Zonies, David; Mack, Christopher; Kramer, Bradley; Rivara, Frederick; Klein, Matthew
2009-01-01
Background Although comprehensive burn care requires significant resources, patients may be treated at verified burn centers, non-verified burn centers, or other facilities due to a variety of factors. The purpose of this study was to evaluate the association between patient and injury characteristics and treatment location using a national database. Study Design We performed an analysis of all burn patients admitted to United States hospitals participating in the Healthcare Cost and Utilization Project over 2 years. Univariate and multivariate analyses were performed to identify patient and injury factors associated with the likelihood of treatment at designated burn care facilities. Definitve care facilities were categorized as American Burn Association verified centers, non-verified burn centers, or other facilities. Results Over the two years, 29,971 burn patients were treated in 1,376 hospitals located in 19 participating states. A total of 6,712 (22%) patients were treated at verified centers, with 26% and 52% treated at non-verified or other facilities, respectively. Patients treated at verified centers were younger than those at non-verified or other facilities (33.1 years vs. 33.7 years vs. 41.9 years, p<0.001) and had a higher rate of inhalation injury (3.4% vs. 3.2% vs. 2.2%, p<0.001). Independent factors associated with treatment at verified centers include burns to the head/neck (RR 2.4, CI 2.1-2.7), hand (RR 1.8, CI 1.6-1.9), electrical injury (RR 1.4, CI 1.4, CI 1.2-1.7), and fewer co-morbidities (RR 0.55, CI 0.5-0.6). Conclusions More than two-thirds of significantly burned patients are treated at non-verified burn centers in the U.S. Many patients meeting ABA criteria for transfer to a burn center are being treated at non-burn center facilities. PMID:20193892
Student Perceptions of Classroom Achievement Goal Structure: Is It Appropriate to Aggregate?
ERIC Educational Resources Information Center
Lam, Arena C.; Ruzek, Erik A.; Schenke, Katerina; Conley, AnneMarie M.; Karabenick, Stuart A.
2015-01-01
Student reports are a common approach to characterizing how students experience their classrooms. We used a recently developed method--multilevel confirmatory factor analysis--to determine whether commonly employed measures of achievement goal structure constructs (mastery and performance) typically verified at the student level can be verified at…
Domingues, Rosa Maria Soares Madeira; Leal, Maria do Carmo
2016-06-20
The objectives were to estimate incidence of congenital syphilis and verify factors associated with vertical transmission. A national hospital-based study was performed in 2011-2012 with 23,894 postpartum women using an in-hospital interview and data from patient charts and prenatal cards. Univariate logistic regression was performed to verify factors associated with congenital syphilis. Estimated incidence of congenital syphilis was 3.51 per 1,000 live births (95%CI: 2.29-5.37) and vertical transmission rate was 34.3% (95%CI: 24.7-45.4). Congenital syphilis was associated with lower maternal schooling, black skin color, higher rate of risk factors for prematurity, late initiation of prenatal care, fewer prenatal visits, and lower rate of prenatal serological testing. Fetal mortality was six times higher in congenital syphilis, and newborns with congenital syphilis showed higher hospital admission rates. Congenital syphilis is a persistent public health problem in Brazil and is associated with greater social vulnerability and gaps in prenatal care.
A Theoretical Structure of High School Concert Band Performance
ERIC Educational Resources Information Center
Bergee, Martin J.
2015-01-01
This study used exploratory (EFA) and confirmatory factor analysis (CFA) to verify a theoretical structure for high school concert band performance and to test that structure for viability, generality, and invariance. A total of 101 university students enrolled in two different bands rated two high school band performances (a "first"…
Verbal Neuropsychological Functions in Aphasia: An Integrative Model
ERIC Educational Resources Information Center
Vigliecca, Nora Silvana; Báez, Sandra
2015-01-01
A theoretical framework which considers the verbal functions of the brain under a multivariate and comprehensive cognitive model was statistically analyzed. A confirmatory factor analysis was performed to verify whether some recognized aphasia constructs can be hierarchically integrated as latent factors from a homogenously verbal test. The Brief…
NASA Astrophysics Data System (ADS)
Gajic, Gordana; Stankovski, Stevan; Ostojic, Gordana; Tesic, Zdravko; Miladinovic, Ljubomir
2014-01-01
The so far implemented enterprise resource planning (ERP) systems have in many cases failed to meet the requirements regarding the business process control, decrease of business costs and increase of company profit margin. Therefore, there is a real need for an evaluation of the influence of ERP on the company's performance indicators. Proposed in this article is an advanced model for the evaluation of the success of ERP implementation on organisational and operational performance indicators in oil-gas companies. The recommended method establishes a correlation between a process-based method, a scorecard model and ERP critical success factors. The method was verified and tested on two case studies in oil-gas companies using the following procedure: the model was developed, tested and implemented in a pilot gas-oil company, while the results were implemented and verified in another gas-oil company.
ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: PAINT OVERSPRAY ARRESTOR, FARR COMPANY RIGA-FLO 200
Paint overspray arrestors (POAs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the particle filtration efficiency as a function of size for particles smaller than...
ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: PAINT OVERSPRAY ARRESTOR, ATI OSM 200 SYSTEM
Paint overspray arrestors (POAs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the particle filtration efficiency as a function of size for particles smaller than...
ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: PAINT OVERSPRAY ARRESTOR, COLUMBUS INDUSTRIES SL-46B
Paint overspray arrestors (POAs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the particle filtration efficiency as a function of size for particles smaller than...
Paint overspray arrestors (POAs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the particle filtration efficiency as a function of size for particles smaller than...
Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of th...
Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of th...
Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of th...
Paint overspray arrestors (POAs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the particle filtration efficiency as a function of size for particles smaller than...
Paint overspray arrestors (POAs) were evaluated by the Air Pollution Control Technology (APCT) Verification Center. The performance factor verified was the particle filtration efficiency as a function of size for particles smaller than 10 micrometers. The APCT Verification Center...
Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of th...
Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of th...
Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of th...
DOT National Transportation Integrated Search
2014-09-01
The primary objectives of this research are to monitor the : short-term and long-term behavior and performance of inservice : GRS-IBS abutments in the state of Louisiana, and to : verify important design factors and parameters for GRS-IBS : abutment,...
Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) Verification Center. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of the size of those particles equal to and smalle...
Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) Verification Center. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of the size of those particles equal to and smalle...
Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of th...
Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) Verification Center. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of the size of those particles equal to and smalle...
Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of th...
Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) Verification Center. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of the size for particles equal to or smaller than...
Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) Verification Center. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of the size of those particles equal to and smalle...
Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of th...
Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) Verification Center. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of the size for particles equal to or smaller than...
Paint overspray arrestors (POAs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the particle filtration efficiency as a function of size for particles smaller than...
Performance testing of a 50 kW VAWT in a built-up environment
NASA Technical Reports Server (NTRS)
Schienbein, L. A.
1981-01-01
The results of performance tests of a DAF Indal 50 kW vertical axis wind turbine are presented. Results of limited free stream turbulence and vertical wind shear measurements at the site are also presented. The close agreement between measured and predicted energy outputs, required to verify the wind turbine power output performance relationship, was not attained. A discussion is presented of factors that may have contributed to the lack of better agreement.
Development and validity of a scale to measure workplace culture of health.
Kwon, Youngbum; Marzec, Mary L; Edington, Dee W
2015-05-01
To describe the development of and test the validity and reliability of the Workplace Culture of Health (COH) scale. Exploratory factor analysis and confirmatory factor analysis were performed on data from a health care organization (N = 627). To verify the factor structure, confirmatory factor analysis was performed on a second data set from a medical equipment manufacturer (N = 226). The COH scale included a structure of five orthogonal factors: senior leadership and polices, programs and rewards, quality assurance, supervisor support, and coworker support. With regard to construct validity (convergent and discriminant) and reliability, two different US companies showed the same factorial structure, satisfactory fit statistics, and suitable internal and external consistency. The COH scale represents a reliable and valid scale to assess the workplace environment and culture for supporting health.
Growth factors, muscle function, and doping.
Goldspink, Geoffrey; Wessner, Barbara; Tschan, Harald; Bachl, Norbert
2010-03-01
This article discusses the inevitable use of growth factors for enhancing muscle strength and athletic performance. Much effort has been expended on developing a treatment of muscle wasting associated with a range of diseases and aging. Frailty in the aging population is a major socioeconomic and medical problem. Emerging molecular techniques have made it possible to gain a better understanding of the growth factor genes and how they are activated by physical activity. The ways that misuse of growth factors may be detected and verified in athletes and future challenges for detecting manipulation of signaling pathways are discussed. Copyright 2010. Published by Elsevier Inc.
SU-E-T-100: Designing a QA Tool for Enhance Dynamic Wedges Based On Dynalog Files
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yousuf, A; Hussain, A
2014-06-01
Purpose: A robust quality assurance (QA) program for computer controlled enhanced dynamic wedge (EDW) has been designed and tested. Calculations to perform such QA test is based upon the EDW dynamic log files generated during dose delivery. Methods: Varian record and verify system generates dynamic log (dynalog) files during dynamic dose delivery. The system generated dynalog files contain information such as date and time of treatment, energy, monitor units, wedge orientation, and type of treatment. It also contains the expected calculated segmented treatment tables (STT) and the actual delivered STT for the treatment delivery as a verification record. These filesmore » can be used to assess the integrity and precision of the treatment plan delivery. The plans were delivered with a 6 MV beam from a Varian linear accelerator. For available EDW angles (10°, 15°, 20°, 25°, 30°, 45°, and 60°) Varian STT values were used to manually calculate monitor units for each segment. It can also be used to calculate the EDW factors. Independent verification of fractional MUs per segment was performed against those generated from dynalog files. The EDW factors used to calculate MUs in TPS were dosimetrically verified in solid water phantom with semiflex chamber on central axis. Results: EDW factors were generated from the STT provided by Varian and verified against practical measurements. The measurements were in agreement of the order of 1 % to the calculated EDW data. Variation between the MUs per segment obtained from dynalog files and those manually calculated was found to be less than 2%. Conclusion: An efficient and easy tool to perform routine QA procedure of EDW is suggested. The method can be easily implemented in any institution without a need for expensive QA equipment. An error of the order of ≥2% can be easily detected.« less
Shin, Hee Kon; Kang, Seok Hoon; Lim, Sun-Hye; Yang, Jeong Hee; Chae, Sunguk
2016-01-01
Medical students are usually under more stress than that experienced by non-medical students. Stress testing tools for Korean medical students have not been sufficiently studied. Thus, we adapted and modified the East Asian Student Stress Inventory (EASSI), a stress testing tool for Korean students studying abroad, and verified its usefulness as a stress test in Korean university students. We also compared and analyzed stress levels between medical and non-medical students. A questionnaire survey was conducted on medical and non-medical students of a national university, and the responses of 224 students were analyzed for this study. Factor analysis and reliability testing were performed based on data collected for 25 adapted EASSI questions and those on the Korean version of the Global Assessment of Recent Stress Scale (GARSS). A correlation analysis was performed between the 13 modified EASSI questions and the GARSS, and validity of the modified EASSI was verified by directly comparing stress levels between the two student groups. The 13 questions adapted for the EASSI were called the modified EASSI and classified into four factors through a factor analysis and reliability testing. The Pearson's correlation analysis revealed a significant correlation between the modified EASSI and the Korean version of the GARSS, suggesting a complementary strategy of using both tests. The validity and reliability of the EASSI were verified. The modified Korean EASSI could be a useful stress test for Korean medical students. Our results show that medical students were under more stress than that of non-medical students. Thus, these results could be helpful for managing stress in medical students.
Caci, Barbara; Cardaci, Maurizio; Scrima, Fabrizio; Tabacchi, Marco Elio
2017-04-01
The studies reported analyze the factorial structure of Facebook Addiction Italian Questionnaire (FAIQ), a variant of 20-item Young's Internet Addiction Test (IAT). In Study 1, we tested FAIQ psychometric properties using exploratory factor analysis (EFA). In Study 2, we performed a confirmatory factor analysis (CFA) to verify the FAIQ factorial structure identified through EFA. Results from CFA confirm the presence of a four-factor model accounting for 58 percent of total variance, plus a general higher order factor that best fits the data. Further relationships between FAIQ factor scores, personality, and Facebook usage have been explored.
Performance analysis of hybrid vibrational energy harvesters with experimental verification
NASA Astrophysics Data System (ADS)
Sriramdas, Rammohan; Pratap, Rudra
2018-07-01
In the present work, performance indices for a hybrid energy harvester (HEH) that is composed of piezoelectric and electrodynamic or electromagnetic mechanisms of energy conversion are analyzed. Performance of a HEH is defined in terms of Q-normalized power factor and efficiency of conversion. They are observed to acutely depend on coupling strength or figures of merit in both piezoelectric and electrodynamic domains. The influence of figures of merit on the Q-normalized power factor, and the limits of conversion efficiency are explored. Based on the studies, a suitable range for figures of merit that would maximize both Q-normalized power factor and conversion efficiency in hybrid harvesters is proposed. The proposed idea is verified experimentally for the appropriate values of figures of merit and efficiencies by fabricating and testing four experimental models of the HEHs.
RZA-NLMF algorithm-based adaptive sparse sensing for realizing compressive sensing
NASA Astrophysics Data System (ADS)
Gui, Guan; Xu, Li; Adachi, Fumiyuki
2014-12-01
Nonlinear sparse sensing (NSS) techniques have been adopted for realizing compressive sensing in many applications such as radar imaging. Unlike the NSS, in this paper, we propose an adaptive sparse sensing (ASS) approach using the reweighted zero-attracting normalized least mean fourth (RZA-NLMF) algorithm which depends on several given parameters, i.e., reweighted factor, regularization parameter, and initial step size. First, based on the independent assumption, Cramer-Rao lower bound (CRLB) is derived as for the performance comparisons. In addition, reweighted factor selection method is proposed for achieving robust estimation performance. Finally, to verify the algorithm, Monte Carlo-based computer simulations are given to show that the ASS achieves much better mean square error (MSE) performance than the NSS.
Design and numerical simulation of novel giant magnetostrictive ultrasonic transducer
NASA Astrophysics Data System (ADS)
Li, Pengyang; Liu, Qiang; Li, Shujuan; Wang, Quandai; Zhang, Dongya; Li, Yan
This paper provides a design method of a novel giant magnetostrictive ultrasonic transducer utilized in incremental sheet metal forming. The frequency equations of the ultrasonic vibrator were deduced and the corresponding correctness verified by the modal and harmonic response characteristic through the finite element method (FEM) and ANSYS software. In addition, the magnetic field of the vibrator system was designed and verified by the ANSYS. Finally, the frequency tests based on the impedance response analysis and the amplitude measurements based on the laser displacement sensor were performed on the prototype. The results confirmed the appropriate design of this transducer, setting the foundation for a low mechanical quality factor and satisfying amplitude.
NASA Astrophysics Data System (ADS)
Yang, Da-Wei; Zhao, Xiu-Ying; Zhang, Geng; Li, Qiang-Guo; Wu, Si-Zhu
2016-05-01
Molecule dynamics (MD) simulation, a molecular-level method, was applied to predict the damping properties of AO-60/polyacrylate rubber (AO-60/ACM) composites before experimental measures were performed. MD simulation results revealed that two types of hydrogen bond, namely, type A (AO-60) -OH•••O=C- (ACM), type B (AO-60) - OH•••O=C- (AO-60) were formed. Then, the AO-60/ACM composites were fabricated and tested to verify the accuracy of the MD simulation through dynamic mechanical thermal analysis (DMTA). DMTA results showed that the introduction of AO-60 could remarkably improve the damping properties of the composites, including the increase of glass transition temperature (Tg) alongside with the loss factor (tan δ), also indicating the AO-60/ACM(98/100) had the best damping performance amongst the composites which verified by the experimental.
Passive isolation/damping system for the Hubble space telescope reaction wheels
NASA Technical Reports Server (NTRS)
Hasha, Martin D.
1987-01-01
NASA's Hubble Space Telescope contain large, diffraction limited optics with extraordinary resolution and performance for surpassing existing observatories. The need to reduce structural borne vibration and resultant optical jitter from critical Pointing Control System components, Reaction Wheels, prompted the feasibility investigation and eventual development of a passive isolation system. Alternative design concepts considered were required to meet a host of stringent specifications and pass rigid tests to be successfully verified and integrated into the already built flight vehicle. The final design employs multiple arrays of fluid damped springs that attenuate over a wide spectrum, while confining newly introduced resonances to benign regions of vehicle dynamic response. Overall jitter improvement of roughly a factor of 2 to 3 is attained with this system. The basis, evolution, and performance of the isolation system, specifically discussing design concepts considered, optimization studies, development lessons learned, innovative features, and analytical and ground test verified results are presented.
Dispersive analysis of the pion transition form factor
NASA Astrophysics Data System (ADS)
Hoferichter, M.; Kubis, B.; Leupold, S.; Niecknig, F.; Schneider, S. P.
2014-11-01
We analyze the pion transition form factor using dispersion theory. We calculate the singly-virtual form factor in the time-like region based on data for the cross section, generalizing previous studies on decays and scattering, and verify our result by comparing to data. We perform the analytic continuation to the space-like region, predicting the poorly-constrained space-like transition form factor below , and extract the slope of the form factor at vanishing momentum transfer . We derive the dispersive formalism necessary for the extension of these results to the doubly-virtual case, as required for the pion-pole contribution to hadronic light-by-light scattering in the anomalous magnetic moment of the muon.
Ritter, Aaron R; Leger, Gabriel C; Miller, Justin B; Banks, Sarah J
2017-01-01
Differences in cognition between frontotemporal dementia (FTD) and Alzheimer disease (AD) are well described in clinical cohorts, but have rarely been confirmed in studies with pathologic verification. For emerging therapeutics to succeed, determining underlying pathology early in the disease course is increasingly important. Neuropsychological evaluation is an important component of the diagnostic workup for AD and FTD. Patients with FTD are thought to have greater deficits in language and executive function while patients with AD are more likely to have deficits in memory. To determine if performance on initial cognitive testing can reliably distinguish between patients with frontotemporal lobar degeneration (FTLD) and AD neuropathology. In addition, are there other factors of the neuropsychological assessment that can be used to enhance the accuracy of underlying pathology? Using a logistic regression we retrospectively compared neurocognitive performance on initial evaluation of 106 patients with pathologically verified FTLD (pvFTLD), with 558 pathologically verified AD (pvAD) patients from the National Alzheimer's Coordinating Center using data from the Uniform Data Set (UDS) and the neuropathology data set. As expected, pvFTLD patients were younger, demonstrated better memory performance, and had more neuropsychiatric symptoms than pvAD patients. Other results were less predictable: pvFTLD patients performed better on one test of executive function (trail making test part B) but worse on another (digit span backward). Performance on language testing did not strongly distinguish the 2 groups. To determine what factors led to a misdiagnosis of AD in patients with FTLD, we further analyzed a small group of pvFTLD patients. These patients demonstrated older age and lower Neuropsychiatric Inventory Questionnaire counts compared with accurately diagnosed cases. Other than memory, numerical scores of neurocognitive performance on the UDS are of limited value in differentiating FTLD from AD at the initial visit. These results highlight the difficulty of obtaining an accurate early diagnosis of FTLD and argue for adding supplemental tests to those included in the UDS to assess cognition in FTD and AD patients.
NASA Astrophysics Data System (ADS)
Zhang, Ruiyun; Xu, Shisen; Cheng, Jian; Wang, Hongjian; Ren, Yongqiang
2017-07-01
Low-cost and high-performance matrix materials used in mass production of molten carbonate fuel cell (MCFC) were prepared by automatic casting machine with α-LiAlO2 powder material synthesized by gel-solid method, and distilled water as solvent. The single cell was assembled for generating test, and the good performance of the matrix was verified. The paper analyzed the factors affecting aqueous tape casting matrix preparation, such as solvent content, dispersant content, milling time, blade height and casting machine running speed, providing a solid basis for the mass production of large area environment-friendly matrix used in molten carbonate fuel cell.
[Model for unplanned self extubation of ICU patients using system dynamics approach].
Song, Yu Gil; Yun, Eun Kyoung
2015-04-01
In this study a system dynamics methodology was used to identify correlation and nonlinear feedback structure among factors affecting unplanned extubation (UE) of ICU patients and to construct and verify a simulation model. Factors affecting UE were identified through a theoretical background established by reviewing literature and preceding studies and referencing various statistical data. Related variables were decided through verification of content validity by an expert group. A causal loop diagram (CLD) was made based on the variables. Stock & Flow modeling using Vensim PLE Plus Version 6.0 b was performed to establish a model for UE. Based on the literature review and expert verification, 18 variables associated with UE were identified and CLD was prepared. From the prepared CLD, a model was developed by converting to the Stock & Flow Diagram. Results of the simulation showed that patient stress, patient in an agitated state, restraint application, patient movability, and individual intensive nursing were variables giving the greatest effect to UE probability. To verify agreement of the UE model with real situations, simulation with 5 cases was performed. Equation check and sensitivity analysis on TIME STEP were executed to validate model integrity. Results show that identification of a proper model enables prediction of UE probability. This prediction allows for adjustment of related factors, and provides basic data do develop nursing interventions to decrease UE.
40 CFR 63.2994 - How do I verify the performance of monitoring equipment?
Code of Federal Regulations, 2010 CFR
2010-07-01
... monitoring equipment. (2) Conduct a performance evaluation of the continuous monitoring system (CMS...-specific performance evaluation plan, conduct of the performance evaluation, and reporting of performance... 40 Protection of Environment 12 2010-07-01 2010-07-01 true How do I verify the performance of...
An urban energy performance evaluation system and its computer implementation.
Wang, Lei; Yuan, Guan; Long, Ruyin; Chen, Hong
2017-12-15
To improve the urban environment and effectively reflect and promote urban energy performance, an urban energy performance evaluation system was constructed, thereby strengthening urban environmental management capabilities. From the perspectives of internalization and externalization, a framework of evaluation indicators and key factors that determine urban energy performance and explore the reasons for differences in performance was proposed according to established theory and previous studies. Using the improved stochastic frontier analysis method, an urban energy performance evaluation and factor analysis model was built that brings performance evaluation and factor analysis into the same stage for study. According to data obtained for the Chinese provincial capitals from 2004 to 2013, the coefficients of the evaluation indicators and key factors were calculated by the urban energy performance evaluation and factor analysis model. These coefficients were then used to compile the program file. The urban energy performance evaluation system developed in this study was designed in three parts: a database, a distributed component server, and a human-machine interface. Its functions were designed as login, addition, edit, input, calculation, analysis, comparison, inquiry, and export. On the basis of these contents, an urban energy performance evaluation system was developed using Microsoft Visual Studio .NET 2015. The system can effectively reflect the status of and any changes in urban energy performance. Beijing was considered as an example to conduct an empirical study, which further verified the applicability and convenience of this evaluation system. Copyright © 2017 Elsevier Ltd. All rights reserved.
A Novel Byte-Substitution Architecture for the AES Cryptosystem.
Hossain, Fakir Sharif; Ali, Md Liakot
2015-01-01
The performance of Advanced Encryption Standard (AES) mainly depends on speed, area and power. The S-box represents an important factor that affects the performance of AES on each of these factors. A number of techniques have been presented in the literature, which have attempted to improve the performance of the S-box byte-substitution. This paper proposes a new S-box architecture, defining it as ultra low power, robustly parallel and highly efficient in terms of area. The architecture is discussed for both CMOS and FPGA platforms, and the pipelined architecture of the proposed S-box is presented for further time savings and higher throughput along with higher hardware resources utilization. A performance analysis and comparison of the proposed architecture is also conducted with those achieved by the existing techniques. The results of the comparison verify the outperformance of the proposed architecture in terms of power, delay and size.
A Novel Byte-Substitution Architecture for the AES Cryptosystem
Hossain, Fakir Sharif; Ali, Md. Liakot
2015-01-01
The performance of Advanced Encryption Standard (AES) mainly depends on speed, area and power. The S-box represents an important factor that affects the performance of AES on each of these factors. A number of techniques have been presented in the literature, which have attempted to improve the performance of the S-box byte-substitution. This paper proposes a new S-box architecture, defining it as ultra low power, robustly parallel and highly efficient in terms of area. The architecture is discussed for both CMOS and FPGA platforms, and the pipelined architecture of the proposed S-box is presented for further time savings and higher throughput along with higher hardware resources utilization. A performance analysis and comparison of the proposed architecture is also conducted with those achieved by the existing techniques. The results of the comparison verify the outperformance of the proposed architecture in terms of power, delay and size. PMID:26491967
Kim, Byung Jin; Han, Ji Min; Kang, Jung Gyu; Rhee, Eun Jung; Kim, Bum Soo; Kang, Jin Ho
No study has reported the relationship between cotinine-verified and self-reported smoking status with metabolic syndrome (MetS). This study was performed to evaluate the relationship between urinary cotinine-verified and self-reported smoking status with MetS and determine the effects of unobserved smokers on MetS in Korean adults. A total of 116,094 individuals (66,875 men and 49,219 women) with mean age of 36.7 ± 6.8 years included in Kangbuk Samsung Health Study and Kangbuk Samsung Cohort Study between 2011 and 2013 who had urinary cotinine measurements were enrolled. Cotinine-verified current smoking was defined as urinary cotinine level of above 50 ng/mL. Unobserved smoking was defined as urinary cotinine level of above 50 ng/mL in self-reported never smokers. The overall prevalence rates of cotinine-verified current smokers and MetS were 22.9% and 10.5%, respectively. The misclassification rate to cotinine-verified current smokers among self-reported never smokers was 1.7%. A multivariate logistic regression model adjusted for variables with univariate relationship (model 1) showed that cotinine-verified current smokers significantly increased the odds ratio for MetS compared with cotinine-verified never smokers (odds ratio [95% confidence interval], 1.30 [1.23, 1.37]). Log-transformed cotinine levels were also associated with MetS (1.04 [1.03, 1.05]). However, the association was not significant in the previously mentioned model including the traditional 5 components of MetS (model 2). Unobserved smokers significantly increased the ORs for MetS in both model 1 (1.43 [1.23, 1.67]) and model 2 (1.57 [1.06, 2.33]). This study shows that unobserved smoking and cotinine-verified current smoking are associated with MetS but urinary cotinine could be 1 conditional factor that interacts with traditional MetS components. Copyright © 2017 National Lipid Association. Published by Elsevier Inc. All rights reserved.
Prediction of human adaptation and performance in underwater environments.
Colodro Plaza, Joaquín; Garcés de los Fayos Ruiz, Enrique J; López García, Juan J; Colodro Conde, Lucía
2014-01-01
Environmental stressors require the professional diver to undergo a complex process of psychophysiological adaptation in order to overcome the demands of an extreme environment and carry out effective and efficient work under water. The influence of cognitive and personality traits in predicting underwater performance and adaptation has been a common concern for diving psychology, and definitive conclusions have not been reached. In this ex post facto study, psychological and academic data were analyzed from a large sample of personnel participating in scuba diving courses carried out in the Spanish Navy Diving Center. In order to verify the relevance of individual differences in adaptation to a hostile environment, we evaluated the predictive validity of general mental ability and personality traits with regression techniques. The data indicated the existence of psychological variables that can predict the performance ( R² = .30, p <.001) and adaptation ( R²(N) = .51, p <.001) of divers in underwater environment. These findings support the hypothesis that individual differences are related to the probability of successful adaptation and effective performance in professional diving. These results also verify that dispositional traits play a decisive role in diving training and are significant factors in divers' psychological fitness.
Tsugawa, Yusuke; Ohbu, Sadayoshi; Cruess, Richard; Cruess, Sylvia; Okubo, Tomoya; Takahashi, Osamu; Tokuda, Yasuharu; Heist, Brian S; Bito, Seiji; Itoh, Toshiyuki; Aoki, Akiko; Chiba, Tsutomu; Fukui, Tsuguya
2011-08-01
Despite the growing importance of and interest in medical professionalism, there is no standardized tool for its measurement. The authors sought to verify the validity, reliability, and generalizability of the Professionalism Mini-Evaluation Exercise (P-MEX), a previously developed and tested tool, in the context of Japanese hospitals. A multicenter, cross-sectional evaluation study was performed to investigate the validity, reliability, and generalizability of the P-MEX in seven Japanese hospitals. In 2009-2010, 378 evaluators (attending physicians, nurses, peers, and junior residents) completed 360-degree assessments of 165 residents and fellows using the P-MEX. The content validity and criterion-related validity were examined, and the construct validity of the P-MEX was investigated by performing confirmatory factor analysis through a structural equation model. The reliability was tested using generalizability analysis. The contents of the P-MEX achieved good acceptance in a preliminary working group, and the poststudy survey revealed that 302 (79.9%) evaluators rated the P-MEX items as appropriate, indicating good content validity. The correlation coefficient between P-MEX scores and external criteria was 0.78 (P < .001), demonstrating good criterion-related validity. Confirmatory factor analysis verified high path coefficient (0.60-0.99) and adequate goodness of fit of the model. The generalizability analysis yielded a high dependability coefficient, suggesting good reliability, except when evaluators were peers or junior residents. Findings show evidence of adequate validity, reliability, and generalizability of the P-MEX in Japanese hospital settings. The P-MEX is the only evaluation tool for medical professionalism verified in both a Western and East Asian cultural context.
Vries, Minka J A; Bouman, Heleen J; Olie, Renske H; Veenstra, Leo F; Zwaveling, Suzanne; Verhezen, Paul W M; Ten Cate-Hoek, Arina J; Ten Cate, Hugo; Henskens, Yvonne M C; van der Meijden, Paola E J
2017-01-01
Therapeutic windows for residual platelet reactivity in patients with coronary artery disease on P2Y12 inhibitors were proposed in a consensus document. We aimed to explore the level of agreement between windows for different platelet function tests (PFTs) used to classify patients in low, optimal, and high on-treatment platelet reactivity categories, and to identify variables contributing to the level of agreement. In this explorative clinical study, the VerifyNow P2Y12, Multiplate adenosine diphosphate (ADP), and light transmission aggregometry (LTA) 20 μmol/L ADP were performed simultaneously in 145 consecutive vulnerable patients. Measurements were performed within 6 months of percutaneous intervention. Patients were considered vulnerable if they had ≥2 risk factors for bleeding or ischaemic events. Window-agreement between PFT pairs was slight to moderate. Multiplate-VerifyNow agreed in 72 patients (50%), κ = 0.41; VerifyNow-LTA agreed in 76 patients (52%), κ = 0.36; and LTA-Multiplate agreed in 64 patients (44%), κ = 0.20. Several variables including the type of P2Y12 inhibitor, aspirin, haemoglobin level, platelet count, age, and previous stroke significantly influenced agreement between PFTs. Our results suggest that the PFTs, with accompanying therapeutic windows, are not interchangeable when determining the response to antiplatelet therapy in vulnerable coronary artery disease patients on P2Y12 inhibitors. Hence, the type of PFT can directly affect the treatment strategy, which may be especially relevant for patients with multiple factors influencing individual PFTs and thereby test agreement. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For Permissions, please email: journals.permissions@oup.com.
Evaluating the beam quality of double-cladding fiber lasers in applications.
Yan, Ping; Wang, Xuejiao; Gong, Mali; Xiao, Qirong
2016-08-10
We put forward a new βFL factor, which is used exclusively in fiber lasers and is suitable to assess beam quality and choose the LP01 mode as the new suitable ideal beam. We present a new simple measurement method and verify the reasonability of the βFL factor in experiment in a 20/400 μm fiber laser. Furthermore, we use the βFL factor to evaluate the beam quality of a 3-kW-level fiber laser. It can be concluded that βFL is a key factor not only for assessing the performance of the high-power fiber laser that is our main focus, but also for the simple measurement.
Dispersive analysis of the pion transition form factor.
Hoferichter, M; Kubis, B; Leupold, S; Niecknig, F; Schneider, S P
We analyze the pion transition form factor using dispersion theory. We calculate the singly-virtual form factor in the time-like region based on data for the [Formula: see text] cross section, generalizing previous studies on [Formula: see text] decays and [Formula: see text] scattering, and verify our result by comparing to [Formula: see text] data. We perform the analytic continuation to the space-like region, predicting the poorly-constrained space-like transition form factor below [Formula: see text], and extract the slope of the form factor at vanishing momentum transfer [Formula: see text]. We derive the dispersive formalism necessary for the extension of these results to the doubly-virtual case, as required for the pion-pole contribution to hadronic light-by-light scattering in the anomalous magnetic moment of the muon.
Yu, Yong-Jie; Wu, Hai-Long; Fu, Hai-Yan; Zhao, Juan; Li, Yuan-Na; Li, Shu-Fang; Kang, Chao; Yu, Ru-Qin
2013-08-09
Chromatographic background drift correction has been an important field of research in chromatographic analysis. In the present work, orthogonal spectral space projection for background drift correction of three-dimensional chromatographic data was described in detail and combined with parallel factor analysis (PARAFAC) to resolve overlapped chromatographic peaks and obtain the second-order advantage. This strategy was verified by simulated chromatographic data and afforded significant improvement in quantitative results. Finally, this strategy was successfully utilized to quantify eleven antibiotics in tap water samples. Compared with the traditional methodology of introducing excessive factors for the PARAFAC model to eliminate the effect of background drift, clear improvement in the quantitative performance of PARAFAC was observed after background drift correction by orthogonal spectral space projection. Copyright © 2013 Elsevier B.V. All rights reserved.
Air-kerma strength determination of a new directional (103)Pd source.
Aima, Manik; Reed, Joshua L; DeWerd, Larry A; Culberson, Wesley S
2015-12-01
A new directional (103)Pd planar source array called a CivaSheet™ has been developed by CivaTech Oncology, Inc., for potential use in low-dose-rate (LDR) brachytherapy treatments. The array consists of multiple individual polymer capsules called CivaDots, containing (103)Pd and a gold shield that attenuates the radiation on one side, thus defining a hot and cold side. This novel source requires new methods to establish a source strength metric. The presence of gold material in such close proximity to the active (103)Pd region causes the source spectrum to be significantly different than the energy spectra of seeds normally used in LDR brachytherapy treatments. In this investigation, the authors perform air-kerma strength (S(K)) measurements, develop new correction factors for these measurements based on an experimentally verified energy spectrum, and test the robustness of transferring S(K) to a well-type ionization chamber. S(K) measurements were performed with the variable-aperture free-air chamber (VAFAC) at the University of Wisconsin Medical Radiation Research Center. Subsequent measurements were then performed in a well-type ionization chamber. To realize the quantity S(K) from a directional source with gold material present, new methods and correction factors were considered. Updated correction factors were calculated using the MCNP 6 Monte Carlo code in order to determine S(K) with the presence of gold fluorescent energy lines. In addition to S(K) measurements, a low-energy high-purity germanium (HPGe) detector was used to experimentally verify the calculated spectrum, a sodium iodide (NaI) scintillating counter was used to verify the azimuthal and polar anisotropy, and a well-type ionization chamber was used to test the feasibility of disseminating S(K) values for a directional source within a cylindrically symmetric measurement volume. The UW VAFAC was successfully used to measure the S(K) of four CivaDots with reproducibilities within 0.3%. Monte Carlo methods were used to calculate the UW VAFAC correction factors and the calculated spectrum emitted from a CivaDot was experimentally verified with HPGe detector measurements. The well-type ionization chamber showed minimal variation in response (<1.5%) as a function of source positioning angle, indicating that an American Association of Physicists in Medicine (AAPM) Accredited Dosimetry Calibration Laboratory calibrated well chamber would be a suitable device to transfer an S(K)-based calibration to a clinical user. S(K) per well-chamber ionization current ratios were consistent among the four dots measured. Additionally, the measurements and predictions of anisotropy show uniform emission within the solid angle of the VAFAC, which demonstrates the robustness of the S(K) measurement approach. This characterization of a new (103)Pd directional brachytherapy source helps to establish calibration methods that could ultimately be used in the well-established AAPM Task Group 43 formalism. Monte Carlo methods accurately predict the changes in the energy spectrum caused by the fluorescent x-rays produced in the gold shield.
Air-kerma strength determination of a new directional 103Pd source
Reed, Joshua L.; DeWerd, Larry A.; Culberson, Wesley S.
2015-01-01
Purpose: A new directional 103Pd planar source array called a CivaSheet™ has been developed by CivaTech Oncology, Inc., for potential use in low-dose-rate (LDR) brachytherapy treatments. The array consists of multiple individual polymer capsules called CivaDots, containing 103Pd and a gold shield that attenuates the radiation on one side, thus defining a hot and cold side. This novel source requires new methods to establish a source strength metric. The presence of gold material in such close proximity to the active 103Pd region causes the source spectrum to be significantly different than the energy spectra of seeds normally used in LDR brachytherapy treatments. In this investigation, the authors perform air-kerma strength (SK) measurements, develop new correction factors for these measurements based on an experimentally verified energy spectrum, and test the robustness of transferring SK to a well-type ionization chamber. Methods: SK measurements were performed with the variable-aperture free-air chamber (VAFAC) at the University of Wisconsin Medical Radiation Research Center. Subsequent measurements were then performed in a well-type ionization chamber. To realize the quantity SK from a directional source with gold material present, new methods and correction factors were considered. Updated correction factors were calculated using the mcnp 6 Monte Carlo code in order to determine SK with the presence of gold fluorescent energy lines. In addition to SK measurements, a low-energy high-purity germanium (HPGe) detector was used to experimentally verify the calculated spectrum, a sodium iodide (NaI) scintillating counter was used to verify the azimuthal and polar anisotropy, and a well-type ionization chamber was used to test the feasibility of disseminating SK values for a directional source within a cylindrically symmetric measurement volume. Results: The UW VAFAC was successfully used to measure the SK of four CivaDots with reproducibilities within 0.3%. Monte Carlo methods were used to calculate the UW VAFAC correction factors and the calculated spectrum emitted from a CivaDot was experimentally verified with HPGe detector measurements. The well-type ionization chamber showed minimal variation in response (<1.5%) as a function of source positioning angle, indicating that an American Association of Physicists in Medicine (AAPM) Accredited Dosimetry Calibration Laboratory calibrated well chamber would be a suitable device to transfer an SK-based calibration to a clinical user. SK per well-chamber ionization current ratios were consistent among the four dots measured. Additionally, the measurements and predictions of anisotropy show uniform emission within the solid angle of the VAFAC, which demonstrates the robustness of the SK measurement approach. Conclusions: This characterization of a new 103Pd directional brachytherapy source helps to establish calibration methods that could ultimately be used in the well-established AAPM Task Group 43 formalism. Monte Carlo methods accurately predict the changes in the energy spectrum caused by the fluorescent x-rays produced in the gold shield. PMID:26632069
Epistemic belief structures within introductory astronomy
NASA Astrophysics Data System (ADS)
Johnson, Keith; Willoughby, Shannon D.
2018-06-01
The reliability and validity of inventories should be verified in multiple ways. Although the epistemological beliefs about the physical science survey (EBAPS) has been deemed to be reliable and valid by the authors, the axes or factor structure proposed by the authors has not been independently checked. Using data from a study sample we discussed in previous publications, we performed exploratory factor analysis on 1,258 post-test EBAPS surveys. The students in the sample were from an introductory Astronomy course at a mid-sized western university. Inspection suggested the use of either a three-factor model or a five-factor model. Each of the factors is interpreted and discussed, and the factors are compared to the axes proposed by the authors of the EBAPS. We find that the five-factor model extrapolated from our data partially overlaps with the model put forth by the authors of the EBAPS, and that many of the questions did not load onto any factors.
NASA LeRC's Acoustic Fill Effect Test Program and Results
NASA Technical Reports Server (NTRS)
Hughes, William O.; Mcnelis, Mark E.; Manning, Jerome E.
1994-01-01
NASA Lewis Research Center, in conjunction with General Dynamics Space Systems Division, has performed a test program to investigate the acoustic fill effect for an unblanketed payload fairing for a variety of payload simulators. This paper will discuss this test program and fill factor test data, and make comparisons with theoretical predictions. This paper will also address the NASA acoustic fill effect standard which was verified from the test data analysis.
NASA Astrophysics Data System (ADS)
Azadeh, A.; Foroozan, H.; Ashjari, B.; Motevali Haghighi, S.; Yazdanparast, R.; Saberi, M.; Torki Nejad, M.
2017-10-01
ISs and ITs play a critical role in large complex gas corporations. Many factors such as human, organisational and environmental factors affect IS in an organisation. Therefore, investigating ISs success is considered to be a complex problem. Also, because of the competitive business environment and the high amount of information flow in organisations, new issues like resilient ISs and successful customer relationship management (CRM) have emerged. A resilient IS will provide sustainable delivery of information to internal and external customers. This paper presents an integrated approach to enhance and optimise the performance of each component of a large IS based on CRM and resilience engineering (RE) in a gas company. The enhancement of the performance can help ISs to perform business tasks efficiently. The data are collected from standard questionnaires. It is then analysed by data envelopment analysis by selecting the optimal mathematical programming approach. The selected model is validated and verified by principle component analysis method. Finally, CRM and RE factors are identified as influential factors through sensitivity analysis for this particular case study. To the best of our knowledge, this is the first study for performance assessment and optimisation of large IS by combined RE and CRM.
PDSS/IMC qualification test software acceptance procedures
NASA Technical Reports Server (NTRS)
1984-01-01
Tests to be performed for qualifying the payload development support system image motion compensator (IMC) are identified. The performance of these tests will verify the IMC interfaces and thereby verify the qualification test software.
Song, Rhayun; Oh, Hyunkyoung; Ahn, Sukhee; Moorhead, Sue
2018-02-01
The purpose of this study was to validate the Cardiac Health Behavior Scale for Korean adults (CHB-K) to determine its validity and reliability. Cardiovascular diseases (CVDs) are one of the most important chronic diseases due to their high prevalence and mortality rates. Patients with cardiovascular risks or diseases need to perform appropriate cardiac health behaviors that help to prevent the progression of the disease and improve their health status. This secondary analysis obtained data from two clinical trials of cardiac rehabilitation. Data from 298 patients with cardiovascular risks or diseases were analyzed for validation. Data analyses included correlation coefficients, t-tests, and exploratory and confirmatory factor analyses using SPSS (version WIN 22.0) and AMOS (version 20.0). The Self-Efficacy Scale was used to assess convergent validity, while reliability was assessed using Cronbach's alpha coefficients. Five main factors were verified: health responsibility, physical activity, diet habit (eating habit and food choice), stress management, and smoking cessation. A set of 21 items from the 25-item scale was verified after performing item analysis, factor analyses, and critical evaluation of the statistical results. The 21-item CHB-K (CHB-K21) exhibited acceptable validity, and the model of the CHB-K21 provided a good fit to the data. Most of the factors were found to be moderately correlated with SES scores (r=0.45-0.52, p<0.001). The CHB-K21 also demonstrated acceptable reliability (Cronbach's alpha=0.83). The CHB-K21 demonstrates strong validity and reliability. It can be used to assess cardiac health behaviors in Korean adults with cardiovascular risks or diseases. Copyright © 2017 Elsevier Inc. All rights reserved.
Validation of Test Methods for Air Leak Rate Verification of Spaceflight Hardware
NASA Technical Reports Server (NTRS)
Oravec, Heather Ann; Daniels, Christopher C.; Mather, Janice L.
2017-01-01
As deep space exploration continues to be the goal of NASAs human spaceflight program, verification of the performance of spaceflight hardware becomes increasingly critical. Suitable test methods for verifying the leak rate of sealing systems are identified in program qualification testing requirements. One acceptable method for verifying the air leak rate of gas pressure seals is the tracer gas leak detector method. In this method, a tracer gas (commonly helium) leaks past the test seal and is transported to the leak detector where the leak rate is quantified. To predict the air leak rate, a conversion factor of helium-to-air is applied depending on the magnitude of the helium flow rate. The conversion factor is based on either the molecular mass ratio or the ratio of the dynamic viscosities. The current work was aimed at validating this approach for permeation-level leak rates using a series of tests with a silicone elastomer O-ring. An established pressure decay method with constant differential pressure was used to evaluate both the air and helium leak rates of the O-ring under similar temperature and pressure conditions. The results from the pressure decay tests showed, for the elastomer O-ring, that neither the molecular flow nor the viscous flow helium-to-air conversion factors were applicable. Leak rate tests were also performed using nitrogen and argon as the test gas. Molecular mass and viscosity based helium-to-test gas conversion factors were applied, but did not correctly predict the measured leak rates of either gas. To further this study, the effect of pressure boundary conditions was investigated. Often, pressure decay leak rate tests are performed at a differential pressure of 101.3 kPa with atmospheric pressure on the downstream side of the test seal. In space applications, the differential pressure is similar, but with vacuum as the downstream pressure. The same O-ring was tested at four unique differential pressures ranging from 34.5 to 137.9 kPa. Up to six combinations of upstream and downstream pressures for each differential pressure were compared. For a given differential pressure, the various combinations of upstream and downstream dry air pressures did not significantly affect the leak rate. As expected, the leak rate of the O-ring increased with increasing differential pressure. The results suggested that the current leak test pressure conditions, used to verify spacecraft sealing systems with elastomer seals, produce accurate values even though the boundary conditions do not model the space application.
NASA Technical Reports Server (NTRS)
Hilburger, Mark W.; Waters, W. Allen, Jr.; Haynie, Waddy T.; Thornburgh, Robert P
2017-01-01
Results from the testing of cylinder test article SBKF-P2-CYL-TA02 (referred to herein as TA02) are presented. TA02 is an 8-foot-diameter (96-inches), 78.0-inch-long, aluminum-lithium (Al-Li), orthogrid-stiffened cylindrical shell similar to those used in current state-of-the-art launch-vehicle structures and was designed to exhibit global buckling when subjected to combined compression and bending loads. The testing was conducted at the Marshall Space Flight Center (MSFC), February 3-6, 2009, in support of the Shell Buckling Knockdown Factor Project (SBKF). The test was used to verify the performance of a newly constructed buckling test facility at MSFC and to verify the test article design and analysis approach used by the SBKF researchers.
[The development and evaluation of software to verify diagnostic accuracy].
Jensen, Rodrigo; de Moraes Lopes, Maria Helena Baena; Silveira, Paulo Sérgio Panse; Ortega, Neli Regina Siqueira
2012-02-01
This article describes the development and evaluation of software that verifies the accuracy of diagnoses made by nursing students. The software was based on a model that uses fuzzy logic concepts, including PERL, the MySQL database for Internet accessibility, and the NANDA-I 2007-2008 classification system. The software was evaluated in terms of its technical quality and usability through specific instruments. The activity proposed in the software involves four stages in which students establish the relationship values between nursing diagnoses, defining characteristics/risk factors and clinical cases. The relationship values determined by students are compared to those of specialists, generating performance scores for the students. In the evaluation, the software demonstrated satisfactory outcomes regarding the technical quality and, according to the students, helped in their learning and may become an educational tool to teach the process of nursing diagnosis.
Optimal Verification of Entangled States with Local Measurements
NASA Astrophysics Data System (ADS)
Pallister, Sam; Linden, Noah; Montanaro, Ashley
2018-04-01
Consider the task of verifying that a given quantum device, designed to produce a particular entangled state, does indeed produce that state. One natural approach would be to characterize the output state by quantum state tomography, or alternatively, to perform some kind of Bell test, tailored to the state of interest. We show here that neither approach is optimal among local verification strategies for 2-qubit states. We find the optimal strategy in this case and show that quadratically fewer total measurements are needed to verify to within a given fidelity than in published results for quantum state tomography, Bell test, or fidelity estimation protocols. We also give efficient verification protocols for any stabilizer state. Additionally, we show that requiring that the strategy be constructed from local, nonadaptive, and noncollective measurements only incurs a constant-factor penalty over a strategy without these restrictions.
Appraising the value of independent EIA follow-up verifiers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wessels, Jan-Albert, E-mail: janalbert.wessels@nwu.ac.za; Retief, Francois, E-mail: francois.retief@nwu.ac.za; Morrison-Saunders, Angus, E-mail: A.Morrison-Saunders@murdoch.edu.au
Independent Environmental Impact Assessment (EIA) follow-up verifiers such as monitoring agencies, checkers, supervisors and control officers are active on various construction sites across the world. There are, however, differing views on the value that these verifiers add and very limited learning in EIA has been drawn from independent verifiers. This paper aims to appraise how and to what extent independent EIA follow-up verifiers add value in major construction projects in the developing country context of South Africa. A framework for appraising the role of independent verifiers was established and four South African case studies were examined through a mixture ofmore » site visits, project document analysis, and interviews. Appraisal results were documented in the performance areas of: planning, doing, checking, acting, public participating and integration with other programs. The results indicate that independent verifiers add most value to major construction projects when involved with screening EIA requirements of new projects, allocation of financial and human resources, checking legal compliance, influencing implementation, reporting conformance results, community and stakeholder engagement, integration with self-responsibility programs such as environmental management systems (EMS), and controlling records. It was apparent that verifiers could be more creatively utilized in pre-construction preparation, providing feedback of knowledge into assessment of new projects, giving input to the planning and design phase of projects, and performance evaluation. The study confirms the benefits of proponent and regulator follow-up, specifically in having independent verifiers that disclose information, facilitate discussion among stakeholders, are adaptable and proactive, aid in the integration of EIA with other programs, and instill trust in EIA enforcement by conformance evaluation. Overall, the study provides insight on how to harness the learning opportunities arising from EIA follow-up through the appointment of independent verifiers. - Highlights: • A framework for appraising the role of independent verifiers is established. • The value added to EIA follow-up by independent verifiers in South Africa is documented. • Verifiers add most value when involved with screening, checking compliance, influencing decisions and community engagement. • Verifiers could be more creatively utilized in pre-construction preparation, giving feedback, and performance evaluation.« less
Verifying Ballast Water Treatment Performance
The U.S. Environmental Protection Agency, NSF International, Battelle, and U.S. Coast Guard are jointly developing a protocol for verifying the technical performance of commercially available technologies designed to treat ship ballast water for potentially invasive species. The...
EMQIT: a machine learning approach for energy based PWM matrix quality improvement.
Smolinska, Karolina; Pacholczyk, Marcin
2017-08-01
Transcription factor binding affinities to DNA play a key role for the gene regulation. Learning the specificity of the mechanisms of binding TFs to DNA is important both to experimentalists and theoreticians. With the development of high-throughput methods such as, e.g., ChiP-seq the need to provide unbiased models of binding events has been made apparent. We present EMQIT a modification to the approach introduced by Alamanova et al. and later implemented as 3DTF server. We observed that tuning of Boltzmann factor weights, used for conversion of calculated energies to nucleotide probabilities, has a significant impact on the quality of the associated PWM matrix. Consequently, we proposed to use receiver operator characteristics curves and the 10-fold cross-validation to learn best weights using experimentally verified data from TRANSFAC database. We applied our method to data available for various TFs. We verified the efficiency of detecting TF binding sites by the 3DTF matrices improved with our technique using experimental data from the TRANSFAC database. The comparison showed a significant similarity and comparable performance between the improved and the experimental matrices (TRANSFAC). Improved 3DTF matrices achieved significantly higher AUC values than the original 3DTF matrices (at least by 0.1) and, at the same time, detected notably more experimentally verified TFBSs. The resulting new improved PWM matrices for analyzed factors show similarity to TRANSFAC matrices. Matrices had comparable predictive capabilities. Moreover, improved PWMs achieve better results than matrices downloaded from 3DTF server. Presented approach is general and applicable to any energy-based matrices. EMQIT is available online at http://biosolvers.polsl.pl:3838/emqit . This article was reviewed by Oliviero Carugo, Marek Kimmel and István Simon.
NASA Technical Reports Server (NTRS)
Hsia, Wei Shen
1989-01-01
A validated technology data base is being developed in the areas of control/structures interaction, deployment dynamics, and system performance for Large Space Structures (LSS). A Ground Facility (GF), in which the dynamics and control systems being considered for LSS applications can be verified, was designed and built. One of the important aspects of the GF is to verify the analytical model for the control system design. The procedure is to describe the control system mathematically as well as possible, then to perform tests on the control system, and finally to factor those results into the mathematical model. The reduction of the order of a higher order control plant was addressed. The computer program was improved for the maximum entropy principle adopted in Hyland's MEOP method. The program was tested against the testing problem. It resulted in a very close match. Two methods of model reduction were examined: Wilson's model reduction method and Hyland's optimal projection (OP) method. Design of a computer program for Hyland's OP method was attempted. Due to the difficulty encountered at the stage where a special matrix factorization technique is needed in order to obtain the required projection matrix, the program was successful up to the finding of the Linear Quadratic Gaussian solution but not beyond. Numerical results along with computer programs which employed ORACLS are presented.
Location-assured, multifactor authentication on smartphones via LTE communication
NASA Astrophysics Data System (ADS)
Kuseler, Torben; Lami, Ihsan A.; Al-Assam, Hisham
2013-05-01
With the added security provided by LTE, geographical location has become an important factor for authentication to enhance the security of remote client authentication during mCommerce applications using Smartphones. Tight combination of geographical location with classic authentication factors like PINs/Biometrics in a real-time, remote verification scheme over the LTE layer connection assures the authenticator about the client itself (via PIN/biometric) as well as the client's current location, thus defines the important aspects of "who", "when", and "where" of the authentication attempt without eaves dropping or man on the middle attacks. To securely integrate location as an authentication factor into the remote authentication scheme, client's location must be verified independently, i.e. the authenticator should not solely rely on the location determined on and reported by the client's Smartphone. The latest wireless data communication technology for mobile phones (4G LTE, Long-Term Evolution), recently being rolled out in various networks, can be employed to enhance this location-factor requirement of independent location verification. LTE's Control Plane LBS provisions, when integrated with user-based authentication and independent source of localisation factors ensures secure efficient, continuous location tracking of the Smartphone. This feature can be performed during normal operation of the LTE-based communication between client and network operator resulting in the authenticator being able to verify the client's claimed location more securely and accurately. Trials and experiments show that such algorithm implementation is viable for nowadays Smartphone-based banking via LTE communication.
Rajagopalan, S. P.
2017-01-01
Certificateless-based signcryption overcomes inherent shortcomings in traditional Public Key Infrastructure (PKI) and Key Escrow problem. It imparts efficient methods to design PKIs with public verifiability and cipher text authenticity with minimum dependency. As a classic primitive in public key cryptography, signcryption performs validity of cipher text without decryption by combining authentication, confidentiality, public verifiability and cipher text authenticity much more efficiently than the traditional approach. In this paper, we first define a security model for certificateless-based signcryption called, Complex Conjugate Differential Integrated Factor (CC-DIF) scheme by introducing complex conjugates through introduction of the security parameter and improving secured message distribution rate. However, both partial private key and secret value changes with respect to time. To overcome this weakness, a new certificateless-based signcryption scheme is proposed by setting the private key through Differential (Diff) Equation using an Integration Factor (DiffEIF), minimizing computational cost and communication overhead. The scheme is therefore said to be proven secure (i.e. improving the secured message distributing rate) against certificateless access control and signcryption-based scheme. In addition, compared with the three other existing schemes, the CC-DIF scheme has the least computational cost and communication overhead for secured message communication in mobile network. PMID:29040290
Alagarsamy, Sumithra; Rajagopalan, S P
2017-01-01
Certificateless-based signcryption overcomes inherent shortcomings in traditional Public Key Infrastructure (PKI) and Key Escrow problem. It imparts efficient methods to design PKIs with public verifiability and cipher text authenticity with minimum dependency. As a classic primitive in public key cryptography, signcryption performs validity of cipher text without decryption by combining authentication, confidentiality, public verifiability and cipher text authenticity much more efficiently than the traditional approach. In this paper, we first define a security model for certificateless-based signcryption called, Complex Conjugate Differential Integrated Factor (CC-DIF) scheme by introducing complex conjugates through introduction of the security parameter and improving secured message distribution rate. However, both partial private key and secret value changes with respect to time. To overcome this weakness, a new certificateless-based signcryption scheme is proposed by setting the private key through Differential (Diff) Equation using an Integration Factor (DiffEIF), minimizing computational cost and communication overhead. The scheme is therefore said to be proven secure (i.e. improving the secured message distributing rate) against certificateless access control and signcryption-based scheme. In addition, compared with the three other existing schemes, the CC-DIF scheme has the least computational cost and communication overhead for secured message communication in mobile network.
Critical Factors Analysis for Offshore Software Development Success by Structural Equation Modeling
NASA Astrophysics Data System (ADS)
Wada, Yoshihisa; Tsuji, Hiroshi
In order to analyze the success/failure factors in offshore software development service by the structural equation modeling, this paper proposes to follow two approaches together; domain knowledge based heuristic analysis and factor analysis based rational analysis. The former works for generating and verifying of hypothesis to find factors and causalities. The latter works for verifying factors introduced by theory to build the model without heuristics. Following the proposed combined approaches for the responses from skilled project managers of the questionnaire, this paper found that the vendor property has high causality for the success compared to software property and project property.
Simulation of existing gas-fuelled conventional steam power plant using Cycle Tempo
NASA Astrophysics Data System (ADS)
Jamel, M. S.; Abd Rahman, A.; Shamsuddin, A. H.
2013-06-01
Simulation of a 200 MW gas-fuelled conventional steam power plant located in Basra, Iraq was carried out. The thermodynamic performance of the considered power plant is estimated by a system simulation. A flow-sheet computer program, "Cycle-Tempo" is used for the study. The plant components and piping systems were considered and described in detail. The simulation results were verified against data gathered from the log sheet obtained from the station during its operation hours and good results were obtained. Operational factors like the stack exhaust temperature and excess air percentage were studied and discussed, as were environmental factors, such as ambient air temperature and water inlet temperature. In addition, detailed exergy losses were illustrated and describe the temperature profiles for the main plant components. The results prompted many suggestions for improvement of the plant performance.
A Novel Simple Phantom for Verifying the Dose of Radiation Therapy
Lee, J. H.; Chang, L. T.; Shiau, A. C.; Chen, C. W.; Liao, Y. J.; Li, W. J.; Lee, M. S.; Hsu, S. M.
2015-01-01
A standard protocol of dosimetric measurements is used by the organizations responsible for verifying that the doses delivered in radiation-therapy institutions are within authorized limits. This study evaluated a self-designed simple auditing phantom for use in verifying the dose of radiation therapy; the phantom design, dose audit system, and clinical tests are described. Thermoluminescent dosimeters (TLDs) were used as postal dosimeters, and mailable phantoms were produced for use in postal audits. Correction factors are important for converting TLD readout values from phantoms into the absorbed dose in water. The phantom scatter correction factor was used to quantify the difference in the scattered dose between a solid water phantom and homemade phantoms; its value ranged from 1.084 to 1.031. The energy-dependence correction factor was used to compare the TLD readout of the unit dose irradiated by audit beam energies with 60Co in the solid water phantom; its value was 0.99 to 1.01. The setup-condition factor was used to correct for differences in dose-output calibration conditions. Clinical tests of the device calibrating the dose output revealed that the dose deviation was within 3%. Therefore, our homemade phantoms and dosimetric system can be applied for accurately verifying the doses applied in radiation-therapy institutions. PMID:25883980
Air-kerma strength determination of a new directional {sup 103}Pd source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aima, Manik, E-mail: aima@wisc.edu; Reed, Joshua L.; DeWerd, Larry A.
