Durable crystalline Si photovoltaic modules based on silicone-sheet encapsulants
NASA Astrophysics Data System (ADS)
Hara, Kohjiro; Ohwada, Hiroto; Furihata, Tomoyoshi; Masuda, Atsushi
2018-02-01
Crystalline Si photovoltaic (PV) modules were fabricated with sheets of poly(dimethylsiloxane) (silicone) as an encapsulant. The long-term durability of the silicone-encapsulated PV modules was experimentally investigated. The silicone-based modules enhanced the long-term durability against potential-induced degradation (PID) and a damp-heat (DH) condition at 85 °C with 85% relative humidity (RH). In addition, we designed and fabricated substrate-type Si PV modules based on the silicone encapsulant and an Al-alloy plate as the substratum, which demonstrated high impact resistance and high incombustible performance. The high chemical stability, high volume resistivity, rubber-like elasticity, and incombustibility of the silicone encapsulant resulted in the high durability of the modules. Our results indicate that silicone is an attractive encapsulation material, as it improves the long-term durability of crystalline Si PV modules.
Durability of yellow-poplar and sweetgum and service life of finishes after long-term exposure
R. Sam Williams; William C. Feist
2004-01-01
This report describes the results of long-term outdoor exposure on durability of hardwood plywood and the service life of various finishes. Smooth (abrasive-planed) and rough (saw-textured) yellow-poplar (Liriodendron tulipifera L.) and sweetgum (Liquidambar styraciflua L.) plywood panelswere exposed outdoors for 16 years near Madison, Wisconsin. The performance of...
The need for performance criteria in evaluating the durability of wood products
Stan Lebow; Bessie Woodward; Patricia Lebow; Carol Clausen
2010-01-01
Data generated from wood-product durability evaluations can be difficult to interpret. Standard methods used to evaluate the potential long-term durability of wood products often provide little guidance on interpretation of test results. Decisions on acceptable performance for standardization and code compliance are based on the judgment of reviewers or committees....
Thermodynamic model of natural, medieval and nuclear waste glass durability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jantzen, C.M.; Plodinec, M.J.
1983-01-01
A thermodynamic model of glass durability based on hydration of structural units has been applied to natural glass, medieval window glasses, and glasses containing nuclear waste. The relative durability predicted from the calculated thermodynamics correlates directly with the experimentally observed release of structural silicon in the leaching solution in short-term laboratory tests. By choosing natural glasses and ancient glasses whose long-term performance is known, and which bracket the durability of waste glasses, the long-term stability of nuclear waste glasses can be interpolated among these materials. The current Savannah River defense waste glass formulation is as durable as natural basalt frommore » the Hanford Reservation (10/sup 6/ years old). The thermodynamic hydration energy is shown to be related to the bond energetics of the glass. 69 references, 2 figures, 1 table.« less
Methods to determine long-term durability of Wisconsin aggregates.
DOT National Transportation Integrated Search
2013-02-01
Wisconsin uses approximately 10 to 11 million tons of aggregates annually in transportation infrastructure projects in the state. The quality of aggregates has a tremendous influence on the performance and durability of roadways and bridges. As sourc...
DOT National Transportation Integrated Search
2014-12-01
This project investigated the long-term performance of hot asphalt mixes containing crumb rubber : modifiers (CRM) added in dry or wet processes. A total of eight asphalt mixturesfour Porous : European Mixtures (PEMs) and four Stone Matrix Asphalt...
Investigation of testing methods to determine long-term durability of Wisconsin aggregates.
DOT National Transportation Integrated Search
2013-01-01
Approximately 10 to 11 million tons of aggregates are utilized in transportation infrastructure projects in : Wisconsin annually. The quality of aggregates has a tremendous influence on the performance and durability : of roadways and bridges. In thi...
Improved Durability of SOEC Stacks for High Temperature Electrolysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
James E. O'Brien; Robert C. O'Brien; Xiaoyu Zhang
2013-01-01
High temperature steam electrolysis is a promising technology for efficient and sustainable large-scale hydrogen production. Solid oxide electrolysis cells (SOECs) are able to utilize high temperature heat and electric power from advanced high-temperature nuclear reactors or renewable sources to generate carbon-free hydrogen at large scale. However, long term durability of SOECs needs to be improved significantly before commercialization of this technology can be realized. A degradation rate of 1%/khr or lower is proposed as a threshold value for commercialization of this technology. Solid oxide electrolysis stack tests have been conducted at Idaho National Laboratory to demonstrate recent improvements in long-termmore » durability of SOECs. Electrolyte-supported and electrode-supported SOEC stacks were provided by Ceramatec Inc. and Materials and Systems Research Inc. (MSRI), respectively, for these tests. Long-term durability tests were generally operated for a duration of 1000 hours or more. Stack tests based on technologies developed at Ceramatec and MSRI have shown significant improvement in durability in the electrolysis mode. Long-term degradation rates of 3.2%/khr and 4.6%/khr were observed for MSRI and Ceramatec stacks, espectively. One recent Ceramatec stack even showed negative degradation (performance improvement) over 1900 hours of operation. Optimization of electrode materials, interconnect coatings, and electrolyte-electrode interface microstructures contribute to better durability of SOEC stacks.« less
Concrete performance using low-degradation aggregates.
DOT National Transportation Integrated Search
2012-06-01
The durability of Portland cement concrete (PCC) has long been identified as a concern by transportation communities around the United States. In this study, the long-term performance of two batches of concrete incorporating either low-degradation (L...
Evaluation of the Long-Term Durability of Joints Cut Using Early Entry Saws on Rigid Pavements
DOT National Transportation Integrated Search
2011-01-01
Early-entry sawing is an attractive operation to expedite the construction of jointed concrete pavements; however, : there are some concerns that the early-entry sawing may compromise the pavements long-term performance. The Illinois : Department ...
US-23 aggregate test road long-term performance evaluation : final report.
DOT National Transportation Integrated Search
2017-03-24
The US-23 Aggregate Test Road was constructed in 1992 with the main purpose to determine the influence of coarse : aggregate of varying frost susceptibility on long-term concrete durability. The pavement structure for the entire Test Road consists : ...
Transarterial onyx embolization of cranial dural arteriovenous fistulas: long-term follow-up.
Chandra, R V; Leslie-Mazwi, T M; Mehta, B P; Yoo, A J; Rabinov, J D; Pryor, J C; Hirsch, J A; Nogueira, R G
2014-09-01
Endovascular therapy with liquid embolic agents is a common treatment strategy for cranial dural arteriovenous fistulas. This study evaluated the long-term effectiveness of transarterial Onyx as the single embolic agent for curative embolization of noncavernous cranial dural arteriovenous fistulas. We performed a retrospective review of 40 consecutive patients with 41 cranial dural arteriovenous fistulas treated between March 2006 and June 2012 by using transarterial Onyx embolization with intent to cure. The mean age was 57 years; one-third presented with intracranial hemorrhage. Most (85%) had cortical venous drainage. Once angiographic cure was achieved, long-term treatment effectiveness was assessed with DSA and clinical follow-up. Forty-nine embolization sessions were performed; 85% of cranial dural arteriovenous fistulas were treated in a single session. The immediate angiographic cure rate was 95%. The permanent neurologic complication rate was 2% (mild facial palsy). Thirty-five of the 38 patients with initial cure underwent short-term follow-up DSA (median, 4 months). The short-term recurrence rate was only 6% (2/35). All patients with occlusion at short-term DSA undergoing long-term DSA (median, 28 months) had durable occlusion. No patient with long-term clinical follow-up (total, 117 patient-years; median, 45 months) experienced hemorrhage. Transarterial embolization with Onyx as the single embolic agent results in durable long-term cure of noncavernous cranial dural arteriovenous fistulas. Recurrence rates are low on short-term follow-up, and all patients with angiographic occlusion on short-term DSA follow-up have experienced a durable long-term cure. Thus, angiographic cure should be defined at short-term follow-up angiography instead of at the end of the final embolization session. Finally, long-term DSA follow-up may not be necessary if occlusion is demonstrated on short-term angiographic follow-up. © 2014 by American Journal of Neuroradiology.
Durability and degradation of HT9 based alloy waste forms with variable Ni and Cr content
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olson, L.
2016-12-31
Short-term electrochemical and long-term hybrid electrochemical corrosion tests were performed on alloy waste forms in reference aqueous solutions that bound postulated repository conditions. The alloy waste forms investigated represent candidate formulations that can be produced with advanced electrochemical treatment of used nuclear fuel. The studies helped to better understand the alloy waste form durability with differing concentrations of nickel and chromium, species that can be added to alloy waste forms to potentially increase their durability and decrease radionuclide release into the environment.
RECENT ADVANCES IN HIGH TEMPERATURE ELECTROLYSIS AT IDAHO NATIONAL LABORATORY: STACK TESTS
DOE Office of Scientific and Technical Information (OSTI.GOV)
X, Zhang; J. E. O'Brien; R. C. O'Brien
2012-07-01
High temperature steam electrolysis is a promising technology for efficient sustainable large-scale hydrogen production. Solid oxide electrolysis cells (SOECs) are able to utilize high temperature heat and electric power from advanced high-temperature nuclear reactors or renewable sources to generate carbon-free hydrogen at large scale. However, long term durability of SOECs needs to be improved significantly before commercialization of this technology. A degradation rate of 1%/khr or lower is proposed as a threshold value for commercialization of this technology. Solid oxide electrolysis stack tests have been conducted at Idaho National Laboratory to demonstrate recent improvements in long-term durability of SOECs. Electrolytesupportedmore » and electrode-supported SOEC stacks were provided by Ceramatec Inc., Materials and Systems Research Inc. (MSRI), and Saint Gobain Advanced Materials (St. Gobain), respectively for these tests. Long-term durability tests were generally operated for a duration of 1000 hours or more. Stack tests based on technology developed at Ceramatec and MSRI have shown significant improvement in durability in the electrolysis mode. Long-term degradation rates of 3.2%/khr and 4.6%/khr were observed for MSRI and Ceramatec stacks, respectively. One recent Ceramatec stack even showed negative degradation (performance improvement) over 1900 hours of operation. A three-cell short stack provided by St. Gobain, however, showed rapid degradation in the electrolysis mode. Improvements on electrode materials, interconnect coatings, and electrolyteelectrode interface microstructures contribute to better durability of SOEC stacks.« less
Stirling engine - Approach for long-term durability assessment
NASA Technical Reports Server (NTRS)
Tong, Michael T.; Bartolotta, Paul A.; Halford, Gary R.; Freed, Alan D.
1992-01-01
The approach employed by NASA Lewis for the long-term durability assessment of the Stirling engine hot-section components is summarized. The approach consists of: preliminary structural assessment; development of a viscoplastic constitutive model to accurately determine material behavior under high-temperature thermomechanical loads; an experimental program to characterize material constants for the viscoplastic constitutive model; finite-element thermal analysis and structural analysis using a viscoplastic constitutive model to obtain stress/strain/temperature at the critical location of the hot-section components for life assessment; and development of a life prediction model applicable for long-term durability assessment at high temperatures. The approach should aid in the provision of long-term structural durability and reliability of Stirling engines.
Development and evaluation of endurance test system for ventricular assist devices.
Sumikura, Hirohito; Homma, Akihiko; Ohnuma, Kentaro; Taenaka, Yoshiyuki; Takewa, Yoshiaki; Mukaibayashi, Hiroshi; Katano, Kazuo; Tatsumi, Eisuke
2013-06-01
We developed a novel endurance test system that can arbitrarily set various circulatory conditions and has durability and stability for long-term continuous evaluation of ventricular assist devices (VADs), and we evaluated its fundamental performance and prolonged durability and stability. The circulation circuit of the present endurance test system consisted of a pulsatile pump with a small closed chamber (SCC), a closed chamber, a reservoir and an electromagnetic proportional valve. Two duckbill valves were mounted in the inlet and outlet of the pulsatile pump. The features of the circulation circuit are as follows: (1) the components of the circulation circuit consist of optimized industrial devices, giving durability; (2) the pulsatile pump can change the heart rate and stroke length (SL), as well as its compliance using the SCC. Therefore, the endurance test system can quantitatively reproduce various circulatory conditions. The range of reproducible circulatory conditions in the endurance test circuit was examined in terms of fundamental performance. Additionally, continuous operation for 6 months was performed in order to evaluate the durability and stability. The circulation circuit was able to set up a wide range of pressure and total flow conditions using the SCC and adjusting the pulsatile pump SL. The long-term continuous operation test demonstrated that stable, continuous operation for 6 months was possible without leakage or industrial device failure. The newly developed endurance test system demonstrated a wide range of reproducible circulatory conditions, durability and stability, and is a promising approach for evaluating the basic characteristics of VADs.
NASA Technical Reports Server (NTRS)
Halford, Gary R.; Shah, Ashwin; Arya, Vinod K.; Krause, David L.; Bartolotta, Paul A.
2002-01-01
Deep-space missions require onboard electric power systems with reliable design lifetimes of up to 10 yr and beyond. A high-efficiency Stirling radioisotope power system is a likely candidate for future deep-space missions and Mars rover applications. To ensure ample durability, the structurally critical heater head of the Stirling power convertor has undergone extensive computational analyses of operating temperatures (up to 650 C), stresses, and creep resistance of the thin-walled Inconel 718 bill of material. Durability predictions are presented in terms of the probability of survival. A benchmark structural testing program has commenced to support the analyses. This report presents the current status of durability assessments.
Highly durable, coking and sulfur tolerant, fuel-flexible protonic ceramic fuel cells.
Duan, Chuancheng; Kee, Robert J; Zhu, Huayang; Karakaya, Canan; Chen, Yachao; Ricote, Sandrine; Jarry, Angelique; Crumlin, Ethan J; Hook, David; Braun, Robert; Sullivan, Neal P; O'Hayre, Ryan
2018-05-01
Protonic ceramic fuel cells, like their higher-temperature solid-oxide fuel cell counterparts, can directly use both hydrogen and hydrocarbon fuels to produce electricity at potentially more than 50 per cent efficiency 1,2 . Most previous direct-hydrocarbon fuel cell research has focused on solid-oxide fuel cells based on oxygen-ion-conducting electrolytes, but carbon deposition (coking) and sulfur poisoning typically occur when such fuel cells are directly operated on hydrocarbon- and/or sulfur-containing fuels, resulting in severe performance degradation over time 3-6 . Despite studies suggesting good performance and anti-coking resistance in hydrocarbon-fuelled protonic ceramic fuel cells 2,7,8 , there have been no systematic studies of long-term durability. Here we present results from long-term testing of protonic ceramic fuel cells using a total of 11 different fuels (hydrogen, methane, domestic natural gas (with and without hydrogen sulfide), propane, n-butane, i-butane, iso-octane, methanol, ethanol and ammonia) at temperatures between 500 and 600 degrees Celsius. Several cells have been tested for over 6,000 hours, and we demonstrate excellent performance and exceptional durability (less than 1.5 per cent degradation per 1,000 hours in most cases) across all fuels without any modifications in the cell composition or architecture. Large fluctuations in temperature are tolerated, and coking is not observed even after thousands of hours of continuous operation. Finally, sulfur, a notorious poison for both low-temperature and high-temperature fuel cells, does not seem to affect the performance of protonic ceramic fuel cells when supplied at levels consistent with commercial fuels. The fuel flexibility and long-term durability demonstrated by the protonic ceramic fuel cell devices highlight the promise of this technology and its potential for commercial application.
Rebecca E. Ibach; Craig M. Clemons; Rebecca L. Schumann
2007-01-01
Although laboratory evaluations of wood-plastic composites (WPCs) are helpful in predicting long-term durability, field studies are needed to verify overall long-term durability. Field exposure can encompass numerous degradations i.e., fungal, ultraviolet light, moisture, wind, temperature, freeze/thaw, wet/ dry cycling, termites, mold, etc. that traditionally are...
Perry, Kyle A; Kanji, Aliyah; Drosdeck, Joseph M; Linn, John G; Chan, Anthony; Muscarella, Peter; Melvin, W Scott
2014-11-01
Laparoscopic Heller myotomy (LHM) has become the standard treatment for achalasia in the USA. Robot-assisted Heller myotomy (RHM) has emerged as an alternative approach due to improved visualization and fine motor control, but long-term follow-up studies have not been reported. We sought to report the long-term outcomes of RHM and compare them to those of LHM. A retrospective cohort study was performed for patients who underwent laparoscopic or RHM between 1995 and 2006. Long-term follow-up was performed via mail or telephone questionnaire. The primary outcome measure was durable relief of dysphagia without need for further intervention. Secondary outcomes included gastroesophageal reflux symptoms, disease-specific quality of life, and patient satisfaction with their operation. Seventy-five patients underwent laparoscopic (n = 19) or robotic (n = 56) myotomy during the study period. Long-term follow-up was obtained in 53 (71 %) patients with a median interval of 9 years. RHM was associated with a decreased mucosal injury rate (0 vs. 16 %, p = 0.01) and median hospital stay (1 vs. 2 days, p < 0.01) compared to conventional laparoscopy. All patients reported initial dysphagia relief, and 80 % required no further intervention. This did not differ between groups. Sixty-two percent required medications to control reflux symptoms at long-term follow-up, including 56 % following robotic myotomy and 80 % after laparoscopic myotomy (p = 0.27). Overall, 95 % of patients were satisfied with their operation, and 91 % would choose surgery again given the benefit of hindsight. There is a dearth of long-term follow-up data to support the effectiveness of RHM. This study demonstrates durable dysphagia relief in the vast majority of patients with a high degree of patient satisfaction and a low rate of esophageal mucosal injury. While a significant proportion of patients report reflux symptoms, these symptoms are well controlled with medical acid suppression.
Simultaneous structural and environmental loading of an ultra-high performance concrete component
DOT National Transportation Integrated Search
2010-07-01
Ultra-high performance concrete (UHPC) is an advanced cementitious composite material which tends to exhibit superior properties such as increased durability, strength, and long-term stability. This experimental investigation focused on the flexural ...
Monitoring the performance of timber bridges over the long term
James P. Wacker; Marc R. Joyal; Joseph F. Murphy; Xiping Wang
2007-01-01
Timber bridges are often viewed by engineers as less durable than steel or concrete structures. However, they remain a durable and economical option along secondary roads in many rural areas of the country. With well over 75,000 bridges listed by the Federal Highway Administrationâs National Bridge Inventory as having timber superstructures as of 2002, they represent...
Ten-year performance of treated northeastern softwoods in aboveground and ground-contact exposures
Douglas M. Crawford; Rodney C. De Groot; Lee R. Gjovik
The commercial value of several softwood species of the northeastern United States could be increased if these woods could be treated to meet existing American Wood Preserversa Association (AWPA) Standards and used in durable structures. We evaluated the long-term durability of incised and unincised white pine, red pine, eastern spruce, balsam fir, and eastern hemlock...
Materials research for high-speed civil transport and generic hypersonics: Composites durability
NASA Technical Reports Server (NTRS)
Allen-Lilly, Heather; Cregger, Eric; Hoffman, Daniel; Mccool, Jim
1995-01-01
This report covers a portion of an ongoing investigation of the durability of composites for the High Speed Civil Transport (HSCT) program. Candidate HSCT composites need to possess the high-temperature capability required for supersonic flight. This program was designed to initiate the design, analysis, fabrication, and testing of equipment intended for use in validating the long-term durability of materials for the HSCT. This equipment includes thermally actuated compression and tension fixtures, hydraulic-actuated reversible load fixtures, and thermal chambers. This equipment can be used for the durability evaluation of both composite and adhesive materials. Thermally actuated fixtures are recommended for fatigue cycling when long-term thermomechanical fatigue (TMF) data are required on coupon-sized tension or compression specimens. Long term durability testing plans for polymer matrix composite specimens are included.
NASA Technical Reports Server (NTRS)
Zhu, Dongming
2015-01-01
Environmental barrier coatings (EBCs) and SiCSiC ceramic matrix composites (CMCs) systems will play a crucial role in future turbine engines for hot-section component applications because of their ability to significantly increase engine operating temperatures, reduce engine weight and cooling requirements. The development of prime-reliant environmental barrier coatings is a key to enable the applications of the envisioned 2700-3000F EBC - CMC systems to help achieve next generation engine performance and durability goals. This paper will primarily address the performance requirements and design considerations of environmental barrier coatings for turbine engine applications. The emphasis is placed on current NASA candidate environmental barrier coating systems for SiCSiC CMCs, their performance benefits and design limitations in long-term operation and combustion environments. The efforts have been also directed to developing prime-reliant, self-healing 2700F EBC bond coat; and high stability, lower thermal conductivity, and durable EBC top coats. Major technical barriers in developing environmental barrier coating systems, the coating integrations with next generation CMCs having the improved environmental stability, cyclic durability, erosion-impact resistance, and long-term system performance will be described. The research and development opportunities for turbine engine environmental barrier coating systems by utilizing improved compositions, state-of-the-art processing methods, and simulated environment testing and durability modeling will be discussed.
Durability and smart condition assessment of ultra-high performance concrete in cold climates.
DOT National Transportation Integrated Search
2016-12-31
The goals of this study were to develop ecological ultra-high performance concrete (UHPC) with local materials and supplementary cementitious materials and to evaluate the long-term performance of UHPC in cold climates using effective mechanical test...
Development of a Family of Ultra-High Performance Concrete Pi-Girders
DOT National Transportation Integrated Search
2014-01-01
Ultra-high performance concrete (UHPC) is an advanced cementitious composite material, which tends to exhibit superior properties such as exceptional durability, increased strength, and long-term stability. (See references 1-4.) The use of existing s...
Long-Term Durability of Pressure-Treated Wood in a Severe Test Site
Stan Lebow; Bessie Woodward; Grant Kirker; Patricia Lebow
2013-01-01
Improved estimates of the long-term durability of treated wood products are needed to guide choices about construction materials and allow estimates of design life. This report summarizes the long-term decay and insect resistance of treated wood post and lumber specimens placed in ground contact at a test site of the U.S. Department of Agriculture, Forest Service,...
Well-defined porous membranes for robust omniphobic surfaces via microfluidic emulsion templating
NASA Astrophysics Data System (ADS)
Zhu, Pingan; Kong, Tiantian; Tang, Xin; Wang, Liqiu
2017-06-01
Durability is a long-standing challenge in designing liquid-repellent surfaces. A high-performance omniphobic surface must robustly repel liquids, while maintaining mechanical/chemical stability. However, liquid repellency and mechanical durability are generally mutually exclusive properties for many omniphobic surfaces--improving one performance inevitably results in decreased performance in another. Here we report well-defined porous membranes for durable omniphobic surfaces inspired by the springtail cuticle. The omniphobicity is shown via an amphiphilic material micro-textured with re-entrant surface morphology; the mechanical durability arises from the interconnected microstructures. The innovative fabrication method--termed microfluidic emulsion templating--is facile, cost-effective, scalable and can precisely engineer the structural topographies. The robust omniphobic surface is expected to open up new avenues for diverse applications due to its mechanical and chemical robustness, transparency, reversible Cassie-Wenzel transition, transferability, flexibility and stretchability.
NDT evaluation of long-term bond durability of CFRP-structural systems applied to RC highway bridges
NASA Astrophysics Data System (ADS)
Crawford, Kenneth C.
2016-06-01
The long-term durability of CFRP structural systems applied to reinforced-concrete (RC) highway bridges is a function of the system bond behavior over time. The sustained structural load performance of strengthened bridges depends on the carbon fiber-reinforced polymer (CFRP) laminates remaining 100 % bonded to concrete bridge members. Periodic testing of the CFRP-concrete bond condition is necessary to sustain load performance. The objective of this paper is to present a non-destructive testing (NDT) method designed to evaluate the bond condition and long-term durability of CFRP laminate (plate) systems applied to RC highway bridges. Using the impact-echo principle, a mobile mechanical device using light impact hammers moving along the length of a bonded CFRP plate produces unique acoustic frequencies which are a function of existing CFRP plate-concrete bond conditions. The purpose of this method is to test and locate CFRP plates de-bonded from bridge structural members to identify associated deterioration in bridge load performance. Laboratory tests of this NDT device on a CFRP plate bonded to concrete with staged voids (de-laminations) produced different frequencies for bonded and de-bonded areas of the plate. The spectra (bands) of frequencies obtained in these tests show a correlation to the CFRP-concrete bond condition and identify bonded and de-bonded areas of the plate. The results of these tests indicate that this NDT impact machine, with design improvements, can potentially provide bridge engineers a means to rapidly evaluate long lengths of CFRP laminates applied to multiple highway bridges within a national transportation infrastructure.
NASA Technical Reports Server (NTRS)
Zhu, Dongming
2016-01-01
This presentation reviews NASA environmental barrier coating (EBC) system development programs and the coating materials evolutions for protecting the SiC/SiC Ceramic Matrix Composites in order to meet the next generation engine performance requirements. The presentation focuses on several generations of NASA EBC systems, EBC-CMC component system technologies for SiC/SiC ceramic matrix composite combustors and turbine airfoils, highlighting the temperature capability and durability improvements in simulated engine high heat flux, high pressure, high velocity, and with mechanical creep and fatigue loading conditions. The current EBC development emphasis is placed on advanced NASA 2700F candidate environmental barrier coating systems for SiC/SiC CMCs, their performance benefits and design limitations in long-term operation and combustion environments. Major technical barriers in developing environmental barrier coating systems, the coating integrations with next generation CMCs having the improved environmental stability, erosion-impact resistance, and long-term fatigue-environment system durability performance are described. The research and development opportunities for advanced turbine airfoil environmental barrier coating systems by utilizing improved compositions, state-of-the-art processing methods, and simulated environment testing and durability modeling are discussed.
Learnable Interfaces--Leveraging Navigation by Design
ERIC Educational Resources Information Center
Swanson, Kari Gunvaldson
2012-01-01
Complex productivity applications that integrate tasks in the workplace are becoming more common. Usability typically focuses on short-term, immediate measures of task performance. This study incorporates a long-term goal of more durable learning, focusing on implicit learning (spontaneous, unplanned, usually unconscious learning as a result of…
This handbook contains protocols that compare the immediate performance of subslab depressurization (SSD) mitigation system with performance months or years later. These protocols provide a methodology to test SSD radon mitigation systems in situ to determine long-term performanc...
Well-defined porous membranes for robust omniphobic surfaces via microfluidic emulsion templating
Zhu, Pingan; Kong, Tiantian; Tang, Xin; Wang, Liqiu
2017-01-01
Durability is a long-standing challenge in designing liquid-repellent surfaces. A high-performance omniphobic surface must robustly repel liquids, while maintaining mechanical/chemical stability. However, liquid repellency and mechanical durability are generally mutually exclusive properties for many omniphobic surfaces—improving one performance inevitably results in decreased performance in another. Here we report well-defined porous membranes for durable omniphobic surfaces inspired by the springtail cuticle. The omniphobicity is shown via an amphiphilic material micro-textured with re-entrant surface morphology; the mechanical durability arises from the interconnected microstructures. The innovative fabrication method—termed microfluidic emulsion templating—is facile, cost-effective, scalable and can precisely engineer the structural topographies. The robust omniphobic surface is expected to open up new avenues for diverse applications due to its mechanical and chemical robustness, transparency, reversible Cassie–Wenzel transition, transferability, flexibility and stretchability. PMID:28604698
Long-Term benefits of stabilizing soil subgrades.
DOT National Transportation Integrated Search
2002-06-01
The main intent of this study was an attempt to address questions concerning bearing strengths, longevity, durability, structural credit, economics, and performance of pavements resting on soil subgrades mixed with chemical admixtures. In-depth field...
Diffusion vs. concentration of chloride ions in concrete.
DOT National Transportation Integrated Search
2014-06-01
This investigation was performed to gain insight and assist in determining the long-term durability of : reinforced concrete structures where the external chloride concentrations are different than those typically : observed at the permanently immers...
NASA Technical Reports Server (NTRS)
Nicholson, Lee M.; Whitley, Karen S.; Gates, Thomas S.
2001-01-01
Durability and long-term performance are among the primary concerns for the use of advanced polymer matrix composites (PMCs) in modern aerospace structural applications. For a PMC subJected to long-term exposure at elevated temperatures. the viscoelastic nature of the polymer matrix will contribute to macroscopic changes in composite stiffness, strength and fatigue life. Over time. changes in the polymer due to physical aging will have profound effects on tile viscoelastic compliance of the material, hence affecting its long-term durability. Thus, the ability to predict material performance using intrinsic properties, such as crosslink density and molecular weight, would greatly enhance the efficiency of design and development of PMCs. The objective of this paper is to discuss and present the results of an experimental study that considers the effects of crosslink density, molecular weight and temperature on the viscoelastic behavior including physical aging of an advanced polymer. Five distinct variations in crosslink density were used to evaluate the differences in mechanical performance of an advanced polyimide. The physical aging behavior was isolated by conducting sequenced, short-term isothermal creep compliance tests in tension. These tests were performed over a range of sub-glass transition temperatures. The material constants, material master curves and physical aging-related parameters were evaluated as a function of temperature crosslink density and molecular weight using time-temperature and time-aging time superposition techniques.
Rogo-Gupta, Lisa; Baxter, Z Chad; Le, Ngoc-Bich; Raz, Shlomo; Rodríguez, Larissa V
2012-11-01
We report on the long-term outcomes of the distal urethral polypropylene sling for stress urinary incontinence in a patient cohort that was closely followed and whose outcomes were reported at 1 and 5 years after surgery. We performed a prospective study of all consecutive patients who underwent a distal urethral polypropylene sling procedure between November 1999 and April 2000. The 1 and 5-year outcomes for this particular patient cohort were previously reported. At the minimum 11-year followup, outcome was determined by patient self-assessment including validated questionnaires. A total of 69 patients were followed prospectively and followup was obtained for 30. Of those lost to followup 10 were deceased and 5 were cognitively impaired. Mean patient age at followup was 73 years (range 40 to 97). More than 11 years after surgery 48% of patients reported no stress urinary incontinence symptoms and 63% were never bothered by stress urinary incontinence. Patients reported a mean overall symptom improvement of 64% compared to 81% at 5 years. Overall 82% of patients met the criteria for treatment success by symptom scores and 80% met the criteria by bother scores. The distal urethral polypropylene sling procedure has excellent long-term durability in the treatment of stress urinary incontinence, in addition to low morbidity and low cost as previously described. Eleven years after the procedure the majority of patients report symptom improvement. Nevertheless, many older patients are unable to participate in followup. When choosing an anti-incontinence procedure, durability should be considered in light of patient age given that the theoretical advantages of long-term durability are limited by cognitive decline and mortality. Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jenner, Elliot; Barbier, Charlotte N; D'Urso, Brian R
Robust and easily produced Superhydrophobic surfaces are of great interest for mechanical applications, including drag reduction and MEMS. We produce novel superhydrophobic surfaces with several different coatings and tested the durability of each of these coatings with respect to long term immersion in water in order to determine the most long-lasting surface preparation. A pair of combinations of spin on polymers, surface features, and adhesion promoters was found that provide long term durability.
Laboratory and field evaluation of concrete paving curing effectiveness.
DOT National Transportation Integrated Search
2009-12-01
Ensuring that sufficient water is available in hydrating concrete is of great importance to produce durable : concrete and achieve both short- and long-term performance of concrete pavement. Excessive early-age : evaporation from the surface of concr...
NASA Technical Reports Server (NTRS)
Zhu, Dongming
2016-01-01
This presentation briefly reviews the SiC/SiC major environmental and environment-fatigue degradations encountered in simulated turbine combustion environments, and thus NASA environmental barrier coating system evolution for protecting the SiC/SiC Ceramic Matrix Composites for meeting the engine performance requirements. The presentation will review several generations of NASA EBC materials systems, EBC-CMC component system technologies for SiC/SiC ceramic matrix composite combustors and turbine airfoils, highlighting the temperature capability and durability improvements in simulated engine high heat flux, high pressure, high velocity, and with mechanical creep and fatigue loading conditions. This paper will also focus on the performance requirements and design considerations of environmental barrier coatings for next generation turbine engine applications. The current development emphasis is placed on advanced NASA candidate environmental barrier coating systems for SiC/SiC CMCs, their performance benefits and design limitations in long-term operation and combustion environments. The efforts have been also directed to developing prime-reliant, self-healing 2700F EBC bond coat; and high stability, lower thermal conductivity, and durable EBC top coats. Major technical barriers in developing environmental barrier coating systems, the coating integrations with next generation CMCs having the improved environmental stability, erosion-impact resistance, and long-term fatigue-environment system durability performance will be described. The research and development opportunities for turbine engine environmental barrier coating systems by utilizing improved compositions, state-of-the-art processing methods, and simulated environment testing and durability modeling will be briefly discussed.
Long-term durability of CCA and ACA : how is 0.4 doing?
Stan T. Lebow; Cherilyn A. Hatfield; Bessie Woodward
2010-01-01
For decades the phrase âpoint 4â was synonymous with wood treated for use in contact with the ground. In this paper we review how and why the 0.4 lb/ft3 (6.4 kg/m3) retention became such an accepted standard, and then evaluate how well this retention has performed in long term stake testing. Data from plots near Saucier,...
den Uil, Corstiaan A; Akin, Sakir; Jewbali, Lucia S; Dos Reis Miranda, Dinis; Brugts, Jasper J; Constantinescu, Alina A; Kappetein, Arie Pieter; Caliskan, Kadir
2017-07-01
Short-term mechanical circulatory support (MCS) is increasingly used as a bridge to decision in patients with refractory cardiogenic shock. Subsequently, these patients might be bridged to durable MCS either as a bridge to candidacy/transplantation, or as destination therapy. The aim of this study was to review support duration and clinical outcome of short-term MCS in cardiogenic shock, and to analyse application of this technology as a bridge to long-term cardiac support (left ventricular assist device, LVAD) from 2006 till June 2016. Using Cochrane Register of Trials, Embase and Medline, a systematic review was performed on patients with cardiogenic shock from acute myocardial infarction, end-stage cardiomyopathy, or acute myocarditis, receiving short-term MCS. Studies on periprocedural, post-cardiotomy and cardiopulmonary resuscitation support were excluded. Thirty-nine studies, mainly registries of heterogeneous patient populations (n = 4151 patients), were identified. Depending on the device used (intra-aortic balloon pump, TandemHeart, Impella 2.5, Impella 5.0, CentriMag and peripheral veno-arterial extracorporeal membrane oxygenation), mean support duration was (range) 1.6-25 days and the mean proportion of short-term MCS patients discharged was (range) 45-66%. The mean proportion of bridge to durable LVAD was (range) 3-30%. Bridge to durable LVAD was most frequently performed in patients with end-stage cardiomyopathy (22 [12-35]%). We conclude that temporary MCS can be used to bridge patients with cardiogenic shock towards durable LVAD. Clinicians are encouraged to share their results in a large multicentre registry in order to investigate optimal device selection and best duration of support. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Performance and Durability of Environmental Barrier Coatings on SiC/SiC Ceramic Matrix Composites
NASA Technical Reports Server (NTRS)
Zhu, Dongming; Harder, Bryan; Bhatt, Ramakrishna
2016-01-01
This presentation highlights advanced environmental barrier coating (EBC) and SiC-SiC Ceramic Matrix Composites (CMC) systems for next generation turbine engines. The emphasis will be placed on fundamental coating and CMC property evaluations; and the integrated system performance and degradation mechanisms in simulated laboratory turbine engine testing environments. Long term durability tests in laser rig simulated high heat flux the rmomechanical creep and fatigue loading conditions will also be presented. The results can help improve the future EBC-CMC system designs, validating the advanced EBC-CMC technologies for hot section turbine engine applications.
Laboratory evaluation of 100 percent fly ash cementitious systems : tech summary.
DOT National Transportation Integrated Search
2016-12-01
Long-lasting durable concrete is a must-have for departments of transportation (DOTs) in todays : construction and economic climate. Many entities are turning to alternative concrete mixtures to : ensure long-term durability such as ternary mixtur...
NASA Technical Reports Server (NTRS)
Johnson, W. Steven
1990-01-01
A workshop was held to help assess the state-of-the-art in evaluating the long term durability of polymeric matrix composites (PMCs) and to recommend future activities. Design and evaluation of PMCs at elevated temperatures were discussed. The workshop presentations, the findings of the workshop sessions are briefly summarized.
Laboratory evaluation of 100 percent fly ash cementitious systems : final report 573.
DOT National Transportation Integrated Search
2016-12-01
Long-lasting, durable concrete is a must have for Departments of Transportation (DOTs) in todays construction and economic climate. Many entities are : turning to alternative concrete mixtures to ensure long-term durability such as ternary mixt...
Long-term strength determination for cooled blades made of monocrystalline superalloys
NASA Astrophysics Data System (ADS)
Getsov, L. B.; Semenov, A. S.; Besschetnov, V. A.; Grishchenko, A. I.; Semenov, S. G.
2017-04-01
For the manufacture of blades for modern gas-turbine installations, monocrystalline alloys are used. Traditional methods for the calculation of stressed-deformed state and safety factors for these alloys developed and verified for polycrystalline materials need to be adjusted. This paper deals with methodological principles for an approach to the solving of the problem concerning a finite-element determination of the long-term static strength for cooled monocrystalline blades employed in gas-turbine installations based on the use of two different models (phenomenological and micromechanical) considering the inelastic deformation of monocrystalline superalloys. An analysis has been performed for the distribution of Schmid factors in the spherical triangle for primary and secondary octahedral and cubic slip systems. Calculations are performed using Larson-Miller's parametric dependences taking into account the crystallographic orientation of the material. A determination procedure for the anisotropy coefficients of long-term strength is described based on data for different orientations. A comparative analysis of the results of finite-element calculations made using phenomenological and micromechanical (crystallographic) creep models for the long-term static strength of cooled monocrystalline blades used in a gas-turbine engine has been performed. It is shown that the location of the most loaded sections of such a blade coincide with the results of calculations according to these models. It has been found that the micromechanical deformation model results in the obtaining of the most conservative estimate for the long-term strength of turbine blades made of monocrystalline alloys. It is shown that the calculations using models for materials with isotropic properties can produce considerable errors in determining the durability of the blades. The possibility is considered for using 1D-, 2D-, and 3D-models for turbine monocrystalline blades in the determination of their durability parameters.
Ahsan, Syed F; Huq, Farhan; Seidman, Michael; Taylor, Andrew
2017-12-01
The objective is to perform a systematic review and meta-analysis of the literature on the long-term results of hearing preservation after vestibular schwannoma resection. Ovid/Medline, PubMed, Embase, and the Cochrane library from January 1980 to January 2015. Inclusion criteria: age ≥18 years, minimum 10 patients in the treatment group, hearing preserving microsurgery, no previous radiation treatment, serviceable hearing at immediate postop follow-up, hearing outcomes reported using Gardner Robinson or the American Academy of Otolaryngology-Head and Neck Surgeons hearing grading scales, and average follow-up of 5 years. Preoperative, immediate postoperative, and last follow-up audiograms were required. Exclusion criteria included neurofibromatosis type 2 patients and surgery for salvage therapy or decompression. Quality evaluated using Methodological Index for Non-Randomized Studies. Meta-analysis was performed using R v3.2.2, Metafor package v 1.9-7. Cohen's D was used to determine effect size. Ten reports had at least 5-year follow-up and used standardized hearing grading scales. The systematic review found that if hearing was preserved at Class A or B at early postop visit, the chance of preserving hearing at 5 years was excellent. Those who maintained speech discrimination score ≥ 89% at the early postoperative follow-up had better long-term hearing preservation. The meta-analysis reveals that only preoperative and postoperative pure-tone average was associated with long-term hearing preservation. Long-term (>5 yr) hearing durability rates are generally very good. Most studies do not report patient and tumor characteristics, therefore precluding combining studies for meta-analysis. Only preoperative and postoperative postoperative pure-tone average was associated with long-term hearing durability.
Optimizing the durability of the coarse fraction of porous asphalt RAP for effective recycling
NASA Astrophysics Data System (ADS)
Holleran, Irina; Wilson, Douglas J.; Black, Philippa; Holleran, Glynn; Walubita, Lubinda F.
2017-09-01
Porous asphalt (PA) durability depends not only on the binder used to manufacture the mix, but also on the aggregates chosen, particularly the coarse fraction component. Aggregates for PA should be of the highest quality and highly durable to withstand the effects of weather and traffic. To recycle PA into a new PA mix, without compromising the long-term performance, the durability of the recovered aggregates from PA-derived reclaimed asphalt pavement (RAP) should be assessed alongside the aged binder properties. In this study, the Micro-Deval (MD) Abrasion test, combined with water absorption, was found to be a good predictor of asphalt mix performance for PA. Minerology of the aggregates is an important factor when setting limits for MD loss. New Zealand (NZ) aggregates are significantly younger in geological terms, and chemically and physically less stable compared to the aggregates used in many other countries. This is especially true for greywacke, the most used aggregate in NZ for road construction. If the MD limits reported in some literature are applied to NZ PA-derived RAP aggregates, poor performing material can be erroneously incorporated in asphalt mixes. Findings from this study contributes in understanding how PA-derived RAP can be recycled into new value PA mixes.
DOT National Transportation Integrated Search
2016-07-01
Glass fiber reinforced polymer (GFRP) composites are emerging as a feasible economical solution to eliminate the : corrosion problem of steel reinforcements in the concrete industry. Confirmation of GFRP long-term durability is crucial : to extend it...
Modeling the long-term durability of concrete barriers in the context of low-activity waste storage
NASA Astrophysics Data System (ADS)
Protière, Y.; Samson, E.; Henocq, P.
2013-07-01
The paper investigates the long-term durability of concrete barriers in contact with a cementitious wasteform designed to immobilize low-activity nuclear waste. The high-pH pore solution of the wasteform contains high concentration level of sulfate, nitrate, nitrite and alkalis. The multilayer concrete/wasteform system was modeled using a multiionic reactive transport model accounting for coupling between species, dissolution/ precipitation reactions, and feedback effect. One of the primary objectives was to investigate the risk associated with the presence of sulfate in the wasteform on the durability of concrete. Simulation results showed that formation of expansive phases, such as gypsum and ettringite, into the concrete barrier was not extensive. Based on those results, it was not possible to conclude that concrete would be severely damaged, even after 5,000 years. Lab work was performed to provide data to validate the modeling results. Paste samples were immersed in sulfate contact solutions and analyzed to measure the impact of the aggressive environment on the material. The results obtained so far tend to confirm the numerical simulations.
NASA Technical Reports Server (NTRS)
Lau, Kreisler S. Y.; Landis, Abraham L.; Chow, Andrea W.; Hamlin, Richard D.
1993-01-01
To achieve acceptable performance and long-term durability at elevated temperatures (350 to 600 F) for high-speed transport systems, further improvements of the high-performance matrix materials will be necessary to achieve very long-term (60,000-120,000 service hours) retention of mechanical properties and damage tolerance. This report emphasizes isoimide modification as a complementary technique to semi-interpenetrating polymer networks (SIPN's) to achieve greater processibility, better curing dynamics, and possibly enhanced thermo-mechanical properties in composites. A key result is the demonstration of enhanced processibility of isoimide-modified linear and thermo-setting polyimide systems.
Measure Guideline. Wood Window Repair, Rehabilitation, and Replacement
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, P.; Eng, P.
2012-12-01
This measure guideline provides information and guidance on rehabilitating, retrofitting, and replacing existing window assemblies in residential construction. The intent is to provide information regarding means and methods to improve the energy and comfort performance of existing wood window assemblies in a way that takes into consideration component durability, in-service operation, and long term performance of the strategies.
Measure Guideline: Window Repair, Rehabilitation, and Replacement
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, P.
2012-12-01
This measure guideline provides information and guidance on rehabilitating, retrofitting, and replacing existing window assemblies in residential construction. The intent is to provide information regarding means and methods to improve the energy and comfort performance of existing wood window assemblies in a way that takes into consideration component durability, in-service operation, and long term performance of the strategies.
Kitano, Tomoya; Iwasaki, Kiyotaka
The EVAHEART Left Ventricular Assist System (LVAS) was designed for the long-term support of a patient with severe heart failure. It has an original water lubrication system for seal and bearing and wear on these parts was considered one of its critical failure modes. A durability test focusing on wear was designed herein. We developed a mock loop, which generates a physiologic pulsatile flow and is sufficiently durable for a long-term test. The pulsatile load and the low fluid viscosity enable the creation of a severe condition for the mechanical seal. A total of 18 EVAHEART blood pumps completed 2 years of operation under the pulsatile condition without any failure. It indicated the EVAHEART blood pump had a greater than 90% reliability with a 88% confidence level. The test was continued with six blood pumps and achieved an average of 8.6 years, which was longer than the longest clinical use in Japan. The test result showed that no catastrophic, critical, marginal, or minor failures of the blood pump or their symptoms were observed. The seal performance was maintained after the test. Moreover, the surface roughness did not change, which showed any burn or abnormal wear occurred. The original water lubrication system equipped in EVAHEART LVAS prevent severe wear on the seal and the bearing, and it can be used in the bridge to transplant and destination therapy.
Long-term follow-up of aneurysms treated electively with woven stent-assisted coiling.
Cheung, Nicholas K; Chiu, Albert Hy; Cheung, Andrew K; Wenderoth, Jason D
2017-12-15
Preliminary short-term results for stent-assisted coil embolization (SACE) using woven/braided stents have been promising. However, evidence supporting mid- to long-term efficacy and durability is lacking. To report the long-term results for the durability of elective intracranial aneurysms treated with woven stents. Between May 2012 and May 2015, 98 consecutive patients with 103 aneurysms underwent elective woven SACE across three Australian neurovascular centres. All patients had immediate, 6- and 18-month clinical and radiological follow-up. Radiological assessment was performed with modified Raymond-Roy occlusion scores based on angiography results, while clinical assessment was based on the modified Rankin Scale. Six-month follow-up was available in 100 aneurysms, and an 18-month follow-up in 97 aneurysms. Total occlusion rates of 82% were achieved at inception, 82% at 6 months, and 90% at 18 months. Satisfactory occlusion with small neck remnants was present in 17% at inception, 16% at 6 months, and 9% at 18 months. Good neurological outcomes were achieved in 95% at 18 months. Intraprocedural thromboembolic events were recorded in 3% and delayed events in 1% (all in patients taking clopidogrel). Aneurysm recurrence occurred in one patient (1%). Technical complications occurred in 5%. The total complication rate was 10%. Woven SACE is safe, efficacious, and durable at long-term 18-month follow-up, with very low recurrence and re-treatment rates. Preliminary results appear better than those for traditional laser-cut stents. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Disbonding effects on elastic wave generation and reception by bonded piezoelectric sensor systems
NASA Astrophysics Data System (ADS)
Blackshire, James L.; Martin, Steven A.; Na, Jeong K.
2007-04-01
Durable integrated sensor systems are needed for long-term health monitoring evaluations of aerospace systems. For legacy aircraft the primary means of implementing a sensor system will be through surface mounting or bonding of the sensors to the structure. Previous work has shown that the performance of surface-bonded piezo sensors can degrade due to environmental effects such as vibrations, temperature fluctuations, and substrate flexure motions. This performance degradation included sensor cracking, disbonding, and general loss of efficiency over time. In this research effort, the bonding state of a piezo sensor system was systematically studied to understand and improve the long-term durability and survivability of the sensor system. Analytic and computational models were developed and used to understand elastic wave generation and reception performance for various states of sensor disbond. Experimental studies were also conducted using scanning laser vibrometry, pitch-catch ultrasound, and pulse-echo ultrasound methods to understand elastic wave propagation effects in thin plate materials. Significant performance loss was observed for increasing levels of sensor disbond as well as characteristic frequency signatures which may be useful in understanding sensor performance levels for future structural health monitoring systems.
Haskins, Ivy N; Strong, Andrew T; Baginsky, Mary; Sharma, Gautam; Karafa, Matthew; Ponsky, Jeffrey L; Rodriguez, John H; Kroh, Matthew D
2018-05-01
Enteral access through the jejunum is indicated when patients cannot tolerate oral intake or gastric feeding. While multiple approaches for feeding jejunal access exist, few studies have compared the efficacy of these techniques. The purpose of this study was to investigate the long-term durability, re-intervention rates, and nutritional outcomes following percutaneous endoscopic gastrostomy tubes with jejunal extension tubes (PEG-JET) versus laparoscopic jejunostomy tubes (j-tubes). Retrospective chart review was performed on all patients who underwent PEG-JET or laparoscopic jejunostomy tube placement from January 2005 through December 2015 at our institution. Thirty-day and long-term outcomes were compared between the two groups. A total of 105 patients underwent PEG-JET and 307 patients underwent laparoscopic j-tube placement during the defined study period. In terms of 30-day outcomes, patients who underwent PEG-JET placement were significantly more likely to experience a tube dislodgement event (p = 0.005) and undergo a re-intervention (p < 0.001). Patients who had a laparoscopic j-tube placed were significantly more likely to meet their enteral feeding goals (p = 0.002) and less likely to require nutritional supplementation with total parenteral nutrition (TPN) (p < 0.001). With regard to long-term outcomes, patients who underwent PEG-JET placement were significantly more likely to experience tube occlusion (p < 0.001) and require an endoscopic or surgical tube re-intervention (p < 0.001). Patients who underwent laparoscopic j-tube placement were significantly more likely to experience a tube site leak (p = 0.015) but were less likely to require nutritional supplementation with TPN (p = 0.001). Laparoscopic jejunostomy tubes provide more durable long-term enteral access compared to PEG-JET. Consideration should be given to laparoscopic jejunostomy tube placement in eligible patients who cannot tolerate oral intake or gastric enteral feeding.
NASA Astrophysics Data System (ADS)
Pohl, E.; Maximini, M.; Bauschulte, A.; vom Schloß, J.; Hermanns, R. T. E.
2015-02-01
HT-PEM fuel cells suffer from performance losses due to degradation effects. Therefore, the durability of HT-PEM is currently an important factor of research and development. In this paper a novel approach is presented for an integrated short term and long term simulation of HT-PEM accelerated lifetime testing. The physical phenomena of short term and long term effects are commonly modeled separately due to the different time scales. However, in accelerated lifetime testing, long term degradation effects have a crucial impact on the short term dynamics. Our approach addresses this problem by applying a novel method for dual time scale simulation. A transient system simulation is performed for an open voltage cycle test on a HT-PEM fuel cell for a physical time of 35 days. The analysis describes the system dynamics by numerical electrochemical impedance spectroscopy. Furthermore, a performance assessment is performed in order to demonstrate the efficiency of the approach. The presented approach reduces the simulation time by approximately 73% compared to conventional simulation approach without losing too much accuracy. The approach promises a comprehensive perspective considering short term dynamic behavior and long term degradation effects.
Durability evaluation of reversible solid oxide cells
NASA Astrophysics Data System (ADS)
Zhang, Xiaoyu; O'Brien, James E.; O'Brien, Robert C.; Housley, Gregory K.
2013-11-01
An experimental investigation on the performance and durability of single solid oxide cells (SOCs) is under way at the Idaho National Laboratory. Reversible operation of SOCs includes electricity generation in the fuel cell mode and hydrogen generation in the electrolysis mode. Degradation is a more significant issue when operating SOCs in the electrolysis mode. In order to understand and mitigate the degradation issues in high temperature electrolysis, single SOCs with different configurations from several manufacturers have been evaluated for initial performance and long-term durability. Cells were obtained from four industrial partners. Cells from Ceramatec Inc. and Materials and Systems Research Inc. (MSRI) showed improved durability in electrolysis mode compared to previous stack tests. Cells from Saint Gobain Advanced Materials Inc. (St. Gobain) and SOFCPower Inc. demonstrated stable performance in the fuel cell mode, but rapid degradation in the electrolysis mode, especially at high current density. Electrolyte-electrode delamination was found to have a significant impact on degradation in some cases. Enhanced bonding between electrolyte and electrode and modification of the electrode microstructure helped to mitigate degradation. Polarization scans and AC impedance measurements were performed during the tests to characterize cell performance and degradation.
DOT National Transportation Integrated Search
2016-07-01
Glass fiber reinforced polymer (GFRP) composites are emerging as a feasible economical solution to eliminate the corrosion problem of steel reinforcements in the concrete industry. Confirmation of GFRP long-term durability is crucial to extend its ap...
Arizzi, Anna; Viles, Heather; Martín-Sanchez, Inés; Cultrone, Giuseppe
2016-01-15
Hemp-based composites are eco-friendly building materials as they improve energy efficiency in buildings and entail low waste production and pollutant emissions during their manufacturing process. Nevertheless, the organic nature of hemp enhances the bio-receptivity of the material, with likely negative consequences for its long-term performance in the building. The main purpose of this study was to study the response at macro- and micro-scale of hemp-lime renders subjected to weathering simulations in an environmental cabinet (one year was condensed in twelve days), so as to predict their long-term durability in coastal and inland areas with Mediterranean, Tropical and Semi-arid climates, also in relation with the lime type used. The simulated climatic conditions caused almost unnoticeable mass, volume and colour changes in hemp-lime renders. No efflorescence or physical breakdown was detected in samples subjected to NaCl, because the salt mainly precipitates on the surface of samples and is washed away by the rain. Although there was no visible microbial colonisation, alkaliphilic fungi (mainly Penicillium and Aspergillus) and bacteria (mainly Bacillus and Micrococcus) were isolated in all samples. Microbial growth and diversification were higher under Tropical climate, due to heavier rainfall. The influence of the bacterial activity on the hardening of samples has also been discussed here and related with the formation and stabilisation of vaterite in hemp-lime mixes. This study has demonstrated that hemp-lime renders show good durability towards a wide range of environmental conditions and factors. However, it might be useful to take some specific preventive and maintenance measures to reduce the bio-receptivity of this material, thus ensuring a longer durability on site. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhang, Enren; Wang, Feng; Yu, Qingling; Scott, Keith; Wang, Xu; Diao, Guowang
2017-08-01
The performance of activated carbon catalyst in air-cathodes in microbial fuel cells was investigated over one year. A maximum power of 1722 mW m-2 was produced within the initial one-month microbial fuel cell operation. The air-cathodes produced a maximum power >1200 mW m-2 within six months, but gradually became a limiting factor for the power output in prolonged microbial fuel cell operation. The maximum power decreased by 55% when microbial fuel cells were operated over one year due to deterioration in activated carbon air-cathodes. While salt/biofilm removal from cathodes experiencing one-year operation increased a limiting performance enhancement in cathodes, a washing-drying-pressing procedure could restore the cathode performance to its original levels, although the performance restoration was temporary. Durable cathodes could be regenerated by re-pressing activated carbon catalyst, recovered from one year deteriorated air-cathodes, with new gas diffusion layer, resulting in ∼1800 mW m-2 of maximum power production. The present study indicated that activated carbon was an effective catalyst in microbial fuel cell cathodes, and could be recovered for reuse in long-term operated microbial fuel cells by simple methods.
Extremely Durable, Flexible Supercapacitors with Greatly Improved Performance at High Temperatures.
Kim, Sung-Kon; Kim, Hae Jin; Lee, Jong-Chan; Braun, Paul V; Park, Ho Seok
2015-08-25
The reliability and durability of energy storage devices are as important as their essential characteristics (e.g., energy and power density) for stable power output and long lifespan and thus much more crucial under harsh conditions. However, energy storage under extreme conditions is still a big challenge because of unavoidable performance decays and the inevitable damage of components. Here, we report high-temperature operating, flexible supercapacitors (f-SCs) that can provide reliable power output and extreme durability under severe electrochemical, mechanical, and thermal conditions. The outstanding capacitive features (e.g., ∼40% enhancement of the rate capability and a maximum capacitances of 170 F g(-1) and 18.7 mF cm(-2) at 160 °C) are attributed to facilitated ion transport at elevated temperatures. Under high-temperature operation and/or a flexibility test in both static and dynamic modes at elevated temperatures >100 °C, the f-SCs showed extreme long-term stability of 100000 cycles (>93% of initial capacitance value) and mechanical durability after hundreds of bending cycles (at bend angles of 60-180°). Even at 120 °C, the versatile design of tandem serial and parallel f-SCs was demonstrated to provide both desirable energy and power requirements at high temperatures.
Fifty-Year Durability Evaluation of Posts Treated with Industrial Wood Preservatives
Stan T. Lebow; Patricia Lebow; Bessie Woodward; Grant T. Kirker; Rachel Arango
2015-01-01
Long-term durability data are needed to improve service life estimates for treated wood products used as critical structural supports in industrial applications. This article reports the durability of longleaf pine (Pinus palustris) posts pressure treated with ammoniacal copper arsenate (ACA), chromated copper arsenate (CCA), creosote, or...
A Study on a Prognosis Algorithm for PEMFC Lifetime Prediction based on Durability Tests
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Xian; Pisu, Pierluigi; Toops, Todd J
2010-01-01
Of the fuel cells being studied, the proton exchange membrane fuel cell (PEMFC) is viewed as the most promising for transportation. Yet until today, the commercialization of the PEMFC has not been widespread in spite of its large expectation. Poor long term performances or durability, and high production and maintenance costs account for the main reasons. For the final commercialization of fuel cell in transportation field, the durability issue must be addressed, while the costs should be further brought down. In the meantime, health-monitoring and prognosis techniques are of great significance in ensuring the normal operation of the fuel cellmore » and preventing or predicting its likely abrupt and catastrophic failure.« less
Norman, J C; McGee, M G; Fuqua, J M; Igo, S R; Turner, S A; Sterling, R; Urrutia, C O; Frazier, O H; Clay, W C; Chambers, J A
1983-02-01
A long-term, implantable, electrically actuated left ventricular assist system (THI/Gould LVAS) is being developed and characterized in vitro and in vivo for utilization in patients with end-stage heart disease. This system consists of five major components: a long-term, implantable blood pump (THI E-type ALVAD); an electrical-mechanical energy converter (Gould Model V); a control unit with batteries; a volume compensation system; and an external power supply and monitoring unit. Two of these components (blood pump and electrical-mechanical energy converter) have been integrated, and are undergoing chronic in vivo evaluations in calves. Thus far, 44 pneumatically and electrically actuated THI/Gould LVAS evaluations have been performed. This experience has resulted in greater than 6.5 years of actuation in vivo, with durations exceeding 1 year. System in vivo performance in terms of durability, mechanical reliability, hemodynamic effectiveness, and biocompatibility has been satisfactory. Demonstration of long-term (2-year) effectiveness in supporting the circulation is the ultimate goal.
NASA Technical Reports Server (NTRS)
Brinson, H. F.
1985-01-01
The utilization of adhesive bonding for composite structures is briefly assessed. The need for a method to determine damage initiation and propagation for such joints is outlined. Methods currently in use to analyze both adhesive joints and fiber reinforced plastics is mentioned and it is indicated that all methods require the input of the mechanical properties of the polymeric adhesive and composite matrix material. The mechanical properties of polymers are indicated to be viscoelastic and sensitive to environmental effects. A method to analytically characterize environmentally dependent linear and nonlinear viscoelastic properties is given. It is indicated that the methodology can be used to extrapolate short term data to long term design lifetimes. That is, the method can be used for long term durability predictions. Experimental results for near adhesive resins, polymers used as composite matrices and unidirectional composite laminates is given. The data is fitted well with the analytical durability methodology. Finally, suggestions are outlined for the development of an analytical methodology for the durability predictions of adhesively bonded composite structures.
Low Earth orbit atomic oxygen simulation for durability evaluation of solar reflector surfaces
NASA Technical Reports Server (NTRS)
Degroh, Kim K.; Banks, Bruce A.
1992-01-01
To evaluate the performance and durability of solar reflector surfaces in the atomic oxygen environment typical of low Earth orbit (LEO), one must expose the reflector surface either directly to LEO or to ground-laboratory atomic oxygen environments. Although actual LEO exposures are most desired, such opportunities are typically scarce, expensive, and of limited duration. As a result, ground-laboratory exposures must be relied upon as the most practical long-term durability evaluation technique. Plasma ashers are widely used as LEO simulation facilities by producing atomic oxygen environments for durability evaluation of potential spacecraft materials. Atomic oxygen arrival differs between ground and space exposure in that plasma asher exposure produces isotropic arrival and space solar tracking produces sweeping arrival. Differences in initial impact reaction probability occur, dependent upon the energy and species existing in these environments. Due to the variations in ground-laboratory and space atomic oxygen, quantification of in-space performance based on plasma asher testing is not straightforward. The various atomic oxygen interactions that can occur with reflector surfaces, such as undercutting in organic substrates at protective coating defect sites, ground-laboratory techniques recommended for evaluating the atomic oxygen durability of reflectors based on asher exposures, and computational techniques which make use of ground-laboratory atomic oxygen exposure to predict in-space LEO durability are addressed.
Worldwide flight and ground-based exposure of composite materials
NASA Technical Reports Server (NTRS)
Dexter, H. B.; Baker, D. J.
1984-01-01
The long-term durability of those advanced composite materials which are applicable to aircraft structures was discussed. The composite components of various military and commercial aircraft and helicopters were reviewed. Both ground exposure and flight service were assessed in terms of their impact upon composite structure durability. The ACEE Program is mentioned briefly.
Evaluation and Validation of Organic Materials for Advanced Stirling Convertors (ASCs): Overview
NASA Technical Reports Server (NTRS)
Shin, Euy-Sik Eugene
2015-01-01
Various organic materials are used as essential parts in Stirling Convertors for their unique properties and functionalities such as bonding, potting, sealing, thread locking, insulation, and lubrication. More efficient Advanced Stirling Convertors (ASC) are being developed for future space applications especially with a long mission cycle, sometimes up to 17 years, such as deep space exploration or lunar surface power or Mars rovers, and others. Thus, performance, durability, and reliability of those organics should be critically evaluated in every possible material-process-fabrication-service environment relations based on their mission specifications. In general, thermal stability, radiation hardness, outgassing, and material compatibility of the selected organics have been systematically evaluated while their process and fabrication conditions and procedures were being optimized. Service environment-simulated long term aging tests up to 4 years were performed as a function of temperature for durability assessment of the most critical organic material systems.
Durability, value, and reliability of selected electric powered wheelchairs.
Fass, Megan V; Cooper, Rory A; Fitzgerald, Shirley G; Schmeler, Mark; Boninger, Michael L; Algood, S David; Ammer, William A; Rentschler, Andrew J; Duncan, John
2004-05-01
To compare the durability, value, and reliability of selected electric powered wheelchairs (EPWs), purchased in 1998. Engineering standards tests of quality and performance. A rehabilitation engineering center. Fifteen EPWs: 3 each of the Jazzy, Quickie, Lancer, Arrow, and Chairman models. Not applicable. Wheelchairs were evaluated for durability (lifespan), value (durability, cost), and reliability (rate of repairs) using 2-drum and curb-drop machines in accordance with the standards of the American National Standards Institute and Rehabilitation Engineering and Assistive Technology Society of North America. The 5 brands differed significantly (P
Overview of ORNL/NRC programs addressing durability of concrete structures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Naus, D.J.; Oland, C.B.
1994-06-01
The role of reinforced concrete relative to its applications as either safety-related structures in nuclear power or engineered barriers of low-level radioactive waste disposal facilities is described. Factors that can affect the long-term durability of reinforced concrete are identified. Overviews are presented of the Structural Aging Program, which is addressing the aging management of safety-related concrete structures in nuclear power plants, and the Permeability Test Methods and Data Program, which is identifying pertinent data and information for use in performance assessments of engineered barriers for low-level radioactive waste disposal.
RECENT ADVANCES IN HIGH TEMPERATURE ELECTROLYSIS AT IDAHO NATIONAL LABORATORY: SINGLE CELL TESTS
DOE Office of Scientific and Technical Information (OSTI.GOV)
X. Zhang; J. E. O'Brien; R. C. O'Brien
2012-07-01
An experimental investigation on the performance and durability of single solid oxide electrolysis cells (SOECs) is under way at the Idaho National Laboratory. In order to understand and mitigate the degradation issues in high temperature electrolysis, single SOECs with different configurations from several manufacturers have been evaluated for initial performance and long-term durability. A new test apparatus has been developed for single cell and small stack tests from different vendors. Single cells from Ceramatec Inc. show improved durability compared to our previous stack tests. Single cells from Materials and Systems Research Inc. (MSRI) demonstrate low degradation both in fuel cellmore » and electrolysis modes. Single cells from Saint Gobain Advanced Materials (St. Gobain) show stable performance in fuel cell mode, but rapid degradation in the electrolysis mode. Electrolyte-electrode delamination is found to have significant impact on degradation in some cases. Enhanced bonding between electrolyte and electrode and modification of the microstructure help to mitigate degradation. Polarization scans and AC impedance measurements are performed during the tests to characterize the cell performance and degradation.« less
Durability assessment of recycled concrete aggregates for use in new concrete.
DOT National Transportation Integrated Search
2012-06-01
The primary goal of this research project was to investigate the long-term durability of concrete incorporating : recycled concrete aggregate (RCA) through accelerated laboratory testing. Overall it was found that modifications to : standard aggregat...
Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grin, A.; Lstiburek, J.
The goal of this research is to provide durable and long-term water management solutions using exterior insulating sheathing as part of the water management system. It is possible to tape or seal the joints in insulating sheathing to create a drainage plane and even an air control layer. There exists the material durability component of the tape as well as the system durability component being the taped insulating sheathing as the drainage plane. This measure guideline provides best practice and product recommendations from the interviewed contractors and homebuilders who collectively have a vast amount of experience. Three significant issues weremore » discussed with the group, which are required to make taped insulating sheathing a simple, long-term, and durable drainage plane: horizontal joints should be limited or eliminated wherever possible; where a horizontal joint exists use superior materials; and frequent installation inspection and regular trade training are required to maintain proper installation.« less
Carbon nanocages: a new support material for Pt catalyst with remarkably high durability.
Wang, Xiao Xia; Tan, Zhe Hua; Zeng, Min; Wang, Jian Nong
2014-03-24
Low durability is the major challenge hindering the large-scale implementation of proton exchange membrane fuel cell (PEMFC) technology, and corrosion of carbon support materials of current catalysts is the main cause. Here, we describe the finding of remarkably high durability with the use of a novel support material. This material is based on hollow carbon nanocages developed with a high degree of graphitization and concurrent nitrogen doping for oxidation resistance enhancement, uniform deposition of fine Pt particles, and strong Pt-support interaction. Accelerated degradation testing shows that such designed catalyst possesses a superior electrochemical activity and long-term stability for both hydrogen oxidation and oxygen reduction relative to industry benchmarks of current catalysts. Further testing under conditions of practical fuel cell operation reveals almost no degradation over long-term cycling. Such a catalyst of high activity, particularly, high durability, opens the door for the next-generation PEMFC for "real world" application.
NASA Astrophysics Data System (ADS)
Musaramthota, Vishal
Advanced composite materials have enabled the conventional aircraft structures to reduce weight, improve fuel efficiency and offer superior mechanical properties. In the past, materials such as aluminum, steel or titanium have been used to manufacture aircraft structures for support of heavy loads. Within the last decade or so, demand for advanced composite materials have been emerging that offer significant advantages over the traditional metallic materials. Of particular interest in the recent years, there has been an upsurge in scientific significance in the usage of adhesively bonded composite joints (ABCJ's). ABCJ's negate the introduction of stress risers that are associated with riveting or other classical techniques. In today's aircraft transportation market, there is a push to increase structural efficiency by promoting adhesive bonding to primary joining of aircraft structures. This research is focused on the issues associated with the durability and related failures in bonded composite joints that continue to be a critical hindrance to the universal acceptance of ABCJ's. Of particular interest are the short term strength, contamination and long term durability of ABCJ's. One of the factors that influence bond performance is contamination and in this study the influence of contamination on composite-adhesive bond quality was investigated through the development of a repeatable and scalable surface contamination procedure. Results showed an increase in the contaminant coverage area decreases the overall bond strength significantly. A direct correlation between the contaminant coverage area and the fracture toughness of the bonded joint was established. Another factor that influences bond performance during an aircraft's service life is its long term strength upon exposure to harsh environmental conditions or when subjected to severe mechanical loading. A test procedure was successfully developed in order to evaluate durability of ABCJ's comprising severe environmental conditioning, fatiguing in ambient air and a combination of both. The bonds produced were durable enough to sustain the tests cases mentioned above when conditioned for 8 weeks and did not experience any loss in strength. Specimens that were aged for 80 weeks showed a degradation of 10% in their fracture toughness when compared to their baseline datasets. The effect of various exposure times needs to be further evaluated to establish the relationship of durability that is associated with the fracture toughness of ABCJ's.
NASA Technical Reports Server (NTRS)
Zhu, Dongming
2014-01-01
Environmental barrier coatings (EBCs) and SiC/SiC ceramic matrix composites (CMCs) systems will play a crucial role in future turbine engines for hot-section component applications because of their ability to significantly increase engine operating temperatures, reduce engine weight and cooling requirements. The development of prime-reliant environmental barrier coatings is a key to enable the applications of the envisioned CMC components to help achieve next generation engine performance and durability goals. This paper will primarily address the performance requirements and design considerations of environmental barrier coatings for turbine engine applications. The emphasis is placed on current candidate environmental barrier coating systems for SiCSiC CMCs, their performance benefits and design limitations in long-term operation and combustion environments. Major technical barriers in developing advanced environmental barrier coating systems, the coating integrations with next generation CMC turbine components having improved environmental stability, cyclic durability and system performance will be described. The development trends for turbine environmental barrier coating systems by utilizing improved compositions, state-of-the-art processing methods, and simulated environment testing and durability modeling will be discussed.
Radionuclide Incorporation and Long Term Performance of Apatite Waste Forms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Jianwei; Lian, Jie; Gao, Fei
2016-01-04
This project aims to combines state-of-the-art experimental and characterization techniques with atomistic simulations based on density functional theory (DFT) and molecular dynamics (MD) simulations. With an initial focus on long-lived I-129 and other radionuclides such as Cs, Sr in apatite structure, specific research objectives include the atomic scale understanding of: (1) incorporation behavior of the radionuclides and their effects on the crystal chemistry and phase stability; (2) stability and microstructure evolution of designed waste forms under coupled temperature and radiation environments; (3) incorporation and migration energetics of radionuclides and release behaviors as probed by DFT and molecular dynamics (MD) simulations;more » and (4) chemical durability as measured in dissolution experiments for long term performance evaluation and model validation.« less
Long-Term Durability Analysis of a 100,000+ Hr Stirling Power Convertor Heater Head
NASA Technical Reports Server (NTRS)
Bartolotta, Paul A.; Bowman, Randy R.; Krause, David L.; Halford, Gary R.
2000-01-01
DOE and NASA have identified Stirling Radioisotope Power Systems (SRPS) as the power supply for deep space exploration missions the Europa Orbiter and Solar Probe. As a part of this effort, NASA has initiated a long-term durability project for critical hot section components of the Stirling power convertor to qualify flight hardware. This project will develop a life prediction methodology that utilizes short-term (t < 20,000 hr) test data to verify long-term (t > 100,000 hr) design life. The project consists of generating a materials database for the specific heat of alloy, evaluation of critical hermetic sealed joints, life model characterization, and model verification. This paper will describe the qualification methodology being developed and provide a status for this effort.
Long-term Outcomes of Bariatric Surgery: A National Institutes of Health Symposium
Courcoulas, Anita P.; Yanovski, Susan Z.; Bonds, Denise; Eggerman, Thomas L.; Horlick, Mary; Staten, Myrlene A.; Arterburn, David E.
