Vadapalli, Sriharsha Babu; Atluri, Kaleswararao; Putcha, Madhu Sudhan; Kondreddi, Sirisha; Kumar, N. Suman; Tadi, Durga Prasad
2016-01-01
Objectives: This in vitro study was designed to compare polyvinyl-siloxane (PVS) monophase and polyether (PE) monophase materials under dry and moist conditions for properties such as surface detail reproduction, dimensional stability, and gypsum compatibility. Materials and Methods: Surface detail reproduction was evaluated using two criteria. Dimensional stability was evaluated according to American Dental Association (ADA) specification no. 19. Gypsum compatibility was assessed by two criteria. All the samples were evaluated, and the data obtained were analyzed by a two-way analysis of variance (ANOVA) and Pearson's Chi-square tests. Results: When surface detail reproduction was evaluated with modification of ADA specification no. 19, both the groups under the two conditions showed no significant difference statistically. When evaluated macroscopically both the groups showed statistically significant difference. Results for dimensional stability showed that the deviation from standard was significant among the two groups, where Aquasil group showed significantly more deviation compared to Impregum group (P < 0.001). Two conditions also showed significant difference, with moist conditions showing significantly more deviation compared to dry condition (P < 0.001). The results of gypsum compatibility when evaluated with modification of ADA specification no. 19 and by giving grades to the casts for both the groups and under two conditions showed no significant difference statistically. Conclusion: Regarding dimensional stability, both impregum and aquasil performed better in dry condition than in moist; impregum performed better than aquasil in both the conditions. When tested for surface detail reproduction according to ADA specification, under dry and moist conditions both of them performed almost equally. When tested according to macroscopic evaluation, impregum and aquasil performed significantly better in dry condition compared to moist condition. In dry condition, both the materials performed almost equally. In moist condition, aquasil performed significantly better than impregum. Regarding gypsum compatibility according to ADA specification, in dry condition both the materials performed almost equally, and in moist condition aquasil performed better than impregum. When tested by macroscopic evaluation, impregum performed better than aquasil in both the conditions. PMID:27583217
Vadapalli, Sriharsha Babu; Atluri, Kaleswararao; Putcha, Madhu Sudhan; Kondreddi, Sirisha; Kumar, N Suman; Tadi, Durga Prasad
2016-01-01
This in vitro study was designed to compare polyvinyl-siloxane (PVS) monophase and polyether (PE) monophase materials under dry and moist conditions for properties such as surface detail reproduction, dimensional stability, and gypsum compatibility. Surface detail reproduction was evaluated using two criteria. Dimensional stability was evaluated according to American Dental Association (ADA) specification no. 19. Gypsum compatibility was assessed by two criteria. All the samples were evaluated, and the data obtained were analyzed by a two-way analysis of variance (ANOVA) and Pearson's Chi-square tests. When surface detail reproduction was evaluated with modification of ADA specification no. 19, both the groups under the two conditions showed no significant difference statistically. When evaluated macroscopically both the groups showed statistically significant difference. Results for dimensional stability showed that the deviation from standard was significant among the two groups, where Aquasil group showed significantly more deviation compared to Impregum group (P < 0.001). Two conditions also showed significant difference, with moist conditions showing significantly more deviation compared to dry condition (P < 0.001). The results of gypsum compatibility when evaluated with modification of ADA specification no. 19 and by giving grades to the casts for both the groups and under two conditions showed no significant difference statistically. Regarding dimensional stability, both impregum and aquasil performed better in dry condition than in moist; impregum performed better than aquasil in both the conditions. When tested for surface detail reproduction according to ADA specification, under dry and moist conditions both of them performed almost equally. When tested according to macroscopic evaluation, impregum and aquasil performed significantly better in dry condition compared to moist condition. In dry condition, both the materials performed almost equally. In moist condition, aquasil performed significantly better than impregum. Regarding gypsum compatibility according to ADA specification, in dry condition both the materials performed almost equally, and in moist condition aquasil performed better than impregum. When tested by macroscopic evaluation, impregum performed better than aquasil in both the conditions.
Performance Evaluation of the United Nations Environment Programme Air Quality Monitoring Unit
This report defines the specifics of the environmental test conditions used in the evaluation (systems and conditions), data observations, summarization of key performance evaluation findings, and ease of use features concerning the UNEP pod.
Thermal performance of MSFC hot air collectors under natural and simulated conditions
NASA Technical Reports Server (NTRS)
Shih, K., Sr.
1977-01-01
The procedures used and the results obtained from an evaluation test program conducted to determine the thermal performance and structural characteristics of selected MSFC--designed hot air collectors under both real and simulated environmental conditions are described. Five collectors were tested in the three phased program. A series of outdoor tests were conducted to determine stagnation temperatures on a typical bright day and to determine each collector's ability to withstand these temperatures. Two of the collectors experienced structural deformation sufficient to eliminate them from the remainder of the test program. A series of outdoor tests to evaluate the thermal performance of collector S/N 10 under certain test conditions were performed followed by a series of indoor tests to evaluate the thermal performance of the collector under closely controlled simulated conditions.
Effects of spatially displaced feedback on remote manipulation tasks
NASA Technical Reports Server (NTRS)
Manahan, Meera K.; Stuart, Mark A.; Bierschwale, John M.; Hwang, Ellen Y.; Legendre, A. J.
1992-01-01
Several studies have been performed to determine the effects on computer and direct manipulation task performance when viewing conditions are spatially displaced. Whether results from these studies can be directly applied to remote manipulation tasks is quenstionable. The objective of this evaluation was to determine the effects of reversed, inverted, and inverted/reversed views on remote manipulation task performance using two 3-Degree of Freedom (DOF) hand controllers and a replica position hand controller. Results showed that trials using the inverted viewing condition showed the worst performance, followed by the inverted/reversed view and the reversed view when using the 2x3 DOF. However, these differences were not significant. The inverted and inverted/reversed viewing conditions were significantly worse than the normal and reversed viewing conditions when using the Kraft Replica. A second evaluation was conducted in which additional trials were performed with each viewing condition to determine the long term effects of spatially displaced views on task performance for the hand controllers. Results of the second evaluation indicated that there was more of a difference in performance between the perturbed viewing conditions and the normal viewing condition with the Kraft Replica than with the 2x3 DOF.
DOT National Transportation Integrated Search
2009-05-01
The evaluation of three Video Detection Systems (VDS) at an instrumented signalized intersection in Rantoul : Illinois, at both stop bar and advance detection zones, was performed under a wide range of lighting and : weather conditions. The evaluated...
Evaluation of FSO System Availability in Haze Condition
NASA Astrophysics Data System (ADS)
Anis, A. A.; Rashidi, C. B. M.; Aljunid, S. A.; Rahman, A. K.
2018-03-01
In this paper, we proposed the evaluation of FSO system availability in haze condition. The atmospheric attenuation by weather conditions in the atmosphere as the most challenging problem of FSO system as the system performance is severely degraded and causing the signal optic to be transmitted poorly. The effects of haze condition on the performance of FSO system is stressed out and focused in this paper. From the evaluation of the analysis, designs of FSO system are proposed to obtain a system with improved link performance in haze conditions. The scattering coefficient and the atmospheric attenuation are determined using Beer’s Lambert equation. From the research, the link performance of the system is greatly improved using Design 2 with minimum BER of 10-127127 and maximu m Q Factor of 23.98. The FSO system using Design 2 has better performance compared to Design 1 in haze condition as the optical signals could penetrate the dense haze better without losing much optical power during the transmission to the scattering.
Performance evaluation approach for the supercritical helium cold circulators of ITER
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vaghela, H.; Sarkar, B.; Bhattacharya, R.
2014-01-29
The ITER project design foresees Supercritical Helium (SHe) forced flow cooling for the main cryogenic components, namely, the superconducting (SC) magnets and cryopumps (CP). Therefore, cold circulators have been selected to provide the required SHe mass flow rate to cope with specific operating conditions and technical requirements. Considering the availability impacts of such machines, it has been decided to perform evaluation tests of the cold circulators at operating conditions prior to the series production in order to minimize the project technical risks. A proposal has been conceptualized, evaluated and simulated to perform representative tests of the full scale SHe coldmore » circulators. The objectives of the performance tests include the validation of normal operating condition, transient and off-design operating modes as well as the efficiency measurement. A suitable process and instrumentation diagram of the test valve box (TVB) has been developed to implement the tests at the required thermodynamic conditions. The conceptual engineering design of the TVB has been developed along with the required thermal analysis for the normal operating conditions to support the performance evaluation of the SHe cold circulator.« less
Thermal performance evaluation of the Solargenics solar collector at outdoor conditions
NASA Technical Reports Server (NTRS)
1978-01-01
Test procedures used during the performance of an evaluation program are presented. The test program was conducted to obtain the following performance data and information on the solar collector. (1) thermal performance data under outdoor conditions; (2) structural behavior of collector under static conditions; (3) effects of long term exposure to material weathering elements. The solargenics is a liquid, single-glazed, flat plate collector. Approximate dimensions of each collector are 240 inches long, 36 inches wide, and 3.5 inches in depth.
Small Scale Trace Contaminant Testing of SA9T at Ambient and Reduced Pressure Conditions
NASA Technical Reports Server (NTRS)
Broerman, Craig; Sweterlitsch, Jeffrey
2011-01-01
A principle concern for air revitalization technology in a closed loop system is the capability to control carbon dioxide (CO2) and humidity (H2O). An amine based sorbent technology, SA9T, has long been evaluated for use in this application and several programs are evaluating it for use in both a cabin as well as space suit applications. While the CO2 and H2O performance of the sorbent has been tested extensively, the question of how trace contaminants impact performance requires further evaluation. This paper presents experimental results of small scale SA9T testing that was performed over a variety of test conditions and with a variety of trace contaminants. Testing evaluated the ability of SA9T media to sufficiently remove CO2 and H2O after exposure to a fully saturated trace contaminant at ambient conditions. Testing also evaluated the impact of CO2 and H2O removal performance at suit loop pressures during cyclic operation with a constant inlet contaminant load. In addition, testing evaluated the performance of SA9T at ambient conditions in a continuous 30-day test with a mixed trace contaminant stream.
Performance evaluation of a mobile satellite system modem using an ALE method
NASA Technical Reports Server (NTRS)
Ohsawa, Tomoki; Iwasaki, Motoya
1990-01-01
Experimental performance of a newly designed demodulation concept is presented. This concept applies an Adaptive Line Enhancer (ALE) to a carrier recovery circuit, which makes pull-in time significantly shorter in noisy and large carrier offset conditions. This new demodulation concept was actually developed as an INMARSAT standard-C modem, and was evaluated. On a performance evaluation, 50 symbol pull-in time is confirmed under 4 dB Eb/No condition.
EVALUATION OF A NEW MEAN SCALED AND MOMENT ADJUSTED TEST STATISTIC FOR SEM.
Tong, Xiaoxiao; Bentler, Peter M
2013-01-01
Recently a new mean scaled and skewness adjusted test statistic was developed for evaluating structural equation models in small samples and with potentially nonnormal data, but this statistic has received only limited evaluation. The performance of this statistic is compared to normal theory maximum likelihood and two well-known robust test statistics. A modification to the Satorra-Bentler scaled statistic is developed for the condition that sample size is smaller than degrees of freedom. The behavior of the four test statistics is evaluated with a Monte Carlo confirmatory factor analysis study that varies seven sample sizes and three distributional conditions obtained using Headrick's fifth-order transformation to nonnormality. The new statistic performs badly in most conditions except under the normal distribution. The goodness-of-fit χ(2) test based on maximum-likelihood estimation performed well under normal distributions as well as under a condition of asymptotic robustness. The Satorra-Bentler scaled test statistic performed best overall, while the mean scaled and variance adjusted test statistic outperformed the others at small and moderate sample sizes under certain distributional conditions.
Performance evaluation of NCDOT w-beam guardrails under MASH TL-2 conditions.
DOT National Transportation Integrated Search
2013-11-01
This report summarizes the research efforts of using finite element modeling and simulations to evaluate the performance : of W-beam guardrails for different heights under MASH Test Level 2 (TL-2) and Test Level 3 (TL-3) impact conditions. A : litera...
DOT National Transportation Integrated Search
2013-10-01
The performance of a microwave radar system for vehicle detection at a railroad grade crossing in Hinsdale, : Illinois, was evaluated through field-testing in favorable (normal, good) weather conditions. The system was : installed at a crossing with ...
DOT National Transportation Integrated Search
2015-01-01
The performance of a microwave radar system for vehicle detection at a railroad grade crossing with quadrant gates was evaluated in : adverse weather conditions: rain (light and torrential), snow (light and heavy), dense fog, and wind. The first part...
DOT National Transportation Integrated Search
2009-03-01
The performance of three video detection systems (VDS): Iteris, Autoscope, and Peek, was evaluated : using a side-by-side installation at a signalized intersection under various adverse weather conditions including : rain and snow in both day and nig...
Bench-Scale Trace Contaminant Testing of SA9T at Ambient and Reduced Pressure Conditions
NASA Technical Reports Server (NTRS)
Broerman, Craig; Sweterlitsch, Jeff
2011-01-01
A principal concern for air revitalization technology in a closed loop system is the capability to control carbon dioxide (CO2) and humidity (H2O). An amine based sorbent technology, SA9T, has been evaluated for use in this application and several programs are evaluating it for use in both cabin and space suit applications. While the CO2 and H2O performance of the sorbent has been tested extensively, the question of how trace contaminants impact performance requires further evaluation. This paper presents experimental results of bench-scale SA9T testing that was performed under a variety of test conditions and with several different trace contaminants. Tests were conducted to determine if the capacity of the SA9T media to sufficiently remove CO2 and H2O is compromised after exposure to a fully saturated trace contaminant at ambient conditions. Tests also were conducted to evaluate the performance of SA9T at ambient conditions in a continuous 30-day test with a mixed trace contaminant stream. In addition, testing also evaluated the impact of CO2 and H2O removal performance at suit loop pressures (29.6 KPa/4.3 psia) during cyclic operation with a constant inlet contaminant load.
The relationship of post-event processing to self-evaluation of performance in social anxiety.
Brozovich, Faith; Heimberg, Richard G
2011-06-01
Socially anxious and control participants engaged in a social interaction with a confederate and then wrote about themselves or the other person (i.e., self-focused post-event processing [SF-PEP] vs. other-focused post-event processing [OF-PEP]) and completed several questionnaires. One week later, participants completed measures concerning their evaluation of their performance in the social interaction and the degree to which they engaged in post-event processing (PEP) during the week. Socially anxious individuals evaluated their performance in the social interaction more poorly than control participants, both immediately after and 1 week later. Socially anxious individuals assigned to the SF-PEP condition displayed fewer positive feelings about their performance compared to the socially anxious individuals in the OF-PEP condition as well as controls in either condition. Also, the trait tendency to engage in PEP moderated the effect of social anxiety on participants' evaluation of their performance in the interaction, such that high socially anxious individuals with high trait PEP scores evaluated themselves in the interaction more negatively at the later assessment. These results suggest that PEP and other self-evaluative processes may perpetuate the cycle of social anxiety. Copyright © 2011. Published by Elsevier Ltd.
ERIC Educational Resources Information Center
vonWurmb, Elizabeth C.
2013-01-01
This dissertation undertakes an analysis of 1,044 performance evaluations from New York State School Music Association (NYSSMA) Spring Festival solo adjudication ratings of student performers from a large suburban school district. It relies on results of evaluations of observed performances, and takes these evaluations as assessments of what the…
Physical Evaluation of Cleaning Performance: We Are Only Fooling Ourselves
NASA Technical Reports Server (NTRS)
Pratz, Earl; McCool, A. (Technical Monitor)
2000-01-01
Surface cleaning processes are normally evaluated using visual physical properties such as discolorations, streaking, staining and water-break-free conditions. There is an assumption that these physical methods will evaluate all surfaces all the time for all subsequent operations. We have found that these physical methods are lacking in sensitivity and selectivity with regard to surface residues and subsequent process performance. We will report several conditions where evaluations using visual physical properties are lacking. We will identify possible alternative methods and future needs for surface evaluations.
Impact of study design on development and evaluation of an activity-type classifier.
van Hees, Vincent T; Golubic, Rajna; Ekelund, Ulf; Brage, Søren
2013-04-01
Methods to classify activity types are often evaluated with an experimental protocol involving prescribed physical activities under confined (laboratory) conditions, which may not reflect real-life conditions. The present study aims to evaluate how study design may impact on classifier performance in real life. Twenty-eight healthy participants (21-53 yr) were asked to wear nine triaxial accelerometers while performing 58 activity types selected to simulate activities in real life. For each sensor location, logistic classifiers were trained in subsets of up to 8 activities to distinguish between walking and nonwalking activities and were then evaluated in all 58 activities. Different weighting factors were used to convert the resulting confusion matrices into an estimation of the confusion matrix as would apply in the real-life setting by creating four different real-life scenarios, as well as one traditional laboratory scenario. The sensitivity of a classifier estimated with a traditional laboratory protocol is within the range of estimates derived from real-life scenarios for any body location. The specificity, however, was systematically overestimated by the traditional laboratory scenario. Walking time was systematically overestimated, except for lower back sensor data (range: 7-757%). In conclusion, classifier performance under confined conditions may not accurately reflect classifier performance in real life. Future studies that aim to evaluate activity classification methods are warranted to pay special attention to the representativeness of experimental conditions for real-life conditions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Breuker, M.S.; Braun, J.E.
This paper presents a detailed evaluation of the performance of a statistical, rule-based fault detection and diagnostic (FDD) technique presented by Rossi and Braun (1997). Steady-state and transient tests were performed on a simple rooftop air conditioner over a range of conditions and fault levels. The steady-state data without faults were used to train models that predict outputs for normal operation. The transient data with faults were used to evaluate FDD performance. The effect of a number of design variables on FDD sensitivity for different faults was evaluated and two prototype systems were specified for more complete evaluation. Good performancemore » was achieved in detecting and diagnosing five faults using only six temperatures (2 input and 4 output) and linear models. The performance improved by about a factor of two when ten measurements (three input and seven output) and higher order models were used. This approach for evaluating and optimizing the performance of the statistical, rule-based FDD technique could be used as a design and evaluation tool when applying this FDD method to other packaged air-conditioning systems. Furthermore, the approach could also be modified to evaluate the performance of other FDD methods.« less
Kinematic Analysis and Performance Evaluation of Novel PRS Parallel Mechanism
NASA Astrophysics Data System (ADS)
Balaji, K.; Khan, B. Shahul Hamid
2018-02-01
In this paper, a 3 DoF (Degree of Freedom) novel PRS (Prismatic-Revolute- Spherical) type parallel mechanisms has been designed and presented. The combination of striaght and arc type linkages for 3 DOF parallel mechanism is introduced for the first time. The performances of the mechanisms are evaluated based on the indices such as Minimum Singular Value (MSV), Condition Number (CN), Local Conditioning Index (LCI), Kinematic Configuration Index (KCI) and Global Conditioning Index (GCI). The overall reachable workspace of all mechanisms are presented. The kinematic measure, dexterity measure and workspace analysis for all the mechanism have been evaluated and compared.
DOT National Transportation Integrated Search
1982-05-01
Twelve healthy young men were evaluated in each of four experimental conditions involving the possible combinations of two exercise conditions given prior to performance testing (1 h of heavy exercise vs. no exercise) and two altitude conditions (gro...
Pulse Jet Mixing Tests With Noncohesive Solids
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meyer, Perry A.; Bamberger, Judith A.; Enderlin, Carl W.
2009-05-11
This report summarizes results from pulse jet mixing (PJM) tests with noncohesive solids in Newtonian liquid conducted during FY 2007 and 2008 to support the design of mixing systems for the Hanford Waste Treatment and Immobilization Plant (WTP). Tests were conducted at three geometric scales using noncohesive simulants. The test data were used to independently develop mixing models that can be used to predict full-scale WTP vessel performance and to rate current WTP mixing system designs against two specific performance requirements. One requirement is to ensure that all solids have been disturbed during the mixing action, which is important tomore » release gas from the solids. The second requirement is to maintain a suspended solids concentration below 20 weight percent at the pump inlet. The models predict the height to which solids will be lifted by the PJM action, and the minimum velocity needed to ensure all solids have been lifted from the floor. From the cloud height estimate we can calculate the concentration of solids at the pump inlet. The velocity needed to lift the solids is slightly more demanding than "disturbing" the solids, and is used as a surrogate for this metric. We applied the models to assess WTP mixing vessel performance with respect to the two perform¬ance requirements. Each mixing vessel was evaluated against these two criteria for two defined waste conditions. One of the wastes was defined by design limits and one was derived from Hanford waste characterization reports. The assessment predicts that three vessel types will satisfy the design criteria for all conditions evaluated. Seven vessel types will not satisfy the performance criteria used for any of the conditions evaluated. The remaining three vessel types provide varying assessments when the different particle characteristics are evaluated. The assessment predicts that three vessel types will satisfy the design criteria for all conditions evaluated. Seven vessel types will not satisfy the performance criteria used for any of the conditions evaluated. The remaining three vessel types provide varying assessments when the different particle characteristics are evaluated. The HLP-022 vessel was also evaluated using 12 m/s pulse jet velocity with 6-in. nozzles, and this design also did not satisfy the criteria for all of the conditions evaluated.« less
Leue, Anja; Cano Rodilla, Carmen; Beauducel, André
2015-01-01
Individuals typically evaluate whether their performance and the obtained feedback match. Previous research has shown that feedback negativity (FN) depends on outcome probability and feedback valence. It is, however, less clear to what extent previous effects of outcome probability on FN depend on self-evaluations of response correctness. Therefore, we investigated the effects of outcome probability on FN amplitude in a simple go/no-go task that allowed for the self-evaluation of response correctness. We also investigated effects of performance incompatibility and feedback valence. In a sample of N = 22 participants, outcome probability was manipulated by means of precues, feedback valence by means of monetary feedback, and performance incompatibility by means of feedback that induced a match versus mismatch with individuals' performance. We found that the 100% outcome probability condition induced a more negative FN following no-loss than the 50% outcome probability condition. The FN following loss was more negative in the 50% compared to the 100% outcome probability condition. Performance-incompatible loss resulted in a more negative FN than performance-compatible loss. Our results indicate that the self-evaluation of the correctness of responses should be taken into account when the effects of outcome probability and expectation mismatch on FN are investigated. PMID:26783525
Leue, Anja; Cano Rodilla, Carmen; Beauducel, André
2015-01-01
Individuals typically evaluate whether their performance and the obtained feedback match. Previous research has shown that feedback negativity (FN) depends on outcome probability and feedback valence. It is, however, less clear to what extent previous effects of outcome probability on FN depend on self-evaluations of response correctness. Therefore, we investigated the effects of outcome probability on FN amplitude in a simple go/no-go task that allowed for the self-evaluation of response correctness. We also investigated effects of performance incompatibility and feedback valence. In a sample of N = 22 participants, outcome probability was manipulated by means of precues, feedback valence by means of monetary feedback, and performance incompatibility by means of feedback that induced a match versus mismatch with individuals' performance. We found that the 100% outcome probability condition induced a more negative FN following no-loss than the 50% outcome probability condition. The FN following loss was more negative in the 50% compared to the 100% outcome probability condition. Performance-incompatible loss resulted in a more negative FN than performance-compatible loss. Our results indicate that the self-evaluation of the correctness of responses should be taken into account when the effects of outcome probability and expectation mismatch on FN are investigated.
Philippot, Pierre; Vrielynck, Nathalie; Muller, Valérie
2010-12-01
The present study examined the impact of different modes of processing anxious apprehension on subsequent anxiety and performance in a stressful speech task. Participants were informed that they would have to give a speech on a difficult topic while being videotaped and evaluated on their performance. They were then randomly assigned to one of three conditions. In a specific processing condition, they were encouraged to explore in detail all the specific aspects (thoughts, emotions, sensations) they experienced while anticipating giving the speech; in a general processing condition, they had to focus on the generic aspects that they would typically experience during anxious anticipation; and in a control, no-processing condition, participants were distracted. Results revealed that at the end of the speech, participants in the specific processing condition reported less anxiety than those in the two other conditions. They were also evaluated by judges to have performed better than those in the control condition, who in turn did better than those in the general processing condition. Copyright © 2010. Published by Elsevier Ltd.
Experimental Evaluation of High Performance Integrated Heat Pump
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, William A; Berry, Robert; Durfee, Neal
2016-01-01
Integrated heat pump (IHP) technology provides significant potential for energy savings and comfort improvement for residential buildings. In this study, we evaluate the performance of a high performance IHP that provides space heating, cooling, and water heating services. Experiments were conducted according to the ASHRAE Standard 206-2013 where 24 test conditions were identified in order to evaluate the IHP performance indices based on the airside performance. Empirical curve fits of the unit s compressor maps are used in conjunction with saturated condensing and evaporating refrigerant conditions to deduce the refrigerant mass flowrate, which, in turn was used to evaluate themore » refrigerant side performance as a check on the airside performance. Heat pump (compressor, fans, and controls) and water pump power were measured separately per requirements of Standard 206. The system was charged per the system manufacturer s specifications. System test results are presented for each operating mode. The overall IHP performance metrics are determined from the test results per the Standard 206 calculation procedures.« less
Impact of Motivation on Cognitive Control in the Context of Vigilance Lowering: An ERP Study
ERIC Educational Resources Information Center
Bonnefond, Anne; Doignon-Camus, Nadege; Hoeft, Alain; Dufour, Andre
2011-01-01
We assessed the effects of time-on-task on cognitive control expressed by the CRN/Nc and the extent to which motivation modulates this relationship. We utilized two groups of participants, who were told that their performance would (evaluation condition) or would not (control condition) be evaluated online. Both groups performed a version of the…
Adaptive strategies of remote systems operators exposed to perturbed camera-viewing conditions
NASA Technical Reports Server (NTRS)
Stuart, Mark A.; Manahan, Meera K.; Bierschwale, John M.; Sampaio, Carlos E.; Legendre, A. J.
1991-01-01
This report describes a preliminary investigation of the use of perturbed visual feedback during the performance of simulated space-based remote manipulation tasks. The primary objective of this NASA evaluation was to determine to what extent operators exhibit adaptive strategies which allow them to perform these specific types of remote manipulation tasks more efficiently while exposed to perturbed visual feedback. A secondary objective of this evaluation was to establish a set of preliminary guidelines for enhancing remote manipulation performance and reducing the adverse effects. These objectives were accomplished by studying the remote manipulator performance of test subjects exposed to various perturbed camera-viewing conditions while performing a simulated space-based remote manipulation task. Statistical analysis of performance and subjective data revealed that remote manipulation performance was adversely affected by the use of perturbed visual feedback and performance tended to improve with successive trials in most perturbed viewing conditions.
Evaluation of Process Performance for Sustainable Hard Machining
NASA Astrophysics Data System (ADS)
Rotella, Giovanna; Umbrello, Domenico; , Oscar W. Dillon, Jr.; Jawahir, I. S.
This paper aims to evaluate the sustainability performance of machining operation of through-hardening steel, AISI 52100, taking into account the impact of the material removal process in its various aspects. Experiments were performed for dry and cryogenic cutting conditions using chamfered cubic boron nitride (CBN) tool inserts at varying cutting conditions (cutting speed and feed rate). Cutting forces, mechanical power, tool wear, white layer thickness, surface roughness and residual stresses were investigated in order to evaluate the effects of extreme in-process cooling on the machined surface. The results indicate that cryogenic cooling has the potential to be used for surface integrity enhancement for improved product life and more sustainable functional performance.
Subsurface condition evaluation for asphalt pavement preservation treatments.
DOT National Transportation Integrated Search
2013-04-01
This report presents a case study on the SR70 section with microsurface for understanding its performance; a development of a : methodology for evaluating the asphalt pavement subsurface condition for applying pavement preservation treatments; and...
Development of GUI Type On-Line Condition Monitoring Program for a Turboprop Engine Using Labview
NASA Astrophysics Data System (ADS)
Kong, Changduk; Kim, Keonwoo
2011-12-01
Recently, an aero gas turbine health monitoring system has been developed for precaution and maintenance action against faults or performance degradations of the advanced propulsion system which occurs in severe environments such as high altitude, foreign object damage particles, hot and heavy rain and snowy atmospheric conditions. However to establish this health monitoring system, the online condition monitoring program is firstly required, and the program must monitor the engine performance trend through comparison between measured engine performance data and base performance results calculated by base engine performance model. This work aims to develop a GUI type on-line condition monitoring program for the PT6A-67 turboprop engine of a high altitude and long endurance operation UAV using LabVIEW. The base engine performance of the on-line condition monitoring program is simulated using component maps inversely generated from the limited performance deck data provided by engine manufacturer. The base engine performance simulation program is evaluated because analysis results by this program agree well with the performance deck data. The proposed on-line condition program can monitor the real engine performance as well as the trend through precise comparison between clean engine performance results calculated by the base performance simulation program and measured engine performance signals. In the development phase of this monitoring system, a signal generation module is proposed to evaluate the proposed online monitoring system. For user friendly purpose, all monitoring program are coded by LabVIEW, and monitoring examples are demonstrated using the proposed GUI type on-condition monitoring program.
Performance evaluation and placement analysis of w-beam guardrails behind curbs.
DOT National Transportation Integrated Search
2014-12-15
This report summarizes the research efforts of using finite element modeling and simulations to evaluate the performance : of NCDOT W-beam guardrails behind curbs under MASH TL-2 impact conditions. A literature review is included on : performance eva...
Performance evaluation of the solar kinetics T-700 line concentrating solar collector
NASA Technical Reports Server (NTRS)
1981-01-01
A performance evaluation of the solar kinetics T-700 line concentrating solar collector is reported. Collector descriptions, summary, test conditions, test equipment, test requirements and procedures, and an analysis of the various tests performed are described.
Performance evaluation of a second-generation elastic loop mobility system
NASA Technical Reports Server (NTRS)
Melzer, K. J.; Swanson, G. D.
1974-01-01
Tests were conducted to evaluate the mobility performance of a second-generation Elastic Loop Mobility System (ELMS II). Performance on level test lanes and slopes of lunar soil simulant (LSS) and obstacle-surmounting and crevasse-crossing capabilities were investigated. In addition, internal losses and contact pressure distributions were evaluated. To evaluate the soft-soil performance, two basic soil conditions were tested: loose (LSS1) and dense (LSS5). These conditions embrace the spectrum of soil strengths tested during recent studies for NASA related to the mobility performance of the LRV. Data indicated that for the tested range of the various performance parameters, performance was independent of unit load (contact pressure) and ELMS II drum angular velocity, but was influenced by soil strength and ELMS pitch mode. Power requirements were smaller at a given system output for dense soil than for loose soil. The total system output in terms of pull developed or slope-climbing capability was larger for the ELMS II operating in restrained-pitch mode than in free-pitch mode.
NASA Astrophysics Data System (ADS)
Scaduto, Lucimara C. N.; Malavolta, Alexandre T.; Modugno, Rodrigo G.; Vales, Luiz F.; Carvalho, Erica G.; Evangelista, Sérgio; Stefani, Mario A.; de Castro Neto, Jarbas C.
2017-11-01
The first Brazilian remote sensing multispectral camera (MUX) is currently under development at Opto Eletronica S.A. It consists of a four-spectral-band sensor covering a 450nm to 890nm wavelength range. This camera will provide images within a 20m ground resolution at nadir. The MUX camera is part of the payload of the upcoming Sino-Brazilian satellites CBERS 3&4 (China-Brazil Earth Resource Satellite). The preliminary alignment between the optical system and the CCD sensor, which is located at the focal plane assembly, was obtained in air condition, clean room environment. A collimator was used for the performance evaluation of the camera. The preliminary performance evaluation of the optical channel was registered by compensating the collimator focus position due to changes in the test environment, as an air-to-vacuum environment transition leads to a defocus process in this camera. Therefore, it is necessary to confirm that the alignment of the camera must always be attained ensuring that its best performance is reached for an orbital vacuum condition. For this reason and as a further step on the development process, the MUX camera Qualification Model was tested and evaluated inside a thermo-vacuum chamber and submitted to an as-orbit vacuum environment. In this study, the influence of temperature fields was neglected. This paper reports on the performance evaluation and discusses the results for this camera when operating within those mentioned test conditions. The overall optical tests and results show that the "in air" adjustment method was suitable to be performed, as a critical activity, to guarantee the equipment according to its design requirements.
NASA Technical Reports Server (NTRS)
Simon, F. F.
1975-01-01
The use of a solar simulator for performance determination permits collector testing under standard conditions of wind, ambient temperature, flow rate and sun. The performance results determined with the simulator have been found to be in good agreement with outdoor performance results. The measured thermal efficiency and evaluation of 23 collectors are reported which differ according to absorber material (copper, aluminum, steel), absorber coating (nonselective black paint, selective copper oxide, selective black nickel, selective black chrome), type of glazing material (glass, Tedlar, Lexan, antireflection glass), the use of honeycomb material and the use of vacuum to prevent thermal convection losses. The collectors were given performance rankings based on noon-hour solar conditions and all-day solar conditions. The determination with the simulator of an all-day collector performance was made possible by tests at different incident angles. The solar performance rankings were made based on whether the collector is to be used for pool heating, hot water, absorption air conditioning, heating, or for a solar Rankine machine.
Wolfe, Jace; Morais Duke, Mila; Schafer, Erin; Cire, George; Menapace, Christine; O'Neill, Lori
2016-01-01
The objective of this study was to evaluate the potential improvement in word recognition in quiet and in noise obtained with use of a Bluetooth-compatible wireless hearing assistance technology (HAT) relative to the acoustic mobile telephone condition (e.g. the mobile telephone receiver held to the microphone of the sound processor). A two-way repeated measures design was used to evaluate differences in telephone word recognition obtained in quiet and in competing noise in the acoustic mobile telephone condition compared to performance obtained with use of the CI sound processor and a telephone HAT. Sixteen adult users of Nucleus cochlear implants and the Nucleus 6 sound processor were included in this study. Word recognition over the mobile telephone in quiet and in noise was significantly better with use of the wireless HAT compared to performance in the acoustic mobile telephone condition. Word recognition over the mobile telephone was better in quiet when compared to performance in noise. The results of this study indicate that use of a wireless HAT improves word recognition over the mobile telephone in quiet and in noise relative to performance in the acoustic mobile telephone condition for a group of adult cochlear implant recipients.
40 CFR 86.1604 - Conditions for disapproval.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Altitude Performance Adjustments for New and In-Use Motor Vehicles and Engines § 86.1604 Conditions for disapproval. (a) The Administrator shall not approve altitude performance adjustments that will: (1) Cause any... engines, cause any reduction of vehicle performance (as evaluated by the manufacturer) such that vehicle...
Performance evaluation of Chrysopogon zizanoides under urban conditions of Kuwait.
Suleiman, Majda Khalil; Bhat, Narayana Ramachandra; Jacob, Sheena; Al-Burais, Meali
2018-02-01
Plant physiological and morphological attributes should be critically evaluated for selecting any species for landscaping projects. The selection of a species should be based on the evaluation of its adaptability, noninvasiveness, growth potential, and performance under the prevailing local arid conditions for their aesthetic looks, soil stabilization, and afforestation values. Chrysopogon zizanoides (Vetiver), is suitable for Kuwait because it can withstand fluctuating temperatures ranging from -14 to 55 °C with unique physical and physiological characteristics. Despite the successful growth performance of Vetiver in landscaping projects mostly in several tropical countries, it has not been utilized and evaluated in the Arabian Gulf region. The objective of the current study was to evaluate the performance of selected ten cultivars of Vetiver (ODV-1, 8, 9, 13, 17, 21, 23, Silent Valley, Urlikal, and Pannimedu) in the deficient soil and environmental conditions of Kuwait in urban landscape at minimal maintenance. It is suggested that based on visual greenery effect and overall growth performance cultivars, Pannimedu, Silent Valley, ODV-13, ODV-8 and ODV-9 can be considered for landscaping projects in Kuwait. To obtain the superior crown volume (which considers height and canopy) cultivar Pannimedu is suggested and to get a bushy growth (considering the number of tillers) cultivar ODV-13 and ODV-8 is found to be suitable.
Aluminum Lithium Alloy 2195 Fusion Welding Improvements with New Filler Wire
NASA Technical Reports Server (NTRS)
Russell, C.
2001-01-01
The objective of this research was to assess the B218 weld filler wire for Super Lightweight External Tank production, which could improve current production welding and repair productivity. We took the following approaches: (1) Perform a repair weld quick look evaluation between 4043/B218 and B218/B218 weld filler wire combinations and evaluation tensile properties for planished and unplanished conditions; and (2) Perform repair weld evaluation on structural simulation panel using 4043-B218 and B218/B218 weld filler wire combinations and evaluation tensile and simulated service fracture properties for planished and unplanished conditions.
Sisco, Howard; Leventhal, Gloria
2007-12-01
The importance of accurate performance appraisals is central to many aspects of personnel activities in organizations. This study examined threats due to past performance to accuracy of evaluation of subsequent performance by raters differing in scores on field dependence. 162 college students were classified as Field-dependent (n = 81) or Field-independent (n = 81), using a median split on the Group Embedded Figures Test. Past performance (a lecture) was good or poor, presented directly via a videotape or indirectly via a written evaluation to the Field-independent or Field-dependent groups. Analysis indicated the hypothesized contrast effect (ratings in the opposite direction from that of prior ratings) in the Direct condition and an unexpected, albeit smaller, contrast effect in the Indirect condition. There were also differential effects of performance, presentation, and field dependency on rating of lecturer's style and ability.
GICHD mine dog testing project : soil sample results #5.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnett, James L.; Phelan, James M.; Archuleta, Luisa M.
2004-01-01
A mine dog evaluation project initiated by the Geneva International Center for Humanitarian Demining is evaluating the capability and reliability of mine detection dogs. The performance of field-operational mine detection dogs will be measured in test minefields in Afghanistan containing actual, but unfused landmines. Repeated performance testing over two years through various seasonal weather conditions will provide data simulating near real world conditions. Soil samples will be obtained adjacent to the buried targets repeatedly over the course of the test. Chemical analysis results from these soil samples will be used to evaluate correlations between mine dog detection performance and seasonalmore » weather conditions. This report documents the analytical chemical methods and results from the fifth batch of soils received. This batch contained samples from Kharga, Afghanistan collected in June 2003.« less
Analysis of link performance for the FOENEX laser communications system
NASA Astrophysics Data System (ADS)
Juarez, Juan C.; Young, David W.; Venkat, Radha A.; Brown, David M.; Brown, Andrea M.; Oberc, Rachel L.; Sluz, Joseph E.; Pike, H. Alan; Stotts, Larry B.
2012-06-01
A series of experiments were conducted to validate the performance of the free-space optical communications (FSOC) subsystem under DARPA's FOENEX program. Over six days, bidirectional links at ranges of 10 and 17 km were characterized during different periods of the day to evaluate link performance. This paper will present the test configuration, evaluate performance of the FSOC subsystem against a variety of characterization approaches, and discuss the impact of the results, particularly with regards to the optical terminals. Finally, this paper will summarize the impact of turbulence conditions on the FSOC subsystem and present methods for estimating performance under different link distances and turbulence conditions.
CCTV Data Management for Effective Condition Assessment of Wastewater Collection Systems - slides
The project objectives are: Research current state of condition assessment technology for wastewater collection systems; Evaluate performance and cost of innovative and advanced infrastructure monitoring technologies; Identify and evaluate innovative CCTV technologies; and Prepar...
Testing & Evaluation of Close-Range SAR for Monitoring & Automatically Detecting Pavement Conditions
DOT National Transportation Integrated Search
2012-01-01
This report summarizes activities in support of the DOT contract on Testing & Evaluating Close-Range SAR for Monitoring & Automatically Detecting Pavement Conditions & Improve Visual Inspection Procedures. The work of this project was performed by Dr...
Weighting Mean and Variability during Confidence Judgments
de Gardelle, Vincent; Mamassian, Pascal
2015-01-01
Humans can not only perform some visual tasks with great precision, they can also judge how good they are in these tasks. However, it remains unclear how observers produce such metacognitive evaluations, and how these evaluations might be dissociated from the performance in the visual task. Here, we hypothesized that some stimulus variables could affect confidence judgments above and beyond their impact on performance. In a motion categorization task on moving dots, we manipulated the mean and the variance of the motion directions, to obtain a low-mean low-variance condition and a high-mean high-variance condition with matched performances. Critically, in terms of confidence, observers were not indifferent between these two conditions. Observers exhibited marked preferences, which were heterogeneous across individuals, but stable within each observer when assessed one week later. Thus, confidence and performance are dissociable and observers’ confidence judgments put different weights on the stimulus variables that limit performance. PMID:25793275
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adkins, Harold; Geelhood, Ken; Koeppel, Brian
2013-09-30
This document addresses Oak Ridge National Laboratory milestone M2FT-13OR0822015 Demonstration of Approach and Results on Used Nuclear Fuel Performance Characterization. This report provides results of the initial demonstration of the modeling capability developed to perform preliminary deterministic evaluations of moderate-to-high burnup used nuclear fuel (UNF) mechanical performance under normal conditions of storage (NCS) and normal conditions of transport (NCT) conditions. This report also provides results from the sensitivity studies that have been performed. Finally, discussion on the long-term goals and objectives of this initiative are provided.
ERIC Educational Resources Information Center
Gagne, Jean-Pierre; Laplante-Levesque, Ariane; Labelle, Maude; Doucet, Katrine; Potvin, Marie-Christine
2006-01-01
A program designed to evaluate the benefits of an audiovisual-frequency modulated (FM) system led to some questions concerning the effects of illumination level and a talker's skin color on speech-reading performance. To address those issues, the speech of a Caucasian female was videotaped under 2 conditions: a light skin color condition and a…
Performance, physiological, and oculometer evaluation of VTOL landing displays
NASA Technical Reports Server (NTRS)
North, R. A.; Stackhouse, S. P.; Graffunder, K.
1979-01-01
A methodological approach to measuring workload was investigated for evaluation of new concepts in VTOL aircraft displays. Physiological, visual response, and conventional flight performance measures were recorded for landing approaches performed in the NASA Visual Motion Simulator (VMS). Three displays (two computer graphic and a conventional flight director), three crosswind amplitudes, and two motion base conditions (fixed vs. moving base) were tested in a factorial design. Multivariate discriminant functions were formed from flight performance and/or visual response variables. The flight performance variable discriminant showed maximum differentation between crosswind conditions. The visual response measure discriminant maximized differences between fixed vs. motion base conditions and experimental displays. Physiological variables were used to attempt to predict the discriminant function values for each subject/condition trial. The weights of the physiological variables in these equations showed agreement with previous studies. High muscle tension, light but irregular breathing patterns, and higher heart rate with low amplitude all produced higher scores on this scale and thus represent higher workload levels.
A simulation evaluation of the engine monitoring and control system display
NASA Technical Reports Server (NTRS)
Abbott, Terence S.
1990-01-01
The Engine Monitoring and Control System (E-MACS) display is a new concept for an engine instrument display, the purpose of which is to provide an enhanced means for a pilot to control and monitor aircraft engine performance. It provides graphically-presented information about performance capabilities, current performance, and engine component or subsystem operational conditions relative to nominal conditions. The concept was evaluated by sixteen pilot-subjects against a traditional, state-of-the-art electronic engine display format. The results of this evaluation showed a substantial pilot preference for the E-MACS display relative to the traditional display. The results of the failure detection portion of the evaluation showed a 100 percent detection rate for the E-MACS display relative to a 57 percent rate for the traditional display. From these results, it is concluded that by providing this type of information in the cockpit, a reduction in pilot workload and an enhanced ability for detecting degraded or off-nominal conditions is probable, thus leading to an increase in operational safety.
An evaluation of GTAW-P versus GTA welding of alloy 718
NASA Technical Reports Server (NTRS)
Gamwell, W. R.; Kurgan, C.; Malone, T. W.
1991-01-01
Mechanical properties were evaluated to determine statistically whether the pulsed current gas tungsten arc welding (GTAW-P) process produces welds in alloy 718 with room temperature structural performance equivalent to current Space Shuttle Main Engine (SSME) welds manufactured by the constant current GTAW-P process. Evaluations were conducted on two base metal lots, two filler metal lots, two heat input levels, and two welding processes. The material form was 0.125-inch (3.175-mm) alloy 718 sheet. Prior to welding, sheets were treated to either the ST or STA-1 condition. After welding, panels were left as welded or heat treated to the STA-1 condition, and weld beads were left intact or machined flush. Statistical analyses were performed on yield strength, ultimate tensile strength (UTS), and high cycle fatigue (HCF) properties for all the post welded material conditions. Analyses of variance were performed on the data to determine if there were any significant effects on UTS or HCF life due to variations in base metal, filler metal, heat input level, or welding process. Statistical analyses showed that the GTAW-P process does produce welds with room temperature structural performance equivalent to current SSME welds manufactured by the GTAW process, regardless of prior material condition or post welding condition.
The report gives results of a study in which NOx emissions and general combustion performance characteristics of four burners were evaluated under experimental furnace conditions. Of primary interest was the performance of a low NOx Distributed Mixing Burner (DMB), which was test...
Continued Evaluation of Gear Condition Indicator Performance on Rotorcraft Fleet
NASA Technical Reports Server (NTRS)
Delgado, Irebert R.; Dempsey, Paula J.; Antolick, Lance J.; Wade, Daniel R.
2013-01-01
This paper details analyses of condition indicator performance for the helicopter nose gearbox within the U.S. Army's Condition-Based Maintenance Program. Ten nose gearbox data sets underwent two specific analyses. A mean condition indicator level analysis was performed where condition indicator performance was based on a 'batting average' measured before and after part replacement. Two specific condition indicators, Diagnostic Algorithm 1 and Sideband Index, were found to perform well for the data sets studied. A condition indicator versus gear wear analysis was also performed, where gear wear photographs and descriptions from Army tear-down analyses were categorized based on ANSI/AGMA 1010-E95 standards. Seven nose gearbox data sets were analyzed and correlated with condition indicators Diagnostic Algorithm 1 and Sideband Index. Both were found to be most responsive to gear wear cases of micropitting and spalling. Input pinion nose gear box condition indicators were found to be more responsive to part replacement during overhaul than their corresponding output gear nose gear box condition indicators.
NASA Technical Reports Server (NTRS)
Frost, Chad R.; Franklin, James A.; Hardy, Gordon H.
2002-01-01
A piloted simulation was performed on the Vertical Motion Simulator at NASA Ames Research Center to evaluate flying qualities of a tilt-wing Short Take-Off and Landing (STOL) transport aircraft during final approach and landing. The experiment was conducted to assess the design s handling qualities, and to evaluate the use of flightpath-centered guidance for the precision approach and landing tasks required to perform STOL operations in instrument meteorological conditions, turbulence, and wind. Pilots rated the handling qualities to be satisfactory for all operations evaluated except those encountering extreme crosswinds and severe windshear; even in these difficult meteorological conditions, adequate handling qualities were maintained. The advanced flight control laws and guidance displays provided consistent performance and precision landings.
Fuzzy logic based sensor performance evaluation of vehicle mounted metal detector systems
NASA Astrophysics Data System (ADS)
Abeynayake, Canicious; Tran, Minh D.
2015-05-01
Vehicle Mounted Metal Detector (VMMD) systems are widely used for detection of threat objects in humanitarian demining and military route clearance scenarios. Due to the diverse nature of such operational conditions, operational use of VMMD without a proper understanding of its capability boundaries may lead to heavy causalities. Multi-criteria fitness evaluations are crucial for determining capability boundaries of any sensor-based demining equipment. Evaluation of sensor based military equipment is a multi-disciplinary topic combining the efforts of researchers, operators, managers and commanders having different professional backgrounds and knowledge profiles. Information acquired through field tests usually involves uncertainty, vagueness and imprecision due to variations in test and evaluation conditions during a single test or series of tests. This report presents a fuzzy logic based methodology for experimental data analysis and performance evaluation of VMMD. This data evaluation methodology has been developed to evaluate sensor performance by consolidating expert knowledge with experimental data. A case study is presented by implementing the proposed data analysis framework in a VMMD evaluation scenario. The results of this analysis confirm accuracy, practicability and reliability of the fuzzy logic based sensor performance evaluation framework.
Underground coal mine instrumentation and test
NASA Technical Reports Server (NTRS)
Burchill, R. F.; Waldron, W. D.
1976-01-01
The need to evaluate mechanical performance of mine tools and to obtain test performance data from candidate systems dictate that an engineering data recording system be built. Because of the wide range of test parameters which would be evaluated, a general purpose data gathering system was designed and assembled to permit maximum versatility. A primary objective of this program was to provide a specific operating evaluation of a longwall mining machine vibration response under normal operating conditions. A number of mines were visited and a candidate for test evaluation was selected, based upon management cooperation, machine suitability, and mine conditions. Actual mine testing took place in a West Virginia mine.
Veterinary and human vaccine evaluation methods
Knight-Jones, T. J. D.; Edmond, K.; Gubbins, S.; Paton, D. J.
2014-01-01
Despite the universal importance of vaccines, approaches to human and veterinary vaccine evaluation differ markedly. For human vaccines, vaccine efficacy is the proportion of vaccinated individuals protected by the vaccine against a defined outcome under ideal conditions, whereas for veterinary vaccines the term is used for a range of measures of vaccine protection. The evaluation of vaccine effectiveness, vaccine protection assessed under routine programme conditions, is largely limited to human vaccines. Challenge studies under controlled conditions and sero-conversion studies are widely used when evaluating veterinary vaccines, whereas human vaccines are generally evaluated in terms of protection against natural challenge assessed in trials or post-marketing observational studies. Although challenge studies provide a standardized platform on which to compare different vaccines, they do not capture the variation that occurs under field conditions. Field studies of vaccine effectiveness are needed to assess the performance of a vaccination programme. However, if vaccination is performed without central co-ordination, as is often the case for veterinary vaccines, evaluation will be limited. This paper reviews approaches to veterinary vaccine evaluation in comparison to evaluation methods used for human vaccines. Foot-and-mouth disease has been used to illustrate the veterinary approach. Recommendations are made for standardization of terminology and for rigorous evaluation of veterinary vaccines. PMID:24741009
NASA Astrophysics Data System (ADS)
Quintana, Oscar A.; Tong, Weidong
2017-12-01
We investigated the selective laser melting (SLM) process for development of Ti-6Al-4 V solid material with oxygen content corresponding to the extra low interstitial (ELI) and non-ELI conditions. The microstructure, chemistry, and tensile properties of samples in as-built and hot isostatically pressed (HIPed) condition were evaluated for both material types, while fatigue performance was evaluated by rotating bending fatigue tests on both smooth and notched SLM ELI and non-ELI Ti-6Al-4 V samples in HIPed condition.
Mioni, Giovanna; Bertucci, Erica; Rosato, Antonella; Terrett, Gill; Rendell, Peter G; Zamuner, Massimo; Stablum, Franca
2017-06-01
Previous studies have shown that traumatic brain injury (TBI) patients have difficulties with prospective memory (PM). Considering that PM is closely linked to independent living it is of primary interest to develop strategies that can improve PM performance in TBI patients. This study employed Virtual Week task as a measure of PM, and we included future event simulation to boost PM performance. Study 1 evaluated the efficacy of the strategy and investigated possible practice effects. Twenty-four healthy participants performed Virtual Week in a no strategy condition, and 24 healthy participants performed it in a mixed condition (no strategy - future event simulation). In Study 2, 18 TBI patients completed the mixed condition of Virtual Week and were compared with the 24 healthy controls who undertook the mixed condition of Virtual Week in Study 1. All participants also completed a neuropsychological evaluation to characterize the groups on level of cognitive functioning. Study 1 showed that participants in the future event simulation condition outperformed participants in the no strategy condition, and these results were not attributable to practice effects. Results of Study 2 showed that TBI patients performed PM tasks less accurately than controls, but that future event simulation can substantially reduce TBI-related deficits in PM performance. The future event simulation strategy also improved the controls' PM performance. These studies showed the value of future event simulation strategy in improving PM performance in healthy participants as well as in TBI patients. TBI patients performed PM tasks less accurately than controls, confirming prospective memory impairment in these patients. Participants in the future event simulation condition out-performed participants in the no strategy condition. Future event simulation can substantially reduce TBI-related deficits in PM performance. Future event simulation strategy also improved the controls' PM performance. © 2017 The British Psychological Society.
Test and evaluation of the HIDEC engine uptrim algorithm
NASA Technical Reports Server (NTRS)
Ray, R. J.; Myers, L. P.
1986-01-01
The highly integrated digital electronic control (HIDEC) program will demonstrate and evaluate the improvements in performance and mission effectiveness that result from integrated engine-airframe control systems. Performance improvements will result from an adaptive engine stall margin mode, a highly integrated mode that uses the airplane flight conditions and the resulting inlet distortion to continuously compute engine stall margin. When there is excessive stall margin, the engine is uptrimmed for more thrust by increasing engine pressure ratio (EPR). The EPR uptrim logic has been evaluated and implemented into computer simulations. Thrust improvements over 10 percent are predicted for subsonic flight conditions. The EPR uptrim was successfully demonstrated during engine ground tests. Test results verify model predictions at the conditions tested.
Balanced RAP/RAS mix design and performance evaluation for project - specific service conditions.
DOT National Transportation Integrated Search
2013-01-01
This presentation summarizes Projects 0-6092/0-6614. It includes accomplishments, best practices, field performance data of RAP/RAS test sections, balanced RAP/RAS mix design for project-specific conditions, and approaches for improving RAP/RAS mix p...
Evaluation of several non-reflecting computational boundary conditions for duct acoustics
NASA Technical Reports Server (NTRS)
Watson, Willie R.; Zorumski, William E.; Hodge, Steve L.
1994-01-01
Several non-reflecting computational boundary conditions that meet certain criteria and have potential applications to duct acoustics are evaluated for their effectiveness. The same interior solution scheme, grid, and order of approximation are used to evaluate each condition. Sparse matrix solution techniques are applied to solve the matrix equation resulting from the discretization. Modal series solutions for the sound attenuation in an infinite duct are used to evaluate the accuracy of each non-reflecting boundary conditions. The evaluations are performed for sound propagation in a softwall duct, for several sources, sound frequencies, and duct lengths. It is shown that a recently developed nonlocal boundary condition leads to sound attenuation predictions considerably more accurate for short ducts. This leads to a substantial reduction in the number of grid points when compared to other non-reflecting conditions.
NASA Astrophysics Data System (ADS)
Jeon, Juncheol; Han, Chulhee; Chung, Jye Ung; Choi, Seung-Bok
2015-01-01
In this paper, a novel single-stage valve system activated by a piezostack actuator is proposed and experimentally evaluated at both room temperature (20 °C) and high temperature (100 °C) conditions. A hinge-lever displacement amplifier is adopted in the valve system to magnify the displacement generated from the piezostack actuator. After explaining the operating principle of the proposed piezostack-driven single-stage valve system, the geometric dimensions and mechanical properties of the valve components are discussed in details. An experimental apparatus is then manufactured to evaluate the performances of the valve system such as flow rate. The experimental apparatus consists of a heat chamber, which can regulate the temperature of the valve system and oil, pneumatic-hydraulic cylinders, a hydraulic circuit, a pneumatic circuit, electronic devices, an interface card, and a high voltage amplifier. The pneumatic-hydraulic cylinder transforms the pneumatic pressure into hydraulic pressure. The performances of the valve system regarding spool response, pressure drop, and flow rate are evaluated and presented. In addition, the performance of the valve system under high temperature condition is compared with that under room temperature condition. The experimental results are plotted in both frequency and time domains.
Evaluation of ventilators used during transport of critically ill patients: a bench study.
Boussen, Salah; Gainnier, Marc; Michelet, Pierre
2013-11-01
To evaluate the most recent transport ventilators' operational performance regarding volume delivery in controlled mode, trigger function, and the quality of pressurization in pressure support mode. Eight recent transport ventilators were included in a bench study in order to evaluate their accuracy to deliver a set tidal volume under normal resistance and compliance conditions, ARDS conditions, and obstructive conditions. The performance of the triggering system was assessed by the measure of the decrease in pressure and the time delay required to open the inspiratory valve. The quality of pressurization was obtained by computing the integral of the pressure-time curve for the first 300 ms and 500 ms after the onset of inspiration. For the targeted tidal volumes of 300, 500, and 800 mL the errors ranged from -3% to 48%, -7% to 18%, and -5% to 25% in the normal conditions, -4% to 27%, -2% to 35%, and -3% to 35% in the ARDS conditions, and -4% to 53%, -6% to 30%, and -30% to 28% in the obstructive conditions. In pressure support mode the pressure drop range was 0.4-1.7 cm H2O, the trigger delay range was 68-198 ms, and the pressurization performance (percent of ideal pressurization, as measured by pressure-time product at 300 ms and 500 ms) ranges were -9% to 44% at 300 ms and 6%-66% at 500 ms (P < .01). There were important differences in the performance of the tested ventilators. The most recent turbine ventilators outperformed the pneumatic ventilators. The best performers among the turbine ventilators proved comparable to modern ICU ventilators.
Development and evaluation of endurance test system for ventricular assist devices.
Sumikura, Hirohito; Homma, Akihiko; Ohnuma, Kentaro; Taenaka, Yoshiyuki; Takewa, Yoshiaki; Mukaibayashi, Hiroshi; Katano, Kazuo; Tatsumi, Eisuke
2013-06-01
We developed a novel endurance test system that can arbitrarily set various circulatory conditions and has durability and stability for long-term continuous evaluation of ventricular assist devices (VADs), and we evaluated its fundamental performance and prolonged durability and stability. The circulation circuit of the present endurance test system consisted of a pulsatile pump with a small closed chamber (SCC), a closed chamber, a reservoir and an electromagnetic proportional valve. Two duckbill valves were mounted in the inlet and outlet of the pulsatile pump. The features of the circulation circuit are as follows: (1) the components of the circulation circuit consist of optimized industrial devices, giving durability; (2) the pulsatile pump can change the heart rate and stroke length (SL), as well as its compliance using the SCC. Therefore, the endurance test system can quantitatively reproduce various circulatory conditions. The range of reproducible circulatory conditions in the endurance test circuit was examined in terms of fundamental performance. Additionally, continuous operation for 6 months was performed in order to evaluate the durability and stability. The circulation circuit was able to set up a wide range of pressure and total flow conditions using the SCC and adjusting the pulsatile pump SL. The long-term continuous operation test demonstrated that stable, continuous operation for 6 months was possible without leakage or industrial device failure. The newly developed endurance test system demonstrated a wide range of reproducible circulatory conditions, durability and stability, and is a promising approach for evaluating the basic characteristics of VADs.
DOT National Transportation Integrated Search
2010-10-01
This research study evaluated the performance of various pavement preservation treatments over time and under different : environmental conditions to quantify the economics of each treatment type. There are three primary techniques utilized in Colora...