2015-12-15
Purpose: A new directional {sup 103}Pd planar source array called a CivaSheet™ has been developed by CivaTech Oncology, Inc., for potential use in low-dose-rate (LDR) brachytherapy treatments. The array consists of multiple individual polymer capsules called CivaDots, containing {sup 103}Pd and a gold shield that attenuates the radiation on one side, thus defining a hot and cold side. This novel source requires new methods to establish a source strength metric. The presence of gold material in such close proximity to the active {sup 103}Pd region causes the source spectrum to be significantly different than the energy spectra of seeds normallymore » used in LDR brachytherapy treatments. In this investigation, the authors perform air-kerma strength (S{sub K}) measurements, develop new correction factors for these measurements based on an experimentally verified energy spectrum, and test the robustness of transferring S{sub K} to a well-type ionization chamber. Methods: S{sub K} measurements were performed with the variable-aperture free-air chamber (VAFAC) at the University of Wisconsin Medical Radiation Research Center. Subsequent measurements were then performed in a well-type ionization chamber. To realize the quantity S{sub K} from a directional source with gold material present, new methods and correction factors were considered. Updated correction factors were calculated using the MCNP 6 Monte Carlo code in order to determine S{sub K} with the presence of gold fluorescent energy lines. In addition to S{sub K} measurements, a low-energy high-purity germanium (HPGe) detector was used to experimentally verify the calculated spectrum, a sodium iodide (NaI) scintillating counter was used to verify the azimuthal and polar anisotropy, and a well-type ionization chamber was used to test the feasibility of disseminating S{sub K} values for a directional source within a cylindrically symmetric measurement volume. Results: The UW VAFAC was successfully used to measure the S{sub K} of four CivaDots with reproducibilities within 0.3%. Monte Carlo methods were used to calculate the UW VAFAC correction factors and the calculated spectrum emitted from a CivaDot was experimentally verified with HPGe detector measurements. The well-type ionization chamber showed minimal variation in response (<1.5%) as a function of source positioning angle, indicating that an American Association of Physicists in Medicine (AAPM) Accredited Dosimetry Calibration Laboratory calibrated well chamber would be a suitable device to transfer an S{sub K}-based calibration to a clinical user. S{sub K} per well-chamber ionization current ratios were consistent among the four dots measured. Additionally, the measurements and predictions of anisotropy show uniform emission within the solid angle of the VAFAC, which demonstrates the robustness of the S{sub K} measurement approach. Conclusions: This characterization of a new {sup 103}Pd directional brachytherapy source helps to establish calibration methods that could ultimately be used in the well-established AAPM Task Group 43 formalism. Monte Carlo methods accurately predict the changes in the energy spectrum caused by the fluorescent x-rays produced in the gold shield.« less
Adventure Behavior Seeking Scale
Próchniak, Piotr
2017-01-01
This article presents a new tool—the Adventure Behavior Seeking Scale (ABSS). The Adventure Behavior Seeking Scale was developed to assess individuals’ highly stimulating behaviors in natural environments. An exploratory factor analysis was conducted with 466 participants and resulted in one factor. The internal consistency was 0.80. A confirmatory factor analysis was performed using another sample of 406 participants, and results verified the one-factor structure. The findings indicate that people with a lot of experience in outdoor adventure have a higher score on the ABSS scale than control groups without such experience. The results also suggest that the 8-item ABSS scores were highly related to sensation seeking. The author discusses findings in regard to the ABSS as an instrument to measure outdoor adventure. However, further studies need to be carried out in other sample groups to further validate the scale. PMID:28555018
Fast parallel molecular algorithms for DNA-based computation: factoring integers.
Chang, Weng-Long; Guo, Minyi; Ho, Michael Shan-Hui
2005-06-01
The RSA public-key cryptosystem is an algorithm that converts input data to an unrecognizable encryption and converts the unrecognizable data back into its original decryption form. The security of the RSA public-key cryptosystem is based on the difficulty of factoring the product of two large prime numbers. This paper demonstrates to factor the product of two large prime numbers, and is a breakthrough in basic biological operations using a molecular computer. In order to achieve this, we propose three DNA-based algorithms for parallel subtractor, parallel comparator, and parallel modular arithmetic that formally verify our designed molecular solutions for factoring the product of two large prime numbers. Furthermore, this work indicates that the cryptosystems using public-key are perhaps insecure and also presents clear evidence of the ability of molecular computing to perform complicated mathematical operations.
Improving Reports Turnaround Time: An Essential Healthcare Quality Dimension.
Khan, Mustafa; Khalid, Parwaiz; Al-Said, Youssef; Cupler, Edward; Almorsy, Lamia; Khalifa, Mohamed
2016-01-01
Turnaround time is one of the most important healthcare performance indicators. King Faisal Specialist Hospital and Research Center in Jeddah, Saudi Arabia worked on reducing the reports turnaround time of the neurophysiology lab from more than two weeks to only five working days for 90% of cases. The main quality improvement methodology used was the FOCUS PDCA. Using root cause analysis, Pareto analysis and qualitative survey methods, the main factors contributing to the delay of turnaround time and the suggested improvement strategies were identified and implemented, through restructuring transcriptionists daily tasks, rescheduling physicians time and alerting for new reports, engaging consultants, consistent coordination and prioritizing critical reports. After implementation; 92% of reports are verified within 5 days compared to only 6% before implementation. 7% of reports were verified in 5 days to 2 weeks and only 1% of reports needed more than 2 weeks compared to 76% before implementation.
Design and Performance Investigation for the Optical Combinational Networks at High Data Rate
NASA Astrophysics Data System (ADS)
Tripathi, Devendra Kr.
2017-05-01
This article explores performance study for optical combinational designs based on nonlinear characteristics with semiconductor optical amplifier (SOA). Two configurations for optical half-adder with non-return-to-zero modulation pattern altogether with Mach-Zehnder modulator, interferometer at 50-Gbps data rate have been successfully realized. Accordingly, SUM and CARRY outputs have been concurrently executed and verified for their output waveforms. Numerical simulations for variation of data rate and key design parameters have been effectively executed outcome with optimum performance. Investigations depict overall good performance of the design in terms of the extinction factor. It also inferred that all-optical realization based on SOA is competent scheme, as it circumvents costly optoelectronic translation. This could be well supportive to erect larger complex optical combinational circuits.
Leadership: validation of a self-report scale.
Dussault, Marc; Frenette, Eric; Fernet, Claude
2013-04-01
The aim of this paper was to propose and test the factor structure of a new self-report questionnaire on leadership. A sample of 373 school principals in the Province of Quebec, Canada completed the initial 46-item version of the questionnaire. In order to obtain a questionnaire of minimal length, a four-step procedure was retained. First, items analysis was performed using Classical Test Theory. Second, Rasch analysis was used to identify non-fitting or overlapping items. Third, a confirmatory factor analysis (CFA) using structural equation modelling was performed on the 21 remaining items to verify the factor structure of the scale. Results show that the model with a single third-order dimension (leadership), two second-order dimensions (transactional and transformational leadership), and one first-order dimension (laissez-faire leadership) provides a good fit to the data. Finally, invariance of factor structure was assessed with a second sample of 222 vice-principals in the Province of Quebec, Canada. This model is in agreement with the theoretical model developed by Bass (1985), upon which the questionnaire is based.
Wafer hot spot identification through advanced photomask characterization techniques: part 2
NASA Astrophysics Data System (ADS)
Choi, Yohan; Green, Michael; Cho, Young; Ham, Young; Lin, Howard; Lan, Andy; Yang, Richer; Lung, Mike
2017-03-01
Historically, 1D metrics such as Mean to Target (MTT) and CD Uniformity (CDU) have been adequate for mask end users to evaluate and predict the mask impact on the wafer process. However, the wafer lithographer's process margin is shrinking at advanced nodes to a point that classical mask CD metrics are no longer adequate to gauge the mask contribution to wafer process error. For example, wafer CDU error at advanced nodes is impacted by mask factors such as 3-dimensional (3D) effects and mask pattern fidelity on sub-resolution assist features (SRAFs) used in Optical Proximity Correction (OPC) models of ever-increasing complexity. To overcome the limitation of 1D metrics, there are numerous on-going industry efforts to better define wafer-predictive metrics through both standard mask metrology and aerial CD methods. Even with these improvements, the industry continues to struggle to define useful correlative metrics that link the mask to final device performance. In part 1 of this work, we utilized advanced mask pattern characterization techniques to extract potential hot spots on the mask and link them, theoretically, to issues with final wafer performance. In this paper, part 2, we complete the work by verifying these techniques at wafer level. The test vehicle (TV) that was used for hot spot detection on the mask in part 1 will be used to expose wafers. The results will be used to verify the mask-level predictions. Finally, wafer performance with predicted and verified mask/wafer condition will be shown as the result of advanced mask characterization. The goal is to maximize mask end user yield through mask-wafer technology harmonization. This harmonization will provide the necessary feedback to determine optimum design, mask specifications, and mask-making conditions for optimal wafer process margin.
The expected results method for data verification
NASA Astrophysics Data System (ADS)
Monday, Paul
2016-05-01
The credibility of United States Army analytical experiments using distributed simulation depends on the quality of the simulation, the pedigree of the input data, and the appropriateness of the simulation system to the problem. The second of these factors is best met by using classified performance data from the Army Materiel Systems Analysis Activity (AMSAA) for essential battlefield behaviors, like sensors, weapon fire, and damage assessment. Until recently, using classified data has been a time-consuming and expensive endeavor: it requires significant technical expertise to load, and it is difficult to verify that it works correctly. Fortunately, new capabilities, tools, and processes are available that greatly reduce these costs. This paper will discuss these developments, a new method to verify that all of the components are configured and operate properly, and the application to recent Army Capabilities Integration Center (ARCIC) experiments. Recent developments have focused improving the process to load the data. OneSAF has redesigned their input data file formats and structures so that they correspond exactly with the Standard File Format (SFF) defined by AMSAA, ARCIC developed a library of supporting configurations that correlate directly to the AMSAA nomenclature, and the Entity Validation Tool was designed to quickly execute the essential models with a test-jig approach to identify problems with the loaded data. The missing part of the process is provided by the new Expected Results Method. Instead of the usual subjective assessment of quality, e.g., "It looks about right to me", this new approach compares the performance of a combat model with authoritative expectations to quickly verify that the model, data, and simulation are all working correctly. Integrated together, these developments now make it possible to use AMSAA classified performance data with minimal time and maximum assurance that the experiment's analytical results will be of the highest quality possible.
Scaled position-force tracking for wireless teleoperation of miniaturized surgical robotic system.
Guo, Jing; Liu, Chao; Poignet, Philippe
2014-01-01
Miniaturized surgical robotic system presents promising trend for reducing invasiveness during operation. However, cables used for power and communication may affect its performance. In this paper we chose Zigbee wireless communication as a means to replace communication cables for miniaturized surgical robot. Nevertheless, time delay caused by wireless communication presents a new challenge to performance and stability of the teleoperation system. We proposed a bilateral wireless teleoperation architecture taking into consideration of the effect of position-force scaling between operator and slave. Optimal position-force tracking performance is obtained and the overall system is shown to be passive with a simple condition on the scaling factors satisfied. Simulation studies verify the efficiency of the proposed scaled wireless teleoperation scheme.
NASA Astrophysics Data System (ADS)
Li, Jin; Qiu, Zhiling; Hu, Leilei
2018-04-01
The inverter-based regenerative braking power utilization devices can re-utilize the regenerative energy, thus reduce the energy consumption of urban rail transit. In this paper the power absorption principle of the inverter-based device is introduced, then the key influencing factors of energy saving performance are analyzed based on the absorption model. The field operation data verified that the control DC voltage plays an important role and lower control DC voltage yields more energy saving. Also, the one year energy saving performance data of an inverter-based re-utilization device located in NanJing S8 line is provided, and more than 1.2 million kWh energy is recovered in the one year operation.
NASA Astrophysics Data System (ADS)
Takahashi, D.; Sawaki, S.; Mu, R.-L.
2016-06-01
A new method for improving the sound insulation performance of double-glazed windows is proposed. This technique uses viscoelastic materials as connectors between the two glass panels to ensure that the appropriate spacing is maintained. An analytical model that makes it possible to discuss the effects of spacing, contact area, and viscoelastic properties of the connectors on the performance in terms of sound insulation is developed. The validity of the model is verified by comparing its results with measured data. The numerical experiments using this analytical model showed the importance of the ability of the connectors to achieve the appropriate spacing and their viscoelastic properties, both of which are necessary for improving the sound insulation performance. In addition, it was shown that the most effective factor is damping: the stronger the damping, the more the insulation performance increases.
[The prevalence of burnout and the related factors among some medical students in Korea].
Choi, Jaewon; Son, Shill Lee; Kim, Suh Hee; Kim, Hyunsoo; Hong, Jee-Young; Lee, Moo-Sik
2015-12-01
This study was conducted to examine the relationship between the prevalence of burnout and its related factors in medical students in Korea. All available medical students in the metropolitan city of Daejeon, Korea, were asked to answer self-administered questionnaires from July 1 to July 26 in 2013. A total of 534 medical students participated. The Maslach Burnout Inventory-Student Survey (MBI-SS) and structured questionnaires on related factors were used. Confirmatory factor analysis and Cronbach's α were used to verify the applicability of the MBI-SS to medical students in Korea. We also performed chi-square test and logistic regression analysis to identify the factors that were associated with burnout. The MBI-SS was reliable and valid in measuring burnout in Korean medical students. Our confirmatory factor analysis approved and explained the appropriateness of the model fit. The prevalence of burnout among medical students was 26.4% (n=141). Suchrates were higher in students who were female, experienced greater levels of depression, had poor academic performance, feared dropping out, and were stressed by the poor quality of the class facilities. The MBI-SS is a valid instrument to measure academic burnout in Korean medical students. Further studies should be performed, because improvements in the mental health of medical students will benefit these doctors-to-be and their future patients.
Flight motor set 36OH005 (STS-28R). Volume 5: (Nozzle component)
NASA Technical Reports Server (NTRS)
Smith, Dan M., Jr.
1990-01-01
A review of the performance and post flight condition of the STS-28 redesigned solid rocket motor (RSRM) nozzles is presented in this document. Applicable discrepancy reports (DR's) and process departures (PD's) are presented in section 5.0. The nozzle component program team (NCPT) performance evaluation and the redesign program review board (RPRB) assessment is included in section 6.0. The STS-28 nozzle assemblies were flown on the RSRM fifth flight (Space Shuttle Columbia). The nozzles were a partially submerged convergent/divergent movable design with an aft pivot point flexible bearing. The nozzle assemblies incorporated the following features: (1) RSRM forward exit cone with snubber assembly; (2) RSRM fixed housing; (3) structural backup outer boot ring (OBR); (4) RSRM cowl ring; (5) RSRM nose inlet assembly; (6) RSRM throat assembly; (7) RSRM forward nose and aft inlet ring; (8) RSRM aft exit cone assembly with linear-shaped charge (LSC); (9) RTV backfill in joints 1, 3, and 4; (10) use of EA913 NA adhesive in place of EA913; (11) redesigned nozzle plug; and (12) carbon cloth phenolic (CCP) with 750 ppm sodium content. The RSRM fifth flight test objectives are as follows: (1) verify that flexible bearing seals operate within the specified temperature range; (2) verify that flexible bearing maintained a positive gas seal between its internal components; (3) inspect flexible bearing for damage due to water impact; (4) verify performance of the nozzle liner; (5) verify that nozzle parts are reusable; (6) verify through flight demonstration and a postflight inspection that the flexible bearing is reusable; (7) verify by inspection the remaining nozzle ablative thicknesses; and (8) verify the nozzle performance margins of safety.
Recent technology products from Space Human Factors research
NASA Technical Reports Server (NTRS)
Jenkins, James P.
1991-01-01
The goals of the NASA Space Human Factors program and the research carried out concerning human factors are discussed with emphasis given to the development of human performance models, data, and tools. The major products from this program are described, which include the Laser Anthropometric Mapping System; a model of the human body for evaluating the kinematics and dynamics of human motion and strength in microgravity environment; an operational experience data base for verifying and validating the data repository of manned space flights; the Operational Experience Database Taxonomy; and a human-computer interaction laboratory whose products are the display softaware and requirements and the guideline documents and standards for applications on human-computer interaction. Special attention is given to the 'Convoltron', a prototype version of a signal processor for synthesizing the head-related transfer functions.
Bogdan, Anna; Sudoł-Szopińska, Iwona; Luczak, Anna; Konarska, Maria; Pietrowski, Piotr
2012-01-01
This article proposes a method for a comprehensive assessment of the effect of integral motorcycle helmets on physiological and cognitive responses of motorcyclists. To verify the reliability of commonly used tests, we conducted experiments with 5 motorcyclists. We recorded changes in physiological parameters (heart rate, local skin temperature, core temperature, air temperature, relative humidity in the space between the helmet and the surface of the head, and the concentration of O(2) and CO(2) under the helmet) and in psychological parameters (motorcyclists' reflexes, fatigue, perceptiveness and mood). We also studied changes in the motorcyclists' subjective sensation of thermal comfort. The results made it possible to identify reliable parameters for assessing the effect of integral helmets on performance, i.e., physiological factors (head skin temperature, internal temperature and concentration of O(2) and CO(2) under the helmet) and on psychomotor factors (reaction time, attention and vigilance, work performance, concentration and a subjective feeling of mood and fatigue).
Linnet, Karen Markussen; Wisborg, Kirsten; Secher, Niels Jørgen; Thomsen, Per Hove; Obel, Carsten; Dalsgaard, Søren; Henriksen, Tine Brink
2009-01-01
Based on hypotheses from experimental studies, we studied the association between intrauterine exposure to coffee and the risk of clinically verified hyperkinetic disorder and attention-deficit hyperactivity disorder (ADHD). A cohort study with prospectively collected data from the Aarhus Birth Cohort, Denmark. We included 24 068 singletons delivered between 1990 and 1998. Linkage was performed with three Danish longitudinal registers: The Danish Psychiatric Central Register, The Integrated Database for Labour Market Research and The Danish Civil Registration System. We identified 88 children with hyperkinetic disorder and ADHD. Information about coffee consumption during pregnancy was obtained at 16 weeks of gestation from self-administrated questionnaires. Potential confounding factors were evaluated using Cox regression analyses. We found that intrauterine exposure to 10 or more cups of coffee per day was associated with a threefold increased risk of hyperkinetic disorder and ADHD. After adjustments for a number of confounding factors, the risk decreased and became statistically insignificant (RR 2.3, 95% CI 0.9-5.9). Prenatal exposure to high levels of coffee did not significantly increase the risk of clinically verified hyperkinetic disorder and ADHD in childhood.
Equivalent parameter model of 1-3 piezocomposite with a sandwich polymer
NASA Astrophysics Data System (ADS)
Zhang, Yanjun; Wang, Likun; Qin, Lei
2018-06-01
A theoretical model was developed to investigate the performance of 1-3 piezoelectric composites with a sandwich polymer. Effective parameters, such as the electromechanical coupling factor, longitudinal velocity, and characteristic acoustic impedance of the piezocomposite, were predicted using the developed model. The influences of volume fractions and components of the polymer phase on the effective parameters of the piezoelectric composite were studied. The theoretical model was verified experimentally. The proposed model can reproduce the effective parameters of 1-3 piezoelectric composites with a sandwich polymer in the thickness mode. The measured electromechanical coupling factor was improved by more than 9.8% over the PZT/resin 1-3 piezoelectric composite.
47 CFR 73.151 - Field strength measurements to establish performance of directional antennas.
Code of Federal Regulations, 2010 CFR
2010-10-01
... verified either by field strength measurement or by computer modeling and sampling system verification. (a... specifically identified by the Commission. (c) Computer modeling and sample system verification of modeled... performance verified by computer modeling and sample system verification. (1) A matrix of impedance...
2011-01-01
Background In today's dynamic health-care system, organizations such as hospitals are required to improve their performance for multiple stakeholders and deliver an integrated care that means to work effectively, be innovative and organize efficiently. Achieved goals and levels of quality can be successfully measured by a multidimensional approach like Balanced Scorecard (BSC). The aim of the study was to verify the opportunity to introduce BSC framework to measure performance in St. Anna University Hospital of Ferrara, applying it to the Clinical Laboratory Operative Unit in order to compare over time performance results and achievements of assigned targets. Methods In the first experience with BSC we distinguished four perspectives, according to Kaplan and Norton, identified Key Performance Areas and Key Performance Indicators, set standards and weights for each objective, collected data for all indicators, recognized cause-and-effect relationships in a strategic map. One year later we proceeded with the next data collection and analysed the preservation of framework aptitude to measure Operative Unit performance. In addition, we verified the ability to underline links between strategic actions belonging to different perspectives in producing outcomes changes. Results The BSC was found to be effective for underlining existing problems and identifying opportunities for improvements. The BSC also revealed the specific perspective contribution to overall performance enhancement. After time results comparison was possible depending on the selection of feasible and appropriate key performance indicators, which was occasionally limited by data collection problems. Conclusions The first use of BSC to compare performance at Operative Unit level, in course of time, suggested this framework can be successfully adopted for results measuring and revealing effective health factors, allowing health-care quality improvements. PMID:21586111
Lupi, Silvia; Verzola, Adriano; Carandina, Gianni; Salani, Manuela; Antonioli, Paola; Gregorio, Pasquale
2011-05-17
In today's dynamic health-care system, organizations such as hospitals are required to improve their performance for multiple stakeholders and deliver an integrated care that means to work effectively, be innovative and organize efficiently. Achieved goals and levels of quality can be successfully measured by a multidimensional approach like Balanced Scorecard (BSC). The aim of the study was to verify the opportunity to introduce BSC framework to measure performance in St. Anna University Hospital of Ferrara, applying it to the Clinical Laboratory Operative Unit in order to compare over time performance results and achievements of assigned targets. In the first experience with BSC we distinguished four perspectives, according to Kaplan and Norton, identified Key Performance Areas and Key Performance Indicators, set standards and weights for each objective, collected data for all indicators, recognized cause-and-effect relationships in a strategic map. One year later we proceeded with the next data collection and analysed the preservation of framework aptitude to measure Operative Unit performance. In addition, we verified the ability to underline links between strategic actions belonging to different perspectives in producing outcomes changes. The BSC was found to be effective for underlining existing problems and identifying opportunities for improvements. The BSC also revealed the specific perspective contribution to overall performance enhancement. After time results comparison was possible depending on the selection of feasible and appropriate key performance indicators, which was occasionally limited by data collection problems. The first use of BSC to compare performance at Operative Unit level, in course of time, suggested this framework can be successfully adopted for results measuring and revealing effective health factors, allowing health-care quality improvements.
Martinez Galan, Bryan S; Giolo de Carvalho, Flavia; Carvalho Santos, Priscila; Bucken Gobbi, Ronaldo; Kalva-Filho, Carlos; Papoti, Marcelo; Sanchez Silva, Adelino; Freitas, Ellen C
2017-07-25
The practice of prolonged exercise with high intensity, as seen in triathlon training, can cause physiological imbalances that might result in muscle fatigue, muscle damage and changes in systemic inflammatory response, thus reduce the athletes physical performance, therefore, both adequate total caloric and macronutrient intake also the use of a specific ergogenic aid, as taurine supplementation would be an alternative to prevent inflammation and muscle damage. In order to verify the effects of 8 weeks of taurine and chocolate milk supplementation, markers of muscle damage, inflammation, and aerobic capacity were quantified in triathletes. A double-blind, crossover, randomized study was conducted with 9 male long distance triathletes, aged 25-35 years. Supplementation of 3 g of taurine (TAU) or placebo (PLA) associated with 400 ml low fat chocolate milk was performed during an 8-week period. In order to verify the effects of the supplementation protocol markers of muscle damage as lactate dehydrogenase (LDH) and creatine kinase (CK), and inflammatory markers tumor necrosis factor-α (TNF-α) and interleukin-6 (IL-6) were quantified, also triathletes performance was evaluated by exhaust test on a treadmill. It was observed a significant increase in taurine and CK plasma levels after TAU supplementation (p=0.02 and p=0.01, respectively). However, LDH concentrations did not differ significantly after the supplementations performed, and there were no changes in physical performance parameters; anaerobic threshold, perceived exertion, heart rate, and the concentrations of IL-6 and TNF-α. Taurine supplementation did not provide benefits on performance and muscle damage in triathletes.
Enhanced sensitivity in a butterfly gyroscope with a hexagonal oblique beam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xiao, Dingbang; Cao, Shijie; Hou, Zhanqiang, E-mail: houzhanqiang@nudt.edu.cn
2015-04-15
A new approach to improve the performance of a butterfly gyroscope is developed. The methodology provides a simple way to improve the gyroscope’s sensitivity and stability, by reducing the resonant frequency mismatch between the drive and sense modes. This method was verified by simulations and theoretical analysis. The size of the hexagonal section oblique beam is the major factor that influences the resonant frequency mismatch. A prototype, which has the appropriately sized oblique beam, was fabricated using precise, time-controlled multilayer pre-buried masks. The performance of this prototype was compared with a non-tuned gyroscope. The scale factor of the prototype reachesmore » 30.13 mV/ °/s, which is 15 times larger than that obtained from the non-tuned gyroscope. The bias stability of the prototype is 0.8 °/h, which is better than the 5.2 °/h of the non-tuned devices.« less
Eaton, Jennifer L; Mohr, David C; Hodgson, Michael J; McPhaul, Kathleen M
2018-02-01
To describe development and validation of the work-related well-being (WRWB) index. Principal components analysis was performed using Federal Employee Viewpoint Survey (FEVS) data (N = 392,752) to extract variables representing worker well-being constructs. Confirmatory factor analysis was performed to verify factor structure. To validate the WRWB index, we used multiple regression analysis to examine relationships with burnout associated outcomes. Principal Components Analysis identified three positive psychology constructs: "Work Positivity", "Co-worker Relationships", and "Work Mastery". An 11 item index explaining 63.5% of variance was achieved. The structural equation model provided a very good fit to the data. Higher WRWB scores were positively associated with all three employee experience measures examined in regression models. The new WRWB index shows promise as a valid and widely accessible instrument to assess worker well-being.
Eaton, Jennifer L; Mohr, David C; Hodgson, Michael J; McPhaul, Kathleen M
2017-10-11
To describe development and validation of the Work-Related Well-Being (WRWB) Index. Principal Components Analysis was performed using Federal Employee Viewpoint Survey (FEVS) data (N = 392,752) to extract variables representing worker well-being constructs. Confirmatory factor analysis was performed to verify factor structure. To validate the WRWB index, we used multiple regression analysis to examine relationships with burnout associated outcomes. PCA identified three positive psychology constructs: "Work Positivity", "Co-worker Relationships", and "Work Mastery". An 11 item index explaining 63.5% of variance was achieved. The structural equation model provided a very good fit to the data. Higher WRWB scores were positively associated with all 3 employee experience measures examined in regression models. The new WRWB index shows promise as a valid and widely accessible instrument to assess worker well-being.
A Thermoelastic Damping Model for the Cone Microcantilever Resonator with Circular Cross-section
NASA Astrophysics Data System (ADS)
Li, Pu; Zhou, Hongyue
2017-07-01
Microbeams with variable cross-section have been applied in Microelectromechanical Systems (MEMS) resonators. Quality factor (Q-factor) is an important factor evaluating the performance of MEMS resonators, and high Q-factor stands for the excellent performance. Thermoelastic damping (TED), which has been verified as a fundamental energy lost mechanism for microresonators, determines the upper limit of Q-factor. TED can be calculated by the Zener’s model and Lifshits and Roukes (LR) model. However, for microbeam resonators with variable cross-sections, these two models become invalid in some cases. In this work, we derived the TED model for cone microcantilever with circular cross-section that is a representative non-uniform microbeam. The comparison of results obtained by the present model and Finite Element Method (FEM) model proves that the present model is valid for predicting TED value for cone microcantilever with circular cross-section. The results suggest that the first-order natural frequencies and TED values of cone microcantilever are larger than those of uniform microbeam for large aspect ratios (l/r 0). In addition, the Debye peak value of a uniform microcantilever is equal to 0.5ΔE, while that of cone microcantilever is about 0.438ΔE.
A concordance index for matched case-control studies with applications in cancer risk.
Brentnall, Adam R; Cuzick, Jack; Field, John; Duffy, Stephen W
2015-02-10
In unmatched case-control studies, the area under the receiver operating characteristic (ROC) curve (AUC) may be used to measure how well a variable discriminates between cases and controls. The AUC is sometimes used in matched case-control studies by ignoring matching, but it lacks interpretation because it is not based on an estimate of the ROC for the population of interest. We introduce an alternative measure of discrimination that is the concordance of risk factors conditional on the matching factors. Parametric and non-parametric estimators are given for different matching scenarios, and applied to real data from breast and lung cancer case-control studies. Diagnostic plots to verify the constancy of discrimination over matching factors are demonstrated. The proposed simple measure is easy to use, interpret, more efficient than unmatched AUC statistics and may be applied to compare the conditional discrimination performance of risk factors. Copyright © 2014 John Wiley & Sons, Ltd.
Human posture in microgravity: An experiment on EUROMIR '95 to verify and improve a simulation tool
NASA Astrophysics Data System (ADS)
Colford, Nicholas; Giorgi, Pier Luigi; Gaia, Enrico; Cotronei, Vittorio
1995-10-01
An anthropometric mannequin implemented in robotic modelling software has proved very useful in the simulation of static and semi-dynamic reachability envelopes. Its prediction of working postures has been verified to some extent during neutral buoyancy trials. While a robotic solution is useful for static analyses or rough estimates of simple movements, more realistic movement strategies need to be identified directly measuring astronauts' in-orbit behaviour. A set of experiments is to be performed as part of the EUROMIR '95 mission to the MIR orbiting station in which dynamic posture (i.e. posture and movement) measurements will be taken using the ELITE system. The data and analyses of the data will be used to animate the Alenia anthopometric mannequin and to develop movement algorithms more similar to those of a person in microgravity than the robotic solutions currently employed. This paper presents the experiments to be performed and the changes to Alenia's mannequin that will allow the model to effect movements according to the experimental results. It is aimed at expanding the dialog between the biomechanical and human factors disciplines started in this experiment to other potential end-users of the experimental results.
Development of pulsating twin jets mechanism for mixing flow heat transfer analysis.
Gitan, Ali Ahmed; Zulkifli, Rozli; Abdullah, Shahrir; Sopian, Kamaruzzaman
2014-01-01
Pulsating twin jets mechanism (PTJM) was developed in the present work to study the effect of pulsating twin jets mixing region on the enhancement of heat transfer. Controllable characteristics twin pulsed jets were the main objective of our design. The variable nozzle-nozzle distance was considered to study the effect of two jets interaction at the mixing region. Also, the phase change between the frequencies of twin jets was taken into account to develop PTJM. All of these factors in addition to the ability of producing high velocity pulsed jet led to more appropriate design for a comprehensive study of multijet impingement heat transfer problems. The performance of PTJM was verified by measuring the pulse profile at frequency of 20 Hz, where equal velocity peak of around 64 m/s for both jets was obtained. Moreover, the jet velocity profile at different pulsation frequencies was tested to verify system performance, so the results revealed reasonable velocity profile configuration. Furthermore, the effect of pulsation frequency on surface temperature of flat hot plate in the midpoint between twin jets was studied experimentally. Noticeable enhancement in heat transfer was obtained with the increasing of pulsation frequency.
Development of Pulsating Twin Jets Mechanism for Mixing Flow Heat Transfer Analysis
Abdullah, Shahrir
2014-01-01
Pulsating twin jets mechanism (PTJM) was developed in the present work to study the effect of pulsating twin jets mixing region on the enhancement of heat transfer. Controllable characteristics twin pulsed jets were the main objective of our design. The variable nozzle-nozzle distance was considered to study the effect of two jets interaction at the mixing region. Also, the phase change between the frequencies of twin jets was taken into account to develop PTJM. All of these factors in addition to the ability of producing high velocity pulsed jet led to more appropriate design for a comprehensive study of multijet impingement heat transfer problems. The performance of PTJM was verified by measuring the pulse profile at frequency of 20 Hz, where equal velocity peak of around 64 m/s for both jets was obtained. Moreover, the jet velocity profile at different pulsation frequencies was tested to verify system performance, so the results revealed reasonable velocity profile configuration. Furthermore, the effect of pulsation frequency on surface temperature of flat hot plate in the midpoint between twin jets was studied experimentally. Noticeable enhancement in heat transfer was obtained with the increasing of pulsation frequency. PMID:24672370
Total systems design analysis of high performance structures
NASA Technical Reports Server (NTRS)
Verderaime, V.
1993-01-01
Designer-control parameters were identified at interdiscipline interfaces to optimize structural systems performance and downstream development and operations with reliability and least life-cycle cost. Interface tasks and iterations are tracked through a matrix of performance disciplines integration versus manufacturing, verification, and operations interactions for a total system design analysis. Performance integration tasks include shapes, sizes, environments, and materials. Integrity integrating tasks are reliability and recurring structural costs. Significant interface designer control parameters were noted as shapes, dimensions, probability range factors, and cost. Structural failure concept is presented, and first-order reliability and deterministic methods, benefits, and limitations are discussed. A deterministic reliability technique combining benefits of both is proposed for static structures which is also timely and economically verifiable. Though launch vehicle environments were primarily considered, the system design process is applicable to any surface system using its own unique filed environments.
Development of an algorithm to model an aircraft equipped with a generic CDTI display
NASA Technical Reports Server (NTRS)
Driscoll, W. C.; Houck, J. A.
1986-01-01
A model of human pilot performance of a tracking task using a generic Cockpit Display of Traffic Information (CDTI) display is developed from experimental data. The tracking task is to use CDTI in tracking a leading aircraft at a nominal separation of three nautical miles over a prescribed trajectory in space. The analysis of the data resulting from a factorial design of experiments reveals that the tracking task performance depends on the pilot and his experience at performing the task. Performance was not strongly affected by the type of control system used (velocity vector control wheel steering versus 3D automatic flight path guidance and control). The model that is developed and verified results in state trajectories whose difference from the experimental state trajectories is small compared to the variation due to the pilot and experience factors.
Strapdown system performance optimization test evaluations (SPOT), volume 1
NASA Technical Reports Server (NTRS)
Blaha, R. J.; Gilmore, J. P.
1973-01-01
A three axis inertial system was packaged in an Apollo gimbal fixture for fine grain evaluation of strapdown system performance in dynamic environments. These evaluations have provided information to assess the effectiveness of real-time compensation techniques and to study system performance tradeoffs to factors such as quantization and iteration rate. The strapdown performance and tradeoff studies conducted include: (1) Compensation models and techniques for the inertial instrument first-order error terms were developed and compensation effectivity was demonstrated in four basic environments; single and multi-axis slew, and single and multi-axis oscillatory. (2) The theoretical coning bandwidth for the first-order quaternion algorithm expansion was verified. (3) Gyro loop quantization was identified to affect proportionally the system attitude uncertainty. (4) Land navigation evaluations identified the requirement for accurate initialization alignment in order to pursue fine grain navigation evaluations.
RETScreen Plus Software Tutorial
NASA Technical Reports Server (NTRS)
Ganoe, Rene D.; Stackhouse, Paul W., Jr.; DeYoung, Russell J.
2014-01-01
Greater emphasis is being placed on reducing both the carbon footprint and energy cost of buildings. A building's energy usage depends upon many factors one of the most important is the local weather and climate conditions to which it's electrical, heating and air conditioning systems must respond. Incorporating renewable energy systems, including solar systems, to supplement energy supplies and increase energy efficiency is important to saving costs and reducing emissions. Also retrofitting technologies to buildings requires knowledge of building performance in its current state, potential future climate state, projection of potential savings with capital investment, and then monitoring the performance once the improvements are made. RETScreen Plus is a performance analysis software module that supplies the needed functions of monitoring current building performance, targeting projected energy efficiency improvements and verifying improvements once completed. This tutorial defines the functions of RETScreen Plus as well as outlines the general procedure for monitoring and reporting building energy performance.
A proposed standard round compact specimen for plane strain fracture toughness testing
NASA Technical Reports Server (NTRS)
Underwood, J. H.; Newman, J. C., Jr.; Seeley, R. R.
1980-01-01
A round, disk-shaped specimen is proposed as a standard test specimen for addition to ASTM Test for Plane-Strain Fracture Toughness of Metallic Materials (E 399-78A). The specimen is diametrically cracked, and loaded in the same way as the existing standard compact specimen. Tests and analyses were performed to verify that the proposed round compact specimen and associated stress intensity factor K solution are appropriate for a standard plane strain fracture toughness test. The use of the round compact specimen for other fracture tests is described.
Cycles till failure of silver-zinc cells with completing failures modes: Preliminary data analysis
NASA Technical Reports Server (NTRS)
Sidik, S. M.; Leibecki, H. F.; Bozek, J. M.
1980-01-01
One hundred and twenty nine cells were run through charge-discharge cycles until failure. The experiment design was a variant of a central composite factorial in five factors. Preliminary data analysis consisted of response surface estimation of life. Batteries fail under two basic modes; a low voltage condition and an internal shorting condition. A competing failure modes analysis using maximum likelihood estimation for the extreme value life distribution was performed. Extensive diagnostics such as residual plotting and probability plotting were employed to verify data quality and choice of model.
Rizzelli, Giuseppe; Iqbal, Md Asif; Gallazzi, Francesca; Rosa, Paweł; Tan, Mingming; Ania-Castañón, Juan Diego; Krzczanowicz, Lukasz; Corredera, Pedro; Phillips, Ian; Forysiak, Wladek; Harper, Paul
2016-12-12
Relative intensity noise transfer from the pump to the signal in 2nd-order ultra-long Raman laser amplifiers for telecommunications is characterized numerically and experimentally. Our results showcase the need for careful adjustment of the front FBG reflectivity and the relative contribution of forward pump power, and their impact on performance. Finally, our analysis is verified through a 10 × 30 GBaud DP-QPSK transmission experiment, showing a large Q factor penalty associated with the combination of high forward pumping and high reflectivities.
Van So, Pham; Jun, Hyun Woo; Lee, Jaichan
2013-12-01
We have investigated the actuator performance of a piezoelectrically actuated inkjet print head via the numerical and experimental analysis. The actuator consisting of multi-layer membranes, such as piezoelectric, elastic and other buffer layers, and ink chamber was fabricated by MEMS processing. The maximum displacement of the actuator membrane obtained in the experiment is explained by numerical analysis. A simulation of the actuator performance with fluidic damping shows that the resonant frequency of the membrane in liquid is reduced from its resonant frequency in air by a factor of three, which was also verified in the experiment. These simulation and experimental studies demonstrate how much "dynamic force," in terms of a membrane's maximum displacement, maximum force and driving frequency, can be produced by an actuator membrane interacting with fluid.
NASA Astrophysics Data System (ADS)
Karabat, Cagatay; Kiraz, Mehmet Sabir; Erdogan, Hakan; Savas, Erkay
2015-12-01
In this paper, we introduce a new biometric verification and template protection system which we call THRIVE. The system includes novel enrollment and authentication protocols based on threshold homomorphic encryption where a private key is shared between a user and a verifier. In the THRIVE system, only encrypted binary biometric templates are stored in a database and verification is performed via homomorphically randomized templates, thus, original templates are never revealed during authentication. Due to the underlying threshold homomorphic encryption scheme, a malicious database owner cannot perform full decryption on encrypted templates of the users in the database. In addition, security of the THRIVE system is enhanced using a two-factor authentication scheme involving user's private key and biometric data. Using simulation-based techniques, the proposed system is proven secure in the malicious model. The proposed system is suitable for applications where the user does not want to reveal her biometrics to the verifier in plain form, but needs to prove her identity by using biometrics. The system can be used with any biometric modality where a feature extraction method yields a fixed size binary template and a query template is verified when its Hamming distance to the database template is less than a threshold. The overall connection time for the proposed THRIVE system is estimated to be 336 ms on average for 256-bit biometric templates on a desktop PC running with quad core 3.2 GHz CPUs at 10 Mbit/s up/down link connection speed. Consequently, the proposed system can be efficiently used in real-life applications.
Formally verifying human–automation interaction as part of a system model: limitations and tradeoffs
Bass, Ellen J.
2011-01-01
Both the human factors engineering (HFE) and formal methods communities are concerned with improving the design of safety-critical systems. This work discusses a modeling effort that leveraged methods from both fields to perform formal verification of human–automation interaction with a programmable device. This effort utilizes a system architecture composed of independent models of the human mission, human task behavior, human-device interface, device automation, and operational environment. The goals of this architecture were to allow HFE practitioners to perform formal verifications of realistic systems that depend on human–automation interaction in a reasonable amount of time using representative models, intuitive modeling constructs, and decoupled models of system components that could be easily changed to support multiple analyses. This framework was instantiated using a patient controlled analgesia pump in a two phased process where models in each phase were verified using a common set of specifications. The first phase focused on the mission, human-device interface, and device automation; and included a simple, unconstrained human task behavior model. The second phase replaced the unconstrained task model with one representing normative pump programming behavior. Because models produced in the first phase were too large for the model checker to verify, a number of model revisions were undertaken that affected the goals of the effort. While the use of human task behavior models in the second phase helped mitigate model complexity, verification time increased. Additional modeling tools and technological developments are necessary for model checking to become a more usable technique for HFE. PMID:21572930
MO-D-BRB-02: The Radiological Physics Center's Quality Audit Program: Where Can We Improve?
Followill, D; Lowenstein, J; Molineu, A; Alvarez, P; Aguirre, J; Kry, S; Summers, P; Ibbott, G
2012-06-01
To analyze the findings of the Radiological Physics Center's (RPC) QA audits of institutions participating in NCI sponsored clinical trials. The RPC has developed an extensive Quality Assurance (QA) program over the past 44 years. This program includes on-site dosimetry reviews where measurements on therapy machines are made, records are reviewed and personnel are interviewed. The program's remote audit tools include mailed dosimeters (OSLD/TLD) to verify output calibration, comparison of dosimetry data with RPC 'standard' data, evaluation of benchmark and patient calculations to verify the treatment planning algorithms, review of institution's QA procedures and records, and use of anthropomorphic phantoms to verify tumor dose delivery. The RPC endeavors to assist institutions in finding the origins of any detected discrepancies, and to resolve them. Ninety percent of institutions receiving dosimetry recommendations has remained level for the past 5 years. The most frequent recommendations were for not performing TG-40 QA tests, wedge factors, small field size output factors and off-axis factors. Since TG-51 was published, the number of beam calibrations audited during visits with ion chambers, that met the RPC's ±3% criterion, decreased initially but has risen to pre-TG-51 levels. The OSLD/TLD program shows that only ∼3% of the beams are outside our ±5% criteria, but these discrepancies are distributed over 12-20% of the institutions. The percent of institutions with ï, 3 l beam outside the RPC's criteria is approximately the same whether OSLD/TLD or ion chambers were used. The first time passing rate for the anthropomorphic phantoms is increasing with time. The prostate phantom has the highest pass rate while the spine phantom has the lowest. Numerous dosimetry errors continue to be discovered by the RPC's QA program and the RPC continues to play an important role in helping institutions resolve these errors. This work was supported by PHS grants CA10953 and CA081647 awarded by NCI. © 2012 American Association of Physicists in Medicine.
NASA Technical Reports Server (NTRS)
Tegart, J. R.; Aydelott, J. C.
1978-01-01
The design of surface tension propellant acquisition systems using fine-mesh screen must take into account all factors that influence the liquid pressure differentials within the system. One of those factors is spacecraft vibration. Analytical models to predict the effects of vibration have been developed. A test program to verify the analytical models and to allow a comparative evaluation of the parameters influencing the response to vibration was performed. Screen specimens were tested under conditions simulating the operation of an acquisition system, considering the effects of such parameters as screen orientation and configuration, screen support method, screen mesh, liquid flow and liquid properties. An analytical model, based on empirical coefficients, was most successful in predicting the effects of vibration.
Balduck, A-L; Jowett, S
2010-10-01
The study examined the psychometric properties of the Belgian coach version of the Coach-Athlete Relationship Questionnaire (CART-Q). The questionnaire includes three dimensions (Closeness, Commitment, and Complementarity) in a model that intends to measure the quality of the coach-athlete relationship. Belgian coaches (n=144) of athletes who performed at various competition levels in such sports as football, basketball, and volleyball responded to the CART-Q and to the Leadership Scale for Sport (LSS). A confirmatory factor analysis proved to be slightly more satisfactory for a three-order factor model, compared with a hierarchical first-order factor model. The three factors showed acceptable internal consistency scores. Moreover, functional associations between the three factors and coach leadership behaviors were found offering support to the instrument's concurrent validity. The findings support previous validation studies and verify the psychometric properties of the CART-Q applied to Belgian coaches of team sports. © 2009 John Wiley & Sons A/S.
The effect of pressure on spontaneous Rayleigh-Brillouin scattering spectrum in nitrogen
NASA Astrophysics Data System (ADS)
Yang, Chuanyin; Wu, Tao; Shang, Jingcheng; Zhang, Xinyi; Hu, Rongjing; He, XingDao
2018-05-01
In order to study the effect of gas pressure on spontaneous Rayleigh-Brillouin scattering spectrum and verify the validity of Tenti S6 model at pressures up to 8 atm, the spontaneous Rayleigh-Brillouin scattering experiment in nitrogen was performed for a wavelength of 532 nm at the constant room temperature of 296 K and a 90° scattering angle. By comparing the experimental spectrum with the theoretical spectrum, the normalized root mean square deviation was calculated and found less than 2.2%. It is verified that Tenti S6 model can be applied to the spontaneous Rayleigh-Brillion scattering of nitrogen under higher pressures. The results of the experimental data analysis demonstrate that pressure has more effect on Brillouin peak intensity and has negligible effect on Brillouin frequency shift, and pressure retrieval based on spontaneous Rayleigh-Brillouin scattering profile is a promising method for remote of pressure, such as harsh environment applications. Some factors that caused experiment deviations are also discussed.
The Effect of Selenium Enrichment on Baker s Yeast Proteome
El-Bayoumy, Karam; Das, Arunangshu; Russell, Stephen; Wolfe, Steven; Jordan, Rick; Renganathan, Kutralanathan; Loughran, Thomas P.; Somiari, Richard
2011-01-01
The use of regular yeast (RY) and selenium-enriched yeast (SEY) as dietary supplement is of interest because the Nutritional Prevention of Cancer (NPC) trial revealed that SEY but not RY decreased the incidence of prostate cancer (PC). Using two-dimensional difference in gel electrophoresis (2D-DIGE) – tandem mass spectrometry (MS/MS) approach, we performed proteomic analysis of RY and SEY to identify proteins that are differentially expressed as a result of selenium enrichment. 2D-DIGE revealed 96 candidate protein spots that were differentially expressed (p≤0.05) between SEY and RY. The 96 spots were selected, sequenced by LC/MS/MS and 37 proteins were unequivocally identified. The 37 identified proteins were verified with ProteinProphet software and mapped to existing Gene Ontology categories. Furthermore, the expression profile of 5 of the proteins with validated or putative roles in the carcinogenesis process, and for which antibodies against human forms of the proteins are available commercially were verified by western analysis. This study provides evidence for the first time that SEY contains higher levels of Pyruvate Kinase, HSP70, and Elongation factor 2 and lower levels of Eukaryotic Translation Initiation Factor 5A-2 and Triosephosphate Isomerase than those found in RY. PMID:22067702
Association between obesity-related biomarkers and cognitive and motor development in infants.
Camargos, Ana Cristina R; Mendonça, Vanessa A; Oliveira, Katherine S C; de Andrade, Camila Alves; Leite, Hércules Ribeiro; da Fonseca, Sueli Ferreira; Vieira, Erica Leandro Marciano; Teixeira Júnior, Antônio Lúcio; Lacerda, Ana Cristina Rodrigues
2017-05-15
This study aimed to verify the association between obesity-related biomarkers and cognitive and motor development in infants between 6 and 24 months of age. A cross-sectional study was conducted with 50 infants and plasma levels of leptin, adiponectin, resistin, soluble tumor necrosis factor receptors 1 and 2 (sTNFR1 and sTNFR2), chemokines, brain-derived neurotrophic factor (BDNF), serum cortisol and redox status were measured. The Bayley-III test was utilized to evaluate cognitive and motor development, and multiple linear stepwise regression models were performed to verify the association between selected biomarkers and cognitive and motor development. A significant association was found among plasma leptin and sTNFR1 levels with cognitive composite scores, and these two independents variables together explained 37% of the variability of cognitive composite scores (p=0.001). Only plasma sTNFR1 levels were associated and explained 24% of the variability of motor composite scores (p=0.003). Plasma levels of sTNFR1 were associated with the increase in cognitive and motor development scores in infants between 6 and 24 months of age through a mechanism not directly related to excess body weight. Moreover, increase in plasma levels of leptin reduced the cognitive development in this age range. Copyright © 2017 Elsevier B.V. All rights reserved.
Confirmatory factor analysis applied to the Force Concept Inventory
NASA Astrophysics Data System (ADS)
Eaton, Philip; Willoughby, Shannon D.
2018-06-01
In 1995, Huffman and Heller used exploratory factor analysis to draw into question the factors of the Force Concept Inventory (FCI). Since then several papers have been published examining the factors of the FCI on larger sets of student responses and understandable factors were extracted as a result. However, none of these proposed factor models have been verified to not be unique to their original sample through the use of independent sets of data. This paper seeks to confirm the factor models proposed by Scott et al. in 2012, and Hestenes et al. in 1992, as well as another expert model proposed within this study through the use of confirmatory factor analysis (CFA) and a sample of 20 822 postinstruction student responses to the FCI. Upon application of CFA using the full sample, all three models were found to fit the data with acceptable global fit statistics. However, when CFA was performed using these models on smaller sample sizes the models proposed by Scott et al. and Eaton and Willoughby were found to be far more stable than the model proposed by Hestenes et al. The goodness of fit of these models to the data suggests that the FCI can be scored on factors that are not unique to a single class. These scores could then be used to comment on how instruction methods effect the performance of students along a single factor and more in-depth analyses of curriculum changes may be possible as a result.
Adaptation and validation of the Inventory of Family Protective Factors for the Portuguese culture
Augusto, Cláudia Cristina Vieira Carvalho de Oliveira Ferreira; Araújo, Beatriz Rodrigues; Rodrigues, Vítor Manuel Costa Pereira; de Figueiredo, Maria do Céu Aguiar Barbieri
2014-01-01
OBJECTIVES: to adapt and validate the Inventory of Family Protective Factors (IFPF) for the Portuguese culture. This instrument assesses protective factors that contribute to family resilience. Studies addressing resilience are embedded within the salutogenic paradigm, i.e. it addresses protective factors of individuals or groups without underestimating risk factors or vulnerability. METHOD: in order to assess the IFPF's linguistic and conceptual equivalence, the instrument was translated, retro-translated and the think-aloud protocol was used. We then verified the instrument's sensitiveness, reliability and validity of results to assess its psychometric characteristics. A factor analysis was performed of the principal components with varimax rotation of the scale's items and Cronbach's alpha coefficient was calculated for each dimension. A total of 85 families with disabled children, selected through simple random sampling, self-administered the instrument. RESULTS: the IFPF presents psychometric characteristics that are appropriate for the Portuguese population (Cronbach's alpha = .90). CONCLUSION: the IFPF was adapted and validated for the Portuguese culture and is an instrument to be used in studies intended to assess protective factors of family resilience. PMID:25591096
Adaptation and validation of the Inventory of Family Protective Factors for the Portuguese culture.
Augusto, Cláudia Cristina Vieira Carvalho de Oliveira Ferreira; Araújo, Beatriz Rodrigues; Rodrigues, Vítor Manuel Costa Pereira; de Figueiredo, Maria do Céu Aguiar Barbieri
2014-01-01
to adapt and validate the Inventory of Family Protective Factors (IFPF) for the Portuguese culture. This instrument assesses protective factors that contribute to family resilience. Studies addressing resilience are embedded within the salutogenic paradigm, i.e. it addresses protective factors of individuals or groups without underestimating risk factors or vulnerability. in order to assess the IFPF's linguistic and conceptual equivalence, the instrument was translated, retro-translated and the think-aloud protocol was used. We then verified the instrument's sensitiveness, reliability and validity of results to assess its psychometric characteristics. A factor analysis was performed of the principal components with varimax rotation of the scale's items and Cronbach's alpha coefficient was calculated for each dimension. A total of 85 families with disabled children, selected through simple random sampling, self-administered the instrument. the IFPF presents psychometric characteristics that are appropriate for the Portuguese population (Cronbach's alpha = .90). the IFPF was adapted and validated for the Portuguese culture and is an instrument to be used in studies intended to assess protective factors of family resilience.
Postures and Motions Library Development for Verification of Ground Crew Human Factors Requirements
NASA Technical Reports Server (NTRS)
Stambolian, Damon; Henderson, Gena; Jackson, Mariea Dunn; Dischinger, Charles
2013-01-01
Spacecraft and launch vehicle ground processing activities require a variety of unique human activities. These activities are being documented in a primitive motion capture library. The library will be used by human factors engineering analysts to infuse real to life human activities into the CAD models to verify ground systems human factors requirements. As the primitive models are being developed for the library, the project has selected several current human factors issues to be addressed for the Space Launch System (SLS) and Orion launch systems. This paper explains how the motion capture of unique ground systems activities is being used to verify the human factors engineering requirements for ground systems used to process the SLS and Orion vehicles, and how the primitive models will be applied to future spacecraft and launch vehicle processing.
High Performance Flat Plate Solar Thermal Collector Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rockenbaugh, Caleb; Dean, Jesse; Lovullo, David
2016-09-01
This report was prepared for the General Services Administration by the National Renewable Energy Laboratory. The Honeycomb Solar Thermal Collector (HSTC) is a flat plate solar thermal collector that shows promising high efficiencies over a wide range of climate zones. The technical objectives of this study are to: 1) verify collector performance, 2) compare that performance to other market-available collectors, 3) verify overheat protection, and 4) analyze the economic performance of the HSTC both at the demonstration sites and across a matrix of climate zones and utility markets.
NASA Astrophysics Data System (ADS)
Asghari, E.; Ashassi-Sorkhabi, H.; Ahangari, M.; Bagheri, R.
2016-04-01
Factors such as inhibitor concentration, solution hydrodynamics, and temperature influence the performance of corrosion inhibitor mixtures. The simultaneous studying of the impact of different factors is a time- and cost-consuming process. The use of experimental design methods can be useful in minimizing the number of experiments and finding local optimized conditions for factors under the investigation. In the present work, the inhibition performance of a three-component inhibitor mixture against corrosion of St37 steel rotating disk electrode, RDE, was studied. The mixture was composed of citric acid, lanthanum(III) nitrate, and tetrabutylammonium perchlorate. In order to decrease the number of experiments, the L16 Taguchi orthogonal array was used. The "control factors" were the concentration of each component and the rotation rate of RDE and the "response factor" was the inhibition efficiency. The scanning electron microscopy and energy dispersive x-ray spectroscopy techniques verified the formation of islands of adsorbed citrate complexes with lanthanum ions and insoluble lanthanum(III) hydroxide. From the Taguchi analysis results the mixture of 0.50 mM lanthanum(III) nitrate, 0.50 mM citric acid, and 2.0 mM tetrabutylammonium perchlorate under the electrode rotation rate of 1000 rpm was found as optimum conditions.
Sherer, Mark; Sander, Angelle M; Maestas, Kacey Little; Pastorek, Nicholas J; Nick, Todd G; Li, Jingyun
2015-04-01
To determine the accuracy of self-reported length of coma and posttraumatic amnesia (PTA) in persons with medically verified traumatic brain injury (TBI) and to investigate factors that affect self-report of length of coma and PTA duration. Prospective cohort study. Specialized rehabilitation center with inpatient and outpatient programs. Persons (N=242) with medically verified TBI who were identified from a registry of persons who had previously participated in TBI-related research. Not applicable. Self-reported length of coma and self-reported PTA duration. Review of medical records revealed that the mean medically documented length of coma and PTA duration was 6.9±12 and 19.2±22 days, respectively, and the mean self-reported length of coma and PTA duration was 16.7±22 and 106±194 days, respectively. The average discrepancy between self-report and medical record for length of coma and PTA duration was 8.2±21 and 64±176 days, respectively. Multivariable regression models revealed that time since injury, performance on cognitive tests, and medical record values were associated with self-reported values for both length of coma and PTA duration. In this investigation, persons with medically verified TBI showed poor accuracy in their self-report of length of coma and PTA duration. Discrepancies were large enough to affect injury severity classification. Caution should be exercised when considering self-report of length of coma and PTA duration. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Analysis of sound absorption performance of an electroacoustic absorber using a vented enclosure
NASA Astrophysics Data System (ADS)
Cho, Youngeun; Wang, Semyung; Hyun, Jaeyub; Oh, Seungjae; Goo, Seongyeol
2018-03-01
The sound absorption performance of an electroacoustic absorber (EA) is primarily influenced by the dynamic characteristics of the loudspeaker that acts as the actuator of the EA system. Therefore, the sound absorption performance of the EA is maximum at the resonance frequency of the loudspeaker and tends to degrade in the low-frequency and high-frequency bands based on this resonance frequency. In this study, to adjust the sound absorption performance of the EA system in the low-frequency band of approximately 20-80 Hz, an EA system using a vented enclosure that has previously been used to enhance the radiating sound pressure of a loudspeaker in the low-frequency band, is proposed. To verify the usefulness of the proposed system, two acoustic environments are considered. In the first acoustic environment, the vent of the vented enclosure is connected to an external sound field that is distinct from the sound field coupled to the EA. In this case, the acoustic effect of the vented enclosure on the performance of the EA is analyzed through an analytical approach using dynamic equations and an impedance-based equivalent circuit. Then, it is verified through numerical and experimental approaches. Next, in the second acoustic environment, the vent is connected to the same external sound field as the EA. In this case, the effect of the vented enclosure on the EA is investigated through an analytical approach and finally verified through a numerical approach. As a result, it is confirmed that the characteristics of the sound absorption performances of the proposed EA system using the vented enclosure in the two acoustic environments considered in this study are different from each other in the low-frequency band of approximately 20-80 Hz. Furthermore, several case studies on the change tendency of the performance of the EA using the vented enclosure according to the critical design factors or vent number for the vented enclosure are also investigated. In the future, even if the proposed EA system using a vented enclosure is extended to a large number of arrays required for 3D sound field control, it is expected to be an attractive solution that can contribute to an improvement in low-frequency noise reduction without causing economic and system complexity problems.
The space shuttle launch vehicle aerodynamic verification challenges
NASA Technical Reports Server (NTRS)
Wallace, R. O.; Austin, L. D.; Hondros, J. G.; Surber, T. E.; Gaines, L. M.; Hamilton, J. T.
1985-01-01
The Space Shuttle aerodynamics and performance communities were challenged to verify the Space Shuttle vehicle (SSV) aerodynamics and system performance by flight measurements. Historically, launch vehicle flight test programs which faced these same challenges were unmanned instrumented flights of simple aerodynamically shaped vehicles. However, the manned SSV flight test program made these challenges more complex because of the unique aerodynamic configuration powered by the first man-rated solid rocket boosters (SRB). The analyses of flight data did not verify the aerodynamics or performance preflight predictions of the first flight of the Space Transportation System (STS-1). However, these analyses have defined the SSV aerodynamics and verified system performance. The aerodynamics community also was challenged to understand the discrepancy between the wind tunnel and flight defined aerodynamics. The preflight analysis challenges, the aerodynamic extraction challenges, and the postflight analyses challenges which led to the SSV system performance verification and which will lead to the verification of the operational ascent aerodynamics data base are presented.
Ben Abid, Sadreddine; Mzoughi, Zeineb; Attaoui, Mohamed Amine; Talbi, Ghofrane; Arfa, Nafaa; Gharbi, Lassaad; Khalfallah, Mohamed Taher
2014-12-01
feasibility and advantages of laparoscopic approach in performed duodenal ulcer have no longer to be demonstrated. Laparoscopic suture and peritoneal cleaning expose to a conversion rate between 10 and 23%. However less than laparotomy, morbidity of this approach is not absent. This study aim to analyze factors exposing to conversion after laparoscopic approach of perforred duodenal ulcer. We also aim to define the morbidity of this approach and predictive factors of this morbidity Methods: Retrospective descriptive study was conducted referring all cases of perforated duodenal ulcer treated laparoscopically over a period of ten years, running from January 2000 to December 2010. All patients were operated by laparoscopy with or without conversion. We have noted conversion factors. A statistical analysis with logistic regression was performed whenever we have sought to identify independent risk factors for conversion verified as statistically significant in univariante. The significance level was set at 5%. Analytic univariant and multivariant study was performed to analyze morbidity factors. 290 patients were included. The median age was 34ans.T he intervention was conducted completely laparoscopically in 91.4% of cases. The conversion rate was 8.6%. It was selected as a risk factor for conversion: age> 32 years, a known ulcer, progressive pain, renal function failure, a difficult peritoneal lavage and having a chronic ulcer. Postoperative morbidity was 5.1%. Three independent risk factors of surgical complications were selected: renal failure, age> 45 years, and a chronic ulcer appearance. Laparoscopic treatment of perforred duodenal ulcer expose to a conversion risk. Morbidity is certainly less than laparotomy and a better Knowledge of predictif's morbidity factors become necessary for a better management of this disease.
