. Single-digit resurfacing procedures were excluded. The mean age was 56.3 years and the mean flap size was 160.4 cm(2). All the flaps survived completely. Two patients had minor complications including partial flap loss and scar contracture. The mean follow-up period was 11.7 months. The ideal flap for digit resurfacing should be thin and amenable to moulding, have a long pedicle for microanastomosis and have minimal donor site morbidity. Thin flaps can be harvested by excluding the deep adipose layer, and their high pliability enables resurfacing without multiple debulking procedures. The latissimus dorsi perforator flap may be the best flap for reconstructing complex defects of the digits, such as large, multiple-digit or circumferential defects, which require complete wrapping of volar and dorsal surfaces. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Basterzi, Yavuz; Tenekeci, Goktekin
2016-04-01
Several options have been reported for the reconstruction of myelomeningocele defects. In this article, we present our experience on soft tissue reconstruction of myelomeningocele defects by using island propeller dorsal intercostal artery perforator (DIAP) flaps. Between January 2008 and February 2014, all newborns with large myelomeningocele defects (13 newborns) were reconstructed with island propeller DIAP flaps. All flaps survived completely. In 8 patients out of 13, venous insufficiency was observed which then resolved spontaneously. Flap donor sites were closed primarily. Myelomeningocele defects with a diameter larger than 5 cm require reconstruction with flaps. To mobilize a well-vascularized tissue over the defect without tension in which the suture lines will not overlap over the midline where the dura is repaired and over the meninges is one of the goals of reconstruction for such defects. Perforator propeller flaps enable us to reach those goals. Use of perforator flaps provides 2 important advantages, namely, more predictability and also more freedom in mobilizing flaps toward the defect. This study proves the reliability of DIAP propeller flaps in the reconstruction of myelomeningocele defects.
Tenekeci, Goktekin; Basterzi, Yavuz
2017-01-01
Reconstruction of large myelomeningocele defects using extended (elongated beyond the lateral margin of the latissimus dorsi muscle) dorsal intercostal artery perforator (DICAP) propeller flaps is not recommended by previous studies. However, to provide tension-free and successful closure of a defect, the DICAP propeller flaps must sometimes be elongated beyond this margin. Our experience and results in this issue are discussed. In this article, reconstruction of 11 consecutive cases, with large myelomeningocele defects in which standard DICAP propeller flaps were incapable to close the defect, was achieved using extended DICAP propeller flaps between June 2013 and November 2015. At least two reliable perforators of the neighboring intervertebral spaces are included to supply the flap. Intramuscular dissection of perforators is performed to free the perforators from the surrounding muscle and to gain pedicle length as much as possible to prevent twisting and vascular compromise. All the flaps survived completely except for one patient who had superficial skin necrosis on the most distal part of the flap and had severe accompanying systemic disorders and died on postoperative 14th day. In 7 of 11 patients, venous congestion was noted, which resolved spontaneously. No hematoma or seroma formation was observed during the postoperative follow-up period. Dissection of multiple DICAPs supplying flaps enable us to harvest larger DICAP flaps possibly by providing better arterial supply and venous drainage. We use microsurgical instruments and 4.3× loupe magnification for pedicle dissection in this newborn population. This study shows the reliability of extended DICAP propeller flaps when multiple perforators at sixth or more cranial adjacent intercostal spaces are included in DICAP propeller flaps. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
The perforator pedicled propeller (PPP) flap method: report of two cases.
Hyakusoku, Hiko; Ogawa, Rei; Oki, Koichiro; Ishii, Nobuaki
2007-10-01
Perforator flaps are thin free-tissue transfers consisting of skin and subcutaneous tissue which have the advantage of decreasing donor site morbidity. We have reconstructed postburn scar contractures using "propeller flaps" of the remaining healthy skin around the recipient sites. In this paper, we report on two cases and describe the concept of using "perforator flaps" and "propeller flaps" together as what are called "perforator pedicled propeller (PPP) flaps." Patient 1 was an 18-year-old man with a sacral pressure ulcer. The soft tissue defect was reconstructed with a rotated superior gluteal artery PPP flap. Patient 2 was a 53-year-old woman who presented with an open fracture of the right elbow. The skin defect over the fracture was covered with a rotated deep brachial artery PPP flap raised on the lateral upper arm. The PPP flaps are useful for burn reconstruction and repairing various types of wound. Moreover, microsurgery is unnecessary. The PPP flap may be classified into two types: the central axis type and the acentric axis type. The central axis PPP flap is significant when used as a 90-degree-rotation island flap, and the acentric axis PPP flap is significant when used as a 180-degree-rotation island flap. Both types are easy to harvest and useful for repairing various kinds of wound.
Weum, Sven; Mercer, James B; de Weerd, Louis
2016-07-15
The current gold standard for preoperative perforator mapping in breast reconstruction with a DIEP flap is CT angiography (CTA). Dynamic infrared thermography (DIRT) is an imaging method that does not require ionizing radiation or contrast injection. We evaluated if DIRT could be an alternative to CTA in perforator mapping. Twenty-five patients scheduled for secondary breast reconstruction with a DIEP flap were included. Preoperatively, the lower abdomen was examined with hand-held Doppler, DIRT and CTA. Arterial Doppler sound locations were marked on the skin. DIRT examination involved rewarming of the abdominal skin after a mild cold challenge. The locations of hot spots on DIRT were compared with the arterial Doppler sound locations. The rate and pattern of rewarming of the hot spots were analyzed. Multiplanar CT reconstructions were used to see if hot spots were related to perforators on CTA. All flaps were based on the perforator selected with DIRT and the surgical outcome was analyzed. First appearing hot spots were always associated with arterial Doppler sounds and clearly visible perforators on CTA. The hot spots on DIRT images were always slightly laterally located in relation to the exit points of the associated perforators through the rectus abdominis fascia on CTA. Some periumbilical perforators were not associated with hot spots and showed communication with the superficial inferior epigastric vein on CTA. The selected perforators adequately perfused all flaps. This study confirms that perforators selected with DIRT have arterial Doppler sound, are clearly visible on CTA and provide adequate perfusion for DIEP breast reconstruction. Retrospectively registered at ClinicalTrials.gov with identifier NCT02806518 .
Central artery perforator propeller flap for nasal and medial canthal defects.
Baltu, Yahya; Uzun, Hakan; Dölen, Utku Can; Özyurtlu, Mustafa
2016-08-01
Non-melanoma skin cancer is the most common type of skin cancer of the nasal dorsum and the medial canthal region, which is caused by chronic sun exposure. Limited adjacent tissue and the need for aesthetically pleasing result make the reconstruction of these regions very challenging. To overcome this challenge, we designed a perforator propeller flap based on the central artery. Between January 2014 and November 2015, we covered the nasal or medial canthal defects of 22 patients with central artery perforator propeller flaps. The mean age of the patients was 60.4 years (range: 47-81 years). The median follow-up period was 7.5 months (range: 2-23 months). The pathological diagnoses were basal cell carcinoma for 14 patients and squamous cell carcinoma for the remaining eight patients. The size of the defects ranged from 2 × 2 to 3.5 × 4 cm, and that of the flaps ranged from 2 × 3.5 to 3.2 × 6 cm. We did not observe any major complications requiring surgery, such as total flap loss, hematoma, or dog-ear deformity. However, venous congestion was seen in five patients and partial flap necrosis (that healed without intervention) in two patients. The central artery perforator propeller flap is a reliable and versatile flap for the reconstruction of the nasal dorsum and medial canthal region. Reconstruction with this flap is a single-stage procedure that can cover large defects without causing dog-ear deformity or eyebrow asymmetry compared with other local flap options. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Surgical technique for reconstruction of the nasal septum: the pericranial flap.
Paloma, V; Samper, A; Cervera-Paz, F J
2000-01-01
We describe a new technique for the surgical reconstruction of large-sized anterior septal perforations based on the pericranial flap. The technique requires a standard open rhinoplasty combined with a pericranial flap harvested after a bicoronal approach and tunnelled to the nasal cavity. We present the case of a man with complete destruction of the nasal septum as a result of chronic cocaine abuse. Surgery resulted in a permanent and complete closure of the perforation. The main advantage of this technique is the use of well-vascularized autogenous tissue and the minimal donor site morbidity. This technique provides a new method to close large nasal perforations. Copyright 2000 John Wiley & Sons, Inc. Head Neck 22: 90-94, 2000.
The Lumbar Artery Perforator Flap: 3-Dimensional Anatomical Study and Clinical Applications.
Bissell, Mary Beth; Greenspun, David T; Levine, Josh; Rahal, William; Al-Dhamin, Ammar; AlKhawaji, Ali; Morris, Steven F
2016-10-01
The lumbar region is a potential donor site for perforator-based rotational or free flaps or as a recipient site for free flaps to obtain coverage for deficits in the sacral region. Because of the lack of consensus regarding the microvascular anatomy of this potential flap site, a robust investigation of the anatomy of this region is required. Three-dimensional reconstructions (n = 6) of the microvasculature of the lumbar region were generated using MIMICS software (Materialise, Belgium) for each of the four paired lumbar vessels. Diameter, course, and pedicle length were recorded for all lumbar artery (LA) perforators. Statistical analysis was performed using SigmaStat 4.0 and graphs were generated using GraphPad Prism 6 Software. Perforators arising from the first pair of LAs are reliably detected along the inferior margin of the 12th rib, extending inferiorly and laterally from the midline while perforators arising from the fourth pair of LA perforate the fascia along a horizontal plane connecting the posterior iliac crests. There are significantly more cutaneous perforators arising from the first (L1) and fourth (L4) pairs of LA than from the second (L2) and third (L3) (mean ± SD: L1, 5.5 ± 1.2; L2, 1.4 ± 0.7; L3, 1.3 ± 0.7; L4, 4.8 ± 1.0; P < 0.05). The average perforator diameter arising from L1 is greater than those arising from L4 (diameter ± SD: L1, 1.2 mm ± 0.2 >L4, 0.8 mm ± 0.2; P < 0.0001). L1 and L4 perforators have longer pedicle lengths than those arising from L2 and L3 (length ± SD: L1, 98.2 mm ± 57.8; L4, 106.1 mm ± 23.3 >L2, 67.5 mm ± 27.4; L3, 78.5 mm ± 30.3; P < 0.05). Perforators arising from the first and fourth LAs arise in a predictable fashion, have adequate pedicle lengths, and are of suitable diameter to support a perforator flap. We present a case to support the potential use of this flap for microvascular breast reconstruction.
Taylor, G Ian; Corlett, Russell J; Dhar, Shymal C; Ashton, Mark W
2011-04-01
Island "perforator flaps" have become state of the art for free-skin flap transfer. Recent articles by Saint-Cyr et al. and Rozen et al. have focused on the anatomical and the clinical territories of individual cutaneous perforating arteries in flap planning, and it is timely to compare this work with our angiosome concept. The angiosome concept, published in 1987, was reviewed and correlated with key experimental and clinical work by the authors, published subsequently at different times in different journals. In addition, new data are introduced to define these anatomical and clinical territories of the cutaneous perforators and to aid in the planning of safe skin flaps for local and free-flap transfer. The anatomical territory of a cutaneous perforator was defined in the pig, dog, guinea pig, and rabbit by a line drawn through its perimeter of anastomotic vessels that link it with adjacent perforators in all directions. The safe clinical territory of that perforator, seen not only in the same range of animals but also in the human using either the Doppler probe or computed tomography angiography to locate the vessels, was found reliably to extend to include the anatomical territory of the next adjacent cutaneous perforator, situated radially in any direction. The data provided by Saint-Cyr et al. and Rozen et al., coupled with the authors' own original work on the vascular territories of the body and their subsequent studies, reinforce the angiosome concept and provide the basis for the design of safe flaps for patient benefit.
Lumbar artery perforators: an anatomical study based on computed tomographic angiography imaging.
Sommeling, Casper Emile; Colebunders, Britt; Pardon, Heleen E; Stillaert, Filip B; Blondeel, Phillip N; van Landuyt, Koenraad
2017-08-01
The free lumbar artery perforator flap has recently been introduced as a potentially valuable option for autologous breast reconstruction in a subset of patients. Up to date, few anatomical studies, exploring the lumbar region as a donor site for perforator- based flaps, have been conducted. An anatomical study of the position of the dominant lumbar artery perforator was performed, using the preoperative computed tomographic angiography images of 24 autologous breast reconstruction patients. In total, 61 dominant perforators were determined, 28 on the left and 33 on the right side. A radiologist defined the position of the perforator as coordinates in an xy-grid. Dominant perforators were shown to originate from the lumbar arteries at the level of lumbar vertebrae three or four. Remarkably, approximately 85% of these lumbar artery perforators enter the skin at 7-10 cm lateral from the midline (mean left 8.6 cm, right 8.2 cm). This study concludes a rather constant position of the dominant perforator. Therefore, preoperative-computed tomographic angiography is not always essential to find this perforator and Doppler ultrasound could be considered as an alternative, thereby carefully assessing all advantages and disadvantages inherent to either of these imaging methods.
Lam, D L; Mitsumori, L M; Neligan, P C; Warren, B H; Shuman, W P; Dubinsky, T J
2012-12-01
Autologous breast reconstructive surgery with deep inferior epigastric artery (DIEA) perforator flaps has become the mainstay for breast reconstructive surgery. CT angiography and three-dimensional image post processing can depict the number, size, course and location of the DIEA perforating arteries for the pre-operative selection of the best artery to use for the tissue flap. Knowledge of the location and selection of the optimal perforating artery shortens operative times and decreases patient morbidity.
Superficial ulnar artery perforator flap.
Schonauer, Fabrizio; Marlino, Sergio; Turrà, Francesco; Graziano, Pasquale; Dell'Aversana Orabona, Giovanni
2014-09-01
Superficial ulnar artery is a rare finding but shows significant surgical implications. Its thinness and pliability make this flap an excellent solution for soft tissue reconstruction, especially in the head and neck region. We hereby report a successful free superficial ulnar artery perforator forearm flap transfer for tongue reconstruction. A 64-year-old man presenting with a squamous cell carcinoma of the left tongue underwent a wide resection of the tumor, left radical neck dissection, and reconstruction of the tongue and the left tonsillar pillar with the mentioned flap. No complications were observed postoperatively. The flap survived completely; no recurrence at 6 months of follow-up was detected. Superficial ulnar artery perforator flap has shown to be a safe alternative to other free tissue flaps in specific forearm anatomic conditions.
Yao, Yuanzhen; Tang, Xiujun; Wang, Dali; Wei, Zairong; Wang, Bo; Deng, Chengliang; Zhang, Ziyang; Jin, Wenhu
2018-02-01
To explore the effectiveness of propeller facial artery perforator flap to repair the defect after resection of skin malignant tumor at upper lip. Between July 2012 and January 2017, 17 cases with skin malignant tumor at upper lip underwent tumor resection and the remained defect was repaired with propeller facial artery perforator flap. Among the 17 patients, 3 were male and 14 were female, with an average age of 57 years (range, 35-82 years). There were 5 cases of squamous cell carcinoma and 12 cases of basal cell carcinoma. The disease duration ranged from 4 months to 11 years with an average of 20 months. The tumor size ranged from 1.4 cm×0.3 cm to 3.1 cm×1.4 cm. The extended resection of the tumor tissue was performed according to the characters of tumor. According to the location, size, and shape of the defect and the position of facial artery perforator explored with Doppler ultrasonography, the propeller facial artery perforator flap was designed to repair the defect and partial donor site. The flap size ranged from 5 cm×2 cm to 7 cm×3 cm. The length of the perforator pedicle was 0.5-1.0 cm with an average of 0.8 cm. The defect at donor site was directly closed. Cyanosis occurred in 3 cases of the distal flap after operation, then healing after symptomatic treatment. The remaining flaps survived successfully and the wound healed by first intention. Primary healing was obtained in the donor site. All the patients were followed up 6-36 months with an average of 18 months. The shape of the patient's upper lip was good and the scar on the donor site was unconspicuous. There was no lip deformity, ala nasi deflection, facial tension, entilation dysfunction, or recurrence of tumor during follow-up. At last follow-up, the results of self-evaluation were very satisfactory in 13 cases and satisfactory in 4 cases. Based on multiple advantages of good blood supply, large rotation range, aesthetic outcome, and slight injury of the donor site, propeller facial artery perforator flap is not only an optimal choice for repairing upper lip defect after resection of skin malignant tumors, but also can achieve good functional and cosmetic effectiveness.
Application of multidetector-row computed tomography in propeller flap planning.
Ono, Shimpei; Chung, Kevin C; Hayashi, Hiromitsu; Ogawa, Rei; Takami, Yoshihiro; Hyakusoku, Hiko
2011-02-01
The propeller flap is defined as (1) being island-shaped, (2) having an axis that includes the perforators, and (3) having the ability to be rotated around an axis. The advantage of the propeller flap is that it is a pedicle flap that can be applied to cover defects located at the distal ends of the extremities. The specific aims of the authors' study were (1) to evaluate the usefulness of multidetector-row computed tomography in the planning of propeller flaps and (2) to present a clinical case series of propeller flap reconstructions that were planned preoperatively using multidetector-row computed tomography. The authors retrospectively analyzed all cases between April of 2007 and April of 2010 at Nippon Medical School Hospital in Tokyo, where multidetector-row computed tomography was used preoperatively to plan surgical reconstructions using propeller flaps. Thirteen patients underwent 16 flaps using the propeller flap technique. The perforators were identified accurately by multidetector-row computed tomography preoperatively in all cases. This is the first report describing the application of multidetector-row computed tomography in the planning of propeller flaps. Multidetector-row computed tomography is superior to other imaging methods because it demonstrates more precisely the perforator's position and subcutaneous course using high-resolution three-dimensional images. By using multidetector-row computed tomography to preoperatively identify a flap's perforators, the surgeon can better plan the flap design to efficiently conduct the flap surgery.
Tenekeci, Goktekin; Basterzi, Yavuz; Unal, Sakir; Sari, Alper; Demir, Yavuz; Bagdatoglu, Celal; Tasdelen, Bahar
2018-04-09
Bilateral rotation flaps are considered the workhorse flaps in reconstruction of myelomeningocele defects. Since the introduction of perforator flaps in the field of reconstructive surgery, perforator flaps have been used increasingly in the reconstruction of various soft tissue defects all over the body because of their appreciated advantages. The aim of this study was to compare the complications and surgical outcomes between bilateral rotation flaps and dorsal intercostal artery perforator (DICAP) flaps in the soft tissue reconstruction of myelomeningocele defects. Between January 2005-February 2017, we studied 47 patients who underwent reconstruction of myelomeningocele defects. Patient demographics, operative data, and postoperative data were reviewed retrospectively and are included in the study. We found no statistically significant differences in patient demographics and surgical complications between these two groups; this may be due to small sample size. With regard to complications-partial flap necrosis, cerebrospinal fluid (CSF) leakage, necessity for reoperation, and wound infection-DICAP propeller flaps were clinically superior to rotation flaps. Partial flap necrosis was associated with CSF leakage and wound infection, and CSF leakage was associated with wound dehiscence. Although surgical outcomes obtained with DICAP propeller flaps were clinically superior to those obtained with rotation flaps, there was no statistically significant difference between the two patient groups. A well-designed comparative study with adequate sample size is needed. Nonetheless, we suggest using DICAP propeller flaps for reconstruction of large myelomeningocele defects.
Application of a new laser Doppler imaging system in planning and monitoring of surgical flaps
NASA Astrophysics Data System (ADS)
Schlosser, Stefan; Wirth, Raphael; Plock, Jan A.; Serov, Alexandre; Banic, Andrej; Erni, Dominique
2010-05-01
There is a demand for technologies able to assess the perfusion of surgical flaps quantitatively and reliably to avoid ischemic complications. The aim of this study is to test a new high-speed high-definition laser Doppler imaging (LDI) system (FluxEXPLORER, Microvascular Imaging, Lausanne, Switzerland) in terms of preoperative mapping of the vascular supply (perforator vessels) and postoperative flow monitoring. The FluxEXPLORER performs perfusion mapping of an area 9×9 cm with a resolution of 256×256 pixels within 6 s in high-definition imaging mode. The sensitivity and predictability to localize perforators is expressed by the coincidence of preoperatively assessed LDI high flow spots with intraoperatively verified perforators in nine patients. 18 free flaps are monitored before, during, and after total ischemia. 63% of all verified perforators correspond to a high flow spot, and 38% of all high flow spots correspond to a verified perforator (positive predictive value). All perfused flaps reveal a value of above 221 perfusion units (PUs), and all values obtained in the ischemic flaps are beneath 187 PU. In summary, we conclude that the present LDI system can serve as a reliable, fast, and easy-to-handle tool to detect ischemia in free flaps, whereas perforator vessels cannot be detected appropriately.
van der Zee, Caroline W; Moerman, Esther; Haverlag, Robert; Schepers, Tim
2015-01-01
The treatment of soft tissue defects of the ankle, combined with an implant-related infection, remains a challenge. The present case report illustrates the use of a pedicled perforator flap for soft tissue reconstruction to cover a postoperative defect at the lateral malleolus after an ankle fracture. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Dusseldorp, Joseph R; Pham, Quy J; Ngo, Quan; Gianoutsos, Mark; Moradi, Pouria
2014-09-01
The medial sural artery perforator (MSAP) flap is a versatile fasciocutaneous flap. The main difficulty encountered when raising the MSAP flap is in obtaining adequate pedicle length during intra-muscular dissection. The objective of this study was to determine the pattern of intra-muscular course of the MSAP flap pedicle. 14 cadaveric specimens were dissected and CT angiograms of 84 legs were examined. The intra-muscular branching pattern and depths of the medial sural artery branches were analyzed. The number of perforators, position of the dominant perforator and both intra-muscular and total pedicle length were also recorded and compared to existing anatomical data. Three types of arterial branching pattern were identified within the medial gastrocnemius, demonstrating one (31%), two (59%) or three or more (10%) main branches. A dominant perforator from the medial sural artery was present in 92% of anatomical specimens (13/14). Vertically, the location of the perforator from the popliteal crease was on average 13 cm (±2 cm). Transversely, the perforator originated 2.5 cm (±1 cm) from the posterior midline. Using CT angiography it was possible in 10 consecutive patients to identify a more superficial intra-muscular branch and determine the leg with the optimal branching pattern type for flap harvest. This study is the first to describe the variability of the intra-muscular arterial anatomy of the medial head of gastrocnemius muscle. Surgeons utilizing the MSAP flap option should be aware of the possible branching pattern types and consequently the differing perforator distribution and depths of intra-muscular branches. Routine use of pre-operative CT angiogram may help determine which leg has the most favorable branching pattern type and intra-muscular course for flap harvest. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Patel, Rajan S; Higgins, Kevin M; Enepekides, Danny J; Hamilton, Paul A
2010-10-01
The anatomic variability of cutaneous perforators contributes to the technical challenges of anterolateral thigh (ALT) free flap harvest. The objective of this study was to assess the accuracy and clinical utility of preoperative colour flow Doppler (CFD) ultrasonography in evaluating planned ALT flap donor sites. A prospective study of the infrainguinal vasculature (profunda femoris and lateral circumflex femoral arteries) in 16 consecutive patients scheduled for ALT free flap transfer for reconstruction of head and neck surgical defects was undertaken. All patients underwent CFD ultrasonography. The location of perforators and the thigh thickness determined by CFD ultrasonography were correlated with the actual intraoperative findings using a scatter plot and paired t-test. Two patients were diagnosed with bilateral silent infrainguinal claudication, which precluded safe use of the ALT donor site. In two other patients, the planned ALT donor site ipsilateral to the defect was not used because of silent infrainguinal claudication diagnosed by CFD ultrasonography. In the 14 patients who underwent ALT flap harvest, CFD ultrasonography identified 48 perforators, which coincided with 43 actual perforators found intraoperatively. CFD ultrasonography demonstrated a statistically significant correlation with the actual perforator locations (Spearman coefficient .76; p = .55). Although CFD ultrasonography tended to underestimate flap thickness, there was a statistically significant correlation (Spearman coefficient .94; p ≤ .0001) with the actual flap thickness. CFD ultrasonography has clinical utility in facilitating decision making and planning ALT flap harvest.
Zhong, Wanrun; Lu, Shengdi; Wang, Chunyang; Wen, Gen; Han, Pei; Chai, Yimin
2017-07-01
The lack of soft tissue that is available for medial leg and foot defect reconstructions presents a challenge for plastic surgeons. The saphenous neurofasciocutaneous perforator flap application presents an effective alternative to local flap transfers. However, the venous flow and pedicle twisting problems are still disputed. Here, we present our experiences with modified cutaneous pedicles with a single perforator pedicle, which improves the venous flow and the pedicle twisting problem. This study was conducted from June 2007 through September 2011, and a total of 15 patients with lower medial leg and foot defects were included. There were 11 men and four women. An asymmetric 'propeller' flap was planned around a perforator that was adjacent to the defects, which was preoperatively confirmed by Doppler. The perforator was sufficiently dissociated to allow for the flap to be turned towards the defects. We preserved some distal skin and subcutaneous tissue from the short side of the 'propeller' to cover some donor site regions, and other regions were covered with split thickness skin grafts. The follow-up period ranged from 3 to 12 months. An infection occurred in one case. Partial flap necrosis was noted in two cases. The other 12 flaps completely survived and matched the recipient sites with regard to colour, texture and thickness. The single perforator greater saphenous neuro-veno-fasciocutaneous propeller flap is an effective solution for medial leg and foot defects, and it has a large rotation arc and a satisfactory aesthetic result. © 2015 Royal Australasian College of Surgeons.
An innovative method of planning and displaying flap volume in DIEP flap breast reconstructions.
Hummelink, S; Verhulst, Arico C; Maal, Thomas J J; Hoogeveen, Yvonne L; Schultze Kool, Leo J; Ulrich, Dietmar J O
2017-07-01
Determining the ideal volume of the harvested flap to achieve symmetry in deep inferior epigastric artery perforator (DIEP) flap breast reconstructions is complex. With preoperative imaging techniques such as 3D stereophotogrammetry and computed tomography angiography (CTA) available nowadays, we can combine information to preoperatively plan the optimal flap volume to be harvested. In this proof-of-concept, we investigated whether projection of a virtual flap planning onto the patient's abdomen using a projection method could result in harvesting the correct flap volume. In six patients (n = 9 breasts), 3D stereophotogrammetry and CTA data were combined from which a virtual flap planning was created comprising perforator locations, blood vessel trajectory and flap size. All projected perforators were verified with Doppler ultrasound. Intraoperative flap measurements were collected to validate the determined flap delineation volume. The measured breast volume using 3D stereophotogrammetry was 578 ± 127 cc; on CTA images, 527 ± 106 cc flap volumes were planned. The nine harvested flaps weighed 533 ± 109 g resulting in a planned versus harvested flap mean difference of 5 ± 27 g (flap density 1.0 g/ml). In 41 out of 42 projected perforator locations, a Doppler signal was audible. This proof-of-concept shows in small numbers that flap volumes can be included into a virtual DIEP flap planning, and transferring the virtual planning to the patient through a projection method results in harvesting approximately the same volume during surgery. In our opinion, this innovative approach is the first step in consequently achieving symmetric breast volumes in DIEP flap breast reconstructions. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Izumi, Ken; Fujikawa, Masakazu; Tashima, Hiroki; Saito, Takuya; Sotsuka, Yohei; Tomita, Koichi; Hosokawa, Ko
2013-11-01
Recent advances in perforator flap surgical techniques have allowed for safe and reliable autologous tissue transfer with minimal donor-site morbidity. Between April 2012 and January 2013, we performed immediate breast reconstruction using free medial circumflex femoral artery perforator (MCFAP) flaps in 15 patients after breast-conserving surgery. The flaps were harvested from patients in the lithotomy position, while a second surgical team simultaneously conducted tumour resection. Of the 15 procedures performed, three flaps were dissected as true perforator flaps, while 12 flaps were dissected as muscle-sparing perforator flaps. The mean flap weight was 138.5 g (range, 77-230 g) and the mean pedicle length was 5.7 cm (range, 3.0-9.0 cm). Recipient vessels for anastomosis were serratus branches in 10 patients, internal mammary vessels in three patients and thoracodorsal vessels in two patients. The mean duration of surgery was 6.74 h (range, 5.65-9.45 h). There were no major complications requiring surgical intervention. Researchers observed partial flap necrosis, which manifested as small firm lesions in two patients, as well as local wound infection and dehiscence in one patient, which resolved spontaneously. There were no instances of donor-site seroma formation or lymphoedema in any of the patients. An objective assessment of postoperative photographs showed that cosmetic results were mostly satisfactory. Donor-site scars along the medial groin crease were inconspicuous and readily concealed by clothing. Given its reliable vascularity and minimal donor-site morbidity, the free MCFAP flap can be a good alternative for partial breast reconstruction after breast-conserving surgery. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Reactive Orthotropic Lattice Diffuser for Noise Reduction
NASA Technical Reports Server (NTRS)
Khorrami, Mehdi R. (Inventor)
2016-01-01
An orthotropic lattice structure interconnects porous surfaces of the flap with internal lattice-structured perforations to equalize the steady pressure field on the flap surfaces adjacent to the end and to reduce the amplitude of the fluctuations in the flow field near the flap end. The global communication that exists within all of the perforations provides the mechanism to lessen the pressure gradients experienced by the end portion of the flap. In addition to having diffusive effects (diffusing the incoming flow), the three-dimensional orthogonal lattice structure is also reactive (acoustic wave phase distortion) due to the interconnection of the perforations.
Park, Sung Woo; Oh, Tae Suk; Eom, Jin Sup; Sun, Yoon Chi; Suh, Hyun Suk; Hong, Joon Pio
2015-05-01
The reconstruction of the posterior trunk remains to be a challenge as defects can be extensive, with deep dead space, and fixation devices exposed. Our goal was to achieve a tension-free closure for complex defects on the posterior trunk. From August 2006 to May 2013, 18 cases were reconstructed with multiple flaps combining perforator(s) and local skin flaps. The reconstructions were performed using freestyle approach. Starting with propeller flap(s) in single or multilobed design and sequentially in conjunction with adjacent random pattern flaps such as fitting puzzle. All defects achieved tensionless primary closure. The final appearance resembled a jigsaw puzzle-like appearance. The average size of defect was 139.6 cm(2) (range, 36-345 cm(2)). A total of 26 perforator flaps were used in addition to 19 random pattern flaps for 18 cases. In all cases, a single perforator was used for each propeller flap. The defect and the donor site all achieved tension-free closure. The reconstruction was 100% successful without flap loss. One case of late infection was noted at 12 months after surgery. Using multiple lobe designed propeller flaps in conjunction with random pattern flaps in a freestyle approach, resembling putting a jigsaw puzzle together, we can achieve a tension-free closure by distributing the tension to multiple flaps, supplying sufficient volume to obliterate dead space, and have reliable vascularity as the flaps do not need to be oversized. This can be a viable approach to reconstruct extensive defects on the posterior trunk. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Blondeel, P N
1999-04-01
The superior and inferior myocutaneous gluteal free flaps have been considered as valuable alternatives to the latissimus dorsi or TRAM flap since 1975. The superior gluteal artery perforator (S-GAP) flap is the ultimate refinement of this myocutaneous flap as no gluteus maximus muscle is harvested. The flap is vascularised by one single perforator originating from the superior gluteal artery. This study summarises the prospectively gathered data on 20 free S-GAP flaps used for breast reconstruction in 16 patients. Immediate reconstruction was performed in six breasts and delayed in 14 breasts. Mean follow-up was 11.1 months. Two risk factors, Raynaud's disease and radiotherapy, were the cause of flap revision in two different patients. Total flap loss occurred in one case. Partial flap loss was not observed and a small area of fat necrosis was diagnosed by mammography in one other patient. All flaps were anastomosed to the internal mammary vessels at the 3rd costochondral junction. The anatomy of the sensate nerves of the S-GAP flap is described. Two nervous repairs provided early sensory recovery. The free S-GAP flap has become my personal second choice for autologous breast reconstruction after the DIEP (deep inferior epigastric perforator) flap. The S-GAP flap is indicated in patients with an asthenic body habitus or with excessive abdominal scarring. The advantages are the abundance of adipose tissue in this area even in thin patients, a long vascular pedicle, a hidden scar, improved projection of the reconstructed breast compared to the DIEP and TRAM flaps and the preservation of the entire gluteus maximus muscle. The donor morbidity is extremely low.
Bekara, Farid; Herlin, Christian; Mojallal, Ali; Sinna, Raphael; Ayestaray, Benoit; Letois, Flavie; Chavoin, Jean Pierre; Garrido, Ignacio; Grolleau, Jean Louis; Chaput, Benoit
2016-01-01
Currently, increased interest in the perforator-pedicled propeller flap should not obscure the fact that it is, in reality, a complex procedure requiring experience and monitoring similar to free flaps. Through a meta-analysis, the authors aimed to identify the risk factors of perforator-pedicled propeller flap failure in lower extremity defects. The MEDLINE, PubMed Central, Embase, and Cochrane databases were searched from 1991 to May of 2014 for articles describing perforator-pedicled propeller flaps in the lower extremity. The study selection met the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. Fixed-effects models were used. Forty articles complied with the inclusion criteria, representing 428 perforator-pedicled propeller flaps. The most common cause was posttraumatic (55.2 percent). Most of the defects were at the distal third of the lower leg (45.6 percent). The arc of rotation was 180 degrees for 34.3 percent. Complications were found in 25.2 percent, including partial necrosis (10.2 percent) and complete necrosis (3.5 percent). Complete flap survival was found in 84.3 percent. The authors identified three significant risk factors: age older than 60 years (relative risk, 1.61; p = 0.03), diabetes (relative risk, 2.00; p = 0.02), and arteriopathy (relative risk, 3.12; p = 0.01). No significant results were found regarding smoking status other than a tendency (p = 0.06), acute cause (p = 0.59), posttraumatic cause (p = 0.97), distal third of the lower leg (p = 0.66), fascia inclusion (p = 0.70), and pedicle rotation greater than 120 degrees (p = 0.41). Age older than 60 years, diabetes, and arteriopathy are significant risk factors of perforator-pedicled propeller flap complications in the lower extremity. Risk, IV.
[Antegrade extended peroneal artery perforator flap for knee reconstruction].
Ruan, Hongjiang; Cai, Peihua; Fan, Cunyi; Chai, Yimin; Liu, Shenghe
2009-03-01
To investigate the operative technique and clinical results of repairing the soft tissue defects of knee with antegrade extended peroneal artery perforator flap. From October 2007 to January 2008, 3 patients (2 men and 1 woman) with the soft tissue defects of knee were treated, with the ages of 18, 31 and 42 years, respectively. The first case sustained femur and pelvis fractures and soft tissue defect over his right popliteal fossa, which were treated with open reduction and internal fixation (ORIF) and debridement of knee joint 2 weeks ago. The second case was necrosis of skin 3 weeks after ORIF for fracture of tibial plateau. The third case suffered from open fracture of tibial plateau and soft tissue defect, which were treated with external fixation and debridement 3 weeks ago. The defect sizes were 16 cm x 9 cm, 11 cm x 6 cm and 14 cm x 7 cm. The flap was raised by dividing the peroneal artery and veins distally and elevating them proximally, which covered for the defects of knee. The flaps were designed with the size of 18 cm x 10 cm, 12 cm 7 cm and 15 cm x 8 cm. The pure vascular pedicle of the flap was 10 cm to 17 cm in length, including the peroneal vessels and one or two perforator branches. The donor site is covered by a split thickness skin graft. All flaps survived after surgery. The donor sites healed by first intention and the skin grafts survived. After following up for 6, 8 and 11 months, the appearance and function of the flaps were all satisfactory. Based on the modified HSS knee performance system, post-operative knee functional outcomes of three patients were excellent. The antegrade extended peroneal artery perforator flap supplied by a pure vascular pedicle can be a good alternative for reconstruction of knee. The flap, with a long and thin pure vascular pedicle, could provide good texture and contour matching the recipient area.
Early experience with the free lumbar artery perforator flap for breast reconstruction.
Peters, Kevin T; Blondeel, Phillip N; Lobo, Fernando; van Landuyt, Koenraad
2015-08-01
Autologous breast reconstruction has become a progressively more popular method of breast reconstruction. A wide variety of perforator flaps have been described and subsequently refined to decrease donor-site morbidity. Recently, the lumbar artery perforator (LAP) flap has been reported as an option for autologous breast reconstruction. This study summarises the prospectively gathered data of 35 free LAP flaps for breast reconstruction in 28 patients. The mean follow-up was 18 months. The internal mammary artery and the venae comitantes were used as recipient vessels in all reconstructions. In 80% of the reconstructions (28 flaps), an interposition graft was used. Six flaps (17%) had to be revised for venous thrombosis. Two of the revised flaps (5.7%) could not be salvaged, and total flap necrosis occurred. The mean operating time was 6 h and 15 min, 6 h and 39 min when an interposition graft was used and 5 h and 23 min when no interposition graft was necessary. The LAP flap should be considered as a further alternative for breast reconstruction in patients in whom a deep inferior epigastric artery perforator (DIEAP) flap is not possible or not desirable. Shaping of this flap is easier compared to any other flaps due to the quality of the lumbar fat and the gluteal extension. An interposition graft is frequently used to facilitate anastomosis, either to lengthen the pedicle or to resolve size mismatch. This is a disadvantage of the LAP flap. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Huang, Jen-Wu; Huang, Chih-Sheng; Shih, Yu-Chung; Perng, Cherng-Kang; Lin, Yi-Ying; Wu, Szu-Hsien
2018-06-01
The endoscopic technique has been utilized to harvest muscle flaps and detect perforators of fasciocutaneous flaps. This study aimed to compare the perioperative outcomes between the endoscope-assisted technique and handheld acoustic Doppler for perforator identification in fasciocutaneous flaps.This retrospective case-control study included patients who underwent fasciocutaneous flap reconstruction for traumatic soft tissue defects. In the case group, perforator identification was assisted by the endoscope-assisted technique. In the control group, age- and sex-matched patients received handheld acoustic Doppler to detect perforators. Perioperative outcomes, flap characteristics, and postoperative complications were compared.There were 12 patients in the case group and 12 in the control group. Compared with the control group, the case group had a significantly shorter length of donor-site wounds (9 cm vs 12 cm, P = .023) and a significantly smaller proportion of patients receiving skin grafting at the donor sites (0% vs 41.7%, P = .037). The case group had a longer operative time, but the difference was not statistically significant (180 minutes vs 150 minutes, P = .367). The amount of blood loss, the time length of postoperative drainage, and complications did not significantly differ between the 2 groups.The endoscope-assisted technique for perforator identification of fasciocutaneous flaps provided less donor-site morbidity and a significantly shorter length of donor-site wounds than the conventional handheld acoustic Doppler, which suggests that this technique could be a valuable alternative when a precise design is indicated.
Lazzeri, Davide; Huemer, Georg M.; Nicoli, Fabio; Larcher, Lorenz; Dashti, Talal; Grassetti, Luca; Li, Qingfeng; Spinelli, Giuseppe; Agostini, Tommaso
2013-01-01
Background The aim of this investigation was to systematically review the current literature to provide the best data for indications, outcomes, survival, and complication rates of pedicled propeller perforator flaps for upper body defects. Methods A comprehensive literature review for articles published from January 1991 to December 2011 was performed using the PubMed, Medline, and Cochrane Databases. Articles without available full-text, single case reports or papers with excessive missing data were excluded. Papers reporting pedicle-perforator (propeller) flaps used for lower extremity reconstruction were excluded from meta-analysis. Results From the initial 1,736 studies our search yielded, 343 studies qualified for the second stage of selection. Of 117 full-text reports screened, 41 studies, met the definitive inclusion and exclusion criteria. Of the selected 41 articles, 26 were case series, original papers or retrospective reviews and were included, whereas 15 were case report papers and therefore were excluded. Two hundred ninety-five propeller flaps were reported to have been used in a total of 283 patients. Indications include repair of trauma-induced injuries, post-trauma revision surgery, cancer resection, chronic infection, pressure sores, and chronic ulcers with a major complication rate (3.3%) comparable to that of free flaps. No specific exclusion criteria for the procedure were presented in the studies reviewed. Conclusions Pedicled propeller flaps are a versatile and safe reconstructive option that are easy and quick to raise and that provide unlimited clinical solutions because of the theoretical possibility of harvesting them based on any perforator chosen among those classified in the body. PMID:23362479
Balakrishnan, Thalaivirithan Margabandu; Ramkumar, Jayagosh; Jaganmohan, Janardhanan
2017-01-01
Lower third leg soft tissue defects with anatomical and pathological constraints are posing formidable challenges to reconstructive surgeon. This retrospective study was conducted to assess the effectiveness of ad hoc posterior tibial vessels perforator-propeller flaps for the reconstruction of small and medium sized soft tissue defects in the lower third leg. 22 patients (16 were males and 6 were females) were involved in this study between period of January 2012 and December 2016.We followed the protocol of initial non delineating exploratory incision made to find out single best perforator in all patients. All the defects in leg reconstructed with adhoc posterior tibial vessel propeller flaps. All 22 flaps survived well. All in an average of 13 months follow up period, had pain free walking, with minimal scarring and acceptable aesthesis at the reconstruction sites with no need for any secondary procedure. With inability of preoperatively dopplering the perforators in the lower third leg region, the exploratory posterior nondelineating incision was used in all cases to secure the single best perforator for the propeller flaps. Thus adhoc posterior tibial vessel propeller flaps are dependable, easily adoptable for the reconstruction of soft tissue defects of the lower third leg region.
Balakrishnan, Thalaivirithan Margabandu; Ramkumar, Jayagosh; Jaganmohan, Janardhanan
2017-01-01
Introduction: Lower third leg soft tissue defects with anatomical and pathological constraints are posing formidable challenges to reconstructive surgeon. Aim: This retrospective study was conducted to assess the effectiveness of ad hoc posterior tibial vessels perforator-propeller flaps for the reconstruction of small and medium sized soft tissue defects in the lower third leg. Patients and Methods: 22 patients (16 were males and 6 were females) were involved in this study between period of January 2012 and December 2016.We followed the protocol of initial non delineating exploratory incision made to find out single best perforator in all patients. All the defects in leg reconstructed with adhoc posterior tibial vessel propeller flaps. Results: All 22 flaps survived well. All in an average of 13 months follow up period, had pain free walking, with minimal scarring and acceptable aesthesis at the reconstruction sites with no need for any secondary procedure. Conclusion: With inability of preoperatively dopplering the perforators in the lower third leg region, the exploratory posterior nondelineating incision was used in all cases to secure the single best perforator for the propeller flaps. Thus adhoc posterior tibial vessel propeller flaps are dependable, easily adoptable for the reconstruction of soft tissue defects of the lower third leg region. PMID:29618863
Hai, Henglin; Li, Huatao; Chen, Yang; Li, Qiang; Wu, Shenggang; Lili, Wang; Yan, Lei; Xiaoying, Zhou
2013-03-01
To investigate the effectiveness of pedicled superior gluteal artery perforator bilateral quadrilobed flaps for repairing large sacrococcygeal pressure sores. Between June 2003 and August 2011, 6 paraplegia patients with large sacrococcygeal pressure sores were repaired with the pedicled superior gluteal artery perforator bilateral quadrilobed flaps. There were 2 males and 4 females with an average age of 45.6 years (range, 37-62 years). The mean disease duration was 8.4 months (range, 3-26 months). According to National Pressure Ulcer Advisory Panel (NPUAP) standard, 6 cases rated as degree IV. The size of pressure sores ranged from 15 cm x 13 cm to 18 cm x 16 cm. The size of flaps ranged from 18 cm x 14 cm to 21 cm x 15 cm. After operation, all flaps survived successfully. The wounds healed by first intention in 5 cases; partial dehiscence of incision occurred in 1 case, which was cured after dressing change for 26 days. Six patients were followed up 6-24 months (mean, 12.5 months). The appearance and texture of the flaps were smooth and soft with good elasticity and no ulceration. Pedicled superior gluteal artery perforator bilateral quadrilobed flaps can repair large sacrococcygeal pressure sores. The appearance of flaps is smooth and has good compression-resistance effect.
Zhou, Xiao; Wang, Jin; Qiang, Li; Rui, Yongjun; Xue, Mingyu
2018-04-01
The anterolateral thigh (ALT) flap plays an essential part in plastic and reconstructive surgery. However, repair of the anterolateral donor site has not been the focus of the clinicians.To assess the clinical value and feasibility of using a modified anteromedial thigh (AMT) perforator flap for repairing the ALT free flap donor site.In this retrospective study, 16 ALT flaps were transferred to resurface large soft-tissue defects (ranged from 7 × 5 to 13 × 8 cm) in the foot or hand from June 2012 to March 2013. The donor sites were repaired with an advancement flap pedicled with an AMT perforator. Sensation within the advancement flap, return-to-work (RTW) time, the aesthetic appearance of the donor sites, and functional recovery were measured.All 15 flaps survived completely without necrosis. One flap developed partial necrosis in the tip but healed with dressing changes after 1 week. The medain follow-up period was 3.5 months (range, 3-6 months). The average median time was 9.5 weeks (range 8-13 weeks). There was no numbness of the advancement flap. Additionally, there was no specific complication at both the recipient and donor sites. Thigh quadriceps muscle strength and activities of the knee were normal. All patients were satisfied with the aesthetic outcome postoperatively at the 3-month to 6-month follow-up.The modified advancement flap pedicled with an AMT perforator is an ideal option for repairing the anterolateral donor site.
The clinical application of anterolateral thigh flap.
Lee, Yao-Chou; Chiu, Haw-Yen; Shieh, Shyh-Jou
2011-01-01
The anterolateral thigh flap can provide a large skin paddle nourished by a long and large-caliber pedicle and can be harvested by two-team work. Most importantly, the donor-site morbidity is minimal. However, the anatomic variations decreased its popularity. By adapting free-style flap concepts, such as preoperative mapping of the perforators and being familiar with retrograde perforator dissection, this disadvantage had been overcome gradually. Furthermore, several modifications widen its clinical applications: the fascia lata can be included for sling or tendon reconstruction, the bulkiness could be created by including vastus lateralis muscle or deepithelization of skin flap, the pliability could be increased by suprafascial dissection or primary thinning, the pedicle length could be lengthening by proximally eccentric placement of the perforator, and so forth. Combined with these technical and conceptual advancements, the anterolateral thigh flap has become the workhorse flap for soft-tissue reconstructions from head to toe.
The Clinical Application of Anterolateral Thigh Flap
Lee, Yao-Chou; Chiu, Haw-Yen; Shieh, Shyh-Jou
2011-01-01
The anterolateral thigh flap can provide a large skin paddle nourished by a long and large-caliber pedicle and can be harvested by two-team work. Most importantly, the donor-site morbidity is minimal. However, the anatomic variations decreased its popularity. By adapting free-style flap concepts, such as preoperative mapping of the perforators and being familiar with retrograde perforator dissection, this disadvantage had been overcome gradually. Furthermore, several modifications widen its clinical applications: the fascia lata can be included for sling or tendon reconstruction, the bulkiness could be created by including vastus lateralis muscle or deepithelization of skin flap, the pliability could be increased by suprafascial dissection or primary thinning, the pedicle length could be lengthening by proximally eccentric placement of the perforator, and so forth. Combined with these technical and conceptual advancements, the anterolateral thigh flap has become the workhorse flap for soft-tissue reconstructions from head to toe. PMID:22567234
Kim, Chae Min; Yun, In Sik; Lee, Dong Won; Lew, Dae Hyun; Rah, Dong Kyun; Lee, Won Jai
2014-07-01
Reconstruction of ischial pressure sore defects is challenging due to extensive bursas and high recurrence rates. In this study, we simultaneously applied a muscle flap that covered the exposed ischium and large bursa with sufficient muscular volume and a profunda femoris artery perforator fasciocutaneous flap for the management of ischial pressure sores. We retrospectively analyzed data from 14 patients (16 ischial sores) whose ischial defects had been reconstructed using both a profunda femoris artery perforator flap and a muscle flap between January 2006 and February 2014. We compared patient characteristics, operative procedure, and clinical course. All flaps survived the entire follow-up period. Seven patients (50%) had a history of surgery at the site of the ischial pressure sore. The mean age of the patients included was 52.8 years (range, 18-85 years). The mean follow-up period was 27.9 months (range, 3-57 months). In two patients, a biceps femoris muscle flap was used, while a gracilis muscle flap was used in the remaining patients. In four cases (25%), wound dehiscence occurred, but healed without further complication after resuturing. Additionally, congestion occurred in one case (6%), but resolved with conservative treatment. Among 16 cases, there was only one (6%) recurrence at 34 months. The combination of a profunda femoris artery perforator fasciocutaneous flap and muscle flap for the treatment of ischial pressure sores provided pliability, adequate bulkiness and few long-term complications. Therefore, this may be used as an alternative treatment method for ischial pressure sores.
Kim, Chae Min; Yun, In Sik; Lee, Dong Won; Lew, Dae Hyun; Rah, Dong Kyun
2014-01-01
Background Reconstruction of ischial pressure sore defects is challenging due to extensive bursas and high recurrence rates. In this study, we simultaneously applied a muscle flap that covered the exposed ischium and large bursa with sufficient muscular volume and a profunda femoris artery perforator fasciocutaneous flap for the management of ischial pressure sores. Methods We retrospectively analyzed data from 14 patients (16 ischial sores) whose ischial defects had been reconstructed using both a profunda femoris artery perforator flap and a muscle flap between January 2006 and February 2014. We compared patient characteristics, operative procedure, and clinical course. Results All flaps survived the entire follow-up period. Seven patients (50%) had a history of surgery at the site of the ischial pressure sore. The mean age of the patients included was 52.8 years (range, 18-85 years). The mean follow-up period was 27.9 months (range, 3-57 months). In two patients, a biceps femoris muscle flap was used, while a gracilis muscle flap was used in the remaining patients. In four cases (25%), wound dehiscence occurred, but healed without further complication after resuturing. Additionally, congestion occurred in one case (6%), but resolved with conservative treatment. Among 16 cases, there was only one (6%) recurrence at 34 months. Conclusions The combination of a profunda femoris artery perforator fasciocutaneous flap and muscle flap for the treatment of ischial pressure sores provided pliability, adequate bulkiness and few long-term complications. Therefore, this may be used as an alternative treatment method for ischial pressure sores. PMID:25075362
Smith, Lane F; Smith, Lane F
2015-05-01
There continues to be controversy about performing abdominoplasty concurrently with abdominal liposuction. The concern is that liposuction on the already vascularly compromised abdominal flap will lead to increased complications and flap necrosis. The central abdomen is supplied by the epigastric system. If perforator vessels from this system are spared, the blood supply to the abdomen can be spared and liposuction should be able to be safely performed on the elevated abdominal flap. The purpose of this study was to evaluate the safety of abdominoplasty with concurrent abdominal liposuction when a perforator vessel is spared. A standard abdominoplasty was performed, sparing one or two perforator vessels from the deep superior epigastric artery system. A retrospective chart review of 300 consecutive patients who underwent abdominoplasty surgery combined with concurrent abdominal liposuction was performed. Complications, total volume of abdominal liposuction, and results were reviewed. The overall complication rate was 17.3 percent (52 patients). Sixteen percent (48 patients) suffered minor complications and 1.3 percent (four patients) suffered major complications. Abdominoplasty can be combined safely with concurrent abdominal liposuction when a perforator vessel is spared. The combination of concurrent liposuction with abdominoplasty showed no increase in complication rates when a perforator vessel was spared. The perforator vessels are located consistently in a 2-cm radius located 4 cm from the midline and 6 cm from the subcostal margin. The potential advantages of abdominoplasty with concurrent liposuction include a better postoperative cosmetic result. Therapeutic, IV.
MRA of the skin: mapping for advanced breast reconstructive surgery.
Thimmappa, N D; Vasile, J V; Ahn, C Y; Levine, J L; Prince, M R
2018-02-27
Autologous breast reconstruction using muscle-sparing free flaps are becoming increasingly popular, although microvascular free flap reconstruction has been utilised for autologous breast reconstructions for >20 years. This innovative microsurgical technique involves meticulous dissection of artery-vein bundle (perforators) responsible for perfusion of the subcutaneous fat and skin of the flap; however, due to unpredictable anatomical variations, preoperative imaging of the donor site to select appropriate perforators has become routine. Preoperative imaging also reduces operating time and enhances the surgeon's confidence in choosing the appropriate donor site for harvesting flaps. Although computed tomography angiography has been widely used for preoperative imaging, concerns over excessive exposure to ionising radiation and poor iodinated contrast agent enhancement of the intramuscular perforator course has made magnetic resonance angiography, the first choice imaging modality in our centre. Magnetic resonance angiography with specific post-processing of the images has established itself as a reliable method for mapping tiny perforator vessels. Multiple donor sites can be imaged in a single setting without concern for ionising radiation exposure. This provides anatomical information of more reconstruction donor site options, so that a surgeon can design a flap of tissue centralised around the best perforator, as well as a back-up perforator, and even a back-up flap option located on a different region of the body. This information is especially helpful in patients with a history of scar tissue from previous surgeries, where the primary choice perforator is found to be damaged or unsuitable intraoperatively. In addition, chest magnetic resonance angiography evaluates recipient site blood vessel suitability including vessel diameters, course, and branching patterns. In this article we provide a broad overview of various skin flaps, clinical indications, advantages and disadvantages of each of these flaps, basic imaging technique, along with advanced sequences for visualising tiny arteries in the groin and in the chest. Post-processing techniques, structure of the report and how automation of the reporting system improves workflow is described. We also describe applications of magnetic resonance angiography in postoperative imaging. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Tran, Bao Ngoc N; Fadayomi, Ayotunde; Lin, Samuel J; Singhal, Dhruv; Lee, Bernard T
2017-09-01
Two staged tissue expander-implant with acellular dermal matrix (TE/I + ADM) and deep inferior epigastric perforator (DIEP) flap are the most common implant and autologous methods of reconstruction in the U.S. Implant-based techniques are disproportionally more popular, partially due to its presumed cost effectiveness. We performed a comprehensive cost analysis to compare TE/I + ADM and DIEP flap. A comparative cost analysis of TE/I + ADM and DIEP flap was performed. Medicare reimbursement costs for each procedure and their associated complications were calculated. Pooled probabilities of complications including cellulitis, seroma, skin necrosis, implant removal, flap loss, partial flap loss, and fat necrosis, were calculated using published studies from 2010 to 2016. Average actual cost for successful TE/I + ADM and DIEP flap were $13 304.55 and $10 237.13, respectively. Incorporating pooled complication data from published literature resulted in an increase in cost to $13 963.46 for TE/I + ADM and $12 624.29 for DIEP flap. The expected costs for successful TE/I + ADM and DIEP flap were $9700.35 and $8644.23, which are lower than the actual costs. DIEP flap breast reconstruction incurs lower costs compared to TE/I + ADM. These costs are lower at baseline and when additional costs from pooled complications are incorporated. © 2017 Wiley Periodicals, Inc.
Dast, Sandy; Havet, Eric; Dessena, Lidia; Abdulshakoor, Abeer; Alharbi, Mohammed; Vaucher, Richard; Herlin, Christian; Sinna, Raphael
2017-08-01
The concept of extended thoracodorsal artery perforator (TDAP) flap was described in 2015 for breast reconstruction. Our anatomical study aims to identify the territories vascularised by the thoracodorsal artery perforator via the deep muscular fascial network. The second goal was to define the volume of the extended TDAP flap. Ten extended TDAP flaps were dissected on 5 fresh human cadavers. Around the classical skin paddle of a TDAP flap, the dissections were performed in a subfascial level, including the muscular fascia and the adipose tissue compartments to increase the volume of the flap. After injection of methylene blue in the thoracodorsal artery, we measured the length and width, the surface and the volume of the coloured flap. The mean sizes of the extended TDAP flap were 24.9 cm × 20.1 cm. The mean surface of the total vascularization zone was 441 cm 2 . The mean volume of the vascularized flap was 193 ml. The thoracodorsal artery perforator via the deep muscular fascial network allows us to harvest a flap of 25 cm × 20 cm with a mean surface of 441 cm² and a mean volume of 193 ml. The extended TDAP flap is a credible option in breast reconstruction.
Hunsinger, Vincent; Lhuaire, Martin; Haddad, Kevin; Wirz, Francesco-Saverio; Abedalthaqafi, Samah; Obadia, Déborah; Derder, Mohamed; Marchac, Alexandre; Benjoar, Marc David; Hivelin, Mikael; Lantieri, Laurent
2018-06-02
The volume of the profunda femoris artery perforator (PAP) flap limits its indications to small- and medium-sized breast reconstructions after modified radical mastectomy for cancer. We report a modified PAP flap design, including not only a vertical extension that increases its volume but also the skin surface, which suits larger breasts requiring immediate or delayed breast reconstructions and compare the results with our horizontal skin paddle PAP flap experience. In our center between November 2014 and November 2016, 51 consecutive patients underwent a PAP flap breast reconstruction following breast cancer. A retrospective analysis on the collected data was performed to compare 34 patients with a bra cup smaller than C who underwent 41 horizontal PAP flap procedures, with those ( n = 17) of a bra cup greater than or equal to C who underwent 21 fleur-de-lys PAP flap procedures. Demographic, anthropometric, flap and surgical characteristics, postoperative complication rates, and hospital stay were compared between the two groups. The average flap weight was 480 g (range: 340-735 g) for the fleur-de-lys PAP flap group compared with 222 g (range: 187-325 g) for the horizontal PAP flap procedure ( p < 0.001). The mean flap dimensions were 25 × 18 cm for the fleur-de-lys PAP flap group compared with 25 × 7 cm in the horizontal PAP flap group. No flap failure was observed in the fleur-de-lys PAP flap group compared with two flap failures secondary to venous thrombosis in the horizontal PAP flap group ( NS ). Three patients (14%) experienced delayed healing at the donor site compared with four patients (10%) in the horizontal PAP flap group ( NS ). The fleur-de-lys skin paddle design not only allows an increase of the horizontal PAP flap volume, but also increases the skin surface, with an acceptable donor site morbidity. For medium- or large-sized breasts, the fleur-de-lys PAP flap seems to be ideal when a DIEP flap-based reconstruction is contraindicated. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Zhu, Shan; Liu, Yuanbo; Yu, Shengji; Zang, Mengqing; Zhao, Zhenguo; Xu, Libin; Zhang, Xinxin; Chen, Bo; Ding, Qiang
2016-01-01
To explore the feasibility and technical essentials of soft tissue defect reconstruction following malignant tumor removal of limbs using perforator propeller flaps. Between July 2008 and July 2015, 19 patients with malignant limb tumor underwent defect reconstruction following tumor removal using the perforator propeller flaps. There were 13 males and 6 females with an average age of 53.4 years (range, 20-82 years). The disease duration ranged from 1 to 420 months (mean, 82 months). The tumors located at the thigh in 10 cases, at the leg in 2 cases, at the arm in 1 case, at the forearm in 1 case, around the knee in 2 cases, and around the elbow joint in 3 cases. Totally 23 flaps (from 8 cm x 3 cm to 30 cm x 13 cm in size) were used to reconstruct defects (from 4 cm x 4 cm to 24 cm x 16 cm in size). The potential source arteries included the femoral artery (n = 2), profunda femoral artery (n = 3), superficial circumflex iliac artery (n = 1), lateral circumflex femoral artery (n = 6), superior lateral genicular artery (n = 2), peroneal artery (n = 2), anterior tibial artery (n = 1), brachial artery (n = 4), and radial artery (n = 1). The remaining one was a free style perforator flap. Partial distal flap necrosis occurred in 3 cases after surgery with rotation angles of 180, 150, and 100 degrees respectively, which were reconstructed after debridement using a free-style perforator flap in 1 case and using free skin grafting in the other 2 cases. The other 20 flaps survived completely after surgery. Primary healing of incisions was obtained at the donor and recipient sites. There was no severe complication such as infection, hematoma, and total flap failure. All patients were followed up 3 months to 5 years (mean, 19 months). One patient with malignant melanoma around the elbow joint had tumor recurrence, and underwent secondary tumor resection. The appearance, texture, and color of the flaps were similar to those at the recipient site. For patients with malignant tumor of the limb, the perforator propeller flap can be an alternative option for soft tissue defect reconstruction after tumor resection, with the advantages of relatively simple operation and remaining the main vessels.
Schaverien, Mark V; Ludman, Catherine N; Neil-Dwyer, Jason; McCulley, Stephen J
2011-12-01
The anatomy of the anterior abdominal wall is highly variable and leads to uncertainty when harvesting a deep inferior epigastric artery perforator flap. Presurgical imaging has been shown to reduce the operating time, as well as reduce the rates of flap and donor site complications. The importance of imaging of the venous system has also been recognized for reducing the risk of venous congestion. The modalities currently available for presurgical imaging include handheld Doppler ultrasound, duplex ultrasound, computed tomographic angiography (CTA), and contrast-enhanced magnetic resonance angiography (CE-MRA). Of these, the most promising are CTA and CE-MRA, and advantages and disadvantages exist for both modalities. In this article, we review the use of CE-MRA for preoperative flap imaging and report our experience with its use in deep inferior epigastric artery perforator flap harvest, as well as compare it with CTA. We also explore the future directions for presurgical flap imaging.
Innocenti, M; Cardin-Langlois, E; Menichini, G; Baldrighi, C
2014-02-01
Soft tissue defects involving the anterior aspect of the knee are a frequent finding in a number of pathological conditions. The aim of this article is to describe a new pedicled flap consisting of a conventional medial gastrocnaemius muscle flap associated with a propeller flap based on a perforator of the medial sural artery. Five males ranging in age between 26 and 72 years underwent a reconstruction of the soft tissue of the knee by means of the described procedure. Three patients sustained complex tissue loss subsequent to high-energy trauma; two losses were due to septic complications after elective knee surgery. Four flaps survived allowing adequate proximal tibial metaphysis and patella coverage. One patient underwent early above-the-knee amputation due to life-threatening septicaemia. The described chimaera flap consists of a medial gastrocnaemius flap with a skin paddle that is elevated on a perforator of the medial sural artery and then rotated according to the propeller flaps' principles. It provides effective coverage of large soft tissue defects of the knee. In the authors' experience, the propeller flap portion proved to be particularly useful to cover the patella, while the muscle flap was used to cover the proximal metaphysis of the tibia and fill the dead space if present. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Legemate, Catherine M; van der Kwaak, Monique; Gobets, David; Huikeshoven, Menno; van Zuijlen, Paul P M
2018-06-01
The ischial region is the site most affected by pressure sores and has the highest recurrence and complication rates compared to other affected sites. We developed a practical and safe pedicled flap for reconstruction of ischial pressure sores based on the rich available perforators from the internal pudendal artery and the surplus of skin at the infragluteal fold. A retrospective cohort study was conducted in all patients who underwent ischial pressure ulcer reconstruction using the PIPAP flap between March 2010 and March 2017. The skin flap was designed along the gluteal fold. The skin perforators of the pudendal artery were marked with a Doppler probe in the medial region of the gluteal fold. Surgery was performed in the jackknife position, and flaps were elevated in the suprafascial plane. Patients were assessed for minor (requiring no additional surgery) and major complications (requiring additional surgery). Twenty-seven patients (34 flaps) were identified. The median follow-up period was 38 months (IQR 37). Primary closure of the donor-site was achieved in all procedures, only one flap required muscle flap transposition in order to fill the dead space. The mean operating time was 60 ± 21 minutes. In six flaps (9%) wound healing problems were noted that did not require an additional operative procedure. Among the nine flaps (27%) that required a second procedure, 3 (9%) were necessary due to recurrent ulcers. The PIPAP flap is a safe and reliable alternative for ischial pressure sore reconstruction, certainly when compared to available techniques. Moreover, it has significant advantages over other techniques including minimal donor-site morbidity, preservation of posterior thigh skin, buttock-line integrity and reliable vascularity. Copyright © 2018 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Umbilical necrosis rates after abdominal-based microsurgical breast reconstruction.
Ricci, Joseph A; Kamali, Parisa; Becherer, Babette E; Curiel, Daniel; Wu, Winona; Tobias, Adam M; Lin, Samuel J; Lee, Bernard T
2017-07-01
Umbilical stalk necrosis represents a rare, yet important complication after abdominal-based microsurgical breast reconstruction, which is both underrecognized and understudied in the literature. Once identified, umbilical reconstruction can be an extremely challenging problem. All consecutive breast free flaps at a single institution from February 2004 to February 2016 were reviewed, excluding non-abdominal-based flaps. Patients were divided based on the development of umbilical necrosis postoperatively. Demographics, surgical characteristics, and other complications were compared between the groups. A total of 918 patients met the inclusion criteria, with 29 developing umbilical necrosis identified (3.2%). Patients developing necrosis tended to be older (49.4 yrs versus 52.9 yrs; P < 0.01); have higher BMI (31.3 versus 27.8; P < 0.01); and were more likely to be smokers (27.5% versus 11.6%; P = 0.01). Umbilical necrosis was also associated with increased flap weight (830 g versus 656 g; P < 0.01), decreased time of perforator dissection (151 min versus 169 min; P = 0.02); bilateral cases (68.9% versus 44.7%; P < 0.01), and increased number of perforators per flap (2.5 versus 2.2; P = 0.03). There was no association with flap type (deep inferior epigastric perforator, superficial inferior epigastric artery, or free TRAM), diabetes, previous abdominal surgery, or use of preoperative imaging. Umbilical necrosis was not associated with any concomitant complications. Umbilical stalk necrosis was found to occur in 3.2% of patients and was associated with several preoperative comorbidities and intraoperative characteristics. This information should help influence intraoperative decision-making to prevent the development of this undesirable complication. Copyright © 2017 Elsevier Inc. All rights reserved.
Long-term follow-up for keystone design perforator island flap for closure of myelomeningocele.
Donaldson, Christopher; Murday, Hamsaveni K M; Gutman, Matthew J; Maher, Rory; Goldschlager, Tony; Xenos, Chris; Danks, R Andrew
2018-04-01
We have previously reported a small series on the closure of large myelomeningocele (MMC) defects with a keystone design perforator island flap (KDPIF) in a paediatric neurosurgical centre in Australia. We are now presenting an updated longer term follow-up of an expanded series demonstrating longer term durability of this vascularized flap for large myelomeningocele defects. The prospective data from the Monash Neurosurgical Database were used to select all cases of MMC between December 2008 and September 2016. Retrospective analysis of the neurosurgical database revealed an additional three patients who underwent KDPIF closure at the Monash Medical Centre for MMC repair at birth. Wound healing was satisfactory in all six cases. With delayed follow-up, there was no associated skin flap separation, skin flap dehiscence, skin flap necrosis, cerebro-spinal fluid leak, however two infections were encountered, both resolved with conservative management including antibiotics and simple washout. In this expanded case series with increased longevity of follow-up, the keystone design perforator island flap remains a robust alternative for closure of large myelomeningocele defects.
Free-flap surgical correction of facial deformity after anteromedial maxillectomy.
Sarukawa, Shunji; Kamochi, Hideaki; Noguchi, Tadahide; Sunaga, Ataru; Uda, Hirokazu; Mori, Yoshiyuki; Nishino, Hiroshi; Yoshimura, Kotaro
2017-09-01
Anteromedial maxillectomy is typically performed in conjunction with low-dose radiotherapy and intraarterial chemotherapy. In doing so, the extent of surgical defects is reduced. However, nasal deviation and oral incompetence may ensue, due to cicatricial contracture of wounds, and may be distressing to these patients. Herein, we report a series of eight free perforator flap procedures (anterolateral thigh [ALT] flap, 6; thoracodorsal artery perforator [TAP] flap, 2) used to correct such deformities. The TAP flap was combined with scapular tip [ST] osseous flap in patients with added zygomatic prominence defects. Three adipocutaneous parts developed from each perforator flap were applied as follows: two to reconstruct nasal lining and oral vestibule, and one to augment cheek volume. All aesthetic results proved satisfactory, although orbital dystopia and contracture of mimic muscles were not resolved completely. These secondary interventions are suitable for sequelae of simple anteromedial maxillectomy. Immediate reconstruction should be considered if orbital floor and mimic muscles are involved. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Endoscopic closure of septal perforations.
Alobid, Isam
The management of septal perforations is a challenge for the surgeon. A wide variety of surgical techniques have been described, with different approaches. There is no scientific evidence to support a particular approach. The objective of this review is to present a practical guide on the technique of choice for each case of septal perforation. Inspection of the nasal mucosa, the size of the perforation, the location and especially the osteo-cartilaginous support, are the pillars of a successful surgery. For the sliding or rotating flaps of the mucosa of the septum it is essential to know in advance if the elevation of the mucopericondrio or mucoperiosteo of the septum is possible, otherwise the use of these flaps would not be indicated. The flaps of the lateral wall or nasal floor are the alternative. The pericranial flap may be indicated in total or near total perforations. The remnant of the nasal septum and status of osteo-cartilaginous support are the determining factors in the management of septal perforations. Each case should be evaluated individually and the approach chosen according to the size and location of the perforation, mucosal quality, personal history, previous surgery and the experience of the surgeon. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.
