Sample records for performance cutting technique

  1. Improvement of cutting performance for thick stainless steel plates by step-like cutting speed increase in high-power fiber laser cutting

    NASA Astrophysics Data System (ADS)

    Seon, Sangwoo; Shin, Jae Sung; Oh, Seong Yong; Park, Hyunmin; Chung, Chin-Man; Kim, Taek-Soo; Lee, Lim; Lee, Jonghwan

    2018-07-01

    A study was conducted to improve the cutting performance of a 60-mm thick stainless steel plate using a 6-kW fiber laser. Two techniques for improving the initial cutting performance were evaluated by preheating the work piece with a waiting time and step-like cutting speed increase. Both techniques showed improved cutting results compared to constant speed cutting. Among them, the method with a step-like cutting speed increase showed the better result in terms of cutting performance. As a result, a 60-mm thick stainless steel plate was cut at a maximum cutting speed of 72 mm/min with a preheating cutting speed of 24 mm/min. In order to confirm the effect of preheating, an additional experiment was performed to measure the temperature variation during the cutting process. Through this experiment, preheating temperature conditions were found to allow the specimen to be cut. It is expected that the results of this work will contribute to improving the cutting performance of thick metal structures in various industrial fields, as well as the dismantling of nuclear facilities using lasers in the future.

  2. Early institution of pre-cutting for difficult biliary cannulation: a prospective study comparing conventional vs. a modified technique.

    PubMed

    Kaffes, Arthur J; Sriram, Parupudi V J; Rao, Guduru V; Santosh, Darisetti; Reddy, D Nageshwar

    2005-11-01

    Pre-cutting techniques have been used to gain biliary access at the expense of an increased complication rate. This may be because of the multiple attempts to achieve cannulation by using standard methods before pre-cutting and causing excess edema and papillary trauma. There are limited data on the early use of pre-cutting techniques. We performed a prospective study of the early introduction of needle-knife techniques in patients with difficult biliary cannulation. Standard biliary cannulation was attempted with a sphincterotome and a guidewire. If this failed within 10 minutes or if there were more than 5 pancreatic cannulations, the needle-knife technique was used. Either a standard method of pre-cutting (below-upward) from the papillary orifice or the modified technique of pre-cutting (above-downward), stopping short of the papillary orifice, was adopted, as per the discretion of the endoscopist. If pre-cutting failed, the cannulation was reattempted 24 to 48 hours later. A total of 346 therapeutic biliary ERCP procedures were performed between April and August 2003. Of these, 70 patients (20%) (mean age, 54 years; 38 men) underwent needle-knife pre-cut sphincterotomy (16 with the standard technique). In 58 patients (83%), the procedure was successful with the initial pre-cutting, making the total success at initial ERCP 334/346 (96.5%). Nine patients in whom pre-cut failed, returned for a second-attempt ERCP, with 7 completed successfully. The total success rate of pre-cutting was 65/70 (93%). The overall success rate of biliary cannulation, after two ERCP attempts, was 341/346 (98.5%). Six patients had mild bleeding, and one had mild pancreatitis. There was no difference in these complications between the two types of pre-cut techniques. The early use of needle knife for difficult biliary cannulation is safe and effective, irrespective of the technique used.

  3. Extreme Learning Machine and Particle Swarm Optimization in optimizing CNC turning operation

    NASA Astrophysics Data System (ADS)

    Janahiraman, Tiagrajah V.; Ahmad, Nooraziah; Hani Nordin, Farah

    2018-04-01

    The CNC machine is controlled by manipulating cutting parameters that could directly influence the process performance. Many optimization methods has been applied to obtain the optimal cutting parameters for the desired performance function. Nonetheless, the industry still uses the traditional technique to obtain those values. Lack of knowledge on optimization techniques is the main reason for this issue to be prolonged. Therefore, the simple yet easy to implement, Optimal Cutting Parameters Selection System is introduced to help the manufacturer to easily understand and determine the best optimal parameters for their turning operation. This new system consists of two stages which are modelling and optimization. In modelling of input-output and in-process parameters, the hybrid of Extreme Learning Machine and Particle Swarm Optimization is applied. This modelling technique tend to converge faster than other artificial intelligent technique and give accurate result. For the optimization stage, again the Particle Swarm Optimization is used to get the optimal cutting parameters based on the performance function preferred by the manufacturer. Overall, the system can reduce the gap between academic world and the industry by introducing a simple yet easy to implement optimization technique. This novel optimization technique can give accurate result besides being the fastest technique.

  4. The effect of technique change on knee loads during sidestep cutting.

    PubMed

    Dempsey, Alasdair R; Lloyd, David G; Elliott, Bruce C; Steele, Julie R; Munro, Bridget J; Russo, Kylie A

    2007-10-01

    To identify the effect of modifying sidestep cutting technique on knee loads and predict what impact such change would have on the risk of noncontact anterior cruciate ligament injury. A force platform and motion-analysis system were used to record ground-reaction forces and track the trajectories of markers on 15 healthy males performing sidestep cutting tasks using their normal technique and nine different imposed techniques. A kinematic and inverse dynamic model was used to calculate the three-dimensional knee postures and moments. The imposed techniques of foot wide and torso leaning in the opposite direction to the cut resulted in increased peak valgus moments experienced in weight acceptance. Higher peak internal rotation moments were found for the foot wide and torso rotation in the opposite direction to the cut techniques. The foot rotated in technique resulted in lower mean flexion/extension moments, whereas the foot wide condition resulted in higher mean flexion/extension moments. The flexed knee, torso rotated in the opposite direction to the cut and torso leaning in the same direction as the cut techniques had significantly more knee flexion at heel strike. Sidestep cutting technique had a significant effect on loads experienced at the knee. The techniques that produced higher valgus and internal rotation moments at the knee, such as foot wide, torso leaning in the opposite direction to the cut and torso rotating in the opposite direction to the cut, may place an athlete at higher risk of injury because these knee loads have been shown to increase the strain on the anterior cruciate ligament. Training athletes to avoid such body positions may result in a reduced risk of noncontact anterior cruciate ligament injures.

  5. Overview of nanofluid application through minimum quantity lubrication (MQL) in metal cutting process

    NASA Astrophysics Data System (ADS)

    Sharif, Safian; Sadiq, Ibrahim Ogu; Suhaimi, Mohd Azlan; Rahim, Shayfull Zamree Abd

    2017-09-01

    Pollution related activities in addition to handling cost of conventional cutting fluid application in metal cutting industry has generated a lot of concern over time. The desire for a green machining environment which will preserve the environment through reduction or elimination of machining related pollution, reduction in oil consumption and safety of the machine operators without compromising an efficient machining process led to search for alternatives to conventional cutting fluid. Amongst the alternatives of dry machining, cryogenic cooling, high pressure cooling, near dry or minimum quantity lubrication (MQL), MQL have shown remarkable performance in terms of cost, machining output, safety of environment and machine operators. However, the MQL under aggressive machining or very high speed machining pose certain restriction as the lubrication media cannot perform efficiently at elevated temperature. In compensating for the shortcomings of MQL technique, high thermal conductivity nanoparticles are introduced in cutting fluids for use in the MQL lubrication process. They have indicated enhanced performance of machining process and significant reduction of loads on the environment. The present work is aimed at evaluating the application and performance of nanofluid in metal cutting process through MQL lubrication technique highlighting their impacts and prospects as lubrication strategy in metal cutting process for sustainable green manufacturing. Enhanced performance of vegetable oil based nanofluids over mineral oil-based nanofluids have been reported and thus highlighted.

  6. Study on Circular Complex viewed from Environmental Systems

    NASA Astrophysics Data System (ADS)

    Takeguchi, Tomoo; Adachi, Katsushige; Yoshikawa, Akira; Hiratsuka, Akira; Tsujino, Ryoji; Iguchi, Manabu

    In machining processes, cutting fluids are generally used for cooling and lubricating workpieces at the point cutting. However, these fluids frequently include chlorine, sulfur, phosphorus, or other additives. The chemicals not only become a mist affecting the health of workers engaged in the processing but also make the workshop environment worse. In particular, the chlorine becomes one of the causes of global warming by treating waste oil under high temperature conditions. It is furthermore said that huge cost beyond the purchase cost of oil occurs and dioxins (carcinogen) usually exist in the waste oil. Therefore, an environmentally-friendly cooling-air cutting system is required from the standpoint of green manufacturing. This system has been noted as a technique to solve the issues against the environment mentioned above. In the cooling-air cutting processing, the amount of CO2 emission shows a low value compared with the dry cutting one which uses oil. It is therefore thought that the cooling-air cutting system is a very important processing technique as an environmental countermeasure. At present, in strictly economic and environmental situations, the compatibility of the betterment of production efficiency with the improvement of environment is a subject in the actual spot of a cut processing. This study deals with the test results of cooling-air drilling performance from the viewpoint of taking green manufacturing into account. The workpiece made of die steel SKDll was manufactured by the cooling-air drilling performance at a revolution of 840 rpm and a temperature of -20°C with a high-speed steel drill (SKH56). The results were compared with those for the dry cutting performance. The main results obtained in this study are as follows: 1) The tool life for cooling-air drilling performance was about 6 times as long as that for the dry cutting performance. 2) The chip temperature for cooling-air drilling was 220°C lower than that for the dry cutting performance.

  7. Cut-it-out technique for ocular fish-hook injury.

    PubMed

    Ahmad, Syed Shoeb; Seng, Chiang Wai; Ghani, Shuaibah Abdul; Lee, Jane F

    2013-10-01

    An 11-year-old boy was involved in an injury with a fish-hook to his eye. The hook had impaled itself to the cornea and deeper structures. There was associated corneal edema and hyphema, making visualization difficult. In this case, we performed the unusual "cut-it-out" technique to remove the hook from the eye.

  8. Performance Monitoring Of A Computer Numerically Controlled (CNC) Lathe Using Pattern Recognition Techniques

    NASA Astrophysics Data System (ADS)

    Daneshmend, L. K.; Pak, H. A.

    1984-02-01

    On-line monitoring of the cutting process in CNC lathe is desirable to ensure unattended fault-free operation in an automated environment. The state of the cutting tool is one of the most important parameters which characterises the cutting process. Direct monitoring of the cutting tool or workpiece is not feasible during machining. However several variables related to the state of the tool can be measured on-line. A novel monitoring technique is presented which uses cutting torque as the variable for on-line monitoring. A classifier is designed on the basis of the empirical relationship between cutting torque and flank wear. The empirical model required by the on-line classifier is established during an automated training cycle using machine vision for off-line direct inspection of the tool.

  9. Improving semi-automated segmentation by integrating learning with active sampling

    NASA Astrophysics Data System (ADS)

    Huo, Jing; Okada, Kazunori; Brown, Matthew

    2012-02-01

    Interactive segmentation algorithms such as GrowCut usually require quite a few user interactions to perform well, and have poor repeatability. In this study, we developed a novel technique to boost the performance of the interactive segmentation method GrowCut involving: 1) a novel "focused sampling" approach for supervised learning, as opposed to conventional random sampling; 2) boosting GrowCut using the machine learned results. We applied the proposed technique to the glioblastoma multiforme (GBM) brain tumor segmentation, and evaluated on a dataset of ten cases from a multiple center pharmaceutical drug trial. The results showed that the proposed system has the potential to reduce user interaction while maintaining similar segmentation accuracy.

  10. Theoretical and experimental aspects of laser cutting with a direct diode laser

    NASA Astrophysics Data System (ADS)

    Costa Rodrigues, G.; Pencinovsky, J.; Cuypers, M.; Duflou, J. R.

    2014-10-01

    Recent developments in beam coupling techniques have made it possible to scale up the power of diode lasers with a laser beam quality suitable for laser cutting of metal sheets. In this paper a prototype of a Direct Diode Laser (DDL) source (BPP of 22 mm-mrad) is analyzed in terms of efficiency and cut performance and compared with two established technologies, CO2 and fiber lasers. An analytical model based on absorption calculations is used to predict the performance of the studied laser source with a good agreement with experimental results. Furthermore results of fusion cutting of stainless steel and aluminium alloys as well as oxygen cutting of structural steel are presented, demonstrating that industrial relevant cutting speeds with high cutting quality can now be achieved with DDL.

  11. Investigation of machinability characteristics on EN47 steel for cutting force and tool wear using optimization technique

    NASA Astrophysics Data System (ADS)

    M, Vasu; Shivananda Nayaka, H.

    2018-06-01

    In this experimental work dry turning process carried out on EN47 spring steel with coated tungsten carbide tool insert with 0.8 mm nose radius are optimized by using statistical technique. Experiments were conducted at three different cutting speeds (625, 796 and 1250 rpm) with three different feed rates (0.046, 0.062 and 0.093 mm/rev) and depth of cuts (0.2, 0.3 and 0.4 mm). Experiments are conducted based on full factorial design (FFD) 33 three factors and three levels. Analysis of variance is used to identify significant factor for each output response. The result reveals that feed rate is the most significant factor influencing on cutting force followed by depth of cut and cutting speed having less significance. Optimum machining condition for cutting force obtained from the statistical technique. Tool wear measurements are performed with optimum condition of Vc = 796 rpm, ap = 0.2 mm, f = 0.046 mm/rev. The minimum tool wear observed as 0.086 mm with 5 min machining. Analysis of tool wear was done by confocal microscope it was observed that tool wear increases with increasing cutting time.

  12. Evolution of treatment of fistula in ano.

    PubMed

    Blumetti, J; Abcarian, A; Quinteros, F; Chaudhry, V; Prasad, L; Abcarian, H

    2012-05-01

    Fistula-in-ano is a common medical problem affecting thousands of patients annually. In the past, the options for treatment of fistula-in-ano were limited to fistulotomy and/or seton placement. Current treatment options also include muscle-sparing techniques such as a dermal island flap, endorectal advancement flap, fibrin sealent injection, anal fistula plug, and most recently ligation of the intersphincteric fistula tract (procedure). This study seeks to evaluate types and time trends for treatment of fistula-in-ano. A retrospective review from 1975 to 2009 was performed. Data were collected and sorted into 5-year increments for type and time trends of treatment. Fistulotomy and partial fistulotomy were grouped as cutting procedures. Seton placement, fibrin sealant, dermal flap, endorectal flap, and fistula plug were grouped as noncutting procedures. Statistical analysis was performed for each time period to determine trends. With institutional review board approval, the records of 2,267 fistula operations available for analysis were included. Most of the patients were men (74 vs. 26%). Cutting procedures comprised 66.6% (n = 1510) of all procedures. Noncutting procedures were utilized in 33.4% (n = 757), including Seton placement alone 370 (16.3%), fibrin sealant 168 (7.4%), dermal or endorectal flap 147 (6.5%), and fistula plug 72 (3.2%). The distribution of operations grouped in 5-year intervals is as follows: 1975-1979, 78 cutting and one noncutting; 1980-1984, 170 cutting and 10 noncutting; 1985-1989, 54 cutting and five noncutting; 1990-1994, 37 cutting and six noncutting; 1995-1999, 367 cutting and 167 noncutting; 2000-2004, 514 cutting and 283 noncutting; 2005-2009, 290 cutting and 285 noncutting. The percentage of cutting and noncutting procedures significantly differed over time, with cutting procedures decreasing and noncutting procedures increasing proportionally (χ(2) linear-by-linear association, p < 0.05). Fistula-in-ano remains a common complex disease process. Its treatment has evolved to include a variety of noncutting techniques in addition to traditional fistulotomy. With the advent of more sphincter-sparing techniques, the number of patients undergoing fistulotomy should continue to decrease over time. Surgeons should become familiar with various surgical techniques so the treatment can be tailored to the patient.

  13. Performance of disposable endoscopic forceps according to the manufacturing techniques.

    PubMed

    Kwon, Chang-Il; Kim, Gwangil; Moon, Jong Pil; Yun, Ho; Ko, Weon Jin; Cho, Joo Young; Hong, Sung Pyo

    2018-03-05

    Recently, to lower the production costs and risk of infection, new disposable biopsy forceps made using simple manufacturing techniques have been introduced. However, the effects of the manufacturing techniques are unclear. The aim of this study was to evaluate which types of biopsy forceps could obtain good-quality specimens according to the manufacturing techniques. By using an in vitro nitrile glove popping model, we compared the popping ability among eight different disposable biopsy forceps (one pair of biopsy forceps with cups made by a cutting method [cutting forceps], four pairs of biopsy forceps with cups made by a pressing method [pressing forceps], and three pairs of biopsy forceps with cups made using a injection molding method [molding forceps]). Using an in vivo swine model, we compared the penetration depth and quality of specimen among the biopsy forceps. In the in vitro model, the molding forceps provided a significantly higher popping rate than the other forceps (cutting forceps, 25.0%; pressing forceps, 17.5%; and molding forceps, 41.7%; p = 0.006). In the in vivo model, the cutting and pressing forceps did not provide larger specimens, deeper biopsy specimen, and higher specimen adequacy than those obtained using the molding forceps (p = 0.2631, p = 0.5875, and p = 0.2147, respectively). However, the molding forceps showed significantly more common crush artifact than the others (cutting forceps, 0%; pressing forceps, 5.0%; and molding forceps, 43.3%; p = 0.0007). The molding forceps provided lower performance than the cutting and pressing forceps in terms of crush artifact.

  14. Nanoassembly of nanostructures by cutting, bending and soldering of carbon nanotubes with electron beam.

    PubMed

    Liu, Pou; Kantola, Kalle; Fukuda, Toshio; Arai, Fumihito

    2009-05-01

    We report that a series of in situ nanofabrication techniques of nanostructures, including cutting, bending and soldering of carbon nanotubes (CNTs), inside a field emission scanning electron microscope (FE-SEM) used for nanoassembly of nanostructures. The CNTs can be cut with electron beam assisted with oxygen gas. The cutting was developed for the bending of CNT, if some conditions of the cutting technique are changed. These include the increase of the acceleration voltage and/or setting the oxygen gas nozzle farther from the sample, and/or reducing the irradiation time. Using the proposed bending method angles larger than 90 degrees can be formed and the location of the kink can be set accurately. It is also shown that tungsten can be deposited on a substrate by the electron-beam-induced deposition, if the oxygen of the proposed cutting technique is replaced by W(CO)6. In this paper, these three nanofabrication methods were employed in the creation of a two dimensional (2D) nanostructure, the letters N and U, and a three dimensional (3D) nanostructure, the letter N. The 2D letters were constructed from 6 CNTs assembled on a substrate while the 3D letter N was bended from a single CNT and fixed to stand on a substrate. Based on the high performance of the proposed techniques, it is suggested that the cutting, bending, and soldering techniques inside SEM will become widely utilized in the fabrication and assembly of nanodevices and in the characterization of nanomaterials.

  15. Easy and Inexpensive Technique for Removal of Round Headed, Jammed Locking Screws in Distal Tibial Interlocking Plate.

    PubMed

    Singh, Harpreet; Sharma, Rohit; Gupta, Sachin; Singh, Narinderjit; Singh, Simarpreet

    2015-01-01

    The advent of locking plates has brought new problems in implant removal. Difficulty in removing screws from a locking plate is well-known. These difficulties include cold welding between the screw head and locking screw hole, stripping of the recess of the screw head for the screwdriver, and cross-threading between threads in the screw head and screw hole. However, there are cases in which removal is difficult. We describe a new technique for removing a round headed, jammed locking screws from a locking plate. 55 years old male patient received a locking distal tibial plate along with distal fibular plate 3years back from UAE. Now patient came with complaint of non-healing ulcer over medial aspect of lower 1/3rd of right leg from past 1 year. Non operative management did not improve the symptoms. The patient consented to implant removal, with the express understanding that implant removal might be impossible because already one failed attempt had been performed at some other hospital six months back. We then decided to proceed with the new technique. The rest of the proximal screws were removed using a technique not previously described. We used stainless steel metal cutting blades that are used to cut door locks or pad locks to cut the remaining stripped headed screws. This technique is very quick, easy to perform and inexpensive because the metal cutting blades which are used to cut the screws are very cheap. Yet it is very effective technique to remove the stripped headed or jammed locking screws. It is also very less destructive because of very less heat production during the procedure there is no problem of thermal necrosis to the bone or the surrounding soft tissue.

  16. Applications of optical sensing for laser cutting and drilling.

    PubMed

    Fox, Mahlen D T; French, Paul; Peters, Chris; Hand, Duncan P; Jones, Julian D C

    2002-08-20

    Any reliable automated production system must include process control and monitoring techniques. Two laser processing techniques potentially lending themselves to automation are percussion drilling and cutting. For drilling we investigate the performance of a modification of a nonintrusive optical focus control system we previously developed for laser welding, which exploits the chromatic aberrations of the processing optics to determine focal error. We further developed this focus control system for closed-loop control of laser cutting. We show that an extension of the technique can detect deterioration in cut quality, and we describe practical trials carried out on different materials using both oxygen and nitrogen assist gas. We base our techniques on monitoring the light generated by the process, captured nonintrusively by the effector optics and processed remotely from the workpiece. We describe the relationship between the temporal and the chromatic modulation of the detected light and process quality and show how the information can be used as the basis of a process control system.

  17. Additive lattice kirigami

    PubMed Central

    Castle, Toen; Sussman, Daniel M.; Tanis, Michael; Kamien, Randall D.

    2016-01-01

    Kirigami uses bending, folding, cutting, and pasting to create complex three-dimensional (3D) structures from a flat sheet. In the case of lattice kirigami, this cutting and rejoining introduces defects into an underlying 2D lattice in the form of points of nonzero Gaussian curvature. A set of simple rules was previously used to generate a wide variety of stepped structures; we now pare back these rules to their minimum. This allows us to describe a set of techniques that unify a wide variety of cut-and-paste actions under the rubric of lattice kirigami, including adding new material and rejoining material across arbitrary cuts in the sheet. We also explore the use of more complex lattices and the different structures that consequently arise. Regardless of the choice of lattice, creating complex structures may require multiple overlapping kirigami cuts, where subsequent cuts are not performed on a locally flat lattice. Our additive kirigami method describes such cuts, providing a simple methodology and a set of techniques to build a huge variety of complex 3D shapes. PMID:27679822

  18. Additive lattice kirigami.

    PubMed

    Castle, Toen; Sussman, Daniel M; Tanis, Michael; Kamien, Randall D

    2016-09-01

    Kirigami uses bending, folding, cutting, and pasting to create complex three-dimensional (3D) structures from a flat sheet. In the case of lattice kirigami, this cutting and rejoining introduces defects into an underlying 2D lattice in the form of points of nonzero Gaussian curvature. A set of simple rules was previously used to generate a wide variety of stepped structures; we now pare back these rules to their minimum. This allows us to describe a set of techniques that unify a wide variety of cut-and-paste actions under the rubric of lattice kirigami, including adding new material and rejoining material across arbitrary cuts in the sheet. We also explore the use of more complex lattices and the different structures that consequently arise. Regardless of the choice of lattice, creating complex structures may require multiple overlapping kirigami cuts, where subsequent cuts are not performed on a locally flat lattice. Our additive kirigami method describes such cuts, providing a simple methodology and a set of techniques to build a huge variety of complex 3D shapes.

  19. Performance of Ti-multilayer coated tool during machining of MDN431 alloyed steel

    NASA Astrophysics Data System (ADS)

    Badiger, Pradeep V.; Desai, Vijay; Ramesh, M. R.

    2018-04-01

    Turbine forgings and other components are required to be high resistance to corrosion and oxidation because which they are highly alloyed with Ni and Cr. Midhani manufactures one of such material MDN431. It's a hard-to-machine steel with high hardness and strength. PVD coated insert provide an answer to problem with its state of art technique on the WC tool. Machinability studies is carried out on MDN431 steel using uncoated and Ti-multilayer coated WC tool insert using Taguchi optimisation technique. During the present investigation, speed (398-625rpm), feed (0.093-0.175mm/rev), and depth of cut (0.2-0.4mm) varied according to Taguchi L9 orthogonal array, subsequently cutting forces and surface roughness (Ra) were measured. Optimizations of the obtained results are done using Taguchi technique for cutting forces and surface roughness. Using Taguchi technique linear fit model regression analysis carried out for the combination of each input variable. Experimented results are compared and found the developed model is adequate which supported by proof trials. Speed, feed and depth of cut are linearly dependent on the cutting force and surface roughness for uncoated insert whereas Speed and depth of cut feed is inversely dependent in coated insert for both cutting force and surface roughness. Machined surface for coated and uncoated inserts during machining of MDN431 is studied using optical profilometer.

  20. Multiple sclerosis lesion segmentation using an automatic multimodal graph cuts.

    PubMed

    García-Lorenzo, Daniel; Lecoeur, Jeremy; Arnold, Douglas L; Collins, D Louis; Barillot, Christian

    2009-01-01

    Graph Cuts have been shown as a powerful interactive segmentation technique in several medical domains. We propose to automate the Graph Cuts in order to automatically segment Multiple Sclerosis (MS) lesions in MRI. We replace the manual interaction with a robust EM-based approach in order to discriminate between MS lesions and the Normal Appearing Brain Tissues (NABT). Evaluation is performed in synthetic and real images showing good agreement between the automatic segmentation and the target segmentation. We compare our algorithm with the state of the art techniques and with several manual segmentations. An advantage of our algorithm over previously published ones is the possibility to semi-automatically improve the segmentation due to the Graph Cuts interactive feature.

  1. Short Lingual Osteotomy Using a Piezosurgery Ultrasonic Bone-Cutting Device During Sagittal Split Ramus Osteotomy.

    PubMed

    Kawase-Koga, Yoko; Mori, Yoshiyuki; Kanno, Yuki; Hoshi, Kazuto; Takato, Tsuyoshi

    2015-10-01

    Short lingual osteotomy is a useful method for the performance of sagittal split ramus osteotomy involving interference between the proximal and distal bone fragments when lateral differences exist in the setback distance. However, this procedure occasionally results in abnormal fracture and nerve injury; expert surgical skill is thus required. We herein describe a novel technique involving the use of an ultrasonic bone-cutting device (Piezosurgery; Mectron Medical Technology, Carasco, Italy) for vertical osteotomy posterior to the mandibular foramen. Successful short lingual osteotomy was performed using this technique with avoidance of abnormal fracture and neurovascular bundle damage.

  2. Dew point measurement technique utilizing fiber cut reflection

    NASA Astrophysics Data System (ADS)

    Kostritskii, S. M.; Dikevich, A. A.; Korkishko, Yu. N.; Fedorov, V. A.

    2009-05-01

    The fiber optical dew point hygrometer based on change of reflection coefficient for fiber cut has been developed and examined. We proposed and verified the model of condensation detector functioning principle. Experimental frost point measurements on air with different frost points have been performed.

  3. Characteristics and Machining Performance of TiN and TiAlN Coatings on a Milling Cutter

    NASA Astrophysics Data System (ADS)

    Sarwar, Mohammed; Haider, Julfikar

    2011-01-01

    Titanium Nitride (TiN) coating deposited by Physical Vapour Deposition (PVD) or Chemical Vapour Deposition (CVD) techniques on cutting tools (single point or multipoint) has contributed towards the improvement of tool life, productivity and product quality [1]. Addition of Al in TiN coating (e.g., TiAlN or AlTiN) has further improved the coating properties required for machining applications [2, 3]. This work presents a comparative investigation on TiN and TiAlN coatings deposited on to a Powder Metallurgy High Speed Steel (PM HSS) milling cutter used for machining bimetal (M42+D6A) steel strips. PVD (Arc evaporation) technique was used to deposit the coatings after carefully preparing the cutting edges of the milling cutter. Microstructure, chemical composition, hardness and adhesion of the coatings have been characterised using different techniques. The incorporation of Al into TiN coating results in an improvement in hardness, wear resistance and cutting performance. Examination of the worn flank in the coated cutting edges revealed that abrasive and adhesive wear are the predominant failure mechanisms. Tool designers, coating suppliers and manufacturing engineers could benefit from the information provided.

  4. Quartz crystal resonator g sensitivity measurement methods and recent results

    NASA Astrophysics Data System (ADS)

    Driscoll, M. M.

    1990-09-01

    A technique for accurate measurements of quartz crystal resonator vibration sensitivity is described. The technique utilizes a crystal oscillator circuit in which a prescribed length of coaxial cable is used to connect the resonator to the oscillator sustaining stage. A method is provided for determination and removal of measurement errors normally introduced as a result of cable vibration. In addition to oscillator-type measurements, it is also possible to perform similar vibration sensitivity measurements using a synthesized signal generator with the resonator installed in a passive phase bridge. Test results are reported for 40 and 50 MHz, fifth overtone AT-cut, and third overtone SC-cut crystals. Acceleration sensitivity (gamma vector) values for the SC-cut resonators were typically four times smaller (5 x 10 to the -10th/g) than for the AT-cut units. However, smaller unit-to-unit gamma vector magnitude variation was exhibited by the AT-cut resonators.

  5. Variability in the skin exposure of machine operators exposed to cutting fluids.

    PubMed

    Wassenius, O; Järvholm, B; Engström, T; Lillienberg, L; Meding, B

    1998-04-01

    This study describes a new technique for measuring skin exposure to cutting fluids and evaluates the variability of skin exposure among machine operators performing cyclic (repetitive) work. The technique is based on video recording and subsequent analysis of the video tape by means of computer-synchronized video equipment. The time intervals at which the machine operator's hand was exposed to fluid were registered, and the total wet time of the skin was calculated by assuming different evaporation times for the fluid. The exposure of 12 operators with different work methods was analyzed in 6 different workshops, which included a range of machine types, from highly automated metal cutting machines (ie, actual cutting and chip removal machines) requiring operator supervision to conventional metal cutting machines, where the operator was required to maneuver the machine and manually exchange products. The relative wet time varied between 0% and 100%. A significant association between short cycle time and high relative wet time was noted. However, there was no relationship between the degree of automatization of the metal cutting machines and wet time. The study shows that skin exposure to cutting fluids can vary considerably between machine operators involved in manufacturing processes using different types of metal cutting machines. The machine type was not associated with dermal wetness. The technique appears to give objective information about dermal wetness.

  6. Automatic Dissection Of Plantlets

    NASA Astrophysics Data System (ADS)

    Batchelor, B. G.; Harris, I. P.; Marchant, J. A.; Tillett, R. D.

    1989-03-01

    Micropropagation is a technique used in horticulture for generating a monoclonal colony of plants. A tiny plantlet is cut into several parts, each of which is then replanted. At the moment, the cutting is performed manually. Automating this task would have significant economic benefits. A robot designed to dissect plants would need to be equipped with intelligent visual sensing. This article is concerned with the image acquisition and processing techniques which such a machine might use. A program, which can calculate where to cut a plant with an "open" structure, is presented. This is expressed in the ProVision language, which is described in another article presented at this conference. (Article 1002-65)

  7. Pattern detection in forensic case data using graph theory: application to heroin cutting agents.

    PubMed

    Terrettaz-Zufferey, Anne-Laure; Ratle, Frédéric; Ribaux, Olivier; Esseiva, Pierre; Kanevski, Mikhail

    2007-04-11

    Pattern recognition techniques can be very useful in forensic sciences to point out to relevant sets of events and potentially encourage an intelligence-led style of policing. In this study, these techniques have been applied to categorical data corresponding to cutting agents found in heroin seizures. An application of graph theoretic methods has been performed, in order to highlight the possible relationships between the location of seizures and co-occurrences of particular heroin cutting agents. An analysis of the co-occurrences to establish several main combinations has been done. Results illustrate the practical potential of mathematical models in forensic data analysis.

  8. Thin edge-defined film-fed growth (EFG) octagons

    NASA Astrophysics Data System (ADS)

    Kalejs, J. P.

    1992-03-01

    Mobil Solar Energy Corp. investigated manufacturing crystalline silicon wafers using the edge-defined film-fed growth (EFG) technique. This report identifies the following: (1) current capabilities for manufacturing 200-micron-thick crystalline silicon wafers (10 cm x 10 cm) produced by growing octagons using the EFG technique and laser cutting them into wafers; (2) potential manufacturing improvements from decreasing the thickness of the wafers, improving the quality of the laser cut edge, and increasing cutting speed, all of which lead to reduce manufacturing costs, improved performance, and increased production capacities; (3) problems that impede achieving these potentials; and (4) costs and other requirements involved in overcoming the problems.

  9. Piezoelectric osteotomy in hand surgery: first experiences with a new technique

    PubMed Central

    Hoigne, Dominik J; Stübinger, Stefan; Kaenel, Oliver Von; Shamdasani, Sonia; Hasenboehler, Paula

    2006-01-01

    Background In hand and spinal surgery nerve lesions are feared complications with the use of standard oscillating saws. Oral surgeons have started using a newly developed ultrasound bone scalpel when performing precise osteotomies. By using a frequency of 25–29 kHz only mineralized tissue is cut, sparing the soft tissue. This reduces the risk of nerve lesions. As there is a lack of experience with this technique in the field of orthopaedic bone surgery, we performed the first ultrasound osteotomy in hand surgery. Method While performing a correctional osteotomy of the 5th metacarpal bone we used the Piezosurgery® Device from Mectron [Italy] instead of the usual oscillating saw. We will report on our experience with one case, with a follow up time of one year. Results The cut was highly precise and there were no vibrations of the bone. The time needed for the operation was slightly longer than the time needed while using the usual saw. Bone healing was good and at no point were there any neurovascular disturbances. Conclusion The Piezosurgery® Device is useful for small long bone osteotomies. Using the fine tip enables curved cutting and provides an opportunity for new osteotomy techniques. As the device selectively cuts bone we feel that this device has great potential in the field of hand- and spinal surgery. PMID:16611362

  10. CAD/CAM machining Vs pre-sintering in-lab fabrication techniques of Y-TZP ceramic specimens: Effects on their mechanical fatigue behavior.

    PubMed

    Zucuni, C P; Guilardi, L F; Fraga, S; May, L G; Pereira, G K R; Valandro, L F

    2017-07-01

    This study evaluated the effects of different pre-sintering fabrication processing techniques of Y-TZP ceramic (CAD/CAM Vs. in-lab), considering surface characteristics and mechanical performance outcomes. Pre-sintered discs of Y-TZP ceramic (IPS e.max ZirCAD, Ivoclar Vivadent) were produced using different pre-sintering fabrication processing techniques: Machined- milling with a CAD/CAM system; Polished- fabrication using a cutting device followed by polishing (600 and 1200 SiC papers); Xfine- fabrication using a cutting machine followed by grinding with extra-fine diamond bur (grit size 30 μm); Fine- fabrication using a cutting machine followed by grinding with fine diamond bur (grit size 46 μm); SiC- fabrication using a cutting machine followed by grinding with 220 SiC paper. Afterwards, the discs were sintered and submitted to roughness (n=35), surface topography (n=2), phase transformation (n=2), biaxial flexural strength (n=20), and biaxial flexural fatigue strength (fatigue limit) (n=15) analyses. No monoclinic-phase content was observed in all processing techniques. It can be observed that obtaining a surface with similar characteristics to CAD/CAM milling is essential for the observation of similar mechanical performance. On this sense, grinding with fine diamond bur before sintering (Fine group) was the best mimic protocol in comparison to the CAD/CAM milling. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Phacoemulsification using a chisel-shaped illuminator: enhanced depth trench, one-shot crack, and phaco cut.

    PubMed

    Wi, Jaemin; Seo, Hyejin; Lee, Jong Yeon; Nam, Dong Heun

    2016-01-01

    To evaluate the efficacy and outcomes of intracameral illuminator-assisted nucleofractis technique in cataract surgery. Since June 2012, this novel technique has been performed in all cataract cases by one surgeon (approximately 300 cases of various densities). Trenching continues until the posterior plate white reflex between an endonucleus and an epinucleus is identified (enhanced depth trench). After trenching, cracking is initiated with minimal separation force, and completion of cracking is confirmed by posterior capsule reflex (one-shot crack). With followability enhanced by an elliptical phaco mode, the divided nucleus is efficiently cut into small fragments by a chisel-shaped illuminator (phaco cut). We have not experienced any capsular bag or zonular complications, and the effective phacoemulsification time seemed to be shorter than that with the conventional technique. This technique simplifies the complete division of the nucleus, which is the most challenging step in safe and efficient phacoemulsification.

  12. Evaluation of the performance during hard turning of OHNS steel with minimal cutting fluid application and its comparison with minimum quantity lubrication

    NASA Astrophysics Data System (ADS)

    Raj, Anil; Wins, K. Leo Dev; Varadarajan, A. S.

    2016-09-01

    Cutting fluid application plays a significant role in the manufacturing industries that acts as a coolant as well as a lubricant. The conventional flood cooling application of cutting fluids not only increases the production cost on account of the expenses involved in procurement, storage and disposal but also creates serious environmental and health hazards. In order to overcome these negative effects, techniques like Minimum quantity lubrication (MQL) and Minimal Cutting fluid application (MCFA) have increasingly found their way into the area of metal cutting and have already been established as an alternative to conventional wet machining. This paper investigates the effect of minimal Cutting fluid application (MCFA) which involves application of high velocity pulsing jet of proprietary cutting fluids at the contact zones using a special fluid application system. During hard turning of oil hardened non shrinkable steel (OHNS) on cutting temperature and tool wear and to compare the performance with Minimum quantity lubrication (MQL) assisted hard turning in which cutting fluid is carried in a high velocity stream of air. An attempt was also made to compare the performance during Turning with MCFA and MQL application with conventional wet and dry turning by analysing the tool wear pattern using SEM images.

  13. High pressure water jet cutting and stripping

    NASA Technical Reports Server (NTRS)

    Hoppe, David T.; Babai, Majid K.

    1991-01-01

    High pressure water cutting techniques have a wide range of applications to the American space effort. Hydroblasting techniques are commonly used during the refurbishment of the reusable solid rocket motors. The process can be controlled to strip a thermal protective ablator without incurring any damage to the painted surface underneath by using a variation of possible parameters. Hydroblasting is a technique which is easily automated. Automation removes personnel from the hostile environment of the high pressure water. Computer controlled robots can perform the same task in a fraction of the time that would be required by manual operation.

  14. An evaluation of alternative reactor vessel cutting technologies for the experimental boiling water reactor at Argonne National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boing, L.E.; Henley, D.R.; Manion, W.J.

    1989-12-01

    Metal cutting techniques that can be used to segment the reactor pressure vessel of the Experimental Boiling Water Reactor (EBWR) at Argonne National Laboratory (ANL) have been evaluated by Nuclear Energy Services. Twelve cutting technologies are described in terms of their ability to perform the required task, their performance characteristics, environmental and radiological impacts, and cost and schedule considerations. Specific recommendations regarding which technology should ultimately be used by ANL are included. The selection of a cutting method was the responsibility of the decommissioning staff at ANL, who included a relative weighting of the parameters described in this document inmore » their evaluation process. 73 refs., 26 figs., 69 tabs.« less

  15. Finite element modelling of radial lentotomy cuts to improve the accommodation performance of the human lens.

    PubMed

    Burd, H J; Wilde, G S

    2016-04-01

    The use of a femtosecond laser to form planes of cavitation bubbles within the ocular lens has been proposed as a potential treatment for presbyopia. The intended purpose of these planes of cavitation bubbles (referred to in this paper as 'cutting planes') is to increase the compliance of the lens, with a consequential increase in the amplitude of accommodation. The current paper describes a computational modelling study, based on three-dimensional finite element analysis, to investigate the relationship between the geometric arrangement of the cutting planes and the resulting improvement in lens accommodation performance. The study is limited to radial cutting planes. The effectiveness of a variety of cutting plane geometries was investigated by means of modelling studies conducted on a 45-year human lens. The results obtained from the analyses depend on the particular modelling procedures that are employed. When the lens substance is modelled as an incompressible material, radial cutting planes are found to be ineffective. However, when a poroelastic model is employed for the lens substance, radial cuts are shown to cause an increase in the computed accommodation performance of the lens. In this case, radial cuts made in the peripheral regions of the lens have a relatively small influence on the accommodation performance of the lens; the lentotomy process is seen to be more effective when cuts are made near to the polar axis. When the lens substance is modelled as a poroelastic material, the computational results suggest that useful improvements in lens accommodation performance can be achieved, provided that the radial cuts are extended to the polar axis. Radial cuts are ineffective when the lens substance is modelled as an incompressible material. Significant challenges remain in developing a safe and effective surgical procedure based on this lentotomy technique.

  16. Gearbox Tooth Cut Fault Diagnostics Using Acoustic Emission and Vibration Sensors — A Comparative Study

    PubMed Central

    Qu, Yongzhi; He, David; Yoon, Jae; Van Hecke, Brandon; Bechhoefer, Eric; Zhu, Junda

    2014-01-01

    In recent years, acoustic emission (AE) sensors and AE-based techniques have been developed and tested for gearbox fault diagnosis. In general, AE-based techniques require much higher sampling rates than vibration analysis-based techniques for gearbox fault diagnosis. Therefore, it is questionable whether an AE-based technique would give a better or at least the same performance as the vibration analysis-based techniques using the same sampling rate. To answer the question, this paper presents a comparative study for gearbox tooth damage level diagnostics using AE and vibration measurements, the first known attempt to compare the gearbox fault diagnostic performance of AE- and vibration analysis-based approaches using the same sampling rate. Partial tooth cut faults are seeded in a gearbox test rig and experimentally tested in a laboratory. Results have shown that the AE-based approach has the potential to differentiate gear tooth damage levels in comparison with the vibration-based approach. While vibration signals are easily affected by mechanical resonance, the AE signals show more stable performance. PMID:24424467

  17. Silver ion chromatography for peak resolution enhancement: Application to the preparative separation of two sesquiterpenes using online heart-cutting LC-LC technique.

    PubMed

    Yang, Yang; Zhang, Yongmin; Wei, Chong; Li, Jing; Sun, Wenji

    2018-09-01

    Silver ion chromatography, utilizing columns packed with silver ions bonded to silica gel, has proved to be an invaluable technique for the analysis of some positional isomers. In this work, silver ion chromatography by combination with online heart-cutting LC-LC technique for the preparative separation of two sesquiterpenes positional isomers from a natural product was investigated. On the basis of the evaluation that silver ion content impacts on the separation, the laboratory-made silver ion columns, utilizing silica gel impregnated with 15% silver nitrate as column packing materials, were used for peak resolution improvement of these two isomers and the preparative separation of them in heart-cutting LC-LC. The relationship among the maximal sample load, flow rate and peak resolution in the silver ion column were optimized, and the performance of the silver ion column was compared with conventional C 18 column and silica gel column. Based on the developed chromatographic conditions, online heart-cutting LC-LC chromatographic separation system in combination with a silica gel column and a silver ion column that was applied to preparative separation of these two isomers from a traditional Chinese medicine, Inula racemosa Hook.f., was established. The results showed that the online heart-cutting LC-LC technique by combination of a silica gel column and a silver ion column for the preparative separation of these two positional isomers from this natural plant was superior to the preparative separation performed on a single-column system with C 18 column or silica gel column. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Quartz crystal resonator g sensitivity measurement methods and recent results.

    PubMed

    Driscoll, M M

    1990-01-01

    A technique for accurate measurements of quartz crystal resonator vibration sensitivity is described. The technique utilizes a crystal oscillator circuit in which a prescribed length of coaxial cable is used to connect the resonator to the oscillator sustaining stage. A method is provided for determination and removal of measurement errors normally introduced as a result of cable vibration. In addition to oscillator-type measurements, it is also possible to perform similar vibration sensitivity measurements using a synthesized signal generator with the resonator installed in a passive phase bridge. Test results are reported for 40 and 50 MHz, fifth overtone AT-cut, and third overtone SC-cut crystals. Acceleration sensitivity (gamma vector) values for the SC-cut resonators were typically four times smaller (5x10(-10) per g) than for the AT-cut units. However, smaller unit-to-unit gamma vector magnitude variation was exhibited by the AT-cut resonators. Oscillator sustaining stage vibration sensitivity was characterized by an equivalent open-loop phase modulation of 10(-6) rad/g.

  19. Performance of nursing auxiliaries and technicians in managing piercing cutting material: a necessary study.

    PubMed

    Moura, Elaine Cristina Carvalho; Moreira, Maria de Fátima Santana; da Fonseca, Soraia Martins

    2009-01-01

    This study aimed to analyze the knowledge of nursing auxiliaries and technicians in handling and disposing of piercing-cutting material and describe their performance. This qualitative-descriptive research was carried out with three nursing auxiliaries and 12 technicians at a medium-size hospital, totaling 15 participants interviewed through a semi-structured script. Discourse was analyzed through the content analysis technique. Results appoint that, even though the participants have theoretical knowledge on the management of piercing-cutting material, they do not totally follow their knowledge, which exposes them to several biological risks, revealing reproductive knowledge and performance. Thus, we propose the implementation of continuing education programs based on constructivist methodological approach aiming at effective practices in the management and disposal of piercing-cutting material. In this perspective, research clarifying how adults apprehend knowledge can deepen the results described in the study.

  20. The use of piezosurgery in cranial surgery in children.

    PubMed

    Ramieri, Valerio; Saponaro, Gianmarco; Lenzi, Jacopo; Caporlingua, Federico; Polimeni, Antonella; Silvestri, Alessandro; Pizzuti, Antonio; Roggini, Mario; Tarani, Luigi; Papoff, Paola; Giancotti, Antonella; Castori, Marco; Manganaro, Lucia; Cascone, Piero; Piero, Cascone

    2015-05-01

    Piezosurgery is an alternative surgical technique, now widely tested, that uses ultrasounds for bone cutting. This device uses ultrasounds to section hard tissues without harming surrounding soft tissues. The authors analyzed their experience in craniomaxillofacial procedures with piezosurgery. A comparison between operation timing and complication rates between piezosurgery and traditional cutting instruments has been performed. A total of 27 patients were examined (15 females and 12 males; average age, of 5.5 months) affected by craniosynostosis. The aim of this study was to analyze the advantages and disadvantages of piezosurgery in pediatric craniofacial procedures. Piezoelectric device in this study has shown being a valid instrument for bone cutting in accurate procedures, because it allows performing a more precise and safer cutting, without the risk of harming surrounding tissues.

  1. Orthogonal cutting of cancellous bone with application to the harvesting of bone autograft.

    PubMed

    Malak, Sharif F F; Anderson, Iain A

    2008-07-01

    Autogenous bone graft harvesting results in cell death within the graft and trauma at the donor site. The latter can be mitigated by using minimally invasive tools and techniques, while cell morbidity may be reduced by improving cutter design and cutting parameters. We have performed orthogonal cutting experiments on bovine cancellous bone samples, to gain a basic understanding of the cutting mechanism and to determine design guidelines for tooling. Measurements were performed at cutting speeds from 11.2 to 5000 mm/min, with tool rake angles of 23 degrees, 45 degrees and 60 degrees, and depths of cut in the range of 0.1-3.0 mm. Horizontal and vertical cutting forces were measured, and the chip formation process video recorded. Continuous chip formation was observed for rake angles of 45 degrees and 60 degrees , and depths of cut greater than 0.8 mm. Chip formation for depths of cut greater than 1.0 mm was accompanied by bone marrow extruding out of the free surfaces and away from the rake face. Specific cutting energies decreased with increasing rake angle, increasing depth of cut and increasing cutting speed. Our orthogonal cutting experiments showed that a rake angle of 60 degrees and a depth of cut of 1mm, will avoid excessive fragmentation, keep specific cutting energy low and promote bone marrow extrusion, which may be beneficial for cell survival. We demonstrate how drill bit clearance angle and feed rate can be calculated facilitating a 1mm depth of cut.

  2. Optimization of Coolant Technique Conditions for Machining A319 Aluminium Alloy Using Response Surface Method (RSM)

    NASA Astrophysics Data System (ADS)

    Zainal Ariffin, S.; Razlan, A.; Ali, M. Mohd; Efendee, A. M.; Rahman, M. M.

    2018-03-01

    Background/Objectives: The paper discusses about the optimum cutting parameters with coolant techniques condition (1.0 mm nozzle orifice, wet and dry) to optimize surface roughness, temperature and tool wear in the machining process based on the selected setting parameters. The selected cutting parameters for this study were the cutting speed, feed rate, depth of cut and coolant techniques condition. Methods/Statistical Analysis Experiments were conducted and investigated based on Design of Experiment (DOE) with Response Surface Method. The research of the aggressive machining process on aluminum alloy (A319) for automotive applications is an effort to understand the machining concept, which widely used in a variety of manufacturing industries especially in the automotive industry. Findings: The results show that the dominant failure mode is the surface roughness, temperature and tool wear when using 1.0 mm nozzle orifice, increases during machining and also can be alternative minimize built up edge of the A319. The exploration for surface roughness, productivity and the optimization of cutting speed in the technical and commercial aspects of the manufacturing processes of A319 are discussed in automotive components industries for further work Applications/Improvements: The research result also beneficial in minimizing the costs incurred and improving productivity of manufacturing firms. According to the mathematical model and equations, generated by CCD based RSM, experiments were performed and cutting coolant condition technique using size nozzle can reduces tool wear, surface roughness and temperature was obtained. Results have been analyzed and optimization has been carried out for selecting cutting parameters, shows that the effectiveness and efficiency of the system can be identified and helps to solve potential problems.

  3. Into the development of a model to assess beam shaping and polarization control effects on laser cutting

    NASA Astrophysics Data System (ADS)

    Rodrigues, Gonçalo C.; Duflou, Joost R.

    2018-02-01

    This paper offers an in-depth look into beam shaping and polarization control as two of the most promising techniques for improving industrial laser cutting of metal sheets. An assessment model is developed for the study of such effects. It is built upon several modifications to models as available in literature in order to evaluate the potential of a wide range of considered concepts. This includes different kinds of beam shaping (achieved by extra-cavity optical elements or asymmetric diode staking) and polarization control techniques (linear, cross, radial, azimuthal). A fully mathematical description and solution procedure are provided. Three case studies for direct diode lasers follow, containing both experimental data and parametric studies. In the first case study, linear polarization is analyzed for any given angle between the cutting direction and the electrical field. In the second case several polarization strategies are compared for similar cut conditions, evaluating, for example, the minimum number of spatial divisions of a segmented polarized laser beam to achieve a target performance. A novel strategy, based on a 12-division linear-to-radial polarization converter with an axis misalignment and capable of improving cutting efficiency with more than 60%, is proposed. The last case study reveals different insights in beam shaping techniques, with an example of a beam shape optimization path for a 30% improvement in cutting efficiency. The proposed techniques are not limited to this type of laser source, neither is the model dedicated to these specific case studies. Limitations of the model and opportunities are further discussed.

  4. Grading technologies for the manufacture of innovative cutting blades

    NASA Astrophysics Data System (ADS)

    Rostek, Tim; Homberg, Werner

    2018-05-01

    Cutting blades for harvesting applications are used in a variety of agricultural machines. These parts are in contact with highly abrasive lawn clippings and often wear out within hours which results in high expensive re-sharpening maintenance. This paper relates to manufacturing techniques enhancing the durability of cutting blades based on a structural analysis of the prevailing wear mechanisms containing chipping and abrasive wear. Each mechanism results in specific demands on the cutting edge's mechanical characteristics. The design of evaluation methods respectively is one issue of the paper. This is basis for approaches to improve the cutting edge performance on purpose. On option to improve abrasive wear resistance and, thus, service life is the application of locally graded steel materials as semi-finished products for self-sharpening cutting blades. These materials comprise a layered structure consisting of a hard, wear resistant layer and a relatively softer layer which is lesser wear resistant. As the cutting blade is subjected to wear conditions, the less wear resistant layer wears faster than the relatively more wear resistant harder layer revealing a durable cross section of the cutting edge and, thus, cutting performance. Anyways, chipping is another key issue on the cutting edge's lifetime. Here, the cutting edges cross section by means of geometry and grind respectively as well as its mechanical properties matter. FEM analysis reveal innovative options to optimize the cross section of the blade as well as thermomechanical strengthening add further strength to reduce chipping. This paper contains a comprehensive strategy to improve cutting blades with use of innovative manufacturing technologies which apply application-specific graded mechanical characteristics and, thus, significantly improved performance characteristics.

  5. The Big-Bubble Full Femtosecond Laser-Assisted Technique in Deep Anterior Lamellar Keratoplasty.

    PubMed

    Buzzonetti, Luca; Petrocelli, Gianni; Valente, Paola; Iarossi, Giancarlo; Ardia, Roberta; Petroni, Sergio; Parrilla, Rosa

    2015-12-01

    To describe the big-bubble full femtosecond laser-assisted (BBFF) technique, which could be helpful in standardizing the big-bubble technique in deep anterior lamellar keratoplasty (DALK). Ten eyes of 10 consecutive patients affected by keratoconus underwent the BBFF technique using the 150-kHz IntraLase femtosecond laser (Intra-Lase FS Laser; Abbott Medical Optics, Inc., Santa Ana, CA). A 9-mm diameter metal mask with a single fissure 0.7 mm wide oriented at the 12-o'clock position was positioned into the cone, over the laser glass. The laser performed a ring lamellar cut (internal diameter = 3 mm; external diameter = 8 mm) 100 µm above the thinnest point, with the photodisruption effectively occurring only in the corneal stroma corresponding to the fissure to create a deep stromal channel; subsequently, an anterior side cut created an arcuate incision, from the corneal surface to the deep stromal channel on the mask's opening site. The mask was removed and the laser performed a full lamellar cut 200 µm above the thinnest point to create a lamella. After the removal of the lamella, the air needle was inserted into the stromal channel and air was injected to achieve a big bubble. The big bubble was achieved in 9 eyes (all type 1 bubbles) and all procedures were completed as DALK. Preliminary results suggest that the BBFF technique could help in standardizing the big-bubble technique in DALK, reducing the "learning curve" for surgeons who approach this technique and the risks of intraoperative complications. Copyright 2015, SLACK Incorporated.

  6. Biomechanical factors associated with time to complete a change of direction cutting maneuver.

    PubMed

    Marshall, Brendan M; Franklyn-Miller, Andrew D; King, Enda A; Moran, Kieran A; Strike, Siobhán C; Falvey, Éanna C

    2014-10-01

    Cutting ability is an important aspect of many team sports, however, the biomechanical determinants of cutting performance are not well understood. This study aimed to address this issue by identifying the kinetic and kinematic factors correlated with the time to complete a cutting maneuver. In addition, an analysis of the test-retest reliability of all biomechanical measures was performed. Fifteen (n = 15) elite multidirectional sports players (Gaelic hurling) were recruited, and a 3-dimensional motion capture analysis of a 75° cut was undertaken. The factors associated with cutting time were determined using bivariate Pearson's correlations. Intraclass correlation coefficients (ICCs) were used to examine the test-retest reliability of biomechanical measures. Five biomechanical factors were associated with cutting time (2.28 ± 0.11 seconds): peak ankle power (r = 0.77), peak ankle plantar flexor moment (r = 0.65), range of pelvis lateral tilt (r = -0.54), maximum thorax lateral rotation angle (r = 0.51), and total ground contact time (r = -0.48). Intraclass correlation coefficient scores for these 5 factors, and indeed for the majority of the other biomechanical measures, ranged from good to excellent (ICC >0.60). Explosive force production about the ankle, pelvic control during single-limb support, and torso rotation toward the desired direction of travel were all key factors associated with cutting time. These findings should assist in the development of more effective training programs aimed at improving similar cutting performances. In addition, test-retest reliability scores were generally strong, therefore, motion capture techniques seem well placed to further investigate the determinants of cutting ability.

  7. Debris-free rear-side picosecond laser ablation of thin germanium wafers in water with ethanol

    NASA Astrophysics Data System (ADS)

    Zhang, Dongshi; Gökce, Bilal; Sommer, Steffen; Streubel, René; Barcikowski, Stephan

    2016-03-01

    In this paper, we perform liquid-assisted picosecond laser cutting of 150 μm thin germanium wafers from the rear side. By investigating the cutting efficiency (the ability to allow an one-line cut-through) and quality (characterized by groove morphologies on both sides), the pros and cons of this technique under different conditions are clarified. Specifically, with laser fluence fixed, repetition rate and scanning speed are varied to show quality and efficiency control by means of laser parameter modulation. It is found that low repetition rate ablation in liquid gives rise to a better cut quality on the front side than high repetition rate ablation since it avoids dispersed nanoparticles redeposition resulting from a bubble collapse, unlike the case of 100 kHz which leads to large nanorings near the grooves resulting from a strong interaction of bubbles and the case of 50 kHz which leads to random cutting due to the interaction of the former pulse induced cavitation bubble and the subsequent laser pulse. Furthermore, ethanol is mixed with pure distilled water to assess the liquid's impact on the cutting efficiency and cutting quality. The results show that increasing the ethanol fraction decreases the ablation efficiency but simultaneously, greatly improves the cutting quality. The improvement of cut quality as ethanol ratio increases may be attributed to less laser beam interference by a lower density of bubbles which adhere near the cut kerf during ablation. A higher density of bubbles generated from ethanol vaporization during laser ablation in liquid will cause stronger bubble shielding effect toward the laser beam propagation and therefore result in less laser energy available for the cut, which is the main reason for the decrease of cut efficiency in water-ethanol mixtures. Our findings give an insight into under which condition the rear-side laser cutting of thin solar cells should be performed: high repetition, pure distilled water and high laser power are favorable for high-speed rough cutting but the cut kerf suffers from strong side effects of ripples, nanoredeposition occurrence, while low laser power at low repetition rate (10 kHz), mixed solution (1 wt% ethanol in water) and moderate scanning speed (100 μm/s) are preferable for ultrafine high-quality debris-free cutting. The feasibility of high-quality cut is a good indication of using rear laser ablation in liquid to cut thinner wafers. More importantly, this technique spares any post cleaning steps to reduce the risk to the contamination or crack of the thin wafers.

  8. Nanofluid as coolant for grinding process: An overview

    NASA Astrophysics Data System (ADS)

    Kananathan, J.; Samykano, M.; Sudhakar, K.; Subramaniam, S. R.; Selavamani, S. K.; Manoj Kumar, Nallapaneni; Keng, Ngui Wai; Kadirgama, K.; Hamzah, W. A. W.; Harun, W. S. W.

    2018-04-01

    This paper reviews the recent progress and applications of nanoparticles in lubricants as a coolant (cutting fluid) for grinding process. The role of grinding machining in manufacturing and the importance of lubrication fluids during material removal are discussed. In grinding process, coolants are used to improve the surface finish, wheel wear, flush the chips and to reduce the work-piece thermal deformation. The conventional cooling technique, i.e., flood cooling delivers a large amount of fluid and mist which hazardous to the environment and humans. Industries are actively looking for possible ways to reduce the volume of coolants used in metal removing operations due to the economical and ecological impacts. Thus as an alternative, an advanced cooling technique known as Minimum Quantity Lubrication (MQL) has been introduced to the enhance the surface finish, minimize the cost, to reduce the environmental impacts and to reduce the metal cutting fluid consumptions. Nanofluid is a new-fangled class of fluids engineered by dispersing nanometre-size solid particles into base fluids such as water, lubrication oils to further improve the properties of the lubricant or coolant. In addition to advanced cooling technique review, this paper also reviews the application of various nanoparticles and their performance in grinding operations. The performance of nanoparticles related to the cutting forces, surface finish, tool wear, and temperature at the cutting zone are briefly reviewed. The study reveals that the excellent properties of the nanofluid can be beneficial in cooling and lubricating application in the manufacturing process.

  9. Ceramic tools insert assesment based on vickers indentation methodology

    NASA Astrophysics Data System (ADS)

    Husni; Rizal, Muhammad; Aziz M, M.; Wahyu, M.

    2018-05-01

    In the interrupted cutting process, the risk of tool chipping or fracture is higher than continues cutting. Therefore, the selection of suitable ceramic tools for interrupted cutting application become an important issue to assure that the cutting process is running effectively. At present, the performance of ceramics tools is assessed by conducting some cutting tests, which is required time and cost consuming. In this study, the performance of ceramic tools evaluated using hardness tester machine. The technique, in general, has a certain advantage compare with the more conventional methods; the experimental is straightforward involving minimal specimen preparation and the amount of material needed is small. Three types of ceramic tools AS10, CC650 and K090 have been used, each tool was polished then Vickers indentation test were performed with the load were 0.2, 0.5, 1, 2.5, 5 and 10 kgf. The results revealed that among the load used in the tests, the indentation loads of 5 kgf always produce well cracks as compared with others. Among the cutting tool used in the tests, AS10 has produced the shortest crack length and follow by CC 670, and K090. It is indicated that the shortest crack length of AS10 reflected that the tool has a highest dynamic load resistance among others insert.

  10. Effort, symptom validity testing, performance validity testing and traumatic brain injury.

    PubMed

    Bigler, Erin D

    2014-01-01

    To understand the neurocognitive effects of brain injury, valid neuropsychological test findings are paramount. This review examines the research on what has been referred to a symptom validity testing (SVT). Above a designated cut-score signifies a 'passing' SVT performance which is likely the best indicator of valid neuropsychological test findings. Likewise, substantially below cut-point performance that nears chance or is at chance signifies invalid test performance. Significantly below chance is the sine qua non neuropsychological indicator for malingering. However, the interpretative problems with SVT performance below the cut-point yet far above chance are substantial, as pointed out in this review. This intermediate, border-zone performance on SVT measures is where substantial interpretative challenges exist. Case studies are used to highlight the many areas where additional research is needed. Historical perspectives are reviewed along with the neurobiology of effort. Reasons why performance validity testing (PVT) may be better than the SVT term are reviewed. Advances in neuroimaging techniques may be key in better understanding the meaning of border zone SVT failure. The review demonstrates the problems with rigidity in interpretation with established cut-scores. A better understanding of how certain types of neurological, neuropsychiatric and/or even test conditions may affect SVT performance is needed.

  11. A modified technique to reduce tibial keel cutting errors during an Oxford unicompartmental knee arthroplasty.

    PubMed

    Inui, Hiroshi; Taketomi, Shuji; Tahara, Keitarou; Yamagami, Ryota; Sanada, Takaki; Tanaka, Sakae

    2017-03-01

    Bone cutting errors can cause malalignment of unicompartmental knee arthroplasties (UKA). Although the extent of tibial malalignment due to horizontal cutting errors has been well reported, there is a lack of studies evaluating malalignment as a consequence of keel cutting errors, particularly in the Oxford UKA. The purpose of this study was to examine keel cutting errors during Oxford UKA placement using a navigation system and to clarify whether two different tibial keel cutting techniques would have different error rates. The alignment of the tibial cut surface after a horizontal osteotomy and the surface of the tibial trial component was measured with a navigation system. Cutting error was defined as the angular difference between these measurements. The following two techniques were used: the standard "pushing" technique in 83 patients (group P) and a modified "dolphin" technique in 41 patients (group D). In all 123 patients studied, the mean absolute keel cutting error was 1.7° and 1.4° in the coronal and sagittal planes, respectively. In group P, there were 22 outlier patients (27 %) in the coronal plane and 13 (16 %) in the sagittal plane. Group D had three outlier patients (8 %) in the coronal plane and none (0 %) in the sagittal plane. Significant differences were observed in the outlier ratio of these techniques in both the sagittal (P = 0.014) and coronal (P = 0.008) planes. Our study demonstrated overall keel cutting errors of 1.7° in the coronal plane and 1.4° in the sagittal plane. The "dolphin" technique was found to significantly reduce keel cutting errors on the tibial side. This technique will be useful for accurate component positioning and therefore improve the longevity of Oxford UKAs. Retrospective comparative study, Level III.

  12. The effects of 2 landing techniques on knee kinematics, kinetics, and performance during stop-jump and side-cutting tasks.

    PubMed

    Dai, Boyi; Garrett, William E; Gross, Michael T; Padua, Darin A; Queen, Robin M; Yu, Bing

    2015-02-01

    Anterior cruciate ligament injuries (ACL) commonly occur during jump landing and cutting tasks. Attempts to land softly and land with greater knee flexion are associated with decreased ACL loading. However, their effects on performance are unclear. Attempts to land softly will decrease peak posterior ground-reaction force (PPGRF) and knee extension moment at PPGRF compared with a natural landing during stop-jump and side-cutting tasks. Attempts to land with greater knee flexion at initial ground contact will increase knee flexion at PPGRF compared with a natural landing during both tasks. In addition, both landing techniques will increase stance time and lower extremity mechanical work as well as decrease jump height and movement speed compared with a natural landing during both tasks. Controlled laboratory study. A total of 18 male and 18 female recreational athletes participated in the study. Three-dimensional kinematic and kinetic data were collected during stop-jump and side-cutting tasks under 3 conditions: natural landing, soft landing, and landing with greater knee flexion at initial ground contact. Attempts to land softly decreased PPGRF and knee extension moment at PPGRF compared with a natural landing during stop-jump tasks. Attempts to land softly decreased PPGRF compared with a natural landing during side-cutting tasks. Attempts to land with greater knee flexion at initial ground contact increased knee flexion angle at PPGRF compared with a natural landing during both stop-jump and side-cutting tasks. Attempts to land softly and land with greater knee flexion at initial ground contact increased stance time and lower extremity mechanical work, as well as decreased jump height and movement speed during both stop-jump and side-cutting tasks. Although landing softly and landing with greater knee flexion at initial ground contact may reduce ACL loading during stop-jump and side-cutting tasks, the performance of these tasks decreased, as indicated by increased stance time and mechanical work as well as decreased jump height and movement speed. Training effects tested in laboratory environments with the focus on reducing ACL loading may be reduced in actual competition environments when the focus is on athlete performance. The effects of training programs for ACL injury prevention on lower extremity biomechanics in athletic tasks may need to be evaluated in laboratories as well as in actual competitions. © 2014 The Author(s).

  13. Augmentation of the Nasal Dorsum Using the Multistrip Autologous Cartilage Technique.

    PubMed

    Liu, Liqiang; Bu, Zhaoyun; Fan, Jincai; Tian, Jia; Gan, Cheng; Yang, Zengjie; Jiao, Hu

    2017-12-01

    Nasal augmentation is a popular modern technique requested by many Asian people. There are two kinds of autologous cartilage used to augment the nose at present: carved as a monobloc or diced into pieces. Each approach has its pros and cons. The authors performed their surgical technique on a group of 28 patients. Twenty of these patients had undergone rhinoplasties performed before referral to our hospital; eight of these patients had undergone a primary rhinoplasty. Bilateral conchal, nasal septum, or rib cartilage was harvested; deep temporal fascia or abdominal muscle fascia to be prepared for packing stripped cartilage was also removed at this time. The cartilage was placed on a plastic cutting board and cut into strips with a transverse section of 1 × 1 mm. Then, these strips were packed and covered by fascia to form the grafts. The median follow-up was 23 months (range, 12 to 48 months). Twenty-two patients were satisfied with their augmented noses. Through examinations, biopsies, and magnetic resonance imaging scans, less resorption was observed with the multistrip autologous cartilage technique. Junctional stepoffs, excessive prominence, and slanting grafts occurred in three patients, two of whom had revisions. Using multistrip autologous cartilage grafts is an easier method to perform and could be another alternative technique for augmentative and reconstructive rhinoplasties.

  14. Stretchable Kirigami Polyvinylidene Difluoride Thin Films for Energy Harvesting: Design, Analysis, and Performance

    NASA Astrophysics Data System (ADS)

    Hu, Nan; Chen, Dajing; Wang, Dong; Huang, Shicheng; Trase, Ian; Grover, Hannah M.; Yu, Xiaojiao; Zhang, John X. J.; Chen, Zi

    2018-02-01

    Kirigami, a modified form of origami which includes cutting, has been used to improve material stretchability and compliance. However, this technique is, so far, underexplored in patterning piezoelectric materials towards developing efficient and mechanically flexible thin-film energy generators. Motivated by existing kirigami-based applications, we introduce interdigitated cuts to polyvinylidene fluoride (PVDF) films to evaluate the effect on voltage generation and stretchability. Our results from theoretical analysis, numerical simulations, and experimental tests show that kirigami PVDF films exhibit an extended strain range while still maintaining significant voltage generation compared to films without cuts. Various cutting patterns are studied, and it is found that films with denser cuts have a larger voltage output. This kirigami design can enhance the properties of existing piezoelectric materials and help to integrate tunable PVDF generators into biomedical devices.

  15. Long gap esophageal atresia: lengthening technique and primary anastomosis.

    PubMed

    Hadidi, Ahmed T; Hosie, Stuart; Waag, Karl-Ludwig

    2007-10-01

    The treatment of long gap esophageal atresia remains a major surgical challenge. The authors describe a modification of a lengthening technique based on tissue expansion to avoid sutures cutting through the esophagus. Between January 2004 and August 2006, 4 patients did not respond to stretching, and underwent this modified esophageal lengthening technique using silastic tubes. RESULTS AND FOLLOW-UP: All infants recovered and have an intact esophagus. All infants developed gastroesophageal reflux. Thal antireflux procedure was performed in the first infant. The other 3 patients were managed conservatively. Follow-up ranged between 6 and 34 months. The tissue expansion principle can be successfully applied in the esophagus through external traction. Silastic tube fixation at esophageal ends may help to apply even traction and avoid sutures cutting through the esophageal tissue.

  16. Use of prototype two-channel endoscope with elevator enables larger lift-and-snare endoscopic mucosal resection in a porcine model

    PubMed Central

    Atkinson, Matthew; Chukwumah, Chike; Marks, Jeffrey; Chak, Amitabh

    2014-01-01

    Background: Flat and depressed lesions are becoming increasingly recognized in the esophagus, stomach, and colon. Various techniques have been described for endoscopic mucosal resection (EMR) of these lesions. Aims: To evaluate the efficacy of lift-grasp-cut EMR using a prototype dual-channel forward-viewing endoscope with an instrument elevator in one accessory channel (dual-channel elevator scope) as compared to standard dual-channel endoscopes. Methods: EMR was performed using a lift-grasp-cut technique on normal flat rectosigmoid or gastric mucosa in live porcine models after submucosal injection of 4 mL of saline using a dual-channel elevator scope or a standard dual-channel endoscope. With the dual-channel elevator scope, the elevator was used to attain further lifting of the mucosa. The primary endpoint was size of the EMR specimen and the secondary endpoint was number of complications. Results: Twelve experiments were performed (six gastric and six colonic). Mean specimen diameter was 2.27 cm with the dual-channel elevator scope and 1.34 cm with the dual-channel endoscope (P = 0.018). Two colonic perforations occurred with the dual-channel endoscope, vs no complications with the dual-channel elevator scope. Conclusions: The increased lift of the mucosal epithelium, through use of the dual-channel elevator scope, allows for larger EMR when using a lift-grasp-cut technique. Noting the thin nature of the porcine colonic wall, use of the elevator may also make this technique safer. PMID:24760237

  17. Modeling of tool path for the CNC sheet cutting machines

    NASA Astrophysics Data System (ADS)

    Petunin, Aleksandr A.

    2015-11-01

    In the paper the problem of tool path optimization for CNC (Computer Numerical Control) cutting machines is considered. The classification of the cutting techniques is offered. We also propose a new classification of toll path problems. The tasks of cost minimization and time minimization for standard cutting technique (Continuous Cutting Problem, CCP) and for one of non-standard cutting techniques (Segment Continuous Cutting Problem, SCCP) are formalized. We show that the optimization tasks can be interpreted as discrete optimization problem (generalized travel salesman problem with additional constraints, GTSP). Formalization of some constraints for these tasks is described. For the solution GTSP we offer to use mathematical model of Prof. Chentsov based on concept of a megalopolis and dynamic programming.

  18. Routine Chest X-ray: Still Valuable for the Assessment of Left Ventricular Size and Function in the Era of Super Machines?

    PubMed Central

    Morales, Maria-Aurora; Prediletto, Renato; Rossi, Giuseppe; Catapano, Giosuè; Lombardi, Massimo; Rovai, Daniele

    2012-01-01

    Objectives: The development of technologically advanced, expensive techniques has progressively reduced the value of chest X-ray in clinical practice for the assessment of left ventricular (LV) dilatation and dysfunction. Although controversial data are reported on the role of this widely available technique in cardiac assessment, it is known that the cardio-thoracic ratio is predictive of risk of progression in the NYHA Class, hospitalization, and outcome in patients with LV dysfunction. This study aimed to evaluate the reliability of the transverse diameter of heart shadow [TDH] by chest X-ray for detecting LV dilatation and dysfunction as compared to Magnetic Resonance Imaging (MRI) performed for different clinical reasons. Materials and Methods: In 101 patients, TDH was measured in digital chest X-ray and LV volumes and ejection fraction (EF) by MRI, both exams performed within 2 days. Results: A direct correlation between TDH and end-diastolic volumes (r = .75, P<0.0001) was reported. TDH cut-off values of 14.5 mm in females identified LV end-diastolic volumes >150 mL (sensitivity: 82%, specificity: 69%); in males a cut-off value of 15.5 mm identified LV end-diastolic volumes >210 mL (sensitivity: 84%; specificity: 72%). A negative relation was found between TDH and LVEF (r = -.54, P<0.0001). The above cut-off values of TDH discriminated patients with LV systolic dysfunction – LVEF <35% (sensitivity and specificity: 67% and 57% in females; 76% and 59% in males, respectively). Conclusions: Chest X-ray may still be considered a reliable technique in predicting LV dilatation by the accurate measurement of TDH as compared to cardiac MRI. Technologically advanced, expensive, and less available imaging techniques should be performed on the basis of sound clinical requests. PMID:22754739

  19. Routine Chest X-ray: Still Valuable for the Assessment of Left Ventricular Size and Function in the Era of Super Machines?

    PubMed

    Morales, Maria-Aurora; Prediletto, Renato; Rossi, Giuseppe; Catapano, Giosuè; Lombardi, Massimo; Rovai, Daniele

    2012-01-01

    The development of technologically advanced, expensive techniques has progressively reduced the value of chest X-ray in clinical practice for the assessment of left ventricular (LV) dilatation and dysfunction. Although controversial data are reported on the role of this widely available technique in cardiac assessment, it is known that the cardio-thoracic ratio is predictive of risk of progression in the NYHA Class, hospitalization, and outcome in patients with LV dysfunction. This study aimed to evaluate the reliability of the transverse diameter of heart shadow [TDH] by chest X-ray for detecting LV dilatation and dysfunction as compared to Magnetic Resonance Imaging (MRI) performed for different clinical reasons. In 101 patients, TDH was measured in digital chest X-ray and LV volumes and ejection fraction (EF) by MRI, both exams performed within 2 days. A direct correlation between TDH and end-diastolic volumes (r = .75, P<0.0001) was reported. TDH cut-off values of 14.5 mm in females identified LV end-diastolic volumes >150 mL (sensitivity: 82%, specificity: 69%); in males a cut-off value of 15.5 mm identified LV end-diastolic volumes >210 mL (sensitivity: 84%; specificity: 72%). A negative relation was found between TDH and LVEF (r = -.54, P<0.0001). The above cut-off values of TDH discriminated patients with LV systolic dysfunction - LVEF <35% (sensitivity and specificity: 67% and 57% in females; 76% and 59% in males, respectively). Chest X-ray may still be considered a reliable technique in predicting LV dilatation by the accurate measurement of TDH as compared to cardiac MRI. Technologically advanced, expensive, and less available imaging techniques should be performed on the basis of sound clinical requests.