Zhang, Tao; Ding, Yuanyuan; An, Hongli; Feng, Liuxin; Wang, Sicen
2015-07-14
Tyrosine 367 Cysteine-fibroblast growth factor receptor 4 cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry was developed. Tyrosine 367 Cysteine-HEK293 cells were used as cell membrane stationary phase. Specificity and reproducibility of the cell membrane chromatography was evaluated using 1-tert-butyl-3-{2-[4-(diethylamino)butylamino]-6-(3,5-dimethoxyphenyl)pyrido[2,3-d]pyrimidin-7-yl}urea, Nimodipine and dexamethasone acetate. Then, anti-tumor components acting on Tyrosine 367 Cysteine-fibroblast growth factor receptor 4 were screened and identified from extracts of Ligusticum wallichii. Components from the extract were retained on the cell membrane chromatographic column. The retained fraction was directly eluted into high-performance liquid chromatography with mass spectrometry system for separation and identification. Finally, Levistolide A was identified as an active component from Ligusticum wallichii extracts. The 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-tetrazolium bromide-formazan colorimetric assay revealed that Levistolide A inhibits proliferation of overexpressing the mutated receptor cells with dose-dependent manner. Phosphorylation of fibroblast growth factor receptor 4 was also decrease under Levistolide A treatment. Flex dock simulation verified that Levistolide A could bind with the tyrosine kinase domain of fibroblast growth factor receptor 4. Therefore, Levistolide A screened by the cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry can arrest cell growth. In conclusion, the two-dimensional high-performance liquid chromatography method can screen and identify potential anti-tumor ingredients which specifically act on the tyrosine kinase domain of the mutated fibroblast growth factor receptor 4. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
A Study of Wind Turbine Comprehensive Operational Assessment Model Based on EM-PCA Algorithm
NASA Astrophysics Data System (ADS)
Zhou, Minqiang; Xu, Bin; Zhan, Yangyan; Ren, Danyuan; Liu, Dexing
2018-01-01
To assess wind turbine performance accurately and provide theoretical basis for wind farm management, a hybrid assessment model based on Entropy Method and Principle Component Analysis (EM-PCA) was established, which took most factors of operational performance into consideration and reach to a comprehensive result. To verify the model, six wind turbines were chosen as the research objects, the ranking obtained by the method proposed in the paper were 4#>6#>1#>5#>2#>3#, which are completely in conformity with the theoretical ranking, which indicates that the reliability and effectiveness of the EM-PCA method are high. The method could give guidance for processing unit state comparison among different units and launching wind farm operational assessment.
Optimal design application on the advanced aeroelastic rotor blade
NASA Technical Reports Server (NTRS)
Wei, F. S.; Jones, R.
1985-01-01
The vibration and performance optimization procedure using regression analysis was successfully applied to an advanced aeroelastic blade design study. The major advantage of this regression technique is that multiple optimizations can be performed to evaluate the effects of various objective functions and constraint functions. The data bases obtained from the rotorcraft flight simulation program C81 and Myklestad mode shape program are analytically determined as a function of each design variable. This approach has been verified for various blade radial ballast weight locations and blade planforms. This method can also be utilized to ascertain the effect of a particular cost function which is composed of several objective functions with different weighting factors for various mission requirements without any additional effort.
High-frequency AC/DC converter with unity power factor and minimum harmonic distortion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wernekinch, E.R.
1987-01-01
The power factor is controlled by adjusting the relative position of the fundamental component of an optimized PWM-type voltage with respect to the supply voltage. Current harmonic distortion is minimized by the use of optimized firing angles for the converter at a frequency where GTO's can be used. This feature makes this approach very attractive at power levels of 100 to 600 kW. To obtain the optimized PWM pattern, a steepest descent digital computer algorithm is used. Digital-computer simulations are performed and a low-power model is constructed and tested to verify the concepts and the behavior of the model. Experimentalmore » results show that unity power factor is achieved and that the distortion in the phase currents is 10.4% at 90% of full load. This is less than achievable with sinusoidal PWM, harmonic elimination, hysteresis control, and deadbeat control for the same switching frequency.« less
Lee, Myeongjun; Kim, Hyunjung; Shin, Donghee; Lee, Sangyun
2016-01-01
Harassment means systemic and repeated unethical acts. Research on workplace harassment have been conducted widely and the NAQ-R has been widely used for the researches. But this tool, however the limitations in revealing differended in sub-factors depending on the culture and in reflecting that unique characteristics of the Koren society. So, The workplace harassment questionnaire for Korean finace and service workers has been developed to assess the level of personal harassment at work. This study aims to develop a tool to assess the level of personal harassment at work and to test its validity and reliability while examining specific characteristics of workplace harassment against finance and service workers in Korea. The framework of survey was established based on literature review, focused-group interview for the Korean finance and service workers. To verify its reliability, Cronbach's alpha coefficient was calculated; and to verify its validity, items and factors of the tool were analyzed. The correlation matrix analysis was examined to verify the tool's convergent validity and discriminant validity. Structural validity was verified by checking statistical significance in relation to the BDI-K. Cronbach's alpha coefficient of this survey was 0.93, which indicates a quite high level of reliability. To verify the appropriateness of this survey tool, its construct validity was examined through factor analysis. As a result of the factor analysis, 3 factors were extracted, explaining 56.5 % of the total variance. The loading values and communalities of the 20 items were 0.85 to 0.48 and 0.71 to 0.46. The convergent validity and discriminant validity were analyzed and rate of item discriminant validity was 100 %. Finally, for the concurrent validity, We examined the relationship between the WHI-KFSW and pschosocial stress by examining the correlation with the BDI-K. The results of chi-square test and multiple logistic analysis indicated that the correlation with the BDI-K was satatisctically significant. Workplace harassment in actual workplaces were investigated based on interviews, and the statistical analysis contributed to systematizing the types of actual workplace harassment. By statistical method, we developed the questionare, 20 items of 3 categories.
Aerodynamic characteristics and heat radiation performance of sportswear fabrics
NASA Astrophysics Data System (ADS)
Koga, H.; Hiratsuka, M.; Ito, S.; Konno, A.
2017-10-01
Sports such as swimming, speed skating, and marathon are sports competing for time. In recent years, reduction of the fluid drag of sportswear is required for these competitions in order to improve the record. In addition, sweating and discomfort due to body temperature rise during competition are thought to affect competitor performance, and heat radiation performance is also an important factor for sportswear. The authors have measured fluid force drag by wrapping cloth around a cylinder and have confirmed their differences due to the roughness of the fabric surface, differences in sewing. The authors could be verified the drag can be reduced by the position of the wear stitch. This time, we measured the heat radiation performance of 14 types of cloths whose aero dynamic properties are known using cylinders which are regarded as human fuselages, and found elements of cloth with heat radiation performance. It was found to be important for raising the heat radiation performance of sportswear that the fabric is thin and flat surface processing.
[Detection of factor VIII intron 1 inversion in severe haemophilia A].
Liang, Yan; Yan, Zhen-yu; Yan, Mei; Hua, Bao-lai; Xiao, Bai; Zhao, Yong-qiang; Liu, Jing-zhong
2009-06-01
Screening the intron 1 inversion of factor VIII (FVIII) in the population of severe haemophilia A(HA) in China and performing carrier detection and prenatal diagnosis. Using LD-PCR to detect intron 22 inversions and multiple-PCR within two tubes to intron 1 inversions in severe HA patients. Carrier detection and prenatal diagnosis were performed in affected families. Linkage analysis and DNA sequencing were used to verify these tests. One hundred and eighteen patients were seven diagnosed as intron 22 inversions and 7 were intron 1 inversions out of 247 severe HA patients. The prevalence of the intron 1 inversion in Chinese severe haemophilia A patients was 2.8% (7/247). Six women from family A and 2 from family B were diagnosed as carriers. One fetus from family A was affected fetus. Intron 1 inversion could be detected directly by multiple-PCR within two tubes. This method made the strategy more perfective in carrier and prenatal diagnosis of haemophilia A.
NASA Technical Reports Server (NTRS)
Junge, M. K.; Giacomi, M. J.
1981-01-01
The results of a human factors test to assay the suitability of a prototype general purpose work station (GPWS) for biosciences experiments on the fourth Spacelab mission are reported. The evaluation was performed to verify that users of the GPWS would optimally interact with the GPWS configuration and instrumentation. Six male subjects sat on stools positioned to allow assimilation of the zero-g body posture. Trials were run concerning the operator viewing angles facing the console, the console color, procedures for injecting rates with dye, a rat blood cell count, mouse dissection, squirrel monkey transfer, and plant fixation. The trials were run for several days in order to gage improvement or poor performance conditions. Better access to the work surface was found necessary, together with more distinct and better located LEDs, better access window latches, clearer sequences on control buttons, color-coded sequential buttons, and provisions made for an intercom system when operators of the GPWS work in tandem.
Surface laser marking optimization using an experimental design approach
NASA Astrophysics Data System (ADS)
Brihmat-Hamadi, F.; Amara, E. H.; Lavisse, L.; Jouvard, J. M.; Cicala, E.; Kellou, H.
2017-04-01
Laser surface marking is performed on a titanium substrate using a pulsed frequency doubled Nd:YAG laser ( λ= 532 nm, τ pulse=5 ns) to process the substrate surface under normal atmospheric conditions. The aim of the work is to investigate, following experimental and statistical approaches, the correlation between the process parameters and the response variables (output), using a Design of Experiment method (DOE): Taguchi methodology and a response surface methodology (RSM). A design is first created using MINTAB program, and then the laser marking process is performed according to the planned design. The response variables; surface roughness and surface reflectance were measured for each sample, and incorporated into the design matrix. The results are then analyzed and the RSM model is developed and verified for predicting the process output for the given set of process parameters values. The analysis shows that the laser beam scanning speed is the most influential operating factor followed by the laser pumping intensity during marking, while the other factors show complex influences on the objective functions.
GRMDA: Graph Regression for MiRNA-Disease Association Prediction
Chen, Xing; Yang, Jing-Ru; Guan, Na-Na; Li, Jian-Qiang
2018-01-01
Nowadays, as more and more associations between microRNAs (miRNAs) and diseases have been discovered, miRNA has gradually become a hot topic in the biological field. Because of the high consumption of time and money on carrying out biological experiments, computational method which can help scientists choose the most likely associations between miRNAs and diseases for further experimental studies is desperately needed. In this study, we proposed a method of Graph Regression for MiRNA-Disease Association prediction (GRMDA) which combines known miRNA-disease associations, miRNA functional similarity, disease semantic similarity, and Gaussian interaction profile kernel similarity. We used Gaussian interaction profile kernel similarity to supplement the shortage of miRNA functional similarity and disease semantic similarity. Furthermore, the graph regression was synchronously performed in three latent spaces, including association space, miRNA similarity space, and disease similarity space, by using two matrix factorization approaches called Singular Value Decomposition and Partial Least-Squares to extract important related attributes and filter the noise. In the leave-one-out cross validation and five-fold cross validation, GRMDA obtained the AUCs of 0.8272 and 0.8080 ± 0.0024, respectively. Thus, its performance is better than some previous models. In the case study of Lymphoma using the recorded miRNA-disease associations in HMDD V2.0 database, 88% of top 50 predicted miRNAs were verified by experimental literatures. In order to test the performance of GRMDA on new diseases with no known related miRNAs, we took Breast Neoplasms as an example by regarding all the known related miRNAs as unknown ones. We found that 100% of top 50 predicted miRNAs were verified. Moreover, 84% of top 50 predicted miRNAs in case study for Esophageal Neoplasms based on HMDD V1.0 were verified to have known associations. In conclusion, GRMDA is an effective and practical method for miRNA-disease association prediction. PMID:29515453
GRMDA: Graph Regression for MiRNA-Disease Association Prediction.
Chen, Xing; Yang, Jing-Ru; Guan, Na-Na; Li, Jian-Qiang
2018-01-01
Nowadays, as more and more associations between microRNAs (miRNAs) and diseases have been discovered, miRNA has gradually become a hot topic in the biological field. Because of the high consumption of time and money on carrying out biological experiments, computational method which can help scientists choose the most likely associations between miRNAs and diseases for further experimental studies is desperately needed. In this study, we proposed a method of Graph Regression for MiRNA-Disease Association prediction (GRMDA) which combines known miRNA-disease associations, miRNA functional similarity, disease semantic similarity, and Gaussian interaction profile kernel similarity. We used Gaussian interaction profile kernel similarity to supplement the shortage of miRNA functional similarity and disease semantic similarity. Furthermore, the graph regression was synchronously performed in three latent spaces, including association space, miRNA similarity space, and disease similarity space, by using two matrix factorization approaches called Singular Value Decomposition and Partial Least-Squares to extract important related attributes and filter the noise. In the leave-one-out cross validation and five-fold cross validation, GRMDA obtained the AUCs of 0.8272 and 0.8080 ± 0.0024, respectively. Thus, its performance is better than some previous models. In the case study of Lymphoma using the recorded miRNA-disease associations in HMDD V2.0 database, 88% of top 50 predicted miRNAs were verified by experimental literatures. In order to test the performance of GRMDA on new diseases with no known related miRNAs, we took Breast Neoplasms as an example by regarding all the known related miRNAs as unknown ones. We found that 100% of top 50 predicted miRNAs were verified. Moreover, 84% of top 50 predicted miRNAs in case study for Esophageal Neoplasms based on HMDD V1.0 were verified to have known associations. In conclusion, GRMDA is an effective and practical method for miRNA-disease association prediction.
Investigation, Development, and Evaluation of Performance Proving for Fault-tolerant Computers
NASA Technical Reports Server (NTRS)
Levitt, K. N.; Schwartz, R.; Hare, D.; Moore, J. S.; Melliar-Smith, P. M.; Shostak, R. E.; Boyer, R. S.; Green, M. W.; Elliott, W. D.
1983-01-01
A number of methodologies for verifying systems and computer based tools that assist users in verifying their systems were developed. These tools were applied to verify in part the SIFT ultrareliable aircraft computer. Topics covered included: STP theorem prover; design verification of SIFT; high level language code verification; assembly language level verification; numerical algorithm verification; verification of flight control programs; and verification of hardware logic.
Fast Decentralized Averaging via Multi-scale Gossip
NASA Astrophysics Data System (ADS)
Tsianos, Konstantinos I.; Rabbat, Michael G.
We are interested in the problem of computing the average consensus in a distributed fashion on random geometric graphs. We describe a new algorithm called Multi-scale Gossip which employs a hierarchical decomposition of the graph to partition the computation into tractable sub-problems. Using only pairwise messages of fixed size that travel at most O(n^{1/3}) hops, our algorithm is robust and has communication cost of O(n loglogn logɛ - 1) transmissions, which is order-optimal up to the logarithmic factor in n. Simulated experiments verify the good expected performance on graphs of many thousands of nodes.
Qiu, Cheng-Wei; Hu, Li; Zhang, Baile; Wu, Bae-Ian; Johnson, Steven G; Joannopoulos, John D
2009-08-03
Two novel classes of spherical invisibility cloaks based on nonlinear transformation have been studied. The cloaking characteristics are presented by segmenting the nonlinear transformation based spherical cloak into concentric isotropic homogeneous coatings. Detailed investigations of the optimal discretization (e.g., thickness control of each layer, nonlinear factor, etc.) are presented for both linear and nonlinear spherical cloaks and their effects on invisibility performance are also discussed. The cloaking properties and our choice of optimal segmentation are verified by the numerical simulation of not only near-field electric-field distribution but also the far-field radar cross section (RCS).
NASA Astrophysics Data System (ADS)
Jindal, Sumit Kumar; Mahajan, Ankush; Raghuwanshi, Sanjeev Kumar
2017-10-01
An analytical model and numerical simulation for the performance of MEMS capacitive pressure sensors in both normal and touch modes is required for expected behavior of the sensor prior to their fabrication. Obtaining such information should be based on a complete analysis of performance parameters such as deflection of diaphragm, change of capacitance when the diaphragm deflects, and sensitivity of the sensor. In the literature, limited work has been carried out on the above-stated issue; moreover, due to approximation factors of polynomials, a tolerance error cannot be overseen. Reliable before-fabrication forecasting requires exact mathematical calculation of the parameters involved. A second-order polynomial equation is calculated mathematically for key performance parameters of both modes. This eliminates the approximation factor, and an exact result can be studied, maintaining high accuracy. The elimination of approximation factors and an approach of exact results are based on a new design parameter (δ) that we propose. The design parameter gives an initial hint to the designers on how the sensor will behave once it is fabricated. The complete work is aided by extensive mathematical detailing of all the parameters involved. Next, we verified our claims using MATLAB® simulation. Since MATLAB® effectively provides the simulation theory for the design approach, more complicated finite element method is not used.
NASA Astrophysics Data System (ADS)
Azadeh, A.; Salehi, V.; Salehi, R.
2017-10-01
Information systems (IS) are strongly influenced by changes in new technology and should react swiftly in response to external conditions. Resilience engineering is a new method that can enable these systems to absorb changes. In this study, a new framework is presented for performance evaluation of IS that includes DeLone and McLean's factors of success in addition to resilience. Hence, this study is an attempt to evaluate the impact of resilience on IS by the proposed model in Iranian Gas Engineering and Development Company via the data obtained from questionnaires and Fuzzy Data Envelopment Analysis (FDEA) approach. First, FDEA model with α-cut = 0.05 was identified as the most suitable model to this application by performing all Banker, Charnes and Cooper and Charnes, Cooper and Rhodes models of and FDEA and selecting the appropriate model based on maximum mean efficiency. Then, the factors were ranked based on the results of sensitivity analysis, which showed resilience had a significantly higher impact on the proposed model relative to other factors. The results of this study were then verified by conducting the related ANOVA test. This is the first study that examines the impact of resilience on IS by statistical and mathematical approaches.
Psychometric properties of Connor-Davidson Resilience Scale in a Spanish sample of entrepreneurs.
Manzano-García, Guadalupe; Ayala Calvo, Juan Carlos
2013-01-01
The literature regarding entrepreneurship suggests that the resilience of entrepreneurs may help to explain entrepreneurial success, but there is no resilience measure widely accepted by researchers. This study analyzes the psychometric properties of the Connor and Davidson Resilience Scale (CD-RISC) in a sample of Spanish entrepreneurs. A telephone survey research method was used. The participants were entrepreneurs operating in the business services sector. Interviewers telephoned a total of 900 entrepreneurs of whom 783 produced usable questionnaires. The CD-RISC was used as data collection instrument. We used principal component analysis factor and confirmatory factor analysis to determine the factor structure of the CD-RISC. Confirmatory factor analysis failed to verify the original five-factor structure of the CD-RISC, whereas principal component analysis factor yielded a 3-factor structure of resilience (hardiness, resourcefulness and optimism). In this research, 47.48% of the total variance was accounted for by three factors, and the obtained factor structure was verified through confirmatory factor analysis. The CD-RISC has been shown to be a reliable and valid tool for measuring entrepreneurs' resilience.
Lackner, Angelika; Duftner, Christina; Ficjan, Anja; Gretler, Judith; Hermann, Josef; Husic, Rusmir; Graninger, Winfried B; Dejaco, Christian
2016-10-01
To study the association of clinical and/or ultrasound variables with patients' (PGA) and physicians' (EGA) global assessment of disease activity in psoriatic arthritis (PsA). The correlation of these parameters with the discordance between PGA and EGA, as well as with PGA/EGA changes over 6 months was also investigated. Prospective study of 83 consecutive PsA patients with 2 visits scheduled 6 months apart. All patients underwent the following assessments: tender (TJC) and swollen joint count (SJC), PASI, dactylitis and Leeds enthesitis index. PGA, patients' level of pain (pain VAS), EGA, and HAQ were also recorded. Grey scale (GS) and power Doppler (PD) ultrasound were performed at 68 joints (evaluating synovia and tendons) and 14 entheses. Regression analyses were performed to assess the association of these variables with PGA and EGA. Two new variables "PGAminusEGA" and "PGAchange - EGAchange" were developed to explore the discrepancy between PGA and EGA and the consistency of PGA/EGA changes over time, respectively. The parameters explaining most of PGA and EGA variability were pain VAS (30.5%) and SJC (48.5%), respectively. The correlation between EGA and joint counts was stronger in patients with high vs. low levels of ultrasound verified inflammation. PGAminusEGA was mainly explained by pain and SJC. Pain was the most important predictor of PGA change whereas TJC and HAQ were more closely associated with EGA changes. "PGAchange-EGAchange" was linked to pain and SJC. Ultrasound scores were not linked with either of these variables. Pain VAS and joint counts are the most important clinical parameters explaining patients' and physicians' perception of disease activity, whereas the correlation of active inflammation as verified by sonography with these factors is limited. Copyright © 2016 Elsevier Inc. All rights reserved.
Zhang, Dongsheng; Wang, Shiyu; Xiu, Jie
2017-11-01
Elastic wave quality determines the operating performance of traveling wave ultrasonic motor (TWUM). The time-variant circumferential force from the shrink of piezoelectric ceramic is one of the factors that distort the elastic wave. The distorted waveshape deviates from the ideal standard sinusoidal fashion and affects the contact mechanics and driving performance. An analytical dynamic model of ring ultrasonic motor is developed. Based on this model, the piezoelectric parametric effects on the wave distortion and contact mechanics are examined. Multi-scale method is employed to obtain unstable regions and distorted wave response. The unstable region is verified by Floquét theory. Since the waveshape affects the contact mechanism, a contact model involving the distorted waveshape and normal stiffness of the contact layer is established. The contact model is solved by numerical calculation. The results verify that the deformation of the contact layer deviates from sinusoidal waveshape and the pressure distribution is changed, which influences the output characteristics directly. The surface speed within the contact region is averaged such that the rotor speed decreases for lower torque and increases for larger torque. The effects from different parametric strengths, excitation frequencies and pre-pressures on pressure distribution and torque-speed relation are compared. Copyright © 2017 Elsevier B.V. All rights reserved.
Flight motor set 360L008 (STS-32R). Volume 1: System overview
NASA Technical Reports Server (NTRS)
Garecht, D. M.
1990-01-01
Flight motor set 360L008 was launched as part of NASA space shuttle mission STS-32R. As with all previous redesigned solid rocket motor launches, overall motor performance was excellent. All ballistic contract end item specification parameters were verified with the exception of ignition interval and rise rates, which could not be verified due to elimination of developmental flight instrumentation. But the available low sample rate data showed nominal propulsion performance. All ballistic and mass property parameters closely matched the predicted values and were well within the required contract end item specification levels that could be assessed. All field joint heaters and igniter joint heaters performed without anomalies. Redesigned field joint heaters and the redesigned left-hand igniter heater were used on this flight. The changes to the heaters were primarily to improve durability and reducing handling damage. Evaluation of the ground environment instrumentation measurements again verified thermal mode analysis data and showed agreement with predicted environmental effects. No launch commit criteria violation occurred. Postflight inspection again verified superior performance of the insulation, phenolics, metal parts, and seals. Postflight evaluation indicated both nozzles performed as expected during flight. All combustion gas was contained by insulation in the field and case-to-nozzle joints. Recommendations were made concerning improved thermal modeling and measurements. The rationale for these recommendations and complete result details are presented.
The Effect of Smoking on the Risk of Sciatica: A Meta-analysis.
Shiri, Rahman; Falah-Hassani, Kobra
2016-01-01
The role of smoking in sciatica is unknown. This study aimed to estimate the effect of smoking on lumbar radicular pain and clinically verified sciatica. Comprehensive literature searches were conducted in PubMed, Embase, Web of Science, Scopus, Google Scholar, and ResearchGate databases from 1964 through March 2015. We used a random-effects meta-analysis, assessed heterogeneity and publication bias, and performed sensitivity analyses with regard to study design, methodological quality of included studies, and publication bias. Twenty-eight (7 cross-sectional [n = 20,111 participants], 8 case control [n = 10,815], and 13 cohort [n = 443,199]) studies qualified for a meta-analysis. Current smokers had an increased risk of lumbar radicular pain or clinically verified sciatica (pooled adjusted odds ratio [OR] 1.46; 95% confidence interval [CI], 1.30-1.64, n = 459,023). Former smokers had only slightly elevated risk compared with never smokers (pooled adjusted OR 1.15; 95% CI, 1.02-1.30, n = 387,196). For current smoking the pooled adjusted OR was 1.64 (95% CI, 1.24-2.16, n = 10,853) for lumbar radicular pain, 1.35 (95% CI, 1.09-1.68, n = 110,374) for clinically verified sciatica, and 1.45 (95% CI, 1.16-1.80, n = 337,796) for hospitalization or surgery due to a herniated lumbar disc or sciatica. The corresponding estimates for past smoking were 1.57 (95% CI, 0.98-2.52), 1.09 (95% CI, 1.00-1.19), and 1.10 (95% CI, 0.96-1.26). The associations did not differ between men and women, and they were independent of study design. Moreover, there was no evidence of publication bias, and the observed associations were not due to selection or detection bias, or confounding factors. Smoking is a modest risk factor for lumbar radicular pain and clinically verified sciatica. Smoking cessation appears to reduce, but not entirely eliminate, the excess risk. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Bolton, Matthew L.; Bass, Ellen J.
2009-01-01
Both the human factors engineering (HFE) and formal methods communities are concerned with finding and eliminating problems with safety-critical systems. This work discusses a modeling effort that leveraged methods from both fields to use model checking with HFE practices to perform formal verification of a human-interactive system. Despite the use of a seemingly simple target system, a patient controlled analgesia pump, the initial model proved to be difficult for the model checker to verify in a reasonable amount of time. This resulted in a number of model revisions that affected the HFE architectural, representativeness, and understandability goals of the effort. If formal methods are to meet the needs of the HFE community, additional modeling tools and technological developments are necessary.
Evolution of multiple quantum coherences with scaled dipolar Hamiltonian
NASA Astrophysics Data System (ADS)
Sánchez, Claudia M.; Buljubasich, Lisandro; Pastawski, Horacio M.; Chattah, Ana K.
2017-08-01
In this article, we introduce a pulse sequence which allows the monitoring of multiple quantum coherences distribution of correlated spin states developed with scaled dipolar Hamiltonian. The pulse sequence is a modification of our previous Proportionally Refocused Loschmidt echo (PRL echo) with phase increment, in order to verify the accuracy of the weighted coherent quantum dynamics. The experiments were carried out with different scaling factors to analyze the evolution of the total magnetization, the time dependence of the multiple quantum coherence orders, and the development of correlated spins clusters. In all cases, a strong dependence between the evolution rate and the weighting factor is observed. Remarkably, all the curves appeared overlapped in a single trend when plotted against the self-time, a new time scale that includes the scaling factor into the evolution time. In other words, the spin system displayed always the same quantum evolution, slowed down as the scaling factor decreases, confirming the high performance of the new pulse sequence.
Jeong, Bo Yoon; Lim, Min Kyung; Yun, E Hwa; Oh, Jin-Kyoung; Park, Eun Young; Lee, Do-Hoon
2014-10-01
We assessed the extent to which self-reported exposure to SHS underestimates the actual exposure to SHS and what factors are associated with a tolerance for SHS exposure in the Korean setting where the smoke-free policy is incomplete. Information on socio-demographic characteristics, alcohol drinking and smoking was collected for 7948 nonsmokers aged ≥ 19 years from the fourth Korea National Health and Nutrition Examination Survey, 2008-2009. Self-reported and cotinine verified SHS exposures were compared. Potential factors associated with cotinine verified but not self-reported SHS exposures were assessed using a logistic regression model. Self-reported SHS exposure significantly underestimated the actual SHS exposure as determined by cotinine verification (kappa coefficient: 0.1066). At younger age, frequent alcohol drinking in females and a longer smoking duration in males were positively associated with cotinine verified exposure but not with the self-reported SHS exposure; they were also positively associated with cotinine verified exposure irrespective of self-reported SHS exposure. Our findings show a tolerance for smoking in Korea. The current partial ban on smoking does not fully protect people from exposure to SHS. Smoking should be banned in all public places. In addition, efforts to de-normalize smoking in the Korean culture need to be strengthened. Copyright © 2014 Elsevier Inc. All rights reserved.
Periodically-Scheduled Controller Analysis using Hybrid Systems Reachability and Continuization
2015-12-01
tools to verify specifications for hybrid automata do not perform well on such periodically scheduled models. This is due to a combination of the large...an additive nondeterministic input. Reachability tools for hybrid automata can better handle such systems. We further improve the analysis by...formally as a hybrid automaton. However, reachability tools to verify specifications for hybrid automata do not perform well on such periodically
Analysis and prediction of Multiple-Site Damage (MSD) fatigue crack growth
NASA Technical Reports Server (NTRS)
Dawicke, D. S.; Newman, J. C., Jr.
1992-01-01
A technique was developed to calculate the stress intensity factor for multiple interacting cracks. The analysis was verified through comparison with accepted methods of calculating stress intensity factors. The technique was incorporated into a fatigue crack growth prediction model and used to predict the fatigue crack growth life for multiple-site damage (MSD). The analysis was verified through comparison with experiments conducted on uniaxially loaded flat panels with multiple cracks. Configuration with nearly equal and unequal crack distribution were examined. The fatigue crack growth predictions agreed within 20 percent of the experimental lives for all crack configurations considered.
NASA Technical Reports Server (NTRS)
Jackson, Mariea Dunn; Dischinger, Charles; Stambolian, Damon; Henderson, Gena
2012-01-01
Spacecraft and launch vehicle ground processing activities require a variety of unique human activities. These activities are being documented in a Primitive motion capture library. The Library will be used by the human factors engineering in the future to infuse real to life human activities into the CAD models to verify ground systems human factors requirements. As the Primitive models are being developed for the library the project has selected several current human factors issues to be addressed for the SLS and Orion launch systems. This paper explains how the Motion Capture of unique ground systems activities are being used to verify the human factors analysis requirements for ground system used to process the STS and Orion vehicles, and how the primitive models will be applied to future spacecraft and launch vehicle processing.
Zheng, Xing; Ernst, Mathias; Jekel, Martin
2010-05-01
Natural biofiltration processes have been verified as effective pre-treatment choice improving the performance of low-pressure membranes (MF/UF) in wastewater reclamation. In the present work, pilot-scale slow sand filtration (SSF) was used to simulate bank filtration at high filtration rates (from 0.25m/h to 0.5m/h) to filter secondary effluent prior to UF. The results showed that SSF improved the performance of UF to a large extent. Related to previous work biopolymers are considered as major dissolved organic foulants in treated wastewater. The removal of these organic foulants in slow sand filters and factors affecting the performance of SSF were investigated. It was observed that the removal of biopolymers took place mainly at the upper sand layer and was related to biological degradation. Tests on the degradability of biopolymers verified that they are biodegradable. Sixteen months monitoring of biopolymer concentration in the secondary effluent indicated that it varied seasonally. In winter season the concentration was much higher than during the summer months. Higher temperature and lower biopolymer concentration led to more effective foulants removal and more sustainable operation of SSF. During the whole experimental period, the performance of SSF was always better at filtration rate of 0.25m/h than at 0.5m/h. Under the present experimental conditions, SSF exhibited stable and effective biopolymer removal at temperatures higher than 15 degrees C, at biopolymer concentrations lower than 0.5mg C/L and with sufficient oxygen available.
Multiple UAV Cooperation for Wildfire Monitoring
NASA Astrophysics Data System (ADS)
Lin, Zhongjie
Wildfires have been a major factor in the development and management of the world's forest. An accurate assessment of wildfire status is imperative for fire management. This thesis is dedicated to the topic of utilizing multiple unmanned aerial vehicles (UAVs) to cooperatively monitor a large-scale wildfire. This is achieved through wildfire spreading situation estimation based on on-line measurements and wise cooperation strategy to ensure efficiency. First, based on the understanding of the physical characteristics of the wildfire propagation behavior, a wildfire model and a Kalman filter-based method are proposed to estimate the wildfire rate of spread and the fire front contour profile. With the enormous on-line measurements from on-board sensors of UAVs, the proposed method allows a wildfire monitoring mission to benefit from on-line information updating, increased flexibility, and accurate estimation. An independent wildfire simulator is utilized to verify the effectiveness of the proposed method. Second, based on the filter analysis, wildfire spreading situation and vehicle dynamics, the influence of different cooperation strategies of UAVs to the overall mission performance is studied. The multi-UAV cooperation problem is formulated in a distributed network. A consensus-based method is proposed to help address the problem. The optimal cooperation strategy of UAVs is obtained through mathematical analysis. The derived optimal cooperation strategy is then verified in an independent fire simulation environment to verify its effectiveness.
ERIC Educational Resources Information Center
Weber, Keith
2013-01-01
This paper presents the results of an experiment in which mathematicians were asked to rate how persuasive they found two empirical arguments. There were three key results from this study: (a) Participants judged an empirical argument as more persuasive if it verified that integers possessed an infrequent property than if it verified that integers…
Lira, Luis Henrique; Hirai, Flávio E; Oliveira, Marivaldo; Portellinha, Waldir; Nakano, Eliane Mayumi
2017-01-01
To identify the causes of a diffuse lamellar keratitis (DLK) outbreak using a systematic search tool in a case-control analysis. An Ishikawa diagram was used to guide physicians to determine the potential risk factors involved in this outbreak. Coherence between the occurrences and each possible cause listed in the diagram was verified, and the total number of eyes at risk was used to calculate the proportion of affected eyes. Multivariate analysis was performed using logistic regression to determine the independent effect of the risk factors, after controlling for confounders and test interactions. All DLK cases were reported in 2007 between June 13 and December 21; during this period, 3,698 procedures were performed. Of the 1,682 flap-related procedures, 204 eyes of 141 individuals presented with DLK. No direct relationship was observed between the occurrence of DLK and the presence of any specific factors; however, flap-lifting enhancements, procedures performed during the morning shift, and non-use of therapeutic contact lenses after the surgery were significantly related to higher occurrence percentages of this condition. The Ishikawa diagram, like most quality tools, is a visualization and knowledge organization tool. This systematization allowed the investigators to thoroughly assess all the possible causes of DLK outbreak. A clear view of the entire surgical logistics permitted even more rigid management of the main factors involved in the process and, as a result, highlighted factors that deserved attention. The case-control analysis on every factor raised by the Ishikawa diagram indicated that the commonly suspected factors such as biofilm contamination of the water reservoir in autoclaves, the air-conditioning filter system, glove powder, microkeratome motor oil, and gentian violet markers were not related to the outbreak.
A Novel Symmetrical Split Ring Resonator Based on Microstrip for Microwave Sensors
NASA Astrophysics Data System (ADS)
Alahnomi, Rammah A.; Zakaria, Z.; Ruslan, E.; Bahar, Amyrul Azuan Mohd
2016-02-01
In this paper, novel symmetrical split ring resonator (SSRR) is proposed as a suitable component for performance enhancement of microwave sensors. SSRR has been employed for enhancing the insertion loss of the microwave sensors. Using the same device area, we can achieve a high Q-factor of 141.54 from the periphery enhancement using Quasi-linear coupling SSRR, whereas loose coupling SSRR can achieve a Q-factor of 33.98 only. Using Quasi-linear coupling SSRR, the Q-factor is enhanced 4.16 times the loose coupling SSRR using the same device area. After the optimization was made, the SSRR sensor with loose coupling scheme has achieved a very high Qfactor value around 407.34 while quasi-linear scheme has achieved high Q-factor value of 278.78 at the same operating frequency with smaller insertion loss. Spurious passbands at 1st, 2nd, 3rd, and 4th harmonics have been completely suppressed well above -20 dB rejection level without visible changes in the passband filter characteristics. The most significant of using SSRR is to be used for various industrial applications such as food industry, quality control, bio-sensing medicine and pharmacy. The simulation result that Quasi-linear coupling SSRR is a viable candidate for the performance enhancement of microwave sensors has been verified.
NASA Astrophysics Data System (ADS)
Uhlemann, Sebastian; Wilkinson, Paul B.; Maurer, Hansruedi; Wagner, Florian M.; Johnson, Timothy C.; Chambers, Jonathan E.
2018-07-01
Within geoelectrical imaging, the choice of measurement configurations and electrode locations is known to control the image resolution. Previous work has shown that optimized survey designs can provide a model resolution that is superior to standard survey designs. This paper demonstrates a methodology to optimize resolution within a target area, while limiting the number of required electrodes, thereby selecting optimal electrode locations. This is achieved by extending previous work on the `Compare-R' algorithm, which by calculating updates to the resolution matrix optimizes the model resolution in a target area. Here, an additional weighting factor is introduced that allows to preferentially adding measurement configurations that can be acquired on a given set of electrodes. The performance of the optimization is tested on two synthetic examples and verified with a laboratory study. The effect of the weighting factor is investigated using an acquisition layout comprising a single line of electrodes. The results show that an increasing weight decreases the area of improved resolution, but leads to a smaller number of electrode positions. Imaging results superior to a standard survey design were achieved using 56 per cent fewer electrodes. The performance was also tested on a 3-D acquisition grid, where superior resolution within a target at the base of an embankment was achieved using 22 per cent fewer electrodes than a comparable standard survey. The effect of the underlying resistivity distribution on the performance of the optimization was investigated and it was shown that even strong resistivity contrasts only have minor impact. The synthetic results were verified in a laboratory tank experiment, where notable image improvements were achieved. This work shows that optimized surveys can be designed that have a resolution superior to standard survey designs, while requiring significantly fewer electrodes. This methodology thereby provides a means for improving the efficiency of geoelectrical imaging.
NASA Astrophysics Data System (ADS)
Uhlemann, Sebastian; Wilkinson, Paul B.; Maurer, Hansruedi; Wagner, Florian M.; Johnson, Timothy C.; Chambers, Jonathan E.
2018-03-01
Within geoelectrical imaging, the choice of measurement configurations and electrode locations is known to control the image resolution. Previous work has shown that optimized survey designs can provide a model resolution that is superior to standard survey designs. This paper demonstrates a methodology to optimize resolution within a target area, while limiting the number of required electrodes, thereby selecting optimal electrode locations. This is achieved by extending previous work on the `Compare-R' algorithm, which by calculating updates to the resolution matrix optimizes the model resolution in a target area. Here, an additional weighting factor is introduced that allows to preferentially adding measurement configurations that can be acquired on a given set of electrodes. The performance of the optimization is tested on two synthetic examples and verified with a laboratory study. The effect of the weighting factor is investigated using an acquisition layout comprising a single line of electrodes. The results show that an increasing weight decreases the area of improved resolution, but leads to a smaller number of electrode positions. Imaging results superior to a standard survey design were achieved using 56 per cent fewer electrodes. The performance was also tested on a 3D acquisition grid, where superior resolution within a target at the base of an embankment was achieved using 22 per cent fewer electrodes than a comparable standard survey. The effect of the underlying resistivity distribution on the performance of the optimization was investigated and it was shown that even strong resistivity contrasts only have minor impact. The synthetic results were verified in a laboratory tank experiment, where notable image improvements were achieved. This work shows that optimized surveys can be designed that have a resolution superior to standard survey designs, while requiring significantly fewer electrodes. This methodology thereby provides a means for improving the efficiency of geoelectrical imaging.
Improved safety of retinal photocoagulation with a shaped beam and modulated pulse
NASA Astrophysics Data System (ADS)
Sramek, Christopher; Brown, Jefferson; Paulus, Yannis M.; Nomoto, Hiroyuki; Palanker, Daniel
2010-02-01
Shorter pulse durations help confine thermal damage during retinal photocoagulation, decrease treatment time and minimize pain. However, safe therapeutic window (the ratio of threshold powers for rupture and mild coagulation) decreases with shorter exposures. A ring-shaped beam enables safer photocoagulation than conventional beams by reducing the maximum temperature in the center of the spot. Similarly, a temporal pulse modulation decreasing its power over time improves safety by maintaining constant temperature for a significant portion of the pulse. Optimization of the beam and pulse shapes was performed using a computational model. In vivo experiments were performed to verify the predicted improvement. With each of these approaches, the pulse duration can be decreased by a factor of two, from 20 ms down to 10 ms while maintaining the same therapeutic window.
Cross-Layer Design for Space-Time coded MIMO Systems over Rice Fading Channel
NASA Astrophysics Data System (ADS)
Yu, Xiangbin; Zhou, Tingting; Liu, Xiaoshuai; Yin, Xin
A cross-layer design (CLD) scheme for space-time coded MIMO systems over Rice fading channel is presented by combining adaptive modulation and automatic repeat request, and the corresponding system performance is investigated well. The fading gain switching thresholds subject to a target packet error rate (PER) and fixed power constraint are derived. According to these results, and using the generalized Marcum Q-function, the calculation formulae of the average spectrum efficiency (SE) and PER of the system with CLD are derived. As a result, closed-form expressions for average SE and PER are obtained. These expressions include some existing expressions in Rayleigh channel as special cases. With these expressions, the system performance in Rice fading channel is evaluated effectively. Numerical results verify the validity of the theoretical analysis. The results show that the system performance in Rice channel is effectively improved as Rice factor increases, and outperforms that in Rayleigh channel.
Performance Evaluation and Analysis for Gravity Matching Aided Navigation.
Wu, Lin; Wang, Hubiao; Chai, Hua; Zhang, Lu; Hsu, Houtse; Wang, Yong
2017-04-05
Simulation tests were accomplished in this paper to evaluate the performance of gravity matching aided navigation (GMAN). Four essential factors were focused in this study to quantitatively evaluate the performance: gravity database (DB) resolution, fitting degree of gravity measurements, number of samples in matching, and gravity changes in the matching area. Marine gravity anomaly DB derived from satellite altimetry was employed. Actual dynamic gravimetry accuracy and operating conditions were referenced to design the simulation parameters. The results verified that the improvement of DB resolution, gravimetry accuracy, number of measurement samples, or gravity changes in the matching area generally led to higher positioning accuracies, while the effects of them were different and interrelated. Moreover, three typical positioning accuracy targets of GMAN were proposed, and the conditions to achieve these targets were concluded based on the analysis of several different system requirements. Finally, various approaches were provided to improve the positioning accuracy of GMAN.
Performance Evaluation and Analysis for Gravity Matching Aided Navigation
Wu, Lin; Wang, Hubiao; Chai, Hua; Zhang, Lu; Hsu, Houtse; Wang, Yong
2017-01-01
Simulation tests were accomplished in this paper to evaluate the performance of gravity matching aided navigation (GMAN). Four essential factors were focused in this study to quantitatively evaluate the performance: gravity database (DB) resolution, fitting degree of gravity measurements, number of samples in matching, and gravity changes in the matching area. Marine gravity anomaly DB derived from satellite altimetry was employed. Actual dynamic gravimetry accuracy and operating conditions were referenced to design the simulation parameters. The results verified that the improvement of DB resolution, gravimetry accuracy, number of measurement samples, or gravity changes in the matching area generally led to higher positioning accuracies, while the effects of them were different and interrelated. Moreover, three typical positioning accuracy targets of GMAN were proposed, and the conditions to achieve these targets were concluded based on the analysis of several different system requirements. Finally, various approaches were provided to improve the positioning accuracy of GMAN. PMID:28379178
Enhanced thermoelectric performance of graphene nanoribbon-based devices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hossain, Md Sharafat, E-mail: hossain@student.unimelb.edu.au; Huynh, Duc Hau; Nguyen, Phuong Duc
There have been numerous theoretical studies on exciting thermoelectric properties of graphene nano-ribbons (GNRs); however, most of these studies are mainly based on simulations. In this work, we measure and characterize the thermoelectric properties of GNRs and compare the results with theoretical predictions. Our experimental results verify that nano-structuring and patterning graphene into nano-ribbons significantly enhance its thermoelectric power, confirming previous predictions. Although patterning results in lower conductance (G), the overall power factor (S{sup 2}G) increases for nanoribbons. We demonstrate that edge roughness plays an important role in achieving such an enhanced performance and support it through first principles simulations.more » We show that uncontrolled edge roughness, which is considered detrimental in GNR-based electronic devices, leads to enhanced thermoelectric performance of GNR-based thermoelectric devices. The result validates previously reported theoretical studies of GNRs and demonstrates the potential of GNRs for the realization of highly efficient thermoelectric devices.« less
Study on dynamic performance of SOFC
NASA Astrophysics Data System (ADS)
Zhan, Haiyang; Liang, Qianchao; Wen, Qiang; Zhu, Runkai
2017-05-01
In order to solve the problem of real-time matching of load and fuel cell power, it is urgent to study the dynamic response process of SOFC in the case of load mutation. The mathematical model of SOFC is constructed, and its performance is simulated. The model consider the influence factors such as polarization effect, ohmic loss. It also takes the diffusion effect, thermal effect, energy exchange, mass conservation, momentum conservation. One dimensional dynamic mathematical model of SOFC is constructed by using distributed lumped parameter method. The simulation results show that the I-V characteristic curves are in good agreement with the experimental data, and the accuracy of the model is verified. The voltage response curve, power response curve and the efficiency curve are obtained by this way. It lays a solid foundation for the research of dynamic performance and optimal control in power generation system of high power fuel cell stack.
[Developing Perceived Competence Scale (PCS) for Adolescents].
Özer, Arif; Gençtanirim Kurt, Dilek; Kizildağ, Seval; Demırtaş Zorbaz, Selen; Arici Şahın, Fatma; Acar, Tülin; Ergene, Tuncay
2016-01-01
In this study, Perceived Competence Scale was developed to measure high school students' perceived competence. Scale development process was verified on three different samples. Participants of the research are some high school students in 2011-2012 academic terms from Ankara. Participants' numbers are incorporated in exploratory factor analysis, confirmatory factor analysis and test-retest reliability respectively, as follows: 372, 668 and 75. Internal consistency coefficients (Cronbach's and stratified α) are calculated separately for each group. For data analysis Factor 8.02 and LISREL 8.70 package programs were used. According to results of the analyses, internal consistency coefficients (α) are .90 - .93 for academic competence, .82 - .86 for social competence in the samples that exploratory and confirmatory factor analysis performed. For the whole scale internal consistency coefficient (stratified α) is calculated as .91. As a result of test-retest reliability, adjusted correlation coefficients (r) are .94 for social competence and .90 for academic competence. In addition, to fit indexes and regression weights obtained from factor analysis, findings related convergent and discriminant validity, indicating that competence can be addressed in two dimensions which are academic (16 items) and social (14 items).
Strategic factors for the sustainability of a health intervention at municipal level of Brazil.
Oliveira, Sydia Rosana de Araujo; Medina, Maria Guadalupe; Figueiró, Ana Cláudia; Potvin, Louise
2017-07-27
The present study aims to describe the evolution of an intervention, using a methodology that adopts the critical event as the unit of analysis, and to identify strategic factors that facilitate the continuation of the interventions. Six critical events were identified: dispute care models for health; area of advice: dispute field; change policy; break of interorganizational relations; lack of physical structure and turnover of staff; difficulty in organizing practices in the work process. these are developed into strategic factors: enabling network of allies; meetings and educational activities/building capacity; benefits perceived by community members; mobilization of key actors; intervention's compatibility with the government's vision; restoration of interrelationship; and stability of the workforce. These strategic factors form a group of interrelated conditions that provide the strengthened linkages between elements in the intervention, supporting the hypothesis that they collaborate for the sustainability of the interventions in health. Tracking down the transformations of an intervention set by the critical events, it was verified that these factors performed a protective role at times of changes in the intervention process.
NASA Astrophysics Data System (ADS)
Jiang, Qingfeng; Zhuang, Ming; Zhang, Qiyong; Zhu, Zhigang; Geng, Maofei; Sheng, Linhai; Zhu, Ping
2018-04-01
Efficient and compact plate-fin heat exchangers are critical for large-scale helium liquefaction/refrigeration systems as they constitute major part in the cold box. This study experimentally explores the heat transfer and pressure drop behaviors of helium gas at low temperature in four types of plate-fin channels, namely offset-strip and perforated fins, with different geometrical parameters. A series of cryogenic experiments at approximately liquid nitrogen temperature are carried out to measure the Colburn j factors and Fanning friction f factors with a wide range of Reynolds number. Besides, to reveal the performance variations under different operating temperatures, comparative experiments respectively conducted at room temperature and liquid nitrogen temperature are implemented. The results show that in comparison with the performance data at room temperature, most of j factors are relatively smaller perhaps because the lower aluminum thermal conductivity and higher Prandtl Number at low temperature. Meanwhile, the f factors corresponding to cryogenic conditions exhibit slightly larger even though the core pressure drops show considerable reductions. In contrast to the calculated results from the frequently-used performance curves (Chen and Shen, 1993), the Root Mean Squared Errors of j and f values are correlated within 8.38% and 6.97% for one perforated fin core, 41.29% and 34.97% for three OSF cores, respectively. For OSFs, further comparisons with the previous empirical correlations from literatures are conducted to verify the accuracy of each correlation. Generally, most of the calculated results predict acceptably within the deviations of ±25% for the j factors, while the predicted results express relatively large deviations for the f factors. Therefore, it may be revealed that most of the existing correlations were not able to accurately predict the experimental data in consideration of the performance differences under realistic cryogenic operating conditions, which could have significant influences during the design process of cryogenic heat exchangers.
Prediction of road traffic death rate using neural networks optimised by genetic algorithm.
Jafari, Seyed Ali; Jahandideh, Sepideh; Jahandideh, Mina; Asadabadi, Ebrahim Barzegari
2015-01-01
Road traffic injuries (RTIs) are realised as a main cause of public health problems at global, regional and national levels. Therefore, prediction of road traffic death rate will be helpful in its management. Based on this fact, we used an artificial neural network model optimised through Genetic algorithm to predict mortality. In this study, a five-fold cross-validation procedure on a data set containing total of 178 countries was used to verify the performance of models. The best-fit model was selected according to the root mean square errors (RMSE). Genetic algorithm, as a powerful model which has not been introduced in prediction of mortality to this extent in previous studies, showed high performance. The lowest RMSE obtained was 0.0808. Such satisfactory results could be attributed to the use of Genetic algorithm as a powerful optimiser which selects the best input feature set to be fed into the neural networks. Seven factors have been known as the most effective factors on the road traffic mortality rate by high accuracy. The gained results displayed that our model is very promising and may play a useful role in developing a better method for assessing the influence of road traffic mortality risk factors.
Factors and competitiveness analysis in rare earth mining, new methodology: case study from Brazil.
Silva, Gustavo A; Petter, Carlos O; Albuquerque, Nelson R
2018-03-01
Rare earths are increasingly being applied in high-tech industries, such as green energy (e.g. wind power), hybrid cars, electric cars, permanent high-performance magnets, superconductors, luminophores and many other industrial sectors involved in modern technologies. Given that China dominates this market and imposes restrictions on production and exports whenever opportunities arise, it is becoming more and more challenging to develop business ventures in this sector. Several initiatives were taken to prospect new resources and develop the production chain, including the mining of these mineral assets around the world, but some factors of uncertainties, including current low prices, increased the challenge of transforming the current resources into deposits or productive mines. Thus, analyzing the competitiveness of advanced projects becomes indispensable. This work has the objective of introducing a new methodology of competitiveness analysis, where some variables are considered as main factors that can contribute strongly to make unfeasible a mining enterprise for the use of rare earth elements (REE) with this methodology, which is quite practical and reproducible, it was possible to verify some real facts, such as: the fact that the Lynas Mount Weld CLD (AUS) Project is resilient to the uncertainties of the RE sector, at the same time as the Molycorp Project is facing major financial difficulties (under judicial reorganization). It was also possible to verify that the Araxá Project of CBMM in Brazil is one of the most competitive in this country. Thus, we contribute to the existing literature, providing a new methodology for competitiveness analysis in rare earth mining.
Flight Motor Set 360T010 (STS-31R). Volume 1: System Overview
NASA Technical Reports Server (NTRS)
Garecht, Diane
1990-01-01
Flight motor set 360T010 was launched at approximately 7:34 a.m. CST (090:114:12:33:50.990 GMT) on 24 Apr. 1990 after one launch attempt (attempt on 10 Apr. 1990 was scrubbed following an indication of erratic operation of the Orbiter No. 1 Auciliary Power Unit No. 1). There were no problems with the solid rocket motor launches, overall motor performance was excellent. There were no debris concerns from either motor. Nearly all ballistic contract end item specification parameters were verified with the exception of ignition interval, pressure rise rate, and ignition time thrust imbalance. These could not be verified due to elimination of developmental flight instrumentation on 360L004 (STS-30R) and subsequent, but low sample rate data that were available showed nominal propulsion performance. All ballistic and mass property parameters that could be assessed closely matched the predicted values and were well within the required contract end item specification levels. All field joint heaters and igniter joint heaters performed without anomalies. Evaluation of the ground environment instrumentation measurements again verified thermal model analysis data and showed agreement with predicted environmental effects. No launch commit criteria violations occurred. Postflight inspection again verified nominal performance of the insulation, phenolics, metal parts, and seals. Postflight evaluation indicated both nozzles performed as expected during flight. All combustion gas was contained by insulation in the field and case-to-nozzle joints.
Flight motor set 360L007 (STS-33R)
NASA Technical Reports Server (NTRS)
Garecht, Diane
1990-01-01
Flight motor set 360L007 was launched as part of NASA space shuttle mission STS-33R. As with all previous redesigned solid rocket motor launches, overall motor performance was excellent. There were no debris concerns for either motor. Both motors exhibited unbonds on one factory joint weatherseal. All ballistics contract end item specification parameters were verified, with the exception of ignition interval and rise rates. Ignition interval and rise rates could not be verified due to the elimination of developmental flight instrumentation from fourth flight and subsequent, but the low sample rate data that were available showed nominal propulsion performance. All ballistic and mass property parameters closely matched the predicted values and were well within the required contract end item specification levels that could be assessed. All 108 Ground Environment Instrumentation (GEI) measurements performed properly throughout the prelaunch phase. Evaluation of the GEI measurements again verified thermal model analysis data and showed agreement with predicted environmental effects. No launch commit criteria thermal violations occurred. All joint heaters operated normally, but a high voltage reading was noted on the left hand aft heater, which was immediately determined to be a voltage sensor error and not a heater anomaly due to no current increase. Postflight inspection again verified superior performance of the insulation, phenolics, metal parts, and seals. Postflight evaluation indicated both nozzles performed as expected during flight. All combustion gas was contained by insulation in the field and case-to-nozzle joints.
Calibration of X-Ray Observatories
NASA Technical Reports Server (NTRS)
Weisskopf, Martin C.; L'Dell, Stephen L.
2011-01-01
Accurate calibration of x-ray observatories has proved an elusive goal. Inaccuracies and inconsistencies amongst on-ground measurements, differences between on-ground and in-space performance, in-space performance changes, and the absence of cosmic calibration standards whose physics we truly understand have precluded absolute calibration better than several percent and relative spectral calibration better than a few percent. The philosophy "the model is the calibration" relies upon a complete high-fidelity model of performance and an accurate verification and calibration of this model. As high-resolution x-ray spectroscopy begins to play a more important role in astrophysics, additional issues in accurately calibrating at high spectral resolution become more evident. Here we review the challenges of accurately calibrating the absolute and relative response of x-ray observatories. On-ground x-ray testing by itself is unlikely to achieve a high-accuracy calibration of in-space performance, especially when the performance changes with time. Nonetheless, it remains an essential tool in verifying functionality and in characterizing and verifying the performance model. In the absence of verified cosmic calibration sources, we also discuss the notion of an artificial, in-space x-ray calibration standard. 6th
Introduction to the Navigation Team: Johnson Space Center EG6 Internship
NASA Technical Reports Server (NTRS)
Gualdoni, Matthew
2017-01-01
The EG6 navigation team at NASA Johnson Space Center, like any team of engineers, interacts with the engineering process from beginning to end; from exploring solutions to a problem, to prototyping and studying the implementations, all the way to polishing and verifying a final flight-ready design. This summer, I was privileged enough to gain exposure to each of these processes, while also getting to truly experience working within a team of engineers. My summer can be broken up into three projects: i) Initial study and prototyping: investigating a manual navigation method that can be utilized onboard Orion in the event of catastrophic failure of navigation systems; ii) Finalizing and verifying code: altering a software routine to improve its robustness and reliability, as well as designing unit tests to verify its performance; and iii) Development of testing equipment: assisting in developing and integrating of a high-fidelity testbed to verify the performance of software and hardware.
Dynamic modeling of porous heterogeneous micro/nanobeams
NASA Astrophysics Data System (ADS)
Ebrahimi, Farzad; Jafari, Ali; Reza Barati, Mohammad
2017-12-01
In the present paper, the thermo-mechanical vibration characteristics of a functionally graded (FG) porous microbeam subjected to various types of thermal loadings are investigated based on modified couple stress theory and exact position of neutral axis. The FG micro/nanobeam is modeled via a refined hyperbolic beam theory in which the shear deformation effect is verified without the shear correction factor. A modified power-law distribution which contains porosity volume fraction is used to describe the graded material properties of the FG micro/nanobeam. The temperature field has uniform, linear and nonlinear distributions across the thickness. The governing equations and the related boundary conditions are derived by Hamilton's principle and they are solved applying an analytical solution which satisfies various boundary conditions. A comparison study is performed to verify the present formulation with the known data in the literature and a good agreement is observed. The parametric study covered in this paper includes several parameters, such as thermal loadings, porosity volume fraction, power-law exponents, slenderness ratio, scale parameter and various boundary conditions on natural frequencies of porous FG micro/nanobeams in detail.
Protecting Files Hosted on Virtual Machines With Out-of-Guest Access Control
2017-12-01
analyzes the design and methodology of the implemented mechanism, while Chapter 4 explains the test methodology, test cases, and performance testing ...SACL, we verify that the user or group accessing the file has sufficient permissions. If that is correct, the callback function returns control to...ferify. In the first section, we validate our design of ferify. Next, we explain the tests we performed to verify that ferify has the results we expected
Peiper, Nicholas; Lee, Alexander; Lindsay, Stephanie; Drashner, Nathan; Wing, Janeena
2016-06-01
Since 2013, Idaho has been building capacity and infrastructure through the Strategic Prevention Framework State Incentive Grant to prevent substance abuse and related problems, namely psychiatric morbidity. As this federal initiative requires states to engage in data-driven strategic planning at the state and community levels, clinically validated instruments are particularly valuable in the context of school surveys that have limited space and require timely administration. Thus, the K6 scale was included on the 2014 Idaho Youth Prevention Survey as a measure of nonspecific psychological distress. To verify the unidimensional structure of the K6, principal axis and confirmatory factor analyses were performed in a school-based sample of Idaho students (n = 12,150). A series of multigroup confirmatory factor analyses were then performed to evaluate measurement invariance across gender, age, and race. Overall, the prevalence of serious psychological distress in the past 30 days was 17.2% in Idaho. Factor analyses confirmed the 1-factor solution of the K6. Four levels of measurement invariance were demonstrated across gender, age, and race. Together, these results further illustrate the construct validity of the K6 for use in adolescent populations. Other states are encouraged to include the K6 on their school surveys to facilitate policy planning and resource allocation as well as generate cross-state comparisons. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Factor Analysis of Traffic Safety in Urban Roads Based on FTA-LEC
NASA Astrophysics Data System (ADS)
Shuicheng, TIAN; Xingbo, YANG; Xiaoqing, SHEN; Detao, ZHANG
2018-05-01
In order to reduce the number and the loss of urban road traffic accidents in our country, improve the safety of road traffic, a statistical analysis of the research report on major road traffic accidents in 2016 was conducted. The risk factors affecting urban road traffic in China were analyzed by using FTA to find the basic hidden events. Secondly, the risk value of the identified hidden danger events were calculated and classified into four levels I, II, III and IV through the LEC evaluation method. Finally, the graded results of risk factors are verified through a case of specific accidents in Beijing. The results show that: the case verified the scientificalness and effectiveness of hazard classification and provided guidance for urban road traffic management.
Performance optimization of an online retailer by a unique online resilience engineering algorithm
NASA Astrophysics Data System (ADS)
Azadeh, A.; Salehi, V.; Salehi, R.; Hassani, S. M.
2018-03-01
Online shopping has become more attractive and competitive in electronic markets. Resilience engineering (RE) can help such systems divert to the normal state in case of encountering unexpected events. This study presents a unique online resilience engineering (ORE) approach for online shopping systems and customer service performance. Moreover, this study presents a new ORE algorithm for the performance optimisation of an actual online shopping system. The data are collected by standard questionnaires from both expert employees and customers. The problem is then formulated mathematically using data envelopment analysis (DEA). The results show that the design process which is based on ORE is more efficient than the conventional design approach. Moreover, on-time delivery is the most important factor from the personnel's perspective. In addition, according to customers' view, trust, security and good quality assurance are the most effective factors during transactions. This is the first study that introduces ORE for electronic markets. Second, it investigates impact of RE on online shopping through DEA and statistical methods. Third, a practical approach is employed in this study and it may be used for similar online shops. Fourth, the results are verified and validated through complete sensitivity analysis.
Verifying the Performance of RTDs in Nuclear Power Plants
NASA Astrophysics Data System (ADS)
Hashemian, H. M.
2003-09-01
This paper describes a number of techniques that have been developed for nuclear power plants to ensure that optimum steady-state and transient performance is achieved with the resistance temperature detectors (RTDs) that are used in the plant for critical temperature measurements. This includes precision laboratory calibration of RTDs, the Loop Current Step Response (LCSR) method for in-situ response time measurements, a cross calibration technique to verify the steady-state performance of RTDs as installed in the plant, and the Time Domain Reflectometry (TDR) test that is used to identify the location of a problem along RTD cables.