Drovetskaya, T V; Kreeger, R L; Amos, J L; Davis, C B; Zhou, S
2004-01-01
A new class of cationic conditioning polymers (Polymer SL) has been prepared and evaluated in shampoo formulations. Polymer SL is a family of high viscosity quaternized hydroxyethyl cellulose (HEC) polymers with cationic substitution of trimethyl ammonium and dimethyldodecyl ammonium (Figure 1). SL compositions benefit from hydrophobic character to deliver superior conditioning performance in hair care applications. At the same time, low levels of hydrophobes have been chosen to assure good compatibility with surfactant systems without the complications of associative thickening. The polymers have been evaluated in clear shampoo formulations and two-in-one silicone containing shampoos using objective lab methods and subjective panel evaluation on hair tresses. Commercial conditioning polymers: Polyquaternium-10 (PQ-10) (UCARE Polymer LR-30M) and Guar Hydroxypro-pyltrimethylammonium Chloride (Jaguar C-13S) were used as performance benchmarks. The new hydrophobically-modified cationic polymers demonstrated superior performance in all major categories of conditioning and showed improved silicone deposition from two-in-one systems. Moreover, they retained other good qualities of their PQ-10 structural analogs such as enabling crystal clear formulations and showing no build-up or volume-down effects on hair. These new olymers were also found to be efficient conditioning agents in different surfactant systems with or without silicones.
DOT National Transportation Integrated Search
2013-04-01
Two microwave-based systems for vehicle detection (by Wavetronix and MS SEDCO) were evaluated at stop bar and : advance zones of a signalized intersection under three adverse weather conditions: (1) wind, (2) snow-covered roadway, : and (3) rain. Wea...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shrestha, Som S; Vineyard, Edward Allan; Mumpower, Kevin
In response to environmental concerns raised by the use of refrigerants with high Global Warming Potential (GWP), the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) has launched an industry-wide cooperative research program, referred to as the Low-GWP Alternative Refrigerants Evaluation Program (AREP), to identify and evaluate promising alternative refrigerants for major product categories. After successfully completing the first phase of the program in December 2013, AHRI launched a second phase of the Low-GWP AREP in 2014 to continue research in areas that were not previously addressed, including refrigerants in high ambient conditions, refrigerants in applications not tested in the first phase,more » and new refrigerants identified since testing for the program began. Although the Ozone Depletion Potential of R-410A is zero, this refrigerant is under scrutiny due to its high GWP. Several candidate alternative refrigerants have already demonstrated low global warming potential. Performance of these low-GWP alternative refrigerants is being evaluated for Air conditioning and heat pump applications to ensure acceptable system capacity and efficiency. This paper reports the results of a series of compressor calorimeter tests conducted for the second phase of the AREP to evaluate the performance of R-410A alternative refrigerants in a reciprocating compressor designed for air conditioning systems. It compares performance of alternative refrigerants ARM-71A, L41-1, DR-5A, D2Y-60, and R-32 to that of R-410A over a wide range of operating conditions. The tests showed that, in general, cooling capacities were slightly lower (except for the R-32), but energy efficiency ratios (EER) of the alternative refrigerants were comparable to that of R-410A.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2014-10-01
In this project, Building America team IBACOS performed field testing in a new construction unoccupied test house in Pittsburgh, Pennsylvania, to evaluate heating, ventilating, and air conditioning (HVAC) distribution systems during heating, cooling, and midseason conditions. The team evaluated a market-available through-wall air transfer fan system that provides air to the bedrooms.The relative ability of this system was considered with respect to relevant Air Conditioning Contractors of America and ASHRAE standards for house temperature uniformity and stability.
Potential Evaluation of Solar Heat Assisted Desiccant Hybrid Air Conditioning System
NASA Astrophysics Data System (ADS)
Tran, Thien Nha; Hamamoto, Yoshinori; Akisawa, Atsushi; Kashiwagi, Takao
The solar thermal driven desiccant dehumidification-absorption cooling hybrid system has superior advantage in hot-humid climate regions. The reasonable air processing of desiccant hybrid air conditioning system and the utility of clean and free energy make the system environment friendly and energy efficient. The study investigates the performance of the desiccant dehumidification air conditioning systems with solar thermal assistant. The investigation is performed for three cases which are combinations of solar thermal and absorption cooling systems with different heat supply temperature levels. Two solar thermal systems are used in the study: the flat plate collector (FPC) and the vacuum tube with compound parabolic concentrator (CPC). The single-effect and high energy efficient double-, triple-effect LiBr-water absorption cooling cycles are considered for cooling systems. COP of desiccant hybrid air conditioning systems are determined. The evaluation of these systems is subsequently performed. The single effect absorption cooling cycle combined with the flat plate collector solar system is found to be the most energy efficient air conditioning system.
DOT National Transportation Integrated Search
1996-01-01
Reports the results of a part-task simulation evaluating the separate and combined effects of an electronic moving map display and newly developed HUD symbology on ground taxi performance, under moderate- and low-visibility conditions. Twenty-four co...
NASA Technical Reports Server (NTRS)
Ray, R. J.; Myers, L. P.
1986-01-01
The highly integrated digital electronic control (HIDEC) program will demonstrate and evaluate the improvements in performance and mission effectiveness that result from integrated engine-airframe control systems. Performance improvements will result from an adaptive engine stall margin mode, a highly integrated mode that uses the airplane flight conditions and the resulting inlet distortion to continuously compute engine stall margin. When there is excessive stall margin, the engine is uptrimmed for more thrust by increasing engine pressure ratio (EPR). The EPR uptrim logic has been evaluated and implemente into computer simulations. Thrust improvements over 10 percent are predicted for subsonic flight conditions. The EPR uptrim was successfully demonstrated during engine ground tests. Test results verify model predictions at the conditions tested.
Performance Evaluation of Particle Sampling Probes for Emission Measurements of Aircraft Jet Engines
NASA Technical Reports Server (NTRS)
Lee, Poshin; Chen, Da-Ren; Sanders, Terry (Technical Monitor)
2001-01-01
Considerable attention has been recently received on the impact of aircraft-produced aerosols upon the global climate. Sampling particles directly from jet engines has been performed by different research groups in the U.S. and Europe. However, a large variation has been observed among published data on the conversion efficiency and emission indexes of jet engines. The variation results surely from the differences in test engine types, engine operation conditions, and environmental conditions. The other factor that could result in the observed variation is the performance of sampling probes used. Unfortunately, it is often neglected in the jet engine community. Particle losses during the sampling, transport, and dilution processes are often not discussed/considered in literatures. To address this issue, we evaluated the performance of one sampling probe by challenging it with monodisperse particles. A significant performance difference was observed on the sampling probe evaluated under different temperature conditions. Thermophoretic effect, nonisokinetic sampling and turbulence loss contribute to the loss of particles in sampling probes. The results of this study show that particle loss can be dramatic if the sampling probe is not well designed. Further, the result allows ones to recover the actual size distributions emitted from jet engines.
Tian, Tengxiang; Feng, Xue; Gu, Ruolei; Broster, Lucas S; Feng, Chunliang; Wang, Lili; Guan, Qing; Luo, Yue-Jia
2015-07-30
The audience effect refers to the phenomenon that one׳s performance on a task is affected by the presence of others. Here we investigated how the audience effect modulates the neurocognitive signatures underlying people׳s evaluation of their own task performance/outcome. Participants in our study played a gambling game in two social contexts: an "audience" condition and an "alone" condition. The presence of others modulated the feedback-related negativity (FRN), which might reflect enhanced motivational significance or increased reward processing when participants were watched compared to when they were alone. We also observed increased P300 responses to outcome feedback in the audience condition, presumably reflecting more elaborative and sustained evaluation of outcomes in the audience than alone context. This audience effect on the evaluative processes complements previous observations on the social nature of outcome evaluation and extends a traditional topic in social psychology to the neuroscientific field. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Wu, Linqin; Xu, Sheng; Jiang, Dezhi
2015-12-01
Industrial wireless networked control system has been widely used, and how to evaluate the performance of the wireless network is of great significance. In this paper, considering the shortcoming of the existing performance evaluation methods, a comprehensive performance evaluation method of networks multi-indexes fuzzy analytic hierarchy process (MFAHP) combined with the fuzzy mathematics and the traditional analytic hierarchy process (AHP) is presented. The method can overcome that the performance evaluation is not comprehensive and subjective. Experiments show that the method can reflect the network performance of real condition. It has direct guiding role on protocol selection, network cabling, and node setting, and can meet the requirements of different occasions by modifying the underlying parameters.
Electro-optics laboratory evaluation: Deutsch optical waveguide connectors
NASA Technical Reports Server (NTRS)
1980-01-01
A description of a test program evaluating the performance of an optical waveguide connector system is presented. Both quality and effectiveness of connections made in an optical fiber, performance of the equipment used and applicability of equipment and components to field conditions are reviewed.
ERIC Educational Resources Information Center
Meyer, Calvin F.; Benson, Robert T.
This guide provides job relevant tasks, performance objectives, performance guides, resources, learning activitites, evaluation standards, and achievement testing in the occupation of environmental control system installer/servicer (residential air conditioning mechanic). It is designed to be used with any chosen teaching method. The course…
Chemical boundary conditions are a key input to regional-scale photochemical models. In this study, performed during the third phase of the Air Quality Model Evaluation International Initiative (AQMEII3), we perform annual simulations over North America with chemical boundary con...
The effects of arousal reappraisal on stress responses, performance and attention.
Sammy, Nadine; Anstiss, Paul A; Moore, Lee J; Freeman, Paul; Wilson, Mark R; Vine, Samuel J
2017-11-01
This study examined the effects of arousal reappraisal on cardiovascular responses, demand and resource evaluations, self-confidence, performance and attention under pressurized conditions. A recent study by Moore et al. [2015. Reappraising threat: How to optimize performance under pressure. Journal of Sport and Exercise Psychology, 37(3), 339-343. doi: 10.1123/jsep.2014-0186 ] suggested that arousal reappraisal is beneficial to the promotion of challenge states and leads to improvements in single-trial performance. This study aimed to further the work of Moore and colleagues (2015) by examining the effects of arousal reappraisal on cardiovascular responses, demand and resource evaluations, self-confidence, performance and attention in a multi-trial pressurized performance situation. Participants were randomly assigned to either an arousal reappraisal intervention or control condition, and completed a pressurized dart throwing task. The intervention encouraged participants to view their physiological arousal as facilitative rather than debilitative to performance. Measures of cardiovascular reactivity, demand and resource evaluations, self-confidence, task performance and attention were recorded. The reappraisal group displayed more favorable cardiovascular reactivity and reported higher resource evaluations and higher self-confidence than the control group but no task performance or attention effects were detected. These findings demonstrate the strength of arousal reappraisal in promoting adaptive stress responses, perceptions of resources and self-confidence.
Battery testing at Argonne National Laboratory
NASA Astrophysics Data System (ADS)
Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.
Advanced battery technology evaluations are performed under simulated electric-vehicle operating conditions at the Analysis & Diagnostic Laboratory (ADL) of Argonne National Laboratory. The ADL results provide insight into those factors that limit battery performance and life. The ADL facilities include a test laboratory to conduct battery experimental evaluations under simulated application conditions and a post-test analysis laboratory to determine, in a protected atmosphere if needed, component compositional changes and failure mechanisms. This paper summarizes the performance characterizations and life evaluations conducted during FY-92 on both single cells and multi-cell modules that encompass six battery technologies (Na/S, Li/FeS, Ni/Metal-Hydride, Ni/Zn, Ni/Cd, Ni/Fe). These evaluations were performed for the Department of Energy, Office of Transportation Technologies, Electric and Hybrid Propulsion Division, and the Electric Power Research Institute. The ADL provides a common basis for battery performance characterization and life evaluations with unbiased application of tests and analyses. The results help identify the most promising R&D approaches for overcoming battery limitations, and provide battery users, developers, and program managers with a measure of the progress being made in battery R&D programs, a comparison of battery technologies, and basic data for modeling.
The Effect of Conductor Expressivity on Ensemble Performance Evaluation
ERIC Educational Resources Information Center
Morrison, Steven J.; Price, Harry E.; Geiger, Carla G.; Cornacchio, Rachel A.
2009-01-01
In this study, the authors examined whether a conductor's use of high-expressivity or low-expressivity techniques affected evaluations of ensemble performances that were identical across conducting conditions. Two conductors each conducted two 1-minute parallel excerpts from Percy Grainger's "Walking Tune." Each directed one excerpt…
DOT National Transportation Integrated Search
2008-05-01
The performance of three Video Detection Systems (VDS), namely Autoscope, Iteris, and Peek, was evaluated : at stop bar and advance locations, at an instrumented signalized intersection located in Rantoul, Illinois, utilizing : a side-by-side install...
Results of advanced battery technology evaluations for electric vehicle applications
NASA Astrophysics Data System (ADS)
Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.
1992-10-01
Advanced battery technology evaluations are performed under simulated electric-vehicle operating conditions at the Analysis and Diagnostic Laboratory (ADL) of Argonne National Laboratory. The ADL results provide insight into those factors that limit battery performance and life. The ADL facilities include a test laboratory to conduct battery experimental evaluations under simulated application conditions and a post-test analysis laboratory to determine, in a protected atmosphere if needed, component compositional changes and failure mechanisms. This paper summarizes the performance characterizations and life evaluations conducted during 1991-1992 on both single cells and multi-cell modules that encompass eight battery technologies (Na/S, Li/MS (M=metal), Ni/MH, Ni/Cd, Ni/Zn, Ni/Fe, Zn/Br, and Pb-acid). These evaluations were performed for the Department of Energy, Office of Transportation Technologies, Electric and Hybrid Propulsion Division, and the Electric Power Research Institute. The ADL provides a common basis for battery performance characterization and life evaluations with unbiased application of tests and analyses. The results help identify the most-promising R&D approaches for overcoming battery limitations, and provide battery users, developers, and program managers with a measure of the progress being made in battery R&D programs, a comparison of battery technologies, and basic data for modeling.
A strategy for evaluating pathway analysis methods.
Yu, Chenggang; Woo, Hyung Jun; Yu, Xueping; Oyama, Tatsuya; Wallqvist, Anders; Reifman, Jaques
2017-10-13
Researchers have previously developed a multitude of methods designed to identify biological pathways associated with specific clinical or experimental conditions of interest, with the aim of facilitating biological interpretation of high-throughput data. Before practically applying such pathway analysis (PA) methods, we must first evaluate their performance and reliability, using datasets where the pathways perturbed by the conditions of interest have been well characterized in advance. However, such 'ground truths' (or gold standards) are often unavailable. Furthermore, previous evaluation strategies that have focused on defining 'true answers' are unable to systematically and objectively assess PA methods under a wide range of conditions. In this work, we propose a novel strategy for evaluating PA methods independently of any gold standard, either established or assumed. The strategy involves the use of two mutually complementary metrics, recall and discrimination. Recall measures the consistency of the perturbed pathways identified by applying a particular analysis method to an original large dataset and those identified by the same method to a sub-dataset of the original dataset. In contrast, discrimination measures specificity-the degree to which the perturbed pathways identified by a particular method to a dataset from one experiment differ from those identifying by the same method to a dataset from a different experiment. We used these metrics and 24 datasets to evaluate six widely used PA methods. The results highlighted the common challenge in reliably identifying significant pathways from small datasets. Importantly, we confirmed the effectiveness of our proposed dual-metric strategy by showing that previous comparative studies corroborate the performance evaluations of the six methods obtained by our strategy. Unlike any previously proposed strategy for evaluating the performance of PA methods, our dual-metric strategy does not rely on any ground truth, either established or assumed, of the pathways perturbed by a specific clinical or experimental condition. As such, our strategy allows researchers to systematically and objectively evaluate pathway analysis methods by employing any number of datasets for a variety of conditions.
NASA Technical Reports Server (NTRS)
1981-01-01
The Sunmaster DEC 8A Large Manifold solar collector using simulated conditions was evaluated. The collector provided 17.17 square feet of gross collector area. Test conditions, test requirements, an analysis of results, and tables of test data are reported.
49 CFR 236.909 - Minimum performance standard.
Code of Federal Regulations, 2013 CFR
2013-10-01
... product will not result in risk that exceeds the previous condition. The railroad shall determine, prior... product will not result in risk that exceeds the previous condition. In evaluating the sufficiency of the... factors pertinent to evaluation of risk assessments, listed in § 236.913(g)(2). (c) What is the scope of a...
49 CFR 236.909 - Minimum performance standard.
Code of Federal Regulations, 2014 CFR
2014-10-01
... product will not result in risk that exceeds the previous condition. The railroad shall determine, prior... product will not result in risk that exceeds the previous condition. In evaluating the sufficiency of the... factors pertinent to evaluation of risk assessments, listed in § 236.913(g)(2). (c) What is the scope of a...
49 CFR 236.909 - Minimum performance standard.
Code of Federal Regulations, 2012 CFR
2012-10-01
... product will not result in risk that exceeds the previous condition. The railroad shall determine, prior... product will not result in risk that exceeds the previous condition. In evaluating the sufficiency of the... factors pertinent to evaluation of risk assessments, listed in § 236.913(g)(2). (c) What is the scope of a...
49 CFR 236.909 - Minimum performance standard.
Code of Federal Regulations, 2011 CFR
2011-10-01
... product will not result in risk that exceeds the previous condition. The railroad shall determine, prior... product will not result in risk that exceeds the previous condition. In evaluating the sufficiency of the... factors pertinent to evaluation of risk assessments, listed in § 236.913(g)(2). (c) What is the scope of a...
Ehrhardt, Matthew J; Sandlund, John T; Zhang, Nan; Liu, Wei; Ness, Kirsten K; Bhakta, Nickhill; Chemaitilly, Wassim; Krull, Kevin R; Brinkman, Tara M; Crom, Deborah B; Kun, Larry; Kaste, Sue C; Armstrong, Gregory T; Green, Daniel M; Srivastava, Kumar; Robison, Leslie L; Hudson, Melissa M; Mulrooney, Daniel A
2017-06-01
Survivors of childhood non-Hodgkin lymphoma (NHL) are at increased risk for chronic health conditions. The objective of this study was to characterize health conditions, neurocognitive function, and physical performance among a clinically evaluated cohort of 200 childhood NHL survivors. Chronic health and neurocognitive conditions were graded as per a modified version of the National Cancer Institute Common Terminology Criteria for Adverse Events (CTCAE) and impaired physical function defined as performance < 10th percentile of normative data. Multivariable regression was used to investigate associations between sociodemographic characteristics, therapeutic exposures, and outcomes. Survivors were a median age of 10 years (range 1-19) at diagnosis and 34 years (range 20-58) at evaluation. Eighty-eight (44%) received radiation, 46 (23%) cranial radiation, and 69 (35%) high-dose methotrexate. Most prevalent CTCAE Grades 3-4 (severe life-threatening) conditions were obesity (35%), hypertension (9%), and impairment of executive function (13%), attention (9%), and memory (4%). Many had impaired strength (48%), flexibility (39%), muscular endurance (36%), and mobility (36%). Demographic and treatment-related factors were associated with the development of individual chronic diseases and functional deficits. Clinical evaluation identified a high prevalence of chronic health conditions, neurocognitive deficits, and performance limitations in childhood NHL survivors. © 2016 Wiley Periodicals, Inc.
ERIC Educational Resources Information Center
Desombre, Caroline; Anegmar, Souad; Delelis, Gérald
2018-01-01
This study investigated the hypothesis that cognitive performance of students with physical disabilities may be influenced by the evaluators' identity. Students with or without a physical disability completed a logic test and were informed that they would be evaluated by students from their own group (ingroup condition) or from an other group…
Dedovic, Katarina; Renwick, Robert; Mahani, Najmeh Khalili; Engert, Veronika; Lupien, Sonia J.; Pruessner, Jens C.
2005-01-01
Objective We developed a protocol for inducing moderate psychologic stress in a functional imaging setting and evaluated the effects of stress on physiology and brain activation. Methods The Montreal Imaging Stress Task (MIST), derived from the Trier Mental Challenge Test, consists of a series of computerized mental arithmetic challenges, along with social evaluative threat components that are built into the program or presented by the investigator. To allow the effects of stress and mental arithmetic to be investigated separately, the MIST has 3 test conditions (rest, control and experimental), which can be presented in either a block or an event-related design, for use with functional magnetic resonance imaging (fMRI) or positron emission tomography (PET). In the rest condition, subjects look at a static computer screen on which no tasks are shown. In the control condition, a series of mental arithmetic tasks are displayed on the computer screen, and subjects submit their answers by means of a response interface. In the experimental condition, the difficulty and time limit of the tasks are manipulated to be just beyond the individual's mental capacity. In addition, in this condition the presentation of the mental arithmetic tasks is supplemented by a display of information on individual and average performance, as well as expected performance. Upon completion of each task, the program presents a performance evaluation to further increase the social evaluative threat of the situation. Results In 2 independent studies using PET and a third independent study using fMRI, with a total of 42 subjects, levels of salivary free cortisol for the whole group were significantly increased under the experimental condition, relative to the control and rest conditions. Performing mental arithmetic was linked to activation of motor and visual association cortices, as well as brain structures involved in the performance of these tasks (e.g., the angular gyrus). Conclusions We propose the MIST as a tool for investigating the effects of perceiving and processing psychosocial stress in functional imaging studies. PMID:16151536
The effects of competition on achievement motivation in Chinese classrooms.
Lam, Shui-fong; Yim, Pui-shan; Law, Josephine S F; Cheung, Rebecca W Y
2004-06-01
Laboratory studies have consistently found that competition induces performance goals and affects learning motivation. However, the ecological validity of these results is yet to be established. There is a need for investigation of whether the results hold in both the classroom context and non-Western culture. The study investigated the effects of competition on learning motivation among Chinese students in an authentic classroom setting. The participants were 52 students of grade 7 from two Hong Kong secondary schools. They were randomly assigned to either competitive or non-competitive conditions in a 2-hour Chinese typewriting course. Students in the competitive condition performed better in easy tasks than their counterparts in the non-competitive condition. However, they were more performance-oriented and more likely to sacrifice learning opportunities for better performance. They were also prone to have worse self-evaluation after failure. Although there were no statistically significant differences between the two conditions in task enjoyment and achievement attribution, the direction of the differences was consistently unfavourable to students in the competitive condition. The findings were consistent with the predictions of goal theory. Competitiveness induces performance goals and worse self-evaluation after failure among Chinese students in a classroom setting, as was found with Western students in a laboratory setting.
Atmospheric cloud physics thermal systems analysis
NASA Technical Reports Server (NTRS)
1977-01-01
Engineering analyses performed on the Atmospheric Cloud Physics (ACPL) Science Simulator expansion chamber and associated thermal control/conditioning system are reported. Analyses were made to develop a verified thermal model and to perform parametric thermal investigations to evaluate systems performance characteristics. Thermal network representations of solid components and the complete fluid conditioning system were solved simultaneously using the Systems Improved Numerical Differencing Analyzer (SINDA) computer program.
Lithium-Ion Batteries Being Evaluated for Low-Earth-Orbit Applications
NASA Technical Reports Server (NTRS)
McKissock, Barbara I.
2005-01-01
The performance characteristics and long-term cycle life of aerospace lithium-ion (Li-ion) batteries in low-Earth-orbit applications are being investigated. A statistically designed test using Li-ion cells from various manufacturers began in September 2004 to study the effects of temperature, end-of-charge voltage, and depth-of-discharge operating conditions on the cycle life and performance of these cells. Performance degradation with cycling is being evaluated, and performance characteristics and failure modes are being modeled statistically. As technology improvements are incorporated into aerospace Li-ion cells, these new designs can be added to the test to evaluate the effect of the design changes on performance and life. Cells from Lithion and Saft have achieved over 2000 cycles under 10 different test condition combinations and are being evaluated. Cells from Mine Safety Appliances (MSA) and modules made up of commercial-off-the-shelf 18650 Li-ion cells connected in series/parallel combinations are scheduled to be added in the summer of 2005. The test conditions include temperatures of 10, 20, and 30 C, end-of-charge voltages of 3.85, 3.95, and 4.05 V, and depth-of-discharges from 20 to 40 percent. The low-Earth-orbit regime consists of a 55 min charge, at a constant-current rate that is 110 percent of the current required to fully recharge the cells in 55 min until the charge voltage limit is reached, and then at a constant voltage for the remaining charge time. Cells are discharged for 35 min at the current required for their particular depth-of-discharge condition. Cells are being evaluated in four-cell series strings with charge voltage limits being applied to individual cells by the use of charge-control units designed and produced at the NASA Glenn Research Center. These charge-control units clamp the individual cell voltages as each cell reaches its end-of-charge voltage limit, and they bypass the excess current from that cell, while allowing the full current flow to the remaining cells in the pack. The goal of this evaluation is to identify conditions and cell designs for Li-ion technology that can achieve more than 30,000 low-Earth-orbit cycles. Testing is being performed at the Naval Surface Warfare Center, Crane Division, in Crane, Indiana.
Space shuttle orbital maneuvering engine platelet injector program
NASA Technical Reports Server (NTRS)
1975-01-01
A platelet-face injector for the fully reusable orbit maneuvering system OMS on the space shuttle was evaluated as a means of obtaining additional design margin and low cost. Performance, heat transfer, and combustion stability were evaluated over the anticipated range of OMS operating conditions. The effects of acoustic cavity configuration on combustion stability, including cavity depth, open area, inlet contour, and other parameters, were investigated using sea level bomb tests. Prototype injector and chamber behavior was evaluated for a variety of conditions; these tests examined the effects of film cooling, helium saturated propellants, chamber length, inlet conditions, and operating point, on performance, heat transfer and engine transient behavior. Helium bubble ingestion into both propellant circuits was investigated, as was chugging at low pressure operation, and hot and cold engine restart with and without a purge.
GICHD Mine Dog Testing Project - Soil Sample Results No.3
DOE Office of Scientific and Technical Information (OSTI.GOV)
PHELAN, JAMES M.; BARNETT, JAMES L.; BENDER, SUSAN FAE ANN
2003-03-01
A mine dog evaluation project initiated by the Geneva International Center for Humanitarian Demining is evaluating the capability and reliability of mine detection dogs. The performance of field-operational mine detection dogs will be measured in test minefields in Afghanistan and Bosnia containing actual, but unfused landmines. Repeated performance testing over two years through various seasonal weather conditions will provide data simulating near real world conditions. Soil samples will be obtained adjacent to the buried targets repeatedly over the course of the test. Chemical analysis results from these soil samples will be used to evaluate correlations between mine dog detection performancemore » and seasonal weather conditions. This report documents the analytical chemical methods and results from the third batch of soils received. This batch contained samples from Kharga, Afghanistan collected in October 2002.« less
USDA-ARS?s Scientific Manuscript database
Passive capillary samplers (PCAPs) are widely used to monitor, measure and sample drainage water under saturated and unsaturated soil conditions in the vadose zone. The objective of this study was to evaluate the performance and accuracy of automated passive capillary sampler for estimating drainage...
DOT National Transportation Integrated Search
2012-04-01
The goal of this study was to evaluate the performance of Fiber Bragg Grating (FBG) sensors able to detect impacts with : different frequencies on a bridge pier. The FBG technology was evaluated under controlled conditions in a laboratory : flume set...
USDA-ARS?s Scientific Manuscript database
Body condition score is used as a management tool to predict competency of reproduction in beef cows. Therefore, a retrospective study was performed to evaluate association of BCS at calving with subsequent pregnancy rate, days to first estrus, nutrient status (assessed by blood metabolites), and c...
Diffusion of 99-technetium in compacted bentonite under aerobic and anaerobic conditions
NASA Astrophysics Data System (ADS)
Večerník, P.; Jedináková-Křížová, V.
2006-01-01
The main aim of this study was to investigate diffusion of technetium 99Tc under different conditions. Because technetium represents one of the most dangerous fission products due to its very long halftime and high mobility in aerobic conditions diffusion experiments of technetium (as 99TcO
Performance of alkaline battery cells used in emergency locator transmitters
NASA Technical Reports Server (NTRS)
Haynes, G. A.; Sokol, S.; Motley, W. R., III; Mcclelland, E. L.
1984-01-01
The characteristics of battery power supplies for emergency locator transmitters (ELT's) were investigated by testing alkaline zinc/manganese dioxide cells of the type typically used in ELT's. Cells from four manufacturers were tested. The cells were subjected to simulated environmental and load conditions representative of those required for survival and operation. Battery cell characteristics that may contribute to ELT malfunctions and limitations were evaluated. Experimental results from the battery cell study are discussed, and an evaluation of ELT performance while operating under a representative worst-case environmental condition is presented.
Experimental Evaluation of Grid Support Enabled PV Inverter Response to Abnormal Grid Conditions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nelson, Austin A; Martin, Gregory D; Hurtt, James
As revised interconnection standards for grid-tied photovoltaic (PV) inverters address new advanced grid support functions (GSFs), there is increasing interest in inverter performance in the case of abnormal grid conditions. The growth of GSF-enabled inverters has outpaced the industry standards that define their operation, although recently published updates to UL1741 Supplement SA define test conditions for GSFs such as volt-var control, frequency-watt control, and voltage/frequency ride-through, among others. This paper describes the results of a comparative experimental evaluation on four commercially available, three-phase PV inverters in the 24.0-39.8 kVA power range on their GSF capability and its effect on abnormalmore » grid condition response. The evaluation examined the impact particular GSF implementations have on run-on times during islanding conditions, peak voltages in load rejection overvoltage scenarios, and peak currents during single-phase and three-phase fault events for individual inverters. Testing results indicated a wide variance in the performance of GSF enabled inverters to various test cases.« less
A protocol for evaluating video trackers under real-world conditions.
Nawaz, Tahir; Cavallaro, Andrea
2013-04-01
The absence of a commonly adopted performance evaluation framework is hampering advances in the design of effective video trackers. In this paper, we present a single-score evaluation measure and a protocol to objectively compare trackers. The proposed measure evaluates tracking accuracy and failure, and combines them for both summative and formative performance assessment. The proposed protocol is composed of a set of trials that evaluate the robustness of trackers on a range of test scenarios representing several real-world conditions. The protocol is validated on a set of sequences with a diversity of targets (head, vehicle and person) and challenges (occlusions, background clutter, pose changes and scale changes) using six state-of-the-art trackers, highlighting their strengths and weaknesses on more than 187000 frames. The software implementing the protocol and the evaluation results are made available online and new results can be included, thus facilitating the comparison of trackers.
Evaluation of Rankine cycle air conditioning system hardware by computer simulation
NASA Technical Reports Server (NTRS)
Healey, H. M.; Clark, D.
1978-01-01
A computer program for simulating the performance of a variety of solar powered Rankine cycle air conditioning system components (RCACS) has been developed. The computer program models actual equipment by developing performance maps from manufacturers data and is capable of simulating off-design operation of the RCACS components. The program designed to be a subroutine of the Marshall Space Flight Center (MSFC) Solar Energy System Analysis Computer Program 'SOLRAD', is a complete package suitable for use by an occasional computer user in developing performance maps of heating, ventilation and air conditioning components.
Pediatric Eye Screening Instrumentation
NASA Astrophysics Data System (ADS)
Chen, Ying-Ling; Lewis, J. W. L.
2001-11-01
Computational evaluations are presented for binocular eye screening using the off-axis digital retinascope. The retinascope, such as the iScreen digital screening system, has been employed to perform pediatric binocular screening using a flash lamp and single-shot camera recording. The digital images are transferred electronically to a reading center for analysis. The method has been shown to detect refractive error, amblyopia, anisocoria, and ptosis. This computational work improves the performance of the system and forms the basis for automated data analysis. For this purpose, variouis published eye models are evaluated with simulated retinascope images. Two to ten million rays are traced in each image calculation. The poster will present the simulation results for a range of eye conditions of refractive error of -20 to +20 diopters with 0.5- to-1 diopter resolution, pupil size of 3 to 8 mm diameter (1-mm increment), and staring angle of 2 to 12 degree (2-degree increment). The variation of the results with the system conditions such as the off-axis distance of light source and the shutter size of camera are also evaluated. The quantitative analysis for each eye’s and system’s condition is then performed to obtain parameters for automatic reading. The summary of the system performance is given and performance-enhancement design modifications are presented.
Ames Research Center Shear Tests of SLA-561V Heat Shield Material for Mars-Pathfinder
NASA Technical Reports Server (NTRS)
Tauber, Michael; Tran, Huy; Henline, William; Cartledge, Alan; Hui, Frank; Tran, Duoc; Zimmerman, Norm
1996-01-01
This report describes the results of arc-jet testing at Ames Research Center on behalf of Jet Propulsion Laboratory (JPL) for the development of the Mars-Pathfinder heat shield. The current test series evaluated the performance of the ablating SLA-561V heat shield material under shear conditions. In addition, the effectiveness of several methods of repairing damage to the heat shield were evaluated. A total of 26 tests were performed in March 1994 in the 2 in. X 9 in. arc-heated turbulent Duct Facility, including runs to calibrate the facility to obtain the desired shear stress conditions. A total of eleven models were tested. Three different conditions of shear and heating were used. The non-ablating surface shear stresses and the corresponding, approximate, non-ablating surface heating rates were as follows: Condition 1, 170 N/m(exp 2) and 22 W/cm(exp 2); Condition 2, 240 N/m(exp 2) and 40 W/cm(exp 2); Condition 3, 390 N/m(exp 2) and 51 W/cm(exp 2). The peak shear stress encountered in flight is represented approximately by Condition 1; however, the heating rate was much less than the peak flight value. The peak heating rate that was available in the facility (at Condition 3) was about 30 percent less than the maximum value encountered during flight. Seven standard ablation models were tested, of which three models were instrumented with thermocouples to obtain in-depth temperature profiles and temperature contours. An additional four models contained a variety of repair plugs, gaps, and seams. These models were used to evaluated different repair materials and techniques, and the effect of gaps and construction seams. Mass loss and surface recession measurements were made on all models. The models were visually inspected and photographed before and after each test. The SLA-561 V performed well; even at test Condition 3, the char remained intact. Most of the resins used for repairs and gap fillers performed poorly. However, repair plugs made of SLA-561V performed well. Approximately 70 percent of the thermocouples yielded good data.
Manufacture and evaluation of Li/BCX DD cells
NASA Technical Reports Server (NTRS)
Meyer, S.; Takeuchi, E.
1990-01-01
This project is divided into four main tasks: cell manufacture, acceptance, and lot certification of cells, performance testing of cells, and abuse testing of cells. Lithium/bromine chloride in thionyl chloride (Li/BCX) 149 DD cells (PN 3B2085-XA) were built according to the provisions of Electrochem Industries Quality Plan 17096. Acceptance and lot certification testing was performed according to NASA JSC Document EP5-83-025, Revision B. Acceptance testing included open circuit and load voltage check, visual examination, size and weight measurements, and high temperature exposure. Lot certification tests were performed for capacity performance and for performance under conditions of thermal and electrical abuse. These tests included 149 C exposure, capacity discharge, fuse check, high temperature exposure, high rate discharge, short circuit, vibration, and overdischarge testing. A quantity of 200 cells was delivered to Johnson Space Center for life test evaluation. A parametric evaluation of the capacity discharge of Li/BCX DD cells was performed over a variety of temperatures and discharge rates. This testing served to map the performance capability of the cell. Tests were also performed over a variety of electrical and thermal abuse conditions. Abuse tests included short circuit, charging, overdischarge, high temperature exposure, shock, and vibration.
Klingner, Thomas D; Boeniger, Mark F
2002-05-01
Wearing chemical-resistant gloves and clothing is the primary method used to prevent skin exposure to toxic chemicals in the workplace. The process for selecting gloves is usually based on manufacturers' laboratory-generated chemical permeation data. However, such data may not reflect conditions in the workplace where many variables are encountered (e.g., elevated temperature, flexing, pressure, and product variation between suppliers). Thus, the reliance on this selection process is questionable. Variables that may influence the performance of chemical-resistant gloves are identified and discussed. Passive dermal monitoring is recommended to evaluate glove performance under actual-use conditions and can bridge the gap between laboratory data and real-world performance.
Age, altitude, and workload effects on complex performance.
DOT National Transportation Integrated Search
1983-09-01
Fifteen healthy men in each of three age groups, 20-29 yrs, 40-49 yrs, and 60-69 yrs, were evaluated regarding complex performance in two altitude conditions (ground level vs. 3,810 m) which were administered during performance testing. Performance w...
Skylab experiment performance evaluation manual. Appendix F: Experiment M551 Metals melting (MSFC)
NASA Technical Reports Server (NTRS)
Byers, M. S.
1973-01-01
Analyses for Experiment M551 Metals Melting (MSFC), to be used for evaluating the performance of the Skylab corollary experiments under preflight, inflight, and post-flight conditions are presented. Experiment contingency plan workaround procedure and malfunction analyses are presented in order to assist in making the experiment operationally successful.
Skylab experiment performance evaluation manual. Appendix H: Experiment M553 sphere forming (MSFC)
NASA Technical Reports Server (NTRS)
Thomas, O. H., Jr.
1973-01-01
Analyses for Experiment M553 Sphere Forming (MSFC), to be used for evaluating the performance of the Skylab corollary experiments under preflight, inflight, and post-flight conditions are presented. Experiment contingency plan workaround procedure and malfunction analyses are presented in order to assist in making the experiment operationally successful.
The main objective of this study is to evaluate the performance of sampling methods for potential use as a Federal Reference Method (FRM) capable of providing an estimate of coarse particle (PMc: particulate matter with an aerodynamic diameter between 2.5 um and 10 um) mass con...
Remote control circuit breaker evaluation testing. [for space shuttles
NASA Technical Reports Server (NTRS)
Bemko, L. M.
1974-01-01
Engineering evaluation tests were performed on several models/types of remote control circuit breakers marketed in an attempt to gain some insight into their potential suitability for use on the space shuttle vehicle. Tests included the measurement of several electrical and operational performance parameters under laboratory ambient, space simulation, acceleration and vibration environmental conditions.
Evaluation of the PV energy production after 12-years of operating
NASA Astrophysics Data System (ADS)
Bouchakour, Salim; Arab, Amar Hadj; Abdeladim, Kamel; Boulahchiche, Saliha; Amrouche, Said Ould; Razagui, Abdelhak
2018-05-01
This paper presents a simple way to approximately evaluate the photovoltaic (PV) array performance degradation, the studied PV arrays are connected to the local electric grid at the Centre de Developpement des Energies Renouvelables (CDER) in Algiers, Algeria, since June 2004. The used PV module model takes in consideration the module temperature and the effective solar radiance, the electrical characteristics provided by the manufacturer data sheet and the evaluation of the performance coefficient. For the dynamic behavior we use the Linear Reoriented Coordinates Method (LRCM) to estimate the maximum power point (MPP). The performance coefficient is evaluated on the one hand under STC conditions to estimate the dc energy according to the manufacturer data. On the other hand, under real conditions using both the monitored data and the LM optimization algorithm, allowing a good degree of accuracy of estimated dc energy. The application of the developed modeling procedure to the analysis of the monitored data is expected to improve understanding and assessment of the PV performance degradation of the PV arrays after 12 years of operation.
NASA Technical Reports Server (NTRS)
Parrish, R. V.; Steinmetz, G. G.
1983-01-01
Vertical-motion cues supplied by a g-seat to augment platform motion cues in the other five degrees of freedom were evaluated in terms of their effect on objective performance measures obtained during simulated transport landings under visual conditions. In addition to evaluating the effects of the vertical cueing, runway width and magnification effects were investigated. The g-seat was evaluated during fixed base and moving-base operations. Although performance with the g-seat only improved slightly over that with fixed-base operation, combined g-seat platform operation showed no improvement over improvement over platform-only operation. When one runway width at one magnification factor was compared with another width at a different factor, the visual results indicated that the runway width probably had no effect on pilot-vehicle performance. The new performance differences that were detected may be more readily attributed to the extant (existing throughout) increase in vertical velocity induced by the magnification factor used to change the runway width, rather than to the width itself.
Turboprop aircraft performance response to various environmental conditions
NASA Astrophysics Data System (ADS)
Ashenden, Russell Allen
1997-10-01
This study evaluated aircraft and airfoil performance response to various environmental conditions. These conditions included clear air, warm rain, ice only, mixed phase and supercooled drops encountered during 19 separate flights. Supercooled droplets consisting of cloud, drizzle and rain sizes were the main focus of this study. Aircraft response was quantified by rates of change in aircraft rate-of-climb capability, lift and drag coefficients and lift over drag ratio. Airfoil degradation due to simulated ice shapes and drizzle ice roughness was measured in a wind tunnel for comparison. The aircraft performance parameters were compared to environmental hydrometeor parameters quantifying the environmental conditions. Results show that encounters with supercooled drizzle drops, or SCDD, resulted in maximum rates of performance degradation. These high rates of degradation forced the pilot to take evasive action within 5 minutes of entering these hazardous conditions. Encounters with supercooled cloud and rain sized drops resulted in minor to low rates of performance degradation whereas encounters with supercooled drops in low ice particle concentrations resulted in only minor rates of degradation. In addition, aircraft response to high ice particle concentrations and low liquid water, following an SCDD encounter, resulted in rapid performance recovery. The airfoil evaluations show similar results where the drizzle drop ice shape and simulated drizzle ice roughness resulted in the highest performance degradation. These evaluations also show that the most sensitive surface location is on the suction side between 6 and at least 11% of airfoil chord. Ice contaminations in this area are beyond the protective de-icing boots of most aircraft and lead to severe degradations in lift and drag characteristics. The results presented herein show a strong relationship between aircraft response and environmental parameters utilizing the larger drops in the hydrometeor distribution. The results suggest that the most severe icing is actually caused by drizzle sized drops as opposed to freezing rain. Furthermore, these results are similar to many twin-turboprop aircraft typically utilized by the commuter fleet.
GICHD mine dog testing project - soil sample results #4.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnett, James L.; Phelan, James M.; Archuleta, Luisa M.
2003-08-01
A mine dog evaluation project initiated by the Geneva International Center for Humanitarian Demining is evaluating the capability and reliability of mine detection dogs. The performance of field-operational mine detection dogs will be measured in test minefields in Afghanistan and Bosnia containing actual, but unfused landmines. Repeated performance testing over two years through various seasonal weather conditions will provide data simulating near real world conditions. Soil samples will be obtained adjacent to the buried targets repeatedly over the course of the test. Chemical analysis results from these soil samples will be used to evaluate correlations between mine dog detection performancemore » and seasonal weather conditions. This report documents the analytical chemical methods and results from the fourth batch of soils received. This batch contained samples from Kharga, Afghanistan collected in April 2003 and Sarajevo, Bosnia collected in May 2003.« less
WRF/CMAQ AQMEII3 Simulations of US Regional-Scale ...
Chemical boundary conditions are a key input to regional-scale photochemical models. In this study, performed during the third phase of the Air Quality Model Evaluation International Initiative (AQMEII3), we perform annual simulations over North America with chemical boundary conditions prepared from four different global models. Results indicate that the impacts of different boundary conditions are significant for ozone throughout the year and most pronounced outside the summer season. The National Exposure Research Laboratory (NERL) Computational Exposure Division (CED) develops and evaluates data, decision-support tools, and models to be applied to media-specific or receptor-specific problem areas. CED uses modeling-based approaches to characterize exposures, evaluate fate and transport, and support environmental diagnostics/forensics with input from multiple data sources. It also develops media- and receptor-specific models, process models, and decision support tools for use both within and outside of EPA.
Evaluation of UV-C mutagenized Scheffersomyces stipitis strains for ethanol production.
Geiger, Melanie; Gibbons, Jaimie; West, Thomas; Hughes, Stephen R; Gibbons, William
2012-12-01
We evaluated fermentation capabilities of five strains of Scheffersomyces stipitis (WT-2-1, WT-1-11, 14-2-6, 22-1-1, and 22-1-12) that had been produced by UV-C mutagenesis and selection for improved xylose fermentation to ethanol using an integrated automated robotic work cell. They were incubated under both facultative and anaerobic conditions to evaluate ethanol production on glucose, xylose, cellobiose, and a combination of all three sugars. The medium contained 50 g/L total sugar and 5 g/L yeast extract. The strains performed significantly better under facultative compared with anaerobic conditions. As expected, glucose was the most readily fermented sugar with ~100% fermentation efficiency (FE) under facultative conditions but only 5% to 16% FE anaerobically. Xylose utilization was 20% to 40% FE under facultative conditions but 9% to 25% FE anaerobically. Cellobiose was the least fermented sugar, at 18% to 27% FE facultatively and 8% to 11% anaerobically. Similar trends occurred in the sugar mixture. Under facultative conditions, strain 22-1-12 produced 19.6 g/L ethanol on glucose, but strain 14-2-6 performed best on xylose (4.5 g/L ethanol) and the sugar combination (8.0 g/L ethanol). Ethanol titers from glucose under anaerobic conditions were again highest with strain 22-1-12, but none of the strains produced ethanol from xylose. Future trials will evaluate nutrient addition to boost microaerophilic xylose fermentation.
Yoshie, Michiko; Kudo, Kazutoshi; Murakoshi, Takayuki; Ohtsuki, Tatsuyuki
2009-11-01
Music performance anxiety (MPA), or stage fright in music performance, is a serious problem for many musicians, because performance impairment accompanied by MPA can threaten their career. The present study sought to clarify on how a social-evaluative performance situation affects subjective, autonomic, and motor stress responses in pianists. Measurements of subjective state anxiety, heart rate (HR), sweat rate (SR), and electromyographic (EMG) activity of upper extremity muscles were obtained while 18 skilled pianists performed a solo piano piece(s) of their choice under stressful (competition) and non-stressful (rehearsal) conditions. Participants reported greater anxiety in the competition condition, which confirmed the effectiveness of stress manipulation. The HR and SR considerably increased from the rehearsal to competition condition reflecting the activation of sympathetic division of the autonomic nervous system. Furthermore, participants showed higher levels of the EMG magnitude of proximal muscles (biceps brachii and upper trapezius) and the co-contraction of antagonistic muscles in the forearm (extensor digitorum communis and flexor digitorum superficialis) in the competition condition. Although these responses can be interpreted as integral components of an adaptive biological system that creates a state of motor readiness in an unstable or unpredictable environment, they can adversely influence pianists by disrupting their fine motor control on stage and by increasing the risk of playing-related musculoskeletal disorders.
Evaluation of Alternative Refrigerants for Mini-Split Air Conditioners
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abdelaziz, Omar; Shrestha, Som S
The phase-out of hydrochlorofluorocarbons (HCFC) refrigerants in developing countries is currently underway according to the Montreal Protocol. R-22 is one of the most commonly used HCFCs in the developing nations. It is extremely well suited for air conditioning and refrigeration (AC&R) in high ambient temperature environments. Non-Article 5 countries have already gone through the phase-out of HCFCs and settled on using R-410A as the refrigerant of choice for AC applications. Previous studies have shown that R-410A results in significant capacity and performance degradation at higher ambient temperature conditions. As such, there is a growing concern on finding alternative refrigerants tomore » R-22 that would have zero ODP, lower GWP, and at the same time maintain acceptable performance at higher ambient temperatures. Furthermore, the developed world s transition through higher global warming potential (GWP) refrigerants like HFC and HFC blends resulted in significant direct CO2 equivalent emissions. It is imperative to develop a bridge for developing nations to avoid the transition from HCFC to HFC and then from HFC to alternative lower GWP refrigerants. This paper summarizes data from an experimental campaign on alternative refrigerant evaluation for R-22 and R-410A substitutes for mini-split air conditioners designed for high ambient environments. The experimental evaluation was performed according to ANSI/ASHRAE Standard 37 and the performance was rated at test conditions specified by ANSI/AHRI 210-240 and ISO 5151. Additional tests were conducted at outdoor ambient temperatures of 52 C (125.6 F) and 55 C (131 F) to evaluate their performance at high ambient conditions. Alternative refrigerants, some of which are proprietary, included R-444B, DR-3, N-20b, ARM-20b, R-290, and DR-93 as alternatives to R-22 and R-32, DR-55, L41-2, ARM-71A, and HPR-2A as alternatives to R-410A. The units performances were first verified using the baseline refrigerant and then drop-in refrigerant evaluation followed including soft optimization to ensure refrigerant performance is adequately represented. The soft optimization included: 1) charge optimization, 2) lubricant change, and 3) flow control. The paper presents the relative performances (efficiency and capacity) of the alternative refrigerants compared to the baseline refrigerants at the different operating conditions. Paper concludes with remarks about the suitability of alternative refrigerants for R-22 and R-410A applications in high ambient temperature regions.« less
Optimizing the Combination of Acoustic and Electric Hearing in the Implanted Ear
Karsten, Sue A.; Turner, Christopher W.; Brown, Carolyn J.; Jeon, Eun Kyung; Abbas, Paul J.; Gantz, Bruce J.
2016-01-01
Objectives The aim of this study was to determine an optimal approach to program combined acoustic plus electric (A+E) hearing devices in the same ear to maximize speech-recognition performance. Design Ten participants with at least 1 year of experience using Nucleus Hybrid (short electrode) A+E devices were evaluated across three different fitting conditions that varied in the frequency ranges assigned to the acoustically and electrically presented portions of the spectrum. Real-ear measurements were used to optimize the acoustic component for each participant, and the acoustic stimulation was then held constant across conditions. The lower boundary of the electric frequency range was systematically varied to create three conditions with respect to the upper boundary of the acoustic spectrum: Meet, Overlap, and Gap programming. Consonant recognition in quiet and speech recognition in competing-talker babble were evaluated after participants were given the opportunity to adapt by using the experimental programs in their typical everyday listening situations. Participants provided subjective ratings and evaluations for each fitting condition. Results There were no significant differences in performance between conditions (Meet, Overlap, Gap) for consonant recognition in quiet. A significant decrement in performance was measured for the Overlap fitting condition for speech recognition in babble. Subjective ratings indicated a significant preference for the Meet fitting regimen. Conclusions Participants using the Hybrid ipsilateral A+E device generally performed better when the acoustic and electric spectra were programmed to meet at a single frequency region, as opposed to a gap or overlap. Although there is no particular advantage for the Meet fitting strategy for recognition of consonants in quiet, the advantage becomes evident for speech recognition in competing-talker babble and in patient preferences. PMID:23059851
Advanced Pathway Guidance Evaluations on a Synthetic Vision Head-Up Display
NASA Technical Reports Server (NTRS)
Kramer, Lynda J.; Prinzel, Lawrence J., III; Arthur, Jarvis J., III; Bailey, Randall E.
2005-01-01
NASA's Synthetic Vision Systems (SVS) project is developing technologies with practical applications to potentially eliminate low visibility conditions as a causal factor to civil aircraft accidents while replicating the operational benefits of clear day flight operations, regardless of the actual outside visibility condition. A major thrust of the SVS project involves the development/demonstration of affordable, certifiable display configurations that provide intuitive out-the-window terrain and obstacle information with advanced guidance for commercial and business aircraft. This experiment evaluated the influence of different pathway and guidance display concepts upon pilot situation awareness (SA), mental workload, and flight path tracking performance for Synthetic Vision display concepts using a Head-Up Display (HUD). Two pathway formats (dynamic and minimal tunnel presentations) were evaluated against a baseline condition (no tunnel) during simulated instrument meteorological conditions approaches to Reno-Tahoe International airport. Two guidance cues (tadpole, follow-me aircraft) were also evaluated to assess their influence. Results indicated that the presence of a tunnel on an SVS HUD had no effect on flight path performance but that it did have significant effects on pilot SA and mental workload. The dynamic tunnel concept with the follow-me aircraft guidance symbol produced the lowest workload and provided the highest SA among the tunnel concepts evaluated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ascough, II, James Clifford
1992-05-01
The capability to objectively evaluate design performance of shallow landfill burial (SLB) systems is of great interest to diverse scientific disciplines, including hydrologists, engineers, environmental scientists, and SLB regulators. The goal of this work was to develop and validate a procedure for the nonsubjective evaluation of SLB designs under actual or simulated environmental conditions. A multiobjective decision module (MDM) based on scoring functions (Wymore, 1988) was implemented to evaluate SLB design performance. Input values to the MDM are provided by hydrologic models. The MDM assigns a total score to each SLB design alternative, thereby allowing for rapid and repeatable designmore » performance evaluation. The MDM was validated for a wide range of SLB designs under different climatic conditions. Rigorous assessment of SLB performance also requires incorporation of hydrologic probabilistic analysis and hydrologic risk into the overall design. This was accomplished through the development of a frequency analysis module. The frequency analysis module allows SLB design event magnitudes to be calculated based on the hydrologic return period. The multiobjective decision and freqeuncy anslysis modules were integrated in a decision support system (DSS) framework, SLEUTH (Shallow Landfill Evaluation Using Transport and Hydrology). SLEUTH is a Microsoft Windows {trademark} application, and is written in the Knowledge Pro Windows (Knowledge Garden, Inc., 1991) development language.« less
Influence of 2D and 3D view on performance and time estimation in minimal invasive surgery.
Blavier, A; Nyssen, A S
2009-11-01
This study aimed to evaluate the impact of two-dimensional (2D) and three-dimensional (3D) images on time performance and time estimation during a surgical motor task. A total of 60 subjects without any surgical experience (nurses) and 20 expert surgeons performed a fine surgical task with a new laparoscopic technology (da Vinci robotic system). The 80 subjects were divided into two groups, one using 3D view option and the other using 2D view option. We measured time performance and asked subjects to verbally estimate their time performance. Our results showed faster performance in 3D than in 2D view for novice subjects while the performance in 2D and 3D was similar in the expert group. We obtained a significant interaction between time performance and time evaluation: in 2D condition, all subjects accurately estimated their time performance while they overestimated it in the 3D condition. Our results emphasise the role of 3D in improving performance and the contradictory feeling about time evaluation in 2D and 3D. This finding is discussed in regard with the retrospective paradigm and suggests that 2D and 3D images are differently processed and memorised.
Evaluation of a pilot workload metric for simulated VTOL landing tasks
NASA Technical Reports Server (NTRS)
North, R. A.; Graffunder, K.
1979-01-01
A methodological approach to measuring workload was investigated for evaluation of new concepts in VTOL aircraft displays. Multivariate discriminant functions were formed from conventional flight performance and/or visual response variables to maximize detection of experimental differences. The flight performance variable discriminant showed maximum differentiation between crosswind conditions. The visual response measure discriminant maximized differences between fixed vs. motion base conditions and experimental displays. Physiological variables were used to attempt to predict the discriminant function values for each subject/condition/trial. The weights of the physiological variables in these equations showed agreement with previous studies. High muscle tension, light but irregular breathing patterns, and higher heart rate with low amplitude all produced higher scores on this scale and thus, represented higher workload levels.
The report discusses and gives results of a pilot field study to evaluate the effectiveness of air duct cleaning (ADC) as a source removal technique in residential heating and air-conditioning (HAC) systems and its impact on airborne particle, fiber, and bioaerosol concentrations...
NASA Technical Reports Server (NTRS)
1979-01-01
The test procedures and the results obtained during the evaluation of a single-covered liquid solar collector are presented. The tests were performed under outdoor natural conditions. The collector was under stagnation conditions for a total of approximately ten months. The solar collector is a liquid, single-glazed, flat plate collector, and is about 240 inches long, and 3.8 inches in depth.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kung, F.; Deru, M.; Bonnema, E.
2013-10-01
Few third-party guidance documents or tools are available for evaluating thermal energy storage (TES) integrated with packaged air conditioning (AC), as this type of TES is relatively new compared to TES integrated with chillers or hot water systems. To address this gap, researchers at the National Renewable Energy Laboratory conducted a project to improve the ability of potential technology adopters to evaluate TES technologies. Major project outcomes included: development of an evaluation framework to describe key metrics, methodologies, and issues to consider when assessing the performance of TES systems integrated with packaged AC; application of multiple concepts from the evaluationmore » framework to analyze performance data from four demonstration sites; and production of a new simulation capability that enables modeling of TES integrated with packaged AC in EnergyPlus. This report includes the evaluation framework and analysis results from the project.« less
Evaluation of warm mix asphalt for Alaska conditions : [summary].
DOT National Transportation Integrated Search
2010-09-01
This project developed and tested protocols to determine concrete curing strength during the construction process, so that : building under very cold conditions can be performed safely and quickly. Researchers determined the laboratory strengthmaturi...
Gear Fault Detection Effectiveness as Applied to Tooth Surface Pitting Fatigue Damage
NASA Technical Reports Server (NTRS)
Lewicki, David G.; Dempsey, Paula J.; Heath, Gregory F.; Shanthakumaran, Perumal
2009-01-01
A study was performed to evaluate fault detection effectiveness as applied to gear tooth pitting fatigue damage. Vibration and oil-debris monitoring (ODM) data were gathered from 24 sets of spur pinion and face gears run during a previous endurance evaluation study. Three common condition indicators (RMS, FM4, and NA4) were deduced from the time-averaged vibration data and used with the ODM to evaluate their performance for gear fault detection. The NA4 parameter showed to be a very good condition indicator for the detection of gear tooth surface pitting failures. The FM4 and RMS parameters performed average to below average in detection of gear tooth surface pitting failures. The ODM sensor was successful in detecting a significant amount of debris from all the gear tooth pitting fatigue failures. Excluding outliers, the average cumulative mass at the end of a test was 40 mg.
Evaluation of Containment Boxes as a Fire Mitigation Method in Elevated Oxygen Conditions
NASA Technical Reports Server (NTRS)
Juarez, Alfredo; Harper, Susana; Perez, Horacio
2016-01-01
NASA performed testing to evaluate the efficacy of fire containment boxes without forced ventilation. Configurational flammability testing was performed on a simulation avionics box replicating critical design features and filled with materials possessing representative flammability characteristics. This paper discusses the box's ability, under simulated end-use conditions, to inhibit the propagation of combustion to surrounding materials. Analysis was also performed to evaluate the potential for the fire containment box to serve as an overheat/ignition source to temperature sensitive equipment (such as items with lithium-ion batteries). Unrealistically severe combustion scenarios were used as a means to better understand the fire containment mechanism. These scenarios were achieved by utilizing materials/fuels not typically used in space vehicles due to flammability concerns. Oxygen depletion, during combustion within the fire containment boxes, drove self-extinguishment and proved an effective method of fire containment
Performance Evaluation and Analysis for Gravity Matching Aided Navigation.
Wu, Lin; Wang, Hubiao; Chai, Hua; Zhang, Lu; Hsu, Houtse; Wang, Yong
2017-04-05
Simulation tests were accomplished in this paper to evaluate the performance of gravity matching aided navigation (GMAN). Four essential factors were focused in this study to quantitatively evaluate the performance: gravity database (DB) resolution, fitting degree of gravity measurements, number of samples in matching, and gravity changes in the matching area. Marine gravity anomaly DB derived from satellite altimetry was employed. Actual dynamic gravimetry accuracy and operating conditions were referenced to design the simulation parameters. The results verified that the improvement of DB resolution, gravimetry accuracy, number of measurement samples, or gravity changes in the matching area generally led to higher positioning accuracies, while the effects of them were different and interrelated. Moreover, three typical positioning accuracy targets of GMAN were proposed, and the conditions to achieve these targets were concluded based on the analysis of several different system requirements. Finally, various approaches were provided to improve the positioning accuracy of GMAN.
