Sample records for performance measures standards

  1. A National Initiative to Advance School Mental Health Performance Measurement in the US

    ERIC Educational Resources Information Center

    Connors, Elizabeth Halsted; Stephan, Sharon Hoover; Lever, Nancy; Ereshefsky, Sabrina; Mosby, Amanda; Bohnenkamp, Jill

    2016-01-01

    Standardized health performance measurement has increasingly become an imperative for assuring quality standards in national health care systems. As compared to somatic health performance measures, behavioral health performance measures are less developed. There currently is no national standardized performance measurement system for monitoring…

  2. Performance measures for lower gastrointestinal endoscopy: a European Society of Gastrointestinal Endoscopy (ESGE) quality improvement initiative

    PubMed Central

    Thomas-Gibson, Siwan; Bugajski, Marek; Bretthauer, Michael; Rees, Colin J; Dekker, Evelien; Hoff, Geir; Jover, Rodrigo; Suchanek, Stepan; Ferlitsch, Monika; Anderson, John; Roesch, Thomas; Hultcranz, Rolf; Racz, Istvan; Kuipers, Ernst J; Garborg, Kjetil; East, James E; Rupinski, Maciej; Seip, Birgitte; Bennett, Cathy; Senore, Carlo; Minozzi, Silvia; Bisschops, Raf; Domagk, Dirk; Valori, Roland; Spada, Cristiano; Hassan, Cesare; Dinis-Ribeiro, Mario; Rutter, Matthew D

    2017-01-01

    The European Society of Gastrointestinal Endoscopy and United European Gastroenterology present a short list of key performance measures for lower gastrointestinal endoscopy. We recommend that endoscopy services across Europe adopt the following seven key performance measures for lower gastrointestinal endoscopy for measurement and evaluation in daily practice at a center and endoscopist level: 1 rate of adequate bowel preparation (minimum standard 90%); 2 cecal intubation rate (minimum standard 90%); 3 adenoma detection rate (minimum standard 25%); 4 appropriate polypectomy technique (minimum standard 80%); 5 complication rate (minimum standard not set); 6 patient experience (minimum standard not set); 7 appropriate post-polypectomy surveillance recommendations (minimum standard not set). Other identified performance measures have been listed as less relevant based on an assessment of their importance, scientific acceptability, feasibility, usability, and comparison to competing measures. PMID:28507745

  3. Standard & Poor's "Return on Resources" Measure of School Performance. Issue Brief. Volume 1, Issue 1

    ERIC Educational Resources Information Center

    Reeder, Brian

    2004-01-01

    Standard & Poors (S&P) uses a measure they call a Performance Cost Index (PCI) as their measure of a school or district?s ?Return on Resources?. The Performance Cost Index is defined as the average cost per measured ?unit? of student performance. In its simplest form, the Performance Cost Index is calculated as per student expenditures divided by…

  4. Measuring relative performance of an EDS detector using a NiO standard.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sugar, Joshua Daniel; Kotula, Paul Gabriel

    2013-09-01

    A method for measuring the relative performance of energy dispersive spectrometers (EDS) on a TEM is discussed. A NiO thin-film standard fabricated at Sandia CA is used. A performance parameter,, is measured and compared to values on several TEM systems.

  5. 34 CFR 403.201 - What are the State's responsibilities for developing and implementing a statewide system of core...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and implementing a statewide system of core standards and measures of performance? 403.201 Section 403... a statewide system of core standards and measures of performance? (a)(1) Each State board receiving funds under the Act shall develop and implement a statewide system of core standards and measures of...

  6. Intelligence Level Performance Standards Research for Autonomous Vehicles

    PubMed Central

    Bostelman, Roger B.; Hong, Tsai H.; Messina, Elena

    2017-01-01

    United States and European safety standards have evolved to protect workers near Automatic Guided Vehicles (AGV’s). However, performance standards for AGV’s and mobile robots have only recently begun development. Lessons can be learned from research and standards efforts for mobile robots applied to emergency response and military applications. Research challenges, tests and evaluations, and programs to develop higher intelligence levels for vehicles can also used to guide industrial AGV developments towards more adaptable and intelligent systems. These other efforts also provide useful standards development criteria for AGV performance test methods. Current standards areas being considered for AGVs are for docking, navigation, obstacle avoidance, and the ground truth systems that measure performance. This paper provides a look to the future with standards developments in both the performance of vehicles and the dynamic perception systems that measure intelligent vehicle performance. PMID:28649189

  7. Intelligence Level Performance Standards Research for Autonomous Vehicles.

    PubMed

    Bostelman, Roger B; Hong, Tsai H; Messina, Elena

    2015-01-01

    United States and European safety standards have evolved to protect workers near Automatic Guided Vehicles (AGV's). However, performance standards for AGV's and mobile robots have only recently begun development. Lessons can be learned from research and standards efforts for mobile robots applied to emergency response and military applications. Research challenges, tests and evaluations, and programs to develop higher intelligence levels for vehicles can also used to guide industrial AGV developments towards more adaptable and intelligent systems. These other efforts also provide useful standards development criteria for AGV performance test methods. Current standards areas being considered for AGVs are for docking, navigation, obstacle avoidance, and the ground truth systems that measure performance. This paper provides a look to the future with standards developments in both the performance of vehicles and the dynamic perception systems that measure intelligent vehicle performance.

  8. Recommendations for the performance rating of flat plate terrestrial photovoltaic solar panels

    NASA Technical Reports Server (NTRS)

    Treble, F. C.

    1976-01-01

    A review of recommendations for standardizing the performance rating of flat plate terrestrial solar panels is given to develop an international standard code of practice for performance rating. Required data to characterize the performance of a solar panel are listed. Other items discussed are: (1) basic measurement procedures; (2) performance measurement in natural sunlight and simulated sunlight; (3) standard solar cells; (4) the normal incidence method; (5) global method and (6) definition of peak power.

  9. Overall ED efficiency is associated with decreased time to percutaneous coronary intervention for ST-segment elevation myocardial infarction.

    PubMed

    Jones, Christopher W; Sonnad, Seema S; Augustine, James J; Reese, Charles L

    2014-10-01

    Performance of percutaneous coronary intervention (PCI) within 90 minutes of hospital arrival for ST-segment elevation myocardial infarction patients is a commonly cited clinical quality measure. The Centers for Medicare and Medicaid Services use this measure to adjust hospital reimbursement via the Value-Based Purchasing Program. This study investigated the relationship between hospital performance on this quality measure and emergency department (ED) operational efficiency. Hospital-level data from Centers for Medicare and Medicaid Services on PCI quality measure performance was linked to information on operational performance from 272 US EDs obtained from the Emergency Department Benchmarking Alliance annual operations survey. Standard metrics of ED size, acuity, and efficiency were compared across hospitals grouped by performance on the door-to-balloon time quality measure. Mean hospital performance on the 90-minute arrival to PCI measure was 94.0% (range, 42-100). Among hospitals failing to achieve the door-to-balloon time performance standard, median ED length of stay was 209 minutes, compared with 173 minutes among those hospitals meeting the benchmark standard (P < .001). Similarly, median time from ED patient arrival to physician evaluation was 39 minutes for hospitals below the performance standard and 23 minutes for hospitals at the benchmark standard (P < .001). Markers of ED size and acuity, including annual patient volume, admission rate, and the percentage of patients arriving via ambulance did not vary with door-to-balloon time. Better performance on measures associated with ED efficiency is associated with more timely PCI performance. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. International Comparison Test in Asia-Pacific Region for Impulse Voltage Measurements

    NASA Astrophysics Data System (ADS)

    Wakimoto, Takayuki; Ishii, Masaru; Goshima, Hisashi; Hino, Etsuhiro; Shimizu, Hiroyuki; Li, Yi; Ik-Soo, Kim

    The national standard class divider for the lightning impulse voltage measurements in Japan was developed in 1998. After three years, the standard impulse voltage calibrator was manufactured, too. These standard equipment are used as an industrial standard, and the performance had been evaluated annually supported by Ministry of Economy, Trade and Industry (METI). The standard impulse measuring system including the standard divider participated in the worldwide comparison test and its good performance was confirmed in 1999. Another international comparison test was carried out among three countries in the Asia-Pacific region in 2004 again and the standard measuring system participated in the test. In this paper, the details and the results of the international comparison tests in 2004 are described.

  11. Performance measurement for case management: principles and objectives for developing standard measures.

    PubMed

    Howe, Rufus

    2005-01-01

    Developing standardized performance measurements for case management (CM) has become the holy grail of the field. The Council for Case Management Accountability (CCMA), a leadership committee of the Case Management Society of America (CMSA), has been grappling with the concept since early 2003. This article lays out a theoretical framework for performance measurement and then outlines the progress on a specific initiative begun by CCMA to correlate CM practices with improved outcome measures.

  12. Performance testing of radiobioassay laboratories: In vivo measurements, Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacLellan, J.A.; Traub, R.J.; Olsen, P.C.

    1990-04-01

    A study of two rounds of in vivo laboratory performance testing was undertaken by Pacific Northwest Laboratory (PNL) to determine the appropriateness of the in vivo performance criteria of draft American National Standards Institute (ANSI) standard ANSI N13.3, Performance Criteria for Bioassay.'' The draft standard provides guidance to in vivo counting facilities regarding the sensitivity, precision, and accuracy of measurements for certain categories of commonly assayed radionuclides and critical regions of the body. This report concludes the testing program by presenting the results of the Round Two testing. Testing involved two types of measurements: chest counting for radionuclide detection inmore » the lung, and whole body counting for detection of uniformly distributed material. Each type of measurement was further divided into radionuclide categories as defined in the draft standard. The appropriateness of the draft standard criteria by measuring a laboratory's ability to attain them were judged by the results of both round One and Round Two testing. The testing determined that performance criteria are set at attainable levels, and the majority of in vivo monitoring facilities passed the criteria when complete results were submitted. 18 refs., 18 figs., 15 tabs.« less

  13. What should DOE do to help establish voluntary consensus standards for measuring and rating the performance of PV modules?

    NASA Technical Reports Server (NTRS)

    Runkle, L. D.

    1984-01-01

    In response to concern expressed by the photovoltaics community over progress toward the establishment and issuance of concensus standards on photovoltaic performance measurements, a review of the status of and progress in developing these standards was conducted. It examined the roles of manufacturers, and consumers and the national laboratories funded by the U.S. Department of Energy (DOE) in supporting this effort. This was done by means of a series of discussions with knowledgeable members of the photovoltaic community. Results of these interviews are summarized and a new approach to managing support of standards activity is recommended that responds to specific problems found in the performance measurement standards area. The study concludes that there is a positive role to be played by the U.S. Department of Energy in establishing collector performance measurement standards. It recommends that DOE continue to provide direct financial support for selected committees and for research at national laboratories, and that management of the activity be restructured to increase the authority and responsibility of the consensus committees.

  14. Written Expression Performance in Adolescents with Attention-Deficit/Hyperactivity Disorder (ADHD)

    ERIC Educational Resources Information Center

    DeBono, Tony; Hosseini, Armita; Cairo, Cassandra; Ghelani, Karen; Tannock, Rosemary; Toplak, Maggie E.

    2012-01-01

    We examined written expression performance in a sample of adolescents with ADHD and subthreshold ADHD using two different strategies: examining performance on standardized measures of written expression and using other indicators of written expression developed in this study. We examined associations between standardized measures of written…

  15. A new technique for measuring listening and reading literacy in developing countries

    NASA Astrophysics Data System (ADS)

    Greene, Barbara A.; Royer, James M.; Anzalone, Stephen

    1990-03-01

    One problem in evaluating educational interventions in developing countries is the absence of tests that adequately reflect the culture and curriculum. The Sentence Verification Technique is a new procedure for measuring reading and listening comprehension that allows for the development of tests based on materials indigenous to a given culture. The validity of using the Sentence Verification Technique to measure reading comprehension in Grenada was evaluated in the present study. The study involved 786 students at standards 3, 4 and 5. The tests for each standard consisted of passages that varied in difficulty. The students identified as high ability students in all three standards performed better than those identified as low ability. All students performed better with easier passages. Additionally, students in higher standards performed bettter than students in lower standards on a given passage. These results supported the claim that the Sentence Verification Technique is a valid measure of reading comprehension in Grenada.

  16. Unobtrusive measurement of indoor energy expenditure using an infrared sensor-based activity monitoring system.

    PubMed

    Hwang, Bosun; Han, Jonghee; Choi, Jong Min; Park, Kwang Suk

    2008-11-01

    The purpose of this study was to develop an unobtrusive energy expenditure (EE) measurement system using an infrared (IR) sensor-based activity monitoring system to measure indoor activities and to estimate individual quantitative EE. IR-sensor activation counts were measured with a Bluetooth-based monitoring system and the standard EE was calculated using an established regression equation. Ten male subjects participated in the experiment and three different EE measurement systems (gas analyzer, accelerometer, IR sensor) were used simultaneously in order to determine the regression equation and evaluate the performance. As a standard measurement, oxygen consumption was simultaneously measured by a portable metabolic system (Metamax 3X, Cortex, Germany). A single room experiment was performed to develop a regression model of the standard EE measurement from the proposed IR sensor-based measurement system. In addition, correlation and regression analyses were done to compare the performance of the IR system with that of the Actigraph system. We determined that our proposed IR-based EE measurement system shows a similar correlation to the Actigraph system with the standard measurement system.

  17. Best practices in selecting performance measures and standards for effective asset management.

    DOT National Transportation Integrated Search

    2011-06-01

    "This report assesses and provides guidance on best practices in performance measurement, management and standards : setting for effective Transportation Asset Management (TAM). The study is conducted through a literature review, a : survey of the 50...

  18. Effect of calendar age on physical performance: A comparison of standard clinical measures with instrumented measures in middle-aged to older adults.

    PubMed

    Stijntjes, M; Meskers, C G M; de Craen, A J M; van Lummel, R C; Rispens, S M; Slagboom, P E; Maier, A B

    2016-03-01

    Decline in physical performance is highly prevalent during aging. Identification of sensitive markers of age-related changes in physical performance is important for early detection, development of therapeutic strategies and insight into underlying mechanisms. We studied the association of calendar age and familial longevity with standard clinical and instrumented measures of physical performance in a cohort of healthy middle-aged to older adults. Cross-sectional analysis within the Leiden Longevity Study consisting of offspring of nonagenarian siblings and their partners (n=300, mean age (SD) 65.3 (6.7) years). Standard clinical measures were 25-meter walking speed and total duration of the chair stand test (CST). Instrumented measures were determined using a body fixed sensor. Dependence of physical performance on calendar age and familial longevity (offspring versus partner status) was analyzed using linear and logistic regression, respectively, adjusted for gender and height. Higher calendar age was associated with slower walking speed and longer duration of the CST (standardized β (95% CI) -.024 (-.042; -.006) and .035 (.014;.056), respectively). Instrumented measures showed similar effect sizes with strongest associations for gait stability and symmetry in mediolateral direction and for the extension and flexion phase of sit-to-stand and stand-to-sit transfers, respectively. No differences were observed between offspring of nonagenarian siblings and their partners. Standard clinical and instrumented measures of physical performance are associated with similar effect size to age-related changes in physical performance observable from middle age. The potential added value of instrumented measures for understanding underlying mechanisms requires further attention. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. 34 CFR 400.7 - What are the provisions governing the issuance of State core standards and measures of...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... core standards and measures of performance and State rules or regulations? 400.7 Section 400.7... PROVISIONS § 400.7 What are the provisions governing the issuance of State core standards and measures of... draft proposal that the State board develops for a statewide system of core standards and measures of...

  20. 20 CFR 638.302 - Performance measurement.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Performance measurement. 638.302 Section 638... § 638.302 Performance measurement. The Job Corps Director shall establish a national performance measurement system for centers and other program components which shall include annual performance standards...

  1. 20 CFR 638.302 - Performance measurement.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 20 Employees' Benefits 3 2012-04-01 2012-04-01 false Performance measurement. 638.302 Section 638... § 638.302 Performance measurement. The Job Corps Director shall establish a national performance measurement system for centers and other program components which shall include annual performance standards...

  2. Annual Performance Report for Vocational Education. Guam 1993-1994.

    ERIC Educational Resources Information Center

    Guam Community Coll., Agana. Office of the State Agency for Vocational and Adult Education.

    In 1992, the Guam System of Performance Measures and Standards for vocational education was adopted. In 1993-94, results of the performance measures and standards indicated the following: 68 percent of secondary students achieved the 0.5 grade growth in reading; about 90 percent of postsecondary students scored a mean gain of 1.2, well over the…

  3. Measuring Performance with Library Automated Systems.

    ERIC Educational Resources Information Center

    OFarrell, John P.

    2000-01-01

    Investigates the capability of three library automated systems to generate some of the datasets necessary to form the ISO (International Standards Organization) standard on performance measurement within libraries, based on research in Liverpool John Moores University (United Kingdom). Concludes that the systems are weak in generating the…

  4. [Mobile Health: IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices].

    PubMed

    Zhou, Xia; Wu, Wenli; Bao, Shudi

    2015-07-01

    IEEE Std 1708-2014 breaks through the traditional standards of cuff based blood pressure measuring devices and establishes a normative definition of wearable cuffless blood pressure measuring devices and the objective performance evaluation of this kind of devices. This study firstly introduces the background of the new standard. Then, the standard details will be described, and the impact of cuffless blood pressure measuring devices with the new standard on manufacturers and end users will be addressed.

  5. Standardization of Sonographic Lung-to-Head Ratio Measurements in Isolated Congenital Diaphragmatic Hernia: Impact on the Reproducibility and Efficacy to Predict Outcomes.

    PubMed

    Britto, Ingrid Schwach Werneck; Sananes, Nicolas; Olutoye, Oluyinka O; Cass, Darrell L; Sangi-Haghpeykar, Haleh; Lee, Timothy C; Cassady, Christopher I; Mehollin-Ray, Amy; Welty, Stephen; Fernandes, Caraciolo; Belfort, Michael A; Lee, Wesley; Ruano, Rodrigo

    2015-10-01

    The purpose of this study was to evaluate the impact of standardization of the lung-to-head ratio measurements in isolated congenital diaphragmatic hernia on prediction of neonatal outcomes and reproducibility. We conducted a retrospective cohort study of 77 cases of isolated congenital diaphragmatic hernia managed in a single center between 2004 and 2012. We compared lung-to-head ratio measurements that were performed prospectively in our institution without standardization to standardized measurements performed according to a defined protocol. The standardized lung-to-head ratio measurements were statistically more accurate than the nonstandardized measurements for predicting neonatal mortality (area under the receiver operating characteristic curve, 0.85 versus 0.732; P = .003). After standardization, there were no statistical differences in accuracy between measurements regardless of whether we considered observed-to-expected values (P > .05). Standardization of the lung-to-head ratio did not improve prediction of the need for extracorporeal membrane oxygenation (P> .05). Both intraoperator and interoperator reproducibility were good for the standardized lung-to-head ratio (intraclass correlation coefficient, 0.98 [95% confidence interval, 0.97-0.99]; bias, 0.02 [limits of agreement, -0.11 to +0.15], respectively). Standardization of lung-to-head ratio measurements improves prediction of neonatal outcomes. Further studies are needed to confirm these results and to assess the utility of standardization of other prognostic parameters.

  6. The impact of leadership and team behavior on standard of care delivered during human patient simulation: a pilot study for undergraduate medical students.

    PubMed

    Carlson, Jim; Min, Elana; Bridges, Diane

    2009-01-01

    Methodology to train team behavior during simulation has received increased attention, but standard performance measures are lacking, especially at the undergraduate level. Our purposes were to develop a reliable team behavior measurement tool and explore the relationship between team behavior and the delivery of an appropriate standard of care specific to the simulated case. Authors developed a unique team measurement tool based on previous work. Trainees participated in a simulated event involving the presentation of acute dyspnea. Performance was rated by separate raters using the team behavior measurement tool. Interrater reliability was assessed. The relationship between team behavior and the standard of care delivered was explored. The instrument proved to be reliable for this case and group of raters. Team behaviors had a positive relationship with the standard of medical care delivered specific to the simulated case. The methods used provide a possible method for training and assessing team performance during simulation.

  7. Standard Practices for Usage of Inductive Magnetic Field Probes with Application to Electric Propulsion Testing

    NASA Technical Reports Server (NTRS)

    Polzin, Kurt A.; Hill, Carrie S.; Turchi, Peter J.; Burton, Rodney L.; Messer, Sarah; Lovberg, Ralph H.; Hallock, Ashley K.

    2013-01-01

    Inductive magnetic field probes (also known as B-dot probes and sometimes as B-probes or magnetic probes) are often employed to perform field measurements in electric propulsion applications where there are time-varying fields. Magnetic field probes provide the means to measure these magnetic fields and can even be used to measure the plasma current density indirectly through the application of Ampere's law. Measurements of this type can yield either global information related to a thruster and its performance or detailed, local data related to the specific physical processes occurring in the plasma. Results of the development of a standard for B-dot probe measurements are presented, condensing the available literature on the subject into an accessible set of rules, guidelines, and techniques to standardize the performance and presentation of future measurements.

  8. 40 CFR 230.95 - Ecological performance standards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... mitigation plan must contain performance standards that will be used to assess whether the project is... mitigation project, so that the project can be objectively evaluated to determine if it is developing into... verifiable. Ecological performance standards must be based on the best available science that can be measured...

  9. 40 CFR 230.95 - Ecological performance standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... mitigation plan must contain performance standards that will be used to assess whether the project is... mitigation project, so that the project can be objectively evaluated to determine if it is developing into... verifiable. Ecological performance standards must be based on the best available science that can be measured...

  10. 40 CFR 230.95 - Ecological performance standards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... mitigation plan must contain performance standards that will be used to assess whether the project is... mitigation project, so that the project can be objectively evaluated to determine if it is developing into... verifiable. Ecological performance standards must be based on the best available science that can be measured...

  11. Standards Performance Continuum: Development and Validation of a Measure of Effective Pedagogy.

    ERIC Educational Resources Information Center

    Doherty, R. William; Hilberg, R. Soleste; Epaloose, Georgia; Tharp, Roland G.

    2002-01-01

    Describes the development and validation of the Standards Performance Continuum (SPC) for assessing teacher performance of the Standards for Effective Pedagogy. Three studies involving Florida, California, and New Mexico public school teachers provided evidence of inter-rater reliability, concurrent validity, and criterion-related validity…

  12. 40 CFR 230.95 - Ecological performance standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... mitigation plan must contain performance standards that will be used to assess whether the project is... mitigation project, so that the project can be objectively evaluated to determine if it is developing into... verifiable. Ecological performance standards must be based on the best available science that can be measured...

  13. "Circumstance and Proper Timing": Context and the Construction of a Standards Framework for School Principals' Performance.

    ERIC Educational Resources Information Center

    Louden, William; Wildy, Helen

    1999-01-01

    Professional standards for school principals typically describe an ideal performance in a generalized context. This article describes an alternative method of developing a standards framework, combining qualitative vignettes with probabilistic measurement techniques to provide essential or ideal performance qualities with contextually rich…

  14. Testing of CMA-2000 Microwave Landing System (MLS) airborne receiver

    NASA Astrophysics Data System (ADS)

    Labreche, L.; Murfin, A. J.

    1989-09-01

    Microwave landing system (MLS) is a precision approach and landing guidance system which provides position information and various air to ground data. Position information is provided on a wide coverage sector and is determined by an azimuth angle measurement, an elevation angle measurement, and a range measurement. MLS performance standards and testing of the MLS airborne receiver is mainly governed by Technical Standard Order TSO-C104 issued by the Federal Aviation Administration. This TSO defines detailed test procedures for use in determining the required performance under standard and stressed conditions. It also imposes disciplines on software development and testing procedures. Testing performed on the CMA-2000 MLS receiver and methods used in its validation are described. A computer automated test system has been developed to test for compliance with RTCA/DO-177 Minimum Operation Performance Standards. Extensive software verification and traceability tests designed to ensure compliance with RTCA/DO-178 are outlined.

  15. The Future Is Performance Assessment

    ERIC Educational Resources Information Center

    French, Dan

    2017-01-01

    As more people question the value of standardized testing, the public appetite for a change in the accountability system grows. A 2016 national survey found that "voters consider standardized tests the least important factor in measuring the performance of students," preferring instead to have a multiple-measures data dashboard of…

  16. 40 CFR 60.704 - Test methods and procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Volatile Organic Compound Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Reactor Processes § 60... compound j in ppm, as measured for organics by Method 18 and measured for hydrogen and carbon monoxide by...

  17. 40 CFR 60.704 - Test methods and procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Volatile Organic Compound Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Reactor Processes § 60... basis of compound j in ppm, as measured for organics by Method 18 and measured for hydrogen and carbon...

  18. Advanced Ceramics Property and Performance Measurements

    NASA Technical Reports Server (NTRS)

    Jenkins, Michael; Salem, Jonathan; Helfinstine, John; Quinn, George; Gonczy, Stephen

    2015-01-01

    Mechanical and physical properties of ceramic bodies can be difficult to measure correctly unless the proper techniques are used. The Advanced Ceramics Committee of ASTM, C-28, has developed dozens of consensus test standards and practices to measure various properties of a ceramic monolith, composite, or coating. The standards give the what, how, how not, and why for measurement of many mechanical, physical, thermal, and performance properties. Using these standards will provide accurate, reliable, and complete data for rigorous comparisons with other test results from your test lab, or another. The C-28 Committee has involved academics, producers, and users of ceramics to write and continually update more than 45 standards since the committees inception in 1986. Included in this poster is a pictogram of the C-28 standards and information on how to obtain individual copies with full details or the complete collection of all of the standards in one volume.

  19. UV scale calibration transfer from an improved pyroelectric detector standard to field UV-A meters and 365 nm excitation sources

    NASA Astrophysics Data System (ADS)

    Eppeldauer, G. P.; Podobedov, V. B.; Cooksey, C. C.

    2017-05-01

    Calibration of the emitted radiation from UV sources peaking at 365 nm, is necessary to perform the ASTM required 1 mW/cm2 minimum irradiance in certain military material (ships, airplanes etc) tests. These UV "black lights" are applied for crack-recognition using fluorescent liquid penetrant inspection. At present, these nondestructive tests are performed using Hg-lamps. Lack of a proper standard and the different spectral responsivities of the available UV meters cause significant measurement errors even if the same UV-365 source is measured. A pyroelectric radiometer standard with spectrally flat (constant) response in the UV-VIS range has been developed to solve the problem. The response curve of this standard determined from spectral reflectance measurement, is converted into spectral irradiance responsivity with <0.5% (k=2) uncertainty as a result of using an absolute tie point from a Si-trap detector traceable to the primary standard cryogenic radiometer. The flat pyroelectric radiometer standard can be used to perform uniform integrated irradiance measurements from all kinds of UV sources (with different peaks and distributions) without using any source standard. Using this broadband calibration method, yearly spectral calibrations for the reference UV (LED) sources and irradiance meters is not needed. Field UV sources and meters can be calibrated against the pyroelectric radiometer standard for broadband (integrated) irradiance and integrated responsivity. Using the broadband measurement procedure, the UV measurements give uniform results with significantly decreased uncertainties.

  20. Performance measures for rural transportation systems : guidebook.

    DOT National Transportation Integrated Search

    2006-06-01

    This Performance Measures for Rural Transportation Systems Guidebook provides a : standardized and supportable performance measurement process that can be applied to : transportation systems in rural areas. The guidance included in this guidebook was...

  1. A Step Towards Electric Propulsion Testing Standards: Pressure Measurements and Effective Pumping Speeds

    NASA Technical Reports Server (NTRS)

    Dankanich, John W.; Swiatek, Michael W.; Yim, John T.

    2012-01-01

    The electric propulsion community has been implored to establish and implement a set of universally applicable test standards during the research, development, and qualification of electric propulsion systems. Existing practices are fallible and result in testing variations which leads to suspicious results, large margins in application, or aversion to mission infusion. Performance measurements and life testing under appropriate conditions can be costly and lengthy. Measurement practices must be consistent, accurate, and repeatable. Additionally, the measurements must be universally transportable across facilities throughout the development, qualification, spacecraft integration and on-orbit performance. A preliminary step to progress towards universally applicable testing standards is outlined for facility pressure measurements and effective pumping speed calculations. The standard has been applied to multiple facilities at the NASA Glenn Research Center. Test results and analyses of universality of measurements are presented herein.

  2. ASTM Committee C28: International Standards for Properties and Performance of Advanced Ceramics, Three Decades of High-quality, Technically-rigorous Normalization

    NASA Technical Reports Server (NTRS)

    Jenkins, Michael G.; Salem, Jonathan A.

    2016-01-01

    Physical and mechanical properties and performance of advanced ceramics and glasses are difficult to measure correctly without the proper techniques. For over three decades, ASTM Committee C28 on Advanced Ceramics, has developed high quality, rigorous, full-consensus standards (e.g., test methods, practices, guides, terminology) to measure properties and performance of monolithic and composite ceramics that may be applied to glasses in some cases. These standards testing particulars for many mechanical, physical, thermal, properties and performance of these materials. As a result these standards provide accurate, reliable, repeatable and complete data. Within Committee C28 users, producers, researchers, designers, academicians, etc. have written, continually updated, and validated through round-robin test programs, nearly 50 standards since the Committees founding in 1986. This paper provides a retrospective review of the 30 years of ASTM Committee C28 including a graphical pictogram listing of C28 standards along with examples of the tangible benefits of advanced ceramics standards to demonstrate their practical applications.

  3. Behavioral Health and Performance Laboratory Standard Measures (BHP-SM)

    NASA Technical Reports Server (NTRS)

    Williams, Thomas J.; Cromwell, Ronita

    2017-01-01

    The Spaceflight Standard Measures is a NASA Johnson Space Center Human Research Project (HRP) project that proposes to collect a set of core measurements, representative of many of the human spaceflight risks, from astronauts before, during and after long-duration International Space Station (ISS) missions. The term "standard measures" is defined as a set of core measurements, including physiological, biochemical, psychosocial, cognitive, and functional, that are reliable, valid, and accepted in terrestrial science, are associated with a specific and measurable outcome known to occur as a consequence of spaceflight, that will be collected in a standardized fashion from all (or most) crewmembers. While such measures might be used to define standards of health and performance or readiness for flight, the prime intent in their collection is to allow longitudinal analysis of multiple parameters in order to answer a variety of operational, occupational, and research-based questions. These questions are generally at a high level, and the approach for this project is to populate the standard measures database with the smallest set of data necessary to indicate further detailed research is required. Also included as standard measures are parameters that are not outcome-based in and of-themselves, but provide ancillary information that supports interpretation of the outcome measures, e.g., nutritional assessment, vehicle environmental parameters, crew debriefs, etc. The project's main aim is to ensure that an optimized minimal set of measures is consistently captured from all ISS crewmembers until the end of Station in order to characterize the human in space. -This allows the HRP to identify, establish, and evaluate a common set of measures for use in spaceflight and analog research to: develop baselines, systematically characterize risk likelihood and consequences, and assess effectiveness of countermeasures that work for behavioral health and performance risk factors. -By standardizing the battery of measures on all crewmembers, it will allow the HRP to evaluate countermeasures that work for one physiological system and ensure another system is not negatively affected. -These measures, named "Standard Measures," will serve as a data repository and be available to other studies under data sharing agreements.

  4. Absolute Frequency Measurements with a Set of Transportable HE-NE/CH4 Optical Frequency Standards and Prospects for Future Design and Applications

    NASA Astrophysics Data System (ADS)

    Gubin, M.; Kovalchuk, E.; Petrukhin, E.; Shelkovnikov, A.; Tyurikov, D.; Gamidov, R.; Erdogan, C.; Sahin, E.; Felder, R.; Gill, P.; Lea, S. N.; Kramer, G.; Lipphardt, B.

    2002-04-01

    The accumulated results of absolute frequency measurements (AFM) carried out in 1997-2000 with transportable double-mode He-Ne/CH4 optical frequency standards (λ = 3 .39μm) in a collaboration of several laboratories are presented. The performance of this secondary optical frequency standard is estimated on the level of 10-13 (in repeatability), and 1 × 10-14/s (in stability). The next steps towards He-Ne/CH4 standards with one order of magnitude better performance, including devices based on monolithic zerodur resonators, are discussed. Important applications of transportable He-Ne/CH4 optical frequency standards have appeared now due to dramatic progress in the field of optical frequency measurements. Used to stabilize the repetition rate of a Ti:Sa fs laser, these compact secondary standards can transfer their performance into the whole optical range covered by a fs comb. Thus they can play the role of a narrow spectrum interrogative oscillator for super-accurate optical or microwave frequency standards substituting in some tasks a H-maser or oscillators based on cryogenic sapphire resonators.

  5. 2 CFR 200.301 - Performance measurement.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 2 Grants and Agreements 1 2014-01-01 2014-01-01 false Performance measurement. 200.301 Section 200... § 200.301 Performance measurement. The Federal awarding agency must require the recipient to use OMB-approved governmentwide standard information collections when providing financial and performance...

  6. Relevance of methods and standards for the assessment of measurement system performance in a High-Value Manufacturing Industry

    NASA Astrophysics Data System (ADS)

    Loftus, Pete; Giudice, Seb

    2014-08-01

    Measurements underpin the engineering decisions that allow products to be designed, manufactured, operated, and maintained. Therefore, the quality of measured data needs to be systematically assured to allow decision makers to proceed with confidence. The use of standards is one way of achieving this. This paper explores the relevance of international documentary standards to the assessment of measurement system capability in High Value Manufacturing (HVM) Industry. An internal measurement standard is presented which supplements these standards and recommendations are made for a cohesive effort to develop the international standards to provide consistency in such industrial applications.

  7. Quantum Standard Teleportation Based on the Generic Measurement Bases

    NASA Astrophysics Data System (ADS)

    Hao, San-Ru; Hou, Bo-Yu; Xi, Xiao-Qiang; Yue, Rui-Hong

    2003-10-01

    We study the quantum standard teleportation based on the generic measurement bases. It is shown that the quantum standard teleportation does not depend on the explicit expression of the measurement bases. We have given the correspondence relation between the measurement performed by Alice and the unitary transformation performed by Bob. We also prove that the single particle unknown states and the two-particle unknown cat-like states can be exactly transmitted by means of the generic measurement bases and the correspondence unitary transformations. The project supported in part by National Natural Science Foundation of China, the Hunan Provincial Natural Science Foundation of China, and the Scientific Research Fund of Hunan Provincial Education Department

  8. Specifying and Pilot Testing Quality Measures for the American Society of Addiction Medicine's Standards of Care.

    PubMed

    Harris, Alex H S; Weisner, Constance M; Chalk, Mady; Capoccia, Victor; Chen, Cheng; Thomas, Cindy Parks

    2016-01-01

    In 2013, the American Society of Addiction Medicine (ASAM) approved its Standards of Care for the Addiction Specialist Physician. Subsequently, an ASAM Performance Measures Panel identified and prioritized the standards to be operationalized into performance measures. The goal of this study is to describe the process of operationalizing 3 of these standards into quality measures, and to present the initial measure specifications and results of pilot testing these measures in a large health care system. By presenting the process rather than just the end results, we hope to shed light on the measure development process to educate, and also to stimulate debate about the decisions that were made. Each measure was decomposed into major concepts. Then each concept was operationalized using commonly available administrative data sources. Alternative specifications examined and sensitivity analyses were conducted to inform decisions that balanced accuracy, clinical nuance, and simplicity. Using data from the US Veterans Health Administration (VHA), overall performance and variation in performance across 119 VHA facilities were calculated. Three measures were operationalized and pilot tested: pharmacotherapy for alcohol use disorder, pharmacotherapy for opioid use disorder, and timely follow-up after medically managed withdrawal (aka detoxification). Each measure was calculable with available data, and showed ample room for improvement (no ceiling effects) and wide facility-level variability. Next steps include conducting feasibility and pilot testing in other health care systems and other contexts such as standalone addiction treatment programs, and also to study the specification and predictive validity of these measures.

  9. Collaborative Radiological Response Planning

    DTIC Science & Technology

    2013-12-01

    280-5500 Standard Form 298 (Rev. 2–89) Prescribed by ANSI Std. 239–18 i THIS PAGE INTENTIONALLY LEFT BLANK ii Approved for public release...critical tasks, under specified conditions and performance standards .”33 Aligned with the central objective of Capabilities-Based Planning, the TCL...affect task performance.36 More specifically, measures and performance criteria describe a standard for how well a task must be performed and on

  10. Validating Functional Measures of Physical Ability for Aging People with Intellectual Developmental Disability

    ERIC Educational Resources Information Center

    Maring, Joyce R.; Costello, Ellen; Birkmeier, Marisa C.; Richards, Maggie; Alexander, Lisa M.