  20. Hairy Slices: Evaluating the Perceptual Effectiveness of Cutting Plane Glyphs for 3D Vector Fields.

    PubMed

    Stevens, Andrew H; Butkiewicz, Thomas; Ware, Colin

    2017-01-01

    Three-dimensional vector fields are common datasets throughout the sciences. Visualizing these fields is inherently difficult due to issues such as visual clutter and self-occlusion. Cutting planes are often used to overcome these issues by presenting more manageable slices of data. The existing literature provides many techniques for visualizing the flow through these cutting planes; however, there is a lack of empirical studies focused on the underlying perceptual cues that make popular techniques successful. This paper presents a quantitative human factors study that evaluates static monoscopic depth and orientation cues in the context of cutting plane glyph designs for exploring and analyzing 3D flow fields. The goal of the study was to ascertain the relative effectiveness of various techniques for portraying the direction of flow through a cutting plane at a given point, and to identify the visual cues and combinations of cues involved, and how they contribute to accurate performance. It was found that increasing the dimensionality of line-based glyphs into tubular structures enhances their ability to convey orientation through shading, and that increasing their diameter intensifies this effect. These tube-based glyphs were also less sensitive to visual clutter issues at higher densities. Adding shadows to lines was also found to increase perception of flow direction. Implications of the experimental results are discussed and extrapolated into a number of guidelines for designing more perceptually effective glyphs for 3D vector field visualizations.

  1. Religious slaughter: evaluation of current practices in selected countries.

    PubMed

    Velarde, A; Rodriguez, P; Dalmau, A; Fuentes, C; Llonch, P; von Holleben, K V; Anil, M H; Lambooij, J B; Pleiter, H; Yesildere, T; Cenci-Goga, B T

    2014-01-01

    As part of the project "Religious slaughter (DIALREL): improving knowledge and expertise through dialogue and debate on issues of welfare, legislation and socio-economic aspects", this paper discusses an evaluation of current practices during Halal and Shechita slaughter in cattle, sheep, goats and poultry. During religious slaughter, animals are killed with and without stunning by a transverse incision across the neck that is cutting the skin, muscles (brachiocephalic, sternocephalic, sternohyoid, and sternothyroid), trachea, esophagus, carotid arteries, jugular veins and the major, superficial and deep nerves of the cervical plexus. In this report, the restraint methods, stunning, neck cutting, exsanguination, slaughter techniques and postcut handling in the abattoir were assessed for religious slaughter. Information about the procedures used during religious slaughter in Belgium, Germany, Italy, the Netherlands, Spain, the UK, Turkey and Australia was collected by means of spot visits to abattoirs. To standardize the information gathered during the spot visits three guidelines were designed, one for each species, and translated into the national languages of the countries involved. The document included questions on the handling and restraint methods (stunning, neck cutting/exsanguination/slaughter techniques and postcut handling performed under religious practices) and for pain and distress of the animal during the restraint, neck cutting and induction to death in each abattoir. Results showed differences in the time from restraining to stun and to cut in the neck cutting procedures and in the time from cut to death. © 2013.

  2. Comparison of surface roughness and chip characteristics obtained under different modes of lubrication during hard turning of AISI H13 tool work steel.

    NASA Astrophysics Data System (ADS)

    Raj, Anil; Wins, K. Leo Dev; Varadarajan, A. S.

    2016-09-01

    Surface roughness is one of the important parameters, which not only affects the service life of a component but also serves as a good index of machinability. Near Dry Machining, methods (NDM) are considered as sustainable alternative for workshops trying to bring down their dependence on cutting fluids and the hazards associated with their indiscriminate usage. The present work presents a comparison of the surface roughness and chip characteristics during hard turning of AISI H13 tool work steel using hard metal inserts under two popular NDM techniques namely the minimal fluid application and the Minimum Quantity Lubrication technique(MQL) using an experiment designed based on Taguchi's techniques. The statistical method of analysis of variance (ANOVA) was used to determine the relative significance of input parameters consisting of cutting speed, feed and depth of cut on the attainable surface finish and the chip characteristics. It was observed that the performance during minimal fluid application was better than that during MQL application.

  3. Hybrid ABC Optimized MARS-Based Modeling of the Milling Tool Wear from Milling Run Experimental Data

    PubMed Central

    García Nieto, Paulino José; García-Gonzalo, Esperanza; Ordóñez Galán, Celestino; Bernardo Sánchez, Antonio

    2016-01-01

    Milling cutters are important cutting tools used in milling machines to perform milling operations, which are prone to wear and subsequent failure. In this paper, a practical new hybrid model to predict the milling tool wear in a regular cut, as well as entry cut and exit cut, of a milling tool is proposed. The model was based on the optimization tool termed artificial bee colony (ABC) in combination with multivariate adaptive regression splines (MARS) technique. This optimization mechanism involved the parameter setting in the MARS training procedure, which significantly influences the regression accuracy. Therefore, an ABC–MARS-based model was successfully used here to predict the milling tool flank wear (output variable) as a function of the following input variables: the time duration of experiment, depth of cut, feed, type of material, etc. Regression with optimal hyperparameters was performed and a determination coefficient of 0.94 was obtained. The ABC–MARS-based model's goodness of fit to experimental data confirmed the good performance of this model. This new model also allowed us to ascertain the most influential parameters on the milling tool flank wear with a view to proposing milling machine's improvements. Finally, conclusions of this study are exposed. PMID:28787882

  4. Hybrid ABC Optimized MARS-Based Modeling of the Milling Tool Wear from Milling Run Experimental Data.

    PubMed

    García Nieto, Paulino José; García-Gonzalo, Esperanza; Ordóñez Galán, Celestino; Bernardo Sánchez, Antonio

    2016-01-28

    Milling cutters are important cutting tools used in milling machines to perform milling operations, which are prone to wear and subsequent failure. In this paper, a practical new hybrid model to predict the milling tool wear in a regular cut, as well as entry cut and exit cut, of a milling tool is proposed. The model was based on the optimization tool termed artificial bee colony (ABC) in combination with multivariate adaptive regression splines (MARS) technique. This optimization mechanism involved the parameter setting in the MARS training procedure, which significantly influences the regression accuracy. Therefore, an ABC-MARS-based model was successfully used here to predict the milling tool flank wear (output variable) as a function of the following input variables: the time duration of experiment, depth of cut, feed, type of material, etc . Regression with optimal hyperparameters was performed and a determination coefficient of 0.94 was obtained. The ABC-MARS-based model's goodness of fit to experimental data confirmed the good performance of this model. This new model also allowed us to ascertain the most influential parameters on the milling tool flank wear with a view to proposing milling machine's improvements. Finally, conclusions of this study are exposed.

  5. Laser Cutting of Thin Nickel Bellows

    NASA Technical Reports Server (NTRS)

    Butler, C. L.

    1986-01-01

    Laser cutting technique produces narrow, precise, fast, and repeatable cuts in thin nickel-allow bellows material. Laser cutting operation uses intense focused beam to melt material and assisting gas to force melted material through part thickness, creating void. When part rotated or moved longitudinally, melting and material removal continuous and creates narrow, fast, precise, and repeatable cut. Technique used to produce cuts of specified depths less than material thickness. Avoids distortion, dents, and nicks produced in delicate materials during lathe trimming operations, which require high cutting-tool pressure and holding-fixture forces.

  6. Imaging Study of Multi-Crystalline Silicon Wafers Throughout the Manufacturing Process: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnston, S.; Yan, F.; Zaunbracher, K.

    2011-07-01

    Imaging techniques are applied to multi-crystalline silicon bricks, wafers at various process steps, and finished solar cells. Photoluminescence (PL) imaging is used to characterize defects and material quality on bricks and wafers. Defect regions within the wafers are influenced by brick position within an ingot and height within the brick. The defect areas in as-cut wafers are compared to imaging results from reverse-bias electroluminescence and dark lock-in thermography and cell parameters of near-neighbor finished cells. Defect areas are also characterized by defect band emissions. The defect areas measured by these techniques on as-cut wafers are shown to correlate to finishedmore » cell performance.« less

  7. A review of cutting mechanics and modeling techniques for biological materials.

    PubMed

    Takabi, Behrouz; Tai, Bruce L

    2017-07-01

    This paper presents a comprehensive survey on the modeling of tissue cutting, including both soft tissue and bone cutting processes. In order to achieve higher accuracy in tissue cutting, as a critical process in surgical operations, the meticulous modeling of such processes is important in particular for surgical tool development and analysis. This review paper is focused on the mechanical concepts and modeling techniques utilized to simulate tissue cutting such as cutting forces and chip morphology. These models are presented in two major categories, namely soft tissue cutting and bone cutting. Fracture toughness is commonly used to describe tissue cutting while Johnson-Cook material model is often adopted for bone cutting in conjunction with finite element analysis (FEA). In each section, the most recent mathematical and computational models are summarized. The differences and similarities among these models, challenges, novel techniques, and recommendations for future work are discussed along with each section. This review is aimed to provide a broad and in-depth vision of the methods suitable for tissue and bone cutting simulations. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  8. Influence of coolant on ductile mode processing of binderless nanocrystalline tungsten carbide through ultraprecision diamond turning

    NASA Astrophysics Data System (ADS)

    Doetz, Marius; Dambon, Olaf; Klocke, Fritz; Fähnle, Oliver

    2015-08-01

    Molds made of tungsten carbide are typically used for the replicative mass production of glass lenses by precision glass molding. Consequently an ultra-precision grinding process with a subsequent fresh-feed polishing operation is conventionally applied. These processes are time consuming and have a relatively low reproducibility. An alternative manufacturing technology, with a high predictability and efficiency, which additionally allows a higher geometrical flexibility, is the single point diamond turning technique (SPDT). However, the extreme hardness and the chemical properties of tungsten carbide lead to significant tool wear and therefore the impossibility of machining the work pieces in an economical way. One approach to enlarge the tool life is to affect the contact zone between tool and work piece by the use of special cutting fluids. This publication emphasizes on the most recent investigations and results in direct machining of nano-grained tungsten carbide with mono crystal diamonds under the influence of various kinds of cutting fluids. Therefore basic ruling experiments on binderless nano grained tungsten carbide were performed, where the tool performed a linear movement with a steadily increasing depth of cut. As the ductile cutting mechanism is a prerequisite for the optical manufacturing of tungsten carbide these experiments serve the purpose for establish the influence of different cutting fluid characteristics on the cutting performance of mono crystal diamonds. Eventually it is shown that by adjusting the coolant fluid it is possible to significantly shift the transition point from ductile to brittle removal to larger depths of cut eventually enabling a SPDT of binderless tungsten carbide molds.

  9. Drill hole logging with infrared spectroscopy

    USGS Publications Warehouse

    Calvin, W.M.; Solum, J.G.

    2005-01-01

    Infrared spectroscopy has been used to identify rocks and minerals for over 40 years. The technique is sensitive to primary silicates as well as alteration products. Minerals can be uniquely identified based on multiple absorption features at wavelengths from the visible to the thermal infrared. We are currently establishing methods and protocols in order to use the technique for rapid assessment of downhole lithology on samples obtained during drilling operations. Initial work performed includes spectral analysis of chip cuttings and core sections from drill sites around Desert Peak, NV. In this paper, we report on a survey of 10,000 feet of drill cuttings, at 100 foot intervals, from the San Andreas Fault Observatory at Depth (SAFOD). Data from Blue Mountain geothermal wells will also be acquired. We will describe the utility of the technique for rapid assessment of lithologic and mineralogic discrimination.

  10. PERFORMANCE EVALUATION OF AN INNOVATIVE FIBER REINFORCED GEOPOLYMER SPRAY-APPLIED MORTAR FOR LARGE DIAMETER WASTEWATER MAIN REHABILITATION IN HOUSTON, TX

    EPA Science Inventory

    This report describes the performance evaluation of a fiber reinforced geopolymer spray-applied mortar, which has potential as a structural alternative to traditional open cut techniques used in large-diameter sewer pipes. Geopolymer is a sustainable green material that incorpor...

  11. Piezosurgery to perform hyoid bone osteotomies in thyroglossal duct cyst surgery.

    PubMed

    Salgarelli, Attilio Carlo; Robiony, Massimo; Consolo, Ugo; Collini, Marco; Bellini, Pierantonio

    2011-11-01

    Ultrasonic bone-cutting surgery has been introduced as a feasible alternative to the conventional sharp instruments used in craniomaxillofacial surgery because of its precision and safety. The device used is unique in that the cutting action occurs when the tool is used on mineralized tissues and stops on soft tissues. This work describes the use of piezosurgery for hyoid bone resection in thyroglossal duct cyst surgery, briefly reviews the literature on the surgical technique, and reports our experience with 12 cases.

  12. Wear measurement of the cutting edge of superhard turning tools using TLA technique

    NASA Astrophysics Data System (ADS)

    Vasváry, L.; Ditrói, F.; Takács, S.; Szabó, Z.; Szűcs, J.; Kundrák, J.; Mahunka, I.

    1994-03-01

    Wear measurement on superhard boron nitride and artificial diamond turning tools was performed using thin layer activation (TLA) technique. The samples were irradiated in two different geometries to improve the sensitivity of the method and change the region of wear to be investigated. The most proper irradiation parameters and nuclear reactions were investigated for both kind of tools.

  13. Real-time haptic cutting of high-resolution soft tissues.

    PubMed

    Wu, Jun; Westermann, Rüdiger; Dick, Christian

    2014-01-01

    We present our systematic efforts in advancing the computational performance of physically accurate soft tissue cutting simulation, which is at the core of surgery simulators in general. We demonstrate a real-time performance of 15 simulation frames per second for haptic soft tissue cutting of a deformable body at an effective resolution of 170,000 finite elements. This is achieved by the following innovative components: (1) a linked octree discretization of the deformable body, which allows for fast and robust topological modifications of the simulation domain, (2) a composite finite element formulation, which thoroughly reduces the number of simulation degrees of freedom and thus enables to carefully balance simulation performance and accuracy, (3) a highly efficient geometric multigrid solver for solving the linear systems of equations arising from implicit time integration, (4) an efficient collision detection algorithm that effectively exploits the composition structure, and (5) a stable haptic rendering algorithm for computing the feedback forces. Considering that our method increases the finite element resolution for physically accurate real-time soft tissue cutting simulation by an order of magnitude, our technique has a high potential to significantly advance the realism of surgery simulators.

  14. Comparison of nerve trimming with the Er:YAG laser and steel knife

    NASA Astrophysics Data System (ADS)

    Josephson, G. D.; Bass, Lawrence S.; Kasabian, A. K.

    1995-05-01

    Best outcome in nerve repair requires precise alignment and minimization of scar at the repair interface. Surgeons attempt to create the sharpest cut surface at the nerve edge prior to approximation. Pulsed laser modalities are being investigated in several medical applications which require precise atraumatic cutting. We compared nerve trimming with the Er:YAG laser (1375 J/cm2) to conventional steel knife trimming prior to neurorrhaphy. Sprague- Dawley rats were anesthetized with ketamine and xylazine. Under operating microscope magnification the sciatic nerve was dissected and transected using one of the test techniques. In the laser group, the pulses were directed axially across the nerve using a stage which fixed laser fiber/nerve distance and orientation. Specimens were sent for scanning electron microscopy (SEM) at time zero. Epineurial repairs were performed with 10 - 0 nylon simple interrupted sutures. At intervals to 90 days, specimens were harvested and sectioned longitudinally and axially for histologic examination. Time zero SEM revealed clean cuts in both groups but individual axons were clearly visible in all laser specimens. Small pits were also visible on the cut surface of laser treated nerves. No significant differences in nerve morphology were seen during healing. Further studies to quantify axon counts, and functional outcome will be needed to assess this technique of nerve trimming. Delivery system improvements will also be required, to make the technique clinically practical.

  15. ESDA®-Lite collection of DNA from latent fingerprints on documents.

    PubMed

    Plaza, Dane T; Mealy, Jamia L; Lane, J Nicholas; Parsons, M Neal; Bathrick, Abigail S; Slack, Donia P

    2015-05-01

    The ability to detect and non-destructively collect biological samples for DNA processing would benefit the forensic community by preserving the physical integrity of evidentiary items for more thorough evaluations by other forensic disciplines. The Electrostatic Detection Apparatus (ESDA®) was systemically evaluated for its ability to non-destructively collect DNA from latent fingerprints deposited on various paper substrates for short tandem repeat (STR) DNA profiling. Fingerprints were deposited on a variety of paper substrates that included resume paper, cotton paper, magazine paper, currency, copy paper, and newspaper. Three DNA collection techniques were performed: ESDA collection, dry swabbing, and substrate cutting. Efficacy of each collection technique was evaluated by the quantity of DNA present in each sample and the percent profile generated by each sample. Both the ESDA and dry swabbing non-destructive sampling techniques outperformed the destructive methodology of substrate cutting. A greater number of full profiles were generated from samples collected with the non-destructive dry swabbing collection technique than were generated from samples collected with the ESDA; however, the ESDA also allowed the user to visualize the area of interest while non-destructively collecting the biological material. The ability to visualize the biological material made sampling straightforward and eliminated the need for numerous, random swabbings/cuttings. Based on these results, the evaluated non-destructive ESDA collection technique has great potential for real-world forensic implementation. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  16. Simulation of router action on a lathe to test the cutting tool performance in edge-trimming of graphite/epoxy composite

    NASA Astrophysics Data System (ADS)

    Ramulu, M.; Rogers, E.

    1994-04-01

    The predominant machining application with graphite/epoxy composite materials in aerospace industry is peripheral trimming. The computer numerically controlled (CNC) high speed routers required to do edge trimming work are generally scheduled for production work in industry and are not available for extensive cutter testing. Therefore, an experimental method of simulating the conditions of periphery trim using a lathe is developed in this paper. The validity of the test technique will be demonstrated by conducting carbide tool wear tests under dry cutting conditions. The experimental results will be analyzed to characterize the wear behavior of carbide cutting tools in machining the composite materials.

  17. Design and Performance of Property Gradient Ternary Nitride Coating Based on Process Control.

    PubMed

    Yan, Pei; Chen, Kaijie; Wang, Yubin; Zhou, Han; Peng, Zeyu; Jiao, Li; Wang, Xibin

    2018-05-09

    Surface coating is an effective approach to improve cutting tool performance, and multiple or gradient coating structures have become a common development strategy. However, composition mutations at the interfaces decrease the performance of multi-layered coatings. The key mitigation technique has been to reduce the interface effect at the boundaries. This study proposes a structure design method for property-component gradient coatings based on process control. The method produces coatings with high internal cohesion and high external hardness, which could reduce the composition and performance mutations at the interface. A ZrTiN property gradient ternary nitride coating was deposited on cemented carbide by multi-arc ion plating with separated Ti and Zr targets. The mechanical properties, friction behaviors, and cutting performances were systematically investigated, compared with a single-layer coating. The results indicated that the gradient coating had better friction and wear performance with lower wear rate and higher resistance to peeling off during sliding friction. The gradient coating had better wear and damage resistance in cutting processes, with lower machined surface roughness Ra. Gradient-structured coatings could effectively inhibit micro crack initiation and growth under alternating force and temperature load. This method could be extended to similar ternary nitride coatings.

  18. Cost minimizing of cutting process for CNC thermal and water-jet machines

    NASA Astrophysics Data System (ADS)

    Tavaeva, Anastasia; Kurennov, Dmitry

    2015-11-01

    This paper deals with optimization problem of cutting process for CNC thermal and water-jet machines. The accuracy of objective function parameters calculation for optimization problem is investigated. This paper shows that working tool path speed is not constant value. One depends on some parameters that are described in this paper. The relations of working tool path speed depending on the numbers of NC programs frames, length of straight cut, configuration part are presented. Based on received results the correction coefficients for working tool speed are defined. Additionally the optimization problem may be solved by using mathematical model. Model takes into account the additional restrictions of thermal cutting (choice of piercing and output tool point, precedence condition, thermal deformations). At the second part of paper the non-standard cutting techniques are considered. Ones may lead to minimizing of cutting cost and time compared with standard cutting techniques. This paper considers the effectiveness of non-standard cutting techniques application. At the end of the paper the future research works are indicated.

  19. Mechanical pre-cutting, a rediscovered tunneling technique

    NASA Astrophysics Data System (ADS)

    van Walsum, E.

    1991-04-01

    In 1950, the exact outlines of some circular tunnels, to be driven through chalk for the Corps of Engineers' Fort Randall Reservoir Project on the Missouri River at Pickstown, South Dakota, U.S.A., were pre-cut mechanically, i. e. prior to blasting the tunnel openings. No further applications of mechanical pre-cutting as a tunneling technique were made until the technique was rediscovered and further developed in France during the seventies. These further developments relate to the pre-cutting of harder rocks and the pre-cutting of cohesive and non-cohesive soils combined with the construction of a concrete pre-lining, i. e. a lining which is in place before the ground under it is excavated. Mechanical pre-cutting, as presently practiced, improves the quality and safety of tunneling and reduces surface settlement, noise and vibration. It is concluded that the technique is likely to be applied in the future in the construction of various types of underground structures whenever conventional tunneling is too risky or when environmental concerns are important.

  20. Retrograde endopyelotomy: a comparison between laser and Acucise balloon cutting catheter.

    PubMed

    el-Nahas, Ahmed R

    2007-03-01

    Endopyelotomy and laparoscopic pyeloplasty are the preferred modalities for treatment of ureteropelvic junction obstruction because of their minimally invasive nature. There are continuous efforts for improving endopyelotomy techniques and outcome. Retrograde access represents the natural evolution of endopyelotomy. The Acucise cutting balloon catheter (Applied Medical Resources Corp., Laguna Hills, CA) and ureteroscopic endopyelotomy using holmium laser are the most widely accepted techniques. The Acucise catheter was developed to simplify retrograde endopyelotomy and made it possible for all urologists, regardless of their endourologic skills. The Acucise catheter depends on incision and dilatation of the ureteropelvic junction under fluoroscopic guidance, whereas ureteroscopy allows visual control of the site, depth, and extent of the incision; the holmium laser is a perfect method for a clean precise incision. Review of the English literature showed that the Acucise technique was more widely performed, though laser had better (but not statistically significant) safety and efficacy profiles.

  1. Dual Laser-Assisted Lamellar Anterior Keratoplasty with Tophat Graft: A Laboratory Study

    PubMed Central

    Cleary, Catherine; Song, Jonathan C.; Tang, Maolong; Li, Yan; Liu, Ying; Yiu, Samuel; Huang, David

    2011-01-01

    Objectives To develop a dual laser-assisted lamellar anterior keratoplasty (LALAK) technique, using excimer and femtosecond lasers to perform surgery on eye-bank eyes. Methods First we compared corneal stromal surfaces produced by (1) deep excimer ablation, (2) femtosecond lamellar cuts, and (3) manual dissection, and evaluated the effect of excimer laser smoothing with fluid masking on each surface. Masked observers graded scanning electron microscopy (SEM) images on a 5-point roughness scale. Then we performed a 6-mm diameter excimer laser phototherapeutic keratectomy (PTK) ablation to a residual bed thickness of 200μm, followed by laser smoothing. We used the femtosecond laser to cut donors in a modified top-hat design with a thin tapered brim, which fitted into a manually dissected circumferential pocket at the base of the recipient bed. Fourier-domain optical coherence tomography (OCT) was used to measure corneal pachymetry and evaluate graft fit. Results Deep excimer ablation with smoothing (n=4) produced a significantly (p<0.05) smoother surface (grade=3.5) than deep excimer alone (n=4, grade=3.8) or manual dissection with (n=1, grade=3.8) and without smoothing (n=1, grade=4.8). Deep femtosecond cuts (n=2) produced macroscopic concentric ridges on the stromal surface. Experimental LALAK was performed on 4 recipients prepared by deep excimer ablation and 4 donors cut with the femtosecond laser. After suturing good peripheral graft-host match was observed on FD-OCT imaging. Conclusion These preliminary studies show that the LALAK technique permits improved interface smoothness and graft edge matching. Clinical trials are needed to determine whether these improvements can translate to better vision. PMID:22378114

  2. The Cooling and Lubrication Performance of Graphene Platelets in Micro-Machining Environments

    NASA Astrophysics Data System (ADS)

    Chu, Bryan

    The research presented in this thesis is aimed at investigating the use of graphene platelets (GPL) to address the challenges of excessive tool wear, reduced part quality, and high specific power consumption encountered in micro-machining processes. There are two viable methods of introducing GPL into micro-machining environments, viz., the embedded delivery method, where the platelets are embedded into the part being machined, and the external delivery method, where graphene is carried into the cutting zone by jetting or atomizing a carrier fluid. The study involving the embedded delivery method is focused on the micro-machining performance of hierarchical graphene composites. The results of this study show that the presence of graphene in the epoxy matrix improves the machinability of the composite. In general, the tool wear, cutting forces, surface roughness, and extent of delamination are all seen to be lower for the hierarchical composite when compared to the conventional two-phase glass fiber composite. These improvements are attributed to the fact that graphene platelets improve the thermal conductivity of the matrix, provide lubrication at the tool-chip interface and also improve the interface strength between the glass fibers and the matrix. The benefits of graphene are seen to also carry over to the external delivery method. The platelets provide improved cooling and lubrication performance to both environmentally-benign cutting fluids as well as to semi-synthetic cutting fluids used in micro-machining. The cutting performance is seen to be a function of the geometry (i.e., lateral size and thickness) and extent of oxygen-functionalization of the platelet. Ultrasonically exfoliated platelets (with 2--3 graphene layers and lowest in-solution characteristic lateral length of 120 nm) appear to be the most favorable for micro-machining applications. Even at the lowest concentration of 0.1 wt%, they are capable of providing a 51% reduction in the cutting temperature and a 25% reduction in the surface roughness value over that of the baseline semi-synthetic cutting fluid. For the thermally-reduced platelets (with 4--8 graphene layers and in-solution characteristic lateral length of 562--2780 nm), a concentration of 0.2 wt% appears to be optimal. An investigation into the impingement dynamics of the graphene-laden colloidal solutions on a heated substrate reveals that the most important criterion dictating their machining performance is their ability to form uniform, submicron thick films of the platelets upon evaporation of the carrier fluid. As such, the characterization of the residual platelet film left behind on a heated substrate may be an effective technique for evaluating different graphene colloidal solutions for cutting fluids applications in micromachining. Graphene platelets have also recently been shown to reduce the aggressive chemical wear of diamond tools during the machining of transition metal alloys. However, the specific mechanisms responsible for this improvement are currently unknown. The modeling work presented in this thesis uses molecular dynamics techniques to shed light on the wear mitigation mechanisms that are active during the diamond cutting of steel when in the presence of graphene platelets. The dual mechanisms responsible for graphene-induced chemical wear mitigation are: 1) The formation of a physical barrier between the metal and tool atoms, preventing graphitization; and 2) The preferential transfer of carbon from the graphene platelet rather than from the diamond tool. The results of the simulations also provide new insight into the behavior of the 2D graphene platelets in the cutting zone, specifically illustrating the mechanisms of cleaving and interlayer sliding in graphene platelets under the high pressures in cutting zones.

  3. A novel toolpath force prediction algorithm using CAM volumetric data for optimizing robotic arthroplasty.

    PubMed

    Kianmajd, Babak; Carter, David; Soshi, Masakazu

    2016-10-01

    Robotic total hip arthroplasty is a procedure in which milling operations are performed on the femur to remove material for the insertion of a prosthetic implant. The robot performs the milling operation by following a sequential list of tool motions, also known as a toolpath, generated by a computer-aided manufacturing (CAM) software. The purpose of this paper is to explain a new toolpath force prediction algorithm that predicts cutting forces, which results in improving the quality and safety of surgical systems. With a custom macro developed in the CAM system's native application programming interface, cutting contact patch volume was extracted from CAM simulations. A time domain cutting force model was then developed through the use of a cutting force prediction algorithm. The second portion validated the algorithm by machining a hip canal in simulated bone using a CNC machine. Average cutting forces were measured during machining using a dynamometer and compared to the values predicted from CAM simulation data using the proposed method. The results showed the predicted forces matched the measured forces in both magnitude and overall pattern shape. However, due to inconsistent motion control, the time duration of the forces was slightly distorted. Nevertheless, the algorithm effectively predicted the forces throughout an entire hip canal procedure. This method provides a fast and easy technique for predicting cutting forces during orthopedic milling by utilizing data within a CAM software.

  4. Mitigation of EMU Cut Glove Hazard from Micrometeoroid and Orbital Debris Impacts on ISS Handrails

    NASA Technical Reports Server (NTRS)

    Ryan, Shannon; Christiansen, Eric L.; Davis, Bruce A.; Ordonez, Erick

    2009-01-01

    Recent cut damages sustained on crewmember gloves during extravehicular activity (ISS) onboard the International Space Station (ISS) have been caused by contact with sharp edges or a pinch point according to analysis of the damages. One potential source are protruding sharp edged crater lips from micrometeoroid and orbital debris (MMOD) impacts on metallic handrails along EVA translation paths. A number of hypervelocity impact tests were performed on ISS handrails, and found that mm-sized projectiles were capable of inducing crater lip heights two orders of magnitude above the minimum value for glove abrasion concerns. Two techniques were evaluated for mitigating the cut glove hazard of MMOD impacts on ISS handrails: flexible overwraps which act to limit contact between crewmember gloves and impact sites, and; alternate materials which form less hazardous impact crater profiles. In parallel with redesign efforts to increase the cut resilience of EMU gloves, the modifications to ISS handrails evaluated in this study provide the means to significantly reduce cut glove risk from MMOD impact craters

  5. Resection with laser and high frequency cutting loop in tracheo-bronchial diseases.

    PubMed

    Illum, P

    1989-04-01

    A total of 23 patients have been treated endoscopically during the last three and a half years for a variety of diseases in the tracheo-bronchial tree; nine had a tracheal stenosis. Thirteen patients have been treated by resection with a high frequency cutting loop, eleven with a CO2-laser and one with an argon laser. A total of 44 treatments have been performed. Half of the treatments were given because of various malignant diseases. The results of the treatment of this very mixed group of patients were, as a whole, satisfactory with both CO2-laser and cutting loop. A more precise technique can be applied with the CO2-laser than the cutting loop, though the latter is the more efficient and easy to work with. Care must be taken with the loop because of its greater cutting depth. The argon laser has only limited use in the treatment of diseases in the trachea.

  6. Fluorescence hyperspectral imaging technique for the foreign substance detection on fresh-cut lettuce

    USDA-ARS?s Scientific Manuscript database

    Nondestructive methods based on fluorescence hyperspectral imaging (HSI) techniques were developed in order to detect worms on fresh-cut lettuce. The optimal wavebands for detecting worms on fresh-cut lettuce were investigated using the one-way ANOVA analysis and correlation analysis. The worm detec...

  7. Technique for finding and identifying filters that cut off OTDR lights in front of ONU from a central office

    NASA Astrophysics Data System (ADS)

    Takaya, Masaaki; Honda, Hiroyasu; Narita, Yoshihiro; Yamamoto, Fumihiko; Arakawa, Koji

    2006-04-01

    We report on a newly developed in-service measurement technique that can be used from a central office to find and identify any filter in front of an ONU on an optical fiber access network. Using this system, in-service tests can be performed because the test lights are modulated at a high frequency. Moreover, by using the equipment we developed, this confirmation operation can be performed continuously and automatically with existing automatic fiber testing systems. The developed technique is effective for constructing a fiber line testing system with an optical time domain reflectometer.

  8. Membrane technology for treating of waste nanofluids coolant: A review

    NASA Astrophysics Data System (ADS)

    Mohruni, Amrifan Saladin; Yuliwati, Erna; Sharif, Safian; Ismail, Ahmad Fauzi

    2017-09-01

    The treatment of cutting fluids wastes concerns a big number of industries, especially from the machining operations to foster environmental sustainability. Discharging cutting fluids, waste through separation technique could protect the environment and also human health in general. Several methods for the separation emulsified oils or oily wastewater have been proposed as three common methods, namely chemical, physicochemical and mechanical and membrane technology application. Membranes are used into separate and concentrate the pollutants in oily wastewater through its perm-selectivity. Meanwhile, the desire to compensate for the shortcomings of the cutting fluid media in a metal cutting operation led to introduce the using of nanofluids (NFs) in the minimum quantity lubricant (MQL) technique. NFs are prepared based on nanofluids technology by dispersing nanoparticles (NPs) in liquids. These fluids have potentially played to enhance the performance of traditional heat transfer fluids. Few researchers have studied investigation of the physical-chemical, thermo-physical and heat transfer characteristics of NFs for heat transfer applications. The use of minimum quantity lubrication (MQL) technique by NFs application is developed in many metal cutting operations. MQL did not only serve as a better alternative to flood cooling during machining operation and also increases better-finished surface, reduces impact loads on the environment and fosters environmental sustainability. Waste coolant filtration from cutting tools using membrane was treated by the pretreated process, coagulation technique and membrane filtration. Nanomaterials are also applied to modify the membrane structure and morphology. Polyvinylidene fluoride (PVDF) is the better choice in coolant wastewater treatment due to its hydrophobicity. Using of polyamide nanofiltration membranes BM-20D and UF-PS-100-100, 000, it resulted in the increase of permeability of waste coolant filtration. Titanium dioxide is nanomaterials additive to modify the Nanopores of the surface membrane. Contact angle and average pore size were used in the investigation of the surface morphology of membranes. An adequate choice in modifying the membrane surface in waste coolant filtration may bring a promised alternative as a solution in waste coolant remediation.

  9. Material cutting, shaping, and forming: A compilation

    NASA Technical Reports Server (NTRS)

    1974-01-01

    Information is presented concerning cutting, shaping, and forming of materials, and the equipment and techniques required for utilizing these materials. The use of molds, electrical fields, and mechanical devices are related to forming materials. Material cutting methods by devices including borers and slicers are presented along with chemical techniques. Shaping and fabrication techniques are described for tubing, honeycomb panels, and ceramic structures. The characteristics of the materials are described. Patent information is included.

  10. Preserving the PCL during the tibial cut in total knee arthroplasty.

    PubMed

    Cinotti, G; Sessa, P; Amato, M; Ripani, F R; Giannicola, G

    2017-08-01

    Previous studies have shown that the PCL insertion may be damaged during the tibial cut performed in total knee arthroplasty. We investigated the maximum thickness of a tibial cut that preserves the PCL insertion and to what extent the posterior slope of the tibial cut and that of the patient's tibial plateaus affect the outcome. MR images of 83 knees were analysed. The maximum thickness of a tibial cut that preserves the PCL using a posterior slope of 0°, 3°, 5° and parallel to the patient's slope of the tibial plateau, was evaluated. Correlations between the results and the degrees of the posterior slope of the patient's tibial plateaus were also investigated. The maximum thickness of a tibial cut that preserves the entire PCL insertion was, on average, 5.5, 4.7, 4.2 and 3.1 mm when a posterior slope of 0°, 3°, 5° and parallel to the patients' tibial plateaus was used, respectively. When the 25th percentile was considered, the maximum thickness of a tibial cut that preserved the PCL was 4 and 3 mm with a tibial cut of 0° and 5° of posterior slope, respectively. The maximum thickness of a tibial cut that preserved the PCL was significantly greater in patients with a sagittal slope of the tibial plateaus more than 8° than in those with a sagittal slope less than 8°. In cruciate retaining implants, the PCL insertion may be spared in the majority of patients by performing a tibial cut of 4 mm, or even less when a posterior slope of 3°-5° is used. The clinical relevance of our study is that the execution of a conservative tibial cut, followed by a second tibial resection to achieve the thickness required for the tibial component to be implanted, may be an alternative technique to spare the PCL in CR TKA. II.

  11. Laser cutting: industrial relevance, process optimization, and laser safety

    NASA Astrophysics Data System (ADS)

    Haferkamp, Heinz; Goede, Martin; von Busse, Alexander; Thuerk, Oliver

    1998-09-01

    Compared to other technological relevant laser machining processes, up to now laser cutting is the application most frequently used. With respect to the large amount of possible fields of application and the variety of different materials that can be machined, this technology has reached a stable position within the world market of material processing. Reachable machining quality for laser beam cutting is influenced by various laser and process parameters. Process integrated quality techniques have to be applied to ensure high-quality products and a cost effective use of the laser manufacturing plant. Therefore, rugged and versatile online process monitoring techniques at an affordable price would be desirable. Methods for the characterization of single plant components (e.g. laser source and optical path) have to be substituted by an omnivalent control system, capable of process data acquisition and analysis as well as the automatic adaptation of machining and laser parameters to changes in process and ambient conditions. At the Laser Zentrum Hannover eV, locally highly resolved thermographic measurements of the temperature distribution within the processing zone using cost effective measuring devices are performed. Characteristic values for cutting quality and plunge control as well as for the optimization of the surface roughness at the cutting edges can be deducted from the spatial distribution of the temperature field and the measured temperature gradients. Main influencing parameters on the temperature characteristic within the cutting zone are the laser beam intensity and pulse duration in pulse operation mode. For continuous operation mode, the temperature distribution is mainly determined by the laser output power related to the cutting velocity. With higher cutting velocities temperatures at the cutting front increase, reaching their maximum at the optimum cutting velocity. Here absorption of the incident laser radiation is drastically increased due to the angle between the normal of the cutting front and the laser beam axis. Beneath process optimization and control further work is focused on the characterization of particulate and gaseous laser generated air contaminants and adequate safety precautions like exhaust and filter systems.

  12. Three-Dimensional Profiles Using a Spherical Cutting Bit: Problem Solving in Practice

    ERIC Educational Resources Information Center

    Ollerton, Richard L.; Iskov, Grant H.; Shannon, Anthony G.

    2002-01-01

    An engineering problem concerned with relating the coordinates of the centre of a spherical cutting tool to the actual cutting surface leads to a potentially rich example of problem-solving techniques. Basic calculus, Lagrange multipliers and vector calculus techniques are employed to produce solutions that may be compared to better understand…

  13. Novel air-injection technique to locate the medial cut end of lacerated canaliculus.

    PubMed

    Liu, Bingqian; Li, Yonghao; Long, Chongde; Wang, Zhonghao; Liang, Xuanwei; Ge, Jian; Wang, Zhichong

    2013-12-01

    Locating the medial cut end of the severed canaliculus is the most difficult aspect of canalicular repair, especially in patients with more medial laceration, severe oedema, persistent errhysis and a narrow canaliculus. Irrigation is a widely used technique to identify the cut end; however, we found that air injected through the intact canaliculus with a straight needle failed to reflux when the common canaliculus or lacrimal sac was not blocked. We describe a simple, safe and efficient air-injection technique to identify the medial cut edge of a lacerated canaliculus. In this method, we initially submersed the medial canthus under normal saline, then injected filtered air through the intact canaliculus using a side port stainless steel probe with a closed round tip. The tip was designed to block the common canaliculus to form a relatively closed system. The efficiency of this novel air-injection technique was equivalent to the traditional technique but does not require the cooperation of the patient to blow air. Using this technique, the medial cut end was successfully identified by locating the air-bubble exit within minutes in 19 cases of mono-canalicular laceration without any complication.

  14. Modelling of tunnelling processes and rock cutting tool wear with the particle finite element method

    NASA Astrophysics Data System (ADS)

    Carbonell, Josep Maria; Oñate, Eugenio; Suárez, Benjamín

    2013-09-01

    Underground construction involves all sort of challenges in analysis, design, project and execution phases. The dimension of tunnels and their structural requirements are growing, and so safety and security demands do. New engineering tools are needed to perform a safer planning and design. This work presents the advances in the particle finite element method (PFEM) for the modelling and the analysis of tunneling processes including the wear of the cutting tools. The PFEM has its foundation on the Lagrangian description of the motion of a continuum built from a set of particles with known physical properties. The method uses a remeshing process combined with the alpha-shape technique to detect the contacting surfaces and a finite element method for the mechanical computations. A contact procedure has been developed for the PFEM which is combined with a constitutive model for predicting the excavation front and the wear of cutting tools. The material parameters govern the coupling of frictional contact and wear between the interacting domains at the excavation front. The PFEM allows predicting several parameters which are relevant for estimating the performance of a tunnelling boring machine such as wear in the cutting tools, the pressure distribution on the face of the boring machine and the vibrations produced in the machinery and the adjacent soil/rock. The final aim is to help in the design of the excavating tools and in the planning of the tunnelling operations. The applications presented show that the PFEM is a promising technique for the analysis of tunnelling problems.

  15. Factors affecting microcuttings of Stevia using a mist-chamber propagation box.

    PubMed

    Osman, Mohamad; Samsudin, Nur Syamimi; Faruq, Golam; Nezhadahmadi, Arash

    2013-01-01

    Stevia rebaudiana Bertoni is a member of Compositae family. Stevia plant has zero calorie content and its leaves are estimated to be 300 times sweeter than sugar. This plant is believed to be the most ideal substitute for sugar and important to assist in medicinal value especially for diabetic patients. In this study, microcutting techniques using a mist-chamber propagation box were used as it was beneficial for propagation of Stevia and gave genetic uniformity to the plant. The effects of different treatments on root stimulation of Stevia in microcuttings technique were evaluated. Treatments studied were different sizes of shoot cuttings, plant growth regulators, lights, and shades. Data logger was used to record the mean value of humidity (>90% RH), light intensity (673-2045 lx), and temperature (28.6-30.1°C) inside the mist-chamber propagation box. From analysis of variance, there were significant differences between varieties and treatments in parameters studied (P < 0.05). For the size of shoot cuttings treatment, 6 nodes cuttings were observed to increase root number. As compared to control, shoot cuttings treated with indole butyric acid (IBA) had better performance regarding root length. Yellow light and 50% shade treatments showed higher root and leaf number and these conditions can be considered as crucial for potential propagation of Stevia.

  16. Optimum design of space storable gas/liquid coaxial injectors.

    NASA Technical Reports Server (NTRS)

    Burick, R. J.

    1972-01-01

    Review of the results of a program of single-element, cold-flow/hot-fire experiments performed for the purpose of establishing design criteria for a high-performance gas/liquid (FLOX/CH4) coaxial injector. The approach and the techniques employed resulted in the direct design of an injector that met or exceeded the performance and chamber compatibility goals of the program without any need for the traditional 'cut-and-try' development methods.

  17. The role of the implementation angle of cuttings of Phyllanthus sellowianus as a reference for a soil protection measure against surface erosion

    NASA Astrophysics Data System (ADS)

    Rauch, H. P.; Sutili, F. J.; Aschbacher, M.; Müller, B.

    2009-04-01

    Cutting plantation is a very common method of soil bioengineering techniques. The potential of vegetative reproduction is used to install a vegetation cover on eroded slopes to prevent surface erosion. The development of above and below biomass from parts of the stock plant in a very short time and the fast and easy propagation are one of the most important advantages of this soil bioengineering type. Several handbooks (Schiechtl, 1992; Florineth, 2004 and Zeh, 2007) suggest potential plants for vegetative reproduction and describe the procedure of plantation in detail. It is recommended that the cuttings are not driven vertically into the ground. A flat implementation angle guarantees a more uniform rooting of the cutting part driven into the soil, however there are no systematically investigations of the impact of the implementation angle on the biomass performance and consequently on the performance as a surface erosion protection measure. This paper shows results from field investigations focusing on the problem of the impact of the implementation angle of cuttings. In sum 75 specimens of the species of Phyllanthus sellowianus. The plant species was recommended as a native potential soil bioengineering plant by Sutili (s. Sutili, 2006). The cuttings were planted with an average length of 50 cm and diameter of 2 cm. The implementation angle differences between 90 (vertical) 45 and 10 degree. Two months after plantation all plants were excavated and the relevant plant data sets were collected in order to analyse the biomass performance. The field investigations are part of an integrated research project of the University of Natural Resources and Applied Life Sciences, Vienna and the Federal University of Santa Maria, Rio Grande do Sul - Brazil.

  18. Selection of Levels of Dressing Process Parameters by Using TOPSIS Technique for Surface Roughness of En-31 Work piece in CNC Cylindrical Grinding Machine

    NASA Astrophysics Data System (ADS)

    Patil, Sanjay S.; Bhalerao, Yogesh J.

    2017-02-01

    Grinding is metal cutting process used for mainly finishing the automobile components. The grinding wheel performance becomes dull by using it most of times. So it should be reshaping for consistent performance. It is necessary to remove dull grains of grinding wheel which is known as dressing process. The surface finish produced on the work piece is dependent on the dressing parameters in sub-sequent grinding operation. Multi-point diamond dresser has four important parameters such as the dressing cross feed rate, dressing depth of cut, width of the diamond dresser and drag angle of the dresser. The range of cross feed rate level is from 80-100 mm/min, depth of cut varies from 10 - 30 micron, width of diamond dresser is from 0.8 - 1.10mm and drag angle is from 40o - 500, The relative closeness to ideal levels of dressing parameters are found for surface finish produced on the En-31 work piece during sub-sequent grinding operation by using Technique of Order Preference by Similarity to Ideal Solution (TOPSIS).In the present work, closeness to ideal solution i.e. levels of dressing parameters are found for Computer Numerical Control (CNC) cylindrical angular grinding machine. After the TOPSIS technique, it is found that the value of Level I is 0.9738 which gives better surface finish on the En-31 work piece in sub-sequent grinding operation which helps the user to select the correct levels (combinations) of dressing parameters.

  19. Optical+NIR Quasar Selection with the SDSS and UKIDSS

    NASA Astrophysics Data System (ADS)

    Mehta, Sajjan S.; Mahon, R. G.; Richards, G. T.; Hewett, P. C.

    2010-01-01

    We present the details of an optical+near-IR quasar selection technique, which utilizes near-IR data from the UKIDSS Large Area Survey and the optical data from the Sloan Digital Sky Survey in the SDSS's deep "Stripe 82" region, which covers over 200 deg2. Our selection methods primarily consist of isolating potential candidates in giK and gJK color space, in which there exists a significant separation of the stellar locus from the quasar locus. Additionally, we discuss secondary techniques such as comparison of catalog magnitudes with aperture photometry, analysis of SDSS and UKIDSS morphological type classifications, and flag cuts. Our primary color-cut selections include most quasars with redshifts below 3.4, significantly increasing the completeness both to dust reddened quasars and quasars with redshifts z 2.7 in the SDSS footprint. A simple color cut in the UKIDSS LAS Stripe 82 regions reveals 4200 quasar candidates down to K=18. These NIR selections have been used to contribute to the Baryon Oscillation Spectroscopic Survey (BOSS), which is one of the four surveys of the SDSS-III collaboration. We additionally intend to use our NIR techniques to perform an 8-dimensional optical+NIR Bayesian selection of quasars for the AAOmege UKIDSS SDSS (AUS) survey.

  20. Old scissors to industrial automation: the impact of technologic evolution on worker's health.

    PubMed

    Teodoroski, Rita de Cassia Clark; Koppe, Vanessa Mazzocchi; Merino, Eugênio Andrés Díaz

    2012-01-01

    To cut a fabric, the professional performs different jobs and among them stands out the cut. The scissors has been the instrument most used for this activity. Over the years, technology has been conquering its space in the textile industry. However, despite the industrial automation able to offer subsidies to answer employment market demands, without appropriate orientation, the worker is exposed to the risks inherent at the job. Ergonomics is a science that search to promote the comfort and well being in consonance with efficacy. Its goals are properly well defined and clearly guide the actions aimed at transforming the working conditions. This study aimed to analyze the activity of cut tissues with a machine by a seamstress and the implications on their body posture. The methodology used was the observation technique and application of the Protocol RULA, where the result obtained was the level 3 and score 5, confirming that "investigations and changes are required soon". Conclude that using the machine to tissue cut should be encouraged, but in conjunction with orientations for improving posture while handling it. It seeks to prevent dysfunction of the musculoskeletal system that prevents employees from performing their work tasks efficiently and productively.

  1. Kinematic differences between optical motion capture and biplanar videoradiography during a jump-cut maneuver

    PubMed Central

    Miranda, Daniel L; Rainbow, Michael J; Crisco, Joseph J; Fleming, Braden C

    2012-01-01

    Jumping and cutting activities are investigated in many laboratories attempting to better understand the biomechanics associated with non-contact ACL injury. Optical motion capture is widely used; however, it is subject to soft tissue artifact (STA). Biplanar videoradiography offers a unique approach to collecting skeletal motion without STA. The goal of this study was to compare how STA affects the six-degree-of-freedom motion of the femur and tibia during a jump-cut maneuver associated with non-contact ACL injury. Ten volunteers performed a jump-cut maneuver while their landing leg was imaged using optical motion capture (OMC) and biplanar videoradiography. The within-bone motion differences were compared using anatomical coordinate systems for the femur and tibia, respectively. The knee joint kinematic measurements were compared during two periods: before and after ground contact. Over the entire activity, the within-bone motion differences between the two motion capture techniques were significantly lower for the tibia than the femur for two of the rotational axes (flexion/extension, internal/external) and the origin. The OMC and biplanar videoradiography knee joint kinematics were in best agreement before landing. Kinematic deviations between the two techniques increased significantly after contact. This study provides information on the kinematic discrepancies between OMC and biplanar videoradiography that can be used to optimize methods employing both technologies for studying dynamic in vivo knee kinematics and kinetics during a jump-cut maneuver. PMID:23084785

  2. Bricklaying Curriculum: Advanced Bricklaying Techniques. Instructional Materials. Revised.

    ERIC Educational Resources Information Center

    Turcotte, Raymond J.; Hendrix, Laborn J.

    This curriculum guide is designed to assist bricklaying instructors in providing performance-based instruction in advanced bricklaying. Included in the first section of the guide are units on customized or architectural masonry units; glass block; sills, lintels, and copings; and control (expansion) joints. The next two units deal with cut,…

  3. A field test of cut-off importance sampling for bole volume

    Treesearch

    Jeffrey H. Gove; Harry T. Valentine; Michael J. Holmes

    2000-01-01

    Cut-off importance sampling has recently been introduced as a technique for estimating bole volume to some point below the tree tip, termed the cut-off point. A field test of this technique was conducted on a small population of eastern white pine trees using dendrometry as the standard for volume estimation. Results showed that the differences in volume estimates...

  4. Learning curve for laparoscopic Heller myotomy and Dor fundoplication for achalasia

    PubMed Central

    Omura, Nobuo; Tsuboi, Kazuto; Hoshino, Masato; Yamamoto, Seryung; Akimoto, Shunsuke; Masuda, Takahiro; Kashiwagi, Hideyuki; Yanaga, Katsuhiko

    2017-01-01

    Purpose Although laparoscopic Heller myotomy and Dor fundoplication (LHD) is widely performed to address achalasia, little is known about the learning curve for this technique. We assessed the learning curve for performing LHD. Methods Of the 514 cases with LHD performed between August 1994 and March 2016, the surgical outcomes of 463 cases were evaluated after excluding 50 cases with reduced port surgery and one case with the simultaneous performance of laparoscopic distal partial gastrectomy. A receiver operating characteristic (ROC) curve analysis was used to identify the cut-off value for the number of surgical experiences necessary to become proficient with LHD, which was defined as the completion of the learning curve. Results We defined the completion of the learning curve when the following 3 conditions were satisfied. 1) The operation time was less than 165 minutes. 2) There was no blood loss. 3) There was no intraoperative complication. In order to establish the appropriate number of surgical experiences required to complete the learning curve, the cut-off value was evaluated by using a ROC curve (AUC 0.717, p < 0.001). Finally, we identified the cut-off value as 16 surgical cases (sensitivity 0.706, specificity 0.646). Conclusion Learning curve seems to complete after performing 16 cases. PMID:28686640

  5. Learning curve for laparoscopic Heller myotomy and Dor fundoplication for achalasia.

    PubMed

    Yano, Fumiaki; Omura, Nobuo; Tsuboi, Kazuto; Hoshino, Masato; Yamamoto, Seryung; Akimoto, Shunsuke; Masuda, Takahiro; Kashiwagi, Hideyuki; Yanaga, Katsuhiko

    2017-01-01

    Although laparoscopic Heller myotomy and Dor fundoplication (LHD) is widely performed to address achalasia, little is known about the learning curve for this technique. We assessed the learning curve for performing LHD. Of the 514 cases with LHD performed between August 1994 and March 2016, the surgical outcomes of 463 cases were evaluated after excluding 50 cases with reduced port surgery and one case with the simultaneous performance of laparoscopic distal partial gastrectomy. A receiver operating characteristic (ROC) curve analysis was used to identify the cut-off value for the number of surgical experiences necessary to become proficient with LHD, which was defined as the completion of the learning curve. We defined the completion of the learning curve when the following 3 conditions were satisfied. 1) The operation time was less than 165 minutes. 2) There was no blood loss. 3) There was no intraoperative complication. In order to establish the appropriate number of surgical experiences required to complete the learning curve, the cut-off value was evaluated by using a ROC curve (AUC 0.717, p < 0.001). Finally, we identified the cut-off value as 16 surgical cases (sensitivity 0.706, specificity 0.646). Learning curve seems to complete after performing 16 cases.

  6. Fluorescence hyperspectral imaging technique for foreign substance detection on fresh-cut lettuce.

    PubMed

    Mo, Changyeun; Kim, Giyoung; Kim, Moon S; Lim, Jongguk; Cho, Hyunjeong; Barnaby, Jinyoung Yang; Cho, Byoung-Kwan

    2017-09-01

    Non-destructive methods based on fluorescence hyperspectral imaging (HSI) techniques were developed to detect worms on fresh-cut lettuce. The optimal wavebands for detecting the worms were investigated using the one-way ANOVA and correlation analyses. The worm detection imaging algorithms, RSI-I (492-626)/492 , provided a prediction accuracy of 99.0%. The fluorescence HSI techniques indicated that the spectral images with a pixel size of 1 × 1 mm had the best classification accuracy for worms. The overall results demonstrate that fluorescence HSI techniques have the potential to detect worms on fresh-cut lettuce. In the future, we will focus on developing a multi-spectral imaging system to detect foreign substances such as worms, slugs and earthworms on fresh-cut lettuce. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  7. Evolutionary Bi-objective Optimization for Bulldozer and Its Blade in Soil Cutting

    NASA Astrophysics Data System (ADS)

    Sharma, Deepak; Barakat, Nada

    2018-02-01

    An evolutionary optimization approach is adopted in this paper for simultaneously achieving the economic and productive soil cutting. The economic aspect is defined by minimizing the power requirement from the bulldozer, and the soil cutting is made productive by minimizing the time of soil cutting. For determining the power requirement, two force models are adopted from the literature to quantify the cutting force on the blade. Three domain-specific constraints are also proposed, which are limiting the power from the bulldozer, limiting the maximum force on the bulldozer blade and achieving the desired production rate. The bi-objective optimization problem is solved using five benchmark multi-objective evolutionary algorithms and one classical optimization technique using the ɛ-constraint method. The Pareto-optimal solutions are obtained with the knee-region. Further, the post-optimal analysis is performed on the obtained solutions to decipher relationships among the objectives and decision variables. Such relationships are later used for making guidelines for selecting the optimal set of input parameters. The obtained results are then compared with the experiment results from the literature that show a close agreement among them.

  8. Haircutting Guide for Cosmetology Students.

    ERIC Educational Resources Information Center

    Baker, Linda M.

    Intended for use at any point in a beauty culture course, this student manual on haircutting implements and techniques focuses on two basic haircuts--page and short summer cut--to describe and illustrate basic cutting and shaping techniques. There are four major sections in the manual: (1) Hairshaping Implements and Techniques (Implements Used In…

  9. The risk of sacrificing the PCL in cruciate retaining total knee arthroplasty and the relationship to the sagittal inclination of the tibial plateau.

    PubMed

    Sessa, Pasquale; Fioravanti, Giulio; Giannicola, Giuseppe; Cinotti, Gianluca

    2015-01-01

    In cruciate retaining total knee arthroplasty (TKA), a partial avulsion of PCL may occur when en-bloc tibial osteotomy is performed. We evaluated the effects of a tibial cut performed with different degrees of posterior slope on PCL insertion and whether the results are affected by the sagittal inclination of the patient's tibial plateau. We selected 83 MRIs of knees showing mild or no degenerative changes. The effects of a simulated tibial cut performed with a posterior slope of 0°, 3°, 5° and parallel to the patient's tibial plateau inclination on PCL insertion in the proximal tibia were investigated. The results were correlated with the degree of posterior inclination of the tibial plateau. Every angle we used for the tibial cut caused a PCL avulsion greater than 50%. The percentage of PCL avulsion significantly increased with increasing the posterior slope of the tibial cut. Patients with sagittal tibial plateau inclination <5° showed greater PCL avulsion than those with sagittal inclination >8°. Most of the PCL insertion is likely to be sacrificed when resection of the proximal tibia is performed en-block. The risk of PCL avulsion is reduced in patients showing a marked posterior inclination of the tibial plateau, but even in this group of patients a surgical technique aimed at sparing most of the PCL insertion is necessary. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Ultra-high-Q phononic resonators on-chip at cryogenic temperatures

    NASA Astrophysics Data System (ADS)

    Kharel, Prashanta; Chu, Yiwen; Power, Michael; Renninger, William H.; Schoelkopf, Robert J.; Rakich, Peter T.

    2018-06-01

    Long-lived, high-frequency phonons are valuable for applications ranging from optomechanics to emerging quantum systems. For scientific as well as technological impact, we seek high-performance oscillators that offer a path toward chip-scale integration. Confocal bulk acoustic wave resonators have demonstrated an immense potential to support long-lived phonon modes in crystalline media at cryogenic temperatures. So far, these devices have been macroscopic with cm-scale dimensions. However, as we push these oscillators to high frequencies, we have an opportunity to radically reduce the footprint as a basis for classical and emerging quantum technologies. In this paper, we present novel design principles and simple microfabrication techniques to create high performance chip-scale confocal bulk acoustic wave resonators in a wide array of crystalline materials. We tailor the acoustic modes of such resonators to efficiently couple to light, permitting us to perform a non-invasive laser-based phonon spectroscopy. Using this technique, we demonstrate an acoustic Q-factor of 2.8 × 107 (6.5 × 106) for chip-scale resonators operating at 12.7 GHz (37.8 GHz) in crystalline z-cut quartz (x-cut silicon) at cryogenic temperatures.

  11. Do exercises used in injury prevention programmes modify cutting task biomechanics? A systematic review with meta-analysis.

    PubMed

    Pappas, Evangelos; Nightingale, Elizabeth J; Simic, Milena; Ford, Kevin R; Hewett, Timothy E; Myer, Gregory D

    2015-05-01

    Some injury prevention programmes aim to reduce the risk of ACL rupture. Although the most common athletic task leading to ACL rupture is cutting, there is currently no consensus on how injury prevention programmes influence cutting task biomechanics. To systematically review and synthesise the scientific literature regarding the influence of injury prevention programme exercises on cutting task biomechanics. The three largest databases (Medline, EMBASE and CINAHL) were searched for studies that investigated the effect of injury prevention programmes on cutting task biomechanics. When possible meta-analyses were performed. Seven studies met the inclusion criteria. Across all studies, a total of 100 participants received exercises that are part of ACL injury prevention programmes and 76 participants served in control groups. Most studies evaluated variables associated with the quadriceps dominance theory. The meta-analysis revealed decreased lateral hamstrings electromyography activity (p ≤ 0.05) while single studies revealed decreased quadriceps and increased medial hamstrings activity and decreased peak knee flexion moment. Findings from single studies reported that ACL injury prevention exercises reduce neuromuscular deficits (knee valgus moment, lateral trunk leaning) associated with the ligament and trunk dominance theories, respectively. The programmes we analysed appear most effective when they emphasise individualised biomechanical technique correction and target postpubertal women. The exercises used in injury prevention programmes have the potential to improve cutting task biomechanics by ameliorating neuromuscular deficits linked to ACL rupture, especially when they emphasise individualised biomechanical technique correction and target postpubertal female athletes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. Characteristics of Four Plant Species Used for Soil Bioengineering Techniques in River Bank Stabilization

    NASA Astrophysics Data System (ADS)

    Liu, Y.; Gao, J. R.; Lou, H. P.; Zhang, J. R.; Rauch, H. P.

    2010-05-01

    Use the potential values of soil bioengineering techniques are important for the wide attention river ecological restoration works in Beijing. At first, demand for basic knowledge of the technical and biological properties of plants is essential for development of such techniques. Species for each chosen plant material type should be selected with an emphasis on the following: suitability for anticipated environment conditions, reasonable availability in desired quantity and probability of successful establishment. Account on these criteria, four species which used as live staking and rooted cutting techniques were selected, namely, Salix X aureo-pendula, Salix cheilophila, Vitex negundo var. heterophylla and Amorpha fruticosa L.. And monitoring work was performed on three construction sites of Beijing. Various survival rates and morphological parameters data were collected. Concerning plants hydraulic and hydrological behavior, bending tests were used to analysis the flexibility of each plant species. The results from rate and morphological parameters monitoring show that: Salix cheilophila performed the best. Other three plants behaved satisfactorily in shoots or roots development respectively. In the bending test mornitoring, Salix cheilophila branch had the least broken number. Then were Salix X aureo-pendula and Amorpha fruticosa L.. Vitex negundo var. branch had the highest broken number, but it tolerated the highest amount of stress. All plant species should be considered in the future scientific research and construction works in Beijing. Keywords: River bank stabilization, live staking, rooted cutting

  13. Fabrication of Ge-on-insulator wafers by Smart-CutTM with thermal management for undamaged donor Ge wafers

    NASA Astrophysics Data System (ADS)

    Kim, Munho; Cho, Sang June; Jayeshbhai Dave, Yash; Mi, Hongyi; Mikael, Solomon; Seo, Jung-Hun; Yoon, Jung U.; Ma, Zhenqiang

    2018-01-01

    Newly engineered substrates consisting of semiconductor-on-insulator are gaining much attention as starting materials for the subsequent transfer of semiconductor nanomembranes via selective etching of the insulating layer. Germanium-on-insulator (GeOI) substrates are critically important because of the versatile applications of Ge nanomembranes (Ge NMs) toward electronic and optoelectronic devices. Among various fabrication techniques, the Smart-CutTM technique is more attractive than other methods because a high temperature annealing process can be avoided. Another advantage of Smart-CutTM is the reusability of the donor Ge wafer. However, it is very difficult to realize an undamaged Ge wafer because there exists a large mismatch in the coefficient of thermal expansion among the layers. Although an undamaged donor Ge wafer is a prerequisite for its reuse, research related to this issue has not yet been reported. Here we report the fabrication of 4-inch GeOI substrates using the direct wafer bonding and Smart-CutTM process with a low thermal budget. In addition, a thermo-mechanical simulation of GeOI was performed by COMSOL to analyze induced thermal stress in each layer of GeOI. Crack-free donor Ge wafers were obtained by annealing at 250 °C for 10 h. Raman spectroscopy and x-ray diffraction (XRD) indicated similarly favorable crystalline quality of the Ge layer in GeOI compared to that of bulk Ge. In addition, Ge p-n diodes using transferred Ge NM indicate a clear rectifying behavior with an on and off current ratio of 500 at ±1 V. This demonstration offers great promise for high performance transferrable Ge NM-based device applications.

  14. Study on electroplating technology of diamond tools for machining hard and brittle materials

    NASA Astrophysics Data System (ADS)

    Cui, Ying; Chen, Jian Hua; Sun, Li Peng; Wang, Yue

    2016-10-01

    With the development of the high speed cutting, the ultra-precision machining and ultrasonic vibration technique in processing hard and brittle material , the requirement of cutting tools is becoming higher and higher. As electroplated diamond tools have distinct advantages, such as high adaptability, high durability, long service life and good dimensional stability, the cutting tools are effective and extensive used in grinding hard and brittle materials. In this paper, the coating structure of electroplating diamond tool is described. The electroplating process flow is presented, and the influence of pretreatment on the machining quality is analyzed. Through the experimental research and summary, the reasonable formula of the electrolyte, the electroplating technologic parameters and the suitable sanding method were determined. Meanwhile, the drilling experiment on glass-ceramic shows that the electroplating process can effectively improve the cutting performance of diamond tools. It has laid a good foundation for further improving the quality and efficiency of the machining of hard and brittle materials.

  15. How to perform combined cutting balloon and high pressure balloon valvuloplasty for dogs with subaortic stenosis.

    PubMed

    Kleman, Mandi E; Estrada, Amara H; Maisenbacher, Herbert W; Prošek, Robert; Pogue, Brandon; Shih, Andre; Paolillo, Joseph A

    2012-01-01

    Subvalvular aortic stenosis (SAS) is one of the most common congenital cardiac malformations in dogs. Unfortunately, the long term success rate and survival data following either open heart surgery or catheter based intervention has been disappointing in dogs with severe subaortic stenosis. Medical therapy is currently the only standard recommended treatment option. A cutting balloon dilation catheter has been used successfully for resistant coronary artery and peripheral pulmonary arterial stenoses in humans. This catheter is unique in that it has the ability to cut, or score, the stenotic region prior to balloon dilatation of the stenosis. The use of cutting balloon valvuloplasty combined with high pressure valvuloplasty for dogs with severe subaortic stenosis has recently been reported to be a safe and feasible alternative therapeutic option. The following report describes this technique, outlines the materials required, and provides some 'tips' for successful percutaneous subaortic balloon valvuloplasty. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Improving soil bioengineering techniques to control erosion and sedimentation within the context of torrential Mediterranean climate: a French-Canadian experience

    NASA Astrophysics Data System (ADS)

    Rey, Freddy; Louis, Séverine; Burylo, Mélanie; Raymond, Pierre

    2013-04-01

    On marly eroded terrains of the French Southern Alps, many researches are undertaken in order to better understand the role of vegetation and bioengineering works on erosion and sedimentation control. To this view, the eroded marly gullies of the French Southern Alps are an experimental design where an original French strategy of rehabilitation, developed by scientists from Irstea (ex-Cemagref), has been tested since 2002. It is comprised of the construction of bioengineering works, namely of "brush layers and brush mats of cuttings on deadwood microdams", and implements the use of willow cuttings (Salix purpurea and S. incana). The main objective of these works is to sustainably trap and retain marly sediment, by checking their performance (growth and survival of the cuttings, sediment trapping) in a mountainous and Mediterranean climate. In Canada, several private companies have developed their own knowledge and expertise in the conception and building of bioengineering works for erosion control, especially in the context of hilly and mountainous landscapes and climates. Therefore, it was decided to use the competence and expertise of Terra Erosion Control Ltd., a Canadian company, in the French torrential Mediterranean climate. Ten modalities were tested, the aims being to develop and/or to modify existing designs of current techniques, to experiment with other live cuttings (Populus nigra) and rooted species (Alnus spp. and Hippophae spp.), to evaluate and compare the potential use of different organic soil amendments in order to increase beneficial soil microorganisms and finally, to evaluate the potential use of specialized tools and equipment in order to increase the efficiency of the installation for vegetation establishment and sediment trapping, while decreasing the implementation costs. The experimental design was installed in March 2011 and the early observations in Spring 2012 showed that: 1/ most of the cuttings and the plants resisted to burial and to drought conditions; in particular, the structures using wooden boards instead of locally harvested logs appeared to be holding up well; 2/ designs of current techniques with vertical cuttings were better for resprouting and sediment trapping; 3/ 0.8m live cuttings of Populus nigra may represent an alternative to Salix spp., but resprout appeared lower; 4/ it was not possible to evaluate the performance of rooted species (Alnus spp. and Hippophae spp.); therefore more experiment is needed, especially with longer plants; 5/ organic soil amendments may increase vegetation development (BRF > fertilizer > compost > mixes). By comparing the results with similar sites used as benchmarks, installed since 2002, further observations in the spring of 2013 will allow us to evaluate the efficiency of the different modalities to improve vegetation establishment and sediment trapping.

  17. The Orthogonal In-Situ Machining of Single and Polycrystalline Aluminum and Copper, Volume 1. Ph.D. Thesis Final Report

    NASA Technical Reports Server (NTRS)

    Cohen, P. H.

    1982-01-01

    Metal cutting is a unique deformation process characterized by large strains, exceptionally high strain rates and few constraints to the deformation. These factors, along with the difficulty of directly measuring the shear angle, make chip formation difficult to model and understand. One technique for skirting the difficulty of post mortem chip measurement is to perform a cutting experiment dynamically in a scanning electron microscope. The performance of the in-situ experiment with full instrumentation allows for component force measurement, orientation measurement (on a round single crystal disk) and a timing device, all superimposed below the deformation on the TV monitor and recorded for future viewing. This allows the sher angle to be directly measured for the screen along with the other needed information.

  18. Online breakage detection of multitooth tools using classifier ensembles for imbalanced data

    NASA Astrophysics Data System (ADS)

    Bustillo, Andrés; Rodríguez, Juan J.

    2014-12-01

    Cutting tool breakage detection is an important task, due to its economic impact on mass production lines in the automobile industry. This task presents a central limitation: real data-sets are extremely imbalanced because breakage occurs in very few cases compared with normal operation of the cutting process. In this paper, we present an analysis of different data-mining techniques applied to the detection of insert breakage in multitooth tools. The analysis applies only one experimental variable: the electrical power consumption of the tool drive. This restriction profiles real industrial conditions more accurately than other physical variables, such as acoustic or vibration signals, which are not so easily measured. Many efforts have been made to design a method that is able to identify breakages with a high degree of reliability within a short period of time. The solution is based on classifier ensembles for imbalanced data-sets. Classifier ensembles are combinations of classifiers, which in many situations are more accurate than individual classifiers. Six different base classifiers are tested: Decision Trees, Rules, Naïve Bayes, Nearest Neighbour, Multilayer Perceptrons and Logistic Regression. Three different balancing strategies are tested with each of the classifier ensembles and compared to their performance with the original data-set: Synthetic Minority Over-Sampling Technique (SMOTE), undersampling and a combination of SMOTE and undersampling. To identify the most suitable data-mining solution, Receiver Operating Characteristics (ROC) graph and Recall-precision graph are generated and discussed. The performance of logistic regression ensembles on the balanced data-set using the combination of SMOTE and undersampling turned out to be the most suitable technique. Finally a comparison using industrial performance measures is presented, which concludes that this technique is also more suited to this industrial problem than the other techniques presented in the bibliography.

  19. Automatic translation of digraph to fault-tree models

    NASA Technical Reports Server (NTRS)

    Iverson, David L.

    1992-01-01

    The author presents a technique for converting digraph models, including those models containing cycles, to a fault-tree format. A computer program which automatically performs this translation using an object-oriented representation of the models has been developed. The fault-trees resulting from translations can be used for fault-tree analysis and diagnosis. Programs to calculate fault-tree and digraph cut sets and perform diagnosis with fault-tree models have also been developed. The digraph to fault-tree translation system has been successfully tested on several digraphs of varying size and complexity. Details of some representative translation problems are presented. Most of the computation performed by the program is dedicated to finding minimal cut sets for digraph nodes in order to break cycles in the digraph. Fault-trees produced by the translator have been successfully used with NASA's Fault-Tree Diagnosis System (FTDS) to produce automated diagnostic systems.

  20. Assessment of wear dependence parameters in complex model of cutting tool wear

    NASA Astrophysics Data System (ADS)

    Antsev, A. V.; Pasko, N. I.; Antseva, N. V.

    2018-03-01

    This paper addresses wear dependence of the generic efficient life period of cutting tools taken as an aggregate of the law of tool wear rate distribution and dependence of parameters of this law's on the cutting mode, factoring in the random factor as exemplified by the complex model of wear. The complex model of wear takes into account the variance of cutting properties within one batch of tools, variance in machinability within one batch of workpieces, and the stochastic nature of the wear process itself. A technique of assessment of wear dependence parameters in a complex model of cutting tool wear is provided. The technique is supported by a numerical example.

  1. Patient-specific instruments in total knee arthroplasty.

    PubMed

    Conteduca, Fabio; Iorio, Raffaele; Mazza, Daniele; Ferretti, Andrea

    2014-02-01

    In recent years, patient-specific instruments (PSI) has been introduced with the aim of reducing the overall costs of the implants, minimising the size and number of instruments required, and also reducing surgery time. The purpose of this study was to perform a review of the current literature, as well as to report about our personal experience, to assess reliability of patient specific instrument system in total knee arthroplasty (TKA). A literature review was conducted of PSI system reviewing articles related to coronal alignment, clinical knee and function scores, cost, patient satisfaction and complications. Studies have reported incidences of coronal alignment ≥3° from neutral in TKAs performed with patient-specific cutting guides ranging from 6% to 31%. PSI seem not to be able to result in the same degree of accuracy as the CAS system, while comparing well with standard manual technique with respect to component positioning and overall lower axis, in particular in the sagittal plane. In cases in which custom-made cutting jigs were used, we recommend performing an accurate control of the alignment before and after any cuts and in any further step of the procedure, in order to avoid possible outliers.

  2. Factors Affecting Microcuttings of Stevia Using a Mist-Chamber Propagation Box

    PubMed Central

    Osman, Mohamad; Samsudin, Nur Syamimi; Faruq, Golam

    2013-01-01

    Stevia rebaudiana Bertoni is a member of Compositae family. Stevia plant has zero calorie content and its leaves are estimated to be 300 times sweeter than sugar. This plant is believed to be the most ideal substitute for sugar and important to assist in medicinal value especially for diabetic patients. In this study, microcutting techniques using a mist-chamber propagation box were used as it was beneficial for propagation of Stevia and gave genetic uniformity to the plant. The effects of different treatments on root stimulation of Stevia in microcuttings technique were evaluated. Treatments studied were different sizes of shoot cuttings, plant growth regulators, lights, and shades. Data logger was used to record the mean value of humidity (>90% RH), light intensity (673–2045 lx), and temperature (28.6–30.1°C) inside the mist-chamber propagation box. From analysis of variance, there were significant differences between varieties and treatments in parameters studied (P < 0.05). For the size of shoot cuttings treatment, 6 nodes cuttings were observed to increase root number. As compared to control, shoot cuttings treated with indole butyric acid (IBA) had better performance regarding root length. Yellow light and 50% shade treatments showed higher root and leaf number and these conditions can be considered as crucial for potential propagation of Stevia. PMID:24470797

  3. Film Editing Handbook; Technique of 16mm Film Cutting.

    ERIC Educational Resources Information Center

    Churchill, Hugh B.