Performance Evaluation and Analysis for Gravity Matching Aided Navigation
Wu, Lin; Wang, Hubiao; Chai, Hua; Zhang, Lu; Hsu, Houtse; Wang, Yong
2017-01-01
Simulation tests were accomplished in this paper to evaluate the performance of gravity matching aided navigation (GMAN). Four essential factors were focused in this study to quantitatively evaluate the performance: gravity database (DB) resolution, fitting degree of gravity measurements, number of samples in matching, and gravity changes in the matching area. Marine gravity anomaly DB derived from satellite altimetry was employed. Actual dynamic gravimetry accuracy and operating conditions were referenced to design the simulation parameters. The results verified that the improvement of DB resolution, gravimetry accuracy, number of measurement samples, or gravity changes in the matching area generally led to higher positioning accuracies, while the effects of them were different and interrelated. Moreover, three typical positioning accuracy targets of GMAN were proposed, and the conditions to achieve these targets were concluded based on the analysis of several different system requirements. Finally, various approaches were provided to improve the positioning accuracy of GMAN. PMID:28379178
Schmidt, Jürgen; Laarousi, Rihab; Stolzmann, Wolfgang; Karrer-Gauß, Katja
2018-06-01
In this article, we examine the performance of different eye blink detection algorithms under various constraints. The goal of the present study was to evaluate the performance of an electrooculogram- and camera-based blink detection process in both manually and conditionally automated driving phases. A further comparison between alert and drowsy drivers was performed in order to evaluate the impact of drowsiness on the performance of blink detection algorithms in both driving modes. Data snippets from 14 monotonous manually driven sessions (mean 2 h 46 min) and 16 monotonous conditionally automated driven sessions (mean 2 h 45 min) were used. In addition to comparing two data-sampling frequencies for the electrooculogram measures (50 vs. 25 Hz) and four different signal-processing algorithms for the camera videos, we compared the blink detection performance of 24 reference groups. The analysis of the videos was based on very detailed definitions of eyelid closure events. The correct detection rates for the alert and manual driving phases (maximum 94%) decreased significantly in the drowsy (minus 2% or more) and conditionally automated (minus 9% or more) phases. Blinking behavior is therefore significantly impacted by drowsiness as well as by automated driving, resulting in less accurate blink detection.
ERIC Educational Resources Information Center
Liu, Boquan; Polce, Evan; Sprott, Julien C.; Jiang, Jack J.
2018-01-01
Purpose: The purpose of this study is to introduce a chaos level test to evaluate linear and nonlinear voice type classification method performances under varying signal chaos conditions without subjective impression. Study Design: Voice signals were constructed with differing degrees of noise to model signal chaos. Within each noise power, 100…
ERIC Educational Resources Information Center
Kodak, Tiffany; Clements, Andrea; Paden, Amber R.; LeBlanc, Brittany; Mintz, Joslyn; Toussaint, Karen A.
2015-01-01
The current investigation evaluated repertoires that may be related to performance on auditory-to-visual conditional discrimination training with 9 students who had been diagnosed with autism spectrum disorder. The skills included in the assessment were matching, imitation, scanning, an auditory discrimination, and a visual discrimination. The…
Skylab experiment performance evaluation manual. Appendix K: Experiment S009 nuclear emulsion (MSFC)
NASA Technical Reports Server (NTRS)
Meyers, J. E.
1972-01-01
A series of analyses are presented for Experiment S009, nuclear emulsion (MSFC), to be used for evaluating the performance of the Skylab corollary experiments under preflight, inflight, and postflight conditions. Experiment contingency plan workaround procedure and malfunction analyses are included in order to assist in making the experiment operationally successful.
40 CFR 63.8005 - What requirements apply to my process vessels?
Code of Federal Regulations, 2010 CFR
2010-07-01
... condensers, as defined in § 63.1251, are not considered to be control devices for process vessels. (d... 1 to this subpart, you must conduct the performance test or design evaluation under conditions as specified in § 63.7(e)(1), except that the performance test or design evaluation must be conducted under...
NASA Technical Reports Server (NTRS)
Purushotham, K. S.
1972-01-01
A series is presented of analyses for Experiment S183, Ultraviolet Panorama (MSFC), to be used for evaluating the performance of the Skylab corollary experiments under preflight, inflight, and post-flight conditions. Experiment contingency plan workaround procedure and malfunction analyses are presented in order to assist in making the experiment operationally successful.
Shiyuan Zhong; Xiuping Li; Xindi Bian; Warren E. Heilman; L. Ruby Leung; William I. Jr. Gustafson
2012-01-01
The performance of regional climate simulations is evaluated for the Great Lakes region. Three 10-year (1990-1999) current-climate simulations are performed using the MM5 regional climate model (RCM) with 36-km horizontal resolution. The simulations employed identical configuration and physical parameterizations, but different lateral boundary conditions and sea-...
NASA Technical Reports Server (NTRS)
Purushotham, K. S.
1972-01-01
A series of analyses is presented for experiment T003, inflight aerosol analysis, to be used for evaluating the performance of the Skylab corollary experiments under preflight, inflight, and post-flight conditions. Experiment contingency plan workaround procedure and malfunction analyses are presented in order to assist in making the experiment operationally successful.
NASA Technical Reports Server (NTRS)
Purushotham, K. S.
1972-01-01
A series of analyses for Experiment T002, Navigation Sightings (MSFC), to be used for evaluating the performance of the Skylab corollary experiments under preflight, inflight, and post-flight conditions are presented. Experiment contingency plan workaround procedure and malfunction analyses are presented in order to assist in making the experiment operationally successful.
NASA Technical Reports Server (NTRS)
Tonetti, B. B.
1973-01-01
Analyses for Experiment T027, Contamination Measurement Sample Array (MSFC), to be used for evaluating the performance of the Skylab corrollary experiments under preflight, inflight, and post-flight conditions are presented. Experiment contingency plan workaround procedure and malfunction analyses are presented in order to assist in making the experiment operationally successful.
Effects of incentives on psychosocial performances in simulated space-dwelling groups
NASA Astrophysics Data System (ADS)
Hienz, Robert D.; Brady, Joseph V.; Hursh, Steven R.; Gasior, Eric D.; Spence, Kevin R.; Emurian, Henry H.
Prior research with individually isolated 3-person crews in a distributed, interactive, planetary exploration simulation examined the effects of communication constraints and crew configuration changes on crew performance and psychosocial self-report measures. The present report extends these findings to a model of performance maintenance that operationalizes conditions under which disruptive affective responses by crew participants might be anticipated to emerge. Experiments evaluated the effects of changes in incentive conditions on crew performance and self-report measures in simulated space-dwelling groups. Crews participated in a simulated planetary exploration mission that required identification, collection, and analysis of geologic samples. Results showed that crew performance effectiveness was unaffected by either positive or negative incentive conditions, while self-report measures were differentially affected—negative incentive conditions produced pronounced increases in negative self-report ratings and decreases in positive self-report ratings, while positive incentive conditions produced increased positive self-report ratings only. Thus, incentive conditions associated with simulated spaceflight missions can significantly affect psychosocial adaptation without compromising task performance effectiveness in trained and experienced crews.
NASA Astrophysics Data System (ADS)
Du, Xiaorong
2017-04-01
Water is the basic condition for human survival and development. As China is the most populous country, rural drinking water safety problems are most conspicuous. Therefore, the Chinese government keeps increasing investment and has built a large number of rural drinking water safety projects. Scientific evaluation of project performance is of great significance to promote the sustainable operation of the project and the sustainable development of rural economy. Previous studies mainly focus on the economic benefits of the project, while ignoring the fact that the rural drinking water safety project is quasi-public goods, which has economic, social and ecological benefits. This paper establishes a comprehensive evaluation model for rural drinking water safety performance, which adapts the rules of "5E" (economy, efficiency, effectiveness, equity and environment) as the value orientation, and selects a rural drinking water safety project as object in case study at K District, which is in the north of Jiangsu Province, China. The results shows: 1) the comprehensive performance of K project is in good condition; 2) The performance of every part shows that the scores of criteria "efficiency", "environment" and "effect" are higher than the mean performance, while the "economy" is slightly lower than the mean and the "equity" is the lowest. 3) The performance of indicator layer shows that: the planned completion rate of project, the reduction rate of project cost and the penetration rate of water-use population are significantly lower than other indicators. Based on the achievements of previous studies and the characteristics of rural drinking water safety project, this study integrates the evaluation dimensions of equity and environment, which can contribute to a more comprehensive and systematic assessment of project performance and provide empirical data for performance evaluation and management of rural drinking water safety project. Key Words: Rural drinking water safety project; Performance evaluation; 5E rules; Comprehensive evaluation model
Performance and life evaluation of advanced battery technologies for electric vehicle applications
NASA Astrophysics Data System (ADS)
Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.
Advanced battery technology evaluations are performed under simulated electric vehicle (EV) operating conditions at the Argonne Analysis and Diagnostic Laboratory (ADL). The ADL provides a common basis for both performance characterization and life evaluation with unbiased application of tests and analyses. This paper summarizes the performance characterizations and life evaluations conducted in 1990 on nine single cells and fifteen 3- to 360-cell modules that encompass six technologies: (Na/S, Zn/Br, Ni/Fe, Ni/Cd, Ni-metal hydride, and lead-acid). These evaluations were performed for the Department of Energy and Electric Power Research Institute. The results provide battery users, developers, and program managers an interim measure of the progress being made in battery R and D programs, a comparison of battery technologies, and a source of basic data for modelling and continuing R and D.
NASA Technical Reports Server (NTRS)
Pirrello, C. J.; Hardin, R. D.; Heckart, M. V.; Brown, K. R.
1971-01-01
The inventory covers free jet and direct connect altitude cells, sea level static thrust stands, sea level test cells with ram air, and propulsion wind tunnels. Free jet altitude cells and propulsion wind tunnels are used for evaluation of complete inlet-engine-exhaust nozzle propulsion systems under simulated flight conditions. These facilities are similar in principal of operation and differ primarily in test section concept. The propulsion wind tunnel provides a closed test section and restrains the flow around the test specimen while the free jet is allowed to expand freely. A chamber of large diameter about the free jet is provided in which desired operating pressure levels may be maintained. Sea level test cells with ram air provide controlled, conditioned air directly to the engine face for performance evaluation at low altitude flight conditions. Direct connect altitude cells provide a means of performance evaluation at simulated conditions of Mach number and altitude with air supplied to the flight altitude conditions. Sea level static thrust stands simply provide an instrumented engine mounting for measuring thrust at zero airspeed. While all of these facilities are used for integrated engine testing, a few provide engine component test capability.
Thurman, Angela John; McDuffie, Andrea; Kover, Sara T.; Hagerman, Randi; Channell, Marie Moore; Mastergeorge, Ann; Abbeduto, Leonard
2014-01-01
The present study evaluated the ability of males with fragile X syndrome (FXS), nonsyndromic autism spectrum disorder (ASD), or typical development to learn new words by using as a cue to the intended referent an emotional reaction indicating a successful (excitement) or unsuccessful (disappointment) search for a novel object. Performance for all groups exceeded chance-levels in both search conditions. In the Successful Search condition, participants with nonsyndromic ASD performed similarly to participants with FXS after controlling for severity of ASD. In the Unsuccessful Search condition, participants with FXS performed significantly worse than participants with nonsyndromic ASD, after controlling for severity of ASD. Predictors of performance in both search conditions differed between the three groups. Theoretical and clinical implications are discussed. PMID:25318904
NASA Technical Reports Server (NTRS)
Shih, K.
1977-01-01
The thermal performance of a flat plate solar collector that uses liquid as the heat transfer medium was investigated under simulated conditions. The test conditions and thermal performance data obtained during the tests are presented in tabular form, as well as in graphs. Data obtained from a time constant test and incident angle modifier test, conducted to determine transient effect and the incident angle effect on the collector, are included.
1988-01-01
under field conditions. Sampling and analytical laboratory activities were performed by Ecology and Environment, Inc., and California Analytical...the proposed AER3 test conditions. All test samples would be obtained onsite by Ecology and Environment, Inc., of Buffalo, New York, and sent to...ensuring its safe operation. Ecology and Environment performed onsite verification sampling. This activity was coordinated with the Huber project team
NASA Astrophysics Data System (ADS)
Man, E. A.; Sera, D.; Mathe, L.; Schaltz, E.; Rosendahl, L.
2016-03-01
Characterization of thermoelectric generators (TEG) is widely discussed and equipment has been built that can perform such analysis. One method is often used to perform such characterization: constant temperature with variable thermal power input. Maximum power point tracking (MPPT) methods for TEG systems are mostly tested under steady-state conditions for different constant input temperatures. However, for most TEG applications, the input temperature gradient changes, exposing the MPPT to variable tracking conditions. An example is the exhaust pipe on hybrid vehicles, for which, because of the intermittent operation of the internal combustion engine, the TEG and its MPPT controller are exposed to a cyclic temperature profile. Furthermore, there are no guidelines on how fast the MPPT must be under such dynamic conditions. In the work discussed in this paper, temperature gradients for TEG integrated in several applications were evaluated; the results showed temperature variation up to 5°C/s for TEG systems. Electrical characterization of a calcium-manganese oxide TEG was performed at steady-state for different input temperatures and a maximum temperature of 401°C. By using electrical data from characterization of the oxide module, a solar array simulator was emulated to perform as a TEG. A trapezoidal temperature profile with different gradients was used on the TEG simulator to evaluate the dynamic MPPT efficiency. It is known that the perturb and observe (P&O) algorithm may have difficulty accurately tracking under rapidly changing conditions. To solve this problem, a compromise must be found between the magnitude of the increment and the sampling frequency of the control algorithm. The standard P&O performance was evaluated experimentally by using different temperature gradients for different MPPT sampling frequencies, and efficiency values are provided for all cases. The results showed that a tracking speed of 2.5 Hz can be successfully implemented on a TEG system to provide ˜95% MPPT efficiency when the input temperature is changing at 5°C/s.
Guy, Joshua H; Deakin, Glen B; Edwards, Andrew M; Miller, Catherine M; Pyne, David B
2015-03-01
Extreme environmental conditions present athletes with diverse challenges; however, not all sporting events are limited by thermoregulatory parameters. The purpose of this leading article is to identify specific instances where hot environmental conditions either compromise or augment performance and, where heat acclimation appears justified, evaluate the effectiveness of pre-event acclimation processes. To identify events likely to be receptive to pre-competition heat adaptation protocols, we clustered and quantified the magnitude of difference in performance of elite athletes competing in International Association of Athletics Federations (IAAF) World Championships (1999-2011) in hot environments (>25 °C) with those in cooler temperate conditions (<25 °C). Athletes in endurance events performed worse in hot conditions (~3 % reduction in performance, Cohen's d > 0.8; large impairment), while in contrast, performance in short-duration sprint events was augmented in the heat compared with temperate conditions (~1 % improvement, Cohen's d > 0.8; large performance gain). As endurance events were identified as compromised by the heat, we evaluated common short-term heat acclimation (≤7 days, STHA) and medium-term heat acclimation (8-14 days, MTHA) protocols. This process identified beneficial effects of heat acclimation on performance using both STHA (2.4 ± 3.5 %) and MTHA protocols (10.2 ± 14.0 %). These effects were differentially greater for MTHA, which also demonstrated larger reductions in both endpoint exercise heart rate (STHA: -3.5 ± 1.8 % vs MTHA: -7.0 ± 1.9 %) and endpoint core temperature (STHA: -0.7 ± 0.7 % vs -0.8 ± 0.3 %). It appears that worthwhile acclimation is achievable for endurance athletes via both short-and medium-length protocols but more is gained using MTHA. Conversely, it is also conceivable that heat acclimation may be counterproductive for sprinters. As high-performance athletes are often time-poor, shorter duration protocols may be of practical preference for endurance athletes where satisfactory outcomes can be achieved.
Simulation and flight test evaluation of head-up-display guidance for harrier approach transitions
NASA Technical Reports Server (NTRS)
Dorr, D. W.; Moralez, E., III; Merrick, V. K.
1994-01-01
Position and speed guidance displays for STOVL aircraft curved, decelerating approaches to hover and vertical landing have been evaluated for their effectiveness in reducing pilot workload and improving performance. The NASA V/STOL Systems Research Aircraft, a modified YAV-8B Harrier prototype, was used to evaluate the displays in flight, whereas the NASA Ames Vertical Motion Simulator was used to extend the flight test results to instrument meteorological conditions (IMC) and to examine performance in various conditions of wind and turbulence. The simulation data showed close correlation with the flight test data, and both demonstrated the feasibility of the displays. With the exception of the hover task in zero visibility, which was level-3, averaged Copper-Harper handling qualities ratings given during simulation were level-2 for both the approach task and the hover task in all conditions. During flight tests in calm and clear conditions, the displays also gave rise to level-2 handling qualities ratings. Pilot opinion showed that the guidance displays would be useful in visual flight, especially at night, as well as in IMC.
NASA Technical Reports Server (NTRS)
Shinoda, Patrick M.
1996-01-01
A full-scale helicopter rotor test was conducted in the NASA Ames 80- by 120-Foot Wind Tunnel with a four-bladed S-76 rotor system. Rotor performance and loads data were obtained over a wide range of rotor shaft angles-of-attack and thrust conditions at tunnel speeds ranging from 0 to 100 kt. The primary objectives of this test were (1) to acquire forward flight rotor performance and loads data for comparison with analytical results; (2) to acquire S-76 forward flight rotor performance data in the 80- by 120-Foot Wind Tunnel to compare with existing full-scale 40- by 80-Foot Wind Tunnel test data that were acquired in 1977; (3) to evaluate the acoustic capability of the 80- by 120- Foot Wind Tunnel for acquiring blade vortex interaction (BVI) noise in the low speed range and compare BVI noise with in-flight test data; and (4) to evaluate the capability of the 80- by 120-Foot Wind Tunnel test section as a hover facility. The secondary objectives were (1) to evaluate rotor inflow and wake effects (variations in tunnel speed, shaft angle, and thrust condition) on wind tunnel test section wall and floor pressures; (2) to establish the criteria for the definition of flow breakdown (condition where wall corrections are no longer valid) for this size rotor and wind tunnel cross-sectional area; and (3) to evaluate the wide-field shadowgraph technique for visualizing full-scale rotor wakes. This data base of rotor performance and loads can be used for analytical and experimental comparison studies for full-scale, four-bladed, fully articulated rotor systems. Rotor performance and structural loads data are presented in this report.
NASA Boeing 737 Aircraft Test Results from 1996 Joint Winter Runway Friction Measurement Program
NASA Technical Reports Server (NTRS)
Yager, Thomas J.
1996-01-01
A description of the joint test program objectives and scope is given together with the performance capability of the NASA Langley B-737 instrumented aircraft. The B-737 test run matrix conducted during the first 8 months of this 5-year program is discussed with a description of the different runway conditions evaluated. Some preliminary test results are discussed concerning the Electronic Recording Decelerometer (ERD) readings and a comparison of B-737 aircraft braking performance for different winter runway conditions. Detailed aircraft parameter time history records, analysis of ground vehicle friction measurements and harmonization with aircraft braking performance, assessment of induced aircraft contaminant drag, and evaluation of the effects of other factors on aircraft/ground vehicle friction performance will be documented in a NASA Technical Report which is being prepared for publication next year.
Oxygen Partial Pressure and Oxygen Concentration Flammability: Can They Be Correlated?
NASA Technical Reports Server (NTRS)
Harper, Susana A.; Juarez, Alfredo; Perez, Horacio, III; Hirsch, David B.; Beeson, Harold D.
2016-01-01
NASA possesses a large quantity of flammability data performed in ISS airlock (30% Oxygen 526mmHg) and ISS cabin (24.1% Oxygen 760 mmHg) conditions. As new programs develop, other oxygen and pressure conditions emerge. In an effort to apply existing data, the question arises: Do equivalent oxygen partial pressures perform similarly with respect to flammability? This paper evaluates how material flammability performance is impacted from both the Maximum Oxygen Concentration (MOC) and Maximum Total Pressures (MTP) perspectives. From these studies, oxygen partial pressures can be compared for both the MOC and MTP methods to determine the role of partial pressure in material flammability. This evaluation also assesses the influence of other variables on flammability performance. The findings presented in this paper suggest flammability is more dependent on oxygen concentration than equivalent partial pressure.
The use of vestibular models for design and evaluation of flight simulator motion
NASA Technical Reports Server (NTRS)
Bussolari, Steven R.; Young, Laurence R.; Lee, Alfred T.
1989-01-01
Quantitative models for the dynamics of the human vestibular system are applied to the design and evaluation of flight simulator platform motion. An optimal simulator motion control algorithm is generated to minimize the vector difference between perceived spatial orientation estimated in flight and in simulation. The motion controller has been implemented on the Vertical Motion Simulator at NASA Ames Research Center and evaluated experimentally through measurement of pilot performance and subjective rating during VTOL aircraft simulation. In general, pilot performance in a longitudinal tracking task (formation flight) did not appear to be sensitive to variations in platform motion condition as long as motion was present. However, pilot assessment of motion fidelity by means of a rating scale designed for this purpose, were sensitive to motion controller design. Platform motion generated with the optimal motion controller was found to be generally equivalent to that generated by conventional linear crossfeed washout. The vestibular models are used to evaluate the motion fidelity of transport category aircraft (Boeing 727) simulation in a pilot performance and simulator acceptability study at the Man-Vehicle Systems Research Facility at NASA Ames Research Center. Eighteen airline pilots, currently flying B-727, were given a series of flight scenarios in the simulator under various conditions of simulator motion. The scenarios were chosen to reflect the flight maneuvers that these pilots might expect to be given during a routine pilot proficiency check. Pilot performance and subjective rating of simulator fidelity was relatively insensitive to the motion condition, despite large differences in the amplitude of motion provided. This lack of sensitivity may be explained by means of the vestibular models, which predict little difference in the modeled motion sensations of the pilots when different motion conditions are imposed.
The development of an advanced generic solar dynamic heat receiver thermal model
NASA Technical Reports Server (NTRS)
Wu, Y. C.; Roschke, E. J.; Kohout, L.
1988-01-01
An advanced generic solar dynamic heat receiver thermal model under development which can analyze both orbital transient and orbital average conditions is discussed. This model can be used to study advanced receiver concepts, evaluate receiver concepts under development, analyze receiver thermal characteristics under various operational conditions, and evaluate solar dynamic system thermal performances in various orbit conditions. The model and the basic considerations that led to its creation are described, and results based on a set of baseline orbit, configuration, and operational conditions are presented to demonstrate the working of the receiver model.
Durability and smart condition assessment of ultra-high performance concrete in cold climates.
DOT National Transportation Integrated Search
2016-12-31
The goals of this study were to develop ecological ultra-high performance concrete (UHPC) with local materials and supplementary cementitious materials and to evaluate the long-term performance of UHPC in cold climates using effective mechanical test...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chambon, Paul H.; Deter, Dean D.
2016-07-01
xiii ABSTRACT The goal of this project is to develop and evaluate powertrain test procedures that can accurately simulate real-world operating conditions, and to determine greenhouse gas (GHG) emissions of advanced medium- and heavy-duty engine and vehicle technologies. ORNL used their Vehicle System Integration Laboratory to evaluate test procedures on a stand-alone engine as well as two powertrains. Those components where subjected to various drive cycles and vehicle conditions to evaluate the validity of the results over a broad range of test conditions. Overall, more than 1000 tests were performed. The data are compiled and analyzed in this report.
Key results of battery performance and life tests at Argonne National Laboratory
NASA Astrophysics Data System (ADS)
Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.
1991-12-01
Advanced battery technology evaluations are performed under simulated electric vehicle operating conditions at Argonne National Laboratory's & Diagnostic Laboratory (ADL). The ADL provide a common basis for both performance characterization and life evaluation with unbiased application of tests and analyses. This paper summarizes the performance characterizations and life evaluations conducted in 1991 on twelve single cells and eight 3- to 360-cell modules that encompass six battery technologies (Na/S, Li/MS, Ni/MH, Zn/Br, Ni/Fe, and Pb-Acid). These evaluations were performed for the Department of Energy, Office of Transportation Technologies, Electric and Hybrid Propulsion Division. The results measure progress in battery R & D programs, compare battery technologies, and provide basic data for modeling and continuing R & D to battery users, developers, and program managers.
Ning, Zhi; Ye, Sheng; Sun, Li; Yang, Fenhuan; Wong, Ka Chun; Westerdahl, Dane; Louie, Peter K. K.
2018-01-01
The increasing applications of low-cost air sensors promises more convenient and cost-effective systems for air monitoring in many places and under many conditions. However, the data quality from such systems has not been fully characterized and may not meet user expectations in research and regulatory uses, or for use in citizen science. In our study, electrochemical sensors (Alphasense B4 series) for carbon monoxide (CO), nitric oxide (NO), nitrogen dioxide (NO2), and oxidants (Ox) were evaluated under controlled laboratory conditions to identify the influencing factors and quantify their relation with sensor outputs. Based on the laboratory tests, we developed different correction methods to compensate for the impact of ambient conditions. Further, the sensors were assembled into a monitoring system and tested in ambient conditions in Hong Kong side-by-side with regulatory reference monitors, and data from these tests were used to evaluate the performance of the models, to refine them, and validate their applicability in variable ambient conditions in the field. The more comprehensive correction models demonstrated enhanced performance when compared with uncorrected data. One over-arching observation of this study is that the low-cost sensors may promise excellent sensitivity and performance, but it is essential for users to understand and account for several key factors that may strongly affect the nature of sensor data. In this paper, we also evaluated factors of multi-month stability, temperature, and humidity, and considered the interaction of oxidant gases NO2 and ozone on a newly introduced oxidant sensor. PMID:29360749
Wei, Peng; Ning, Zhi; Ye, Sheng; Sun, Li; Yang, Fenhuan; Wong, Ka Chun; Westerdahl, Dane; Louie, Peter K K
2018-01-23
The increasing applications of low-cost air sensors promises more convenient and cost-effective systems for air monitoring in many places and under many conditions. However, the data quality from such systems has not been fully characterized and may not meet user expectations in research and regulatory uses, or for use in citizen science. In our study, electrochemical sensors (Alphasense B4 series) for carbon monoxide (CO), nitric oxide (NO), nitrogen dioxide (NO₂), and oxidants (O x ) were evaluated under controlled laboratory conditions to identify the influencing factors and quantify their relation with sensor outputs. Based on the laboratory tests, we developed different correction methods to compensate for the impact of ambient conditions. Further, the sensors were assembled into a monitoring system and tested in ambient conditions in Hong Kong side-by-side with regulatory reference monitors, and data from these tests were used to evaluate the performance of the models, to refine them, and validate their applicability in variable ambient conditions in the field. The more comprehensive correction models demonstrated enhanced performance when compared with uncorrected data. One over-arching observation of this study is that the low-cost sensors may promise excellent sensitivity and performance, but it is essential for users to understand and account for several key factors that may strongly affect the nature of sensor data. In this paper, we also evaluated factors of multi-month stability, temperature, and humidity, and considered the interaction of oxidant gases NO₂ and ozone on a newly introduced oxidant sensor.
34 CFR 75.590 - Evaluation by the recipient.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 34 Education 1 2010-07-01 2010-07-01 false Evaluation by the recipient. 75.590 Section 75.590 Education Office of the Secretary, Department of Education DIRECT GRANT PROGRAMS What Conditions Must Be Met by a Grantee? Evaluation § 75.590 Evaluation by the recipient. A recipient shall submit a performance...
Abikoff, H; Courtney, M E; Szeibel, P J; Koplewicz, H S
1996-05-01
This study evaluated the impact of extra-task stimulation on the academic task performance of children with attention-deficit/hyperactivity disorder (ADHD). Twenty boys with ADHD and 20 nondisabled boys worked on an arithmetic task during high stimulation (music), low stimulation (speech), and no stimulation (silence). The music "distractors" were individualized for each child, and the arithmetic problems were at each child's ability level. A significant Group x Condition interaction was found for number of correct answers. Specifically, the nondisabled youngsters performed similarly under all three auditory conditions. In contrast, the children with ADHD did significantly better under the music condition than speech or silence conditions. However, a significant Group x Order interaction indicated that arithmetic performance was enhanced only for those children with ADHD who received music as the first condition. The facilitative effects of salient auditory stimulation on the arithmetic performance of the children with ADHD provide some support for the underarousal/optimal stimulation theory of ADHD.
Economic Evaluation of Single-Family-Residence Solar-Energy Installation
NASA Technical Reports Server (NTRS)
1982-01-01
Long-term economic performance of a commercial solar-energy system was analyzed and used to predict economic performance at four additional sites. Analysis described in report was done to demonstrate viability of design over a broad range of environmental/economic conditions. Report contains graphs and tables that present evaluation procedure and results. Also contains appendixes that aid in understanding methods used.
NASA Technical Reports Server (NTRS)
Byers, M. S.
1973-01-01
Analyses for Experiment M555, Gallium Arsenide Single Crystal Growth (MSFC), to be used for evaluating the performance of the Skylab corollary experiments under preflight, inflight, and post-flight conditions are presented. Experiment contingency plan workaround procedure and malfunction analyses are presented in order to assist in making the experiment operationally successful.
NASA Technical Reports Server (NTRS)
Purushotham, K. S.
1973-01-01
This appendix contains a series of analyses for Experiment M487, Habitability/ Crew Quarters (MSFC), to be used for evaluating the performance of the Skylab corollary experiments under preflight, inflight, and post flight conditions. Experiment contingency plan workaround procedure and malfunction analyses are presented in order to assist in making the experiment operationally successful.
Bonnyaud, Céline; Pradon, Didier; Vuillerme, Nicolas; Bensmail, Djamel; Roche, Nicolas
2015-01-01
Background The timed up and go test (TUG) is a functional test which is increasingly used to evaluate patients with stroke. The outcome measured is usually global TUG performance-time. Assessment of spatiotemporal and kinematic parameters during the Oriented gait and Turn sub-tasks of the TUG would provide a better understanding of the mechanisms underlying patients’ performance and therefore may help to guide rehabilitation. The aim of this study was thus to determine the spatiotemporal and kinematic parameters which were most related to the walking and turning sub-tasks of TUG performance in stroke patients. Methods 29 stroke patients carried out the TUG test which was recorded using an optoelectronic system in two conditions: spontaneous and standardized condition (standardized foot position and instructed to turn towards the paretic side). They also underwent a clinical assessment. Stepwise regression was used to determine the parameters most related to Oriented gait and Turn sub-tasks. Relationships between explanatory parameters of Oriented gait and Turn performance and clinical scales were evaluated using Spearman correlations. Results Step length and cadence explained 82% to 95% of the variance for the walking sub-tasks in both conditions. Percentage single support phase and contralateral swing phase (depending on the condition) respectively explained 27% and 56% of the variance during the turning sub-task in the spontaneous and standardized conditions. Discussion and Conclusion Step length, cadence, percentage of paretic single support phase and non-paretic swing phase, as well as dynamic stability were the main parameters related to TUG performance and they should be targeted in rehabilitation. PMID:26091555
Active eye fixation performance in 940 young men: effects of IQ, schizotypy, anxiety and depression.
Smyrnis, N; Kattoulas, E; Evdokimidis, I; Stefanis, N C; Avramopoulos, D; Pantes, G; Theleritis, C; Stefanis, C N
2004-05-01
A total of 940 young men performed a task in which they actively maintained fixation for 50 s in three conditions: a). on a visual target, b). on a visual target while distracting targets appeared briefly on the periphery and c). with no visual target present. The same individuals completed psychometric evaluation tests measuring IQ, schizotypy and current state-dependent psychopathology. The proportion of fixation time decreased and saccade frequency increased in condition b compared wih condition a, and sequentially in condition c compared with condition b. A trend towards a decrease in proportion of fixation time and increase in saccade frequency was found as the subjects maintained fixation during the task and this time-dependent deterioration of performance was again most pronounced in condition c, less so in condition b and absent in condition a. Psychometric test scores were significantly correlated with fixation performance in the population. Worse performance in all three fixation conditions was observed for individuals with lower IQ scores. A deterioration of fixation performance with time in condition b was correlated with disorganization characteristics of schizotypy, suggesting that these individuals had difficulty maintaining active fixation in the presence of increased inhibitory load. A connection of such a difficulty with the frontal lobes and their role in the control of voluntary inhibitory functions is discussed.
NASA Technical Reports Server (NTRS)
Brown, S. C.; Hardy, G. H.; Hindson, W. S.
1983-01-01
As part of a comprehensive flight-test program of STOL operating systems for the terminal area, an automatic landing system was developed and evaluated for a light wing loading turboprop aircraft. The aircraft utilized an onboard advanced digital avionics system. Flight tests were conducted at a facility that included a STOL runway site with a microwave landing system. Longitudinal flight-test results were presented and compared with available (basically CTOL) criteria. These comparisons were augmented by results from a comprehensive simulation of the controlled aircraft which included representations of navigation errors that were encountered in flight and atmospheric disturbances. Acceptable performance on final approach and at touchdown was achieved by the autoland (automatic landing) system for the moderate winds and turbulence conditions encountered in flight. However, some touchdown performance goals were marginally achieved, and simulation results suggested that difficulties could be encountered in the presence of more extreme atmospheric conditions. Suggestions were made for improving performance under those more extreme conditions.
NASA Technical Reports Server (NTRS)
Chung, William W.; Linse, Dennis J.; Alaverdi, Omeed; Ifarraguerri, Carlos; Seifert, Scott C.; Salvano, Dan; Calender, Dale
2012-01-01
This study investigates the effects of two technical enablers: Automatic Dependent Surveillance - Broadcast (ADS-B) and digital datalink communication, of the Federal Aviation Administration s Next Generation Air Transportation System (NextGen) under two separation assurance (SA) system architectures: ground-based SA and airborne SA, on overall separation assurance performance. Datalink performance such as successful reception probability in both surveillance and communication messages, and surveillance accuracy are examined in various operational conditions. Required SA performance is evaluated as a function of subsystem performance, using availability, continuity, and integrity metrics to establish overall required separation assurance performance, under normal and off-nominal conditions.
Final postflight hardware evaluation report RSRM-28 (STS-53)
NASA Technical Reports Server (NTRS)
Starrett, William David, Jr.
1993-01-01
The final report for the Clearfield disassembly evaluation and a continuation of the KSC postflight assessment for the RSRM-28 (STS-53) RSRM flight set is presented. All observed hardware conditions were documented on PFOR's and are included in Appendices A through C. Appendices D and E contain the measurements and safety factor data for the nozzle and insulation components. This report, along with the KSC Ten-Day Postflight Hardware Evaluation Report (TWR-64215), represents a summary of the RSRM-28 hardware evaluation. The as-flown hardware configuration is documented in TWR-63638. Disassembly evaluation photograph numbers are logged in TWA-1989. The RSRM-28 flight set disassembly evaluations described were performed at the RSRM Refurbishment Facility in Clearfield, Utah. The final factory joint demate occurred on July 15, 1993. Additional time was required to perform the evaluation of the stiffener rings per special issue 4.1.5.2 because of the washout schedule. The release of this report was after completion of all special issues per program management direction. Detailed evaluations were performed in accordance with the Clearfield PEEP, TWR-50051, Revision A. All observations were compared against limits that are also defined in the PEEP. These limits outline the criteria for categorizing the observations as acceptable, reportable, or critical. Hardware conditions that were unexpected and/or determined to be reportable or critical were evaluated by the applicable team and tracked through the PFAR system.
NASA Technical Reports Server (NTRS)
Yager, Thomas J.; Vogler, William A.; Baldasare, Paul
1990-01-01
Tests with specially instrumented NASA Boeing 737 and 727 aircraft together with several different ground friction measuring devices were conducted for a variety of runway surface types and conditions. These tests are part of joint FAA/NASA Aircraft/Ground Vehicle Runway Friction Program aimed at obtaining a better understanding of aircraft ground handling performance under adverse weather conditions and defining relationships between aircraft and ground vehicle tire friction measurements. Aircraft braking performance on dry, wet, snow and ice-covered runway conditions is discussed as well as ground vehicle friction data obtained under similar runway conditions. For a given contaminated runway surface condition, the correlation between ground vehicles and aircraft friction data is identified. The influence of major test parameters on friction measurements such as speed, test tire characteristics, type and amount of surface contaminant, and ambient temperature are discussed. The effect of surface type on wet friction levels is also evaluated from comparative data collected on grooved and ungrooved concrete and asphalt surfaces.
Stephenson, D J; Lillquist, D R
2001-04-01
Occupational hygienists perform air sampling to characterize airborne contaminant emissions, assess occupational exposures, and establish allowable workplace airborne exposure concentrations. To perform these air sampling applications, occupational hygienists often compare an airborne exposure concentration to a corresponding American Conference of Governmental Industrial Hygienists (ACGIH) threshold limit value (TLV) or an Occupational Safety and Health Administration (OSHA) permissible exposure limit (PEL). To perform such comparisons, one must understand the physiological assumptions used to establish these occupational exposure limits, the relationship between a workplace airborne exposure concentration and its associated TLV or PEL, and the effect of temperature and pressure on the performance of an accurate compliance evaluation. This article illustrates the correct procedure for performing compliance evaluations using airborne exposure concentrations expressed in both parts per million and milligrams per cubic meter. In so doing, a brief discussion is given on the physiological assumptions used to establish TLVs and PELs. It is further shown how an accurate compliance evaluation is fundamentally based on comparison of a measured work site exposure dose (derived from the sampling site exposure concentration estimate) to an estimated acceptable exposure dose (derived from the occupational exposure limit concentration). In addition, this article correctly illustrates the effect that atmospheric temperature and pressure have on airborne exposure concentrations and the eventual performance of a compliance evaluation. This article also reveals that under fairly moderate conditions of temperature and pressure, 30 degrees C and 670 torr, a misunderstanding of how varying atmospheric conditions affect concentration values can lead to a 15 percent error in assessing compliance.
Development of design information for molecular-sieve type regenerative CO2-removal systems
NASA Technical Reports Server (NTRS)
Wright, R. M.; Ruder, J. M.; Dunn, V. B.; Hwang, K. C.
1973-01-01
Experimental and analytic studies were conducted with molecular sieve sorbents to provide basic design information, and to develop a system design technique for regenerable CO2-removal systems for manned spacecraft. Single sorbate equilibrium data were obtained over a wide range of conditions for CO2, water, nitrogen, and oxygen on several molecular sieve and silica gel sorbents. The coadsorption of CO2 with water preloads, and with oxygen and nitrogen was experimentally evaluated. Mass-transfer, and some limited heat-transfer performance evaluations were accomplished under representative operating conditions, including the coadsorption of CO2 and water. CO2-removal system performance prediction capability was derived.
Similarity constraints in testing of cooled engine parts
NASA Technical Reports Server (NTRS)
Colladay, R. S.; Stepka, F. S.
1974-01-01
A study is made of the effect of testing cooled parts of current and advanced gas turbine engines at the reduced temperature and pressure conditions which maintain similarity with the engine environment. Some of the problems facing the experimentalist in evaluating heat transfer and aerodynamic performance when hardware is tested at conditions other than the actual engine environment are considered. Low temperature and pressure test environments can simulate the performance of actual size prototype engine hardware within the tolerance of experimental accuracy if appropriate similarity conditions are satisfied. Failure to adhere to these similarity constraints because of test facility limitations or other reasons, can result in a number of serious errors in projecting the performance of test hardware to engine conditions.
Instrumentation Performance During the TMI-2 Accident
NASA Astrophysics Data System (ADS)
Rempe, Joy L.; Knudson, Darrell L.
2014-08-01
The accident at the Three Mile Island Unit 2 (TMI-2) reactor provided a unique opportunity to evaluate sensors exposed to severe accident conditions. The loss of coolant and the hydrogen combustion that occurred during this accident exposed instrumentation to harsh conditions, including direct radiation, radioactive contamination, and high humidity with elevated temperatures and pressures. As part of a program initiated by the Department of Energy Office of Nuclear Energy (DOE-NE), a review was completed to gain insights from prior TMI-2 sensor survivability and data qualification efforts. This new effort focused upon a set of sensors that provided critical data to TMI-2 operators for assessing the condition of the plant and the effects of mitigating actions taken by these operators. In addition, the effort considered sensors providing data required for subsequent accident simulations. Over 100 references related to instrumentation performance and post-accident evaluations of TMI-2 sensors and measurements were reviewed. Insights gained from this review are summarized within this paper. As noted within this paper, several techniques were invoked in the TMI-2 post-accident program to evaluate sensor survivability status and data qualification, including comparisons with data from other sensors, analytical calculations, laboratory testing, and comparisons with sensors subjected to similar conditions in large-scale integral tests and with sensors that were similar in design but more easily removed from the TMI-2 plant for evaluations. Conclusions from this review provide important insights related to sensor survivability and enhancement options for improving sensor performance. In addition, this paper provides recommendations related to sensor survivability and the data evaluation process that could be implemented in upcoming Fukushima Daiichi recovery efforts.
Caduff, A; Dewarrat, F; Talary, M; Stalder, G; Heinemann, L; Feldman, Yu
2006-12-15
The aim of this work was to evaluate the performance of a novel non-invasive continuous glucose-monitoring system based on impedance spectroscopy (IS) in patients with diabetes. Ten patients with type 1 diabetes (mean+/-S.D., age 28+/-8 years, BMI 24.2+/-3.2 kg/m(2) and HbA(1C) 7.3+/-1.6%) and five with type 2 diabetes (age 61+/-8 years, BMI 27.5+/-3.2 kg/m(2) and HbA(1C) 8.3+/-1.8%) took part in this study, which comprised a glucose clamp experiment followed by a 7-day outpatient evaluation. The measurements obtained by the NI-CGMD and the reference blood glucose-measuring techniques were evaluated using retrospective data evaluation procedures. Under less controlled outpatient conditions a correlation coefficient of r=0.640 and a standard error of prediction (SEP) of 45 mg dl(-1) with a total of 590 paired glucose measurements was found (versus r=0.926 and a SEP of 26 mg dl(-1) under controlled conditions). Clark error grid analyses (EGA) showed 56% of all values in zone A, 37% in B and 7% in C-E. In conclusion, these results indicate that IS in the used technical setting allows retrospective, continuous and truly non-invasive glucose monitoring under defined conditions for patients with diabetes. Technical advances and developments are needed to expand on this concept to bring the results from the outpatient study closer to those in the experimental section of the study. Further studies will not only help to evaluate the performance and limitations of using such a technique for non non-invasive glucose monitoring but also help to verify technical extensions towards a IS-based concept that offers improved performance under real life operating conditions.
Evaluation of Candidate Millimeter Wave Sensors for Synthetic Vision
NASA Technical Reports Server (NTRS)
Alexander, Neal T.; Hudson, Brian H.; Echard, Jim D.
1994-01-01
The goal of the Synthetic Vision Technology Demonstration Program was to demonstrate and document the capabilities of current technologies to achieve safe aircraft landing, take off, and ground operation in very low visibility conditions. Two of the major thrusts of the program were (1) sensor evaluation in measured weather conditions on a tower overlooking an unused airfield and (2) flight testing of sensor and pilot performance via a prototype system. The presentation first briefly addresses the overall technology thrusts and goals of the program and provides a summary of MMW sensor tower-test and flight-test data collection efforts. Data analysis and calibration procedures for both the tower tests and flight tests are presented. The remainder of the presentation addresses the MMW sensor flight-test evaluation results, including the processing approach for determination of various performance metrics (e.g., contrast, sharpness, and variability). The variation of the very important contrast metric in adverse weather conditions is described. Design trade-off considerations for Synthetic Vision MMW sensors are presented.
Perceptual evaluation of visual alerts in surveillance videos
NASA Astrophysics Data System (ADS)
Rogowitz, Bernice E.; Topkara, Mercan; Pfeiffer, William; Hampapur, Arun
2015-03-01
Visual alerts are commonly used in video monitoring and surveillance systems to mark events, presumably making them more salient to human observers. Surprisingly, the effectiveness of computer-generated alerts in improving human performance has not been widely studied. To address this gap, we have developed a tool for simulating different alert parameters in a realistic visual monitoring situation, and have measured human detection performance under conditions that emulated different set-points in a surveillance algorithm. In the High-Sensitivity condition, the simulated alerts identified 100% of the events with many false alarms. In the Lower-Sensitivity condition, the simulated alerts correctly identified 70% of the targets, with fewer false alarms. In the control condition, no simulated alerts were provided. To explore the effects of learning, subjects performed these tasks in three sessions, on separate days, in a counterbalanced, within subject design. We explore these results within the context of cognitive models of human attention and learning. We found that human observers were more likely to respond to events when marked by a visual alert. Learning played a major role in the two alert conditions. In the first session, observers generated almost twice as many False Alarms as in the No-Alert condition, as the observers responded pre-attentively to the computer-generated false alarms. However, this rate dropped equally dramatically in later sessions, as observers learned to discount the false cues. Highest observer Precision, Hits/(Hits + False Alarms), was achieved in the High Sensitivity condition, but only after training. The successful evaluation of surveillance systems depends on understanding human attention and performance.
ANN based Performance Evaluation of BDI for Condition Monitoring of Induction Motor Bearings
NASA Astrophysics Data System (ADS)
Patel, Raj Kumar; Giri, V. K.
2017-06-01
One of the critical parts in rotating machines is bearings and most of the failure arises from the defective bearings. Bearing failure leads to failure of a machine and the unpredicted productivity loss in the performance. Therefore, bearing fault detection and prognosis is an integral part of the preventive maintenance procedures. In this paper vibration signal for four conditions of a deep groove ball bearing; normal (N), inner race defect (IRD), ball defect (BD) and outer race defect (ORD) were acquired from a customized bearing test rig, under four different conditions and three different fault sizes. Two approaches have been opted for statistical feature extraction from the vibration signal. In the first approach, raw signal is used for statistical feature extraction and in the second approach statistical features extracted are based on bearing damage index (BDI). The proposed BDI technique uses wavelet packet node energy coefficients analysis method. Both the features are used as inputs to an ANN classifier to evaluate its performance. A comparison of ANN performance is made based on raw vibration data and data chosen by using BDI. The ANN performance has been found to be fairly higher when BDI based signals were used as inputs to the classifier.
Auer, E T; Bernstein, L E; Coulter, D C
1998-10-01
Four experiments were performed to evaluate a new wearable vibrotactile speech perception aid that extracts fundamental frequency (F0) and displays the extracted F0 as a single-channel temporal or an eight-channel spatio-temporal stimulus. Specifically, we investigated the perception of intonation (i.e., question versus statement) and emphatic stress (i.e., stress on the first, second, or third word) under Visual-Alone (VA), Visual-Tactile (VT), and Tactile-Alone (TA) conditions and compared performance using the temporal and spatio-temporal vibrotactile display. Subjects were adults with normal hearing in experiments I-III and adults with severe to profound hearing impairments in experiment IV. Both versions of the vibrotactile speech perception aid successfully conveyed intonation. Vibrotactile stress information was successfully conveyed, but vibrotactile stress information did not enhance performance in VT conditions beyond performance in VA conditions. In experiment III, which involved only intonation identification, a reliable advantage for the spatio-temporal display was obtained. Differences between subject groups were obtained for intonation identification, with more accurate VT performance by those with normal hearing. Possible effects of long-term hearing status are discussed.
NASA Technical Reports Server (NTRS)
Morello, S. A.; Knox, C. E.; Steinmetz, G. G.
1977-01-01
The results of a flight evaluation of two electronic display formats for the approach to landing under instrument conditions are presented. The evaluation was conducted for a base-line electronic display format and for the same format with runway symbology and track information added. The evaluation was conducted during 3 deg, manual straight-in approaches with and without initial localizer offsets. Flight path tracking performance data and pilot subjective comments were examined with regard to the pilot's ability to capture and maintain localizer and glide slope by using both display formats.
DI Cagno, Alessandra; Iuliano, Enzo; Fiorilli, Giovanni; Aquino, Giovanna; Giombini, Arrigo; Menotti, Federica; Tsopani, Despina; Calcagno, Giuseppe
2016-10-01
The aim of this study was to evaluate the effects of rhythmical and extra-rhythmical qualities of music on the heart rate (HR) and rates of perceived exertion (RPE), during sub-maximal stationary bike activity. HR of 28 female adult participants was monitored during 3 session of physical activity, performed under 3 different conditions: Hi-BPM (music with 150-170 BPM), RHYTHM (rhythmical qualities only of Hi-BPM condition) and control condition without music (CONTROL). Four parameters were analyzed: the highest HR value (High-HR), High-HR minus starting HR (∆HR), time to reach the 75% of Maximal HR (MHR) (TimeTo75%) and time over 75% MHR (TimeOver75%). HR trend analysis was performed to evaluate differences among the three conditions. OMNI-Cycle Scale was administered to evaluate RPE. MANOVA showed significant differences between the three conditions in TimeTo75%, ∆HR (P<0.01) and TimeOver75% (P<0.05). In RHYTHM and CONTROL conditions after reaching 75% MHR, the HR increase were significantly lower than Hi-BPM (P<0.01). No significant differences were found in OMNI-Cycle Scale scores of Hi-BPM and RHYTHM whereas RPE was significantly higher in CONTROL condition (P<0.05). Hi-BPM and RHYTHM music allowed a faster reaching of the aerobic training zone compared to CONTROL conditions. Nevertheless, after 75% MHR, extra-rhythmical qualities are necessary to maintain or to increase the working HR levels.
How to determine an optimal threshold to classify real-time crash-prone traffic conditions?
Yang, Kui; Yu, Rongjie; Wang, Xuesong; Quddus, Mohammed; Xue, Lifang
2018-08-01
One of the proactive approaches in reducing traffic crashes is to identify hazardous traffic conditions that may lead to a traffic crash, known as real-time crash prediction. Threshold selection is one of the essential steps of real-time crash prediction. And it provides the cut-off point for the posterior probability which is used to separate potential crash warnings against normal traffic conditions, after the outcome of the probability of a crash occurring given a specific traffic condition on the basis of crash risk evaluation models. There is however a dearth of research that focuses on how to effectively determine an optimal threshold. And only when discussing the predictive performance of the models, a few studies utilized subjective methods to choose the threshold. The subjective methods cannot automatically identify the optimal thresholds in different traffic and weather conditions in real application. Thus, a theoretical method to select the threshold value is necessary for the sake of avoiding subjective judgments. The purpose of this study is to provide a theoretical method for automatically identifying the optimal threshold. Considering the random effects of variable factors across all roadway segments, the mixed logit model was utilized to develop the crash risk evaluation model and further evaluate the crash risk. Cross-entropy, between-class variance and other theories were employed and investigated to empirically identify the optimal threshold. And K-fold cross-validation was used to validate the performance of proposed threshold selection methods with the help of several evaluation criteria. The results indicate that (i) the mixed logit model can obtain a good performance; (ii) the classification performance of the threshold selected by the minimum cross-entropy method outperforms the other methods according to the criteria. This method can be well-behaved to automatically identify thresholds in crash prediction, by minimizing the cross entropy between the original dataset with continuous probability of a crash occurring and the binarized dataset after using the thresholds to separate potential crash warnings against normal traffic conditions. Copyright © 2018 Elsevier Ltd. All rights reserved.
77 FR 34355 - Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-11
..., training conditions, technological environment, types of jobs and tasks, types of programs needed, and... information on organizational goals (e.g., desired performance), training conditions (e.g., technological environment), specific jobs and tasks, types of programs needed, and target audience. Evaluation respondents...
Conductor gestures influence evaluations of ensemble performance
Morrison, Steven J.; Price, Harry E.; Smedley, Eric M.; Meals, Cory D.
2014-01-01
Previous research has found that listener evaluations of ensemble performances vary depending on the expressivity of the conductor’s gestures, even when performances are otherwise identical. It was the purpose of the present study to test whether this effect of visual information was evident in the evaluation of specific aspects of ensemble performance: articulation and dynamics. We constructed a set of 32 music performances that combined auditory and visual information and were designed to feature a high degree of contrast along one of two target characteristics: articulation and dynamics. We paired each of four music excerpts recorded by a chamber ensemble in both a high- and low-contrast condition with video of four conductors demonstrating high- and low-contrast gesture specifically appropriate to either articulation or dynamics. Using one of two equivalent test forms, college music majors and non-majors (N = 285) viewed sixteen 30 s performances and evaluated the quality of the ensemble’s articulation, dynamics, technique, and tempo along with overall expressivity. Results showed significantly higher evaluations for performances featuring high rather than low conducting expressivity regardless of the ensemble’s performance quality. Evaluations for both articulation and dynamics were strongly and positively correlated with evaluations of overall ensemble expressivity. PMID:25104944
Sabatini, Angelo Maria
2011-01-01
In this paper we present a quaternion-based Extended Kalman Filter (EKF) for estimating the three-dimensional orientation of a rigid body. The EKF exploits the measurements from an Inertial Measurement Unit (IMU) that is integrated with a tri-axial magnetic sensor. Magnetic disturbances and gyro bias errors are modeled and compensated by including them in the filter state vector. We employ the observability rank criterion based on Lie derivatives to verify the conditions under which the nonlinear system that describes the process of motion tracking by the IMU is observable, namely it may provide sufficient information for performing the estimation task with bounded estimation errors. The observability conditions are that the magnetic field, perturbed by first-order Gauss-Markov magnetic variations, and the gravity vector are not collinear and that the IMU is subject to some angular motions. Computer simulations and experimental testing are presented to evaluate the algorithm performance, including when the observability conditions are critical. PMID:22163689
Chang, Young-Soo; Hong, Sung Hwa; Kim, Eun Yeon; Choi, Ji Eun; Chung, Won-Ho; Cho, Yang-Sun; Moon, Il Joon
2018-05-18
Despite recent advancement in the prediction of cochlear implant outcome, the benefit of bilateral procedures compared to bimodal stimulation and how we predict speech perception outcomes of sequential bilateral cochlear implant based on bimodal auditory performance in children remain unclear. This investigation was performed: (1) to determine the benefit of sequential bilateral cochlear implant and (2) to identify the associated factors for the outcome of sequential bilateral cochlear implant. Observational and retrospective study. We retrospectively analyzed 29 patients with sequential cochlear implant following bimodal-fitting condition. Audiological evaluations were performed; the categories of auditory performance scores, speech perception with monosyllable and disyllables words, and the Korean version of Ling. Audiological evaluations were performed before sequential cochlear implant with the bimodal fitting condition (CI1+HA) and one year after the sequential cochlear implant with bilateral cochlear implant condition (CI1+CI2). The good Performance Group (GP) was defined as follows; 90% or higher in monosyllable and bisyllable tests with auditory-only condition or 20% or higher improvement of the scores with CI1+CI2. Age at first implantation, inter-implant interval, categories of auditory performance score, and various comorbidities were analyzed by logistic regression analysis. Compared to the CI1+HA, CI1+CI2 provided significant benefit in categories of auditory performance, speech perception, and Korean version of Ling results. Preoperative categories of auditory performance scores were the only associated factor for being GP (odds ratio=4.38, 95% confidence interval - 95%=1.07-17.93, p=0.04). The children with limited language development in bimodal condition should be considered as the sequential bilateral cochlear implant and preoperative categories of auditory performance score could be used as the predictor in speech perception after sequential cochlear implant. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
TMI-2 - A Case Study for PWR Instrumentation Performance during a Severe Accident
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joy L. Rempe; Darrell L. Knudson
2013-03-01
The accident at the Three Mile Island Unit 2 (TMI-2) reactor provided a unique opportunity to evaluate sensors exposed to severe accident conditions. Conditions associated with the release of coolant and the hydrogen burn that occurred during this accident exposed instrumentation to harsh conditions, including direct radiation, radioactive contamination, and high humidity with elevated temperatures and pressures. As part of a program initiated in 2012 by the Department of Energy Office of Nuclear Energy (DOE-NE), a review was completed to gain insights from prior TMI-2 sensor survivability and data qualification efforts. This new effort focussed upon a set of sensorsmore » that provided critical data to TMI-2 operators for assessing the condition of the plant and the effects of mitigating actions taken by these operators. In addition, the effort considered sensors providing data required for subsequent accident simulations. Over 100 references related to instrumentation performance and post-accident evaluations of TMI-2 sensors and measurements were reviewed. Insights gained from this review are summarized within this report. For each sensor, a description is provided with the measured data and conclusions related to the sensor’s survivability, and the basis for conclusions about its survivability. As noted within this document, several techniques were invoked in the TMI-2 post-accident evaluation program to assess sensor status, including comparisons with data from other sensors, analytical calculations, laboratory testing, and comparisons with sensors subjected to similar conditions in large-scale integral tests and with sensors that were similar in design but more easily removed from the TMI-2 plant for evaluations. Conclusions from this review provide important insights related to sensor survivability and enhancement options for improving sensor performance. In addition, this document provides recommendations related to the sensor survivability and data evaluation process that could be implemented in upcoming Fukushima Daiichi recovery efforts.« less
TMI-2 - A Case Study for PWR Instrumentation Performance during a Severe Accident
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joy L. Rempe; Darrell L. Knudson
2014-05-01
The accident at the Three Mile Island Unit 2 (TMI-2) reactor provided a unique opportunity to evaluate sensors exposed to severe accident conditions. Conditions associated with the release of coolant and the hydrogen burn that occurred during this accident exposed instrumentation to harsh conditions, including direct radiation, radioactive contamination, and high humidity with elevated temperatures and pressures. As part of a program initiated in 2012 by the Department of Energy Office of Nuclear Energy (DOE-NE), a review was completed to gain insights from prior TMI-2 sensor survivability and data qualification efforts. This new effort focussed upon a set of sensorsmore » that provided critical data to TMI-2 operators for assessing the condition of the plant and the effects of mitigating actions taken by these operators. In addition, the effort considered sensors providing data required for subsequent accident simulations. Over 100 references related to instrumentation performance and post-accident evaluations of TMI-2 sensors and measurements were reviewed. Insights gained from this review are summarized within this report. For each sensor, a description is provided with the measured data and conclusions related to the sensor’s survivability, and the basis for conclusions about its survivability. As noted within this document, several techniques were invoked in the TMI-2 post-accident evaluation program to assess sensor status, including comparisons with data from other sensors, analytical calculations, laboratory testing, and comparisons with sensors subjected to similar conditions in large-scale integral tests and with sensors that were similar in design but more easily removed from the TMI-2 plant for evaluations. Conclusions from this review provide important insights related to sensor survivability and enhancement options for improving sensor performance. In addition, this document provides recommendations related to the sensor survivability and data evaluation process that could be implemented in upcoming Fukushima Daiichi recovery efforts.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dominick, F.; Lockwood, R.A.
1986-07-01
The US Army Aviation Engineering Flight Activity conducted an evaluation of Flight Management Calculator for the UH-1H. The calculator was a Hewlett-Packard HP-41CV. The performance calculator was evaluated for flight planning and in-flight use during 14 mission flights simulating operational conditions. The calculator was much easier to use in-flight than the operator's manual data. The calculator program needs improvement in the areas of pre-flight planning and execution speed. The mission flights demonstrated a 19% fuel saving using optimum over normal flight profiles in warm temperatures (15/sup 0/C above standard). Savings would be greater at colder temperatures because of increasing compressibilitymore » effects. Acceptable accuracy for individual aircraft under operational conditions may require a regressive analog model in which individual aircraft data are used to update the program. The performance data base for the UH-1H was expanded with level flight and hover data to thrust coefficients and Mach numbers to the practical limits of aircraft operation.« less
Vanlandewijck, Yves C; Verellen, Joeri; Tweedy, Sean
2011-07-01
In most Paralympic wheelchair sports, active trunk range of movement is assessed by observing shoulder girdle excursion during active trunk movements and is a key determinant of an athlete's class. However, to date research evaluating the impact of reduced trunk range of movement on wheelchair sports performance has not been conducted. In the present study, 15 non-disabled male participants performed two 20-s sprints on a wheelchair ergometer in each of three seating positions. Positions were typical of those used to enhance sitting stability in wheelchair sport and each impacted available trunk range of movement differently: condition-90 (seated with thighs horizontal; unrestricted range of movement) condition-45 (seated with thighs in 45°), and condition-0 (seated with hips maximally flexed; minimum range of movement). In condition-90, the trunk only actively contributed to the first push; for the remainder of the sprint, the trunk was held almost isometrically at 48.2° to the horizontal (range 42.1-56.4°). Similar patterns were observed for both condition-45 and condition-0. Compared with condition-90, participants in condition-0 had reduced capacity to accelerate of statistical (P < 0.05) and practical significance. These findings are an important initial step towards evidence-based decision making in classification. Future research should evaluate the individual and collective impact of other factors that affect the trunk's contribution to wheelchair sports performance, including strapping, seating position, and impairments of trunk muscle power and coordination.