Assessment of seismic design response factors of concrete wall buildings
NASA Astrophysics Data System (ADS)
Mwafy, Aman
2011-03-01
To verify the seismic design response factors of high-rise buildings, five reference structures, varying in height from 20- to 60-stories, were selected and designed according to modern design codes to represent a wide range of concrete wall structures. Verified fiber-based analytical models for inelastic simulation were developed, considering the geometric nonlinearity and material inelasticity of the structural members. The ground motion uncertainty was accounted for by employing 20 earthquake records representing two seismic scenarios, consistent with the latest understanding of the tectonic setting and seismicity of the selected reference region (UAE). A large number of Inelastic Pushover Analyses (IPAs) and Incremental Dynamic Collapse Analyses (IDCAs) were deployed for the reference structures to estimate the seismic design response factors. It is concluded that the factors adopted by the design code are adequately conservative. The results of this systematic assessment of seismic design response factors apply to a wide variety of contemporary concrete wall buildings with various characteristics.
Seol, Daehee; Park, Seongjae; Varenyk, Olexandr V; Lee, Shinbuhm; Lee, Ho Nyung; Morozovska, Anna N; Kim, Yunseok
2016-07-28
Hysteresis loop analysis via piezoresponse force microscopy (PFM) is typically performed to probe the existence of ferroelectricity at the nanoscale. However, such an approach is rather complex in accurately determining the pure contribution of ferroelectricity to the PFM. Here, we suggest a facile method to discriminate the ferroelectric effect from the electromechanical (EM) response through the use of frequency dependent ac amplitude sweep with combination of hysteresis loops in PFM. Our combined study through experimental and theoretical approaches verifies that this method can be used as a new tool to differentiate the ferroelectric effect from the other factors that contribute to the EM response.
Enhanced thermoelectric performance of amorphous Nb based oxynitrides
NASA Astrophysics Data System (ADS)
Music, Denis; Geyer, Richard W.; Hans, Marcus
2015-12-01
Using density functional theory, amorphous Nb0.27Ru0.06O0.56N0.10 was designed to facilitate a combination of an enhanced Seebeck coefficient and low electrical resistivity. Based on a positive Cauchy pressure, ductile behavior is expected. To verify these predictions, the transport and mechanical properties of amorphous thin films were evaluated. Metallic electrical resistivity and the Seebeck coefficient of -94 μV K-1 are obtained, which is consistent with our predictions. As there is no crack formation, these samples can be perceived as ductile. We demonstrate that the power factor can be increased by an order of magnitude, while keeping the thermal fatigue low.
Seol, Daehee; Park, Seongjae; Varenyk, Olexandr V.; Lee, Shinbuhm; Lee, Ho Nyung; Morozovska, Anna N.; Kim, Yunseok
2016-01-01
Hysteresis loop analysis via piezoresponse force microscopy (PFM) is typically performed to probe the existence of ferroelectricity at the nanoscale. However, such an approach is rather complex in accurately determining the pure contribution of ferroelectricity to the PFM. Here, we suggest a facile method to discriminate the ferroelectric effect from the electromechanical (EM) response through the use of frequency dependent ac amplitude sweep with combination of hysteresis loops in PFM. Our combined study through experimental and theoretical approaches verifies that this method can be used as a new tool to differentiate the ferroelectric effect from the other factors that contribute to the EM response. PMID:27466086
The Use of Air Injection Nozzles for the Forced Excitation of Axial Compressor Blades
NASA Astrophysics Data System (ADS)
Raubenheimer, G. A.; van der Spuy, S. J.; von Backström, T. W.
2013-03-01
Turbomachines are exposed to many factors which may cause failure of its components. One of these, high cycle fatigue, can be caused by blade flutter. This paper evaluates the use of an air injection nozzle as a means of exciting vibrations on the first stage rotor blades of a rotating axial compressor. Unsteady simulations of the excitation velocity perturbations were performed on the Computational Fluid Dynamics (CFD) software, Numeca FINE™/Turbo. Experimental testing on a three-stage, low Mach number axial flow compressor provided data that was used to implement boundary conditions and to verify certain aspects of the unsteady simulation results.
Small scale sequence automation pays big dividends
NASA Technical Reports Server (NTRS)
Nelson, Bill
1994-01-01
Galileo sequence design and integration are supported by a suite of formal software tools. Sequence review, however, is largely a manual process with reviewers scanning hundreds of pages of cryptic computer printouts to verify sequence correctness. Beginning in 1990, a series of small, PC based sequence review tools evolved. Each tool performs a specific task but all have a common 'look and feel'. The narrow focus of each tool means simpler operation, and easier creation, testing, and maintenance. Benefits from these tools are (1) decreased review time by factors of 5 to 20 or more with a concomitant reduction in staffing, (2) increased review accuracy, and (3) excellent returns on time invested.
Design and performance test of a MEMS vibratory gyroscope with a novel AGC force rebalance control
NASA Astrophysics Data System (ADS)
Sung, Woon-Tahk; Sung, Sangkyung; Lee, Jang Gyu; Kang, Taesam
2007-10-01
In this paper, the development and performance test results of a laterally oscillating MEMS gyroscope using a novel force rebalance control strategy are presented. The micromachined structure and electrodes are fabricated using the deep reactive ion etching (DRIE) and anodic wafer bonding process. The high quality factor required for the resonance-based sensor is achieved using a vacuum-sealed device package. A systematic design approach of the force rebalance control is applied via a modified automatic gain control (AGC) method. The rebalance control design takes advantages of a novel AGC loop modification, which allows the approximation of the system's dynamics into a simple linear form. Using the proposed modification of AGC and the rebalance strategy that maintains a biased oscillation, a number of performance improvements including bandwidth extension and widened operating range were observed to be achieved. Finally, the experimental results of the gyroscope's practical application verify the feasibility and performance of the developed sensor.
ERIC Educational Resources Information Center
Burk, Erlan
2012-01-01
Aerospace companies needed additional research on technology-based training to verify expectations when enhancing human capital through online systems analysis training. The research for online systems analysis training provided aerospace companies a means to verify expectations for systems analysis technology-based training on business…
Removing non-stationary noise in spectrum sensing using matrix factorization
NASA Astrophysics Data System (ADS)
van Bloem, Jan-Willem; Schiphorst, Roel; Slump, Cornelis H.
2013-12-01
Spectrum sensing is key to many applications like dynamic spectrum access (DSA) systems or telecom regulators who need to measure utilization of frequency bands. The International Telecommunication Union (ITU) recommends a 10 dB threshold above the noise to decide whether a channel is occupied or not. However, radio frequency (RF) receiver front-ends are non-ideal. This means that the obtained data is distorted with noise and imperfections from the analog front-end. As part of the front-end the automatic gain control (AGC) circuitry mainly affects the sensing performance as strong adjacent signals lift the noise level. To enhance the performance of spectrum sensing significantly we focus in this article on techniques to remove the noise caused by the AGC from the sensing data. In order to do this we have applied matrix factorization techniques, i.e., SVD (singular value decomposition) and NMF (non-negative matrix factorization), which enables signal space analysis. In addition, we use live measurement results to verify the performance and to remove the effects of the AGC from the sensing data using above mentioned techniques, i.e., applied on block-wise available spectrum data. In this article it is shown that the occupancy in the industrial, scientific and medical (ISM) band, obtained by using energy detection (ITU recommended threshold), can be an overestimation of spectrum usage by 60%.
Piecewise compensation for the nonlinear error of fiber-optic gyroscope scale factor
NASA Astrophysics Data System (ADS)
Zhang, Yonggang; Wu, Xunfeng; Yuan, Shun; Wu, Lei
2013-08-01
Fiber-Optic Gyroscope (FOG) scale factor nonlinear error will result in errors in Strapdown Inertial Navigation System (SINS). In order to reduce nonlinear error of FOG scale factor in SINS, a compensation method is proposed in this paper based on curve piecewise fitting of FOG output. Firstly, reasons which can result in FOG scale factor error are introduced and the definition of nonlinear degree is provided. Then we introduce the method to divide the output range of FOG into several small pieces, and curve fitting is performed in each output range of FOG to obtain scale factor parameter. Different scale factor parameters of FOG are used in different pieces to improve FOG output precision. These parameters are identified by using three-axis turntable, and nonlinear error of FOG scale factor can be reduced. Finally, three-axis swing experiment of SINS verifies that the proposed method can reduce attitude output errors of SINS by compensating the nonlinear error of FOG scale factor and improve the precision of navigation. The results of experiments also demonstrate that the compensation scheme is easy to implement. It can effectively compensate the nonlinear error of FOG scale factor with slightly increased computation complexity. This method can be used in inertial technology based on FOG to improve precision.
Comments on the crusade against the causal efficacy of human thought.
Bandura, A
1995-09-01
Hawkins reiterates the familiar behavioristic doctrine that psychology should banish factors that cannot be directly observed. He seems to be unaware that the very operant theory he is espousing is heavily invested in internal determinants that do not lend themselves to direct observation. Because behavior is often unaffected by its immediate situational antecedents and consequences, operant analysts are turning increasingly to internalized determinants of behavior, such as the residues of past reinforcements. These internalized determinants are not directly observable or measurable. They are inferred organismic states. Hawkins invokes the standard behavioristic arguments that, like other cognitive events, beliefs of personal efficacy are epiphenomenal by-products of conditioned responses. The paradigms used to verify the causal contribution of efficacy beliefs to performance renders this claim empirically baseless. Efficacy beliefs are systematically raised to differential levels by means that involve no performances or by bogus feedback that is either unrelated to performance or is contrary to performance. In none of these paradigms are instated efficacy beliefs reflections of performance, but they are uniformly good predictors of subsequent performance. Epiphenomenal assertions are self-destruct arguments.
Lacbawan, Felicitas L; Weck, Karen E; Kant, Jeffrey A; Feldman, Gerald L; Schrijver, Iris
2012-01-01
The number of clinical laboratories introducing various molecular tests to their existing test menu is continuously increasing. Prior to offering a US Food and Drug Administration-approved test, it is necessary that performance characteristics of the test, as claimed by the company, are verified before the assay is implemented in a clinical laboratory. To provide an example of the verification of a specific qualitative in vitro diagnostic test: cystic fibrosis carrier testing using the Luminex liquid bead array (Luminex Molecular Diagnostics, Inc, Toronto, Ontario). The approach used by an individual laboratory for verification of a US Food and Drug Administration-approved assay is described. Specific verification data are provided to highlight the stepwise verification approach undertaken by a clinical diagnostic laboratory. Protocols for verification of in vitro diagnostic assays may vary between laboratories. However, all laboratories must verify several specific performance specifications prior to implementation of such assays for clinical use. We provide an example of an approach used for verifying performance of an assay for cystic fibrosis carrier screening.
Adaptive photoacoustic imaging using the Mallart-Fink focusing factor
NASA Astrophysics Data System (ADS)
Li, Meng-Lin
2008-02-01
Focusing errors caused by sound velocity heterogeneities widen the mainlobe and elevate the sidelobes, thus degrading both spatial and contrast resolutions in photoacoustic imaging. We propose an adaptive array-based photoacoustic imaging technique that uses the Mallart-Fink (MF) focusing factor weighting to reduce the effect of such focusing errors. The definition of the MF focusing factor indicates that the MF focusing factor at the main lobe of the point-spread function is high (close to 1, without speckle noise being present, which is the case in photoacoustic imaging), whereas it is low at the sidelobes. Based on this property, the elevated sidelobes caused by sound velocity heterogeneities in the tissue can be suppressed after being multiplied by the corresponding map of the MF focusing factor on each imaging point; thus the focusing quality can be improved. This technique makes no assumption of sources of focusing errors and directly suppresses the unwanted sidelobe contributions. Numerical experiments with near field phase screen and displaced phase screen models were performed here to verify the proposed adaptive weighting technique. The effect of the signal-to-noise ratio on the MF focusing factor is also discussed.
[Quantitative parameters to evaluate the publication of scientific papers].
Petroianu, Andy
2003-01-01
The assessment of the publication of scientific works is a hard challenge when it is necessary to classify a curriculum vitae or even to verify the performance of an institution, such as a medical school, a postgraduate program or a research department. Most of time, the evaluation is based on personal feelings and experience, without established standard pattern. To present a guideline to evaluate the publications of scientific papers, without foreign influence. The guideline to assess the value of each publication is based on the multiplication of three factors. The first factor is the value of the author corresponding to his place among the authors in the authorship of the work. The second factor is the classification of the type of publication. Finally, the product of these two factors is multiplied by ten times the "impact factor" of the journal. When the "impact factor" is zero, 0.1 should substitute it. This method has been used by us since 1994, with good results and without any problem related to the judgment. This criterion prevents subjective interference. Conflicts of interest are avoided when clearly presented from the beginning of the judgment process.
Yoshihara, Hiroyuki
2014-07-01
Numerous surgical procedures and instrumentation techniques for lumbosacral fusion (LSF) have been developed. This is probably because of its high mechanical demand and unique anatomy. Surgical options include anterior column support (ACS) and posterior stabilization procedures. Biomechanical studies have been performed to verify the stability of those options. The options have their own advantage but also disadvantage aspects. This review article reports the surgical options for lumbosacral fusion, their biomechanical stability, advantages/disadvantages, and affecting factors in option selection. Review of literature. LSF has lots of options both for ACS and posterior stabilization procedures. Combination of posterior stabilization procedures is an option. Furthermore, combinations of ACS and posterior stabilization procedures are other options. It is difficult to make a recommendation or treatment algorithm of LSF from the current literature. However, it is important to know all aspects of the options and decision-making of surgical options for LSF needs to be tailored for each patient, considering factors such as biomechanical stress and osteoporosis.
In the eyes of the beholder: A non-self-report measure of workplace deviance.
Stewart, Susan M; Bing, Mark N; Davison, H Kristl; Woehr, David J; McIntyre, Michael D
2009-01-01
Because employees may be reluctant to admit to performing deviant acts, the authors of this study reexamined the commonly used self-report measure of workplace deviance developed by R. J. Bennett and S. L. Robinson (2000). Specifically, the self-report measure was modified into a non-self-report measure based on multiple other-reported assessments to address methodological concerns with self-reported information regarding deviant workplace behaviors. The authors assessed the psychometric properties of this new measure by first conducting an exploratory factor analysis, which indicated a 3-factor structure (production deviance, property deviance, and personal aggression). Subsequent confirmatory factor analysis on a different sample verified these findings. Taken together, the results suggest that the content and psychometric qualities of this non-self-report measure of workplace deviance closely represent S. L. Robinson and R. J. Bennett's (1995) original typology of workplace deviance. The potential usefulness of this measure in organizational studies is discussed. (PsycINFO Database Record (c) 2009 APA, all rights reserved).
Li, D D; Shi, W; Deng, X X
2003-12-01
Valencia sweet orange (Citrus sinensis (L.) Osbeck) calluses were used as explants to develop a new transformation system for citrus mediated by Agrobacterium tumefaciens. Factors affecting Agrobacterium-mediated transformation efficiency included mode of pre-cultivation, temperature of cocultivation and presence of acetosyringone (AS). The highest transformation efficiency was obtained with a 4-day pre-cultivation period in liquid medium. Transformation efficiency was higher when cocultivation was performed for 3 days at 19 degrees C than at 23 or 28 degrees C. Almost no resistant callus was obtained if the cocultivation medium lacked AS. The transformation procedure yielded transgenic Valencia plants containing the pTA29-barnase gene, as verified by PCR amplification and confirmed by Southern blotting. Because male sterility is a common factor leading to seedlessness in citrus cultivars with parthenocarpic characteristics, production of seedless citrus genotypes by Agrobacterium-mediated genetic transformation is a promising alternative to conventional breeding methods.
Design and evaluation of a trilateral shared-control architecture for teleoperated training robots.
Shamaei, Kamran; Kim, Lawrence H; Okamura, Allison M
2015-08-01
Multilateral teleoperated robots can be used to train humans to perform complex tasks that require collaborative interaction and expert supervision, such as laparoscopic surgical procedures. In this paper, we explain the design and performance evaluation of a shared-control architecture that can be used in trilateral teleoperated training robots. The architecture includes dominance and observation factors inspired by the determinants of motor learning in humans, including observational practice, focus of attention, feedback and augmented feedback, and self-controlled practice. Toward the validation of such an architecture, we (1) verify the stability of a trilateral system by applying Llewellyn's criterion on a two-port equivalent architecture, and (2) demonstrate that system transparency remains generally invariant across relevant observation factors and movement frequencies. In a preliminary experimental study, a dyad of two human users (one novice, one expert) collaborated on the control of a robot to follow a trajectory. The experiment showed that the framework can be used to modulate the efforts of the users and adjust the source and level of haptic feedback to the novice user.
Robust finger vein ROI localization based on flexible segmentation.
Lu, Yu; Xie, Shan Juan; Yoon, Sook; Yang, Jucheng; Park, Dong Sun
2013-10-24
Finger veins have been proved to be an effective biometric for personal identification in the recent years. However, finger vein images are easily affected by influences such as image translation, orientation, scale, scattering, finger structure, complicated background, uneven illumination, and collection posture. All these factors may contribute to inaccurate region of interest (ROI) definition, and so degrade the performance of finger vein identification system. To improve this problem, in this paper, we propose a finger vein ROI localization method that has high effectiveness and robustness against the above factors. The proposed method consists of a set of steps to localize ROIs accurately, namely segmentation, orientation correction, and ROI detection. Accurate finger region segmentation and correct calculated orientation can support each other to produce higher accuracy in localizing ROIs. Extensive experiments have been performed on the finger vein image database, MMCBNU_6000, to verify the robustness of the proposed method. The proposed method shows the segmentation accuracy of 100%. Furthermore, the average processing time of the proposed method is 22 ms for an acquired image, which satisfies the criterion of a real-time finger vein identification system.
A PDMS Device Coupled with Culture Dish for In Vitro Cell Migration Assay.
Lv, Xiaoqing; Geng, Zhaoxin; Fan, Zhiyuan; Wang, Shicai; Pei, WeiHua; Chen, Hongda
2018-04-30
Cell migration and invasion are important factors during tumor progression and metastasis. Wound-healing assay and the Boyden chamber assay are efficient tools to investigate tumor development because both of them could be applied to measure cell migration rate. Therefore, a simple and integrated polydimethylsiloxane (PDMS) device was developed for cell migration assay, which could perform quantitative evaluation of cell migration behaviors, especially for the wound-healing assay. The integrated device was composed of three units, which included cell culture dish, PDMS chamber, and wound generation mold. The PDMS chamber was integrated with cell culture chamber and could perform six experiments under different conditions of stimuli simultaneously. To verify the function of this device, it was utilized to explore the tumor cell migration behaviors under different concentrations of fetal bovine serum (FBS) and transforming growth factor (TGF-β) at different time points. This device has the unique capability to create the "wound" area in parallel during cell migration assay and provides a simple and efficient platform for investigating cell migration assay in biomedical application.
Gomes, Lara Elena; Loss, Jefferson Fagundes
2015-01-01
The understanding of swimming propulsion is a key factor in the improvement of performance in this sport. Propulsive forces have been quantified under steady conditions since the 1970s, but actual swimming involves unsteady conditions. Thus, the purpose of the present article was to review the effects of unsteady conditions on swimming propulsion based on studies that have compared steady and unsteady conditions while exploring their methods, their limitations and their results, as well as encouraging new studies based on the findings of this systematic review. A multiple database search was performed, and only those studies that met all eligibility criteria were included. Six studies that compared steady and unsteady conditions using physical experiments or numerical simulations were selected. The selected studies verified the effects of one or more factors that characterise a condition as unsteady on the propulsive forces. Consequently, much research is necessary to understand the effect of each individual variable that characterises a condition as unsteady on swimming propulsion, as well as the effects of these variables as a whole on swimming propulsion.
Robust Finger Vein ROI Localization Based on Flexible Segmentation
Lu, Yu; Xie, Shan Juan; Yoon, Sook; Yang, Jucheng; Park, Dong Sun
2013-01-01
Finger veins have been proved to be an effective biometric for personal identification in the recent years. However, finger vein images are easily affected by influences such as image translation, orientation, scale, scattering, finger structure, complicated background, uneven illumination, and collection posture. All these factors may contribute to inaccurate region of interest (ROI) definition, and so degrade the performance of finger vein identification system. To improve this problem, in this paper, we propose a finger vein ROI localization method that has high effectiveness and robustness against the above factors. The proposed method consists of a set of steps to localize ROIs accurately, namely segmentation, orientation correction, and ROI detection. Accurate finger region segmentation and correct calculated orientation can support each other to produce higher accuracy in localizing ROIs. Extensive experiments have been performed on the finger vein image database, MMCBNU_6000, to verify the robustness of the proposed method. The proposed method shows the segmentation accuracy of 100%. Furthermore, the average processing time of the proposed method is 22 ms for an acquired image, which satisfies the criterion of a real-time finger vein identification system. PMID:24284769
NASA Astrophysics Data System (ADS)
Ye, Long; Hu, Huawei; Ghasemi, Masoud; Wang, Tonghui; Collins, Brian A.; Kim, Joo-Hyun; Jiang, Kui; Carpenter, Joshua H.; Li, Hong; Li, Zhengke; McAfee, Terry; Zhao, Jingbo; Chen, Xiankai; Lai, Joshua Lin Yuk; Ma, Tingxuan; Bredas, Jean-Luc; Yan, He; Ade, Harald
2018-03-01
Although it is known that molecular interactions govern morphology formation and purity of mixed domains of conjugated polymer donors and small-molecule acceptors, and thus largely control the achievable performance of organic solar cells, quantifying interaction-function relations has remained elusive. Here, we first determine the temperature-dependent effective amorphous-amorphous interaction parameter, χaa(T), by mapping out the phase diagram of a model amorphous polymer:fullerene material system. We then establish a quantitative `constant-kink-saturation' relation between χaa and the fill factor in organic solar cells that is verified in detail in a model system and delineated across numerous high- and low-performing materials systems, including fullerene and non-fullerene acceptors. Our experimental and computational data reveal that a high fill factor is obtained only when χaa is large enough to lead to strong phase separation. Our work outlines a basis for using various miscibility tests and future simulation methods that will significantly reduce or eliminate trial-and-error approaches to material synthesis and device fabrication of functional semiconducting blends and organic blends in general.
Tailoring the Interfacial Chemical Interaction for High-Efficiency Perovskite Solar Cells.
Zuo, Lijian; Chen, Qi; De Marco, Nicholas; Hsieh, Yao-Tsung; Chen, Huajun; Sun, Pengyu; Chang, Sheng-Yung; Zhao, Hongxiang; Dong, Shiqi; Yang, Yang
2017-01-11
The ionic nature of perovskite photovoltaic materials makes it easy to form various chemical interactions with different functional groups. Here, we demonstrate that interfacial chemical interactions are a critical factor in determining the optoelectronic properties of perovskite solar cells. By depositing different self-assembled monolayers (SAMs), we introduce different functional groups onto the SnO 2 surface to form various chemical interactions with the perovskite layer. It is observed that the perovskite solar cell device performance shows an opposite trend to that of the energy level alignment theory, which shows that chemical interactions are the predominant factor governing the interfacial optoelectronic properties. Further analysis verifies that proper interfacial interactions can significantly reduce trap state density and facilitate the interfacial charge transfer. Through use of the 4-pyridinecarboxylic acid SAM, the resulting perovskite solar cell exhibits striking improvements to the reach the highest efficiency of 18.8%, which constitutes an ∼10% enhancement compared to those without SAMs. Our work highlights the importance of chemical interactions at perovskite/electrode interfaces and paves the way for further optimizing performances of perovskite solar cells.
Mobile Phone Use in a Developing Country: A Malaysian Empirical Study
ERIC Educational Resources Information Center
Yeow, Paul H. P.; Yen Yuen, Yee; Connolly, Regina
2008-01-01
This study examined the factors that influence consumer satisfaction with mobile telephone use in Malaysia. The validity of the study's constructs, criterion, and content was confirmed. Construct validity was verified through the factor analysis with a total variance of 73.72 percent explained by all six independent factors. Content validity was…
DOT National Transportation Integrated Search
2014-02-01
This report contains the results of a study describing the development of resistance factors for use : with the Kansas Department of Transportation (KDOT) Engineering News Record (ENR) formula for driven : piles. KDOT has verified driven pile resista...
Recognizing Disguised Faces: Human and Machine Evaluation
Dhamecha, Tejas Indulal; Singh, Richa; Vatsa, Mayank; Kumar, Ajay
2014-01-01
Face verification, though an easy task for humans, is a long-standing open research area. This is largely due to the challenging covariates, such as disguise and aging, which make it very hard to accurately verify the identity of a person. This paper investigates human and machine performance for recognizing/verifying disguised faces. Performance is also evaluated under familiarity and match/mismatch with the ethnicity of observers. The findings of this study are used to develop an automated algorithm to verify the faces presented under disguise variations. We use automatically localized feature descriptors which can identify disguised face patches and account for this information to achieve improved matching accuracy. The performance of the proposed algorithm is evaluated on the IIIT-Delhi Disguise database that contains images pertaining to 75 subjects with different kinds of disguise variations. The experiments suggest that the proposed algorithm can outperform a popular commercial system and evaluates them against humans in matching disguised face images. PMID:25029188
A graphics-card implementation of Monte-Carlo simulations for cosmic-ray transport
NASA Astrophysics Data System (ADS)
Tautz, R. C.
2016-05-01
A graphics card implementation of a test-particle simulation code is presented that is based on the CUDA extension of the C/C++ programming language. The original CPU version has been developed for the calculation of cosmic-ray diffusion coefficients in artificial Kolmogorov-type turbulence. In the new implementation, the magnetic turbulence generation, which is the most time-consuming part, is separated from the particle transport and is performed on a graphics card. In this article, the modification of the basic approach of integrating test particle trajectories to employ the SIMD (single instruction, multiple data) model is presented and verified. The efficiency of the new code is tested and several language-specific accelerating factors are discussed. For the example of isotropic magnetostatic turbulence, sample results are shown and a comparison to the results of the CPU implementation is performed.
NASA Astrophysics Data System (ADS)
Kai, Takaaki; Tanaka, Yuji; Kaneda, Hirotoshi; Kobayashi, Daichi; Tanaka, Akio
Recently, doubly fed induction generator (DFIG) and synchronous generator are mostly applied for wind power generation, and variable speed control and power factor control are executed for high efficiently for wind energy capture and high quality for power system voltage. In variable speed control, a wind speed or a generator speed is used for maximum power point tracking. However, performances of a wind generation power fluctuation due to wind speed variation have not yet investigated for those controls. The authors discuss power smoothing by those controls for the DFIG inter-connected to 6.6kV distribution line. The performances are verified using power system simulation software PSCAD/EMTDC for actual wind speed data and are examined from an approximate equation of wind generation power fluctuation for wind speed variation.
NASA Technical Reports Server (NTRS)
Dejesusparada, N. (Principal Investigator); Sausen, T. M.
1981-01-01
The use of LANDSAT multispectral ban scanner imagery to verify the relationship between the behavior of the Tres Marias reservoir and the dynamics of the Sao Francisco River supply basin is described. The dispersion of suspended sediments and their concentration in the surface layers of the water are considered. A five year survey of the region during both dry and rainy seasons was performed. The drainage network was analyzed based on the patterns of dessication, water rises and soil use in the supply basin. Surface layers of the reservoir were tabulated as a function of the levels of gray in the imagery. In situ observations of water depth and reflectance were performed. Ground truth and LANDSAT data were correlated to determine the factors affecting the dynamics of the supply basin.
Tsai, Kuo-Ming; Wang, He-Yi
2014-08-20
This study focuses on injection molding process window determination for obtaining optimal imaging optical properties, astigmatism, coma, and spherical aberration using plastic lenses. The Taguchi experimental method was first used to identify the optimized combination of parameters and significant factors affecting the imaging optical properties of the lens. Full factorial experiments were then implemented based on the significant factors to build the response surface models. The injection molding process windows for lenses with optimized optical properties were determined based on the surface models, and confirmation experiments were performed to verify their validity. The results indicated that the significant factors affecting the optical properties of lenses are mold temperature, melt temperature, and cooling time. According to experimental data for the significant factors, the oblique ovals for different optical properties on the injection molding process windows based on melt temperature and cooling time can be obtained using the curve fitting approach. The confirmation experiments revealed that the average errors for astigmatism, coma, and spherical aberration are 3.44%, 5.62%, and 5.69%, respectively. The results indicated that the process windows proposed are highly reliable.
NASA Astrophysics Data System (ADS)
Rout, Biswaranjan; Dash, R. R.; Dhupal, D.
2018-02-01
In this work a typical planning of movement of limbs and torso of the worker to be well design to reduce fatigue and energy of the worker. A simulation model is generated to suit the procedure and comply with the constraints in the workspace. It requires verifying the capability of human postures and movements in different working conditions for the evaluation of effectiveness of the new design. In this article a simple human performance measure is introduce that enable the mathematical model for evaluation of a cost function. The basic scheme is to evaluate the performance in the form of several cost factors using AI techniques. Here two main cost factors taken in to consideration are discomfort factor and effort factor in limb movements. Discomfort factor measures the level of discomfort from the most neutral position of a given limb to the position of the corresponding limb after movement and effort factor is a measure of the displacement of the corresponding limbs from the original position. The basic aim is to optimize the movement of the limbs with the above mentioned cost functions. The effectiveness of the procedure is tested with an example of working procedure of workers used for stacking of fly ash bricks in a local fly ash bricks manufacturing unit. The objective is to find out the optimised movement of the limbs to reduce discomfort level and effort required of workers. The effectiveness of the procedure in this case study illustrated with the obtained results.
Borschmann, Rohan; Young, Jesse T.; Moran, Paul; Spittal, Matthew J.; Snow, Kathryn; Mok, Katherine; Kinner, Stuart A.
2017-01-01
Background: Self-harm is prevalent in prison populations and is a well-established risk factor for suicide. Researchers typically rely on self-report to measure self-harm, yet the accuracy and predictive value of self-report in prison populations is unclear. Using a large, representative sample of incarcerated men and women, we aimed to examine the level of agreement between self-reported self-harm history and historical medical records, and investigate the association between self-harm history and medically verified self-harm after release from prison. Methods: During confidential interviews with 1315 adults conducted within 6 weeks of expected release from 1 of 7 prisons in Queensland, Australia, participants were asked about the occurrence of lifetime self-harm. Responses were compared with prison medical records and linked both retrospectively and prospectively with ambulance, emergency department and hospital records to identify instances of medically verified self-harm. Follow-up interviews roughly 1, 3 and 6 months after release covered the same domains assessed in the baseline interview as well as self-reported criminal activity and contact with health care, social and criminal justice services since release. Results: Agreement between self-reported and medically verified history of self-harm was poor, with 64 (37.6%) of 170 participants with a history of medically verified self-harm disclosing a history of self-harm at baseline. Participants with a medically verified history of self-harm were more likely than other participants to self-harm during the follow-up period. Compared to the unconfirmed-negative group, the true-positive (adjusted hazard ratio [HR] 6.2 [95% confidence interval (CI) 3.3-10.4]), false-negative (adjusted HR 4.0 [95% CI 2.2-6.7]) and unconfirmed-positive (adjusted HR 2.2 [95% CI 1.2-3.9]) groups were at increased risk for self-harm after release from prison. Interpretation: Self-reported history of self-harm should not be considered a sensitive indicator of prior self-harm or of future self-harm risk in incarcerated adults. To identify those who should be targeted for preventive strategies, triangulation of data from multiple verifiable sources should be performed whenever possible. PMID:28893844
Code of Federal Regulations, 2010 CFR
2010-07-01
... which you sample and record gas-analyzer concentrations. (b) Measurement principles. This test verifies... appropriate frequency to prevent loss of information. This test also verifies that the measurement system... instructions. Adjust the measurement system as needed to optimize performance. Run this verification with the...
NASA Astrophysics Data System (ADS)
Yosri, M. H.; Muhamad, P.; Ismail, M. A.; Yatim, N. H. M.
2018-01-01
Dust and fiber have been identified among the highest contributor for the defect in automotive painting line with range from 40% to 50% of total defect breakdown. Eventually, those defects will effect on both visual appearance and also the performance of the parts. In addition, the significance of controlling dust in an assembly line is crucial in order to maintain the quality of the product, part performance yield and effect on workers’ health [1]. By considering the principle and technology applied in electronic clean room technology, the ionizer have been introduce to control dust contamination in automotive painting line. The first auto maker industry whom found the effectiveness of the clean room application to reduce the defect and production line downtime was Chrysler [2]. By doing so, it’s allowed the transmission plant to offer 50 000 mile guarantee on the transmission systems. The main objective of this research is to verify the effectiveness of ionizer device in order to reduce the rejection contribute by dust and fiber particle in the automotive painting line. Towards the main objective, a few sub areas will be explored, as a supporting factor to ensure the result gain from this study is solid and constructive. The experiment start by verifying the electrostatic value of the raw material (substrate) before and after the ionizer treatment. From here the correlation of the electrostatic value generated by the raw material that effect to production pass rate can be explored. At the meantime, the performance of the production pass rate after the ionizer treatment which related to the painted surface area can be determined.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Finch, Robert J.; Smartt, Heidi A.; Haddal, Risa
Once a geological repository has begun operations, the encapsulation and disposal of spent fuel will be performed as a continuous, industrial-scale series of processes, during which time safeguards seals will be applied to transportation casks before shipment from an encapsulation plant, and then verified and removed following receipt at the repository. These operations will occur approximately daily during several decades of Sweden's repository operation; however, requiring safeguards inspectors to perform the application, verification, and removal of every seal would be an onerous burden on International Atomic Energy Agency's (IAEA's) resources. Current IAEA practice includes allowing operators to either apply sealsmore » or remove them, but not both, so the daily task of either applying or verifying and removing would still require continuous presence of IAEA inspectors at one site at least. Of special importance is the inability to re-verify cask or canisters from which seals have been removed and the canisters emplaced underground. Successfully designing seals that can be applied, verified and removed by an operator with IAEA approval could impact more than repository shipments, but other applications as well, potentially reducing inspector burdens for a wide range of such duties.« less
Lin, Chung-Yin; Hsieh, Han-Yi; Chen, Chiung-Mei; Wu, Shang-Rung; Tsai, Chih-Hung; Huang, Chiung-Yin; Hua, Mu-Yi; Wei, Kuo-Chen; Yeh, Chih-Kuang; Liu, Hao-Li
2016-08-10
Focused ultrasound (FUS)-induced with microbubbles (MBs) is a promising technique for noninvasive opening of the blood-brain barrier (BBB) to allow targeted delivery of therapeutic substances into the brain and thus the noninvasive delivery of gene vectors for CNS treatment. We have previously demonstrated that a separated gene-carrying liposome and MBs administration plus FUS exposure can deliver genes into the brain, with the successful expression of the reporter gene and glial cell line-derived neurotrophic factor (GDNF) gene. In this study, we further modify the delivery system by conjugating gene-carrying liposomes with MBs to improve the GDNF gene-delivery efficiency, and to verify the possibility of using this system to perform treatment in the 1-Methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP)-induced animal disease model. FUS-BBB opening was verified by contrast-enhanced MRI, and GFP gene expression was verified via in vivo imaging system (IVIS). Western blots as well as enzyme-linked immunosorbent assay (ELISA) were conducted to measure protein expression, and immunohistochemistry (IHC) was conducted to test the Tyrosine hydroxylase (TH)-neuron distribution. Dopamine (DA) and its metabolites as well as dopamine active transporter (DAT) were quantitatively analyzed to show dopaminergic neuronal dopamine secretion/activity/metabolism. Motor performance was evaluated by rotarod test weekly. Results demonstrated that the LpDNA-MBs (gene-liposome-MBs) complexes successfully serve as gene carrier and BBB-opening catalyst, and outperformed the separated LpDNA/MBs administration both in terms of gene delivery and expression. TH-positive IHC and measurement of DA and its metabolites DOPAC and HVA confirmed improved neuronal function, and the proposed system also provided the best neuroprotective effect to retard the progression of motor-related behavioral abnormalities. Immunoblotting and histological staining further confirmed the expression of reporter genes in neuronal cells. This study suggests that FUS exposures with the administration of LpDNA-MBs complexes synergistically can serve as an effective gene therapy strategy for MPTP-animal treatment, and may have potential for further application to perform gene therapy for neurodegenerative disease. Copyright © 2016 Elsevier B.V. All rights reserved.
Centaur Standard Shroud (CSS) Heated Altitude Jettison Tests
NASA Technical Reports Server (NTRS)
1975-01-01
Altitude jettison tests, at a pressure of 20 torr (0.39 psia), were performed on the Centaur Standard Shroud (CSS) in a 100-foot diameter vacuum chamber. These jettison tests were part of a series of flight qualification tests which were performed on the new CSS system in preparation for the Helios and Viking missions. The first two tests subjected the CSS to a thermal cycle which simulated aerodynamic heating during ascent flight and the third test was performed at altitude pressure and in ambient temperature conditions. The purpose of the ambient temperature test was to provide base line data by which the separate machanical and thermal factors that influence jettison performance could be evaluated individually. The CSS was successfully jettisoned in each of the three tests. Also, thermal, stress, and structural deflection data were obtained which verified the analytical predictions of CSS response to flight environmental conditions and performance during jettison. In addition, much important information was obtained on critical CSS-to-payload clearance losses due to shell motions prior to and during jettison. The effectiveness of the separation system was successfully demonstrated at maximum flight temperatures.
Optimum processing of mammographic film.
Sprawls, P; Kitts, E L
1996-03-01
Underprocessing of mammographic film can result in reduced contrast and visibility of breast structures and an unnecessary increase in radiation dose to the patient. Underprocessing can be caused by physical factors (low developer temperature, inadequate development time, insufficient developer agitation) or chemical factors (developer not optimized for film type; overdiluted, underreplenished, contaminated, or frequently changed developer). Conventional quality control programs are designed to produce consistent processing but do not address the issue of optimum processing. Optimum processing is defined as the level of processing that produces the film performance characteristics (contrast and sensitivity) specified by the film manufacturer. Optimum processing of mammographic film can be achieved by following a two-step protocol. The first step is to set up the processing conditions according to recommendations from the film and developer chemistry manufacturers. The second step is to verify the processing results by comparing them with sensitometric data provided by the film manufacturer.
NASA Astrophysics Data System (ADS)
Khoa Nguyen, Trieu; Lee, Dong-Weon; Lee, Bong-Kee
2017-06-01
In this study, a numerical investigation of microcantilever sensors for detecting the contractile behavior of cardiomyocytes (CMs) was performed. Recently, a novel surface-patterned perforated SU-8 microcantilever sensor has been developed for the preliminary screening of cardiac toxicity. From the contractile motion of the CMs cultured on the microcantilever surface, a macroscopic bending of the microcantilever was obtained, which is considered to reflect a physiological change. As a continuation of the previous research, a novel numerical method based on a surface traction model was proposed and verified to further understand the bending behavior of the microcantilevers. Effects of various factors, including surface traction magnitude, focal area of CMs, and stiffness of microcantilever, on the bending displacement were investigated. From static and transient analyses, the focal area was found to be the most crucial factor. In addition, the current result can provide a design guideline for various micromechanical devices based on the same principle.
Hassan, Hafeez Ul; Nielsen, Kristian; Aasmul, Soren; Bang, Ole
2015-01-01
We demonstrate that the light excitation and capturing efficiency of fluorescence based fiber-optical sensors can be significantly increased by using a CPC (Compound Parabolic Concentrator) tip instead of the standard plane-cut tip. We use Zemax modelling to find the optimum CPC tip profile and fiber length of a polymer optical fiber diabetes sensor for continuous monitoring of glucose levels. We experimentally verify the improved performance of the CPC tipped sensor and the predicted production tolerances. Due to physical size requirements when the sensor has to be inserted into the body a non-optimal fiber length of 35 mm is chosen. For this length an average improvement in efficiency of a factor of 1.7 is experimentally demonstrated and critically compared to the predicted ideal factor of 3 in terms of parameters that should be improved through production optimization. PMID:26713213
History of childhood trauma as risk factors to suicide risk in major depression.
Dias de Mattos Souza, Luciano; Lopez Molina, Mariane; Azevedo da Silva, Ricardo; Jansen, Karen
2016-12-30
The aim of this study was to compare childhood trauma scores domains between Major Depressive Disorder (MDD) patients with and without suicide risk. This is cross-sectional study including a clinical sample of adults (18-60 years) diagnosed with MDD through the Mini International Neuropsychiatric Interview Plus version (MINI Plus). The Childhood Trauma Questionnaire (CTQ) was also used to verify types of trauma scores: abuse (emotional, physical, and sexual) and neglect (emotional and physical). Adjusted analysis was performed by linear regression. The sample was composed to 473 patients, suicide risk was observed in 16.3% of them. Suicide risk was independently associated with emotional abuse and neglect and sexual abuse, but not with physical abuse and neglect. Different domains of childhood trauma are associated with suicide risk in MDD population and emotional trauma should be considered a risk factor for suicide risk in MDD patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Hassan, Hafeez Ul; Nielsen, Kristian; Aasmul, Soren; Bang, Ole
2015-12-01
We demonstrate that the light excitation and capturing efficiency of fluorescence based fiber-optical sensors can be significantly increased by using a CPC (Compound Parabolic Concentrator) tip instead of the standard plane-cut tip. We use Zemax modelling to find the optimum CPC tip profile and fiber length of a polymer optical fiber diabetes sensor for continuous monitoring of glucose levels. We experimentally verify the improved performance of the CPC tipped sensor and the predicted production tolerances. Due to physical size requirements when the sensor has to be inserted into the body a non-optimal fiber length of 35 mm is chosen. For this length an average improvement in efficiency of a factor of 1.7 is experimentally demonstrated and critically compared to the predicted ideal factor of 3 in terms of parameters that should be improved through production optimization.
Unique Factorization in Cyclotomic Integers of Degree Seven
ERIC Educational Resources Information Center
Duckworth, W. Ethan
2008-01-01
This article provides a survey of some basic results in algebraic number theory and applies this material to prove that the cyclotomic integers generated by a seventh root of unity are a unique factorization domain. Part of the proof uses the computer algebra system Maple to find and verify factorizations. The proofs use a combination of historic…
Near-field testing of the 15-meter hoop-column antenna
NASA Technical Reports Server (NTRS)
Schroeder, Lyle C.; Adams, Richard R.; Bailey, M. C.; Belvin, W. Keith; Butler, David H.; Campbell, Thomas G.
1989-01-01
A 15-m-diameter antenna was tested to verify that dimensional tolerances for acceptable performance could be achieved and to verify structural, electromagnetic, and mechanical performance predictions. This antenna utilized the hoop column structure, a gold plated molybdenum mesh reflector, and 96 control cables to adjust the reflector conformance with a paraboloid. The dimensional conformance of the antenna structure and surface was measured with metric camera and theodolites. Near field pattern data were used to assess the electromagnetic performance at five frequencies from 2.225 to 11.6 GHz. The reflector surface was adjusted to greatly improve electromagnetic performance with a finite element model and the surface measurements. Measurement results show that antenna surface figure and adjustments and electromagnetic patterns agree well with predictions.
Assessment of composite motif discovery methods.
Klepper, Kjetil; Sandve, Geir K; Abul, Osman; Johansen, Jostein; Drablos, Finn
2008-02-26
Computational discovery of regulatory elements is an important area of bioinformatics research and more than a hundred motif discovery methods have been published. Traditionally, most of these methods have addressed the problem of single motif discovery - discovering binding motifs for individual transcription factors. In higher organisms, however, transcription factors usually act in combination with nearby bound factors to induce specific regulatory behaviours. Hence, recent focus has shifted from single motifs to the discovery of sets of motifs bound by multiple cooperating transcription factors, so called composite motifs or cis-regulatory modules. Given the large number and diversity of methods available, independent assessment of methods becomes important. Although there have been several benchmark studies of single motif discovery, no similar studies have previously been conducted concerning composite motif discovery. We have developed a benchmarking framework for composite motif discovery and used it to evaluate the performance of eight published module discovery tools. Benchmark datasets were constructed based on real genomic sequences containing experimentally verified regulatory modules, and the module discovery programs were asked to predict both the locations of these modules and to specify the single motifs involved. To aid the programs in their search, we provided position weight matrices corresponding to the binding motifs of the transcription factors involved. In addition, selections of decoy matrices were mixed with the genuine matrices on one dataset to test the response of programs to varying levels of noise. Although some of the methods tested tended to score somewhat better than others overall, there were still large variations between individual datasets and no single method performed consistently better than the rest in all situations. The variation in performance on individual datasets also shows that the new benchmark datasets represents a suitable variety of challenges to most methods for module discovery.
NASA Technical Reports Server (NTRS)
Pace, R. E., Jr.; Craft, H. G., Jr.
1977-01-01
NASA has issued payload flight assignments for the first three Spacelab missions. The first two of these missions will have dual objectives, that of verifying Spacelab system performance and accomplishing meaningful space research. The first of these missions will be a joint NASA and ESA mission with a multidisciplinary payload. The second mission will verify a different Spacelab configuration while addressing the scientific disciplines of astrophysics. The third assigned mission will concentrate on utilizing the capabilities of Spacelab to perform meaningful experiments in space applications, primarily space processing. The paper describes these missions with their objectives, planned configuration and accommodation.
NASA Technical Reports Server (NTRS)
Silva-Martinez, Jackelynne; Ellenberger, Richard; Dory, Jonathan
2017-01-01
This project aims to identify poor human factors design decisions that led to error-prone systems, or did not facilitate the flight crew making the right choices; and to verify that NASA is effectively preventing similar incidents from occurring again. This analysis was performed by reviewing significant incidents and close calls in human spaceflight identified by the NASA Johnson Space Center Safety and Mission Assurance Flight Safety Office. The review of incidents shows whether the identified human errors were due to the operational phase (flight crew and ground control) or if they initiated at the design phase (includes manufacturing and test). This classification was performed with the aid of the NASA Human Systems Integration domains. This in-depth analysis resulted in a tool that helps with the human factors classification of significant incidents and close calls in human spaceflight, which can be used to identify human errors at the operational level, and how they were or should be minimized. Current governing documents on human systems integration for both government and commercial crew were reviewed to see if current requirements, processes, training, and standard operating procedures protect the crew and ground control against these issues occurring in the future. Based on the findings, recommendations to target those areas are provided.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kolhoff, Arend J., E-mail: akolhoff@eia.nl; Runhaar, Hens A.C., E-mail: H.A.C.Runhaar@uu.nl; Forest and Nature Conservation Policy Group, Wageningen University and Research Centre, Wageningen
In this paper, we aim to better understand the factors that contribute to the substantive performance of EIA systems in low and middle income countries. Substantive performance is defined as the extent to which the EIA process contributes to the EIA objectives for the long term, namely environmental protection or, even more ambitious, sustainable development. We have therefore developed a conceptual model in which we focus on the key actors in the EIA system, the proponent and the EIA authority and their level of ownership as a key capacity to measure their performance, and we distinguish procedural performance and somemore » contextual factors. This conceptual model is then verified and refined for the EIA phase and the EIA follow-up phase (permitting, monitoring and enforcement) by means of 12 case studies from Ghana (four cases) and Georgia (eight cases), both lower–middle income countries. We observe that in most cases the level of substantive performance increases during the EIA phase but drops during the EIA follow-up phase, and as a result only five out of 12 operational cases are in compliance with permit conditions or national environmental standards. We conclude, firstly that ownership of the proponent is the most important factor explaining the level of substantive performance; the higher the proponent's level of ownership the higher the level of substantive performance. The influence of the EIA authority on substantive performance is limited. Secondly, the influence of procedural performance on substantive performance seems less important than expected in the EIA phase but more important during the EIA follow-up phase. In order to improve substantive performance we learned two lessons. Firstly, increasing the proponent's level of ownership seems obvious, but direct change is probably difficult. However, where international finance institutes are involved they can increase ownership. Despite the limited influence of the EIA authority, a proactive strategy of, for example, working together with international finance institutes has a slightly larger influence than a reactive strategy. - Highlights: • Ownership of the proponent is the most important factor explaining the level of substantive performance. • The influence of the EIA authority on substantive performance is limited. • The influence of procedural performance on substantive performance seems less important than expected in the EIA phase but more important during the EIA follow-up phase.« less
Type Theory, Computation and Interactive Theorem Proving
2015-09-01
postdoc Cody Roux, to develop new methods of verifying real-valued inequalities automatically. They developed a prototype implementation in Python [8] (an...he has developed new heuristic, geometric methods of verifying real-valued inequalities. A python -based implementation has performed surprisingly...express complex mathematical and computational assertions. In this project, Avigad and Harper developed type-theoretic algorithms and formalisms that
Verification of reliability and validity of a Japanese version of the Rathus Assertiveness Schedule.
Suzuki, Eiko; Kanoya, Yuka; Katsuki, Takeshi; Sato, Chifumi
2007-07-01
To verify the reliability and validity of a Japanese version of the Rathus Assertiveness Schedule in novice nurses to contribute to nursing management. An adequate scale is needed to measure the assertiveness and the effect of assertion training for Japanese nurses and to compare them with those in other countries. Rathus Assertiveness Schedule was adapted to Japanese with back-translation and its validity was examined in 989 novice nurses. The Japanese version showed a high coefficient of reliability in a split-half reliability test (r=0.76; P<0.01). The coefficient of reliability of Cronbach's alpha was high (r=0.84; P<0.01) indicating high internal consistency. The similarity with the concept of stress coping was shown. We extracted eight principal factors using factor analysis with varimax rotation. Elements of these factors were similar to those of the original Rathus Assertiveness Schedule. The Japanese version of Rathus Assertiveness Schedule was verified.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seol, Daehee; Park, Seongjae; Varenyk, Olexandr V.
Hysteresis loop analysis via piezoresponse force microscopy (PFM) is typically performed to probe the existence of ferroelectricity at the nanoscale. But, such an approach is rather complex in accurately determining the pure contribution of ferroelectricity to the PFM. We suggest a facile method to discriminate the ferroelectric effect from the electromechanical (EM) response through the use of frequency dependent ac amplitude sweep with combination of hysteresis loops in PFM. This combined study through experimental and theoretical approaches verifies that this method can be used as a new tool to differentiate the ferroelectric effect from the other factors that contribute tomore » the EM response.« less
Sequeira, Carlos Alberto da Cruz; Barbosa, Elsa Natalina Mendes; Nogueira, Maria José Carvalho; Sampaio, Francisco Miguel Correia
2017-10-01
Translate, adapt the language, and assess the psychometric properties of the Mental Vulnerability Questionnaire (MVQ) in a Portuguese population sample of young adults. A psychometric validation study was performed. The sample comprised 166 undergraduate students. Factor analysis was applied to extract three indicators. The MVQ showed divergent validity with the Positive Mental Health Questionnaire (p < .001) and convergent validity with the Mental Health Inventory including five items (p < .001). Reliability was verified through the assessment of internal consistency, evidencing positive outcomes (Cronbach's α = 0.81). The MVQ shows psychometric properties enabling its adaptation to clinical practice and research, essential to an effective screening of mental vulnerability. © 2016 Wiley Periodicals, Inc.
Seol, Daehee; Park, Seongjae; Varenyk, Olexandr V.; ...
2016-07-28
Hysteresis loop analysis via piezoresponse force microscopy (PFM) is typically performed to probe the existence of ferroelectricity at the nanoscale. But, such an approach is rather complex in accurately determining the pure contribution of ferroelectricity to the PFM. We suggest a facile method to discriminate the ferroelectric effect from the electromechanical (EM) response through the use of frequency dependent ac amplitude sweep with combination of hysteresis loops in PFM. This combined study through experimental and theoretical approaches verifies that this method can be used as a new tool to differentiate the ferroelectric effect from the other factors that contribute tomore » the EM response.« less
NATURAL AND ANTHROPOGENIC FACTORS INFLUENCING FOOD WEB STRUCTURE IN GREAT LAKES COASTAL WETLANDS
We are investigating factors governing the biological organization of Great Lakes coastal wetlands. Food web analyses using stable isotope techniques verify the role of algae as an energetic foundation, and also suggest that fundamental changes occur as a result of anthropogenic ...
The Houdini Transformation: True, but Illusory
ERIC Educational Resources Information Center
Bentler, Peter M.; Molenaar, Peter C. M.
2012-01-01
Molenaar (2003, 2011) showed that a common factor model could be transformed into an equivalent model without factors, involving only observed variables and residual errors. He called this invertible transformation the Houdini transformation. His derivation involved concepts from time series and state space theory. This article verifies the…
Intensity-enhanced MART for tomographic PIV
NASA Astrophysics Data System (ADS)
Wang, HongPing; Gao, Qi; Wei, RunJie; Wang, JinJun
2016-05-01
A novel technique to shrink the elongated particles and suppress the ghost particles in particle reconstruction of tomographic particle image velocimetry is presented. This method, named as intensity-enhanced multiplicative algebraic reconstruction technique (IntE-MART), utilizes an inverse diffusion function and an intensity suppressing factor to improve the quality of particle reconstruction and consequently the precision of velocimetry. A numerical assessment about vortex ring motion with and without image noise is performed to evaluate the new algorithm in terms of reconstruction, particle elongation and velocimetry. The simulation is performed at seven different seeding densities. The comparison of spatial filter MART and IntE-MART on the probability density function of particle peak intensity suggests that one of the local minima of the distribution can be used to separate the ghosts and actual particles. Thus, ghost removal based on IntE-MART is also introduced. To verify the application of IntE-MART, a real plate turbulent boundary layer experiment is performed. The result indicates that ghost reduction can increase the accuracy of RMS of velocity field.
Nondestructive Examination for Nuclear Power Plant Cable Aging Management Programs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glass, Samuel W.; Fifield, Leonard S.
2016-01-01
Degradation of the cable jacket, electrical insulation, and other cable components of installed cables within nuclear power plants (NPPs) is known to occur as a function of age, temperature, radiation, and other environmental factors. System tests verify cable function under normal loads; however, the concern is over cable performance under exceptional loads associated with design-basis events (DBEs). The cable’s ability to perform safely over the initial 40 year planned and licensed life has generally been demonstrated and there have been very few age-related cable failures. With greater than 1000 km of power, control, instrumentation, and other cables typically found inmore » an NPP, replacing all the cables would be a severe cost burden. Justification for life extension to 60 and 80 years requires a cable aging management program (AMP) to justify cable performance under normal operation as well as accident conditions. This paper addresses various NDE technologies that constitute the essence of an acceptable aging management program.« less
Numerical Investigation of the Effect of Radial Lip Seal Geometry on Sealing Performance
NASA Astrophysics Data System (ADS)
Tok, G.; Parlar, Z.; Temiz, V.
2018-01-01
Sealing elements are often needed in industry and especially in machine design. With the change and development of machine technology from day to day, sealing elements show continuous development and change in parallel with these developments. Many factors influence the performance of the sealing elements such as shaft surface roughness, radial force, lip geometry etc. In addition, the radial lip seals must have a certain pre-load and interference in order to provide a good sealing. This also affects the friction torque. Researchers are developing new seal designs to reduce friction losses in mechanical systems. In the presented study, the effect of the lip seal geometry on sealing performance will be examined numerically. The numerical model created for this purpose will be verified with experimental data firstly. In the numerical model, shaft and seal will be modeled as hyper-elastic in 2D and 3D. NBR (Nitrile Butadiene Rubber) as seal material will be analyzed for the rotating shaft state at constant speed by applying a uniform radial force.
NASA Astrophysics Data System (ADS)
Alagba, Tonye J.
Oil and gas drilling projects are the primary means by which oil companies recover large volumes of commercially available hydrocarbons from deep reservoirs. These types of projects are complex in nature, involving management of multiple stakeholder interfaces, multidisciplinary personnel, complex contractor relationships, and turbulent environmental and market conditions, necessitating the application of proven project management best practices and critical success factors (CSFs) to achieve success. Although there is some practitioner oriented literature on project management CSFs for drilling projects, none of these is based on empirical evidence, from research. In addition, the literature has reported alarming rates of oil and gas drilling project failure, which is attributable not to technical factors, but to failure of project management. The aim of this quantitative correlational study therefore, was to discover an empirically verified list of project management CSFs, which consistent application leads to successful implementation of oil and gas drilling projects. The study collected survey data online, from a random sample of 127 oil and gas drilling personnel who were members of LinkedIn's online community "Drilling Supervisors, Managers, and Engineers". The results of the study indicated that 10 project management factors are individually related to project success of oil and gas drilling projects. These 10 CSFs are namely; Project mission, Top management support, Project schedule/plan, Client consultation, Personnel, Technical tasks, Client acceptance, Monitoring and feedback, Communication, and Troubleshooting. In addition, the study found that the relationships between the 10 CSFs and drilling project success is unaffected by participant and project demographics---role of project personnel, and project location. The significance of these findings are both practical, and theoretical. Practically, application of an empirically verified CSFs list to oil and gas drilling projects could help oil companies improve the performance of future drilling projects. Theoretically, the study's findings may help to bridge a gap in the project management CSFs literature, and add to the general project management body of knowledge.
NASA Astrophysics Data System (ADS)
Arellano, A. F., Jr.; Tang, W.
2017-12-01
Assimilating observational data of chemical constituents into a modeling system is a powerful approach in assessing changes in atmospheric composition and estimating associated emissions. However, the results of such chemical data assimilation (DA) experiments are largely subject to various key factors such as: a) a priori information, b) error specification and representation, and c) structural biases in the modeling system. Here we investigate the sensitivity of an ensemble-based data assimilation state and emission estimates to these key factors. We focus on investigating the assimilation performance of the Community Earth System Model (CESM)/CAM-Chem with the Data Assimilation Research Testbed (DART) in representing biomass burning plumes in the Amazonia during the 2008 fire season. We conduct the following ensemble DA MOPITT CO experiments: 1) use of monthly-average NCAR's FINN surface fire emissionss, 2) use of daily FINN surface fire emissions, 3) use of daily FINN emissions with climatological injection heights, and 4) use of perturbed FINN emission parameters to represent not only the uncertainties in combustion activity but also in combustion efficiency. We show key diagnostics of assimilation performance for these experiments and verify with available ground-based and aircraft-based measurements.
Filetti, Cristoforo; Ruscello, Bruno; D'Ottavio, Stefano; Fanelli, Vito
2017-06-01
The performance of a soccer team depends on many factors such as decision-making, cognitive and physical skills, and dynamic ever-changing space-time interactions between teammate and opponents in relation to the ball. Seventy ( n = 70) matches of the Italian SERIE A season 2013-2014 were investigated to analyze the mean performance of 360 players in terms of physical (physical efficiency index; PEI) and technical-tactical (technical efficiency index; TEI) standpoints. Using a semiautomatic video analysis system that has incorporated new parameters able to measure technical-tactical and physical efficiency (Patent IB2010/002593, 2011-ISA), the correlation between these new variables and how much it relates to the likelihood of winning were verified. Correlations between TEI and PEI were significant ( n = 140, r = .60, p < .001), and TEI showed a higher likelihood of winning than PEI factors ( p < .0001 vs. .0001, CI 95% [1.64, 3.00] vs. [1.28, 2.07]). Higher TEI and TEI + PEI differences between the teams were associated with a greater likelihood of winning, but PEI differences were not. Key performance indicators and this performance assessment method might be useful to better understand what determines winning and to assist the overall training process and match management.
Improved Kalman Filter Method for Measurement Noise Reduction in Multi Sensor RFID Systems
Eom, Ki Hwan; Lee, Seung Joon; Kyung, Yeo Sun; Lee, Chang Won; Kim, Min Chul; Jung, Kyung Kwon
2011-01-01
Recently, the range of available Radio Frequency Identification (RFID) tags has been widened to include smart RFID tags which can monitor their varying surroundings. One of the most important factors for better performance of smart RFID system is accurate measurement from various sensors. In the multi-sensing environment, some noisy signals are obtained because of the changing surroundings. We propose in this paper an improved Kalman filter method to reduce noise and obtain correct data. Performance of Kalman filter is determined by a measurement and system noise covariance which are usually called the R and Q variables in the Kalman filter algorithm. Choosing a correct R and Q variable is one of the most important design factors for better performance of the Kalman filter. For this reason, we proposed an improved Kalman filter to advance an ability of noise reduction of the Kalman filter. The measurement noise covariance was only considered because the system architecture is simple and can be adjusted by the neural network. With this method, more accurate data can be obtained with smart RFID tags. In a simulation the proposed improved Kalman filter has 40.1%, 60.4% and 87.5% less Mean Squared Error (MSE) than the conventional Kalman filter method for a temperature sensor, humidity sensor and oxygen sensor, respectively. The performance of the proposed method was also verified with some experiments. PMID:22346641
Improved Kalman filter method for measurement noise reduction in multi sensor RFID systems.