Versatility of the Angularis Oris Axial Pattern Flap for Facial Reconstruction.
Losinski, Sara L; Stanley, Bryden J; Schallberger, Sandra P; Nelson, Laura L; Towle Millard, Heather A M
2015-11-01
To describe the versatility of the axial pattern flap based on the cutaneous perforating branch of the angularis oris artery for reconstruction of large facial defects in dogs, including complications and clinical outcomes. Retrospective clinical case series. Client-owned dogs (n = 8). Facial flaps (n = 9) based at the commissure of the lip with a caudodorsal orientation were utilized, with established anatomical borders. Flaps were elevated deep to the panniculus carnosus in a caudal to rostral direction, preserving the angularis oris artery, its cutaneous perforator, and surrounding cutaneous vasculature. Flaps were rotated dorsally or ventrally to cover the defect. Primary closure of the donor site was by direct apposition in all cases. Angularis oris axial pattern flaps were most commonly used to close large defects of the nasomaxillary area rostral to the eyes (6 dogs), followed by orbital (2) and intermandibular (1) defects. Defects occurred because of tumor resection (6 dogs), trauma (2), and a chronic, non-healing wounding (1). All flaps healed with acceptable functional and cosmetic outcomes without major complications. Followup ranged from 10 days to 16 months. Minor postoperative complications included flap edema (8 dogs), partial incisional dehiscence (3), distal tip necrosis (2), and oroantral fistula recurrence (1). Angularis oris axial pattern flaps provided hirsute, full-thickness skin coverage of a variety of large facial defects with minor complications, and should be considered when restructuring large defects of the rostral face or chin. © Copyright 2015 by The American College of Veterinary Surgeons.
Smith, Lane F.
2015-01-01
Background: There continues to be controversy about performing abdominoplasty concurrently with abdominal liposuction. The concern is that liposuction on the already vascularly compromised abdominal flap will lead to increased complications and flap necrosis. The central abdomen is supplied by the epigastric system. If perforator vessels from this system are spared, the blood supply to the abdomen can be spared and liposuction should be able to be safely performed on the elevated abdominal flap. The purpose of this study was to evaluate the safety of abdominoplasty with concurrent abdominal liposuction when a perforator vessel is spared. Methods: A standard abdominoplasty was performed, sparing one or two perforator vessels from the deep superior epigastric artery system. A retrospective chart review of 300 consecutive patients who underwent abdominoplasty surgery combined with concurrent abdominal liposuction was performed. Complications, total volume of abdominal liposuction, and results were reviewed. Results: The overall complication rate was 17.3 percent (52 patients). Sixteen percent (48 patients) suffered minor complications and 1.3 percent (four patients) suffered major complications. Conclusions: Abdominoplasty can be combined safely with concurrent abdominal liposuction when a perforator vessel is spared. The combination of concurrent liposuction with abdominoplasty showed no increase in complication rates when a perforator vessel was spared. The perforator vessels are located consistently in a 2-cm radius located 4 cm from the midline and 6 cm from the subcostal margin. The potential advantages of abdominoplasty with concurrent liposuction include a better postoperative cosmetic result. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV. PMID:25919250
La Padula, Simone; Hersant, Barbara; Meningaud, Jean Paul
2018-03-30
Anatomical variability of anterolateral thigh flap (ALT) perforators has been reported. The aim of this study is to assess if the use of intraoperative indocyanine green angiography (iICGA) can help surgeons to choose the ALT flap best perforator to be preserved. A retrospective study was conducted in 28 patients with open tibial fracture, following a road traffic crash, who had undergone ALT flap. Patients were classified into two groups: ICGA group (iICGA was used to select the more reliable perforator) and control group. The mean tissue loss size of the ICGA group (n = 13, 11 men and 2 women, mean age: 52 ± 6 years) was of 16.6 cm × 12.2 cm. The mean defect size of the control group (n = 15, 14 men and 1 women, mean age: 50 ± 5.52 years) was of 15.3 cm × 11.1 cm. Statistical analysis was performed to analyze and compare the results. ICGA allowed preserving only the most functional perforator, that provided the best ALT flap perfusion in 10 out of the 13 cases (77%). ICGA allowed a significant operative time reduction (160 ± 23 vs. 202 ± 48 minutes; P < .001). One case of distal necrosis was observed in the ICGA group (mean follow-up 12.3 months), while partial skin necrosis occurred in three cases of the control group (mean follow-up 13.1 months); P = .35. No additional coverage was required and a successful bone healing was observed in both groups. These findings suggest that iICGA is an effective method that allows to select the most reliable ALT flap perforators and to reduce operative time. © 2018 Wiley Periodicals, Inc.
Case Report Reconstruction of Exposed Ilium With Reverse Turnover Latissimus Dorsi Muscle Flap
Hayashida, Kenji; Endo, Yoshie; Kamebuchi, Katsuhiko
2011-01-01
Objective: It is difficult to cover a large skin and soft tissue defect with exposure of the ilium. We therefore performed a new reconstruction technique, using a reverse latissimus dorsi muscle flap fed by perforating branches of only the 10th intercostal artery. Methods: A 45-year-old man had a large traumatic defect located on the hip with exposure of the iliac crest. After confirming and preserving perforating branches of the 10th intercostal artery, the latissimus dorsi muscle flap was turned over just proximal to the perforating branch, and a split-thickness skin graft was performed over the flap. Results: The skin graft took place well and there were no circulation problems. Conclusions: This flap covered a larger area on the hip than the musculocutaneous flap. Furthermore, this is easier to perform and is less invasive than a vascularized free flap. Skin and soft tissue defects that expose bones of the lumbar or hip region can be reconstructed with a local flap; however, the deficit is small for this coverage and usually there is little skin and soft tissue to cover the wound defect in the surrounding area. Thus, it is often difficult to deal with large defects. We performed a reconstruction, using a reverse latissimus dorsi flap fed by perforating branches of the 10th intercostal artery for a large skin and soft tissue defect of the hip with exposure of the iliac crest, resulting in a good outcome. This technique is thought to be useful for reconstruction when the ilium is exposed, and we report the case and surgical procedure. PMID:21559059
Demirtas, Yener; Ayhan, Suhan; Findikcioglu, Kemal; Yavuzer, Reha; Atabay, Kenan
2007-05-01
Research in prevention of partial flap necrosis has recently concentrated on extending the safe length of a flap by ligating vessels of known territories. To advance this approach one step further, the authors decided to reveal the least invasive surgical strategy for transfer of angiosomes. The study was arranged into three experiments. In the first experiment (n = 17 rabbits), a cutaneous island flap model spanning four adjacent vascular territories was developed. In the second experiment (n = 15 rabbits), the flap model was used to test the possibility of desiccating those vessels supplying the angiosomes to be captured percutaneously with radiofrequency. The delay procedures were performed by means of minimal skin incisions, and the flaps were elevated after a 2-week delay period. In the third experiment, the effectiveness of selective interference of these pedicles was compared to minimize the number of target vessels for successful transfer of angiosomes. The mean surviving area of the new flap model was 63 +/- 2 percent. The mean surviving flap area was 97 +/- 3 percent for the endoscopy equivalent technique and 94 +/- 4 percent for radiofrequency delay. The results were statistically insignificant between these two groups. In experiment 3, comparison of the results yielded a statistically insignificant difference for flap survival area among all four of the groups. An alternative flap model is introduced for future investigation of the vascular delay process. Percutaneous desiccation of the perforators with radiofrequency was found to be a reliable method, and selective desiccation of the perforator(s) was as efficient as destruction of all vascular sources other than the pedicle.
Fernandes, Rui; Lee, Jason
2007-10-01
The reconstruction of large avulsive tissue loss in the head and neck region is one of the most difficult tasks faced by reconstructive surgeons. The advent of free tissue transfer has improved our ability to predictably reconstruct these patients. One of the most recent advances in the field of microvascular surgery is the use of perforator flaps. We have used the lateral circumflex femoral artery perforator (LCFAP) flap for reconstructions in patients who have suffered severe gunshot wounds (GSWs) to the maxillofacial area. A retrospective chart review was conducted of patients treated with a LCFAP flap in our division for large defects of the face resulting from GSWs between July 2005 and July 2006. The patient's age and gender, site and size of defect, and degree of bone and soft tissue loss were recorded. Flap survival and donor site morbidity were noted as outcomes of the reconstruction. Four patients who met the inclusion criteria were identified. The success rate for the flaps was 100%. There was no partial necrosis of the flaps. The size of the defect ranged from 20 x 10 cm to 10 x 10 cm. None of the patients had donor site complications, and all donor sites were closed primarily. Use of the LCFAP flap for the reconstruction of large defects secondary to GSWs to the face is a reliable option for the immediate reconstruction of this patient population. The lateral circumflex femoral artery perforator (LCFAP) flap is at a site not involved in the immediate resuscitation of trauma patients, thus ensuring an intact vascular system. This fact makes the LCFAP flap a reliable source for small to large soft tissues for reconstructing avulsive soft tissue losses in the head and neck.
Gunnarsson, Gudjon L.; Børsen-Koch, Mikkel; Nielsen, Henrik T.; Salzberg, Andrew
2015-01-01
Summary: We present our experience of bilateral total breast reconstruction using a double-sided extended thoracodorsal artery perforator propeller flap in a case series of 10 patients. Reconstruction was successfully achieved in all cases with few complications. The median time for surgery was 275 minutes (200–330), and the average implant size used was 350 cm3 (195–650). We demonstrate how the extended thoracodorsal artery perforator propeller flap allows for a swift and reliable direct to implant bilateral total breast reconstruction in a simple setting and is a valuable adjunct to our armamentarium of techniques for single-stage bilateral breast reconstruction. PMID:26180736
Chen, Yen-Chou; Huang, Eng-Yen; Lin, Pao-Yuan
2014-03-01
The gluteus maximus myocutaneous flap was considered the workhorse that reconstructed sacral pressure sores, but was gradually replaced by fasciocutaneous flap because of several disadvantages. With the advent of the perforator flap technique, gluteal perforator (GP) flap has gained popularity nowadays. The aim of this study was to compare the complications and outcomes between GP flaps and gluteal fasciocutaneous rotation (FR) flaps in the treatment of sacral pressure sores. Between April 2007 and June 2012, 63 patients underwent sacral pressure sore reconstructions, with a GP flap used in 31 cases and an FR flap used in 32 cases. Data collected on the patients included patient age, gender, co-morbidity for being bedridden and follow-up time. Surgical details collected included the defect size, operative time and estimated blood loss. Complications recorded included re-operation, dehiscence, flap necrosis, wound infection, sinus formation, donor-site morbidity and recurrence. The complications and clinical outcomes were compared between these two groups. We found that there was no significant difference in patient demographics, surgical complications and recurrence between these two groups. In gluteal FR flap group, all recurrent cases (five) were treated by reuse of previous flaps. Both methods are comparable, good and safe in treating sacral pressure sores. Gluteal FR flap can be performed without microsurgical dissection, and re-rotation is feasible in recurrent cases. The authors suggest using gluteal FR flaps in patients with a high risk of sore recurrence. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Abdelrahman, Islam; Moghazy, Amr; Abbas, Ashraf; Elmasry, Moustafa; Adly, Osama; Elbadawy, Mohamed; Steinvall, Ingrid; Sjoberg, Folke
2016-08-01
Distal half leg complex wounds are usually a formidable problem that necessitates either local or free flap coverage. The aim of this study was to compare cost billing charges in free Gracilis flap (fGF) and local fasciocutaneous perforator flap (lFPF) in reconstructing complex soft tissue leg and foot defects. Thirty consecutive adult (>15-year-old) patients with soft tissue defects in the leg and/or foot requiring tissue coverage with a flap in the period between 2012 and 2015 were randomly assigned (block randomization) to either an fGF or lFPF procedure. The outcome measures addressed were total billed charges costs, perioperative billed charges cost, partial or complete flap loss, length of hospital stay, inpatient postsurgical care duration, complications, operating time and number of operative scrub staff. One patient suffered from complete flap loss in each group. Reconstruction with lFPF showed total lower billed charges costs by 62% (2509 USD) (p < 0.001) and perioperative billed charges cost by 54% (779 USD) (p < 0.001), and shorter total hospital stay (36.5 days; p < 0.001), inpatient postsurgical care duration (6.4 days; p < 0.001), operating time (4.3 h; p < 0.001) and fewer scrub staff (2.2 persons; p < 0.001). These results suggest that neither flap is totally superior to the other; the choice should instead be based on the outcome sought and logistics. lFPF requires lower billed charges cost and resource use and saves operative time and personnel and reduces length of hospital stay. Our approach changed towards using perforator flaps in medium-sized defects, keeping the free flap option for larger defects. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
[Locoregional solutions for groin defects : Coverage after vascular surgery].
Cerny, M; Harder, Y; Zimmermann, A; Eckstein, H-H; Machens, H-G; Schantz, J-T; Schenck, T L
2017-01-01
Vascular surgery through a groin incision may be associated with severe wound healing disorders in this sensitive area. There are many options to reconstruct the defect surgically. The choice of surgical reconstruction depends mainly on the individual status of vasculature, which is most often compromised in these patients. There are random pattern flaps, as well as perforator, pedicled flaps or microvascular flaps to choose from. We give an overview of plastic surgical solutions for groin defects, with a special focus on complex wounds after vascular surgical complications. We discuss advantages and disadvantages of different flaps with two case reports and also show alternatives. We demonstrate in two cases how the reconstruction of the groin defect was planned, taking into account the vascular status, and why we chose an innovative and seldom-used option in each case. The selected flaps, a pedicled fasciocutaneous ALT propeller flap and a perforator-based, pedicled abdominal advancement flap reconstructed the defects successfully. The surgical therapy for the reconstruction of groin defects should be chosen according to the individual vascular status to ensure safe and reliable blood supply. To guarantee the best possible reconstruction and avoid postoperative healing disorders and infections, less common flaps should also be considered.
Ismail, H.; Elshobaky, A.
2016-01-01
Summary Anterior cervical contractures of the neck represent a great challenge for plastic and reconstructive surgeons. Necks can be reconstructed with a wide range of surgical techniques, including chimeric flaps, supercharged flap, pre-expanded flaps, “superthin” flaps and perforator flaps. The supraclavicular flap is easy to harvest without the need for free tissue transfer. It provides a relatively large flap for neck resurfacing with tissue very similar to that of the neck. Between January 2013 and March 2015, 20 patients suffering from postburn neck contracture underwent reconstruction with 20 unilateral supraclavicular artery perforator flaps. Nineteen patients had post-burn neck contractures (9 cases type Іc, 10 cases type Пc) while only one had post-burn granulation tissue in the neck. We harvested fifteen flaps from the right side and five from the left. Size of the reconstructed defect ranged from 23x10 to14x6, and flap size varied from 25/11 to 16/7cm. Period of follow up ranged from 27-2months (average 12.3). Nineteen flaps survived well (95% survival rate): only one was lost due to iatrogenic extensive dissection over the pedicle. Five cases showed distal superficial epidermolysis, and 2 cases showed 2 cm complete distal necrosis. All patients were managed conservatively. Our results coincide with other literature results confirming the efficacy and rich vascularity of this flap. In all cases with distal partial necrosis, flaps were 23 cm or more. We recommend that supraclavicular flaps of more than 22 cm in length are not harvested immediately and that flaps are expanded before harvesting. Expanding the supraclavicular flap increases its surface area and decreases donor site morbidity. PMID:28149252
Ettinger, Kyle S; Alexander, Amy E; Arce, Kevin
2018-04-10
Virtual surgical planning (VSP), computer-aided design and computer-aided modeling, and 3-dimensional printing are 3 distinct technologies that have become increasingly used in head and neck oncology and microvascular reconstruction. Although each of these technologies has long been used for treatment planning in other surgical disciplines, such as craniofacial surgery, trauma surgery, temporomandibular joint surgery, and orthognathic surgery, its widespread use in head and neck reconstructive surgery remains a much more recent event. In response to the growing trend of VSP being used for the planning of fibular free flaps in head and neck reconstruction, some surgeons have questioned the technology's implementation based on its inadequacy in addressing other reconstructive considerations beyond hard tissue anatomy. Detractors of VSP for head and neck reconstruction highlight its lack of capability in accounting for multiple reconstructive factors, such as recipient vessel selection, vascular pedicle reach, need for dead space obliteration, and skin paddle perforator location. It is with this premise in mind that the authors report on a straightforward technique for anatomically localizing peroneal artery perforators during VSP for osteocutaneous fibular free flaps in which bone and a soft tissue skin paddle are required for ablative reconstruction. The technique allows for anatomic perforator localization during the VSP session based solely on data existent at preoperative computed tomographic angiography (CTA); it does not require any modifications to preoperative clinical workflows. It is the authors' presumption that many surgeons in the field are unaware of this planning capability within the context of modern VSP for head and neck reconstruction. The primary purpose of this report is to introduce and further familiarize surgeons with the technique of CTA perforator localization as a method of improving intraoperative fidelity for VSP of osteocutaneous fibular free flaps. Copyright © 2018. Published by Elsevier Inc.
Libondi, Guido; Ramakrishnan, Venkat
2017-01-01
Background The transverse upper gracilis (TUG) flap is the senior authors’ second choice for autologous breast reconstruction when the DIEP flap is not available. It provides durable, pliable tissue with well hidden scars. The main criticism of this flap is the limited volume, donor site complications, short pedicle and vessel mismatch depending on which recipient vessels are used. We described methods of reducing vessel mismatch, complications of venous coupler and refinements to help give a more superior aesthetic outcome. Methods We describe several maneuvers to help reduce vessel mismatch with the use of the internal mammary (IM) perforator vessels with a modification of the Harashina fish-mouth technique or the use of a vessel bifurcation to increase vessel diameter. We also describe the optimum method of perforator preparation and potential methods to prevent palpable venous couplers. The author’s describe their case series of 14 TUG flaps to reconstruct 13 breasts in 12 patients. Results Eight unilateral, 2 partial breast reconstruction, 1 bilateral and 1 bilateral TUG flap for a unilateral reconstruction was carried out. All flaps survived with one partial flap necrosis, one donor site seroma and two cases of palpable/tender venous couplers. The mean reconstructed breast was 320 grams. Conclusions The TUG flap is a reconstructive challenge, but with correct planning a good aesthetic outcome is possible. The IM perforator is our first choice recipient vessel in TUG breast reconstructions. With meticulous preparation and by overcoming vessel mismatch the use of this recipient vessel is a reliable option. PMID:28861378
Medial sural artery perforator flap: a challenging free flap.
Toyserkani, Navid Mohamadpour; Sørensen, Jens Ahm
Oral and extremity defect reconstruction can often require a flap that is thin, and traditionally, the radial forearm free flap has been used, however, this has significant donor site morbidity. Over the last decade, the medial sural artery perforator (MSAP) flap has emerged as a possible alternative with lower donor site morbidity. We present our experiences and review the literature regarding this promising but challenging flap. The study was a retrospective case series in a university hospital setting. All patients who had a MSAP flap performed at our institution were included until March 2015, and their data was retrieved from electronic patient records. In total, ten patients were reconstructed with a MSAP flap for floor of mouth (eight) and lower extremity (two) defect reconstruction. The median flap dimensions were as follows: 10 cm (range 7-14 cm), width 5 cm (range 3.5-8 cm), thickness 5 mm (range 4-8 mm), and pedicle length 10 cm (range 8-12 cm). In one case, the procedure was abandoned because of very small perforators and another flap was used. In two cases, late onset of venous congestion occurred which could not be salvaged. There were no donor site complaints. The MSAP flap is an ideal flap when a thin free flap is needed with lower donor site morbidity than alternative solutions. There seems to be a higher rate of late onset of venous thrombosis compared with more established flaps. Therefore, this flap should be monitored more closely for venous problems and we recommend performing two venous anastomoses when using this flap. Level of Evidence: Level IV, therapeutic study.
[APPLICATION VALUE OF INDOCYANINE GREEN ANGIOGRAPHY IN FLAP RECONSTRUCTIVE SURGERY].
Yang, Kai; Mu, Lan; Liu, Yan; Peng, Zhe; Li, Guangxue
2015-09-01
To investigate the utility of indocyanine green angiography in flap reconstructive surgery and possibility of decrease the complications. Indocyanine green angiography was performed on 14 patients undergoing flap reconstructive surgery between February and December 2014 to evaluate the blood perfusion of the flap and to adjust the operation plan. Of 14 cases, 2 were male and 12 were female, aged 23-58 years (mean, 35.5 years); 11 flaps were used for breast reconstruction [including 3 free deep inferior epigastric antery perforator (DIEP) flaps, 4 pedicled transverse rectus abdominis myocutaneous flaps (TRAM), 2 pedicled TRAM and free TRAM, and 2 pedicled latissimus dorsi myocutaneous flaps and prosthesis], 1 pedicled latissimus dorsi myocutaneous flap for repairing chest wall defect, 1 pedicled profunda artery perforator (PAP) flap for upper leg defect, and 1 pedicled descending genicular artery perforator flap for knee defect. The size of the flaps ranged from 9 cm x 6 cm to 26 cm x 12 cm. A total of 32 indocyanine green angiography were performed. There was no adverse reactions to the infusion of indocyanine green. The surgery management was adjusted according to results of indocyanine green angiography findings in 5 of 14 cases. The distal part of flap were discarded because of poor perfusion in 3 cases (1 DIEP flap, 1 TRAM, and 1 PAP flap) and the other 2 cases (pedicled TRAM) needed additional free anastomosis to ensure sufficient blood supply (pedicled TRAM and free TRAM); the other flaps were harvested according to preoperative plan and repaired defect successfully. The mean follow-up was 5 months (range, 1-9 months). The other flaps survived without infection or fat necrosis except 1 PAP flap with distal necrosis. Intraoperative indocyanine green angiography can provide real-time information of flap perfusion and then the operation plan can be adjusted in time to ensure the flap survival.
Chang, Chun-Kai; Wu, Chien-Ju; Chen, Chun-Yu; Wang, Chi-Yu; Chu, Tzi-Shiang; Hsu, Kuo-Feng; Chiu, Han-Ting; Liu, Hung-Hui; Chou, Chang-Yi; Wang, Chih-Hsin; Lin, Chin-Ta; Dai, Niann-Tzyy; Tzeng, Yuan-Sheng
2017-12-01
Pressure sores are often observed in patients who are bedridden. They can be a severe problem not only for patients and their caregivers but also for plastic surgeons. Here, we describe a new method of superior gluteal artery perforator flap harvesting and anchoring with the assistance of intraoperative indocyanine green fluorescent angiography. In this report, we describe the procedure and outcomes for 19 patients with grades III and IV sacral pressure sores who underwent the operation between September 2015 and November 2016. All flaps survived, and two experienced wound-edge partial dehiscence. With the assistance of this imaging device, we were able to acquire a reliable superior gluteal artery perforator flap and perform modified operations with it that are safe, easy to learn and associated with fewer complications than are traditional. © 2017 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Experience with peroneus brevis muscle flaps for reconstruction of distal leg and ankle defects
Bajantri, Babu; Bharathi, Ravindra; Ramkumar, Sanjai; Latheef, Latheesh; Dhane, Smitha; Sabapathy, S. Raja
2013-01-01
Objective: Peroneus brevis is a muscle in the leg which is expendable without much functional deficit. The objective of this study was to find out its usefulness in coverage of the defects of the lower leg and ankle. Patients and Methods: A retrospective analysis of the use of 39 pedicled peroneus brevis muscle flaps used for coverage of defects of the lower leg and ankle between November 2010 and December 2012 was carried out. The flaps were proximally based for defects of the lower third of the leg in 12 patients and distally based for reconstruction of defects of the ankle in 26 patients, with one patient having flaps on both ankles. Results: Partial flap loss in critical areas was found in four patients requiring further flap cover and in non-critical areas in two patients, which were managed with a skin graft. Three of the four critical losses occurred when we used it for covering defects over the medial malleolus. There was no complete flap loss in any of the patients. Conclusion: This flap has a unique vascular pattern and fails to fit into the classification of the vasculature of muscles by Mathes and Nahai. The unusual feature is an axial vessel system running down the deep aspect of the muscle and linking the perforators from the peroneal artery and anterior tibial artery, which allows it to be raised proximally or distally on a single perforator. The flap is simple to raise and safe for the reconstruction of small-to moderate-sized skin defects of the distal third of the tibia and all parts of the ankle except the medial malleolus, which is too far from the pedicle of the distally based flap. The donor site can be closed primarily to provide a linear scar. The muscle flap thins with time to provide a good result aesthetically at the primary defect. PMID:23960305
Lee, Yoon Jae; Kim, Hak Young; Han, Hyun Ho; Moon, Suk-Ho; Byeon, Jun Hee; Rhie, Jong Won; Ahn, Sang Tae; Oh, Deuk Young
2017-02-01
Reduced tissue damage is a theoretical advantage of using an ultrasonic harmonic scalpel. We hypothesized that the harmonic scalpel would outperform electrocautery in deep inferior epigastric perforator flap surgery, possibly resulting in a shorter operative time and reduced postoperative drainage and pain. Between January and August 2015, 24 consecutive patients were assigned to immediate deep inferior epigastric perforator flap elevation (12 for bipolar electrocautery and 12 for harmonic scalpel). The main outcome variables were total operative time, flap elevation time (starting from the fascia incision), and drainage volume. We compared the number of perforators isolated and the Moon and Taylor classification of the pedicle. Data were tested for normality using the Kolmogorov-Smirnov test before analysis. Continuous variables were compared by Wilcoxon rank-sum test. Data were analyzed using the statistical software SAS, version 9.3 (SAS Institute, Cary, NC, USA). Both groups were comparable with respect to clinical characteristics (mean age, body mass index, and flap weights). There was a statistically significant difference in the operative time between dissection with the harmonic scalpel and electrocautery (305.2 vs. 380.3 min, respectively, p = 0.002). The flap elevation time was reduced, particularly when using the harmonic scalpel where its usage seems crucial for dissecting deep inferior epigastric perforators (59.8 vs. 145.9 min, respectively, p < 0.0001). No statistical difference was observed in the drainage volume and length of hospital stay between the groups. We conclude that the harmonic scalpel may be more reliable and efficient as an alternative to electrocautery. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Propeller thoracodorsal artery perforator flap for breast reconstruction.
Angrigiani, Claudio; Rancati, Alberto; Escudero, Ezequiel; Artero, Guillermo; Gercovich, Gustavo; Deza, Ernesto Gil
2014-08-01
The thoracodorsal artery perforator (TDAP) flap has been described for breast reconstruction. This flap requires intramuscular dissection of the pedicle. A modification of the conventional TDAP surgical technique for breast reconstruction is described, utilizing instead a propeller TDAP flap. The authors present their clinical experience with the propeller TDAP flap in breast reconstruction alone or in combination with expanders or permanent implants. From January 2009 to February 2013, sixteen patients had breast reconstruction utilizing a propeller TDAP flap. Retrospective analysis of patient characteristics, clinical indications, procedure and outcomes were performed. The follow-up period ranged from 4 to 48 months. Sixteen patients had breast reconstruction using a TDAP flap with or without simultaneous insertion of an expander or implant. All flaps survived, while two cases required minimal resection due to distal flap necrosis, healing by second intention. There were not donor-site seromas, while minimal wound dehiscence was detected in two cases. The propeller TDAP flap appears to be safe and effective for breast reconstruction, resulting in minimal donor site morbidity. The use of this propeller flap emerges as a true alternative to the traditional TDAP flap.
Yoshimatsu, Hidehiko; Iida, Takuya; Yamamoto, Takumi; Hayashi, Akitatsu
2018-05-12
The superficial circumflex iliac artery (SCIA)-based iliac bone flap has yet to be widely used. The purpose of this article is to validate the feasibility of SCIA-based iliac bone flap transfers for reconstruction of small to moderate-sized bony defects. Retrospective outcome comparisons between SCIA-based iliac bone flaps and fibula flaps were made. Twenty-six patients with bony tissue defects underwent reconstructions using either free SCIA-based iliac bone flaps (13) or fibula flaps (13). Outcomes were evaluated 9 months after the reconstruction on the following basis: bone length, pedicle length, skin paddle area, bone union, donor-site complications, skin paddle survival, and complications at the reconstructed site. There was no statistically significant difference in pedicle length (iliac bone vs. fibula; 5.5 ± 1.8 vs. 4.1 ± 1.5 cm; p = 0.181), in bone union rate (iliac bone vs. fibula; 100 vs 92.3%; p = 0.308), in donor-site complication rate (iliac bone vs. fibula; 0 vs. 7.7%; p = 0.308), or in skin paddle complete survival rate (iliac bone vs. fibula; 100 vs. 83.3%; p = 0.125). Statistically significant differences were observed in bone flap length (iliac bone vs. fibula; 4.8 ± 2.2 vs. 11.1 ± 4.8 cm; p = 0.0005), in skin paddle area (superficial circumflex iliac artery perforator flap vs. peroneal artery perforator flap; 58.8 ± 35.6 vs. 27.7 ± 17.5 cm 2 ; p = 0.0343), and in reconstructed site complication rate (iliac bone vs. fibula; 0 vs. 30.8%; p = 0.030). In our series of SCIA-based iliac bone flap transfers, up to 8 × 3 cm could be procured along the iliac crest. When compared with fibula flap transfers, there were no significant statistical differences in pedicle length or in bone union rate; the SCIA-based iliac bone flap may be a feasible option for bony defects of small to moderate size. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Brunetti, Beniamino; Tenna, Stefania; Poccia, Igor; Persichetti, Paolo
2017-02-01
Despite of the widespread use of 180-degree propeller flaps in the field of soft tissue reconstruction, less information are available in the current literature to standardize the use of propeller flaps with reduced degrees of rotation.The authors report their experience with propeller flaps with reduced rotational angles reviewing clinical applications and outcomes of the technique in a series of 40 consecutive reconstructions. Forty elective defects of various etiologies located in different regions of the body (head and neck, trunk, buttocks and perineum, extremities) were reconstructed with less than 180 degrees rotated propeller flaps. The technique was applied to patients presenting with a strong audible perforator detected in close proximity to the wound and the defect located in a position adjacent to the axis of the chosen perforasome. Defect size ranged from 2 × 2 to 15 × 9 cm. Flap dimensions ranged from 5 × 2 to 21 × 10 cm. The flaps were based on 1 (34) or 2 (6) perforators and were mobilized with an angle of rotation of 45, 90, and 135 degrees in 7, 24, and 9 patients, respectively. Mean operative time was 105 minutes. All flaps survived postoperatively. In only 4 cases (10%) partial flap necrosis was registered. All flaps achieved adequate and durable reconstruction with excellent contour, with a follow-up ranging between 6 months and 2 years. Propeller flaps with reduced rotational angles represent a safe and versatile option to reconstruct soft tissues defects at different anatomical sites.
Perforator Propeller Flaps for the Coverage of Middle and Distal Leg Soft-tissue Defects
Cabrera, Rodrigo; Siu, Armando; Altamirano, Roderick; Gutierrez, Sandra
2018-01-01
Background: Local propeller flaps preserve the main vascular arteries of the lower extremity and muscle function, avoiding the need for a microsurgical anastomosis and the benefit of providing a “like with like” coverage. Our goal in this study was to demonstrate the versatility, safety, and complications of the local propeller flaps for lower extremity reconstruction. Methods: We present a series of 28 patients in whom we used local propeller flaps to restore small-to-medium soft-tissue defects of the lower limb in different hospitals of Managua, Nicaragua. Results: Flap average dimensions were of 48 cm2. Flap rotation was performed in 180 degrees in 85% of the cases. The propeller flaps were based on a single perforator, from the posterior tibial artery in 50%, anterior tibial artery in 39.3%, and peroneal artery in 10.7% of the cases. Complications occurred in 14% of the propeller flaps performed, with 3 partial necrosis of less than 15% of the flap transposed. Complications of the patients occurred in both sex groups; however, for the female group, there was a 75% of complications with a tendency toward statistical significance of P = 0.038. Donor site of the flap was closed primarily in 85.7% (24) of the cases. Conclusions: In our opinion, the availability and safety of local propeller flaps, justifies its use in cases where microsurgical techniques are not an option for the reconstruction of the middle and distal extremity, in small-to-medium defects of soft-tissue coverage of the lower limb. PMID:29922552
The superior gluteal artery perforator flap for reconstruction of sacral sores
Chen, Weijian; Jiang, Bo; Zhao, Jiaju; Wang, Peiji
2016-01-01
This report describes our experiences using the superior gluteal artery perforator (SGAP) flaps for reconstruction of 2 sacral sore cases. A 47-year-old female patient and a 38-year-old man with sacral sores were treated in our unit. The size of the defects were approximately 5×6 cm2 and 8×9 cm2, the defects were repaired by SGAP flaps. The size of designed was SGAP flaps varied from 7×20 to 9×16 cm2. All flaps survived and healed primary, the texture, functions, and appearance of flaps were satisfactory, and also without region dysfunction of donor and recipient sites. The SGAP flap, which has reliable blood supply, preserves the gluteus maximus muscle and could be transferred simply and safely, is an ideal and reusable method to reconstruct sacral sores with low rate of postoperative recurrence and satisfactory appearance. PMID:27652367
Ruiz-Moya, A; Lagares-Borrego, A; Infante-Cossío, P
2015-04-01
Facial cutaneous oncological pathology often involves more than one esthetic unit due to their close boundaries. The reconstruction of both the nasolabial and perinasal regions may be especially complex and challenging for the surgeon. Traditionally, these defects have been reconstructed with local random flaps based on the vascularization provided by the superficial musculoaponeurotic system. In this article, we present our experience in the reconstruction of the aforementioned defects using the propeller facial artery perforator (FAP) flap. A propeller FAP flap was performed for reconstruction in 12 patients with nasolabial or perinasal complex defects after tumoral resection between the years 2011 and 2013. The flap was designed parallel to the nasolabial fold in all cases for achieving direct closure and an aesthetically pleasing outcome. In one of the cases, a paramedian forehead flap was performed simultaneously. Nine patients healed uneventfully, with good functional and esthetic outcomes. One of the flaps developed partial necrosis of the distal end, and another developed temporary postoperative venous congestion, lymphedema, and, finally, trapdoor deformity. The latter complication also occurred in one more flap. The propeller FAP flap is reliable and versatile, with few complications, and it is especially useful when reconstructing complex defects that involve the nasolabial and perinasal regions; therefore, it should be considered as one of the first reconstructive options for the described defects. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Routine preoperative colour Doppler duplex ultrasound scanning in anterolateral thigh flaps.
Lichte, Johanna; Teichmann, Jan; Loberg, Christina; Kloss-Brandstätter, Anita; Bartella, Alexander; Steiner, Timm; Modabber, Ali; Hölzle, Frank; Lethaus, Bernd
2016-10-01
The anterolateral thigh flap (ALT) is often used to reconstruct the head and neck and depends on one or more skin perforators, which often present with variable anatomy. The aim of this study was to localise and evaluate the precise position of these perforators preoperatively with colour Doppler duplex ultrasound scanning (US). We detected 74 perforators in 30 patients. The mean duration of examination with colour Doppler was 29 (range 13-51) minutes. Adequate perforators and their anatomical course could be detected preoperatively extremely accurately (p<0.001). The mean difference between the preoperatively marked, and the real, positions was 6.3 (range 0-16) mm. There was a highly significant correlation between the accuracy of the prediction and the body mass index of the patient (0.75; p<0.001). Neither the age nor the sex of the patient correlated with the accuracy of the prediction. Colour Doppler duplex US used preoperatively to localise perforators in ALT flaps is reliable and could be adopted as standard procedure. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Chae, Michael P; Hunter-Smith, David J; Rostek, Marie; Smith, Julian A; Rozen, Warren Matthew
2018-01-01
Optimizing preoperative planning is widely sought in deep inferior epigastric artery perforator (DIEP) flap surgery. One reason for this is that rates of fat necrosis remain relatively high (up to 35%), and that adjusting flap design by an improved understanding of individual perforasomes and perfusion characteristics may be useful in reducing the risk of fat necrosis. Imaging techniques have substantially improved over the past decade, and with recent advances in 3D printing, an improved demonstration of imaged anatomy has become available. We describe a 3D-printed template that can be used preoperatively to mark out a patient's individualized perforasome for flap planning in DIEP flap surgery. We describe this "perforasome template" technique in a case of a 46-year-old woman undergoing immediate unilateral breast reconstruction with a DIEP flap. Routine preoperative computed tomographic angiography was performed, with open-source software (3D Slicer, Autodesk MeshMixer and Cura) and a desktop 3D printer (Ultimaker 3E) used to create a template used to mark intra-flap, subcutaneous branches of deep inferior epigastric artery (DIEA) perforators on the abdomen. An individualized 3D printed template was used to estimate the size and boundaries of a perforasome and perfusion map. The information was used to aid flap design. We describe a new technique of 3D printing a patient-specific perforasome template that can be used preoperatively to infer perforasomes and aid flap design.
Hunter-Smith, David J.; Rostek, Marie; Smith, Julian A.; Rozen, Warren Matthew
2018-01-01
Summary: Optimizing preoperative planning is widely sought in deep inferior epigastric artery perforator (DIEP) flap surgery. One reason for this is that rates of fat necrosis remain relatively high (up to 35%), and that adjusting flap design by an improved understanding of individual perforasomes and perfusion characteristics may be useful in reducing the risk of fat necrosis. Imaging techniques have substantially improved over the past decade, and with recent advances in 3D printing, an improved demonstration of imaged anatomy has become available. We describe a 3D-printed template that can be used preoperatively to mark out a patient’s individualized perforasome for flap planning in DIEP flap surgery. We describe this “perforasome template” technique in a case of a 46-year-old woman undergoing immediate unilateral breast reconstruction with a DIEP flap. Routine preoperative computed tomographic angiography was performed, with open-source software (3D Slicer, Autodesk MeshMixer and Cura) and a desktop 3D printer (Ultimaker 3E) used to create a template used to mark intra-flap, subcutaneous branches of deep inferior epigastric artery (DIEA) perforators on the abdomen. An individualized 3D printed template was used to estimate the size and boundaries of a perforasome and perfusion map. The information was used to aid flap design. We describe a new technique of 3D printing a patient-specific perforasome template that can be used preoperatively to infer perforasomes and aid flap design. PMID:29464169
Sheriff, Hemin Oathman; Mahmood, Kawa Abdullah; Hamawandi, Nzar; Mirza, Aram Jamal; Hawas, Jawad; Moreno, Esther Granell; Clavero, Juan Antonio; Hankins, Christopher; Masia, Jaume
2018-05-18
The supraclavicular artery flap is an excellent flap for head and neck reconstruction. The aim of this study is to assess imaging techniques to define the precise vascular boundaries of this flap. Six imaging techniques were used for supraclavicular artery mapping in 65 cases; handheld Doppler, triplex ultrasound, computed tomography angiography, magnetic resonance angiography, digital subtraction angiography, and indocyanine green angiography. We checked the site of the perforators, the course of a supraclavicular artery, and anatomical mapping of the supraclavicular artery. Handheld Doppler identified perforators' sites in 80% of the cases but showed no results for the course of the vessel. Triplex ultrasound identified the site of perforators in 52.9%, and partial mapping of the course of a supraclavicular artery in 64.7% of the cases. Computerized tomography angiography showed the site of perforators in 60%, and the course of supraclavicular artery completely in 45%, and partially in an additional 30%of the cases examined. Magnetic resonance angiography showed negative results for all parameters. Digital subtraction angiography showed the partial course of a supraclavicular artery in 62.5%, but showed no perforators. Indocyanine green angiography showed the site of perforators in 60% and a partial course of supraclavicular artery distal to perforators in 60%.Anatomical mapping of the vessel was possible with computerized tomography angiogram completely in 45%, and partially in 30%, and was also possible with indocyanine green angiography partially in 60%. Computerized tomography angiography showed best results in the mapping of the supraclavicular artery, but with an inability to define the perforator perfusion territories, and also with risks of irradiation, while indocyanine green angiography is a good alternative as it could precisely map the superficial course of the artery and angiosomes, with no radiation exposure. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Tang, Xiujun; Wang, Bo; Wei, Zairong; Wang, Dali; Han, Wenjie; Zhang, Wenduo; Li, Shujun
2015-12-01
OBJECTIVE To explore the feasibility and effectiveness of V-Y advanced sense-remained posterior tibial artery perforator flap in repairing wound around the ankle. METHODS Between March 2012 and January 2015, 11 patients with wounds around the ankle were treated by V-Y advanced sense-remained posterior tibial artery perforator flap. There were 6 males and 5 females with a median age of 37 years (range, 21-56 years). The causes were traffic accident injury in 3 cases, thermal injury in 2 cases, burn in 2 cases, iatrogenic wounds in 2 cases, and local contusion in 2 cases. The disease duration ranged from 1 to 3 weeks (mean, 2 weeks). Injury was located at the medial malleolus in 4 cases, at the lateral malleolus in 3 cases, and at the heel in 4 cases. All had exposure of bone, tendon, or plate. The defect area ranged from 4 cmx2 cm to 5 cmx3 cm; the area of the flap ranged from 11 cmx4 cm to 15 cmx6 cm. Necrosis of distal flap occurred in 1 case after operation; re-operation to amputate the posterior tibial artery was given and the wound was repaired by proximal skin graft. Light necrosis of distal end was observed in 2 cases, and wound healed at 3 weeks after dressing. And other flaps successfully survived, and primary healing of wounds were obtained. The patients were followed up 6-24 months (mean, 11 months). The flaps were good in color, texture, and appearance. The ankle joint had normal activity. At last follow-up, 10 cases restored fine sense, and 1 case restored protective feeling with posterior tibial artery advanced flap after amputation. V-Y advanced sense-remained posterior tibial artery perforator flap has the advantages of reliable blood supply, simple operation, good appearance, and sensory recovery. Therefore, it is an ideal method to repair wound around the ankle.
[Localization of perforators in the lower leg by digital antomy imaging methods].
Wei, Peng; Ma, Liang-Liang; Fang, Ye-Dong; Xia, Wei-Zhi; Ding, Mao-Chao; Mei, Jin
2012-03-01
To offer both the accurate three-dimensional anatomical information and algorithmic morphology of perforators in the lower leg for perforator flaps design. The cadaver was injected with a modified lead oxide-gelatin mixture. Radiography was first performed and the images were analyzed using the software Photoshop and Scion Image. Then spiral CT scan was also performed and 3-dimensional images were reconstructed with MIMICS 10.01 software. There are (27 +/- 4) perforators whose outer diameter > or = 0.5 mm ( average, 0.8 +/- 0.2 mm). The average pedicle length within the superficial fascia is (37.3 +/- 18.6) mm. The average supplied area of each perforator is (49.5 +/- 25.5) cm2. The three-dimensional model displayed accurate morphology structure and three-dimensional distribution of the perforator-to- perforator and perforator-to-source artery. The 3D reconstruction model can clearly show the geometric, local details and three-dimensional distribution. It is a considerable method for the study of morphological characteristics of the individual perforators in human calf and preoperative planning of the perforator flap.
Free anterolateral thigh flap for reconstruction of major craniofacial defects.
Amin, Ayman; Rifaat, Mohammed; Civantos, Francisco; Weed, Donald; Abu-Sedira, Mohammed; Bassiouny, Mahmoud
2006-02-01
Free-tissue transfer has revolutionized skull-base surgery by expanding the ability to perform cranial base resection and by improving the quality of reconstruction. The anterolateral thigh flap has come recently into use in the field of head and neck reconstruction. Its role in craniofacial and midface reconstruction has not been specifically defined. This study involved a total of 18 patients who were treated over a 5-year period from 1998 to 2003. Seventeen patients had locally advanced head and neck cancer, requiring craniofacial resection, and one patient had a complicated gun shot wound of the forehead. Thirteen patients were treated at the National Cancer Institute, Cairo University, Egypt, and five patients at the University of Miami, Florida. The patients presented with defects of the anterior skull base (5), lateral skull base (3), scalp and calvarium (3), and the midface (7). The anterolateral thigh flap was used as a myocutaneous flap in 11 cases and as a perforator fasciocutaneous flap in seven cases. Musculocutaneous perforators supplied the majority of flaps (17/18). Total flap survival occurred in 17 cases; one patient developed complete flap necrosis. The most commonly used recipient vessels were the facial vessels and the external jugular vein. Major complications included one case with meningitis; the patient died after failure of treatment. Another patient died 6 weeks postoperatively from pulmonary embolism. One patient developed CSF leak that stopped spontaneously. In addition, two patients developed minor wound dehiscence that healed spontaneously. The donor-site wound healed without problems except in two cases. One patient had an incomplete take of the skin graft; the other developed wound infection and superficial sloughing. Both wounds healed spontaneously. In addition to the feasibility of simultaneous flap harvesting with tumor resection, the flap's advantage in skull base reconstruction is its reliable blood supply, which can provide adequate dural cover and protection of the brain. Its size and moderate thickness are suitable for reconstruction of scalp and calvarial defects. The abundance of reliably vascularized fat in the flap may be an advantage in long-term maintenance of the volume of the flap in midface reconstruction. Similar to other soft tissue flaps, additional skeletal reconstruction may still be required to achieve an optimal functional and aesthetic result.
Triple flap technique for vulvar reconstruction.
Mercut, R; Sinna, R; Vaucher, R; Giroux, P A; Assaf, N; Lari, A; Dast, S
2018-04-09
Perineal defects are encountered ever more frequently, in the treatment of vulvar cancers or abdominoperineal resection. The surgical treatment of vulvar cancer leads to significant skin defect. The aim of the reconstruction is not to provide volume but rather to resurface perineum. We propose a new solution to cover the extensive skin defect remaining after excision. We report 3 patients who underwent large excision for vulvar cancer, with lymph node dissection. For reconstruction, we performed 3 advancement flaps. Two V-Y flaps cantered on the infra-gluteal folds and based on pudendal perforator arteries were used to cover the postero-lateral parts of the defect. The third advancement flap from the superior aspect of the defect was a Y-V Mons pubis flap. The defects were successfully covered by the 3 flap technique. The first patient suffered a non-union that slowly healed by secondary intention. For the other cases, we used the same technique, but applied negative pressure wound therapy on the sutures, with excellent results. The 3 flap technique is a simple and reliable method and the donor site morbidity is minimal. It can be realised without changing the position of the patient after tumour excision, and does not require delicate perforator dissection. This surgical option can be easily applied, allowing better management of these cases. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Effect of fibrin sealant in positioning and stabilizing microvascular pedicle: A comparative study.
Kim, Jeong Tae; Kim, Youn Hwan; Kim, Sang Wha
2017-07-01
Fibrin sealants have had applications in hemostasis, cohesion, and promotion of healing in plastic surgery. In this article, we review cases where fibrin sealant was used to stabilize microvascular pedicles and compared with previous free flaps performed without fibrin sealant. Between 2008 and 2010, 62 consecutive patients underwent free tissue transfer for reconstruction; this involved 33 latissimus dorsi perforator flaps, 14 thoracodorsal artery perforator flaps, 9 latissimus dorsi myocutaneous flaps, 3 lateral thoracic artery perforator flaps, and 3 transverse rectus abdominis myocutaneous flaps, used in head and neck reconstruction, lower limb reconstructions, breast reconstructions, and facial palsy reconstruction. Following microvascular anastomosis, the microvascular pedicles were placed in the optimal position, and fibrin sealant was used to fix and stabilize them. The complications, such as venous thrombosis, arterial thrombosis, hematoma, and vascular pedicle kinking, were compared with that of 672 previous free flaps without fibrin sealant for stabilizing microvascular pedicles. Among the 62 free tissue transfers using fibrin sealant, there was only one complication involving flap failure (1.6%), in this case due to venous thrombosis. Analysis of 672 free flaps performed without application of fibrin sealant revealed 24 complications (3.6%), due to 3 venous thrombosis, 1 arterial thrombosis, 4 vascular pedicel compression due to hematoma, and 16 pedicle kinking. However, the comparison of complications between the free flap using fibrin sealant and the free flap without fibrin sealant were not statistically significant (P = 0.65). Fibrin sealant can be used to prevent vascular kinking and to position anastomosed vessels after successful micro-anastomosis and allow the reconstructive surgeon to overcome challenging situations of vascular pedicle related complications © 2016 Wiley Periodicals, Inc. Microsurgery 37:406-409, 2017. © 2016 Wiley Periodicals, Inc.
Hocaoğlu, Emre
2014-01-01
Prefabrication of supraclavicular skin provides a useful source for flaps congruent with the face skin. Among various vascular sources that have been used for this purpose, anterolateral thigh fascia seems to represent a greater value because of having a long and strong vascular pedicle and negligible donor-site morbidity. In this regard, we present a technical report on using the lateral circumflex femoral artery perforator flap harvest technique in preparing an anterolateral thigh fascia flap for the prefabrication of the supraclavicular skin. The technique proved successful in resurfacing the facial skin of a young female patient with a giant congenital melanocytic hairy nevus on the left side of her face.
Ling, Barbara M; Wettstein, Reto; Staub, Daniel; Schaefer, Dirk J; Kalbermatten, Daniel F
2018-02-07
The gastrocnemius muscle flap may be considered the first choice in many cases of soft-tissue reconstruction about the knee. Limited arc of rotation and reach of the flap as well as unsightly muscle bulk are major disadvantages and were the impetus to look for a local alternative. The aim of this study is to present a consecutive series of patients with a reconstruction about the knee involving the medial sural artery perforator flap (MSAPF). A consecutive series of 17 cases of defect reconstructions about the knee using the MSAPF is described, with an emphasis on early postoperative complications. No major flap-related complications occurred except 1 case of tip necrosis that healed uneventfully after excision and secondary suture. Two patients with direct donor-site closure had a minor complication that required no revision, and 2 had partial skin-graft loss. In summary, use of this pedicled perforator flap represents a reliable technique for soft-tissue reconstruction about the knee with an acceptable complication rate and optimal contour reconstruction without the need for a skin graft and secondary debulking procedures. The range of motion associated with the MSAPF in comparison to the range associated with the gastrocnemius muscle flap is increased so that more proximal and lateral defects can be covered. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Lanni, Michael Alan; Van Kouwenberg, Emily; Yan, Alan; Rezak, Kristen M; Patel, Ashit
2017-07-01
The keystone design perforator island flap has been gaining popularity for reconstruction of cutaneous defects. Published experience of this technique in North America is limited predominantly to the trunk and extremities; our study aims to demonstrate expanding applications. Retrospective chart review was conducted on all patients who underwent keystone flap reconstruction by a single surgeon. Outcomes of interest were wound healing complications (WHC) and surgical site infections (SSI). Mean follow up time was 24.4 months. Sixty consecutive flaps were performed with an overall WHC rate of 26.7% and SSI rate of 11.7%. Reconstructed sites included 25 lower extremity, 20 trunk, 5 upper extremity, and 10 head and neck. Flap size averaged 405.6 cm (range 16-2303). Wound healing complications were associated with coronary artery disease (P = 0.04) and traumatic defects (P = 0.043). Surgical site infections were associated with coronary artery disease (P = 0.02) and flap size of 251 to 500 cm (P = 0.039), although this association was not seen among flaps greater than 500 cm. Although more common in lower extremity reconstructions, no statistically significant associations between flap location and WHC (P = 0.055) or SSI (P = 0.29) were identified. There were no reconstructive failures and no patients required reoperation. This series demonstrates the versatility of the keystone flap in a wide variety of anatomic locations, with similar complication rates to those previously reported and no reoperations. Flap design was frequently modified based on the anatomical topography and adjacent subunits. To our knowledge, this is the largest and most diverse North American series of keystone flap reconstructions to date.
Tan, Shane; Yek, Jacklyn; Ong, Wei Chen; Hing, Chor Hoong; Lim, Thiam Chye
2013-01-01
Background Our objective was to compare the complication rates of two common breast reconstruction techniques performed at our hospital and the cost-effectiveness for each test group. Methods All patients who underwent deep inferior epigastric perforator (DIEP) flap and transverse rectus abdominis myocutaneous (TRAM) flap by the same surgeon were selected and matched according to age and mastectomy with or without axillary clearance. Patients from each resultant group were selected, with the patients matched chronologically. The remainder were matched for by co-morbidities. Sixteen patients who underwent immediate breast reconstruction with pedicled TRAM flaps and 16 patients with DIEP flaps from 1999 to 2006 were accrued. The average total hospitalisation cost, length of hospitalisation, and complications in the 2 year duration after surgery for each group were compared. Results Complications arising from both the pedicled TRAM flaps and DIEP flaps included fat necrosis (TRAM, 3/16; DIEP, 4/16) and other minor complications (TRAM, 3/16; DIEP, 1/16). The mean hospital stay was 7.13 days (range, 4 to 12 days) for the pedicled TRAM group and 7.56 (range, 5 to 10 days) for the DIEP group. Neither the difference in complication rates nor in hospital stay duration were statistically significant. The total hospitalisation cost for the DIEP group was significantly higher than that of the pedicled TRAM group (P<0.001). Conclusions Based on our study, the pedicled TRAM flap remains a cost-effective technique in breast reconstruction when compared to the newer, more expensive and tedious DIEP flap. PMID:23730591
[Applied anatomy of small saphenous vein and its distally-based sural nerve nutrient].
Zhang, Fahui; Lin, Songqing; Zheng, Heping
2005-07-01
To investigate the origin of small saphenous vein of distally-based of sural nerve nutrient vessels flap and its clinical application. The origins of nutrient vessels of small saphenous vein and communicating branches of superficial-deep vein were observed on specimens of 30 adult cadaveric low limbs by perfusing red gelatin to dissect the artery. The nutrient vessels of small saphenous vein originated from the heel lateral artery, the terminal perforator branches of peroneal artery and intermuscular septum perforating branches of peroneal artery. There were 2 to 5 branches of such distally-based perforating branches whose diameters ranged from 0.6 to 1.0 mm. Those perforating branches included fascia branches, cutaneous branches nerve and vein nutrient branches. Those nutrient vessels formed a longitudinal vessel chain of clinical nerve shaft, vessel chain of vein side and vessel network of deep superficial fascia. The small saphenous vein had 1 to 2 communicating branches of superficial-deep vein whose diameter was 1.7+/-0.5 mm, 3.4+/-0.9 cm to the level of cusp of lateral malleolus, and converged into the fibular vein. Distally-based sural nerve, small saphenous vein, and nutrient vessels of fascia skin have the same region. The communicating branches of superficial-deep vein is 3 to 4 cm to the level of cusp lateral malleolus. These communicating branches could improve the venous drainage of the flap.
Laser-assisted indocyanine green angiography: a critical appraisal.
Wu, Cindy; Kim, Sendia; Halvorson, Eric G
2013-05-01
Laser-assisted indocyanine green angiography (ICG-A) has been promoted to assess perfusion of random skin, pedicled, and free flaps. Few studies address its potential limitations. Thirty-seven patients who underwent reconstructive procedures with ICG-A were studied retrospectively to determine the correlation between clinical findings and ICG-A. Indocyanine green angiography underestimated perfusion when areas of less than or equal to 25% uptake were not debrided and remained perfused. Indocyanine green angiography overestimated perfusion when areas with greater than 25% uptake developed necrosis. Of 14 random skin flaps, ICG-A underestimated perfusion in 14% and overestimated in 14%. In 16 patients undergoing perforator flap breast reconstruction, ICG-A correlated with computed tomographic angiogram (CTA) in 85%. Indocyanine green angiography underestimated perfusion in 7% and overestimated in 7%. In 8/11 patients undergoing fasciocutaneous flaps, ICG-A aided in donor site selection. In 3/6 ALT flaps, a better unilateral blush was found that correlated with Doppler. In all 3, a dominant perforator was found. In 11 patients, there was a 9% underestimation of flap perfusion. In 3 pedicled flaps, there was a 66% underestimation and 33% overestimation of perfusion. Indocyanine green angiography often confirmed our clinical/radiologic findings in abdominal perforator and fasciocutaneous flaps. It tended to underestimate perfusion in pedicle and skin flaps. When clinical examination was obvious, ICG-A rendered clear-cut findings. When clinical examination was equivocal, ICG-A tended to provide ambiguous findings, demonstrating that a distinct cutoff point does not exists for every patient or flap. Indocyanine green angiography is a promising but expensive technology that would benefit from standardization. Further research is needed before ICG-A can become a reliable tool for surgeons.
Inferior gluteal artery perforator flap: a viable alternative for ischial pressure sores.
Kim, Young Seok; Lew, Dae Hyun; Roh, Tai Suk; Yoo, Won Min; Lee, Won Jai; Tark, Kwan Chul
2009-10-01
The ischial area is by far the most common site for pressure sores in wheelchair-bound paraplegic patients, because most of the pressure of the body is exerted on this area in the seated position. Even after a series of successful pressure sore treatments, the site is very prone to relapse from the simplest everyday tasks. Therefore, it is crucial to preserve the main pedicle during primary surgery. Several surgical procedures, such as myocutaneous flap and perforator flap, have been introduced for the treatment of pressure sores. During a 4-year time period at our institute, we found favourable clinical results using the inferior gluteal artery perforator (IGAP) procedure for ischial sore treatment. A total of 23 patients (20 males and three females) received IGAP flap surgery in our hospital from January 2003 to January 2007. Surgery was performed on the same site again in 10 (43%) patients who had originally relapsed after undergoing the conventional method of pressure sore surgery. The average age of patients was 47.4 years (range 26-71 years). Most of the patients were paraplegic (16 cases, 70%) and others were either quadriplegic (four cases, 17%) or ambulatory (three cases, 13%). Based on hospital records and clinical photographs, we attempted to assess the feasibility and practicability of the IGAP flap procedure through comparative analysis of several parameters including the size of the defective area, treatment modalities, relapses, complications, and postoperative treatments. The average follow-up duration for 23 subjects was 25.4 months (range 5-42 months). All flaps survived without major complications. Partial flap necrosis developed in one case but secondary healing was achieved and the final outcome was not impaired. Most of the cases healed well during the follow-up period. Postoperative complications such as wound dehiscence and fistula developed in some subjects, but all healed well with a secondary treatment. A total of five cases relapsed after surgery due to tissue deficit and these were treated with bursectomy and muscle transposition flap to fill the dead space. We propose that the IGAP flap should be considered a viable alternative to other methods of ischial pressure sore surgery owing to its many advantages, which include the ability to preserve peripheral muscle tissue, the variability of flap designs, relatively good durability, and the low donor site morbidity rate.
DeFazio, Michael Vincent; Han, Kevin Dong
2014-01-01
The composite anterolateral thigh flap with vascularized fascia lata has emerged as a workhorse at our institution for complex Achilles defects requiring both tendon and soft tissue reconstruction. Safe elevation of this flap, however, is occasionally challenged by absent or inadequate perforators supplying the anterolateral thigh. When discovered intraoperatively, alternative options derived from the same vascular network can be pursued. We present the case of a 74-year-old male who underwent composite Achilles defect reconstruction using a segmental rectus femoris myofascial free flap. Following graduated rehabilitation, postoperatively, the patient resumed full activity and was able to ambulate on his tip-toes. At 1-year follow-up, active total range of motion of the reconstructed ankle exceeded 85% of the unaffected side, and donor site morbidity was negligible. American Orthopaedic Foot and Ankle Society and Short Form-36 scores improved by 78.8% and 28.8%, respectively, compared to preoperative baseline assessments. Based on our findings, we advocate for use of the combined rectus femoris myofascial free flap as a rescue option for reconstructing composite Achilles tendon/posterior leg defects in the setting of inadequate anterolateral thigh perforators. To our knowledge, this is the first report to describe use of this flap for such an indication. PMID:24883281
Qassemyar, Quentin; Assouly, Nathaniel; Madar, Yoni; Temam, Stéphane; Kolb, Frédéric
2018-02-21
Total nasal reconstruction is a challenging surgical procedure which usually involves a free flap, forehead flap, and cartilage grafts. In certain failure situations where patients do not accept the idea of anaplastology, possibilities become very limited. We report the case of a patient who underwent several reconstruction steps with multiple failures including free and local flaps and cartilage harvests which showed recurrent episodes of necrosis and infection leading to melting and collapse of reconstructed structures. Furthermore, the patient did not want any anaplastological rehabilitation. We proposed to the patient an innovative method that consists to print a three-dimensional custom-made porous titanium prosthesis, based on the original shape of his nose, to replace the cartilage support. This implant was first inserted in a thoracodorsal artery perforator flap for primary integration before the free transfer of the complete structure, two months later. The free transfer was successful without any complication. A stable reconstruction and satisfying result was obtained. The patient did not want additional surgical improvement 24 months post-operatively, and resumed his professional activities. The possibility of using three-dimensional custom titanium prostheses to replace the bone and cartilage support seems to be an interesting alternative for patients in the failure situation of nasal reconstruction. © 2018 Wiley Periodicals, Inc.
Four-flap Breast Reconstruction: Bilateral Stacked DIEP and PAP Flaps
Mayo, James L.; Allen, Robert J.
2015-01-01
Background: In cases of bilateral breast reconstruction when the deep inferior epigastric perforator (DIEP) free flap alone does not provide sufficient volume for body-specific reconstruction, stacking each DIEP flap with a second free flap will deliver added volume and maintain a purely autologous reconstruction. Stacking the profunda artery perforator (PAP) flap with the DIEP flap offers favorable aesthetics and ideal operative efficiency. We present the indications, technique, and outcomes of our experience with 4-flap breast reconstruction using stacked DIEP/PAP flaps. Methods: The authors performed 4-flap DIEP/PAP breast reconstruction in 20 patients who required bilateral reconstruction without adequate single donor flap volume. The timing of reconstruction, average mastectomy/flap weights, and operative time are reported. Complications reviewed include fat necrosis, dehiscence, hematoma, seroma, mastectomy flap necrosis, and flap loss. Results: Twenty patients underwent 4-flap DIEP/PAP breast reconstruction. Surgical time averaged 7 hours and 20 minutes. The primary recipient vessels were the antegrade and retrograde internal mammary vessels. No flap losses occurred. Complications included 1 hematoma, 1 incidence of arterial and venous thrombosis successfully treated with anastomotic revision, 1 incidence of thigh donor site dehiscence, and 3 episodes of minor mastectomy skin flap necrosis. Conclusions: Four-flap breast reconstruction is a favorable autologous reconstructive option for patients requiring bilateral reconstruction without adequate single donor flap volume. Stacking DIEP/PAP flaps as described is both safe and efficient. Furthermore, this combination provides superior aesthetics mirroring the natural geometry of the breast. Bilateral stacked DIEP/PAP flaps represent our first choice for breast reconstruction in this patient population. PMID:26090273
Rozen, Warren M; Chubb, Daniel; Ashton, Mark W; Webster, Howard R
2012-05-01
The use of advanced imaging technologies such as computed tomographic angiography (CTA) has opened the door to the analysis of microvascular anatomy not previously demonstrable with prior imaging techniques. While CTA has been used to evaluate the vascular anatomy of donor body regions in the planning of harvest of tissue for free flap transfer, the use of CTA to evaluate tissues after tissue transplantation has not been demonstrated. The current study aimed to explore whether vascular anatomy was able to highlight CTA within transferred flaps. The arterial and venous anatomy of a transferred deep inferior epigastric artery (DIEA) perforator (DIEP) flap was explored postoperatively with the use of CTA. Intra-flap vasculature was mapped and recorded qualitatively. Postoperative CTA is able to highlight the vascular pedicle of a transferred free flap, highlight the course of individual perforators supplying the flap, and map the zones of lesser perfusion by the source pedicle. The current study has demonstrated that CTA may be of value in identifying vascular anatomy within transferred tissue, as a guide to evaluate flap perfusion and planning further surgery involving the flap. © Springer-Verlag 2011
Niumsawatt, Vachara; Debrotwir, Andrew N; Rozen, Warren Matthew
2014-01-01
Computed tomographic angiography (CTA) has become a mainstay in preoperative perforator flap planning in the modern era of reconstructive surgery. However, the increased use of CTA does raise the concern of radiation exposure to patients. Several techniques have been developed to decrease radiation dosage without compromising image quality, with varying results. The most recent advance is in the improvement of image reconstruction using an adaptive statistical iterative reconstruction (ASIR) algorithm. We sought to evaluate the image quality of ASIR in preoperative deep inferior epigastric perforator (DIEP) flap surgery, through a direct comparison with conventional filtered back projection (FBP) images. A prospective review of 60 consecutive ASIR and 60 consecutive FBP CTA images using similar protocol (except for radiation dosage) was undertaken, analyzed by 2 independent reviewers. In both groups, we were able to accurately identify axial arteries and their perforators. Subjective analysis of image quality demonstrated no statistically significant difference between techniques. ASIR can thus be used for preoperative imaging with similar image quality to FBP, but with a 60% reduction in radiation delivery to patients.
Peng, Feng; Chen, Lin; Han, Dong; Xiao, Chenwei; Bao, Qiyuan; Wang, Tao
2013-11-01
We presented our experience on the use of anterolateral thigh (ALT) chimeric flap to reconstruct two separate defects in upper extremity. From December 2009 to August 2012, we used this ALT chimeric flap to reconstruct two separate defects in upper extremity on five patients (mean age: 36.6 years; range: 15 ∼ 47 years). The locations of defect were palm and fingers in four patients and forearm in the other patient. The sizes of defect ranged from 4.5 × 1.5 cm to 20 × 10 cm. A minimum of two separate perforator vessels in the flap were identified. The skin paddle was then split between the two perforators to shape two separate paddles with a common vascular supply. There were no cases of flap failure or re-exploration. Four donor sites were directly closed and one was covered by a skin graft. Donor-site morbidity was negligible. The ALT chimeric flap provides customized cover for two separate defects in upper extremity. Copyright © 2013 Wiley Periodicals, Inc.
Hayashida, Kenji; Saijo, Hiroto; Fujioka, Masaki
2018-01-01
We describe the use of a composite flap composed of a sural neurofasciocutaneous flap and a vascularized peroneus longus tendon for the reconstruction of severe composite forearm tissue defects in a patient. A 43-year-old man had his left arm caught in a conveyor belt resulting in a large soft-tissue defect of 18 × 11 cm over the dorsum forearm. The extensor carpi radialis, superficial radial nerve, and radial artery were severely damaged. A free neurofasciocutaneous composite flap measuring 16 × 11 cm was outlined on the patient's left lower leg to allow simultaneous skin, tendon, nerve, and artery reconstruction. The flap, which included the peroneus longus tendon, was elevated on the subfascial plane. After the flap was transferred to the recipient site, the peroneal artery was anastomosed to the radial artery in a flow-through manner. The vascularized tendon graft with 15 cm in length was used to reconstruct the extensor carpi radialis longus tendon defect using an interlacing suture technique. As the skin paddle of the sural neurofasciocutaneous flap and the vascularized peroneus longus tendon graft were linked by the perforator and minimal fascial tissue, the skin paddle was able to rotate and slide with comparative ease. The flap survived completely without any complications. The length of follow-up was 12 months and was uneventful. Range of motion of his left wrist joint was slightly limited to 75 degrees. This novel composite flap may be useful for reconstructing long tendon defects associated with extensive forearm soft tissue defects. © 2016 Wiley Periodicals, Inc.
Li, X Q; Wang, X; Han, Y L; Ji, G; Chen, Z H; Zhang, J; Zhu, J P; Duan, J X; He, Y J; Yang, X M; Liu, W J
2018-05-20
Objective: To explore the effects of anteriolateral thigh perforator flap and fascia lata transplantation in combination with computed tomography angiography (CTA) on repair of electrical burn wounds of head with skull exposure and necrosis. Methods: Seven patients with head electrical burns accompanied by skull exposure and necrosis were admitted to our burn center from March 2016 to December 2017. Head CTA was performed before the operation. The diameters of the facial artery and vein or the superficial temporal artery and vein were measured, and their locations were marked on the body surface. Preoperative CTA for flap donor sites in lower extremities were also performed to track the descending branch of the lateral circumflex femoral artery with the similar diameter as the recipient vessels on the head, and their locations were marked on the body surface. Routine wound debridement and skull drilling were performed successively. The size of the wounds after debridement ranged from 12 cm×8 cm to 20 cm×12 cm, and the areas of skull exposure ranged from 8 cm×6 cm to 15 cm×10 cm. Anteriolateral thigh perforator flaps with areas from 13 cm×9 cm to 21 cm×13 cm containing 5-10 cm long vascular pedicles were designed and dissected accordingly. The fascia lata under the flap with area from 5 cm×2 cm to 10 cm×3 cm was dissected according to the length of vascular pedicle. The fascia lata was transplanted to cover the exposed skull, and the anteriolateral thigh perforator flap was transplanted afterwards. The descending branch of the lateral circumflex femoral artery and its accompanying vein of the flap were anastomosed with superficial temporal artery and vein or facial artery and vein before the suture of flap. The flap donor sites were covered by intermediate split-thickness skin graft collected from contralateral thigh or abdomen. Results: The descending branch of the lateral circumflex femoral artery and its accompanying vein were anastomosed with superficial temporal artery and vein in six patients, while those with facial artery and vein in one patient. All the flaps survived after the operation, and no vascular crisis was observed. Wound healing was satisfactory. One patient was lost to follow up. Six patients were followed up for 6 to 10 months. The patients were bald in the head operation area with acceptable appearance. No psychiatric symptom such as headache or epileptic seizure was reported. The flap donor sites were normal in appearance. The muscle strength of the lower extremities all reached grade V. The sensation and movement of the lower extremities were normal. Conclusions: Anterolateral thigh perforator flap with fascia lata transplantation can effectively repair electrical burn wounds of head with skull exposure and necrosis. The fascia lata can be used to protect the vascular pedicle of flaps, which is beneficial to the survival of the flap. Preoperative head and lower extremities CTA can provide reference for intraoperative vascular exploration in donor site and recipient area, so as to shorten operation time.