2017-01-01
Importance The clinical evidence base demonstrating bariatric surgery’s health benefits is much larger than it was when the NIH last held a Consensus Panel in 1991. Still, it remains unclear whether ongoing studies will address critical questions about long-term complication rates and the sustainability of weight loss and comorbidity control. Objective The National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK) and the National Heart, Lung, and Blood Institute (NHLBI) convened a multidisciplinary workshop in May 2013 to summarize the current state of knowledge of bariatric surgery, review research findings on the long-term outcomes of bariatric surgery, and establish priorities for future research directions. Evidence Review The evidence presented at the workshop was selected by the planning committee for both its quality and duration of follow up. The data review emphasized RCTs and large observational studies with long-term follow up, with or without a control group. Findings Several small RCTs showed greater weight loss and T2DM remission compared to non-surgical treatments within the first 2 years of follow-up after bariatric surgery. Large, long-term observational studies show durable (>5 years) weight loss, diabetes and lipid improvements with bariatric surgery. Still unclear are predictors of outcomes, long-term complications, long-term survival, micro- and macro-vascular events, mental health outcomes, and costs. The studies needed to address these knowledge gaps would be expensive and logistically difficult to perform. Conclusions and Relevance High-quality evidence shows that bariatric surgical procedures result in greater weight loss than non-surgical treatments and are more effective at inducing initial T2DM remission in obese patients. More information is needed about the long term durability of comorbidity control and complications after bariatric procedures and this evidence will most likely come from carefully designed observational studies. PMID:25271405
Survey of long-term durability of fiberglass reinforced plastic structures
NASA Technical Reports Server (NTRS)
Lieblein, S.
1981-01-01
Included are fluid containment vessels, marine structures, and aircraft components with up to 19 years of service. Correlations were obtained for the variation of static fatigue strength, cyclic fatigue strength, and residual burst strength for pressure vessels. In addition, data are presented for the effects of moisture on strength retention. Data variations were analyzed, and relationships and implications for testing are discussed. Change in strength properties for complete structures was examined for indications of the effects of environmental conditions such as moisture and outdoor exposure (ultraviolet radiation, weathering) on long term durability.
Kallaway, C; Humphreys, A; Laurence, N; Sutton, R
2016-11-01
INTRODUCTION The aim of this study was to evaluate the long-term outcome and durability of both autologous and implant-assisted latissimus dorsi reconstruction in a district general hospital over a 10-year follow-up period. METHODS A prospective cohort study was carried out using a detailed database of all latissimus dorsi flap reconstructions performed by a single consultant surgeon between 2003 and 2013 at the Royal United Hospital, Bath. The long-term outcome following reconstruction was assessed by analysing all episodes of 'reconstruction-specific' operations required from 6 months after the initial surgery. RESULTS The study included 110 patients with latissimus dorsi flap reconstructions, 21 autologous and 95 implant-assisted. Radiotherapy was given to 27 patients with reconstructed flaps. Mean follow-up was 69 months. Further reconstruction-specific surgery was needed in 27 (23%) cases, with 5 of these being post-radiotherapy flaps. Implant-related surgery was the most common reason for further surgery. Complications of the implant itself made up 52% of these cases, chronic sepsis being the most common. The rate of symptomatic capsular contracture requiring further surgery was 4.2%. Of these, one of four patients had undergone radiotherapy. DISCUSSION In our institution, latissimus dorsi reconstruction is durable and safe over the long term, with limited need for further substantial intervention to maintain a good outcome from the initial reconstruction. Autologous flaps were less likely to require further surgery over the long term compared with implant-based reconstructions. The low rate of symptomatic capsular contracture may be due to the protective mechanism provided by the extended harvest flap used.
Treatment for anal fissure: Is there a safe option?
Brady, Justin T; Althans, Alison R; Neupane, Ruel; Dosokey, Eslam M G; Jabir, Murad A; Reynolds, Harry L; Steele, Scott R; Stein, Sharon L
2017-10-01
Surgeons often approach anal fissure with chemical denervation (Botulinum toxin, BT) instead of initial lateral internal sphincterotomy (LIS) due to concerns for long-term incontinence. We evaluated the characteristics and outcomes of patients who received BT or LIS. We performed a retrospective chart review of patients undergoing LIS and BT for anal fissure between 2009 and 2015. In 2015, a telephone survey was performed to evaluate durability, long-term incontinence and patient satisfaction. Ninety-four patients met criteria: 73 LIS and 21 BT. Age (BT 49 vs. LIS 52) was similar between groups (p = 1.0). Cleveland Clinic Fecal Incontinence (CCFI) score pre-intervention was higher in BT than LIS patients (2.1 vs. 0.4, p = 0.007) with fewer BT patients with perfect continence (50% vs. 88%). Telephone survey response was 61%. Fissure recurrence was significantly higher for BT than LIS patients (36% vs. 9%, p = 0.03). Patients undergoing LIS were less likely to recur. Both LIS and BT patients had some durable changes in continence raising the question of whether there is a safe technique. Copyright © 2017 Elsevier Inc. All rights reserved.
Evaluation of the durability of composite tidal turbine blades.
Davies, Peter; Germain, Grégory; Gaurier, Benoît; Boisseau, Amélie; Perreux, Dominique
2013-02-28
The long-term reliability of tidal turbines is critical if these structures are to be cost effective. Optimized design requires a combination of material durability models and structural analyses. Composites are a natural choice for turbine blades, but there are few data available to predict material behaviour under coupled environmental and cycling loading. The present study addresses this problem, by introducing a multi-level framework for turbine blade qualification. At the material scale, static and cyclic tests have been performed, both in air and in sea water. The influence of ageing in sea water on fatigue performance is then quantified, and much lower fatigue lives are measured after ageing. At a higher level, flume tank tests have been performed on three-blade tidal turbines. Strain gauging of blades has provided data to compare with numerical models.
Physical-durable performance of concrete incorporating high loss on ignition-fly ash
NASA Astrophysics Data System (ADS)
Huynh, Trong-Phuoc; Ngo, Si-Huy; Hwang, Chao-Lung
2018-04-01
This study investigates the feasibility of using raw fly ash with a high loss on ignition in concrete. The fly ash-free concrete samples were prepared with different water-to-binder (w/b) ratios of 0.35, 0.40, and 0.45, whereas the fly ash concrete samples were prepared with a constant w/b of 0.40 and with various fly ash contents (10%, 20%, and 30%) as a cement substitution. The physical properties and durability performance of the concretes were evaluated through fresh concrete properties, compressive strength, strength efficiency of cement, ultrasonic pulse velocity, and resistance to sulfate attack. Test results show that the w/b ratio affected the concrete properties significantly. The incorporation of fly ash increased the workability and reduced the unit weight of fresh concrete. In addition, the fly ash concrete samples containing up to 20% fly ash exhibited an improved strength at long-term ages. Further, all of the fly ash concrete samples showed a good durability performance with ultrasonic pulse velocity value of greater than 4100 m/s and a comparable sulfate resistance to the no-fly ash concrete.
Fouling and long-term durability of an integrated forward osmosis and membrane distillation system.
Husnain, T; Mi, B; Riffat, R
2015-01-01
An integrated forward osmosis (FO) and membrane distillation (MD) system has great potential for sustainable wastewater reuse. However, the fouling and long-term durability of the system remains largely unknown. This study investigates the fouling behaviour and efficiency of cleaning procedures of FO and MD membranes used for treating domestic wastewater. Results showed that a significant decline in flux of both FO and MD membranes were observed during treatment of wastewater with organic foulants. However, shear force generated by the increased cross-flow physically removed the loosely attached foulants from the FO membrane surface and resulted in 86-88% recovery of flux by cleaning with tap water. For the MD membrane, almost no flux recovery was achieved due to adsorption of organic foulants on the hydrophobic membrane surface, thus indicating significant irreversible fouling/wetting, which may not be effectively cleaned even with chemical reagents. Long-term (10 d) tests showed consistent performance of the FO membrane by rejecting the contaminants. However, organic foulants reduced the hydrophobicity of the MD membrane, caused wetting problems and allowed contaminants to pass through. The results demonstrate that combination of the FO and MD processes can effectively reduce irreversible membrane fouling and solve the wetting problem of the MD membrane.
WOODSTOVE DURABILITY TESTING PROTOCOL
The report discusses the development of an accelerated laboratory test to simulate in-home woodstove aging and degradation. nown as a stress test, the protocol determines the long-term durability of woodstove models in a 1- to 2-week time frame. wo avenues of research have been t...
Carbon nanocages: A new support material for Pt catalyst with remarkably high durability
Wang, Xiao Xia; Tan, Zhe Hua; Zeng, Min; Wang, Jian Nong
2014-01-01
Low durability is the major challenge hindering the large-scale implementation of proton exchange membrane fuel cell (PEMFC) technology, and corrosion of carbon support materials of current catalysts is the main cause. Here, we describe the finding of remarkably high durability with the use of a novel support material. This material is based on hollow carbon nanocages developed with a high degree of graphitization and concurrent nitrogen doping for oxidation resistance enhancement, uniform deposition of fine Pt particles, and strong Pt-support interaction. Accelerated degradation testing shows that such designed catalyst possesses a superior electrochemical activity and long-term stability for both hydrogen oxidation and oxygen reduction relative to industry benchmarks of current catalysts. Further testing under conditions of practical fuel cell operation reveals almost no degradation over long-term cycling. Such a catalyst of high activity, particularly, high durability, opens the door for the next-generation PEMFC for “real world” application. PMID:24658614
DOE Office of Scientific and Technical Information (OSTI.GOV)
J. E. O'Brien; R. C. O'Brien; X. Zhang
2011-11-01
Performance characterization and durability testing have been completed on two five-cell high-temperature electrolysis stacks constructed with advanced cell and stack technologies. The solid oxide cells incorporate a negative-electrode-supported multi-layer design with nickel-zirconia cermet negative electrodes, thin-film yttria-stabilized zirconia electrolytes, and multi-layer lanthanum ferrite-based positive electrodes. The per-cell active area is 100 cm2. The stack is internally manifolded with compliant mica-glass seals. Treated metallic interconnects with integral flow channels separate the cells. Stack compression is accomplished by means of a custom spring-loaded test fixture. Initial stack performance characterization was determined through a series of DC potential sweeps in both fuel cellmore » and electrolysis modes of operation. Results of these sweeps indicated very good initial performance, with area-specific resistance values less than 0.5 ?.cm2. Long-term durability testing was performed with A test duration of 1000 hours. Overall performance degradation was less than 10% over the 1000-hour period. Final stack performance characterization was again determined by a series of DC potential sweeps at the same flow conditions as the initial sweeps in both electrolysis and fuel cell modes of operation. A final sweep in the fuel cell mode indicated a power density of 0.356 W/cm2, with average per-cell voltage of 0.71 V at a current of 50 A.« less
NASA Astrophysics Data System (ADS)
Xu, Xu; Li, Bincheng; He, Wenyan; Wang, Changjun; Wei, Ming
2018-04-01
Gemini-style protected-silver mirror (Sub / NiCrNx / Ag / NiCrNx / SiNx / Air) is a suitable choice for optical instruments requiring both long-term environmental durability and high broadband reflectance. Three Gemini-style protected-silver mirrors with NiCrNx interlayer thicknesses between 0.1 and 0.6 nm were prepared by magnetron sputtering, and the dependences of spectral properties and environmental durability of these protected-silver mirrors on the thickness of NiCrNx interlayer between the silver layer and SiNx layer were investigated in-depth. The reflectance, transmittance and total scattering loss measurements, optical microscope, and scanning electron microscope imaging were employed to characterize the spectral properties and surface morphology, and accelerated environmental tests, including humidity test and salt fog test, were applied to investigate the environmental durability. The experimental results showed that both optical and corrosion-resistant properties of protected-silver mirrors were NiCrNx interlayer thickness dependent, and an optimum NiCrNx interlayer thickness should be ˜0.3 nm for Gemini-style protected-silver mirrors to have reasonably both high reflectance in a broadband spectral range from visible to far infrared and good corrosion resistance for long-lifetime applications in harsh environments.
R. Sam Williams
2001-01-01
This report describes the long-term performance of painted window units that were placed outdoors near Madison, Wisconsin, in 1956. Covered in this report are the effects of the initial water repellent preservative (WRP) treatment during the first 6 years of exposure, a comparison of the water repellent effectiveness (WRE) ofthe WRP with the condition of the windows...
Brush Seal Performance and Durability Issues Based on T-700 Engine Test Results
NASA Technical Reports Server (NTRS)
Hendricks, R. C.
1994-01-01
The integrity and performance of brush seals have been established. Severe bench and engine tests have shown high initial wear or run-in rates, material smearing at the interface, and bristle and rub-runner wear, but the brush seals did not fail. Short-duration (46 hr) experimental T-700 engine testing of the compressor discharge seal established over 1-percent engine performance gain (brush versus labyrinth). Long-term gains were established only as leakage comparisons, with the brush at least 20 percent better at controlling leakage. Long-term materials issues, such as wear and ultimately seal life, remain to be resolved. Future needs are cited for materials and analysis tools that account for heat generation, thermomechanical behavior, and tribological pairing to enable original equipment manufacturers to design high-temperature, high-surface-speed seals with confidence.
Development of a Long-Life-Cycle, Highly Water-Resistant Solar Reflective Retrofit Roof Coating
DOE Office of Scientific and Technical Information (OSTI.GOV)
Polyzos, Georgios; Hunter, Scott; Sharma, Jaswinder
2016-03-04
Highly water-resistant and solar-reflective coatings for low-slope roofs are potentially among the most economical retrofit approaches to thermal management of the building envelope. Therefore, they represent a key building technology research program within the Department of Energy. Research efforts in industry and the Department of Energy are currently under way to increase long-term solar reflectance on a number of fronts. These include new polymer coatings technologies to provide longer-lasting solar reflectivity and improved test methodologies to predict long-term soiling and microbial performance. The focus on long-term improvements in soiling and microbial resistance for maximum reflectance does not address the singlemore » most important factor impacting the long-term sustainability of low-slope roof coatings: excellent water resistance. The hydrophobic character of asphaltic roof products makes them uniquely suitable for water resistance, but their low albedo and poor exterior durability are disadvantages. A reflective coating that maintains very high water resistance with increased long-term resistance to soiling and microbial activity would provide additional energy savings and extend roof service life.« less
Sustainability and durability analysis of reinforced concrete structures
NASA Astrophysics Data System (ADS)
Horáková, A.; Broukalová, I.; Kohoutková, A.; Vašková, J.
2017-09-01
The article describes an assessment of reinforced concrete structures in terms of durability and sustainable development. There is a short summary of findings from the literature on evaluation methods for environmental impacts and also about corrosive influences acting on the reinforced concrete structure, about factors influencing the durability of these structures and mathematical models describing the corrosion impacts. Variant design of reinforced concrete structure and assessment of these variants in terms of durability and sustainability was performed. The analysed structure was a concrete ceiling structure of a parking house for cars. The variants differ in strength class of concrete and thickness of concrete slab. It was found that in terms of durability and sustainable development it is significantly preferable to use higher class of concrete. There are significant differences in results of concrete structures durability for different mathematical models of corrosive influences.
Li, Qiang; Tong, Zichuan; Wang, Lefeng; Zhang, Jianjun; Ge, Yonggui; Wang, Hongshi; Li, Weiming; Xu, Li; Ni, Zhuhua
2013-01-01
Introduction With long-term follow-up, whether biodegradable polymer drug-eluting stents (DES) is efficient and safe in primary percutaneous coronary intervention (PCI) remains a controversial issue. This study aims to assess the long-term efficacy and safety of DES in PCI for ST-segment elevation myocardial infarction (STEMI). Material and methods A prospective, randomized single-blind study with 3-year follow-up was performed to compare biodegradable polymer DES with durable polymer DES in 332 STEMI patients treated with primary PCI. The primary end point was major adverse cardiac events (MACE) at 3 years after the procedure, defined as the composite of cardiac death, recurrent infarction, and target vessel revascularization. The secondary end points included in-segment late luminal loss (LLL) and binary restenosis at 9 months and cumulative stent thrombosis (ST) event rates up to 3 years. Results The rate of the primary end points and the secondary end points including major adverse cardiac events, in-segment late luminal loss, binary restenosis, and cumulative thrombotic event rates were comparable between biodegradable polymer DES and durable polymer DES in these 332 STEMI patients treated with primary PCI at 3 years. Conclusions Biodegradable polymer DES has similar efficacy and safety profiles at 3 years compared with durable polymer DES in STEMI patients treated with primary PCI. PMID:24482648
PROTOCOL TO EVALUATE THE MOISTURE DURABILITY OF ENERGY-EFFICIENT WALLS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boudreaux, Philip R; Pallin, Simon B; Hun, Diana E
Walls account for about 8% of the energy used in residential buildings. This energy penalty can be reduced with higher insulation levels and increased airtightness. However, these measures can compromise the moisture durability and long-term performance of wall assemblies because they can lead to lower moisture tolerance due to reduced drying potential. To avert these problems, a moisture durability protocol was developed to evaluate the probability that an energy-efficient wall design will experience mold growth. This protocol examines the effects of moisture sources in walls through a combination of simulations and lab experiments, uses the mold growth index as themore » moisture durability indicator, and is based on a probabilistic approach that utilizes stochastically varying input parameters. The simulation tools used include a new validated method for taking into account the effects of air leakage in wall assemblies This paper provides an overview of the developed protocol, discussion of the probabilistic simulation approach and describes results from the evaluation of two wall assemblies in Climate Zones 2, 4, and 6. The protocol will be used to supply builders with wall designs that are energy efficient, moisture durable and cost-effective.« less
Wang, An-Liang; Xu, Han; Feng, Jin-Xian; Ding, Liang-Xin; Tong, Ye-Xiang; Li, Gao-Ren
2013-07-24
Low cost, high activity, and long-term durability are the main requirements for commercializing fuel cell electrocatalysts. Despite tremendous efforts, developing non-Pt anode electrocatalysts with high activity and long-term durability at low cost remains a significant technical challenge. Here we report a new type of hybrid Pd/PANI/Pd sandwich-structured nanotube array (SNTA) to exploit shape effects and synergistic effects of Pd-PANI composites for the oxidation of small organic molecules for direct alcohol fuel cells. These synthesized Pd/PANI/Pd SNTAs exhibit significantly improved electrocatalytic activity and durability compared with Pd NTAs and commercial Pd/C catalysts. The unique SNTAs provide fast transport and short diffusion paths for electroactive species and high utilization rate of catalysts. Besides the merits of nanotube arrays, the improved electrocatalytic activity and durability are especially attributed to the special Pd/PANI/Pd sandwich-like nanostructures, which results in electron delocalization between Pd d orbitals and PANI π-conjugated ligands and in electron transfer from Pd to PANI.
Mitamura, Yoshinori; Takahashi, Sayaka; Amari, Shuichi; Okamoto, Eiji; Murabayashi, Shun; Nishimura, Ikuya
2011-03-01
A magnetic fluid (MF) seal enables mechanical contact-free rotation of the shaft and hence has excellent durability. The performance of an MF seal, however, has been reported to decrease in liquids. We developed an MF seal that has a "shield" mechanism, and a new MF with a higher magnetization of 47.9 kA/m. The sealing performance of the MF seal installed in a rotary blood pump was studied. Three types of MF seals were used. Seal A was a conventional seal without a shield. Seal B had the same structure as that of Seal A, but the seal was installed at 1 mm below liquid level. Seal C was a seal with a shield and the MF was set at 1 mm below liquid level. Seal A failed after 6 and 11 days. Seal B showed better results (20 and 73 days). Seal C showed long-term durability (217 and 275 days). The reason for different results in different seal structures was considered to be different flow conditions near the magnetic fluid. Fluid dynamics near the MF in the pump were analyzed using computational fluid dynamics (CFD) software. We have developed an MF seal with a shield that works in liquid for >275 days. The MF seal is promising as a shaft seal for rotary blood pumps.
NASA Astrophysics Data System (ADS)
2017-09-01
9th international conference on fibre reinforced concretes (FRC), textile reinforced concretes (TRC) and ultra-high performance concretes (UHPC) Preface The Fibre Concrete Conference series is held biennially to provide a platform to share knowledge on fibre reinforced concretes, textile concretes and ultra-high performance concretes regarding material properties and behaviour, technology procedures, topics of long-term behaviour, creep, durability; sustainable aspects of concrete including utilisation of waste materials in concrete production and recycling of concrete. The tradition of Fibre Concrete Conferences started in eighties of the last century. Nowadays the conference is organized by the Department of Concrete and Masonry Structures of the Czech Technical University in Prague, Faculty of Civil Engineering. The 9th International Conference Fibre Concrete 2017 had 109 participants from 27 countries all over the world. 55 papers were presented including keynote lectures of Professor Bažant, Professor Bartoš and Dr. Broukalová. The conference program covered wide range of topics from scientific research to practical applications. The presented contributions related to performance and behaviour of cement based composites, their long-term behaviour and durability, sustainable aspects, advanced analyses of structures from these composites and successful applications. This conference was organized also to honour Professor Zděnek P. Bažant on the occasion of his jubilee and to appreciate his merits and discoveries in the field of fibre reinforced composites, structural mechanics and engineering.
Habitats and Surface Construction Technology and Development Roadmap
NASA Technical Reports Server (NTRS)
Cohen, Marc; Kennedy, Kriss J.
1997-01-01
The vision of the technology and development teams at NASA Ames and Johnson Research Centers is to provide the capability for automated delivery and emplacement of habitats and surface facilities. The benefits of the program are as follows: Composites and Inflatables: 30-50% (goal) lighter than Al Hard Structures; Capability for Increased Habitable Volume, Launch Efficiency; Long Term Growth Potential; and Supports initiation of commercial and industrial expansion. Key Habitats and Surface Construction (H&SC) technology issues are: Habitat Shell Structural Materials; Seals and Mechanisms; Construction and Assembly: Automated Pro-Deploy Construction Systems; ISRU Soil/Construction Equipment: Lightweight and Lower Power Needs; Radiation Protection (Health and Human Performance Tech.); Life Support System (Regenerative Life Support System Tech.); Human Physiology of Long Duration Space Flight (Health and Human Performance Tech.); and Human Psychology of Long Duration Space Flight (Health and Human Performance Tech.) What is being done regarding these issues?: Use of composite materials for X-38 CRV, RLV, etc.; TransHAB inflatable habitat design/development; Japanese corporations working on ISRU-derived construction processes. What needs to be done for the 2004 Go Decision?: Characterize Mars Environmental Conditions: Civil Engineering, Material Durability, etc.; Determine Credibility of Inflatable Structures for Human Habitation; and Determine Seal Technology for Mechanisms and Hatches, Life Cycle, and Durability. An overview encompassing all of the issues above is presented.
Djian-Caporalino, Caroline; Palloix, Alain; Fazari, Ariane; Marteu, Nathalie; Barbary, Arnaud; Abad, Pierre; Sage-Palloix, Anne-Marie; Mateille, Thierry; Risso, Sabine; Lanza, Roger; Taussig, Catherine; Castagnone-Sereno, Philippe
2014-02-22
Resistant cultivars are key elements for pathogen control and pesticide reduction, but their repeated use may lead to the emergence of virulent pathogen populations, able to overcome the resistance. Increased research efforts, mainly based on theoretical studies, explore spatio-temporal deployment strategies of resistance genes in order to maximize their durability. We evaluated experimentally three of these strategies to control root-knot nematodes: cultivar mixtures, alternating and pyramiding resistance genes, under controlled and field conditions over a 3-years period, assessing the efficiency and the durability of resistance in a protected crop rotation system with pepper as summer crop and lettuce as winter crop. The choice of the resistance gene and the genetic background in which it is introgressed, affected the frequency of resistance breakdown. The pyramiding of two different resistance genes in one genotype suppressed the emergence of virulent isolates. Alternating different resistance genes in rotation was also efficient to decrease virulent populations in fields due to the specificity of the virulence and the trapping effect of resistant plants. Mixing resistant cultivars together appeared as a less efficient strategy to control nematodes. This work provides experimental evidence that, in a cropping system with seasonal sequences of vegetable species, pyramiding or alternating resistance genes benefit yields in the long-term by increasing the durability of resistant cultivars and improving the long-term control of a soil-borne pest. To our knowledge, this result is the first one obtained for a plant-nematode interaction, which helps demonstrate the general applicability of such strategies for breeding and sustainable management of resistant cultivars against pathogens.
2014-01-01
Background Resistant cultivars are key elements for pathogen control and pesticide reduction, but their repeated use may lead to the emergence of virulent pathogen populations, able to overcome the resistance. Increased research efforts, mainly based on theoretical studies, explore spatio-temporal deployment strategies of resistance genes in order to maximize their durability. We evaluated experimentally three of these strategies to control root-knot nematodes: cultivar mixtures, alternating and pyramiding resistance genes, under controlled and field conditions over a 3-years period, assessing the efficiency and the durability of resistance in a protected crop rotation system with pepper as summer crop and lettuce as winter crop. Results The choice of the resistance gene and the genetic background in which it is introgressed, affected the frequency of resistance breakdown. The pyramiding of two different resistance genes in one genotype suppressed the emergence of virulent isolates. Alternating different resistance genes in rotation was also efficient to decrease virulent populations in fields due to the specificity of the virulence and the trapping effect of resistant plants. Mixing resistant cultivars together appeared as a less efficient strategy to control nematodes. Conclusions This work provides experimental evidence that, in a cropping system with seasonal sequences of vegetable species, pyramiding or alternating resistance genes benefit yields in the long-term by increasing the durability of resistant cultivars and improving the long-term control of a soil-borne pest. To our knowledge, this result is the first one obtained for a plant-nematode interaction, which helps demonstrate the general applicability of such strategies for breeding and sustainable management of resistant cultivars against pathogens. PMID:24559060
Sensors Enable Plants to Text Message Farmers
NASA Technical Reports Server (NTRS)
2013-01-01
Long-term human spaceflight means long-term menu planning. Since every pound of cargo comes with a steep price tag, NASA has long researched technologies and techniques to allow astronauts to grow their own food, both on the journey and in some cases at their destination. Sustainable food technologies designed for space have resulted in spinoffs that improve the nutrition, safety, and durability of food on Earth. There are of course tradeoffs involved in making astronauts part-time farmers. Any time spent tending plants is time that can t be spent elsewhere: collecting data, exploring, performing routine maintenance, or sleeping. And as scarce as time is for astronauts, resources are even more limited. It is highly practical, therefore, to ensure that farming in space is as automated and precise as possible.
Subliminal words durably affect neuronal activity.
Gaillard, Raphaël; Cohen, Laurent; Adam, Claude; Clemenceau, Stéphane; Hasboun, Dominique; Baulac, Michel; Willer, Jean-Claude; Dehaene, Stanislas; Naccache, Lionel
2007-10-08
Unconscious mental representations elicited by subliminal stimuli are marked by their fleeting lifetimes, usually below 1 s. Can such evanescent subliminal stimuli, nevertheless, lead to long-lasting learning? To date, evidence suggesting a long-term influence of briefly perceived stimuli on behaviour or brain activity is scarce and questionable. In this study, we used intracranial recordings to provide the first direct demonstration that unconsciously perceived subliminal words could exert long-lasting effects on neuronal signals. When repeating subliminal words over long interstimulus intervals, we observed electrophysiological repetition effects. These unconscious repetition effects suggest that the single presentation of a masked word can durably affect neural architecture.
Enhancing composite durability : using thermal treatments
Jerrold E. Winandy; W. Ramsay Smith
2007-01-01
The use of thermal treatments to enhance the moisture resistance and aboveground durability of solid wood materials has been studied for years. Much work was done at the Forest Products Laboratory in the last 15 years on the fundamental process of both short-and long-term exposure to heat on wood materials and its interaction with various treatment chemicals. This work...
DOT National Transportation Integrated Search
2009-01-01
There is increasing pressure from owners, contractors, and the public to open bridge decks sooner to full : traffic loads. As a result, a set of criteria or guidelines is needed to determine when concrete bridge decks can : safely be opened. Today, c...
Tcholakian, Robert K.; Raad, Issam I.
2001-01-01
This study was performed to test the long-term antimicrobial efficacy of impregnated silicone catheters comprising an antimicrobial layer sandwiched between an external surface sheath and a luminal surface silicone sheath. The design of the catheter permits the introduction of various antimicrobials in addition to anticoagulants or antifibrins in the antimicrobial layer and allows their gradual release over a period of months after insertion. The in vitro data presented show that the catheter can provide antimicrobial activity for 90 days, after being replated for 15 7-day cycles of replating. When the catheters were immersed in human serum and incubated at 37°C, they demonstrated significant antimicrobial activity after more than 325 days of incubation. The significant long-term in vitro antimicrobial activity observed may imply effective in vivo activity for almost 1 year after insertion and could serve as a cost-effective alternative to surgically implantable silicone catheters. PMID:11408213
Extended Durability Testing of an External Fuel Processor for a Solid Oxide Fuel Cell (SOFC)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mark Perna; Anant Upadhyayula; Mark Scotto
2012-11-05
Durability testing was performed on an external fuel processor (EFP) for a solid oxide fuel cell (SOFC) power plant. The EFP enables the SOFC to reach high system efficiency (electrical efficiency up to 60%) using pipeline natural gas and eliminates the need for large quantities of bottled gases. LG Fuel Cell Systems Inc. (formerly known as Rolls-Royce Fuel Cell Systems (US) Inc.) (LGFCS) is developing natural gas-fired SOFC power plants for stationary power applications. These power plants will greatly benefit the public by reducing the cost of electricity while reducing the amount of gaseous emissions of carbon dioxide, sulfur oxides,more » and nitrogen oxides compared to conventional power plants. The EFP uses pipeline natural gas and air to provide all the gas streams required by the SOFC power plant; specifically those needed for start-up, normal operation, and shutdown. It includes a natural gas desulfurizer, a synthesis-gas generator and a start-gas generator. The research in this project demonstrated that the EFP could meet its performance and durability targets. The data generated helped assess the impact of long-term operation on system performance and system hardware. The research also showed the negative impact of ambient weather (both hot and cold conditions) on system operation and performance.« less
Durability of aircraft composite materials
NASA Technical Reports Server (NTRS)
Dextern, H. B.
1982-01-01
Confidence in the long term durability of advanced composites is developed through a series of flight service programs. Service experience is obtained by installing secondary and primary composite components on commercial and military transport aircraft and helicopters. Included are spoilers, rudders, elevators, ailerons, fairings and wing boxes on transport aircraft and doors, fairings, tail rotors, vertical fins, and horizontal stabilizers on helicopters. Materials included in the evaluation are boron/epoxy, Kevlar/epoxy, graphite/epoxy and boron/aluminum. Inspection, maintenance, and repair results for the components in service are reported. The effects of long term exposure to laboratory, flight, and outdoor environmental conditions are reported for various composite materials. Included are effects of moisture absorption, ultraviolet radiation, and aircraft fuels and fluids.
Chen, Lanlan; Ren, Xiang; Teng, Wanqing; Shi, Pengfei
2017-07-21
Electrolytic hydrogen generation needs earth-abundant oxygen evolution reaction electrocatalysts that perform efficiently at mild pH. Here, the development of amorphous nickel-cobalt-borate nanosheet arrays on macroporous nickel foam (NiCo-Bi/NF) as a 3D catalyst electrode for high-performance water oxidation in near-neutral media is reported. To drive a current density of 10 mA cm -2 , the resulting NiCo-Bi/NF demands an overpotential of only 430 mV in 0.1 m potassium borate (K-Bi, pH 9.2). Moreover, it also shows long-term electrochemical durability with maintenance of catalytic activity for 20 h, achieving a high turnover frequency of 0.21 s -1 at an overpotential of 550 mV. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Environmental Barrier Coatings for Turbine Engines: A Design and Performance Perspective
NASA Technical Reports Server (NTRS)
Zhu, Dongming; Fox, Dennis S.; Ghosn, Louis; Smialek, James L.; Miller, Robert A.
2009-01-01
Ceramic thermal and environmental barrier coatings (TEBC) for SiC-based ceramics will play an increasingly important role in future gas turbine engines because of their ability to effectively protect the engine components and further raise engine temperatures. However, the coating long-term durability remains a major concern with the ever-increasing temperature, strength and stability requirements in engine high heat-flux combustion environments, especially for highly-loaded rotating turbine components. Advanced TEBC systems, including nano-composite based HfO2-aluminosilicate and rare earth silicate coatings are being developed and tested for higher temperature capable SiC/SiC ceramic matrix composite (CMC) turbine blade applications. This paper will emphasize coating composite and multilayer design approach and the resulting performance and durability in simulated engine high heat-flux, high stress and high pressure combustion environments. The advances in the environmental barrier coating development showed promise for future rotating CMC blade applications.
NASA Astrophysics Data System (ADS)
Qu, Jing
Conjugated polymers such as poly(3,4-ethylenedioxythiophene) (PEDOT) are of interest for a variety of applications including interfaces between electronic biomedical devices and living tissue. These polymers provide an improved interface compared to metal and semiconducting electrodes because of their ionic conductivity, relatively lower stiffness, and ability to incorporate biological molecules. Even though the signal transfer and biocompatibility of conjugated polymers are superior compared as the biointerfacing materials, the durability has been the weakest part for the long-term applications. Even though some efforts have been made to improve the durability of conjugated polymers, little quantitative information of the improved cohesion, adhesion and durability has been reported. In this thesis, the methods of improving the durability of conjugated polymer films, especially PEDOT, were investigated, including alternating the processing methods and components in synthesis. The 7-month in vivo testing showed that the durability of PEDOT films still needed to be improved. As a coating for biosignal transfer, the cohesion, adhesion and electrochemical stability of PEDOT are vital to determine the long-term performance. Not much information hd been developed around the cohesion and adhesion. A thin film cracking method was developed to measure the stiffness, strength and the interfacial shear strength (adhesion) of electrochemically deposited PEDOT. The estimated Young’s modulus of the PEDOT films was 2.6 ± 1.4 GPa, and the strain to failure was around 2%. The tensile strength was measured to be 56 ± 27 MPa. The effectiveness of crosslinker and adhesion promoter was demonstrated by this method. It was shown that 5 mole% addition of a tri-functional EDOT crosslinker (EPh) increased the tensile strength of the films to 283 ± 67 MPa, while the strain to failure remained about the same (2%). With the modification of EDOT-acid to the surface of stainless steel substrate, the interfacial shear strength was improved from 11.8 MPa to 32.5 MPa. To correlate the adhesion with the durability of PEDOT coatings, a tribology test was introduced. It was found that the durability of PEDOT on Au electrode was much exceptionally good, and even better than the adhesion promoted coatings with EDOT-acid on stainless steel and ITO substrates. The characterization method developed in this thesis made a critical difference in systematically comparing different materials, and provided valuable information for materials development and selection.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neuhauser, K.
Through discussion of five case studies (test homes), this project evaluates strategies to elevate the performance of existing homes to a level commensurate with best-in-class implementation of high-performance new construction homes. The test homes featured in this research activity participated in Deep Energy Retrofit (DER) Pilot Program sponsored by the electric and gas utility National Grid in Massachusetts and Rhode Island. Building enclosure retrofit strategies are evaluated for impact on durability and indoor air quality in addition to energy performance. Evaluation of strategies is structured around the critical control functions of water, airflow, vapor flow, and thermal control. The aimmore » of the research project is to develop guidance that could serve as a foundation for wider adoption of high performance, 'deep' retrofit work. The project will identify risk factors endemic to advanced retrofit in the context of the general building type, configuration and vintage encountered in the National Grid DER Pilot. Results for the test homes are based on observation and performance testing of recently completed projects. Additional observation would be needed to fully gauge long-term energy performance, durability, and occupant comfort.« less
Rodney C. De Groot; Douglas M. Crawford; Jack Norton; John Keith
2000-01-01
The durability of preservative-treated stakes of second-growth Coastal Douglas-fir was evaluated in a field plot in northern Queensland, Australia. Results from this field trial indicate that second-growth Douglas-fir can be treated with preservatives to meet Australian standards and will provide long-term durability in adverse environments. Data presented indicate...
Barber, Sean M; Rangel-Castilla, Leonardo; Zhang, Y Jonathan; Klucznik, Richard; Diaz, Orlando
2015-10-01
Endovascular therapy is the preferred treatment for most carotid-cavernous fistulas (CCFs). Early reports have documented excellent initial clinical and radiographic outcomes after embolization of CCFs with Onyx or n-butyl cyanoacrylate (n-BCA), but little evidence is available about the long-term durability of this technique. To characterize the long-term durability of CCF liquid embolization. The authors retrospectively reviewed a database of 24 CCFs in 21 consecutive patients who underwent Onyx or n-BCA embolization of a CCF from 2006 to 2013 at our institution. A total of 25 Onyx or n-BCA embolization procedures were attempted and 24 successfully completed during the study, resulting in complete or near-complete occlusion by the end of the study in all 24 CCFs (obliteration success, 100%). Attempted embolization in a single CCF failed initially, but was performed successfully at a later date by a different approach. None of the 24 CCFs recanalized, regrew, or required any further treatment subsequent to Onyx or n-BCA embolization throughout a mean 12.4 months of angiographic follow-up (range 1-36 months). Clinically significant complications were seen in three embolization procedures, including cranial nerve palsies (n=1), embolic infarct (n=1), and intraperitoneal hemorrhage (n=1). Early evidence has indicated that endovascular embolization with Onyx is relatively safe and effective at achieving an initial angiographic cure for CCFs. Results of our series suggest that angiographic and clinical outcomes of Onyx and n-BCA embolization remain stable at mid- and long-term follow-up. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Kim, S M; Jung, I M; Han, A; Min, S-I; Lee, T; Ha, J; Kim, S J; Min, S-K
2015-08-01
Middle aortic syndrome (MAS) is a rare condition characterized by severe stenosis of the distal thoracic or abdominal aorta. The aims of this study are to define the anatomic characteristics of MAS and to review the various surgical methods and their outcomes in terms of long-term durability Ten adult patients were diagnosed with MAS caused by Takayasu arteritis (TA) or midaortic dysplastic syndrome and underwent surgical treatment between July 1992 and January 2013. The aortic lesions were mostly suprarenal (n = 7) and stenoses were commonly found in the celiac axis (n = 6), SMA (n = 7), and renal artery (n = 6). Indications for operation were uncontrolled hypertension in six patients and lower extremity claudication in four. Eight aortic bypasses, one supraceliac aortic interposition graft, and one bilateral aorto-renal bypass were performed. Adjunctive renal bypass with saphenous vein graft (n = 4) and IMA reimplantation (n = 2) were performed simultaneously. There was no post-operative mortality, and one complication of iliac dissection at the distal anastomosis site was detected and treated by stenting. Hypertension was cured or improved in five of the six patients, and lower extremity claudication improved in all of them. With a median follow up of 60 months (range, 12-263), all the aortic bypasses were patent and one adjunctive renal artery bypass graft with aortic bypass was occluded 29 months post-operatively. Aortic bypass for MAS is safe and shows excellent long-term durability. Considering the patients are relatively young with a long life expectancy, aggressive surgical treatment could be beneficial. Lifelong follow up to monitor complications and disease progression is necessary. Copyright © 2015 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Compact and Lightweight Sabatier Reactor for Carbon Dioxide Reduction
NASA Technical Reports Server (NTRS)
Junaedi, Christian; Hawley, Kyle; Walsh, Dennis; Roychoudhury, Subir; Abney, Morgan B.; Perry, Jay L.
2011-01-01
The utilization of CO2 to produce life support consumables, such as O2 and H2O, via the Sabatier reaction is an important aspect of NASA s cabin Atmosphere Revitalization System and In-Situ Resource Utilization architectures for both low-earth orbit and long-term manned space missions. In the current International Space Station (ISS) and other low orbit missions, metabolically-generated CO2 is removed from the cabin air and vented into space, resulting in a net loss of O2. This requires a continuous resupply of O2 via water electrolysis, and thus highlights the need for large water storage capacity. For long-duration space missions, the amount of life support consumables is limited and resupply options are practically nonexistent, thus atmosphere resource management and recycle becomes crucial to significantly reduce necessary O2 and H2O storage. Additionally, the potential use of the Martian CO2-rich atmosphere and Lunar regolith to generate life support consumables and propellant fuels is of interest to NASA. Precision Combustion, Inc. (PCI) has developed a compact, lightweight Microlith(Registered TradeMark)-based Sabatier (CO2 methanation) reactor which demonstrates the capability of achieving high CO2 conversion and near 100% CH4 selectivity at space velocities of 30,000-60,000 hr-1. The combination of the Microlith(Registered TradeMark) substrates and durable, novel catalyst coating permitted efficient Sabatier reactor operation that favors high reactant conversion, high selectivity, and long-term durability. This paper presents the reactor development and performance results at various operating conditions. Additionally, results from 100-hr durability tests and mechanical vibration tests are discussed.
Long-term benefit of PD-L1 blockade in lung cancer associated with JAK3 activation
Van Allen, Eliezer M.; Golay, Hadrien G.; Liu, Yan; Koyama, Shohei; Wong, Karrie; Taylor-Weiner, Amaro; Giannakis, Marios; Harden, Maegan; Rojas-Rudilla, Vanesa; Chevalier, Aaron; Thai, Tran; Lydon, Christine; Mach, Stacy; Wong, Joshua A.; Rabin, Alexandra R.; Helmkamp, Joshua; Sholl, Lynette; Carter, Scott L.; Oxnard, Geoffrey; Janne, Pasi; Getz, Gad; Lindeman, Neal; Hammerman, Peter S.; Garraway, Levi A.; Hodi, F. Stephen; Rodig, Scott; Dranoff, Glenn; Wong, Kwok-Kin; Barbie, David A.
2015-01-01
PD-1 immune checkpoint blockade occasionally results in durable clinical responses in advanced metastatic cancers. However, mechanism-based predictors of response to this immunotherapy remain incompletely characterized. We performed comprehensive genomic profiling on a tumor and germline sample from a patient with refractory lung adenocarcinoma who achieved marked long-term clinical benefit from anti-PD-L1 therapy. We discovered activating somatic and germline amino acid variants in JAK3 that promoted PD-L1 induction in lung cancer cells and in the tumor immune microenvironment. These findings suggest that genomic alterations that deregulate cytokine receptor signal transduction could contribute to PD-L1 activation and engagement of the PD-1 immune checkpoint in lung cancer. PMID:26014096
Space life support engineering program
NASA Technical Reports Server (NTRS)
Seagrave, Richard C.
1991-01-01
This report covers the first six months of work performed under the NASA University Grant awarded to Iowa State University to perform research on two topics relating to the development of closed-loop long-term life support systems. A comprehensive study to develop software to simulate the dynamic operation of water reclamation systems in long-term closed-loop life support systems is being carried out as part of an overall program for the design of systems for a Mars voyage. This project is being done in parallel with a similar effort in the Department of Chemistry to develop durable accurate low-cost sensors for monitoring of trace chemical and biological species in recycled water supplies. Aspen-Plus software is being used on a group of high-performance workstations to develop the steady state descriptions for a number of existing technologies. Following completion, a dynamic simulation package will be developed for determining the response of such systems to changes in the metabolic needs of the crew and to upsets in system hardware performance.
Long term durability of solid heartwood stakes treated with ACA or CCA
Mark E. Mankowski; Stan Lebow; Grant Kirker; Lee Gjovik
2017-01-01
Limited long-term field data exist evaluating the benefit of chemical wood preservatives on refractory wood species with abundant heartwood. The objective of this study was to determine the effectiveness of preservative-treated refractory solid heartwood comprised of southern pine, Douglas-fir, or Engelmann spruce. Non-incised and incised solid lumber of these species...
NASA Technical Reports Server (NTRS)
Zhu, Dongming; Ghosn, Louis J.
2015-01-01
Advanced environmental barrier coating (EBC) systems for low emission SiCSiC CMC combustors and turbine airfoils have been developed to meet next generation engine emission and performance goals. This presentation will highlight the developments of NASAs current EBC system technologies for SiC-SiC ceramic matrix composite combustors and turbine airfoils, their performance evaluation and modeling progress towards improving the engine SiCSiC component temperature capability and long-term durability. Our emphasis has also been placed on the fundamental aspects of the EBC-CMC creep and fatigue behaviors, and their interactions with turbine engine oxidizing and moisture environments. The EBC-CMC environmental degradation and failure modes, under various simulated engine testing environments, in particular involving high heat flux, high pressure, high velocity combustion conditions, will be discussed aiming at quantifying the protective coating functions, performance and durability, and in conjunction with damage mechanics and fracture mechanics approaches.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Won, Jong-Pil, E-mail: jpwon@konkuk.ac.kr; Hwang, Un-Jong; Lee, Su-Jin
This study evaluated the performance of shotcrete using high strength C{sub 12}A{sub 7} mineral-based accelerator that has been developed to improve the durability and long-term strength. Rebound, compressive strength and flexural strength were tested in the field. Test result showed that existing C{sub 12}A{sub 7} mineral-based accelerator exhibits better early strength than the high-strength C{sub 12}A{sub 7} mineral-based accelerator until the early age, but high-strength C{sub 12}A{sub 7} mineral-based accelerator shows about 29% higher at the long-term age of 28 days. Microstructural analysis such as scanning electron microscope (SEM), X-ray diffraction (XRD) and nitrogen adsorption method was evaluated to analyzemore » long-term strength development mechanism of high strength C{sub 12}A{sub 7} mineral-based accelerator. As analysis result, it had more dense structure due to the reaction product by adding material that used to enhanced strength. It had better resistance performance in chloride ion penetration, freezing–thawing and carbonation than shotcrete that used existing C{sub 12}A{sub 7} mineral-based accelerator.« less
NASA Astrophysics Data System (ADS)
Chen, Hui; Han, Shu-Yan; Liu, Rui-Heng; Chen, Teng-Fei; Bi, Kai-Lun; Liang, Jian-Bo; Deng, Yu-Heng; Wan, Chong-Qing
2018-02-01
Incorporating ionic liquids (abbreviated as ILs) into porous metal-organic framework (MOF) to obtain ILs@MOF nanocomposites is documented as a feasible method to achieve new type of anhydrous proton conductor with high performance. We newly synthesized a series of ILs with different acid counter anions (R-SO3-) and their ILs@MOF hybrid materials, i.e. SA-EIMS@MIL-101, MSA-EIMS@MIL-101 and PTSA-EIMS@MIL-101 (SA = sulfate acid, MSA = methanesulfonate acid, PTSA = p-toluenesulfonate acid, EIMS = 1-(1-ethyl-3-imidazolium)propane-3-sulfonate). Such hybrid materials displayed as anhydrous proton conduction with long-term durability even heated at 150 °C open to air. σ value of SA-EIMS@MIL-101 is up to 1.89 × 10-3 S cm-1, being in the range of the most conductive MOF-based materials. MOF support exhibited favorable proton transport and long-term retention for ILs. Anion volumes of R-SO3- displayed significant effects on the proton conductivity of such hybrid ILs@MOF materials. The smaller the van der Waals volume of R-SO3- is, the higher the conductivity of ILs@MOF is. This work suggests that the combination of a variety of the incorporated ILs and a MOF framework would afford high proton transport and gives an idea to explore the safe, anhydrous, solid-state electrolyte for high temperature proton exchange membrane fuel cell.
Peera, S Gouse; Arunchander, A; Sahu, A K
2016-08-14
Nitrogen and fluorine co-doped graphite nanofibers (N/F-GNF) and their cumulative effect with Fe and Co have been developed as an alternative non-precious metal catalyst for efficient oxygen reduction reaction (ORR) in acidic media. The synergistic effect between the doped hetero atoms and the co-ordinated Fe and Co towards ORR activity and durability of the catalyst is deeply investigated. A high ORR onset potential comparable with commercial Pt/C catalyst is observed with the Fe-Co/NF-GNF catalyst, which indicates that this catalyst is a potential alternative to Pt/C. A fivefold increase in mass activity is achieved by the Fe-Co/NF-GNF catalyst compared to the simple N/F-GNF catalyst, which endorses the significant role of transition metal atoms in enhancing ORR activity. The advanced Fe-Co/NF-GNF catalyst also exhibits complete tolerance to CH3OH and CO. The Fe-Co/NF-GNF catalyst also exhibits excellent durability towards the ORR with only a 10 mV negative shift in its half wave potential after a 10 000 repeated potential cycling test, whereas in the case of a commercial Pt/C catalyst there was an ∼110 mV negative shift under similar environmental conditions. More stringent corrosive test cycles were also performed by maintaining the cell as high as 1.4 V with a later decrease to 0.6 V vs. RHE for 300 cycles, which showed the excellent durability of the Fe-Co/NF-GNF catalyst in comparison with the Pt/C catalyst. XPS analysis of the Fe-Co/NF-GNF catalyst presents the ORR active chemical states of N (pyridinic-N and graphitic-N) and F (semi-ionic-F) and the co-ordinated sites of Fe and Co species with the dopants. The excellent performance and durability of the Fe-Co/NF-GNF catalyst is due to the synergistic effect between the hetero atoms dopants (N and F) and strong co-ordinating bonds of M-N-C, which protect the graphene layers around the metallic species and greatly mitigates the leaching of Co and Fe during the long term cycling test. The high activity and long term durability of the Fe-Co/NF-GNF catalyst make it a promising ORR electrocatalyst for the fuel cell cathode reaction.
Durability of high performance concrete in magnesium brine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tumidajski, P.J.; Chan, G.W.
1996-04-01
The durability of six concretes exposed to magnesium brine was monitored for 24 months. These concretes incorporated ground granulated blast furnace slag, silica fume, and fly ash. The Young`s moduli, chloride penetrations, and median pore diameters were measured. There was a cyclic nature to these properties due to the complicated interaction of hydration with magnesium, chloride and sulfate attack. Mineral admixtures, in combination with a long initial cure, provided the most durable concrete. Concrete with 65% slag had the best overall durability to the brines tested.
The operation of the century: total hip replacement.
Learmonth, Ian D; Young, Claire; Rorabeck, Cecil
2007-10-27
In the 1960s, total hip replacement revolutionised management of elderly patients crippled with arthritis, with very good long-term results. Today, young patients present for hip-replacement surgery hoping to restore their quality of life, which typically includes physically demanding activities. Advances in bioengineering technology have driven development of hip prostheses. Both cemented and uncemented hips can provide durable fixation. Better materials and design have allowed use of large-bore bearings, which provide an increased range of motion with enhanced stability and very low wear. Minimally invasive surgery limits soft-tissue damage and facilitates accelerated discharge and rehabilitation. Short-term objectives must not compromise long-term performance. Computer-assisted surgery will contribute to reproducible and accurate placement of implants. Universal economic constraints in healthcare services dictate that further developments in total hip replacement will be governed by their cost-effectiveness.
Time-Dependent Topology of Railway Prestressed Concrete Sleepers
NASA Astrophysics Data System (ADS)
Li, Dan; Ngamkhanong, Chayut; Kaewunruen, Sakdirat
2017-10-01
The railway sleepers are very important component of railway track structure. The sleepers can be manufactured by using timber, concrete, steel or other engineered materials. Nowadays, prestressed concrete has become most commonly used type of sleepers. Prestressed concrete sleepers have longer life-cycle and lower maintenance cost than reinforced concrete sleepers. They are expected to withstand high dynamic loads and harsh environments. However, durability and long-term performance of prestressed concrete sleepers are largely dependent on creep and shrinkage responses. This study investigates the long-term behaviours of prestressed concrete sleepers and proposes the shortening and deflection diagrams. Comparison between design codes of Eurocode 2 and AS3600-2009 provides the insight into the time-dependent performance of prestressed concrete sleepers. The outcome of this paper will improve the rail maintenance and inspection criteria in order to establish appropriate sensible remote track condition monitor network in practice.
NASA Technical Reports Server (NTRS)
Rutledge, Sharon K.
1999-01-01
Spacecraft in low Earth orbit (LEO) are subjected to many components of the environment, which can cause them to degrade much more rapidly than intended and greatly shorten their functional life. The atomic oxygen, ultraviolet radiation, and cross contamination present in LEO can affect sensitive surfaces such as thermal control paints, multilayer insulation, solar array surfaces, and optical surfaces. The LEO Spacecraft Materials Test (LEO-SMT) program is being conducted to assess the effects of simulated LEO exposure on current spacecraft materials to increase understanding of LEO degradation processes as well as to enable the prediction of in-space performance and durability. Using ground-based simulation facilities to test the durability of materials currently flying in LEO will allow researchers to compare the degradation evidenced in the ground-based facilities with that evidenced on orbit. This will allow refinement of ground laboratory test systems and the development of algorithms to predict the durability and performance of new materials in LEO from ground test results. Accurate predictions based on ground tests could reduce development costs and increase reliability. The wide variety of national and international materials being tested represent materials being functionally used on spacecraft in LEO. The more varied the types of materials tested, the greater the probability that researchers will develop and validate predictive models for spacecraft long-term performance and durability. Organizations that are currently participating in the program are ITT Research Institute (USA), Lockheed Martin (USA), MAP (France), SOREQ Nuclear Research Center (Israel), TNO Institute of Applied Physics (The Netherlands), and UBE Industries, Ltd. (Japan). These represent some of the major suppliers of thermal control and sensor materials currently flying in LEO. The participants provide materials that are exposed to selected levels of atomic oxygen, vacuum ultraviolet radiation, contamination, or synergistic combined environments at the NASA Lewis Research Center. Changes in characteristics that could affect mission performance or lifetime are then measured. These characteristics include changes in mass, solar absorptance, and thermal emittance. The durability of spacecraft materials from U.S. suppliers is then compared with those of materials from other participating countries. Lewis will develop and validate performance and durability prediction models using this ground data and available space data. NASA welcomes the opportunity to consider additional international participants in this program, which should greatly aid future spacecraft designers as they select materials for LEO missions.
Does visual short-term memory have a high-capacity stage?
Matsukura, Michi; Hollingworth, Andrew
2011-12-01
Visual short-term memory (VSTM) has long been considered a durable, limited-capacity system for the brief retention of visual information. However, a recent work by Sligte et al. (Plos One 3:e1699, 2008) reported that, relatively early after the removal of a memory array, a cue allowed participants to access a fragile, high-capacity stage of VSTM that is distinct from iconic memory. In the present study, we examined whether this stage division is warranted by attempting to corroborate the existence of an early, high-capacity form of VSTM. The results of four experiments did not support Sligte et al.'s claim, since we did not obtain evidence for VSTM retention that exceeded traditional estimates of capacity. However, performance approaching that observed in Sligte et al. can be achieved through extensive practice, providing a clear explanation for their findings. Our evidence favors the standard view of VSTM as a limited-capacity system that maintains a few object representations in a relatively durable form.
Comparison of cemented and uncemented fixation in total knee arthroplasty.
Brown, Thomas E; Harper, Benjamin L; Bjorgul, Kristian
2013-05-01
As a result of reading this article, physicians should be able to :1. Understand the rationale behind using uncemented fixation in total knee arthroplasty.2.Discuss the current literature comparing cemented and uncemented total knee arthroplasty3. Describe the value of radiostereographic analysis in assessing implant stability.4. Appreciate the limitations in the available literature advocating 1 mode of fixation in total knee arthroplasty. Total knee arthroplasty performed worldwide uses either cemented, cementless, or hybrid (cementless femur with a cemented tibia) fixation of the components. No recent literature review concerning the outcomes of cemented vs noncemented components has been performed. Noncemented components offer the potential advantage of a biologic interface between the bone and implants, which could demonstrate the greatest advantage in long-term durable fixation in the follow-up of young patients undergoing arthroplasty. Several advances have been made in the backing of the tibial components that have not been available long enough to yield long-term comparative follow-up studies. Short-term radiostereographic analysis studies have yielded differing results. Although long-term, high-quality studies are still needed, material advances in biologic fixation surfaces, such as trabecular metal and hydroxyapatite, may offer promising results for young and active patients undergoing total knee arthroplasty when compared with traditional cemented options. Copyright 2013, SLACK Incorporated.
Importance of microscopy in durability studies of solidified and stabilized contaminated soils
Klich, I.; Wilding, L.P.; Drees, L.R.; Landa, E.R.
1999-01-01
Solidification/stabilization (S/S) is recognized by the U.S. EPA as a best demonstrated available technology for the containment of contaminated soils and other hazardous wastes that cannot be destroyed by chemical, thermal, or biological means. Despite the increased use of S/S technologies, little research has been conducted on the weathering and degradation of solidified and stabilized wastes once the treated materials have been buried. Published data to verify the performance and durability of landfilled treated wastes over time are rare. In this preliminary study, optical and electron microscopy (scanning electron microscopy [SEM], transmission electron microscopy [TEM] and electron probe microanalyses [EPMA]) were used to evaluate weathering features associated with metal-bearing contaminated soil that had been solidified and stabilized with Portland cement and subsequently buried on site, stored outdoors aboveground, or achieved in a laboratory warehouse for up to 6 yr. Physical and chemical alteration processes identified include: freeze-thaw cracking, cracking caused by the formation of expansive minerals such as ettringite, carbonation, and the movement of metals from waste aggregates into the cement micromass. Although the extent of degradation after 6 yr is considered slight to moderate, results of this study show that the same environmental concerns that affect the durability of concrete must be considered when evaluating the durability and permanence of the solidification and stabilization of contaminated soils with cement. In addition, such evaluations cannot be based on leaching and chemical analyses alone. The use of all levels of microscopic analyses must be incorporated into studies of the long-term performance of S/S technologies.Solidification/stabilization (S/S) is recognized by the U.S. EPA as a best demonstrated available technology for the containment of contaminated soils and other hazardous wastes that cannot be destroyed by chemical, thermal, or biological means. Despite the increased use of S/S technologies, little research has been conducted on the weathering and degradation of solidified and stabilized wastes once the treated materials have been buried. Published data to verify the performance and durability of landfilled treated wastes over time are rare. In this preliminary study, optical and electron microscopy (scanning electron microscopy [SEM], transmission electron microscopy [TEM] and electron probe microanalyses [EPMA]) were used to evaluate weathering features associated with metal-bearing contaminated soil that had been solidified and stabilized with Portland cement and subsequently buried on site, stored outdoors aboveground, or archived in a laboratory, warehouse for up to 6 yr. Physical and chemical alteration processes identified include: freeze-thaw cracking, cracking caused by the formation of expansive minerals such as ettringite, carbonation, and the movement of metals from waste aggregates into the cement micromass. Although the extent of degradation after 6 yr is considered slight to moderate, results of this study show that the same environmental concerns that affect the durability of concrete must be considered when evaluating the durability and permanence of the solidification and stabilization of contaminated soils with cement. In addition, such evaluations cannot be based on leaching and chemical analyses alone. The use of all levels of microscopic analyses must be incorporated into studies of the long-term performance of S/S technologies.
The effect of curing conditions on the durability of high performance concrete
NASA Astrophysics Data System (ADS)
Bumanis, G.; Bajare, D.
2017-10-01
This study researches compressive strength and durability of the high strength self-compacting concrete (SCC) impacted at early stage by the curing conditions. The mixture compositions of metakaolin containing waste and cenospheres as partial cement replacement (15 wt%) were compared to reference SCC with 100% cement. The specimens prepared in advance were demoulded 24h after casting of the SCC and the specific curing conditions were applied for up to 28 days: standard water curing at 20°C (i); indoor curing at 20°C, RH 60% (ii) and low temperature air curing (2°C) at RH 60% (iii). Results indicate that at early stage (14 days) indoor curing conditions increase compressive strength of the SCC whilst no strength loss has been detected even at a low temperature curing. The further strength gain has been substantially reduced for samples cured indoor and at a low temperature with significant variation observed for long term compressive strength (180 days). The metakaolin containing waste has proved to be an effective partial cement replacement and it has improved strength gain even at a low temperature curing. Meanwhile cenospheres have reduced the SCC strength and with no positive effect on strength observed within the standard term. Freeze-thaw durability and resistance to the chloride penetration have been improved for the SCC cured at low temperature. The SCC with metakaolin containing waste has proved to be the most durable thus demonstrating importance of effective micro filler use.
Mizuno, T; Mizukoshi, T; Uechi, M
2013-02-01
Mitral valve repair under cardiopulmonary bypass was performed in three dogs with clinical signs associated with mitral regurgitation that were not controlled by medication. Mitral valve repair comprised circumferential annuloplasty and chordal replacement with expanded polytetrafluoroethylene. One dog died 2 years after surgery because of severe mitral regurgitation resulting from partial circumferential suture detachment. The others survived for over 5 years, but mild mitral valve stenosis persisted in one. The replaced chordae did not rupture in any dog. Mitral valve repair appears to be an effective treatment for mitral regurgitation in dogs. Chordal replacement with expanded polytetrafluoroethylene is a feasible technique, demonstrating long-term durability in dogs. However, mitral annuloplasty techniques need improvement. © 2012 British Small Animal Veterinary Association.
Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grin, A.; Lstiburek, J.
This guide provides information and recommendations to the following groups: insulation contractors; general contractors; builders; home remodelers; mechanical contractors; and homeowners, as a guide to the work that needs to be done. The order of work completed during home construction and retrofit improvements is important. Health and safety issues must be addressed first and are more important than durability issues. And durability issues are more important than saving energy. Not all techniques can apply to all houses. Special conditions will require special action. Some builders or homeowners will wish to do more than the important but basic retrofit strategies outlinedmore » by this guide. The following are best practice and product recommendations from the interviewed contractors and homebuilders who collectively have a vast amount of experience. Three significant items were discussed with the group which are required to make taped insulating sheathing a simple, long term, and durable drainage plane: 1. Horizontal joints should be limited or eliminated wherever possible; 2. Where a horizontal joint exists use superior materials; 3. Frequent installation inspection and regular trade training are required to maintain proper installation. Section 5 of this measure guideline contains the detailed construction procedure for the three recommended methods to effectively seal the joints in exterior insulating sheathing to create a simple, long term, and durable drainage plane.« less
Long-term efficient organic photovoltaics based on quaternary bulk heterojunctions
NASA Astrophysics Data System (ADS)
Nam, Minwoo; Cha, Minjeong; Lee, Hyun Hwi; Hur, Kahyun; Lee, Kyu-Tae; Yoo, Jaehong; Han, Il Ki; Kwon, S. Joon; Ko, Doo-Hyun
2017-01-01
A major impediment to the commercialization of organic photovoltaics (OPVs) is attaining long-term morphological stability of the bulk heterojunction (BHJ) layer. To secure the stability while pursuing optimized performance, multi-component BHJ-based OPVs have been strategically explored. Here we demonstrate the use of quaternary BHJs (q-BHJs) composed of two conjugated polymer donors and two fullerene acceptors as a novel platform to produce high-efficiency and long-term durable OPVs. A q-BHJ OPV (q-OPV) with an experimentally optimized composition exhibits an enhanced efficiency and extended operational lifetime than does the binary reference OPV. The q-OPV would retain more than 72% of its initial efficiency (for example, 8.42-6.06%) after a 1-year operation at an elevated temperature of 65 °C. This is superior to those of the state-of-the-art BHJ-based OPVs. We attribute the enhanced stability to the significant suppression of domain growth and phase separation between the components via kinetic trapping effect.
[GERD: endoscopic antireflux therapies].
Caca, K
2006-08-02
A couple of minimally-invasive, endoscopic antireflux procedures have been developed during the last years. Beside endoscopic suturing these included injection/implantation technique of biopolymers and application of radiofrequency. Radiofrequency (Stretta) has proved only a very modest effect, while implantation techniques have been abandoned due to lack of long-term efficacy (Gatekeeper) or serious side effects (Enteryx). While first generation endoluminal suturing techniques (EndoCinch, ESD) demonstrated a proof of principle their lack of durability, due to suture loss, led to the development of a potentially durable transmural plication technique (Plicator). In a prospective-randomized, sham-controlled trial the Plicator procedure proved superiority concerning reflux symptoms, medication use and esophageal acid exposure (24-h-pH-metry). While long-term data have to be awaited to draw final conclusions, technical improvements will drive innovation in this field.
Long-term effects of interference on short-term memory performance in the rat.
Missaire, Mégane; Fraize, Nicolas; Joseph, Mickaël Antoine; Hamieh, Al Mahdy; Parmentier, Régis; Marighetto, Aline; Salin, Paul Antoine; Malleret, Gaël
2017-01-01
A distinction has always been made between long-term and short-term memory (also now called working memory, WM). The obvious difference between these two kinds of memory concerns the duration of information storage: information is supposedly transiently stored in WM while it is considered durably consolidated into long-term memory. It is well acknowledged that the content of WM is erased and reset after a short time, to prevent irrelevant information from proactively interfering with newly stored information. In the present study, we used typical WM radial maze tasks to question the brief lifespan of spatial WM content in rodents. Groups of rats were submitted to one of two different WM tasks in a radial maze: a WM task involving the repetitive presentation of a same pair of arms expected to induce a high level of proactive interference (PI) (HIWM task), or a task using a different pair in each trial expected to induce a low level of PI (LIWM task). Performance was effectively lower in the HIWM group than in LIWM in the final trial of each training session, indicative of a "within-session/short-term" PI effect. However, we also observed a different "between-session/long-term" PI effect between the two groups: while performance of LIWM trained rats remained stable over days, the performance of HIWM rats dropped after 10 days of training, and this impairment was visible from the very first trial of the day, hence not attributable to within-session PI. We also showed that a 24 hour-gap across training sessions known to allow consolidation processes to unfold, was a necessary and sufficient condition for the long-term PI effect to occur. These findings suggest that in the HIWM task, WM content was not entirely reset between training sessions and that, in specific conditions, WM content can outlast its purpose by being stored more permanently, generating a long-term deleterious effect of PI. The alternative explanation is that WM content could be transferred and stored more permanently in an intermediary form or memory between WM and long-term memory.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Christians, Jeffrey A.; Schulz, Philip; Tinkham, Jonathan S.
Long-term device stability is the most pressing issue that impedes perovskite solar cell commercialization, given the achieved 22.7% efficiency. The perovskite absorber material itself has been heavily scrutinized for being prone to degradation by water, oxygen and ultraviolet light. To date, most reports characterize device stability in the absence of these extrinsic factors. Here we show that, even under the combined stresses of light (including ultraviolet light), oxygen and moisture, perovskite solar cells can retain 94% of peak efficiency despite 1,000 hours of continuous unencapsulated operation in ambient air conditions (relative humidity of 10-20%). Each interface and contact layer throughoutmore » the device stack plays an important role in the overall stability which, when appropriately modified, yields devices in which both the initial rapid decay (often termed burn-in) and the gradual slower decay are suppressed. This extensively modified device architecture and the understanding developed will lead towards durable long-term device performance.« less
Building a durable response to HIV/AIDS: implications for health systems.
Atun, Rifat; Bataringaya, Jacqueline
2011-08-01
The remarkable rise in investments for HIV control programs in 2003-2010 enabled an unprecedented expansion of access to HIV services in low-income and middle-income countries. By the end of 2010, more than 5.2 million people were receiving antiretroviral therapy (ART), which transformed HIV infection, once a death sentence, into a long-term illness. The rapid expansion in the number of persons receiving ART means that health systems must continue to provide acute life-saving care for those with advanced HIV/AIDS although also providing chronic care services to expanding cohorts of more stable patients who are doing well on ART. This expansion also means a transition from an emergency response to the epidemic, characterized by a public health approach, to a more integrated and durable approach to HIV prevention, care, and treatment services that fosters individualized care for those requiring long-term antiretroviral treatment. Yet most low-income and middle-income countries, which have weak health systems, are poorly prepared to make this transition. In this article, we highlight the challenges health systems face in developing a sustained and durable response to HIV/AIDS. The article analyses the readiness of health systems to combine rapid expansion of ART access with long-term treatment and continuity of care for a growing cohort of patients. We argue that effective management of a transition from an emergency AIDS response to long-term programatic strategies will require a paradigm shift that enables leveraging investments in HIV to build sustainable health systems for managing large cohorts of patients receiving ART although meeting the immediate needs of those who remain without access to HIV treatment and care.
Durability of symmetric-structured metal-supported solid oxide fuel cells
NASA Astrophysics Data System (ADS)
Tucker, Michael C.
2017-11-01
Symmetric-structure metal-supported solid oxide fuel cells (MS-SOFC) with YSZ electrolyte are fabricated with porous YSZ backbone electrodes, stainless steel supports, and infiltrated catalysts on both anode and cathode side. Durability towards aggressive thermal and redox cycling, and long-term operation is assessed. Many sealing material candidates are screened for compatibility with the cell materials and operating conditions, and a commercial sealing glass, GM31107, is selected. LSM/SDCN cells are then subjected to 200 very fast thermal cycles and 20 complete redox cycles, with minimal impact to cell performance. LSM/SDCN and SDCN/SDCN cells are operated for more than 1200 h at 700 °C. The seal and cell hermeticity is maintained, and cell ohmic impedance does not change significantly during operation. Electrode polarization increases during operation, leading to significant degradation of the cell performance. In-operando EIS and post-mortem SEM/EDS analysis suggest that catalyst coarsening and cathode Cr deposition are the dominant degradation modes.
NASA Technical Reports Server (NTRS)
Rojdev, Kristina; O'Rourke, Mary Jane; Hill, Charles; Nutt, Steven; Atwell, William
2011-01-01
Human exploration of space beyond low Earth orbit (LEO) requires a safe living and working environment for crew. Composite materials are one type of material being investigated by NASA as a multi-functional structural approach to habitats for long-term use in space or on planetary surfaces with limited magnetic fields and atmosphere. These materials provide high strength with the potential for decreased weight and increased radiation protection of crew and electronics when compared with conventional aluminum structures. However, these materials have not been evaluated in a harsh radiation environment, as would be experienced outside of LEO or on a planetary surface. Thus, NASA has been investigating the durability of select composite materials in a long-term radiation environment. Previously, NASA exposed composite samples to a simulated, accelerated 30-year radiation treatment and tensile stresses similar to those of a habitat pressure vessel. The results showed evidence of potential surface oxidation and enhanced cross-linking of the matrix. As a follow-on study, we performed the same accelerated exposure alongside an exposure with a decreased dose rate. The slower dose ]rate is comparable to a realistic scenario, although still accelerated. Strain measurements were collected during exposure and showed that with a fastdose rate, the strain decreased with time, but with a slow ]dose rate, the strain increased with time. After the radiation exposures, samples were characterized via tensile tests, flexure tests, Fourier Transform Infrared Spectroscopy (FTIR), and Differential Scanning Calorimetry (DSC). The results of these tests will be discussed.
Moutsopoulou, Karolina; Waszak, Florian
2013-05-01
It has been shown that in associative learning it is possible to disentangle the effects caused on behaviour by the associations between a stimulus and a classification (S-C) and the associations between a stimulus and the action performed towards it (S-A). Such evidence has been provided using ex-Gaussian distribution analysis to show that different parameters of the reaction time distribution reflect the different processes. Here, using this method, we investigate another difference between these two types of associations: What is the relative durability of these associations across time? Using a task-switching paradigm and by manipulating the lag between the point of the creation of the associations and the test phase, we show that S-A associations have stronger effects on behaviour when the lag between the two repetitions of a stimulus is short. However, classification learning affects behaviour not only in short-term lags but also (and equally so) when the lag between prime and probe is long and the same stimuli are repeatedly presented within a different classification task, demonstrating a remarkable durability of S-C associations.