Pilot GPS LORAN Receiver Programming Performance A Laboratory Evaluation
DOT National Transportation Integrated Search
1994-02-01
This study was designed to explore GPS/LORAN receiver programming performance under : simulated flight conditions. The programming task consisted of entering, editing, and : verifying a four-waypoint flight plan. The task demands were manipulated by ...
Performance degradation of helicopter rotor in forward flight due to ice
NASA Technical Reports Server (NTRS)
Korkan, K. D.; Dadone, L.; Shaw, R. J.
1985-01-01
This study addresses the analytical assessment of the degradation in the forward flight performance of the front rotor Boeing Vertol CH47D helicopter in a rime ice natural icing encounter. The front rotor disk was divided into 24 15-deg sections and the local Mach number and angle of attack were evaluated as a function of azimuthal and radial location for a specified flight condition. Profile drag increments were then calculated as a function of azimuthal and radial position for different times of exposure to icing, and the rotor performance was re-evaluated including these drag increments. The results of the analytical prediction method, such as horsepower required to maintain a specific flight condition, as a function of icing time have been generated. The method to illustrate the value of such an approach in assessing performance changes experienced by a helicopter rotor as a result of rime ice accretion is described.
ERIC Educational Resources Information Center
Lewis, M. Samantha; Gallun, Frederick J.; Gordon, Jane; Lilly, David J.; Crandell, Carl
2010-01-01
While the concurrent use of the hearing aid (HA) microphone with frequency modulation (FM) technology can decrease speech-recognition performance, the FM+HA condition is still an important setting for users of both HA and FM technology. The primary goal of this investigation was to evaluate the effect of attenuating HA gain in the FM+HA listening…
Comparison Evaluations of VRF and RTU Systems Performance on Flexible Research Platform
Lee, Je-hyeon; Im, Piljae; Munk, Jeffrey D.; ...
2018-04-05
The energy performance of a variable refrigerant flow (VRF) system was evaluated using an occupancy-emulated research building in the southeastern region of the United States. Full- and part-load performance of the VRF system in heating and cooling seasons was compared with a conventional rooftop unit (RTU) variable-air-volume system with electric resistance heating. During both the heating and cooling seasons, full- and part-load conditions (i.e., 100%, 75%, and 50% thermal loads) were maintained alternately for 2 to 3 days each, and the energy use, thermal conditions, and coefficient of performance (COP) for the RTU and VRF system were measured. During themore » cooling season, the VRF system had an average COP of 4.2, 3.9, and 3.7 compared with 3.1, 3.0, and 2.5 for the RTU system under 100%, 75%, and 50% load conditions and resulted in estimated energy savings of 30%, 37%, and 47%, respectively. Finally, during the heating season, the VRF system had an average COP ranging from 1.2 to 2.0, substantially higher than the COPs of the RTU system, and resulted in estimated energy savings of 51%, 47%, and 27% under the three load conditions, respectively.« less
Comparison Evaluations of VRF and RTU Systems Performance on Flexible Research Platform
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Je-hyeon; Im, Piljae; Munk, Jeffrey D.
The energy performance of a variable refrigerant flow (VRF) system was evaluated using an occupancy-emulated research building in the southeastern region of the United States. Full- and part-load performance of the VRF system in heating and cooling seasons was compared with a conventional rooftop unit (RTU) variable-air-volume system with electric resistance heating. During both the heating and cooling seasons, full- and part-load conditions (i.e., 100%, 75%, and 50% thermal loads) were maintained alternately for 2 to 3 days each, and the energy use, thermal conditions, and coefficient of performance (COP) for the RTU and VRF system were measured. During themore » cooling season, the VRF system had an average COP of 4.2, 3.9, and 3.7 compared with 3.1, 3.0, and 2.5 for the RTU system under 100%, 75%, and 50% load conditions and resulted in estimated energy savings of 30%, 37%, and 47%, respectively. Finally, during the heating season, the VRF system had an average COP ranging from 1.2 to 2.0, substantially higher than the COPs of the RTU system, and resulted in estimated energy savings of 51%, 47%, and 27% under the three load conditions, respectively.« less
Li, Ke; Zhang, Qiuju; Wang, Kun; Chen, Peng; Wang, Huaqing
2016-01-01
A new fault diagnosis method for rotating machinery based on adaptive statistic test filter (ASTF) and Diagnostic Bayesian Network (DBN) is presented in this paper. ASTF is proposed to obtain weak fault features under background noise, ASTF is based on statistic hypothesis testing in the frequency domain to evaluate similarity between reference signal (noise signal) and original signal, and remove the component of high similarity. The optimal level of significance α is obtained using particle swarm optimization (PSO). To evaluate the performance of the ASTF, evaluation factor Ipq is also defined. In addition, a simulation experiment is designed to verify the effectiveness and robustness of ASTF. A sensitive evaluation method using principal component analysis (PCA) is proposed to evaluate the sensitiveness of symptom parameters (SPs) for condition diagnosis. By this way, the good SPs that have high sensitiveness for condition diagnosis can be selected. A three-layer DBN is developed to identify condition of rotation machinery based on the Bayesian Belief Network (BBN) theory. Condition diagnosis experiment for rolling element bearings demonstrates the effectiveness of the proposed method. PMID:26761006
Li, Ke; Zhang, Qiuju; Wang, Kun; Chen, Peng; Wang, Huaqing
2016-01-08
A new fault diagnosis method for rotating machinery based on adaptive statistic test filter (ASTF) and Diagnostic Bayesian Network (DBN) is presented in this paper. ASTF is proposed to obtain weak fault features under background noise, ASTF is based on statistic hypothesis testing in the frequency domain to evaluate similarity between reference signal (noise signal) and original signal, and remove the component of high similarity. The optimal level of significance α is obtained using particle swarm optimization (PSO). To evaluate the performance of the ASTF, evaluation factor Ipq is also defined. In addition, a simulation experiment is designed to verify the effectiveness and robustness of ASTF. A sensitive evaluation method using principal component analysis (PCA) is proposed to evaluate the sensitiveness of symptom parameters (SPs) for condition diagnosis. By this way, the good SPs that have high sensitiveness for condition diagnosis can be selected. A three-layer DBN is developed to identify condition of rotation machinery based on the Bayesian Belief Network (BBN) theory. Condition diagnosis experiment for rolling element bearings demonstrates the effectiveness of the proposed method.
Jacobsen, Thomas; Höfel, Lea
2003-12-01
Descriptive symmetry and evaluative aesthetic judgment processes were compared using identical stimuli in both judgment tasks. Electrophysiological activity was recorded while participants judged novel formal graphic patterns in a trial-by-trial cuing setting using binary responses (symmetric, not symmetric; beautiful, not beautiful). Judgment analyses of a Phase 1 test and main experiment performance resulted in individual models, as well as group models, of the participants' judgment systems. Symmetry showed a strong positive correlation with beautiful judgments and was the most important cue. Descriptive judgments were performed faster than evaluative judgments. The ERPs revealed a phasic, early frontal negativity for the not-beautiful judgments. A sustained posterior negativity was observed in the symmetric condition. All conditions showed late positive potentials (LPPs). Evaluative judgment LPPs revealed a more pronounced right lateralization. It is argued that the present aesthetic judgments engage a two-stage process consisting of early, anterior frontomedian impression formation after 300 msec and right-hemisphere evaluative categorization around 600 msec after onset of the graphic patterns.
Stability of prebiotic, laminaran oligosaccharide under food processing conditions
NASA Astrophysics Data System (ADS)
Chamidah, A.
2018-04-01
Prebiotic stability tests on laminaran oligosaccharide under food processing conditions were urgently performed to determine the ability of prebiotics deal with processing. Laminaran, oligosaccharide is produced from enzymatic hydrolysis. To further apply this prebiotic, it is necessary to test its performance on food processing. Single prebiotic or in combination with probiotic can improve human digestive health. The effectiveness evaluation of prebiotic should be taken into account in regards its chemical and functional stabilities. This study aims to investigate the stability of laminaran, oligosaccharide under food processing condition.
A study on task difficulty and acceleration stress
NASA Technical Reports Server (NTRS)
Repperger, D. W.; Rogers, D. B.
1981-01-01
The results of two experiments which relate to task difficulty and the effects of environmental stress on tracking performance are discussed and compared to subjective evaluations. The first experiment involved five different sum of sine tracking tasks which humans tracked both in a static condition and under a 5 Gz acceleration stress condition. The second experiment involved similar environmental stress conditions but in this case the tasks were constructed from deterministic functions with specially designed velocity and acceleration profiles. Phase Plane performance analysis was conducted to study potential measures of workload or tracking difficulty.
Nondestructive evaluation of composite materials - A design philosophy
NASA Technical Reports Server (NTRS)
Duke, J. C., Jr.; Henneke, E. G., II; Stinchcomb, W. W.; Reifsnider, K. L.
1984-01-01
Efficient and reliable structural design utilizing fiber reinforced composite materials may only be accomplished if the materials used may be nondestructively evaluated. There are two major reasons for this requirement: (1) composite materials are formed at the time the structure is fabricated and (2) at practical strain levels damage, changes in the condition of the material, that influence the structure's mechanical performance is present. The fundamental basis of such a nondestructive evaluation capability is presented. A discussion of means of assessing nondestructively the material condition as well as a damage mechanics theory that interprets the material condition in terms of its influence on the mechanical response, stiffness, strength and life is provided.
Yalcin, Arzu Didem; Basaran, Saime; Bisgin, Atil; Polat, Hasan Hüseyin; Gorczynski, Reginald M
2013-02-11
We evaluated the profiles of allergic rhino-conjunctivitis and asthma patients annually in Antalya, a Mediterranean coastal city in Turkey. We evaluated patients' allergic clinical status, and recorded the climate and pollens in the city center air, investigating any correlation between pollination, climatic conditions and allergic disorders. The meteorological conditions and the pollen count/cm2 during every month of the year and the concordance of this with the patient's clinical status were evaluated. SPT positivity for plantago lanceolata, aspergillus fumigatus and d. pteronyssinus was significant in patients younger than 40 years old. Pollination levels are consistent from March 2010 to February 2011. In Antalya, high levels occur mostly from April to June, thus we performed skin prick tests mostly in May/June (~30%). During these months meteorological conditions of the city were windy with low humidity, without rain, and lukewarm temperatures, all of which contribute to high-risk conditions for seasonal allergies. The major allergen between April and June was derived from Graminea; between February and March was Cupressus spp; and between March and June was Pinus spp. These results suggest that the pollination is correlated with allergic conditions and thus SPT might be best performed according to the pollen count.
Jamaludin, Farah Adilah; Ab-Kadir, Mohd Zainal Abidin; Izadi, Mahdi; Azis, Norhafiz; Jasni, Jasronita; Abd-Rahman, Muhammad Syahmi
2017-01-01
Located near the equator, Malaysia is a country with one of the highest lightning densities in the world. Lightning contributes to 70% of the power outages in Malaysia and affects power equipment, automated network systems, causes data losses and monetary losses in the nation. Therefore, consideration of insulator evaluation under lightning impulses can be crucial to evaluate and attempt to overcome this issue. This paper presents a new approach to increase the electrical performance of polymer insulators using a Room Temperature Vulcanisation (RTV) coating. The evaluation involves three different settings of polymer insulator, namely uncoated, RTV type 1, and RTV type 2 upper surface coatings. All the insulators were tested under three different conditions as dry, clean wet and salty under different impulse polarities using the even-rising test method. The voltage breakdown for each test was recorded. From the experiment, it was found that the effectiveness of the RTV coating application became apparent when tested under salty or polluted conditions. It increased the voltage withstand capabilities of the polymer insulator up to 50% from the basic uncoated insulator. Under dry and clean conditions, the RTV coating provided just a slight increase of the breakdown voltage. The increase in voltage breakdown capability decreased the probability of surface discharge and dry band arcing that could cause degradation of the polymeric material housing. The RTV type 1 coating was found to be more effective when performing under a lightning impulse. The findings might help the utility companies improve the performance of their insulators in order to increase power system reliability.
Jamaludin, Farah Adilah; Ab-Kadir, Mohd Zainal Abidin; Izadi, Mahdi; Azis, Norhafiz; Jasni, Jasronita; Abd-Rahman, Muhammad Syahmi
2017-01-01
Located near the equator, Malaysia is a country with one of the highest lightning densities in the world. Lightning contributes to 70% of the power outages in Malaysia and affects power equipment, automated network systems, causes data losses and monetary losses in the nation. Therefore, consideration of insulator evaluation under lightning impulses can be crucial to evaluate and attempt to overcome this issue. This paper presents a new approach to increase the electrical performance of polymer insulators using a Room Temperature Vulcanisation (RTV) coating. The evaluation involves three different settings of polymer insulator, namely uncoated, RTV type 1, and RTV type 2 upper surface coatings. All the insulators were tested under three different conditions as dry, clean wet and salty under different impulse polarities using the even-rising test method. The voltage breakdown for each test was recorded. From the experiment, it was found that the effectiveness of the RTV coating application became apparent when tested under salty or polluted conditions. It increased the voltage withstand capabilities of the polymer insulator up to 50% from the basic uncoated insulator. Under dry and clean conditions, the RTV coating provided just a slight increase of the breakdown voltage. The increase in voltage breakdown capability decreased the probability of surface discharge and dry band arcing that could cause degradation of the polymeric material housing. The RTV type 1 coating was found to be more effective when performing under a lightning impulse. The findings might help the utility companies improve the performance of their insulators in order to increase power system reliability. PMID:29136025
NASA Technical Reports Server (NTRS)
Shelton, Kevin J.; Kramer, Lynda J.; Ellis,Kyle K.; Rehfeld, Sherri A.
2012-01-01
The Synthetic and Enhanced Vision Systems for NextGen (SEVS) simulation and flight tests are jointly sponsored by NASA's Aviation Safety Program, Vehicle Systems Safety Technology project and the Federal Aviation Administration (FAA). The flight tests were conducted by a team of Honeywell, Gulfstream Aerospace Corporation and NASA personnel with the goal of obtaining pilot-in-the-loop test data for flight validation, verification, and demonstration of selected SEVS operational and system-level performance capabilities. Nine test flights (38 flight hours) were conducted over the summer and fall of 2011. The evaluations were flown in Gulfstream.s G450 flight test aircraft outfitted with the SEVS technology under very low visibility instrument meteorological conditions. Evaluation pilots flew 108 approaches in low visibility weather conditions (600 ft to 2400 ft visibility) into various airports from Louisiana to Maine. In-situ flight performance and subjective workload and acceptability data were collected in collaboration with ground simulation studies at LaRC.s Research Flight Deck simulator.
Barrio, Javier; Errando, Carlos L; García-Ramón, Jaime; Sellés, Rafael; San Miguel, Guillermo; Gallego, Juan
2017-11-01
To evaluate the influence of neuromuscular blockade (NMB) on surgical conditions during low-pressure pneumoperitoneum (8mmHg) laparoscopic cholecystectomy (LC), while comparing moderate and deep NMB. Secondary objective was to evaluate if surgical conditions during low-pressure pneumoperitoneum LC performed with deep NMB could be comparable to those provided during standard-pressure pneumoperitoneum (12mmHg) LC. Prospective, randomized, blinded clinical trial. Operating room. Ninety ASA 1-2 patients scheduled for elective LC. Patients were allocated into 3 groups: Group 1: low-pressure pneumoperitoneum with moderate-NMB (1-3 TOF), Group 2: low-pressure pneumoperitoneum with deep-NMB (1-5 PTC) and Group 3: standard pneumoperitoneum (12mmHg). Rocuronium was used to induce NMB and acceleromiography was used for NMB monitoring (TOF-Watch-SX). Three experienced surgeons evaluated surgical conditions using a four-step scale at three time-points: surgical field exposure, dissection of the gallbladder and extraction/closure. Low-pressure pneumoperitoneum (Group 1 vs. 2): good conditions: 96.7 vs. 96.7%, 90 vs. 80% and 89.6 vs. 92.3%, respectively for the time-points, p>0.05. No differences in optimal surgical conditions were observed between the groups. Surgery completion at 8mmHg pneumoperitoneum: 96.7 vs. 86.7%, p=0.353. Standard-pressure pneumoperitoneum vs. low-pressure pneumoperitoneum with deep NMB (Group 3 vs. 2): good conditions: 100% in Group 3 for the three time-points (p=0.024 vs. Group 2 at dissection of the gallbladder). Significantly greater percentage of optimal conditions during standard-pressure pneumoperitoneum LC at the three time points of evaluation. The depth of NMB was found not to be decisive neither in the improvement of surgical conditions nor in the completion of low-pressure pneumoperitoneum LC performed by experienced surgeons. Surgical conditions were considered better with a standard-pressure pneumoperitoneum, regardless of the depth of NMB, than during low-pressure pneumoperitoneum with deep NMB. Copyright © 2017 Elsevier Inc. All rights reserved.
Parmar, Suresh; Khodasevych, Iryna; Troynikov, Olga
2017-08-21
The recent use of graduated compression therapy for treatment of chronic venous disorders such as leg ulcers and oedema has led to considerable research interest in flexible and low-cost force sensors. Properly applied low pressure during compression therapy can substantially improve the treatment of chronic venous disorders. However, achievement of the recommended low pressure levels and its accurate determination in real-life conditions is still a challenge. Several thin and flexible force sensors, which can also function as pressure sensors, are commercially available, but their real-life sensing performance has not been evaluated. Moreover, no researchers have reported information on sensor performance during static and dynamic loading within the realistic test conditions required for compression therapy. This research investigated the sensing performance of five low-cost commercial pressure sensors on a human-leg-like test apparatus and presents quantitative results on the accuracy and drift behaviour of these sensors in both static and dynamic conditions required for compression therapy. Extensive experimental work on this new human-leg-like test setup demonstrated its utility for evaluating the sensors. Results showed variation in static and dynamic sensing performance, including accuracy and drift characteristics. Only one commercially available pressure sensor was found to reliably deliver accuracy of 95% and above for all three test pressure points of 30, 50 and 70 mmHg.
Parmar, Suresh; Khodasevych, Iryna; Troynikov, Olga
2017-01-01
The recent use of graduated compression therapy for treatment of chronic venous disorders such as leg ulcers and oedema has led to considerable research interest in flexible and low-cost force sensors. Properly applied low pressure during compression therapy can substantially improve the treatment of chronic venous disorders. However, achievement of the recommended low pressure levels and its accurate determination in real-life conditions is still a challenge. Several thin and flexible force sensors, which can also function as pressure sensors, are commercially available, but their real-life sensing performance has not been evaluated. Moreover, no researchers have reported information on sensor performance during static and dynamic loading within the realistic test conditions required for compression therapy. This research investigated the sensing performance of five low-cost commercial pressure sensors on a human-leg-like test apparatus and presents quantitative results on the accuracy and drift behaviour of these sensors in both static and dynamic conditions required for compression therapy. Extensive experimental work on this new human-leg-like test setup demonstrated its utility for evaluating the sensors. Results showed variation in static and dynamic sensing performance, including accuracy and drift characteristics. Only one commercially available pressure sensor was found to reliably deliver accuracy of 95% and above for all three test pressure points of 30, 50 and 70 mmHg. PMID:28825672
42 CFR 403.740 - Condition of participation: Staffing.
Code of Federal Regulations, 2010 CFR
2010-10-01
...: Education, training, and performance evaluation. (1) The RNHCI must ensure that staff (including contractors and other individuals working under arrangement) have the necessary education and training concerning... to, training related to the individual job description, performance expectations, applicable...
NASA Astrophysics Data System (ADS)
Yalcin, Enver
2017-05-01
The environmental parameters such as temperature and air pressure which are changing depending on altitudes are effective on thrust and fuel consumption of aircraft engines. In flights with long routes, thrust management function in airplane information system has a structure that ensures altitude and performance management. This study focused on thrust changes throughout all flight were examined by taking into consideration their energy and exergy performances for fuel consumption of an aircraft engine used in flight with long route were taken as reference. The energetic and exergetic performance evaluations were made under the various altitude conditions. The thrust changes for different altitude conditions were obtained to be at 86.53 % in descending direction and at 142.58 % in ascending direction while the energy and exergy efficiency changes for the referenced engine were found to be at 80.77 % and 84.45 %, respectively. The results revealed here can be helpful to manage thrust and reduce fuel consumption, but engine performance will be in accordance with operation requirements.
da Silva, M C L; Nascimento, A M; da Silva, V L; Pons, M N; da Motta, M
2009-01-01
An evaluation of the efficiency of bacterial biomass augmentation was performed at lab-scale for the pollution treatment of the Derby-Tacaruna canal. The canal is located at the central area of Great Recife, alongside an important urban corridor. The characterization of the canal water in different tidal conditions showed that the actual pollution is organic and inorganic (heavy metals). Degradation experiments of water from the canal and rain-off system polluted by synthetic wastewater were performed, using activated sludge and an industrial bioadditive. Continuous reactors under two different conditions were evaluated: with diffuse aeration and without aeration. The channel reactor was operated under steady state conditions at a flow rate of 2.5 L h(-1) and with an average residence time of 22 h without aeration and 17 h with aeration. The organic matter removal was in the range of 60% for the system inoculated with the bioadditive and 85% with activated sludge. It was concluded that the water of the Derby-Tacaruna canal may be treated by activated sludge without being affected by its salt content, while the bioaugmentation technique was not satisfactory due to inhibition by inorganics.
Optimization Of PVDF-TrFE Processing Conditions For The Fabrication Of Organic MEMS Resonators
Ducrot, Pierre-Henri; Dufour, Isabelle; Ayela, Cédric
2016-01-01
This paper reports a systematic optimization of processing conditions of PVDF-TrFE piezoelectric thin films, used as integrated transducers in organic MEMS resonators. Indeed, despite data on electromechanical properties of PVDF found in the literature, optimized processing conditions that lead to these properties remain only partially described. In this work, a rigorous optimization of parameters enabling state-of-the-art piezoelectric properties of PVDF-TrFE thin films has been performed via the evaluation of the actuation performance of MEMS resonators. Conditions such as annealing duration, poling field and poling duration have been optimized and repeatability of the process has been demonstrated. PMID:26792224
Optimization Of PVDF-TrFE Processing Conditions For The Fabrication Of Organic MEMS Resonators.
Ducrot, Pierre-Henri; Dufour, Isabelle; Ayela, Cédric
2016-01-21
This paper reports a systematic optimization of processing conditions of PVDF-TrFE piezoelectric thin films, used as integrated transducers in organic MEMS resonators. Indeed, despite data on electromechanical properties of PVDF found in the literature, optimized processing conditions that lead to these properties remain only partially described. In this work, a rigorous optimization of parameters enabling state-of-the-art piezoelectric properties of PVDF-TrFE thin films has been performed via the evaluation of the actuation performance of MEMS resonators. Conditions such as annealing duration, poling field and poling duration have been optimized and repeatability of the process has been demonstrated.
Evaluation of Gear Condition Indicator Performance on Rotorcraft Fleet
NASA Technical Reports Server (NTRS)
Antolick, Lance J.; Branning, Jeremy S.; Wade, Daniel R.; Dempsey, Paula J.
2010-01-01
The U.S. Army is currently expanding its fleet of Health Usage Monitoring Systems (HUMS) equipped aircraft at significant rates, to now include over 1,000 rotorcraft. Two different on-board HUMS, the Honeywell Modern Signal Processing Unit (MSPU) and the Goodrich Integrated Vehicle Health Management System (IVHMS), are collecting vibration health data on aircraft that include the Apache, Blackhawk, Chinook, and Kiowa Warrior. The objective of this paper is to recommend the most effective gear condition indicators for fleet use based on both a theoretical foundation and field data. Gear diagnostics with better performance will be recommended based on both a theoretical foundation and results of in-fleet use. In order to evaluate the gear condition indicator performance on rotorcraft fleets, results of more than five years of health monitoring for gear faults in the entire HUMS equipped Army helicopter fleet will be presented. More than ten examples of gear faults indicated by the gear CI have been compiled and each reviewed for accuracy. False alarms indications will also be discussed. Performance data from test rigs and seeded fault tests will also be presented. The results of the fleet analysis will be discussed, and a performance metric assigned to each of the competing algorithms. Gear fault diagnostic algorithms that are compliant with ADS-79A will be recommended for future use and development. The performance of gear algorithms used in the commercial units and the effectiveness of the gear CI as a fault identifier will be assessed using the criteria outlined in the standards in ADS-79A-HDBK, an Army handbook that outlines the conversion from Reliability Centered Maintenance to the On-Condition status of Condition Based Maintenance.
Evaluation of Passive Vents in New Construction Multifamily Buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maxwell, Sean; Berger, David; Zuluaga, Marc
Exhaust ventilation and corresponding outdoor air strategies are being implemented in high-performance new construction multifamily buildings to meet program or code requirements for improved indoor air quality, but a lack of clear design guidance is resulting in poor performance of these systems despite the best intentions of the programs or standards. CARB's 2014 'Evaluation of Ventilation Strategies in New Construction Multifamily Buildings' consistently demonstrated that commonly used outdoor air strategies are not performing as expected. Of the four strategies evaluated in 2014, the exhaust ventilation system that relied on outdoor air from a pressurized corridor was ruled out as amore » potential best practice due to its conflict with meeting requirements within most fire codes. Outdoor air that is ducted directly to the apartments was a strategy determined to have the highest likelihood of success, but with higher first costs and operating costs. Outdoor air through space conditioning systems was also determined to have good performance potential, with proper design and execution. The fourth strategy, passive systems, was identified as the least expensive option for providing outdoor air directly to apartments, with respect to both first costs and operating costs. However, little is known about how they actually perform in real-world conditions or how to implement them effectively. Based on the lack of data available on the performance of these low-cost systems and their frequent use in the high-performance building programs that require a provision for outdoor air, this research project sought to further evaluate the performance of passive vents.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Exhaust ventilation and corresponding outdoor air strategies are being implemented in high-performance new construction multifamily buildings to meet program or code requirements for improved indoor air quality, but a lack of clear design guidance is resulting in poor performance of these systems despite the best intentions of the programs or standards. CARB's 2014 'Evaluation of Ventilation Strategies in New Construction Multifamily Buildings' consistently demonstrated that commonly used outdoor air strategies are not performing as expected. Of the four strategies evaluated in 2014, the exhaust ventilation system that relied on outdoor air from a pressurized corridor was ruled out as amore » potential best practice due to its conflict with meeting requirements within most fire codes. Outdoor air that is ducted directly to the apartments was a strategy determined to have the highest likelihood of success, but with higher first costs and operating costs. Outdoor air through space conditioning systems was also determined to have good performance potential, with proper design and execution. The fourth strategy, passive systems, was identified as the least expensive option for providing outdoor air directly to apartments, with respect to both first costs and operating costs. However, little is known about how they actually perform in real-world conditions or how to implement them effectively. Based on the lack of data available on the performance of these low-cost systems and their frequent use in the high-performance building programs that require a provision for outdoor air, this research project sought to further evaluate the performance of passive vents.« less
Studying Light Color using White LED Lighting
NASA Astrophysics Data System (ADS)
Yamagishi, Misako; Yamaba, Kazuo; Nagata, Manori; Kubo, Chiho; Nokura, Kunihiro
Recently, white Light Emitting Diodes (LEDs) are receiving attention worldwide as new lighting devices. This study examined effects of a lighting application on performance using white LEDs. The light color—the correlated color temperature (CCT) —was assessed. It affected to psychological states and physiological conditions. Three CCT conditions were respectively set for the experiment: 2500 K, 5000 K, and 8200 K. In all, 20 younger subjects (20-30 years old), 15 middle-aged to elderly subjects (45-60 years old) and 12 elderly subjects (over 65 years-old) participated. They were presented a Numerical Verification (NV) task for performance measurement. The psychological states on performance were evaluated using the lighting assessment questionnaire. The physiological conditions were recorded using an electrocardiograph. Results show that the effects of CCT differ among age groups. Especially, the performance of younger subjects might differ from CCT conditions; elderly subjects are affected by CCT condition because of their visual acuity or response to contrast of objects.
NASA Technical Reports Server (NTRS)
Simon, F. F.
1975-01-01
A performance evaluation was made of two, black nickel coated, flat plate solar collectors. Collector performance was determined under a simulated sun for a wide range of inlet temperatures, including the temperature required for solar powered absorption air conditioning. For a basis of comparison a performance test was made on a traditional, two glass, nonselective, black paint coated, flat plate collector. Performance curves and performance parameters are presented to point out the importance of the design variables which determine an efficient collector. A black nickel coated collector was found to be a good performer at the conditions expected for solar powered absorption air conditioning. This collector attained a thermal efficiency of 50 percent at an inlet temperature of 366 K (200 F) and an incident flux of 946 watts/sq m (300 Btu/hr-sq ft).
NASA Technical Reports Server (NTRS)
Takallu, M. A.; Wong, D. T.; Uenking, M. D.
2002-01-01
An experimental investigation was conducted to study the effectiveness of modern flight displays in general aviation cockpits for mitigating Low Visibility Loss of Control and the Controlled Flight Into Terrain accidents. A total of 18 General Aviation (GA) pilots with private pilot, single engine land rating, with no additional instrument training beyond private pilot license requirements, were recruited to evaluate three different display concepts in a fixed-based flight simulator at the NASA Langley Research Center's General Aviation Work Station. Evaluation pilots were asked to continue flight from Visual Meteorological Conditions (VMC) into Instrument Meteorological Conditions (IMC) while performing a series of 4 basic precision maneuvers. During the experiment, relevant pilot/vehicle performance variables, pilot control inputs and physiological data were recorded. Human factors questionnaires and interviews were administered after each scenario. Qualitative and quantitative data have been analyzed and the results are presented here. Pilot performance deviations from the established target values (errors) were computed and compared with the FAA Practical Test Standards. Results of the quantitative data indicate that evaluation pilots committed substantially fewer errors when using the Synthetic Vision Systems (SVS) displays than when they were using conventional instruments. Results of the qualitative data indicate that evaluation pilots perceived themselves to have a much higher level of situation awareness while using the SVS display concept.
Parametric performance of a turbojet engine combustor using jet A and A diesel fuel
NASA Technical Reports Server (NTRS)
Butze, H. F.; Humenik, F. M.
1979-01-01
The performance of a single-can JT8D combustor was evaluated with Jet A and a high-aromatic diesel fuel over a parametric range of combustor-inlet conditions. Performance parameters investigated were combustion efficiency, emissions of CO, unburned hydrocarbons, and NOx, as well as liner temperatures and smoke. At all conditions the use of diesel fuel instead of Jet A resulted in increases in smoke numbers and liner temperatures; gaseous emissions, on the other hand, did not differ significantly between the two fuels.
Commercial Absorption Heat Pump Water Heater: Beta Prototype Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geoghegan, Patrick; Ally, Moonis; Sharma, Vishaldeep
2016-10-14
The Beta version of the Commercial Absorption Heat Pump (CAHP) water heater was evaluated in the environmental chambers at Oak Ridge National Laboratory. Ambient air conditions ranged from 17 to 75 oF and inlet water temperatures ranged from 100 to 120oF in order to capture trends in performance. The unit was operated under full fire (100%) and partial fire (55%). The unit was found to perform at 90% of the project goal at the design conditions of 47oF ambient and 100oF water temperatures. The trends across the full range of environmental conditions were as expected for ambient air temperatures abovemore » 32oF. Below this temperature and for the full fire condition, frost accumulated on the evaporator coil. In future work a defrost strategy will be enabled, the unit will be thoroughly cleaned of an oil contamination and the rectifier will be reconfigured in order to meet the design goals and have a field test unit ready in early 2017.« less
Employee Performance in the Context of the Problems of Measurement and Evaluation in Practice
NASA Astrophysics Data System (ADS)
Szabó, Peter; Mĺkva, Miroslava; Vaňová, Jaromíra; Marková, Petra
2017-09-01
Employee performance is a condition and an assumption for the performance and success of a company on the market. In order to ensure competitive ability, the quality of human resources, their management, and related measurement and performance assessment are at the forefront of company interest. Employee assessment affects the performance, development and motivation of people and also provides the necessary information about the employees. It allows the organization to monitor employee performance and compare their work with other collaborators. Many companies have the problem of setting up evaluation system so that it carried itself elements of responsibility and objectivity. The result of conceptual work in this area is the ultimate use of tools whose deployment, if possible, motivates employees to perform better. The aim of the paper is to refer to problems that arise in companies in evaluating the performance of employees.
A computer program for condensing heat exchanger performance in the presence of noncondensable gases
NASA Technical Reports Server (NTRS)
Yendler, Boris
1994-01-01
A computer model has been developed which evaluates the performance of a heat exchanger. This model is general enough to be used to evaluate many heat exchanger geometries and a number of different operating conditions. The film approach is used to describe condensation in the presence of noncondensables. The model is also easily expanded to include other effects like fog formation or suction.
Knowledge-Acquisition Tool For Expert System
NASA Technical Reports Server (NTRS)
Disbrow, James D.; Duke, Eugene L.; Regenie, Victoria A.
1988-01-01
Digital flight-control systems monitored by computer program that evaluates and recommends. Flight-systems engineers for advanced, high-performance aircraft use knowlege-acquisition tool for expert-system flight-status monitor suppling interpretative data. Interpretative function especially important in time-critical, high-stress situations because it facilitates problem identification and corrective strategy. Conditions evaluated and recommendations made by ground-based engineers having essential knowledge for analysis and monitoring of performances of advanced aircraft systems.
Monitoring loading and environmental effects on bridge performance : research brief.
DOT National Transportation Integrated Search
2011-03-01
A pilot project was initiated to assess the performance of the HPS bridge members as well as to evaluate : the response of the structure to actual traffic and environmental loads under in-service conditions : through monitoring of strain, temperature...
Evaluation plan for space station network interface units
NASA Technical Reports Server (NTRS)
Weaver, Alfred C.
1990-01-01
Outlined here is a procedure for evaluating network interface units (NIUs) produced for the Space Station program. The procedures should be equally applicable to the data management system (DMS) testbed NIUs produced by Honeywell and IBM. The evaluation procedures are divided into four areas. Performance measurement tools are hardware and software that must be developed in order to evaluate NIU performance. Performance tests are a series of tests, each of which documents some specific characteristic of NIU and/or network performance. In general, these performance tests quantify the speed, capacity, latency, and reliability of message transmission under a wide variety of conditions. Functionality tests are a series of tests and code inspections that demonstrate the functionality of the particular subset of ISO protocols which have been implemented in a given NIU. Conformance tests are a series of tests which would expose whether or not selected features within the ISO protocols are present and interoperable.
Performability evaluation of the SIFT computer
NASA Technical Reports Server (NTRS)
Meyer, J. F.; Furchtgott, D. G.; Wu, L. T.
1979-01-01
Performability modeling and evaluation techniques are applied to the SIFT computer as it might operate in the computational evironment of an air transport mission. User-visible performance of the total system (SIFT plus its environment) is modeled as a random variable taking values in a set of levels of accomplishment. These levels are defined in terms of four attributes of total system behavior: safety, no change in mission profile, no operational penalties, and no economic process whose states describe the internal structure of SIFT as well as relavant conditions of the environment. Base model state trajectories are related to accomplishment levels via a capability function which is formulated in terms of a 3-level model hierarchy. Performability evaluation algorithms are then applied to determine the performability of the total system for various choices of computer and environment parameter values. Numerical results of those evaluations are presented and, in conclusion, some implications of this effort are discussed.
How to perform a critically appraised topic: part 2, appraise, evaluate, generate, and recommend.
Kelly, Aine Marie; Cronin, Paul
2011-11-01
This article continues the discussion of a critically appraised topic started in Part 1. A critically appraised topic is a practical tool for learning and applying critical appraisal skills. This article outlines steps 4-7 involved in performing a critically appraised topic for studies of diagnostic tests: Appraise, Appraise the literature; Evaluate, evaluate the strength of the evidence from the literature; Generate, generate graphs of conditional probability; and Recommend, draw conclusions and make recommendations. For steps 4-7 of performing a critically appraised topic, the main study results are summarized and translated into clinically useful measures of accuracy, efficacy, or risk.
Predicted and tested performance of durable TPS
NASA Technical Reports Server (NTRS)
Shideler, John L.
1992-01-01
The development of thermal protection systems (TPS) for aerospace vehicles involves combining material selection, concept design, and verification tests to evaluate the effectiveness of the system. The present paper reviews verification tests of two metallic and one carbon-carbon thermal protection system. The test conditions are, in general, representative of Space Shuttle design flight conditions which may be more or less severe than conditions required for future space transportation systems. The results of this study are intended to help establish a preliminary data base from which the designers of future entry vehicles can evaluate the applicability of future concepts to their vehicles.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kreutzer, Cory J.; Rugh, John; Tomerlin, Jeff
Increased market penetration of electric drive vehicles (EDVs) requires overcoming a number of hurdles, including limited vehicle range and the elevated cost in comparison to conventional vehicles. Climate control loads have a significant impact on range, cutting it by over 50% in both cooling and heating conditions. To minimize the impact of climate control on EDV range, the National Renewable Energy Laboratory has partnered with Hyundai America and key industry partners to quantify the performance of thermal load reduction technologies on a Hyundai Sonata plug-in hybrid electric vehicle. Technologies that impact vehicle cabin heating in cold weather conditions and cabinmore » cooling in warm weather conditions were evaluated. Tests included thermal transient and steady-state periods for all technologies, including the development of a new test methodology to evaluate the performance of occupant thermal conditioning. Heated surfaces demonstrated significant reductions in energy use from steady-state heating, including a 29%-59% reduction from heated surfaces. Solar control glass packages demonstrated significant reductions in energy use for both transient and steady-state cooling, with up to a 42% reduction in transient and 12.8% reduction in steady-state energy use for the packages evaluated. Technologies that demonstrated significant climate control load reduction were selected for incorporation into a complete thermal load reduction package. The complete package is set to be evaluated in the second phase of the ongoing project.« less
The evaluation of speed skating helmet performance through peak linear and rotational accelerations.
Karton, Clara; Rousseau, Philippe; Vassilyadi, Michael; Hoshizaki, Thomas Blaine
2014-01-01
Like many sports involving high speeds and body contact, head injuries are a concern for short track speed skating athletes and coaches. While the mandatory use of helmets has managed to nearly eliminate catastrophic head injuries such as skull fractures and cerebral haemorrhages, they may not be as effective at reducing the risk of a concussion. The purpose of this study was to evaluate the performance characteristics of speed skating helmets with respect to managing peak linear and peak rotational acceleration, and to compare their performance against other types of helmets commonly worn within the speed skating sport. Commercially available speed skating, bicycle and ice hockey helmets were evaluated using a three-impact condition test protocol at an impact velocity of 4 m/s. Two speed skating helmet models yielded mean peak linear accelerations at a low-estimated probability range for sustaining a concussion for all three impact conditions. Conversely, the resulting mean peak rotational acceleration values were all found close to the high end of a probability range for sustaining a concussion. A similar tendency was observed for the bicycle and ice hockey helmets under the same impact conditions. Speed skating helmets may not be as effective at managing rotational acceleration and therefore may not successfully protect the user against risks associated with concussion injuries.
Blavier, Adélaïde; Gaudissart, Quentin; Cadière, Guy-Bernard; Nyssen, Anne-Sophie
2007-07-01
The purpose of this study was to evaluate the perceptual (2-dimensional [2D] vs. 3-dimensional [3D] view) and instrumental (classical vs. robotic) impacts of new robotic system on learning curves. Forty medical students without any surgical experience were randomized into 4 groups (classical laparoscopy with 3D-direct view or with 2D-indirect view, robotic system in 3D or in 2D) and repeated a laparoscopic task 6 times. After these 6 repetitions, they performed 2 trials with the same technique but in the other viewing condition (perceptive switch). Finally, subjects performed the last 3 trials with the technique they never used (technical switch). Subjects evaluated their performance answering a questionnaire (impressions of mastery, familiarity, satisfaction, self-confidence, and difficulty). Our study showed better performance and improvement in 3D view than in 2D view whatever the instrumental aspect. Participants reported less mastery, familiarity, and self-confidence and more difficulty in classical laparoscopy with 2D-indirect view than in the other conditions. Robotic surgery improves surgical performance and learning, particularly by 3D view advantage. However, perceptive and technical switches emphasize the need to adapt and pursue training also with traditional technology to prevent risks in conversion procedure.
Dopaminergic stimulation in unilateral neglect
Geminiani, G.; Bottini, G.; Sterzi, R.
1998-01-01
OBJECTIVE—To explore the hypothesis that dopaminergic circuits play a part in the premotor components of the unilateral neglect syndrome, the effects of acute dopaminergic stimulation in patients with neglect were studied. METHODS—Two tasks were evaluated before and after subcutaneous administration of apomorphine and placebo: a circle crossing test and a test of target exploration (a modified version of the bell test), performed both in perceptual (counting) and in perceptual-motor (pointing) conditions. SUBJECTS—Four patients with left neglect. RESULTS—After dopaminergic stimulation, a significant improvement was found compared with placebo administration and baseline evaluation, in the performance of the two tests. Three of the patients had a more marked improvement in the perceptual-motor condition (pointing) of the task than the perceptual condition (counting). CONCLUSIONS—The findings suggest that dopaminergic neuronal networks may mediate, in different ways, both perceptive and premotor components of the unilateral neglect syndrome. PMID:9728946
Wind-tunnel evaluation of an advanced main-rotor blade design for a utility-class helicopter
NASA Technical Reports Server (NTRS)
Yeager, William T., Jr.; Mantay, Wayne R.; Wilbur, Matthew L.; Cramer, Robert G., Jr.; Singleton, Jeffrey D.
1987-01-01
An investigation was conducted in the Langley Transonic Dynamics Tunnel to evaluate differences between an existing utility-class main-rotor blade and an advanced-design main-rotor blade. The two rotor blade designs were compared with regard to rotor performance oscillatory pitch-link loads, and 4-per-rev vertical fixed-system loads. Tests were conducted in hover and over a range of simulated full-scale gross weights and density altitude conditions at advance ratios from 0.15 to 0.40. Results indicate that the advanced blade design offers performance improvements over the baseline blade in both hover and forward flight. Pitch-link oscillatory loads for the baseline rotor were more sensitive to the test conditions than those of the advanced rotor. The 4-per-rev vertical fixed-system load produced by the advanced blade was larger than that produced by the baseline blade at all test conditions.
Wu, Xiaojun; Wang, Hongxing; Song, Bo
2015-02-10
Fog and haze can lead to changes in extinction characteristics. Therefore, the performance of the free space optical link is highly influenced by severe weather conditions. Considering the influential behavior of weather conditions, a state-of-the-art solution for the observation of fog and haze over the sea surface is presented in this paper. A Mie scattering laser radar, with a wavelength of 532 nm, is used to observe the weather conditions of the sea surface environment. The horizontal extinction coefficients and visibilities are obtained from the observation data, and the results are presented in the paper. The changes in the characteristics of extinction coefficients and visibilities are analyzed based on both the short-term (6 days) severe weather data and long-term (6 months) data. Finally, the availability performance of the free space optical communication link is evaluated under the sea surface environment.
Tomiolo, Sara; Van der Putten, Wim H; Tielbörger, Katja
2015-05-01
Altered rainfall regimes will greatly affect the response of plant species to climate change. However, little is known about how direct effects of changing precipitation on plant performance may depend on other abiotic factors and biotic interactions. We used reciprocal transplants between climatically very different sites with simultaneous manipulation of soil, plant population origin, and neighbor conditions to evaluate local adaptation and possible adaptive response of four Eastern Mediterranean annual plant species to climate change. The effect of site on plant performance was negligible, but soil origin had a strong effect on fecundity, most likely due to differential water retaining ability. Competition by neighbors strongly reduced fitness. We separated the effects of the abiotic and biotic soil properties on plant performance by repeating the field experiment in a greenhouse under homogenous environmental conditions and including a soil biota manipulation treatment. As in the field, plant performance differed among soil origins and neighbor treatments. Moreover, we found plant species-specific responses to soil biota that may be best explained by the differential sensitivity to negative and positive soil biota effects. Overall, under the conditions of our experiment with two contrasting sites, biotic interactions had a strong effect on plant fitness that interacted with and eventually overrode climate. Because climate and biotic interactions covary, reciprocal transplants and climate gradient studies should consider soil biotic interactions and abiotic conditions when evaluating climate change effects on plant performance.
NASA Astrophysics Data System (ADS)
Lexow, G. Jakob; Kluge, Marcel; Majdani, Omid; Lenarz, Thomas; Rau, Thomas S.
2017-03-01
Several research groups have proposed individual solutions for surgical assistance devices to perform minimally invasive cochlear implantation. The main challenge is the drilling of a small bore hole from the surface of the skull to the inner ear at submillimetric accuracy. Each group tested the accuracy of their device in their respective test bench or in a small number of temporal bone specimens. This complicates the comparison of the different approaches. Thus, a simple and inexpensive phantom based evaluation method is proposed which resembles clinical conditions. The method is based on half-skull phantoms made of bone-substitute material - optionally equipped with an artificial skin replica to include skin incision within the evaluation procedure. Anatomical structures of the temporal bone derived from segmentations using clinical imaging data are registered into a computer tomographic scan of the skull phantom and used for the planning of the drill trajectory. Drilling is performed with the respective device under conditions close to the intraoperative setting. Evaluation of accuracy can either be performed through postoperative imaging or by means of added targets on the inside of the skull model. Two different targets are proposed: simple reference marks only for measuring the accuracy of the device and a target containing a scala tympani model for evaluation of the complete workflow including the insertion of the electrode carrier. Experiments using the presented method take place under reproducible conditions thus allowing the comparison of the different approaches. In addition, artificial phantoms are easier to obtain and handle than human specimens.
Promoting response variability and stimulus generalization in martial arts training.
Harding, Jay W; Wacker, David P; Berg, Wendy K; Rick, Gary; Lee, John F
2004-01-01
The effects of reinforcement and extinction on response variability and stimulus generalization in the punching and kicking techniques of 2 martial arts students were evaluated across drill and sparring conditions. During both conditions, the students were asked to demonstrate different techniques in response to an instructor's punching attack. During baseline, the students received no feedback on their responses in either condition. During the intervention phase, the students received differential reinforcement in the form of instructor feedback for each different punching or kicking technique they performed during a session of the drill condition, but no reinforcement was provided for techniques in the sparring condition. Results showed that both students increased the number of different techniques they performed when reinforcement and extinction procedures were conducted during the drill condition, and that this increase in response variability generalized to the sparring condition. PMID:15293637
Effect of finite sample size on feature selection and classification: a simulation study.
Way, Ted W; Sahiner, Berkman; Hadjiiski, Lubomir M; Chan, Heang-Ping
2010-02-01
The small number of samples available for training and testing is often the limiting factor in finding the most effective features and designing an optimal computer-aided diagnosis (CAD) system. Training on a limited set of samples introduces bias and variance in the performance of a CAD system relative to that trained with an infinite sample size. In this work, the authors conducted a simulation study to evaluate the performances of various combinations of classifiers and feature selection techniques and their dependence on the class distribution, dimensionality, and the training sample size. The understanding of these relationships will facilitate development of effective CAD systems under the constraint of limited available samples. Three feature selection techniques, the stepwise feature selection (SFS), sequential floating forward search (SFFS), and principal component analysis (PCA), and two commonly used classifiers, Fisher's linear discriminant analysis (LDA) and support vector machine (SVM), were investigated. Samples were drawn from multidimensional feature spaces of multivariate Gaussian distributions with equal or unequal covariance matrices and unequal means, and with equal covariance matrices and unequal means estimated from a clinical data set. Classifier performance was quantified by the area under the receiver operating characteristic curve Az. The mean Az values obtained by resubstitution and hold-out methods were evaluated for training sample sizes ranging from 15 to 100 per class. The number of simulated features available for selection was chosen to be 50, 100, and 200. It was found that the relative performance of the different combinations of classifier and feature selection method depends on the feature space distributions, the dimensionality, and the available training sample sizes. The LDA and SVM with radial kernel performed similarly for most of the conditions evaluated in this study, although the SVM classifier showed a slightly higher hold-out performance than LDA for some conditions and vice versa for other conditions. PCA was comparable to or better than SFS and SFFS for LDA at small samples sizes, but inferior for SVM with polynomial kernel. For the class distributions simulated from clinical data, PCA did not show advantages over the other two feature selection methods. Under this condition, the SVM with radial kernel performed better than the LDA when few training samples were available, while LDA performed better when a large number of training samples were available. None of the investigated feature selection-classifier combinations provided consistently superior performance under the studied conditions for different sample sizes and feature space distributions. In general, the SFFS method was comparable to the SFS method while PCA may have an advantage for Gaussian feature spaces with unequal covariance matrices. The performance of the SVM with radial kernel was better than, or comparable to, that of the SVM with polynomial kernel under most conditions studied.
An Update on the Lithium-Ion Cell Low-Earth-Orbit Verification Test Program
NASA Technical Reports Server (NTRS)
Reid, Concha M.; Manzo, Michelle A.; Miller, Thomas B.; McKissock, Barbara I.; Bennett, William
2007-01-01
A Lithium-Ion Cell Low-Earth-Orbit Verification Test Program is being conducted by NASA Glenn Research Center to assess the performance of lithium-ion (Li-ion) cells over a wide range of low-Earth-orbit (LEO) conditions. The data generated will be used to build an empirical model for Li-ion batteries. The goal of the modeling will be to develop a tool to predict the performance and cycle life of Li-ion batteries operating at a specified set of mission conditions. Using this tool, mission planners will be able to design operation points of the battery system while factoring in mission requirements and the expected life and performance of the batteries. Test conditions for the program were selected via a statistical design of experiments to span a range of feasible operational conditions for LEO aerospace applications. The variables under evaluation are temperature, depth-of-discharge (DOD), and end-of-charge voltage (EOCV). The baseline matrix was formed by generating combinations from a set of three values for each variable. Temperature values are 10 C, 20 C and 30 C. Depth-of-discharge values are 20%, 30% and 40%. EOCV values are 3.85 V, 3.95 V, and 4.05 V. Test conditions for individual cells may vary slightly from the baseline test matrix depending upon the cell manufacturer s recommended operating conditions. Cells from each vendor are being evaluated at each of ten sets of test conditions. Cells from four cell manufacturers are undergoing life cycle tests. Life cycling on the first sets of cells began in September 2004. These cells consist of Saft 40 ampere-hour (Ah) cells and Lith ion 30 Ah cells. These cells have achieved over 10,000 cycles each, equivalent to about 20 months in LEO. In the past year, the test program has expanded to include the evaluation of Mine Safety Appliances (MSA) 50 Ah cells and ABSL battery modules. The MSA cells will begin life cycling in October 2006. The ABSL battery modules consist of commercial Sony hard carbon 18650 lithium-ion cells configured in series and parallel combinations to create nominal 14.4 volt, 3 Ah packs (4s-2p). These modules have accumulated approximately 3000 cycles. Results on the performance of the cells and modules will be presented in this paper. The life prediction and performance model for Li-ion cells in LEO will be built by analyzing the data statistically and performing regression analysis. Cells are being cycled to failure so that differences in performance trends that occur at different stages in the life of the cell can be observed and accurately modeled. Cell testing is being performed at the Naval Surface Warfare Center in Crane, IN.
STOCKPILED PRAIRIEGRASS PROVIDES HIGH-QUALITY FALL GRAZING FOR LAMBS
USDA-ARS?s Scientific Manuscript database
New varieties of prairiegrass (Bromus catharticus Vahl. = B. willdenowii Kunth.) exhibit improved persistence over ‘Matua’ under USA growing conditions, but animal performance data is lacking. We evaluated performance of lambs grazing stockpiled ‘Dixon’ prairiegrass on West Virginia hill pasture in...
Remediation management of complex sites using an adaptive site management approach.
Price, John; Spreng, Carl; Hawley, Elisabeth L; Deeb, Rula
2017-12-15
Complex sites require a disproportionate amount of resources for environmental remediation and long timeframes to achieve remediation objectives, due to their complex geologic conditions, hydrogeologic conditions, geochemical conditions, contaminant-related conditions, large scale of contamination, and/or non-technical challenges. A recent team of state and federal environmental regulators, federal agency representatives, industry experts, community stakeholders, and academia worked together as an Interstate Technology & Regulatory Council (ITRC) team to compile resources and create new guidance on the remediation management of complex sites. This article summarizes the ITRC team's recommended process for addressing complex sites through an adaptive site management approach. The team provided guidance for site managers and other stakeholders to evaluate site complexities and determine site remediation potential, i.e., whether an adaptive site management approach is warranted. Adaptive site management was described as a comprehensive, flexible approach to iteratively evaluate and adjust the remedial strategy in response to remedy performance. Key aspects of adaptive site management were described, including tools for revising and updating the conceptual site model (CSM), the importance of setting interim objectives to define short-term milestones on the journey to achieving site objectives, establishing a performance model and metrics to evaluate progress towards meeting interim objectives, and comparing actual with predicted progress during scheduled periodic evaluations, and establishing decision criteria for when and how to adapt/modify/revise the remedial strategy in response to remedy performance. Key findings will be published in an ITRC Technical and Regulatory guidance document in 2017 and free training webinars will be conducted. More information is available at www.itrc-web.org. Copyright © 2017 Elsevier Ltd. All rights reserved.
El Saadawi, Gilan M.; Tseytlin, Eugene; Legowski, Elizabeth; Jukic, Drazen; Castine, Melissa; Fine, Jeffrey; Gormley, Robert; Crowley, Rebecca S.
2009-01-01
Introduction We developed and evaluated a Natural Language Interface (NLI) for an Intelligent Tutoring System (ITS) in Diagnostic Pathology. The system teaches residents to examine pathologic slides and write accurate pathology reports while providing immediate feedback on errors they make in their slide review and diagnostic reports. Residents can ask for help at any point in the case, and will receive context-specific feedback. Research Questions We evaluated (1) the performance of our natural language system, (2) the effect of the system on learning (3) the effect of feedback timing on learning gains and (4) the effect of ReportTutor on performance to self-assessment correlations. Methods The study uses a crossover 2×2 factorial design. We recruited 20 subjects from 4 academic programs. Subjects were randomly assigned to one of the four conditions - two conditions for the immediate interface, and two for the delayed interface. An expert dermatopathologist created a reference standard and 2 board certified AP/CP pathology fellows manually coded the residents' assessment reports. Subjects were given the opportunity to self grade their performance and we used a survey to determine student response to both interfaces. Results Our results show a highly significant improvement in report writing after one tutoring session with 4-fold increase in the learning gains with both interfaces but no effect of feedback timing on performance gains. Residents who used the immediate feedback interface first experienced a feature learning gain that is correlated with the number of cases they viewed. There was no correlation between performance and self-assessment in either condition. PMID:17934789
El Saadawi, Gilan M; Tseytlin, Eugene; Legowski, Elizabeth; Jukic, Drazen; Castine, Melissa; Fine, Jeffrey; Gormley, Robert; Crowley, Rebecca S
2008-12-01
We developed and evaluated a Natural Language Interface (NLI) for an Intelligent Tutoring System (ITS) in Diagnostic Pathology. The system teaches residents to examine pathologic slides and write accurate pathology reports while providing immediate feedback on errors they make in their slide review and diagnostic reports. Residents can ask for help at any point in the case, and will receive context-specific feedback. We evaluated (1) the performance of our natural language system, (2) the effect of the system on learning (3) the effect of feedback timing on learning gains and (4) the effect of ReportTutor on performance to self-assessment correlations. The study uses a crossover 2 x 2 factorial design. We recruited 20 subjects from 4 academic programs. Subjects were randomly assigned to one of the four conditions--two conditions for the immediate interface, and two for the delayed interface. An expert dermatopathologist created a reference standard and 2 board certified AP/CP pathology fellows manually coded the residents' assessment reports. Subjects were given the opportunity to self grade their performance and we used a survey to determine student response to both interfaces. Our results show a highly significant improvement in report writing after one tutoring session with 4-fold increase in the learning gains with both interfaces but no effect of feedback timing on performance gains. Residents who used the immediate feedback interface first experienced a feature learning gain that is correlated with the number of cases they viewed. There was no correlation between performance and self-assessment in either condition.
Evaluating the Predictive Value of Growth Prediction Models
ERIC Educational Resources Information Center
Murphy, Daniel L.; Gaertner, Matthew N.
2014-01-01
This study evaluates four growth prediction models--projection, student growth percentile, trajectory, and transition table--commonly used to forecast (and give schools credit for) middle school students' future proficiency. Analyses focused on vertically scaled summative mathematics assessments, and two performance standards conditions (high…
DOE Office of Scientific and Technical Information (OSTI.GOV)
2018-01-23
Deploying an ADMS or looking to optimize its value? NREL offers a low-cost, low-risk evaluation platform for assessing ADMS performance. The National Renewable Energy Laboratory (NREL) has developed a vendor-neutral advanced distribution management system (ADMS) evaluation platform and is expanding its capabilities. The platform uses actual grid-scale hardware, large-scale distribution system models, and advanced visualization to simulate realworld conditions for the most accurate ADMS evaluation and experimentation.
Valente, Michael; Mispagel, Karen M; Tchorz, Juergen; Fabry, David
2006-06-01
Differences in performance between omnidirectional and directional microphones were evaluated between two loudspeaker conditions (single loudspeaker at 180 degrees; diffuse using eight loudspeakers set 45 degrees apart) and two types of noise (steady-state HINT noise; R-Space restaurant noise). Twenty-five participants were fit bilaterally with Phonak Perseo hearing aids using the manufacturer's recommended procedure. After wearing the hearing aids for one week, the parameters were fine-tuned based on subjective comments. Four weeks later, differences in performance between omnidirectional and directional microphones were assessed using HINT sentences presented at 0 degrees with the two types of background noise held constant at 65 dBA and under the two loudspeaker conditions. Results revealed significant differences in Reception Thresholds for Sentences (RTS in dB) where directional performance was significantly better than omnidirectional. Performance in the 180 degrees condition was significantly better than the diffuse condition, and performance was significantly better using the HINT noise in comparison to the R-Space restaurant noise. In addition, results revealed that within each loudspeaker array, performance was significantly better for the directional microphone. Looking across loudspeaker arrays, however, significant differences were not present in omnidirectional performance, but directional performance was significantly better in the 180 degrees condition when compared to the diffuse condition. These findings are discussed in terms of results reported in the past and counseling patients on the potential advantages of directional microphones as the listening situation and type of noise changes.