Dual-dermal-barrier fashion flaps for the treatment of sacral pressure sores.
Hsiao, Yen-Chang; Chuang, Shiow-Shuh
2015-02-01
The sacral region is one of the most vulnerable sites for the development of pressure sores. Even when surgical reconstruction is performed, there is a high chance of recurrence. Therefore, the concept of dual-dermal-barrier fashion flaps for sacral pressure sore reconstruction was proposed. From September 2007 to June 2010, nine patients with grade IV sacral pressures were enrolled. Four patients received bilateral myocutaneous V-Y flaps, four patients received bilateral fasciocutaneous V-Y flaps, and one patient received bilateral rotation-advanced flaps for sacral pressure reconstruction. The flaps were designed based on the perforators of the superior gluteal artery in one patient's reconstructive procedure. All flaps' designs were based on dual-dermal-barrier fashion. The mean follow-up time was 16 months (range = 12-25). No recurrence was noted. Only one patient had a complication of mild dehiscence at the middle suture line, occurring 2 weeks after the reconstructive surgery. The dual-dermal fashion flaps are easily duplicated and versatile. The study has shown minimal morbidity and a reasonable outcome.
Buchel, Edward W; Dalke, Kimberly R; Hayakawa, Thomas Ej
2013-01-01
Abdominal-based autologous free tissue breast reconstruction has undergone significant changes over the past decade. The evolution has focused on limiting morbidity of the donor site. The transition from the transverse rectus abdominus muscle free flap to the muscle-sparing transverse rectus abdominus muscle free flap to the deep inferior epigastric artery perforator free flap has markedly improved abdominal-based autologous breast reconstruction. However, all of these flaps involve an incision through the anterior rectus fascia and potential damage of intercostal motor and sensory nerves. The superficial inferior epigastric artery flap (SIEA) reliably perfuses the ipsilateral hemiabdomen, yet does not violate the fascia or any motor nerves. As a result, the incidence of hernia, abdominal wall weakness and bulging is essentially eliminated. Nevertheless, use of the SIEA flap remains marginal. Vessel size, dissection difficulties and lack of understanding of the relevant anatomy have limited its acceptance. The present article describes a rapid, reliable and safe dissection technique with an algorithm for harvesting the SIEA flap in autologous breast reconstruction.
Aesthetic Penoscrotal Resurfacing: Creating Propeller Flaps from Gluteal Folds.
Han, So-Eun; Kim, Eun-Ji; Sung, Hyun Hwan; Pyon, Jai-Kyong
2018-04-01
Reconstruction of extensive penoscrotal defects is a surgical challenge. Resurfacing defects in highly complex three-dimensional structures and restoring their function are an essential part of the reconstruction of penoscrotal regions. We describe a technique using internal pudendal artery perforator (IPAP) pedicled propeller flaps created from the gluteal fold. This could be a reliable surgical option that maintains a natural looking scrotal pouch with minimal donor site morbidity and optimal sexual activity. We retrospectively reviewed data for 10 consecutive patients who had undergone penoscrotal reconstruction using IPAP pedicled propeller flaps between January 2011 and March 2015. The IPAP was identified using a hand-held Doppler ultrasound device. This was the pivot around which the flap was internally rotated more than 90° in a tension-free manner. The long axis of the flap was centred on the gluteal fold to provide a better-orientated donor site scar. Complications and patient satisfaction with respect to size, colour match, scar appearance, and sexual activity were evaluated. Anatomic and aesthetic penoscrotal reconstruction was performed without any major complications in the follow-up period (mean, 19.7 mo). The mean width of the IPAP pedicled propeller flaps was 6.7cm, and the mean length was 11.7cm. Partial distal flap necrosis occurred in only one case, and healed spontaneously. All of the patients were satisfied with the cosmetic and functional results. On the basis of reliable perforators, donor site morbidity, flap thickness, and a better orientated scar, our technique using IPAP pedicled propeller flaps created from the gluteal fold could be a reasonable surgical option for extensive penoscrotal reconstruction. The creation of pedicled propeller flaps using an internal pudendal artery perforator could be a reliable surgical option for reconstruction of extensive penoscrotal defects. The approach yields functional and aesthetically acceptable surgical results. Copyright © 2016. Published by Elsevier B.V.
Critical assessment of the anterolateral thigh flap donor site.
Townley, W A; Royston, E C; Karmiris, N; Crick, A; Dunn, R L R
2011-12-01
The free anterolateral thigh flap (ALT) is now used as a 'workhorse flap'. The donor site morbidity is thought to be minimal, although most evidence derives from questionnaire-based studies rather than rigorous objective clinical assessment. In particular, robust quantitative data on thigh sensibility and quadriceps function is lacking. The aim of this study was to provide a comprehensive clinical assessment of donor site morbidity. We performed a prospective study of consecutive free ALT perforator flaps performed at Salisbury Foundation Trust between March 2008 and April 2010. The donor site was assessed at six months including a questionnaire (symptoms, function), scar analysis (Vancouver Scar Scale, VSS), and evaluation of quadriceps power and lateral thigh sensibility (compared with the contralateral unoperated thigh). One hundred ALT flaps were performed on 97 patients (mean age 46.8 years). The donor site was closed directly in 88 cases and using a split skin graft in 12 cases. At follow-up (n=68), tingling was the most common reported symptom (59%), whereas pain, itching and muscle herniation were reported infrequently. Donor site scars were mostly flat, pale and soft but widened. Pathological scarring was rare. Sensibility was reduced in donor thighs (p<0.001) and correlated with flap width but peak quadriceps contraction was similar between donor and unoperated thighs. There was a high throughput and diverse application of ALT flap reconstructions during the study period. Reduced sensibility was common around the scar but rarely troublesome. Quadriceps function was not affected even when dissection of intramuscular perforators was required. The ALT is a versatile flap that can deliver a large skin paddle with minimal impact on thigh function. Copyright © 2011 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Magnetic resonance angiography in perforator flap breast reconstruction
Levine, Joshua L.
2016-01-01
Magnetic resonance angiography (MRA) is an extremely useful preoperative imaging test for evaluation of the vasculature of donor tissue to be used in autologous breast reconstruction. MRA has sufficient spacial resolution to reliably visualize 1 mm perforating vessels and to accurately locate vessels in reference to a patient’s anatomic landmarks without exposing patients to ionizing radiation or iodinated contrast. The use of a blood pool contrast agent and the lack of radiation exposure allow multiple studies of multiple anatomic regions in one examination. The following article is a detailed description of our MRA protocol developed with our radiologists with examples that illustrate the utility of MRA in perforator flap breast reconstruction. PMID:27047787
Long-Term Patency of Twisted Vascular Pedicles in Perforator-Based Propeller Flaps.
Jakubietz, Rafael G; Nickel, Aljoscha; Neshkova, Iva; Schmidt, Karsten; Gilbert, Fabian; Meffert, Rainer H; Jakubietz, Michael G
2017-10-01
Propeller flaps require torsion of the vascular pedicle of up to 180 degrees. Contrary to free flaps, where the relevance of an intact vascular pedicle has been documented, little is known regarding twisted pedicles of propeller flaps. As secondary surgeries requiring undermining of the flap are common in the extremities, knowledge regarding the necessity to protect the pedicle is relevant. The aim of this study was a long-term evaluation of the patency of vascular pedicle of propeller flaps. In a retrospective clinical study, 22 patients who underwent soft-tissue reconstruction with a propeller flap were evaluated after 43 months. A Doppler probe was used to locate and evaluate the patency of the vascular pedicle of the flap. The flaps were used in the lower extremity in 19 cases, on the trunk in 3 cases. All flaps had healed. In all patients, an intact vascular pedicle could be found. Flap size, source vessel, or infection could therefore not be linked to an increased risk of pedicle loss. The vascular pedicle of propeller flaps remains patent in the long term. This allows reelevation and undermining of the flap. We therefore recommend protecting the pedicle in all secondary cases to prevent later flap loss.
Bota, Olimpiu; Spindler, Nick; Sauber, Jeannine; Aydogan, Emrah; Langer, Stefan
2017-08-01
Soft-tissue defects caused by radiation injury are a challenging task for the reconstructive surgeon, due to the extent of the soft-tissue damage and the associated injuries of the local blood vessels and bone tissue. We present the application of the versatile deep inferior epigastric perforator (DIEP) flap for the coverage of an extended lateral thigh soft-tissue defect after the surgical resection of an undifferentiated pleomorphic high-grade sarcoma, neoadjuvant chemotherapy, and adjuvant chemo- and radiotherapy. A double-pedicled free DIEP flap (756 cm 2 ) was harvested and anastomosed to the transverse branch of the lateral femoral circumflex artery and a lateral branch of the popliteal artery (P1). The flap survived completely without serious complications, and the patient was able to walk with crutches 3 months postoperatively. This is the first case report of a free bipedicled DIEP flap for the coverage of a thigh defect in a male patient.
Spindler, Nick; Sauber, Jeannine; Aydogan, Emrah; Langer, Stefan
2017-01-01
Summary: Soft-tissue defects caused by radiation injury are a challenging task for the reconstructive surgeon, due to the extent of the soft-tissue damage and the associated injuries of the local blood vessels and bone tissue. We present the application of the versatile deep inferior epigastric perforator (DIEP) flap for the coverage of an extended lateral thigh soft-tissue defect after the surgical resection of an undifferentiated pleomorphic high-grade sarcoma, neoadjuvant chemotherapy, and adjuvant chemo- and radiotherapy. A double-pedicled free DIEP flap (756 cm2) was harvested and anastomosed to the transverse branch of the lateral femoral circumflex artery and a lateral branch of the popliteal artery (P1). The flap survived completely without serious complications, and the patient was able to walk with crutches 3 months postoperatively. This is the first case report of a free bipedicled DIEP flap for the coverage of a thigh defect in a male patient. PMID:28894652
Zhou, Xiao; Xu, Yajun; Rui, Yongjun; Shou, Kuishui; Yao, Qun
2011-02-01
To discuss the effectiveness of distal palm perforator mini-flap in the treatment of scar contracture of digital web-spaces. Between August 2008 and March 2010, 6 cases of scar contracture of digital web-spaces were treated, including 4 males and 2 females and aging 16-68 years (mean, 45 years). The causes were burn injury, twisting injury, and crush injury in 2 cases, respectively. The disease duration was from 3 months to 3 years. The affected digital web-spaces were from index finger to middle finger in 2 cases, from middle finger to ring finger in 3 cases, and from ring finger to small finger in 1 case. The maximum abduction degree of digital web-spaces was 5-10 degrees. The sizes and the depths of reshape of digital web-spaces disappeared. The defect size ranged from 20 mm x 8 mm to 30 mm x 13 mm after opening digital web-spaces. The size of the distal palm perforator mini-flap ranged from 25 mm x 10 mm to 35 mm x 15 mm. The donor sites were sutured directly. All 6 flaps survived and got primary healing. Incisions at donor sites healed by first intention. All patients were followed up 6-12 months. The reconstructed digital web-spaces had good appearance and soft texture. The range of motion of metacarpophalangeal joint was normal. The sizes and the depths of reshape of digital web-spaces were similar to normal ones. The maximum abduction degree of digital web-spaces was 40-60 degrees. There was no scar contracture of incision of palm. The shape of flaps and function of the fingers were satisfactory after 6-12 months of follow-up. It is an ideal method to treat scar contracture of digital web-spaces with distal palm perforator mini-flap.
Frey, Jordan D; Stranix, John T; Chiodo, Michael V; Alperovich, Michael; Ahn, Christina Y; Allen, Robert J; Choi, Mihye; Karp, Nolan S; Levine, Jamie P
2018-05-01
Free flap monitoring in autologous reconstruction after nipple-sparing mastectomy remains controversial. The authors therefore examined outcomes in nipple-sparing mastectomy with buried free flap reconstruction versus free flap reconstruction incorporating a monitoring skin paddle. Autologous free flap reconstructions with nipple-sparing mastectomy performed from 2006 to 2015 were identified. Demographics and operative results were analyzed and compared between buried flaps and those with a skin paddle for monitoring. Two hundred twenty-one free flaps for nipple-sparing mastectomy reconstruction were identified: 50 buried flaps and 171 flaps incorporating a skin paddle. The most common flaps used were deep inferior epigastric perforator (64 percent), profunda artery perforator (12.1 percent), and muscle-sparing transverse rectus abdominis myocutaneous flaps (10.4 percent). Patients undergoing autologous reconstructions with a skin paddle had a significantly greater body mass index (p = 0.006). Mastectomy weight (p = 0.017) and flap weight (p < 0.0001) were significantly greater in flaps incorporating a skin paddle. Comparing outcomes, there were no significant differences in flap failure (2.0 percent versus 2.3 percent; p = 1.000) or percentage of flaps requiring return to the operating room (6.0 percent versus 4.7 percent; p = 0.715) between groups. Buried flaps had an absolute greater mean number of revision procedures per nipple-sparing mastectomy (0.82) compared with the skin paddle group (0.44); however, rates of revision procedures per nipple-sparing mastectomy were statistically equivalent between the groups (p = 0.296). Although buried free flap reconstruction in nipple-sparing mastectomy has been shown to be safe and effective, the authors' technique has evolved to favor incorporating a skin paddle, which allows for clinical monitoring and can be removed at the time of secondary revision. Therapeutic, III.
A systematic review of functional donor-site morbidity after latissimus dorsi muscle transfer.
Lee, Kyeong-Tae; Mun, Goo-Hyun
2014-08-01
The authors performed a comprehensive literature review regarding functional impairment after latissimus dorsi muscle transfer, to investigate functional changes in the donor site and the potential impact on patients' daily lives. The PubMed database was searched for articles regarding functional donor-site morbidity following latissimus dorsi muscle flap harvest. Articles discussing the thoracodorsal artery perforator flap, which shares the same donor sites with the latissimus dorsi muscle flap, were also included. Functional morbidity was analyzed based on questionnaire of subjective symptoms, Disabilities of the Arm, Shoulder and Hand questionnaire, shoulder range of motion, and shoulder strength. Twenty-two articles representing 719 cases in 644 patients were reviewed, including seven prospective and 15 retrospective cohort studies. As a questionnaire summary from eight articles, 94 of 232 patients (41 percent) experienced any kind of discomfort at the donor site. In the Disabilities of the Arm, Shoulder and Hand questionnaire from seven articles, little difficulty in daily activities but significant difficulties in sports and art activities were observed. Nine of 13 articles reported some limitations of shoulder motion, particularly during the early postoperative period, and four other articles detected little limitation. Eight of 12 articles reported some shoulder strength weakness over time, and shoulder extension, adduction, and internal rotation were commonly involved. The muscle-sparing latissimus dorsi and thoracodorsal artery perforator flaps showed low functional morbidity. Functional impairment of the shoulder could develop after latissimus dorsi muscle flap transfer. Knowledge of the flap's functional morbidity will allow surgeons to inform patients regarding donor-site expectations and to accomplish better surgical outcomes.
Kang, Stephen Y; Spector, Matthew E; Chepeha, Douglas B
2017-11-01
To demonstrate three reconstructive advantages of the perforator based rectus free tissue transfer: long pedicle, customizable adipose tissue, and volume reconstruction without muscle atrophy within a contained space. Thirty patients with defects of the head and neck were reconstructed with the perforator based rectus free tissue transfer. Transplant success was 93%. Mean pedicle length was 13.4cm. Eleven patients (37%) had vessel-poor necks and the long pedicle provided by this transplant avoided the need for vein grafts in these patients. Adipose tissue was molded in 17 patients (57%). Twenty-five patients (83%) had defects within a contained space, such as the orbit, where it was critical to have a transplant that avoided muscle atrophy. The perforator based rectus free tissue transfer provides a long pedicle, moldable fat for flap customization, and is useful in reconstruction of defects within a contained space where volume loss due to muscle atrophy is prevented. Copyright © 2017 Elsevier Ltd. All rights reserved.
Latissimus Dorsi Flap in Breast Reconstruction
Sood, Rachita; Easow, Jeena M.; Konopka, Geoffrey; Panthaki, Zubin J.
2018-01-01
Background: Surgeons employ the latissimus dorsi flap (LDF) for reconstruction of a large variety of breast cancer surgery defects, including quadrantectomy, lumpectomy, modified radical mastectomy, and others. The LDF may be used in delayed or immediate reconstruction, in combination with tissue expanders for a staged reconstruction, with implant-based immediate reconstruction, or alone as an autogenous flap. Methods: The authors discuss the historical uses and more recent developments in the LDF. More recent advancements, including the “scarless” approach and augmentation with the thoracodorsal artery perforator flap, are discussed. Results: The LDF is a reliable means for soft tissue coverage providing form and function during breast reconstruction with acceptable perioperative and long-term morbidities. Conclusions: When there is a paucity of tissue, the LDF can provide tissue volume in autologous reconstruction, as well as a reliable vascular pedicle for implant-based reconstruction as in the setting of irradiated tissue. PMID:29334788
Visualization of Skin Perfusion by Indocyanine Green Fluorescence Angiography—A Feasibility Study
Steinbacher, Johannes; Yoshimatsu, Hidehiko; Meng, Stefan; Hamscha, Ulrike M.; Chan, Chun-Sheng; Weninger, Wolfgang J.; Wu, Chieh-Tsai; Cheng, Ming-Huei
2017-01-01
Summary: Plastic and reconstructive surgery relies on the knowledge of angiosomes in the raising of microsurgical flaps. Growing interest in muscle-sparing perforator flaps calls for reliable methods to assess the clinical feasibility of new donor sites in anatomical studies. Several injection techniques are known for the evaluation of vascular territories. Indocyanine green–based fluorescence angiography has found wide application in the clinical assessment of tissue perfusion. In this article, the use of indocyanine green–based fluorescence angiography for the assessment of perforasomes in anatomical studies is described for the first time. PMID:29062637
Kim, Jeong Tae; Ho, Samuel Y M; Kim, Youn Hwan
2014-02-01
Postoperative flap monitoring is a vital aspect of free tissue transfer in order to detect early vascular compromise and to enable early flap salvage. The implantable Doppler monitoring system is one of many monitoring devices used to ensure accuracy and reduce unnecessary flap explorations. However, there are a number of concerns with its use, namely tension on the anastomosis, possible vessel constriction and false-negative detection. This study aimed to alleviate these concerns, by introducing a new method of placing the implantable Doppler probe on the adjacent vessel limb of a chimaeric flap. This is illustrated by a case series of chimaeric free tissue flaps that allow this surrogate placement of the Doppler probe. The flap is raised in a chimaeric fashion, with a main perforator pedicle to the skin or muscle paddle for the main reconstructive purpose and a side branch from the main pedicle going to a smaller adipofascial or muscle flap for monitoring. This branch vascular pedicle leading to the chimaeric tissue is kept sufficiently long to enable placement of the Doppler cuff and prevent turbulence. The probe of a Cook-Swartz implantable Doppler system is placed around the branch pedicle, approximately 5 mm from the branching point, and secured with a vessel clip. This is then secured away from the major vessels of the main free flap. Removal of the probe's crystal and wire is easily done with a single gentle traction on postoperative day 7. Five cases of chimaeric free flaps were performed with this manoeuvre: three thoracodorsal perforator chimaeric flaps for head-and-neck or extremity reconstruction, one latissimus dorsi neuromuscular chimaeric flap for facial reanimation and one digastric lymph node transfer for the treatment of lower limb lymphoedema. The Doppler system showed a low but sustained oscillating flow in all cases indicating vascular patency, with minimal flow interference from other large-calibre vessels. There was no discernible kinking on the anastomosis. There were no complications encountered during probe removal. This postoperative monitoring manoeuvre was done successfully with good results. The monitoring equipment is very sensitive to any flow disturbance due to positional changes in the head-and-neck region or the extremities and is able to detect flow changes in buried flaps postoperatively. Chimaeric flap composition is easier now than before because of perforator-oriented pedicle dissection, and surrogate Doppler monitoring is one more application of the chimaeric flap. This novel chimaeric fashion of implantable Doppler probe placement is a good surrogate measure of flow in the main pedicle. Copyright © 2013. Published by Elsevier Ltd.
[Free vascularized popliteal artery cutaneous branch flap for repair of wound on foot and ankle].
Shen, Lilin; Song, Suping; Lin, Cuixia; Li, Wenlong; Sun, Xuesheng; Zhu, Tao; Li, Qiang
2014-01-01
To investigate the feasibility and effectiveness of free popi iteal artery cutaneous branch flap anastomosed with lateral tarsal artery and vein for the repair of wound on the foot and ankle by anatomical observation and clinical application. Latex was poured into the blood vessels of 8 cadavers, then perforator vessel of posterolateral upper calf was dissected, and the popl iteal artery cutaneous branch flap was designed with a pedicle of 2.5 cm in length; the lateral tarsal artery of the foot was dissected, could be freed to 6 cm in length; the diameter of these vessels was measured, and the number of the accompanying veins was counted. Between March 2010 and January 2013, 13 cases of foot and ankle wounds were repaired with popliteal artery cutaneous branch flap anastomosed with lateral tarsal artery and vein. The size of flaps ranged from 6.0 cm x 4.0 cm to 7.5 cm x 5.5 cm. There were 11 males and 2 females, aged from 41 to 65 years (mean, 47.3 years). The causes of injury included traffic accident in 8 cases, crushing in 4 cases, and twist by machine in 1 case. The size of wounds, ranged from 5.0 cm x 3.5 cm to 7.0 cm x 5.0 cm. The donor sites were sutured directly. According to anatomical observation, the popliteal artery cutaneous branch flap was designed by using the lateral popliteal artery perforator for shaft. The vessel of the pedicle perforator flaps from the popliteal artery cutaneous branch flap matched well with the lateral tarsal artery. vascular crisis occurred in 2 flaps, which survived after symptomatic treatment; the other flaps survived, with primary healing of wound and incision at donor site. The patients were all followed up 5-18 months (mean, 11 months). The flap had normal color and good elasticity. Second stage operation was performed to make the flap thinner in 3 female patients because of bulky flaps. The remaining patients had no obvious fat flap. According to American Orthopaedic Foot and Ankle Society (AOFAS) score for evaluation of the ankle function at 6 months after operation, the results were excellent in 7 cases, good in 5 cases, and fair in 1 case, with an excellent and good rate of 92.3%. Free popliteal artery cutaneous branch flap anastomosed with lateral tarsal artery and vein for the repair of wound on the foot and ankle is simple and effective. The donor site is hidden.
Dražan, L; Lombardo, G A G
The preoperative perforator mapping is an important step in autologous breast reconstruction, making the flap raising safer, more predictable and time-saving. Although the Doppler exam has proven to be less accurate in locating perforators compared with colour duplex sonography and CTA, it will probably remain of importance in clinical practice. The aim of this paper is to share some advices on how to perform a Doppler exam in preoperative evaluation of a DIEAp flap, increasing its reliability in location of the perforators. The study was carried-out preoperatively on 26 consecutive patients. For the evaluation of the matching between Doppler Dot and operative finding was used a Cartesian coordinate systemResults: We have marked preoperatively 145 perforators in 26 patients for a total of 52 semi-abdomens. An average of 5.6 vessels per patient were marked. Of these, 80 (55.17%) were found between 0-1 cm, 36 (24.82%) between 1-2 cm and 5 (3.4%) of these more than 2 cm from each other. We had 24 (16.55%) false positives in which there was no correspondence between the signal and the intraoperative finding. Although the Doppler exam may not provide the same anatomic details as the other newer modalities, such as CTA and MRA, the HHD remains a very useful and important tool for autologous reconstruction. We recommend performing this exam in our standardized and reproducible method to improve the reliability..
Du, Yi-fei; Zhou, Wei-na; Li, Jie; Jiang, Hong-bing; Yuan, Hua; Wan, Lin-zhong
2014-11-01
The aim of this study was to investigate the reliability and outcomes of a new design of facial artery perforator flaps, extending from the angle of the mouth to the border of the mandible, for the reconstruction of small- to medium-sized intraoral defects. The technique had been used in 23 patients between February 2009 and August 2012. The locations of intraoral defects included the tongue, the floor of the mouth, the inferior gingival mucosa, and the sublingual gland. All flaps were monitored for complications including skin loss and ischemia. The functions of appearance, swallowing, and speech were assessed 6 months after operation with the University of Washington Quality of Life Questionnaire. All flaps presented with satisfactory results except for one, which demonstrated superficial tip necrosis that settled after conservative treatment. The follow-up period ranged from 6 to 12 months, and 1 patient died as a result of pulmonary metastasis, and 3 patients underwent second surgery because of local tumor recurrence (2patients) and cervical recurrence (1 patient). Nineteen patients were assessed with the University of Washington Quality of Life Questionnaire, and the mean (SD) scores of appearance, swallowing, and speech were 57.89 (14.45), 83.68 (19.98), and 81.58 (23.16), respectively. This design of facial artery perforator flaps could provide an efficient and cost-effective method for reconstruction of small- to medium-sized intraoral defects with a low surgical morbidity and satisfactory levels of quality of life.
Santanelli Di Pompeo, Fabio; Longo, Benedetto; Pagnoni, Marco; Laporta, Rosaria
2015-05-01
Recidivating pressure sores are a frequent complication in meningomyelocele patients because of their limitation in motility and their scarce ability to monitor the pressure applied on insensate areas while seated. We report the utilization of the sensate pedicled anterolateral thigh perforator flap for reconstruction of ischiatic sores in meningomyelocele patients. Between May 2011 and September 2013, five patients underwent transfer of a sensate pedicled anterolateral thigh flap, by an intermuscular passageway through the upper thigh, to reach the ischial defect. Flap was properly harvested from the thigh after assessment of the lateral cutaneous femoral nerve sensitive area with the Pressure-Specified Sensory Device. In all cases the flap reached the ischial defect harmlessly, healing was uneventful with no immediate nor late complications. Each patient showed persistence of sensitivity at the reconstructed area and no recurrent ischiatic sore was observed at mean follow-up of 26.4 months. The sensate pedicled anterolateral thigh flap is a valuable solution for coverage of recurrent ischial sores in meningomyelocele patients, in which pressure consciousness is fundamental. The intermuscular passageway allows to reduce the distance between flap's vascular pedicle origin and the ischial defect, hence to use the more reliable skin from the middle third of the anterolateral thigh. © 2014 Wiley Periodicals, Inc.
Suprascarpal fat pad thickness may predict venous drainage patterns in abdominal wall flaps.
Bast, John; Pitcher, Austin A; Small, Kevin; Otterburn, David M
2016-02-01
Abdominal wall flaps are routinely used in reconstructive procedures. In some patients inadequate venous drainage from the deep vein may cause fat necrosis or flap failure. Occasionally the superficial inferior epigastric vessels (SIEV) are of sufficient size to allow for microvascular revascularization. This study looked at the ratio of the sub- and suprascarpal fat layers, the number of deep system perforators, and SIEV diameter to determine any correlation of the fat topography and SIEV. 50 abdominal/pelvic CT angiograms (100 hemiabdomens) were examined in women aged 34-70 years for number of perforators, SIEV diameter, and fat pad thickness above and below Scarpa's fascia. Data was analyzed using multivariate model. The average suprascarpal and subscarpal layers were 18.6 ± 11.5 mm and 6.2 ± 7.2 mm thick, respectively. The average SIEV diameter was 2.06 ± 0.81 mm and the average number of perforators was 2.09 ± 1.03 per hemiabdomen. Hemiabdomens with suprascarpal thickness>23 mm had greater SIEV diameter [2.69 mm vs. 1.8 mm (P < 0.0001)] The fat layer thickness did not correlate with the number of perforators. Neither subscarpal fat thickness nor suprascarpal-to-subscarpal fat layer thickness correlated significantly with SIEV caliber or number of perforators in multivariate model. Suprascarpal fat pad thicker than 23 mm had larger SIEVs irrespective of the number of deep system perforators. This may indicate a cohort of patients at risk of venous congestion from poor venous drainage if only the deep system is revascularized. We recommend harvesting the SIEV in patients with suprascarpal fat pad >23 mm to aid in superficial drainage. © 2015 Wiley Periodicals, Inc.
Chen, Wei-Liang; Zhang, Da-ming; Yang, Zhao-hui; Huang, Zhi-quan; Wang, Jian-guang; Zhang, Bin; Li, Jing-song
2010-10-01
This clinical study assessed a pedicled supraclavicular fasciocutaneous island flap (SFIF) based on the transverse cervical artery that was extended to include shoulder skin for reconstructing the head and neck. Pedicled SFIFs extended to include the shoulder skin based on the cutaneous feeder vessels and perforator vessels in the deep fascia of the transverse cervical artery were designed for 24 patients with defects of the head and neck after cancer ablation. Preoperative 3-dimensional computed tomographic angiography was performed in all patients. The patients consisted of 15 men and 9 women ranging in age from 24 to 73 years. The primary lesions included squamous cell carcinoma of the tongue, buccal mucosa, floor of the mouth, oropharynx, palate, and lower gingiva. Three-dimensional computed tomographic angiography showed that the transverse cervical artery arose from the thyrocervical trunk in 13 cases and from the subclavian artery in 11 cases. The diameter of the artery ranged from 0.15 to 0.24 cm. The size of flaps ranged from 4 × 8 cm to 6 × 12 cm, and the mean length of the vascular pedicle was approximately 18.5 cm. Of the flaps, 23 survived completely, for a success rate of 95.8%. Three patients underwent radiotherapy, and the follow-up period ranged from 3 to 12 months. One patient died of local tumor recurrence, and cervical recurrences developed in 3 patients. An SFIF extended to include the shoulder skin based on the cutaneous feeder vessels and perforator vessels in the deep fascia of the transverse cervical artery is a useful, viable option for defects of the head and neck after cancer ablation. Copyright © 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Yang, Lin; Liu, Hongjun; Zhang, Wenzhong; Song, Guoxun; Xia, Shicong; Zhang, Naichen; Gu, Jiaxiang; Yuan, Chaoqun
2017-10-01
To explore the effectiveness of modified anterolateral thigh perforator flap pedicled by cross-bridge microvascular anastomosis in treatment of soft tissue defects in the middle and lower segments of the leg. Between March 2011 and June 2015, 15 cases with skin and soft tissue defects in the middle and lower segments of the legs were treated. There were 9 males and 6 females, aged 22-48 years (mean, 32.6 years). Of whom, 8 patients caused by traffic accidents, 5 by machine twist, and 2 by crash injury of heavy object. The mean interval from injury to admission was 82.6 hours (range, 2 hours to 1 week). The area of defect ranged from 13 cm×9 cm to 23 cm×16 cm. After primary debridement and vaccum sealing drainage treatment, the defects were repaired with modified anterolateral thigh perforator flap pedicled by cross-bridge microvascular anastomosis. The size of flap ranged from 15 cm×10 cm to 25 cm×15 cm. The donor sites were sutured directly or repaired with the skin grafts. The pedicle division was done at 4 weeks after operation. After operation, venous crisis occurred in 1 case and distal skin necrosis in 2 cases which was healed by dressing change. The other tissue flaps survived successfully and wounds healed by first intention. All skin grafts at donor site survived after operation, and primary healing of wound was obtained. All patients were followed up 6-24 months (mean, 13 months). All flaps were characterized by soft texture, satisfactory appearance, and restoring the protective sensation. Moreover, the two-point discrimination ranged from 15 to 28 mm (mean, 19.5 mm) at 6 months after operation. The function of both lower extremities were normal without obvious contracture of scar at donor site. Modified free anterolateral thigh perforator flap, with little damage in donor site, a reliable blood supply by making a cross-bridge microvascular anastomosis with pretibial or posterior tibial blood vessel on normal leg, is a reliable alternative method for repairing soft tissue defects with the main vessels of serious injury in the middle and lower segments of the leg.
Artiaco, Stefano; Bianchi, Pasquale; Boux, Elena; Tos, Pierluigi
2014-01-01
The reconstruction of loss of substance due to trauma or oncological excision may have relevant functional and aesthetic implications. We report our experience in twenty-one cases of propeller flaps for the treatment of loss of substance of the upper and lower limbs. The etiology of defect was tumor excision in nine cases, trauma in seven cases, surgical wound complications in four cases, and chronic osteomyelitis in one case. Clinical results were favorable in most cases and eighteen flaps survived. We observed an overall complication rate of 33% with four cases of superficial epidermolysis that spontaneously healed and three cases of partial flap loss ranging from 10 to 50% that required surgical revision by means of skin graft (two cases) or ALT free flap (one case). Propeller flap harvesting requires great care and experience, and potential complications may occur even in expert hands. When indicated by the characteristic of the defect, these flaps can be a useful surgical option for the treatment of loss of substance of upper and lower limbs. PMID:25250327
Colohan, Shannon; Wong, Corrine; Lakhiani, Chrisovalantis; Cheng, Angela; Maia, Munique; Arbique, Gary; Saint-Cyr, Michel
2012-12-01
Increasing focus on reducing morbidity from latissimus dorsi flaps has led to the evolution of muscle-sparing variants and perforator-based flaps. This study aimed to investigate the vascular anatomy of the muscle-sparing variant and to describe its application as a free flap based on the descending branch of the thoracodorsal artery. Twelve fresh cadavers underwent anatomical dissection and angiographic injection studies of the thoracodorsal arterial system. The musculocutaneous territories of the descending and transverse branches to the latissimus dorsi muscle were identified and assessed using three-dimensional reconstruction software of computed tomography imaging results. In the clinical study, five patients underwent reconstruction of a variety of defects using the free descending branch muscle-sparing latissimus dorsi flap. Three- and four-dimensional (computed tomography) angiography demonstrated perfusion of the latissimus dorsi muscle by the transverse and descending branches, with overlap of vascular territories via cross-linking vessels. The descending branch supplied a slightly greater cutaneous area overlying the muscle, although differences between both branches were not significant (p = 0.76). In the clinical study, the free muscle-sparing latissimus dorsi flap provided excellent coverage with no flap complications or seroma. The free muscle-sparing latissimus dorsi flap based on the descending branch of the thoracodorsal artery is a viable reconstructive option. Significant collateral flow between vessels allows for larger flap harvest than would be expected. The flap is technically simple to harvest, provides a large perfusion area, and is a reliable variant of the full latissimus dorsi flap. Therapeutic, V.
Wei, Fu-Chan; Mardini, Samir
2004-09-15
Free-tissue transfer has become the accepted standard for reconstruction of complex defects. With the growth of this field, anatomic studies and clinical work have added many flaps to the armamentarium of the microvascular surgeon. Further advancements and experience with techniques of perforator flap surgery have allowed for the harvest of flaps in a free-style manner, where a flap is harvested based only on the preoperative knowledge of Doppler signals present in a specific region. Between June of 2002 and September of 2003, 13 free-style free flaps were harvested from the region of the thigh. All patients presented with an oral or pharyngeal cancer and underwent resection and immediate reconstruction of these flaps. All flaps were cutaneous and were harvested in a suprafascial plane. The average size of the flaps was 108 cm2 (range, 36 to 187 cm2), and the average length of the vascular pedicle was 10 cm (range, 9 to 12 cm). All flaps were successful in achieving wound coverage and functional outcomes without any vascular compromise necessitating re-exploration. Free-style free flaps have become a clinical reality. The concepts and techniques used to harvest a free-style free flap will aid in dealing with anatomic variations that are encountered during conventional flap harvest. Future trends in flap selection will focus mainly on choosing tissue with appropriate texture, thickness, and pliability to match requirements at the recipient site while minimizing donor-site morbidity.
Mohan, Anita T; Rammos, Charalambos K; Akhavan, Arya A; Martinez, Jorys; Wu, Peter S; Moran, Steven L; Sim, Franklin H; Behan, Felix; Mardini, Samir; Saint-Cyr, Michel
2016-06-01
Keystone flaps have demonstrated growing clinical applications in reconstructive surgery in the past decade. This article highlights flap modifications and their versatility for clinical applications and management of complex defects. A retrospective chart review was conducted of consecutive patients undergoing keystone flap reconstruction at the authors' institution from January of 2012 to December of 2014. Patient demographics, indications, and operative and postoperative details were abstracted. Forty-two keystone flaps were performed in 36 patients. Indications included malignant melanoma (n = 14), soft-tissue sarcoma (n = 12), benign pathologic conditions (e.g., exposed hardware, enterocutaneous fistula, tissue necrosis) (n = 6), and nonmelanoma skin cancer (n = 4). Twenty-eight percent received neoadjuvant irradiation, and 70 percent of these were for sarcoma. Locoregional adjunct flaps were performed in eight patients. The deep fascia was nearly completely in a circumferential manner in 18 of 36 patients (50 percent), in 92 percent of the sarcoma reconstructions, and located mainly in the lower extremity. Average defect size was 215 cm (range, 4 to 1000 cm). Average defect size was 474 cm and 35.8 cm after sarcoma and malignant melanoma resection, respectively. Average flap size was 344 cm (range, 5 to 1350 cm). Ninety percent of cases had flap sizes exceeding the traditional 1:1 ratio. There was no flap loss or partial necrosis. Mean time to mobilization was 1.8 days, and mean hospital length of stay was 6.8 days. Keystone flaps offer an excellent versatile tool for reconstructive surgeons. Fundamental principles behind the vascular basis of the keystone flap and its modifications permit their greater utility in complex wounds in the settings of large oncologic resections, irradiation, and trauma. Therapeutic, IV.
Boucher, F; Pinatel, B; Shipkov, H; Mertens, P; Rouviere, O; Braye, F; Mojallal, A
2014-10-01
The latissimus dorsi muscle flap is a type V according to Mathes and Nahai. It is vascularized by a proximal main pedicle represented by the thoraco-dorsal pedicle and pedicle distal accessory represented by the dorsal branches of the posterior intercostal arteries. The main thoraco-dorsal pedicle has a descending branch and a transverse branch. This anatomical study clarifies the muscular territory vascularized by the transverse branch of thoraco-dorsal artery for a secondary use after harvesting a thoraco-dorsal artery perforator flap or a muscle-sparing latissimus dorsi flap. Our study focused on ten dissections latissimus dorsi muscle taken from five fresh cadavers chest, carried out within the University Department of Anatomy. The descending branch of thoraco-dorsal artery was ligated, the transverse branch was cannulated and injected with a mixture of barium sulfate/gelatin. After freezing, a static angiotomodensitometry (3D) of each flap was performed. The average muscular surface vascularized by the transverse branch is measured at 80% (77% minimum value, maximum value 83%) of the complete latissimus dorsi muscle. Intermuscular connections between the two branches of thoraco-dorsal pedicle were shown. The use of a ipsilateral latissimus dorsi muscle is a therapeutic option after harvesting a thoraco-dorsal artery perforator flap (TAP) or a muscle-sparing latissimus dorsi flap (MSLD-flap). Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Kansal, Sandeep; Goil, Pradeep; Agarwal, Vijay; Agarwal, Swarnima; Mishra, Shashank; Agarwal, Deepak; Singh, Pranay
2014-01-01
Paucity of soft tissue available locally for reconstruction of defects in leg and foot presents a challenge for reconstructive surgeon. The use of reverse pedicle-based greater saphenous neuro-veno-fasciocutaneous flap in reconstruction of lower leg and foot presents a viable alternative to free flap and cross-leg flap reconstruction. The vascular axis of the flap is formed by the vessels accompanying the saphenous nerve and the greater saphenous vein. We present here our experience with reverse saphenous neurocutaneous flap which provides a stable cover without the need to sacrifice any important vessel of leg. The study is conducted from March 2003 through Dec 2009 and included a total of 96 patients with defects in lower two-thirds of leg and foot. There are 74 males and 22 females. Distal pivot point was kept approximately 5-6 cm from tip of medial malleolus, thus preserving the distal most perforator, and the flap is turned and inserted into the defect. Donor site is covered with a split thickness skin graft. Postoperative follow-up period was 6 weeks to 6 months. The procedure is uneventful in 77 cases. Infection is observed in 14 cases. Partial flap necrosis occurs in 2 cases. Total flap necrosis is noted in 3 cases. Reverse pedicle saphenous flap can be used to reconstruct defects of lower one-third leg and foot with a reliable blood supply with a large arc of rotation while having minimal donor site morbidity.
Teoh, Raymond; Johnson, Raleigh F; Nishino, Thomas K; Ethridge, Richard T
2007-01-01
The deep inferior epigastric perforator flap procedure has become a popular alternative for women who require breast reconstruction. One of the difficulties with this procedure is identifying perforator arteries large enough to ensure that the harvested tissue is well vascularized. Current techniques involve imaging the perforator arteries with computed tomography (CT) to produce a grid mapping the locations of the perforator arteries relative to the umbilicus. To compare the time it takes to produce a map of the perforators using either two-dimensional (2D) or three-dimensional (3D) CT, and to see whether there is a benefit in using a 3D model. Patient CT abdomen and pelvis scans were acquired from a GE 64-slice scanner. CT image processing was performed with the GE 3D Advantage Workstation v4.2 software. Maps of the perforators were generated both as 2D and 3D representations. Perforators within a region 5 cm rostral and 7 cm caudal to the umbilicus were measured and the times to perform these measurements using both 2D and 3D images were recorded by a stopwatch. Although the 3D method took longer than the 2D method (mean [+/- SD] time 1:51+/-0:35 min versus 1:08+/-0:16 min per perforator artery, respectively), producing a 3D image provides much more information than the 2D images alone. Additionally, an actual-sized 3D image can be printed out, removing the need to make measurements and producing a grid. Although it took less time to create a grid of the perforators using 2D axial CT scans, the 3D reconstruction of the abdomen allows the plastic surgeons to better visualize the patient's anatomy and has definite clinical utility.
Nanidis, Theodore G; Ridha, Hyder; Jallali, Navid
2014-10-01
Estimation of the volume of abdominal tissue is desirable when planning autologous abdominal based breast reconstruction. However, this can be difficult clinically. The aim of this study was to develop a simple, yet reliable method of calculating the deep inferior epigastric artery perforator flap weight using the routine preoperative computed tomography angiogram (CTA) scan. Our mathematical formula is based on the shape of a DIEP flap resembling that of an isosceles triangular prism. Thus its volume can be calculated with a standard mathematical formula. Using bony landmarks three measurements were acquired from the CTA scan to calculate the flap weight. This was then compared to the actual flap weight harvested in both a retrospective feasibility and prospective study. In the retrospective group 17 DIEP flaps in 17 patients were analyzed. Average predicted flap weight was 667 g (range 293-1254). The average actual flap weight was 657 g (range 300-1290) giving an average percentage error of 6.8% (p-value for weight difference 0.53). In the prospective group 15 DIEP flaps in 15 patients were analyzed. Average predicted flap weight was 618 g (range 320-925). The average actual flap weight was 624 g (range 356-970) giving an average percentage error of 6.38% (p-value for weight difference 0.57). This formula is a quick, reliable and accurate way of estimating the volume of abdominal tissue using the preoperative CTA scan. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Yamamoto, Katsumi; Michida, Tomoki; Nishida, Tsutomu; Hayashi, Shiro; Naito, Masafumi; Ito, Toshifumi
2015-01-01
Endoscopic submucosal dissection (ESD) is very useful in en bloc resection of large superficial colorectal tumors but is a technically difficult procedure because the colonic wall is thin and endoscopic maneuverability is poor because of colonic flexure and extensibility. A high risk of perforation has been reported in colorectal ESD. To prevent complications such as perforation and unexpected bleeding, it is crucial to ensure good visualization of the submucosal layer by creating a mucosal flap, which is an exfoliated mucosa for inserting the tip of the endoscope under it. The creation of a mucosal flap is often technically difficult; however, various types of equipment, appropriate strategy, and novel procedures including our clip-flap method, appear to facilitate mucosal flap creation, improving the safety and success rate of ESD. Favorable treatment outcomes with colorectal ESD have already been reported in many advanced institutions, and appropriate understanding of techniques and development of training systems are required for world-wide standardization of colorectal ESD. Here, we describe recent technical advances for safe and successful colorectal ESD. PMID:26468335
Iida, Takuya; Yoshimatsu, Hidehiko; Yamamoto, Takumi; Koshima, Isao
2016-12-01
In head and neck reconstruction using free flaps, microvascular anastomosis is commonly performed in an end-to-end fashion to relatively sizable arteries including the superficial temporal, facial, and superior thyroid arteries. With the recent developments of less invasive perforator flaps such as the superficial circumflex iliac artery perforator flap, anastomosis of smaller vessels of less than 0.8 mm diameter has become necessary; however, appropriate recipient arteries for end-to-end anastomosis are often absent. We have introduced supermicrosurgical end-to-side anastomosis to such arteries in 12 cases of head and neck reconstruction. Double-needle, short-thread microsutures were used to facilitate this procedure, and indocyanine green intraoperative angiography was used to confirm patency. All patients, except one with partial necrosis, survived. We believe that our method is a safe and reliable option for cases in which there is a discrepancy between the flap pedicle and recipient arteries. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Distally Based Sural Artery Peroneus Flap (DBSPF) for Foot and Ankle Reconstruction
Ebrahiem, Ahmed Ali; Manas, Raj Kumar
2017-01-01
Background: Reconstruction of soft-tissue defects in lower third of leg, ankle, and foot has been a challenge and reconstructive surgeons have been trying to innovate different flaps. To solve this issue, we propose a distally based sural artery peroneus flap (DBSPF) in which we include superficial portion of the peroneus brevis muscle and its blood supply with the peroneal artery distally. The aim of this study was to evaluate the functional outcome and its usefulness over conventional distal sural artery flap or other local options available. Methods: This is a case series of 20 patients that include a DBSPF that was done for defects around ankle, distal leg, and foot caused by trauma or tumor ablation within the period of June 2013 to March 2015 in Kasralainy Hospital, Cairo. All cases were evaluated according to flap vascularity, distal reach of flap, aesthetic outcome, and donor-site morbidity. Results: All flaps survived. One flap developed venous congestion that subsided spontaneously with limb elevation. The flap dimension ranged from 42 cm to 442 cm2, and it reached the midfoot easily. The pivot point was kept as low as 2–6 cm from lateral malleolus according to location of perforators. The ankle stability was maintained, and the desired aesthetic outcome was achieved. Conclusions: The DBSPF is an addition to the armamentarium in plastic surgery for defects around ankle, distal leg, and foot. It is an easy and swift procedure as compared with complex microsurgical reconstruction. PMID:28507850
Cherubino, Mario; Turri-Zanoni, Mario; Battaglia, Paolo; Giudice, Marco; Pellegatta, Igor; Tamborini, Federico; Maggiulli, Francesca; Guzzetti, Luca; Di Giovanna, Danilo; Bignami, Maurizio; Calati, Carolina; Castelnuovo, Paolo; Valdatta, Luigi
2017-01-01
Complex cranio-orbito-facial defects after skull base cancers resection entail a functional and esthetic reconstruction. The introduction of endoscopic assisted techniques for excision surgery with the advances in reconstructive surgery and anesthesiology allowed to improve the management of such critical patients. We report a series of chimeric anterolateral thigh (ALT) flaps used to reconstruct complex cranio-orbital-facial defects after skull base surgery. A retrospective review of patients that underwent cranio-orbito-facial reconstruction using a chimeric ALT flap from March 2013 to October 2015 at a single tertiary care referral Institute was performed. All patients were affected by locally-advanced malignant tumor and the resulting defects involved the skull base in all cases. The ALT flaps were perforator-based flaps with different components: fascia, skin and muscle. The different flap territories had independent vascular supply and were independent of any physical interconnection except where linked by a common source vessel. Ten patients were included in the study. Three patients underwent adjuvant radiotherapy and to chemotherapy. The mean hospitalization time was 21 days (range, 8-24 days). One failure was observed. After a mean follow-up of 12.4 months, 3 patients died of the disease, 2 are alive with disease, while 5 patients (50%) are currently alive without evidence of disease. Chimeric ALT flap is a reliable and versatile reconstructive option for complex cranio-orbito-facial defects resulting from skull base surgery. The chimeric flap composed of different territories proved to be adequate for a patient-tailored three-dimensional reconstruction of the defects as well as able to resist to the postoperative adjuvant treatments. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Funding analysis of bilateral autologous free-flap breast reconstructions in Australia.
Sinha, Shiba; Ruskin, Olivia; McCombe, David; Morrison, Wayne; Webb, Angela
2015-08-01
Bilateral breast reconstructions are being increasingly performed. Autologous free-flap reconstructions represent the gold standard for post-mastectomy breast reconstruction but are resource intensive. This study aims to investigate the difference between hospital reimbursement and true cost of bilateral autologous free-flap reconstructions. Retrospective analysis of patients who underwent bilateral autologous free-flap reconstructions at a single Australian tertiary referral centre was performed. Hospital reimbursement was determined from coding analysis. A true cost analysis was also performed. Comparisons were made considering the effect of timing, indication and complications of the procedure. Forty-six bilateral autologous free-flap procedures were performed (87 deep inferior epigastric perforators (DIEPs), four superficial inferior epigastric artery perforator flaps (SIEAs) and one muscle-sparing free transverse rectus abdominis myocutaneous flap (MS-TRAM)). The mean funding discrepancy between hospital reimbursement and actual cost was $12,137 ± $8539 (mean ± standard deviation (SD)) (n = 46). Twenty-four per cent (n = 11) of the cases had been coded inaccurately. If these cases were excluded from analysis, the mean funding discrepancy per case was $9168 ± $7453 (n = 35). Minor and major complications significantly increased the true cost and funding discrepancy (p = 0.02). Bilateral free-flap breast reconstructions performed in Australian public hospitals result in a funding discrepancy. Failure to be economically viable threatens the provision of this procedure in the public system. Plastic surgeons and hospital managers need to adopt measures in order to make these gold-standard procedures cost neutral. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Chiu, Yu-Jen; Liao, Wen-Chieh; Wang, Tien-Hsiang; Shih, Yu-Chung; Ma, Hsu; Lin, Chih-Hsun; Wu, Szu-Hsien; Perng, Cherng-Kang
2017-08-01
Despite significant advances in medical care and surgical techniques, pressure sore reconstruction is still prone to elevated rates of complication and recurrence. We conducted a retrospective study to investigate not only complication and recurrence rates following pressure sore reconstruction but also preoperative risk stratification. This study included 181 ulcers underwent flap operations between January 2002 and December 2013 were included in the study. We performed a multivariable logistic regression model, which offers a regression-based method accounting for the within-patient correlation of the success or failure of each flap. The overall complication and recurrence rates for all flaps were 46.4% and 16.0%, respectively, with a mean follow-up period of 55.4 ± 38.0 months. No statistically significant differences of complication and recurrence rates were observed among three different reconstruction methods. In subsequent analysis, albumin ≤3.0 g/dl and paraplegia were significantly associated with higher postoperative complication. The anatomic factor, ischial wound location, significantly trended toward the development of ulcer recurrence. In the fasciocutaneous group, paraplegia had significant correlation to higher complication and recurrence rates. In the musculocutaneous flap group, variables had no significant correlation to complication and recurrence rates. In the free-style perforator group, ischial wound location and malnourished status correlated with significantly higher complication rates; ischial wound location also correlated with significantly higher recurrence rate. Ultimately, our review of a noteworthy cohort with lengthy follow-up helped identify and confirm certain risk factors that can facilitate a more informed and thoughtful pre- and postoperative decision-making process for patients with pressure ulcers. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Kim, P S; Gottlieb, J R; Harris, G D; Nagle, D J; Lewis, V L
1987-01-01
The anatomic distribution and potential arterial flow patterns of the circumflex scapular artery were investigated by Microfil injection. These studies demonstrated that the circumflex scapular artery lies within the dorsal thoracic fascia, which plays a significant role in the circulation of the overlying skin and subcutaneous tissue. We conclude that scapular/parascapular flaps are fasciocutaneous flaps, the dorsal thoracic fascia can be transferred as a free flap without its overlying skin and subcutaneous tissue, and intercommunication exists between the myocutaneous perforators of the latissimus dorsi myocutaneous flap and the vascular plexus of the dorsal thoracic fascia. We present microvascular cases in which the vascular properties of the dorsal thoracic fascia facilitated wound closure with free fascia flaps or expanded cutaneous or myocutaneous flaps.
Uemura, Tetsuji; Watanabe, Hidekata; Masumoto, Kazuyuki; Kikuchi, Mamoru; Satake, Yoshiyasu; Yanai, Tetsu; Harada, Yoshimi; Ishihara, Yasuhiro; Yasuta, Masato
2016-04-01
The aim of this study was to review the results of a cohort of patients based on our experience with a new technique for total lower eyelid reconstruction after a large defect caused by malignant tumor and trauma. A scapha cartilage graft with small skin on a vascularized propeller flap was used for 16 cases requiring lower eyelid reconstruction. Patients were identified from a database, and a retrospective case note review was conducted. The scapha cartilage graft was sutured to the margin of the defect of the palpebral conjunctiva and tarsus. The propeller flap, rotated by a perforator-based lateral orbital flap or a subcutaneous-based nasolabial flap, was vascularized on the scapha cartilage graft as anterior lining of the lower eyelid. The follow-up, including results of slit-lamp examination, lasted for varying periods, but often it was for 12 months. The scapha cartilage graft with small skin on a vascularized propeller flap was viable in all cases. Slit-lamp examination detected no irritation or injury of the conjunctiva and cornea, and visual acuity was maintained in all cases. A deformity in the donor helix by this technique was also improved by getting a smaller skin harvested from the scapha. Use of the scapha cartilage graft with small skin on a vascularized propeller flap allows for a good fit to the orbit, short operative time under local anesthesia, good graft viability, and a good esthetic result with minimal donor site morbidity.
Stalder, Mark Winston; Wise, Matthew Whitten; Dupin, Charles L.; St Hilaire, Hugo
2014-01-01
High energy injuries to the upper face present challenging reconstructive problems. In some cases, initial reconstructive efforts result in unfavorable outcomes that require secondary intervention. Chimeric free flaps based on the subscapular system offer the tissue components and volume needed for these complex reconstructions. This is a series of five patients who underwent secondary reconstruction of the middle and upper face following traumatic injury. Mechanism of injury, prior attempts at reconstruction, and characteristics of the tissue defects and the flaps used in their reconstruction are described. Two patients were female and three were male. Three injuries resulted from gunshot wounds, and two from motor vehicle accidents. All patients had multiple prior failed attempts at reconstruction using local/regional tissue. Defects included symptomatic oronasal or oro-orbital fistulas, enophthalmos, and forehead contour deformities. Two of the flaps used included scapular bone and latissimus muscular components, and three included scapular bone and thoracodorsal artery perforator-based skin paddle components. All free tissue transfers were successful, and no patients suffered significant complications. Chimeric free flaps based on the subscapular system offer a valuable secondary strategy for reconstruction of composite defects of the upper face when other options have been exhausted through previous efforts. PMID:25709752
Wu, Liza C; Iteld, Lawrence; Song, David H
2008-06-01
Autologous breast reconstruction with the transverse rectus abdominis musculocutaneous (TRAM) flap is traditionally based on either the superior epigastric vessels (pedicled) or the deep inferior system (free). In the overweight and obese population, both techniques have been shown to have increased complications of the reconstructed breast. Another alternative is supercharging the flap by anastamosing the deep inferior epigastric vessels to either the internal mammary or thoracodorsal systems. We present a single surgeon's experience with unilateral TRAM reconstructions supercharged to either the thoracodorsal vessels, the internal mammary system, or in one case, perforator vessels in overweight and obese patients. Nineteen consecutive overweight or obese patients underwent delayed or immediate, unilateral autologous breast reconstruction with supercharged TRAM flaps between November 2000 and November 2004. The patients ranged in age from 28 to 66 years (average 49) and had an average body mass index (BMI) of 29.5 (24.9-38.3). Twelve patients had a BMI between 25 and 29.9 kg/m2; 7 patients had BMI > or =30 kg/m2. Left-sided reconstructions were 13; right-sided reconstructions were 6. Supercharging was performed by anastamosing the deep inferior epigastric artery and vein to the thoracodorsal vessels, internal mammary vessels, or perforator vessels. Follow-up ranged from 6 to 54 months. There was a qualitative increase in blood flow measured by audible Doppler signals in all patients after the arterial and venous anastamoses. There were no cases of partial or complete flap loss. One patient had a hematoma and subsequently developed minor fat necrosis. One patient had an infection of the reconstructed breast. There were no donor site complications. Supercharging the TRAM flap by means of microvascular augmentation of the deep inferior epigastric vessels provides a safe and effective breast reconstruction in the overweight and obese population with no additional morbidity.
Santanelli, Fabio; Longo, Benedetto; Angelini, Matteo; Laporta, Rosaria; Paolini, Guido
2011-05-01
The deep inferior epigastric perforator (DIEP) flap is considered the definitive standard for autologous breast reconstruction because of its ability to restore shape, its consistency, and its static and dynamic symmetry, but the degree of spontaneous sensory recovery is still widely discussed. To clarify the real need for sensitive nerve coaptation, return of sensibility in DIEP flaps was investigated using a pressure-specifying sensory device. Thirty consecutive patients with breast cancer scheduled for modified radical mastectomy, axillary node dissection, and immediate reconstruction with cutaneous-adipose DIEP flaps without nerve repair were enrolled in the study. Sensibility for one and two points, static and moving, was tested preoperatively on the breasts and abdomen, and postoperatively at 6 and 12 months on the DIEP flaps. A t test was used for comparison of paired data and to investigate which factors affected sensory recovery. Preoperative healthy breast and abdomen pressure thresholds were lower for two-point than one-point discrimination and for moving discriminations compared with static ones at 6 and 12 months. Although they were significantly higher than those for contralateral healthy breasts (p < 0.05), pressure thresholds in DIEP flaps at 12 months were lower than at 6 months, showing a significant progressive sensory recovery (p < 0.05). At 12 months postoperatively, the best sensibility recovery was found at the inferior lateral quadrant, the worst at the superior medial quadrant. Age and flap weight were factors related to the performance of sensory recovery. DIEP flap transfer for immediate breast reconstruction undergoes satisfactory progressive spontaneous sensitive recovery at 6 and 12 months after surgery, and operative time spent dissecting sensitive perforator branches and their coaptation in recipient site could be spared.
Preservation of lower extremity amputation length using muscle perforator free flaps.
Hallock, G G
2008-06-01
Coverage of any lower extremity amputation stump must be durable to resist external forces, well contoured, and thin enough for proper shoewear or prothesis fitting. Preservation of bone length to maximise the ability to ambulate is also of paramount importance. If local soft tissues are inadequate to fulfil these prerequisites, consideration of a microsurgical tissue transfer is a reasonable option, especially to cover bone or save a major joint. Muscle perforator free flaps, as shown in this series of eight patients using four different donor sites, are a versatile alternative for the necessary soft tissue augmentation. Multiple choices are available and often even from the involved lower extremity to minimise further morbidity. The vascular pedicles of this genré of flaps are relatively exceedingly long and of respectable calibre to facilitate reaching an appropriate recipient site. They can be sensate if desired. Of course, muscle function is by definition preserved. Complications are minimal and usually related to the reason for the amputation in the first place.
Butterworth, C J; Rogers, S N
2017-12-01
This aim of this report is to describe the development and evolution of a new surgical technique for the immediate surgical reconstruction and rapid post-operative prosthodontic rehabilitation with a fixed dental prosthesis following low-level maxillectomy for malignant disease.The technique involves the use of a zygomatic oncology implant perforated micro-vascular soft tissue flap (ZIP flap) for the primary management of maxillary malignancy with surgical closure of the resultant maxillary defect and the installation of osseointegrated support for a zygomatic implant-supported maxillary fixed dental prosthesis.The use of this technique facilitates extremely rapid oral and dental rehabilitation within a few weeks of resective surgery, providing rapid return to function and restoring appearance following low-level maxillary resection, even in cases where radiotherapy is required as an adjuvant treatment post-operatively. The ZIP flap technique has been adopted as a standard procedure in the unit for the management of low-level maxillary malignancy, and this report provides a detailed step-by-step approach to treatment and discusses modifications developed over the treatment of an initial cohort of patients.
Bosse, Gerhard; Mynarek, Georg Karl; Berg, Thomas; Tindholdt, Tyge Tind; Tønseth, Kim Alexander
2017-01-01
Background: The study was undertaken to provide a more complete picture of donor-site morbidity following the deep inferior epigastric artery perforator (DIEAP) flap harvest in breast reconstruction. Most studies evaluating this subject have been performed using ultrasonography. Computed tomography (CT) might provide valuable information. Methods: In 14 patients who were reconstructed with a DIEAP flap, donor-site morbidity was assessed by comparing routine preoperative CT abdomen with CT abdomen performed 2 years postoperatively. The anteroposterior diameter and transverse diameter (TD) of the rectus muscle were measured bilaterally within 4 standardized zones. Diastasis recti abdominis (DRA) was measured in the same zones. The abdominal wall was assessed for hernias, bulging, and seromas. Results: The operated rectus muscle had a significantly increased anteroposterior diameter in 2 zones and decreased TD in 1 zone compared with preoperative measurements. Comparing the operated and nonoperated rectus muscles, the former had a significantly decreased TD in 1 zone. Supraumbilical DRA was significantly decreased with surgery, whereas infraumbilical DRA was significantly increased. No new hernias or bulging were found. Two patients had seroma formation in the abdominal wall. Conclusions: Symmetry of the 2 hemiabdomens is well preserved after DIEAP flap harvest; however, significant changes to the rectus muscles and DRA were observed. Hernia formation does not seem to be a postoperative complication of importance. The study indicates that DIEAP flaps result in limited donor-site morbidity, which for most patients does not outweigh the benefits of free perforator flap breast reconstruction. PMID:28831346
Beltrán, Aldo G.; Romero, Camilo J.
2016-01-01
Background: The management of contractures and soft tissue defects in the proximal interphalangeal (PIP) finger joint remains a challenge. We report a transposition flap from the lateral skin of the proximal phalanx that is based on perforating branches of the digital arteries and can be used safely for both palmar and dorsal cover defects. Methods: We first completed an anatomic study, dissecting 20 fingers in fresh cadavers with arterial injections and made the new flap in patients with dorsal or palmar defects in PIP joints. Results: In cadavers, we can reveal 4 constant branches from each digital artery in the proximal phalanx, with the more distal just in the PIP joint constituting the flap pedicle. Between February 2010 and February 2015, we designed 33 flaps in 29 patients, 7 for dorsal and 26 for palmar defects, with no instances of flap necrosis and 4 distal epidermolysis. The patients were between 4 and 69 years with no major complications, and all of the skin defects in the PIP joint were resolved satisfactorily without any relevant sequelae at the donor site. Conclusions: This flap procedure is an easy, reliable, versatile, and safe technique, and could be an important tool for the management of difficult skin defects and contractures at the PIP joint level. PMID:28082850
Huang, Shih-Tsai; Liu, Wen-Chung; Chen, Lee-Wei; Yang, Kuo-Chung
2015-05-01
Synchronous double oral cancer represents the minority of cases of head and neck cancer. After tumor ablation, 2 separate oromandibular defects, even combined with a through-and-through oral defect, pose a serious reconstructive challenge. The ideal method for reconstruction remains controversial. Based on the peroneal vessel axis, a chimeric double-skin paddle peroneal fasciocutaneous or fibular osteomyocutaneous flap could be designed to accomplish the difficult reconstruction. Six male patients, each with 2 separate oromandibular defects after tumor ablation of synchronous double oral cancer, received double-skin paddle flap reconstruction with 3 peroneal fasciocutaneous and 3 fibular osteomyocutaneous flaps. All 6 flaps survived; however, complications included 1 skin paddle lost due to insufficient perfusion of a visible perforator, and 1 superficial necrosis occurring over the tip of a longer skin paddle. One postoperative intraoral infection and 1 donor site infection were also reported. During follow-up, 3 months later, 1 patient succumbed to local recurrence and bony metastasis. One patient developed a new cancer in the maxillary gingiva, and another had osteoradionecrosis 8 months later. Four patients gained acceptable cosmesis with good oral competence. A chimeric flap based on the peroneal artery could provide a segment of fibular bone, 1 or 2 skin paddles, and a cuff of the flexor hallucis longus muscle simultaneously. For 1-stage reconstruction of separate oromandibular defects after tumor ablation of synchronous double oral cancer, this design could provide all components at 1 transfer.
Azuma, Shuchi; Arikawa, Masaki; Miyamoto, Shimpei
2017-11-01
We report on a patient with a recurrence of oral cancer involving a cervical lymph node. The patient's postexcision cervical skin defect was nearly circular in shape, and the size was about 12 cm in diameter. The defect was successfully reconstructed with a boomerang-shaped pectoralis major musculocutaneous flap whose skin paddle included multiple intercostal perforators of the internal mammary vessels. This flap design is effective for reconstructing an extensive neck skin defect and enables primary closure of the donor site with minimal deformity.
Soft tissue coverage of the elbow in a developing country.
Pirela-Cruz, Miguel A; Reddy, Kartheek K; Higgs, Matthew
2007-09-01
Two cases that required soft tissue coverage to the anterior aspect of the elbow are presented. A fasciocutaneous intercostal perforator chest wall flap was used for one patient when only skin and fascia coverage was required. A latissimus dorsi myocutaneous flap was used to provide soft tissue coverage and supply motor power for elbow flexion after contracture release in the other. The surgical techniques for each of these flaps are discussed in the context of addressing soft tissue traumatic injuries about the elbow in a developing country with limited resources.
An international comparison of reimbursement for DIEAP flap breast reconstruction.
Reid, A W N; Szpalski, C; Sheppard, N N; Morrison, C M; Blondeel, P N
2015-11-01
The deep inferior epigastric artery perforator (DIEAP) flap is currently considered the gold standard for autologous breast reconstruction. With the current economic climate and health cutbacks, we decided to survey reimbursement for DIEAP flaps performed at the main international centres in order to assess whether they are funded consistently. Data were collected confidentially from the main international centres by an anonymous questionnaire. Our results illustrate the wide disparity in international DIEAP flap breast reconstruction reimbursement: a unilateral DIEAP flap performed in New York, USA, attracts €20,759, whereas the same operation in Madrid, Spain, will only be reimbursed for €300. Only 35.7% of the surgeons can set up their own fee. Moreover, 85.7% of the participants estimated that the current fees are insufficient, and most of them feel that we are evolving towards an even lower reimbursement rate. In 55.8% of the countries represented, there is no DIEAP-specific coding; in comparison, 74.4% of the represented countries have a specific coding for transverse rectus abdominis (TRAM) flaps. Finally, despite the fact that DIEAP flaps have become the gold standard for breast reconstruction, they comprise only a small percentage of all the total number of breast reconstruction procedures performed (7-15%), with the only exception being Belgium (40%). Our results demonstrate that DIEAP flap breast reconstruction is inconsistently funded. Unfortunately though, it appears that the current reimbursement offered by many countries may dissuade institutions and surgeons from offering this procedure. However, substantial evidence exists supporting the cost-effectiveness of perforator flaps for breast reconstruction, and, in our opinion, the long-term clinical benefits for our patients are so important that this investment of time and money is absolutely essential. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Uda, Hirokazu; Tomioka, Yoko Katsuragi; Sarukawa, Syunji; Sunaga, Ataru; Kamochi, Hideaki; Sugawara, Yasusih; Yoshimura, Kotaro
2016-09-01
The reduced incidence of donor site morbidity after deep inferior epigastric perforator (DIEP) flap is because the rectus muscle and its fascia are preserved. However, no study has proved that trunk flexion recovers not by the compensatory effect of the contralateral rectus muscle but by reinnervation of the ipsilateral rectus muscle. We hypothesized that if sufficient reinnervation occurs, patients who undergo single-pedicled DIEP (S-DIEP) flap or double-pedicled DIEP (D-DIEP) flap breast reconstruction would have similar levels of preoperative trunk flexion. To determine this, we investigated perioperative changes in trunk flexor muscle ability quantitatively using an isokinetic dynamometer in patients who had received S-DIEP or D-DIEP. Patients who underwent breast reconstruction with S-DIEP (n = 37) and D-DIEP (n = 30) were included in this study. Pre- and postoperative trunk flexor muscle ability was measured prospectively by an isokinetic dynamometer in all patients. Postoperative abdominal pain and stiffness, patients' activity, and incidence of bulging were also investigated. Six months after surgery, the trunk flexor muscle ability recovered and did not significantly decrease subsequently in either group. This finding was consistent with the result that patients' activities and the incidence of bulging were similar between the two groups. Our results show that reinnervation of the rectus muscle can be confirmed at 6 months after DIEP flap elevation. Thus, we recommend D-DIEP flap without concern for abdominal wall weakness, especially in patients with multiple abdominal scars and who require breast tissue exceeding the amount of tissue that can be transferred with S-DIEP flap. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Cost-effectiveness analysis of implants versus autologous perforator flaps using the BREAST-Q.