NASA Astrophysics Data System (ADS)
Schmitt, Michael P.; Schreiber, Jeremy M.; Rai, Amarendra K.; Eden, Timothy J.; Wolfe, Douglas E.
2017-08-01
Rare-earth pyrochlores, RE2Zr2O7, have been identified as potential thermal barrier coating (TBC) materials due to their attractive thermal properties and CMAS resistance. However, they possess a low fracture toughness which results in poor erosion durability/foreign object damage resistance. This research focuses on the development of tailored composite air plasma spray (APS) TBC design architectures utilizing a t' Low-k secondary toughening phase (ZrO2-2Y2O3-1Gd2O3-1Yb2O3; mol.%) to enhance the erosion durability of a hyper-stoichiometric pyrochlore, NZO (ZrO2-25Nd2O3-5Y2O3-5Yb2O3; mol.%). In this study, composite coatings have been deposited with 30, 50, and 70% (wt.%) t' Low-k toughening phase in a horizontally aligned lamellar morphology which enhances the toughening response of the coating. The coatings were characterized via SEM and XRD and were tested for erosion durability before and after isothermal heat treatment at 1100 °C. Analysis with mixing laws indicated improved erosion performance; however, a lack of long-term thermal stability was shown via isothermal heat treatments at 1316 °C. An impact stress analysis was performed using finite element analysis of a coating cross section, representing the first microstructurally realistic study of mechanical properties of TBCs with the results correlating well with observed behavior.
2012-01-30
CFRP LAMINATES FOR MARINE USE Sa. CONTRACT NUMBER 5b. GRANT NUMBER N00014-06-1-1139 Sc. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Miyano, Yasushi...prediction of CFRP laminates proposed and confirmed experimentally in the previous ONR project of Grant # N000140110949 was verified theoretically and refined...DURABILITY OF CFRP LAMINATES FOR MARINE USE Principal Investigator Yasushi Miyano Co-principal Investigator Isao Kimpara Materials System
Self-etching adhesives: review of adhesion to tooth structure part II.
Strydom, C
2005-02-01
Self-etching adhesives are steadily increasing in popularity among dental practitioners with their easy handling technique and their promise of no post-op sensitivity. As with any new bonding material, in vitro and in vivo investigations are required to assess the clinical efficacy of these systems. The current literature was reviewed to provide information on these systems, including the influence of their acidity and permeability on the quality of the bond, the role of water in long-term degradation of the bond in in vivo and in vitro studies, and the clinical efficacy of the self-etching adhesives in clinical research studies. Published abstracts, reviews, laboratory reports and clinical research papers in the dental literature. Very little information is available on self-etching systems pertaining to the long-term in vitro and in vivo durability of their bond and their medium- to long-term clinical outcome. Although post-op sensitivity seems to be something of the past, short-term clinical studies show that some self-etching adhesives do not perform as well as total-etch systems.
NASA Astrophysics Data System (ADS)
Carmona-Quiroga, P. M.; Martínez-Ramírez, S.; Viles, H. A.
2018-03-01
This study aimed to test the performance under long-term working conditions of a commercial self-cleaning coating, a water-based TiO2 sol, on three building materials important in recent and older European heritage; Portland limestone, Woodkirk sandstone and concrete. First, the compatibility of the coating (effect on petrophysical properties) with the substrates was demonstrated by examining aesthetic properties and water vapour permeability of the building materials and secondly, the self-cleaning ability of the TiO2 nanoparticles in degrading artificial stain (rhodamine B) under UV light was evaluated. Finally, the durability (lasting performance) of photocatalytic activity was assessed during one year of outdoor exposure trial and 2000 h of accelerated ageing in a chamber with UV radiation and condensation cycles. Results showed that photocatalytic activity was unaltered on concrete, whereas on sandstone, particularly after artificial ageing, it was reduced due to the removal of nanoparticles from the surface. On limestone, a decrease of TiO2 content was observed but photodegradation efficiency (ability to perform as self-cleaner) seemed not to be affected.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moreno, Arnaldo
The Network of Excellence 'Knowledge-based Multicomponent Materials for Durable and Safe Performance' (KMM-NoE) consists of 36 institutional partners from 10 countries representing leading European research institutes and university departments (25), small and medium enterprises, SMEs (5) and large industry (7) in the field of knowledge-based multicomponent materials (KMM), more specifically in intermetallics, metal-ceramic composites, functionally graded materials and thin layers. The main goal of the KMM-NoE (currently funded by the European Commission) is to mobilise and concentrate the fragmented scientific potential in the KMM field to create a durable and efficient organism capable of developing leading-edge research while spreading themore » accumulated knowledge outside the Network and enhancing the technological skills of the related industries. The long-term strategic goal of the KMM-NoE is to establish a self-supporting pan-European institution in the field of knowledge-based multicomponent materials--KMM Virtual Institute (KMM-VIN). It will combine industry oriented research with educational and training activities. The KMM Virtual Institute will be founded on three main pillars: KMM European Competence Centre, KMM Integrated Post-Graduate School, KMM Mobility Programme. The KMM-NoE is coordinated by the Institute of Fundamental Technological Research (IPPT) of the Polish Academy of Sciences, Warsaw, Poland.« less
Song, Howard K; Preiss, Liliana R; Maslen, Cheryl L; Kroner, Barbara; Devereux, Richard B; Roman, Mary J; Holmes, Kathryn W; Tolunay, H Eser; Desvigne-Nickens, Patrice; Asch, Federico M; Milewski, Rita K; Bavaria, Joseph; LeMaire, Scott A
2014-05-01
The long-term outcomes of aortic valve-sparing (AVS) root replacement in Marfan syndrome (MFS) patients remain uncertain. The study aim was to determine the utilization and outcomes of AVS root replacement in MFS patients enrolled in the Registry of Genetically Triggered Thoracic Aortic Aneurysms and Cardiovascular Conditions (GenTAC). At the time of this analysis, 788 patients with MFS were enrolled in the GenTAC Registry, of whom 288 had undergone aortic root replacement. Patients who had undergone AVS procedures were compared to those who had undergone aortic valve replacement (AVR). AVS root replacement was performed in 43.5% of MFS patients, and the frequency of AVS was increased over the past five years. AVS patients were younger at the time of surgery (31.0 versus 36.3 years, p = 0.006) and more likely to have had elective rather than emergency surgery compared to AVR patients, in whom aortic valve dysfunction and aortic dissection was the more likely primary indication for surgery. After a mean follow up of 6.2 +/- 3.6 years, none of the 87 AVS patients had required reoperation; in contrast, after a mean follow up of 10.5 +/- 7.6 years, 11.5% of AVR patients required aortic root reoperation. Aortic valve function has been durable, with 95.8% of AVS patients having aortic insufficiency that was graded as mild or less. AVS root replacement is performed commonly among the MFS population, and the durability of the aortic repair and aortic valve function have been excellent to date. These results justify a continued use of the procedure in an elective setting. The GenTAC Registry will be a useful resource to assess the long-term durability of AVS root replacement in the future.
Ensuring Longevity: Ancient Glasses Help Predict Durability of Vitrified Nuclear Waste
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weaver, Jamie L.; McCloy, John S.; Ryan, Joseph V.
How does glass alter with time? For the last hundred years this has been an important question to the fields of object conservation and archeology to ensure the preservation of glass artifacts. This same question is part of the development and assessment of durable glass waste forms for the immobilization of nuclear wastes. Researchers have developed experiments ranging from simple to highly sophisticated to answer this question, and, as a result, have gained significant insight into the mechanisms that drive glass alteration. However, the gathered data have been predominately applicable to only short-term alteration times, i.e. over the course ofmore » decades. What has remained elusive is the long-term mechanisms of glass alteration[1]. These mechanisms are of particular interest to the international nuclear waste glass community as they strive to ensure that vitrified products will be durable for thousands to tens of thousands of years. For the last thirty years this community has been working to fill this research gap by partnering with archeologists, museum curators, and geologists to identify hundred to million-year old glass analogues that have altered in environments representative of those expected at potential nuclear waste disposal sites. The process of identifying a waste glass relevant analogue is challenging as it requires scientists to relate data collected from short-term laboratory experiments to observations made from long-term analogues and extensive geochemical modeling.« less
Long-Term Viscoelastic Response of E-glass/Bismaleimide Composite in Seawater Environment
NASA Astrophysics Data System (ADS)
Yian, Zhao; Zhiying, Wang; Keey, Seah Leong; Boay, Chai Gin
2015-12-01
The effect of seawater absorption on the long-term viscoelastic response of E-glass/BMI composite is presented in this paper. The diffusion of seawater into the composite shows a two-stage behavior, dominated by Fickian diffusion initially and followed by polymeric relaxation. The Glass transition temperature (Tg) of the composite with seawater absorption is considerably lowered due to the plasticization effect. However the effect of water absorption at 50 °C is found to be reversible after drying process. The time-temperature superposition (TTS) was performed based on the results of Dynamic Mechanical Analysis to construct the master curve of storage modulus. The shift factors exhibit Arrhenius behavior when temperature is well below Tg and Vogel-Fulcher-Tammann (VFT) like behavior when temperature gets close to glass transition region. As a result, a semi-empirical formulation is proposed to account for the seawater absorption effect in predicting long-term viscoelastic response of BMI composites based on temperature dependent storage modulus and TTS. The predicted master curves show that the degradation of storage modulus accelerates with both seawater exposure and increasing temperature. The proposed formulation can be applied to predict the long-term durability of any thermorheologically simple composite materials in seawater environment.
Long-term effects of interference on short-term memory performance in the rat
Missaire, Mégane; Fraize, Nicolas; Joseph, Mickaël Antoine; Hamieh, Al Mahdy; Parmentier, Régis; Marighetto, Aline; Salin, Paul Antoine; Malleret, Gaël
2017-01-01
A distinction has always been made between long-term and short-term memory (also now called working memory, WM). The obvious difference between these two kinds of memory concerns the duration of information storage: information is supposedly transiently stored in WM while it is considered durably consolidated into long-term memory. It is well acknowledged that the content of WM is erased and reset after a short time, to prevent irrelevant information from proactively interfering with newly stored information. In the present study, we used typical WM radial maze tasks to question the brief lifespan of spatial WM content in rodents. Groups of rats were submitted to one of two different WM tasks in a radial maze: a WM task involving the repetitive presentation of a same pair of arms expected to induce a high level of proactive interference (PI) (HIWM task), or a task using a different pair in each trial expected to induce a low level of PI (LIWM task). Performance was effectively lower in the HIWM group than in LIWM in the final trial of each training session, indicative of a “within-session/short-term” PI effect. However, we also observed a different “between-session/long-term” PI effect between the two groups: while performance of LIWM trained rats remained stable over days, the performance of HIWM rats dropped after 10 days of training, and this impairment was visible from the very first trial of the day, hence not attributable to within-session PI. We also showed that a 24 hour-gap across training sessions known to allow consolidation processes to unfold, was a necessary and sufficient condition for the long-term PI effect to occur. These findings suggest that in the HIWM task, WM content was not entirely reset between training sessions and that, in specific conditions, WM content can outlast its purpose by being stored more permanently, generating a long-term deleterious effect of PI. The alternative explanation is that WM content could be transferred and stored more permanently in an intermediary form or memory between WM and long-term memory. PMID:28288205
A rule-based expert system applied to moisture durability of building envelopes
Boudreaux, Philip R.; Pallin, Simon B.; Accawi, Gina K.; ...
2018-01-09
The moisture durability of an envelope component such as a wall or roof is difficult to predict. Moisture durability depends on all the construction materials used, as well as the climate, orientation, air tightness, and indoor conditions. Modern building codes require more insulation and tighter construction but provide little guidance about how to ensure these energy-efficient assemblies remain moisture durable. Furthermore, as new products and materials are introduced, builders are increasingly uncertain about the long-term durability of their building envelope designs. Oak Ridge National Laboratory and the US Department of Energy’s Building America Program are applying a rule-based expert systemmore » methodology in a web tool to help designers determine whether a given wall design is likely to be moisture durable and provide expert guidance on moisture risk management specific to a wall design and climate. Finally, the expert system is populated with knowledge from both expert judgment and probabilistic hygrothermal simulation results.« less
A rule-based expert system applied to moisture durability of building envelopes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boudreaux, Philip R.; Pallin, Simon B.; Accawi, Gina K.
The moisture durability of an envelope component such as a wall or roof is difficult to predict. Moisture durability depends on all the construction materials used, as well as the climate, orientation, air tightness, and indoor conditions. Modern building codes require more insulation and tighter construction but provide little guidance about how to ensure these energy-efficient assemblies remain moisture durable. Furthermore, as new products and materials are introduced, builders are increasingly uncertain about the long-term durability of their building envelope designs. Oak Ridge National Laboratory and the US Department of Energy’s Building America Program are applying a rule-based expert systemmore » methodology in a web tool to help designers determine whether a given wall design is likely to be moisture durable and provide expert guidance on moisture risk management specific to a wall design and climate. Finally, the expert system is populated with knowledge from both expert judgment and probabilistic hygrothermal simulation results.« less
Recent advances in the mechanical durability of superhydrophobic materials.
Milionis, Athanasios; Loth, Eric; Bayer, Ilker S
2016-03-01
Large majority of superhydrophobic surfaces have very limited mechanical wear robustness and long-term durability. This problem has restricted their utilization in commercial or industrial applications and resulted in extensive research efforts on improving resistance against various types of wear damage. In this review, advances and developments since 2011 in this field will be covered. As such, we summarize progress on fabrication, design and understanding of mechanically durable superhydrophobic surfaces. This includes an overview of recently published diagnostic techniques for probing and demonstrating tribo-mechanical durability against wear and abrasion as well as other effects such as solid/liquid spray or jet impact and underwater resistance. The review is organized in terms of various types of mechanical wear ranging from substrate adhesion, tangential surface abrasion, and dynamic impact to ultrasonic processing underwater. In each of these categories, we highlight the most successful approaches to produce robust surfaces that can maintain their non-wetting state after the wear or abrasive action. Finally, various recommendations for improvement of mechanical wear durability and its quantitative evaluation are discussed along with potential future directions towards more systematic testing methods which will also be acceptable for industry. Copyright © 2015 Elsevier B.V. All rights reserved.
Textile for heart valve prostheses: fabric long-term durability testing.
Heim, Frederic; Durand, Bernard; Chakfe, Nabil
2010-01-01
The rapid developments and success in percutaneous vascular surgery over the last two decades with the now common stent grafts implantation, make the noninvasive surgery technique today attractive even for heart valve replacement. Less traumatic for the patient and also less time consuming, percutaneous heart valve replacement is however at its beginning and restricted to end of life patients. The noninvasive procedure expects from the heart valve prosthesis material to be resistant and adapted to folding requirements of the implantation process (catheter). Polyester fabric could be a suited material for heart valve implanted percutaneously. Highly flexible and resistant, polyester fabric proved to be well adapted to the dynamic behavior of a valve and polyester (Dacron) is also widely used for vascular grafts implantation and shows good biocompatibility and durability. However, today there's no data available on long-term durability of fabric used as heart valve material. The purpose of this work is to study the long term behavior of a microdenier polyester fabric construction under combined in vitro flexure and tension fatigue stress. In the novel in vitro testing technique presented, a fabric specimen was subjected to combined flexural and tensile fatigue generated by fluid flow under physiological pressure conditions. The results obtained show how flexural properties change with fatigue time, which reflects directly on the suitability of a fabric in such devices. It was also observed that these fabric structural changes directly influence the in vitro behavior of the textile heart valve prosthesis. (c) 2009 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This guide provides information and recommendations to the following groups: Insulation contractors, General contractors, Builders, Home remodelers, Mechanical contractors, and Homeowners as a guide to the work that needs to be done. The order of work completed during home construction and retrofit improvements is important. Health and safety issues must be addressed first and are more important than durability issues. And durability issues are more important than saving energy. Not all techniques can apply to all houses. Special conditions will require special action. Some builders or homeowners will wish to do more than the important but basic retrofit strategies outlinedmore » by this guide. The following are best practice and product recommendations from the interviewed contractors and home builders who collectively have a vast amount of experience. Three significant items were discussed with the group which are required to make taped insulating sheathing a simple, long term, and durable drainage plane: 4. Horizontal joints should be limited or eliminated wherever possible 5. Where a horizontal joint exists use superior materials 6. Frequent installation inspection and regular trade training are required to maintain proper installation Section 5 of this measure guideline contains the detailed construction procedure for the three recommended methods to effectively seal the joints in exterior insulating sheathing to create a simple, long term, and durable drainage plane.« less
Madhu, Rajesh; Veeramani, Vediyappan; Chen, Shen-Ming; Manikandan, Arumugam; Lo, An-Ya; Chueh, Yu-Lun
2015-07-29
Herein, we report the preparation of Pongam seed shells-derived activated carbon and cobalt oxide (∼2-10 nm) nanocomposite (PSAC/Co3O4) by using a general and facile synthesis strategy. The as-synthesized PSAC/Co3O4 samples were characterized by a variety of physicochemical techniques. The PSAC/Co3O4-modified electrode is employed in two different applications such as high performance nonenzymatic glucose sensor and supercapacitor. Remarkably, the fabricated glucose sensor is exhibited an ultrahigh sensitivity of 34.2 mA mM(-1) cm(-2) with a very low detection limit (21 nM) and long-term durability. The PSAC/Co3O4 modified stainless steel electrode possesses an appreciable specific capacitance and remarkable long-term cycling stability. The obtained results suggest the as-synthesized PSAC/Co3O4 is more suitable for the nonenzymatic glucose sensor and supercapacitor applications outperforming the related carbon based modified electrodes, rendering practical industrial applications.
Ethanol-diesel fuel blends -- a review.
Hansen, Alan C; Zhang, Qin; Lyne, Peter W L
2005-02-01
Ethanol is an attractive alternative fuel because it is a renewable bio-based resource and it is oxygenated, thereby providing the potential to reduce particulate emissions in compression-ignition engines. In this review the properties and specifications of ethanol blended with diesel fuel are discussed. Special emphasis is placed on the factors critical to the potential commercial use of these blends. These factors include blend properties such as stability, viscosity and lubricity, safety and materials compatibility. The effect of the fuel on engine performance, durability and emissions is also considered. The formulation of additives to correct certain key properties and maintain blend stability is suggested as a critical factor in ensuring fuel compatibility with engines. However, maintaining vehicle safety with these blends may entail fuel tank modifications. Further work is required in specifying acceptable fuel characteristics, confirming the long-term effects on engine durability, and ensuring safety in handling and storing ethanol-diesel blends.
Atomic oxygen effects on materials
NASA Technical Reports Server (NTRS)
Banks, Bruce A.; Rutledge, Sharon K.; Brady, Joyce A.; Merrow, James E.
1989-01-01
Understanding of the basic processes of atomic oxygen interaction is currently at a very elementary level. However, measurement of erosion yields, surface morphology, and optical properties for low fluences have brought about much progress in the past decade. Understanding the mechanisms and those factors that are important for proper simulation of low Earth orbit is at a much lower level of understanding. The ability to use laboratory simulations with confidence to quantifiably address the functional performance and durability of materials in low Earth orbit will be necessary to assure long-term survivability to the natural space environment.
NASA Technical Reports Server (NTRS)
Kaufman, A.; Olson, B.; Pudick, S.; Wang, C. L.; Werth, J.; Whelan, J. A.
1986-01-01
The testing of two 25-cell stacks of the 13 inch x 23 inch cell size (about 4kW) was carried out for 7000 and 8400 hours, respectively. A 25kW stack containing 175 cells of the same size and based on the same technology was constructed and is on test. A third 4kW stack, which will contain 24 cells, will comprise several new technology features; these will be assesed for performance and durability in long-term testing.
Strength and reliability analysis of metal-composite overwrapped pressure vessel
NASA Astrophysics Data System (ADS)
Burov, A. E.; Lepikhin, A. M.; Moskvichev, V. V.
2017-12-01
Metal-composite overwrapped pressure vessels (MCOPV) have found a wide application in aerospace and aeronautical industries. Such vessels should combine impermeability and high weight efficiency with enhanced long-term safety and durability. To meet these requirements, theoretical and experimental studies on the mechanics of deformation and failure of MCOPV are required. In the paper, the analysis on strength, lifetime and reliability of MCOPV is presented. A high performance of the MCOPV is justified by comparing the calculation results with experiment data obtained on full-scale samples.
Toklu, Bora; Amoroso, Nicholas; Fusaro, Mario; Kumar, Sunil; Hannan, Edward L; Faxon, David P; Feit, Frederick
2013-01-01
Objective To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. Design Mixed treatment comparison meta-analysis of 258 544 patient years of follow-up from randomized trials. Data sources and study selection PubMed, Embase, and Central were searched for randomized trials comparing any of the Food and Drug Administration approved durable polymer drug eluting stents (sirolimus eluting, paclitaxel eluting, cobalt chromium everolimus eluting, platinum chromium everolimus eluting, zotarolimus eluting-Endeavor, and zotarolimus eluting-Resolute) or biodegradable polymer drug eluting stents, with each other or against bare metal stents. Outcomes Long term efficacy (target vessel revascularization, target lesion revascularization) and safety (death, myocardial infarction, stent thrombosis). Landmark analysis at more than one year was evaluated to assess the potential late benefit of biodegradable polymer drug eluting stents. Results From 126 randomized trials and 258 544 patient years of follow-up, for long term efficacy (target vessel revascularization), biodegradable polymer drug eluting stents were superior to paclitaxel eluting stents (rate ratio 0.66, 95% credibility interval 0.57 to 0.78) and zotarolimus eluting stent-Endeavor (0.69, 0.56 to 0.84) but not to newer generation durable polymer drug eluting stents (for example: 1.03, 0.89 to 1.21 versus cobalt chromium everolimus eluting stents). Similarly, biodegradable polymer drug eluting stents were superior to paclitaxel eluting stents (rate ratio 0.61, 0.37 to 0.89) but inferior to cobalt chromium everolimus eluting stents (2.04, 1.27 to 3.35) for long term safety (definite stent thrombosis). In the landmark analysis after one year, biodegradable polymer drug eluting stents were superior to sirolimus eluting stents for definite stent thrombosis (rate ratio 0.29, 0.10 to 0.82) but were associated with increased mortality compared with cobalt chromium everolimus eluting stents (1.52, 1.02 to 2.22). Overall, among all stent types, the newer generation durable polymer drug eluting stents (zotarolimus eluting stent-Resolute, cobalt chromium everolimus eluting stents, and platinum chromium everolimus eluting stents) were the most efficacious (lowest target vessel revascularization rate) stents, and cobalt chromium everolimus eluting stents were the safest with significant reductions in definite stent thrombosis (rate ratio 0.35, 0.21 to 0.53), myocardial infarction (0.65, 0.55 to 0.75), and death (0.72, 0.58 to 0.90) compared with bare metal stents. Conclusions Biodegradable polymer drug eluting stents are superior to first generation durable polymer drug eluting stents but not to newer generation durable polymer stents in reducing target vessel revascularization. Newer generation durable polymer stents, and especially cobalt chromium everolimus eluting stents, have the best combination of efficacy and safety. The utility of biodegradable polymer stents in the context of excellent clinical outcomes with newer generation durable polymer stents needs to be proven. PMID:24212107
CONTECH(R) A-2000 polyvinyl chloride (PVC) plastic pipe.
DOT National Transportation Integrated Search
2015-03-01
Determine the effectiveness and long-term durability of the Contech A-2000 PVC pipe : in an irrigation application. This type of pipe may prove to be a viable alternative to : reinforced concrete pipe (RCP).
NASA Astrophysics Data System (ADS)
Salah, Faisal Mohammed; Jaya, Ramadhansyah Putra; Mohamed, Azman; Hassan, Norhidayah Abdul; Rosni, Nurul Najihah Mad; Mohamed, Abdullahi Ali; Agussabti
2017-12-01
The influence of styrene butadiene rubber (SBR) on asphaltic concrete properties at different aging conditions was presented in this study. These aging conditions were named as un-aged, short-term, and long-term aging. The conventional asphalt binder of penetration grade 60/70 was used in this work. Four different levels of SBR addition were employed (i.e., 0 %, 1 %, 3 %, and 5 % by binder weight). Asphalt concrete mixes were prepared at selected optimum asphalt content (5 %). The performance was evaluated based on Marshall Stability, resilient modulus, and dynamic creep tests. Results indicated the improving stability and permanent deformation characteristics that the mixes modified with SBR polymer have under aging conditions. The result also showed that the stability, resilient modulus, and dynamic creep tests have the highest rates compared to the short-term aging and un-aged samples. Thus, the use of 5 % SBR can produce more durable asphalt concrete mixtures with better serviceability.
Assessment of the long-term durability of concrete in radioactive waste repositories
DOE Office of Scientific and Technical Information (OSTI.GOV)
Atkinson, A.; Goult, D.J.; Hearne, J.A.
1986-01-01
A preliminary assessment of the long-term durability of concrete in a repository sited in clay is presented. The assessment is based on recorded experience of concrete structures and both field and laboratory studies. It is also supported by results of the examination of a concrete sample which had been buried in clay for 43 years. The engineering lifetime of a 1 m thick reinforced concrete slab, with one face in contact with clay, and the way in which pH in the repository as a whole is likely to vary with time have both been estimated from available data. The estimatesmore » indicate that engineering lifetimes of about 10/sup 3/ years are expected (providing that sulfate resisting cement is used) and that pH is likely to remain above 10.5 for about 10/sup 6/ years.« less
Effects of commercial aircraft operating environment on composite materials
NASA Technical Reports Server (NTRS)
Chapman, A. J.; Hoffman, D. J.; Hodges, W. T.
1980-01-01
Long term effects of commercial aircraft operating environment on the properties and durability of composite materials are being systematically explored. Composite specimens configured for various mechanical property tests are exposed to environmental conditions on aircraft in scheduled airline service, on racks at major airports, and to controlled environmental conditions in the laboratory. Results of tests following these exposures will identify critical parameters affecting composite durability, and correlation of the data will aid in developing methods for predicting durability. Interim results of these studies show that mass change of composite specimens on commercial aircraft depends upon the regional climate and season, and that mass loss from composite surfaces due to ultraviolet radiation can be largely prevented by aircraft paint.
Precast concrete pavement - systems and performance review
NASA Astrophysics Data System (ADS)
Novak, Josef; Kohoutková, Alena; Křístek, Vladimír; Vodička, Jan
2017-09-01
Long-term traffic restrictions belong to the key disadvantages of conventional cast-in-plane concrete pavements which have been used for technical structures such as roads, parking place and airfield pavements. As a consequence, the pressure is put on the development of such systems which have short construction time, low production costs, long-term durability, low maintenance requirements etc.. The paper presents the first step in the development of an entirely new precast concrete pavement (PCP) system applicable to airfield and highway pavements. The main objective of the review of PCP systems is to acquire a better understanding of the current systems and design methods used for transport infrastructure. There is lack of information on using PCP systems for the construction of entirely new pavements. To most extensive experience is dated back to the 20th century when hexagonal slab panels and system PAG were used in the Soviet Union for the military airfields. Since cast-in-situ pavements became more common, the systems based on precast concrete panels have been mainly utilized for the removal of damaged sections of existing structures including roads, highways etc.. Namely, it concerns Fort Miller Super Slab system, Michigan system, Uretek Stitch system and Kwik system. The presented review indicates several issues associated with the listed PCP systems and their applications to the repair and rehabilitation of existing structures. Among others, the type of manufacturing technology, particularly the position of slots for dowel bars, affects the durability and performance of the systems. Gathered information serve for the development of a new system for airfield and highway pavement construction.
Arai, Yoichi; Takei, Mineo; Nonomura, Katsuya; Baba, Shiro; Habuchi, Tomonori; Matsuda, Tadashi; Takahashi, Satoru; Igawa, Mikio; Kaiho, Yasuhiro; Nakagawa, Haruo
2009-01-01
Although the artificial urinary sphincter (AUS) is one of the most effective surgical treatments for severe urinary incontinence, little is known about its use in Japan. A nationwide survey was done to determine contemporary trends in AUS use and its long-term durability. Data on AUS units sold in Japan were provided directly by Takai Hospital Supply Co., Ltd., Tokyo, Japan, and a survey form was sent to all 44 institutes where AUS implantation had been carried out. The survey included various demographic and preoperative variables, surgical variables, and postoperative outcomes. Between 1994 and 2007, a total of 100 AUS devices had been provided in Japan. Of the 44 institutes, 24 responded to the survey, and a total of 64 patients were enrolled in the study. Post-urological surgery incontinence accounted for 81.3% of the indications. During the mean follow-up of 50 months, mechanical failure occurred in four (6.2%), and the device was removed in 13 (20.3%) due to infection (14.0%), erosion (4.7%), or urination difficulty (1.5%). Of the 58 patients evaluated, 91.4% reported social continence. Five- and 10-year failure-free rates were 74.8% and 70.1%, respectively. On multivariate analysis, operative time was an independent predictor of treatment failure (P = 0.0334). Considering recent trends in prostate surgery, the AUS may be significantly underused in Japan. Although excellent long-term durability has been achieved, a learning effect appears to be evident. The Japanese urological community needs to provide appropriate patients with this treatment option.
Long-term stormwater quantity and quality performance of permeable pavement systems.
Brattebo, Benjamin O; Booth, Derek B
2003-11-01
This study examined the long-term effectiveness of permeable pavement as an alternative to traditional impervious asphalt pavement in a parking area. Four commercially available permeable pavement systems were evaluated after 6 years of daily parking usage for structural durability, ability to infiltrate precipitation, and impacts on infiltrate water quality. All four permeable pavement systems showed no major signs of wear. Virtually all rainwater infiltrated through the permeable pavements, with almost no surface runoff. The infiltrated water had significantly lower levels of copper and zinc than the direct surface runoff from the asphalt area. Motor oil was detected in 89% of samples from the asphalt runoff but not in any water sample infiltrated through the permeable pavement. Neither lead nor diesel fuel were detected in any sample. Infiltrate measured 5 years earlier displayed significantly higher concentrations of zinc and significantly lower concentrations of copper and lead.
Eltchaninoff, Hélène; Durand, Eric; Avinée, Guillaume; Tron, Christophe; Litzler, Pierre-Yves; Bauer, Fabrice; Dacher, Jean-Nicolas; Werhlin, Camille; Bouhzam, Najime; Bettinger, Nicolas; Candolfi, Pascal; Cribier, Alain
2018-03-30
Durability of transcatheter aortic bioprosthetic valves remains a major issue. Standardised definitions of deterioration and failure of bioprosthetic valves have recently been proposed. The aim of this study was to assess structural transcatheter valve deterioration (SVD) and bioprosthetic valve failure (BVF) using these new definitions. All TAVI patients implanted up to September 2012 with a minimal theoretical five-year follow-up were included. Systematic clinical and echocardiographic follow-up was performed annually. New standardised definitions were used to assess durability of transcatheter aortic bioprosthetic valves. From 2002 to 2012, 378 patients were included. Mean age and logistic EuroSCORE were 83.3±6.8 years and 22.8±13.1%. Thirty-day mortality was 13.2%. Nine patients had SVD including two severe forms and two patients had definite late BVF. The incidence of SVD and BVF at eight years was 3.2% (95% CI: 1.45-6.11) and 0.58% (95% CI: 0.15-2.75), respectively. Even though limited by the poor survival of the very high-risk/compassionate early population, our data do not demonstrate any alarm concerning transcatheter aortic valve durability. Careful prospective assessment in younger and lower-risk patients and comparison with surgical bioprosthetic valves are required for further assessment of the long-term durability of transcatheter valves.
Shui, Jianglan; Wang, Min; Du, Feng; Dai, Liming
2015-01-01
The availability of low-cost, efficient, and durable catalysts for oxygen reduction reaction (ORR) is a prerequisite for commercialization of the fuel cell technology. Along with intensive research efforts of more than half a century in developing nonprecious metal catalysts (NPMCs) to replace the expensive and scarce platinum-based catalysts, a new class of carbon-based, low-cost, metal-free ORR catalysts was demonstrated to show superior ORR performance to commercial platinum catalysts, particularly in alkaline electrolytes. However, their large-scale practical application in more popular acidic polymer electrolyte membrane (PEM) fuel cells remained elusive because they are often found to be less effective in acidic electrolytes, and no attempt has been made for a single PEM cell test. We demonstrated that rationally designed, metal-free, nitrogen-doped carbon nanotubes and their graphene composites exhibited significantly better long-term operational stabilities and comparable gravimetric power densities with respect to the best NPMC in acidic PEM cells. This work represents a major breakthrough in removing the bottlenecks to translate low-cost, metal-free, carbon-based ORR catalysts to commercial reality, and opens avenues for clean energy generation from affordable and durable fuel cells. PMID:26601132
Shui, Jianglan; Wang, Min; Du, Feng; Dai, Liming
2015-02-01
The availability of low-cost, efficient, and durable catalysts for oxygen reduction reaction (ORR) is a prerequisite for commercialization of the fuel cell technology. Along with intensive research efforts of more than half a century in developing nonprecious metal catalysts (NPMCs) to replace the expensive and scarce platinum-based catalysts, a new class of carbon-based, low-cost, metal-free ORR catalysts was demonstrated to show superior ORR performance to commercial platinum catalysts, particularly in alkaline electrolytes. However, their large-scale practical application in more popular acidic polymer electrolyte membrane (PEM) fuel cells remained elusive because they are often found to be less effective in acidic electrolytes, and no attempt has been made for a single PEM cell test. We demonstrated that rationally designed, metal-free, nitrogen-doped carbon nanotubes and their graphene composites exhibited significantly better long-term operational stabilities and comparable gravimetric power densities with respect to the best NPMC in acidic PEM cells. This work represents a major breakthrough in removing the bottlenecks to translate low-cost, metal-free, carbon-based ORR catalysts to commercial reality, and opens avenues for clean energy generation from affordable and durable fuel cells.
NASA Astrophysics Data System (ADS)
Jeong, Yeon Hun; Oh, Kyeongmin; Ahn, Sungha; Kim, Na Young; Byeon, Ayeong; Park, Hee-Young; Lee, So Young; Park, Hyun S.; Yoo, Sung Jong; Jang, Jong Hyun; Kim, Hyoung-Juhn; Ju, Hyunchul; Kim, Jin Young
2017-09-01
Precise monitoring of electrolyte leaching in high-temperature polymer electrolyte membrane fuel cell (HT-PEMFC) devices during lifetime tests is helpful in making a diagnosis of their quality changes and analyzing their electrochemical performance degradation. Here, we investigate electrolyte leaching in the performance degradation of phosphoric acid (PA)-doped polybenzimidazole (PBI) membrane-based HT-PEMFCs. We first perform quantitative analyses to measure PA leakage during cell operation by spectrophotometric means, and a higher PA leakage rate is detected when the current density is elevated in the cell. Second, long-term degradation tests under various current densities of the cells and electrochemical impedance spectroscopy (EIS) analysis are performed to examine the influence of PA loss on the membrane and electrodes during cell performance degradation. The combined results indicate that PA leakage affect cell performance durability, mostly due to an increase in charge transfer resistance and a decrease in the electrochemical surface area (ECSA) of the electrodes. Additionally, a three-dimensional (3-D) HT-PEMFC model is applied to a real-scale experimental cell, and is successfully validated against the polarization curves measured during various long-term experiments. The simulation results highlight that the PA loss from the cathode catalyst layer (CL) is a significant contributor to overall performance degradation.
Tailored interfaces of unencapsulated perovskite solar cells for >1,000 hour operational stability
Christians, Jeffrey A.; Schulz, Philip; Tinkham, Jonathan S.; ...
2017-11-28
Long-term device stability is the most pressing issue that impedes perovskite solar cell commercialization, given the achieved 22.7% efficiency. The perovskite absorber material itself has been heavily scrutinized for being prone to degradation by water, oxygen and ultraviolet light. To date, most reports characterize device stability in the absence of these extrinsic factors. Here we show that, even under the combined stresses of light (including ultraviolet light), oxygen and moisture, perovskite solar cells can retain 94% of peak efficiency despite 1,000 hours of continuous unencapsulated operation in ambient air conditions (relative humidity of 10-20%). Each interface and contact layer throughoutmore » the device stack plays an important role in the overall stability which, when appropriately modified, yields devices in which both the initial rapid decay (often termed burn-in) and the gradual slower decay are suppressed. This extensively modified device architecture and the understanding developed will lead towards durable long-term device performance.« less
Tailored interfaces of unencapsulated perovskite solar cells for >1,000 hour operational stability
NASA Astrophysics Data System (ADS)
Christians, Jeffrey A.; Schulz, Philip; Tinkham, Jonathan S.; Schloemer, Tracy H.; Harvey, Steven P.; Tremolet de Villers, Bertrand J.; Sellinger, Alan; Berry, Joseph J.; Luther, Joseph M.
2018-01-01
Long-term device stability is the most pressing issue that impedes perovskite solar cell commercialization, given the achieved 22.7% efficiency. The perovskite absorber material itself has been heavily scrutinized for being prone to degradation by water, oxygen and ultraviolet light. To date, most reports characterize device stability in the absence of these extrinsic factors. Here we show that, even under the combined stresses of light (including ultraviolet light), oxygen and moisture, perovskite solar cells can retain 94% of peak efficiency despite 1,000 hours of continuous unencapsulated operation in ambient air conditions (relative humidity of 10-20%). Each interface and contact layer throughout the device stack plays an important role in the overall stability which, when appropriately modified, yields devices in which both the initial rapid decay (often termed burn-in) and the gradual slower decay are suppressed. This extensively modified device architecture and the understanding developed will lead towards durable long-term device performance.
Adamo, Federica; Farina, Marco; Thekkedath, Usha R; Grattoni, Alessandro; Sesana, Raffaella
2018-06-01
Cell transplantation in bioengineered scaffolds and encapsulation systems has shown great promise in regenerative medicine. Depending on the site of implantation, type of cells and their expected function, these systems are designed to provide cells with a physiological-like environment while providing mechanical support and promoting long-term viability and function of the graft. A minimally invasive 3D printed system termed neovascularized implantable cell homing and encapsulation (NICHE) was developed in polylactic acid for subcutaneous transplantation of endocrine cells, including pancreatic islets. The suitability of the NICHE for long term in vivo deployment is investigated by assessing mechanical behavior of both fresh devices under simulated subcutaneous conditions and NICHE retrieved from subcutaneous implantation in pigs. Both experimental and numerical studies were performed with a focus on validating the constitutive material model used in the numerical analysis for accuracy and reliability. Notably, homogeneous isotropic constitutive material model calibrated by means of uniaxial testing well suited experimental results. The results highlight the long term durability for in vivo applications and the potential applicability of the model to predict the mechanical behavior of similar devices in various physiological settings. Copyright © 2018 Elsevier Ltd. All rights reserved.
Long-term micro-Deval durability of andesite aggregate
NASA Astrophysics Data System (ADS)
Czinder, Balázs; Török, Ákos
2017-04-01
Micro-Deval tests have been intensively used for analysing aggregate durability. The tests procedure described in details in the European Norm (EN 1097-1:2011). The current research intends to evaluate the long term durability of andesite aggregate by using extended micro-Deval tests. Andesite aggregate from Recsk (Hungary) was used for the tests. The tested andesite is a massive porphyritic biotite amphibol andesite that was formed during Eocene volcanism and forms a part of Mátra Mountains volcanic complex in NE Hungary. The aggregates were crushed and screened. Size fractions of 10.0/14.0 mm representing minimum and maximum grain sizes were used in the tests. 500 g of aggregate specimens were loaded in the steel drum and 2500 ml of water was added besides the 5000 g of steel balls into the device. The steel balls have a diameter of 10 mm according to EN. The test material - in the first stage - was subjected to 12,000 revolutions in the drum. This number is suggested by the EN. The micro-Deval coefficient was calculated after this first stage. Further wear of the andesitic material was tested by using additional revolutions. The increase in revolutions of the drum was in 12,000 rotation steps, reached 48,000 revolutions as a maximum. The tests were aimed to model the wear of aggregate on a longer term. It was also used to assess the durability of the aggregate when it is applied in engineering structures. The micro-Deval test results suggest that additional revolutions caused additional loss in material, i.e. increase in micro-Deval coefficient. A correlation is suggested between the revolution and andesite wear.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goldberg, Louise F.; Harmon, Anna C.
2015-04-01
Thermal and moisture problems in existing basements create a unique challenge because the exterior face of the wall is not easily or inexpensively accessible. This approach addresses thermal and moisture management from the interior face of the wall without disturbing the exterior soil and landscaping. the interior and exterior environments. This approach has the potential for improving durability, comfort, and indoor air quality. This project was funded jointly by the National Renewable Energy Laboratory (NREL) and Oak Ridge National Laboratory (ORNL). ORNL focused on developing a full basement wall system experimental database to enable others to validate hygrothermal simulation codes.more » NREL focused on testing the moisture durability of practical basement wall interior insulation retrofit solutions for cold climates. The project has produced a physically credible and reliable long-term hygrothermal performance database for retrofit foundation wall insulation systems in zone 6 and 7 climates that are fully compliant with the performance criteria in the 2009 Minnesota Energy Code. The experimental data were configured into a standard format that can be published online and that is compatible with standard commercially available spreadsheet and database software.« less
Modified fabrication techniques lead to improved centrifugal blood pump performance.
Pacella, J J; Goldstein, A H; Magovern, G J; Clark, R F
1994-01-01
The authors are developing an implantable centrifugal blood pump for short- and medium-term (1-6 months) left ventricular assist. They hypothesized that the application of result dependent modifications to this pump would lead to overall improved performance in long-term implantation studies. Essential requirements for pump operation, such as durability and resistance to clot formation, have been achieved through specialized fabrication techniques. The antithrombogenic character of the pump has been improved through coating at the cannula-housing interfaces and the baffle seal, and through changing the impeller blade material from polysulfone to pyrolytic carbon. The electronic components of the pump have been sealed for implantable use through specialized processes of dipping and potting, and the surfaces of the internal pump components have been treated to increase durability. The device has demonstrated efficacy in five chronic sheep implantation studies of 14, 10, 28, 35, and 154 day duration. Post mortem findings from the 14 day experiment showed stable fibrin entangled around the impeller shaft and blades. After pump modification, autopsy findings of the 10 day study showed no evidence of clot. Additionally, the results of the 28 day experiment showed only a small (2.0 mm) ring of fibrin at the shaft-seal interface. In the 35 and 154 day experiments, redesign of the stators have resulted in improved motor corrosion resistance. The 35 day study showed a small, 0.5 mm wide fibrin deposit at the lip seal, but no motor failure. In the 154 day experiment, the motor failed because of stator fluid corrosion, while the explanted pump was devoid of thrombus. Based on these findings, the authors believe that these pump refinements have contributed significantly to improvements in durability and resistance to clot formation.
NASA Astrophysics Data System (ADS)
Huynh, Trong-Phuoc; Hwang, Chao-Lung; Yang, Shu-Ti
2017-12-01
This experimental study evaluated the performance of normal ordinary Portland cement (OPC) concrete and high-performance concrete (HPC) that were designed by the conventional method (ACI) and densified mixture design algorithm (DMDA) method, respectively. Engineering properties and durability performance of both the OPC and HPC samples were studied using the tests of workability, compressive strength, water absorption, ultrasonic pulse velocity, and electrical surface resistivity. Test results show that the HPC performed good fresh property and further showed better performance in terms of strength and durability as compared to the OPC.
Schellenberger, S; Gillgard, P; Stare, A; Hanning, A; Levenstam, O; Roos, S; Cousins, I T
2018-02-01
Fluorinated durable water repellent (DWR) agents are used to obtain water and stain repellent textiles. Due to the on-going phase-out of DWRs based on side-chain fluorinated polymers (SFP) with "long" perfluoroalkyl chains, the textile industry lacks suitable alternatives with comparable material characteristics. The constant development and optimization of SFPs for textile applications initiated more than half a century ago has resulted in a robust and very efficient DWR-technology and textiles with exceptional hydro- and oleo-phobic properties. The industry is now in the predicament that the long-chain SFPs with the best technical performance have undesirable toxicological and environmental behaviour. This study provides a comprehensive overview of the technical performance of presently available fluorinated and non-fluorinated DWRs as part of a chemical alternatives assessment (CAA). The results are based on a study with synthetic outdoor fabrics treated with alternative DWRs and tested for repellency using industrial standard and complementary methods. Using this approach, the complex structure-property relationships of DWR-polymers could be explained on a molecular level. Both short-chain SFPs and non-fluorinated DWRs showed excellent water repellency and durability in some cases while short-chain SFPs were the more robust of the alternatives to long-chain SFPs. A strong decline in oil repellency and durability with perfluoroalkyl chain length was shown for SFP DWRs. Non-fluorinated alternatives were unable to repel oil, which might limit their potential for substitution in textile application that require repellency towards non-polar liquids. Copyright © 2017. Published by Elsevier Ltd.
Aortic Valve Replacement With the Stentless Freedom SOLO Bioprosthesis: A Systematic Review.
Wollersheim, Laurens W; Li, Wilson W; Bouma, Berto J; Repossini, Alberto; van der Meulen, Jan; de Mol, Bas A
2015-10-01
This systematic review examined the clinical and hemodynamic performance of the stentless Freedom SOLO (Sorin Group, Milan, Italy) aortic bioprosthesis. The occurrence of postoperative thrombocytopenia was also analyzed. The Freedom SOLO is safe to use in everyday practice, with short cross-clamp times, and postoperative pacemaker implantation is notably lower. Valvular gradients are low and remain stable during short-term follow-up. Thrombocytopenia is more severe than in other aortic prostheses; however, this is without clinical consequences. Within a few years, the 15-year follow-up of this bioprosthesis will be known, which will be key to evaluating its long-term durability. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Yakunin, Alexander N.; Aban'shin, Nikolay P.; Avetisyan, Yuri A.; Akchurin, Georgy G.; Loginov, Alexander P.; Mosiyash, Denis S.; Akchurin, Garif G.
2018-04-01
The paper provides a justification and a comparative analysis of the scaling directions of the developed and investigated planar triode field emission cathode unit with the aim of increasing the maximum field current density up to 0.75 A-cm-2 without sacrificing durability. The design features of the vacuum device with a planar structure provided low-voltage control - at 150 V in the mode of long-term durability and not more than 250 V in the mode of the maximum permissible emission current.
Evidence-based outcomes of holmium laser enucleation of the prostate.
Large, Tim; Krambeck, Amy E
2018-05-01
Holmium laser enucleation of the prostate (HoLEP) has been a mainstay therapy for the treatment of lower urinary tract symptoms (LUTS) secondary to benign prostate hyperplasia (BPH) for nearly 20 years. We briefly review current and sentinel publications that provide outcomes data after HoLEP. Current literature continues to support HoLEP as a versatile and durable surgical option for men with LUTS secondary to BPH. Despite evidence supporting durable symptom relief beyond 10 years even in large prostate glands, HoLEP is still not widely available to all patients. Concerns surrounding the learning curve of the procedure, high rates of retrograde ejaculation, and transient urinary incontinence seem to persist and limit the adoption of HoLEP by established urologists and residency training programs. Recent publications continue to show excellent short-term and long-term outcomes after HoLEP, in the categories of voiding function and patient satisfaction. Continued attempts to demonstrate equivalent outcomes of alternate-BPH surgical techniques are being met with renewed efforts by those performing HoLEP to demonstrate equivalent outcomes and patient safety during the learning phase of HoLEP for both mentored and self-directed surgical training.
Tsuchiya, Kenji; Takamizawa, Toshiki; Barkmeier, Wayne W; Tsubota, Keishi; Tsujimoto, Akimasa; Berry, Thomas P; Erickson, Robert L; Latta, Mark A; Miyazaki, Masashi
2016-02-01
The present study aimed to determine the effect of the functional monomer, 10-methacryloxydecyl dihydrogen phosphate (MDP), on the enamel bond durability of single-step self-etch adhesives through integrating fatigue testing and long-term water storage. An MDP-containing self-etch adhesive, Clearfil Bond SE ONE (SE), and an experimental adhesive, MDP-free (MF), which comprised the same ingredients as SE apart from MDP, were used. Shear bond strength (SBS) and shear fatigue strength (SFS) were measured with or without phosphoric acid pre-etching. The specimens were stored in distilled water for 24 h, 6 months, or 1 yr. Although similar SBS and SFS values were obtained for SE with pre-etching and for MF after 24 h of storage in distilled water, SE with pre-etching showed higher SBS and SFS values than MF after storage in water for 6 months or 1 yr. Regardless of the pre-etching procedure, SE showed higher SBS and SFS values after 6 months of storage in distilled water than after 24 h or 1 yr. To conclude, MDP might play an important role in enhancing not only bond strength but also bond durability with respect to repeated subcritical loading after long-term water storage. © 2015 Eur J Oral Sci.
Adjuvant-enhanced CD4 T Cell Responses are Critical to Durable Vaccine Immunity.
Martins, Karen A O; Cooper, Christopher L; Stronsky, Sabrina M; Norris, Sarah L W; Kwilas, Steven A; Steffens, Jesse T; Benko, Jacqueline G; van Tongeren, Sean A; Bavari, Sina
2016-01-01
Protein-based vaccines offer a safer alternative to live-attenuated or inactivated vaccines but have limited immunogenicity. The identification of adjuvants that augment immunogenicity, specifically in a manner that is durable and antigen-specific, is therefore critical for advanced development. In this study, we use the filovirus virus-like particle (VLP) as a model protein-based vaccine in order to evaluate the impact of four candidate vaccine adjuvants on enhancing long term protection from Ebola virus challenge. Adjuvants tested include poly-ICLC (Hiltonol), MPLA, CpG 2395, and alhydrogel. We compared and contrasted antibody responses, neutralizing antibody responses, effector T cell responses, and T follicular helper (Tfh) cell frequencies with each adjuvant's impact on durable protection. We demonstrate that in this system, the most effective adjuvant elicits a Th1-skewed antibody response and strong CD4 T cell responses, including an increase in Tfh frequency. Using immune-deficient animals and adoptive transfer of serum and cells from vaccinated animals into naïve animals, we further demonstrate that serum and CD4 T cells play a critical role in conferring protection within effective vaccination regimens. These studies inform on the requirements of long term immune protection, which can potentially be used to guide screening of clinical-grade adjuvants for vaccine clinical development.
The power of disruptive technological innovation: Transcatheter aortic valve implantation.
Berlin, David B; Davidson, Michael J; Schoen, Frederick J
2015-11-01
We sought to evaluate the principles of disruptive innovation, defined as technology innovation that fundamentally shifts performance and utility metrics, as applied to transcatheter aortic valve implantation (TAVI). In particular, we considered implantation procedure, device design, cost, and patient population. Generally cheaper and lower performing, classical disruptive innovations are first commercialized in insignificant markets, promise lower margins, and often parasitize existing usage, representing unattractive investments for established market participants. However, despite presently high unit cost, TAVI is less invasive, treats a "new," generally high risk, patient population, and is generally done by a multidisciplinary integrated heart team. Moreover, at least in the short-term TAVI has not been lower-performing than open surgical aortic valve replacement in high-risk patients. We conclude that TAVI extends the paradigm of disruptive innovation and represents an attractive commercial opportunity space. Moreover, should the long-term performance and durability of TAVI approach that of conventional prostheses, TAVI will be an increasingly attractive commercial opportunity. © 2014 Wiley Periodicals, Inc.
In situ metal ion contamination and the effects on proton exchange membrane fuel cell performance
NASA Astrophysics Data System (ADS)
Sulek, Mark; Adams, Jim; Kaberline, Steve; Ricketts, Mark; Waldecker, James R.
Automotive fuel cell technology has made considerable progress, and hydrogen fuel cell vehicles are regarded as a possible long-term solution to reduce carbon dioxide emissions, reduce fossil fuel dependency and increase energy efficiency. Even though great strides have been made, durability is still an issue. One key challenge is controlling MEA contamination. Metal ion contamination within the membrane and the effects on fuel cell performance were investigated. Given the possible benefits of using stainless steel or aluminum for balance-of-plant components or bipolar plates, cations of Al, Fe, Ni and Cr were studied. Membranes were immersed in metal sulfide solutions of varying concentration and then assembled into fuel cell MEAs tested in situ. The ranking of the four transition metals tested in terms of the greatest reduction in fuel cell performance was: Al 3+ ≫ Fe 2+ > Ni 2+, Cr 3+. For iron-contaminated membranes, no change in cell performance was detected until the membrane conductivity loss was greater than approximately 15%.
Evaluation of PCC long-term durability using intermediate sized gravels to optimize mix gradations.
DOT National Transportation Integrated Search
2010-04-01
With the implementation of the 2000 Q-MC specification, an incentive is provided to produce an optimized gradation to improve placement characteristics. Also, specifications for slip-formed barrier rail have changed to require an optimized gradation....
Surface resistivity as an alternative for rapid chloride permeability test of hardened concrete.
DOT National Transportation Integrated Search
2015-03-01
Kansas experiences harsh winters that require frequent use of de-icing salts, making it critical to the long-term : durability of concrete structures that the permeability is kept under control. Under current KDOT specification, the : Rapid Chloride ...
Long-term durability of geosynthetics based on exhumed samples from construction projects
DOT National Transportation Integrated Search
2001-04-01
This report presents the results of mechanical and chemical tests on 24 retrieved geosynthetics from 12 sites, across the United States and provides a baseline databank of mechanical and chemical properties of many commonly used geosynthesis in trans...
Isaacson, Stuart; Shill, Holly A; Vernino, Steven; Ziemann, Adam; Rowse, Gerald J
2016-10-19
Neurogenic orthostatic hypotension (nOH) is associated with insufficient norepinephrine release in response to postural change. The objective of this study was to evaluate the long-term safety and durability of efficacy of the norepinephrine precursor droxidopa in patients with symptomatic nOH. This multinational study consisted of 3 sequential phases: a 3-month open-label droxidopa treatment phase followed by a 2-week double-blind, placebo-controlled withdrawal phase, and a 9-month open-label extension phase in which all patients received droxidopa. Patients were adults diagnosed with symptomatic nOH associated with Parkinson's disease, multiple system atrophy, pure autonomic failure, dopamine β-hydroxylase deficiency, or nondiabetic autonomic neuropathy. Efficacy was evaluated using patient- and investigator-reported questionnaire responses and the orthostatic standing test. Safety was assessed through adverse event (AE) reports and vital signs. A total of 102 patients received treatment with droxidopa. Initial improvements from baseline in patient-reported nOH symptom severity and impact on daily activities, evaluated using the Orthostatic Hypotension Questionnaire, exceeded 50% and were maintained throughout the 12-month study. Decreased nOH severity was also reflected in clinician and patient ratings on the Clinical Global Impression questionnaire. Standing systolic and diastolic blood pressures were increased from baseline throughout the study with droxidopa treatment. The most frequently reported AEs were falls, urinary tract infection, and headache. There was a low incidence (≤2%) of cardiac AEs (eg, first-degree atrioventricular block, supraventricular extrasystoles). Long-term, open-label treatment with droxidopa for up to 12 months was generally well tolerated and provided durable improvements in nOH signs and symptoms.
Effects of surface preparation on the long-term durability of adhesively bonded composite joints
NASA Astrophysics Data System (ADS)
Bardis, Jason Dante
The long-term durability of adhesively bonded composite joints is critical to modern aircraft structures, which are increasingly adopting bonding as an alternative option to mechanical fastening. The effects of the surface preparation of the adherends are critical, affecting initial strength, long-term durability, fracture toughness, and failure modes of bonded joints. In this study, several potential factors are evaluated, with focus on the following: (1) Effects of possible chemical contamination from release fabrics, release films, and peel plies during adherend cure. (2) Chemical and mechanical effects of abrasion on the fracture toughness and failure mode. (3) Characterization of paste and film adhesives. There are several standard test methods used to evaluate specimen fracture, but the majority concentrate on bonded metals and interlaminar composite fracture. Testing concentrated on mode I tests; a custom double cantilever beam specimen was devised and utilized, and two forms of a wedge crack test (traveling and static) were also used. Additionally, single lap shear tests were run to contrast the mode I tests. Non-destructive testing included X-ray photography of crack fronts, energy dispersive spectroscopy and X-ray photoelectron spectroscopy surface chemistry analyses, and scanning electron microscope imaging of prepared surfaces. All mode I test methods tended to be in agreement in the ranking of different surface preparation methods. Test results revealed that release agents deposited on adherend surfaces during their cure cycle prevented proper adhesion. While mechanical abrasion did improve their fracture toughness and lower their contamination greatly, the test values did not reach the levels of samples that were not contaminated before bonding, and the interfacial modes of failure did not always change to desirable modes.
McEvoy, Joseph P; Risinger, Robert; Mykhnyak, Serhiy; Du, Yangchun; Liu, Chih-Chin; Stanford, Arielle D; Weiden, Peter J
To evaluate durability of therapeutic effect of long-term treatment with aripiprazole lauroxil in patients with schizophrenia following successful treatment of an acute psychotic episode. This post hoc analysis assessed long-term outcomes for a subgroup of patients who entered a 52-week extension study after being successfully stabilized with one of 2 doses of aripiprazole lauroxil (441 or 882 mg) in a pivotal 12-week, placebo-controlled, randomized clinical trial. Durability of therapeutic effect was measured by the proportion of patients completing the 1-year course of aripiprazole lauroxil, the trajectories of the Positive and Negative Syndrome Scale (PANSS) total and the Clinical Global Impression-Severity (CGI-S) item scores beyond the first 12 weeks, and the likelihood of remission at any follow-up point. In total, 181 patients treated with aripiprazole lauroxil entered the extension study; 73% and 66% of patients from the 441 mg and 882 mg groups, respectively, completed all 13 aripiprazole lauroxil treatments scheduled every 4 weeks over 52 weeks. Both groups continued on a positive trajectory of symptom improvements (P < .0001 for reductions in PANSS total and CGI-S scores from week 12 to end of follow-up). Most patients (74% and 68% in the aripiprazole lauroxil 441 mg and 882 mg groups, respectively) achieved remission during follow-up. These post hoc analyses of a subgroup of patients demonstrate the continued therapeutic efficacy of aripiprazole lauroxil after successful treatment of an acute episode of schizophrenia. Both the 441 mg and 882 mg groups had similar retention rates, degree of symptom improvement, and likelihood of remission. ClinicalTrials.gov identifier: NCT01469039; European Clinical Trials Database (EudraCT) numbers: 2012-003445-15 and 2012-003996-20. © Copyright 2017 Physicians Postgraduate Press, Inc.
Reed, C C; Fan, C; Koutlas, N T; Shaheen, N J; Dellon, E S
2017-11-01
Limited data describe the long-term efficacy of dietary elimination in eosinophilic oesophagitis (EoE). To assess the long-term outcomes of food elimination diets for treatment of adults with EoE. We conducted a retrospective cohort study at our centre analysing all EoE patients receiving a food elimination diet without concomitant steroids. Baseline data were abstracted using standardised collection forms. Follow-up data from a mean 24.9-month period were collected for patients with a histological response to a food elimination diet during and after food reintroduction. The main outcomes were symptomatic, endoscopic and histological responses. Of 52 patients, 18 received a 6-food food elimination diet, 32 received targeted diet, and two received a 6-food food elimination diet with targeted elimination. There were 21 (40%) patients with an initial histological response. Responders reported less dysphagia after treatment (95% baseline vs 11%; P = .001) and at the end of follow-up (95% baseline vs 33%; P = .008). Significant and durable endoscopic improvements were recorded at the same time points: Endoscopic reference score: 3.2 vs 0.7; P = .001; and 3.2 vs 1.7; P = .06. Histological findings improved after the most restrictive diet in responders (49.8 vs 4.1 eosinophils per high-power field; P = .001) and remained suppressed in the 10 initial responders maintaining compliance at the end of follow-up (5.2 eosinophils per high-power field). Among EoE patients responding to a food elimination diet and remaining adherent, maintenance dietary therapy produced durable long-term symptomatic, endoscopic and histological disease control. These long-term data confirm that a food elimination diet is an effective maintenance treatment option in select adults with EoE. © 2017 John Wiley & Sons Ltd.
Durability Improvement of Pt/RGO Catalysts for PEMFC by Low-Temperature Self-Catalyzed Reduction.
Sun, Kang Gyu; Chung, Jin Suk; Hur, Seung Hyun
2015-12-01
Pt/C catalyst used for polymer electrolyte membrane fuel cells (PEMFCs) displays excellent initial performance, but it does not last long because of the lack of durability. In this study, a Pt/reduced graphene oxide (RGO) catalyst was synthesized by the polyol method using ethylene glycol (EG) as the reducing agent, and then low-temperature hydrogen bubbling (LTHB) treatment was introduced to enhance the durability of the Pt/RGO catalyst. The cyclic voltammetry (CV), oxygen reduction reaction (ORR) analysis, and transmittance electron microscopy (TEM) results suggested that the loss of the oxygen functional groups, because of the hydrogen spillover and self-catalyzed dehydration reaction during LTHB, reduced the carbon corrosion and Pt agglomeration and thus enhanced the durability of the electrocatalyst.
Barkagan, Michael; Contreras-Valdes, Fernando M; Leshem, Eran; Buxton, Alfred E; Nakagawa, Hiroshi; Anter, Elad
2018-05-30
PV reconnection is often the result of catheter instability and tissue edema. High-power short-duration (HP-SD) ablation strategies have been shown to improve atrial linear continuity in acute pre-clinical models. This study compares the safety, efficacy and long-term durability of HP-SD ablation with conventional ablation. In 6 swine, 2 ablation lines were performed anterior and posterior to the crista terminalis, in the smooth and trabeculated right atrium, respectively; and the right superior PV was isolated. In 3 swine, ablation was performed using conventional parameters (THERMOCOOL-SMARTTOUCH ® SF; 30W/30 sec) and in 3 other swine using HP-SD parameters (QDOT-MICRO™, 90W/4 sec). After 30 days, linear integrity was examined by voltage mapping and pacing, and the heart and surrounding tissues were examined by histopathology. Acute line integrity was achieved with both ablation strategies; however, HP-SD ablation required 80% less RF time compared with conventional ablation (P≤0.01 for all lines). Chronic line integrity was higher with HP-SD ablation: all 3 posterior lines were continuous and transmural compared to only 1 line created by conventional ablation. In the trabeculated tissue, HP-SD ablation lesions were wider and of similar depth with 1 of 3 lines being continuous compared to 0 of 3 using conventional ablation. Chronic PVI without stenosis was evident in both groups. There were no steam-pops. Pleural markings were present in both strategies, but parenchymal lung injury was only evident with conventional ablation. HP-SD ablation strategy results in improved linear continuity, shorter ablation time, and a safety profile comparable to conventional ablation. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Diment, Laura E; Thompson, Mark S; Bergmann, Jeroen HM
2017-01-01
Background: Three-dimensional printing provides an exciting opportunity to customise upper-limb prostheses. Objective: This review summarises the research that assesses the efficacy and effectiveness of three-dimensional printed upper-limb prostheses. Study design: Systematic review. Methods: PubMed, Web of Science and OVID were systematically searched for studies that reported human trials of three-dimensional printed upper-limb prostheses. The studies matching the language, peer-review and relevance criteria were ranked by level of evidence and critically appraised using the Downs and Black Quality Index. Results: After removing duplicates, 321 records were identified. Eight papers met the inclusion criteria. No studies used controls; five were case studies and three were small case-series studies. All studies showed promising results, but none demonstrated external validity, avoidance of bias or statistically significant improvements over conventional prostheses. The studies demonstrated proof-of-concept rather than assessing efficacy, and the devices were designed to prioritise reduction of manufacturing costs, not customisability for comfort and function. Conclusion: The potential of three-dimensional printing for individual customisation has yet to be fully realised, and the efficacy and effectiveness to be rigorously assessed. Until randomised controlled trials with follow-up are performed, the comfort, functionality, durability and long-term effects on quality of life remain unknown. Clinical relevance Initial studies suggest that three-dimensional printing shows promise for customising low-cost upper-limb prosthetics. However, the efficacy and effectiveness of these devices have yet to be rigorously assessed. Until randomised controlled trials with follow-up are performed, the comfort, functionality, durability and long-term effects on patient quality of life remain unknown. PMID:28649911
DiBardino, Daniel J; ElBardissi, Andrew W; McClure, R Scott; Razo-Vasquez, Ozwaldo A; Kelly, Nicole E; Cohn, Lawrence H
2010-01-01
To determine the long-term outcomes of mitral valvuloplasty for myxomatous valve disease, rheumatic valve disease, and functional mitral regurgitation. A total of 1503 patients underwent mitral valvuloplasty by a single surgeon between February 1972 and April 2008 and were retrospectively reviewed for short- and long-term results. Overall mean age was 60.3 + or - 13.7 years, and 57% were male. The cause was rheumatic in 193 patients, myxomatous in 1042 patients, and ischemic and nonischemic functional mitral regurgitation in 236 patients. Ring annuloplasty was performed in 1306 patients (87%). Commissurotomy was the primary repair for rheumatic valves, posterior leaflet resection and reconstruction was the most common repair for myxomatous valves (527/1042 [51%]), and ring reduction annuloplasty was the primary operation for functional mitral regurgitation. The 30-day mortality was 19 of 1503 patients (1.3%) and significantly higher in the functional mitral regurgitation group (11/236 patients, 4.7% vs 0.5% in the rheumatic group and 0.6% in the myxomatous group, P < .01). The 10-, 20-, and 30-year survivals were similar for the rheumatic and myxomatous groups (77%, 56%, and 39% vs 79%, 62%, and 52%, respectively) but significantly less for the functional mitral regurgitation group (44%, 4%, and 0%, respectively, log-rank P < .0001). The 10- and 20-year freedom from reoperation rates were significantly better for the myxomatous group than for the rheumatic group (90% and 82% vs 66% and 34%, log-rank P < .0001), with a 30-year freedom from reoperation of only 10% for rheumatic repair. In the myxomatous group, freedom from reoperation was lower in patients with anterior leaflet pathology (P = .0008). Follow-up data to 36 years demonstrate that cause strongly determines survival and durability of mitral valvuloplasty; patients with rheumatic valve disease who survive more than 20 years require reoperation, whereas functional mitral regurgitation carries the highest short- and long-term mortality rates and lowest freedom from reoperation. Mitral valvuloplasty for myxomatous valves demonstrates the longest durability, with many patients free from reoperation at 30 years. Copyright 2010 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Martin, Caitlin; Sun, Wei
2015-01-01
Transcatheter aortic valve (TAV) intervention is now the standard-of-care treatment for inoperable patients and a viable alternative treatment option for high-risk patients with symptomatic aortic stenosis. While the procedure is associated with lower operative risk and shorter recovery times than traditional surgical aortic valve (SAV) replacement, TAV intervention is still not considered for lower-risk patients due in part to concerns about device durability. It is well known that bioprosthetic SAVs have limited durability, and TAVs are generally assumed to have even worse durability, yet there is little long-term data to confirm this suspicion. In this study, TAV and SAV leaflet fatigue due to cyclic loading was investigated through finite element analysis by implementing a computational soft tissue fatigue damage model to describe the behavior of the pericardial leaflets. Under identical loading conditions and with identical leaflet tissue properties, the TAV leaflets sustained higher stresses, strains, and fatigue damage compared to the SAV leaflets. The simulation results suggest that the durability of TAVs may be significantly reduced compared to SAVs to about 7.8 years. The developed computational framework may be useful in optimizing TAV design parameters to improve leaflet durability, and assessing the effects of underexpanded, elliptical, or non-uniformly expanded stent deployment on TAV durability. PMID:26294354
Temperature induced effects on the durability of MR fluids
NASA Astrophysics Data System (ADS)
Wiehe, A.; Kieburg, C.; Maas, J.
2013-02-01
Although commercial MR fluids exist for quite some time now and the feasibility as well as the advantages of the MR technology have been demonstrated for several applications by a variety of MR actuator prototypes, a sustainable market break-through of brake and clutch applications utilizing the shear mode is still missing. Essential impediments are the marginal knowledge about the durability of the MR technology. To overcome this situation, a long-term measurement system was developed for the durability analysis of MR fluid formulations within a technical relevant scale with respect to the volume of MR fluid and the transmitted torque. The focus of the presented series of measurements is given to the analysis of temperature induced effects on the durability. In this context four different failure indicators can be distinguished, namely an apparent negative viscosity, deviations in torque data obtained from different measurements as well as a pressure increase and a drop in the on-state torque. The measurement data of the present durability experiments indicate a significant dependency of the attainable energy intake density on the temperature. The aim of such durability tests is to establish a reliable data base for the industry to estimate the life-time of MR devices.
DOT National Transportation Integrated Search
2009-01-01
Early-age cracking, typically caused by drying shrinkage (and often coupled with autogenous and thermal : shrinkage), can have several detrimental effects on long-term behavior and durability. Cracking can also provide : ingress of water that can dri...
DOT National Transportation Integrated Search
2015-03-01
Kansas experiences harsh winters that require frequent use of de-icing salts, making it : critical to the long-term durability of concrete structures that the permeability is kept : under control. Under current KDOT specification, the Rapid Chloride ...
Water Absorption Behavior of Hemp Hurds Composites
Stevulova, Nadezda; Cigasova, Julia; Purcz, Pavol; Schwarzova, Ivana; Kacik, Frantisek; Geffert, Anton
2015-01-01
In this paper, water sorption behavior of 28 days hardened composites based on hemp hurds and inorganic binder was studied. Two kinds of absorption tests on dried cube specimens in deionized water bath at laboratory temperature were performed. Short-term (after one hour water immersion) and long-term (up to 180 days) water absorption tests were carried out to study their durability. Short-term water sorption behavior of original hemp hurds composites depends on mean particle length of hemp and on binder nature. The comparative study of long-term water sorption behavior of composites reinforced with original and chemically modified hemp hurds in three reagents confirmed that surface treatment of filler influences sorption process. Based on evaluation of sorption curves using a model for composites based on natural fibers, diffusion of water molecules in composite reinforced with original and chemically modified hemp hurds is anomalous in terms of the Fickian behavior. The most significant decrease in hydrophility of hemp hurds was found in case of hemp hurds modified by NaOH and it relates to change in the chemical composition of hemp hurds, especially to a decrease in average degree of cellulose polymerization as well as hemicellulose content.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Linard, Joshua; Hall, Steve
9.1 Compliance Summary The Lakeview, Oregon, Uranium Mill Tailings Radiation Control Act (UMTRCA) Title I Disposal Site was inspected September 16 and 17, 2015. Other than some ongoing concern with erosion-control rock riprap degradation, the disposal cell was in good condition. Some minor fence repairs and vegetation removal, and minor erosion repair work along the west site fence is planned. Inspectors identified no other maintenance needs or cause for a follow-up or contingency inspection. Disposal cell riprap is evaluated annually to ensure continued long-term protection of the cell from erosion during a severe precipitation event. Degradation of the rock riprapmore » was first observed at the site in the mid-1990s. Rock gradation monitoring of the riprap on the west side slope has been performed as part of the annual inspection since 1997 to determine the mean diameter (D 50) value. As prescribed by the monitoring procedure, the rock monitoring is routinely conducted at random locations. However, at the U.S. Nuclear Regulatory Commission’s (NRC’s) request, the 2015 rock monitoring approach deviated from the normal procedure by using a pre-established monitoring grid in a subset area of the west side slope. This changed the monitoring approach from random sampling to biased sampling. The D 50 value measured during the 2015 gradation monitoring is 2.39 inches, which falls below the original D 50 design size range of 2.7–3.9 inches for the Type B size side slope riprap. At NRC’s request, rock durability monitoring was added to the gradation monitoring in 2009 to monitor durability by rock type. Results of the 2015 durability monitoring showed that74 percent of the total rock sampled is durability class code A rock with an assigned durability class of “highly durable” or durability class code B “durable” rock, and that over 90 percent of the 3-inch or larger rock is durability class code A or B. The rock durability classifications are further explained in Section 9.4.2.2.« less
Internal curing of high-performance concrete for bridge decks.