    2013-01-01

    Unlike the aging population without intellectual and developmental disabilities (IDD), few standardized performance measures exist to assess physical function and risk for adverse outcomes such as nonfatal, unintentional injuries. We modified 3 selected standardized performance tools in the areas of general fitness (2-Minute Walk Test), balance…

  11. Performance Standards and Domains of College Students' Personal Accomplishments.

    ERIC Educational Resources Information Center

    Gaeddert, William P.; And Others

    A number of researchers have described individual differences in achievement goals and performance standards. To explore similarities and differences in these theories, and to provide an instrument to measure them, 273 female and 88 male college students responded to items designed to measure each of the dimensions defined by these theories. The…

  12. Comparing Performance Standards on the Retention of Words Read Correctly per Minute

    ERIC Educational Resources Information Center

    Kubina, Richard M., Jr.; Amato, Janelle; Schwilk, Christopher L.; Therrien, William J.

    2008-01-01

    To measure retention of oral reading fluency, three students attending a learning support classroom used a repeating reading strategy with two passages. Each student read one passage to a high performance standard and the other passage to a lower performance standard. Results show it took the students more practice to reach the higher performance…

  13. Performance Standards for Windows | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  14. The Utility of Curriculum-Based Measurement within a Multitiered Framework: Establishing Cut Scores as Predictors of Student Performance on the Alaska Standards-Based Assessment

    ERIC Educational Resources Information Center

    Legg, David E.

    2013-01-01

    The purpose of this study was to explore the relationship between student performance on Reading Curriculum-based Measures (R-CBM) and student performance on the Alaska's standards based assessment (SBA) administered to students in Studied School District (SSD) Grade 3 through Grade 5 students in the Studied School District as required by…

  15. Standardization of Broadband UV Measurements for 365 nm LED Sources

    PubMed Central

    Eppeldauer, George P.

    2012-01-01

    Broadband UV measurements are evaluated when UV-A irradiance meters measure optical radiation from 365 nm UV sources. The CIE standardized rectangular-shape UV-A function can be realized only with large spectral mismatch errors. The spectral power-distribution of the 365 nm excitation source is not standardized. Accordingly, the readings made with different types of UV meters, even if they measure the same UV source, can be very different. Available UV detectors and UV meters were measured and evaluated for spectral responsivity. The spectral product of the source-distribution and the meter’s spectral-responsivity were calculated for different combinations to estimate broad-band signal-measurement errors. Standardization of both the UV source-distribution and the meter spectral-responsivity is recommended here to perform uniform broad-band measurements with low uncertainty. It is shown what spectral responsivity function(s) is needed for new and existing UV irradiance meters to perform low-uncertainty broadband 365 nm measurements. PMID:26900516

  16. National Unmanned Aerial System Standardized Performance Testing and Rating (NUSTAR)

    NASA Technical Reports Server (NTRS)

    Kopardekar, Parimal

    2016-01-01

    The overall objective of the NUSTAR Capability is to offer standardized tests and scenario conditions to assess performance of the UAS. The following are goals of the NU-STAR: 1. Create a prototype standardized tests and scenarios that vehicles can be tested against. 2. Identify key performance parameters of all UAS and their standardized measurement strategy. 3. Develop standardized performance reporting method (e.g., consumer report style) to assist prospective buyers. 4. Identify key performance metrics that could be used by judged towards overall safety of the UAS and operations. 5. If vehicle certification standard is made by a regulatory agency, the performance of individual UAS could be compared against the minimum requirement (e.g., sense and avoid detection time, stopping distance, kinetic energy, etc.).

  17. 34 CFR 403.202 - What must each State's system of core standards and measures of performance include?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 34 Education 3 2013-07-01 2013-07-01 false What must each State's system of core standards and measures of performance include? 403.202 Section 403.202 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF VOCATIONAL AND ADULT EDUCATION, DEPARTMENT OF EDUCATION STATE...

  18. 34 CFR 403.202 - What must each State's system of core standards and measures of performance include?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 34 Education 3 2012-07-01 2012-07-01 false What must each State's system of core standards and measures of performance include? 403.202 Section 403.202 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF VOCATIONAL AND ADULT EDUCATION, DEPARTMENT OF EDUCATION STATE...

  19. 34 CFR 403.202 - What must each State's system of core standards and measures of performance include?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 34 Education 3 2014-07-01 2014-07-01 false What must each State's system of core standards and measures of performance include? 403.202 Section 403.202 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF VOCATIONAL AND ADULT EDUCATION, DEPARTMENT OF EDUCATION STATE...

  20. 34 CFR 403.202 - What must each State's system of core standards and measures of performance include?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 34 Education 3 2011-07-01 2011-07-01 false What must each State's system of core standards and measures of performance include? 403.202 Section 403.202 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF VOCATIONAL AND ADULT EDUCATION, DEPARTMENT OF EDUCATION STATE...

  1. 10 CFR 625.3 - Standard sales provisions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... conditions of sale, and purchaser financial and performance responsibility measures, or descriptions thereof... and conditions, or financial and performance responsibility measures, shall apply to a particular sale... contractual provisions and financial and performance responsibility measures which the Notice of Sale makes...

  2. 10 CFR 625.3 - Standard sales provisions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... conditions of sale, and purchaser financial and performance responsibility measures, or descriptions thereof... and conditions, or financial and performance responsibility measures, shall apply to a particular sale... contractual provisions and financial and performance responsibility measures which the Notice of Sale makes...

  3. ASTM Committee C28: International Standards for Properties and Performance of Advanced Ceramics-Three Decades of High-Quality, Technically-Rigorous Normalization

    NASA Technical Reports Server (NTRS)

    Jenkins, Michael G.; Salem, Jonathan A.

    2016-01-01

    Physical and mechanical properties and performance of advanced ceramics and glasses are difficult to measure correctly without the proper techniques. For over three decades, ASTM Committee C28 on Advanced Ceramics, has developed high-quality, technically-rigorous, full-consensus standards (e.g., test methods, practices, guides, terminology) to measure properties and performance of monolithic and composite ceramics that may be applied to glasses in some cases. These standards contain testing particulars for many mechanical, physical, thermal, properties and performance of these materials. As a result these standards are used to generate accurate, reliable, repeatable and complete data. Within Committee C28, users, producers, researchers, designers, academicians, etc. have written, continually updated, and validated through round-robin test programs, 50 standards since the Committee's founding in 1986. This paper provides a detailed retrospective of the 30 years of ASTM Committee C28 including a graphical pictogram listing of C28 standards along with examples of the tangible benefits of standards for advanced ceramics to demonstrate their practical applications.

  4. Expert opinions and scientific evidence for colonoscopy key performance indicators.

    PubMed

    Rees, Colin J; Bevan, Roisin; Zimmermann-Fraedrich, Katharina; Rutter, Matthew D; Rex, Douglas; Dekker, Evelien; Ponchon, Thierry; Bretthauer, Michael; Regula, Jaroslaw; Saunders, Brian; Hassan, Cesare; Bourke, Michael J; Rösch, Thomas

    2016-12-01

    Colonoscopy is a widely performed procedure with procedural volumes increasing annually throughout the world. Many procedures are now performed as part of colorectal cancer screening programmes. Colonoscopy should be of high quality and measures of this quality should be evidence based. New UK key performance indicators and quality assurance standards have been developed by a working group with consensus agreement on each standard reached. This paper reviews the scientific basis for each of the quality measures published in the UK standards. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  5. Predictive Accuracy of Sweep Frequency Impedance Technology in Identifying Conductive Conditions in Newborns.

    PubMed

    Aithal, Venkatesh; Kei, Joseph; Driscoll, Carlie; Murakoshi, Michio; Wada, Hiroshi

    2018-02-01

    Diagnosing conductive conditions in newborns is challenging for both audiologists and otolaryngologists. Although high-frequency tympanometry (HFT), acoustic stapedial reflex tests, and wideband absorbance measures are useful diagnostic tools, there is performance measure variability in their detection of middle ear conditions. Additional diagnostic sensitivity and specificity measures gained through new technology such as sweep frequency impedance (SFI) measures may assist in the diagnosis of middle ear dysfunction in newborns. The purpose of this study was to determine the test performance of SFI to predict the status of the outer and middle ear in newborns against commonly used reference standards. Automated auditory brainstem response (AABR), HFT (1000 Hz), transient evoked otoacoustic emission (TEOAE), distortion product otoacoustic emission (DPOAE), and SFI tests were administered to the study sample. A total of 188 neonates (98 males and 90 females) with a mean gestational age of 39.4 weeks were included in the sample. Mean age at the time of testing was 44.4 hr. Diagnostic accuracy of SFI was assessed in terms of its ability to identify conductive conditions in neonates when compared with nine different reference standards (including four single tests [AABR, HFT, TEOAE, and DPOAE] and five test batteries [HFT + DPOAE, HFT + TEOAE, DPOAE + TEOAE, DPOAE + AABR, and TEOAE + AABR]), using receiver operating characteristic (ROC) analysis and traditional test performance measures such as sensitivity and specificity. The test performance of SFI against the test battery reference standard of HFT + DPOAE and single reference standard of HFT was high with an area under the ROC curve (AROC) of 0.87 and 0.82, respectively. Although the HFT + DPOAE test battery reference standard performed better than the HFT reference standard in predicting middle ear conductive conditions in neonates, the difference in AROC was not significant. Further analysis revealed that the highest sensitivity and specificity for SFI (86% and 88%, respectively) was obtained when compared with the reference standard of HFT + DPOAE. Among the four single reference standards, SFI had the highest sensitivity and specificity (76% and 88%, respectively) when compared against the HFT reference standard. The high test performance of SFI against the HFT and HFT + DPOAE reference standards indicates that the SFI measure has appropriate diagnostic accuracy in detection of conductive conditions in newborns. Hence, the SFI test could be used as adjunct tool to identify conductive conditions in universal newborn hearing screening programs, and can also be used in diagnostic follow-up assessments. American Academy of Audiology

  6. Assessment of a Microsoft Kinect-based 3D scanning system for taking body segment girth measurements: a comparison to ISAK and ISO standards.

    PubMed

    Clarkson, Sean; Wheat, Jon; Heller, Ben; Choppin, Simon

    2016-01-01

    Use of anthropometric data to infer sporting performance is increasing in popularity, particularly within elite sport programmes. Measurement typically follows standards set by the International Society for the Advancement of Kinanthropometry (ISAK). However, such techniques are time consuming, which reduces their practicality. Schranz et al. recently suggested 3D body scanners could replace current measurement techniques; however, current systems are costly. Recent interest in natural user interaction has led to a range of low-cost depth cameras capable of producing 3D body scans, from which anthropometrics can be calculated. A scanning system comprising 4 depth cameras was used to scan 4 cylinders, representative of the body segments. Girth measurements were calculated from the 3D scans and compared to gold standard measurements. Requirements of a Level 1 ISAK practitioner were met in all 4 cylinders, and ISO standards for scan-derived girth measurements were met in the 2 larger cylinders only. A fixed measurement bias was identified that could be corrected with a simple offset factor. Further work is required to determine comparable performance across a wider range of measurements performed upon living participants. Nevertheless, findings of the study suggest such a system offers many advantages over current techniques, having a range of potential applications.

  7. 45 CFR 305.31 - Amount of incentive payment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... PROGRAM PERFORMANCE MEASURES, STANDARDS, FINANCIAL INCENTIVES, AND PENALTIES § 305.31 Amount of incentive... establishment, support order, and current collections performance measures and 75 percent of the State's collections base for the fiscal year for the arrearage collections and cost-effectiveness performance measures...

  8. Mobile Robot and Mobile Manipulator Research Towards ASTM Standards Development.

    PubMed

    Bostelman, Roger; Hong, Tsai; Legowik, Steven

    2016-01-01

    Performance standards for industrial mobile robots and mobile manipulators (robot arms onboard mobile robots) have only recently begun development. Low cost and standardized measurement techniques are needed to characterize system performance, compare different systems, and to determine if recalibration is required. This paper discusses work at the National Institute of Standards and Technology (NIST) and within the ASTM Committee F45 on Driverless Automatic Guided Industrial Vehicles. This includes standards for both terminology, F45.91, and for navigation performance test methods, F45.02. The paper defines terms that are being considered. Additionally, the paper describes navigation test methods that are near ballot and docking test methods being designed for consideration within F45.02. This includes the use of low cost artifacts that can provide alternatives to using relatively expensive measurement systems.

  9. Mobile Robot and Mobile Manipulator Research Towards ASTM Standards Development

    PubMed Central

    Bostelman, Roger; Hong, Tsai; Legowik, Steven

    2017-01-01

    Performance standards for industrial mobile robots and mobile manipulators (robot arms onboard mobile robots) have only recently begun development. Low cost and standardized measurement techniques are needed to characterize system performance, compare different systems, and to determine if recalibration is required. This paper discusses work at the National Institute of Standards and Technology (NIST) and within the ASTM Committee F45 on Driverless Automatic Guided Industrial Vehicles. This includes standards for both terminology, F45.91, and for navigation performance test methods, F45.02. The paper defines terms that are being considered. Additionally, the paper describes navigation test methods that are near ballot and docking test methods being designed for consideration within F45.02. This includes the use of low cost artifacts that can provide alternatives to using relatively expensive measurement systems. PMID:28690359

  10. On the Performance Evaluation of 3D Reconstruction Techniques from a Sequence of Images

    NASA Astrophysics Data System (ADS)

    Eid, Ahmed; Farag, Aly

    2005-12-01

    The performance evaluation of 3D reconstruction techniques is not a simple problem to solve. This is not only due to the increased dimensionality of the problem but also due to the lack of standardized and widely accepted testing methodologies. This paper presents a unified framework for the performance evaluation of different 3D reconstruction techniques. This framework includes a general problem formalization, different measuring criteria, and a classification method as a first step in standardizing the evaluation process. Performance characterization of two standard 3D reconstruction techniques, stereo and space carving, is also presented. The evaluation is performed on the same data set using an image reprojection testing methodology to reduce the dimensionality of the evaluation domain. Also, different measuring strategies are presented and applied to the stereo and space carving techniques. These measuring strategies have shown consistent results in quantifying the performance of these techniques. Additional experiments are performed on the space carving technique to study the effect of the number of input images and the camera pose on its performance.

  11. Crisis Reliability Indicators Supporting Emergency Services (CRISES): A Framework for Developing Performance Measures for Behavioral Health Crisis and Psychiatric Emergency Programs.

    PubMed

    Balfour, Margaret E; Tanner, Kathleen; Jurica, Paul J; Rhoads, Richard; Carson, Chris A

    2016-01-01

    Crisis and emergency psychiatric services are an integral part of the healthcare system, yet there are no standardized measures for programs providing these services. We developed the Crisis Reliability Indicators Supporting Emergency Services (CRISES) framework to create measures that inform internal performance improvement initiatives and allow comparison across programs. The framework consists of two components-the CRISES domains (timely, safe, accessible, least-restrictive, effective, consumer/family centered, and partnership) and the measures supporting each domain. The CRISES framework provides a foundation for development of standardized measures for the crisis field. This will become increasingly important as pay-for-performance initiatives expand with healthcare reform.

  12. Position Measurement Standard Evaluation

    DOT National Transportation Integrated Search

    1975-02-01

    The objectives of the Position Measurement Standard Program were to collect navigation data from three DME receivers and a low-frequency GLOBAL Navigation system, and evaluate their relative performance against a reference radar. Flight test data dur...

  13. The Software Maturity Matrix: A Software Performance Metric

    DTIC Science & Technology

    2003-01-28

    are for Managing n Use Them! n Unused measurements have the same value as last night’s unused hotel room or an empty airline seat. n Be Prepared to...standard measurements are implicit n Organization standard verification is implicit n Organization standard SMM training can be the basis of an

  14. 40 CFR 432.105 - New source performance standards (NSPS).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...: Performance Standards [NSPS] Regulatedparameter Maximum daily Maximum monthly avg. Ammonia (as N) 1 0.14 0.07... No maximum monthly average limitation. 4 May be measured as hexane extractable material (HEM). 5 mg/L...

  15. 40 CFR 432.105 - New source performance standards (NSPS).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...: Performance Standards [NSPS] Regulatedparameter Maximum daily Maximum monthly avg. Ammonia (as N) 1 0.14 0.07... No maximum monthly average limitation. 4 May be measured as hexane extractable material (HEM). 5 mg/L...

  16. 40 CFR 432.105 - New source performance standards (NSPS).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...: Performance Standards [NSPS] Regulatedparameter Maximum daily Maximum monthly avg. Ammonia (as N) 1 0.14 0.07... No maximum monthly average limitation. 4 May be measured as hexane extractable material (HEM). 5 mg/L...

  17. Performance Evaluation of Phasor Measurement Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Zhenyu; Kasztenny, Bogdan; Madani, Vahid

    2008-07-20

    After two decades of phasor network deployment, phasor measurements are now available at many major substations and power plants. The North American SynchroPhasor Initiative (NASPI), supported by both the US Department of Energy and the North American Electricity Reliability Council (NERC), provides a forum to facilitate the efforts in phasor technology in North America. Phasor applications have been explored and some are in today’s utility practice. IEEE C37.118 Standard is a milestone in standardizing phasor measurements and defining performance requirements. To comply with IEEE C37.118 and to better understand the impact of phasor quality on applications, the NASPI Performance andmore » Standards Task Team (PSTT) initiated and accomplished the development of two important documents to address characterization of PMUs and instrumentation channels, which leverage prior work (esp. in WECC) and international experience. This paper summarizes the accomplished PSTT work and presents the methods for phasor measurement evaluation.« less

  18. The cooking task: making a meal of executive functions

    PubMed Central

    Doherty, T. A.; Barker, L. A.; Denniss, R.; Jalil, A.; Beer, M. D.

    2015-01-01

    Current standardized neuropsychological tests may fail to accurately capture real-world executive deficits. We developed a computer-based Cooking Task (CT) assessment of executive functions and trialed the measure with a normative group before use with a head-injured population. Forty-six participants completed the computerized CT and subtests from standardized neuropsychological tasks, including the Tower and Sorting Tests of executive function from the Delis-Kaplan Executive Function System (D-KEFS) and the Cambridge prospective memory test (CAMPROMPT), in order to examine whether standardized executive function tasks, predicted performance on measurement indices from the CT. Findings showed that verbal comprehension, rule detection and prospective memory contributed to measures of prospective planning accuracy and strategy implementation of the CT. Results also showed that functions necessary for cooking efficacy differ as an effect of task demands (difficulty levels). Performance on rule detection, strategy implementation and flexible thinking executive function measures contributed to accuracy on the CT. These findings raise questions about the functions captured by present standardized tasks particularly at varying levels of difficulty and during dual-task performance. Our preliminary findings also indicate that CT measures can effectively distinguish between executive function and Full Scale IQ abilities. Results of the present study indicate that the CT shows promise as an ecologically valid measure of executive function for future use with a head-injured population and indexes selective executive function’s captured by standardized tests. PMID:25717294

  19. The cooking task: making a meal of executive functions.

    PubMed

    Doherty, T A; Barker, L A; Denniss, R; Jalil, A; Beer, M D

    2015-01-01

    Current standardized neuropsychological tests may fail to accurately capture real-world executive deficits. We developed a computer-based Cooking Task (CT) assessment of executive functions and trialed the measure with a normative group before use with a head-injured population. Forty-six participants completed the computerized CT and subtests from standardized neuropsychological tasks, including the Tower and Sorting Tests of executive function from the Delis-Kaplan Executive Function System (D-KEFS) and the Cambridge prospective memory test (CAMPROMPT), in order to examine whether standardized executive function tasks, predicted performance on measurement indices from the CT. Findings showed that verbal comprehension, rule detection and prospective memory contributed to measures of prospective planning accuracy and strategy implementation of the CT. Results also showed that functions necessary for cooking efficacy differ as an effect of task demands (difficulty levels). Performance on rule detection, strategy implementation and flexible thinking executive function measures contributed to accuracy on the CT. These findings raise questions about the functions captured by present standardized tasks particularly at varying levels of difficulty and during dual-task performance. Our preliminary findings also indicate that CT measures can effectively distinguish between executive function and Full Scale IQ abilities. Results of the present study indicate that the CT shows promise as an ecologically valid measure of executive function for future use with a head-injured population and indexes selective executive function's captured by standardized tests.

  20. 45 CFR 305.60 - Types and scope of Federal audits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... HUMAN SERVICES PROGRAM PERFORMANCE MEASURES, STANDARDS, FINANCIAL INCENTIVES, AND PENALTIES § 305.60... more frequently if the State fails to meet performance standards and reliability of data requirements... used to process the data in calculating performance indicators under this part; (b) Also, OCSE will...

  1. Perkins Core Performance Measures Results and Targets, 2000-2001.

    ERIC Educational Resources Information Center

    McHewitt, Earl R.; Taylor, Garry

    This is a report on 2000-2001 Perkins III core performance standards and measures for the Virginia Community College System (VCCS). Perkins performance measure definitions for the system were finalized with the Virginia and federal departments of education in fall 2000. Core indicators include: (1) student attainment, which measures academic and…

  2. Perkins Core Performance Measures: Results and Targets, 1999-2000.

    ERIC Educational Resources Information Center

    McHewitt, Earl R.; Taylor, Garry

    This document describes the Virginia Community College System (VCCS) Core Indicators for the Perkins III Core Performance Standards and Measures. Core indicators and measures include: (1) student attainment, measured by academic and technical skills; (2) completion, measured by graduation rate; (3) placement and persistence, measured by placement,…

  3. The performance of single and multi-collector ICP-MS instruments for fast and reliable 34S/32S isotope ratio measurements.

    PubMed

    Hanousek, Ondrej; Brunner, Marion; Pröfrock, Daniel; Irrgeher, Johanna; Prohaska, Thomas

    2016-11-14

    The performance and validation characteristics of different single collector inductively coupled plasma mass spectrometers based on different technical principles (ICP-SFMS, ICP-QMS in reaction and collision modes, and ICP-MS/MS) were evaluated in comparison to the performance of MC ICP-MS for fast and reliable S isotope ratio measurements. The validation included the determination of LOD, BEC, measurement repeatability, within-lab reproducibility and deviation from certified values as well as a study on instrumental isotopic fractionation (IIF) and the calculation of the combined standard measurement uncertainty. Different approaches of correction for IIF applying external intra-elemental IIF correction (aka standard-sample bracketing) using certified S reference materials and internal inter-elemental IIF (aka internal standardization) correction using Si isotope ratios in MC ICP-MS are explained and compared. The resulting combined standard uncertainties of examined ICP-QMS systems were not better than 0.3-0.5% ( u c,rel ), which is in general insufficient to differentiate natural S isotope variations. Although the performance of the single collector ICP-SFMS is better (single measurement u c,rel = 0.08%), the measurement reproducibility (>0.2%) is the major limit of this system and leaves room for improvement. MC ICP-MS operated in the edge mass resolution mode, applying bracketing for correction of IIF, provided isotope ratio values with the highest quality (relative combined measurement uncertainty: 0.02%; deviation from the certified value: <0.002%).

  4. 42 CFR 421.122 - Performance standards.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... performance, application of acceptable statistical measures of variation to nationwide intermediary experience... or criterion. (b) Factors beyond intermediary's control. To identify measurable factors that significantly affect an intermediary's performance, but that are not within the intermediary's control, CMS will...

  5. 40 CFR 60.603 - Performance test and compliance provisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for... Solvent Contained in the Solvent Feed Holding Tank. (ii) Measure and record the amount of polymer introduced into the affected facility and the solvent-to-polymer ratio of the spinning solutions, and use the...

  6. Linear versus non-linear measures of temporal variability in finger tapping and their relation to performance on open- versus closed-loop motor tasks: comparing standard deviations to Lyapunov exponents.

    PubMed

    Christman, Stephen D; Weaver, Ryan

    2008-05-01

    The nature of temporal variability during speeded finger tapping was examined using linear (standard deviation) and non-linear (Lyapunov exponent) measures. Experiment 1 found that right hand tapping was characterised by lower amounts of both linear and non-linear measures of variability than left hand tapping, and that linear and non-linear measures of variability were often negatively correlated with one another. Experiment 2 found that increased non-linear variability was associated with relatively enhanced performance on a closed-loop motor task (mirror tracing) and relatively impaired performance on an open-loop motor task (pointing in a dark room), especially for left hand performance. The potential uses and significance of measures of non-linear variability are discussed.

  7. How Do You Measure That Ceramic Property?

    NASA Technical Reports Server (NTRS)

    Salem, Jonathan; Helfinstine, John; Quinn, George; Gonczy, Stephen

    2011-01-01

    By using the dozens of consensus test standards and practices developed by the Advanced Ceramics Committee of ASTM, C-28, the measurement of mechanical, physical, thermal, and performance properties can be properly performed. The what, how, how not, and why are clearly illustrated for beginning as well as experienced testers. Using these standards will provide accurate, reliable, and complete data for rigorous comparisons with other test results. The C-28 Committee has involved academics, and producers, and users of ceramics to write and continually update more than 45 standards since the committee's inception in 1986.

  8. Performance Measurement for Public Services in Academic and Research Libraries. Occasional Paper Number #9.

    ERIC Educational Resources Information Center

    Cronin, Mary J.

    This paper defines performance measurement as the clarification of objectives and standards, identification of key activities, data collection and analysis, and formative evaluation of services. It then examines some of the factors involved in using performance measurement to evaluate public services activities, and analyzes performance…

  9. Assessing technical performance in differential gene expression experiments with external spike-in RNA control ratio mixtures.

    PubMed

    Munro, Sarah A; Lund, Steven P; Pine, P Scott; Binder, Hans; Clevert, Djork-Arné; Conesa, Ana; Dopazo, Joaquin; Fasold, Mario; Hochreiter, Sepp; Hong, Huixiao; Jafari, Nadereh; Kreil, David P; Łabaj, Paweł P; Li, Sheng; Liao, Yang; Lin, Simon M; Meehan, Joseph; Mason, Christopher E; Santoyo-Lopez, Javier; Setterquist, Robert A; Shi, Leming; Shi, Wei; Smyth, Gordon K; Stralis-Pavese, Nancy; Su, Zhenqiang; Tong, Weida; Wang, Charles; Wang, Jian; Xu, Joshua; Ye, Zhan; Yang, Yong; Yu, Ying; Salit, Marc

    2014-09-25

    There is a critical need for standard approaches to assess, report and compare the technical performance of genome-scale differential gene expression experiments. Here we assess technical performance with a proposed standard 'dashboard' of metrics derived from analysis of external spike-in RNA control ratio mixtures. These control ratio mixtures with defined abundance ratios enable assessment of diagnostic performance of differentially expressed transcript lists, limit of detection of ratio (LODR) estimates and expression ratio variability and measurement bias. The performance metrics suite is applicable to analysis of a typical experiment, and here we also apply these metrics to evaluate technical performance among laboratories. An interlaboratory study using identical samples shared among 12 laboratories with three different measurement processes demonstrates generally consistent diagnostic power across 11 laboratories. Ratio measurement variability and bias are also comparable among laboratories for the same measurement process. We observe different biases for measurement processes using different mRNA-enrichment protocols.

  10. Recruitment of intuitive versus analytic thinking strategies affects the role of working memory in a gambling task.

    PubMed

    Gozzi, Marta; Cherubini, Paolo; Papagno, Costanza; Bricolo, Emanuela

    2011-05-01

    Previous studies found mixed results concerning the role of working memory (WM) in the gambling task (GT). Here, we aimed at reconciling inconsistencies by showing that the standard version of the task can be solved using intuitive strategies operating automatically, while more complex versions require analytic strategies drawing on executive functions. In Study 1, where good performance on the GT could be achieved using intuitive strategies, participants performed well both with and without a concurrent WM load. In Study 2, where analytical strategies were required to solve a more complex version of the GT, participants without WM load performed well, while participants with WM load performed poorly. In Study 3, where the complexity of the GT was further increased, participants in both conditions performed poorly. In addition to the standard performance measure, we used participants' subjective expected utility, showing that it differs from the standard measure in some important aspects.

  11. Pilot study: EatFit impacts sixth graders' academic performance on achievement of mathematics and english education standards.

    PubMed

    Shilts, Mical Kay; Lamp, Cathi; Horowitz, Marcel; Townsend, Marilyn S

    2009-01-01

    Investigate the impact of a nutrition education program on student academic performance as measured by achievement of education standards. Quasi-experimental crossover-controlled study. California Central Valley suburban elementary school (58% qualified for free or reduced-priced lunch). All sixth-grade students (n = 84) in the elementary school clustered in 3 classrooms. 9-lesson intervention with an emphasis on guided goal setting and driven by the Social Cognitive Theory. Multiple-choice survey assessing 5 education standards for sixth-grade mathematics and English at 3 time points: baseline (T1), 5 weeks (T2), and 10 weeks (T3). Repeated measures, paired t test, and analysis of covariance. Changes in total scores were statistically different (P < .05), with treatment scores (T3 - T2) generating more gains. The change scores for 1 English (P < .01) and 2 mathematics standards (P < .05; P < .001) were statistically greater for the treatment period (T3 - T2) compared to the control period (T2 - T1). Using standardized tests, results of this pilot study suggest that EatFit can improve academic performance measured by achievement of specific mathematics and English education standards. Nutrition educators can show school administrators and wellness committee members that this program can positively impact academic performance, concomitant to its primary objective of promoting healthful eating and physical activity.

  12. The Muon $g$-$2$ Experiment at Fermilab

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gohn, Wesley

    A new measurement of the anomalous magnetic moment of the muon,more » $$a_{\\mu} \\equiv (g-2)/2$$, will be performed at the Fermi National Accelerator Laboratory with data taking beginning in 2017. The most recent measurement, performed at Brookhaven National Laboratory (BNL) and completed in 2001, shows a 3.5 standard deviation discrepancy with the standard model value of $$a_\\mu$$. The new measurement will accumulate 21 times the BNL statistics using upgraded magnet, detector, and storage ring systems, enabling a measurement of $$a_\\mu$$ to 140 ppb, a factor of 4 improvement in the uncertainty the previous measurement. This improvement in precision, combined with recent improvements in our understanding of the QCD contributions to the muon $g$-$2$, could provide a discrepancy from the standard model greater than 7$$\\sigma$$ if the central value is the same as that measured by the BNL experiment, which would be a clear indication of new physics.« less

  13. A Measure of Failure: The Political Origins of Standardized Testing

    ERIC Educational Resources Information Center

    Garrison, Mark J.

    2009-01-01

    How did standardized tests become the measure of performance in our public schools? In this compelling work, Mark J. Garrison attempts to answer this question by analyzing the development of standardized testing, from the days of Horace Mann and Alfred Binet to the current scene. Approaching the issue from a sociohistorical perspective, the author…

  14. 40 CFR 230.95 - Ecological performance standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Ecological performance standards. 230.95 Section 230.95 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) OCEAN DUMPING... functional capacity described in functional assessment methodologies, measurements of hydrology or other...

  15. A Data Specification for Software Project Performance Measures: Results of a Collaboration on Performance Measurement

    DTIC Science & Technology

    2008-07-01

    cycle Evolution of a system, product, service, project or other human-made entity from conception through retirement [ ISO 12207 ]. Logical line of...012 [ ISO 1995] International Organization for Standardization. ISO /IEC 12207 :1995—Information technology— Software life cycle processes. http...definitions, authors were asked to use or align with already existing standards such as those available through ISO and IEEE when possible. Literature

  16. Development and Validation of a Clarinet Performance Adjudication Scale

    ERIC Educational Resources Information Center

    Abeles, Harold F.

    1973-01-01

    A basic assumption of this study is that there are generally agreed upon performance standards as evidenced by the use of adjudicators for evaluations at contests and festivals. An evaluation instrument was developed to enable raters to measure effectively those aspects of performance that have common standards of proficiency. (Author/RK)

  17. Assessing Outside the Bubble: Performance Assessment for Common Core State Standards

    ERIC Educational Resources Information Center

    Bishop, Jesica M.; Bristow, Lora J.; Coriell, Bryn P.; Jensen, Mark E.; Johnson, Leif E.; Luring, Sara R.; Lyons-Tinsley, Mary Ann; Mefford, Megan M.; Neu, Gwen L.; Samulski, Emerson T.; Warner, Timothy D.; White, Mathew F.

    2011-01-01

    The adoption of Common Core State Standards has increased the need for assessments capable of measuring more performance-based outcomes. This monograph brings together the current literature and resources for the development and implementation of performance assessment. The text was written as part of a project-based graduate course and has…

  18. The performance of single and multi-collector ICP-MS instruments for fast and reliable 34S/32S isotope ratio measurements†

    PubMed Central

    Pröfrock, Daniel; Irrgeher, Johanna; Prohaska, Thomas

    2016-01-01

    The performance and validation characteristics of different single collector inductively coupled plasma mass spectrometers based on different technical principles (ICP-SFMS, ICP-QMS in reaction and collision modes, and ICP-MS/MS) were evaluated in comparison to the performance of MC ICP-MS for fast and reliable S isotope ratio measurements. The validation included the determination of LOD, BEC, measurement repeatability, within-lab reproducibility and deviation from certified values as well as a study on instrumental isotopic fractionation (IIF) and the calculation of the combined standard measurement uncertainty. Different approaches of correction for IIF applying external intra-elemental IIF correction (aka standard-sample bracketing) using certified S reference materials and internal inter-elemental IIF (aka internal standardization) correction using Si isotope ratios in MC ICP-MS are explained and compared. The resulting combined standard uncertainties of examined ICP-QMS systems were not better than 0.3–0.5% (uc,rel), which is in general insufficient to differentiate natural S isotope variations. Although the performance of the single collector ICP-SFMS is better (single measurement uc,rel = 0.08%), the measurement reproducibility (>0.2%) is the major limit of this system and leaves room for improvement. MC ICP-MS operated in the edge mass resolution mode, applying bracketing for correction of IIF, provided isotope ratio values with the highest quality (relative combined measurement uncertainty: 0.02%; deviation from the certified value: <0.002%). PMID:27812369

  19. The application of robotics to microlaryngeal laser surgery.

    PubMed

    Buckmire, Robert A; Wong, Yu-Tung; Deal, Allison M

    2015-06-01

    To evaluate the performance of human subjects, using a prototype robotic micromanipulator controller in a simulated, microlaryngeal operative setting. Observational cross-sectional study. Twenty-two human subjects with varying degrees of laser experience performed CO2 laser surgical tasks within a simulated microlaryngeal operative setting using an industry standard manual micromanipulator (MMM) and a prototype robotic micromanipulator controller (RMC). Accuracy, repeatability, and ablation consistency measures were obtained for each human subject across both conditions and for the preprogrammed RMC device. Using the standard MMM, surgeons with >10 previous laser cases performed superior to subjects with fewer cases on measures of error percentage and cumulative error (P = .045 and .03, respectively). No significant differences in performance were observed between subjects using the RMC device. In the programmed (P/A) mode, the RMC performed equivalently or superiorly to experienced human subjects on accuracy and repeatability measures, and nearly an order of magnitude better on measures of ablation consistency. The programmed RMC performed significantly better for repetition error when compared to human subjects with <100 previous laser cases (P = .04). Experienced laser surgeons perform better than novice surgeons on tasks of accuracy and repeatability using the MMM device but roughly equivalently using the novel RMC. Operated in the P/A mode, the RMC performs equivalently or superior to experienced laser surgeons using the industry standard MMM for all measured parameters, and delivers an ablation consistency nearly an order of magnitude better than human laser operators. NA. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  20. Transportation performance measures for outcome based system management and monitoring.

    DOT National Transportation Integrated Search

    2014-09-01

    The Oregon Department of Transportation (ODOT) is mature in its development and use of : performance measures, however there was not a standard approach for selecting measures nor : evaluating if existing ones were used to inform decision-making. Thi...

  1. Society for Academic Continuing Medical Education Intervention Guideline Series: Guideline 1, Performance Measurement and Feedback.