Matros, Evan; Albornoz, Claudia R; Razdan, Shantanu N; Mehrara, Babak J; Macadam, Sheina A; Ro, Teresa; McCarthy, Colleen M; Disa, Joseph J; Cordeiro, Peter G; Pusic, Andrea L
2015-04-01
Reimbursement has been recognized as a physician barrier to autologous reconstruction. Autologous reconstructions are more expensive than prosthetic reconstructions, but provide greater health-related quality of life. The authors' hypothesis is that autologous tissue reconstructions are cost-effective compared with prosthetic techniques when considering health-related quality of life and patient satisfaction. A cost-effectiveness analysis from the payer perspective, including patient input, was performed for unilateral and bilateral reconstructions with deep inferior epigastric perforator (DIEP) flaps and implants. The effectiveness measure was derived using the BREAST-Q and interpreted as the cost for obtaining 1 year of perfect breast health-related quality-adjusted life-year. Costs were obtained from the 2010 Nationwide Inpatient Sample. The incremental cost-effectiveness ratio was generated. A sensitivity analysis for age and stage at diagnosis was performed. BREAST-Q scores from 309 patients with implants and 217 DIEP flap reconstructions were included. The additional cost for obtaining 1 year of perfect breast-related health for a unilateral DIEP flap compared with implant reconstruction was $11,941. For bilateral DIEP flaps compared with implant reconstructions, the cost for an additional breast health-related quality-adjusted life-year was $28,017. The sensitivity analysis demonstrated that the cost for an additional breast health-related quality-adjusted life-year for DIEP flaps compared with implants was less for younger patients and earlier stage breast cancer. DIEP flaps are cost-effective compared with implants, especially for unilateral reconstructions. Cost-effectiveness of autologous techniques is maximized in women with longer life expectancy. Patient-reported outcomes findings can be incorporated into cost-effectiveness analyses to demonstrate the relative value of reconstructive procedures.
Thoma, Achilleas; Veltri, Karen; Khuthaila, Dana; Rockwell, Gloria; Duku, Eric
2004-05-01
This study compared the deep inferior epigastric perforator (DIEP) flap and the free transverse rectus abdominis myocutaneous (TRAM) flap in postmastectomy reconstruction using a cost-effectiveness analysis. A decision analytic model was used. Medical costs associated with the two techniques were estimated from the Ontario Ministry of Health Schedule of Benefits for 2002. Hospital costs were obtained from St. Joseph's Healthcare, a university teaching hospital in Hamilton, Ontario, Canada. The utilities of clinically important health states related to breast reconstruction were obtained from 32 "experts" across Canada and converted into quality-adjusted life years. The probabilities of these various clinically important health states being associated with the DIEP and free TRAM flaps were obtained after a thorough review of the literature. The DIEP flap was more costly than the free TRAM flap ($7026.47 versus $6508.29), but it provided more quality-adjusted life years than the free TRAM flap (28.88 years versus 28.53 years). The baseline incremental cost-utility ratio was $1464.30 per quality-adjusted life year, favoring adoption of the DIEP flap. Sensitivity analyses were performed by assuming that the probabilities of occurrence of hernia, abdominal bulging, total flap loss, operating room time, and hospital stay were identical with the DIEP and free TRAM techniques. By assuming that the probability of postoperative hernia for the DIEP flap increased from 0.008 to 0.054 (same as for TRAM flap), the incremental cost-utility ratio changed to $1435.00 per quality-adjusted life year. A sensitivity analysis was performed for the complication of hernia because the DIEP flap allegedly diminishes this complication. Increasing the probability of abdominal bulge from 0.041 to 0.103 for the DIEP flap changed the ratio to $2731.78 per quality-adjusted life year. When the probability of total flap failure was increased from 0.014 to 0.016, the ratio changed to $1384.01 per quality-adjusted life year. When the time in the operating room was assumed to be the same for both flaps, the ratio changed to $4026.57 per quality-adjusted life year. If the hospital stay was assumed to be the same for both flaps, the ratio changed to $1944.30 per quality-adjusted life year. On the basis of the baseline calculation and sensitivity analyses, the DIEP flap remained a cost-effective procedure. Thus, adoption of this new technique for postmastectomy reconstruction is warranted in the Canadian health care system.
Bosc, R; Fitoussi, A; Pigneur, F; Tacher, V; Hersant, B; Meningaud, J-P
2017-08-01
The augmented reality on smart glasses allows the surgeon to visualize three-dimensional virtual objects during surgery, superimposed in real time to the anatomy of the patient. This makes it possible to preserve the vision of the surgical field and to dispose of added computerized information without the need to use a physical surgical guide or a deported screen. The three-dimensional objects that we used and visualized in augmented reality came from the reconstructions made from the CT-scans of the patients. These objects have been transferred through a dedicated application on stereoscopic smart glasses. The positioning and the stabilization of the virtual layers on the anatomy of the patients were obtained thanks to the recognition, by the glasses, of a tracker placed on the skin. We used this technology, in addition to the usual locating methods for preoperative planning and the selection of perforating vessels for 12 patients operated on a breast reconstruction, by perforating flap of deep lower epigastric artery. The "hands-free" smart glasses with two stereoscopic screens make it possible to provide the reconstructive surgeon with binocular visualization in the operative field of the vessels identified with the CT-scan. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Beltrán, Aldo G; Romero, Camilo J
2017-01-01
Background: The management of contractures and soft tissue defects in the proximal interphalangeal (PIP) finger joint remains a challenge. We report a transposition flap from the lateral skin of the proximal phalanx that is based on perforating branches of the digital arteries and can be used safely for both palmar and dorsal cover defects. Methods: We first completed an anatomic study, dissecting 20 fingers in fresh cadavers with arterial injections and made the new flap in patients with dorsal or palmar defects in PIP joints. Results: In cadavers, we can reveal 4 constant branches from each digital artery in the proximal phalanx, with the more distal just in the PIP joint constituting the flap pedicle. Between February 2010 and February 2015, we designed 33 flaps in 29 patients, 7 for dorsal and 26 for palmar defects, with no instances of flap necrosis and 4 distal epidermolysis. The patients were between 4 and 69 years with no major complications, and all of the skin defects in the PIP joint were resolved satisfactorily without any relevant sequelae at the donor site. Conclusions: This flap procedure is an easy, reliable, versatile, and safe technique, and could be an important tool for the management of difficult skin defects and contractures at the PIP joint level.
Tsuji, Naoko; Suga, Hirotaka; Uda, Koichi; Sugawara, Yasushi
2008-01-01
The anterolateral thigh flap is thought to have minor donor site morbidity, but muscle dissection is unavoidable when skin perforator vessels run through the vastus lateralis muscle. The purpose of this study was to investigate the functional problems associated with the anterolateral thigh flap donor site. We evaluated 12 patients who underwent free anterolateral thigh flap transfer between March 2003 and November 2005. A questionnaire and dynamic functional evaluation of the knee joint using the Biodex System were performed preoperatively and 6 months postoperatively. No patients reported any disturbance in their daily life. No significant differences were found between donor and normal thighs on isokinetic power tests of the quadriceps muscle. The function of the donor site after harvesting the anterolateral thigh flap was maintained. Damage to or functional disturbance of the donor site is minimal even if muscle is injured when harvesting the flap. (c) 2008 Wiley-Liss, Inc. Microsurgery, 2008
Ravipati, Nagesh B; Pockaj, Barbara A; Harold, Kristi L
2007-08-01
The transverse rectus abdominus muscle (TRAM) flap is one of the treatment options for breast reconstruction. TRAM flap reconstruction donor site herniation rates range from 1% to 8.8%. Traditionally, these hernias were treated by an open primary repair with or without the addition of onlay mesh. We report laparoscopic approach to treat TRAM and deep inferior epigastric perforator flap (DIEP) harvest site hernias with mesh. We treated 5 patients, 4 from TRAM and 1 from DIEP flap harvest site hernias during the period of October 2003 to January 2006. Two of these patients underwent previous open mesh repair with recurrence. All of these patients underwent laparoscopic hernia repair using polytetrafluoroethylene dual mesh. Follow-up ranged 6 to 31 months without any recurrences. Laparoscopic mesh repair of ventral hernias located at TRAM and DIEP flap harvest sites can be performed safely and with a low rate of recurrence.
Azuma, Shuchi; Arikawa, Masaki
2017-01-01
Summary: We report on a patient with a recurrence of oral cancer involving a cervical lymph node. The patient’s postexcision cervical skin defect was nearly circular in shape, and the size was about 12 cm in diameter. The defect was successfully reconstructed with a boomerang-shaped pectoralis major musculocutaneous flap whose skin paddle included multiple intercostal perforators of the internal mammary vessels. This flap design is effective for reconstructing an extensive neck skin defect and enables primary closure of the donor site with minimal deformity. PMID:29263975
NASA Technical Reports Server (NTRS)
Pennock, A. P.; Swift, G.; Marbert, J. A.
1975-01-01
Externally blown flap models were tested for noise and performance at one-fifth scale in a static facility and at one-tenth scale in a large acoustically-treated wind tunnel. The static tests covered two flap designs, conical and ejector nozzles, third-flap noise-reduction treatments, internal blowing, and flap/nozzle geometry variations. The wind tunnel variables were triple-slotted or single-slotted flaps, sweep angle, and solid or perforated third flap. The static test program showed the following noise reductions at takeoff: 1.5 PNdB due to treating the third flap; 0.5 PNdB due to blowing from the third flap; 6 PNdB at flyover and 4.5 PNdB in the critical sideline plane (30 deg elevation) due to installation of the ejector nozzle. The wind tunnel program showed a reduction of 2 PNdB in the sideline plane due to a forward speed of 43.8 m/s (85 kn). The best combination of noise reduction concepts reduced the sideline noise of the reference aircraft at constant field length by 4 PNdB.
Offodile, Anaeze C; Chatterjee, Abhishek; Vallejo, Sergio; Fisher, Carla S; Tchou, Julia C; Guo, Lifei
2015-04-01
Computed tomographic angiography is a diagnostic tool increasingly used for preoperative vascular mapping in abdomen-based perforator flap breast reconstruction. This study compared the use of computed tomographic angiography and the conventional practice of Doppler ultrasonography only in postmastectomy reconstruction using a cost-utility model. Following a comprehensive literature review, a decision analytic model was created using the three most clinically relevant health outcomes in free autologous breast reconstruction with computed tomographic angiography versus Doppler ultrasonography only. Cost and utility estimates for each health outcome were used to derive the quality-adjusted life-years and incremental cost-utility ratio. One-way sensitivity analysis was performed to scrutinize the robustness of the authors' results. Six studies and 782 patients were identified. Cost-utility analysis revealed a baseline cost savings of $3179, a gain in quality-adjusted life-years of 0.25. This yielded an incremental cost-utility ratio of -$12,716, implying a dominant choice favoring preoperative computed tomographic angiography. Sensitivity analysis revealed that computed tomographic angiography was costlier when the operative time difference between the two techniques was less than 21.3 minutes. However, the clinical advantage of computed tomographic angiography over Doppler ultrasonography only showed that computed tomographic angiography would still remain the cost-effective option even if it offered no additional operating time advantage. The authors' results show that computed tomographic angiography is a cost-effective technology for identifying lower abdominal perforators for autologous breast reconstruction. Although the perfect study would be a randomized controlled trial of the two approaches with true cost accrual, the authors' results represent the best available evidence.
Postoperative morphine requirements of free TRAM and DIEP flaps.
Kroll, S S; Sharma, S; Koutz, C; Langstein, H N; Evans GRD; Robb, G L; Chang, D W; Reece, G P
2001-02-01
In a review of the charts of 158 patients who had undergone breast reconstruction with free transverse rectus abdominis musculocutaneous (TRAM) or deep inferior epigastric perforator (DIEP) flaps and who were treated for postoperative pain with morphine administered by a patient-controlled analgesia pump, the total dose of morphine administered during hospitalization for the flap transfer was measured. Patients whose treatment was supplemented by other intravenous narcotics were excluded from the study. The mean amount of morphine per kilogram required by patients who had reconstruction with DIEP flaps (0.74 mg/kg, n = 26) was found to be significantly less than the amount required by patients who had reconstruction with TRAM flaps (1.65 mg/kg; n = 132; p < 0.001). DIEP flap patients also remained in the hospital less time (mean, 4.73 days) than did free TRAM flap patients (mean, 5.21 days; p = 0.026), but the difference was less than one full hospital day. It was concluded that the use of the DIEP flap does reduce the patient requirement for postoperative pain medication and therefore presumably reduces postoperative pain. It may also slightly shorten hospital stay.
Di Lorenzo, Sara; Zabbia, Giovanni; Corradino, Bartolo; Tripoli, Massimiliano; Pirrello, Roberto; Cordova, Adriana
2017-12-04
BACKGROUND Basal cell carcinoma (BCC) greater than 5 cm in diameter is called giant basal cell carcinoma (GBCC), or super giant basal cell carcinoma if it has a diameter larger than 20 cm. Giant BCC only accounts for 0.5% of BCCs and super giant BCC is exceedingly rare. On account of their rarity, there are no established guidelines for GBCC treatment. CASE REPORT We describe a peculiar case of an 82-year-old woman with a GBCC carcinoma of the lower abdominal wall. The tumor was surgically removed with ipsilateral inguinal lymph nodes and the abdominal wall was reconstructed immediately with a pedicled deep inferior epigastric artery perforator (DIEP) flap. CONCLUSIONS Treatment of giant basal cell carcinoma is often difficult, especially in elderly patients with poor general health and multiple pathologies. The pedicled DIEP flap is rotated to cover the loss of substance without tension, and it is easy to harvest and transfer. This flap allowed a good result without local or systemic complication. We present this report as a reminder of the occasional occurrence of extremely aggressive BCCs. We believe that, especially for rare tumors like these, it is very useful for the entire scientific community to publish these cases and the therapeutic strategies used to treat them.
Oksüz, Sinan; Ulkür, Ersin; Tuncer, Serhan; Sever, Celalettin; Karagöz, Hüseyin
2013-04-01
The complexity of managing large soft-tissue defects at the elbow region by conventional techniques arises from the difficulty of providing sufficient tissue with adequate elasticity and durability. Reconstruction options that allow early mobilisation and avoid the risk of functional loss should be considered to achieve defect closure at the elbow region. A 21-year-old man presented with a congenital giant hairy nevus on his left upper extremity. The nevus was excised and the resulting raw surface after the excision was covered with a split-thickness skin graft except for the elbow region. The elbow was covered in one stage with an ipsilateral 24 cm long pedicled thoracodorsal artery perforator (TDAP) flap. The follow-up examination 3 years after total reconstruction demonstrated durable elbow support provided by the TDAP flap. The patient revealed no complaint considering pain or sensitivity even when exposed to mechanical stress. Split-thickness skin grafting of the large superficial defects is almost always possible; however, impairment of the function on joint areas due to gradual contraction and skin graft propensity to ulcers under mechanical stresses can be devastating. The elbow is a weight-bearing area of the body. Elbow defects require durable and thin soft-tissue coverage and the tissue cover must possess excellent elastic properties to re-establish elbow mobility. The TDAP flap is an ideal choice for elbow soft-tissue defects. The longest pedicle length reported for the TDAP flap is 23 cm. In our case, the pedicle length was 24 cm and it was possible to transfer this flap to the elbow on its pedicle. A pedicled TDAP skin flap so as to provide elbow coverage in one stage is a useful choice to retain in one's armamentarium. Copyright © 2012 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Bodin, Frédéric; Dissaux, Caroline; Dupret-Bories, Agnes; Schohn, Thomas; Fiquet, Caroline; Bruant-Rodier, Catherine
2016-01-01
The transverse musculocutaneous gracilis (TMG) flap has become a common solution for breast reconstruction. However, the safe skin paddle limits are not yet understood. In this study, we attempted to address this issue based on our experiences with inferior and posterior skin paddle extension. Forty-four breast reconstructions with TMG flaps performed between November 2010 and January 2014 were analyzed retrospectively. For the first 20 cases, the flap skin paddle was extended 3 cm posteriorly to the middle thigh (group 1). For the next 20 flaps (group 2), the posterior tip was limited to this line, whereas more fat was recruited inferiorly. In the four cases of group 3, the skin flap was extended posteriorly with a second vascular pedicle from the profunda artery perforator (PAP) flap. The weights and the dimensions of the flaps, operating durations, and postoperative complications of the entire series were analyzed. Groups 1 and 2 were statistically compared. Flap complications were statistically more frequent in group 1 compared with group 2 (45 vs. 0%, P = 0.0012); 40% posterior flap tip necrosis was observed in group 1. Conversely, donor site complications were statistically more frequent in group 2 than in group 1 (40 vs. 5%, P = 0.019) with 35% inner thigh dehiscence. In the TMG with extended PAP flap group, the operating duration was 77 min longer compared with the rest of the series with no donor site complications. In one case, limited necrosis occurred at the anterior skin tip. Harvesting the posterior portion of the TMG up to the middle of the posterior thigh may lead to partial flap necrosis. Extending subcutaneous fat removal under the inferior skin incision may increase the risk of donor site complications. Adding a second vascular pedicle from the PAP flap may improve posterior TMG tip perfusion at the expense of a longer operation. © 2015 Wiley Periodicals, Inc.
Jaiswal, Rohit; Pu, Lee L Q
2013-04-01
Major facial trauma injuries often require complex repair. Traditionally, the reconstruction of such injuries has primarily utilized only free tissue transfer. However, the advent of newer, contemporary procedures may lead to potential reconstructive improvement through the use of complementary procedures after free flap reconstruction. An 18-year-old male patient suffered a major left facial degloving injury resulting in soft-tissue defect with exposed zygoma, and parietal bone. Multiple operations were undertaken in a staged manner for reconstruction. A state-of-the-art free anterolateral thigh (ALT) perforator flap and Medpor implant reconstruction of the midface were initially performed, followed by flap debulking, lateral canthopexy, midface lift with redo canthopexy, scalp tissue expansion for hairline reconstruction, and epidermal skin grafting for optimal skin color matching. Over a follow-up period of 2 years, a good and impressive reconstructive result was achieved through the use of multiple contemporary reconstructive procedures following an excellent free ALT flap reconstruction. Multiple staged reconstructions are essential in producing an optimal outcome in this complex facial injury that would likely not have been produced through a 1-stage traditional free flap reconstruction. Utilizing multiple, sequential contemporary surgeries may substantially improve outcome through the enhancement and refinement of results based on possibly the best initial soft-tissue reconstruction.
Spanio di Spilimbergo, Stefano; Nordera, Paolo; Mardini, Samir; Castiglione, Giusy; Chim, Harvey; Pinna, Vittore; Brunello, Massimo; Cusino, Claudio; Roberto, Squaquara; Baciliero, Ugo
2017-02-01
In the past 130 years, the temporalis muscle flap has been used for a variety of different indications. In this age of microsurgery and perforator flaps, the temporalis muscle flap still has many useful applications for craniofacial reconstruction. Three hundred sixty-six temporalis muscle flaps were performed in a single center between 1978 and 2012. The authors divided the cases into two series-before and after 1994-because, after 1994, they started to perform free flap reconstructions, and indications for reconstruction with a temporalis muscle flap were changed RESULTS:: In the series after 1994, flaps were most commonly used for reconstruction of defects in the maxilla, mandible, and oropharynx, in addition to facial reanimation and filling of orbital defects. Complications included total flap necrosis (1.6 percent) and partial flap necrosis (10.7 percent). The rate of material extrusion at the donor site decreased after porous polyethylene was uniformly used for reconstruction from 17.1 to 7.9 percent. The pedicled temporalis muscle flap continues to have many applications in craniofacial reconstruction. With increasing use of free flaps, the authors' indications for the pedicled temporalis muscle flap are now restricted to (1) orbital filling for congenital or acquired anophthalmia; (2) filling of unilateral maxillectomy defects; and (3) facial reanimation in selected cases of facial nerve palsy. Therapeutic, IV.
Ellabban, Mohamed A
2016-04-01
A primary repair of external penetrating injury to hypopharyngeal-cervical esophageal (HP-CE) funnel without reinforcement has more complications if compared with muscle reinforcement. The aim of the present study was to assess the outcome of using sternocleidomastoid (SCM) muscle flap for reinforcement of primary repair of HP-CE funnel injury. The study proposed an algorithm for different uses of SCM flap repair according to site and size of funnel perforation. A prospective analysis of 12 patients, who had surgical treatment for external penetrating injuries of HP-CE funnel between January 2011 and September 2014, was recorded. The following factors were studied for each case: demographic data, Revised Trauma Score (RTS), mechanism of injury, time interval between injury and definitive surgical care, injury morphology, any associated injuries, technique of SCM flap used, length of hospital stay, and surgical outcome and complications. They were 10 males and 2 females and the mean age was 31.9 years. The cause of injury was stab wound in 5 (41.7 %) cases, gunshot injury in 4 (33.3 %) cases and 3 (25 %) cases after anterior cervical spine surgery. Isolated injury to HP and CE was recorded in 5 cases (41.7 %) for each site. However, 2 (16.7 %) cases had injury to both HP and CE. Cranially based SCM flap was mainly used in cases with HP injury and caudally based flap in CE cases with some limitations. The whole muscle flap was used in large (≥ 1 cm) defects while and the split muscle flap in small (<1 cm) defects. Oral intake started 7 days postoperatively with only one (8.3 %) case of small leakage, which was treated conservatively. The SCM flap is a very useful and versatile tool in reinforcement of HP-CE funnel injury with the advantages of high success rates of leakage prevention.
Schaverien, Mark V; Dean, Riley A; Myers, Jeffrey N; Fang, Lin; Largo, Rene D; Yu, Peirong
2018-05-03
For organ transplant recipients, cancer secondary to immunosuppressive therapy threatens long-term survival. The associated multiple comorbidities make major free flap reconstruction following cancer surgery a complicated event. This study evaluates the outcomes of free flap reconstruction in this population. A retrospective chart review of all head and neck free flap cases in patients with a history of organ transplantation receiving systemic immunosuppressive therapy between 2005 and 2017 at a single-institution was conducted. Of 57 organ transplant patients, 25 patients (28 flaps) were included. Flaps used included the anterolateral thigh (n = 17), radial forearm (n = 4), latissimus dorsi (n = 3), fibula (n = 2), lateral arm (n = 1), and thoracodorsal artery perforator (n = 1) flaps. The most common organ transplant was kidney, then lung, liver, and heart. Mean inpatient stay was 8.2 days (range, 4-28). Complications occurred in 15 patients, with no total or partial flap losses. Major head and neck free flap reconstructive surgery can be performed safely in organ transplant patients receiving immunosuppressive therapy. Meticulous multidisciplinary care is required to achieve consistently successful outcomes. © 2018 Wiley Periodicals, Inc.
Propeller flaps in eyelid reconstruction.
Rajak, Saul N; Huilgol, Shyamala C; Murakami, Masahiro; Selva, Dinesh
2018-03-14
Propeller flaps are island flaps that reach the recipient site through an axial rotation. The flap has a subcutaneous pedicle on which it pivots, thereby resembling a helicopter propeller. We present our series of propeller flaps for the reconstruction of large eyelid defects. This is a retrospective review of the clinical case notes of eight patients that underwent tumour excision with reconstruction with a cutaneous propeller flap supplied by a non-perforator orbicularis pedicle between July and December 2016. Propeller flaps were used in the reconstruction of five lower lid defects (size range 19 × 5 mm to 25 × 8 mm), one medial canthus defect (13 mm diameter), one complete upper lid defect (42 × 19 mm diameter) and one lid sparing extenteration defect. The flaps were recruited from nasolabial, lateral canthal, temple or medial upper cheek skin. Post-operatively one case had 'trapdooring' which required flap revision at 4 months and one had persistent oedema that settled without intervention. The reconstruction of large eyelid defects is challenging in part because of the paucity of locally available skin. Propeller flaps are a paradigm shift in periocular reconstruction in which the subcutaneous pedicle enables the recruitment of large and highly mobile skin flaps from a wide area of regional tissue.
Liu, B; Hao, X; Goan, M
2000-05-01
To investigate the blood supply patterns and the clinical liability of a leg flap pedicle-included with cutaneous nerve and its concomitant vessels. Fresh cadaver legs with thirty-two in infants and two in adults were anatomically examined after the intravenous injection of the red Chlorinated Poly Vingl Choride (CPVC). Five patients with the soft tissue defects were selected for the treatment with the flap pedicle-included with the cutaneous nerve and its concomitant vessels. Four main cutaneous nerves were found in the leg after they perforated the deep fascia out. They were companioned with their concomitant vessels with different blood-supply pateeerns, which the upper part of the leg was in an axial pattern and the lower part was in a "chain-type anastomosing" pattern. Following the above-mentioned findings, five cases were successfully treated with this led flap. The leg flap should be designed along the cutaneous nerve and its concomitant vessels. When the flap is applied in the area of blood supply with "chain-type anastomosing" pattern, the deep fascia should also be included in the flap.
Duan, Jiazhang; He, Xiaoqing; Xu, Yongqing
2016-07-08
?To summarize the present status and progress of vascular anatomy and preoperative design technology of the anterolateral thigh flap. ?The relative researches focused on vascular anatomy and preoperative design technology of the anterolateral thigh flap were extensively reviewed, analyzed, and summarized. ?Vascular anatomy of the anterolateral thigh flap has been reported by numerous researchers, but perforators' location, origin, course, and the variation of the quantity have been emphasized. Meanwhile, the variation of descending branch, oblique branch, and lateral circumflex femoral artery has also been widely reported. Preoperative design technology of the anterolateral thigh flap includes hand-held Doppler, Color Doppler, CT angiography (CTA), magnetic resonance angiography, digital subtraction angiography, and digital technology, among which the hand-held Doppler is most widely used, and CTA is the most ideal, but each method has its own advantages and disadvantages. ?There is multiple variation of vascular anatomy of the anterolateral thigh flap. Though all kinds of preoperative design technologies can offer strong support to operation of anterolateral thigh flap, a simple, quick, precise, and noninvasive technology is the direction of further research.
Correia Anacleto, J; Mavioso, C; Gouveia, P F; Magalhães, A; Bastos Martins, J; Moura, A; Pinto, D; Cardoso, M J
2016-08-01
The latissimus dorsi flap is a commonly used tissue transfer for volume replacement in partial or total breast reconstruction. In this era of cosmetic awareness and oncoplastic breast surgery, two main defects are related to the conventional technique: the back scar and the bulkiness on the lateral chest wall, under the axilla. Axillary bulking, a disturbing defect for the majority of patients, is a persistent consequence, independent of the technique used, even when the proximal tendon is cut. We describe a new approach, the kite latissimus dorsi flap, consisting of harvesting the flap, partially or totally, with pedicle dissection from the muscle, extending dissection, perforator style if needed, until the external border of the breast (anterior axillary line) is reached. The muscle is then cut at that level, leaving no unnecessary volume under the axilla, which would cause bulkiness and chest wall deformity. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.
Misani, M; Zirak, C; Hau, Lê Thua Trung; De Mey, A; Boeckx, W
2013-08-01
The use of microsurgery in the management of burn sequelae is not a new idea. According to the properties of various types of free flaps different goals can be achieved or various additional procedures have to be combined. We report the comparison of two different free flaps on a single patient for reconstruction of both upper extremities for burn sequelae. A 1-year-old child sustained severe burns on both hands, arms and thorax and was initially only treated conservatively. This resulted in severe contractures. At the age of 4-years a free gracilis flap was selected for reconstruction of his left hand and a free anterolateral thigh flap for the right hand. We noticed a better functional and esthetic result for the gracilis flap associated with a shorter operative time and a minor donor site morbidity. The intraoperative technique and time, postoperative complications, functional and esthetic results and donor site morbidities were studied in the two types of flaps chosen. A review of literature was also performed. Our experience reported a better success of the gracilis muscle flap covered with a split skin graft compared to the anterolateral thigh flap in the reconstruction of hand function after severe burn sequelae. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.
Refining the intrinsic chimera flap: a review.
Agarwal, Jayant P; Agarwal, Shailesh; Adler, Neta; Gottlieb, Lawrence J
2009-10-01
Reconstruction of complex tissue deficiencies in which each missing component is in a different spatial relationship to each other can be particularly challenging, especially in patients with limited recipient vessels. The chimera flap design is uniquely suited to reconstruct these deformities. Chimera flaps have been previously defined in many ways with 2 main categories: prefabricated or intrinsic. Herein we attempt to clarify the definition of a true intrinsic chimeric flap and provide examples of how these constructs provide a method for reconstruction of complex defects. The versatility of the intrinsic chimera flap and its procurement from 7 different vascular systems is described. A clarification of the definition of a true intrinsic chimera flap is described. In addition, construction of flaps from the lateral femoral circumflex, deep circumflex iliac, inferior gluteal, peroneal, subscapular, thoracodorsal, and radial arterial systems is described to showcase the versatility of these chimera flaps. A true intrinsic chimera flap must consist of more than a single tissue type. Each of the tissue components receives its blood flow from separate vascular branches or perforators that are connected to a single vascular source. These vascular branches must be of appropriate length to allow for insetting with 3-dimensional spatial freedom. There are a multitude of sites from which true intrinsic chimera flaps may be harvested.
Double transverse myocutaneous gracilis free flaps for unilateral breast reconstruction.
Werdin, Frank; Haug, Daniel M; Amr, Amro; Schoeller, Thomas
2016-10-01
In cases were the deep inferior epigastric perforator flap (DIEP flap) is not available and unilateral transverse myocutaneous gracilis flap (TMG flap) is not sufficient for breast reconstruction, we perform double TMG flaps as a reconstructive method. In this report, we present our results of the use of double TMG free-flap-transfer for unilateral breast reconstruction. Between August 2004 and June 2012 we performed 58 TMG flaps in 29 patients for unilateral breast reconstruction. Patient data were analyzed and operative outcome (operation time, complication rate and aesthetic results) were investigated. Aesthetic outcome was evaluated retrospectively via photo documentation by an independent plastic surgeon. The results were classified in;unsatisfactory, satisfactory, good and very good. The average operating time was 6 hours 55 minutes (295 - 650 minutes). Of 58 TMG flaps, 57 (98.3%) were successful. Thrombosis occurred in seven (12%) cases (1 arterial, 6 venous). Flap salvage was successful in six cases and flap failure occurred in one (1.7%) case. The results of 25 patients were graded as good and very good. Three patients showed satisfying and one patient unsatisfying results. Double TMG flaps in unilateral breast reconstruction could lead to good operative results. This method further expands the range of options with autologous tissue in reconstructive breast surgery. © 2015 Wiley Periodicals, Inc. Microsurgery 36:539-545, 2016. © 2015 Wiley Periodicals, Inc.
Facebook Facts: Breast Reconstruction Patient-Reported Outcomes Using Social Media.
Tang, Sherry Y Q; Israel, Jacqueline S; Poore, Samuel O; Afifi, Ahmed M
2018-05-01
Social media are used for information sharing among patients with similar health conditions, and analysis of social media activity could inform clinical decision-making. The aim of this study was to use Facebook to evaluate a cohort of individuals' perceptions of and satisfaction with breast reconstruction. In this observational study, the authors collected and analyzed posts pertaining to autologous and implant-based breast reconstruction from active Facebook groups. Patient satisfaction data were categorized, and a thematic analysis of posts was conducted. Qualitative posts were grouped based on common themes and quantitatively compared using frequency and chi-square analysis. The authors evaluated 500 posts from two Facebook groups. Two hundred sixty-four posts referenced deep inferior epigastric perforator (DIEP) flap reconstruction and 117 were related to implant-based reconstruction. Among individuals referencing DIEP flap reconstruction, 52 percent were satisfied, compared with 20 percent of individuals who referenced satisfaction with implant-based reconstruction (p < 0.0001). Individuals posting about DIEP flaps reported a higher rate of unexpected side effects (p < 0.001) and numbness (p = 0.004). When referencing implant-based reconstruction, individuals reported significantly higher rates of infection, contracture, and implant failure (p < 0.001). Based on the authors' review of social media activity, individuals undergoing DIEP flap breast reconstruction expressed relatively high individual satisfaction despite difficult postoperative recovery. Individuals who referenced implant-based reconstruction mentioned infection and implant failure, leading to high rates of dissatisfaction. Social media appear to provide informational and emotional support to patients. Plastic surgeons can use social media to gather unbiased information of patients' experience to inform clinical conversation and guide clinical practice.
Penile reconstruction with bilateral superficial circumflex iliac artery perforator (SCIP) flaps.
Koshima, Isao; Nanba, Yuzaburo; Nagai, Atsushi; Nakatsuka, Mikiya; Sato, Toshiki; Kuroda, Shigetosi
2006-04-01
The free radial forearm flap is a very common material for penile reconstruction. Its major problems are donor-site morbidity with large depressive scar after skin grafting, urethral fistula due to insufficiency of suture line for the urethra, and need for microvascular anastomosis. A new method using combined bilateral island SCIP flaps for the urethra and penis is developed for gender identity disorder (GID) patients. The advantages of this method are minimal donor-site morbidity with a concealed donor scar, and possible one-stage reconstruction for a longer urethra of 22 cm in length without insufficiency, even for GID female-to-male patients. A disadvantage is poor sensory recovery.
Di Lorenzo, Sara; Zabbia, Giovanni; Corradino, Bartolo; Tripoli, Massimiliano; Pirrello, Roberto; Cordova, Adriana
2017-01-01
Patient: Female, 82 Final Diagnosis: Giant basal cell carcinoma Symptoms: Anemia Medication: — Clinical Procedure: — Specialty: Plastic Surgery Objective: Rare disease Background: Basal cell carcinoma (BCC) greater than 5 cm in diameter is called giant basal cell carcinoma (GBCC), or super giant basal cell carcinoma if it has a diameter larger than 20 cm. Giant BCC only accounts for 0.5% of BCCs and super giant BCC is exceedingly rare. On account of their rarity, there are no established guidelines for GBCC treatment. Case Report: We describe a peculiar case of an 82-year-old woman with a GBCC carcinoma of the lower abdominal wall. The tumor was surgically removed with ipsilateral inguinal lymph nodes and the abdominal wall was reconstructed immediately with a pedicled deep inferior epigastric artery perforator (DIEP) flap. Conclusions: Treatment of giant basal cell carcinoma is often difficult, especially in elderly patients with poor general health and multiple pathologies. The pedicled DIEP flap is rotated to cover the loss of substance without tension, and it is easy to harvest and transfer. This flap allowed a good result without local or systemic complication. We present this report as a reminder of the occasional occurrence of extremely aggressive BCCs. We believe that, especially for rare tumors like these, it is very useful for the entire scientific community to publish these cases and the therapeutic strategies used to treat them. PMID:29199268
Kostopoulos, Epameinondas; Agiannidis, Christos; Konofaos, Petros; Kotsakis, Ioannis; Hatzigianni, Panagiota; Georgopoulos, Gerasimos; Papadatou, Zoe; Konstantinidou, Chara; Champsas, Gregorios; Papadopoulos, Othon; Casoli, Vincent
2018-03-08
Medial canthus is a common area of skin cancer prevalence. Defects in this region represent a challenging reconstructive task. The nasal version of keystone perforator island flap (KPIF) has proven its versatility. The aim of the present study was to expand its utilization in the neighbor medial canthus area. A modified croissant-like KPIF (CKPIF) was used resolving inner convexity-related problems. The presence of procerus in the glabella area, bridging a surface from nasalis up to the frontalis, changed the traditional dissecting flap technique. Thus, the authors introduce the bridge principle, which consists of the indirect transfer of the flap to the defect site through a muscular "bridge" (the procerus). The authors report their experience in medial canthal reconstruction combining a modified KPIF with a new dissecting "principle." From November 2016 to July 2017, a series of patients presenting soft tissue defects of various dimensions in the medial canthus, secondary to tumor extirpation, sustained reconstruction with a CKPIF dissected with the bridge principle. A total of 15 patients were treated with this new technique. Their mean age was 75.3 years. The mean size of the defect was 2.08 cm (length) × 1.5 cm (width). All flaps survived without any sign of venous congestion. A transient epiphora presented in 4 patients (4/15 or 26.6%), which was subsided 2 months later. A new approach following a novel paradigm was introduced to resolve an old problem. Initial outcomes are encouraging. However, longer series are needed to extract definitive and safer conclusion.
Extending the use of the gracilis muscle flap in perineal reconstruction surgery.
Goldie, Stephen J; Almasharqah, Riyadh; Fogg, Quentin A; Anderson, William
2016-08-01
Reconstruction of the perineum is required following oncological resections. Plastic surgical techniques can be used to restore the aesthetics and function of the perineum. The gracilis myocutaneous flap provides a substantial skin paddle, with minimal donor site morbidity. The flap is pedicled on a perforator from the medial circumflex femoral artery, giving it limited reach across the perineum. Tunnelling the flap under the adductor longus muscle may free up more of the arterial pedicle, increasing its reach. On three female cadavers, bilateral gracilis flaps were raised in the standard surgical manner, giving six flaps in total. With the flaps pedicled across the perineum, the distance from the tip of each flap was measured to the anterior superior iliac spine (ASIS). The flaps were then tunnelled under the adductor longus muscle. The distances to the ASIS were measured again. The average pedicle length was greater than 7 cm. Tunnelling the flap under the adductor longus muscle increased the reach by more than 4 cm on average. Cadaveric dissection has shown that tunnelling of the flap in a novel way increase its reach across the perineum. This additional flexibility improves its use clinically and is of benefit to plastic surgeons operating in perineal reconstruction. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Ma, Xianjie; Li, Yang; Li, Weiyang; Liu, Chaohua; Peng, Pai; Song, Baoqiang; Xia, Wensen; Yi, Chenggang; Lu, Kaihua; Su, Yingjun
2017-09-01
The scars of face and scalp caused by burning often show as 1 large facial-scalp scar. The deltopectoral flap was recognized as one of the first choices for the facial scar reconstruction. However, this flap cannot cross the level of zygomatic arch traditionally when it was transferred with pedicle. When the flap reconstructed the facial-scalp scars with expanded random scalp flap, another flap was often needed to reconstruct the remaining temple and forehead scars. The authors reviewed 24 patients of large facial-scalp scars reconstructed by expanded pedicled deltopectoral flap and scalp flap with several technique improvements. The seaming scar between the deltopectoral flap and scalp flap in the temple region formed the new hairline. The technique improvements included ligation of the perforating branches of the transverse cervical artery and thoracoacromial artery when dissecting the pocket, the partial bolster compressive dressing to the distal part of the flap and dividing the pedicle partly as a delaying procedure before dividing the pedicle completely. Good skin compliance, normal contours, and emotional expression were noted. There were complications including expander exposure in 3 patients, stretch marks in 5 patients, flap tip necrosis in 2 patients, and mild postoperative hypertrophic scars in 3 patients. In conclusion, the expanded pedicled deltopectoral flap can enlarge the reconstructive territory in face successfully with the technique improvements. The combination of the expanded pedicled deltopectoral flap and scalp flap is a reliable and excellent reconstructive option for large postburn facial-scalp scars.
Comparison of Three Exit-Area Control Devices on an N.A.C.A. Cowling, Special Report
NASA Technical Reports Server (NTRS)
McHugh, James G.
1940-01-01
Adjustable cowling flaps, an adjustable-length cowling skirt, and a bottom opening with adjustable flap were tested as means of controlling the rate of cooling-air flow through an air-cooled radial-engine cowling. The devices were tested in the NACA 20-foot tunnel on a model wing-nacelle-propeller combination, through an airspeed range of 20 to 80 miles per hour, and with the propeller blade angle set 23 degrees at 0.75 of the tip radius. The resistance of the engine to air flow through the cowling was simulated by a perforated plate. The results indicated that the adjustable cowling flap and the bottom opening with adjustable flap were about equally effective on the basis of pressure drop obtainable and that both were more effective means of increasing the pressure drop through the cowling than the adjustable-length skirt. At conditions of equal cooling-air flow, the net efficiency obtained with the adjustable cowling flaps and the adjustable-length cowling skirt was about 1% greater than the net efficiency obtained with the bottom opening with adjustable flap.
Cifuentes, Ignacio Javier; Dagnino, Bruno Leonardo; Salisbury, María Carolina; Perez, María Eliana; Ortega, Claudia; Maldonado, Daniela
2018-05-01
Dynamic infrared thermography (DIRT) has been used for the preoperative mapping of cutaneous perforators. This technique has shown a positive correlation with intraoperative findings. Our aim was to evaluate the accuracy of perforator mapping with DIRT and augmented reality using a portable projector. For this purpose, three volunteers had both of their anterolateral thighs assessed for the presence and location of cutaneous perforators using DIRT. The obtained image of these "hotspots" was projected back onto the thigh and the presence of Doppler signals within a 10-cm diameter from the midpoint between the lateral patella and the anterior superior iliac spine was assessed using a handheld Doppler device. Hotspots were identified in all six anterolateral thighs and were successfully projected onto the skin. The median number of perforators identified within the area of interest was 5 (range, 3-8) and the median time needed to identify them was 3.5 minutes (range, 3.3-4.0 minutes). Every hotspot was correlated to a Doppler sound signal. In conclusion, augmented reality can be a reliable method for transferring the location of perforators identified by DIRT onto the thigh, facilitating its assessment and yielding a reliable map of potential perforators for flap raising.
Harmonic Scalpel versus electrocautery and surgical clips in head and neck free-flap harvesting.
Dean, Nichole R; Rosenthal, Eben L; Morgan, Bruce A; Magnuson, J Scott; Carroll, William R
2014-06-01
We sought to determine the safety and utility of Harmonic Scalpel-assisted free-flap harvesting as an alternative to a combined electrocautery and surgical clip technique. The medical records of 103 patients undergoing radial forearm free-flap reconstruction (105 free flaps) for head and neck surgical defects between 2006 and 2008 were reviewed. The use of bipolar electrocautery and surgical clips for division of small perforating vessels (n = 53) was compared to ultrasonic energy (Harmonic Scalpel; Ethicon Endo-Surgery, Inc., Cincinnati, Ohio) (n = 52) free-tissue harvesting techniques. Flap-harvesting time was reduced with the use of the Harmonic Scalpel when compared with electrocautery and surgical clip harvest (31.4 vs. 36.9 minutes, respectively; p = 0.06). Two patients who underwent flap harvest with electrocautery and surgical clips developed postoperative donor site hematomas, whereas no donor site complications were noted in the Harmonic Scalpel group. Recipient site complication rates for infection, fistula, and hematoma were similar for both harvesting techniques (p = 0.77). Two flap failures occurred in the clip-assisted radial forearm free-flap harvest group, and none in the Harmonic Scalpel group. Median length of hospitalization was significantly reduced for patients who underwent free-flap harvest with the Harmonic Scalpel when compared with the other technique (7 vs. 8 days; p = 0.01). The Harmonic Scalpel is safe, and its use is feasible for radial forearm free-flap harvest.
Scalise, A; Calamita, R; Tartaglione, C; Bolletta, E; Di Benedetto, G; Pierangeli, M
2016-12-02
Gorlin-Goltz syndrome is mainly characterised by the development of numerous multicentric and relapsing cutaneous basal cell carcinomas (BCCs). A major problem for patients with Gorlin-Goltz syndrome is the large amount of BCCs that can invade the deep underlying structures, especially the face. Here, we describe the case of a 23-year-old male affected by Gorlin-Goltz syndrome. He had recurrent BCCs on a hairless scalp and dorsum since he was 17 years old and underwent four surgical procedures to excise BCCs, including a reconstruction with anteromedial thigh perforator flap. For each of the surgical procedures, a phenotypic study on peripheral blood mononuclear cells using flow cytometry was performed on the same day of surgery, and on days 7, 14 and 21 after surgery. The role of the tumour-specific cytolytic immune response as a potential future treatment of syndromic BCCs and its trend in relation to surgical ablation of large portions of tumour tissue was examined, and the cosmetic and therapeutic results are shown.
Schoeller, Thomas; Huemer, Georg M; Wechselberger, Gottfried
2008-07-01
The transverse musculocutaneous gracilis (TMG) flap has received little attention in the literature as a valuable alternative source of donor tissue in the setting of breast reconstruction. The authors give an in-depth review of their experience with breast reconstruction using the TMG flap. A retrospective review of 111 patients treated with a TMG flap for breast reconstruction in an immediate or a delayed setting between August of 2002 and July of 2007 was undertaken. Of these, 26 patients underwent bilateral reconstruction and 68 underwent unilateral reconstruction, and 17 patients underwent reconstruction unilaterally with a double TMG flap. Patient age ranged between 24 and 65 years (mean, 37 years). Twelve patients had to be taken back to the operating room because of flap-related problems and nine patients underwent successful revision microsurgically, resulting in three complete flap losses in a series of 111 patients with 154 transplanted TMG flaps. Partial flap loss was encountered in two patients, whereas fat tissue necrosis was managed conservatively in six patients. Donor-site morbidity was an advantage of this flap, with a concealed scar and minimal contour irregularities of the thigh, even in unilateral harvest. Complications included delayed wound healing (n = 10), hematoma (n = 5), and transient sensory deficit over the posterior thigh (n = 49). The TMG flap is more than an alternative to the deep inferior epigastric perforator (DIEP) flap in microsurgical breast reconstruction in selected patients. In certain indications, such as bilateral reconstructions, it possibly surpasses the DIEP flap because of a better concealed donor scar and easier harvest.
Principles of definitive soft tissue coverage with flaps.
Levin, L Scott
2008-01-01
Despite the emergence of negative pressure wound therapy with reticulated open cell foam (NPWT/ROCF) as delivered by V.A.C.(R) Therapy (KCI, San Antonio, TX) for orthopaedic trauma, vascularized tissue transfer whether it be pedicle, free, or tissue transfer using the operating microscope or as an island, remains the mainstay of soft tissue reconstruction for orthopaedic traumatology. The critisism of microvascular procedures has been that they are lengthy, costly, and required technical expertise to perform. While technical skills are required, microsurgical care has evolved into a routine operation with high degrees of success in experienced hand. The problem that still remains is access to surgeons who are interested in soft tissue reconstruction and can perform definitive coverage with flaps. There is a need in the orthopaedic community to solve the problem of lack of flap surgeons and as a result, NPWT/ROCF has been touted as the answer to flap reconstruction. NPWT/ROCF is an important addition to soft tissue reconstruction but it serves as a bridge rather than definitive coverage in many hands. Just as wound technology is evolving with tissue substitutes, growth factors and NPWT/ROCF flaps technology continues to advance with new perforator flaps and local regional flaps, particularly the sural flap, coming on line as mainstays of soft tissue reconstruction.
Availability of the lateral calcaneal region as a donor site of free flaps.
Cho, Seung Woo; Park, Ji Ung; Kwon, Sung Tack
2017-09-01
Various methods have been used for the coverage of soft-tissue defects, such as local and free flaps, as well as perforator flaps performed using even supermicrosurgery. However, the techniques have some limitations regarding flap size and location when used to reconstruct small defects. We introduced the lateral calcaneal region as a donor site for free flaps in order to overcome these disadvantages and presented the results from a series of cases. A retrospective chart review was performed on 10 patients with small soft-tissue defects who underwent reconstruction with a lateral calcaneal free flap between January 2011 and May 2014. The reconstruction was performed on the defects at medial and lateral plantar area, dorsum of the foot, great toes and preauricular area. The size of the flaps ranged from 2.5 × 2.5 cm to 4.5 × 4.5 cm. The flaps exhibited complete survival in five cases. Partial necrosis occurred in three cases, two cases healed with secondary intention, and one case required a skin graft. The donor sites were treated with skin grafts and healed completely, with no complications. Lateral calcaneal free flaps have several advantages, such as anatomically constant pedicles, a pliable and thin texture, and the ability to be used as sensory flaps. They therefore represent an alternative option when conventional local or free flaps are not suitable, especially in cases of small defects. © 2016 Wiley Periodicals, Inc. Microsurgery 37:494-501, 2017. © 2016 Wiley Periodicals, Inc.
Lower Extremity Reconstruction with Free Gracilis Flaps
Nicoson, Michael C; Parikh, Rajiv P; Tung, Thomas H
2017-01-01
Background There have been significant advancements in lower extremity reconstruction over the last several decades, and the plastic surgeon’s armamentarium has grown to include free muscle and fasciocutaneous flaps along with local perforator and propeller flaps. While we have found a use for a variety of techniques for lower extremity reconstruction, the free gracilis has been our workhorse flap due to the ease of harvest, reliability, and low donor site morbidity. Methods This is a retrospective review of a single surgeon’s series of free gracilis flaps utilized for lower extremity reconstruction. Demographic information, comorbidities, outcomes and secondary procedures were analyzed. Results We identified 24 free gracilis flaps. The duration from injury to free flap coverage was 7 days or less in 6 patients, 8–30 days in 11 patients, 31–90 days in 4 patients, and > 90 days in 3 patients. There were 22 (92%) successful flaps and an overall limb salvage rate of 92%. There was one partial flap loss. Two flaps underwent incision and drainage in the operating room for infection. Two patients developed donor site hematomas. Four patients underwent secondary procedures for contouring. Our subset of pediatric patients had 100% flap survival and no secondary procedures at a mean 30 month follow up. Conclusions This study demonstrates the utility of the free gracilis flap in reconstruction of small to medium sized defects of the lower extremity. This flap has a high success rate and low donor site morbidity. Atrophy of the denervated muscle over time allows for good shoe fit, often obviating the need for secondary contouring procedures. PMID:28024305
Yano, Kenji; Taminato, Mifue; Nomori, Michiko; Hosokawa, Ko
2017-01-01
Background: Autologous breast reconstruction can be performed for breasts with ptosis to a certain extent, but if patients desire to correct ptosis, mastopexy of the contralateral breast is indicated. However, accurate prediction of post-mastopexy breast shape is difficult to make, and symmetrical breast reconstruction requires certain experience. We have previously reported the use of three-dimensional (3D) imaging and printing technologies in deep inferior epigastric artery perforator (DIEP) flap breast reconstruction. In the present study, these technologies were applied to the reconstruction of breasts with ptosis. Methods: Eight breast cancer patients with ptotic breasts underwent two-stage unilateral DIEP flap breast reconstruction. In the initial surgery, tissue expander (TE) placement and contralateral mastopexy are performed simultaneously. Four to six months later, 3D bilateral breast imaging is performed after confirming that the shape of the contralateral breast (post-mastopexy) is somewhat stabilized, and a 3D-printed breast mold is created based on the mirror image of the shape of the contralateral breast acquired using analytical software. Then, DIEP flap surgery is performed, where the breast mold is used to determine the required flap volume and to shape the breast mound. Results: All flaps were engrafted without any major perioperative complications during both the initial and DIEP flap surgeries. Objective assessment of cosmetic outcome revealed that good breast symmetry was achieved in all cases. Conclusions: The method described here may allow even inexperienced surgeons to achieve reconstruction of symmetrical, non-ptotic breasts with ease and in a short time. While the requirement of two surgeries is a potential disadvantage, our method will be particularly useful in cases involving TEs, i.e., delayed reconstruction or immediate reconstruction involving significant skin resection. PMID:29184728
Wolter, Andreas; Scholz, Till; Pluto, Naja; Diedrichson, Jens; Arens-Landwehr, Andreas; Liebau, Jutta
2017-12-01
Mastopexy in massive weight loss patients is challenging. The breast mound is often unstable and deflated, with a loose inelastic skin envelope. It has become apparent that mammaplasty techniques in these cases should rely more on glandular recontouring rather than on the skin envelope for shaping. Published methods include plication, suspension and autoaugmentation. The residual local tissue (glandular breast tissue, fat tissue, dermoglandular fat flap) is utilised to its full extent in order to reshape a form-stable breast with full upper pole projection. The evolution of a technique is presented. In this study we retrospectively analysed 68 massive weight loss patients who underwent an extended Ribeiro technique with a superomedial pedicle mastopexy and suspension by an inferior dermoglandular flap. The current procedure involves incorporating the lateral intercostal artery perforator flap (LICAP flap) and medial breast pillar additionally to the inferior dermoglandular Ribeiro flap. This essentially autoaugments the upper pole by creating an "autoprosthesis", narrows the widened breast, and redefines the inframammary fold. The outcome parameters complication rate, patient satisfaction with the aesthetic result, nipple sensibility and surgical revision rate were obtained. From 01/2011 to 12/2016, we performed 136 autoaugmentation mastopexies. The average age was 41.2 years, average body mass index (BMI) was 27,1 kg/m 2 , average weight loss was 54.3 kg, average sternal notch-NAC distance was 32.3 cm, average operation time was 109 minutes. In 12 breasts, a free-nipple graft was necessary. The complication rate was 5.1 %, surgical revision rate was 17.6 %. 95 % of the patients were "very satisfied" or "satisfied" with the aesthetic result. Nipple sensibility was rated as "very good" or "good" by 85 % of patients. Modification of the Ribeiro technique by using the medial and lateral breast pillar (LICAP flap) allows autoaugmentation of the upper pole. Parenchymal shaping through plication and suspension of the breast mound should improve breast shape over time, with the aim of reducing the incidence of recurrent ptosis. The presented technique is a reproducible and reliable method with a low complication rate. Georg Thieme Verlag KG Stuttgart · New York.
Ni, Song; Zhu, Yiming; Li, Dezhi; Liu, Jie; An, Changming; Zhang, Bin; Liu, Shaoyan
2015-11-01
To discuss the management of vascular crisis of free flaps after reconstruction of head and neck defects caused by tumor resection. A total of 259 cases of free flap reconstruction performed in the Cancer Hospital of Chinese Academy of Medical Sciences from 2010 to 2013 were retrospectively analyzed, including 89 cases of anterolateral thigh flaps, 48 cases of radial forearm flaps, 46 free fibula flaps, 5 cases of inferior epigastric artery perforator flaps, 5 cases of free latissimus dorsi flaps, one case of lateral arm flap, and one case of medial femoral flap. The surveillance frequency of free flaps was q1h on post-operative day (POD) 1, q2h on POD 2 and 3, and q4h after POD 3. Vascular crises were reviewed for analysis. The incidence rate of vascular crisis was 8.1% (21/259), with 15 males and 6 females. The average age was 54.8 years old (17-68), and the average time of vascular crisis was 100.8 h post-operation (3-432). There were 7 cases of free jejunum flaps and 14 dermal free flaps. Seven of these 21 cases with vascular crisis were rescued by surgery. The success rate of salvage surgery within 72 hours from the primary operation was 54.5% (6/11), significantly higher than that of salvage surgery performed later than 72 hours from primary operation (10.0%, 1/10, P=0.043). There were 14 cases of flap necrosis, two of which died of local infection. Early detection of vascular crisis can effectively improve the success rate of salvage, so as to avoid the serious consequences caused by free flap necrosis.
Bigdeli, Amir Khosrow; Gazyakan, Emre; Schmidt, Volker Juergen; Hernekamp, Frederick Jochen; Harhaus, Leila; Henzler, Thomas; Kremer, Thomas; Kneser, Ulrich; Hirche, Christoph
2016-06-01
Near-infrared indocyanine green video angiography (ICG-NIR-VA) has been introduced for free-flap surgery and may provide intraoperative flap designing as well as postoperative monitoring. Nevertheless, the technique has not been established in clinical routine because of controversy over benefits. Improved technical features of the novel Visionsense ICG-NIR-VA surgery system are promising to revisit the field of application. It features a unique real-time fusion image of simultaneous NIR and white light visualization, with highlighted perfusion, including a color-coded perfusion flow scale for optimized anatomical understanding. In a feasibility study, the Visionsense ICG-NIR-VA system was applied during 10 free-flap surgeries in 8 patients at our center. Indications included anterior lateral thigh (ALT) flap (n = 4), latissimus dorsi muscle flap (n = 1), tensor fascia latae flap (n = 1), and two bilateral deep inferior epigastric artery perforator flaps (n = 4). The system was used intraoperatively and postoperatively to investigate its impact on surgical decision making and to observe perfusion patterns correlated to clinical monitoring. Visionsense ICG-NIR-VA aided assessing free-flap design and perfusion patterns in all cases and correlated with clinical observations. Additional interventions were performed in 2 cases (22%). One venous anastomosis was revised, and 1 flap was redesigned. Indicated by ICG-NIR-VA, 1 ALT flap developed partial flap necrosis (11%). The Visionsense ICG-NIR-VA system allowed a virtual view of flap perfusion anatomy by fusion imaging in real-time. The system improved decision making for flap design and surgical decisions. Clinical and ICG-NIR-VA parameters correlated. Its future implementation may aid in improving outcomes for free-flap surgery, but additional experience is needed to define its final role. © The Author(s) 2015.
Repair of cocaine-related oronasal fistula with forearm radial free flap.
Colletti, Giacomo; Allevi, Fabiana; Valassina, Davide; Bertossi, Dario; Biglioli, Federico
2013-01-01
Cocaine snorting may cause significant local ischemic necrosis and the destruction of nasal and midfacial bones and soft tissues, leading to the development of a syndrome called cocaine-induced midline destructive lesion. A review of the English-language literature reveals only a few articles describing the treatment of hard and/or soft palatal perforation related to cocaine inhalation. Described here are 4 patients with a history of cocaine abuse showing palatal lesions. From 2010 to 2013, a total of 4 patients affected by cocaine-related midline destructive lesions were referred to our department. They all presented signs of a cocaine-induced midline destructive lesion. They showed wide midfacial destruction involving the nasal septum as well as the hard and soft palates causing an ample oronasal communication. In 3 patients, oronasal communication has been treated successfully using a personal technique based on a partially de-epithelialized forearm free flap. The fourth patient had been treated only with local debridement because, when she came to our attention, her abusive habits were still unsolved. Different surgical options have been reported such as local, regional, and free flaps for hard and soft palate reconstruction. However, because of an unpredictable vascularization of the palatal tissues and owing to the scarceness of the local soft tissues, local flaps are at high risk for partial and complete failure. The transfer of free vascularized tissue, however, seems to be the most reliable and logical solution for medium- to large-sized fistulas. Among the various free flaps, we choose the radial forearm type because of the pedicle length and the flap thickness.
Propeller Flaps and Its Outcomes - A Prospective Study of 15 Cases Over Two-years.
K T, Ramesha; J, Vijay; M, Shankarappa
2014-01-01
Cover flaps are needed in management of any bodily defect involving bone, tendon, nerve & vessels. The major objective of a plastic surgeon, facing a complex soft-tissue defect, is to replace "like with like" tissues at minimal donor site "cost" and with maximal accuracy & efficacy. To study the "Propeller Flaps" utility in reconstructive surgeries, evaluate its planning and complications involving donor site morbidity. The prospective study was conducted on 15 cases (11 males/4 females) of propeller flaps during the period of two years (2010-12) in Department of Plastic Surgery and Burns, Bangalore Medical College and Research Institute (BMCRI), Karnataka, India. The propeller flaps were performed in cases with defects due to any cause. Cases with Peripheral Vascular Disease (PVD). Flaps were performed and details recorded. Overall results revealed problem resolution in 87% cases (13 cases). Comprehensive description of each flap type and its related cases are given in the table. It has been categorically found that there were 2 flap partial losses. Partial necrosis has been reported in heavy-smoker patients. This current study clearly justifies that careful application, optimal designing & judicious scientific application of local perforator flaps for lower-limb wounds including rest of the body is successful in many aspects providing high-quality reconstruction ensuring minimal morbidity. It is cost-effective as well as time-saving.
Application of DIRI dynamic infrared imaging in reconstructive surgery
NASA Astrophysics Data System (ADS)
Pawlowski, Marek; Wang, Chengpu; Jin, Feng; Salvitti, Matthew; Tenorio, Xavier
2006-04-01
We have developed the BioScanIR System based on QWIP (Quantum Well Infrared Photodetector). Data collected by this sensor are processed using the DIRI (Dynamic Infrared Imaging) algorithms. The combination of DIRI data processing methods with the unique characteristics of the QWIP sensor permit the creation of a new imaging modality capable of detecting minute changes in temperature at the surface of the tissue and organs associated with blood perfusion due to certain diseases such as cancer, vascular disease and diabetes. The BioScanIR System has been successfully applied in reconstructive surgery to localize donor flap feeding vessels (perforators) during the pre-surgical planning stage. The device is also used in post-surgical monitoring of skin flap perfusion. Since the BioScanIR is mobile; it can be moved to the bedside for such monitoring. In comparison to other modalities, the BioScanIR can localize perforators in a single, 20 seconds scan with definitive results available in minutes. The algorithms used include (FFT) Fast Fourier Transformation, motion artifact correction, spectral analysis and thermal image scaling. The BioScanIR is completely non-invasive and non-toxic, requires no exogenous contrast agents and is free of ionizing radiation. In addition to reconstructive surgery applications, the BioScanIR has shown promise as a useful functional imaging modality in neurosurgery, drug discovery in pre-clinical animal models, wound healing and peripheral vascular disease management.
Rozen, Warren Matthew; Chowdhry, Muhammad; Band, Bassam; Ramakrishnan, Venkat V.; Griffiths, Matthew
2016-01-01
Background The approach and operative techniques associated with breast reconstruction have steadily been refined since its inception, with abdominal perforator-based flaps becoming the gold standard reconstructive option for women undergoing breast cancer surgery. The current study comprises a cohort of 632 patients, in whom specific operative times are recorded by a blinded observer, and aims to address the potential benefits seen with the use of computer tomography (CT) scanning preoperatively on operative outcomes, complications and surgical times. Methods A prospectively recorded, retrospective review was undertaken of patients undergoing autologous breast reconstruction with a DIEP flap at the St Andrews Centre over a 4-year period from 2010 to 2014. Computed tomography angiography (CTA) scanning of patients began in September 2012 and thus 2 time periods were compared: 2 years prior to the use of CTA scans and 2 years afterwards. For all patients, key variables were collected including patient demographics, operative times, flap harvest time, pedicle length, surgeon experience and complications. Results In group 1, comprising patients within the period prior to CTA scans, 265 patients underwent 312 flaps; whilst in group 2, the immediately following 2 years, 275 patients had 320 flaps. The use of preoperative CTA scans demonstrated a significant reduction in flap harvest time of 13 minutes (P<0.013). This significant time saving was seen in all flap modifications: unilateral, bilateral and bipedicled DIEP flaps. The greatest time saving was seen in bipedicle flaps, with a 35-minute time saving. The return to theatre rate significantly dropped from 11.2% to 6.9% following the use of CTA scans, but there was no difference in the total failure rate. Conclusions The study has demonstrated both a benefit to flap harvest time as well as overall operative times when using preoperative CTA. The use of CTA was associated with a significant reduction in complications requiring a return to theatre in the immediate postoperative period. Modern scanners and techniques can reduce the level of ionising radiation, facilitating patients being able to benefit from the advantages that this preoperative planning can convey. PMID:27047777
Does the Latissimus dorsi insert on the iliac crest in man? Anatomic and ontogenic study.
Ben Hadj Yahia, Sihem; Vacher, Christian
2011-11-01
The Latissimus dorsi muscle is usually considered as inserted on the iliac crest, but it is separated from it by the thoracolumbar fascia. In our experience based on the harvesting of pedicled Latissimus dorsi flaps to cover cervicofacial loss of substances, we have found that in some cases, the muscular fibers of the anterior border of the muscle are directly inserted on the iliac crest. In these cases, the harvesting of the flap could be more distal. To determine whether this direct muscular insertion is frequent or not, we performed dissections on 30 fresh cadavers of the lower insertion of the Latissimus dorsi muscle, and 6 dissections of human fetuses to study the ontogeny of these insertions. The Latissimus dorsi muscle presented direct muscular insertions on the iliac crest in 13.33% of cases. The fetal dissections showed that before 30 weeks of development, the anterior part of the muscle was directly inserted on the iliac crest, and after it was separated from it by the thoracolumbar fascia. Although the harvesting of the Latissimus dorsi in continuity with the thoracolumbar fascia has been described in pedicled flaps, it is usually considered that it is impossible to harvest Latissimus dorsi musculocutaneous flaps in contact with the iliac crest, because there are no perforating vessels from the thoracolumbar fascia to the skin. According to our results, in some cases, it could be possible to harvest a pedicled musculo-cutaneous LD flap more distal that it is usually described.
Cifuentes, Ignacio Javier; Dagnino, Bruno Leonardo; Salisbury, María Carolina; Perez, María Eliana; Ortega, Claudia; Maldonado, Daniela
2018-01-01
Dynamic infrared thermography (DIRT) has been used for the preoperative mapping of cutaneous perforators. This technique has shown a positive correlation with intraoperative findings. Our aim was to evaluate the accuracy of perforator mapping with DIRT and augmented reality using a portable projector. For this purpose, three volunteers had both of their anterolateral thighs assessed for the presence and location of cutaneous perforators using DIRT. The obtained image of these “hotspots” was projected back onto the thigh and the presence of Doppler signals within a 10-cm diameter from the midpoint between the lateral patella and the anterior superior iliac spine was assessed using a handheld Doppler device. Hotspots were identified in all six anterolateral thighs and were successfully projected onto the skin. The median number of perforators identified within the area of interest was 5 (range, 3–8) and the median time needed to identify them was 3.5 minutes (range, 3.3–4.0 minutes). Every hotspot was correlated to a Doppler sound signal. In conclusion, augmented reality can be a reliable method for transferring the location of perforators identified by DIRT onto the thigh, facilitating its assessment and yielding a reliable map of potential perforators for flap raising. PMID:29788686
Jiang, Chunjing; Lin, Ping; Fu, Xiaoyan; Shu, Jiner; Li, Huimin; Hu, Xiaogang; He, Jianrong; Ding, Mingxing
2016-08-01
Flap transfer is increasingly used for repairing limb defects secondary to trauma or tumor, and appropriate preoperative planning plays a critical role. The present study aimed to examine the use of three-dimensional (3D) contrast-enhanced magnetic resonance angiography (CE-MRA) in evaluating the blood supply distribution and perforating branch pattern of anterolateral thigh (ALT) flaps. Bilateral donor lower limbs were scanned in 68 patients (136 limbs) using a Siemens Avanto 1.5 T magnetic resonance imaging scanner with a 3D fast low-angle shot sequence, following the thin-slab maximum intensity projection (TS-MIP) technique. The lateral femoral circumflex artery (LFCA) was visualized in all patients: 101 limbs (101/136, 74.3%) were type I; 20 limbs (20/136, 14.7%) were type II; 3 limbs (3/136, 2.2%) were type III; and 12 limbs (12/136, 8.8%) were type IV. Tertiary branches were identified in 94 limbs (94/136, 69.1%). Donor flaps were outlined according to MRA TS-MIP findings in 4 patients. All flaps survived uneventfully following the transfer. In donor flap outlining, 3D CE-MRA with the TS-MIP technique allowed an accurate, direct visualization of the branching pattern and distribution profile of the LFCA supplying the ALT flap.
Venous coupler use for free-flap breast reconstructions: specific analyses of TMG and DIEP flaps.
Bodin, Frédéric; Brunetti, Stefania; Dissaux, Caroline; Erik, A Sauleau; Facca, Sybille; Bruant-Rodier, Catherine; Liverneaux, Philippe
2015-05-01
The purpose of this report was to present the results of comparisons of anastomotic data and flap complications in the use of venous coupler in breast reconstruction with the transverse musculocutaneous gracilis (TMG) flap and the deep inferior epigastric perforator (DIEP) flap. Over a three-year period, 95 patients suffering from breast cancer were treated with mastectomy and breast reconstruction using free flaps. We performed 121 mechanical venous anastomoses for 105 flap procedures (80 DIEP and 25 TMG). The coupler size, anastomotic duration, number of anastomoses and postoperative complications were assessed for the entire series. The coupling device was perfectly suitable for all end-to-end anastomoses between the vein(s) of the flap and the internal mammary vein(s). No venous thrombosis occurred. The mean anastomotic time did not significantly differ between the DIEP (330 seconds) and TMG flap procedures (352 seconds) (P = 0.069). Additionally, there were no differences in coupling time observed following a comparison of seven coupler sizes (P = 0.066). The mean coupler size used during the TMG flap procedure was smaller than that used with the DIEP (2.4 mm versus 2.8 mm) (P < 0.001). The mean size was also smaller when double venous anastomoses were required compared to single anastomosis (2.4 mm versus 2.9 mm) (P < 0.001). The double branching was more frequent with the TMG flap (28%) than with the DIEP flap (11%). The coupler size used was smaller for the TMG procedure and when double venous anastomosis was performed. Additionally, anastomotic time was not affected by the flap type or coupler size used or by anastomosis number. © 2014 Wiley Periodicals, Inc.
A New Technique for Coronaplasty in Penile Reconstruction.