Eom, Ki Hwan; Lee, Seung Joon; Kyung, Yeo Sun; Lee, Chang Won; Kim, Min Chul; Jung, Kyung Kwon
2011-01-01
Recently, the range of available radio frequency identification (RFID) tags has been widened to include smart RFID tags which can monitor their varying surroundings. One of the most important factors for better performance of smart RFID system is accurate measurement from various sensors. In the multi-sensing environment, some noisy signals are obtained because of the changing surroundings. We propose in this paper an improved Kalman filter method to reduce noise and obtain correct data. Performance of Kalman filter is determined by a measurement and system noise covariance which are usually called the R and Q variables in the Kalman filter algorithm. Choosing a correct R and Q variable is one of the most important design factors for better performance of the Kalman filter. For this reason, we proposed an improved Kalman filter to advance an ability of noise reduction of the Kalman filter. The measurement noise covariance was only considered because the system architecture is simple and can be adjusted by the neural network. With this method, more accurate data can be obtained with smart RFID tags. In a simulation the proposed improved Kalman filter has 40.1%, 60.4% and 87.5% less mean squared error (MSE) than the conventional Kalman filter method for a temperature sensor, humidity sensor and oxygen sensor, respectively. The performance of the proposed method was also verified with some experiments.
Feniman, Mariza Ribeiro; Daniel, Bárbara Tavares; De Vitto, Luciana Paula Maximino; Lemos, Isabel Cristina Cavalcanti; Lauris, José Roberto Pereira
2008-01-01
The first two years of life are critical for the acquisition and development of hearing and speaking skills. This prospective study aims to verify the performance of infants with cleft lip and palate (CLP) with and without risk factors for hearing (RFH) in the verbal recognition test (VRT). The parents of 100 infants (9 to 18 months of age) with CLP were interviewed to investigate the presence of RFH and to sort out the characteristics of the study groups. All infants underwent VRT. Otologic diseases, lack of breastfeeding, parental smoking, upper airway insufficiency, stay in an incubator, and family history of hearing impairment were the most frequent RFH. Eighty-five infants had RFH, among which 40% had altered VRT results; fifteen did not have any RFH and 73% performed as expected for their age range in the VRT. There was no significant difference (p=0.326) between groups. Fifty-four infants had history of otitis media (OM), among which 31% had altered VRT results; forty-six had no history of OM and performed as expected for their age range in the VRT; Statistically significant difference (p=0.000) was found. Other risk factors for hearing aside CLP were found. Infants with and without history of RFH performed similarly in the VRT. The presence of otologic diseases significantly interfered with the VRT.
Nuclear Track Detector Characterization via Alpha-Spectrometry for Radioprotection Use
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morelli, D.; Imme, G.; Catalano, R.
2011-12-13
Solid Nuclear Track Detectors (SNTDs), CR-39 type, are usually adopted to monitor radon gas concentrations. In order to characterize the detectors according to track geometrical parameters, detectors were irradiated inside a vacuum chamber by alpha particles at twelve energy values, obtained by different Mylar foils in front of a {sup 241}Am source. The alpha energy values were verified using a Si detector. After the exposure to the alpha particles, the detectors were chemically etched to enlarge the tracks, which were then analyzed by means of a semiautomatic system composed of an optical microscope equipped with a CCD camera connected tomore » a personal computer to store images. A suitable routine analyzed the track parameters: major and minor axis length and mean grey level, allowing us to differentiate tracks according to the incident alpha energy and then to individuate the discrimination factors for radon alpha tracks. The combined use of geometrical and optical parameters allows one to overcome the ambiguity in the alpha energy determination due to the non-monotonicity of each parameter versus energy. After track parameter determination, a calibration procedure was performed by means of a radon chamber. The calibration was verified through an inter-comparing survey.« less
Flight motor set 360L006 (STS-34). Volume 1: System overview
NASA Technical Reports Server (NTRS)
Garecht, Diane M.
1990-01-01
Flight motor set 360L006 was launched at approximately 11:54 a.m. Central Daylight Time (CDT) on 18 October 1989 as part of NASA space shuttle mission STS-34. As with all previous redesigned solid rocket motor launches, overall motor performance was excellent. All ballistic contract end item (CEI) specification parameters were verified with the exceptions of ignition interval and rise rates. Ignition interval and rise rates could not be verified due to the elimination of developmental flight instrumentation from fourth flight and subsequent, but the low sample rate data that were available showed nominal propulsion performance. All ballistic and mass property parameters closely matched the predicted values and were well within the required CEI specification levels that could be assessed, with the exception of the RH-motor vacuum-delivered specific impulse. It exceeds the upper-limit CEI specification due to a bias imposed on the raw data by the OPT/Taber gage measurement differences. Evaluation of the ground environment instrumentation measurements again verified thermal model analysis data and showed agreement with predicted environmental effects. No launch commit criteria thermal violations occurred. Postflight inspection again verified superior performance of the insulation, phenolics, metal parts, and seals. Postflight evaluation indicated both nozzles performed as expected during flight, although splashdown loads tore the left-hand, 45-deg actuator bracket from the nozzle. All combustion gas was contained by insulation in the field and nozzle-to-case joints. Recommendations were made concerning improved thermal modeling and measurements. The rationale for these recommendations, the disposition of all anomalies, and complete result details are contained.
Crew interface with a telerobotic control station
NASA Technical Reports Server (NTRS)
Mok, Eva
1987-01-01
A method for apportioning crew-telerobot tasks has been derived to facilitate the design of a crew-friendly telerobot control station. To identify the most appropriate state-of-the-art hardware for the control station, task apportionment must first be conducted to identify if an astronaut or a telerobot is best to execute the task and which displays and controls are required for monitoring and performance. Basic steps that comprise the task analysis process are: (1) identify space station tasks; (2) define tasks; (3) define task performance criteria and perform task apportionment; (4) verify task apportionment; (5) generate control station requirements; (6) develop design concepts to meet requirements; and (7) test and verify design concepts.
2013-09-01
33 4.7 SAMPLING RESULTS ...34 5.0 PERFORMANCE RESULTS ...PERFORMANCE RESULTS DISCUSSION ............................................................................ 39 5.2.1 Energy: Verify Power Production
NASA Technical Reports Server (NTRS)
1977-01-01
Captive-active tests consisted of three mated carrier aircraft/Orbiter flights with an active manned Orbiter. The objectives of this series of flights were to (1) verify the separation profile, (2) verify the integrated structure, aerodynamics, and flight control system, (3) verify Orbiter integrated system operations, and (4) refine and finalize carrier aircraft, Orbiter crew, and ground procedures in preparation for free flight tests. A summary description of the flights is presented with assessments of flight test requirements, and of the performance operations, and of significant flight anomalies is included.
Two-Level Verification of Data Integrity for Data Storage in Cloud Computing
NASA Astrophysics Data System (ADS)
Xu, Guangwei; Chen, Chunlin; Wang, Hongya; Zang, Zhuping; Pang, Mugen; Jiang, Ping
Data storage in cloud computing can save capital expenditure and relive burden of storage management for users. As the lose or corruption of files stored may happen, many researchers focus on the verification of data integrity. However, massive users often bring large numbers of verifying tasks for the auditor. Moreover, users also need to pay extra fee for these verifying tasks beyond storage fee. Therefore, we propose a two-level verification of data integrity to alleviate these problems. The key idea is to routinely verify the data integrity by users and arbitrate the challenge between the user and cloud provider by the auditor according to the MACs and ϕ values. The extensive performance simulations show that the proposed scheme obviously decreases auditor's verifying tasks and the ratio of wrong arbitration.
Dalmolin, Graziele de Lima; Lunardi, Valéria Lerch; Lunardi, Guilherme Lerch; Barlem, Edison Luiz Devos; Silveira, Rosemary Silva da
2014-01-01
to identify relationships between moral distress and Burnout in the professional performance from the perceptions of the experiences of nursing workers. this is a survey type study with 375 nursing workers working in three different hospitals of southern Rio Grande do Sul, with the application of adaptations of the Moral Distress Scale and the Maslach Burnout Inventory, validated and standardized for use in Brazil. Data validation occurred through factor analysis and Cronbach's alpha. For the data analysis bivariate analysis using Pearson's correlation and multivariate analysis using multiple regression were performed. the existence of a weak correlation between moral distress and Burnout was verified. A possible positive correlation between Burnout and therapeutic obstinacy, and a negative correlation between professional fulfillment and moral distress were identified. the need was identified for further studies that include mediating and moderating variables that may explain more clearly the models studied.
Dalmolin, Graziele de Lima; Lunardi, Valéria Lerch; Lunardi, Guilherme Lerch; Barlem, Edison Luiz Devos; da Silveira, Rosemary Silva
2014-01-01
Objective to identify relationships between moral distress and Burnout in the professional performance from the perceptions of the experiences of nursing workers. Methods this is a survey type study with 375 nursing workers working in three different hospitals of southern Rio Grande do Sul, with the application of adaptations of the Moral Distress Scale and the Maslach Burnout Inventory, validated and standardized for use in Brazil. Data validation occurred through factor analysis and Cronbach's alpha. For the data analysis bivariate analysis using Pearson's correlation and multivariate analysis using multiple regression were performed. Results the existence of a weak correlation between moral distress and Burnout was verified. A possible positive correlation between Burnout and therapeutic obstinacy, and a negative correlation between professional fulfillment and moral distress were identified. Conclusion the need was identified for further studies that include mediating and moderating variables that may explain more clearly the models studied. PMID:24553701
Habitability Designs for Crew Exploration Vehicle
NASA Technical Reports Server (NTRS)
Woolford, Barbara
2006-01-01
NASA's space human factors team is contributing to the habitability of the Crew Exploration Vehicle (CEV), which will take crews to low Earth orbit, and dock there with additional vehicles to go on to the moon's surface. They developed a task analysis for operations and for self-sustenance (sleeping, eating, hygiene), and estimated the volumes required for performing the various tasks and for the associated equipment, tools and supplies. Rough volumetric mockups were built for crew evaluations. Trade studies were performed to determine the size and location of windows. The habitability analysis also contributes to developing concepts of operations by identifying constraints on crew time. Recently completed studies provided stowage concepts, tools for assessing lighting constraints, and approaches to medical procedure development compatible with the tight space and absence of gravity. New work will be initiated to analyze design concepts and verify that equipment and layouts do meet requirements.
Design and Analysis Tool for External-Compression Supersonic Inlets
NASA Technical Reports Server (NTRS)
Slater, John W.
2012-01-01
A computational tool named SUPIN has been developed to design and analyze external-compression supersonic inlets for aircraft at cruise speeds from Mach 1.6 to 2.0. The inlet types available include the axisymmetric outward-turning, two-dimensional single-duct, two-dimensional bifurcated-duct, and streamline-traced Busemann inlets. The aerodynamic performance is characterized by the flow rates, total pressure recovery, and drag. The inlet flowfield is divided into parts to provide a framework for the geometry and aerodynamic modeling and the parts are defined in terms of geometric factors. The low-fidelity aerodynamic analysis and design methods are based on analytic, empirical, and numerical methods which provide for quick analysis. SUPIN provides inlet geometry in the form of coordinates and surface grids useable by grid generation methods for higher-fidelity computational fluid dynamics (CFD) analysis. SUPIN is demonstrated through a series of design studies and CFD analyses were performed to verify some of the analysis results.
The aerodynamic challenges of SRB recovery
NASA Technical Reports Server (NTRS)
Bacchus, D. L.; Kross, D. A.; Moog, R. D.
1985-01-01
Recovery and reuse of the Space Shuttle solid rocket boosters was baselined to support the primary goal to develop a low cost space transportation system. The recovery system required for the 170,000-lb boosters was for the largest and heaviest object yet to be retrieved from exoatmospheric conditions. State-of-the-art design procedures were ground-ruled and development testing minimized to produce both a reliable and cost effective system. The ability to utilize the inherent drag of the boosters during the initial phase of reentry was a key factor in minimizing the parachute loads, size and weight. A wind tunnel test program was devised to enable the accurate prediction of booster aerodynamic characteristics. Concurrently, wind tunnel, rocket sled and air drop tests were performed to develop and verify the performance of the parachute decelerator subsystem. Aerodynamic problems encountered during the overall recovery system development and the respective solutions are emphasized.
Zhang, Zhihua; Sheng, Zheng; Shi, Hanqing; Fan, Zhiqiang
2016-01-01
Using the RFC technique to estimate refractivity parameters is a complex nonlinear optimization problem. In this paper, an improved cuckoo search (CS) algorithm is proposed to deal with this problem. To enhance the performance of the CS algorithm, a parameter dynamic adaptive operation and crossover operation were integrated into the standard CS (DACS-CO). Rechenberg's 1/5 criteria combined with learning factor were used to control the parameter dynamic adaptive adjusting process. The crossover operation of genetic algorithm was utilized to guarantee the population diversity. The new hybrid algorithm has better local search ability and contributes to superior performance. To verify the ability of the DACS-CO algorithm to estimate atmospheric refractivity parameters, the simulation data and real radar clutter data are both implemented. The numerical experiments demonstrate that the DACS-CO algorithm can provide an effective method for near-real-time estimation of the atmospheric refractivity profile from radar clutter. PMID:27212938
The Boeing 747 fatigue integrity program
NASA Technical Reports Server (NTRS)
Spencer, M. M.
1972-01-01
The fatigue integrity program which was established to insure economic operations and to provide foundation data for inspection and maintenance is discussed. Significant features of the 747 fatigue integrity program are: (1) fatigue analyses which are continually updated to reflect design changes, fatigue test results, and static and flight load survey measurements; (2) material selection and detail design by using initial fatigue analyses, service experience, and testing; and (3) fatigue testing to check detail design quality and to verify the analyses, culminated by the test of a structurally complete airframe. Fatigue stress analyses were performed with the aid of experimental as well as analytical procedures. Extensive application was made of the stress severity factor, developed at Boeing, for evaluating peak stresses in complex joints. A frame of reference was established by families of structural fatigue performance curves (S-N curves) encompassing the range of materials and fatigue qualities anticipated for the 747 airplane design.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tateoka, K; Graduate School of Medicine, Sapporo Medical University, Sapporo, JP; Fujimomo, K
2014-06-01
Purpose: The aim of the study is to evaluate the use of Varian DynaLog files to verify VMAT plans delivery and modulation complexity score (MCS) of VMAT. Methods: Delivery accuracy of machine performance was quantified by multileaf collimator (MLC) position errors, gantry angle errors and fluence delivery accuracy for volumetric modulated arc therapy (VMAT). The relationship between machine performance and plan complexity were also investigated using the modulation complexity score (MCS). Plan and Actual MLC positions, gantry angles and delivered fraction of monitor units were extracted from Varian DynaLog files. These factors were taken from the record and verify systemmore » of MLC control file. Planned and delivered beam data were compared to determine leaf position errors and gantry angle errors. Analysis was also performed on planned and actual fluence maps reconstructed from those of the DynaLog files. This analysis was performed for all treatment fractions of 5 prostate VMAT plans. The analysis of DynaLog files have been carried out by in-house programming in Visual C++. Results: The root mean square of leaf position and gantry angle errors were about 0.12 and 0.15, respectively. The Gamma of planned and actual fluence maps at 3%/3 mm criterion was about 99.21. The gamma of the leaf position errors were not directly related to plan complexity as determined by the MCS. Therefore, the gamma of the gantry angle errors were directly related to plan complexity as determined by the MCS. Conclusion: This study shows Varian dynalog files for VMAT plan can be diagnosed delivery errors not possible with phantom based quality assurance. Furthermore, the MCS of VMAT plan can evaluate delivery accuracy for patients receiving of VMAT. Machine performance was found to be directly related to plan complexity but this is not the dominant determinant of delivery accuracy.« less
Childhood vaccines and Kawasaki disease, Vaccine Safety Datalink, 1996-2006.
Abrams, Joseph Y; Weintraub, Eric S; Baggs, James M; McCarthy, Natalie L; Schonberger, Lawrence B; Lee, Grace M; Klein, Nicola P; Belongia, Edward A; Jackson, Michael L; Naleway, Allison L; Nordin, James D; Hambidge, Simon J; Belay, Ermias D
2015-01-03
Kawasaki disease is a childhood vascular disorder of unknown etiology. Concerns have been raised about vaccinations being a potential risk factor for Kawasaki disease. Data from the Vaccine Safety Datalink were collected on children aged 0-6 years at seven managed care organizations across the United States. Defining exposure as one of several time periods up to 42 days after vaccination, we conducted Poisson regressions controlling for age, sex, season, and managed care organization to determine if rates of physician-diagnosed and verified Kawasaki disease were elevated following vaccination compared to rates during all unexposed periods. We also performed case-crossover analyses to control for unmeasured confounding. A total of 1,721,186 children aged 0-6 years from seven managed care organizations were followed for a combined 4,417,766 person-years. The rate of verified Kawasaki disease was significantly lower during the 1-42 days after vaccination (rate ratio=0.50, 95% CL=0.27-0.92) and 8-42 days after vaccination (rate ratio=0.45, 95% CL=0.22-0.90) compared to rates during unexposed periods. Breaking down the analysis by vaccination category did not identify a subset of vaccines which was solely responsible for this association. The case-crossover analyses revealed that children with Kawasaki disease had lower rates of vaccination in the 42 days prior to symptom onset for both physician-diagnosed Kawasaki disease (rate ratio=0.79, 95% CL=0.64-0.97) and verified Kawasaki disease (rate ratio=0.38, 95% CL=0.20-0.75). Childhood vaccinations' studied did not increase the risk of Kawasaki disease; conversely, vaccination was associated with a transient decrease in Kawasaki disease incidence. Verifying and understanding this potential protective effect could yield clues to the underlying etiology of Kawasaki disease. Copyright © 2014. Published by Elsevier Ltd.
The Synergistic Effect of Affective Factors on Student Learning Outcomes
ERIC Educational Resources Information Center
Jack, Brady Michael; Lin, Huann-shyang; Yore, Larry D.
2014-01-01
This study investigates how affective and self-related factors impact participation in science learning and environmental awareness and responsibility. Using PISA 2006 datasets from Taiwan and Canada having similar level of science competency, the model for this study verifies and expands an earlier model by examining the relationships among…
ERIC Educational Resources Information Center
Benarroch, Alicia; Perez, Silvia; Perales, Javier
2011-01-01
Introduction: Variables that predict the eating behaviour of teenagers are a high-priority objective of nutritional educational programmes. This research work is designed to verify whether the "Food Consumption, Intentions and Preferences Assessment Test" (FCIPAT) is useful when investigating the factors influencing adolescent eating…
Wu, Chunwei; Guan, Qingxiao; Wang, Shumei; Rong, Yueying
2017-01-01
Root of Panax ginseng C. A. Mey (Renseng in Chinese) is a famous Traditional Chinese Medicine. Ginsenosides are the major bioactive components. However, the shortage and high cost of some ginsenoside reference standards make it is difficult for quality control of P. ginseng . A method, single standard for determination of multicomponents (SSDMC), was developed for the simultaneous determination of nine ginsenosides in P. ginseng (ginsenoside Rg 1 , Re, Rf, Rg 2 , Rb 1 , Rc, Rb 2 , Rb 3 , Rd). The analytes were separated on Inertsil ODS-3 C18 (250 mm × 4.6 mm, 5 μm) with gradient elution of acetonitrile and water. The flow rate was 1 mL/min and detection wavelength was set at 203 nm. The feasibility and accuracy of SSDMC were checked by the external standard method, and various high-performance liquid chromatographic (HPLC) instruments and chromatographic conditions were investigated to verify its applicability. Using ginsenoside Rg 1 as the internal reference substance, the contents of other eight ginsenosides were calculated according to conversion factors (F) by HPLC. The method was validated with linearity ( r 2 ≥ 0.9990), precision (relative standard deviation [RSD] ≤2.9%), accuracy (97.5%-100.8%, RSD ≤ 1.6%), repeatability, and stability. There was no significant difference between the SSDMC method and the external standard method. New SSDMC method could be considered as an ideal mean to analyze the components for which reference standards are not readily available. A method, single standard for determination of multicomponents (SSDMC), was established by high-performance liquid chromatography for the simultaneous determination of nine ginsenosides in Panax ginseng (ginsenoside Rg1, Re, Rf, Rg2, Rb1, Rc, Rb2, Rb3, Rd)Various chromatographic conditions were investigated to verify applicability of FsThe feasibility and accuracy of SSDMC were checked by the external standard method. Abbreviations used: DRT: Different value of retention time; F: Conversion factor; HPLC: High-performance Liquid Chromatography; LOD: Limit of detection; LOQ: Limit of quantitation; PD: Percent difference; PPD: 20(S)-protopanaxadiol; PPT: 20(S)-protopanaxatriol; RSD: Relative standard deviation; SSDMC: Single Standard for Determination of Multicomponents; TCM: Traditional Chinese Medicine.
Manikandan, A.; Biplab, Sarkar; David, Perianayagam A.; Holla, R.; Vivek, T. R.; Sujatha, N.
2011-01-01
For high dose rate (HDR) brachytherapy, independent treatment verification is needed to ensure that the treatment is performed as per prescription. This study demonstrates dosimetric quality assurance of the HDR brachytherapy using a commercially available two-dimensional ion chamber array called IMatriXX, which has a detector separation of 0.7619 cm. The reference isodose length, step size, and source dwell positional accuracy were verified. A total of 24 dwell positions, which were verified for positional accuracy gave a total error (systematic and random) of –0.45 mm, with a standard deviation of 1.01 mm and maximum error of 1.8 mm. Using a step size of 5 mm, reference isodose length (the length of 100% isodose line) was verified for single and multiple catheters of same and different source loadings. An error ≤1 mm was measured in 57% of tests analyzed. Step size verification for 2, 3, 4, and 5 cm was performed and 70% of the step size errors were below 1 mm, with maximum of 1.2 mm. The step size ≤1 cm could not be verified by the IMatriXX as it could not resolve the peaks in dose profile. PMID:21897562
Development of Control Models and a Robust Multivariable Controller for Surface Shape Control
DOE Office of Scientific and Technical Information (OSTI.GOV)
Winters, Scott Eric
2003-06-18
Surface shape control techniques are applied to many diverse disciplines, such as adaptive optics, noise control, aircraft flutter control and satellites, with an objective to achieve a desirable shape for an elastic body by the application of distributed control forces. Achieving the desirable shape is influenced by many factors, such as, actuator locations, sensor locations, surface precision and controller performance. Building prototypes to complete design optimizations or controller development can be costly or impractical. This shortfall, puts significant value in developing accurate modeling and control simulation approaches. This thesis focuses on the field of adaptive optics, although these developments havemore » the potential for application in many other fields. A static finite element model is developed and validated using a large aperture interferometer system. This model is then integrated into a control model using a linear least squares algorithm and Shack-Hartmann sensor. The model is successfully exercised showing functionality for various wavefront aberrations. Utilizing a verified model shows significant value in simulating static surface shape control problems with quantifiable uncertainties. A new dynamic model for a seven actuator deformable mirror is presented and its accuracy is proven through experiment. Bond graph techniques are used to generate the state space model of the multi-actuator deformable mirror including piezo-electric actuator dynamics. Using this verified model, a robust multi-input multi-output (MIMO) H ∞ controller is designed and implemented. This controller proved superior performance as compared to a standard proportional-integral controller (PI) design.« less
Adaptation and validation of the Diabetes Management Self-Efficacy Scale to Brazilian Portuguese 1
Pace, Ana Emilia; Gomes, Lilian Cristiane; Bertolin, Daniela Comelis; Loureiro, Helena Maria Almeira Macedo; Bijl, Jaap Van Der; Shortridge-Baggett, Lillie M.
2017-01-01
Objective: to perform the cultural adaptation and validation of the Diabetes Management Self-efficacy Scale for Patients with Type 2 Diabetes Mellitus with a Brazilian population sample. Method: cross-sectional methodological study in which the adaptation and validation process included the stages recommended in the literature. Construct validity and reliability were assessed with 200 adults with type 2 diabetes mellitus. Results: the items indicated by the panel of judges and by the target population were adjusted in the cultural adaptation to improve clarity and understanding. The instrument's four factors remained in the confirmatory factor analysis with factor loadings of items greater than 0.30, except for factor 4; convergent validity, verified by the multitrait-multimethod analysis, presented inter-item correlations from 0.37 to 0.92, while for discriminant validity, 100% of the items presented greater correlation in their own factors. Cronbach's coefficient alpha for the total scale was 0.78, ranging from 0.57 to 0.86 among factors. Conclusion: semantic, cultural, conceptual and idiomatic equivalences were achieved and the instrument's Brazilian version also presented psychometric properties that showed evidence of reliability and validity. Thus, it can be applied both in clinical practice and research. Self-efficacy is useful for planning and assessing educational interventions, as well as predicting behavior modification in self-care. PMID:28562700
Simulation of tropical cyclone activity over the western North Pacific based on CMIP5 models
NASA Astrophysics Data System (ADS)
Shen, Haibo; Zhou, Weican; Zhao, Haikun
2017-09-01
Based on the Coupled Model Inter-comparison Project 5 (CMIP5) models, the tropical cyclone (TC) activity in the summers of 1965-2005 over the western North Pacific (WNP) is simulated by a TC dynamically downscaling system. In consideration of diversity among climate models, Bayesian model averaging (BMA) and equal-weighed model averaging (EMA) methods are applied to produce the ensemble large-scale environmental factors of the CMIP5 model outputs. The environmental factors generated by BMA and EMA methods are compared, as well as the corresponding TC simulations by the downscaling system. Results indicate that BMA method shows a significant advantage over the EMA. In addition, impacts of model selections on BMA method are examined. To each factor, ten models with better performance are selected from 30 CMIP5 models and then conduct BMA, respectively. As a consequence, the ensemble environmental factors and simulated TC activity are similar with the results from the 30 models' BMA, which verifies the BMA method can afford corresponding weight for each model in the ensemble based on the model's predictive skill. Thereby, the existence of poor performance models will not particularly affect the BMA effectiveness and the ensemble outcomes are improved. Finally, based upon the BMA method and downscaling system, we analyze the sensitivity of TC activity to three important environmental factors, i.e., sea surface temperature (SST), large-scale steering flow, and vertical wind shear. Among three factors, SST and large-scale steering flow greatly affect TC tracks, while average intensity distribution is sensitive to all three environmental factors. Moreover, SST and vertical wind shear jointly play a critical role in the inter-annual variability of TC lifetime maximum intensity and frequency of intense TCs.
Numerical Analysis of the Performance of Millimeter-Wave RoF-Based Cellular Backhaul Links
NASA Astrophysics Data System (ADS)
Pham, Thu A.; Pham, Hien T. T.; Le, Hai-Chau; Dang, Ngoc T.
2017-08-01
In this paper, we study the performance of a next-generation cellular backhaul network that is based on a hybrid architecture using radio-over-fiber (RoF) and millimeter-wave (MMW) techniques. We develop a mathematic model and comprehensively analyze the performance of a MMW/RoF-based backhaul downlink under the impacts of various physical layer impairments originated from both optical fiber and wireless links. More specifically, the effects of nonlinear distortion, chromatic dispersion, fading, and many types of noises including shot noise, thermal noise, amplifier noise, and relative intensity noise are investigated. The numerical results show that the nonlinear distortion, fiber dispersion, and wireless fading are key factors that limit the system performance. Setting the modulation index properly helps minimize the effect of nonlinear distortion while implementing dispersion shifted optical fibers could be used to reduce the impact of dispersion and as a result, they can improve the bit-error rate. Moreover, it is also verified that, to mitigate the effect of multipath fading, remote radio heads should be located as near the remote antenna units as possible.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garnier, Ch.; Mailhe, P.; Sontheimer, F.
2007-07-01
Fuel performance is a key factor for minimizing operating costs in nuclear plants. One of the important aspects of fuel performance is fuel rod design, based upon reliable tools able to verify the safety of current fuel solutions, prevent potential issues in new core managements and guide the invention of tomorrow's fuels. AREVA is developing its future global fuel rod code COPERNIC3, which is able to calculate the thermal-mechanical behavior of advanced fuel rods in nuclear plants. Some of the best practices to achieve this goal are described, by reviewing the three pillars of a fuel rod code: the database,more » the modelling and the computer and numerical aspects. At first, the COPERNIC3 database content is described, accompanied by the tools developed to effectively exploit the data. Then is given an overview of the main modelling aspects, by emphasizing the thermal, fission gas release and mechanical sub-models. In the last part, numerical solutions are detailed in order to increase the computational performance of the code, with a presentation of software configuration management solutions. (authors)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahrens, J.S.
For over fifteen years Sandia National Laboratories has been involved in laboratory testing of biometric identification devices. The key concept of biometric identification devices is the ability for the system to identify some unique aspect of the individual rather than some object a person may be carrying or some password they are required to know. Tests were conducted to verify manufacturer`s performance claims, to determine strengths/weaknesses of devices, and to determine devices that meet the US Department of energy`s needs. However, during recent field installation, significantly different performance was observed than was predicted by laboratory tests. Although most people usingmore » the device believed it operated adequately, the performance observed was over an order of magnitude worse than predicted. The search for reasons behind this gap between the predicted and the actual performance has revealed many possible contributing factors. As engineers, the most valuable lesson to be learned from this experience is the value of scientists and engineers with (1) common sense, (2) knowledge of human behavior, (3) the ability to observe the real world, and (4) the capability to realize the significant differences between controlled experiments and actual installations.« less
Materials Safety - Not just Flammability and Toxic Offgassing
NASA Technical Reports Server (NTRS)
Pedley, Michael D.
2007-01-01
For many years, the safety community has focused on a limited subset of materials and processes requirements as key to safety: Materials flammability, Toxic offgassing, Propellant compatibility, Oxygen compatibility, and Stress-corrosion cracking. All these items are important, but the exclusive focus on these items neglects many other items that are equally important to materials safety. Examples include (but are not limited to): 1. Materials process control -- proper qualification and execution of manufacturing processes such as structural adhesive bonding, welding, and forging are crucial to materials safety. Limitation of discussions on materials process control to an arbitrary subset of processes, known as "critical processes" is a mistake, because any process where the quality of the product cannot be verified by inspection can potentially result in unsafe hardware 2 Materials structural design allowables -- development of valid design allowables when none exist in the literature requires extensive testing of multiple lots of materials and is extremely expensive. But, without valid allowables, structural analysis cannot verify structural safety 3. Corrosion control -- All forms of corrosion, not just stress corrosion, can affect structural integrity of hardware 4. Contamination control during ground processing -- contamination control is critical to manufacturing processes such as adhesive bonding and also to elimination foreign objects and debris (FOD) that are hazardous to the crew of manned spacecraft in microgravity environments. 5. Fasteners -- Fastener design, the use of verifiable secondary locking features, and proper verification of fastener torque are essential for proper structural performance This presentation discusses some of these key factors and the importance of considering them in ensuring the safety of space hardware.
30 CFR 227.601 - What are a State's responsibilities if it performs automated verification?
Code of Federal Regulations, 2010 CFR
2010-07-01
... performs automated verification? 227.601 Section 227.601 Mineral Resources MINERALS MANAGEMENT SERVICE... Perform Delegated Functions § 227.601 What are a State's responsibilities if it performs automated verification? To perform automated verification of production reports or royalty reports, you must: (a) Verify...
33 CFR 332.5 - Ecological performance standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Ecological performance standards..., DEPARTMENT OF DEFENSE COMPENSATORY MITIGATION FOR LOSSES OF AQUATIC RESOURCES § 332.5 Ecological performance... objective and verifiable. Ecological performance standards must be based on the best available science that...
EPA ENVIRONMENTAL TECHNOLOGY EXPERIENCE
THE USEPA's Environmental Technology Verification for Metal Finishing Pollution Prevention Technologies (ETV-MF) Program verifies the performance of innovative, commercial-ready technologies designed to improve industry performance and achieve cost-effective pollution prevention ...
Implemented a wireless communication system for VGA capsule endoscope.
Moon, Yeon-Kwan; Lee, Jyung Hyun; Park, Hee-Joon; Cho, Jin-Ho; Choi, Hyun-Chul
2014-01-01
Recently, several medical devices that use wireless communication are under development. In this paper, the small size frequency shift keying (FSK) transmitter and a monofilar antenna for the capsule endoscope, enabling the medical device to transmit VGA-size images of the intestine. To verify the functionality of the proposed wireless communication system, computer simulations and animal experiments were performed with the implemented capsule endoscope that includes the proposed wireless communication system. Several fundamental experiments are carried out using the implemented transmitter and antenna, and animal in-vivo experiments were performed to verify VGA image transmission.
Tomietto, Marco; Saiani, Luisa; Palese, Alvisa; Cunico, Laura; Cicolini, Giancarlo; Watson, Paul; Saarikoski, Mikko
2012-01-01
A clinical learning environment is an "interactive network of forces within the clinical setting that influence the students' learning outcomes". International research indicates the Clinical Learning Environment and Supervision plus Nurse Teacher scale (CLES+T) as the gold standard to assess a good clinical learning environment. This study aims to evaluate the psychometric proprieties of CLES+T Italian version. 875 students attending the Bachelor in Nursing in 3 Universities in Italy participated in the study. Cronbach's alpha, item to total correlations, skewness and kurtosis were calculated; factor analysis was performed using Principal Axis Factoring and an oblique rotation method. Results showed a Cronbach's alpha of 0.95 of the scale and ranging from 0.80 to 0.96 among factors; all items verified item to total correlation and answers' variability criteria. Factor analysis showed a 7-factors model as explaining more than 67% of the variance, the higher variance was explained by the "pedagogical atmosphere" factor (37.61%). The nurse teacher factor in the Italian model is split into 3 sub-factors: theory-practice integration, cooperation with ward staff and relationship with mentor and student. These results enable an international debate concerning the theoretical structure of CLES+T and provide a reliable and valid tool for the comparison of supervisory models in guiding nursing students' clinical learning.
Optimal dental age estimation practice in United Arab Emirates' children.
Altalie, Salem; Thevissen, Patrick; Fieuws, Steffen; Willems, Guy
2014-03-01
The aim of the study was to detect whether the Willems model, developed on a Belgian reference sample, can be used for age estimations in United Arab Emirates (UAE) children. Furthermore, it was verified that if added third molars development information in children provided more accurate age predictions. On 1900 panoramic radiographs, the development of left mandibular permanent teeth (PT) and third molars (TM) was registered according the Demirjian and the Kohler technique, respectively. The PT data were used to verify the Willems model and to develop a UAE model and to verify it. Multiple regression models with PT, TM, and PT + TM scores as independent and age as dependent factor were developed. Comparing the verified Willems- and the UAE model revealed differences in mean error of -0.01 year, mean absolute error of 0.01 year and root mean squared error of 0.90 year. Neglectable overall decrease in RMSE was detected combining PM and TM developmental information. © 2013 American Academy of Forensic Sciences.
The HACMS program: using formal methods to eliminate exploitable bugs
Launchbury, John; Richards, Raymond
2017-01-01
For decades, formal methods have offered the promise of verified software that does not have exploitable bugs. Until recently, however, it has not been possible to verify software of sufficient complexity to be useful. Recently, that situation has changed. SeL4 is an open-source operating system microkernel efficient enough to be used in a wide range of practical applications. Its designers proved it to be fully functionally correct, ensuring the absence of buffer overflows, null pointer exceptions, use-after-free errors, etc., and guaranteeing integrity and confidentiality. The CompCert Verifying C Compiler maps source C programs to provably equivalent assembly language, ensuring the absence of exploitable bugs in the compiler. A number of factors have enabled this revolution, including faster processors, increased automation, more extensive infrastructure, specialized logics and the decision to co-develop code and correctness proofs rather than verify existing artefacts. In this paper, we explore the promise and limitations of current formal-methods techniques. We discuss these issues in the context of DARPA’s HACMS program, which had as its goal the creation of high-assurance software for vehicles, including quadcopters, helicopters and automobiles. This article is part of the themed issue ‘Verified trustworthy software systems’. PMID:28871050
The HACMS program: using formal methods to eliminate exploitable bugs.
Fisher, Kathleen; Launchbury, John; Richards, Raymond
2017-10-13
For decades, formal methods have offered the promise of verified software that does not have exploitable bugs. Until recently, however, it has not been possible to verify software of sufficient complexity to be useful. Recently, that situation has changed. SeL4 is an open-source operating system microkernel efficient enough to be used in a wide range of practical applications. Its designers proved it to be fully functionally correct, ensuring the absence of buffer overflows, null pointer exceptions, use-after-free errors, etc., and guaranteeing integrity and confidentiality. The CompCert Verifying C Compiler maps source C programs to provably equivalent assembly language, ensuring the absence of exploitable bugs in the compiler. A number of factors have enabled this revolution, including faster processors, increased automation, more extensive infrastructure, specialized logics and the decision to co-develop code and correctness proofs rather than verify existing artefacts. In this paper, we explore the promise and limitations of current formal-methods techniques. We discuss these issues in the context of DARPA's HACMS program, which had as its goal the creation of high-assurance software for vehicles, including quadcopters, helicopters and automobiles.This article is part of the themed issue 'Verified trustworthy software systems'. © 2017 The Authors.
ERIC Educational Resources Information Center
Saengprom, Narumon; Erawan, Waraporn; Damrongpanit, Suntonrapot; Sakulku, Jaruwan
2015-01-01
The purposes of this study were 1) Compare analytical thinking ability by testing the same sets of students 5 times 2) Develop and verify whether analytical thinking ability of students corresponds to second-order growth curve factors model. Samples were 1,093 eighth-grade students. The results revealed that 1) Analytical thinking ability scores…
Study on verifying the angle measurement performance of the rotary-laser system
NASA Astrophysics Data System (ADS)
Zhao, Jin; Ren, Yongjie; Lin, Jiarui; Yin, Shibin; Zhu, Jigui
2018-04-01
An angle verification method to verify the angle measurement performance of the rotary-laser system was developed. Angle measurement performance has a great impact on measuring accuracy. Although there is some previous research on the verification of angle measuring uncertainty for the rotary-laser system, there are still some limitations. High-precision reference angles are used in the study of the method, and an integrated verification platform is set up to evaluate the performance of the system. This paper also probes the error that has biggest influence on the verification system. Some errors of the verification system are avoided via the experimental method, and some are compensated through the computational formula and curve fitting. Experimental results show that the angle measurement performance meets the requirement for coordinate measurement. The verification platform can evaluate the uncertainty of angle measurement for the rotary-laser system efficiently.
Single-state electronic ballast with dimming feature and unity power factor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, T.F.; Yu, T.H.; Chiang, M.C.
1998-05-01
Analysis, design, and practical consideration of a single-stage electronic ballast with dimming feature and unity power factor are presented in this paper. The proposed single-stage ballast is the combination of a boost converter and a half-bridge series-resonant parallel-loaded inverter. The boost semistage working in the discontinuous conduction mode functions as a power factor corrector and the inverter semistage operated above resonance are employed to ballast the lamp. Replacing the lamp with the plasma model, analysis of the ballast is fulfilled. The dimming feature is carried out by pulse-width modulation (PWM) and variable-frequency controls simultaneously. The proposed single-stage ballast is suitablemore » for applications with moderate power level and low-line voltage while requiring a high-output voltage. It can save a controller, an active switch and its driver, reduce size, and possibly increase system reliability while requiring two additional diodes over a conventional two-stage system. A prototype was implemented to verify the theoretical discussion. The hardware measurements have shown that the desired performance can be achieved feasibly.« less
A control method for bilateral teleoperating systems
NASA Astrophysics Data System (ADS)
Strassberg, Yesayahu
1992-01-01
The thesis focuses on control of bilateral master-slave teleoperators. The bilateral control issue of teleoperators is studied and a new scheme that overcomes basic unsolved problems is proposed. A performance measure, based on the multiport modeling method, is introduced in order to evaluate and understand the limitations of earlier published bilateral control laws. Based on the study evaluating the different methods, the objective of the thesis is stated. The proposed control law is then introduced, its ideal performance is demonstrated, and conditions for stability and robustness are derived. It is shown that stability, desired performance, and robustness can be obtained under the assumption that the deviation of the model from the actual system satisfies certain norm inequalities and the measurement uncertainties are bounded. The proposed scheme is validated by numerical simulation. The simulated system is based on the configuration of the RAL (Robotics and Automation Laboratory) telerobot. From the simulation results it is shown that good tracking performance can be obtained. In order to verify the performance of the proposed scheme when applied to a real hardware system, an experimental setup of a three degree of freedom master-slave teleoperator (i.e. three degree of freedom master and three degree of freedom slave robot) was built. Three basic experiments were conducted to verify the performance of the proposed control scheme. The first experiment verified the master control law and its contribution to the robustness and performance of the entire system. The second experiment demonstrated the actual performance of the system while performing a free motion teleoperating task. From the experimental results, it is shown that the control law has good performance and is robust to uncertainties in the models of the master and slave.
TrustGuard: A Containment Architecture with Verified Output
2017-01-01
that the TrustGuard system has minimal performance decline, despite restrictions such as high communication latency and limited available bandwidth...design are the availability of high bandwidth and low delays between the host and the monitoring chip. 3-D integration provides an alternate way of...TRUSTGUARD: A CONTAINMENT ARCHITECTURE WITH VERIFIED OUTPUT SOUMYADEEP GHOSH A DISSERTATION PRESENTED TO THE FACULTY OF PRINCETON UNIVERSITY IN
Park, Sung Hwan; Lee, Ji Min; Kim, Jong Shik
2013-01-01
An irregular performance of a mechanical-type constant power regulator is considered. In order to find the cause of an irregular discharge flow at the cut-off pressure area, modeling and numerical simulations are performed to observe dynamic behavior of internal parts of the constant power regulator system for a swashplate-type axial piston pump. The commercial numerical simulation software AMESim is applied to model the mechanical-type regulator with hydraulic pump and simulate the performance of it. The validity of the simulation model of the constant power regulator system is verified by comparing simulation results with experiments. In order to find the cause of the irregular performance of the mechanical-type constant power regulator system, the behavior of main components such as the spool, sleeve, and counterbalance piston is investigated using computer simulation. The shape modification of the counterbalance piston is proposed to improve the undesirable performance of the mechanical-type constant power regulator. The performance improvement is verified by computer simulation using AMESim software.
Performance of the NIRS fast scanning system for heavy-ion radiotherapy.
Furukawa, Takuji; Inaniwa, Taku; Sato, Shinji; Shirai, Toshiyuki; Takei, Yuka; Takeshita, Eri; Mizushima, Kota; Iwata, Yoshiyuki; Himukai, Takeshi; Mori, Shinichiro; Fukuda, Shigekazu; Minohara, Shinichi; Takada, Eiichi; Murakami, Takeshi; Noda, Koji
2010-11-01
A project to construct a new treatment facility, as an extension of the existing HIMAC facility, has been initiated for the further development of carbon-ion therapy at NIRS. This new treatment facility is equipped with a 3D irradiation system with pencil-beam scanning. The challenge of this project is to realize treatment of a moving target by scanning irradiation. To achieve fast rescanning within an acceptable irradiation time, the authors developed a fast scanning system. In order to verify the validity of the design and to demonstrate the performance of the fast scanning prior to use in the new treatment facility, a new scanning-irradiation system was developed and installed into the existing HIMAC physics-experiment course. The authors made strong efforts to develop (1) the fast scanning magnet and its power supply, (2) the high-speed control system, and (3) the beam monitoring. The performance of the system including 3D dose conformation was tested by using the carbon beam from the HIMAC accelerator. The performance of the fast scanning system was verified by beam tests. Precision of the scanned beam position was less than +/-0.5 mm. By cooperating with the planning software, the authors verified the homogeneity of the delivered field within +/-3% for the 3D delivery. This system took only 20 s to deliver the physical dose of 1 Gy to a spherical target having a diameter of 60 mm with eight rescans. In this test, the average of the spot-staying time was considerably reduced to 154 micros, while the minimum staying time was 30 micros. As a result of this study, the authors verified that the new scanning delivery system can produce an accurate 3D dose distribution for the target volume in combination with the planning software.
SHOOT performance testing. [Superfluid Helium On-Orbit Transfer Flight Demonstration
NASA Technical Reports Server (NTRS)
Dipirro, M. J.; Shirron, P. J.; Volz, S. M.; Schein, M. E.
1991-01-01
The Superfluid Helium On-Orbit Transfer (SHOOT) Flight Demonstration is a shuttle attached payload designed to demonstrate the technology necessary to resupply liquid helium dewars in space. Many SHOOT components will also have use in other aerospace cryogenic systems. The first of two SHOOT dewar systems has been fabricated. The ground performance testing of this dewar is described. The performance tests include measurements of heat leak, impedances of the two vent lines, heat pulse mass gauging accuracy, and superfluid transfer parameters such as flow rate and efficiency. A laboratory dewar was substituted for the second flight dewar for the transfer tests. These tests enable a precise analytical model of the transfer process to be verified. SHOOT performance is thus quantified, except for components such as the liquid acquisition devices and a phase separator which cannot be verified in one gravity.
Performance Reports: Mirror alignment system performance prediction comparison between SAO and EKC
NASA Technical Reports Server (NTRS)
Tananbaum, H. D.; Zhang, J. P.
1994-01-01
The objective of this study is to perform an independent analysis of the residual high resolution mirror assembly (HRMA) mirror distortions caused by force and moment errors in the mirror alignment system (MAS) to statistically predict the HRMA performance. These performance predictions are then compared with those performed by Kodak to verify their analysis results.
Root Causes of the Housing Bubble
NASA Astrophysics Data System (ADS)
Kaizoji, Taisei
In this chapter we investigate root causes of the recent US housing bubble which has been caused a serious downturn in US economic growth since autumn of 2008. We propose a simple model of housing markets in order to indicate the possible determinants of recent housing prices. Utilizing the model, we verify a number of hypotheses which have been proposed in the recent literature on the housing bubbles. We suggest that the main causes of the housing bubble from 2000 to 2006 are (1) non-elastic housing supply in the metropolitan areas, and (2) declines in the mortgage loan rate and the housing premium by the massive mortgage credit expansion. We also suggest that these factors were strongly influenced by policies that governments and the Federal Reserve Board performed.
The relationship between biomechanical variables and driving performance during the golf swing.
Chu, Yungchien; Sell, Timothy C; Lephart, Scott M
2010-09-01
Swing kinematic and ground reaction force data from 308 golfers were analysed to identify the variables important to driving ball velocity. Regression models were applied at four selected events in the swing. The models accounted for 44-74% of variance in ball velocity. Based on the regression analyses, upper torso-pelvis separation (the X-Factor), delayed release (i.e. the initiation of movement) of the arms and wrists, trunk forward and lateral tilting, and weight-shifting during the swing were significantly related to ball velocity. Our results also verify several general coaching ideas that were considered important to increased ball velocity. The results of this study may serve as both skill and strength training guidelines for golfers.
FPGA-based real-time phase measuring profilometry algorithm design and implementation
NASA Astrophysics Data System (ADS)
Zhan, Guomin; Tang, Hongwei; Zhong, Kai; Li, Zhongwei; Shi, Yusheng
2016-11-01
Phase measuring profilometry (PMP) has been widely used in many fields, like Computer Aided Verification (CAV), Flexible Manufacturing System (FMS) et al. High frame-rate (HFR) real-time vision-based feedback control will be a common demands in near future. However, the instruction time delay in the computer caused by numerous repetitive operations greatly limit the efficiency of data processing. FPGA has the advantages of pipeline architecture and parallel execution, and it fit for handling PMP algorithm. In this paper, we design a fully pipelined hardware architecture for PMP. The functions of hardware architecture includes rectification, phase calculation, phase shifting, and stereo matching. The experiment verified the performance of this method, and the factors that may influence the computation accuracy was analyzed.
NASA Technical Reports Server (NTRS)
Paul, Heather L.; Jennings, Mallory A.; Waguespack, Glenn
2010-01-01
The Trace Contaminant Control System (TCCS), located within the ventilation loop of the Constellation Space Suit Portable Life Support System (PLSS), is responsible for removing hazardous trace contaminants from the space suit ventilation flow. This paper summarizes the results of a trade study that evaluated if trace contaminant control could be accomplished without a TCCS, relying on suit leakage, ullage loss from the carbon dioxide and humidity control system, and other factors. Trace contaminant generation rates were revisited to verify that values reflect the latest designs for Constellation Space Suit System (CSSS) pressure garment materials and PLSS hardware. Additionally, TCCS sizing calculations were performed and a literature survey was conducted to review the latest developments in trace contaminant technologies.
Negative measurement sensitivity values of planar capacitive imaging probes
NASA Astrophysics Data System (ADS)
Yin, Xiaokang; Chen, Guoming; Li, Wei; Hutchins, David
2014-02-01
The measurement sensitivity distribution of planar capacitive imaging (CI) probes describes how effectively each region in the sensing area is contributing to the measured charge signal on the sensing electrode. It can be used to determine the imaging ability of a CI probe. It is found in previous work that, there are regions in the sensing area where the change of the charge output and the change of targeting physical parameter are of opposite trends. This opposite correlation implies that the measurement sensitivity values in such regions are negative. In this work, the cause of negative sensitivity is discussed. Experiments are also designed and performed so as to verify the existence of negative sensitivity and study the factors that may affect the negative sensitivity distributions.
Evaluation of subsurface damage in concrete deck joints using impact echo method
Rickard, Larry; Choi, Wonchang
2016-01-01
Many factors can affect the overall performance and longevity of highway bridges, including the integrity of their deck joints. This study focuses on the evaluation of subsurface damage in deteriorated concrete deck joints, which includes the delamination and corrosion of the reinforcement. Impact echo and surface wave technology, mainly a portable seismic property analyzer (PSPA), were employed to evaluate the structural deficiency of concrete joints. Laboratory tests of core samples were conducted to verify the nondestructive test results. As a result, the primary advantage of the PSPA as a bridge assessment tool lies in its ability to assess the concrete’smore » modulus and to detect subsurface defects at a particular point simultaneously.« less
Rigorous high-precision enclosures of fixed points and their invariant manifolds
NASA Astrophysics Data System (ADS)
Wittig, Alexander N.
The well established concept of Taylor Models is introduced, which offer highly accurate C0 enclosures of functional dependencies, combining high-order polynomial approximation of functions and rigorous estimates of the truncation error, performed using verified arithmetic. The focus of this work is on the application of Taylor Models in algorithms for strongly non-linear dynamical systems. A method is proposed to extend the existing implementation of Taylor Models in COSY INFINITY from double precision coefficients to arbitrary precision coefficients. Great care is taken to maintain the highest efficiency possible by adaptively adjusting the precision of higher order coefficients in the polynomial expansion. High precision operations are based on clever combinations of elementary floating point operations yielding exact values for round-off errors. An experimental high precision interval data type is developed and implemented. Algorithms for the verified computation of intrinsic functions based on the High Precision Interval datatype are developed and described in detail. The application of these operations in the implementation of High Precision Taylor Models is discussed. An application of Taylor Model methods to the verification of fixed points is presented by verifying the existence of a period 15 fixed point in a near standard Henon map. Verification is performed using different verified methods such as double precision Taylor Models, High Precision intervals and High Precision Taylor Models. Results and performance of each method are compared. An automated rigorous fixed point finder is implemented, allowing the fully automated search for all fixed points of a function within a given domain. It returns a list of verified enclosures of each fixed point, optionally verifying uniqueness within these enclosures. An application of the fixed point finder to the rigorous analysis of beam transfer maps in accelerator physics is presented. Previous work done by Johannes Grote is extended to compute very accurate polynomial approximations to invariant manifolds of discrete maps of arbitrary dimension around hyperbolic fixed points. The algorithm presented allows for automatic removal of resonances occurring during construction. A method for the rigorous enclosure of invariant manifolds of continuous systems is introduced. Using methods developed for discrete maps, polynomial approximations of invariant manifolds of hyperbolic fixed points of ODEs are obtained. These approximations are outfit with a sharp error bound which is verified to rigorously contain the manifolds. While we focus on the three dimensional case, verification in higher dimensions is possible using similar techniques. Integrating the resulting enclosures using the verified COSY VI integrator, the initial manifold enclosures are expanded to yield sharp enclosures of large parts of the stable and unstable manifolds. To demonstrate the effectiveness of this method, we construct enclosures of the invariant manifolds of the Lorenz system and show pictures of the resulting manifold enclosures. To the best of our knowledge, these enclosures are the largest verified enclosures of manifolds in the Lorenz system in existence.
Zuo, Jian; Shi, Gui Min; Wei, Shawn; Chung, Tai-Shung
2014-08-27
Novel composite membranes comprising sulfonated styrenic Nexar pentablock copolymers were developed by dip-coating on poly(ether imide) hollow fibers for pervaporation dehydration of C2-C4 alcohols. The advantages of using block copolymers as the selective layer are (1) their effectiveness to synergize the physicochemical properties of different chemical and structural moieties and (2) tunable nanoscale morphology and nanostructure via molecular engineering. To achieve high-performance composite membranes, the effects of coating time, ion exchange capacity (IEC) of the copolymer, and solvent systems for coating were investigated. It is revealed that a minimum coating time of 30 s is needed for the formation of a continuous and less-defective top layer. A higher IEC value results in a membrane with a higher flux and lower separation factor because of enhanced hydrophilicity and stretched chain conformation. Moreover, the composite membranes prepared from hexane/ethanol mixtures show higher separation factors and lower fluxes than those from the hexane solvent owing to microdomain segregation induced by ethanol and a smooth and dense top selective layer. These hypotheses were verified by atomic force microscopy and positron annihilation spectroscopy. The newly developed composite membranes demonstrate impressive separation performance with fluxes exceeding 2 kg/m(2) h and separation factors more than 200 for isopropyl alcohol and n-butanol dehydration from 85/15 wt % alcohol/water feed mixtures at 50 °C.
Waber, Deborah P; Boiselle, Ellen C; Forbes, Peter W; Girard, Jonathan M; Sideridis, Georgios D
2018-05-01
Learning problems (LP) can have wider implications than the academic deficits per se. The goal of the present series of studies was to develop a reliable and valid quality-of-life measure targeted to children and adolescents with LP. In Study 1, using a 35-item questionnaire, we surveyed 151 parents/guardians of children referred for assessment of learning disorders. Exploratory factor analysis identified a three-factor model: Academic Performance, School Understanding, and Child/Family Psychological. These factors were validated against standardized measures of academic achievement and psychosocial functioning. The questionnaire was then reduced to 15 items-the LD/QOL15 -and administered to a community sample of 325 parents/guardians of children in Grades 1 to 8 (Study 2). The three-factor model was verified with confirmatory factor analysis. Comparison of general education ( n = 232) and LP ( n = 93) groups within the community sample documented substantial group differences ( p < .0001), with the LP group having higher mean scores. These differences were larger for older students (Grades 5-8) than younger students (Grades 1-4; p < .01). The LD/QOL15 is a brief and reliable measure that is valid to assess quality of life and, potentially, outcomes in children and adolescents with LP.
ERIC Educational Resources Information Center
Stuive, Ilse; Kiers, Henk A. L.; Timmerman, Marieke E.; ten Berge, Jos M. F.
2008-01-01
This study compares two confirmatory factor analysis methods on their ability to verify whether correct assignments of items to subtests are supported by the data. The confirmatory common factor (CCF) method is used most often and defines nonzero loadings so that they correspond to the assignment of items to subtests. Another method is the oblique…
Genetic factors in familial aggregation of blood pressure of Portuguese nuclear families.
Fermino, Rogério César; Seabra, André; Garganta, Rui; Maia, José António Ribeiro
2009-03-01
Despite of the increase in the prevalence of hypertension in Portugal, the importance of genetic factors in blood pressure (BP) has not been studied extensively in our country. To verify the indirect presence of vertical transmission of genetic factors between parents and children in BP values, and to estimate the magnitude of genetic factors contributing for variation in BP values in the population. Sample size comprises 367 individuals (164 parents and 203 children) pertaining the 107 nuclear families participating in 'Familias Activas' project, proceeding from different regions of North Portugal. The BP was measured with Omron model M6 (HEM-7001-E) digital device. SPSS 15.0 was used for data analysis; PEDSTATS was used to verify the structure of each family data. Familial correlations and heritability estimates were computed in FCOR and ASSOC modules of S.A.G.E. version 5.3. For systolic BP (SBP), correlation values were low to moderate (0.21< or = r < or =0.35); for diastolic BP (DBP) values were found to be moderate (0.24< or = r < or =0. 50). Genetic factors explain 43 and 49% of the total variation in SBP and DBP, respectively. A moderate amount of the SBP and the DBP is accounted for by genetic factors.
Cryogenically formed prestressed composite fiber-metal structures for O2/N2 high pressure gas tanks.
NASA Technical Reports Server (NTRS)
Gleich, D.
1971-01-01
Demonstration of high-structural-performance ARDEFORM cryoformed 301 stainless-steel glass-fiber-reinforced (GFR) vessels by room temperature tests of 13 1/2-in. diam spheres. Tests verified that the structural performance of ARDEFORM spherical GFR vessels not only exceeded that of all metal construction, but also bettered previous GFR experimental results by 50%. Achievement of essentially the full strength of fiberglass in a spherical wrap pattern was again verified. Significant weight advantages for this construction are projected for O2/N2 high-pressure gas tanks for Space Shuttle environmental control/life support system missions.
33 CFR 332.5 - Ecological performance standards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... whether the project is achieving its objectives. Performance standards should relate to the objectives of the compensatory mitigation project, so that the project can be objectively evaluated to determine if... objective and verifiable. Ecological performance standards must be based on the best available science that...
33 CFR 332.5 - Ecological performance standards.
Code of Federal Regulations, 2012 CFR
2012-07-01
... whether the project is achieving its objectives. Performance standards should relate to the objectives of the compensatory mitigation project, so that the project can be objectively evaluated to determine if... objective and verifiable. Ecological performance standards must be based on the best available science that...
33 CFR 332.5 - Ecological performance standards.
Code of Federal Regulations, 2013 CFR
2013-07-01
... whether the project is achieving its objectives. Performance standards should relate to the objectives of the compensatory mitigation project, so that the project can be objectively evaluated to determine if... objective and verifiable. Ecological performance standards must be based on the best available science that...
33 CFR 332.5 - Ecological performance standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... whether the project is achieving its objectives. Performance standards should relate to the objectives of the compensatory mitigation project, so that the project can be objectively evaluated to determine if... objective and verifiable. Ecological performance standards must be based on the best available science that...
Factor analysis of the Hamilton Depression Rating Scale in Parkinson's disease.
Broen, M P G; Moonen, A J H; Kuijf, M L; Dujardin, K; Marsh, L; Richard, I H; Starkstein, S E; Martinez-Martin, P; Leentjens, A F G
2015-02-01
Several studies have validated the Hamilton Depression Rating Scale (HAMD) in patients with Parkinson's disease (PD), and reported adequate reliability and construct validity. However, the factorial validity of the HAMD has not yet been investigated. The aim of our analysis was to explore the factor structure of the HAMD in a large sample of PD patients. A principal component analysis of the 17-item HAMD was performed on data of 341 PD patients, available from a previous cross sectional study on anxiety. An eigenvalue ≥1 was used to determine the number of factors. Factor loadings ≥0.4 in combination with oblique rotations were used to identify which variables made up the factors. Kaiser-Meyer-Olkin measure (KMO), Cronbach's alpha, Bartlett's test, communality, percentage of non-redundant residuals and the component correlation matrix were computed to assess factor validity. KMO verified the sample's adequacy for factor analysis and Cronbach's alpha indicated a good internal consistency of the total scale. Six factors had eigenvalues ≥1 and together explained 59.19% of the variance. The number of items per factor varied from 1 to 6. Inter-item correlations within each component were low. There was a high percentage of non-redundant residuals and low communality. This analysis demonstrates that the factorial validity of the HAMD in PD is unsatisfactory. This implies that the scale is not appropriate for studying specific symptom domains of depression based on factorial structure in a PD population. Copyright © 2014 Elsevier Ltd. All rights reserved.
Factors Associated with High Levels of Physical Activity among Adults with Intellectual Disability
ERIC Educational Resources Information Center
Temple, Viviene A.