    PubMed

    Van Hoof, Thomas J; Grant, Rachel E; Miller, Nicole E; Bell, Mary; Campbell, Craig; Colburn, Lois; Davis, David; Dorman, Todd; Horsley, Tanya; Jacobs-Halsey, Virginia; Kane, Gabrielle; LeBlanc, Constance; Lockyer, Jocelyn; Moore, Donald E; Morrow, Robert; Olson, Curtis A; Silver, Ivan; Thomas, David C; Kitto, Simon

    2015-01-01

    The Society for Academic Continuing Medical Education commissioned a study to clarify and, if possible, to standardize the terminology for a set of important educational interventions. In the form of a guideline, this article describes one such intervention, performance measurement and feedback, which is a common intervention in health professions education. In the form of a summary report, performance measurement and feedback is an opportunity for clinicians to view data about the care they provide compared with some standard and often with peer and benchmark comparisons. Based on a review of recent evidence and a facilitated discussion with the US and Canadian experts, we describe proper terminology for performance measurement and feedback and other important information about the intervention. We encourage leaders and researchers to consider and build on this guideline as they plan, implement, evaluate, and report efforts with performance measurement and feedback. Clear and consistent use of terminology is imperative, along with complete and accurate descriptions of interventions, to improve the use and study of performance measurement and feedback.

  2. PET Timing Performance Measurement Method Using NEMA NEC Phantom

    NASA Astrophysics Data System (ADS)

    Wang, Gin-Chung; Li, Xiaoli; Niu, Xiaofeng; Du, Huini; Balakrishnan, Karthik; Ye, Hongwei; Burr, Kent

    2016-06-01

    When comparing the performance of time-of-flight whole-body PET scanners, timing resolution is one important benchmark. Timing performance is heavily influenced by detector and electronics design. Even for the same scanner design, measured timing resolution is a function of many factors including the activity concentration, geometry and positioning of the radioactive source. Due to lack of measurement standards, the timing resolutions reported in the literature may not be directly comparable and may not describe the timing performance under clinically relevant conditions. In this work we introduce a method which makes use of the data acquired during the standard NEMA Noise-Equivalent-Count-Rate (NECR) measurements, and compare it to several other timing resolution measurement methods. The use of the NEMA NEC phantom, with well-defined dimensions and radioactivity distribution, is attractive because it has been widely accepted in the industry and allows for the characterization of timing resolution across a more relevant range of conditions.

  3. [Assessment comparison between area sampling and personal sampling noise measurement in new thermal power plant].

    PubMed

    Zhang, Hua; Chen, Qing-song; Li, Nan; Hua, Yan; Zeng, Lin; Xu, Guo-yang; Tao, Li-yuan; Zhao, Yi-ming

    2013-05-01

    To compare the results of noise hazard evaluations based on area sampling and personal sampling in a new thermal power plant and to analyze the similarities and differences between the two measurement methods. According to Measurement of Physical agents in Workplace Part 8: Noise(GBZff 189.8-2007), area sampling was performed at various operating points for noise measurement, and meanwhile the workers under different types of work wore noise dosimeters for personal noise exposure measurement. The two measurement methods were used to evaluate the level of noise hazards in the enterprise according to the corresponding occupational health standards, and the evaluation results were compared. Area sampling was performed at 99 operating points, the mean noise level was 88.9 ± 11.1 dB (A)(range, 51.3-107.0 dB (A)), with an over-standard rate of 75.8%. Personal sampling was performed (73 person times),and the mean noise level was 79.3 ± 6.3 dB (A), with an over-standard rate of 6.6% ( 16/241 ). There was a statistically significant difference in the over-standard rate between the evaluation results of the two measurement methods ( x2=53.869, ?<0.001 ). Because of the characteristics of the work in new thermal power plants, the noise hazard evaluation based on area sampling cannot be used instead of personal noise exposure measurement among workers. Personal sampling should be used in the noise measurement in new thermal power plant.

  4. 40 CFR 60.1390 - What are the appropriate units of measurement for reporting my data?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... measurement for reporting my data? 60.1390 Section 60.1390 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards... § 60.1390 What are the appropriate units of measurement for reporting my data? See tables 1 and 2 of...

  5. Testing the performance of dosimetry measurement standards for calibrating area and personnel dosimeters

    NASA Astrophysics Data System (ADS)

    Walwyn-Salas, G.; Czap, L.; Gomola, I.; Tamayo-García, J. A.

    2016-07-01

    The cylindrical NE2575 and spherical PTW32002 chamber types were tested in this paper to determine their performance at different source-chamber distances, field sizes and two radiation qualities. To ensure an accurate measurement, there is a need to apply a correction factor to NE2575 measurements at different distances because of differences found between the reference point defined by the manufacturer and the effective point of measurements. This correction factor for NE2575 secondary standard from the Center for Radiation Protection and Hygiene of Cuba was assessed with a 0.3% uncertainty using the results of three methods. Those laboratories that use the NE2575 chambers should take into consideration the performance characteristics tested in this paper to obtain accurate measurements.

  6. Hearing Aid–Related Standards and Test Systems

    PubMed Central

    Ravn, Gert; Preves, David

    2015-01-01

    Many documents describe standardized methods and standard equipment requirements in the field of audiology and hearing aids. These standards will ensure a uniform level and a high quality of both the methods and equipment used in audiological work. The standards create the basis for measuring performance in a reproducible manner and independent from how and when and by whom parameters have been measured. This article explains, and focuses on, relevant acoustic and electromagnetic compatibility parameters and describes several test systems available. PMID:27516709

  7. Indicators of Program Quality, Measures of Performance & Standards. Adult Basic Education and ESL Programs in NJ. Summary Report.

    ERIC Educational Resources Information Center

    Merkel-Keller, Claudia; Streeter-Scrupski, Sandra

    In 1992, adult education staff and adult literacy volunteer organizations developed 8 indicators of program quality to be used for evaluating adult basic education and English as a Second Language (ESL) programs in New Jersey. Performance standards were developed to match the standards. An evaluation was conducted to determine how the indicators…

  8. The Society of Thoracic Surgeons Composite Measure of Individual Surgeon Performance for Adult Cardiac Surgery: A Report of The Society of Thoracic Surgeons Quality Measurement Task Force.

    PubMed

    Shahian, David M; He, Xia; Jacobs, Jeffrey P; Kurlansky, Paul A; Badhwar, Vinay; Cleveland, Joseph C; Fazzalari, Frank L; Filardo, Giovanni; Normand, Sharon-Lise T; Furnary, Anthony P; Magee, Mitchell J; Rankin, J Scott; Welke, Karl F; Han, Jane; O'Brien, Sean M

    2015-10-01

    Previous composite performance measures of The Society of Thoracic Surgeons (STS) were estimated at the STS participant level, typically a hospital or group practice. The STS Quality Measurement Task Force has now developed a multiprocedural, multidimensional composite measure suitable for estimating the performance of individual surgeons. The development sample from the STS National Database included 621,489 isolated coronary artery bypass grafting procedures, isolated aortic valve replacement, aortic valve replacement plus coronary artery bypass grafting, mitral, or mitral plus coronary artery bypass grafting procedures performed by 2,286 surgeons between July 1, 2011, and June 30, 2014. Each surgeon's composite score combined their aggregate risk-adjusted mortality and major morbidity rates (each weighted inversely by their standard deviations) and reflected the proportion of case types they performed. Model parameters were estimated in a Bayesian framework. Composite star ratings were examined using 90%, 95%, or 98% Bayesian credible intervals. Measure reliability was estimated using various 3-year case thresholds. The final composite measure was defined as 0.81 × (1 minus risk-standardized mortality rate) + 0.19 × (1 minus risk-standardized complication rate). Risk-adjusted mortality (median, 2.3%; interquartile range, 1.7% to 3.0%), morbidity (median, 13.7%; interquartile range, 10.8% to 17.1%), and composite scores (median, 95.4%; interquartile range, 94.4% to 96.3%) varied substantially across surgeons. Using 98% Bayesian credible intervals, there were 207 1-star (lower performance) surgeons (9.1%), 1,701 2-star (as-expected performance) surgeons (74.4%), and 378 3-star (higher performance) surgeons (16.5%). With an eligibility threshold of 100 cases over 3 years, measure reliability was 0.81. The STS has developed a multiprocedural composite measure suitable for evaluating performance at the individual surgeon level. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Quantifying usability: an evaluation of a diabetes mHealth system on effectiveness, efficiency, and satisfaction metrics with associated user characteristics.

    PubMed

    Georgsson, Mattias; Staggers, Nancy

    2016-01-01

    Mobile health (mHealth) systems are becoming more common for chronic disease management, but usability studies are still needed on patients' perspectives and mHealth interaction performance. This deficiency is addressed by our quantitative usability study of a mHealth diabetes system evaluating patients' task performance, satisfaction, and the relationship of these measures to user characteristics. We used metrics in the International Organization for Standardization (ISO) 9241-11 standard. After standardized training, 10 patients performed representative tasks and were assessed on individual task success, errors, efficiency (time on task), satisfaction (System Usability Scale [SUS]) and user characteristics. Tasks of exporting and correcting values proved the most difficult, had the most errors, the lowest task success rates, and consumed the longest times on task. The average SUS satisfaction score was 80.5, indicating good but not excellent system usability. Data trends showed males were more successful in task completion, and younger participants had higher performance scores. Educational level did not influence performance, but a more recent diabetes diagnosis did. Patients with more experience in information technology (IT) also had higher performance rates. Difficult task performance indicated areas for redesign. Our methods can assist others in identifying areas in need of improvement. Data about user background and IT skills also showed how user characteristics influence performance and can provide future considerations for targeted mHealth designs. Using the ISO 9241-11 usability standard, the SUS instrument for satisfaction and measuring user characteristics provided objective measures of patients' experienced usability. These could serve as an exemplar for standardized, quantitative methods for usability studies on mHealth systems. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association.

  10. Quantifying usability: an evaluation of a diabetes mHealth system on effectiveness, efficiency, and satisfaction metrics with associated user characteristics

    PubMed Central

    Staggers, Nancy

    2016-01-01

    Objective Mobile health (mHealth) systems are becoming more common for chronic disease management, but usability studies are still needed on patients’ perspectives and mHealth interaction performance. This deficiency is addressed by our quantitative usability study of a mHealth diabetes system evaluating patients’ task performance, satisfaction, and the relationship of these measures to user characteristics. Materials and Methods We used metrics in the International Organization for Standardization (ISO) 9241-11 standard. After standardized training, 10 patients performed representative tasks and were assessed on individual task success, errors, efficiency (time on task), satisfaction (System Usability Scale [SUS]) and user characteristics. Results Tasks of exporting and correcting values proved the most difficult, had the most errors, the lowest task success rates, and consumed the longest times on task. The average SUS satisfaction score was 80.5, indicating good but not excellent system usability. Data trends showed males were more successful in task completion, and younger participants had higher performance scores. Educational level did not influence performance, but a more recent diabetes diagnosis did. Patients with more experience in information technology (IT) also had higher performance rates. Discussion Difficult task performance indicated areas for redesign. Our methods can assist others in identifying areas in need of improvement. Data about user background and IT skills also showed how user characteristics influence performance and can provide future considerations for targeted mHealth designs. Conclusion Using the ISO 9241-11 usability standard, the SUS instrument for satisfaction and measuring user characteristics provided objective measures of patients’ experienced usability. These could serve as an exemplar for standardized, quantitative methods for usability studies on mHealth systems. PMID:26377990

  11. International Standards for Properties and Performance of Advanced Ceramics - 30 years of Excellence

    NASA Technical Reports Server (NTRS)

    Jenkins, Michael G.; Salem, Jonathan A.; Helfinstine, John; Quinn, George D.; Gonczy, Stephen T.

    2016-01-01

    Mechanical and physical properties/performance of brittle bodies (e.g., advanced ceramics and glasses) can be difficult to measure correctly unless the proper techniques are used. For three decades, ASTM Committee C28 on Advanced Ceramics, has developed numerous full-consensus standards (e.g., test methods, practices, guides, terminology) to measure various properties and performance of a monolithic and composite ceramics and coatings that, in some cases, may be applicable to glasses. These standards give the "what, how, how not, why, why not, etc." for many mechanical, physical, thermal, properties and performance of advanced ceramics. Use of these standards provides accurate, reliable, repeatable and complete data. Involvement in ASTM Committee C28 has included users, producers, researchers, designers, academicians, etc. who write, continually update, and validate through round robin test programmes, more than 45 standards in the 30 years since the Committee's inception in 1986. Included in this poster is a pictogram of the ASTM Committee C28 standards and how to obtain them either as i) individual copies with full details or ii) a complete collection in one volume. A listing of other ASTM committees of interest is included. In addition, some examples of the tangible benefits of standards for advanced ceramics are employed to demonstrate their practical application.

  12. Setting performance standards for medical practice: a theoretical framework.

    PubMed

    Southgate, L; Hays, R B; Norcini, J; Mulholland, H; Ayers, B; Woolliscroft, J; Cusimano, M; McAvoy, P; Ainsworth, M; Haist, S; Campbell, M

    2001-05-01

    The assessment of performance in the real world of medical practice is now widely accepted as the goal of assessment at the postgraduate level. This is largely a validity issue, as it is recognised that tests of knowledge and in clinical simulations cannot on their own really measure how medical practitioners function in the broader health care system. However, the development of standards for performance-based assessment is not as well understood as in competency assessment, where simulations can more readily reflect narrower issues of knowledge and skills. This paper proposes a theoretical framework for the development of standards that reflect the more complex world in which experienced medical practitioners work. The paper reflects the combined experiences of a group of education researchers and the results of literature searches that included identifying current health system data sources that might contribute information to the measurement of standards. Standards that reflect the complexity of medical practice may best be developed through an "expert systems" analysis of clinical conditions for which desired health care outcomes reflect the contribution of several health professionals within a complex, three-dimensional, contextual model. Examples of the model are provided, but further work is needed to test validity and measurability.

  13. Dual Standards of School Performance and Funding? Empirical Searches of School Funding Adequacy in Kentucky and Maine

    ERIC Educational Resources Information Center

    Lee, Jaekyung

    2010-01-01

    This study examines potential consequences of the discrepancies between national and state performance standards for school funding in Kentucky and Maine. Applying the successful schools observation method and cost function analysis method to integrated data-sets that match schools' eight-grade mathematics test performance measures to district…

  14. Fabrication of 12% {sup 240}Pu calorimetry standards

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Long, S.M.; Hildner, S.; Gutierrez, D.

    1995-08-01

    Throughout the DOE complex, laboratories are performing calorimetric assays on items containing high burnup plutonium. These materials contain higher isotopic range and higher wattages than materials previously encountered in vault holdings. Currently, measurement control standards have been limited to utilizing 6% {sup 240}Pu standards. The lower isotopic and wattage value standards do not complement the measurement of the higher burnup material. Participants of the Calorimetry Exchange (CALEX) Program have identified the need for new calorimetric assay standards with a higher wattage and isotopic range. This paper describes the fabrication and verification measurements of the new CALEX standard containing 12% {supmore » 240}Pu oxide with a wattage of about 6 to 8 watts.« less

  15. Body composition and military performance--many things to many people.

    PubMed

    Friedl, Karl E

    2012-07-01

    Soldiers are expected to maintain the highest possible level of physical readiness because they must be ready to mobilize and perform their duties anywhere in the world at any time. The objective of Army body composition standards is to motivate physical training and good nutrition habits to ensure a high state of readiness. Establishment of enforceable and rational standards to support this objective has been challenging even at extremes of body size. Morbidly obese individuals are clearly not suited to military service, but very large muscular individuals may be superbly qualified for soldier performance demands. For this reason, large individuals are measured for body fat using a waist circumference-based equation (female soldiers are also measured for hip circumference). The main challenge comes in setting appropriate fat standards to support the full range of Army requirements. Military appearance ideals dictate the most stringent body fat standards, whereas health risk thresholds anchor the most liberal standards, and physical performance associations fall on a spectrum between these 2 poles. Standards should not exclude or penalize specialized performance capabilities such as endurance running or power lifting across a spectrum of body sizes and fat. The full integration of women into the military further complicates the issue because of sexually dimorphic characteristics that make gender-appropriate standards essential and where inappropriately stringent standards can compromise both health and performance of this segment of the force. Other associations with body composition such as stress effects on intraabdominal fat distribution patterns and metabolic implications of a fat reserve for survival in extreme environments are also relevant considerations. This is a review of the science that underpins the U.S. Army body composition standards.

  16. The density-salinity relation of standard seawater

    NASA Astrophysics Data System (ADS)

    Schmidt, Hannes; Seitz, Steffen; Hassel, Egon; Wolf, Henning

    2018-01-01

    The determination of salinity by means of electrical conductivity relies on stable salt proportions in the North Atlantic Ocean, because standard seawater, which is required for salinometer calibration, is produced from water of the North Atlantic. To verify the long-term stability of the standard seawater composition, it was proposed to perform measurements of the standard seawater density. Since the density is sensitive to all salt components, a density measurement can detect any change in the composition. A conversion of the density values to salinity can be performed by means of a density-salinity relation. To use such a relation with a target uncertainty in salinity comparable to that in salinity obtained from conductivity measurements, a density measurement with an uncertainty of 2 g m-3 is mandatory. We present a new density-salinity relation based on such accurate density measurements. The substitution measurement method used is described and density corrections for uniform isotopic and chemical compositions are reported. The comparison of densities calculated using the new relation with those calculated using the present reference equations of state TEOS-10 suggests that the density accuracy of TEOS-10 (as well as that of EOS-80) has been overestimated, as the accuracy of some of its underlying density measurements had been overestimated. The new density-salinity relation may be used to verify the stable composition of standard seawater by means of routine density measurements.

  17. C (G)-Band & X (I) - Band Noncoherent Radar Transponder Performance Specification Standard

    DTIC Science & Technology

    2002-04-01

    TRAINING RANGE NEVADA TEST SITE STANDARD 262-02 ELECTRONIC TRAJECTORY MEASUREMENTS GROUP C (G) – BAND & X (I) – BAND NONCOHERENT RADAR...Date 00 Apr 2002 Report Type N/A Dates Covered (from... to) - Title and Subtitle C (G)-Band & X (I) - Band Noncoherent Radar Transponder...Number of Pages 157 i STANDARD 262-02 C (G) – BAND & X (I) – BAND NONCOHERENT RADAR TRANSPONDER PERFORMANCE SPECIFICATION STANDARD APRIL 2002 Prepared by

  18. 34 CFR 403.202 - What must each State's system of core standards and measures of performance include?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... academic skills; (2) One or more measures of the following: (i) Student competency attainment. (ii) Job or... skills in the industry the student is preparing to enter. (iii) Retention in school or completion of... appropriate, for consistency with— (1) Standards and measures developed under job opportunities and basic...

  19. Student Performances in Various Learning Protocols

    ERIC Educational Resources Information Center

    Gregorius, Roberto

    2011-01-01

    A comparison was made between students' overall performance, as measured by overall grade, in different teaching and learning protocols: (1) traditional textbook and lecture along with standard examinations; (2) lectures with online augmentation and PowerPoint lecture notes along with standard examinations; (3) similar to "(2)" but with…

  20. Composite Reliability and Standard Errors of Measurement for a Seven-Subtest Short Form of the Wechsler Adult Intelligence Scale-Revised.

    ERIC Educational Resources Information Center

    Schretlen, David; And Others

    1994-01-01

    Composite reliability and standard errors of measurement were computed for prorated Verbal, Performance, and Full-Scale intelligence quotient (IQ) scores from a seven-subtest short form of the Wechsler Adult Intelligence Scale-Revised. Results with 1,880 adults (standardization sample) indicate that this form is as reliable as the complete test.…

  1. Validity of a verbal incidental learning measure from the WAIS-IV in older adults.

    PubMed

    Hammers, Dustin B; Kucera, Amanda M; Card, Stephanie J; Tolle, Kathryn A; Atkinson, Taylor J; Duff, Kevin; Spencer, Robert J

    2018-01-01

    Incidental memory may reflect a form of learning in everyday life, although it is not consistently evaluated during standard neuropsychological evaluations. Further validation of a recently created measure of verbal Incidental Learning (IL) from the Wechsler Adult Intelligence Scale-IV is necessary to understand the utility of such a measure in clinical settings. Sixty-eight adults aged 50 to 89 were recruited from a Cognitive Disorders Clinic while receiving a standard neuropsychological assessment, along with two additional measures of IL. IL-Total Score was significantly correlated with immediate and delayed memory trials from standard neuropsychological tests (rs = .43 to .73, ps < .001, ds = 0.94-2.14), with worse IL performance being associated with lower memory abilities. Participants with probable Alzheimer's disease performed worse on the IL-Total Score than participants with Mild Cognitive Impairment, t(39.997) = 5.46, p < .001, d = 1.13. Given the strong relationships between this IL task and traditional memory measures in our sample, and the discrimination of IL-Total Score performance among diagnostic groups despite its short administration time, this IL task may play a role as a measure of memory in brief cognitive evaluations.

  2. Measures of rowing performance.

    PubMed

    Smith, T Brett; Hopkins, Will G

    2012-04-01

    Accurate measures of performance are important for assessing competitive athletes in practi~al and research settings. We present here a review of rowing performance measures, focusing on the errors in these measures and the implications for testing rowers. The yardstick for assessing error in a performance measure is the random variation (typical or standard error of measurement) in an elite athlete's competitive performance from race to race: ∼1.0% for time in 2000 m rowing events. There has been little research interest in on-water time trials for assessing rowing performance, owing to logistic difficulties and environmental perturbations in performance time with such tests. Mobile ergometry via instrumented oars or rowlocks should reduce these problems, but the associated errors have not yet been reported. Measurement of boat speed to monitor on-water training performance is common; one device based on global positioning system (GPS) technology contributes negligible extra random error (0.2%) in speed measured over 2000 m, but extra error is substantial (1-10%) with other GPS devices or with an impeller, especially over shorter distances. The problems with on-water testing have led to widespread use of the Concept II rowing ergometer. The standard error of the estimate of on-water 2000 m time predicted by 2000 m ergometer performance was 2.6% and 7.2% in two studies, reflecting different effects of skill, body mass and environment in on-water versus ergometer performance. However, well trained rowers have a typical error in performance time of only ∼0.5% between repeated 2000 m time trials on this ergometer, so such trials are suitable for tracking changes in physiological performance and factors affecting it. Many researchers have used the 2000 m ergometer performance time as a criterion to identify other predictors of rowing performance. Standard errors of the estimate vary widely between studies even for the same predictor, but the lowest errors (~1-2%) have been observed for peak power output in an incremental test, some measures of lactate threshold and measures of 30-second all-out power. Some of these measures also have typical error between repeated tests suitably low for tracking changes. Combining measures via multiple linear regression needs further investigation. In summary, measurement of boat speed, especially with a good GPS device, has adequate precision for monitoring training performance, but adjustment for environmental effects needs to be investigated. Time trials on the Concept II ergometer provide accurate estimates of a rower's physiological ability to output power, and some submaximal and brief maximal ergometer performance measures can be used frequently to monitor changes in this ability. On-water performance measured via instrumented skiffs that determine individual power output may eventually surpass measures derived from the Concept II.

  3. Validation of GC and HPLC systems for residue studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, M.

    1995-12-01

    For residue studies, GC and HPLC system performance must be validated prior to and during use. One excellent measure of system performance is the standard curve and associated chromatograms used to construct that curve. The standard curve is a model of system response to an analyte over a specific time period, and is prima facia evidence of system performance beginning at the auto sampler and proceeding through the injector, column, detector, electronics, data-capture device, and printer/plotter. This tool measures the performance of the entire chromatographic system; its power negates most of the benefits associated with costly and time-consuming validation ofmore » individual system components. Other measures of instrument and method validation will be discussed, including quality control charts and experimental designs for method validation.« less

  4. Handbook of Human Performance Measures and Crew Requirements for Flight Deck Research

    DOT National Transportation Integrated Search

    1995-12-01

    The Federal Aviation Administration (FAA) Technical Center envisions that their : studies will require standard measure of pilot/crew performance. Therefore, : the FAA commissioned the Crew System Ergonomics Information Analysis Center : (CSERIAC) to...

  5. Development of a Primary Standard for Calibration of [18F]FDG Activity Measurement Systems

    NASA Astrophysics Data System (ADS)

    Capogni, M.; DeFelice, P.; Fazio, A.; Simonelli, F.; D'Ursi, V.; Pecorale, A.; Giliberti, C.; Abbas, K.

    2006-05-01

    The 18F national primary standard was developed by the INMRI-ENEA using the 4πβ Liquid Scintillation Spectrometry Method with 3H-Standard Efficiency Tracing. Measurements were performed at JRCIspra under a scientific collaboration between the Institute for Health and Consumer Production, the Amersham Health and the National Institute for Occupational Safety and Prevention (ISPESL). The goal of the work was to calibrate, with minimum uncertainty, the INMRI-ENEA transfer standard portable well-type ionisation chamber as well as other JRC-Ispra and Amersham Health reference Ionising Chambers used for FDG activity measurement.

  6. Validity of maximal isometric knee extension strength measurements obtained via belt-stabilized hand-held dynamometry in healthy adults.

    PubMed

    Ushiyama, Naoko; Kurobe, Yasushi; Momose, Kimito

    2017-11-01

    [Purpose] To determine the validity of knee extension muscle strength measurements using belt-stabilized hand-held dynamometry with and without body stabilization compared with the gold standard isokinetic dynamometry in healthy adults. [Subjects and Methods] Twenty-nine healthy adults (mean age, 21.3 years) were included. Study parameters involved right side measurements of maximal isometric knee extension strength obtained using belt-stabilized hand-held dynamometry with and without body stabilization and the gold standard. Measurements were performed in all subjects. [Results] A moderate correlation and fixed bias were found between measurements obtained using belt-stabilized hand-held dynamometry with body stabilization and the gold standard. No significant correlation and proportional bias were found between measurements obtained using belt-stabilized hand-held dynamometry without body stabilization and the gold standard. The strength identified using belt-stabilized hand-held dynamometry with body stabilization may not be commensurate with the maximum strength individuals can generate; however, it reflects such strength. In contrast, the strength identified using belt-stabilized hand-held dynamometry without body stabilization does not reflect the maximum strength. Therefore, a chair should be used to stabilize the body when performing measurements of maximal isometric knee extension strength using belt-stabilized hand-held dynamometry in healthy adults. [Conclusion] Belt-stabilized hand-held dynamometry with body stabilization is more convenient than the gold standard in clinical settings.

  7. Potential Predictors of Student Teaching Performance: Considering Emotional Intelligence

    ERIC Educational Resources Information Center

    Hall, P. Cougar; West, Joshua H.

    2011-01-01

    Efforts to increase teacher quality have focused on increasing both the admission and graduation standards required for students entering the profession. This study examined the relationship between common standards, such as college GPA, ACT scores, and Praxis exam scores, with student teacher performance as measured by an assessment rubric based…

  8. Expansion of CMOS array design techniques

    NASA Technical Reports Server (NTRS)

    Feller, A.; Ramondetta, P.

    1977-01-01

    The important features of the multiport (double entry) automatic placement and routing programs for standard cells are described. Measured performance and predicted performance were compared for seven CMOS/SOS array types and hybrids designed with the high speed CMOS/SOS cell family. The CMOS/SOS standard cell data sheets are listed and described.

  9. Performance standards for pass-fail determinations in the national air traffic flight service station training program.

    DOT National Transportation Integrated Search

    1979-07-01

    This report describes and documents Pass-Fail procedures for the new FSS Training Program. New types of measures and sets of norms are used to create standards of performance that students must meet to become eligible for acceptance into the operatio...

  10. Applying Standards for Leaders to the Selection of Secondary School Principals

    ERIC Educational Resources Information Center

    Wildy, Helen; Pepper, Coral; Guanzhong, Luo

    2011-01-01

    Purpose: The purpose of this paper is to report innovative research aimed at ascertaining whether standards for school leaders could be applied to the process of selecting senior secondary school principals for appointment. Specifically, psychometrically robust measures of performance are sought that would sufficiently differentiate performance to…

  11. 45 CFR 305.62 - Disregard of a failure which is of a technical nature.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., DEPARTMENT OF HEALTH AND HUMAN SERVICES PROGRAM PERFORMANCE MEASURES, STANDARDS, FINANCIAL INCENTIVES, AND... adversely affect the performance of the State's IV-D program or does not adversely affect the determination of the level of the State's paternity establishment or other performance measures percentages. ...

  12. Using Performance Assessments To Measure Teachers' Competence in Classroom Assessment.

    ERIC Educational Resources Information Center

    O'Sullivan, Rita G.; Johnson, Robert L.

    The development and pilot testing of a set of performance assessments to determine classroom teachers' measurement competencies in areas covered by "Standards for Teacher Competence in Educational Assessment of Students" (1990) are described. How the use of performance assessments in a graduate-level classroom-assessment course can…

  13. Shifting Gears: Standards, Assessments, Curriculum, & Instruction.

    ERIC Educational Resources Information Center

    Dougherty, Eleanor

    This book is designed to help educators move from a system that measures students against students to one that values mastery of central concepts and skills, striving for proficiency in publicly acknowledged standards of academic performance. It aims to connect the operative parts of standards-based education (standards, assessment, curriculum,…

  14. The State's Formula for Success 2006

    ERIC Educational Resources Information Center

    Colorado Department of Education, 2006

    2006-01-01

    This standards review is the second in a series of annual reviews of the Colorado Model Content Standards. Its purpose is to identify student performance over time on measures of existing science standards, identify ways to affirm and strengthen standards and more clearly articulate the practices used by Colorado schools to promote student…

  15. Prediction models for clustered data: comparison of a random intercept and standard regression model

    PubMed Central

    2013-01-01

    Background When study data are clustered, standard regression analysis is considered inappropriate and analytical techniques for clustered data need to be used. For prediction research in which the interest of predictor effects is on the patient level, random effect regression models are probably preferred over standard regression analysis. It is well known that the random effect parameter estimates and the standard logistic regression parameter estimates are different. Here, we compared random effect and standard logistic regression models for their ability to provide accurate predictions. Methods Using an empirical study on 1642 surgical patients at risk of postoperative nausea and vomiting, who were treated by one of 19 anesthesiologists (clusters), we developed prognostic models either with standard or random intercept logistic regression. External validity of these models was assessed in new patients from other anesthesiologists. We supported our results with simulation studies using intra-class correlation coefficients (ICC) of 5%, 15%, or 30%. Standard performance measures and measures adapted for the clustered data structure were estimated. Results The model developed with random effect analysis showed better discrimination than the standard approach, if the cluster effects were used for risk prediction (standard c-index of 0.69 versus 0.66). In the external validation set, both models showed similar discrimination (standard c-index 0.68 versus 0.67). The simulation study confirmed these results. For datasets with a high ICC (≥15%), model calibration was only adequate in external subjects, if the used performance measure assumed the same data structure as the model development method: standard calibration measures showed good calibration for the standard developed model, calibration measures adapting the clustered data structure showed good calibration for the prediction model with random intercept. Conclusion The models with random intercept discriminate better than the standard model only if the cluster effect is used for predictions. The prediction model with random intercept had good calibration within clusters. PMID:23414436

  16. Prediction models for clustered data: comparison of a random intercept and standard regression model.

    PubMed

    Bouwmeester, Walter; Twisk, Jos W R; Kappen, Teus H; van Klei, Wilton A; Moons, Karel G M; Vergouwe, Yvonne

    2013-02-15

    When study data are clustered, standard regression analysis is considered inappropriate and analytical techniques for clustered data need to be used. For prediction research in which the interest of predictor effects is on the patient level, random effect regression models are probably preferred over standard regression analysis. It is well known that the random effect parameter estimates and the standard logistic regression parameter estimates are different. Here, we compared random effect and standard logistic regression models for their ability to provide accurate predictions. Using an empirical study on 1642 surgical patients at risk of postoperative nausea and vomiting, who were treated by one of 19 anesthesiologists (clusters), we developed prognostic models either with standard or random intercept logistic regression. External validity of these models was assessed in new patients from other anesthesiologists. We supported our results with simulation studies using intra-class correlation coefficients (ICC) of 5%, 15%, or 30%. Standard performance measures and measures adapted for the clustered data structure were estimated. The model developed with random effect analysis showed better discrimination than the standard approach, if the cluster effects were used for risk prediction (standard c-index of 0.69 versus 0.66). In the external validation set, both models showed similar discrimination (standard c-index 0.68 versus 0.67). The simulation study confirmed these results. For datasets with a high ICC (≥15%), model calibration was only adequate in external subjects, if the used performance measure assumed the same data structure as the model development method: standard calibration measures showed good calibration for the standard developed model, calibration measures adapting the clustered data structure showed good calibration for the prediction model with random intercept. The models with random intercept discriminate better than the standard model only if the cluster effect is used for predictions. The prediction model with random intercept had good calibration within clusters.

  17. Evaluation of the measurement uncertainty when measuring the resistance of solid isolating materials to tracking

    NASA Astrophysics Data System (ADS)

    Stare, E.; Beges, G.; Drnovsek, J.

    2006-07-01

    This paper presents the results of research into the measurement of the resistance of solid isolating materials to tracking. Two types of tracking were investigated: the proof tracking index (PTI) and the comparative tracking index (CTI). Evaluation of the measurement uncertainty in a case study was performed using a test method in accordance with the IEC 60112 standard. In the scope of the tests performed here, this particular test method was used to ensure the safety of electrical appliances. According to the EN ISO/IEC 17025 standard (EN ISO/IEC 17025), in the process of conformity assessment, the evaluation of the measurement uncertainty of the test method should be carried out. In the present article, possible influential parameters that are in accordance with the third and fourth editions of the standard IEC 60112 are discussed. The differences, ambiguities or lack of guidance referring to both editions of the standard are described in the article 'Ambiguities in technical standards—case study IEC 60112—measuring the resistance of solid isolating materials to tracking' (submitted for publication). Several hundred measurements were taken in the present experiments in order to form the basis for the results and conclusions presented. A specific problem of the test (according to the IEC 60112 standard) is the great variety of influential physical parameters (mechanical, electrical, chemical, etc) that can affect the results. At the end of the present article therefore, there is a histogram containing information on the contributions to the measurement uncertainty.

  18. Fluid-flow-rate metrology: laboratory uncertainties and traceabilities

    NASA Astrophysics Data System (ADS)

    Mattingly, G. E.

    1991-03-01

    Increased concerns for improved fluid flowrate measurement are driving the fluid metering community-meter manufacturers and users alike-to search for better verification and documentation for their fluid measurements. These concerns affect both our domestic and international market places they permeate our technologies - aerospace chemical processes automotive bioengineering etc. They involve public health and safety and they impact our national defense. These concerns are based upon the rising value of fluid resources and products and the importance of critical material accountability. These values directly impact the accuracy needs of fluid buyers and sellers in custody transfers. These concerns impact the designers and operators of chemical process systems where control and productivity optimization depend critically upon measurement precision. Public health and safety depend upon the quality of numerous pollutant measurements - both liquid and gaseous. The performance testing of engines - both automotive and aircraft are critically based upon accurate fuel measurements - both liquid and oxidizer streams. Fluid flowrate measurements are established differently from counterparts in length and mass measurement systems because these have the benefits of " identity" standards. For rate measurement systems the metrology is based upon " derived standards" . These use facilities and transfer standards which are designed built characterized and used to constitute basic measurement capabilities and quantify performance - accuracy and precision. Because " identity standards" do not exist for flow measurements facsimiles or equivalents must

  19. Accurate method for luminous transmittance and signal detection quotients measurements in sunglasses lenses

    NASA Astrophysics Data System (ADS)

    Loureiro, A. D.; Gomes, L. M.; Ventura, L.

    2018-02-01

    The international standard ISO 12312-1 proposes transmittance tests that quantify how dark sunglasses lenses are and whether or not they are suitable for driving. To perform these tests a spectrometer is required. In this study, we present and analyze theoretically an accurate alternative method for performing these measurements using simple components. Using three LEDs and a four-channel sensor we generated weighting functions similar to the standard ones for luminous and traffic lights transmittances. From 89 sunglasses lens spectroscopy data, we calculated luminous transmittance and signal detection quotients using our obtained weighting functions and the standard ones. Mean-difference Tukey plots were used to compare the results. All tested sunglasses lenses were classified in the right category and correctly as suitable or not for driving. The greatest absolute errors for luminous transmittance and red, yellow, green and blue signal detection quotients were 0.15%, 0.17, 0.06, 0.04 and 0.18, respectively. This method will be used in a device capable to perform transmittance tests (visible, traffic lights and ultraviolet (UV)) according to the standard. It is important to measure rightly luminous transmittance and relative visual attenuation quotients to report correctly whether or not sunglasses are suitable for driving. Moreover, standard UV requirements depend on luminous transmittance.