Sommeling, Casper E; De Wolf, Edward J; Salim, Ali; Monstrey, Stan; Opsomer, Dries; Claes, Karel; D'Arpa, Salvatore
2018-06-01
The coronaplasty is an important step of the phalloplasty procedure as it creates a prominent coronal ridge and a constricted coronal sulcus, resulting in the transformation of a regular skin flap into a flap resembling a circumcised penis. The aim of this article is to describe our new coronaplasty technique that exploits opposing contracting forces of 2 different skin grafts to hold the shape of a thick, distally based skin flap, resulting in a natural looking neo-phallus. A distally based flap is raised at the junction of the middle and distal thirds of the neo-phallus. The dissection continues until adequate mobilization is obtained, so the flap can stand almost perpendicular to the axis of the shaft. 2 separate full-thickness skin grafts are harvested and placed: the first at the raw undersurface of the flap, the second at the flap's donor site. To make the sulcus deeper and to define the ridge, the lower part of the graft placed on the undersurface of the distal flap is sutured with tacking sutures. Depending on the type of flap used this procedure can be done during the phalloplasty procedure itself (axial flaps) or at least 1 week later (perforator flaps). The new technique that we developed shows a more distinct coronal sulcus and coronal ridge, long-lasting results, and a more aesthetically pleasing and natural-appearing glans penis. The harvested distal flap is progressively thicker and not folded, resulting in a more naturally looking ridge. The donor site is deeper than other techniques, creating a well-defined sulcus. By using 2 skin grafts the opposing force vectors increase the projection of the ridge and the deepness of the sulcus. This technique results in a more prominent glans penis and is an important step in creating an almost naturally looking neo-phallus. This procedure can be applied to all different kind of flaps used for phalloplasty, both in an immediate or delayed fashion. As grafts are used, partial or complete graft lost can appear. Furthermore, attention must be paid not to incise the distal flap too deep so vascularity to the distal part of the flap will not be impaired. A continuous search to optimize the aesthetic outcome of the phalloplasty procedure is necessary and with this new coronaplasty technique we hope to raise attention and take another step toward creating "the real thing." Sommeling CE, De Wolf EJ, Salim A, et al. A New Technique for Coronaplasty in Penile Reconstruction. J Sex Med 2018;15:920-923. Copyright © 2018 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.
Breast Reinnervation: DIEP Neurotization Using the Third Anterior Intercostal Nerve
Menn, Zachary K.; Eldor, Liron; Kaufman, Yoav; Dellon, A. Lee
2013-01-01
Background: The purpose of this article is to evaluate a new method of DIEP flap neurotization using a reliably located recipient nerve. We hypothesize that neurotization by this method (with either nerve conduit or direct nerve coaptation) will have a positive effect on sensory recovery. Methods: Fifty-seven deep inferior epigastric perforator (DIEP) flaps were performed on 35 patients. Neurotizations were performed to the third anterior intercostal nerve by directly coapting the flap donor nerve or coapting with a nerve conduit. Nine nonneurotized DIEP flaps served as controls and received no attempted neurotization. All patients were tested for breast sensibility in 9 areas of the flap skin-island and adjacent postmastectomy skin. Testing occurred at an average of 111 weeks (23–309) postoperatively. Results: At a mean of 111 weeks after breast reconstruction, neurotization of the DIEP flap resulted in recovery of sensibility that was statistically significantly better (lower threshold) in the flap skin (P < 0.01) and statistically significantly better than in the native mastectomy skin into which the DIEP flap was inserted (P < 0.01). Sensibility recovered in DIEP flaps neurotized using the nerve conduit was significantly better (lower threshold) than that in the corresponding areas of the DIEP flaps neurotized by direct coaptation (P < 0.01). Conclusion: DIEP flap neurotization using the third anterior intercostal nerve is an effective technique to provide a significant increase in sensory recovery for breast reconstruction patients, while adding minimal surgical time. Additionally, the use of a nerve conduit produces increased sensory recovery when compared direct coaptation. PMID:25289267
Prophylactic flap coverage and the incidence of bronchopleural fistulae after pneumonectomy
Llewellyn-Bennett, Rebecca; Wotton, Robin; West, Douglas
2013-01-01
A best evidence topic in thoracic surgery was written according to a structured protocol. The question addressed was ‘In pneumonectomy patients, is buttressing the bronchial stump associated with a reduced incidence of bronchopleural fistula?’. Fifty-seven papers were found using the reported search, of which 12 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. One prospective randomized controlled trial was identified, which found significantly lower rates of bronchopleural fistula and empyema after pneumonectomy with the use of pedicled intercostal flap buttressing. Intercostal muscle flaps and pericardial flaps have been used in case series of high-risk patients, e.g. those with neoadjuvant therapy or extended resections, with low rates of subsequent bronchopleural fistulae. There is the least-reported evidence for thoracodorsal artery perforator and omental flaps. There is relatively little published evidence beyond the single randomized trial identified, with only a few comparison studies to guide clinicians. We conclude that there is evidence for flap buttressing in reducing the risk of bronchopleural fistulae after pneumonectomy in diabetic patients. Flap coverage in other high-risk situations, such as extrapleural or completion pneumonectomy, has been reported in case series with good results. Of the reported techniques, the evidence is strongest for the pedicled inter-costal flap. PMID:23357525
Kwon, Kye Yoon; Ji, Yong Woo; Lee, Jeihoon; Kim, Eung Kweon
2016-07-18
Surgical lifting and scraping is a well-known treatment for epithelial ingrowth, but treatment for epithelial ingrowth on the centrally perforated laser in situ keratomileusis (LASIK) flap has not been well studied. We present a patient who had epithelial ingrowth to the backside of the flap through a central LASIK flap laceration with a stellate shape. The patient had undergone uncomplicated bilateral LASIK surgery 3 years before the trauma. Because the epithelial ingrowth was suspected during the first visit 2 weeks after trauma, and definite epithelial ingrowth was noted during the additional 2 week observation period, the ingrown epithelial tissue was removed mechanically with a number 15 blade after lifting of the flap 4 weeks after the trauma. An amniotic membrane overlay was applied over the cornea and was sutured tightly to the episclera to firmly press down the flap to the remaining posterior stroma, to prevent growth of the epithelium again to the backside of the flap. At the last follow-up visit, 5 months after surgery, the patient's visual acuity remained stabilized with no sign of recurrent epithelial ingrowth. These results showed that an amniotic membrane patch can be a useful adjuvant in the treatment of epithelial ingrowth, even on the central stellate laceration of the LASIK flap over the visual axis.
Duan, Jiazhang; He, Xiaoqing; Xu, Yongqing; Fan, Xinyu; Luo, Haotian; Wang, Teng; Dong, Kaixuan; Yu, Kaifu
2015-07-01
To investigate the effectiveness of digital technology in repairing wounds of the hand and foot with anterolateral thigh flap. Between September 2013 and September 2014, 16 cases of wounds of the hand and foot were treated with the anterolateral thigh flap. There were 10 males and 6 females, with an average age of 31 years (range, 20-52 years). The causes included traffic accident injury in 8 cases, crushing injury by machine in 6 cases, burning injury in 1 case, and animal biting injury in 1 case. The locations of soft tissue defect were the dorsum of the foot in 5 cases, the ankle in 4 cases, the planta pedis in 1 case, and the hand and forearm in 6 cases. The time was 2 hours to 45 days from injury to hospitalization (mean, 14.3 days). All defects were associated with exposure of bone and tendon. The size of wound was from 9.0 cmx4.0 cm to 29.0 cmx8.5 cm. CT angiography (CTA) was performed before operation, and the appropriate perforator as well as the donor site was selected. Then the Mimics l5.0 software was used to reconstruct the data of CTA so as to locate the main perforators, design the three-dimensional models of the anterolateral thigh flap, and simulate operation. The flap was obtained according to preoperative plan during operation. The size of flaps varied from 11 cm x 5 cm to 31 cm x 10 cm. The donor sites were sutured directly in 14 cases and were repaired by free skin graft in 2 cases. The lateral femoral circumflex artery identified by Mimics l5.0 software before operation, as well as the starting position of its descending branch, the blood vessel diameter at start site, vascular distribution, the maximum cutting length of the vascular pedicle were consistent with the actual observation during operation. All flaps were harvested and were used to repair defect smoothly. Vascular crisis occurred in 1 flap after operation, and the other flaps survived successfully. The wounds and the incisions obtained healing by first intention, and grafted skin survived completely. All cases were followed up 6-17 months (mean, 9 months). Fifteen flaps had good shape; but a second- stage operation was performed to make the flap thinner in 1 case. At last follow-up, the results were excellent in 3 cases, good in 2 cases, and fair in 1 case according to total active motion (TAM) in 6 cases of hand and forearm injury; the results were excellent in 5 cases, good in 3 cases, and fair in 2 cases according to American Orthopaedic Foot and Ankle Society (AOFAS) in 10 cases of foot injury. The total excellent and good rate was 81.25%. The preoperative individualization design of the flap can be realized through CTA digital technology and Mimics 15.0 software; it can reduce the operation risk.
Schirmer, Steffen; Ritter, Ralf-Gerhard; Fansa, Hisham
2013-01-01
Introduction Diabetic foot ulcers occur in approximately 2,5% of patients suffering from diabetes and may lead to major infections and amputation. Such ulcers are responsible for a prolonged period of hospitalization and co- morbidities caused by infected diabetic foot ulcers. Small, superficial ulcers can be treated by special conservative means. However, exposed bones or tendons require surgical intervention in order to prevent osteomyelitis. In many cases reconstructive surgery is necessary, sometimes in combination with revascularization of the foot. There are studies on non surgical treatment of the diabetic foot ulcer. Most of them include patients, classified Wagner 1-2 without infection. Patients presenting Wagner 3D and 4D however are at a higher risk of amputation. The evolution of microsurgery has extended the possibilities of limb salvage. Perforator based flaps can minimize the donorsite morbidity. Patients and Methods 41 patients were treated with free tissue transfer for diabetic foot syndrome and chronic defects. 44 microvascular flaps were needed. The average age of patients was 64.3 years. 18 patients needed revascularization. 3 patients needed 2 microvascular flaps. In 6 cases supramicrosurgical technique was used. Results There were 2 flap losses leading to amputation. 4 other patients required amputation within 6 months postoperatively due to severe infection or bypass failure. Another 4 patients died within one year after reconstruction. The remaining patients were ambulated. Discussion Large defects of the foot can be treated by free microvascular myocutaneous or fasciocutaneous tissue transfer. If however, small defects, exposing bones or tendons, are not eligible for local flaps, small free microvascular flaps can be applied. These flaps cause a very low donor site morbidity. Arterialized venous flaps are another option for defect closure. Amputation means reduction of quality of life and can lead to an increased mortality postoperatively. PMID:24058622
Seidenstuecker, K; Legler, U; Munder, B; Andree, C; Mahajan, A; Witzel, C
2016-05-01
Currently, autologous breast reconstruction with a free tissue transfer from the lower abdomen is considered to be a safe method that provides a stable long-term solution. The DIEP-flap and the ms-2-TRAM-flap reconstructions have helped reduce donor site morbidity. In order to assess the potential differences between these techniques, we carried out myosonographic evaluations that assessed the muscle dynamics pre- and post-operatively. In addition to investigating the properties of the rectus abdominis muscle post-operatively, this prospective study also allowed us to analyse the muscle preoperatively and to investigate the prospects for harvesting a DIEP-flap as opposed to a TRAM-flap. Sixty patients underwent breast reconstruction with 71 (11 bilateral) free abdominal wall flaps (DIEP-: n = 48; ms-2-TRAM-flap: n = 23). Myosonographic examinations were performed preoperatively and at 3 and 6 months post-operatively. The thickness of the muscle at relaxation and maximum contraction and the difference between the muscle thickness measured at the two states were measured. A general-linear-model (GLM) was used for statistical analysis. The main variable was the surgical method, and the co-variables included BMI and patient age. The decision on whether to harvest a DIEP- or ms-2-TRAM-flap was made intra-operatively and based on the dominant perforator. It shows that the patients who underwent breast reconstruction with a DIEP-flap had significantly better muscle function (p < 0.05) in the follow-up. In addition, the analysis revealed that better muscle function before surgery made it more likely that a patient would undergo a DIEP-flap-reconstruction successfully. Patient age also had a highly significant effect on muscle recovery (p < 0.0005). This prospective study used a dynamic ultrasound evaluation of the abdominal wall and showed that the DIEP-flap significantly reduces donor site morbidity compared to the ms-2-TRAM-flap. The study also showed that good preoperative muscle function might increase the probability of surgeons performing a DIEP-flap reconstruction. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Sun, Ruimei; Ding, Yu; Sun, Chuanzheng; Li, Xiaojiang; Wang, Jinde; Li, Lei; Yang, Jie; Ren, Yanxin; Zhong, Zhaoming
2016-04-01
To determine the importance of adequate preoperative assessment with color Doppler sonography to assist in the successful transfer of lateral upper arm flaps by studying the lateral upper arm flap with color Doppler sonography and analyzing the anatomic features of the radial collateral artery. A clinical case-control study was performed. The radial collateral artery was studied with color Doppler sonography in 15 healthy volunteers. The origins, courses, variations, and locations of the perforators of the radial collateral artery were recorded. The results and data from the color Doppler sonographic investigation were compared with an anatomic study that was performed on 22 adult cadaveric upper limb specimens. The volunteer group (14 of 15 volunteers) and the cadaveric group (19 of 22 upper arm specimens) clearly showed that the branch pattern of the arterial supply was as follows: brachial artery → deep brachial artery → radial collateral artery → posterior radial collateral artery → myocutaneous perforator. Variations in the origin of the radial collateral artery were identified in 1 volunteer bilaterally and in 3 upper arm specimens. The diameters of the artery and vein measured at the distal insertion of the deltoid and the origin of the deep brachial artery were not significantly different between the volunteer and cadaver groups (P > .05). Due to the difference in measuring methods, the length of the vascular pedicles was significantly different between the groups (P < .05). Color Doppler sonography can facilitate the preoperative assessment of the origin, course, variations, and locations of the radial collateral artery and therefore may increase the success rate of lateral upper arm flap transfer. © 2016 by the American Institute of Ultrasound in Medicine.
Visconti, Giuseppe; Tomaselli, Federica; Monda, Anna; Barone-Adesi, Liliana; Salgarello, Marzia
2015-01-01
In deep inferior epigastric artery perforator (DIEP) flap breast reconstruction, abdominal donor-site cosmetic and sensibility outcomes and the closure technique have drawn little attention in the literature, with many surgeons still following the principles of standard abdominoplasty. In this article, the authors report their experience with the cannula-assisted, limited undermining, and progressive high-tension suture ("CALP") technique of DIEP donor-site closure compared with standard abdominoplasty. Between December of 2008 and January of 2013, 137 consecutive women underwent DIEP flap breast reconstruction. Of these, 82 patients (between December of 2008 and November of 2011) underwent DIEP flap donor-site closure by means of standard abdominoplasty (control group) and 55 patients (from December of 2011 to January of 2013) by means of cannula-assisted, limited undermining, and progressive high-tension suture (study group). The abdominal drainage daily output, donor-site complications, abdominal skin sensitivity at 1-year follow-up, cosmetic outcomes, and patient satisfaction were recorded and analyzed statistically. Daily drainage output was significantly lower in the study group. Donor-site complications were significantly higher in the control group (37.8 percent versus 9 percent). Seroma and wound healing problems were experienced in the control group. Abdominal skin sensibility was better preserved in the study group. Overall, abdominal wall aesthetic outcomes were similar in both groups, except for scar quality (better in the study group). According to the authors' experience, cannula-assisted, limited undermining, and progressive high-tension suture should be always preferred to standard abdominoplasty for DIEP donor-site closure to reduce the complication rate to improve abdominal skin sensitivity and scar quality. Therapeutic, II.
Free-flap harvesting from paralytic limbs of poliomyelitis patients--a safe and feasible option.
Chan, R C L; Liu, H L; Chan, Y W
2012-06-01
Many patients who had childhood poliomyelitis are still suffering from the late sequalae of the condition. Free-flap harvesting from the paralytic limbs from these patients is a logical approach for functional preservation. However, concerns have been raised regarding its safety due to its hypoplastic vascular system and potential donor site healing problems. A 53-year-old man with known childhood poliomyelitis presented with left facial sarcoma. After wide excision, the defect was reconstructed with a dual-island fasciocutaneous-free anterolateral thigh flap harvested from his paralytic limb. The pedicle and perforators were found to be no different from those in normal limbs. His recovery was smooth without complications. On the basis of our experience and current evidence in the literature, we believe that free-flap harvesting from the paralytic lower limb in poliomyelitis patients is a safe option that incurs no additional risk and allows maximal function preservation. Copyright © 2011. Published by Elsevier Ltd.
Kaartinen, Ilkka S; Vuento, Maarit H; Hyöty, Marja K; Kallio, Jukka; Kuokkanen, Hannu O
2015-01-01
Total pelvic exenteration (TPE) is a rare operation in which the pelvic contents are removed entirely. Several options for pelvic floor and vaginal reconstruction have been described including transverse rectus abdominis musculocutaneous (TRAM) or deep inferior epigastric perforator (DIEP) flaps. The transverse musculocutaneous gracilis (TMG) flap has been introduced for breast reconstruction as a free flap. We adopted the pedicled TMG flap for reconstructions after TPE. To the best of our knowledge, this is the first report of this method in the literature. Between November 2011 and February 2014, 12 patients underwent TPE and reconstruction with unilateral (six patients) or bilateral (six patients) pedicled TMG flaps. Five patients underwent vaginal reconstruction with bilateral TMG flaps. We describe the operative procedure and the outcome of the operation in these patients. The total mean operative times for TPE with or without vaginal reconstruction were 467 ± 12 and 386 ± 59 min, respectively. The TMG flaps had enough vascular tissue and mobility for reconstructing the TPE defects. There was distal edge necrosis in one out of 18 flaps, while the rest survived completely. During the follow-up, complete wound healing with no signs of weakening of the pelvic floor was observed in all cases. Soft-tissue reconstructions are needed to reduce complications associated with TPE, to secure the pelvic floor and to reconstruct the vagina in select patients. The TMG flap is a logical flap choice that does not lead to functional deficits, complicate the abdominal ostomies or weaken the abdominal wall. It reduces the length of operation compared to that of abdominal flaps. IV, therapeutic. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Technique and outcomes of laparoscopic bulge repair after abdominal free flap reconstruction.
Lee, Johnson C; Whipple, Lauren A; Binetti, Brian; Singh, T Paul; Agag, Richard
2016-01-21
Bulges and hernias after abdominal free flap surgery are uncommon with rates ranging from as low as 0-36%. In the free flap breast reconstruction population, there are no clear guidelines or optimal strategies to treating postoperative bulges. We describe our minimally invasive technique and outcomes in managing bulge complications in abdominal free flap breast reconstruction patients. A retrospective review was performed on all abdominal free flap breast reconstruction patients at Albany Medical Center from 2011 to 2014. All patients with bulges on clinical exam underwent abdominal CT imaging prior to consultation with a minimally invasive surgeon. Confirmed symptomatic bulges were repaired laparoscopically and patients were monitored regularly in the outpatient setting. Sixty-two patients received a total of 80 abdominal free flap breast reconstructions. Flap types included 41 deep inferior epigastric perforator (DIEP), 36 muscle-sparing transverse rectus abdominus myocutaneous (msTRAM), 2 superficial inferior epigastric artery, and 1 transverse rectus abdominus myocutaneous flap. There were a total of 9 (14.5%) bulge complications, with the majority of patients having undergone msTRAM or DIEP reconstruction. There were no complications, revisions, or recurrences from laparoscopic bulge repair after an average follow-up of 181 days. Although uncommon, bulge formation after abdominal free flap reconstruction can create significant morbidity to patients. Laproscopic hernia repair using composite mesh underlay offers an alternative to traditional open hernia repair and can be successfully used to minimize scarring, infection, and pain to free flap patients who have already undergone significant reconstructive procedures. © 2016 Wiley Periodicals, Inc. Microsurgery, 2016. © 2016 Wiley Periodicals, Inc.
Hultman, Charles Scott; Kim, Sendia; Lee, Clara N; Wu, Cindy; Dodge, Becky; Hultman, Chloe Elizabeth; Roach, S Tanner; Halvorson, Eric G
2016-06-01
Perforator flaps have become a preferred method of breast reconstruction but can consume considerable resources. We examined the impact of a Six Sigma program on microsurgical breast reconstruction at an academic medical center. Using methods developed by Motorola and General Electric, we applied critical pathway planning, workflow analysis, lean manufacturing, continuous quality improvement, and defect reduction to microsurgical breast reconstruction. Primary goals were to decrease preoperative-to-cut time and total operative time, through reduced variability and improved efficiency. Secondary goals were to reduce length of stay, complications, and reoperation. The project was divided into 3 phases: (1) Pre-Six Sigma (24 months), (2) Six Sigma (10 months), (3) and Post-Six Sigma (24 months). These periods (baseline, intervention, control) were compared by Student t test and χ analysis. Over a 5-year period, 112 patients underwent 168 perforator flaps for breast reconstructions, by experienced microsurgeons. Total operative time decreased from 714 to 607 minutes (P < 0.01), across the study period, with the greatest drop occurring in unilateral cases, from 672 to 498 minutes (P < 0.01). Length of stay decreased from 6.3 to 5.2 days (P = 0.01). Overall complication rates (35.9% vs 30%, not significant) and take-back rates (20.5% vs 23.9%, not significant) remained similar over the 5-year period. Physician revenue/minute increased from US $6.28 to US $7.59, whereas hospital revenue/minute increased from US $21.84 to US $25.11. A Six Sigma program in microsurgical breast reconstruction was associated with better operational and financial outcomes. These incremental gains were maintained over the course of the study, suggesting that these benefits were due, in part, to process improvements. However, continued reductions in total operative time and length of stay, well after the intervention period, support the possibility that "learning curve" phenomenon may have contributed to the improvement in these outcomes.
Brongo, Sergio; Campitiello, Nicola; Rubino, Corrado
2014-01-01
The reconstruction of lower third of the leg is one of the most challenging problems for plastic and reconstructive surgeons and current approaches are still disappointing. We show an easy option to obtain a coverage of traumatic pretibial defects with good aesthetic and functional results: the association of negative pressure wound therapy, acellular dermal matrix, and skin graft. The choice of this combined therapy avoids other surgical procedures such as local perforator flaps and free flaps that require more operating time, special equipment, and adequate training. PMID:25177509
Bone recycling in nasal septal reconstruction.
Apaydin, Fazil
2013-12-01
Septal reconstruction alone or together with rhinoplasty can be a very challenging operation. In situations where septal cartilage is used for grafting or is not enough, bony implants taken from the perpendicular plate of the ethmoid and vomer can be used as a filler material between the mucoperichondrial flaps to avoid from unwanted mucosal atrophy, flapping, and septal perforation. These bony implants can also be used for splinting the dorsal and/or caudal segment of the septal cartilage after reshaping by rongeurs. On rare occasions, they can even be used for subtotal reconstruction of the septum. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Breast-volume displacement using an extended glandular flap for small dense breasts.
Ogawa, Tomoko; Hanamura, Noriko; Yamashita, Masako; Kimura, Hiroko; Kashikura, Yumi
2011-01-01
We defined the glandular flap including fat in the subclavicular area as an extended glandular flap, which has been used for breast-conserving reconstruction in the upper portion of the breast. Indication. The excision volume was 20% to 40% of the breast volume, and the breast density was dense. Surgical Technique. The upper edge of the breast at the subclavicular area was drawn in the standing position before surgery. After partial mastectomy, an extended glandular flap was made by freeing the breast from both the skin and the pectoralis fascia up to the preoperative marking in the subclavicular area. It is important to keep the perforators of the internal mammary artery and/or the branches of the lateral thoracic artery intact while making the flap. Results. Seventeen patients underwent remodeling using an extended glandular flap. The cosmetic results at 1 year after the operation: excellent in 11, good in 1, fair in 3, and poor in 2. All cases of unacceptable outcome except one were cases with complications, and more than 30% resection of moderate or large size breasts did not obtain an excellent result for long-term followup. Conclusion. This technique is useful for performing the breast-conserving reconstruction of small dense breasts.
Laser-grid trabeculectomy in rabbits: an experimental in-vivo study.
Dietlein, Thomas S; Jacobi, Philipp C; Krieglstein, Günter K
2002-02-01
Laser-grid trabeculectomy (TE) is a modification of micro-TE designed to enhance the intra- and postoperative safety of filtering surgery by creating several small oval fistulas (max. diameter <200 microm) beneath a scleral flap without peripheral iridectomy. After dissecting the conjunctiva and a conventional scleral flap, 10 small perforating fistulas were created in five pigmented rabbits in the region of the gray-white border using an erbium:YAG laser with a beveled side-firing 200 microm endoprobe; conventional TE with iridectomy was performed in another five animals. Anterior chamber inspection and IOP measurements of both eyes were conducted on days 1, 4, and 14 after operation. After the last inspection eyes were saved for morphological analysis. Both procedures (laser-grid and conventional TE) led to a reduction of intraocular pressure in the treated eye compared to the control eye. Differences between the outcomes for the two procedures were not statistically significant. Morphology of the eyes treated by laser-grid TE revealed dense scarring of perforations around the center of the ligamenta pectinata and loose tissue refilling of the more peripheral openings. The functional outcome of laser-grid TE in rabbits was similar to that of conventional TE in the short term. Histological examination of microperforations in the area of the trabecular meshwork after 2 weeks indicated that tissue repair was less pronounced than in the more anterior perforations. This morphologic finding may be of importance for non-penetrating glaucoma surgery.
Chi, Zhenglin; Lin, Damu; Chen, Yiheng; Xue, Jixin; Li, Shi; Chu, Tinggang; Li, Zhijie
2018-06-01
Closure of the donor site on the index finger after raising a first dorsal metacarpal artery (DMA) flap harvest is challenging. The conventional choice is to use a full-thickness skin graft. However, this procedure is associated with several complications and a second donor site to harvest the skin graft is inevitable. The aim of this study was to design a modified incision to allow harvest of a first DMA flap without skin graft. From 2015 to 2016, 18 patients with a soft tissue defect of the thumb had reconstruction of the defect using a first DMA flap. A modified incision was used and a relaying perforator flap pedicled on the second DMA was raised through the same incision to cover the donor site. Patient satisfaction, appearance of the injured hand, and the active range of motion (ROM) were assessed. The sensitivity was evaluated by the 2-point discrimination (2-PD) test. All flaps survived completely without complications. Good coverage was obtained with only one linear scar in the dorsum of the hand and no skin grafts. All patients recovered full range of movement in their fingers and regained sensitivity of the flaps. All patients were satisfied with their hand function according to the Michigan Hand Outcomes Questionnaire (MHQ). The mean cosmetic score for the appearance of the injured hand was 8.2 out of 10. Using our modified incision, it was possible to harvest a second DMA flap at the same time as a first DMA flap allowing simultaneous coverage of the donor defect on the index finger. This prevented the need for a skin graft with all of the associated disadvantages. Copyright © 2018. Published by Elsevier Ltd.
The midabdominal TRAM flap for breast reconstruction in morbidly obese patients.
Gabbay, Joubin S; Eby, Joseph B; Kulber, David A
2005-03-01
The transverse rectus abdominis myocutaneous (TRAM) flap is ideal for postmastectomy reconstruction but is tenuous in morbidly obese patients. Because of their relatively high incidence of postoperative complications, morbidly obese patients are often not considered candidates for autogenous reconstruction. The midabdominal TRAM flap has a more favorable anatomy and may represent an alternative technique in this patient population. The records of 18 morbidly obese patients who underwent postmastectomy reconstruction using a mid-abdominal TRAM flap from 1998 through 2002 were retrospectively reviewed. The mid-abdominal TRAM flap territory includes more of the supraumbilical region than the traditional TRAM flap, corresponding to an area with more abundant musculocutaneous perforators and greater dependence on the superior epigastric vascular system. All patients underwent unipedicled mid-abdominal TRAM flap surgery. Four patients with previous subumbilical midline incisions had a delay procedure with ligation of the inferior epigastric vessels. Complications investigated were flap necrosis greater than 10 percent or sufficient to require surgical revision, abdominal donor-site breakdown, seroma formation, umbilical necrosis, abdominal wall bulging or hernia, deep vein thrombosis, infected mesh, surgical revisions, fat necrosis, and extended hospital stay. At a mean follow-up time of 15.6 months (range, 12 to 24 months), three patients had postoperative complications requiring surgical revision. Two of these patients had previous midline abdominal incisions. One patient had both partial flap necrosis and a donor-site complication. The second patient had partial flap necrosis, and the third had an abdominal donor-site complication. No occurrences of abdominal wall hernia, total flap loss, deep vein thrombosis, infected mesh, extensive surgical revision, or extended hospitalization were noted in this series. The mid-abdominal TRAM flap represents an alternative method for postmastectomy breast reconstruction in morbidly obese patients. Autologous reconstruction using a midabdominal TRAM flap may be considered in this patient population; however, additional research is required to conclusively demonstrate an improved outcome when compared with traditional reconstructive methods.
[Use of indocyanine green angiography in reconstructive surgery: Brief review].
Echalier, C; Pluvy, I; Pauchot, J
2016-12-01
The success of flap surgery is highly dependant of vascularisation, according to the principle of dermal and subdermal perfusion. This principle requires compatible dimensions for the survival of the flap. Indocyanine green angiography (ICG), a technique enabling an assessment of vascularization by fluorescence, has received a considerable impetus during the last two decades. The purpose of this article was to conduct a review on this technique and to evaluate its relevance in flap surgery. We reviewed all articles referenced on PubMed from 1995 till 2015 using a search combining the terms 'indocyanine green', 'flap', 'near-infrared', 'fluorescence', 'imaging' OR 'angiography'. One hundred fifty five articles were found and among those thirty-four were selected. ICG is a reliable technique to locate perforants vessels, to determine the outlines of the flat and evaluate its per- and postoperative viability and to appraise anastomoses. This technique allows a reliable and real-time assessment of potential necrotic areas and an improvement in the detection of complications compared to conventional techniques. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Use of various free flaps in progressive hemifacial atrophy.
Baek, Rongmin; Heo, Chanyeong; Kim, Baek-kyu
2011-11-01
Romberg disease is an uncommon condition manifested by progressive hemifacial atrophy of the skin, soft tissue, and bone. Facial asymmetry with soft tissue deficiency in Romberg disease causes a significant disability affecting the social life and can bring about many psychological problems. The aim of surgical treatment is cosmetic amelioration of the defect. Several conventional reconstructive procedures have been used for correcting facial asymmetry. They include fat injections, dermal fat grafts, filler injections, cartilage and bone grafts, and pedicled and free flaps. We report our experiences with 11 patients involving 11 free flaps with a minimum 1-year follow-up. All patients were classified as having moderate to severe atrophy. The average age at disease onset was 4.5 years; the average duration of atrophy was 5.2 years. No patients were operated on with a quiescent interval of less than 1 year. The average age at operation was 20.1 years, ranging from 10 to 55 years. Reconstruction was performed using 4 groin dermofat free flaps, 4 latissimus dorsi muscle free flaps, and 3 other perforator flaps. To achieve the finest symmetrical and aesthetic results, several ancillary procedures were performed in 4 patients. These procedures included Le Fort I leveling osteotomy, sagittal split ramus osteotomy, reduction malarplasty and angle plasty, rib and calvarial bone graft, correction of alopecia, and additional fat graft. All patients were satisfied with the results. We believe that a free flap transfer is the requisite treatment modality for severe degree of facial asymmetry in Romberg disease.
Near-infrared imaging of face transplants: are both pedicles necessary?
Nguyen, John T; Ashitate, Yoshitomo; Venugopal, Vivek; Neacsu, Florin; Kettenring, Frank; Frangioni, John V; Gioux, Sylvain; Lee, Bernard T
2013-09-01
Facial transplantation is a complex procedure that corrects severe facial defects due to traumas, burns, and congenital disorders. Although face transplantation has been successfully performed clinically, potential risks include tissue ischemia and necrosis. The vascular supply is typically based on the bilateral neck vessels. As it remains unclear whether perfusion can be based off a single pedicle, this study was designed to assess perfusion patterns of facial transplant allografts using near-infrared (NIR) fluorescence imaging. Upper facial composite tissue allotransplants were created using both carotid artery and external jugular vein pedicles in Yorkshire pigs. A flap validation model was created in n = 2 pigs and a clamp occlusion model was performed in n = 3 pigs. In the clamp occlusion models, sequential clamping of the vessels was performed to assess perfusion. Animals were injected with indocyanine green and imaged with NIR fluorescence. Quantitative metrics were assessed based on fluorescence intensity. With NIR imaging, arterial perforators emitted fluorescence indicating perfusion along the surface of the skin. Isolated clamping of one vascular pedicle showed successful perfusion across the midline based on NIR fluorescence imaging. This perfusion extended into the facial allograft within 60 s and perfused the entire contralateral side within 5 min. Determination of vascular perfusion is important in microsurgical constructs as complications can lead to flap loss. It is still unclear if facial transplants require both pedicles. This initial pilot study using intraoperative NIR fluorescence imaging suggests that facial flap models can be adequately perfused from a single pedicle. Copyright © 2013 Elsevier Inc. All rights reserved.
Tessone, Ariel; Nava, Maurizio; Blondeel, Phillip; Spano, Andrea
2016-02-01
Ever since its introduction, the transverse rectus abdominis myocutaneous flap has become the mainstay of autologous breast reconstruction. However, concerns regarding donor site morbidity due to the breach of abdominal wall musculature integrity soon followed. Muscle-sparing techniques, eventually eliminating the muscle from the flap all-together with the deep inferior epigastric artery perforator flap, did not eliminate the problem of abdominal wall weakness. This led to the conclusion that motor innervation might be at fault. Studies have shown that even in the presence of an intact rectus abdominis muscle, and an intact anterior rectus sheath, denervation of the rectus abdominis muscle results in significant abdominal wall weakness leading to superior and inferior abdominal bulges, and abdominal herniation. Our aim was to establish a mathematical model to predict the location of the motor innervation to the rectus abdominis muscle, and thus provide surgeons with a tool that will allow them to reduce abdominal morbidity during deep inferior epigastric artery perforator and free muscle-sparing transverse rectus abdominis myocutaneous surgery. We dissected 42 cadaveric hemiabdomens and mapped the course of the thoracolumbar nerves. We then standardized and analyzed our findings and presented them as a relative map which can be adjusted to body type and dimensions. Our dissections show that the motor innervation is closely related to the lateral vascular supply. Thus, when possible, we support the preferred utilization of the medial vascular supply, and the preservation of the lateral supply and motor innervation.
Retroauricular skin: a flaps bank for ear reconstruction.
Cordova, A; D'Arpa, S; Pirrello, R; Giambona, C; Moschella, F
2008-01-01
The retroauricular skin has always been given much attention by the reconstructive surgeon for ear and face reconstruction because it is richly vascularised, as many anatomical investigations show, it is hidden behind the ear, its skin is very similar to that of ear and face. All these reasons make it an ideal donor site for ear reconstruction. The authors propose their own algorithm for reconstruction of every kind of anterior defects of the auricle with different Retroauricular Island Flaps (RIFs) based on the location and size of the defect developed over a 16 years single institution's experience with a series of 216 consecutive cases. 216 patients have undergone ear reconstruction with RIFs from 1999 to 2006. In 52 a Superior Pedicle RIF (SP-RIF) was used for defects of the upper half of the auricle. In 68 cases a Perforator RIF (P-RIF) was used for conchal reconstruction. In 96 cases an Inferior Pedicle RIF (IP-RIF) was used for reconstruction of nonmarginal and superficial marginal defects of the auricle. No flap failure was recorded. Excellent morphological reconstruction was obtained with these flaps with no sequealae at the donor site in terms of form and function. Only in the case of P-RIFs the sulcus becomes flat in its central part, but this has never affected the possibility of wearing spectacles. The SP-RIFs may sometimes show some signs of venous stasis that invariably resolve in the first two postoperative days. The retroauricular skin may be considered a flaps bank for ear reconstruction. It offers in fact a great variety of island flaps that are suitable for every kind of loss of substance of the ear, have a safe vascularisation, skin of similar colour and texture, are easy to harvest under local anaesthesia on an outpatient basis and cause no relevant morbidity at the donor site. Location and size of the defects lead the choice between the different types of RIFs.
TDAP: Island versus propeller.
Angrigiani, Claudio; Rancati, Alberto; Artero, Guillermo; Escudero, Ezequiel; Khouri, Roger K
2016-04-01
Thoracodorsal artery perforator (TDAP) island flap is a safe and reliable method for breast reconstruction. TDAP propeller flap has been described as a modification of the conventional island technique that saves time and does not require microsurgical skills. However, a substantial portion of the propeller flap remains under the axilla and is not used for breast augmentation. The aim of this study is to identify the differences in the reaching distances between the propeller and island TDAP flaps. In five cadaveric specimens and 10 breast reconstruction patients, an initial propeller flap was harvested and rotated to the anterior thorax; the distance from the tip of the flap to the anterior midline was recorded as the "midline-reaching deficit;" the flap was then converted into a conventional island flap, and the new midline-reaching deficit was recorded. Differences between groups were compared with paired two-tailed t-tests (α = 0.05). In the cadaveric specimens, the mean midline-reaching deficit was 4.8 ± 2.4 cm with the propeller TDAP and -0.6 ± 2.0 cm with the conventional island TDAP (P < 0.001). In the clinical cases, the mean midline-reaching deficit was 8.1 ± 1.0 cm with the propeller TDAP and -0.3 ± 1.1 cm with the island TDAP (P < 0.000000001). We observed that the midline-reaching deficit could be reduced by 7-9 cm with the conventional island TDAP in comparison to the propeller TDAP. This should be considered when reconstructing the medial inner part of the breast. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Long-Term Follow-Up of Quality of Life following DIEP Flap Breast Reconstruction.
Hunsinger, Vincent; Hivelin, Mikael; Derder, Mohamed; Klein, Delphine; Velten, Michel; Lantieri, Laurent
2016-05-01
Sequelae resulting from breast cancer negatively impact patients' quality of life. Although the deep inferior epigastric perforator (DIEP) flap has become a standard for autologous breast reconstruction, there are limited data regarding long-term quality of life. The authors studied patients' quality of life more than 5 years after DIEP flap breast reconstruction and compare it with two French reference samples. A cross-sectional study of quality of life was performed in women who underwent DIEP flap breast reconstruction between 1995 and 2007 using the Medical Outcomes Study 36-Item Health Survey (Short Form-36). The first reference sample included subjects from the French general population (n = 3308), and the second included cancer survivors who underwent mastectomy with (n = 70) or without (n = 135) breast reconstruction. One hundred eleven respondents were analyzed among 186 eligible women. The mean follow-up period after reconstruction was 8.6 years (range, 5 to 15 years). There were no statistically significant differences in the quality of life between women from 45 to 64 years old who underwent DIEP flap breast reconstruction and from the French general population. Five of the eight Short Form-36 dimensions were significantly better in the DIEP flap breast reconstruction group in the 65- to 74-year-old cohort. In addition, quality of life of our study population was significantly higher than that of women who underwent mastectomy with or without any type of breast reconstruction. These results indicate that DIEP flap breast reconstruction allows patients with breast cancer to maintain a good postoperative quality of life comparable to that of the general population. Therapeutic, III.
Pratt, Philip; Ives, Matthew; Lawton, Graham; Simmons, Jonathan; Radev, Nasko; Spyropoulou, Liana; Amiras, Dimitri
2018-01-01
Precision and planning are key to reconstructive surgery. Augmented reality (AR) can bring the information within preoperative computed tomography angiography (CTA) imaging to life, allowing the surgeon to 'see through' the patient's skin and appreciate the underlying anatomy without making a single incision. This work has demonstrated that AR can assist the accurate identification, dissection and execution of vascular pedunculated flaps during reconstructive surgery. Separate volumes of osseous, vascular, skin, soft tissue structures and relevant vascular perforators were delineated from preoperative CTA scans to generate three-dimensional images using two complementary segmentation software packages. These were converted to polygonal models and rendered by means of a custom application within the HoloLens™ stereo head-mounted display. Intraoperatively, the models were registered manually to their respective subjects by the operating surgeon using a combination of tracked hand gestures and voice commands; AR was used to aid navigation and accurate dissection. Identification of the subsurface location of vascular perforators through AR overlay was compared to the positions obtained by audible Doppler ultrasound. Through a preliminary HoloLens-assisted case series, the operating surgeon was able to demonstrate precise and efficient localisation of perforating vessels.
[Breast reconstruction: autologous tissue versus implant].
Plogmeier, K; Handstein, S; Schneider, W
1998-01-01
Modified radical mastectomy remains the standard for treatment of breast cancer. Women faced with the diagnosis of breast cancer often find it difficult to cope with the arousing emotions. Fear of death or cancer recurrence and a perceived loss of femininity often coexists with the desire for a return to normality and wholeness. For women seeking breast reconstruction various techniques have been developed. Two different ways for breast reconstruction have become a standard. One way is the reconstruction by tissue expansion or transposing locally available tissue with the use of implants. The other way is the reconstruction of the breast without using any implants with the Latissimus dorsi flap or the TRAM flap. We performed 291 breast reconstructions. In 125 women available tissue and an implant was used. The Latissimus dorsi flap was used in 57 cases and 109 TRAM flaps either pedicled or as a microvascular flap were performed. Using expanders we found a perforation of the device in 2 cases. After using implants there were capsular contracture in 2 cases and in 1 case we had an infection. Using autologous tissue we had 2 partial flap necrosis, 4 hematomas, and 4 prolonged healings. There was no complete flap necrosis. Breast reconstruction using autologous tissue i.e. the TRAM flap is supposed to be a standard technique. Microsurgical transplantation of the TRAM flap shows almost no morbidity of the donor site area. Autologous tissue follows the changes of the body like weight gain or reduction to a certain extend and shows neither capsular contracture nor other implant associated side effects. Women get the impression that the TRAM flap is like soft tissue to the touch and not like a foreign body. The aesthetic results were in all cases superior sometimes needing minor secondary correction and mostly shaping of the nippel-areola complex. All patients were pleased with the result.
Causes, treatment and prevention of esophageal fistulas in anterior cervical spine surgery.
Sun, Lin; Song, Yue-ming; Liu, Li-min; Gong, Quan; Liu, Hao; Li, Tao; Kong, Qing-quan; Zeng, Jian-cheng
2012-11-01
To evaluate the causes, treatment and prevention of esophageal fistulas after anterior cervical spine surgery. Between January 2004 and December 2011, 5 of 2348 patients who underwent anterior cervical surgery in our hospital developed esophageal fistulas (three male and two female patients, average age 34 years). Their diagnoses were cervical injuries (three), cervical spondylosis (one) and cervical tuberculosis (one). Their esophageal fistulas were treated by debridement and exploratory surgery, primary suturing of the perforation and/or sternocleidomastoid myoplasty. If conservative treatment failed or esophageal fistula recurred, plate removal was offered. Postoperative treatment included esophageal rest, enteral nutrition, wound drainage, and antibiotics. Methylene blue was used to evaluate results. An esophageal fistula was discovered during anterior cervical surgery in one patient and primary suturing performed. In four patients, fistulas were diagnosed after anterior cervical decompression and fusion. In one of these, only debridement and exploratory surgery were required. In another, a perforation was sutured during debridement and exploratory surgery. In the third, internal fixation was removed because of failure of prolonged conservative treatment. In the fourth, the esophageal fistula recurred repeatedly; he required removal of the hardware and reinforcement with a sternocleidomastoid muscle flap. At 6-48 months follow-up, all patients were in good condition, symptom free, and without cervical instability or infectious spondylitis. Successful management of esophageal fistula after anterior cervical spinal surgery depends on primary closure of the perforation with or without muscle flaps, surgical drainage, esophageal rest and nutritional support, and removal of hardware if necessary. Prevention consists of careful surgery and gentle tissue handling. © 2012 Tianjin Hospital and Wiley Publishing Asia Pty Ltd.
Na, Deng; Wei, He; Rui, Li; Wenlu, Li; Ning, Gao; Wen, Zhang
2015-04-01
This study aims to evaluate the quality of life (QOL) of patients who underwent resection of oral cancer and reconstruction by free anierolateral thigh perforator flaps (ALTF). A total of 32 patients with oral and maxillofacial malignancies who had undergone the resection of oral cancer and reconstruction by ALTF were retrospectively analyzed. At 12 months postoperatively, the QOL of these patients was assessed by using the 14-item oral health impact profile (OHIP-14) and the medical outcome study short form-36 (SF-36) questionnaires. A total of 32 questionnaires were collected. In SF-36, the highest scoring domains were bodily pain (78.58 ± 14.82), physical functioning (72.08 ± 27.86), and the role of physical (60.00 ± 42.63), whereas the lowest scoring domains were role-emotional (41.67 ± 39.62), followed by mental health (50.75 ± 13.07) and health transition (54.17 ± 21.75). In OHIP-14, the lowest scoring domains were social disability (34.50 ± 11.32) and handicap (36.04 ± 12.05), indicating the functional recovery was better; and the highest scoring domains were physical pain (73.50 ± 18.96) and psychological discomfort (60.17 ± 20.66), indicating the functional recovery was worse. The ALTF is an ideal selection for the reconstruction of oral defects after cancer resection. In using this flap, the basic social need of patients after surgery can be satisfied. Moreover, the appearance and the functions of chewing, deglutition, and speech can be restored in varying degrees. Thus, ALTF can improve the patients' QOL.
Kim, So Young; Lee, Kyeong-Tae; Mun, Goo-Hyun
2017-03-01
A Pfannenstiel incision involves the obstruction of superficial venous pathways and functional diversion of flow through alternative pathways and adjacent vessels. This study investigated the effect of a prior Pfannenstiel incision on venous anatomy of the lower abdominal wall; specifically, the superficial inferior epigastric vein (SIEV), using computed tomographic angiography. A case-control study was performed of 50 patients with Pfannenstiel scars and 50 age-matched, body mass index-matched control patients without Pfannenstiel scars. The authors compared the number of direct/indirect and total communications between the SIEV and deep inferior epigastric artery perforator (DIEP) venae comitantes, midline crossover, and other SIEV-related anatomical changes by using computed tomographic angiography. Flap-related clinical outcomes and donor-site-related complications were also assessed. The median number of direct and total communications between the SIEV and DIEP venae comitantes in the study group was greater than in the control group. The percentage of SIEVs having more than two branching patterns per hemiabdomen was significantly higher in the study group than in the control group. The study group also showed a significantly lower rate of fat necrosis compared with the control group (p = 0.03). The rate of donor-site seroma was significantly higher in the study group. This study suggests that the presence of a Pfannenstiel scar may promote the development of direct and total communications between the SIEV and DIEP venae comitantes and branching within the SIEV in the lower abdominal wall, which may facilitate venous drainage of adipose tissue in DIEP flap breast reconstruction. Risk, II.
Chae, Michael P.; Hunter-Smith, David J.
2015-01-01
Background The high incidence of breast cancer and growing number of breast cancer patients undergoing mastectomy has led to breast reconstruction becoming an important part of holistic treatment for these patients. In planning autologous reconstructions, preoperative assessment of donor site microvascular anatomy with advanced imaging modalities has assisted in the appropriate selection of flap donor site, individual perforators, and lead to an overall improvement in flap outcomes. In this review, we compare the accuracy of fluorescent angiography, computed tomographic angiography (CTA), and magnetic resonance angiography (MRA) and their impact on clinical outcomes. Methods A review of the published English literature dating from 1950 to 2015 using databases, such as PubMed, Medline, Web of Science, and EMBASE was undertaken. Results Fluorescent angiography is technically limited by its inability to evaluate deep-lying perforators and hence, it has a minimal role in the preoperative setting. However, it may be useful intraoperatively in evaluating microvascular anastomotic patency and the mastectomy skin perfusion. CTA is currently widely considered the standard, due to its high accuracy and reliability. Multiple studies have demonstrated its ability to improve clinical outcomes, such as operative length and flap complications. However, concerns surrounding exposure to radiation and nephrotoxic contrast agents exist. MRA has been explored, however despite recent advances, the image quality of MRA is considered inferior to CTA. Conclusions Preoperative imaging is an essential component in planning autologous breast reconstruction. Fluorescent angiography presents minimal role as a preoperative imaging modality, but may be a useful intraoperative adjunct to assess the anastomosis and the mastectomy skin perfusion. Currently, CTA is the gold standard preoperatively. MRA has a role, particularly for women of younger age, iodine allergy, and renal impairment. PMID:26005648
Current trends in breast reconstruction: survey of American Society of Plastic Surgeons 2010.
Gurunluoglu, Raffi; Gurunluoglu, Aslin; Williams, Susan A; Tebockhorst, Seth
2013-01-01
We conducted a retrospective survey of American Society of Plastic Surgeons to ascertain the current trends in breast reconstruction (BR). Surveys were sent to 2250 active American Society of Plastic Surgeons members by e-mail with a cover letter including the link using Survey Monkey for the year 2010. In all, 489 surveys (a response rate of 21.7%) were returned. Three hundred fifty-eight surveys from respondents performing BR in their practices were included in the study. The survey included questions on surgeon demographics, practice characteristics, BR after mastectomy, number of BR per year, type and timing of BR, use of acellular dermal matrix, reconstructive choices in the setting of previous irradiation and in patients requiring postmastectomy radiation therapy, timing of contralateral breast surgery, fat grafting, techniques used for nipple-areola reconstruction, the complications, and physician satisfaction and physician reported patient satisfaction. Returned responses were tabulated and assessed. After prophylactic mastectomy, 16% of BRs were performed. In all, 81.2% of plastic surgeons predominantly performed immediate BR. In patients requiring postmastectomy radiation therapy, 81% did not perform immediate BR. Regardless of practice setting and laterality of reconstruction, 82.7% of respondents predominantly performed implant-based BR. Half of the plastic surgeons performing prosthetic BR used acellular dermal matrix. Only 14% of plastic surgeons predominantly performed autologous BR. Surgeons in solo, plastic surgery group practices, and multispecialty group practices preferred implant-based BR for both unilateral and bilateral cases more frequently than those in academic practices (P < 0.05). Overall, plastic surgeons in academic settings preferred autologous BR more frequently than those in other practice locations (P < 0.05). Of total respondents, 64.8% did not perform microsurgical BR at all; 28% reported performing deep inferior epigastric perforator flap BR. Pedicled transverse rectus abdominis myocutaneous flap was the most often used option for unilateral autologous reconstruction, whereas deep inferior epigastric perforator flap was the most commonly used technique for bilateral BR. The overall complication rate reported by respondents was 11%. The survey provides an insight to the current trends in BR practice with respect to surgeon and practice setting characteristics. Although not necessarily the correct best practices, the survey does demonstrate a likely portrayal of what is being practiced in the United States in the area of BR.
Xie, Yun; Zhuang, Yue-Hong; Xue, Lan; Zheng, He-Ping; Lin, Jian-Hua
2015-12-01
Gigantic pressure sores pose a daunting challenge for plastic surgeons. This paper presents a composite gluteofemoral flap for reconstruction of large pressure sores over the sacrococcygeal region. In this anatomical study, 30 embalmed cadaveric lower limbs were used for dissection to observe the musculocutaneous perforators of the inferior gluteal artery and the longitudinal nutritional vascular chain of the posterior femoral cutaneous nerve. In this clinical study, eight patients underwent surgical harvest of the composite gluteofemoral flap for coverage of grade IV sacrococcygeal pressure sores. The size of the pressure sores ranged between 16 × 9 cm and 22 × 10 cm. The inferior gluteal artery was present in 26 cases and absent in four cases. It gave off two to four musculocutaneous branches with a diameter larger than 0.5 mm to the gluteus maximus. A direct cutaneous branch was given off at the inferior margin of the gluteus maximus, serving as a nutritional artery for the posterior femoral cutaneous nerve. The size of the flap harvested ranged between 22 × 9 cm and 32 × 10 cm. Flaps in seven patients survived uneventfully and developed epidermal necrosis at the distal margin in one case. An average 2-year follow-up revealed no recurrence of pressure sores. The composite gluteofemoral flap, being robust in blood supply, simple in surgical procedure, and large in donor territory, is an important addition to the armamentarium. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Tu, Yiji; Chen, Zenggan; Lineaweaver, William Charles; Zhang, Feng
2017-12-01
Several recipient vessels can be used in free microsurgical fibula flaps (MFFs) for the treatment of avascular necrosis of the femoral head (ANFH). Few articles investigate the influence of different recipient vessels on outcomes of MFF for ANFH. A comprehensive literature search of databases including PubMed-Medline, Ovid-Embase, and Cochrane Library was performed to collect the related studies. The Medical Subject Headings used were "femur head necrosis" and "bone transplantation." The relevant words in title or abstract included but not limited to "fibula flap," "fibular flap," "vascularized fibula," "vascularized fibular," "free fibula," "free fibular," "femoral head necrosis," "avascular necrosis of femoral head," and "ischemic necrosis of femoral head." The methodological index for nonrandomized studies was adopted for assessing the studies included in this review. Finally, 15 studies encompassing a total of 1267 patients (1603 hips) with ANFH were pooled in the overall analysis. Recipient vessels for MFF included the ascending branch of the lateral circumflex femoral artery and vein in 8 studies, descending branch of the lateral circumflex femoral artery and vein in 2 studies, second perforating branch of the deep femoral artery and vein in 4 studies, and inferior gluteal artery and vein in 1 study. Preoperative and postoperative average Harris hip score and pooled analyses of the rate of conversion, radiographic progression, and hip surgery-related complications showed no significant difference on the outcomes of MFF on ANFH between using different recipient vessels. Different recipient vessels did not affect outcomes in MFF procedures for ANFH. High-quality randomized controlled trials and prospective studies would be necessary to clarify reliable advantages and disadvantages between different recipient vessels. Until then, surgeons are justified in using ascending branch of the lateral circumflex femoral artery and vein, descending branch of the lateral circumflex femoral artery and vein, second perforating branch of the deep femoral artery and vein, and inferior gluteal artery and vein vessels according to care circumstances and customary practice.
Pluvy, I; Bellidenty, L; Ferry, N; Benassarou, M; Tropet, Y; Pauchot, J
2014-04-01
Autologous techniques for breast reconstruction get the best cosmetic results. Aesthetic satisfaction with breast reconstruction is an important evaluation criterion. The indication is based on technical criteria (morphological, medical history) and the wishes of the patient. A rigorous evaluation of the results is necessary to assist the patients in their choice of reconstruction. Thirty-three DIEP and 27 latissimus dorsi were involved. A satisfaction questionnaire was sent to patients to collect the aesthetic evaluation of their reconstructed breast, sequelae at the donor site of the flap as well as their overall satisfaction. Post-operative photographs of the patients were subject to aesthetical evaluation by two groups of observers. Complications were analyzed. The DIEP tends to get higher aesthetic satisfaction regarding the symmetry of the breasts and the volume of the reconstructed breast (P=0.05), and a better overall satisfaction (P=0.02). The uniformity of the colour of the reconstructed breast was considered superior by observers in the latissimus dorsi group (P=0.005). Donor site scar of DIEP was considered more unsightly while the latissimus dorsi was considered more painful (P=0.04) and uncomfortable, with more frequently contour abnormalities (P=0.03). We noted two total flap necrosis and three partial necrosis in the group DIEP, and two partial flap necrosis in the group latissimus dorsi. This study provides evidence that can guide the patient and the surgeon in the complex process of therapeutic decision, without exempting the latter from a careful selection of indications. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Zhang, Xu; Li, Meng-Jie; Fang, Qi-Gen; Sun, Chang-Fu
2014-05-01
Our study investigated the quality of life (QoL) of Chinese patients after immediate reconstruction surgery on individuals with head and neck cancer. In addition, we compared the differences between pectoralis major myocutaneous flap (PMMF) and anterolateral thigh free flap (ALTFF). The University of Washington Quality of Life questionnaire, version 4, was used to assess the QoL. Assessments were performed at least 24 months postoperatively. A total of 110 patients' records were obtained. Among them, 86 patients completed a QoL questionnaire (78.2%). No significant differences could be found in age, primary site, T stage, N stage, and postoperative radiotherapy between PMMF and ALTFF groups. However, there were significant differences between both groups in sex, operation time, and complication. A matched analysis was performed to compare the differences in QoL between patients with head and neck cancers reconstructed with PMMF or ALTFF. Patients reconstructed with ALTFF had better shoulder but worse speech functions. There was a significant effect on the QoL of head and neck cancer patients who had undergone either PMMF or ALTFF reconstruction. The result of this study provide useful information for physicians and patients during their discussion of treatment modalities for head and neck cancers.
Singhal, Dhruv; Smorodinsky, Emmanuil; Guo, Lifei
2011-01-01
Microvascular reconstructive surgery has seen a revival with the introduction of muscle-sparing perforator flaps. Recognition of potential ethnic differences in coagulation profiles would be important to a microvascular surgeon. Based on clinical observations, we hypothesize that Asian patients have a less thrombogenic coagulation profile than Caucasians. An extensive retrospective review was performed. The annual incidence of venous thromboembolism in the United States is generally accepted to range from 70 to 120 events per 100,000 people versus 16 to 17 events per 100,000 persons in Asia. Autopsy analysis of pulmonary embolism incidence was noted to be 15% in North Americans and less than 1% in Asian populations. Thromboelastography analysis of Asian and Caucasian patients undergoing cholecystectomy revealed different hemostatic mechanisms. Comparison of Asians and Caucasians undergoing the Fontan procedure revealed significantly lower postoperative factor levels in Asians than Caucasians. Baseline comparison of factor and serum levels revealed Asians with the least thrombogenic profiles compared with other ethnic groups. Asians and Caucasians demonstrate different baseline rates of deep vein thrombosis and pulmonary embolism, different hemostatic responses to surgery, and different baseline levels of clotting factors. Further study may lead to better pre-, intra-, and postoperative care of the free flap patient based on their ethnic coagulation profile. © Thieme Medical Publishers.
Morrison, Wayne A; Marre, Diego; Grinsell, Damien; Batty, Andrew; Trost, Nicholas; O'Connor, Andrea J
2016-04-01
Tissue engineering is currently exploring new and exciting avenues for the repair of soft tissue and organ defects. Adipose tissue engineering using the tissue engineering chamber (TEC) model has yielded promising results in animals; however, to date, there have been no reports on the use of this device in humans. Five female post mastectomy patients ranging from 35 to 49years old were recruited and a pedicled thoracodorsal artery perforator fat flap ranging from 6 to 50ml was harvested, transposed onto the chest wall and covered by an acrylic perforated dome-shaped chamber ranging from 140 to 350cm(3). Magnetic resonance evaluation was performed at three and six months after chamber implantation. Chambers were removed at six months and samples were obtained for histological analysis. In one patient, newly formed tissue to a volume of 210ml was generated inside the chamber. One patient was unable to complete the trial and the other three failed to develop significant enlargement of the original fat flap, which, at the time of chamber explantation, was encased in a thick fibrous capsule. Our study provides evidence that generation of large well-vascularized tissue engineered constructs using the TEC is feasible in humans. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Glazkov, S. A.; Gorbushin, A. R.; Osipova, S. L.; Semenov, A. V.
2016-10-01
The report describes the results of flow field experimental research in TsAGI T-128 transonic wind tunnel. During the tests Mach number, stagnation pressure, test section wall perforation ratio, angles between the test section panels and mixing chamber flaps varied. Based on the test results one determined corrections to the free-stream Mach number related to the flow speed difference in the model location and in the zone of static pressure measurement on the test section walls, nonuniformity of the longitudinal velocity component in the model location, optimal position of the movable test section elements to provide flow field uniformity in the test section and minimize the test leg drag.
Animal models in plastic and reconstructive surgery simulation-a review.
Loh, Charles Yuen Yung; Wang, Aline Yen Ling; Tiong, Vincent Tze Yang; Athanassopoulos, Thanassi; Loh, Meiling; Lim, Philip; Kao, Huang-Kai
2018-01-01
The use of live and cadaveric animal models in surgical training is well established as a means of teaching and improving surgical skill in a controlled setting. We aim to review, evaluate, and summarize the models published in the literature that are applicable to Plastic Surgery training. A PubMed search for keywords relating to animal models in Plastic Surgery and the associated procedures was conducted. Animal models that had cross over between specialties such as microsurgery with Neurosurgery and pinnaplasty with ear, nose, and throat surgery were included as they were deemed to be relevant to our training curriculum. A level of evidence and recommendation assessment was then given to each surgical model. Our review found animal models applicable to plastic surgery training in four major categories namely-microsurgery training, flap raising, facial surgery, and hand surgery. Twenty-four separate articles described various methods of practicing microsurgical techniques on different types of animals. Fourteen different articles each described various methods of conducting flap-based procedures which consisted of either local or perforator flap dissection. Eight articles described different models for practicing hand surgery techniques. Finally, eight articles described animal models that were used for head and neck procedures. A comprehensive summary of animal models related to plastic surgery training has been compiled. Cadaveric animal models provide a readily available introduction to many procedures and ought to be used instead of live models when feasible. Copyright © 2017 Elsevier Inc. All rights reserved.
Stübinger, Stefan; Saldamli, Belma; Seitz, Oliver; Sader, Robert; Landes, Constantin A
2009-05-01
The goal of this study was to compare the surgical advantages and disadvantages of a new palatal access osteotomy for sinus elevation with a conventional lateral approach. In 32 patients, either a palatal (n = 16) or a lateral (n = 16) osteotomy to the maxillary sinus was performed under local anesthesia. The palatal access included a circular paramarginal incision and elevation of a palatal mucosal flap based on a median pedicle. The lateral access was performed by vestibular standard incision and development of a mucoperiosteal flap with a vestibular and superior basis. For all osteotomies a piezoelectric device was used. The sinus cavity was augmented with synthetic nanostructured hydroxyapatite graft material. Intraoperative complications during both procedures were minimal and wound healing was uneventful. Membrane perforation occurred in 19% of the palatal group and in 19% of the lateral group. Soft tissue management of the palatal technique was superior to that of the lateral approach, because the vestibular anatomy was not altered and consequently no disharmonious soft tissue scarring and no postoperative swelling occurred. The palatal approach permitted higher postoperative comfort, especially for edentulous patients, because full dentures could be incorporated directly after surgery with almost perfect fit.
Rozen, Warren Matthew; Chowdhry, Muhammad; Patel, Nakul Gamanlal; Chow, Whitney T.H.; Griffiths, Matthew; Ramakrishnan, Venkat V.
2016-01-01
Background Venous couplers are ubiquitous around the world and are a useful tool for the reconstructive microsurgeon. A systematic review of coupler performance studies demonstrated a thrombosis rate range of 0% to 3%, whilst the average time of using the device is 5 minutes. There is sparse published data on cost analysis and the impact of operator experience on the anastomotic coupler device success. Improvements in outcomes other than time benefits have also not been shown. This study aims to address these deficiencies in the literature. Methods A retrospective clinical study was undertaken, aiming to compare equivalent groups of patients that had free flap surgery with venous micro-anastomoses with those that had sutured anastomoses. The cohort comprised all patients undergoing microsurgical breast reconstruction at the St Andrew’s Centre for Plastic Surgery & Burns from January 2009 to December 2014. Results Between January 2010 to December 2014, 1,064 patients underwent 1,206 free flap breast reconstructions. The average age of patients was 50 years. Seventy percent of patients underwent mastectomy and immediate reconstruction during this period with the remaining 30% having a delayed reconstruction. The 1,206 free flaps comprised of 83 transverse myocutaneous gracilis (TMG) flaps, and 1,123 deep inferior epigastric artery perforator (DIEP) flaps. In total the coupler was used in 319 flaps, 26% of the cohort. There was a statistically significant clinical benefit in using the anastomotic coupler for venous anastomosis. Overall, the return to theatre rate was 12.69% whilst the overall flap loss rate was 0.75%. The overall coupler failure rate was significantly less at 1.4% whilst sutured vein failure rate was 3.57% (P=0.001). Conclusions The anastomotic coupler for venous anastomosis in free flap surgery is associated with reduced operating times, reduced take-backs to theatre and cost benefits. This is the first study to demonstrate clear clinical benefits to anastomotic couplers, and suggests that these may be the gold standard for venous microanastomosis. With increasing experience with their use and technological advances, these outcomes may continue to improve. PMID:27047776
Peng, Hanwei; Wang, Steven J; Li, Weixiong
2014-10-11
The most common complications after thyroidectomy are injuries associated with the recurrent laryngeal nerve and parathyroid gland. Cervical esophagus perforation is an exceptionally rare complication after thyroidectomy; it can usually be resolved by conservative care. Cervical esophageal stenosis secondary to intraoperative esophageal injury during thyroidectomy is much rarer and has not been reported in the literature to date. We report a case of esophageal stenosis following thyroidectomy performed at a peripheral hospital. The patient initially underwent a thyroidectomy for papillary thyroid carcinoma involving the cervical esophagus; esophageal perforation was noted intraoperatively, and closed using three number 4 silk sutures. Cervical esophageal stenosis subsequently developed after conservative care. The patient was successfully treated with cervical esophagectomy and reconstruction using a tubed forearm free flap after a failed attempt at endoscopic recanalization. This case is discussed in conjunction with a review of the literature.
Burm, Jin Sik; Hwang, Jungil; Lee, Yung Ki
2018-04-01
Owing to the high recurrence rates of ischial pressure sores, surgeons should consider the possibility of future secondary flap surgery during flap selection. The purpose of this article is to present a new surgical option for the reconstruction of primary or recurrent ischial pressure sores using a simple hamstring-adductor magnus advancement flap and direct closure. After horizontal fusiform skin excision, complete bursa excision and ischiectomy were performed. The tenomuscular origin of the adductor magnus and the conjoined tenomuscular origin of the biceps femoris long head and semitendinosus were isolated and completely detached from the inferior border of the ischial tuberosity. They were then advanced in a cephalad direction without detachment of the distal tendon or muscle and securely affixed to the sacrotuberous ligament. The wound was directly closed without further incision or dissection. Twelve ischial pressure sores (6 primary and 6 recurrent; 12 patients) were surgically corrected. The follow-up period was 12 to 65 months. All patients healed successfully without early postoperative complications, such as hematoma, seroma, infection, wound dehiscence, or partial necrosis. Late complications included wound disruption 5 weeks after surgery that spontaneously healed in 1 case and recurrence 3 years later in another case. The new surgical option presented herein, which involves hamstring-adductor magnus advancement flap and direct closure, is a simple and reliable method for providing sufficient muscle bulk to fill the dead space and proper padding to the bone stump while preserving the main vascular perforators and pedicles as well as future surgical options.
Electrical burns of the abdomen.
Srivastava, Rakesh Kumar; Kumar, Ritesh
2013-09-01
A 35-year-old male farmer came in contact with 11,000 volts high tension electric wire and sustained full thickness burn wounds over scapula, upper limb and anterior abdominal wall along with perforation of the intestine. Patient was initially managed conservatively in general surgery ward and was referred to us after 3 days with necrosis of the burned skin and muscles over the shoulder and abdomen. Patient was initially managed conservatively and then thorough debridement of the necrotic skin over the left shoulder and upper arm was done and the area was split skin grafted. Patient developed enterocutaneous fistula, which healed over a period of 8 weeks. The granulating wound over the abdomen was also skin grafted and patient was discharged after 18 days. About 4 months, after the discharge patient presented with ventral hernia. Repair of ventral hernia by synthetic mesh application and reconstruction of the abdominal wall with a free tensor fascia lata flap was done over the mesh, but the flap failed. Then after debridement two random pattern transposition skin flaps, one from the right upper and another from the left lower abdomen were transposed over the abdominal wound and donor area was skin grafted. Patient was discharged after 17 days.
Ehanire, Tosan; Singhal, Dhruv; Mast, Bruce; Leyngold, Mark
2018-01-24
Microsurgery is performed using either the operating microscope or loupe magnification. Use of the operating microscope is considered the "criterion standard"; however, loupes are emerging as a safe and reliable technique to perform microsurgery. The purpose of this study was to analyze the safety of microsurgery under loupe magnification compared with the microscope. Previous studies discussing the safety of loupe magnification during microsurgery have been published; however, this is the first study to compare free flap outcomes from 2 surgeons at the same institution, each using their respective technique. The outcomes were compared by retrospective chart review of 116 patients, and 148 microvascular free tissue transfers were performed between January 1, 2013, and July 15, 2016, by 2 surgeons (D.S.) and (M.L.). Patients' demographics, free flap failure rate, and other surgical complications were analyzed. Statistical significance was determined by unpaired t test, and χ analysis was used to determine statistical significance in proportions between groups. Thirty-eight percent of flaps were performed under ×3.5 loupe magnification and 62% under the operating microscope. Most free flaps used were deep inferior epigastric perforator or muscle sparing transverse rectus abdominis flaps (52%) for breast reconstruction, remainder of free flaps included ALT, radial forearm, and latissimus dorsi for a variety of reconstructive applications. There was no significant difference between the loupes and microscope groups in intraoperative anastomotic revision rate (27% vs 17%), postoperative arterial or venous thrombosis (4.4% vs 2.6%, 5.4% vs 2.2%), flap loss (3.6% vs 2.2%), or median length of stay (6 days vs 6.5 days). The loupe magnification group had statistically significant shorter setup time (20 minutes, P < 0.01). Consistent with previously reported studies, we found no statistical difference in free flap outcomes and safety under loupe magnification compared with the operating microscope. This is the first study to demonstrate these findings with 2 microsurgeons both in their first 3 years in practice, with similar training and experience, operating at the same institution and given the same resources, each using either microscopes or loupes for microsurgery.