DOT National Transportation Integrated Search
2013-03-01
High performance concrete (HPC) provides a long lasting, durable concrete that is typically used in bridge decks due to its low permeability, high abrasion resistance, freeze-thaw resistance and strength. However, this type of concrete is highly susc...
Long-term performance of the Hancock bioprosthetic valved conduit in the aortic root position.
Badiu, Catalin C; Bleiziffer, Sabine; Eichinger, Walter B; Hettich, Ina; Krane, Markus; Bauernschmitt, Robert; Lange, Rüdiger
2011-03-01
The study aim was to assess long-term morbidity and mortality with special regard to prosthesis durability after aortic root replacement with the Hancock bioprosthetic porcine conduit. Between 1975 and 2004, a total of 81 patients (55 males, 26 females; mean age 58 +/- 18 years) underwent aortic root replacement with the Hancock conduit for aortic dissection (n = 22; 27%), ascending aortic aneurysm (n = 57; 70%), or porcelain aorta (n = 2; 3%). Twenty-five patients (31%) underwent an emergency operation, 12 (15%) presented with Marfan syndrome, and eight (10%) had undergone previous cardiac surgery. Concomitant procedures were performed in 26 cases (32%). The follow up was 98% complete; the mean follow up was 4.8 +/- 4.0 years (range: 1 day to 16.7 years), and the cumulative follow up was 403 patient-years. Actuarial event-free rates were calculated, and valve-related complications classified according to guidelines for reporting morbidity and mortality after cardiac valvular operations. There were seven (9%) operative deaths and four (5%) in-hospital deaths. Actuarial survival rates at five and 10 years (excluding operative deaths) were 77.0 +/- 5.3% and 54.0 +/- 7.5%, respectively. Actuarial freedom from aortic valve reoperation at five and 10 years was 98 +/- 1.6% and 64 +/- 10.2%, from structural valve deterioration 88.1 +/- 4.7% and 49.9 +/- 9.6%, from thromboembolic events 87.4 +/- 4.6% and 75.1 +/- 9.5%, and from major bleeding events 90.2 +/- 3.9% and 75.4 +/- 8.1%, respectively. Among redo procedures, the stentless Hancock valve could be excised without separating the synthetic graft from the left ventricular outflow tract, and a stented valve prosthesis thus implanted. Hence, it was possible to avoid a second Bentall operation. The long-term survival rates after aortic root replacement with the bioprosthetic Hancock conduit were reasonable for this demanding patient cohort. However, the durability of the prosthesis was inferior to that reported for the stented Hancock valve substitute. The key benefit of this bioprosthetic valved conduit was the simplified redo procedure.
deBruyn, Jennifer C; Jacobson, Kevan; El-Matary, Wael; Carroll, Matthew; Wine, Eytan; Wrobel, Iwona; Van Woudenberg, Mariel; Huynh, Hien Q
2018-02-01
Data on long-term real-world outcomes of infliximab in pediatric Crohn disease are limited. The aim of the study was to evaluate infliximab optimization and durability in children with Crohn disease. We performed a retrospective review of children with Crohn disease who started infliximab from January 2008 to December 2012 in 4 Canadian tertiary care centers. A priori factors associated with optimization and discontinuation from loss of response were evaluated using logistic regression and Cox proportional hazards model, respectively. One hundred eighty children (54.4% boys) started infliximab; all completed induction. Median age at infliximab start was 14.3 years (Q1, Q3: 12.8, 15.9 years) and median time from diagnosis to infliximab start was 1.5 years (Q1, Q3: 0.6, 3.5 years). At last follow-up, 87.1% were maintained on infliximab (median duration follow-up 85.9 weeks [Q1, Q3: 43.8, 138.8 weeks]). Infliximab optimization occurred in 57.3% (dose escalation 15.2%, interval shortening 3.9%, both 38.2%), primarily due to loss of response. Younger age at diagnosis (<10 years old) and nonstricturing, nonpenetrating behavior were associated with optimization (odds ratio 6.5, 95% confidence interval [CI] 2.0-21.1 and odds ratio 2.1, 95% CI 1.0-4.2, respectively). The 1- and 2-year durability of infliximab (percentage in follow-up who were continuing on infliximab) were 95.5% (95% CI 90.4-98.3) and 91.0% (95% CI 82.4-96.3), respectively. Annual discontinuation due to loss of response occurred at 3.2% per year (95% CI 1.1-5.2). Children with Crohn disease maintain a durable response to infliximab. Optimization occurs frequently and allows for continued use. Younger age at diagnosis and nonstricturing, nonpenetrating behavior are associated with increased need for infliximab optimization.
Review on Enhanced Heat Transfer Techniques using Modern Technologies for 4S Air Cooled Engines
NASA Astrophysics Data System (ADS)
Ramasubramanian, S.; Bupesh Raja, V. K.
2017-05-01
Engine performance is a biggest challenge and a vital area of concern when it comes to automobiles. Researchers across the globe have been working decades together meticulously improvising the performance of engine in terms of efficiency. The durability of the engine components mainly depends on the thermal stress it undergoes over the period of operation. Air cooling of engine is the simplest and most desirous technique that has been adopted for ages. In this regard fins or extended surfaces are employed for effective cooling of the cylinder while in operation. The conductive and convective heat transfer rate from the cylinder to the fins and in turn from the fins to surrounding ambience determines the effective performance of the engine. In this paper an attempt is made to review and summarize the various researches that were conducted on the Fins in terms of profile geometry, number of fins, size, thickness factor, material used etc., and to bring about a long term solution with the modern technologies like nano coatings and nano materials.
Thermal Conductivity and Sintering Behavior of Advanced Thermal Barrier Coatings
NASA Technical Reports Server (NTRS)
Zhu, Dongming; Miller, Robert A.
2002-01-01
Advanced thermal barrier coatings, having significantly reduced long-term thermal conductivities, are being developed using an approach that emphasizes real-time monitoring of thermal conductivity under conditions that are engine-like in terms of temperatures and heat fluxes. This is in contrast to the traditional approach where coatings are initially optimized in terms of furnace and burner rig durability with subsequent measurement in the as-processed or furnace-sintered condition. The present work establishes a laser high-heat-flux test as the basis for evaluating advanced plasma-sprayed and physical vapor-deposited thermal barrier coatings under the NASA Ultra Efficient Engine Technology (UEET) Program. The candidate coating materials for this program are novel thermal barrier coatings that are found to have significantly reduced thermal conductivities due to an oxide-defect-cluster design. Critical issues for designing advanced low conductivity coatings with improved coating durability are also discussed.
Adhesive Bonding of Titanium to Carbon-Carbon Composites for Heat Rejection Systems
NASA Technical Reports Server (NTRS)
Cerny, Jennifer; Morscher, Gregory
2006-01-01
High temperature adhesives with good thermal conductivity, mechanical performance, and long term durability are crucial for the assembly of heat rejection system components for space exploration missions. In the present study, commercially available adhesives were used to bond high conductivity carbon-carbon composites to titanium sheets. Bonded pieces were also exposed to high (530 to 600 Kelvin for 24 hours) and low (liquid nitrogen 77K for 15 minutes) temperatures to evaluate the integrity of the bonds. Results of the microstructural characterization and tensile shear strengths of bonded specimens will be reported. The effect of titanium surface roughness on the interface microstructure will also be discussed.
Optimal use of atherectomy in critical limb ischemia.
Rundback, John H; Herman, Kevin Chaim
2014-09-01
Critical limb ischemia (CLI) is the most severe and debilitating form of peripheral arterial disease and is associated with high rates of limb loss and cardiovascular mortality. The unique physical environment of tibial occlusive disease underlying most CLI cases limits treatment options and long-term durability, with resulting frequent rates of persistent obstruction, restenosis, and reintervention. Atherectomy represents a potential strategy to improve acute and late results when treating patients with CLI. Available atherectomy devices each have specific performance characteristics, evidentiary rationale, and limitations that mandate a clear understanding of the optimal albeit evolving use of this category of interventional tools. Copyright © 2014 Elsevier Inc. All rights reserved.
Davila, G. Willy
2011-01-01
Objective. To evaluate long-term effectiveness and safety of conservative and minimally invasive outpatient treatments for female stress urinary incontinence (SUI) through a review of the literature. Methods. PubMed was searched for reports on prospective clinical trials with at least 12-month follow-up of minimally invasive treatments, pelvic floor rehabilitation, or pharmacotherapy in women with SUI. Each report was examined for long-term rates of effectiveness and safety. Results. Thirty-two clinical trial reports were included. Prospective long-term studies of pelvic floor rehabilitation were limited but indicated significant improvements with treatment adherence for at least 12 months. Poor initial tolerability with duloxetine resulted in substantial discontinuation. Most patients receiving transurethral radiofrequency collagen denaturation or urethral bulking agents reported significant long-term improvements, generally good tolerability, and safety. Conclusions. Conservative therapy is an appropriate initial approach for female SUI, but if therapy fails, radiofrequency collagen denaturation or bulking agents may be an attractive intermediate management step or alternative to surgery. PMID:21738529
Flight service evaluation of composite helicopter components
NASA Technical Reports Server (NTRS)
Mardoian, George H.; Ezzo, Maureen B.
1994-01-01
This paper presents the results of a NASA funded contract and Sikorsky research and development programs to evaluate structural composite components in flight service on Sikorsky Model S-76 helicopters. Selected components were removed and tested at prescribed intervals over a nine year time frame. Four horizontal stabilizers and thirteen tail rotor spars were returned from commercial service in West Palm Beach, Florida and in the Gulf Coast region of Louisiana to determine the long term effects of operations in hot and humid climates on component performance. Concurrent with the flight component evaluation, panels of materials used in their fabrication were exposed to the environment in ground racks. Selected panels were tested annually to determine the effects of exposure on physical and mechanical properties. The results of 55,741 component flight hours and 911 months of field exposure are reported and compared with initial Federal Aviation Administration (FAA) certification data. The findings of this program have provided increased confidence in the long term durability of advanced composite materials used in helicopter structural applications.
Key Durability Issues with Mullite-Based Environmental Barrier Coatings for Si-Based Ceramics
NASA Technical Reports Server (NTRS)
Lee, Kang N.
1999-01-01
Plasma-sprayed mullite (3Al2O3 central dot 2SiO2) and mullite/yttria-stabilized-zirconia (YSZ) dual layer coatings have been developed to protect silicon-based ceramics from environmental attack. Mullite-based coating systems show excellent durability in air. However, in combustion environments, corrosive species such as molten salt or water vapor penetrate through cracks in the coating and attack the Si-based ceramics along the interface, Thus modification of the coating system for enhanced crack-resistance is necessary for long-term durability in combustion environments. Other key durability issues include interfacial contamination and coating/substrate bonding. Interfacial contamination leads to enhanced oxidation and interfacial pore formation, while weak coating/substrate bonding leads to rapid attack of the interface by corrosive species, both of which can cause premature failure of the coating. Interfacial contamination can be minimized by limiting impurities in coating and substrate materials. The interface may be modified to improve the coating/substrate bond.
Key Durability Issues with Mullite-Based Environmental Barrier Coatings for Si-Based Ceramics
NASA Technical Reports Server (NTRS)
Lee, Kang N.
2000-01-01
Plasma-sprayed mullite (3Al2O3.2SiO2) and mullite/yttria-stabilized-zirconia (YSZ) dual layer coatings have been developed to protect silicon -based ceramics from environmental attack. Mullite-based coating systems show excellent durability in air. However, in combustion environments, corrosive species such as molten salt or water vapor penetrate through cracks in the coating and attack the Si-based ceramics along the interface. Thus the modification of the coating system for enhanced crack-resistance is necessary for long-term durability in combustion environments. Other key durability issues include interfacial contamination and coating/substrate bonding. Interfacial contamination leads to enhanced oxidation and interfacial pore formation, while a weak coating/substrate bonding leads to rapid attack of the interface by corrosive species, both of which can cause a premature failure of the coating. Interfacial contamination can be minimized by limiting impurities in coating and substrate materials. The interface may be modified to improve the coating/substrate bond.
A new kind of high durable traffic weighbridge based on FBG sensors
NASA Astrophysics Data System (ADS)
Zhou, Zhi; Liu, Jing; Li, Hui; Ou, Jinping
2005-05-01
Durability is the key problem of traditional traffic weighbridge based on electrical gauges. In this paper, a new kind of high durable traffic weighbridge based on FBG (Fiber Bragg Grating) sensors has been studied and developed. The principle of the smart FBG-weighbridge is based on that the traffic weight can be gotten from the deformation of the reinforced concrete beam with embedded FRP (Fiber Reinforced Polymer) - packaged FBG strain sensors. The FBG-based weighbridge is designed to be a reinforced concrete board supported by composite beams, and the truck load is shared by the composite beams. A 30-ton full scale FBG-based weighbridge has been set up, and the results from the tests and calibration analysis show that this kind of weighbridge features high durability, simplicity, convenience, low cost, etc. This new kind of FBG-based weighbridge shows good prospect in future to replace the traditional traffic weighbridge for long-term monitoring of traffic load.
NASA Astrophysics Data System (ADS)
Vomero, Maria
The aim of this work is to fabricate and characterize glassy carbon Microelectrode Arrays (MEAs) for sensing and stimulating neural activity, and conduct histological analysis of the brain tissue after the implant to determine long-term performance. Neural applications often require robust electrical and electrochemical response over a long period of time, and for those applications we propose to replace the commonly used noble metals like platinum, gold and iridium with glassy carbon. We submit that such material has the potential to improve the performances of traditional neural prostheses, thanks to better charge transfer capabilities and higher electrochemical stability. Great interest and attention is given in this work, in particular, to the investigation of tissue response after several weeks of implants in rodents' brain motor cortex and the associated materials degradation. As part of this work, a new set of devices for Electrocorticography (ECoG) has been designed and fabricated to improve durability and quality of the previous generation of devices, designed and manufactured by the same research group in 2014. In-vivo long-term impedance measurements and brain activity recordings were performed to test the functionality of the neural devices. In-vitro electrical characterization of the carbon electrodes, as well as the study of the adhesion mechanisms between glassy carbon and different substrates is also part of the research described in this book.
Polimenakos, Anastasios C; Sathanandam, Shyam; Elzein, Chawki; Barth, Mary J; Higgins, Robert S D; Ilbawi, Michel N
2010-04-01
Aortic cusp extension valvuloplasty is increasingly used in the management of children and adolescents with aortic stenosis or regurgitation. The durability of this approach and the freedom from valve replacement are not well defined. A study was undertaken to investigate outcomes. From July 1987 to November 2008, 142 patients aged less than 19 years underwent aortic cusp extension valvuloplasty in the form of pericardial cusp extension and tricuspidization (when needed). Three patients with truncus arteriosus and severe truncal valve insufficiency were excluded. From the available follow-up data of 139 patients, 50 had bicuspid aortic valves, 40 had congenital aortic valve stenosis, 41 had combined congenital aortic valve stenosis/insufficiency, and 8 had other diagnoses. Median follow-up was 14.4 years (0.1-21.4). Long-term mortality and freedom from aortic valve replacement were studied. There were no early, intermediate, or late deaths. Z-values of left ventricular end-diastolic dimension, aortic annulus, aortic sinus diameter, and sinotubular junction diameter before aortic valve replacement were 4.2 +/- 3.11, 2.3 +/- 1.25, 4.4 +/- 1.23, and 1.84 +/- 1.28, respectively. During the follow-up period, 64 patients underwent aortic valve reinterventions. The Ross procedure was performed in 32 of 139 patients (23%) undergoing aortic cusp extension valvuloplasty. Other aortic valve replacements were undertaken after 16 aortic cusp extension valvuloplasties (11.5%). Freedom from a second aortic cusp extension valvuloplasty or aortic valve replacement at 18 years was 82.1% +/- 4.2% and 60.0% +/- 7.2%, respectively. Aortic cusp extension valvuloplasty is a safe and effective surgical option with excellent survival and good long-term outcomes in children and adolescents. The procedure provides acceptable durability and satisfactory freedom from aortic valve replacement. Copyright 2010 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Shinn, Sung Ho; Dayan, Victor; Schaff, Hartzell V; Dearani, Joseph A; Joyce, Lyle D; Lahr, Brian; Greason, Kevin L; Stulak, John M; Daly, Richard C
2016-08-01
There is controversy regarding the comparative effectiveness of methods of tricuspid valve (TV) repair-prosthetic ring versus suture annuloplasty-in patients undergoing operation for primary mitral valve (MV) disease. In this study, we analyzed factors associated with patient survival and recurrent tricuspid regurgitation (TR) following TV repair and focused on results stratified by method of tricuspid valve repair. We reviewed patients who underwent TV repair with suture (De Vega) or flexible ring annuloplasties at the time of MV surgery from 1995 to 2010. Patients with prior cardiac or concomitant aortic valve operations were excluded. Propensity matching was performed to account for potential differences in baseline characteristics between the groups. Primary outcomes were long-term mortality and postoperative TR grade. In the overall study, there were 415 patients with median age 72 years (range, 63-78 years), from which 148 matched pairs were identified by propensity score analysis. In the overall cohort, patients in the ring annuloplasty group more often had preoperative transvenous pacemakers (P = .05), lower ejection fractions (P = .028), and more recent years of operation (P < .001). For patients who had De Vega suture annuloplasty, long-term mortality was not different from that of patients who had ring annuloplasty (hazard ratio, 0.93; 95% confidence interval, 0.67-1.30). Older age, preoperative diabetes, and preoperative right ventricular dysfunction were predictors for long-term mortality. Durability of the annuloplasty methods was similar with no significant difference in trend of recurrent TR grades over follow-up (P = .807). Etiology of mitral regurgitation was not associated with recurrent TR during follow-up (P = .857). Late survival and TV durability following concomitant TV repair during MV surgery did not differ with respect to TV repair technique. In this series of patients with repaired tricuspid valves, etiology of MV disease did not influence postoperative changes in TR. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Barkatt, A.; Boulos, M. S.; Barkatt, A.; Sousanpour, W.; Boroomand, M. A.; Macedo, P. B.; Okeefe, J. A.
1984-01-01
Leach tests carried out on tektite specimens (indochinites and australites) under high-dilution conditions show a common behavior characterized by low leach rates (0.00018 g/sq m per d, or 7.2 x 10 to the -12th m/d at 23 C) and an activation energy of (79,600 + or - 700 J/mol). The extent of selective leaching is very small, of the order of 10 to the -8th m. Extrapolation of test results over the lifetime of the tektites gives an excellent agreement with field observations on the extent of corrosion, and this is an important step in establishing the validity of laboratory tests as a basis for the development of models and predictions concerning long-term durabilities at least in the limiting case of high dilution or rapid flow. The results are also shown to be in agreement with various previous observations on the corrosion resistance of tektites. The chemical durability of tektites is observed to be consistent with their composition, highlighting requirements of high corrosion resistance in glasses; these requirements include a silica content in excess of 67 mol percent, an extremely low water content, and an alkali content which is low both absolutely and relative to the di- and poly-valent metal oxide levels. It is shown that artificial glasses which fulfil these criteria are no less corrosion-resistant than the corresponding natural glasses. These conclusions have bearing on the development, as well as on the evaluation, of glasses intended for very long service, such as radioactive waste vitrification media.
Mid-urethral slings in female incontinence: Current status
Krlin, Ryan M.; Murphy, Alana M.; Ingber, Michael S.; Vasavada, Sandip P.
2011-01-01
The advent of the mid-urethral sling (MUS) 15 years ago has drastically changed the surgical management of stress urinary incontinence (SUI). Both retropubic and transobturator MUS can be placed in the ambulatory setting with excellent results. The tension-free vaginal tape (TVT) sling has the most robust and long-term data, but more recent literature suggests that the transobturator tape sling may offer comparable efficacy in appropriately selected patients. Single incision sling (SIS) is the newest addition to the MUS group and was developed in an attempt to minimize morbidity and create an anti-incontinence procedure that could be performed in the office. The efficacy of SIS remains unknown as the current literature regarding SIS lacks long-term results and comparative trials. The suprapubic arc sling appears to have equally effective outcomes in at least the short-term when compared with TVT. Although evolution of the SIS has led to a less invasive procedure with decreased post-op pain and reduced recovery time, durability of efficacy could be the endpoint we are sacrificing. Until longer-term data and more quality comparison trials are available, tailoring one's choice of MUS to the individual patient and her unique clinical parameters remains the best option. PMID:22022053
Vlachojannis, Georgios J; Smits, Pieter C; Hofma, Sjoerd H; Togni, Mario; Vázquez, Nicolás; Valdés, Mariano; Voudris, Vassilis; Puricel, Serban; Slagboom, Ton; Goy, Jean-Jacques; den Heijer, Peter; van der Ent, Martin
2015-07-01
The aim of this analysis was to compare the long-term safety and efficacy of the biodegradable polymer biolimus-eluting stent (BES) with that of the durable polymer everolimus-eluting stent (EES). The COMPARE II study was a prospective, randomised, multicentre, all-comers trial in which 2,707 patients were randomly allocated (2:1) to BES or EES. The pre-specified endpoint at three years was major adverse cardiac events (MACE), a composite of cardiac death, non-fatal myocardial infarction (MI), or target vessel revascularisation (TVR). Moreover, the combined endpoint all-cause death or MI was analysed as a safety, and TVR as an efficacy measure. Three-year follow-up was available in 2,683 patients (99.1%). At three years, MACE occurred in 213 patients (11.9%) in the BES group and in 101 patients (11.1 %) in the EES group (p=0.57). The rate of the combined safety endpoint all-cause death or MI was 9.3% in the BES group vs. 8.4% (p=0.52), while the efficacy measure TVR was 7.6% in BES vs. 6.5% (p=0.27). Interestingly, definite stent thrombosis rates did not differ between groups (1.2% for BES vs. 0.8%, p=0.33). At three-year follow-up, MACE as well as safety and efficacy measures including stent thrombosis were not statistically different between the biodegradable polymer-coated BES and the durable polymer-coated EES. ClinicalTrials.gov Identifier: NCT01233453.
Long-term Durability of Immune Responses After Hepatitis A Vaccination Among HIV-Infected Adults
Wilkins, Kenneth; Lee, Andrew W.; Grosso, Anthony; Landrum, Michael L.; Weintrob, Amy; Ganesan, Anuradha; Maguire, Jason; Klopfer, Stephanie; Brandt, Carolyn; Bradley, William P.; Wallace, Mark R.; Agan, Brian K.
2011-01-01
Background. Vaccination provides long-term immunity to hepatitis A virus (HAV) among the general population, but there are no such data regarding vaccine durability among human immunodeficiency virus (HIV)–infected adults. Methods. We retrospectively studied HIV-infected adults who had received 2 doses of HAV vaccine. We analyzed blood specimens taken at 1 year, 3 years, and, when available, 6–10 years postvaccination. HAV immunoglobulin G (IgG) values of ≥10 mIU/mL were considered seropositive. Results. We evaluated specimens from 130 HIV-infected adults with a median age of 35 years and a median CD4 cell count of 461 cells/mm3 at or before time of vaccination. Of these, 49% had an HIV RNA load <1000 copies/mL. Initial vaccine responses were achieved in 89% of HIV-infected adults (95% confidence interval [CI], 83%–94%), compared with 100% (95% CI, 99%–100%) of historical HIV-uninfected adults. Among initial HIV-infected responders with available specimens, 90% (104 of 116; 95% CI, 83%–95%) remained seropositive at 3 years and 85% (63 of 74; 95% CI, 75%–92%) at 6–10 years. Geometric mean concentrations (GMCs) among HIV-infected adults were 154, 111, and 64 mIU/mL at 1, 3, and 6–10 years, respectively, compared with 1734, 687, and 684 mIU/mL among HIV-uninfected persons. Higher GMCs over time among HIV-infected adults were associated with lower log10 HIV RNA levels (β = −.12, P = .04). Conclusions. Most adults with well-controlled HIV infections had durable seropositive responses up to 6–10 years after HAV vaccination. Suppressed HIV RNA levels are associated with durable HAV responses. PMID:21606540
Ancient Glass: A Literature Search and its Role in Waste Management
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strachan, Denis M.; Pierce, Eric M.
2010-07-01
When developing a performance assessment model for the long-term disposal of immobilized low-activity waste (ILAW) glass, it is desirable to determine the durability of glass forms over very long periods of time. However, testing is limited to short time spans, so experiments are performed under conditions that accelerate the key geochemical processes that control weathering. Verification that models currently being used can reliably calculate the long term behavior ILAW glass is a key component of the overall PA strategy. Therefore, Pacific Northwest National Laboratory was contracted by Washington River Protection Solutions, LLC to evaluate alternative strategies that can be usedmore » for PA source term model validation. One viable alternative strategy is the use of independent experimental data from archaeological studies of ancient or natural glass contained in the literature. These results represent a potential independent experiment that date back to approximately 3600 years ago or 1600 before the current era (bce) in the case of ancient glass and 106 years or older in the case of natural glass. The results of this literature review suggest that additional experimental data may be needed before the result from archaeological studies can be used as a tool for model validation of glass weathering and more specifically disposal facility performance. This is largely because none of the existing data set contains all of the information required to conduct PA source term calculations. For example, in many cases the sediments surrounding the glass was not collected and analyzed; therefore having the data required to compare computer simulations of concentration flux is not possible. This type of information is important to understanding the element release profile from the glass to the surrounding environment and provides a metric that can be used to calibrate source term models. Although useful, the available literature sources do not contain the required information needed to simulate the long-term performance of nuclear waste glasses in a near-surface or deep geologic repositories. The information that will be required include 1) experimental measurements to quantify the model parameters, 2) detailed analyses of altered glass samples, and 3) detailed analyses of the sediment surrounding the ancient glass samples.« less
Durability Testing of Biomass Based Oxygenated Fuel Components in a Compression Ignition Engine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ratcliff, Matthew A; McCormick, Robert L; Baumgardner, Marc E.
Blending cellulosic biofuels with traditional petroleum-derived fuels results in transportation fuels with reduced carbon footprints. Many cellulosic fuels rely on processing methods that produce mixtures of oxygenates which must be upgraded before blending with traditional fuels. Complete oxygenate removal is energy-intensive and it is likely that such biofuel blends will necessarily contain some oxygen content to be economically viable. Previous work by our group indicated that diesel fuel blends with low levels (<4%-vol) of oxygenates resulted in minimal negative effects on short-term engine performance and emissions. However, little is known about the long-term effects of these compounds on engine durabilitymore » issues such as the impact on fuel injection, in-cylinder carbon buildup, and engine oil degradation. In this study, four of the oxygenated components previously tested were blended at 4%-vol in diesel fuel and tested with a durability protocol devised for this work consisting of 200 hrs of testing in a stationary, single-cylinder, Yanmar diesel engine operating at constant load. Oil samples, injector spray patterns, and carbon buildup from the injector and cylinder surfaces were analyzed. It was found that, at the levels tested, these fuels had minimal impact on the overall engine operation, which is consistent with our previous findings.« less
Corrosion performance of zinc coated steel in seawater environment
NASA Astrophysics Data System (ADS)
Liu, Shuan; Zhao, Xia; Zhao, Haichao; Sun, Huyuan; Chen, Jianmin
2017-03-01
Considering the continuous exploitation of marine resources, it is very important to study the anticorrosion performance and durability of zinc coated streel (ZCS) because its increasing use as reinforcements in seawater. Tafel polarization curves and linear polarization curves combined with electrochemical impedance spectroscopy (EIS) were employed to evaluate the corrosion performance of ZCS at Qingdao test station during long-term immersion in seawater. The results indicated that the corrosion rate of the ZCS increased obviously with immersion time in seawater. The corrosion products that formed on the zinc coated steel were loose and porous, and were mainly composed of Zn5(OH)8Cl2, Zn5(OH)6(CO3)2, and ZnO. Pitting corrosion occurred on the steel surface in neutral seawater, and the rate of ZCS corrosion decreased with increasing pH.
Roche, Benjamin; Drake, John M.; Brown, Justin; Stallknecht, David E.; Bedford, Trevor; Rohani, Pejman
2014-01-01
Avian influenza viruses (AIVs) have been pivotal to the origination of human pandemic strains. Despite their scientific and public health significance, however, there remains much to be understood about the ecology and evolution of AIVs in wild birds, where major pools of genetic diversity are generated and maintained. Here, we present comparative phylodynamic analyses of human and AIVs in North America, demonstrating (i) significantly higher standing genetic diversity and (ii) phylogenetic trees with a weaker signature of immune escape in AIVs than in human viruses. To explain these differences, we performed statistical analyses to quantify the relative contribution of several potential explanations. We found that HA genetic diversity in avian viruses is determined by a combination of factors, predominantly subtype-specific differences in host immune selective pressure and the ecology of transmission (in particular, the durability of subtypes in aquatic environments). Extending this analysis using a computational model demonstrated that virus durability may lead to long-term, indirect chains of transmission that, when coupled with a short host lifespan, can generate and maintain the observed high levels of genetic diversity. Further evidence in support of this novel finding was found by demonstrating an association between subtype-specific environmental durability and predicted phylogenetic signatures: genetic diversity, variation in phylogenetic tree branch lengths, and tree height. The conclusion that environmental transmission plays an important role in the evolutionary biology of avian influenza viruses—a manifestation of the “storage effect”—highlights the potentially unpredictable impact of wildlife reservoirs for future human pandemics and the need for improved understanding of the natural ecology of these viruses. PMID:25116957
Sachs, Donald; Kovalsky, Don; Redmond, Andy; Limoni, Robert; Meyer, S Craig; Harvey, Charles; Kondrashov, Dimitriy
2016-01-01
Background Sacroiliac joint (SIJ) fusion (SIJF), first performed 95 years ago, has become an increasingly accepted surgical option for chronic SIJ dysfunction. Few studies have reported intermediate- or long-term outcomes after SIJF. Objective The objective of this study is to determine patient-based outcomes after SIJF for chronic SIJ dysfunction due to degenerative sacroiliitis or SIJ disruption at ≥3 years of follow-up. Methods Consecutive patients who underwent SIJF prior to December 2012 were contacted over phone or through email. Participants completed questionnaires in clinic, over phone or by email, regarding SIJ pain, activities related to SIJ dysfunction, and the Oswestry Disability Index. Charts were reviewed to extract baseline parameters and the clinical course of follow-up. Results One hundred seven patients were eligible and participated in this study. Mean (standard deviation) preoperative SIJ pain score was 7.5 (1.7). At mean follow-up of 3.7 years, the mean SIJ pain score was 2.6 (representing a 4.8-point improvement from baseline, P<0.0001) and the mean Oswestry Disability Index was 28.2. The ability to perform activities commonly impaired by SIJ dysfunction showed positive improvements in most patients. SIJ revision surgery was uncommon (five patients, 4.7%). Fourteen patients (13.1%) underwent contralateral SIJF during follow-up, 25.2% of patients had additional non-SIJ-related lumbar spine or hip surgeries during follow-up. Conclusion In intermediate- to long-term follow-up, minimally invasive transiliac SIJF was associated with improved pain, low disability scores, and improved ability to perform activities of daily living. PMID:27471413
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gangwal, S.K.; Gupta, R.P.; Khare, G.P.
The objectives of this project are to determine the long-term chemical reactivity and mechanical durability of a fluidized version of Phillips Petroleum Company`s proprietary Z-SORB sorbent for the desulfurization of coal-derived gases in a high-pressure (20 atm) fluidized-bed reactor under simulated U-Gas conditions and at a moderate operating temperature of 538 degrees C.
Deborah F. Cook; Philip A. Araman; Matthew F. Winn
2000-01-01
A computerized pallet grading training system was developed to facilitate the production of higher quality pallets. Higher quality pallets would be more durable and could be re-used many times, resulting in long-term savings. Schmoldt et al. (1993) evaluated the economic impact of grading and sorting pallet parts. They determined that higher quality pallets produced by...
ERIC Educational Resources Information Center
Ludman, Evette J.; Simon, Gregory E.; Tutty, Steve; Von Korff, Michael
2007-01-01
Randomized trial evidence and expert guidelines are mixed regarding the value of combined pharmacotherapy and psychotherapy as initial treatment for depression. This study describes long-term results of a randomized trial (N = 393) evaluating telephone-based cognitive-behavioral therapy (CBT) plus care management for primary care patients…
ERIC Educational Resources Information Center
Luczynski, Kevin C.; Hanley, Gregory P.; Rodriguez, Nicole M.
2014-01-01
The preschool life skills (PLS) program (Hanley, Heal, Tiger, & Ingvarsson, 2007; Luczynski & Hanley, 2013) involves teaching social skills as a means of decreasing and preventing problem behavior. However, achieving durable outcomes as children transition across educational settings depend on the generalization and long-term maintenance…
Effect of Prior Aging on Fatigue Behavior of IM7/BMI 5250-4 Composite at 191 C
2007-06-01
6 Figure 4. Three stages of fatigue life cycle for general material ....................................... 9 Figure 5...calibration ........ 24 vii Figure 17. Omega thermocouple reader setup .................................................................. 26 Figure...cost and fleet readiness. To assure long- term durability and structural integrity of HTPMC components, reliable experimentally- based life -prediction
De Bonis, Michele; Lapenna, Elisabetta; Del Forno, Benedetto; Di Sanzo, Stefania; Giacomini, Andrea; Schiavi, Davide; Vicentini, Luca; Latib, Azeem; Pozzoli, Alberto; Pappalardo, Federico; La Canna, Giovanni; Alfieri, Ottavio
2017-07-01
To evaluate whether the adoption of a right minithoracotomy operative approach had an impact on the long-term results of edge-to-edge (EE) repair compared to conventional sternotomy in patients with Barlow's disease and bileaflet prolapse. We assessed the long-term results of 104 patients with Barlow's disease treated with a minimally invasive EE technique. An equal number of patients had a conventional median sternotomy EE repair for the same disease and were used as a control group. The inverse probability of treatment weighting was used to create comparable distributions of the covariates that were significantly different at baseline in the two groups. We performed a comparative analysis of the groups. No hospital deaths were observed. Follow-up was 99.5% complete (median 11.3 years). The cumulative incidence function (CIF) of cardiac death at 12 years, with noncardiac death as a competing risk, showed no difference between the two groups ( P = 0.87). At 12 years, the CIF of recurrent MR ≥ 3+, with death as the competing risk, was 7% in the sternotomy group and 5% in the minimally invasive group ( P = 0.30), and the CIF of recurrence of MR ≥ 2+ was 15 and 14%, respectively ( P = 0.63). The type of surgical approach was not a predictor of cardiac death, reoperation, recurrent MR ≥ 3+ or recurrent MR ≥ 2+. A minimally invasive approach does not have a negative impact on the effectiveness and long-term durability of the EE repair for bileaflet prolapse in Barlow's disease. Long-term outcomes are excellent, and valvular performance remains stable over time with no evidence of mitral stenosis. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
High-Fidelity Visual Long-Term Memory within an Unattended Blink of an Eye.
Kuhbandner, Christof; Rosas-Corona, Elizabeth A; Spachtholz, Philipp
2017-01-01
What is stored in long-term memory from current sensations is a question that has attracted considerable interest. Over time, several prominent theories have consistently proposed that only attended sensory information leaves a durable memory trace whereas unattended information is not stored beyond the current moment, an assumption that seems to be supported by abundant empirical evidence. Here we show, by using a more sensitive memory test than in previous studies, that this is actually not true. Observers viewed a rapid stream of real-world object pictures overlapped by words (presentation duration per stimulus: 500 ms, interstimulus interval: 200 ms), with the instruction to attend to the words and detect word repetitions, without knowing that their memory would be tested later. In a surprise two-alternative forced-choice recognition test, memory for the unattended object pictures was tested. Memory performance was substantially above chance, even when detailed feature knowledge was necessary for correct recognition, even when tested 24 h later, and even although participants reported that they do not have any memories. These findings suggests that humans have the ability to store at high speed detailed copies of current visual stimulations in long-term memory independently of current intentions and the current attentional focus.
Opportunities and challenges for the biodegradable magnesium alloys as next-generation biomaterials
Ding, Wenjiang
2016-01-01
In recent years, biodegradable magnesium alloys emerge as a new class of biomaterials for tissue engineering and medical devices. Deploying biodegradable magnesium-based materials not only avoids a second surgical intervention for implant removal but also circumvents the long-term foreign body effect of permanent implants. However, these materials are often subjected to an uncontrolled and fast degradation, acute toxic responses and rapid structural failure presumably due to a localized, too rapid corrosion process. The patented Mg–Nd–Zn–based alloys (JiaoDa BioMg [JDBM]) have been developed in Shanghai Jiao Tong University in recent years. The alloy series exhibit lower biodegradation rate and homogeneous nanophasic degradation patterns as compared with other biodegradable Mg alloys. The in vitro cytotoxicity tests using various types of cells indicate excellent biocompatibility of JDBM. Finally, bone implants using JDBM-1 alloy and cardiovascular stents using JDBM-2 alloy have been successfully fabricated and in vivo long-term assessment via implantation in animal model have been performed. The results confirmed the reduced degradation rate in vivo, excellent tissue compatibility and long-term structural and mechanical durability. Thus, this novel Mg-alloy series with highly uniform nanophasic biodegradation represent a major breakthrough in the field and a promising candidate for manufacturing the next generation biodegradable implants. PMID:27047673
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suryavanshi, A.K.; Swamy, R.N.
1997-07-01
The long-term performance of a concrete slab (CPF slab) exposed to chloride ingress and atmospheric carbonation from the surface generated by controlled permeability formwork (CPF) is investigated. The results are compared with a similar slab exposed to long-term chloride ingress and atmospheric carbonation from the cast face (Control slab). Techniques such as X-ray diffraction (XRD) and differential thermal analyses (DTA) were employed to determine the resistance against carbonation while, mercury porosimetry was used for investigating the pore size distribution at the surface of the slabs. Amount of acid soluble chlorides was determined by using Volhard`s method. The CPF employed atmore » the bottom of the mould was not fully effective in its intended purpose of generating a permanent and dense impermeable concrete layer adjacent to it when the design water-cement (w/c) ration of the concrete mix was 0.60. This resulted in an almost similar extent of carbonation at the surface for both CPF and control slabs as shown by XRD and DTA studies. Similarly, there were no significant differences in the amount of chlorides and their depths of penetration for both CPF and control slabs, although the former was marginally superior in chloride penetration resistance at the surface.« less
Effect of Ni content on the morphological evolution of Ni-YSZ solid oxide fuel cell electrodes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen-Wiegart, Yu-chen Karen; Kennouche, David; Scott Cronin, J.
2016-02-22
The coarsening of Ni in Ni–yttria-stabilized zirconia (YSZ) anodes is a potential cause of long term solid oxide fuel cells (SOFC) performance degradation. The specifics of the Ni-YSZ structure—including Ni/YSZ ratio, porosity, and particle size distributions—are normally selected to minimize anode polarization resistance, but they also impact long-term stability. A better understanding of how these factors influence long-term stability is important for designing more durable anodes. The effect of structural details, e.g., Ni-YSZ ratio, on Ni coarsening has not been quantified. Furthermore, prior measurements have been done by comparing evolved structures with control samples, such that sample-to-sample variations introduce errors.more » Here, we report a four dimensional (three spatial dimensions and time) study of Ni coarsening in Ni-YSZ anode functional layers with different Ni/YSZ ratios, using synchrotron x-ray nano-tomography. The continuous structural evolution was observed and analyzed at sub-100 nm resolution. It is shown quantitatively that increasing the Ni/YSZ ratio increases the Ni coarsening rate. This is due to both increased pore volume and a decrease in the YSZ volume fraction, such that there is more free volume and a less obtrusive YSZ network, both of which allow greater Ni coarsening. The results are shown to be in good agreement with a power-law coarsening model. The finding is critical for informing the design of SOFC electrode microstructures that limit coarsening and performance degradation.« less
Effect of Ni content on the morphological evolution of Ni-YSZ solid oxide fuel cell electrodes
NASA Astrophysics Data System (ADS)
Chen-Wiegart, Yu-chen Karen; Kennouche, David; Scott Cronin, J.; Barnett, Scott A.; Wang, Jun
2016-02-01
The coarsening of Ni in Ni-yttria-stabilized zirconia (YSZ) anodes is a potential cause of long term solid oxide fuel cells (SOFC) performance degradation. The specifics of the Ni-YSZ structure—including Ni/YSZ ratio, porosity, and particle size distributions—are normally selected to minimize anode polarization resistance, but they also impact long-term stability. A better understanding of how these factors influence long-term stability is important for designing more durable anodes. The effect of structural details, e.g., Ni-YSZ ratio, on Ni coarsening has not been quantified. Furthermore, prior measurements have been done by comparing evolved structures with control samples, such that sample-to-sample variations introduce errors. Here, we report a four dimensional (three spatial dimensions and time) study of Ni coarsening in Ni-YSZ anode functional layers with different Ni/YSZ ratios, using synchrotron x-ray nano-tomography. The continuous structural evolution was observed and analyzed at sub-100 nm resolution. It is shown quantitatively that increasing the Ni/YSZ ratio increases the Ni coarsening rate. This is due to both increased pore volume and a decrease in the YSZ volume fraction, such that there is more free volume and a less obtrusive YSZ network, both of which allow greater Ni coarsening. The results are shown to be in good agreement with a power-law coarsening model. The finding is critical for informing the design of SOFC electrode microstructures that limit coarsening and performance degradation.
Kerkhoffs, Wolfgang; Schumacher, Oliver; Meyns, Bart; Verbeken, Erik; Leunens, Veerle; Bollen, Hilde; Reul, Helmut
2004-10-01
The design concept and first in vitro and in vivo results of a long-term implantable ventricular assist device system based on a microaxial blood pump are presented. The blood-immersed parts of the pump consist of a single-stage impeller and a proximally integrated microelectric motor. Both parts are surrounded by a pump housing currently made of polycarbonate to allow visible access to the blood-exposed parts. A titanium inflow cage attached to the tip of the housing is directly implanted into the left ventricular apex. The outflow of the pump is connected to the descending aorta by means of an e-PTFE graft. The overall dimensions of the device are 12 mm in outer diameter and about 50 mm in length. The calculated lifetime of the device is up to 2 years. The system underwent long-term durability tests, hydraulic performance tests, dynamic stability tests, and in vitro hemolysis and thrombogenicity tests. Furthermore, animal tests have been performed in adult Dorset sheep. In a first series, the pump has been placed extracorporeally; in a second series, the pump was completely implanted. Mean duration of the animal experiments of the second series was 31 days (range 8-110 days, n=14); no anticoagulation was administered over the whole test period. Blood data revealed no significant changes in blood cell counts, ionogram, or any other value. No end-organ dysfunction induced by long-term support could be observed, nor did the pathology reveal any evidence of thromboembolic complications.
NASA Astrophysics Data System (ADS)
Love, Corey T.
2011-03-01
Static and dynamic thermomechanical analysis was performed with a dynamic mechanical analyzer (DMA) to identify thermal and mechanical transitions for commercially available polymer separators under mechanical loading. Clear transitions in deformation mode were observed at elevated temperatures. These transitions identified the onset of separator "shutdown" which occurred at temperatures below the polymer melting point. Mechanical loading direction was critical to the overall integrity of the separator. Anisotropic separators (Celgard 2320, 2400 and 2500) were mechanically limited when pulled in tensile in the transverse direction. The anisotropy of these separators is a result of the dry technique used to manufacture the micro-porous membranes. Separators prepared using the wet technique (Entek Gold LP) behaved more uniformly, or biaxially, where all mechanical properties were nearly identical within the separator plane. The information provided by the DMA can also be useful for predicting the long-term durability of polymer separators in lithium-ion batteries exposed to electrolyte (solvent and salt), thermal fluctuations and electrochemical cycling. Small losses in mechanical integrity were observed for separators exposed to the various immersion environments over the 4-week immersion time.
Ultra-high performance concrete : a state-of-the-art report for the bridge community.
DOT National Transportation Integrated Search
2013-06-01
"The term Ultra-High Performance Concrete (UHPC) refers to a relatively new class of advanced cementitious : composite materials whose mechanical and durability properties far surpass those of conventional concrete. This : class of concrete has been ...
Goodwin, Scott C; Spies, James B; Worthington-Kirsch, Robert; Peterson, Eric; Pron, Gaylene; Li, Shuang; Myers, Evan R
2008-01-01
To assess long-term clinical outcomes of uterine artery embolization across a wide variety of practice settings in a large patient cohort. The Fibroid Registry for Outcomes Data (FIBROID) for Uterine Embolization was a 3-year, single-arm, prospective, multi-center longitudinal study of the short- and long-term outcomes of uterine artery embolization for leiomyomata. Two thousand one hundred twelve patients with symptomatic leiomyomata were eligible for long-term follow-up at 27 sites representing a geographically diverse set of practices, including academic centers, community hospitals, and closed-panel health maintenance organizations. At 36 months after treatment, 1,916 patients remained in the study, and of these, 1,278 patients completed the survey. The primary measures of outcome were the symptom and health-related quality-of-life scores from the Uterine Fibroid Symptom and Quality of Life questionnaire. Mean symptom scores improved 41.41 points (P<.001), and the quality of life scores improved 41.47 points (P<.001), both moving into the normal range for this questionnaire. The improvements were independent of practice setting. During the 3 years of the study, Kaplan-Meier estimates of hysterectomy, myomectomy, or repeat uterine artery embolization were 9.79%, 2.82%, and 1.83% of the patients, respectively. Uterine artery embolization results in a durable improvement in quality of life. These results are achievable when the procedure is performed in any experienced community or academic interventional radiology practice. III.
Cheung, Nicholas K; Chiu, Albert Hy; Cheung, Andrew; Wenderoth, Jason D
2018-06-01
Stent assisted coil embolization (SACE) of bifurcation aneurysms is challenging. Heterogeneous results have been achieved to date, but largely for laser cut stents. While braided stents offer multiple technical advantages, their long term efficacy has yet to be validated. To report the first long term 18 month results for the durability of bifurcation aneurysms treated with braided stents. Over a 4 year period, 59 consecutive patients with 60 bifurcation aneurysms underwent elective braided SACE across three Australian neurovascular centers. 17 of these aneurysms underwent T- or Y-shaped stent constructs. All patients had immediate, 6 month and 18 month clinical and radiological follow-up. Radiological assessment was made on modified Raymond-Roy occlusion scores while clinical assessment was based on the modified Rankin Scale. Subgroup analysis of 17 aneurysms treated with multi-stent constructs was conducted. 6 month follow-up data were available for 59 aneurysms and 18 month follow-up data for 58 aneurysms. Satisfactory aneurysm occlusion was achieved in 97% at inception and at 6 months, and 98% at 18 months. Good neurological outcomes were achieved in 95% at 18 months. Similar satisfactory results were achieved with the multi-stent construct cohort. Intraprocedural thromboembolic events were recorded in 5% and delayed events in 2%. Technical complications were found in 5%. All complication rate was 13%. Braided SACE was safe, efficacious, and durable at the long term 18 month follow-up, including for multi-stent constructs. Preliminary results indicate favorable clinical and radiological outcomes compared with laser cut stents. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
AMTEC cell testing, optimization of rhodium/tungsten electrodes, and tests of other components
NASA Technical Reports Server (NTRS)
Williams, Roger M.; Ryan, Margaret A.; Jeffries-Nakamura, Barbara; Underwood, Mark L.; O'Connor, Dennis; Kikkert, Stan
1991-01-01
Electrodes, current collectors, ceramic to metal braze seals, and metallic components exposed to the high 'hot side' temperatures and sodium liquid and vapor environment have been tested and evaluated in laboratory cells running for hundreds of hours at 1100-1200 K. Rhodium/tungsten electrodes have been selected as the optimum electrodes based on performance parameters and durability. Current collectors have been evaluated under simulated and actual operating conditions. The microscopic effects of metal migration between electrode and current collector alloys as well as their thermal and electrical properties determined the suitability of current collector and lead materials. Braze seals suitable for long term application to AMTEC devices are being developed.
The role of the Long Duration Exposure Facility in the development of space systems
NASA Technical Reports Server (NTRS)
Little, Sally A.
1992-01-01
The Long Duration Exposure Facility (LDEF) presents the international, aerospace community with an unprecedented opportunity to examine the synergistic, long term, space environmental effects on systems and materials. The analysis of the data within appropriate environmental contexts is essential to the overall process of advancing the understanding of space environmental effects needed for the continuing development of strategies to improve the reliability and durability of space systems and to effectively deal with the future challenges that new space initiatives will likely present.
Hygrothermal effects on durability and moisture kinetics of fiber-reinforced polymer composites.
DOT National Transportation Integrated Search
2006-06-01
Fiber-Reinforced Polymer (FRP) composites offer many advantages over conventional materials for : applications in the marine and civil infrastructure areas. Their increasing widespread use emphasizes the : need to predict their performance over long ...
Long-term evaluation of a nonpulsatile mechanical circulatory support system.
Wakisaka, Y; Taenaka, Y; Chikanari, K; Nakatani, T; Tatsumi, E; Masuzawa, T; Nishimura, T; Takewa, Y; Ohno, T; Takano, H
1997-07-01
Antithrombogenicity of a centrifugal pump (CP) developed in our institute is provided by a central balancing hole (BH) in the impeller. A current CP, the National Cardiovascular Center (NCVC)-2, was ameliorated to improve antithrombogenicity, whereby the BH diameter was widened to improve self washout flow velocity, and an edge of the thrust bearing was rounded off to minimize flow separation. Effects of these modifications were assessed in a long-term in vivo experiment. The antithrombogenicity, hemolytic property, and mechanical durability of the NCVC-2 were investigated in 3 goats. The NCVC-2 was installed paracorporeally between the left atrium and the aorta and driven as long as possible at rotating speeds of about 2,800 rpm. The NCVC-2 ran for 50, 200, and 367+ days. The mean bypass flow rates were 6.8, 5.0, and 5.3 L/min, respectively. Creatinine, blood urea nitrogen (BUN), glutamic-oxaloacetic transaminase (GOT), and glutamic-pyruvic transaminase (GPT) did not increase until one week before termination. Plasma free hemoglobin was kept to a level less than 15 mg/dl, except for the last week of the second case. These results indicate that the NCVC-2 has excellent antithrombogenicity, an acceptable hemolytic property and the necessary durability for prolonged use.
NASA Astrophysics Data System (ADS)
Zhao, Xia; Chen, Changwei; Xu, Weichen; Zhu, Qingjun; Ge, Chengyue; Hou, Baorong
2017-09-01
Defects in protective-coating systems on steel surfaces are inevitable in practical engineering applications. A composite coating system, including a primer, middle coat and topcoat, were used to protect carbon steel from corrosion in a marine environment. Two environmental additives, glass fibers and thiourea, were applied in the middle coat to modify the coating system. The long-term corrosion durability and self-healing ability of the scratched coating system were evaluated by multiple methods. Results of the electrochemical technologies indicated that the coating system that contained 0.5 wt.% fibers and 0.5 wt.% thiourea presented good corrosion protection and self-healing for carbon steel when immersed in 3.5% NaCl for 120 d. Evolution of localized corrosion factors with time, as obtained from the current distribution showed that fibers combined with thiourea could inhibit the occurrence of local corrosion in scratched coating systems and retarded the corrosion development significantly. Surface characterization suggested that adequate thiourea could be absorbed uniformly on fibers for a long time to play an important role in protecting the carbon steel. Finally, schematic models were established to demonstrate the action of fibers and thiourea on the exposed surface of the carbon steel and the scratched coating system in the entire deterioration process.
Fatigue behaviour analysis for the durability prequalification of strengthening mortars
NASA Astrophysics Data System (ADS)
Bocca, P.; Grazzini, A.; Masera, D.
2011-07-01
An innovative laboratory procedure used as a preliminary design stage for the pre-qualification of strengthening mortars applied to historical masonry buildings is described. In the analysis of the behaviour of masonry structures and their constituent materials, increasing importance has been assumed by the study of the long-term evolution of deformation and mechanical characteristics, which may be affected by both loading and environmental conditions. Through static and fatigue tests on mixed specimens historical brick-reinforced mortar it has been possible to investigate the durability of strengthening materials, in order to select, from a range of alternatives, the most suitable for the historical masonry. Cyclic fatigue stress has been applied to accelerate the static creep and to forecast the corresponding creep behaviour of the historical brick-strengthening mortar system under static long-time loading. This methodology has proved useful in avoiding the errors associated with materials that are not mechanically compatible and guarantees the durability of strengthening work. The experimental procedure has been used effectively in the biggest restoration building site in Europe, the Royal Palace of Venaria, and it is in progress of carrying out at the Special Natural Reserve of the Sacro Monte di Varallo, in Piedmont (Italy).
Urbanization, regime type and durability, and environmental degradation in Ghana.
Adams, Samuel; Adom, Philip Kofi; Klobodu, Edem Kwame Mensah
2016-12-01
This study examines the effect of urbanization, income, trade openness, and institutional quality (i.e., regime type and durability) on environmental degradation in Ghana over the period 1965-2011. Using the bounds test approach to cointegration and the Fully Modified Phillip-Hansen (FMPH) technique, the findings show that urbanization, income, trade openness, and institutional quality have long-run cointegration with environmental degradation. Further, the results show that income, trade openness, and institutional quality are negatively associated with environmental degradation. This suggests that income, trade openness, and institutional quality enhance environmental performance. Urbanization, however, is positively related to environmental degradation. Additionally, long-run estimates conditioned on institutional quality reveal that the extent to which trade openness and urbanization enhance environmental performance is largely due to the presence of quality institutions (or democratic institutions). Finally, controlling for structural breaks, we find that trade openness, urbanization, and regime type (i.e., democracy) improve environmental performance significantly after the 1970s except for income.
Quenouille, J; Paulhiac, E; Moury, B; Palloix, A
2014-06-01
The combination of major resistance genes with quantitative resistance factors is hypothesized as a promising breeding strategy to preserve the durability of resistant cultivar, as recently observed in different pathosystems. Using the pepper (Capsicum annuum)/Potato virus Y (PVY, genus Potyvirus) pathosystem, we aimed at identifying plant genetic factors directly affecting the frequency of virus adaptation to the major resistance gene pvr2(3) and at comparing them with genetic factors affecting quantitative resistance. The resistance breakdown frequency was a highly heritable trait (h(2)=0.87). Four loci including additive quantitative trait loci (QTLs) and epistatic interactions explained together 70% of the variance of pvr2(3) breakdown frequency. Three of the four QTLs controlling pvr2(3) breakdown frequency were also involved in quantitative resistance, strongly suggesting that QTLs controlling quantitative resistance have a pleiotropic effect on the durability of the major resistance gene. With the first mapping of QTLs directly affecting resistance durability, this study provides a rationale for sustainable resistance breeding. Surprisingly, a genetic trade-off was observed between the durability of PVY resistance controlled by pvr2(3) and the spectrum of the resistance against different potyviruses. This trade-off seemed to have been resolved by the combination of minor-effect durability QTLs under long-term farmer selection.
Highly Durable Na2V6O16·1.63H2O Nanowire Cathode for Aqueous Zinc-Ion Battery.
Hu, Ping; Zhu, Ting; Wang, Xuanpeng; Wei, Xiujuan; Yan, Mengyu; Li, Jiantao; Luo, Wen; Yang, Wei; Zhang, Wencui; Zhou, Liang; Zhou, Zhiqiang; Mai, Liqiang
2018-03-14
Rechargeable aqueous zinc-ion batteries are highly desirable for grid-scale applications due to their low cost and high safety; however, the poor cycling stability hinders their widespread application. Herein, a highly durable zinc-ion battery system with a Na 2 V 6 O 16 ·1.63H 2 O nanowire cathode and an aqueous Zn(CF 3 SO 3 ) 2 electrolyte has been developed. The Na 2 V 6 O 16 ·1.63H 2 O nanowires deliver a high specific capacity of 352 mAh g -1 at 50 mA g -1 and exhibit a capacity retention of 90% over 6000 cycles at 5000 mA g -1 , which represents the best cycling performance compared with all previous reports. In contrast, the NaV 3 O 8 nanowires maintain only 17% of the initial capacity after 4000 cycles at 5000 mA g -1 . A single-nanowire-based zinc-ion battery is assembled, which reveals the intrinsic Zn 2+ storage mechanism at nanoscale. The remarkable electrochemical performance especially the long-term cycling stability makes Na 2 V 6 O 16 ·1.63H 2 O a promising cathode for a low-cost and safe aqueous zinc-ion battery.
Chapter 14: Evaluating the Leaching of Biocides from Preservative-Treated Wood Products
Stan T. Lebow
2014-01-01
Leaching of biocides is an important consideration in the long term durability and any potential for environmental impact of treated wood products. This chapter discusses factors affecting biocide leaching, as well as methods of evaluating rate and quantity of biocide released. The extent of leaching is a function of preservative formulation, treatment methods, wood...
NREL Scientists Demonstrate Remarkable Stability in Perovskite Solar Cells
environmentally stable, high-efficiency perovskite solar cell, bringing the emerging technology a step closer to needed to make the devices durable enough for long-term use. NREL's unencapsulated solar cell-a cell used Unencapsulated Perovskite Solar Cells for >1000 Hours of Operational Stability." "A solar cell in
Long term durability of wood-plastic composites made with chemically modified wood
Rebecca E. Ibach; Craig M. Clemons
2017-01-01
Wood-plastic composites (WPCs) have slower moisture sorption than solid wood, but over time moisture can impact the strength, stiffness, and decay of the composite. These changes will become increasingly important if WPCs are used in more challenging environments such as in ground-contact applications. There are several options for mitigating the moisture sorption of...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goldberg, Louise F.; Harmon, Anna C.
2015-04-09
This project was funded jointly by the National Renewable Energy Laboratory (NREL) and Oak Ridge National Laboratory (ORNL). ORNL focused on developing a full basement wall system experimental database to enable others to validate hygrothermal simulation codes. NREL focused on testing the moisture durability of practical basement wall interior insulation retrofit solutions for cold climates. The project has produced a physically credible and reliable long-term hygrothermal performance database for retrofit foundation wall insulation systems in zone 6 and 7 climates that are fully compliant with the performance criteria in the 2009 Minnesota Energy Code. These data currently span the periodmore » from November 10, 2012 through May 31, 2014 and are anticipated to be extended through November 2014. The experimental data were configured into a standard format that can be published online and that is compatible with standard commercially available spreadsheet and database software.« less
A magnetic fluid seal for rotary blood pumps: Long-term performance in liquid
NASA Astrophysics Data System (ADS)
Mitamura, Yoshinori; Takahashi, Sayaka; Amari, Shuichi; Okamoto, Eiji; Murabayashi, Shun; Nishimura, Ikuya
A magnetic fluid (MF) seal enables mechanical contact-free rotation of the shaft and hence has excellent durability. The performance of a MF seal, however, has been reported to decrease in liquids. We have developed a MF seal that has a 'shield' mechanism and a new MF with a higher magnetization of 47.9 kA/m. The sealing performance of the MF seal installed in a rotary blood pump was studied. The seal was perfect against a pressure of 150 mmHg in a continuous flow of 4.0 L/min for 275 days and against a pressure of 175 mmHg in a continuous flow of 3.9 L/min for 217 days. We have developed a MF seal that works in liquid against pressure mostly used clinically. The magnetic fluid seal is promising as a shaft seal for rotary blood pumps.
Incidental biasing of attention from visual long-term memory.
Fan, Judith E; Turk-Browne, Nicholas B
2016-06-01
Holding recently experienced information in mind can help us achieve our current goals. However, such immediate and direct forms of guidance from working memory are less helpful over extended delays or when other related information in long-term memory is useful for reaching these goals. Here we show that information that was encoded in the past but is no longer present or relevant to the task also guides attention. We examined this by associating multiple unique features with novel shapes in visual long-term memory (VLTM), and subsequently testing how memories for these objects biased the deployment of attention. In Experiment 1, VLTM for associated features guided visual search for the shapes, even when these features had never been task-relevant. In Experiment 2, associated features captured attention when presented in isolation during a secondary task that was completely unrelated to the shapes. These findings suggest that long-term memory enables a durable and automatic type of memory-based attentional control. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
NASA Technical Reports Server (NTRS)
Rojdev, Kristina; Graves, Russell; Golden, John; Atwell, William; O'Rouke, Mary Jane; Hill, Charles; Alred, John
2011-01-01
NASA's exploration goals include extending human presence beyond low earth orbit (LEO). As a result, habitation for crew is a critical requirement for meeting this goal. However, habitats are very large structures that contain a multitude of subsystems to sustain human life over long-durations in space, and one of the key challenges has been keeping weight to a minimum in order to reduce costs. Thus, light-weight and multifunctional structural materials are of great interest for habitation. NASA has started studying polymeric composite materials as potential lightweight and multifunctional structural materials for use in long-duration spaceflight. However, little is known about the survivability of these materials when exposed to the space environment outside of LEO for long durations. Thus, a study has been undertaken to investigate the durability of composite materials when exposed to long-duration radiation. Furthermore, as an addition to the primary study, a secondary preliminary investigation has been started on the micrometeoroid and orbital debris (MMOD) susceptibility of these materials after radiation exposure. The combined effects of radiation and MMOD impacts are the focus of this paper.
NASA Astrophysics Data System (ADS)
Dementyev, A. G.; Dementyev, M. A.; Zinger, P. A.; Metlyakova, I. R.
1999-03-01
The thermal conductivity of rigid closed-cell polyurethane foams during long-term aging has been studied. The similarity between the kinetics of changes in the physical and mechanical characteristics of PU foams on progressive aging is established, which is attributed to the effect of matrix destruction. It is found that rigid foams have cell walls of various strength, whose impact on the kinetics of changes in the physical characteristics of the foams during long-term aging is ascertained. The results of predicting the thermal conductivity of PU foams by the method of temperature-time analogy and establishing the limits of its application are discussed. The research presented is of interest both in determining the foam durability and in replacing freons by alternative, ecologically less harmful blowing agents.
Steam Cured Self-Consolidating Concrete and the Effects of Limestone Filler
NASA Astrophysics Data System (ADS)
Aqel, Mohammad A.
The purpose of this thesis is to determine the effect and the mechanisms associated with replacing 15% of the cement by limestone filler on the mechanical properties and durability performance of self-consolidating concrete designed and cured for precast/prestressed applications. This study investigates the role of limestone filler on the hydration kinetics, mechanical properties (12 hours to 300 days), microstructural and durability performance (rapid chloride permeability, linear shrinkage, sulfate resistance, freeze-thaw resistance and salt scaling resistance) of various self-consolidating concrete mix designs containing 5% silica fume and steam cured at a maximum holding temperature of 55°C. This research also examines the resistance to delayed ettringite formation when the concrete is steam cured at 70°C and 82°C and its secondary consequences on the freeze-thaw resistance. The effect of several experimental variables related to the concrete mix design and also the curing conditions are examined, namely: limestone filler fineness, limestone filler content, cement type, steam curing duration and steam curing temperature. In general, the results reveal that self-consolidating concrete containing 15% limestone filler, steam cured at 55°C, 70°C and 82°C, exhibited similar or superior mechanical and transport properties as well as long term durability performance compared to similar concrete without limestone filler. When the concrete is steam cured at 55°C, the chemical reactivity of limestone filler has an important role in enhancing the mechanical properties at 16 hours (compared to the concrete without limestone filler) and compensating for the dilution effect at 28 days. Although, at 300 days, the expansion of all concrete mixes are below 0.05%, the corresponding freeze-thaw durability factors vary widely and are controlled by the steam curing temperature and the chemical composition of the cement. Overall, the material properties indicate that the use of 15% limestone filler as cement replacement is a viable option for the precast/prestressed concrete applications, and in addition, would also have economic and environmental benefits.
Platinum Nickel Nanowires as Methanol Oxidation Electrocatalysts
Alia, Shaun M.; Pylypenko, Svitlana; Neyerlin, Kenneth C.; ...
2015-08-27
We investigated platinum(Pt) nickel (Ni) nanowires (PtNiNWs) as methanol oxidation reaction (MOR) catalysts in rotating disk electrode (RDE) half-cells under acidic conditions. Pt-ruthenium (Ru) nanoparticles have long been the state of the art MOR catalyst for direct methanol fuel cells (DMFCs) where Ru provides oxophilic sites, lowering the potential for carbon monoxide oxidation and the MOR onset. Ru, however, is a precious metal that has long term durability concerns. Ni/Ni oxide species offer a potential to replace Ru in MOR electrocatalysis. PtNiNWs were investigated for MOR and oxygen annealing was investigated as a route to improve catalyst performance (mass activitymore » 65% greater) and stability to potential cycling. Our results presented show that PtNiNWs offer significant promise in the area, but also result in Ni ion leaching that is a concern requiring further evaluation in fuel cells.« less
Kaygin, Bulent; Akgun, Emre
2008-01-01
The long-term durability of varnished wooden surfaces used in either indoors or outdoors environments depends on the resistance of varnish layers on these surfaces against potential physical, mechanical and chemical effects to which they may be exposed. In this study, “Nanolacke ultraviolet varnish”, developed by a Turkish dying and varnish industry company and widely accepted as a 21st century technology has been compared to other conventional varnish systems widely used in the industry in terms of dry film resistance properties. In this study, cellulosic, polyurethane, polyester, synthetic and Nanolacke ultraviolet varnish have been applied on beech (Fagus orientalis L.) and oak (Quercus robur L.) wood samples which had been prepared according to the industry standards. Then, the hardness and adhesion resistance of these layers have been determined according to ASTM D 4366 and ASTM D 3359-2 standards, respectively. PMID:19325763
Messenger, Robert W
2012-01-01
Exacerbation and frequent rehospitalization in chronic obstructive pulmonary disease exacts a heavy toll on the US health care system. To address these issues, new initiatives have been proposed that are largely based on financial penalties to promote patient education and postdischarge care. However, as laudable as these goals are, improving outcomes in the chronic obstructive pulmonary disease population is more confounding than it may first appear. Chronic hypoxia, cognitive dysfunction, poor nutrition, and economic disadvantage are just a few of the challenges that require creative solutions and ongoing support. Case managers need to utilize all the potential products and services that can assist in improving outcomes for these patients. Durable medical equipment providers are often viewed as purveyors of medical equipment that offer little in the form of clinical support. However, in many cases these providers represent an overlooked resource that provides individualized, highly structured patient education and ongoing support programs. The challenge is in identifying those durable medical equipment providers that offer patients contemporary technology, and have both the resources and the commitment to provide patient support that is amenable to the goals of the hospital. This article reviews many of the confounding issues that contribute to the frequent rehospitalization of chronic obstructive pulmonary disease patients. Recommendations to improve patient education and oxygen therapy outcomes are provided along with suggestions to aid in the vetting of durable medical equipment providers. Acute care hospitals, long-term acute care hospitals, extended care facilities, integrated delivery systems. 1. An understanding of the complex variables that play in the management of chronic obstructive pulmonary disease will help the case manager to plan an effective course of care. 2. Case managers need to ensure that patients receive long-term oxygen technology that supports their lifestyle, promotes compliance, and ultimately achieves the desired outcomes. 3. Case managers must advocate for coordinated, ongoing patient education and stress the need for continuing reinforcement. 4. Case managers must ensure that patients under their care be matched with durable medical equipment providers that provide the technology and support that favors positive clinical outcomes.
A stretchable strain sensor based on a metal nanoparticle thin film for human motion detection
NASA Astrophysics Data System (ADS)
Lee, Jaehwan; Kim, Sanghyeok; Lee, Jinjae; Yang, Daejong; Park, Byong Chon; Ryu, Seunghwa; Park, Inkyu
2014-09-01
Wearable strain sensors for human motion detection are being highlighted in various fields such as medical, entertainment and sports industry. In this paper, we propose a new type of stretchable strain sensor that can detect both tensile and compressive strains and can be fabricated by a very simple process. A silver nanoparticle (Ag NP) thin film patterned on the polydimethylsiloxane (PDMS) stamp by a single-step direct transfer process is used as the strain sensing material. The working principle is the change in the electrical resistance caused by the opening/closure of micro-cracks under mechanical deformation. The fabricated stretchable strain sensor shows highly sensitive and durable sensing performances in various tensile/compressive strains, long-term cyclic loading and relaxation tests. We demonstrate the applications of our stretchable strain sensors such as flexible pressure sensors and wearable human motion detection devices with high sensitivity, response speed and mechanical robustness.Wearable strain sensors for human motion detection are being highlighted in various fields such as medical, entertainment and sports industry. In this paper, we propose a new type of stretchable strain sensor that can detect both tensile and compressive strains and can be fabricated by a very simple process. A silver nanoparticle (Ag NP) thin film patterned on the polydimethylsiloxane (PDMS) stamp by a single-step direct transfer process is used as the strain sensing material. The working principle is the change in the electrical resistance caused by the opening/closure of micro-cracks under mechanical deformation. The fabricated stretchable strain sensor shows highly sensitive and durable sensing performances in various tensile/compressive strains, long-term cyclic loading and relaxation tests. We demonstrate the applications of our stretchable strain sensors such as flexible pressure sensors and wearable human motion detection devices with high sensitivity, response speed and mechanical robustness. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr03295k
Stone, David H; Scali, Salvatore T; Bjerk, Aja A; Rzucidlo, Eva; Chang, Catherine K; Goodney, Philip P; Nolan, Brian W; Walsh, Daniel B
2010-07-01
While much attention has been devoted toward treatment paradigms for idiopathic axillo-subclavian vein thrombosis (ASVT), little has focused on long-term durability of aggressive treatment and its associated functional outcomes. The purpose of this study was to review our own surgical therapeutic algorithm and its associated durability and functional outcomes. All patients treated with combined endovascular and open surgery at Dartmouth-Hitchcock Medical Center for ASVT from 1988 to 2008 were identified. Patient demographics, comorbidities, and operative techniques were recorded. Patency, freedom from reintervention, and functional outcomes were documented. Follow-up via telephone and clinic visit allowed quantitative comparison of functional status, pre- and postoperatively. Thirty-six patients were treated for ASVT throughout the study interval. Seven patients (19.4%) were lost to follow-up. Most patients were male (66%; N = 24); mean age was 32 years. Catheter-directed thrombolysis was utilized in the majority of patients (83.3%; N = 30) with an average time from symptom onset to lysis of 12 days. Surgical decompression was undertaken in all patients via transaxillary (52%; N = 19), supraclavicular (31%; N = 11), or infraclavicular approaches (17%; N = 6). Eleven stents were placed in 11 patients (30.5%) for residual stenotic disease. Mean follow-up was 65 months, with 1- and 5-year overall patency at 100% and 94%, respectively. Freedom from reintervention was 100% and 74.4% at 1 and 5 years, respectively. Seven patients (19.4%) required postoperative reintervention with four receiving additional lytic therapy, two requiring a stent, and one venoplasty. At presentation, 65.5% (N = 19) of patients were unable to work or perform routine activities. After treatment, 86% (N = 25) returned to their employment and have experienced sustained symptomatic and functional improvement. Patients with symptomatic idiopathic axillo-subclavian vein thrombosis can expect durable patency with sustained freedom from reintervention following aggressive combined endovascular and surgical treatment. Good functional outcomes can be expected in patients with relief of symptoms and return to work. Copyright (c) 2010 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
1975-01-01
The retention of granular catalyst in a metal foam matrix was demonstrated to greatly increase the life capability of hydrazine monopropellant reactors. Since nickel foam used in previous tests was found to become degraded after long-term exposure the cause of degradation was examined and metal foams of improved durability were developed. The most durable foam developed was a rhodium-coated nickel foam. An all-platinum foam was found to be incompatible in a hot ammonia (hydrazine) environment. It is recommended to scale up the manufacturing process for the improved foam to produce samples sufficiently large for space shuttle APU gas generator testing.