Indoor test for thermal performance evaluation on the Sunworks (air) solar collector
NASA Technical Reports Server (NTRS)
1978-01-01
The test procedure used and the results obtained from an evaluation test program conducted to obtain thermal performance data on a Sunworks single glazed air solar collector under simulated conditions are described. A time constant test and incident angle modifier test were conducted to determine the transient effect and the incident angle effect on the collector. These results and the results of the collector load test are also discussed.
Performance and operational improvements made to the Waukesha AT27-GL engine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reinbold, E.O.
1996-12-31
This paper presents the results of combustion and engine performance studies performed on the AT27GL lean burn engine. One study was to evaluate the effect of the pre-combustion chamber cup geometry on engine performance under several operating conditions including: Air-Fuel Ratio (AFR), ignition timing, and engine load. The study examined several combustion parameters; including IMEP, coefficient of variation of IMEP, heat release rates, and maximum combustion pressures. The study also examined engine thermal efficiency, and brake specific emissions of Oxides of Nitrogen, Carbon Monoxide, and Total Hydrocarbons (gaseous). Studies were also performed on different spark plug designs, comparing firing voltages,more » and electrode temperatures while operating under conditions of varying AFR, and ignition timing. In addition an Air-Fuel-Ratio controller was recently tested and released on the engine. The controller was tested under conditions of varying fuel quality, along with a detonation control system.« less
Computational efficiency of parallel combinatorial OR-tree searches
NASA Technical Reports Server (NTRS)
Li, Guo-Jie; Wah, Benjamin W.
1990-01-01
The performance of parallel combinatorial OR-tree searches is analytically evaluated. This performance depends on the complexity of the problem to be solved, the error allowance function, the dominance relation, and the search strategies. The exact performance may be difficult to predict due to the nondeterminism and anomalies of parallelism. The authors derive the performance bounds of parallel OR-tree searches with respect to the best-first, depth-first, and breadth-first strategies, and verify these bounds by simulation. They show that a near-linear speedup can be achieved with respect to a large number of processors for parallel OR-tree searches. Using the bounds developed, the authors derive sufficient conditions for assuring that parallelism will not degrade performance and necessary conditions for allowing parallelism to have a speedup greater than the ratio of the numbers of processors. These bounds and conditions provide the theoretical foundation for determining the number of processors required to assure a near-linear speedup.
Song, Yingchao; Luo, Haibo; Ma, Junkai; Hui, Bin; Chang, Zheng
2018-04-01
Sky detection plays an essential role in various computer vision applications. Most existing sky detection approaches, being trained on ideal dataset, may lose efficacy when facing unfavorable conditions like the effects of weather and lighting conditions. In this paper, a novel algorithm for sky detection in hazy images is proposed from the perspective of probing the density of haze. We address the problem by an image segmentation and a region-level classification. To characterize the sky of hazy scenes, we unprecedentedly introduce several haze-relevant features that reflect the perceptual hazy density and the scene depth. Based on these features, the sky is separated by two imbalance SVM classifiers and a similarity measurement. Moreover, a sky dataset (named HazySky) with 500 annotated hazy images is built for model training and performance evaluation. To evaluate the performance of our method, we conducted extensive experiments both on our HazySky dataset and the SkyFinder dataset. The results demonstrate that our method performs better on the detection accuracy than previous methods, not only under hazy scenes, but also under other weather conditions.
Park, Changhoon; Seo, Hwi Won; Kang, Ikjae; Jeong, Jiwoon; Choi, Kyuhyung; Chae, Chanhee
2014-09-01
The change in growth performance resulting from a new modified live porcine reproductive and respiratory syndrome (PRRS) vaccine was evaluated under field conditions for registration with the government as guided by the Republic of Korea's Animal and Plant Quarantine Agency. Three farms were selected based on their history of PRRS-associated respiratory diseases. On each farm, a total of 45 3-week-old pigs were randomly allocated to one of two treatment groups, (i) vaccinated (n = 25) or (ii) control (n = 20) animals. A new modified live PRRSV vaccine increased market weight by 1.26 kg/pig (104.71 kg versus 103.45 kg; P < 0.05) and decreased mortality by 17% (1.33% versus 18.33%; P < 0.05). Pathological examination indicated that vaccination effectively reduced microscopic lung lesions compared with control animals on the 3 farms. Thus, the new modified live PRRS vaccine improved growth performance and decreased mortality and lung lesions when evaluated under field conditions. Copyright © 2014, American Society for Microbiology. All Rights Reserved.
Song, Yingchao; Luo, Haibo; Ma, Junkai; Hui, Bin; Chang, Zheng
2018-01-01
Sky detection plays an essential role in various computer vision applications. Most existing sky detection approaches, being trained on ideal dataset, may lose efficacy when facing unfavorable conditions like the effects of weather and lighting conditions. In this paper, a novel algorithm for sky detection in hazy images is proposed from the perspective of probing the density of haze. We address the problem by an image segmentation and a region-level classification. To characterize the sky of hazy scenes, we unprecedentedly introduce several haze-relevant features that reflect the perceptual hazy density and the scene depth. Based on these features, the sky is separated by two imbalance SVM classifiers and a similarity measurement. Moreover, a sky dataset (named HazySky) with 500 annotated hazy images is built for model training and performance evaluation. To evaluate the performance of our method, we conducted extensive experiments both on our HazySky dataset and the SkyFinder dataset. The results demonstrate that our method performs better on the detection accuracy than previous methods, not only under hazy scenes, but also under other weather conditions. PMID:29614778
Sugi, Miho; Hagimoto, Yutaka; Nambu, Isao; Gonzalez, Alejandro; Takei, Yoshinori; Yano, Shohei; Hokari, Haruhide; Wada, Yasuhiro
2018-01-01
Recently, a brain-computer interface (BCI) using virtual sound sources has been proposed for estimating user intention via electroencephalogram (EEG) in an oddball task. However, its performance is still insufficient for practical use. In this study, we examine the impact that shortening the stimulus onset asynchrony (SOA) has on this auditory BCI. While very short SOA might improve its performance, sound perception and task performance become difficult, and event-related potentials (ERPs) may not be induced if the SOA is too short. Therefore, we carried out behavioral and EEG experiments to determine the optimal SOA. In the experiments, participants were instructed to direct attention to one of six virtual sounds (target direction). We used eight different SOA conditions: 200, 300, 400, 500, 600, 700, 800, and 1,100 ms. In the behavioral experiment, we recorded participant behavioral responses to target direction and evaluated recognition performance of the stimuli. In all SOA conditions, recognition accuracy was over 85%, indicating that participants could recognize the target stimuli correctly. Next, using a silent counting task in the EEG experiment, we found significant differences between target and non-target sound directions in all but the 200-ms SOA condition. When we calculated an identification accuracy using Fisher discriminant analysis (FDA), the SOA could be shortened by 400 ms without decreasing the identification accuracies. Thus, improvements in performance (evaluated by BCI utility) could be achieved. On average, higher BCI utilities were obtained in the 400 and 500-ms SOA conditions. Thus, auditory BCI performance can be optimized for both behavioral and neurophysiological responses by shortening the SOA. PMID:29535602
Urine Pretreatment History and Perspective in NASA Human Spaceflight
NASA Technical Reports Server (NTRS)
Anderson, Molly; Adam, Niklas; Chambers, Antja; Broyan, James
2015-01-01
Urine pretreatment is a technology that may seem to have small mass impacts in future spaceflight missions, but can have significant impacts on reliability, life, and performance of the rest of the wastewater management and recovery systems. NASA has experience with several different urine pretreatment systems, including those flow on the space shuttle, evaluated for NASA waste collection systems or used in Russian commodes on ISS, or developed by NASA or industry as alternatives. Each has had unique requirements for shelf life, operational life, and the life or conditions of the stored, treated urine. Each was evaluated under different test conditions depending on mission, and depending on testing experience developed over NASA's history. Those that were flown led to further lessons learned about hardware compatibility and control. As NASA looks forward to human spaceflight missions beyond low Earth orbit, these techniques need to be evaluated in new light. Based on published design reference missions, candidate requirements can be derived for future systems. Initial comparisons between these requirements and previous performance or test results can be performed. In many cases these comparisons reveal data gaps. Successful previous performance is not enough to address current needs.
Muthuraj, Muthusivaramapandian; Kumar, Vikram; Palabhanvi, Basavaraj; Das, Debasish
2014-03-01
The present study reports evaluation of an indigenous microalgal isolate Chlorella sp. FC2 IITG as a potential candidate for biodiesel production. Characterization of the strain was performed under photoautotrophic, heterotrophic, and mixotrophic cultivation conditions. Further, an open-pond cultivation of the strain under outdoor conditions was demonstrated to evaluate growth performance and lipid productivity under fluctuating environmental parameters and in the presence of potential contaminants. The key findings were: (1) the difference in cultivation conditions resulted in significant variation in the biomass productivity (73-114 mg l⁻¹ day⁻¹) and total lipid productivity (35.02-50.42 mg l⁻¹ day⁻¹) of the strain; (2) nitrate and phosphate starvation were found to be the triggers for lipid accumulation in the cell mass; (3) open-pond cultivation of the strain under outdoor conditions resulted in biomass productivity of 44 mg l⁻¹ day⁻¹ and total lipid productivity of 10.7 mg l⁻¹ day⁻¹; (4) a maximum detectable bacterial contamination of 7 % of the total number of cells was recorded in an open-pond system; and (5) fatty acid profiling revealed abundance of palmitic acid (C16:0), oleic acid (C18:1) and linoleic acid (C18:2), which are considered to be the key elements for suitable quality biodiesel.
NASA Technical Reports Server (NTRS)
Putnam, Jacob P.; Untaroiu, Costin; Somers. Jeffrey
2014-01-01
In an effort to develop occupant protection standards for future multipurpose crew vehicles, the National Aeronautics and Space Administration (NASA) has looked to evaluate the test device for human occupant restraint with the modification kit (THOR-K) anthropomorphic test device (ATD) in relevant impact test scenarios. With the allowance and support of the National Highway Traffic Safety Administration, NASA has performed a series of sled impact tests on the latest developed THOR-K ATD. These tests were performed to match test conditions from human volunteer data previously collected by the U.S. Air Force. The objective of this study was to evaluate the THOR-K finite element (FE) model and the Total HUman Model for Safety (THUMS) FE model with respect to the tests performed. These models were evaluated in spinal and frontal impacts against kinematic and kinetic data recorded in ATD and human testing. Methods: The FE simulations were developed based on recorded pretest ATD/human position and sled acceleration pulses measured during testing. Predicted responses by both human and ATD models were compared to test data recorded under the same impact conditions. The kinematic responses of the models were quantitatively evaluated using the ISO-metric curve rating system. In addition, ATD injury criteria and human stress/strain data were calculated to evaluate the risk of injury predicted by the ATD and human model, respectively. Results: Preliminary results show well-correlated response between both FE models and their physical counterparts. In addition, predicted ATD injury criteria and human model stress/strain values are shown to positively relate. Kinematic comparison between human and ATD models indicates promising biofidelic response, although a slightly stiffer response is observed within the ATD. Conclusion: As a compliment to ATD testing, numerical simulation provides efficient means to assess vehicle safety throughout the design process and further improve the design of physical ATDs. The assessment of the THOR-K and THUMS FE models in a spaceflight testing condition is an essential first step to implementing these models in the computational evaluation of spacecraft occupant safety. Promising results suggest future use of these models in the aerospace field.
Design and Evaluation of a Proxy-Based Monitoring System for OpenFlow Networks.
Taniguchi, Yoshiaki; Tsutsumi, Hiroaki; Iguchi, Nobukazu; Watanabe, Kenzi
2016-01-01
Software-Defined Networking (SDN) has attracted attention along with the popularization of cloud environment and server virtualization. In SDN, the control plane and the data plane are decoupled so that the logical topology and routing control can be configured dynamically depending on network conditions. To obtain network conditions precisely, a network monitoring mechanism is necessary. In this paper, we focus on OpenFlow which is a core technology to realize SDN. We propose, design, implement, and evaluate a network monitoring system for OpenFlow networks. Our proposed system acts as a proxy between an OpenFlow controller and OpenFlow switches. Through experimental evaluations, we confirm that our proposed system can capture packets and monitor traffic information depending on administrator's configuration. In addition, we show that our proposed system does not influence significant performance degradation to overall network performance.
New Automotive Air Conditioning System Simulation Tool Developed in MATLAB/Simulink
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kiss, T.; Chaney, L.; Meyer, J.
Further improvements in vehicle fuel efficiency require accurate evaluation of the vehicle's transient total power requirement. When operated, the air conditioning (A/C) system is the largest auxiliary load on a vehicle; therefore, accurate evaluation of the load it places on the vehicle's engine and/or energy storage system is especially important. Vehicle simulation software, such as 'Autonomie,' has been used by OEMs to evaluate vehicles' energy performance. A transient A/C simulation tool incorporated into vehicle simulation models would also provide a tool for developing more efficient A/C systems through a thorough consideration of the transient A/C system performance. The dynamic systemmore » simulation software Matlab/Simulink was used to develop new and more efficient vehicle energy system controls. The various modeling methods used for the new simulation tool are described in detail. Comparison with measured data is provided to demonstrate the validity of the model.« less
3500-hour durability testing of ceramic materials for automotive gas turbine engines
NASA Technical Reports Server (NTRS)
Carruthers, W. D.; Richerson, D. W.; Benn, K. W.
1980-01-01
A two-year durability program was performed by AiResearch Phoenix to evaluate four commercially available ceramic materials under simulated automotive gas turbine combustor discharge conditions. These conditions included extended cyclic thermal exposures up to 2500 F and 3500 hr. The four materials selected for evaluation were Norton NCX-34 hot pressed silicon nitride, AiResearch RBN 101 reaction bonded silicon nitride, Carborundum pressureless sintered alpha-SiC and Pure Carbon Co. (British Nuclear Fuels, Ltd.) Refel reaction sintered silicon carbide. These materials were initially exposed to 350 hr/1750 cycles at 1200 and 1370 C. Subsequent exposures to 1050, 2100 and 3500 hr were performed on those materials maintaining 50% of baseline strength after the initial exposure. Additional evaluations of exposed bars included dimensional and weight changes, dye penetrant, specific damping capacity changes, SEM fractography, and X-ray diffraction.
NASA Technical Reports Server (NTRS)
Shahidi, Anoosh K.; Schlegelmilch, Richard F.; Petrik, Edward J.; Walters, Jerry L.
1991-01-01
A software application to assist end-users of the link evaluation terminal (LET) for satellite communications is being developed. This software application incorporates artificial intelligence (AI) techniques and will be deployed as an interface to LET. The high burst rate (HBR) LET provides 30 GHz transmitting/20 GHz receiving (220/110 Mbps) capability for wideband communications technology experiments with the Advanced Communications Technology Satellite (ACTS). The HBR LET can monitor and evaluate the integrity of the HBR communications uplink and downlink to the ACTS satellite. The uplink HBR transmission is performed by bursting the bit-pattern as a modulated signal to the satellite. The HBR LET can determine the bit error rate (BER) under various atmospheric conditions by comparing the transmitted bit pattern with the received bit pattern. An algorithm for power augmentation will be applied to enhance the system's BER performance at reduced signal strength caused by adverse conditions.
Design and Evaluation of a Proxy-Based Monitoring System for OpenFlow Networks
Taniguchi, Yoshiaki; Tsutsumi, Hiroaki; Iguchi, Nobukazu; Watanabe, Kenzi
2016-01-01
Software-Defined Networking (SDN) has attracted attention along with the popularization of cloud environment and server virtualization. In SDN, the control plane and the data plane are decoupled so that the logical topology and routing control can be configured dynamically depending on network conditions. To obtain network conditions precisely, a network monitoring mechanism is necessary. In this paper, we focus on OpenFlow which is a core technology to realize SDN. We propose, design, implement, and evaluate a network monitoring system for OpenFlow networks. Our proposed system acts as a proxy between an OpenFlow controller and OpenFlow switches. Through experimental evaluations, we confirm that our proposed system can capture packets and monitor traffic information depending on administrator's configuration. In addition, we show that our proposed system does not influence significant performance degradation to overall network performance. PMID:27006977
Postflight hardware evaluation 360T026 (RSRM-26, STS-47)
NASA Technical Reports Server (NTRS)
Nielson, Greg
1993-01-01
The final report for the Clearfield disassembly evaluation and a continuation of the KSC postflight assessment for the 360T026 (STS-47) Redesigned Solid Rocket Motor (RSRM) flight set is provided. All observed hardware conditions were documented on PFOR's and are included in Appendices A, B, and C. Appendices D and E contain the measurements and safety factor data for the nozzle and insulation components. This report, along with the KSC Ten-Day Postflight Hardware Evaluation Report (TWR-64203), represents a summary of the 360T026 hardware evaluation. The as-flown hardware configuration is documented in TWR-60472. Disassembly evaluation photograph numbers are logged in TWA-1987. The 360T026 flight set disassembly evaluations described were performed at the RSRM Refurbishment Facility in Clearfield, Utah. The final factory joint demate occurred on 12 April 1993. Detailed evaluations were performed in accordance with the Clearfield Postflight Engineering Evaluation Plan (PEEP), TWR-50051, Revision A. All observations were compared against limits that are also defined in the PEEP. These limits outline the criteria for categorizing the observations as acceptable, reportable, or critical. Hardware conditions that were unexpected and/or determined to be reportable or critical were evaluated by the applicable CPT and tracked through the PFAR system.
de Witte, Annemarie M H; Sjaarda, Fleur; Helleman, Jochem; Berger, Monique A M; van der Woude, Lucas H V; Hoozemans, Marco J M
2018-06-15
The Wheelchair Mobility Performance (WMP) test is a reliable and valid measure to assess mobility performance in wheelchair basketball. The aim of this study was to examine the sensitivity to change of the WMP test by manipulating wheelchair configurations. Sixteen wheelchair basketball players performed the WMP test 3 times in their own wheelchair: (i) without adjustments ("control condition"); (ii) with 10 kg additional mass ("weighted condition"); and (iii) with 50% reduced tyre pressure ("tyre condition"). The outcome measure was time (s). If paired t-tests were significant (p <0.05) and differences between conditions were larger than the standard error of measurement, the effect sizes (ES) were used to evaluate the sensitivity to change. ES values ≥0.2 were regarded as sensitive to change. The overall performance times for the manipulations were significantly higher than the control condition, with mean differences of 4.40 s (weight - control, ES = 0.44) and 2.81 s (tyre - control, ES = 0.27). The overall performance time on the WMP test was judged as sensitive to change. For 8 of the 15 separate tasks on the WMP test, the tasks were judged as sensitive to change for at least one of the manipulations. The WMP test can detect change in mobility performance when wheelchair configurations are manipulated.
Romero-Flores, Adrian; McConnell, Laura L; Hapeman, Cathleen J; Ramirez, Mark; Torrents, Alba
2017-11-01
Electronic noses have been widely used in the food industry to monitor process performance and quality control, but use in wastewater and biosolids treatment has not been fully explored. Therefore, we examined the feasibility of an electronic nose to discriminate between treatment conditions of alkaline stabilized biosolids and compared its performance with quantitative analysis of key odorants. Seven lime treatments (0-30% w/w) were prepared and the resultant off-gas was monitored by GC-MS and by an electronic nose equipped with ten metal oxide sensors. A pattern recognition model was created using linear discriminant analysis (LDA) and principal component analysis (PCA) of the electronic nose data. In general, LDA performed better than PCA. LDA showed clear discrimination when single tests were evaluated, but when the full data set was included, discrimination between treatments was reduced. Frequency of accurate recognition was tested by three algorithms with Euclidan and Mahalanobis performing at 81% accuracy and discriminant function analysis at 70%. Concentrations of target compounds by GC-MS were in agreement with those reported in literature and helped to elucidate the behavior of the pattern recognition via comparison of individual sensor responses to different biosolids treatment conditions. Results indicated that the electronic nose can discriminate between lime percentages, thus providing the opportunity to create classes of under-dosed and over-dosed relative to regulatory requirements. Full scale application will require careful evaluation to maintain accuracy under variable process and environmental conditions. Copyright © 2017 Elsevier Ltd. All rights reserved.
Psychophysiological Assessment in Pilots Performing Challenging Simulated and Real Flight Maneuvers.
Johannes, Bernd; Rothe, Stefanie; Gens, André; Westphal, Soeren; Birkenfeld, Katja; Mulder, Edwin; Rittweger, Jörn; Ledderhos, Carla
2017-09-01
The objective assessment of psychophysiological arousal during challenging flight maneuvers is of great interest to aerospace medicine, but remains a challenging task. In the study presented here, a vector-methodological approach was used which integrates different psychophysiological variables, yielding an integral arousal index called the Psychophysiological Arousal Value (PAV). The arousal levels of 15 male pilots were assessed during predetermined, well-defined flight maneuvers performed under simulated and real flight conditions. The physiological data, as expected, revealed inter- and intra-individual differences for the various measurement conditions. As indicated by the PAV, air-to-air refueling (AAR) turned out to be the most challenging task. In general, arousal levels were comparable between simulator and real flight conditions. However, a distinct difference was observed when the pilots were divided by instructors into two groups based on their proficiency in AAR with AWACS (AAR-Novices vs. AAR-Professionals). AAR-Novices had on average more than 2000 flight hours on other aircrafts. They showed higher arousal reactions to AAR in real flight (contact: PAV score 8.4 ± 0.37) than under simulator conditions (7.1 ± 0.30), whereas AAR-Professionals did not (8.5 ± 0.46 vs. 8.8 ± 0.80). The psychophysiological arousal value assessment was tested in field measurements, yielding quantifiable arousal differences between proficiency groups of pilots during simulated and real flight conditions. The method used in this study allows an evaluation of the psychophysiological cost during a certain flying performance and thus is possibly a valuable tool for objectively evaluating the actual skill status of pilots.Johannes B, Rothe S, Gens A, Westphal S, Birkenfeld K, Mulder E, Rittweger J, Ledderhos C. Psychophysiological assessment in pilots performing challenging simulated and real flight maneuvers. Aerosp Med Hum Perform. 2017; 88(9):834-840.
NASA Technical Reports Server (NTRS)
1989-01-01
Loredan Biomedical, Inc.'s LIDO, a computerized physical therapy system, was purchased by NASA in 1985 for evaluation as a Space Station Freedom exercise program. In 1986, while involved in an ARC muscle conditioning project, Malcom Bond, Loredan's chairman, designed an advanced software package for NASA which became the basis for LIDOSOFT software used in the commercially available system. The system employs a "proprioceptive" software program which perceives internal body conditions, induces perturbations to muscular effort and evaluates the response. Biofeedback on a screen allows a patient to observe his own performance.
Resilient Monitoring Systems: Architecture, Design, and Application to Boiler/Turbine Plant
Garcia, Humberto E.; Lin, Wen-Chiao; Meerkov, Semyon M.; ...
2014-11-01
Resilient monitoring systems, considered in this paper, are sensor networks that degrade gracefully under malicious attacks on their sensors, causing them to project misleading information. The goal of this work is to design, analyze, and evaluate the performance of a resilient monitoring system intended to monitor plant conditions (normal or anomalous). The architecture developed consists of four layers: data quality assessment, process variable assessment, plant condition assessment, and sensor network adaptation. Each of these layers is analyzed by either analytical or numerical tools. The performance of the overall system is evaluated using a simplified boiler/turbine plant. The measure of resiliencymore » is quantified using Kullback-Leibler divergence, and is shown to be sufficiently high in all scenarios considered.« less
Resilient monitoring systems: architecture, design, and application to boiler/turbine plant.
Garcia, Humberto E; Lin, Wen-Chiao; Meerkov, Semyon M; Ravichandran, Maruthi T
2014-11-01
Resilient monitoring systems, considered in this paper, are sensor networks that degrade gracefully under malicious attacks on their sensors, causing them to project misleading information. The goal of this paper is to design, analyze, and evaluate the performance of a resilient monitoring system intended to monitor plant conditions (normal or anomalous). The architecture developed consists of four layers: data quality assessment, process variable assessment, plant condition assessment, and sensor network adaptation. Each of these layers is analyzed by either analytical or numerical tools. The performance of the overall system is evaluated using a simplified boiler/turbine plant. The measure of resiliency is quantified based on the Kullback-Leibler divergence and shown to be sufficiently high in all scenarios considered.
Implementation of a WRF-CMAQ Air Quality Modeling System in Bogotá, Colombia
NASA Astrophysics Data System (ADS)
Nedbor-Gross, R.; Henderson, B. H.; Pachon, J. E.; Davis, J. R.; Baublitz, C. B.; Rincón, A.
2014-12-01
Due to a continuous economic growth Bogotá, Colombia has experienced air pollution issues in recent years. The local environmental authority has implemented several strategies to curb air pollution that have resulted in the decrease of PM10 concentrations since 2010. However, more activities are necessary in order to meet international air quality standards in the city. The University of Florida Air Quality and Climate group is collaborating with the Universidad de La Salle to prioritize regulatory strategies for Bogotá using air pollution simulations. To simulate pollution, we developed a modeling platform that combines the Weather Research and Forecasting Model (WRF), local emissions, and the Community Multi-scale Air Quality model (CMAQ). This platform is the first of its kind to be implemented in the megacity of Bogota, Colombia. The presentation will discuss development and evaluation of the air quality modeling system, highlight initial results characterizing photochemical conditions in Bogotá, and characterize air pollution under proposed regulatory strategies. The WRF model has been configured and applied to Bogotá, which resides in a tropical climate with complex mountainous topography. Developing the configuration included incorporation of local topography and land-use data, a physics sensitivity analysis, review, and systematic evaluation. The threshold, however, was set based on synthesis of model performance under less mountainous conditions. We will evaluate the impact that differences in autocorrelation contribute to the non-ideal performance. Air pollution predictions are currently under way. CMAQ has been configured with WRF meteorology, global boundary conditions from GEOS-Chem, and a locally produced emission inventory. Preliminary results from simulations show promising performance of CMAQ in Bogota. Anticipated results include a systematic performance evaluation of ozone and PM10, characterization of photochemical sensitivity, and air quality predictions under proposed regulatory scenarios.
NASA Astrophysics Data System (ADS)
Singh, G.; Sweet, R.; Brown, N. R.; Wirth, B. D.; Katoh, Y.; Terrani, K.
2018-02-01
SiC/SiC composites are candidates for accident tolerant fuel cladding in light water reactors. In the extreme nuclear reactor environment, SiC-based fuel cladding will be exposed to neutron damage, significant heat flux, and a corrosive environment. To ensure reliable and safe operation of accident tolerant fuel cladding concepts such as SiC-based materials, it is important to assess thermo-mechanical performance under in-reactor conditions including irradiation and realistic temperature distributions. The effect of non-uniform dimensional changes caused by neutron irradiation with spatially varying temperatures, along with the closing of the fuel-cladding gap, on the stress development in the cladding over the course of irradiation were evaluated. The effect of non-uniform circumferential power profile in the fuel rod on the mechanical performance of the cladding is also evaluated. These analyses have been performed using the BISON fuel performance modeling code and the commercial finite element analysis code Abaqus. A constitutive model is constructed and solved numerically to predict the stress distribution in the cladding under normal operating conditions. The dependence of dimensions and thermophysical properties on irradiation dose and temperature has been incorporated into the models. Initial scoping results from parametric analyses provide time varying stress distributions in the cladding as well as the interaction of fuel rod with the cladding under different conditions of initial fuel rod-cladding gap and linear heat rate. It is found that a non-uniform circumferential power profile in the fuel rod may cause significant lateral bowing in the cladding, and motivates further analysis and evaluation.
Gast, Anne; Werner, Benedikt; Heitmann, Christina; Spruyt, Adriaan; Rothermund, Klaus
2014-01-01
In two experiments, we assessed evaluative priming effects in a task that was unrelated to the congruent or incongruent stimulus pairs. In each trial, participants saw two valent (positive or negative) pictures that formed evaluatively congruent or incongruent stimulus pairs and a letter that was superimposed on the second picture. Different from typical evaluative priming studies, participants were not required to respond to the second of the valent stimuli, but asked to categorize the letter that was superimposed on the second picture. We assessed the impact of the evaluative (in)congruency of the two pictures on the performance in responding to the letter. In addition, we manipulated attention to the evaluative dimension by asking participants in one experimental group to respond to the valence of the pictures on a subset of trials (evaluative task condition). In both experiments, we found evaluative priming effects in letter categorization responses: Participants categorized the letter faster (and sometimes more correctly) in trials with congruent picture-pairs. These effects were present only in the evaluative task condition. These findings can be explained with different resource-based accounts of evaluative priming and the additional assumption that attention to valence is necessary for evaluative congruency to affect processing resources. According to resource-based accounts valence-incongruent trials require more cognitive resources than valence-congruent trials (e.g., Hermans, Van den Broeck, & Eelen, 1998).
Noh, Yun Hong; Jeong, Do Un
2014-07-15
In this paper, a packet generator using a pattern matching algorithm for real-time abnormal heartbeat detection is proposed. The packet generator creates a very small data packet which conveys sufficient crucial information for health condition analysis. The data packet envelopes real time ECG signals and transmits them to a smartphone via Bluetooth. An Android application was developed specifically to decode the packet and extract ECG information for health condition analysis. Several graphical presentations are displayed and shown on the smartphone. We evaluate the performance of abnormal heartbeat detection accuracy using the MIT/BIH Arrhythmia Database and real time experiments. The experimental result confirm our finding that abnormal heart beat detection is practically possible. We also performed data compression ratio and signal restoration performance evaluations to establish the usefulness of the proposed packet generator and the results were excellent.
Damage evaluation by a guided wave-hidden Markov model based method
NASA Astrophysics Data System (ADS)
Mei, Hanfei; Yuan, Shenfang; Qiu, Lei; Zhang, Jinjin
2016-02-01
Guided wave based structural health monitoring has shown great potential in aerospace applications. However, one of the key challenges of practical engineering applications is the accurate interpretation of the guided wave signals under time-varying environmental and operational conditions. This paper presents a guided wave-hidden Markov model based method to improve the damage evaluation reliability of real aircraft structures under time-varying conditions. In the proposed approach, an HMM based unweighted moving average trend estimation method, which can capture the trend of damage propagation from the posterior probability obtained by HMM modeling is used to achieve a probabilistic evaluation of the structural damage. To validate the developed method, experiments are performed on a hole-edge crack specimen under fatigue loading condition and a real aircraft wing spar under changing structural boundary conditions. Experimental results show the advantage of the proposed method.
Tests of a D vented thrust deflecting nozzle behind a simulated turbofan engine
NASA Technical Reports Server (NTRS)
Watson, T. L.
1982-01-01
A D vented thrust deflecting nozzle applicable to subsonic V/STOL aircraft was tested behind a simulated turbofan engine in the verticle thrust stand. Nozzle thrust, fan operating characteristics, nozzle entrance conditions, and static pressures were measured. Nozzle performance was measured for variations in exit area and thrust deflection angle. Six core nozzle configurations, the effect of core exit axial location, mismatched core and fan stream nozzle pressure ratios, and yaw vane presence were evaluated. Core nozzle configuration affected performance at normal and engine out operating conditions. Highest vectored nozzle performance resulted for a given exit area when core and fan stream pressure were equal. Its is concluded that high nozzle performance can be maintained at both normal and engine out conditions through control of the nozzle entrance Mach number with a variable exit area.
An evaluation of the performance of concretes containing fly ash and ground slag in bridge decks.
DOT National Transportation Integrated Search
2006-01-01
Cores from 36 bridge decks were evaluated to assess the condition and quality of the concrete by petrographic methods and direct and indirect measures of the transport properties. Transport properties were measured by a rate of absorption test (ASTM ...
DOT National Transportation Integrated Search
1973-01-01
Various curing and/or protective coatings were evaluated under three conditions: (1) accelerated laboratory freezing and thawing of specimens in 2 percent sodium chloride solution, (2) exposure in an outdoor area of slabs which were subjected to cont...
DOT National Transportation Integrated Search
1975-01-01
Various curing and/or protective coatings were evaluated under three conditions: (1) accelerated laboratory freezing and thawing of specimens in 2 percent sodium chloride solution, (2) exposure in an outdoor area of slabs subjected to controlled appl...
Sleep restriction during simulated wildfire suppression: effect on physical task performance.
Vincent, Grace; Ferguson, Sally A; Tran, Jacqueline; Larsen, Brianna; Wolkow, Alexander; Aisbett, Brad
2015-01-01
To examine the effects of sleep restriction on firefighters' physical task performance during simulated wildfire suppression. Thirty-five firefighters were matched and randomly allocated to either a control condition (8-hour sleep opportunity, n = 18) or a sleep restricted condition (4-hour sleep opportunity, n = 17). Performance on physical work tasks was evaluated across three days. In addition, heart rate, core temperature, and worker activity were measured continuously. Rate of perceived and exertion and effort sensation were evaluated during the physical work periods. There were no differences between the sleep-restricted and control groups in firefighters' task performance, heart rate, core temperature, or perceptual responses during self-paced simulated firefighting work tasks. However, the sleep-restricted group were less active during periods of non-physical work compared to the control group. Under self-paced work conditions, 4 h of sleep restriction did not adversely affect firefighters' performance on physical work tasks. However, the sleep-restricted group were less physically active throughout the simulation. This may indicate that sleep-restricted participants adapted their behaviour to conserve effort during rest periods, to subsequently ensure they were able to maintain performance during the firefighter work tasks. This work contributes new knowledge to inform fire agencies of firefighters' operational capabilities when their sleep is restricted during multi-day wildfire events. The work also highlights the need for further research to explore how sleep restriction affects physical performance during tasks of varying duration, intensity, and complexity.
Sleep Restriction during Simulated Wildfire Suppression: Effect on Physical Task Performance
Vincent, Grace; Ferguson, Sally A.; Tran, Jacqueline; Larsen, Brianna; Wolkow, Alexander; Aisbett, Brad
2015-01-01
Objectives To examine the effects of sleep restriction on firefighters’ physical task performance during simulated wildfire suppression. Methods Thirty-five firefighters were matched and randomly allocated to either a control condition (8-hour sleep opportunity, n = 18) or a sleep restricted condition (4-hour sleep opportunity, n = 17). Performance on physical work tasks was evaluated across three days. In addition, heart rate, core temperature, and worker activity were measured continuously. Rate of perceived and exertion and effort sensation were evaluated during the physical work periods. Results There were no differences between the sleep-restricted and control groups in firefighters’ task performance, heart rate, core temperature, or perceptual responses during self-paced simulated firefighting work tasks. However, the sleep-restricted group were less active during periods of non-physical work compared to the control group. Conclusions Under self-paced work conditions, 4 h of sleep restriction did not adversely affect firefighters’ performance on physical work tasks. However, the sleep-restricted group were less physically active throughout the simulation. This may indicate that sleep-restricted participants adapted their behaviour to conserve effort during rest periods, to subsequently ensure they were able to maintain performance during the firefighter work tasks. This work contributes new knowledge to inform fire agencies of firefighters’ operational capabilities when their sleep is restricted during multi-day wildfire events. The work also highlights the need for further research to explore how sleep restriction affects physical performance during tasks of varying duration, intensity, and complexity. PMID:25615988
NASA Astrophysics Data System (ADS)
Pandey, Gavendra; Sharan, Maithili
2018-01-01
Application of atmospheric dispersion models in air quality analysis requires a proper representation of the vertical and horizontal growth of the plume. For this purpose, various schemes for the parameterization of dispersion parameters σ‧s are described in both stable and unstable conditions. These schemes differ on the use of (i) extent of availability of on-site measurements (ii) formulations developed for other sites and (iii) empirical relations. The performance of these schemes is evaluated in an earlier developed IIT (Indian Institute of Technology) dispersion model with the data set in single and multiple releases conducted at Fusion Field Trials, Dugway Proving Ground, Utah 2007. Qualitative and quantitative evaluation of the relative performance of all the schemes is carried out in both stable and unstable conditions in the light of (i) peak/maximum concentrations, and (ii) overall concentration distribution. The blocked bootstrap resampling technique is adopted to investigate the statistical significance of the differences in performances of each of the schemes by computing 95% confidence limits on the parameters FB and NMSE. The various analysis based on some selected statistical measures indicated consistency in the qualitative and quantitative performances of σ schemes. The scheme which is based on standard deviation of wind velocity fluctuations and Lagrangian time scales exhibits a relatively better performance in predicting the peak as well as the lateral spread.
Evaluation of Sc-Bearing Aluminum Alloy C557 for Aerospace Applications
NASA Technical Reports Server (NTRS)
Domack, Marcia S.; Dicus, Dennis L.
2002-01-01
The performance of the Al-Mg-Sc alloy C557 was evaluated to assess its potential for a broad range of aerospace applications, including airframe and launch vehicle structures. Of specific interest were mechanical properties at anticipated service temperatures and thermal stability of the alloy. Performance was compared with conventional airframe aluminum alloys and with other emerging aluminum alloys developed for specific service environments. Mechanical properties and metallurgical structure were evaluated for commercially rolled sheet in the as-received H116 condition and after thermal exposures at 107 C. Metallurgical analyses were performed to de.ne grain morphology and texture, strengthening precipitates, and to assess the effect of thermal exposure.
NASA Technical Reports Server (NTRS)
Yen, Judy C. H.; Tomsik, Thomas M.
2004-01-01
This paper describes the results of a series of catalyst screening tests conducted with Jet-A fuel under auto-thermal reforming (ATR) process conditions at the research laboratories of SOFCo-EFS Holdings LLC under Glenn Research Center Contract. The primary objective is to identify best available catalysts for future testing at the NASA GRC 10-kW(sub e) reformer test facility. The new GRC reformer-injector test rig construction is due to complete by March 2004. Six commercially available monolithic catalyst materials were initially selected by the NASA/SOFCo team for evaluation and bench scale screening in an existing 0.05 kW(sub e) microreactor test apparatus. The catalyst screening tests performed lasted 70 to 100 hours in duration in order to allow comparison between the different samples over a defined range of ATR process conditions. Aging tests were subsequently performed with the top two ranked catalysts as a more representative evaluation of performance in a commercial aerospace application. The two catalyst aging tests conducted lasting for approximately 600 hours and 1000 hours, respectively.
NASA Technical Reports Server (NTRS)
Kessel, Kurt R.
2016-01-01
Determine the suitability of trivalent chromium conversion coatings that meet the requirements of MIL-DTL-5541, Type II, for use in applications where high-frequency electrical performance is important. Evaluate the ability of hexavalent chrome free pretreated aluminum to form adequate EMI seals, and maintain that seal while being subjected to harsh environmental conditions. Assess the performance of trivalent chromium pretreatments against a known control hexavalent chrome pretreatment before and after they have been exposed to a set of environmental conditions. It is known that environmental testing causes a decrease in shielding effectiveness when hexavalent chrome pretreatments are used (Alodine 1200s). Need to determine how shielding effectiveness will be affected with the use of hexavalent chrome free pretreatments. Performance will be assessed by evaluating shielding effectiveness (SE) test data from a variety of test samples comprised of different aluminum types and/or conversion coatings. The formation of corrosion will be evaluated between the mating surfaces and gasket to assess the corrosion resistant properties of the pretreatments, comparing the hexavalent control to the hexavalent chrome free pretreatments.
Discriminative Dissolution Method for Benzoyl Metronidazole Oral Suspension.
da Silva, Aline Santos; da Rosa Silva, Carlos Eduardo; Paula, Fávero Reisdorfer; da Silva, Fabiana Ernestina Barcellos
2016-06-01
A dissolution method for benzoyl metronidazole (BMZ) oral suspensions was developed and validated using a high-performance liquid chromatography (HPLC) method. After determination of sink conditions, dissolution profiles were evaluated using different dissolution media and agitation speeds. The sample insertion mode in dissolution media was also evaluated. The best conditions were obtained using a paddle, 50 rpm stirring speed, simulated gastric fluid (without pepsin) as the dissolution medium, and sample insertion by a syringe. These conditions were suitable for providing sink conditions and discriminatory power between different formulations. Through the tested conditions, the results can be considered specific, linear, precise, accurate, and robust. The dissolution profiles of five samples were compared using the similarity factor (f 2) and dissolution efficiency. The dissolution kinetics were evaluated and described by the Weibull model. Whereas there is no monograph for this pharmaceutical formulation, the dissolution method proposed can be considered suitable for quality control and dissolution profile comparison of different commercial formulations.
Thermal Evaluation of Fiber Bragg Gratings at Extreme Temperatures
NASA Technical Reports Server (NTRS)
Juergens, Jeffrey; Adamovsky, Grigory; Bhatt, Ramakrishna; Morscher, Gregory; Floyd, Bertram
2005-01-01
The development of integrated fiber optic sensors for use in aerospace health monitoring systems demands that the sensors be able to perform in extreme environments. In order to use fiber optic sensors effectively in an extreme environment one must have a thorough understanding of the sensor's capabilities, limitations, and performance under extreme environmental conditions. This paper reports on our current sensor evaluation examining the performance of freestanding fiber Bragg gratings (FBG) at extreme temperatures. While the ability of FBGs to survive at extreme temperatures has been established, their performance and long term survivability is not well documented. At extreme temperatures the grating structure would be expected to dissipate, degrading the sensors performance and eventually ceasing to return a detectable signal. The fiber jacket will dissipate leaving a brittle, unprotected fiber. For FBGs to be used in aerospace systems their performance and limitations need to be thoroughly understood at extreme temperatures. As the limits of the FBGs performance are pushed the long term survivability and performance of the sensor comes into question. We will not only examine the ability of FBGs to survive extreme temperatures but also look at their performance during many thermal cycles. This paper reports on test results of the performance of thermal cycling commercially available FBGs, at temperatures up to 1000 C, seen in aerospace applications. Additionally this paper will report on the performance of commercially available FBGs held at 1000 C for hundreds of hours. Throughout the evaluation process, various parameters of the FBGs performance were monitored and recorded. Several test samples were subjected to identical test conditions to allow for statistical analysis of the data. Test procedures, calibrations, referencing techniques, performance data, and interpretations and explanations of results are presented in the paper along with directions for future research.
Broeckhoven, K.; Cabooter, D.; Desmet, G.
2012-01-01
The reintroduction of superficially porous particles has resulted in a leap forward for the separation performance in liquid chromatography. The underlying reasons for the higher efficiency of columns packed with these particles are discussed. The performance of the newly introduced 5 μm superficially porous particles is evaluated and compared to 2.7 μm superficially porous and 3.5 and 5 μm fully porous columns using typical test compounds (alkylphenones) and a relevant pharmaceutical compound (impurity of amoxicillin). The 5 μm superficially porous particles provide a superior kinetic performance compared to both the 3.5 and 5 μm fully porous particles over the entire relevant range of separation conditions. The performance of the superficially porous particles, however, appears to depend strongly on retention and analyte properties, emphasizing the importance of comparing different columns under realistic conditions (high enough k) and using the compound of interest. PMID:29403833
Clinical Guideline for Female Lower Urinary Tract Symptoms.
Takahashi, Satoru; Takei, Mineo; Nishizawa, Osamu; Yamaguchi, Osamu; Kato, Kumiko; Gotoh, Momokazu; Yoshimura, Yasukuni; Takeyama, Masami; Ozawa, Hideo; Shimada, Makoto; Yamanishi, Tomonori; Yoshida, Masaki; Tomoe, Hikaru; Yokoyama, Osamu; Koyama, Masayasu
2016-01-01
The "Japanese Clinical Guideline for Female Lower Urinary Tract Symptoms," published in Japan in November 2013, contains two algorithms (a primary and a specialized treatment algorithm) that are novel worldwide as they cover female lower urinary tract symptoms other than urinary incontinence. For primary treatment, necessary types of evaluation include querying the patient regarding symptoms and medical history, examining physical findings, and performing urinalysis. The types of evaluations that should be performed for select cases include evaluation with symptom/quality of life (QOL) questionnaires, urination records, residual urine measurement, urine cytology, urine culture, serum creatinine measurement, and ultrasonography. If the main symptoms are voiding/post-voiding, specialized treatment should be considered because multiple conditions may be involved. When storage difficulties are the main symptoms, the patient should be assessed using the primary algorithm. When conditions such as overactive bladder or stress incontinence are diagnosed and treatment is administered, but sufficient improvement is not achieved, the specialized algorithm should be considered. In case of specialized treatment, physiological re-evaluation, urinary tract/pelvic imaging evaluation, and urodynamic testing are conducted for conditions such as refractory overactive bladder and stress incontinence. There are two causes of voiding/post-voiding symptoms: lower urinary tract obstruction and detrusor underactivity. Lower urinary tract obstruction caused by pelvic organ prolapse may be improved by surgery. © 2015 Wiley Publishing Asia Pty Ltd.
Turbulent Flow Effects on the Biological Performance of Hydro-Turbines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richmond, Marshall C.; Romero Gomez, Pedro DJ
2014-08-25
The hydro-turbine industry uses Computational Fluid Dynamics (CFD) tools to predict the flow conditions as part of the design process for new and rehabilitated turbine units. Typically the hydraulic design process uses steady-state simulations based on Reynolds-Averaged Navier-Stokes (RANS) formulations for turbulence modeling because these methods are computationally efficient and work well to predict averaged hydraulic performance, e.g. power output, efficiency, etc. However, in view of the increasing emphasis on environmental concerns, such as fish passage, the consideration of the biological performance of hydro-turbines is also required in addition to hydraulic performance. This leads to the need to assess whethermore » more realistic simulations of the turbine hydraulic environment -those that resolve unsteady turbulent eddies not captured in steady-state RANS computations- are needed to better predict the occurrence and extent of extreme flow conditions that could be important in the evaluation of fish injury and mortality risks. In the present work, we conduct unsteady, eddy-resolving CFD simulations on a Kaplan hydro-turbine at a normal operational discharge. The goal is to quantify the impact of turbulence conditions on both the hydraulic and biological performance of the unit. In order to achieve a high resolution of the incoming turbulent flow, Detached Eddy Simulation (DES) turbulence model is used. These transient simulations are compared to RANS simulations to evaluate whether extreme hydraulic conditions are better captured with advanced eddy-resolving turbulence modeling techniques. The transient simulations of key quantities such as pressure and hydraulic shear flow that arise near the various components (e.g. wicket gates, stay vanes, runner blades) are then further analyzed to evaluate their impact on the statistics for the lowest absolute pressure (nadir pressures) and for the frequency of collisions that are known to cause mortal injury in fish passing through hydro-turbines.« less
Evaluation of an ontological resource for pharmacovigilance.
Jaulent, Marie-Christine; Alecu, Iulian
2009-01-01
In this work, we present a methodology for evaluating an ontology designed in a previous study to describe adverse drug reactions. We evaluate it in term of its fitness for grouping cases in pharmacovigilance. We define as gold standard the Standardized MedDRA Queries (SMQs) developed manually to group terms representing similar medical conditions. We perform an automatic search in the ontology in order to retrieve concepts related to the medical conditions. An optimal query is built for each medical condition. The evaluation relies on the comparison between the terms in the SMQ and the terms subsumed by the query. The result is quantified by sensitivity and specificity. We applied this methodology for 24 SMQs and we obtain a mean sensitivity of 0.82. This work allows validating the semantic resource and provides, in perspective, tools to maintain the ontology while the knowledge is evolving.
On the generalization of attitude accessibility after repeated attitude expression
Spruyt, Adriaan; Fazio, Russell H.; Hermans, Dirk
2016-01-01
Abstract The more accessible an attitude is, the stronger is its influence on information processing and behavior. Accessibility can be increased through attitude rehearsal, but it remains unknown whether attitude rehearsal also affects the accessibility of related attitudes. To investigate this hypothesis, participants in an experimental condition repeatedly expressed their attitudes towards exemplars of several semantic categories during an evaluative categorization task. Participants in a control condition performed a non‐evaluative task with the same exemplars and evaluated unrelated attitude objects. After a 30‐minute interval, participants in the experimental condition were faster than controls to evaluate not only the original exemplars but also novel exemplars of the same categories. This finding suggests that the effect of attitude rehearsal on accessibility generalizes to attitudes towards untrained but semantically related attitude objects. © 2016 The Authors. European Journal of Social Psychology published by John Wiley & Sons, Ltd. PMID:28701803
Battery testing at Argonne National Laboratory
NASA Astrophysics Data System (ADS)
Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.
1993-03-01
Argonne National Laboratory's Analysis & Diagnostic Laboratory (ADL) tests advanced batteries under simulated electric and hybrid vehicle operating conditions. The ADL facilities also include a post-test analysis laboratory to determine, in a protected atmosphere if needed, component compositional changes and failure mechanisms. The ADL provides a common basis for battery performance characterization and life evaluations with unbiased application of tests and analyses. The battery evaluations and post-test examinations help identify factors that limit system performance and life and the most-promising R&D approaches for overcoming these limitations. Since 1991, performance characterizations and/or life evaluations have been conducted on eight battery technologies: Na/S, Li/S, Zn/Br, Ni/MH, Ni/Zn, Ni/Cd, Ni/Fe, and lead-acid. These evaluations were performed for the Department of Energy's. Office of Transportation Technologies, Electric and Hybrid Propulsion Division (DOE/OTT/EHP), and Electric Power Research Institute (EPRI) Transportation Program. The results obtained are discussed.
42 CFR 482.96 - Condition of participation: Quality assessment and performance improvement (QAPI).
Code of Federal Regulations, 2013 CFR
2013-10-01
... practices, patient education, patient satisfaction, and patient rights. The transplant center must take... or arrangement. (a) Standard: Components of a QAPI program. The transplant center's QAPI program must use objective measures to evaluate the center's performance with regard to transplantation activities...
42 CFR 482.96 - Condition of participation: Quality assessment and performance improvement (QAPI).
Code of Federal Regulations, 2012 CFR
2012-10-01
... practices, patient education, patient satisfaction, and patient rights. The transplant center must take... or arrangement. (a) Standard: Components of a QAPI program. The transplant center's QAPI program must use objective measures to evaluate the center's performance with regard to transplantation activities...
42 CFR 482.96 - Condition of participation: Quality assessment and performance improvement (QAPI).
Code of Federal Regulations, 2014 CFR
2014-10-01
... practices, patient education, patient satisfaction, and patient rights. The transplant center must take... or arrangement. (a) Standard: Components of a QAPI program. The transplant center's QAPI program must use objective measures to evaluate the center's performance with regard to transplantation activities...
Do absorption and realistic distraction influence performance of component task surgical procedure?
Pluyter, Jon R; Buzink, Sonja N; Rutkowski, Anne-F; Jakimowicz, Jack J
2010-04-01
Surgeons perform complex tasks while exposed to multiple distracting sources that may increase stress in the operating room (e.g., music, conversation, and unadapted use of sophisticated technologies). This study aimed to examine whether such realistic social and technological distracting conditions may influence surgical performance. Twelve medical interns performed a laparoscopic cholecystectomy task with the Xitact LC 3.0 virtual reality simulator under distracting conditions (exposure to music, conversation, and nonoptimal handling of the laparoscope) versus nondistracting conditions (control condition) as part of a 2 x 2 within-subject experimental design. Under distracting conditions, the medical interns showed a significant decline in task performance (overall task score, task errors, and operating time) and significantly increased levels of irritation toward both the assistant handling the laparoscope in a nonoptimal way and the sources of social distraction. Furthermore, individual differences in cognitive style (i.e., cognitive absorption and need for cognition) significantly influenced the levels of irritation experienced by the medical interns. The results suggest careful evaluation of the social and technological sources of distraction in the operation room to reduce irritation for the surgeon and provision of proper preclinical laparoscope navigation training to increase security for the patient.
Future thinking instructions improve prospective memory performance in adolescents.
Altgassen, Mareike; Kretschmer, Anett; Schnitzspahn, Katharina Marlene
2017-07-01
Studies on prospective memory (PM) development in adolescents point to age-related increases through to adulthood. The goal of the present study was to examine whether instructing adolescents to engage in an episodic prospection of themselves executing future actions (i.e., future thinking) when forming an intention would improve their PM performance and reduce age-related differences. Further, we set out to explore whether future thinking instructions result in stronger memory traces and/or stronger cue-context associations by evaluating retrospective memory for the PM cues after task completion and monitoring costs during PM task processing. Adolescents and young adults were allocated to either the future thinking, repeated-encoding or standard condition. As expected, adolescents had fewer correct PM responses than young adults. Across age groups, PM performance in the standard condition was lower than in the other encoding conditions. Importantly, the results indicate a significant interaction of age by encoding condition. While adolescents benefited most from future thinking instructions, young adults performed best in the repeated-encoding condition. The results also indicate that the beneficial effects of future thinking may result from deeper intention-encoding through the simulation of future task performance.
Influence of visual observational conditions on tongue motor learning.
Kothari, Mohit; Liu, Xuemei; Baad-Hansen, Lene; Kumar, Abhishek; Bin, Guo; Svensson, Peter
2016-12-01
The aim of this study was to investigate the impact of visual observational conditions on performance during a standardized tongue-protrusion training (TPT) task and to evaluate subject-based reports of helpfulness, disturbance, pain, and fatigue, due to the observational conditions on 0-10 numerical rating scales. Forty-eight healthy participants performed a 1-h standard TPT task. Participants were randomly assigned to one of the following three groups with different observational conditions: group 1, model observation (participants watched a prerecorded video showing standard TPT before optimal TPT being performed); group 2, self-observation (participants watched live video feedback of their own TPT performance); and group 3, control group (participants performed the TPT with no conditioning). There was no overall difference between groups but TPT performance increased over time. A significant group×time interaction indicated that the self-observation group performed significantly better than the model-observation group in the last 20 min of TPT. The subject-based reports of video helpfulness showed that the model-observation group rated the prerecorded video as more helpful for TPT performance compared with the other groups but there was no significant difference between groups regarding the level of disturbance, pain, or fatigue. Self-observation of tongue-training facilitated behavioral aspects of tongue motor learning compared with model observation but not compared with control. © 2016 Eur J Oral Sci.
Pathway Design Effects on Synthetic Vision Head-Up Displays
NASA Technical Reports Server (NTRS)
Kramer, Lynda J.; Prinzel, Lawrence J., III; Arthur, Jarvis J., III; Bailey, Randall E.
2004-01-01
NASA s Synthetic Vision Systems (SVS) project is developing technologies with practical applications that will eliminate low visibility conditions as a causal factor to civil aircraft accidents while replicating the operational benefits of clear day flight operations, regardless of the actual outside visibility condition. A major thrust of the SVS project involves the development/demonstration of affordable, certifiable display configurations that provide intuitive out-the-window terrain and obstacle information with advanced pathway guidance for transport aircraft. This experiment evaluated the influence of different tunnel and guidance concepts upon pilot situation awareness (SA), mental workload, and flight path tracking performance for Synthetic Vision display concepts using a Head-Up Display (HUD). Two tunnel formats (dynamic, minimal) were evaluated against a baseline condition (no tunnel) during simulated IMC approaches to Reno-Tahoe International airport. Two guidance cues (tadpole, follow-me aircraft) were also evaluated to assess their influence on the tunnel formats. Results indicated that the presence of a tunnel on an SVS HUD had no effect on flight path performance but that it did have significant effects on pilot SA and mental workload. The dynamic tunnel concept with the follow-me aircraft guidance symbol produced the lowest workload and provided the highest SA among the tunnel concepts evaluated.
DOT National Transportation Integrated Search
2012-03-01
This research study aims at evaluating the performance of base and subgrade soil in flexible pavements under repeated loading test conditions. For this purpose, an indoor cyclic plate load testing equipment was developed and used to conduct a series ...
Test of a Cardiology Patient Simulator with Students in Fourth-Year Electives.
ERIC Educational Resources Information Center
Ewy, Gordon A.; And Others
1987-01-01
Students at five medical schools participated in an evaluation of a cardiology patient simulator (CPS), a life-size mannequin capable of simulating a wide variety of cardiovascular conditions. The CPS enhances learning both the knowledge and the skills necessary to perform a bedside cardiovascular evaluation. (Author/MLW)
DOT National Transportation Integrated Search
2009-10-01
The effects of modifying the configuration of three video detection (VD) systems (Iteris, Autoscope, and Peek) : are evaluated in daytime and nighttime conditions. Four types of errors were used: false, missed, stuck-on, and : dropped calls. The thre...
Pandolfi, Michelle M; Wang, Yun; Spenard, Ann; Johnson, Florence; Bonner, Alice; Ho, Shih-Yieh; Elwell, Timothy; Bakullari, Anila; Galusha, Deron; Leifheit-Limson, Erica; Lichtman, Judith H; Krumholz, Harlan M
2017-12-01
To evaluate community-specific nursing home performance with community-specific hospital 30-day readmissions for Medicare patients discharged with acute myocardial infarction, heart failure or pneumonia. Cross-sectional study using 2009-2012 hospital risk-standardised 30-day readmission data for Medicare fee-for-service patients hospitalised for all three conditions and nursing home performance data from the Centers for Medicare & Medicaid Services Five-Star Quality Rating System. Medicare-certified nursing homes and acute care hospitals. 12,542 nursing homes and 3,039 hospitals treating 30 or more Medicare fee-for-service patients for all three conditions across 2,032 hospital service areas in the United States. Community-specific hospital 30-day risk-standardised readmission rates. Community-specific nursing home performance measures: health inspection, staffing, Registered Nurses and quality performance; and an aggregated performance score. Mixed-effects models evaluated associations between nursing home performance and hospital 30-day risk-standardised readmission rates for all three conditions. The relationship between community-specific hospital risk-standardised readmission rates and community-specific overall nursing home performance was statistically significant for all three conditions. Increasing nursing home performance by one star resulted in decreases of 0.29% point (95% CI: 0.12-0.47), 0.78% point (95% CI: 0.60-0.95) and 0.46% point (95% CI: 0.33-0.59) of risk-standardised readmission rates for AMI, HF and pneumonia, respectively. Among the specific measures, higher performance in nursing home overall staffing and Registered Nurse staffing measures was statistically significantly associated with lower hospital readmission rates for all three conditions. Notable geographic variation in the community-specific nursing home performance was observed. Community-specific nursing home performance is associated with community-specific hospital 30-day readmission rates for Medicare fee-for-service patients for acute myocardial infarction, heart failure or pneumonia. Coordinated care between hospitals and nursing homes is essential to reduce readmissions. Nursing homes can improve performance and reduce readmissions by increasing registered nursing homes. Further, communities can work together to create cross-continuum care teams comprised of hospitals, nursing homes, patients and their families, and other community-based service providers to reduce unplanned readmissions. © 2017 John Wiley & Sons Ltd.
NASA Technical Reports Server (NTRS)
Bishu, Ram R.
1992-01-01
Human capabilities such as dexterity, manipulability, and tactile perception are unique and render the hand as a very versatile, effective and a multipurpose tool. This is especially true for unknown environments such as the EVA environment. In the microgravity environment interfaces, procedures, and activities are too complex, diverse, and defy advance definition. Under these conditions the hand becomes the primary means of locomotion, restraint, and material handling. Facilitation of these activities, with simultaneous protection from the cruel EVA environment are the two, often conflicting, objectives of glove design. The objectives of this study was (1) to assess the effects of EVA gloves at different pressures on human hand capabilities, (2) to devise a protocol for evaluating EVA gloves, (3) to develop force time relations for a number of EVA glove pressure combinations, and (4) to evaluate two types of launch and entry suit gloves. The objectives were achieved through three experiments. The experiments for achieving objectives 1, 2, and 3 were performed in the glove box in building 34. In experiment 1 three types of EVA gloves were tested at five pressure differentials. A number of performance measures were recorded. In experiment 2 the same gloves as in experiment 1 were evaluated in a reduced number of pressure conditions. The performance measure was endurance time. Six subjects participated in both the experiments. In experiment 3 two types of launch and entry suit gloves were evaluated using a paradigm similar to experiment 1. Currently the data is being analyzed. However for this report some summary analyses have been performed. The results indicate that a) With EVA gloves strength is reduced by nearly 50 percent, b) performance decrements increase with increasing pressure differential, c) TMG effects are not consistent across the three gloves tested, d) some interesting gender glove interactions were observed, some of which may have been due to the extent (or lack of) fit of the glove to the hand, and e) differences in performance exist between partial pressure suit glove and full pressure suit glove, especially in the unpressurized condition.