Simulation of plastic surgery and microvascular procedures using perfused fresh human cadavers.
Carey, Joseph N; Rommer, Elizabeth; Sheckter, Clifford; Minneti, Michael; Talving, Peep; Wong, Alex K; Garner, Warren; Urata, Mark M
2014-02-01
Surgical simulation models are often limited by their lack of fidelity, which hinders their essential purpose, making a better surgeon. Fresh cadaveric tissue is a superior model of simulation owing to its approximation of live tissue. One major unresolved difference between dead and live tissue is perfusion. Here, we propose a means of enhancing the fidelity of cadaveric simulation through the development of a perfused cadaveric model whereby simulation is further able to approach life-like surgery and teach one of the more technically demanding skills of plastic surgery: microsurgery. Fresh tissue human cadavers were procured according to university protocol. Perfusion was performed via cannulation of large vessels, and arterial and venous pressure was maintained by centrifugal circulation. Skin perfusion was evaluated with incisions in the perfused regions and was evaluated using indocyanine green angiography. Surgical simulations were selected to broadly evaluate applicability to plastic surgical education. Surgical simulation of 38 procedures ranging in complexity from skin excisions to microsurgical cases was performed with high priority given to the accurate simulation of clinical procedures. Flap dissections included perforator flaps, muscle flaps, and fasciocutaneous flaps. Effective perfusion was noted with ICG angiography and notable bleeding vessels. Microsurgical flap transfer was successfully performed. We report the establishment of a high fidelity surgical simulation using a perfused fresh tissue model in a realistic environment akin to the operating room. We anticipate utilization of this model prior to entering the operating room will enhance surgical ability and offer a valuable resource in plastic surgical education. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Breast Microsurgery in Plastic Surgery Literature: A 21-Year Analysis of Publication Trends
Daly, Lauren Tracy; Mowlds, Donald; Brodsky, Merrick A.; Abrouk, Michael; Gandy, Jessica R.; Wirth, Garrett A.
2018-01-01
Introduction Microsurgical reconstruction of the breast represents an area of continual evolution, as new autologous flaps are introduced and principles are refined. This progression can be demonstrated by bibliometric analysis of the scientific literature. Methods The top 10 plastic surgery journals were determined by impact factor (IF). Each issue of every journal from 1993 to 2013 was accessed directly, and all articles discussing microsurgery on the female breast were classified by authors’ geographic location, study design, and level of evidence (LOE, I–V). The productivity index and productivity share of each geographic region was calculated based on number of articles published and IF. Results A total of 706 breast microsurgery articles were analyzed. There was a significant increase in microsurgical breast research (p < 0.01), with an average 33.6 ± 31.1 articles per year and a mean increase of 4.4 articles per year. Most research was of lower LOE, with level I constituting 0.14% and level II constituting 5.21% of all articles. United States contributed the most research with 336.4 articles, followed by Western Europe with 242.2. However, Western Europe experienced the greatest increase in productivity share, with + 0.50 ± 0.29 growth, while United States demonstrated the greatest decrease in productivity share with − 1.23 ± 0.31 growth. Among autologous flaps, transverse rectus abdominis muscle research had the greatest yearly publication volume until 2002, when overtaken by deep inferior epigastric perforator flap research. Conclusion Over the 21-year study period, the United States not only contributed the greatest volume of research on female breast microsurgery but also demonstrated the greatest decline in research productivity. Efforts should be made to increase the LOE in breast microsurgery research. PMID:26645157
Hultman, Charles Scott; Friedstat, Jonathan S
2014-01-01
Who and what have been the most influential innovators and innovations in plastic surgery? This historical paper attempts to determine our most important contributors and contributions. We conducted an anonymous, 7-question, web-based survey of all members of the American Council of Academic Plastic Surgeons (ACAPS) and the Southeastern Society of Plastic and Reconstructive Surgeons (SESPRS). We asked respondents to list their top 5 most influential surgeons, the most important publications or bodies of work, and the most important innovations in plastic surgery, past and present. Of the 86 nominees from ACAPS, the 15 most influential surgeons of the past century were Tessier, Buncke, Murray, Millard, Gillies, Mathes, Jurkiewicz, Taylor, Converse, Blair, Kleinert, Edgerton, McCraw, Peacock, and Brown, in that order. The most 10 influential surgeons of the current era are Rohrich, McCarthy, Wei, Lee, Siemionow, Allen, Coleman, Guyuron, Serletti, and Nahai. Of the 112 nominees from SESPRS, the 15 most influential surgeons of the past century were Gillies, Millard, Tessier, Buncke, Murray, Jurkiewicz, Hartrampf, Mathes, Taylor, Bostwick, McCraw, Furlow, Converse, Peacock, and Blair, in that order. The 10 most influential surgeons of the current era are Rohrich, Nahai, Wei, McCarthy, Coleman, MacKinnon, McGrath, Rubin, Guyuron, and Hammond. Pooled from both lists, the 10 most influential publications or bodies of work were Hartrampf's TRAM flap, Millard's cleft lip repair, McCraw/Mathes/Nahai's myocutaneous flaps, Furlow's cleft palate repair, Tessier's cleft classification and craniofacial repairs, Ramirez's components separation, Buncke's replantation/toe-to-thumb transfer, McCarthy's mandibular distraction osteogenesis, Taylor's free flap and angiosome concepts, and Murray's kidney transplant. The top 10 innovations of the 20th century were myocutaneous flaps, microsurgery, craniofacial surgery, skin grafts, transplantation, liposuction, bioimplants, distraction osteogenesis, angiosome anatomy, and rigid fixation. The 10 most important, current innovations are hand/face transplantation, fat grafting, stem cells, neurotoxins and soft-tissue fillers, biologic scaffolds, information technology, tissue engineering and regenerative medicine, negative pressure wound therapy, perforator flaps, and noninvasive imaging. Plastic surgery includes a rich history of both incremental and disruptive innovation, which has endowed our discipline with a competitive advantage over other medical and surgical subspecialties. Based upon our past success in managing change, there may be no limit, or no line on the horizon, as to what is possible, provided that we pursue innovation in a systematic way that combines creativity and discipline.
NASA Technical Reports Server (NTRS)
Danforth, Richard A.
1991-01-01
Qualification of the full-scale process and design changes for elimination of redesigned solid rocket motor tang nitrile butadiene rubber insulation edge separations and voids was performed from 24 March to 3 December 1990. The objectives of this test were: to qualify design and process changes on flight hardware using a tie ply between the redesigned solid rocket motor steel case and the nitrile butadiene rubber insulation over the tang capture features; to qualify the use of methyl ethyl ketone in the tang flap region to reduce voids; and to determine if holes in the separator film reduce voids in the tang flap region. The tie ply is intended to aid insulation flow during the insulation cure process, and thus reduce or eliminate edge unbonds. Methyl ethyl ketone is intended to reduce voids in the tang flap area by providing better tacking characteristics. The perforated film was intended to provide possible vertical breathe paths to reduce voids in the tang area. Tang tie ply testing consisted of 270 deg of the tang circumference using a new layup method and 90 deg of the tang circumference using the current layup methods. Tie ply process success was defined as a reduction of insulation unbonds. Lack of any insulation edge unbonds on the tang area where the new process was used, and the presence of 17 unbonds with the current process, proves the test to be a success. Successful completion of this test has qualified the new processes.
Facial artery musculomucosal flap for reconstruction of skull base defects: a cadaveric study.
Xie, Liyue; Lavigne, François; Rahal, Akram; Moubayed, Sami Pierre; Ayad, Tareck
2013-08-01
Failure in skull base defects reconstruction following tumor resection can have serious consequences such as ascending meningitis and pneumocephaly. The nasoseptal flap showed a very low incidence of cerebrospinal fluid leak but is not always available. The superiorly pedicled facial artery musculomucosal (FAMM) flap has been successfully used for reconstruction of head and neck defects. Our objective is to show that the FAMM flap can be used as a new alternative in skull base reconstruction. Cadaveric study. Feasibility. Thirteen specimens underwent bilateral FAMM flap dissection. Two new modifications of the traditional FAMM flap have been developed. Feasibility in FAMM flap transfer to the skull base was investigated through endoscopic skull base dissection and maxillectomy in four specimens. Measurements were recorded for each harvested flap. The mean surface area of the modified FAMM flap efficient for reconstruction was 15.90 cm(2) . The flaps easily covered the simulated defects of the frontal sinus and the fovea ethmoidalis areas. Modifications of the traditional FAMM flap were necessary for a tension-free coverage of the planum sphenoidale and sella turcica. The FAMM flap holds high potential as a new alternative vascular flap in skull base reconstruction. However, it has not been used in patients yet and should be considered only when other options are not available. New modifications developed in this article can elongate the traditional FAMM flap, potentially contributing to a tighter seal of the skull base defect than FAMM flap alone. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.
Chen, Jiaying; Chen, Ying; Hu, Zhen; Liu, Guangyu; Shen, Zhenzhou; Shao, Zhimin; Wu, Jiong
2015-01-01
Background The goal of this study was to evaluate patient satisfaction with four common types of breast reconstruction performed at our institution: latissimus dorsi myocutaneous (LDM) flap reconstruction with or without implants, pedicled transverse rectus abdominis musculocutaneous (TRAM) flap reconstruction, and free deep inferior epigastric perforator (DIEP) flap reconstruction. Methods A custom survey consisting of questions that assessed general and aesthetic satisfaction was sent to patients who had undergone breast reconstruction in the last 5 years. The clinical data and details of the surgery were also collected from the patients who returned the surveys. We compared satisfaction rates across the four breast reconstruction types and analyzed the effects of various factors on overall general and aesthetic satisfaction rates using a binary logistic regression model. Result A total of 207 (72%) patients completed the questionnaires. Overall, significant differences in general and aesthetic satisfaction among the four procedures were not observed. A multivariate analysis revealed that the factor “complications” (p = 0.001) played a significant role in general satisfaction and that the factors “> 2 years since reconstruction” (p = 0.043) and “age > 35 years” (p = 0.05) played significant roles in overall aesthetic satisfaction. Conclusion The present study demonstrated that the type of breast reconstruction might not influence satisfaction in Chinese patients. PMID:26562294
Pedicled Extranasal Flaps in Skull Base Reconstruction
Kim, Grace G.; Hang, Anna X.; Mitchell, Candace; Zanation, Adam M.
2013-01-01
Cerebrospinal fluid (CSF) leaks most commonly arise during or after skull base surgery, although they occasionally present spontaneously. Recent advances in the repair of CSF leaks have enabled endoscopic endonasal surgery to become the preferred option for management of skull base pathology. Small defects (<1cm) can be repaired by multilayered free grafts. For large defects (>3cm), pedicled vascular flaps are the repair method of choice, resulting in much lower rates of postoperative CSF leaks. The pedicled nasoseptal flap (NSF) constitutes the primary reconstructive option for the vast majority of skull base defects. It has a large area of potential coverage and high rates of success. However, preoperative planning is required to avoid sacrificing the NSF during resection. In cases where the NSF is unavailable, often due to tumor involvement of the septum or previous resection removing or compromising the flap, other flaps may be considered. These flaps include intranasal options—inferior turbinate (IT) or middle turbinate (MT) flaps—as well as regional pedicled flaps: pericranial flap (PCF), temporoparietal fascial flap (TPFF), or palatal flap (PF). More recently, novel alternatives such as the pedicled facial buccinator flap (FAB) and the pedicled occipital galeopericranial flap (OGP) have been added to the arsenal of options for skull base reconstruction. Characteristics of and appropriate uses for each flap are described. PMID:23257554
Chong, Chew-Wei; Lin, Cheng-Hung; Lin, Yu-Te; Hsu, Chung-Chen; Chen, Shih-Heng
2018-04-01
We described a laterally based cross-finger flap for reconstruction of soft tissue defects in the fingers. This modification enables coverage of volar or dorsal soft tissue defects at the distal, middle or proximal phalanx. From March 2015 to January 2017, a total of 12 patients (13 fingers) underwent soft tissue reconstruction of the fingers with a laterally based cross-finger flap. The flap dimensions ranged from 13 ×7 mm to 43 ×13 mm. Eleven of the 13 flaps survived completely. The two flap failures were attributed to injuries in the donor fingers, rendering the blood supply of the flaps unreliable. All donor sites were closed primarily without the need for skin grafting, negating the problem of donor site morbidity that is associated with skin graft harvesting. The laterally based cross-finger flap is a versatile flap with less donor site morbidity and better aesthetics than a conventional cross-finger flap. We described the design of the flap, as well as the advantages and disadvantages, in doing a laterally based cross-finger flap. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Modern adjuncts and technologies in microsurgery: an historical and evidence-based review.
Pratt, George F; Rozen, Warren M; Chubb, Daniel; Whitaker, Iain S; Grinsell, Damien; Ashton, Mark W; Acosta, Rafael
2010-11-01
While modern reconstructive surgery was revolutionized with the introduction of microsurgical techniques, microsurgery itself has seen the introduction of a range of technological aids and modern techniques aiming to improve dissection times, anastomotic times, and overall outcomes. These include improved preoperative planning, anastomotic aides, and earlier detection of complications with higher salvage rates. Despite the potential for substantial impact, many of these techniques have been evaluated in a limited fashion, and the evidence for each has not been universally explored. The purpose of this review was to establish and quantify the evidence for each technique. A search of relevant medical databases was performed to identify literature providing evidence for each technology. Levels of evidence were thus accumulated and applied to each technique. There is a relative paucity of evidence for many of the more recent technologies described in the field of microsurgery, with no randomized controlled trials, and most studies in the field comprising case series only. Current evidence-based suggestions include the use of computed tomographic angiography (CTA) for the preoperative planning of perforator flaps, the intraoperative use of a mechanical anastomotic coupling aide (particularly the Unilink® coupler), and postoperative flap monitoring with strict protocols using clinical bedside monitoring and/or the implantable Doppler probe. Despite the breadth of technologies introduced into the field of microsurgery, there is substantial variation in the degree of evidence presented for each, suggesting the role for much future research, particularly from emerging technologies such as robotics and modern simulators. Copyright © 2010 Wiley-Liss, Inc.
Reconstruction Using Locoregional Flaps for Large Skull Base Defects.
Hatano, Takaharu; Motomura, Hisashi; Ayabe, Shinobu
2015-06-01
We present a modified locoregional flap for the reconstruction of large anterior skull base defects that should be reconstructed with a free flap according to Yano's algorithm. No classification of skull base defects had been proposed for a long time. Yano et al suggested a new classification in 2012. The lb defect of Yano's classification extends horizontally from the cribriform plate to the orbital roof. According to Yano's algorithm for subsequent skull base reconstructive procedures, a lb defect should be reconstructed with a free flap such as an anterolateral thigh free flap or rectus abdominis myocutaneous free flap. However, our modified locoregional flap has also enabled reconstruction of lb defects. In this case series, we used a locoregional flap for lb defects. No major postoperative complications occurred. We present our modified locoregional flap that enables reconstruction of lb defects.
Stanger, Katrin M; Albert, Frauke; Kneser, Ulrich; Bogdan, Christian; Horch, Raymund E
2015-08-01
We report the case of an 86-year-old man with severe wound infection originating from a chronic crural ulcer of the lower limb, which under negative pressure wound therapy led to excessive tissue necrosis and perforation of the anterior tibial artery. A swab taken 10 and 7 days preoperatively was positive for Helcococcus kunzii. H. kunzii has been described as a potentially pathogenic organism. The questions whether the negative pressure wound therapy itself caused the bleeding or the negative pressure wound therapy, which generates an anaerobic atmosphere, has triggered the growth and invasion of the facultative anaerobic bacterium H. kunzii and owing to the infection the artery perforated or whether the bacteria has no influence at all remain currently unanswered. After surgical debridement the signs of infection were completely eliminated, and a free musculocutaneous flap led to rapid healing of the wound. Following which H. kunzii was no longer detectable. © 2013 The Authors. International Wound Journal © 2013 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Chae, Michael P; Rozen, Warren Matthew; Patel, Nakul Gamanlal; Hunter-Smith, David J; Ramakrishnan, Venkat
2017-12-01
An increasing number of women undergo mastectomy for breast cancer and post-mastectomy autologous breast reconstruction has been shown to significantly improve the psychosexual wellbeing of the patients. A goal of treatment is to achieve symmetry and projection to match the native breast, and/or the contralateral breast in the case of a unilateral reconstruction. Autologous reconstruction, particularly with the deep inferior epigastric artery perforator (DIEP) flap, is particularly advantageous as it can be manipulated to mimic the shape and turgor of the native breast. However, very few techniques of shaping the breast conus when insetting the DIEP flap to enhance aesthetic outcome have been reported to date. With the aide of three-dimension (3D) photography and 3D-printed mirrored image of the contralateral breast as a guide intraoperatively, we describe our St Andrew's coning technique to create a personalized flap projection. We report a prospective case series of 3 delayed unilateral breast reconstructions where symmetrization procedure to the contralateral breast was not indicated. Using a commercial 3D scanner (VECTRA XR, Canfield Scientific), the breast region was imaged. The mirrored image was 3D-printed in-house using a desktop 3D printer. In all cases, projection of the breast mound was able to be safely achieved, with a demonstrated central volume (or 'cone') able to be highlighted on imaging and a 3D printed breast. A 3D print of the contralateral breast was able to be used intraoperatively to guide the operative approach. The St Andrew's coning technique is a useful aesthetic maneuver for achieving breast projection during DIEP flap breast reconstruction, with 3D imaging techniques able to assist in perioperative assessment of breast volume.
Chae, Michael P.; Patel, Nakul Gamanlal; Hunter-Smith, David J.; Ramakrishnan, Venkat
2017-01-01
Background An increasing number of women undergo mastectomy for breast cancer and post-mastectomy autologous breast reconstruction has been shown to significantly improve the psychosexual wellbeing of the patients. A goal of treatment is to achieve symmetry and projection to match the native breast, and/or the contralateral breast in the case of a unilateral reconstruction. Autologous reconstruction, particularly with the deep inferior epigastric artery perforator (DIEP) flap, is particularly advantageous as it can be manipulated to mimic the shape and turgor of the native breast. However, very few techniques of shaping the breast conus when insetting the DIEP flap to enhance aesthetic outcome have been reported to date. With the aide of three-dimension (3D) photography and 3D-printed mirrored image of the contralateral breast as a guide intraoperatively, we describe our St Andrew’s coning technique to create a personalized flap projection. Method We report a prospective case series of 3 delayed unilateral breast reconstructions where symmetrization procedure to the contralateral breast was not indicated. Using a commercial 3D scanner (VECTRA XR, Canfield Scientific), the breast region was imaged. The mirrored image was 3D-printed in-house using a desktop 3D printer. Results In all cases, projection of the breast mound was able to be safely achieved, with a demonstrated central volume (or ‘cone’) able to be highlighted on imaging and a 3D printed breast. A 3D print of the contralateral breast was able to be used intraoperatively to guide the operative approach. Conclusions The St Andrew’s coning technique is a useful aesthetic maneuver for achieving breast projection during DIEP flap breast reconstruction, with 3D imaging techniques able to assist in perioperative assessment of breast volume. PMID:29302489
Effect of marking pens on femtosecond laser-assisted flap creation.
Ide, Takeshi; Kymionis, George D; Abbey, Ashkan M; Yoo, Sonia H; Culbertson, William W; O'Brien, Terrence P
2009-06-01
To compare the ease of the flap lift after central corneal marking with 2 types of marking pens after femtosecond laser-assisted flap creation in laser in situ keratomileusis. Bascom Palmer Eye Institute, University of Miami, Miami, Florida, USA. Porcine eyes were prepared for flap creation with a femtosecond laser (IntraLase). The eyes were assigned to 1 of 4 groups. After the femtosecond laser treatment, the difficulty of flap lifting the 4 groups was compared. Twelve porcine eyes, 3 in each group, were evaluated. In the 2 groups in which an oil-based pen was used, the corneal flap could not be lifted. In the 2 groups in which a water-based pen was used, the corneal flap was easily lifted. Oil-based ink may reduce the ability of the femtosecond laser to penetrate the cornea. The resultant corneal flap may require aggressive manipulation to be lifted. When used to mark the center of the cornea before flap creation, water-based ink provided greater ease of corneal flap lifting than oil-based ink. Because the marking is located over the center of the pupil, any alteration of the cornea in this area from aggressive flap lifting may result in substantial visual loss. Therefore, the use of an oil-based ink to mark the central cornea must be avoided to prevent traumatic irregularities of the flap stroma.
Can, Anil; Orgill, Dennis P; Dietmar Ulrich, J O; Mureau, Marc A M
2014-12-01
Because the vascular anatomy of the trapezius flap is highly variable, choosing the most appropriate flap type and design is essential to optimize outcomes and minimize postoperative complications. The aim of this study was to develop a surgical treatment algorithm for trapezius flap transfers. The medical files of all consecutive patients with a myocutaneous trapezius flap reconstruction of the head, neck, and upper back area treated at three different university medical centers between July 2001 and November 2012 were reviewed. There were 43 consecutive flaps performed in 38 patients with a mean follow-up time of 15 months (range, 1-48 months). Eleven patients had a mentosternal burn scar contracture (12 flaps), 12 patients (13 flaps) presented with cancer, and 15 patients (18 flaps) were suffering from chronic wounds due to failed previous reconstruction (n = 6), osteoradionecrosis (n = 1), chronic infection (n = 3), bronchopleural fistula (n = 3), and pressure sores (n = 2). The mean defect size was 152 cm(2). Sixteen flaps were based on the superficial cervical artery (SCA; type 2), 16 were based on the dorsal scapular artery (DSA; type 3), one was based on the intercostal arteries (type 4), and 10 flaps were based on both the DSA and SCA. Recipient-site complications requiring reoperation occurred in 16.3%, including one total flap failure (2.6%). The trapezius myocutaneous flap is a valuable option to reconstruct various head and neck and upper back defects. Based on our data, a surgical treatment algorithm was developed in an attempt to reduce variation in care and improve clinical outcomes. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Venous Graft for Full-thickness Palpebral Reconstruction
Sanna, Marco Pietro Giuseppe; Maxia, Sara; Esposito, Salvatore; Di Giulio, Stefano; Sartore, Leonardo
2015-01-01
Summary: Full-thickness palpebral reconstruction is a challenge for most surgeons. The complex structures composing the eyelid must be reconstructed with care both for functional and cosmetic reasons. It is possible to find in literature different methods to reconstruct either the anterior or posterior lamella, based on graft or flaps. Most patients involved in this kind of surgery are elderly. It is important to use easy and fast procedures to minimize the length of the operation and its complications. In our department, we used to reconstruct the anterior lamella by means of a Tenzel or a Mustardé flap, whereas for the posterior lamella, we previously utilized a chondromucosal graft, harvested from nasal septum. Thus, these procedures required general anesthesia and long operatory time. We started using a vein graft for the posterior lamella. In this article, we present a series of 9 patients who underwent complex palpebral reconstruction for oncological reasons. In 5 patients (group A), we reconstructed the tarsoconjunctival layer by a chondromucosal graft, whereas in 4 patients (group B), we used a propulsive vein graft. The follow-up was from 10 to 20 months. The patient satisfaction was high, and we had no relapse in the series. In group A, we had more complications, including ectropion and septal perforations, whereas in group B, the operation was faster and we noted minor complications. In conclusion, the use of a propulsive vein to reconstruct the tarsoconjunctival layer was a reliable, safe, and fast procedure that can be considered in complex palpebral reconstructions. PMID:26034651
"Reading man flap" design for reconstruction of circular infraorbital and malar skin defects.
Seyhan, Tamer; Caglar, Baris
2008-11-01
Surgical complications such as lid retraction and ectropion from graft or flap scar contracture make reconstruction of skin defects in the malar and infraorbital regions challenging. A new flap design, the reading man flap, was used to overcome these problems. The Limberg and bilobed flap were compared with the reading man flap. The reading man flap consists mainly of a superiorly based quadrangular flap and an inferiorly based triangular flap. Malar and infraorbital circular skin defects measuring 14 x 14 to 40 x 40 mm were reconstructed with a reading man flap in 13 patients. The defects occurred after basal cell carcinoma in all patients. The Limberg flap, bilobed flap, and reading man flap were planned for same-sized defects on the abdominoplasty resection material. The results were compared in terms of total scar area, scar length, and total healthy skin area discarded. When comparing the 3 flap designs, the reading man flap was the most suitable flap in terms of total scar area and length. The reading man flap can be used to reconstruct malar and infraorbital circular defects with good cosmetic results and without creating any tractional forces to the eyelids.
van Veldhuisen, Charlotte L; Kamali, Parisa; Wu, Winona; Becherer, Babette E; Sinno, Hani H; Ashraf, Azra A; Ibrahim, Ahmed M S; Tobias, Adam; Lee, Bernard T; Lin, Samuel J
2017-12-01
Umbilical reconstruction is an important component of deep inferior epigastric perforator (DIEP) flap breast reconstruction. This study evaluated the aesthetics of three different umbilical reconstruction techniques during DIEP flap breast reconstruction. From January to April of 2013, a total of 29 consecutive patients undergoing DIEP flap breast reconstruction were randomized intraoperatively to receive one of three umbilicoplasty types: a diamond, an oval, or an inverted V incision. Independent plastic surgeons and members of the general public, identified using an online "crowdsourcing" platform, evaluated aesthetic outcomes in a blinded fashion. Reviewers were shown postoperative photographs of the umbilicus of all patients and a four-point Likert scale was used to rate the new umbilicus on the size, scar formation, shape, localization, and overall appearance. Results for the focus group of independent plastic surgeons and 377 members of the public were retrieved (n = 391). A total of 10 patients (34.5 percent) were randomized into having the diamond incision, 10 (34.5 percent) had the oval incision, and nine (31.0 percent) had the inverted V incision. Patients were well matched in terms of overall characteristics. The general public demonstrated a significant preference for the oval incision in all five parameters. There was no preference identified among surgeons. This study provides evidence that a sample of the U.S. general public prefers the aesthetics of the oval umbilicoplasty incision, which contrasted with the lack of preference identified within this focus group of plastic surgeons. Therapeutic, II.
Use of a nictitating membrane flap for treatment of feline acute corneal hydrops-21 eyes.
Pederson, Samantha L; Pizzirani, Stefano; Andrew, Stacy E; Pate, Diana O; Stine, Jessica M; Michau, Tammy M
2016-07-01
To evaluate the effectiveness of the use of a nictitating membrane flap (NMF) as therapy in 19 cats (21 eyes) affected with feline acute corneal hydrops (FACH). Medical records from 19 cats diagnosed with FACH and treated with a NMF were retrospectively evaluated. Information was collected from multiple veterinary hospitals and included signalment, medical history, therapy, and ocular outcome. Breeds included 13 Domestic Shorthairs, 2 Exotic Shorthairs, 2 Maine Coons, 1 Persian, and 1 Domestic Medium Hair. Two cats were bilaterally affected. Median age of cats was 3.2 years (range 0.26-15 years). Eleven patients were spayed females, 6 were neutered males, and 2 were intact males. Topical steroids were previously administered in 5 (23.8%) eyes; oral steroids were previously administered in 7 cats (36.8% of patients); three patients received both oral and topical steroids. Thirteen of 21 (61.9%) eyes had a history of ocular disease including ulcerative and nonulcerative keratitis, anterior uveitis, corneal sequestrum, conjunctivitis, and glaucoma. Median duration of NMF was 15 days (range 6-30 days). Follow-up ranged from 12 to 1601 days (median 169 days). Corneal perforation occurred in 1 (4.7%) eye and was successfully repaired. One lesion (4.7%) in a diabetic patient did not resolve. Nineteen of the treated eyes (90.5%) resolved with no complications. A nictitating membrane flap successfully treated 90.5% of FACH eyes (89.5% of patients). © 2016 American College of Veterinary Ophthalmologists.
Okada, Mitsuhiro; Ikeda, Mikinori; Uemura, Takuya; Takada, Jun; Nakamura, Hiroaki
2013-05-01
A propeller flap is useful for coverage of an adjacent skin defect without dissection back to source vessels and harvesting muscle tissues. The thoracoacromial artery is one of the vascular pedicles of the flaps for reconstruction in the cervical region. Use of a propeller flap based on the thoracoacromial artery has not previously been reported for reconstruction in the cervical region. We report a case in which a propeller flap based on the thoracoacromial artery was used for skin coverage after tumour resection in the cervical region together with an anatomical investigation. The propeller flap based on the thoracoacromial artery was harvested in the supine position, requiring no change in position after tumour resection. The skin defect was successfully reconstructed using the propeller flap based on the thoracoacromial artery with linear closure of the donor site. The propeller flap based on the thoracoacromial artery offers an alternative for reconstruction in the cervical region. Copyright © 2012 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Designing Hydrogel Adhesives for Corneal Wound Repair
Grinstaff, Mark W.
2013-01-01
Today, corneal wounds are repaired using nylon sutures. Yet there are a number of complications associated with suturing the cornea, and thus there is interest in an adhesive to replace or supplement sutures in the repair of corneal wounds. We are designing and evaluating corneal adhesives prepared from dendrimers – single molecular weight, highly branched polymers. We have explored two strategies to form these ocular adhesives. The first involves a photocrosslinking reaction and the second uses a peptide ligation reactions to couple the individual dendrimers together to from the adhesive. These adhesives were successfully used to repair corneal perforations, close the flap produced in a LASIK procedure, and secure a corneal transplant. PMID:17889330
Reconstructive Microsurgery: The Future Is Today.
Amin, Kavit; Mohan, Anita T
2017-01-01
This reconstructive microsurgery course will run yearly and was borne and popularized from its infant meeting the year before, primarily focused on perforator flaps. It is a 2-day course updating residents/registrars to attending physicians/consultants about the most topical advancements in microvascular reconstructive surgery. The course is held at the New York University Langone Hospital in the United States.The timetable is primarily lecture based with the advantage of live-surgical procedures by world-renowned faculty. The timetable includes, but not limited to, facial/hand vascularized composite allotransplantation, upper/lower limb, breast, head and neck, transgender, and lymphedema surgery. Lectures were highly informative and there was ample time for case discussion with the appreciation that managing complex situations often requires input from other colleagues. The faculty focused on the lessons they have learned and potential pitfalls to avoid. The faculty was comprised of leading experts in reconstructive microsurgery from Europe, Korea, and throughout the United States.The primary emphasis of the course was to appreciate the global recognition in advances in microsurgery.
Prevertebral corridor: posterior pathway for reconstruction of the ventral skull base.
Durmaz, Abdullah; Fernandez-Miranda, Juan; Snyderman, Carl H; Rivera-Serrano, Carlos; Tosun, Fuat
2011-05-01
Regional vascularized flaps, such as the pericranial and temporoparietal fascia flaps, are currently used for reconstruction of skull base defects after endoscopic endonasal surgery whenever local vascularized flaps, such as the nasoseptal flap, are not available. Two different transposition pathways, infratemporal transpterygoid and subfrontal, have been proposed for regional flaps. The objective of this study was to describe and assess the feasibility of the transposition of a vascularized pedicled flap from the occipital galeopericranium via the prevertebral space corridor into the nasopharynx. Ten heads were injected with colored silicone. An endoscopic endonasal anterior craniofacial resection and panclival approach were performed in each specimen. The occipital flap was harvested using a previously described technique. The prevertebral corridor, extending from the neck to the nasopharynx, was dissected superficial to the paraspinal muscles. Computed tomography-based image guidance was used to assess the relationship between the corridor and adjacent neurovascular structures. Length of the corridor and pedicle and area of the donor flap were measured. The flap was harvested and successfully transposed into the nasopharynx using the proposed corridor in all studied specimens (10 heads, 20 sides). All flaps provided complete coverage of the skull base defects. The average length of the pedicle was 70.5 (SD, 6.5) mm, and the average length and width of the flap were 99.9 (SD, 14.6) mm and 59.3 (SD, 10.9) mm, respectively. The average length of the prevertebral corridor was 49.7 (SD, 4.8) mm. The occipital flap has favorable anatomic characteristics for use in skull base reconstruction. Transposition of the flap via the prevertebral corridor is a suitable option for vascularized reconstruction of expanded endonasal skull base defects when other local or regional flaps are not available. Additional clinical studies are necessary to define its role in endoscopic endonasal surgery.
Ishii, Naohiro; Ando, Jiro; Harao, Michiko; Takemae, Masaru; Kishi, Kazuo
2018-05-07
In nipple reconstruction, the width, length, and thickness of modified star flaps are concerns for long-term reconstructed nipple projection. However, the flap's projection has not been analyzed, based on its thickness. The aim of the present study was to investigate how flap thickness in a modified star flap influences the resulting reconstructed nipple and achieves an appropriate flap width in design. Sixty-three patients who underwent nipple reconstruction using a modified star flap following implant-based breast reconstruction between August 2014 and July 2016 were included in this case-controlled study. The length of laterally diverging flaps was 1.5 times their width. The thickness of each flap was measured using ultrasonography, and the average thickness was defined as the flap thickness. We investigated the correlation between the resulting reconstructed nipple and flap thickness, and the difference of the change in the reconstructed nipple projection after using a thin or thick flap. The average flap thickness was 3.8 ± 1.7 (range 2.5-6.0) mm. There was a significant, linear correlation between the flap thickness and resulting reconstructed nipple projection (β = 0.853, p < 0.01). Furthermore, the difference between the thin and thick flaps in the resulting reconstructed nipple projection was significant (p < 0.01). Measuring the flap thickness preoperatively may allow surgeons to achieve an appropriate flap width; otherwise, alternative methods for higher projection might be used. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Maruccia, Michele; Fallico, Nefer; Cigna, Emanuele; Ciudad, Pedro; Nicoli, Fabio; Trignano, Emilio; Nacchiero, Eleonora; Giudice, Giuseppe; Ribuffo, Diego; Chen, Hung-Chi
2017-11-01
Clinical applications of ALT flap have currently extended to extremity (hand and foot) as well as oral cavity reconstruction. In these anatomical areas, the traditional harvesting technique presents a few disadvantages such as bulkiness of the recipient site and potential donor site morbidity including damage to the deep fascia and skin graft adhesions. The purpose of the present study was to compare the functional and aesthetic outcomes of upper and lower extremity reconstruction with either suprafascial or subfascial harvested anterolateral (ALT) flaps. Sixty patients who underwent hand or foot reconstruction with an ALT flap between January 2013 and January 2015 were included in the study (34 flaps elevated on a subfascial plane and 26 on a suprafascial plane). Group 1 (subfascial harvested ALT flap) was composed of 23 male and 11 female patients with an average age of 53.4 years (range, 36-72 years). Group 2 (suprafascial harvested ALT flap) was composed of 18 male and 8 female patients with an average age of 48.7 years (range, 32-69 years). Surgical indication was tumor resection for 20 patients in group 1 and 16 patients in group 2, chronic ulcer for 8 patients in group 1 and 6 patients in group 2, and trauma for 6 patients in group 1 and 4 patients in group 2. Complications were documented. Aesthetic outcomes were considered in terms of bulkiness of the recipient site, subsequent request for a debulking procedure, and donor site morbidity. Donor site scars were evaluated for cosmesis using a modified Hollander Wound Evaluation Scale (HWES). Skin grafts outcomes were assessed according to the modified Vancouver Scar Scale (VSS). Functional outcome at the recipient site was measured using the Enneking functional outcome score (ESS). Total range of motion (ROM) was recorded. All flaps were successfully elevated with at least one viable perforator with both approaches. The survival rates of suprafascial and subfascial harvested ALT flaps were 96.2 and 97% respectively (P = .85). The mean flap size was 110.4 ± 27.8 cm 2 in group 1 and 159.7 ± 44.4 cm 2 in group 2. The average flap thickness was 26.2± 5.2 mm in group 1 and 13.9 mm ± 4.1 in group 2. Complications included total flap loss (1 case in group 1 and 1 case in group 2), partial flap loss (2 cases in group 1 and 1 case in group 2), skin graft failure (3 cases in group 1), and muscle herniation at the donor site (1 case in group 1; P < .17). Secondary debulking procedures were needed for 20 flaps in the subfascial group and for one flap in the suprafascial group (P-value <.01). Donor site closure with skin grafts was necessary in 42 cases: 32 in group 1 and 10 in group 2. The suprafascial harvested ALT flap group reported a significant difference in terms of donor site morbidity. The HWES score of donor site scars was significantly lower in group 1 (mean 1.2 ± 0.54) than in group 2 (mean 2.4 ± 0.58), P < .01. Similarly, the VSS score for skin graft outcomes was lower in patients of group 1 (mean 4.5 ± 0.93) than in patients of group 2 (mean 6.7 ± 0.96), P < .01. There was also a significant lower score of postoperative ESS in patients of group 1 (mean 21.2 ± 3.4) when compared with patients of group 2 (mean 23.6 ± 2.7), P < .01. Total ROM improved on average 60° after surgery (P-value <.01). The suprafascial plane for elevating ALT flaps presented several advantages over the traditional subfascial approach in terms of functional and aesthetic outcomes, providing a thin flap allowing increased versatility to achieve better contour of flap, and minimizing the need for secondary debulking. © 2017 Wiley Periodicals, Inc.
Classification and Microvascular Flap Selection for Anterior Cranial Fossa Reconstruction.
Vargo, James D; Przylecki, Wojciech; Camarata, Paul J; Andrews, Brian T
2018-05-18
Microvascular reconstruction of the anterior cranial fossa (ACF) creates difficult challenges. Reconstructive goals and flap selection vary based on the defect location within the ACF. This study evaluates the feasibility and reliability of free tissue transfer for salvage reconstruction of low, middle, and high ACF defects. A retrospective review was performed. Reconstructions were anatomically classified as low (anterior skull base), middle (frontal bar/sinus), and high (frontal bone/soft tissue). Subjects were evaluated based on pathologic indication and goal, type of flap used, and complications observed. Eleven flaps in 10 subjects were identified and anatomic sites included: low ( n = 5), middle ( n = 3), and high ( n = 3). Eight of 11 reconstructions utilized osteocutaneous flaps including the osteocutaneous radial forearm free flap (OCRFFF) ( n = 7) and fibula ( n = 1). Other reconstructions included a split calvarial graft wrapped within a temporoparietal fascia free flap ( n = 1), latissimus myocutaneous flap ( n = 1), and rectus abdominis myofascial flap ( n = 1). All 11 flaps were successful without microvascular compromise. No complications were observed in the high and middle ACF defect groups. Two of five flaps in the low defect group using OCRFFF flaps failed to achieve surgical goals despite demonstrating healthy flaps upon re-exploration. Complications included persistent cerebrospinal fluid leak ( n = 1) and pneumocephalus ( n = 1), requiring flap repositioning in one subject and a second microvascular flap in the second subject to achieve surgical goals. In our experience, osteocutaneous flaps (especially the OCRFFF) are preferred for complete autologous reconstruction of high and middle ACF defects. Low skull base defects are more difficult to reconstruct, and consideration of free muscle flaps (no bone) should be weighed as an option in this anatomic area. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Ludolph, Ingo; Arkudas, Andreas; Schmitz, Marweh; Boos, Anja M; Taeger, Christian D; Rother, Ulrich; Horch, Raymund E; Beier, Justus P
2016-10-01
The aim of this prospective study was to assess the correlation of flap perfusion analysis based on laser-assisted Indocyanine Green (ICG) angiography with combined laser Doppler spectrophotometry in autologous breast reconstruction using free DIEP/ms-TRAM flaps. Between February 2014 and July 2015, 35 free DIEP/ms-TRAM flaps were included in this study. Besides the clinical evaluation of flaps, intraoperative perfusion dynamics were assessed by means of laser-assisted ICG angiography and post-capillary oxygen saturation and relative haemoglobin content (rHb) using combined laser Doppler spectrophotometry. Correlation of the aforementioned parameters was analysed, as well as the impact on flap design and postoperative complications. Flap survival rate was 100%. There were no partial flap losses. In three cases, flap design was based on the angiography, contrary to clinical evaluation and spectrophotometry. The final decision on the inclusion of flap areas was based on the angiographic perfusion pattern. Angiography and spectrophotometry showed a correlation in most of the cases regarding tissue perfusion, post-capillary oxygen saturation and relative haemoglobin content. Laser-assisted ICG angiography is a useful tool for intraoperative evaluation of flap perfusion in autologous breast reconstruction with DIEP/ms-TRAM flaps, especially in decision making in cases where flap perfusion is not clearly assessable by clinical signs and exact determination of well-perfused flap margins is difficult to obtain. It provides an objective real-time analysis of flap perfusion, with high sensitivity for the detection of poorly perfused flap areas. Concerning the topographical mapping of well-perfused flap areas, laser-assisted angiography is superior to combined laser Doppler spectrophotometry. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Wright, Thomas C; Mossaad, Bassem M; Chummun, Shaheel; Khan, Umraz; Chapman, Thomas W L
2013-07-01
The proximally pedicled medial plantar flap is well described for coverage of wounds around the ankle and heel. This flap is usually based on the deep venae comitantes for venous drainage, with the superficial veins divided during dissection. Usually any disruption of the deep venous system of the flap would result in abandoning this choice of flap. Venous congestion is a recognised complication of medial plantar flaps. The patient described in this case report had a medial ankle defect with exposed bone, for which a proximally pedicled medial plantar flap was used. As we raised the flap, both venae comitantes of the medial planter artery were found to be disrupted. The flap was raised based on the superficial veins draining into the great saphenous, as the only system for venous drainage, with no evidence of venous congestion. The flap was successfully transposed into the defect and healed with no complications. The proximally pedicled medial plantar flap can safely rely on the superficial venous system alone for drainage. In addition, preserving the superficial veins minimise the risk of venous congestion in this flap. We recommend preservation of superficial venous system when possible. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Distally based posterior interosseous flap: primary role in soft-tissue reconstruction of the hand.
Agir, Hakan; Sen, Cenk; Alagöz, Sahin; Onyedi, Murat; Isil, Eda
2007-09-01
A series of 15 consecutive patients with various hand defects requiring flap coverage was reviewed in this study. The defects were all covered with the distally based posterior interosseous flap. Its main indications were in complex hand trauma, severe burn injury, or skin cancer ablation, either acute or postprimary. In 12 of the patients, flaps survived completely. In 3 patients, there was partial necrosis of the distal part of the flap, which did not require additional surgical procedure. Radial nerve palsy was noted in one of the cases, with a complete recovery after 3 months. Donor site was closed directly in up to 4-cm-wide flaps, while larger flaps required skin grafting. No major anatomic variation was observed. Distally based posterior interosseous flap is a reliable choice for various types and areas of hand defects, with very low donor-site morbidity, and should be more commonly considered in clinical practice.
Beustes-Stefanelli, Matthieu; O'Toole, Greg; Schertenleib, Pierre
2015-04-01
Nasolabial flaps based on the lateral side of the nose for the reconstruction of lateral nasal defects in a single-stage procedure have been described. Similarly, in midline defects, nasolabial flaps can be used but a 2-stage procedure is classically required. The Midline-based Nasolabial Transposition (MNT) flap is presented as a new single-stage procedure for nasal tip reconstruction. Between 2009 and 2011, an MNT flap was used as a single-stage procedure in 3 cases of large nasal defects of the tip where the forehead flap was either contraindicated or rejected as an option by the patient. There were no complications and a satisfactory aesthetic result was achieved in all cases. The MNT flap is a new single-stage procedure for large nasal tip defects and as such represents an interesting alternative to the classical 2-stage forehead and nasolabial flaps, especially in elderly patients.
Zhang, Jian; Huang, Jian; Pan, Jiadong; Zhou, Danya; Yin, Shanqing; Li, Junjie; Wang, Xin
2017-03-01
To explore the causes of vascular crisis after thumb and other finger reconstruction by toe-to-hand transfer and effective treatment methods so as to improve the survival rate of transplanted tissues. Between February 2012 and October 2015, 59 cases of thumb and other finger defects were repaired with different hallux nail flaps with the same vascular pedicle flap to reconstruct thumb and other fingers and repair skin defect. The donor site was repaired by a perforator flap. A total of 197 free tissues were involved. There were 46 males and 13 females with the average age of 30.6 years (range, 18-42 years). Vascular crisis occurred in 21 free tissues (10.7%) of 17 patients, including 9 arterial crisis (4.6%) of 8 cases, and 12 venous crisis (6.1%) of 10 cases. Conservative treatment was performed first; in 8 free tissues of 7 cases after failure of conservative treatment, anastomotic thrombosis was found in 5 free tissues of 4 cases, twisted vascular pedicle in 1 free tissue of 1 case, surrounding hematoma in 1 free tissue of 1 case, and anastomotic thrombosis associated with hematoma in 1 free tissue of 1 case, which underwent clearing hematoma, resecting embolization, regulating vascular tension, re-anastomosis or vascular transplantation. In 8 cases of arterial crisis, 5 free tissues of 5 cases survived after conservative treatment; partial necrosis occurred in 1 free tissue (1 case) of 4 free tissues (3 cases) undergoing surgical exploration. In 10 cases of venous crisis, 1 free tissue necrosis and 1 free tissue partial necrosis occurred in 8 free tissues (6 cases) undergoing conservative treatment; partial necrosis occurred in 1 free tissue of 4 free tissues (4 cases) undergoing surgical exploration. Free flap and skin graft were performed on 2 free tissues of 4 cases having flap necrosis respectively. Vascular crisis is complex and harmful to survival of transplanted tissue in reconstruction of the thumb and other fingers. Immediate intervention is helpful to obtain a higher survival rate.
Experimental study on thrust and power of flapping-wing system based on rack-pinion mechanism.
Nguyen, Tuan Anh; Vu Phan, Hoang; Au, Thi Kim Loan; Park, Hoon Cheol
2016-06-20
This experimental study investigates the effect of three parameters: wing aspect ratio (AR), wing offset, and flapping frequency, on thrust generation and power consumption of a flapping-wing system based on a rack-pinion mechanism. The new flapping-wing system is simple but robust, and is able to create a large flapping amplitude. The thrust measured by a load cell reveals that for a given power, the flapping-wing system using a higher wing AR produces larger thrust and higher flapping frequency at the wing offset of 0.15[Formula: see text] or 0.20[Formula: see text] ([Formula: see text] is the mean chord) than other wing offsets. Of the three parameters, the flapping frequency plays a more significant role on thrust generation than either the wing AR or the wing offset. Based on the measured thrusts, an empirical equation for thrust prediction is suggested, as a function of wing area, flapping frequency, flapping angle, and wing AR. The difference between the predicted and measured thrusts was less than 7%, which proved that the empirical equation for thrust prediction is reasonable. On average, the measured power consumption to flap the wings shows that 46.5% of the input power is spent to produce aerodynamic forces, 14.0% to overcome inertia force, 9.5% to drive the rack-pinion-based flapping mechanism, and 30.0% is wasted as the power loss of the installed motor. From the power analysis, it is found that the wing with an AR of 2.25 using a wing offset of 0.20[Formula: see text] showed the optimal power loading in the flapping-wing system. In addition, the flapping frequency of 25 Hz is recommended as the optimal frequency of the current flapping-wing system for high efficiency, which was 48.3%, using a wing with an AR of 2.25 and a wing offset of 0.20[Formula: see text] in the proposed design.
Effect of topically applied minoxidil on the survival of rat dorsal skin flap.
Gümüş, Nazım; Odemiş, Yusuf; Yılmaz, Sarper; Tuncer, Ersin
2012-12-01
Flap necrosis still is a challenging problem in reconstructive surgery that results in irreversible tissue loss. This study evaluated the effect of topically applied minoxidil on angiogenesis and survival of a caudally based dorsal rat skin flap. For this study, 24 male Wistar rats were randomly divided into three groups of eight each. A caudally based dorsal skin flap with the dimensions of 9 × 3 cm was raised. After elevation of the flaps, they were sutured back into their initial positions. In group 1 (control group), 1 ml of isotonic saline was applied topically to the flaps of all the animals for 14 days. In group 2, minoxidil solution was spread uniformly over the flap surface for 7 days after the flap elevation. In group 3, minoxidil solution was applied topically to the flap surface during a 14-day period. On day 7 after the flap elevation, the rats were killed. The average area of flap survival was determined for each rat. Subdermal vascular architecture and angiogenesis were evaluated under a light microscope after two full-thickness skin biopsy specimens had been obtained from the midline of the flaps. The lowest flap survival rate was observed in group 1, and no difference was observed between groups 1 and 2. Compared with groups 1 and 2, group 3 had a significantly increased percentage of flap survival (P < 0.05). Intense and moderate angiogenesis also was observed respectively at the proximal and distal areas of the flaps in group 3. The results of this experiment seem to show that the early effect of minoxidil is vasodilation and that prolonged use before flap elevation leads to angiogenesis, increasing flap viability. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Timmermans, Floyd W; Westland, Pèdrou B; Hummelink, Stefan; Schreurs, Joep; Hameeteman, Marijn; Ulrich, Dietmar J O; Slater, Nicholas J
2018-06-01
The deep inferior epigastric artery perforator (DIEP) flap is one of the most common techniques for breast reconstruction. Body mass index (BMI) is considered as an important predictor of donor site healing complications such as wound dehiscence. The use of computed tomography (CT) proved to be a precise and objective method to assess visceral adipose tissue. It remains unclear whether quantification of visceral fat provides more accurate predictions of abdominal wound healing complications than BMI. A total of 97 patients with DIEP flap were retrospectively evaluated. Patients' abdominal visceral fat (AVF) was quantified on CT angiography (CTA). The patients were postoperatively assessed for abdominal wound healing complications. We analyzed for the correlations between AVF, BMI, and dehiscence and established a logistic regression model to assess the potential high-profile predictors in anatomic and patient characteristics such as weight, smoking, and diabetes. We included 97 patients, and of them, 24 patients (24.7%) had some degree of abdominal dehiscence. No significant differences were observed between the dehiscence group and the non-dehiscence group, except for smoking (p = 0.002). We found a significant correlation between AVF and BMI (R = 0.282, p = 0.005), but neither was significant in predicting donor site dehiscence. Smoking greatly increased the likelihood of developing wound dehiscence (OR = 11.4, p = < 0.001). AVF and BMI were not significant predictors of abdominal wound healing complications after DIEP flap reconstruction. This study established active smoking (OR = 11.4, p = < 0.001) as the significant risk factor that contributed to the development of abdominal wound dehiscence in patients with DIEP. Copyright © 2018 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Feasibility and Advantages of Full Thickness Skin Graft from the Anterolateral Thigh.
Shin, Seung-Han; Kim, Chulkyu; Lee, Yong-Suk; Kang, Jin-Woo; Chung, Yang-Guk
2017-12-01
Full thickness skin graft (FTSG) gives better outcomes than split thickness skin graft (STSG), but it has the drawback of limited donor sites. Anterolateral thigh (ALT), a popular donor site of STSG, is also a popular donor site of perforator flaps. This area has the advantage of large flap size available with primary closure. Based on this we harvested FTSG instead of STSG from the ALT. We retrospectively reviewed 10 cases of FTSG from the ALT, with the recipient site of foot in 3, ankle in 2, lower leg in 2, forearm in 2, and wrist in 1 patient. In all cases elliptical full thickness skin was harvested from the ALT, and the donor site was closed primarily. The skin was defatted and placed onto the defect with vacuum-assisted closure (VAC). The skin size ranged 7-30 cm in length and 3-12 cm in width. Mean follow up period was 7 months (range, 3-13). FTSG from the ALT provided durable wound coverage, with excellent color and texture matching. Partial (< 20%) graft failure was observed in 1 case, but no additional surgery was necessary. No patient reported donor site pain at postoperative 2 weeks. No donor site complications were encountered. No patient complained a feeling of tension in the thigh at final follow-up. FTSG from the ALT is feasible with the aid of VAC. Considering the skin quality, large skin size available, early pain relief, and little donor site morbidity, the ALT should be revisited as a donor site of FTSG.
Highest Impact Articles in Microsurgery: A Citation Analysis.
Kim, Kuylhee; Ibrahim, Ahmed M S; Koolen, Pieter G L; Markarian, Mark K; Lee, Bernard T; Lin, Samuel J
2015-09-01
Microsurgery has developed significantly since the inception of the first surgical microscope. There have been few attempts to describe "classic" microsurgery articles. In this study citation analysis was done to identify the most highly cited clinical and basic science articles published in five peer-reviewed plastic surgery journals. Thomson/Reuters web of knowledge was used to identify the most highly cited microsurgery articles from five journals: Plastic and Reconstructive Surgery, Annals of Plastic Surgery, Journal of Plastic, Reconstructive & Aesthetic Surgery, Journal of Reconstructive Microsurgery, and Microsurgery. Articles were identified and sorted based on the number of citations and citations per year. The 50 most cited clinical and basic science articles were identified. For clinical articles, number of total citations ranged from 120 to 691 (mean, 212.38) and citations per year ranged from 30.92 to 3.05 (mean, 9.33). The most common defect site was the head and neck (n = 15, 30%), and flaps were perforator and muscle/musculocutaneous flaps (n = 10 each, 20%, respectively). For basic science articles, number of citations ranged from 71 to 332 (mean, 130.82) and citations per year ranged from 2.20 to 11.07 (mean, 5.27). There were 27 animal, 21 cadaveric, and 2 combined studies. The most highly cited microsurgery articles are a direct reflection of the educational and clinical trends. Awareness of the most frequently cited articles may serve as a basis for core knowledge in the education of plastic surgery trainees. III. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Tarantino, Mary E; Bilotti, Katharina; Huang, Ji; Delaney, Sarah
2015-08-21
Flap endonuclease 1 (FEN1) is a structure-specific nuclease responsible for removing 5'-flaps formed during Okazaki fragment maturation and long patch base excision repair. In this work, we use rapid quench flow techniques to examine the rates of 5'-flap removal on DNA substrates of varying length and sequence. Of particular interest are flaps containing trinucleotide repeats (TNR), which have been proposed to affect FEN1 activity and cause genetic instability. We report that FEN1 processes substrates containing flaps of 30 nucleotides or fewer at comparable single-turnover rates. However, for flaps longer than 30 nucleotides, FEN1 kinetically discriminates substrates based on flap length and flap sequence. In particular, FEN1 removes flaps containing TNR sequences at a rate slower than mixed sequence flaps of the same length. Furthermore, multiple-turnover kinetic analysis reveals that the rate-determining step of FEN1 switches as a function of flap length from product release to chemistry (or a step prior to chemistry). These results provide a kinetic perspective on the role of FEN1 in DNA replication and repair and contribute to our understanding of FEN1 in mediating genetic instability of TNR sequences. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.
Gümüş, Nazım; Odemiş, Yusuf; Tuncer, Ersin; Yılmaz, Sarper
2013-08-01
The purpose of this study was to determine the effectiveness of topically applied minoxidil in the pharmacological delay phenomenon and to demonstrate the comparable microscopic and macroscopic changes between minoxidil-pretreated flaps and surgically delayed flaps. A modified version of the McFarlane flap was used. Group 1 rats, in which a caudally based dorsal skin flap was raised and sutured back, were the control group. In group II, minoxidil solution was spread over the marked skin flap area for 7 days. On the 7th day, a caudally based dorsal skin flap was elevated and then sutured back. Group III rats underwent a surgical delay procedure alone. On the 7th day after flap elevation, evaluation was done by histologic examination and calculation of the flap survival areas in all groups. The lowest flap survival rate appeared in group I and was statistically different from groups II and III. The mean surviving skin flap area in the minoxidil-pretreated group was significantly larger than that in the control group. After histologic evaluation, moderate angiogenesis was also detected in group II. We also found that surgical delay significantly reduced flap necrosis when compared to the minoxidil pretreatment group. According to our study, minoxidil may be considered an effective vasoactive agent for the stimulation of angiogenesis in rat cutaneous flaps and capable of achieving pharmacological delay and increasing flap survival. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Reading, G
1984-12-01
The instep island flap is safe and useful. It is based on branches of the posterior tibial artery and can be a musculocutaneous or a direct fasciocutaneous island flap. Sensory branches of the digital nerves may be transposed with the flap. There is a wide arc of transposition and the flap has survived even in very difficult circumstances.
A lining vomer flap for palate pushback in unilateral cleft palate repair.
Clavin, H D; Owsley, J Q
1978-01-01
A combinaation vomer mucoperiosteal flap and nasal floor mucoperiosteal flap is described which is used to achieve nasal coverage in unilateral cleft palate patients requiring pushbacks. A posteriorly based readily accessible vomer flap is raised on the cleft side and used as nasal lining for the palatal mucoperiosteal flap on the non-cleft side. On the cleft side, a symmetrically sized nasal floor flap is easily elevated under direct vision and used to cover the nasal aspect of the corresponding mucoperiosteal palatal flap.
Dolci, Ricardo Landini Lutaif; Todeschini, Alexandre Bossi; Santos, Américo Rubens Leite Dos; Lazarini, Paulo Roberto
2018-04-19
One of the main concerns in endoscopic endonasal approaches to the skull base has been the high incidence and morbidity associated with cerebrospinal fluid leaks. The introduction and routine use of vascularized flaps allowed a marked decrease in this complication followed by a great expansion in the indications and techniques used in endoscopic endonasal approaches, extending to defects from huge tumours and previously inaccessible areas of the skull base. Describe the technique of performing endoscopic double flap multi-layered reconstruction of the anterior skull base without craniotomy. Step by step description of the endoscopic double flap technique (nasoseptal and pericranial vascularized flaps and fascia lata free graft) as used and illustrated in two patients with an olfactory groove meningioma who underwent an endoscopic approach. Both patients achieved a gross total resection: subsequent reconstruction of the anterior skull base was performed with the nasoseptal and pericranial flaps onlay and a fascia lata free graft inlay. Both patients showed an excellent recovery, no signs of cerebrospinal fluid leak, meningitis, flap necrosis, chronic meningeal or sinonasal inflammation or cerebral herniation having developed. This endoscopic double flap technique we have described is a viable, versatile and safe option for anterior skull base reconstructions, decreasing the incidence of complications in endoscopic endonasal approaches. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
NASA Astrophysics Data System (ADS)
Xie, Lingwang; Zhang, Xingwei; Luo, Pan; Huang, Panpan
2017-10-01
The optimization designs and dynamic analysis on the driving mechanism of flapping-wing air vehicles on base of flapping trajectory patterns is carried out in this study. Three different driving mechanisms which are spatial double crank-rocker, plane five-bar and gear-double slider, are systematically optimized and analysed by using the Mat lab and Adams software. After a series debugging on the parameter, the comparatively ideal flapping trajectories are obtained by the simulation of Adams. Present results indicate that different drive mechanisms output different flapping trajectories and have their unique characteristic. The spatial double crank-rocker mechanism can only output the arc flapping trajectory and it has the advantages of small volume, high flexibility and efficient space utilization. Both planar five-bar mechanism and gear-double slider mechanism can output the oval, figure of eight and double eight flapping trajectories. Nevertheless, the gear-double slider mechanism has the advantage of convenient parameter setting and better performance in output double eight flapping trajectory. This study can provide theoretical basis and helpful reference for the design of the drive mechanisms of flapping-wing air vehicles with different output flapping trajectories.
[Pedicle flaps based on the sphenopalatine artery: anatomical and surgical study].
Gras-Cabrerizo, Juan R; Gras-Albert, Juan R; Monjas-Canovas, Irene; García-Garrigós, Elena; Montserrat-Gili, Joan R; Sánchez del Campo, Francisco; Kolanczak, Katarzyna; Massegur-Solench, Humbert
2014-01-01
Local pedicle flaps based on the sphenopalatine artery make it possible to reconstruct large defects of the skull base (SB). From January 2008 to January 2013, 64 lesions with involvement of SB were analysed. These lesions were treated using endoscopic endonasal approach and required a pedicle flap based on the sphenopalatine artery. In addition, measurements and flexibility of the flaps were examined in 4 cadaveric nasal cavities. Surgical group. Sixty-four nasoseptal flaps (NSF) were used, in 4 cases associated with a middle turbinate flap (MTF), and in 1 case supplemented with an inferior turbinate flap (ITF). Five cerebrospinal fluid fistulas (8%) were noted. Among patients with initial lesions, 7% presented an anosmia. Cadaveric group. The length of the NSF varied between 5.2 cm and 7.7 cm and the width ranged from 3 cm to 4.5 cm. The ITF provided an anterior-posterior distance between 4.2 cm and 5 cm, with a width between 1.2 cm and 2.8 cm. The mean length of MTFs varied between 3.5 cm and 4.2 cm, with a width between 1.4 cm and 1.9 cm. The most versatile local flap for the reconstruction of skull base defects is the NSF, and flaps pedicled to the posterolateral nasal artery offer an excellent alternative. Copyright © 2013 Elsevier España, S.L. y Sociedad Española de Otorrinolaringología y Patología Cérvico-Facial. All rights reserved.
Mikami, Taro; Kaida, Eriko; Yabuki, Yuichiro; Kitamura, Sho; Kokubo, Ken'ichi; Maegawa, Jiro
2018-03-28
The distally based sural flap is regarded as the first choice for reconstruction in the distal part of the lower leg because the flap is easy to raise, reliable in its blood supply, and prone to only a few complications. Limited data have investigated the details of treatment in cases of failure of distally based sural flaps. We report a case of calcaneal osteomyelitis in which a successful outcome was finally obtained with a partially necrosed, distally based sural flap using negative pressure wound therapy with basic fibroblast growth factor spray. The 2-year follow-up examination was uneventful. Moreover, the patient was able to walk freely with an ankle-foot orthosis in her house. This technique can be considered as a useful and effective option to recover unfavorable results of distally based sural flaps. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Zhou, Renpeng; Wang, Chen; Qian, Yunliang; Wang, Danru
2015-09-01
Facial defects are multicomponent deficiencies rather than simple soft-tissue defects. Based on different branches of the superficial temporal vascular system, various tissue components can be obtained to reconstruct facial defects individually. From January 2004 to December 2013, 31 patients underwent reconstruction of facial defects with composite flaps based on the superficial temporal vascular system. Twenty cases of nasal defects were repaired with skin and cartilage components, six cases of facial defects were treated with double island flaps of the skin and fascia, three patients underwent eyebrow and lower eyelid reconstruction with hairy and hairless flaps simultaneously, and two patients underwent soft-tissue repair with auricular combined flaps and cranial bone grafts. All flaps survived completely. Donor-site morbidity is minimal, closed primarily. Donor areas healed with acceptable cosmetic results. The final outcome was satisfactory. Combined flaps based on the superficial temporal vascular system are a useful and versatile option in facial soft-tissue reconstruction. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Distant Pedicle Flaps for Soft Tissue Coverage of Severely Burned Hands: An Old Idea Revisited
2001-09-01
choice remains immedi- Fig. 2. Groin flap. Groin flap revision with liposuction . D.J. Barillo et al. / Burns 27 (2001) 613–619 617 Fig. 2. (Continued...to cover hand defects. Secondary liposuction procedures are effec- tive in debulking the flap. The Tensor Fascia Lata Flap (TFL) is based upon the
Hanson, M; Patel, P M; Betz, C; Olson, S; Panizza, B; Wallwork, B
2015-07-01
To assess nasal morbidity resulting from nasoseptal flap use in the repair of skull base defects in endoscopic anterior skull base surgery. Thirty-six patients awaiting endoscopic anterior skull base surgery were prospectively recruited. A nasoseptal flap was used for reconstruction in all cases. Patients were assessed pre-operatively and 90 days post-operatively via the Sino-Nasal Outcome Test 20 questionnaire and visual analogue scales for nasal obstruction, pain, secretions and smell; endoscopic examination findings and mucociliary clearance times were also recorded. Sino-Nasal Outcome Test 20 questionnaire data and visual analogue scale scores for pain, smell and secretions showed no significant differences between pre- and post-operative outcomes, with visual analogue scale scores for nasal obstruction actually showing a significant improvement (p = 0.0007). A significant deterioration for both flap and non-flap sides was demonstrated post-operatively on endoscopic examination (p = 0.002 and p = 0.02 respectively). Whilst elevation of a nasoseptal flap in endoscopic surgery of the anterior skull base engendered significant clinical deterioration on examination post-operatively, quality of life outcomes showed that no such deterioration was subjectively experienced by the patient. In fact, there was significant nasal airway improvement following nasoseptal flap reconstruction.
The inferior turbinate flap in skull base reconstruction
2013-01-01
Background As the indications for expanded endonasal approaches continue to evolve, alternative reconstructive techniques are needed to address increasingly complex surgical skull base defects. In the absence of the nasoseptal flap, we describe our experience with the posterior pedicle inferior turbinate flap (PPITF) in skull base reconstruction. Design Case series. Setting Academic tertiary care centre. Methods Patients who underwent reconstruction of the skull base with the PPITF were identified. Medical records were reviewed for demographic, presentation, treatment, follow-up, surgical and outcomes data. Main outcome measures Flap survival, adequacy of seal, and complications. Results Two patients with residual/recurrent pituitary adenomas met the inclusion criteria. The nasoseptal flap was unavailable in each case due to a prior septectomy. Salvage of the original nasoseptal flap was not possible, as it did not provide adequate coverage of the resultant defect due to contraction from healing. All PPITFs healed uneventfully and covered the entire defect. No complications were observed in the early post-operative period. Endoscopic techniques and limitations of the PPITF are also discussed. Conclusions Our clinical experience supports the PPITF to be a viable alternative for reconstruction of the skull base in the absence of the nasoseptal flap. PMID:23663897
Nguyen, Cu Dinh; Hult, Jenny; Sheikh, Rafi; Tenland, Kajsa; Dahlstrand, Ulf; Lindstedt, Sandra; Malmsjö, Malin
2017-10-11
It is well known that blood perfusion is important for the survival of skin flaps. As no study has been conducted to investigate how the blood perfusion in human eyelid skin flaps is affected by the flap length and diathermy, the present study was carried out to investigate these in patients. Fifteen upper eyelids were dissected as part of a blepharoplastic procedure, releasing a 30-mm long piece of skin, while allowing the 5 mm wide distal part of the skin to remain attached, to mimic a skin flap (hereafter called a "skin flap"). Blood perfusion was measured before and after repeated diathermy, using laser speckle contrast imaging. Blood perfusion decreased from the base to the tip of the flap: 5 mm from the base, the perfusion was 69%, at 10 mm it was 40%, at 15 mm it was 20%, and at 20 mm it was only 13% of baseline values. Diathermy further decreased blood perfusion (measured 15 mm from the base) to 13% after applying diathermy for the first time, to 6% after the second and to 4% after the third applications of diathermy. Blood perfusion falls rapidly with distance from the base of skin flaps on the human eyelid, and diathermy reduces blood perfusion even further. Clinically, it may be advised that flaps with a width of 5 mm be no longer than 15 mm (i.e., a width:length ratio of 1:3), and that the use of diathermy should be carefully considered.
Archer, Jacob B; Sun, Hai; Bonney, Phillip A; Zhao, Yan Daniel; Hiebert, Jared C; Sanclement, Jose A; Little, Andrew S; Sughrue, Michael E; Theodore, Nicholas; James, Jeffrey; Safavi-Abbasi, Sam
2016-03-01
This article introduces a classification scheme for extensive traumatic anterior skull base fracture to help stratify surgical treatment options. The authors describe their multilayer repair technique for cerebrospinal fluid (CSF) leak resulting from extensive anterior skull base fracture using a combination of laterally pediculated temporalis fascial-pericranial, nasoseptal-pericranial, and anterior pericranial flaps. Retrospective chart review identified patients treated surgically between January 2004 and May 2014 for anterior skull base fractures with CSF fistulas. All patients were treated with bifrontal craniotomy and received pedicled tissue flaps. Cases were classified according to the extent of fracture: Class I (frontal bone/sinus involvement only); Class II (extent of involvement to ethmoid cribriform plate); and Class III (extent of involvement to sphenoid bone/sinus). Surgical repair techniques were tailored to the types of fractures. Patients were assessed for CSF leak at follow-up. The Fisher exact test was applied to investigate whether the repair techniques were associated with persistent postoperative CSF leak. Forty-three patients were identified in this series. Thirty-seven (86%) were male. The patients' mean age was 33 years (range 11-79 years). The mean overall length of follow-up was 14 months (range 5-45 months). Six fractures were classified as Class I, 8 as Class II, and 29 as Class III. The anterior pericranial flap alone was used in 33 patients (77%). Multiple flaps were used in 10 patients (3 salvage) (28%)--1 with Class II and 9 with Class III fractures. Five (17%) of the 30 patients with Class II or III fractures who received only a single anterior pericranial flap had persistent CSF leak (p < 0.31). No CSF leak was found in patients who received multiple flaps. Although postoperative CSF leak occurred only in high-grade fractures with single anterior flap repair, this finding was not significant. Extensive anterior skull base fractures often require aggressive treatment to provide the greatest long-term functional and cosmetic benefits. Several vascularized tissue flaps can be used, either alone or in combination. Vascularized flaps are an ideal substrate for cranial base repair. Dual and triple flap techniques that combine the use of various anterior, lateral, and nasoseptal flaps allow for a comprehensive arsenal in multilayered skull base repair and salvage therapy for extensive and severe fractures.