Abdollahi Nejand, B; Nazari, P; Gharibzadeh, S; Ahmadi, V; Moshaii, A
2017-01-05
Here, a low-cost perovskite solar cell using CuI and ZnO as the respective inorganic hole and electron transport layers is introduced. Copper foil is chosen as a cheap and low-weight conductive substrate which has a similar work function to ITO. Besides, copper foil is an interesting copper atom source for the growth of the upper cuprous iodide layer on copper foil. A spray coating of a transparent silver nanowire electrode is used as a top contact. The prepared device shows a maximum power conversion efficiency of 12.80% and long-term durability providing an environmentally and market friendly perovskite solar cell.
Space life support engineering program
NASA Technical Reports Server (NTRS)
Seagrave, Richard C.
1992-01-01
A comprehensive study to develop software to simulate the dynamic operation of water reclamation systems in long-term closed-loop life support systems is being carried out as part of an overall program for the design of systems for a moon station or a Mars voyage. This project is being done in parallel with a similar effort in the Department of Chemistry to develop durable accurate low-cost sensors for monitoring of trace chemical and biological species in recycled water supplies. Aspen-Plus software is being used on a group of high-performance work stations to develop the steady state descriptions for a number of existing technologies. Following completion, a dynamic simulation package will be developed for determining the response of such systems to changes in the metabolic needs of the crew and to upsets in system hardware performance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnett, Scott; Poeppelmeier, Ken; Mason, Tom
This project addresses fundamental materials challenges in solid oxide electrochemical cells, devices that have a broad range of important energy applications. Although nano-scale mixed ionically and electronically conducting (MIEC) materials provide an important opportunity to improve performance and reduce device operating temperature, durability issues threaten to limit their utility and have remained largely unexplored. Our work has focused on both (1) understanding the fundamental processes related to oxygen transport and surface-vapor reactions in nano-scale MIEC materials, and (2) determining and understanding the key factors that control their long-term stability. Furthermore, materials stability has been explored under the “extreme” conditions encounteredmore » in many solid oxide cell applications, i.e, very high or very low effective oxygen pressures, and high current density.« less
Long-Term Durability of Bioprosthetic Aortic Valves: Implications From 12,569 Implants
Johnston, Douglas R.; Soltesz, Edward G.; Vakil, Nakul; Rajeswaran, Jeevanantham; Roselli, Eric E.; Sabik, Joseph F.; Smedira, Nicholas G.; Svensson, Lars G.; Lytle, Bruce W.; Blackstone, Eugene H.
2016-01-01
Background Increased life expectancy and younger patients’ desire to avoid lifelong anticoagulation requires a better understanding of bioprosthetic valve failure. This study evaluates risk factors associated with explantation for structural valve deterioration (SVD) in a long-term series of Carpentier-Edwards PERIMOUNT aortic valves (AV). Methods From June 1982 to January 2011, 12,569 patients underwent AV replacement with Edwards Lifesciences Carpentier-Edwards PERIMOUNT stented bovine pericardial prostheses, models 2700PM (n = 310) or 2700 (n = 12,259). Mean age was 71 ± 11 years (range, 18 to 98 years). 93% had native AV disease, 48% underwent concomitant coronary artery bypass grafting, and 26% had additional valve surgery. There were 81,706 patient-years of systematic follow-up data available for analysis. Demographics, intraoperative variables, and 27,386 echocardiographic records were used to identify risks for explant for SVD and assess longitudinal changes in transprosthesis gradients using time-varying covariable analyses. Results Three hundred fifty-four explants were performed, with 41% related to endocarditis and 44% to SVD. Actuarial estimates of explant for SVD at 10 and 20 years were 1.9% and 15% overall, respectively, and in patients younger than 60 years, 5.6% and 46%, respectively. Younger age (p < 0.0001), lipid-lowering drugs (p = 0.002), prosthesis–patient mismatch (p = 0.001), and higher postoperative peak and mean AV gradients were associated with explant for SVD (p < 0.0001). The effect of gradient on SVD was greatest in patients younger than 60 years. Conclusions Durability of the Carpentier-Edwards PERIMOUNT aortic valve is excellent even in younger patients. Explant for SVD is related to gradient at implantation, especially in younger patients. Strategies to reduce early postoperative AV gradients, such as root enlargement or more efficient prostheses, should be considered. PMID:25662439
Mesquita, A M M; Ozcan, M; Souza, R O A; Kojima, A N; Nishioka, R S; Kimpara, E T; Bottino, M A
2010-01-01
This study compared the bond strength durability of a feldspathic veneering ceramic to glass-infiltrated reinforced ceramics in dry and aged conditions. Disc shaped (thickness: 4 mm, diameter: 4 mm) of glass-infiltrated alumina (In-Ceram Alumina) and glass-infiltrated alumina reinforced by zirconia (In-Ceram Zirconia) core ceramic specimens (N=48, N=12 per groups) were constructed according to the manufacturers' recommendations. Veneering ceramic (VITA VM7) was fired onto the core ceramics using a mold. The core-veneering ceramic assemblies were randomly divided into two conditions and tested either immediately after specimen preparation (Dry) or following 30000 thermocycling (5-55 ºC±1; dwell time: 30 seconds). Shear bond strength test was performed in a universal testing machine (cross-head speed: 1 mm/min). Failure modes were analyzed using optical microscope (x20). The bond strength data (MPa) were analyzed using ANOVA (α=0.05). Thermocycling did not decrease the bond strength results for both In-Ceram Alumina (30.6±8.2 MPa; P=0.2053) and In-Ceram zirconia (32.6±9 MPa; P=0.3987) core ceramic-feldspathic veneering ceramic combinations when compared to non-aged conditions (28.1±6.4 MPa, 29.7±7.3 MPa, respectively). There were also no significant differences between adhesion of the veneering ceramic to either In-Ceram Alumina or In-Ceram Zirconia ceramics (P=0.3289). Failure types were predominantly a mixture of adhesive failure between the veneering and the core ceramic together with cohesive fracture of the veneering ceramic. Long-term thermocycling aging conditions did not impair the adhesion of the veneering ceramic to the glass-infiltrated alumina core ceramics tested.
Hungness, Eric S; Sternbach, Joel M; Teitelbaum, Ezra N; Kahrilas, Peter J; Pandolfino, John E; Soper, Nathaniel J
2016-09-01
We aimed to report long-term outcomes for patients undergoing per-oral endoscopic myotomy (POEM) after our initial 15-case learning curve. POEM has become an established, natural-orifice surgical approach for treating esophageal motility disorders. To date, published outcomes and comparative-effectiveness studies have included patients from the early POEM experience. Consecutive patients undergoing POEM after our initial 15 cases, with a minimum of 1-year postoperative follow-up, were included. Treatment success was defined as an Eckardt score ≤3 without reintervention. Gastroesophageal reflux was defined by abnormal pH-testing or reflux esophagitis >Los Angeles grade A. Between January 2012 and March 2015, 115 patients underwent POEM at a single, high-volume center. Operative time was 101 ± 29 minutes, with 95% (109/115) of patients discharged on postoperative day 1. Clavien-Dindo grade III complications occurred in 2.7%, one of which required diagnostic laparoscopy to rule out Veress needle injury to the gall bladder. The rate of grade I complications was 15.2%. At an average of 2.4 years post-POEM (range 12-52 months), the overall success rate was 92%. Objective evidence of reflux was present in 40% for all patients and 33% for patients with a body mass index <35 kg/m and no hiatal hernia. POEM performed by experienced surgeons provided durable symptomatic relief in 94% of patients with nonspastic achalasia and 90% of patients with type 3 achalasia/spastic esophageal motility disorders, with a low rate of complications. The rate of gastroesophageal reflux was comparable with prior studies of both POEM and laparoscopic Heller myotomy.
Durkan, Rukiye Kaplan; Ozel, M Birol; Celik, Davut; Bağiş, Bora
2008-12-01
This report describes an esthetic, conservative, and economical alternative restoration technique for a fractured central incisor using the patient's own tooth crown piece and a bondable reinforcement glass fiber. Although the long-term durability of this adhesive post core restoration remains unknown, it remains successful after 1 year.
Identifying Stem-like Cells Using Mitochondrial Membrane Potential | Center for Cancer Research
Therapies that are based on living cells promise to improve treatments for metastatic cancer and for many degenerative diseases. Lasting treatment of these maladies may require the durable persistence of cells. Long-term engraftment of cells – for months or years – and the generation of large numbers of progeny are characteristics of stem cells. Most approaches to isolate
Effect of Ni content on the morphological evolution of Ni-YSZ solid oxide fuel cell electrodes
Chen-Wiegart, Yu-chen Karen; Kennouche, David; Scott Cronin, J.; ...
2016-02-25
The coarsening of Ni in Ni–yttria-stabilized zirconia (YSZ) anodes is a potential cause of long term solid oxide fuel cells (SOFC) performance degradation. The specifics of the Ni-YSZ structure—including Ni/YSZ ratio, porosity, and particle size distributions—are normally selected to minimize anode polarization resistance, but they also impact long-term stability. A better understanding of how these factors influence long-term stability is important for designing more durable anodes. The effect of structural details, e.g., Ni-YSZ ratio, on Ni coarsening has not been quantified. Furthermore, prior measurements have been done by comparing evolved structures with control samples, such that sample-to-sample variations introduce errors.more » Here in this paper, we report a four dimensional (three spatial dimensions and time) study of Ni coarsening in Ni-YSZ anode functional layers with different Ni/YSZ ratios, using synchrotron x-ray nano-tomography. The continuous structural evolution was observed and analyzed at sub-100 nm resolution. It is shown quantitatively that increasing the Ni/YSZ ratio increases the Ni coarsening rate. This is due to both increased pore volume and a decrease in the YSZ volume fraction, such that there is more free volume and a less obtrusive YSZ network, both of which allow greater Ni coarsening. The results are shown to be in good agreement with a power-law coarsening model. In conclusion, the finding is critical for informing the design of SOFC electrode microstructures that limit coarsening and performance degradation.« less
Effect of Ni content on the morphological evolution of Ni-YSZ solid oxide fuel cell electrodes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen-Wiegart, Yu-chen Karen; Kennouche, David; Scott Cronin, J.
The coarsening of Ni in Ni–yttria-stabilized zirconia (YSZ) anodes is a potential cause of long term solid oxide fuel cells (SOFC) performance degradation. The specifics of the Ni-YSZ structure—including Ni/YSZ ratio, porosity, and particle size distributions—are normally selected to minimize anode polarization resistance, but they also impact long-term stability. A better understanding of how these factors influence long-term stability is important for designing more durable anodes. The effect of structural details, e.g., Ni-YSZ ratio, on Ni coarsening has not been quantified. Furthermore, prior measurements have been done by comparing evolved structures with control samples, such that sample-to-sample variations introduce errors.more » Here in this paper, we report a four dimensional (three spatial dimensions and time) study of Ni coarsening in Ni-YSZ anode functional layers with different Ni/YSZ ratios, using synchrotron x-ray nano-tomography. The continuous structural evolution was observed and analyzed at sub-100 nm resolution. It is shown quantitatively that increasing the Ni/YSZ ratio increases the Ni coarsening rate. This is due to both increased pore volume and a decrease in the YSZ volume fraction, such that there is more free volume and a less obtrusive YSZ network, both of which allow greater Ni coarsening. The results are shown to be in good agreement with a power-law coarsening model. In conclusion, the finding is critical for informing the design of SOFC electrode microstructures that limit coarsening and performance degradation.« less
Gurel, Galip; Morimoto, Susana; Calamita, Marcelo A; Coachman, Christian; Sesma, Newton
2012-12-01
This article evaluates the long-term clinical performance of porcelain laminate veneers bonded to teeth prepared with the use of an additive mock-up and aesthetic pre-evaluative temporary (APT) technique over a 12-year period. Sixty-six patients were restored with 580 porcelain laminate veneers. The technique, used for diagnosis, esthetic design, tooth preparation, and provisional restoration fabrication, was based on the APT protocol. The influence of several factors on the durability of veneers was analyzed according to pre- and postoperative parameters. With utilization of the APT restoration, over 80% of tooth preparations were confined to the dental enamel. Over 12 years, 42 laminate veneers failed, but when the preparations were limited to the enamel, the failure rate resulting from debonding and microleakage decreased to 0%. Porcelain laminate veneers presented a successful clinical performance in terms of marginal adaptation, discoloration, gingival recession, secondary caries, postoperative sensitivity, and satisfaction with restoration shade at the end of 12 years. The APT technique facilitated diagnosis, communication, and preparation, providing predictability for the restorative treatment. Limiting the preparation depth to the enamel surface significantly increases the performance of porcelain laminate veneers.
Li, Tianyu; Chen, Yongmei; Wan, Pingyu; Fan, Maohong; Yang, X Jin
2010-03-03
The candidature of Fe-Si and Mg-Al alloys at millimeter-scale particle sizes for chemical degradation of disinfection byproducts (DBPs) in drinking water systems was substantiated by their enhanced corrosion resistance and catalytic effect on the degradation. The Mg-Al particles supplied electrons for reductive degradation, and the Fe-Si particles acted as a catalyst and provided the sites for the reaction. The alloy particles are obtained by mechanical milling and stable under ambient conditions. The proposed method for chemical degradation of DBPs possesses the advantages of relatively constant degradation performance, long-term durability, no secondary contamination, and ease of handling, storage and maintenance in comparison with nanoparticle systems.
Gurvitch, R; Wood, D A; Tay, E L; Leipsic, J; Ye, J; Lichtenstein, S V; Thompson, C R; Carere, R G; Wijesinghe, N; Nietlispach, F; Boone, R H; Lauck, S; Cheung, A; Webb, J G
2010-09-28
Although short- and medium-term outcomes after transcatheter aortic valve implantation are encouraging, long-term data on valve function and clinical outcomes are limited. Consecutive high-risk patients who had been declined as surgical candidates because of comorbidities but who underwent successful transcatheter aortic valve implantation with a balloon-expandable valve between January 2005 and December 2006 and survived past 30 days were assessed. Clinical, echocardiographic, and computed tomographic follow-up examinations were performed. Seventy patients who underwent successful procedures and survived longer than 30 days were evaluated at a minimum follow-up of 3 years. At a median follow-up of 3.7 years (interquartile range 3.4 to 4.3 years), survival was 57%. Survival at 1, 2, and 3 years was 81%, 74%, and 61%, respectively. Freedom from reoperation was 98.5% (1 patient with endocarditis). During this early procedural experience, 11 patients died within 30 days, and 8 procedures were unsuccessful. When these patients were included, overall survival was 51%. Transaortic pressure gradients increased from 10.0 mm Hg (interquartile range 8.0 to 12.0 mm Hg) immediately after the procedure to 12.1 mm Hg (interquartile range 8.6 to 16.0 mm Hg) after 3 years (P=0.03). Bioprosthetic valve area decreased from a mean of 1.7±0.4 cm(2) after the procedure to 1.4±0.3 cm(2) after 3 years (P<0.01). Aortic incompetence after implantation was trivial or mild in 84% of cases and remained unchanged or improved over time. There were no cases of structural valvular deterioration, stent fracture, deformation, or valve migration. Transcatheter aortic valve implantation demonstrates good medium- to long-term durability and preserved hemodynamic function, with no evidence of structural failure. The procedure appears to offer an adequate and lasting resolution of aortic stenosis in selected patients.
Liao, Hang; Miao, Xinxin; Ye, Jing; Wu, Tianlong; Deng, Zhongbo; Li, Chen; Jia, Jingyu; Cheng, Xigao; Wang, Xiaolei
2017-04-19
Inspired from falling leaves, ZnO nanorods-nanoslices hierarchical structure (NHS) was constructed to modify the surfaces of two widely used implant materials: titanium (Ti) and tantalum (Ta), respectively. By which means, two-stage release of antibacterial active substances were realized to address the clinical importance of long-term broad-spectrum antibacterial activity. At early stages (within 48 h), the NHS exhibited a rapid releasing to kill the bacteria around the implant immediately. At a second stage (over 2 weeks), the NHS exhibited a slow releasing to realize long-term inhibition. The excellent antibacterial activity of ZnO NHS was confirmed once again by animal test in vivo. According to the subsequent experiments, the ZnO NHS coating exhibited the great advantage of high efficiency, low toxicity, and long-term durability, which could be a feasible manner to prevent the abuse of antibiotics on implant-related surgery.
Hoya, Yoshiyuki; Taki, Tetsuya; Watanabe, Atsushi; Nakayoshi, Tomoko; Okamoto, Tomoyoshi; Mitsumori, Norio; Yanaga, Katsuhiko
2016-04-01
We have reported the short-term results of pylorus reconstruction gastrectomy (PRG) that prevents duodenogastric reflux (DGR) and remnant gastritis after distal gastrectomy. We herein report the long-term results of the PRG. PRG was performed in 37 patients (age 31 to 86 [mean 67.8 ± 12.3] years, male:female = 22:15) with gastric cancer from June 2006 through December 2013. We examined the long-term outcome in 28 patients (age 41 to 86 [mean 67.0 ± 10.7] years, male:female = 18:10) that passed over 3 years after surgery (LTR 44.1 ± 11.7 months), and compared with their short-term result after the operation (STR 13.1 ± 6.9 months). The adverse events of gastric surgery evaluated in this study consisted of the degree of remnant gastritis, the presence of dumping syndrome, and degree of weight loss (%). There was no difference in the degree of DGR and remnant gastritis by gastroscopic finding between LTR and STR after PRG (P = 0.21). Statistically, there was no difference in the bile acid concentration of remnant gastric juice between LTR and STR (108.4 ± 254.1 vs. 94.0 ± 208.6 μmol/L, P = 0.33), and weight loss of LTR was the same as that of STR (5.67 ± 7.08 vs. 4.59 ± 5.63%, P = 0.34). There were few morphological changes in the reconstructed pylorus by the long-term course, but 2 patients showed mild atrophy. The form of reconstructed pylorus and the effect that reduces side effects of Billroth I seem to last for a long time.
Freeze-Thaw Durability of Air-Entrained Concrete
Shang, Huai-Shuai; Yi, Ting-Hua
2013-01-01
One of the most damaging actions affecting concrete is the abrupt temperature change (freeze-thaw cycles). The types of deterioration of concrete structures by cyclic freeze-thaw can be largely classified into surface scaling (characterized by the weight loss) and internal crack growth (characterized by the loss of dynamic modulus of elasticity). The present study explored the durability of concrete made with air-entraining agent subjected to 0, 100, 200, 300, and 400 cycles of freeze-thaw. The experimental study of C20, C25, C30, C40, and C50 air-entrained concrete specimens was completed according to “the test method of long-term and durability on ordinary concrete” GB/T 50082-2009. The dynamic modulus of elasticity and weight loss of specimens were measured after different cycles of freeze-thaw. The influence of freeze-thaw cycles on the relative dynamic modulus of elasticity and weight loss was analyzed. The findings showed that the dynamic modulus of elasticity and weight decreased as the freeze-thaw cycles were repeated. They revealed that the C30, C40, and C50 air-entrained concrete was still durable after 300 cycles of freeze-thaw according to the experimental results. PMID:23576906
Freeze-thaw durability of air-entrained concrete.
Shang, Huai-Shuai; Yi, Ting-Hua
2013-01-01
One of the most damaging actions affecting concrete is the abrupt temperature change (freeze-thaw cycles). The types of deterioration of concrete structures by cyclic freeze-thaw can be largely classified into surface scaling (characterized by the weight loss) and internal crack growth (characterized by the loss of dynamic modulus of elasticity). The present study explored the durability of concrete made with air-entraining agent subjected to 0, 100, 200, 300, and 400 cycles of freeze-thaw. The experimental study of C20, C25, C30, C40, and C50 air-entrained concrete specimens was completed according to "the test method of long-term and durability on ordinary concrete" GB/T 50082-2009. The dynamic modulus of elasticity and weight loss of specimens were measured after different cycles of freeze-thaw. The influence of freeze-thaw cycles on the relative dynamic modulus of elasticity and weight loss was analyzed. The findings showed that the dynamic modulus of elasticity and weight decreased as the freeze-thaw cycles were repeated. They revealed that the C30, C40, and C50 air-entrained concrete was still durable after 300 cycles of freeze-thaw according to the experimental results.
Kim, Jaehwan; Jeon, Jin-Han; Kim, Hyun-Jun; Lim, Hyuneui; Oh, Il-Kwon
2014-03-25
Ionic polymer actuators driven by electrical stimuli have been widely investigated for use in practical applications such as bioinspired robots, sensors, and biomedical devices. However, conventional ionic polymer-metal composite actuators have a serious drawback of poor durability under long-term actuation in open air, mainly because of the leakage of the inner electrolyte and hydrated cations through cracks in the metallic electrodes. Here, we developed a highly durable and water-floatable ionic polymer artificial muscle by employing hydrophobic and asymmetrically laser-scribed reduced graphene oxide paper electrodes (HLrGOP). The highly conductive, flexible, and cost-effective HLrGOP electrodes have asymmetrically smooth hydrophobic outer and rough inner surfaces, resulting in liquid-impermeable and water-floatable functionalities and strong bonding between an ionic polymer and the electrodes. More interestingly, the HLrGOP electrode, which has a unique functionality to prevent the leakage of the vaporized or liquid electrolyte and mobile ions during electrical stimuli, greatly contributes to an exceptionally durable ionic polymer-graphene composite actuator that is a prerequisite for practical applications in active biomedical devices, biomimetic robots, touch-feedback haptic systems, and flexible soft electronics.
Sun, Yuxia; Ma, Hong; Luo, Yang; Zhang, Shujing; Gao, Jin; Xu, Jie
2018-03-26
It has long been a challenge for activating O 2 by transition-metal nanocatalysts, which might lose activity due to strong tendency for oxidation. Herein, O 2 could be activated by durable encapsulated cobalt nanoparticles (NPs) with N-doped graphitic carbon shells (Co@N-C), but not by encapsulated cobalt NPs with graphitic carbon, exposed cobalt NPs supported on activated carbon, or N-doped carbon. Electron paramagnetic resonance, real-time in situ FTIR spectroscopy, and mass spectrometry measurements demonstrated the generation of the highly active superoxide radical, O 2 .- . This unique ability enables Co@N-C to afford an excellent catalytic performance in model aerobic oxidation of monomeric lignin-derived alcohols. Further analysis elucidated that encapsulated cobalt and nitrogen-doped graphitic carbon might contribute to the capacity through influencing the electronic properties of outer layers. Moreover, through isolation by N-doped graphitic carbon shells, the inner metallic cobalt NPs are inaccessible in term of either alcohols or oxygenated products, and a distinctive resistance to leaching and agglomeration has been achieved. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Nanomechanical Behavior of High Gas Barrier Multilayer Thin Films.
Humood, Mohammad; Chowdhury, Shahla; Song, Yixuan; Tzeng, Ping; Grunlan, Jaime C; Polycarpou, Andreas A
2016-05-04
Nanoindentation and nanoscratch experiments were performed on thin multilayer films manufactured using the layer-by-layer (LbL) assembly technique. These films are known to exhibit high gas barrier, but little is known about their durability, which is an important feature for various packaging applications (e.g., food and electronics). Films were prepared from bilayer and quadlayer sequences, with varying thickness and composition. In an effort to evaluate multilayer thin film surface and mechanical properties, and their resistance to failure and wear, a comprehensive range of experiments were conducted: low and high load indentation, low and high load scratch. Some of the thin films were found to have exceptional mechanical behavior and exhibit excellent scratch resistance. Specifically, nanobrick wall structures, comprising montmorillonite (MMT) clay and polyethylenimine (PEI) bilayers, are the most durable coatings. PEI/MMT films exhibit high hardness, large elastic modulus, high elastic recovery, low friction, low scratch depth, and a smooth surface. When combined with the low oxygen permeability and high optical transmission of these thin films, these excellent mechanical properties make them good candidates for hard coating surface-sensitive substrates, where polymers are required to sustain long-term surface aesthetics and quality.
NASA Astrophysics Data System (ADS)
Kim, Sung-Kon; Kim, Ki-Hyun; Park, Jung Ock; Kim, Kihyun; Ko, Taeyun; Choi, Seong-Woo; Pak, Chanho; Chang, Hyuk; Lee, Jong-Chan
2013-03-01
For polymer electrolyte membrane fuel cell (PEMFC) applications at elevated temperature (>100 °C), a series of cross-linked benzoxazine-benzimidazole copolymer, P(HFa-co-BI), membranes are prepared by casting a solution of poly[2,2‧-(m-phenylene)-5,5‧-bibenzimidazole] (PBI) and di-functional benzoxazine monomer, 6,6‧-(hexafluoroisopropylidene)bis(3-phenyl-3,4-dihydro-2H-benzoxazine) (HFa), in N,N-dimethylacetamide prior to stepwise heating to 250 °C. The films are also viable to manufacture to large quantities and area by roll-to-roll coating. The resulting cross-linked copolymer, P(HFa-co-BI), membranes are found to be thermally and mechanically stable. Although the proton conductivity values of P(HFa-co-BI) membranes are smaller than that of the PBI membrane, their cell performance (0.68 V at 0.2 A cm-2 at 150 °C) is close to that of PBI membrane and their long-term durability (ca. 3116 cycles on in situ accelerated lifetime mode of load cycling testing) is found to be far superior to the PBI membrane.
Technology Solutions Case Study: Guidance on Taped Insulating Sheathing Drainage Planes
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
The energy efficiency-based financial benefits of adding exterior insulation are well accepted by the building industry, and using exterior insulation as the drainage plane is the next logical step. This case study focuses on the field implementation of taped board insulation as the drainage plane in both new and retrofit residential applications, and provides information and recommendations for insulation contractors, general contractors, builders, remodelers, mechanical contractors, and homeowners. The order of work completed during home construction and retrofit improvements is important. Health and safety issues must be addressed first and are more important than durability issues, and durability issues aremore » more important than saving energy. Three significant items are required to make taped insulating sheathing a simple, long term, and durable drainage plane: first, horizontal joints should be limited or eliminated wherever possible; where a horizontal joint exists, use superior materials; and, frequent installation inspection and regular trade training are required to maintain proper installation.« less
NASA Astrophysics Data System (ADS)
Saçkes, Mesut; Trundle, Kathy Cabe
2017-06-01
This longitudinal study examined the role of metaconceptual awareness in the change and the durability of preservice teachers' conceptual understandings over the course of several months. Sixteen preservice early childhood teachers participated in the study. Semi-structured interviews were conducted to reveal the participants' conceptual understandings of lunar phases (pre, post, and delayed-post) and level of metaconceptual awareness (delayed-post only). Based on the change and stability in participants' conceptual understandings from pre to post and from post to delayed-post interviews, participants' conceptual understandings were assigned into three groups that described the profile of their long-term conceptual understandings: " decay or stability", " continuous growth", and " growth and stability". The results indicated that participants in the " continuous growth" and " growth and stability" groups had significantly higher metaconceptual awareness scores than participants in the " decay or stability" group. The results provided evidence that metaconceptual awareness plays a more decisive role in the restructuring of conceptual understandings than the durability of conceptual understandings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ruggles-Wrenn, M.B.
2003-10-06
The Durability of Lightweight Composite Structures Project was established at Oak Ridge National Laboratory (ORNL) by the U.S. Department of Energy to provide the experimentally-based, durability-driven design guidelines necessary to assure long-term structural integrity of automotive composite components. The initial focus of the ORNL Durability Project was on composite materials consisting of polyurethane reinforced with E-glass. Current focus of the project is on composite materials reinforced with carbon fibers. The primary purpose of this report is to provide the individual specimen test date. Basic mechanical property testing and results for two chopped-fiber composite materials, one reinforced with glass- and themore » other with carbon fiber are provided. Both materials use the same polyurethane matrix. Preforms for both materials were produced using the P4 process. Behavioral trends, effects of temperature and environment, and corresponding design knockdown factors are established for both materials. Effects of prior short-time loads and of prior thermal cycling are discussed.« less
NASA Technical Reports Server (NTRS)
Hinkley, Jeffrey A.; Connell, John W.
2012-01-01
In choosing a polymer-matrix composite material for a particular application, a number of factors need to be weighed. Among these are mechanical requirements, fabrication method (e.g. press-molding, resin infusion, filament winding, tape layup), and use conditions. Primary among the environmental exposures encountered in aerospace structures are moisture and elevated temperatures, but certain applications may require resistance to other fluids and solvents, alkaline agents, thermal cycling, radiation, or rapid, localized heating (for example, lightning strike). In this chapter, the main classes of polymer resin systems found in aerospace composites will be discussed. Within each class, their responses to environmental factors and the associated degradation mechanisms will be reviewed.
Advanced Environmental Barrier Coatings Developed for SiC/SiC Composite Vanes
NASA Technical Reports Server (NTRS)
Lee, Kang N.; Fox, Dennis S.; Eldridge, Jeffrey I.; Zhu, Dongming; Bansal, Narottam P.; Miller, Robert A.
2003-01-01
Ceramic components exhibit superior high-temperature strength and durability over conventional component materials in use today, signifying the potential to revolutionize gas turbine engine component technology. Silicon-carbide fiber-reinforced silicon carbide ceramic matrix composites (SiC/SiC CMCs) are prime candidates for the ceramic hotsection components of next-generation gas turbine engines. A key barrier to the realization of SiC/SiC CMC hot-section components is the environmental degradation of SiC/SiC CMCs in combustion environments. This is in the form of surface recession due to the volatilization of silica scale by water vapor. An external environmental barrier coating (EBC) is a logical approach to achieve protection and long-term durability.
Durability of bends in high-temperature steam lines under the conditions of long-term operation
NASA Astrophysics Data System (ADS)
Katanakha, N. A.; Semenov, A. S.; Getsov, L. B.
2015-04-01
The article presents the results of stress-strain state computations and durability of bent and steeply curved branches of high-temperature steam lines carried out on the basis of the finite element method using the modified Soderberg formula for describing unsteady creep processes with taking the accumulation of damage into account. The computations were carried out for bends made of steel grades that are most widely used for manufacturing steam lines (12Kh1MF, 15Kh1M1F, and 10Kh9MFB) and operating at different levels of inner pressure and temperature. The solutions obtained using the developed creep model are compared with those obtained using the models widely used in practice.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aoki, K.; Fujii, N.; Kageyama, H.
Durability of selected hard materials as information preserving media has been studied, leading to some promising results. Several engraving experiments on the selected materials confirmed that characters and patterns can be expressed along with shading and gradation. Engraving experiments on durable artificial materials were carried out by applying laser technologies. By selecting appropriate materials and engraving methods, characters and patterns can be expressed along with shading and gradation. These technologies can be applied to not only documentary records but also to markers and monuments. Among the materials, silicon carbide, which has strong resistance against heat wear and chemical impacts, corrosionmore » resistance and wear resistance, showed satisfactory results in terms of accuracy. Thus, it is expected to be a promising material for the long-term record preservation. With respect to the density of characters in written records in the case of dot printing, it was estimated that, with 2-point characters, information totaling 6 to 8 pages of A-4 size can be engraved on a 10 cm x 10 cm plate. When a document that has 500 pages of A4 size paper is engraved on sintered silicon carbide plates, the total volume of recording media is evaluated as follows: - Size of plate: 10 cm x 10 cm; - Size of character to be engraved: 2-points ({approx} 0.7 mm; of readable size by naked eye or using a magnifying glass); - Number of pages of original document to be engraved on a plate: 8; - Number of pages of original document to be engraved on both sides of a plate: 16; - Number of plates needed for a series of document package: 500 / 16 = 32; - The thickness of a plate: 1 mm; - The total thickness of recording media: 32 mm; - Bulk of recording media preserving 500 pages of document: 10 cm x 10 cm x 32 cm. The examination has shown the possibility of long-term preservation of documentation records as a permanent system. A further examination is suggested concerning the assessment of the durability of the sintered silicon carbide plate against wear and chemical impacts. Preserving color pictures and photographs for a long-term duration is also proposed. In conclusion: We have proposed that the concept of a record preservation system is the combination of several different methods in order to impart redundancy to the communication function. The system should be robust that its overall function would not be influenced by partial damage, and also be flexible enough to adapt to the changes of background conditions in the future. Records and information should be preserved by way of both Relay System and Permanent System. The former would maintain record preservation and communication functions in the framework of social systems whereas the latter would consist of durable storehouse facilities, recording media and markers/monuments and be independent of any social systems and human control. Silicon carbide is one of the most promising materials for the Permanent System of Records Preservation. It is expected to be the potential candidate for long-term recording media with its superior characteristics of resistance against heat, wear and chemical impacts, and of engraving accuracy. (authors)« less
Long-term durability of HT-PEM fuel cells based on thermally cross-linked polybenzimidazole
NASA Astrophysics Data System (ADS)
Søndergaard, Tonny; Cleemann, Lars Nilausen; Becker, Hans; Aili, David; Steenberg, Thomas; Hjuler, Hans Aage; Seerup, Larisa; Li, Qingfeng; Jensen, Jens Oluf
2017-02-01
Long-term durability of high temperature polymer electrolyte membrane fuel cells based on thermally cross-linked polybenzimidazole membranes was studied and compared with reference membranes based on linear polybenzimidazole. The test was conducted at 160 °C under constant load currents of 200 mA cm-2 for periods of 1000, 4400, and 13,000 h. Extensive beginning-of-life (BoL) and end-of-test (EoT) characterisation was carried out, and disturbance of the steady state operated cells was minimised by limiting in-line diagnostics to the low-invasive technique of electrochemical impedance spectroscopy (EIS). Up until the operating time of 9200 h, the cell equipped with the cross-linked membrane showed an average degradation rate of 0.5 μV h-1, compared to 2.6 μV h-1 for the reference membrane, though parallel tests for a shorter period of time showed deviations, likely due to malfunctioning contact between layers or cell components. For the full test period of 13,000 h, the average voltage decay rate was about 1.4 and 4.6 μV h-1 for cells equipped with cross-linked and linear polybenzimidazole membranes, respectively. EIS and post-test analysis revealed that the cross-linked membrane showed better stability in terms of area specific resistance due to improved acid retention characteristics.
NASA Astrophysics Data System (ADS)
Vettorello, Gianfranco; Marini, Leonardo
2009-06-01
Purpose: The aim is to verify short-term results in Endovenous Laser Treatment (EVLT) performed in haemodynamic way in patients belonging to C2, C3 classes and type I, II, III venous shunts, according respectively with CEAP and Teupitz classification. Methods: Minor changes of technique were applied to EVLT in order to provide haemodynamic conditions. Treatment efficacy, anatomical failure, complications, recurrence rate and clinical improvements were analyzed. 105 limbs were treated from November 2004 to November 2007. Clinical and Echo-Colour-Doppler (ECD) follow up was performed two weeks, one, two and three years after the surgery. Results: in 79 inferior limbs follow-up was concluded and this are the final data: a) no Deep Venous Thrombosis (DVT) was detected; b) a notable reduction of recurrence if compared with groin recurrence rate in traditional stripping; e) satisfactory cosmetic results and short recovery were found in all the patients. Conclusions: In selected patients haemodynamic-guided EVLT is equally safe and efficient than standard. Clinical and aesthetical outcomes are durable without statistical differences on the plan of disease progression and complications. The recurrence rate is lower in EVLT haemodynamic-guided surgery than in conventional stripping. Long-term outcomes should be investigated. We need studies camparison among the three different kind of surgery performed in haemodynamic way
NASA Astrophysics Data System (ADS)
Kim-Hak, David; Huang, Kuan; Winkler, Renato
2016-04-01
The recent advancements of the laser-based technology -in particular Cavity Ring Down Spectroscopy, CRDS- gave birth to a new generation of water stable isotope analyzers that are user-friendly, compact and field deployable providing in-situ measurements. Furthermore, with last year's launch of the Continuous Water Sampler front-end, CWS, the analyzer system added two additional dimensions to liquid water measurements: real-time and continuous. These features enable the user to construct high resolution water isotope data sets through time and space. Campaigns on the Sacramento-San Joaquin River Delta with the US Geological Survey where the CWS-CRDS system was deployed onto a boat to spatially map sections of the delta, validated the CWS performance and demonstrated its durability on brackish water. The next step for the CWS is to explore oceanic applications with seawater. Early in-house laboratory experiments showed stable performance with brine waters (3% concentration). For the field experiment, we have collaborated with the China State Oceanic Administration to deploy the CWS-CRDS in oceanic environments on cruises along the costal China and Antarctic. Here, we present the results of the analysis collected onboard and compared them with discrete sampling measurements. The long-term test has also allowed us to assess the durability and expected lifetime of the CWS membrane and to recommend the proper maintenance procedure for optimum performance under oceanic conditions.
NASA Astrophysics Data System (ADS)
Kim-Hak, D.; Huang, K.
2016-02-01
The recent advancements of the laser-based technology -in particular Cavity Ring Down Spectroscopy, CRDS- gave birth to a new generation of water stable isotope analyzers that are user-friendly, compact and field deployable providing in-situ measurements. Furthermore, with last year's launch of the Continuous Water Sampler front-end, CWS, the analyzer system added two additional dimensions to liquid water measurements: real-time and continuous. These features enable the user to construct high resolution water isotope data sets through time and space. Campaigns on the Sacramento-San Joaquin River Delta with the US Geological Survey where the CWS-CRDS system was deployed onto a boat to spatially map sections of the delta, validated the CWS performance and demonstrated its durability on brackish water. The next step for the CWS is to explore oceanic applications with seawater. Early in-house laboratory experiments showed stable performance with brine waters (3% concentration). For the field experiment, we have collaborated with the China State Oceanic Administration to deploy the CWS-CRDS in oceanic environments on cruises along the costal China and Antarctic. Here, we present the results of the analysis collected onboard and compared them with discrete sampling measurements. The long-term test has also allowed us to assess the durability and expected lifetime of the CWS membrane and to recommend the proper maintenance procedure for optimum performance under oceanic conditions.
The Short- and Long-Term Effects of a Short Study Abroad Experience: The Case of Children
ERIC Educational Resources Information Center
Llanes, Angels
2012-01-01
This study examines to what extent L2 gains obtained during a study abroad (SA) experience are durable. Participants were 16 Catalan/Spanish bilingual children, learning English as an L2, who were distributed into two groups depending on their learning context (SA vs. at home [AH]). Participants completed a pre-test before the SA participants'…
Anke Schirp; Rebecca E. Ibach; David E. Pendleton; Michael P. Wolcott
2008-01-01
Much of the research on wood-plastic composites (WPC) has focused on formulation development and processing while high biological durability of the material was assumed. The gap between assumption and knowledge in biodeterioration of WPC needs to be reduced. Although some information on the short-term resistance of WPC against biological degradation is available, long-...
Samuel L. Zelinka; Douglas R. Rammer
2005-01-01
Although preservative treatments prolong the life of wood, they can also contribute to the corrosion of fasteners. The corrosion of fasteners merits further study because it can affect the long-term durability of structures and fundamental knowledge of corrosion in wood is limited. The goal of this study is to determine the viability of electrochemical impedance...
ERIC Educational Resources Information Center
Whittal, Maureen L.; Robichaud, Melisa; Thordarson, Dana S.; McLean, Peter D.
2008-01-01
Relatively little is known about the long-term durability of group treatments for obsessive-compulsive disorder (OCD) and contemporary cognitive treatments. The current study investigated the 2-year follow-up results for participants who completed randomized trials of group or individual treatment and received either cognitive therapy (CT) or…
NASA Astrophysics Data System (ADS)
Zha, Daosong; Fu, Yongsheng; Zhang, Lili; Zhu, Junwu; Wang, Xin
2018-02-01
Nickel cobalt sulfides (NiCo-S) are promising electrode materials for high-performance supercapacitors but normally show poor rate capability and unsatisfactory long-term endurance. To overcome these disadvantages, a properly constructed electrode architecture with abundant electron transport channels, excellent electronic conductivity and robust structural stability is required. Herein, considering that in situ transformation can mostly retain the specific structural advantages of the precursors, a two-step strategy is purposefully developed to construct a binder-free electrode composed of interconnected NiCo-S nanosheets on Ni foam (NiCo-S/NF), in which NiCo-S/NF is synthesized via the in situ sulfuration of networked acetate anion-intercalated nickel cobalt layered double hydroxide nanosheets loaded on Ni foam (A-NiCo-LDH/NF). Noticeably, the optimized Ni1Co1-S/NF exhibits an ultrahigh specific capacitance of 2553.9 F g-1 at 0.5 A g-1, excellent rate capability (1898.1 F g-1 at 50 A g-1) and superior cycling stability (nearly 90% capacitance retention after 10,000 cycles). Furthermore, the assembled asymmetric supercapacitor based on Ni1Co1-S/NF demonstrates a high energy density of 58.1 Wh kg-1 at a power density of 796 W kg-1 and impressive long-term durability even after a repeated charge/discharge process as long as 70,000 cycles (∼92% capacitance retention). The attractive properties endow the Ni1Co1-S/NF electrode with significant potential for high-performance energy storage devices.
Lignocellulose-derived porous phosphorus-doped carbon as advanced electrode for supercapacitors
NASA Astrophysics Data System (ADS)
Yi, Jianan; Qing, Yan; Wu, ChuTian; Zeng, Yinxiang; Wu, Yiqiang; Lu, Xihong; Tong, Yexiang
2017-05-01
Engineering porous heteroatom-doped carbon nanomaterials with remarkable capacitive performance is highly attractive. Herein, a simple and smart method has been developed to synthesize phosphorus (P) doped carbon with hierarchical porous structure derived from lignocellulose. Hierarchically porous P doped carbon is readily obtained by the pyrolysis of lignocellulose immersed in ZnCl2/NaH2PO4 aqueous solution, and exhibits excellent capacitive properties. The as-obtained P doped porous carbon delivers a significant capacitance of 133 F g-1 (146 mF cm-2) at a high current density of 10 A g-1 with outstanding rate performance. Furthermore, the P doped carbon electrode yields a long-term cycling durability with more than 97.9% capacitance retention after 10000 cycles as well. A symmetric supercapacitor with a maximum energy density of 4.7 Wh kg-1 is also demonstrated based on these P doped carbon electrodes.
Stretched Lens Array Photovoltaic Concentrator Technology Developed
NASA Technical Reports Server (NTRS)
Piszczor, Michael F., Jr.; O'Neill, Mark J.
2004-01-01
Solar arrays have been and continue to be the mainstay in providing power to nearly all commercial and government spacecraft. Light from the Sun is directly converted into electrical energy using solar cells. One way to reduce the cost of future space power systems is by minimizing the size and number of expensive solar cells by focusing the sunlight onto smaller cells using concentrator optics. The stretched lens array (SLA) is a unique concept that uses arched Fresnel lens concentrators to focus sunlight onto a line of high-efficiency solar cells located directly beneath. The SLA concept is based on the Solar Concentrator Array with Refractive Linear Element Technology (SCARLET) design that was used on NASA's New Millennium Deep Space 1 mission. The highly successful asteroid/comet rendezvous mission (1998 to 2001) demonstrated the performance and long-term durability of the SCARLET/SLA solar array design and set the foundation for further improvements to optimize its performance.
Chen, Shuo; Liu, Xuemei; Qiao, Xvsheng; Wan, Xia; Shehzad, Khurram; Zhang, Xianghua; Xu, Yang; Fan, Xianping
2017-05-01
An effective colloidal process involving the hot-injection method is developed to synthesize uniform nanoflowers consisting of 2D γ-In 2 Se 3 nanosheets. By exploiting the narrow direct bandgap and high absorption coefficient in the visible light range of In 2 Se 3 , a high-quality γ-In 2 Se 3 /Si heterojunction photodiode is fabricated. This photodiode shows a high photoresponse under light illumination, short response/recovery times, and long-term durability. In addition, the γ-In 2 Se 3 /Si heterojunction photodiode is self-powered and displays a broadband spectral response ranging from UV to IR with a high responsivity and detectivity. These excellent performances make the γ-In 2 Se 3 /Si heterojunction very interesting as highly efficient photodetectors. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Examining the Effect of the Die Angle on Tool Load and Wear in the Extrusion Process
NASA Astrophysics Data System (ADS)
Nowotyńska, Irena; Kut, Stanisław
2014-04-01
The tool durability is a crucial factor in each manufacturing process, and this also includes the extrusion process. Striving to achieve the higher product quality should be accompanied by a long-term tool life and production cost reduction. This article presents the comparative research of load and wear of die at various angles of working cone during the concurrent extrusion. The numerical calculations of a tool load during the concurrent extrusion were performed using the MSC MARC software using the finite element method (FEM). Archard model was used to determine and compare die wear. This model was implemented in the software using the FEM. The examined tool deformations and stress distribution were determined based on the performed analyses. The die wear depth at various working cone angles was determined. Properly shaped die has an effect on the extruded material properties, but also controls loads, elastic deformation, and the tool life.
Chapter 10.2: Encapsulant Materials for PV Modules
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kempe, Michael D
2017-01-07
Encapsulant materials used in photovoltaic (PV) modules serve multiple purposes; it provides optical coupling of PV cells and protection against environmental stress. Polymers must perform these functions under prolonged periods of high temperature, humidity, and UV radiation. When PV panels were first developed in the 1960s and the 1970s, the dominant encapsulants were based on polydimethyl siloxane (PDMS). Ethylene-co-vinyl acetate (EVA) is currently the dominant encapsulant chosen for PV applications, not because it has the best combination of properties, but because it is an economical option with an established history of acceptable durability. Getting new products onto the market ismore » challenging because there is no room for dramatic improvements, and one must balance the initial cost and performance with the unknowns of long-term service life. Recently, there has been renewed interest in using alternative encapsulant materials with some significant manufacturers switching from EVA to polyolefin elastomer-based (POE) alternatives.« less
Sperk, Maike; Zhang, Wang; Nowak, Piotr; Neogi, Ujjwal
2018-02-01
Acute human immunodeficiency virus (HIV) infection is associated with a marked induction of several pathways that are linked to inflammation and CD4 T-cell depletion. Many of these processes do not fully resolve on short-term combination antiretroviral therapy (cART) (<5 years), despite complete and durable suppression of viremia. The effects of long-term (>15 years) successful antiretroviral therapy (ART) and the linkage between levels of biomarkers remain unclear. Therefore, the present study aims to assess the host plasma proteome in a well-defined clinical material from HIV-1-positive male patients on successful long-term ART (>15 years) and compared them with age-matched healthy controls and treatment-naïve male patients with viremia in a cross-sectional manner.Plasma samples were obtained from 3 categories of age-matched HIV-1-positive male patients on long-term successfully (ART, n = 10) with a median (Interquartile range, IQR) of 19 (17-20) years, treatment-naïve patients with viremia (VP, n = 14), and HIV-1-negative persons (HC, n = 11). Plasma proteome was analyzed using the proximity extension assay targeting 92 factors. Statistical analyses were performed with GraphPad Prism v7, R-packages, and Qlucore Omics Explorer v3.2. Functional enrichment analysis was performed by Kyoto Encyclopedia of Genes and Genomes (KEGG), and interactions of specific molecules were identified using Path Designer integrated into Ingenuity Pathway Analysis (IPA).Group wise comparison identified 53 soluble factors, which differed between the groups (P < .05). Cluster analysis identified 13 discrete soluble factors (CD8A, CRTAM, CXCL13, EGF, CD5, CD40, CXCL9, Gal-1, IL12RB1, KLRD1, PD-1, CASP-8 and TNFRSF9) between the studied groups (adjusted P < .001). The long-term successfully ART-treated individuals clustered and networked with the HC while VPs clustered separately. All of the proinflammatory cytokines and chemokines were normalized back to levels of healthy controls in long-term successfully ART-treated individuals, but not the levels of KLRD1 and PGDFB.sKLRD1 that is involved in the regulation of natural killer cell (NK) mediated cytotoxicity, failed to be restored to the level of HIV-negative individuals despite successful long-term ART. Additional analysis of NK cells along with T-cell subsets can provide insights into the long-term effects of ART on the immune system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, A.; McCormick, R.; Luecke, J.
2011-04-01
An accelerated durability test method determined the potential impact of biodiesel ash impurities, including engine testing with multiple diesel particulate filter substrate types, as well as diesel oxidation catalyst and selective catalyst reduction catalysts. The results showed no significant degradation in the thermo-mechanical properties of a DPF after exposure to 150,000-mile equivalent biodiesel ash and thermal aging. However, exposure to 435,000-mile equivalent aging resulted in a 69% decrease in thermal shock resistance. A decrease in DOC activity was seen after exposure to 150,000-mile equivalent aging, resulting in higher hydrocarbon slip and a reduction in NO2 formation. The SCR catalyst experiencedmore » a slight loss in activity after exposure to 435,000-mile equivalent aging. The SCR catalyst, placed downstream of the DPF and exposed to B20 exhaust suffered a 5% reduction in overall NOx conversion activity over the HDDT test cycle. It is estimated that the additional ash from 150,000 miles of biodiesel use would also result in a moderate increases in exhaust backpressure for a DPF. The results of this study suggest that long-term operation with B20 at the current specification limits for alkali and alkaline earth metal impurities will adversely impact the performance of DOC, DPF and SCR systems.« less
Perovskite solar cells: from materials to devices.
Jung, Hyun Suk; Park, Nam-Gyu
2015-01-07
Perovskite solar cells based on organometal halide light absorbers have been considered a promising photovoltaic technology due to their superb power conversion efficiency (PCE) along with very low material costs. Since the first report on a long-term durable solid-state perovskite solar cell with a PCE of 9.7% in 2012, a PCE as high as 19.3% was demonstrated in 2014, and a certified PCE of 17.9% was shown in 2014. Such a high photovoltaic performance is attributed to optically high absorption characteristics and balanced charge transport properties with long diffusion lengths. Nevertheless, there are lots of puzzles to unravel the basis for such high photovoltaic performances. The working principle of perovskite solar cells has not been well established by far, which is the most important thing for understanding perovksite solar cells. In this review, basic fundamentals of perovskite materials including opto-electronic and dielectric properties are described to give a better understanding and insight into high-performing perovskite solar cells. In addition, various fabrication techniques and device structures are described toward the further improvement of perovskite solar cells. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Erosion Resistant Coatings for Polymer Matrix Composites in Propulsion Applications
NASA Technical Reports Server (NTRS)
Sutter, James K.; Naik, Subhash K.; Horan, Richard; Miyoshi, Kazuhisa; Bowman, Cheryl; Ma, Kong; Leissler, George; Sinatra, Raymond; Cupp, Randall
2003-01-01
Polymer Matrix Composites (PMCs) offer lightweight and frequently low cost alternatives to other materials in many applications. High temperature PMCs are currently used in limited propulsion applications replacing metals. Yet in most cases, PMC propulsion applications are not in the direct engine flow path since particulate erosion degrades PMC component performance and therefore restricts their use in gas turbine engines. This paper compares two erosion resistant coatings (SANRES and SANPRES) on PMCs that are useful for both low and high temperature propulsion applications. Collaborating over a multi-year period, researchers at NASA Glenn Research Center, Allison Advanced Developed Company, and Rolls-Royce Corporation have optimized these coatings in terms of adhesion, surface roughness, and erosion resistance. Results are described for vigorous hot gas/particulate erosion rig and engine testing of uncoated and coated PMC fan bypass vanes from the AE 3007 regional jet gas turbine engine. Moreover, the structural durability of these coatings is described in long-term high cycle fatigue tests. Overall, both coatings performed well in all tests and will be considered for applications in both commercial and defense propulsion applications.
Space environment durability of beta cloth in LDEF thermal blankets
NASA Technical Reports Server (NTRS)
Linton, Roger C.; Whitaker, Ann F.; Finckenor, Miria M.
1993-01-01
Beta cloth performance for use on long-term space vehicles such as Space Station Freedom (S.S. Freedom) requires resistance to the degrading effects of the space environment. The major issues are retention of thermal insulating properties through maintaining optical properties, preserving mechanical integrity, and generating minimal particulates for contamination-sensitive spacecraft surfaces and payloads. The longest in-flight test of beta cloth's durability was on the Long Duration Exposure Facility (LDEF), where it was exposed to the space environment for 68 months. The LDEF contained 57 experiments which further defined the space environment and its effects on spacecraft materials. It was deployed into low-Earth orbit (LEO) in Apr. 1984 and retrieved Jan. 1990 by the space shuttle. Among the 10,000 plus material constituents and samples onboard were thermal control blankets of multilayer insulation with a beta cloth outer cover and Velcro attachments. These blankets were exposed to hard vacuum, thermal cycling, charged particles, meteoroid/debris impacts, ultraviolet (UV) radiation, and atomic oxygen (AO). Of these space environmental exposure elements, AO appears to have had the greatest effect on the beta cloth. The beta cloth analyzed in this report came from the MSFC Experiment S1005 (Transverse Flat-Plate Heat Pipe) tray oriented approximately 22 deg from the leading edge vector of the LDEF satellite. The location of the tray on LDEF and the placement of the beta cloth thermal blankets are shown. The specific space environment exposure conditions for this material are listed.
Long-Term Outcome of the Sorin Freedom SOLO Stentless Aortic Valve.
Christ, Torsten; Claus, Benjamin; Zielinski, Christina; Falk, Volkmar; Grubitzsch, Herko
2016-11-01
The Sorin Freedom SOLO valve is a third-generation stentless aortic valve which shows beneficial hemodynamic performance compared to stented bioprostheses. Long-term results regarding hemodynamics, the durability of the valve, and patient outcome are scarce, and their acquisition was the aim of this single-center study. Between 2005 and 2006, a total of 68 consecutive patients (30 males, 38 females; mean age at surgery 76.1 ± 6.3 years) underwent aortic valve replacement with a Sorin Freedom SOLO prosthesis. Indications were aortic stenosis (n = 50), aortic regurgitation (n = 1) and mixed lesions (n = 17). Associated procedures were performed in 31 patients (45.6%), most of which were coronary artery bypass grafting (68.8 %). The follow up was performed by telephone interviews, and clinical and echocardiographic examinations. Morbidity, mortality and echocardiographic data were analyzed. The total follow up was 501.1 patient-years, with a mean follow up of 7.4 ± 3.4 years (maximum 11.2 years). The follow up was 100% complete. Hospital mortality was 4.4% (n = 3). Actuarial survival at five and 10 years was 76.5 ± 5.1% and 41.5 ± 6.5%, respectively. Reinterventions were performed in eight patients; these included three reoperations due to endocarditis, four transcatheter aortic valve implantations, and one reoperation due to structural valve deterioration (SVD). The overall freedom from valve reintervention due to SVD at five and 10 years was 97.8 ± 2.2% and 82.9 ± 7.5%, respectively. After eight years, echocardiography demonstrated peak and mean transvalvular gradients of 18 ± 11 and 10 ± 7 mmHg, respectively. The overall effective and indexed aortic valve orifice areas were 1.73 ± 0.58 cm2 and 0.92 ± 0.33 cm2/m2, respectively. At long-term follow up the Sorin Freedom SOLO bioprosthesis was associated with favourable hemodynamic results and survival. Freedom from SVD was not superior to that occurring with stented bioprostheses.
Thymidine analogue-sparing highly active antiretroviral therapy (HAART).
Nolan, David; Mallal, Simon
2003-02-01
The use of alternative nucleoside reverse transcriptase inhibitors (NRTIs) to the thymidine analogues stavudine (d4T) and zidovudine(ZDV) has been advocated as a means of limiting long-term NRTI-associated toxicity, particularly the development of lipoatrophy or fat wasting. This approach reflects an increasing knowledge of the distinct toxicity profiles of NRTI drugs. However, recent clinical trials have demonstrated that the use of thymidine analogue NRTIs and newer alternative backbone NRTIs, such as tenofovir (TNF) and abacavir (ABC), is associated with comparable short-term efficacy and tolerability. Given the importance of toxicity profile differences in determining clinical management, it is important to recognise that d4T and ZDV cary significantly different risks for long-term NRTI toxicity. Recognising that all NRTIs, including thymidine analogues, have individual toxicity profiles provides a more appropriate basis for selecting optimal antiretroviral therapy. The safety and efficacy of TNF and ABC are also reviewed here, although the available data provide only limited knowledge of the long-term effects of these drugs in terms of toxicity and antiviral durability.
Evaluation of permanent deformation and durability of epoxidized natural rubber modified asphalt mix
NASA Astrophysics Data System (ADS)
Al-Mansob, Ramez A.; Ismail, Amiruddin; Rahmat, Riza Atiq O. K.; Nazri Borhan, Muhamad; Alsharef, Jamal M. A.; Albrka, Shaban Ismael; Rehan Karim, Mohamed
2017-09-01
The road distresses have caused too much in maintenance cost. However, better understandings of the behaviours and properties of asphalt, couples with greater development in technology, have allowed paving technologists to examine the benefits of introducing additives and modifiers. As a result, modifiers such as polymers are the most popular modifiers used to improve the performance of asphalt mix. This study was conducted to investigate the use of epoxidized natural rubber (ENR) to be mixed with asphalt mix. Tests were conducted to investigate the performance characteristics of ENR-asphalt mixes, where the mixes were prepared according to the wet process. Mechanical testing on the ENR-asphalt mixes have demonstrated that the asphalt mix permanent deformation performance at high temperature was found to be improved compared to the base mixes. However, the durability studies have indicated that ENR-asphalt mixes are slightly susceptible with the presence of moisture. The durability of the ENR-asphalt mixes were found to be enhanced in term of permanent deformation at high and intermediate temperatures compared to the base asphalt mixes. As conclusion, asphalt pavement performance can be enhanced by using ENR as modifier to face the major road distresses.
Durable Airtightness in Single-Family Dwellings - Field Measurementsand Analysis
Chan, Wanyu R.; Walker, Iain S.; Sherman, Max H.
2015-06-01
Here, durability of the building envelope is important to new homes that are increasingly built with improved levels of airtightness. It is also important to weatherized homes such that energy savings from retrofit measures, such as air sealing, are persistent. This paper presents a comparison of air leakage measurements collected in November 2013 through March 2014, with two sets of prior data collected between 2001-2003 from 17 new homes located near Atlanta, GA, and 17 homes near Boise, ID that were weatherized in 2007- 2008. The purpose of the comparison is to determine if there are changes to the airtightnessmore » of building envelopes over time. The air leakage increased in all but one of the new homes, with a mean increase of about 25%. The weatherized homes also showed an increase in the mean air leakage (12%). A regression analysis was performed to describe the relationship between prior and current measurements in terms of normalized leakage (NL). The best estimate of the ageing factor predicts a 15% increase in NL over ten years. Further analysis using ResDB data (LBNL’s Residential Diagnostic Database) showed the expected changes in air leakage if ageing were modelled. These results imply the need to examine the causes of increased leakage and methods to avoid them. This increase in leakage with time should be accounted for in long-term population-wide energy savings estimates, such as those used in ratings or energy savings programs.« less
Laparoscopic sleeve gastrectomy in Asia: Long term outcome and revisional surgery.
Pok, Eng-Hong; Lee, Wei-Jei; Ser, Kong-Han; Chen, Jung-Chien; Chen, Shu-Chun; Tsou, Ju-Juin; Chin, Kin-Fah
2016-01-01
Laparoscopic sleeve gastrectomy (LSG) is a popular stand-alone bariatric surgery, despite a paucity of long-term data. Hence, this study is to report the long-term outcome of LSG as primary bariatric procedure and the result of revisional surgery. With retrospective analysis of a prospective bariatric database, participants who defaulted clinic follow-up were interviewed by telephone. A total of 667 LSG was performed as primary bariatric procedure (2006-2012) with mean age of 34.5 ± 9.7 years old, female 74.7%, mean body mass index (BMI) 37.3 ± 8.1 kg/m(2). A 36-F bougie was used for all cases. There were 61 patients available with long-term data. The weight loss outcome at 1 year, 2 years, 3 years, 4 years, and 5 years showed a mean BMI 26.3, 25.2, 25.3, 27.1, and 26.2 with mean excess weight loss (EWL) 76.0%, 79.6%, 77.3%, 73.4%, and 72.6% respectively. However, 17% patients developed de novo gastro-esophageal reflux disease (GERD). Eighteen patients (2.2%) needed surgical revisions due to weight regain (n = 6), persistent type 2 diabetes mellitus (T2DM; n = 2), stricture (n = 2), and GERD (n = 8). The revision resulted in an additional mean excess weight loss of 23.8% with mean BMI 24.9 kg/m(2) at 6 months postoperatively. There was a 23.7% mean reduction of HbA1c with one patient who was in complete diabetic remission at 1 year. Our results showed LSG is a durable bariatric procedure with > 70% EWL at 5 years despite a high incidence of GERD. The need for revision of LSG is low and mainly for GERD. Copyright © 2015. Published by Elsevier Taiwan.
Gosain, Sonia; Mercer, Kim; Twaddell, William S; Uradomo, Lance; Greenwald, Bruce D
2013-08-01
Liquid nitrogen endoscopic spray cryotherapy can safely and effectively eradicate high-grade dysplasia in Barrett's esophagus (BE-HGD). Long-term data on treatment success and safety are lacking. To assess the long-term safety and efficacy of spray cryotherapy in patients with BE-HGD. Single-center, retrospective study. Tertiary-care referral center. A total of 32 patients with BE-HGD of any length. Patients were treated with liquid nitrogen spray cryotherapy every 8 weeks until complete eradication of HGD (CE-HGD) and intestinal metaplasia (CE-IM) was found by endoscopic biopsy. Surveillance endoscopy with biopsies was performed for at least 2 years. CE-HGD, CE-IM, durability of response, disease progression, and adverse events. CE-HGD was 100% (32/32), and CE-IM was 84% (27/32) at 2-year follow-up. At last follow-up (range 24-57 months), CE-HGD was 31/32 (97%), and CE-IM was 26/32 (81%). Recurrent HGD was found in 6 (18%), with CE-HGD in 5 after repeat treatment. One patient progressed to adenocarcinoma, downgraded to HGD after repeat cryotherapy. BE segment length ≥3 cm was associated with a higher recurrence of IM (P = .004; odds ratio 22.6) but not HGD. No serious adverse events occurred. Stricture was seen in 3 patients (9%), all successfully dilated. Retrospective study design, small sample size. In patients with BE-HGD, liquid nitrogen spray cryotherapy has an acceptable safety profile and success rate for eliminating HGD and IM and is associated with a low rate of recurrence or progression to cancer with long-term follow-up. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
[LONG TERM FOLLOW-UP OF TRANSCATHETER SELF EXPANDABLE AORTIC VALVE IMPLANTATION].
Chen, Shmuel; Zenios, Vicky; Gilon, Dan; Planer, David; Beeri, Ronen; Lotan, Chaim; Danenberg, Haim D
2018-03-01
Aortic stenosis is the most common significant valvular disease in the western world. These patients are treated operatively unless they are at high operative risk or inoperable. During the last decade an alternative approach has evolved - transcatheter aortic valve implantation (TAVI). This method was shown to be at least as effective and safe as the operative one. However, very little data exists on long term follow-up (5 years and above), especially regarding valve durability and patient survival. To present a long term follow-up on patients who underwent transcutaneous self-expandable aortic valve implantation in our department between the years 2008-2011. In September 2008 the first CoreValve implantation was performed in Israel at Hadassah Medical Center. All records of patients who were transplanted between 9.2008 and 10.2011 were reviewed. The function of the valve early after the procedure was compared to its function at the end of the follow-up period. A total of 38 patients (out of 71) survived at least 54 months, of them, 19 have an echocardiography examination at the end of the follow-up period. In all patients the implanted valve was found to function well at the end of the follow-up period, without significant stenosis or paravalvular leak. In fact, in approximately half of these patients, the degree of paravalvular leak decreased during the follow-up period. On long term (5 years) follow-up of patients who were implanted with the self-expandable aortic valve (CoreValve), no deterioration of the valve was observed. In fact, in approximately half of the patients, a decrease in the severity of the paravalvular leak was demonstrated.
Carney, John P; Zhang, Lindsey M; Larson, Jeffrey J; Lahti, Matthew T; Robinson, Nicholas A; Dalmasso, Agustin P; Bianco, Richard W
2017-07-01
Xenograft conduits have been used successfully to repair congenital heart defects, but are prone to failure over time. Hence, in order to improve patient outcomes, better xenografts are being developed. When evaluating a conduit's performance and safety it must first be compared against a clinically available control in a large animal model. The study aim was to evaluate a clinically available xenograft conduit used in right ventricular outflow tract (RVOT) reconstruction in a sheep model. RVOT reconstruction was performed in 13 adult and juvenile sheep, using the Medtronic Hancock® Bioprosthetic Valved Conduit (Hancock conduit). The method had previously been used on patients, and a newly modified variant termed 'RVOT Extraction' was employed to facilitate the surgical procedure. Animals were monitored over predetermined terms of 70 to 140 days. Serial transthoracic echocardiography, intracardiac pressure measurements and angiography were performed. On study completion the animals were euthanized and necropsies performed. Two animals died prior to their designated study term due to severe valvular stenosis and distal conduit narrowing, respectively. Thus, 11 animals survived the study term, with few or no complications. Generally, maximal and mean transvalvular pressure gradients across the implanted conduits were increased throughout the postoperative course. Among 11 full-term animals, seven conduits were patent with mild or no pseudointimal proliferation and with flexible leaflets maintaining the hemodynamic integrity of the valve. RVOT reconstruction using the Hancock conduit was shown to be successful in sheep, with durable and efficient performances. With its extensive clinical use in patients, and ability for long-term use in sheep (as described in the present study) it can be concluded that the Hancock conduit is an excellent control device for the evaluation of new xenografts in future preclinical studies.
Meniscus repair: the role of accelerated rehabilitation in return to sport.
Kozlowski, Erick J; Barcia, Anthony M; Tokish, John M
2012-06-01
With increasing understanding of the detrimental effects of the meniscectomized knee on outcomes and long-term durability, there is an ever increasing emphasis on meniscal preservation through repair. Repair in the young athlete is particularly challenging given the goals of returning to high-level sports. A healed meniscus is only the beginning of successful return to activity, and the understanding of "protection with progression" must be emphasized to ensure optimal return to performance. The principles of progression from low to high loads, single to multiplane activity, slow to high speeds, and stable to unstable platforms are cornerstones to this process. Emphasis on the kinetic chain environment that the knee will function within cannot be overemphasized. Communication between the operating surgeon and rehabilitation specialist is critical to optimizing effective return to sports.
Transoral incisionless fundoplication: current status.
Sami Trad, Karim
2016-07-01
Transoral incisionless fundoplication (TIF) performed with the EsophyX device (Redmond, Washington, USA) is a totally endoscopic procedure with the objectives to mechanically repair a defective gastroesophageal valve and to reduce small hiatal hernias. The recent publication of randomized controlled trials and long-term follow-up data offers the opportunity to reevaluate this treatment modality and its role in the management of patients with chronic gastroesophageal reflux disease (GERD). Randomized controlled trials have confirmed the ability of TIF to eliminate troublesome GERD symptoms, heal esophagitis, and improve distal esophageal acid exposure in appropriately selected patient populations. These studies establish TIF's superiority to conventional medical therapy, especially in clinical scenarios where proton-pump inhibitors fail to provide complete symptom relief across the spectrum of classic and atypical GERD manifestations, including regurgitation and laryngopharyngeal reflux. Long-term data indicate sustained positive outcomes and durability up to 6 years after procedure. These results were achieved with a low rate of serious adverse events and usually without introducing troublesome dysphagia, gas bloat, or flatulence. Based on the most recent data, TIF appears to be a valuable treatment alternative for the management of appropriately selected patients with moderate to severe chronic GERD symptoms.
NASA PS304 Lubricant Tested in World's First Commercial Oil-Free Gas Turbine
NASA Technical Reports Server (NTRS)
Weaver, Harold F.
2003-01-01
In a marriage of research and commercial technology, a 30-kW Oil-Free Capstone microturbine electrical generator unit has been installed and is serving as a test bed for long-term life-cycle testing of NASA-developed PS304 shaft coatings. The coatings are used to reduce friction and wear of the turbine engine s foil air bearings during startup and shut down when sliding occurs, prior to the formation of a lubricating air film. This testing supports NASA Glenn Research Center s effort to develop Oil-Free gas turbine aircraft propulsion systems, which will employ advanced foil air bearings and NASA s PS304 high temperature solid lubricant to replace the ball bearings and lubricating oil found in conventional engines. Glenn s Oil-Free Turbomachinery team s current project is the demonstration of an Oil-Free business jet engine. In anticipation of future flight certification of Oil-Free aircraft engines, long-term endurance and durability tests are being conducted in a relevant gas turbine environment using the Capstone microturbine engine. By operating the engine now, valuable performance data for PS304 shaft coatings and for industry s foil air bearings are being accumulated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, J.H.; Roy, D.M.; Mann, B.
1995-12-31
This paper describes an integrated approach to developing a predictive computer model for long-term performance of concrete engineered barriers utilized in LLRW and ILRW disposal facilities. The model development concept consists of three major modeling schemes: hydration modeling of the binder phase, pore solution speciation, and transport modeling in the concrete barrier and service environment. Although still in its inception, the model development approach demonstrated that the chemical and physical properties of complex cementitious materials and their interactions with service environments can be described quantitatively. Applying the integrated model development approach to modeling alkali (Na and K) leaching from amore » concrete pad barrier in an above-grade tumulus disposal unit, it is predicted that, in a near-surface land disposal facility where water infiltration through the facility is normally minimal, the alkalis control the pore solution pH of the concrete barriers for much longer than most previous concrete barrier degradation studies assumed. The results also imply that a highly alkaline condition created by the alkali leaching will result in alteration of the soil mineralogy in the vicinity of the disposal facility.« less
ERIC Educational Resources Information Center
Bache, William; Nauta, Marrit J.
This paper provides a summary of a Home Start Followup Study (HSFS) which was initiated in 1976. An attempt was made to examine the durability of gains made as the result of families' (parents and their 3- to 5-year-old children) participation in the program. In addition, the study was designed to determine whether program duration (one versus two…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Freeman, W.R.
1999-04-22
The project was a joint research effort between the U. S. Department of Energy's (DOE) Kansas City Plant (KCP) and Brandon Research, Inc. to develop ways to improve implants used for orthopedic surgery for joint replacement. The primary product produced by this study is design information, which may be used to develop implants that will improve long-term fixation and durability in the host bone environment.