Failure mechanism characterization of platinum alloy
NASA Technical Reports Server (NTRS)
Rosen, J. M.; Mcfarlen, W. T.
1986-01-01
This article describes procedures and results of testing performed on a platinum/10-percent rhodium, thin-wall tubular product. The purpose of the testing was to develop exemplar SEM fractographs to be used to characterize failures under various environmental conditions. Conditions evaluated for the platinum alloys included high temperature, hydrogen environment, braze metal contamination, and cyclic loading.
Evaluation of two sources of Angus cattle under South Florida subtropical conditions
USDA-ARS?s Scientific Manuscript database
The objective of this study was to compare performance and aspects of adaptability attributes of cattle from a Florida Angus bloodline (local source from a mostly closed herd for over 50 yr) to cattle that are representative of modern Angus bloodlines (outside source) in U.S. subtropical conditions....
NASA Astrophysics Data System (ADS)
Sharma, Kshama; Madhu, P. K.; Agarwal, Vipin
2016-09-01
The performance of heteronuclear spin decoupling sequences in solid-state NMR severely degrades when the proton radiofrequency (RF) nutation frequencies (ν1) are close to or at multiples of magic-angle spinning (MAS) frequency (νr) that are referred to as rotary-resonance recoupling conditions (ν1 = n · νr). Recently, two schemes, namely, PISSARRO and rCWApA, have been shown to be less affected by the problem of MAS and RF interference, specifically at the n = 2 rotary-resonance recoupling condition, especially in the fast MAS regime. Here, we systematically evaluate the loss in intensity of several heteronuclear spin decoupling sequences at the n = 1, 2 conditions compared to high-power decoupling in the fast-MAS regime. We propose that in the fast-MAS regime (above 40 kHz) the entire discussion about RF and MAS interference can be avoided by using appropriate low-power decoupling sequences which give comparable performance to decoupling sequences with high-power 1H irradiation of ca.195 kHz.
Design and Implementation of a Thermal Load Reduction System in a Hyundai PHEV
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kreutzer, Cory J; Rugh, John P
Increased market penetration of electric drive vehicles (EDVs) requires overcoming a number of hurdles including limited vehicle range and the elevated cost of EDVs as compared to conventional vehicles. Climate control loads have a significant impact on range, cutting it by over 50% in both cooling and heating conditions. In order to minimize the impact of climate control on EDV range, the National Renewable Energy Laboratory has partnered with Hyundai America and key industry partners to quantify the performance of thermal load reduction technologies on a Hyundai Sonata PHEV. Technologies that impact vehicle cabin heating in cold weather conditions andmore » cabin cooling in warm weather conditions were evaluated. Tests included thermal transient and steady-state periods for all technologies, including the development of a new test methodology to evaluate the performance of occupant thermal conditioning. Heated surfaces and increased insulation demonstrated significant reductions in energy use from steady-state heating, including a 29% - 59% reduction from heated surfaces. Solar control glass packages demonstrated significant reductions in energy use for both transient and steady-state cooling, with up to a 42% reduction in transient and 12.8% reduction in steady-state energy use for the packages evaluated. Technologies that demonstrated significant climate control load reduction were selected for incorporation into a complete thermal load reduction package. The complete package is set to be evaluated in the second phase of the ongoing project.« less
Impact of 5-h phase advance on sleep architecture and physical performance in athletes.
Petit, Elisabeth; Mougin, Fabienne; Bourdin, Hubert; Tio, Grégory; Haffen, Emmanuel
2014-11-01
Travel across time zones causes jet lag and is accompanied by deleterious effects on sleep and performance in athletes. These poor performances have been evaluated in field studies but not in laboratory conditions. The purpose of this study was to evaluate, in athletes, the impact of 5-h phase advance on the architecture of sleep and physical performances (Wingate test). In a sleep laboratory, 16 male athletes (age: 22.2 ± 1.7 years, height: 178.3 ± 5.6 cm, body mass: 73.6 ± 7.9 kg) spent 1 night in baseline condition and 2 nights, 1 week apart, in phase shift condition recorded by electroencephalography to calculate sleep architecture variables. For these last 2 nights, the clock was advanced by 5 h. Core body temperature rhythm was assessed continuously. The first night with phase advance decreased total sleep time, sleep efficiency, sleep onset latency, stage 2 of nonrapid eye movement (N2), and rapid eye movement (REM) sleep compared with baseline condition, whereas the second night decreased N2 and increased slow-wave sleep and REM, thus improving the quality of sleep. After phase advance, mean power improved, which resulted in higher lactatemia. Acrophase and bathyphase of temperature occurred earlier and amplitude decreased in phase advance but the period was not modified. These results suggest that a simulated phase shift contributed to the changes in sleep architecture, but did not significantly impair physical performances in relation with early phase adjustment of temperature to the new local time.
Internal Performance Evaluation of a Two Position Divergent Shroud Ejector
NASA Technical Reports Server (NTRS)
Mihaloew, James R.; Stofan, Andrew J.
1960-01-01
A two-position divergent shroud ejector was investigated in an unheated quiescent-air facility over a range of operational variables applicable to a Mach 2.5 aircraft. The performance data are shown in terms of hypothetical engine operating conditions to illustrate variations of performance with Mach number. The overall thrust performance was reasonably good, with ejector thrust ratios ranging from 0.97 to 0.98 for all conditions except that corresponding to acceleration with afterburning through the transonic flight Mach number region from 0.9 to 1.1, where the ejector thrust ratio decreased to as low as 0.945 for an ejector corrected weight-flow ratio of 0.105.
Short-Term Effects of Rolling Massage on Energy Cost of Running and Power of the Lower Limbs.
Giovanelli, Nicola; Vaccari, Filippo; Floreani, Mirco; Rejc, Enrico; Copetti, Jasmine; Garra, Marco; Biasutti, Lea; Lazzer, Stefano
2018-05-10
Self-myofascial release (SMFR) is a type of self-massage that is becoming popular among athletes. However, SMFR effects on running performance have not been investigated yet. The aim of the present study was to evaluate the effects of SMFR on cost of running (Cr). In addition, we evaluated the effects of SMFR on lower limbs muscle power. The measurement of Cr and lower limb muscle power during squat jump (SJ) and counter movement jump (CMJ) were performed before (PRE), immediately after (POST) and 3hours after (POST 3h) a SMFR protocol (experimental condition). In the "control condition" testing session, the same measurements were performed without undergoing the SMFR protocol. Experimental and control conditions were tested in a randomized order. Cr at POST trended to increase as compared to PRE (+6.2±8.3%, p=0.052), while at POST 3h Cr was restored to PRE values (+0.28±9.5%, p=0.950). In the experimental condition, no significant "Time" effect was observed for maximal power exerted during SJ. On the other hand, maximal power exerted during CMJ at POST and POST 3h was significantly higher than that observed at PRE (+7.9±6.3%, p=0.002; and +10.0±8.7%, p=0.004, respectively). The rate of force development measured during CMJ also increased after SMFR, reaching statistical significance at 200 ms from force onset at POST 3h (+38.9%, p=0.024). an acute use of foam roller for SMFR performed immediately prior to running may negatively affect the endurance running performance, while its use should be added before explosive motor performances that include stretch-shortening cycles.
A normal incidence X-ray telescope
NASA Technical Reports Server (NTRS)
Golub, Leon
1987-01-01
The postflight performance evaluation of the X-ray telescope was summarized. All payload systems and subsystems performed well within acceptable limits, with the sole exception of the light-blocking prefilters. Launch, flight and recovery were performed in a fully satisfactory manner. The payload was recovered in a timely manner and in excellent condition. The prefilter performance analysis showed that no X-ray images were detected on the processed flight film. Recommendations for improved performance are listed.
Chen, Junwen; McLean, Jordan E; Kemps, Eva
2018-03-01
This study investigated the effects of combined audience feedback with video feedback plus cognitive preparation, and cognitive review (enabling deeper processing of feedback) on state anxiety and self-perceptions including perception of performance and perceived probability of negative evaluation in socially anxious individuals during a speech performance. One hundred and forty socially anxious students were randomly assigned to four conditions: Cognitive Preparation + Video Feedback + Audience Feedback + Cognitive Review (CP+VF+AF+CR), Cognitive Preparation + Video Feedback + Cognitive Review (CP+VF+CR), Cognitive Preparation + Video Feedback only (CP+VF), and Control. They were asked to deliver two impromptu speeches that were evaluated by confederates. Participants' levels of anxiety and self-perceptions pertaining to the speech task were assessed before and after feedback, and after the second speech. Compared to participants in the other conditions, participants in the CP+VF+AF+CR condition reported a significant decrease in their state anxiety and perceived probability of negative evaluation scores, and a significant increase in their positive perception of speech performance from before to after the feedback. These effects generalized to the second speech. Our results suggest that adding audience feedback to video feedback plus cognitive preparation and cognitive review may improve the effects of existing video feedback procedures in reducing anxiety symptoms and distorted self-representations in socially anxious individuals. Copyright © 2017. Published by Elsevier Ltd.
In vitro evaluation of the Medtronic cardioplegia safety system.
Trowbridge, C C; Woods, K R; Muhle, M L; Niimi, K S; Tremain, K D; Jiang, J; Stammers, A H
2000-03-01
Myocardial preservation demands the precise and accurate delivery of cardioplegic solutions to provide nutritive delivery and metabolic waste removal. The purpose of this study was to evaluate the performance characteristics of the Medtronic CSS Cardioplegia Safety System in an in vitro setting. The CSS was evaluated under the following conditions: blood to crystalloid ratios of 1:0, 1:1, 4:1, 8:1, 0:1; potassium concentrations of 10, 20, and 40 mEq L-1; volumetric delivery collection at 100, 250, 500, 750, and 990 mL/min; pressure accuracy at 100 and 300 mmHg; and system safety mechanisms. Measured and predicted values from the CSS were compared using one way ANOVA, with statistical significance accepted at p < or = 0.05. The measured values for the tested ratios and volume collections were all within the manufacturer's technical parameters. Potassium concentration results were all within expected values except at 100 mL/min, where the measured value of 17.1 +/- 2.1 mmol was lower than the expected 20.0 +/- 0.2 mmol (p < .034). As flow rates changed, the CSS line pressure error was constant (0.5 to 3.7%), and the only significant difference was observed at 100 mmHg, 500 mL/min (102.3 +/- 1.7 vs. 100.0 +/- 0.0 mmHg, P < .003). The device performed accurately and reliably under all simulated safety conditions, including bubble detection, over pressurization and battery backup. In conclusion, the performance of the CSS was within the manufacturer's specifications for the majority of the tested conditions and operated safely when challenged under varying conditions.
NDT evaluation of long-term bond durability of CFRP-structural systems applied to RC highway bridges
NASA Astrophysics Data System (ADS)
Crawford, Kenneth C.
2016-06-01
The long-term durability of CFRP structural systems applied to reinforced-concrete (RC) highway bridges is a function of the system bond behavior over time. The sustained structural load performance of strengthened bridges depends on the carbon fiber-reinforced polymer (CFRP) laminates remaining 100 % bonded to concrete bridge members. Periodic testing of the CFRP-concrete bond condition is necessary to sustain load performance. The objective of this paper is to present a non-destructive testing (NDT) method designed to evaluate the bond condition and long-term durability of CFRP laminate (plate) systems applied to RC highway bridges. Using the impact-echo principle, a mobile mechanical device using light impact hammers moving along the length of a bonded CFRP plate produces unique acoustic frequencies which are a function of existing CFRP plate-concrete bond conditions. The purpose of this method is to test and locate CFRP plates de-bonded from bridge structural members to identify associated deterioration in bridge load performance. Laboratory tests of this NDT device on a CFRP plate bonded to concrete with staged voids (de-laminations) produced different frequencies for bonded and de-bonded areas of the plate. The spectra (bands) of frequencies obtained in these tests show a correlation to the CFRP-concrete bond condition and identify bonded and de-bonded areas of the plate. The results of these tests indicate that this NDT impact machine, with design improvements, can potentially provide bridge engineers a means to rapidly evaluate long lengths of CFRP laminates applied to multiple highway bridges within a national transportation infrastructure.
Symonowicz, Marzena; Sykuła-Zajac, Anna; Łodyga-Chruścińska, Elzbieta; Rumora, Ivana; Straukas, Martinas
2012-01-01
An evaluation of total polyphenols and anthocyanins contents in dietary supplements is important analysis in medical aspect of human and animal diets. The content of the mentioned compounds should be higher in 100 g of solid extracts than in 100 g of fruits. Thus, the presented work concerns the evaluation of total polyphenols and anthocyanins contents in black chockeberry--Photinia melanocarpa (Michx.) extract--dietary supplement (DS) available on market. The spectrophotometric analysis of DS were performed. The usage of certain conditions of measurements such as dilution factor, storage conditions and filtration, has the significance in the determination of the analyzed compounds in the extract.
High-power UV-LED degradation: Continuous and cycled working condition influence
NASA Astrophysics Data System (ADS)
Arques-Orobon, F. J.; Nuñez, N.; Vazquez, M.; Segura-Antunez, C.; González-Posadas, V.
2015-09-01
High-power (HP) UV-LEDs can replace UV lamps for real-time fluoro-sensing applications by allowing portable and autonomous systems. However, HP UV-LEDs are not a mature technology, and there are still open issues regarding their performance evolution over time. This paper presents a reliability study of 3 W UV-LEDs, with special focus on LED degradation for two working conditions: continuous and cycled (30 s ON and 30 s OFF). Accelerated life tests are developed to evaluate the influence of temperature and electrical working conditions in high-power LEDs degradation, being the predominant failure mechanism the degradation of the package. An analysis that includes dynamic thermal and optical HP UV-LED measurements has been performed. Static thermal and stress simulation analysis with the finite element method (FEM) identifies the causes of package degradation. Accelerated life test results prove that HP UV-LEDs working in cycled condition have a better performance than those working in continuous condition.
NASA Technical Reports Server (NTRS)
Campbell, Stefan F.; Kaneshige, John T.; Nguyen, Nhan T.; Krishakumar, Kalmanje S.
2010-01-01
Presented here is the evaluation of multiple adaptive control technologies for a generic transport aircraft simulation. For this study, seven model reference adaptive control (MRAC) based technologies were considered. Each technology was integrated into an identical dynamic-inversion control architecture and tuned using a methodology based on metrics and specific design requirements. Simulation tests were then performed to evaluate each technology s sensitivity to time-delay, flight condition, model uncertainty, and artificially induced cross-coupling. The resulting robustness and performance characteristics were used to identify potential strengths, weaknesses, and integration challenges of the individual adaptive control technologies
Roverud, Elin; Best, Virginia; Mason, Christine R; Streeter, Timothy; Kidd, Gerald
2017-12-15
The "visually guided hearing aid" (VGHA), consisting of a beamforming microphone array steered by eye gaze, is an experimental device being tested for effectiveness in laboratory settings. Previous studies have found that beamforming without visual steering can provide significant benefits (relative to natural binaural listening) for speech identification in spatialized speech or noise maskers when sound sources are fixed in location. The aim of the present study was to evaluate the performance of the VGHA in listening conditions in which target speech could switch locations unpredictably, requiring visual steering of the beamforming. To address this aim, the present study tested an experimental simulation of the VGHA in a newly designed dynamic auditory-visual word congruence task. Ten young normal-hearing (NH) and 11 young hearing-impaired (HI) adults participated. On each trial, three simultaneous spoken words were presented from three source positions (-30, 0, and 30 azimuth). An auditory-visual word congruence task was used in which participants indicated whether there was a match between the word printed on a screen at a location corresponding to the target source and the spoken target word presented acoustically from that location. Performance was compared for a natural binaural condition (stimuli presented using impulse responses measured on KEMAR), a simulated VGHA condition (BEAM), and a hybrid condition that combined lowpass-filtered KEMAR and highpass-filtered BEAM information (BEAMAR). In some blocks, the target remained fixed at one location across trials, and in other blocks, the target could transition in location between one trial and the next with a fixed but low probability. Large individual variability in performance was observed. There were significant benefits for the hybrid BEAMAR condition relative to the KEMAR condition on average for both NH and HI groups when the targets were fixed. Although not apparent in the averaged data, some individuals showed BEAM benefits relative to KEMAR. Under dynamic conditions, BEAM and BEAMAR performance dropped significantly immediately following a target location transition. However, performance recovered by the second word in the sequence and was sustained until the next transition. When performance was assessed using an auditory-visual word congruence task, the benefits of beamforming reported previously were generally preserved under dynamic conditions in which the target source could move unpredictably from one location to another (i.e., performance recovered rapidly following source transitions) while the observer steered the beamforming via eye gaze, for both young NH and young HI groups.
WRF/CMAQ AQMEII3 Simulations of U.S. Regional-Scale Ozone: Sensitivity to Processes and Inputs
Chemical boundary conditions are a key input to regional-scale photochemical models. In this study, performed during the third phase of the Air Quality Model Evaluation International Initiative (AQMEII3), we perform annual simulations over North America with chemical boundary con...
A pilot scale electrical infrared dry-peeling system for tomatoes: design and performance evaluation
USDA-ARS?s Scientific Manuscript database
A pilot scale infrared dry-peeling system for tomatoes was designed and constructed. The system consisted of three major sections including the IR heating, vacuum, and pinch roller sections. The peeling performance of the system was examined under different operational conditions using tomatoes with...
Performance, Cognition, and Physiological Responding in Test Anxiety.
ERIC Educational Resources Information Center
Holroyd, Kenneth A.; And Others
1978-01-01
This research was designed to clarify the role of autonomic response and evaluative self-awareness in test anxiety. Autonomic, self-report, and performance measures of anxiety were collected from both test-anxious and non-test-anxious individuals in an analogue testing situation under three experimental conditions. Results support cognitive…
DOT National Transportation Integrated Search
1999-04-01
Sixteen high performance concrete overlays were placed on two 28-span bridges on Rte. 60 over Lynnhaven Inlet, Virginia Beach, : Virginia, in the spring of 1996. The construction was funded with 20 percent Virginia Department of Transportation mainte...
NASA Astrophysics Data System (ADS)
Miwa, Shotaro; Kage, Hiroshi; Hirai, Takashi; Sumi, Kazuhiko
We propose a probabilistic face recognition algorithm for Access Control System(ACS)s. Comparing with existing ACSs using low cost IC-cards, face recognition has advantages in usability and security that it doesn't require people to hold cards over scanners and doesn't accept imposters with authorized cards. Therefore face recognition attracts more interests in security markets than IC-cards. But in security markets where low cost ACSs exist, price competition is important, and there is a limitation on the quality of available cameras and image control. Therefore ACSs using face recognition are required to handle much lower quality images, such as defocused and poor gain-controlled images than high security systems, such as immigration control. To tackle with such image quality problems we developed a face recognition algorithm based on a probabilistic model which combines a variety of image-difference features trained by Real AdaBoost with their prior probability distributions. It enables to evaluate and utilize only reliable features among trained ones during each authentication, and achieve high recognition performance rates. The field evaluation using a pseudo Access Control System installed in our office shows that the proposed system achieves a constant high recognition performance rate independent on face image qualities, that is about four times lower EER (Equal Error Rate) under a variety of image conditions than one without any prior probability distributions. On the other hand using image difference features without any prior probabilities are sensitive to image qualities. We also evaluated PCA, and it has worse, but constant performance rates because of its general optimization on overall data. Comparing with PCA, Real AdaBoost without any prior distribution performs twice better under good image conditions, but degrades to a performance as good as PCA under poor image conditions.
NASA Technical Reports Server (NTRS)
Saus, Joseph R.; DeLaat, John C.; Chang, Clarence T.; Vrnak, Daniel R.
2012-01-01
At the NASA Glenn Research Center, a characterization rig was designed and constructed for the purpose of evaluating high bandwidth liquid fuel modulation devices to determine their suitability for active combustion control research. Incorporated into the rig s design are features that approximate conditions similar to those that would be encountered by a candidate device if it were installed on an actual combustion research rig. The characterized dynamic performance measures obtained through testing in the rig are planned to be accurate indicators of expected performance in an actual combustion testing environment. To evaluate how well the characterization rig predicts fuel modulator dynamic performance, characterization rig data was compared with performance data for a fuel modulator candidate when the candidate was in operation during combustion testing. Specifically, the nominal and off-nominal performance data for a magnetostrictive-actuated proportional fuel modulation valve is described. Valve performance data were collected with the characterization rig configured to emulate two different combustion rig fuel feed systems. Fuel mass flows and pressures, fuel feed line lengths, and fuel injector orifice size was approximated in the characterization rig. Valve performance data were also collected with the valve modulating the fuel into the two combustor rigs. Comparison of the predicted and actual valve performance data show that when the valve is operated near its design condition the characterization rig can appropriately predict the installed performance of the valve. Improvements to the characterization rig and accompanying modeling activities are underway to more accurately predict performance, especially for the devices under development to modulate fuel into the much smaller fuel injectors anticipated in future lean-burning low-emissions aircraft engine combustors.
Design concerns of room and pillar retreat panels
Klemetti, Ted M.; Sears, Morgan M.; Tulu, Ihsan B.
2017-01-01
Why do some room and pillar retreat panels encounter abnormal conditions? What factors deserve the most consideration during the planning and execution phases of mining and what can be done to mitigate those abnormal conditions when they are encountered? To help answer these questions, and to determine some of the relevant factors influencing the conditions of room and pillar (R & P) retreat mining entries, four consecutive R & P retreat panels were evaluated. This evaluation was intended to reinforce the influence of topographic changes, depth of cover, multiple-seam interactions, geological conditions, and mining geometry. This paper details observations were made in four consecutive R & P retreat panels and the data were collected from an instrumentation site during retreat mining. The primary focus was on the differences observed among the four panels and within the panels themselves. The instrumentation study was initially planned to evaluate the interactions between primary and secondary support, but produced rather interesting results relating to the loading encountered under the current mining conditions. In addition to the observation and instrumentation, numerical modeling was performed to evaluate the stress conditions. Both the LaModel 3.0 and Rocscience Phase 2 programs were used to evaluate these four panels. The results of both models indicated a drastic reduction in the vertical stresses experienced in these panels due to the full extraction mining in overlying seams when compared to the full overburden load. Both models showed a higher level of stress associated with the outside entries of the panels. These results agree quite well with the observations and instrumentation studies performed at the mine. These efforts provided two overarching conclusions concerning R & P retreat mine planning and execution. The first was that there are four areas that should not be overlooked during R & P retreat mining: topographic relief, multiple-seam stress relief, stress concentrations near the gob edge, and geologic changes in the immediate roof. The second is that in order to successfully retreat an R & P panel, a three-phased approach to the design and analysis of the panel should be conducted: the planning phase, evaluation phase, and monitoring phase. PMID:28626598
The effects of spatially displaced visual feedback on remote manipulator performance
NASA Technical Reports Server (NTRS)
Smith, Randy L.; Stuart, Mark A.
1993-01-01
The results of this evaluation have important implications for the arrangement of remote manipulation worksites and the design of workstations for telerobot operations. This study clearly illustrates the deleterious effects that can accompany the performance of remote manipulator tasks when viewing conditions are less than optimal. Future evaluations should emphasize telerobot camera locations and the use of image/graphical enhancement techniques in an attempt to lessen the adverse effects of displaced visual feedback. An important finding in this evaluation is the extent to which results from previously performed direct manipulation studies can be generalized to remote manipulation studies. Even though the results obtained were very similar to those of the direct manipulation evaluations, there were differences as well. This evaluation has demonstrated that generalizations to remote manipulation applications based upon the results of direct manipulation studies are quite useful, but they should be made cautiously.
Stroop performance, dissociation, and trauma exposure in a community sample of children.
DePrince, Anne P; Weinzierl, Kristin M; Combs, Melody D
2008-01-01
Extending previous research with adults, the current study examined Stroop task performance under selective and divided attention demands in a community sample of school-age children (N = 97). Stroop interference scores in both attention conditions were calculated. Higher levels of child-reported dissociation were associated with better interference control under divided attention conditions and worse control under selective attention conditions; lower levels of dissociation were associated with the opposite pattern. Both family violence exposure and Stroop interaction scores explained unique variance in dissociation scores. Although research with adults has generally assumed or implied that cognitive correlates of dissociation are a consequence of dissociation, the current findings with school-age children suggest that future research should evaluate executive function performance (in this case, interference control) as a possible risk factor for dissociation.
An Evaluation of a Combat Conditioning Trial Program
2008-11-20
rests on the weaker assumption that the pretest is correlated with the posttest score. The second reason was that ANCOVA would yield training effects...performance. cSignificant Unit x Time interaction in ANCOVA. Note. Pretest performance was a significant (p < .001) predictor of posttest performance for... Pretest fitness level was defined by splitting the pretest distribution for CV into quartiles. Posttest performance improved 7.2% for participants in
Implementation of the qualities of radiodiagnostic: mammography
NASA Astrophysics Data System (ADS)
Pacífico, L. C.; Magalhães, L. A. G.; Peixoto, J. G. P.; Fernandes, E.
2018-03-01
The objective of the present study was to evaluate the expanded uncertainty of the mammographic calibration process and present the result of the internal audit performed at the Laboratory of Radiological Sciences (LCR). The qualities of the mammographic beans that are references in the LCR, comprises two irradiation conditions: no-attenuated beam and attenuated beam. Both had satisfactory results, with an expanded uncertainty equals 2,1%. The internal audit was performed, and the degree of accordance with the ISO/IEC 17025 was evaluated. The result of the internal audit was satisfactory. We conclude that LCR can perform calibrations on mammography qualities for end users.
Kim, Youngseop; Choi, Eun Seo; Kwak, Wooseop; Shin, Yongjin; Jung, Woonggyu; Ahn, Yeh-Chan; Chen, Zhongping
2008-06-01
We demonstrate the use of optical coherence tomography (OCT) as a non-destructive diagnostic tool for evaluating laser-processing performance by imaging the features of a pit and a rim. A pit formed on a material at different laser-processing conditions is imaged using both a conventional scanning electron microscope (SEM) and OCT. Then using corresponding images, the geometrical characteristics of the pit are analyzed and compared. From the results, we could verify the feasibility and the potential of the application of OCT to the monitoring of the laser-processing performance.
Vehicle test report: Jet Industries Electra Van 600
NASA Technical Reports Server (NTRS)
Price, T. W.; Wirth, V. A., Jr.
1982-01-01
The Electra Van 600, an electric vehicle, was tested. Tests were performed to characterize parameters of the Electra Van 600 and to provide baseline data to be used for comparison of improved batteries and to which will be incorporated into the vehicle. The vehicle tests concentrated on the electrical drive subsystem, the batteries, controller, and motor; coastdowns to characterize the road load and range evaluation for cyclic and constant speed conditions; and qualitative performance was evaluated. It is found that the Electra Van 600 range performance is approximately equal to the majority of the vehicles tested previously.
Kim, Youngseop; Choi, Eun Seo; Kwak, Wooseop; Shin, Yongjin; Jung, Woonggyu; Ahn, Yeh-Chan; Chen, Zhongping
2014-01-01
We demonstrate the use of optical coherence tomography (OCT) as a non-destructive diagnostic tool for evaluating laser-processing performance by imaging the features of a pit and a rim. A pit formed on a material at different laser-processing conditions is imaged using both a conventional scanning electron microscope (SEM) and OCT. Then using corresponding images, the geometrical characteristics of the pit are analyzed and compared. From the results, we could verify the feasibility and the potential of the application of OCT to the monitoring of the laser-processing performance. PMID:24932051
Evaluating brain-computer interface performance using color in the P300 checkerboard speller.
Ryan, D B; Townsend, G; Gates, N A; Colwell, K; Sellers, E W
2017-10-01
Current Brain-Computer Interface (BCI) systems typically flash an array of items from grey to white (GW). The objective of this study was to evaluate BCI performance using uniquely colored stimuli. In addition to the GW stimuli, the current study tested two types of color stimuli (grey to color [GC] and color intensification [CI]). The main hypotheses were that in a checkboard paradigm, unique color stimuli will: (1) increase BCI performance over the standard GW paradigm; (2) elicit larger event-related potentials (ERPs); and, (3) improve offline performance with an electrode selection algorithm (i.e., Jumpwise). Online results (n=36) showed that GC provides higher accuracy and information transfer rate than the CI and GW conditions. Waveform analysis showed that GC produced higher amplitude ERPs than CI and GW. Information transfer rate was improved by the Jumpwise-selected channel locations in all conditions. Unique color stimuli (GC) improved BCI performance and enhanced ERPs. Jumpwise-selected electrode locations improved offline performance. These results show that in a checkerboard paradigm, unique color stimuli increase BCI performance, are preferred by participants, and are important to the design of end-user applications; thus, could lead to an increase in end-user performance and acceptance of BCI technology. Copyright © 2017 International Federation of Clinical Neurophysiology. All rights reserved.
The effects of partial sleep restriction and altered sleep timing on olfactory performance.
McNeil, J; Forest, G; Hintze, L J; Brunet, J-F; Doucet, É
2017-12-01
Olfaction can increase the drive to eat and may partially explain the consistent increases in energy intake (EI) following sleep restriction. We investigated the effects of 50% sleep restriction with altered sleep timing on olfactory performance. We also evaluated whether changes (Δ) in olfactory performance were associated with Δ24 h EI. Twelve men and six women (age: 23±4 years; BMI: 23±3 kg/m 2 ) completed three randomized cross-over conditions: habitual sleep duration, 50% sleep restriction with advanced wake-time, and 50% sleep restriction with delayed bedtime. Sleep was measured in-laboratory (polysomnography). Olfactory performance ('sniffin sticks') and 24 h EI (food menu) were evaluated the next day. A trend for a significant condition*sex interaction was noted for threshold-discrimination-identification (TDI) scores (P=0.09); TDI scores were lowest in women and highest in men, following sleep restriction with advanced wake-time. Δolfactory performance were not associated with Δ24 h EI. The impact of sleep restriction on olfactory performance may differ between sexes. Changes in olfactory performance were not associated with changes in 24 h EI. Studies investigating prolonged effects of sleep loss on the relationship between olfactory performance with EI are needed.
Liu, Boquan; Polce, Evan; Sprott, Julien C; Jiang, Jack J
2018-05-17
The purpose of this study is to introduce a chaos level test to evaluate linear and nonlinear voice type classification method performances under varying signal chaos conditions without subjective impression. Voice signals were constructed with differing degrees of noise to model signal chaos. Within each noise power, 100 Monte Carlo experiments were applied to analyze the output of jitter, shimmer, correlation dimension, and spectrum convergence ratio. The computational output of the 4 classifiers was then plotted against signal chaos level to investigate the performance of these acoustic analysis methods under varying degrees of signal chaos. A diffusive behavior detection-based chaos level test was used to investigate the performances of different voice classification methods. Voice signals were constructed by varying the signal-to-noise ratio to establish differing signal chaos conditions. Chaos level increased sigmoidally with increasing noise power. Jitter and shimmer performed optimally when the chaos level was less than or equal to 0.01, whereas correlation dimension was capable of analyzing signals with chaos levels of less than or equal to 0.0179. Spectrum convergence ratio demonstrated proficiency in analyzing voice signals with all chaos levels investigated in this study. The results of this study corroborate the performance relationships observed in previous studies and, therefore, demonstrate the validity of the validation test method. The presented chaos level validation test could be broadly utilized to evaluate acoustic analysis methods and establish the most appropriate methodology for objective voice analysis in clinical practice.
Effect of Cognitive Demand on Functional Visual Field Performance in Senior Drivers with Glaucoma.
Gangeddula, Viswa; Ranchet, Maud; Akinwuntan, Abiodun E; Bollinger, Kathryn; Devos, Hannes
2017-01-01
Purpose: To investigate the effect of cognitive demand on functional visual field performance in drivers with glaucoma. Method: This study included 20 drivers with open-angle glaucoma and 13 age- and sex-matched controls. Visual field performance was evaluated under different degrees of cognitive demand: a static visual field condition (C1), dynamic visual field condition (C2), and dynamic visual field condition with active driving (C3) using an interactive, desktop driving simulator. The number of correct responses (accuracy) and response times on the visual field task were compared between groups and between conditions using Kruskal-Wallis tests. General linear models were employed to compare cognitive workload, recorded in real-time through pupillometry, between groups and conditions. Results: Adding cognitive demand (C2 and C3) to the static visual field test (C1) adversely affected accuracy and response times, in both groups ( p < 0.05). However, drivers with glaucoma performed worse than did control drivers when the static condition changed to a dynamic condition [C2 vs. C1 accuracy; glaucoma: median difference (Q1-Q3) 3 (2-6.50) vs. 2 (0.50-2.50); p = 0.05] and to a dynamic condition with active driving [C3 vs. C1 accuracy; glaucoma: 2 (2-6) vs. 1 (0.50-2); p = 0.02]. Overall, drivers with glaucoma exhibited greater cognitive workload than controls ( p = 0.02). Conclusion: Cognitive demand disproportionately affects functional visual field performance in drivers with glaucoma. Our results may inform the development of a performance-based visual field test for drivers with glaucoma.
Studies on the exercise physiology of draft horses performed in Japan during the 1950s and 1960s.
Hiraga, Atsushi; Sugano, Shigeru
2017-01-01
Although the total number of horses raised in Japan dramatically decreased after World War II, because draft horses were still used for farm work in paddy fields and on farms during the period of the 1950s and 1960s, a performance test for selecting better draft horses was needed. In order to determine the most suitable size of draft horses for Japanese farm conditions, the working power of horses weighing from 185 to 622 kg was evaluated by performing an endurance test, several kinds of working power tests, and maximum pulling power tests. Oxygen consumption during draft exercise was measured by the Douglas bag method in order to evaluate effects of draft workload under the conditions of different types of work (14- and 18-cm plow depths, cultivator, and tillage), traction methods (shoulder traction, shoulder-trunk traction, and chest-trunk traction), walking speeds (40, 60, 80, 100, and 120 m/min), and depths of water (0, 18, 36, and 54 cm) on energy expenditure. The relationship between energy consumption and pulse rate during exercise was also evaluated. A study of a performance test for draft horses was conducted to establish a new approach for evaluating draft horse performance using heart rate as an index. For this study, a beat meter for measuring heart rate was developed, and experimental protocols were used to evaluate the relationship between heart rate and workload. Although the research results obtained from these studies do not have particular relevance in the current day, these studies are valuable for understanding the history of equine exercise physiology in Japan.
Studies on the exercise physiology of draft horses performed in Japan during the 1950s and 1960s
HIRAGA, Atsushi; SUGANO, Shigeru
2017-01-01
ABSTRACT Although the total number of horses raised in Japan dramatically decreased after World War II, because draft horses were still used for farm work in paddy fields and on farms during the period of the 1950s and 1960s, a performance test for selecting better draft horses was needed. In order to determine the most suitable size of draft horses for Japanese farm conditions, the working power of horses weighing from 185 to 622 kg was evaluated by performing an endurance test, several kinds of working power tests, and maximum pulling power tests. Oxygen consumption during draft exercise was measured by the Douglas bag method in order to evaluate effects of draft workload under the conditions of different types of work (14- and 18-cm plow depths, cultivator, and tillage), traction methods (shoulder traction, shoulder-trunk traction, and chest-trunk traction), walking speeds (40, 60, 80, 100, and 120 m/min), and depths of water (0, 18, 36, and 54 cm) on energy expenditure. The relationship between energy consumption and pulse rate during exercise was also evaluated. A study of a performance test for draft horses was conducted to establish a new approach for evaluating draft horse performance using heart rate as an index. For this study, a beat meter for measuring heart rate was developed, and experimental protocols were used to evaluate the relationship between heart rate and workload. Although the research results obtained from these studies do not have particular relevance in the current day, these studies are valuable for understanding the history of equine exercise physiology in Japan. PMID:28400701
... Test is Performed The test is used to evaluate respiratory diseases and conditions that affect the lungs. ... may include: Bleeding at the puncture site Blood flow problems at puncture site (rare) Bruising at the ...
El-Wakeel, Amr S; Mohammed, Nazmi A; Aly, Moustafa H
2016-09-10
In this work, a free space optical communication (FSO) link is proposed and utilized to explore and evaluate the FSO link performance under the joint occurrence of the atmospheric scattering and turbulence phenomena for 850 and 1550 nm operation. Diffraction and nondiffraction-limited systems are presented and evaluated for both wavelengths' operation, considering far-field conditions under different link distances. Bit error rate, pointing error angles, beam divergence angles, and link distance are the main performance indicators that are used to evaluate and compare the link performance under different system configurations and atmospheric phenomena combinations. A detailed study is performed to provide the merits of this work. For both far-field diffraction-limited and nondiffraction-limited systems, it is concluded that 1550 nm system operation is better than 850 nm for the whole presented joint occurrences of atmospheric scattering and turbulence.
Lithographic performance comparison with various RET for 45-nm node with hyper NA
NASA Astrophysics Data System (ADS)
Adachi, Takashi; Inazuki, Yuichi; Sutou, Takanori; Kitahata, Yasuhisa; Morikawa, Yasutaka; Toyama, Nobuhito; Mohri, Hiroshi; Hayashi, Naoya
2006-05-01
In order to realize 45 nm node lithography, strong resolution enhancement technology (RET) and water immersion will be needed. In this research, we discussed about various RET performance comparison for 45 nm node using 3D rigorous simulation. As a candidate, we chose binary mask (BIN), several kinds of attenuated phase-shifting mask (att-PSM) and chrome-less phase-shifting lithography mask (CPL). The printing performance was evaluated and compared for each RET options, after the optimizing illumination conditions, mask structure and optical proximity correction (OPC). The evaluation items of printing performance were CD-DOF, contrast-DOF, conventional ED-window and MEEF, etc. It's expected that effect of mask 3D topography becomes important at 45 nm node, so we argued about not only the case of ideal structures, but also the mask topography error effects. Several kinds of mask topography error were evaluated and we confirmed how these errors affect to printing performance.
Effect of variable tinted spectacle lenses on visual performance in control subjects.
Lee, Jason E; Stein, Jonathan J; Prevor, Meredith B; Seiple, William H; Holopigian, Karen; Greenstein, Vivienne C; Stenson, Susan M
2002-04-01
To evaluate quantitatively the effects of tinted spectacle lenses on visual performance in individuals without visual pathology. Twenty-five subjects were assessed by measuring contrast sensitivity with and without glare. Gray, brown, yellow, green, purple, and blue lens tints were evaluated. Measurements were repeated with each lens tint and with a clear lens, and the order was counterbalanced within and between subjects. Glare was induced with a modified brightness acuity tester. All subjects demonstrated an increase in contrast thresholds under glare conditions for all lens tints. However, purple and blue lens tints resulted in the least amount of contrast threshold increase; the yellow lens tint resulted in the largest contrast threshold increase. Purple and blue lens tints may improve contrast sensitivity in control subjects under glare conditions.
2013-03-01
5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES...meet conditions on the ground, according to U.S. officials. For example , the Department of State (State) delayed committing Foreign Military...agencies measure program performance. For example , GAO found in 2011 that the IMET program evaluation efforts had few of the elements commonly
Pillai, Roshni; Yathiraj, Asha
2017-09-01
The study evaluated whether there exists a difference/relation in the way four different memory skills (memory score, sequencing score, memory span, & sequencing span) are processed through the auditory modality, visual modality and combined modalities. Four memory skills were evaluated on 30 typically developing children aged 7 years and 8 years across three modality conditions (auditory, visual, & auditory-visual). Analogous auditory and visual stimuli were presented to evaluate the three modality conditions across the two age groups. The children obtained significantly higher memory scores through the auditory modality compared to the visual modality. Likewise, their memory scores were significantly higher through the auditory-visual modality condition than through the visual modality. However, no effect of modality was observed on the sequencing scores as well as for the memory and the sequencing span. A good agreement was seen between the different modality conditions that were studied (auditory, visual, & auditory-visual) for the different memory skills measures (memory scores, sequencing scores, memory span, & sequencing span). A relatively lower agreement was noted only between the auditory and visual modalities as well as between the visual and auditory-visual modality conditions for the memory scores, measured using Bland-Altman plots. The study highlights the efficacy of using analogous stimuli to assess the auditory, visual as well as combined modalities. The study supports the view that the performance of children on different memory skills was better through the auditory modality compared to the visual modality. Copyright © 2017 Elsevier B.V. All rights reserved.
Experiment Evaluation of Bifurcation in Sands
NASA Technical Reports Server (NTRS)
Alshibi, Khalid A.; Sture, Stein
2000-01-01
The basic principles of bifurcation analysis have been established by several investigators, however several issues remain unresolved, specifically how do stress level, grain size distribution, and boundary conditions affect general bifurcation phenomena in pressure sensitive and dilatant materials. General geometrical and kinematics conditions for moving surfaces of discontinuity was derived and applied to problems of instability of solids. In 1962, the theoretical framework of bifurcation by studying the acceleration waves in elasto-plastic (J2) solids were presented. Bifurcation analysis for more specific forms of constitutive behavior was examined by studying localization in pressure-sensitive, dilatant materials, however, analyses were restricted to plane deformation states only. Bifurcation analyses were presented and applied to predict shear band formations in sand under plane strain condition. The properties of discontinuous bifurcation solutions for elastic-plastic solids under axisymmetric and plane strain loading conditions were studied. The study focused on theory, but also references and comparisons to experiments were made. The current paper includes a presentation of a summary of bifurcation analyses for biaxial and triaxial (axisymmetric) loading conditions. The Coulomb model is implemented using incremental piecewise scheme to predict the constitutive relations and shear band inclination angles. Then, a comprehensive evaluation of bifurcation phenomena is presented based on data from triaxial experiments performed under microgravity conditions aboard the Space Shuttle under very low effective confining pressure (0.05 to 1.30 kPa), in which very high peak friction angles (47 to 75 degrees) and dilatancy angles (30 to 31 degrees) were measured. The evaluation will be extended to include biaxial experiments performed on the same material under low (10 kPa) and moderate (100 kPa) confining pressures. A comparison between the behavior under biaxial and triaxial loading conditions will be presented, and related issues concerning influence of confining pressure will be discussed.
How do tablet properties influence swallowing behaviours?
Yamamoto, Shinya; Taniguchi, Hiroshige; Hayashi, Hirokazu; Hori, Kazuhiro; Tsujimura, Takanori; Nakamura, Yuki; Sato, Hideaki; Inoue, Makoto
2014-01-01
Behavioural performance of tablet swallowing was evaluated with different tablet conditions in terms of size, number and surface coating. Four different types of tablets were prepared: small or large, and with or without a surface coating. Fourteen normal male adults were instructed to swallow the prepared tablets with 15 ml of water. The number of tablets in one trial was changed from one to three. To evaluate swallowing and tablet transport, electromyographic activity was recorded in the left suprahyoid muscles, and videofluorographic images were examined. All tablet conditions (size, number and surface coating) affected the swallowing performance in terms of total number of swallows, electromyographic burst patterns and location of remaining tablets. Increases in the size and number of tablets increased the number of swallows and electromyographic burst area and duration. In addition, all of these parameters increased while swallowing tablets without a coating compared with tablets with a coating. Location of the remaining tablets was mainly within the mouth. This study only clarified the normal pattern of tablet swallowing under several conditions in healthy subjects, but the results may facilitate comprehensive evaluation and treatment planning in terms of administering medication to dysphagic patients. © 2013 Royal Pharmaceutical Society.
Uncertainty in air quality observations using low-cost sensors
NASA Astrophysics Data System (ADS)
Castell, Nuria; Dauge, Franck R.; Dongol, Rozina; Vogt, Matthias; Schneider, Philipp
2016-04-01
Air pollution poses a threat to human health, and the WHO has classified air pollution as the world's largest single environmental health risk. In Europe, the majority of the population lives in areas where air quality levels frequently exceed WHO's ambient air quality guidelines. The emergence of low-cost, user-friendly and very compact air pollution platforms allowing observations at high spatial resolution in near real-time, provides us with new opportunities to simultaneously enhance existing monitoring systems as well as enable citizens to engage in more active environmental monitoring (citizen science). However the data sets generated by low-cost sensors show often questionable data quality. For many sensors, neither their error characteristics nor how their measurement capability holds up over time or through a range of environmental conditions, have been evaluated. We have conducted an exhaustive evaluation of the commercial low-cost platform AQMesh (measuring NO, NO2, CO, O3, PM10 and PM2.5) in laboratory and in real-world conditions in the city of Oslo (Norway). Co-locations in field of 24 platforms were conducted over a 6 month period (April to September 2015) allowing to characterize the temporal variability in the performance. Additionally, the field performance included the characterization on different monitoring urban monitoring sites characteristic of both traffic and background conditions. All the evaluations have been conducted against CEN reference method analyzers maintained according to the Norwegian National Reference Laboratory quality system. The results show clearly that a good performance in laboratory does not imply similar performance in real-world outdoor conditions. Moreover, laboratory calibration is not suitable for subsequent measurements in urban environments. In order to reduce the errors, sensors require on-site field calibration. Even after such field calibration, the platforms show a significant variability in the performance due to changes in the environmental conditions. Currently there is a lack of testing to ensure adequate sensor performance prior to marketing such instruments. Even when manufacturers provide detailed specification sheets, there is little guarantee that the specifications can actually be met in real-world conditions. Data quality is a pertinent concern, especially when citizens are collecting and interpreting the data by themselves. Poor or unknown data quality can lead to incorrect or inappropriate decisions. We present the experiences gained within the EU project CITI-SENSE, where low-cost sensors are one of the tools employed to empower citizens in air quality issues.
Gracia-Romero, Adrian; Kefauver, Shawn C.; Vergara-Díaz, Omar; Zaman-Allah, Mainassara A.; Prasanna, Boddupalli M.; Cairns, Jill E.; Araus, José L.
2017-01-01
Low soil fertility is one of the factors most limiting agricultural production, with phosphorus deficiency being among the main factors, particularly in developing countries. To deal with such environmental constraints, remote sensing measurements can be used to rapidly assess crop performance and to phenotype a large number of plots in a rapid and cost-effective way. We evaluated the performance of a set of remote sensing indices derived from Red-Green-Blue (RGB) images and multispectral (visible and infrared) data as phenotypic traits and crop monitoring tools for early assessment of maize performance under phosphorus fertilization. Thus, a set of 26 maize hybrids grown under field conditions in Zimbabwe was assayed under contrasting phosphorus fertilization conditions. Remote sensing measurements were conducted in seedlings at two different levels: at the ground and from an aerial platform. Within a particular phosphorus level, some of the RGB indices strongly correlated with grain yield. In general, RGB indices assessed at both ground and aerial levels correlated in a comparable way with grain yield except for indices a* and u*, which correlated better when assessed at the aerial level than at ground level and Greener Area (GGA) which had the opposite correlation. The Normalized Difference Vegetation Index (NDVI) evaluated at ground level with an active sensor also correlated better with grain yield than the NDVI derived from the multispectral camera mounted in the aerial platform. Other multispectral indices like the Soil Adjusted Vegetation Index (SAVI) performed very similarly to NDVI assessed at the aerial level but overall, they correlated in a weaker manner with grain yield than the best RGB indices. This study clearly illustrates the advantage of RGB-derived indices over the more costly and time-consuming multispectral indices. Moreover, the indices best correlated with GY were in general those best correlated with leaf phosphorous content. However, these correlations were clearly weaker than against grain yield and only under low phosphorous conditions. This work reinforces the effectiveness of canopy remote sensing for plant phenotyping and crop management of maize under different phosphorus nutrient conditions and suggests that the RGB indices are the best option. PMID:29230230
The influence of talker and foreign-accent variability on spoken word identification.
Bent, Tessa; Holt, Rachael Frush
2013-03-01
In spoken word identification and memory tasks, stimulus variability from numerous sources impairs performance. In the current study, the influence of foreign-accent variability on spoken word identification was evaluated in two experiments. Experiment 1 used a between-subjects design to test word identification in noise in single-talker and two multiple-talker conditions: multiple talkers with the same accent and multiple talkers with different accents. Identification performance was highest in the single-talker condition, but there was no difference between the single-accent and multiple-accent conditions. Experiment 2 further explored word recognition for multiple talkers in single-accent versus multiple-accent conditions using a mixed design. A detriment to word recognition was observed in the multiple-accent condition compared to the single-accent condition, but the effect differed across the language backgrounds tested. These results demonstrate that the processing of foreign-accent variation may influence word recognition in ways similar to other sources of variability (e.g., speaking rate or style) in that the inclusion of multiple foreign accents can result in a small but significant performance decrement beyond the multiple-talker effect.
SiC Composite for Fuel Structure Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yueh, Ken
Extensive evaluation was performed to determine the suitability of using SiC composite as a boiling water reactor (BWR) fuel channel material. A thin walled SiC composite box, 10 cm in dimension by approximately 1.5 mm wall thickness was fabricated using chemical vapor deposition (CVD) for testing. Mechanical test results and performance evaluations indicate the material could meet BWR channel mechanical design requirement. However, large mass loss of up to 21% was measured in in-pile corrosion test under BWR-like conditions in under 3 months of irradiation. A fresh sister sample irradiated in a follow-up cycle under PWR conditions showed no measureablemore » weight loss and thus supports the hypothesis that the oxidizing condition of the BWR-like coolant chemistry was responsible for the high corrosion rate. A thermodynamic evaluation showed SiC is not stable and the material may oxidize to form SiO 2 and CO 2. Silica has demonstrated stability in high temperature steam environment and form a protective oxide layer under severe accident conditions. However, it does not form a protective layer in water under normal BWR operational conditions due to its high solubility. Corrosion product stabilization by modifying the SiC CVD surface is an approach evaluated in this study to mitigate the high corrosion rate. Titanium and zirconium have been selected as stabilizing elements since both TiSiO 4 and ZrSiO 4 are insoluble in water. Corrosion test results in oxygenated water autoclave indicate TiSiO4 does not form a protective layer. However, zirconium doped test samples appear to form a stable continuous layer of ZrSiO 4 during the corrosion process. Additional process development is needed to produce a good ZrSiC coating to verify functionality of the mitigation concept.« less
Santos, Rafael D; Boote, Kenneth J; Sollenberger, Lynn E; Neves, Andre L A; Pereira, Luiz G R; Scherer, Carolina B; Gonçalves, Lucio C
2017-01-01
Forage production is primarily limited by weather conditions under dryland production systems in Brazilian semi-arid regions, therefore sowing at the appropriate time is critical. The objectives of this study were to evaluate the CSM-CERES-Pearl Millet model from the DSSAT software suite for its ability to simulate growth, development, and forage accumulation of pearl millet [ Pennisetum glaucum (L.) R.] at three Brazilian semi-arid locations, and to use the model to study the impact of different sowing dates on pearl millet performance for forage. Four pearl millet cultivars were grown during the 2011 rainy season in field experiments conducted at three Brazilian semi-arid locations, under rainfed conditions. The genetic coefficients of the four pearl millet cultivars were calibrated for the model, and the model performance was evaluated with experimental data. The model was run for 14 sowing dates using long-term historical weather data from three locations, to determine the optimum sowing window. Results showed that performance of the model was satisfactory as indicated by accurate simulation of crop phenology and forage accumulation against measured data. The optimum sowing window varied among locations depending on rainfall patterns, although showing the same trend for cultivars within the site. The best sowing windows were from 15 April to 15 May for the Bom Conselho location; 12 April to 02 May for Nossa Senhora da Gloria; and 17 April to 25 May for Sao Bento do Una. The model can be used as a tool to evaluate the effect of sowing date on forage pearl millet performance in Brazilian semi-arid conditions.
Aircraft Engine Sensor/Actuator/Component Fault Diagnosis Using a Bank of Kalman Filters
NASA Technical Reports Server (NTRS)
Kobayashi, Takahisa; Simon, Donald L. (Technical Monitor)
2003-01-01
In this report, a fault detection and isolation (FDI) system which utilizes a bank of Kalman filters is developed for aircraft engine sensor and actuator FDI in conjunction with the detection of component faults. This FDI approach uses multiple Kalman filters, each of which is designed based on a specific hypothesis for detecting a specific sensor or actuator fault. In the event that a fault does occur, all filters except the one using the correct hypothesis will produce large estimation errors, from which a specific fault is isolated. In the meantime, a set of parameters that indicate engine component performance is estimated for the detection of abrupt degradation. The performance of the FDI system is evaluated against a nonlinear engine simulation for various engine faults at cruise operating conditions. In order to mimic the real engine environment, the nonlinear simulation is executed not only at the nominal, or healthy, condition but also at aged conditions. When the FDI system designed at the healthy condition is applied to an aged engine, the effectiveness of the FDI system is impacted by the mismatch in the engine health condition. Depending on its severity, this mismatch can cause the FDI system to generate incorrect diagnostic results, such as false alarms and missed detections. To partially recover the nominal performance, two approaches, which incorporate information regarding the engine s aging condition in the FDI system, will be discussed and evaluated. The results indicate that the proposed FDI system is promising for reliable diagnostics of aircraft engines.
NASA Technical Reports Server (NTRS)
Potapczuk, Mark G.; Berkowitz, Brian M.
1989-01-01
An investigation of the ice accretion pattern and performance characteristics of a multi-element airfoil was undertaken in the NASA Lewis 6- by 9-Foot Icing Research Tunnel. Several configurations of main airfoil, slat, and flaps were employed to examine the effects of ice accretion and provide further experimental information for code validation purposes. The text matrix consisted of glaze, rime, and mixed icing conditions. Airflow and icing cloud conditions were set to correspond to those typical of the operating environment anticipated tor a commercial transport vehicle. Results obtained included ice profile tracings, photographs of the ice accretions, and force balance measurements obtained both during the accretion process and in a post-accretion evaluation over a range of angles of attack. The tracings and photographs indicated significant accretions on the slat leading edge, in gaps between slat or flaps and the main wing, on the flap leading-edge surfaces, and on flap lower surfaces. Force measurments indicate the possibility of severe performance degradation, especially near C sub Lmax, for both light and heavy ice accretion and performance analysis codes presently in use. The LEWICE code was used to evaluate the ice accretion shape developed during one of the rime ice tests. The actual ice shape was then evaluated, using a Navier-Strokes code, for changes in performance characteristics. These predicted results were compared to the measured results and indicate very good agreement.
Development and preliminary evaluation of a pediatric Spanish-English speech perception task.
Calandruccio, Lauren; Gomez, Bianca; Buss, Emily; Leibold, Lori J
2014-06-01
The purpose of this study was to develop a task to evaluate children's English and Spanish speech perception abilities in either noise or competing speech maskers. Eight bilingual Spanish-English and 8 age-matched monolingual English children (ages 4.9-16.4 years) were tested. A forced-choice, picture-pointing paradigm was selected for adaptively estimating masked speech reception thresholds. Speech stimuli were spoken by simultaneous bilingual Spanish-English talkers. The target stimuli were 30 disyllabic English and Spanish words, familiar to 5-year-olds and easily illustrated. Competing stimuli included either 2-talker English or 2-talker Spanish speech (corresponding to target language) and spectrally matched noise. For both groups of children, regardless of test language, performance was significantly worse for the 2-talker than for the noise masker condition. No difference in performance was found between bilingual and monolingual children. Bilingual children performed significantly better in English than in Spanish in competing speech. For all listening conditions, performance improved with increasing age. Results indicated that the stimuli and task were appropriate for speech recognition testing in both languages, providing a more conventional measure of speech-in-noise perception as well as a measure of complex listening. Further research is needed to determine performance for Spanish-dominant listeners and to evaluate the feasibility of implementation into routine clinical use.
Aiding Vertical Guidance Understanding
NASA Technical Reports Server (NTRS)
Feary, Michael; McCrobie, Daniel; Alkin, Martin; Sherry, Lance; Polson, Peter; Palmer, Everett; McQuinn, Noreen
1998-01-01
A two-part study was conducted to evaluate modern flight deck automation and interfaces. In the first part, a survey was performed to validate the existence of automation surprises with current pilots. Results indicated that pilots were often surprised by the behavior of the automation. There were several surprises that were reported more frequently than others. An experimental study was then performed to evaluate (1) the reduction of automation surprises through training specifically for the vertical guidance logic, and (2) a new display that describes the flight guidance in terms of aircraft behaviors instead of control modes. The study was performed in a simulator that was used to run a complete flight with actual airline pilots. Three groups were used to evaluate the guidance display and training. In the training, condition, participants went through a training program for vertical guidance before flying the simulation. In the display condition, participants ran through the same training program and then flew the experimental scenario with the new Guidance-Flight Mode Annunciator (G-FMA). Results showed improved pilot performance when given training specifically for the vertical guidance logic and greater improvements when given the training and the new G-FMA. Using actual behavior of the avionics to design pilot training and FMA is feasible, and when the automated vertical guidance mode of the Flight Management System is engaged, the display of the guidance mode and targets yields improved pilot performance.
Removal of organic carbon and nitrogen in a membraneless flow-through microbial electrolysis cell.
Hussain, Abid; Lebrun, Frédérique Matteau; Tartakovsky, Boris
2017-07-01
This study evaluated performance of an upflow membraneless microbial electrolysis cell (MEC) with flow-through electrodes for wastewater treatment. First, methane production and COD removal were evaluated in continuous flow experiments carried out using synthetic and municipal wastewater. A 29-75% increase in methane production was observed under bioelectrochemical conditions as compared to an anaerobic control. Next, simultaneous removal of COD and nitrogen was studied under microaerobic conditions created by continuous air injection to the anodic compartment of the MEC. While the presence of oxygen decreased Coulombic efficiency due to aerobic degradation of COD, enhanced ammonium removal with near zero nitrite and nitrate effluent concentrations was observed. Evidence of direct ammonium oxidation at the anode as well as nitrite and nitrate reduction at the cathode was obtained by comparing performances of MECs operated under anaerobic and microaerobic conditions with the control reactor operated at zero applied voltage. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.
Santos, Lívia; Rodrigues, Diana; Lira, Madalena; Oliveira, Rosario; Real Oliveira, M Elisabete C D; Vilar, Eva Yebra-Pimentel; Azeredo, Joana
2007-05-01
In this study, the effect of the natural surfactants octylglucoside and sodium cholate in inhibiting Staphylococcus epidermidis and Pseudomonas aeruginosa adhesion to conventional and silicone-hydrogel contact lenses (CL) was assessed. Hydrophobicity was also evaluated to conditioned and nonconditioned CL. The inhibiting effect of the tested surfactants was determined through "in vitro" adhesion studies to conditioned and nonconditioned CL followed by image acquisition and cell enumeration. Hydrophobicity was evaluated through contact angle measurements using the advancing type technique on air. Sodium cholate exhibits a very low capability to inhibit microbial adhesion. Conversely, octylglucoside effectively inhibited microbial adhesion in both types of lenses. This surfactant exhibited an even greater performance than a multipurpose lens care solution used as control. Octylglucoside was the only tested surfactant able to lower the hydrophobicity of all CL, which can explain its high performance. The results obtained in this study point out the potential of octylglucoside as a conditioning agent to prevent microbial colonization.