    Designed to help the film student with the complexities of 16mm film cutting, this handbook catalogs the mechanical procedures of both picture and sound cutting and supplies step-by-step explanations of these procedures. Because the handbook was organized so that it could be used while working at the cutting bench, common cutting problems and…

  4. Does gang ripping hold the potential for higher clear cutting yields

    Treesearch

    Hiram Hallock; Pamela Giese

    1980-01-01

    Cutting yields from gang ripping hardwood lumber graded by the National Hardwood Lumber Association standard grades are determined using the technique of mathematical modeling. The lumber used is the same as that in an earlier mathematically modeled determination of cutting yields from traditional rough mill procedures. Mechanical cutting factors such as kerf, cutting...

  5. The UPSF code: a metaprogramming-based high-performance automatically parallelized plasma simulation framework

    NASA Astrophysics Data System (ADS)

    Gao, Xiatian; Wang, Xiaogang; Jiang, Binhao

    2017-10-01

    UPSF (Universal Plasma Simulation Framework) is a new plasma simulation code designed for maximum flexibility by using edge-cutting techniques supported by C++17 standard. Through use of metaprogramming technique, UPSF provides arbitrary dimensional data structures and methods to support various kinds of plasma simulation models, like, Vlasov, particle in cell (PIC), fluid, Fokker-Planck, and their variants and hybrid methods. Through C++ metaprogramming technique, a single code can be used to arbitrary dimensional systems with no loss of performance. UPSF can also automatically parallelize the distributed data structure and accelerate matrix and tensor operations by BLAS. A three-dimensional particle in cell code is developed based on UPSF. Two test cases, Landau damping and Weibel instability for electrostatic and electromagnetic situation respectively, are presented to show the validation and performance of the UPSF code.

  6. Suggested techniques, equipment, and standards for the testing of hand insecticide-spraying equipment

    PubMed Central

    Hall, Lawrence B.

    1955-01-01

    The new demands placed upon application equipment by the introduction of modern insecticides have revealed the deficiencies of this equipment when required for continuous use on a large scale. If adequate equipment is to be produced, specifications must be based not only on basic materials tests but also on “use” tests, in which the conditions of field use are simulated. The author outlines suggested techniques to be followed and standards to be adopted in testing the performance of compression sprayers and allied equipment, with reference to the following features: compression-sprayer tank fatigue; tank impact; pump resistance to bursting; pump resistance to collapse; pump friction; cut-off valve durability; constant-pressure valves; cut-off valve actuation; hose flexure; hose tension and bursting-pressure; hose friction; gaskets, valve faces, and similar non-metallic parts; nozzle-orifice erosion; and nozzle pattern. ImagesFIG. 1FIG. 14FIG. 20 PMID:14364189

  7. Convergence of the Graph Allen-Cahn Scheme

    NASA Astrophysics Data System (ADS)

    Luo, Xiyang; Bertozzi, Andrea L.

    2017-05-01

    The graph Laplacian and the graph cut problem are closely related to Markov random fields, and have many applications in clustering and image segmentation. The diffuse interface model is widely used for modeling in material science, and can also be used as a proxy to total variation minimization. In Bertozzi and Flenner (Multiscale Model Simul 10(3):1090-1118, 2012), an algorithm was developed to generalize the diffuse interface model to graphs to solve the graph cut problem. This work analyzes the conditions for the graph diffuse interface algorithm to converge. Using techniques from numerical PDE and convex optimization, monotonicity in function value and convergence under an a posteriori condition are shown for a class of schemes under a graph-independent stepsize condition. We also generalize our results to incorporate spectral truncation, a common technique used to save computation cost, and also to the case of multiclass classification. Various numerical experiments are done to compare theoretical results with practical performance.

  8. Use of a Piezosurgery Technique to Remove a Deeply Impacted Supernumerary Tooth in the Anterior Maxilla

    PubMed Central

    Sukegawa, Shintaro; Kanno, Takahiro; Kawakami, Kiyokazu; Shibata, Akane; Takahashi, Yuka; Furuki, Yoshihiko

    2015-01-01

    Deeply impacted supernumerary teeth in the anterior maxillary cannot be generally removed by the conventional labial or palatal surgical approach because of the risk of damaging the surrounding soft tissues and the possibility of injuring the roots of adjacent permanent teeth. In piezosurgery, bony tissues are selectively cut, thereby avoiding the soft tissue damage caused by rotary cutting instruments. We report the case of a 15-year-old Japanese boy from whom a deeply impacted supernumerary tooth in the anterior maxillary was safely removed through the floor of the nasal cavity. The surgical extraction was performed without damaging the nasal mucosa or adjacent structures such as the roots of the adjacent permanent teeth. Considering that piezosurgery limits the extent of surgical invasion, this technique can be practiced as a minimally invasive and safe surgical procedure for treating suitably selected cases with a deeply impacted supernumerary tooth. PMID:26779355

  9. Coatings for minimally processed fruits and vegetables

    USDA-ARS?s Scientific Manuscript database

    Fresh-cut fruit and vegetables are gaining increasing popularity and market share. Techniques to enhance stability of fresh cut produce are reviewed. Among these techniques, edibles coatings can provide protection against dehydration, microbial decay and decrease events related to physiological sene...

  10. [Practical skills of harmonic scalpel in laparoscopic gastrointestinal surgery].

    PubMed

    Li, Guo-xin

    2013-10-01

    Harmonic scalpel, one of the most commonly used energy tools, have been recognized as an important revolutionary development in surgical device. Due to its convenience in cutting, coagulating, and dissecting harmonic scalpel has been increasingly used to performed surgery by more and more surgeons. In gastrointestinal surgeries, however, many manipulationssuch as dissecting soft connective tissues off the stomach or colon, isolating and cutting particular vessels, would require proper techniques in handling harmonic scalpels. Thus, based on our experiences of using harmonic scalpel in laparoscopic gastrointestinal surgeries, we summarized a "nine-word tactics", which may be helpful for beginners to use harmonic scalpels in a proper and efficient manner.

  11. [How to make your own custom cutting guides for both mandibular and fibular stair step osteotomies?

    PubMed

    Rem, K; Bosc, R; De Kermadec, H; Hersant, B; Meningaud, J-P

    2017-12-01

    Using tailored cutting guides for osteocutaneous free fibula flap in complex mandibular reconstruction after cancer resection surgery constitutes a substantial improvement. Autonomously conceiving and manufacturing the cutting guides within a plastic surgery department with computer-aided design (CAD) and three-dimensional (3D) printing allows planning more complex osteotomies, such as stair-step osteotomies, in order to achieve more stable internal fixations. For the past three years, we have been producing by ourselves patient-tailored cutting guides using CAD and 3D printing. Osteotomies were virtually planned, making the cutting lines more complex in order to optimize the internal fixation stability. We also printed reconstructed mandible templates and shaped the reconstruction plates on them. We recorded data including manufacturing techniques and surgical outcomes. Eleven consecutive patients were operated on for an oral cavity cancer. For each patient, we planned the fibular and mandibular stair-step osteotomies and we produced tailored cutting guides. In all patients, we achieved to get immediately stable internal fixations and in 10 patients, a complete bone consolidation after 6 months. Autonomously manufacturing surgical cutting guides for mandibular reconstruction by free fibula flap is a significant improvement, regarding ergonomics and precision. Planning stair-step osteotomies to perform complementary internal fixation increases contact surface and congruence between the bone segments, thus improving the reconstructed mandible stability. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  12. Underwater femtosecond laser micromachining of thin nitinol tubes for medical coronary stent manufacture

    NASA Astrophysics Data System (ADS)

    Muhammad, Noorhafiza; Li, Lin

    2012-06-01

    Microprofiling of medical coronary stents has been dominated by the use of Nd:YAG lasers with pulse lengths in the range of a few milliseconds, and material removal is based on the melt ejection with a high-pressure gas. As a result, recast and heat-affected zones are produced, and various post-processing procedures are required to remove these defects. This paper reports a new approach of machining stents in submerged conditions using a 100-fs pulsed laser. A comparison is given of dry and underwater femtosecond laser micromachining techniques of nickel-titanium alloy (nitinol) typically used as the material for coronary stents. The characteristics of laser interactions with the material have been studied. A femtosecond Ti:sapphire laser system (wavelength of 800 nm, pulse duration of 100 fs, repetition rate of 1 kHz) was used to perform the cutting process. It is observed that machining under a thin water film resulted in no presence of heat-affected zone, debris, spatter or recast with fine-cut surface quality. At the optimum parameters, the results obtained with dry cutting showed nearly the same cut surface quality as with cutting under water. However, debris and recast formation still appeared on the dry cut, which is based on material vaporization. Physical processes involved during the cutting process in a thin water film, i.e. bubble formation and shock waves, are discussed.

  13. An experimental assessment on the performance of different lubrication techniques in grinding of Inconel 751.

    PubMed

    Balan, A S S; Vijayaraghavan, L; Krishnamurthy, R; Kuppan, P; Oyyaravelu, R

    2016-09-01

    The application of emulsion for combined heat extraction and lubrication requires continuous monitoring of the quality of emulsion to sustain a desired grinding environment; this is applicable to other grinding fluids as well. Thus to sustain a controlled grinding environment, it is necessary to adopt an effectively lubricated wheel-work interface. The current study was undertaken to assess experimentally the ​ effects of different grinding environments such as dry, minimum quantity lubrication (MQL) and Cryo-MQL on performance, such as grinding force, temperature, surface roughness and chip morphology on Inconel 751, a higher heat resistance material posing thermal problems and wheel loading. The results show that grinding with the combination of both liquid nitrogen (LN2) and MQL lowers temperature, cutting forces, and surface roughness as compared with MQL and dry grinding. Specific cutting energy is widely used as an inverse measure of process efficiency in machining. It is found from the results that specific cutting energy of Cryo-MQL assisted grinding is 50-65% lower than conventional dry grinding. The grindability of Inconel 751 superalloy can be enhanced with Cryo-MQL condition.

  14. Performance evaluation of Titanium nitride coated tool in turning of mild steel

    NASA Astrophysics Data System (ADS)

    Srinivas, B.; Pramod Kumar, G.; Cheepu, Muralimohan; Jagadeesh, N.; kumar, K. Ravi; Haribabu, S.

    2018-03-01

    The growth in demand for bio-gradable materials is opened as a venue for using vegetable oils, coconut oils etc., as alternate to the conventional coolants for machining operations. At present in manufacturing industries the demand for surface quality is increasing rapidly along with dimensional accuracy and geometric tolerances. The present study is influence of cutting parameters on the surface roughness during the turning of mild steel with TiN coated carbide tool using groundnut oil and soluble oil as coolants. The results showed vegetable gave closer surface finish compares with soluble oil. Cutting parameters has been optimized with Taguchi technique. In this paper, the main objective is to optimize the cutting parameters and reduce surface roughness analogous to increase the tool life by apply the coating on the carbide inserts. The cost of the coating is more, but economically efficient than changing the tools frequently. The plots were generated and analysed to find the relationship between them which are confirmed by performing a comparison study between the predicted results and theoretical results.

  15. Research on subsurface defects of potassium dihydrogen phosphate crystals fabricated by single point diamond turning technique

    NASA Astrophysics Data System (ADS)

    Tie, Guipeng; Dai, Yifan; Guan, Chaoliang; Chen, Shaoshan; Song, Bing

    2013-03-01

    Potassium dihydrogen phosphate (KDP) crystals, which are widely used in high-power laser systems, are required to be free of defects on fabricated subsurfaces. The depth of subsurface defects (SSD) of KDP crystals is significantly influenced by the parameters used in the single point diamond turning technique. In this paper, based on the deliquescent magnetorheological finishing technique, the SSD of KDP crystals is observed and the depths under various cutting parameters are detected and discussed. The results indicate that no SSD is generated under small parameters and with the increase of cutting parameters, SSD appears and the depth rises almost linearly. Although the ascending trends of SSD depths caused by cutting depth and feed rate are much alike, the two parameters make different contributions. Taking the same material removal efficiency as a criterion, a large cutting depth generates shallower SSD depth than a large feed rate. Based on the experiment results, an optimized cutting procedure is obtained to generate defect-free surfaces.

  16. Accuracy assessment of surgical planning and three-dimensional-printed patient-specific guides for orthopaedic osteotomies.

    PubMed

    Sys, Gwen; Eykens, Hannelore; Lenaerts, Gerlinde; Shumelinsky, Felix; Robbrecht, Cedric; Poffyn, Bart

    2017-06-01

    This study analyses the accuracy of three-dimensional pre-operative planning and patient-specific guides for orthopaedic osteotomies. To this end, patient-specific guides were compared to the classical freehand method in an experimental setup with saw bones in two phases. In the first phase, the effect of guide design and oscillating versus reciprocating saws was analysed. The difference between target and performed cuts was quantified by the average distance deviation and average angular deviations in the sagittal and coronal planes for the different osteotomies. The results indicated that for one model osteotomy, the use of guides resulted in a more accurate cut when compared to the freehand technique. Reciprocating saws and slot guides improved accuracy in all planes, while oscillating saws and open guides lead to larger deviations from the planned cut. In the second phase, the accuracy of transfer of the planning to the surgical field with slot guides and a reciprocating saw was assessed and compared to the classical planning and freehand cutting method. The pre-operative plan was transferred with high accuracy. Three-dimensional-printed patient-specific guides improve the accuracy of osteotomies and bony resections in an experimental setup compared to conventional freehand methods. The improved accuracy is related to (1) a detailed and qualitative pre-operative plan and (2) an accurate transfer of the planning to the operation room with patient-specific guides by an accurate guidance of the surgical tools to perform the desired cuts.

  17. The effects of the Er:YAG laser on trabecular bone micro-architecture: Comparison with conventional dental drilling by micro-computed tomographic and histological techniques

    PubMed Central

    Zeitouni, Jihad; Clough, Bret; Zeitouni, Suzanne; Saleem, Mohammed; Al Aisami, Kenan; Gregory, Carl

    2017-01-01

    Background: The use of lasers has become increasingly common in the field of medicine and dentistry, and there is a growing need for a deeper understanding of the procedure and its effects on tissue. The aim of this study was to compare the erbium-doped yttrium aluminium garnet (Er:YAG) laser and conventional drilling techniques, by observing the effects on trabecular bone microarchitecture and the extent of thermal and mechanical damage. Methods: Ovine femoral heads were employed to mimic maxillofacial trabecular bone, and cylindrical osteotomies were generated to mimic implant bed preparation. Various laser parameters were tested, as well as a conventional dental drilling technique. The specimens were then subjected to micro-computed tomographic (μCT) histomorphometic analysis and histology. Results: Herein, we demonstrate that mCT measurements of trabecular porosity provide quantitative evidence that laser-mediated cutting preserves the trabecular architecture and reduces thermal and mechanical damage at the margins of the cut. We confirmed these observations with histological studies. In contrast with laser-mediated cutting, conventional drilling resulted in trabecular collapse, reduction of porosity at the margin of the cut and histological signs of thermal damage. Conclusions: This study has demonstrated, for the first time, that mCT and quantification of porosity at the margin of the cut provides a quantitative insight into damage caused by bone cutting techniques. We further show that with laser-mediated cutting, the marrow remains exposed to the margins of the cut, facilitating cellular infiltration and likely accelerating healing. However, with drilling, trabecular collapse and thermal damage is likely to delay healing by restricting the passage of cells to the site of injury and causing localized cell death. PMID:29416849

  18. Performance of single-use and multiuse diamond rotary cutting instruments with turbine and electric handpieces.

    PubMed

    Rotella, Mario; Ercoli, Carlo; Funkenbusch, Paul D; Russell, Scott; Feng, Changyong

    2014-01-01

    As single-use rotary cutting instruments and electric handpieces become more available, the performance of these instruments with electric as compared to turbine handpieces requires evaluation. In addition, if rotary cutting instruments marketed as single-use instruments are used for multiple patients, the effects on their performance of cleaning, sterilization, and repeated use are of interest to the clinician. The purpose of the study was to evaluate how the cleaning, autoclaving, and repeated use of single-use and multiuse rotary cutting instruments, with either a turbine or electric handpiece, affected their performance. The effects on cutting performance of 2 handpieces (turbine and electric), 2 cleaning and sterilization conditions (cleaned and autoclaved versus noncleaned and nonautoclaved), and 6 different diamond rotary cutting instruments (4 single-use and 2 multiuse) during simulated tooth preparations were evaluated by using a 24-treatment condition full-factorial experimental design. A computer-controlled dedicated testing apparatus was used to simulate the cutting procedures, and machinable glass ceramic blocks were used as the cutting substrate for tangential cuts. In addition, for each treatment condition, 8 consecutive cuts, for a total of 192 cuts, were measured to assess the durability of the rotary cutting instruments. A linear mixed model was used to study the effect of instrument type, handpiece, cleaning, and sterilization, as well as the status and number of cuts on the outcome variables. The Tukey honestly significant difference test was used for the post hoc pairwise comparisons (α=.05). Performance, as measured by the rate of advancement, decreased with the repeated use of rotary cutting instruments (P<.001), while cleaning and sterilization procedures improved the average performance of the 8 cuts (P=.002). The electric handpiece showed a greater load than the turbine (P<.001) and a lower rate/load metric, but no differences in the rate of advancement. Significant differences were also detected among the different rotary cutting instruments tested with the Two Striper, which showed the highest cumulative performance of all groups. The repeated use of both single-use and multiuse rotary cutting instruments decreased cutting performance. The use of a cleaning and sterilization procedure between cuts improved the average cutting performance. During a tangential cutting process, although the ease of advancement (rate/load) was greater for the turbine, the electric handpiece did not produce a statistically different cutting rate. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  19. New Technique for the Treatment of Buried Penis in Children.

    PubMed

    Liu, Feng; Lin, Tao; He, Dawei; Wei, Guanghui; Liu, Junhong; Liu, Xing; Hua, Yi; Zhang, Deying; Lu, Peng; Wu, Shengde; Li, Xuliang

    2016-02-01

    To present our treatment experience of buried penis, which has no consensus therapeutic technique for all cases of buried penis, by using a new technique for the repair of this condition, in which the approach is through the ventral penile root. We performed a retrospective review of 153 patients (median age: 6.5 years) who underwent repair of a buried penis between March 2005 and March 2013. The technique involves the creation of a wedge-shaped cut of the ventral penile skin, followed by fixation of the subcutaneous penile skin at the base of the degloved penis to the Buck fascia at the 2- and 10-o'clock positions. The ventral outer preputial skin is split down the midline, and the dorsal inner preputial skin is cut with oblique incision. All patients were followed for an average of 12 months after repair. Other than 2 cases (1.3%) of trapped penis with a ring of scar tissue, which required subsequent excision, there were no complications and the cosmetic appearance was satisfactory. The described ventral penile approach is a simple and effective procedure with good cosmetic outcomes and few complications. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Mathematical Modeling of Thermofrictional Milling Process Using ANSYS WB Software

    NASA Astrophysics Data System (ADS)

    Sherov, K. T.; Sikhimbayev, M. R.; Sherov, A. K.; Donenbayev, B. S.; Rakishev, A. K.; Mazdubai, A. B.; Musayev, M. M.; Abeuova, A. M.

    2017-06-01

    This article presents ANSYS WB-based mathematical modelling of the thermofrictional milling process, which allowed studying the dynamics of thermal and physical processes occurring during the processing. The technique used also allows determination of the optimal cutting conditions of thermofrictional milling for processing various materials, in particular steel 40CN2MA, 30CGSA, 45, 3sp. In our study, from among a number of existing models of cutting fracture, we chose the criterion first proposed by prof. V. L. Kolmogorov. In order to increase the calculations performance, a mathematical model was proposed, that used only two objects: a parallelepiped-shaped workpiece and a cutting insert in the form of a pentagonal prism. In addition, the work takes into account the friction coefficient between a cutting insert and a workpiece taken equal to 0.4 mm. To determine the temperature in the subcontact layer of the workpiece, we introduced the coordinates of nine characteristic points with the same interval in the local coordinate system. As a result, the temperature values were obtained for different materials at the studied points during the cutter speed change. The research results showed the possibility of controlling thermal processes during processing by choosing the optimum cutting modes.

  1. Investigation into the Effects of Textural Properties on Cuttability Performance of a Chisel Tool

    NASA Astrophysics Data System (ADS)

    Tumac, Deniz; Copur, Hanifi; Balci, Cemal; Er, Selman; Avunduk, Emre

    2018-04-01

    The main objective of this study is to investigate the effect of textural properties of stones on cutting performance of a standard chisel tool. Therewithal, the relationships between textural properties and cutting performance parameters and physical and mechanical properties were statistically analyzed. For this purpose, physical and mechanical property tests and mineralogical and petrographic analyses were carried out on eighteen natural stone samples, which can be grouped into three fundamentally different geological origins, i.e., metamorphic, igneous, and sedimentary. Then, texture coefficient analyses were performed on the samples. To determine the cuttability of the stones; the samples were cut with a portable linear cutting machine using a standard chisel tool at different depths of cut in unrelieved (non-interactive) cutting mode. The average and maximum forces (normal and cutting) and specific energy were measured, and the obtained values were correlated with texture coefficient, packing weighting, and grain size. With reference to the relation between depth of cut and cutting performance of the chisel tool for three types of natural stone groups, specific energy decreases with increasing depth of cut, and cutting forces increase in proportion to the depth of cut. The same is observed for the relationship between packing weighting and both of specific energy and cutter forces. On the other hand, specific energy and the forces decrease while grain size increases. Based on the findings of the present study, texture coefficient has strong correlation with specific energy. Generally, the lower depth of cut values in cutting tests shows higher and more reliable correlations with texture coefficient than the increased depth of cut. The results of cutting tests show also that, at a lower depth of cut (less than 1.5 mm), even stronger correlations can be observed between texture coefficient and cutting performance. Experimental studies indicate that cutting performance of chisel tools can be predicted based on texture coefficients of the natural stones.

  2. Multi-scale analytical investigation of fly ash in concrete

    NASA Astrophysics Data System (ADS)

    Aboustait, Mohammed B.

    Much research has been conducted to find an acceptable concrete ingredient that would act as cement replacement. One promising material is fly ash. Fly ash is a by-product from coal-fired power plants. Throughout this document work on the characterization of fly ash structure and composition will be explored. This effort was conducted through a mixture of cutting edge multi-scale analytical X-ray based techniques that use both bulk experimentation and nano/micro analytical techniques. Furtherly, this examination was coupled by performing Physical/Mechanical ASTM based testing on fly ash-enrolled-concrete to examine the effects of fly ash introduction. The most exotic of the cutting edge characterization techniques endorsed in this work uses the Nano-Computed Tomography and the Nano X-ray Fluorescence at Argonne National Laboratory to investigate single fly ash particles. Additional Work on individual fly ash particles was completed by laboratory-based Micro-Computed Tomography and Scanning Electron Microscopy. By combining the results of individual particles and bulk property tests, a compiled perspective is introduced, and accessed to try and make new insights into the reactivity of fly ash within concrete.

  3. Semi-Autonomous Electrosurgery for Tumor Resection Using a Multi-Degree of Freedom Electrosurgical Tool and Visual Servoing*

    PubMed Central

    Opfermann, Justin D.; Leonard, Simon; Decker, Ryan S.; Uebele, Nicholas A.; Bayne, Christopher E.; Joshi, Arjun S.; Krieger, Axel

    2017-01-01

    This paper specifies a surgical robot performing semi-autonomous electrosurgery for tumor resection and evaluates its accuracy using a visual servoing paradigm. We describe the design and integration of a novel, multi-degree of freedom electrosurgical tool for the smart tissue autonomous robot (STAR). Standardized line tests are executed to determine ideal cut parameters in three different types of porcine tissue. STAR is then programmed with the ideal cut setting for porcine tissue and compared against expert surgeons using open and laparoscopic techniques in a line cutting task. We conclude with a proof of concept demonstration using STAR to semi-autonomously resect pseudo-tumors in porcine tissue using visual servoing. When tasked to excise tumors with a consistent 4mm margin, STAR can semi-autonomously dissect tissue with an average margin of 3.67 mm and a standard deviation of 0.89mm. PMID:29503760

  4. Welding And Cutting A Nickel Alloy By Laser

    NASA Technical Reports Server (NTRS)

    Banas, C. M.

    1990-01-01

    Technique effective and energy-efficient. Report describes evaluation of laser welding and cutting of Inconel(R) 718. Notes that electron-beam welding processes developed for In-718, but difficult to use on large or complex structures. Cutting of In-718 by laser fast and produces only narrow kerf. Cut edge requires dressing, to endure fatigue.

  5. Acquisition and retention of laparoscopic skills is different comparing conventional laparoscopic and single-incision laparoscopic surgery: a single-centre, prospective randomized study.

    PubMed

    Ellis, Scott Michael; Varley, Martin; Howell, Stuart; Trochsler, Markus; Maddern, Guy; Hewett, Peter; Runge, Tina; Mees, Soeren Torge

    2016-08-01

    Training in laparoscopic surgery is important not only to acquire and improve skills but also avoid the loss of acquired abilities. The aim of this single-centre, prospective randomized study was to assess skill acquisition of different laparoscopic techniques and identify the point in time when acquired skills deteriorate and training is needed to maintain these skills. Sixty surgical novices underwent laparoscopic surgery (LS) and single-incision laparoscopic surgery (SILS) baseline training (BT) performing two validated tasks (peg transfer, precision cutting). The novices were randomized into three groups and skills retention testing (RT) followed after 8 (group A), 10 (group B) or 12 (group C) weeks accordingly. Task performance was measured in time with time penalties for insufficient task completion. 92 % of the participants completed the BT and managed to complete the task in the required time frame of proficiency. Univariate and multivariate analyses revealed that SILS (P < 0.0001) and precision cutting (P < 0.0001) were significantly more difficult. Males performed significantly better than females (P < 0.005). For LS, a deterioration of skills (comparison of BT vs RT) was not identified; however, for SILS a significant deterioration of skills (adjustment of BT and RT values) was demonstrated for all groups (A-C) (P < 0.05). Our data reveal that complex laparoscopic tasks (cutting) and techniques (SILS) are more difficult to learn and acquired skills more difficult to maintain. Acquired LS skills were maintained for the whole observation period of 12 weeks but SILS skills had begun to deteriorate at 8 weeks. These data show that maintenance of LS and SILS skills is divergent and training curricula need to take these specifics into account.

  6. Effects of Different Cutting Patterns and Experimental Conditions on the Performance of a Conical Drag Tool

    NASA Astrophysics Data System (ADS)

    Copur, Hanifi; Bilgin, Nuh; Balci, Cemal; Tumac, Deniz; Avunduk, Emre

    2017-06-01

    This study aims at determining the effects of single-, double-, and triple-spiral cutting patterns; the effects of tool cutting speeds on the experimental scale; and the effects of the method of yield estimation on cutting performance by performing a set of full-scale linear cutting tests with a conical cutting tool. The average and maximum normal, cutting and side forces; specific energy; yield; and coarseness index are measured and compared in each cutting pattern at a 25-mm line spacing, at varying depths of cut per revolution, and using two cutting speeds on five different rock samples. The results indicate that the optimum specific energy decreases by approximately 25% with an increasing number of spirals from the single- to the double-spiral cutting pattern for the hard rocks, whereas generally little effect was observed for the soft- and medium-strength rocks. The double-spiral cutting pattern appeared to be more effective than the single- or triple-spiral cutting pattern and had an advantage of lower side forces. The tool cutting speed had no apparent effect on the cutting performance. The estimation of the specific energy by the yield based on the theoretical swept area was not significantly different from that estimated by the yield based on the muck weighing, especially for the double- and triple-spiral cutting patterns and with the optimum ratio of line spacing to depth of cut per revolution. This study also demonstrated that the cutterhead and mechanical miner designs, semi-theoretical deterministic computer simulations and empirical performance predictions and optimization models should be based on realistic experimental simulations. Studies should be continued to obtain more reliable results by creating a larger database of laboratory tests and field performance records for mechanical miners using drag tools.

  7. Graph-cut based discrete-valued image reconstruction.

    PubMed

    Tuysuzoglu, Ahmet; Karl, W Clem; Stojanovic, Ivana; Castañòn, David; Ünlü, M Selim

    2015-05-01

    Efficient graph-cut methods have been used with great success for labeling and denoising problems occurring in computer vision. Unfortunately, the presence of linear image mappings has prevented the use of these techniques in most discrete-amplitude image reconstruction problems. In this paper, we develop a graph-cut based framework for the direct solution of discrete amplitude linear image reconstruction problems cast as regularized energy function minimizations. We first analyze the structure of discrete linear inverse problem cost functions to show that the obstacle to the application of graph-cut methods to their solution is the variable mixing caused by the presence of the linear sensing operator. We then propose to use a surrogate energy functional that overcomes the challenges imposed by the sensing operator yet can be utilized efficiently in existing graph-cut frameworks. We use this surrogate energy functional to devise a monotonic iterative algorithm for the solution of discrete valued inverse problems. We first provide experiments using local convolutional operators and show the robustness of the proposed technique to noise and stability to changes in regularization parameter. Then we focus on nonlocal, tomographic examples where we consider limited-angle data problems. We compare our technique with state-of-the-art discrete and continuous image reconstruction techniques. Experiments show that the proposed method outperforms state-of-the-art techniques in challenging scenarios involving discrete valued unknowns.

  8. The influence of cutting-bill requirements on lumber yield using a fractional-factorial design part II, correlation and number of part sizes

    Treesearch

    Urs Buehlmann; D. Earl Kline; Janice K. Wiedenbeck; R., Jr. Noble

    2008-01-01

    Cutting-bill requirements, among other factors, influence the yield obtained when cutting lumber into parts. The first part of this 2-part series described how different cutting-bill part sizes, when added to an existing cutting-bill, affect lumber yield, and quantified these observations. To accomplish this, the study employed linear least squares estimation technique...

  9. Using template/hotwire cutting to demonstrate moldless composite fabrication

    NASA Technical Reports Server (NTRS)

    Coleman, J. Mario

    1990-01-01

    The objective of this experiment is to provide a simple, inexpensive composite fabrication technique which can be easily performed with a minimum of equipment and facilities. This process eliminates expensive female molds and uses only male molds which are easily formed from foam blocks. Once the mold is shaped, it is covered with fiberglass and becomes a structural component of the product.

  10. Supply-chain management: exceeding the customer's expectations.

    PubMed

    Ramsay, B

    2000-10-01

    Driven by increasing competition, manufacturers are desperate to cut costs and are looking for increased efficiency and customer service from their supply chains. E-commerce offers a new model of supply and demand, but many companies do not have the processes in place to support this new model. By implementing the techniques discussed here they can achieve substantial improvements in performance.

  11. Descriptive Analysis of In Vitro Cutting of Swine Mitral Cusps: Comparison of High-Power Laser and Scalpel Blade Cutting Techniques.

    PubMed

    Pinto, Nathali Cordeiro; Pomerantzeff, Pablo Maria Alberto; Deana, Alessandro; Zezell, Denise; Benetti, Carolina; Aiello, Vera Demarchi; Lopes, Luciana Almeida; Jatene, Fabio Biscegli; Chavantes, M Cristina

    2017-02-01

    The most common injury to the heart valve with rheumatic involvement is mitral stenosis, which is the reason for a big number of cardiac operations in Brazil. Commissurotomy is the traditional technique that is still widely used for this condition, although late postoperative restenosis is concerning. This study's purpose was to compare the histological findings of porcine cusp mitral valves treated in vitro with commissurotomy with a scalpel blade to those treated with high-power laser (HPL) cutting, using appropriate staining techniques. Five mitral valves from healthy swine were randomly divided into two groups: Cusp group (G1), cut with a scalpel blade (n = 5), and Cusp group (G2), cut with a laser (n = 5). G2 cusps were treated using a diode laser (λ = 980 nm, power = 9.0 W, time = 12 sec, irradiance = 5625 W/cm 2 , and energy = 108 J). In G1, no histological change was observed in tissue. A hyaline basophilic aspect was focally observed in G2, along with a dark red color on the edges and areas of lower birefringence, when stained with hematoxylin-eosin, Masson's trichrome, and Sirius red. Further, the mean distances from the cutting edge in cusps submitted to laser application and stained with Masson's trichrome and Sirius red were 416.7 and 778.6 μm, respectively, never overcoming 1 mm in length. Thermal changes were unique in the group submitted to HPL and not observed in the cusp group cut with a scalpel blade. The mean distance of the cusps' collagen injury from the cutting edge was less than 1 mm with laser treatment. Additional studies are needed to establish the histological evolution of the laser cutting and to answer whether laser cutting may avoid valvular restenosis better than blade cutting.

  12. The effectiveness of cut-proof glove liners: cut and puncture resistance, dexterity, and sensibility.

    PubMed

    Salkin, J A; Stuchin, S A; Kummer, F J; Reininger, R

    1995-11-01

    Five types of commercial glove liners (within double latex gloves) were compared to single and double latex gloves for cut and puncture resistance and for relative manual dexterity and degree of sensibility. An apparatus was constructed to test glove-pseudofinger constructs in either a cutting or puncture mode. Cutting forces, cutting speed, and type of blade (serrated or scalpel blade) were varied and the time to cut-through measured by an electrical conductivity circuit. Penetration forces were similarly determined with a scalpel blade and a suture needle using a spring scale loading apparatus. Dexterity was measured with an object placement task among a group of orthopedic surgeons. Sensibility was assessed with Semmes-Weinstein monofilaments, two-point discrimination, and vibrametry using standard techniques and rating scales. A subjective evaluation was performed at the end of testing. Time to cut-through for the liners ranged from 2 to 30 seconds for a rapid oscillating scalpel and 4 to 40 seconds for a rapid oscillating serrated knife under minimal loads. When a 1 kg load was added, times to cut-through ranged from 0.4 to 1.0 second. In most cases, the liners were superior to double latex. On average, 100% more force was required to penetrate the liners with a scalpel and 50% more force was required to penetrate the liners with a suture needle compared to double latex. Object placement task times were not significantly liners compared to double latex gloves. Semmes-Weinstein monofilaments, two-point discrimination, and vibrametry showed no difference in sensibility among the various liners and double latex gloves. Subjects felt that the liners were minimally to moderately impairing. An acclimation period may be required for their effective use.

  13. Experimental study of various techniques to protect ice-rich cut slopes.

    DOT National Transportation Integrated Search

    2014-08-01

    Cut slopes are usually required to achieve roadway design grades in the ice-rich permafrost areas in Alaska. However, excavation and exposure of a cut slope destroy the existing thermal balance and result in degradation of ice-rich permafrost. Enviro...

  14. A rapid inoculation technique for assessing pathogenicity of Fusarium oxysporum f. sp. niveum and F. o. melonis on Cucurbits

    USGS Publications Warehouse

    Freeman, S.; Rodriguez, R.J.

    1993-01-01

    A continuous-dip inoculation technique for rapid assessment of pathogenicity of Fusarium oxysporum f. sp. niveum and F. o. melonis was developed. The method, adapted from a similar procedure for determining pathogenicity of Colletotrichum magna (causal agent of anthracnose of cucurbits), involves constant exposure of seedlings and cuttings (seedlings with root systems excised) of watermelon and muskmelon to conidial suspensions contained in small scintillation vials. Disease development in intact seedlings corresponded well to disease responses observed with the standard root-dip inoculation/pot assay. The continuous-dip inoculation technique resulted in rapid disease development, with 50% of watermelon cuttings dying after 4–6 days of exposure to F. o. niveum. A mortality of 30% also was observed in watermelon cuttings exposed to conidia of F. o. melonis, as opposed to only a 0–2.5% mortality in seedlings with intact roots. Disease response was similar with muskmelon seedlings and cuttings continuously dip-inoculated with F. o. melonis isolates. However, no disease symptoms were observed in muskmelon seedlings or cuttings inoculated with F. o. niveum. Four nonpathogenic isolates of F. oxysporum did not cause disease symptoms in either watermelon or muskmelon cuttings and seedlings when assayed by this technique. The proposed method enables a rapid screening of pathogenicity and requires less time, labor, and greenhouse space than the standard root-dip inoculation/pot assay. The reliability of the continuous-dip inoculation technique is limited, however, to exposure of intact seedlings at a concentration of 1 × 106conidia per milliliter; the method is not accurate at this range for excised seedlings.

  15. Design and Test Research on Cutting Blade of Corn Harvester Based on Bionic Principle.

    PubMed

    Tian, Kunpeng; Li, Xianwang; Zhang, Bin; Chen, Qiaomin; Shen, Cheng; Huang, Jicheng

    2017-01-01

    Existing corn harvester cutting blades have problems associated with large cutting resistance, high energy consumption, and poor cut quality. Using bionics principles, a bionic blade was designed by extracting the cutting tooth profile curve of the B. horsfieldi palate. Using a double-blade cutting device testing system, a single stalk cutting performance contrast test for corn stalks obtained at harvest time was carried out. Results show that bionic blades have superior performance, demonstrated by strong cutting ability and good cut quality. Using statistical analysis of two groups of cutting test data, the average cutting force and cutting energy of bionic blades and ordinary blades were obtained as 480.24 N and 551.31 N and 3.91 J and 4.38 J, respectively. Average maximum cutting force and cutting energy consumption for the bionic blade were reduced by 12.89% and 10.73%, respectively. Variance analysis showed that both blade types had a significant effect on maximum cutting energy and cutting energy required to cut a corn stalk. This demonstrates that bionic blades have better cutting force and energy consumption reduction performance than ordinary blades.

  16. Solving Graph Laplacian Systems Through Recursive Bisections and Two-Grid Preconditioning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ponce, Colin; Vassilevski, Panayot S.

    2016-02-18

    We present a parallelizable direct method for computing the solution to graph Laplacian-based linear systems derived from graphs that can be hierarchically bipartitioned with small edge cuts. For a graph of size n with constant-size edge cuts, our method decomposes a graph Laplacian in time O(n log n), and then uses that decomposition to perform a linear solve in time O(n log n). We then use the developed technique to design a preconditioner for graph Laplacians that do not have this property. Finally, we augment this preconditioner with a two-grid method that accounts for much of the preconditioner's weaknesses. Wemore » present an analysis of this method, as well as a general theorem for the condition number of a general class of two-grid support graph-based preconditioners. Numerical experiments illustrate the performance of the studied methods.« less

  17. Noninvasive evaluation system of fractured bone based on speckle interferometry

    NASA Astrophysics Data System (ADS)

    Yamanada, Shinya; Murata, Shigeru; Tanaka, Yohsuke

    2010-11-01

    This paper presents a noninvasive evaluation system of fractured bone based on speckle interferometry using a modified evaluation index for higher performance, and the experiments are carried out to examine the feasibility in evaluating bone fracture healing and the influence of some system parameters on the performance. From experimental results, it is shown that the presence of fractured part of bone and the state of bone fracture healing are successfully estimated by observing fine speckle fringes on the object surface. The proposed evaluation index also can successfully express the difference between the cases with cut and without it. Since most system parameters are found not to affect the performance of the present technique, the present technique is expected to be applied to various patients that have considerable individual variability.

  18. How to Avoid Cast Saw Complications.

    PubMed

    Halanski, Matthew A

    2016-06-01

    As casts are routinely used in pediatric orthopaedics, casts saws are commonly used to remove such casts. Despite being a viewed as the "conservative" and therefore often assumed safest treatment modality, complications associated with the use of casts and cast saws occur. In this manuscript, we review the risk factors associated with cast saw injuries. Cast saw injuries are thermal or abrasive (or both) in nature. Thermal risk factors include: cast saw specifications (including a lack of attached vacuum), use of a dull blade, cutting in a concavity, too thin padding, and overly thick casting materials. Risk factors associated with abrasive injuries include: sharp blades, thin padding, and cutting over boney prominences. Because nearly all clinicians contact the skin with the blade during cast removal, appropriate "in-out technique" is critical. Such technique prevents a hot blade from remaining in contact with the skin for any significant time, diminishing the risk of burn. Similarly, using such technique prevents "dragging the blade" that may pull the skin taught, cutting it. It may be useful to teach proper technique as perforating a cast rather than cutting a cast.

  19. Human Lumbar Ligamentum Flavum Anatomy for Epidural Anesthesia: Reviewing a 3D MR-Based Interactive Model and Postmortem Samples.

    PubMed

    Reina, Miguel A; Lirk, Philipp; Puigdellívol-Sánchez, Anna; Mavar, Marija; Prats-Galino, Alberto

    2016-03-01

    The ligamentum flavum (LF) forms the anatomic basis for the loss-of-resistance technique essential to the performance of epidural anesthesia. However, the LF presents considerable interindividual variability, including the possibility of midline gaps, which may influence the performance of epidural anesthesia. We devise a method to reconstruct the anatomy of the digitally LF based on magnetic resonance images to clarify the exact limits and edges of LF and its different thickness, depending on the area examined, while avoiding destructive methods, as well as the dissection processes. Anatomic cadaveric cross sections enabled us to visually check the definition of the edges along the entire LF and compare them using 3D image reconstruction methods. Reconstruction was performed in images obtained from 7 patients. Images from 1 patient were used as a basis for the 3D spinal anatomy tool. In parallel, axial cuts, 2 to 3 cm thick, were performed in lumbar spines of 4 frozen cadavers. This technique allowed us to identify the entire ligament and its exact limits, while avoiding alterations resulting from cutting processes or from preparation methods. The LF extended between the laminas of adjacent vertebrae at all vertebral levels of the patients examined, but midline gaps are regularly encountered. These anatomical variants were reproduced in a 3D portable document format. The major anatomical features of the LF were reproduced in the 3D model. Details of its structure and variations of thickness in successive sagittal and axial slides could be visualized. Gaps within LF previously studied in cadavers have been identified in our interactive 3D model, which may help to understand their nature, as well as possible implications for epidural techniques.

  20. "Meniscus Sign" to Identify the Lenticule Edge in Small-Incision Lenticule Extraction.

    PubMed

    Titiyal, Jeewan S; Kaur, Manpreet; Brar, Anand S; Falera, Ruchita

    2018-06-01

    To describe our technique of lenticule edge identification in small-incision lenticule extraction using the "meniscus sign" to prevent lenticule misdissection. Femtosecond laser application for small-incision lenticule extraction was performed. A "double ring" was visible, signifying the edge of the cap cut (outer ring) and lenticule cut (inner ring). The anterior and posterior lamellar planes were delineated in 2 different directions. During creation of the posterior lamellar channel, the lenticule edge was slightly pushed away from the surgeon to create a gap between the inner ring (diameter of the lenticule cut) and the lenticule edge. The lenticule edge assumed a frilled wavy appearance, and the meniscus sign was observed as a gap between the lenticule edge and the inner ring. The meniscus-shaped gap served as a landmark to identify the lenticule edge, and the relationship between the frilled lenticule edge and surgical instruments further acted as a guide to identify the correct plane of dissection. This technique was successfully undertaken in 50 eyes of 25 patients. The meniscus sign was observed in all cases, and no case had cap lenticular adhesions. The meniscus sign helps to identify the lenticule edge and correct dissection planes and provides a visual landmark during the entire surgical procedure.

  1. Artificial Intelligence Based Selection of Optimal Cutting Tool and Process Parameters for Effective Turning and Milling Operations

    NASA Astrophysics Data System (ADS)

    Saranya, Kunaparaju; John Rozario Jegaraj, J.; Ramesh Kumar, Katta; Venkateshwara Rao, Ghanta

    2016-06-01

    With the increased trend in automation of modern manufacturing industry, the human intervention in routine, repetitive and data specific activities of manufacturing is greatly reduced. In this paper, an attempt has been made to reduce the human intervention in selection of optimal cutting tool and process parameters for metal cutting applications, using Artificial Intelligence techniques. Generally, the selection of appropriate cutting tool and parameters in metal cutting is carried out by experienced technician/cutting tool expert based on his knowledge base or extensive search from huge cutting tool database. The present proposed approach replaces the existing practice of physical search for tools from the databooks/tool catalogues with intelligent knowledge-based selection system. This system employs artificial intelligence based techniques such as artificial neural networks, fuzzy logic and genetic algorithm for decision making and optimization. This intelligence based optimal tool selection strategy is developed using Mathworks Matlab Version 7.11.0 and implemented. The cutting tool database was obtained from the tool catalogues of different tool manufacturers. This paper discusses in detail, the methodology and strategies employed for selection of appropriate cutting tool and optimization of process parameters based on multi-objective optimization criteria considering material removal rate, tool life and tool cost.

  2. Rock Drilling Performance Evaluation by an Energy Dissipation Based Rock Brittleness Index

    NASA Astrophysics Data System (ADS)

    Munoz, H.; Taheri, A.; Chanda, E. K.

    2016-08-01

    To reliably estimate drilling performance both tool-rock interaction laws along with a proper rock brittleness index are required to be implemented. In this study, the performance of a single polycrystalline diamond compact (PDC) cutter cutting and different drilling methods including PDC rotary drilling, roller-cone rotary drilling and percussive drilling were investigated. To investigate drilling performance by rock strength properties, laboratory PDC cutting tests were performed on different rocks to obtain cutting parameters. In addition, results of laboratory and field drilling on different rocks found elsewhere in literature were used. Laboratory and field cutting and drilling test results were coupled with values of a new rock brittleness index proposed herein and developed based on energy dissipation withdrawn from the complete stress-strain curve in uniaxial compression. To quantify cutting and drilling performance, the intrinsic specific energy in rotary-cutting action, i.e. the energy consumed in pure cutting action, and drilling penetration rate values in percussive action were used. The results show that the new energy-based brittleness index successfully describes the performance of different cutting and drilling methods and therefore is relevant to assess drilling performance for engineering applications.

  3. Improved arthroscopic one-piece excision technique for the treatment of symptomatic discoid medial meniscus.

    PubMed

    Wang, Hong-De; Li, Tong; Gao, Shi-Jun

    2017-10-30

    Discoid medial meniscus is an extremely rare abnormality of the knee. During arthroscopic meniscectomy for symptomatic discoid medial meniscus, it is difficult to remove the posterior portion of the meniscus because of the confined working space within the compartment and the obstruction caused by the anterior cruciate ligament and the tibial intercondylar eminence. To overcome these problems, we describe an improved arthroscopic technique for one-piece excision of symptomatic discoid medial meniscus through three unique portals. Three improved portals were made in the injured knee: a standard anteromedial portal, a central transpatellar tendon portal, and a high anterolateral portal. The anterior side of the discoid medial meniscus was cut 7 mm from the periphery of the meniscus. Next, the anterior portion of the free discoid meniscus fragment was pulled in the anterolateral direction with tension. A curve-shaped cut was made along the longitudinal tear to the posterior horn using basket forceps through the standard anteromedial portal. Then, the anterior portion of the free discoid meniscus was pulled in the anteromedial direction. Pulling the fragment under tension made it easier to cut the posterior side of the discoid meniscus. The posterior side of the discoid meniscus was cut 7 mm from the periphery of the meniscus with straight scissors or basket forceps through the central transpatellar tendon portal. This technique resulted in satisfactory results. Excellent visualization of the posterior part of the discoid medial meniscus was gained during the procedure, and it was easy to cut the posterior part of the discoid medial meniscus. No recurrent symptoms were found. This improved arthroscopic one-piece excision technique for the treatment of symptomatic discoid medial meniscus enables the posterior part of the meniscus to be cut satisfactorily. Moreover, compared with previous techniques, this novel technique causes less formation of foreign bodies and less damage to the anterior cruciate ligament, medial collateral ligament, and cartilage and requires a shorter procedural time.

  4. Safety and efficacy of pancreatic sphincterotomy in chronic pancreatitis.

    PubMed

    Ell, C; Rabenstein, T; Schneider, H T; Ruppert, T; Nicklas, M; Bulling, D

    1998-09-01

    Endoscopic pancreatic sphincterotomy (EPS) is being performed with increasing frequency as a prerequisite to interventional measures in the pancreatic duct. The aim of this study was to evaluate EPS with regard to technique, success, complications, and mortality in patients with chronic pancreatitis. Between January 1989 and September 1996, the results of all consecutive EPSs in patients with chronic pancreatitis were documented in a standardized form. Patients were followed by clinical investigation and blood sample analysis at 4, 24, and 48 hours after EPS. Complications were classified according to commonly accepted criteria. EPS was performed in 118 patients with chronic pancreatitis (men 75%, women 25%, 48+/-10 years). Ninety-four patients (80%) underwent guidewire-assisted EPS, and 24 patients (20%) underwent needle-knife EPS. Seventy-seven EPS procedures (65%) were primarily successful (guidewire EPS: 60 of 94, 64%; needle-knife EPS: 17 of 24, 71%). Additional endoscopic cutting techniques (needle-knife papillotomy, biliary endoscopic sphincterotomy) were required in 41 patients (35%). In total, EPS was successful in 116 patients (98%). The complication rate was 4.2% (4 cases of moderate pancreatitis, 1 severe bleeding, no deaths). All complications were managed nonoperatively. In patients with chronic pancreatitis, EPS with a standard sphincterotome or with a needle-knife offers an effective and reliable approach to the pancreatic duct system. Additional cutting techniques may be necessary in approximately one third of cases before an EPS can be successfully performed. The complication rate of EPS in patients with chronic pancreatitis appears to be lower than the complication rate of biliary sphincterotomy for other indications.

  5. Language study on Spliced Semigraph using Folding techniques

    NASA Astrophysics Data System (ADS)

    Thiagarajan, K.; Padmashree, J.

    2018-04-01

    In this paper, we proposed algorithm to identify cut vertices and cut edges for n-Cut Spliced Semigraph and splicing the n-Cut Spliced Semigraph using cut vertices else cut edges or combination of cut vertex and cut edge and applying sequence of folding to the spliced semigraph to obtain the semigraph quadruple η(S)=(2, 1, 1, 1). We observed that the splicing and folding using both cut vertices and cut edges is applicable only for n-Cut Spliced Semigraph where n > 2. Also, we transformed the spliced semigraph into tree structure and studied the language for the semigraph with n+2 vertices and n+1 semivertices using Depth First Edge Sequence algorithm and obtain the language structure with sequence of alphabet ‘a’ and ‘b’.

  6. Angular analysis of the cyclic impacting oscillations in a robotic grinding process

    NASA Astrophysics Data System (ADS)

    Rafieian, Farzad; Girardin, François; Liu, Zhaoheng; Thomas, Marc; Hazel, Bruce

    2014-02-01

    In a robotic machining process, a light-weight cutter or grinder is usually held by an articulated robot arm. Material removal is achieved by the rotating cutting tool while the robot end effector ensures that the tool follows a programmed trajectory in order to work on complex curved surfaces or to access hard-to-reach areas. One typical application of such process is maintenance and repair work on hydropower equipment. This paper presents an experimental study of the dynamic characteristics of material removal in robotic grinding, which is unlike conventional grinding due to the lower structural stiffness of the tool-holder robot. The objective of the study is to explore the cyclic nature of this mechanical operation to provide the basis for future development of better process control strategies. Grinding tasks that minimize the number of iterations to converge to the target surface can be better planned based on a good understanding and modeling of the cyclic material removal mechanism. A single degree of freedom dynamic analysis of the process suggests that material removal is performed through high-frequency impacts that mainly last for only a small fraction of the grinding disk rotation period. To detect these discrete cutting events in practice, a grinder is equipped with a rotary encoder. The encoder's signal is acquired through the angular sampling technique. A running cyclic synchronous average is applied to the speed signal to remove its non-cyclic events. The measured instantaneous rotational frequency clearly indicates the impacting nature of the process and captures the transient response excited by these cyclic impacts. The technique also locates the angular positions of cutting impacts in revolution cycles. It is thus possible to draw conclusions about the cyclic nature of dynamic changes in impact-cutting behavior when grinding with a flexible robot. The dynamics of the impacting regime and transient responses to impact-cutting excitations captured synchronously using the angular sampling technique provide feedback that can be used to regulate the material removal process. The experimental results also make it possible to correlate the energy required to remove a chip of metal through impacting with the measured drop in angular speed during grinding.

  7. The ‘cut and push’ technique: is it really safe?

    PubMed Central

    Peacock, Oliver; Singh, Rajeev; Cole, Andrew; Speake, William

    2012-01-01

    Percutaneous endoscopic gastrostomy (PEG) feeding is routinely used as an endoscopic and effective method for providing enteral nutrition in those whose oral access has been diminished or lost. One technique for removal of the PEG is cutting the tube at the skin level and allowing the tube and internal flange to pass spontaneously. This is known as the ‘cut and push’ method. Several studies have concluded that the ‘cut and push’ method is a safe and cost-effective method. This case demonstrates a rare cause of small bowel obstruction following the ‘cut and push’ method for PEG replacement, with only a few other cases been reported. This method of removal should be avoided in patients with previous abdominal surgery. It is important that the PEG flange is retrieved endoscopically or an alternative PEG tube (designed to be completely removed through the skin) is used to prevent this complication occurring in such individuals. PMID:22847571

  8. New endoscopic "scissors" to treat Zenker's diverticulum (with video).

    PubMed

    Ramchandani, Mohan; Nageshwar Reddy, D

    2013-10-01

    Zenker's diverticulum (ZD) is a rare disorder but is associated with significant morbidity. Cricopharyngeal (CP) myotomy is the mainstay of treatment, and various flexible endoscopic techniques have been used for division of the septum. However, there is a constant need for improvement in accessories. To evaluate the safety and effectiveness of a new electrocautery endoscopic scissor for CP myotomy in patients with symptomatic ZD. Observational human study. Tertiary-care hospital. This study involved 3 patients with symptomatic ZD. Flexible endoscopic CP myotomy was performed by using a novel scissors-type grasping device. CP myotomy involved 4 steps: (1) opening of the forceps, (2) grasping the muscle fiber, (3) closure of the forceps with application of gentle traction, and (4) dissection of muscle fibers by using cutting current. Intraprocedural bleeding was controlled with the same instrument by grasping vessels and applying coagulation current. Overall feasibility and performance, procedure time to achieve complete CP myotomy. CP myotomy was successfully performed in all patients. Mean procedure time was 10.6 minutes. There were no major adverse events. Minor intraprocedure bleeding occurred in 1 patient. Single arm, limited number of patients. The new instrument has potential advantages in comparison with standard instruments used for CP myotomy. The advantages of this new technique are better control of cutting and hemostatic abilities. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  9. Serial Transmission of Plant Viruses by Cutting During Grafting

    USDA-ARS?s Scientific Manuscript database

    Reciprocal grafts of two tomato (Solanum lycopersicum L.) cultivars were made by hand using commercial grafting techniques. The razor blade used to cut rootstock or scion was first contaminated by making a single cut on tomato plants infected with either tomato spotted wilt virus (TSWV) or tomato m...

  10. Forty-five degree cutting septoplasty.

    PubMed

    Hsiao, Yen-Chang; Chang, Chun-Shin; Chuang, Shiow-Shuh; Kolios, Georgios; Abdelrahman, Mohamed

    2016-01-01

    The crooked nose represents a challenge for rhinoplasty surgeons, and many methods have been proposed for management; however, there is no ideal method for treatment. Accordingly, the 45° cutting septoplasty technique, which involves a 45° cut at the junction of the L-shaped strut and repositioning it to achieve a straight septum is proposed. From October 2010 to September 2014, 43 patients underwent the 45° cutting septoplasty technique. There were 28 men and 15 women, with ages ranging from 20 to 58 years (mean, 33 years). Standardized photographs were obtained at every visit. Established photogrammetric parameters were used to describe the degree of correction: Correction rate = (preoperative total deviation - postoperative residual deviation)/preoperative total deviation × 100% was proposed. The mean follow-up period for all patients was 12.3 months. The mean preoperative deviation was 64.3° and the mean postoperative deviation was 2.7°; the overall correction rate was 95.8%. One patient experienced composite implant deviation two weeks postoperatively and underwent revision rhinoplasty. There were no infections, hematomas or postoperative bleeding. Based on the clinical observation of all patients during the follow-up period, the 45° cutting septoplasty technique was shown to be effective for the treatment of crooked nose.

  11. High precision laser processing of sensitive materials by Microjet

    NASA Astrophysics Data System (ADS)

    Sibailly, Ochelio D.; Wagner, Frank R.; Mayor, Laetitia; Richerzhagen, Bernold

    2003-11-01

    Material laser cutting is well known and widely used in industrial processes, including micro fabrication. An increasing number of applications require nevertheless a superior machining quality than can be achieved using this method. A possibility to increase the cut quality is to opt for the water-jet guided laser technology. In this technique the laser is conducted to the work piece by total internal reflection in a thin stable water-jet, comparable to the core of an optical fiber. The water jet guided laser technique was developed originally in order to reduce the heat damaged zone near the cut, but in fact many other advantages were observed due to the usage of a water-jet instead of an assist gas stream applied in conventional laser cutting. In brief, the advantages are three-fold: the absence of divergence due to light guiding, the efficient melt expulsion, and optimum work piece cooling. In this presentation we will give an overview on several industrial applications of the water-jet guided laser technique. These applications range from the cutting of CBN or ferrite cores to the dicing of thin wafers and the manufacturing of stencils, each illustrates the important impact of the water-jet usage.

  12. Discrimination methods for biological contaminants in fresh-cut lettuce based on VNIR and NIR hyperspectral imaging

    NASA Astrophysics Data System (ADS)

    Mo, Changyeun; Kim, Giyoung; Kim, Moon S.; Lim, Jongguk; Lee, Seung Hyun; Lee, Hong-Seok; Cho, Byoung-Kwan

    2017-09-01

    The rapid detection of biological contaminants such as worms in fresh-cut vegetables is necessary to improve the efficiency of visual inspections carried out by workers. Multispectral imaging algorithms were developed using visible-near-infrared (VNIR) and near-infrared (NIR) hyperspectral imaging (HSI) techniques to detect worms in fresh-cut lettuce. The optimal wavebands that can detect worms in fresh-cut lettuce were investigated for each type of HSI using one-way ANOVA. Worm-detection imaging algorithms for VNIR and NIR imaging exhibited prediction accuracies of 97.00% (RI547/945) and 100.0% (RI1064/1176, SI1064-1176, RSI-I(1064-1173)/1064, and RSI-II(1064-1176)/(1064+1176)), respectively. The two HSI techniques revealed that spectral images with a pixel size of 1 × 1 mm or 2 × 2 mm had the best classification accuracy for worms. The results demonstrate that hyperspectral reflectance imaging techniques have the potential to detect worms in fresh-cut lettuce. Future research relating to this work will focus on a real-time sorting system for lettuce that can simultaneously detect various defects such as browning, worms, and slugs.

  13. Object segmentation using graph cuts and active contours in a pyramidal framework

    NASA Astrophysics Data System (ADS)

    Subudhi, Priyambada; Mukhopadhyay, Susanta

    2018-03-01

    Graph cuts and active contours are two very popular interactive object segmentation techniques in the field of computer vision and image processing. However, both these approaches have their own well-known limitations. Graph cut methods perform efficiently giving global optimal segmentation result for smaller images. However, for larger images, huge graphs need to be constructed which not only takes an unacceptable amount of memory but also increases the time required for segmentation to a great extent. On the other hand, in case of active contours, initial contour selection plays an important role in the accuracy of the segmentation. So a proper selection of initial contour may improve the complexity as well as the accuracy of the result. In this paper, we have tried to combine these two approaches to overcome their above-mentioned drawbacks and develop a fast technique of object segmentation. Here, we have used a pyramidal framework and applied the mincut/maxflow algorithm on the lowest resolution image with the least number of seed points possible which will be very fast due to the smaller size of the image. Then, the obtained segmentation contour is super-sampled and and worked as the initial contour for the next higher resolution image. As the initial contour is very close to the actual contour, so fewer number of iterations will be required for the convergence of the contour. The process is repeated for all the high-resolution images and experimental results show that our approach is faster as well as memory efficient as compare to both graph cut or active contour segmentation alone.

  14. Shoe collar height effect on athletic performance, ankle joint kinematics and kinetics during unanticipated maximum-effort side-cutting performance.

    PubMed

    Lam, Gilbert Wing Kai; Park, Eun Jung; Lee, Ki-Kwang; Cheung, Jason Tak-Man

    2015-01-01

    Side-step cutting manoeuvres comprise the coordination between planting and non-planting legs. Increased shoe collar height is expected to influence ankle biomechanics of both legs and possibly respective cutting performance. This study examined the shoe collar height effect on kinematics and kinetics of planting and non-planting legs during an unanticipated side-step cutting. Fifteen university basketball players performed maximum-effort side-step cutting to the left 45° direction or a straight ahead run in response to a random light signal. Seven successful cutting trials were collected for each condition. Athletic performance, ground reaction force, ankle kinematics and kinetics of both legs were analysed using paired t-tests. Results indicated that high-collar shoes resulted in less ankle inversion and external rotation during initial contact for the planting leg. The high-collar shoes also exhibited a smaller ankle range of motion in the sagittal and transverse planes for both legs, respectively. However, no collar effect was found for ankle moments and performance indicators including cutting performance time, ground contact time, propulsion ground reaction forces and impulses. These findings indicated that high-collar shoes altered ankle positioning and restricted ankle joint freedom movements in both legs, while no negative effect was found for athletic cutting performance.

  15. Characterisation of debris from laser and mechanical cutting of bone.

    PubMed

    Rachmanis, Nikolaos; McGuinness, Garrett B; McGeough, Joseph A

    2014-07-01

    Laser cutting of bones has been proposed as a technology in orthopaedic surgery. In this short study, the laser-bone interaction was examined using a pulsed erbium-doped yttrium aluminium garnet laser and compared to a conventional cutting technique. Microscopic analysis revealed the nature of waste debris and showed higher proportions of finer particles for conventional sagittal sawing compared to laser cutting. © IMechE 2014.

  16. An investigation of the use of discriminant analysis for the classification of blade edge type from cut marks made by metal and bamboo blades.

    PubMed

    Bonney, Heather

    2014-08-01

    Analysis of cut marks in bone is largely limited to two dimensional qualitative description. Development of morphological classification methods using measurements from cut mark cross sections could have multiple uses across palaeoanthropological and archaeological disciplines, where cutting edge types are used to investigate and reconstruct behavioral patterns. An experimental study was undertaken, using porcine bone, to determine the usefulness of discriminant function analysis in classifying cut marks by blade edge type, from a number of measurements taken from their cross-sectional profile. The discriminant analysis correctly classified 86.7% of the experimental cut marks into serrated, non-serrated and bamboo blade types. The technique was then used to investigate a series of cut marks of unknown origin from a collection of trophy skulls from the Torres Strait Islands, to investigate whether they were made by bamboo or metal blades. Nineteen out of twenty of the cut marks investigated were classified as bamboo which supports the non-contemporaneous ethnographic accounts of the knives used for trophy taking and defleshing remains. With further investigation across a variety of blade types, this technique could prove a valuable tool in the interpretation of cut mark evidence from a wide variety of contexts, particularly in forensic anthropology where the requirement for presentation of evidence in a statistical format is becoming increasingly important. © 2014 Wiley Periodicals, Inc.

  17. A theoretical approach to sound propagation and radiation for ducts with suppressors

    NASA Technical Reports Server (NTRS)

    Rice, E. J.; Sawdy, D. T.

    1981-01-01

    The several phenomena involved in theoretical prediction of the far-field sound radiation attenuation from an acoustically lined duct were studied. These include absorption by the suppressor, termination reflections, and far-field radiation. Extensive parametric studies show that the suppressor absorption performance can be correlated with mode cut-off ratio or angle of propagation. The other phenomena can be shown to depend explicitly upon mode cut-off ratio. A complete system can thus be generated which can be used to evaluate aircraft sound suppressors and which can be related to the sound source through the cut-off ratio-acoustic power distribution. Although the method is most fully developed for inlet suppressors, several aft radiated noise phenomena are also discussed. This simplified suppressor design and evaluation method is summarized, the recent improvements in the technique are presented, and areas where further refinement is necessary are discussed. Noise suppressor data from engine experiments are compared with the theoretical calculations.

  18. Large area substrate for surface enhanced Raman spectroscopy (SERS) using glass-drawing technique

    DOEpatents

    Ivanov, Ilia N; Simpson, John T

    2012-06-26

    A method of making a large area substrate comprises drawing a plurality of tubes to form a plurality of drawn tubes, and cutting the plurality of drawn tubes into cut drawn tubes. Each cut drawn tube has a first end and a second end along the longitudinal direction of the respective cut drawn tube. The cut drawn tubes collectively have a predetermined periodicity. The method of making a large area substrate also comprises forming a metal layer on the first ends of the cut drawn tubes to provide a large area substrate.

  19. Method of making large area conformable shape structures for detector/sensor applications using glass drawing technique and postprocessing

    DOEpatents

    Ivanov, Ilia N [Knoxville, TN; Simpson, John T [Clinton, IN

    2012-01-24

    A method of making a large area conformable shape structure comprises drawing a plurality of tubes to form a plurality of drawn tubes, and cutting the plurality of drawn tubes into cut drawn tubes of a predetermined shape. The cut drawn tubes have a first end and a second end along the longitudinal direction of the cut drawn tubes. The method further comprises conforming the first end of the cut drawn tubes into a predetermined curve to form the large area conformable shape structure, wherein the cut drawn tubes contain a material.

  20. Experimental study on internal cooling system in hard turning of HCWCI using CBN tools

    NASA Astrophysics Data System (ADS)

    Ravi, A. M.; Murigendrappa, S. M.

    2018-04-01

    In recent times, hard turning became most emerging technique in manufacturing processes, especially to cut high hard materials like high chrome white cast iron (HCWCI). Use of Cubic boron nitride (CBN), pCBN and Carbide tools are most appropriate to shear the metals but are uneconomical. Since hard turning carried out in dry condition, lowering the tool wear by minimizing tool temperature is the only solution. Study reveals, no effective cooling systems are available so for in order to enhance the tool life of the cutting tools and to improve machinability characteristics. The detrimental effect of cutting parameters on cutting temperature is generally controlled by proper selections. The objective of this paper is to develop a new cooling system to control tool tip temperature, thereby minimizing the cutting forces and the tool wear rates. The materials chosen for this work was HCWCI and cutting tools are CBN inserts. Intricate cavities were made on the periphery of the tool holder for easy flow of cold water. Taguchi techniques were adopted to carry out the experimentations. The experimental results confirm considerable reduction in the cutting forces and tool wear rates.

  1. Laser processing of phenolic wood substitutes

    NASA Astrophysics Data System (ADS)

    Quintero, F.; Riveiro, A.; Lusquiños, F.; Penide, J.; Arias-González, F.; del Val, J.; Comesaña, R.; Boutinguiza, M.; Pou, J.

    2013-11-01

    Phenolic resin boards (PRB) are wood substitutes that comprises of a thick core exclusively made of phenolic resin covered by a thin sheet of melamine resin imitating the aspect of natural wood. The use of these materials in furniture and in construction industry has proliferated during last years. Boards made of phenolic resins are dense, hard and very difficult to cut using band saws, disc saws, or milling cutters. Nevertheless, these difficulties can be overcome by means of laser cutting, which is one of the most firmly established techniques for separating materials. This is due to the great advantages of this technique over traditional cutting methods, such as its versatility and flexibility that allow effective cutting. Nevertheless, charring of the cut edge surface caused by laser induced thermal degradation degrades the cut quality under non-optimized processing conditions. In this research work the viability and quality of CO2 laser cutting process of phenolic resin boards and wood particleboard panels has been evaluated. The present work validates the cut of phenolic resin boards by CO2 lasers using a high laser power and elevated cutting speeds. Moreover, this process involves a serious health hazard since the combustion and decomposition of wood may produce fumes and vapors, which can be toxic and carcinogenic according to the International Chemical Safety Cards (ICSC). Therefore, this work was complemented by the assessment of the potential toxicity of the condensed residues formed on the cut edges, and assessment of the chemistry of the generated fumes by chromatography.

  2. Clonal propagation on Eucalyptus by cuttings in France

    Treesearch

    H. Chaperon

    1983-01-01

    A.FO.CEL has developed a technique for mass propagation by cuttings of Eucalyptus in France. This technique is described from the selection of the ortet to the mass propagation of the clone for afforestation: the first stage is the mobilization of the ortet, the second stage is called pre-propagation which includes rejuvenating and rooting conditioning, the third stage...

  3. Secondary Maxillary and Orbital Floor Reconstruction With a Free Scapular Flap Using Cutting and Fixation Guides Created by Computer-Aided Design/Computer-Aided Manufacturing.

    PubMed

    Morita, Daiki; Numajiri, Toshiaki; Tsujiko, Shoko; Nakamura, Hiroko; Yamochi, Ryo; Sowa, Yoshihiro; Yasuda, Makoto; Hirano, Shigeru

    2017-11-01

    Computer-aided design/computer-aided manufacturing (CAD/CAM) guides are now widely used in maxillofacial reconstruction. However, there are few reports of CAD/CAM guides being used for scapular flaps. The authors performed the secondary maxillary and orbital floor reconstruction using a free latissimus dorsi muscle, cutaneous tissue, and scapular flap designed using CAD/CAM techniques in a 72-year-old man who had undergone partial maxillectomy four years previously. The patient had diplopia, the vertical dystopia of eye position, and a large oral-nasal-cutaneous fistula. After the operation, the authors confirmed that the deviation between the postoperative and preoperative planning three-dimensional images was less than 2 mm. Because scapular guides require 3 cutting surfaces, the shape of the scapular guide is more complex than that of a conventional fibular guide. In orbital floor reconstruction, the use of a CAM technique such as that used to manufacture the authors' fixation guide is as necessary for accurate, safe, and easy reconstruction as is preoperative CAD planning. The production of a fixation guide as well as a cutting guide is particularly useful because it is difficult to determine the angle for reconstructing the orbital floor by freehand techniques. In this case, the orbital floor was reconstructed based on a mirror image of the healthy side to avoid overcompression of the orbital tissue. Although the patient's vertical dystopia of eye position was improved, diplopia was not improved because, for greater safety, the authors did not plan overcorrection of the orbital volume.

  4. Ground penetrating radar for asparagus detection

    NASA Astrophysics Data System (ADS)

    Seyfried, Daniel; Schoebel, Joerg

    2016-03-01

    Ground penetrating radar is a promising technique for detection of buried objects. Recently, radar has more and more been identified to provide benefits for a plurality of applications, where it can increase efficiency of operation. One of these fields is the industrial automatic harvesting process of asparagus, which is performed so far by cutting the soil ridge at a certain height including all the asparagus spears and subsequently sieving the latter out of the soil. However, the height where the soil is cut is a critical parameter, since a wrong value leads to either damage of the roots of the asparagus plants or to a reduced crop yield as a consequence of too much biomass remaining in the soil. In this paper we present a new approach which utilizes ground penetrating radar for non-invasive sensing in order to obtain information on the optimal height for cutting the soil. Hence, asparagus spears of maximal length can be obtained, while keeping the roots at the same time undamaged. We describe our radar system as well as the subsequent digital signal processing steps utilized for extracting the information required from the recorded radar data, which then can be fed into some harvesting unit for setting up the optimal cutting height.

  5. CUTSETS - MINIMAL CUT SET CALCULATION FOR DIGRAPH AND FAULT TREE RELIABILITY MODELS

    NASA Technical Reports Server (NTRS)

    Iverson, D. L.

    1994-01-01

    Fault tree and digraph models are frequently used for system failure analysis. Both type of models represent a failure space view of the system using AND and OR nodes in a directed graph structure. Fault trees must have a tree structure and do not allow cycles or loops in the graph. Digraphs allow any pattern of interconnection between loops in the graphs. A common operation performed on digraph and fault tree models is the calculation of minimal cut sets. A cut set is a set of basic failures that could cause a given target failure event to occur. A minimal cut set for a target event node in a fault tree or digraph is any cut set for the node with the property that if any one of the failures in the set is removed, the occurrence of the other failures in the set will not cause the target failure event. CUTSETS will identify all the minimal cut sets for a given node. The CUTSETS package contains programs that solve for minimal cut sets of fault trees and digraphs using object-oriented programming techniques. These cut set codes can be used to solve graph models for reliability analysis and identify potential single point failures in a modeled system. The fault tree minimal cut set code reads in a fault tree model input file with each node listed in a text format. In the input file the user specifies a top node of the fault tree and a maximum cut set size to be calculated. CUTSETS will find minimal sets of basic events which would cause the failure at the output of a given fault tree gate. The program can find all the minimal cut sets of a node, or minimal cut sets up to a specified size. The algorithm performs a recursive top down parse of the fault tree, starting at the specified top node, and combines the cut sets of each child node into sets of basic event failures that would cause the failure event at the output of that gate. Minimal cut set solutions can be found for all nodes in the fault tree or just for the top node. The digraph cut set code uses the same techniques as the fault tree cut set code, except it includes all upstream digraph nodes in the cut sets for a given node and checks for cycles in the digraph during the solution process. CUTSETS solves for specified nodes and will not automatically solve for all upstream digraph nodes. The cut sets will be output as a text file. CUTSETS includes a utility program that will convert the popular COD format digraph model description files into text input files suitable for use with the CUTSETS programs. FEAT (MSC-21873) and FIRM (MSC-21860) available from COSMIC are examples of programs that produce COD format digraph model description files that may be converted for use with the CUTSETS programs. CUTSETS is written in C-language to be machine independent. It has been successfully implemented on a Sun running SunOS, a DECstation running ULTRIX, a Macintosh running System 7, and a DEC VAX running VMS. The RAM requirement varies with the size of the models. CUTSETS is available in UNIX tar format on a .25 inch streaming magnetic tape cartridge (standard distribution) or on a 3.5 inch diskette. It is also available on a 3.5 inch Macintosh format diskette or on a 9-track 1600 BPI magnetic tape in DEC VAX FILES-11 format. Sample input and sample output are provided on the distribution medium. An electronic copy of the documentation in Macintosh Microsoft Word format is included on the distribution medium. Sun and SunOS are trademarks of Sun Microsystems, Inc. DEC, DeCstation, ULTRIX, VAX, and VMS are trademarks of Digital Equipment Corporation. UNIX is a registered trademark of AT&T Bell Laboratories. Macintosh is a registered trademark of Apple Computer, Inc.

  6. JAG Tearing Technique with Radiofrequency Guide Wire for Aortic Fenestration in Thoracic Endovascular Aneurysm Repair

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ricci, Carmelo; Ceccherini, Claudio, E-mail: claudiocec@hotmail.it; Leonini, Sara

    An innovative approach, the JAG tearing technique, was performed during thoracic endovascular aneurysm repair in a patient with previous surgical replacement of the ascending aorta with a residual uncomplicated type B aortic dissection who developed an aneurysm of the descending thoracic aorta with its lumen divided in two parts by an intimal flap. The proximal landing zone was suitable to place a thoracic stent graft. The distal landing zone was created by cutting the intimal flap in the distal third of the descending thoracic aorta with a radiofrequency guide wire and intravascular ultrasound catheter.