Evolution of Force Sensing Technologies.
Shah, Dipen
2017-06-01
In order to Improve the procedural success and long-term outcomes of catheter ablation techniques for atrial fibrillation (AF), an Important unfulfilled requirement is to create durable electrophysiologically complete lesions. Measurement of contact force (CF) between the catheter tip and the target tissue can guide physicians to optimise both mapping and ablation procedures. Contact force can affect lesion size and clinical outcomes following catheter ablation of AF. Force sensing technologies have matured since their advent several years ago, and now allow the direct measurement of CF between the catheter tip and the target myocardium in real time. In order to obtain complete durable lesions, catheter tip spatial stability and stable contact force are important. Suboptimal energy delivery, lesion density/contiguity and/or excessive wall thickness of the pulmonary vein-left atrial (PV-LA) junction may result in conduction recovery at these sites. Lesion assessment tools may help predict and localise electrical weak points resulting in conduction recovery during and after ablation. There is increasing clinical evidence to show that optimal use of CF sensing during ablation can reduce acute PV re-conduction, although prospective randomised studies are desirable to confirm long-term favourable clinical outcomes. In combination with optimised lesion assessment tools, contact force sensing technology has the potential to become the standard of care for all patients undergoing AF catheter ablation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1982-09-01
The U.S. Department of Energy (DOE) is considering the selection of a strategy for the long-term management of the defense high-level wastes at the Idaho Chemical Processing Plant (ICPP). This report describes the environmental impacts of alternative strategies. These alternative strategies include leaving the calcine in its present form at the Idaho National Engineering Laboratory (INEL), or retrieving and modifying the calcine to a more durable waste form and disposing of it either at the INEL or in an offsite repository. This report addresses only the alternatives for a program to manage the high-level waste generated at the ICPP. 24more » figures, 60 tables.« less
Long-term hydrogen oxidation catalysts in alkaline fuel cells
NASA Astrophysics Data System (ADS)
Kiros, Y.; Schwartz, S.
Pt/Pd bimetallic combination and Raney Ni catalysts were employed in long-term electrochemical assessment of the hydrogen oxidation reaction (HOR) in 6 M KOH. Steady-state current vs. potential measurements of the gas diffusion electrodes have shown high activity for these types of catalysts. Durability tests of the electrodes have shown increased stability for the Pt/Pd-based catalysts than the Raney Ni at a constant load of 100 mA/cm 2 and at temperatures of 55°C and 60°C, respectively. Surface, structural and chemical analyses by BET surface area, transmission electron microscopy (TEM) and energy dispersive spectroscopy (EDS) were used to characterize the composite electrode/catalyst both before and after the electrochemical testing.
Understanding and managing conservation conflicts.
Redpath, Steve M; Young, Juliette; Evely, Anna; Adams, William M; Sutherland, William J; Whitehouse, Andrew; Amar, Arjun; Lambert, Robert A; Linnell, John D C; Watt, Allan; Gutiérrez, R J
2013-02-01
Conservation conflicts are increasing and need to be managed to minimise negative impacts on biodiversity, human livelihoods, and human well-being. Here, we explore strategies and case studies that highlight the long-term, dynamic nature of conflicts and the challenges to their management. Conflict management requires parties to recognise problems as shared ones, and engage with clear goals, a transparent evidence base, and an awareness of trade-offs. We hypothesise that conservation outcomes will be less durable when conservationists assert their interests to the detriment of others. Effective conflict management and long-term conservation benefit will be enhanced by better integration of the underpinning social context with the material impacts and evaluation of the efficacy of alternative conflict management approaches. Copyright © 2012 Elsevier Ltd. All rights reserved.
Khan, Sikandar Z; Rivero, Mariel; Cherr, Gregory S; Harris, Linda M; Dryjski, Maciej L; Dosluoglu, Hasan H
2018-05-15
Infrainguinal revascularization for disabling claudication (DC) is frequently performed, but long-term results are still unknown. In this study, we compared clinical outcomes of infrainguinal endovascular (EV) and open interventions for DC after the failure of medical management. One hundred ninety-four patients with DC (Rutherford category 3) who had open (n = 53) or EV (n = 141) interventions were grouped as open-great saphenous vein (GSV) (n = 21), open-prosthetic (n = 32), EV-Trans-Atlantic Inter-Society Consensus II (TASC II) A and B (AB) (n = 48), and EV-TASC II C and D (CD) (n = 93). Patency, primary clinical success (PCS; sustained improvement in symptoms without reintervention), and secondary clinical success (SCS; sustained improvement in symptoms with reintervention) rates were compared. Mean follow-up was 57 ± 33 months. Five-year primary patency was 58% in open-GSV, 40% in open-prosthetic, 72% in EV-AB, and 38% in EV-CD (P < 0.001). Five-year secondary patency was 77% in open-GSV, 50% in open-prosthetic, 96% in EV-AB, and 61% in EV-CD (P < 0.001). Freedom from major adverse limb events was 73% in open-GSV, 77% in EV-AB, 70% in EV-CD, and 67% in open-prosthetic (P = 0.279). Five-year PCS was 46% in open-GSV, 40% in open-prosthetic, 57% in EV-AB, and 44% in EV-CD (P = 0.02). Five-year SCS was 78% in open-GSV, 78% in open-prosthetic, 85% in EV-AB, and 84% in EV-CD (P = 0.732). A total of 116 reinterventions were performed, 10 in 6 limbs (27%) in open-GSV, 18 in 12 limbs (36%) in open-prosthetic, 26 in 15 limbs (24%) in EV-AB, and 62 in 39 limbs (36%) in EV-CD. Reinterventions included 71 (61%) EV and 45 (39%) open procedures. Durability of infrainguinal interventions in claudicants depends mainly on anatomic complexity of disease. Good long-term clinical success can be achieved with both open and EV interventions, albeit with high reintervention rates, especially in patients with TASC II C and D disease. A considerable subset of EV patients will eventually require surgical revascularization to maintain clinical benefit. In this study, almost 20% of patients undergoing EV for TASC II C and D disease eventually required surgical bypass. Copyright © 2018 Elsevier Inc. All rights reserved.
Long-term tolerance to kidney allografts in a preclinical canine model.
Kuhr, Christian S; Yunusov, Murad; Sale, George; Loretz, Carol; Storb, Rainer
2007-08-27
Durable immune tolerance supporting vascularized allotransplantation offers the possibility of extending graft survival and avoiding harmful complications of chronic immunosuppression. Immune tolerance to renal allografts was induced in a preclinical canine model through engraftment of donor hematopoietic cells using a combination of low-dose total body irradiation and a short course of immunosuppression. Subsequently, donor renal allografts were transplanted accompanied by bilateral native nephrectomies. With 5-year follow up, we found normal renal function in all recipients and no histological evidence of acute or chronic rejection. This tolerance does not extend universally to donor skin grafts, however, with two of four animals rejecting delayed donor skin grafts. Hematopoietic chimerism produces durable and robust immune tolerance to kidney allografts, although incomplete tolerance to donor skin grafting.
Advanced Oxide Material Systems For 1650 C Thermal/Environmental Barrier Coating Applications
NASA Technical Reports Server (NTRS)
Zhu, Dongming; Fox, Dennis S.; Bansal, Narottam P.; Miller, Robert A.
2004-01-01
Advanced thermal/environmental barrier coatings (T/EBCs) are being developed for low emission SiC/SiC ceramic matrix composite (CMC) combustor and vane applications to extend the CMC liner and vane temperature capability to 1650 C (3000 F) in oxidizing and water-vapor containing combustion environments. The 1650 C T/EBC system is required to have better thermal stability, lower thermal conductivity, and improved sintering and thermal stress resistance than current coating systems. In this paper, the thermal conductivity, water vapor stability and cyclic durability of selected candidate zirconia-/hafnia-, pyrochlore- and magnetoplumbite-based T/EBC materials are evaluated. The test results have been used to downselect the T/EBC coating materials, and help demonstrate advanced 1650OC coatings feasibility with long-term cyclic durability.
Processing and Characterization of Thousand-Hour 500 C Durable 4H-SiC JFET Integrated Circuits
NASA Technical Reports Server (NTRS)
Spry, David J.; Neudeck, Philip G.; Chen, Liangyu; Lukco, Dorothy; Chang, Carl W.; Beheim, Glenn M.; Krasowski, Michael J.; Prokop, Norman F.
2016-01-01
This work reports fabrication and testing of integrated circuits (ICs) with two levels of interconnect that consistently achieve greater than 1000 hours of stable electrical operation at 500 C in air ambient. These ICs are based on 4H-SiC junction field effect transistor (JFET) technology that integrates hafnium ohmic contacts with TaSi2 interconnects and SiO2 and Si3N4 dielectric layers over 1-m scale vertical topology. Following initial burn-in, important circuit parameters remain stable for more than 1000 hours of 500 C operational testing. These results advance the technology foundation for realizing long-term durable 500 C ICs with increased functional capability for sensing and control combustion engine, planetary, deep-well drilling, and other harsh-environment applications.
Processing and Characterization of Thousand-Hour 500 C Durable 4H-SiC JFET Integrated Circuits
NASA Technical Reports Server (NTRS)
Spry, David J.; Neudeck, Philip G.; Chen, Liang-Yu; Lukco, Dorothy; Chang, Carl W.; Beheim, Glenn M.; Krasowski, Michael J.; Prokop, Norman F.
2016-01-01
This work reports fabrication and testing of integrated circuits (ICs) with two levels of interconnect that consistently achieve greater than 1000 hours of stable electrical operation at 500 C in air ambient. These ICs are based on 4H-SiC junction field effect transistor (JFET) technology that integrates hafnium ohmic contacts with TaSi2 interconnects and SiO2 and Si3N4 dielectric layers over approximately 1-micrometer scale vertical topology. Following initial burn-in, important circuit parameters remain stable for more than 1000 hours of 500 C operational testing. These results advance the technology foundation for realizing long-term durable 500 C ICs with increased functional capability for sensing and control combustion engine, planetary, deep-well drilling, and other harsh-environment applications.
Durability of bonds and clinical success of adhesive restorations
Carvalho, Ricardo M.; Manso, Adriana P.; Geraldeli, Saulo; Tay, Franklin R.; Pashley, David H.
2013-01-01
Resin-dentin bond strength durability testing has been extensively used to evaluate the effectiveness of adhesive systems and the applicability of new strategies to improve that property. Clinical effectiveness is determined by the survival rates of restorations placed in non-carious cervical lesions (NCCL). While there is evidence that the bond strength data generated in laboratory studies somehow correlates with the clinical outcome of NCCL restorations, it is questionable whether the knowledge of bonding mechanisms obtained from laboratory testing can be used to justify clinical performance of resin-dentin bonds. There are significant morphological and structural differences between the bonding substrate used in in vitro testing versus the substrate encountered in NCCL. These differences qualify NCCL as a hostile substrate for bonding, yielding bond strengths that are usually lower than those obtained in normal dentin. However, clinical survival time of NCCL restorations often surpass the durability of normal dentin tested in the laboratory. Likewise, clinical reports on the long-term survival rates of posterior composite restorations defy the relatively rapid rate of degradation of adhesive interfaces reported in laboratory studies. This article critically analyzes how the effectiveness of adhesive systems is currently measured, to identify gaps in knowledge where new research could be encouraged. The morphological and chemical analysis of bonded interfaces of resin composite restorations in teeth that had been in clinical service for many years, but were extracted for periodontal reasons, could be a useful tool to observe the ultrastructural characteristics of restorations that are regarded as clinically acceptable. This could help determine how much degradation is acceptable for clinical success. PMID:22192252
Development of Oxidation Protection Coatings for Gamma Titanium Aluminide Alloys
NASA Technical Reports Server (NTRS)
Wallace, T. A.; Bird, R. K.; Sankaran, S. N.
2003-01-01
Metallic material systems play a key role in meeting the stringent weight and durability requirements for reusable launch vehicle (RLV) airframe hot structures. Gamma titanium aluminides (gamma-TiAl) have been identified as high-payoff materials for high-temperature applications. The low density and good elevated temperature mechanical properties of gamma-TiAl alloys make them attractive candidates for durable lightweight hot structure and thermal protection systems at temperatures as high as 871 C. However, oxidation significantly degrades gamma-TiAl alloys under the high-temperature service conditions associated with the RLV operating environment. This paper discusses ongoing efforts at NASA Langley Research Center to develop durable ultrathin coatings for protecting gamma-TiAl alloys from high-temperature oxidation environments. In addition to offering oxidation protection, these multifunctional coatings are being engineered to provide thermal control features to help minimize heat input into the hot structures. This paper describes the coating development effort and discusses the effects of long-term high-temperature exposures on the microstructure of coated and uncoated gamma-TiAl alloys. The alloy of primary consideration was the Plansee alloy gamma-Met, but limited studies of the newer alloy gamma-Met-PX were also included. The oxidation behavior of the uncoated materials was evaluated over the temperature range of 704 C to 871 C. Sol-gel-based coatings were applied to the gamma-TiAl samples by dipping and spraying, and the performance evaluated at 871 C. Results showed that the coatings improve the oxidation resistance, but that further development is necessary.
Moisture Performance of High-R Wall Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shah, Nay B.; Kochkin, Vladimir
High-performance homes offer improved comfort, lower utility bills, and assured durability. The next generation of building enclosures is a key step toward achieving high-performance goals through decreasing energy load demand and enabling advanced space-conditioning systems. Yet the adoption of high-R enclosures and particularly high-R walls has been a slow-growing trend because mainstream builders are hesitant to make the transition. In a survey of builders on this topic, one of the challenges identifi ed is an industry-wide concern about the long-term moisture performance of energy-effi cient walls. This study takes a step toward addressing this concern through direct monitoring of themore » moisture performance of high-R walls in occupied homes in several climate zones. In addition, the robustness of the design and modeling tools for selecting high-R wall solutions is evaluated using the monitored data from the field. The information and knowledge gained through this research will provide an objective basis for decision-making so that builders can implement advanced designs with confidence.« less
Maurer, Tilman; Kuck, Karl-Heinz
2017-08-01
Atrial fibrillation is the most common cardiac arrhythmia and represents a growing clinical, social and economic challenge. Catheter ablation for symptomatic atrial fibrillation has evolved from an experimental procedure into a widespread therapy and offers a safe and effective treatment option. A prerequisite for durable PVI are transmural and contiguous circumferential lesions around the pulmonary veins. However, electrical reconnection of initially isolated pulmonary veins remains a primary concern and is a dominant factor for arrhythmia recurrence during long-term follow up. Areas covered: This article discusses the physiology of lesion formation using radiofrequency-, cryo- or laser- energy for pulmonary vein isolation and provides a detailed review of recent technological advancements in the field of radiofrequency catheters and balloon devices. Finally, future directions and upcoming developments for the interventional treatment of atrial fibrillation are discussed. Expert commentary: Durable conduction block across deployed myocardial lesions is mandatory not only for PVI but for any other cardiac ablation strategy as well. A major improvement urgently expected is the intraprocedural real-time distinction of durable lesions from interposed gaps with only transiently impaired electrical conduction. Furthermore, a simplification of ablation tools used for PVI is required to reduce the high technical complexity of the procedure.
Vlachojannis, Georgios J; Smits, Pieter C; Hofma, Sjoerd H; Togni, Mario; Vázquez, Nicolás; Valdés, Mariano; Voudris, Vassilis; Slagboom, Ton; Goy, Jean-Jaques; den Heijer, Peter; van der Ent, Martin
2017-06-26
This analysis investigates the 5-year outcomes of the biodegradable polymer biolimus-eluting stent (BP-BES) and durable polymer everolimus-eluting stent (DP-EES) in an all-comers population undergoing percutaneous coronary intervention. Recent 1- and 3-year results from randomized trials have indicated similar safety and efficacy outcomes of BP-BES and DP-EES. Whether benefits of the biodegradable polymer device arise over longer follow-up is unknown. Moreover, in-depth, prospective, long-term follow-up data on metallic drug-eluting stents with durable or biodegradable polymers are scarce. The COMPARE II trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent) was a prospective, randomized, multicenter, all-comers trial in which 2,707 patients were randomly allocated (2:1) to BP-BES or DP-EES. The pre-specified endpoint at 5 years was major adverse cardiac events, a composite of cardiac death, nonfatal myocardial infarction, or target vessel revascularization. Five-year follow-up was available in 2,657 patients (98%). At 5 years, major adverse cardiac events occurred in 310 patients (17.3%) in the BP-BES group and 142 patients (15.6%) in the DP-EES group (p = 0.26). The rate of the combined safety endpoint all-cause death or myocardial infarction was 15.0% in the BP-BES group versus 14.8% in the DP-EES group (p = 0.90), whereas the efficacy measure target vessel revascularization was 10.6% versus 9.0% (p = 0.18), respectively. Interestingly, definite stent thrombosis rates did not differ between groups (1.5% for BP-BES vs. 0.9% for DP-EES; p = 0.17). The 5-year analysis comparing biodegradable polymer-coated BES and the durable polymer-coated EES confirms the initial early- and mid-term results regarding similar safety and efficacy outcomes in this all-comers percutaneous coronary intervention population. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Zhu, Dongming
2014-01-01
Ceramic environmental barrier coatings (EBC) and SiCSiC ceramic matrix composites (CMCs) will play a crucial role in future aircraft propulsion systems because of their ability to significantly increase engine operating temperatures, improve component durability, reduce engine weight and cooling requirements. Advanced EBC systems for SiCSiC CMC turbine and combustor hot section components are currently being developed to meet future turbine engine emission and performance goals. One of the significant material development challenges for the high temperature CMC components is to develop prime-reliant, high strength and high temperature capable environmental barrier coating bond coat systems, since the current silicon bond coat cannot meet the advanced EBC-CMC temperature and stability requirements. In this paper, advanced NASA HfO2-Si based EBC bond coat systems for SiCSiC CMC combustor and turbine airfoil applications are investigated. The coating design approach and stability requirements are specifically emphasized, with the development and implementation focusing on Plasma Sprayed (PS) and Electron Beam-Physic Vapor Deposited (EB-PVD) coating systems and the composition optimizations. High temperature properties of the HfO2-Si based bond coat systems, including the strength, fracture toughness, creep resistance, and oxidation resistance were evaluated in the temperature range of 1200 to 1500 C. Thermal gradient heat flux low cycle fatigue and furnace cyclic oxidation durability tests were also performed at temperatures up to 1500 C. The coating strength improvements, degradation and failure modes of the environmental barrier coating bond coat systems on SiCSiC CMCs tested in simulated stress-environment interactions are briefly discussed and supported by modeling. The performance enhancements of the HfO2-Si bond coat systems with rare earth element dopants and rare earth-silicon based bond coats are also highlighted. The advanced bond coat systems, when integrated with advanced EBC top coats, showed promise to achieve 1500 C temperature capability, helping enable next generation turbine engines with significantly improved engine component temperature capability and long-term durability.
NASA Astrophysics Data System (ADS)
Chandrasekhar, Prasanna; Zay, Brian J.; Barbolt, Scott; Werner, Robert; Birur, Gajanana C.; Paris, Anthony
2009-03-01
This contribution describes the fabrication, function and performance of thin-film variable emittance electrochromic skins fabricated using poly(aniline) as the conducting polymer (CP), a long-chain polymeric dopant, and an ionic liquid as electrolyte. The ionic electrolyte allows operation in space vacuum without any seals. A unique, space-durable coating applied to the external surface of the skins drastically lowers the solar absorptance of the skins, such that in their dark (highly emissive) electrochromic state, it is no more than 0.44, whilst in their light electrochromic state, it is ca. 0.3. Data presented show tailorable, variations from 0.19 to 0.90, ∀(s)<0.3, and nearly indefinite cyclability. Extended thermal vacuum, atomic-O, micrometeoroid, VUV and other studies show excellent space durability. Performance of a doughnut-shaped skin designed for a specific micro-spacecraft is also described.
Pashapour, Ali; Mohammadian, Reza; Salehpour, Firooz; Sharifipour, Ehsan; Mansourizade, Reza; Mahdavifard, Ali; Salehi, Mohamadgharib; Mirzaii, Farhad; Sariaslani, Payam; Fatahzade Ardalani, Ghasem; Altafi, Davar
2014-01-01
Summary Ocular symptoms are regularly observed in patients with cavernous sinus dural arteriovenous fistulas (cDAVF). We aimed to evaluate the long-term efficacy and safety of endovascular approaches in patients with cDAVF presenting with different ocular symptoms. In a prospective study between June 2008 and March 2013, 46 patients with ocular symptoms due to cDAVF who were not eligible for conservative therapy, met the inclusion criteria and underwent endovascular treatment. They underwent a transarterial approach with histoacryl glue injections or transvenous coil embolization, all in one session. They were followed up for a mean period of 17.3 months (range 7 to 30 months) clinically and using angiography. The mean age of patients was 36.8 years (18-60) and 65% of them were male. All patients showed venous drainage into the superior and inferior orbital veins. Access to the cavernous sinus was transvenous in ten patients, transarterial in 26 patients, and mixed in ten patients. Initial symptoms were improved in 97.8% of patients and did not recur during the study follow-up. The procedural complications included: blurred vision, transient sixth nerve palsy and exacerbation of chemoproptosis in two, one and two patients respectively that completely resolved in initial weeks with no recurrence. No patient worsened or developed new symptoms suggestive of a recurrent fistula during the follow-up period. One patient experienced intracranial dissection of the internal carotid artery and ischemic stroke with an unfinished procedure. The relief of early presentation was durable in long-term follow-up and the cured lesions were stable in angiographic controls. Favorable and durable outcomes could be obtained following endovascular approaches for cDAVF presenting with different ocular symptoms. PMID:25196621
Stent Coating Integrity of Durable and Biodegradable Coated Drug Eluting Stents.
Yazdani, Saami K; Sheehy, Alexander; Pacetti, Stephen; Rittlemeyer, Brandon; Kolodgie, Frank D; Virmani, Renu
2016-10-01
Coatings consisting of a polymer and drug are widely used in drug-eluting stents (DES) and are essential in providing programmable drug release kinetics. Among other factors, stent coating technologies can influence blood compatibility, affect acute and sub-acute healing, and potentially trigger a chronic inflammatory response. The aim of this study was to investigate the short-term (7 and 28 days) and long-term (90 and 180 days) coating integrity of the Xience Prime Everolimus-Eluting Stent (EES), Resolute Zotarolimus-Eluting Stent (ZES), Taxus Paclitaxel-Eluting Stent (PES), and Nobori Biolimus A9-Eluting Stent (BES) in a rabbit ilio-femoral stent model. Stented arteries (n = 48) were harvested and the tissue surrounding the implanted stents digested away with an enzymatic solution. Results demonstrated that the majority of struts of EES were without any coating defects with a few struts showing minor defects. Similarly, for the ZES, most of the struts were without coating defects at all time points except at 180 days. The majority of PES demonstrated mostly webbing and uneven coating. In the BES group, the majority of strut coating showed polymer cracking. Overall, the EES and ZES had fewer coating defects than the PES and BES. Coating defects, however increase over time for the ZES, whereas the percent of coating irregularities remained constant for the EES. These results provide, for the first time, a comparison of the long-term durability of these drug-eluting stent coatings in vivo. © 2016, Wiley Periodicals, Inc.
Current indications for stentless aortic bioprostheses.
Hegazy, Yasser Y; Rayan, Amr; Bauer, Stefan; Keshk, Noha; Bauer, Kerstin; Ennker, Ina; Ennker, Jürgen
2018-01-01
The best aortic prostheses have been debated for decades. The introduction of stentless aortic bioprostheses was aimed at improving hemodynamics and potentially the durability of aortic bioprostheses. Despite the good short- and long-term outcomes after implantation of stentless aortic bioprostheses, their use remains limited owing to the technically demanding implantation techniques. Nevertheless, stentless aortic bioprostheses might be of special benefit in certain indications, where they could be a valuable addition to the surgical armamentarium.
2013-01-08
This re- search ignores effects on long-term durability, trafficability, temperature rebar corrosion , and other concerns that are of minimal... concrete because it can cause corrosion of steel reinforcement. However, the corrosion problem develops slowly with time; therefore, this problem has a...ER D C/ CR RE L TR -1 3- 1 Laboratory Evaluation of Expedient Low- Temperature Concrete Admixtures for Repairing Blast Holes in Cold
High-temperature durability considerations for HSCT combustor
NASA Technical Reports Server (NTRS)
Jacobson, Nathan S.
1992-01-01
The novel combustor designs for the High Speed Civil Transport will require high temperature materials with long term environmental stability. Higher liner temperatures than in conventional combustors and the need for reduced weight necessitates the use of advanced ceramic matrix composites. The combustor environment is defined at the current state of design, the major degradation routes are discussed for each candidate ceramic material, and where possible, the maximum use temperatures are defined for these candidate ceramics.
Laboratory Evaluation of Expedient Low-Temperature Admixtures for Runway Craters in Cold Weather
2014-10-01
ignores typical concerns, such as long-term durability, aesthetics, and corrosion , that are of minimal importance in this expedient field- use ...those identified to be in common use although it was acknowledged that the chloride based compounds caused corrosion problems (Korhonen 1990...batch to batch when using less than a 2000 lb batch, our ability to model and predict results with each batch is degraded. How- ever, when we control
DOE Office of Scientific and Technical Information (OSTI.GOV)
Storey, Robson, F.; Mauritz, Kenneth, A.; Patton, Derek, L.
The overall objective of this project was the development and evaluation of novel hydrocarbon fuel cell (FC) membranes that possess high temperature performance and long term chemical/mechanical durability in proton exchange membrane (PEM) fuel cells (FC). The major research theme was synthesis of aromatic hydrocarbon polymers of the poly(arylene ether sulfone) (PAES) type containing sulfonic acid groups tethered to the backbone via perfluorinated alkylene linkages and in some cases also directly attached to the phenylene groups along the backbone. Other research themes were the use of nitrogen-based heterocyclics instead of acid groups for proton conduction, which provides high temperature, lowmore » relative humidity membranes with high mechanical/thermal/chemical stability and pendant moieties that exhibit high proton conductivities in the absence of water, and synthesis of block copolymers consisting of a proton conducting block coupled to poly(perfluorinated propylene oxide) (PFPO) blocks. Accomplishments of the project were as follows: 1) establishment of a vertically integrated program of synthesis, characterization, and evaluation of FC membranes, 2) establishment of benchmark membrane performance data based on Nafion for comparison to experimental membrane performance, 3) development of a new perfluoroalkyl sulfonate monomer, N,N-diisopropylethylammonium 2,2-bis(p-hydroxyphenyl) pentafluoropropanesulfonate (HPPS), 4) synthesis of random and block copolymer membranes from HPPS, 5) synthesis of block copolymer membranes containing high-acid-concentration hydrophilic blocks consisting of HPPS and 3,3'-disulfonate-4,4'-dichlorodiphenylsulfone (sDCDPS), 6) development of synthetic routes to aromatic polymer backbones containing pendent 1H-1,2,3-triazole moieties, 7) development of coupling strategies to create phase-separated block copolymers between hydrophilic sulfonated prepolymers and commodity polymers such as PFPO, 8) establishment of basic performance properties of experimental membranes, 9) fabrication and FC performance testing of membrane electrode assemblies (MEA) from experimental membranes, and 10) measurement of ex situ and in situ membrane durability of experimental membranes. Although none of the experimental hydrocarbon membranes that issued from the project displayed proton conductivities that met DOE requirements, the project contributed to our basic understanding of membrane structure-property relationships in a number of key respects. An important finding of the benchmark studies is that physical degradation associated with humidity and temperature variations in the FC tend to open new fuel crossover pathways and act synergistically with chemical degradation to accelerate overall membrane degradation. Thus, for long term membrane survival and efficient fuel utilization, membranes must withstand internal stresses due to humidity and temperature changes. In this respect, rigid aromatic hydrocarbon fuel cell membranes, e.g. PAES, offer an advantage over un-modified Nafion membranes. The benchmark studies also showed that broadband dielectric spectroscopy is a potentially powerful tool in assessing shifts in the fundamental macromolecular dynamics caused by Nafion chemical degradation, and thus, this technique is of relevance in interrogating proton exchange membrane durability in fuel cells and macromolecular dynamics as coupled to proton migration, which is of fundamental relevance in proton exchange membranes in fuel cells. A key finding from the hydrocarbon membrane synthesis effort was that rigid aromatic polymers containing isolated ion exchange groups tethered tightly to the backbone (short tether), such as HPPS, provide excellent mechanical and durability properties but do not provide sufficient conductivity, in either random or block configuration, when used as the sole ion exchange monomer. However, we continue to hypothesize that longer tethers, and tethered groups spaced more closely within the hydrophilic chain elements of the polymer, will yield highly conductive materials with excellent mechanical properties. Another key finding is the superior performance of PAES membranes upon being subjected to open circuit voltage (OCV) testing. Throughout the course of the experiment, OCV for the PAES not only stayed higher but also decayed at a much lower rate, which is attributed to better dimensional stability and improved mechanical and gas barrier properties. The rigid backbone reinforcement of PAES adds gas diffusion tortuosity that restricts membrane degradation and OCV loss due to reduced fuel crossover. The overall results of creep, contractile stress and mechanical tensile tests confirm the conclusion that degraded MEAs of PAES membrane can handle stress and are more likely to be more durable in a fuel cell, even after subjected to 62h of OCV degradation.« less
Short-term and long-term attentional biases to frequently encountered target features.
Sha, Li Z; Remington, Roger W; Jiang, Yuhong V
2017-07-01
It has long been known that frequently occurring targets are attended better than infrequent ones in visual search. But does this frequency-based attentional prioritization reflect momentary or durable changes in attention? Here we observed both short-term and long-term attentional biases for visual features as a function of different types of statistical associations between the targets, distractors, and features. Participants searched for a target, a line oriented horizontally or vertically among diagonal distractors, and reported its length. In one set of experiments we manipulated the target's color probability: Targets were more often in Color 1 than in Color 2. The distractors were in other colors. Participants found Color 1 targets more quickly than Color 2 targets, but this preference disappeared immediately when the target's color became random in the subsequent testing phase. In the other set of experiments, we manipulated the diagnostic values of the two colors: Color 1 was more often a target than a distractor; Color 2 was more often a distractor than a target. Participants found Color 1 targets more quickly than Color 2 targets. Importantly, and in contrast to the first set of experiments, the featural preference was sustained in the testing phase. These results suggest that short-term and long-term attentional biases are products of different statistical information. Finding a target momentarily activates its features, inducing short-term repetition priming. Long-term changes in attention, on the other hand, may rely on learning diagnostic features of the targets.
Comparison of performance criteria for evaluating stake test data
Stan T. Lebow; Patricia K. Lebow; Grant T. Kirker
2017-01-01
Stake tests are a critical part of evaluating durability of wood in ground-contact, but there is a lack of criteria for interpreting stake test results. This paper discusses criteria that might be used to determine if short term ratings indicate satisfactory longterm performance. Ratings of 19 by 19 mm stakes from multiple plots in the Harrison Experimental Forest,...
The MISSE-9 Polymers and Composites Experiment Being Flown on the MISSE-Flight Facility
NASA Technical Reports Server (NTRS)
De Groh, Kim K.; Banks, Bruce A.
2017-01-01
Materials on the exterior of spacecraft in low Earth orbit (LEO) are subject to extremely harsh environmental conditions, including various forms of radiation (cosmic rays, ultraviolet, x-ray, and charged particle radiation), micrometeoroids and orbital debris, temperature extremes, thermal cycling, and atomic oxygen (AO). These environmental exposures can result in erosion, embrittlement and optical property degradation of susceptible materials, threatening spacecraft performance and durability. To increase our understanding of space environmental effects such as AO erosion and radiation induced embrittlement of spacecraft materials, NASA Glenn has developed a series of experiments flown as part of the Materials International Space Station Experiment (MISSE) missions on the exterior of the International Space Station (ISS). These experiments have provided critical LEO space environment durability data such as AO erosion yield values for many materials and mechanical properties changes after long term space exposure. In continuing these studies, a new Glenn experiment has been proposed, and accepted, for flight on the new MISSE-Flight Facility (MISSE-FF). This experiment is called the Polymers and Composites Experiment and it will be flown as part of the MISSE-9 mission, the inaugural mission of MISSE-FF. Figure 1 provides an artist rendition of MISSE-FF ISS external platform. The MISSE-FF is manifested for launch on SpaceX-13.
NASA Astrophysics Data System (ADS)
Rodríguez-Abad, Isabel; Klysz, Gilles; Martínez-Sala, Rosa; Balayssac, Jean Paul; Mené-Aparicio, Jesús
2016-12-01
The long-term performance of concrete structures is directly tied to two factors: concrete durability and strength. When assessing the durability of concrete structures, the study of the water penetration is paramount, because almost all reactions like corrosion, alkali-silica, sulfate, etc., which produce their deterioration, require the presence of water. Ground-penetrating radar (GPR) has shown to be very sensitive to water variations. On this basis, the objective of this experimental study is, firstly, to analyze the correlation between the water penetration depth in concrete samples and the GPR wave parameters. To do this, the samples were immersed into water for different time intervals and the wave parameters were obtained from signals registered when the antenna was placed on the immersed surface of the samples. Secondly, a procedure has been developed to be able to determine, from those signals, the reliability in the detection and location of waterfront depths. The results have revealed that GPR may have an enormous potential in this field, because excellent agreements were found between the correlated variables. In addition, when comparing the waterfront depths calculated from GPR measurements and those visually registered after breaking the samples, we observed that they totally agreed when the waterfront was more than 4 cm depth.
Transport properties of damaged materials. Cementitious barriers partnership
DOE Office of Scientific and Technical Information (OSTI.GOV)
Langton, C.
2014-11-01
The objective of the Cementitious Barriers Partnership (CBP) project is to develop tools to improve understanding and prediction of the long-term structural, hydraulic, and chemical performance of cementitious barriers used in low-level waste storage applications. One key concern for the long-term durability of concrete is the degradation of the cementitious matrix, which occurs as a result of aggressive chemical species entering the material or leaching out in the environment, depending on the exposure conditions. The objective of the experimental study described in this report is to provide experimental data relating damage in cementitious materials to changes in transport properties, whichmore » can eventually be used to support predictive model development. In order to get results within a reasonable timeframe and to induce as much as possible uniform damage level in materials, concrete samples were exposed to freezing and thawing (F/T) cycles. The methodology consisted in exposing samples to F/T cycles and monitoring damage level with ultrasonic pulse velocity measurements. Upon reaching pre-selected damage levels, samples were tested to evaluate changes in transport properties. Material selection for the study was motivated by the need to get results rapidly, in order to assess the relevance of the methodology. Consequently, samples already available at SIMCO from past studies were used. They consisted in three different concrete mixtures cured for five years in wet conditions. The mixtures had water-to-cement ratios of 0.5, 0.65 and 0.75 and were prepared with ASTM Type I cement only. The results showed that porosity is not a good indicator for damage caused by the formation of microcracks. Some materials exhibited little variations in porosity even for high damage levels. On the other hand, significant variations in tortuosity were measured in all materials. This implies that damage caused by internal pressure does not necessarily create additional pore space in the microstructure, but likely creates new thin pathways between existing pore space for species to travel. These results have a significant impact on modeling efforts. Models relating porosity to tortuosity and permeability are unlikely to provide the correct basis for predicting long-term durability of concrete sustaining internal pressures and microcrack formation. Other avenues like the modeling of internal crystallization pressure need to be explored.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Knights, Shanna; Harvey, David
The durability of PEM fuel cells is a primary requirement for large scale commercialization of these power systems in transportation and stationary market applications which target operational lifetimes of 5,000 hours and 60,000 hours by 2020, respectively. Key degradation modes contributing to fuel cell lifetime limitations have been largely associated with the platinum-based cathode catalyst layer. Furthermore, as fuel cells are driven to low cost materials and lower catalyst loadings in order to meet the cost targets for commercialization, the catalyst durability has become even more important. While over the past few years significant progress has been made in identifyingmore » the underlying causes of fuel cell degradation and key parameters that greatly influence the degradation rates, many gaps with respect to knowledge of the driving mechanisms still exist; in particular, the acceleration of the mechanisms due to different membrane compositions remains an area not well understood. The focus of this project extension was to enhance the predictive capability of the PEM Fuel Cell Performance & Durability Model called FC-APOLLO (Application Package for Open-source Long Life Operation) by including interaction effects of membrane transport properties such as water transport, changes in proton conductivity, and overall water uptake/adsorption and the state of the catalyst layer local conditions to further understand the driving forces for platinum dissolution.« less
Fundamental Investigations and Rational Design of Durable High-Performance SOFC Cathodes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Yu; Ding, Dong; Wei, Tao
The main objective of this project is to unravel the degradation mechanism of LSCF cathodes under realistic operating conditions with different types of contaminants, aiming towards the rational design of cathodes with high-performance and enhanced durability by combining a porous backbone (such as LSCF) with a thin catalyst coating. The mechanistic understanding will help us to optimize the composition and morphology of the catalyst layer and microstructure of the LSCF backbone for better performance and durability. More specifically, the technical objectives include: (1) to unravel the degradation mechanism of LSCF cathodes under realistic operating conditions with different types of contaminantsmore » using in situ and ex situ measurements performed on specially-designed cathodes; (2) to examine the microstructural and compositional evolution of LSCF cathodes as well as the cathode/electrolyte interfaces under realistic operating conditions; (3) to correlate the fuel cell performance instability and degradation with the microstructural and morphological evolution and surface chemistry change of the cathode under realistic operating conditions; (4) to explore new catalyst materials and electrode structures to enhance the stability of the LSCF cathode under realistic operating conditions; and (5) to validate the long term stability of the modified LSCF cathode in commercially available cells under realistic operating conditions. We have systematically evaluated LSCF cathodes in symmetrical cells and anode supported cells under realistic conditions with different types of contaminants such as humidity, CO 2, and Cr. Electrochemical models for the design of test cells and understanding of mechanisms have been developed for the exploration of fundamental properties of electrode materials. It is demonstrated that the activity and stability of LSCF cathodes can be degraded by the introduction of contaminants. The microstructural and compositional evolution of LSCF cathodes as well as the cathode/electrolyte interfaces under realistic operating conditions has been studied. It is found that SrO readily segregated/enriched on the LSCF surface. More severe contamination conditions cause more SrO on surface. Novel catalyst coatings through particle depositions (PrOx) or continuous thin films (PNM) were successfully developed to improve the activity and stability of LSCF cathodes. Finally, we have demonstrated enhanced activity and stability of LSCF cathodes over longer periods of time in homemade and commercially available cells by an optimized PNM (dense film and particles) infiltration process, under clean air and realistic operating conditions (3% H 2O, 5% CO 2 and direct Crofer contact). Both performance and durability of single cells with PNM coating has been enhanced compared with those without coating. Raman analysis of cathodes surface indicated that the intensity of SrCrO 4 was significantly decreased.« less
A 76-year old man with a torn Freedom SOLO bioprosthesis.
Wollersheim, Laurens W; Li, Wilson W; van der Meulen, Jan; de Mol, Bas A
2014-01-01
We describe a case of a 76-year old male who presented with progressive dyspnoea. He underwent an aortic valve replacement with a Freedom SOLO bioprosthesis 6 years ago. Transthoracic echocardiography showed a moderate-to-severe leakage of the Freedom SOLO bioprosthesis. During surgical reintervention, a partial tear of the left coronary cusp was seen from the commissure of the right coronary cusp to its base. After radiographic and microscopic examination, no clear cause was found for the failure of this Freedom SOLO bioprosthesis. To our knowledge, this is the third failure of a Freedom SOLO bioprosthesis reported in the literature. When the long-term follow-up of the Freedom SOLO bioprosthesis is available, it has to be compared with other bioprosthesis for long-term durability.
Shapey, I M; Agrawal, S; Peacock, A; Super, P
2015-01-01
Laparoscopic partial fundoplication for gastro-oesophageal reflux disease (GORD) is reported to have fewer side effects when compared to Nissen fundoplication, but doubts remain over its long term durability in controlling reflux. The aim of this study was to assess outcome of symptoms for all patients presenting with GORD undergoing routine laparoscopic subtotal Lind fundoplication. All patients undergoing laparoscopic fundoplication between August, 1999 and November, 2007 performed by a single surgeon were included in the study. The anti-reflux procedure studied was laparoscopic Lind (300°) fundoplication with crural repair in all cases. Patients completed pre and post-operative questionnaires containing validated scoring systems for heartburn, gas bloat, dysphagia and overall patient satisfaction. Over the 100-month period, 320 consecutive patients underwent laparoscopic subtotal Lind fundoplication. Of these, 256 (80%) replied to the questionnaire at a mean of 31 months (range 3-96 months) following surgery. 91.4% of respondents had an improvement in heartburn symptom score with a significant reduction in score from 7.74 preoperatively to 1.25 postoperatively (p<0.001). There was also a significant reduction of mean modified Visick score for reflux control (heartburn and regurgitation) from 3.49 preoperatively to 1.48 after surgery (p<0.001). In total, 22 patients developed recurrent reflux symptoms with half of these reporting their recurrence within two years following surgery. Because of this all were tested with post-operative pH testing, yet only one had a 24-h pH time outside the normal range. Overall patient satisfaction was high with a visual analogue score of 9 and 88% of the patients claimed they would have the operation again. Laparoscopic Lind fundoplication demonstrates excellent reflux control when performed routinely for all patients presenting with GORD. This technique is both durable and efficacious in controlling reflux symptoms. Copyright © 2014 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.
System considerations favoring rotary artificial hearts with blood-immersed bearings.
Jarvik, R K
1995-07-01
Hydrodynamic blood pumps provide such advantages as not requiring an air vent or compliance chamber as well as a great reduction in mechanical complexity with the potential for very long durability. The detailed design of their bearings is emerging as the single most important determinant of long-term success. Three categories of bearings include remote force, such as magnetic suspension; blood-isolated, which require a shaft seal; and blood-immersed using either mechanical or hydrodynamic support. Blood-immersed bearings permit maximum simplification and miniaturization of the entire system, require no flush fluid, and require no electronics as with magnetic suspension. The Jarvik 2000 heart represents an example of their potential. The intraventricular titanium pump (25 mm diameter, 25 cc, 85 g), uses blood flow through the motor air gap with blood-immersed bearings. The longest in vitro bearing durability test is ongoing at 20,000,000,000 revolutions with minimal wear (3 years at 15,000 rpm). In vivo results include 5-month calf survival, no thromboembolism, plasma Hb 2-5 mg%, and power under 10 W.
Rosu, Cornelia; Lin, Haisheng; Jiang, Lu; Breedveld, Victor; Hess, Dennis W
2018-04-15
The economical use of water-repellent coatings on polymeric materials in commercial and industrial applications is limited by their mechanical wear robustness and long-term durability. In this study, we demonstrate that polyethylene terephthalate (PET) fabric modified with inorganic, methyltrimethoxysilane (MTMS)-based coatings shows excellent resistance against various types of wear damage, thereby mimicking superhydrophobic biological materials. These features were facilitated by the rational design of coating processing that also enabled tunable hierarchical surface structure. A series of custom and standard testing protocols revealed that coating-to-substrate adhesion was remarkably high, as was the resistance to various mechanical abradents. The most intriguing characteristic observed during aging and abrasion cycles was the enhancement in non-wettability or 'rejuvenation' reflected by water droplet roll-off behavior, a characteristic of self-cleaning materials. Water-repellent properties of coated polyester were also enhanced by prolonged thermal annealing and were maintained after custom laundry. The developed technology offers opportunities to design low cost, durable and functional textiles for both indoor and outdoor applications. Copyright © 2018 Elsevier Inc. All rights reserved.
Bio-artificial pleura using an autologous dermal fibroblast sheet
NASA Astrophysics Data System (ADS)
Kanzaki, Masato; Takagi, Ryo; Washio, Kaoru; Kokubo, Mami; Yamato, Masayuki
2017-10-01
Air leaks (ALs) are observed after pulmonary resections, and without proper treatment, can produce severe complications. AL prevention is a critical objective for managing patients after pulmonary resection. This study applied autologous dermal fibroblast sheets (DFS) to close ALs. For sealing ALs in a 44-year-old male human patient with multiple bullae, a 5 × 15-mm section of skin was surgically excised. From this skin specimen, primary dermal fibroblasts were isolated and cultured for 4 weeks to produce DFSs that were harvested after a 10-day culture. ALs were completely sealed using surgical placement of these autologous DFSs. DFS were found to be a durable long-term AL sealant, exhibiting requisite flexibility, elasticity, durability, biocompatibility, and usability, resulting reliable AL closure. DFS should prove to be an extremely useful tissue-engineered pleura substitute.
Durability of commercial aircraft and helicopter composite structures
NASA Technical Reports Server (NTRS)
Dexter, H. B.
1982-01-01
The development of advanced composite technology during the past decade is discussed. Both secondary and primary components fabricated with boron, graphite, and Kevlar composites are evaluated. Included are spoilers, rudders, and fairings on commercial transports, boron/epoxy reinforced wing structure on C-130 military transports, and doors, fairings, tail rotors, vertical fins, and horizontal stabilizers on commercial helicopters. The development of composite structures resulted in advances in design and manufacturing technology for secondary and primary composite structures for commercial transports. Design concepts and inspection and maintenance results for the components in service are reported. The flight, outdoor ground, and controlled laboratory environmental effects on composites were also determined. Effects of moisture absorption, ultraviolet radiation, aircraft fuels and fluids, and sustained tensile stress are included. Critical parameters affecting the long term durability of composite materials are identified.
Heat Pump Water Heater Durabliltiy Testing - Phase II
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baxter, VAND.
2004-05-29
Ten heat pump water heaters (HPWH) were placed in an environmentally controlled test facility and run through a durability test program of approximately 7300 duty cycles (actual cycles accumulated ranged from 6640 to 8324 for the ten units). Five of the units were upgraded integral types (HPWH mounted on storage tank, no pump) from the same manufacturer as those tested in our first durability program in 2001 (Baxter and Linkous, 2002). The other five were ''add-on'' type units (HPWH with circulation pump plumbed to a separate storage tank) from another manufacturer. This durability test was designed to represent approximately 7-10more » years of normal operation to meet the hot water needs of a residence. The integral units operated without incident apart from two control board failures. Both of these were caused by inadvertent exposure to very hot and humid (>135 F dry bulb and >120 F dew point) conditions that occurred due to a test loop failure. It is not likely that any residential water heater would be installed where such conditions were expected so these failures are not considered a long-term reliability concern. Two of the integral HPWHs featured a condensate management system (CMS) option that effectively eliminated any need for an evaporator condensate drain, but imposed significant efficiency penalties when operating in high humidity ambient conditions. The add-on units experienced no operational failures (breakdowns with loss of hot water production) during the course of the testing. However, their control systems exhibited some performance degradation under the high temperature, high humidity test conditions--HPWHs would shut off with tank water temperatures 15-20 F lower than when operating under moderate ambient conditions. One unit developed a refrigerant leak during the test program and lost about 50% of its charge resulting in reduced efficiency. Efficiency measurements on all the integral units and four of the add-on units showed significantly higher efficiencies than conventional electric water heaters (EWH). DOE Simulated Use Tests conducted prior to starting the durability testing resulted in energy factors (EF) of about 2.3 for the integral design and 1.4 for the add-on design compared to the minimum value of 0.86 prescribed for EWHs. Based on the experience from this and the previous durability testing, there is no evidence that strongly suggests that any of the HPWHs suffered significant performance degradation after undergoing over 7000 water heat cycles.« less
Editorial Commentary: The Acellular Osteochondral Allograft, the Emperor Has New Clothes.
Mandelbaum, Bert R; Chahla, Jorge
2017-12-01
For larger lesions (>2.5-cm 2 ), clinical evidence and practice have shown that fresh osteochondral allograft have good durability, with 88% return to sport and greater than 75% 10-year survival rates for treatment of large femoral condyle lesions. That said, the use of fresh osteochondral allografts in clinical practice is limited by the availability of acceptable donor tissues for eligible patients in a timely fashion. Significant diminution of chondrocyte viability and density occurs during the preservation and storage period. All osteochondral allografts are not equal in performance and outcome. Chondrocyte density and viability are critical for successful transplantation and outcome in the short and long term. This commentary highlights the high failure rates of tissue when it is acellular. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Low Earth orbital atomic oxygen and ultraviolet radiation effects on polymers
NASA Technical Reports Server (NTRS)
Dever, Joyce A.
1991-01-01
Because atomic oxygen and solar ultraviolet radiation present in the low earth orbital (LEO) environment can alter the chemistry of polymers resulting in degradation, their effects and mechanisms of degradation must be determined in order to determine the long term durability of polymeric surfaces to be exposed on missions such as Space Station Freedom. The effects of atomic oxygen on polymers which contain protective coatings must also be explored, since unique damage mechanisms can occur in areas where the protective coatings has failed. Mechanisms can be determined by utilizing results from previous LEO missions, by performing ground based LEO simulation tests and analysis, and by carrying out focussed space experiments. A survey is presented of the interactions and possible damage mechanisms for environmental atomic oxygen and UV radiation exposure of polymers commonly used in LEO.
SERT II thrusters - Still ticking after eleven years
NASA Technical Reports Server (NTRS)
Kerslake, W. R.
1981-01-01
The Space Electric Rocket Test II (SERT II) spacecraft was launched in 1970 with a primary objective of demonstrating long-term operation of a space electric thruster system. An overview is presented of all the SERT II testing conducted during the time from 1970 to 1981. Thruster testing and interaction results are considered, taking into account ion beam thrusting, distant neutralization, and the plasma beam thrust. In a discussion of durability testing, attention is given to the main cathodes, the neutralizer cathodes, the main keeper insulator, the H.V. grid insulators, the neutralizer propellant tanks, and the main propellant tanks. The most important result of the study is related to the confidence gained that mercury bombardment ion thruster systems can be built and operated in space on a routine basis with the same lifetime and performance as measured in ground testing.
Highly Dispersed Alloy Catalyst for Durability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vivek S. Murthi; Izzo, Elise; Bi, Wu
2013-01-08
Achieving DOE's stated 5000-hr durability goal for light-duty vehicles by 2015 will require MEAs with characteristics that are beyond the current state of the art. Significant effort was placed on developing advanced durable cathode catalysts to arrive at the best possible electrode for high performance and durability, as well as developing manufacturing processes that yield significant cost benefit. Accordingly, the overall goal of this project was to develop and construct advanced MEAs that will improve performance and durability while reducing the cost of PEMFC stacks. The project, led by UTC Power, focused on developing new catalysts/supports and integrating them withmore » existing materials (membranes and gas diffusion layers (GDLs)) using state-of-the-art fabrication methods capable of meeting the durability requirements essential for automotive applications. Specifically, the project work aimed to lower platinum group metals (PGM) loading while increasing performance and durability. Appropriate catalysts and MEA configuration were down-selected that protects the membrane, and the layers were tailored to optimize the movements of reactants and product water through the cell to maximize performance while maintaining durability.« less
Durability and Strength of Sustainable Self-Consolidating Concrete Containing Fly Ash
NASA Astrophysics Data System (ADS)
Mohamed, O.; Hawat, W. Al
2018-03-01
In this paper, the durability and strength of self-consolidating concrete (SCC) is assessed through development and testing of six binary mixes at fixed water-to-binder (w/b) ratio of 0.36. In each of the six SCC mixes, a different percentage of cement is replaced with fly ash. The development of compressive strength for each of the mixes is assessed by testing samples after 3, 7, and 28 days of curing. Durability of each of the six SCC mixes is assessed by measuring the charge passed in Rapid Chloride Permeability (RCP) test. Charge passed was measured in samples cured for 1, 3, 7, 14, 28, and 40 days of curing. All mixes out-performed the control mix in terms of resistance to chloride penetration. Binary mix in which 20% of cement is replaced with fly ash exhibited 28-day strength slightly surpassing the control mix.
NASA Astrophysics Data System (ADS)
de Riese, Cornelia; de Riese, Werner T. W.
2003-06-01
Objectives: The treatment of female urinary incontinence (UI) is a growing health care concern in our aging society. Publications of recent innovations and modifications are creating expectations. This brief review provides some insight and structure regarding indications and expected outcomes for the different approaches. Materials: Data extraction is part of a Medline data base search, which was performed for "female stress incontinence" from 1960 until 2000. Additional literature search was performed to cover 2001 and 2002. Outcome data were extracted. Results: (1) INJECTION OF BULKING AGENTS (collagen, synthetic agents): The indication for mucosal coaptation was more clearly defined and in the majority of articles limited to ISD. (2) OPEN COLPOSUSPENSION (Burch, MMK): Best long-term results of all operative procedures, to date considered the gold standard. (3) LAPAROSCOPIC COLPOSUSPENSION (different modifications): Long-term success rates appear dependent on operator skills. There are few long-term data. (4) NEEDLE SUSPENSION: (Stamey, Pareyra and modifications): Initial results were equal to Burch with less morbidity, but long-term success rates are worse. (5) SLING PROCEDURES (autologous, synthetic, allogenic graft materials, different modes of support and anchoring, free tapes): The suburethral sling has traditionally been considered a procedure for those in whom suspension had failed and for those with severe ISD. The most current trend shows its use as a primary procedure for SUI. Long-term data beyond 5 years are insufficient. (6) EXTERNAL OCCLUSIVE DEVICES (vaginal sponges and pessaries, urethral insert): Both vaginal and urethral insert devices can be effective in selected patients. (7) IMPLANTABLE ARTEFICIAL URETHRAL SPHINCTERS: Modifications and improvements of the devices resulted in improved clinical results regarding durability and efficacy. CONCLUSION: (1) The Burch colposuspension is still considered the gold standard in the treatment of female genuine SUI. There is a trend for the suburethral sling to be used as the primary procedure for this indication. Early outcome data are encouraging. New concepts such as use of metalic bone anchors and allograft material as well as the Tension free Vaginal Tape are under investigation. (2) Standardization of diagnostic and therapeutic interventions is prerequisite for any meaningful research. Randomized controlled prospective studies are essential to provide objectives regarding risks and benefits of new procedures and materials.
Musicki, Biljana; Champion, Hunter C; Becker, Robyn E; Liu, Tongyun; Kramer, Melissa F; Burnett, Arthur L
2005-07-01
Despite demonstrated clinical efficacy of sildenafil for the temporary treatment of erectile dysfunction, the possibility that sildenafil used long-term durably augments erectile ability remains unclear. We investigated whether continuous long-term administration of sildenafil at clinically relevant levels to aged rats "primes" the penis for improved erectile ability and involves nitric oxide (NO) or RhoA/Rho-kinase signaling pathways. In aged, but not young rats, sildenafil prolonged erection and increased the protein expressions of phosphorylated endothelial NO synthase (eNOS) at serine-1177 and phosphorylated Akt at serine-473 in penes. Only in the young rat penis, protein expressions of phosphodiesterase-5 and phosphomyosin phosphatase target subunit 1, a marker of Rho-kinase activity, were increased by sildenafil. Sildenafil inhibited phosphodiesterase-5 activity in penes of young and aged rats coincident with assayed free plasma levels of the drug equivalent to clinically therapeutic measurements. We conclude that erectile ability can be enhanced under preconditions of erectile impairment by long-term inhibition of phosphodiesterase-5 and that the effect is mediated by Akt-dependent eNOS phosphorylation. The lack of erectile ability enhancement in young rats by long-term phosphodiesterase-5 inhibition may relate to restrained NO signaling by phosphodiesterase-5 up-regulation, lack of incremental Akt and eNOS phosphorylation, and heightened Rho-kinase signaling in the penis.
Lower esophageal sphincter injections for the treatment of gastroesophageal reflux disease.
Watson, Thomas J; Peters, Jeffrey H
2005-08-01
Endoscopic therapies for the control of GERD offer the potential for significant symptomatic improvement while obviating many of the potential drawbacks associated with long-term medical therapy with acid suppressive or neutralizing medications and traditional antireflux surgery. Such endoluminal therapies are intended to be safe with a brief learning curve, easily administered in an outpatient setting without the need for general anesthesia, reproducible, and durable. LES injection therapies share the common theoretic method of action of bulking at the GEJ, leading to loss of sphincter compliance and distensibility. In the case of Enteryx, this sustained effect has been demonstrated to be secondary to chronic inflammation, fibrosis, and encapsulation resulting from a foreign body response to the injectate. Available data suggest that a majority of patients respond to LES injection therapies, as demonstrated by a decreasing usage of PPIs after implantation, the ability of many patients to terminate PPI use completely, and improved GERD-HRQOL scores. Responses seem reasonably durable in follow-up assessment up to 24 months post treatment. Although there may be some placebo effect associated with treatment, patients injected with Enteryx respond better than a control group of sham-treated subjects. Individuals treated with LES injections, however, represent a select subgroup of the overall population of refluxers. Study subjects, by and large, have had uncomplicated GERD with typical reflux symptoms of heartburn or regurgitation that have responded to PPIs. Patients who have severe anatomic derangements, such as esophageal strictures, persistent esophagitis, Barrett's esophagus, or sizeable hiatal hernias, are excluded from clinical trials, as are patients who have severe motility disorders or significant comorbid conditions. Similarly, patients who have responded poorly to PPIs and those who have primarily extraesophageal manifestations of GERD have not been studied. Outcomes to date have been assessed over the short to medium term; long-term outcome studies are lacking. The durability of response, therefore, remains largely unknown, as does the incidence of any long-term complications or side effects. A postmarket study to assess the long-term safety and durability of Enteryx therapy up to 36 months is under way, as required by the FDA, with a target enrollment of 300 patients. Detailed cost analyses have yet to be reported. Such data are important not only for comparing the various endoluminal therapies but also for comparison to standard medical therapy and antireflux surgery. At present, no randomized trials are completed that compare injection therapies to other accepted treatments of GERD. The ability to perform fundoplication safely and effectively after failed LES injection therapy is not well known, in that the number of subsequent surgical cases is small and the results largely anecdotal to date. Likewise, the ability to use LES injection as salvage therapy after failed fundoplication has not been tested. The data regarding endoluminal injection therapies are similar to those after endoscopic plication and radiofrequency application to the LES, in that a definite symptomatic response is observed, but the objective documentation of diminished esophageal acid exposure lags behind. Esophageal acid exposure is normalized in a minority of treated subjects and improved in an additional subgroup, whereas the rate of symptomatic response exceeds these objective improvements. The reasons for this disconnect are the subject of much speculation and controversy. A placebo effect has been discussed, but clearly more factors are at play. Perhaps a study effect also is important, in that patients enrolled in clinical trials for GERD control may be more likely to modify their dietary and lifestyle habits in an effort to bring about symptom relief. Maybe the understanding of the perception of reflux events is lacking, and these endoluminal therapies work mainly by altering the perception of reflux more than the amount of reflux itself. A recent technologic review of injection therapies for GERD concludes that the "data for Enteryx are as compelling as those of any other open-label evaluation of an endoluminal therapy for GERD". There is much to be learned about all endoluminal techniques. For now, LES injections are promising therapies lacking supportive evidence of long-term safety and efficacy. The available data justify their use only in patients who have GERD symptoms responsive to PPIs and who do not have significant comorbidities or complications associated with GERD. Whether or not the role of LES injection techniques will be expanded to include more complicated cases, patients who are partially responsive to PPIs, combination therapy with other endoluminal techniques, or salvage therapy after failed fundoplication awaits further study.
Depth of Processing and Age Differences.
Kheirzadeh, Shiela; Pakzadian, Sarah Sadat
2016-10-01
The present article is aimed to investigate whether there are any differences between youngsters and adults in their working and long-term memory functioning. The theory of Depth of Processing (Craik and Lockhart in J Verbal Learning Verbal Behav 11:671-684, 1972) discusses the varying degrees of strengths of memory traces as the result of differential levels of processing on the retrieved input. Additionally, they claim that there are three levels of visual, auditory and semantic processes applied on the stimuli in the short-term memory leading to discrepancy in the durability of the memory traces and the later ease of recall and retrieval. In the present article, it is tried to demonstrate if there are evidences of more durable memory traces formed after semantic, visual and auditory processions of the incoming language data in two groups of (a) children in their language learning critical age and (b) youngsters who have passed the critical age period. The comparisons of the results made using two-way ANOVAs revealed the superiority of semantic processing for both age groups in recall, retention and consequently recognition of the new English vocabularies by EFL learners.
Ceramic Single Phase High-Level Nuclear Waste Forms: Hollandite, Perovskite, and Pyrochlore
NASA Astrophysics Data System (ADS)
Vetter, M.; Wang, J.
2017-12-01
The lack of viable options for the safe, reliable, and long-term storage of nuclear waste is one of the primary roadblocks of nuclear energy's sustainable future. The method being researched is the incorporation and immobilization of harmful radionuclides (Cs, Sr, Actinides, and Lanthanides) into the structure of glasses and ceramics. Borosilicate glasses are the main waste form that is accepted and used by today's nuclear industry, but they aren't the most efficient in terms of waste loading, and durability is still not fully understood. Synroc-phase ceramics (i.e. hollandite, perovskite, pyrochlore, zirconolite) have many attractive qualities that glass waste forms do not: high waste loading, moderate thermal expansion and conductivity, high chemical durability, and high radiation stability. The only downside to ceramics is that they are more complex to process than glass. New compositions can be discovered by using an Artificial Neural Network (ANN) to have more options to optimize the composition, loading for performance by analyzing the non-linear relationships between ionic radii, electronegativity, channel size, and a mineral's ability to incorporate radionuclides into its structure. Cesium can be incorporated into hollandite's A-site, while pyrochlore and perovskite can incorporate actinides and lanthanides into their A-site. The ANN is used to predict new compositions based on hollandite's channel size, as well as the A-O bond distances of pyrochlore and perovskite, and determine which ions can be incorporated. These new compositions will provide more options for more experiments to potentially improve chemical and thermodynamic properties, as well as increased waste loading capabilities.
2007-03-31
iterating to the end-time step. 1.3 Code Verification 1.3.1 Statement of the Problem A square aluminum alloy plate (thickness = 1.02 mm, width and...plate. The electro-mechanical properties of the piezoelectric materials (APC850) are available from American Piezoceramics, Inc. . The piezoceramic...structural usage and provide an early indication of physical damage. Piezoelectric (PZT) based SHM systems are among the most widely used for active and
DOE Office of Scientific and Technical Information (OSTI.GOV)
Indacochea, J. E.; Gattu, V. K.; Chen, X.
The results of electrochemical corrosion tests and modeling activities performed collaboratively by researchers at the University of Illinois at Chicago and Argonne National Laboratory as part of workpackage NU-13-IL-UIC-0203-02 are summarized herein. The overall objective of the project was to develop and demonstrate testing and modeling approaches that could be used to evaluate the use of composite alloy/ceramic materials as high-level durable waste forms. Several prototypical composite waste form materials were made from stainless steels representing fuel cladding, reagent metals representing metallic fuel waste streams, and reagent oxides representing oxide fuel waste streams to study the microstructures and corrosion behaviorsmore » of the oxide and alloy phases. Microelectrodes fabricated from small specimens of the composite materials were used in a series of electrochemical tests to assess the corrosion behaviors of the constituent phases and phase boundaries in an aggressive acid brine solution at various imposed surface potentials. The microstructures were characterized in detail before and after the electrochemical tests to relate the electrochemical responses to changes in both the electrode surface and the solution composition. The results of microscopic, electrochemical, and solution analyses were used to develop equivalent circuit and physical models representing the measured corrosion behaviors of the different materials pertinent to long-term corrosion behavior. This report provides details regarding (1) the production of the composite materials, (2) the protocol for the electrochemical measurements and interpretations of the responses of multi-phase alloy and oxide composites, (3) relating corrosion behaviors to microstructures of multi-phase alloys based on 316L stainless steel and HT9 (410 stainless steel was used as a substitute) with added Mo, Ni, and/or Mn, and (4) modeling the corrosion behaviors and rates of several alloy/oxide composite materials made with added lanthanide and uranium oxides. These analyses show the corrosion behaviors of the alloy/ceramic composite materials are very similar to the corrosion behaviors of multi-phase alloy waste forms, and that the presence of oxide inclusions does not impact the corrosion behaviors of the alloy phases. Mixing with metallic waste streams is beneficial to lanthanide and uranium oxides in that they react with Zr in the fuel waste to form highly durable zirconates. The measured corrosion behaviors suggest properly formulated composite materials would be suitable waste forms for combined metallic and oxide waste streams generated during electrometallurgical reprocessing of spent nuclear fuel. Electrochemical methods are suitable for evaluating the durability and modeling long-term behavior of composite waste forms: the degradation model developed for metallic waste forms can be applied to the alloy phases formed in the composite and an affinity-based mineral dissolution model can be applied to the ceramic phases.« less
Flat-plate solar array project. Volume 7: Module encapsulation
NASA Astrophysics Data System (ADS)
Cuddihy, E.; Coulbert, C.; Gupta, A.; Liang, R.
1986-10-01
The objective of the Encapsulation Task was to develop, demonstrate, and qualify photovoltaic (PV) module encapsulation systems that would provide 20 year (later decreased to 30 year) life expectancies in terrestrial environments, and which would be compatible with the cost and performance goals of the Flat-Plate Solar Array (FSA) Project. The scope of the Encapsulation Task included the identification, development, and evaluation of material systems and configurations required to support and protect the optically and electrically active solar cell circuit components in the PV module operating environment. Encapsulation material technologies summarized include the development of low cost ultraviolet protection techniques, stable low cost pottants, soiling resistant coatings, electrical isolation criteria, processes for optimum interface bonding, and analytical and experimental tools for evaluating the long term durability and structural adequacy of encapsulated modules. Field testing, accelerated stress testing, and design studies have demonstrated that encapsulation materials, processes, and configurations are available that meet the FSA cost and performance goals.
Flat-plate solar array project. Volume 7: Module encapsulation
NASA Technical Reports Server (NTRS)
Cuddihy, E.; Coulbert, C.; Gupta, A.; Liang, R.
1986-01-01
The objective of the Encapsulation Task was to develop, demonstrate, and qualify photovoltaic (PV) module encapsulation systems that would provide 20 year (later decreased to 30 year) life expectancies in terrestrial environments, and which would be compatible with the cost and performance goals of the Flat-Plate Solar Array (FSA) Project. The scope of the Encapsulation Task included the identification, development, and evaluation of material systems and configurations required to support and protect the optically and electrically active solar cell circuit components in the PV module operating environment. Encapsulation material technologies summarized include the development of low cost ultraviolet protection techniques, stable low cost pottants, soiling resistant coatings, electrical isolation criteria, processes for optimum interface bonding, and analytical and experimental tools for evaluating the long term durability and structural adequacy of encapsulated modules. Field testing, accelerated stress testing, and design studies have demonstrated that encapsulation materials, processes, and configurations are available that meet the FSA cost and performance goals.
NASA Astrophysics Data System (ADS)
Zaccaria, V.; Tucker, D.; Traverso, A.
2016-09-01
Solid oxide fuel cells are characterized by very high efficiency, low emissions level, and large fuel flexibility. Unfortunately, their elevated costs and relatively short lifetimes reduce the economic feasibility of these technologies at the present time. Several mechanisms contribute to degrade fuel cell performance during time, and the study of these degradation modes and potential mitigation actions is critical to ensure the durability of the fuel cell and their long-term stability. In this work, localized degradation of a solid oxide fuel cell is modeled in real-time and its effects on various cell parameters are analyzed. Profile distributions of overpotential, temperature, heat generation, and temperature gradients in the stack are investigated during degradation. Several causes of failure could occur in the fuel cell if no proper control actions are applied. A local analysis of critical parameters conducted shows where the issues are and how they could be mitigated in order to extend the life of the cell.
Advanced Thermal Barrier and Environmental Barrier Coating Development at NASA GRC
NASA Technical Reports Server (NTRS)
Zhu, Dongming; Robinson, Craig
2017-01-01
This presentation summarizes NASA's advanced thermal barrier and environmental barrier coating systems, and the coating performance improvements that has recently been achieved and documented in laboratory simulated rig test conditions. One of the emphases has been placed on the toughness and impact resistance enhancements of the low conductivity, defect cluster thermal barrier coating systems. The advances in the next generation environmental barrier coatings for SiCSiC ceramic matrix composites have also been highlighted, particularly in the design of a new series of oxide-silicate composition systems to be integrated with next generation SiC-SiC turbine engine components for 2700F coating applications. Major technical barriers in developing the thermal and environmental barrier coating systems are also described. The performance and model validations in the rig simulated turbine combustion, heat flux, steam and calcium-magnesium-aluminosilicate (CMAS) environments have helped the current progress in improved temperature capability, environmental stability, and long-term fatigue-environment system durability of the advanced thermal and environmental barrier coating systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Naus, Dan J; Corum, James; Klett, Lynn B
2006-04-01
This report provides recommended durability-based design properties and criteria for a quais-isotropic carbon-fiber thermoplastic composite for possible automotive structural applications. The composite consisted of a PolyPhenylene Sulfide (PPS) thermoplastic matrix (Fortron's PPS - Ticona 0214B1 powder) reinforced with 16 plies of carbon-fiber unidirectional tape, [0?/90?/+45?/-45?]2S. The carbon fiber was Hexcel AS-4C and was present in a fiber volume of 53% (60%, by weight). The overall goal of the project, which is sponsored by the U.S. Department of Energy's Office of Freedom Car and Vehicle Technologies and is closely coordinated with the Advanced Composites Consortium, is to develop durability-driven design datamore » and criteria to assure the long-term integrity of carbon-fiber-based composite systems for automotive structural applications. This document is in two parts. Part 1 provides design data and correlations, while Part 2 provides the underlying experimental data and models. The durability issues addressed include the effects of short-time, cyclic, and sustained loadings; temperature; fluid environments; and low-energy impacts (e.g., tool drops and kickups of roadway debris) on deformation, strength, and stiffness. Guidance for design analysis, time-independent and time-dependent allowable stresses, rules for cyclic loadings, and damage-tolerance design guidance are provided.« less
M3FT-17OR0301070211 - Preparation of Hot Isostatically Pressed AgZ Waste Form Samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jubin, Robert Thomas; Bruffey, Stephanie H.; Jordan, Jacob A.