NASA Astrophysics Data System (ADS)
Viswamurthy, S. R.; Ganguli, Ranjan
2007-03-01
This study aims to determine optimal locations of dual trailing-edge flaps to achieve minimum hub vibration levels in a helicopter, while incurring low penalty in terms of required trailing-edge flap control power. An aeroelastic analysis based on finite elements in space and time is used in conjunction with an optimal control algorithm to determine the flap time history for vibration minimization. The reduced hub vibration levels and required flap control power (due to flap motion) are the two objectives considered in this study and the flap locations along the blade are the design variables. It is found that second order polynomial response surfaces based on the central composite design of the theory of design of experiments describe both objectives adequately. Numerical studies for a four-bladed hingeless rotor show that both objectives are more sensitive to outboard flap location compared to the inboard flap location by an order of magnitude. Optimization results show a disjoint Pareto surface between the two objectives. Two interesting design points are obtained. The first design gives 77 percent vibration reduction from baseline conditions (no flap motion) with a 7 percent increase in flap power compared to the initial design. The second design yields 70 percent reduction in hub vibration with a 27 percent reduction in flap power from the initial design.
Asʼadi, Kamran; Salehi, Seyed Hamid; Shoar, Saeed
2017-01-01
Distally based fasciocutaneous sural flap is popular in the reconstruction of distal leg and foot burns. However, utilization of this technique in high-voltage electrical injury has been challenging. The present study aimed to compare the outcome of early aggressive debridement and coverage of contact point of acute high-voltage electrical injury using distally based fasciocutaneous sural flap between high-risk and low-risk patients defined by the anatomic proximity of the flap pedicle to the zone of injury. A total of 51 patients with contact point of high-voltage electrical burn (HVEB) in distal leg and foot undergoing distally based fasciocutaneous sural flap were included in this prospective clinical study. In 28 patients, the flap pedicle was not involved in the contact point of high-voltage electrical injury (low risk/control group), whereas in 21 patients, it was located inside the zone of injury (high-risk/case group). Patients were followed up for a median of 21 months (range, 12-44 months). Wound dimensions to be covered were relatively similar between the 2 groups. Complications of flap survival (primary outcome) and other minor early and late complications (secondary outcome) did not significantly differ between the 2 groups (P > 0.05). Provided that early and completed debridements of contact points of HVEB were achieved, distally based sural flap is feasible and there is reliable coverage in HVEB even in patients with flap pedicle located in vicinity of the zone of injury.
Surgeon-Based 3D Printing for Microvascular Bone Flaps.
Taylor, Erin M; Iorio, Matthew L
2017-07-01
Background Three-dimensional (3D) printing has developed as a revolutionary technology with the capacity to design accurate physical models in preoperative planning. We present our experience in surgeon-based design of 3D models, using home 3D software and printing technology for use as an adjunct in vascularized bone transfer. Methods Home 3D printing techniques were used in the design and execution of vascularized bone flap transfers to the upper extremity. Open source imaging software was used to convert preoperative computed tomography scans and create 3D models. These were printed in the surgeon's office as 3D models for the planned reconstruction. Vascularized bone flaps were designed intraoperatively based on the 3D printed models. Results Three-dimensional models were created for intraoperative use in vascularized bone flaps, including (1) medial femoral trochlea (MFT) flap for scaphoid avascular necrosis and nonunion, (2) MFT flap for lunate avascular necrosis and nonunion, (3) medial femoral condyle (MFC) flap for wrist arthrodesis, and (4) free fibula osteocutaneous flap for distal radius septic nonunion. Templates based on the 3D models allowed for the precise and rapid contouring of well-vascularized bone flaps in situ, prior to ligating the donor pedicle. Conclusions Surgeon-based 3D printing is a feasible, innovative technology that allows for the precise and rapid contouring of models that can be created in various configurations for pre- and intraoperative planning. The technology is easy to use, convenient, and highly economical as compared with traditional send-out manufacturing. Surgeon-based 3D printing is a useful adjunct in vascularized bone transfer. Level of Evidence Level IV. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Single-stage interpolation flaps in facial reconstruction.
Hollmig, S Tyler; Leach, Brian C; Cook, Joel
2014-09-01
Relatively deep and complex surgical defects, particularly when adjacent to or involving free margins, present significant reconstructive challenges. When the use of local flaps is precluded by native anatomic restrictions, interpolation flaps may be modified to address these difficult wounds in a single operative session. To provide a framework to approach difficult soft tissue defects arising near or involving free margins and to demonstrate appropriate design and execution of single-stage interpolation flaps for reconstruction of these wounds. Examination of our utilization of these flaps based on an anatomic region and surgical approach. A region-based demonstration of flap conceptualization, design, and execution is provided. Tunneled, transposed, and deepithelialized variations of single-stage interpolation flaps provide versatile options for reconstruction of a variety of defects encroaching on or involving free margins. The inherently robust vascularity of these flaps supports importation of necessary tissue bulk while allowing aggressive contouring to restore an intricate native topography. Critical flap design allows access to distant tissue reservoirs and placement of favorable incision lines while preserving the inherent advantages of a single operative procedure.
Quantitative analysis of skin flap blood flow in the rat using laser Doppler velocimetry.
Marks, N J
1985-01-01
Two experiments carried out on rat skin flaps are described, where microvascular flow has been measured noninvasively by a laser Doppler velocimeter. Using this technique it is possible to define the limits of an axial pattern flap in terms of microvascular flow; this was found to increase when the flap is elevated. 'Random-pattern' perfusion is defined by a fall in flow. This recovers sequentially along the flap, and at a constant rate at all sites. A differential in microvascular perfusion is thus maintained along a random-pattern flap for at least the first postoperative week. In a second experiment it is shown that there appears to be a linear relationship between the reduction in skin blood flow in a random-pattern flap and the distance from the base at which the measurements are made. It is suggested that these data support the view that the blood flow in a skin flap recovers primarily from its base rather than via peripheral neovascularization, and that this is due to vascular collaterals opening within the flap rather than to a relaxation of sympathetic tone. PMID:3156992
Closure of oroantral communications using biodegradable polyurethane foam: a feasibility study.
Visscher, Susan H; van Minnen, Baucke; Bos, Rudolf R M
2010-02-01
The aim of this study was to assess the feasibility of biodegradable polyurethane (PU) foam for closure of oroantral communications (OACs). Ten consecutive patients with OACs (existing <24 hours) were treated with PU foam. Standardized evaluations were performed at 2 weeks and 8 weeks after closure of the OAC. In 5 patients, the OACs were closed successfully without complications. Three patients developed sinusitis, which was conservatively managed with antibiotics in 2 cases. In 1 case the sinus was reopened for irrigation, after which a buccal flap procedure was performed. In 2 patients the OAC recurred and was surgically closed with a buccal flap after thorough irrigation. In this feasibility study, closure was achieved in 7 of the 10 patients without further surgical intervention. Complications of the procedure using PU foam may be related to the fit of the foam in the socket and the size of the perforation. In general, closure of OACs with biodegradable polyurethane foam is feasible and has the potential to spare a large number of patients with OACs a surgical procedure. Furthermore, in case the treatment with PU foam fails to close the OAC, the attending physician can always fall back on the standard surgical procedure. Copyright 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Clinical applications of dynamic infrared thermography in plastic surgery: a systematic review
John, Hannah Eliza; Niumsawatt, Vachara; Whitaker, Iain S.
2016-01-01
Background Infrared thermography (IRT) has become an increasingly utilized adjunct to more expensive and/or invasive investigations in a range of surgical fields, no more so than in plastic surgery. The combination of functional assessment, flow characteristics and anatomical localization has led to increasing applications of this technology. This article aims to perform a systematic review of the clinical applications of IRT in plastic surgery. Methods A systematic literature search using the keywords ‘IRT’ and ‘dynamic infrared thermography (DIRT)’ has been accomplished. A total of 147 papers were extracted from various medical databases, of which 34 articles were subjected to a full read by two independent reviewers, to ensure the papers satisfied the inclusion and exclusion criteria. Studies focusing on the use of IRT in breast cancer diagnosis were excluded. Results A systematic review of 29 publications demonstrated the clinical applications of IRT in plastic surgery today. They include preoperative planning of perforators for free flaps, post operative monitoring of free flaps, use of IRT as an adjunct in burns depth analysis, in assessment of response to treatment in hemangioma and as a diagnostic test for cutaneous melanoma and carpal tunnel syndrome (CTS). Conclusions Modern infrared imaging technology with improved standardization protocols is now a credible, useful non-invasive tool in clinical practice. PMID:27047781
Study of Flapping Flight Using Discrete Vortex Method Based Simulations
NASA Astrophysics Data System (ADS)
Devranjan, S.; Jalikop, Shreyas V.; Sreenivas, K. R.
2013-12-01
In recent times, research in the area of flapping flight has attracted renewed interest with an endeavor to use this mechanism in Micro Air vehicles (MAVs). For a sustained and high-endurance flight, having larger payload carrying capacity we need to identify a simple and efficient flapping-kinematics. In this paper, we have used flow visualizations and Discrete Vortex Method (DVM) based simulations for the study of flapping flight. Our results highlight that simple flapping kinematics with down-stroke period (tD) shorter than the upstroke period (tU) would produce a sustained lift. We have identified optimal asymmetry ratio (Ar = tD/tU), for which flapping-wings will produce maximum lift and find that introducing optimal wing flexibility will further enhances the lift.
Baillie, Daniel R; Stawicki, S Peter; Eustance, Nicole; Warsaw, David; Desai, Darius
2007-05-01
The goal of abdominal wall reconstruction is to restore and maintain abdominal domain. A PubMed(R) review of the literature (including "old" MEDLINE through February 2007) suggests that bioprosthetic materials are increasingly used to facilitate complex abdominal wall reconstruction. Reported results (eight case reports/series involving 137 patients) are encouraging. The most commonly reported complications are wound seroma (18 patients, 13%), skin dehiscence with graft exposure without herniation (six, 4.4%), superficial and deep wound infections (five, 3.6%), hernia recurrence (four, 2.9%), graft failure with dehiscence (two), hematoma (two), enterocutaneous fistula (one), and flap necrosis (one). Two recent cases are reported herein. In one, a 46-year-old woman required open abdominal management after gastric remnant perforation following a Roux-en-Y gastric bypass procedure. Porcine dermal collagen combined with cutaneous flaps was used for definitive abdominal wall reconstruction. The patient's condition improved postoperatively and she was well 5 months after discharge from the hospital. In the second, a 54-year-old woman underwent repair of an abdominal wall defect following resection of a large leiomyosarcoma. Human acellular dermis combined with myocutaneous flaps was used to reconstruct the abdominal wall defect. The patient's recovery was uncomplicated and 20 weeks following surgery she was doing well with no evidence of recurrence or hernia. The results reported to date and the outcomes presented here suggest that bioprosthetic materials are safe and effective for repair of large abdominal wall defects. Prospective, randomized, controlled studies are needed to compare the safety and efficacy of other reconstructive techniques as well as human and porcine dermal-derived bioprostheses.
Leclère, Franck M P; Schoofs, Michel; Buys, Bruno; Mordon, Serge R
2010-04-01
Microvascular surgery has become an important method for reconstructing surgical defects resulting from trauma, tumors, or burns. The most important factor for successful free flap transfer is a well-executed anastomosis. This study was performed to review the authors' experience with a 1.9-microm diode laser in microsurgery, with special attention to outcomes and performance of the technique. Between January of 2005 and December of 2007, 27 patients underwent microsurgery with a 1.9-microm diode laser at the authors' institute. The patients had a mean age of 31 years (range, 2 to 59 years); 14 patients were women and 13 patients were men. This technique was used for digital replantations (n = 2) and for free flap transfer (n = 27). Causes of the defects were trauma (n = 14), tumor (n = 9), congenital (n = 2), burn (n = 1), infection (n = 1), arthritis (n = 1), and dog bite (n = 1). Laser-assisted microvascular anastomosis was performed with a 1.9-microm diode laser after placement of equidistant stitches. The following parameters were used: spot size, 400 microm; power, 125 mW; time depending on vessel size (0.8 to 1.8 mm); and fluence varying from 70 to 200 J/cm. Three surgical revisions following hematoma and one rupture of the arterial anastomosis leading to a free deep inferior epigastric perforator flap necrosis resulting from high-dose radiotherapy before surgery occurred after laser-assisted microvascular anastomosis, accounting for an overall success rate of 96.6 percent. This study reports the numerous benefits of the technique: easier performance of vascular anastomosis with difficult access, decrease of reperfusion bleeding and complications, and a short learning curve.
Advances and Innovations in Microsurgery.
Park, Julie E; Chang, David W
2016-11-01
After reading this article, the participant should be able to: 1. summarize the evolution of perforator, chimeric, and free style flaps; 2. define and give examples of supermicrosurgery as well as understand its application in treatment of lymphedema; and 3. appreciate the development and advancements of composite tissue allotransplantation. Although microsurgery may seem like a highly specialized niche within plastic surgery, it is more than just a discipline that focuses on small anastomoses. It is a tool and a way of thinking that allows us to embody the true tenets of plastic surgery, as quoted by Tagliocozzi. What began as a challenge of returning amputated tissue to the body and achieving wound closure has evolved into a refinement of technique and change in philosophy that empowers the plastic surgeon to work creatively to "restore, rebuild, and make whole."
Efficacy of Liposuction as a Delay Method for Improving Flap Survival.
Orhan, Erkan; Erol, Yağmur Reyyan; Deren, Orgun; Altun, Serdar; Erdoğan, Bülent
2016-12-01
Flaps are often used in repairing tissue defects and partial or full flap loss is still an important morbidity cause. Several techniques have been tried to increase flap circulation but none of these could replace the delay technique. Our goal in this study is to show the efficacy of liposuction in delay of dorsal rat cutaneous flaps and improvement in flap survival. Twenty-four Wistar rats were used. The rats in group 1 received 9 × 3-sized caudally-based random pattern skin flaps. In group 2, liposuction was done under the tissue island spotted as the flap and after 14 days, standard flap surgery was done. In group 3, surgical delay was done and after 14 days, standard flap surgery was done. In group 4, liposuction was done under the tissue island spotted as the flap and standard flap surgery was done right after the liposuction. The rate of necrotic tissue in group 3 (surgical delay; mean % 13.7) was less than the rate in group 2 (liposuction delay; mean % 15.1), although the difference was not statistically significant. The necrosis rates in group 3 (surgical delay) and group 2 (liposuction delay) were less than the rates in both group 1 (only flap; mean % 41.5) and group 4 (liposuction flap; mean % 40.0) and this difference was statistically significant (p < 0.0001). Liposuction can be an alternative to surgical delay as a less invasive method in the clinic. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
An experimental study of pressures on 60 deg Delta wings with leading edge vortex flaps
NASA Technical Reports Server (NTRS)
Marchman, J. F., III; Terry, J. E.; Donatelli, D. A.
1983-01-01
An experimental study was conducted in the Virginia Tech Stability Wind Tunnel to determine surface pressures over a 60 deg sweep delta wing with three vortex flap designs. Extensive pressure data was collected to provide a base data set for comparison with computational design codes and to allow a better understanding of the flow over vortex flaps. The results indicated that vortex flaps can be designed which will contain the leading edge vortex with no spillage onto the wing upper surface. However, the tests also showed that flaps designed without accounting for flap thickness will not be optimum and the result can be oversized flaps, early flap vortex reattachment and a second separation and vortex at the wing/flap hinge line.
Beustes-Stefanelli, Matthieu; O'Toole, Greg; Schertenleib, Pierre
2016-01-01
In reconstructing anterior defects of the ear, postauricular flaps represent a popular option. The pedicle of such transauricular flaps can be superior, inferior, medial, or lateral. The postauricular helix-based adipodermal-pedicle turnover (PHAT) flap is an original single-stage transauricular technique for defects of the antihelix and scapha. Its skin paddle is on the posterior aspect of the ear. Its lateral de-epithelialized pedicle in front of the helix allows for it to easily reach peripheral anterior defects. In cases in which the underlying cartilage is involved, the extended PHAT (ePHAT) flap allows for restoring the contours of the ear without a cartilage graft. Between 2009 and 2011, a PHAT flap was used in 5 cases of defects of the antihelix or the scapha after tumor resection, 3 of which are in an extended version (ePHAT flap). There were no complications and a satisfactory aesthetic result was achieved in all cases. The PHAT flap is an original single-stage procedure for anterior auricular defects located on the antihelix or scapha. The single-layer PHAT flap is indicated in purely skin defect. The triple-layer ePHAT flap includes two subcutaneous extensions which increase its thickness and is indicated to restore the ear contours when cartilage has been removed.
Levator alae nasi muscle V-Y island flap for nasal tip reconstruction.
La Padula, Simone; Abbate, Vincenzo; Di Monta, Gianluca; Schonauer, Fabrizio
2017-03-01
Nasal tip reconstruction can be very challenging. It requires close attention to skin texture, colour and thickness matching, with the respect of the nasal aesthetic units and symmetry. Flaps are usually preferred to skin grafts where possible. Based on different donor areas, various flaps have been described for reconstruction of this region. Here we present a new V-Y myocutaneous island flap based on the levator alae nasi muscle (LAN muscle) blood supply. This flap may represent an alternative to the nasalis myocutaneous sliding V-Y flap previously described by Rybka. As its pivot point it is located more cranially than the nasalis flap, and it can advance more medially than the Rybka flap, with the possibility of covering larger defects of the nasal tip area, up to 1.8 cm in diameter. Over the past 5 years, 24 patients received nasal tip reconstruction with this flap following the resection of basal cell carcinomas. Good tip projection was maintained, and the aesthetic outcome was satisfactory, with well healed scars. We recommend this technique as an alternative to other flaps for nasal tip defects, especially if paramedian. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Fat necrosis in autologous abdomen-based breast reconstruction: a systematic review.
Khansa, Ibrahim; Momoh, Adeyiza O; Patel, Priti P; Nguyen, John T; Miller, Michael J; Lee, Bernard T
2013-03-01
Fat necrosis is a common and potentially exasperating complication of autologous breast reconstruction. The authors performed a systematic review of the English literature on autologous breast reconstruction to determine significant patient and surgical factors that are predictors of postoperative fat necrosis. A PubMed search using the terms "fat necrosis" and "breast reconstruction" was conducted. Articles were screened using predetermined inclusion and exclusion criteria. Data collected included patient characteristics, reconstructive techniques used, and the specific postoperative morbidity of interest. Patient cohorts were pooled, and the incidence of fat necrosis was calculated in the presence and absence of each risk factor. Chi-square analysis was applied, and p < 0.05 was considered statistically significant. Of 172 articles found, 70 met the inclusion criteria. The mean rate of fat necrosis was 11.3 percent. Deep inferior epigastric artery perforator flaps had the highest rate of fat necrosis (14.4 percent), followed by pedicled transverse rectus abdominis musculocutaneous (12.3 percent), superficial inferior epigastric artery (8.1 percent), and free transverse rectus abdominis musculocutaneous flaps (6.9 percent). Significant predictors of fat necrosis included obesity (p = 0.035), prereconstruction irradiation (p = 0.022), postreconstruction irradiation (p < 0.001), active smoking (p < 0.001), and abdominal scars (p = 0.05). Protective factors included supercharging (p < 0.001) and bilateral reconstruction (p = 0.01). Although there is little agreement in the literature regarding risk factors for fat necrosis, the authors were able to demonstrate several significant predictors by systematically analyzing 70 articles. Improved knowledge of the risk factors for fat necrosis can help surgeons provide improved preoperative counseling and take measures to minimize the risk of this complication.
New model of flap-gliding flight.
Sachs, Gottfried
2015-07-21
A new modelling approach is presented for describing flap-gliding flight in birds and the associated mechanical energy cost of travelling. The new approach is based on the difference in the drag characteristics between flapping and non-flapping due to the drag increase caused by flapping. Thus, the possibility of a gliding flight phase, as it exists in flap-gliding flight, yields a performance advantage resulting from the decrease in the drag when compared with continuous flapping flight. Introducing an appropriate non-dimensionalization for the mathematical relations describing flap-gliding flight, results and findings of generally valid nature are derived. It is shown that there is an energy saving of flap-gliding flight in the entire speed range compared to continuous flapping flight. The energy saving reaches the highest level in the lower speed region. The travelling speed of flap-gliding flight is composed of the weighted average of the differing speeds in the flapping and gliding phases. Furthermore, the maximum range performance achievable with flap-gliding flight and the associated optimal travelling speed are determined. Copyright © 2015 Elsevier Ltd. All rights reserved.
Degner, D A; Walshaw, R; Arnoczky, S P; Smith, R J; Patterson, J S; Degner, L A; Hamaide, A; Rosenstein, D
1996-01-01
This study evaluates the cranial rectus abdominus muscle pedicle flap as the sole blood supply for the caudal superficial epigastric skin flap. This flap was composed of a cranially based rectus abdominus muscle pedicle flap that was attached to the caudal superficial epigastric island skin flap (including mammary glands 2 to 5) via the pudendoepigastric trunk. Selective angiography of the cranial epigastric artery in eight cadaver dogs proved that the arterial vasculature in the cranial rectus abdominus was contiguous with that in the caudal superficial epigastric skin flap. In the live dog study, three of six of the flaps failed because of venous insufficiency. Necrosis of mammary gland 2 occurred in two of six flaps. One of six flaps survived with the exception of the cranial most aspect of mammary gland 2. Angiography of the cranial epigastric artery proved that arterial blood supply to these flaps was intact. Histological evaluation of the failed flaps showed full-thickness necrosis of the skin and subcutaneous tissues, the presence of severe congestion, and venous thrombosis. Retrograde venous blood flow through the flap was inconsistent, and hence resulted in failure of this myocutaneous flap. Use of this flap for clinical wound reconstruction cannot be recommended.
Holland, Roberto; Bisco Ferreira, Luciana; de Souza, Valdir; Otoboni Filho, José Arlindo; Murata, Sueli Satomi; Dezan, Eloi
2007-10-01
It has been shown that the mineral trioxide aggregate (MTA) used to seal lateral/furcal perforations stimulates the deposition of newly formed cementum. Nevertheless, when the site of the perforation is contaminated, the healing process might occur under less favorable conditions. This study evaluated the repair healing process of noncontaminated and contaminated lateral perforations filled with MTA and the effect of previously filling the contaminated perforations with a bactericidal agent. Thirty lateral root perforations were prepared in endodontically treated dog's teeth, thus forming 3 groups with 10 specimens each. In group 1 the perforations were immediately sealed with MTA. In group 2 the perforations were left open for 7 days and thereafter sealed with MTA. In group 3 the perforations were left open for 7 days, filled temporarily with a calcium hydroxide-based paste for 14 days, and then sealed with MTA. The animals were killed after 90 days, and the pieces were prepared for histomorphologic and histomicrobiologic evaluations. The statistical analysis showed that group 1 had significantly better repair than groups 2 (P < .05) and 3 (P < .05), which validates the superior results obtained when MTA was immediately used to seal root perforations. Groups 2 and 3 had statistically similar repair to each other (P > .05). There were a larger number of cases of complete or partial biologic seal in group 1 compared with the contaminated groups. It might be concluded that the lateral root perforations sealed with MTA after contamination presented worse repair than the noncontaminated, immediately sealed perforations. The temporary filling with a bactericidal agent (calcium hydroxide-based paste) did not improve the repair of perforations exposed to contamination, and the contaminated groups presented similar results to each other.
Moro, Alessandro; Saponaro, Gianmarco; Doneddu, Piero; Cervelli, Daniele; Pelo, Sandro; Gasparini, Giulio; Garagiola, Umberto; D'Amato, Giuseppe; Todaro, Mattia
2018-05-15
In 1992, Pribaz described the facial artery musculomucosal flap (FAMM), an axial musculomucosal flap based on the facial artery. The FAMM flap, a modification of the nasolabial and buccal mucosal flaps, is widely used in the reconstruction of defects in the oral cavity. Many modifications of this flap have been described in the literature. Here we aimed to explore the use of an arterialized tunnelized FAMM island flap (a-FAMMIF) for the reconstruction tongue defects after tumor resection. From January 2015 to December 2016, five cases of tongue cancer were selected for the use of arterialized FAMMIF flap to reconstruct defects after tumor resection. Reconstruction was successful in all cases, except one case of total flap necrosis; partial necrosis of the flap occurred in two patients, which were solved with medications. The authors consider the a-FAMMIF an unreliable flap in the reconstruction of tongue defects.The authors recommend avoiding tunneling and island modification when the vein is not included in the pedicle.
Kanuri, Arjun; Liu, Allen S; Guo, Lifei
2014-04-01
Skin flap necrosis is the most common complication following prosthesis-based breast reconstruction. Many studies have reported on the efficacy of laser-assisted indocyanine green angiography (SPY Elite System) in detecting flap necrosis. A cost-effectiveness analysis of laser-assisted indocyanine green angiography is lacking. The authors performed a retrospective review of all consecutive immediate postmastectomy prosthesis-based reconstructions at the Brigham and Women's Hospital over a 7-year 10-month period. The rate of mastectomy skin flap necrosis and related implant loss was determined for the entire cohort and for the subgroups of patients at increased risk for developing this complication: smokers, obese patients, and patients with large breasts. Cost of treating implant loss and skin flap necrosis was calculated based on the average treatment courses and costs at the authors' institution. The cost of the SPY was obtained from LifeCell Corp. From January of 2004 through October of 2011, 79 of 710 prosthesis-based breast reconstructions (11.1 percent) developed mastectomy skin flap necrosis requiring excision and reclosure. Performing laser-assisted indocyanine green angiography on the entire cohort would result in an additional cost of $1537.30 per case of flap necrosis prevented. If laser-assisted indocyanine green angiography was performed on only these high-risk subgroups, the cost savings per case of flap necrosis prevented is $2098.80 for smokers, $5162.30 for patients with a body mass index greater than 30, and $1892.70 for patients with mastectomy weight greater than 800 g. Laser-assisted indocyanine green angiography is not cost-effective as a preventative measure for flap necrosis if used indiscriminately on all patients undergoing prosthesis-based breast reconstructions, but it is cost-effective for high-risk patients, such as smokers, obese patients, and patients with large breasts.
Bolstering the Nasoseptal Flap Using Sphenoid Sinus Fat Packing: A Technical Case Report.
Abou-Al-Shaar, Hussam; Zaidi, Hasan A; Cote, David J; Laws, Edward R
2017-03-01
Resection of extensive skull base lesions often necessitates relatively large dural openings and arachnoid, resulting in skull base defects with the potential for a postoperative cerebrospinal fluid leak. A nasoseptal flap (NSF) is a vascularized graft that has greatly diminished the incidence of cerebrospinal fluid leak. Annealing of flaps against the ventral skull base can be tenuous within the first few days after surgery. We report the use of sphenoid sinus fat packing as a buttress to support the nasoseptal flap during skull base reconstruction. A 37-year-old man presented with pan-hypopituitarism, bitemporal hemianopsia, and imaging consistent with a craniopharyngioma. He underwent an endoscopic endonasal approach with resection of the planum and tuberculum sphenoidale for resection of this mass. An NSF was harvested, and a combination of suprasellar fat packing, tensor fasciae lata graft, and Porex plate along with the flap were used to reconstruct the skull base. Postoperatively, he precipitously experienced copious rhinorrhea necessitating surgical re-exploration. A redundant segment of the NSF had retracted into the sphenoid sinus, and was no longer supported against the ventral skull base. We repositioned the NSF and used sphenoid sinus fat packing to help support the graft against the ventral skull base. A postoperative computed tomographic scan demonstrated a clear delineation between the vascularized graft and the fat packing, confirming proper positioning of the flap. Sphenoid sinus fat packing can be an important technical adjunct in bolstering the nasoseptal flap against the ventral skull base in the tenuous early perioperative period. Copyright © 2016 Elsevier Inc. All rights reserved.
Reconstruction of palatal defect using mucoperiosteal hinge flap and pushback palatoplasty.
Lee, S I; Lee, H S; Hwang, K
2001-11-01
This article describes a simple, new surgical technique to provide a complete two-layer closure of palatal defect resulting from a surgical complication of trans palatal resection of skull base chordoma. The nasal layer was reconstructed with triangular shape oral mucoperiosteal turn over hinge flap based on anterior margin of palatal defect and rectangular shaped lateral nasal mucosal hinge flaps. The oral layer was reconstructed with conventional pushback V-Y advancement 2-flaps palatoplasty. Each layer of the flaps were secured with two key mattress suture for flap coaptation. This technique has some advantages: simple, short operation time, one-stage procedure, no need of osteotomy. It can close small- to medium-sized palatal defect of palate or wide cleft palate and can prevent common complication of oronasal fistula, which could be caused by tension.
Geometric analysis of the V-Y advancement flap and its clinical applications.
Andrades, Patricio R; Calderon, Wilfredo; Leniz, Patricio; Bartel, German; Danilla, Stefan; Benitez, Susana
2005-05-01
Geometry is fundamental in the comprehension of local flap design. The purpose of this study was to discuss the differences between the V-Y advancement flap and other local flaps, understand its geometry, and analyze its clinical applications. The analysis was based on qualitative measurements of an injury, taking into consideration the following dimensions: largest diameter, shortest diameter, and depth. Standardization of the flap design consisted of directing its advancement over the shortest diameter and making the V base match the size of the largest diameter. The flap was analyzed in two planes: the horizontal plane includes the V-Y design and the vertical plane includes the flap pedicle. The height of the flap can be obtained by simple trigonometry, taking into consideration the largest diameter and alpha angle in the horizontal plane. In the vertical plane, where the pedicle and pivot plane are positioned, for known shortest diameter and depth, the final depth of the pivot plane can be calculated using Pythagoras' principles. This analysis was applied to 25 patients with adequate skin coverage at follow-up. A correction factor was added to reduce the overdeepening of the vertical plane calculations. The final concepts for clinical application in the classic deep pedicle V-Y flap design are to calculate the length of the V by modifying the alpha angle and to move the pivot plane deeper to accomplish optimal flap movement. Using these principles, tension-free closure of the Y and appropriate advancement of the flap are obtained.
Merali, N; Hussain, A
2015-01-01
An iatrogenic caecal perforation is rare, but a serious complication associated with significant morbidity and mortality. We present a 4min and 50s video on a new improvisation undertaken during laparoscopic management of post-polypectomy caecal perforation. Our patient presented with an acute abdomen following endoscopic polypectomy. At surgery, the site of caecal perforation was close to the appendicular base with devitalization tissue, secondary to diathermy usage. The hallmark of safety within this novel technique included fresh healthy tissue margins within the endoloop (detachable snare ligation) and ensuring no ischemic tissue was gathered. Complete freeing of the appendix and meso-appendicular base was required and securing three endoloops proximal to the site of perforation. The post-operative course was uneventful. The World Society of Emergency Surgery (WSES) 2013 guidelines suggested an early laparoscopic approach is a safe and effective treatment for colonoscopy-related colonic perforation. There are no national guidelines and the management is dictated by the clinical condition of the patient, co-morbidity, size and site of perforation as well as the scale of bowel preparation, and surgical experience. The endoloop technique described, undertaken during a laparoscopy is a novel approach. It is a simple and effective method, reminding clinicians to adapt techniques when necessary. Nevertheless, it is only limited to perforations around the appendicular base. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Merali, N.; Hussain, A.
2015-01-01
Introduction An iatrogenic caecal perforation is rare, but a serious complication associated with significant morbidity and mortality. We present a 4 min and 50 s video on a new improvisation undertaken during laparoscopic management of post-polypectomy caecal perforation. Presentation of case Our patient presented with an acute abdomen following endoscopic polypectomy. At surgery, the site of caecal perforation was close to the appendicular base with devitalization tissue, secondary to diathermy usage. The hallmark of safety within this novel technique included fresh healthy tissue margins within the endoloop (detachable snare ligation) and ensuring no ischemic tissue was gathered. Complete freeing of the appendix and meso-appendicular base was required and securing three endoloops proximal to the site of perforation. The post-operative course was uneventful. Discussion The World Society of Emergency Surgery (WSES) 2013 guidelines suggested an early laparoscopic approach is a safe and effective treatment for colonoscopy-related colonic perforation. There are no national guidelines and the management is dictated by the clinical condition of the patient, co-morbidity, size and site of perforation as well as the scale of bowel preparation, and surgical experience. Conclusion The endoloop technique described, undertaken during a laparoscopy is a novel approach. It is a simple and effective method, reminding clinicians to adapt techniques when necessary. Nevertheless, it is only limited to perforations around the appendicular base. PMID:25723744
Probe Without Moving Parts Measures Flow Angle
NASA Technical Reports Server (NTRS)
Corda, Stephen; Vachon, M. Jake
2003-01-01
The measurement of local flow angle is critical in many fluid-dynamic applications, including the aerodynamic flight testing of new aircraft and flight systems. Flight researchers at NASA Dryden Flight Research Center have recently developed, flight-tested, and patented the force-based flow-angle probe (FLAP), a novel, force-based instrument for the measurement of local flow direction. Containing no moving parts, the FLAP may provide greater simplicity, improved accuracy, and increased measurement access, relative to conventional moving vane-type flow-angle probes. Forces in the FLAP can be measured by various techniques, including those that involve conventional strain gauges (based on electrical resistance) and those that involve more advanced strain gauges (based on optical fibers). A correlation is used to convert force-measurement data to the local flow angle. The use of fiber optics will enable the construction of a miniature FLAP, leading to the possibility of flow measurement in very small or confined regions. This may also enable the tufting of a surface with miniature FLAPs, capable of quantitative flow-angle measurements, similar to attaching yarn tufts for qualitative measurements. The prototype FLAP was a small, aerodynamically shaped, low-aspect-ratio fin about 2 in. (approximately equal to 5 cm) long, 1 in. (approximately equal to 2.5 cm) wide, and 0.125 in. (approximately equal to 0.3 cm) thick (see Figure 1). The prototype FLAP included simple electrical-resistance strain gauges for measuring forces. Four strain gauges were mounted on the FLAP; two on the upper surface and two on the lower surface. The gauges were connected to form a full Wheatstone bridge, configured as a bending bridge. In preparation for a flight test, the prototype FLAP was mounted on the airdata boom of a flight-test fixture (FTF) on the NASA Dryden F-15B flight research airplane.
Wind-tunnel free-flight investigation of a 0.15-scale model of the F-106B airplane with vortex flaps
NASA Technical Reports Server (NTRS)
Yip, Long P.
1987-01-01
An investigation to determine the effects of vortex flaps on the flight dynamic characteristics of the F-106B in the area of low-speed, high-angle-of-attack flight was undertaken on a 0.15-scale model of the airplane in the Langley 30- by 60-Foot Tunnel. Static force tests, dynamic forced-oscillation tests, as well as free-flight tests were conducted to obtain a data base on the flight characteristics of the F-106B airplane with vortex flaps. Vortex flap configurations tested included a full-span gothic flap, a full-span constant-chord flap, and a part-span gothic flap.
Research on the Perforating Algorithm Based on STL Files
NASA Astrophysics Data System (ADS)
Yuchuan, Han; Xianfeng, Zhu; Yunrui, Bai; Zhiwen, Wu
2018-04-01
In the process of making medical personalized external fixation brace, the 3D data file should be perforated to increase the air permeability and reduce the weight. In this paper, a perforating algorithm for 3D STL file is proposed, which can perforate holes, hollow characters and engrave decorative patterns on STL files. The perforating process is composed of three steps. Firstly, make the imaginary space surface intersect with the STL model, and reconstruct triangles at the intersection. Secondly, delete the triangular facets inside the space surface and make a hole on the STL model. Thirdly, triangulate the inner surface of the hole, and thus realize the perforating. Choose the simple space equations such as cylindrical and rectangular prism equations as perforating equations can perforate round holes and rectangular holes. Through the combination of different holes, lettering, perforating decorative patterns and other perforated results can be accomplished. At last, an external fixation brace and an individual pen container were perforated holes using the algorithm, and the expected results were reached, which proved the algorithm is feasible.
Pressure investigation of NASA leading edge vortex flaps on a 60 deg Delta wing
NASA Technical Reports Server (NTRS)
Marchman, J. F., III; Donatelli, D. A.; Terry, J. E.
1983-01-01
Pressure distributions on a 60 deg Delta Wing with NASA designed leading edge vortex flaps (LEVF) were found in order to provide more pressure data for LEVF and to help verify NASA computer codes used in designing these flaps. These flaps were intended to be optimized designs based on these computer codes. However, the pressure distributions show that the flaps wre not optimum for the size and deflection specified. A second drag-producing vortex forming over the wing indicated that the flap was too large for the specified deflection. Also, it became apparent that flap thickness has a possible effect on the reattachment location of the vortex. Research is continuing to determine proper flap size and deflection relationships that provide well-behaved flowfields and acceptable hinge-moment characteristics.
Abdominal- versus thigh-based reconstruction of perineal defects in patients with cancer.
Pang, John; Broyles, Justin M; Berli, Jens; Buretta, Kate; Shridharani, Sachin M; Rochlin, Danielle H; Efron, Jonathan E; Sacks, Justin M
2014-06-01
An abdominoperineal resection is an invasive procedure that leaves the patient with vast pelvic dead space. Traditionally, the vertical rectus abdominus myocutaneous flap is used to reconstruct these defects. Oftentimes, this flap cannot be used because of multiple ostomy placements or previous abdominal surgery. The anterolateral thigh flap can be used; however, the efficacy of this flap has been questioned. We report a single surgeon's experience with perineal reconstruction in patients with cancer with the use of either the vertical rectus abdominus myocutaneous flap or the anterolateral thigh flap to demonstrate acceptable outcomes with either repair modality. From 2010 to 2012, 19 consecutive patients with perineal defects secondary to cancer underwent flap reconstruction. A retrospective chart review of prospectively entered data was conducted to determine the frequency of short-term and long-term complications. This study was conducted at an academic, tertiary-care cancer center. Patients in the study were patients with cancer who were receiving perineal reconstruction. Interventions were surgical and included either abdomen- or thigh-based reconstruction. The main outcome measures included infection, flap failure, length of stay, and time to radiotherapy. Of the 19 patients included in our study, 10 underwent anterolateral thigh flaps and 9 underwent vertical rectus abdominus myocutaneous flaps for reconstruction. There were no significant differences in demographics between groups (p > 0.05). Surgical outcomes and complications demonstrated no significant differences in the rate of infection, hematoma, bleeding, or necrosis. The mean length of stay after reconstruction was 9.7 ± 3.4 days (± SD) in the anterolateral thigh flap group and 13.4 ± 7.7 days in the vertical rectus abdominus myocutaneous flap group (p > 0.05). The limitations of this study include a relatively small sample size and retrospective evaluation. This study suggests that the anterolateral thigh flap is an acceptable alternative to the vertical rectus abdominus myocutaneous flap for perineal reconstruction (see Video, Supplemental Digital Content 1, http://links.lww.com/DCR/A134).
Valerio, Ian; Green, J Marshall; Sacks, Justin M; Thomas, Shane; Sabino, Jennifer; Acarturk, T Oguz
2015-01-01
Large segmental bone and composite tissue defects often require vascularized osseous flaps for definitive reconstruction. However, failed osseous flaps due to inadequate perfusion can lead to significant morbidity. Utilization of indocyanine green (ICG) fluorescence angiography has been previously shown to reliably assess soft tissue perfusion. Our group will outline the application of this useful intraoperative tool in evaluating the perfusion of vascularized osseous flaps. A retrospective review was performed to identify those osseous and/or osteocutaneous bone flaps, where ICG angiography was employed. Data analyzed included flap types, success and failure rates, and perfusion-related complications. All osseous flaps were evaluated by ICG angiography to confirm periosteal and endosteal perfusion. Overall 16 osseous free flaps utilizing intraoperative ICG angiography to assess vascularized osseous constructs were performed over a 3-year period. The flaps consisted of the following: nine osteocutaneous fibulas, two osseous-only fibulas, two scapular/parascapular with scapula bone, two quadricep-based muscle flaps, containing a vascularized femoral bone component, and one osteocutaneous fibula revision. All flap reconstructions were successful with the only perfusion-related complication being a case of delayed partial skin flap loss. Intraoperative fluorescence angiography is a useful adjunctive tool that can aid in flap design through angiosome mapping and can also assess flap perfusion, vascular pedicle flow, tissue perfusion before flap harvest, and flap perfusion after flap inset. Our group has successfully extended the application of this intraoperative tool to assess vascularized osseous flaps in an effort to reduce adverse outcomes related to preventable perfusion-related complications. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Li, Nailu; Mu, Anle; Yang, Xiyun; Magar, Kaman T; Liu, Chao
2018-05-01
The optimal tuning of adaptive flap controller can improve adaptive flap control performance on uncertain operating environments, but the optimization process is usually time-consuming and it is difficult to design proper optimal tuning strategy for the flap control system (FCS). To solve this problem, a novel adaptive flap controller is designed based on a high-efficient differential evolution (DE) identification technique and composite adaptive internal model control (CAIMC) strategy. The optimal tuning can be easily obtained by DE identified inverse of the FCS via CAIMC structure. To achieve fast tuning, a high-efficient modified adaptive DE algorithm is proposed with new mutant operator and varying range adaptive mechanism for the FCS identification. A tradeoff between optimized adaptive flap control and low computation cost is successfully achieved by proposed controller. Simulation results show the robustness of proposed method and its superiority to conventional adaptive IMC (AIMC) flap controller and the CAIMC flap controllers using other DE algorithms on various uncertain operating conditions. The high computation efficiency of proposed controller is also verified based on the computation time on those operating cases. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.
[Analysis of sequelae of the latissimus dorsi flap removal. Report of 44 cases reviewed and tested].
Legré, R; Boghossian, V; Servant, J M; Magalon, G; Bureau, H
1990-01-01
Since Tanzini, the latissimus dorsi muscle flap has been widely used in plastic surgery. Based on the experience of two plastic surgery units, we decided to try to define the sequelae of this operation. In order to simplify our analysis we only considered free flaps. Out study is based on 42 patients (26 pure muscular flaps and 16 musculo-cutaneous flaps). The sequelae were analysed in terms of aesthetic and functional criteria. The aesthetic sequelae appeared to be minima in the case of pure muscular flaps, but more severe in the case of musculo-cutaneous flaps. Functional sequelae in the shoulder were observed on muscle testing in 30% of cases, although there were no repercussions on sport or work activities. Analysis of spinal posture demonstrated a modification in the frontal plane in 40% of cases although this could not be clearly attributed to the donor site. On the basis of this study, we can conclude that the latissimus dorsi flap retains an important place in the therapeutic arsenal of plastic surgery due to its reliability and its minor cicatricial and functional sequelae at the donor site.
One stage reconstruction of the floor of the mouth with a subcutaneous pedicled nasolabial flap.
El-Marakby, Hamdy H; Fouad, Fouad A; Ali, Ahmed H
2012-06-01
Nasolabial flaps have been recognised as versatile flaps for a variety of defects in the face, nose, lip and the oral cavity. Random pattern inferiorly based nasolabial flaps (NLF) have been utilised for covering small defects on the anterior floor of the mouth, but usually require a second stage procedure to divide the flap base. A subcutaneous pedicled inferiorly based nasolabial flap can provide a one stage repair of moderate sized defects of the floor of the mouth after de epithelialisation of the base of the flap. To evaluate the feasibility of a single stage reconstruction of intermediate sized defects in the oral cavity with an inferiorly based pedicled NLF. The study includes the indications of use of the flap, flap design, technique, and the complications rate. The incidence of secondary procedures and the final functional and the aesthetic results will also be evaluated. A group of 20 patients presented with (T1-2) squamous cell carcinoma of the oral cavity have been treated at the Department of Surgery, National Cancer Institute, Cairo; in the period between January 2008 and September 2010. The pathology was confirmed with an incision biopsy and all metastatic work were carried out confirming that all patients were free from distant metastasis at presentation. Preoperative assessment also included assessment of the stage of the disease, the flap design and patient fitness for general anaesthesia. All patients underwent surgical excision combined with reconstruction of the defect with a subcutaneous inferiorly based pedicled NLF. The proximal part of the flap was routinely de epithelialised before it has been tunnelled through the cheek so a one stage procedure could only be required. The mean age of the patients was 62.3±6years, range (52-69years). All patients were diagnosed with squamous cell carcinoma. The anterior floor of the mouth constituted 40% of the defects, the lateral floor of the mouth 20% and the inner surface of the cheek 40%. There was no reported major complication; and only one patient suffered a reactionary haemorrhage that required re-exploration to secure the bleeder. A single procedure was adequate in most patients (80%), only 20% of patients required revision of the scar at the donor site or release of the tongue. The overall aesthetic results were either very satisfactory or satisfactory in the majority of patients (90%). Two patients were not satisfied with the final aesthetic results, one suffered from ectropion and the other had a donor site wound healing problem. The functional results (deglutition, speech) were satisfactory in most patients (70%), all were edentulous. An inferiorly based pedicled NLF is a reliable flap for the reconstruction of small and medium sized defects in the oral cavity. The flap can be best utilised for old edentulous and high risk patients where it can be used as a single stage procedure which is particularly useful in those types of patients. The flap can be safely combined with neck dissection even when the facial artery was ligated. Copyright © 2012 National Cancer Institute, Cairo University. Published by Elsevier B.V. All rights reserved.
The Economy in Autologous Tissue Transfer: Part 1. The Kiss Flap Technique.
Zhang, Yi Xin; Hayakawa, Thomas J; Levin, L Scott; Hallock, Geoffrey G; Lazzeri, Davide
2016-03-01
All reconstructive microsurgeons realize the need to improve aesthetic and functional donor-site outcomes. A "kiss" flap design concept was developed to increase the surface area of skin flap coverage while minimizing donor-site morbidity. The main goal of the kiss flap technique is to harvest multiple skin paddles that are smaller than those raised with traditional techniques, to minimize donor-site morbidity. These smaller flap components are then sutured to each other, or said to kiss each other side-by-side, to create a large, wide flap. The skin paddles in the kiss technique can be linked to one another by a variety of native intrinsic vascular connections, by additional microanastomosis, or both. This technique can be widely applied to both free and pedicle flaps, and essentially allows for the reconstruction of a large defect while providing the easy primary closure of a smaller donor-site defect. According to their origin of blood supply, kiss flaps are classified into three styles and five types. All of the different types of kiss flaps are unique in both flap design and harvest technique. Most kiss flaps are based on common flaps already familiar to the reconstructive surgeon. The basis of the kiss flap design concept is to convert multiple narrow flaps into a single unified flap of the desired greater width. This maximizes the size of the resulting flap and minimizes donor-site morbidity, as a direct linear closure is usually possible. Therapeutic, V.
Hu, Melissa; Ludlow, David; Alexander, J Steven; McLarty, Jerry; Lian, Timothy
2014-03-01
To determine if the intravascular delivery of mesenchymal stem cells improves wound healing and blood perfusion to postischemic cutaneous flap tissues. Randomized controlled study. A murine model of a cutaneous flap was created based on the inferior epigastric vessels. Mice (n = 14) underwent 3.5 hours of ischemia followed by reperfusion. Bone marrow stromal cells (BMSCs) 1 × 10(6) were injected intravenously. Wound healing was then assessed measuring percent flap necrosis, flap perfusion, and tensile strength of the flap after a period of 14 days. Localization of BMSCs was determined with radiolabeled and fluorescent labeled BMSCs. Postischemic cutaneous flap tissues treated with BMSCs demonstrated significantly less necrosis than control flaps (P <0.01). Beginning on postoperative day 5, BMSC-treated flaps demonstrated greater blood perfusion than untreated flaps (P <0.01). Tensile strength of BMSC-treated cutaneous flaps was significantly higher (P <0.01), with a mean strength of 283.4 ± 28.4 N/m than control flaps with a mean of 122.4 ± 23.5 N/m. Radiolabeled BMSCs localized to postischemic flaps compared to untreated tissues (P = 0.001). Fluorescent microscopy revealed incorporation of BMSCs into endothelial and epithelial tissues of postischemic flaps. This study demonstrates that the intravascular delivery of BMSCs increases wound healing and promotes flap survival following ischemia-reperfusion injury of cutaneous tissue flaps. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.
Retention of a reconstructed nipple using a C-V flap with different layer thicknesses in the C-flap.
Sowa, Yoshihiro; Itsukage, Sizu; Sakaguchi, Kouichi; Taguchi, Tetsuya; Numajiri, Toshiaki
2018-04-01
The C-V flap for nipple reconstruction is now one of standard surgical techniques. But decreased projection is still a problem. In recent years, it has been suggested that projection can be more easily maintained when raising of the C-flap is performed with a split thickness dermis. In this study, we examined whether decrease of projection can be prevented by raising of a C-flap with a split dermis rather than with full dermis. A total of 49 consecutive patients who underwent reconstruction of a nipple using the C-V flap technique were enrolled. The patients included 22 who underwent surgery using a C-flap with a full thickness dermis (Group F), and 27 who underwent surgery with raising of a flap with a split thickness dermis (Group S). The size of the reconstructed nipple was measured at 2 weeks, 6 months and 1 year postoperatively for comparison between Groups F and S. Partial necrosis of the C-flap end occurred in 4 subjects in only Group S. The decrease in projection after 1 year postoperatively in Group S was significantly lower than that in Group F. In contrast, the teat base size in Group F tended to be greater than that in Group S, suggesting a tendency for an expanded base using a flap with a full dermis. Our results indicated that it is recommended to use a C-flap with a split dermis for cases with high projection of the nipple on the contralateral side.
[Clinical experience with the supraclavicular flap to reconstruct head and neck defects].
Zhang, Bin; Yan, Dangui; Zhang, Yabing; Zhang, Xiwei; Wan, Hanfeng
2015-06-01
To evaluate the efficacy of pedicled supraclavicular artery island flaps for head and neck reconstruction. Reconstructive surgeries for head and neck oncologic defects were performed with the pedicled supraclavicular artery island flaps in 10 patients from May 2013 to December 2014 and the cases were review. Among them, 6 were performed for hypopharyngeal cancer, 2 for oral tongue cancer, 1 for oral base cancer and 1 for cervical esophageal cancer. The size of the flaps was measured in (5-8) cm × (6-12) cm. Seven flaps survived, one flap failured and two flaps had partial necrosis. Donor sites were closed primarily without morbidity. The pedicled supraclavicular artery island flap is an easy harvesting and reliable for head and neck reconstruction, especially suitable for otolaryngo-head and neck surgeon and maxillofacial surgeon in the local hospital.
NASA Technical Reports Server (NTRS)
Warner, R. W.; Wilcox, P. R.
1972-01-01
Free-oscillation damping measurements at hypersonic and transonic Mach numbers are presented for the lower pitch flap of the M2-F2 reentry vehicle. For the flow and model conditions tested, the damping measurements indicate the absence of hypersonic buzz instability for flap rotation frequencies of 47.3 Hz, 153 Hz, and 360 Hz, the presence of transonic buzz for 47.3 Hz flap, and the absence of transonic buzz for a 115 Hz flap. There are not enough flap damping data for an error estimate based on repeatability, but a partial damping calibration is presented in which an analog computer simulation of random flap response for a known flap damping is fed into the autocorrelation computer and filter combination used for most of the damping measurements.
Temporalis myofascial flap for primary cranial base reconstruction after tumor resection.
Eldaly, Ahmed; Magdy, Emad A; Nour, Yasser A; Gaafar, Alaa H
2008-07-01
To evaluate the use of the temporalis myofascial flap in primary cranial base reconstruction following surgical tumor ablation and to explain technical issues, potential complications, and donor site consequences along with their management. Retrospective case series. Tertiary referral center. Forty-one consecutive patients receiving primary temporalis myofascial flap reconstructions following cranial base tumor resections in a 4-year period. Flap survival, postoperative complications, and donor site morbidity. Patients included 37 males and 4 females ranging in age from 10 to 65 years. Two patients received preoperative and 18 postoperative radiation therapy. Patient follow-up ranged from 4 to 39 months. The whole temporalis muscle was used in 26 patients (63.4%) and only part of a coronally split muscle was used in 15 patients (36.6%). Nine patients had primary donor site reconstruction using a Medpor((R)) (Porex Surgical, Inc., Newnan, GA) temporal fossa implant; these had excellent aesthetic results. There were no cases of complete flap loss. Partial flap dehiscence was seen in six patients (14.6%); only two required surgical débridement. None of the patients developed cerebrospinal leaks or meningitis. One patient was left with complete paralysis of the temporal branch of the facial nerve. Three patients (all had received postoperative irradiation) developed permanent trismus. The temporalis myofascial flap was found to be an excellent reconstructive alternative for a wide variety of skull base defects following tumor ablation. It is a very reliable, versatile flap that is usually available in the operative field with relatively low donor site aesthetic and functional morbidity.
Lower extremity soft tissue reconstruction with free flap based on subscapular artery.
Karşıdağ, Semra; Akçal, Arzu; Turgut, Gürsel; Uğurlu, Kemal; Baş, Lütfü
2011-01-01
The purpose of our study was to evaluate the results of the reconstruction of the lower extremity defects with free flaps based on the subscapular artery. Between January, 1998 and December, 2008, 51 patients (mean age 26 years; 16 female and 35 male) presenting with a lower extremity defect underwent a reconstructive surgery with flaps based on the subscapular vascular system. Thirty-seven percent of the defects were located in the crus, 19% in the sole, 16% in the heel, and 14% in the dorsum of the foot. Eighty and a half percent of the patients had traffic-accident-related and 13.5% had burn-related tissue defects. Fifty-three percent of the patients presenting with lower extremity defects underwent reconstruction with latissimus dorsi muscle flaps, 21% with free serratus muscle and/or fascia flaps, 14% with free parascapular fasciocutaneous flaps, and 12% with free combined latissimus muscle and serratus muscle and/or fascia flaps. Anastomoses of 80% of the patients were performed on their posterior tibial artery and accompanying veins and/or foot dorsal veins. End-to-end anastomosis was performed on 14 patients, while 35 patients received end-to-side anastomosis. Six patients were treated with cross free flaps, of which 4 received cross latissimus, 1 cross serratus, and 1 cross combined serratus and latissimus flaps. End-to-side anastomoses were performed on these patients on the cross-leg tibialis posterior artery. The cross-leg anastomosis was freed 4 weeks later. In the early period, venous occlusion was observed in 4 patients and arterial and venous occlusion was present in 1 patient. New anastomoses were performed in these patients. Partial necrosis was observed in 2 patients. The average follow-up period was 61 months. Pressure-related late ulcerative lesions developed in 4 patients. The lesions of these patients were repaired by debridement and primary suturing or partial thickness skin grafts. The subscapular vascular system based flaps have an optimal vascularity once they are prepared with adequate pedicles, causing minimal donor site morbidity. These flaps are a safe and effective alternative in lower extremity reconstruction. On the other hand, in the absence of appropriate recipient vessels, single or combined cross-leg free flaps may provide successful repair.
"Palmar pivot flap" for resurfacing palmar lateral defects of the fingers.
Yam, Andrew; Peng, Yeong-Pin; Pho, Robert Wan-Heng
2008-12-01
Soft tissue defects on the lateral borders of the digits are difficult to reconstruct using local or local-regional flaps. We describe a "palmar pivot flap" to resurface an adjacent defect on the palmar-lateral aspect of the digit. The surgical technique is described. This flap is an axial pattern flap based on the subcutaneous transverse branches of the digital artery. The flap is pivoted up to 90 degrees on the neurovascular bundle in its base, into an adjacent defect. The flap can be raised from either the proximal or the middle phalangeal segments. It can cover defects sited from the level of the proximal interphalangeal joint up to the fingertip. The donor defect is limited to the same digit and is covered with a full-thickness skin graft. We have used this flap on 3 patients with defects at the middle phalangeal segment, the distal interphalangeal joint, and the fingertip. All healed primarily. One patient had a mild flexion contracture of the proximal interphalangeal joint, whereas the other 2 had no complications. The patients with distal interphalangeal joint and fingertip defects had excellent sensation in the flap (2-point discrimination of 5-6 mm). The palmar pivot flap is useful for resurfacing otherwise difficult defects on the lateral borders of the digits around and distal to the proximal interphalangeal joint, including those at the fingertip. It provides sensate, glabrous skin. The donor defect is on the same digit and is well hidden, producing an aesthetic and functional reconstruction.
"Internet of Things" Real-Time Free Flap Monitoring.
Kim, Sang Hun; Shin, Ho Seong; Lee, Sang Hwan
2018-01-01
Free flaps are a common treatment option for head and neck reconstruction in plastic reconstructive surgery, and monitoring of the free flap is the most important factor for flap survival. In this study, the authors performed real-time free flap monitoring based on an implanted Doppler system and "internet of things" (IoT)/wireless Wi-Fi, which is a convenient, accurate, and efficient approach for surgeons to monitor a free flap. Implanted Doppler signals were checked continuously until the patient was discharged by the surgeon and residents using their own cellular phone or personal computer. If the surgeon decided that a revision procedure or exploration was required, the authors checked the consumed time (positive signal-to-operating room time) from the first notification when the flap's status was questioned to the determination for revision surgery according to a chart review. To compare the efficacy of real-time monitoring, the authors paired the same number of free flaps performed by the same surgeon and monitored the flaps using conventional methods such as a physical examination. The total survival rate was greater in the real-time monitoring group (94.7% versus 89.5%). The average time for the real-time monitoring group was shorter than that for the conventional group (65 minutes versus 86 minutes). Based on this study, real-time free flap monitoring using IoT technology is a method that surgeon and reconstruction team can monitor simultaneously at any time in any situation.
Superfast 3D shape measurement of a flapping flight process with motion based segmentation
NASA Astrophysics Data System (ADS)
Li, Beiwen
2018-02-01
Flapping flight has drawn interests from different fields including biology, aerodynamics and robotics. For such research, the digital fringe projection technology using defocused binary image projection has superfast (e.g. several kHz) measurement capabilities with digital-micromirror-device, yet its measurement quality is still subject to the motion of flapping flight. This research proposes a novel computational framework for dynamic 3D shape measurement of a flapping flight process. The fast and slow motion parts are separately reconstructed with Fourier transform and phase shifting. Experiments demonstrate its success by measuring a flapping wing robot (image acquisition rate: 5000 Hz; flapping speed: 25 cycles/second).
Free flap reconstruction for diabetic foot limb salvage.
Sato, Tomoya; Yana, Yuichiro; Ichioka, Shigeru
2017-12-01
Although free flap is gaining popularity for the reconstruction of diabetic foot ulcers, it is unclear whether free flap reconstruction increases the chances of postoperative independent ambulation. The aim of this study is to evaluate the relationship between free flap success and postoperative ambulation. This study reviewed 23 cases of free flap reconstruction for diabetic foot ulcers between January 2007 and March 2014. Free rectus abdominis, latissimus dorsi, and anterolateral thigh flaps were used in ten, eight, and five patients, respectively. A comparison was made between free flap success and postoperative independent ambulation using Fisher's exact test. Two patients developed congestive heart failure with fatal consequences within 14 days postoperatively, resulting in an in-hospital mortality rate of 8.7%. Five patients lost their flaps (21.7%). Of the 16 patients who had flap success, 12 achieved independent ambulation. Five patients with flap loss did not achieve independent ambulation, except one patient who underwent secondary flap reconstruction using a distally based sural flap. Fisher's exact test revealed that independent ambulation was associated with free flap success (p = 0.047). The present study indicates that free flap reconstruction may increase the possibility of independent ambulation for patients with extensive tissue defects due to diabetic ulcers. Intermediate limb salvage rates and independent ambulation rates were favourable in patients with successful reconstruction. The use of foot orthoses and a team approach with pedorthists were effective to prevent recurrence.
Djedovic, Gabriel; Morandi, Evi M; Metzler, Julia; Wirthmann, Anna; Matiasek, Johannes; Bauer, Thomas; Rieger, Ulrich M
2017-12-01
The development of pressure sores is still not only an enormous economical but also a medical burden. Especially in the ischial region, the local defect coverage remains demanding as it is the main weight-bearing area in wheelchair-mobilised patients and is prone to high mobility. The purpose of our study was to report our long-time experience with the reconstruction of ischial pressure ulcers with the medially based posterior thigh flap. A retrospective analysis of all primary pressure sores grade III-IV in the ischial area, which were covered with a medially based posterior thigh flap between January 2008 and December 2014, at our department was conducted. A total of 28 patients underwent defect coverage of an ischial pressure sore with the aforementioned flap. The subgroup with complications showed a statistically significant longer hospital stay. A statistically significant correlation between age and the coincidence of comorbidities could be seen. Older patients showed significantly higher grades of pressure sores. The medially based posterior thigh flap is a safe and reliable flap design. Complication rates are comparable to other flaps. Nevertheless, in case of complications, a significantly longer duration of hospitalisation has to be taken into account. © 2017 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
The number of operations required for completing breast reconstruction.
Eom, Jin Sup; Kobayashi, Mark Robert; Paydar, Keyianoosh; Wirth, Garrett A; Evans, Gregory R D
2014-10-01
Breast reconstruction often requires multiple surgeries, which demands additional expense and time and is often contrary to the patient's expectation. The aim of this study was to review the number of operations that were needed for completion of breast reconstruction and to determine patient and clinical factors that influenced this number. We retrospectively reviewed the medical records of 254 cases of breast reconstructions (in 185 patients) that were performed between February 2005 and August 2009. We investigated the numbers of operations that were performed for individual case of breast reconstruction and analyzed the influence of variable factors. The purpose of the additional operations was also analyzed. The mean number of operations per breast was 2.37 (range, 1-9). The mean number of operations for mound creation was 2.24. Factors associated with an increased number of operation were use of an implant, contralateral symmetrization, complications, and nipple reconstruction. Considering the reconstruction method, either the use of a primary implant or the use of free abdominal tissue transfer demonstrated fewer surgeries than the use of an expander implant, and the number of operations using free transverse rectus abdominis musculocutaneous or deep inferior epigastric perforator flaps was less than the number of operations using pedicled transverse rectus abdominis musculocutaneous flaps. These data will aid in planning breast reconstruction surgery and will enable patients to be more informed regarding the likelihood of multiple surgeries.
Erçöçen, A R; Yilmaz, S; Saydam, M
2003-01-01
Unoperated bilateral complete cleft lip and palate in an adult or elderly patient is seen rarely, and the existence of unoperated clefts is a result of unfavorable economic and social circumstances. We report an unoperated 65-year-old patient with bilateral complete cleft lip and palate and present our preference for the surgical management. Repair of the bilateral complete cleft lip and palate was successfully carried out using straight-line closure for the bilateral cleft lip and two-flap pushback palatoplasty with superiorly based lateral port control pharyngeal flap for the wide cleft palate at the first stage, and large residual anterior palatal fistulas were closed using bilateral superiorly based (retrograde flow) full-thickness nasolabial island flaps at the second stage. To our knowledge based on a review of the literature, this is the first report of an elderly patient with bilateral complete cleft lip and palate and the first application of bilateral superiorly based (retrograde flow) full-thickness nasolabial island flaps for closure of large residual anterior palatal fistulas or alveolar clefts. The bilateral superiorly based (retrograde flow) full-thickness nasolabial island flap may be a good solution in large anterior palatal defects using unilaterally or bilaterally in a single stage with minimal donor site morbidity, in which there is not enough tissue for local repair or if previous attempts are unsuccessful.
Reconstruction of Facial Defect Using Deltopectoral Flap.
Aldelaimi, Tahrir N; Khalil, Afrah A
2015-11-01
Reconstruction of the head and neck is a challenge for otolarygology surgeons, maxillofacial surgeons as well as plastic surgeons. Defects caused by the resection and/or trauma should be closed with flaps which match in color, texture and hair bearing characteristics with the face. Deltopectoral flap is a one such flap from chest and neck skin mainly used to cover the facial defects. This study report a patient presenting with tragic Road Traffic Accident (RTA) admitted to maxillofacial surgery department at Ramadi Teaching Hospital, Anbar province, Iraq. An incision, medially based, was done and deltopectoral fascio-cutaneous flap was used for surgical exposure and closure of defects after RTA. There was no major complication. Good aesthetic and functional results were achieved. Deltopectoral flap is an excellent alternative for the reconstruction of head and neck. Harvesting and application of the flap is rapid and safe. Only a single incision is sufficient for dissection and flap elevation.
Gloor, Jason W; Balakrishnan, Lata; Campbell, Judith L; Bambara, Robert A
2012-08-01
In eukaryotic Okazaki fragment processing, the RNA primer is displaced into a single-stranded flap prior to removal. Evidence suggests that some flaps become long before they are cleaved, and that this cleavage involves the sequential action of two nucleases. Strand displacement characteristics of the polymerase show that a short gap precedes the flap during synthesis. Using biochemical techniques, binding and cleavage assays presented here indicate that when the flap is ∼ 30 nt long the nuclease Dna2 can bind with high affinity to the flap and downstream double strand and begin cleavage. When the polymerase idles or dissociates the Dna2 can reorient for additional contacts with the upstream primer region, allowing the nuclease to remain stably bound as the flap is further shortened. The DNA can then equilibrate to a double flap that can bind Dna2 and flap endonuclease (FEN1) simultaneously. When Dna2 shortens the flap even more, FEN1 can displace the Dna2 and cleave at the flap base to make a nick for ligation.
[A reverse vascular autograft finger island flap. A review of 15 cases and of the literature].
Adani, R; Marcuzzi, A; Busa, R; Pancaldi, G; Bathia, A; Caroli, A
1995-01-01
The authors discuss the indications for homodigital island flap with a reverse vascular pedicle. This flap is based on the anastomoses between the radial and ulnar digital arteries. These anastomotic branches lie between the posterior wall of the tendon sheath and the periosteum to form an arch and are named the "digitopalmar arches". The vascularization of the reverse homodigital island flap is derived by using the middle transverse palmar arch. This flap was performed successfully in 14 patients involving 15 fingers to resurface amputation of the distal phalanx. In 6 cases the flap was used as an "artery" flap, and in 9 cases as a "sensitive" homodigital island flap. The pedicle in these cases was neurovascular also containing the digital nerve. The sensitivity of the flap was obtained by neurorraphy between the transposed digital nerve of the flap and the receiving digital nerve of the recipient finger. This technique achieves cover of the tactile pad in one operative stage and provides well vascularized skin allowing early mobilization. Sensation of the flap can be restored rapidly when neurorraphy of the transposed digital nerve is performed.
Effect of Krueger nose flaps on the experimental force and moment characteristics of an oblique wing
NASA Technical Reports Server (NTRS)
Hopkins, E. J.; Lovette, G. H.
1976-01-01
Experimental force and moment data are presented for an oblique wing mounted on a body of revolution and equipped with Krueger type nose flaps. The effectiveness of these flaps in making the moment curves more linear by controlling the flow separation on the downstream wing panel at high lift coefficients was determined. The investigation of the effects of the Krueger flaps covered two cases: (1) use of the flaps on the downstream wing panel only and (2) use of the flaps on both wing panels. For part of the tests, the Krueger flaps were mounted on nose flaps that were drooped either 5 deg or 10 deg. The wing was elliptical in planform, had an aspect ratio of 6.0 (based on the unswept span) and was tested at sweep angles of 0, 45 deg, and 50 deg. The Mach-number range covered was from 0.25 to 0.95. It was found that the most effective arrangement of the Krueger flaps for making the pitching-, rolling-, and yawing-moment curves more linear at high lift coefficients was having the Krueger flaps mounted on the nose flaps drooped 5 deg and only on the downstream wing panel.
[Surgical issues and outcomes in ischial pressure sores treatment].
Voulliaume, D; Grecea, M; Viard, R; Brun, A; Comparin, J-P; Foyatier, J-L
2011-12-01
Ischiatic pressure sores are frequent in spinal cord injury patients, associated with bad prognosis and high recurrence rate. Many surgical techniques were described, including surgical debridement followed by pedicled flap coverage. We aim to propose a practical decision tree for primary or secondary ischial pressure sore treatment. Our series of 48 operated ischial sores with an average follow up of 4 years (range 2 to 8years) is analyzed and compared to previously published reports. Surgical techniques are discussed according to their specific indications. The optimal recurrence rate in published reports about pressure sore treatment is 20%; a rate inferior to 19% is found in our series, showing the equal importance of flap selection and postoperative care and education. Depending on each situation, various available flaps are described and compared: gluteus maximus flap, biceps femoris flap, gracilis flap, tensor fascia lata flap, fasciocutaneous thigh flaps, rectus femoris and vastus lateralis flap, rectus abdominis flap. Specific surgical indications for more extensive wounds are studied: resection arthroplasty of the hip, hip disarticulation, fillet flaps from the leg, microsurgery. Based upon our experience, a decision tree summarizes our proposition of flap selection, depending on the wound size and the patient background. Copyright © 2010 Elsevier Masson SAS. All rights reserved.