  7. [Improvement of magnetic resonance phase unwrapping method based on Goldstein Branch-cut algorithm].

    PubMed

    Guo, Lin; Kang, Lili; Wang, Dandan

    2013-02-01

    The phase information of magnetic resonance (MR) phase image can be used in many MR imaging techniques, but phase wrapping of the images often results in inaccurate phase information and phase unwrapping is essential for MR imaging techniques. In this paper we analyze the causes of errors in phase unwrapping with the commonly used Goldstein Brunch-cut algorithm and propose an improved algorithm. During the unwrapping process, masking, filtering, dipole- remover preprocessor, and the Prim algorithm of the minimum spanning tree were introduced to optimize the residues essential for the Goldstein Brunch-cut algorithm. Experimental results showed that the residues, branch-cuts and continuous unwrapped phase surface were efficiently reduced and the quality of MR phase images was obviously improved with the proposed method.

  8. Discrimination methods of biological contamination on fresh-cut lettuce based on VNIR and NIR hyperspectral imaging

    USDA-ARS?s Scientific Manuscript database

    Multispectral imaging algorithms were developed using visible-near-infrared (VNIR) and near-infrared (NIR) hyperspectral imaging (HSI) techniques to detect worms on fresh-cut lettuce. The optimal wavebands that detect worm on fresh-cut lettuce for each type of HSI were investigated using the one-way...

  9. Development of low-cost silicon crystal growth techniques for terrestrial photovoltaic solar energy conversion

    NASA Technical Reports Server (NTRS)

    Zoutendyk, J. A.

    1976-01-01

    Because of the growing need for new sources of electrical energy, photovoltaic solar energy conversion is being developed. Photovoltaic devices are now being produced mainly from silicon wafers obtained from the slicing and polishing of cylindrically shaped single crystal ingots. Inherently high-cost processes now being used must either be eliminated or modified to provide low-cost crystalline silicon. Basic to this pursuit is the development of new or modified methods of crystal growth and, if necessary, crystal cutting. If silicon could be grown in a form requiring no cutting, a significant cost saving would potentially be realized. Therefore, several techniques for growth in the form of ribbons or sheets are being explored. In addition, novel techniques for low-cost ingot growth and cutting are under investigation.

  10. Monosomy 3 by FISH in uveal melanoma: variability in techniques and results.

    PubMed

    Aronow, Mary; Sun, Yang; Saunthararajah, Yogen; Biscotti, Charles; Tubbs, Raymond; Triozzi, Pierre; Singh, Arun D

    2012-09-01

    Tumor monosomy 3 confers a poor prognosis in patients with uveal melanoma. We critically review the techniques used for fluorescence in situ hybridization (FISH) detection of monosomy 3 in order to assess variability in practice patterns and to explain differences in results. Significant variability that has likely affected reported results was found in tissue sampling methods, selection of FISH probes, number of cells counted, and the cut-off point used to determine monosomy 3 status. Clinical parameters and specific techniques employed to report FISH results should be specified so as to allow meta-analysis of published studies. FISH-based detection of monosomy 3 in uveal melanoma has not been performed in a standardized manner, which limits conclusions regarding its clinical utility. FISH is a widely available, versatile technology, and when performed optimally has the potential to be a valuable tool for determining the prognosis of uveal melanoma. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. The use of water-jetting technology in prostheses revision surgery-first results of parameter studies on bone and bone cement.

    PubMed

    Honl, M; Rentzsch, R; Müller, G; Brandt, C; Bluhm, A; Hille, E; Louis, H; Morlock, M

    2000-01-01

    Water-jet cutting techniques have been used in industrial applications for many different materials. Recently these techniques have been developed into a revolutionary cutting tool for soft tissues in visceral surgery. The present study investigates the usage of this cutting technology for the revision surgery of endoprostheses. In the first part of the study, samples of bovine bone and acrylic bone cement (PMMA) were cut using an industrial jet cutting device with pure water. Below 400 bar, only PMMA was cut; above 400 bar, bone was also cut, but only pressures above 800 bar resulted in clinically useful rates of material removal (cut depth 2. 4 mm at 10 mm/min traverse speed). In the second part of the study, the effect of adding biocompatible abrasives to the water in order to reduce the required pressure was investigated, resulting in a significantly higher removal of material. At 600 bar, PMMA was cut 5. 2 mm deep with plain water and 15.2 mm deep with added abrasives. The quality of the cuts was increased by the abrasive. Though there was no clear selectivity between bone and PMMA any more, the rate of material removal at similar pressures was significantly higher for PMMA than for bone (600 bar: 1.6 mm cut depth for bone samples, 15.2 mm for PMMA). The measured cut depths with either method were not influenced by a change of the cutting direction with respect to the main direction of the osteons in the bone. However, a reduction of the jet surface angle (90 degrees to 23 degrees ) resulted for bone in a significantly lower cut depth at 600 bar (plain water: 0.62 mm vs. 0.06 mm; abrasive: 1.61 mm vs. 0.60 mm). The laboratory experiments indicate that abrasive water jets may be suitable for cutting biomaterials like bone and bone cement. Copyright 2000 John Wiley & Sons, Inc.

  12. Productive potential of cassava plants (Manihot esculenta Crantz) propagated by leaf buds.

    PubMed

    Neves, Reizaluamar J; Diniz, Rafael P; Oliveira, Eder J DE

    2018-04-23

    New techniques of rapid multiplication of cassava (Manihot esculenta Crantz) have been developed, requiring technical support for large-scale use. This work main to evaluate the agronomic performance of plantlets obtained by leaf buds technique against stem cuttings in the field conditions. The work was conducted using the randomized block design in a factorial scheme with 3 varieties (BRS Kiriris, 98150-06, 9624-09) × 4 origins of the plantlets (conventional - stem cuttings of 20 cm length, leaf buds of the upper, middle and inferior stem part) × 2 agrochemicals (control and treated). There was a remarkable decrease in some agronomic traits that ranged from 23% (number of branches) to 62% (shoot weight) when using leaf buds plantlets. The treatment of plantlets with agrochemicals promoted significant increases in all traits, ranging from 26% (number of roots per plant) to 46% (shoot weight). The plantlets originating from leaf buds of the upper and middle parts were able to generate stem-like plants similar to stem-derived ones. Despite its lower agronomic performance under field conditions, multiplication by leaf buds may generate five times the number of propagules in comparison with the conventional multiplication, and therefore it could be a viable alternative for rapid cassava multiplication.

  13. Improved Concrete Cutting and Excavation Capabilities for Crater Repair Phase 2

    DTIC Science & Technology

    2015-05-01

    production rate and ease of execution. The current ADR techniques, tactics, and procedures (TTPs) indicate cutting of pavement around a small crater...demonstrations and evaluations were used to create the techniques, tactics, and procedures (TTPs) manual describing the processes and requirements of...was more difficult when dowels were present. In general, the OUA demonstration validated that the new materials, equipment, and procedures were

  14. Reliable change of the sensory organization test.

    PubMed

    Broglio, Steven P; Ferrara, Michael S; Sopiarz, Kay; Kelly, Michael S

    2008-03-01

    To establish the sensitivity and specificity of the NeuroCom Sensory Organization Test (SOT) and provide practitioners with cut-scores for clinical decision making using estimates of reliable change. Retrospective cohort study. Research laboratory. Healthy (n = 66) and concussed (n = 63) young adult participants. Postural control assessments on the NeuroCom SOT were completed twice (baseline and follow-up) for both groups. Postconcussion assessments were administered within 24 hours of injury diagnosis. The reliable change technique was used to calculated cut-scores for each SOT variable (composite balance; somatosensory, visual, and vestibular ratios) at the 95%, 90%, 85%, 80%, 75%, and 70% confidence interval levels. When cut-scores were applied to the post-concussion evaluations, sensitivity and specificity varied with SOT variable and confidence interval. An evaluation for change on one or more SOT variable resulted in the highest combined sensitivity (57%) and specificity (80%) at the 75% confidence interval. Use of reliable change scores to detect significant changes in performance on the SOT resulted in decreased sensitivity and improved specificity compared to a previous report. These findings indicate that some concussed athletes may not show large changes in postconcussion postural control and this postural control evaluation should not be used in exclusion of other assessment techniques. The postural control assessment should be combined with other evaluative measures to gain the highest sensitivity to concussive injuries.

  15. Alveolar Bone Housing- A Modified Wilkodontics Approach- A Case Report

    PubMed Central

    Sanjay, Kothamachu; Bhongade, ML; Shrivastav, Sunita

    2016-01-01

    Accelerated orthodontic treatment is the need of the hour in current scenario as the conventional orthodontics is time taking. Corticotomy assisted orthodontics have been used for years to reduce the treatment duration by reducing the resistance provided by alveolar bone housing. This case report describes the orthodontic treatment combined with the modification in conventional wilkodontic technique in a patient to accelerate tooth movement and shorten the treatment time with an anterior open bite and flared and spaced upper and lower incisors. Firstly plaque control was achieved with supra and subgingival scaling. A modified approach using periodontal access flap followed by vertical bone cuts in the cortical bone from the crest of the alveolar bone margin to 2mm-3mm below the apices of all the anterior teeth extending from upper left canine to upper right canine were performed. These vertical cuts were joined by horizontal cuts apically and flap repositioned. An MBT 0.018 inch appliance was bonded. Orthodontic therapy proceeded with frequent activation of the appliances to retract the incisors every two weeks. The total treatment time was four and half months with active period of two months and no adverse effects were observed at the end of active treatment. The modified decortication technique reduced the treatment time to a considerable extent. The interdental spacing closed and optimum overjet and overbite was achieved. PMID:27656577

  16. Laser vs bur for bone cutting in impacted mandibular third molar surgery: A randomized controlled trial.

    PubMed

    Passi, Deepak; Pal, Uma Shankar; Mohammad, Shadab; Singh, Rakesh Kumar; Mehrotra, Divya; Singh, Geeta; Kumar, Manoj; Chellappa, Arul A L; Gupta, Chandan

    2013-01-01

    The aim of this study was to assess the feasibility of Er: YAG laser in bone cutting for removal of impacted lower third molar teeth and compare its outcomes with that of surgical bur. The study comprised 40 subjects requiring removal of impacted mandibular third molar, randomly categorized into two equal groups of 20 each, who had their impacted third molar removed either using Er: YAG laser or surgical bur as per their group, using standard methodology of extraction of impacted teeth. Clinical parameters like pain, bleeding, time taken for bone cutting, postoperative swelling, trismus, wound healing and complications were compared for both groups. Clinical parameters like pain, bleeding and swelling were lower in laser group than bur group, although the difference was statistically not significant. However, postoperative swelling showed significant difference in the two groups. Laser group required almost double the time taken for bone cutting with bur. Trismus persisted for a longer period in laser group. Wound healing and complications were assessed clinically and there was no significant difference in both the groups. Based on the results of our study, the possibility of bone cutting using lasers is pursued, the osteotomy is easily performed and the technique is better suited to minimally invasive surgical procedures. The use of Er: YAG laser may be considered as an alternative tool to surgical bur, specially in anxious patients.

  17. Augmented Endoscopic Images Overlaying Shape Changes in Bone Cutting Procedures.

    PubMed

    Nakao, Megumi; Endo, Shota; Nakao, Shinichi; Yoshida, Munehito; Matsuda, Tetsuya

    2016-01-01

    In microendoscopic discectomy for spinal disorders, bone cutting procedures are performed in tight spaces while observing a small portion of the target structures. Although optical tracking systems are able to measure the tip of the surgical tool during surgery, the poor shape information available during surgery makes accurate cutting difficult, even if preoperative computed tomography and magnetic resonance images are used for reference. Shape estimation and visualization of the target structures are essential for accurate cutting. However, time-varying shape changes during cutting procedures are still challenging issues for intraoperative navigation. This paper introduces a concept of endoscopic image augmentation that overlays shape changes to support bone cutting procedures. This framework handles the history of the location of the measured drill tip as a volume label and visualizes the remains to be cut overlaid on the endoscopic image in real time. A cutting experiment was performed with volunteers, and the feasibility of this concept was examined using a clinical navigation system. The efficacy of the cutting aid was evaluated with respect to the shape similarity, total moved distance of a cutting tool, and required cutting time. The results of the experiments showed that cutting performance was significantly improved by the proposed framework.

  18. Environmental performance, mechanical and microstructure analysis of concrete containing oil-based drilling cuttings pyrolysis residues of shale gas.

    PubMed

    Wang, Chao-Qiang; Lin, Xiao-Yan; He, Ming; Wang, Dan; Zhang, Si-Lan

    2017-09-15

    The overall objective of this research project is to investigate the feasibility of incorporating oil-based drilling cuttings pyrolysis residues (ODPR) and fly ash serve as replacements for fine aggregates and cementitious materials in concrete. Mechanical and physical properties, detailed environmental performances, and microstructure analysis were carried out. Meanwhile, the early hydration process and hydrated products of ODPR concrete were analyzed with X-ray diffraction (XRD), Fourier transform infrared (FT-IR), scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX). The results indicated that ODPR could not be categorize into hazardous wastes. ODPR had specific pozzolanic characteristic and the use of ODPR had certain influence on slump and compressive strength of concrete. The best workability and optimal compressive strength were achieved with the help of 35% ODPR. Environmental performance tests came to conclusion that ODPR as recycled aggregates and admixture for the preparation of concrete, from the technique perspective, were the substance of mere environmental contamination. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Automated segmentation of synchrotron radiation micro-computed tomography biomedical images using Graph Cuts and neural networks

    NASA Astrophysics Data System (ADS)

    Alvarenga de Moura Meneses, Anderson; Giusti, Alessandro; de Almeida, André Pereira; Parreira Nogueira, Liebert; Braz, Delson; Cely Barroso, Regina; deAlmeida, Carlos Eduardo

    2011-12-01

    Synchrotron Radiation (SR) X-ray micro-Computed Tomography (μCT) enables magnified images to be used as a non-invasive and non-destructive technique with a high space resolution for the qualitative and quantitative analyses of biomedical samples. The research on applications of segmentation algorithms to SR-μCT is an open problem, due to the interesting and well-known characteristics of SR images for visualization, such as the high resolution and the phase contrast effect. In this article, we describe and assess the application of the Energy Minimization via Graph Cuts (EMvGC) algorithm for the segmentation of SR-μCT biomedical images acquired at the Synchrotron Radiation for MEdical Physics (SYRMEP) beam line at the Elettra Laboratory (Trieste, Italy). We also propose a method using EMvGC with Artificial Neural Networks (EMANNs) for correcting misclassifications due to intensity variation of phase contrast, which are important effects and sometimes indispensable in certain biomedical applications, although they impair the segmentation provided by conventional techniques. Results demonstrate considerable success in the segmentation of SR-μCT biomedical images, with average Dice Similarity Coefficient 99.88% for bony tissue in Wistar Rats rib samples (EMvGC), as well as 98.95% and 98.02% for scans of Rhodnius prolixus insect samples (Chagas's disease vector) with EMANNs, in relation to manual segmentation. The techniques EMvGC and EMANNs cope with the task of performing segmentation in images with the intensity variation due to phase contrast effects, presenting a superior performance in comparison to conventional segmentation techniques based on thresholding and linear/nonlinear image filtering, which is also discussed in the present article.

  20. GSRP/David Marshall: Fully Automated Cartesian Grid CFD Application for MDO in High Speed Flows

    NASA Technical Reports Server (NTRS)

    2003-01-01

    With the renewed interest in Cartesian gridding methodologies for the ease and speed of gridding complex geometries in addition to the simplicity of the control volumes used in the computations, it has become important to investigate ways of extending the existing Cartesian grid solver functionalities. This includes developing methods of modeling the viscous effects in order to utilize Cartesian grids solvers for accurate drag predictions and addressing the issues related to the distributed memory parallelization of Cartesian solvers. This research presents advances in two areas of interest in Cartesian grid solvers, viscous effects modeling and MPI parallelization. The development of viscous effects modeling using solely Cartesian grids has been hampered by the widely varying control volume sizes associated with the mesh refinement and the cut cells associated with the solid surface. This problem is being addressed by using physically based modeling techniques to update the state vectors of the cut cells and removing them from the finite volume integration scheme. This work is performed on a new Cartesian grid solver, NASCART-GT, with modifications to its cut cell functionality. The development of MPI parallelization addresses issues associated with utilizing Cartesian solvers on distributed memory parallel environments. This work is performed on an existing Cartesian grid solver, CART3D, with modifications to its parallelization methodology.

  1. CO2 laser cutting of ultra thin (75 μm) glass based rigid optical solar reflector (OSR) for spacecraft application

    NASA Astrophysics Data System (ADS)

    Mishra, Shubham; Sridhara, N.; Mitra, Avijit; Yougandar, B.; Dash, Sarat Kumar; Agarwal, Sanjay; Dey, Arjun

    2017-03-01

    Present study reports for the first time laser cutting of multilayered coatings on both side of ultra thin (i.e., 75 μm) glass substrate based rigid optical solar reflector (OSR) for spacecraft thermal control application. The optimization of cutting parameters was carried out as a function of laser power, cutting speed and number of cutting passes and their effect on cutting edge quality. Systematic and in-detail microstructural characterizations were carried out by optical and scanning electron microscopy techniques to study the laser affected zone and cutting edge quality. Sheet resistance and water contact angle experiments were also conducted locally both prior and after laser cut to investigate the changes of electrical and surface properties, if any.

  2. Experimental Evaluation and Optimization of Flank Wear During Turning of AISI 4340 Steel with Coated Carbide Inserts Using Different Cutting Fluids

    NASA Astrophysics Data System (ADS)

    Lawal, S. A.; Choudhury, I. A.; Nukman, Y.

    2015-01-01

    The understanding of cutting fluids performance in turning process is very important in order to improve the efficiency of the process. This efficiency can be determined based on certain process parameters such as flank wear, cutting forces developed, temperature developed at the tool chip interface, surface roughness on the work piece, etc. In this study, the objective is to determine the influence of cutting fluids on flank wear during turning of AISI 4340 with coated carbide inserts. The performances of three types of cutting fluids were compared using Taguchi experimental method. The results show that palm kernel oil based cutting fluids performed better than the other two cutting fluids in reducing flank wear. Mathematical models for cutting parameters such as cutting speed, feed rate, depth of cut and cutting fluids were obtained from regression analysis using MINITAB 14 software to predict flank wear. Experiments were conducted based on the optimized values to validate the regression equations for flank wear and 5.82 % error was obtained. The optimal cutting parameters for the flank wear using S/N ratio were 160 m/min of cutting speed (level 1), 0.18 mm/rev of feed (level 1), 1.75 mm of depth of cut (level 2) and 2.97 mm2/s palm kernel oil based cutting fluid (level 3). ANOVA shows cutting speed of 85.36 %; and feed rate 4.81 %) as significant factors.

  3. Performance Testing of Thermal Cutting Systems for Sweet Pepper Harvesting Robot in Greenhouse Horticulture

    NASA Astrophysics Data System (ADS)

    Bachche, Shivaji; Oka, Koichi

    2013-03-01

    This paper proposes design of end-effector and prototype of thermal cutting system for harvesting sweet peppers. The design consists of two parallel gripper bars mounted on a frame connected by specially designed notch plate and operated by servo motor. Based on voltage and current, two different types of thermal cutting system prototypes; electric arc and temperature arc respectively were developed and tested for performance. In electric arc, a special electric device was developed to obtain high voltage to perform cutting operation. At higher voltage, electrodes generate thermal arc which helps to cut stem of sweet pepper. In temperature arc, nichrome wire was mounted between two electrodes and current was provided directly to electrodes which results in generation of high temperature arc between two electrodes that help to perform cutting operation. In both prototypes, diameters of basic elements were varied and the effect of this variation on cutting operation was investigated. The temperature arc thermal system was found significantly suitable for cutting operation than electric arc thermal system. In temperature arc thermal cutting system, 0.5 mm nichrome wire shows significant results by accomplishing harvesting operation in 1.5 seconds. Also, thermal cutting system found suitable to increase shelf life of fruits by avoiding virus and fungal transformation during cutting process and sealing the fruit stem. The harvested sweet peppers by thermal cutting system can be preserved at normal room temperature for more than 15 days without any contamination.

  4. The effect of dentine surface preparation and reduced application time of adhesive on bonding strength.

    PubMed

    Saikaew, Pipop; Chowdhury, A F M Almas; Fukuyama, Mai; Kakuda, Shinichi; Carvalho, Ricardo M; Sano, Hidehiko

    2016-04-01

    This study evaluated the effects of surface preparation and the application time of adhesives on the resin-dentine bond strengths with universal adhesives. Sixty molars were cut to exposed mid-coronal dentine and divided into 12 groups (n=5) based on three factors; (1) adhesive: G-Premio Bond (GP, GC Corp., Tokyo, Japan), Clearfil Universal Bond (CU, Kuraray Noritake Dental Inc., Okayama, Japan) and Scotchbond Universal Adhesive (SB, 3M ESPE, St. Paul, MN, USA); (2) smear layer preparation: SiC paper ground dentine or bur-cut dentine; (3) application time: shortened time or as manufacturer's instruction. Fifteen resin-dentine sticks per group were processed for microtensile bond strength test (μTBS) according to non-trimming technique (1mm(2)) after storage in distilled water (37 °C) for 24h. Data were analyzed by three-way ANOVA and Dunnett T3 tests (α=0.05). Fractured surfaces were observed under scanning electron microscope (SEM). Another 12 teeth were prepared and cut into slices for SEM examination of bonded interfaces. μTBS were higher when bonded to SiC-ground dentine according to manufacturer's instruction. Bonding to bur-cut dentine resulted in significantly lower μTBS (p<0.000). Shortening the application time resulted in significantly lower bond strength for CU on SiC and GP on bur-cut dentine. SEM of fractured surfaces revealed areas with a large amount of porosities at the adhesive resin interface. This was more pronounced when adhesives were bonded with a reduced application time and on bur cut dentine. The performance of universal adhesives can be compromised on bur cut dentine and when applied with a reduced application time. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Robotic-Arm Assisted Total Knee Arthroplasty Demonstrated Greater Accuracy and Precision to Plan Compared with Manual Techniques.

    PubMed

    Hampp, Emily L; Chughtai, Morad; Scholl, Laura Y; Sodhi, Nipun; Bhowmik-Stoker, Manoshi; Jacofsky, David J; Mont, Michael A

    2018-05-01

    This study determined if robotic-arm assisted total knee arthroplasty (RATKA) allows for more accurate and precise bone cuts and component position to plan compared with manual total knee arthroplasty (MTKA). Specifically, we assessed the following: (1) final bone cuts, (2) final component position, and (3) a potential learning curve for RATKA. On six cadaver specimens (12 knees), a MTKA and RATKA were performed on the left and right knees, respectively. Bone-cut and final-component positioning errors relative to preoperative plans were compared. Median errors and standard deviations (SDs) in the sagittal, coronal, and axial planes were compared. Median values of the absolute deviation from plan defined the accuracy to plan. SDs described the precision to plan. RATKA bone cuts were as or more accurate to plan based on nominal median values in 11 out of 12 measurements. RATKA bone cuts were more precise to plan in 8 out of 12 measurements ( p  ≤ 0.05). RATKA final component positions were as or more accurate to plan based on median values in five out of five measurements. RATKA final component positions were more precise to plan in four out of five measurements ( p  ≤ 0.05). Stacked error results from all cuts and implant positions for each specimen in procedural order showed that RATKA error was less than MTKA error. Although this study analyzed a small number of cadaver specimens, there were clear differences that separated these two groups. When compared with MTKA, RATKA demonstrated more accurate and precise bone cuts and implant positioning to plan. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  6. Study of mandible reconstruction using a fibula flap with application of additive manufacturing technology.

    PubMed

    Tsai, Ming-June; Wu, Ching-Tsai

    2014-05-06

    This study aimed to establish surgical guiding techniques for completing mandible lesion resection and reconstruction of the mandible defect area with fibula sections in one surgery by applying additive manufacturing technology, which can reduce the surgical duration and enhance the surgical accuracy and success rate. A computer assisted mandible reconstruction planning (CAMRP) program was used to calculate the optimal cutting length and number of fibula pieces and design the fixtures for mandible cutting, registration, and arrangement of the fibula segments. The mandible cutting and registering fixtures were then generated using an additive manufacturing system. The CAMRP calculated the optimal fibula cutting length and number of segments based on the location and length of the defective portion of the mandible. The mandible cutting jig was generated according to the boundary surface of the lesion resection on the mandible STL model. The fibular cutting fixture was based on the length of each segment, and the registered fixture was used to quickly arrange the fibula pieces into the shape of the defect area. In this study, the mandibular lesion was reconstructed using registered fibular sections in one step, and the method is very easy to perform. The application of additive manufacturing technology provided customized models and the cutting fixtures and registered fixtures, which can improve the efficiency of clinical application. This study showed that the cutting fixture helped to rapidly complete lesion resection and fibula cutting, and the registered fixture enabled arrangement of the fibula pieces and allowed completion of the mandible reconstruction in a timely manner. Our method can overcome the disadvantages of traditional surgery, which requires a long and different course of treatment and is liable to cause error. With the help of optimal cutting planning by the CAMRP and the 3D printed mandible resection jig and fibula cutting fixture, this all-in-one process of mandible reconstruction furnishes many benefits in this field by enhancing the accuracy of surgery, shortening the operation duration, reducing the surgical risk, and resulting in a better mandible appearance of the patients after surgery.

  7. Study of mandible reconstruction using a fibula flap with application of additive manufacturing technology

    PubMed Central

    2014-01-01

    Background This study aimed to establish surgical guiding techniques for completing mandible lesion resection and reconstruction of the mandible defect area with fibula sections in one surgery by applying additive manufacturing technology, which can reduce the surgical duration and enhance the surgical accuracy and success rate. Methods A computer assisted mandible reconstruction planning (CAMRP) program was used to calculate the optimal cutting length and number of fibula pieces and design the fixtures for mandible cutting, registration, and arrangement of the fibula segments. The mandible cutting and registering fixtures were then generated using an additive manufacturing system. The CAMRP calculated the optimal fibula cutting length and number of segments based on the location and length of the defective portion of the mandible. The mandible cutting jig was generated according to the boundary surface of the lesion resection on the mandible STL model. The fibular cutting fixture was based on the length of each segment, and the registered fixture was used to quickly arrange the fibula pieces into the shape of the defect area. In this study, the mandibular lesion was reconstructed using registered fibular sections in one step, and the method is very easy to perform. Results and conclusion The application of additive manufacturing technology provided customized models and the cutting fixtures and registered fixtures, which can improve the efficiency of clinical application. This study showed that the cutting fixture helped to rapidly complete lesion resection and fibula cutting, and the registered fixture enabled arrangement of the fibula pieces and allowed completion of the mandible reconstruction in a timely manner. Our method can overcome the disadvantages of traditional surgery, which requires a long and different course of treatment and is liable to cause error. With the help of optimal cutting planning by the CAMRP and the 3D printed mandible resection jig and fibula cutting fixture, this all-in-one process of mandible reconstruction furnishes many benefits in this field by enhancing the accuracy of surgery, shortening the operation duration, reducing the surgical risk, and resulting in a better mandible appearance of the patients after surgery. PMID:24885749

  8. Tensor integrand reduction via Laurent expansion

    DOE PAGES

    Hirschi, Valentin; Peraro, Tiziano

    2016-06-09

    We introduce a new method for the application of one-loop integrand reduction via the Laurent expansion algorithm, as implemented in the public C++ library Ninja. We show how the coefficients of the Laurent expansion can be computed by suitable contractions of the loop numerator tensor with cut-dependent projectors, making it possible to interface Ninja to any one-loop matrix element generator that can provide the components of this tensor. We implemented this technique in the Ninja library and interfaced it to MadLoop, which is part of the public MadGraph5_aMC@NLO framework. We performed a detailed performance study, comparing against other public reductionmore » tools, namely CutTools, Samurai, IREGI, PJFry++ and Golem95. We find that Ninja out-performs traditional integrand reduction in both speed and numerical stability, the latter being on par with that of the tensor integral reduction tool Golem95 which is however more limited and slower than Ninja. Lastly, we considered many benchmark multi-scale processes of increasing complexity, involving QCD and electro-weak corrections as well as effective non-renormalizable couplings, showing that Ninja’s performance scales well with both the rank and multiplicity of the considered process.« less

  9. Effect of micro-scale texturing on the cutting tool performance

    NASA Astrophysics Data System (ADS)

    Vasumathy, D.; Meena, Anil

    2018-05-01

    The present study is mainly focused on the cutting performance of the micro-scale textured carbide tools while turning AISI 304 austenitic stainless steel under dry cutting environment. The texture on the rake face of the carbide tools was fabricated by laser machining. The cutting performance of the textured tools was further compared with conventional tools in terms of cutting forces, tool wear, machined surface quality and chip curl radius. SEM and EDS analyses have been also performed to better understand the tool surface characteristics. Results show that the grooves help in breaking the tool-chip contact leading to a lesser tool-chip contact area which results in reduced iron (Fe) adhesion to the tool.

  10. 3D force/torque characterization of emergency cricothyroidotomy procedure using an instrumented scalpel.

    PubMed

    Ryason, Adam; Sankaranarayanan, Ganesh; Butler, Kathryn L; DeMoya, Marc; De, Suvranu

    2016-08-01

    Emergency Cricothyroidotomy (CCT) is a surgical procedure performed to secure a patient's airway. This high-stakes, but seldom-performed procedure is an ideal candidate for a virtual reality simulator to enhance physician training. For the first time, this study characterizes the force/torque characteristics of the cricothyroidotomy procedure, to guide development of a virtual reality CCT simulator for use in medical training. We analyze the upper force and torque thresholds experienced at the human-scalpel interface. We then group individual surgical cuts based on style of cut and cut medium and perform a regression analysis to create two models that allow us to predict the style of cut performed and the cut medium.

  11. Feasibility of Tactical Air Delivery Resupply Using Gliders

    DTIC Science & Technology

    2016-12-01

    using modern design and manufacturing techniques including AutoCAD, 3D printing , laser cutting and CorelDraw, and conducting field testing and...Sparrow,” using modern design and manufacturing techniques including AutoCAD, 3D printing , laser cutting and CorelDraw, and conducting field testing and...the desired point(s) of impact due to the atmospheric three-dimensional ( 3D ) wind and density field encountered by the descending load under canopy

  12. The Effects of Operational Parameters on a Mono-wire Cutting System: Efficiency in Marble Processing

    NASA Astrophysics Data System (ADS)

    Yilmazkaya, Emre; Ozcelik, Yilmaz

    2016-02-01

    Mono-wire block cutting machines that cut with a diamond wire can be used for squaring natural stone blocks and the slab-cutting process. The efficient use of these machines reduces operating costs by ensuring less diamond wire wear and longer wire life at high speeds. The high investment costs of these machines will lead to their efficient use and reduce production costs by increasing plant efficiency. Therefore, there is a need to investigate the cutting performance parameters of mono-wire cutting machines in terms of rock properties and operating parameters. This study aims to investigate the effects of the wire rotational speed (peripheral speed) and wire descending speed (cutting speed), which are the operating parameters of a mono-wire cutting machine, on unit wear and unit energy, which are the performance parameters in mono-wire cutting. By using the obtained results, cuttability charts for each natural stone were created on the basis of unit wear and unit energy values, cutting optimizations were performed, and the relationships between some physical and mechanical properties of rocks and the optimum cutting parameters obtained as a result of the optimization were investigated.

  13. Lung tumor segmentation in PET images using graph cuts.

    PubMed

    Ballangan, Cherry; Wang, Xiuying; Fulham, Michael; Eberl, Stefan; Feng, David Dagan

    2013-03-01

    The aim of segmentation of tumor regions in positron emission tomography (PET) is to provide more accurate measurements of tumor size and extension into adjacent structures, than is possible with visual assessment alone and hence improve patient management decisions. We propose a segmentation energy function for the graph cuts technique to improve lung tumor segmentation with PET. Our segmentation energy is based on an analysis of the tumor voxels in PET images combined with a standardized uptake value (SUV) cost function and a monotonic downhill SUV feature. The monotonic downhill feature avoids segmentation leakage into surrounding tissues with similar or higher PET tracer uptake than the tumor and the SUV cost function improves the boundary definition and also addresses situations where the lung tumor is heterogeneous. We evaluated the method in 42 clinical PET volumes from patients with non-small cell lung cancer (NSCLC). Our method improves segmentation and performs better than region growing approaches, the watershed technique, fuzzy-c-means, region-based active contour and tumor customized downhill. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  14. Investigation of radiation hardened SOI wafer fabricated by ion-cut technique

    NASA Astrophysics Data System (ADS)

    Chang, Yongwei; Wei, Xing; Zhu, Lei; Su, Xin; Gao, Nan; Dong, Yemin

    2018-07-01

    Total ionizing dose (TID) effect on Silicon-on-Insulator (SOI) wafers due to inherent buried oxide (BOX) is a significant concern as it leads to the degradation of electrical properties of SOI-based devices and circuits, even failures of the systems associated with them. This paper reports the radiation hardening implementation of SOI wafer fabricated by ion-cut technique integrated with low-energy Si+ implantation. The electrical properties and radiation response of pseudo-MOS transistors are analyzed. The results demonstrate that the hardening process can significantly improve the TID tolerance of SOI wafers by generating Si nanocrystals (Si-NCs) within the BOX. The presence of Si-NCs created through Si+ implantation is evidenced by high-resolution transmission electron microscopy (HR-TEM). Under the pass gate (PG) irradiation bias, the anti-radiation properties of H-gate SOI nMOSFETs suggest that the radiation hardened SOI wafers with optimized Si implantation dose can perform effectively in a radiation environment. The radiation hardening process provides an excellent way to reinforce the TID tolerance of SOI wafers.

  15. Core Cutting Test with Vertical Rock Cutting Rig (VRCR)

    NASA Astrophysics Data System (ADS)

    Yasar, Serdar; Osman Yilmaz, Ali

    2017-12-01

    Roadheaders are frequently used machines in mining and tunnelling, and performance prediction of roadheaders is important for project economics and stability. Several methods were proposed so far for this purpose and, rock cutting tests are the best choice. Rock cutting tests are generally divided into two groups which are namely, full scale rock cutting tests and small scale rock cutting tests. These two tests have some superiorities and deficiencies over themselves. However, in many cases, where rock sampling becomes problematic, small scale rock cutting test (core cutting test) is preferred for performance prediction, since small block samples and core samples can be conducted to rock cutting testing. Common problem for rock cutting tests are that they can be found in very limited research centres. In this study, a new mobile rock cutting testing equipment, vertical rock cutting rig (VRCR) was introduced. Standard testing procedure was conducted on seven rock samples which were the part of a former study on cutting rocks with another small scale rock cutting test. Results showed that core cutting test can be realized successfully with VRCR with the validation of paired samples t-test.

  16. Shielded Metal Arc Welding and Carbon Arc Cutting--Air. Teacher Edition [and] Student Edition [and] Student Workbook. Third Edition.

    ERIC Educational Resources Information Center

    Harper, Eddie; Knapp, John

    This document contains the teacher and student texts and student workbook for a secondary-level course in shielded metal arc welding (SMAW) and carbon arc cutting that consists of units on the following topics: SMAW safety; SMAW equipment, applications, and techniques; hardfacing; and carbon arc cutting--air. The teacher edition includes the…

  17. Quantification of cancellous bone-compaction due to DHS Blade insertion and influence upon cut-out resistance.

    PubMed

    Windolf, Markus; Muths, Raphael; Braunstein, Volker; Gueorguiev, Boyko; Hänni, Markus; Schwieger, Karsten

    2009-01-01

    Compaction of cancellous bone is believed to prevent cut-out. This in vitro study quantified the compaction in the femoral head due to insertion of a dynamic hip screw-blade with and without predrilling and investigated the resulting implant anchorage under cyclic loading. Eight pairs of human cadaveric femoral heads were instrumented with a dynamic hip screw-blade made of Polyetheretherketon. Pairwise instrumentation was performed either with or without predrilling the specimens. CT scanning was performed before and after implantation, to measure bone-compaction. Subsequently the implant was removed and a third scan was performed to analyze the relaxation of the bone structure. Commercial implants were reinserted and the specimens were cyclically loaded until onset of cut-out occurred. The bone-implant interface was monitored by means of fluoroscopic imaging throughout the experiment. Paired t-tests were performed to identify differences regarding compaction, relaxation and cycles to failure. Bone density in the surrounding of the implant increased about 30% for the non-predrilled and 20% for the predrilled group when inserting the implant. After implant removal the predrilled specimens fully relaxed; the non-predrilled group showed about 10% plastic deformation. No differences were found regarding cycles to failure (P=0.32). Significant bone-compaction due to blade insertion was verified. Even though compaction was lower when predrilling the specimens, mainly elastic deformation was present, which is believed to primarily enhance the implant anchorage. Cyclic loading tests confirmed this thesis. The importance of the implantation technique with regard to predrilling is therefore decreased.

  18. In vitro comparison of the effect of piezosurgery and conventional bone preparation technique on intraosseous heat generation.

    PubMed

    Cziriak, N B; Szalma, J; Vag, J; Bogdan, S

    2016-09-01

    The aim of this in vitro study was to compare the effect of sagittal saw handpiece with a piezoelectric device on the rise in intraosseous temperature and on the preparation time. 100 native pieces of pork ribs were cut either with S-8 S handpiece connected to Elcomed surgical motor (W&H) (n = 30) or with B6 insert connected to Piezomed (W&H) using continuous movement (n = 30) or with B6 using short breaks to perform intermittent cutting (n = 30). The rest were cut either by S-8 S (n = 5) or by B6 (n = 5) both applied by permanent pressure. The intraosseous temperature was measured by K-type thermocouple connected to digital thermometer placed in the bone 1 mm away of the cutting line. The heat generated and the time of the complete cutting were recorded. In S-8 S group the temperature never rose above 47⁰C. Using the B6 with permanent movement the critical temperature was reached in 16.2 ± 3.53% of the cases while taking breaks decreased the results to 2.6 ? 0.96% (p <0.001). In no cases the temperature elevation above 4700 lasted more than 60 sec. Applying the B6 by permanent pressure resulted in heat up to 90.3⁰C. Our results suggest that piezoelectric device could use safely according to the factory instructions, however further reduce of heat load could be achieved if the intermittent cutting motion combined with short-time cooling periods.

  19. Application of plant growth regulators, a simple technique for improving the establishment success of plant cuttings in coastal dune restoration

    NASA Astrophysics Data System (ADS)

    Balestri, Elena; Vallerini, Flavia; Castelli, Alberto; Lardicci, Claudio

    2012-03-01

    Exogenous application of plant growth regulators (PGRs) may be an effective technique for increasing the rooting ability and the growth of vegetative fragments (cuttings) of plants used in dune restoration programs. Various concentrations (0, 50 and 100 mg l-1) of two auxins, alpha-naphtaleneacetic acid (NAA) and indole-3-butyric acid (IBA), and two cytokinins, 6-furfurylaminopurine (Kinetin) and 6-benzylaminopurine (BAP), were applied separately to cuttings of two widely used species for restoration, Ammophila arenaria and Sporobuls virginicus. Root development and production of new buds in cuttings were examined under laboratory conditions one month after application. Cuttings were also examined one year after transplanting into a sandy substratum under natural conditions, to test for possible long term effects of PGRs on plant establishment success and growth. The response of the two study species to PGRs differed substantially. In A. arenaria the auxin NAA at 100 mg l-1 reduced the time for root initiation and increased the rooting capacity of cuttings, while the cytokinin Kinetin at 50 mg l-1 facilitated root growth. No auxin had effect on rooting or growth of S. virginicus cuttings, but treatment with 100 mg l-1 Kinetin resulted in higher rooting success than the control. One year after planting, the cuttings of A. arenaria treated with 100 mg l-1 NAA showed a higher establishment success (90% vs. 55%) and produced more culms and longer roots than the control; those treated with cytokinins did not differ in the establishment success from the control, but had longer roots, more culms and rhizomes. On the other hand, the cuttings of S. virginicus treated with 100 mg l-1 Kinetin showed a higher establishment success (75% vs. 35%) and had more culms than the control. Therefore, in restoration activities that involved A. arenaria, a pre-treatment of cuttings with NAA would be beneficial, as it allows the production of a higher number of well-developed plants with high survival potential and greater area cover. In contrast, a pre-treatment of cuttings of S. virginicus with Kinetin would achieve more acceptable plant survival rates. This easy and low cost-effective technique may be extended to other dune plant species and applied on a large scale to improve the chance of dune restoration success.

  20. Comparative study of pulsed laser cleaning applied to weathered marble surfaces

    NASA Astrophysics Data System (ADS)

    Ortiz, P.; Antúnez, V.; Ortiz, R.; Martín, J. M.; Gómez, M. A.; Hortal, A. R.; Martínez-Haya, B.

    2013-10-01

    The removal of unwanted matter from surface stones is a demanding task in the conservation of cultural heritage. This paper investigates the effectiveness of near-infrared (IR) and ultraviolet (UV) laser pulses for the cleaning of surface deposits, iron oxide stains and different types of graffiti (black, red and green sprays and markers, and black cutting-edge ink) on dolomitic white marble. The performance of the laser techniques is compared to common cleaning methods on the same samples, namely pressurized water and chemical treatments. The degree of cleaning achieved with each technique is assessed by means of colorimetric measurements and X-ray microfluorescence. Eventual morphological changes induced on the marble substrate are monitored with optical and electronic microscopy. It is found that UV pulsed laser ablation at 266 nm manages to clean all the stains except the cutting-edge ink, although some degree of surface erosion is produced. The IR laser pulses at 1064 nm can remove surface deposits and black spray acceptably, but a yellowing is observed on the stone surface after treatment. An economic evaluation shows that pulsed laser cleaning techniques are advantageous for the rapid cleaning of small or inaccessible surface areas, although their extensive application becomes expensive due to the long operating times required.

  1. Mist Propagation of Juvenile Oak Cuttings

    Treesearch

    R. E. Farmer

    1965-01-01

    Greenwood apical cuttings from 1- to 4-month-old cherrybark oak (Quercus falcata var. pagodaefolia Ell.) seedlings have been rooted in 4 weeks under mist, after treatment with indolebutyric acid. The technique is suitable for establishing small clones.

  2. Steep cut slope composting : field trials and evaluation.

    DOT National Transportation Integrated Search

    2011-04-01

    Three different depths of compost and five compost retention techniques were tested to determine : their efficacy and cost effectiveness for increasing the establishment of native grass seedings and decreasing : erosion on steep roadside cut slopes i...

  3. Method and system for assigning a confidence metric for automated determination of optic disc location

    DOEpatents

    Karnowski, Thomas P [Knoxville, TN; Tobin, Jr., Kenneth W.; Muthusamy Govindasamy, Vijaya Priya [Knoxville, TN; Chaum, Edward [Memphis, TN

    2012-07-10

    A method for assigning a confidence metric for automated determination of optic disc location that includes analyzing a retinal image and determining at least two sets of coordinates locating an optic disc in the retinal image. The sets of coordinates can be determined using first and second image analysis techniques that are different from one another. An accuracy parameter can be calculated and compared to a primary risk cut-off value. A high confidence level can be assigned to the retinal image if the accuracy parameter is less than the primary risk cut-off value and a low confidence level can be assigned to the retinal image if the accuracy parameter is greater than the primary risk cut-off value. The primary risk cut-off value being selected to represent an acceptable risk of misdiagnosis of a disease having retinal manifestations by the automated technique.

  4. Preceding bronchial cutting for exposure of the pulmonary artery buried in scar tissue after chemoradiotherapy.

    PubMed

    Nomori, Hiroaki; Cong, Yue; Sugimura, Hiroshi

    2017-01-01

    It is often difficult to expose the pulmonary artery buried in a scar tissue, especially in lung cancer patients that responded well to neoadjuvant chemoradiotherapy. Difficulty to access pulmonary artery branches may lead to potentially unnecessary pneumonectomy. To complete lobectomy in such cases, a technique with preceding bronchial cutting for exposure of the pulmonary artery is presented. After dissecting the pulmonary vein, the lobar bronchus is cut from the opposite side of the pulmonary artery with scissors. The back wall of the lobar bronchus is cut using a surgical knife from the luminal face, which can expose the pulmonary artery behind the bronchial stump and then complete lobectomy. Fourteen patients have been treated using the present technique, enabling complete resection by lobectomy (including sleeve lobectomy in 3 patients) without major bleeding. The present procedure can expose pulmonary artery buried in scar tissue, resulting in making the lobectomy safer.

  5. Use of small gap anastomosis for the repair of peripheral nerve injury by cutting and sleeve jointing the epineurium.

    PubMed

    Wang, Peiji; Zhao, Jiaju; Jiang, Bo; Zhang, Yong

    2015-05-01

    Although epineurium neurorrhaphy is the most reliable and conventional method for the repair of peripheral nerve injury and is accepted as the gold standard, it is still far from ideal. Many attempts have been made to develop nerve anastomosis techniques. The aim of this study was to investigate the use of small gap anastomosis performed by cutting and sleeve jointing the epineurium for nerve repair. A 12-week study was performed using small gap anastomosis via cutting and sleeve jointing the epineurium, compared with epineurium neurorrhaphy in situ, to repair a rat sciatic nerve rupture. Three experimental groups were included: sham control (n = 8), small gap anastomosis (n = 16), and epineurium neurorrhaphy (n = 16). About 12 weeks after surgery, recovery was assessed with walking track analysis, electrophysiology, hematoxylin and eosin staining, immunohistochemistry, and electron microscopy. The sciatic nerve functional index observed in the small gap anastomosis group was significantly higher than that in the epineurium neurorrhaphy group (p < 0.05). In vivo electrophysiological analysis confirmed that the small gap anastomosis group showed a significantly higher conduction velocity than the epineurium neurorrhaphy group (p < 0.05). Postoperative morphometric analysis revealed better results after small gap anastomosis compared with epineurium neurorrhaphy. Small gap anastomosis via cutting and sleeve jointing the epineurium could be an alternative to epineurium neurorrhaphy for the repair of peripheral nerve injury, particularly, considering that the epineurium originates from native tissue that provides a suitable microenvironment for the selective regeneration of axons. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  6. Predicting the Performance of Chain Saw Machines Based on Shore Scleroscope Hardness

    NASA Astrophysics Data System (ADS)

    Tumac, Deniz

    2014-03-01

    Shore hardness has been used to estimate several physical and mechanical properties of rocks over the last few decades. However, the number of researches correlating Shore hardness with rock cutting performance is quite limited. Also, rather limited researches have been carried out on predicting the performance of chain saw machines. This study differs from the previous investigations in the way that Shore hardness values (SH1, SH2, and deformation coefficient) are used to determine the field performance of chain saw machines. The measured Shore hardness values are correlated with the physical and mechanical properties of natural stone samples, cutting parameters (normal force, cutting force, and specific energy) obtained from linear cutting tests in unrelieved cutting mode, and areal net cutting rate of chain saw machines. Two empirical models developed previously are improved for the prediction of the areal net cutting rate of chain saw machines. The first model is based on a revised chain saw penetration index, which uses SH1, machine weight, and useful arm cutting depth as predictors. The second model is based on the power consumed for only cutting the stone, arm thickness, and specific energy as a function of the deformation coefficient. While cutting force has a strong relationship with Shore hardness values, the normal force has a weak or moderate correlation. Uniaxial compressive strength, Cerchar abrasivity index, and density can also be predicted by Shore hardness values.

  7. Cutting thread at flexible endoscopy.

    PubMed

    Gong, F; Swain, P; Kadirkamanathan, S; Hepworth, C; Laufer, J; Shelton, J; Mills, T

    1996-12-01

    New thread-cutting techniques were developed for use at flexible endoscopy. A guillotine was designed to follow and cut thread at the endoscope tip. A new method was developed for guiding suture cutters. Efficacy of Nd: YAG laser cutting of threads was studied. Experimental and clinical experience with thread-cutting methods is presented. A 2.4 mm diameter flexible thread-cutting guillotine was constructed featuring two lateral holes with sharp edges through which sutures to be cut are passed. Standard suture cutters were guided by backloading thread through the cutters extracorporeally. A snare cutter was constructed to retrieve objects sewn to tissue. Efficacy and speed of Nd: YAG laser in cutting twelve different threads were studied. The guillotine cut thread faster (p < 0.05) than standard suture cutters. Backloading thread shortened time taken to cut thread (p < 0.001) compared with free-hand cutting. Nd: YAG laser was ineffective in cutting uncolored threads and slower than mechanical cutters. Results of thread cutting in clinical studies using sewing machine (n = 77 cutting episodes in 21 patients), in-vivo experiments (n = 156), and postsurgical cases (n = 15 over 15 years) are presented. New thread-cutting methods are described and their efficacy demonstrated in experimental and clinical studies.

  8. Investigating bone chip formation in craniotomy.

    PubMed

    Huiyu, He; Chengyong, Wang; Yue, Zhang; Yanbin, Zheng; Linlin, Xu; Guoneng, Xie; Danna, Zhao; Bin, Chen; Haoan, Chen

    2017-10-01

    In a craniotomy, the milling cutter is one of the most important cutting tools. The operating performance, tool durability and cutting damage to patients are influenced by the tool's sharpness, intensity and structure, whereas the cutting characteristics rely on interactions between the tool and the skull. In this study, an orthogonal cutting experiment during a craniotomy of fresh pig skulls was performed to investigate chip formation on the side cutting and face cutting of the skull using a high-speed camera. The cutting forces with different combinations of cutting parameters, such as the rake angle, clearance angle, depth of cut and cutting speed, were measured. The skull bone microstructure and cutting damage were observed by scanning electron microscope. Cutting models for different cutting approaches and various depths of cut were constructed and analyzed. The study demonstrated that the effects of shearing, tension and extrusion occur during chip formation. Various chip types, such as unit chips, splintering chips and continuous chips, were generated. Continuous pieces of chips, which are advisable for easy removal from the field of operation, were formed at greater depths of cut and tool rake angles greater than 10°. Cutting damage could be relieved with a faster recovery with clearance angles greater than 20°.

  9. Development of Minimally Invasive Medical Tools Using Laser Processing on Cylindrical Substrates

    NASA Astrophysics Data System (ADS)

    Haga, Yoichi; Muyari, Yuta; Goto, Shoji; Matsunaga, Tadao; Esashi, Masayoshi

    This paper reports micro-fabrication techniques using laser processing on cylindrical substrates for the realization of high-performance multifunctional minimally invasive medical tools with small sizes. A spring-shaped shape memory alloy (SMA) micro-coil with a square cross section has been fabricated by spiral cutting of a Ti-Ni SMA tube with a femtosecond laser. Small diameter active bending catheter which is actuated by hydraulic suction mechanism for intravascular minimally invasive diagnostics and therapy has also been developed. The catheter is made of a Ti-Ni super elastic alloy (SEA) tube which is processed by laser micromachining and a silicone rubber tube which covers the outside of the SEA tube. The active catheter is effective for insertion in branch of blood vessel which diverse in acute angle which is difficult to proceed. Multilayer metallization and patterning have been performed on glass tubes with 2 and 3 mm external diameters using maskless lithography techniques using a laser exposure system. Using laser soldering technique, a integrated circuit parts have been mounted on a multilayer circuit patterned on a glass tube. These fabrication techniques will effective for realization of high-performance multifunctional catheters, endoscopic tools, and implanted small capsules.

  10. In vitro comparison of the cutting efficiency and temperature production of 10 different rotary cutting instruments. Part I: Turbine.

    PubMed

    Ercoli, Carlo; Rotella, Mario; Funkenbusch, Paul D; Russell, Scott; Feng, Changyong

    2009-04-01

    Standards to test the cutting efficiency of dental rotary cutting instruments are either nonexistent or inappropriate, and knowledge of the factors that affect their cutting performance is limited. Therefore, rotary cutting instruments for crown preparation are generally marketed with weak or unsupported claims of superior performance. The purpose of this study was to examine the cutting behavior of a wide selection of rotary cutting instruments under carefully controlled and reproducible conditions with an air-turbine handpiece. Ten groups of rotary cutting instruments (n=30) designed for tooth preparation were selected: 9 diamond rotary cutting instruments (7 multi-use, 2 disposable) and 1 carbide bur. One bur per group was imaged with a scanning electron microscope (SEM) at different magnifications. Macor blocks (n=75) were used as a substrate, and 4 cuts were made on each specimen, using a new rotary cutting instrument each time, for a total of 300 cuts. The cuts were performed with an air-turbine handpiece (Midwest Quiet Air). A computer-controlled, custom-made testing apparatus was used to monitor all sensors and control the cutting action. The data were analyzed to compare the correlation of rotary cutting instrument type, grit, amount of pressure, cutting rate, revolutions per minute (rpm), temperature, and type of handpiece, using 1-way ANOVA and Tukey's Studentized Range test (alpha=.05). Compared to the baseline temperature, all rotary cutting instruments showed a reduction of temperature in the simulated pulp chamber. The Great White Ultra (carbide bur) showed a significantly higher rate of advancement (0.15 mm/s) and lower applied load (106.46 g) and rpm (304,375.97). Tooth preparation with an adequate water flow does not cause harmful temperature changes in the pulp chamber, regardless of rotary cutting instrument type. The tested carbide bur showed greater cutting efficiency than all diamond rotary cutting instruments.

  11. A new method to measure circular runout of end-milling spindle based on cutting mark

    NASA Astrophysics Data System (ADS)

    Zhou, Jianlai; Liu, Shuchun

    2008-12-01

    A practical method is introduced to measure the circular runout of a end-milling spindle system at high speed rotations without the need of a reference sphere. A workpiece is held on a linear slide which moves along the axial direction of the spindle. The spindle is then programmed to run at a specific speed. A very sharp edge cutter must be used and the depth of cut will be very shallow in order to keep the cutting force very small. The workpiece is then fed into the end mill in order to make a cutting mark of teens μm in depth. The cutting marks are circular, and their diameters are related to the circular runout of the spindle system. The cutting mark that is generated at a specific speed is expected to contain information about the spindle circular runout at this speed. In practice the cutting marks are not perfectly circular. Therefore, a best-fit circle of a cutting mark is needed to determine its diameter. A high-resolution edge detector machine is used for this purpose. Quantitative precision analysis was carried out to confirm the accuracy and repeatability of this new measurement technique. It is demonstrated that this technique for the measurement of spindle circular runout is an effective tool in verifying the actual running accuracy of spindles at their actual operating speeds and can be accomplished without the need for a reference sphere.

  12. Acute Effects of Static Stretching of Hamstring on Performance and Anterior Cruciate Ligament Injury Risk During Stop-Jump and Cutting Tasks in Female Athletes.

    PubMed

    Ruan, Mianfang; Zhang, Qiang; Wu, Xie

    2017-05-01

    Ruan, M, Zhang, Q, and Wu, X. Acute effects of static stretching of hamstring on performance and anterior cruciate ligament injury risk during stop-jump and cutting tasks in female athletes. J Strength Cond Res 31(5): 1241-1250, 2017-There is limited research investigating antagonist stretch. The purpose of this study was to evaluate the influence of static stretching of hamstrings (SSH) on performance and anterior cruciate ligament (ACL) injury risk during stop-jump and 180° cutting tasks. Twelve female college athletes (age 20.8 ± 0.7 years; height 1.61 ± 0.05 m; mass 54.25 ± 4.22 kg) participated in this study. Subjects performed stop-jump and 180° cutting tasks under 2 conditions: after warm-up with 4 × 30 seconds SSH or after warm-up without SSH. Three-dimensional kinematic and kinetic data as well as electromyography of biceps femoris, rectus femoris, vastus medialis, and gastrocnemius medialis were collected during testing. Static stretching of hamstrings significantly enhanced jump height by 5.1% (p = 0.009) but did not change the takeoff speed of cutting. No significant changes in peak knee adduction moment or peak anterior tibia shear force were observed with SSH regardless of the task. The peak lateral tibia shear force during cutting was significantly (p = 0.036) reduced with SSH. The co-contraction of hamstring and quadriceps during the preactivation (stop-jump: p = 0.04; cutting: p = 0.05) and downward phases (stop-jump: p = 0.04; cutting: p = 0.05) was significantly reduced after SSH regardless of the task. The results suggest that SSH enhanced the performance of stop-jump because of decreased co-contraction of hamstring and quadriceps but did not change the performance of cutting. In addition, SSH did not increase ACL injury risk during stop-jump and cutting tasks and even reduced medial-lateral knee loading during cutting.

  13. Acute Effects of Static Stretching of Hamstring on Performance and Anterior Cruciate Ligament Injury Risk During Stop-Jump and Cutting Tasks in Female Athletes

    PubMed Central

    Ruan, Mianfang; Zhang, Qiang

    2017-01-01

    Abstract Ruan, M, Zhang, Q, and Wu, X. Acute effects of static stretching of hamstring on performance and anterior cruciate ligament injury risk during stop-jump and cutting tasks in female athletes. J Strength Cond Res 31(5): 1241–1250, 2017—There is limited research investigating antagonist stretch. The purpose of this study was to evaluate the influence of static stretching of hamstrings (SSH) on performance and anterior cruciate ligament (ACL) injury risk during stop-jump and 180° cutting tasks. Twelve female college athletes (age 20.8 ± 0.7 years; height 1.61 ± 0.05 m; mass 54.25 ± 4.22 kg) participated in this study. Subjects performed stop-jump and 180° cutting tasks under 2 conditions: after warm-up with 4 × 30 seconds SSH or after warm-up without SSH. Three-dimensional kinematic and kinetic data as well as electromyography of biceps femoris, rectus femoris, vastus medialis, and gastrocnemius medialis were collected during testing. Static stretching of hamstrings significantly enhanced jump height by 5.1% (p = 0.009) but did not change the takeoff speed of cutting. No significant changes in peak knee adduction moment or peak anterior tibia shear force were observed with SSH regardless of the task. The peak lateral tibia shear force during cutting was significantly (p = 0.036) reduced with SSH. The co-contraction of hamstring and quadriceps during the preactivation (stop-jump: p = 0.04; cutting: p = 0.05) and downward phases (stop-jump: p = 0.04; cutting: p = 0.05) was significantly reduced after SSH regardless of the task. The results suggest that SSH enhanced the performance of stop-jump because of decreased co-contraction of hamstring and quadriceps but did not change the performance of cutting. In addition, SSH did not increase ACL injury risk during stop-jump and cutting tasks and even reduced medial-lateral knee loading during cutting. PMID:28118311

  14. Validation of an endothelial roll preparation for Descemet Membrane Endothelial Keratoplasty by a cornea bank using "no touch" dissection technique.

    PubMed

    Marty, Anne-Sophie; Burillon, Carole; Desanlis, Adeline; Damour, Odile; Kocaba, Viridiana; Auxenfans, Céline

    2016-06-01

    Descemet Membrane Endothelial Keratoplasty (DMEK) selectively replaces the damaged posterior part of the cornea. However, the DMEK technique relies on a manually-performed dissection that is time-consuming, requires training and presents a potential risk of endothelial graft damages leading to surgery postponement when performed by surgeons in the operative room. To validate precut corneal tissue preparation for DMEK provided by a cornea bank in order to supply a quality and security precut endothelial tissue. The protocol was a technology transfer from the Netherlands Institute for Innovative Ocular Surgery (NIIOS) to Lyon Cornea Bank, after formation in NIIOS to the DMEK "no touch" dissection technique. The technique has been validated in selected conditions (materials, microscope) and after a learning curve, cornea bank technicians prepared endothelial tissue for DMEK. Endothelial cells densities (ECD) were evaluated before and after preparation, after storage and transport to the surgery room. Microbiological and histological controls have been done. Twenty corneas were manually dissected; 18 without tears. Nineteen endothelial grafts formed a double roll. The ECD loss after cutting was 3.3 % (n = 19). After transportation 7 days later, we found an ECD loss of 25 % (n = 12). Three days after cutting and transportation, we found 2.1 % of ECD loss (n = 7). Histology found an endothelial cells monolayer lying on Descemet membrane. The mean thickness was 12 ± 2.2 µm (n = 4). No microbial contamination was found (n = 19). Endothelial roll stability has been validated at 3 days in our cornea bank. Cornea bank technicians trained can deliver to surgeons an ECD controlled, safety and ready to use endothelial tissue, for DMEK by "no touch" technique, allowing time saving, quality and security for surgeons.

  15. Applying a crop-tree release in small-sawtimber white oak stands

    Treesearch

    Jeffrey W Stringer; Gary W. Miller; Robert F. Wittwer; Robert F. Wittwer

    1988-01-01

    Small-sawtimber white oak crop trees in Kentucky were released by a crown-touching technique. In two cutting treatments, 20 and 34 crop trees were released per acre at a total cost of $35 and $42, respectively. Both treatments yielded commercial volumes of cut material. Total mean merchantable volume (> 5.0 inches d.b.h.) in cut trees was 693 cubic feet/acre, with...

  16. IN VITRO FLOW ANALYSIS OF NOVEL DOUBLE-CUTTING, OPEN-PORT, ULTRAHIGH-SPEED VITRECTOMY SYSTEMS.

    PubMed

    Zehetner, Claus; Moelgg, Marion; Bechrakis, Emmanouil; Linhart, Caroline; Bechrakis, Nikolaos E

    2017-10-09

    To analyze the performance and flow characteristics of novel double-cutting, open-port, 23-, 25-, and 27-gauge ultrahigh-speed vitrectomy systems. In vitro fluidic measurements were performed to assess the volumetric aspiration profiles of several vitrectomy systems in basic salt solution and egg white. Double-cutting open-port vitrectomy probes delivered stable aspiration flow rates that were less prone to flow variation affected by the cutting speed. Increase in cutting frequency to the maximum level resulted in flow reduction of less than 10% (0.0%-9.5%). Commercially available 23-, 25-, and 27-G double-cutting probes exhibited higher egg-white and basic salt solution flow rates at all evaluated cut rates, with aspirational efficiencies being 1.1 to 2.9 times the flow rates of standard single-blade vitrectomy probes of the same caliber at the maximum preset vacuum. The highest relative differences were observed at faster cut rates. The newly introduced double-cutting open-port vitrectomy probes delivered stable aspiration flow rates that were less prone to flow variation affected by the cutting speed. The fluidic principle of constant flow even at the highest cut rates and low vacuum levels might impact surgical strategies, especially when performing manipulations close to the retina.

  17. Energy Minimization of Discrete Protein Titration State Models Using Graph Theory.

    PubMed

    Purvine, Emilie; Monson, Kyle; Jurrus, Elizabeth; Star, Keith; Baker, Nathan A

    2016-08-25

    There are several applications in computational biophysics that require the optimization of discrete interacting states, for example, amino acid titration states, ligand oxidation states, or discrete rotamer angles. Such optimization can be very time-consuming as it scales exponentially in the number of sites to be optimized. In this paper, we describe a new polynomial time algorithm for optimization of discrete states in macromolecular systems. This algorithm was adapted from image processing and uses techniques from discrete mathematics and graph theory to restate the optimization problem in terms of "maximum flow-minimum cut" graph analysis. The interaction energy graph, a graph in which vertices (amino acids) and edges (interactions) are weighted with their respective energies, is transformed into a flow network in which the value of the minimum cut in the network equals the minimum free energy of the protein and the cut itself encodes the state that achieves the minimum free energy. Because of its deterministic nature and polynomial time performance, this algorithm has the potential to allow for the ionization state of larger proteins to be discovered.

  18. Energy Minimization of Discrete Protein Titration State Models Using Graph Theory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Purvine, Emilie AH; Monson, Kyle E.; Jurrus, Elizabeth R.

    There are several applications in computational biophysics which require the optimization of discrete interacting states; e.g., amino acid titration states, ligand oxidation states, or discrete rotamer angles. Such optimization can be very time-consuming as it scales exponentially in the number of sites to be optimized. In this paper, we describe a new polynomial-time algorithm for optimization of discrete states in macromolecular systems. This algorithm was adapted from image processing and uses techniques from discrete mathematics and graph theory to restate the optimization problem in terms of maximum flow-minimum cut graph analysis. The interaction energy graph, a graph in which verticesmore » (amino acids) and edges (interactions) are weighted with their respective energies, is transformed into a flow network in which the value of the minimum cut in the network equals the minimum free energy of the protein, and the cut itself encodes the state that achieves the minimum free energy. Because of its deterministic nature and polynomial-time performance, this algorithm has the potential to allow for the ionization state of larger proteins to be discovered.« less

  19. Real-time surgical simulation for deformable soft-tissue objects with a tumour using Boundary Element techniques

    NASA Astrophysics Data System (ADS)

    Wang, P.; Becker, A. A.; Jones, I. A.; Glover, A. T.; Benford, S. D.; Vloeberghs, M.

    2009-08-01

    A virtual-reality real-time simulation of surgical operations that incorporates the inclusion of a hard tumour is presented. The software is based on Boundary Element (BE) technique. A review of the BE formulation for real-time analysis of two-domain deformable objects, using the pre-solution technique, is presented. The two-domain BE software is incorporated into a surgical simulation system called VIRS to simulate the initiation of a cut on the surface of the soft tissue and extending the cut deeper until the tumour is reached.

  20. Laser vs bur for bone cutting in impacted mandibular third molar surgery: A randomized controlled trial

    PubMed Central

    Passi, Deepak; Pal, Uma Shankar; Mohammad, Shadab; Singh, Rakesh Kumar; Mehrotra, Divya; Singh, Geeta; Kumar, Manoj; Chellappa, Arul A.L.; Gupta, Chandan

    2013-01-01

    Background The aim of this study was to assess the feasibility of Er: YAG laser in bone cutting for removal of impacted lower third molar teeth and compare its outcomes with that of surgical bur. Materials & methods The study comprised 40 subjects requiring removal of impacted mandibular third molar, randomly categorized into two equal groups of 20 each, who had their impacted third molar removed either using Er: YAG laser or surgical bur as per their group, using standard methodology of extraction of impacted teeth. Clinical parameters like pain, bleeding, time taken for bone cutting, postoperative swelling, trismus, wound healing and complications were compared for both groups. Observation & result Clinical parameters like pain, bleeding and swelling were lower in laser group than bur group, although the difference was statistically not significant. However, postoperative swelling showed significant difference in the two groups. Laser group required almost double the time taken for bone cutting with bur. Trismus persisted for a longer period in laser group. Wound healing and complications were assessed clinically and there was no significant difference in both the groups. Conclusion Based on the results of our study, the possibility of bone cutting using lasers is pursued, the osteotomy is easily performed and the technique is better suited to minimally invasive surgical procedures. The use of Er: YAG laser may be considered as an alternative tool to surgical bur, specially in anxious patients. PMID:25737885

  1. Parallel Visualization Co-Processing of Overnight CFD Propulsion Applications

    NASA Technical Reports Server (NTRS)

    Edwards, David E.; Haimes, Robert

    1999-01-01

    An interactive visualization system pV3 is being developed for the investigation of advanced computational methodologies employing visualization and parallel processing for the extraction of information contained in large-scale transient engineering simulations. Visual techniques for extracting information from the data in terms of cutting planes, iso-surfaces, particle tracing and vector fields are included in this system. This paper discusses improvements to the pV3 system developed under NASA's Affordable High Performance Computing project.

  2. ILP-based co-optimization of cut mask layout, dummy fill, and timing for sub-14nm BEOL technology

    NASA Astrophysics Data System (ADS)

    Han, Kwangsoo; Kahng, Andrew B.; Lee, Hyein; Wang, Lutong

    2015-10-01

    Self-aligned multiple patterning (SAMP), due to its low overlay error, has emerged as the leading option for 1D gridded back-end-of-line (BEOL) in sub-14nm nodes. To form actual routing patterns from a uniform "sea of wires", a cut mask is needed for line-end cutting or realization of space between routing segments. Constraints on cut shapes and minimum cut spacing result in end-of-line (EOL) extensions and non-functional (i.e. dummy fill) patterns; the resulting capacitance and timing changes must be consistent with signoff performance analyses and their impacts should be minimized. In this work, we address the co-optimization of cut mask layout, dummy fill, and design timing for sub-14nm BEOL design. Our central contribution is an optimizer based on integer linear programming (ILP) to minimize the timing impact due to EOL extensions, considering (i) minimum cut spacing arising in sub-14nm nodes; (ii) cut assignment to different cut masks (color assignment); and (iii) the eligibility to merge two unit-size cuts into a bigger cut. We also propose a heuristic approach to remove dummy fills after the ILP-based optimization by extending the usage of cut masks. Our heuristic can improve critical path performance under minimum metal density and mask density constraints. In our experiments, we study the impact of number of cut masks, minimum cut spacing and metal density under various constraints. Our studies of optimized cut mask solutions in these varying contexts give new insight into the tradeoff of performance and cost that is afforded by cut mask patterning technology options.

  3. Experimental investigation and modelling of surface roughness and resultant cutting force in hard turning of AISI H13 Steel

    NASA Astrophysics Data System (ADS)

    Boy, M.; Yaşar, N.; Çiftçi, İ.

    2016-11-01

    In recent years, turning of hardened steels has replaced grinding for finishing operations. This process is compared to grinding operations; hard turning has higher material removal rates, the possibility of greater process flexibility, lower equipment costs, and shorter setup time. CBN or ceramic cutting tools are widely used hard part machining. For successful application of hard turning, selection of suitable cutting parameters for a given cutting tool is an important step. For this purpose, an experimental investigation was conducted to determine the effects of cutting tool edge geometry, feed rate and cutting speed on surface roughness and resultant cutting force in hard turning of AISI H13 steel with ceramic cutting tools. Machining experiments were conducted in a CNC lathe based on Taguchi experimental design (L16) in different levels of cutting parameters. In the experiments, a Kistler 9257 B, three cutting force components (Fc, Ff and Fr) piezoelectric dynamometer was used to measure cutting forces. Surface roughness measurements were performed by using a Mahrsurf PS1 device. For statistical analysis, analysis of variance has been performed and mathematical model have been developed for surface roughness and resultant cutting forces. The analysis of variance results showed that the cutting edge geometry, cutting speed and feed rate were the most significant factors on resultant cutting force while the cutting edge geometry and feed rate were the most significant factor for the surface roughness. The regression analysis was applied to predict the outcomes of the experiment. The predicted values and measured values were very close to each other. Afterwards a confirmation tests were performed to make a comparison between the predicted results and the measured results. According to the confirmation test results, measured values are within the 95% confidence interval.

  4. A fully-automated multiscale kernel graph cuts based particle localization scheme for temporal focusing two-photon microscopy

    NASA Astrophysics Data System (ADS)

    Huang, Xia; Li, Chunqiang; Xiao, Chuan; Sun, Wenqing; Qian, Wei

    2017-03-01

    The temporal focusing two-photon microscope (TFM) is developed to perform depth resolved wide field fluorescence imaging by capturing frames sequentially. However, due to strong nonignorable noises and diffraction rings surrounding particles, further researches are extremely formidable without a precise particle localization technique. In this paper, we developed a fully-automated scheme to locate particles positions with high noise tolerance. Our scheme includes the following procedures: noise reduction using a hybrid Kalman filter method, particle segmentation based on a multiscale kernel graph cuts global and local segmentation algorithm, and a kinematic estimation based particle tracking method. Both isolated and partial-overlapped particles can be accurately identified with removal of unrelated pixels. Based on our quantitative analysis, 96.22% isolated particles and 84.19% partial-overlapped particles were successfully detected.

  5. Tool path strategy and cutting process monitoring in intelligent machining

    NASA Astrophysics Data System (ADS)

    Chen, Ming; Wang, Chengdong; An, Qinglong; Ming, Weiwei

    2018-06-01

    Intelligent machining is a current focus in advanced manufacturing technology, and is characterized by high accuracy and efficiency. A central technology of intelligent machining—the cutting process online monitoring and optimization—is urgently needed for mass production. In this research, the cutting process online monitoring and optimization in jet engine impeller machining, cranio-maxillofacial surgery, and hydraulic servo valve deburring are introduced as examples of intelligent machining. Results show that intelligent tool path optimization and cutting process online monitoring are efficient techniques for improving the efficiency, quality, and reliability of machining.

  6. Complex Osteotomies of Tibial Plateau Malunions Using Computer-Assisted Planning and Patient-Specific Surgical Guides.

    PubMed

    Fürnstahl, Philipp; Vlachopoulos, Lazaros; Schweizer, Andreas; Fucentese, Sandro F; Koch, Peter P

    2015-08-01

    The accurate reduction of tibial plateau malunions can be challenging without guidance. In this work, we report on a novel technique that combines 3-dimensional computer-assisted planning with patient-specific surgical guides for improving reliability and accuracy of complex intraarticular corrective osteotomies. Preoperative planning based on 3-dimensional bone models was performed to simulate fragment mobilization and reduction in 3 cases. Surgical implementation of the preoperative plan using patient-specific cutting and reduction guides was evaluated; benefits and limitations of the approach were identified and discussed. The preliminary results are encouraging and show that complex, intraarticular corrective osteotomies can be accurately performed with this technique. For selective patients with complex malunions around the tibia plateau, this method might be an attractive option, with the potential to facilitate achieving the most accurate correction possible.

  7. Single-Incision Transumbilical Surgery (SITUS) versus Single-Port Laparoscopic Surgery and conventional laparoscopic surgery: a prospective randomized comparative study of performance with novices in a dry laboratory.

    PubMed

    Schoenthaler, Martin; Avcil, Tuba; Sevcenco, Sabina; Nagele, Udo; Hermann, Thomas E W; Kuehhas, Franklin E; Shariat, Shahrokh F; Frankenschmidt, Alexander; Wetterauer, Ulrich; Miernik, Arkadiusz

    2015-01-01

    To evaluate the Single-Incision Transumbilical Surgery (SITUS) technique as compared to an established laparoendoscopic single-site surgery (LESS) technique (Single-Port Laparoscopic Surgery, SPLS) and conventional laparoscopy (CLS) in a surgical simulator model. Sixty-three medical students without previous laparoscopic experience were randomly assigned to one of the three groups (SITUS, SPLS and CLS). Subjects were asked to perform five standardized tasks of increasing difficulty adopted from the Fundamentals of Laparoscopic Surgery curriculum. Statistical evaluation included task completion times and accuracy. Overall performances of all tasks (except precision cutting) were significantly faster and of higher accuracy in the CLS and SITUS groups than in the SPLS group (p = 0.004 to p < 0.001). CLS and SITUS groups alone showed no significant difference in performance times and accuracy measurements for all tasks (p = 0.048 to p = 0.989). SITUS proved to be a simple, but highly effective technique to overcome restrictions of SPLS. In a surgical simulator model, novices were able to achieve task performances comparable to CLS and did significantly better than using a port-assisted LESS technique such as SPLS. The demonstrated advantages of SITUS may be attributed to a preservation of the basic principles of conventional laparoscopy, such as the use of straight instruments and an adequate degree of triangulation.