2009-01-01
The aim was to identify factors associated with physical activity participation among active (i.e. more than or equal to 10 000 steps per day) individuals with intellectual disability. Staff at day program and supported employment organizations were asked to identify individuals they believed were physically active. To verify participants were…
Suicide, Schizophrenia, and Schizoid-Type Psychosis: Role of Life Events and Childhood Factors
ERIC Educational Resources Information Center
Tousignant, Michel; Pouliot, Louise; Routhier, Danielle; Vrakas, Georgia; McGirr, Alexander; Turecki, Gustavo
2011-01-01
The first objective was to identify the provoking events of suicide in patients with schizophrenia or schizoid-type disorder, and to assess the humiliation component of these events. The second objective was to verify if quality of care during childhood is a vulnerability factor for suicide in patients with schizophrenia or schizoid-type…
ERIC Educational Resources Information Center
Nota, Laura; Ferrari, Lea; Soresi, Salvatore
2007-01-01
The quality of life experienced by social and healthcare professionals is among the factors that contribute to the definition of quality of service. Other factors seemingly in relation with experienced quality of life concern one's own efficacy, beliefs, and burnout. The present study intended to verify the relations that existed between these…
ERIC Educational Resources Information Center
Lee, Eunsang
2017-01-01
This study investigated the gender difference among South Korean high school students in science learning motivation, technology learning motivation, and concern related engineering, as well as the correlation between these factors. It also verified effects of the sub-factors of science learning motivation and technology learning motivation on…
Influence of context in social participation of people with disabilities in Brazil.
Silva, Fabiana C M; Sampaio, Rosana F; Ferreira, Fabiane R; Camargos, Vitor P; Neves, Jorge A
2013-10-01
To identify environmental and personal factors associated with social participation in adults with various diseases/health conditions residing in the urban areas of the Belo Horizonte Metropolitan Region, Minas Gerais, Brazil. Individual characteristics, social participation, and perception of environmental barriers of 226 patients treated at a public rehabilitation referral service were evaluated. Regression analyses with hierarchical entry of data were performed to verify the association of personal and environmental factors with social participation. More years of schooling, being engaged in the labor market, and consuming alcohol are conditions that increase the social participation of patients. Natural environment, transportation, access to health services, and social capital are perceived as the most important barriers to participation. Based on the linear regression analysis, the adjusted coefficient (R²(adj)) of the full model was 0.42 (P = 0.000). The results of this study may contribute to the planning and implementation of interventions and public policies at the individual and contextual level that are considered appropriate for reducing barriers and facilitate full participation.
Comprehensive model for predicting perceptual image quality of smart mobile devices.
Gong, Rui; Xu, Haisong; Luo, M R; Li, Haifeng
2015-01-01
An image quality model for smart mobile devices was proposed based on visual assessments of several image quality attributes. A series of psychophysical experiments were carried out on two kinds of smart mobile devices, i.e., smart phones and tablet computers, in which naturalness, colorfulness, brightness, contrast, sharpness, clearness, and overall image quality were visually evaluated under three lighting environments via categorical judgment method for various application types of test images. On the basis of Pearson correlation coefficients and factor analysis, the overall image quality could first be predicted by its two constituent attributes with multiple linear regression functions for different types of images, respectively, and then the mathematical expressions were built to link the constituent image quality attributes with the physical parameters of smart mobile devices and image appearance factors. The procedure and algorithms were applicable to various smart mobile devices, different lighting conditions, and multiple types of images, and performance was verified by the visual data.
Study of the combined effects of ripeness and production area on Bosana oil's quality.
Morrone, Lucia; Neri, Luisa; Cantini, Claudio; Alfei, Barbara; Rotondi, Annalisa
2018-04-15
The effects of olive ripeness, areas of production and their interaction on the chemical and sensory characteristics of cv. Bosana oil were assessed. The study was carried out in three areas of the Sassari province, Sardinia (Italy), at three stages of maturation. The results indicated the independence of the two factors: ripeness influenced saturated fatty acids, pigment content and deacetoxy oleuropein aglycone (DAOA) content and didn't affect the sensory characteristics, while production area influenced unsaturated fatty acids, content of vanillic acid and some sensory characters. In order to verify the interdependency of the two factors, statistical analyses (two-way ANOVA) were performed. Our study showed that a thoughtful planning of harvest times and production area could allow to obtain Bosana virgin olive oil of the highest quality. Furthermore, utilizing cultivars that maintain the properties of their oils even at late dates of harvest, it would be possible to optimize harvest times. Copyright © 2017 Elsevier Ltd. All rights reserved.
An isolated bridgeless AC-DC PFC converter using a LC resonant voltage doubler rectifier
NASA Astrophysics Data System (ADS)
Lee, Sin-woo; Do, Hyun-Lark
2016-12-01
This paper proposed an isolated bridgeless AC-DC power factor correction (PFC) converter using a LC resonant voltage doubler rectifier. The proposed converter is based on isolated conventional single-ended primary inductance converter (SEPIC) PFC converter. The conduction loss of rectification is reduced than a conventional one because the proposed converter is designed to eliminate a full-bridge rectifier at an input stage. Moreover, for zero-current switching (ZCS) operation and low voltage stresses of output diodes, the secondary of the proposed converter is designed as voltage doubler with a LC resonant tank. Additionally, an input-output electrical isolation is provided for safety standard. In conclusion, high power factor is achieved and efficiency is improved. The operational principles, steady-state analysis and design equations of the proposed converter are described in detail. Experimental results from a 60 W prototype at a constant switching frequency 100 kHz are presented to verify the performance of the proposed converter.
Replicating the Z iron opacity experiments on the NIF
NASA Astrophysics Data System (ADS)
Perry, T. S.; Heeter, R. F.; Opachich, Y. P.; Ross, P. W.; Kline, J. L.; Flippo, K. A.; Sherrill, M. E.; Dodd, E. S.; DeVolder, B. G.; Cardenas, T.; Archuleta, T. N.; Craxton, R. S.; Zhang, R.; McKenty, P. W.; Garcia, E. M.; Huffman, E. J.; King, J. A.; Ahmed, M. F.; Emig, J. A.; Ayers, S. L.; Barrios, M. A.; May, M. J.; Schneider, M. B.; Liedahl, D. A.; Wilson, B. G.; Urbatsch, T. J.; Iglesias, C. A.; Bailey, J. E.; Rochau, G. A.
2017-06-01
X-ray opacity is a crucial factor of all radiation-hydrodynamics calculations, yet it is one of the least validated of the material properties in the simulation codes. Recent opacity experiments at the Sandia Z-machine have shown up to factors of two discrepancies between theory and experiment, casting doubt on the validity of the opacity models. Therefore, a new experimental opacity platform is being developed on the National Ignition Facility (NIF) not only to verify the Z-machine experimental results but also to extend the experiments to other temperatures and densities. The first experiments will be directed towards measuring the opacity of iron at a temperature of ∼160 eV and an electron density of ∼7 × 1021 cm-3. Preliminary experiments on NIF have demonstrated the ability to create a sufficiently bright point backlighter using an imploding plastic capsule and also a hohlraum that can heat the opacity sample to the desired conditions. The first of these iron opacity experiments is expected to be performed in 2017.
Probabilistic analysis of a materially nonlinear structure
NASA Technical Reports Server (NTRS)
Millwater, H. R.; Wu, Y.-T.; Fossum, A. F.
1990-01-01
A probabilistic finite element program is used to perform probabilistic analysis of a materially nonlinear structure. The program used in this study is NESSUS (Numerical Evaluation of Stochastic Structure Under Stress), under development at Southwest Research Institute. The cumulative distribution function (CDF) of the radial stress of a thick-walled cylinder under internal pressure is computed and compared with the analytical solution. In addition, sensitivity factors showing the relative importance of the input random variables are calculated. Significant plasticity is present in this problem and has a pronounced effect on the probabilistic results. The random input variables are the material yield stress and internal pressure with Weibull and normal distributions, respectively. The results verify the ability of NESSUS to compute the CDF and sensitivity factors of a materially nonlinear structure. In addition, the ability of the Advanced Mean Value (AMV) procedure to assess the probabilistic behavior of structures which exhibit a highly nonlinear response is shown. Thus, the AMV procedure can be applied with confidence to other structures which exhibit nonlinear behavior.
Kondo, Yuki; Nurani, Alif Meem; Saito, Chieko; Ichihashi, Yasunori; Saito, Masato; Yamazaki, Kyoko; Mitsuda, Nobutaka; Ohme-Takagi, Masaru; Fukuda, Hiroo
2016-06-01
Cell differentiation is a complex process involving multiple steps, from initial cell fate specification to final differentiation. Procambial/cambial cells, which act as vascular stem cells, differentiate into both xylem and phloem cells during vascular development. Recent studies have identified regulatory cascades for xylem differentiation. However, the molecular mechanism underlying phloem differentiation is largely unexplored due to technical challenges. Here, we established an ectopic induction system for phloem differentiation named Vascular Cell Induction Culture System Using Arabidopsis Leaves (VISUAL). Our results verified similarities between VISUAL-induced Arabidopsis thaliana phloem cells and in vivo sieve elements. We performed network analysis using transcriptome data with VISUAL to dissect the processes underlying phloem differentiation, eventually identifying a factor involved in the regulation of the master transcription factor gene APL Thus, our culture system opens up new avenues not only for genetic studies of phloem differentiation, but also for future investigations of multidirectional differentiation from vascular stem cells. © 2016 American Society of Plant Biologists. All rights reserved.
NASA Technical Reports Server (NTRS)
Morris, Aaron L.; Olson, Leah M.
2011-01-01
The Crew Exploration Vehicle Parachute Assembly System (CPAS) is engaged in a multi-year design and test campaign aimed at qualifying a parachute recovery system for human use on the Orion Spacecraft. Orion has parachute flight performance requirements that will ultimately be verified through the use of Monte Carlo multi-degree of freedom flight simulations. These simulations will be anchored by real world flight test data and iteratively improved to provide a closer approximation to the real physics observed in the inherently chaotic inflation and steady state flight of the CPAS parachutes. This paper will examine the processes necessary to verify the flight performance requirements of the human rated spacecraft. The focus will be on the requirements verification and model validation planned on CPAS.
NASA Astrophysics Data System (ADS)
Nath, Nayani Kishore
2017-08-01
The throat back up liners is used to protect the nozzle structural members from the severe thermal environment in solid rocket nozzles. The throat back up liners is made with E-glass phenolic prepregs by tape winding process. The objective of this work is to demonstrate the optimization of process parameters of tape winding process to achieve better insulative resistance using Taguchi's robust design methodology. In this method four control factors machine speed, roller pressure, tape tension, tape temperature that were investigated for the tape winding process. The presented work was to study the cogency and acceptability of Taguchi's methodology in manufacturing of throat back up liners. The quality characteristic identified was Back wall temperature. Experiments carried out using L 9 ' (34) orthogonal array with three levels of four different control factors. The test results were analyzed using smaller the better criteria for Signal to Noise ratio in order to optimize the process. The experimental results were analyzed conformed and successfully used to achieve the minimum back wall temperature of the throat back up liners. The enhancement in performance of the throat back up liners was observed by carrying out the oxy-acetylene tests. The influence of back wall temperature on the performance of throat back up liners was verified by ground firing test.
Zhou, Dan; Cheng, Hongjing; Liu, Jinyu; Zhang, Lei
2017-06-01
Chronic liver disease has become a major health problem that causes serious damage to human health. Since the existing treatment effect was not ideal, we need to seek new treatment methods. We utilized the gene recombination technology to obtain the human hair mesenchymal stem cells which overexpression of human hepatocyte growth factor (hHGF). Furthermore, we verified the property of transfected cells through detecting surface marker by flow cytometry. We show here establishment of the hHGF-overexpressing lentivirus vector, and successfully transfection to human hair follicle mesenchymal stem cells. The verified experiments could demonstrate the human hair follicle mesenchymal stem cells which have been transfected still have the properties of stem cells. We successfully constructed human hair follicle mesenchymal stem cells which overexpression hHGF, and maintain the same properties compared with pro-transfected cells.
Pilot GPS LORAN Receiver Programming Performance A Laboratory Evaluation
DOT National Transportation Integrated Search
1994-02-01
This study was designed to explore GPS/LORAN receiver programming performance under : simulated flight conditions. The programming task consisted of entering, editing, and : verifying a four-waypoint flight plan. The task demands were manipulated by ...
Performance statistics of the FORTRAN 4 /H/ library for the IBM system/360
NASA Technical Reports Server (NTRS)
Clark, N. A.; Cody, W. J., Jr.; Hillstrom, K. E.; Thieleker, E. A.
1969-01-01
Test procedures and results for accuracy and timing tests of the basic IBM 360/50 FORTRAN 4 /H/ subroutine library are reported. The testing was undertaken to verify performance capability and as a prelude to providing some replacement routines of improved performance.
Linking Performance Measures to Resource Allocation: Exploring Unmapped Terrain.
ERIC Educational Resources Information Center
Ewell, Peter T.
1999-01-01
Examination of how (and whether) particular types of institutional performance measures can be beneficially used in making resource allocation decisions finds that only easily verifiable "hard" statistics should be used in classic performance funding approaches, although surveys and the use of good practices by institutions may…
Design and performance of daily quality assurance system for carbon ion therapy at NIRS
NASA Astrophysics Data System (ADS)
Saotome, N.; Furukawa, T.; Hara, Y.; Mizushima, K.; Tansho, R.; Saraya, Y.; Shirai, T.; Noda, K.
2017-09-01
At National Institute of Radiological Sciences (NIRS), we have been commissioning a rotating-gantry system for carbon-ion radiotherapy. This rotating gantry can transport heavy ions at 430 MeV/u to an isocenter with irradiation angles of ±180° that can rotate around the patient so that the tumor can be irradiated from any direction. A three-dimensional pencil-beam scanning irradiation system equipped with the rotating gantry enables the optimal use of physical characteristics of carbon ions to provide accurate treatment. To ensure the treatment quality using such a complex system, the calibration of the primary dose monitor, output check, range check, dose rate check, machine safety check, and some mechanical tests should be performed efficiently. For this purpose, we have developed a measurement system dedicated for quality assurance (QA) of this gantry system: the Daily QA system. The system consists of an ionization chamber system and a scintillator system. The ionization chamber system is used for the calibration of the primary dose monitor, output check, and dose rate check, and the scintillator system is used for the range check, isocenter, and gantry angle. The performance of the Daily QA system was verified by a beam test. The stability of the output was within 0.5%, and the range was within 0.5 mm. The coincidence of the coordinates between the patient-positioning system and the irradiation system was verified using the Daily QA system. Our present findings verified that the new Daily QA system for a rotating gantry is capable of verifying the irradiation system with sufficient accuracy.
Wu, Zhenkai; Ding, Jing; Zhao, Dahang; Zhao, Li; Li, Hai; Liu, Jianlin
2017-07-10
The multiplier method was introduced by Paley to calculate the timing for temporary hemiepiphysiodesis. However, this method has not been verified in terms of clinical outcome measure. We aimed to (1) predict the rate of angular correction per year (ACPY) at the various corresponding ages by means of multiplier method and verify the reliability based on the data from the published studies and (2) screen out risk factors for deviation of prediction. A comprehensive search was performed in the following electronic databases: Cochrane, PubMed, and EMBASE™. A total of 22 studies met the inclusion criteria. If the actual value of ACPY from the collected date was located out of the range of the predicted value based on the multiplier method, it was considered as the deviation of prediction (DOP). The associations of patient characteristics with DOP were assessed with the use of univariate logistic regression. Only one article was evaluated as moderate evidence; the remaining articles were evaluated as poor quality. The rate of DOP was 31.82%. In the detailed individual data of included studies, the rate of DOP was 55.44%. The multiplier method is not reliable in predicting the timing for temporary hemiepiphysiodesis, even though it is prone to be more reliable for the younger patients with idiopathic genu coronal deformity.
NASA Astrophysics Data System (ADS)
Fleischer, Christian; Waag, Wladislaw; Bai, Ziou; Sauer, Dirk Uwe
2013-12-01
The battery management system (BMS) of a battery-electric road vehicle must ensure an optimal operation of the electrochemical storage system to guarantee for durability and reliability. In particular, the BMS must provide precise information about the battery's state-of-functionality, i.e. how much dis-/charging power can the battery accept at current state and condition while at the same time preventing it from operating outside its safe operating area. These critical limits have to be calculated in a predictive manner, which serve as a significant input factor for the supervising vehicle energy management (VEM). The VEM must provide enough power to the vehicle's drivetrain for certain tasks and especially in critical driving situations. Therefore, this paper describes a new approach which can be used for state-of-available-power estimation with respect to lowest/highest cell voltage prediction using an adaptive neuro-fuzzy inference system (ANFIS). The estimated voltage for a given time frame in the future is directly compared with the actual voltage, verifying the effectiveness and accuracy of a relative voltage prediction error of less than 1%. Moreover, the real-time operating capability of the proposed algorithm was verified on a battery test bench while running on a real-time system performing voltage prediction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holmes, J.P.; Maxwell, R.L.; Wright, L.J.
A biometric identification device is an automatic device that can verify a person's identity from a measurement of a physical feature or repeatable action of the individual. A reference measurement of the biometric is obtained when the individual is enrolled on the device. Subsequent verifications are made by comparing the submitted biometric feature against the reference sample. Sandia Laboratories has been evaluating the relative performance of several identity verifiers, using volunteer test subjects. Sandia testing methods and results are discussed.
Zhao, Zhimiao; Song, Xinshan; Wang, Wei; Xiao, Yanping; Gong, Zhijie; Wang, Yuhui; Zhao, Yufeng; Chen, Yu; Mei, Mengyuan
2016-09-01
The influences of iron and calcium carbonate (CaCO3) addition in wastewater treatments reactors performance were investigated. Adding different concentrations of Fe(3+) (5, 10, 30 and 50mmol/m(3)), iron and CaCO3 powder led to changes in algal characteristics and physico-chemical and microbiological properties. According to the investigation results, nutrient removal efficiency in algae based reactors was obviously increased by the addition of 10mmol/m(3) Fe(3+), iron (5mmol/m(3)) and CaCO3 powder (0.2gm(-3)) and the removal efficiencies of BOD5, TN, and TP in Stage 2 were respectively increased by 28%, 8.9%, and 22%. The improvements in physico-chemical performances were verified by microbial community tests (bacteria quantity, activity and community measured in most probable number, extracellular enzymes activity, and Biolog Eco Plates). Microbial variations indicated the coexistence of Fe ions and carbonate-bicarbonate, which triggered the synergistic effect of physico-chemical action and microbial factors in algae based reactors. Copyright © 2016 Elsevier Ltd. All rights reserved.
Carbon Nanotube Self-Gating Diode and Application in Integrated Circuits.
Si, Jia; Liu, Lijun; Wang, Fanglin; Zhang, Zhiyong; Peng, Lian-Mao
2016-07-26
A nano self-gating diode (SGD) based on nanoscale semiconducting material is proposed, simulated, and realized on semiconducting carbon nanotubes (CNTs) through a doping-free fabrication process. The relationships between the performance and material/structural parameters of the SGD are explored through numerical simulation and verified by experiment results. Based on these results, performance optimization strategy is outlined, and high performance CNT SGDs are fabricated and demonstrated to surpass other published CNT diodes. In particular the CNT SGD exhibits high rectifier factor of up to 1.4 × 10(6) while retains large on-state current. Benefiting from high yield and stability, CNT SGDs are used for constructing logic and analog integrated circuits. Two kinds of basic digital gates (AND and OR) have been realized on chip through using CNT SGDs and on-chip Ti wire resistances, and a full wave rectifier circuit has been demonstrated through using two CNT SGDs. Although demonstrated here using CNT SGDs, this device structure may in principle be implemented using other semiconducting nanomaterials, to provide ideas and building blocks for electronic applications based on nanoscale materials.
2013-04-01
The main aims of the current research were to determine when children develop a temporally extended self (TES) and what factors contribute to its development. However, in order to address these aims it was important to, first, assess whether the test of delayed self-recognition (DSR) is a valid measure for the development of the TES, and, second, to propose and evaluate a theoretical model that describes what factors influence the development of the TES. The validity of the DSR test was verified by comparing the performance of 57 children on the DSR test to their performance on a meta-representational task (modified false belief task) and to a task that was essentially the same as the DSR test but was specifically designed to rely on the capacity to entertain secondary representations (i.e., surprise body task). Longitudinal testing of the children showed that at the mental age (MA) of 2.5 years they failed the DSR test, despite training them to understand the intended functions of the medium used in the DSR test; whereas, with training, children at the MA of 3.0 and 3.5 years exhibited DSR. Children at the MA of 4 years exhibited DSR without any training. Finally, results suggest that children's meta-representational ability was the only factor that contributed to the prediction of successful performance on the DSR test, and thus to the emergence of the TES. Furthermore, prospective longitudinal data revealed that caregiver conversational style was the only factor that contributed to the prediction of level of training required to pass the DSR test. That is, children of low-elaborative caregivers required significantly more training to pass the DSR test than children of high-elaborative caregivers, indicating that children who received more elaborative conversational input from their caregivers had a more advanced understanding of their TES. © 2013 The Society for Research in Child Development, Inc.
40 CFR 230.95 - Ecological performance standards.
Code of Federal Regulations, 2012 CFR
2012-07-01
... mitigation plan must contain performance standards that will be used to assess whether the project is... mitigation project, so that the project can be objectively evaluated to determine if it is developing into... verifiable. Ecological performance standards must be based on the best available science that can be measured...
40 CFR 230.95 - Ecological performance standards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... mitigation plan must contain performance standards that will be used to assess whether the project is... mitigation project, so that the project can be objectively evaluated to determine if it is developing into... verifiable. Ecological performance standards must be based on the best available science that can be measured...
40 CFR 230.95 - Ecological performance standards.
Code of Federal Regulations, 2013 CFR
2013-07-01
... mitigation plan must contain performance standards that will be used to assess whether the project is... mitigation project, so that the project can be objectively evaluated to determine if it is developing into... verifiable. Ecological performance standards must be based on the best available science that can be measured...
40 CFR 230.95 - Ecological performance standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... mitigation plan must contain performance standards that will be used to assess whether the project is... mitigation project, so that the project can be objectively evaluated to determine if it is developing into... verifiable. Ecological performance standards must be based on the best available science that can be measured...
VERIFYING THE VOC CONTROL PERFORMANCE OF BIOREACTORS
The paper describes the verification testing approach used to collect high-quality, peer-reviewed data on the performance of bioreaction-based technologies for the control of volatile organic compounds (VOCs). The verification protocol that describes the approach for these tests ...
SIMS prototype system 4 - performance test report
NASA Technical Reports Server (NTRS)
1978-01-01
A self-contained, preassembled air type solar system, designed for installation remote from the dwelling, to provide space heating and hot water was evaluated. Data analysis is included which documents the system performance and verifies its suitability for field installation.
NASA Astrophysics Data System (ADS)
Mastropasqua, L.; Campanari, S.; Brouwer, J.
2017-12-01
The need to experimentally understand the detailed performance of SOFC stacks under operating conditions typical of commercial SOFC systems has prompted this two-part study. The steady state performance of a 6-cell short stack of yttria (Y2O3) stabilised zirconia (YSZ) with Ni/YSZ anodes and composite Sr-doped lanthanum manganite (LaMnO3, LSM)/YSZ cathodes is experimentally evaluated. In Part A, the stack characterisation is carried out by means of sensitivity analyses on the fuel utilisation factor and the steam-to-carbon ratio. Electrical and environmental performances are assessed and the results are compared with a commercial full-scale micro-CHP system, which comprises the same cells. The results show that the measured temperature dynamics of the short stack in a test stand environment are on the order of many minutes; therefore, one cannot neglect temperature dynamics for a precise measurement of the steady state polarisation behaviour. The overall polarisation performance is comparable to that of the full stack employed in the micro-CHP system, confirming the good representation that short-stack analyses can give of the entire SOFC module. The environmental performance is measured verifying the negligible values of NO emissions (<10 ppb) across the whole polarisation curve.
Performance Evaluation and Requirements Assessment for Gravity Gradient Referenced Navigation
Lee, Jisun; Kwon, Jay Hyoun; Yu, Myeongjong
2015-01-01
In this study, simulation tests for gravity gradient referenced navigation (GGRN) are conducted to verify the effects of various factors such as database (DB) and sensor errors, flight altitude, DB resolution, initial errors, and measurement update rates on the navigation performance. Based on the simulation results, requirements for GGRN are established for position determination with certain target accuracies. It is found that DB and sensor errors and flight altitude have strong effects on the navigation performance. In particular, a DB and sensor with accuracies of 0.1 E and 0.01 E, respectively, are required to determine the position more accurately than or at a level similar to the navigation performance of terrain referenced navigation (TRN). In most cases, the horizontal position error of GGRN is less than 100 m. However, the navigation performance of GGRN is similar to or worse than that of a pure inertial navigation system when the DB and sensor errors are 3 E or 5 E each and the flight altitude is 3000 m. Considering that the accuracy of currently available gradiometers is about 3 E or 5 E, GGRN does not show much advantage over TRN at present. However, GGRN is expected to exhibit much better performance in the near future when accurate DBs and gravity gradiometer are available. PMID:26184212
Park, Sung Hwan; Lee, Ji Min; Kim, Jong Shik
2013-01-01
An irregular performance of a mechanical-type constant power regulator is considered. In order to find the cause of an irregular discharge flow at the cut-off pressure area, modeling and numerical simulations are performed to observe dynamic behavior of internal parts of the constant power regulator system for a swashplate-type axial piston pump. The commercial numerical simulation software AMESim is applied to model the mechanical-type regulator with hydraulic pump and simulate the performance of it. The validity of the simulation model of the constant power regulator system is verified by comparing simulation results with experiments. In order to find the cause of the irregular performance of the mechanical-type constant power regulator system, the behavior of main components such as the spool, sleeve, and counterbalance piston is investigated using computer simulation. The shape modification of the counterbalance piston is proposed to improve the undesirable performance of the mechanical-type constant power regulator. The performance improvement is verified by computer simulation using AMESim software. PMID:24282389
NASA Technical Reports Server (NTRS)
Laible, Michael R.
2011-01-01
The Microgravity performance assessment of the International Space Station (ISS) is comprised of a quasi-steady, structural dynamic and a vibro-acoustic analysis of the ISS assembly-complete vehicle configuration. The Boeing Houston (BHOU) Loads and Dynamics Team is responsible to verify compliance with the ISS System Specification (SSP 41000) and USOS Segment (SSP 41162) microgravity requirements. To verify the ISS environment, a series of accelerometers are on-board to monitor the current environment. This paper summarizes the results of the analysis that was performed for the Verification Analysis Cycle (VAC)-Assembly Complete (AC) and compares it to on-orbit acceleration values currently being reported. The analysis will include the predicted maximum and average environment on-board ISS during multiple activity scenarios
Automatic reactor control system for transient operation
NASA Astrophysics Data System (ADS)
Lipinski, Walter C.; Bhattacharyya, Samit K.; Hanan, Nelson A.
Various programmatic considerations have delayed the upgrading of the TREAT reactor and the performance of the control system is not yet experimentally verified. The current schedule calls for the upgrading activities to occur last in the calendar year 1987. Detailed simulation results, coupled with earlier validation of individual components of the control strategy in TREAT, verify the performance of the algorithms. The control system operates within the safety envelope provided by a protection system designed to ensure reactor safety under conditions of spurious reactivity additions. The approach should be directly applicable to MMW systems, with appropriate accounting of temperature rate limitations of key components and of the inertia of the secondary system components.
Validation and Utility of the Social Emotional Health Survey-Secondary for Japanese Students
ERIC Educational Resources Information Center
Ito, Ayako; Smith, Douglas C.; You, Sukkyung; Shimoda, Yoshiyuki; Furlong, Michael J.
2015-01-01
The article explores the use of the Social and Emotional Health Survey-Secondary version (SEHS-S) with a sample of 975 Japanese students in Grades 7-9 attending schools located northwest of Tokyo. A confirmatory factor analysis using half the sample confirmed the four-factor structure of the SEHS-S, and further analyses verified its second-order…
1989-05-01
also drawn up by Vereinigte Flugtech- nischen Werken as a technoeconomic analysis . The aerospace industry will be looking for the following...ultimate load without rupture. These conditions are verified by analysis and test. The limit load is the maximum load the vehicle is expected to see...the uncertainty factor (formerly known as the factor of safety) which accounts for variations in manufacture, defects not assumed in analysis but
Development and validation of a stock addiction inventory (SAI).
Youn, HyunChul; Choi, Jung-Seok; Kim, Dai-Jin; Choi, Sam-Wook
2016-01-01
Investing in financial markets is promoted and protected by the government as an essential economic activity, but can turn into a gambling addiction problem. Until now, few scales have widely been used to identify gambling addicts in financial markets. This study aimed to develop a self-rating scale to distinguish them. In addition, the reliability and validity of the stock addiction inventory (SAI) were demonstrated. A set of questionnaires, including the SAI, south oaks gambling screen (SOGS), and DSM-5 diagnostic criteria, for gambling disorder was completed by 1005 participants. Factor analysis, internal consistency testing, t tests, analysis of variance, and partial correlation analysis were conducted to verify the reliability and validity of SAI. The factor analysis results showed the final SAI consisting of two factors and nine items. The internal consistency and concurrent validity of SAI were verified. The Cronbach's α for the total scale was 0.892, and the SAI and its factors were significantly correlated with SOGS. This study developed a specific scale for financial market investments or trading; this scale proved to be reliable and valid. Our scale expands the understanding of gambling addiction in financial markets and provides a diagnostic reference.
NASA-STD 3001 and the Human Integration Design Handbook (HIDH): Evolution of NASA-STD-3000
NASA Technical Reports Server (NTRS)
Pickett, Lynn; Connolly, Janis; Arch, M.; Tillman, Barry; Russo, Dane
2007-01-01
The Habitability & Environmental Factors and Space Medicine Divisions have developed the Space Flight Human System Standard (SFHSS) (NASA-STD-3001) to replace NASA-STD-3000 as a new NASA standard for all human spaceflight programs. The SFHSS is composed of 2 volumes. Volume 1, Crew Health, contains medical levels of care, permissible exposure limits, and fitness for duty criteria, and permissible outcome limits as a means of defining successful operating criteria for the human system. Volume 2, Habitability and Environmental Health, contains environmental, habitability and human factors standards. Development of the Human Integration Design Handbook (HIDH), a companion to the standard, is currently under construction and entails the update and revision of NASA-STD-3000 data. This new handbook will, in the fashion of NASA STD-3000, assist engineers and designers in appropriately applying habitability, environmental and human factors principles to spacecraft design. Organized in a chapter-module-element structure, the HIDH will provide the guidance for the development of requirements, design considerations, lessons learned, example solutions, background research, and assist in the identification of gaps and research needs in the disciplines. Subject matter experts have been and continue to be solicited to participate in the update of the chapters. The purpose is to build the HIDH with the best and latest data, and provide a broad representation from experts in industry, academia, the military and the space program. The handbook and the two standards volumes work together in a unique way to achieve the required level of human-system interface. All new NASA programs will be required to meet Volumes 1 and 2. Volume 2 presents human interface goals in broad, non-verifiable standards. Volume 2 also requires that each new development program prepare a set of program-specific human factors requirements. These program-specific human and environmental factors requirements must be verifiable and tailored to assure the new system meets the Volume 2 standards. Programs will use the HIDH to write their verifiable program-specific requirements.
Stress Free Temperature Testing and Residual Stress Calculations on Out-of-Autoclave Composites
NASA Technical Reports Server (NTRS)
Cox, Sarah; Tate, LaNetra C.; Danley, Susan; Sampson, Jeff; Taylor, Brian; Miller, Sandi
2012-01-01
Future launch vehicles will require the incorporation large composite parts that will make up primary and secondary components of the vehicle. NASA has explored the feasibility of manufacturing these large components using Out-of-Autoclave impregnated carbon fiber composite systems through many composites development projects. Most recently, the Composites for Exploration Project has been looking at the development of a 10 meter diameter fairing structure, similar in size to what will be required for a heavy launch vehicle. The development of new material systems requires the investigation of the material properties and the stress in the parts. Residual stress is an important factor to incorporate when modeling the stresses that a part is undergoing. Testing was performed to verify the stress free temperature with two-ply asymmetric panels. A comparison was done between three newly developed out of autoclave IM7 /Bismalieimide (BMI) systems. This paper presents the testing results and the analysis performed to determine the residual stress of the materials.
Stress Free Temperature Testing and Calculations on Out-of-Autoclave Composites
NASA Technical Reports Server (NTRS)
Cox, Sarah B.; Tate, LeNetra C.; Danley, Susan E.; Sampson, Jeffrey W.; Taylor, Brian J.; Sutter, James K.; Miller, Sandi G.
2013-01-01
Future launch vehicles will require the incorporation of large composite parts that will make up primary and secondary components of the vehicle. NASA has explored the feasibility of manufacturing these large components using Out-of-Autoclave impregnated carbon fiber composite systems through many composites development projects. Most recently, the Composites for Exploration Project has been looking at the development of a 10 meter diameter fairing structure, similar in size to what will be required for a heavy launch vehicle. The development of new material systems requires the investigation of the material properties and the stress in the parts. Residual stress is an important factor to incorporate when modeling the stresses that a part is undergoing. Testing was performed to verify the stress free temperature with two-ply asymmetric panels. A comparison was done between three newly developed out of autoclave IM7/Bismaleimide (BMI) systems. This paper presents the testing results and the analysis performed to determine the stress free temperature of the materials
Probability-based collaborative filtering model for predicting gene-disease associations.
Zeng, Xiangxiang; Ding, Ningxiang; Rodríguez-Patón, Alfonso; Zou, Quan
2017-12-28
Accurately predicting pathogenic human genes has been challenging in recent research. Considering extensive gene-disease data verified by biological experiments, we can apply computational methods to perform accurate predictions with reduced time and expenses. We propose a probability-based collaborative filtering model (PCFM) to predict pathogenic human genes. Several kinds of data sets, containing data of humans and data of other nonhuman species, are integrated in our model. Firstly, on the basis of a typical latent factorization model, we propose model I with an average heterogeneous regularization. Secondly, we develop modified model II with personal heterogeneous regularization to enhance the accuracy of aforementioned models. In this model, vector space similarity or Pearson correlation coefficient metrics and data on related species are also used. We compared the results of PCFM with the results of four state-of-arts approaches. The results show that PCFM performs better than other advanced approaches. PCFM model can be leveraged for predictions of disease genes, especially for new human genes or diseases with no known relationships.
Process performance of high-solids batch anaerobic digestion of sewage sludge.
Liao, Xiaocong; Li, Huan; Cheng, Yingchao; Chen, Nan; Li, Chenchen; Yang, Yuning
2014-01-01
The characteristics of high-solids anaerobic digestion (AD) of sewage sludge were investigated by comparison with conventional low-solids processes. A series of batch experiments were conducted under mesophilic condition and the initial solid contents were controlled at four levels of 1.79%, 4.47%, 10.28% and 15.67%. During these experiments, biogas production, organic degradation and intermediate products were monitored. The results verified that high-solids batch AD of sewage sludge was feasible. Compared with the low-solids AD with solid contents of 1.79% or 4.47%, the high-solids processes decreased the specific biogas yield per gram of sludge volatile solids slightly, achieved the same organic degradation rate of about 40% within extended degradation time, but increased the volumetric biogas production rate and the treatment capability of digesters significantly. The blocked mass and energy transfer, the low substrate to inoculum rate and the excessive cumulative free ammonia were the main factors impacting the performance of high-solids batch AD.
NASA Astrophysics Data System (ADS)
Seo, In-jin; Choi, Won; Seong, Jae-gyu; Lee, Bang-wook; Koo, Ja-yoon
2014-08-01
It has been reported that the insulation design under DC stress is considered as one of the critical factors in determining the performance of high-voltage direct current (HVDC) superconducting cable. Therefore, it is fundamentally necessary to investigate the DC breakdown characteristics of the composite insulation system consisting of liquid nitrogen (LN2)/polypropylene-laminated-paper (PPLP). In particular, the insulation characteristics under DC polarity reversal condition should be verified to understand the polarity effect of the DC voltage considering the unexpected incidents taking place at line-commutated-converters (LCC) under service at a DC power grid. In this study, to examine the variation of DC electric field strength, the step voltage and polarity reversal breakdown tests are performed under DC stress. Also, we investigate the electric field distributions in a butt gap of the LN2/PPLP condition considering the DC polarity reversal by using simulation software.
Jiang, Haojun; Xie, Yifan; Li, Xuchao; Ge, Huijuan; Deng, Yongqiang; Mu, Haofang; Feng, Xiaoli; Yin, Lu; Du, Zhou; Chen, Fang; He, Nongyue
2016-01-01
Short tandem repeats (STRs) and single nucleotide polymorphisms (SNPs) have been already used to perform noninvasive prenatal paternity testing from maternal plasma DNA. The frequently used technologies were PCR followed by capillary electrophoresis and SNP typing array, respectively. Here, we developed a noninvasive prenatal paternity testing (NIPAT) based on SNP typing with maternal plasma DNA sequencing. We evaluated the influence factors (minor allele frequency (MAF), the number of total SNP, fetal fraction and effective sequencing depth) and designed three different selective SNP panels in order to verify the performance in clinical cases. Combining targeted deep sequencing of selective SNP and informative bioinformatics pipeline, we calculated the combined paternity index (CPI) of 17 cases to determine paternity. Sequencing-based NIPAT results fully agreed with invasive prenatal paternity test using STR multiplex system. Our study here proved that the maternal plasma DNA sequencing-based technology is feasible and accurate in determining paternity, which may provide an alternative in forensic application in the future.
One way Doppler extractor. Volume 1: Vernier technique
NASA Technical Reports Server (NTRS)
Blasco, R. W.; Klein, S.; Nossen, E. J.; Starner, E. R.; Yanosov, J. A.
1974-01-01
A feasibility analysis, trade-offs, and implementation for a One Way Doppler Extraction system are discussed. A Doppler error analysis shows that quantization error is a primary source of Doppler measurement error. Several competing extraction techniques are compared and a Vernier technique is developed which obtains high Doppler resolution with low speed logic. Parameter trade-offs and sensitivities for the Vernier technique are analyzed, leading to a hardware design configuration. A detailed design, operation, and performance evaluation of the resulting breadboard model is presented which verifies the theoretical performance predictions. Performance tests have verified that the breadboard is capable of extracting Doppler, on an S-band signal, to an accuracy of less than 0.02 Hertz for a one second averaging period. This corresponds to a range rate error of no more than 3 millimeters per second.
ERIC Educational Resources Information Center
Szilagyi, Andrew D.
1977-01-01
Attempts to empirically verify the causal source and direction of causal influence between role ambiguity, role conflict and job satisfaction and performance for three organizational levels in a hospital environment. (Author/RK)
EPA GROUP VERIFIES PERFORMANCE OF GREENHOUSE GAS EMISSIONS-MITIGATION TECHNOLOGIES
The Greenhouse Gas Technology Verification Center (the Center) is one of 12 independently operated environmental technology verification organizations established by the U.S. Environmental Protection Agency (EPA). The Center provides third-party performance data to industry and o...
D'Astolfo, Diego S.; Cardoso, Fernanda C.; Rajão, Matheus A.; Mourão, Marina M.; Gava, Elisandra; Oliveira, Sérgio C.; Macedo, Andréa M.; Machado, Carlos R.; Pena, Sérgio D. J.; Kitten, Gregory T.; Franco, Glória R.
2009-01-01
Background During its development, the parasite Schistosoma mansoni is exposed to different environments and undergoes many morphological and physiological transformations as a result of profound changes in gene expression. Characterization of proteins involved in the regulation of these processes is of importance for the understanding of schistosome biology. Proteins containing zinc finger motifs usually participate in regulatory processes and are considered the major class of transcription factors in eukaryotes. It has already been shown, by EMSA (Eletrophoretic Mobility Shift Assay), that SmZF1, a S. mansoni zinc finger (ZF) protein, specifically binds both DNA and RNA oligonucleotides. This suggests that this protein might act as a transcription factor in the parasite. Methodology/Principal Findings In this study we extended the characterization of SmZF1 by determining its subcellular localization and by verifying its ability to regulate gene transcription. We performed immunohistochemistry assays using adult male and female worms, cercariae and schistosomula to analyze the distribution pattern of SmZF1 and verified that the protein is mainly detected in the cells nuclei of all tested life cycle stages except for adult female worms. Also, SmZF1 was heterologously expressed in mammalian COS-7 cells to produce the recombinant protein YFP-SmZF1, which was mainly detected in the nucleus of the cells by confocal microscopy and Western blot assays. To evaluate the ability of this protein to regulate gene transcription, cells expressing YFP-SmZF1 were tested in a luciferase reporter system. In this system, the luciferase gene is downstream of a minimal promoter, upstream of which a DNA region containing four copies of the SmZF1 putative best binding site (D1-3DNA) was inserted. SmZF1 increased the reporter gene transcription by two fold (p≤0.003) only when its specific binding site was present. Conclusion Taken together, these results strongly support the hypothesis that SmZF1 acts as a transcription factor in S. mansoni. PMID:19901992
Kerns, James R; Followill, David S; Lowenstein, Jessica; Molineu, Andrea; Alvarez, Paola; Taylor, Paige A; Stingo, Francesco C; Kry, Stephen F
2016-05-01
Accurate data regarding linear accelerator (Linac) radiation characteristics are important for treatment planning system modeling as well as regular quality assurance of the machine. The Imaging and Radiation Oncology Core-Houston (IROC-H) has measured the dosimetric characteristics of numerous machines through their on-site dosimetry review protocols. Photon data are presented and can be used as a secondary check of acquired values, as a means to verify commissioning a new machine, or in preparation for an IROC-H site visit. Photon data from IROC-H on-site reviews from 2000 to 2014 were compiled and analyzed. Specifically, data from approximately 500 Varian machines were analyzed. Each dataset consisted of point measurements of several dosimetric parameters at various locations in a water phantom to assess the percentage depth dose, jaw output factors, multileaf collimator small field output factors, off-axis factors, and wedge factors. The data were analyzed by energy and parameter, with similarly performing machine models being assimilated into classes. Common statistical metrics are presented for each machine class. Measurement data were compared against other reference data where applicable. Distributions of the parameter data were shown to be robust and derive from a student's t distribution. Based on statistical and clinical criteria, all machine models were able to be classified into two or three classes for each energy, except for 6 MV for which there were eight classes. Quantitative analysis of the measurements for 6, 10, 15, and 18 MV photon beams is presented for each parameter; supplementary material has also been made available which contains further statistical information. IROC-H has collected numerous data on Varian Linacs and the results of photon measurements from the past 15 years are presented. The data can be used as a comparison check of a physicist's acquired values. Acquired values that are well outside the expected distribution should be verified by the physicist to identify whether the measurements are valid. Comparison of values to this reference data provides a redundant check to help prevent gross dosimetric treatment errors.
Gaia challenging performances verification: combination of spacecraft models and test results
NASA Astrophysics Data System (ADS)
Ecale, Eric; Faye, Frédéric; Chassat, François
2016-08-01
To achieve the ambitious scientific objectives of the Gaia mission, extremely stringent performance requirements have been given to the spacecraft contractor (Airbus Defence and Space). For a set of those key-performance requirements (e.g. end-of-mission parallax, maximum detectable magnitude, maximum sky density or attitude control system stability), this paper describes how they are engineered during the whole spacecraft development process, with a focus on the end-to-end performance verification. As far as possible, performances are usually verified by end-to-end tests onground (i.e. before launch). However, the challenging Gaia requirements are not verifiable by such a strategy, principally because no test facility exists to reproduce the expected flight conditions. The Gaia performance verification strategy is therefore based on a mix between analyses (based on spacecraft models) and tests (used to directly feed the models or to correlate them). Emphasis is placed on how to maximize the test contribution to performance verification while keeping the test feasible within an affordable effort. In particular, the paper highlights the contribution of the Gaia Payload Module Thermal Vacuum test to the performance verification before launch. Eventually, an overview of the in-flight payload calibration and in-flight performance verification is provided.
Krompecher, T; Bergerioux, C; Brandt-Casadevall, C; Gujer, H R
1983-07-01
The evolution of rigor mortis was studied in cases of nitrogen asphyxia, drowning and strangulation, as well as in fatal intoxications due to strychnine, carbon monoxide and curariform drugs, using a modified method of measurement. Our experiments demonstrated that: (1) Strychnine intoxication hastens the onset and passing of rigor mortis. (2) CO intoxication delays the resolution of rigor mortis. (3) The intensity of rigor may vary depending upon the cause of death. (4) If the stage of rigidity is to be used to estimate the time of death, it is necessary: (a) to perform a succession of objective measurements of rigor mortis intensity; and (b) to verify the eventual presence of factors that could play a role in the modification of its development.
NASA Astrophysics Data System (ADS)
Lu, Jiazhen; Yang, Lie
2018-05-01
To achieve accurate and completely autonomous navigation for spacecraft, inertial/celestial integrated navigation gets increasing attention. In this study, a missile-borne inertial/stellar refraction integrated navigation scheme is proposed. Position Dilution of Precision (PDOP) for stellar refraction is introduced and the corresponding equation is derived. Based on the condition when PDOP reaches the minimum value, an optimized observation scheme is proposed. To verify the feasibility of the proposed scheme, numerical simulation is conducted. The results of the Extended Kalman Filter (EKF) and Unscented Kalman Filter (UKF) are compared and impact factors of navigation accuracy are studied in the simulation. The simulation results indicated that the proposed observation scheme has an accurate positioning performance, and the results of EKF and UKF are similar.
NASA Astrophysics Data System (ADS)
Nguyen, Dung Xuan; Gromov, Andrey; Son, Dam Thanh
2018-05-01
We perform a detailed comparison of the Dirac composite fermion and the recently proposed bimetric theory for a quantum Hall Jain states near half filling. By tuning the composite Fermi liquid to the vicinity of a nematic phase transition, we find that the two theories are equivalent to each other. We verify that the single mode approximation for the response functions and the static structure factor becomes reliable near the phase transition. We show that the dispersion relation of the nematic mode near the phase transition can be obtained from the Dirac brackets between the components of the nematic order parameter. The dispersion is quadratic at low momenta and has a magnetoroton minimum at a finite momentum, which is not related to any nearby inhomogeneous phase.
NASA Astrophysics Data System (ADS)
Tang, Tao; Cai, Huaxiang; Huang, Yongmei; Ren, Ge
2015-10-01
A feedforward control based on data fusion is proposed to enhance closed-loop performance. The target trajectory as the observed value of a Kalman filter is recovered by synthesizing line-of-sight error and angular position from the encoder. A Kalman filter based on a Singer acceleration model is employed to estimate the target velocity. In this control scheme, the control stability is influenced by the bandwidth of the Kalman filter and time misalignment. The transfer function of the Kalman filter in the frequency domain is built for analyzing the closed loop stability, which shows that the Kalman filter is the major factor that affects the control stability. The feedforward control proposed here is verified through simulations and experiments.
Signal-to-noise ratio of Singer product apertures
NASA Astrophysics Data System (ADS)
Shutler, Paul M. E.; Byard, Kevin
2017-09-01
Formulae for the signal-to-noise ratio (SNR) of Singer product apertures are derived, allowing optimal Singer product apertures to be identified, and the CPU time required to decode them is quantified. This allows a systematic comparison to be made of the performance of Singer product apertures against both conventionally wrapped Singer apertures, and also conventional product apertures such as square uniformly redundant arrays. For very large images, equivalently for images at very high resolution, the SNR of Singer product apertures is asymptotically as good as the best conventional apertures, but Singer product apertures decode faster than any conventional aperture by at least a factor of ten for image sizes up to several megapixels. These theoretical predictions are verified using numerical simulations, demonstrating that coded aperture video is for the first time a realistic possibility.
Lu, Jiazhen; Yang, Lie
2018-05-01
To achieve accurate and completely autonomous navigation for spacecraft, inertial/celestial integrated navigation gets increasing attention. In this study, a missile-borne inertial/stellar refraction integrated navigation scheme is proposed. Position Dilution of Precision (PDOP) for stellar refraction is introduced and the corresponding equation is derived. Based on the condition when PDOP reaches the minimum value, an optimized observation scheme is proposed. To verify the feasibility of the proposed scheme, numerical simulation is conducted. The results of the Extended Kalman Filter (EKF) and Unscented Kalman Filter (UKF) are compared and impact factors of navigation accuracy are studied in the simulation. The simulation results indicated that the proposed observation scheme has an accurate positioning performance, and the results of EKF and UKF are similar.
NASA Technical Reports Server (NTRS)
Paul, Heather L.; Jennings, Mallory A.
2009-01-01
The Trace Contaminant Control System (TCCS), located within the ventilation loop of the Portable Life Support System (PLSS) of the Constellation Space Suit Element (CSSE), is responsible for removing hazardous trace contaminants from the space suit ventilation flow. This paper summarizes the results of a trade study that evaluated if trace contaminant control could be accomplished without a TCCS, relying on suit leakage, ullage loss from the carbon dioxide and humidity control system, and other factors. Trace contaminant generation rates were revisited to verify that values reflect the latest designs for CSSE pressure garment materials and PLSS hardware. Additionally, TCCS sizing calculations were performed and a literature survey was conducted to review the latest developments in trace contaminant technologies.
Rzezak, Patricia; Guimarães, Catarina A; Guerreiro, Marilisa M; Valente, Kette D
2017-05-01
Patients with TLE are prone to have lower IQ scores than healthy controls. Nevertheless, the impact of IQ differences is not usually considered in studies that compared the cognitive functioning of children with and without epilepsy. This study aimed to determine the effect of using IQ as a covariate on memory and attentional/executive functions of children with TLE. Thirty-eight children and adolescents with TLE and 28 healthy controls paired as to age, gender, and sociodemographic factors were evaluated with a comprehensive neuropsychological battery for memory and executive functions. The authors conducted three analyses to verify the impact of IQ scores on the other cognitive domains. First, we compared performance on cognitive tests without controlling for IQ differences between groups. Second, we performed the same analyses, but we included IQ as a confounding factor. Finally, we evaluated the predictive value of IQ on cognitive functioning. Although patients had IQ score in the normal range, they showed lower IQ scores than controls (p = 0.001). When we did not consider IQ in the analyses, patients had worse performance in verbal and visual memory (short and long-term), semantic memory, sustained, divided and selective attention, mental flexibility and mental tracking for semantic information. By using IQ as a covariate, patients showed worse performance only in verbal memory (long-term), semantic memory, sustained and divided attention and in mental flexibility. IQ was a predictor factor of verbal and visual memory (immediate and delayed), working memory, mental flexibility and mental tracking for semantic information. Intelligence level had a significant impact on memory and executive functioning of children and adolescents with TLE without intellectual disability. This finding opens the discussion of whether IQ scores should be considered when interpreting the results of differences in cognitive performance of patients with epilepsy compared to healthy volunteers. Copyright © 2017 European Paediatric Neurology Society. Published by Elsevier Ltd. All rights reserved.
Deciding Full Branching Time Logic by Program Transformation
NASA Astrophysics Data System (ADS)
Pettorossi, Alberto; Proietti, Maurizio; Senni, Valerio
We present a method based on logic program transformation, for verifying Computation Tree Logic (CTL*) properties of finite state reactive systems. The finite state systems and the CTL* properties we want to verify, are encoded as logic programs on infinite lists. Our verification method consists of two steps. In the first step we transform the logic program that encodes the given system and the given property, into a monadic ω -program, that is, a stratified program defining nullary or unary predicates on infinite lists. This transformation is performed by applying unfold/fold rules that preserve the perfect model of the initial program. In the second step we verify the property of interest by using a proof method for monadic ω-programs.
Estimation of sample size and testing power (Part 3).
Hu, Liang-ping; Bao, Xiao-lei; Guan, Xue; Zhou, Shi-guo
2011-12-01
This article introduces the definition and sample size estimation of three special tests (namely, non-inferiority test, equivalence test and superiority test) for qualitative data with the design of one factor with two levels having a binary response variable. Non-inferiority test refers to the research design of which the objective is to verify that the efficacy of the experimental drug is not clinically inferior to that of the positive control drug. Equivalence test refers to the research design of which the objective is to verify that the experimental drug and the control drug have clinically equivalent efficacy. Superiority test refers to the research design of which the objective is to verify that the efficacy of the experimental drug is clinically superior to that of the control drug. By specific examples, this article introduces formulas of sample size estimation for the three special tests, and their SAS realization in detail.
Weighted Global Artificial Bee Colony Algorithm Makes Gas Sensor Deployment Efficient
Jiang, Ye; He, Ziqing; Li, Yanhai; Xu, Zhengyi; Wei, Jianming
2016-01-01
This paper proposes an improved artificial bee colony algorithm named Weighted Global ABC (WGABC) algorithm, which is designed to improve the convergence speed in the search stage of solution search equation. The new method not only considers the effect of global factors on the convergence speed in the search phase, but also provides the expression of global factor weights. Experiment on benchmark functions proved that the algorithm can improve the convergence speed greatly. We arrive at the gas diffusion concentration based on the theory of CFD and then simulate the gas diffusion model with the influence of buildings based on the algorithm. Simulation verified the effectiveness of the WGABC algorithm in improving the convergence speed in optimal deployment scheme of gas sensors. Finally, it is verified that the optimal deployment method based on WGABC algorithm can improve the monitoring efficiency of sensors greatly as compared with the conventional deployment methods. PMID:27322262
Martins, Andréa Maria Eleutério de Barros Lima; da Costa, Fernanda Marques; Ferreira, Raquel Conceição; dos Santos Neto, Pedro Eleutério; de Magalhaes, Tatiana Almeida; de Sá, Maria Aparecida Barbosa; Pordeus, Isabela Almeida
2015-01-01
Cross-sectional study conducted among workers of the Family Health Strategy Montes Claros. To investigate the report of vaccination against Hepatitis B, verification of immunization and the factors associated with dosages of anti-HBs. We collected blood samples from those reported that they had one or more doses of the vaccine. We evaluated the association of the dosage of anti- HBs with sociodemographic conditions, occupational and behavioral. The associations were verified by Mann Whitney and Kruskal Wallis and correlation Spermann by linear regression using SPSS® 17.0. Among the 761 respondents, 504 (66.1%) were vaccinated, 52.5 % received three doses, 30.4 % verified immunization. Of the 397 evaluated for the determination of anti-Hbs, 16.4% were immune. It was found that longer duration of work was associated with higher levels of anti-HBs, while levels of smoking were inversely associated with anti-HBs. These workers need for vaccination campaigns.
Guo, Li-Hua; Zhao, Wei; Zhang, Jun-Jie; Zhang, Qian; Fan, Ying-Zhong; Wang, Jia-Xiang
2016-12-01
To screen and identify serum biomarkers for childhood hepatoblastoma (HB). The serum samples from 30 children with hepatoblastoma (HB), 20 children with systemic inflammatory response syndrome, and 20 normal children were treated with magnetic bead-based weak cation exchange chromatography. The platform of surface-enhanced laser desorption/ionization-time of flight-mass spectrometry (SELDI-TOF-MS) was used to eliminate the interference of inflammatory factors and to screen out the differentially expressed proteins in serum between tumor group and normal group. After the purification and separation of target proteins were performed using sodium dodecyl sulfate-polyacrylamide gel electrophoresis, matrix-assisted laser desorption/ionization-time of flight-mass spectrometry was used to determine their amino acid sequences. The SwissProt database was searched for matched proteins. Finally, real-time PCR and ELISA were used to verify and measure the expression of target proteins. After SELDI-TOF-MS was used for screening and elimination of the interference of inflammatory factors, a differentially expression protein with a mass-to-charge ratio of 9 348 Da was found in serum between HB group and normal group, and the HB group had significantly lower expression of this protein than the normal group (p<0.05). This protein was identified as apolipoprotein A-1 (Apo A-I). Real-time PCR and ELISA verified the low mRNA and protein expression of Apo A-I in serum in the HB group and high expression in serum in the normal group. Apo A-I can be used as a non-inflammatory protein marker for HB and has a certain value in the early diagnosis of HB.
Association between Caesarean Delivery and Isolated Doses of Formula Feeding in Cow Milk Allergy.
Gil, Francisco; Amezqueta, Ana; Martinez, Diana; Aznal, Elena; Etayo, Veronica; Durá, Teodoro; Sánchez-Valverde, Félix
2017-01-01
Cow milk allergy (CMA) is the most common food allergy in breastfed infants. The aim of this study is to verify whether certain perinatal factors may influence the development of CMA immunoglobulin E (IgE)+. A retrospective, observational study of case and control groups was carried out. Information was collected of patients with CMA IgE+ from our department during the years 1990-2013. Patients of the same age and sex were recruited for the control group. Information on the following variables was collected: sex, age, pregnancy tolerance, duration of pregnancy, type of delivery, isolated doses of formula feeding in hospital (FFH), duration of breastfeeding, and family history of allergy (defined as ≥1 first-degree family member with allergic disease). Statistical analysis was performed using multivariate logistic regression techniques. A total of 211 cases were included in this study. Multivariate analysis showed an influence of duration of breastfeeding, FFH to be a risk factor (OR 4.94; 95% CI 2.68-9.08), especially in caesarean delivery (OR 11.82; 95% CI 2.64-47.50), and prematurity (OR 0.29; 95% CI 0.09-0.92) to be a protective factor. Perinatal factors play a key role in the development of CMA IgE+, with an influence of breastfeeding duration, FFH and caesarean delivery as risk factors and prematurity as a protective factor. While family history had no important role, environmental factors were more decisive. © 2017 S. Karger AG, Basel.
Factor analysis and multiple regression between topography and precipitation on Jeju Island, Korea
NASA Astrophysics Data System (ADS)
Um, Myoung-Jin; Yun, Hyeseon; Jeong, Chang-Sam; Heo, Jun-Haeng
2011-11-01
SummaryIn this study, new factors that influence precipitation were extracted from geographic variables using factor analysis, which allow for an accurate estimation of orographic precipitation. Correlation analysis was also used to examine the relationship between nine topographic variables from digital elevation models (DEMs) and the precipitation in Jeju Island. In addition, a spatial analysis was performed in order to verify the validity of the regression model. From the results of the correlation analysis, it was found that all of the topographic variables had a positive correlation with the precipitation. The relations between the variables also changed in accordance with a change in the precipitation duration. However, upon examining the correlation matrix, no significant relationship between the latitude and the aspect was found. According to the factor analysis, eight topographic variables (latitude being the exception) were found to have a direct influence on the precipitation. Three factors were then extracted from the eight topographic variables. By directly comparing the multiple regression model with the factors (model 1) to the multiple regression model with the topographic variables (model 3), it was found that model 1 did not violate the limits of statistical significance and multicollinearity. As such, model 1 was considered to be appropriate for estimating the precipitation when taking into account the topography. In the study of model 1, the multiple regression model using factor analysis was found to be the best method for estimating the orographic precipitation on Jeju Island.
Kang, Jina; Park, Kyoung-Ok
2017-01-01
The importance of training for Hospice and Palliative Care (HPC) professionals has been increasing with the systemization of HPC in Korea. Hence, the need and importance of training quality for HPC professionals are growing. This study evaluated the construct validity and reliability of the Evaluation Indicators for standard Hospice and Palliative Care Training (EIHPCT) program. As a framework to develop evaluation indicators, an invented theoretical model combining Stufflebeam's CIPP (Context-Input-Process-Product) evaluation model with PRECEDE-PROCEED model was used. To verify the construct validity of the EIHPCT program, a structured survey was performed with 169 professionals who were the HPC training program administrators, trainers, and trainees. To examine the validity of the areas of the EIHPCT program, exploratory factor analysis and confirmatory factor analysis were conducted. First, in the exploratory factor analysis, the indicators with factor loadings above 0.4 were chosen as desirable items, and some cross-loaded items that loaded at 0.4 or higher on two or more factors were adjusted as the higher factor. Second, the model fit of the modified EIHPCT program was quite good in the confirmatory factor analysis (Goodness-of-Fit Index > 0.70, Comparative Fit Index > 0.80, Normed Fit Index > 0.80, Root Mean square of Residuals < 0.05). The modified model of the EIHPCT comprised 4 areas, 13 subdomains, and 61 indicators. The evaluation indicators of the modified model will be valuable references for improving the HPC professional training program.
Tank bromeliad water: Similar or distinct environments for research of bacterial bioactives?
Carmo, F.L.; Santos, H.F.; Peixoto, R.S.; Rosado, A.S.; Araujo, F.V.