The production of radioactive iodine-bearing waste forms that exhibit long-term stability and are suitable for permanent geologic disposal has been the subject of substantial research interest. One potential method of iodine waste form production is hot isostatic pressing (HIP). Recent studies at Oak Ridge National Laboratory (ORNL) have investigated the conversion of iodine-loaded silver mordenite (I-AgZ) directly to a waste form by HIP. ORNL has performed HIP with a variety of sample compositions and pressing conditions. The base mineral has varied among AgZ (in pure and engineered forms), silver-exchanged faujasite, and silverexchanged zeolite A. Two iodine loading methods, occlusion andmore » chemisorption, have been explored. Additionally, the effects of variations in temperature and pressure of the process have been examined, with temperature ranges of 525°C–1,100°C and pressure ranges of 100–300 MPa. All of these samples remain available to collaborators upon request. The sample preparation detailed in this document is an extension of that work. In addition to previously prepared samples, this report documents the preparation of additional samples to support stability testing. These samples include chemisorbed I-AgZ and pure AgI. Following sample preparation, each sample was processed by HIP by American Isostatic Presses Inc. and returned to ORNL for storage. ORNL will store the samples until they are requested by collaborators for durability testing. The sample set reported here will support waste form durability testing across the national laboratories and will provide insight into the effects of varied iodine content on iodine retention by the produced waste form and on potential improvements in waste form durability provided by the zeolite matrix.« less
High performance felt-metal-wick heat pipe for solar receivers
NASA Astrophysics Data System (ADS)
Andraka, Charles E.; Moss, Timothy A.; Baturkin, Volodymyr; Zaripov, Vladlen; Nishchyk, Oleksandr
2016-05-01
Sodium heat pipes have been identified as a potentially effective heat transport approach for CSP systems that require near-isothermal input to power cycles or storage, such as dish Stirling and highly recuperated reheat-cycle supercritical CO2 turbines. Heat pipes offer high heat flux capabilities, leading to small receivers, as well as low exergetic losses through isothermal coupling with the engine. Sandia developed a felt metal wick approach in the 1990's, and demonstrated very high performance1. However, multiple durability issues arose, primarily the structural collapse of the wick at temperature over short time periods. NTUU developed several methods of improving robustness of the wick2, but the resulting wick had limited performance capabilities. For application to CSP systems, the wick structures must retain high heat pipe performance with robustness for long term operation. In this paper we present our findings in developing an optimal balance between performance and ruggedness, including operation of a laboratory-scale heat pipe for over 5500 hours so far. Application of heat pipes to dish-Stirling systems has been shown to increase performance as much as 20%3, and application to supercritical CO2 systems has been proposed.
Low cost space power generation
NASA Technical Reports Server (NTRS)
Olsen, Randall B.
1991-01-01
The success of this study has given a method of fabricating durable copolymer films without size limitations. Previously, only compression molded samples were durable enough to generate electrical energy. The strengthened specimens are very long lived materials. The lifetime was enhanced at least a factor of 1,300 in full pyroelectric conversion cycle experiments compared with extruded, non-strengthened film. The new techniques proved so successful that the lifetime of the resultant copolymer samples was not fully characterized. The lifetime of these new materials is so long that accelerated tests were devised to probe their durability. After a total of more than 67 million high voltage electrical cycles at 100 C, the electrical properties of a copolymer sample remained stable. The test was terminated without any detectable degradation to allow for other experiments. One must be cautious in extrapolating to power cycle performance, but 67 million electrical cycles correspond to 2 years of pyroelectric cycling at 1 Hz. In another series of experiments at reduced temperature and electrical stress, a specimen survived over one-third of a billion electrical cycles during nearly three months of continuous testing. The radiation-limited lifetimes of the copolymer were shown to range from several years to millions of years for most earth orbits. Thus, the pyroelectric copolymer has become a strong candidate for serious consideration for future spacecraft power supplies.
Mechanisms of iodine release from iodoapatite in aqueous solution
NASA Astrophysics Data System (ADS)
Zhang, Z.; Wang, J.
2017-12-01
Immobilization of iodine-129 with waste forms in geological setting is challenging due to its extremely long half-life and high volatility in the environment. To evaluate the long-term performance of waste form, it is imperative to determine the release mechanism of iodine hosted in the waste form materials. This study investigated the iodine released from apatite structured waste form Pb9.85 (VO4)6 I1.7 to understand how diffusion and dissolution control the durability of apatite waste form. A standard semi-dynamic leach test was adopted in this study. Samples were exposed in fresh leachant periodically and the leachant was replaced after each interval. Each experiment was carried out in cap-sealed Teflon vessels under constant temperature (e.g. 90 °C). ICP-MS analysis on the reacted leachates shows that Pb and V were released constantly and congruently with the stoichiometric ratio of Pb/V. However, iodine release is incongruent and time dependent. The iodine release rate starts significantly higher than the corresponding stoichiometric value and gradually decreases, approaching the stoichiometric value. Therefore, a dual-mode mechanism is proposed to account for the iodine release from apatite, which is dominated by short-term diffusion and long-term dissolution processes. Additional tests show that the element release rates depend on a number of test parameters, including sample surface to solution volume ratio (m-1), interval (day), temperature (°C), and solution pH. This study provides a quantitative characterization of iodine release mechanism. The activation energy of iodine leaching 21±1.6 kJ/mol was obtained by varying the test temperature. At the test conditions of to neutral pH and 90 °C, the long-term iodine release rate 3.3 mg/(m2 • day) is projected by normalizing sample surface area to solution volume ratio (S/V) to 1.0 m-1 and interval to 1 day. These findings demonstrate i) the feasibility of our approach to quantify the release mechanism and ii) the performance of iodine apatite as a favorable waste form candidate for I-129 disposal.
NASA Astrophysics Data System (ADS)
Kazaroff, John M.
1993-02-01
Lewis Research Center is developing broad-based new technologies for space chemical engines to satisfy long-term needs of ETO launch vehicles and other vehicles operating in and beyond Earth orbit. Specific objectives are focused on high performance LO2/LH2 engines providing moderate thrusts of 7,5-200 klb. This effort encompasses research related to design analysis and manufacturing processes needed to apply advanced materials to subcomponents, components, and subsystems of space-based systems and related ground-support equipment. High-performance space-based chemical engines face a number of technical challenges. Liquid hydrogen turbopump impellers are often so large that they cannot be machined from a single piece, yet high stress at the vane/shroud interface makes bonding extremely difficult. Tolerances on fillets are critical on large impellers. Advanced materials and fabricating techniques are needed to address these and other issues of interest. Turbopump bearings are needed which can provide reliable, long life operation at high speed and high load with low friction losses. Hydrostatic bearings provide good performance, but transients during pump starts and stops may be an issue because no pressurized fluid is available unless a separate bearing pressurization system is included. Durable materials and/or coatings are needed that can demonstrate low wear in the harsh LO2/LH2 environment. Advanced materials are also needed to improve the lifetime, reliability and performance of other propulsion system elements such as seals and chambers.
Dreger, Peter; Döhner, Hartmut; Ritgen, Matthias; Böttcher, Sebastian; Busch, Raymonde; Dietrich, Sascha; Bunjes, Donald; Cohen, Sandra; Schubert, Jörg; Hegenbart, Ute; Beelen, Dietrich; Zeis, Matthias; Stadler, Michael; Hasenkamp, Justin; Uharek, Lutz; Scheid, Christof; Humpe, Andreas; Zenz, Thorsten; Winkler, Dirk; Hallek, Michael; Kneba, Michael; Schmitz, Norbert; Stilgenbauer, Stephan
2010-10-07
The purpose of this prospective multicenter phase 2 trial was to investigate the long-term outcome of reduced-intensity conditioning allogeneic stem cell transplantation (alloSCT) in patients with poor-risk chronic lymphocytic leukemia. Conditioning was fludarabine/ cyclophosphamide-based. Longitudinal quantitative monitoring of minimal residual disease (MRD) was performed centrally by MRD-flow or real-time quantitative polymerase chain reaction. One hundred eligible patients were enrolled, and 90 patients proceeded to alloSCT. With a median follow-up of 46 months (7-102 months), 4-year nonrelapse mortality, event-free survival (EFS) and overall survival (OS) were 23%, 42%, and 65%, respectively. Of 52 patients with MRD monitoring available, 27 (52%) were alive and MRD negative at 12 months after transplant. Four-year EFS of this subset was 89% with all event-free patients except for 2 being MRD negative at the most recent assessment. EFS was similar for all genetic subsets, including 17p deletion (17p-). In multivariate analyses, uncontrolled disease at alloSCT and in vivo T-cell depletion with alemtuzumab, but not 17p-, previous purine analogue refractoriness, or donor source (human leukocyte antigen-identical siblings or unrelated donors) had an adverse impact on EFS and OS. In conclusion, alloSCT for poor-risk chronic lymphocytic leukemia can result in long-term MRD-negative survival in up to one-half of the patients independent of the underlying genomic risk profile. This trial is registered at http://clinicaltrials.gov as NCT00281983.
Improving patency of coronary conduits "valveless" veins and/or arterial grafts.
Lajos, Thomas Z; Robicsek, Francis; Thubrikar, Mano; Urschel, Harold
2007-01-01
Veins used for coronary artery bypass operation have a well-documented limited long-term patency. Internal thoracic artery (ITA) grafts have shown exceptional "durability." Assumptions were made that other arterial conduits have similar characteristics. The purpose of this article is to compare different conduits long-term patency including saphenous veins to other available arterial conduits: inferior epigastric artery (IE), right gastroepiploic artery (RGEA), and radial artery (RA). Recent studies have shown that radial artery bypasses have lower patency rate than saphenous veins. Flow patterns, physiological flow characteristics are reviewed including native vessel disease and area of myocardium supplied. In the case of venous bypasses, the primary culprit of failure seemed to be the quality of the vein itself and the reverse venous valves in the conduit resulting in: (a) trapping-hypertension, (b) thrombosis, (c) turbulence, (d) intimal damage, (e) mismatching in size. Clinical follow-up of our patients up to 8 to 11 years (average 8.9 years) have proved the superior characteristics of the so-called "good veins." In a retrospective study of 436 patients sequential, valveless veins patency was 88.6% versus 72% of reversed valvular segments (p < 0.01). Patients' survival seemed to be significantly improved if these veins were combined with ITA grafts. Patients' survival with one valveless limb HS + ITA was 78% versus HS + SV 52% (p < or = 0.0017) and HS + ITA versus HS + ITA + SV (p < 0.0057). Selective decision-making of the surgeon at the time of the operation is required to choose the best conduit to be able to perform the best operation with the best long-term result.
Urethral reconstruction in patients suffering from aphallia: a reconstructive challenge.
Bhandari, Mahendra; Sinha, Rahul Janak; Singh, Vishwajeet
2011-01-01
To document our experience (at a tertiary health care center) of reconstruction of the urethra in 3 male patients suffering from aphallia and congenital urethrorectal fistula as well as their long-term follow-up. Extensive single-stage urethroplasty in 3 patients suffering from aphallia was performed. Prior to that, neophallus reconstruction was done in all 3 patients after puberty. In a single stage, we used oral mucosa and pedicled penile skin onlay for anterior urethra reconstruction and groin-based pedicle (Singapore) flap for posterior urethra substitution surgery. The current follow-up is between 2 and 5 years. During the last follow-up, the patients also answered questions from a validated patient-reported outcome measure and quality of life questionnaire. All the 3 patients are voiding well in the standing position with a mean Q(max) of 14 ml/s. None of them has any problems related to the neourethra as per their last follow-up. All 3 patients were satisfied with the surgical procedures related to the aphallia correction and stated that the surgery did not interfere with the quality of their lives. Reconstruction of the urethra from pedicled skin flap combined with buccal mucosa graft urethroplasty gives durable and satisfactory long-term results. Copyright © 2011 S. Karger AG, Basel.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-18
... Production Act of 1993--Cooperative Research Group on Particle Sensor Performance and Durability Notice is... Research Group on Particle Sensor Performance and Durability (``PSPD'') has filed written notifications... the performance and durability of various particle sensor technologies on a diesel engine platform...
Nuclear waste forms for actinides
Ewing, Rodney C.
1999-01-01
The disposition of actinides, most recently 239Pu from dismantled nuclear weapons, requires effective containment of waste generated by the nuclear fuel cycle. Because actinides (e.g., 239Pu and 237Np) are long-lived, they have a major impact on risk assessments of geologic repositories. Thus, demonstrable, long-term chemical and mechanical durability are essential properties of waste forms for the immobilization of actinides. Mineralogic and geologic studies provide excellent candidate phases for immobilization and a unique database that cannot be duplicated by a purely materials science approach. The “mineralogic approach” is illustrated by a discussion of zircon as a phase for the immobilization of excess weapons plutonium. PMID:10097054
NASA Technical Reports Server (NTRS)
Podojil, Gregg M.; Jaworske, Donald A.
1993-01-01
Atomic oxygen degradation is one of several major threats to the durability of spaceborne systems in low Earth orbit. Ground-based simulations are conducted to learn how to minimize the adverse effects of atomic oxygen exposure. Assessing the fluence of atomic oxygen in test chambers such as a plasma asher over long periods of time is necessary for accurate determination of atomic oxygen exposure. Currently, an atomic oxygen susceptible organic material such as Kapton is placed next to samples as a witness coupon and its mass loss is monitored and used to determine the effective atomic oxygen fluence. However, degradation of the Kapton witness coupons occurs so rapidly in plasma ashers that for any long term test many witness coupons must be used sequentially in order to keep track of the fluence. This necessitates opening vacuum to substitute fresh coupons. A passive dosimetry technique was sought to monitor atomic oxygen exposure over longer periods without the need to open the plasma asher to the atmosphere. This paper investigates the use of spectrophotometric analysis of durable IR transparent witness coupons to measure atomic oxygen exposure for longer duration testing. The method considered would be conductive to making in situ measurements of atomic oxygen fluence.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Southface Energy Institute (Southface) partnered with owners and/or builders with various market constraints and ultimate goals for three projects in different climate zones: Savannah, GA (CZ 2), Clemson, SC (CZ 3), and LaFayette, GA (CZ 4). This report documents the design process, computational energy modeling, construction, envelope performance metrics, long-term monitoring results, and successes and failures of the design and execution of these high performance homes. The three bedroom/two bathroom test home in Savannah Gardens on an elevated slab foundation has a semi-conditioned, encapsulated attic. A neighboring home built to EarthCraft specifications was also monitored as a control for exteriormore » foam insulation and a heat pump water heater (HPWH). For the JMC Patrick Square, a single-story project in Clemson, the small-scale production builder wanted to increase their level of energy efficiency beyond their current green building practices, including bringing ducts into conditioned space. Through a combination of upgrade measures the team met this goal and achieved many Zero Energy Ready Home requirements. LaFayette Housing Authority undertook a development of 30 affordable rental housing units in 15 duplexes in LaFayette, GA. Because they would be long-term owners, their priorities were low utility bills for the residents and durable, maintainable buildings. The team employed BEopt to optimize building envelope and systems choices, including 2x6 advanced framed walls, insulated slab, and heat pump water heater in a utility closet which was ducted to/from an encapsulated attic.« less
Meng, Tian; Kou, Zongkui; Amiinu, Ibrahim Saana; Hong, Xufeng; Li, Qingwei; Tang, Yongfu; Zhao, Yufeng; Liu, Shaojun; Mai, Liqiang; Mu, Shichun
2018-04-17
Tuning the electron structure is of vital importance for designing high active electrode materials. Here, for boosting the capacitive performance of tungsten oxide, an atomic scale engineering approach to optimize the electronic structure of tungsten oxide by Ni doping is reported. Density functional theory calculations disclose that through Ni doping, the density of state at Fermi level for tungsten oxide can be enhanced, thus promoting its electron transfer. When used as electrode of supercapacitors, the obtained Ni-doped tungsten oxide with 4.21 at% Ni exhibits an ultrahigh mass-specific capacitance of 557 F g -1 at the current density of 1 A g -1 and preferable durability in a long-term cycle test. To the best of knowledge, this is the highest supercapacitor performance reported so far in tungsten oxide and its composites. The present strategy demonstrates the validity of the electronic structure control in tungsten oxide via introducing Ni atoms for pseudocapacitors, which can be extended to other related fields as well. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ten-kilogram vehicle autonomous operations
NASA Astrophysics Data System (ADS)
Rogers, John R.; Korpela, Christopher; Quigley, Kevin
2009-05-01
A low-cost unmanned ground vehicle designed to benchmark high-speed performance is presented. The E-Maxx four-wheel-drive radio-controlled vehicle equipped with a Robostix controller is proposed as a low-cost, high-speed robotic platform useful for military operations. The vehicle weighs less than ten kilograms making it easily portable by one person. Keeping cost low is a major consideration in the design with the aim of providing a disposable military robot. The suitability of the platform was evaluated and results are presented. Commercial-Off-The-Shelf (COTS) upgrades to the basic vehicle are recommended for durability. A procedure was established for bird's-eye-view video recording to document vehicle dynamics. Driver/vehicle performance is quantified by entry velocity, exit velocity and total time through a 90° turn on low-friction terrain. A setup for measuring these values is presented. Expert drivers use controlled skidding to minimize time through turns and the long term goal of the project is to automate such expert behaviors. Results of vehicle performance under human control are presented and stand as a reference for future autonomy.
Specifying, Installing and Maintaining Built-Up and Modified Bitumen Roofing Systems.
ERIC Educational Resources Information Center
Hobson, Joseph W.
2000-01-01
Examines built-up, modified bitumen, and hybrid combinations of the two roofing systems and offers advise on how to assure high- quality performance and durability when using them. Included is a glossary of commercial roofing terms and asphalt roofing resources to aid in making decisions on roofing and systems product selection. (GR)
Raffo, Simona; Vassura, Ivano; Chiavari, Cristina; Martini, Carla; Bignozzi, Maria C; Passarini, Fabrizio; Bernardi, Elena
2016-06-01
Surface and building runoff can significantly contribute to the total metal loading in urban runoff waters, with potential adverse effects on the receiving ecosystems. The present paper analyses the corrosion-induced metal dissolution (Fe, Mn, Cr, Ni, Cu) from weathering steel (Cor-Ten A) with or without artificial patinas, exposed for 3 years in unsheltered conditions at a marine urban site (Rimini, Italy). The influence of environmental parameters, atmospheric pollutants and surface finish on the release of dissolved metals in rain was evaluated, also by means of multivariate analysis (two-way and three-way Principal Component Analysis). In addition, surface and cross-section investigations were performed so as to monitor the patina evolution. The contribution provided by weathering steel runoff to the dissolved Fe, Mn and Ni loading at local level is not negligible and pre-patination treatments seem to worsen the performance of weathering steel in term of metal release. Metal dissolution is strongly affected by extreme events and shows seasonal variations, with different influence of seasonal parameters on the behaviour of bare or artificially patinated steel, suggesting that climate changes could significantly influence metal release from this alloy. Therefore, it is essential to perform a long-term monitoring of the performance, the durability and the environmental impact of weathering steel. Copyright © 2016 Elsevier Ltd. All rights reserved.
Jessop, Zita M; Javed, Muhammad; Otto, Iris A; Combellack, Emman J; Morgan, Siân; Breugem, Corstiaan C; Archer, Charles W; Khan, Ilyas M; Lineaweaver, William C; Kon, Moshe; Malda, Jos; Whitaker, Iain S
2016-01-28
Recent advances in regenerative medicine place us in a unique position to improve the quality of engineered tissue. We use auricular cartilage as an exemplar to illustrate how the use of tissue-specific adult stem cells, assembly through additive manufacturing and improved understanding of postnatal tissue maturation will allow us to more accurately replicate native tissue anisotropy. This review highlights the limitations of autologous auricular reconstruction, including donor site morbidity, technical considerations and long-term complications. Current tissue-engineered auricular constructs implanted into immune-competent animal models have been observed to undergo inflammation, fibrosis, foreign body reaction, calcification and degradation. Combining biomimetic regenerative medicine strategies will allow us to improve tissue-engineered auricular cartilage with respect to biochemical composition and functionality, as well as microstructural organization and overall shape. Creating functional and durable tissue has the potential to shift the paradigm in reconstructive surgery by obviating the need for donor sites.
Song, Ha-Won; Saraswathy, Velu
2006-11-16
The partial replacement of clinker, the main constituent of ordinary Portland cement by pozzolanic or latent hydraulic industrial by-products such as ground granulated blast furnace slag (GGBFS), effectively lowers the cost of cement by saving energy in the production process. It also reduces CO2 emissions from the cement plant and offers a low priced solution to the environmental problem of depositing industrial wastes. The utilization of GGBFS as partial replacement of Portland cement takes advantage of economic, technical and environmental benefits of this material. Recently offshore, coastal and marine concrete structures were constructed using GGBFS concrete because high volume of GGBFS can contribute to the reduction of chloride ingress. In this paper, the influence of using GGBFS in reinforced concrete structures from the durability aspects such as chloride ingress and corrosion resistance, long term durability, microstructure and porosity of GGBFS concrete has been reviewed and discussed.
New immiscible refrigeration lubricant for HFCs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sunami, Motoshi; Takigawa, Katsuya; Suda, Satoshi
1995-12-31
This study examines the capability of a family of very low-viscosity alkylbenzenes (AB) used in high-side rotary compressors for HFCs. In the development of refrigeration lubricants for HFCs, miscibility is one of the most important problems to be solved. Therefore, PAG (polyalkylene glycols) and POE (polyol esters), which have good miscibility, have been applied in new HFC applications. However, it is difficult for these lubricants to maintain long-term durability in high-side rotary compressors. In friction tests under high HFC pressure, ABs with much lower viscosities than mineral oil maintained a much stronger oil film than the combination of mineral oil/R-12more » or POE/HFCs. These results were also proven by compressor durability tests. From the study of the solubility of ABs and HFCs, it is suggested that the total amount of refrigerant can be reduced because HFCs are barely soluble with ABs inside the high-side shell.« less
Vegter, S; Tolley, K; Wilson Waterworth, T; Jones, H; Jones, S; Jewell, D
2013-08-01
The antisense ICAM-1 inhibitor alicaforsen has been studied in four phase 2 studies in ulcerative colitis (UC). Recruited patients varied as to the extent of their colitis and in the severity of disease at entry. To investigate the efficacy of alicaforsen enema in specific UC populations. Efficacy was analysed for short-term (week 6-10) and long-term (week 30) outcomes compared with either placebo or a high-dose mesalazine (mesalamine) enema in patients with disease extent up to 40 cm from the anal verge in patients with moderate or severe disease, and in patients with both of these features. Individual patient data meta-analyses of 200 patients from four phase 2 studies evaluating nightly alicaforsen 240 mg enema and comparators. Patient data were pooled and analysed in a single data set. Continuous outcomes were evaluated using anova; dichotomous outcomes were evaluated using Pearson chi-square or Fisher's exact tests. Alicaforsen showed superior efficacy vs. placebo in: patients with disease extent up to 40 cm, patients with moderate and severe disease and especially when both those conditions were satisfied. In these patient groups, mesalazine also showed short-term efficacy. At week 30, however, the efficacy of mesalazine waned and alicaforsen became significantly more efficacious. This post hoc meta-analysis showed that alicaforsen is effective in patients with active UC, especially in patients with distal disease, which is of moderate/severe activity. The efficacy of alicaforsen was durable in these sub-groups, suggesting a disease-modifying effect. This analysis suggests that alicaforsen enema may offer an effective, potentially durable response in moderate/severe distal active UC. © 2013 John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pierce, Eric M.; Bacon, Diana H.
2009-09-21
The interest in the long-term durability of waste glass stems from the need to predict radionuclide release rates from the corroding glass over geologic time-scales. Several long-term test methods have been developed to accelerate the glass-water reaction [drip test, vapor hydration test, product consistency test-B, and pressurized unsaturated flow (PUF)]. Currently, the PUF test is the only method that can mimic the unsaturated hydraulic properties expected in a subsurface disposal facility and simultaneously monitor the glass-water reaction. PUF tests are being conducted to accelerate the weathering of glass and validate the model parameters being used to predict long-term glass behavior.more » One dimensional reactive chemical transport simulations of glass dissolution and secondary phase formation during a 1.5-year long PUF experiment was conducted with the subsurface transport over reactive multi-phases (STORM) code. Results show that parameterization of the computer model by combining direct laboratory measurements and thermodynamic data provides an integrated approach to predicting glass behavior over geologic-time scales.« less
Strong, Amy L; Bennett, Danielle K; Spreen, Elizabeth B; Adhvaryu, Dhaval V; Littleton, Jeffrey C; Mencer, Ernest J
2016-01-01
The treatment of full thickness skin wounds commonly associated with large burns continues to represent a challenging clinical entity. The current treatment for large TBSA burns is split thickness autologous skin grafting; however, this treatment often results in poor textural durability, hypertrophic scarring, and fibrotic contractures. In this case report, we describe our experience and long-term follow-up results after the application of fetal bovine collagen (FBC) matrix (PriMatrix, TEI Biosciences, Boston, MA) to burn wounds clinically assessed as full thickness that healed without the need for subsequent skin grafting. The patient presented with 25% TBSA burns and was debrided and covered with FBC on postburn day 7. By postoperative day 12, the patient had large areas of reepithelialization distributed throughout the wound bed. By postoperative day 26, the patient had significantly more areas of wound closure and was discharged. Reepithelialization and repigmentation continued, and long-term follow-up after 26 months demonstrated complete reepithelialization and nearly complete repigmentation, without the appearance of contractures or hypertrophic scarring. This case report highlights the use of FBC as a scaffold capable of dermal regeneration and spontaneous reepithelialization with an excellent long-term functional and cosmetic outcome.
Strong, Amy L.; Bennett, Danielle K.; Spreen, Elizabeth B.; Adhvaryu, Dhaval V.; Littleton, Jeffrey C.
2016-01-01
The treatment of full thickness skin wounds commonly associated with large burns continues to represent a challenging clinical entity. The current treatment for large TBSA burns is split thickness autologous skin grafting; however, this treatment often results in poor textural durability, hypertrophic scarring, and fibrotic contractures. In this case report, we describe our experience and long-term follow-up results after the application of fetal bovine collagen (FBC) matrix (PriMatrix, TEI Biosciences, Boston, MA) to burn wounds clinically assessed as full thickness that healed without the need for subsequent skin grafting. The patient presented with 25% TBSA burns and was debrided and covered with FBC on postburn day 7. By postoperative day 12, the patient had large areas of reepithelialization distributed throughout the wound bed. By postoperative day 26, the patient had significantly more areas of wound closure and was discharged. Reepithelialization and repigmentation continued, and long-term follow-up after 26 months demonstrated complete reepithelialization and nearly complete repigmentation, without the appearance of contractures or hypertrophic scarring. This case report highlights the use of FBC as a scaffold capable of dermal regeneration and spontaneous reepithelialization with an excellent long-term functional and cosmetic outcome. PMID:25494213
Volatile Reaction Products From Silicon-Based Ceramics in Combustion Environments Identified
NASA Technical Reports Server (NTRS)
Opila, Elizabeth J.
1997-01-01
Silicon-based ceramics and composites are prime candidates for use as components in the hot sections of advanced aircraft engines. These materials must have long-term durability in the combustion environment. Because water vapor is always present as a major product of combustion in the engine environment, its effect on the durability of silicon-based ceramics must be understood. In combustion environments, silicon-based ceramics react with water vapor to form a surface silica (SiO2) scale. This SiO2 scale, in turn, has been found to react with water vapor to form volatile hydroxides. Studies to date have focused on how water vapor reacts with high-purity silicon carbide (SiC) and SiO2 in model combustion environments. Because the combustion environment in advanced aircraft engines is expected to contain about 10-percent water vapor at 10-atm total pressure, the durability of SiC and SiO2 in gas mixtures containing 0.1- to 1-atm water vapor is of interest. The reactions of SiC and SiO2 with water vapor were monitored by measuring weight changes of sample coupons in a 0.5-atm water vapor/0.5-atm oxygen gas mixture with thermogravimetric analysis.
Polyimide Film of Increased Tear Strength
NASA Technical Reports Server (NTRS)
St. Clair, A. K.; Hinkley, J. A.; Ezzell, S. A.
1986-01-01
High-temperature linear aromatic polyimide with improved resistance to tearing made by new process that incorporates elastomer into polyimide. Linear aromatic condensation polyimides are materials of prime choice for use as films and coatings on advanced spacecraft and aircraft where durability at temperatures in range of 200 to 300 degree C required. Elastomer-containing polyimide film with improved toughness proves useful for applications where resistance to tearing and long-term thermal stability necessary. Desired resistance to tearing achieved by careful control of amount and chemical composition of added elastomer.
NASA Technical Reports Server (NTRS)
Aniversario, R. B.; Harvey, S. T.; Mccarty, J. E.; Parsons, J. T.; Peterson, D. C.; Pritchett, L. D.; Wilson, D. R.; Wogulis, E. R.
1982-01-01
Results of tests conducted to demonstrate that composite structures save weight, possess long term durability, and can be fabricated at costs competitive with conventional metal structures are presented with focus on the use of graphite-epoxy in the design of a stabilizer for the Boeing 737 aircraft. Component definition, materials evaluation, material design properties, and structural elements tests are discussed. Fabrication development, as well as structural repair and inspection are also examined.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hacke, P.
2012-03-01
Over the past decade, there have been observations of module degradation and power loss because of the stress that system voltage bias exerts. This results in part from qualification tests and standards note adequately evaluating for the durability of modules to the long-term effects of high voltage bias that they experience in fielded arrays. This talk deals with factors for consideration, progress, and information still needed for a standardized test for degradation due to system voltage stress.
van de Weijer, M A J; Vonken, E J P A; de Vries, J-P P M; Moll, F L; Vos, J A; de Borst, G J
2015-07-01
Endovascular treatment of atherosclerotic obstruction of aortic arch branch origins (AABO) has largely replaced open surgery, but long-term outcome data are lacking. This study evaluated mid-term and long-term results of these procedures. Retrospective cohort study. Patients underwent endovascular treatment for symptomatic atherosclerotic stenosis of AABO between 1995 and 2012. Technical success was defined as uncomplicated revascularization and residual stenosis ≤30%. The primary end point was freedom from restenosis ≥50% on Duplex ultrasonography or magnetic resonance angiography. Secondary end points were freedom from target lesion revascularization or recurrent symptoms. 144 lesions were treated in 114 patients (75 female; mean age 66.3 years), by percutaneous transluminal angioplasty (PTA) in 20 patients and PTA and stent in 117 patients (brachiocephalic artery [BCA] 9/54; left common carotid artery [LCCA] 0/7; left subclavian artery [LSA] 11/56). The lesion could not be passed in four patients, and in three patients the intervention was terminated before angioplasty. The 30-day technical success was 94.4%, without deaths or strokes. Mean follow-up was 52.0 months (range 2-163 months). Restenosis-free survival was 95.6%, 92.9%, 87.6%, and 83.2% at 12, 24, 48, and 60 months, respectively. Log-rank test showed no significant difference between PTA only and PTA with additional stent placement at any point (p = .375), nor between BCA (n = 51), LCCA (n = 6), or LSA (n = 57). During follow-up, 27 patients (23.7%) became symptomatic (15 BCA, 1 LCCA, and 11 LSA); 19 patients with a restenosis of the target lesion (mean 56.7 months). Symptom-free survival was 94.7%, 92.0%, 82.3%, and 77.9% at 12, 24, 48, and 60 months, respectively. Endovascular treatment of aortic arch branch origin obstruction is safe and efficacious in experienced hands and can be considered as the preferred treatment, with good mid-term durability. Recurrent symptomatic lesions can be treated safely by renewed endovascular means. Copyright © 2015 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Wu, Yongzhen; Zhu, Wei-Hong; Zakeeruddin, Shaik M; Grätzel, Michael
2015-05-13
The dye-sensitized solar cell (DSSC) is one of the most promising photovoltaic technologies with potential of low cost, light weight, and good flexibility. The practical application of DSSCs requires further improvement in power conversion efficiency and long-term stability. Recently, significant progress has been witnessed in DSSC research owing to the novel concept of the D-A-π-A motif for the molecular engineering of organic photosensitizers. New organic and porphyrin dyes based on the D-A-π-A motif can not only enhance photovoltaic performance, but also improve durability in DSSC applications. This Spotlight on Applications highlights recent advances in the D-A-π-A-based photosensitizers, specifically focusing on the mechanism of efficiency and stability enhancements. Also, we find insight into the additional acceptor as well as the trade-off of long wavelength response. The basic principles are involved in molecular engineering of efficient D-A-π-A sensitizers, providing a clear road map showing how to modulate the energy bands, rationally extending the response wavelength, and optimizing photovoltaic efficiency step by step.
Uncemented total hip arthroplasty in chronic hemodialysis patients
Li, Wei-Chun; Shih, Chun-Hsiung; Ueng, Steve W; Shih, Hsin-Nung; Lee, Mel S
2010-01-01
Background and purpose Whether or not uncemented total hip arthroplasty (THA) can achieve durable fixation of implants to bone in patients on chronic hemodialysis is unknown. We analyzed the 2–13-year clinical outcomes of cementless THA in patients with end-stage renal diseases who were maintained on long-term hemodialysis. Patients and methods We reviewed the outcome of 23 consecutive uncemented THAs undertaken between 1993 and 2004, in patients with chronic renal failure who had been on long-term hemodialysis (2–18 years). 1 patient died and 2 patients were lost to follow-up within 2 years, leaving 20 hips (20 patients, median age 66 (38–81) years at the time of THA, 11 females) that were reviewed at median 7 (2–13) years postoperatively. Results Radiographic bone-ingrowth fixation of the components was found in 19 patients. 1 patient had aseptic loosening requiring revision surgery. The median d'Aubigne and Postel score was 10 (8–14) preoperatively and 15 (12–18) at final review. No prosthetic infections were found in any of the patients. Interpretation Uncemented THA shows promising medium-term results in patients receiving long-term hemodialysis. PMID:20175645
Reflector Technology Development and System Design for Concentrating Solar Power Technologies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adam Schaut
2011-12-30
Alcoa began this program in March of 2008 with the goal of developing and validating an advanced CSP trough design to lower the levelized cost of energy (LCOE) as compared to existing glass based, space-frame trough technology. In addition to showing a pathway to a significant LCOE reduction, Alcoa also desired to create US jobs to support the emerging CSP industry. Alcoa's objective during Phase I: Concept Feasibility was to provide the DOE with a design approach that demonstrates significant overall system cost savings without sacrificing performance. Phase I consisted of two major tasks; reflector surface development and system conceptmore » development. Two specific reflective surface technologies were investigated, silver metallized lamination, and thin film deposition both applied on an aluminum substrate. Alcoa prepared samples; performed test validation internally; and provided samples to the NREL for full-spectrum reflectivity measurements. The final objective was to report reflectivity at t = 0 and the latest durability results as of the completion of Phase 1. The target criteria for reflectance and durability were as follows: (1) initial (t = 0), hemispherical reflectance >93%, (2) initial spectral reflectance >90% for 25-mrad reading and >87% for 7-mrad reading, and (3) predicted 20 year durability of less than 5% optical performance drop. While the results of the reflective development activities were promising, Alcoa was unable to down-select on a reflective technology that met the target criteria. Given the progress and potential of both silver film and thin film technologies, Alcoa continued reflector surface development activities in Phase II. The Phase I concept development activities began with acquiring baseline CSP system information from both CSP Services and the DOE. This information was used as the basis to develop conceptual designs through ideation sessions. The concepts were evaluated based on estimated cost and high-level structural performance. The target criteria for the concept development was to achieve a solar field cost savings of 25%-50% thereby meeting or exceeding the DOE solar field cost savings target of $350/m2. After evaluating various structural design approaches, Alcoa down-selected to a monocoque, dubbed Wing Box, design that utilizes the reflective surface as a structural, load carrying member. The cost and performance potential of the Wing Box concept was developed via initial finite element analysis (FEA) and cost modeling. The structural members were sized through material utilization modeling when subjected to representative loading conditions including wind loading. Cost modeling was utilized to refine potential manufacturing techniques that could be employed to manufacture the structural members. Alcoa concluded that an aluminum intensive collector design can achieve significant cost savings without sacrificing performance. Based on the cost saving potential of this Concept Feasibility study, Alcoa recommended further validation of this CSP approach through the execution of Phase II: Design and Prototype Development. Alcoa Phase II objective was to provide the DOE with a validated CSP trough design that demonstrates significant overall system cost savings without sacrificing performance. Phase II consisted of three major tasks; Detail System Design, Prototype Build, and System Validation. Additionally, the reflector surface development that began in Phase I was continued in Phase II. After further development work, Alcoa was unable to develop a reflective technology that demonstrated significant performance or cost benefits compared to commercially available CSP reflective products. After considering other commercially available reflective surfaces, Alcoa selected Alano's MIRO-SUN product for use on the full scale prototype. Although MIRO-SUN has a lower specular reflectivity compared to other options, its durability in terms of handling, cleaning, and long-term reflectivity was deemed the most important attribute to successfully validate Alcoa's advanced trough architecture. To validate the performance of the Wing Box trough, a 6 meter aperture by 14 meter long prototype trough was built. For ease of shipping to and assembly at NREL's test facility, the prototype was fabricated in two half modules and joined along the centerline to create the Wing Box trough. The trough components were designed to achieve high precision of the reflective surface while leveraging high volume manufacturing and assembly techniques.« less
DOT National Transportation Integrated Search
2017-05-01
This report is a summary of the research done on dynamic segregation of self-consolidating concrete (SCC) including the casting of pre-stressed beams at Coreslab Structures. SCC is a highly flowable concrete that spreads into place with little to no ...
Investigation into the effects of sulfur on syngas reforming inside a solid oxide fuel cell
NASA Astrophysics Data System (ADS)
Li, Ting Shuai; Xu, Min; Gao, Chongxin; Wang, Baoqing; Liu, Xiyun; Li, Baihai; Wang, Wei Guo
2014-07-01
The electrochemical performance and long-term durability of a solid oxide fuel cell have been evaluated with a simulated coal syngas containing 2 ppm H2S as fuel. The resulting impedance spectra indicate that no observable power loss is caused by the addition of 2 ppm H2S, and the cell shows stability of nearly 500 h at 0.625 A cm-2. The composition of mixed gas is analyzed both at a current load of 0.625 A cm-2 and open circuit state. Hydrogen and carbon monoxide are directly consumed as fuels at the anode side, whereas methane stays unchanged during the operation. It seems the internal carbohydrate reforming and impurity poisoning interacts and weakens the poisoning effects. The oxidation of H2 and the water gas shift reaction take advantages over methane reforming at the cell operational conditions.
Development of nickel-metal hydride cell: An update
NASA Technical Reports Server (NTRS)
Kuwajima, S.; Kusawake, Hiroaki; Nakatani, Kensuke; Yano, Y.
1994-01-01
This paper presents in viewgraph format an overview of NASDA's evaluation of commercial nickel metal-hydride (Ni-MH) cells and the development and testing of Ni-MH cells for use in space. The commercial cells are concluded to be feasible and suitable for use in LEO; for GEO, the durability for overcharge is needed because long-term charge retention is required. For the aerospace Ni-MH cell design, two activation procedures are applied to evaluate the effect of the difference in the amount of overcharge protection and precharge. Specific energy of the Ni-MH cell is nearly accomplished at 50 Wh/kg. Initial characteristics indicate the effect derived from precharge. Thirty-five amp-hour class Ni-MH cells have good performance for LEO cycle of 25 and 40 percent DOD up to 3000 cycles as similar to commercial cells. The effect of the difference in the amount of overcharge protection will appear in life test.
Supportability evaluation of thermoplastic and thermoset composites
NASA Technical Reports Server (NTRS)
Chanani, G. R.; Boldi, D.; Cramer, S. G.; Heimerdinger, M. W.
1990-01-01
Nearly 300 advanced composite components manufactured by Northrop Corporation are flying on U.S. Air Force and U.S. Navy supersonic aircraft as part of a three-year Air Force/Navy/Northrop supportability evaluation. Both thermoplastic and high-temperature thermoset composites were evaluated for their in-service performance on 48 USAF and Navy F-5E fighter and USAFT-38 trainer aircraft in the first large-scale, long-term maintenance evaluation of these advanced materials. Northrop manufactured four types of doors for the project-avionics bay access, oil fill, inlet duct inspection, and a main landing gear door. The doors are made of PEEK (polyetheretherketone) thermoplastic, which is tougher and potentially less expensive to manufacture than conventional composites; and 5250-3 BMI (bismaleimide) thermoset, which is manufactured like a conventional epoxy composite but can withstand higher service temperatures. Results obtained so far indicate that both the BMI and PEEK are durable with PEEK being somewhat better than BMI.
High-energy redox-flow batteries with hybrid metal foam electrodes.
Park, Min-Sik; Lee, Nam-Jin; Lee, Seung-Wook; Kim, Ki Jae; Oh, Duk-Jin; Kim, Young-Jun
2014-07-09
A nonaqueous redox-flow battery employing [Co(bpy)3](+/2+) and [Fe(bpy)3](2+/3+) redox couples is proposed for use in large-scale energy-storage applications. We successfully demonstrate a redox-flow battery with a practical operating voltage of over 2.1 V and an energy efficiency of 85% through a rational cell design. By utilizing carbon-coated Ni-FeCrAl and Cu metal foam electrodes, the electrochemical reactivity and stability of the nonaqueous redox-flow battery can be considerably enhanced. Our approach intoduces a more efficient conversion of chemical energy into electrical energy and enhances long-term cell durability. The cell exhibits an outstanding cyclic performance of more than 300 cycles without any significant loss of energy efficiency. Considering the increasing demands for efficient energy storage, our achievement provides insight into a possible development pathway for nonaqueous redox-flow batteries with high energy densities.
Li, Ji-Sen; Zhang, Shuai; Sha, Jing-Quan; Wang, Hao; Liu, Ming-Zhu; Kong, Ling-Xin; Liu, Guo-Dong
2018-05-09
Highly efficient electrocatalysts for hydrogen evolution reactions (HER) are crucial for electrochemical water splitting, where high-cost and low-abundance Pt-based materials are the benchmark catalysts for HER. Herein, we report the fabrication of MoP nanoparticles confined in P-doped porous carbon (MoP@PC) via a metal-organic framework-assisted route for the first time. Remarkably, due to the synergistic effects of MoP nanocrystals, P dopant, and porous carbon, the resulting MoP@PC composite exhibits superior HER catalytic activity with an onset overpotential of 97 mV, a Tafel slope of 59.3 mV dec -1 , and good long-term durability, which compares to those of most reported MoP-based HER catalysts. Most importantly, the work opens a new route in the development of high-performance nonprecious HER electrocatalysts derived from MOFs.
NASA Technical Reports Server (NTRS)
Zhu, Dongming; Harder, Bryan
2016-01-01
Environmental barrier coatings (EBC) and SiCSiC ceramic matrix composites (CMCs) will play a crucial role in future aircraft turbine engine systems, because of their ability to significantly increase engine operating temperatures, reduce engine weight and cooling requirements. This paper presents current NASA EBC-CMC development emphases including: the coating composition and processing improvements, laser high heat flux-thermal gradient thermo-mechanical fatigue - environmental testing methodology development, and property evaluations for next generation EBC-CMC systems. EBCs processed with various deposition techniques including Plasma Spray, Electron Beam - Physical Vapor Deposition, and Plasma Spray Physical Vapor Deposition (PS-PVD) will be particularly discussed. The testing results and demonstrations of advanced EBCs-CMCs in complex simulated engine thermal gradient cyclic fatigue, oxidizing-steam and CMAS environments will help provide insights into the coating development strategies to meet long-term engine component durability goals.
Seventy-five years of aggregate research in Kansas
DOT National Transportation Integrated Search
1999-03-01
The Kansas Department of Transportation (KDOT) has a long history of aggregate research directed towards finding the most reliable and durable aggregate for highway construction. Beginning with a study on freeze thaw durability in 1928, this paper su...
Immediate impact on the rim zone of cement based materials due to chemical attack
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schwotzer, M., E-mail: matthias.schwotzer@kit.edu; Scherer, T.; Gerdes, A.
2015-01-15
Cement based materials are in their widespread application fields exposed to various aqueous environments. This can lead to serious chemical changes affecting the durability of the materials. In particular in the context of service life prediction a detailed knowledge of the reaction mechanisms is a necessary base for the evaluation of the aggressivity of an aqueous medium and this is deduced commonly from long term investigations. However, these processes start immediately at the material/water-interface, when a cementitious system comes into contact with an aqueous solution, altering here the chemical composition and microstructure. This rim zone represents the first hurdle thatmore » has to be overcome by an attacking aqueous solution. Therefore, the properties of the surface near area should be closely associated with the further course of deterioration processes by reactive transport. In this context short term exposure experiments with hardened cement paste over 4 and 48 h have been carried out with demineralized water, hard tap water and different sulfate solutions. In order to investigate immediate changes in the near-surface region, depth profile cuts have been performed on the cement paste samples by means of focused ion beam preparation techniques. A scanning beam of Gallium ions is applied to cut a sharp edge in the cement paste surface, providing insights into the composition and microstructure of the upper ten to hundred microns. Electron microscopic investigations on such a section of the rim zone, together with surface sensitive X-ray diffraction accompanied by a detailed characterization of the bulk composition confirm that the properties of the material/water interface are of relevance for the durability of cement based systems in contact with aqueous solutions. In this manner, focused ion beam investigations constitute auspicious tools to contribute to a more sophisticated understanding of the reaction mechanisms. - Highlights: • The chemical stability is related to the properties of material/water interface. • Properties of the rim zone readjust quickly, triggered by hydrochemical conditions. • Durability research can be improved by combining FIB techniques and common analytics.« less
Durability of Polymer Electrolyte Membrane Fuel Cells Operated at Subfreezing Temperatures
Macauley, Natalia; Lujan, Roger W.; Spernjak, Dusan; ...
2016-09-15
The structure, composition, and interfaces of membrane electrode assemblies (MEA) and gas-diffusion layers (GDLs) have a significant effect on the performance of single-proton-exchange-membrane (PEM) fuel cells operated isothermally at subfreezing temperatures. During isothermal constant-current operation at subfreezing temperatures, water forming at the cathode initially hydrates the membrane, then forms ice in the catalyst layer and/or GDL. This ice formation results in a gradual decay in voltage. High-frequency resistance initially decreases due to an increase in membrane water content and then increases over time as the contact resistance increases. The water/ice holding capacity of a fuel cell decreases with decreasing subfreezingmore » temperature (-10°C vs. -20°C vs. -30°C) and increasing current density (0.02 A cm -2 vs. 0.04 A cm -2). Ice formation monitored using in-situ high-resolution neutron radiography indicated that the ice was concentrated near the cathode catalyst layer at low operating temperatures (≈-20°C) and high current densities (0.04 A cm -2). Significant ice formation was also observed in the GDLs at higher subfreezing temperatures (≈-10°C) and lower current densities (0.02 A cm -2). These results are in good agreement with the long-term durability observations that show more severe degradation at lower temperatures (-20°C and -30°C).« less
Krishnamurthy, Ajay; Hunston, Donald L; Forster, Amanda L; Natarajan, Bharath; Liotta, Andrew H; Wicks, Sunny S; Stutzman, Paul E; Wardle, Brian L; Liddle, J Alexander; Forster, Aaron M
2017-12-01
As carbon nanotube (CNT) infused hybrid composites are increasingly identified as next-generation aerospace materials, it is vital to evaluate their long-term structural performance under aging environments. In this work, the durability of hierarchical, aligned CNT grafted aluminoborosilicate microfiber-epoxy composites (CNT composites) are compared against baseline aluminoborosilicate composites (baseline composites), before and after immersion in water at 25 °C (hydro) and 60 °C (hydrothermal), for extended durations (90 d and 180 d). The addition of CNTs is found to reduce water diffusivities by approximately 1.5 times. The mechanical properties (bending strength and modulus) and the damage sensing capabilities (DC conductivity) of CNT composites remain intact regardless of exposure conditions. The baseline composites show significant loss of strength (44 %) after only 15 d of hydrothermal aging. This loss of mechanical strength is attributed to fiber-polymer interfacial debonding caused by accumulation of water at high temperatures. In situ acoustic and DC electrical measurements of hydrothermally aged CNT composites identify extensive stress-relieving micro-cracking and crack deflections that are absent in the aged baseline composites. These observations are supported by SEM images of the failed composite cross-sections that highlight secondary matrix toughening mechanisms in the form of CNT pullouts and fractures which enhance the service life of composites and maintain their properties under accelerated aging environments.
Takamizawa, Toshiki; Scheidel, Donal D; Barkmeier, Wayne W; Erickson, Robert L; Tsujimoto, Akimasa; Latta, Mark A; Miyazaki, Masashi
2016-09-01
The purpose of this study was to determine the influence of different frequency rates on of bond durability of self-etch adhesives to enamel using shear fatigue strength (SFS) testing. A two-step self-etch adhesive (OX, OptiBond XTR), and two single step self-etch adhesives (GB, G-ӕnial Bond and SU, Scotchbond Universal) were used in this study. The shear fatigue strength (SFS) to enamel was obtained. A staircase method was used to determine the SFS values with 50,000 cycles or until failure occurred. Fatigue testing was performed at frequencies of 5Hz, 10Hz, and 20Hz. For each test condition, 30 specimens were prepared for the SFS testing. Regardless of the bond strength test method, OX showed significantly higher SFS values than the two single-step self-etch adhesives. For each of the three individual self-etch adhesives, there was no significant difference in SFS depending on the frequency rate, although 20Hz results tended to be higher. Regardless of the self-etch adhesive system, frequencies of 5Hz, 10Hz, and 20Hz produced similar results in fatigue strength of resin composite bonded to enamel using 50,000 cycles or until bond failure. Accelerated fatigue testing provides valuable information regarding the long term durability of resin composite to enamel bonding using self-etch adhesive system. Copyright © 2016 Elsevier Ltd. All rights reserved.
Concept definition study of small Brayton cycle engines for dispersed solar electric power systems
NASA Technical Reports Server (NTRS)
Six, L. D.; Ashe, T. L.; Dobler, F. X.; Elkins, R. T.
1980-01-01
Three first-generation Brayton cycle engine types were studied for solar application: a near-term open cycle (configuration A), a near-term closed cycle (configuration B), and a longer-term open cycle (configuration C). A parametric performance analysis was carried out to select engine designs for the three configurations. The interface requirements for the Brayton cycle engine/generator and solar receivers were determined. A technology assessment was then carried out to define production costs, durability, and growth potential for the selected engine types.
[Indications for and clinical outcome of the Ross procedure: a review].
Morita, K; Kurosawa, H
2001-04-01
The Ross procedure has been used increasingly to treat aortic valve disease in children and young adults. The primary indication for the Ross procedure is to provide a permanent valve replacement in children with congenital aortic stenosis. More recently, it has been extended to young adults with a bicuspid aortic valve and small aortic annulus, especially women wishing to have children. Other possible indications include complex left ventricular outflow obstructive disease, native or prosthetic valve endocarditis, and adult aortic insufficiency with a dilated aortic annulus. Conversely, Marfan syndrome is considered to an absolute contraindication, and this procedure should be used with caution in patients with rheumatic valve disease and a dysplastic dilated aortic root because of the higher associated incidence of autograft dysfunction. The technique of total aortic root replacement has become the preferred method of autograft implantation, because it carries the lowest risk of pulmonary autograft failure. In patients with marked graft-host size mismatch, either concomitant aortic annulus reduction and fixation or aortic annulus enlargement (i.e., the Ross-Konno procedure) should be performed. The Ross Procedure International Registry data document that in the modern era (post-1986) the early and late mortality rate is 2.5% and 1%, respectively. Excellent long-term results have been reported, and the benefits of this procedure include optimal hemodynamics, low risk of endocarditis, resistance to infection in patients with active endocarditis, and nonthrombogeneicity and therefore few anticoagulation-related complications. The Ross procedure can be performed with acceptable early and mid-term mortality and excellent autograft durability. Further long-term follow-up will confirm the role of this procedure in patients with various types of aortic valve disease.
Giona, Fiorina; Putti, Maria C; Micalizzi, Concetta; Menna, Giuseppe; Moleti, Maria L; Santoro, Nicola; Iaria, Grazia; Ladogana, Saverio; Burnelli, Roberta; Consarino, Caterina; Varotto, Stefania; Tucci, Francesca; Messina, Chiara; Nanni, Mauro; Diverio, Daniela; Biondi, Andrea; Pession, Andrea; Locatelli, Franco; Piciocchi, Alfonso; Gottardi, Enrico; Saglio, Giuseppe; Foà, Robin
2015-08-01
Imatinib mesylate (IM) is used for the management of childhood chronic myeloid leukaemia (CML). The most effective dosage of IM and its long-term efficacy in children are not well defined. The purpose of this multicentre study is to report on the long-term results of high-dose IM (340 mg/m2 /d) in CML patients in chronic phase (CP-CML) aged <18 years at diagnosis. A total of 47 CP-CML patients with a median age at diagnosis of 11 years 9 months were enrolled in nine Italian centres. Complete cytogenetic response was achieved in 91.5% of the evaluable patients at a median time of 6 months. BCR-ABL1 International Scale ≤ 0.1% (major molecular response; MMR) and ≤0.01% (molecular response; MR) at 12 months were 66.6% and 33%, respectively. During follow-up, MMR and MR were achieved in 78.6% and 61% of children, respectively. IM was safely discontinued in 3 long-term treated children with a durable MR. Twelve patients (eight cytogenetic/molecular responders) underwent stem cell transplantation. The progression-free survival probabilities at 96 months for responding patients who continued IM and for those transplanted were 60% and 50%, respectively. After a median follow-up of 52 months (range 3-146), all patients are alive. High-dose IM is a long-term effective therapy in children and adolescents with CP-CML. © 2015 John Wiley & Sons Ltd.
Wu, Min; Xin, Huolin L.; Wang, Jie; ...
2015-03-13
A nitrogen and sulfur co-doped graphene/carbon black (NSGCB) nanocomposite for the oxygen reduction reaction (ORR) was synthesized through a one-pot annealing of a precursor mixture containing graphene oxide, thiourea, and acidized carbon black (CB). The NSGCB showed excellent performance for the ORR with the onset and half-way potentials at 0.96 V and 0.81 V (vs. RHE), respectively. It is significantly improved over that of the catalysts derived from only graphene (0.90 V and 0.76 V) or carbon nanosphere (0.82 V and 0.74 V). The enhanced catalytic activity on the NSGCB electrode could be attributed to the synergistic effect of N/Smore » co-doping and the enlarged interlayer space resulted from the insertion of carbon nanosphere into the graphene sheets. The four-electron selectivity and the limiting current density of the NSGCB nanocomposite are comparable to that of the commercially Pt/C catalyst. Furthermore, the NSGCB nanocomposite was superior to Pt/C in terms of long-term durability and tolerance to methanol poisoning.« less
Effects of elevated temperature on the viscoplastic modeling of graphite/polymeric composites
NASA Technical Reports Server (NTRS)
Gates, Thomas S.
1991-01-01
To support the development of new materials for the design of next generation supersonic transports, a research program is underway at NASA to assess the long term durability of advanced polymer matrix composites (PMC's). One of main objectives of the program was to explore the effects of elevated temperature (23 to 200 C) on the constitutive model's material parameters. To achieve this goal, test data on the observed nonlinear, stress-strain behavior of IM7/5260 and IM7/8320 composites under tension and compression loading were collected and correlated against temperature. These tests, conducted under isothermal conditions using variable strain rates, included such phenomena as stress relaxation and short term creep. The second major goal was the verification of the model by comparison of analytical predictions and test results for off axis and angle ply laminates. Correlation between test and predicted behavior was performed for specimens of both material systems over a range of temperatures. Results indicated that the model provided reasonable predictions of material behavior in load or strain controlled tests. Periods of loading, unloading, stress relaxation, and creep were accounted for.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ying, Jie; Li, Jing; Jiang, Gaopeng
Pt-based nanomaterials are regarded as the most efficient electrocatalysts for the oxygen reduction reaction (ORR) in proton exchange membrane fuel cells (PEMFCs). However, widespread adoption of PEMFCs requires solutions to major challenges encountered with ORR catalysts, namely high cost, sluggish kinetics, and low durability. In this paper, a new efficient method utilizing Co-based metal-organic frameworks is developed to produce PtCo bimetallic nanoparticles embedded in unique nitrogen-doped hollow porous carbon capsules. The obtained catalyst demonstrates an outstanding ORR performance, with a mass activity that is 5.5 and 13.5 times greater than that of commercial Pt/C and Pt black, respectively. Most importantly,more » the product exhibits dramatically improved durability in terms of both electrochemically active surface area (ECAS) and mass activity compared to commercial Pt/C and Pt black catalysts. Finally, the remarkable ORR performance demonstrated here can be attributed to the structural features of the catalyst (its alloy structure, high dispersion and fine particle size) and the carbon support (its nitrogen dopant, large surface area and hollow porous structure).« less
Ying, Jie; Li, Jing; Jiang, Gaopeng; ...
2017-11-29
Pt-based nanomaterials are regarded as the most efficient electrocatalysts for the oxygen reduction reaction (ORR) in proton exchange membrane fuel cells (PEMFCs). However, widespread adoption of PEMFCs requires solutions to major challenges encountered with ORR catalysts, namely high cost, sluggish kinetics, and low durability. In this paper, a new efficient method utilizing Co-based metal-organic frameworks is developed to produce PtCo bimetallic nanoparticles embedded in unique nitrogen-doped hollow porous carbon capsules. The obtained catalyst demonstrates an outstanding ORR performance, with a mass activity that is 5.5 and 13.5 times greater than that of commercial Pt/C and Pt black, respectively. Most importantly,more » the product exhibits dramatically improved durability in terms of both electrochemically active surface area (ECAS) and mass activity compared to commercial Pt/C and Pt black catalysts. Finally, the remarkable ORR performance demonstrated here can be attributed to the structural features of the catalyst (its alloy structure, high dispersion and fine particle size) and the carbon support (its nitrogen dopant, large surface area and hollow porous structure).« less
Deo, Salil V; Altarabsheh, Salah E; Shah, Ishan K; Cho, Yang Hyun; McGraw, Michael; Sarayyepoglu, Basar; Medalion, Benjamin; Markowitz, Alan H; Park, Soon J
2015-04-01
Bilateral internal thoracic artery grafting appears to be the preferred method to achieve durable long-term coronary artery revascularization. However, data reporting the benefit of this technique in the elderly is very conflicting. We performed a systematic review of available literature (till November 2014) using multiple databases to identify studies comparing clinical events in patients undergoing coronary artery bypass grafting using either a single or double internal thoracic artery in the elderly. While early mortality was the primary end-point of inclusion, other adverse events compared were sternal wound infection (deep and superficial), stroke and peri-operative myocardial infarction. Individual and pooled odd's ratios were calculated using the Mantel-Haenzel method (random effect model); sensitivity analysis was performed. Results are presented using 95% confidence intervals. Nine retrospective studies (4479 BITA, 7733 LITA patients) fulfilled search criteria. Deep sternal wound infection was significantly higher after BITA harvest [OR 1.86 (1.3-2.5); I(2) = 0%; p < 0.01]. Early mortality (BITA 3.6% vs SITA 3.1%; p = 0.86), stroke [OR 0.7(0.4-1.1); p = 0.1], and peri-operative myocardial infarction (BITA 4.3% vs SITA 2.3%; p = 0.1) were comparable in both cohorts. Long-term survival favored the BITA cohort in two propensity matched studies. The incidence of deep sternal wound infection may be significantly higher after the harvest of both internal thoracic arteries in the elderly. While other post-operative adverse events are comparable, data regarding the long-term survival advantage in this cohort is conflicting. Hence, the use of both internal thoracic arteries in this age group needs to be invidualized. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.
Bond durability of universal adhesive to bovine enamel using self-etch mode.
Suzuki, Soshi; Takamizawa, Toshiki; Imai, Arisa; Tsujimoto, Akimasa; Sai, Keiichi; Takimoto, Masayuki; Barkmeier, Wayne W; Latta, Mark A; Miyazaki, Masashi
2018-04-01
The purpose of this study was to examine the enamel bond durability of universal adhesives in the self-etch mode under 2-year water storage and thermal cycling conditions. Three commercially available universal adhesives and a gold standard two-step self-etch adhesive were used. Ten specimens of bovine enamel were prepared per test group, and shear bond strength (SBS) was measured to determine the bonding durability after thermal cycling (TC) or long-term water storage (WS). The bonded specimens were divided into three groups: (1) specimens subjected to TC, where the bonded specimens were stored in 37 °C distilled water for 24 h before being subjected to 3000, 10,000, 20,000 or 30,000 TC; (2) specimens stored in 37 °C distilled water for 3 months, 6 months, 1 year or 2 year; and (3) specimens stored in 37 °C distilled water for 24 h, serving as a baseline. The two-step self-etch adhesive showed significantly higher SBS than the universal adhesives tested, regardless of the type of degradation method. All universal adhesives showed no significant enamel SBS reductions in TC and WS, when compared to baseline and the other degradation conditions. Compared to the bond strengths obtained with the two-step self-etch adhesive, significantly lower bond strengths were obtained with universal adhesives. However, the enamel bond durability of universal adhesives was relatively stable under both degradation conditions tested. The present data indicate that the enamel bond durability of universal adhesives in the self-etch mode might be sufficient for clinical use.
NanoSIMS Imaging Alternation Layers of a Leached SON68 Glass Via A FIB-made Wedged Crater
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Yi-Chung; Schreiber, Daniel K.; Neeway, James J.
2014-11-01
Currently, nuclear wastes are commonly immobilized into glasses because of their long-term durability. Exposure to water for long periods of time, however, will eventually corrode the waste form and is the leading potential avenue for radionuclide release into the environment. Because such slow processes cannot be experimentally tested, the prediction of release requires a thorough understanding the mechanisms governing glass corrosion. In addition, due to the exceptional durability of glass, much of the testing must be performed on high-surface-area powders. A technique that can provide accurate compositional profiles with very precise depth resolution for non-flat samples would be a majormore » benefit to the field. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) depth profiling is an excellent tool that has long been used to examine corrosion layers of glass. The roughness of the buried corrosion layers, however, causes the corresponding SIMS depth profiles to exhibit erroneously wide interfaces. In this study, NanoSIMS was used to image the cross-section of the corrosion layers of a leached SON68 glass sample. A wedged crater was prepared by a focused ion beam (FIB) instrument to obtain a 5× improvement in depth resolution for NanoSIMS measurements. This increase in resolution allowed us to confirm that the breakdown of the silica glass network is further from the pristine glass than a second dissolution front for boron, another glass former. The existence of these two distinct interfaces, separated by only ~20 nm distance in depth, was not apparent by traditional ToF-SIMS depth profiling but has been confirmed also by atom probe tomography. This novel sample geometry will be a major benefit to efficient NanoSIMS sampling of irregular interfaces at the nanometer scale that would otherwise be obscured within ToF-SIMS depth profiles.« less
Educational Furniture for the 16-19 Age Group: Specification and Design. Design Note 30.
ERIC Educational Resources Information Center
Furniture Industry Research Association, Stevenage (England).
A 1982 British study examined the furniture needs of 16-19 year-old students. This report presented the findings on the technical and performance requirements in terms of durability and ergonomics. This report examines the furniture requirements in teaching spaces, social, refreshment and private study areas, storage requirements for pupils'…
Application of High Performance Computing for Simulations of N-Dodecane Jet Spray with Evaporation
2016-11-01
sprays and develop a predictive theory for comparison to measurements in the laboratory of turbulent diesel sprays. 15. SUBJECT TERMS high...models into future simulations of turbulent jet sprays and develop a predictive theory for comparison to measurements in the lab of turbulent diesel ...A critical component of maintaining performance and durability of a diesel engine involves the formation of a fuel-air mixture as a diesel jet spray
Generation of a functional and durable vascular niche by the adenoviral E4ORF1 gene
Seandel, Marco; Butler, Jason M.; Kobayashi, Hideki; Hooper, Andrea T.; White, Ian A.; Zhang, Fan; Vertes, Eva L.; Kobayashi, Mariko; Zhang, Yan; Shmelkov, Sergey V.; Hackett, Neil R.; Rabbany, Sina; Boyer, Julie L.; Rafii, Shahin
2008-01-01
Vascular cells contribute to organogenesis and tumorigenesis by producing unknown factors. Primary endothelial cells (PECs) provide an instructive platform for identifying factors that support stem cell and tumor homeostasis. However, long-term maintenance of PECs requires stimulation with cytokines and serum, resulting in loss of their angiogenic properties. To circumvent this hurdle, we have discovered that the adenoviral E4ORF1 gene product maintains long-term survival and facilitates organ-specific purification of PECs, while preserving their vascular repertoire for months, in serum/cytokine-free cultures. Lentiviral introduction of E4ORF1 into human PECs (E4ORF1+ ECs) increased the long-term survival of these cells in serum/cytokine-free conditions, while preserving their in vivo angiogenic potential for tubulogenesis and sprouting. Although E4ORF1, in the absence of mitogenic signals, does not induce proliferation of ECs, stimulation with VEGF-A and/or FGF-2 induced expansion of E4ORF1+ ECs in a contact-inhibited manner. Indeed, VEGF-A-induced phospho MAPK activation of E4ORF1+ ECs is comparable with that of naive PECs, suggesting that the VEGF receptors remain functional upon E4ORF1 introduction. E4ORF1+ ECs inoculated in implanted Matrigel plugs formed functional, patent, humanized microvessels that connected to the murine circulation. E4ORF1+ ECs also incorporated into neo-vessels of human tumor xenotransplants and supported serum/cytokine-free expansion of leukemic and embryonal carcinoma cells. E4ORF1 augments survival of PECs in part by maintaining FGF-2/FGF-R1 signaling and through tonic Ser-473 phosphorylation of Akt, thereby activating the mTOR and NF-κB pathways. Therefore, E4ORF1+ ECs establish an Akt-dependent durable vascular niche not only for expanding stem and tumor cells but also for interrogating the roles of vascular cells in regulating organ-specific vascularization and tumor neo-angiogenesis. PMID:19036927
Long-term durability of sacral nerve stimulation therapy for chronic fecal incontinence.
Hull, Tracy; Giese, Chad; Wexner, Steven D; Mellgren, Anders; Devroede, Ghislain; Madoff, Robert D; Stromberg, Katherine; Coller, John A
2013-02-01
Limited data have been published regarding the long-term results of sacral nerve stimulation, or sacral neuromodulation, for severe fecal incontinence. The aim was to assess the outcome of sacral nerve stimulation with the use of precise tools and data collection, focusing on the long-term durability of the therapy. Five-year data were analyzed. Patients entered in a multicenter, prospective study for fecal incontinence were followed at 3, 6, and 12 months and annually after device implantation. Patients with chronic fecal incontinence in whom conservative treatments had failed or who were not candidates for more conservative treatments were selected. Patients with ≥ 50% improvement over baseline in fecal incontinence episodes per week during a 14-day test stimulation period received sacral nerve stimulation therapy. Patients were assessed with a 14-day bowel diary and Fecal Incontinence Quality of Life and Fecal Incontinence Severity Index questionnaires. Therapeutic success was defined as ≥ 50% improvement over baseline in fecal incontinence episodes per week. All adverse events were collected. A total of 120 patients (110 women; mean age, 60.5 years) underwent implantation. Seventy-six of these patients (63%) were followed a minimum of 5 years (maximum, longer than 8 years) and are the basis for this report. Fecal incontinence episodes per week decreased from a mean of 9.1 at baseline to 1.7 at 5 years, with 89% (n = 64/72) having ≥ 50% improvement (p < 0.0001) and 36% (n = 26/72) having complete continence. Fecal Incontinence Quality of Life scores also significantly improved for all 4 scales between baseline and 5 years (n = 70; p < 0.0001). Twenty-seven of the 76 (35.5%) patients required a device revision, replacement, or explant. The therapeutic effect and improved quality of life for fecal incontinence is maintained 5 years after sacral nerve stimulation implantation and beyond. Device revision, replacement, or explant rate was acceptable, but future efforts should be aimed at improvement.
Bourguignon, Thierry; Espitalier, Fabien; Pantaleon, Clémence; Vermes, Emmanuelle; El-Arid, Jean Marc; Loardi, Claudia; Karam, Elias; Candolfi, Pascal; Ivanes, Fabrice; Aupart, Michel
2018-02-12
Mitral valve replacement using a bioprosthesis remains controversial in young patients because data on long-term outcomes are missing. This study evaluated the long-term results of the PERIMOUNT pericardial mitral bioprosthesis in patients aged 65 years or younger. From 1984 to 2010, 148 Carpentier-Edwards PERIMOUNT mitral bioprostheses were implanted in 148 patients aged 65 years or younger. Baseline clinical, perioperative and follow-up data were recorded prospectively. Structural valve deterioration (SVD) was defined by strict echocardiographic assessment. The mean follow-up period was 8.6 ± 5.5 years, for a total of 1269 valve-years. Operative mortality rate was 2.0%. Fifty-one late deaths occurred (linearized rate 4.0% per valve-year). Actuarial survival rates averaged 70 ± 4%, 53 ± 6% and 31 ± 7% after 10, 15 and 20 years of follow-up, respectively. Actuarial freedom from SVD at 10, 15 and 20 years was 78 ± 5%, 47 ± 7% and 19 ± 7%, respectively. Reoperation was associated with no operative mortality. Actuarial freedom from reoperation due to SVD at 10, 15 and 20 years was 82 ± 4%, 50 ± 6% and 25 ± 8%, respectively. Competing risk analysis demonstrated an actual risk of explantation secondary to SVD at 20 years of 44 ± 5%. Expected valve durability was 14.2 years for this age group. In the selected patients aged 65 years or younger undergoing mitral valve replacement with a pericardial bioprosthesis, the expected valve durability was 14.2 years. Reoperation for SVD was associated with a low risk of mortality. © The Author(s) 2018. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Generation of a functional and durable vascular niche by the adenoviral E4ORF1 gene.
Seandel, Marco; Butler, Jason M; Kobayashi, Hideki; Hooper, Andrea T; White, Ian A; Zhang, Fan; Vertes, Eva L; Kobayashi, Mariko; Zhang, Yan; Shmelkov, Sergey V; Hackett, Neil R; Rabbany, Sina; Boyer, Julie L; Rafii, Shahin
2008-12-09
Vascular cells contribute to organogenesis and tumorigenesis by producing unknown factors. Primary endothelial cells (PECs) provide an instructive platform for identifying factors that support stem cell and tumor homeostasis. However, long-term maintenance of PECs requires stimulation with cytokines and serum, resulting in loss of their angiogenic properties. To circumvent this hurdle, we have discovered that the adenoviral E4ORF1 gene product maintains long-term survival and facilitates organ-specific purification of PECs, while preserving their vascular repertoire for months, in serum/cytokine-free cultures. Lentiviral introduction of E4ORF1 into human PECs (E4ORF1(+) ECs) increased the long-term survival of these cells in serum/cytokine-free conditions, while preserving their in vivo angiogenic potential for tubulogenesis and sprouting. Although E4ORF1, in the absence of mitogenic signals, does not induce proliferation of ECs, stimulation with VEGF-A and/or FGF-2 induced expansion of E4ORF1(+) ECs in a contact-inhibited manner. Indeed, VEGF-A-induced phospho MAPK activation of E4ORF1(+) ECs is comparable with that of naive PECs, suggesting that the VEGF receptors remain functional upon E4ORF1 introduction. E4ORF1(+) ECs inoculated in implanted Matrigel plugs formed functional, patent, humanized microvessels that connected to the murine circulation. E4ORF1(+) ECs also incorporated into neo-vessels of human tumor xenotransplants and supported serum/cytokine-free expansion of leukemic and embryonal carcinoma cells. E4ORF1 augments survival of PECs in part by maintaining FGF-2/FGF-R1 signaling and through tonic Ser-473 phosphorylation of Akt, thereby activating the mTOR and NF-kappaB pathways. Therefore, E4ORF1(+) ECs establish an Akt-dependent durable vascular niche not only for expanding stem and tumor cells but also for interrogating the roles of vascular cells in regulating organ-specific vascularization and tumor neo-angiogenesis.