  8. [Scanning electron microscopic investigations of cutting edge quality in lamellar keratotomy using the Wavelight femtosecond laser (FS-200) : What influence do spot distance and an additional tunnel have?

    PubMed

    Hammer, T; Höche, T; Heichel, J

    2018-01-01

    Femtosecond lasers (fs-lasers) are established cutting instruments for the creation of LASIK flaps. Previous studies often showed even rougher surfaces after application of fs-laser systems compared to lamellar keratotomy with mechanical microkeratomes. When cutting the cornea with fs-lasers, an intrastromal gas development occurs, which has a potentially negative influence on the cutting quality if the gas cannot be dissipated; therefore, manufacturers have chosen the way of gas assimilation in so-called pockets. The investigated system creates a tunnel which opens under the conjunctiva. The aim of this study was to investigate the effects of a tunnel as well as the influence of different spot distances on the quality of cut surfaces and edges. In this experimental study on freshly enucleated porcine eyes (n = 15), the following cuts were carried out with the FS-200 (Wavelight, Erlangen, Germany): 1. standard setting (spot and line separation 8 µm), 2. with tunnel for gas drainage, 3. without gas-conducting tunnel, 4. with increased spot spacing (spot and line separation 9 μm instead of 8 μm) and 5. with reduced spot spacing (spot and line separation 7 μm instead of 8 μm). Subsequently, scanning electron microscopy (FEI Quanta 650, Hillsboro, OR) of the cut edges and surfaces as well as the gas drain tunnel were performed. The evaluation was based on an established score. The current fs-laser system (200 Hz) is able to create smooth cutting surfaces and sharp edges. The changed density of laser pulses compared to the standard settings with a reduced or increased distance between the pulses, did not achieve any further improvement in the surface quality. The gas-conducting tunnel could be detected by scanning electron microscope. In the case of cutting without a tunnel, roughened surfaces and irregularities on the cutting edges were found. When the FS-200 fs-laser is used, LASIK cuts with very smooth cut surfaces and sharp cutting edges are achieved. This is only valid as long as an additional tunnel with the fs-laser is placed under the conjunctiva. It can be assumed that the resulting gas is effectively drained through this tunnel. The installation of the tunnel represents a new possibility to replace previous techniques of gas assimilation in deeper lying cutting areas.

  9. Karolinska prostatectomy: a robot-assisted laparoscopic radical prostatectomy technique.

    PubMed

    Nilsson, Andreas E; Carlsson, Stefan; Laven, Brett A; Wiklund, N Peter

    2006-01-01

    The last decade has witnessed an increasing trend towards minimally invasive management of prostate cancer, including laparoscopic and, more recently, robot-assisted laparoscopic prostatectomy. Several different laparoscopic approaches have been continuously developed during the last 5 years and it is still unclear which technique yields the best outcome. We present our current technique of robot-assisted laparoscopic radical prostatectomy. The technique described has evolved during the course of >400 robotic prostatectomies performed by the robotic team since the robot-assisted laparoscopic radical prostatectomy program was introduced at Karolinska University Hospital in January 2002. Our procedure comprises several modifications of previously reported ones, and we utilize fewer robotic instruments to reduce costs. An extended posterior dissection is performed to aid in the bladder neck-sparing dissection. In nerve-sparing procedures the vesicles are divided to avoid damage to the erectile nerves. In order to preserve the apical anatomy the dorsal venous complex is incised sharply and is first over-sewn after the apical dissection is completed. Our technique enables a more fluent dissection than previously described robotic techniques. Minimizing changes of instruments and the camera not only cuts costs but also reduces inefficient operating maneuvers, such as switching between 30 degrees and 0 degrees lenses during the procedure. We present a technique which in our hands has achieved excellent functional and oncological results.

  10. Gaussian process regression for tool wear prediction

    NASA Astrophysics Data System (ADS)

    Kong, Dongdong; Chen, Yongjie; Li, Ning

    2018-05-01

    To realize and accelerate the pace of intelligent manufacturing, this paper presents a novel tool wear assessment technique based on the integrated radial basis function based kernel principal component analysis (KPCA_IRBF) and Gaussian process regression (GPR) for real-timely and accurately monitoring the in-process tool wear parameters (flank wear width). The KPCA_IRBF is a kind of new nonlinear dimension-increment technique and firstly proposed for feature fusion. The tool wear predictive value and the corresponding confidence interval are both provided by utilizing the GPR model. Besides, GPR performs better than artificial neural networks (ANN) and support vector machines (SVM) in prediction accuracy since the Gaussian noises can be modeled quantitatively in the GPR model. However, the existence of noises will affect the stability of the confidence interval seriously. In this work, the proposed KPCA_IRBF technique helps to remove the noises and weaken its negative effects so as to make the confidence interval compressed greatly and more smoothed, which is conducive for monitoring the tool wear accurately. Moreover, the selection of kernel parameter in KPCA_IRBF can be easily carried out in a much larger selectable region in comparison with the conventional KPCA_RBF technique, which helps to improve the efficiency of model construction. Ten sets of cutting tests are conducted to validate the effectiveness of the presented tool wear assessment technique. The experimental results show that the in-process flank wear width of tool inserts can be monitored accurately by utilizing the presented tool wear assessment technique which is robust under a variety of cutting conditions. This study lays the foundation for tool wear monitoring in real industrial settings.

  11. An "All-laser" Endothelial Transplant.

    PubMed

    Rossi, Francesca; Canovetti, Annalisa; Malandrini, Alex; Lenzetti, Ivo; Pini, Roberto; Menabuoni, Luca

    2015-07-06

    The "all laser" assisted endothelial keratoplasty is a procedure that is performed with a femtosecond laser used to cut the donor tissue at an intended depth, and a near infrared diode laser to weld the corneal tissue. The proposed technique enables to reach the three main goals in endothelial keratoplasty: a precise control in the thickness of the donor tissue; its easy insertion in the recipient bed and a reduced risk of donor lenticule dislocation. The donor cornea thickness is measured in the surgery room with optical coherence tomography (OCT), in order to correctly design the donor tissue dimensions. A femtosecond laser is used to cut the donor cornea. The recipient eye is prepared by manual stripping of the descemetic membrane. The donor endothelium is inserted into a Busin-injector, the peripheral inner side is stained with a proper chromophore (a water solution of Indocyanine Green) and then it is pulled in the anterior chamber. The transplanted tissue is placed in the final and correct location and then diode laser welding is induced from outside the eyeball. The procedure has been performed on more than 15 patients evidencing an improvement in surgery performances, with a good recovery of visual acuity and a reduced donor lenticule dislocation event.

  12. Technique of laser chromosome welding for chromosome repair and artificial chromosome creation.

    PubMed

    Huang, Yao-Xiong; Li, Lin; Yang, Liu; Zhang, Yi

    2018-04-01

    Here we report a technique of laser chromosome welding that uses a violet pulse laser micro-beam for welding. The technique can integrate any size of a desired chromosome fragment into recipient chromosomes by combining with other techniques of laser chromosome manipulation such as chromosome cutting, moving, and stretching. We demonstrated that our method could perform chromosomal modifications with high precision, speed and ease of use in the absence of restriction enzymes, DNA ligases and DNA polymerases. Unlike the conventional methods such as de novo artificial chromosome synthesis, our method has no limitation on the size of the inserted chromosome fragment. The inserted DNA size can be precisely defined and the processed chromosome can retain its intrinsic structure and integrity. Therefore, our technique provides a high quality alternative approach to directed genetic recombination, and can be used for chromosomal repair, removal of defects and artificial chromosome creation. The technique may also have applicability on the manipulation and extension of large pieces of synthetic DNA.

  13. Cutting electrocautery versus scalpel for surgical incisions: a systematic review and meta-analysis.

    PubMed

    Ismail, Ammar; Abushouk, Abdelrahman Ibrahim; Elmaraezy, Ahmed; Menshawy, Amr; Menshawy, Esraa; Ismail, Mahmoud; Samir, Esraa; Khaled, Anas; Zakarya, Hagar; El-Tonoby, Abdelrahman; Ghanem, Esraa

    2017-12-01

    Although cutting electrocautery can be superior to the scalpel in reducing blood loss and incisional time, several reports associated electrocautery with higher rates of wound infection, impaired healing, and worse cosmesis. We performed this systematic review and meta-analysis to compare cutting electrocautery versus scalpel for surgical incisions. We conducted a computerized literature search of five electronic databases and included all published original studies comparing cutting electrocautery and scalpel surgical incisions. Relevant data were extracted from eligible studies and pooled as odds ratios (ORs) or standardized mean difference (SMD) values in a meta-analysis model, using RevMan and Comprehensive Meta-analysis software. Forty-one studies (36 randomized trials, four observational, and one quasirandom study) were included in the pooled analysis (6422 participants). Compared with the scalpel incision, cutting electrocautery resulted in significantly less blood loss (SMD = -1.16, 95% CI [-1.60 to -0.72]), shorter incisional (SMD = -0.63, 95% CI [-0.96 to -0.29]) and operative times (SMD = -0.59, 95% CI [-1.12 to -0.05]), and lower pain scores (SMD = -0.91, 95% CI [-1.27 to -0.55]) with no significant differences in terms of wound infection rates (OR = 0.92, 95% CI [0.74-1.15]) or overall subjective scar score (SMD = -0.49, 95% CI [-1.72 to 0.75]). Surgical incision using electrocautery can be quicker with less blood loss and postoperative pain scores than the scalpel incision. No statistically significant difference was found between both techniques in terms of postoperative wound complications, hospital stay duration, and wound cosmetic characteristics. Therefore, we recommend routine use of cutting electrocautery for surgical incisions. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. A comparison of mesial molar root canal preparations using two engine-driven instruments and the balanced-force technique.

    PubMed

    Imura, N; Kato, A S; Novo, N F; Hata, G; Uemura, M; Toda, T

    2001-10-01

    The purpose of this study was to compare the effects of two engine-driven, nickel-titanium instrument systems with hand files in the final shape of slight and moderately curved canals. A total of 72 mesial roots of extracted human mandibular molars were divided into three groups: ProFile .04 taper, Pow-R rotary systems, and Flex-R hand-filing technique. The roots were mounted and cross-sectioned at two different horizontal levels using a modified Bramante technique. Pre- and postinstrumented cross-sectional roots were imaged, recorded, and computer analyzed. Results showed that, at the middle third, in almost all groups, there was a tendency of cutting more toward the mesial side with only one exception: Pow-R cut more to the distal side (danger zone) (p < 0.02). At the apical third, Flex-R (p < 0.03) and ProFile (0.001) transported to the mesial side (danger zone) when the curvature increased. When the three techniques were compared analyzing each side and considering the two groups of curvature, at the middle third in the moderately curved-canal group, Flex-R cut statistically more than Pow-R toward the lingual side. The other comparisons showed no statistically significant difference. When the techniques were compared in relation with the degree of curvature, in the apical third, ProFile .04 cut statistically more toward the mesial side in the moderately curved canal group than in the slightly curved canal group. The other comparisons showed no statistically significant difference. Canal preparation time was shorter with hand instrumentation (p < .05) in a few instances.

  15. Nano Mechanical Machining Using AFM Probe

    NASA Astrophysics Data System (ADS)

    Mostofa, Md. Golam

    Complex miniaturized components with high form accuracy will play key roles in the future development of many products, as they provide portability, disposability, lower material consumption in production, low power consumption during operation, lower sample requirements for testing, and higher heat transfer due to their very high surface-to-volume ratio. Given the high market demand for such micro and nano featured components, different manufacturing methods have been developed for their fabrication. Some of the common technologies in micro/nano fabrication are photolithography, electron beam lithography, X-ray lithography and other semiconductor processing techniques. Although these methods are capable of fabricating micro/nano structures with a resolution of less than a few nanometers, some of the shortcomings associated with these methods, such as high production costs for customized products, limited material choices, necessitate the development of other fabricating techniques. Micro/nano mechanical machining, such an atomic force microscope (AFM) probe based nano fabrication, has, therefore, been used to overcome some the major restrictions of the traditional processes. This technique removes material from the workpiece by engaging micro/nano size cutting tool (i.e. AFM probe) and is applicable on a wider range of materials compared to the photolithographic process. In spite of the unique benefits of nano mechanical machining, there are also some challenges with this technique, since the scale is reduced, such as size effects, burr formations, chip adhesions, fragility of tools and tool wear. Moreover, AFM based machining does not have any rotational movement, which makes fabrication of 3D features more difficult. Thus, vibration-assisted machining is introduced into AFM probe based nano mechanical machining to overcome the limitations associated with the conventional AFM probe based scratching method. Vibration-assisted machining reduced the cutting forces and burr formations through intermittent cutting. Combining the AFM probe based machining with vibration-assisted machining enhanced nano mechanical machining processes by improving the accuracy, productivity and surface finishes. In this study, several scratching tests are performed with a single crystal diamond AFM probe to investigate the cutting characteristics and model the ploughing cutting forces. Calibration of the probe for lateral force measurements, which is essential, is also extended through the force balance method. Furthermore, vibration-assisted machining system is developed and applied to fabricate different materials to overcome some of the limitations of the AFM probe based single point nano mechanical machining. The novelty of this study includes the application of vibration-assisted AFM probe based nano scale machining to fabricate micro/nano scale features, calibration of an AFM by considering different factors, and the investigation of the nano scale material removal process from a different perspective.

  16. Novel use of cutting balloon to treat subintimal hematomas during chronic total occlusion interventions.

    PubMed

    Vo, Minh N; Brilakis, Emmanouil S; Grantham, J Aaron

    2018-01-01

    Contemporary chronic total occlusion (CTO) percutaneous coronary interventional (PCI) techniques are increasingly dependent upon dissection and reentry techniques (DARTs) especially for long occluded lesions. DARTs can result in compressive hematomas during CTO interventions and traditional treatment with balloon angioplasty and/or coronary stenting are often suboptimal and may extend the hematoma distally. We describe the novel use of a cutting balloon to "express" these compressive hematomas and restore antegrade coronary blood flow. © 2017 Wiley Periodicals, Inc.

  17. The effect of cutting parameters on the performance of ZTA-MgO cutting tool

    NASA Astrophysics Data System (ADS)

    Ali, A. M.; Hamidon, N. E.; Zaki, N. K. M.; Mokhtar, S.; Azhar, A. Z. A.; Bahar, R.; Ahmad, Z. A.

    2018-01-01

    The effect of cutting parameters on the performances of ZTA-MgO ceramic cutting tool investigated. The aim of this project is to discover the effect of cutting speed and feedrate on the performance of the ZTA-MgO cutting tool via wear and surface roughness measurement. CNC turning machining performed using the cutting speed, Vc range from 354 to 471 m/min and the feed rate, f 0.1, 0.3 and 0.5 mm/rev while the depth of cut, d is kept constant at 0.2 mm. The flank wear, crater wear, and chipping were measured accordingly using optical microscope, Matlab programming and SEM. Surface roughness of machined stainless steel 316L surface were measured using the surface roughness tester (Mitutoyo MTR097-8. The result showing the increment trend of flank wear with increment of cutting speed and feed rate with the lowest value of flank wear, 0.061 mm achieved at Vc = 354 m/min and f = 0.1 mm/rev while the highest flank wear is 0.480 mm at Vc = 471 m/min and f = 0.5 mm/rev. The increasing pattern also observed in the crater wear results. The lowest area of crater wear is 2.2736 mm2 at Vc = 354 m/min and f = 0.1 mm/rev while the highest value is 4.8524 mm2 at Vc = 471 m/min and f = 0.5 mm/rev. As for the surface roughness, the higher the cutting speed, the lower the average roughness (Ra) value. Cutting speed, Vc = 471 m/min with f = 0.1 mm/rev has the lowest value of Ra which is 0.72µm.

  18. Yield and complications in percutaneous renal biopsy. A comparison between ultrasound-guided gun-biopsy and manual techniques in native and transplant kidneys.

    PubMed

    Nyman, R S; Cappelen-Smith, J; al Suhaibani, H; Alfurayh, O; Shakweer, W; Akhtar, M

    1997-05-01

    To compare the yield and complications of ultrasound-guided gun-biopsy and manual Tru-Cut techniques in percutaneous renal biopsy. A total of 448 biopsies were reviewed. They comprised 124 manual and 131 gun-biopsies in native kidneys, and 111 manual and 82 gun-biopsies in transplant kidneys. The gun-biopsies were performed under real-time ultrasound (US) guidance. The manual technique used US mainly for marking the position of the kidney. There was a significantly higher diagnostic yield and fewer complications in the gun-biopsy group. A total of 8 major complications were found, all in the manual group. Provided that the operator is experienced in US scanning, a switch from the manual technique to real-time US-guided gun-biopsy will result in the improvement of diagnostic accuracy together with a reduced risk of complications.

  19. Shaping Cutter Original Profile for Fine-module Ratchet Teeth Cutting

    NASA Astrophysics Data System (ADS)

    Sharkov, O. V.; Koryagin, S. I.; Velikanov, N. L.

    2018-03-01

    The methods for determining geometric characteristics of a theoretical original profile of the cutter for cutting ratchet teeth with a module of 0.3–1.0 mm are considered in the article. Design models describing the shaping process of cutting edges of cutter teeth are developed. Systems of expressions for determining coordinates of the points of front and back edges of cutter teeth; the workpiece angles of rotation during the cutting process; the minimum cutter radius are received. The basic data when using the proposed technique are: radii of circumferences passing through cavities of cutter teeth and external cut teeth; the gradient angle and length of straight section of the front edge of a cut tooth; angles of rotation of the cutter and the workpiece at the moment of shaping.

  20. Optimization of Machining Parameters of Milling Operation by Application of Semi-synthetic oil based Nano cutting Fluids

    NASA Astrophysics Data System (ADS)

    Giri Prasad, M. J.; Abhishek Raaj, A. S.; Rishi Kumar, R.; Gladson, Frank; M, Gautham

    2016-09-01

    The present study is concerned with resolving the problems pertaining to the conventional cutting fluids. Two samples of nano cutting fluids were prepared by dispersing 0.01 vol% of MWCNTs and a mixture of 0.01 vol% of MWCNTs and 0.01 vol% of nano ZnO in the soluble oil. The thermophysical properties such as the kinematic viscosity, density, flash point and the tribological properties of the prepared nano cutting fluid samples were experimentally investigated and were compared with those of plain soluble oil. In addition to this, a milling process was carried by varying the process parameters and by application of different samples of cutting fluids and an attempt was made to determine optimal cutting condition using the Taguchi optimization technique.

  1. Handpiece coolant flow rates and dental cutting.

    PubMed

    von Fraunhofer, J A; Siegel, S C; Feldman, S

    2000-01-01

    High-speed handpieces incorporate water coolant sprays to remove cutting debris and minimize thermal insult to the pulp. Little data exists on optimal coolant flow rates during clinical procedures. This study compared the effect of different coolant flow rates on diamond stone cutting efficiency. Cutting studies were performed on Macor machinable ceramic using a previously developed test regimen--a KaVo high-speed handpiece at a cutting force of 91.5 g (0.9 N). Cutting was performed with round end tapered medium grit diamond stones under cooling water flow rates of 15, 20, 25, 30 and 44 ml/min, with cutting rates determined as the time to transect the 13 mm square cross-section of the Macor bar. Each bur was used for five cuts, with six burs used for each flow rate, for a total of 150 measurements. The data were analyzed by one-way ANOVA with a post hoc Scheffé test. The cutting studies indicated that diamond stone cutting rates increased with higher coolant flow rates over the range of 15-44 ml/min. The data suggest that higher coolant flow rates promote cutting efficiency.

  2. A new method for the continuous production of single dosed controlled release matrix systems based on hot-melt extruded starch: analysis of relevant process parameters and implementation of an in-process control.

    PubMed

    Kipping, Thomas; Rein, Hubert

    2013-05-01

    In the present study, we evaluated a novel processing technique for the continuous production of hot-melt extruded controlled release matrix systems. A cutting technique derived from plastics industry, where it is widely used for cutting of cables and wires was adapted into the production line. Extruded strands were shaped by a rotary fly cutter. Special focus is laid on the development of a process analytical technology by evaluating signals obtained from the servo control of the rotary fly cutter. The intention is to provide a better insight into the production process and to offer the ability to detect small variations in process-variables. A co-rotating twin-screw extruder ZSE 27 HP-PH from Leistritz (Nürnberg, Germany) was used to plasticize the starch; critical extrusion parameters were recorded. Still elastic strands were shaped by a rotary fly-cutter type Dynamat 20 from Metzner (Neu-Ulm, Germany). Properties of the final products were analyzed via digital image analysis to point out critical parameters influencing the quality. Important aspects were uniformity of diameter, height, roundness, weight, and variations in the cutting angle. Stability of the products was measured by friability tests and by determining the crushing strength of the final products. Drug loading studies up to 70% were performed to evaluate the capacity of the matrix and to prove the technological feasibility. Changes in viscosities during API addition were analyzed by a Haake Minilab capillary rheometer. X-ray studies were performed to investigate molecular structures of the matrices. External shapes of the products were highly affected by die-swelling of the melt. Reliable reproducibility concerning uniformity of mass could be achieved even for high production rates (>2500cuts/min). Both mechanical strength and die-swelling of the products could be linked to the ratio of amylose to amylopectin. Formulations containing up to 70% of API could still be processed. Viscosity measurements revealed the plasticizing effect caused by API addition. Dissolution data proved the suitability of extruded starch matrices as a sustained release dosage form. Monitoring of consumed energies during the cutting process could be linked to changes in viscosity. The established PAT system enables the detection of small variations in material properties and can be an important tool to further improve process stability. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Non-Exposure, Device-Assisted Endoscopic Full-thickness Resection.

    PubMed

    Bauder, Markus; Schmidt, Arthur; Caca, Karel

    2016-04-01

    Recent developments have expanded the frontier of interventional endoscopy toward more extended resections following surgical principles. This article presents two new device-assisted techniques for endoscopic full-thickness resection in the upper and lower gastrointestinal tract. Both methods are nonexposure techniques avoiding exposure of gastrointestinal contents to the peritoneal cavity by a "close first-cut later" principle. The full-thickness resection device is a novel over-the-scope device designed for clip-assisted full-thickness resection of colorectal lesions. Endoscopic full-thickness resection of gastric subepithelial tumors can be performed after placing transmural sutures underneath the tumor with a suturing device originally designed for endoscopic antireflux therapy. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Development of low cost custom hybrid microcircuit technology

    NASA Technical Reports Server (NTRS)

    Perkins, K. L.; Licari, J. J.

    1981-01-01

    Selected potentially low cost, alternate packaging and interconnection techniques were developed and implemented in the manufacture of specific NASA/MSFC hardware, and the actual cost savings achieved by their use. The hardware chosen as the test bed for this evaluation ws the hybrids and modules manufactured by Rockwell International fo the MSFC Flight Accelerometer Safety Cut-Off System (FASCOS). Three potentially low cost packaging and interconnection alternates were selected for evaluation. This study was performed in three phases: hardware fabrication and testing, cost comparison, and reliability evaluation.

  5. Optical laser systems at the Linac Coherent Light Source

    DOE PAGES

    Minitti, Michael P.; Robinson, Joseph S.; Coffee, Ryan N.; ...

    2015-04-22

    Ultrafast optical lasers play an essential role in exploiting the unique capabilities of recently commissioned X-ray free-electron laser facilities such as the Linac Coherent Light Source (LCLS). Pump–probe experimental techniques reveal ultrafast dynamics in atomic and molecular processes and reveal new insights in chemistry, biology, material science and high-energy-density physics. This manuscript describes the laser systems and experimental methods that enable cutting-edge optical laser/X-ray pump–probe experiments to be performed at LCLS.

  6. Pyrotechnic shock: A literature survey of the Linear Shaped Charge (LSC)

    NASA Technical Reports Server (NTRS)

    Smith, J. L.

    1984-01-01

    Linear shaped charge (LSC) literature for the past 20 years is reviewed. The following topics are discussed: (1) LSC configuration; (2) LSC usage; (3) LSC induced pyroshock; (4) simulated pyrotechnic testing; (5) actual pyrotechnic testing; (6) data collection methods; (7) data analysis techniques; (8) shock reduction methods; and (9) design criteria. Although no new discoveries have been made in LSC research, charge shapes are improved to allow better cutting performance, testing instrumentation is refined, and some new explosives, for use in LSC, are formulated.

  7. A High-Precision Counter Using the DSP Technique

    DTIC Science & Technology

    2004-09-01

    DSP is not good enough to process all the 1-second samples. The cache memory is also not sufficient to store all the sampling data. So we cut the...sampling number in a cycle is not good enough to achieve an accuracy less than 2×10-11. For this reason, a correlation operation is performed for... not good enough to process all the 1-second samples. The cache memory is also not sufficient to store all the sampling data. We will solve this

  8. Computerized technique for recording board defect data

    Treesearch

    R. Bruce Anderson; R. Edward Thomas; Charles J. Gatchell; Neal D. Bennett; Neal D. Bennett

    1993-01-01

    A computerized technique for recording board defect data has been developed that is faster and more accurate than manual techniques. The lumber database generated by this technique is a necessary input to computer simulation models that estimate potential cutting yields from various lumber breakdown sequences. The technique allows collection of detailed information...

  9. Optimisation Of Cutting Parameters Of Composite Material Laser Cutting Process By Taguchi Method

    NASA Astrophysics Data System (ADS)

    Lokesh, S.; Niresh, J.; Neelakrishnan, S.; Rahul, S. P. Deepak

    2018-03-01

    The aim of this work is to develop a laser cutting process model that can predict the relationship between the process input parameters and resultant surface roughness, kerf width characteristics. The research conduct is based on the Design of Experiment (DOE) analysis. Response Surface Methodology (RSM) is used in this work. It is one of the most practical and most effective techniques to develop a process model. Even though RSM has been used for the optimization of the laser process, this research investigates laser cutting of materials like Composite wood (veneer)to be best circumstances of laser cutting using RSM process. The input parameters evaluated are focal length, power supply and cutting speed, the output responses being kerf width, surface roughness, temperature. To efficiently optimize and customize the kerf width and surface roughness characteristics, a machine laser cutting process model using Taguchi L9 orthogonal methodology was proposed.

  10. Horizontal Planting of Green Ash Cuttings on a Sharkey Clay Site

    Treesearch

    H. E. Kennedy

    1974-01-01

    Horizontally planted green ash cuttings made from 1-0 seedlings sprouted and grew well, as did seedlings and vertically planted cuttings. Ten- and l4-inch cuttings planted 1 and 3 inches deep sprouted best. Two-inch-long cuttings and ones planted 6 inches deep performed unsatisfactorily.

  11. Increasing productivity for the analysis of trace contaminants in food by gas chromatography-mass spectrometry using automated liner exchange, backflushing and heart-cutting.

    PubMed

    David, Frank; Tienpont, Bart; Devos, Christophe; Lerch, Oliver; Sandra, Pat

    2013-10-25

    Laboratories focusing on residue analysis in food are continuously seeking to increase sample throughput by minimizing sample preparation. Generic sample extraction methods such as QuEChERS lack selectivity and consequently extracts are not free from non-volatile material that contaminates the analytical system. Co-extracted matrix constituents interfere with target analytes, even if highly sensitive and selective GC-MS/MS is used. A number of GC approaches are described that can be used to increase laboratory productivity. These techniques include automated inlet liner exchange and column backflushing for preservation of the performance of the analytical system and heart-cutting two-dimensional GC for increasing sensitivity and selectivity. The application of these tools is illustrated by the analysis of pesticides in vegetables and fruits, PCBs in milk powder and coplanar PCBs in fish. It is demonstrated that considerable increase in productivity can be achieved by decreasing instrument down-time, while analytical performance is equal or better compared to conventional trace contaminant analysis. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. LWIR HgCdTe: Innovative detectors in an incumbent technology

    NASA Technical Reports Server (NTRS)

    Tennant, William E.

    1990-01-01

    HgCdTe is the current material of choice for high performance imagers operating at relatively high temperatures. Its lack of technological maturity compared with silicon and wide-band gap III-V compounds is more than offset by its outstanding IR sensitivity and by the relatively benign effect of its materials defects. This latter property has allowed non-equilibrium growth techniques, metal oxide chemical vapor deposition (MOCVD) and molecular beam epitaxy (MBE), to produce device quality long wavelength infrared (LWIR) HgCdTe even on common substrates like GaAs and GaAs/Si. Detector performance in these exotic materials structures is comparable in many ways with devices in equilibrium-grown material. Lifetimes are similar. RoA values at 77K as high as several hundred have been seen in HgCdTe/GaAs/Si with 9.5 micron cut-off wavelength. HgCdTe/GaAs layers with approx. 15 micron cut-off wavelengths have given average 77K RoAs of greater than 2. Hybrid focal plane arrays have been evaluated with excellent operability.

  13. A Simple Model of Pulsed Ejector Thrust Augmentation

    NASA Technical Reports Server (NTRS)

    Wilson, Jack; Deloof, Richard L. (Technical Monitor)

    2003-01-01

    A simple model of thrust augmentation from a pulsed source is described. In the model it is assumed that the flow into the ejector is quasi-steady, and can be calculated using potential flow techniques. The velocity of the flow is related to the speed of the starting vortex ring formed by the jet. The vortex ring properties are obtained from the slug model, knowing the jet diameter, speed and slug length. The model, when combined with experimental results, predicts an optimum ejector radius for thrust augmentation. Data on pulsed ejector performance for comparison with the model was obtained using a shrouded Hartmann-Sprenger tube as the pulsed jet source. A statistical experiment, in which ejector length, diameter, and nose radius were independent parameters, was performed at four different frequencies. These frequencies corresponded to four different slug length to diameter ratios, two below cut-off, and two above. Comparison of the model with the experimental data showed reasonable agreement. Maximum pulsed thrust augmentation is shown to occur for a pulsed source with slug length to diameter ratio equal to the cut-off value.

  14. Evaluation of Process Performance for Sustainable Hard Machining

    NASA Astrophysics Data System (ADS)

    Rotella, Giovanna; Umbrello, Domenico; , Oscar W. Dillon, Jr.; Jawahir, I. S.

    This paper aims to evaluate the sustainability performance of machining operation of through-hardening steel, AISI 52100, taking into account the impact of the material removal process in its various aspects. Experiments were performed for dry and cryogenic cutting conditions using chamfered cubic boron nitride (CBN) tool inserts at varying cutting conditions (cutting speed and feed rate). Cutting forces, mechanical power, tool wear, white layer thickness, surface roughness and residual stresses were investigated in order to evaluate the effects of extreme in-process cooling on the machined surface. The results indicate that cryogenic cooling has the potential to be used for surface integrity enhancement for improved product life and more sustainable functional performance.

  15. Accuracy in planar cutting of bones: an ISO-based evaluation.

    PubMed

    Cartiaux, Olivier; Paul, Laurent; Docquier, Pierre-Louis; Francq, Bernard G; Raucent, Benoît; Dombre, Etienne; Banse, Xavier

    2009-03-01

    Computer- and robot-assisted technologies are capable of improving the accuracy of planar cutting in orthopaedic surgery. This study is a first step toward formulating and validating a new evaluation methodology for planar bone cutting, based on the standards from the International Organization for Standardization. Our experimental test bed consisted of a purely geometrical model of the cutting process around a simulated bone. Cuts were performed at three levels of surgical assistance: unassisted, computer-assisted and robot-assisted. We measured three parameters of the standard ISO1101:2004: flatness, parallelism and location of the cut plane. The location was the most relevant parameter for assessing cutting errors. The three levels of assistance were easily distinguished using the location parameter. Our ISO methodology employs the location to obtain all information about translational and rotational cutting errors. Location may be used on any osseous structure to compare the performance of existing assistance technologies.

  16. Method for Fabricating Composite Structures Using Pultrusion Processing

    NASA Technical Reports Server (NTRS)

    Farley, Gary L. (Inventor)

    2000-01-01

    A method for fabricating composite structures at a low-cost, moderate-to-high production rate. A first embodiment of the method includes employing a continuous press forming fabrication process. A second embodiment of the method includes employing a pultrusion process for obtaining composite structures. The methods include coating yarns with matrix material, weaving the yarn into fabric to produce a continuous fabric supply and feeding multiple layers of net-shaped fabrics having optimally oriented fibers into a debulking tool to form an undebulked preform. The continuous press forming fabrication process includes partially debulking the preform, cutting the partially debulked preform and debulking the partially debulked preform to form a net-shape. An electron-beam or similar technique then cures the structure. The pultrusion fabric process includes feeding the undebulked preform into a heated die and gradually debulking the undebulked preform. The undebulked preform in the heated die changes dimension until a desired cross-sectional dimension is achieved. This process further includes obtaining a net-shaped infiltrated uncured preform, cutting the uncured preform to a desired length and electron-beam curing (or similar technique) the uncured preform. These fabrication methods produce superior structures formed at higher production rates, resulting in lower cost and high structural performance.

  17. Video segmentation for post-production

    NASA Astrophysics Data System (ADS)

    Wills, Ciaran

    2001-12-01

    Specialist post-production is an industry that has much to gain from the application of content-based video analysis techniques. However the types of material handled in specialist post-production, such as television commercials, pop music videos and special effects are quite different in nature from the typical broadcast material which many video analysis techniques are designed to work with; shots are short and highly dynamic, and the transitions are often novel or ambiguous. We address the problem of scene change detection and develop a new algorithm which tackles some of the common aspects of post-production material that cause difficulties for past algorithms, such as illumination changes and jump cuts. Operating in the compressed domain on Motion JPEG compressed video, our algorithm detects cuts and fades by analyzing each JPEG macroblock in the context of its temporal and spatial neighbors. Analyzing the DCT coefficients directly we can extract the mean color of a block and an approximate detail level. We can also perform an approximated cross-correlation between two blocks. The algorithm is part of a set of tools being developed to work with an automated asset management system designed specifically for use in post-production facilities.

  18. Method for Fabricating Composite Structures Using Continuous Press Forming

    NASA Technical Reports Server (NTRS)

    Farley, Gary L. (Inventor)

    1997-01-01

    A method for fabricating composite structures at a low-cost. moderate-to-high production rate. A first embodiment of the method includes employing a continuous press forming fabrication process. A second embodiment of the method includes employing a pultrusion process for obtaining composite structures. The methods include coating yarns with matrix material, weaving the yarn into fabric to produce a continuous fabric supply and feeding multiple layers of net-shaped fabrics having optimally oriented fibers into a debulking tool to form an undebulked preform. The continuous press forming fabrication process includes partially debulking the preform, cutting the partially debulked preform and debulking the partially debulked preform to form a net-shape. An electron-beam or similar technique then cures the structure. The pultrusion fabric process includes feeding the undebulked preform into a heated die and gradually debulking the undebulked preform. The undebulked preform in the heated die changes dimension until a desired cross-sectional dimension is achieved. This process further includes obtaining a net-shaped infiltrated uncured preform, cutting the uncured preform to a desired length and electron-beam curing (or similar technique) the uncured preform. These fabrication methods produce superior structures formed at higher production rates. resulting in lower cost and high structural performance.

  19. Method for Fabricating Composite Structures Using Pultrusion Processing

    NASA Technical Reports Server (NTRS)

    Farley, Gary L. (Inventor)

    2000-01-01

    A method for fabricating composite structures at a low-cost, moderate-to-high production rate. A first embodiment of the method includes employing a continuous press forming fabrication process. A second embodiment of the method includes employing a pultrusion process for obtaining composite structures. The methods include coating yarns with matrix material, weaving the yarn into fabric to produce a continuous fabric supply and feeding multiple layers of net-shaped fabrics having optimally oriented fibers into a debulking tool to form an undebulked preform. The continuous press forming fabrication process includes partially debulking the preform, cutting the partially debulked preform and debulking the partially debulked preform to form a netshape. An electron-beam or similar technique then cures the structure. The pultrusion fabric process includes feeding the undebulked preform into a heated die and gradually debulking the undebulked preform. The undebulked preform in the heated die changes dimension until a desired cross-sectional dimension is achieved. This process further includes obtaining a net-shaped infiltrated uncured preform, cutting the uncured preform to a desired length and electronbeam curing (or similar technique) the uncured preform. These fabrication methods produce superior structures formed at higher production rates, resulting in lower cost and high structural performance.

  20. Experimental study on the healing process following laser welding of the cornea.

    PubMed

    Rossi, Francesca; Pini, Roberto; Menabuoni, Luca; Mencucci, Rita; Menchini, Ugo; Ambrosini, Stefano; Vannelli, Gabriella

    2005-01-01

    An experimental study evaluating the application of laser welding of the cornea and the subsequent healing process is presented. The welding of corneal wounds is achieved after staining the cut walls with a solution of the chromophore indocyanine green, and irradiating them with a diode laser (810 nm) operating at low power (60 to 90 mW). The result is a localized heating of the cut, inducing controlled welding of the stromal collagen. In order to optimize this technique and to study the healing process, experimental tests, simulating cataract surgery and penetrating keratoplasty, were performed on rabbits: conventional and laser-induced suturing of corneal wounds were thus compared. A follow-up study 7 to 90 days after surgery was carried out by means of objective and histological examinations, in order to optimize the welding technique and to investigate the subsequent healing process. The analyses of the laser-welded corneas evidenced a faster and more effective restoration of the architecture of the stroma. No thermal damage of the welded stroma was detected, nor were there foreign body reactions or other inflammatory processes. Copyright 2005 Society of Photo-Optical Instrumentation Engineers.

  1. Laser speckle technique to study the effect of chemical pre-treatment on the quality of minimally processed apples

    NASA Astrophysics Data System (ADS)

    Minz, Preeti D.; Nirala, A. K.

    2016-04-01

    In the present study, the laser speckle technique has been used for the quality evaluation of chemically treated cut apples. Chemical pre-treatment includes 1% (w/v) solution of citric acid (CA), sodium chloride (SC), and a combination of CA and sodium chloride (CS). The variation in weight loss, respiration rate, total soluble solids (TSS), titratable acidity (TA), and absorbance of chemically treated cut apples stored at 5 °C was monitored for 11 d. The speckle grain size was calculated by an autocovariance method from the speckled images of freshly cut chemically treated apples. The effect of chemicals on TSS and the TA content variation of the cut apples were well correlated to the linear speckle grain size. Circular degree of polarization confirms the presence of a small scatterer and hence Rayleigh diffusion region. For all the treated cut apples, a decrease in the concentration of small particles nearly after the mid-period of storage results in the fast decay of circular degree of polarization. For non-invasive and fast analysis of the chemical constituent of fruits during minimal processing, the laser speckle can be practically used in the food industry.

  2. Histologic effects of different technologies for dissection in endoscopic surgery: Nd:YAG laser, high frequency and water-jet.

    PubMed

    Schurr, M O; Wehrmann, M; Kunert, W; Melzer, A; Lirici, M M; Trapp, R; Kanehira, E; Buess, G

    1994-01-01

    Precise cutting combined with reliable coagulation of the margins of the lesion is an important requirement for dissection techniques in endoscopic surgery. These requirements are met by the two most common ancillary energy sources applied for endoscopic dissection today, electrosurgery and "thermal lasers", mostly the Nd:YAG. For the comparison of the histological effects of monopolar and bipolar high frequency with the Nd:YAG laser an experimental in vitro and in vivo study has been performed. In order to evaluate the advantages of non thermal dissection for endoscopic procedures, a water jet cutting system was included in the in vitro study. In parenchymatous tissue the water jet was found to be the least traumatic technique, followed by bipolar high frequency, laser and monopolar high frequency. The water jet was not applicable for intestinal dissection since uncontrolled bloating of the rectal wall with uncontrolled disruption of the tissue layers occurred. A general disadvantage is that secure haemostasis in the line of incision is hard to achieve. In the microscopic comparison of the shape of the incision, the Nd:YAG laser produced the smoothest lesions with well-defined margins. The monopolar technique was more often associated with irregular and sometimes fissured margins. These results were confirmed in the in vivo part of the study (Transanal Endoscopic Microsurgery).

  3. A high performance sensor for triaxial cutting force measurement in turning.

    PubMed

    Zhao, You; Zhao, Yulong; Liang, Songbo; Zhou, Guanwu

    2015-04-03

    This paper presents a high performance triaxial cutting force sensor with excellent accuracy, favorable natural frequency and acceptable cross-interference for high speed turning process. Octagonal ring is selected as sensitive element of the designed sensor, which is drawn inspiration from ring theory. A novel structure of two mutual-perpendicular octagonal rings is proposed and three Wheatstone full bridge circuits are specially organized in order to obtain triaxial cutting force components and restrain cross-interference. Firstly, the newly developed sensor is tested in static calibration; test results indicate that the sensor possesses outstanding accuracy in the range of 0.38%-0.83%. Secondly, impacting modal tests are conducted to identify the natural frequencies of the sensor in triaxial directions (i.e., 1147 Hz, 1122 Hz and 2035 Hz), which implies that the devised sensor can be used for cutting force measurement in a high speed lathe when the spindle speed does not exceed 17,205 rev/min in continuous cutting condition. Finally, an application of the sensor in turning process is operated to show its performance for real-time cutting force measurement; the measured cutting forces demonstrate a good accordance with the variation of cutting parameters. Thus, the developed sensor possesses perfect properties and it gains great potential for real-time cutting force measurement in turning.

  4. A High Performance Sensor for Triaxial Cutting Force Measurement in Turning

    PubMed Central

    Zhao, You; Zhao, Yulong; Liang, Songbo; Zhou, Guanwu

    2015-01-01

    This paper presents a high performance triaxial cutting force sensor with excellent accuracy, favorable natural frequency and acceptable cross-interference for high speed turning process. Octagonal ring is selected as sensitive element of the designed sensor, which is drawn inspiration from ring theory. A novel structure of two mutual-perpendicular octagonal rings is proposed and three Wheatstone full bridge circuits are specially organized in order to obtain triaxial cutting force components and restrain cross-interference. Firstly, the newly developed sensor is tested in static calibration; test results indicate that the sensor possesses outstanding accuracy in the range of 0.38%–0.83%. Secondly, impacting modal tests are conducted to identify the natural frequencies of the sensor in triaxial directions (i.e., 1147 Hz, 1122 Hz and 2035 Hz), which implies that the devised sensor can be used for cutting force measurement in a high speed lathe when the spindle speed does not exceed 17,205 rev/min in continuous cutting condition. Finally, an application of the sensor in turning process is operated to show its performance for real-time cutting force measurement; the measured cutting forces demonstrate a good accordance with the variation of cutting parameters. Thus, the developed sensor possesses perfect properties and it gains great potential for real-time cutting force measurement in turning. PMID:25855035

  5. Relative abundance and species richness of cerambycid beetles in partial cut and uncut bottomland hardwood forests

    USGS Publications Warehouse

    Newell, P.; King, S.

    2009-01-01

    Partial cutting techniques are increasingly advocated and used to create habitat for priority wildlife. However, partial cutting may or may not benefit species dependent on deadwood; harvesting can supplement coarse woody debris in the form of logging slash, but standing dead trees may be targeted for removal. We sampled cerambycid beetles during the spring and summer of 2006 and 2007 with canopy malaise traps in 1- and 2-year-old partial cut and uncut bottomland hardwood forests of Louisiana. We captured a total of 4195 cerambycid beetles representing 65 species. Relative abundance was higher in recent partial cuts than in uncut controls and with more dead trees in a plot. Total species richness and species composition were not different between treatments. The results suggest partial cuts with logging slash left on site increase the abundance of cerambycid beetles in the first few years after partial cutting and that both partial cuts and uncut forest should be included in the bottomland hardwood forest landscape.

  6. Digital modeling of end-mill cutting tools for FEM applications from the active cutting contour

    NASA Astrophysics Data System (ADS)

    Salguero, Jorge; Marcos, M.; Batista, M.; Gómez, A.; Mayuet, P.; Bienvenido, R.

    2012-04-01

    A very current technique in the research field of machining by material removal is the use of simulations using the Finite Element Method (FEM). Nevertheless, and although is widely used in processes that allows approximations to orthogonal cutting, such as shaping, is scarcely used in more complexes processes, such as milling. This fact is due principally to the complex geometry of the cutting tools in these processes, and the need to realize the studi es in an oblique cutting configuration. This paper shows a methodology for the geometrical characterization of commercial endmill cutting tools, by the extraction of the cutting tool contour, making use of optical metrology, and using this geometry to model the active cutting zone with a 3D CAD software. This model is easily exportable to different CAD formats, such as IGES or STEP, and importable from FEM software, where is possible to study the behavior in service of the same ones.

  7. CT acquisition technique and quantitative analysis of the lung parenchyma: variability and corrections

    NASA Astrophysics Data System (ADS)

    Zheng, Bin; Leader, J. K.; Coxson, Harvey O.; Scuirba, Frank C.; Fuhrman, Carl R.; Balkan, Arzu; Weissfeld, Joel L.; Maitz, Glenn S.; Gur, David

    2006-03-01

    The fraction of lung voxels below a pixel value "cut-off" has been correlated with pathologic estimates of emphysema. We performed a "standard" quantitative CT (QCT) lung analysis using a -950 HU cut-off to determine the volume fraction of emphysema (below the cut-off) and a "corrected" QCT analysis after removing small group (5 and 10 pixels) of connected pixels ("blobs") below the cut-off. CT examinations two dataset of 15 subjects each with a range of visible emphysema and pulmonary obstruction were acquired at "low-dose and conventional dose reconstructed using a high-spatial frequency kernel at 2.5 mm section thickness for the same subject. The "blob" size (i.e., connected-pixels) removed was inversely related to the computed fraction of emphysema. The slopes of emphysema fraction versus blob size were 0.013, 0.009, and 0.005 for subjects with both no emphysema and no pulmonary obstruction, moderate emphysema and pulmonary obstruction, and severe emphysema and severe pulmonary obstruction, respectively. The slopes of emphysema fraction versus blob size were 0.008 and 0.006 for low-dose and conventional CT examinations, respectively. The small blobs of pixels removed are most likely CT image artifacts and do not represent actual emphysema. The magnitude of the blob correction was appropriately associated with COPD severity. The blob correction appears to be applicable to QCT analysis in low-dose and conventional CT exams.

  8. Transient beam oscillation with a highly dynamic scanner for laser beam fusion cutting

    NASA Astrophysics Data System (ADS)

    Goppold, Cindy; Pinder, Thomas; Herwig, Patrick

    2016-02-01

    Sheet metals with thicknesses >8 mm have a distinct cutting performance. The free choice of the optical configuration composed of fiber diameter, collimation, and focal length offers many opportunities to influence the static beam geometry. Previous analysis points out the limitations of this method in the thick section area. Within the present study, an experimental investigation of fiber laser fusion cutting of 12 mm stainless steel was performed by means of dynamical beam oscillation. Two standard optical setups are combined with a highly dynamic galvano-driven scanner that achieves frequencies up to 4 kHz. Dependencies of the scanner parameter, the optical circumstances, and the conventional cutting parameters are discussed. The aim is to characterize the capabilities and challenges of the dynamic beam shaping in comparison to the state-of-the-art static beam shaping. Thus, the trials are evaluated by quality criteria of the cut edge as surface roughness and burr height, the feed rate, and the cut kerf geometry. The investigation emphasizes promising procedural possibilities for improvements of the cutting performance in the case of fiber laser fusion cutting of thick stainless steel by means of the application of a highly dynamic scanner.

  9. Diagnostic accuracy of fluorescence microlymphography for detecting limb lymphedema.

    PubMed

    Keo, H H; Husmann, M; Groechenig, E; Willenberg, T; Gretener, S B

    2015-04-01

    Fluorescence microlymphography (FML) is a minimally invasive technique for visualization of the cutaneous lymphatic network. The aim of the study was to assess the accuracy and safety of FML in patients with unilateral lymphedema. This was a cross sectional study. Patients with unilateral leg swelling were assessed and compared with the unaffected contralateral limb. FML was performed in all index legs and the contralateral leg by injecting 0.1 mL of fluorescein isothiocyanate (FITC)-labeled dextran intradermally in both limbs at the same level. The most prominent swelling of the affected limb was the anatomical reference. The spread of the dye in the lymphatic capillaries of the skin was measured in all dimensions by epiluminator intravital microscopy and the maximum dye spread value 10 min after injection was used for statistical analysis. The contralateral leg served as control. Test accuracy and receiver operator characteristic (ROC) analysis was performed to assess threshold values that best predict lymphedema. Between March 2008 and February 2014 seventy patients with unilateral chronic leg swelling were clinically diagnosed with lymphedema. The median age was 45 (IQR 27-56) years. Of those, 46 (65.7%) were female and 71.4% had primary and 28.6% secondary lymphedema. Sensitivity, specificity, positive and negative likelihood ratio, and positive and negative predictive value were 94.3%, 78.6%, 4.40, 0.07, 81.5%, and 93.2% for the 12 mm cut off level and 91.4%, 85.7%, 6.40, 0.10, 86.5%, and 90.9% for the 14 mm cut off level, respectively. The area under the ROC curve was 0.89 (95% CI: 0.83-0.95). No major adverse events were observed. FML is an almost atraumatic and safe technique for detecting lymphedema in patients with leg swelling. In this series the greatest accuracy was observed at a cut off level of ≥14 mm maximum spread. Copyright © 2015 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  10. Testing Of Choiced Ceramics Cutting Tools At Irregular Interrupted Cut

    NASA Astrophysics Data System (ADS)

    Kyncl, Ladislav; Malotová, Šárka; Nováček, Pavel; Nicielnik, Henryk; Šoková, Dagmar; Hemžský, Pavel; Pitela, David; Holubjak, Jozef

    2015-12-01

    This article discusses the test of removable ceramic cutting inserts during machining irregular interrupted cut. Tests were performed on a lathe, with the preparation which simulated us the interrupted cut. By changing the number of plates mounted in a preparation it simulate us a regular or irregular interrupted cut. When with four plates it was regular interrupted cut, the remaining three variants were already irregular cut. It was examined whether it will have the irregular interrupted cutting effect on the insert and possibly how it will change life of inserts during irregular interrupted cut (variable delay between shocks).

  11. Incising the thick retrolental fibrovascular tissue with a hooked sclerotome in persistent hyperplastic primary vitreous.

    PubMed

    Shiraki, K; Moriwaki, M; Kohno, T; Yanagihara, N; Miki, T

    1999-01-01

    A technique for incising thick retrolental fibrovascular tissue and extensive cyclitic membrane is reported in a case of anterior persistent hyperplastic primary vitreous. A membranectomy was performed in a 1-month-old post-lensectomy baby via a limbal approach. A sclerotome tip was hooked to cut through an extremely thick fibrovascular tissue by rotating the sclerotome by its grip. Sutherland microscissors (Grieshaber, Switzerland) and a vitrectomy cutter were used for further membranectomy. The baby was followed-up until age 18 months. A total of 3 membranectomy sessions were required because of rapid cyclitic membrane formation, severe centripetal retraction of the membrane on the ciliary processes, and posterior synechia. Thorough membranectomy and cutting the iris edge maintained a clear pupillary area during the 13-month postoperative period. Extremely thick retrolental fibrovascular tissue is a challenging condition that can be dealt with by delicate instrumentation.

  12. OARSI-OMERACT definition of relevant radiological progression in hip/knee osteoarthritis.

    PubMed

    Ornetti, P; Brandt, K; Hellio-Le Graverand, M-P; Hochberg, M; Hunter, D J; Kloppenburg, M; Lane, N; Maillefert, J-F; Mazzuca, S A; Spector, T; Utard-Wlerick, G; Vignon, E; Dougados, M

    2009-07-01

    Joint space width (JSW) evaluated in millimeters on plain X-rays is the currently optimal recognized technique to evaluate osteoarthritis (OA) structural progression. Data obtained can be presented at the group level (e.g., mean+/-standard deviation of the changes). Such presentation makes difficult the interpretation of the clinical relevance of the reported results. Therefore, a presentation at the individual level (e.g., % progressors) seems more attractive but requires to determining a cut-off. Several methodologies have been proposed to define cut-offs in JSW: arbitrary chosen cut-off, cut-off based on the validity to predict a relevant end-point such as the requirement of total articular replacement or cut-off based on the measurement error such as smallest detectable difference (SDD). The objective of this OARSI-OMERACT initiative was to define a cut-off evaluated in millimeters on plain X-rays above which a change in JSW could be considered as relevant in patients with hip and knee OA. The first step consisted in a systematic literature research performed using Medline database up to July 2007 to obtain all manuscripts published between 1990 and 2007 reporting a cut-off value in JSW evaluated in millimeters at either the knee or hip level. The second step consisted in a consensus based on the best knowledge of the 11 experts with the support of the available evidence. Among the 506 articles selected by the search, 47 articles reported cut-off of JSW in millimeters. There was a broad heterogeneity in cut-off values, whatever the methodologies or the OA localization considered (e.g., from 0.12 to 0.84 mm and from 0.22 to 0.78 mm for Knee (seven studies) and hip (seven studies), respectively when considering the data obtained based on the reliability). Based on the data extracted in the literature, the expert committee proposed a definition of relevant change in JSW based on plain X-rays, on an absolute change of JSW in millimeters and on the measurement error e.g., calculation of the SDD using the Bland and Altman technique. The results of the analysis of JSW should be expressed in terms of a dichotomous variable (e.g., progressors yes/no): a patient with a change in JSW during the study over such SDD will fulfill the definition of "progressor". Moreover, the pilot study aimed at evaluating the measurement error should be designed to reflect the different characteristics of the primary study in which the analysis of the radiological findings will be based on (patient's characteristics, centers characteristics, readers). This initiative based on both an Evidence Based Medicine (Systematic Literature Research) and Expert Opinion approach resulted in a proposal of definition of relevant radiological progression in OA to be used as end-point in clinical trials and also recommendations on the conduct of the reliability study allowing such definition.

  13. Tumour thickness as a determinant of nodal metastasis in oral tongue carcinoma.

    PubMed

    Wang, Kejia; Veivers, David

    2017-09-01

    Tumour thickness is a strong predictor for cervical node involvement in oral cavity squamous cell carcinomas (SCCs), with a recent meta-analysis concluding a 4-mm optimal prognostic cut-off point. No consensus has been reached for the tumour thickness cut-off for oral tongue SCCs. A retrospective review of prospectively collected data from 112 patients by the Northern Sydney Cancer Centre (Australia) with primary oral tongue SCC was conducted. Tumour thickness was measured by standard histopathological techniques and cervical node involvement was determined either from neck dissection histopathology or by clinical and radiological follow-up. Neck dissection was performed in 78 patients (70%). Tumour thickness was a significant predictor of cervical node disease (P < 0.01), with a median tumour thickness of 5.5 mm. Cervical node metastasis rates for tumours <2, 2-3.9 and ≥4 mm thick were 10%, 42.1% and 46.5%, respectively. The rate of cervical node metastasis was significantly higher for patients with tumours thicker than a cut-off of 2 mm (odds ratio: 7.53, P < 0.01). A 4-mm thickness cut-off was also statistically significant (P < 0.05); however, the odds ratio was smaller at 2.52. Despite some previous evidence for a 4-mm tumour thickness cut-off in oral tongue SCCs, thinner tumours (2-3.9 mm) can also have a propensity for cervical node metastasis. Patients in this category require close monitoring for regional recurrence if they do not have a neck dissection. © 2016 Royal Australasian College of Surgeons.

  14. Endoscopic removal of over-the-scope clips: Clinical experience with a bipolar cutting device

    PubMed Central

    Meier, Benjamin; Caca, Karel; Schmidt, Arthur

    2016-01-01

    Background Over-the-scope clips (OTSCs) are increasingly used for the closure of perforations/fistulae, hemostasis and endoscopic full-thickness resection (FTRD system). When OTSC-associated complications occur or re-therapy at the OTSC site is needed, OTSC removal may be indicated. An experimental study in an animal model and a case series have shown good results for OTSC removal with a bipolar cutting device. We present a larger clinical study using this device. Methods Data of all consecutive patients with indication for OTSC removal were collected and analyzed retrospectively. OTSCs were cut at two opposing sites using a bipolar grasping device to apply short direct current impulses. OTSC fragments were extracted with a standard forceps and a cap at the tip of the endoscope to avoid tissue damage. Results Between December 2012 and February 2016 a total of 42 OTSC removals in the upper (n = 25) and lower (n = 17) gastrointestinal tract have been performed at our department. Overall technical success, defined as cutting the OTSC at two opposing sites and extraction of both fragments, was achieved in 92.9% (39/42) of all cases. Successful fragmentation of the OTSC was achieved in 97.6% (41/42). Minor bleedings were rare and could be managed endoscopically in all cases. There were no perforations and no major or delayed bleedings. Conclusion Endoscopic OTSC removal with a bipolar cutting device is feasible, effective and safe. This technique can be applied in the upper and lower gastrointestinal tract. PMID:28588877

  15. 30 CFR 717.14 - Backfilling and grading of road cuts, mine entry area cuts, and other surface work areas.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 3 2011-07-01 2011-07-01 false Backfilling and grading of road cuts, mine entry area cuts, and other surface work areas. 717.14 Section 717.14 Mineral Resources OFFICE OF SURFACE... MINING GENERAL PERFORMANCE STANDARDS § 717.14 Backfilling and grading of road cuts, mine entry area cuts...

  16. CPU-GPU mixed implementation of virtual node method for real-time interactive cutting of deformable objects using OpenCL.

    PubMed

    Jia, Shiyu; Zhang, Weizhong; Yu, Xiaokang; Pan, Zhenkuan

    2015-09-01

    Surgical simulators need to simulate interactive cutting of deformable objects in real time. The goal of this work was to design an interactive cutting algorithm that eliminates traditional cutting state classification and can work simultaneously with real-time GPU-accelerated deformation without affecting its numerical stability. A modified virtual node method for cutting is proposed. Deformable object is modeled as a real tetrahedral mesh embedded in a virtual tetrahedral mesh, and the former is used for graphics rendering and collision, while the latter is used for deformation. Cutting algorithm first subdivides real tetrahedrons to eliminate all face and edge intersections, then splits faces, edges and vertices along cutting tool trajectory to form cut surfaces. Next virtual tetrahedrons containing more than one connected real tetrahedral fragments are duplicated, and connectivity between virtual tetrahedrons is updated. Finally, embedding relationship between real and virtual tetrahedral meshes is updated. Co-rotational linear finite element method is used for deformation. Cutting and collision are processed by CPU, while deformation is carried out by GPU using OpenCL. Efficiency of GPU-accelerated deformation algorithm was tested using block models with varying numbers of tetrahedrons. Effectiveness of our cutting algorithm under multiple cuts and self-intersecting cuts was tested using a block model and a cylinder model. Cutting of a more complex liver model was performed, and detailed performance characteristics of cutting, deformation and collision were measured and analyzed. Our cutting algorithm can produce continuous cut surfaces when traditional minimal element creation algorithm fails. Our GPU-accelerated deformation algorithm remains stable with constant time step under multiple arbitrary cuts and works on both NVIDIA and AMD GPUs. GPU-CPU speed ratio can be as high as 10 for models with 80,000 tetrahedrons. Forty to sixty percent real-time performance and 100-200 Hz simulation rate are achieved for the liver model with 3,101 tetrahedrons. Major bottlenecks for simulation efficiency are cutting, collision processing and CPU-GPU data transfer. Future work needs to improve on these areas.

  17. Optimization of CO2 laser cutting parameters on Austenitic type Stainless steel sheet

    NASA Astrophysics Data System (ADS)

    Parthiban, A.; Sathish, S.; Chandrasekaran, M.; Ravikumar, R.

    2017-03-01

    Thin AISI 316L stainless steel sheet widely used in sheet metal processing industries for specific applications. CO2 laser cutting is one of the most popular sheet metal cutting processes for cutting of sheets in different profile. In present work various cutting parameters such as laser power (2000 watts-4000 watts), cutting speed (3500mm/min - 5500 mm/min) and assist gas pressure (0.7 Mpa-0.9Mpa) for cutting of AISI 316L 2mm thickness stainless sheet. This experimentation was conducted based on Box-Behenken design. The aim of this work is to develop a mathematical model kerf width for straight and curved profile through response surface methodology. The developed mathematical models for straight and curved profile have been compared. The Quadratic models have the best agreement with experimental data, and also the shape of the profile a substantial role in achieving to minimize the kerf width. Finally the numerical optimization technique has been used to find out best optimum laser cutting parameter for both straight and curved profile cut.

  18. Performance of TcI/TcVI/TcII Chagas-Flow ATE-IgG2a for universal and genotype-specific serodiagnosis of Trypanosoma cruzi infection

    PubMed Central

    Alessio, Glaucia Diniz; de Araújo, Fernanda Fortes; Côrtes, Denise Fonseca; Sales Júnior, Policarpo Ademar; Lima, Daniela Cristina; Gomes, Matheus de Souza; do Amaral, Laurence Rodrigues; Xavier, Marcelo Antônio Pascoal; Teixeira-Carvalho, Andréa; Martins-Filho, Olindo Assis; de Lana, Marta

    2017-01-01

    Distinct Trypanosoma cruzi genotypes have been considered relevant for patient management and therapeutic response of Chagas disease. However, typing strategies for genotype-specific serodiagnosis of Chagas disease are still unavailable and requires standardization for practical application. In this study, an innovative TcI/TcVI/TcII Chagas Flow ATE-IgG2a technique was developed with applicability for universal and genotype-specific diagnosis of T. cruzi infection. For this purpose, the reactivity of serum samples (percentage of positive fluorescent parasites-PPFP) obtained from mice chronically infected with TcI/Colombiana, TcVI/CL or TcII/Y strain as well as non-infected controls were determined using amastigote-AMA, trypomastigote-TRYPO and epimastigote-EPI in parallel batches of TcI, TcVI and TcII target antigens. Data demonstrated that “α-TcII-TRYPO/1:500, cut-off/PPFP = 20%” presented an excellent performance for universal diagnosis of T. cruzi infection (AUC = 1.0, Se and Sp = 100%). The combined set of attributes “α-TcI-TRYPO/1:4,000, cut-off/PPFP = 50%”, “α-TcII-AMA/1:1,000, cut-off/PPFP = 40%” and “α-TcVI-EPI/1:1,000, cut-off/PPFP = 45%” showed good performance to segregate infections with TcI/Colombiana, TcVI/CL or TcII/Y strain. Overall, hosts infected with TcI/Colombiana and TcII/Y strains displayed opposite patterns of reactivity with “α-TcI TRYPO” and “α-TcII AMA”. Hosts infected with TcVI/CL strain showed a typical interweaved distribution pattern. The method presented a good performance for genotype-specific diagnosis, with global accuracy of 69% when the population/prototype scenario include TcI, TcVI and TcII infections and 94% when comprise only TcI and TcII infections. This study also proposes a receiver operating reactivity panel, providing a feasible tool to classify serum samples from hosts infected with distinct T. cruzi genotypes, supporting the potential of this method for universal and genotype-specific diagnosis of T. cruzi infection. PMID:28333926

  19. Analysis of the learning curve for pre-cut corneal specimens in preparation for lamellar transplantation: a prospective, single-centre, consecutive case series prepared at the Lions New South Wales Eye Bank.

    PubMed

    Martin, Aifric Isabel; Devasahayam, Rajnesh; Hodge, Christopher; Cooper, Simon; Sutton, Gerard L

    2017-09-01

    This study is the first paper to establish a learning curve by a single technician. Preparation of pre-cut corneal endothelial grafts commenced at Lions New South Wales Eye Bank in December 2014. The primary objective of this study was to review the safety and reliability of the preparation method during the first year of production. This is a hospital-based, prospective case series. There were 234 consecutive donor corneal lenticules. Donor lenticules were prepared by a single operator using a linear cutting microkeratome. Immediately prior to cutting, central corneal thickness values were recorded. Measurements of the corneal bed were taken immediately following lenticule preparation. Outcomes were separated by blade sizes, and intended thickness was compared to actual thickness for each setting. Early specimens were compared to later ones to assess for a learning curve within the technique. The main parameter measured is the mean difference from intended lamellar cut thickness. The mean final cut thickness was 122.36 ± 20.35 μm, and the mean difference from intended cut was 30.17 ± 37.45 μm. No significant difference was found between results achieved with early specimens versus those achieved with later specimens (P = 0.425). Thin, reproducible endothelial grafts can routinely be produced by trained technicians at their respective eye banks without significant concerns for an extended learning curve. This service can reduce perioperative surgical complexity, required surgical paraphernalia and theatre times. The consistent preparation of single-pass, ultrathin pre-cut corneas may have additional advantages for surgeons seeking to introduce lamellar techniques. © 2017 Royal Australian and New Zealand College of Ophthalmologists.

  20. A Performance Comparison Study of Uncoated and TiAlN Coated Carbide End Mill on Machining of the Al-35Zn Alloy

    NASA Astrophysics Data System (ADS)

    Bayraktar, S.; Hekimoglu, A. P.; Turgut, Y.; Haciosmanoglu, M.

    2018-01-01

    In this study, Al-35Zn alloy was produced by permanent mold casting. To investigate the cutting performance of uncoated and TiAlN coated carbide end mills on this alloy, a series of tests were carried out in the CNC vertical machining center at a constant cutting speed, feed rate and depth of cut. The results obtained from the tests showed that uncoated carbide end mill have lower cutting force and surface roughness than TiAlN coated carbide end mill. These observations are discussed in terms of the alloys properties, cutting tool surfaces, and friction and wear behavior between the cutting tool and the material.

  1. A logic-based method for integer programming

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hooker, J.; Natraj, N.R.

    1994-12-31

    We propose a logic-based approach to integer programming that replaces traditional branch-and-cut techniques with logical analogs. Integer variables are regarded as atomic propositions. The constraints give rise to logical formulas that are analogous to separating cuts. No continuous relaxation is used. Rather, the cuts are selected so that they can be easily solved as a discrete relaxation. (In fact, defining a relaxation and generating cuts are best seen as the same problem.) We experiment with relaxations that have a k-tree structure and can be solved by nonserial dynamic programming. We also present logic-based analogs of facet-defining cuts, Chv{acute a}tal rank,more » etc. We conclude with some preliminary computational results.« less

  2. Laser assisted machining: a state of art review

    NASA Astrophysics Data System (ADS)

    Punugupati, Gurabvaiah; Kandi, Kishore Kumar; Bose, P. S. C.; Rao, C. S. P.

    2016-09-01

    Difficult-to-cut materials have increasing demand in aerospace and automobile industries due to their high yield stress, high strength to weight ratio, high toughness, high wear resistance, high creep, high corrosion resistivity, ability to retain high strength at high temperature, etc. The machinability of these advanced materials, using conventional methods of machining is typical due to the high temperature and pressure at the cutting zone and tool and properties such as low thermal conductivity, high cutting forces and cutting temperatures makes the materials difficult to machine. Laser assisted machining (LAM) is a new and innovative technique for machining the difficult-to-cut materials. This paper deals with a review on the advances in lasers, tools and the mechanism of machining using LAM and their effects.

  3. A review of technology and safety aspects of erbium lasers in dentistry.

    PubMed

    Clarkson, D M

    2001-01-01

    This article reviews aspects of the probable mechanisms used by erbium dental lasers for cutting dentine and enamel, describes key issues of the risk of temperature elevation and speed of cutting relative to conventional techniques and looks at issues concerned with the safety of lasers.

  4. Path Planning For A Class Of Cutting Operations

    NASA Astrophysics Data System (ADS)

    Tavora, Jose

    1989-03-01

    Optimizing processing time in some contour-cutting operations requires solving the so-called no-load path problem. This problem is formulated and an approximate resolution method (based on heuristic search techniques) is described. Results for real-life instances (clothing layouts in the apparel industry) are presented and evaluated.

  5. High-Speed Edge Trimming of CFRP and Online Monitoring of Performance of Router Tools Using Acoustic Emission

    PubMed Central

    Prakash, Rangasamy; Krishnaraj, Vijayan; Zitoune, Redouane; Sheikh-Ahmad, Jamal

    2016-01-01

    Carbon fiber reinforced polymers (CFRPs) have found wide-ranging applications in numerous industrial fields such as aerospace, automotive, and shipping industries due to their excellent mechanical properties that lead to enhanced functional performance. In this paper, an experimental study on edge trimming of CFRP was done with various cutting conditions and different geometry of tools such as helical-, fluted-, and burr-type tools. The investigation involves the measurement of cutting forces for the different machining conditions and its effect on the surface quality of the trimmed edges. The modern cutting tools (router tools or burr tools) selected for machining CFRPs, have complex geometries in cutting edges and surfaces, and therefore a traditional method of direct tool wear evaluation is not applicable. An acoustic emission (AE) sensing was employed for on-line monitoring of the performance of router tools to determine the relationship between AE signal and length of machining for different kinds of geometry of tools. The investigation showed that the router tool with a flat cutting edge has better performance by generating lower cutting force and better surface finish with no delamination on trimmed edges. The mathematical modeling for the prediction of cutting forces was also done using Artificial Neural Network and Regression Analysis. PMID:28773919

  6. New developments in surface technology and prototyping

    NASA Astrophysics Data System (ADS)

    Himmer, Thomas; Beyer, Eckhard

    2003-03-01

    Novel lightweight applications in the automotive and aircraft industries require advanced materials and techniques for surface protection as well as direct and rapid manufacturing of the related components and tools. The manufacturing processes presented in this paper are based on multiple additive and subtractive technologies such as laser cutting, laser welding, direct laser metal deposition, laser/plasma hybrid spraying technique or CNC milling. The process chain is similar to layer-based Rapid Prototyping Techniques. In the first step, the 3D CAD geometry is sliced into layers by a specially developed software. These slices are cut by high speed laser cutting and then joined together. In this way laminated tools or parts are built. To improve surface quality and to increase wear resistance a CNC machining center is used. The system consists of a CNC milling machine, in which a 3 kW Nd:YAG laser, a coaxial powder nozzle and a digitizing system are integrated. Using a new laser/plasma hybrid spraying technique, coatings can be deposited onto parts for surface protection. The layers show a low porosity and high adhesion strength, the thickness is up to 0.3 mm, and the lower effort for preliminary surface preparation reduces time and costs of the whole process.

  7. Approximation methods for stochastic petri nets

    NASA Technical Reports Server (NTRS)

    Jungnitz, Hauke Joerg

    1992-01-01

    Stochastic Marked Graphs are a concurrent decision free formalism provided with a powerful synchronization mechanism generalizing conventional Fork Join Queueing Networks. In some particular cases the analysis of the throughput can be done analytically. Otherwise the analysis suffers from the classical state explosion problem. Embedded in the divide and conquer paradigm, approximation techniques are introduced for the analysis of stochastic marked graphs and Macroplace/Macrotransition-nets (MPMT-nets), a new subclass introduced herein. MPMT-nets are a subclass of Petri nets that allow limited choice, concurrency and sharing of resources. The modeling power of MPMT is much larger than that of marked graphs, e.g., MPMT-nets can model manufacturing flow lines with unreliable machines and dataflow graphs where choice and synchronization occur. The basic idea leads to the notion of a cut to split the original net system into two subnets. The cuts lead to two aggregated net systems where one of the subnets is reduced to a single transition. A further reduction leads to a basic skeleton. The generalization of the idea leads to multiple cuts, where single cuts can be applied recursively leading to a hierarchical decomposition. Based on the decomposition, a response time approximation technique for the performance analysis is introduced. Also, delay equivalence, which has previously been introduced in the context of marked graphs by Woodside et al., Marie's method and flow equivalent aggregation are applied to the aggregated net systems. The experimental results show that response time approximation converges quickly and shows reasonable accuracy in most cases. The convergence of Marie's method and flow equivalent aggregation are applied to the aggregated net systems. The experimental results show that response time approximation converges quickly and shows reasonable accuracy in most cases. The convergence of Marie's is slower, but the accuracy is generally better. Delay equivalence often fails to converge, while flow equivalent aggregation can lead to potentially bad results if a strong dependence of the mean completion time on the interarrival process exists.

  8. Ultrasound-guided synovial Tru-cut biopsy: indications, technique, and outcome in 111 cases.

    PubMed

    Sitt, Jacqueline C M; Griffith, James F; Lai, Fernand M; Hui, Mamie; Chiu, K H; Lee, Ryan K L; Ng, Alex W H; Leung, Jason

    2017-05-01

    To investigate the diagnostic performance of ultrasound-guided synovial biopsy. Clinical notes, pathology and microbiology reports, ultrasound and other imaging studies of 100 patients who underwent 111 ultrasound-guided synovial biopsies were reviewed. Biopsies were compared with the final clinical diagnosis established after synovectomy (n = 43) or clinical/imaging follow-up (n = 57) (mean 30 months). Other than a single vasovagal episode, no complication of synovial biopsy was encountered. One hundred and seven (96 %) of the 111 biopsies yielded synovium histologically. Pathology ± microbiology findings for these 107 conclusive biopsies comprised synovial tumour (n = 30, 28 %), synovial infection (n = 18, 17 %), synovial inflammation (n = 45, 42 %), including gouty arthritis (n = 3), and no abnormality (n = 14, 13 %). The accuracy, sensitivity, and specificity of synovial biopsy was 99 %, 97 %, and 100 % for synovial tumour; 100 %, 100 %, and 100 % for native joint infection; and 78 %, 45 %, and 100 % for prosthetic joint infection. False-negative synovial biopsy did not seem to be related to antibiotic therapy. Ultrasound-guided Tru-cut synovial biopsy is a safe and reliable technique with a high diagnostic yield for diagnosing synovial tumour and also, most likely, for joint infection. Regarding joint infection, synovial biopsy of native joints seems to have a higher diagnostic yield than that for infected prosthetic joints. • Ultrasound-guided Tru-cut synovial biopsy has high accuracy (99 %) for diagnosing synovial tumour. • It has good accuracy, sensitivity, and high specificity for diagnosis of joint infection. • Synovial biopsy of native joints works better than biopsy of prosthetic joints. • A negative synovial biopsy culture from a native joint largely excludes septic arthritis. • Ultrasound-guided Tru-cut synovial biopsy is a safe and well-tolerated procedure.

  9. Wire blade development for Fixed Abrasive Slicing Technique (FAST) slicing

    NASA Technical Reports Server (NTRS)

    Khattak, C. P.; Schmid, F.; Smith, M. B.