  20. Determining radiated sound power of building structures by means of laser Doppler vibrometry

    NASA Astrophysics Data System (ADS)

    Roozen, N. B.; Labelle, L.; Rychtáriková, M.; Glorieux, C.

    2015-06-01

    This paper introduces a methodology that makes use of laser Doppler vibrometry to assess the acoustic insulation performance of a building element. The sound power radiated by the surface of the element is numerically determined from the vibrational pattern, offering an alternative for classical microphone measurements. Compared to the latter the proposed analysis is not sensitive to room acoustical effects. This allows the proposed methodology to be used at low frequencies, where the standardized microphone based approach suffers from a high uncertainty due to a low acoustic modal density. Standardized measurements as well as laser Doppler vibrometry measurements and computations have been performed on two test panels, a light-weight wall and a gypsum block wall and are compared and discussed in this paper. The proposed methodology offers an adequate solution for the assessment of the acoustic insulation of building elements at low frequencies. This is crucial in the framework of recent proposals of acoustic standards for measurement approaches and single number sound insulation performance ratings to take into account frequencies down to 50 Hz.

  1. Highlights of Conference on Using Student Test Scores to Measure Teacher Performance: The State of the Art in Research and Practice

    ERIC Educational Resources Information Center

    Guarino, Cassandra; Reckase, Mark D.; Wooldridge, Jeffrey M.

    2013-01-01

    The push for accountability in public schooling has extended to the measurement of teacher performance, accelerated by federal efforts through Race to the Top. Currently, a large number of states and districts across the country are computing measures of teacher performance based on the standardized test scores of their students and using them to…

  2. Pilot Study: EatFit Impacts Sixth Graders' Academic Performance on Achievement of Mathematics and English Education Standards

    ERIC Educational Resources Information Center

    Shilts, Mical Kay; Lamp, Cathi; Horowitz, Marcel; Townsend, Marilyn S.

    2009-01-01

    Objective: Investigate the impact of a nutrition education program on student academic performance as measured by achievement of education standards. Design: Quasi-experimental crossover-controlled study. Setting: California Central Valley suburban elementary school (58% qualified for free or reduced-priced lunch). Participants: All sixth-grade…

  3. Proposed Performance Standards for Comprehensive Support Services and Vocational Equity Grants.

    ERIC Educational Resources Information Center

    Lewis, Morgan V.

    Activities to develop proposed performance standards and measures for programs receiving funds authorized by the Carl D. Perkins Vocational and Applied Technology Education Act are described in this report. Two sections of the act are considered: Section 221 authorizes programs for single parents, displaced homemakers, and single pregnant women;…

  4. Science and Art of Setting Performance Standards and Cutoff Scores in Kinesiology

    ERIC Educational Resources Information Center

    Zhu, Weimo

    2013-01-01

    Setting standards and cutoff scores is essential to any measurement and evaluation practice. Two evaluation frameworks, norm-referenced (NR) and criterion-referenced (CR), have often been used for setting standards. Although setting fitness standards based on the NR evaluation is relatively easy as long as a nationally representative sample can be…

  5. Clinical and microperimetric predictors of reading speed in low vision patients: a structural equation modeling approach.

    PubMed

    Giacomelli, Giovanni; Virgili, Gianni; Giansanti, Fabrizio; Sato, Giovanni; Cappello, Ezio; Cruciani, Filippo; Varano, Monica; Menchini, Ugo

    2013-06-27

    To investigate the simultaneous association of several psychophysical measures with reading ability in patients with mild and moderate low vision attending rehabilitation services. Standard measurements of reading ability (Minnesota Reading [MNREAD] charts), visual acuity (Early Treatment of Diabetic Retinopathy Study [ETDRS] charts), contrast sensitivity (Pelli-Robson charts), reading contrast threshold (Reading Explorer [REX] charts), retinal sensitivity, and fixation stability and localization (Micro Perimeter 1 [MP1] fundus perimetry) were obtained in 160 low vision patients with better eye visual acuity ranging from 0.3 to 1.0 logarithm of the minimum angle of resolution and affected by either age-related macular degeneration or diabetic retinopathy. All variables were moderately associated with reading performance measures (MNREAD reading speed and reading acuity and REX reading contrast threshold), as well as among each other. In a structural equation model, REX reading contrast threshold was highly associated with MNREAD reading speed (standardized coefficient, 0.63) and moderately associated with reading acuity (standardized coefficient, -0.30). REX test also mediated the effects of Pelli-Robson contrast sensitivity (standardized coefficient, 0.44), MP1 fixation eccentricity (standardized coefficient, -0.19), and the mean retinal sensitivity (standardized coefficient, 0.23) on reading performance. The MP1 fixation stability was associated with both MNREAD reading acuity (standardized coefficient, -0.24) and MNREAD reading speed (standardized coefficient, 0.23), while ETDRS visual acuity only affected reading acuity (standardized coefficient, 0.44). Fixation instability and contrast sensitivity loss are key factors limiting reading performance of patients with mild or moderate low vision. REX charts directly assess the impact of text contrast on letter recognition and text navigation and may be a useful aid in reading rehabilitation.

  6. Advanced Ceramics Property Measurements

    NASA Technical Reports Server (NTRS)

    Salem, Jonathan; Helfinstine, John; Quinn, George; Gonczy, Stephen

    2013-01-01

    Mechanical and physical properties of ceramic bodies can be difficult to measure correctly unless the proper techniques are used. The Advanced Ceramics Committee of ASTM, C-28, has developed dozens of consensus test standards and practices to measure various properties of a ceramic monolith, composite, or coating. The standards give the "what, how, how not, and why" for measurement of many mechanical, physical, thermal, and performance properties. Using these standards will provide accurate, reliable, and complete data for rigorous comparisons with other test results from your test lab, or another. The C-28 Committee has involved academics, producers, and users of ceramics to write and continually update more than 45 standards since the committee's inception in 1986. Included in this poster is a pictogram of the C-28 standards and information on how to obtain individual copies with full details or the complete collection of standards in one volume.

  7. Comparison Between NIST and AF Laser Energy Standards Using High Power Lasers

    PubMed Central

    Li, Xiaoyu; Scott (Retired), Thomas; Cromer, Chris; Cooper, David; Comisford, Steven

    2007-01-01

    We report the results of a high-energy laser calorimeter comparison conducted by the National Institute of Standards and Technology (NIST), Boulder, Colorado and the U.S. Air Force Primary Standards laboratory (AFPSL), Heath, Ohio. A laser power meter, used as a transfer standard, was calibrated at each laboratory, sequentially, and the measurement results were compared. These measurements were performed at a nominal power of 800 W and a wavelength of 10.6 μm using CO2 lasers. Excellent measurement agreement (1.02 %) was demonstrated, which was well within each of the expanded uncertainties from the two laboratories involved in this comparison. PMID:27110471

  8. Toward a neurologic model of competency: Cognitive predictors of capacity to consent in Alzheimer's disease using three different legal standards.

    PubMed

    Marson, D C; Chatterjee, A; Ingram, K K; Harrell, L E

    1996-03-01

    To identify cognitive predictors of competency performance and status in Alzheimer's disease (AD) using three differentially stringent legal standards for capacity to consent. Univariate and multivariate analyses of independent neuropsychological test measures with three dependent measures of competency to consent to treatment. University medical center. 15 normal older controls and 29 patients with probably AD (15 mild and 14 moderate). Subjects were administered a batter of neuropsychological measures theoretically linked to competency function, as well as two clinical vignettes testing capacity to consent to medical treatment under five legal standards (LSs). The present study focused on three differentially stringent LSs: the capacity simply to "evidence a treatment of choice" (LS1), which is a minimal standard; the capacity to "appreciate the consequences" of a treatment of choice (LS3), a moderately stringent standard; and the capacity to "understand the treatment situation and choices" (LS5), the most stringent standard. Control subject and AD patient neuropsychological test scores were correlated with scores on the three LSs. The resulting univariate correlates were than analyzed using stepwise regression and discriminant function to identify key multivariate predictors of competency performance and status under each LS. No neuropsychological measures predicted control group performance on the LSs. For the AD group, a measure of simple auditory comprehension predicted LS1 performance (r(2)=0.44, p < 0.0001), a word fluency measure predicted LS3 performance (r(2)=0.58, p < 0.0001), and measures of conceptualization and confrontation naming together predicted LS5 performance (r(2)=0.81, p < 0.0001). Under discriminant function analysis, confrontation naming was the best single predictor of LS1 competency status for all subjects, correctly classifying 96% of cases (42/44). Measures of visumotor tracking and confrontation naming were the best single predictors, respectively, of competency status under LS3 (91% [39/43]) and LS5 (98% [43/44]). Multiple cognitive functions are associated with loss of competency in AD. Deficits in conceptualization, semantic memory, and probably verbal recall are associated with the declining capacity of mild AD patients to understand a treatment situation and choices (LS5); executive dysfunction with the declining capacity of mild to moderate AD patients to identify the consequences of treatment choice (LS3); and receptive aphasia and severe dysnomia with the declining capacity of advanced AD patients to evidence a simple treatment choice (LS1). The results offer insight into the relationship between different legal thresholds of competency and the progressive cognitive changes characteristic of AD, and represent an initial step toward a neurologic model of competency.

  9. Chlamydial partner notification in the British Association for Sexual Health and HIV (BASHH) 2011 UK national audit against the BASHH Medical Foundation for AIDS and Sexual Health Sexually Transmitted Infections Management Standards.

    PubMed

    McClean, H; Carne, C A; Sullivan, A K; Radcliffe, K W; Ahmed-Jushuf, I

    2012-10-01

    This paper reports on chlamydial partner notification (PN) performance in the 2011 BASHH national audit against the British Association for Sexual Health and HIV (BASHH) Medical Foundation for AIDS Sexual Health (MedFASH) Sexually Transmitted Infection Management Standards (STIMS). There was wide regional variation in level 3 clinic PN performance against the current standard of index case-reported chlamydial PN, with 43% (regional range 0-80%) of clinics outside London meeting the ≥0.6 contacts seen per index standard, and 85% of clinics (regional range 82-88%) in London meeting the ≥0.4 standard. For level 2 clinics, 39% (regional range 0-100%) of clinics outside London met the ≥0.6 standard, and 43% (regional range 40-50%) of clinics in London met the ≥0.4 standard. Performance for health-care worker (HCW)-verified contact attendance is also reported. New standards for each of these performance measures are proposed for all level 3 clinics: ≥0.6 contacts seen per index case based on index case report, and ≥0.4 contacts seen per index case based on HCW verification, both within four weeks of the first partner notification interview. The results are discussed with regard to the importance of adoption of standards by commissioners of services, relevance to national quality agendas, and the need for development of a national system of PN quality assurance measurement and reporting.

  10. 40 CFR Table 3 to Subpart Lllll of... - Requirements for Performance Tests a,b

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., THC destruction efficiency, THC outlet concentration, or combustion efficiency standards, the sampling... combustion efficiency or THC standards a. Measure the concentration of carbon dioxideb. Measure the... method 25A in appendix A to part 60 of this chapter 10. Each control device used to comply with the THC...

  11. 40 CFR Table 3 to Subpart Lllll of... - Requirements for Performance Tests a,b

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., THC destruction efficiency, THC outlet concentration, or combustion efficiency standards, the sampling... combustion efficiency or THC standards a. Measure the concentration of carbon dioxideb. Measure the... method 25A in appendix A to part 60 of this chapter 10. Each control device used to comply with the THC...

  12. 40 CFR Table 3 to Subpart Lllll of... - Requirements for Performance Tests a,b

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., THC destruction efficiency, THC outlet concentration, or combustion efficiency standards, the sampling... combustion efficiency or THC standards a. Measure the concentration of carbon dioxideb. Measure the... method 25A in appendix A to part 60 of this chapter 10. Each control device used to comply with the THC...

  13. 40 CFR Table 3 to Subpart Lllll of... - Requirements for Performance Tests a b

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., THC destruction efficiency, THC outlet concentration, or combustion efficiency standards, the sampling... combustion efficiency or THC standards a. Measure the concentration of carbon dioxideb. Measure the... method 25A in appendix A to part 60 of this chapter 10. Each control device used to comply with the THC...

  14. 40 CFR Table 3 to Subpart Lllll of... - Requirements for Performance Tests a,b

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., THC destruction efficiency, THC outlet concentration, or combustion efficiency standards, the sampling... combustion efficiency or THC standards a. Measure the concentration of carbon dioxideb. Measure the... method 25A in appendix A to part 60 of this chapter 10. Each control device used to comply with the THC...

  15. Test Anxiety and High-Stakes Test Performance between School Settings: Implications for Educators

    ERIC Educational Resources Information Center

    von der Embse, Nathaniel; Hasson, Ramzi

    2012-01-01

    With the enactment of standards-based accountability in education, high-stakes tests have become the dominant method for measuring school effectiveness and student achievement. Schools and educators are under increasing pressure to meet achievement standards. However, there are variables which may interfere with the authentic measurement of…

  16. MAP Science for Use with Next Generation Science Standards. NWEA External FAQ

    ERIC Educational Resources Information Center

    Northwest Evaluation Association, 2016

    2016-01-01

    Measures of Academic Progress® (MAP®) Science for use with Next Generation Science Standards (NGSS) assessments are available for the 2016-17 school year. These new assessments measure student growth toward understanding of the multidimensional NGSS performance expectations. This report presents MAP Science for use with NGSS by presenting and…

  17. Hospital Performance Trends on National Quality Measures and the Association With Joint Commission Accreditation

    PubMed Central

    Schmaltz, Stephen P; Williams, Scott C; Chassin, Mark R; Loeb, Jerod M; Wachter, Robert M

    2011-01-01

    BACKGROUND Evaluations of the impact of hospital accreditation have been previously hampered by the lack of nationally standardized data. One way to assess this impact is to compare accreditation status with other evidence-based measures of quality, such as the process measures now publicly reported by The Joint Commission and the Centers for Medicare and Medicaid Services (CMS). OBJECTIVES To examine the association between Joint Commission accreditation status and both absolute measures of, and trends in, hospital performance on publicly reported quality measures for common diseases. DESIGN, SETTING, AND PATIENTS Performance data for 2004 and 2008 from U.S. acute care and critical access hospitals were obtained using publicly available CMS Hospital Compare data augmented with Joint Commission performance data. MEASUREMENTS Changes in hospital performance between 2004 and 2008, and percent of hospitals with 2008 performance exceeding 90% for 16 measures of quality-of-care and 4 summary scores. RESULTS Hospitals accredited by The Joint Commission tended to have better baseline performance in 2004 than non-accredited hospitals. Accredited hospitals had larger gains over time, and were significantly more likely to have high performance in 2008 on 13 out of 16 standardized clinical performance measures and all summary scores. CONCLUSIONS While Joint Commission-accredited hospitals already outperformed non-accredited hospitals on publicly reported quality measures in the early days of public reporting, these differences became significantly more pronounced over 5 years of observation. Future research should examine whether accreditation actually promotes improved performance or is a marker for other hospital characteristics associated with such performance. Journal of Hospital Medicine 2011;6:458–465. © 2011 Society of Hospital Medicine PMID:21990175

  18. Evaluation of Acoustic Doppler Current Profiler measurements of river discharge

    USGS Publications Warehouse

    Morlock, S.E.

    1996-01-01

    The standard deviations of the ADCP measurements ranged from approximately 1 to 6 percent and were generally higher than the measurement errors predicted by error-propagation analysis of ADCP instrument performance. These error-prediction methods assume that the largest component of ADCP discharge measurement error is instrument related. The larger standard deviations indicate that substantial portions of measurement error may be attributable to sources unrelated to ADCP electronics or signal processing and are functions of the field environment.

  19. Using inductively coupled plasma-mass spectrometry for calibration transfer between environmental CRMs.

    PubMed

    Turk, G C; Yu, L L; Salit, M L; Guthrie, W F

    2001-06-01

    Multielement analyses of environmental reference materials have been performed using existing certified reference materials (CRMs) as calibration standards for inductively coupled plasma-mass spectrometry. The analyses have been performed using a high-performance methodology that results in comparison measurement uncertainties that are significantly less than the uncertainties of the certified values of the calibration CRM. Consequently, the determined values have uncertainties that are very nearly equivalent to the uncertainties of the calibration CRM. Several uses of this calibration transfer are proposed, including, re-certification measurements of replacement CRMs, establishing traceability of one CRM to another, and demonstrating the equivalence of two CRMs. RM 8704, a river sediment, was analyzed using SRM 2704, Buffalo River Sediment, as the calibration standard. SRM 1632c, Trace Elements in Bituminous Coal, which is a replacement for SRM 1632b, was analyzed using SRM 1632b as the standard. SRM 1635, Trace Elements in Subbituminous Coal, was also analyzed using SRM 1632b as the standard.

  20. Standard operation procedures for conducting the on-the-road driving test, and measurement of the standard deviation of lateral position (SDLP)

    PubMed Central

    Verster, Joris C; Roth, Thomas

    2011-01-01

    This review discusses the methodology of the standardized on-the-road driving test and standard operation procedures to conduct the test and analyze the data. The on-the-road driving test has proven to be a sensitive and reliable method to examine driving ability after administration of central nervous system (CNS) drugs. The test is performed on a public highway in normal traffic. Subjects are instructed to drive with a steady lateral position and constant speed. Its primary parameter, the standard deviation of lateral position (SDLP), ie, an index of ‘weaving’, is a stable measure of driving performance with high test–retest reliability. SDLP differences from placebo are dose-dependent, and do not depend on the subject’s baseline driving skills (placebo SDLP). It is important that standard operation procedures are applied to conduct the test and analyze the data in order to allow comparisons between studies from different sites. PMID:21625472

  1. Standard operation procedures for conducting the on-the-road driving test, and measurement of the standard deviation of lateral position (SDLP).

    PubMed

    Verster, Joris C; Roth, Thomas

    2011-01-01

    This review discusses the methodology of the standardized on-the-road driving test and standard operation procedures to conduct the test and analyze the data. The on-the-road driving test has proven to be a sensitive and reliable method to examine driving ability after administration of central nervous system (CNS) drugs. The test is performed on a public highway in normal traffic. Subjects are instructed to drive with a steady lateral position and constant speed. Its primary parameter, the standard deviation of lateral position (SDLP), ie, an index of 'weaving', is a stable measure of driving performance with high test-retest reliability. SDLP differences from placebo are dose-dependent, and do not depend on the subject's baseline driving skills (placebo SDLP). It is important that standard operation procedures are applied to conduct the test and analyze the data in order to allow comparisons between studies from different sites.

  2. PERFORMANCE-BASED CONTRACTING IN CONSTRUCTION PHASE AND MAINTENANCE PHASE OF PAVEMENT

    NASA Astrophysics Data System (ADS)

    Yoshida, Takeshi

    Performance-based contracting for pavement in Japan started as performance warranties in construction phase, in 1999. Recently, road agencies have recognized the applicability of this type of contracting in outsourcing of maintenance activities. The objectives of this study are to clarify the issues of performance specifying in construction phase and maintenance phase of pavement, and to propose measures to be taken. This paper, with the recognition that the life of each pavement depends on performance standards for various attributes, reviews domestic and foreign examples of performance-based contracting. A performance standard based on the average of current practices can enhance product quality and service life with a warranty contract. Repair thresholds and response time for each deficiency should be considered as performance standards in maintenance phase.

  3. Comparison of air-kerma strength determinations for HDR (192)Ir sources.

    PubMed

    Rasmussen, Brian E; Davis, Stephen D; Schmidt, Cal R; Micka, John A; Dewerd, Larry A

    2011-12-01

    To perform a comparison of the interim air-kerma strength standard for high dose rate (HDR) (192)Ir brachytherapy sources maintained by the University of Wisconsin Accredited Dosimetry Calibration Laboratory (UWADCL) with measurements of the various source models using modified techniques from the literature. The current interim standard was established by Goetsch et al. in 1991 and has remained unchanged to date. The improved, laser-aligned seven-distance apparatus of the University of Wisconsin Medical Radiation Research Center (UWMRRC) was used to perform air-kerma strength measurements of five different HDR (192)Ir source models. The results of these measurements were compared with those from well chambers traceable to the original standard. Alternative methodologies for interpolating the (192)Ir air-kerma calibration coefficient from the NIST air-kerma standards at (137)Cs and 250 kVp x rays (M250) were investigated and intercompared. As part of the interpolation method comparison, the Monte Carlo code EGSnrc was used to calculate updated values of A(wall) for the Exradin A3 chamber used for air-kerma strength measurements. The effects of air attenuation and scatter, room scatter, as well as the solution method were investigated in detail. The average measurements when using the inverse N(K) interpolation method for the Classic Nucletron, Nucletron microSelectron, VariSource VS2000, GammaMed Plus, and Flexisource were found to be 0.47%, -0.10%, -1.13%, -0.20%, and 0.89% different than the existing standard, respectively. A further investigation of the differences observed between the sources was performed using MCNP5 Monte Carlo simulations of each source model inside a full model of an HDR 1000 Plus well chamber. Although the differences between the source models were found to be statistically significant, the equally weighted average difference between the seven-distance measurements and the well chambers was 0.01%, confirming that it is not necessary to update the current standard maintained at the UWADCL.

  4. Is vision function related to physical functional ability in older adults?

    PubMed

    West, Catherine G; Gildengorin, Ginny; Haegerstrom-Portnoy, Gunilla; Schneck, Marilyn E; Lott, Lori; Brabyn, John A

    2002-01-01

    To assess the relationship between a broad range of vision functions and measures of physical performance in older adults. Cross-sectional study. Population-based cohort of community-dwelling older adults, subset of an on-going longitudinal study. Seven hundred eighty-two adults aged 55 and older (65% of living eligible subjects) had subjective health measures and objective physical performance evaluated in 1989/91 and again in 1993/95 and a battery of vision functions tested in 1993/95. Comprehensive battery of vision tests (visual acuity, contrast sensitivity, effects of illumination level, contrast and glare on acuity, visual fields with and without attentional load, color vision, temporal sensitivity, and the impact of dimming light on walking ability) and physical function measures (self-reported mobility limitations and observed measures of walking, rising from a chair and tandem balance). The failure rate for all vision functions and physical performance measures increased exponentially with age. Standard high-contrast visual acuity and standard visual fields showed the lowest failure rates. Nonstandard vision tests showed much higher failure rates. Poor performance on many individual vision functions was significantly associated with particular individual measures of physical performance. Using constructed combination vision variables, significant associations were found between spatial vision, field integrity, binocularity and/or adaptation, and each of the functional outcomes. Vision functions other than standard visual acuity may affect day-to-day functioning of older adults. Additional studies of these other aspects of vision and how they can be treated or rehabilitated are needed to determine whether these aspects play a role in strategies for reducing disability in older adults.

  5. Mortality Measures to Profile Hospital Performance for Patients With Septic Shock.

    PubMed

    Walkey, Allan J; Shieh, Meng-Shiou; Liu, Vincent X; Lindenauer, Peter K

    2018-04-30

    Sepsis care is becoming a more common target for hospital performance measurement, but few studies have evaluated the acceptability of sepsis or septic shock mortality as a potential performance measure. In the absence of a gold standard to identify septic shock in claims data, we assessed agreement and stability of hospital mortality performance under different case definitions. Retrospective cohort study. U.S. acute care hospitals. Hospitalized with septic shock at admission, identified by either implicit diagnosis criteria (charges for antibiotics, cultures, and vasopressors) or by explicit International Classification of Diseases, 9th revision, codes. None. We used hierarchical logistic regression models to determine hospital risk-standardized mortality rates and hospital performance outliers. We assessed agreement in hospital mortality rankings when septic shock cases were identified by either explicit International Classification of Diseases, 9th revision, codes or implicit diagnosis criteria. Kappa statistics and intraclass correlation coefficients were used to assess agreement in hospital risk-standardized mortality and hospital outlier status, respectively. Fifty-six thousand six-hundred seventy-three patients in 308 hospitals fulfilled at least one case definition for septic shock, whereas 19,136 (33.8%) met both the explicit International Classification of Diseases, 9th revision, and implicit septic shock definition. Hospitals varied widely in risk-standardized septic shock mortality (interquartile range of implicit diagnosis mortality: 25.4-33.5%; International Classification of Diseases, 9th revision, diagnosis: 30.2-38.0%). The median absolute difference in hospital ranking between septic shock cohorts defined by International Classification of Diseases, 9th revision, versus implicit criteria was 37 places (interquartile range, 16-70), with an intraclass correlation coefficient of 0.72, p value of less than 0.001; agreement between case definitions for identification of outlier hospitals was moderate (kappa, 0.44 [95% CI, 0.30-0.58]). Risk-standardized septic shock mortality rates varied considerably between hospitals, suggesting that septic shock is an important performance target. However, efforts to profile hospital performance were sensitive to septic shock case definitions, suggesting that septic shock mortality is not currently ready for widespread use as a hospital quality measure.

  6. Measures That Matter: Why California Should Scrap the Academic Performance Index. Education Sector Reports

    ERIC Educational Resources Information Center

    Colvin, Richard Lee

    2012-01-01

    California's Academic Performance Index (API) is the state's main accountability metric. Authorized by the Legislature in 1999, around the time California was implementing rigorous new standards in math, science, social studies, and English language arts, the API relies heavily on the results of standardized tests designed to align with those…

  7. Experience with local lymph node assay performance standards using standard radioactivity and nonradioactive cell count measurements.

    PubMed

    Basketter, David; Kolle, Susanne N; Schrage, Arnhild; Honarvar, Naveed; Gamer, Armin O; van Ravenzwaay, Bennard; Landsiedel, Robert

    2012-08-01

    The local lymph node assay (LLNA) is the preferred test for identification of skin-sensitizing substances by measuring radioactive thymidine incorporation into the lymph node. To facilitate acceptance of nonradioactive variants, validation authorities have published harmonized minimum performance standards (PS) that the alternative endpoint assay must meet. In the present work, these standards were applied to a variant of the LLNA based on lymph node cell counts (LNCC) run in parallel as a control with the standard LLNA with radioactivity measurements, with threshold concentrations (EC3) being determined for the sensitizers. Of the 22 PS chemicals tested in this study, 21 yielded the same results from standard radioactivity and cell count measurements; only 2-mercaptobenzothiazole was positive by LLNA but negative by LNCC. Of the 16 PS positives, 15 were positive by LLNA and 14 by LNCC; methylmethacrylate was not identified as sensitizer by either of the measurements. Two of the six PS negatives tested negative in our study by both LLNA and LNCC. Of the four PS negatives which were positive in our study, chlorobenzene and methyl salicylate were tested at higher concentrations than the published PS, whereas the corresponding concentrations resulted in consistent negative results. Methylmethacrylate and nickel chloride tested positive within the concentration range used for the published PS. The results indicate cell counts and radioactive measurements are in good accordance within the same LLNA using the 22 PS test substances. Comparisons with the published PS results may, however, require balanced analysis rather than a simple checklist approach. Copyright © 2011 John Wiley & Sons, Ltd.

  8. Measurement of Energy Performances for General-Structured Servers

    NASA Astrophysics Data System (ADS)

    Liu, Ren; Chen, Lili; Li, Pengcheng; Liu, Meng; Chen, Haihong

    2017-11-01

    Energy consumption of servers in data centers increases rapidly along with the wide application of Internet and connected devices. To improve the energy efficiency of servers, voluntary or mandatory energy efficiency programs for servers, including voluntary label program or mandatory energy performance standards have been adopted or being prepared in the US, EU and China. However, the energy performance of servers and testing methods of servers are not well defined. This paper presents matrices to measure the energy performances of general-structured servers. The impacts of various components of servers on their energy performances are also analyzed. Based on a set of normalized workload, the author proposes a standard method for testing energy efficiency of servers. Pilot tests are conducted to assess the energy performance testing methods of servers. The findings of the tests are discussed in the paper.

  9. Measuring Principal Performance: How Rigorous Are Commonly Used Principal Performance Assessment Instruments? A Quality School Leadership Issue Brief. Revised

    ERIC Educational Resources Information Center

    Condon, Christopher; Clifford, Matthew

    2012-01-01

    Assessing school principal performance is both necessary and challenging. During the past five years, many states have begun using validated measures in summative assessments of novice principal competency as a basis for certification decisions. Although standardized tests are used for certification purposes, other types of assessments are being…

  10. Solar cell and module performance assessment based on indoor calibration methods

    NASA Astrophysics Data System (ADS)

    Bogus, K.

    A combined space/terrestrial solar cell test calibration method that requires five steps and can be performed indoors is described. The test conditions are designed to qualify the cell or module output data in standard illumination and temperature conditions. Measurements are made of the short-circuit current, the open circuit voltage, the maximum power, the efficiency, and the spectral response. Standard sunlight must be replicated both in earth surface and AM0 conditions; Xe lamps are normally used for the light source, with spectral measurements taken of the light. Cell and module spectral response are assayed by using monochromators and narrow band pass monochromatic filters. Attention is required to define the performance characteristics of modules under partial shadowing. Error sources that may effect the measurements are discussed, as are previous cell performance testing and calibration methods and their effectiveness in comparison with the behaviors of satellite solar power panels.

  11. A star-and-sky chopping polarimeter - Design and performance

    NASA Astrophysics Data System (ADS)

    Jain, S. K.; Srinivasulu, G.

    1991-09-01

    A star-and-sky chopping polarimeter is developed for accurate measurements of linear polarization of starlight in the standard astronomical photometric U, B, V, R, and I bands. The instrumental polarization, as determined by observing the standard unpolarized stars, is 0.04 percent. It is possible to use the instrument for the measurements of circular polarization as well. A Unicorn microcomputer controls the various operations of the instrument, acquires the data, and does the on-line data reduction. This paper describes the design and performance of the polarimeter.

  12. Improving integrity of on-line grammage measurement with traceable basic calibration.

    PubMed

    Kangasrääsiö, Juha

    2010-07-01

    The automatic control of grammage (basis weight) in paper and board production is based upon on-line grammage measurement. Furthermore, the automatic control of other quality variables such as moisture, ash content and coat weight, may rely on the grammage measurement. The integrity of Kr-85 based on-line grammage measurement systems was studied, by performing basic calibrations with traceably calibrated plastic reference standards. The calibrations were performed according to the EN ISO/IEC 17025 standard, which is a requirement for calibration laboratories. The observed relative measurement errors were 3.3% in the first time calibrations at the 95% confidence level. With the traceable basic calibration method, however, these errors can be reduced to under 0.5%, thus improving the integrity of on-line grammage measurements. Also a standardised algorithm, based on the experience from the performed calibrations, is proposed to ease the adjustment of the different grammage measurement systems. The calibration technique can basically be applied to all beta-radiation based grammage measurements. 2010 ISA. Published by Elsevier Ltd. All rights reserved.

  13. Ultrasound Metrology in Mexico: a round robin test for medical diagnostics

    NASA Astrophysics Data System (ADS)

    Amezola Luna, R.; López Sánchez, A. L.; Elías Juárez, A. A.

    2011-02-01

    This paper presents preliminary statistical results from an on-going imaging medical ultrasound study, of particular relevance for gynecology and obstetrics areas. Its scope is twofold, firstly to compile the medical ultrasound infrastructure available in cities of Queretaro-Mexico, and second to promote the use of traceable measurement standards as a key aspect to assure quality of ultrasound examinations performed by medical specialists. The experimental methodology is based on a round robin test using an ultrasound phantom for medical imaging. The physician, using its own ultrasound machine, couplant and facilities, measures the size and depth of a set of pre-defined reflecting and absorbing targets of the reference phantom, which simulate human illnesses. Measurements performed give the medical specialist an objective feedback regarding some performance characteristics of their ultrasound examination systems, such as measurement system accuracy, dead zone, axial resolution, depth of penetration and anechoic targets detection. By the end of March 2010, 66 entities with medical ultrasound facilities, from both public and private institutions, have performed measurements. A network of medical ultrasound calibration laboratories in Mexico, with traceability to The International System of Units via national measurement standards, may indeed contribute to reduce measurement deviations and thus attain better diagnostics.

  14. Locally Developed Performance Assessments: One State's Decision to Supplant Standardized Tests with Alternative Measures

    ERIC Educational Resources Information Center

    Abbott, Amy Lynn

    2016-01-01

    The purpose for this study was to develop a descriptive account of one large Virginia school district's plan for implementation of alternative, locally developed assessments designed to supplant standardized measures. As policy reform with alternative assessments has been under-researched for the past 30 years, there is a need for studies…

  15. How Accurate Is a Test Score?

    ERIC Educational Resources Information Center

    Doppelt, Jerome E.

    1956-01-01

    The standard error of measurement as a means for estimating the margin of error that should be allowed for in test scores is discussed. The true score measures the performance that is characteristic of the person tested; the variations, plus and minus, around the true score describe a characteristic of the test. When the standard deviation is used…

  16. Transmissivity testing of multilayer insulation at cryogenic temperatures

    NASA Astrophysics Data System (ADS)

    Johnson, W. L.; Van Dresar, N. T.; Chato, D. J.; Demers, J. R.

    2017-09-01

    The problem of degraded emissivity of thin films at low temperatures has been a long observed phenomena. Previous efforts at measuring properties have suggested that transmission of energy through the films may play a key role in the thermal performance of multilayer insulation systems at low temperatures. Similarly, recent testing on tank applied systems has suggested a radiative degradation at low temperatures. Two different approaches were used to attempt to measure the transmission of energy through MLI at low temperatures. A laser based measurement system was set up to directly measure transmittance and a calorimetric based measurement system was used to measure relative emittance of a single layer between aluminum foil and double aluminized Mylar. Minimal transmission at long wavelengths were observed through standard MLI blanket materials at deposition thicknesses of even 35 nm. Where transmission was measured, it was too low to effect the performance of a multilayers system. Similarly, the calorimeter showed similar increases of emissivity for both standard blanket materials and aluminum foils. Multiple different methodologies of measurement have all yielded the same result: that there is no transmission through standard MLI blanket materials at wavelengths associated with temperatures as low as 2 K.

  17. 48 CFR 37.602 - Performance work statement.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... on the use of measurable performance standards and financial incentives in a competitive environment... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Performance work statement... CATEGORIES OF CONTRACTING SERVICE CONTRACTING Performance-Based Acquisition 37.602 Performance work statement...

  18. The COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) and how to select an outcome measurement instrument.

    PubMed

    Mokkink, Lidwine B; Prinsen, Cecilia A C; Bouter, Lex M; Vet, Henrica C W de; Terwee, Caroline B

    2016-01-19

    COSMIN (COnsensus-based Standards for the selection of health Measurement INstruments) is an initiative of an international multidisciplinary team of researchers who aim to improve the selection of outcome measurement instruments both in research and in clinical practice by developing tools for selecting the most appropriate available instrument. In this paper these tools are described, i.e. the COSMIN taxonomy and definition of measurement properties; the COSMIN checklist to evaluate the methodological quality of studies on measurement properties; a search filter for finding studies on measurement properties; a protocol for systematic reviews of outcome measurement instruments; a database of systematic reviews of outcome measurement instruments; and a guideline for selecting outcome measurement instruments for Core Outcome Sets in clinical trials. Currently, we are updating the COSMIN checklist, particularly the standards for content validity studies. Also new standards for studies using Item Response Theory methods will be developed. Additionally, in the future we want to develop standards for studies on the quality of non-patient reported outcome measures, such as clinician-reported outcomes and performance-based outcomes. In summary, we plea for more standardization in the use of outcome measurement instruments, for conducting high quality systematic reviews on measurement instruments in which the best available outcome measurement instrument is recommended, and for stopping the use of poor outcome measurement instruments.

  19. The COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) and how to select an outcome measurement instrument

    PubMed Central

    Mokkink, Lidwine B.; Prinsen, Cecilia A. C.; Bouter, Lex M.; de Vet, Henrica C. W.; Terwee, Caroline B.