NASA Astrophysics Data System (ADS)
Wu, Xiaoyan; Tian, Yu; Zhang, Jun; Zuo, Wei; Kong, Xiaowei; Wang, Jinghui; Sun, Kening; Zhou, Xiaoliang
2016-01-01
In this paper, silver (Ag) particles are introduced into the conventional Ni/YSZ anode by utilizing electroless plating method to improve its carbon anti-coking ability in hydrocarbons. The experimental results show that electrochemical performances of the decorated cells in H2, CH4 and C2H6 are all increased as compared to the cell with unmodified Ni/YSZ anode, which are verified by impedance spectrums as well. The durability experiment is carried out for as long as 24 h at the current density of 0.33 A/cm2 where the modified anode is subjected to dry C2H6 indicating the anti-coking ability of the anode is greatly improved. Scanning electron microscope shows that the slight decreasing in the cell terminal voltage can be attributed to the minimized carbon deposition which maybe resulted from the aggregation of silver particles at high temperature. Energy-dispersive X-ray spectroscopy line scanning results after long-term stability operation of the anode suggest that the carbon deposition can be depressed effectively both inside the anode and on the surface of the anode. Therefore, the results show that silver is a promising candidate material for modifying the Ni/YSZ anode with regard to improving electrochemical performance and suppressing the carbon deposition when taking the hydrocarbons as fuels.
Extending battery life: A low-cost practical diagnostic technique for lithium-ion batteries
NASA Astrophysics Data System (ADS)
Merla, Yu; Wu, Billy; Yufit, Vladimir; Brandon, Nigel P.; Martinez-Botas, Ricardo F.; Offer, Gregory J.
2016-11-01
Modern applications of lithium-ion batteries such as smartphones, hybrid & electric vehicles and grid scale electricity storage demand long lifetime and high performance which typically makes them the limiting factor in a system. Understanding the state-of-health during operation is important in order to optimise for long term durability and performance. However, this requires accurate in-operando diagnostic techniques that are cost effective and practical. We present a novel diagnosis method based upon differential thermal voltammetry demonstrated on a battery pack made from commercial lithium-ion cells where one cell was deliberately aged prior to experiment. The cells were in parallel whilst being thermally managed with forced air convection. We show for the first time, a diagnosis method capable of quantitatively determining the state-of-health of four cells simultaneously by only using temperature and voltage readings for both charge and discharge. Measurements are achieved using low-cost thermocouples and a single voltage measurement at a frequency of 1 Hz, demonstrating the feasibility of implementing this approach on real world battery management systems. The technique could be particularly useful under charge when constant current or constant power is common, this therefore should be of significant interest to all lithium-ion battery users.
Aggregate Freezing-Thawing Performance Using the Iowa Pore Index : final report.
DOT National Transportation Integrated Search
2016-10-01
In cold climates, the use of non-durable aggregate leads to premature pavement deterioration due to damage caused by freezing-thawing cycles. Differentiating durable and non-durable aggregates is a crucial yet challenging task. The frost durability o...
Microclimatic Variation Within Sleeve Cages Used in Ecological Studies
Nelson, Lori A.; Rieske, Lynne K.
2014-01-01
Abstract Sleeve cages for enclosing or excluding arthropods are essential components of field studies evaluating trophic interactions. Microclimatic variation in sleeve cages was evaluated to characterize its potential effects on subsequent long-term experiments. Two sleeve cage materials, polyester and nylon, and two cage sizes, 400 and 6000 cm 2 , were tested on eastern hemlock, Tsuga canadensis (L.) Carrière. Temperature and relative humidity inside and outside cages, and the cost and durability of the cage materials, were compared. Long-term effects of the sleeve cages were observed by measuring new growth on T. canadensis branches. The ultimate goal was to identify a material that minimizes bag-induced microclimatic variation. Bagged branches whose microclimates mimic those of surrounding unbagged branches should have minimal effects on plant growth and may prove ideal venues for assessing herbivore and predator behavior under natural conditions. No differences were found in temperature or humidity between caging materials. Small cages had higher average temperatures than large cages, especially in the winter, but this difference was confounded by the fact that small cages were positioned higher in trees than large cages. Differences in plant growth were detected. Eastern hemlock branches enclosed within polyester cages produced fewer new growth tips than uncaged controls. Both polyester and nylon cages reduced the length of new shoot growth relative to uncaged branches. In spite of higher costs, nylon cages were superior to polyester with respect to durability and ease of handling. PMID:25368083
Effect of Hydrofluoric Acid Concentration on Resin Adhesion to a Feldspathic Ceramic.
Venturini, Andressa Borin; Prochnow, Catina; Rambo, Dagma; Gundel, Andre; Valandro, Luiz Felipe
2015-08-01
To evaluate the effect of different concentrations of hydrofluoric acid (HF) on the contact angle and the resin bond strength durability to feldspathic ceramic. To evaluate the contact angles of distilled water on etched feldspathic ceramic, 25 specimens (12×10×2.4 mm) of VitaBlocks Mark II were used, divided into 5 groups (n=5): one unconditioned control (UC) group with no ceramic surface treatment, and 4 other groups that were etched for 60 s with different concentrations of HF: 1% (HF1), 3% (HF3), 5% (HF5) and 10% (HF10). The bond testing utilized 40 ceramic blocks (12×10×4 mm) that were fabricated and subjected to the same surface treatments as previously mentioned (excluding the control). The etched surfaces were silanized and resin cement was applied. After 24 h, the blocks were sectioned to produce bar specimens that were divided into two groups, non-aged (immediate testing) and aged (storage for 230 days+12,000 thermocycles at 5°C and 55°C), and subjected to microtensile testing (μTBS). Micromorphogical analysis of the treated surfaces was also performed (atomic force and scanning electron microscopy). One-way ANOVA and Tukey's tests were applied for data analysis. UC had the highest contact angle (61.4°), whereas HF10 showed the lowest contact angle (17.5°). In non-aged conditions, different acids promoted statistically similar bond strengths (14.2 to 15.7 MPa) (p>0.05); in terms of bond durability, only the bond strength of the HF1 group presented a statistically significant decrease comparing before and after aging (14.5 to 10.2 MPa). When etched with 3%, 5%, or 10% hydrofluoric acid, the ceramic tested showed stable resin adhesion after long-term aging.
Modular bicompartmental knee arthroplasty : Indications, technique, prosthetic design, and results.
Kanna, R
2017-03-01
The shifting demographics of patients with localized knee arthritis, including younger, more active patients, is a chief motivation for mounting interest in tissue preserving surgical substitutes for total knee arthroplasty (TKA). Unlinked, modular bi-compartmental knee arthroplasty (MBKA) is an emerging knee-resurfacing approach that provides a conservative alternative to TKA. Arthritis involving both patellofemoral and either medial or lateral tibiofemoral compartments, with no significant deformity or bone deficiency, preserved motion, and intact cruciate ligaments, can be effectively managed with MBKA. It is tailored to treat the pathologic areas of knees with bicompartmental arthritis with the benefit of improved function and tissue conservation. MBKA done in appropriate patients, using precise technique, with appropriate implants has shown to give good short and long term functional results. Long term results using modern MBKA implants are awaited and may further establish the durability and success of the procedure.
NASA Technical Reports Server (NTRS)
Bowles, Kenneth J.; Tsuji, Luis; Kamvouris, John; Roberts, Gary D.
2003-01-01
A cooperative program was conducted with the General Electric Aircraft Engines plant in Evendale, Ohio, to study the effects of long-term isothermal aging at elevated temperatures on compression and thermal durability properties of T650 35 fabric-reinforced PMR 15 composites. This degradation study was conducted over an approximate time period of 3 1/2 yr. The aging temperatures were 204, 260, 288, 316, and 343 C. Specimens of different dimensions were evaluated. Specimens with ratios of the cut edge to total surface area of 0.03 to 0.89 were fabricated and aged. The aged and unaged specimens were tested in compression as specified in Test Method for Compressive Properties of Rigid Plastics (ASTM D695M). Thickness changes, degraded surface layer growth, weight loss, and failure modes were monitored and recorded. All property changes were thickness dependent.
Direct visual internal urethrotomy: Is it a durable treatment option?
Pal, Dilip Kumar; Kumar, Sanjay; Ghosh, Bastab
2017-01-01
Objective: To evaluate the long-term success rate of direct vision internal urethrotomy as a treatment for anterior urethral strictures. Materials and Methods: We retrospectively analyzed the results for patients who underwent internal urethrotomy from January 2009 to January 2014 for anterior urethral strictures. Patients were followed till January 2016. Patients with complicated urethral strictures with a history of previous urethroplasty, hypospadias repair, or previous radiation were excluded from the study, as anticipated low success rate of direct visual internal urethrotomy (DVIU) in these patients. The Kaplan–Meier method was used to analyze stricture-free probability after the first, second, and third urethrotomy. Results: A total of 186 patients were included in this study. Stricture-free rates after first, second, and third urethrotomy were 29.66%, 22.64%, and 13.33%, respectively. Conclusions: Although DVIU may be a management option for anterior urethral stricture disease, it seems that long-term results are disappointing. PMID:28216923
Direct visual internal urethrotomy: Is it a durable treatment option?
Pal, Dilip Kumar; Kumar, Sanjay; Ghosh, Bastab
2017-01-01
To evaluate the long-term success rate of direct vision internal urethrotomy as a treatment for anterior urethral strictures. We retrospectively analyzed the results for patients who underwent internal urethrotomy from January 2009 to January 2014 for anterior urethral strictures. Patients were followed till January 2016. Patients with complicated urethral strictures with a history of previous urethroplasty, hypospadias repair, or previous radiation were excluded from the study, as anticipated low success rate of direct visual internal urethrotomy (DVIU) in these patients. The Kaplan-Meier method was used to analyze stricture-free probability after the first, second, and third urethrotomy. A total of 186 patients were included in this study. Stricture-free rates after first, second, and third urethrotomy were 29.66%, 22.64%, and 13.33%, respectively. Although DVIU may be a management option for anterior urethral stricture disease, it seems that long-term results are disappointing.
Fiber-optic miniature sensor for in situ temperature monitoring of curing composite material
NASA Astrophysics Data System (ADS)
Sampath, Umesh; Kim, Dae-gil; Kim, Hyunjin; Song, Minho
2018-04-01
This study proposes a fiber-optic temperature sensor with a single-mode fiber tip covered with a thermo-sensitive polymer resin. The temperature is sensed by measuring the Fresnel reflection from the optical fiber/polymer interface. Because the thermo-optic coefficients differ between the optical fiber and the polymer, the in situ temperature can be measured even in curing composite materials. In initial experiments, the proposed sensor successfully measured and recovered the temperature information. The measured sensor data were linearly correlated, with an R2 exceeding 0.99. The standard deviation in the long-term measurements of constant temperature was 2.6%. The durability and stability of the sensor head material in long-term operation was validated by Fourier transform infrared spectroscopy and X-ray diffraction analysis. In further experiments, the suggested miniature temperature sensor obtained the internal temperatures of curing composite material over a wide range (30-110 °C).
A multifunctional polymeric nanofilm with robust chemical performances for special wettability.
Wang, Yabin; Lin, Feng; Dong, Yaping; Liu, Zhong; Li, Wu; Huang, Yudong
2016-03-07
A multifunctional polymeric nanofilm of a triazinedithiolsilane compound, which can protect metallic substrates and activate the corresponding surface simultaneously, is introduced onto a copper mesh surface via facile solution-immersion approaches. The resultant interface exhibits hydrophilic features due to the existence of silanol groups (SiOH) outward and has the potential to act as a superhydrophilic and underwater superoleophobic material. As the polymeric nanofilm atop the copper mesh is modified with long-chain octadecyltrichlorosilane (OTS), the functionalized surface becomes superhydrophobic and superoleophilic. The OTS-modified polymeric nanofilm shows outstanding chemical durability and stability that are seldom concurrently satisfied for a material with special wettability, owing to its inherent architecture. These textures generate high separation efficiency, durable separation capability and excellent thermal stability. The protective ability, originating from the textures of the underlying cross-linked disulfide units (-SS-) and siloxane networks (SiOSi) on the top of the nanofilm, prolongs the chemical durability. The activating capability stemming from the residual SiOH groups improves the chemical stability as a result of the chemical bonds developed by these sites. The significant point of this investigation lies in enlightening us on the fabrication of multifunctional polymeric nanofilms on different metal surfaces using various triazinedithiolsilane compounds, and on the construction of interfaces with controllable wettable performances in demanding research or industrial applications.
Durability of aneurysm treatments in patients with active Behcet's disease.
Elsharawy, Mohamed A; Elsaid, Aymen; Al-Dhafery, Bander; Alghnimi, Ibrahim; Almabyouq, Fatimah
2016-10-01
Aneurysms in Behcet's disease are rare, serious, and recurrent. To achieve durable treatment, patients should receive immunosuppressive therapy before intervention to induce remission. We present early and long-term results of emergency cases of active Behcet's disease, which did not permit waiting for suppressive treatment. The study was undertaken on all cases admitted to the vascular unit, King Fahd Hospital of University for aneurysm treatment in patients with active Behcet's disease over about 10 years. All patients had exclusion of the aneurysm either by open surgery or endovascular intervention. Morbidities and mortality were recorded within the hospital admission and on the follow-up. During the study period, three cases were included. All interventions were successful and lifesaving. However, two cases, treated with surgical interposition grafts, were blocked in the intermediate term follow-up (2-12 months) and one case, treated with endovascular treatment, complicated with pseudoaneurysm at femoral puncture site after six months. Although early results were good, intermediate ones were not satisfactory because of progressive graft thrombosis and formation of new aneurysms. Awareness of these rare cases help for early identification and proper immunosuppressive before emergency vascular intervention is warranted. © The Author(s) 2015.
Liu, Xin; Wang, Wei; Wang, Yang; Wang, Yuexiang; Li, Qiuyang; Tang, Jie
2016-01-01
The long-term outcomes of ultrasound-guided high-intensity focused ultrasound (USgHIFU) ablation treatment for adenomyosis and the relevant factors affecting the durability of symptom relief were assessed in this study.A total of 230 women with adenomyosis who were treated with USgHIFU ablation between January 2007 and December 2013 were retrospectively analyzed. The contrast-enhanced ultrasonography (CEUS) was performed immediately after the treatment to evaluate the ablation effect, and the nonperfused volume (NPV) ratio was then calculated. Regular follow-up was conducted and the visual analog scale (VAS) score was used to assess the changes in dysmenorrhea. The effect of treatment was evaluated after an average follow-up length of 3 months and the factors affecting clinical success and symptom relapse were identified.Of the 230 treated patients, 208 (90.4%) were followed up regularly, with a median follow-up length of 40 months (range, 18-94 months). Mean value of the NPV ratio calculated immediately after the treatment was 57.4 ± 24.4%. Varying degrees of symptomatic relief of dysmenorrhea based on the VAS scores were observed in 173 (83.2%) patients and 71.0% of the patients were asymptomatic during follow-up. Women with higher NPV ratio (OR = 0.964, 95% CI = 0.947-0.982, P = 0.000) and older age (OR = 0.342, 95% CI = 0.143-0.819, P = 0.016) were more likely to achieve clinical success. Dysmenorrhea recurred in 45 (26%) out of 173 cases; the median recurrence time was 12 months after treatment. The lower BMI (OR = 1.221, 95% CI = 1.079-1.381, P = 0.001) and the higher acoustic power (OR = 0.992, 95% CI = 0.986-0.998, P = 0.007) were associated with less risk of relapse. Twelve of the 14 patients who were retreated by USgHIFU ablation after experiencing dysmenorrhea recurrence achieved clinical success.USgHIFU ablation is an effective uterus-conserving treatment for symptomatic adenomyosis with an acceptable long-term success rate. Higher chance of clinical success can be achieved in patients with larger NPV ratio and older age, whereas higher BMI and lower acoustic power may result in a higher chance of recurrence. These factors are helpful in selecting suitable patients for USgHIFU and in predicting the durability of symptom relief.
Liu, Xin; Wang, Wei; Wang, Yang; Wang, Yuexiang; Li, Qiuyang; Tang, Jie
2016-01-01
Abstract The long-term outcomes of ultrasound-guided high-intensity focused ultrasound (USgHIFU) ablation treatment for adenomyosis and the relevant factors affecting the durability of symptom relief were assessed in this study. A total of 230 women with adenomyosis who were treated with USgHIFU ablation between January 2007 and December 2013 were retrospectively analyzed. The contrast-enhanced ultrasonography (CEUS) was performed immediately after the treatment to evaluate the ablation effect, and the nonperfused volume (NPV) ratio was then calculated. Regular follow-up was conducted and the visual analog scale (VAS) score was used to assess the changes in dysmenorrhea. The effect of treatment was evaluated after an average follow-up length of 3 months and the factors affecting clinical success and symptom relapse were identified. Of the 230 treated patients, 208 (90.4%) were followed up regularly, with a median follow-up length of 40 months (range, 18–94 months). Mean value of the NPV ratio calculated immediately after the treatment was 57.4 ± 24.4%. Varying degrees of symptomatic relief of dysmenorrhea based on the VAS scores were observed in 173 (83.2%) patients and 71.0% of the patients were asymptomatic during follow-up. Women with higher NPV ratio (OR = 0.964, 95% CI = 0.947–0.982, P = 0.000) and older age (OR = 0.342, 95% CI = 0.143–0.819, P = 0.016) were more likely to achieve clinical success. Dysmenorrhea recurred in 45 (26%) out of 173 cases; the median recurrence time was 12 months after treatment. The lower BMI (OR = 1.221, 95% CI = 1.079–1.381, P = 0.001) and the higher acoustic power (OR = 0.992, 95% CI = 0.986–0.998, P = 0.007) were associated with less risk of relapse. Twelve of the 14 patients who were retreated by USgHIFU ablation after experiencing dysmenorrhea recurrence achieved clinical success. USgHIFU ablation is an effective uterus-conserving treatment for symptomatic adenomyosis with an acceptable long-term success rate. Higher chance of clinical success can be achieved in patients with larger NPV ratio and older age, whereas higher BMI and lower acoustic power may result in a higher chance of recurrence. These factors are helpful in selecting suitable patients for USgHIFU and in predicting the durability of symptom relief. PMID:26817877
Schadendorf, Dirk; Hodi, F. Stephen; Robert, Caroline; Weber, Jeffrey S.; Margolin, Kim; Hamid, Omid; Patt, Debra; Chen, Tai-Tsang; Berman, David M.; Wolchok, Jedd D.
2015-01-01
Purpose To provide a more precise estimate of long-term survival observed for ipilimumab-treated patients with advanced melanoma, we performed a pooled analysis of overall survival (OS) data from multiple studies. Methods The primary analysis pooled OS data for 1,861 patients from 10 prospective and two retrospective studies of ipilimumab, including two phase III trials. Patients were previously treated (n = 1,257) or treatment naive (n = 604), and the majority of patients received ipilimumab 3 mg/kg (n = 965) or 10 mg/kg (n = 706). We also conducted a secondary analysis of OS data (n = 4,846) with an additional 2,985 patients from an expanded access program. OS rates were estimated using the Kaplan-Meier method. Results Among 1,861 patients, median OS was 11.4 months (95% CI, 10.7 to 12.1 months), which included 254 patients with at least 3 years of survival follow-up. The survival curve began to plateau around year 3, with follow-up of up to 10 years. Three-year survival rates were 22%, 26%, and 20% for all patients, treatment-naive patients, and previously treated patients, respectively. Including data from the expanded access program, median OS was 9.5 months (95% CI, 9.0 to 10.0 months), with a plateau at 21% in the survival curve beginning around year 3. Conclusion To our knowledge, this is the largest analysis of OS to date for ipilimumab-treated patients with advanced melanoma. We observed a plateau in the survival curve, beginning at approximately 3 years, which was independent of prior therapy or ipilimumab dose. These data add to the evidence supporting the durability of long-term survival in ipilimumab-treated patients with advanced melanoma. PMID:25667295
Choi, Kyu-Sun; Ko, Yong; Kim, Young-Soo; Yi, Hyeong-Joong
2015-01-01
Occipital neuralgia is a rare cause of severe headache characterized by paroxysmal shooting or stabbing pain in the distribution of the greater occipital or lesser occipital nerve. In cases of intractable occipital neuralgia, a definite cause has not been uncovered, so various types of treatment have been applied. The aim of this study is to evaluate the prognostic factors, safety, and long-term clinical efficacy of second cervical (C2) ganglion decompression for intractable occipital neuralgia. Retrospective analysis was performed in 68 patients with medically refractory occipital neuralgia who underwent C2 ganglion decompression. Factors based on patients' demography, pre- and postoperative headache severity/characteristics, medication use, and postoperative complications were investigated. Therapeutic success was defined as pain relief by at least 50 % without ongoing medication. The visual analog scale (VAS) score was significantly reduced between the preoperative and most recent follow-up period. One year later, excellent or good results were achieved in 57 patients (83.9 %), but poor in 11 patients (16.1 %). The long-term outcome after 5 years was only slightly less than the 1-year outcome; 47 of the 68 patients (69.1 %) obtained therapeutic success. Longer duration of headache (over 13 years; p = 0.029) and presence of retro-orbital/frontal radiation (p = 0.040) were significantly associated with poor prognosis. In the current study, C2 ganglion decompression provided durable, adequate pain relief with minimal complications in patients suffering from intractable occipital neuralgia. Due to the minimally invasive and nondestructive nature of this surgical procedure, C2 ganglion decompression is recommended as an initial surgical treatment option for intractable occipital neuralgia before attempting occipital nerve stimulation. However, further study is required to manage the pain recurrence associated with longstanding nerve injury.
Demark-Wahnefried, Wendy; Morey, Miriam C.; Sloane, Richard; Snyder, Denise C.; Miller, Paige E.; Hartman, Terryl J.; Cohen, Harvey J.
2012-01-01
Purpose Diet and exercise interventions have been tested in cancer survivors as a means to reduce late effects and comorbidity, but few have assessed adherence and health outcomes long term. Methods Between July 2005 and May 2007, the Reach Out to Enhance Wellness (RENEW) trial accrued 641 locoregionally staged, long-term (≥ 5 years from diagnosis) colorectal, breast, and prostate cancer survivors in the United States (21 states), Canada, and the United Kingdom. All participants were sedentary (< 150 minutes of physical activity [PA] a week), overweight or obese (body mass index, 25 to 40 kg/m2), and over age 65 years. The trial tested a diet-exercise intervention delivered via mailed print materials and telephone counseling. RENEW used a wait-list control, cross-over design (ie, participants received the year-long intervention immediately or after a 1-year delay), which allowed the opportunity to assess program efficacy (previously reported primary outcome), durability, and reproducibility (reported herein). Measures included diet quality (DQ), PA, BMI, and physical function (PF). Results No significant relapse was observed in the immediate-intervention arm for DQ, PA, and BMI; however, rates of functional decline increased when the intervention ceased. From year 1 to year 2, significant improvements were observed in the delayed-intervention arm; mean change scores in behaviors and BMI and PF slopes were as follows: DQ score, 5.2 (95% CI, 3.4 to 7.0); PA, 45.8 min/wk (95% CI, 26.9 to 64.6 min/wk); BMI, −0.56 (95% CI, −0.75 to −0.36); and Short Form-36 PF, −1.02 versus −5.52 (P < .001 for all measures). Overall, both arms experienced significant improvements in DQ, PA, and BMI from baseline to 2-year follow-up (P < .001). Conclusion Older cancer survivors respond favorably to lifestyle interventions and make durable changes in DQ and PA that contribute to sustained weight loss. These changes positively reorient functional decline trajectories during intervention delivery. PMID:22614994
Urbanski, Paul P.; Lenos, Aristidis; Irimie, Vadim; Bougioukakis, Petros; Zacher, Michael; Diegeler, Anno
2016-01-01
OBJECTIVES The aim of the study was to evaluate operative and long-term results after surgery of acute aortic dissection involving the root, in which the proximal repair consisted of curative resection of all dissected aortic sinuses and was performed using either valve-sparing root repair or complete root replacement with a valve conduit. METHODS Between August 2002 and March 2013, 162 consecutive patients (mean age 63 ± 14 years) underwent surgery for acute type A aortic dissection. Eighty-six patients with an involvement of the aortic root underwent curative surgery of the proximal aorta consisting of valve-sparing root repair (n = 54, 62.8%) or complete valve and root replacement using composite valve grafts (n = 32, 37.2%). In patients with root repair, all dissected aortic walls were resected and root remodelling using the single patch technique (n = 53) or root repair with valve reimplantation (n = 1) was performed without the use of any glue. All perioperative data were collected prospectively and retrospective statistical examination was performed using univariate and multivariate analyses. RESULTS The mean follow-up was 5.2 ± 3.5 years for all patients (range 0–12 years) and 6.1 ± 3.3 years for survivors. The 30-day mortality rate was 5.8% (5 patients), being considerably lower in the repair sub-cohort (1.9 vs 12.5%). The estimated survival rate at 5 and 10 years was 80.0 ± 4.5 and 69.1 ± 6.7%, respectively. No patient required reoperation on the proximal aorta and/or aortic valve during the follow-up time and there were only two valve-related events (both embolic, one in each group). Among those patients with repaired valves, the last echocardiography available showed no insufficiency in 40 and an irrelevant insufficiency (1+) in 14. CONCLUSIONS Curative repair of the proximal aorta in acute dissection involving the root provides favourable operative and long-term outcome with very low risk of aortic complications and/or reoperations, regardless if a valve-sparing procedure or replacement with a valve conduit is used. Valve-sparing surgery is frequently suitable, providing excellent outcome and very high durability. PMID:26848190
Are multiple visual short-term memory storages necessary to explain the retro-cue effect?
Makovski, Tal
2012-06-01
Recent research has shown that change detection performance is enhanced when, during the retention interval, attention is cued to the location of the upcoming test item. This retro-cue advantage has led some researchers to suggest that visual short-term memory (VSTM) is divided into a durable, limited-capacity storage and a more fragile, high-capacity storage. Consequently, performance is poor on the no-cue trials because fragile VSTM is overwritten by the test display and only durable VSTM is accessible under these conditions. In contrast, performance is improved in the retro-cue condition because attention keeps fragile VSTM accessible. The aim of the present study was to test the assumptions underlying this two-storage account. Participants were asked to encode an array of colors for a change detection task involving no-cue and retro-cue trials. A retro-cue advantage was found even when the cue was presented after a visual (Experiment 1) or a central (Experiment 2) interference. Furthermore, the magnitude of the interference was comparable between the no-cue and retro-cue trials. These data undermine the main empirical support for the two-storage account and suggest that the presence of a retro-cue benefit cannot be used to differentiate between different VSTM storages.
Activity and Durability of Iridium Nanoparticles in the Oxygen Evolution Reaction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alia, Shaun M.; Rasimick, Brian; Ngo, Chilan
Unsupported iridium (Ir) nanoparticles, that serve as standard oxygen evolution reaction (OER) catalysts in acidic electrolyzers, were investigated for electrochemical performance and durability in rotating disk electrode (RDE) half-cells. Fixed potential holds and potential cycling were applied to probe the durability of Ir nanoparticles, and performance losses were found to be driven by particle growth (coarsening) at moderate potential (1.4 to 1.6 V) and Ir dissolution at higher potential (>/=1.8 V). Several different commercially available samples were evaluated and standardized conditions for performance comparison are reported. In conclusion, the electrocatalyst RDE results have also been compared to results obtained formore » performance and durability in electrolysis cells.« less
Activity and Durability of Iridium Nanoparticles in the Oxygen Evolution Reaction
Alia, Shaun M.; Rasimick, Brian; Ngo, Chilan; ...
2016-07-15
Unsupported iridium (Ir) nanoparticles, that serve as standard oxygen evolution reaction (OER) catalysts in acidic electrolyzers, were investigated for electrochemical performance and durability in rotating disk electrode (RDE) half-cells. Fixed potential holds and potential cycling were applied to probe the durability of Ir nanoparticles, and performance losses were found to be driven by particle growth (coarsening) at moderate potential (1.4 to 1.6 V) and Ir dissolution at higher potential (>/=1.8 V). Several different commercially available samples were evaluated and standardized conditions for performance comparison are reported. In conclusion, the electrocatalyst RDE results have also been compared to results obtained formore » performance and durability in electrolysis cells.« less
Durability of certain configurations for providing skid resistance on concrete pavements.
DOT National Transportation Integrated Search
1974-01-01
The main objective of this study was to establish the factors that influence the durability of the surface configurations that are used or can be used to provide high and long lasting skid resistance for portland cement concrete pavements. In the dev...
Emerging Minimally Invasive Treatment Options for Male Lower Urinary Tract Symptoms.
Magistro, Giuseppe; Chapple, Christopher R; Elhilali, Mostafa; Gilling, Peter; McVary, Kevin T; Roehrborn, Claus G; Stief, Christian G; Woo, Henry H; Gratzke, Christian
2017-12-01
Lower urinary tract symptoms (LUTS) are one of the most common and troublesome nonmalignant conditions affecting quality of life in aging men. A spectrum of established medical and surgical options is available to provide relief of bothersome LUTS. Both the adverse events of medication and the morbidity with surgical treatment modalities have to be counterbalanced against efficacy. Novel minimally invasive treatment options aim to be effective, ideally to be performed in an ambulatory setting under local anaesthesia and to offer a more favourable safety profile than existing reference techniques. A comprehensive, narrative review of novel minimally invasive treatment modalities for the management of male LUTS due to benign prostatic enlargement is presented. Medline, PubMed, Cochrane database, and Embase were screened for randomised controlled trials (RCTs), clinical trials, and reviews on novel minimally invasive treatment options for male LUTS due to benign prostatic enlargement. With regard to newly devised intraprostatic injectables (botulinum neurotoxin A, NX1207, PRX302), PRX302 is currently the only substance that was superior to placebo in a phase 3 RCT providing proof of efficacy and safety. The prostatic urethral lift technique has been evaluated in several phase 3 trials showing rapid and durable relief of LUTS without compromising sexual function in carefully selected patients without a prominent median lobe. The first clinical experience of the temporary implantable nitinol device demonstrated that implantation of this novel device is a safe procedure, easy, and fast to perform. Further studies are required to evaluate efficacy, durability, and to define appropriate patient selection. New ablative approaches like the image guided robotic waterjet ablation (AquaBeam) or procedures based on convective water vapour energy (Rezūm) are in the early stages of development. Prostatic artery embolization performed by interventional radiologists at specialised centres shows a high technical success rate in the treatment of bothersome LUTS. However, a substantial clinical failure rate and a particular spectrum of complications not commonly seen after urologic interventions do occur and need to be critically evaluated. Initial promising clinical results on novel minimally invasive treatment options indicate efficacy comparable to standard techniques, often associated with a more favourable safety profile, in particular with preservation of sexual function. Many of these techniques are in their infancy and based on experience of new developments in the past. Further RCTs are required to evaluate efficacy, safety, and durability of novel techniques with long-term follow-up and careful evaluation of the selection criteria, which have been applied in clinical trials. The prostatic urethral lift is the only procedure with Level 1 evidence data and that can therefore be recommended for treatment of male LUTS in clinical practice for selected patients. Minimally invasive treatment options have been developed to provide relief of lower urinary tract symptoms comparable to standard surgical techniques with a more favourable safety profile. However, long-term clinical evaluation is still needed for most of these innovations before they can be recommended to be an effective replacement for standard surgical treatment. Copyright © 2017 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Advanced composites characterization with x-ray technologies
NASA Astrophysics Data System (ADS)
Baaklini, George Y.
1993-12-01
Recognizing the critical need to advance new composites for the aeronautics and aerospace industries, we are focussing on advanced test methods that are vital to successful modeling and manufacturing of future generations of high temperature and durable composite materials. These newly developed composites are necessary to reduce propulsion cost and weight, to improve performance and reliability, and to address longer-term national strategic thrusts for sustaining global preeminence in high speed air transport and in high performance military aircraft.
The long-term in vivo behavior of polymethyl methacrylate bone cement in total hip arthroplasty.
Oonishi, Hiroyuki; Akiyama, Haruhiko; Takemoto, Mitsuru; Kawai, Toshiyuki; Yamamoto, Koji; Yamamuro, Takao; Oonishi, Hironobu; Nakamura, Takashi
2011-10-01
The long-term success of cemented total hip arthroplasty (THA) has been well established. Improved outcomes, both radiographically and clinically, have resulted mainly from advances in stem design and improvements in operating techniques. However, there is concern about the durability of bone cement in vivo. We evaluated the physical and chemical properties of CMW1 bone cements retrieved from patients undergoing revision THA. CMW1 cements were retrieved from 14 patients who underwent acetabular revision because of aseptic loosening. The time in vivo before revision was 7-30 years. The bending properties of the retrieved bone cement were assessed using the three-point bending method. The molecular weight and chemical structure were analyzed by gel permeation chromatography and Fourier-transform infrared spectroscopy. The porosity of the bone cements was evaluated by 3-D microcomputer tomography. The bending strength decreased with increasing time in vivo and depended on the density of the bone cement, which we assume to be determined by the porosity. There was no correlation between molecular weight and time in vivo. The infrared spectra were similar in the retrieved cements and in the control CMW1 cements. Our results indicate that polymer chain scission and significant hydrolysis do not occur in CMW1 cement after implantation in vivo, even in the long term. CMW1 cement was stable through long-term implantation and functional loading.
Electrospun superhydrophobic membranes with unique structures for membrane distillation.
Liao, Yuan; Loh, Chun-Heng; Wang, Rong; Fane, Anthony G
2014-09-24
With modest temperature demand, low operating pressure, and high solute rejection, membrane distillation (MD) is an attractive option for desalination, waste treatment, and food and pharmaceutical processing. However, large-scale practical applications of MD are still hindered by the absence of effective membranes with high hydrophobicity, high porosity, and adequate mechanical strength, which are important properties for MD permeation fluxes, stable long-term performance, and effective packing in modules without damage. This study describes novel design strategies for highly robust superhydrophobic dual-layer membranes for MD via electrospinning. One of the newly developed membranes comprises a durable and ultrathin 3-dimensional (3D) superhydrophobic skin and porous nanofibrous support whereas another was fabricated by electrospinning 3D superhydrophobic layers on a nonwoven support. These membranes exhibit superhydrophobicity toward distilled water, salty water, oil-in-water emulsion, and beverages, which enables them to be used not only for desalination but also for other processes. The superhydrophobic dual-layer membrane #3S-N with nanofibrous support has a competitive permeation flux of 24.6 ± 1.2 kg m(-2) h(-1) in MD (feed and permeate temperate were set as 333 and 293 K, respectively) due to the higher porosity of the nanofibrous scaffold. Meanwhile, the membranes with the nonwoven support exhibit greater mechanical strength due to this support combined with better long-term performance because of the thicker 3D superhydrophobic layers. The morphology, pore size, porosity, mechanical properties, and liquid enter pressure of water of these superhydrophobic composite membranes with two different structures are reported and compared with commercial polyvinylidene fluoride membranes.
NASA Astrophysics Data System (ADS)
Lee, Tae-Hee; Park, Ka-Young; Kim, Ji-Tae; Seo, Yongho; Kim, Ki Buem; Song, Sun-Ju; Park, Byoungnam; Park, Jun-Young
2015-02-01
This study focuses on mechanisms and symptoms of several simulated failure modes, which may have significant influences on the long-term durability and operational stability of intermediate temperature-solid oxide fuel cells (IT-SOFCs), including fuel/oxidation starvation by breakdown of fuel/air supply components and wet and dry cycling atmospheres. Anode-supported IT-SOFCs consisting of a Ba0.5Sr0.5Co0.8Fe0.2O3-δ (BSCF)-Nd0.1Ce0.9O2-δ (NDC) composite cathode with an NDC electrolyte on a Ni-NDC anode substrate are fabricated via dry-pressings followed by the co-firing method. Comprehensive and systematic research based on the failure mode and effect analysis (FMEA) of anode-supported IT-SOFCs is conducted using various electrochemical and physiochemical analysis techniques to extend our understanding of the major mechanisms of performance deterioration under SOFC operating conditions. The fuel-starvation condition in the fuel-pump failure mode causes irreversible mechanical degradation of the electrolyte and cathode interface by the dimensional expansion of the anode support due to the oxidation of Ni metal to NiO. In contrast, the BSCF cathode shows poor stability under wet and dry cycling modes of cathode air due to the strong electroactivity of SrO with H2O. On the other hand, the air-depletion phenomena under air-pump failure mode results in the recovery of cell performance during the long-term operation without the visible microstructural transformation through the reduction of anode overvoltage.
Characterization of cementitiously stabilized subgrades for mechanistic-empirical pavement design
NASA Astrophysics Data System (ADS)
Solanki, Pranshoo
Pavements are vulnerable to subgrade layer performance because it acts as a foundation. Due to increase in the truck traffic, pavement engineers are challenged to build more strong and long-lasting pavements. To increase the load-bearing capacity of pavements, subgrade layer is often stabilized with cementitious additives. Thus, an overall characterization of stabilized subgrade layer is important for enhanced short- and long-term pavement performance. In this study, the effect of type and amount of additive on the short-term performance in terms of material properties recommended by the new Mechanistic-Empirical Pavement Design Guide (MEPDG) is examined. A total of four soils commonly encountered as subgrades in Oklahoma are utilized. Results show that the changes in the Mr, ME and UCS values stabilized specimens depend on the soil type and properties of additives. The long-term performance (or durability) of stabilized soil specimens is investigated by conducting freeze-thaw (F-T) cycling, vacuum saturation and tube suction tests on 7-day cured P-, K- and C-soil specimens stabilized with 6% lime, 10% CFA and 10% CKD. This study is motivated by the fact that during the service life of pavement stabilized layers are subjected to F-T cycles and moisture variations. It is found that that UCS value of all the stabilized specimens decreased with increase in the number of F-T cycles. A strong correlation was observed between UCS values retained after vacuum saturation and F-T cycles indicating that vacuum saturation could be used as a time-efficient and inexpensive method for evaluating durability of stabilized soils. In this study, short- and long-term observations from stabilization of sulfate bearing soil with locally available low (CFA), moderate (CKD) and high (lime) calcium-based stabilizers are determined to evaluate and compare the effect of additive type on the phenomenon of sulfate-induced heave. The impact of different factors on the development of the ettringite, responsible for sulfate-induced heaving, is also discussed. For Level 2 design of pavements, a total of four stress-based statistical models and two feed-forward-type artificial neural network (ANN) models, are evaluated for predicting resilient modulus of 28-day cured stabilized specimens. Specifically, one semi-log stress-based, three log-log stress-based, one Multi-Layer Perceptrons Network (MLPN), and one Radial Basis Function Network (RBFN) are developed. Overall, semi-log stress-based and MLPN neural network are found to show best acceptable performance for the present evaluation and validation datasets. Further, correlations are presented for stress-based models to correlate Mr with compacted specimen characteristics and soil/additive properties. Additionally, the effect of type of additive on indirect tensile and fatigue characteristics of selected stabilized P- and V-soil is evaluated. This study is based on the fact that stabilized layer is subjected to tensile stresses under wheel loading. Thus, the resilient modulus in tension (M rt), fatigue life and strength in tension (sigmat) or flexure (represented by modulus of rupture, MOR) becomes another important design parameter within the mechanistic framework. Cylindrical specimens are prepared, cured for 28 days and subjected to different stress sequences in indirect tension to study the Mrt. On the other hand, stabilized beam specimens are compacted using a Linear Kneading Compactor and subjected to repeated cycles of reloading-unloading after 28 days of curing in a four-point beam fatigue apparatus for evaluating fatigue life and flexural stiffness. It is found that all three additives improved the Mrt, sigmat and MOR values; however, degree of improvement varied with the type of additive and soil. This study encompasses the differences in the design of semi-rigid pavements developed using AASHTO 1993 and AASHTO 2002 MEPDG methodologies. Further, the design curves for fatigue performance prediction of stabilized layers are developed for different stabilized pavement sections. Knowledge gained from the parametric analysis of different sections using AASHTO 1993 and MEPDG is expected to be useful to pavement designers and others in implementation of the new MEPDG for future pavement design. (Abstract shortened by UMI.)
Study on basalt fiber parameters affecting fiber-reinforced mortar
NASA Astrophysics Data System (ADS)
Orlov, A. A.; Chernykh, T. N.; Sashina, A. V.; Bogusevich, D. V.
2015-01-01
This article considers the effect of different dosages and diameters of basalt fibers on tensile strength increase during bending of fiberboard-reinforced mortar samples. The optimal dosages of fiber, providing maximum strength in bending are revealed. The durability of basalt fiber in an environment of cement, by means of microscopic analysis of samples of fibers and fiberboard-reinforced mortar long-term tests is examined. The article also compares the behavior of basalt fiber in the cement stone environment to a glass one and reveals that the basalt fiber is not subject to destruction.
Cher, L; Glass, J; Harsh, G R; Hochberg, F H
1996-06-01
Disease-free survival in primary CNS lymphoma has improved with the advent of methotrexate-based pre-irradiation chemotherapy. Prolonged response durations have been noted in six of eight patients refusing radiation therapy in two of our prior series. We have treated an additional 11 patients with methotrexate-based chemotherapy without subsequent planned irradiation. Some received maintenance chemotherapy. Most have had durable responses with little or no toxicity. Prolonged responses can be maintained without radiation therapy, thus avoiding potential long-term radiation toxicity.
Revisiting the role of durable polymers in cardiovascular devices.
Mori, Hiroyoshi; Otsuka, Fumiyuki; Gupta, Anuj; Jinnouchi, Hiroyuki; Torii, Sho; Harari, Emanuel; Virmani, Renu; Finn, Aloke V
2017-11-01
Polymers are an essential component of drug-eluting stents (DES) used to control drug release but remain the most controversial component of DES technology. There are two types of polymers employed in DES: durable polymer based DES (DP-DES) and biodegradable polymer DES (BP-DES). First-generation DES were exclusively composed of DP and demonstrated increased rates of late stent failure due in part to poor polymer biocompatibility. Newer generations DES use more biocompatible durable polymers or biodegradable polymers. Areas covered: We will cover issues identified with 1st-generation DP-DES, areas of success and failure in 2nd-generation DP-DES and examine the promise and shortcomings of BP-DES. Briefly, fluorinated polymers used in 2nd-generation DP-DES have excellent anti-thrombogenicity and better biocompatibility than 1st-generation DES polymers. However, these devices lead to persistent drug exposure to the endothelium which impairs endothelial function and predisposes towards neoatherosclerosis. Meanwhile, BP-DES has shortened the duration of drug exposure which might be beneficial for endothelial functional recovery leading to less neoatherosclerosis. However, it remains uncertain whether the long-term biocompatibility of bare metal surfaces is better than that of polymer-coated metals. Expert commentary: Each technology has distinct advantages, which can be optimized depending upon the particular characteristics of the patient being treated.
Crystallization in high-level waste glass: A review of glass theory and noteworthy literature
DOE Office of Scientific and Technical Information (OSTI.GOV)
Christian, J. H.
2015-08-01
There is a fundamental need to continue research aimed at understanding nepheline and spinel crystal formation in high-level waste (HLW) glass. Specifically, the formation of nepheline solids (K/NaAlSiO₄) during slow cooling of HLW glass can reduce the chemical durability of the glass, which can cause a decrease in the overall durability of the glass waste form. The accumulation of spinel solids ((Fe, Ni, Mn, Zn)(Fe,Cr)₂O₄), while not detrimental to glass durability, can cause an array of processing problems inside of HLW glass melters. In this review, the fundamental differences between glass and solid-crystals are explained using kinetic, thermodynamic, and viscositymore » arguments, and several highlights of glass-crystallization research, as it pertains to high-level waste vitrification, are described. In terms of mitigating spinel in the melter and both spinel and nepheline formation in the canister, the complexity of HLW glass and the intricate interplay between thermal, chemical, and kinetic factors further complicates this understanding. However, new experiments seeking to elucidate the contributing factors of crystal nucleation and growth in waste glass, and the compilation of data from older experiments, may go a long way towards helping to achieve higher waste loadings while developing more efficient processing strategies.« less
Impact of future fuel properties on aircraft engines and fuel systems
NASA Technical Reports Server (NTRS)
Rudey, R. A.; Grobman, J. S.
1978-01-01
From current projections of the availability of high-quality petroleum crude oils, it is becoming increasingly apparent that the specifications for hydrocarbon jet fuels may have to be modified. The problems that are most likely to be encountered as a result of these modifications relate to engine performance, component durability and maintenance, and aircraft fuel-system performance. The effect on engine performance will be associated with changes in specific fuel consumption, ignition at relight limits, at exhaust emissions. Durability and maintenance will be affected by increases in combustor liner temperatures, carbon deposition, gum formation in fuel nozzles, and erosion and corrosion of turbine blades and vanes. Aircraft fuel-system performance will be affected by increased deposits in fuel-system heat exchangers and changes in the pumpability and flowability of the fuel. The severity of the potential problems is described in terms of the fuel characteristics most likely to change in the future. Recent data that evaluate the ability of current-technology aircraft to accept fuel specification changes are presented, and selected technological advances that can reduce the severity of the problems are described and discussed.
Pino, F; Fermo, P; La Russa, M; Ruffolo, S; Comite, V; Baghdachi, J; Pecchioni, E; Fratini, F; Cappelletti, G
2017-05-01
In the present work, two kinds of hybrid polymeric-inorganic coatings containing TiO 2 or SiO 2 particles and prepared starting from two commercial resins (Alpha®SI30 and Bluesil®BP9710) were developed and applied to two kinds of mortars (an air-hardening calcic lime mortar [ALM] and a natural hydraulic lime mortar [HLM]) to achieve better performances in terms of water repellence and consequently damage resistance. The two pure commercial resins were also applied for comparison purposes. Properties of the coated materials and their performance were studied using different techniques such as contact angle measurements, capillary absorption test, mercury intrusion porosimetry, surface free energy, colorimetric measurements and water vapour permeability tests. Tests were also performed to determine the weathering effects on both the commercial and the hybrid coatings in order to study their durability. Thus, exposures to UV radiation, to UV radiation/condensed water cycles and to a real polluted atmospheric environment have been performed. The effectiveness of the hybrid SiO 2 based coating was demonstrated, especially in the case of the HLM mortar.
Study on the durability of concrete using granulated blast furnace slag as fine aggregate
NASA Astrophysics Data System (ADS)
Shi, Dongsheng; Liu, Qiang; Xue, Xinxin; He, Peiyuan
2018-03-01
In order to assessing the durability of concrete using granulated blastfurnace slag (GBS) as fine aggregate and compare it with natural river sand concrete, three different size of specimen were produced by using the same mix proportion with 3 different water cement ratios and 3 replacement ratios, and using it to measure the three aspects on the durability of concrete including freeze-thaw performance, dry-shrinkage performance and anti-chloride-permeability performance. In this paper. The test results show that using GBS as fine aggregate can slightly improve anti-chloride-permeability performance and dry-shrinkage performance of concrete in the condition of low water cement ratio, on the other hand, using GBS or natural river sand as fine aggregate has almost similar durability of concrete.
Renal Angiomyolipoma: Mid- to Long-Term Results Following Embolization with Onyx.
Thulasidasan, Narayanan; Sriskandakumar, Srividhiya; Ilyas, Shahzad; Sabharwal, Tarun
2016-12-01
Percutaneous transcatheter embolization is currently the preferred treatment for ruptured or enlarging renal angiomyolipoma (AML), although the optimum choice of embolic material has not yet been established. We present mid- to long-term outcomes following embolization of AMLs with Onyx. Ten AMLs in seven patients (including two with tuberous sclerosis) were embolized with Onyx. Patients were followed-up clinically, with tumour size and renal function measured pre- and post-procedure. Mean pre-treatment AML size was 63.4 mm (range 42-100). Mean clinical follow-up was 431.4 days (range 153-986) and imaging follow-up 284.2 days (range 30-741). There was no haemorrhage from treated lesions within the follow-up period. Of patients who had cross-sectional imaging pre- and post-procedure, mean decrease in AML size of 22 mm was seen after Onyx embolization (p = 0.0058, 95 % CI 9.13-34.87). No significant difference between serum creatinine was seen pre- and post-procedure (p = 0.54, 95 % CI 8.63-4.85). Onyx embolization of renal AMLs is effective in the medium to long term, with theoretical benefits in safety and durability of result.
Zhang, Pinglei; Wei, Heming; Guo, Jingjing; Sun, Changsen
2016-10-01
Ground settlement (GS) is one of the causes that destroy the durability of reinforced concrete structures. It could lead to a deterioration in the structural basement and increase the risk of collapse. The methods used for GS monitoring were mostly electronic-based sensors for reading the changes in resistance, resonant frequencies, etc. These sensors often bear low accuracy in the long term. Our published work demonstrated that a fiber-optic low-coherent interferometer configured in a Michelson interferometer was designed as a GS sensor, and a micro-meter resolution in the room environment was approached. However, the designed GS sensor, which in principle is based on a hydraulic connecting vessel, has to suffer from a tilt degeneration problem due to a strictly vertical requirement in practical installment. Here, we made a design for the GS sensor based on its robust tilt performance. The experimental tests show that the sensor can work well within a ±5° tilt. This could meet the requirements in most designed GS sensor installment applications.
Lee, Chi-Yuan; Weng, Fang-Bor; Kuo, Yzu-Wei; Tsai, Chao-Hsuan; Cheng, Yen-Ting; Cheng, Chih-Kai; Lin, Jyun-Ting
2016-01-01
In the chemical reaction that proceeds in a high-temperature proton exchange membrane fuel cell stack (HT-PEMFC stack), the internal local temperature, voltage, pressure, flow and current nonuniformity may cause poor membrane material durability and nonuniform fuel distribution, thus influencing the performance and lifetime of the fuel cell stack. In this paper micro-electro-mechanical systems (MEMS) are utilized to develop a high-temperature electrochemical environment-resistant five-in-one micro-sensor embedded in the cathode channel plate of an HT-PEMFC stack, and materials and process parameters are appropriately selected to protect the micro-sensor against failure or destruction during long-term operation. In-situ measurement of the local temperature, voltage, pressure, flow and current distributions in the HT-PEMFC stack is carried out. This integrated micro-sensor has five functions, and is favorably characterized by small size, good acid resistance and temperature resistance, quick response, real-time measurement, and the goal is being able to be put in any place for measurement without affecting the performance of the battery. PMID:27763559
Lee, Chi-Yuan; Weng, Fang-Bor; Kuo, Yzu-Wei; Tsai, Chao-Hsuan; Cheng, Yen-Ting; Cheng, Chih-Kai; Lin, Jyun-Ting
2016-10-18
In the chemical reaction that proceeds in a high-temperature proton exchange membrane fuel cell stack (HT-PEMFC stack), the internal local temperature, voltage, pressure, flow and current nonuniformity may cause poor membrane material durability and nonuniform fuel distribution, thus influencing the performance and lifetime of the fuel cell stack. In this paper micro-electro-mechanical systems (MEMS) are utilized to develop a high-temperature electrochemical environment-resistant five-in-one micro-sensor embedded in the cathode channel plate of an HT-PEMFC stack, and materials and process parameters are appropriately selected to protect the micro-sensor against failure or destruction during long-term operation. In-situ measurement of the local temperature, voltage, pressure, flow and current distributions in the HT-PEMFC stack is carried out. This integrated micro-sensor has five functions, and is favorably characterized by small size, good acid resistance and temperature resistance, quick response, real-time measurement, and the goal is being able to be put in any place for measurement without affecting the performance of the battery.
Ghadge, Shrinath Dattatray; Patel, Prasad Prakash; Datta, Moni Kanchan; ...
2017-03-20
Identification and development of high performance with reduced overpotential (i.e. reduced operating electricity cost) oxygen evolution reaction (OER) electrocatalysts for proton exchange membrane (PEM) based water electrolysis with ultra-low noble metal content (i.e. reduced materials cost) is of significant interest for economic hydrogen production, thus increasing the commercialization potential of PEM water electrolysis. Accordingly, a novel electrocatalyst should exhibit low overpotential, excellent electrochemical activity and durability superior to state of the art noble metal based electro-catalysts (e.g. Pt, IrO 2, RuO 2). Here in this paper, for the very first time to the best of our knowledge, exploiting first-principles theoreticalmore » calculations of the total energies and electronic structures, we have identified a reduced noble metal content fluorine doped solid solution of MnO 2 and IrO 2, denoted as (Mn 1-xIr x)O 2:F (x = 0.2, 0.3, 0.4), OER electrocatalyst system exhibiting lower overpotential and higher current density than the state of the art IrO 2 and other previously reported systems for PEM water electrolysis. The doped solid solution displays an excellent electrochemical performance with a lowest reported onset potential to date of ~1.35 V (vs. RHE), ~80 mV lower than that of IrO 2 (~1.43 V vs. RHE) and ~15 fold (x = 0.3 and 0.4) higher electrochemical activity compared to pure IrO 2. In addition, the system displays excellent long term electrochemical durability, similar to that of IrO 2 in harsh acidic OER operating conditions. Our study therefore demonstrates remarkable, ~60–80% reduction in noble metal content along with lower overpotential and excellent electrochemical performance clearly demonstrating the potential of the (Mn 1-xIr x)O 2:F system as an OER electro-catalyst for PEM water electrolysis.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghadge, Shrinath Dattatray; Patel, Prasad Prakash; Datta, Moni Kanchan
Identification and development of high performance with reduced overpotential (i.e. reduced operating electricity cost) oxygen evolution reaction (OER) electrocatalysts for proton exchange membrane (PEM) based water electrolysis with ultra-low noble metal content (i.e. reduced materials cost) is of significant interest for economic hydrogen production, thus increasing the commercialization potential of PEM water electrolysis. Accordingly, a novel electrocatalyst should exhibit low overpotential, excellent electrochemical activity and durability superior to state of the art noble metal based electro-catalysts (e.g. Pt, IrO 2, RuO 2). Here in this paper, for the very first time to the best of our knowledge, exploiting first-principles theoreticalmore » calculations of the total energies and electronic structures, we have identified a reduced noble metal content fluorine doped solid solution of MnO 2 and IrO 2, denoted as (Mn 1-xIr x)O 2:F (x = 0.2, 0.3, 0.4), OER electrocatalyst system exhibiting lower overpotential and higher current density than the state of the art IrO 2 and other previously reported systems for PEM water electrolysis. The doped solid solution displays an excellent electrochemical performance with a lowest reported onset potential to date of ~1.35 V (vs. RHE), ~80 mV lower than that of IrO 2 (~1.43 V vs. RHE) and ~15 fold (x = 0.3 and 0.4) higher electrochemical activity compared to pure IrO 2. In addition, the system displays excellent long term electrochemical durability, similar to that of IrO 2 in harsh acidic OER operating conditions. Our study therefore demonstrates remarkable, ~60–80% reduction in noble metal content along with lower overpotential and excellent electrochemical performance clearly demonstrating the potential of the (Mn 1-xIr x)O 2:F system as an OER electro-catalyst for PEM water electrolysis.« less
Stanger, Olaf; Bleuel, Irina; Gisler, Fabian; Göber, Volkhard; Reineke, Sylvia; Gahl, Brigitta; Aymard, Thierry; Englberger, Lars; Carrel, Thierry; Tevaearai, Hendrik
2015-07-01
To report our institutional experience and long-term results with the Freedom Solo bovine pericardial stentless bioprosthesis (Sorin Group, Saluggia, Italy). Between January 2005 and November 2009, 149 patients (mean age, 73.6 ± 8.7 years; 68 [45.6%] female) underwent isolated (n = 75) or combined (n = 74) aortic valve replacement (AVR) using the Solo in our institution. Follow-up was 100% complete with an average follow-up time of 5.9 ± 2.6 years (maximum, 9.6 years) and a total of 885.3 patient years. Operative (30-day) mortality was 2.7% (1.3% for isolated AVR [n = 1] and 4.0% for combined procedures [n = 3]). All causes of death were not valve-related. Preoperative peak (mean) gradients of 74.2 ± 23.0 mm Hg (48.6 ± 16.3 mm Hg) decreased to 15.6 ± 5.4 mm Hg (8.8 ± 3.0 mm Hg) after AVR, and remained low for up to 9 years. The postoperative effective orifice area was 1.6 ± 0.57 cm(2), 1.90 ± 0.45 cm(2), 2.12 ± 0.48 cm(2), and 2.20 ± 0.66 cm(2) for the valve sizes 21, 23, 25, and 27, respectively, with absence of severe prosthesis-patient mismatch and 0.7% (n = 1) experienced moderate prosthesis-patient mismatch. During follow-up, 26 patients experienced structural valve deterioration (SVD) and 14 patients underwent explantation. Kaplan-Meier estimates for freedom from death, explantation, and SVD at 9 years averaged 0.57 (range, 0.47-0.66), 0.82 (range, 0.69-0.90), and 0.70 (range, 0.57-0.79), respectively. The Freedom Solo stentless aortic valve is safe to implant and shows excellent early and midterm hemodynamic performance. However, SVD was observed in a substantial number of patients after only 5-6 years and the need for explantation increased markedly, suggesting low durability. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Development of a Prototype Water Pump for Future Space Suit Applications
NASA Technical Reports Server (NTRS)
Hartman, David; Hodgson, Edward; Dionne, Steven; Gervais, Edward, III; Trevino, Luis
2009-01-01
NASA's next generation of space suit systems will place new demands on the pump used to circulate cooling water through the life support system and the crew's liquid cooling garment. Long duration missions and frequent EVA require increased durability and reliability; limited resupply mass requirements demand compatibility with recycled water, and changing system design concepts demand increased tolerance for dissolved and free gas and the ability to operate over a broader range of flow rates and discharge pressure conditions. This paper describes the development of a positive displacement prototype pump to meet these needs. A gerotor based design has been adapted to meet pump performance, gas tolerance, and durability requirements while providing a small, lightweight pump assembly. This design has been detailed and implemented using materials selected to address anticipated water quality and mission needs as a prototype unit for testing in NASA laboratories. Design requirements, pump technology selection and design, performance testing and test results will be discussed.
Development of a Prototype Water Pump for Future Space Suit Applications
NASA Technical Reports Server (NTRS)
Hartman, David; Hodgson, Edward; Gervais, Edward, III; Trevino, Luis
2008-01-01
NASA s next generation of space suit systems will place new demands on the pump used to circulate cooling water through the life support system and the crew s liquid cooling garment. Long duration missions and frequent EVA require increased durability and reliability; limited resupply mass requirements demand compatibility with recycled water, and changing system design concepts demand increased tolerance for dissolved and free gas and the ability to operate over a broader range of flow rates and discharge pressure conditions. This paper describes the development of a positive displacement prototype pump to meet these needs. A gerotor based design has been adapted to meet pump performance, gas tolerance, and durability requirements while providing a small, lightweight pump assembly. This design has been detailed and implemented using materials selected to address anticipated water quality and mission needs as a prototype unit for testing in NASA laboratories. Design requirements, pump technology selection and design, performance testing and test results will be discussed.
Thin co-radial bipolar leads: technology and clinical performance.
Fahraeus, T; Israel, C W; Wöllenstein, M
2001-09-01
While bipolar leads offer advantages such as better sensing performance than unipolar leads, their use has been limited by a larger lead diameter and reports about a high failure rate of several bipolar lead models. This has led to the development of thin bipolar leads using a special technology which aims at improving lead safety. Leads with monofilar thin conductors (drawn filled tube) which are individually coated with a very resistant material (ETFE) have been developed. Using a co-radial instead of co-axial bipolar conductor design, the lead diameter could be reduced to 4.5 F compared to 6-7 F of conventional bipolar leads. Bench testing demonstrated a significant improvement of this lead technology with respect to degradation of insulation material by biochemically reactive solutions. Also mechanical characteristics such as resistance to tearing forces and compression showed a high lead durability. From our own experience, co-radial bipolar leads show a favorable electrical performance with the exception of a relatively low pacing impedance. Also during long-term follow-up, the rate of lead failure was very low. These findings are corroborated by other clinical studies which also demonstrated good handling characteristics of thin bipolar leads during implantation.
Bella, Federico; Popovic, Jelena; Lamberti, Andrea; Tresso, Elena; Gerbaldi, Claudio; Maier, Joachim
2017-11-01
With the purpose of achieving stable dye-sensitized solar cells (DSSCs) with high efficiency, a new type of soft matter electrolyte is tested in which specific amounts of nanosized silica particles are finely dispersed in short-chained polyethylene glycol dimethylether encompassing an iodide/triiodide redox mediator. This results in a solid-liquid composite having synergistic electrical and favorable mechanical properties. The combination of interfacial effects and particle network formation promotes enhanced ion transport, which directly impacts the short-circuit photocurrent density. Thorough analysis reveals that this newly elaborated class of electrolytes is able to improve, at the same time, the thermal and long-term stability of DSSCs, as well as power conversion efficiency under standard and lower irradiation intensities. Lab-scale devices with champion efficiency exceeding 11% under attenuated sunlight (20 mW cm -2 , with a compact TiO 2 blocking layer) are obtained, along with impressively stable performance under both thermal stress and light soaking in an indoor environment (>96% performance retention after 2500 h of accelerated aging under full sun alternated with thermal ramps), matching the durability criteria applied to silicon solar cells for outdoor applications. The new findings might foster widespread practical application of DSSCs.
Highly efficient and durable TiN nanofiber electrocatalyst supports.
Kim, Hyun; Cho, Min Kyung; Kwon, Jeong An; Jeong, Yeon Hun; Lee, Kyung Jin; Kim, Na Young; Kim, Min Jung; Yoo, Sung Jong; Jang, Jong Hyun; Kim, Hyoung-Juhn; Nam, Suk Woo; Lim, Dong-Hee; Cho, EunAe; Lee, Kwan-Young; Kim, Jin Young
2015-11-28
To date, carbon-based materials including various carbon nanostructured materials have been extensively used as an electrocatalyst support for proton exchange membrane fuel cell (PEMFC) applications due to their practical nature. However, carbon dissolution or corrosion caused by high electrode potential in the presence of O2 and/or water has been identified as one of the main failure modes for the device operation. Here, we report the first TiN nanofiber (TNF)-based nonwoven structured materials to be constructed via electrospinning and subsequent two-step thermal treatment processes as a support for the PEMFC catalyst. Pt catalyst nanoparticles (NPs) deposited on the TNFs (Pt/TNFs) were electrochemically characterized with respect to oxygen reduction reaction (ORR) activity and durability in an acidic medium. From the electrochemical tests, the TNF-supported Pt catalyst was better and more stable in terms of its catalytic performance compared to a commercially available carbon-supported Pt catalyst. For example, the initial oxygen reduction performance was comparable for both cases, while the Pt/TNF showed much higher durability from an accelerated degradation test (ADT) configuration. It is understood that the improved catalytic roles of TNFs on the supported Pt NPs for ORR are due to the high electrical conductivity arising from the extended connectivity, high inertness to the electrochemical environment and strong catalyst-support interactions.
Self-Healing Superhydrophobic Materials Showing Quick Damage Recovery and Long-Term Durability.
Wang, Liming; Urata, Chihiro; Sato, Tomoya; England, Matt W; Hozumi, Atsushi
2017-09-26
Superhydrophobic coatings/materials are important for a wide variety of applications, but the majority of these man-made coatings/materials still suffer from poor durability because of their lack of self-healing ability. Here, we report novel superhydrophobic materials which can quickly self-heal from various severe types of damage. In this study, we used poly(dimethylsiloxane) (PDMS) infused with two liquids: trichloropropylsilane, which reacts with ambient moisture to self-assemble into grass-like microfibers (named silicone micro/nanograss) on the surfaces and low-viscosity silicone oil (SO), which remains within the PDMS matrices and acts as a self-healing agent. Because of the silicone micro/nanograss structures on the PDMS surfaces and the effective preserve/protection system of a large quantity of SO within the PDMS matrices, our superhydrophobic materials showed quick superhydrophobic recovery under ambient conditions (within 1-2 h) even after exposure to plasma (24 h), boiling water, chemicals, and outside environments. Such an ability is superior to the best self-healing superhydrophobic coatings/materials reported so far.
Overview of existing cartilage repair technology.
McNickle, Allison G; Provencher, Matthew T; Cole, Brian J
2008-12-01
Currently, autologous chondrocyte implantation and osteochondral grafting bridge the gap between palliation of cartilage injury and resurfacing via arthroplasty. Emerging technologies seek to advance first generation techniques and accomplish several goals including predictable outcomes, cost-effective technology, single-stage procedures, and creation of durable repair tissue. The biologic pipeline represents a variety of technologies including synthetics, scaffolds, cell therapy, and cell-infused matrices. Synthetic constructs, an alternative to biologic repair, resurface a focal chondral defect rather than the entire joint surface. Scaffolds are cell-free constructs designed as a biologic "net" to augment marrow stimulation techniques. Minced cartilage technology uses stabilized autologous or allogeneic fragments in 1-stage transplantation. Second and third generation cell-based methods include alternative membranes, chondrocyte seeding, and culturing onto scaffolds. Despite the promising early results of these products, significant technical obstacles remain along with unknown long-term durability. The vast array of developing technologies has exceptional promise and the potential to revolutionize the cartilage treatment algorithm within the next decade.
From coagulation to enucleation: the use of lasers in surgery for benign prostatic hyperplasia.
Wilson, Liam C; Gilling, Peter J
2005-09-01
The application of lasers for the treatment of benign prostatic hyperplasia has evolved over the past 15 years. Early-generation neodymium:yttrium aluminum garnet lasers were used to coagulate and ablate prostatic tissue, but significant postoperative irritative symptoms and high reoperation rates meant that this approach did not seriously challenge the status quo for long. Ablative techniques have recently become popular again with the marketing of the newer-generation, higher-power potassium titanyl phosphate and holmium lasers. Although short-term data are encouraging, there are no comparative trials of significant duration, so it is not yet possible to draw conclusions with regard to efficacy and durability. The holmium laser can also be used as an incisional and dissecting tool that allows resection or enucleation of whole lobes of the prostate, mimicking the action of the index finger in open prostatectomy. The safety, efficacy, durability and cost-effectiveness of the holmium laser have been shown in well-designed randomized controlled trials.
One-volt-driven superfast polymer actuators based on single-ion conductors
Kim, Onnuri; Kim, Hoon; Choi, U. Hyeok; Park, Moon Jeong
2016-01-01
The key challenges in the advancement of actuator technologies related to artificial muscles include fast-response time, low operation voltages and durability. Although several researchers have tackled these challenges over the last few decades, no breakthrough has been made. Here we describe a platform for the development of soft actuators that moves a few millimetres under 1 V in air, with a superfast response time of tens of milliseconds. An essential component of this actuator is the single-ion-conducting polymers that contain well-defined ionic domains through the introduction of zwitterions; this achieved an exceptionally high dielectric constant of 76 and a 300-fold enhancement in ionic conductivity. Moreover, the actuator demonstrated long-term durability, with negligible changes in the actuator stroke over 20,000 cycles in air. Owing to its low-power consumption (only 4 mW), we believe that this actuator could pave the way for cutting-edge biomimetic technologies in the future. PMID:27857067
Wilkins, Nicolas J; Rawson, Katherine A
2013-10-01
In Rickard, Lau, and Pashler's (2008) investigation of the lag effect on memory-based automaticity, response times were faster and proportion of trials retrieved was higher at the end of practice for short lag items than for long lag items. However, during testing after a delay, response times were slower and proportion of trials retrieved was lower for short lag items than for long lag items. The current study investigated the extent to which the lag effect on the durability of memory-based automaticity is due to interference or to the loss of memory strength with time. Participants repeatedly practiced alphabet subtraction items in short lag and long lag conditions. After practice, half of the participants were immediately tested and the other half were tested after a 7-day delay. Results indicate that the lag effect on the durability of memory-based automaticity is primarily due to interference. We discuss potential modification of current memory-based processing theories to account for these effects. © 2013.
Long-Term Outcome of Gamma Knife Radiosurgery for Treatment of Typical Trigeminal Neuralgia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Han, Jung Ho; Kim, Dong Gyu, E-mail: gknife@plaza.snu.ac.k; Chung, Hyun-Tai
2009-11-01
Purpose: To analyze the long-term outcomes of patients with typical trigeminal neuralgia treated with gamma knife radiosurgery (GKRS). Patients and Methods: A total of 62 consecutive patients with typical trigeminal neuralgia were treated with GKRS between 1998 and 2004. Of the 62 patients, 2 were lost to follow-up; the remaining 60 patients were followed for >12 months. The mean prescribed maximal dose was 79.7 Gy (range, 75-80), using a 4-mm shot. Results: Of the 60 patients, 48 were followed for >4 years. An additional 3 patients, followed for <4 years, experienced recurrent pain after a favorable initial response and weremore » incorporated into the long-term response analysis. Of these 51 patients (mean age, 61 +- 11 years; 37 women [72.5%]; and mean follow-up duration, 58 +- 14 months), 46 (90.2%) responded to GKRS, as demonstrated by an improvement in their Barrow Neurological Institute pain intensity score. Of the 46 patients, 24 (52.2%) had pain recurrence. The actuarial recurrence-free survival rate was 84.8%, 76.1%, 69.6%, 63.0%, and 45.8% at 1, 2, 3, 4, and 5 years after radiosurgery, respectively. Patient age >70 years correlated with a favorable outcome in terms of pain recurrence after radiosurgery (hazard ratio, 0.125; 95% confidence interval, 0.016-0.975; p = .047) on multivariate analysis. Conclusion: GKRS seems to be an effective treatment modality for patients with typical trigeminal neuralgia considering the initial response rate; however, fewer than one-half of patients might continue to benefit from GKRS after long-term follow-up. Elderly patients might be good candidates for radiosurgery considering the long-term durability of efficacy.« less
Interactions between liquid-water and gas-diffusion layers in polymer-electrolyte fuel cells
Das, Prodip K.; Santamaria, Anthony D.; Weber, Adam Z.
2015-06-11
Over the past few decades, a significant amount of research on polymer-electrolyte fuel cells (PEFCs) has been conducted to improve performance and durability while reducing the cost of fuel cell systems. However, the cost associated with the platinum (Pt) catalyst remains a barrier to their commercialization and PEFC durability standards have yet to be established. An effective path toward reducing PEFC cost is making the catalyst layers (CLs) thinner thus reducing expensive Pt content. The limit of thin CLs is high gas-transport resistance and the performance of these CLs is sensitive to the operating temperature due to their inherent lowmore » water uptake capacity, which results in higher sensitivity to liquid-water flooding and reduced durability. Therefore, reducing PEFC's cost by decreasing Pt content and improving PEFC's performance and durability by managing liquid-water are still challenging and open topics of research. An overlooked aspect nowadays of PEFC water management is the gas-diffusion layer (GDL). While it is known that GDL's properties can impact performance, typically it is not seen as a critical component. In this work, we present data showing the importance of GDLs in terms of water removal and management while also exploring the interactions between liquid-water and GDL surfaces. The critical interface of GDL and gas-flow-channel in the presence of liquid-water was examined through systematic studies of adhesion forces as a function of water-injection rate for various GDLs of varying thickness. GDL properties (breakthrough pressure and adhesion force) were measured experimentally under a host of test conditions. Specifically, the effects of GDL hydrophobic (PTFE) content, thickness, and water-injection rate were examined to identify trends that may be beneficial to the design of liquid-water management strategies and next-generation GDL materials for PEFCs.« less