    1982-01-01

    A low cost, effective slicing method is essential to make ingot technology viable for photovoltaics in terrestrial applications. The fixed abrasive slicing technique (FAST) combines the advantages of the three commercially developed techniques. In its development stage FAST demonstrated cutting effectiveness of 10 cm and 15 cm diameter workpieces. Wire blade development is still the critical element for commercialization of FAST technology. Both impregnated and electroplated wire blades have been developed; techniques have been developed to fix diamonds only in the cutting edge of the wire. Electroplated wires show the most near term promise and this approach is emphasized. With plated wires it has been possible to control the size and shape of the electroplating, it is expected that this feature reduces kerf and prolongs the life of the wirepack.

  10. In vitro fenestration of aortic stent-grafts: implications of puncture methods for in situ fenestration durability.

    PubMed

    Riga, Celia V; Bicknell, Colin D; Basra, Melvinder; Hamady, Mohamad; Cheshire, Nicholas J W

    2013-08-01

    To investigate the quality of stent-graft fenestrations created in vitro using different needle puncture and balloon dilation angles in different commercial endografts. Fenestrations were made in a standardized fashion in 3 different endograft types: Talent monofilament twill woven polyester, Zenith multifilament tubular woven polyester, and Endofit thin-walled expanded polytetrafluoroethylene (PTFE). Punctures were made at 30°, 60°, and 90° angles using a 20-G needle and dilated using 6-mm standard and 7-mm cutting balloons; at least 6 fenestrations were made at each angle with standard balloons and at least 6 with cutting balloons. The 137 fenestrations were examined under light microscopy; quantitative and qualitative digital image analysis was performed to determine size, shape, and fenestration quality. PTFE grafts were easier to puncture/dilate, resulting in larger, elliptical fenestrations with overall better quality than the Dacron grafts; however, the puncture/dilation angle made an impact on the shape and quality of fenestrations. A significant number of fabric tears were observed in PTFE fabric at <90° puncture/dilation angles compared to Dacron grafts. In Dacron grafts, fenestration quality was significantly higher with 90° puncture/dilation angles (higher in Talent grafts). Cutting balloon use resulted in significantly more fabric tears and poor quality fenestrations in all graft types. Different endografts behave significantly differently when fenestrations are fashioned. Optimum puncture/dilation is important when considering in vivo fenestration techniques. Improvements in instrumentation, materials, and techniques are required to make this a reliable and reproducible endovascular option.

  11. Method for 3D noncontact measurements of cut trees package area

    NASA Astrophysics Data System (ADS)

    Knyaz, Vladimir A.; Vizilter, Yuri V.

    2001-02-01

    Progress in imaging sensors and computers create the background for numerous 3D imaging application for wide variety of manufacturing activity. Many demands for automated precise measurements are in wood branch of industry. One of them is the accurate volume definition for cut trees carried on the truck. The key point for volume estimation is determination of the front area of the cut tree package. To eliminate slow and inaccurate manual measurements being now in practice the experimental system for automated non-contact wood measurements is developed. The system includes two non-metric CCD video cameras, PC as central processing unit, frame grabbers and original software for image processing and 3D measurements. The proposed method of measurement is based on capturing the stereo pair of front of trees package and performing the image orthotranformation into the front plane. This technique allows to process transformed image for circle shapes recognition and calculating their area. The metric characteristics of the system are provided by special camera calibration procedure. The paper presents the developed method of 3D measurements, describes the hardware used for image acquisition and the software realized the developed algorithms, gives the productivity and precision characteristics of the system.

  12. GSFC Cutting Edge Avionics Technologies for Spacecraft

    NASA Technical Reports Server (NTRS)

    Luers, Philip J.; Culver, Harry L.; Plante, Jeannette

    1998-01-01

    With the launch of NASA's first fiber optic bus on SAMPEX in 1992, GSFC has ushered in an era of new technology development and insertion into flight programs. Predating such programs the Lewis and Clark missions and the New Millenium Program, GSFC has spearheaded the drive to use cutting edge technologies on spacecraft for three reasons: to enable next generation Space and Earth Science, to shorten spacecraft development schedules, and to reduce the cost of NASA missions. The technologies developed have addressed three focus areas: standard interface components, high performance processing, and high-density packaging techniques enabling lower cost systems. To realize the benefits of standard interface components GSFC has developed and utilized radiation hardened/tolerant devices such as PCI target ASICs, Parallel Fiber Optic Data Bus terminals, MIL-STD-1773 and AS1773 transceivers, and Essential Services Node. High performance processing has been the focus of the Mongoose I and Mongoose V rad-hard 32-bit processor programs as well as the SMEX-Lite Computation Hub. High-density packaging techniques have resulted in 3-D stack DRAM packages and Chip-On-Board processes. Lower cost systems have been demonstrated by judiciously using all of our technology developments to enable "plug and play" scalable architectures. The paper will present a survey of development and insertion experiences for the above technologies, as well as future plans to enable more "better, faster, cheaper" spacecraft. Details of ongoing GSFC programs such as Ultra-Low Power electronics, Rad-Hard FPGAs, PCI master ASICs, and Next Generation Mongoose processors.

  13. Beyond the Snapshot.

    ERIC Educational Resources Information Center

    Smith, Lloyd

    1979-01-01

    Presents some inventive darkroom techniques which can lead students to new interests in designing creative images. These techniques include easel manipulation, image blending, paper negatives, vignette, vaseline smear, cut strip, flop negative, or combinations of these. Each technique is illustrated by a student photograph. (Author/SJL)

  14. Special-effect edit detection using VideoTrails: a comparison with existing techniques

    NASA Astrophysics Data System (ADS)

    Kobla, Vikrant; DeMenthon, Daniel; Doermann, David S.

    1998-12-01

    Video segmentation plays an integral role in many multimedia applications, such as digital libraries, content management systems, and various other video browsing, indexing, and retrieval systems. Many algorithms for segmentation of video have appeared within the past few years. Most of these algorithms perform well on cuts, but yield poor performance on gradual transitions or special effects edits. A complete video segmentation system must also achieve good performance on special effect edit detection. In this paper, we discuss the performance of our Video Trails-based algorithms, with other existing special effect edit-detection algorithms within the literature. Results from experiments testing for the ability to detect edits from TV programs, ranging from commercials to news magazine programs, including diverse special effect edits, which we have introduced.

  15. Machines employing a hot gas jet to cut metals and nonmetallic materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Polyaev, V.M.; Aleksandrenkov, V.P.

    1995-07-01

    The flame-cutting of metals is a basic materials-processing operation performed in the course of machine-building and, in some sectors (shipbuilding, aircraft construction, petrochemicals) it is the most important operation. In addition, this method of cutting remains the main operation performed in the processing of scrap metal. The importance of it has occasioned the development of a wide range of cutting tools within just the last decade. Not surprisingly, VNIIavtogen-mash (the All-Union Scientific Research Institute of Machinery for the Gas Welding and Cutting of Metals) is the leading designer of metal-cutting tools in this country. The problem of efficiently cutting metalsmore » is gaining in importance and will continue to do so in coming years in connection with the conversion of military hardware to other uses, the decommissioning of old and obsolete equipment, and utilization of the enormous reserves of scrap in this country. There will thus be a significant increase in the amounts of existing high-alloy steels, nonferrous metals and their alloys, and composites that require cutting. A wide range of cutters is available for the gas-flame cutting of metals, Liquid fuels based on petroleum products are promising from the viewpoint of energy efficiency and performance. The operation of a new generation of cutters, referred to as thermo-gas jet cutters, is based on the principle of the destructive action of a hot, fast-moving, chemically active jet on the material to be cut.« less

  16. Analysis of cutting force signals by wavelet packet transform for surface roughness monitoring in CNC turning

    NASA Astrophysics Data System (ADS)

    García Plaza, E.; Núñez López, P. J.

    2018-01-01

    On-line monitoring of surface finish in machining processes has proven to be a substantial advancement over traditional post-process quality control techniques by reducing inspection times and costs and by avoiding the manufacture of defective products. This study applied techniques for processing cutting force signals based on the wavelet packet transform (WPT) method for the monitoring of surface finish in computer numerical control (CNC) turning operations. The behaviour of 40 mother wavelets was analysed using three techniques: global packet analysis (G-WPT), and the application of two packet reduction criteria: maximum energy (E-WPT) and maximum entropy (SE-WPT). The optimum signal decomposition level (Lj) was determined to eliminate noise and to obtain information correlated to surface finish. The results obtained with the G-WPT method provided an in-depth analysis of cutting force signals, and frequency ranges and signal characteristics were correlated to surface finish with excellent results in the accuracy and reliability of the predictive models. The radial and tangential cutting force components at low frequency provided most of the information for the monitoring of surface finish. The E-WPT and SE-WPT packet reduction criteria substantially reduced signal processing time, but at the expense of discarding packets with relevant information, which impoverished the results. The G-WPT method was observed to be an ideal procedure for processing cutting force signals applied to the real-time monitoring of surface finish, and was estimated to be highly accurate and reliable at a low analytical-computational cost.

  17. Impact of the number of image planes of real-time three-dimensional echocardiography on the accuracy of left atrial and ventricular volume measurements.

    PubMed

    Li, Fang; Wang, Qian; Yao, Gui Hua; Zhang, Peng Fei; Ge, Zhi Ming; Zhang, Mei; Zhang, Yun

    2008-01-01

    Real-time three-dimensional (3D) echocardiography (RT-3DE) has emerged as a new technique in measuring left atrial and ventricular volume. However, the impact of cutting planes of RT-3DE on the accuracy of volume measurement in patients with a normal or enlarged heart is still unknown. We enrolled 30 normal subjects (control group) and 30 patients with heart failure (patient group). RT-3DE was performed to measure maximal volume of the left atrium (LAVmax) and left ventricular end-diastole volume (LVEDV) with 2-, 4-, 8- and 16-cutting planes, compared with cardiac magnetic resonance imaging (CMRI). In both groups, LAVmax by RT-3DE using 2- and 4-cutting planes was significantly underestimated (mean difference: -10.4 +/- 16.6 mL, p = 0.001 and -8.8 +/- 14.2 mL, p = 0.002 in the control group and -13.4 +/- 19.6 mL, p = 0.001 and -11.2 +/- 17.5 mL, p = 0.001 in the patient group, respectively). These differences became nonsignificant when 8- and 16-cutting planes were adopted (mean difference: -2.1 +/- 7.6 mL and -1.9 +/- 7.4 mL in the control group and -2.7 +/- 8.4 mL and -2.2 +/- 8.3 mL in the patient group, respectively). The agreement for LVEDV was acceptable when 4- or more cutting planes were used in the control group and when 8- or 16-cutting planes were used in the patient group. The time expense for data analysis of LAVmax with 8-image planes was only 7 +/- 4 min in the control group and 6 +/- 5 min in the patient group, almost halving that of the 16-image planes. Similarly, 4- and 8-cutting planes were required for an accurate measurement of LVEDV in the control and patient groups, respectively. In conclusion, RT-3DE with 8-cutting planes is both accurate and timesaving for measurement of LAVmax and LVEDV in patients with normal or enlarged left atria and ventricles.

  18. Imaging, cutting, and collecting instrument and method

    DOEpatents

    Tench, Robert J.; Siekhaus, Wigbert J.; Balooch, Mehdi; Balhorn, Rodney L.; Allen, Michael J.

    1995-01-01

    Instrumentation and techniques to image small objects, such as but not limited to individual human chromosomes, with nanometer resolution, to cut-off identified parts of such objects, to move around and manipulate such cut-off parts on the substrate on which they are being imaged to predetermined locations on the substrate, and to remove the cut-off parts from the substrate. This is accomplished using an atomic force microscope (AFM) and by modification of the conventional cantilever stylus assembly of an AFM, such that plural cantilevers are used with either sharp-tips or knife-edges thereon. In addition, the invention can be utilized for measuring hardness of materials.

  19. On the Cutting Performance of Segmented Diamond Blades when Dry-Cutting Concrete

    PubMed Central

    Martynenko, V.; Martínez Krahmer, D.; Benítez, A.; Genovese, G.

    2018-01-01

    The objective of the present study is to analyze and compare the cutting performance of segmented diamond blades when dry-cutting concrete. A cutting criteria is proposed to characterize the wear of the blades by measuring the variation of the external diameter and the weight loss of the blade. The results exhibit the cutting blade SB-A, which has twice the density of diamonds and large contact area, exhibits less wear even though the material removal rate is higher compared with the other two cutting blades. Additionally, the surface topography of the different blades is evaluated to examine the impact of wear depending on the surface profile and the distribution of the diamonds in the blade’s matrix. Large number of diamonds pull-out are found in blades type SB-C, which additionally shows the worst wear resistant capability. As a conclusion, the cutting efficiency of the blade is found to be related to the density of embedded diamonds and the type of the surface profile of the cutting blade after reaching the stop criteria. PMID:29425125

  20. On the Cutting Performance of Segmented Diamond Blades when Dry-Cutting Concrete.

    PubMed

    Sánchez Egea, A J; Martynenko, V; Martínez Krahmer, D; López de Lacalle, L N; Benítez, A; Genovese, G

    2018-02-09

    The objective of the present study is to analyze and compare the cutting performance of segmented diamond blades when dry-cutting concrete. A cutting criteria is proposed to characterize the wear of the blades by measuring the variation of the external diameter and the weight loss of the blade. The results exhibit the cutting blade SB-A, which has twice the density of diamonds and large contact area, exhibits less wear even though the material removal rate is higher compared with the other two cutting blades. Additionally, the surface topography of the different blades is evaluated to examine the impact of wear depending on the surface profile and the distribution of the diamonds in the blade's matrix. Large number of diamonds pull-out are found in blades type SB-C, which additionally shows the worst wear resistant capability. As a conclusion, the cutting efficiency of the blade is found to be related to the density of embedded diamonds and the type of the surface profile of the cutting blade after reaching the stop criteria.

  1. Condition monitoring of turning process using infrared thermography technique - An experimental approach

    NASA Astrophysics Data System (ADS)

    Prasad, Balla Srinivasa; Prabha, K. Aruna; Kumar, P. V. S. Ganesh

    2017-03-01

    In metal cutting machining, major factors that affect the cutting tool life are machine tool vibrations, tool tip/chip temperature and surface roughness along with machining parameters like cutting speed, feed rate, depth of cut, tool geometry, etc., so it becomes important for the manufacturing industry to find the suitable levels of process parameters for obtaining maintaining tool life. Heat generation in cutting was always a main topic to be studied in machining. Recent advancement in signal processing and information technology has resulted in the use of multiple sensors for development of the effective monitoring of tool condition monitoring systems with improved accuracy. From a process improvement point of view, it is definitely more advantageous to proactively monitor quality directly in the process instead of the product, so that the consequences of a defective part can be minimized or even eliminated. In the present work, a real time process monitoring method is explored using multiple sensors. It focuses on the development of a test bed for monitoring the tool condition in turning of AISI 316L steel by using both coated and uncoated carbide inserts. Proposed tool condition monitoring (TCM) is evaluated in the high speed turning using multiple sensors such as Laser Doppler vibrometer and infrared thermography technique. The results indicate the feasibility of using the dominant frequency of the vibration signals for the monitoring of high speed turning operations along with temperatures gradient. A possible correlation is identified in both regular and irregular cutting tool wear. While cutting speed and feed rate proved to be influential parameter on the depicted temperatures and depth of cut to be less influential. Generally, it is observed that lower heat and temperatures are generated when coated inserts are employed. It is found that cutting temperatures are gradually increased as edge wear and deformation developed.

  2. Evaluation of a self-equilibrium cutting strategy for the contour method of residual stress measurement

    DOE PAGES

    Muránsky, Ondrej; Hamelin, Cory J.; Hosseinzadeh, F.; ...

    2017-04-06

    An assessment of cutting-induced plasticity (CIP) is performed, by finite element (FE) prediction of the plastic strain accumulation along the cut tip when the EDM wire sections the NeT TG4 weld benchmark specimen along two cutting directions. The first direction corresponds to a conventional (C) cutting strategy, whereby the EDM wire cuts through the thickness of the weld specimen and travels in a direction transverse to the weld. The second direction corresponds to a self-equilibrating cutting (SE) strategy, whereby the EDM wire cuts across the transverse direction of the weld specimens and travels through the thickness of the plate. Themore » cutting thus progresses simultaneously through the compression-tension-compression regions of present weld residual stress (WRS) field. This type of cutting strategy is believed to minimize the CIP by minimising residual stress redistribution during cutting, due to stress equilibration across the sectioned material. The simulated cutting procedures are conducted under a range of clamping conditions to assess whether mechanical restraint has a primary or secondary influence on CIP accumulation. Both predictions of CIP and the resultant back-calculated WRS demonstrate that (i) mechanical restraint is the primary variable influencing CIP development, and (ii) under no circumstance does a self-equilibrating cutting strategy perform significantly better than a conventional cutting approach. Furthermore, the reason that self-equilibrating cuts are not effective is illustrated by calculating the Mode I (K I) stress intensity factor (SIF) along the cut tip, and correlating trends in K I to CIP development.« less

  3. Evaluation of a self-equilibrium cutting strategy for the contour method of residual stress measurement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muránsky, Ondrej; Hamelin, Cory J.; Hosseinzadeh, F.

    An assessment of cutting-induced plasticity (CIP) is performed, by finite element (FE) prediction of the plastic strain accumulation along the cut tip when the EDM wire sections the NeT TG4 weld benchmark specimen along two cutting directions. The first direction corresponds to a conventional (C) cutting strategy, whereby the EDM wire cuts through the thickness of the weld specimen and travels in a direction transverse to the weld. The second direction corresponds to a self-equilibrating cutting (SE) strategy, whereby the EDM wire cuts across the transverse direction of the weld specimens and travels through the thickness of the plate. Themore » cutting thus progresses simultaneously through the compression-tension-compression regions of present weld residual stress (WRS) field. This type of cutting strategy is believed to minimize the CIP by minimising residual stress redistribution during cutting, due to stress equilibration across the sectioned material. The simulated cutting procedures are conducted under a range of clamping conditions to assess whether mechanical restraint has a primary or secondary influence on CIP accumulation. Both predictions of CIP and the resultant back-calculated WRS demonstrate that (i) mechanical restraint is the primary variable influencing CIP development, and (ii) under no circumstance does a self-equilibrating cutting strategy perform significantly better than a conventional cutting approach. Furthermore, the reason that self-equilibrating cuts are not effective is illustrated by calculating the Mode I (K I) stress intensity factor (SIF) along the cut tip, and correlating trends in K I to CIP development.« less

  4. Teaching three-dimensional surgical concepts of inguinal hernia in a time-effective manner using a two-dimensional paper-cut.

    PubMed

    Mann, B D; Seidman, A; Haley, T; Sachdeva, A K

    1997-06-01

    Because inguinal hernia repair is difficult for third-year students to comprehend, a 2-dimensional paper-cut was developed to teach the concepts of inguinal hernia in a time-effective manner before students' observation of herniorrhaphy in the operating room. Using Adobe Illustrator 5.5 for MacIntosh, a 2-dimensional inexpensively printed paper-cut was created to allow students to perform their own simulated hernia repair before observing surgery. The exercise was performed using a no.15 scalpel or an iris scissors and was evaluated by comparing 10-question pre-tests and post-tests. Seventy-five students performed the exercise, most completing it within 15 minutes. The mean pre-test score was 7.4/10 and the mean post-test score was 9.1/10. Students performing the paper-cut reported better understanding when observing actual herniorrhaphy. A 2-dimensional paper-cut ("surgical origami") may be a time-effective method to prepare students for the observation of hernia repair.

  5. Piezosurgery in head and neck oncological and reconstructive surgery: personal experience on 127 cases

    PubMed Central

    Crosetti, E; Battiston, B; Succo, G

    2009-01-01

    Summary Piezoelectric bone surgery, known simply as piezosurgery, is a new technique of osteotomy and osteoplasty, which requires the use of microvibrations of ultrasonic frequency scalpels. The principle of piezosurgery is ultrasonic transduction, obtained by piezoelectric ceramic contraction and expansion. The vibrations thus obtained are amplified and transferred onto the insert of a drill which, when rapidly applied, with slight pressure, upon the bony tissue, results, in the presence of irrigation with physiological solution, in the cavitation phenomenon, with a mechanical cutting effect, exclusively on mineralized tissues. Personal experience with the use of piezosurgery in head and neck oncological and reconstructive surgery is relatively recent, having been developed in 2002-2006, and, so far, involves 127 cases; preliminary results are interesting and improving in the, hopefully, developmental phases of inserts with specific geometrics on account of the characteristics of the various aspects of surgical ENT operations. Furthermore, with piezoelectric surgery it has been possible to perform precise osteotomy lines, micrometric and curvilinear with absolute confidence, particularly in close proximity to the vessels and nerves and other important facial structures (dura mater). There can be no doubt, since this is a new cutting method, that piezosurgery involves a different learning curve compared to other techniques, requiring obstacles of a psychological nature to be overcome as well as that concerning surgical expertise. Given the numbers of cases treated and the relative power of this instrument, analysis of complications, intra-operative time (which would appear, on average, to be 20% longer) and, therefore, morbility, shows interesting potentiality of the technique. This new ultrasound cutting method will, no doubt, in the future, be increasingly used in ENT surgery, particularly with improvements in power and geometry of the inserts, with possible applications also in neurosurgery, paediatric surgery and orthopedics, branches in which a selective action upon the mineralized tissues is of fundamental importance. PMID:19609375

  6. Machining process influence on the chip form and surface roughness by neuro-fuzzy technique

    NASA Astrophysics Data System (ADS)

    Anicic, Obrad; Jović, Srđan; Aksić, Danilo; Skulić, Aleksandar; Nedić, Bogdan

    2017-04-01

    The main aim of the study was to analyze the influence of six machining parameters on the chip shape formation and surface roughness as well during turning of Steel 30CrNiMo8. Three components of cutting forces were used as inputs together with cutting speed, feed rate, and depth of cut. It is crucial for the engineers to use optimal machining parameters to get the best results or to high control of the machining process. Therefore, there is need to find the machining parameters for the optimal procedure of the machining process. Adaptive neuro-fuzzy inference system (ANFIS) was used to estimate the inputs influence on the chip shape formation and surface roughness. According to the results, the cutting force in direction of the depth of cut has the highest influence on the chip form. The testing error for the cutting force in direction of the depth of cut has testing error 0.2562. This cutting force determines the depth of cut. According to the results, the depth of cut has the highest influence on the surface roughness. Also the depth of cut has the highest influence on the surface roughness. The testing error for the cutting force in direction of the depth of cut has testing error 5.2753. Generally the depth of cut and the cutting force which provides the depth of cut are the most dominant factors for chip forms and surface roughness. Any small changes in depth of cut or in cutting force which provide the depth of cut could drastically affect the chip form or surface roughness of the working material.

  7. Full-band error control and crack-free surface fabrication techniques for ultra-precision fly cutting of large-aperture KDP crystals

    NASA Astrophysics Data System (ADS)

    Zhang, F. H.; Wang, S. F.; An, C. H.; Wang, J.; Xu, Q.

    2017-06-01

    Large-aperture potassium dihydrogen phosphate (KDP) crystals are widely used in the laser path of inertial confinement fusion (ICF) systems. The most common method of manufacturing half-meter KDP crystals is ultra-precision fly cutting. When processing KDP crystals by ultra-precision fly cutting, the dynamic characteristics of the fly cutting machine and fluctuations in the fly cutting environment are translated into surface errors at different spatial frequency bands. These machining errors should be suppressed effectively to guarantee that KDP crystals meet the full-band machining accuracy specified in the evaluation index. In this study, the anisotropic machinability of KDP crystals and the causes of typical surface errors in ultra-precision fly cutting of the material are investigated. The structures of the fly cutting machine and existing processing parameters are optimized to improve the machined surface quality. The findings are theoretically and practically important in the development of high-energy laser systems in China.

  8. Preparation and characterizations of activated carbon monolith from rubber wood and its effect on supercapacitor performances

    NASA Astrophysics Data System (ADS)

    Taer, E.; Taslim, R.; Deraman, M.

    2016-02-01

    Preparation of activated carbon monolith (ACM) from rubber wood was investigated. Two kind of preparation method were carried out by pre-carbonized of rubber wood saw dust and rubber wood material as it is naturally. The samples were prepared with pelletizing method and small cutting of rubber wood in cross sectional method. Both of samples were characterized by physical and electrochemical technique. The physical properties such as morphology and porosity were investigated. The electrochemical properties of both samples such as equivalent series resistances (ESR) and specific capacitances were also compared. In conclusion, this study showed that both of different preparation method would propose a simple method of ACM electrode preparation technique for supercapacitor applications.

  9. Sensitivity and specificity of the Beck Depression Inventory in cardiologic inpatients: how useful is the conventional cut-off score?

    PubMed

    Forkmann, Thomas; Vehren, Thomas; Boecker, Maren; Norra, Christine; Wirtz, Markus; Gauggel, Siegfried

    2009-10-01

    The Beck Depression Inventory (BDI) is widely used for depression screening in various patient populations. However, there are still insufficient data about its sensitivity and specificity in nonpsychiatric patients. Furthermore, some research suggests that somatic BDI items heighten its sum score artificially in physically ill patients. The aim of the present study was to validate the conventional BDI cut-off score by examination of its sensitivity and specificity in a mixed sample of cardiac inpatients and compare it to a modified "cognitive-emotional" BDI (BDI(c/e)) after exclusion of somatic items. A total of 126 cardiologic inpatients were assessed. Receiver operating characteristic curves (ROC) were calculated for total BDI (BDI(t)) and BDI(c/e). Screening performance of cut-off scores was evaluated using the Youden Index (Y). With the application of the conventional BDI cut-off score, ROC analysis revealed a moderate overall screening performance with Y=52.6 and an area under the curve (AUC) of 0.83. In contrast, Y improved to 57.5 at a cut-off score of >9, but screening performance was still not optimal. BDI(c/e) showed also a moderate screening performance (AUC=.82); Y was maximized at a cut-off score of >8 (Y=0.53.5). Again, no cut-off score provided optimal screening performance. The BDI cannot be recommended as a formal screening instrument in cardiac inpatients since no cut-off score for either BDI(t) or BDI(c/e) combined both sufficiently high sensitivity and specificity. However, the shorter BDI(c/e) could be used as alternative to BDI(t) which may be confounded in physically ill patients. Generally, researchers should consider using alternative screening instruments (e.g., the Hospital Anxiety and Depression Scale) instead.

  10. Diameter-limit cutting in Appalachian hardwoods: boon or bane?

    Treesearch

    G.R., Jr. Trimble; G.R. Trimble

    1971-01-01

    Diameter-limit cutting is widespread and is applied in a great many ways, often without appreciation of its advantages and disadvantages and withoutan understanding of its effects on subsequent stand development. Although the technique has advantages, unless applied carefully, it can have longlasting adverse effects on sawtimber production. The latest results of...

  11. Laser cutting eliminates nucleic acid cross-contamination in dried-blood-spot processing.

    PubMed

    Murphy, Sean C; Daza, Glenda; Chang, Ming; Coombs, Robert

    2012-12-01

    Dried blood spots (DBS) are useful for molecular assays but are prone to false positives from cross-contamination. In our malaria DBS assay, cross-contamination was encountered despite cleaning techniques suitable for HIV-1. We therefore developed a contact-free laser cutting system that effectively eliminated cross-contamination during DBS processing.

  12. Large-scale fabrication of micro-lens array by novel end-fly-cutting-servo diamond machining.

    PubMed

    Zhu, Zhiwei; To, Suet; Zhang, Shaojian

    2015-08-10

    Fast/slow tool servo (FTS/STS) diamond turning is a very promising technique for the generation of micro-lens array (MLA). However, it is still a challenge to process MLA in large scale due to certain inherent limitations of this technique. In the present study, a novel ultra-precision diamond cutting method, as the end-fly-cutting-servo (EFCS) system, is adopted and investigated for large-scale generation of MLA. After a detailed discussion of the characteristic advantages for processing MLA, the optimal toolpath generation strategy for the EFCS is developed with consideration of the geometry and installation pose of the diamond tool. A typical aspheric MLA over a large area is experimentally fabricated, and the resulting form accuracy, surface micro-topography and machining efficiency are critically investigated. The result indicates that the MLA with homogeneous quality over the whole area is obtained. Besides, high machining efficiency, extremely small volume of control points for the toolpath, and optimal usage of system dynamics of the machine tool during the whole cutting can be simultaneously achieved.

  13. Key improvements in machining of Ti6al4v alloy: A review

    NASA Astrophysics Data System (ADS)

    Katta, Sivakoteswararao; Chaitanya, G.

    2017-07-01

    Now a days the use of ti-6al-4v alloy is high in demand in many industries like aero space, bio medical automobile, space, military etc. the production rates in the industries are not sufficient because the machiniability of ti-6al-4v is the main problem, there are several cutting tools available for metal cutting operations still there is a gap in finding the proper cutting tool material for machining of ti-6al-4v. because the properties of titanium like high heat resistant, low thermal conductivity, low weight ratio, less corrosiveness, and more many properties attracting the industrialists to use titanium as their material for their products, many researchers done the research on machininbility of ti-6al-4v by using different tool materials. but as for my literature survey there is still lot of scope is available, to find better cutting tool with techniques for machining ti-6al-4v. in this paper iam discussing the work done by various researchers on ti-6al-4v alloy with different techniques.

  14. RESEARCH: Shrub Propagation Techniques for Biological Control ofInvading Tree Species

    PubMed

    Meilleur; Veronneau; Bouchard

    1997-05-01

    / The use of relatively stable shrub communities to control invasionby trees could be an efficient way of reducing herbicide applications, andthus represents an environmental gain, in areas such as rights-of-way. Thequestion is how to favor the expansion of these relatively stable shrubcommunities using different propagation techniques. Three experimentaltreatments, cutting back, layering, and cutting back-layering were performedon Cornus stolonifera, Salix petiolaris, and Spiraea albaclones already located within the corridor of an electrical power line. Toestablish the efficiency of treatments, we examined the statisticaldifferences of growth traits between species and treatments.An analysis of the effects of layering shows, after the first growth season,differences for all growth traits in only one species, Spiraea alba.After the second growth season, we observed the development of new aerialstems. Layering favors horizontal expansion of shrubs over heightdevelopment. The third year after treatment, the effect of layering isreduced except for Cornus stolonifera, which continuously increases,as shown by the significant progression of the clone issued from the layereven five years after treatments. With the cutting back technique, weexpected a distinct vertical growth of the shrubs at the expense ofincreasing the crown diameter. This technique would be best associated withthe rejuvenation of clones, followed by a layering of new shoots to allow ahorizontal expansion of the shrubs. Therefore, the formation of a dense shrubcommunity by layering should be considered a valuable approach for thebiological control of undesirable trees in powerline rights-of-way.KEY WORDS: Layering; Cutting back; Right-of-way; Cornus stolonifera;Salix petiolaris; Spiraea alba; Quebec

  15. Automated Cell-Cutting for Cell Cloning

    NASA Astrophysics Data System (ADS)

    Ichikawa, Akihiko; Tanikawa, Tamio; Matsukawa, Kazutsugu; Takahashi, Seiya; Ohba, Kohtaro

    We develop an automated cell-cutting technique for cell cloning. Animal cells softened by the cytochalasin treatment are injected into a microfluidic chip. The microfluidic chip contains two orthogonal channels: one microchannel is wide, used to transport cells, and generates the cutting flow; the other is thin and used for aspiration, fixing, and stretching of the cell. The injected cell is aspirated and stretched in the thin microchannel. Simultaneously, the volumes of the cell before and after aspiration are calculated; the volumes are used to calculate the fluid flow required to aspirate half the volume of the cell into the thin microchannel. Finally, we apply a high-speed flow in the orthogonal microchannel to bisect the cell. This paper reports the cutting process, the cutting system, and the results of the experiment.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Phelps, J.; Hoopingarner, J.

    Effective techniques have been developed from work on dozens of North Sea Wells to minimize the amount of oil-based mud discharged to the sea while maintaining acceptable levels of solids. Pressure to reduce pollution during the course of drilling prompted the development of these techniques. They involve personnel and optimization of mud system and procedures. Case histories demonstrate that regulations may be met with economical techniques using existing technology. The benefits of low solids content are widely known, and are a key part of any successful mud program. Good solids control should result in lower mud costs and better drillingmore » performance. Operators have specified high-performance shakers to accomplish this and have revised their mud programs with lower and lower allowable drilled solids percentages. This will pay off in certain areas. But with the U.K. Department of Energy regulations requiring cuttings oil discharge content (CODC) to be less than 150 g of oil/kg of dry solids discharge that went into effect Jan. 1, 1989, oil-loss control has a higher profile in the U.K. sector of the North Sea.« less

  17. X-Z-Theta cutting method

    DOEpatents

    Bieg, Lothar F.

    1993-01-12

    A method for machining a workpiece. The method includes the use of a rotary cutting tool mounted on the end of a movable arm. The arm is adapted to move in a plane perpendicular to the axis of rotation of the cutting tool. The cutting tool has cutting teeth to cut chips of material off of the workpiece in a predetermined size and shape to facilitate better removal of the chips from the workpiece. The teeth can be of different type and length to permit the tool to both rough cut and finish cut the workpiece during machining. The total depth of cut is divided by the number of tool teeth, so that the longest tool always performs the finishing cut.

  18. An “All-laser” Endothelial Transplant

    PubMed Central

    Rossi, Francesca; Canovetti, Annalisa; Malandrini, Alex; Lenzetti, Ivo; Pini, Roberto; Menabuoni, Luca

    2015-01-01

    The “all laser” assisted endothelial keratoplasty is a procedure that is performed with a femtosecond laser used to cut the donor tissue at an intended depth, and a near infrared diode laser to weld the corneal tissue. The proposed technique enables to reach the three main goals in endothelial keratoplasty: a precise control in the thickness of the donor tissue; its easy insertion in the recipient bed and a reduced risk of donor lenticule dislocation. The donor cornea thickness is measured in the surgery room with optical coherence tomography (OCT), in order to correctly design the donor tissue dimensions. A femtosecond laser is used to cut the donor cornea. The recipient eye is prepared by manual stripping of the descemetic membrane. The donor endothelium is inserted into a Busin-injector, the peripheral inner side is stained with a proper chromophore (a water solution of Indocyanine Green) and then it is pulled in the anterior chamber. The transplanted tissue is placed in the final and correct location and then diode laser welding is induced from outside the eyeball. The procedure has been performed on more than 15 patients evidencing an improvement in surgery performances, with a good recovery of visual acuity and a reduced donor lenticule dislocation event. PMID:26167711

  19. Piezosurgery for osteotomies in orbital surgery: Our experience and review of the literature

    PubMed Central

    Iacoangeli, Maurizio; Neri, Piergiorgio; Balercia, Paolo; Lupi, Ettore; Di Rienzo, Alessandro; Nocchi, Niccolò; Alvaro, Lorenzo; Scerrati, Massimo

    2012-01-01

    INTRODUCTION Piezoelectric bone surgery, simply known as Piezosurgery®, is a new promising technique for bone cutting based on ultrasonic microvibrations that allows to perform precise and thin osteotomies with soft tissue sparing. PRESENTATION OF CASE A 45-years-old woman presenting with progressive left ocular pain, diplopia on the lateral left gaze, and visible exophthalmos was admitted to our department. CT scan and MRI images documented a left supero-lateral orbital lesion. A left lateral orbitotomy using the piezoelectric scalpel was performed. The tumour (lacrimal gland lymphoma) was completely removed with no injuries to the orbital structures and with a perfect realignment of the bone stumps. DISCUSSION High powered pneumatic osteotome are commonly used to perform craniotomies. Large bone cutting groove and high temperatures developing at the contact site could produce an uneasy bone healing. The use of a piezoelectric scalpel allows to realize precise and thin osteotomies, facilitating craniotomy's borders ossification and avoiding injuries to non-osseous structures. CONCLUSION Widely used in Oral and Maxillofacial Surgery, Piezosurgery® can also be useful in neurosurgical approaches in order to obtain a faster bone flap re-ossification, a better aesthetic result, and a lower risks of dural layer and soft tissue damage. PMID:23276764

  20. Effects of cutting parameters and machining environments on surface roughness in hard turning using design of experiment

    NASA Astrophysics Data System (ADS)

    Mia, Mozammel; Bashir, Mahmood Al; Dhar, Nikhil Ranjan

    2016-07-01

    Hard turning is gradually replacing the time consuming conventional turning process, which is typically followed by grinding, by producing surface quality compatible to grinding. The hard turned surface roughness depends on the cutting parameters, machining environments and tool insert configurations. In this article the variation of the surface roughness of the produced surfaces with the changes in tool insert configuration, use of coolant and different cutting parameters (cutting speed, feed rate) has been investigated. This investigation was performed in machining AISI 1060 steel, hardened to 56 HRC by heat treatment, using coated carbide inserts under two different machining environments. The depth of cut, fluid pressure and material hardness were kept constant. The Design of Experiment (DOE) was performed to determine the number and combination sets of different cutting parameters. A full factorial analysis has been performed to examine the effect of main factors as well as interaction effect of factors on surface roughness. A statistical analysis of variance (ANOVA) was employed to determine the combined effect of cutting parameters, environment and tool configuration. The result of this analysis reveals that environment has the most significant impact on surface roughness followed by feed rate and tool configuration respectively.

  1. Development of a Laparoscopic Box Trainer Based on Open Source Hardware and Artificial Intelligence for Objective Assessment of Surgical Psychomotor Skills.

    PubMed

    Alonso-Silverio, Gustavo A; Pérez-Escamirosa, Fernando; Bruno-Sanchez, Raúl; Ortiz-Simon, José L; Muñoz-Guerrero, Roberto; Minor-Martinez, Arturo; Alarcón-Paredes, Antonio

    2018-05-01

    A trainer for online laparoscopic surgical skills assessment based on the performance of experts and nonexperts is presented. The system uses computer vision, augmented reality, and artificial intelligence algorithms, implemented into a Raspberry Pi board with Python programming language. Two training tasks were evaluated by the laparoscopic system: transferring and pattern cutting. Computer vision libraries were used to obtain the number of transferred points and simulated pattern cutting trace by means of tracking of the laparoscopic instrument. An artificial neural network (ANN) was trained to learn from experts and nonexperts' behavior for pattern cutting task, whereas the assessment of transferring task was performed using a preestablished threshold. Four expert surgeons in laparoscopic surgery, from hospital "Raymundo Abarca Alarcón," constituted the experienced class for the ANN. Sixteen trainees (10 medical students and 6 residents) without laparoscopic surgical skills and limited experience in minimal invasive techniques from School of Medicine at Universidad Autónoma de Guerrero constituted the nonexperienced class. Data from participants performing 5 daily repetitions for each task during 5 days were used to build the ANN. The participants tend to improve their learning curve and dexterity with this laparoscopic training system. The classifier shows mean accuracy and receiver operating characteristic curve of 90.98% and 0.93, respectively. Moreover, the ANN was able to evaluate the psychomotor skills of users into 2 classes: experienced or nonexperienced. We constructed and evaluated an affordable laparoscopic trainer system using computer vision, augmented reality, and an artificial intelligence algorithm. The proposed trainer has the potential to increase the self-confidence of trainees and to be applied to programs with limited resources.

  2. Technique for predicting ground-water discharge to surface coal mines and resulting changes in head

    USGS Publications Warehouse

    Weiss, L.S.; Galloway, D.L.; Ishii, Audrey L.

    1986-01-01

    Changes in seepage flux and head (groundwater level) from groundwater drainage into a surface coal mine can be predicted by a technique that considers drainage from the unsaturated zone. The user applies site-specific data to precalculated head and seepage-flux profiles. Groundwater flow through hypothetical aquifer cross sections was simulated using the U.S. Geological Survey finite-difference model, VS2D, which considers variably saturated two-dimensional flow. Conceptual models considered were (1) drainage to a first cut, and (2) drainage to multiple cuts, which includes drainage effects of an area surface mine. Dimensionless head and seepage flux profiles from 246 simulations are presented. Step-by-step instructions and examples are presented. Users are required to know aquifer characteristics and to estimate size and timing of the mine operation at a proposed site. Calculated groundwater drainage to the mine is from one excavated face only. First cut considers confined and unconfined aquifers of a wide range of permeabilities; multiple cuts considers unconfined aquifers of higher permeabilities only. The technique, developed for Illinois coal-mining regions that use area surface mining and evaluated with an actual field example, will be useful in assessing potential hydrologic impacts of mining. Application is limited to hydrogeologic settings and mine operations similar to those considered. Fracture flow, recharge, and leakage are nor considered. (USGS)

  3. Evaluation of laser cutting process with auxiliary gas pressure by soft computing approach

    NASA Astrophysics Data System (ADS)

    Lazov, Lyubomir; Nikolić, Vlastimir; Jovic, Srdjan; Milovančević, Miloš; Deneva, Heristina; Teirumenieka, Erika; Arsic, Nebojsa

    2018-06-01

    Evaluation of the optimal laser cutting parameters is very important for the high cut quality. This is highly nonlinear process with different parameters which is the main challenge in the optimization process. Data mining methodology is one of most versatile method which can be used laser cutting process optimization. Support vector regression (SVR) procedure is implemented since it is a versatile and robust technique for very nonlinear data regression. The goal in this study was to determine the optimal laser cutting parameters to ensure robust condition for minimization of average surface roughness. Three cutting parameters, the cutting speed, the laser power, and the assist gas pressure, were used in the investigation. As a laser type TruLaser 1030 technological system was used. Nitrogen as an assisted gas was used in the laser cutting process. As the data mining method, support vector regression procedure was used. Data mining prediction accuracy was very high according the coefficient (R2) of determination and root mean square error (RMSE): R2 = 0.9975 and RMSE = 0.0337. Therefore the data mining approach could be used effectively for determination of the optimal conditions of the laser cutting process.

  4. Analysis and Validation of Contactless Time-Gated Interrogation Technique for Quartz Resonator Sensors

    PubMed Central

    Baù, Marco; Ferrari, Marco; Ferrari, Vittorio

    2017-01-01

    A technique for contactless electromagnetic interrogation of AT-cut quartz piezoelectric resonator sensors is proposed based on a primary coil electromagnetically air-coupled to a secondary coil connected to the electrodes of the resonator. The interrogation technique periodically switches between interleaved excitation and detection phases. During the excitation phase, the resonator is set into vibration by a driving voltage applied to the primary coil, whereas in the detection phase, the excitation signal is turned off and the transient decaying response of the resonator is sensed without contact by measuring the voltage induced back across the primary coil. This approach ensures that the readout frequency of the sensor signal is to a first order approximation independent of the interrogation distance between the primary and secondary coils. A detailed theoretical analysis of the interrogation principle based on a lumped-element equivalent circuit is presented. The analysis has been experimentally validated on a 4.432 MHz AT-cut quartz crystal resonator, demonstrating the accurate readout of the series resonant frequency and quality factor over an interrogation distance of up to 2 cm. As an application, the technique has been applied to the measurement of liquid microdroplets deposited on a 4.8 MHz AT-cut quartz crystal. More generally, the proposed technique can be exploited for the measurement of any physical or chemical quantities affecting the resonant response of quartz resonator sensors. PMID:28574459

  5. Analysis and Validation of Contactless Time-Gated Interrogation Technique for Quartz Resonator Sensors.

    PubMed

    Baù, Marco; Ferrari, Marco; Ferrari, Vittorio

    2017-06-02

    A technique for contactless electromagnetic interrogation of AT-cut quartz piezoelectric resonator sensors is proposed based on a primary coil electromagnetically air-coupled to a secondary coil connected to the electrodes of the resonator. The interrogation technique periodically switches between interleaved excitation and detection phases. During the excitation phase, the resonator is set into vibration by a driving voltage applied to the primary coil, whereas in the detection phase, the excitation signal is turned off and the transient decaying response of the resonator is sensed without contact by measuring the voltage induced back across the primary coil. This approach ensures that the readout frequency of the sensor signal is to a first order approximation independent of the interrogation distance between the primary and secondary coils. A detailed theoretical analysis of the interrogation principle based on a lumped-element equivalent circuit is presented. The analysis has been experimentally validated on a 4.432 MHz AT-cut quartz crystal resonator, demonstrating the accurate readout of the series resonant frequency and quality factor over an interrogation distance of up to 2 cm. As an application, the technique has been applied to the measurement of liquid microdroplets deposited on a 4.8 MHz AT-cut quartz crystal. More generally, the proposed technique can be exploited for the measurement of any physical or chemical quantities affecting the resonant response of quartz resonator sensors.

  6. In vitro comparison of the cutting efficiency and temperature production of ten different rotary cutting instruments. Part II: electric handpiece and comparison with turbine.

    PubMed

    Ercoli, Carlo; Rotella, Mario; Funkenbusch, Paul D; Russell, Scott; Feng, Changyong

    2009-05-01

    The cutting behavior of dental rotary cutting instruments is influenced by the handpiece used. While the turbine handpiece has been extensively tested in previous studies, limited published information exists on the use of rotary cutting instruments with the electric handpiece system and on possible interactions between rotary cutting instruments and handpiece type. The purpose of this study was to examine the cutting performance of a wide selection of rotary cutting instruments tested with the electric handpiece and compare the results with those of the air-turbine handpiece (Part I), identifying possible interactions between handpiece type and rotary cutting instruments. Ten groups of rotary cutting instruments (n=30) designed for tooth preparation were selected: 9 diamond (7 multi-use, 2 disposable) and 1 carbide. Macor blocks (n=75) were used as a substrate, and 4 cuts were made on each specimen, using a new rotary cutting instrument each time, for a total of 300 cuts. The cuts were performed with an electric handpiece (Intramatic Lux K200), with the same methods used in the Part I study. To qualitatively evaluate the rotary cutting instrument surface characteristics, 1 specimen from each group was examined 3 times with a scanning electron microscope (SEM): before use, then after use, but before being cleaned and sterilized, and finally, after ultrasonic cleaning. To compare rotary cutting instrument performance between the turbine and electric handpieces, the data were analyzed using 2-way ANOVA to study the main effects of the group of rotary cutting instruments, handpieces, and their interaction. For analysis of the significant main effect, 1-way ANOVA and Tukey's Studentized Range test were used (alpha=.05). Compared to the baseline temperature, all rotary cutting instruments showed a reduction of the temperature in the simulated pulp chamber when tested with the electric handpiece. The Great White Ultra (carbide bur) showed the highest rate of advancement (0.17 mm/s) and lowest applied load (108.35 g). Considering all rotary cutting instruments as a single group, the electric handpiece showed mean lower temperature (26.68 degrees C), higher rate of advancement (0.12 mm/s), and higher load (124.53 g) than the air-turbine handpiece (28.37 degrees C, 0.11 mm/s, and 121.7 g, respectively). Considering each single group of rotary cutting instruments, significant differences were found for the electric or air-turbine handpiece. The tested carbide bur showed greater cutting efficiency than the tested diamond rotary cutting instruments when used with the electric handpiece. The electric handpiece showed a higher cutting efficiency than the turbine, especially when used with the carbide bur, probably due to its greater torque.

  7. Loblolly pine cutting morphological traits: effects on rooting and field performance

    Treesearch

    G. Sam Foster; H.E. Stelzer; J.B. McRae

    2000-01-01

    Shoot cuttings were harvested from 4-year-old loblolly pine hedges in March and September of 1987, and placed into a series of factorial combinations of cutting length, diameter class, and the presence/absence of a terminal bud to assess effects on rooting and field performance. Average rooting in the March trial was 50 percent and only 20 percent for the September...

  8. ED becomes 'lean' and cuts LBTC, LOS times.

    PubMed

    2008-04-01

    Lean manufacturing techniques, first developed by Toyota, can be successfully adapted to help improve processes in your ED. St. Luke's Episcopal Hospital in Houston, has used Lean to reduce median length of stay, frequency of diversions, and the percentage of patients who left before treatment was complete (LBTC). Here's why "Lean" can help improve the performance of your ED: It enables you and your staff to see things from the patient's point of view. Lean tools enable you to view the status of your department in real-time and to compare that status with your performance goals. Exercises help identify areas where your processes break down and determine the most likely solutions.

  9. Investigation of an Anomaly Observed in Impedance Eduction Techniques

    NASA Technical Reports Server (NTRS)

    Watson, W. R.; Jones, M. G.; Parrott, T. L.

    2008-01-01

    An intensive investigation into the cause of anomalous behavior commonly observed in impedance eduction techniques is performed. The investigation consists of grid refinement studies, detailed evaluation of results at and near anti-resonance frequencies, comparisons of different model results with synthesized and measured data, assessment or optimization techniques, and evaluation or boundary condition effects. Results show that the root cause of the anomalous behavior is the sensitivity of the educed impedance to small errors in the measured termination resistance at frequencies near anti-resonance or cut-on of a higher-order mode. Evidence is presented to show that the common usage of an anechoic, plane wave termination boundary condition in ducts where the "true" termination is reflective may act as a trigger for these anomalies. Replacing the exit impedance boundary condition by an exit pressure condition is shown to reduce the anomalous results.

  10. Computer-aided design and computer-aided manufacturing cutting guides and customized titanium plates are useful in upper maxilla waferless repositioning.

    PubMed

    Mazzoni, Simona; Bianchi, Alberto; Schiariti, Giulio; Badiali, Giovanni; Marchetti, Claudio

    2015-04-01

    The purpose of the present study was to develop a computer-aided design (CAD) and computer-aided manufacturing (CAM) technique that enabled fabrication of surgical cutting guides and titanium fixation plates that would allow the upper maxilla to be repositioned correctly without a surgical splint in orthognathic patients. Ten patients were recruited. A complete CAD-CAM workflow for orthognathic surgery has 3 steps: 1) virtual planning of the surgical treatment, 2) CAD-CAM and 3-dimensional printing of customized surgical devices (surgical cutting guide and titanium fixation plates), and 3) computer-aided surgery. Upper maxilla repositioning was performed in a waferless manner using a CAD-CAM device: the surgical cutting guide was used during surgery to pilot the osteotomy line that had been planned preoperatively at the computer and the custom-made fixation titanium plates allowed desired repositioning of the maxilla. To evaluate the reproducibility of this CAD-CAM orthognathic surgical method, the virtually planned and actually achieved positions of the upper maxilla were compared. Overlap errors using a threshold value smaller than 2 mm were evaluated, and the frequency of such errors was used as a measurement of accuracy. By this definition, the accuracy was 100% in 7 patients (range in all patients, 62 to 100%; median, 92.7%). These results tend to confirm that the use of CAD-CAM cutting guides and customized titanium plates for upper maxilla repositioning represents a promising method for the accurate reproduction of preoperative virtual planning without the use of surgical splints. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Optimization and Analysis of Laser Beam Machining Parameters for Al7075-TiB2 In-situ Composite

    NASA Astrophysics Data System (ADS)

    Manjoth, S.; Keshavamurthy, R.; Pradeep Kumar, G. S.

    2016-09-01

    The paper focuses on laser beam machining (LBM) of In-situ synthesized Al7075-TiB2 metal matrix composite. Optimization and influence of laser machining process parameters on surface roughness, volumetric material removal rate (VMRR) and dimensional accuracy of composites were studied. Al7075-TiB2 metal matrix composite was synthesized by in-situ reaction technique using stir casting process. Taguchi's L9 orthogonal array was used to design experimental trials. Standoff distance (SOD) (0.3 - 0.5mm), Cutting Speed (1000 - 1200 m/hr) and Gas pressure (0.5 - 0.7 bar) were considered as variable input parameters at three different levels, while power and nozzle diameter were maintained constant with air as assisting gas. Optimized process parameters for surface roughness, volumetric material removal rate (VMRR) and dimensional accuracy were calculated by generating the main effects plot for signal noise ratio (S/N ratio) for surface roughness, VMRR and dimensional error using Minitab software (version 16). The Significant of standoff distance (SOD), cutting speed and gas pressure on surface roughness, volumetric material removal rate (VMRR) and dimensional error were calculated using analysis of variance (ANOVA) method. Results indicate that, for surface roughness, cutting speed (56.38%) is most significant parameter followed by standoff distance (41.03%) and gas pressure (2.6%). For volumetric material removal (VMRR), gas pressure (42.32%) is most significant parameter followed by cutting speed (33.60%) and standoff distance (24.06%). For dimensional error, Standoff distance (53.34%) is most significant parameter followed by cutting speed (34.12%) and gas pressure (12.53%). Further, verification experiments were carried out to confirm performance of optimized process parameters.

  12. Ventilation via Cut Nasotracheal Tube During General Anesthesia

    PubMed Central

    Asahi, Yoshinao; Omichi, Shiro; Adachi, Seita; Kagamiuchi, Hajime; Kotani, Junichiro

    2013-01-01

    Many patients with disabilities need recurrent dental treatment under general anesthesia because of high caries prevalence and the nature of dental treatment. We evaluated the use of a nasal device as a possible substitute for flexible laryngeal mask airway to reduce the risk of unexpected failure accompanying intubation; we succeeded in ventilating the lungs with a cut nasotracheal tube (CNT) with its tip placed in the pharynx. We hypothesized that this technique would be useful during dental treatment under general anesthesia and investigated its usefulness as part of a minimally invasive technique. A prospective study was designed using general anesthesia in 37 dental patients with disabilities such as intellectual impairment, autism, and cerebral palsy. CNT ventilation was compared with mask ventilation with the patient in 3 positions: the neck in flexion, horizontal position, and in extension. The effect of mouth gags was also recorded during CNT ventilation. The percentages of cases with effective ventilation were similar for the 2 techniques in the neck extension and horizontal positions (89.2–97.3%). However, CNT ventilation was significantly more effective than mask ventilation in the neck flexion position (94.6 vs 45.9%; P < .0001). Mouth gags slightly reduced the rate of effective ventilation in the neck flexion position. Most dental treatments involving minor oral surgeries were performed using mouth gags during CNT ventilation. CNT ventilation was shown to be superior to mask ventilation and is useful during dental treatment under general anesthesia. PMID:23506278

  13. Piezosurgery in Modified Pterional Orbital Decompression Surgery in Graves Disease.

    PubMed

    Grauvogel, Juergen; Scheiwe, Christian; Masalha, Waseem; Jarc, Nadja; Grauvogel, Tanja; Beringer, Andreas

    2017-10-01

    Piezosurgery uses microvibrations to selectively cut bone, preserving the adjacent soft tissue. The present study evaluated the use of piezosurgery for bone removal in orbital decompression surgery in Graves disease via a modified pterional approach. A piezosurgical device (Piezosurgery medical) was used in 14 patients (20 orbits) with Graves disease who underwent orbital decompression surgery in additional to drills and rongeurs for bone removal of the lateral orbital wall and orbital roof. The practicability, benefits, and drawbacks of this technique in orbital decompression surgery were recorded. Piezosurgery was evaluated with respect to safety, preciseness of bone cutting, and preservation of the adjacent dura and periorbita. Preoperative and postoperative clinical outcome data were assessed. The orbital decompression surgery was successful in all 20 orbits, with good clinical outcomes and no postoperative complications. Piezosurgery proved to be a safe tool, allowing selective bone cutting with no damage to the surrounding soft tissue structures. However, there were disadvantages concerning the intraoperative handling in the narrow space and the efficiency of bone removal was limited in the orbital decompression surgery compared with drills. Piezosurgery proved to be a useful tool in bone removal for orbital decompression in Graves disease. It is safe and easy to perform, without any danger of damage to adjacent tissue because of its selective bone-cutting properties. Nonetheless, further development of the device is necessary to overcome the disadvantages in intraoperative handling and the reduced bone removal rate. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. A Cartesian cut cell method for rarefied flow simulations around moving obstacles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dechristé, G., E-mail: Guillaume.Dechriste@math.u-bordeaux1.fr; CNRS, IMB, UMR 5251, F-33400 Talence; Mieussens, L., E-mail: Luc.Mieussens@math.u-bordeaux1.fr

    2016-06-01

    For accurate simulations of rarefied gas flows around moving obstacles, we propose a cut cell method on Cartesian grids: it allows exact conservation and accurate treatment of boundary conditions. Our approach is designed to treat Cartesian cells and various kinds of cut cells by the same algorithm, with no need to identify the specific shape of each cut cell. This makes the implementation quite simple, and allows a direct extension to 3D problems. Such simulations are also made possible by using an adaptive mesh refinement technique and a hybrid parallel implementation. This is illustrated by several test cases, including amore » 3D unsteady simulation of the Crookes radiometer.« less

  15. Imaging, cutting, and collecting instrument and method

    DOEpatents

    Tench, R.J.; Siekhaus, W.J.; Balooch, M.; Balhorn, R.L.; Allen, M.J.

    1995-10-31

    Instrumentation and techniques are described to image small objects, such as but not limited to individual human chromosomes, with nanometer resolution. This instrument and method are also used to cut-off identified parts of objects, to move around and manipulate the cut-off parts on the substrate on which they are being imaged to predetermined locations on the substrate, and to remove the cut-off parts from the substrate. This is accomplished using an atomic force microscope (AFM) and by modification of the conventional cantilever stylus assembly of an AFM. The plural cantilevers are used with either sharp-tips or knife-edges. In addition, the invention can be utilized for measuring the hardness of materials. 10 figs.

  16. Volume reduction of hot cell plastic wastes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dykes, F W; Henscheid, J P; Lewis, L C

    1989-09-19

    The disposal of radioactively-contaminated solid wastes has become a national crisis. In such circumstances, it is imperative that this waste be reduced to minimum volume and be packaged to prevent pollution of the environment. The majority of the solid waste generated at the hot cell under consideration is plastic lab ware. Cutting this waste into small pieces with a hot wire technique reduced the volume 66%. Melting the waste, although more time consuming, reduced the volume 90%. The hot wire technique can also be used to cut up damaged master slave manipulator boots, greatly reducing their disposal volume.

  17. Use of Piezosurgery for removal of retrovertebral body osteophytes in anterior cervical discectomy.

    PubMed

    Grauvogel, Juergen; Scheiwe, Christian; Kaminsky, Jan

    2014-04-01

    The relatively new technique of Piezosurgery is based on microvibrations, generated by the piezoelectrical effect, which results in selective bone cutting with preservation of adjacent soft tissue. To study the applicability of Piezosurgery in anterior cervical discectomy with fusion (ACDF) surgery. Prospective clinical study at the neurosurgical department of the University of Freiburg, Germany. Nine patients with cervical disc herniation and retrovertebral osteophytes who underwent ACDF surgery. Piezosurgery was evaluated with respect to practicability, safety, preciseness of bone cutting, and preservation of adjacent neurovascular tissue. Pre- and postoperative clinical and radiological data were assessed. Piezosurgery was supportively used in ACDF in nine patients with either radiculopathy or myelopathy from disc herniation or ventral osteophytes. After discectomy, osteophytes were removed with Piezosurgery to decompress the spinal canal and the foramina. Angled inserts were used, allowing for cutting even retrovertebral osteophytes. In all nine cases, Piezosurgery cut bone selectively with no damage to nerve roots, dura, or posterior longitudinal ligament. None of the patients experienced any new neurological deficit after the operation. The handling of the instrument was safe and the cut precise. Osteophytic spurs, even retrovertebral ones that generally only can be approached via corpectomies, could be safely removed because of the angled inserts through the disc space. Currently, a slightly prolonged operation time was observed for Piezosurgery. Furthermore, the design of the handpiece could be further improved to facilitate the intraoperative handling in ACDF. Piezosurgery proved to be a useful and safe technique for selective bone cutting and removal of osteophytes with preservation of neuronal and soft tissue in ACDF. In particular, the angled inserts were effective in cutting bone spurs behind the adjacent vertebra which cannot be reached with conventional rotating burs. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. A comparative study on performance of CBN inserts when turning steel under dry and wet conditions

    NASA Astrophysics Data System (ADS)

    Abdullah Bagaber, Salem; Razlan Yusoff, Ahmad

    2017-10-01

    Cutting fluids is the most unsustainable components of machining processes, it is negatively impacting on the environmental and additional energy required. Due to its high strength and corrosion resistance, the machinability of stainless steel has attracted considerable interest. This study aims to evaluate performance of cubic boron nitride (CBN) inserts for the machining parameters includes the power consumption and surface roughness. Due to the high single cutting-edge cost of CBN, the performance of significant is importance for hard finish turning. The present work also deals with a comparative study on power consumption and surface roughness under dry and flood conditions. Turning process of the stainless steel 316 was performed. A response surface methodology based box-behnken design (BBD) was utilized for statistical analysis. The optimum process parameters are determined as the overall performance index. The comparison study has been done between dry and wet stainless-steel cut in terms of minimum value of energy and surface roughness. The result shows the stainless still can be machined under dry condition with 18.57% improvement of power consumption and acceptable quality compare to the wet cutting. The CBN tools under dry cutting stainless steel can be used to reduce the environment impacts in terms of no cutting fluid use and less energy required which is effected in machining productivity and profit.

  19. Effect of magneto rheological damper on tool vibration during hard turning

    NASA Astrophysics Data System (ADS)

    Paul, P. Sam; Varadarajan, A. S.

    2012-12-01

    Recently, the concept of hard turning has gained considerable attention in metal cutting as it can apparently replace the traditional process cycle of turning, heat treating, and finish grinding for assembly of hard wear resistant steel parts. The present investigation aims at developing a magneto rheological (MR) fluid damper for suppressing tool vibration and promoting better cutting performance during hard turning. The magneto rheological Fluid acts as a viscoelastic spring with non-linear vibration characteristics that are controlled by the composition of the magneto rheological fluid, the shape of the plunger and the electric parameters of the magnetizing field. Cutting experiments were conducted to arrive at a set of electrical, compositional and shape parameters that can suppress tool vibration and promote better cutting performance during turning of AISI 4340 steel of 46 HRC with minimal fluid application using hard metal insert with sculptured rake face. It was observed that the use of MR fluid damper reduces tool vibration and improves the cutting performance effectively. Also commercialization of this idea holds promise to the metal cutting industry.

  20. Investigations on high speed machining of EN-353 steel alloy under different machining environments

    NASA Astrophysics Data System (ADS)

    Venkata Vishnu, A.; Jamaleswara Kumar, P.

    2018-03-01

    The addition of Nano Particles into conventional cutting fluids enhances its cooling capabilities; in the present paper an attempt is made by adding nano sized particles into conventional cutting fluids. Taguchi Robust Design Methodology is employed in order to study the performance characteristics of different turning parameters i.e. cutting speed, feed rate, depth of cut and type of tool under different machining environments i.e. dry machining, machining with lubricant - SAE 40 and machining with mixture of nano sized particles of Boric acid and base fluid SAE 40. A series of turning operations were performed using L27 (3)13 orthogonal array, considering high cutting speeds and the other machining parameters to measure hardness. The results are compared among the different machining environments, and it is concluded that there is considerable improvement in the machining performance using lubricant SAE 40 and mixture of SAE 40 + boric acid compared with dry machining. The ANOVA suggests that the selected parameters and the interactions are significant and cutting speed has most significant effect on hardness.

  1. Improved transformer-winding method

    NASA Technical Reports Server (NTRS)

    Mclyman, W. T.

    1978-01-01

    Proposed technique using special bobbin and fixture to wind copper wire directly on core eliminates need core cut prior to assembly. Application of technique could result in production of quieter core with increased permeability and no localized heating.

  2. Cut set-based risk and reliability analysis for arbitrarily interconnected networks

    DOEpatents

    Wyss, Gregory D.

    2000-01-01

    Method for computing all-terminal reliability for arbitrarily interconnected networks such as the United States public switched telephone network. The method includes an efficient search algorithm to generate minimal cut sets for nonhierarchical networks directly from the network connectivity diagram. Efficiency of the search algorithm stems in part from its basis on only link failures. The method also includes a novel quantification scheme that likewise reduces computational effort associated with assessing network reliability based on traditional risk importance measures. Vast reductions in computational effort are realized since combinatorial expansion and subsequent Boolean reduction steps are eliminated through analysis of network segmentations using a technique of assuming node failures to occur on only one side of a break in the network, and repeating the technique for all minimal cut sets generated with the search algorithm. The method functions equally well for planar and non-planar networks.

  3. 75 FR 52037 - Welding, Cutting and Brazing Standard; Extension of the Office of Management and Budget's (OMB...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-24

    ...] Welding, Cutting and Brazing Standard; Extension of the Office of Management and Budget's (OMB) Approval... requirements contained in the Welding, Cutting and Brazing Standard (29 CFR part 1910, subpart Q). The information collected is used by employers and workers whenever welding, cutting and brazing are performed...

  4. The Effects of Cryogenic Treatment on Cutting Tools

    NASA Astrophysics Data System (ADS)

    Kumar, Satish; Khedkar, Nitin K.; Jagtap, Bhushan; Singh, T. P.

    2017-08-01

    Enhancing the cutting tool life is important and economic factor to reduce the tooling as well as manufacturing cost. The tool life is improved considerably by 92 % after cryogenic treatment. The cryogenic treatment is a one-time permanent, sub-zero heat treatment that entirely changes cross-section of cutting tool. The cryogenic treatment is carried out with deep freezing of cutting tool materials to enhance physical and mechanical properties. The cryogenic treatment improves mechanical such as hardness, toughness and tribological properties such as wear resistance, coefficient of friction, surface finish, dimensional stability and stress relief. The deep cryogenic treatment is the most beneficial treatment applied on cutting tools. The cryogenic treatment is the most advanced heat treatment and popular to improve performance of the cutting tool. The optimization of cryogenic treatment variables is necessary to improve tool life. This study reviews the effects of cryogenic treatment on microstructure, tribological properties of tool steels and machining applications of cutting tool by investigating the surface and performing the surface characterization test like SEM. The economy of cutting tool can be achieved by deep cryogenic treatment.

  5. Comparison of silvicultural and natural disturbance effects on terrestrial salamanders in northern hardwood forests

    Treesearch

    Daniel J. Hocking; Kimberly J. Babbitt; Mariko Yamasaki

    2013-01-01

    In forested ecosystems timber harvesting has the potential to emulate natural disturbances, thereby maintaining the natural communities adapted to particular disturbances. We compared the effects of even-aged (clearcut and patch cut) and uneven-aged (group cut, single-tree selection) timber management techniques with natural ice-storm damage and unmanipulated reference...

  6. Laser Cutting Eliminates Nucleic Acid Cross-Contamination in Dried-Blood-Spot Processing

    PubMed Central

    Daza, Glenda; Chang, Ming; Coombs, Robert

    2012-01-01

    Dried blood spots (DBS) are useful for molecular assays but are prone to false positives from cross-contamination. In our malaria DBS assay, cross-contamination was encountered despite cleaning techniques suitable for HIV-1. We therefore developed a contact-free laser cutting system that effectively eliminated cross-contamination during DBS processing. PMID:23052309

  7. Intraoperative Comparison of Measured Resection and Gap Balancing Using a Force Sensor: A Prospective, Randomized Controlled Trial.

    PubMed

    Cidambi, Krishna R; Robertson, Nicholas; Borges, Camille; Nassif, Nader A; Barnett, Steven L

    2018-07-01

    For establishing femoral component position, gap-balancing (GB) and measured resection (MR) techniques were compared using a force sensor. Ninety-one patients were randomized to undergo primary total knee arthroplasty using either MR (n = 43) or GB (n = 48) technique using a single total knee arthroplasty design. GB was performed with an instrumented tensioner. Force sensor data were obtained before the final implantation. GB resulted in greater range of femoral component rotation vs MR (1.5° ± 2.9° vs 3.1° ± 0.5°, P < .05) and posterior condylar cut thickness medially (10.2 ± 2.0 mm vs 9.0 ± 1.3 mm) and laterally (8.5 ± 1.9 mm vs 6.4 ± 1.0 mm). Force sensor data showed a decreased intercompartmental force difference at full flexion in GB (.8 ± 2.3 vs 2.0 ± 3.3u, 1u ≈ 15 N, P < .05). GB resulted in a greater range of femoral component rotation and thicker posterior condylar cuts resulting in an increased flexion space relative to MR. Intercompartmental force difference trended toward a more uniform distribution between full extension and full flexion in the GB vs MR group. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Water-tight knee arthrotomy closure: comparison of a novel single bidirectional barbed self-retaining running suture versus conventional interrupted sutures.

    PubMed

    Nett, Michael; Avelar, Rui; Sheehan, Michael; Cushner, Fred

    2011-03-01

    Standard medial parapatellar arthrotomies of 10 cadaveric knees were closed with either conventional interrupted absorbable sutures (control group, mean of 19.4 sutures) or a single running knotless bidirectional barbed absorbable suture (experimental group). Water-tightness of the arthrotomy closure was compared by simulating a tense hemarthrosis and measuring arthrotomy leakage over 3 minutes. Mean total leakage was 356 mL and 89 mL in the control and experimental groups, respectively (p = 0.027). Using 8 of the 10 knees (4 closed with control sutures, 4 closed with an experimental suture), a tense hemarthrosis was again created, and iatrogenic suture rupture was performed: a proximal suture was cut at 1 minute; a distal suture was cut at 2 minutes. The impact of suture rupture was compared by measuring total arthrotomy leakage over 3 minutes. Mean total leakage was 601 mL and 174 mL in the control and experimental groups, respectively (p = 0.3). In summary, using a cadaveric model, arthrotomies closed with a single bidirectional barbed running suture were statistically significantly more water-tight than those closed using a standard interrupted technique. The sample size was insufficient to determine whether the two closure techniques differed in leakage volume after suture rupture.

  9. A modified method using a two-port approach for accessing the hilar vasculature without transferring an endostapler from camera port to utility port during thoracoscopic right upper lobectomy.

    PubMed

    Jiao, W; Zhao, Y; Xuan, Y; Wang, M

    2015-02-01

    For thoracoscopic upper lobectomies, most cutting endostaplers must be inserted through the camera port when using a two-port approach. Access to the hilar vasculature through only the utility port remains a challenge. In this study, we describe a procedure to access the hilar vasculature without transferring the endostapler site during a thoracoscopic right upper lobectomy. A 2.5-cm utility anterior incision was made in the fourth intercostal space. The posterior mediastinal visceral pleura were dissected to expose the posterior portion of the right upper bronchus and the anterior trunk of the right pulmonary artery. The pleura over the right hilar vasculature were then peeled with an electrocoagulation hook. The anterior trunk of the right pulmonary artery was then transected with a cutting endostapler through the utility port firstly. This crucial maneuver allowed the endostapler access to the right upper lobe pulmonary vein. The hilar structures were then easily handled in turn. This novel technique was performed successfully in 32 patients, with no perioperative deaths. The average operation time was 120.6 min (range 75-180 min). This novel technique permits effective control of the hilar vessels through the utility port, enabling simple, safe, quick and effective resection.

  10. Method for Fabricating Composite Structures Including Continuous Press Forming and Pultrusion Processing

    NASA Technical Reports Server (NTRS)

    Farley, Gary L. (Inventor)

    1995-01-01

    A method for fabricating composite structures at a low-cost, moderate-to-high production rate is disclosed. A first embodiment of the method includes employing a continuous press forming fabrication process. A second embodiment of the method includes employing a pultrusion process for obtaining composite structures. The methods include coating yarns with matrix material, weaving the yarn into fabric to produce a continuous fabric supply, and feeding multiple layers of net-shaped fabrics having optimally oriented fibers into a debulking tool to form an undebulked preform. The continuous press forming fabrication process includes partially debulking the preform, cutting the partially debulked preform, and debulking the partially debulked preform to form a netshape. An electron-beam or similar technique then cures the structure. The pultrusion fabric process includes feeding the undebulked preform into a heated die and gradually debulking the undebulked preform. The undebulked preform in the heated die changes dimension until a desired cross-sectional dimension is achieved. This process further includes obtaining a net-shaped infiltrated uncured preform, cutting the uncured preform to a desired length, and electron-beam curing (or similar technique) the uncured preform. These fabrication methods produce superior structures formed at higher production rates, resulting in lower cost and high structural performance.

  11. Cavity formation and surface modeling of laser milling process under a thin-flowing water layer

    NASA Astrophysics Data System (ADS)

    Tangwarodomnukun, Viboon

    2016-11-01

    Laser milling process normally involves a number of laser scans over a workpiece to selectively remove the material and then to form cavities with shape and dimensions required. However, this process adversely causes a heat accumulation in work material, which can in turn damage the laser-milled area and vicinity in terms of recast deposition and change of material properties. Laser milling process performing in a thin-flowing water layer is a promising method that can overcome such damage. With the use of this technique, water can flush away the cut debris and at the same time cool the workpiece during the ablation. To understand the potential of this technique for milling application, the effects of process parameters on cavity dimensions and surface roughness were experimentally examined in this study. Titanium sheet was used as a workpiece to be milled by a nanosecond pulse laser under different water flow velocities. A smooth and uniform cut feature can be obtained when the metal was ablated under the high laser pulse frequency and high water flow velocity. Furthermore, a surface model based on the energy balance was developed in this study to predict the cavity profile and surface roughness. By comparing to the experiments, the predicted profiles had a good agreement with the measured ones.

  12. Comparing cutting efficiencies of diamond burs using a high-speed electric handpiece.

    PubMed

    Chung, Evelyn M; Sung, Eric C; Wu, Ben; Caputo, Angelo A

    2006-01-01

    This study sought to compare the cutting efficiency of different diamond burs on initial use as well as during repeated use, alternating with sterilization. Long, round-end, tapered diamond burs with similar diameter, profile, and diamond coarseness (125-150 microm grit) were used. A high-torque, high-speed electric handpiece (set at 200,000 rpm) was utilized with a coolant flow rate of 25 mL/min. Burs were tested under a constant load of 170 g while cuts were made on a machinable ceramic substrate block. Each bur was subjected to five consecutive cuts for 30 seconds of continuous operation and the cutting depths were measured. All burs performed similarly on the first cut. Cutting efficiencies for three of the bur groups decreased significantly after the first cycle; however, by the fifth cycle, all bur groups performed similarly without any significant differences (p > 0.05). A scanning electron microscope revealed significant crystal loss after each use.