2014-01-01
The Atlantic Rainforest does not have a uniform physiognomy, its relief determines different environmental conditions that define the composition of its flora and fauna. Within this ecosystem, bromeliads that form tanks with their leaves hold water reservoirs throughout the year, maintaining complex food chains, based mainly on autotrophic and heterotrophic bacteria. Some works concluded that the water held by tank bromeliads concentrate the microbial diversity of their ecosystem. To investigate the bacterial diversity and the potential biotechnology of these ecosystems, tank bromeliads of the Neoregelia cruenta species from the Atlantic Rainforest in Brazil were used as models for this research. Bacteria isolated from these models were tested for production of bioactive compounds. DGGE of the water held by tank bromeliads was performed in different seasons, locations and sun exposure to verify whether these environmental factors affect bacterial communities. The DGGE bands profile showed no grouping of bacterial community by the environmental factors tested. Most of the isolates demonstrated promising activities in the tests performed. Collectively, these results suggest that tank bromeliads of the N. cruenta species provide important habitats for a diverse microbial community, suggesting that each tank forms a distinct micro-habitat. These tanks can be considered excellent sources for the search for new enzymes and/or new bioactive composites of microbial origin. PMID:24948929
Tank bromeliad water: similar or distinct environments for research of bacterial bioactives?
Carmo, F L; Santos, H F; Peixoto, R S; Rosado, A S; Araujo, F V
2014-01-01
The Atlantic Rainforest does not have a uniform physiognomy, its relief determines different environmental conditions that define the composition of its flora and fauna. Within this ecosystem, bromeliads that form tanks with their leaves hold water reservoirs throughout the year, maintaining complex food chains, based mainly on autotrophic and heterotrophic bacteria. Some works concluded that the water held by tank bromeliads concentrate the microbial diversity of their ecosystem. To investigate the bacterial diversity and the potential biotechnology of these ecosystems, tank bromeliads of the Neoregelia cruenta species from the Atlantic Rainforest in Brazil were used as models for this research. Bacteria isolated from these models were tested for production of bioactive compounds. DGGE of the water held by tank bromeliads was performed in different seasons, locations and sun exposure to verify whether these environmental factors affect bacterial communities. The DGGE bands profile showed no grouping of bacterial community by the environmental factors tested. Most of the isolates demonstrated promising activities in the tests performed. Collectively, these results suggest that tank bromeliads of the N. cruenta species provide important habitats for a diverse microbial community, suggesting that each tank forms a distinct micro-habitat. These tanks can be considered excellent sources for the search for new enzymes and/or new bioactive composites of microbial origin.
Visually Coupled Systems (VCS): The Virtual Panoramic Display (VPD) System
NASA Technical Reports Server (NTRS)
Kocian, Dean F.
1992-01-01
The development and impact is described of new visually coupled system (VCS) equipment designed to support engineering and human factors research in the military aircraft cockpit environment. VCS represents an advanced man-machine interface (MMI). Its potential to improve aircrew situational awareness seems enormous, but its superiority over the conventional cockpit MMI has not been established in a conclusive and rigorous fashion. What has been missing is a 'systems' approach to technology advancement that is comprehensive enough to produce conclusive results concerning the operational viability of the VCS concept and verify any risk factors that might be involved with its general use in the cockpit. The advanced VCS configuration described here, was ruggedized for use in military aircraft environments and was dubbed the Virtual Panoramic Display (VPD). It was designed to answer the VCS portion of the systems problem, and is implemented as a modular system whose performance can be tailored to specific application requirements. The overall system concept and the design of the two most important electronic subsystems that support the helmet mounted parts, a new militarized version of the magnetic helmet mounted sight and correspondingly similar helmet display electronics, are discussed in detail. Significant emphasis is given to illustrating how particular design features in the hardware improve overall system performance and support research activities.
Assessment of the performance of rigid pavement back-calculation through finite element modeling
NASA Astrophysics Data System (ADS)
Shoukry, Samir N.; William, Gergis W.; Martinelli, David R.
1999-02-01
This study focuses on examining the behavior of rigid pavement layers during the Falling Weight Deflectometer (FWD) test. Factors affecting the design of a concrete slab, such as whether the joints are doweled or undoweled and the spacing between the transverse joints, were considered in this study. Explicit finite element analysis was employed to investigate pavement layers' responses to the action of the impulse of the FWD test. Models of various dimensions were developed to satisfy the factors under consideration. The accuracy of the finite element models developed in this investigation was verified by comparing the finite element- generated deflection basin with that experimentally measured during an actual test. The results showed that the measured deflection basin can be reproduced through finite element modeling of the pavement structure. The resulting deflection basins from the use FE modeling was processed in order to backcalculate pavement layer moduli. This approach provides a method for the evaluation of the performance of existing backcalculation programs which are based on static elastic layer analysis. Based upon the previous studies conducted for the selection of software, three different backcalculation programs were chosen for the evaluation: MODULUS5.0, EVERCALC4.0, and MODCOMP3. The results indicate that ignoring the dynamic nature of the load may lead to crude results, especially during backcalculation procedures.
Development of 1D Liner Compression Code for IDL
NASA Astrophysics Data System (ADS)
Shimazu, Akihisa; Slough, John; Pancotti, Anthony
2015-11-01
A 1D liner compression code is developed to model liner implosion dynamics in the Inductively Driven Liner Experiment (IDL) where FRC plasmoid is compressed via inductively-driven metal liners. The driver circuit, magnetic field, joule heating, and liner dynamics calculations are performed at each time step in sequence to couple these effects in the code. To obtain more realistic magnetic field results for a given drive coil geometry, 2D and 3D effects are incorporated into the 1D field calculation through use of correction factor table lookup approach. Commercial low-frequency electromagnetic fields solver, ANSYS Maxwell 3D, is used to solve the magnetic field profile for static liner condition at various liner radius in order to derive correction factors for the 1D field calculation in the code. The liner dynamics results from the code is verified to be in good agreement with the results from commercial explicit dynamics solver, ANSYS Explicit Dynamics, and previous liner experiment. The developed code is used to optimize the capacitor bank and driver coil design for better energy transfer and coupling. FRC gain calculations are also performed using the liner compression data from the code for the conceptual design of the reactor sized system for fusion energy gains.
Verification of Decision-Analytic Models for Health Economic Evaluations: An Overview.
Dasbach, Erik J; Elbasha, Elamin H
2017-07-01
Decision-analytic models for cost-effectiveness analysis are developed in a variety of software packages where the accuracy of the computer code is seldom verified. Although modeling guidelines recommend using state-of-the-art quality assurance and control methods for software engineering to verify models, the fields of pharmacoeconomics and health technology assessment (HTA) have yet to establish and adopt guidance on how to verify health and economic models. The objective of this paper is to introduce to our field the variety of methods the software engineering field uses to verify that software performs as expected. We identify how many of these methods can be incorporated in the development process of decision-analytic models in order to reduce errors and increase transparency. Given the breadth of methods used in software engineering, we recommend a more in-depth initiative to be undertaken (e.g., by an ISPOR-SMDM Task Force) to define the best practices for model verification in our field and to accelerate adoption. Establishing a general guidance for verifying models will benefit the pharmacoeconomics and HTA communities by increasing accuracy of computer programming, transparency, accessibility, sharing, understandability, and trust of models.
What's Happening on the School Bus Performance Front?
ERIC Educational Resources Information Center
Combs, Hanford L.
The most urgent order of business in the national scene is to complete the development of a series of new performance tests for school bus bodies and chassis to establish a benchmark for safe construction that can be verified by independent testing agencies. Such performance tests should incorporate the new Federal Joint Strength Efficiency…
Wei, T-T; Wang, L-L; Yin, J-R; Liu, Y-T; Qin, B-D; Li, J-Y; Yin, X; Zhou, L; Zhong, R-Q
2017-10-01
Red blood cell distribution width (RDW) and bilirubin have been proved to be prognostic factors for various types of cancer. However, their prognostic value in patients with gastric cancer (GC) remains largely unknown. To verify whether RDW and bilirubin are prognostic factors for patients with GC, we performed a cross-sectional study to analyze the relationship between RDW, bilirubin, and the clinical characteristics of patients with GC. Medical records of all newly diagnosed and pathologically proved patients with GC admitted to Changzheng Hospital between January 2016 and July 2016 were retrospectively reviewed. The relationship between RDW, bilirubin, and the clinical characteristics of patients with GC was analyzed. A total of 144 patients with GC were enrolled. Patients with GC had significantly higher RDW than healthy controls, even after adjusting for hemoglobin, while total bilirubin (TBIL), direct bilirubin (DBIL) and indirect bilirubin (IBIL) were significantly decreased. Furthermore, RDW and bilirubin were significantly correlated with tumor stage, as well as carcinoembryonic antigen (CEA) and carbohydrate antigen 19-9 (CA19-9). Our study indicated that RDW and bilirubin could be potential prognostic factors for patients of GC. © 2017 John Wiley & Sons Ltd.
AE characteristic for monitoring of fatigue crack in steel bridge members
NASA Astrophysics Data System (ADS)
Yoon, Dong-Jin; Jung, Juong-Chae; Park, Philip; Lee, Seung-Seok
2000-06-01
Acoustic emission technique was employed for the monitoring of crack activity in both steel bridge members and laboratory specimen. Laboratory experiment was carried out to identify AE characteristics of fatigue cracks for compact tension specimen. The relationship between a stress intensity factor and AE signals activity as well as conventional AE parameter analysis was discussed. A field test was also conducted on a railway bridge, which contain several fatigue cracks. Crack activities were investigated while in service with strain measurement. From the results, in the laboratory tests, the features of three parameters such as the length of crack growth, the AE energy, and the cumulative AE events, showed the almost same trend in their increase as the number of fatigue cycle increased. From the comparisons of peak amplitude and AE energy with stress intensity factor, it was verified that the higher stress intensity factors generated AE signals with higher peak amplitude and a large number of AE counts. In the field test, real crack propagation signals were captured and the crack activity was verified in two cases.
Conservation of hot regions in protein-protein interaction in evolution.
Hu, Jing; Li, Jiarui; Chen, Nansheng; Zhang, Xiaolong
2016-11-01
The hot regions of protein-protein interactions refer to the active area which formed by those most important residues to protein combination process. With the research development on protein interactions, lots of predicted hot regions can be discovered efficiently by intelligent computing methods, while performing biology experiments to verify each every prediction is hardly to be done due to the time-cost and the complexity of the experiment. This study based on the research of hot spot residue conservations, the proposed method is used to verify authenticity of predicted hot regions that using machine learning algorithm combined with protein's biological features and sequence conservation, though multiple sequence alignment, module substitute matrix and sequence similarity to create conservation scoring algorithm, and then using threshold module to verify the conservation tendency of hot regions in evolution. This research work gives an effective method to verify predicted hot regions in protein-protein interactions, which also provides a useful way to deeply investigate the functional activities of protein hot regions. Copyright © 2016. Published by Elsevier Inc.
Formal Validation of Fault Management Design Solutions
NASA Technical Reports Server (NTRS)
Gibson, Corrina; Karban, Robert; Andolfato, Luigi; Day, John
2013-01-01
The work presented in this paper describes an approach used to develop SysML modeling patterns to express the behavior of fault protection, test the model's logic by performing fault injection simulations, and verify the fault protection system's logical design via model checking. A representative example, using a subset of the fault protection design for the Soil Moisture Active-Passive (SMAP) system, was modeled with SysML State Machines and JavaScript as Action Language. The SysML model captures interactions between relevant system components and system behavior abstractions (mode managers, error monitors, fault protection engine, and devices/switches). Development of a method to implement verifiable and lightweight executable fault protection models enables future missions to have access to larger fault test domains and verifiable design patterns. A tool-chain to transform the SysML model to jpf-Statechart compliant Java code and then verify the generated code via model checking was established. Conclusions and lessons learned from this work are also described, as well as potential avenues for further research and development.
Checkout and Standard Use Procedures for the Mark III Space Suit Assembly
NASA Technical Reports Server (NTRS)
Valish, Dana J.
2012-01-01
The operational pressure range is the range to which the suit can be nominally operated for manned testing. The top end of the nominal operational pressure range is equivalent to 1/2 the proof pressure. Structural pressure is 1.5 times the specified test pressure for any given test. Proof pressure is the maximum unmanned pressure to which the suit was tested by the vendor prior to delivery. The maximum allowable working pressure (MAWP) is 90% of the proof pressure. The pressure systems RVs are set to keep components below their MAWPs. If the suit is pressurized over its MAWP, the suit will be taken out of service and an in-depth inspection/review of the suit will be performed before the suit is put back in service. The procedures outlined in this document should be followed as written. However, the suit test engineer (STE) may make redline changes real-time, provided those changes are recorded in the anomaly section of the test data sheet. If technicians supporting suit build-up, check-out, and/or test execution believe that a procedure can be improved, they should notify their lead. If procedures are incorrect to the point of potentially causing hardware damage or affecting safety, bring the problem to the technician lead and/or STE s attention and stop work until a solution (temporary or permanent) is authorized. Certain steps in the procedure are marked with a DV , for Designated Verifier. The Designated Verifier for this procedure is an Advanced Space Suit Technology Development Laboratory technician, not directly involved in performing the procedural steps, who will verify that the step was performed as stated. The steps to be verified by the DV were selected based on one or more of the following criteria: the step was deemed significant in ensuring the safe performance of the test, the data recorded in the step is of specific interest in monitoring the suit system operation, or the step has a strong influence on the successful completion of test objectives. Prior to all manned test activities, Advanced Suit Test Data Sheet (TDS) Parts A-E shall be completed to verify system and team are ready for test. Advanced Suit TDS Parts F-G shall be completed at the end of the suited activity. Appendix B identifies tha appropriate Mark III suit emergency event procedures.
AN ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) PERFORMANCE TESTING OF FOUR IMMUNOASSAY TEST KITS
The Environmental Technology Verification (ETV) Program, beginning as an initiative of the U.S. Environmental Protection Agency (EPA) in 1995, verifies the performance of commercially available, innovative technologies that can be used to measure environmental quality. The ETV p...
PERFORMANCE VERIFICATION OF ADVANCED MONITORING SYSTEMS FOR AIR, WATER, AND SOIL
The Environmental Technology Verification (ETV) Program, beginning as an initiative of the U.S. Environmental Protection Agency (EPA) in 1995, verifies the performance of commercially available, innovative technologies that can be used to assess environmental quality. The ETV p...
Association between cotinine-verified smoking status and hypertension in 167,868 Korean adults.
Kim, Byung Jin; Han, Ji Min; Kang, Jung Gyu; Kim, Bum Soo; Kang, Jin Ho
2017-10-01
Previous studies showed inconsistent results concerning the relationship between chronic smoking and blood pressure. Most of the studies involved self-reported smoking status. This study was performed to evaluate the association of urinary cotinine or self-reported smoking status with hypertension and blood pressure in Korean adults. Among individuals enrolled in the Kangbuk Samsung Health Study and Kangbuk Samsung Cohort Study, 167,868 participants (men, 55.7%; age, 37.5 ± 6.9 years) between 2011 and 2013 who had urinary cotinine measurements were included. Individuals with urinary cotinine levels ≥50 ng/mL were defined as cotinine-verified current smokers. The prevalence of hypertension and cotinine-verified current smokers in the overall population was 6.8% and 22.7%, respectively (10.0% in men and 2.8% in women for hypertension: 37.7% in men and 3.9% in women for cotinine-verified current smokers). In a multivariate regression analysis adjusted for age, sex, body mass index, waist circumference, alcohol drinking, vigorous exercise, and diabetes, cotinine-verified current smoking was associated with lower prevalence of hypertension compared with cotinine-verified never smoking (OR[95% CI], 0.79 [0.75, 0.84]). Log-transformed cotinine levels and unobserved smoking were negatively associated with hypertension, respectively (0.96 [0.96, 0.97] and 0.55 [0.39, 0.79]). In a multivariate linear regression analysis, the cotinine-verified current smoking was inversely associated with systolic and diastolic blood pressure (BP) (regression coefficient[95% CI], -1.23[-1.39, -1.07] for systolic BP and -0.71 [-0.84, -0.58] for diastolic BP). In subgroup analyses according to sex, the inverse associations between cotinine-verified current smoking and hypertension were observed only in men. This large observational study showed that cotinine-verified current smoking and unobserved smoking were inversely associated with hypertension in Korean adults, especially only in men.
The phase slip factor of the electrostatic cryogenic storage ring CSR
NASA Astrophysics Data System (ADS)
Grieser, Manfred; von Hahn, Robert; Vogel, Stephen; Wolf, Andreas
2017-07-01
To determine the momentum spread of an ion beam from the measured revolution frequency distribution, the knowledge of the phase slip factor of the storage ring is necessary. The slip factor was measured for various working points of the cryogenic storage ring CSR at MPI for Nuclear Physics, Heidelberg and was compared with simulations. The predicted functional relationship of the slip factor and the horizontal tune depends on the different islands of stability, which has been experimentally verified. This behavior of the slip factor is in clear contrast to that of magnetic storage rings.
Characterization of an improved 1-3 piezoelectric composite by simulation and experiment.
Zhong, Chao; Wang, Likun; Qin, Lei; Zhang, Yanjun
2017-06-16
To increase electromechanical coupling factor of 1-3 piezoelectric composite and reduce its bending deformation under external stress, an improved 1-3 piezoelectric composite is developed. In the improved structure, both epoxy resin and silicone rubber are used as polymer material. The simulation model of the improved 1-3 piezoelectric composite was established using the finite element software ANSYS. The relationship of the performance of the improved composite to the volume percentage of silicone rubber was determined by harmonic response analysis and the bending deformation under external stress was simulated by static analysis. The improved composite samples were prepared by cutting and filling methods, and the performance was tested. The feasibility of the improved structure was verified by finite element simulation and experiment. The electromechanical coupling factor of the improved composite can reach 0.67 and meanwhile the characteristic impedance can decline to 13 MRayl. The electromechanical coupling factor of the improved composite is higher than that of the composite with only epoxy resin as the polymer and the improved composite can reduce bending deformation. Comparison of simulation and experiment, the results of the experiment are in general agreement with those from the simulation. However, most experimental values were higher than the simulation results, and the abnormality of the test results was also more obvious than that of the simulation. These findings may be attributed to slight difference in the material parameters of simulation and experiment.
Overheating Anomalies during Flight Test Due to the Base Bleeding
NASA Technical Reports Server (NTRS)
Luchinsky, Dmitry; Hafiychuck, Halyna; Osipov, Slava; Ponizhovskaya, Ekaterina; Smelyanskiy, Vadim; Dagostino, Mark; Canabal, Francisco; Mobley, Brandon L.
2012-01-01
In this paper we present the results of the analytical and numerical studies of the plume interaction with the base flow in the presence of base out-gassing. The physics-based analysis and CFD modeling of the base heating for single solid rocket motor performed in this research addressed the following questions: what are the key factors making base flow so different from that in the Shuttle [1]; why CFD analysis of this problem reveals small plume recirculation; what major factors influence base temperature; and why overheating was initiated at a given time in the flight. To answer these questions topological analysis of the base flow was performed and Korst theory was used to estimate relative contributions of radiation, plume recirculation, and chemically reactive out-gassing to the base heating. It was shown that base bleeding and small base volume are the key factors contributing to the overheating, while plume recirculation is effectively suppressed by asymmetric configuration of the flow formed earlier in the flight. These findings are further verified using CFD simulations that include multi-species gas environment both in the plume and in the base. Solid particles in the exhaust plume (Al2O3) and char particles in the base bleeding were also included into the simulations and their relative contributions into the base temperature rise were estimated. The results of simulations are in good agreement with the temperature and pressure in the base measured during the test.
NASA Astrophysics Data System (ADS)
Bashiri, Mahdi; Farshbaf-Geranmayeh, Amir; Mogouie, Hamed
2013-11-01
In this paper, a new method is proposed to optimize a multi-response optimization problem based on the Taguchi method for the processes where controllable factors are the smaller-the-better (STB)-type variables and the analyzer desires to find an optimal solution with smaller amount of controllable factors. In such processes, the overall output quality of the product should be maximized while the usage of the process inputs, the controllable factors, should be minimized. Since all possible combinations of factors' levels, are not considered in the Taguchi method, the response values of the possible unpracticed treatments are estimated using the artificial neural network (ANN). The neural network is tuned by the central composite design (CCD) and the genetic algorithm (GA). Then data envelopment analysis (DEA) is applied for determining the efficiency of each treatment. Although the important issue for implementation of DEA is its philosophy, which is maximization of outputs versus minimization of inputs, this important issue has been neglected in previous similar studies in multi-response problems. Finally, the most efficient treatment is determined using the maximin weight model approach. The performance of the proposed method is verified in a plastic molding process. Moreover a sensitivity analysis has been done by an efficiency estimator neural network. The results show efficiency of the proposed approach.
Golino, Hudson F.; Epskamp, Sacha
2017-01-01
The estimation of the correct number of dimensions is a long-standing problem in psychometrics. Several methods have been proposed, such as parallel analysis (PA), Kaiser-Guttman’s eigenvalue-greater-than-one rule, multiple average partial procedure (MAP), the maximum-likelihood approaches that use fit indexes as BIC and EBIC and the less used and studied approach called very simple structure (VSS). In the present paper a new approach to estimate the number of dimensions will be introduced and compared via simulation to the traditional techniques pointed above. The approach proposed in the current paper is called exploratory graph analysis (EGA), since it is based on the graphical lasso with the regularization parameter specified using EBIC. The number of dimensions is verified using the walktrap, a random walk algorithm used to identify communities in networks. In total, 32,000 data sets were simulated to fit known factor structures, with the data sets varying across different criteria: number of factors (2 and 4), number of items (5 and 10), sample size (100, 500, 1000 and 5000) and correlation between factors (orthogonal, .20, .50 and .70), resulting in 64 different conditions. For each condition, 500 data sets were simulated using lavaan. The result shows that the EGA performs comparable to parallel analysis, EBIC, eBIC and to Kaiser-Guttman rule in a number of situations, especially when the number of factors was two. However, EGA was the only technique able to correctly estimate the number of dimensions in the four-factor structure when the correlation between factors were .7, showing an accuracy of 100% for a sample size of 5,000 observations. Finally, the EGA was used to estimate the number of factors in a real dataset, in order to compare its performance with the other six techniques tested in the simulation study. PMID:28594839
Zanin, Francisca Helena Calheiros; da Silva, Camilo Adalton Mariano; Bonomo, Élido; Teixeira, Romero Alves; Pereira, Cíntia Aparecida de Jesus; dos Santos, Karina Benatti; Fausto, Maria Arlene; Negrão-Correa, Deborah Aparecida; Lamounier, Joel Alves; Carneiro, Mariângela
2015-01-01
Iron deficiency anemia is one of the most common nutritional disorders worldwide. The aim was to identify the prevalence and incidence of anemia in children and to identify predictors of this condition, including intestinal parasites, social, nutritional and environmental factors, and comorbidities. A population-based cohort study was conducted in a sample of 414 children aged 6–71 months living in Novo Cruzeiro in the Minas Gerais State. Data were collected in 2008 and 2009 by interview and included socio-economic and demographic information about the children and their families. Blood samples were collected for testing of hemoglobin, ferritin and C-reactive protein. Anthropometric measurements and parasitological analyses of fecal samples were performed. To identify risk factors associated with anemia multivariate analyses were performed using the generalized estimating equations (GEE). In 2008 and 2009, respectively, the prevalence rates of anemia were 35.9% (95%CI 31.2–40.8) and 9.8% (95%CI 7.2–12.9), the prevalence rates of iron deficiency were 18.4% (95%CI 14.7–22.6) and 21.8% (95%CI 17.8–26.2), and the incidence rates of anemia and iron deficiency were 3.2% and 21.8%. The following risk factors associated with anemia were: iron deficiency (OR = 3.2; 95%CI 2.0-.5.3), parasitic infections (OR = 1.9; 95%CI 1.2–2.8), being of risk of or being a low length/height-for-age (OR = 2.1; 95%CI 1.4–3.2), and lower retinol intake (OR = 1.7; 95%CI 1.1–2.7), adjusted over time. Nutritional factors, parasitic infections and chronic malnutrition were identified as risk factors for anemia. These factors can be verified in a chronic process and have been classically described as risk factors for these conditions. PMID:26445270
Zanin, Francisca Helena Calheiros; da Silva, Camilo Adalton Mariano; Bonomo, Élido; Teixeira, Romero Alves; Pereira, Cíntia Aparecida de Jesus; dos Santos, Karina Benatti; Fausto, Maria Arlene; Negrão-Correa, Deborah Aparecida; Lamounier, Joel Alves; Carneiro, Mariângela
2015-01-01
Iron deficiency anemia is one of the most common nutritional disorders worldwide. The aim was to identify the prevalence and incidence of anemia in children and to identify predictors of this condition, including intestinal parasites, social, nutritional and environmental factors, and comorbidities. A population-based cohort study was conducted in a sample of 414 children aged 6-71 months living in Novo Cruzeiro in the Minas Gerais State. Data were collected in 2008 and 2009 by interview and included socio-economic and demographic information about the children and their families. Blood samples were collected for testing of hemoglobin, ferritin and C-reactive protein. Anthropometric measurements and parasitological analyses of fecal samples were performed. To identify risk factors associated with anemia multivariate analyses were performed using the generalized estimating equations (GEE). In 2008 and 2009, respectively, the prevalence rates of anemia were 35.9% (95%CI 31.2-40.8) and 9.8% (95%CI 7.2-12.9), the prevalence rates of iron deficiency were 18.4% (95%CI 14.7-22.6) and 21.8% (95%CI 17.8-26.2), and the incidence rates of anemia and iron deficiency were 3.2% and 21.8%. The following risk factors associated with anemia were: iron deficiency (OR = 3.2; 95%CI 2.0-.5.3), parasitic infections (OR = 1.9; 95%CI 1.2-2.8), being of risk of or being a low length/height-for-age (OR = 2.1; 95%CI 1.4-3.2), and lower retinol intake (OR = 1.7; 95%CI 1.1-2.7), adjusted over time. Nutritional factors, parasitic infections and chronic malnutrition were identified as risk factors for anemia. These factors can be verified in a chronic process and have been classically described as risk factors for these conditions.
Golino, Hudson F; Epskamp, Sacha
2017-01-01
The estimation of the correct number of dimensions is a long-standing problem in psychometrics. Several methods have been proposed, such as parallel analysis (PA), Kaiser-Guttman's eigenvalue-greater-than-one rule, multiple average partial procedure (MAP), the maximum-likelihood approaches that use fit indexes as BIC and EBIC and the less used and studied approach called very simple structure (VSS). In the present paper a new approach to estimate the number of dimensions will be introduced and compared via simulation to the traditional techniques pointed above. The approach proposed in the current paper is called exploratory graph analysis (EGA), since it is based on the graphical lasso with the regularization parameter specified using EBIC. The number of dimensions is verified using the walktrap, a random walk algorithm used to identify communities in networks. In total, 32,000 data sets were simulated to fit known factor structures, with the data sets varying across different criteria: number of factors (2 and 4), number of items (5 and 10), sample size (100, 500, 1000 and 5000) and correlation between factors (orthogonal, .20, .50 and .70), resulting in 64 different conditions. For each condition, 500 data sets were simulated using lavaan. The result shows that the EGA performs comparable to parallel analysis, EBIC, eBIC and to Kaiser-Guttman rule in a number of situations, especially when the number of factors was two. However, EGA was the only technique able to correctly estimate the number of dimensions in the four-factor structure when the correlation between factors were .7, showing an accuracy of 100% for a sample size of 5,000 observations. Finally, the EGA was used to estimate the number of factors in a real dataset, in order to compare its performance with the other six techniques tested in the simulation study.
Chelton, C F; Zakraysek, N; Lautner, G M; Confer, R G
1983-10-01
Two direct reading instruments, the H-Nu PI 101 photoionization analyzer and the J.W. Bacharach TLV Sniffer, were evaluated under laboratory conditions to determine their performance characteristics when challenged by vapors of common hydrocarbon solvent mixtures. Each instrument was evaluated against the manufacturer's recommended test solvent for rise time, fall time, noise, span drift, zero drift, position sensitivity, battery life, and recharge time. The precision, accuracy, and operating linear range were also determined for the test solvents and some petroleum solvent mixtures which are common refinery products. For these latter mixtures, correction factors are presented which allow for an improved estimate of ambient concentrations when monitoring with each of these instruments. All tests except operating humidity range were performed by challenging each instrument with a known concentration of hydrocarbon generated by evaporating calculated liquid volumes into a static chamber. Humidity tests were performed using a dynamic dilution apparatus generating a fixed concentration of hydrocarbon while relative humidity was varied. Concentrations in both systems were verified by gas injection into gas chromatograph. Each instrument performed well when challenged by manufacturers' recommended test solvents. Humidity was shown to influence each instrument's readings. Also, the instruments were shown to have application as monitors of airborne concentrations of common hydrocarbon solvent mixtures.
E-Learning and the University of Huelva: A Study of WebCT and the Technological Acceptance Model
ERIC Educational Resources Information Center
Sanchez, R. Arteaga; Hueros, A. Duarte; Ordaz, M. Garcia
2013-01-01
Purpose: The purpose of this paper is to investigate the factors that determine the acceptance of the WebCT learning system among students of the faculties of Business and Education Sciences at the University of Huelva, and to verify the direct and indirect effects of these factors. Design/methodology/approach: A total of 226 students at the…
De Vries, Rowen J; Marsh, Steven
2015-11-08
Internal lead shielding is utilized during superficial electron beam treatments of the head and neck, such as lip carcinoma. Methods for predicting backscattered dose include the use of empirical equations or performing physical measurements. The accuracy of these empirical equations required verification for the local electron beams. In this study, a Monte Carlo model of a Siemens Artiste linac was developed for 6, 9, 12, and 15 MeV electron beams using the EGSnrc MC package. The model was verified against physical measurements to an accuracy of better than 2% and 2mm. Multiple MC simulations of lead interfaces at different depths, corresponding to mean electron energies in the range of 0.2-14 MeV at the interfaces, were performed to calculate electron backscatter values. The simulated electron backscatter was compared with current empirical equations to ascertain their accuracy. The major finding was that the current set of backscatter equations does not accurately predict electron backscatter, particularly in the lower energies region. A new equation was derived which enables estimation of electron backscatter factor at any depth upstream from the interface for the local treatment machines. The derived equation agreed to within 1.5% of the MC simulated electron backscatter at the lead interface and upstream positions. Verification of the equation was performed by comparing to measurements of the electron backscatter factor using Gafchromic EBT2 film. These results show a mean value of 0.997 ± 0.022 to 1σ of the predicted values of electron backscatter. The new empirical equation presented can accurately estimate electron backscatter factor from lead shielding in the range of 0.2 to 14 MeV for the local linacs.
Marsh, Steven
2015-01-01
Internal lead shielding is utilized during superficial electron beam treatments of the head and neck, such as lip carcinoma. Methods for predicting backscattered dose include the use of empirical equations or performing physical measurements. The accuracy of these empirical equations required verification for the local electron beams. In this study, a Monte Carlo model of a Siemens Artiste linac was developed for 6, 9, 12, and 15 MeV electron beams using the EGSnrc MC package. The model was verified against physical measurements to an accuracy of better than 2% and 2 mm. Multiple MC simulations of lead interfaces at different depths, corresponding to mean electron energies in the range of 0.2–14 MeV at the interfaces, were performed to calculate electron backscatter values. The simulated electron backscatter was compared with current empirical equations to ascertain their accuracy. The major finding was that the current set of backscatter equations does not accurately predict electron backscatter, particularly in the lower energies region. A new equation was derived which enables estimation of electron backscatter factor at any depth upstream from the interface for the local treatment machines. The derived equation agreed to within 1.5% of the MC simulated electron backscatter at the lead interface and upstream positions. Verification of the equation was performed by comparing to measurements of the electron backscatter factor using Gafchromic EBT2 film. These results show a mean value of 0.997±0.022 to 1σ of the predicted values of electron backscatter. The new empirical equation presented can accurately estimate electron backscatter factor from lead shielding in the range of 0.2 to 14 MeV for the local linacs. PACS numbers: 87.53.Bn, 87.55.K‐, 87.56.bd PMID:26699566
Martoni, Riccardo Maria; Brombin, Chiara; Nonis, Alessandro; Salgari, Giulia Carlotta; Buongiorno, Angela; Cavallini, Maria Cristina; Galimberti, Elisa; Bellodi, Laura
2015-07-01
Despite having a univocal definition, obsessive-compulsive disorder (OCD) shows a remarkably phenotypic heterogeneity. The published reports show impaired decision-making in OCD patients, using tasks such as the Iowa Gambling Task (IGT). We wanted to verify the hypothesis of an IGT worse performance in a large sample of OCD patients and healthy control (HC) subjects and to examine the relation between neuropsychological performance in IGT and the OCD symptoms heterogeneity. Binary data from the Yale-Brown Obsessive Compulsive Scale collected on a large sample of OCD patients were analyzed using a multidimensional item response theory model to explore the underlying structure of data, thus revealing latent factors. Factor scores were categorized into quartiles. Then, for each factor, we identified patients respectively with the highest versus lowest score. We evaluated whether symptom dimensions affect the probability of a correct answer over time generalized, during IGT performance, fitting a generalized linear mixed model. We found a general deficit in ambiguous decision-making in OCD compared to HC. Moreover, our findings suggested that OCD symptoms heterogeneity affects decision-making learning abilities during IGT. In fact, while 'Symmetry' and 'Washing' patients showed a learning curve during the task, other subgroups did not. Our study confirmed previous findings suggesting that OCD is characterized by a deficit in decision-making under uncertainty. Moreover, our study gave evidence about biological specificity for each symptom dimension in OCD. Data were discussed in the context of the somatic marker hypothesis, which was hypothesized to be reduced in OCD patients. © 2014 The Authors. Psychiatry and Clinical Neurosciences © 2014 Japanese Society of Psychiatry and Neurology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Indelicato, I.; La Cognata, M.; Spitaleri, C.
Fluorine abundance determination is of great importance in stellar physics to understand s-elements production and mixing processes in asymptotic giant branch (AGB) stars. Up to now, theoretical models overproduce F abundances in AGB stars with respect to the observed values, thus calling for further investigation of the reactions involving fluorine. In particular, the {sup 19}F( p , α ){sup 16}O reaction is the main destruction channel of fluorine at the bottom of the convective envelope in AGB stars, an H-rich environment where it can experience temperatures high enough to determine its destruction, owing to additional mixing processes. In this papermore » the Trojan horse method (THM) was used to extract the {sup 19}F( p , α {sub 0}){sup 16}O S-factor in the energy range of astrophysical interest ( E {sub cm} ≈ 0–1 MeV). This is the most relevant channel at the low temperatures (few 10{sup 7} K) characterizing the bottom of the convective envelope, according to current knowledge. A previous indirect experiment using the THM has observed three resonances in the energy regions below E {sub cm} ≈ 450 keV. These energies correspond to typical AGB temperatures, thus implying a significant increase in the reaction rate. Statistics are scarce for performing an accurate separation between resonances, preventing one from drawing a quantitative conclusion about their total widths and spin parities. Before THM measurement, only extrapolations were available below about 500 keV, showing a non-resonant behavior that sharply contradicts the trend of the astrophysical factor at higher energies. A new experiment has been performed to verify the measured TH astrophysical factor and to perform more accurate spectroscopy of the involved resonances.« less
Teklu, Berhan M; Retta, Negussie; Van den Brink, Paul J
2016-08-01
The aims of the present study were to present a methodology for toxicity tests that can be used when analytical resources to verify the test concentrations are limited, and to evaluate whether the sensitivity of a limited number of Ethiopian species to pesticides differs from literature values for, mainly, temperate species. Acute toxicity tests were performed using three Ethiopian aquatic invertebrate species, one crustacean (Diaphanosoma brachyurum) and two insects (Anopheles pharoensis and Culex pipiens) and using the pesticides endosulfan and diazinon. All species-pesticide combinations were tested in duplicate to estimate the consistency, i.e. the intra-laboratory variation, in test results. Daphnia magna was tested as well to allow the test results to be compared directly with values from the literature. Results indicate that the differences between the EC50s obtained for D. magna in this study and those reported in the literature were less than a factor of 2. This indicates that the methodology used is able to provide credible toxicity values. The results of the duplicated tests showed intra-laboratory variation in EC50 values of up to a factor of 3, with one test showing a difference of a factor of 6 at 48 h. Comparison with available literature results for arthropod species using species sensitivity distributions indicated that the test results obtained in this study fit well in the log-normal distribution of the literature values. We conclude that the methodology of performing multiple tests to check for consistency of test results and performing tests with D. magna for comparison with literature values to check for accuracy is able to provide reliable effect threshold levels and that the tested Ethiopian species did not differ in sensitivity from the arthropod species reported on in the literature.
Ashengroph, Morahem; Ababaf, Sajad
2014-12-01
Microbial caffeine removal is a green solution for treatment of caffeinated products and agro-industrial effluents. We directed this investigation to optimizing a bio-decaffeination process with growing cultures of Pseudomonas pseudoalcaligenes through Taguchi methodology which is a structured statistical approach that can be lowered variations in a process through Design of Experiments (DOE). Five parameters, i.e. initial fructose, tryptone, Zn(+2) ion and caffeine concentrations and also incubation time selected and an L16 orthogonal array was applied to design experiments with four 4-level factors and one 3-level factor (4(4) × 1(3)). Data analysis was performed using the statistical analysis of variance (ANOVA) method. Furthermore, the optimal conditions were determined by combining the optimal levels of the significant factors and verified by a confirming experiment. Measurement of residual caffeine concentration in the reaction mixture was performed using high-performance liquid chromatography (HPLC). Use of Taguchi methodology for optimization of design parameters resulted in about 86.14% reduction of caffeine in 48 h incubation when 5g/l fructose, 3 mM Zn(+2) ion and 4.5 g/l of caffeine are present in the designed media. Under the optimized conditions, the yield of degradation of caffeine (4.5 g/l) by the native strain of Pseudomonas pseudoalcaligenes TPS8 has been increased from 15.8% to 86.14% which is 5.4 fold higher than the normal yield. According to the experimental results, Taguchi methodology provides a powerful methodology for identifying the favorable parameters on caffeine removal using strain TPS8 which suggests that the approach also has potential application with similar strains to improve the yield of caffeine removal from caffeine containing solutions.
Performance evaluation of an agent-based occupancy simulation model
Luo, Xuan; Lam, Khee Poh; Chen, Yixing; ...
2017-01-17
Occupancy is an important factor driving building performance. Static and homogeneous occupant schedules, commonly used in building performance simulation, contribute to issues such as performance gaps between simulated and measured energy use in buildings. Stochastic occupancy models have been recently developed and applied to better represent spatial and temporal diversity of occupants in buildings. However, there is very limited evaluation of the usability and accuracy of these models. This study used measured occupancy data from a real office building to evaluate the performance of an agent-based occupancy simulation model: the Occupancy Simulator. The occupancy patterns of various occupant types weremore » first derived from the measured occupant schedule data using statistical analysis. Then the performance of the simulation model was evaluated and verified based on (1) whether the distribution of observed occupancy behavior patterns follows the theoretical ones included in the Occupancy Simulator, and (2) whether the simulator can reproduce a variety of occupancy patterns accurately. Results demonstrated the feasibility of applying the Occupancy Simulator to simulate a range of occupancy presence and movement behaviors for regular types of occupants in office buildings, and to generate stochastic occupant schedules at the room and individual occupant levels for building performance simulation. For future work, model validation is recommended, which includes collecting and using detailed interval occupancy data of all spaces in an office building to validate the simulated occupant schedules from the Occupancy Simulator.« less
Performance evaluation of an agent-based occupancy simulation model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luo, Xuan; Lam, Khee Poh; Chen, Yixing
Occupancy is an important factor driving building performance. Static and homogeneous occupant schedules, commonly used in building performance simulation, contribute to issues such as performance gaps between simulated and measured energy use in buildings. Stochastic occupancy models have been recently developed and applied to better represent spatial and temporal diversity of occupants in buildings. However, there is very limited evaluation of the usability and accuracy of these models. This study used measured occupancy data from a real office building to evaluate the performance of an agent-based occupancy simulation model: the Occupancy Simulator. The occupancy patterns of various occupant types weremore » first derived from the measured occupant schedule data using statistical analysis. Then the performance of the simulation model was evaluated and verified based on (1) whether the distribution of observed occupancy behavior patterns follows the theoretical ones included in the Occupancy Simulator, and (2) whether the simulator can reproduce a variety of occupancy patterns accurately. Results demonstrated the feasibility of applying the Occupancy Simulator to simulate a range of occupancy presence and movement behaviors for regular types of occupants in office buildings, and to generate stochastic occupant schedules at the room and individual occupant levels for building performance simulation. For future work, model validation is recommended, which includes collecting and using detailed interval occupancy data of all spaces in an office building to validate the simulated occupant schedules from the Occupancy Simulator.« less
Research on Modelling of Aviation Piston Engine for the Hardware-in-the-loop Simulation
NASA Astrophysics Data System (ADS)
Yu, Bing; Shu, Wenjun; Bian, Wenchao
2016-11-01
In order to build the aero piston engine model which is real-time and accurate enough to operating conditions of the real engine for hardware in the loop simulation, the mean value model is studied. Firstly, the air-inlet model, the fuel model and the power-output model are established separately. Then, these sub models are combined and verified in MATLAB/SIMULINK. The results show that the model could reflect the steady-state and dynamic performance of aero engine, the errors between the simulation results and the bench test data are within the acceptable range. The model could be applied to verify the logic performance and control strategy of controller in the hardware-in-the-loop (HIL) simulation.
Simulation of periodically focused, adiabatic thermal beams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, C.; Akylas, T. R.; Barton, T. J.
2012-12-21
Self-consistent particle-in-cell simulations are performed to verify earlier theoretical predictions of adiabatic thermal beams in a periodic solenoidal magnetic focusing field [K.R. Samokhvalova, J. Zhou and C. Chen, Phys. Plasma 14, 103102 (2007); J. Zhou, K.R. Samokhvalova and C. Chen, Phys. Plasma 15, 023102 (2008)]. In particular, results are obtained for adiabatic thermal beams that do not rotate in the Larmor frame. For such beams, the theoretical predictions of the rms beam envelope, the conservations of the rms thermal emittances, the adiabatic equation of state, and the Debye length are verified in the simulations. Furthermore, the adiabatic thermal beam ismore » found be stable in the parameter regime where the simulations are performed.« less
Code of Federal Regulations, 2011 CFR
2011-07-01
... engine and sampling systems. (7) Sample emissions throughout the duty cycle. (8) Record post-test data. (9) Perform post-test procedures to verify proper operation of certain equipment and analyzers. (10... PROCEDURES Performing an Emission Test Over Specified Duty Cycles § 1065.501 Overview. (a) Use the procedures...
Code of Federal Regulations, 2010 CFR
2010-07-01
... engine and sampling systems. (7) Sample emissions throughout the duty cycle. (8) Record post-test data. (9) Perform post-test procedures to verify proper operation of certain equipment and analyzers. (10... PROCEDURES Performing an Emission Test Over Specified Duty Cycles § 1065.501 Overview. (a) Use the procedures...
Code of Federal Regulations, 2014 CFR
2014-07-01
... engine and sampling systems. (7) Sample emissions throughout the duty cycle. (8) Record post-test data. (9) Perform post-test procedures to verify proper operation of certain equipment and analyzers. (10... PROCEDURES Performing an Emission Test Over Specified Duty Cycles § 1065.501 Overview. (a) Use the procedures...
Code of Federal Regulations, 2013 CFR
2013-07-01
... engine and sampling systems. (7) Sample emissions throughout the duty cycle. (8) Record post-test data. (9) Perform post-test procedures to verify proper operation of certain equipment and analyzers. (10... PROCEDURES Performing an Emission Test Over Specified Duty Cycles § 1065.501 Overview. (a) Use the procedures...
Code of Federal Regulations, 2012 CFR
2012-07-01
... engine and sampling systems. (7) Sample emissions throughout the duty cycle. (8) Record post-test data. (9) Perform post-test procedures to verify proper operation of certain equipment and analyzers. (10... PROCEDURES Performing an Emission Test Over Specified Duty Cycles § 1065.501 Overview. (a) Use the procedures...
DOT National Transportation Integrated Search
2005-09-01
This document describes a procedure for verifying a dynamic testing system (closed-loop servohydraulic). The procedure is divided into three general phases: (1) electronic system performance verification, (2) calibration check and overall system perf...
34 CFR 645.32 - How does the Secretary evaluate prior experience?
Code of Federal Regulations, 2010 CFR
2010-07-01
... performance under its expiring Upward Bound grant. This information includes information derived from annual performance reports, audit reports, site visit reports, project evaluation reports, and any other verifiable... project participants have demonstrated improvement in academic skills and competencies as measured by...
Development of Internet-Based Tasks for the Executive Function Performance Test.
Rand, Debbie; Lee Ben-Haim, Keren; Malka, Rachel; Portnoy, Sigal
The Executive Function Performance Test (EFPT) is a reliable and valid performance-based tool to assess executive functions (EFs). This study's objective was to develop and verify two Internet-based tasks for the EFPT. A cross-sectional study assessed the alternate-form reliability of the Internet-based bill-paying and telephone-use tasks in healthy adults and people with subacute stroke (Study 1). It also sought to establish the tasks' criterion reliability for assessing EF deficits by correlating performance with that on the Trail Making Test in five groups: healthy young adults, healthy older adults, people with subacute stroke, people with chronic stroke, and young adults with attention deficit hyperactivity disorder (Study 2). The alternative-form reliability and initial construct validity for the Internet-based bill-paying task were verified. Criterion validity was established for both tasks. The Internet-based tasks are comparable to the original EFPT tasks and can be used for assessment of EF deficits. Copyright © 2018 by the American Occupational Therapy Association, Inc.
NASA Technical Reports Server (NTRS)
Haigh, R.; Krimchansky, S. (Technical Monitor)
2000-01-01
This is the Performance Verification Report, METSAT (S/N 108) AMSU-A1 Receiver Assemblies P/N 1356429-1 S/N F05 and P/N 1356409-1 S/N F05, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A). The ATP for the AMSU-A Receiver Subsystem, AE-26002/6A, is prepared to describe in detail the configuration of the test setups and the procedures of the tests to verify that the receiver subsystem meets the specifications as required either in the AMSU-A Instrument Performance and Operation Specifications, S-480-80, or in AMSU-A Receiver Subsystem Specifications, AE-26608, derived by the Aerojet System Engineering. Test results that verify the conformance to the specifications demonstrate the acceptability of that particular receiver subsystem.
Short-term phonological memory in preschool children.
Rodrigues, Amalia; Befi-Lopes, Debora Maria
2013-01-01
The purpose of this study was to design a short-term memory test, to describe quantitative performance in typically language developing children and to verify the relationship between the non-words repetition and oral phonological measure. The participants included 136 typically language developing children aged from 3 years to 6 years and 11 months old in this study, who were evaluated. The test consisted of 40 non-words of one, two, three, and four syllables. The subjects' repetitions were transcribed and the number of right answers was calculated for each age range. The effect of age was observed in the test, as well as the effect of length, only for disyllabic non-words. The performance in the non-word repetition task showed correlation with the oral phonology measure. The test designed in this research was able to verify the short-term memory in typically language developing children and the results showed correlation between this memory and phonological performance.
The Researching on Evaluation of Automatic Voltage Control Based on Improved Zoning Methodology
NASA Astrophysics Data System (ADS)
Xiao-jun, ZHU; Ang, FU; Guang-de, DONG; Rui-miao, WANG; De-fen, ZHU
2018-03-01
According to the present serious phenomenon of increasing size and structure of power system, hierarchically structured automatic voltage control(AVC) has been the researching spot. In the paper, the reduced control model is built and the adaptive reduced control model is researched to improve the voltage control effect. The theories of HCSD, HCVS, SKC and FCM are introduced and the effect on coordinated voltage regulation caused by different zoning methodologies is also researched. The generic framework for evaluating performance of coordinated voltage regulation is built. Finally, the IEEE-96 stsyem is used to divide the network. The 2383-bus Polish system is built to verify that the selection of a zoning methodology affects not only the coordinated voltage regulation operation, but also its robustness to erroneous data and proposes a comprehensive generic framework for evaluating its performance. The New England 39-bus network is used to verify the adaptive reduced control models’ performance.
NASA Astrophysics Data System (ADS)
Mao, Mingzhi; Qian, Chen; Cao, Bingyao; Zhang, Qianwu; Song, Yingxiong; Wang, Min
2017-09-01
A digital signal process enabled dual-drive Mach-Zehnder modulator (DD-MZM)-based spectral converter is proposed and extensively investigated to realize dynamically reconfigurable and high transparent spectral conversion. As another important innovation point of the paper, to optimize the converter performance, the optimum operation conditions of the proposed converter are deduced, statistically simulated, and experimentally verified. The optimum conditions supported-converter performances are verified by detail numerical simulations and experiments in intensity-modulation and direct-detection-based network in terms of frequency detuning range-dependent conversion efficiency, strict operation transparency for user signal characteristics, impact of parasitic components on the conversion performance, as well as the converted component waveform are almost nondistortion. It is also found that the converter has the high robustness to the input signal power, optical signal-to-noise ratio variations, extinction ratio, and driving signal frequency.
NASA Astrophysics Data System (ADS)
Ye, Bo; Zhang, Wei; Sun, Zhen-jun; Guo, Lin; Deng, Chao; Chen, Ya-qi; Zhang, Hong-hai; Liu, Sheng
2015-12-01
In this paper, the authors propose rotating an external permanent magnet (EPM) to manipulate the synchronous rotation of a magnetic spiral-type wireless capsule endoscope (WCE), and the synchronous rotation of the WCE is converted to its translational motion in intestinal tract. In order to preliminarily verify the feasibility of this method, a handheld actuator (HA) controlled by micro controller unit, a magnetic spiral-type WCE and a bracket were fabricated, theoretical analysis and simulations about the control distance of this method were performed, and in ex-vivo tests were examined in porcine small intestine to verify the control distance and control performances of this method. It was demonstrated that this method showed good performances in controlling the translational motion of the magnetic spiral-type WCE, and this method has great potential to be used in clinical application.
Nonsense-mediated mRNA decay factor Upf2 exists in both the nucleoplasm and the cytoplasm
TATSUNO, TAKANORI; NAKAMURA, YUKA; MA, SHAOFU; TOMOSUGI, NAOHISA; ISHIGAKI, YASUHITO
2016-01-01
Upf2 protein predominantly localizes to the cytoplasmic fraction, and binds to the exon junction complex (EJC) on spliced mRNA. The present study aimed to determine the cellular site where the interaction between Upf2 and EJC occurs. First, the cell lysate was fractionated into the cytoplasm and nucleoplasm, and western blotting to detect levels of Upf2 protein was performed. Upf2 was clearly detected in the cytoplasm and in the nucleoplasm. Secondly, immunostaining was performed, and the majority of Upf2 was detected in the cytoplasmic perinuclear region; a small quantity of Upf2 was detected in the intranuclear region. RNase treatment of the cells reduced the Upf2 immunostained signal. The immune-purified fractions containing nuclear and cytoplasmic Upf2 also contained one of the EJC core factors, RBM8A. These results implied the existence of Upf2 in the nucleoplasm and the cytoplasm, and it appeared to be involved in the construction of the mRNA complex. In order to verify the construction of Upf2-binding EJC in the nucleoplasm, an in situ proximity ligation assay was performed with anti-Upf2 and anti-RBM8A antibodies. These results demonstrated that their interaction occurred not only in the cytoplasmic region, but also in the intranuclear region. Taken together, these results suggested that Upf2 combines with EJC in both the cytoplasmic and the intranuclear fractions, and that it is involved in mRNA metabolism in human cells. PMID:27221324
Datta, Anjan; Baidya, Subrata; Datta, Srabani; Mog, Chanda; Das, Shampa
2017-02-01
It is very important to analyze the factors which acts as obstacle in achieving 100% immunization among children. Lot Quality Assurance Sampling (LQAS) is one of the effective method to assess such barriers. To assess the full immunization coverage among 12 to 23-month old children of rural field practice area under Department of Community Medicine, Agartala Government Medical College and identify the factors for failure of full immunization. A community based cross-sectional study was conducted from November 2013 to October 2014 on children aged 12 to 23 months old of area under Mohanpur Community health centre. Using LQAS technique 330 samples were selected with multi-stage sampling, each sub-centre being one lot and two calculated to be the decision value. Data was collected using pre-designed pre-tested questionnaire during home visit and verifying immunization card and analysed by computer software SPSS version 21.0. The full immunization coverage among 12 to 23 months old children of Mohanpur area was found as 91.67%. Out of all the 22 sub-centres, 36.36% was found under performing as per pre-fixed criteria and the main reasons for failure of full immunization in those areas are unawareness of need of subsequent doses of vaccines and illness of the children. LQAS is an effective method to identify areas of under-performance even though overall full immunization coverage is high.
Doubrovsky, Anna; Scolyer, Richard A; Murali, Rajmohan; McKenzie, Paul R; Watson, Geoffrey F; Lee, C Soon; McLeod, Duncan J; McCarthy, William H; Uren, Roger F; Stretch, Jonathan R; Saw, Robyn P; Thompson, John F
2008-01-01
The use of fine needle biopsy (FNB) for the diagnosis of metastatic melanoma can lead to the early removal and treatment of metastases, reduce the frequency of unnecessary surgery, and facilitate the staging of patients enrolled in clinical trials of adjuvant therapies. In this study, the accuracy of FNB for the diagnosis of metastatic melanoma was investigated. A retrospective cohort study was performed with 2204 consecutive FNBs performed on 1416 patients known or suspected to have metastatic melanoma. Almost three-quarters (1582) of these FNBs were verified by either histopathologic diagnosis following surgical resection or clinical follow-up. FNB for metastatic melanoma was found to have an overall sensitivity of 92.1% and a specificity of 99.2%, with 69 false-negative and 5 false-positive findings identified. The sensitivity of the procedure was found to be influenced by six factors. The use of immunostains, reporting of the specimen by a cytopathologist who had reported >500 cases, lesions located in the skin and subcutis, and patients with ulcerated primary melanomas were factors associated with a significant improvement in the sensitivity of the test. However, FNBs performed in masses located in lymph nodes of the axilla and FNBs that required more than one needle pass to obtain a sample were far more likely to result in false-negative results. FNB is a rapid, accurate, and clinically useful technique for the assessment of disease status in patients with suspected metastatic melanoma.
Doubrovsky, Anna; Scolyer, Richard A.; Murali, Rajmohan; McKenzie, Paul R.; Watson, Geoffrey F.; Lee, C. Soon; McLeod, Duncan J.; McCarthy, William H.; Uren, Roger F.; Stretch, Jonathan R.; Saw, Robyn P.
2007-01-01
Background The use of fine needle biopsy (FNB) for the diagnosis of metastatic melanoma can lead to the early removal and treatment of metastases, reduce the frequency of unnecessary surgery, and facilitate the staging of patients enrolled in clinical trials of adjuvant therapies. In this study, the accuracy of FNB for the diagnosis of metastatic melanoma was investigated. Methods A retrospective cohort study was performed with 2204 consecutive FNBs performed on 1416 patients known or suspected to have metastatic melanoma. Almost three-quarters (1582) of these FNBs were verified by either histopathologic diagnosis following surgical resection or clinical follow-up. Results FNB for metastatic melanoma was found to have an overall sensitivity of 92.1% and a specificity of 99.2%, with 69 false-negative and 5 false-positive findings identified. The sensitivity of the procedure was found to be influenced by six factors. The use of immunostains, reporting of the specimen by a cytopathologist who had reported >500 cases, lesions located in the skin and subcutis, and patients with ulcerated primary melanomas were factors associated with a significant improvement in the sensitivity of the test. However, FNBs performed in masses located in lymph nodes of the axilla and FNBs that required more than one needle pass to obtain a sample were far more likely to result in false-negative results. Conclusions FNB is a rapid, accurate, and clinically useful technique for the assessment of disease status in patients with suspected metastatic melanoma. PMID:17990041
Lu, Na; Li, Tengfei; Pan, Jinjin; Ren, Xiaodong; Feng, Zuren; Miao, Hongyu
2015-05-01
Electroencephalogram (EEG) provides a non-invasive approach to measure the electrical activities of brain neurons and has long been employed for the development of brain-computer interface (BCI). For this purpose, various patterns/features of EEG data need to be extracted and associated with specific events like cue-paced motor imagery. However, this is a challenging task since EEG data are usually non-stationary time series with a low signal-to-noise ratio. In this study, we propose a novel method, called structure constrained semi-nonnegative matrix factorization (SCS-NMF), to extract the key patterns of EEG data in time domain by imposing the mean envelopes of event-related potentials (ERPs) as constraints on the semi-NMF procedure. The proposed method is applicable to general EEG time series, and the extracted temporal features by SCS-NMF can also be combined with other features in frequency domain to improve the performance of motor imagery classification. Real data experiments have been performed using the SCS-NMF approach for motor imagery classification, and the results clearly suggest the superiority of the proposed method. Comparison experiments have also been conducted. The compared methods include ICA, PCA, Semi-NMF, Wavelets, EMD and CSP, which further verified the effectivity of SCS-NMF. The SCS-NMF method could obtain better or competitive performance over the state of the art methods, which provides a novel solution for brain pattern analysis from the perspective of structure constraint. Copyright © 2015 Elsevier Ltd. All rights reserved.
Flight Motor Set 360L003 (STS-29R)
NASA Technical Reports Server (NTRS)
Riehr, Glen A.
1989-01-01
The redesigned solid rocket motor (RSRM) flight set 360L003 was launched on March 13, 1989 as part of NASA space shuttle mission STS-29R. As was the case with flight sets 360L001 and 360L002 (STS-26R and STS-27R), both motors (360L003A and 360L003B) performed in an excellent manner. Evaluation of the ground environment instrumentation measurements verified thermal model analysis data and showed agreement with predicted environmental effects. The right-hand aft field joint primary heater failed during the countdown; the secondary heater was activated and performed as designed. All other field joint heaters and aft skirt thermal conditioning systems had no anomalies. Shuttle thermal imager infrared readings compared favorably with measured ground environment instrumentation data. No thermal launch commit criteria violations occurred at any time. Evaluation of the development flight instrumentation showed exceptional propulsion performance. All ballistic parameters closely matched the predicted values and were well within the required specification levels. Girth and biaxial strain gage measurements compared closely with corresponding gages on previous flight motors, static tests, and with preflight predictions. Adequate safety factors were verified. (Some ignition transient spiking was noted in a few girth gages; the spiking was determined not to be representative of actual case behavior, but an instrumentation phenomena.) The accelerometers again measured high vibration amplitude levels during the ignition transient and the reentry Max Q phases. Postflight inspection showed that all combustion gas was contained by the insulation in the field and case-to-nozzle joints. No anomalous insulation erosion patterns were found, and the seals that did directly contain motor pressure showed no heat effects, erosion, or blowby. All anomalies identified were a result of splashdown damage, with the exception of fretting in the case field joint interference (nonsealing) surfaces and a prelaunch field joint heater failure. The disposition of all anomalies and the complete results are reported.
Peak oxygen consumption measured during the stair-climbing test in lung resection candidates.
Brunelli, Alessandro; Xiumé, Francesco; Refai, Majed; Salati, Michele; Di Nunzio, Luca; Pompili, Cecilia; Sabbatini, Armando
2010-01-01
The stair-climbing test is commonly used in the preoperative evaluation of lung resection candidates, but it is difficult to standardize and provides little physiologic information on the performance. To verify the association between the altitude and the V(O2peak) measured during the stair-climbing test. 109 consecutive candidates for lung resection performed a symptom-limited stair-climbing test with direct breath-by-breath measurement of V(O2peak) by a portable gas analyzer. Stepwise logistic regression and bootstrap analyses were used to verify the association of several perioperative variables with a V(O2peak) <15 ml/kg/min. Subsequently, multiple regression analysis was also performed to develop an equation to estimate V(O2peak) from stair-climbing parameters and other patient-related variables. 56% of patients climbing <14 m had a V(O2peak) <15 ml/kg/min, whereas 98% of those climbing >22 m had a V(O2peak) >15 ml/kg/min. The altitude reached at stair-climbing test resulted in the only significant predictor of a V(O2peak) <15 ml/kg/min after logistic regression analysis. Multiple regression analysis yielded an equation to estimate V(O2peak) factoring altitude (p < 0.0001), speed of ascent (p = 0.005) and body mass index (p = 0.0008). There was an association between altitude and V(O2peak) measured during the stair-climbing test. Most of the patients climbing more than 22 m are able to generate high values of V(O2peak) and can proceed to surgery without any additional tests. All others need to be referred for a formal cardiopulmonary exercise test. In addition, we were able to generate an equation to estimate V(O2peak), which could assist in streamlining the preoperative workup and could be used across different settings to standardize this test. Copyright (c) 2010 S. Karger AG, Basel.