    2016-01-01

    Background: COSMIN (COnsensus-based Standards for the selection of health Measurement INstruments) is an initiative of an international multidisciplinary team of researchers who aim to improve the selection of outcome measurement instruments both in research and in clinical practice by developing tools for selecting the most appropriate available instrument. Method: In this paper these tools are described, i.e. the COSMIN taxonomy and definition of measurement properties; the COSMIN checklist to evaluate the methodological quality of studies on measurement properties; a search filter for finding studies on measurement properties; a protocol for systematic reviews of outcome measurement instruments; a database of systematic reviews of outcome measurement instruments; and a guideline for selecting outcome measurement instruments for Core Outcome Sets in clinical trials. Currently, we are updating the COSMIN checklist, particularly the standards for content validity studies. Also new standards for studies using Item Response Theory methods will be developed. Additionally, in the future we want to develop standards for studies on the quality of non-patient reported outcome measures, such as clinician-reported outcomes and performance-based outcomes. Conclusions: In summary, we plea for more standardization in the use of outcome measurement instruments, for conducting high quality systematic reviews on measurement instruments in which the best available outcome measurement instrument is recommended, and for stopping the use of poor outcome measurement instruments. PMID:26786084

  20. 40 CFR 60.221 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for the Phosphate Fertilizer Industry... ammonia. (b) Total fluorides means elemental fluorine and all fluoride compounds as measured by reference...

  1. 40 CFR 60.221 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for the Phosphate Fertilizer Industry... ammonia. (b) Total fluorides means elemental fluorine and all fluoride compounds as measured by reference...

  2. 40 CFR 60.221 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for the Phosphate Fertilizer Industry... ammonia. (b) Total fluorides means elemental fluorine and all fluoride compounds as measured by reference...

  3. 40 CFR 60.221 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for the Phosphate Fertilizer Industry... ammonia. (b) Total fluorides means elemental fluorine and all fluoride compounds as measured by reference...

  4. 40 CFR 60.221 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for the Phosphate Fertilizer Industry... ammonia. (b) Total fluorides means elemental fluorine and all fluoride compounds as measured by reference...

  5. The National Shipbuilding Research Program: Contaminated Sediment Management Guide for NSRP Shipyards. Appendix 4: Removal Technologies

    DTIC Science & Technology

    1999-10-22

    la performance technique et environnementale de PAmphibex Journal: Report for Environment Canada-Quebec Region and Environment Quebec Date: Mar 1995...cell. Exceed Set Standards? This demonstration was used to finalize operational and performance standards to be used for the audit of innovative...suspended solids measurements will be performed inside the confined area in order to audit the removal technology. All provisions should be taken to

  6. Development of minimum standards for event-based data collection loggers and performance measure definitions for signalized intersections.

    DOT National Transportation Integrated Search

    2017-01-01

    The arterial traffic signal performance measures were not used to their fullest potential in the past. The development of traffic signal controllers with event-based, high-resolution data logging capabilities enabled the advances in derivation and vi...

  7. Measuring Performance in Child Welfare: Secondary Effects of Success.

    ERIC Educational Resources Information Center

    Usher, Charles L.; Gibbs, Deborah A.; Wildfire, Judith B.

    1999-01-01

    Draws on findings from evaluations of recent reform initiatives in Alabama, North Carolina, and Ohio to suggest that performance-measurement systems for state child-welfare programs must adapt to changing circumstances, especially when improvements in one area can influence standards and expectations in others. (Author/KB)

  8. Challenges in standardization of blood pressure measurement at the population level.

    PubMed

    Tolonen, Hanna; Koponen, Päivikki; Naska, Androniki; Männistö, Satu; Broda, Grazyna; Palosaari, Tarja; Kuulasmaa, Kari

    2015-04-10

    Accurate blood pressure measurements are needed in clinical practice, intervention studies and health examination surveys. Blood pressure measurements are sensitive: their accuracy can be affected by measurement environment, behaviour of the subject, measurement procedures, devices used for the measurement and the observer. To minimize errors in blood pressure measurement, a standardized measurement protocol is needed. The European Health Examination Survey (EHES) Pilot project was conducted in 2009-2012. A pilot health examination survey was conducted in 12 countries using a standardized protocol. The measurement protocols used in each survey, training provided for the measurers, measurement data, and observations during site visits were collected and evaluated to assess the level of standardization. The EHES measurement protocol for blood pressure was followed accurately in all 12 pilot surveys. Most of the surveys succeeded in organizing a quiet and comfortable measurement environment, and staff instructed survey participants appropriately before examination visits. In all surveys, blood pressure was measured three times, from the right arm in a sitting posture. The biggest variation was in the device used for the blood pressure measurement. It is possible to reach a high level of standardization for blood pressure measurements across countries and over time. A detailed, standardized measurement protocol, and adequate training and monitoring during the fieldwork and centrally organized quality assessment of the data are needed. The recent EU regulation banning the sale of mercury sphygmomanometer in European Union Member States has set new challenges for the standardization of measurement devices since the validity of oscillometric measurements is device-specific and performance of aneroid devices depends very much on calibration.

  9. 20 CFR 669.500 - What performance measures and standards apply to the NFJP?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... must be included in the approved plan. (b) We may develop additional performance indicators with... service area economy and local demographics of eligible MSFW's. The levels of performance for these...

  10. Capturing the imagination of nurse executives in tracking the quality of nursing care.

    PubMed

    Kurtzman, Ellen T; Jennings, Bonnie M

    2008-01-01

    Nurses represent the single largest healthcare profession in the United States. A growing evidence base demonstrates nursing's direct influence on inpatient safety and healthcare outcomes. Support for nursing's essential role in quality and patient safety and mounting interest in publicly reporting performance results have led to efforts to standardized nursing-sensitive performance measures. To this end, in 2004, the National Quality Forum endorsed a set of 15 nursing-sensitive consensus standards intended for use by the public in assessing inpatient nursing care. However, until recently, only anecdotal knowledge existed regarding the implementation of these consensus standards. As a step toward better understanding the interest in and adoption of nursing performance measures, The Robert Wood Johnson Foundation funded a study that concluded in March 2007. In this article, findings from the study are summarized as they apply to nursing leadership and implications for the future role of the nurse executive.

  11. Seven Performance Drivers.

    ERIC Educational Resources Information Center

    Ross, Linda

    2003-01-01

    Recent work with automotive e-commerce clients led to the development of a performance analysis methodology called the Seven Performance Drivers, including: standards, incentives, capacity, knowledge and skill, measurement, feedback, and analysis. This methodology has been highly effective in introducing and implementing performance improvement.…

  12. A novel, simplified ex vivo method for measuring water exchange performance of heat and moisture exchangers for tracheostomy application.

    PubMed

    van den Boer, Cindy; Muller, Sara H; Vincent, Andrew D; Züchner, Klaus; van den Brekel, Michiel W M; Hilgers, Frans J M

    2013-09-01

    Breathing through a tracheostomy results in insufficient warming and humidification of inspired air. This loss of air-conditioning can be partially compensated for with the application of a heat and moisture exchanger (HME) over the tracheostomy. In vitro (International Organization for Standardization [ISO] standard 9360-2:2001) and in vivo measurements of the effects of an HME are complex and technically challenging. The aim of this study was to develop a simple method to measure the ex vivo HME performance comparable with previous in vitro and in vivo results. HMEs were weighed at the end of inspiration and at the end of expiration at different breathing volumes. Four HMEs (Atos Medical, Hörby, Sweden) with known in vivo humidity and in vitro water loss values were tested. The associations between weight change, volume, and absolute humidity were determined using both linear and non-linear mixed effects models. The rating between the 4 HMEs by weighing correlated with previous intra-tracheal measurements (R(2) = 0.98), and the ISO standard (R(2) = 0.77). Assessment of the weight change between end of inhalation and end of exhalation is a valid and simple method of measuring the water exchange performance of an HME.

  13. Computerized tomography magnified bone windows are superior to standard soft tissue windows for accurate measurement of stone size: an in vitro and clinical study.

    PubMed

    Eisner, Brian H; Kambadakone, Avinash; Monga, Manoj; Anderson, James K; Thoreson, Andrew A; Lee, Hang; Dretler, Stephen P; Sahani, Dushyant V

    2009-04-01

    We determined the most accurate method of measuring urinary stones on computerized tomography. For the in vitro portion of the study 24 calculi, including 12 calcium oxalate monohydrate and 12 uric acid stones, that had been previously collected at our clinic were measured manually with hand calipers as the gold standard measurement. The calculi were then embedded into human kidney-sized potatoes and scanned using 64-slice multidetector computerized tomography. Computerized tomography measurements were performed at 4 window settings, including standard soft tissue windows (window width-320 and window length-50), standard bone windows (window width-1120 and window length-300), 5.13x magnified soft tissue windows and 5.13x magnified bone windows. Maximum stone dimensions were recorded. For the in vivo portion of the study 41 patients with distal ureteral stones who underwent noncontrast computerized tomography and subsequently spontaneously passed the stones were analyzed. All analyzed stones were 100% calcium oxalate monohydrate or mixed, calcium based stones. Stones were prospectively collected at the clinic and the largest diameter was measured with digital calipers as the gold standard. This was compared to computerized tomography measurements using 4.0x magnified soft tissue windows and 4.0x magnified bone windows. Statistical comparisons were performed using Pearson's correlation and paired t test. In the in vitro portion of the study the most accurate measurements were obtained using 5.13x magnified bone windows with a mean 0.13 mm difference from caliper measurement (p = 0.6). Measurements performed in the soft tissue window with and without magnification, and in the bone window without magnification were significantly different from hand caliper measurements (mean difference 1.2, 1.9 and 1.4 mm, p = 0.003, <0.001 and 0.0002, respectively). When comparing measurement errors between stones of different composition in vitro, the error for calcium oxalate calculi was significantly different from the gold standard for all methods except bone window settings with magnification. For uric acid calculi the measurement error was observed only in standard soft tissue window settings. In vivo 4.0x magnified bone windows was superior to 4.0x magnified soft tissue windows in measurement accuracy. Magnified bone window measurements were not statistically different from digital caliper measurements (mean underestimation vs digital caliper 0.3 mm, p = 0.4), while magnified soft tissue windows were statistically distinct (mean underestimation 1.4 mm, p = 0.001). In this study magnified bone windows were the most accurate method of stone measurements in vitro and in vivo. Therefore, we recommend the routine use of magnified bone windows for computerized tomography measurement of stones. In vitro the measurement error in calcium oxalate stones was greater than that in uric acid stones, suggesting that stone composition may be responsible for measurement inaccuracies.

  14. Academy of nutrition and dietetics: revised 2014 standards of practice and standards of professional performance for registered dietitian nutritionists (competent, proficient, and expert) in sports nutrition and dietetics.

    PubMed

    Steinmuller, Patricia L; Kruskall, Laura J; Karpinski, Christine A; Manore, Melinda M; Macedonio, Michele A; Meyer, Nanna L

    2014-04-01

    Sports nutrition and dietetics addresses relationships of nutrition with physical activity, including weight management, exercise, and physical performance. Nutrition plays a key role in the prevention and treatment of obesity and chronic disease and for maintenance of health, and the ability to engage in physical activity, sports, and other aspects of physical performance. Thus, the Sports, Cardiovascular, and Wellness Nutrition Dietetic Practice Group, with guidance from the Academy of Nutrition and Dietetics Quality Management Committee, has developed the Revised 2014 Standards of Practice and Standards of Professional Performance as a resource for Registered Dietitian Nutritionists working in sports nutrition and dietetics to assess their current skill levels and to identify areas for further professional development in this emerging practice area. The revised document reflects advances in sports nutrition and dietetics practice since the original standards were published in 2009 and replaces those standards. The Standards of Practice represents the four steps in the Nutrition Care Process as applied to the care of patients/clients. The Standards of Professional Performance covers six standards of professional performance: quality in practice, competence and accountability, provision of services, application of research, communication and application of knowledge, and utilization and management of resources. Within each standard, specific indicators provide measurable action statements that illustrate how the standards can be applied to practice. The indicators describe three skill levels (competent, proficient, and expert) for Registered Dietitian Nutritionists working in sports nutrition and dietetics. The Standards of Practice and Standards of Professional Performance are complementary resources for Registered Dietitian Nutritionists in sports nutrition and dietetics practice. Copyright © 2014 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  15. Statistical properties of four effect-size measures for mediation models.

    PubMed

    Miočević, Milica; O'Rourke, Holly P; MacKinnon, David P; Brown, Hendricks C

    2018-02-01

    This project examined the performance of classical and Bayesian estimators of four effect size measures for the indirect effect in a single-mediator model and a two-mediator model. Compared to the proportion and ratio mediation effect sizes, standardized mediation effect-size measures were relatively unbiased and efficient in the single-mediator model and the two-mediator model. Percentile and bias-corrected bootstrap interval estimates of ab/s Y , and ab(s X )/s Y in the single-mediator model outperformed interval estimates of the proportion and ratio effect sizes in terms of power, Type I error rate, coverage, imbalance, and interval width. For the two-mediator model, standardized effect-size measures were superior to the proportion and ratio effect-size measures. Furthermore, it was found that Bayesian point and interval summaries of posterior distributions of standardized effect-size measures reduced excessive relative bias for certain parameter combinations. The standardized effect-size measures are the best effect-size measures for quantifying mediated effects.

  16. N2/O2/H2 Dual-Pump Cars: Validation Experiments

    NASA Technical Reports Server (NTRS)

    OByrne, S.; Danehy, P. M.; Cutler, A. D.

    2003-01-01

    The dual-pump coherent anti-Stokes Raman spectroscopy (CARS) method is used to measure temperature and the relative species densities of N2, O2 and H2 in two experiments. Average values and root-mean-square (RMS) deviations are determined. Mean temperature measurements in a furnace containing air between 300 and 1800 K agreed with thermocouple measurements within 26 K on average, while mean mole fractions agree to within 1.6 % of the expected value. The temperature measurement standard deviation averaged 64 K while the standard deviation of the species mole fractions averaged 7.8% for O2 and 3.8% for N2, based on 200 single-shot measurements. Preliminary measurements have also been performed in a flat-flame burner for fuel-lean and fuel-rich flames. Temperature standard deviations of 77 K were measured, and the ratios of H2 to N2 and O2 to N2 respectively had standard deviations from the mean value of 12.3% and 10% of the measured ratio.

  17. The Muon g-2 experiment at Fermilab

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chapelain, Antoine

    The upcoming Fermilab E989 experiment will measure the muon anomalous magnetic moment aμ. This measurement is motivated by the previous measurement performed in 2001 by the BNL E821 experiment that reported a 3-4 standard deviation discrepancy between the measured value and the Standard Model prediction. The new measurement at Fermilab aims to improve the precision by a factor of four reducing the total uncertainty from 540 parts per billion (BNL E821) to 140 parts per billion (Fermilab E989). This paper gives the status of the experiment.

  18. The Muon g-2 experiment at Fermilab

    NASA Astrophysics Data System (ADS)

    Chapelain, Antoine

    2017-03-01

    The upcoming Fermilab E989 experiment will measure the muon anomalous magnetic moment aμ. This measurement is motivated by the previous measurement performed in 2001 by the BNL E821 experiment that reported a 3-4 standard deviation discrepancy between the measured value and the Standard Model prediction. The new measurement at Fermilab aims to improve the precision by a factor of four reducing the total uncertainty from 540 parts per billion (BNL E821) to 140 parts per billion (Fermilab E989). This paper gives the status of the experiment.

  19. Ultraviolet Radiation Dose National Standard of México

    NASA Astrophysics Data System (ADS)

    Cardoso, R.; Rosas, E.

    2006-09-01

    We present the Ultraviolet (UV) Radiation Dose National Standard for México. The establishment of this measurement reference at Centro Nacional de Metrología (CENAM) eliminates the need of contacting foreign suppliers in the search for traceability towards the SI units when calibrating instruments at 365 nm. Further more, the UV Radiation Dose National Standard constitutes a highly accurate and reliable source for the UV radiation dose measurements performed in medical and cosmetic treatments as in the the food and pharmaceutics disinfection processes, among other.

  20. Affordable measurement of human total energy expenditure and body composition using one-tenth dose doubly labelled water.

    PubMed

    Mann, D V; Ho, C S; Critchley, L; Fok, B S P; Pang, E W H; Lam, C W K; Hjelm, N M

    2007-05-01

    The doubly labelled water (DLW) method is the technique of choice for measurement of free-living total energy expenditure (TEE) in humans. A major constraint on the clinical applicability of the method has been the expense of the (18)O isotope. We have used a reduced-dose (one-tenth of the currently recommended standard dose) of DLW for the measurement of TEE and body composition in nine healthy adult male volunteers. TEE measured by reduced-dose DLW was positively correlated with resting energy expenditure measured by metabolic cart (r=0.87, P<0.01). Isotope-derived fat mass and body mass index were strongly correlated (r=0.86, P<0.01). In four subjects in whom we performed a complementary evaluation using standard-dose isotope enrichment, the TEE measurements were satisfactorily comparable (mean+/-s.d.: reduced dose 2586+/-155 kcal/day vs standard dose 2843+/-321 kcal/day; mean difference 257+/-265 kcal/day). These data indicate that DLW measurements of human energy expenditure and body composition can be performed at a substantially reduced dose (and cost) of isotope enrichment than is currently employed.

  1. Analytically exploiting noise correlations inside the feedback loop to improve locked-oscillator performance.

    PubMed

    Sastrawan, J; Jones, C; Akhalwaya, I; Uys, H; Biercuk, M J

    2016-08-01

    We introduce concepts from optimal estimation to the stabilization of precision frequency standards limited by noisy local oscillators. We develop a theoretical framework casting various measures for frequency standard variance in terms of frequency-domain transfer functions, capturing the effects of feedback stabilization via a time series of Ramsey measurements. Using this framework, we introduce an optimized hybrid predictive feedforward measurement protocol that employs results from multiple past measurements and transfer-function-based calculations of measurement covariance to improve the accuracy of corrections within the feedback loop. In the presence of common non-Markovian noise processes these measurements will be correlated in a calculable manner, providing a means to capture the stochastic evolution of the local oscillator frequency during the measurement cycle. We present analytic calculations and numerical simulations of oscillator performance under competing feedback schemes and demonstrate benefits in both correction accuracy and long-term oscillator stability using hybrid feedforward. Simulations verify that in the presence of uncompensated dead time and noise with significant spectral weight near the inverse cycle time predictive feedforward outperforms traditional feedback, providing a path towards developing a class of stabilization software routines for frequency standards limited by noisy local oscillators.

  2. The impact of statistical adjustment on conditional standard errors of measurement in the assessment of physician communication skills.

    PubMed

    Raymond, Mark R; Clauser, Brian E; Furman, Gail E

    2010-10-01

    The use of standardized patients to assess communication skills is now an essential part of assessing a physician's readiness for practice. To improve the reliability of communication scores, it has become increasingly common in recent years to use statistical models to adjust ratings provided by standardized patients. This study employed ordinary least squares regression to adjust ratings, and then used generalizability theory to evaluate the impact of these adjustments on score reliability and the overall standard error of measurement. In addition, conditional standard errors of measurement were computed for both observed and adjusted scores to determine whether the improvements in measurement precision were uniform across the score distribution. Results indicated that measurement was generally less precise for communication ratings toward the lower end of the score distribution; and the improvement in measurement precision afforded by statistical modeling varied slightly across the score distribution such that the most improvement occurred in the upper-middle range of the score scale. Possible reasons for these patterns in measurement precision are discussed, as are the limitations of the statistical models used for adjusting performance ratings.

  3. 47 CFR 36.2 - Fundamental principles underlying procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...” measurements, measurements of use are (i) determined for telecommunications plant or for work performed by operating forces on a unit basis (e.g., conversation-minute-kilometers per message, weighted standard work seconds per call) in studies of traffic handled or work performed during a representative period for all...

  4. Managing for Results--Linking Performance Measures and Budgets.

    ERIC Educational Resources Information Center

    McGee, William L.; Fountain, James R., Jr.

    1995-01-01

    The Government Accounting Standards Board notion of service efforts and accomplishments reporting is one step in a process of managing for results that includes strategic planning, development and use of performance measures of managing ongoing programs, and outputs to budgetary appropriation. Reports a trial application to one school district.…

  5. Identification of Commercial Items Risk Factors

    DTIC Science & Technology

    2003-03-01

    performance measures, vendors availability of support, testing and managing organizational change . 1. Process Risk Factor: Commercial Standards Military...support, testing and managing organizational change . C. ASSESSING RESULTS Completing the questions and assessing/compiling the results should help...to performance measures, vendors availability of support, testing and managing organizational change . SECTION I Service

  6. Assessing Instructor Performance: Best Practices from the Intelligence Community

    ERIC Educational Resources Information Center

    Hennessey, Megan J.

    2017-01-01

    Throughout continuing education focusing on the adult learner, standardized and sometimes even effective measures of instructor performance have remained elusive. As Smith (2012) stated, "Teaching practice cannot be measured according to lists of competencies or techniques, it cannot be safeguarded by a collection of prescriptions for good…

  7. 76 FR 76541 - Medicare Program; Availability of Medicare Data for Performance Measurement

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-07

    ... Centers for Medicare & Medicaid Services 42 CFR Part 401 Medicare Program; Availability of Medicare Data...; Availability of Medicare Data for Performance Measurement AGENCY: Centers for Medicare & Medicaid Services (CMS... regarding the release and use of standardized extracts of Medicare claims data for qualified entities to...

  8. The Consequences of Using One Assessment System to Pursue Two Objectives

    ERIC Educational Resources Information Center

    Neal, Derek

    2013-01-01

    Education officials often use one assessment system both to create measures of student achievement and to create performance metrics for educators. However, modern standardized testing systems are not designed to produce performance metrics for teachers or principals. They are designed to produce reliable measures of individual student achievement…

  9. Flight performance measurement utilizing a figure of merit (FOM)

    NASA Technical Reports Server (NTRS)

    Mosier, Kathleen L.; Zacharias, Greg L.

    1993-01-01

    One of the goals of the NASA Strategic Behavior/Workload Management Program is to develop standardized procedures for constructing figures of merit (FOMs) that describe minimal criteria for flight task performance, as well as summarize overall performance quality. Such a measure could be utilized for evaluating flight crew performance, for assessing the effectiveness of new equipment or technological innovations, or for measuring performance at a particular airport. In this report, we describe the initial phases in the creation of a FOM to be employed in examining crew performance in NASA-Ames Air Ground Compatibility and Strategic Behavior/Workload Management programs.

  10. Comparison between the triglycerides standardization of routine methods used in Japan and the chromotropic acid reference measurement procedure used by the CDC Lipid Standardization Programme.

    PubMed

    Nakamura, Masakazu; Iso, Hiroyasu; Kitamura, Akihiko; Imano, Hironori; Noda, Hiroyuki; Kiyama, Masahiko; Sato, Shinichi; Yamagishi, Kazumasa; Nishimura, Kunihiro; Nakai, Michikazu; Vesper, Hubert W; Teramoto, Tamio; Miyamoto, Yoshihiro

    2016-11-01

    Background The US Centers for Disease Control and Prevention ensured adequate performance of the routine triglycerides methods used in Japan by a chromotropic acid reference measurement procedure used by the Centers for Disease Control and Prevention lipid standardization programme as a reference point. We examined standardized data to clarify the performance of routine triglycerides methods. Methods The two routine triglycerides methods were the fluorometric method of Kessler and Lederer and the enzymatic method. The methods were standardized using 495 Centers for Disease Control and Prevention reference pools with 98 different concentrations ranging between 0.37 and 5.15 mmol/L in 141 survey runs. The triglycerides criteria for laboratories which perform triglycerides analyses are used: accuracy, as bias ≤5% from the Centers for Disease Control and Prevention reference value and precision, as measured by CV, ≤5%. Results The correlation of the bias of both methods to the Centers for Disease Control and Prevention reference method was: y (%bias) = 0.516 × (Centers for Disease Control and Prevention reference value) -1.292 ( n = 495, R 2  = 0.018). Triglycerides bias at medical decision points of 1.13, 1.69 and 2.26 mmol/L was -0.71%, -0.42% and -0.13%, respectively. For the combined precision, the equation y (CV) = -0.398 × (triglycerides value) + 1.797 ( n = 495, R 2  = 0.081) was used. Precision was 1.35%, 1.12% and 0.90%, respectively. It was shown that triglycerides measurements at Osaka were stable for 36 years. Conclusions The epidemiologic laboratory in Japan met acceptable accuracy goals for 88.7% of all samples, and met acceptable precision goals for 97.8% of all samples measured through the Centers for Disease Control and Prevention lipid standardization programme and demonstrated stable results for an extended period of time.

  11. Comparison between the triglycerides standardization of routine methods used in Japan and the chromotropic acid reference measurement procedure used by the CDC Lipid Standardization Programme

    PubMed Central

    Nakamura, Masakazu; Iso, Hiroyasu; Kitamura, Akihiko; Imano, Hironori; Noda, Hiroyuki; Kiyama, Masahiko; Sato, Shinichi; Yamagishi, Kazumasa; Nishimura, Kunihiro; Nakai, Michikazu; Vesper, Hubert W; Teramoto, Tamio; Miyamoto, Yoshihiro

    2017-01-01

    Background The US Centers for Disease Control and Prevention ensured adequate performance of the routine triglycerides methods used in Japan by a chromotropic acid reference measurement procedure used by the Centers for Disease Control and Prevention lipid standardization programme as a reference point. We examined standardized data to clarify the performance of routine triglycerides methods. Methods The two routine triglycerides methods were the fluorometric method of Kessler and Lederer and the enzymatic method. The methods were standardized using 495 Centers for Disease Control and Prevention reference pools with 98 different concentrations ranging between 0.37 and 5.15 mmol/L in 141 survey runs. The triglycerides criteria for laboratories which perform triglycerides analyses are used: accuracy, as bias ≤5% from the Centers for Disease Control and Prevention reference value and precision, as measured by CV, ≤5%. Results The correlation of the bias of both methods to the Centers for Disease Control and Prevention reference method was: y (%bias) = 0.516 × (Centers for Disease Control and Prevention reference value) −1.292 (n = 495, R2 = 0.018). Triglycerides bias at medical decision points of 1.13, 1.69 and 2.26 mmol/L was −0.71%, −0.42% and −0.13%, respectively. For the combined precision, the equation y (CV) = −0.398 × (triglycerides value) + 1.797 (n = 495, R2 = 0.081) was used. Precision was 1.35%, 1.12% and 0.90%, respectively. It was shown that triglycerides measurements at Osaka were stable for 36 years. Conclusions The epidemiologic laboratory in Japan met acceptable accuracy goals for 88.7% of all samples, and met acceptable precision goals for 97.8% of all samples measured through the Centers for Disease Control and Prevention lipid standardization programme and demonstrated stable results for an extended period of time. PMID:26680645

  12. Oral Reading Fluency and Maze Measures as Predictors of Performance on North Carolina End-of-Grade Assessment of Reading Comprehension

    ERIC Educational Resources Information Center

    Galloway, Tara Watkins

    2010-01-01

    Current legislation (IDEA, 2004; NCLB, 2001) mandates all students, including students with disabilities, demonstrate progress toward the same standards. However, students continue to struggle with attainment of statewide academic standards as measured by high-stakes assessment. The purpose of the current study was to examine the degree that…

  13. Flow Control and Measurement in Electric Propulsion Systems: Towards an AIAA Reference Standard

    DTIC Science & Technology

    2013-10-01

    the spacecraft sensors, although some improvement can be made by averaging several measurements together. 3. Thermal Mass Gauging Thermal Mass...flow controllers (MFCs) to measure and control propellant into EP devices. To determine several key thruster performance parameters with a low level...the specified time interval may not be known. A first recourse is to perform several measurements and examine the linearity. In cases where the

  14. Prognostic score–based balance measures for propensity score methods in comparative effectiveness research

    PubMed Central

    Stuart, Elizabeth A.; Lee, Brian K.; Leacy, Finbarr P.

    2013-01-01

    Objective Examining covariate balance is the prescribed method for determining when propensity score methods are successful at reducing bias. This study assessed the performance of various balance measures, including a proposed balance measure based on the prognostic score (also known as the disease-risk score), to determine which balance measures best correlate with bias in the treatment effect estimate. Study Design and Setting The correlations of multiple common balance measures with bias in the treatment effect estimate produced by weighting by the odds, subclassification on the propensity score, and full matching on the propensity score were calculated. Simulated data were used, based on realistic data settings. Settings included both continuous and binary covariates and continuous covariates only. Results The standardized mean difference in prognostic scores, the mean standardized mean difference, and the mean t-statistic all had high correlations with bias in the effect estimate. Overall, prognostic scores displayed the highest correlations of all the balance measures considered. Prognostic score measure performance was generally not affected by model misspecification and performed well under a variety of scenarios. Conclusion Researchers should consider using prognostic score–based balance measures for assessing the performance of propensity score methods for reducing bias in non-experimental studies. PMID:23849158

  15. Evaluation of the 235 U resonance parameters to fit the standard recommended values

    DOE PAGES

    Leal, Luiz; Noguere, Gilles; Paradela, Carlos; ...

    2017-09-13

    A great deal of effort has been dedicated to the revision of the standard values in connection with the neutron interaction for some actinides. While standard data compilation are available for decades nuclear data evaluations included in existing nuclear data libraries (ENDF, JEFF, JENDL, etc.) do not follow the standard recommended values. Indeed, the majority of evaluations for major actinides do not conform to the standards whatsoever. In particular, for the n + 235U interaction the only value in agreement with the standard is the thermal fission cross section. We performed a resonance re-evaluation of the n + 235U interactionmore » in order to address the issues regarding standard values in the energy range from 10-5 eV to 2250 eV. Recently, 235U fission cross-section measurements have been performed at the CERN Neutron Time-o-Flight facility (TOF), known as n_TOF, in the energy range from 0.7 eV to 10 keV. The data were normalized according to the recommended standard of the fission integral in the energy range 7.8 eV to 11 eV. As a result, the n_TOF averaged fission cross sections above 100 eV are in good agreement with the standard recommended values. The n_TOF data were included in the 235U resonance analysis that was performed with the code SAMMY. In addition to the average standard values related to the fission cross section, standard thermal values for fission, capture, and elastic cross sections were also included in the evaluation. Our paper presents the procedure used for re-evaluating the 235U resonance parameters including the recommended standard values as well as new cross section measurements.« less

  16. Evaluation of the 235 U resonance parameters to fit the standard recommended values

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leal, Luiz; Noguere, Gilles; Paradela, Carlos

    A great deal of effort has been dedicated to the revision of the standard values in connection with the neutron interaction for some actinides. While standard data compilation are available for decades nuclear data evaluations included in existing nuclear data libraries (ENDF, JEFF, JENDL, etc.) do not follow the standard recommended values. Indeed, the majority of evaluations for major actinides do not conform to the standards whatsoever. In particular, for the n + 235U interaction the only value in agreement with the standard is the thermal fission cross section. We performed a resonance re-evaluation of the n + 235U interactionmore » in order to address the issues regarding standard values in the energy range from 10-5 eV to 2250 eV. Recently, 235U fission cross-section measurements have been performed at the CERN Neutron Time-o-Flight facility (TOF), known as n_TOF, in the energy range from 0.7 eV to 10 keV. The data were normalized according to the recommended standard of the fission integral in the energy range 7.8 eV to 11 eV. As a result, the n_TOF averaged fission cross sections above 100 eV are in good agreement with the standard recommended values. The n_TOF data were included in the 235U resonance analysis that was performed with the code SAMMY. In addition to the average standard values related to the fission cross section, standard thermal values for fission, capture, and elastic cross sections were also included in the evaluation. Our paper presents the procedure used for re-evaluating the 235U resonance parameters including the recommended standard values as well as new cross section measurements.« less

  17. Evaluation of the 235U resonance parameters to fit the standard recommended values

    NASA Astrophysics Data System (ADS)

    Leal, Luiz; Noguere, Gilles; Paradela, Carlos; Durán, Ignacio; Tassan-Got, Laurent; Danon, Yaron; Jandel, Marian

    2017-09-01

    A great deal of effort has been dedicated to the revision of the standard values in connection with the neutron interaction for some actinides. While standard data compilation are available for decades nuclear data evaluations included in existing nuclear data libraries (ENDF, JEFF, JENDL, etc.) do not follow the standard recommended values. Indeed, the majority of evaluations for major actinides do not conform to the standards whatsoever. In particular, for the n + 235U interaction the only value in agreement with the standard is the thermal fission cross section. A resonance re-evaluation of the n + 235U interaction has been performed to address the issues regarding standard values in the energy range from 10-5 eV to 2250 eV. Recently, 235U fission cross-section measurements have been performed at the CERN Neutron Time-of-Flight facility (TOF), known as n_TOF, in the energy range from 0.7 eV to 10 keV. The data were normalized according to the recommended standard of the fission integral in the energy range 7.8 eV to 11 eV. As a result, the n_TOF averaged fission cross sections above 100 eV are in good agreement with the standard recommended values. The n_TOF data were included in the 235U resonance analysis that was performed with the code SAMMY. In addition to the average standard values related to the fission cross section, standard thermal values for fission, capture, and elastic cross sections were also included in the evaluation. This paper presents the procedure used for re-evaluating the 235U resonance parameters including the recommended standard values as well as new cross section measurements.

  18. 48 CFR 37.601 - General.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... a performance work statement or a statement of objectives (see 37.602). (b) Performance-based contracts for services shall include— (1) A performance work statement (PWS); (2) Measurable performance standards (i.e., in terms of quality, timeliness, quantity, etc.) and the method of assessing contractor...

  19. 48 CFR 37.601 - General.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... a performance work statement or a statement of objectives (see 37.602). (b) Performance-based contracts for services shall include— (1) A performance work statement (PWS); (2) Measurable performance standards (i.e., in terms of quality, timeliness, quantity, etc.) and the method of assessing contractor...

  20. 48 CFR 37.601 - General.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... a performance work statement or a statement of objectives (see 37.602). (b) Performance-based contracts for services shall include— (1) A performance work statement (PWS); (2) Measurable performance standards (i.e., in terms of quality, timeliness, quantity, etc.) and the method of assessing contractor...

  1. Alternatives to Standardized Tests in Reading Education: Cognitive Styles and Informal Measures.

    ERIC Educational Resources Information Center

    Scales, Alice M.

    1987-01-01

    Although cognitive style affects test results, students of various cognitive styles are expected to perform equally well on standardized tests. Informal tests seem to be better for both impulsive and reflective style students. Perhaps a combination of standardized and informal testing is appropriate for making educational decisions about students.…

  2. Evaluating Public Libraries Using Standard Scores: The Library Quotient.

    ERIC Educational Resources Information Center

    O'Connor, Daniel O.

    1982-01-01

    Describes a method for assessing the performance of public libraries using a standardized scoring system and provides an analysis of public library data from New Jersey as an example. Library standards and the derivation of measurement ratios are also discussed. A 33-item bibliography and three data tables are included. (JL)

  3. Medical decision-making capacity in patients with malignant glioma.

    PubMed

    Triebel, Kristen L; Martin, Roy C; Nabors, Louis B; Marson, Daniel C

    2009-12-15

    Patients with malignant glioma (MG) must make ongoing medical treatment decisions concerning a progressive disease that erodes cognition. We prospectively assessed medical decision-making capacity (MDC) in patients with MG using a standardized psychometric instrument. Participants were 22 healthy controls and 26 patients with histologically verified MG. Group performance was compared on the Capacity to Consent to Treatment Instrument (CCTI), a psychometric measure of MDC incorporating 4 standards (choice, understanding, reasoning, and appreciation), and on neuropsychological and demographic variables. Capacity outcomes (capable, marginally capable, or incapable) on the CCTI standards were identified for the MG group. Within the MG group, scores on demographic, clinical, and neuropsychological variables were correlated with scores on each CCTI standard, and significant bivariate correlates were subsequently entered into exploratory stepwise regression analyses to identify multivariate cognitive predictors of the CCTI standards. Patients with MG performed significantly below controls on consent standards of understanding and reasoning, and showed a trend on appreciation. Relative to controls, more than 50% of the patients with MG demonstrated capacity compromise (marginally capable or incapable outcomes) in MDC. In the MG group, cognitive measures of verbal acquisition/recall and, to a lesser extent, semantic fluency predicted performance on the appreciation, reasoning, and understanding standards. Karnofsky score was also associated with CCTI performance. Soon after diagnosis, patients with malignant glioma (MG) have impaired capacity to make treatment decisions relative to controls. Medical decision-making capacity (MDC) impairment in MG seems to be primarily related to the effects of short-term verbal memory deficits. Ongoing assessment of MDC in patients with MG is strongly recommended.