  13. Damage Detection in Concrete Elements with Surface Wave Measurements

    DTIC Science & Technology

    1992-01-01

    Structures, identified the need for "Better techniques for detection of flaws or defects inside structural members". At the same conference, the...1 6 12 1 7 13 19 13 7 18 12 6 17 11 5 14 8 2 10 8 2 83 Saw cut Sawm cu Saw cut Sawcu SSaw cut Figre4. -I ltie ocaio o Dmae ndSoc- RcieAra 84 4.2...cracking and defects . Some methods used in the past to determine the size and location of cracks are the P-wave arrival time, imaging systems, time

  14. Detection of fallen trees in ALS point clouds using a Normalized Cut approach trained by simulation

    NASA Astrophysics Data System (ADS)

    Polewski, Przemyslaw; Yao, Wei; Heurich, Marco; Krzystek, Peter; Stilla, Uwe

    2015-07-01

    Downed dead wood is regarded as an important part of forest ecosystems from an ecological perspective, which drives the need for investigating its spatial distribution. Based on several studies, Airborne Laser Scanning (ALS) has proven to be a valuable remote sensing technique for obtaining such information. This paper describes a unified approach to the detection of fallen trees from ALS point clouds based on merging short segments into whole stems using the Normalized Cut algorithm. We introduce a new method of defining the segment similarity function for the clustering procedure, where the attribute weights are learned from labeled data. Based on a relationship between Normalized Cut's similarity function and a class of regression models, we show how to learn the similarity function by training a classifier. Furthermore, we propose using an appearance-based stopping criterion for the graph cut algorithm as an alternative to the standard Normalized Cut threshold approach. We set up a virtual fallen tree generation scheme to simulate complex forest scenarios with multiple overlapping fallen stems. This simulated data is then used as a basis to learn both the similarity function and the stopping criterion for Normalized Cut. We evaluate our approach on 5 plots from the strictly protected mixed mountain forest within the Bavarian Forest National Park using reference data obtained via a manual field inventory. The experimental results show that our method is able to detect up to 90% of fallen stems in plots having 30-40% overstory cover with a correctness exceeding 80%, even in quite complex forest scenes. Moreover, the performance for feature weights trained on simulated data is competitive with the case when the weights are calculated using a grid search on the test data, which indicates that the learned similarity function and stopping criterion can generalize well on new plots.

  15. Estimation of the influence of tool wear on force signals: A finite element approach in AISI 1045 orthogonal cutting

    NASA Astrophysics Data System (ADS)

    Equeter, Lucas; Ducobu, François; Rivière-Lorphèvre, Edouard; Abouridouane, Mustapha; Klocke, Fritz; Dehombreux, Pierre

    2018-05-01

    Industrial concerns arise regarding the significant cost of cutting tools in machining process. In particular, their improper replacement policy can lead either to scraps, or to early tool replacements, which would waste fine tools. ISO 3685 provides the flank wear end-of-life criterion. Flank wear is also the nominal type of wear for longest tool lifetimes in optimal cutting conditions. Its consequences include bad surface roughness and dimensional discrepancies. In order to aid the replacement decision process, several tool condition monitoring techniques are suggested. Force signals were shown in the literature to be strongly linked with tools flank wear. It can therefore be assumed that force signals are highly relevant for monitoring the condition of cutting tools and providing decision-aid information in the framework of their maintenance and replacement. The objective of this work is to correlate tools flank wear with numerically computed force signals. The present work uses a Finite Element Model with a Coupled Eulerian-Lagrangian approach. The geometry of the tool is changed for different runs of the model, in order to obtain results that are specific to a certain level of wear. The model is assessed by comparison with experimental data gathered earlier on fresh tools. Using the model at constant cutting parameters, force signals under different tool wear states are computed and provide force signals for each studied tool geometry. These signals are qualitatively compared with relevant data from the literature. At this point, no quantitative comparison could be performed on worn tools because the reviewed literature failed to provide similar studies in this material, either numerical or experimental. Therefore, further development of this work should include experimental campaigns aiming at collecting cutting forces signals and assessing the numerical results that were achieved through this work.

  16. Electron beam collimation with a photon MLC for standard electron treatments

    NASA Astrophysics Data System (ADS)

    Mueller, S.; Fix, M. K.; Henzen, D.; Frei, D.; Frauchiger, D.; Loessl, K.; Stampanoni, M. F. M.; Manser, P.

    2018-01-01

    Standard electron treatments are currently still performed using standard or molded patient-specific cut-outs placed in the electron applicator. Replacing cut-outs and electron applicators with a photon multileaf collimator (pMLC) for electron beam collimation would make standard electron treatments more efficient and would facilitate advanced treatment techniques like modulated electron radiotherapy (MERT) and mixed beam radiotherapy (MBRT). In this work, a multiple source Monte Carlo beam model for pMLC shaped electron beams commissioned at a source-to-surface distance (SSD) of 70 cm is extended for SSDs of up to 100 cm and validated for several Varian treatment units with field sizes typically used for standard electron treatments. Measurements and dose calculations agree generally within 3% of the maximal dose or 2 mm distance to agreement. To evaluate the dosimetric consequences of using pMLC collimated electron beams for standard electron treatments, pMLC-based and cut-out-based treatment plans are created for a left and a right breast boost, a sternum, a testis and a parotid gland case. The treatment plans consist of a single electron field, either alone (1E) or in combination with two 3D conformal tangential photon fields (1E2X). For each case, a pMLC plan with similar treatment plan quality in terms of dose homogeneity to the target and absolute mean dose values to the organs at risk (OARs) compared to a cut-out plan is found. The absolute mean dose to an OAR is slightly increased for pMLC-based compared to cut-out-based 1E plans if the OAR is located laterally close to the target with respect to beam direction, or if a 6 MeV electron beam is used at an extended SSD. In conclusion, treatment plans using cut-out collimation can be replaced by plans of similar treatment plan quality using pMLC collimation with accurately calculated dose distributions.

  17. Reliability analysis of a phaser measurement unit using a generalized fuzzy lambda-tau(GFLT) technique.

    PubMed

    Komal

    2018-05-01

    Nowadays power consumption is increasing day-by-day. To fulfill failure free power requirement, planning and implementation of an effective and reliable power management system is essential. Phasor measurement unit(PMU) is one of the key device in wide area measurement and control systems. The reliable performance of PMU assures failure free power supply for any power system. So, the purpose of the present study is to analyse the reliability of a PMU used for controllability and observability of power systems utilizing available uncertain data. In this paper, a generalized fuzzy lambda-tau (GFLT) technique has been proposed for this purpose. In GFLT, system components' uncertain failure and repair rates are fuzzified using fuzzy numbers having different shapes such as triangular, normal, cauchy, sharp gamma and trapezoidal. To select a suitable fuzzy number for quantifying data uncertainty, system experts' opinion have been considered. The GFLT technique applies fault tree, lambda-tau method, fuzzified data using different membership functions, alpha-cut based fuzzy arithmetic operations to compute some important reliability indices. Furthermore, in this study ranking of critical components of the system using RAM-Index and sensitivity analysis have also been performed. The developed technique may be helpful to improve system performance significantly and can be applied to analyse fuzzy reliability of other engineering systems. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  18. Laser cutting metallic plates using a 2kW direct diode laser source

    NASA Astrophysics Data System (ADS)

    Fallahi Sichani, E.; Hauschild, D.; Meinschien, J.; Powell, J.; Assunção, E. G.; Blackburn, J.; Khan, A. H.; Kong, C. Y.

    2015-07-01

    This paper investigates the feasibility of using a 2kW direct diode laser source for producing high-quality cuts in a variety of materials. Cutting trials were performed in a two-stage experimental procedure. The first phase of trials was based on a one-factor-at-a-time change of process parameters aimed at exploring the process window and finding a semi-optimum set of parameters for each material/thickness combination. In the second phase, a full factorial experimental matrix was performed for each material and thickness, as a result of which, the optimum cutting parameters were identified. Characteristic values of the optimum cuts were then measured as per BS EN ISO 9013:2002.

  19. DEGRADATION IN THE FATIGUE STRENGTH OF DENTIN BY DIAMOND BUR PREPARATIONS: IMPORTANCE OF CUTTING DIRECTION

    PubMed Central

    Majd, B.; Majd, H.; Porter, J.A.; Romberg, E.; Arola, D.

    2014-01-01

    The objectives of this investigation were to evaluate the degradation in fatigue strength of dentin by diamond bur preparations and to identify the importance of cutting direction. Three groups of coronal dentin specimens were prepared from unrestored 3rd molars, including a flaw free “control”, and two groups that received a diamond bur cutting treatment performed parallel or perpendicular to the specimen length. The specimens were subjected to static or cyclic flexural loading to failure and the results were compared with data for carbide bur cutting. Under static loading diamond bur cutting resulted in significantly flexure lower strength (p≤0.05) than the control for both cutting directions (from 154 MPa to approx. 124 MPa). However, there was no significant difference in the strength between the control and carbide bur treated specimens. Similarly, the fatigue strength of the diamond bur treated specimens was significantly lower (p≤0.0001) than that of the control for both cutting directions. Cutting in the perpendicular direction resulted in nearly 60% reduction to the endurance limit (from 44 MPa to 19 MPa). Based on the results, diamond bur cutting of cavity preparations causes a reduction in the fatigue strength of dentin, regardless of the cutting direction. To maintain the durability of dentin, cavity preparations introduced using diamond burs must be performed with appropriate cutting direction and followed by a finishing pass. PMID:25611951

  20. Cutting efficiency of diamond burs operated with electric high-speed dental handpiece on zirconia.

    PubMed

    Nakamura, Keisuke; Katsuda, Yusuke; Ankyu, Shuhei; Harada, Akio; Tenkumo, Taichi; Kanno, Taro; Niwano, Yoshimi; Egusa, Hiroshi; Milleding, Percy; Örtengren, Ulf

    2015-10-01

    Zirconia-based dental restorations are becoming used more commonly. However, limited attention has been given to the difficulties experienced, concerning cutting, in removing the restorations when needed. The aim of the present study was to compare the cutting efficiency of diamond burs, operated using an electric high-speed dental handpiece, on zirconia (Zir) with those on lithium disilicate glass-ceramic (LD) and leucite glass-ceramic (L). In addition, evaluation of the cutting efficiency of diamond burs on Zir of different thicknesses was performed. Specimens of Zir were prepared with thicknesses of 0.5, 1.0, 2.0, and 4.0 mm, and specimens of LD and L were prepared with a thickness of 1.0 mm. Cutting tests were performed using diamond burs with super coarse (SC) and coarse (C) grains. The handpiece was operated at 150,000 rpm with a cutting force of 0.9 N. The results demonstrated that cutting of Zir took about 1.5- and 7-fold longer than cutting of LD and L, respectively. The SC grains showed significantly higher cutting efficiency on Zir than the C grains. However, when the thickness of Zir increased, the cutting depth was significantly decreased. As it is suggested that cutting of zirconia is time consuming, this should be taken into consideration in advance when working with zirconia restorations. © 2015 Eur J Oral Sci.

  1. Degradation in the fatigue strength of dentin by diamond bur preparations: Importance of cutting direction.

    PubMed

    Majd, B; Majd, H; Porter, J A; Romberg, E; Arola, D

    2016-01-01

    The objectives of this investigation were to evaluate the degradation in fatigue strength of dentin by diamond bur preparations and to identify the importance of cutting direction. Three groups of coronal dentin specimens were prepared from unrestored third molars, including a flaw free "control," and two groups that received a diamond bur cutting treatment performed parallel or perpendicular to the specimen length. The specimens were subjected to static or cyclic flexural loading to failure and the results were compared with data for carbide bur cutting. Under static loading diamond bur cutting resulted in significantly lower flexure strength (p ≤ 0.05) than the control for both cutting directions (from 154 to ∼124 MPa). However, there was no significant difference in the strength between the control and carbide bur treated specimens. Similarly, the fatigue strength of the diamond bur treated specimens was significantly lower (p ≤ 0.0001) than that of the control for both cutting directions. Cutting in the perpendicular direction resulted in nearly 60% reduction to the endurance limit (from 44 to 19 MPa). Based on the results, diamond bur cutting of cavity preparations causes a reduction in the fatigue strength of dentin, regardless of the cutting direction. To maintain the durability of dentin, cavity preparations introduced using diamond burs must be performed with appropriate cutting direction and followed by a finishing pass. © 2014 Wiley Periodicals, Inc.

  2. Testing of an actively damped boring bar featuring structurally integrated PZT stack actuators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Redmond, J.; Barney, P.

    This paper summarizes the results of cutting tests performed using an actively damped boring bar to minimize chatter in metal cutting. A commercially available 2 inch diameter boring bar was modified to incorporate PZT stack actuators for controlling tool bending vibrations encountered during metal removal. The extensional motion of the actuators induce bending moments in the host structure through a two-point preloaded mounting scheme. Cutting tests performed at various speeds and depths of cuts on a hardened steel workpiece illustrate the bar`s effectiveness toward eliminating chatter vibrations and improving workpiece surface finish.

  3. Stress wave techniques for determining quality of dimensional lumber from switch ties

    Treesearch

    K. C. Schad; D. E. Kretschmann; K. A. McDonald; R. J. Ross; D. W. Green

    1995-01-01

    Researchers at the Forest Products Laboratory, USDA Forest Service, have been studying nondestructive techniques for evaluating the strength of wood. This report describes the results of a pilot study on using these techniques to determine the quality of large dimensional lumber cut from switch ties. First, pulse echo and dynamic (transverse vibration) techniques were...

  4. Characteristics of enhanced-mode AlGaN/GaN MIS HEMTs for millimeter wave applications

    NASA Astrophysics Data System (ADS)

    Lee, Jong-Min; Ahn, Ho-Kyun; Jung, Hyun-Wook; Shin, Min Jeong; Lim, Jong-Won

    2017-09-01

    In this paper, an enhanced-mode (E-mode) AlGaN/GaN high electron mobility transistor (HEMT) was developed by using 4-inch GaN HEMT process. We designed and fabricated Emode HEMTs and characterized device performance. To estimate the possibility of application for millimeter wave applications, we focused on the high frequency performance and power characteristics. To shift the threshold voltage of HEMTs we applied the Al2O3 insulator to the gate structure and adopted the gate recess technique. To increase the frequency performance the e-beam lithography technique was used to define the 0.15 um gate length. To evaluate the dc and high frequency performance, electrical characterization was performed. The threshold voltage was measured to be positive value by linear extrapolation from the transfer curve. The device leakage current is comparable to that of the depletion mode device. The current gain cut-off frequency and the maximum oscillation frequency of the E-mode device with a total gate width of 150 um were 55 GHz and 168 GHz, respectively. To confirm the power performance for mm-wave applications the load-pull test was performed. The measured power density of 2.32 W/mm was achieved at frequencies of 28 and 30 GHz.

  5. Robot based deposition of WC-Co HVOF coatings on HSS cutting tools as a substitution for solid cemented carbide cutting tools

    NASA Astrophysics Data System (ADS)

    Tillmann, W.; Schaak, C.; Biermann, D.; Aßmuth, R.; Goeke, S.

    2017-03-01

    Cemented carbide (hard metal) cutting tools are the first choice to machine hard materials or to conduct high performance cutting processes. Main advantages of cemented carbide cutting tools are their high wear resistance (hardness) and good high temperature strength. In contrast, cemented carbide cutting tools are characterized by a low toughness and generate higher production costs, especially due to limited resources. Usually, cemented carbide cutting tools are produced by means of powder metallurgical processes. Compared to conventional manufacturing routes, these processes are more expensive and only a limited number of geometries can be realized. Furthermore, post-processing and preparing the cutting edges in order to achieve high performance tools is often required. In the present paper, an alternative method to substitute solid cemented carbide cutting tools is presented. Cutting tools made of conventional high speed steels (HSS) were coated with thick WC-Co (88/12) layers by means of thermal spraying (HVOF). The challenge is to obtain a dense, homogenous, and near-net-shape coating on the flanks and the cutting edge. For this purpose, different coating strategies were realized using an industrial robot. The coating properties were subsequently investigated. After this initial step, the surfaces of the cutting tools were ground and selected cutting edges were prepared by means of wet abrasive jet machining to achieve a smooth and round micro shape. Machining tests were conducted with these coated, ground and prepared cutting tools. The occurring wear phenomena were analyzed and compared to conventional HSS cutting tools. Overall, the results of the experiments proved that the coating withstands mechanical stresses during machining. In the conducted experiments, the coated cutting tools showed less wear than conventional HSS cutting tools. With respect to the initial wear resistance, additional benefits can be obtained by preparing the cutting edge by means of wet abrasive jet machining.

  6. Optimizing cutting conditions on sustainable machining of aluminum alloy to minimize power consumption

    NASA Astrophysics Data System (ADS)

    Nur, Rusdi; Suyuti, Muhammad Arsyad; Susanto, Tri Agus

    2017-06-01

    Aluminum is widely utilized in the industrial sector. There are several advantages of aluminum, i.e. good flexibility and formability, high corrosion resistance and electrical conductivity, and high heat. Despite of these characteristics, however, pure aluminum is rarely used because of its lacks of strength. Thus, most of the aluminum used in the industrial sectors was in the form of alloy form. Sustainable machining can be considered to link with the transformation of input materials and energy/power demand into finished goods. Machining processes are responsible for environmental effects accepting to their power consumption. The cutting conditions have been optimized to minimize the cutting power, which is the power consumed for cutting. This paper presents an experimental study of sustainable machining of Al-11%Si base alloy that was operated without any cooling system to assess the capacity in reducing power consumption. The cutting force was measured and the cutting power was calculated. Both of cutting force and cutting power were analyzed and modeled by using the central composite design (CCD). The result of this study indicated that the cutting speed has an effect on machining performance and that optimum cutting conditions have to be determined, while sustainable machining can be followed in terms of minimizing power consumption and cutting force. The model developed from this study can be used for evaluation process and optimization to determine optimal cutting conditions for the performance of the whole process.

  7. High performance cutting of aircraft and turbine components

    NASA Astrophysics Data System (ADS)

    Krämer, A.; Lung, D.; Klocke, F.

    2012-04-01

    Titanium and nickel-based alloys belong to the group of difficult-to-cut materials. The machining of these high-temperature alloys is characterized by low productivity and low process stability as a result of their physical and mechanical properties. Major problems during the machining of these materials are low applicable cutting speeds due to excessive tool wear, long machining times, and thus high manufacturing costs, as well as the formation of ribbon and snarled chips. Under these conditions automation of the production process is limited. This paper deals with strategies to improve machinability of titanium and nickel-based alloys. Using the example of the nickel-based alloy Inconel 718 high performance cutting with advanced cutting materials, such as PCBN and cutting ceramics, is presented. Afterwards the influence of different cooling strategies, like high-pressure lubricoolant supply and cryogenic cooling, during machining of TiAl6V4 is shown.

  8. The cutting edge - Micro-CT for quantitative toolmark analysis of sharp force trauma to bone.

    PubMed

    Norman, D G; Watson, D G; Burnett, B; Fenne, P M; Williams, M A

    2018-02-01

    Toolmark analysis involves examining marks created on an object to identify the likely tool responsible for creating those marks (e.g., a knife). Although a potentially powerful forensic tool, knife mark analysis is still in its infancy and the validation of imaging techniques as well as quantitative approaches is ongoing. This study builds on previous work by simulating real-world stabbings experimentally and statistically exploring quantitative toolmark properties, such as cut mark angle captured by micro-CT imaging, to predict the knife responsible. In Experiment 1 a mechanical stab rig and two knives were used to create 14 knife cut marks on dry pig ribs. The toolmarks were laser and micro-CT scanned to allow for quantitative measurements of numerous toolmark properties. The findings from Experiment 1 demonstrated that both knives produced statistically different cut mark widths, wall angle and shapes. Experiment 2 examined knife marks created on fleshed pig torsos with conditions designed to better simulate real-world stabbings. Eight knives were used to generate 64 incision cut marks that were also micro-CT scanned. Statistical exploration of these cut marks suggested that knife type, serrated or plain, can be predicted from cut mark width and wall angle. Preliminary results suggest that knives type can be predicted from cut mark width, and that knife edge thickness correlates with cut mark width. An additional 16 cut marks walls were imaged for striation marks using scanning electron microscopy with results suggesting that this approach might not be useful for knife mark analysis. Results also indicated that observer judgements of cut mark shape were more consistent when rated from micro-CT images than light microscopy images. The potential to combine micro-CT data, medical grade CT data and photographs to develop highly realistic virtual models for visualisation and 3D printing is also demonstrated. This is the first study to statistically explore simulated real-world knife marks imaged by micro-CT to demonstrate the potential of quantitative approaches in knife mark analysis. Findings and methods presented in this study are relevant to both forensic toolmark researchers as well as practitioners. Limitations of the experimental methodologies and imaging techniques are discussed, and further work is recommended. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Combination of water-jet dissection and needle-knife as a hybrid knife simplifies endoscopic submucosal dissection.

    PubMed

    Lingenfelder, Tobias; Fischer, Klaus; Sold, Moritz G; Post, Stefan; Enderle, Markus D; Kaehler, Georg F B A

    2009-07-01

    The safety and efficacy of endoscopic submucosal dissection (ESD) is very dependent on an effective injection beneath the submucosal lamina and on a controlled cutting technique. After our study group demonstrated the efficacy of the HydroJet in needleless submucosal injections under various physical conditions to create a submucosal fluid cushion (Selective tissue elevation by pressure = STEP technique), the next step was to develop a new instrument to combine the capabilities of an IT-Knife with a high-pressure water-jet in a single instrument. In this experimental study, we compared this new instrument with a standard ESD technique. Twelve gastric ESD were performed in six pigs under endotracheal anesthesia. Square areas measuring 4-cm x 4-cm were marked out on the anterior and posterior wall in the corpus-antrum transition region. The HybridKnife was used as an standard needle knife with insulated tip (i.e., the submucosal injection was performed with an injection needle and only the radiofrequency (RF) part of the HybridKnife was used for cutting (conventional technique)) or the HybridKnife was used in all the individual stages of the ESD, making use of the HybridKnife's combined functions (HybridKnife technique). The size of the resected specimens, the operating time, the frequency with which instruments were changed, the number of bleeding episodes, and the number of injuries to the gastric wall together with the subjective overall assessment of the intervention by the operating physician were recorded. The resected specimens were the same size, with average sizes of 16.96 cm(2) and 15.85 cm(2) resp (p = 0.8125). Bleeding episodes have been less frequent in the HybridKnife group (2.83 vs. 3.5; p = 0.5625). The standard knife caused more injuries to the lamina muscularis propria (0.17 vs. 1.33; p = 0.0313). The operating times had a tendency to be shorter with the HybridKnife technique (47.18 vs. 58.32 minute; p = 0.0313). The combination of a needle-knife with high-pressure water-jet dissection improved the results of endoscopic submucosal dissection in this experimental setting. Because the frequency of complications is still high, further improvements to the instrument are necessary.

  10. Recognition of surgical skills using hidden Markov models

    NASA Astrophysics Data System (ADS)

    Speidel, Stefanie; Zentek, Tom; Sudra, Gunther; Gehrig, Tobias; Müller-Stich, Beat Peter; Gutt, Carsten; Dillmann, Rüdiger

    2009-02-01

    Minimally invasive surgery is a highly complex medical discipline and can be regarded as a major breakthrough in surgical technique. A minimally invasive intervention requires enhanced motor skills to deal with difficulties like the complex hand-eye coordination and restricted mobility. To alleviate these constraints we propose to enhance the surgeon's capabilities by providing a context-aware assistance using augmented reality techniques. To recognize and analyze the current situation for context-aware assistance, we need intraoperative sensor data and a model of the intervention. Characteristics of a situation are the performed activity, the used instruments, the surgical objects and the anatomical structures. Important information about the surgical activity can be acquired by recognizing the surgical gesture performed. Surgical gestures in minimally invasive surgery like cutting, knot-tying or suturing are here referred to as surgical skills. We use the motion data from the endoscopic instruments to classify and analyze the performed skill and even use it for skill evaluation in a training scenario. The system uses Hidden Markov Models (HMM) to model and recognize a specific surgical skill like knot-tying or suturing with an average recognition rate of 92%.

  11. The impact of feeding growing-finishing pigs with daily tailored diets using precision feeding techniques on animal performance, nutrient utilization, and body and carcass composition.

    PubMed

    Andretta, I; Pomar, C; Rivest, J; Pomar, J; Lovatto, P A; Radünz Neto, J

    2014-09-01

    The impact of moving from conventional to precision feeding systems in growing-finishing pig operations on animal performance, nutrient utilization, and body and carcass composition was studied. Fifteen animals per treatment for a total of 60 pigs of 41.2 (SE = 0.5) kg of BW were used in a performance trial (84 d) with 4 treatments: a 3-phase (3P) feeding program obtained by blending fixed proportions of feeds A (high nutrient density) and B (low nutrient density); a 3-phase commercial (COM) feeding program; and 2 daily-phase feeding programs in which the blended proportions of feeds A and B were adjusted daily to meet the estimated nutritional requirements of the group (multiphase-group feeding, MPG) or of each pig individually (multiphase-individual feeding, MPI). Daily feed intake was recorded each day and pigs were weighed weekly during the trial. Body composition was assessed at the beginning of the trial and every 28 d by dual-energy X-ray densitometry. Nitrogen and phosphorus excretion was estimated as the difference between retention and intake. Organ, carcass, and primal cut measurements were taken after slaughter. The COM feeding program reduced (P < 0.05) ADFI and improved G:F rate in relation to other treatments. The MPG and MPI programs showed values for ADFI, ADG, G:F, final BW, and nitrogen and phosphorus retention that were similar to those obtained for the 3P feeding program. However, compared with the 3P treatment, the MPI feeding program reduced the standardized ileal digestible lysine intake by 27%, the estimated nitrogen excretion by 22%, and the estimated phosphorus excretion by 27% (P < 0.05). Organs, carcass, and primal cut weights did not differ among treatments. Feeding growing-finishing pigs with daily tailored diets using precision feeding techniques is an effective approach to reduce nutrient excretion without compromising pig performance or carcass composition.

  12. Smart Cutting Tools and Smart Machining: Development Approaches, and Their Implementation and Application Perspectives

    NASA Astrophysics Data System (ADS)

    Cheng, Kai; Niu, Zhi-Chao; Wang, Robin C.; Rakowski, Richard; Bateman, Richard

    2017-09-01

    Smart machining has tremendous potential and is becoming one of new generation high value precision manufacturing technologies in line with the advance of Industry 4.0 concepts. This paper presents some innovative design concepts and, in particular, the development of four types of smart cutting tools, including a force-based smart cutting tool, a temperature-based internally-cooled cutting tool, a fast tool servo (FTS) and smart collets for ultraprecision and micro manufacturing purposes. Implementation and application perspectives of these smart cutting tools are explored and discussed particularly for smart machining against a number of industrial application requirements. They are contamination-free machining, machining of tool-wear-prone Si-based infra-red devices and medical applications, high speed micro milling and micro drilling, etc. Furthermore, implementation techniques are presented focusing on: (a) plug-and-produce design principle and the associated smart control algorithms, (b) piezoelectric film and surface acoustic wave transducers to measure cutting forces in process, (c) critical cutting temperature control in real-time machining, (d) in-process calibration through machining trials, (e) FE-based design and analysis of smart cutting tools, and (f) application exemplars on adaptive smart machining.

  13. Prospective analysis of a complete retrograde ureteroscopic technique with holmium laser stent cutting for management of encrusted ureteral stents.

    PubMed

    Thomas, Alexandre; Cloutier, Jonathan; Villa, Luca; Letendre, Julien; Ploumidis, Achilles; Traxer, Olivier

    2017-03-14

    To propose and evaluate a new endoscopic technique using only a retrograde ureteroscopic approach for the removal of heavily encrusted ureteral stents. Data from 51 consecutive patients with encrusted and retained ureteral stents were prospectively collected. Description of the successive steps of surgery is detailed. The Holmium-YAG laser properties offer the opportunity for fragmentation of stent-attached encrustation and the ability to cut the stent itself. Reducing the length of the stent is critical to creating space in the ureter and to allow free access for ureteroscopes or ureteral access sheath placement. The primary outcome of this study was the feasibility and the safety of this retrograde intra-renal approach. Some factors of encrustation and outcomes are also discussed in comparison with lithotripsy, percutaneous, laparoscopic, open surgery or a combination of these techniques. The removal of the encrusted stent was possible with only this retrograde technique in 98% of patients. The transection of the encrusted stent with the Holmium-YAG laser was useful in 71% of the patients. Mean operative time was 110 minutes and mean hospital stay was 2.33 days. Postoperative complications were mainly non-obstructive pyelonephritis (10%). The most significant predictor of this life threatened complication was the presence of struvite stones with the encrusted stent (p=0,018). Contrariwise, operative time, BMI, gender and encrustation rate were not associated with postoperative pyelonephritis. Cystine stone disease or pregnancy both led to faster stent encrustation. Retrograde ureteroscopic surgery is efficient and safe for removing retained stents and associated stone burdens. The Holmium-YAG laser is essential to perform the encrustation removal and sectioning of the stent.

  14. Sequential segmental terminal lenticular side-cut dissection for safe and effective small-incision lenticule extraction in thin lenticules.

    PubMed

    Jacob, Soosan; Agarwal, Amar; Mazzotta, Cosimo; Agarwal, Athiya; Raj, John Michael

    2017-04-01

    Small-incision lenticule extraction may be associated with complications such as partial lenticular dissection, torn lenticule, lenticular adherence to cap, torn cap, and sub-cap epithelial ingrowth, some of which are more likely to occur during low-myopia corrections. We describe sequential segmental terminal lenticular side-cut dissection to facilitate minimally traumatic and smooth lenticular extraction. Anterior lamellar dissection is followed by central posterior lamellar dissection, leaving a thin peripheral rim and avoiding the lenticular side cut. This is followed by sequential segmental dissection of the lenticular side cut in a manner that fixates the lenticule and provides sufficient resistance for smooth and complete dissection of the posterior lamellar cut without undesired movements of the lenticule. The technique is advantageous in thin lenticules, where the risk for complications is high, but can also be used in thick lenticular dissection using wider sweeps to separate the lenticular side cut sequentially. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  15. Freeform manufacturing of a microoptical lens array on a steep curved substrate by use of a voice coil fast tool servo.

    PubMed

    Scheiding, Sebastian; Yi, Allen Y; Gebhardt, Andreas; Li, Lei; Risse, Stefan; Eberhardt, Ramona; Tünnermann, Andreas

    2011-11-21

    We report what is to our knowledge the first approach to diamond turn microoptical lens array on a steep curved substrate by use of a voice coil fast tool servo. In recent years ultraprecision machining has been employed to manufacture accurate optical components with 3D structure for beam shaping, imaging and nonimaging applications. As a result, geometries that are difficult or impossible to manufacture using lithographic techniques might be fabricated using small diamond tools with well defined cutting edges. These 3D structures show no rotational symmetry, but rather high frequency asymmetric features thus can be treated as freeform geometries. To transfer the 3D surface data with the high frequency freeform features into a numerical control code for machining, the commonly piecewise differentiable surfaces are represented as a cloud of individual points. Based on this numeric data, the tool radius correction is calculated to account for the cutting-edge geometry. Discontinuities of the cutting tool locations due to abrupt slope changes on the substrate surface are bridged using cubic spline interpolation.When superimposed with the trajectory of the rotationally symmetric substrate the complete microoptical geometry in 3D space is established. Details of the fabrication process and performance evaluation are described. © 2011 Optical Society of America

  16. Automated tru-cut imaging-guided core needle biopsy of canine orbital neoplasia. A prospective feasibility study

    PubMed Central

    Cirla, A.; Rondena, M.; Bertolini, G.

    2016-01-01

    The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single centre. A complete ophthalmic examination was always followed by orbital ultrasound and computed tomography (CT) examination of the head. All masses were sampled with the patient still on the CT table using ultrasound (US) guided automatic tru-cut device. The most suitable sampling approach to the orbit was chosen each time based on the CT image analysis. One of the following different approaches was used: trans-orbital, trans-conjunctival or trans-masseteric. In all cases, the imaging-guided biopsy provided a sufficient amount of tissue for the histopathological diagnosis, which concurred with the biopsies obtained using the excisional technique. CT examination was essential for morphological diagnosis and provided detailed topographic information that allowed us to choose the safest orbital approach for the biopsy. US guided automatic tru-cut biopsy based on CT images, performed with patient still on the CT table, resulted in a minimally invasive, relatively easy, and accurate diagnostic procedure in dogs with orbital masses. PMID:27540512

  17. Automated tru-cut imaging-guided core needle biopsy of canine orbital neoplasia. A prospective feasibility study.

    PubMed

    Cirla, A; Rondena, M; Bertolini, G

    2016-01-01

    The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single centre. A complete ophthalmic examination was always followed by orbital ultrasound and computed tomography (CT) examination of the head. All masses were sampled with the patient still on the CT table using ultrasound (US) guided automatic tru-cut device. The most suitable sampling approach to the orbit was chosen each time based on the CT image analysis. One of the following different approaches was used: trans-orbital, trans-conjunctival or trans-masseteric. In all cases, the imaging-guided biopsy provided a sufficient amount of tissue for the histopathological diagnosis, which concurred with the biopsies obtained using the excisional technique. CT examination was essential for morphological diagnosis and provided detailed topographic information that allowed us to choose the safest orbital approach for the biopsy. US guided automatic tru-cut biopsy based on CT images, performed with patient still on the CT table, resulted in a minimally invasive, relatively easy, and accurate diagnostic procedure in dogs with orbital masses.

  18. Exploring JLA supernova data with improved flux-averaging technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Shuang; Wen, Sixiang; Li, Miao, E-mail: wangshuang@mail.sysu.edu.cn, E-mail: wensx@mail2.sysu.edu.cn, E-mail: limiao9@mail.sysu.edu.cn

    2017-03-01

    In this work, we explore the cosmological consequences of the ''Joint Light-curve Analysis'' (JLA) supernova (SN) data by using an improved flux-averaging (FA) technique, in which only the type Ia supernovae (SNe Ia) at high redshift are flux-averaged. Adopting the criterion of figure of Merit (FoM) and considering six dark energy (DE) parameterizations, we search the best FA recipe that gives the tightest DE constraints in the ( z {sub cut}, Δ z ) plane, where z {sub cut} and Δ z are redshift cut-off and redshift interval of FA, respectively. Then, based on the best FA recipe obtained, wemore » discuss the impacts of varying z {sub cut} and varying Δ z , revisit the evolution of SN color luminosity parameter β, and study the effects of adopting different FA recipe on parameter estimation. We find that: (1) The best FA recipe is ( z {sub cut} = 0.6, Δ z =0.06), which is insensitive to a specific DE parameterization. (2) Flux-averaging JLA samples at z {sub cut} ≥ 0.4 will yield tighter DE constraints than the case without using FA. (3) Using FA can significantly reduce the redshift-evolution of β. (4) The best FA recipe favors a larger fractional matter density Ω {sub m} . In summary, we present an alternative method of dealing with JLA data, which can reduce the systematic uncertainties of SNe Ia and give the tighter DE constraints at the same time. Our method will be useful in the use of SNe Ia data for precision cosmology.« less

  19. Research Results Of Stress-Strain State Of Cutting Tool When Aviation Materials Turning

    NASA Astrophysics Data System (ADS)

    Serebrennikova, A. G.; Nikolaeva, E. P.; Savilov, A. V.; Timofeev, S. A.; Pyatykh, A. S.

    2018-01-01

    Titanium alloys and stainless steels are hard-to-machine of all the machining types. Cutting edge state of turning tool after machining titanium and high-strength aluminium alloys and corrosion-resistant high-alloy steel has been studied. Cutting forces and chip contact arears with the rake surface of cutter has been measured. The relationship of cutting forces and residual stresses are shown. Cutting forces and residual stresses vs value of cutting tool rake angle relation were obtained. Measurements of residual stresses were performed by x-ray diffraction.

  20. Preparation of pre-cut corneas from fresh donated whole globes for Descemet's stripping automated keratoplasty: 3-year results at the Central Eye Bank of Iran.

    PubMed

    Kanavi, Mozhgan Rezaei; Javadi, Mohammad Ali; Javadi, Fatemeh; Chamani, Tahereh

    2014-09-01

    To describe the technique and the results of the preparation of pre-cut corneas for Descemet's stripping automated endothelial keratoplasty (DSAEK) during a 3-year period at the Central Eye Bank of Iran (CEBI). The method of preparation of pre-cut corneas from donated whole globes at the CEBI is described and the frequency and percentage of pre-cut corneas prepared for DSAEK, between April 2009 and March 2012, are specified. Moreover, post-operative reports are reviewed for any complaints about using pre-cut tissues for DSAEK. Out of the 1,518 donated whole globes appropriate for DSAEK, 1,478 (97.4 %) pre-cut corneas were successfully prepared. The method of preparation failed in 40 (2.6 %) cases. Based on the eye bank post-operative reports, thickness of pre-cut tissues for DSAEK was deemed unacceptable in only 6 (0.4 %) cases prior to surgery; five of these were too thick and one was too thin. Preparation of pre-cut corneas, for DSAEK from donated whole globes, in the CEBI is a safe and easy method, with very good preservation of endothelial cells after the preparation of the pre-cut corneas and reduced risks from corneal manipulation.

  1. Thermocouple and infrared sensor-based measurement of temperature distribution in metal cutting.

    PubMed

    Kus, Abdil; Isik, Yahya; Cakir, M Cemal; Coşkun, Salih; Özdemir, Kadir

    2015-01-12

    In metal cutting, the magnitude of the temperature at the tool-chip interface is a function of the cutting parameters. This temperature directly affects production; therefore, increased research on the role of cutting temperatures can lead to improved machining operations. In this study, tool temperature was estimated by simultaneous temperature measurement employing both a K-type thermocouple and an infrared radiation (IR) pyrometer to measure the tool-chip interface temperature. Due to the complexity of the machining processes, the integration of different measuring techniques was necessary in order to obtain consistent temperature data. The thermal analysis results were compared via the ANSYS finite element method. Experiments were carried out in dry machining using workpiece material of AISI 4140 alloy steel that was heat treated by an induction process to a hardness of 50 HRC. A PVD TiAlN-TiN-coated WNVG 080404-IC907 carbide insert was used during the turning process. The results showed that with increasing cutting speed, feed rate and depth of cut, the tool temperature increased; the cutting speed was found to be the most effective parameter in assessing the temperature rise. The heat distribution of the cutting tool, tool-chip interface and workpiece provided effective and useful data for the optimization of selected cutting parameters during orthogonal machining.

  2. Thermocouple and Infrared Sensor-Based Measurement of Temperature Distribution in Metal Cutting

    PubMed Central

    Kus, Abdil; Isik, Yahya; Cakir, M. Cemal; Coşkun, Salih; Özdemir, Kadir

    2015-01-01

    In metal cutting, the magnitude of the temperature at the tool-chip interface is a function of the cutting parameters. This temperature directly affects production; therefore, increased research on the role of cutting temperatures can lead to improved machining operations. In this study, tool temperature was estimated by simultaneous temperature measurement employing both a K-type thermocouple and an infrared radiation (IR) pyrometer to measure the tool-chip interface temperature. Due to the complexity of the machining processes, the integration of different measuring techniques was necessary in order to obtain consistent temperature data. The thermal analysis results were compared via the ANSYS finite element method. Experiments were carried out in dry machining using workpiece material of AISI 4140 alloy steel that was heat treated by an induction process to a hardness of 50 HRC. A PVD TiAlN-TiN-coated WNVG 080404-IC907 carbide insert was used during the turning process. The results showed that with increasing cutting speed, feed rate and depth of cut, the tool temperature increased; the cutting speed was found to be the most effective parameter in assessing the temperature rise. The heat distribution of the cutting tool, tool-chip interface and workpiece provided effective and useful data for the optimization of selected cutting parameters during orthogonal machining. PMID:25587976

  3. Study of the performances of nano-case treatment cutting tools on carbon steel work material during turning operation

    NASA Astrophysics Data System (ADS)

    Afolalu, S. A.; Okokpujie, I. P.; Salawu, E. Y.; Abioye, A. A.; Abioye, O. P.; Ikumapayi, O. M.

    2018-04-01

    The degree of holding temperature and time play a major role in nano-case treatment of cutting tools which immensely contributed to its performance during machining operation. The objective of this research work is to carryout comparative study of performance of nano-case treatment tools developed using low and medium carbon steel as work piece. Turning operation was carried out under two different categories with specific work piece on universal lathe machine using HSS cutting tools 100 mm × 12mm × 12mm that has been nano-case treated under varying conditions of temperatures and timeof 800,850, 900, 950°C and 60, 90, 120 mins respectively. The turning parameters used in evaluating this experiment were cutting speed of 270, 380 and 560mm/min, feed rate of 0.15, 0.20 and 0.25 mm/min, depth of cut of 2mm, work piece diameter of 25mm and rake angle of 7° each at three levels. The results of comparative study of their performances revealed that the timespent in the machining of low carbon steel material at a minimum temperature and time of 800°C, 60 mins were1.50, 2.17 mins while at maximum temperature and time of 950°C, 120 mins were 1.19, 2.02 mins. It was also observed that at a corresponding constant speed of 270,380 and 560mm/min at higher temperature and time, a relative increased in the length of cut were observed. Critical observation of the result showed that at higher case hardening temperature and time (950°C/120mins), the HSS cutting tool gave a better performance as lesser time was consumed during the turning operation.

  4. Leakage current and capacitance characteristics of Si/SiO2/Si single-barrier varactor

    NASA Astrophysics Data System (ADS)

    Mamor, M.; Fu, Y.; Nur, O.; Willander, M.; Bengtsson, S.

    We investigate, both experimentally and theoretically, current and capacitance (I-V/C-V) characteristics and the device performance of Si/SiO2/Si single-barrier varactor diodes (SBVs). Two diodes were fabricated with different SiO2 layer thicknesses using the state-of-the-art wafer bonding technique. The devices have very low leakage currents (about 5×10-2 and 1.8×10-2 mA/mm2) and intrinsic capacitance levels of typically 1.5 and 50 nF/mm2 for diodes with 5-nm and 20-nm oxide layers, respectively. With the present device physical parameters (25-mm2 device area, 760-μm modulation layer thickness and 1015-cm-3 doping level), the estimated cut-off frequency is about 5×107 Hz. With the physical parameters of the present existing III-V triplers, the cut-off frequency of our Si-based SBV can be as high as 0.5 THz.

  5. A cut-cell immersed boundary technique for fire dynamics simulation

    NASA Astrophysics Data System (ADS)

    Vanella, Marcos; McDermott, Randall; Forney, Glenn

    2015-11-01

    Fire simulation around complex geometry is gaining increasing attention in performance based design of fire protection systems, fire-structure interaction and pollutant transport in complex terrains, among others. This presentation will focus on our present effort in improving the capability of FDS (Fire Dynamics Simulator, developed at the Fire Research Division, NIST. https://github.com/firemodels/fds-smv) to represent fire scenarios around complex bodies. Velocities in the vicinity of the bodies are reconstructed using a classical immersed boundary scheme (Fadlun and co-workers, J. Comput. Phys., 161:35-60, 2000). Also, a conservative treatment of scalar transport equations (i.e. for chemical species) will be presented. In our method, discrete conservation and no penetration of species across solid boundaries are enforced using a cut-cell finite volume scheme. The small cell problem inherent to the method is tackled using explicit-implicit domain decomposition for scalar, within the FDS time integration scheme. Some details on the derivation, implementation and numerical tests of this numerical scheme will be discussed.

  6. A Novel Design Framework for Structures/Materials with Enhanced Mechanical Performance

    PubMed Central

    Liu, Jie; Fan, Xiaonan; Wen, Guilin; Qing, Qixiang; Wang, Hongxin; Zhao, Gang

    2018-01-01

    Structure/material requires simultaneous consideration of both its design and manufacturing processes to dramatically enhance its manufacturability, assembly and maintainability. In this work, a novel design framework for structural/material with a desired mechanical performance and compelling topological design properties achieved using origami techniques is presented. The framework comprises four procedures, including topological design, unfold, reduction manufacturing, and fold. The topological design method, i.e., the solid isotropic material penalization (SIMP) method, serves to optimize the structure in order to achieve the preferred mechanical characteristics, and the origami technique is exploited to allow the structure to be rapidly and easily fabricated. Topological design and unfold procedures can be conveniently completed in a computer; then, reduction manufacturing, i.e., cutting, is performed to remove materials from the unfolded flat plate; the final structure is obtained by folding out the plate from the previous procedure. A series of cantilevers, consisting of origami parallel creases and Miura-ori (usually regarded as a metamaterial) and made of paperboard, are designed with the least weight and the required stiffness by using the proposed framework. The findings here furnish an alternative design framework for engineering structures that could be better than the 3D-printing technique, especially for large structures made of thin metal materials. PMID:29642555

  7. A Novel Design Framework for Structures/Materials with Enhanced Mechanical Performance.

    PubMed

    Liu, Jie; Fan, Xiaonan; Wen, Guilin; Qing, Qixiang; Wang, Hongxin; Zhao, Gang

    2018-04-09

    Abstract : Structure/material requires simultaneous consideration of both its design and manufacturing processes to dramatically enhance its manufacturability, assembly and maintainability. In this work, a novel design framework for structural/material with a desired mechanical performance and compelling topological design properties achieved using origami techniques is presented. The framework comprises four procedures, including topological design, unfold, reduction manufacturing, and fold. The topological design method, i.e., the solid isotropic material penalization (SIMP) method, serves to optimize the structure in order to achieve the preferred mechanical characteristics, and the origami technique is exploited to allow the structure to be rapidly and easily fabricated. Topological design and unfold procedures can be conveniently completed in a computer; then, reduction manufacturing, i.e., cutting, is performed to remove materials from the unfolded flat plate; the final structure is obtained by folding out the plate from the previous procedure. A series of cantilevers, consisting of origami parallel creases and Miura-ori (usually regarded as a metamaterial) and made of paperboard, are designed with the least weight and the required stiffness by using the proposed framework. The findings here furnish an alternative design framework for engineering structures that could be better than the 3D-printing technique, especially for large structures made of thin metal materials.

  8. Smear layer production by 3 rotary reamers with different cutting blade designs in straight root canals: a scanning electron microscopic study.

    PubMed

    Jeon, In-Soo; Spångberg, Larz S W; Yoon, Tai-Cheol; Kazemi, Reza B; Kum, Kee-Yeon

    2003-11-01

    The design of the cutting blade of rotary instruments may affect the outcome of root canal instrumentation in terms of cleanliness. The aim of this scanning electron microscopic study was to compare the quality and amount of smear layer generated in the apical third of straight root canals by 2 rotary nickel-titanium reamers and 1 rotary steel reamer with different cutting blade designs. Seventy intact, single-rooted human mandibular premolars with straight, fully developed roots were selected for this study. Before instrumentation, the cervical portion of all teeth was removed by using a microtome (Isomet), leaving 13-mm-long roots. Automated preparation was performed with ProFile (n = 20) and Hero 642 (n = 20) reamers by using the crown-down technique and with a stainless steel engine reamer (Mani; n = 20) by using a reaming motion. All root canals were instrumented to No. 40. A control group (pulp extirpation with barbed broaches; n = 10) was also included. Irrigation with 3 mL of a 1% sodium hypochlorite (NaOCl) solution was performed after each instrumentation. After the instrumentation, each root was split longitudinally, and a scanning electron microscope was used to examine the selected areas of the canal walls at the apical third from 2 different perspectives. A 4-category scoring system for smear layer was used, and the resulting scores were statistically analyzed. The least smear layer remained in the Hero 642 group at the selected apical third of straight root canals (P < .05). However, all instruments left a smear layer. The surface texture of the smear layer, in addition to the depth and the frequency of packed materials into the dentinal tubules, varied with instrument type. These data revealed that the design of the cutting blade of rotary instruments can affect root canal cleanliness in straight root canals. This information may be useful in the selection of nickel-titanium rotary reamers.

  9. An improved FIB sample preparation technique for site-specific plan-view specimens: A new cutting geometry.

    PubMed

    Li, Chen; Habler, Gerlinde; Baldwin, Lisa C; Abart, Rainer

    2018-01-01

    Focused ion beam (FIB) sample preparation technique in plan-view geometry allows direct correlations of the atomic structure study via transmission electron microscopy with micrometer-scale property measurements. However, one main technical difficulty is that a large amount of material must be removed underneath the specimen. Furthermore, directly monitoring the milling process is difficult unless very large material volumes surrounding the TEM specimen site are removed. In this paper, a new cutting geometry is introduced for FIB lift-out sample preparation with plan-view geometry. Firstly, an "isolated" cuboid shaped specimen is cut out, leaving a "bridge" connecting it with the bulk material. Subsequently the two long sides of the "isolated" cuboid are wedged, forming a triangular prism shape. A micromanipulator needle is used for in-situ transfer of the specimen to a FIB TEM grid, which has been mounted parallel with the specimen surface using a simple custom-made sample slit. Finally, the grid is transferred to the standard FIB grid holder for final thinning with standard procedures. This new cutting geometry provides clear viewing angles for monitoring the milling process, which solves the difficulty of judging whether the specimen has been entirely detached from the bulk material, with the least possible damage to the surrounding materials. With an improved success rate and efficiency, this plan-view FIB lift-out specimen preparation technique should have a wide application for material science. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  10. Evaluating the effects of pinyon thinning treatments at a wildland urban interface

    Treesearch

    J. R. Matchett; Matthew Brooks; Anne Halford; Dale Johnson; Helen Smith

    2010-01-01

    This study evaluated the short-term effects of thinning methods for pinyon pine woodlands at two sites in the southwestern Great Basin. Both cut/pile/burn and mastication treatments were equally effective at reducing the target fuels which were mature, live pinyon trees. Application costs though differed substantially, with the cut/pile/burn technique being less...

  11. Uneven-aged management of old-growth spruce-fir forests: Cutting methods and stand structure goals for the initial entry

    Treesearch

    Robert R. Alexander; Carleton B. Edminster

    1977-01-01

    Topics discussed include: (1) cutting methods, (2) stand structure goals, which involve choosing a residual stocking level, selecting a maximum tree size, and establishing a diameter distribution using the "q" technique, and (3) harvesting and removal of trees. Examples illustrate how to determine realistic stand structures for the initial entry for...

  12. Sampling tree tops by helicopter...special pole pruner cuts branchlets

    Treesearch

    John F. Wear; Robert G. Winterfeld

    1966-01-01

    A new technique for sampling tops of tall Douglas-fir trees by using a special pole pruner from a helicopter has been developed and field-tested. Thee pole pruner cuts and holds a branchlet. Foliage samples collected will be compared by spectral analysis to show the type of aerial imagery that best differentiates healthy trees from those attacked by root rot.

  13. Calculation of Water Entry Problem for Free-falling Bodies Using a Developed Cartesian Cut Cell Mesh

    NASA Astrophysics Data System (ADS)

    Wenhua, Wang; Yanying, Wang

    2010-05-01

    This paper describes the development of free surface capturing method on Cartesian cut cell mesh to water entry problem for free-falling bodies with body-fluid interaction. The incompressible Euler equations for a variable density fluid system are presented as governing equations and the free surface is treated as a contact discontinuity by using free surface capturing method. In order to be convenient for dealing with the problem with moving body boundary, the Cartesian cut cell technique is adopted for generating the boundary-fitted mesh around body edge by cutting solid regions out of a background Cartesian mesh. Based on this mesh system, governing equations are discretized by finite volume method, and at each cell edge inviscid flux is evaluated by means of Roe's approximate Riemann solver. Furthermore, for unsteady calculation in time domain, a time accurate solution is achieved by a dual time-stepping technique with artificial compressibility method. For the body-fluid interaction, the projection method of momentum equations and exact Riemann solution are applied in the calculation of fluid pressure on the solid boundary. Finally, the method is validated by test case of water entry for free-falling bodies.

  14. An Experimental Study on Micro Clinching of Metal Foils with Cutting by Laser Shock Forming.

    PubMed

    Wang, Xiao; Li, Cong; Ma, Youjuan; Shen, Zongbao; Sun, Xianqing; Sha, Chaofei; Gao, Shuai; Li, Liyin; Liu, Huixia

    2016-07-13

    This paper describes a novel technique for joining similar and dissimilar metal foils, namely micro clinching with cutting by laser shock forming. A series of experiments were conducted to study the deformation behavior of single layer material, during which many important process parameters were determined. The process window of the 1060 pure aluminum foils and annealed copper foils produced by micro clinching with cutting was analyzed. Moreover, similar material combination (annealed copper foils) and dissimilar material combination (1060 pure aluminum foils and 304 stainless steel foils) were successfully achieved. The effect of laser energy on the interlock and minimum thickness of upper foils was investigated. In addition, the mechanical strength of different material combinations joined by micro clinching with cutting was measured in single lap shearing tests. According to the achieved results, this novel technique is more suitable for material combinations where the upper foil is thicker than lower foil. With the increase of laser energy, the interlock increased while the minimum thickness of upper foil decreased gradually. The shear strength of 1060 pure aluminum foils and 304 stainless steel foils combination was three times as large as that of 1060 pure aluminum foils and annealed copper foils combination.

  15. Development of methods of producing large areas of silicon sheet by the slicing of silicon ingots using Inside Diameter (I.D.) saws

    NASA Technical Reports Server (NTRS)

    Aharonyan, P.

    1980-01-01

    Modifications to a 16 inch STC automated saw included: a programmable feed system; a crystal rotating system; and a STC dynatrack blade boring and control system. By controlling the plating operation and by grinding the cutting edge, 16 inch I.D. blades were produced with a cutting edge thickness of .22 mm. Crystal rotation mechanism was used to slice 100 mm diameter crystals with a 16 inch blade down to a thickness of .20 mm. Cutting rates with crystal rotation were generally slower than with standard plunge I.D. slicing techniques. Using programmed feeds and programmed rotation, maximum cutting rates were from 0.3 to 1.0 inches per minute.

  16. Study on development system of increasing gearbox for high-performance wind-power generator

    NASA Astrophysics Data System (ADS)

    Xu, Hongbin; Yan, Kejun; Zhao, Junyu

    2005-12-01

    Based on the analysis of the development potentiality of wind-power generator and domestic manufacture of its key parts in China, an independent development system of the Increasing Gearbox for High-performance Wind-power Generator (IGHPWG) was introduced. The main elements of the system were studied, including the procedure design, design analysis system, manufacturing technology and detecting system, and the relative important technologies were analyzed such as mixed optimal joint transmission structure of the first planetary drive with two grade parallel axle drive based on equal strength, tooth root round cutting technology before milling hard tooth surface, high-precise tooth grinding technology, heat treatment optimal technology and complex surface technique, and rig test and detection technique of IGHPWG. The development conception was advanced the data share and quality assurance system through all the elements of the development system. The increasing Gearboxes for 600KW and 1MW Wind-power Generator have been successfully developed through the application of the development system.

  17. Rapid spontaneous Raman light sheet microscopy using cw-lasers and tunable filters

    PubMed Central

    Rocha-Mendoza, Israel; Licea-Rodriguez, Jacob; Marro, Mónica; Olarte, Omar E.; Plata-Sanchez, Marcos; Loza-Alvarez, Pablo

    2015-01-01

    We perform rapid spontaneous Raman 2D imaging in light-sheet microscopy using continuous wave lasers and interferometric tunable filters. By angularly tuning the filter, the cut-on/off edge transitions are scanned along the excited Stokes wavelengths. This allows obtaining cumulative intensity profiles of the scanned vibrational bands, which are recorded on image stacks; resembling a spectral version of the knife-edge technique to measure intensity profiles. A further differentiation of the stack retrieves the Raman spectra at each pixel of the image which inherits the 3D resolution of the host light sheet system. We demonstrate this technique using solvent solutions and composites of polystyrene beads and lipid droplets immersed in agar and by imaging the C–H (2800-3100cm−1) region in a C. elegans worm. The image acquisition time results in 4 orders of magnitude faster than confocal point scanning Raman systems, allowing the possibility of performing fast spontaneous Raman·3D-imaging on biological samples. PMID:26417514

  18. Electro-chemical grinding

    NASA Technical Reports Server (NTRS)

    Feagans, P. L.

    1972-01-01

    Electro-chemical grinding technique has rotation speed control, constant feed rates, and contour control. Hypersonic engine parts of nickel alloys can be almost 100% machined, keeping tool pressure at virtual zero. Technique eliminates galling and permits constant surface finish and burr-free interrupted cutting.

  19. Anticipatory postural adjustments during cutting manoeuvres in football and their consequences for knee injury risk.

    PubMed

    Mornieux, Guillaume; Gehring, Dominic; Fürst, Patrick; Gollhofer, Albert

    2014-01-01

    Anticipatory postural adjustments (APAs), i.e. preparatory positioning of the head, the trunk and the foot, are essential to initiate cutting manoeuvres during football games. The aim of the present study was to determine how APA strategies during cutting manoeuvres are influenced by a reduction of the time available to prepare the movement. Thirteen football players performed different cutting tasks, with directions of cutting either known prior to the task or indicated by a light signal occurring 850, 600 or 500 ms before ground contact. With less time available to prepare the cutting manoeuvre, the head was less orientated towards the cutting direction (P = 0.033) and the trunk was even more rotated in the opposite direction (P = 0.002), while the foot placement was not significantly influenced. Moreover, the induced higher lateral trunk flexion correlated with the increased knee abduction moment (r = 0.41; P = 0.009). Increasing lateral trunk flexion is the main strategy used to successfully perform a cutting manoeuvre when less time is available to prepare the movement. However, higher lateral trunk flexion was associated with an increased knee abduction moment and therefore an increased knee injury risk. Reducing lateral trunk flexion during cutting manoeuvres should be part of training programs seeking the optimisation of APAs.

  20. Planting Depth and Source Affect Survival of Planted Green Ash Cuttings

    Treesearch

    Harvey E. Kennedy

    1977-01-01

    Horizontally and vertically planted cuttings from 1-0 nursery-grown green ash seedlings sprouted and grew well during the first growing season. Cuttings from 1- and 2-year-old sprouts and older material did not perform satisfactorily. Planted seedlings survived and grew well. Cuttings should be 10 to 15 inches long made from 1-0 seedlings and planted horizontally in...

  1. Paraffin tissue microarrays constructed with a cutting board and cutting board arrayer.

    PubMed

    Vogel, Ulrich Felix

    2010-05-01

    Paraffin tissue microarrays (PTMAs) are blocks of paraffin containing up to 1300 paraffin tissue core biopsies (PTCBs). Normally, these PTCBs are punched from routine paraffin tissue blocks, which contain tissues of differing thicknesses. Therefore, the PTCBs are of different lengths. In consequence, the sections of the deeper portions of the PTMA do not contain all of the desired PTCBs. To overcome this drawback, cutting boards were constructed from panels of plastic with a thickness of 4 mm. Holes were drilled into the plastic and filled completely with at least one PTCB per hole. After being trimmed to a uniform length of 4 mm, these PTCBs were pushed from the cutting board into corresponding holes in a recipient block by means of a plate with steel pins. Up to 1000 sections per PTMA were cut without any significant loss of PTCBs, thereby increasing the efficacy of the PTMA technique.

  2. Application of Taguchi Method for Analyzing Factors Affecting the Performance of Coated Carbide Tool When Turning FCD700 in Dry Cutting Condition

    NASA Astrophysics Data System (ADS)

    Ghani, Jaharah A.; Mohd Rodzi, Mohd Nor Azmi; Zaki Nuawi, Mohd; Othman, Kamal; Rahman, Mohd. Nizam Ab.; Haron, Che Hassan Che; Deros, Baba Md

    2011-01-01

    Machining is one of the most important manufacturing processes in these modern industries especially for finishing an automotive component after the primary manufacturing processes such as casting and forging. In this study the turning parameters of dry cutting environment (without air, normal air and chilled air), various cutting speed, and feed rate are evaluated using a Taguchi optimization methodology. An orthogonal array L27 (313), signal-to-noise (S/N) ratio and analysis of variance (ANOVA) are employed to analyze the effect of these turning parameters on the performance of a coated carbide tool. The results show that the tool life is affected by the cutting speed, feed rate and cutting environment with contribution of 38%, 32% and 27% respectively. Whereas for the surface roughness, the feed rate is significantly controlled the machined surface produced by 77%, followed by the cutting environment of 19%. The cutting speed is found insignificant in controlling the machined surface produced. The study shows that the dry cutting environment factor should be considered in order to produce longer tool life as well as for obtaining a good machined surface.

  3. Cutting moments and grip forces in meat cutting operations and the effect of knife sharpness.

    PubMed

    McGorry, Raymond W; Dowd, Peter C; Dempsey, Patrick G

    2003-07-01

    The force exposure associated with meat cutting operations and the effect of knife sharpness on performance and productivity have not been well documented. Specialized hardware was used to measure grip force and reactive moments with 15 professional meat cutters performing lamb shoulder boning, beef rib trimming and beef loin trim operations in a field study conducted in two meat packing plants. A system for measuring relative blade sharpness was developed for this study. Mean and peak cutting moments observed for the meat cutting operations, averaged across subjects were 4.7 and 17.2 Nm for the shoulder boning, 3.5 and 12.9 Nm for the rib trim, and 2.3 and 10.6 Nm for the loin trim, respectively. Expressed as percent of MVC, mean grip forces of 28.3% and peak grip forces of 72.6% were observed overall. Blade sharpness was found to effect grip forces, cutting moments and cutting time, with sharper blades requiring statistically significantly lower peak and mean cutting moments, and grip forces than dull knives. Efforts aimed at providing and maintaining sharp blades could have a significant impact on force exposure.

  4. The Constant Intensity Cut Method applied to the KASCADE-Grande muon data

    NASA Astrophysics Data System (ADS)

    Arteaga-Velázquez, J. C.; Apel, W. D.; Badea, F.; Bekk, K.; Bertaina, M.; Blümer, J.; Bozdog, H.; Brancus, I. M.; Brüggemann, M.; Buchholz, P.; Cantoni, E.; Chiavassa, A.; Cossavella, F.; Daumiller, K.; de Souza, V.; Di Pierro, F.; Doll, P.; Engel, R.; Engler, J.; Finger, M.; Fuhrmann, D.; Ghia, P. L.; Gils, H. J.; Glasstetter, R.; Grupen, C.; Haungs, A.; Heck, D.; Hörandel, J. R.; Huege, T.; Isar, P. G.; Kampert, K.-H.; Kang, D.; Kickelbick, D.; Klages, H. O.; Kolotaev, Y.; Łuczak, P.; Mathes, H. J.; Mayer, H. J.; Milke, J.; Mitrica, B.; Morello, C.; Navarra, G.; Nehls, S.; Oehlschläger, J.; Ostapchenko, S.; Over, S.; Petcu, M.; Pierog, T.; Rebel, H.; Roth, M.; Schieler, H.; Schröder, F.; Sima, O.; Stümpert, M.; Toma, G.; Trinchero, G.; Ulrich, H.; Walkowiak, W.; Weindl, A.; Wochele, J.; Wommer, M.; Zabierowski, J.

    2009-12-01

    The constant intensity cut method is a very useful tool to reconstruct the cosmic ray energy spectrum in order to combine or compare extensive air shower data measured for different attenuation depths independently of the MC model. In this contribution the method is used to explore the muon data of the KASCADE-Grande experiment. In particular, with this technique, the measured muon number spectra for different zenith angle ranges are compared and summed up to obtain a single muon spectrum for the measured showers. Preliminary results are presented, along with estimations of the systematic uncertainties associated with the analysis technique.

  5. Flow visualization over a thick blunt trailing-edge airfoil with base cavity at low Reynolds numbers using PIV technique.

    PubMed

    Taherian, Gholamhossein; Nili-Ahmadabadi, Mahdi; Karimi, Mohammad Hassan; Tavakoli, Mohammad Reza

    2017-01-01

    In this study, the effect of cutting the end of a thick airfoil and adding a cavity on its flow pattern is studied experimentally using PIV technique. First, by cutting 30% chord length of the Riso airfoil, a thick blunt trialing-edge airfoil is generated. The velocity field around the original airfoil and the new airfoil is measured by PIV technique and compared with each other. Then, adding two parallel plates to the end of the new airfoil forms the desired cavity. Continuous measurement of unsteady flow velocity over the Riso airfoil with thick blunt trailing edge and base cavity is the most important innovation of this research. The results show that cutting off the end of the airfoil decreases the wake region behind the airfoil, when separation occurs. Moreover, adding a cavity to the end of the thickened airfoil causes an increase in momentum and a further decrease in the wake behind the trailing edge that leads to a drag reduction in comparison with the thickened airfoil without cavity. Furthermore, using cavity decreases the Strouhal number and vortex shedding frequency.

  6. Micro-structural characterization of precipitation-synthesized fluorapatite nano-material by transmission electron microscopy using different sample preparation techniques.

    PubMed

    Chinthaka Silva, G W; Ma, Longzhou; Hemmers, Oliver; Lindle, Dennis

    2008-01-01

    Fluorapatite is a naturally occurring mineral of the apatite group and it is well known for its high physical and chemical stability. There is a recent interest in this ceramic to be used as a radioactive waste form material due to its intriguing chemical and physical properties. In this study, the nano-sized fluorapatite particles were synthesized using a precipitation method and the material was characterized using X-ray diffraction (XRD) and transmission electron microscopy (TEM). Two well-known methods, called solution-drop and the microtome cutting, were used to prepare the sample for TEM analysis. It was found that the microtome cutting technique is advantageous for examining the particle shape and cross-sectional morphology as well as for obtaining ultra-thin samples. However, this method introduces artifacts and strong background contrast for high-resolution transmission electron microscopy (HRTEM) observation. On the other hand, phase image simulations showed that the solution-drop method is reliable and stable for HRTEM analysis. Therefore, in order to comprehensively analyze the microstructure and morphology of the nano-material, it is necessary to combine both solution-drop and microtome cutting techniques for TEM sample preparation.

  7. An Experimental Study of Cutting Performances of Worn Picks

    NASA Astrophysics Data System (ADS)

    Dogruoz, Cihan; Bolukbasi, Naci; Rostami, Jamal; Acar, Cemil

    2016-01-01

    The best means to assess rock cuttability and efficiency of cutting process for using mechanical excavation is specific energy (SE), measured in full-scale rock cutting test. This is especially true for the application of roadheaders, often fitted with drag-type cutting tools. Radial picks or drag bits are changed during the operation as they reach a certain amount of wear and become blunt. In this study, full-scale cutting tests in different sedimentary rock types with bits having various degree of wear were used to evaluate the influence of bit wear on cutting forces and specific energy. The relationship between the amount of wear as represented by the size of the wear flats at the tip of the bit, and cutting forces as well as specific energy was examined. The influence of various rock properties such as mineral content, uniaxial compressive strength, tensile strength, indentation index, shore hardness, Schmidt hammer hardness, and density with required SE of cutting using different levels of tool wear was also studied. The preliminary analysis of the data shows that the mean cutting forces increase 2-3 times and SE by 4-5 times when cutting with 4 mm wear flat as compared to cutting with new or sharp wedge shape bits. The grain size distribution of the muck for cutting different rock types and different level of bit wear was analyzed and discussed. The best fit prediction models for SE based on statistical analysis of laboratory test results are introduced. The model can be used for estimating the performance of mechanical excavators using radial tools, especially roadheaders, continuous miners and longwall drum shearers.

  8. Piezosurgery for the lingual split technique in mandibular third molar removal: a suggestion.

    PubMed

    Pippi, Roberto; Alvaro, Roberto

    2013-03-01

    The lingual split technique is a surgical procedure for extraction of impacted mandibular third molar throughout a lingual approach. The main disadvantage of this technique is the high rate of temporary lingual nerve injury mainly because of the trauma induced by the lingual flap retraction. The purpose of this paper is to suggest the use of piezosurgery in performing the lingual cortical plate osteotomy of the third molar alveolar process. Surgical procedure was performed under general anesthesia, and it lasted approximately 60 minutes. After the buccal and lingual full-thickness flaps were incised and elevated, a piezosurgical device was used for osteotomy. A well-defined bony window was then removed, and it allowed the entire tooth was extracted in a lingual direction. The patient did not show any neurological postoperative complication. Lingual and inferior alveolar nerve functionality was normal before as well as after surgery. The use of piezoelectric surgery seems to be a good option in removing lower third molars when a lingual access is clearly indicated. The only disadvantage of this technique can be represented by an operating time lengthening possibly because of a lower power cut of the piezoelectric device, to the high mineralization of the mandibular cortical bone and to the use of inserts with a low degree of sharpening.

  9. Comparison of the fit of cast gold crowns fabricated from the digital and the conventional impression techniques

    PubMed Central

    Jeon, Young-Chan; Jeong, Chang-Mo

    2017-01-01

    PURPOSE The purpose of this study was to compare the fit of cast gold crowns fabricated from the conventional and the digital impression technique. MATERIALS AND METHODS Artificial tooth in a master model and abutment teeth in ten patients were restored with cast gold crowns fabricated from the digital and the conventional impression technique. The forty silicone replicas were cut in three sections; each section was evaluated in nine points. The measurement was carried out by using a measuring microscope and I-Soultion. Data from the silicone replica were analyzed and all tests were performed with α-level of 0.05. RESULTS 1. The average gaps of cast gold crowns fabricated from the digital impression technique were larger than those of the conventional impression technique significantly. 2. In marginal and internal axial gap of cast gold crowns, no statistical differences were found between the two impression techniques. 3. The internal occlusal gaps of cast gold crowns fabricated from the digital impression technique were larger than those of the conventional impression technique significantly. CONCLUSION Both prostheses presented clinically acceptable results with comparing the fit. The prostheses fabricated from the digital impression technique showed more gaps, in respect of occlusal surface. PMID:28243386

  10. Study of PVD AlCrN Coating for Reducing Carbide Cutting Tool Deterioration in the Machining of Titanium Alloys.

    PubMed

    Cadena, Natalia L; Cue-Sampedro, Rodrigo; Siller, Héctor R; Arizmendi-Morquecho, Ana M; Rivera-Solorio, Carlos I; Di-Nardo, Santiago

    2013-05-24

    The manufacture of medical and aerospace components made of titanium alloys and other difficult-to-cut materials requires the parallel development of high performance cutting tools coated with materials capable of enhanced tribological and resistance properties. In this matter, a thin nanocomposite film made out of AlCrN (aluminum-chromium-nitride) was studied in this research, showing experimental work in the deposition process and its characterization. A heat-treated monolayer coating, competitive with other coatings in the machining of titanium alloys, was analyzed. Different analysis and characterizations were performed on the manufactured coating by scanning electron microscopy and energy-dispersive X-ray spectroscopy (SEM-EDXS), and X-ray diffraction (XRD). Furthermore, the mechanical behavior of the coating was evaluated through hardness test and tribology with pin-on-disk to quantify friction coefficient and wear rate. Finally, machinability tests using coated tungsten carbide cutting tools were executed in order to determine its performance through wear resistance, which is a key issue of cutting tools in high-end cutting at elevated temperatures. It was demonstrated that the specimen (with lower friction coefficient than previous research) is more efficient in machinability tests in Ti6Al4V alloys. Furthermore, the heat-treated monolayer coating presented better performance in comparison with a conventional monolayer of AlCrN coating.

  11. Study of PVD AlCrN Coating for Reducing Carbide Cutting Tool Deterioration in the Machining of Titanium Alloys

    PubMed Central

    Cadena, Natalia L.; Cue-Sampedro, Rodrigo; Siller, Héctor R.; Arizmendi-Morquecho, Ana M.; Rivera-Solorio, Carlos I.; Di-Nardo, Santiago

    2013-01-01

    The manufacture of medical and aerospace components made of titanium alloys and other difficult-to-cut materials requires the parallel development of high performance cutting tools coated with materials capable of enhanced tribological and resistance properties. In this matter, a thin nanocomposite film made out of AlCrN (aluminum–chromium–nitride) was studied in this research, showing experimental work in the deposition process and its characterization. A heat-treated monolayer coating, competitive with other coatings in the machining of titanium alloys, was analyzed. Different analysis and characterizations were performed on the manufactured coating by scanning electron microscopy and energy-dispersive X-ray spectroscopy (SEM-EDXS), and X-ray diffraction (XRD). Furthermore, the mechanical behavior of the coating was evaluated through hardness test and tribology with pin-on-disk to quantify friction coefficient and wear rate. Finally, machinability tests using coated tungsten carbide cutting tools were executed in order to determine its performance through wear resistance, which is a key issue of cutting tools in high-end cutting at elevated temperatures. It was demonstrated that the specimen (with lower friction coefficient than previous research) is more efficient in machinability tests in Ti6Al4V alloys. Furthermore, the heat-treated monolayer coating presented better performance in comparison with a conventional monolayer of AlCrN coating. PMID:28809266

  12. HLRW management during MR reactor decommissioning in NRC 'Kurchatov Institute'

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chesnokov, Alexander; Ivanov, Oleg; Kolyadin, Vyacheslav

    2013-07-01

    A program of decommissioning of MR research reactor in the Kurchatov institute started in 2008. The decommissioning work presumed a preliminary stage, which included: removal of spent fuel from near reactor storage; removal of spent fuel assemble of metal liquid loop channel from a core; identification, sorting and disposal of radioactive objects from gateway of the reactor; identification, sorting and disposal of radioactive objects from cells of HLRW storage of the Kurchatov institute for radwaste creating form the decommissioning of MR. All these works were performed by a remote controlled means with use of a remote identification methods of highmore » radioactive objects. A distribution of activity along high radiated objects was measured by a collimated radiometer installed on the robot Brokk-90, a gamma image of the object was registered by gamma-visor. Spectrum of gamma radiation was measured by a gamma locator and semiconductor detector system. For identification of a presence of uranium isotopes in the HLRW a technique, based on the registration of characteristic radiation of U, was developed. For fragmentation of high radiated objects was used a cold cutting technique and dust suppression system was applied for reduction of volume activity of aerosols in air. The management of HLRW was performed by remote controlled robots Brokk-180 and Brokk-330. They executed sorting, cutting and parking of high radiated part of contaminated equipment. The use of these techniques allowed to reduce individual and collective doses of personal performed the decommissioning. The average individual dose of the personnel was 1,9 mSv/year in 2011, and the collective dose is estimated by 0,0605 man x Sv/year. Use of the remote control machines enables reducing the number of working personal (20 men) and doses. X-ray spectrometric methods enable determination of a presence of the U in high radiated objects and special cans and separation of them for further spent fuel inspection. The sorting of radwaste enabled shipping of the LLRW and ILRW to special repositories and keeping of the HLRW for decay in the Kurchatov institute repository. (authors)« less

  13. Application of the Finite Element Method to Reveal the Causes of Loss of Planeness of Hot-Rolled Steel Sheets during Laser Cutting

    NASA Astrophysics Data System (ADS)

    Garber, E. A.; Bolobanova, N. L.; Trusov, K. A.

    2018-01-01

    A finite element technique is developed to simulate the stresses and the strains during strip flattening to reveal the causes of the cutting-assisted loss of planeness of hot-rolled steel sheets processed in roller levelers. The loss of planeness is found to be caused by a nonuniform distribution of the flattening-induced longitudinal tensile stresses over the strip thickness and width. The application of tensile forces to a strip in a roller leveler decreases this nonuniformity and prevents loss of planeness in cutting.