Safety and Performance Analysis of the Non-Radar Oceanic/Remote Airspace In-Trail Procedure
NASA Technical Reports Server (NTRS)
Carreno, Victor A.; Munoz, Cesar A.
2007-01-01
This document presents a safety and performance analysis of the nominal case for the In-Trail Procedure (ITP) in a non-radar oceanic/remote airspace. The analysis estimates the risk of collision between the aircraft performing the ITP and a reference aircraft. The risk of collision is only estimated for the ITP maneuver and it is based on nominal operating conditions. The analysis does not consider human error, communication error conditions, or the normal risk of flight present in current operations. The hazards associated with human error and communication errors are evaluated in an Operational Hazards Analysis presented elsewhere.
NASA Astrophysics Data System (ADS)
Al-Ajmi, R. M.; Abou-Ziyan, H. Z.; Mahmoud, M. A.
2012-01-01
This paper reports the results of a comprehensive study that aimed at identifying best neural network architecture and parameters to predict subcooled boiling characteristics of engine oils. A total of 57 different neural networks (NNs) that were derived from 14 different NN architectures were evaluated for four different prediction cases. The NNs were trained on experimental datasets performed on five engine oils of different chemical compositions. The performance of each NN was evaluated using a rigorous statistical analysis as well as careful examination of smoothness of predicted boiling curves. One NN, out of the 57 evaluated, correctly predicted the boiling curves for all cases considered either for individual oils or for all oils taken together. It was found that the pattern selection and weight update techniques strongly affect the performance of the NNs. It was also revealed that the use of descriptive statistical analysis such as R2, mean error, standard deviation, and T and slope tests, is a necessary but not sufficient condition for evaluating NN performance. The performance criteria should also include inspection of the smoothness of the predicted curves either visually or by plotting the slopes of these curves.
A study for high accuracy measurement of residual stress by deep hole drilling technique
NASA Astrophysics Data System (ADS)
Kitano, Houichi; Okano, Shigetaka; Mochizuki, Masahito
2012-08-01
The deep hole drilling technique (DHD) received much attention in recent years as a method for measuring through-thickness residual stresses. However, some accuracy problems occur when residual stress evaluation is performed by the DHD technique. One of the reasons is that the traditional DHD evaluation formula applies to the plane stress condition. The second is that the effects of the plastic deformation produced in the drilling process and the deformation produced in the trepanning process are ignored. In this study, a modified evaluation formula, which is applied to the plane strain condition, is proposed. In addition, a new procedure is proposed which can consider the effects of the deformation produced in the DHD process by investigating the effects in detail by finite element (FE) analysis. Then, the evaluation results obtained by the new procedure are compared with that obtained by traditional DHD procedure by FE analysis. As a result, the new procedure evaluates the residual stress fields better than the traditional DHD procedure when the measuring object is thick enough that the stress condition can be assumed as the plane strain condition as in the model used in this study.
NASA Astrophysics Data System (ADS)
Herran, C. Leigh; Huang, Yong; Chai, Wenxuan
2012-08-01
Microspheres, small spherical (polymeric) particles with or without second phase materials embedded or encapsulated, are important for many biomedical applications such as drug delivery and organ printing. Scale-up fabrication with the ability to precisely control the microsphere size and morphology has always been of great manufacturing interest. The objective of this work is to experimentally study the performance differences of bipolar and tripolar excitation waveforms in using drop-on-demand (DOD)-based single nozzle jetting for alginate microsphere fabrication. The fabrication performance has been evaluated based on the formability of alginate microspheres as a function of materials properties (sodium alginate and calcium chloride concentrations) and operating conditions. The operating conditions for each excitation include voltage rise/fall times, dwell times and excitation voltage amplitudes. Overall, the bipolar excitation is more robust in making spherical, monodispersed alginate microspheres as good microspheres for its wide working range of material properties and operating conditions, especially during the fabrication of highly viscous materials such as the 2% sodium alginate solution. For both bipolar and tripolar excitations, the sodium alginate concentration and the voltage dwell times should be carefully selected to achieve good microsphere formability.
Lai, Ying-Hui; Chen, Fei; Wang, Syu-Siang; Lu, Xugang; Tsao, Yu; Lee, Chin-Hui
2017-07-01
In a cochlear implant (CI) speech processor, noise reduction (NR) is a critical component for enabling CI users to attain improved speech perception under noisy conditions. Identifying an effective NR approach has long been a key topic in CI research. Recently, a deep denoising autoencoder (DDAE) based NR approach was proposed and shown to be effective in restoring clean speech from noisy observations. It was also shown that DDAE could provide better performance than several existing NR methods in standardized objective evaluations. Following this success with normal speech, this paper further investigated the performance of DDAE-based NR to improve the intelligibility of envelope-based vocoded speech, which simulates speech signal processing in existing CI devices. We compared the performance of speech intelligibility between DDAE-based NR and conventional single-microphone NR approaches using the noise vocoder simulation. The results of both objective evaluations and listening test showed that, under the conditions of nonstationary noise distortion, DDAE-based NR yielded higher intelligibility scores than conventional NR approaches. This study confirmed that DDAE-based NR could potentially be integrated into a CI processor to provide more benefits to CI users under noisy conditions.
USDA-ARS?s Scientific Manuscript database
Phosphorus adsorption by a water treatment residual was tested through Langmuir and linear sorption isotherms and applied in the Soil and Water Assessment Tool (SWAT). The objective of this study was to use laboratory and greenhouse experimental phosphorus data to evaluate the performance of a modi...
12 CFR Appendix C to Subpart A of... - Appendix C to Subpart A of Part 327
Code of Federal Regulations, 2010 CFR
2010-01-01
... reports. Stress Considerations Ability to Withstand Stress Conditions • Internal analyses of portfolio.... • Stress scenario development and analyses. • Results of stress tests or scenario analyses that show the.... an evaluation of credit portfolio performance under varying stress scenarios. ii. an evaluation of...
USDA-ARS?s Scientific Manuscript database
1. To evaluate the performance of visible and near-infrared (Vis/NIR) spectroscopic models for discriminating true pale, soft and exudative (PSE), normal and dark, firm and dry (DFD) broiler breast meat in different conditions of preprocessing methods, spectral ranges, characteristic wavelength sele...
12 CFR Appendix C to Subpart A of... - Appendix C to Subpart A of Part 327
Code of Federal Regulations, 2011 CFR
2011-01-01
... reports. Stress Considerations Ability to Withstand Stress Conditions • Internal analyses of portfolio.... • Stress scenario development and analyses. • Results of stress tests or scenario analyses that show the.... an evaluation of credit portfolio performance under varying stress scenarios. ii. an evaluation of...
10 CFR 50.65 - Requirements for monitoring the effectiveness of maintenance at nuclear power plants.
Code of Federal Regulations, 2010 CFR
2010-01-01
... with safety and, where practical, take into account industry-wide operating experience. When the...) of this section is not required where it has been demonstrated that the performance or condition of a... evaluations does not exceed 24 months. The evaluations shall take into account, where practical, industry-wide...
Effects of Evaluation Expectation on Artistic Creativity.
ERIC Educational Resources Information Center
Amabile, Teresa M.
Conditions are examined under which the imposition of an extrinsic constraint upon performance of an activity can lead to decrements in creativity. Female college students worked on an art activity either with or without the expectation of external evaluation. In addition, subjects were asked to focus upon either the creative or the technical…
Evaluating a new shade for feedlot cattle performance and heat stress
USDA-ARS?s Scientific Manuscript database
Heat stress in cattle results in decreased feed intake, lower daily gain and potentially death in susceptible animals under intense conditions. A study was carried out during the summer of 2013 on the USDA-ARS U.S. Meat Animal Research Center feedlot evaluating the impact of shade on environmental c...
Subjective evaluation of H.265/HEVC based dynamic adaptive video streaming over HTTP (HEVC-DASH)
NASA Astrophysics Data System (ADS)
Irondi, Iheanyi; Wang, Qi; Grecos, Christos
2015-02-01
The Dynamic Adaptive Streaming over HTTP (DASH) standard is becoming increasingly popular for real-time adaptive HTTP streaming of internet video in response to unstable network conditions. Integration of DASH streaming techniques with the new H.265/HEVC video coding standard is a promising area of research. The performance of HEVC-DASH systems has been previously evaluated by a few researchers using objective metrics, however subjective evaluation would provide a better measure of the user's Quality of Experience (QoE) and overall performance of the system. This paper presents a subjective evaluation of an HEVC-DASH system implemented in a hardware testbed. Previous studies in this area have focused on using the current H.264/AVC (Advanced Video Coding) or H.264/SVC (Scalable Video Coding) codecs and moreover, there has been no established standard test procedure for the subjective evaluation of DASH adaptive streaming. In this paper, we define a test plan for HEVC-DASH with a carefully justified data set employing longer video sequences that would be sufficient to demonstrate the bitrate switching operations in response to various network condition patterns. We evaluate the end user's real-time QoE online by investigating the perceived impact of delay, different packet loss rates, fluctuating bandwidth, and the perceived quality of using different DASH video stream segment sizes on a video streaming session using different video sequences. The Mean Opinion Score (MOS) results give an insight into the performance of the system and expectation of the users. The results from this study show the impact of different network impairments and different video segments on users' QoE and further analysis and study may help in optimizing system performance.
Dynamic Performance Evaluation of PV Integration
NASA Astrophysics Data System (ADS)
Gao, Ruilin; Jiang, Anwen; Chen, Hongjin
2018-03-01
Topics on adaptability of Grid-connected photovoltaic systems (GCPVS) under sag conditions has been proposed. A basic low-voltage-ride-through (LVRT) strategy widely used in engineering practice is taken in this paper and manages to ride through different sag conditions. The role of hardware protection has been discussed in detail. By simulation validated that the proposed GCPVS have strong adaptability
Thermionic reactor power conditioner design for nuclear electric propulsion.
NASA Technical Reports Server (NTRS)
Jacobsen, A. S.; Tasca, D. M.
1971-01-01
Consideration of the effects of various thermionic reactor parameters and requirements upon spacecraft power conditioning design. A basic spacecraft is defined using nuclear electric propulsion, requiring approximately 120 kWe. The interrelationships of reactor operating characteristics and power conditioning requirements are discussed and evaluated, and the effects on power conditioner design and performance are presented.
Teaching an Individual with Severe Intellectual Delay to Request Assistance Conditionally
ERIC Educational Resources Information Center
Reichle, Joe; McComas, Jennifer; Dahl, Norm; Solberg, Gina; Pierce, Sarah; Smith, David
2005-01-01
The purpose of this study was to evaluate intervention procedures to teach conditional use of a communicative request for assistance and independent task performance. A 40-year-old man with autism and severe mental retardation with a history of escape-related problems was taught to use a graphic symbol to request assistance and to engage…
Choi, Hyun Ho; Lee, Ju Hwan; Kim, Sung Min; Park, Sung Yun
2015-01-01
Here, the speckle noise in ultrasonic images is removed using an image fusion-based denoising method. To optimize the denoising performance, each discrete wavelet transform (DWT) and filtering technique was analyzed and compared. In addition, the performances were compared in order to derive the optimal input conditions. To evaluate the speckle noise removal performance, an image fusion algorithm was applied to the ultrasound images, and comparatively analyzed with the original image without the algorithm. As a result, applying DWT and filtering techniques caused information loss and noise characteristics, and did not represent the most significant noise reduction performance. Conversely, an image fusion method applying SRAD-original conditions preserved the key information in the original image, and the speckle noise was removed. Based on such characteristics, the input conditions of SRAD-original had the best denoising performance with the ultrasound images. From this study, the best denoising technique proposed based on the results was confirmed to have a high potential for clinical application.
Does McNemar's test compare the sensitivities and specificities of two diagnostic tests?
Kim, Soeun; Lee, Woojoo
2017-02-01
McNemar's test is often used in practice to compare the sensitivities and specificities for the evaluation of two diagnostic tests. For correct evaluation of accuracy, an intuitive recommendation is to test the diseased and the non-diseased groups separately so that the sensitivities can be compared among the diseased, and specificities can be compared among the healthy group of people. This paper provides a rigorous theoretical framework for this argument and study the validity of McNemar's test regardless of the conditional independence assumption. We derive McNemar's test statistic under the null hypothesis considering both assumptions of conditional independence and conditional dependence. We then perform power analyses to show how the result is affected by the amount of the conditional dependence under alternative hypothesis.
Impacts of Lateral Boundary Conditions on US Ozone ...
Chemical boundary conditions are a key input to regional-scale photochemical models. In this study, we perform annual simulations over North America with chemical boundary conditions prepared from two global models (GEOS-CHEM and Hemispheric CMAQ). Results indicate that the impacts of different boundary conditions on ozone can be significant throughout the year. The National Exposure Research Laboratory (NERL) Computational Exposure Division (CED) develops and evaluates data, decision-support tools, and models to be applied to media-specific or receptor-specific problem areas. CED uses modeling-based approaches to characterize exposures, evaluate fate and transport, and support environmental diagnostics/forensics with input from multiple data sources. It also develops media- and receptor-specific models, process models, and decision support tools for use both within and outside of EPA.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2014-10-01
In this project, Building America team IBACOS performed field testing in a new construction unoccupied test house in Pittsburgh, Pennsylvania to evaluate heating, ventilating, and air conditioning (HVAC) distribution systems during heating, cooling, and midseason conditions. Four air-based HVAC distribution systems were assessed:-a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, a system with transfer fans to the bedrooms, and a system with no ductwork to the bedrooms. The relative ability of each system was considered with respect to relevant Air Conditioning Contractors of America and ASHRAE standards for house temperature uniformity andmore » stability, respectively.« less
Vehicle test report: Electric Vehicle Associates electric conversion of an AMC Pacer
NASA Technical Reports Server (NTRS)
Price, T. W.; Wirth, V. A., Jr.; Pampa, M. F.
1981-01-01
The change of pace, an electric vehicle was tested. These tests were performed to characterize certain parameters of the electric vehicle pacer and to provide baseline data that can be used for the comparison of improved batteries that may be incorporated into the vehicle at a later time. The vehicle tests were concentrated on the electrical drive subsystem, the batteries, controller and motor. Coastdowns to characterize the road load, and range evaluations for both cyclic and constant speed conditions were performed. The vehicle's performance was evaluated by comparing its constant speed range performance with described vehicles. It is found that the pacer performance is approximately equal to the majority of the vehicles tested in the 1977 assessment.
Vehicle test report: Electric Vehicle Associates electric conversion of an AMC Pacer
NASA Technical Reports Server (NTRS)
Price, T. W.; Wirth, V. A., Jr.; Pompa, M. F.
1981-01-01
Tests were performed to characterize certain parameters of the EVA Pacer and to provide baseline data that can be used for the comparison of improved batteries that may be incorporated into the vehicle at a later time. The vehicle tests were concentrated on the electrical drive subsystem; i.e., the batteries, controller and motor. The tests included coastdowns to characterize the road load, and range evaluations for both cyclic and constant speed conditions. A qualitative evaluation of the vehicle's performance was made by comparing its constant speed range performance with other electric and hybrid vehicles. The Pacer performance was approximately equal to the majority of those vehicles assessed in 1977.
Effect of broad properties fuel on injector performance in a reverse flow combustor
NASA Technical Reports Server (NTRS)
Raddlebaugh, S. M.; Norgren, C. T.
1983-01-01
The effect of fuel type on the performance of various fuel injectors was investigated in a reverse flow combustor. Combustor performance and emissions are documented for simplex pressure atomizing, spill flow, and airblast fuel injectors using a broad properties fuel and compared with performance using Jet A fuel. Test conditions simulated a range of flight conditions including sea level take off, low and high altitude cruise, as well as a parametric evaluation of the effect of increased combustor loading. The baseline simplex injector produced higher emission levels with corresponding lower combustion efficiency with the broad properties fuel. There was little or not loss in performance by the two advanced concept injectors with the broad properties fuel. The airblast injector proved to be especially insensitive to fuel type.
Solar dynamic heat receiver thermal characteristics in low earth orbit
NASA Technical Reports Server (NTRS)
Wu, Y. C.; Roschke, E. J.; Birur, G. C.
1988-01-01
A simplified system model is under development for evaluating the thermal characteristics and thermal performance of a solar dynamic spacecraft energy system's heat receiver. Results based on baseline orbit, power system configuration, and operational conditions, are generated for three basic receiver concepts and three concentrator surface slope errors. Receiver thermal characteristics and thermal behavior in LEO conditions are presented. The configuration in which heat is directly transferred to the working fluid is noted to generate the best system and thermal characteristics. as well as the lowest performance degradation with increasing slope error.
Systems Design and Experimental Evaluation of a High-Altitude Relight Test Facility
NASA Astrophysics Data System (ADS)
Paxton, Brendan
Novel advances in gas turbine engine combustor technology, led by endeavors into fuel efficiency and demanding environmental regulations, have been fraught with performance and safety concerns. While the majority of low emissions gas turbine engine combustor technology has been necessary for power generation applications, the push for ultra-low NOx combustion in aircraft jet engines has been ever present. Recent state-of-the-art combustor designs notably tackle historic emissions challenges by operating at fuel-lean conditions, which are characterized by an increase in the amount of air flow sent to the primary combustion zone. While beneficial in reducing NOx emissions, the fuel-lean mechanisms that characterize these combustor designs rely heavily upon high-energy and high-velocity air flows to sufficiently mix and atomize fuel droplets, ultimately leading to flame stability concerns during low-power operation. When operating at high-altitude conditions, these issues are further exacerbated by the presence of low ambient air pressures and temperatures, which can lead to engine flame-out situations and hamper engine relight attempts. To aid academic and industrial research ventures into improving the high-altitude lean blow-out and relight performance of modern gas turbine engine combustor technologies, the High-Altitude Relight Test Facility (HARTF) was designed and constructed at the University of Cincinnati (UC) Combustion and Fire Research Laboratory (CFRL). Following its construction, an experimental evaluation of its abilities to facilitate optically-accessible ignition, combustion, and spray testing for gas turbine engine combustor hardware at simulated high-altitude conditions was performed. In its evaluation, performance limit references were established through testing of the HARTF vacuum and cryogenic air-chilling capabilities. These tests were conducted with regard to end-user control---the creation and the maintenance of a realistic high-altitude environment simulation. To evaluate future testing applications, as well as to understand the abilities of the HARTF to accommodate different sizes and configurations of industrial gas turbine engine combustor hardware, ignition testing was conducted at challenging high-altitude windmilling conditions with a linearly-arranged five-swirler array, replicating the implementation of a multi-cup combustor sector.
[Individual physical performance capacity with physiological and biochemical indicators of stress].
Bergert, K D; Nestler, K; Böttger, H; Schettler, R
1989-09-01
22 health male subjects were exposed by a combination of physical exercises and heat. Strain related physiological and biochemical parameters were measured. Different individual reactions were obtained under controlled conditions. In dependence on the individual performance an increased mobilisation of lactat, free fatty acids and catecholamines were found. The determination of aerob physical performance can be applied for the evaluation of working capacity.
Task and work performance on Skylab missions 2, 3, and 4: Time and motion study: Experiment M151
NASA Technical Reports Server (NTRS)
Kubis, J. F.; Mclaughlin, E. J.; Jackson, J. M.; Rusnak, R.; Mcbride, G. H.; Saxon, S. V.
1977-01-01
Human task performance was evaluated under weightlessness conditions during long duration space flight in order to study the characteristics of the adaptation function. Results show that despite pronounced variability in training schedules and in initial reaction to the Skylab environment, in-flight task performance was relatively equivalent among Skylab crews, and behavioral performance continued to improve from beginning to end of all missions.
Caradeux, J; Eixarch, E; Mazarico, E; Basuki, T R; Gratacós, E; Figueras, F
2018-02-01
Detection of fetal growth restriction (FGR) remains poor and most screening strategies rely on cross-sectional evaluation of fetal size during the third trimester. A longitudinal and individualized approach has been proposed as an alternative method of evaluation. The aim of this study was to compare second- to third-trimester longitudinal growth assessment to cross-sectional evaluation in the third trimester for the prediction of small-for-gestational age (SGA) and late FGR in low-risk singleton pregnancy. This was a prospective cohort study of 2696 unselected consecutive low-risk singleton pregnancies scanned at 21 ± 2 and 32 ± 2 weeks. For cross-sectional growth assessment, abdominal circumference (AC) measurements were transformed to z-values according the 21st-INTERGROWTH standards. Longitudinal growth assessment was performed by calculating the AC z-velocity and the second- to third-trimester AC conditional growth centile. Longitudinal assessment was compared with cross-sectional assessment at 32 weeks. Association of cross-sectional and longitudinal evaluations with SGA and late FGR was assessed by logistic regression analysis. Predictive performance was determined by receiver-operating characteristics curve analysis. In total, 210 (7.8%) newborns were classified as SGA and 103 (3.8%) as late FGR. Neither longitudinal measurement improved the association with SGA or late FGR provided by cross-sectional evaluation of AC z-score at 32 weeks. Areas under the curves of AC z-velocity and conditional AC growth were significantly smaller than those of cross-sectional AC z-scores (P < 0.001), although AC z-velocity performed significantly better than did conditional AC growth (P < 0.001). Longitudinal assessment of fetal growth from the second to third trimester has a low predictive capacity for SGA and late FGR in low-risk singleton pregnancy compared with cross-sectional growth evaluation. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.
USDA-ARS?s Scientific Manuscript database
The evaluation of transgenic plants commonly carried out under controlled conditions in culture rooms and greenhouses can give valuable information about the influence of introduced genes on transgenic plant phenotype. However, an overall assessment of plant performance can only be made by testing t...
ERIC Educational Resources Information Center
Yuretich, Richard F.; Khan, Samia A.; Leckie, R. Mark; Clement, John J.
2001-01-01
Transfers the environment of a large enrollment oceanography course by modifying lectures to include cooperative learning via interactive in-class exercises and directed discussion. Results of student surveys, course evaluations, and exam performance demonstrate that learning of the subject under these conditions has improved. (Author/SAH)
Economic Evaluation of Observatory Solar-Energy System
NASA Technical Reports Server (NTRS)
1982-01-01
Long-term economic performance of a commercial solar-energy system was analyzed and used to predict economic performance at four additional sites. Analysis described in report was done to demonstrate viability of design over a broad range of environmental/economic conditions. Topics covered are system description, study approach, economic analysis and system optimization.
42 CFR 418.58 - Condition of participation: Quality assessment and performance improvement.
Code of Federal Regulations, 2011 CFR
2011-10-01
... collected to do the following: (i) Monitor the effectiveness and safety of services and quality of care. (ii..., patient safety, and quality of care. (2) Performance improvement activities must track adverse patient... care and patient safety, and that all improvement actions are evaluated for effectiveness. (3) That one...
A SYSTEMS APPROACH UTILIZING GENERAL-PURPOSE AND SPECIAL-PURPOSE TEACHING MACHINES.
ERIC Educational Resources Information Center
SILVERN, LEONARD C.
IN ORDER TO IMPROVE THE EMPLOYEE TRAINING-EVALUATION METHOD, TEACHING MACHINES AND PERFORMANCE AIDS MUST BE PHYSICALLY AND OPERATIONALLY INTEGRATED INTO THE SYSTEM, THUS RETURNING TRAINING TO THE ACTUAL JOB ENVIRONMENT. GIVEN THESE CONDITIONS, TRAINING CAN BE MEASURED, CALIBRATED, AND CONTROLLED WITH RESPECT TO ACTUAL JOB PERFORMANCE STANDARDS AND…
Fuzzy Performance between Surface Fitting and Energy Distribution in Turbulence Runner
Liang, Zhongwei; Liu, Xiaochu; Ye, Bangyan; Brauwer, Richard Kars
2012-01-01
Because the application of surface fitting algorithms exerts a considerable fuzzy influence on the mathematical features of kinetic energy distribution, their relation mechanism in different external conditional parameters must be quantitatively analyzed. Through determining the kinetic energy value of each selected representative position coordinate point by calculating kinetic energy parameters, several typical algorithms of complicated surface fitting are applied for constructing microkinetic energy distribution surface models in the objective turbulence runner with those obtained kinetic energy values. On the base of calculating the newly proposed mathematical features, we construct fuzzy evaluation data sequence and present a new three-dimensional fuzzy quantitative evaluation method; then the value change tendencies of kinetic energy distribution surface features can be clearly quantified, and the fuzzy performance mechanism discipline between the performance results of surface fitting algorithms, the spatial features of turbulence kinetic energy distribution surface, and their respective environmental parameter conditions can be quantitatively analyzed in detail, which results in the acquirement of final conclusions concerning the inherent turbulence kinetic energy distribution performance mechanism and its mathematical relation. A further turbulence energy quantitative study can be ensured. PMID:23213287
NASA Technical Reports Server (NTRS)
Garafolo, Nicholas G.; Daniels, Christopher C.
2011-01-01
A novel docking seal was developed for the main interface seal of NASA s Low Impact Docking System (LIDS). This interface seal was designed to maintain acceptable leak rates while being exposed to the harsh environmental conditions of outer space. In this experimental evaluation, a candidate docking seal assembly called Engineering Development Unit (EDU58) was characterized and evaluated against the Constellation Project leak rate requirement. The EDU58 candidate seal assembly was manufactured from silicone elastomer S0383-70 vacuum molded in a metal retainer ring. Four seal designs were considered with unique characteristic heights. The leak rate performance was characterized through a mass point leak rate method by monitoring gas properties within an internal control volume. The leakage performance of the seals were described herein at representative docking temperatures of -50, +23, and +50 C for all four seal designs. Leak performance was also characterized at 100, 74, and 48 percent of full closure. For all conditions considered, the candidate seal assemblies met the Constellation Project leak rate requirement.
A multifaceted independent performance analysis of facial subspace recognition algorithms.
Bajwa, Usama Ijaz; Taj, Imtiaz Ahmad; Anwar, Muhammad Waqas; Wang, Xuan
2013-01-01
Face recognition has emerged as the fastest growing biometric technology and has expanded a lot in the last few years. Many new algorithms and commercial systems have been proposed and developed. Most of them use Principal Component Analysis (PCA) as a base for their techniques. Different and even conflicting results have been reported by researchers comparing these algorithms. The purpose of this study is to have an independent comparative analysis considering both performance and computational complexity of six appearance based face recognition algorithms namely PCA, 2DPCA, A2DPCA, (2D)(2)PCA, LPP and 2DLPP under equal working conditions. This study was motivated due to the lack of unbiased comprehensive comparative analysis of some recent subspace methods with diverse distance metric combinations. For comparison with other studies, FERET, ORL and YALE databases have been used with evaluation criteria as of FERET evaluations which closely simulate real life scenarios. A comparison of results with previous studies is performed and anomalies are reported. An important contribution of this study is that it presents the suitable performance conditions for each of the algorithms under consideration.
Wiggins, Mark; O'Hare, David
2003-01-01
Inappropriate and ineffective weather-related decision making continues to account for a significant proportion of general aviation fatalities in the United States and elsewhere. This study details the evaluation of a computer-based training system that was developed to provide visual pilots with the skills necessary to recognize and respond to the cues associated with deteriorating weather conditions during flight. A total of 66 pilots were assigned to one of two groups, and the evaluation process was undertaken at both a self-report and performance level. At the self-report level, the results suggested that pilots were more likely to use the cues following exposure to the training program. From a performance perspective, there is evidence to suggest that cue-based training can improve the timeliness of weather-related decision making during visual flight rules flight. Actual or potential applications of this research include the development of computer-based training systems for fault diagnosis in complex industrial environments.
Gear Fault Detection Effectiveness as Applied to Tooth Surface Pitting Fatigue Damage
NASA Technical Reports Server (NTRS)
Lewicki, David G.; Dempsey, Paula J.; Heath, Gregory F.; Shanthakumaran, Perumal
2010-01-01
A study was performed to evaluate fault detection effectiveness as applied to gear-tooth-pitting-fatigue damage. Vibration and oil-debris monitoring (ODM) data were gathered from 24 sets of spur pinion and face gears run during a previous endurance evaluation study. Three common condition indicators (RMS, FM4, and NA4 [Ed. 's note: See Appendix A-Definitions D were deduced from the time-averaged vibration data and used with the ODM to evaluate their performance for gear fault detection. The NA4 parameter showed to be a very good condition indicator for the detection of gear tooth surface pitting failures. The FM4 and RMS parameters perfomu:d average to below average in detection of gear tooth surface pitting failures. The ODM sensor was successful in detecting a significant 8lDOunt of debris from all the gear tooth pitting fatigue failures. Excluding outliers, the average cumulative mass at the end of a test was 40 mg.
Sheffer, C E; Penn, D L; Cassisi, J E
2001-01-01
The effects of self-presentation demands were evaluated through conversational probe (CP) role-play tasks. Participants (N = 29) were required to manage their self-presentations (i.e., the impression they made, in each of two conditions). During high impression management (IM) demand, participants were evaluated on their performance. During Low IM demand, participants evaluated a confederate's performance. The High IM demand condition produced significantly higher heart rate (HR) and self-reported anxiety. HR and self-reported anxiety accounted for a significant amount of the variance in criterion measures of social competence. Greater social competence during High IM was associated with higher HR. Greater social competence during Low IM was associated with lower HR and lower self-reported anxiety. Although preliminary, these results suggest that uncontrolled IM demands contributed to mixed results found within and between social anxiety studies in the literature. Implications for the treatment of social anxiety are discussed.
Ryan, David B; Colwell, Kenneth A; Throckmorton, Chandra S; Collins, Leslie M; Caves, Kevin; Sellers, Eric W
2018-03-01
The objective of this study was to investigate the performance of 3 brain-computer interface (BCI) paradigms in an amyotrophic lateral sclerosis (ALS) population (n = 11). Using a repeated-measures design, participants completed 3 BCI conditions: row/column (RCW), checkerboard (CBW), and gray-to-color (CBC). Based on previous studies, it is hypothesized that the CBC and CBW conditions will result in higher accuracy, information transfer rate, waveform amplitude, and user preference over the RCW condition. An offline dynamic stopping simulation will also increase information transfer rate. Higher mean accuracy was observed in the CBC condition (89.7%), followed by the CBW (84.3%) condition, and lowest in the RCW condition (78.7%); however, these differences did not reach statistical significance ( P = .062). Eight of the eleven participants preferred the CBC and the remaining three preferred the CBW conditions. The offline dynamic stopping simulation significantly increased information transfer rate ( P = .005) and decreased accuracy ( P < .000). The findings of this study suggest that color stimuli provide a modest improvement in performance and that participants prefer color stimuli over monochromatic stimuli. Given these findings, BCI paradigms that use color stimuli should be considered for individuals who have ALS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Todd, L.L.; Savage, R.T.; Vincent, R.L.
1983-01-01
The United States Army Aviation Engineering Flight Activity conducted level flight performance tests of the AH-1S (Prod) helicopter to provide data to determine the most fuel efficient operating conditions. Hot and cold weather test sites were used to extend the range of the advancing tip Mach number data to supplement existing AH-1S performance data. Preliminary analysis of non-dimensional data identifies the effects of compressibility on performance and shows a power penalty of as much as 6% at a high NR/theta. The power required characteristics determined by these tests can be combined with engine performance to determine the most fuel efficientmore » operating conditions.« less
Analysis of AIRS and IASI System Performance Under Clear and Cloudy Conditions
NASA Technical Reports Server (NTRS)
Aumann, Hartmut H.; Strow, L. Larrabee
2010-01-01
The radiometric and spectral system performance of space-borne infrared radiometers is generally specified and analyzed under strictly cloud-free, spatially uniform and warm conditions, with the assumption that the observed performance applies to the full dynamic range under clear and cloudy conditions and that random noise cancels for the evaluation of the radiometric accuracy. Such clear conditions are found in only one percent of the data. Ninety nine percent of the data include clouds, which produce spatially highly non-uniform scenes with 11 micrometers window brightness temperatures as low as 200K. We use AIRS and IASI radiance spectra to compare system performance under clear and a wide range of cloudy conditions. Although the two instruments are in polar orbits, with the ascending nodes separated by four hours, daily averages already reveal surprisingly similar measurements. The AIRS and IASI radiometric performance based on the mean of large numbers of observation is comparable and agrees within 200 mK over a wide range of temperatures. There are also some unexpected differences at the 200 -500 mK level, which are of significance for climate applications. The results were verified with data from July 2007 through January 2010, but many can already be gleaned from the analysis of a single day of data.
Kim, Saorin; Nhem, Sina; Dourng, Dany; Ménard, Didier
2015-03-14
Malaria rapid diagnostic tests (RDTs) are generally considered as point-of-care tests. However, most of the studies assessing the performance of malaria RDTs are conducted by research teams that are not representative of the classical end-users, who are typically unskilled in traditional laboratory techniques for diagnosing malaria. To evaluate the performance of a malaria RDT by end-users in a malaria-endemic area, a study protocol was designed and the VIKIA Malaria Ag Pf/Pan test, previously evaluated in 2013, was re-evaluated by representative end-users. Twenty end-users with four different profiles in seven communes in Kampot Province (Cambodia) were selected. A set of 20 calibrated aliquots, including negative samples, low positive samples (200 parasites/μL of Plasmodium falciparum and Plasmodium vivax) and high positive samples (2,000 parasites/μL of P. falciparum and P. vivax) was used. Testing was performed directly by the end-users without any practical training on the VIKIA Malaria Ag Pf/Pan kit. All results obtained by the end-users were consistent with the expected results, except for the low positive (200 parasites/μL) P. vivax aliquot (35% of concordant results). No significant difference was observed between the different end-users. End-user interviews evaluating ease-of-use and ease-of-reading of the VIKIA Malaria Ag Pf/Pan kit recorded 159 positive answers and only one negative answer. Out of 20 end-users, only one considered the test was not easy to perform with the support of the quick guide. The data presented in this study clearly demonstrate that the performance of the VIKIA Malaria Ag Pf/Pan test when performed by traditional end-users in field conditions is similar to that obtained by a research team and that this RDT can be considered as a point-of-care tool/assay. Furthermore, the protocol designed for this study could be used systematically in parallel to conventional evaluation studies to determine the performance of malaria RDTs in field conditions.
[Surgical treatment of colonic and rectal tumors].
Verushkin, I I; Ratmanov, A M; Kotomin, S V; Sharnov, V A; Verushkina, N I
1996-01-01
The study included three groups of patients with rectal and colonic tumors operated on under emergency and routine conditions. The percentage of emergency operations proved rather high, surgery being performed under both hospital and field conditions. Causes for calls have been evaluated and extent of surgery versus operating conditions and immediate results in each group assessed. Operating under hospital conditions is recommended for carrying out procedures like that of Hartman involving obligatory removal of tumor and verification of diagnosis. Reconstructive surgery should be performed in specialized wards of a regional clinic. Higher expertise of rural surgeons as well as increased competence of general practitioners in oncopathology, timely inclusion of oncologists into on-call teams of doctors and hospitalization of patients into specialized wards contribute to higher effectiveness of treatment of bowel pathologies.
NASA Astrophysics Data System (ADS)
Papapostolou, Vasileios; Zhang, Hang; Feenstra, Brandon J.; Polidori, Andrea
2017-12-01
A state-of-the-art integrated chamber system has been developed for evaluating the performance of low-cost air quality sensors. The system contains two professional grade chamber enclosures. A 1.3 m3 stainless-steel outer chamber and a 0.11 m3 Teflon-coated stainless-steel inner chamber are used to create controlled aerosol and gaseous atmospheres, respectively. Both chambers are temperature and relative humidity controlled with capability to generate a wide range of environmental conditions. The system is equipped with an integrated zero-air system, an ozone and two aerosol generation systems, a dynamic dilution calibrator, certified gas cylinders, an array of Federal Reference Method (FRM), Federal Equivalent Method (FEM), and Best Available Technology (BAT) reference instruments and an automated control and sequencing software. Our experiments have demonstrated that the chamber system is capable of generating stable and reproducible aerosol and gas concentrations at low, medium, and high levels. This paper discusses the development of the chamber system along with the methods used to quantitatively evaluate sensor performance. Considering that a significant number of academic and research institutions, government agencies, public and private institutions, and individuals are becoming interested in developing and using low-cost air quality sensors, it is important to standardize the procedures used to evaluate their performance. The information discussed herein provides a roadmap for entities who are interested in characterizing air quality sensors in a rigorous, systematic and reproducible manner.
Matula, Svatopluk; Báťková, Kamila; Legese, Wossenu Lemma
2016-11-15
Non-destructive soil water content determination is a fundamental component for many agricultural and environmental applications. The accuracy and costs of the sensors define the measurement scheme and the ability to fit the natural heterogeneous conditions. The aim of this study was to evaluate five commercially available and relatively cheap sensors usually grouped with impedance and FDR sensors. ThetaProbe ML2x (impedance) and ECH₂O EC-10, ECH₂O EC-20, ECH₂O EC-5, and ECH₂O TE (all FDR) were tested on silica sand and loess of defined characteristics under controlled laboratory conditions. The calibrations were carried out in nine consecutive soil water contents from dry to saturated conditions (pure water and saline water). The gravimetric method was used as a reference method for the statistical evaluation (ANOVA with significance level 0.05). Generally, the results showed that our own calibrations led to more accurate soil moisture estimates. Variance component analysis arranged the factors contributing to the total variation as follows: calibration (contributed 42%), sensor type (contributed 29%), material (contributed 18%), and dry bulk density (contributed 11%). All the tested sensors performed very well within the whole range of water content, especially the sensors ECH₂O EC-5 and ECH₂O TE, which also performed surprisingly well in saline conditions.
Matula, Svatopluk; Báťková, Kamila; Legese, Wossenu Lemma
2016-01-01
Non-destructive soil water content determination is a fundamental component for many agricultural and environmental applications. The accuracy and costs of the sensors define the measurement scheme and the ability to fit the natural heterogeneous conditions. The aim of this study was to evaluate five commercially available and relatively cheap sensors usually grouped with impedance and FDR sensors. ThetaProbe ML2x (impedance) and ECH2O EC-10, ECH2O EC-20, ECH2O EC-5, and ECH2O TE (all FDR) were tested on silica sand and loess of defined characteristics under controlled laboratory conditions. The calibrations were carried out in nine consecutive soil water contents from dry to saturated conditions (pure water and saline water). The gravimetric method was used as a reference method for the statistical evaluation (ANOVA with significance level 0.05). Generally, the results showed that our own calibrations led to more accurate soil moisture estimates. Variance component analysis arranged the factors contributing to the total variation as follows: calibration (contributed 42%), sensor type (contributed 29%), material (contributed 18%), and dry bulk density (contributed 11%). All the tested sensors performed very well within the whole range of water content, especially the sensors ECH2O EC-5 and ECH2O TE, which also performed surprisingly well in saline conditions. PMID:27854263
Suliman, Huda S; Fecura, Stephen E; Baskin, Jonathan; Kalns, John E
2011-06-01
Heat and moisture exchangers (HMEs) are used for airway humidification in mechanically ventilated patients and have been evaluated only under hospital conditions. U.S. Air Force aeromedical evacuation transports are performed under rugged conditions further complicated by the cold and dry environment in military aircrafts, and HMEs are used to provide airway humidification for patients. This study evaluated 10 commercial HMEs using a test system that simulated aeromedical evacuation conditions. Although the American National Standards Institute recommends inspired air to be at an absolute humidity value of > or = 30 mg/L for mechanically ventilated patients, the highest absolute humidity by any HME was approximately 20 mg/L. Although none of the HMEs were able to maintain a temperature high enough to achieve the humidity standard of the American National Standards Institute, the clinical significance of this standard may be less important than the relative humidity maintained in the respired air, especially on evacuation flights of short duration.
Evaluation of fuel preparation systems for lean premixing-prevaporizing combustors
NASA Technical Reports Server (NTRS)
Dodds, W. J.; Ekstedt, E. E.
1985-01-01
A series of experiments was carried out in order to produce design data for a premixing prevaporizing fuel-air mixture preparation system for aircraft gas turbine engine combustors. The fuel-air mixture uniformity of four different system design concepts was evaluated over a range of conditions representing the cruise operation of a modern commercial turbofan engine. Operating conditions including pressure, temperature, fuel-to-air ratio, and velocity, exhibited no clear effect on mixture uniformity of systems using pressure-atomizing fuel nozzles and large-scale mixing devices. However, the performance of systems using atomizing fuel nozzles and large-scale mixing devices was found to be sensitive to operating conditions. Variations in system design variables were also evaluated and correlated. Mixing uniformity was found to improve with system length, pressure drop, and the number of fuel injection points per unit area. A premixing system capable of providing mixing uniformity to within 15 percent over a typical range of cruise operating conditions is demonstrated.
Adam, Garret; Wang, Kevin; Demaree, Christopher J.; Jiang, Jenny S.; Cheung, Mathew; Bechara, Carlos F.
2018-01-01
Thoracic outlet syndrome (TOS) is a neurovascular condition involving the upper extremity, which is known to occur in individuals who perform chronic repetitive upper extremity activities. We prospectively evaluate the incidence of TOS in high-performance musicians who played bowed string musicians. Sixty-four high-performance string instrument musicians from orchestras and professional musical bands were included in the study. Fifty-two healthy volunteers formed an age-matched control group. Bilateral upper extremity duplex scanning for subclavian vessel compression was performed in all subjects. Provocative maneuvers including Elevated Arm Stress Test (EAST) and Upper Limb Tension Test (ULTT) were performed. Abnormal ultrasound finding is defined by greater than 50% subclavian vessel compression with arm abduction, diminished venous waveforms, or arterial photoplethysmography (PPG) tracing with arm abduction. Bowed string instruments performed by musicians in our study included violin (41%), viola (33%), and cello (27%). Positive EAST or ULTT test in the musician group and control group were 44%, and 3%, respectively (p = 0.03). Abnormal ultrasound scan with vascular compression was detected in 69% of musicians, in contrast to 15% of control subjects (p = 0.03). TOS is a common phenomenon among high-performance bowed string instrumentalists. Musicians who perform bowed string instruments should be aware of this condition and its associated musculoskeletal symptoms. PMID:29370085
NASA Astrophysics Data System (ADS)
Acero, Juan A.; Arrizabalaga, Jon
2018-01-01
Urban areas are known to modify meteorological variables producing important differences in small spatial scales (i.e. microscale). These affect human thermal comfort conditions and the dispersion of pollutants, especially those emitted inside the urban area, which finally influence quality of life and the use of public open spaces. In this study, the diurnal evolution of meteorological variables measured in four urban spaces is compared with the results provided by ENVI-met (v 4.0). Measurements were carried out during 3 days with different meteorological conditions in Bilbao in the north of the Iberian Peninsula. The evaluation of the model accuracy (i.e. the degree to which modelled values approach measured values) was carried out with several quantitative difference metrics. The results for air temperature and humidity show a good agreement of measured and modelled values independently of the regional meteorological conditions. However, in the case of mean radiant temperature and wind speed, relevant differences are encountered highlighting the limitation of the model to estimate these meteorological variables precisely during diurnal cycles, in the considered evaluation conditions (sites and weather).
Yin, L; Song, X F; Qu, S F; Huang, T; Mei, J P; Yang, Z Y; Li, J
2006-11-01
This paper reports on the performance evaluation of a dental handpiece in simulation of clinical finishing using a novel two-degrees-of-freedom (2DOF) in vitro apparatus. The instrumented apparatus consisted of a two-dimensional computer-controlled coordinate worktable carrying a dental handpiece, a piezoelectric force dynamometer, and a high-speed data acquisition and signal conditioning system for simulating the clinical operations and monitoring the dental finishing processes. The performance of the dental handpiece was experimentally evaluated with respect to rotational speed, torque, and specific finishing energy under the applied clinical finishing conditions. The results show that the rotational speeds of the dental handpiece decreased by increasing either the depth of cut or the feed rate at a constant clinically applied air pressure and water flowrate. They also decreased when increasing both the tangential and normal finishing forces. The specific finishing energy decreased with an increase in either depth of cut or feed rate, while the finishing torque increased as either the depth of cut or the feed rate was increased. Implications of these results were to provide guidance for proper applications of dental handpieces in clinical practice.
The interaction between state and dispositional emotions in decision making: An ERP study.
Wang, Yingying; Gu, Ruolei; Luo, Yue-Jia; Zhou, Chenglin
2017-02-01
In this study, to investigate the influence of incidental emotions on decision making in high-anxious individuals, participants were required to perform a monetary gambling task. Behavioral and electroencephalography responses were recorded to explore the stages of option assessment and outcome evaluation during decision making, respectively. Incidental emotions were elicited by facial expression pictures presented on the background, which included four conditions (control, neutral, fearful, and happy). Results showed smaller feedback-related negativity (FRN) amplitudes in high-anxious participants than low-anxious participants in the control, neutral, and fearful conditions, but not in the happy condition, for small outcomes. The P3 amplitudes were larger in high-anxious participants compared to their counterparts in the fearful and happy conditions, but not in the other conditions. In short, the interaction effects between trait anxiety and facial emotions manifested on the outcome evaluation stage of decision making. Copyright © 2016 Elsevier B.V. All rights reserved.
HuMOVE: a low-invasive wearable monitoring platform in sexual medicine.
Ciuti, Gastone; Nardi, Matteo; Valdastri, Pietro; Menciassi, Arianna; Basile Fasolo, Ciro; Dario, Paolo
2014-10-01
To investigate an accelerometer-based wearable system, named Human Movement (HuMOVE) platform, designed to enable quantitative and continuous measurement of sexual performance with minimal invasiveness and inconvenience for users. Design, implementation, and development of HuMOVE, a wearable platform equipped with an accelerometer sensor for monitoring inertial parameters for sexual performance assessment and diagnosis, were performed. The system enables quantitative measurement of movement parameters during sexual intercourse, meeting the requirements of wearability, data storage, sampling rate, and interfacing methods, which are fundamental for human sexual intercourse performance analysis. HuMOVE was validated through characterization using a controlled experimental test bench and evaluated in a human model during simulated sexual intercourse conditions. HuMOVE demonstrated to be a robust and quantitative monitoring platform and a reliable candidate for sexual performance evaluation and diagnosis. Characterization analysis on the controlled experimental test bench demonstrated an accurate correlation between the HuMOVE system and data from a reference displacement sensor. Experimental tests in the human model during simulated intercourse conditions confirmed the accuracy of the sexual performance evaluation platform and the effectiveness of the selected and derived parameters. The obtained outcomes also established the project expectations in terms of usability and comfort, evidenced by the questionnaires that highlighted the low invasiveness and acceptance of the device. To the best of our knowledge, HuMOVE platform is the first device for human sexual performance analysis compatible with sexual intercourse; the system has the potential to be a helpful tool for physicians to accurately classify sexual disorders, such as premature or delayed ejaculation. Copyright © 2014 Elsevier Inc. All rights reserved.
Hwang, Han-Jeong; Hahne, Janne Mathias; Müller, Klaus-Robert
2017-01-01
There are some practical factors, such as arm position change and donning/doffing, which prevent robust myoelectric control. The objective of this study is to precisely characterize the impacts of the two representative factors on myoelectric controllability in practical control situations, thereby providing useful references that can be potentially used to find better solutions for clinically reliable myoelectric control. To this end, a real-time target acquisition task was performed by fourteen subjects including one individual with congenital upper-limb deficiency, where the impacts of arm position change, donning/doffing and a combination of both factors on control performance was systematically evaluated. The changes in online performance were examined with seven different performance metrics to comprehensively evaluate various aspects of myoelectric controllability. As a result, arm position change significantly affects offline prediction accuracy, but not online control performance due to real-time feedback, thereby showing no significant correlation between offline and online performance. Donning/doffing was still problematic in online control conditions. It was further observed that no benefit was attained when using a control model trained with multiple position data in terms of arm position change, and the degree of electrode shift caused by donning/doffing was not severely associated with the degree of performance loss under practical conditions (around 1 cm electrode shift). Since this study is the first to concurrently investigate the impacts of arm position change and donning/doffing in practical myoelectric control situations, all findings of this study provide new insights into robust myoelectric control with respect to arm position change and donning/doffing.
Hahne, Janne Mathias; Müller, Klaus-Robert
2017-01-01
There are some practical factors, such as arm position change and donning/doffing, which prevent robust myoelectric control. The objective of this study is to precisely characterize the impacts of the two representative factors on myoelectric controllability in practical control situations, thereby providing useful references that can be potentially used to find better solutions for clinically reliable myoelectric control. To this end, a real-time target acquisition task was performed by fourteen subjects including one individual with congenital upper-limb deficiency, where the impacts of arm position change, donning/doffing and a combination of both factors on control performance was systematically evaluated. The changes in online performance were examined with seven different performance metrics to comprehensively evaluate various aspects of myoelectric controllability. As a result, arm position change significantly affects offline prediction accuracy, but not online control performance due to real-time feedback, thereby showing no significant correlation between offline and online performance. Donning/doffing was still problematic in online control conditions. It was further observed that no benefit was attained when using a control model trained with multiple position data in terms of arm position change, and the degree of electrode shift caused by donning/doffing was not severely associated with the degree of performance loss under practical conditions (around 1 cm electrode shift). Since this study is the first to concurrently investigate the impacts of arm position change and donning/doffing in practical myoelectric control situations, all findings of this study provide new insights into robust myoelectric control with respect to arm position change and donning/doffing. PMID:29095846
NASA Astrophysics Data System (ADS)
Welch, K. M.
1981-09-01
The Loyola University site is a student dormitory in New Orleans, Louisiana whose active solar energy system is designed to supply 52% of the hot water demand. The system is equipped with 4590 square feet of flat-plate collectors, a 5000-gallon water tank, auxiliary water supplied at high temperature and pressure from a central heating plant with a gas-fired boiler, and a differential controller that selects from 5 operating modes. System performance data are given, including the solar fraction, solar savings ratio, conventional fuel savings, system performance factor, and system coefficient of performance. The solar fraction is well below the design goal; this is attributed to great fluctuations in demand. Insolation, temperature, operation and solar energy utilization data are also presented. The performance of the collector, storage, and domestic hot water subsystems, the system operating energy, energy savings, and weather conditions are also evaluated. Appended are a system description, performance evaluation techniques and equations, site history, sensor technology, and typical monthly data.
Beck, Joy E; Lipani, Tricia A; Baber, Kari F; Dufton, Lynette; Garber, Judy; Smith, Craig A; Walker, Lynn S
2011-05-01
This study investigated attentional biases for pain and social threat versus neutral stimuli in 54 youth with functional abdominal pain (FAP) and 53 healthy control subjects (ages 10 to 16 years). We assessed attentional bias using a visual probe detection task (PDT) that presented pain and social threat words in comparison to neutral words at conscious (1250 ms) and preconscious (20 ms) presentation rates. We administered the PDT before and after random assignment of participants to a laboratory stressor--failure versus success feedback regarding their performance on a challenging computer game. All analyses controlled for trait anxiety. At the conscious rate of stimulus presentation, FAP patients exhibited preferential attention toward pain compared with neutral stimuli and compared with the control group. FAP patients maintained preferential attention toward conscious pain stimuli after performance feedback in both failure and success conditions. At the preconscious rate of stimulus presentation, FAP patients' attention was neutral at baseline but increased significantly toward pain stimuli after performance feedback in both failure and success conditions. FAP patients' somatic symptoms increased in both failure and success conditions; control youth's somatic symptoms only increased after failure. Regarding social threat, neither FAP nor control youth exhibited attentional bias toward social threat compared with neutral stimuli at baseline, but both FAP and control youth in the failure condition significantly increased attention away from social threat after failure feedback. Results suggest that FAP patients preferentially attend to pain stimuli in conscious awareness. Moreover, performance evaluation may activate their preconscious attention to pain stimuli. Copyright © 2011 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.
Performance of a catalytic reactor at simulated gas turbine combustor operating conditions
NASA Technical Reports Server (NTRS)
Anderson, D. N.; Tacina, R. R.; Mroz, T. S.
1975-01-01
The performance of a catalytic reactor 12 cm in diameter and 17 cm long was evaluated at simulated gas turbine combustor operating conditions using premixed propane and air. Inlet temperatures of 600 and 800 K, pressures of 3 and 6 atm, and reference velocities of 9 to 30 m/s were tested. Data were taken for equivalence ratios as high as 0.43. The operating range was limited on the low-temperature side by very poor efficiency; the minimum exit temperature for good performance ranged from 1400 to 1600 K depending on inlet conditions. As exit temperatures were raised above this minimum, emissions of unburned hydrocarbons decreased, carbon monoxide emissions became generally less than 1 g CO/kg fuel, and nitrogen oxides were less than about 0.1 g NO2/kg fuel.
Development of COPVS for High pressure, In-Space, Cryogenic Fuel Storage
NASA Technical Reports Server (NTRS)
DeLay, Tom; Schneider, Judy; Dyess, Mark; Hastings, Chad; Noorda, Ryan; Noorda, Jared; Patterson, James
2008-01-01
Polymeric composite overwrapped pressure vessels (COPVs) provide an attractive material system to support developing commercial launch business and alternate fuel ventures. However to be able to design with these materials, the mechanical behavior of the materials must be understood with regards to processing, performance, damage tolerance, and environment. For the storage of cryogenic propellants, it is important to evaluate the materials performance and impact damage resistance at cryogenic temperatures in order to minimize weight and to ensure safety and reliability. To evaluate the ultimate performance, various polymeric COPV's have been statically burst tested at cryogenic conditions before and after exposure to irradiation. Materials selected for these COPVs were based on the measured mechanical properties of candidate resin systems and fibers that were also tested at cryogenic conditions before and after exposure to irradiation. The correlation of COPV burst pressures with the constituent material properties has proven to be a valuable screening method for selection of suitable candidate materials with resistance to material degradation due to exposure to temperature and radiation.
Evaluation of Zeolite Permeable Treatment Wall for the Removal of Strontium-90 from Groundwater
NASA Astrophysics Data System (ADS)
Seneca, S. M.; Bronner, C.; Ross, E.; Rabideau, A. J.
2009-05-01
Experimental and modeling studies have been initiated to evaluate the potential performance of a permeable treatment wall comprised of zeolite-rich rock for the removal of strontium-90 from groundwater. Preliminary column studies were performed using a synthetic groundwater referenced to anticipate field conditions, with a focus on quantifying the competitive ion exchange among five cations (Na+, K+, Ca2+, Mg2+, and Sr2+). Variations of the column configurations addressed the effects of particle size and flow rates on removal efficiency. In general, kinetic effects were not significant for the test conditions. Ongoing studies are focused on the comparison of zeolites obtained from two sources: Teague Mineral Products (Adrian, OR) and Bear River Zeolite (Preston, UT), and on the possible influence of native soil that is mixed with treatment wall material during construction. The results of the performance assessment will support the possible deployment of a full scale treatment wall at a Western New York nuclear facility.
Air-to-Water Heat Pumps With Radiant Delivery in Low-Load Homes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Backman, C.; German, A.; Dakin, B.
2013-12-01
Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump (AWHP) systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 tomore » test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).« less
NASA Astrophysics Data System (ADS)
Uysal, Selcuk Can
In this research, MATLAB SimulinkRTM was used to develop a cooled engine model for industrial gas turbines and aero-engines. The model consists of uncooled on-design, mean-line turbomachinery design and a cooled off-design analysis in order to evaluate the engine performance parameters by using operating conditions, polytropic efficiencies, material information and cooling system details. The cooling analysis algorithm involves a 2nd law analysis to calculate losses from the cooling technique applied. The model is used in a sensitivity analysis that evaluates the impacts of variations in metal Biot number, thermal barrier coating Biot number, film cooling effectiveness, internal cooling effectiveness and maximum allowable blade temperature on main engine performance parameters of aero and industrial gas turbine engines. The model is subsequently used to analyze the relative performance impact of employing Anti-Vortex Film Cooling holes (AVH) by means of data obtained for these holes by Detached Eddy Simulation-CFD Techniques that are valid for engine-like turbulence intensity conditions. Cooled blade configurations with AVH and other different external cooling techniques were used in a performance comparison study. (Abstract shortened by ProQuest.).
NASA Technical Reports Server (NTRS)
Litt, Jonathan S.; Guo, Ten-Huei; Sowers, T. Shane; Chicatelli, Amy K.; Fulton, Christopher E.; May, Ryan D.; Owen, A. Karl
2012-01-01
This paper describes the implementation and evaluation of a yaw rate to throttle feedback system designed to replace a damaged rudder. It can act as a Dutch roll damper and as a means to facilitate pilot input for crosswind landings. Enhanced propulsion control modes were implemented to increase responsiveness and thrust level of the engine, which impact flight dynamics and performance. Piloted evaluations were performed to determine the capability of the engines to substitute for the rudder function under emergency conditions. The results showed that this type of implementation is beneficial, but the engines' capability to replace the rudder is limited.
Glass, Stephen M; Ross, Scott E
2015-10-01
Failure to meet minimum performance standards is a leading cause of attrition from basic combat training. A standardized assessment such as the Functional Movement Screen™ (FMS™) could help identify movement behaviors relevant to physical performance in tactical occupations. Previous work has demonstrated only marginal association between FMS™ tests and performance outcomes, but adding a load challenge to this movement assessment may help highlight performance-limiting behaviors. The purposes of this investigation were to quantify the effect of load on FMS™ tests and determine the extent to which performance outcomes could be predicted using scores from both loaded and unloaded FMS™ conditions. Crossover Trial. Thirteen female and six male recreationally active college students (21 ± 1.37 years, 168 ± 9.8 cm, 66 ± 12.25 kg) completed the FMS™ under (1) a control condition (FMS™C), and (2) an 18.10kg weight vest condition (FMS™W). Balance was assessed using a force plate in double-legged stance and tactical physical performance was evaluated via completion times in a battery of field tests. For each condition, penalized regression was used to select models from the seven FMS™ component tests to predict balance and performance outcomes. Data were collected during a single session lasting approximately three hours per participant. For balance, significant predictors were identified from both conditions but primarily predicted poorer balance with increasing FMS™ scores. For tactical performance, models were retained almost exclusively from FMS™W and generally predicted better performance with higher item scores. The current results suggest that FMS™ screening with an external load could help predict performance relevant to tactical occupations. Sports medicine and fitness professionals interested in performance outcomes may consider assessing movement behaviors under a load. 3.
NASA Technical Reports Server (NTRS)
Nelson, D. P.
1981-01-01
Tabulated data from wind tunnel tests conducted to evaluate the aerodynamic performance of an advanced coannular exhaust nozzle for a future supersonic propulsion system are presented. Tests were conducted with two test configurations: (1) a short flap mechanism for fan stream control with an isentropic contoured flow splitter, and (2) an iris fan nozzle with a conical flow splitter. Both designs feature a translating primary plug and an auxiliary inlet ejector. Tests were conducted at takeoff and simulated cruise conditions. Data were acquired at Mach numbers of 0, 0.36, 0.9, and 2.0 for a wide range of nozzle operating conditions. At simulated supersonic cruise, both configurations demonstrated good performance, comparable to levels assumed in earlier advanced supersonic propulsion studies. However, at subsonic cruise, both configurations exhibited performance that was 6 to 7.5 percent less than the study assumptions. At takeoff conditions, the iris configuration performance approached the assumed levels, while the short flap design was 4 to 6 percent less. Data are provided through test run 25.