  4. Bivariate random-effects meta-analysis models for diagnostic test accuracy studies using arcsine-based transformations.

    PubMed

    Negeri, Zelalem F; Shaikh, Mateen; Beyene, Joseph

    2018-05-11

    Diagnostic or screening tests are widely used in medical fields to classify patients according to their disease status. Several statistical models for meta-analysis of diagnostic test accuracy studies have been developed to synthesize test sensitivity and specificity of a diagnostic test of interest. Because of the correlation between test sensitivity and specificity, modeling the two measures using a bivariate model is recommended. In this paper, we extend the current standard bivariate linear mixed model (LMM) by proposing two variance-stabilizing transformations: the arcsine square root and the Freeman-Tukey double arcsine transformation. We compared the performance of the proposed methods with the standard method through simulations using several performance measures. The simulation results showed that our proposed methods performed better than the standard LMM in terms of bias, root mean square error, and coverage probability in most of the scenarios, even when data were generated assuming the standard LMM. We also illustrated the methods using two real data sets. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. B physics and Quarkonia in CMS

    NASA Astrophysics Data System (ADS)

    Fiorendi, Sara

    2017-12-01

    The heavy-flavor sector offers the opportunity to perform indirect tests of beyond the Standard Model physics through precision measurements and of quantum chromodynamics (QCD) through particle production studies. A review of recent measurements on heavy flavors from the CMS experiment is presented. Results are based on data collected during LHC Run I and Run II and include measurements of heavy flavor production and properties, rare decays, CP violation, exotic and standard quarkonia. Warning, no authors found for 2017EPJWC.16407006.

  6. Linear model correction: A method for transferring a near-infrared multivariate calibration model without standard samples.

    PubMed

    Liu, Yan; Cai, Wensheng; Shao, Xueguang

    2016-12-05

    Calibration transfer is essential for practical applications of near infrared (NIR) spectroscopy because the measurements of the spectra may be performed on different instruments and the difference between the instruments must be corrected. For most of calibration transfer methods, standard samples are necessary to construct the transfer model using the spectra of the samples measured on two instruments, named as master and slave instrument, respectively. In this work, a method named as linear model correction (LMC) is proposed for calibration transfer without standard samples. The method is based on the fact that, for the samples with similar physical and chemical properties, the spectra measured on different instruments are linearly correlated. The fact makes the coefficients of the linear models constructed by the spectra measured on different instruments are similar in profile. Therefore, by using the constrained optimization method, the coefficients of the master model can be transferred into that of the slave model with a few spectra measured on slave instrument. Two NIR datasets of corn and plant leaf samples measured with different instruments are used to test the performance of the method. The results show that, for both the datasets, the spectra can be correctly predicted using the transferred partial least squares (PLS) models. Because standard samples are not necessary in the method, it may be more useful in practical uses. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. 30 CFR 819.21 - Auger mining: Protection of underground mining.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., DEPARTMENT OF THE INTERIOR PERMANENT PROGRAM PERFORMANCE STANDARDS SPECIAL PERMANENT PROGRAM PERFORMANCE... closer than 500 feet (measured horizontally) to any abandoned or active underground mine workings, except...

  8. 40 CFR 432.105 - New source performance standards (NSPS).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Standards [NSPS] Regulatedparameter Maximum daily Maximum monthly avg. Ammonia (as N) 1 0.14 0.07 BOD 5 1 0... maximum monthly average limitation. 4 May be measured as hexane extractable material (HEM). 5 mg/L (ppm...

  9. 40 CFR 432.105 - New source performance standards (NSPS).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Standards [NSPS] Regulatedparameter Maximum daily Maximum monthly avg. Ammonia (as N) 1 0.14 0.07 BOD 5 1 0... maximum monthly average limitation. 4 May be measured as hexane extractable material (HEM). 5 mg/L (ppm...

  10. The Score-Boosting Game.

    ERIC Educational Resources Information Center

    Popham, W. James

    2000-01-01

    Teachers everywhere are playing the score-boosting game to raise scores on mandated standardized achievement tests, although five nationally recognized assessments compare student performance instead of measuring classroom learning. Since curriculum standards are often vague and misaligned with assessments, teachers sprinkle instruction with…

  11. Measurement of global functional performance in patients with rheumatoid arthritis using rheumatology function tests

    PubMed Central

    Escalante, Agustín; Haas, Roy W; del Rincón, Inmaculada

    2004-01-01

    Outcome assessment in patients with rheumatoid arthritis (RA) includes measurement of physical function. We derived a scale to quantify global physical function in RA, using three performance-based rheumatology function tests (RFTs). We measured grip strength, walking velocity, and shirt button speed in consecutive RA patients attending scheduled appointments at six rheumatology clinics, repeating these measurements after a median interval of 1 year. We extracted the underlying latent variable using principal component factor analysis. We used the Bayesian information criterion to assess the global physical function scale's cross-sectional fit to criterion standards. The criteria were joint tenderness, swelling, and deformity, pain, physical disability, current work status, and vital status at 6 years after study enrolment. We computed Guyatt's responsiveness statistic for improvement according to the American College of Rheumatology (ACR) definition. Baseline functional performance data were available for 777 patients, and follow-up data were available for 681. Mean ± standard deviation for each RFT at baseline were: grip strength, 14 ± 10 kg; walking velocity, 194 ± 82 ft/min; and shirt button speed, 7.1 ± 3.8 buttons/min. Grip strength and walking velocity departed significantly from normality. The three RFTs loaded strongly on a single factor that explained ≥70% of their combined variance. We rescaled the factor to vary from 0 to 100. Its mean ± standard deviation was 41 ± 20, with a normal distribution. The new global scale had a stronger fit than the primary RFT to most of the criterion standards. It correlated more strongly with physical disability at follow-up and was more responsive to improvement defined according to the ACR20 and ACR50 definitions. We conclude that a performance-based physical function scale extracted from three RFTs has acceptable distributional and measurement properties and is responsive to clinically meaningful change. It provides a parsimonious scale to measure global physical function in RA. PMID:15225367

  12. Toward a New Evaluation of Neutron Standards

    DOE PAGES

    Carlson, Allan D.; Pronyaev, Vladimir G.; Capote, Roberto; ...

    2016-02-03

    Measurements related to neutron cross section standards and certain prompt neutron fission spectra are being evaluated. In addition to the standard cross sections, investigations of reference data that are not as well known as the standards are being considered. We discuss procedures and codes for performing this work. A number of libraries will use the results of this standards evaluation for new versions of their libraries. Most of these data have applications in neutron dosimetry.

  13. Developing Performance Measures for Manned-Unmanned Teaming Skills

    DTIC Science & Technology

    2015-02-01

    Moves aircraft to safe area Utilize standardized radio communication and signal operating procedures Perform BDA Utilize Standard report formats...UAS does not conduct BDA ; assumes target is destroyed without verification UAS evaluates target; reports BDA to engaging aircraft (or...ground unit) after prompting UAS evaluates target; proactively reports BDA to engaging aircraft (or ground unit) 1 2 3 4 5 1 2 3 4 5 B

  14. Standardized Six-Step Approach to the Performance of the Focused Basic Obstetric Ultrasound Examination.

    PubMed

    Abuhamad, Alfred; Zhao, Yili; Abuhamad, Sharon; Sinkovskaya, Elena; Rao, Rashmi; Kanaan, Camille; Platt, Lawrence

    2016-01-01

    This study aims to validate the feasibility and accuracy of a new standardized six-step approach to the performance of the focused basic obstetric ultrasound examination, and compare the new approach to the regular approach performed in the scheduled obstetric ultrasound examination. A new standardized six-step approach to the performance of the focused basic obstetric ultrasound examination, to evaluate fetal presentation, fetal cardiac activity, presence of multiple pregnancy, placental localization, amniotic fluid volume evaluation, and biometric measurements, was prospectively performed on 100 pregnant women between 18(+0) and 27(+6) weeks of gestation and another 100 pregnant women between 28(+0) and 36(+6) weeks of gestation. The agreement of findings for each of the six steps of the standardized six-step approach was evaluated against the regular approach. In all ultrasound examinations performed, substantial to perfect agreement (Kappa value between 0.64 and 1.00) was observed between the new standardized six-step approach and the regular approach. The new standardized six-step approach to the focused basic obstetric ultrasound examination can be performed successfully and accurately between 18(+0) and 36(+6) weeks of gestation. This standardized approach can be of significant benefit to limited resource settings and in point of care obstetric ultrasound applications. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  15. Estimating equations for glomerular filtration rate in the era of creatinine standardization: a systematic review.

    PubMed

    Earley, Amy; Miskulin, Dana; Lamb, Edmund J; Levey, Andrew S; Uhlig, Katrin

    2012-06-05

    Clinical laboratories are increasingly reporting estimated glomerular filtration rate (GFR) by using serum creatinine assays traceable to a standard reference material. To review the performance of GFR estimating equations to inform the selection of a single equation by laboratories and the interpretation of estimated GFR by clinicians. A systematic search of MEDLINE, without language restriction, between 1999 and 21 October 2011. Cross-sectional studies in adults that compared the performance of 2 or more creatinine-based GFR estimating equations with a reference GFR measurement. Eligible equations were derived or reexpressed and validated by using creatinine measurements traceable to the standard reference material. Reviewers extracted data on study population characteristics, measured GFR, creatinine assay, and equation performance. Eligible studies compared the MDRD (Modification of Diet in Renal Disease) Study and CKD-EPI (Chronic Kidney Disease Epidemiology Collaboration) equations or modifications thereof. In 12 studies in North America, Europe, and Australia, the CKD-EPI equation performed better at higher GFRs (approximately >60 mL/min per 1.73 m(2)) and the MDRD Study equation performed better at lower GFRs. In 5 of 8 studies in Asia and Africa, the equations were modified to improve their performance by adding a coefficient derived in the local population or removing a coefficient. Methods of GFR measurement and study populations were heterogeneous. Neither the CKD-EPI nor the MDRD Study equation is optimal for all populations and GFR ranges. Using a single equation for reporting requires a tradeoff to optimize performance at either higher or lower GFR ranges. A general practice and public health perspective favors the CKD-EPI equation. Kidney Disease: Improving Global Outcomes.

  16. Findings and Preliminary Recommendations from the Michigan State and Indiana University Research Study of Value-Added Models to Evaluate Teacher Performance

    ERIC Educational Resources Information Center

    Guarino, Cassandra M.

    2013-01-01

    The push for accountability in public schooling has extended to the measurement of teacher performance, accelerated by federal efforts through Race to the Top. Currently, a large number of states and districts across the country are computing measures of teacher performance based on the standardized test scores of their students and using them in…

  17. Payment models to support population health management.

    PubMed

    Huerta, Timothy R; Hefner, Jennifer L; McAlearney, Ann Scheck

    2014-01-01

    To survey the policy-driven financial controls currently being used to drive physician change in the care of populations. This paper offers a review of current health care payment models and discusses the impact of each on the potential success of PHM initiatives. We present the benefits of a multi-part model, combining visit-based fee-for-service reimbursement with a monthly "care coordination payment" and a performance-based payment system. A multi-part model removes volume-based incentives and promotes efficiency. However, it is predicated on a pay-for-performance framework that requires standardized measurement. Application of this model is limited due to the current lack of standardized measurement of quality goals that are linked to payment incentives. Financial models dictated by health system payers are inextricably linked to the organization and management of health care. There is a need for better measurements and realistic targets as part of a comprehensive system of measurement assessment that focuses on practice redesign, with the goal of standardizing measurement of the structure and process of redesign. Payment reform is a necessary component of an accurate measure of the associations between practice transformation and outcomes important to both patients and society.

  18. Development of an Online Toolkit for Measuring Performance in Health Emergency Response Exercises.

    PubMed

    Agboola, Foluso; Bernard, Dorothy; Savoia, Elena; Biddinger, Paul D

    2015-10-01

    Exercises that simulate emergency scenarios are accepted widely as an essential component of a robust Emergency Preparedness program. Unfortunately, the variability in the quality of the exercises conducted, and the lack of standardized processes to measure performance, has limited the value of exercises in measuring preparedness. In order to help health organizations improve the quality and standardization of the performance data they collect during simulated emergencies, a model online exercise evaluation toolkit was developed using performance measures tested in over 60 Emergency Preparedness exercises. The exercise evaluation toolkit contains three major components: (1) a database of measures that can be used to assess performance during an emergency response exercise; (2) a standardized data collection tool (form); and (3) a program that populates the data collection tool with the measures that have been selected by the user from the database. The evaluation toolkit was pilot tested from January through September 2014 in collaboration with 14 partnering organizations representing 10 public health agencies and four health care agencies from eight states across the US. Exercise planners from the partnering organizations were asked to use the toolkit for their exercise evaluation process and were interviewed to provide feedback on the use of the toolkit, the generated evaluation tool, and the usefulness of the data being gathered for the development of the exercise after-action report. Ninety-three percent (93%) of exercise planners reported that they found the online database of performance measures appropriate for the creation of exercise evaluation forms, and they stated that they would use it again for future exercises. Seventy-two percent (72%) liked the exercise evaluation form that was generated from the toolkit, and 93% reported that the data collected by the use of the evaluation form were useful in gauging their organization's performance during the exercise. Seventy-nine percent (79%) of exercise planners preferred the evaluation form generated by the toolkit to other forms of evaluations. Results of this project show that users found the newly developed toolkit to be user friendly and more relevant to measurement of specific public health and health care capabilities than other tools currently available. The developed toolkit may contribute to the further advancement of developing a valid approach to exercise performance measurement.

  19. 20 CFR 416.1040 - General.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... acceptable. Also, the standards are designed to improve overall State agency performance in the disability... efficient manner. We measure the performance of a State agency in two areas—processing time and quality of...

  20. 20 CFR 404.1640 - General.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... acceptable. Also, the standards are designed to improve overall State agency performance in the disability... efficient manner. We measure the performance of a State agency in two areas—processing time and quality of...

  1. 45 CFR 305.61 - Penalty for failure to meet IV-D requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... HEALTH AND HUMAN SERVICES PROGRAM PERFORMANCE MEASURES, STANDARDS, FINANCIAL INCENTIVES, AND PENALTIES § 305.61 Penalty for failure to meet IV-D requirements. (a) A State will be subject to a financial... order establishment and current collections performance measures as set forth in § 305.40 of this part...

  2. Perkins Core Performance Measures: Results and Targets, 2001-2002.

    ERIC Educational Resources Information Center

    McHewitt, Earl R.; Taylor, Garry

    This report addresses the Virginia Community College System's (VCCS) core performance standards and measures for the years 2001-2002. There are four core indicators through which the VCCS is assessed. They are the following: (1) student attainment including academic and technical skills; (2) completion/graduation rate using first time, full-time…

  3. A proteomics performance standard to support measurement quality in proteomics.

    PubMed

    Beasley-Green, Ashley; Bunk, David; Rudnick, Paul; Kilpatrick, Lisa; Phinney, Karen

    2012-04-01

    The emergence of MS-based proteomic platforms as a prominent technology utilized in biochemical and biomedical research has increased the need for high-quality MS measurements. To address this need, National Institute of Standards and Technology (NIST) reference material (RM) 8323 yeast protein extract is introduced as a proteomics quality control material for benchmarking the preanalytical and analytical performance of proteomics-based experimental workflows. RM 8323 yeast protein extract is based upon the well-characterized eukaryote Saccharomyces cerevisiae and can be utilized in the design and optimization of proteomics-based methodologies from sample preparation to data analysis. To demonstrate its utility as a proteomics quality control material, we coupled LC-MS/MS measurements of RM 8323 with the NIST MS Quality Control (MSQC) performance metrics to quantitatively assess the LC-MS/MS instrumentation parameters that influence measurement accuracy, repeatability, and reproducibility. Due to the complexity of the yeast proteome, we also demonstrate how NIST RM 8323, along with the NIST MSQC performance metrics, can be used in the evaluation and optimization of proteomics-based sample preparation methods. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. The Ca(2+)-EDTA chelation as standard reaction to validate Isothermal Titration Calorimeter measurements (ITC).

    PubMed

    Ràfols, Clara; Bosch, Elisabeth; Barbas, Rafael; Prohens, Rafel

    2016-07-01

    A study about the suitability of the chelation reaction of Ca(2+)with ethylenediaminetetraacetic acid (EDTA) as a validation standard for Isothermal Titration Calorimeter measurements has been performed exploring the common experimental variables (buffer, pH, ionic strength and temperature). Results obtained in a variety of experimental conditions have been amended according to the side reactions involved in the main process and to the experimental ionic strength and, finally, validated by contrast with the potentiometric reference values. It is demonstrated that the chelation reaction performed in acetate buffer 0.1M and 25°C shows accurate and precise results and it is robust enough to be adopted as a standard calibration process. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Historical review of lung counting efficiencies for low energy photon emitters

    DOE PAGES

    Jeffers, Karen L.; Hickman, David P.

    2014-03-01

    This publication reviews the measured efficiency and variability over time of a high purity planar germanium in vivo lung count system for multiple photon energies using increasingly thick overlays with the Lawrence Livermore Torso Phantom. Furthermore, the measured variations in efficiency are compared with the current requirement for in vivo bioassay performance as defined by the American National Standards Institute Standard.

  6. Integrated Information Support System (IISS). Volume 4. IISS System. Part 1. System Requirement Document.

    DTIC Science & Technology

    1985-11-01

    access audit trail. 2. Screen audit trail for unauthorized entries. B.6.3.3 Manage CDX Resources B.6.3.3.1 Measure CDX Performance 1. Keep running...response time B-32 SRD620140000 1 November 1985 -ii I B -3 / I 0 / . ".3 SRD620140000 1 November 1985 4. Audit 1ISS hardware performance (LAN, HOSTS...standards on-line. 7. Assist IISS service specifier and application specifier in implementing standards recommendation. 8. Perform audit of IISS

  7. The short physical performance battery as a predictor of functional capacity after stroke.

    PubMed

    Stookey, Alyssa D; Katzel, Leslie I; Steinbrenner, Gregory; Shaughnessy, Marianne; Ivey, Frederick M

    2014-01-01

    The short physical performance battery is a widely used instrument for quantifying lower extremity function in older adults. However, its utility for predicting endurance-based measures of functional performance that are more difficult to conduct in clinical settings is unknown. An understanding of this could be particularly relevant in mobility impaired stroke survivors, for whom establishing the predictive strength of simpler to perform measures would aid in tracking broader categories of functional disability. This cross-sectional study was conducted to determine whether the short physical performance battery is related to functional measures with a strong endurance component. Functional measures (short physical performance battery, peak aerobic capacity, and 6-minute walk) were obtained and compared for the first time in stroke survivors with hemiparetic gait. Pearson correlation coefficients were used to assess strength of the relationships (α P < .05). Forty-three stroke participants performed a standardized short physical performance battery. Forty-one of the subjects completed a 6-minute walk, and 40 completed a peak treadmill test. Mean short physical performance battery (6.3 ± 2.5 [mean ± SD]), 6-minute walk (242 ± 115 meters), and peak aerobic capacity (17.4 ± 5.4 mL/kg/min) indicated subjects had moderate to severely impaired lower extremity functional performance. The short physical performance battery was related to both 6-minute walk (r = 0.76; P < .0001) and peak fitness (r = 0.52; P < .001). Our results show that the short physical performance battery may be reflective of endurance-based, longer-distance performance measures that would be difficult to perform in standard clinical stroke settings. Additional studies are needed to explore the value of using the short physical performance battery to assess rehabilitation-related functional progression after stroke. Published by Elsevier Inc.

  8. Optimal MEMS device for mobility and zeta potential measurements using DC electrophoresis.

    PubMed

    Karam, Pascal R; Dukhin, Andrei; Pennathur, Sumita

    2017-05-01

    We have developed a novel microchannel geometry that allows us to perform simple DC electrophoresis to measure the electrophoretic mobility and zeta potential of analytes and particles. In standard capillary geometries, mobility measurements using DC fields are difficult to perform. Specifically, measurements in open capillaries require knowledge of the hard to measure and often dynamic wall surface potential. Although measurements in closed capillaries eliminate this requirement, the measurements must be performed at infinitesimally small regions of zero flow where the pressure driven-flow completely cancels the electroosmotic flow (Komagata Planes). Furthermore, applied DC fields lead to electrode polarization, further questioning the reliability and accuracy of the measurement. In contrast, our geometry expands and moves the Komagata planes to where velocity gradients are at a minimum, and thus knowledge of the precise location of a Komagata plane is not necessary. Additionally, our microfluidic device prevents electrode polarization because of fluid recirculation around the electrodes. We fabricated our device using standard MEMS fabrication techniques and performed electrophoretic mobility measurements on 500 nm fluorescently tagged polystyrene particles at various buffer concentrations. Results are comparable to two different commercial dynamic light scattering based particle sizing instruments. We conclude with guidelines to further develop this robust electrophoretic tool that allows for facile and efficient particle characterization. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Vertical bone measurements from cone beam computed tomography images using different software packages.

    PubMed

    Vasconcelos, Taruska Ventorini; Neves, Frederico Sampaio; Moraes, Lívia Almeida Bueno; Freitas, Deborah Queiroz

    2015-01-01

    This article aimed at comparing the accuracy of linear measurement tools of different commercial software packages. Eight fully edentulous dry mandibles were selected for this study. Incisor, canine, premolar, first molar and second molar regions were selected. Cone beam computed tomography (CBCT) images were obtained with i-CAT Next Generation. Linear bone measurements were performed by one observer on the cross-sectional images using three different software packages: XoranCat®, OnDemand3D® and KDIS3D®, all able to assess DICOM images. In addition, 25% of the sample was reevaluated for the purpose of reproducibility. The mandibles were sectioned to obtain the gold standard for each region. Intraclass coefficients (ICC) were calculated to examine the agreement between the two periods of evaluation; the one-way analysis of variance performed with the post-hoc Dunnett test was used to compare each of the software-derived measurements with the gold standard. The ICC values were excellent for all software packages. The least difference between the software-derived measurements and the gold standard was obtained with the OnDemand3D and KDIS3D (-0.11 and -0.14 mm, respectively), and the greatest, with the XoranCAT (+0.25 mm). However, there was no statistical significant difference between the measurements obtained with the different software packages and the gold standard (p> 0.05). In conclusion, linear bone measurements were not influenced by the software package used to reconstruct the image from CBCT DICOM data.

  10. 48 CFR 970.1100-1 - Performance-based contracting.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... methods of accomplishing the work; use measurable (i.e., terms of quality, timeliness, quantity) performance standards and objectives and quality assurance surveillance plans; provide performance incentives... work and other documents used to establish work requirements. (d) Quality assurance surveillance plans...

  11. 48 CFR 970.1100-1 - Performance-based contracting.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... methods of accomplishing the work; use measurable (i.e., terms of quality, timeliness, quantity) performance standards and objectives and quality assurance surveillance plans; provide performance incentives... work and other documents used to establish work requirements. (d) Quality assurance surveillance plans...

  12. 48 CFR 970.1100-1 - Performance-based contracting.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... methods of accomplishing the work; use measurable (i.e., terms of quality, timeliness, quantity) performance standards and objectives and quality assurance surveillance plans; provide performance incentives... work and other documents used to establish work requirements. (d) Quality assurance surveillance plans...

  13. Early childrearing practices and their relationship to academic performance in Mexican American children.

    PubMed

    Arevalo, Amanda; Kolobe, Thubi H A; Arnold, Sandra; DeGrace, Beth

    2014-01-01

    To examine whether parenting behaviors and childrearing practices in the first 3 years of life among Mexican American (MA) families predict children's academic performance at school age. Thirty-six children were assessed using the Parent Behavior Checklist, Nursing Child Assessment Teaching Scale, Home Observation for Measurement of the Environment Inventory, and Bayley Scales of Infant Development II. Academic performance was measured with the Illinois Standards Achievement Test during third grade. Correlation between parents' developmental expectations, nurturing behaviors, discipline, and academic performance were statistically significant (P < .05). Developmental expectations and discipline strategies predicted 30% of the variance in the Illinois Standards Achievement Test of reading. The results of this study suggest that early developmental expectations that MA parents have for their children, and the nurturing and discipline behaviors they engage in, are related to how well the children perform on academic tests at school age.

  14. The Real World Significance of Performance Prediction

    ERIC Educational Resources Information Center

    Pardos, Zachary A.; Wang, Qing Yang; Trivedi, Shubhendu

    2012-01-01

    In recent years, the educational data mining and user modeling communities have been aggressively introducing models for predicting student performance on external measures such as standardized tests as well as within-tutor performance. While these models have brought statistically reliable improvement to performance prediction, the real world…

  15. 76 FR 26489 - Medicare Program; Hospital Inpatient Value-Based Purchasing Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-06

    ...This final rule implements a Hospital Inpatient Value-Based Purchasing program (Hospital VBP program or the program) under section 1886(o) of the Social Security Act (the Act), under which value-based incentive payments will be made in a fiscal year to hospitals that meet performance standards with respect to a performance period for the fiscal year involved. The program will apply to payments for discharges occurring on or after October 1, 2012, in accordance with section 1886(o) (as added by section 3001(a) of the Patient Protection and Affordable Care Act, as amended by the Health Care and Education Reconciliation Act of 2010 (collectively known as the Affordable Care Act)). Scoring in the Hospital VBP program will be based on whether a hospital meets or exceeds the performance standards established with respect to the measures. By adopting this program, we will reward hospitals based on actual quality performance on measures, rather than simply reporting data for those measures.

  16. Verbal and Nonverbal Neuropsychological Test Performance in Subjects With Schizotypal Personality Disorder

    PubMed Central

    Voglmaier, Martina M.; Seidman, Larry J.; Niznikiewicz, Margaret A.; Dickey, Chandlee C.; Shenton, Martha E.; McCarley, Robert W.

    2010-01-01

    Objective The authors contrasted verbal and nonverbal measures of attention and memory in patients with DSM-IV-defined schizotypal personality disorder in order to expand on their previous findings of verbal learning deficits in these patients and to understand better the neuropsychological profile of schizotypal personality disorder. Method Cognitive test performance was examined in 16 right-handed men who met diagnostic criteria for schizotypal personality disorder and 16 matched male comparison subjects. Neuropsychological measures included verbal and nonverbal tests of persistence, supraspan learning, and short- and long-term memory retention. Neuropsychological profiles were constructed by standardizing test scores based on the means and standard deviations of the comparison subject group. Results Subjects with schizotypal personality disorder showed a mild to moderate general reduction in performance on all measures. Verbal measures of persistence, short-term retention, and learning were more severely impaired than their nonverbal analogs. Performance on measures of memory retention was independent of modality. Conclusions The results are consistent with previous reports that have suggested a mild, general decrement in cognitive performance and proportionately greater involvement of the left hemisphere in patients with schizotypal personality disorder. The findings provide further support for a specific deficit in the early processing stages of verbal learning. PMID:10784473

  17. 40 CFR 60.192 - Standard for fluorides.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standard for fluorides. 60.192 Section... Plants § 60.192 Standard for fluorides. (a) On and after the date on which the initial performance test... total fluorides, as measured according to § 60.195, in excess of: (1) 1.0 kg/Mg (2.0 lb/ton) of aluminum...

  18. 40 CFR 60.192 - Standard for fluorides.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standard for fluorides. 60.192 Section... Plants § 60.192 Standard for fluorides. (a) On and after the date on which the initial performance test... total fluorides, as measured according to § 60.195, in excess of: (1) 1.0 kg/Mg (2.0 lb/ton) of aluminum...

  19. An Exploratory Study of Reading Comprehension in College Students After Acquired Brain Injury.

    PubMed

    Sohlberg, McKay Moore; Griffiths, Gina G; Fickas, Stephen

    2015-08-01

    This exploratory study builds on the small body of existing research investigating reading comprehension deficits in college students with acquired brain injury (ABI). Twenty-four community college students with ABI completed a battery of questionnaires and standardized tests to characterize self-perceptions of academic reading ability, performance on a standardized reading comprehension measure, and a variety of cognitive functions of this population. Half of the participants in the sample reported traumatic brain injury (n = 12) and half reported nontraumatic ABI (n = 12). College students with both traumatic and nontraumatic ABI cite problems with reading comprehension and academic performance postinjury. Mean performance on a standardized reading measure, the Nelson-Denny Reading Test (Brown, Fischo, & Hanna, 1993), was low to below average and was significantly correlated with performance on the Speed and Capacity of Language Processing Test (Baddeley, Emslie, & Nimmo-Smith, 1992). Injury status of traumatic versus nontraumatic ABI did not differentiate results. Regression analysis showed that measures of verbal attention and suppression obtained from the California Verbal Language Test-II (Delis, Kramer, Kaplan, & Ober, 2000) predicted total scores on the Nelson-Denny Reading Test. College students with ABI are vulnerable to reading comprehension problems. Results align with other research suggesting that verbal attention and suppression problems may be contributing factors.

  20. Relating Standardized Visual Perception Measures to Simulator Visual System Performance

    NASA Technical Reports Server (NTRS)

    Kaiser, Mary K.; Sweet, Barbara T.

    2013-01-01

    Human vision is quantified through the use of standardized clinical vision measurements. These measurements typically include visual acuity (near and far), contrast sensitivity, color vision, stereopsis (a.k.a. stereo acuity), and visual field periphery. Simulator visual system performance is specified in terms such as brightness, contrast, color depth, color gamut, gamma, resolution, and field-of-view. How do these simulator performance characteristics relate to the perceptual experience of the pilot in the simulator? In this paper, visual acuity and contrast sensitivity will be related to simulator visual system resolution, contrast, and dynamic range; similarly, color vision will be related to color depth/color gamut. Finally, we will consider how some characteristics of human vision not typically included in current clinical assessments could be used to better inform simulator requirements (e.g., relating dynamic characteristics of human vision to update rate and other temporal display characteristics).

  1. Naval Aviation Vision Standards Research at the Naval Aerospace Medical Research Laboratory: The Long View.

    DTIC Science & Technology

    1993-04-01

    standards of personnel selection and retention that have been validated by a demonstrated relationship to succesful aviation performance. Current vision...manner in which the measurements were made. It is really quite meaningless to think of the measured correlation as indicative of some "true" correlation...of people are myopic or near-sighted in the dark. The measurement of dark focus is shown on the abscissa in Fig. 5. Negative values indicate a myopic

  2. Impact of the site specialty of a continuity practice on students' clinical skills: performance with standardized patients.

    PubMed

    Pfeiffer, Carol A; Palley, Jane E; Harrington, Karen L

    2010-07-01

    The assessment of clinical competence and the impact of training in ambulatory settings are two issues of importance in the evaluation of medical student performance. This study compares the clinical skills performance of students placed in three types of community preceptors' offices (pediatrics, medicine, family medicine) on yearly clinical skills assessments with standardized patients. Our goal was to see if the site specialty impacted on clinical performance. The students in the study were completing a 3-year continuity preceptorship at a site representing one of the disciplines. Their performance on the four clinical skills assessments was compared. There was no significant difference in history taking, physical exam, communication, or clinical reasoning in any year (ANOVA p< or = .05) There was a small but significant difference in performance on a measure of interpersonal and interviewing skills during Years 1 and 2. The site specialty of an early clinical experience does not have a significant impact on performance of most of the skills measured by the assessments.

  3. Mathematical outcomes and working memory in children with TBI and orthopedic injury.

    PubMed

    Raghubar, Kimberly P; Barnes, Marcia A; Prasad, Mary; Johnson, Chad P; Ewing-Cobbs, Linda

    2013-03-01

    This study compared mathematical outcomes in children with predominantly moderate to severe traumatic brain injury (TBI; n550) or orthopedic injury (OI; n547) at 2 and 24 months post-injury. Working memory and its contribution to math outcomes at 24 months post-injury was also examined. Participants were administered an experimental cognitive addition task and standardized measures of calculation, math fluency, and applied problems; as well as experimental measures of verbal and visual-spatial working memory. Although children with TBI did not have deficits in foundational math fact retrieval, they performed more poorly than OIs on standardized measures of math. In the TBI group, performance on standardized measures was predicted by age at injury, socioeconomic status, and the duration of impaired consciousness. Children with TBI showed impairments on verbal, but not visual working memory relative to children with OI. Verbal working memory mediated group differences on math calculations and applied problems at 24 months post-injury. Children with TBI have difficulties in mathematics, but do not have deficits in math fact retrieval, a signature deficit of math disabilities. Results are discussed with reference to models of mathematical cognition and disability and the role of working memory in math learning and performance for children with TBI.

  4. Mathematical Outcomes and Working Memory in Children With TBI and Orthopedic Injury

    PubMed Central

    Raghubar, Kimberly P.; Barnes, Marcia A.; Prasad, Mary; Johnson, Chad P.; Ewing-Cobbs, Linda

    2013-01-01

    This study compared mathematical outcomes in children with predominantly moderate to severe traumatic brain injury (TBI; n =50) or orthopedic injury (OI; n=47) at 2 and 24 months post-injury. Working memory and its contribution to math outcomes at 24 months post-injury was also examined. Participants were administered an experimental cognitive addition task and standardized measures of calculation, math fluency, and applied problems; as well as experimental measures of verbal and visual-spatial working memory. Although children with TBI did not have deficits in foundational math fact retrieval, they performed more poorly than OIs on standardized measures of math. In the TBI group, performance on standardized measures was predicted by age at injury, socioeconomic status, and the duration of impaired consciousness. Children with TBI showed impairments on verbal, but not visual working memory relative to children with OI. Verbal working memory mediated group differences on math calculations and applied problems at 24 months post-injury. Children with TBI have difficulties in mathematics, but do not have deficits in math fact retrieval, a signature deficit of math disabilities. Results are discussed with reference to models of mathematical cognition and disability and the role of working memory in math learning and performance for children with TBI. PMID:23164058

  5. Improved reliability of pH measurements.

    PubMed

    Spitzer, Petra; Werner, Barbara

    2002-11-01

    Measurements of pH are performed on a large scale at laboratory level, and in industry. To meet the quality-control requirements and other technical specifications there is a need for traceability in measurement results. The prerequisite for the international acceptance of analytical data is reliability. To measure means to compare. Comparability entails use of recognised references to which the standard buffer solutions used for calibration of pH meter-electrode assemblies can be traced. The new recommendation on the measurement of pH recently published as a provisional document by the International Union on Pure and Applied Chemistry (IUPAC) enables traceability for measured pH values to a conventional reference frame which is recognised world-wide. The primary method for pH will be described. If analytical data are to be accepted internationally it is necessary to demonstrate the equivalence of the national traceability structures, including national measurement standards. For the first time key comparisons for pH have been performed by the Consultative Committee for Amount of Substance (CCQM, set up by the International Bureau of Weights and Measures, BIPM) to assess the equivalence of the national measurement procedures used to determine the pH of primary standard buffer solutions. The results of the first key comparison on pH CCQM-K9, and other international initiatives to improve the consistency of the results of measurement for pH, are reported.

  6. Statistical Analysis of a Round-Robin Measurement Survey of Two Candidate Materials for a Seebeck Coefficient Standard Reference Material

    PubMed Central

    Lu, Z. Q. J.; Lowhorn, N. D.; Wong-Ng, W.; Zhang, W.; Thomas, E. L.; Otani, M.; Green, M. L.; Tran, T. N.; Caylor, C.; Dilley, N. R.; Downey, A.; Edwards, B.; Elsner, N.; Ghamaty, S.; Hogan, T.; Jie, Q.; Li, Q.; Martin, J.; Nolas, G.; Obara, H.; Sharp, J.; Venkatasubramanian, R.; Willigan, R.; Yang, J.; Tritt, T.