  14. Lathe-cut hydrophilic contact lenses: report of 100 clinical cases.

    PubMed

    Espy, J W

    1978-10-01

    In a review of the literature, it became apparent that there were very few articles describing the advantages, as well as the fitting techniques, of lathe-cut hydrophilic contact lenses. Few practitioners, including those who fit other types of hydrophilic lenses and hard lenses, have had any experience with this lens, and considerable interest has been generated by fragmentary reports of good results. This paper describes in detail the geometry of the first lathe-cut hydrophilic lens approved by the Federal Drug Administration, the fitting methods utilizing trial lenses, and the results of 100 patients successfully fitted.

  15. Computer numeric control generation of toric surfaces

    NASA Astrophysics Data System (ADS)

    Bradley, Norman D.; Ball, Gary A.; Keller, John R.

    1994-05-01

    Until recently, the manufacture of toric ophthalmic lenses relied largely upon expensive, manual techniques for generation and polishing. Recent gains in computer numeric control (CNC) technology and tooling enable lens designers to employ single- point diamond, fly-cutting methods in the production of torics. Fly-cutting methods continue to improve, significantly expanding lens design possibilities while lowering production costs. Advantages of CNC fly cutting include precise control of surface geometry, rapid production with high throughput, and high-quality lens surface finishes requiring minimal polishing. As accessibility and affordability increase within the ophthalmic market, torics promise to dramatically expand lens design choices available to consumers.

  16. 29 CFR 530.1 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... knitting process is performed; and the manufacture of bathing suits from any purchased fabric: Provided... other finishing of knitted shirts made in the same establishment as that where the knitting process is... embroidery, thread splitting, embroidery thread cutting, scallop cutting, lace cutting, lace making-up...

  17. 29 CFR 530.1 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... knitting process is performed; and the manufacture of bathing suits from any purchased fabric: Provided... other finishing of knitted shirts made in the same establishment as that where the knitting process is... embroidery, thread splitting, embroidery thread cutting, scallop cutting, lace cutting, lace making-up...

  18. 29 CFR 530.1 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... knitting process is performed; and the manufacture of bathing suits from any purchased fabric: Provided... other finishing of knitted shirts made in the same establishment as that where the knitting process is... embroidery, thread splitting, embroidery thread cutting, scallop cutting, lace cutting, lace making-up...

  19. 29 CFR 530.1 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... knitting process is performed; and the manufacture of bathing suits from any purchased fabric: Provided... other finishing of knitted shirts made in the same establishment as that where the knitting process is... embroidery, thread splitting, embroidery thread cutting, scallop cutting, lace cutting, lace making-up...

  20. Diagnostic performance and optimal cut-off scores of the Massachusetts youth screening instrument-second version in a sample of Swiss youths in welfare and juvenile justice institutions.

    PubMed

    Dölitzsch, Claudia; Leenarts, Laura E W; Schmeck, Klaus; Fegert, Jorg M; Grisso, Thomas; Schmid, Marc

    2017-02-08

    There is a growing consensus about the importance of mental health screening of youths in welfare and juvenile justice institutions. The Massachusetts Youth Screening Instrument-second version (MAYSI-2) was specifically designed, normed and validated to assist juvenile justice facilities in the United States of America (USA), in identifying youths with potential emotional or behavioral problems. However, it is not known if the USA norm-based cut-off scores can be used in Switzerland. Therefore, the primary purpose of the current study was to estimate the diagnostic performance and optimal cut-off scores of the MAYSI-2 in a sample of Swiss youths in welfare and juvenile justice institutions. As the sample was drawn from the French-, German- and Italian-speaking parts of Switzerland, the three languages were represented in the total sample of the current study and consequently we could estimate the diagnostic performance and the optimal cut-off scores of the MAYSI-2 for the language regions separately. The other main purpose of the current study was to identify potential gender differences in the diagnostic performance and optimal cut-off scores. Participants were 297 boys and 149 girls (mean age = 16.2, SD = 2.5) recruited from 64 youth welfare and juvenile justice institutions (drawn from the French-, German- and Italian-speaking parts of Switzerland). The MAYSI-2 was used to screen for mental health or behavioral problems that could require further evaluation. Psychiatric classification was based on the Schedule for Affective Disorders and Schizophrenia for School-Age Children, Present and Lifetime version (K-SADS-PL). The MAYSI-2 scores were submitted into Receiver-Operating Characteristic (ROC) analyses to estimate the diagnostic performance and optimal 'caution' cut-off scores of the MAYSI-2. The ROC analyses revealed that nearly all homotypic mappings of MAYSI-2 scales onto (cluster of) psychiatric disorders revealed above chance level accuracy. The optimal 'caution' cut-off scores derived from the ROC curve for predicting (cluster of) psychiatric disorders were, for several MAYSI-2 scales, comparable to the USA norm-based 'caution' cut-off scores. For some MAYSI-2 scales, however, higher optimal 'caution' cut-off scores were found. With adjusted optimal 'caution' cut-off scores, the MAYSI-2 screens potential emotional or behavioral problems well in a sample of Swiss youths in welfare and juvenile justice institutions. However, as for choosing the optimal 'caution' cut off score for the MAYSI-2, both language as well as gender seems to be of importance. The results of this study point to a compelling need to test the diagnostic performance and optimal 'caution' cut-off scores of the MAYSI-2 more elaborately in larger differentiated language samples in Europe.

  1. Characterization of particulate emissions from Australian open-cut coal mines: Toward improved emission estimates.

    PubMed

    Richardson, Claire; Rutherford, Shannon; Agranovski, Igor

    2018-06-01

    Given the significance of mining as a source of particulates, accurate characterization of emissions is important for the development of appropriate emission estimation techniques for use in modeling predictions and to inform regulatory decisions. The currently available emission estimation methods for Australian open-cut coal mines relate primarily to total suspended particulates and PM 10 (particulate matter with an aerodynamic diameter <10 μm), and limited data are available relating to the PM 2.5 (<2.5 μm) size fraction. To provide an initial analysis of the appropriateness of the currently available emission estimation techniques, this paper presents results of sampling completed at three open-cut coal mines in Australia. The monitoring data demonstrate that the particulate size fraction varies for different mining activities, and that the region in which the mine is located influences the characteristics of the particulates emitted to the atmosphere. The proportion of fine particulates in the sample increased with distance from the source, with the coarse fraction being a more significant proportion of total suspended particulates close to the source of emissions. In terms of particulate composition, the results demonstrate that the particulate emissions are predominantly sourced from naturally occurring geological material, and coal comprises less than 13% of the overall emissions. The size fractionation exhibited by the sampling data sets is similar to that adopted in current Australian emission estimation methods but differs from the size fractionation presented in the U.S. Environmental Protection Agency methodology. Development of region-specific emission estimation techniques for PM 10 and PM 2.5 from open-cut coal mines is necessary to allow accurate prediction of particulate emissions to inform regulatory decisions and for use in modeling predictions. Development of region-specific emission estimation techniques for PM 10 and PM 2.5 from open-cut coal mines is necessary to allow accurate prediction of particulate emissions to inform regulatory decisions and for use in modeling predictions. Comprehensive air quality monitoring was undertaken, and corresponding recommendations were provided.

  2. In vivo Raman measurement of levofloxacin lactate in blood using a nanoparticle-coated optical fiber probe

    PubMed Central

    Liu, Shupeng; Rong, Ming; Zhang, Heng; Chen, Na; Pang, Fufei; Chen, Zhenyi; Wang, Tingyun; Yan, Jianshe

    2016-01-01

    Monitoring drug concentrations in vivo is very useful for adjusting a drug dosage during treatment and for drug research. Specifically, cutting-edge “on-line” drug research relies on knowing how drugs are metabolized or how they interact with the blood in real-time. Thus, this study explored performing in vivo Raman measurements of the model drug levofloxacin lactate in the blood using a nanoparticle-coated optical fiber probe (optical fiber nano-probe). The results show that we were able to measure real-time changes in the blood concentration of levofloxacin lactate, suggesting that this technique could be helpful for performing drug analyses and drug monitoring in a clinical setting without repeatedly withdrawing blood from patients. PMID:27231590

  3. Coordinated design of coding and modulation systems

    NASA Technical Reports Server (NTRS)

    Massey, J. L.

    1976-01-01

    Work on partial unit memory codes continued; it was shown that for a given virtual state complexity, the maximum free distance over the class of all convolutional codes is achieved within the class of unit memory codes. The effect of phase-lock loop (PLL) tracking error on coding system performance was studied by using the channel cut-off rate as the measure of quality of a modulation system. Optimum modulation signal sets for a non-white Gaussian channel considered an heuristic selection rule based on a water-filling argument. The use of error correcting codes to perform data compression by the technique of syndrome source coding was researched and a weight-and-error-locations scheme was developed that is closely related to LDSC coding.

  4. Laser-Driven Mini-Thrusters

    NASA Astrophysics Data System (ADS)

    Sterling, Enrique; Lin, Jun; Sinko, John; Kodgis, Lisa; Porter, Simon; Pakhomov, Andrew V.; Larson, C. William; Mead, Franklin B.

    2006-05-01

    Laser-driven mini-thrusters were studied using Delrin® and PVC (Delrin® is a registered trademark of DuPont) as propellants. TEA CO2 laser (λ = 10.6 μm) was used as a driving laser. Coupling coefficients were deduced from two independent techniques: force-time curves measured with a piezoelectric sensor and ballistic pendulum. Time-resolved ICCD images of the expanding plasma and combustion products were analyzed in order to determine the main process that generates the thrust. The measurements were also performed in a nitrogen atmosphere in order to test the combustion effects on thrust. A pinhole transmission experiment was performed for the study of the cut-off time when the ablation/air breakdown plasma becomes opaque to the incoming laser pulse.

  5. Genetic relationships between carcass cut weights predicted from video image analysis and other performance traits in cattle.

    PubMed

    Pabiou, T; Fikse, W F; Amer, P R; Cromie, A R; Näsholm, A; Berry, D P

    2012-09-01

    The objective of this study was to quantify the genetic associations between a range of carcass-related traits including wholesale cut weights predicted from video image analysis (VIA) technology, and a range of pre-slaughter performance traits in commercial Irish cattle. Predicted carcass cut weights comprised of cut weights based on retail value: lower value cuts (LVC), medium value cuts (MVC), high value cuts (HVC) and very high value cuts (VHVC), as well as total meat, fat and bone weights. Four main sources of data were used in the genetic analyses: price data of live animals collected from livestock auctions, live-weight data and linear type collected from both commercial and pedigree farms as well as from livestock auctions and weanling quality recorded on-farm. Heritability of carcass cut weights ranged from 0.21 to 0.39. Genetic correlations between the cut traits and the other performance traits were estimated using a series of bivariate sire linear mixed models where carcass cut weights were phenotypically adjusted to a constant carcass weight. Strongest positive genetic correlations were obtained between predicted carcass cut weights and carcass value (min r g(MVC) = 0.35; max r(g(VHVC)) = 0.69), and animal price at both weaning (min r(g(MVC)) = 0.37; max r(g(VHVC)) = 0.66) and post weaning (min r(g(MVC)) = 0.50; max r(g(VHVC)) = 0.67). Moderate genetic correlations were obtained between carcass cut weights and calf price (min r g(HVC) = 0.34; max r g(LVC) = 0.45), weanling quality (min r(g(MVC)) = 0.12; max r (g(VHVC)) = 0.49), linear scores for muscularity at both weaning (hindquarter development: min r(g(MVC)) = -0.06; max r(g(VHVC)) = 0.46), post weaning (hindquarter development: min r(g(MVC)) = 0.23; max r(g(VHVC)) = 0.44). The genetic correlations between total meat weight were consistent with those observed with the predicted wholesale cut weights. Total fat and total bone weights were generally negatively correlated with carcass value, auction prices and weanling quality. Total bone weight was, however, positively correlated with skeletal scores at weaning and post weaning. These results indicate that some traits collected early in life are moderate-to-strongly correlated with carcass cut weights predicted from VIA technology. This information can be used to improve the accuracy of selection for carcass cut weights in national genetic evaluations.

  6. Piezosurgery as a further technical adjunct in minimally invasive supraorbital keyhole approach and lateral orbitotomy.

    PubMed

    Iacoangeli, Maurizio; Di Rienzo, Alessandro; Nocchi, Niccolo; Balercia, Paolo; Lupi, Ettore; Regnicolo, Luana; Di Somma, Lucia Giovanna Maria; Alvaro, Lorenzo; Scerrati, Massimo

    2015-03-01

    One of the problems in neurosurgery is how to perform rapid and effective craniotomies that minimize the risk of injury to underlying eloquent structures. The traditional high-powered pneumatic tools and saws are efficient in terms of speed and penetration, but they can provoke bone necrosis and sometimes damage neurovascular structures. As an alternative, we evaluated the piezoelectric bone scalpel (piezosurgery), a device that potentially allows thinner and more precise bone cutting without lesioning neighboring delicate structures, even in the case of accidental contact. From January 2009 to December 2011, 20 patients (8 men and 12 women), 19 to 72 years of age (mean: 49.3 years) were treated using piezosurgery. Surgery was performed for the removal of anterior cranial fossa meningiomas, orbital tumors, and sinonasal lesions with intracranial extension. The time required to perform craniotomy using piezosurgery is a few minutes longer than with traditional drills. No damage was observed using the piezoelectric device. Follow-up clinical and neuroradiologic evaluation showed a faster and better ossification of the bone flap with good esthetic results. Piezosurgery is a new promising technique for selective bone cutting with soft tissue preservation. This instrument seems suitable to perform precise thin osteotomies while limiting damage to the bone itself and to the underlying delicate structures even in the case of unintentional contact. These advantages make the piezoelectric bone scalpel a particularly attractive instrument in neurosurgery. Georg Thieme Verlag KG Stuttgart · New York.

  7. Application of rotational atherectomy in the drug-eluting stent era

    PubMed Central

    Chen, Chun-Chi; Hsieh, I-Chang

    2013-01-01

    Rotational atherectomy (RA) was introduced in the interventional arena in 1988 as a dedicated device for calcified lesions. Due to the complexity of the technique, the development of alternative methods such as the cutting balloon procedure, and the high restenosis rate of subsequent bare metal stenting in long lesions, its use had later declined. However, with the increasing use of drug-eluting stents (DES) and the aggressive treatment of longer lesions, the number of procedure performed with RA has increased significantly again in recent years. In this article, we reviewed the application of RA in DES era. PMID:24133506

  8. Two multidimensional chromatographic methods for enantiomeric analysis of o,p'-DDT and o,p'-DDD in contaminated soil and air in a malaria area of South Africa.

    PubMed

    Naudé, Yvette; Rohwer, Egmont R

    2012-06-12

    In rural parts of South Africa the organochlorine insecticide DDT (1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane) is still used for malaria vector control where traditional dwellings are sprayed on the inside with small quantities of technical DDT. Since o,p'-DDT may show enantioselective oestrogenicity and biodegradability, it is important to analyse enantiomers of o,p'-DDT and its chiral degradation product, o,p'-DDD, for both health and environmental-forensic considerations. Generally, chiral analysis is performed using heart-cut multidimensional gas chromatography (MDGC) and, more recently, comprehensive two-dimensional gas chromatography (GC×GC). We developed an off-line gas chromatographic fraction collection (heart-cut) procedure for the selective capturing of the appropriate isomers from a first apolar column, followed by reinjection and separation on a second chiral column. Only the o,p'-isomers of DDT and DDD fractions from the first dimension complex chromatogram (achiral apolar GC column separation) were selectively collected onto a polydimethylsiloxane (PDMS) multichannel open tubular silicone rubber trap by simply placing the latter device on the flame tip of an inactivated flame ionisation detector (FID). The multichannel trap containing the o,p'-heart-cuts was then thermally desorbed into a GC with time-of-flight mass spectrometry detection (GC-TOFMS) for second dimension enantioselective separation on a chiral column (β-cyclodextrin-based). By selectively capturing only the o,p'-isomers from the complex sample chromatogram, (1)D separation of ultra-trace level enantiomers could be achieved on the second chiral column without matrix interference. Here, we present solventless concentration techniques for extraction of DDT from contaminated soil and air, and report enantiomeric fraction (EF) values of o,p'-DDT and o,p'-DDD obtained by a new multidimensional approach for heart-cut gas chromatographic fraction collection for off-line second dimension enantiomeric separation by (1)D GC-TOFMS of selected isomers. This multidimensional method is compared to the complementary technique of comprehensive GC×GC-TOFMS using the same enantioselective column, this time as the first dimension of separation. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Enlarging the operation range of a centrifugal compressor by cutting vanes based on CFD

    NASA Astrophysics Data System (ADS)

    Mo, J. T.; Gu, C. H.; Pan, X. H.; Y Zheng, S.

    2013-12-01

    Many centrifugal compressors are liable to insufficient operation range. The purpose of this paper is to enlarge the operation range of a centrifugal compressor used in turbocharger by cutting vanes. Some numerical works have been done based on CFD. The comparison of the calculated and measured results shows good agreement. The overall performance characteristics of the centrifugal compressor with different cutted vanes are observed and analyzed. The performance characteristic curves show that cutting vanes can increase the operation range by more than 50% with the loss of the highest efficiency limited in 1%. The flow fields are also shown in this paper and related explanations about the change of the performance characteristics curves are given. Shock wave is also detected in the simulation, and some related characteristics are summed up.

  10. Combining the Cutting and Mulliken methods for primary repair of the bilateral cleft lip nose.

    PubMed

    Morovic, Carmen Gloria; Cutting, Court

    2005-11-01

    Since 1990, primary bilateral cleft nasal reconstruction has been focused on placing the lower lateral cartilages into normal anatomical position. Of the four major techniques in this class, the Cutting (i.e., retrograde) method and the Mulliken method have been most successful. The retrograde method makes no external nasal incisions, but requires either preoperative or postoperative nasal molding to achieve maximum benefit. Mulliken's technique does not require molding, but leaves the footplates of the medial crura in the depression above the projecting premaxilla associated with the diminutive anterior nasal spine. Leaving the footplates in place also prevents adequate approximation of the alar bases. In this article, the two methods are combined to achieve the benefits of both. We report our experience with the retrograde nasal approach associated with marginal rim incisions (Mulliken method) in a series of 25 consecutive bilateral cleft lip cases simultaneous with lip repair. We performed a retrograde approach through membranous septum incisions elevating a prolabial-columellar flap. To facilitate alar cartilage manipulation we added bilateral marginal rim incisions. Nasal width, columella length and width, tip projection, and nasolabial angle were analyzed after a minimum of 2 years after surgery. These were compared with a normal, age-matched, control group. We also examined nostril symmetry and marginal nostril scars. Columellar length was not statistically significantly different from that of the control group (p = 0.122442). Nasal width, columellar width, tip projection, and nasolabial angle were all significantly greater in the cleft group than normal (p < 0.001). No hypertrophied scars were found associated with the marginal rim scar. Adding the Mulliken approach allows alar cartilage manipulation to be performed more easily than when using the retrograde approach alone. Tip projection and alar base narrowing are facilitated using the combined technique rather than the Mulliken approach alone. Prolabial flap manipulation is safe using this combined approach, even in cases with a severely projected premaxilla. We believe that the combined approach is safe and yields better long-term results than either technique alone.

  11. Gender Differences among Sagittal Plane Knee Kinematic and Ground Reaction Force Characteristics during a Rapid Sprint and Cut Maneuver

    ERIC Educational Resources Information Center

    James, C. Roger; Sizer, Phillip S.; Starch, David W.; Lockhart, Thurmon E.; Slauterbeck, James

    2004-01-01

    Women are more prone to anterior cruciate ligament (ACL) injury during cutting sports than men. The purpose of this study was to examine knee kinematic and ground reaction forces (GRF) differences between genders during cutting. Male and female athletes performed cutting trials while force platform and video data were recorded (180 Hz).…

  12. Sharper angle, higher risk? The effect of cutting angle on knee mechanics in invasion sport athletes.

    PubMed

    Schreurs, Mervin J; Benjaminse, Anne; Lemmink, Koen A P M

    2017-10-03

    Cutting is an important skill in team-sports, but unfortunately is also related to non-contact ACL injuries. The purpose was to examine knee kinetics and kinematics at different cutting angles. 13 males and 16 females performed cuts at different angles (45°, 90°, 135° and 180°) at maximum speed. 3D kinematics and kinetics were collected. To determine differences across cutting angles (45°, 90°, 135° and 180°) and sex (female, male), a 4×2 repeated measures ANOVA was conducted followed by post hoc comparisons (Bonferroni) with alpha level set at α≤0.05a priori. At all cutting angles, males showed greater knee flexion angles than females (p<0.01). Also, where males performed all cutting angles with no differences in the amount of knee flexion -42.53°±8.95°, females decreased their knee flexion angle from -40.6°±7.2° when cutting at 45° to -36.81°±9.10° when cutting at 90°, 135° and 180° (p<0.01). Knee flexion moment decreased for both sexes when cutting towards sharper angles (p<0.05). At 90°, 135° and 180°, males showed greater knee valgus moments than females. For both sexes, knee valgus moment increased towards the sharper cutting angles and then stabilized compared to the 45° cutting angle (p<0.01). Both females and males showed smaller vGRF when cutting to sharper angles (p<0.01). It can be concluded that different cutting angles demand different knee kinematics and kinetics. Sharper cutting angles place the knee more at risk. However, females and males handle this differently, which has implications for injury prevention. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Biomechanical Analysis of Defensive Cutting Actions During Game Situations: Six Cases in Collegiate Soccer Competitions

    PubMed Central

    Sasaki, Shogo; Koga, Hideyuki; Krosshaug, Tron; Kaneko, Satoshi; Fukubayashi, Toru

    2015-01-01

    The strengths of interpersonal dyads formed by the attacker and defender in one-on-one situations are crucial for performance in team ball sports such as soccer. The purpose of this study was to analyze the kinematics of one-on-one defensive movements in soccer competitions, and determine the relationships between lower limb kinematics and the center of mass translation during cutting actions. Six defensive scenes in which a player was responding to an offender’s dribble attack were selected for analysis. To reconstruct the three-dimensional kinematics of the players, we used a photogrammetric model-based image-matching technique. The hip and knee kinematics were calculated from the matched skeleton model. In addition, the center of mass height was expressed as a ratio of each participant’s body height. The relationships between the center of mass height and the kinematics were determined by the Pearson’s product-moment correlation coefficient. The normalized center of mass height at initial contact was correlated with the vertical center of mass displacement (r = 0.832, p = 0.040) and hip flexion angle at initial contact (r = −0.823, p = 0.044). This suggests that the lower center of mass at initial contact is an important factor to reduce the downwards vertical center of mass translation during defensive cutting actions, and that this is executed primarily through hip flexion. It is therefore recommended that players land with an adequately flexed hip at initial contact during one-on-one cutting actions to minimize the vertical center of mass excursion. PMID:26240644

  14. Recent Advances in Bioprinting and Applications for Biosensing

    PubMed Central

    Dias, Andrew D.; Kingsley, David M.; Corr, David T.

    2014-01-01

    Future biosensing applications will require high performance, including real-time monitoring of physiological events, incorporation of biosensors into feedback-based devices, detection of toxins, and advanced diagnostics. Such functionality will necessitate biosensors with increased sensitivity, specificity, and throughput, as well as the ability to simultaneously detect multiple analytes. While these demands have yet to be fully realized, recent advances in biofabrication may allow sensors to achieve the high spatial sensitivity required, and bring us closer to achieving devices with these capabilities. To this end, we review recent advances in biofabrication techniques that may enable cutting-edge biosensors. In particular, we focus on bioprinting techniques (e.g., microcontact printing, inkjet printing, and laser direct-write) that may prove pivotal to biosensor fabrication and scaling. Recent biosensors have employed these fabrication techniques with success, and further development may enable higher performance, including multiplexing multiple analytes or cell types within a single biosensor. We also review recent advances in 3D bioprinting, and explore their potential to create biosensors with live cells encapsulated in 3D microenvironments. Such advances in biofabrication will expand biosensor utility and availability, with impact realized in many interdisciplinary fields, as well as in the clinic. PMID:25587413

  15. Very High Reflectivity Supermirrors And Their Applications

    NASA Astrophysics Data System (ADS)

    Mezei, F.

    1989-01-01

    Very high reflectivity (some 95 % or better) supermirrors, with cut-off angles up to 2 times the critical angle of Ni coated simple total reflection neutron mirrors, can be produced using well established conventional deposition techniques. This performance makes applications involving multiple reflections and transmission geometries feasible, which in turn allow us to use more sophisticated neutron optical systems in order to optimize performance and minimize the amount a scarce supermirrors required. A key feature of several of these novel systems is the distribution of tasks between the several optical components achieving the desired performance by multiple action. The design and characteristics of a series of novel applications, such as polarizing cavities, collimators and guides, non-polarizing guides, beam compressors, deflectors and splitters (most of them tested or being implemented) are the main subjects of the present paper.

  16. Hybrid approach for robust diagnostics of cutting tools

    NASA Astrophysics Data System (ADS)

    Ramamurthi, K.; Hough, C. L., Jr.

    1994-03-01

    A new multisensor based hybrid technique has been developed for robust diagnosis of cutting tools. The technique combines the concepts of pattern classification and real-time knowledge based systems (RTKBS) and draws upon their strengths; learning facility in the case of pattern classification and a higher level of reasoning in the case of RTKBS. It eliminates some of their major drawbacks: false alarms or delayed/lack of diagnosis in case of pattern classification and tedious knowledge base generation in case of RTKBS. It utilizes a dynamic distance classifier, developed upon a new separability criterion and a new definition of robust diagnosis for achieving these benefits. The promise of this technique has been proven concretely through an on-line diagnosis of drill wear. Its suitability for practical implementation is substantiated by the use of practical, inexpensive, machine-mounted sensors and low-cost delivery systems.

  17. Surgical ablation for atrial fibrillation for two decades: are the results of new techniques equivalent to the Cox maze III procedure?

    PubMed

    Stulak, John M; Suri, Rakesh M; Burkhart, Harold M; Daly, Richard C; Dearani, Joseph A; Greason, Kevin L; Joyce, Lyle D; Park, Soon J; Schaff, Hartzell V

    2014-05-01

    A significant evolution has occurred in surgical ablation for atrial fibrillation (AF) toward alternate energy sources, lesion sets, and approaches, with the intent of simplifying the Cox maze III operation and maintaining similar outcomes. Because no large comparative studies with long-term follow-up exist, we have reviewed our experience. From January 1993 to January 2011, 1540 patients underwent surgical ablation for AF. The operations were performed in conjunction with repair of congenital heart disease in 351 (30%) and adult-acquired disease in 1189 patients (70%). In the 1189 patients, preoperative AF was paroxysmal in 598 (50%) and persistent in 591 (50%). The energy sources included cut and sew in 521 (44%), cryothermy in 267 (22%), radiofrequency in 262 (22%), and a combination in 139 patients (12%). The lesion sets included biatrial in 810 (68%), isolated pulmonary vein isolation in 269 (23%), and isolated left atrial in 110 (9%). AF ablation was performed during isolated mitral valve surgery in 516 patients (43%). The median follow-up was 33 months (maximum, 20.3 years), and late rhythm follow-up was available for 80%. The cut and sew Cox maze III procedure was superior at each follow-up interval (P = .01, P = .03, and P < .001). On multivariate analysis, the cut and sew maze procedure was independently associated with less risk of recurrent AF at a follow-up period of 1 to 5 years (hazard ratio, 0.4; 95% confidence interval, 0.24-0.69; P < .001) and >5 years (hazard ratio, 0.23; 95% confidence interval, 0.12-0.42; P < .001) for all patients. When performed during isolated mitral valve surgery, the cut and sew Cox maze III was also independently associated with less risk of recurrent AF at >5 years (hazard ratio, 0.23; 95% confidence interval, 0.08-0.66; P = .007). The cut and sew Cox maze III procedure appears to offer significantly greater freedom from AF without antiarrhythmic medications compared with alternate energy sources and lesion sets. Although alternate energy sources offer the advantage of quicker application and the possibility of minimally invasive applications, the Cox maze III operation arguably remains the reference standard for the surgical treatment of AF and should still be considered, especially for patients for whom AF ablation is of critical importance. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  18. Experimental analysis of Nd-YAG laser cutting of sheet materials - A review

    NASA Astrophysics Data System (ADS)

    Sharma, Amit; Yadava, Vinod

    2018-01-01

    Cutting of sheet material is considered as an important process due to its relevance among products of everyday life such as aircrafts, ships, cars, furniture etc. Among various sheet cutting processes (ASCPs), laser beam cutting is one of the most capable ASCP to create complex geometries with stringent design requirements in difficult-to-cut sheet materials. Based on the recent research work in the area of sheet cutting, it is found that the Nd-YAG laser is used for cutting of sheet material in general and reflective sheet material in particular. This paper reviews the experimental analysis of Nd-YAG laser cutting process, carried out to study the influence of laser cutting parameters on the process performance index. The significance of experimental modeling and different optimization approaches employed by various researchers has also been discussed in this study.

  19. An adaptive simplex cut-cell method for high-order discontinuous Galerkin discretizations of elliptic interface problems and conjugate heat transfer problems

    NASA Astrophysics Data System (ADS)

    Sun, Huafei; Darmofal, David L.

    2014-12-01

    In this paper we propose a new high-order solution framework for interface problems on non-interface-conforming meshes. The framework consists of a discontinuous Galerkin (DG) discretization, a simplex cut-cell technique, and an output-based adaptive scheme. We first present a DG discretization with a dual-consistent output evaluation for elliptic interface problems on interface-conforming meshes, and then extend the method to handle multi-physics interface problems, in particular conjugate heat transfer (CHT) problems. The method is then applied to non-interface-conforming meshes using a cut-cell technique, where the interface definition is completely separate from the mesh generation process. No assumption is made on the interface shape (other than Lipschitz continuity). We then equip our strategy with an output-based adaptive scheme for an accurate output prediction. Through numerical examples, we demonstrate high-order convergence for elliptic interface problems and CHT problems with both smooth and non-smooth interface shapes.

  20. Width of thermal damage after using the YAG contact laser for cutting biological tissue: animal experimental investigation.

    PubMed

    Mecke, H; Schünke, M; Schnaidt, S; Freys, I; Semm, K

    1991-01-01

    At the University Women's Clinic in Kiel, the YAG contact laser has been used as a cutting instrument in pelviscopic operations since 1987. When the laser cuts, it produces only a scant amount of mechanical trauma. The determining factor is the amount of thermal damage produced along the wound margins and in direct neighboring tissue. The extent of the tissue change seen in the uterus and liver parenchyma of rats and the striated muscle of rabbits after application of the YAG contact laser was demonstrated using various staining techniques and stains. Liver parenchyma proved to be the most sensitive to thermal damage. In the uterine horn, enzyme-histochemical ATPase and alkaline phosphatase demonstrations showed a significantly wider zone of thermal damage after laser incision than did hematoxylin-eosin and Goldner staining techniques. A good understanding of the extent of thermal damage is essential for atraumatic pelviscopic operations using the YAG contact laser and also for the preventing of complications.

  1. Endoscopic-assisted resection of peripheral osteoma using piezosurgery.

    PubMed

    Ochiai, Shigeki; Kuroyanagi, Norio; Sakuma, Hidenori; Sakuma, Hidenobu; Miyachi, Hitoshi; Shimozato, Kazuo

    2013-01-01

    Endoscopic-assisted surgery has gained widespread popularity as a minimally invasive procedure, particularly in the field of maxillofacial surgery. Because the surgical field around the mandibular angle is extremely narrow, the surrounding tissues may get caught in sharp rotary cutting instruments. In piezosurgery, bone tissues are selectively cut. This technique has various applications because minimal damage is caused by the rotary cutting instruments when they briefly come in contact with soft tissues. We report the case of a 33-year-old man who underwent resection of an osteoma in the region of the mandibular angle region via an intraoral approach. During surgery, the complete surgical field was within the view of the endoscope, thereby enabling the surgeon to easily resection the osteoma with the piezosurgery device. Considering that piezosurgery limits the extent of surgical invasion, this is an excellent low-risk technique that can be used in the field of maxillofacial surgery. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Laser cutting of ultra-thin glasses based on a nonlinear laser interaction effect

    NASA Astrophysics Data System (ADS)

    Chen, Jian; Wu, Zhouling

    2013-07-01

    Glass panel substrates have been widely used in consumer electronics such as in flat panel TVs, laptops, and cell phones. With the advancement in the industry, the glass substrates are becoming thinner and stronger for reduced weight and volume, which brings great challenges for traditional mechanical processes in terms of cut quality, yield, and throughput. Laser glass cutting provides a non-contact process with minimum impact and superior quality compared to the mechanical counterparts. In this paper, we presented recent progresses in advanced laser processing of ultra-thin glass substrates, especially laser-cutting of ultra-thin glasses by a high power laser through a nonlinear interaction effect. Our results indicate that this technique has great potential of application for mass production of ultra-thin glass substrates.

  3. Experimental analysis on semi-finishing machining of Ti6Al4V additively manufactured by direct melting laser sintering

    NASA Astrophysics Data System (ADS)

    Imbrogno, Stano; Bordin, Alberto; Bruschi, Stefania; Umbrello, Domenico

    2016-10-01

    The Additive Manufacturing (AM) techniques are particularly appealing especially for titanium aerospace and biomedical components because they permit to achieve a strong reduction of the buy-to-fly ratio. However, finishing machining operations are often necessary to reduce the uneven surface roughness and geometrics because of local missing accuracy. This work shows the influence of the cutting parameters, cutting speed and feed rate, on the cutting forces as well as on the thermal field observed in the cutting zone, during a turning operation carried out on bars made of Ti6Al4V obtained by the AM process called Direct Metal Laser Sintering (DMLS). Moreover, the sub-surface microstructure alterations due to the process are also showed and commented.

  4. The optimization study on the tool wear of carbide cutting tool during milling Carbon Fibre Reinforced (CFRP) using Response Surface Methodology (RSM)

    NASA Astrophysics Data System (ADS)

    Nor Khairusshima, M. K.; Hafiz Zakwan, B. Muhammad; Suhaily, M.; Sharifah, I. S. S.; Shaffiar, N. M.; Rashid, M. A. N.

    2018-01-01

    Carbon Fibre Reinforced Plastic (CFRP) composite has become one of famous materials in industry, such as automotive, aeronautics, aerospace and aircraft. CFRP is attractive due to its properties, which promising better strength and high specification of mechanical properties other than its high resistance to corrosion. Other than being abrasive material due to the carbon nature, CFRP is an anisotropic material, which the knowledge of machining metal and steel cannot be applied during machining CFRP. The improper technique and parameters used to machine CFRP may result in high tool wear. This paper is to study the tool wear of 8 mm diameter carbide cutting tool during milling CFRP. To predict the suitable cutting parameters within range of 3500-6220 (rev/min), 200-245 (mm/min), and 0.4-1.8 (mm) for cutting speed, speed, feed rate and depth of cut respectively, which produce optimized result (less tool wear), Response Surface Methodology (RSM) has been used. Based on the developed mathematical model, feed rate was identified as the primary significant item that influenced tool wear. The optimized cutting parameters are cutting speed, feed and depth of cut of 3500 rev/min, 200 mm/min and 0.5 mm, respectively, with tool wear of 0.0267 mm. It is also can be observed that as the cutting speed and feed rate increased the tool wear is increasing.

  5. Root dentine and endodontic instrumentation: cutting edge microscopic imaging

    PubMed Central

    2016-01-01

    Cutting of the dental hard tissues is an integral part of restorative dentistry. Cutting of the root dentine is also needed in preparation prior to endodontic treatment, with significant commercial investment for the development of flexible cutting instruments based around nickel titanium (NiTi) alloys. This paper describes the evolution of endodontic cutting instruments, both in materials used, e.g. the transition from stainless steel to NiTi, and the design of the actual instruments themselves and their method of activation—by hand or motor driven. We have been examining tooth-cutting interactions microscopically for over 25 years using a variety of microscopic techniques; in particular, video-rate confocal microscopy. This has given a unique insight into how many of the procedures that we take for granted are achieved in clinical practice, by showing microscopic video images of the cutting as it occurs within the tooth. This technology has now been extended to allow imaging of the endodontic instrument and the root canal wall for the first time. We are able to image dentine distortion and crack propagation during endodontic filing of the root canal space. We are also able to visualize the often claimed, but seldom seen action of contemporary endodontic instruments. PMID:27274802

  6. Root dentine and endodontic instrumentation: cutting edge microscopic imaging.

    PubMed

    Atmeh, Amre R; Watson, Timothy F

    2016-06-06

    Cutting of the dental hard tissues is an integral part of restorative dentistry. Cutting of the root dentine is also needed in preparation prior to endodontic treatment, with significant commercial investment for the development of flexible cutting instruments based around nickel titanium (NiTi) alloys. This paper describes the evolution of endodontic cutting instruments, both in materials used, e.g. the transition from stainless steel to NiTi, and the design of the actual instruments themselves and their method of activation-by hand or motor driven. We have been examining tooth-cutting interactions microscopically for over 25 years using a variety of microscopic techniques; in particular, video-rate confocal microscopy. This has given a unique insight into how many of the procedures that we take for granted are achieved in clinical practice, by showing microscopic video images of the cutting as it occurs within the tooth. This technology has now been extended to allow imaging of the endodontic instrument and the root canal wall for the first time. We are able to image dentine distortion and crack propagation during endodontic filing of the root canal space. We are also able to visualize the often claimed, but seldom seen action of contemporary endodontic instruments.

  7. Effect of cutting fluids and cutting conditions on surface integrity and tool wear in turning of Inconel 713C

    NASA Astrophysics Data System (ADS)

    Hikiji, R.

    2018-01-01

    The trend toward downsizing of engines helps to increase the number of turbochargers around Europe. As for the turbocharger, the temperature of the exhaust gas is so high that the parts made of nickel base super alloy Inconel 713C are used as high temperature strength metals. External turning of Inconel 713C which is used as the actual automotive parts was carried out. The effect of the cutting fluids and cutting conditions on the surface integrity and tool wear was investigated, considering global environment and cost performance. As a result, in the range of the cutting conditions used this time, when the depth of cut was small, the good surface integrity and tool life were obtained. However, in the case of the large corner radius, it was found that the more the cutting length increased, the more the tool wear increased. When the cutting length is so large, the surface integrity and tool life got worse. As for the cutting fluids, it was found that the synthetic type showed better performance in the surface integrity and tool life than the conventional emulsion. However, it was clear that the large corner radius made the surface roughness and tool life good, but it affected the size error etc. in machining the workpiece held in a cantilever style.

  8. Sidestep and crossover lower limb kinematics during a prolonged sport-like agility test.

    PubMed

    Potter, Danielle; Reidinger, Kellie; Szymialowicz, Rebecca; Martin, Thomas; Dione, Donald; Feinn, Richard; Wallace, David; Garbalosa, Juan C

    2014-10-01

    Non-contact anterior cruciate ligament (ACL) injuries in athletes occur more often towards the end of athletic competitions. However, the exact mechanisms of how prolonged activity increases the risk for ACL injuries are not clear. To determine the effect of prolonged activity on the hip and knee kinematics observed during self-selected cutting maneuvers performed in a timed agility test. Nineteen female Division I collegiate soccer players completed a self-selected cutting agility test until they were unable to meet a set performance time (one standard deviation of the average baseline trial). Using the 3D dimensional coordinate data the cut type was identified by the principle investigators. The 3D hip and knee angles at 32ms post heel strike were analyzed using a two-factor, linear mixed model to assess the effect of prolonged activity and cut type on the recorded mean hip and knee angles. Athletes performed either sidestep or crossover cuts. An effect of cut type and prolonged activity was seen at the hip and knee. During the prolonged activity trials, the knee was relatively more adducted and both the hip and knee were less flexed than during the baseline trials regardless of cut type. Regardless of activity status, during sidestep cuts, the hip was more internally rotated and abducted, and less flexed than during crossover cuts while the knee was more abducted and less flexed during the sidestep than crossover cuts. During a sport-like agility test, prolonged activity appears to predispose the athlete to position their knee in a more extended and abducted posture and their hip in a more extended posture. This position has been suggested to place stress on the ACL and potentially increase the risk for injury. Clinicians may want to consider the effects of prolonged activity on biomechanical risk factors for sustaining ACL injuries in the design of intervention strategies to prevent ACL injuries. Level 4.

  9. Teaching learning algorithm based optimization of kerf deviations in pulsed Nd:YAG laser cutting of Kevlar-29 composite laminates

    NASA Astrophysics Data System (ADS)

    Gautam, Girish Dutt; Pandey, Arun Kumar

    2018-03-01

    Kevlar is the most popular aramid fiber and most commonly used in different technologically advanced industries for various applications. But the precise cutting of Kevlar composite laminates is a difficult task. The conventional cutting methods face various defects such as delamination, burr formation, fiber pullout with poor surface quality and their mechanical performance is greatly affected by these defects. The laser beam machining may be an alternative of the conventional cutting processes due to its non-contact nature, requirement of low specific energy with higher production rate. But this process also faces some problems that may be minimized by operating the machine at optimum parameters levels. This research paper examines the effective utilization of the Nd:YAG laser cutting system on difficult-to-cut Kevlar-29 composite laminates. The objective of the proposed work is to find the optimum process parameters settings for getting the minimum kerf deviations at both sides. The experiments have been conducted on Kevlar-29 composite laminates having thickness 1.25 mm by using Box-Benkhen design with two center points. The experimental data have been used for the optimization by using the proposed methodology. For the optimization, Teaching learning Algorithm based approach has been employed to obtain the minimum kerf deviation at bottom and top sides. A self coded Matlab program has been developed by using the proposed methodology and this program has been used for the optimization. Finally, the confirmation tests have been performed to compare the experimental and optimum results obtained by the proposed methodology. The comparison results show that the machining performance in the laser beam cutting process has been remarkably improved through proposed approach. Finally, the influence of different laser cutting parameters such as lamp current, pulse frequency, pulse width, compressed air pressure and cutting speed on top kerf deviation and bottom kerf deviation during the Nd:YAG laser cutting of Kevlar-29 laminates have been discussed.

  10. High power laser downhole cutting tools and systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zediker, Mark S; Rinzler, Charles C; Faircloth, Brian O

    Downhole cutting systems, devices and methods for utilizing 10 kW or more laser energy transmitted deep into the earth with the suppression of associated nonlinear phenomena. Systems and devices for the laser cutting operations within a borehole in the earth. These systems and devices can deliver high power laser energy down a deep borehole, while maintaining the high power to perform cutting operations in such boreholes deep within the earth.

  11. Experimental investigation of transient temperature characteristic in high power fiber laser cutting of a thick steel plate

    NASA Astrophysics Data System (ADS)

    Phi Long, Nguyen; Matsunaga, Yukihiro; Hanari, Toshihide; Yamada, Tomonori; Muramatsu, Toshiharu

    2016-10-01

    Experiment of temperature measurement was performed to investigate the transient temperature characteristics of molten metal during laser cutting. The aim of this study was to establish a method for measuring the surface temperature variation near the molten pool correlated with changes in cutting parameters. The relationship between temperature inside the kerf cut and characteristic of the cut surface was investigated by using thermography and thermocouples. Results show strong correlations between the transient temperatures and the thermal image for different cutting conditions. In addition, two-color thermometer has been used to obtain radiation intensity emitted from the irradiating zone as a function of operating conditions. Experiments have shown that one can detect the cutting quality by characterization of the surface temperature during laser cutting process.

  12. Decision-Making Influences Tibial Impact Accelerations During Lateral Cutting.

    PubMed

    Lucas, Logan A; England, Benjamin S; Mason, Travis W; Lanning, Christopher R; Miller, Taylor M; Morgan, Alexander M; Almonroeder, Thomas G

    2018-05-29

    Lower extremity musculoskeletal injuries are common in sports such as basketball and soccer. Athletes competing in sports of this nature must maneuver in response to the actions of their teammates, opponents, etc. This limits their ability to pre-plan movements. The purpose of this study was to compare impact accelerations during pre-planned vs. un-planned lateral cutting. Thirty subjects (15 males, 15 females) performed pre-planned and un-planned cuts while we analyzed impact accelerations using an accelerometer secured to their tibia. For the pre-planned condition, subjects were aware of the movement to perform before initiating a trial. For the un-planned condition, subjects initiated their movement and then reacted to the illumination of one of three visual stimuli which dictated whether they would cut, land, or land-and-jump. A mixed-model ANOVA with a between factor of sex (male, female) and a within factor of condition (pre-planned, un-planned) was used to analyze the magnitude and variability of the impact accelerations for the cutting trials. Both males and females demonstrated higher impact accelerations (p = .010) and a trend toward greater inter-trial variability (p = .073) for the un-planned cutting trials (vs. pre-planned cuts). Un-planned cutting may place greater demands on the musculoskeletal system.

  13. Analysis of the convergence rules of full-range PSD surface error of magnetorheological figuring KDP crystal.

    PubMed

    Chen, Shaoshan; He, Deyu; Wu, Yi; Chen, Huangfei; Zhang, Zaijing; Chen, Yunlei

    2016-10-01

    A new non-aqueous and abrasive-free magnetorheological finishing (MRF) method is adopted for processing potassium dihydrogen phosphate (KDP) crystal due to its low hardness, high brittleness, temperature sensitivity, and water solubility. This paper researches the convergence rules of the surface error of an initial single-point diamond turning (SPDT)-finished KDP crystal after MRF polishing. Currently, the SPDT process contains spiral cutting and fly cutting. The main difference of these two processes lies in the morphology of intermediate-frequency turning marks on the surface, which affects the convergence rules. The turning marks after spiral cutting are a series of concentric circles, while the turning marks after fly cutting are a series of parallel big arcs. Polishing results indicate that MRF polishing can only improve the low-frequency errors (L>10  mm) of a spiral-cutting KDP crystal. MRF polishing can improve the full-range surface errors (L>0.01  mm) of a fly-cutting KDP crystal if the polishing process is not done more than two times for single surface. We can conclude a fly-cutting KDP crystal will meet better optical performance after MRF figuring than a spiral-cutting KDP crystal with similar initial surface performance.

  14. Properties and Cutting Performance of TiAlSiN Coating Prepared by Cathode Arc Ion Plating

    NASA Astrophysics Data System (ADS)

    Zhang, Er-Geng; Chen, Qiang; Wang, Qin-Xue; Huang, Biao

    2016-06-01

    TiAlSiN coating was deposited on high-speed steel (HSS) samples and cemented carbide tool inserts, respectively, by a new coating preparation procedure, and its properties and cutting performance were characterized. The coating thickness, chemical composition, microstructure morphology and mechanical properties were investigated by X-ray fluorescence measurement system, energy dispersive spectrometer (EDS), scanning electron microscope (SEM), nanoindentation, Rockwell hardness tester and ball-on-disc tribometer. A 3D orthogonal cutting experiment model was established by DEFORM-3D to study the influences of different coating thicknesses on cutting force and temperature, and the field cutting experiment was carried out. The results show that the thickness of TiAlSiN coating is 3.14μm prepared by the 3μm preparation procedure, microhardness is 36.727GPa with the Si content of about 5.22at.% as well as good fracture toughness and adhesion strength. The TC4 and AISI 1045 cutting tool inserts with 4μm coating thickness have the minimum cutting forces of about 734.7N and 450.7N, respectively. Besides, tool inserts with a thickness of 3μm have the minimum cutting temperatures of about 510.2∘C and 230.6∘C, respectively.

  15. Optimization of multi response in end milling process of ASSAB XW-42 tool steel with liquid nitrogen cooling using Taguchi-grey relational analysis

    NASA Astrophysics Data System (ADS)

    Norcahyo, Rachmadi; Soepangkat, Bobby O. P.

    2017-06-01

    A research was conducted for the optimization of the end milling process of ASSAB XW-42 tool steel with multiple performance characteristics based on the orthogonal array with Taguchi-grey relational analysis method. Liquid nitrogen was applied as a coolant. The experimental studies were conducted under varying the liquid nitrogen cooling flow rates (FL), and the end milling process variables, i.e., cutting speed (Vc), feeding speed (Vf), and axial depth of cut (Aa). The optimized multiple performance characteristics were surface roughness (SR), flank wear (VB), and material removal rate (MRR). An orthogonal array, signal-to-noise (S/N) ratio, grey relational analysis, grey relational grade, and analysis of variance were employed to study the multiple performance characteristics. Experimental results showed that flow rate gave the highest contribution for reducing the total variation of the multiple responses, followed by cutting speed, feeding speed, and axial depth of cut. The minimum surface roughness, flank wear, and maximum material removal rate could be obtained by using the values of flow rate, cutting speed, feeding speed, and axial depth of cut of 0.5 l/minute, 109.9 m/minute, 440 mm/minute, and 0.9 mm, respectively.

  16. Influence of basketball shoe mass, outsole traction, and forefoot bending stiffness on three athletic movements.

    PubMed

    Worobets, Jay; Wannop, John William

    2015-09-01

    Prior research has shown that footwear can enhance athletic performance. However, public information is not available on what basketball shoe properties should be selected to maximise movement performance. Therefore, the purpose of the study was to investigate the influence of basketball shoe mass, outsole traction, and forefoot bending stiffness on sprinting, jumping, and cutting performance. Each of these three basketball shoe properties was systematically varied by ± 20% to produce three shoe conditions of varying mass, three conditions of varying traction, and three conditions of varying bending stiffness. Each shoe was tested by 20 recreational basketball players completing maximal effort sprints, vertical jumps, and a cutting drill. Outsole traction had the largest influence on performance, as the participants performed significantly worse in all tests when traction was decreased by 20% (p < 0.001), and performed significantly better in the cutting drill when traction was increased by 20% (p = 0.005). Forefoot bending stiffness had a moderate effect on sprint and cutting performance (p = 0.013 and p = 0.016 respectively) and shoe mass was found to have no effect on performance. Therefore, choosing a shoe with relatively high outsole traction and forefoot bending stiffness should be prioritised, and less concern should be focused on selecting the lightest shoe.

  17. Surgical techniques influence local environment of injured spinal cord and cause various grafted cell survival and integration.

    PubMed

    Hou, Shaoping; Saltos, Tatiana M; Iredia, Idiata W; Tom, Veronica J

    2018-01-01

    Cellular transplantation to repair a complete spinal cord injury (SCI) is tremendously challenging due to the adverse local milieu for graft survival and growth. Results from cell transplantation studies yield great variability, which may possibly be due to the surgical techniques employed to induce an SCI. In order to delineate the influence of surgery on such inconsistency, we compared lesion morphology and graft survival as well as integration from different lesion methodologies of SCI. Surgical techniques, including a traditional approach cut+microaspiration, and two new approaches, cut alone as well as crush, were employed to produce a complete SCI, respectively. Approximately half of the rats in each group received injury only, whereas the other half received grafts of fetal brainstem cells into the lesion gap. Eight weeks after injury with or without graft, histological analysis showed that the cut+microaspiration surgery resulted in larger lesion cavities and severe fibrotic scars surrounding the cavity, and cellular transplants rarely formed a tissue bridge to penetrate the barrier. In contrast, the majority of cases treated with cut alone or crush exhibited smaller cavities and less scarring; the grafts expanded and blended extensively with the host tissue, which often built continuous tissue bridging the rostral and caudal cords. Scarring and cavitation were significantly reduced when microaspiration was avoided in SCI surgery, facilitating graft/host tissue fusion for signal transmission. The result suggests that microaspiration frequently causes severe scars and cavities, thus impeding graft survival and integration. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. High speed machinability of the aerospace alloy AA7075 T6 under different cooling conditions

    NASA Astrophysics Data System (ADS)

    Imbrogno, Stano; Rinaldi, Sergio; Suarez, Asier Gurruchaga; Arrazola, Pedro J.; Umbrello, Domenico

    2018-05-01

    This paper describes the results of an experimental investigation aimed to st udy the machinability of AA7075 T6 (160 HV) for aerospace industry at high cutting speeds. The paper investigates the effects of different lubri-cooling strategies (cryogenic, M QL and dry) during high speed turning process on cutting forces, tool wear, chip morphology and cutting temperatures. The cutting speeds selected were 1000m/min, 1250m/min and 1500 m/min, while the feed rate values used were 0.1mm/rev and 0.3 mm/rev. The results of cryogenic and M QL application is compared with dry application. It was found that the cryogenic and M QL lubri-cooling techniques could represent a functional alternative to the common dry cutting application in order to implement a more effect ive high speed turning process. Higher cuttingparameters would be able to increase the productivity and reduce the production costs. The effects of the cutting parameters and on the variables object of study were investigated and the role of the different lubri-cooling conditions was assessed.

  19. Operation Reliability Assessment for Cutting Tools by Applying a Proportional Covariate Model to Condition Monitoring Information

    PubMed Central

    Cai, Gaigai; Chen, Xuefeng; Li, Bing; Chen, Baojia; He, Zhengjia

    2012-01-01

    The reliability of cutting tools is critical to machining precision and production efficiency. The conventional statistic-based reliability assessment method aims at providing a general and overall estimation of reliability for a large population of identical units under given and fixed conditions. However, it has limited effectiveness in depicting the operational characteristics of a cutting tool. To overcome this limitation, this paper proposes an approach to assess the operation reliability of cutting tools. A proportional covariate model is introduced to construct the relationship between operation reliability and condition monitoring information. The wavelet packet transform and an improved distance evaluation technique are used to extract sensitive features from vibration signals, and a covariate function is constructed based on the proportional covariate model. Ultimately, the failure rate function of the cutting tool being assessed is calculated using the baseline covariate function obtained from a small sample of historical data. Experimental results and a comparative study show that the proposed method is effective for assessing the operation reliability of cutting tools. PMID:23201980

  20. Counterbalance of cutting force for advanced milling operations

    NASA Astrophysics Data System (ADS)

    Tsai, Nan-Chyuan; Shih, Li-Wen; Lee, Rong-Mao

    2010-05-01

    The goal of this work is to concurrently counterbalance the dynamic cutting force and regulate the spindle position deviation under various milling conditions by integrating active magnetic bearing (AMB) technique, fuzzy logic algorithm and an adaptive self-tuning feedback loop. Since the dynamics of milling system is highly determined by a few operation conditions, such as speed of spindle, cut depth and feedrate, therefore the dynamic model for cutting process is more appropriate to be constructed by experiments, instead of using theoretical approach. The experimental data, either for idle or cutting, are utilized to establish the database of milling dynamics so that the system parameters can be on-line estimated by employing the proposed fuzzy logic algorithm as the cutting mission is engaged. Based on the estimated milling system model and preset operation conditions, i.e., spindle speed, cut depth and feedrate, the current cutting force can be numerically estimated. Once the current cutting force can be real-time estimated, the corresponding compensation force can be exerted by the equipped AMB to counterbalance the cutting force, in addition to the spindle position regulation by feedback of spindle position. On the other hand, for the magnetic force is nonlinear with respect to the applied electric current and air gap, the characteristics of the employed AMB is investigated also by experiments and a nonlinear mathematic model, in terms of air gap between spindle and electromagnetic pole and coil current, is developed. At the end, the experimental simulations on realistic milling are presented to verify the efficacy of the fuzzy controller for spindle position regulation and the capability of the dynamic cutting force counterbalance.

  1. Molecular assay to fraud identification of meat products.

    PubMed

    Doosti, Abbas; Ghasemi Dehkordi, Payam; Rahimi, Ebrahim

    2014-01-01

    Detection of species fraud in meat products is important for consumer protection and food industries. A molecular technique such as PCR method for detection of beef, sheep, pork, chicken, donkey, and horse meats in food products was established. The purpose of this study was to identification of fraud and adulteration in industrial meat products by PCR-RFLP assay in Iran. In present study, 224 meat products include 68 sausages, 48 frankfurters, 55 hamburgers, 33 hams and 20 cold cut meats were collected from different companies and food markets in Iran. Genomic DNA was extracted and PCR was performed for gene amplification of meat species using specific oligonucleotid primers. Raw meat samples are served as the positive control. For differentiation between donkey's and horse's meat, the mitochondrial DNA segment (cytochrome-b gene) was amplified and products were digested with AluI restriction enzyme. Results showed that 6 of 68 fermented sausages (8.82%), 4 of 48 frankfurters (8.33%), 4 of 55 hamburgers (7.27%), 2 of 33 hams (6.6%), and 1 of 20 cold cut meat (5%) were found to contain Haram (unlawful or prohibited) meat. These results indicate that 7.58% of the total samples were not containing Halal (lawful or permitted) meat and have another meat. These findings showed that molecular methods such as PCR and PCR-RFLP are potentially reliable techniques for detection of meat type in meat products for Halal authentication.

  2. Hydrogen peroxide test for intraoperative bile leak detection.

    PubMed

    Trehan, V; Rao, Pankaj P; Naidu, C S; Sharma, Anuj K; Singh, A K; Sharma, Sanjay; Gaur, Amit; Kulkarni, S V; Pathak, N

    2017-07-01

    Bile leakage (BL) is a common complication following liver surgery, ranging from 3 to 27% in different series. To reduce the incidence of post-operative BL various BL tests have been applied since ages, but no method is foolproof and every method has their own limitations. In this study we used a relatively simpler technique to detect the BL intra-operatively. Topical application of 1.5% diluted hydrogen peroxide (H 2 O 2 ) was used to detect the BL from cut surface of liver and we compared this with conventional saline method to know the efficacy. A total of 31 patients included all patients who underwent liver resection and donor hepatectomies as part of Living Donor Liver Transplantation. After complete liver resection, the conventional saline test followed by topical diluted 1.5% H 2 O 2 test was performed on all. A BL was demonstrated in 11 patients (35.48%) by the conventional saline method and in 19 patients (61.29%) by H 2 O 2 method. Statistically compared by Wilcoxon signed-rank test showed significant difference ( P  = 0.014) for minor liver resections group and ( P  = 0.002) for major liver resections group. The topical application of H 2 O 2 is a simple and effective method of detection of BL from cut surface of liver. It is an easy, non-invasive, cheap, less time consuming, reproducible, and sensitive technique with no obvious disadvantages.

  3. An Integrated Method Based on PSO and EDA for the Max-Cut Problem.

    PubMed

    Lin, Geng; Guan, Jian

    2016-01-01

    The max-cut problem is NP-hard combinatorial optimization problem with many real world applications. In this paper, we propose an integrated method based on particle swarm optimization and estimation of distribution algorithm (PSO-EDA) for solving the max-cut problem. The integrated algorithm overcomes the shortcomings of particle swarm optimization and estimation of distribution algorithm. To enhance the performance of the PSO-EDA, a fast local search procedure is applied. In addition, a path relinking procedure is developed to intensify the search. To evaluate the performance of PSO-EDA, extensive experiments were carried out on two sets of benchmark instances with 800 to 20,000 vertices from the literature. Computational results and comparisons show that PSO-EDA significantly outperforms the existing PSO-based and EDA-based algorithms for the max-cut problem. Compared with other best performing algorithms, PSO-EDA is able to find very competitive results in terms of solution quality.

  4. Accuracy, reliability, and timing of visual evaluations of decay in fresh-cut lettuce

    USDA-ARS?s Scientific Manuscript database

    Visual assessments are used for evaluating the quality of food products, such as fresh-cut lettuce packaged in bags with modified atmosphere. We have compared the accuracy and the reliability of visual evaluations of decay on fresh-cut lettuce performed with experienced and inexperienced raters. In ...

  5. Joining dissimilar materials using Friction Stir scribe technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Upadhyay, Piyush; Hovanski, Yuri; Jana, Saumyadeep

    2016-10-03

    The ability to effectively join materials with vastly different melting points like Aluminum-Steel, Polymer composites - metals has been one of the road blocks in realizing multi-material components for light weighting efforts. Friction stir scribe (FSS) technique is a promising method that produces continuous overlap joint between materials with vastly different melting regimes and high temperature flow characteristics. FSS uses an offset cutting tool at the tip of the FSW pin to create an insitu mechanical interlock between material interfaces. With investments from Vehicle Technology office, US DOE and several automotive manufacturers and suppliers PNNL is developing the FSS processmore » and has demonstrated viability of joining several material combinations. Details of welding trails, unique challenges and mitigation strategies in different material combinations will be discussed. Joint characterization including mechanical tests and joint performances will also be presented.« less

  6. Use of an holistic approach for effective adoption of User-Centred-Design techniques in diabetes disease management: Experiences in user need elicitation.

    PubMed

    Fico, Giuseppe; Arredondo, Maria Teresa

    2015-01-01

    One of the most important challenges of designing eHealth tools for Chronic Disease Management is to understand how transforming cutting-edge innovations in something that can impact the current clinical practice and improve the performance of the health care systems. The adoption of User Centered Design techniques is fundamental in order to integrate these systems in an effective and successful way. The work presented in this paper describe the methodologies used in the context of two multidisciplinary research projects, METABO and MOSAIC. The adoption of the methodologies have been driven by the CeHRes Roamap, a holistic framework that support participatory development of eHealth. The work reported in this paper describes the results of the first two (out of the five) phases in eliciting user needs.

  7. Performance of Slash Pine Bare-Root Seedlings and Containerized Rooted Cuttings Planted on Five Dates in Louisiana

    Treesearch

    Alper Akgul; Michael G. Messina; Alan Wilson; Joe Weber

    2004-01-01

    Landowners are interested in extending the normal planting season, as well as the comparative field performance, of nursery bare-root seedlings and containerized rooted cuttings. The effect of seasonal planting dates on field performance of two stock types of slash pine (Pinus elliottii Engelm.) was examined. Slash pine bare-root seedlings (BRS) and...

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yuuichi Tooya; Tadahiro Washiya; Kenji Koizumi

    Japan Atomic Energy Agency (JAEA) has been leading feasibility study on commercialized fast reactor cycle systems in Japan. In this study, we have proposed a new disassembly technology by mechanical disassembly system that consists of a mechanical cutting step and a wrapper tube pulling step. In the mechanical disassembly system, high durability mechanical tool grinds the wrapper tube (Slit-cut (S/C) operation in circle direction), and then the wrapper tube is pulled out and removed from the fuel assembly. Then the fuel pins are cut (Crop-cut (C/C) operation at entrance nozzle side) and the entrance nozzle is removed. The fuel pinsmore » are transported to the shearing device in next process. The Fundamental tests were carried out with simulated FBR fuel pins and wrapper tube, and cutting performance and wrapper tube pulling performance has been confirmed by engineering scale. As results, we established an efficient disassembly procedure and the fundamental design of mechanical disassembly system. (authors)« less

  9. A severe artifact in simulation of liquid water using a long cut-off length: Appearance of a strange layer structure

    NASA Astrophysics Data System (ADS)

    Yonetani, Yoshiteru

    2005-04-01

    We report that a severe artifact appeared in molecular dynamics simulation of bulk water using the long cut-off length 18 Å. Our result shows that increasing the cut-off length does not always improve the simulation result. Moreover, the use of the long cut-off length can lead to a spurious result. It is suggested that the simulation of solvated biomolecules using such a long cut-off length, which has been often performed, may contain an unexpected artifact.

  10. Apparatus and method for cutting soft materials, especially meat

    DOEpatents

    Spletzer, Barry L.; Callow, Diane S.; Jones, James F.; Kuehl, Michael A.; Shaw, Dick L.; Scalia, Barbara J.

    2005-10-18

    An apparatus and method for cutting soft materials such as meat. Two or more spirally mounted helical blades are situated between two supports, and the supports are mounted to a shank. The shank is rotated to impart rotary action to the spiral shear blades, and the entire device may be used to perform various cutting operations. The distal or bottom one of the supports may also be a cutting blade, and a number of versions of bottom cutting blades are useable in the practice of the invention.

  11. On Computations of Duct Acoustics with Near Cut-Off Frequency

    NASA Technical Reports Server (NTRS)

    Dong, Thomas Z.; Povinelli, Louis A.

    1997-01-01

    The cut-off is a unique feature associated with duct acoustics due to the presence of duct walls. A study of this cut-off effect on the computations of duct acoustics is performed in the present work. The results show that the computation of duct acoustic modes near cut-off requires higher numerical resolutions than others to avoid being numerically cut off. Duct acoustic problems in Category 2 are solved by the DRP finite difference scheme with the selective artificial damping method and results are presented and compared to reference solutions.

  12. Interaction Structures for Narrow-Band Millimeter-Wave Communications TWTs.

    DTIC Science & Technology

    1981-04-01

    comb would be cut from a single piece of copper, probably by a reliable but inexpensive technique such as electroerosion or "chemical milling". All...dimensional. These features would facilitate fabrication by chemical (photo-lithographic) or laser milling as well as by electroerosion with traveling...c, d) has also been implemented since this design should be more robust as well as compatible with electroerosion cutting using a traveling-wire

  13. Use of the piezosurgery technique for cutting bones in the autotransplantation of unerupted third molars.

    PubMed

    Koszowski, Rafał; Morawiec, Tadeusz; Bubiłek-Bogacz, Anna

    2013-01-01

    Autotransplantation is a well-known method used in oral surgery. However, risk of failure, most commonly resulting from root resorption of the transplanted tooth or ankylosis, is quite high. Piezosurgery with specific device tip vibration frequencies enables selective tissue cutting, and therefore, tooth buds or teeth can easily be removed from bones with little injury to periodontal fibers or bud follicles.

  14. Investigations on Surface Milling of Hardened AISI 4140 Steel with Pulse Jet MQL Applicator

    NASA Astrophysics Data System (ADS)

    Bashir, Mahmood Al; Mia, Mozammel; Dhar, Nikhil Ranjan

    2018-06-01

    In this article, an experimental investigation was performed in milling hardened AISI 4140 steel of hardness 40 HRC. The machining was performed in both dry and minimal quantity lubricant (MQL) conditions, as part of neat machining, to make a strong comparison of the undertaken machining environments. The MQL was impinged int the form of pulse jet, by using the specially developed pulse-jet-attachment, to ensure that the cutting fluid can be applied in different timed pulses and quantities at critical zones. The tool wear, cutting force and surface roughness were taken as the quality responses while cutting speed, table feed rate and flow rate of the pulse were considered as influential factors. The depth of cut was kept constant at 1.50 mm because of its less significant effects and the straight oil was adopted as cutting fluid in pulse-jet-MQL. The effects of different factors, on the quality responses, are analyzed using ANOVA. It is observed that MQL applicator system exhibits overall better performance when compared to dry milling by reducing surface roughness, cutting force and prolonging tool life but a flow rate of 150 ml/h has tremendous effects on the responses. This investigation and afterward results are expected to aid the industrial practitioner and researcher to adopt the pulse-MQL in high speed milling to prolong tool life, reduce tool wear, diminish cutting force generation and promote better surface finish.

  15. Investigations on Surface Milling of Hardened AISI 4140 Steel with Pulse Jet MQL Applicator

    NASA Astrophysics Data System (ADS)

    Bashir, Mahmood Al; Mia, Mozammel; Dhar, Nikhil Ranjan

    2016-06-01

    In this article, an experimental investigation was performed in milling hardened AISI 4140 steel of hardness 40 HRC. The machining was performed in both dry and minimal quantity lubricant (MQL) conditions, as part of neat machining, to make a strong comparison of the undertaken machining environments. The MQL was impinged int the form of pulse jet, by using the specially developed pulse-jet-attachment, to ensure that the cutting fluid can be applied in different timed pulses and quantities at critical zones. The tool wear, cutting force and surface roughness were taken as the quality responses while cutting speed, table feed rate and flow rate of the pulse were considered as influential factors. The depth of cut was kept constant at 1.50 mm because of its less significant effects and the straight oil was adopted as cutting fluid in pulse-jet-MQL. The effects of different factors, on the quality responses, are analyzed using ANOVA. It is observed that MQL applicator system exhibits overall better performance when compared to dry milling by reducing surface roughness, cutting force and prolonging tool life but a flow rate of 150 ml/h has tremendous effects on the responses. This investigation and afterward results are expected to aid the industrial practitioner and researcher to adopt the pulse-MQL in high speed milling to prolong tool life, reduce tool wear, diminish cutting force generation and promote better surface finish.

  16. The effects of femoral neck cut, cable tension, and muscles forces on the greater trochanter fixation.

    PubMed

    Petit, Yvan; Cloutier, Luc P; Duke, Kajsa; Laflamme, G Yves

    2012-04-01

    Greater trochanter (GT) stabilization techniques following a fracture or an osteotomy are still showing high levels of postoperative complications. Understanding the effect of femoral neck cut placement, cable tension and muscles forces on GT fragment displacements could help surgeons optimize their techniques. A 3D finite element model has been developed to evaluate, through a statistical experimental design, the impact of the above variables on the GT fragment gap and sliding displacements. Muscles forces were simulating typical daily activities. Stresses were also investigated. The femoral neck cut placement had the most significant effect on the fragment displacement. Lowering it by 5 mm increased the gap and sliding fragment displacements by 288 and 128 %, respectively. Excessive cable tightening provided no significant reduction in fragment displacement. Muscle activities increased the gap and the sliding displacements for all muscle configurations. The maximum total displacement of 0.41 mm was present with a 10 mm femoral neck cut, a cable tension of 178 N, and stair climbing. Caution must be used not to over tighten the cables as the potential damage caused by the increased stress is more significant than any reduction in fragment displacement. Furthermore, preservation of the contact area is important for GT stabilization.

  17. Novel Real-Time Temperature Diagnosis of Conventional Hot-Embossing Process Using an Ultrasonic Transducer

    PubMed Central

    Cheng, Chin-Chi; Yang, Sen-Yeu; Lee, Dasheng

    2014-01-01

    This paper presents an integrated high temperature ultrasonic transducer (HTUT) on a sensor insert and its application for real-time diagnostics of the conventional hot embossing process to fabricate V-cut patterns. The sensor was directly deposited onto the sensor insert of the hot embossing mold by using a sol-gel spray technique. It could operate at temperatures higher than 400 °C and uses an ultrasonic pulse-echo technique. The ultrasonic velocity could indicate the three statuses of the hot embossing process and also evaluate the replication of V-cut patterns on a plastic plate under various processing conditions. The progression of the process, including mold closure, plastic plate softening, cooling and plate detachment inside the mold, was clearly observed using ultrasound. For an ultrasonic velocity range from 2197.4 to 2435.9 m/s, the height of the V-cut pattern decreased from 23.0 to 3.2 μm linearly, with a ratio of −0.078 μm/(m/s). The incompleteness of the replication of the V-cut patterns could be indirectly observed by the ultrasonic signals. This study demonstrates the effectiveness of the ultrasonic sensors and technology for diagnosing the replicating condition of microstructures during the conventional hot embossing process. PMID:25330051

  18. An Experimental Study on Micro Clinching of Metal Foils with Cutting by Laser Shock Forming

    PubMed Central

    Wang, Xiao; Li, Cong; Ma, Youjuan; Shen, Zongbao; Sun, Xianqing; Sha, Chaofei; Gao, Shuai; Li, Liyin; Liu, Huixia

    2016-01-01

    This paper describes a novel technique for joining similar and dissimilar metal foils, namely micro clinching with cutting by laser shock forming. A series of experiments were conducted to study the deformation behavior of single layer material, during which many important process parameters were determined. The process window of the 1060 pure aluminum foils and annealed copper foils produced by micro clinching with cutting was analyzed. Moreover, similar material combination (annealed copper foils) and dissimilar material combination (1060 pure aluminum foils and 304 stainless steel foils) were successfully achieved. The effect of laser energy on the interlock and minimum thickness of upper foils was investigated. In addition, the mechanical strength of different material combinations joined by micro clinching with cutting was measured in single lap shearing tests. According to the achieved results, this novel technique is more suitable for material combinations where the upper foil is thicker than lower foil. With the increase of laser energy, the interlock increased while the minimum thickness of upper foil decreased gradually. The shear strength of 1060 pure aluminum foils and 304 stainless steel foils combination was three times as large as that of 1060 pure aluminum foils and annealed copper foils combination. PMID:28773692

  19. A Tapered Aluminium Microelectrode Array for Improvement of Dielectrophoresis-Based Particle Manipulation

    PubMed Central

    Buyong, Muhamad Ramdzan; Larki, Farhad; Faiz, Mohd Syafiq; Hamzah, Azrul Azlan; Yunas, Jumrail; Majlis, Burhanuddin Yeop

    2015-01-01

    In this work, the dielectrophoretic force (FDEP) response of Aluminium Microelectrode Arrays with tapered profile is investigated through experimental measurements and numerical simulations. A standard CMOS processing technique with a step for the formation of a tapered profile resist is implemented in the fabrication of Tapered Aluminium Microelectrode Arrays (TAMA). The FDEP is investigated through analysis of the Clausius-Mossotti factor (CMF) and cross-over frequency (fxo). The performance of TAMA with various side wall angles is compared to that of microelectrodes with a straight cut sidewall profile over a wide range of frequencies through FEM numerical simulations. Additionally, electric field measurement (EFM) is performed through scanning probe microscopy (SPM) in order to obtain the region of force focus in both platforms. Results showed that the tapered profile microelectrodes with angles between 60° and 70° produce the highest electric field gradient on the particles. Also, the region of the strongest electric field in TAMA is located at the bottom and top edge of microelectrode while the strongest electric field in microelectrodes with straight cut profile is found at the top corner of the microelectrode. The latter property of microelectrodes improves the probability of capturing/repelling the particles at the microelectrode’s side wall. PMID:25970255

  20. Transoral laser microsurgery for laryngeal cancer: A primer and review of laser dosimetry

    PubMed Central

    Rubinstein, Marc

    2010-01-01

    Transoral laser microsurgery (TLM) is an emerging technique for the management of laryngeal and other head and neck malignancies. It is increasingly being used in place of traditional open surgery because of lower morbidity and improved organ preservation. Since the surgery is performed from the inside working outward as opposed to working from the outside in, there is less damage to the supporting structures that lie external to the tumor. Coupling the laser to a micromanipulator and a microscope allows precise tissue cutting and hemostasis; thereby improving visualization and precise ablation. The basic approach and principles of performing TLM, the devices currently in use, and the associated dosimetry parameters will be discussed. The benefits of using TLM over conventional surgery, common complications and the different settings used depending on the location of the tumor will also be discussed. Although the CO2 laser is the most versatile and the best-suited laser for TLM applications, a variety of lasers and different parameters are used in the treatment of laryngeal cancer. Improved instrumentation has lead to an increased utilization of TLM by head and neck cancer surgeons and has resulted in improved outcomes. Laser energy levels and spot size are adjusted to vary the precision of cutting and amount of hemostasis obtained. PMID:20835840

Top