Li, Xiucun; Cui, Jianli; Maharjan, Suraj; Lu, Laijin; Gong, Xu
2016-01-01
Objective The purpose of this study is to determine the correlation between non-technical risk factors and the perioperative flap survival rate and to evaluate the choice of skin flap for the reconstruction of foot and ankle. Methods This was a clinical retrospective study. Nine variables were identified. The Kaplan-Meier method coupled with a log-rank test and a Cox regression model was used to predict the risk factors that influence the perioperative flap survival rate. The relationship between postoperative wound infection and risk factors was also analyzed using a logistic regression model. Results The overall flap survival rate was 85.42%. The necrosis rates of free flaps and pedicled flaps were 5.26% and 20.69%, respectively. According to the Cox regression model, flap type (hazard ratio [HR] = 2.592; 95% confidence interval [CI] (1.606, 4.184); P < 0.001) and postoperative wound infection (HR = 0.266; 95% CI (0.134, 0.529); P < 0.001) were found to be statistically significant risk factors associated with flap necrosis. Based on the logistic regression model, preoperative wound bed inflammation (odds ratio [OR] = 11.371,95% CI (3.117, 41.478), P < 0.001) was a statistically significant risk factor for postoperative wound infection. Conclusion Flap type and postoperative wound infection were both independent risk factors influencing the flap survival rate in the foot and ankle. However, postoperative wound infection was a risk factor for the pedicled flap but not for the free flap. Microvascular anastomosis is a major cause of free flap necrosis. To reconstruct complex or wide soft tissue defects of the foot or ankle, free flaps are safer and more reliable than pedicled flaps and should thus be the primary choice. PMID:27930679
Design of an antagonistic shape memory alloy actuator for flap type control surfaces
NASA Astrophysics Data System (ADS)
Dönmez, Burcu; Özkan, Bülent
2011-03-01
This paper deals with the flap control of unmanned aerial vehicles (UAVs) using shape memory alloy (SMA) actuators in an antagonistic configuration. The use of SMA actuators has the advantage of significant weight and cost reduction over the conventional actuation of the UAV flaps by electric motors or hydraulic actuators. In antagonistic configuration, two SMA actuators are used: one to rotate the flap clockwise and the other to rotate the flap counterclockwise. In this content, mathematical modeling of strain and power dissipation of SMA wire is obtained through characterization tests. Afterwards, the model of the antagonistic flap mechanism is derived. Later, based on these models both flap angle and power dissipation of the SMA wire are controlled in two different loops employing proportional-integral type and neural network based control schemes. The angle commands are converted to power commands through the outer loop controller later, which are updated using the error in the flap angle induced because of the indirect control and external effects. In this study, power consumption of the wire is introduced as a new internal feedback variable. Constructed simulation models are run and performance specifications of the proposed control systems are investigated. Consequently, it is shown that proposed controllers perform well in terms of achieving small tracking errors.
Hemi-transseptal Approach for Pituitary Surgery: A Follow-Up Study
Fnais, Naif; Maio, Salvatore Di; Edionwe, Susan; Zeitouni, Anthony; Sirhan, Denis; Valdes, Constanza J.; Tewfik, Marc A.
2016-01-01
Objectives The hemi-transseptal (Hemi-T) approach was developed to overcome the potential drawbacks of the nasoseptal flap (NSF) in endoscopic endonasal transsphenoidal skull base surgery. In this study, we describe further refinements on the Hemi-T approach, and report long-term outcomes as compared with traditional methods of skull base reconstruction. Design A retrospective case-control study. Setting Montreal Neurological Institute and Jewish General Hospital, Montreal, Canada. Participants Patients who underwent endoscopic endonasal transsphenoidal approach to skull base pathology. Main Outcome Measures Operative time, CSF rhinorrhea, and postoperative nasal morbidity. Results A total of 105 patients underwent the Hemi-T approach versus 40 controls. Operative time was shorter using the Hemi-T technique (180.51 ± 56.9 vs. 202.9 ± 62 minutes; p = 0.048). The rates of nasal morbidity (septal perforation [5/102 vs. 6/37; p = 0.029] and mucosal adhesion [11/102 vs. 10/39 p = 0.027]), fascia lata harvest (21/100 vs. 18/39; p = 0.0028), and postoperative CSF leak rates (7/100 vs. 9/38; p = 0.006) were lower in the Hemi-T group. Conclusion Advantages of the Hemi-T approach over traditional exposure techniques include preservation of the nasal vascular pedicle, shorter operative time, reduced fascia lata harvest rates, and decreased nasal morbidity. PMID:28321378
Nzarubara, Gabriel R
2005-03-01
Our understanding of the cause and treatment of peptic ulcer disease has changed dramatically over the last couple of decades. It was quite common some years ago to treat chronic ulcers surgically. These days, the operative treatment is restricted to the small proportion of ulcer patients who have complications such as perforation. The author reports seven cases of perforated duodenal ulcers seen in a surgical clinic between 1995 and 2001. Recommendations on the criteria for selecting the appropriate surgical intervention for patients with perforated duodenal ulcer are given. To decide on the appropriate surgical interventions for patients with perforated duodenal ulcer. These are case series of 7 patients who presented with perforated duodenal ulcers without a history of peptic ulcer disease. Seven patients presented with perforated duodenal ulcer 72 hours after perforation in a specialist surgical clinic in Kampala were analyzed. Appropriate management based on these patients is suggested. These patients were initially treated in upcountry clinics for acute gastritis from either alcohol consumption or suspected food poisoning. There was no duodenal ulcer history. As a result, they came to specialist surgical clinic more than 72 hours after perforation. Diagnosis of perforated duodenal ulcer was made and they were operated using the appropriate surgical intervention. Diagnosis of hangovers and acute gastritis from alcoholic consumption or suspected food poisoning should be treated with suspicion because the symptoms and signs may mimic perforated peptic ulcer in "silent" chronic ulcers. The final decision on the appropriate surgical intervention for patients with perforated duodenal ulcer stratifies them into two groups: The previously fit patients who have relatively mild physiological compromise imposed on previously healthy organ system by the perforation can withstand the operative stress of definitive procedure. The Second category includes patients who are critically ill, who poorly tolerate any operation and hence poor surgical risks. These require urgent, adequate resuscitation and simple suture with omental patch.
Measurement of the volume of the pedicled TRAM flap in immediate breast reconstruction.
Chang, K P; Lin, S D; Hou, M F; Lee, S S; Tsai, C C
2001-12-01
The transverse rectus abdominis musculocutaneous (TRAM) flap is now accepted as the standard for breast reconstruction, but achieving symmetrical breast reconstruction is still a challenge. A precise estimate of the volume of the flap is necessary to reconstruct a symmetrical and aesthetically pleasing breast. Many methods have been developed to overcome this problem, but they have not been suitable for the pedicled TRAM flap. By using a self-made device based on the Archimedes' principle, the authors can calculate accurately the volume of the pedicled TRAM flap and predict reliably the breast volume intraoperatively. The "procedure" is based on a self-made box into which the pedicled TRAM flap is placed. Warm saline is added to the box and the flap is then removed. Flap volume is calculated easily by determining the difference between the preestimated volume of the box and the volume of the residual water. From February to May 2000, this method was used on 28 patients to predict breast volume for breast reconstruction. This study revealed that the difference of the maximal chest circumferences (the index of the breast volume) demonstrates a positive correlation with the difference of the volumes and weights between the mastectomy specimen and the net TRAM flap. However, a more closely positive correlation exists between the differences of maximal chest circumference volume (r = 0.677) than maximal chest circumference weight (r = 0.618). These data reveal that the reconstructed breast's volume has a closer relationship with the volume of the net pedicled TRAM flap, rather than with its weight.
NASA Astrophysics Data System (ADS)
Kamaruzaman, N. F.; Abdullah, E. J.
2017-12-01
Shape memory alloy (SMA) actuator offers great solution for aerospace applications with low weight being its most attractive feature. A SMA actuation mechanism for the flapping micro unmanned aerial vehicle (MAV) is proposed in this study, where SMA material is the primary system that provides the flapping motion to the wings. Based on several established design criteria, a design prototype has been fabricated to validate the design. As a proof of concept, an experiment is performed using an electrical circuit to power the SMA actuator to evaluate the flapping angle. During testing, several problems have been observed and their solutions for future development are proposed. Based on the experiment, the average recorded flapping wing angle is 14.33° for upward deflection and 12.12° for downward deflection. This meets the required design criteria and objective set forth for this design. The results prove the feasibility of employing SMA actuators in flapping wing MAV.
NASA Astrophysics Data System (ADS)
Mallick, Rajnish; Ganguli, Ranjan; Seetharama Bhat, M.
2015-09-01
The objective of this study is to determine an optimal trailing edge flap configuration and flap location to achieve minimum hub vibration levels and flap actuation power simultaneously. An aeroelastic analysis of a soft in-plane four-bladed rotor is performed in conjunction with optimal control. A second-order polynomial response surface based on an orthogonal array (OA) with 3-level design describes both the objectives adequately. Two new orthogonal arrays called MGB2P-OA and MGB4P-OA are proposed to generate nonlinear response surfaces with all interaction terms for two and four parameters, respectively. A multi-objective bat algorithm (MOBA) approach is used to obtain the optimal design point for the mutually conflicting objectives. MOBA is a recently developed nature-inspired metaheuristic optimization algorithm that is based on the echolocation behaviour of bats. It is found that MOBA inspired Pareto optimal trailing edge flap design reduces vibration levels by 73% and flap actuation power by 27% in comparison with the baseline design.
Perforated Sigmoid Diverticular Disease: a Management Protocol
Moin, Thajammul
2008-01-01
Background: To develop an evidence-based protocol for the management of perforated sigmoid diverticular disease. Methods: A search of the literature was undertaken. All publications pertaining to perforated sigmoid diverticular disease were analyzed and then categorized according to their level of evidence. Recommendations were then made on the basis of this. Results: Multiple case reports suggest that primary closure of perforation of sigmoid diverticula is safe in the absence of peritoneal contamination. Conclusions: A 2-stage laparoscopic approach incorporating the principles of damage limitation surgery may be a safe strategy in the management of perforated diverticular disease. PMID:18435896
Golbin, Denis A.; Lasunin, Nikolay V.; Cherekaev, Vasily A.; Polev, Georgiy A.
2016-01-01
Objectives To evaluate the efficacy and safety of using a buccal fat pad for endoscopic skull base defect reconstruction. Design Descriptive anatomical study with an illustrative case presentation. Setting Anatomical study was performed on 12 fresh human cadaver specimens with injected arteries (24 sides). Internal carotid artery was exposed in the coronal plane via the endoscopic transpterygoid approach. The pedicled buccal fat pad was used for reconstruction. Participants: 12 human cadaver head specimens; one patient operated using the proposed technique. Main outcome measures: Proximity of the buccal fat pad flap to the defect, compliance of the flap, comfort and safety of harvesting procedure, and compatibility with the Hadad–Bassagasteguy nasoseptal flap. Results: Harvesting procedure was performed using anterior transmaxillary corridor. The pedicled buccal fat pad flap can be used to pack the sphenoid sinus or cover the internal carotid artery from cavernous to upper parapharyngeal segment. Conclusion The buccal fat pad can be safely harvested through the same approach without external incisions and is compliant enough to conform to the skull base defect. The proposed pedicled flap can replace free abdominal fat in central skull base reconstruction. The volume of the buccal fat pad allows obliteration of the sphenoid sinus or upper parapharyngeal space. PMID:28180047
Subcutaneous pedicle propeller flap: An old technique revisited and modified!
Karki, Durga; Mehta, Nikhil; Narayan, Ravi Prakash
2016-01-01
Background: Post-burn axillary and elbow scar contracture is a challenging problem to the reconstructive surgeon owing to the wide range of abduction and extension that should be achieved, respectively, while treating either of the joint. The aim of this paper is to highlight the use of subcutaneous pedicle propeller flap for the management of post-burn axillary and elbow contractures. Methodology: This is a prospective case study of axillary and elbow contractures managed at a tertiary care hospital using propeller flap based on subcutaneous pedicle from 2009 to 2014. Surgical treatment comprised of subcutaneous-based pedicle propeller flap from the normal tissue within the contracture based on central axis pedicle. The flap was rotated axially to break the contracture. The technique further encompassed a modification, a Zig-Zag incision of the flap, which was seen to prevent hypertrophy along the incision line. There was a mean period of 12 months of follow-up. Results: Thirty-eight patients consisting of 22 males and 16 females were included in this study among which 23 patients had Type II axillary contractures and 15 had moderate flexion contractures at elbow joint. The post-operative abduction achieved at shoulder joint had a mean of 168° whereas extension achieved at elbow had a mean of 175°. The functional and aesthetic results were satisfactory. Conclusion: The choice of surgical procedure for reconstruction of post-burn upper extremity contractures should be made according to the pattern of scar contracture and the state of surrounding skin. The choice of subcutaneous pedicle propeller flap should be emphasised because of the superior functional results of flap as well as ease to learn it. Moreover, the modification of propeller flap described achieves better results in terms of scar healing. There is an inter-positioning of healthy skin in between the graft, so it prevents scar band formation all around the flap. PMID:27833285
Subcutaneous pedicle propeller flap: An old technique revisited and modified!
Karki, Durga; Mehta, Nikhil; Narayan, Ravi Prakash
2016-01-01
Post-burn axillary and elbow scar contracture is a challenging problem to the reconstructive surgeon owing to the wide range of abduction and extension that should be achieved, respectively, while treating either of the joint. The aim of this paper is to highlight the use of subcutaneous pedicle propeller flap for the management of post-burn axillary and elbow contractures. This is a prospective case study of axillary and elbow contractures managed at a tertiary care hospital using propeller flap based on subcutaneous pedicle from 2009 to 2014. Surgical treatment comprised of subcutaneous-based pedicle propeller flap from the normal tissue within the contracture based on central axis pedicle. The flap was rotated axially to break the contracture. The technique further encompassed a modification, a Zig-Zag incision of the flap, which was seen to prevent hypertrophy along the incision line. There was a mean period of 12 months of follow-up. Thirty-eight patients consisting of 22 males and 16 females were included in this study among which 23 patients had Type II axillary contractures and 15 had moderate flexion contractures at elbow joint. The post-operative abduction achieved at shoulder joint had a mean of 168° whereas extension achieved at elbow had a mean of 175°. The functional and aesthetic results were satisfactory. The choice of surgical procedure for reconstruction of post-burn upper extremity contractures should be made according to the pattern of scar contracture and the state of surrounding skin. The choice of subcutaneous pedicle propeller flap should be emphasised because of the superior functional results of flap as well as ease to learn it. Moreover, the modification of propeller flap described achieves better results in terms of scar healing. There is an inter-positioning of healthy skin in between the graft, so it prevents scar band formation all around the flap.
Silvestre, Luís; Pedro, Luís Mendes; Fernandes e Fernandes, Ruy; Silva, Emanuel; Fernandes e Fernandes, José
2015-10-01
The rectus femoris (RF) muscle flap, which is widely used to cover groin infected vascular grafts, is usually harvested through distal tendon division and an extensive muscle elevation and transposition into the groin wound defect. A case of a vascular prosthetic graft infection in the groin was successfully controlled after coverage with an RF flap that was harvested based on proximal portion mobilization instead of the conventional distal one. This case suggests that the RF muscle flap based on proximal insertion mobilization is a feasible, effective, technically simpler, and less invasive alternative to cover infected vascular grafts in the groin. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Wagner, Till; Hupkens, Pieter; Slater, Nicholas J; Ulrich, Dietmar J O
2016-04-01
Coverage of soft-tissue defects of the knee due to multiple operations, trauma, and infection remains a surgical challenge. Often, these defects are repaired using free tissue transfer. The aim of this study was to find an easy and reliable local method of repair for small to medium-sized defects. The authors describe a new surgical option for tissue coverage using a proximally based long peroneal muscle turnover flap (LPTF) with split-thickness skin graft. Proximally based LPTFs were harvested and transposed into same-size created defects in five cadavers. After optimizing this technique, it was clinically used in two patients with defects secondary to total knee replacement revisions. Average cadaver flap size was 4.7 × 15.8 cm allowing reach of all knee joint areas and was based consistently on a sufficient (2-mm-diameter average) proximal arterial branch of the anterior tibial artery. Donor sites were closed without tension. Subsequent application of the flap on two patients resulted in good functional outcome. The proximally based LPTF is a new option available in the reconstruction of knee defects and should be added to the reconstructive surgeon's armamentarium of pedicled flaps, providing short operating time and promising clinical outcome. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Temml, Veronika; Garscha, Ulrike; Romp, Erik; Schubert, Gregor; Gerstmeier, Jana; Kutil, Zsofia; Matuszczak, Barbara; Waltenberger, Birgit; Stuppner, Hermann; Werz, Oliver; Schuster, Daniela
2017-02-01
Leukotrienes (LTs) are pro-inflammatory lipid mediators derived from arachidonic acid (AA) with roles in inflammatory and allergic diseases. The biosynthesis of LTs is initiated by transfer of AA via the 5-lipoxygenase-activating protein (FLAP) to 5-lipoxygenase (5-LO). FLAP inhibition abolishes LT formation exerting anti-inflammatory effects. The soluble epoxide hydrolase (sEH) converts AA-derived anti-inflammatory epoxyeicosatrienoic acids (EETs) to dihydroxyeicosatetraenoic acids (di-HETEs). Its inhibition consequently also counteracts inflammation. Targeting both LT biosynthesis and the conversion of EETs with a dual inhibitor of FLAP and sEH may represent a novel, powerful anti-inflammatory strategy. We present a pharmacophore-based virtual screening campaign that led to 20 hit compounds of which 4 targeted FLAP and 4 were sEH inhibitors. Among them, the first dual inhibitor for sEH and FLAP was identified, N-[4-(benzothiazol-2-ylmethoxy)-2-methylphenyl]-N’-(3,4-dichlorophenyl)urea with IC50 values of 200 nM in a cell-based FLAP test system and 20 nM for sEH activity in a cell-free assay.
Total Reconstruction of Lower Eyelid in a Post-traumatic Patient Using Modified Fricke's Cheek Flap.
Sengupta, Subhabrata; Baruah, Binayak; Pal, Suvra; Tuli, Isha Preet
2013-07-01
Eyelids are very complex structure, reconstruction of which is a challenge to surgeons. Reconstruction of eyelids may be required in a variety of conditions like congenital anomalies, trauma, or postsurgical excision in malignant lesions involving the eyelids. There are numerous ways to reconstruct the eyelids; the best procedure depends on both the skill of the surgeon and the condition of the patient. Fricke' lateral temporal based flap was first described in 1829 for reconstruction of the eyelids and lateral canthal region. This flap had inherent problems regarding cosmetic appearance of the eyebrows. The modified Fricke's flap based on the cheek has the advantage of avoiding such complications. It is very easy and rapid outpatient department (OPD) based procedure with acceptable cosmetic and functional result. It can be done by all ear, nose, and throat (ENT) and head and neck surgeons without any reconstructive training. In this article we are presenting a case of total reconstruction of lower eyelid using the modified Fricke's cheek flap.
Modified trans-oral approach with an inferiorly based flap.
Al-Holou, Wajd N; Park, Paul; Wang, Anthony C; Than, Khoi D; Marentette, Lawrence J
2010-04-01
The trans-oral approach allows direct access to pathologies of the anterior craniocervical junction. However, the classic midline incision of the posterior pharyngeal wall can be surgically burdensome and limits lateral exposure. We reviewed the medical records of nine patients undergoing the trans-oral approach. The sites of the pathology ranged from the clivus to C2, and surgical exposure ranged from the clivus to C3. Each operation utilized an inferiorly based flap. None of the patients experienced vascular or neurologic complications, and no patient had a cerebrospinal fluid fistula, pseudomeningocele, or meningitis postoperatively. The trans-oral approach with an inferiorly based flap can therefore be safely and effectively performed with minimal oropharyngeal and neurologic morbidity. Not only does a U-shaped flap allow adequate exposure from the lower half of the clivus to C3, a flap improves lateral exposure, provides a clear operating field, and allows superficial mucosal closure not directly overlying the operative field. (c) 2009 Elsevier Ltd. All rights reserved.
A novel animal model for skin flap prelamination with biomaterials
NASA Astrophysics Data System (ADS)
Zhou, Xianyu; Luo, Xusong; Liu, Fei; Gu, Chuan; Wang, Xi; Yang, Qun; Qian, Yunliang; Yang, Jun
2016-09-01
Several animal models of skin flap construction were reported using biomaterials in a way similar to prefabrication. However, there are few animal model using biomaterials similar to prelamination, another main way of clinical skin flap construction that has been proved to be reliable. Can biomaterials be added in skin flap prelamination to reduce the use of autogenous tissues? Beside individual clinical attempts, animal model is needed for randomized controlled trial to objectively evaluate the feasibility and further investigation. Combining human Acellular Dermal Matrix (hADM) and autologous skin graft, we prelaminated flaps based on inguinal fascia. One, two, three and four weeks later, hADM exhibited a sound revascularization and host cell infiltration. Prelaminated skin flaps were then raised and microsurgically transplanted back to groin region. Except for flaps after one week of prelamination, flaps from other subgroups successfully reconstructed defects. After six to sixteen weeks of transplantation, hADM was proved to being able to maintain its original structure, having a wealth of host tissue cells and achieving full revascularization.To our knowledge, this is the first animal model of prelaminating skin flap with biomaterials. Success of this animal model indicates that novel flap prelamination with biomaterials is feasible.
Gallbladder perforation complicating typhoid fever: report of two cases.
Gali, B M; Ali, N; Agbese, G O; Duna, V D; Dawha, S D; Ismai, G I; Mohammed, M
2011-01-01
Gallbladder perforation (GBP) is rare and as a complication of typhoid fever is extremely rare. We present two consecutive patients with GBP diagnosed incidentally at laparotomy. Information on the management of two patients with gallbladder perforation seen at Federal Medical Centre Azare in June and October 2008 was extracted from their case records. The two patients were both males aged 13 years and 16 years. They both presented with high fever of more than 2 weeks duration; and abdominal pain and distension. Both patients had features of generalised peritonitis. Pre-operative diagnoses of typhoid enteric perforation were made based on a positive Widal test. Intra-operative findings however, were that of bile peritonitis and gallbladder perforation. Both had cholecystectomy. Culture of the bile aspirate yielded Salmonella typhi. Gallbladder perforation secondary to typhoid fever should be considered as a differential diagnosis in patients with suspected typhoid enteric perforation in typhoid fever endemic region.
Transition to nonpenetrating trabecular surgery: sclerotrabeculectomy.
Sourdille, Philippe; Santiago, Pierre Yves; Bresson-Dumont, Hélène
2002-12-01
A transition from trabeculectomy to nonpenetrating trabecular surgery (NPTS) is proposed under the name of sclerotrabeculectomy. The technique, which is aimed at facilitating the transition to NPTS, is a modification of both penetrating and nonpenetrating techniques. Sclerotrabeculectomy uses a more superficial sclerokeratectomy than NPTS to avoid the risk of perforation. A minitrabeculectomy with cross-linked hyaluronate implant insertion in the sclerokeratectomy site is performed, with several sutures placed in the superficial flap. The sclerokeratectomy site is filled with cohesive viscoelastic substance to avoid a flat or shallow anterior chamber. Using this technique, it is possible to move to NPTS by finding the pre-Descemet's plane in front of the scleral spur and removing the external trabeculum. In case of accidental microperforation of Descemet's plane, the operation is finished as a standard sclerotrabeculectomy with no risk to the patient's eye. A safe transition can thus be achieved. Initial clinical results demonstrate excellent lowering of intraocular pressure without significant complications.
Caronia, Francesco Paolo; Fiorelli, Alfonso; Arrigo, Ettore; Santini, Mario; Castorina, Sergio
2016-05-01
Herein, we reported a catastrophic condition as the almost complete rupture of trachea associated with esophageal lesion following an urgent surgical tracheostomy performed for unexpected difficult intubation. The extent of lesions required a surgical management. We decided against a resection and an end to end anastomosis but preferred to perform a direct suture of the lesion due to the presence of local and systemic infection. Then, the diagnosis of a tracheal fistula led us to perform a direct suture of the defect that was covered with muscle flaps. Actually the patient is alive without problems. Emergency situations as unexpected airway difficult intubation increase morbidity and mortality rate of tracheostomy also in expert hands. Sometimes these events are unpredictable. Mastery with a number of advanced airway technique should be sought when faced dealing with unexpected difficult intubations and written consent of such a concern should be given to the patient.
Laccourreye, Ollivier; Ménard, Madeleine; Behm, Eva; Garcia, Dominique; Cauchois, Régis; Holsinger, F Christopher
2006-11-01
To present the surgical technique and determine the efficacy of sternocleidomastoid myofascial (SCMF) flap reconstruction after composite resection with intent to cure. Retrospective review of 73 consecutive patients with a previously isolated and untreated moderately to well-differentiated invasive squamous cell carcinoma of the tonsillar region and a minimum of 3 years follow-up, managed at a tertiary referral care center during the years 1970 to 2002, with an ipsilateral superiorly based SCMF flap after composite resection. The surgical procedure is presented in detail. Potential technical pitfalls are highlighted. Survival, mortality, and morbidity are documented. Univariate analysis for potential correlation between the incidence for postoperative flap complications and various variables is also performed. The 1, 3, and 5 year Kaplan-Meier actuarial survival estimates were 82.2%, 64.4%, and 49.3%, respectively. Death never appeared to be related to the completion of the SCMF flap. Thirty-three (45.2%) patients had some kind of significant postoperative surgical complication, and nine (12.3%) patients had some kind of significant postoperative medical complication. The most common significant postoperative complication was partial SCMF flap necrosis and pharyngocutaneous fistula noted in 30.1% and 10.9% of patients, respectively. Complete SCMF flap necrosis was never encountered. No patient developed carotid artery rupture or died as a result of the SCMF flap, and none required additional surgery. In univariate analysis, no significant statistical relation was noted between the significant postoperative surgical complications related to the use of the SCMF flap and the variables under analysis. The superiorly based SCMF flap appears to be simple to perform and useful for reconstruction of defects after composite resection.
Delayed lead perforation: a disturbing trend.
Khan, Mohammed N; Joseph, George; Khaykin, Yaariv; Ziada, Khaled M; Wilkoff, Bruce L
2005-03-01
Delayed lead perforation (occurring more than 1 month after implantation) is a rare complication. Its pathophysiology and optimal management are currently unclear. Three cases of delayed lead perforation (6-10 month) were identified in patients with low-profile active fixation leads. All cases presented in a subacute fashion with pleuritic chest pain with confirmatory chest x-ray and device interrogation. Given the potential complications of a perforated lead, all cases had the lead extracted under TEE observation with cardiac surgery backup in the operating room. All patients tolerated extraction without complication. Based on these cases, we recommend a management scheme for patients who present with delayed lead perforation.
Analysis of a Multi-Flap Control System for a Swashplateless Rotor
NASA Technical Reports Server (NTRS)
Sekula, Martin K.; Wilbur, Matthew L.
2011-01-01
An analytical study was conducted examining the feasibility of a swashplateless rotor controlled through two trailing edge flaps (TEF), where the cyclic and collective controls were provided by separate TEFs. This analysis included a parametric study examining the impact of various design parameters on TEF deflections. Blade pitch bearing stiffness; blade pitch index; and flap chord, span, location, and control function of the inboard and outboard flaps were systematically varied on a utility-class rotorcraft trimmed in steady level flight. Gradient-based optimizations minimizing flap deflections were performed to identify single- and two-TEF swashplateless rotor designs. Steady, forward and turning flight analyses suggest that a two-TEF swashplateless rotor where the outboard flap provides cyclic control and inboard flap provides collective control can reduce TEF deflection requirements without a significant impact on power, compared to a single-TEF swashplateless rotor design.
Combined bilateral hatchet and nasolabial advancement flaps for a large defect of the lower lip.
Makiguchi, Takaya; Yokoo, Satoshi; Miyazaki, Hidetaka; Soda, Takashi; Terashi, Hiroto
2013-11-01
A large full-thickness defect of the lower lip is difficult to reconstruct. Preservation of eating and speaking functions based on maintenance of oral sphincter and muscle function, sensation, and the oral aperture are the basic aims. It is also important to achieve a good aesthetic appearance. Here, we describe a new procedure using combined bilateral hatchet and nasolabial advancement flaps for a large full-thickness defect of the lower lip. The aim of use of the hatchet flap is to make a natural curve from the mentolabial fold to the mental protuberance using the "dog ear" resulting from suturing medially advanced bilateral hatchet flaps and to preserve a more certain blood supply to the medial edge of the flap. Our results indicate that the procedure using combined bilateral hatchet flaps and nasolabial flaps is useful for a U-shaped large full-thickness defect, with good functional and aesthetic outcomes.
Use of Pericranial Flaps in the Management of Cranial Base Trauma
Polley, John W.; Penney, Don; Cohen, Mimis
1993-01-01
Pericranial flaps based on the musuloaponeurotic or myofacial layers of the scalp have great utility in the management of acquired and congenital craniofacial deformities. Their use in traumatic deformities is indicated in the presence of craniopharyngeal communications and significant anterior cranial fossa dead space created from frontal sinus obliteration. The indications and operative techniques and the results of the use of these flaps in 10 consecutive patient with extensive cranial base trauma are presented. ImagesFigure 4p49-bFigure 4Figure 5Figure 5p52-b PMID:17170889
Gachabayov, Mahir; Babyshin, Valentin; Durymanov, Oleg; Neronov, Dmitriy
2017-01-01
Perforated gastric ulcer is one of the most life-threatening complications of peptic ulcer disease with high morbidity and mortality rates. The surgical strategy for gastric perforation in contrast with duodenal perforations often requires consilium and intraoperative debates. The subject of the debate is a 59-year-old male patient who presented with perforated giant gastric ulcer complicated by generalized peritonitis and severe sepsis. The debate is based on a systematized table dividing all factors into three groups and putting them on surgical scales. Pathology-related factors influencing the decision-making are size and site of perforation, local tissue inflammation, signs of malignancy, simultaneous complications of peptic ulcer, peritonitis, and sepsis. Besides these factors, patient- and healthcare-related factors should also be considered.
Gachabayov, Mahir; Babyshin, Valentin; Durymanov, Oleg; Neronov, Dmitriy
2017-01-01
Perforated gastric ulcer is one of the most life-threatening complications of peptic ulcer disease with high morbidity and mortality rates. The surgical strategy for gastric perforation in contrast with duodenal perforations often requires consilium and intraoperative debates. The subject of the debate is a 59-year-old male patient who presented with perforated giant gastric ulcer complicated by generalized peritonitis and severe sepsis. The debate is based on a systematized table dividing all factors into three groups and putting them on surgical scales. Pathology-related factors influencing the decision-making are size and site of perforation, local tissue inflammation, signs of malignancy, simultaneous complications of peptic ulcer, peritonitis, and sepsis. Besides these factors, patient- and healthcare-related factors should also be considered. PMID:28584503
Hughes, Kimberley; Neoh, Derek
2018-06-16
Locally advanced breast cancer (LABC) is traditionally treated with a multimodal approach of chemotherapy, surgery, and postmastectomy radiotherapy (PMRT). The advantages of immediate breast reconstruction (IBR) are well described and include improved aesthetic outcomes, fewer surgical procedures, shorter treatment period, and a higher quality of life. However, this sequence makes immediate free autologous reconstruction more challenging as PMRT can have deleterious and unpredictable effects on the flap. We have reversed this treatment sequence with neoadjuvant chemotherapy and radiotherapy, followed by mastectomy and immediate free autologous reconstruction. To our knowledge, this is the first series to assess the outcomes of neoadjuvant radiotherapy on immediate free microvascular breast reconstruction. A review of patients with LABC who underwent immediate free autologous breast reconstruction post neoadjuvant chemoradiotherapy between 2013 and 2017 was conducted. All reconstructions were performed by a single reconstructive team. The primary end points were flap failure and surgical complications. Secondary end points were pathological response rate and disease recurrence. A total of 40 women with an average age of 48.1 (36-61) and average body mass index of 25.6 (18-37) were included. The most common choice of flap was immediate deep inferior epigastric perforator (DIEP, 31), followed by transverse or diagonal upper gracilis (5), muscle-sparing transversus abdominis (3), and stacked DIEP (1). Our major complication rate was 12.5% and minor complication 15%. There were no cases of local recurrence and only three cases (7.5%) of distant disease progression. From our experience, this treatment sequence allows patients to have an immediate gold standard reconstruction without an increase in surgical morbidity. It affords the benefits of IBR without concern in delaying adjuvant therapy and appears to be safe from an oncological perspective. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Faris, Callum; van der Eerden, Paul; Vuyk, Hade
2015-01-01
This study clarifies the pedicle geometry and vascular supply of a midline forehead flap for nasal reconstruction. It reports on the vascular reliability of this flap and its ability to reduce hair transposition to the nose, a major complicating factor of previous forehead flap designs. To compare the vascular reliability of 3 different pedicle designs of the forehead flap in nasal reconstruction (classic paramedian, glabellar paramedian, and central artery flap design) and evaluate hair transposition rates and aesthetic results. Retrospective analysis of patient data and outcomes retrieved from computer files generated at the time of surgery, supplemented by data from the patient medical records and photographic documentation, from a tertiary referral nasal reconstructive practice, within a secondary-care hospital setting. The study population included all consecutive patients over a 19-year period who underwent primary forehead flap repair of nasal defects, with more than 3 months of postoperative follow-up and photographic documentation. Three sequential forehead flap patterns were used (classic paramedian flap, glabella flap, and central artery flap) for nasal reconstruction over the study duration. Data collected included patient characteristics, method of repair, complications, functional outcome, and patient satisfaction score. For cosmetic outcome, photographic documentation was scored by a medical juror. No forehead flap had vascular compromise in the first stage. Partial flap necrosis was reported in subsequent stages in 4 patients (1%), with no statistical difference in the rate of vascular compromise between the 3 flap designs. Hair transposition to the nose was lower in the central artery forehead flap (7%) compared with the classic paramedian (23%) and glabellar paramedian (13%) flaps (P < .05). Photographic evaluation in 227 patients showed that brow position (98%) and color match (83%) were good in the majority of the patients. In this series, the central artery forehead flap was as reliable (in terms of vascularity) as the glabellar and classic paramedian forehead flap. Its use resulted in a statistically significant reduction in transfer of hair to the nose in our series. 3.
Spolyar, John L; Hnatiuk, Mark; Shaheen, Kenneth W; Mertz, Jennifer K; Handler, Lawrence F; Jarial, Ravinder; Roldán, J Camilo
2015-09-01
Repair of facial clefts implies wide tissue mobilization with multi-stage surgical treatment. Authors propose pre-surgical orthopedic correction for naso-oro-ocular clefts and a novel surgical option for Tessier No. 3 cleft. Two male infants, a Tessier No. 3 cleft (age 7 months) and another Tessier No. 4 (age 3 months), were treated with a modified orthopedic Latham device with additional septo-premaxillary molding and observed to age four years. Tessier No. 3 orthopedic measurements were obtained by image corrected cephalometric analysis. Subsequent repair included tissue expansion on Tessier No. 4 and naso-frontal Rieger flap combined with myocutaneous upper lid flap on Tessier No. 3. Orthopedic movements ranged from 18.5 mm in bi-planar to 33 mm in oblique analyses. Tissue margins became aligned with platform normalization. Tissue expansion on Tessier No. 4 improved distances from ala base-lower lid and subalar base-lip. The naso-frontal flap combined with myocutaneous upper lid flap on Tessier No. 3 had similar achievement, but also sufficiently lengthened ala base-canthal distance. Repairs were facilitated by pre-surgical orthopedic correction. The naso-frontal flap combined with an upper lid myocutaneous flap seems viable as a single-stage option to lengthen ala base-canthal distance to advance repair achievement in unilateral Tessier No. 3. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Chang, Edward I; Hanasono, Matthew M; Butler, Charles E
2016-10-01
Complex head and neck reconstruction often mandates free tissue transfer to achieve the most optimal outcomes. Unfortunately, such challenging cases are not without risks of complications, the most dreaded of which is loss of the free flap. Aside from loss of the free flap, there are several other potential complications that can result following head and neck reconstruction. Certain complications are avoided with careful planning, others require significant revisions and in certain cases another free flap. This article presents the experience managing a series of unique complications following free flap head and neck reconstruction. Published by Elsevier Inc.
Reconstruction of posterior neck and skull with vertical trapezius musculocutaneous flap
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mathes, S.J.; Stevenson, T.R.
1988-10-01
The vertical trapezius musculocutaneous flap has been successfully utilized for reconstruction in 13 patients with complex posterior skull and neck defects. This flap based on its vascular pedicle, the descending branch of the transverse cervical artery, provides well-vascularized tissue for coverage of defects related to chronic osteomyelitis, tumor extirpation, osteoradionecrosis, and dehisced cervical laminectomy wounds. Emphasis on flap design, including the location of the skin island, allows adequate wound coverage, direct donor site closure, and muscle function preservation. With its large size and wide arc of rotation, the vertical trapezius musculocutaneous flap provides reliable coverage for posterior trunk, cervical, andmore » skull defects.« less
4D metrology of flapping-wing micro air vehicle based on fringe projection
NASA Astrophysics Data System (ADS)
Zhang, Qican; Huang, Lei; Chin, Yao-Wei; Keong, Lau-Gih; Asundi, Anand
2013-06-01
Inspired by dominant flight of the natural flyers and driven by civilian and military purposes, micro air vehicle (MAV) has been developed so far by passive wing control but still pales in aerodynamic performance. Better understanding of flapping wing flight mechanism is eager to improve MAV's flight performance. In this paper, a simple and effective 4D metrology technique to measure full-field deformation of flapping membrane wing is presented. Based on fringe projection and 3D Fourier analysis, the fast and complex dynamic deformation, including wing rotation and wing stroke, of a flapping wing during its flight can be accurately reconstructed from the deformed fringe patterns recorded by a highspeed camera. An experiment was carried on a flapping-wing MAV with 5-cm span membrane wing beating at 30 Hz, and the results show that this method is effective and will be useful to the aerodynamicist or micro aircraft designer for visualizing high-speed complex wing deformation and consequently aid the design of flapping wing mechanism to enhanced aerodynamic performance.
Moreno-Artero, E; Redondo, P
2015-10-01
A large number of flaps, particularly rotation and transposition flaps, have been described for the closure of skin defects left by oncologic surgery of the nose. The logarithmic spiral flap is a variant of the rotation flap. We present a series of 15 patients with different types of skin tumor on the nose. The skin defect resulting from excision of the tumor by micrographic surgery was reconstructed using various forms of the logarithmic spiral flap. There are 3 essential aspects to flap design: commencement of the pedicle at the upper or lower border of the wound, a width of the distal end of the flap equal to the vertical diameter of the defect, and a progressive increase in the radius of the spiral from the distal end of the flap to its base. The cosmetic and functional results of surgical reconstruction were satisfactory, and no patient required additional treatment to improve scar appearance. The logarithmic spiral flap is useful for the closure of circular or oval defects situated on the lateral surface of the nose and nasal ala. The flap initiates at one of the borders of the wound as a pedicle with a radius that increases progressively to create a spiral. We propose the logarithmic spiral flap as an excellent option for the closure of circular or oval defects of the nose. Copyright © 2015 Elsevier España, S.L.U. and AEDV. All rights reserved.
"All-laser" endothelial corneal transplant in human patients
NASA Astrophysics Data System (ADS)
Rossi, Francesca; Menabuoni, Luca; Malandrini, Alex; Canovetti, Annalisa; Lenzetti, Ivo; Pini, Roberto
2012-03-01
Femtosecond laser sculpturing of corneal tissue is commonly used for the preparation of endothelial flaps. Diode laser welding of ocular tissues is a procedure that enables minimally invasive suturing of tissues. The combination of these laser based techniques results in a new approach to minimally invasive ophthalmic surgery, such as in endothelial corneal transplant (or endothelial keratoplasty - EK). In this work we present the "all laser" EK performed in human subjects. 24 pseudophakic patients with bullous keratopathy underwent EK: the femtosecond laser was used to prepare the 100 ìm thick and 8.5 mm diameter donor Descemet endothelial flap. After staining the stromal layer of the donor flap with a liquid ICG solution, the donor flap was inserted in the recipient eye by the use of the Busin injector. Then, the endothelial layer was laser-welded to the recipient eye (10 laser spots around the periphery of the flap), in order to reduce the risk of postoperative dislocation of the transplanted flap. A transplanted flap engraftment was observed in all the treated eyes. The staining procedure used to perform laser welding also enabled to evidence the stromal side of the donor flap, so as the flap was always placed in the right side position. The endothelial cells counts in both the laserwelded flaps and in a control group were in good agreement. The proposed technique is easy to perform and enables the reduction of postoperative endothelial flap dislocations.
Reyes, Camilo; Mason, Eric; Solares, C. Arturo
2014-01-01
Introduction A substantial body of literature has been devoted to the distinct characteristics and surgical options to repair the skull base. However, the skull base is an anatomically challenging location that requires a three-dimensional reconstruction approach. Furthermore, advances in endoscopic skull base surgery encompass a wide range of surgical pathology, from benign tumors to sinonasal cancer. This has resulted in the creation of wide defects that yield a new challenge in skull base reconstruction. Progress in technology and imaging has made this approach an internationally accepted method to repair these defects. Objectives Discuss historical developments and flaps available for skull base reconstruction. Data Synthesis Free grafts in skull base reconstruction are a viable option in small defects and low-flow leaks. Vascularized flaps pose a distinct advantage in large defects and high-flow leaks. When open techniques are used, free flap reconstruction techniques are often necessary to repair large entry wound defects. Conclusions Reconstruction of skull base defects requires a thorough knowledge of surgical anatomy, disease, and patient risk factors associated with high-flow cerebrospinal fluid leaks. Various reconstruction techniques are available, from free tissue grafting to vascularized flaps. Possible complications that can befall after these procedures need to be considered. Although endonasal techniques are being used with increasing frequency, open techniques are still necessary in selected cases. PMID:25992142
NASA Technical Reports Server (NTRS)
Dicarlo, Daniel J.; Brown, Philip W.; Hallissy, James B.
1992-01-01
Flight tests of an F-106B aircraft equipped with a leading-edge vortex flap, which represented the culmination of a research effort to examine the effectiveness of the flap, were conducted at the NASA Langley Research Center. The purpose of the flight tests was to establish a data base on the use of a wing leading-edge vortex flap as a means to validate the design and analysis methods associated with the development of such a vortical flow-control concept. The overall experiment included: refinements of the design codes for vortex flaps; numerous wind tunnel entries to aid in verifying design codes and determining basic aerodynamic characteristics; design and fabrication of the flaps, structural modifications to the wing tip and leading edges of the test aircraft; development and installation of an aircraft research instrumentation system, including wing and flap surface pressure measurements and selected structural loads measurements; ground-based simulation to assess flying qualities; and finally, flight testing. This paper reviews the operational aspects associated with the flight experiment, which includes a description of modifications to the research airplane, the overall flight test procedures, and problems encountered. Selected research results are also presented to illustrate the accomplishments of the research effort.
Patient-based outcomes following surgical debridement and flap coverage of digital mucous cysts.
Hojo, Junya; Omokawa, Shohei; Shigematsu, Koji; Onishi, Tadanobu; Murata, Keiichi; Tanaka, Yasuhito
2016-01-01
The purpose of this prospective cohort study was to evaluate patient-based outcomes and complications following excision of mucous cysts, joint debridement, and closure with one of three types of local flaps. From 2000-2011, 35 consecutive patients with 37 digital mucous cysts were treated surgically. The surgical procedure included excision of the cyst together with the attenuated skin, joint debridement on the affected side including capsulectomy, and removal of osteophytes. Depending on the size and location of the cyst, the skin defect was covered by a transposition flap (31 cysts), an advancement flap (two cysts), or a rotation flap (four cysts). At an average follow-up time of 4 years, 4 months, there was no wound infection, flap necrosis, or joint stiffness. Preoperative nail ridging resolved in seven of nine fingers, and no nail deformities developed after surgery. One cyst, treated with a transposition flap, recurred 10 months after surgery. The average satisfaction score for the affected finger significantly improved from 4.3 to 6.8, and the average pain score decreased from 4.7 to 2.3. This treatment protocol provides reliable results. Patients were satisfied with the reduction of associated pain and the postoperative appearance of the treated finger, and postoperative complications were minimal.
Dimensional scaling for impact cratering and perforation
NASA Technical Reports Server (NTRS)
Watts, Alan; Atkinson, Dale; Rieco, Steve
1993-01-01
This report summarizes the development of two physics-based scaling laws for describing crater depths and diameters caused by normal incidence impacts into aluminum and TFE Teflon. The report then describes equations for perforations in aluminum and TFE Teflon for normal impacts. Lastly, this report also studies the effects of non-normal incidence on cratering and perforation.
Production frequency effects in perception of phonological variation
NASA Astrophysics Data System (ADS)
Connine, Cynthia M.; Ranbom, Larissa J.
2004-05-01
Two experiments were conducted that investigated the relationship between phonological variant occurrence frequency (based on a corpus analysis of conversational speech) and auditory word recognition. The variant investigated was an alternation between the presence of [nt] and a nasal flap (e.g., center, cen'er). The corpus analysis showed that 80% of productions are nasal flaps, with wide variability across words (from 0% for ``enter'' to 100% for ``twenty''). In a production goodness rating experiment, listeners rated [nt] productions as better than their nasal flap counterparts. For individual items, a strong positive correlation was found between nasal flap frequency and goodness ratings: words typically produced with nasal flaps were rated as better productions. A lexical decision experiment showed that nasal flap variants were recognized more slowly and less accurately than [nt] versions. The rated quality of the nasal-flapped production was strongly correlated with the results of the lexical decision task: nasal-flapped words considered highly acceptable were recognized more quickly and accurately than words rated as poor nasal flap productions. The results demonstrate a strong relationship between experienced variant frequency and auditory word recognition and suggest that phonological variation is explicitly represented in the mental lexicon.
Li, Yiyuan; Zhang, Ruhong; Zhang, Qun; Xu, Zhicheng; Xu, Feng; Li, Datao
2017-02-01
Advances in staged total auricular reconstruction have resulted in improved anterior auricular appearance; however, satisfactory postreconstruction esthetics of the retroauricular fold remain challenging. The postauricular appearance of the reconstructed ear depends largely upon optimizing the covering material. When used as the covering soft tissue for ear elevation, a flap containing primarily the upper portion of the retroauricular fascia has potential advantages over the conventional book cover-type retroauricular fascia flap. We developed a geometrically designed, posterosuperior auricular fascia flap to replace the conventional retroauricular fascia flap for ear elevation. During the second-stage operation, the posterosuperior auricular fascia flap is rotated downward and turned over to wrap around the inner strut and entire posterior auricular surface. Compared to the conventional book cover-type retroauricular fascia flap, the novel posterosuperior auricular fascia flap was easier to harvest and the operative time significantly decreased (110.3 vs. 121.5 min, p < 0.01). The modified flap produced a thin and natural contour of the postauricular surface, as well as reduced the incidence of postauricular hypertrophic scarring (from 24.7 to 13.2%, p = 0.03) and partial skin graft necrosis (from 43.4 to 31.2%, p = 0.01). The geometrically designed posterosuperior auricular fascia flap improves ear elevation. Compared to the conventional book cover-type retroauricular fascia flap, this covering tissue is easier to perform so the surgical time is decreased. It was highly vascularized, well defined, thinner, and yields reliable results. Thus, favorable postauricular surface results can be achieved during auricular reconstruction by using the modified fascia flap. This journal requires that authors assign a level of evidence to each submission to which Evidence-Based Medicine rankings are applicable. This excludes Review Articles, Book Reviews, and manuscripts that concern Basic Science, Animal Studies, Cadaver Studies, and Experimental Studies. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.
Rahpeyma, Amin; khajehahmadi, Saeedeh
2015-01-01
Introduction Reconstruction of oral and pharyngeal defects after pathologic resections with the same tissue is an optimal and ideal target. Islanded variety of inferiorly pedicled facial artery musculomucosal flap, in which facial artery and vein are skeletonized (referred to as inferiorly based BUMIF), is suitable for reconstruction of medium-sized mucosal defects. Presentation of cases In this article, with four cases, modifications of this flap are demonstrated in reconstruction of large intraoral and oropharyngeal defects and coverage of alveolar ridge in the mandible. Discussion In some situations, there is a need for more mucosal paddle, longer vascular pedicle and more adaptation to the recipient bed. Conclusion Relocating Stensen’s duct increases the mucosal paddle with cranial extension of superior limit while differential incision of the mucosa and buccinator muscle in mandibular vestibule extend the lower limit of this flap. Bone suture is a good complementary technique when this flap is used for coverage of mandibular alveolar ridge. Inferiorly based BUMIF with added length is indicated for oropharyngeal and contralateral mouth floor reconstructions. PMID:26218177
Voss, Susan E.; Rosowski, John J.; Merchant, Saumil N.; Peake, William T.
2008-01-01
Direct acoustic stimulation of the cochlea by the sound-pressure difference between the oval and round windows (called the “acoustic route”) has been thought to contribute to hearing in some pathological conditions, along with the normally dominant “ossicular route.” To determine the efficacy of this acoustic route and its constituent mechanisms in human ears, sound pressures were measured at three locations in cadaveric temporal bones [with intact and perforated tympanic membranes (TMs)]: (1) in the external ear canal lateral to the TM, PTM; (2) in the tympanic cavity lateral to the oval window, POW; and (3) near the round window, PRW. Sound transmission via the acoustic route is described by two concatenated processes: (1) coupling of sound pressure from ear canal to middle-ear cavity, HPCAV≡PCAV/PTM, where PCAV represents the middle-ear cavity pressure, and (2) sound-pressure difference between the windows, HWPD≡(POW−PRW)/PCAV. Results show that: HPCAV depends on perforation size but not perforation location; HWPD depends on neither perforation size nor location. The results (1) provide a description of the window pressures based on measurements, (2) refute the common otological view that TM perforation location affects the “relative phase of the pressures at the oval and round windows,” and (3) show with an intact ossicular chain that acoustic-route transmission is substantially below ossicular-route transmission except for low frequencies with large perforations. Thus, hearing loss from TM perforations results primarily from reduction in sound coupling via the ossicular route. Some features of the frequency dependence of HPCAV and HWPD can be interpreted in terms of a structure-based lumped-element acoustic model of the perforation and middle-ear cavities. PMID:17902851
Laparoscopic repair of perforated peptic duodenal ulcer.
Busić, Zeljko; Servis, Draien; Slisurić, Ferdinand; Kristek, Jozo; Kolovrat, Marijan; Cavka, Vlatka; Cavka, Mislav; Cupurdija, Kristijan; Patrlj, Leonardo; Kvesić, Ante
2010-03-01
Although prevalence of peptic ulcer is decreasing, the number of peptic ulcer perforations appears to be unchanged. This complication of peptic ulcer is traditionally surgically treated. In recent years, a number of papers have been published where the authors managed perforated duodenal peptic ulcer in selected patients using laparoscopic approach. Laparoscopic treatment of perforated duodenal ulcer has been described as safe and advantageous compared to open technique but advantages are still not clear due to small number of cases in published studies. Based on these recommendations we decided to establish our own protocol for laparoscopic treatment of perforated peptic duodenal ulcer. In this prospective study we evaluated the first 10 patients in whom we performed laparoscopic repair of perforated duodenal ulcer. There were no conversions to open procedure and no early postoperative complications. The patients were contacted by phone a year after the operation, and all were satisfied with the operation and the appearance of postoperative scars. We regard laparoscopic repair of selected patients with perforated duodenal ulcer as a safe and preferable treatment.
NASA Astrophysics Data System (ADS)
Mohamad, Firdaus; Wisnoe, Wirachman; Nasir, Rizal E. M.; Kuntjoro, Wahyu
2012-06-01
This paper discusses on the split drag flaps to the yawing motion of BWB aircraft. This study used split drag flaps instead of vertical tail and rudder with the intention to generate yawing moment. These features are installed near the tips of the wing. Yawing moment is generated by the combination of side and drag forces which are produced upon the split drag flaps deflection. This study is carried out using Computational Fluid Dynamics (CFD) approach and applied to low subsonic speed (0.1 Mach number) with various sideslip angles (β) and total flaps deflections (δT). For this research, the split drag flaps deflections are varied up to ±30°. Data in terms of dimensionless coefficient such as drag coefficient (CD), side coefficient (CS) and yawing moment coefficient (Cn) were used to observe the effect of the split drag flaps. From the simulation results, these split drag flaps are proven to be effective from ±15° deflections or 30° total deflections.
Laparoscopic versus open-component separation: a comparative analysis in a porcine model.
Rosen, Michael J; Williams, Christina; Jin, Judy; McGee, Michael F; Schomisch, Steve; Marks, Jeffrey; Ponsky, Jeffrey
2007-09-01
The ideal surgical treatment for complicated ventral hernias remains elusive. Traditional component separation provides local advancement of native tissue for tension-free closure without prosthetic materials. This technique requires an extensive subcutaneous dissection with division of perforating vessels predisposing to skin-flap necrosis and complicated wound infections. A minimally invasive component separation may decrease wound complication rates; however, the adequacy of the myofascial advancement has not been studied. Five 25-kg pigs underwent bilateral laparoscopic component separation. A 10-mm incision was made lateral to the rectus abdominus muscle. The external oblique fascia was incised, and a dissecting balloon was inflated between the internal and external oblique muscles. Two additional ports were placed in the intermuscular space. The external oblique was incised from the costal margin to the inguinal ligament. The maximal abdominal wall advancement was recorded. A formal open-component separation was performed and maximal advancement 5 cm superior and 5 cm inferior to the umbilicus was recorded for comparison. Groups were compared using standard statistical analysis. The laparoscopic component separation was completed successfully in all animals, with a mean of 22 min/side. Laparoscopic component separation yielded 3.9 cm (SD 1.1) of fascial advancement above the umbilicus, whereas 4.4 cm (1.2) was obtained after open release (P = .24). Below the umbilicus, laparoscopic release achieved 5.0 cm (1.0) of advancement, whereas 5.8 cm (1.2) was gained after open release (P = .13). The minimally invasive component separation achieved an average of 86% of the myofascial advancement compared with a formal open release. The laparoscopic approach does not require extensive subcutaneous dissection and might theoretically result in a decreased incidence or decreased complexity of postoperative wound infections or skin-flap necrosis. Based on our preliminary data in this porcine model, further comparative studies of laparoscopic versus open component separation in complex ventral hernia repair is warranted to evaluate postoperative morbidity and long-term hernia recurrence rates.
Ramasamy, P R
2017-01-01
Open fractures of tibia have posed great difficulty in managing both the soft tissue and the skeletal components of the injured limb. Gustilo Anderson III B open tibial fractures are more difficult to manage than I, II, and III A fractures. Stable skeletal fixation with immediate soft tissue cover has been the key to the successful outcome in treating open tibial fractures, in particular, Gustilo Anderson III B types. If the length of the open wound is larger and if the exposed surface of tibial fracture and tibial shaft is greater, then the management becomes still more difficult. Thirty six Gustilo Anderson III B open tibial fractures managed between June 2002 and December 2013 with "fix and shift" technique were retrospectively reviewed. All the 36 patients managed by this technique had open wounds measuring >5 cm (post debridement). Under fix and shift technique, stable fixation involved primary external fixator application or primary intramedullary nailing of the tibial fracture and immediate soft tissue cover involved septocutaneous shift, i.e., shifting of fasciocutaneous segments based on septocutaneous perforators. Primary fracture union rate was 50% and reoperation rate (bone stimulating procedures) was 50%. Overall fracture union rate was 100%. The rate of malunion was 14% and deep infection was 16%. Failure of septocutaneous shift was 2.7%. There was no incidence of amputation. Management of Gustilo Anderson III B open tibial fractures with "fix and shift" technique has resulted in better outcome in terms of skeletal factors (primary fracture union, overall union, and time for union and malunion) and soft tissue factors (wound healing, flap failure, access to secondary procedures, and esthetic appearance) when compared to standard methods adopted earlier. Hence, "fix and shift" could be recommended as one of the treatment modalities for open III B tibial fractures.
[Precision of navigation-assisted surgery of the thoracic and lumbar spine].
Arand, M; Schempf, M; Hebold, D; Teller, S; Kinzl, L; Gebhard, F
2003-11-01
The goal of these studies was to evaluate the accuracy of in vivo and in vitro application of CT- and C-arm-based navigation at the thoracic and lumbar spine. With CT based navigation, 82 pedicle screws were consecutively inserted, 53 into the thoracic and 29 into the lumbar spine. Seven (13%) perforations were detected at the thoracic spine and two (7%) at the lumbar spine. Additionally, minor perforations below the thread depth were seen in six (11%) thoracic and in two (7%) lumbar instrumentation. With C-arm-based navigation, 74 screws were consecutively placed into 38 thoracic and 36 lumbar pedicles. Perforations were noted in ten (26%) thoracic and four (11%) lumbar implants. Minor perforations were observed in another nine (24%) thoracic and ten (28%) lumbar pedicles. The observer-independent and standardized in vitro study based on a transpedicular 3.2-mm drill hole aiming a 4-mm steel ball in a plastic bone model showed pedicle perforations of the drill canal only in thoracic vertebrae, 1 of 15 in CT-based and 3 of 15 in C-arm navigation. The quantitative calculation of the smallest distance between the central line through the drill canal and the center of the steel ball resulted in 1.4 mm (0.5-4.8 mm) for the CT-based navigation at the thoracic spine and in 1.8 mm (0.5-3 mm) at the lumbar spine. For the C-arm based navigation the distance was 2.6 mm (0.9-4.8 mm) for the thoracic spine and 2 mm (1.2-3 mm) for the lumbar spine. In our opinion, the clinical results of the comparative accuracy of CT- and C-arm-based navigation in the present study showed moderate advantages of the CT-based technique in the thoracic spine, whereas CT- and C-arm based navigation had comparable perforation rates at the lumbar pedicle. The results of the experimental study correlated with the clinical data.
Superfast high-resolution absolute 3D recovery of a stabilized flapping flight process.
Li, Beiwen; Zhang, Song
2017-10-30
Scientific research of a stabilized flapping flight process (e.g. hovering) has been of great interest to a variety of fields including biology, aerodynamics, and bio-inspired robotics. Different from the current passive photogrammetry based methods, the digital fringe projection (DFP) technique has the capability of performing dense superfast (e.g. kHz) 3D topological reconstructions with the projection of defocused binary patterns, yet it is still a challenge to measure a flapping flight process with the presence of rapid flapping wings. This paper presents a novel absolute 3D reconstruction method for a stabilized flapping flight process. Essentially, the slow motion parts (e.g. body) and the fast-motion parts (e.g. wings) are segmented and separately reconstructed with phase shifting techniques and the Fourier transform, respectively. The topological relations between the wings and the body are utilized to ensure absolute 3D reconstruction. Experiments demonstrate the success of our computational framework by testing a flapping wing robot at different flapping speeds.
Aerodynamic comparison of a butterfly-like flapping wing-body model and a revolving-wing model
NASA Astrophysics Data System (ADS)
Suzuki, Kosuke; Yoshino, Masato
2017-06-01
The aerodynamic performance of flapping- and revolving-wing models is investigated by numerical simulations based on an immersed boundary-lattice Boltzmann method. As wing models, we use (i) a butterfly-like model with a body and flapping-rectangular wings and (ii) a revolving-wing model with the same wings as the flapping case. Firstly, we calculate aerodynamic performance factors such as the lift force, the power, and the power loading of the two models for Reynolds numbers in the range of 50-1000. For the flapping-wing model, the power loading is maximal for the maximum angle of attack of 90°, a flapping amplitude of roughly 45°, and a phase shift between the flapping angle and the angle of attack of roughly 90°. For the revolving-wing model, the power loading peaks for an angle of attack of roughly 45°. In addition, we examine the ground effect on the aerodynamic performance of the revolving-wing model. Secondly, we compare the aerodynamic performance of the flapping- and revolving-wing models at their respective maximal power loadings. It is found that the revolving-wing model is more efficient than the flapping-wing model both when the body of the latter is fixed and where it can move freely. Finally, we discuss the relative agilities of the flapping- and revolving-wing models.
Supraclavicular Artery Flap for Head and Neck Oncologic Reconstruction: An Emerging Alternative
Shenoy, Ashok; Patil, Vijayraj S.; Prithvi, B. S.; Chavan, P.; Halkud, Rajshekar
2013-01-01
Aim. Head and Neck oncologic resections often leave complex defects which are challenging to reconstruct. The need of the hour is a versatile flap which has the advantages of both a regional flap (viz. reliable and easy to harvest) and a free flap (thin, pliable with good colour match). In this a study we assessed the usefulness of the supraclavicular artery flap in head and neck oncologic defects. Materials and Method. The flap was used as a pedicled fasciocutanous and was based on the transverse supraclavicular artery. We assessed this reconstructive option for complications as well as its and functional out comes. Results. Eleven cases underwent supraclavicular artery flap between 20011-2012 of which 5 were males and 6 females. Mean defect size was 5 cm × 6 cm. Nine donor sites were closed primarily and 1 required split skin grafting. We encountered one complete flap loss which was attributed to a band of constricting skin bridge over the vascular pedicle in a defect involving lateral third of midface. Two patient developed pharyngeocutaneous fistula (without flap loss) out of 3 patients who underwent augmentation pharyngoplasty post Near total laryngectomy. Conclusion. Supra clavicular artery flap is a thin versatile, reliable, easy to harvest, with good cosmetic and functional outcome at both ends (recipient and donor) for reconstructing head and neck oncologic defects. PMID:24490064
Dorafshar, Amir H; Januszyk, Michael; Song, David H
2010-08-01
Techniques for autologous breast reconstruction have evolved to minimize donor-site morbidity and reduce flap-specific complications. When available, the superficial inferior epigastric artery (SIEA) flap represents the optimal method to achieve the former. However, many microsurgeons have been reluctant to adopt this procedure due to technical challenges inherent to the surgery, as well as concerns with the intrinsic capacity of the superficial vessel system to adequately support this flap. This article sets forth a simple approach to the SIEA flap harvest and demonstrates that favorable results may be achieved even for small caliber vessels. A total of 46 patients underwent 53 SIEA breast reconstructions over a 6-year period using a modified approach for pedicle dissection and arterial inclusion criteria solely on the basis of presence of a palpable pulse. Average pedicle length harvested for all SIEA flaps was 6.07 cm; and mean arterial (0.96 mm) and venous (2.27 mm) diameters represent the lowest published values. Three flaps (5.7%) demonstrated fat necrosis or partial flap necrosis, with one (1.9%) complete flap loss. These results compare favorably with those of previous SIEA series employing diameter-based selection criteria, suggesting that the presence of a palpable arterial pulse may be sufficient to permit successful utilization of this flap. (c) Thieme Medical Publishers.
Persson, S; Rouvelas, I; Irino, T; Lundell, L
2017-12-01
Leakage from the esophagus and gastroesophageal junction can be lethal due to uncontrolled contamination of the mediastinum. The most predominant risk factors for the subsequent clinical outcome are the patients' delay as well as the delay of diagnosis. Two major therapeutic concepts have been advocated: either prompt closure of the leakage by insertion of a self-expandable metal stent (SEMS) or more traditionally, surgical exploration. The objective of this review is to carefully scrutinize the recent literature and assess the outcomes of these two therapeutic alternatives in the management of iatrogenic perforation-spontaneous esophageal rupture as separated from those with anastomotic leak. A systematic web-based search using PubMed and the Cochrane Library was performed, reviewing literature published between January 2005 and December 2015. Eligible studies included all studies that presented data on the outcome of SEMS or surgical exploration in case of esophageal leak (including >3 patients). Only patients older than 15 years of age by the time of admission were included. Articles in other languages but English were excluded. Treatment failure was defined as a need for change in therapeutic strategy due to uncontrolled sepsis and mediastinitis, which usually meant rescue esophagectomy with end esophagostomy, death occurring as a consequence of the leakage or development of an esophagorespiratory fistula and/or other serious life threatening complications. Accordingly, the corresponding success rate is composed of cases where none of the failures above occurred. Regarding SEMS treatment, 201 articles were found, of which 48 were deemed relevant and of these, 17 articles were further analyzed. As for surgical management, 785 articles were retrieved, of which 82 were considered relevant, and 17 were included in the final analysis. It was not possible to specifically extract detailed clinical outcomes in sufficient numbers, when we tried to separately analyze the data in relation to the cause of the leakage: i.e. iatrogenic perforation-spontaneous esophageal rupture and anastomotic leak. As for SEMS treatment, originally 154 reports focused on iatrogenic perforation, 116 focused on spontaneous ruptures, and only four described the outcome following trauma and foreign body management. Only five studies used a prospective protocol to assess treatment efficacy. Regarding a leaking anastomosis, 80 reports contained information about the outcome after treatment of esophagogastrostomies and 35 reported the clinical course after an esophagojejunostomy. An overall success rate of 88% was reported among the 371 SEMS-treated patients, where adequate data were available, with a reported in hospital mortality amounting to 7.5%. Regarding the surgical exploration strategy, the vast majority of patients had an attempt to repair the defect by direct or enforced suturing. This surgical approach also included procedures such as patching with pleura or with a diaphragmatic flap. The overall reported success rate was 83% (305/368) and the in-hospital mortality was 17% (61/368). The current literature suggests that a SEMS-based therapy can be successfully applied as an alternative therapeutic strategy in esophageal perforation rupture. © The Authors 2017. Published by Oxford University Press on behalf of International Society for Diseases of the Esophagus. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
An Adjoint-Based Approach to Study a Flexible Flapping Wing in Pitching-Rolling Motion
NASA Astrophysics Data System (ADS)
Jia, Kun; Wei, Mingjun; Xu, Min; Li, Chengyu; Dong, Haibo
2017-11-01
Flapping-wing aerodynamics, with advantages in agility, efficiency, and hovering capability, has been the choice of many flyers in nature. However, the study of bio-inspired flapping-wing propulsion is often hindered by the problem's large control space with different wing kinematics and deformation. The adjoint-based approach reduces largely the computational cost to a feasible level by solving an inverse problem. Facing the complication from moving boundaries, non-cylindrical calculus provides an easy extension of traditional adjoint-based approach to handle the optimization involving moving boundaries. The improved adjoint method with non-cylindrical calculus for boundary treatment is first applied on a rigid pitching-rolling plate, then extended to a flexible one with active deformation to further increase its propulsion efficiency. The comparison of flow dynamics with the initial and optimal kinematics and deformation provides a unique opportunity to understand the flapping-wing mechanism. Supported by AFOSR and ARL.
Aerodynamic analysis of natural flapping flight using a lift model based on spanwise flow
NASA Astrophysics Data System (ADS)
Alford, Lionel D., Jr.
This study successfully described the mechanics of flapping hovering flight within the framework of conventional aerodynamics. Additionally, the theory proposed and supported by this research provides an entirely new way of looking at animal flapping flight. The mechanisms of biological flight are not well understood, and researchers have not been able to describe them using conventional aerodynamic forces. This study proposed that natural flapping flight can be broken down into a simplest model, that this model can then be used to develop a mathematical representation of flapping hovering flight, and finally, that the model can be successfully refined and compared to biological flapping data. This paper proposed a unique theory that the lift of a flapping animal is primarily the result of velocity across the cambered span of the wing. A force analysis was developed using centripetal acceleration to define an acceleration profile that would lead to a spanwise velocity profile. The force produced by the spanwise velocity profile was determined using a computational fluid dynamics analysis of flow on the simplified wing model. The overall forces on the model were found to produce more than twice the lift required for hovering flight. In addition, spanwise lift was shown to generate induced drag on the wing. Induced drag increased both the model wing's lift and drag. The model allowed the development of a mathematical representation that could be refined to account for insect hovering characteristics and that could predict expected physical attributes of the fluid flow. This computational representation resulted in a profile of lift and drag production that corresponds to known force profiles for insect flight. The model of flapping flight was shown to produce results similar to biological observation and experiment, and these results can potentially be applied to the study of other flapping animals. This work provides a foundation on which to base further exploration and hypotheses regarding flapping flight.
Fundamental principles in periodontal plastic surgery and mucosal augmentation--a narrative review.
Burkhardt, Rino; Lang, Niklaus P
2014-04-01
To provide a narrative review of the current literature elaborating on fundamental principles of periodontal plastic surgical procedures. Based on a presumptive outline of the narrative review, MESH terms have been used to search the relevant literature electronically in the PubMed and Cochrane Collaboration databases. If possible, systematic reviews were included. The review is divided into three phases associated with periodontal plastic surgery: a) pre-operative phase, b) surgical procedures and c) post-surgical care. The surgical procedures were discussed in the light of a) flap design and preparation, b) flap mobilization and c) flap adaptation and stabilization. Pre-operative paradigms include the optimal plaque control and smoking counselling. Fundamental principles in surgical procedures address basic knowledge in anatomy and vascularity, leading to novel appropriate flap designs with papilla preservation. Flap mobilization based on releasing incisions can be performed up to 5 mm. Flap adaptation and stabilization depend on appropriate wound bed characteristics, undisturbed blood clot formation, revascularization and wound stability through adequate suturing. Delicate tissue handling and tension free wound closure represent prerequisites for optimal healing outcomes. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.