    2009-01-01

    In an effort to develop a Standard Reference Material (SRM™) for Seebeck coefficient, we have conducted a round-robin measurement survey of two candidate materials—undoped Bi2Te3 and Constantan (55 % Cu and 45 % Ni alloy). Measurements were performed in two rounds by twelve laboratories involved in active thermoelectric research using a number of different commercial and custom-built measurement systems and techniques. In this paper we report the detailed statistical analyses on the interlaboratory measurement results and the statistical methodology for analysis of irregularly sampled measurement curves in the interlaboratory study setting. Based on these results, we have selected Bi2Te3 as the prototype standard material. Once available, this SRM will be useful for future interlaboratory data comparison and instrument calibrations. PMID:27504212

  7. Do Clinical Standards for Diabetes Care Address Excess Risk for Hypoglycemia in Vulnerable Patients? A Systematic Review

    PubMed Central

    Berkowitz, Seth A; Aragon, Katherine; Hines, Jonas; Seligman, Hilary; Lee, Sei; Sarkar, Urmimala

    2013-01-01

    Objective To determine whether diabetes clinical standards consider increased hypoglycemia risk in vulnerable patients. Data Sources MEDLINE, the National Guidelines Clearinghouse, the National Quality Measures Clearinghouse, and supplemental sources. Study Design Systematic review of clinical standards (guidelines, quality metrics, or pay-for-performance programs) for glycemic control in adult diabetes patients. The primary outcome was discussion of increased risk for hypoglycemia in vulnerable populations. Data Collection/Extraction Methods Manuscripts identified were abstracted by two independent reviewers using prespecified inclusion/exclusion criteria and a standardized abstraction form. Principal Findings We screened 1,166 titles, and reviewed 220 manuscripts in full text. Forty-four guidelines, 17 quality metrics, and 8 pay-for-performance programs were included. Five (11 percent) guidelines and no quality metrics or pay-for-performance programs met the primary outcome. Conclusions Clinical standards do not substantively incorporate evidence about increased risk for hypoglycemia in vulnerable populations. PMID:23445498

  8. Do clinical standards for diabetes care address excess risk for hypoglycemia in vulnerable patients? A systematic review.

    PubMed

    Berkowitz, Seth A; Aragon, Katherine; Hines, Jonas; Seligman, Hilary; Lee, Sei; Sarkar, Urmimala

    2013-08-01

    To determine whether diabetes clinical standards consider increased hypoglycemia risk in vulnerable patients. MEDLINE, the National Guidelines Clearinghouse, the National Quality Measures Clearinghouse, and supplemental sources. Systematic review of clinical standards (guidelines, quality metrics, or pay-for-performance programs) for glycemic control in adult diabetes patients. The primary outcome was discussion of increased risk for hypoglycemia in vulnerable populations. Manuscripts identified were abstracted by two independent reviewers using prespecified inclusion/exclusion criteria and a standardized abstraction form. We screened 1,166 titles, and reviewed 220 manuscripts in full text. Forty-four guidelines, 17 quality metrics, and 8 pay-for-performance programs were included. Five (11 percent) guidelines and no quality metrics or pay-for-performance programs met the primary outcome. Clinical standards do not substantively incorporate evidence about increased risk for hypoglycemia in vulnerable populations. © Health Research and Educational Trust.

  9. Evaluation of a device for standardized measurements of reading performance in a prepresbyopic population.

    PubMed

    Arad, Tschingis; Baumeister, Martin; Bühren, Jens; Kohnen, Thomas

    2017-04-20

    Automated measurements of reading performance are required for clinical trials involving presbyopia-correcting surgery options. Repeatability of a testing device for reading (Salzburg Reading Desk) was evaluated in a prepresbyopic population. Subjective reading performance of 50 subjects divided into 2 age groups (23-30 years and 38-49 years) with distance-corrected eyes was investigated with different log-scaled reading charts. At study entry, refractive parameters were measured and distance visual acuity assessed. Two standardized binocular measurements were performed for each subject (32.24 ± 9.87 days apart [mean ± SD]). The repeatability of the tests was estimated using correlation coefficients, Wilcoxon signed-rank test, and Bland-Altman method. The test parameters at both maximum reading rate (MRR) measurements demonstrate a strong relationship of age group 2 subjects (correlation coefficient [r] = 0.74 p = 10-4) and of younger subjects (age group 1: r = 0.69, p = 10-4). Prepresbyopic subjects of age group 2 showed moderate results for near reading distance (r = 0.67, p = 10-4); by contrast, younger subjects had poorer results (r = 0.55, p = 10-3). The Wilcoxon signed-rank test revealed agreement between measurements and Bland-Altman plots showed a wide data spread for MRR and near reading distance in both groups. The device measures repeatedly selected reading performance parameters of near real world conditions, such as MRR, in prepresbyopic populations if several factors are taken into account. The option to choose preferred distance leads to more variance in measuring repeated reading performance. German Clinical Trials Register (DRKS) registration reference number: DRKS00000784.

  10. Measure Guideline: Ventilation Guidance for Residential High-Performance New Construction - Multifamily

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lstiburek, Joseph

    2017-01-01

    The measure guideline provides ventilation guidance for residential high performance multifamily construction that incorporates the requirements of the ASHRAE 62.2 ventilation and indoor air quality standard. The measure guideline focus is on the decision criteria for weighing cost and performance of various ventilation systems. The measure guideline is intended for contractors, builders, developers, designers and building code officials. The guide may also be helpful to building owners wishing to learn more about ventilation strategies available for their buildings. The measure guideline includes specific design and installation instructions for the most cost effective and performance effective solutions for ventilation in multifamilymore » units that satisfies the requirements of ASHRAE 62.2-2016.« less

  11. Measure Guideline: Ventilation Guidance for Residential High-Performance New Construction - Multifamily

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lstiburek, Joseph

    The measure guideline provides ventilation guidance for residential high performance multifamily construction that incorporates the requirements of the ASHRAE 62.2 ventilation and indoor air quality standard. The measure guideline focus is on the decision criteria for weighing cost and performance of various ventilation systems. The measure guideline is intended for contractors, builders, developers, designers and building code officials. The guide may also be helpful to building owners wishing to learn more about ventilation strategies available for their buildings. The measure guideline includes specific design and installation instructions for the most cost effective and performance effective solutions for ventilation in multifamilymore » units that satisfies the requirements of ASHRAE 62.2-2016.« less

  12. 45 CFR 305.34 - Payment of incentives.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... PROGRAM PERFORMANCE MEASURES, STANDARDS, FINANCIAL INCENTIVES, AND PENALTIES § 305.34 Payment of... performance data submitted by December 31st by the State and other States for that fiscal year. A positive or...

  13. 40 CFR 60.81 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Sulfuric Acid Plants § 60.81 Definitions... sulfur compounds. (b) Acid mist means sulfuric acid mist, as measured by Method 8 of appendix A to this...

  14. 40 CFR 60.81 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Sulfuric Acid Plants § 60.81 Definitions... sulfur compounds. (b) Acid mist means sulfuric acid mist, as measured by Method 8 of appendix A to this...

  15. 40 CFR 60.81 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Sulfuric Acid Plants § 60.81 Definitions... sulfur compounds. (b) Acid mist means sulfuric acid mist, as measured by Method 8 of appendix A to this...

  16. Testing of mechanical ventilators and infant incubators in healthcare institutions.

    PubMed

    Badnjevic, Almir; Gurbeta, Lejla; Jimenez, Elvira Ruiz; Iadanza, Ernesto

    2017-01-01

    The medical device industry has grown rapidly and incessantly over the past century. The sophistication and complexity of the designed instrumentation is nowadays rising and, with it, has also increased the need to develop some better, more effective and efficient maintenance processes, as part of the safety and performance requirements. This paper presents the results of performance tests conducted on 50 mechanical ventilators and 50 infant incubators used in various public healthcare institutions. Testing was conducted in accordance to safety and performance requirements stated in relevant international standards, directives and legal metrology policies. Testing of output parameters for mechanical ventilators was performed in 4 measuring points while testing of output parameters for infant incubators was performed in 7 measuring points for each infant incubator. As performance criteria, relative error of output parameters for mechanical ventilators and absolute error of output parameters for infant incubators was calculated. The ranges of permissible error, for both groups of devices, are regulated by the Rules on Metrological and Technical Requirements published in the Official Gazette of Bosnia and Herzegovina No. 75/14, which are defined based on international recommendations, standards and guidelines. All ventilators and incubators were tested by etalons calibrated in an ISO 17025 accredited laboratory, which provides compliance to international standards for all measured parameters.The results show that 30% of the tested medical devices are not operating properly and should be serviced, recalibrated and/or removed from daily application.

  17. 42 CFR 401.715 - Selection and use of performance measures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... switch to the standard measure within 6 months or submit additional scientific justification and receive... the discussion about the proposed alternative measure, including a summary of all pertinent arguments... another qualified entity, no new scientific evidence on the measure is available, and the subsequent...

  18. 42 CFR 401.715 - Selection and use of performance measures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... switch to the standard measure within 6 months or submit additional scientific justification and receive... the discussion about the proposed alternative measure, including a summary of all pertinent arguments... another qualified entity, no new scientific evidence on the measure is available, and the subsequent...

  19. 42 CFR 401.715 - Selection and use of performance measures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... switch to the standard measure within 6 months or submit additional scientific justification and receive... the discussion about the proposed alternative measure, including a summary of all pertinent arguments... another qualified entity, no new scientific evidence on the measure is available, and the subsequent...

  20. Systematic behavioural observation of executive performance after brain injury.

    PubMed

    Lewis, Mark W; Babbage, Duncan R; Leathem, Janet M

    2017-01-01

    To develop an ecologically valid measure of executive functioning (i.e. Planning and Organization, Executive Memory, Initiation, Cognitive Shifting, Impulsivity, Sustained and Directed Attention, Error Detection, Error Correction and Time Management) during a functional chocolate brownie cooking task. In Study 1, the inter-rater reliability of a novel behavioural observation assessment method was assessed with 10 people with traumatic brain injury (TBI). In Study 2, 27 people with TBI and 16 healthy controls completed the functional task along with other measures of executive functioning to assess validity. Intraclass correlation coefficients for six of the nine aspects of executive functioning ranged from .54 to 1.00. Percentage agreements for the remaining aspects ranged from 70% to 90%. Significant and non-significant, moderate, correlations were found between the functional cooking task and standard neuropsychological measures. The healthy control group performed better than the TBI group in six areas (d = 0.56 to 1.23). In this initial trial of a novel assessment method, adequate inter-rater reliability was found. The measure was associated with standard neuropsychological measures, and our healthy control group performed better than the TBI group. The measure appears to be an ecologically valid measure of executive functioning.

  1. Neuropsychologic predictors of competency in Alzheimer's disease using a rational reasons legal standard.

    PubMed

    Marson, D C; Cody, H A; Ingram, K K; Harrell, L E

    1995-10-01

    To identify neuropsychologic predictors of competency performance and status in Alzheimer's disease (AD) using a specific legal standard (LS). This study is a follow-up to the competency assessment research reported in this issue of the archives. Univariate and multivariate analyses of independent neuropsychologic test measures with a dependent measure of competency to consent to treatment. University medical center. Fifteen normal older control subjects and 29 patients with probable AD. Subjects were administered a battery of neuropsychologic measures theoretically linked to competency function, as well as two clinical vignettes testing their capacity to consent to medical treatment under five different LSs. The present study focused on one specific LS: the capacity to provide "rational reasons" for a treatment choice (LS4). Neuropsychologic test scores were correlated with scores on LS4 for the normal control group and the AD group. The resulting univariate predictors were then analyzed using stepwise regression and discriminant function to identify the key multivariate predictors of competency performance and status under LS4. Measures of word fluency predicted the LS4 scores of controls (R2 = .33) and the AD group (R2 = .36). A word fluency measure also emerged as the best single predictor of competency status for the full subject sample (n = 44), correctly classifying 82% of cases. Dementia severity (Mini-Mental State Examination score) did not emerge as a multivariate predictor of competency performance or status. Interestingly, measures of verbal reasoning and memory were not strongly associated with LS4. Word fluency measures predicted the normative performance and intact competency status of older control subjects and the declining performance and compromised competency status of patients with AD on a "rational reasons" standard of competency to consent to treatment. Cognitive capacities related to frontal lobe function appear to underlie the capacity to formulate rational reasons for a treatment choice. Neuropsychologic studies of competency function have important theoretical and clinical value.

  2. Functional assessment and performance evaluation for assistive robotic manipulators: Literature review.

    PubMed

    Chung, Cheng-Shiu; Wang, Hongwu; Cooper, Rory A

    2013-07-01

    The user interface development of assistive robotic manipulators can be traced back to the 1960s. Studies include kinematic designs, cost-efficiency, user experience involvements, and performance evaluation. This paper is to review studies conducted with clinical trials using activities of daily living (ADLs) tasks to evaluate performance categorized using the International Classification of Functioning, Disability, and Health (ICF) frameworks, in order to give the scope of current research and provide suggestions for future studies. We conducted a literature search of assistive robotic manipulators from 1970 to 2012 in PubMed, Google Scholar, and University of Pittsburgh Library System - PITTCat. Twenty relevant studies were identified. Studies were separated into two broad categories: user task preferences and user-interface performance measurements of commercialized and developing assistive robotic manipulators. The outcome measures and ICF codes associated with the performance evaluations are reported. Suggestions for the future studies include (1) standardized ADL tasks for the quantitative and qualitative evaluation of task efficiency and performance to build comparable measures between research groups, (2) studies relevant to the tasks from user priority lists and ICF codes, and (3) appropriate clinical functional assessment tests with consideration of constraints in assistive robotic manipulator user interfaces. In addition, these outcome measures will help physicians and therapists build standardized tools while prescribing and assessing assistive robotic manipulators.

  3. Spatial enhancement of ECG using diagnostic similarity score based lead selective multi-scale linear model.

    PubMed

    Nallikuzhy, Jiss J; Dandapat, S

    2017-06-01

    In this work, a new patient-specific approach to enhance the spatial resolution of ECG is proposed and evaluated. The proposed model transforms a three-lead ECG into a standard twelve-lead ECG thereby enhancing its spatial resolution. The three leads used for prediction are obtained from the standard twelve-lead ECG. The proposed model takes advantage of the improved inter-lead correlation in wavelet domain. Since the model is patient-specific, it also selects the optimal predictor leads for a given patient using a lead selection algorithm. The lead selection algorithm is based on a new diagnostic similarity score which computes the diagnostic closeness between the original and the spatially enhanced leads. Standard closeness measures are used to assess the performance of the model. The similarity in diagnostic information between the original and the spatially enhanced leads are evaluated using various diagnostic measures. Repeatability and diagnosability are performed to quantify the applicability of the model. A comparison of the proposed model is performed with existing models that transform a subset of standard twelve-lead ECG into the standard twelve-lead ECG. From the analysis of the results, it is evident that the proposed model preserves diagnostic information better compared to other models. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. 45 CFR 305.33 - Determination of applicable percentages based on performance levels.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., DEPARTMENT OF HEALTH AND HUMAN SERVICES PROGRAM PERFORMANCE MEASURES, STANDARDS, FINANCIAL INCENTIVES, AND PENALTIES § 305.33 Determination of applicable percentages based on performance levels. (a) A State's... performance levels. 305.33 Section 305.33 Public Welfare Regulations Relating to Public Welfare OFFICE OF...

  5. The Michigan Context and Performance Report Card: Public Elementary & Middle Schools, 2013

    ERIC Educational Resources Information Center

    Spalding, Audrey

    2013-01-01

    The Michigan Context and Performance Report Card measures school performance by adjusting standardized test scores to account for student background. Comparing schools using unadjusted test scores ignores the significant relationship between academic performance and student socioeconomic background--a dynamic outside a school's control. The…

  6. Evaluating Library Staff: A Performance Appraisal System.

    ERIC Educational Resources Information Center

    Belcastro, Patricia

    This manual provides librarians and library managers with a performance appraisal system that measures staff fairly and objectively and links performance to the goals of the library. The following topics are addressed: (1) identifying expectations for quality service or standards of performance; (2) the importance of a library's code of service,…

  7. 42 CFR 438.240 - Quality assessment and performance improvement program.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Quality assessment and performance improvement... Performance Improvement Measurement and Improvement Standards § 438.240 Quality assessment and performance improvement program. (a) General rules. (1) The State must require, through its contracts, that each MCO and...

  8. Consistency of the National Realization of Dew-Point Temperature Using Standard Humidity Generators

    NASA Astrophysics Data System (ADS)

    Benyon, R.; Vicente, T.

    2012-09-01

    The comparison of two high-range standard humidity generators used by Instituto Nacional de Técnica Aeroespacial to realize dew-point temperature in the range from -10 °C to +95 °C has been performed using state-of-the art transfer standards and measurement procedures, over their overlapping range from -10 °C to +75 °C. The aim of this study is to investigate the level of agreement between the two generators, to determine any bias, and to quantify the level of consistency of the two realizations. The measurement procedures adopted to minimize the effect of the influence factors due to the transfer standards are described, and the results are discussed in the context of the declared calibration and measurement capabilities (CMCs).

  9. Random errors in interferometry with the least-squares method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang Qi

    2011-01-20

    This investigation analyzes random errors in interferometric surface profilers using the least-squares method when random noises are present. Two types of random noise are considered here: intensity noise and position noise. Two formulas have been derived for estimating the standard deviations of the surface height measurements: one is for estimating the standard deviation when only intensity noise is present, and the other is for estimating the standard deviation when only position noise is present. Measurements on simulated noisy interferometric data have been performed, and standard deviations of the simulated measurements have been compared with those theoretically derived. The relationships havemore » also been discussed between random error and the wavelength of the light source and between random error and the amplitude of the interference fringe.« less

  10. An automated LS(β)- NaI(Tl)(γ) coincidence system as absolute standard for radioactivity measurements.

    PubMed

    Joseph, Leena; Das, A P; Ravindra, Anuradha; Kulkarni, D B; Kulkarni, M S

    2018-07-01

    4πβ-γ coincidence method is a powerful and widely used method to determine the absolute activity concentration of radioactive solutions. A new automated liquid scintillator based coincidence system has been designed, developed, tested and established as absolute standard for radioactivity measurements. The automation is achieved using PLC (programmable logic controller) and SCADA (supervisory control and data acquisition). Radioactive solution of 60 Co was standardized to compare the performance of the automated system with proportional counter based absolute standard maintained in the laboratory. The activity concentrations determined using these two systems were in very good agreement; the new automated system can be used for absolute measurement of activity concentration of radioactive solutions. Copyright © 2018. Published by Elsevier Ltd.

  11. Microwave cryogenic thermal-noise standards

    NASA Technical Reports Server (NTRS)

    Stelzried, C. T.

    1971-01-01

    Field operational waveguide noise standard with nominal noise temperature of 78.09 plus/minus 0.12 deg K is calibrated more precisely than before. Calibration technique applies to various disciplines such as microwave radiometry, antenna temperature and loss measurement, and low-noise amplifier performance evaluation.

  12. Laboratory Performance Evaluation Report of SEL 421 Phasor Measurement Unit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Zhenyu; faris, Anthony J.; Martin, Kenneth E.

    2007-12-01

    PNNL and BPA have been in close collaboration on laboratory performance evaluation of phasor measurement units for over ten years. A series of evaluation tests are designed to confirm accuracy and determine measurement performance under a variety of conditions that may be encountered in actual use. Ultimately the testing conducted should provide parameters that can be used to adjust all measurements to a standardized basis. These tests are performed with a standard relay test set using recorded files of precisely generated test signals. The test set provides test signals at a level and in a format suitable for input tomore » a PMU that accurately reproduces the signals in both signal amplitude and timing. Test set outputs are checked to confirm the accuracy of the output signal. The recorded signals include both current and voltage waveforms and a digital timing track used to relate the PMU measured value with the test signal. Test signals include steady-state waveforms to test amplitude, phase, and frequency accuracy, modulated signals to determine measurement and rejection bands, and step tests to determine timing and response accuracy. Additional tests are included as necessary to fully describe the PMU operation. Testing is done with a BPA phasor data concentrator (PDC) which provides communication support and monitors data input for dropouts and data errors.« less

  13. Setting Foundations for Developing Disaster Response Metrics.

    PubMed

    Abir, Mahshid; Bell, Sue Anne; Puppala, Neha; Awad, Osama; Moore, Melinda

    2017-08-01

    There are few reported efforts to define universal disaster response performance measures. Careful examination of responses to past disasters can inform the development of such measures. As a first step toward this goal, we conducted a literature review to identify key factors in responses to 3 recent events with significant loss of human life and economic impact: the 2003 Bam, Iran, earthquake; the 2004 Indian Ocean tsunami; and the 2010 Haiti earthquake. Using the PubMed (National Library of Medicine, Bethesda, MD) database, we identified 710 articles and retained 124 after applying inclusion and exclusion criteria. Seventy-two articles pertained to the Haiti earthquake, 38 to the Indian Ocean tsunami, and 14 to the Bam earthquake. On the basis of this review, we developed an organizational framework for disaster response performance measurement with 5 key disaster response categories: (1) personnel, (2) supplies and equipment, (3) transportation, (4) timeliness and efficiency, and (5) interagency cooperation. Under each of these, and again informed by the literature, we identified subcategories and specific items that could be developed into standardized performance measures. The validity and comprehensiveness of these measures can be tested by applying them to other recent and future disaster responses, after which standardized performance measures can be developed through a consensus process. (Disaster Med Public Health Preparedness. 2017;11:505-509).

  14. CCQM-K90, formaldehyde in nitrogen, 2 μmol mol-1 Final report

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Flores, Edgar; Idrees, Faraz; Moussay, Philippe; Wielgosz, Robert Ian; Kim, D.; Kim, Y. D.; Lee, S.; Persijn, S.; Konopelko, L. A.; Kustikov, Y. A.; Malginov, A. V.; Chubchenko, I. K.; Klimov, A. Y.; Efremova, O. V.; Zhou, Z.; Possolo, A.; Shimosaka, T.; Brewer, P.; Macé, T.; Ferracci, Valerio; Brown, Richard J. C.; Aoki, Nobuyuki

    2017-01-01

    The CCQM-K90 comparison is designed to evaluate the level of comparability of national metrology institutes (NMI) or designated institutes (DI) measurement capabilities for formaldehyde in nitrogen at a nominal mole fraction of 2 μmol mol-1. The comparison was organised by the BIPM using a suite of gas mixtures prepared by a producer of specialty calibration gases. The BIPM assigned the formaldehyde mole fraction in the mixtures by comparison with primary mixtures generated dynamically by permeation coupled with continuous weighing in a magnetic suspension balance. The BIPM developed two dynamic sources of formaldehyde in nitrogen that provide two independent values of the formaldehyde mole fraction: the first one based on diffusion of trioxane followed by thermal conversion to formaldehyde, the second one based on permeation of formaldehyde from paraformaldehyde contained in a permeation tube. Two independent analytical methods, based on cavity ring down spectroscopy (CRDS) and Fourier transform infrared spectroscopy (FTIR) were used for the assignment procedure. Each participating institute was provided with one transfer standard and value assigned the formaldehyde mole fraction in the standard based on its own measurement capabilities. The stability of the formaldehyde mole fraction in transfer standards was deduced from repeated measurements performed at the BIPM before and after measurements performed at participating institutes. In addition, 5 control standards were kept at the BIPM for regular measurements during the course of the comparison. Temporal trends that approximately describe the linear decrease of the amount-of-substance fraction of formaldehyde in nitrogen in the transfer standards over time were estimated by two different mathematical treatments, the outcomes of which were proposed to participants. The two treatments also differed in the way measurement uncertainties arising from measurements performed at the BIPM were propagated to the uncertainty of the trend parameters, as well as how the dispersion of the dates when measurements were made by the participants was taken into account. Upon decision of the participants, the Key Comparison Reference Values were assigned by the BIPM using the largest uncertainty for measurements performed at the BIPM, linear regression without weight to calculate the trend parameters, and not taking into account the dispersion of dates for measurements made by the participant. Each transfer standard was assigned its own reference value and associated expanded uncertainty. An expression for the degree of equivalence between each participating institute and the KCRV was calculated from the comparison results and measurement uncertainties submitted by participating laboratories. Results of the alternative mathematical treatment are presented in annex of this report. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Factor structure of a standards-based inventory of competencies in social work with groups.

    PubMed

    Macgowan, Mark J; Dillon, Frank R; Spadola, Christine E

    2018-01-01

    This study extends previous findings on a measure of competencies based on Standards for Social Work Practice with Groups. The Inventory of Competencies in Social Work with Groups (ICSWG) measures confidence in performing the Standards. This study examines the latent structure of the Inventory, while illuminating the underlying structure of the Standards. A multinational sample of 586 persons completed the ICSWG. Exploratory factor analysis (EFA), reliability estimates, standard error of measurement estimates, and a range of validity tests were conducted. The EFA yielded a six-factor solution consisting of core values, mutuality/connectivity, collaboration, and three phases of group development (planning, beginnings/middles, endings). The alphas were .98 for the scale and ranged from .85 to .95 for the subscales. Correlations between the subscales and validators supported evidence of construct validity. The findings suggest key group work domains that should be taught and practiced in social work with groups.

  16. An Interlaboratory Evaluation of Drift Tube Ion Mobility–Mass Spectrometry Collision Cross Section Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stow, Sarah M.; Causon, Tim J.; Zheng, Xueyun

    Collision cross section (CCS) measurements resulting from ion mobility-mass spectrometry (IM-MS) experiments provide a promising orthogonal dimension of structural information in MS-based analytical separations. As with any molecular identifier, interlaboratory standardization must precede broad range integration into analytical workflows. In this study, we present a reference drift tube ion mobility mass spectrometer (DTIM-MS) where improvements on the measurement accuracy of experimental parameters influencing IM separations provide standardized drift tube, nitrogen CCS values (DTCCSN2) for over 120 unique ion species with the lowest measurement uncertainty to date. The reproducibility of these DTCCSN2 values are evaluated across three additional laboratories on amore » commercially available DTIM-MS instrument. The traditional stepped field CCS method performs with a relative standard deviation (RSD) of 0.29% for all ion species across the three additional laboratories. The calibrated single field CCS method, which is compatible with a wide range of chromatographic inlet systems, performs with an average, absolute bias of 0.54% to the standardized stepped field DTCCSN2 values on the reference system. The low RSD and biases observed in this interlaboratory study illustrate the potential of DTIM-MS for providing a molecular identifier for a broad range of discovery based analyses.« less

  17. Cerebral Small Vessel Disease Burden Is Associated with Motor Performance of Lower and Upper Extremities in Community-Dwelling Populations

    PubMed Central

    Su, Ning; Zhai, Fei-Fei; Zhou, Li-Xin; Ni, Jun; Yao, Ming; Li, Ming-Li; Jin, Zheng-Yu; Gong, Gao-Lang; Zhang, Shu-Yang; Cui, Li-Ying; Tian, Feng; Zhu, Yi-Cheng

    2017-01-01

    Objective: To investigate the correlation between cerebral small vessel disease (CSVD) burden and motor performance of lower and upper extremities in community-dwelling populations. Methods: We performed a cross-sectional analysis on 770 participants enrolled in the Shunyi study, which is a population-based cohort study. CSVD burden, including white matter hyperintensities (WMH), lacunes, cerebral microbleeds (CMBs), perivascular spaces (PVS), and brain atrophy were measured using 3T magnetic resonance imaging. All participants underwent quantitative motor assessment of lower and upper extremities, which included 3-m walking speed, 5-repeat chair-stand time, 10-repeat pronation–supination time, and 10-repeat finger-tapping time. Data on demographic characteristics, vascular risk factors, and cognitive functions were collected. General linear model analysis was performed to identify potential correlations between motor performance measures and imaging markers of CSVD after controlling for confounding factors. Results: For motor performance of the lower extremities, WMH was negatively associated with gait speed (standardized β = -0.092, p = 0.022) and positively associated with chair-stand time (standardized β = 0.153, p < 0.0001, surviving FDR correction). For motor performance of the upper extremities, pronation–supination time was positively associated with WMH (standardized β = 0.155, p < 0.0001, surviving FDR correction) and negatively with brain parenchymal fraction (BPF; standardized β = -0.125, p = 0.011, surviving FDR correction). Only BPF was found to be negatively associated with finger-tapping time (standardized β = -0.123, p = 0.012). However, lacunes, CMBs, or PVS were not found to be associated with motor performance of lower or upper extremities in multivariable analysis. Conclusion: Our findings suggest that cerebral microstructural changes related to CSVD may affect motor performance of both lower and upper extremities. WMH and brain atrophy are most strongly associated with motor function deterioration in community-dwelling populations. PMID:29021757

  18. Cerebral Small Vessel Disease Burden Is Associated with Motor Performance of Lower and Upper Extremities in Community-Dwelling Populations.

    PubMed

    Su, Ning; Zhai, Fei-Fei; Zhou, Li-Xin; Ni, Jun; Yao, Ming; Li, Ming-Li; Jin, Zheng-Yu; Gong, Gao-Lang; Zhang, Shu-Yang; Cui, Li-Ying; Tian, Feng; Zhu, Yi-Cheng

    2017-01-01

    Objective: To investigate the correlation between cerebral small vessel disease (CSVD) burden and motor performance of lower and upper extremities in community-dwelling populations. Methods: We performed a cross-sectional analysis on 770 participants enrolled in the Shunyi study, which is a population-based cohort study. CSVD burden, including white matter hyperintensities (WMH), lacunes, cerebral microbleeds (CMBs), perivascular spaces (PVS), and brain atrophy were measured using 3T magnetic resonance imaging. All participants underwent quantitative motor assessment of lower and upper extremities, which included 3-m walking speed, 5-repeat chair-stand time, 10-repeat pronation-supination time, and 10-repeat finger-tapping time. Data on demographic characteristics, vascular risk factors, and cognitive functions were collected. General linear model analysis was performed to identify potential correlations between motor performance measures and imaging markers of CSVD after controlling for confounding factors. Results: For motor performance of the lower extremities, WMH was negatively associated with gait speed (standardized β = -0.092, p = 0.022) and positively associated with chair-stand time (standardized β = 0.153, p < 0.0001, surviving FDR correction). For motor performance of the upper extremities, pronation-supination time was positively associated with WMH (standardized β = 0.155, p < 0.0001, surviving FDR correction) and negatively with brain parenchymal fraction (BPF; standardized β = -0.125, p = 0.011, surviving FDR correction). Only BPF was found to be negatively associated with finger-tapping time (standardized β = -0.123, p = 0.012). However, lacunes, CMBs, or PVS were not found to be associated with motor performance of lower or upper extremities in multivariable analysis. Conclusion: Our findings suggest that cerebral microstructural changes related to CSVD may affect motor performance of both lower and upper extremities. WMH and brain atrophy are most strongly associated with motor function deterioration in community-dwelling populations.

  19. Emergency medical services key performance measurement in Asian cities.

    PubMed

    Rahman, Nik Hisamuddin; Tanaka, Hideharu; Shin, Sang Do; Ng, Yih Yng; Piyasuwankul, Thammapad; Lin, Chih-Hao; Ong, Marcus Eng Hock

    2015-01-01

    One of the key principles in the recommended standards is that emergency medical service (EMS) providers should continuously monitor the quality and safety of their services. This requires service providers to implement performance monitoring using appropriate and relevant measures including key performance indicators. In Asia, EMS systems are at different developmental phases and maturity. This will create difficultly in benchmarking or assessing the quality of EMS performance across the region. An attempt was made to compare the EMS performance index based on the structure, process, and outcome analysis. The data was collected from the Pan-Asian Resuscitation Outcome Study (PAROS) data among few Asian cities, namely, Tokyo, Osaka, Singapore, Bangkok, Kuala Lumpur, Taipei, and Seoul. The parameters of inclusions were broadly divided into structure, process, and outcome measurements. The data was collected by the site investigators from each city and keyed into the electronic web-based data form which is secured strictly by username and passwords. Generally, there seems to be a more uniformity for EMS performance parameters among the more developed EMS systems. The major problem with the EMS agencies in the cities of developing countries like Bangkok and Kuala Lumpur is inadequate or unavailable data pertaining to EMS performance. There is non-uniformity in the EMS performance measurement across the Asian cities. This creates difficulty for EMS performance index comparison and benchmarking. Hopefully, in the future, collaborative efforts such as the PAROS networking group will further enhance the standardization in EMS performance reporting across the region.

  20. ASME B89.4.19 Performance Evaluation Tests and Geometric Misalignments in Laser Trackers

    PubMed Central

    Muralikrishnan, B.; Sawyer, D.; Blackburn, C.; Phillips, S.; Borchardt, B.; Estler, W. T.

    2009-01-01

    Small and unintended offsets, tilts, and eccentricity of the mechanical and optical components in laser trackers introduce systematic errors in the measured spherical coordinates (angles and range readings) and possibly in the calculated lengths of reference artifacts. It is desirable that the tests described in the ASME B89.4.19 Standard [1] be sensitive to these geometric misalignments so that any resulting systematic errors are identified during performance evaluation. In this paper, we present some analysis, using error models and numerical simulation, of the sensitivity of the length measurement system tests and two-face system tests in the B89.4.19 Standard to misalignments in laser trackers. We highlight key attributes of the testing strategy adopted in the Standard and propose new length measurement system tests that demonstrate improved sensitivity to some misalignments. Experimental results with a tracker that is not properly error corrected for the effects of the misalignments validate claims regarding the proposed new length tests. PMID:27504211

  1. Comparison of methodologies for calculating quality measures based on administrative data versus clinical data from an electronic health record system: implications for performance measures.

    PubMed

    Tang, Paul C; Ralston, Mary; Arrigotti, Michelle Fernandez; Qureshi, Lubna; Graham, Justin

    2007-01-01

    New reimbursement policies and pay-for-performance programs to reward providers for producing better outcomes are proliferating. Although electronic health record (EHR) systems could provide essential clinical data upon which to base quality measures, most metrics in use were derived from administrative claims data. We compared commonly used quality measures calculated from administrative data to those derived from clinical data in an EHR based on a random sample of 125 charts of Medicare patients with diabetes. Using standard definitions based on administrative data (which require two visits with an encounter diagnosis of diabetes during the measurement period), only 75% of diabetics determined by manually reviewing the EHR (the gold standard) were identified. In contrast, 97% of diabetics were identified using coded information in the EHR. The discrepancies in identified patients resulted in statistically significant differences in the quality measures for frequency of HbA1c testing, control of blood pressure, frequency of testing for urine protein, and frequency of eye exams for diabetic patients. New development of standardized quality measures should shift from claims-based measures to clinically based measures that can be derived from coded information in an EHR. Using data from EHRs will also leverage their clinical content without adding burden to the care process.

  2. A novel cuffless device for self-measurement of blood pressure: concept, performance and clinical validation.

    PubMed

    Boubouchairopoulou, N; Kollias, A; Chiu, B; Chen, B; Lagou, S; Anestis, P; Stergiou, G S

    2017-07-01

    A pocket-size cuffless electronic device for self-measurement of blood pressure (BP) has been developed (Freescan, Maisense Inc., Zhubei, Taiwan). The device estimates BP within 10 s using three embedded electrodes and one force sensor that is applied over the radial pulse to evaluate the pulse wave. Before use, basic anthropometric characteristics are recorded on the device, and individualized initial calibration is required based on a standard BP measurement performed using an upper-arm BP monitor. The device performance in providing valid BP readings was evaluated in 313 normotensive and hypertensive adults in three study phases during which the device sensor was upgraded. A formal validation study of a prototype device against mercury sphygmomanometer was performed according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization (ANSI/AAMI/ISO) 2013 protocol. The test device succeeded in obtaining a valid BP measurement (three successful readings within up to five attempts) in 55-72% of the participants, which reached 87% with device sensor upgrade. For the validation study, 125 adults were recruited and 85 met the protocol requirements for inclusion. The mean device-observers BP difference was 3.2±6.7 (s.d.) mm Hg for systolic and 2.6±4.6 mm Hg for diastolic BP (criterion 1). The estimated s.d. (inter-subject variability) were 5.83 and 4.17 mm Hg respectively (criterion 2). These data suggest that this prototype cuffless BP monitor provides valid self-measurements in the vast majority of adults, and satisfies the BP measurement accuracy criteria of the ANSI/AAMI/ISO 2013 validation protocol.