NASA Technical Reports Server (NTRS)
Nelson, D. P.
1980-01-01
Wind tunnel tests were conducted to evaluate the aerodynamic performance of a coannular exhaust nozzle for a proposed variable stream control supersonic propulsion system. Tests were conducted with two simulated configurations differing primarily in the fan duct flowpaths: a short flap mechanism for fan stream control with an isentropic contoured flow splitter, and an iris fan nozzle with a conical flow splitter. Both designs feature a translating primary plug and an auxiliary inlet ejector. Tests were conducted at takeoff and simulated cruise conditions. Data were acquired at Mach numbers of 0, 0.36, 0.9, and 2.0 for a wide range of nozzle operating conditions. At simulated supersonic cruise, both configurations demonstrated good performance, comparable to levels assumed in earlier advanced supersonic propulsion studies. However, at subsonic cruise, both configurations exhibited performance that was 6 to 7.5 percent less than the study assumptions. At take off conditions, the iris configuration performance approached the assumed levels, while the short flap design was 4 to 6 percent less.
Empirical evaluation of H.265/HEVC-based dynamic adaptive video streaming over HTTP (HEVC-DASH)
NASA Astrophysics Data System (ADS)
Irondi, Iheanyi; Wang, Qi; Grecos, Christos
2014-05-01
Real-time HTTP streaming has gained global popularity for delivering video content over Internet. In particular, the recent MPEG-DASH (Dynamic Adaptive Streaming over HTTP) standard enables on-demand, live, and adaptive Internet streaming in response to network bandwidth fluctuations. Meanwhile, emerging is the new-generation video coding standard, H.265/HEVC (High Efficiency Video Coding) promises to reduce the bandwidth requirement by 50% at the same video quality when compared with the current H.264/AVC standard. However, little existing work has addressed the integration of the DASH and HEVC standards, let alone empirical performance evaluation of such systems. This paper presents an experimental HEVC-DASH system, which is a pull-based adaptive streaming solution that delivers HEVC-coded video content through conventional HTTP servers where the client switches to its desired quality, resolution or bitrate based on the available network bandwidth. Previous studies in DASH have focused on H.264/AVC, whereas we present an empirical evaluation of the HEVC-DASH system by implementing a real-world test bed, which consists of an Apache HTTP Server with GPAC, an MP4Client (GPAC) with open HEVC-based DASH client and a NETEM box in the middle emulating different network conditions. We investigate and analyze the performance of HEVC-DASH by exploring the impact of various network conditions such as packet loss, bandwidth and delay on video quality. Furthermore, we compare the Intra and Random Access profiles of HEVC coding with the Intra profile of H.264/AVC when the correspondingly encoded video is streamed with DASH. Finally, we explore the correlation among the quality metrics and network conditions, and empirically establish under which conditions the different codecs can provide satisfactory performance.
Ahmed, Egbal Mohammed; Abaas, Osama; Ahmed, Mohammed; Ismail, Mohd Rodzi
2011-01-01
This study was conducted in Date Palm Technology Company Limited, Shambat, Khartoum State. To evaluate performance of three types of evaporative cooling pads for greenhouses (celdek pads, straw pads and sliced wood pads), as compared to the conditions outside the greenhouses (control), for pads. Performance evaluation includes environmental parameters (temperature and relative humidity at 8 am, 1 pm and 6 pm) and crop parameters (length and stem diameter, leaves number and width, fruit length and diameter, fruit weight and dry matter and yield). The results obtained for the temperature at 8 am showed that there was no significant difference (0.05) inside the greenhouses, while a high significant difference between the conditions inside and outside of the greenhouses was found. Significant differences were found at 1 pm and 6 pm between all treatments as compared to the conditions outside the greenhouses, and the results obtained for relative humidity showed high significant differences at 8 am and 1 pm inside the greenhouses and between inside and outside the greenhouse, respectively, while there was no significant difference at 6 pm inside the greenhouses and between inside and outside the greenhouses. On the other hand, the results obtained for crop parameters showed that there were significant differences between all parameters inside the greenhouses and outside the greenhouses; however, the greenhouses with sliced wood pads gave the highest yield and the greenhouses with straw pads gave the least and conditions outside gave the lowest. This study indicated that the sliced wood pads are better than the other evaporative cooling pads.
Zimmer-Faust, Amity G; Ambrose, Richard F; Tamburri, Mario N
2014-01-01
With the maturation and certification of several ballast water management systems that employ chlorine as biocide to prevent the spread of invasive species, there is a clear need for accurate and reliable total residual oxidants (TRO) technology to monitor treatment dose and assure the environmental safety of treated water discharged from ships. In this study, instruments used to measure TRO in wastewater and drinking water applications were evaluated for their performance in scenarios mimicking a ballast water treatment application (e.g., diverse hold times, temperatures, and salinities). Parameters chosen for testing these technologies in the past do not reflect conditions expected during ballast water treatment. Salinity, temperature, and oxidant concentration all influenced the response of amperometric sensors. Oxidation reduction potential (ORP) sensors performed more consistently than amperometric sensors under different conditions but it may be difficult to correlate ORP and TRO measurements for the multitude of biogeochemical conditions found naturally in ballast water. N,N-diethyl-p-phenylenediamine (DPD) analyzers and amperometric sensors were also tested under intermittent sampling conditions mimicking a ballasting scenario, with cyclical dosage and discharge operations. When sampling was intermittent, amperometric sensors required excessive response and conditioning times, whereas DPD analyzers provided reasonable estimates of TRO under the ballasting scenario.
Effect of Cognitive Demand on Functional Visual Field Performance in Senior Drivers with Glaucoma
Gangeddula, Viswa; Ranchet, Maud; Akinwuntan, Abiodun E.; Bollinger, Kathryn; Devos, Hannes
2017-01-01
Purpose: To investigate the effect of cognitive demand on functional visual field performance in drivers with glaucoma. Method: This study included 20 drivers with open-angle glaucoma and 13 age- and sex-matched controls. Visual field performance was evaluated under different degrees of cognitive demand: a static visual field condition (C1), dynamic visual field condition (C2), and dynamic visual field condition with active driving (C3) using an interactive, desktop driving simulator. The number of correct responses (accuracy) and response times on the visual field task were compared between groups and between conditions using Kruskal–Wallis tests. General linear models were employed to compare cognitive workload, recorded in real-time through pupillometry, between groups and conditions. Results: Adding cognitive demand (C2 and C3) to the static visual field test (C1) adversely affected accuracy and response times, in both groups (p < 0.05). However, drivers with glaucoma performed worse than did control drivers when the static condition changed to a dynamic condition [C2 vs. C1 accuracy; glaucoma: median difference (Q1–Q3) 3 (2–6.50) vs. controls: 2 (0.50–2.50); p = 0.05] and to a dynamic condition with active driving [C3 vs. C1 accuracy; glaucoma: 2 (2–6) vs. controls: 1 (0.50–2); p = 0.02]. Overall, drivers with glaucoma exhibited greater cognitive workload than controls (p = 0.02). Conclusion: Cognitive demand disproportionately affects functional visual field performance in drivers with glaucoma. Our results may inform the development of a performance-based visual field test for drivers with glaucoma. PMID:28912712
Wang, Lei; Zheng, Jiehui; Meng, Liang
2017-04-01
Although many studies have investigated the relationship between the amount of effort invested in a certain task and one's attitude towards the subsequent reward, whether exerted effort would impact one's expectation and evaluation of performance feedback itself still remains to be examined. In the present study, two types of calculation tasks that varied in the required effort were adopted, and we resorted to electroencephalography to probe the temporal dynamics of how exerted effort would affect one's anticipation and evaluation of performance feedback. In the high-effort condition, a more salient stimulus-preceding negativity was detected during the anticipation stage, which was accompanied with a more salient FRN/P300 complex (a more positive P300 and a less negative feedback-related negativity) in response to positive outcomes in the evaluation stage. These results suggested that when more effort was invested, an enhanced anticipatory attention would be paid toward one's task performance feedback and that positive outcomes would be subjectively valued to a greater extent.
Cheng, Shu Hui; Sun, Zih-Jie; Lee, I Hui; Shih, Chi-Chen; Chen, Kao Chin; Lin, Shih-Hsien; Lu, Feng-Hwa; Yang, Yi-Ching; Yang, Yen Kuang
2015-01-01
Premenstrual syndrome (PMS) is a common condition, and for 5% of women, the influence is so severe as to interfere with their mental health, interpersonal relationships, or studies. Severe PMS may result in decreased occupational productivity. The aim of this study was to investigate the influence of perception of PMS on evaluation of work performance. A total of 1971 incoming female university students were recruited in September 2009. A simulated clinical scenario was used, with a test battery including measurement of psychological symptoms and the Chinese Premenstrual Symptom Questionnaire. When evaluating employee performance in the simulated scenario, 1565 (79.4%) students neglected the impact of PMS, while 136 (6.9%) students considered it. Multivariate logistic regression showed that perception of daily function impairment due to PMS and frequency of measuring body weight were significantly associated with consideration of the influence of PMS on evaluation of work performance. It is important to increase the awareness of functional impairments related to severe PMS.
Janssen, Christian P; Brumby, Duncan P; Dowell, John; Chater, Nick; Howes, Andrew
2011-01-01
We report the results of a dual-task study in which participants performed a tracking and typing task under various experimental conditions. An objective payoff function was used to provide explicit feedback on how participants should trade off performance between the tasks. Results show that participants' dual-task interleaving strategy was sensitive to changes in the difficulty of the tracking task and resulted in differences in overall task performance. To test the hypothesis that people select strategies that maximize payoff, a Cognitively Bounded Rational Analysis model was developed. This analysis evaluated a variety of dual-task interleaving strategies to identify the optimal strategy for maximizing payoff in each condition. The model predicts that the region of optimum performance is different between experimental conditions. The correspondence between human data and the prediction of the optimal strategy is found to be remarkably high across a number of performance measures. This suggests that participants were honing their behavior to maximize payoff. Limitations are discussed. Copyright © 2011 Cognitive Science Society, Inc.
On predicting monitoring system effectiveness
NASA Astrophysics Data System (ADS)
Cappello, Carlo; Sigurdardottir, Dorotea; Glisic, Branko; Zonta, Daniele; Pozzi, Matteo
2015-03-01
While the objective of structural design is to achieve stability with an appropriate level of reliability, the design of systems for structural health monitoring is performed to identify a configuration that enables acquisition of data with an appropriate level of accuracy in order to understand the performance of a structure or its condition state. However, a rational standardized approach for monitoring system design is not fully available. Hence, when engineers design a monitoring system, their approach is often heuristic with performance evaluation based on experience, rather than on quantitative analysis. In this contribution, we propose a probabilistic model for the estimation of monitoring system effectiveness based on information available in prior condition, i.e. before acquiring empirical data. The presented model is developed considering the analogy between structural design and monitoring system design. We assume that the effectiveness can be evaluated based on the prediction of the posterior variance or covariance matrix of the state parameters, which we assume to be defined in a continuous space. Since the empirical measurements are not available in prior condition, the estimation of the posterior variance or covariance matrix is performed considering the measurements as a stochastic variable. Moreover, the model takes into account the effects of nuisance parameters, which are stochastic parameters that affect the observations but cannot be estimated using monitoring data. Finally, we present an application of the proposed model to a real structure. The results show how the model enables engineers to predict whether a sensor configuration satisfies the required performance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Xiaobing; Malhotra, Mini; Xiong, Zeyu
High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects have been competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This paper highlights the findings of a case study of one of the ARRA-funded GSHP demonstration projects, a distributed GSHP system for providing all the space conditioning, outdoor air ventilation, and 100% domestic hot water tomore » the Wilders Grove Solid Waste Service Center of City of Raleigh, North Carolina. This case study is based on the analysis of measured performance data, construction costs, and simulations of the energy consumption of conventional central heating, ventilation, and air-conditioning (HVAC) systems providing the same level of space conditioning and outdoor air ventilation as the demonstrated GSHP system. The evaluated performance metrics include the energy efficiency of the heat pump equipment and the overall GSHP system, pumping performance, energy savings, carbon emission reductions, and cost-effectiveness of the GSHP system compared with conventional HVAC systems. This case study also identified opportunities for reducing uncertainties in the performance evaluation and improving the operational efficiency of the demonstrated GSHP system.« less
Tactile learning and the individual evaluation of the reward in honey bees (Apis mellifera L.).
Scheiner, R; Erber, J; Page, R E
1999-07-01
Using the proboscis extension response we conditioned pollen and nectar foragers of the honey bee (Apis mellifera L.) to tactile patterns under laboratory conditions. Pollen foragers demonstrated better acquisition, extinction, and reversal learning than nectar foragers. We tested whether the known differences in response thresholds to sucrose between pollen and nectar foragers could explain the observed differences in learning and found that nectar foragers with low response thresholds performed better during acquisition and extinction than ones with higher thresholds. Conditioning pollen and nectar foragers with similar response thresholds did not yield differences in their learning performance. These results suggest that differences in the learning performance of pollen and nectar foragers are a consequence of differences in their perception of sucrose. Furthermore, we analysed the effect which the perception of sucrose reward has on associative learning. Nectar foragers with uniform low response thresholds were conditioned using varying concentrations of sucrose. We found significant positive correlations between the concentrations of the sucrose rewards and the performance during acquisition and extinction. The results are summarised in a model which describes the relationships between learning performance, response threshold to sucrose, concentration of sucrose and the number of rewards.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Revel, G. M.; Castellini, P.; Chiariotti, P.
2010-05-28
The present work deals with the analysis of problems and potentials of laser vibrometer measurements inside helicopter cabins in running conditions. The paper describes the results of a systematic measurement campaign performed on an Agusta A109MKII mock-up. The aim is to evaluate the applicability of Scanning Laser Doppler Vibrometer (SLDV) for tests in simulated flying conditions and to understand how performances of the technique are affected when the laser head is placed inside the cabin, thus being subjected to interfering inputs. Firstly a brief description of the performed test cases and the used measuring set-ups are given. Comparative tests betweenmore » SLDV and accelerometers are presented, analyzing the achievable performances for the specific application. Results obtained measuring with SLDV placed inside the helicopter cabin during operative excitation conditions are compared with those performed with the laser lying outside the mock-up, these last being considered as 'reference measurements'. Finally, in order to give an estimate of the uncertainty level on measured signals, a study linking the admitted percentage of noise content on vibrometer signals due to laser head vibration levels will be introduced.« less
DOT National Transportation Integrated Search
1971-03-01
An analysis was made of methods for measuring vehicle occupant motion during crash or impact conditions. The purpose of the measurements is to evaluate restraint performance using human, anthropometric dummy, or animal occupants. A detailed Fourier f...
Remote sensing of multimodal transportation systems : research brief.
DOT National Transportation Integrated Search
2016-09-01
Remote Sensing of Multimodal Transportation Systems : Rapid condition monitoring and performance evaluations of the vast and vulnerable transportation infrastructure has been elusive. The framework and models developed in this research will enable th...
Fixed automated spray technology.
DOT National Transportation Integrated Search
2011-04-19
This research project evaluated the construction and performance of Boschungs Fixed Automated : Spray Technology (FAST) system. The FAST system automatically sprays de-icing material on : the bridge when icing conditions are about to occur. The FA...
In-reactor oxidation of zircaloy-4 under low water vapor pressures
NASA Astrophysics Data System (ADS)
Luscher, Walter G.; Senor, David J.; Clayton, Kevin K.; Longhurst, Glen R.
2015-01-01
Complementary in- and ex-reactor oxidation tests have been performed to evaluate the oxidation and hydrogen absorption performance of Zircaloy-4 (Zr-4) under relatively low partial pressures (300 and 1000 Pa) of water vapor at specified test temperatures (330 and 370 °C). Data from these tests will be used to support the fabrication of components intended for isotope-producing targets and provide information regarding the temperature and pressure dependence of oxidation and hydrogen absorption of Zr-4 over the specified range of test conditions. Comparisons between in- and ex-reactor test results were performed to evaluate the influence of irradiation.
NASA Technical Reports Server (NTRS)
1975-01-01
A program was conducted which included the design of a set of simplified simulation tasks, design of apparatus and breadboard TV equipment for task performance, and the implementation of a number of simulation tests. Performance measurements were made under controlled conditions and the results analyzed to permit evaluation of the relative merits (effectivity) of various TV systems. Burden factors were subsequently generated for each TV system to permit tradeoff evaluation of system characteristics against performance. For the general remote operation mission, the 2-view system is recommended. This system is characterized and the corresponding equipment specifications were generated.
Improving pilot mental workload evaluation with combined measures.
Wanyan, Xiaoru; Zhuang, Damin; Zhang, Huan
2014-01-01
Behavioral performance, subjective assessment based on NASA Task Load Index (NASA-TLX), as well as physiological measures indexed by electrocardiograph (ECG), event-related potential (ERP), and eye tracking data were used to assess the mental workload (MW) related to flight tasks. Flight simulation tasks were carried out by 12 healthy participants under different MW conditions. The MW conditions were manipulated by setting the quantity of flight indicators presented on the head-up display (HUD) in the cruise phase. In this experiment, the behavioral performance and NASA-TLX could reflect the changes of MW ideally. For physiological measures, the indices of heart rate variability (HRV), P3a, pupil diameter and eyelid opening were verified to be sensitive to MW changes. Our findings can be applied to the comprehensive evaluation of MW during flight tasks and the further quantitative classification.
Randolph, John J; Randolph, Jennifer S; Wishart, Heather A
2017-02-01
Individuals with multiple sclerosis (MS) often report cognitive dysfunction, although neuropsychological evaluation findings may not correlate with subjective concerns. One factor that may explain this lack of correspondence is the controlled testing environment, which differs from busier settings where cognitive lapses are noted to occur. This study used a novel environmental manipulation to determine whether individuals with MS who report cognitive dysfunction are more vulnerable to the effects of auditory distraction during neuropsychological testing. Twenty-four individuals with clinically definite MS or clinically isolated syndrome were administered a cognitive battery during two counterbalanced auditory conditions: quiet/standard condition, and distraction condition with random office background noise. Participants were divided into high versus low cognitive complaint groups using a median split analysis of Perceived Deficits Questionnaire responses. Participants with more cognitive complaints showed a decrement in performance on the oral Symbol Digit Modalities Test during the distraction condition while those with fewer cognitive complaints demonstrated stable performance across conditions. These findings remained significant after controlling for education, premorbid intellect, fatigue, and depressed mood. These results suggest that individuals with MS with more cognitive complaints are vulnerable to environmental distraction, particularly regarding processing speed. Incorporating random environmental noise or other distraction conditions during selected measures may enhance the ecological validity of neuropsychological evaluation results in MS. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Analysis on burnup step effect for evaluating reactor criticality and fuel breeding ratio
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saputra, Geby; Purnama, Aditya Rizki; Permana, Sidik
Criticality condition of the reactors is one of the important factors for evaluating reactor operation and nuclear fuel breeding ratio is another factor to show nuclear fuel sustainability. This study analyzes the effect of burnup steps and cycle operation step for evaluating the criticality condition of the reactor as well as the performance of nuclear fuel breeding or breeding ratio (BR). Burnup step is performed based on a day step analysis which is varied from 10 days up to 800 days and for cycle operation from 1 cycle up to 8 cycles reactor operations. In addition, calculation efficiency based onmore » the variation of computer processors to run the analysis in term of time (time efficiency in the calculation) have been also investigated. Optimization method for reactor design analysis which is used a large fast breeder reactor type as a reference case was performed by adopting an established reactor design code of JOINT-FR. The results show a criticality condition becomes higher for smaller burnup step (day) and for breeding ratio becomes less for smaller burnup step (day). Some nuclides contribute to make better criticality when smaller burnup step due to individul nuclide half-live. Calculation time for different burnup step shows a correlation with the time consuming requirement for more details step calculation, although the consuming time is not directly equivalent with the how many time the burnup time step is divided.« less
Acute Effects of the Elevation Training Mask on Strength Performance in Recreational Weight lifters.
Jagim, Andrew R; Dominy, Trevor A; Camic, Clayton L; Wright, Glenn; Doberstein, Scott; Jones, Margaret T; Oliver, Jonathan M
2018-02-01
Jagim, AR, Dominy, TA, Camic, CL, Wright, G, Doberstein, S, Jones, MT, and Oliver, JM. Acute effects of the elevation training mask on strength performance in recreational weightlifters. J Strength Cond Res 32(2): 482-489, 2018-The Elevation Training Mask 2.0 (ETM) is a novel device that purportedly simulates altitude training. The purpose of this study was to investigate the acute effects of the ETM on resistance exercise performance, metabolic stress markers, and ratings of mental fatigue. Twenty male recreational weight lifters completed 2 training sessions of back squat and bench press (6 sets of 10 repetitions at 85% of 5-repetition maximum and seventh set to failure) as well as a maximal effort sprint test (18% body mass) with the mask (ETM) and without the mask (NM). Training evaluation included baseline and postexercise blood lactate and oxygen saturation measures. Performance evaluation included peak and average velocity bar velocity, total volume load, total work, total repetitions completed, and sprint performance. Adverse side effects were reported in 12% (n = 3) of participants, which included feelings of light headedness, anxiety, and discomfort. No differences were found in repetitions or total workload in back squat (p = 0.07) or bench press (p = 0.08) between conditions. A lower peak velocity was identified during the back squat, bench press, and sprint test in the ETM condition (p = 0.04). Blood lactate values were lower after bench press and sprint during the ETM condition (p < 0.001). Significantly lower ratings of alertness and focus for task were found after squat, bench press, and sprint test in the ETM condition compared with the NM condition (p < 0.001). Wearing the ETM during bouts of resistance training did not hinder the ability to achieve desired training volumes during the resistance training session. However, wearing the ETM does seem to attenuate the ability to maintain working velocity during training bouts and negatively influence ratings of alertness and focus for task.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-23
... PHA to four key areas of a PHA's operations: (1) The physical condition of the PHA's properties; (2... and to require PHAs to be scored on performance based on evaluation of four indicators: physical... changes proposed to each of the four current PHAS indicators are as follows: Physical. The physical...
ERIC Educational Resources Information Center
Wooley, John F.
In the operation of vacuum filters and belt filters, it is desirable to evaluate the performance of different types of filter media and conditioning processes. The filter leaf test, which is used to evaluate these items, is described. Designed for individuals who have completed National Pollutant Discharge Elimination System (NPDES) level 1…
DOT National Transportation Integrated Search
1987-01-01
This interim report presents the results after 5 years of a study undertaken to evaluate multiple layer polymer concrete overlays over a 10-year period. The report indicates that an overlay of low permeability and high skid resistance can be successf...
USDA-ARS?s Scientific Manuscript database
The objective of this study was to evaluate the effects of moisture addition at the gin stand feeder conditioning hopper and/or the battery condenser slide on gin performance and Western cotton fiber quality and textile processing. The test treatments included no moisture addition, feeder hopper hum...
Evaluating growth performance of young stands
A. L. Roe; R. E. Benson
1966-01-01
A simple procedure for evaluating the diameter growth of young stands in relation to potential growth is described. A comparison technique is developed which contrasts relative diameter of crop trees to the relative diameter growth of the last decade to show the condition and trend of growth in the stand. The method is objective, easy to use, and has several...
2017-04-21
determine whether a service member (SM) with medical condition(s) is fit or unfit to perform his or her assigned duties. The results of MEB exams are...SM might diminish the severity of their symptoms out of fear of being discharged. Alternatively, SM might be influenced to exaggerate his or her
Health Monitoring System for Composite Structures
NASA Technical Reports Server (NTRS)
Tang, S. S.; Riccardella, P. C.; Andrews, R. J.; Grady, J. E.; Mucciaradi, A. N.
1996-01-01
An automated system was developed to monitor the health status of composites. It uses the vibration characteristics of composites to identify a component's damage condition. The vibration responses are characterized by a set of signal features defined in the time, frequency and spatial domains. The identification of these changes in the vibration characteristics corresponding to different health conditions was performed using pattern recognition principles. This allows efficient data reduction and interpretation of vast amounts of information. Test components were manufactured from isogrid panels to evaluate performance of the monitoring system. The components were damaged by impact to simulate different health conditions. Free vibration response was induced by a tap test on the test components. The monitoring system was trained using these free vibration responses to identify three different health conditions. They are undamaged vs. damaged, damage location and damage zone size. High reliability in identifying the correct component health condition was achieved by the monitoring system.
Implications of Transitioning from De Facto to Engineered Water Reuse for Power Plant Cooling.
Barker, Zachary A; Stillwell, Ashlynn S
2016-05-17
Thermoelectric power plants demand large quantities of cooling water, and can use alternative sources like treated wastewater (reclaimed water); however, such alternatives generate many uncertainties. De facto water reuse, or the incidental presence of wastewater effluent in a water source, is common at power plants, representing baseline conditions. In many cases, power plants would retrofit open-loop systems to cooling towers to use reclaimed water. To evaluate the feasibility of reclaimed water use, we compared hydrologic and economic conditions at power plants under three scenarios: quantified de facto reuse, de facto reuse with cooling tower retrofits, and modeled engineered reuse conditions. We created a genetic algorithm to estimate costs and model optimal conditions. To assess power plant performance, we evaluated reliability metrics for thermal variances and generation capacity loss as a function of water temperature. Applying our analysis to the greater Chicago area, we observed high de facto reuse for some power plants and substantial costs for retrofitting to use reclaimed water. Conversely, the gains in reliability and performance through engineered reuse with cooling towers outweighed the energy investment in reclaimed water pumping. Our analysis yields quantitative results of reclaimed water feasibility and can inform sustainable management of water and energy.
Evaluation of Brushing as a Lunar Dust Mitigation Strategy for Thermal Control Surfaces
NASA Technical Reports Server (NTRS)
Gaier, James R.; Journey, Khrissaundra; Christopher, Steven; Davis, Shanon
2011-01-01
Evaluation of brushing to remove lunar simulant dust from thermal control surfaces is described. First, strip brushes made with nylon, PTFE, or Thunderon (Nihon Sanmo Dyeing Company Ltd.) bristles were used to remove JSC-1AF dust from AZ93 thermal control paint or aluminized FEP (AlFEP) thermal control surface under ambient laboratory conditions. Nylon and PTFE bristles removed a promising amount of dust from AZ93, and nylon and Thunderon bristles from AlFEP. But when these were tested under simulated lunar conditions in the lunar dust adhesion bell jar (LDAB), they were not effective. In a third effort, seven brushes made up of three different materials, two different geometries, and different bristle lengths and thicknesses were tested under laboratory conditions against AZ93 and AlFEP. Two of these brushes, the Zephyr fiberglass fingerprint brush and the Escoda nylon fan brush, removed over 90 percent of the dust, and so were tested in the fourth effort in the LDAB. They also performed well under these conditions recovering 80 percent or more of the original thermal performance (solar absorptance/thermal emittance) of both AZ93 and AgFEP after 20 strokes, and 90 or more percent after 200 strokes
Evaluation of Brushing as a Lunar Dust Mitigation Strategy for Thermal Control Surfaces
NASA Technical Reports Server (NTRS)
Gaier, James R.; Journey, Hhrissaundra; Christopher, Steven; Davis, Shanon
2011-01-01
Evaluation of brushing to remove lunar simulant dust from thermal control surfaces is described. First, strip brushes made with nylon, PTFE, or Thunderon bristles were used to remove JSC-1AF dust from AZ93 thermal control paint or aluminized FEP (AlFEP) thermal control surface under ambient laboratory conditions. Nylon and PTFE bristles removed a promising amount of dust from AZ93, and nylon and Thunderon bristles from AlFEP. But when these were tested under simulated lunar conditions in the lunar dust adhesion bell jar (LDAB), they were not effective. In a third effort, seven brushes made up of three different materials, two different geometries, and different bristle lengths and thicknesses were tested under laboratory conditions against AZ93 and AlFEP. Two of these brushes, the Zephyr fiberglass fingerprint brush and the Escoda nylon fan brush, removed over 90 percent of the dust, and so were tested in the fourth effort in the LDAB. They also performed well under these conditions recovering 80 percent or more of the original thermal performance (solar absorptance/thermal emittance) of both AZ93 and AgFEP after 20 strokes, and 90 or more percent after 200 strokes.
Motivation in vigilance - Effects of self-evaluation and experimenter-controlled feedback.
NASA Technical Reports Server (NTRS)
Warm, J. S.; Kanfer, F. H.; Kuwada, S.; Clark, J. L.
1972-01-01
Vigilance experiments have been performed to study the relative efficiency of feedback operations in enhancing vigilance performance. Two feedback operations were compared - i.e., experimenter-controlled feedback in the form of knowledge of results (KR) regarding response times to signal detections, and subject-controlled feedback in the form of self-evaluation (SE) of response times to signal detections. The subjects responded to the aperiodic offset of a visual signal during a 1-hr vigil. Both feedback operations were found to enhance performance efficiency: subjects in the KR and SE conditions had faster response times than controls receiving no evaluative feedback. Moreover, the data of the KR and SE groups did not differ significantly from each other. The results are discussed in terms of the hypothesis that self-evaluation is a critical factor underlying the incentive value of KR in vigilance tasks.
Refractory Metal Heat Pipe Life Test - Test Plan and Standard Operating Procedures
NASA Technical Reports Server (NTRS)
Martin, J. J.; Reid, R. S.
2010-01-01
Refractory metal heat pipes developed during this project shall be subjected to various operating conditions to evaluate life-limiting corrosion factors. To accomplish this objective, various parameters shall be investigated, including the effect of temperature and mass fluence on long-term corrosion rate. The test series will begin with a performance test of one module to evaluate its performance and to establish the temperature and power settings for the remaining modules. The performance test will be followed by round-the-clock testing of 16 heat pipes. All heat pipes shall be nondestructively inspected at 6-month intervals. At longer intervals, specific modules will be destructively evaluated. Both the nondestructive and destructive evaluations shall be coordinated with Los Alamos National Laboratory. During the processing, setup, and testing of the heat pipes, standard operating procedures shall be developed. Initial procedures are listed here and, as hardware is developed, will be updated, incorporating findings and lessons learned.
Data-Based Performance Assessments for the DOE Hydropower Advancement Project
DOE Office of Scientific and Technical Information (OSTI.GOV)
March, Patrick; Wolff, Dr. Paul; Smith, Brennan T
2012-01-01
The U. S. Department of Energy s Hydropower Advancement Project (HAP) was initiated to characterize and trend hydropower asset conditions across the U.S.A. s existing hydropower fleet and to identify and evaluate the upgrading opportunities. Although HAP includes both detailed performance assessments and condition assessments of existing hydropower plants, this paper focuses on the performance assessments. Plant performance assessments provide a set of statistics and indices that characterize the historical extent to which each plant has converted the potential energy at a site into electrical energy for the power system. The performance metrics enable benchmarking and trending of performance acrossmore » many projects in a variety contexts (e.g., river systems, power systems, and water availability). During FY2011 and FY2012, assessments will be performed on ten plants, with an additional fifty plants scheduled for FY2013. This paper focuses on the performance assessments completed to date, details the performance assessment process, and describes results from the performance assessments.« less
Evaluation of the long-term performance of six alternative disposal methods for LLRW
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kossik, R.; Sharp, G.; Chau, T.
1995-12-31
The State of New York has carried out a comparison of six alternative disposal methods for low-level radioactive waste (LLRW). An important part of these evaluations involved quantitatively analyzing the long-term (10,000 yr) performance of the methods with respect to dose to humans, radionuclide concentrations in the environment, and cumulative release from the facility. Four near-surface methods (covered above-grade vault, uncovered above-grade vault, below-grade vault, augered holes) and two mine methods (vertical shaft mine and drift mine) were evaluated. Each method was analyzed for several generic site conditions applicable for the state. The evaluations were carried out using RIP (Repositorymore » Integration Program), an integrated, total system performance assessment computer code which has been applied to radioactive waste disposal facilities both in the U.S. (Yucca Mountain, WIPP) and worldwide. The evaluations indicate that mines in intact low-permeability rock and near-surface facilities with engineered covers generally have a high potential to perform well (within regulatory limits). Uncovered above-grade vaults and mines in highly fractured crystalline rock, however, have a high potential to perform poorly, exceeding regulatory limits.« less
Dupré, Olivier; Niesen, Bjoern; De Wolf, Stefaan; Ballif, Christophe
2018-01-18
Multijunction cells may offer a cost-effective route to boost the efficiency of industrial photovoltaics. For any technology to be deployed in the field, its performance under actual operating conditions is extremely important. In this perspective, we evaluate the impact of spectrum, light intensity, and module temperature variations on the efficiency of tandem devices with crystalline silicon bottom cells with a particular focus on perovskite top cells. We consider devices with different efficiencies and calculate their energy yields using field data from Denver. We find that annual losses due to differences between operating conditions and standard test conditions are similar for single-junction and four-terminal tandem devices. The additional loss for the two-terminal tandem configuration caused by current mismatch reduces its performance ratio by only 1.7% when an optimal top cell bandgap is used. Additionally, the unusual bandgap temperature dependence of perovskites is shown to have a positive, compensating effect on current mismatch.
Hybrid Gear Performance Under Loss-of-Lubrication Conditions
NASA Technical Reports Server (NTRS)
Laberge, Kelsen E.; Berkebile, Stephen P.; Handschuh, Robert F.; Roberts, Gary D.
2017-01-01
Hybrid composite gear technology is being investigated to increase power density in rotorcraft drive systems. These gears differ from conventional steel gears in that the structural web material is replaced with a lightweight carbon fiber composite. Past studies have focused on performance of this technology under normal operating conditions, however, for this technology to be viable it must also withstand adverse conditions. The study presented here evaluates the performance of hybrid gears under loss-of-lubrication conditions in NASA Glenn Research Centers Contact Fatigue Test Facility. Two experiments are presented using small-scale 3.5 inch (8.9 cm) pitch diameter hybrid gears and compared to a baseline steel gear pair. Results of these tests show that there are limitations to the use of a hexagonal interlock pattern between the steel and composite. There is also evidence that the presence of polymer in the gear during an oil out event has a potential to increase time to failure. Further studies are planned to expand on these initial findings.
Performance assessment of a closed-loop system for diabetes management.
Martinez-Millana, A; Fico, G; Fernández-Llatas, C; Traver, V
2015-12-01
Telemedicine systems can play an important role in the management of diabetes, a chronic condition that is increasing worldwide. Evaluations on the consistency of information across these systems and on their performance in a real situation are still missing. This paper presents a remote monitoring system for diabetes management based on physiological sensors, mobile technologies and patient/doctor applications over a service-oriented architecture that has been evaluated in an international trial (83,905 operation records). The proposed system integrates three types of running environments and data engines in a single service-oriented architecture. This feature is used to assess key performance indicators comparing them with other type of architectures. Data sustainability across the applications has been evaluated showing better outcomes for full integrated sensors. At the same time, runtime performance of clients has been assessed spotting no differences regarding the operative environment.
Crew Exploration Vehicle Launch Abort Controller Performance Analysis
NASA Technical Reports Server (NTRS)
Sparks, Dean W., Jr.; Raney, David L.
2007-01-01
This paper covers the simulation and evaluation of a controller design for the Crew Module (CM) Launch Abort System (LAS), to measure its ability to meet the abort performance requirements. The controller used in this study is a hybrid design, including features developed by the Government and the Contractor. Testing is done using two separate 6-degree-of-freedom (DOF) computer simulation implementations of the LAS/CM throughout the ascent trajectory: 1) executing a series of abort simulations along a nominal trajectory for the nominal LAS/CM system; and 2) using a series of Monte Carlo runs with perturbed initial flight conditions and perturbed system parameters. The performance of the controller is evaluated against a set of criteria, which is based upon the current functional requirements of the LAS. Preliminary analysis indicates that the performance of the present controller meets (with the exception of a few cases) the evaluation criteria mentioned above.
NASA Astrophysics Data System (ADS)
Singare, P. U.
2014-07-01
Radioanalytical technique using 131I and 82Br was employed to evaluate organic based anion exchange resins Tulsion A-30 and Indion-930A. The evaluation was based on performance of these resins during iodide and bromide ion-isotopic exchange reactions. It was observed that for iodide ion-isotopic exchange reaction by using Tulsion A-30 resin, the values of specific reaction rate (min-1), amount of iodide ion exchanged (mmol), initial rate of iodide ion exchange (mmol/min) and log K d were 0.238, 0.477, 0.114, and 11.0, respectively, which was higher than 0.155, 0.360, 0.056, and 7.3, respectively as that obtained by using Indion-930A resins under identical experimental conditions of 40.0°C, 1.000 g of ion exchange resins and 0.003 M labeled iodide ion solution. Also at a constant temperature of 40.0°C, as the concentration of labeled iodide ion solution increases 0.001 to 0.004 M, for Tulsion A-30 resins the percentage of iodide ions exchanged increases from 59.0 to 65.1%, and from 46.4 to 48.8% for Indion-930A resins under identical experimental conditions. The identical trend was observed for both the resins during bromide ion-isotopic exchange reactions. The overall results indicate that under identical experimental conditions, Tulsion A-30 show superior performance over Indion-930A resins. The results of present experimental work have demonstrated that the radioanalytical technique used here can be successfully applied for characterization of different ion exchange resins so as to evaluate their performance under various process parameters.
The Effect of Reported Head Injury on Team Performance and Partner Evaluation
2015-02-17
4 Measures……………………………………………………………………………… 5 DDD Task…….…………………………………………………………………. 5 Evaluation survey……………………………………………………………….. 5...6 The effects of injury condition on DDD performance and evaluation......................... 7 Discussion...tables 1. Overall team DDD score and evaluation subscales as a function of injury condition….. 7 2. Correlations among the measured variables
INTEGRATED SPEED ESTIMATION MODEL FOR MULTILANE EXPREESSWAYS
NASA Astrophysics Data System (ADS)
Hong, Sungjoon; Oguchi, Takashi
In this paper, an integrated speed-estimation model is developed based on empirical analyses for the basic sections of intercity multilane expressway un der the uncongested condition. This model enables a speed estimation for each lane at any site under arb itrary highway-alignment, traffic (traffic flow and truck percentage), and rainfall conditions. By combin ing this model and a lane-use model which estimates traffic distribution on the lanes by each vehicle type, it is also possible to es timate an average speed across all the lanes of one direction from a traffic demand by vehicle type under specific highway-alignment and rainfall conditions. This model is exp ected to be a tool for the evaluation of traffic performance for expressways when the performance me asure is travel speed, which is necessary for Performance-Oriented Highway Planning and Design. Regarding the highway-alignment condition, two new estimators, called effective horizo ntal curvature and effective vertical grade, are proposed in this paper which take into account the influence of upstream and downstream alignment conditions. They are applied to the speed-estimation model, and it shows increased accuracy of the estimation.
Hoyt, Anne L; Bushman, Don; Lewis, Nathan; Faber, Robert
2012-01-01
How can a formulator have confidence that a preservative system will perform as expected under adverse conditions? Extreme conditions that can lead to the development of "off odors" in the product can be a serious challenge for companies providing home care products in the global market. Formulation and stability testing occur under controlled parameters that simulate limited environmental conditions and microbial challenges are typically performed with a standard inoculum level. While this is an acceptable and dependable process, it does not necessarily assess how well a preservative system can perform under extreme environmental conditions or against unusually high levels of bacterial challenges. This is especially true when formulations are diluted and stored by the end-user. By modifying microbial challenge testing of a liquid dishwashing product to include unexpected dilution schemes, increased microbial assaults, and elevated temperatures, a pattern of preservative efficacy was established. The resulting approach proved to be a useful tool when developing use directions, recommended dilution levels, the overall surfactant system, preservative type, and storage restrictions.
Takano, Kouji; Komatsu, Tomoaki; Hata, Naoki; Nakajima, Yasoichi; Kansaku, Kenji
2009-08-01
The white/gray flicker matrix has been used as a visual stimulus for the so-called P300 brain-computer interface (BCI), but the white/gray flash stimuli might induce discomfort. In this study, we investigated the effectiveness of green/blue flicker matrices as visual stimuli. Ten able-bodied, non-trained subjects performed Alphabet Spelling (Japanese Alphabet: Hiragana) using an 8 x 10 matrix with three types of intensification/rest flicker combinations (L, luminance; C, chromatic; LC, luminance and chromatic); both online and offline performances were evaluated. The accuracy rate under the online LC condition was 80.6%. Offline analysis showed that the LC condition was associated with significantly higher accuracy than was the L or C condition (Tukey-Kramer, p < 0.05). No significant difference was observed between L and C conditions. The LC condition, which used the green/blue flicker matrix was associated with better performances in the P300 BCI. The green/blue chromatic flicker matrix can be an efficient tool for practical BCI application.
On the estimation algorithm used in adaptive performance optimization of turbofan engines
NASA Technical Reports Server (NTRS)
Espana, Martin D.; Gilyard, Glenn B.
1993-01-01
The performance seeking control algorithm is designed to continuously optimize the performance of propulsion systems. The performance seeking control algorithm uses a nominal model of the propulsion system and estimates, in flight, the engine deviation parameters characterizing the engine deviations with respect to nominal conditions. In practice, because of measurement biases and/or model uncertainties, the estimated engine deviation parameters may not reflect the engine's actual off-nominal condition. This factor has a necessary impact on the overall performance seeking control scheme exacerbated by the open-loop character of the algorithm. The effects produced by unknown measurement biases over the estimation algorithm are evaluated. This evaluation allows for identification of the most critical measurements for application of the performance seeking control algorithm to an F100 engine. An equivalence relation between the biases and engine deviation parameters stems from an observability study; therefore, it is undecided whether the estimated engine deviation parameters represent the actual engine deviation or whether they simply reflect the measurement biases. A new algorithm, based on the engine's (steady-state) optimization model, is proposed and tested with flight data. When compared with previous Kalman filter schemes, based on local engine dynamic models, the new algorithm is easier to design and tune and it reduces the computational burden of the onboard computer.
Camargo, Marcela R; Barela, José A; Nozabieli, Andréa J L; Mantovani, Alessandra M; Martinelli, Alessandra R; Fregonesi, Cristina E P T
2015-01-01
The aims of this study were to evaluate aspects of balance, ankle muscle strength and spatiotemporal gait parameters in individuals with diabetic peripheral neuropathy (DPN) and verify whether deficits in spatiotemporal gait parameters were associated with ankle muscle strength and balance performance. Thirty individuals with DPN and 30 control individuals have participated. Spatiotemporal gait parameters were evaluated by measuring the time to walk a set distance during self-selected and maximal walking speeds. Functional mobility and balance performance were assessed using the Functional Reach and the Time Up and Go tests. Ankle isometric muscle strength was assessed with a handheld digital dynamometer. Analyses of variance were employed to verify possible differences between groups and conditions. Multiple linear regression analysis was employed to uncover possible predictors of gait deficits. Gait spatiotemporal, functional mobility, balance performance and ankle muscle strength were affected in individuals with DPN. The Time Up and Go test performance and ankle muscle isometric strength were associated to spatiotemporal gait changes, especially during maximal walking speed condition. Functional mobility and balance performance are damaged in DPN and balance performance and ankle muscle strength can be used to predict spatiotemporal gait parameters in individuals with DPN. Copyright © 2015 Diabetes India. Published by Elsevier Ltd. All rights reserved.
Masticatory performance alters stress relief effect of gum chewing.
Nishigawa, Keisuke; Suzuki, Yoshitaka; Matsuka, Yoshizo
2015-10-01
We evaluated the effects of gum chewing on the response to psychological stress induced by a calculation task and investigated the relationship between this response and masticatory performance. Nineteen healthy adult volunteers without dental problems undertook the Uchida-Kraepelin (UK) test (30 min of reiterating additions of one-digit numbers). Before and immediately after the test, saliva samples were collected from the sublingual area of the participants. Three min after the UK test, the participants were made to chew flavorless gum for 3 min, and the final saliva samples were collected 10 min after the UK test. The experiment was performed without gum chewing on a different day. Masticatory performance was evaluated using color-changing chewing gum. Salivary CgA levels at immediately and 10 min after the UK test were compared with and without gum chewing condition. Two-way repeated measures analysis of variance revealed significant interaction between gum chewing condition and changes in CgA levels during post 10 min UK test period. A significant correlation was found between changes in CgA levels and masticatory performance in all participants. Our results indicate that gum chewing may relieve stress responses; however, high masticatory performance is required to achieve this effect. Copyright © 2015 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
Development of mainshaft seals for advanced air breathing propulsion systems
NASA Technical Reports Server (NTRS)
Dobek, L. J.
1973-01-01
A gas-film face seal design incorporating shrouded Rayleigh step lift pads at the primary sealing face was analyzed for performance over a wide range of gas turbine engine conditions. Acceptable leakage rates and operation without rubbing contact was predicted for engine conditions that included sealed pressures to 500 psi, sliding speeds to 600 ft/sec, and sealed gas temperatures to 1200 F. In the experimental evaluation, measured gas leakage rates were, in general, close to that predicted and sometimes lower. Satisfactory performance of the gas-film seal was demonstrated at the maximum seal seat axial runout expected in present positive contact face seal applications. Stable operation was shown when testing was performed with air-entrained dirt.
Stability of user-friendly blood typing kits stored under typical military field conditions.
Bienek, Diane R; Chang, Cheow K; Charlton, David G
2009-10-01
To help preserve in-theater strength within deployed military units, commercially available, rapid, user-friendly ABO-Rh blood typing kits were evaluated to determine their stability in storage conditions commonly encountered by the warfighter. Methods for environmental exposure testing were based on MIL-STD-810F. When Eldon Home Kits 2511 were exposed to various temperature/relative humidity conditions, the results were comparable to those obtained with the control group and those obtained with industry-standard methods. For the ABO-Rh Combination Blood Typing Experiment Kits, 2 of the exposure treatments rendered them unusable. In addition, a third set of exposure treatments adversely affected the kits, resulting in approximately 30% blood type misclassifications. Collectively, this evaluation of commercial blood typing kits revealed that diagnostic performance can vary between products, lots, and environmental storage conditions.
Spanwise morphing trailing edge on a finite wing
NASA Astrophysics Data System (ADS)
Pankonien, Alexander M.; Inman, Daniel J.
2015-04-01
Unmanned Aerial Vehicles are prime targets for morphing implementation as they must adapt to large changes in flight conditions associated with locally varying wind or large changes in mass associated with payload delivery. The Spanwise Morphing Trailing Edge concept locally varies the trailing edge camber of a wing or control surface, functioning as a modular replacement for conventional ailerons without altering the spar box. Utilizing alternating active sections of Macro Fiber Composites (MFCs) driving internal compliant mechanisms and inactive sections of elastomeric honeycombs, the SMTE concept eliminates geometric discontinuities associated with shape change, increasing aerodynamic performance. Previous work investigated a representative section of the SMTE concept and investigated the effect of various skin designs on actuation authority. The current work experimentally evaluates the aerodynamic gains for the SMTE concept for a representative finite wing as compared with a conventional, articulated wing. The comparative performance for both wings is evaluated by measuring the drag penalty associated with achieving a design lift coefficient from an off-design angle of attack. To reduce experimental complexity, optimal control configurations are predicted with lifting line theory and experimentally measured control derivatives. Evaluated over a range of off-design flight conditions, this metric captures the comparative capability of both concepts to adapt or "morph" to changes in flight conditions. Even with this simplistic model, the SMTE concept is shown to reduce the drag penalty due to adaptation up to 20% at off-design conditions, justifying the increase in mass and complexity and motivating concepts capable of larger displacement ranges, higher fidelity modelling, and condition-sensing control.
Evaluation of Honeywell Recoverable Computer System (RCS) in Presence of Electromagnetic Effects
NASA Technical Reports Server (NTRS)
Malekpour, Mahyar
1997-01-01
The design and development of a Closed-Loop System to study and evaluate the performance of the Honeywell Recoverable Computer System (RCS) in electromagnetic environments (EME) is presented. The development of a Windows-based software package to handle the time critical communication of data and commands between the RCS and flight simulation code in real-time, while meeting the stringent hard deadlines is also presented. The performance results of the RCS while exercising flight control laws under ideal conditions as well as in the presence of electromagnetic fields is also discussed.
Vehicle test report: Battronic pickup truck
NASA Technical Reports Server (NTRS)
Price, T. W.; Shain, T. W.; Freeman, R. J.; Pompa, M. F.
1982-01-01
An electric pickup truck was tested to characterize certain parameters and to provide baseline data that can be used for the comparison of improved batteries that may be incorporated into the vehicle at a later time. The vehicle tests were concentrated on the electrical drive subsystem; i.e., the batteries, controller, and motor. The tests included coastdowns to characterize the road load and range evaluations for both cyclic and constant speed conditions. A qualitative evaluation of the vehicle's performance was made by comparing its constant speed range performance with other vehicles.
NASA Astrophysics Data System (ADS)
Tang, Liang; Cong, Shengyi; Ling, Xianzhang; Ju, Nengpan
2017-01-01
Boundary conditions can significantly affect a slope's behavior under strong earthquakes. To evaluate the importance of boundary conditions for finite element (FE) simulations of a shake-table experiment on the slope response, a validated three-dimensional (3D) nonlinear FE model is presented, and the numerical and experimental results are compared. For that purpose, the robust graphical user-interface "SlopeSAR", based on the open-source computational platform OpenSees, is employed, which simplifies the effort-intensive pre- and post-processing phases. The mesh resolution effect is also addressed. A parametric study is performed to evaluate the influence of boundary conditions on the FE model involving the boundary extent and three types of boundary conditions at the end faces. Generally, variations in the boundary extent produce inconsistent slope deformations. For the two end faces, fixing the y-direction displacement is not appropriate to simulate the shake-table experiment, in which the end walls are rigid and rough. In addition, the influence of the length of the 3D slope's top face and the width of the slope play an important role in the difference between two types of boundary conditions at the end faces (fixing the y-direction displacement and fixing the ( y, z) direction displacement). Overall, this study highlights that the assessment of a comparison between a simulation and an experimental result should be performed with due consideration to the effect of the boundary conditions.
Evaluating Hydrogen Evolution and Oxidation in Alkaline Media to Establish Baselines
Alia, Shaun M.; Pivovar, Bryan S.
2018-04-28
This paper fills a significant gap in the literature for alkaline hydrogen evolution (HER) and oxidation (HOR) baseline performance, while reviewing the different variables that influence observed properties. Although high-performing HER-HOR catalysts in acidic electrolytes are too active to measure kinetic in rotating disk electrode (RDE) half-cells, under alkaline conditions RDE kinetics evaluations are relevant and half-cell performances are comparable to hydrogen pump data. This paper focuses on best practices to ensure that half-cell tests don't unnecessarily lower platinum group metal (PGM) performance or improve non-PGM performance. Specific aspects examined include experiments on PGMs minimizing the impact of impurities (electrolyte,more » cell material) and experiments on non-PGMs minimizing the impact from test protocols (counter electrode).« less
Evaluating Hydrogen Evolution and Oxidation in Alkaline Media to Establish Baselines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alia, Shaun M.; Pivovar, Bryan S.
This paper fills a significant gap in the literature for alkaline hydrogen evolution (HER) and oxidation (HOR) baseline performance, while reviewing the different variables that influence observed properties. Although high-performing HER-HOR catalysts in acidic electrolytes are too active to measure kinetic in rotating disk electrode (RDE) half-cells, under alkaline conditions RDE kinetics evaluations are relevant and half-cell performances are comparable to hydrogen pump data. This paper focuses on best practices to ensure that half-cell tests don't unnecessarily lower platinum group metal (PGM) performance or improve non-PGM performance. Specific aspects examined include experiments on PGMs minimizing the impact of impurities (electrolyte,more » cell material) and experiments on non-PGMs minimizing the impact from test protocols (counter electrode).« less
Santos, Rafael D.; Boote, Kenneth J.; Sollenberger, Lynn E.; Neves, Andre L. A.; Pereira, Luiz G. R.; Scherer, Carolina B.; Gonçalves, Lucio C.
2017-01-01
Forage production is primarily limited by weather conditions under dryland production systems in Brazilian semi-arid regions, therefore sowing at the appropriate time is critical. The objectives of this study were to evaluate the CSM-CERES-Pearl Millet model from the DSSAT software suite for its ability to simulate growth, development, and forage accumulation of pearl millet [Pennisetum glaucum (L.) R.] at three Brazilian semi-arid locations, and to use the model to study the impact of different sowing dates on pearl millet performance for forage. Four pearl millet cultivars were grown during the 2011 rainy season in field experiments conducted at three Brazilian semi-arid locations, under rainfed conditions. The genetic coefficients of the four pearl millet cultivars were calibrated for the model, and the model performance was evaluated with experimental data. The model was run for 14 sowing dates using long-term historical weather data from three locations, to determine the optimum sowing window. Results showed that performance of the model was satisfactory as indicated by accurate simulation of crop phenology and forage accumulation against measured data. The optimum sowing window varied among locations depending on rainfall patterns, although showing the same trend for cultivars within the site. The best sowing windows were from 15 April to 15 May for the Bom Conselho location; 12 April to 02 May for Nossa Senhora da Gloria; and 17 April to 25 May for Sao Bento do Una. The model can be used as a tool to evaluate the effect of sowing date on forage pearl millet performance in Brazilian semi-arid conditions. PMID:29276521
ERIC Educational Resources Information Center
Worobey, John; Worobey, Harriet S.
1999-01-01
Two studies examined nutritional differences between home breakfasts and breakfasts served at preschool following School Breakfast Program guidelines and evaluated nutritional impact of program participation on 4-year olds' preacademic performance. Results indicated that breakfast intake was altered under school breakfast conditions. Performance…
ERIC Educational Resources Information Center
Park, Sungho; Singer, George H. S.; Gibson, Mary
2005-01-01
The study uses an alternating treatment design to evaluate the functional effect of teacher's affect on students' task performance. Tradition in special education holds that teachers should engage students using positive and enthusiastic affect for task presentations and praise. To test this assumption, we compared two affective conditions. Three…
General Electric 20-ampere hour nickel-cadmium battery
NASA Technical Reports Server (NTRS)
Kirsch, W. W.
1974-01-01
The interaction, effect, and controllability of the performance parameters of the General Electric 20-ampere-hour, 24-cell nickel cadmium battery are investigated. The battery was cycled under simulated orbit conditions. The acquired data was analyzed and evaluated in terms of battery parameters and performance characteristics. Conclusions and tests results are presented along with recommendations for further study.
ERIC Educational Resources Information Center
FLINT, LANNING L.; HATCH, RICHARD S.
STUDENT PERFORMANCE VARIABLES UNDER AUTOMATED, CONVENTIONAL, AND A COMBINATION OF AUTOMATED AND CONVENTIONAL CONDITIONS OF INSTRUCTION WERE INVESTIGATED. RECOMMENDATIONS FOR THE INTEGRATION OF PROGRAMED MATERIAL INTO THE CLASSROOM WERE SOUGHT. THREE GROUPS OF JUNIOR COLLEGE STUDENTS WERE USED IN THE EXPERIMENT. THE GROUPS WERE CHOSEN AT RANDOM.…
An Example of an Elementary School Paraprofessional-Implemented Functional Analysis and Intervention
ERIC Educational Resources Information Center
Bessette, Kimberly K.; Wills, Howard P.
2007-01-01
The Individuals With Disabilities Education Act mandates the performance of functional assessment for students with severe behavior problems. A functional analysis can be one part of this process but its use has been minimal. This study evaluates whether a paraprofessional could (a) be trained to correctly perform 3 conditions of a functional…
NASA Technical Reports Server (NTRS)
Nurick, W. H.
1974-01-01
An evaluation of reusable thrust chambers for the space shuttle orbit maneuvering engine was conducted. Tests were conducted using subscale injector hot-fire procedures for the injector configurations designed for a regenerative cooled engine. The effect of operating conditions and fuel temperature on combustion chamber performance was determined. Specific objectives of the evaluation were to examine the optimum like-doublet element geometry for operation at conditions consistent with a fuel regeneratively cooled engine (hot fuel, 200 to 250 F) and the sensitivity of the triplet injector element to hot fuels.
Experimental pavement delineation treatments
NASA Astrophysics Data System (ADS)
Bryden, J. E.; Lorini, R. A.
1981-06-01
Visibility and durability of materials used to delineate shoulders and medians adjacent to asphalt pavements were evaluated. Materials evaluated were polysulfide and coal tar epoxies, one and two component polyesters, portland cement, acrylic paints, modified-alkyd traffic paint, preformed plastic tape, and thermoplastic markings. Neat applications, sand mortars, and surface treatments were installed in several geometric patterns including cross hatches, solid median treatments, and various widths of edge lines. Thermoplastic pavement markings generally performed very well, providing good visibility under adverse viewing conditions for at least 4 years. Thermoplastic 4 in. wide edge lines appear to provide adequate visibility for most conditions.
Clinical assessment of nutritional status and feeding programs in horses.
Becvarova, Iveta; Pleasant, R Scott; Thatcher, Craig D
2009-04-01
Veterinarians are a primary source of nutritional information and advice for horse owners. This article reviews methods for clinical assessment of nutritional status and feeding programs that can be applied to an individual horse or group of horses. Physical examination, including measurement of body weight and evaluation of body condition score, estimation of nutrient requirements and the nutrient content of the horse's diet, and evaluation of the feeding method are important components of the assessment. Ongoing clinical assessment of health and body condition will gauge the need for reassessment of the feeding plan. Obvious indications for prompt reevaluation of diet and feeding include changes in health status (eg, body condition), life stage or physiologic state (eg, pregnancy), or performance status.
An experimental evaluation of the performance deficit of an aircraft engine starter turbine
NASA Technical Reports Server (NTRS)
Haas, J. E.; Roelke, R. J.; Hermann, P.
1980-01-01
An experimental investigation is presented to determine the aerodynamic performance deficit of a 13.5 - centimeter-tip-diameter aircraft engine starter turbine. The two-phased evaluation comprised both the stator and the stage performance, and the experimental design is described in detail. Data obtained from the investigation of three honeycomb shrouds clearly showed that the filled honeycomb reached a total efficiency of 0.868, 8.2 points higher than the open honeycomb shroud, at design equivalent conditions of speed and blade-jet speed ratio. It was concluded that the use of an open honeycomb shroud caused the large performance deficit for the starter turbine. Further research is suggested to ascertain stator inlet boundary layer measurements.
Metrology Standards for Quantitative Imaging Biomarkers
Obuchowski, Nancy A.; Kessler, Larry G.; Raunig, David L.; Gatsonis, Constantine; Huang, Erich P.; Kondratovich, Marina; McShane, Lisa M.; Reeves, Anthony P.; Barboriak, Daniel P.; Guimaraes, Alexander R.; Wahl, Richard L.
2015-01-01
Although investigators in the imaging community have been active in developing and evaluating quantitative imaging biomarkers (QIBs), the development and implementation of QIBs have been hampered by the inconsistent or incorrect use of terminology or methods for technical performance and statistical concepts. Technical performance is an assessment of how a test performs in reference objects or subjects under controlled conditions. In this article, some of the relevant statistical concepts are reviewed, methods that can be used for evaluating and comparing QIBs are described, and some of the technical performance issues related to imaging biomarkers are discussed. More consistent and correct use of terminology and study design principles will improve clinical research, advance regulatory science, and foster better care for patients who undergo imaging studies. © RSNA, 2015 PMID:26267831