Replication of Structure Findings regarding the Interpersonal Reactivity Index.
ERIC Educational Resources Information Center
Carey, John C.; And Others
1988-01-01
Attempted to verify multidimensional nature and item composition of Interpersonal Reactivity Index (IRI) subscales through factor analysis. IRI responses from 365 female clinical dieticians and dietetic interns supported contention that IRI subscales measure four discernibly different empathy dimensions. (NB)
Trust, but verify - Accuracy of clinical commercial radiation Treatment Planning Systems
NASA Astrophysics Data System (ADS)
Lehmann, J.; Kenny, J.; Lye, J.; Dunn, L.; Williams, I.
2014-03-01
Computer based Treatment Planning Systems (TPS) are used worldwide to design and calculate treatment plans for treating radiation therapy patients. TPS are generally well designed and thoroughly tested by their developers and local physicists prior to clinical use. However, the wide-reaching impact of their accuracy warrants ongoing vigilance. This work reviews the findings of the Australian national audit system and provides recommendations for checks of TPS. The Australian Clinical Dosimetry Service (ACDS) has designed and implemented a national system of audits, currently in a three year test phase. The Level III audits verify the accuracy of a beam model of a facility's TPS through a comparison of measurements with calculation at selected points in an anthropomorphic phantom. The plans are prescribed by the ACDS and all measurement equipment is brought in for independent onsite measurements. In this first version of audits, plans are comparatively simple, involving asymmetric fields, wedges and inhomogeneities. The ACDS has performed 14 Level III audits to-date. Six audits returned at least one measurement at Action Level, indicating that the measured dose differed more than 3.3% (but less than 5%) from the planned dose. Two audits failed (difference >5%). One fail was caused by a data transmission error coupled with quality assurance (QA) not being performed. The second fail was investigated and reduced to Action Level with the onsite audit team finding phantom setup at treatment a contributing factor. The Action Level results are attributed to small dose calculation deviations within the TPS, which are investigated and corrected by the facilities. Small deviations exist in clinical TPS which can add up and can combine with output variations to result in unacceptable variations. Ongoing checks and independent audits are recommended.
NASA Technical Reports Server (NTRS)
Jeng, Frank F.
2007-01-01
Development of analysis guidelines for Exploration Life Support (ELS) technology tests was completed. The guidelines were developed based on analysis experiences gained from supporting Environmental Control and Life Support System (ECLSS) technology development in air revitalization systems and water recovery systems. Analyses are vital during all three phases of the ELS technology test: pre-test, during test and post test. Pre-test analyses of a test system help define hardware components, predict system and component performances, required test duration, sampling frequencies of operation parameters, etc. Analyses conducted during tests could verify the consistency of all the measurements and the performance of the test system. Post test analyses are an essential part of the test task. Results of post test analyses are an important factor in judging whether the technology development is a successful one. In addition, development of a rigorous model for a test system is an important objective of any new technology development. Test data analyses, especially post test data analyses, serve to verify the model. Test analyses have supported development of many ECLSS technologies. Some test analysis tasks in ECLSS technology development are listed in the Appendix. To have effective analysis support for ECLSS technology tests, analysis guidelines would be a useful tool. These test guidelines were developed based on experiences gained through previous analysis support of various ECLSS technology tests. A comment on analysis from an experienced NASA ECLSS manager (1) follows: "Bad analysis was one that bent the test to prove that the analysis was right to begin with. Good analysis was one that directed where the testing should go and also bridged the gap between the reality of the test facility and what was expected on orbit."
Martin, Shelby; Wagner, Jesse; Lupulescu-Mann, Nicoleta; Ramsey, Katrina; Cohen, Aaron; Graven, Peter; Weiskopf, Nicole G; Dorr, David A
2017-08-02
To measure variation among four different Electronic Health Record (EHR) system documentation locations versus 'gold standard' manual chart review for risk stratification in patients with multiple chronic illnesses. Adults seen in primary care with EHR evidence of at least one of 13 conditions were included. EHRs were manually reviewed to determine presence of active diagnoses, and risk scores were calculated using three different methodologies and five EHR documentation locations. Claims data were used to assess cost and utilization for the following year. Descriptive and diagnostic statistics were calculated for each EHR location. Criterion validity testing compared the gold standard verified diagnoses versus other EHR locations and risk scores in predicting future cost and utilization. Nine hundred patients had 2,179 probable diagnoses. About 70% of the diagnoses from the EHR were verified by gold standard. For a subset of patients having baseline and prediction year data (n=750), modeling showed that the gold standard was the best predictor of outcomes on average for a subset of patients that had these data. However, combining all data sources together had nearly equivalent performance for prediction as the gold standard. EHR data locations were inaccurate 30% of the time, leading to improvement in overall modeling from a gold standard from chart review for individual diagnoses. However, the impact on identification of the highest risk patients was minor, and combining data from different EHR locations was equivalent to gold standard performance. The reviewer's ability to identify a diagnosis as correct was influenced by a variety of factors, including completeness, temporality, and perceived accuracy of chart data.
Azadi, Sama; Karimi-Jashni, Ayoub
2016-02-01
Predicting the mass of solid waste generation plays an important role in integrated solid waste management plans. In this study, the performance of two predictive models, Artificial Neural Network (ANN) and Multiple Linear Regression (MLR) was verified to predict mean Seasonal Municipal Solid Waste Generation (SMSWG) rate. The accuracy of the proposed models is illustrated through a case study of 20 cities located in Fars Province, Iran. Four performance measures, MAE, MAPE, RMSE and R were used to evaluate the performance of these models. The MLR, as a conventional model, showed poor prediction performance. On the other hand, the results indicated that the ANN model, as a non-linear model, has a higher predictive accuracy when it comes to prediction of the mean SMSWG rate. As a result, in order to develop a more cost-effective strategy for waste management in the future, the ANN model could be used to predict the mean SMSWG rate. Copyright © 2015 Elsevier Ltd. All rights reserved.
Summary of EM launcher experiments performed at LLNL
NASA Astrophysics Data System (ADS)
Hawke, R. S.; Nellis, W. J.; Newman, G. H.; Rego, J.; Susoeff, A. R.
1986-11-01
Performance results for three railguns are summarized. The system used a helium gas-driven injector and railgun launcher to accelerate 1- and 4-g polycarbonate projectiles intact up to 6.6 and 3.0 km/sc, respectively. A 625 kJ capacitor bank powered the railgun, and an adjustable inductor provided pulse shaping and peak current control. Operation in hard and soft vacuum was reliably achieved. The diagnostic system measured the projectile position and launch velocity, verified that the projectile was launched intact in the desired direction, and identified system components where improvements could enhance performance. Flash X-ray radiography measured velocity and verified that projectiles were intact. Pre-launch projectile travel along the axis of the launcher without tilt was recorded with flash radiographs and impact impressions or holes in witness plates. The sysem performed as expected up to 4-5 km/sec but below expectations at higher velocities. Diagnostics suggest that the decreased performance was probably cuased by the restriking of a second arc in the breech of the railgun, which shunted the current from the propulsive arc.
Odontomas and Supernumerary Teeth: Is There a Common Origin?
Pippi, Roberto
2014-01-01
The aim of the present work is to analyze all scientific evidence to verify whether similarities supporting a unified explanation for odontomas and supernumerary teeth exist. A literature search was first conducted for epidemiologic studies indexed by PubMed, to verify their worldwide incidence. The analysis of the literature data shows some interesting similarities between odontomas and supernumerary teeth concerning their topographic distribution and pathologic manifestations. There is also some indication of common genetic and immuno-histochemical factors. Although from a nosological point of view, odontomas and supernumeraries are classified as distinct entities, they seem to be the expression of the same pathologic process, either malformative or hamartomatous. PMID:25419174
10 CFR 72.160 - Licensee and certificate holder inspection.
Code of Federal Regulations, 2011 CFR
2011-01-01
... WASTE Quality Assurance § 72.160 Licensee and certificate holder inspection. The licensee, applicant for... inspection of activities affecting quality by or for the organization performing the activity to verify.... Examinations, measurements, or tests of material or products processed must be performed for each work...
10 CFR 72.160 - Licensee and certificate holder inspection.
Code of Federal Regulations, 2010 CFR
2010-01-01
... WASTE Quality Assurance § 72.160 Licensee and certificate holder inspection. The licensee, applicant for... inspection of activities affecting quality by or for the organization performing the activity to verify.... Examinations, measurements, or tests of material or products processed must be performed for each work...
10 CFR 72.160 - Licensee and certificate holder inspection.
Code of Federal Regulations, 2013 CFR
2013-01-01
... WASTE Quality Assurance § 72.160 Licensee and certificate holder inspection. The licensee, applicant for... inspection of activities affecting quality by or for the organization performing the activity to verify.... Examinations, measurements, or tests of material or products processed must be performed for each work...
10 CFR 72.160 - Licensee and certificate holder inspection.
Code of Federal Regulations, 2012 CFR
2012-01-01
... WASTE Quality Assurance § 72.160 Licensee and certificate holder inspection. The licensee, applicant for... inspection of activities affecting quality by or for the organization performing the activity to verify.... Examinations, measurements, or tests of material or products processed must be performed for each work...
10 CFR 72.160 - Licensee and certificate holder inspection.
Code of Federal Regulations, 2014 CFR
2014-01-01
... WASTE Quality Assurance § 72.160 Licensee and certificate holder inspection. The licensee, applicant for... inspection of activities affecting quality by or for the organization performing the activity to verify.... Examinations, measurements, or tests of material or products processed must be performed for each work...
ERIC Educational Resources Information Center
Jackson, Paul R.
1972-01-01
The probabilities of certain English football teams winning different playoffs are determined. In each case, a mathematical model is fitted to the observed data, assumptions are verified, and the calculations performed. (LS)
Scale Factor Study for 1:30 Local Scour Model
2016-08-01
railway crossing on the Santa Ana River near Corona , CA. Data from the scale factor study provide an adjustment for applying documented scour...upstream and downstream of the test section respectively. Discharge into the model came from three recirculation pumps with a total capacity of ERDC...upstream baffle blocks. The total discharge was measured by reading the differential from a manometer across a venturi meter and verified with a total
Prospective safety performance evaluation on construction sites.
Wu, Xianguo; Liu, Qian; Zhang, Limao; Skibniewski, Miroslaw J; Wang, Yanhong
2015-05-01
This paper presents a systematic Structural Equation Modeling (SEM) based approach for Prospective Safety Performance Evaluation (PSPE) on construction sites, with causal relationships and interactions between enablers and the goals of PSPE taken into account. According to a sample of 450 valid questionnaire surveys from 30 Chinese construction enterprises, a SEM model with 26 items included for PSPE in the context of Chinese construction industry is established and then verified through the goodness-of-fit test. Three typical types of construction enterprises, namely the state-owned enterprise, private enterprise and Sino-foreign joint venture, are selected as samples to measure the level of safety performance given the enterprise scale, ownership and business strategy are different. Results provide a full understanding of safety performance practice in the construction industry, and indicate that the level of overall safety performance situation on working sites is rated at least a level of III (Fair) or above. This phenomenon can be explained that the construction industry has gradually matured with the norms, and construction enterprises should improve the level of safety performance as not to be eliminated from the government-led construction industry. The differences existing in the safety performance practice regarding different construction enterprise categories are compared and analyzed according to evaluation results. This research provides insights into cause-effect relationships among safety performance factors and goals, which, in turn, can facilitate the improvement of high safety performance in the construction industry. Copyright © 2015 Elsevier Ltd. All rights reserved.
Vertical nanowire heterojunction devices based on a clean Si/Ge interface.
Chen, Lin; Fung, Wayne Y; Lu, Wei
2013-01-01
Different vertical nanowire heterojunction devices were fabricated and tested based on vertical Ge nanowires grown epitaxially at low temperatures on (111) Si substrates with a sharp and clean Si/Ge interface. The nearly ideal Si/Ge heterojuctions with controlled and abrupt doping profiles were verified through material analysis and electrical characterizations. In the nSi/pGe heterojunction diode, an ideality factor of 1.16, subpicoampere reverse saturation current, and rectifying ratio of 10(6) were obtained, while the n+Si/p+Ge structure leads to Esaki tunnel diodes with a high peak tunneling current of 4.57 kA/cm(2) and negative differential resistance at room temperature. The large valence band discontinuity between the Ge and Si in the nanowire heterojunctions was further verified in the p+Si/pGe structure, which shows a rectifying behavior instead of an Ohmic contact and raises an important issue in making Ohmic contacts to heterogeneously integrated materials. A raised Si/Ge structure was further developed using a self-aligned etch process, allowing greater freedom in device design for applications such as the tunneling field-effect transistor (TFET). All measurement data can be well-explained and fitted with theoretical models with known bulk properties, suggesting that the Si/Ge nanowire system offers a very clean heterojunction interface with low defect density, and holds great potential as a platform for future high-density and high-performance electronics.
Amir, Ofra; Amir, Dor; Shahar, Yuval; Hart, Yuval; Gal, Kobi
2018-01-01
Demonstrability-the extent to which group members can recognize a correct solution to a problem-has a significant effect on group performance. However, the interplay between group size, demonstrability and performance is not well understood. This paper addresses these gaps by studying the joint effect of two factors-the difficulty of solving a problem and the difficulty of verifying the correctness of a solution-on the ability of groups of varying sizes to converge to correct solutions. Our empirical investigations use problem instances from different computational complexity classes, NP-Complete (NPC) and PSPACE-complete (PSC), that exhibit similar solution difficulty but differ in verification difficulty. Our study focuses on nominal groups to isolate the effect of problem complexity on performance. We show that NPC problems have higher demonstrability than PSC problems: participants were significantly more likely to recognize correct and incorrect solutions for NPC problems than for PSC problems. We further show that increasing the group size can actually decrease group performance for some problems of low demonstrability. We analytically derive the boundary that distinguishes these problems from others for which group performance monotonically improves with group size. These findings increase our understanding of the mechanisms that underlie group problem-solving processes, and can inform the design of systems and processes that would better facilitate collective decision-making.
Automated survey of 8000 plan checks at eight facilities.
Halabi, Tarek; Lu, Hsiao-Ming; Bernard, Damian A; Chu, James C H; Kirk, Michael C; Hamilton, Russell J; Lei, Yu; Driewer, Joseph
2016-09-01
To identify policy and system related weaknesses in treatment planning and plan check work-flows. The authors' web deployed plan check automation solution, PlanCheck, which works with all major planning and record and verify systems (demonstrated here for mosaiq only), allows them to compute violation rates for a large number of plan checks across many facilities without requiring the manual data entry involved with incident filings. Workflows and failure modes are heavily influenced by the type of record and verify system used. Rather than tackle multiple record and verify systems at once, the authors restricted the present survey to mosaiq facilities. Violations were investigated by sending inquiries to physicists running the program. Frequent violations included inadequate tracking in the record and verify system of total and prescription doses. Infrequent violations included incorrect setting of patient orientation in the record and verify system. Peaks in the distribution, over facilities, of violation frequencies pointed to suboptimal policies at some of these facilities. Correspondence with physicists often revealed incomplete knowledge of settings at their facility necessary to perform thorough plan checks. The survey leads to the identification of specific and important policy and system deficiencies that include: suboptimal timing of initial plan checks, lack of communication or agreement on conventions surrounding prescription definitions, and lack of automation in the transfer of some parameters.
Replicating the Z iron opacity experiments on the NIF
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perry, T. S.; Heeter, R. F.; Opachich, Y. P.
Here, X-ray opacity is a crucial factor of all radiation-hydrodynamics calculations, yet it is one of the least validated of the material properties in the simulation codes. Recent opacity experiments at the Sandia Z-machine have shown up to factors of two discrepancies between theory and experiment, casting doubt on the validity of the opacity models. Therefore, a new experimental opacity platform is being developed on the National Ignition Facility (NIF) not only to verify the Z-machine experimental results but also to extend the experiments to other temperatures and densities. The first experiments will be directed towards measuring the opacity ofmore » iron at a temperature of ~160 eV and an electron density of ~7 x 10 21 cm -3. Preliminary experiments on NIF have demonstrated the ability to create a sufficiently bright point backlighter using an imploding plastic capsule and also a hohlraum that can heat the opacity sample to the desired conditions. The first of these iron opacity experiments is expected to be performed in 2017.« less
Abdelkader, Noha F; Safar, Marwa M; Salem, Hesham A
2016-03-01
The recent emergence of ursodeoxycholic acid (UDCA) as a contender in modifying neurotoxicity in human dopaminergic cells as well as its recognized anti-apoptotic and anti-inflammatory potentials in various hepatic pathologies raised impetus in investigating its anti-parkinsonian effect in rat rotenone model. UDCA prominently improved motor performance in the open field test and halted the decline in the striatal dopamine content. Meanwhile, it improved mitochondrial function as verified by elevation of ATP associated with preservation of mitochondrial integrity as portrayed in the electron microscope examination. In addition, through its anti-inflammatory potential, UDCA reduced the rotenone-induced nuclear factor-κB expression and tumor necrosis factor alpha level. Furthermore, UDCA amended alterations in Bax and Bcl-2 and reduced the activities of caspase-8, caspase-9, and caspase-3, indicating that it suppressed rotenone-induced apoptosis via modulating both intrinsic and extrinsic pathways. In conclusion, UDCA can be introduced as a novel approach for the management of Parkinson's disease via anti-apoptotic and anti-inflammatory mechanisms. These effects are probably linked to dopamine synthesis and mitochondrial regulation.
A new principle technic for the transformation from frequency domain to time domain
NASA Astrophysics Data System (ADS)
Gao, Ben-Qing
2017-03-01
A principle technic for the transformation from frequency domain to time domain is presented. Firstly, a special type of frequency domain transcendental equation is obtained for an expected frequency domain parameter which is a rational or irrational fraction expression. Secondly, the inverse Laplace transformation is performed. When the two time-domain factors corresponding to the two frequency domain factors at two sides of frequency domain transcendental equation are known quantities, a time domain transcendental equation is reached. At last, the expected time domain parameter corresponding to the expected frequency domain parameter can be solved by the inverse convolution process. Proceeding from rational or irrational fraction expression, all solving process is provided. In the meantime, the property of time domain sequence is analyzed and the strategy for choosing the parameter values is described. Numerical examples are presented to verify the proposed theory and technic. Except for rational or irrational fraction expressions, examples of complex relative permittivity of water and plasma are used as verification method. The principle method proposed in the paper can easily solve problems which are difficult to be solved by Laplace transformation.
Neural network approach to proximity effect corrections in electron-beam lithography
NASA Astrophysics Data System (ADS)
Frye, Robert C.; Cummings, Kevin D.; Rietman, Edward A.
1990-05-01
The proximity effect, caused by electron beam backscattering during resist exposure, is an important concern in writing submicron features. It can be compensated by appropriate local changes in the incident beam dose, but computation of the optimal correction usually requires a prohibitively long time. We present an example of such a computation on a small test pattern, which we performed by an iterative method. We then used this solution as a training set for an adaptive neural network. After training, the network computed the same correction as the iterative method, but in a much shorter time. Correcting the image with a software based neural network resulted in a decrease in the computation time by a factor of 30, and a hardware based network enhanced the computation speed by more than a factor of 1000. Both methods had an acceptably small error of 0.5% compared to the results of the iterative computation. Additionally, we verified that the neural network correctly generalized the solution of the problem to include patterns not contained in its training set.
Rabinowicz, Noa; Mangala, Lingegowda S.; Brown, Kevin R.; Checa-Rodriguez, Cintia; Castiel, Asher; Moskovich, Oren; Zarfati, Giulia; Trakhtenbrot, Luba; Levy-Barda, Adva; Jiang, Dahai; Rodriguez-Aguayo, Cristian; Pradeep, Sunila; van Praag, Yael; Lopez-Berestein, Gabriel; David, Ahuvit; Novikov, Ilya; Huertas, Pablo; Rottapel, Robert; Sood, Anil K.; Izraeli, Shai
2017-01-01
Advanced ovarian cancer is an incurable disease. Thus, novel therapies are required. We wished to identify new therapeutic targets for ovarian cancer. ShRNA screen performed in 42 ovarian cancer cell lines identified the centriolar replication factor STIL as an essential gene for ovarian cancer cells. This was verified in-vivo in orthotopic human ovarian cancer mouse models. STIL depletion by administration of siRNA in neutral liposomes resulted in robust anti-tumor effect that was further enhanced in combination with cisplatin. Consistent with this finding, STIL depletion enhanced the extent of DNA double strand breaks caused by DNA damaging agents. This was associated with centrosomal depletion, ongoing genomic instability and enhanced formation of micronuclei. Interestingly, the ongoing DNA damage was not associated with reduced DNA repair. Indeed, we observed that depletion of STIL enhanced canonical homologous recombination repair and increased BRCA1 and RAD51 foci in response to DNA double strand breaks. Thus, inhibition of STIL significantly enhances the efficacy of DNA damaging chemotherapeutic drugs in treatment of ovarian cancer. PMID:28423708
Assessment of Carrying Capacity of Timber Element Using SBRA Method
NASA Astrophysics Data System (ADS)
Kraus, Michal
2017-10-01
Wood as a building material has a significant perspective in the context of nonrenewable energy sources and production of greenhouse gas emissions. The subject of this paper is to verify the carrying capacity of the timber element using the probabilistic method Simulation Based Reliability Assessment (SBRA). The simulation is performed for one million cycles. Key factors decreasing the strength of wooden material at the time include the duration of the loads, and combinations thereof. Inconsiderable factor affecting the strength of wood is also the humidity. Continuous beam with three fields (length 15 m, glued laminated timber, and strength class GL 36 according to the DIN EN 1194) is placed in an environment with a thermal-humidity regime of the 2nd class according to the EC 5. Average life of carrying timber structure is estimated to be 50 years. The simulation results show that there is no risk of failure of wood during the first year. The probability of failure is common in the 10 years of its life. Then, wooden element already meets only a reduced level of reliability.
Replicating the Z iron opacity experiments on the NIF
Perry, T. S.; Heeter, R. F.; Opachich, Y. P.; ...
2017-05-12
Here, X-ray opacity is a crucial factor of all radiation-hydrodynamics calculations, yet it is one of the least validated of the material properties in the simulation codes. Recent opacity experiments at the Sandia Z-machine have shown up to factors of two discrepancies between theory and experiment, casting doubt on the validity of the opacity models. Therefore, a new experimental opacity platform is being developed on the National Ignition Facility (NIF) not only to verify the Z-machine experimental results but also to extend the experiments to other temperatures and densities. The first experiments will be directed towards measuring the opacity ofmore » iron at a temperature of ~160 eV and an electron density of ~7 x 10 21 cm -3. Preliminary experiments on NIF have demonstrated the ability to create a sufficiently bright point backlighter using an imploding plastic capsule and also a hohlraum that can heat the opacity sample to the desired conditions. The first of these iron opacity experiments is expected to be performed in 2017.« less
Rabinowicz, Noa; Mangala, Lingegowda S; Brown, Kevin R; Checa-Rodriguez, Cintia; Castiel, Asher; Moskovich, Oren; Zarfati, Giulia; Trakhtenbrot, Luba; Levy-Barda, Adva; Jiang, Dahai; Rodriguez-Aguayo, Cristian; Pradeep, Sunila; van Praag, Yael; Lopez-Berestein, Gabriel; David, Ahuvit; Novikov, Ilya; Huertas, Pablo; Rottapel, Robert; Sood, Anil K; Izraeli, Shai
2017-04-18
Advanced ovarian cancer is an incurable disease. Thus, novel therapies are required. We wished to identify new therapeutic targets for ovarian cancer. ShRNA screen performed in 42 ovarian cancer cell lines identified the centriolar replication factor STIL as an essential gene for ovarian cancer cells. This was verified in-vivo in orthotopic human ovarian cancer mouse models. STIL depletion by administration of siRNA in neutral liposomes resulted in robust anti-tumor effect that was further enhanced in combination with cisplatin. Consistent with this finding, STIL depletion enhanced the extent of DNA double strand breaks caused by DNA damaging agents. This was associated with centrosomal depletion, ongoing genomic instability and enhanced formation of micronuclei. Interestingly, the ongoing DNA damage was not associated with reduced DNA repair. Indeed, we observed that depletion of STIL enhanced canonical homologous recombination repair and increased BRCA1 and RAD51 foci in response to DNA double strand breaks. Thus, inhibition of STIL significantly enhances the efficacy of DNA damaging chemotherapeutic drugs in treatment of ovarian cancer.
Effect of Mild Acid on Gene Expression in Staphylococcus aureus
Weinrick, Brian; Dunman, Paul M.; McAleese, Fionnuala; Murphy, Ellen; Projan, Steven J.; Fang, Yuan; Novick, Richard P.
2004-01-01
During staphylococcal growth in glucose-supplemented medium, the pH of a culture starting near neutrality typically decreases by about 2 units due to the fermentation of glucose. Many species can comfortably tolerate the resulting mildly acidic conditions (pH, ∼5.5) by mounting a cellular response, which serves to defend the intracellular pH and, in principle, to modify gene expression for optimal performance in a mildly acidic infection site. In this report, we show that changes in staphylococcal gene expression formerly thought to represent a glucose effect are largely the result of declining pH. We examine the cellular response to mild acid by microarray analysis and define the affected gene set as the mild acid stimulon. Many of the genes encoding extracellular virulence factors are affected, as are genes involved in regulation of virulence factor gene expression, transport of sugars and peptides, intermediary metabolism, and pH homeostasis. Key results are verified by gene fusion and Northern blot hybridization analyses. The results point to, but do not define, possible regulatory pathways by which the organism senses and responds to a pH stimulus. PMID:15576791
NASA Astrophysics Data System (ADS)
Zhu, Linhe; Zhao, Hongyong
2017-07-01
A series of online rumours have seriously influenced the normal production and living of people. This paper aims to study the combined impact of psychological factor, propagation delay, network topology and control strategy on rumour diffusion over the online social networks. Based on an online social network, which is seen as a scale-free network, we model the spread of rumours by using a delayed SIS (Susceptible and Infected) epidemic-like model with consideration of psychological factor and network topology. First, through theoretical analysis, we illustrate the boundedness of the density of rumour-susceptible individuals and rumour-infected individuals. Second, we obtain the basic reproduction number R0 and prove the stability of the non-rumour equilibrium point and the rumour-spreading equilibrium point. Third, control strategies, such as uniform immunisation control, proportional immunisation control, targeted immunisation control and optimum control, are put forward to restrain rumour diffusion. Meanwhile, we have compared the differences of these control strategies. Finally, some representative numerical simulations are performed to verify the theoretical analysis results.
Design of flat pneumatic artificial muscles
NASA Astrophysics Data System (ADS)
Wirekoh, Jackson; Park, Yong-Lae
2017-03-01
Pneumatic artificial muscles (PAMs) have gained wide use in the field of robotics due to their ability to generate linear forces and motions with a simple mechanism, while remaining lightweight and compact. However, PAMs are limited by their traditional cylindrical form factors, which must increase radially to improve contraction force generation. Additionally, this form factor results in overly complicated fabrication processes when embedded fibers and sensor elements are required to provide efficient actuation and control of the PAMs while minimizing the bulkiness of the overall robotic system. In order to overcome these limitations, a flat two-dimensional PAM capable of being fabricated using a simple layered manufacturing process was created. Furthermore, a theoretical model was developed using Von Karman’s formulation for large deformations and the energy methods. Experimental characterizations of two different types of PAMs, a single-cell unit and a multi-cell unit, were performed to measure the maximum contraction lengths and forces at input pressures ranging from 0 to 150 kPa. Experimental data were then used to verify the fidelity of the theoretical model.
MPRS (URBOT) commercialization
NASA Astrophysics Data System (ADS)
Ciccimaro, Donny; Baker, William; Hamilton, Ian; Heikkila, Leif; Renick, Joel
2003-09-01
The Man Portable Robotic System (MPRS) project objective was to build and deliver hardened robotic systems to the U.S. Army"s 10 Mountain Division in Fort Drum, New York. The system, specifically designed for tunnel and sewer reconnaissance, was equipped with visual and audio sensors that allowed the Army engineers to detect trip wires and booby traps before personnel entered a potentially hostile environment. The MPRS system has shown to be useful in government and military supported field exercises, but the system has yet to reach the hands of civilian users. Potential users in Law Enforcement and Border Patrol have shown a strong interest in the system, but robotic costs were thought to be prohibitive for law enforcement budgets. Through the Center for Commercialization of Advanced Technology (CCAT) program, an attempt will be made to commercialize the MPRS. This included a detailed market analysis performed to verify the market viability of the technologies. Hence, the first step in this phase is to fully define the marketability of proposed technologies in terms of actual market size, pricing and cost factors, competitive risks and/or advantages, and other key factors used to develop marketing and business plans.
Region-specific S-wave attenuation for earthquakes in northwestern Iran
NASA Astrophysics Data System (ADS)
Heidari, Reza; Mirzaei, Noorbakhsh
2017-11-01
In this study, continuous wavelet transform is applied to estimate the frequency-dependent quality factor of shear waves, Q S , in northwestern Iran. The dataset used in this study includes velocigrams of more than 50 events with magnitudes between 4.0 and 6.5, which have occurred in the study area. The CWT-based method shows a high-resolution technique for the estimation of S-wave frequency-dependent attenuation. The quality factor values are determined in the form of a power law as Q S ( f) = (147 ± 16) f 0.71 ± 0.02 and (126 ± 12) f 0.73 ± 0.02 for vertical and horizontal components, respectively, where f is between 0.9 and 12 Hz. Furthermore, in order to verify the reliability of the suggested Q S estimator method, an additional test is performed by using accelerograms of Ahar-Varzaghan dual earthquakes on August 11, 2012, of moment magnitudes 6.4 and 6.3 and their aftershocks. Results indicate that the estimated Q S values from CWT-based method are not very sensitive to the numbers and types of waveforms used (velocity or acceleration).
Tengher-Barna, Iulia; Hequet, Delphine; Reboul-Marty, Jeanne; Frassati-Biaggi, Annonciade; Seince, Nathalie; Rodrigues-Faure, Anabela; Uzan, Michèle; Ziol, Marianne
2009-02-01
Margin resection status is a major risk factor for the development of local recurrence in breast conservation therapy for carcinoma. Tumor bed excision sent as separate orientated cavity margins represents a tool to verify the completeness of the carcinoma resection. We aimed to (1) determine the prevalence of positive cavity margin and its influence on subsequent surgical treatment and (2) identify potential predictive factors for positive cavity margins. From 2003 to 2006, 107 (57 years; 30-88) consecutive patients who underwent a lumpectomy for carcinoma with four orientated cavity margins for carcinoma were selected. Preoperative clinical, radiological and histological data, perioperative macroscopic characteristics and definitive histological analysis results were recorded. Lumpectomy or cavity margins were considered as positive when the distance from carcinoma to the margin was less than or equal to 3 mm. Histological examination of cavity margins showed carcinoma in 38 patients (35%), therefore modifying subsequent surgical therapy in 33 cases. Examination of the cavity margins led (1) to avoiding surgical re-excision in 20 cases (lumpectomy margins were positive and the cavity margins negative), (2) to performing a mastectomy or a re-excision in 13 cases (carcinoma was detected in the cavity margins although the lumpectomy margins were negative or tumor size was superior to 3 cm). Between preoperative and perioperative parameters, US scan and macroscopic size of the tumor were predictive factors for positive cavity margins whereas characteristics of the carcinoma determined on biopsy samples and macroscopic status of the lumpectomy margins were not. Our study confirms that the systematic practice of cavity margin resection avoids surgical re-excision and reduces the likelihood of underestimating the extent of the tumor.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hugo, Jacques
The software application is called "HFE-Trace". This is an integrated method and tool for the management of Human Factors Engineering analyses and related data. Its primary purpose is to support the coherent and consistent application of the nuclear industry's best practices for human factors engineering work. The software is a custom Microsoft® Access® application. The application is used (in conjunction with other tools such as spreadsheets, checklists and normal documents where necessary) to collect data on the design of a new nuclear power plant from subject matter experts and other sources. This information is then used to identify potential systemmore » and functional breakdowns of the intended power plant design. This information is expanded by developing extensive descriptions of all functions, as well as system performance parameters, operating limits and constraints, and operational conditions. Once these have been verified, the human factors elements are added to each function, including intended operator role, function allocation considerations, prohibited actions, primary task categories, and primary work station. In addition, the application includes a computational method to assess a number of factors such as system and process complexity, workload, environmental conditions, procedures, regulations, etc.) that may shape operator performance. This is a unique methodology based upon principles described in NUREG/CR-3331 ("A methodology for allocating nuclear power plant control functions to human or automatic control") and it results in a semi-quantified allocation of functions to three or more levels of automation for a conceptual automation system. The aggregate of all this information is then linked to the Task Analysis section of the application where the existing information on all operator functions is transformed into task information and ultimately into design requirements for Human-System Interfaces and Control Rooms. This final step includes assessment of methods to prevent potential operator errors.« less
Singh, Narendra P; Singh, Udai P; Nagarkatti, Prakash S; Nagarkatti, Mitzi
2012-11-01
Prenatal exposure to diethylstilbestrol (DES) is known to cause altered immune functions and increased susceptibility to autoimmune disease in humans. In the current study, we investigated the effect of prenatal exposure to DES on thymocyte differentiation involving apoptotic pathways. Prenatal DES exposure caused thymic atrophy, apoptosis, and up-regulation of Fas and Fas ligand (FasL) expression in thymocytes. To examine the mechanism underlying DES-mediated regulation of Fas and FasL, we performed luciferase assays using T cells transfected with luciferase reporter constructs containing full-length Fas or FasL promoters. There was significant luciferase induction in the presence of Fas or FasL promoters after DES exposure. Further analysis demonstrated the presence of several cis-regulatory motifs on both Fas and FasL promoters. When DES-induced transcription factors were analyzed, estrogen receptor element (ERE), nuclear factor κB (NF-κB), nuclear factor of activated T cells (NF-AT), and activator protein-1 motifs on the Fas promoter, as well as ERE, NF-κB, and NF-AT motifs on the FasL promoter, showed binding affinity with the transcription factors. Electrophoretic mobility-shift assays were performed to verify the binding affinity of cis-regulatory motifs of Fas or FasL promoters with transcription factors. There was shift in mobility of probes (ERE or NF-κB2) of both Fas and FasL in the presence of nuclear proteins from DES-treated cells, and the shift was specific to DES because these probes failed to shift their mobility in the presence of nuclear proteins from vehicle-treated cells. Together, the current study demonstrates that prenatal exposure to DES triggers significant alterations in apoptotic molecules expressed on thymocytes, which may affect T-cell differentiation and cause long-term effects on the immune functions.
Singh, Narendra P.; Singh, Udai P.; Nagarkatti, Prakash S.
2012-01-01
Prenatal exposure to diethylstilbestrol (DES) is known to cause altered immune functions and increased susceptibility to autoimmune disease in humans. In the current study, we investigated the effect of prenatal exposure to DES on thymocyte differentiation involving apoptotic pathways. Prenatal DES exposure caused thymic atrophy, apoptosis, and up-regulation of Fas and Fas ligand (FasL) expression in thymocytes. To examine the mechanism underlying DES-mediated regulation of Fas and FasL, we performed luciferase assays using T cells transfected with luciferase reporter constructs containing full-length Fas or FasL promoters. There was significant luciferase induction in the presence of Fas or FasL promoters after DES exposure. Further analysis demonstrated the presence of several cis-regulatory motifs on both Fas and FasL promoters. When DES-induced transcription factors were analyzed, estrogen receptor element (ERE), nuclear factor κB (NF-κB), nuclear factor of activated T cells (NF-AT), and activator protein-1 motifs on the Fas promoter, as well as ERE, NF-κB, and NF-AT motifs on the FasL promoter, showed binding affinity with the transcription factors. Electrophoretic mobility-shift assays were performed to verify the binding affinity of cis-regulatory motifs of Fas or FasL promoters with transcription factors. There was shift in mobility of probes (ERE or NF-κB2) of both Fas and FasL in the presence of nuclear proteins from DES-treated cells, and the shift was specific to DES because these probes failed to shift their mobility in the presence of nuclear proteins from vehicle-treated cells. Together, the current study demonstrates that prenatal exposure to DES triggers significant alterations in apoptotic molecules expressed on thymocytes, which may affect T-cell differentiation and cause long-term effects on the immune functions. PMID:22888145
A Magnifying Glass for Virtual Imaging of Subwavelength Resolution by Transformation Optics.
Sun, Fei; Guo, Shuwei; Liu, Yichao; He, Sailing
2018-06-14
Traditional magnifying glasses can give magnified virtual images with diffraction-limited resolution, that is, detailed information is lost. Here, a novel magnifying glass by transformation optics, referred to as a "superresolution magnifying glass" (SMG) is designed, which can produce magnified virtual images with a predetermined magnification factor and resolve subwavelength details (i.e., light sources with subwavelength distances can be resolved). Based on theoretical calculations and reductions, a metallic plate structure to produce the reduced SMG in microwave frequencies, which gives good performance verified by both numerical simulations and experimental results, is proposed and realized. The function of SMG is to create a superresolution virtual image, unlike traditional superresolution imaging devices that create real images. The proposed SMG will create a new branch of superresolution imaging technology. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Axially grooved heat pipe study
NASA Technical Reports Server (NTRS)
1977-01-01
A technology evaluation study on axially grooved heat pipes is presented. The state-of-the-art is reviewed and present and future requirements are identified. Analytical models, the Groove Analysis Program (GAP) and a closed form solution, were developed to facilitate parametric performance evaluations. GAP provides a numerical solution of the differential equations which govern the hydrodynamic flow. The model accounts for liquid recession, liquid/vapor shear interaction, puddle flow as well as laminar and turbulent vapor flow conditions. The closed form solution was developed to reduce computation time and complexity in parametric evaluations. It is applicable to laminar and ideal charge conditions, liquid/vapor shear interaction, and an empirical liquid flow factor which accounts for groove geometry and liquid recession effects. The validity of the closed form solution is verified by comparison with GAP predictions and measured data.
Investigation of transient thermal dissipation in thinned LSI for advanced packaging
NASA Astrophysics Data System (ADS)
Araga, Yuuki; Shimamoto, Haruo; Melamed, Samson; Kikuchi, Katsuya; Aoyagi, Masahiro
2018-04-01
Thinning of LSI is necessary for superior form factor and performance in dense cutting-edge packaging technologies. At the same time, degradation of thermal characteristics caused by the steep thermal gradient on LSIs with thinned base silicon is a concern. To manage a thermal environment in advanced packages, thermal characteristics of the thinned LSIs must be clarified. In this study, static and dynamic thermal dissipations were analyzed before and after thinning silicon to determine variations of thermal characteristics in thinned LSI. Measurement results revealed that silicon thinning affects dynamic thermal characteristics as well as static one. The transient variations of thermal characteristics of thinned LSI are precisely verified by analysis using an equivalent model based on the thermal network method. The results of analysis suggest that transient thermal characteristics can be easily estimated by employing the equivalent model.
Manufacturing of ArF chromeless hard shifter for 65-nm technology
NASA Astrophysics Data System (ADS)
Park, Keun-Taek; Dieu, Laurent; Hughes, Greg P.; Green, Kent G.; Croffie, Ebo H.; Taravade, Kunal N.
2003-12-01
For logic design, Chrome-less Phase Shift Mask is one of the possible solutions for defining small geometry with low MEF (mask enhancement factor) for the 65nm node. There have been lots of dedicated studies on the PCO (Phase Chrome Off-axis) mask technology and several design approaches have been proposed including grating background, chrome patches (or chrome shield) for applying PCO on line/space and contact pattern. In this paper, we studied the feasibility of grating design for line and contact pattern. The design of the grating pattern was provided from the EM simulation software (TEMPEST) and the aerial image simulation software. AIMS measurements with high NA annular illumination were done. Resist images were taken on designed pattern in different focus. Simulations, AIMS are compared to verify the consistency of the process with wafer printed performance.
Fischer, Christin; Kallinich, Constanze; Klockmann, Sven; Schrader, Jil; Fischer, Markus
2016-12-07
The present work demonstrates the first automated enrichment approach for antibiotics in milk using specific DNA aptamers. First, aptamers toward the antibiotic sulfanilamide were selected and characterized regarding their dissociation constants and specificity toward relevant antibiotics via fluorescence assay and LC-MS/MS detection. The performed enrichment was automated using the KingFisherDuo and compared to a manual approach. Verifying the functionality, trapping was realized in different milk matrices: (i) 0.3% fat milk, (ii) 1.5% fat milk, (iii) 3.5% fat milk, and (iv) 0.3% fat cocoa milk drink. Enrichment factors up to 8-fold could be achieved. Furthermore, it could be shown that novel implementation of a magnetic separator increases the reproducibility and reduces the hands-on time from approximately half a day to 30 min.
[Factor structure of symptoms in the Krakow Depression Inventory KID IO "B1" among 15-year-olds].
Bomba, Jacek; Modrzejewska, Renata; Beauvale, Andrzej
2011-01-01
The aim of the article is to partially verify the theoretical concept of depressive symptoms in adolescents, based on KID IO "B1", as well as to check the accuracy of the questionnaire. The KID results from an untreated sample population of 15-year-olds were statistically analysed. Of the 1118 KID IO "B1" questionnaires submitted, 594 (246 boys and 348 girls) underwent factor analysis, of which 297, i.e. half, gained a result higher than the diagnostic threshold for depression. In search of the presence of general factors, as well as to verify the principles used to categorise depressive symptoms according to clinical criteria, analysis of the factors using methods consisting of oblimin, quatrimax and varimax rotations was carried out separately and combined for both genders. The following new factors were distinguished for boys: I--lowered mood, and anxiety, II--self-destruction, III--apathy, cognitive disturbances, IV--somatic symptoms, V--somatisation, apathy, self-destruction, VI--boredom and avoidance of social contact, and for girls: I--lowered mood, lack of consideration for future repercussions, II--lowered drive, learning difficulties, cognitive and motivational disturbances, III--anxiety, IV--dysphoria with self-destruction, V--self-destruction, VI--eating pattern disturbances. Depression, as derived from factor analysis of the KID IO "B1" questionnaire positions, is heterogeneous. Theoretical division of symptom groups, relating to the specific scale in the questionnaire, was confirmed to a very small degree through the analysis of the factors. The list of factors in genders differs. The groups of symptoms appearing in both genders gained from analysis are different in boys and girls with one exception, which may partially result from the different factor overviews of depressive symptoms in both genders.
NASA Technical Reports Server (NTRS)
Ferrell, S., Jr.; Lahr, N.
1970-01-01
Simulator verifies proper operation of a battery cell voltage-monitoring device. It also contains variable ac voltage to ascertain that a battery scanner will perform its function at all possible ac voltages.
NASA Technical Reports Server (NTRS)
1974-01-01
Performance testing carried out in the development of the prototype zero-g fluid infusion system is described and summarized. Engineering tests were performed in the course of development, both on the original breadboard device and on the prototype system. This testing was aimed at establishing baseline system performance parameters and facilitating improvements. Acceptance testing was then performed on the prototype system to verify functional performance. Acceptance testing included a demonstration of the fluid infusion system on a laboratory animal.
15 CFR 995.27 - Format validation software testing.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 15 Commerce and Foreign Trade 3 2013-01-01 2013-01-01 false Format validation software testing... of NOAA ENC Products § 995.27 Format validation software testing. Tests shall be performed verifying, as far as reasonable and practicable, that CEVAD's data testing software performs the checks, as...
15 CFR 995.27 - Format validation software testing.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 15 Commerce and Foreign Trade 3 2014-01-01 2014-01-01 false Format validation software testing... of NOAA ENC Products § 995.27 Format validation software testing. Tests shall be performed verifying, as far as reasonable and practicable, that CEVAD's data testing software performs the checks, as...
15 CFR 995.27 - Format validation software testing.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 15 Commerce and Foreign Trade 3 2012-01-01 2012-01-01 false Format validation software testing... of NOAA ENC Products § 995.27 Format validation software testing. Tests shall be performed verifying, as far as reasonable and practicable, that CEVAD's data testing software performs the checks, as...
15 CFR 995.27 - Format validation software testing.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 15 Commerce and Foreign Trade 3 2011-01-01 2011-01-01 false Format validation software testing... of NOAA ENC Products § 995.27 Format validation software testing. Tests shall be performed verifying, as far as reasonable and practicable, that CEVAD's data testing software performs the checks, as...
48 CFR 245.7201 - Performing inventory verification and determination of allocability.
Code of Federal Regulations, 2010 CFR
2010-10-01
.... Use the following guidance for verifying inventory schedules— (a) Allocability. (1) Review contract... Government use. (2) Review the contractor's— (i) Recent purchases of similar material; (ii) Plans for current.... While a complete physical count of each item is not required, perform sufficient checks to ensure...
A performance verification demonstration of technologies capable of detecting dioxin and dioxin-like compounds in soil and sediment samples was conducted in April 2004 under the U.S. Environmental Protection Agency's Superfund Innovative Technology Evaluation (SITE) Monitoring an...
VERIFICATION OF THE HYDROLOGIC EVALUATION OF LANDFILL PERFORMANCE (HELP) MODEL USING FIELD DATA
The report describes a study conducted to verify the Hydrologic Evaluation of Landfill Performance (HELP) computer model using existing field data from a total of 20 landfill cells at 7 sites in the United States. Simulations using the HELP model were run to compare the predicted...
6 CFR 25.6 - Procedures for designation of qualified anti-terrorism technologies.
Code of Federal Regulations, 2010 CFR
2010-01-01
... available or can be feasibly conducted or obtained, including test results produced by an independent laboratory or other entity engaged to test or verify the safety, utility, performance, in order to assess the...; (ii) Classified and otherwise confidential studies; (iii) Studies, tests, or other performance records...
6 CFR 25.6 - Procedures for designation of qualified anti-terrorism technologies.
Code of Federal Regulations, 2014 CFR
2014-01-01
... available or can be feasibly conducted or obtained, including test results produced by an independent laboratory or other entity engaged to test or verify the safety, utility, performance, in order to assess the...; (ii) Classified and otherwise confidential studies; (iii) Studies, tests, or other performance records...
Near-ground tornado wind fields
DOE Office of Scientific and Technical Information (OSTI.GOV)
McDonald, J.R.
1984-07-01
A study of near-ground tornado wind fields has been conducted by inspecting damage and debris patterns found in tornado damage paths. Because there were no significant tornado events (F4 or greater) during the contract performance period, data from the literature and the files of the Institute for Disaster Research were used to perform the analyses. The results indicate: (1) maximum tornado wind speed ever experienced or expected is in the range of 250 to 300 mph; (2) appearance of damage, taken by itself, is a misleading parameter of tornado intensity. Type of construction, age of construction, materials and other constructionmore » features significantly affect structural performance of a building subjected to wind loads and should be taken into account in assigning Fujita-Scale ratings; (3) damage to forests gives a good indication of tornado wind field flow patterns, but do not give verifiable values of wind speed; (4) factors such as translational speed, wind direction and path width affect appearance of damage or a tornado; and (5) even the most awesome appearing missiles do not require incredible wind speeds to explain them. Some progress in computer simulation of tornado missiles have been made. 31 references, 8 figures, 2 tables.« less
Gelfi, Marcello; Solazzi, Luigi; Poli, Sandro
2017-03-06
This study is a detailed failure analysis of galvanized high carbon steel wires, which developed coating cracks during the torsion test performed as a quality control at the end of the manufacturing process. Careful visual inspections showed that the cracks are already present in the coating before the torsion test. In order to explain the origin of these cracks, systematic metallographic investigations were performed by means of optical and scanning electron microscope on both the wires and the rods that have been cold drawn to produce the wire. The chemical composition of the galvanized coatings was evaluated by means of energy dispersive spectroscopy. Micro bidimensional X-ray diffraction experiments were also performed to measure the residual stresses in the galvanized coating. The results showed that the failure is related to two main factors: the relatively high content of silicon in the steel and the unsuitable cooling rate of the rods at the exit from the galvanizing bath. The mechanism proposed to explain the origin of the defects was supported by Finite Elements Methods simulations and verified with in-plant tests. The proper countermeasures were then applied and the problem successfully solved.
Magnetic induction of hyperthermia by a modified self-learning fuzzy temperature controller
NASA Astrophysics Data System (ADS)
Wang, Wei-Cheng; Tai, Cheng-Chi
2017-07-01
The aim of this study involved developing a temperature controller for magnetic induction hyperthermia (MIH). A closed-loop controller was applied to track a reference model to guarantee a desired temperature response. The MIH system generated an alternating magnetic field to heat a high magnetic permeability material. This wireless induction heating had few side effects when it was extensively applied to cancer treatment. The effects of hyperthermia strongly depend on the precise control of temperature. However, during the treatment process, the control performance is degraded due to severe perturbations and parameter variations. In this study, a modified self-learning fuzzy logic controller (SLFLC) with a gain tuning mechanism was implemented to obtain high control performance in a wide range of treatment situations. This implementation was performed by appropriately altering the output scaling factor of a fuzzy inverse model to adjust the control rules. In this study, the proposed SLFLC was compared to the classical self-tuning fuzzy logic controller and fuzzy model reference learning control. Additionally, the proposed SLFLC was verified by conducting in vitro experiments with porcine liver. The experimental results indicated that the proposed controller showed greater robustness and excellent adaptability with respect to the temperature control of the MIH system.
Methodological evaluation and comparison of five urinary albumin measurements.
Liu, Rui; Li, Gang; Cui, Xiao-Fan; Zhang, Dong-Ling; Yang, Qing-Hong; Mu, Xiao-Yan; Pan, Wen-Jie
2011-01-01
Microalbuminuria is an indicator of kidney damage and a risk factor for the progression kidney disease, cardiovascular disease, and so on. Therefore, accurate and precise measurement of urinary albumin is critical. However, there are no reference measurement procedures and reference materials for urinary albumin. Nephelometry, turbidimetry, colloidal gold method, radioimmunoassay, and chemiluminescence immunoassay were performed for methodological evaluation, based on imprecision test, recovery rate, linearity, haemoglobin interference rate, and verified reference interval. Then we tested 40 urine samples from diabetic patients by each method, and compared the result between assays. The results indicate that nephelometry is the method with best analytical performance among the five methods, with an average intraassay coefficient of variation (CV) of 2.6%, an average interassay CV of 1.7%, a mean recovery of 99.6%, a linearity of R=1.00 from 2 to 250 mg/l, and an interference rate of <10% at haemoglobin concentrations of <1.82 g/l. The correlation (r) between assays was from 0.701 to 0.982, and the Bland-Altman plots indicated each assay provided significantly different results from each other. Nephelometry is the clinical urinary albumin method with best analytical performance in our study. © 2011 Wiley-Liss, Inc.
Gelfi, Marcello; Solazzi, Luigi; Poli, Sandro
2017-01-01
This study is a detailed failure analysis of galvanized high carbon steel wires, which developed coating cracks during the torsion test performed as a quality control at the end of the manufacturing process. Careful visual inspections showed that the cracks are already present in the coating before the torsion test. In order to explain the origin of these cracks, systematic metallographic investigations were performed by means of optical and scanning electron microscope on both the wires and the rods that have been cold drawn to produce the wire. The chemical composition of the galvanized coatings was evaluated by means of energy dispersive spectroscopy. Micro bidimensional X-ray diffraction experiments were also performed to measure the residual stresses in the galvanized coating. The results showed that the failure is related to two main factors: the relatively high content of silicon in the steel and the unsuitable cooling rate of the rods at the exit from the galvanizing bath. The mechanism proposed to explain the origin of the defects was supported by Finite Elements Methods simulations and verified with in-plant tests. The proper countermeasures were then applied and the problem successfully solved. PMID:28772623
Landsat 8 operational land imager on-orbit geometric calibration and performance
Storey, James C.; Choate, Michael J.; Lee, Kenton
2014-01-01
The Landsat 8 spacecraft was launched on 11 February 2013 carrying the Operational Land Imager (OLI) payload for moderate resolution imaging in the visible, near infrared (NIR), and short-wave infrared (SWIR) spectral bands. During the 90-day commissioning period following launch, several on-orbit geometric calibration activities were performed to refine the prelaunch calibration parameters. The results of these calibration activities were subsequently used to measure geometric performance characteristics in order to verify the OLI geometric requirements. Three types of geometric calibrations were performed including: (1) updating the OLI-to-spacecraft alignment knowledge; (2) refining the alignment of the sub-images from the multiple OLI sensor chips; and (3) refining the alignment of the OLI spectral bands. The aspects of geometric performance that were measured and verified included: (1) geolocation accuracy with terrain correction, but without ground control (L1Gt); (2) Level 1 product accuracy with terrain correction and ground control (L1T); (3) band-to-band registration accuracy; and (4) multi-temporal image-to-image registration accuracy. Using the results of the on-orbit calibration update, all aspects of geometric performance were shown to meet or exceed system requirements.
Top 10 revenue cycle mistakes.
Stuller, Elizabeth
2005-01-01
Hospitals looking to gain and maintain strong revenue cycle performance should avoid common mistakes, such as not verifying insurance coverage in advance and placing sole responsibility for correct documentation on physicians.
Finnish spectrolite as high-dose gamma detector
NASA Astrophysics Data System (ADS)
Antonio, Patrícia L.; Caldas, Linda V. E.
2015-11-01
A natural material called spectrolite, from Finland, was studied in this work. The purpose was to test it in gamma radiation beams to verify its performance as a high-dose detector. From this material, pellets were manufactured with two different concentrations of Teflon and spectrolite, and their responses were verified using two luminescent techniques: thermoluminescence (TL) and optically stimulated luminescence (OSL). The TL and OSL signals were evaluated by means of characterization tests of the material response, after exposure to a nominal absorbed dose interval of 5 Gy to 10 kGy. The results obtained, for both concentrations, showed a good performance of this material in beams of high-dose gamma radiation. Both techniques were utilized in order to investigate the properties of the spectrolite+Teflon samples for different applications.
Incidence, type of atrial fibrillation and risk factors for stroke: a population-based cohort study
Johansson, Cecilia; Dahlqvist, Erik; Andersson, Jonas; Jansson, Jan-Håkan; Johansson, Lars
2017-01-01
Purpose The aims of this study were to estimate the incidence of atrial fibrillation and atrial flutter (AF), to assess the presence of provoking factors and risk factors for stroke and systemic embolism, and to determine the type of AF in patients with first-diagnosed AF. Patients and methods This cohort study was performed in northern Sweden between January 1, 2011 and December 31, 2012. Diagnosis registries were searched for the International Classification of Diseases-10 code for AF (I48) to identify cases of incident AF. All AF diagnoses were electrocardiogram-verified. Data pertaining to provoking factors, type of AF and presence of risk factors for stroke and systemic embolism according to the CHA2DS2-VASc score were obtained from medical records. Results The incidence of AF in the entire population was 4.0 per 1,000 person-years. The incidence was 27.5 per 1,000 person-years in patients aged ≥80 years. A total of 21% of all patients had a provoking factor in association with the first-diagnosed episode of AF. The CHA2DS2-VASc score was 2 or higher in 81% of the patients. Permanent AF was the most common type of AF (29%). Conclusion There was a considerable increase in the incidence of AF with age, and a provoking factor was found in one-fifth. The most common type of AF was permanent AF. Four in five patients had a CHA2DS2-VASc score of 2 or more. PMID:28182159
Proving Correctness for Pointer Programs in a Verifying Compiler
NASA Technical Reports Server (NTRS)
Kulczycki, Gregory; Singh, Amrinder
2008-01-01
This research describes a component-based approach to proving the correctness of programs involving pointer behavior. The approach supports modular reasoning and is designed to be used within the larger context of a verifying compiler. The approach consists of two parts. When a system component requires the direct manipulation of pointer operations in its implementation, we implement it using a built-in component specifically designed to capture the functional and performance behavior of pointers. When a system component requires pointer behavior via a linked data structure, we ensure that the complexities of the pointer operations are encapsulated within the data structure and are hidden to the client component. In this way, programs that rely on pointers can be verified modularly, without requiring special rules for pointers. The ultimate objective of a verifying compiler is to prove-with as little human intervention as possible-that proposed program code is correct with respect to a full behavioral specification. Full verification for software is especially important for an agency like NASA that is routinely involved in the development of mission critical systems.
Practical system for generating digital mixed reality video holograms.
Song, Joongseok; Kim, Changseob; Park, Hanhoon; Park, Jong-Il
2016-07-10
We propose a practical system that can effectively mix the depth data of real and virtual objects by using a Z buffer and can quickly generate digital mixed reality video holograms by using multiple graphic processing units (GPUs). In an experiment, we verify that real objects and virtual objects can be merged naturally in free viewing angles, and the occlusion problem is well handled. Furthermore, we demonstrate that the proposed system can generate mixed reality video holograms at 7.6 frames per second. Finally, the system performance is objectively verified by users' subjective evaluations.
Thaden, Joshua T; Mogno, Ilaria; Wierzbowski, Jamey; Cottarel, Guillaume; Kasif, Simon; Collins, James J; Gardner, Timothy S
2007-01-01
Machine learning approaches offer the potential to systematically identify transcriptional regulatory interactions from a compendium of microarray expression profiles. However, experimental validation of the performance of these methods at the genome scale has remained elusive. Here we assess the global performance of four existing classes of inference algorithms using 445 Escherichia coli Affymetrix arrays and 3,216 known E. coli regulatory interactions from RegulonDB. We also developed and applied the context likelihood of relatedness (CLR) algorithm, a novel extension of the relevance networks class of algorithms. CLR demonstrates an average precision gain of 36% relative to the next-best performing algorithm. At a 60% true positive rate, CLR identifies 1,079 regulatory interactions, of which 338 were in the previously known network and 741 were novel predictions. We tested the predicted interactions for three transcription factors with chromatin immunoprecipitation, confirming 21 novel interactions and verifying our RegulonDB-based performance estimates. CLR also identified a regulatory link providing central metabolic control of iron transport, which we confirmed with real-time quantitative PCR. The compendium of expression data compiled in this study, coupled with RegulonDB, provides a valuable model system for further improvement of network inference algorithms using experimental data. PMID:17214507
Verifiable Measurement-Only Blind Quantum Computing with Stabilizer Testing.
Hayashi, Masahito; Morimae, Tomoyuki
2015-11-27
We introduce a simple protocol for verifiable measurement-only blind quantum computing. Alice, a client, can perform only single-qubit measurements, whereas Bob, a server, can generate and store entangled many-qubit states. Bob generates copies of a graph state, which is a universal resource state for measurement-based quantum computing, and sends Alice each qubit of them one by one. Alice adaptively measures each qubit according to her program. If Bob is honest, he generates the correct graph state, and, therefore, Alice can obtain the correct computation result. Regarding the security, whatever Bob does, Bob cannot get any information about Alice's computation because of the no-signaling principle. Furthermore, malicious Bob does not necessarily send the copies of the correct graph state, but Alice can check the correctness of Bob's state by directly verifying the stabilizers of some copies.
Verifiable Measurement-Only Blind Quantum Computing with Stabilizer Testing
NASA Astrophysics Data System (ADS)
Hayashi, Masahito; Morimae, Tomoyuki
2015-11-01
We introduce a simple protocol for verifiable measurement-only blind quantum computing. Alice, a client, can perform only single-qubit measurements, whereas Bob, a server, can generate and store entangled many-qubit states. Bob generates copies of a graph state, which is a universal resource state for measurement-based quantum computing, and sends Alice each qubit of them one by one. Alice adaptively measures each qubit according to her program. If Bob is honest, he generates the correct graph state, and, therefore, Alice can obtain the correct computation result. Regarding the security, whatever Bob does, Bob cannot get any information about Alice's computation because of the no-signaling principle. Furthermore, malicious Bob does not necessarily send the copies of the correct graph state, but Alice can check the correctness of Bob's state by directly verifying the stabilizers of some copies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carlson, J.J.; Bouchard, A.M.; Osbourn, G.C.
Future generation automated human biometric identification and verification will require multiple features/sensors together with internal and external information sources to achieve high performance, accuracy, and reliability in uncontrolled environments. The primary objective of the proposed research is to develop a theoretical and practical basis for identifying and verifying people using standoff biometric features that can be obtained with minimal inconvenience during the verification process. The basic problem involves selecting sensors and discovering features that provide sufficient information to reliably verify a person`s identity under the uncertainties caused by measurement errors and tactics of uncooperative subjects. A system was developed formore » discovering hand, face, ear, and voice features and fusing them to verify the identity of people. The system obtains its robustness and reliability by fusing many coarse and easily measured features into a near minimal probability of error decision algorithm.« less