  3. Achieving high quality colonoscopy: using graphical representation to measure performance and reset standards.

    PubMed

    Rajasekhar, P T; Rutter, M D; Bramble, M G; Wilson, D W; East, J E; Greenaway, J R; Saunders, B P; Lee, T J W; Barton, R; Hungin, A P S; Rees, C J

    2012-12-01

    Completeness and thoroughness of colonoscopy are measured by the caecal intubation rate (CIR) and the adenoma detection rate (ADR). National standards are ≥ 90% and ≥ 10% respectively. Variability in CIR and ADR have been demonstrated but comparison between individuals and units is difficult. We aimed to assess the performance of colonoscopy in endoscopy units in the northeast of England. Data on colonoscopy performance and sedation use were collected over 3 months from 12 units. Colonoscopies performed by screening colonoscopists were included for the CIR only. Funnel plots with upper and lower 95% confidence limits for CIR and ADR were created. CIR was 92.5% (n = 5720) and ADR 15.9% (n = 4748). All units and 128 (99.2%) colonoscopists were above the lower limit for CIR. All units achieved the ADR standard with 10 above the upper limit. Ninety-nine (76.7%) colonoscopists were above 10%, 16 (12.4%) above the upper limit and 7 (5.4%) below the lower limit. Median medication doses were 2.2 mg midazolam, 29.4 mg pethidine and 83.3 μg fentanyl. In all, 15.1% of colonoscopies were unsedated. Complications were bleeding (0.10%) and perforation (0.02%). There was one death possibly related to bowel preparation. Results indicate that colonoscopies are performed safely and to a high standard. Funnel plots can highlight variability and areas for improvement. Analyses of ADR presented graphically around the global mean suggest that the national standard should be reset at 15%. © 2012 The Authors. Colorectal Disease © 2012 The Association of Coloproctology of Great Britain and Ireland.

  4. Development of a standardized battery of performance tests for the assessment of noise stress effects

    NASA Technical Reports Server (NTRS)

    Theologus, G. C.; Wheaton, G. R.; Mirabella, A.; Brahlek, R. E.

    1973-01-01

    A set of 36 relatively independent categories of human performance were identified. These categories encompass human performance in the cognitive, perceptual, and psychomotor areas, and include diagnostic measures and sensitive performance metrics. Then a prototype standardized test battery was constructed, and research was conducted to obtain information on the sensitivity of the tests to stress, the sensitivity of selected categories of performance degradation, the time course of stress effects on each of the selected tests, and the learning curves associated with each test. A research project utilizing a three factor partially repeated analysis of covariance design was conducted in which 60 male subjects were exposed to variations in noise level and quality during performance testing. Effects of randomly intermittent noise on performance of the reaction time tests were observed, but most of the other performance tests showed consistent stability. The results of 14 analyses of covariance of the data taken from the performance of the 60 subjects on the prototype standardized test battery provided information which will enable the final development and test of a standardized test battery and the associated development of differential sensitivity metrics and diagnostic classificatory system.

  5. Accuracy of force and center of pressure measures of the Wii Balance Board.

    PubMed

    Bartlett, Harrison L; Ting, Lena H; Bingham, Jeffrey T

    2014-01-01

    The Nintendo Wii Balance Board (WBB) is increasingly used as an inexpensive force plate for assessment of postural control; however, no documentation of force and COP accuracy and reliability is publicly available. Therefore, we performed a standard measurement uncertainty analysis on 3 lightly and 6 heavily used WBBs to provide future users with information about the repeatability and accuracy of the WBB force and COP measurements. Across WBBs, we found the total uncertainty of force measurements to be within ± 9.1N, and of COP location within ± 4.1mm. However, repeatability of a single measurement within a board was better (4.5 N, 1.5mm), suggesting that the WBB is best used for relative measures using the same device, rather than absolute measurement across devices. Internally stored calibration values were comparable to those determined experimentally. Further, heavy wear did not significantly degrade performance. In combination with prior evaluation of WBB performance and published standards for measuring human balance, our study provides necessary information to evaluate the use of the WBB for analysis of human balance control. We suggest the WBB may be useful for low-resolution measurements, but should not be considered as a replacement for laboratory-grade force plates. Published by Elsevier B.V.

  6. Accuracy of force and center of pressure measures of the Wii Balance Board

    PubMed Central

    Bartlett, Harrison L.; Ting, Lena H.; Bingham, Jeffrey T.

    2013-01-01

    The Nintendo Wii Balance Board (WBB) is increasingly used as an inexpensive force plate for assessment of postural control; however, no documentation of force and COP accuracy and reliability is publicly available. Therefore, we performed a standard measurement uncertainty analysis on 3 lightly and 6 heavily used WBBs to provide future users with information about the repeatability and accuracy of the WBB force and COP measurements. Across WBBs, we found the total uncertainty of force measurements to be within ±9.1 N, and of COP location within ±4.1 mm. However, repeatability of a single measurement within a board was better (4.5 N, 1.5 mm), suggesting that the WBB is best used for relative measures using the same device, rather than absolute measurement across devices. Internally stored calibration values were comparable to those determined experimentally. Further, heavy wear did not significantly degrade performance. In combination with prior evaluation of WBB performance and published standards for measuring human balance, our study provides necessary information to evaluate the use of the WBB for analysis of human balance control. We suggest the WBB may be useful for low-resolution measurements, but should not be considered as a replacement for laboratory-grade force plates. PMID:23910725

  7. PV System 'Availability' as a Reliability Metric -- Improving Standards, Contract Language and Performance Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klise, Geoffrey T.; Hill, Roger; Walker, Andy

    The use of the term 'availability' to describe a photovoltaic (PV) system and power plant has been fraught with confusion for many years. A term that is meant to describe equipment operational status is often omitted, misapplied or inaccurately combined with PV performance metrics due to attempts to measure performance and reliability through the lens of traditional power plant language. This paper discusses three areas where current research in standards, contract language and performance modeling is improving the way availability is used with regards to photovoltaic systems and power plants.

  8. PROSPECTIVE EVALUATION OF VISUAL ACUITY AGREEMENT BETWEEN STANDARD EARLY TREATMENT DIABETIC RETINOPATHY STUDY CHART AND A HANDHELD EQUIVALENT IN EYES WITH RETINAL PATHOLOGY.

    PubMed

    Rahimy, Ehsan; Reddy, Sahitya; DeCroos, Francis Char; Khan, M Ali; Boyer, David S; Gupta, Omesh P; Regillo, Carl D; Haller, Julia A

    2015-08-01

    To evaluate the visual acuity agreement between a standard back-illuminated Early Treatment Diabetic Retinopathy Study (ETDRS) chart and a handheld internally illuminated ETDRS chart. Two-center prospective study. Seventy patients (134 eyes) with retinal pathology were enrolled between October 2012 and August 2013. Visual acuity was measured using both the ETDRS chart and the handheld device by masked independent examiners after best protocol refraction. Examination was performed in the same room under identical illumination and testing conditions. The mean number of letters seen was 63.0 (standard deviation: 19.8 letters) and 61.2 letters (standard deviation: 19.1 letters) for the ETDRS chart and handheld device, respectively. Mean difference per eye between the ETDRS and handheld device was 1.8 letters. A correlation coefficient (r) of 0.95 demonstrated a positive linear correlation between ETDRS chart and handheld device measured acuities. Intraclass correlation coefficient was performed to assess the reproducibility of the measurements made by different observers measuring the same quantity and was calculated to be 0.95 (95% confidence interval: 0.93-0.96). Agreement was independent of retinal disease. The strong correlation between measured visual acuity using the ETDRS and handheld equivalent suggests that they may be used interchangeably, with accurate measurements. Potential benefits of this device include convenience and portability, as well as the ability to assess ETDRS visual acuity without a dedicated testing lane.

  9. MOSFET detectors in quality assurance of tomotherapy treatments.

    PubMed

    Cherpak, Amanda; Studinski, Ryan C N; Cygler, Joanna E

    2008-02-01

    The purpose of this work was to characterize metal oxide semiconductor field-effect transistors (MOSFETs) in a 6 MV conventional linac and investigate their use for quality assurance of radiotherapy treatments with a tomotherapy Hi-Art unit. High sensitivity and standard sensitivity MOSFETs were first calibrated and then tested for reproducibility, field size dependence, and accuracy of measuring surface dose in a 6 MV beam as well as in a tomotherapy Hi-Art unit. In vivo measurements were performed on both a RANDO phantom and several head and neck cancer patients treated with tomotherapy and compared to TLD measurements and treatment plan doses to evaluate the performance of MOSFETs in a high gradient radiation field. The average calibration factor found was 0.345+/-2.5%cGy/mV for the high sensitivity MOSFETs tested and 0.901+/-2.4%cGy/mV for the standard sensitivity MOSFETs. MOSFET measured surface doses had an average agreement with ion chamber measurements of 1.55% for the high sensitivity MOSFET and 5.23% for the standard sensitivity MOSFET when averaged over all trials and field sizes tested. No significant dependence on field size was found for the standard sensitivity MOSFETs, however a maximum difference of 5.34% was found for the high sensitivity MOSFET calibration factors in the field sizes tested. Measurements made with MOSFETS on head and neck patients treated on a tomotherapy Hi-Art unit had an average agreement of (3.26+/-0.03)% with TLD measurements, however the average of the absolute difference between the MOSFET measurements and the treatment plan skin doses was (12.2+/-7.5)%. The MOSFET measured patient skin doses also had good reproducibility, with inter-fraction deviations ranging from 1.4% to 6.6%. Similar results were found from trials using a RANDO phantom. The MOSFETs performed well when used in the tomotherapy Hi-Art unit and did not increase the overall treatment set-up time when used for patient measurements. It was found that MOSFETs are suitable detectors for surface dose measurements in both conventional beam and tomotherapy treatments and they can provide valuable skin dose information in areas where the treatment planning system may not be accurate.

  10. Relative resilience to noise of standard and sequential approaches to measurement-based quantum computation

    NASA Astrophysics Data System (ADS)

    Gallagher, C. B.; Ferraro, A.

    2018-05-01

    A possible alternative to the standard model of measurement-based quantum computation (MBQC) is offered by the sequential model of MBQC—a particular class of quantum computation via ancillae. Although these two models are equivalent under ideal conditions, their relative resilience to noise in practical conditions is not yet known. We analyze this relationship for various noise models in the ancilla preparation and in the entangling-gate implementation. The comparison of the two models is performed utilizing both the gate infidelity and the diamond distance as figures of merit. Our results show that in the majority of instances the sequential model outperforms the standard one in regard to a universal set of operations for quantum computation. Further investigation is made into the performance of sequential MBQC in experimental scenarios, thus setting benchmarks for possible cavity-QED implementations.

  11. Black Carbon Measurement Intercomparison during the 2017 Black Carbon Shootout

    NASA Astrophysics Data System (ADS)

    Shingler, T.; Moore, R.; Winstead, E.; Robinson, C. E.; Shook, M.; Crosbie, E.; Ziemba, L. D.; Thornhill, K. L., II; Sorooshian, A.; Anderson, B. E.

    2017-12-01

    The NASA Langley Aerosol Research Group (LARGE) provides multiple black carbon (BC) based aerosol particle measurements and engine emission factors for airborne and ground-based field campaigns and laboratory studies. These datasets are made available to the general public where accuracy is key to enable further use in environmental assessments, models, and validation studies. Studies are needed to establish the accuracy and precision of BC measurements of particles with varying physical properties using a variety of detection techniques. Work is also needed to develop calibration and correction schemes for new sensors and to link these measurements to heritage instruments on which our understanding of BC emissions and characteristics has been established. A BC measurement intercomparison was performed at Langley Research Center using particles generated from a mini-CAST (Jing) diffusion flame soot generator. The particles were passed to instruments measuring optical absorption, extinction, scattering and black carbon mass. Filter based measurements of optical absorption were performed using a PSAP (Radiance Research) and a TAP (BMI). Absorption was also measured using two photoacoustic based instruments: the MSS-plus (AVL) and PASS-3 (DMT). Measurements of aerosol extinction were performed using three CAPS PM-ex (Aerodyne Research) instruments at multiple wavelengths. Two Artium LII-300 units (standard and high-sensitivity) were used to measure black carbon mass via laser incandescence. Black carbon measurements were correlated to mass collected concurrently on a filter and analyzed by OC/EC analysis (Sunset Labs). Black carbon quantification measurements are analyzed between instruments to assess agreement between platforms using manufacturer's calibration settings as well as after calibrations performed to a single standard soot source (mini-CAST). Sampling was also performed from behind a Falcon aircraft at multiple thrust settings and downwind of runway at an international airport with commercial takeoffs and landings.

  12. Conditional Standard Errors, Reliability and Decision Consistency of Performance Levels Using Polytomous IRT.

    ERIC Educational Resources Information Center

    Wang, Tianyou; And Others

    M. J. Kolen, B. A. Hanson, and R. L. Brennan (1992) presented a procedure for assessing the conditional standard error of measurement (CSEM) of scale scores using a strong true-score model. They also investigated the ways of using nonlinear transformation from number-correct raw score to scale score to equalize the conditional standard error along…

  13. X-ray Fluorescence Spectroscopy Study of Coating Thickness and Base Metal Composition

    NASA Technical Reports Server (NTRS)

    Rolin, T. D.; Leszczuk, Y.

    2008-01-01

    For electrical, electronic, and electromechanical (EEE) parts to be approved for space use, they must be able to meet safety standards approved by NASA. A fast, reliable, and precise method is needed to make sure these standards are met. Many EEE parts are coated in gold (Au) and nickel (Ni), and the thickness coating is crucial to a part s performance. A nondestructive method that is efficient in measuring coating thickness is x-ray fluorescence (XRF) spectroscopy. The XRF spectrometer is a machine designed to measure layer thickness and composition of single or multilayered samples. By understanding the limitations in the collection of the data by this method, accurate composition and thickness measurements can be obtained for samples with Au and Ni coatings. To understand the limitations of data found, measurements were taken with the XRF spectrometer and compared to true values of standard reference materials (SRM) that were National Institute of Standards and Technology (NIST) traceable. For every sample, six different parameters were varied to understand measurement error: coating/substrate combination, number of layers, counting interval, collimator size, coating thickness, and test area location. Each measurement was taken in accordance with standards set by the American Society for Testing and Materials (ASTM) International Standard B 568.

  14. Observation of the Higgs boson decay to a pair of τ leptons with the CMS detector

    NASA Astrophysics Data System (ADS)

    Sirunyan, A. M.; Tumasyan, A.; Adam, W.; Ambrogi, F.; Asilar, E.; Bergauer, T.; Brandstetter, J.; Brondolin, E.; Dragicevic, M.; Erö, J.; Flechl, M.; Friedl, M.; Frühwirth, R.; Ghete, V. M.; Grossmann, J.; Hrubec, J.; Jeitler, M.; König, A.; Krammer, N.; Krätschmer, I.; Liko, D.; Madlener, T.; Mikulec, I.; Pree, E.; Rabady, D.; Rad, N.; Rohringer, H.; Schieck, J.; Schöfbeck, R.; Spanring, M.; Spitzbart, D.; Waltenberger, W.; Wittmann, J.; Wulz, C.-E.; Zarucki, M.; Chekhovsky, V.; Mossolov, V.; Suarez Gonzalez, J.; De Wolf, E. A.; Di Croce, D.; Janssen, X.; Lauwers, J.; Van Haevermaet, H.; Van Mechelen, P.; Van Remortel, N.; Abu Zeid, S.; Blekman, F.; D'Hondt, J.; De Bruyn, I.; De Clercq, J.; Deroover, K.; Flouris, G.; Lontkovskyi, D.; Lowette, S.; Moortgat, S.; Moreels, L.; Python, Q.; Skovpen, K.; Tavernier, S.; Van Doninck, W.; Van Mulders, P.; Van Parijs, I.; Beghin, D.; Brun, H.; Clerbaux, B.; De Lentdecker, G.; Delannoy, H.; Fasanella, G.; Favart, L.; Goldouzian, R.; Grebenyuk, A.; Karapostoli, G.; Lenzi, T.; Luetic, J.; Maerschalk, T.; Marinov, A.; Randle-conde, A.; Seva, T.; Vander Velde, C.; Vanlaer, P.; Vannerom, D.; Yonamine, R.; Zenoni, F.; Zhang, F.; Cimmino, A.; Cornelis, T.; Dobur, D.; Fagot, A.; Gul, M.; Khvastunov, I.; Poyraz, D.; Roskas, C.; Salva, S.; Tytgat, M.; Verbeke, W.; Zaganidis, N.; Bakhshiansohi, H.; Bondu, O.; Brochet, S.; Bruno, G.; Caputo, C.; Caudron, A.; De Visscher, S.; Delaere, C.; Delcourt, M.; Francois, B.; Giammanco, A.; Jafari, A.; Komm, M.; Krintiras, G.; Lemaitre, V.; Magitteri, A.; Mertens, A.; Musich, M.; Piotrzkowski, K.; Quertenmont, L.; Vidal Marono, M.; Wertz, S.; Beliy, N.; Aldá Júnior, W. L.; Alves, F. L.; Alves, G. A.; Brito, L.; Correa Martins Junior, M.; Hensel, C.; Moraes, A.; Pol, M. E.; Rebello Teles, P.; Belchior Batista Das Chagas, E.; Carvalho, W.; Chinellato, J.; Coelho, E.; Custódio, A.; Da Costa, E. M.; Da Silveira, G. G.; De Jesus Damiao, D.; Fonseca De Souza, S.; Huertas Guativa, L. M.; Malbouisson, H.; Melo De Almeida, M.; Mora Herrera, C.; Mundim, L.; Nogima, H.; Santoro, A.; Sznajder, A.; Tonelli Manganote, E. J.; Torres Da Silva De Araujo, F.; Vilela Pereira, A.; Ahuja, S.; Bernardes, C. A.; Fernandez Perez Tomei, T. R.; Gregores, E. M.; Mercadante, P. G.; Novaes, S. F.; Padula, Sandra S.; Romero Abad, D.; Ruiz Vargas, J. C.; Aleksandrov, A.; Hadjiiska, R.; Iaydjiev, P.; Misheva, M.; Rodozov, M.; Shopova, M.; Stoykova, S.; Sultanov, G.; Dimitrov, A.; Glushkov, I.; Litov, L.; Pavlov, B.; Petkov, P.; Fang, W.; Gao, X.; Ahmad, M.; Bian, J. G.; Chen, G. M.; Chen, H. S.; Chen, M.; Chen, Y.; Jiang, C. H.; Leggat, D.; Liao, H.; Liu, Z.; Romeo, F.; Shaheen, S. M.; Spiezia, A.; Tao, J.; Wang, C.; Wang, Z.; Yazgan, E.; Zhang, H.; Zhang, S.; Zhao, J.; Ban, Y.; Chen, G.; Li, Q.; Liu, S.; Mao, Y.; Qian, S. J.; Wang, D.; Xu, Z.; Avila, C.; Cabrera, A.; Chaparro Sierra, L. F.; Florez, C.; González Hernández, C. F.; Ruiz Alvarez, J. D.; Courbon, B.; Godinovic, N.; Lelas, D.; Puljak, I.; Ribeiro Cipriano, P. M.; Sculac, T.; Antunovic, Z.; Kovac, M.; Brigljevic, V.; Ferencek, D.; Kadija, K.; Mesic, B.; Starodumov, A.; Susa, T.; Ather, M. W.; Attikis, A.; Mavromanolakis, G.; Mousa, J.; Nicolaou, C.; Ptochos, F.; Razis, P. A.; Rykaczewski, H.; Finger, M.; Finger, M.; Carrera Jarrin, E.; Assran, Y.; Elgammal, S.; Mahrous, A.; Dewanjee, R. K.; Kadastik, M.; Perrini, L.; Raidal, M.; Tiko, A.; Veelken, C.; Eerola, P.; Pekkanen, J.; Voutilainen, M.; Härkönen, J.; Järvinen, T.; Karimäki, V.; Kinnunen, R.; Lampén, T.; Lassila-Perini, K.; Lehti, S.; Lindén, T.; Luukka, P.; Tuominen, E.; Tuominiemi, J.; Tuovinen, E.; Talvitie, J.; Tuuva, T.; Besancon, M.; Couderc, F.; Dejardin, M.; Denegri, D.; Faure, J. L.; Ferri, F.; Ganjour, S.; Ghosh, S.; Givernaud, A.; Gras, P.; Hamel de Monchenault, G.; Jarry, P.; Kucher, I.; Locci, E.; Machet, M.; Malcles, J.; Negro, G.; Rander, J.; Rosowsky, A.; Sahin, M. Ö.; Titov, M.; Abdulsalam, A.; Amendola, C.; Antropov, I.; Baffioni, S.; Beaudette, F.; Busson, P.; Cadamuro, L.; Charlot, C.; Granier de Cassagnac, R.; Jo, M.; Lisniak, S.; Lobanov, A.; Martin Blanco, J.; Nguyen, M.; Ochando, C.; Ortona, G.; Paganini, P.; Pigard, P.; Salerno, R.; Sauvan, J. B.; Sirois, Y.; Stahl Leiton, A. G.; Strebler, T.; Yilmaz, Y.; Zabi, A.; Zghiche, A.; Agram, J.-L.; Andrea, J.; Bloch, D.; Brom, J.-M.; Buttignol, M.; Chabert, E. C.; Chanon, N.; Collard, C.; Conte, E.; Coubez, X.; Fontaine, J.-C.; Gelé, D.; Goerlach, U.; Jansová, M.; Le Bihan, A.-C.; Tonon, N.; Van Hove, P.; Gadrat, S.; Beauceron, S.; Bernet, C.; Boudoul, G.; Chierici, R.; Contardo, D.; Depasse, P.; El Mamouni, H.; Fay, J.; Finco, L.; Gascon, S.; Gouzevitch, M.; Grenier, G.; Ille, B.; Lagarde, F.; Laktineh, I. B.; Lethuillier, M.; Mirabito, L.; Pequegnot, A. L.; Perries, S.; Popov, A.; Sordini, V.; Vander Donckt, M.; Viret, S.; Khvedelidze, A.; Tsamalaidze, Z.; Autermann, C.; Feld, L.; Kiesel, M. K.; Klein, K.; Lipinski, M.; Preuten, M.; Schomakers, C.; Schulz, J.; Verlage, T.; Zhukov, V.; Albert, A.; Dietz-Laursonn, E.; Duchardt, D.; Endres, M.; Erdmann, M.; Erdweg, S.; Esch, T.; Fischer, R.; Güth, A.; Hamer, M.; Hebbeker, T.; Heidemann, C.; Hoepfner, K.; Knutzen, S.; Merschmeyer, M.; Meyer, A.; Millet, P.; Mukherjee, S.; Pook, T.; Radziej, M.; Reithler, H.; Rieger, M.; Scheuch, F.; Teyssier, D.; Thüer, S.; Flügge, G.; Kargoll, B.; Kress, T.; Künsken, A.; Lingemann, J.; Müller, T.; Nehrkorn, A.; Nowack, A.; Pistone, C.; Pooth, O.; Stahl, A.; Aldaya Martin, M.; Arndt, T.; Asawatangtrakuldee, C.; Beernaert, K.; Behnke, O.; Behrens, U.; Bermúdez Martínez, A.; Bin Anuar, A. A.; Borras, K.; Botta, V.; Campbell, A.; Connor, P.; Contreras-Campana, C.; Costanza, F.; Diez Pardos, C.; Eckerlin, G.; Eckstein, D.; Eichhorn, T.; Eren, E.; Gallo, E.; Garay Garcia, J.; Geiser, A.; Gizhko, A.; Grados Luyando, J. M.; Grohsjean, A.; Gunnellini, P.; Guthoff, M.; Harb, A.; Hauk, J.; Hempel, M.; Jung, H.; Kalogeropoulos, A.; Kasemann, M.; Keaveney, J.; Kleinwort, C.; Korol, I.; Krücker, D.; Lange, W.; Lelek, A.; Lenz, T.; Leonard, J.; Lipka, K.; Lohmann, W.; Mankel, R.; Melzer-Pellmann, I.-A.; Meyer, A. B.; Mittag, G.; Mnich, J.; Mussgiller, A.; Ntomari, E.; Pitzl, D.; Raspereza, A.; Roland, B.; Savitskyi, M.; Saxena, P.; Shevchenko, R.; Spannagel, S.; Stefaniuk, N.; Van Onsem, G. P.; Walsh, R.; Wen, Y.; Wichmann, K.; Wissing, C.; Zenaiev, O.; Bein, S.; Blobel, V.; Centis Vignali, M.; Dreyer, T.; Garutti, E.; Gonzalez, D.; Haller, J.; Hinzmann, A.; Hoffmann, M.; Karavdina, A.; Klanner, R.; Kogler, R.; Kovalchuk, N.; Kurz, S.; Lapsien, T.; Marchesini, I.; Marconi, D.; Meyer, M.; Niedziela, M.; Nowatschin, D.; Pantaleo, F.; Peiffer, T.; Perieanu, A.; Scharf, C.; Schleper, P.; Schmidt, A.; Schumann, S.; Schwandt, J.; Sonneveld, J.; Stadie, H.; Steinbrück, G.; Stober, F. M.; Stöver, M.; Tholen, H.; Troendle, D.; Usai, E.; Vanelderen, L.; Vanhoefer, A.; Vormwald, B.; Akbiyik, M.; Barth, C.; Baur, S.; Butz, E.; Caspart, R.; Chwalek, T.; Colombo, F.; De Boer, W.; Dierlamm, A.; Freund, B.; Friese, R.; Giffels, M.; Haitz, D.; Hartmann, F.; Heindl, S. M.; Husemann, U.; Kassel, F.; Kudella, S.; Mildner, H.; Mozer, M. U.; Müller, Th.; Plagge, M.; Quast, G.; Rabbertz, K.; Schröder, M.; Shvetsov, I.; Sieber, G.; Simonis, H. J.; Ulrich, R.; Wayand, S.; Weber, M.; Weiler, T.; Williamson, S.; Wöhrmann, C.; Wolf, R.; Anagnostou, G.; Daskalakis, G.; Geralis, T.; Giakoumopoulou, V. A.; Kyriakis, A.; Loukas, D.; Topsis-Giotis, I.; Karathanasis, G.; Kesisoglou, S.; Panagiotou, A.; Saoulidou, N.; Kousouris, K.; Evangelou, I.; Foudas, C.; Kokkas, P.; Mallios, S.; Manthos, N.; Papadopoulos, I.; Paradas, E.; Strologas, J.; Triantis, F. A.; Csanad, M.; Filipovic, N.; Pasztor, G.; Veres, G. I.; Bencze, G.; Hajdu, C.; Horvath, D.; Hunyadi, Á.; Sikler, F.; Veszpremi, V.; Zsigmond, A. J.; Beni, N.; Czellar, S.; Karancsi, J.; Makovec, A.; Molnar, J.; Szillasi, Z.; Bartók, M.; Raics, P.; Trocsanyi, Z. L.; Ujvari, B.; Choudhury, S.; Komaragiri, J. R.; Bahinipati, S.; Bhowmik, S.; Mal, P.; Mandal, K.; Nayak, A.; Sahoo, D. K.; Sahoo, N.; Swain, S. K.; Bansal, S.; Beri, S. B.; Bhatnagar, V.; Chawla, R.; Dhingra, N.; Kalsi, A. K.; Kaur, A.; Kaur, M.; Kumar, R.; Kumari, P.; Mehta, A.; Singh, J. B.; Walia, G.; Kumar, Ashok; Shah, Aashaq; Bhardwaj, A.; Chauhan, S.; Choudhary, B. C.; Garg, R. B.; Keshri, S.; Kumar, A.; Malhotra, S.; Naimuddin, M.; Ranjan, K.; Sharma, R.; Bhardwaj, R.; Bhattacharya, R.; Bhattacharya, S.; Bhawandeep, U.; Dey, S.; Dutt, S.; Dutta, S.; Ghosh, S.; Majumdar, N.; Modak, A.; Mondal, K.; Mukhopadhyay, S.; Nandan, S.; Purohit, A.; Roy, A.; Roy, D.; Roy Chowdhury, S.; Sarkar, S.; Sharan, M.; Thakur, S.; Behera, P. K.; Chudasama, R.; Dutta, D.; Jha, V.; Kumar, V.; Mohanty, A. K.; Netrakanti, P. K.; Pant, L. M.; Shukla, P.; Topkar, A.; Aziz, T.; Dugad, S.; Mahakud, B.; Mitra, S.; Mohanty, G. B.; Sur, N.; Sutar, B.; Banerjee, S.; Bhattacharya, S.; Chatterjee, S.; Das, P.; Guchait, M.; Jain, Sa.; Kumar, S.; Maity, M.; Majumder, G.; Mazumdar, K.; Sarkar, T.; Wickramage, N.; Chauhan, S.; Dube, S.; Hegde, V.; Kapoor, A.; Kothekar, K.; Pandey, S.; Rane, A.; Sharma, S.; Chenarani, S.; Eskandari Tadavani, E.; Etesami, S. M.; Khakzad, M.; Mohammadi Najafabadi, M.; Naseri, M.; Paktinat Mehdiabadi, S.; Rezaei Hosseinabadi, F.; Safarzadeh, B.; Zeinali, M.; Felcini, M.; Grunewald, M.; Abbrescia, M.; Calabria, C.; Colaleo, A.; Creanza, D.; Cristella, L.; De Filippis, N.; De Palma, M.; Errico, F.; Fiore, L.; Iaselli, G.; Lezki, S.; Maggi, G.; Maggi, M.; Miniello, G.; My, S.; Nuzzo, S.; Pompili, A.; Pugliese, G.; Radogna, R.; Ranieri, A.; Selvaggi, G.; Sharma, A.; Silvestris, L.; Venditti, R.; Verwilligen, P.; Abbiendi, G.; Battilana, C.; Bonacorsi, D.; Braibant-Giacomelli, S.; Campanini, R.; Capiluppi, P.; Castro, A.; Cavallo, F. R.; Chhibra, S. S.; Codispoti, G.; Cuffiani, M.; Dallavalle, G. M.; Fabbri, F.; Fanfani, A.; Fasanella, D.; Giacomelli, P.; Grandi, C.; Guiducci, L.; Marcellini, S.; Masetti, G.; Montanari, A.; Navarria, F. L.; Perrotta, A.; Rossi, A. M.; Rovelli, T.; Siroli, G. P.; Tosi, N.; Albergo, S.; Costa, S.; Di Mattia, A.; Giordano, F.; Potenza, R.; Tricomi, A.; Tuve, C.; Barbagli, G.; Chatterjee, K.; Ciulli, V.; Civinini, C.; D'Alessandro, R.; Focardi, E.; Lenzi, P.; Meschini, M.; Paoletti, S.; Russo, L.; Sguazzoni, G.; Strom, D.; Viliani, L.; Benussi, L.; Bianco, S.; Fabbri, F.; Piccolo, D.; Primavera, F.; Calvelli, V.; Ferro, F.; Robutti, E.; Tosi, S.; Benaglia, A.; Brianza, L.; Brivio, F.; Ciriolo, V.; Dinardo, M. E.; Fiorendi, S.; Gennai, S.; Ghezzi, A.; Govoni, P.; Malberti, M.; Malvezzi, S.; Manzoni, R. A.; Menasce, D.; Moroni, L.; Paganoni, M.; Pauwels, K.; Pedrini, D.; Pigazzini, S.; Ragazzi, S.; Redaelli, N.; Tabarelli de Fatis, T.; Buontempo, S.; Cavallo, N.; Di Guida, S.; Fabozzi, F.; Fienga, F.; Iorio, A. O. M.; Khan, W. A.; Lista, L.; Meola, S.; Paolucci, P.; Sciacca, C.; Thyssen, F.; Azzi, P.; Bacchetta, N.; Benato, L.; Bisello, D.; Boletti, A.; Bragagnolo, A.; Carlin, R.; Carvalho Antunes De Oliveira, A.; Checchia, P.; Dall'Osso, M.; De Castro Manzano, P.; Dorigo, T.; Dosselli, U.; Gasparini, F.; Gasparini, U.; Lacaprara, S.; Lujan, P.; Margoni, M.; Meneguzzo, A. T.; Pozzobon, N.; Ronchese, P.; Rossin, R.; Simonetto, F.; Torassa, E.; Ventura, S.; Zanetti, M.; Zotto, P.; Braghieri, A.; Magnani, A.; Montagna, P.; Ratti, S. P.; Re, V.; Ressegotti, M.; Riccardi, C.; Salvini, P.; Vai, I.; Vitulo, P.; Alunni Solestizi, L.; Biasini, M.; Bilei, G. M.; Cecchi, C.; Ciangottini, D.; Fanò, L.; Lariccia, P.; Leonardi, R.; Manoni, E.; Mantovani, G.; Mariani, V.; Menichelli, M.; Rossi, A.; Santocchia, A.; Spiga, D.; Androsov, K.; Azzurri, P.; Bagliesi, G.; Boccali, T.; Borrello, L.; Castaldi, R.; Ciocci, M. A.; Dell'Orso, R.; Fedi, G.; Giannini, L.; Giassi, A.; Grippo, M. T.; Ligabue, F.; Lomtadze, T.; Manca, E.; Mandorli, G.; Martini, L.; Messineo, A.; Palla, F.; Rizzi, A.; Savoy-Navarro, A.; Spagnolo, P.; Tenchini, R.; Tonelli, G.; Venturi, A.; Verdini, P. G.; Barone, L.; Cavallari, F.; Cipriani, M.; Daci, N.; Del Re, D.; Di Marco, E.; Diemoz, M.; Gelli, S.; Longo, E.; Margaroli, F.; Marzocchi, B.; Meridiani, P.; Organtini, G.; Paramatti, R.; Preiato, F.; Rahatlou, S.; Rovelli, C.; Santanastasio, F.; Amapane, N.; Arcidiacono, R.; Argiro, S.; Arneodo, M.; Bartosik, N.; Bellan, R.; Biino, C.; Cartiglia, N.; Cenna, F.; Costa, M.; Covarelli, R.; Degano, A.; Demaria, N.; Kiani, B.; Mariotti, C.; Maselli, S.; Migliore, E.; Monaco, V.; Monteil, E.; Monteno, M.; Obertino, M. M.; Pacher, L.; Pastrone, N.; Pelliccioni, M.; Pinna Angioni, G. L.; Ravera, F.; Romero, A.; Ruspa, M.; Sacchi, R.; Shchelina, K.; Sola, V.; Solano, A.; Staiano, A.; Traczyk, P.; Belforte, S.; Casarsa, M.; Cossutti, F.; Della Ricca, G.; Zanetti, A.; Kim, D. H.; Kim, G. N.; Kim, M. S.; Lee, J.; Lee, S.; Lee, S. W.; Moon, C. S.; Oh, Y. D.; Sekmen, S.; Son, D. C.; Yang, Y. C.; Lee, A.; Kim, H.; Moon, D. H.; Oh, G.; Brochero Cifuentes, J. A.; Goh, J.; Kim, T. J.; Cho, S.; Choi, S.; Go, Y.; Gyun, D.; Ha, S.; Hong, B.; Jo, Y.; Kim, Y.; Lee, K.; Lee, K. S.; Lee, S.; Lim, J.; Park, S. K.; Roh, Y.; Almond, J.; Kim, J.; Kim, J. S.; Lee, H.; Lee, K.; Nam, K.; Oh, S. B.; Radburn-Smith, B. C.; Seo, S. h.; Yang, U. K.; Yoo, H. D.; Yu, G. B.; Choi, M.; Kim, H.; Kim, J. H.; Lee, J. S. H.; Park, I. C.; Choi, Y.; Hwang, C.; Lee, J.; Yu, I.; Dudenas, V.; Juodagalvis, A.; Vaitkus, J.; Ahmed, I.; Ibrahim, Z. A.; Md Ali, M. A. B.; Mohamad Idris, F.; Wan Abdullah, W. A. T.; Yusli, M. N.; Zolkapli, Z.; Reyes-Almanza, R.; Ramirez-Sanchez, G.; Duran-Osuna, M. C.; Castilla-Valdez, H.; De La Cruz-Burelo, E.; Heredia-De La Cruz, I.; Rabadan-Trejo, R. I.; Lopez-Fernandez, R.; Mejia Guisao, J.; Sanchez-Hernandez, A.; Carrillo Moreno, S.; Oropeza Barrera, C.; Vazquez Valencia, F.; Pedraza, I.; Salazar Ibarguen, H. A.; Uribe Estrada, C.; Morelos Pineda, A.; Krofcheck, D.; Butler, P. H.; Ahmad, A.; Ahmad, M.; Hassan, Q.; Hoorani, H. R.; Saddique, A.; Shah, M. A.; Shoaib, M.; Waqas, M.; Bialkowska, H.; Bluj, M.; Boimska, B.; Frueboes, T.; Górski, M.; Kazana, M.; Nawrocki, K.; Szleper, M.; Zalewski, P.; Bunkowski, K.; Byszuk, A.; Doroba, K.; Kalinowski, A.; Konecki, M.; Krolikowski, J.; Misiura, M.; Olszewski, M.; Pyskir, A.; Walczak, M.; Bargassa, P.; Beirão Da Cruz E Silva, C.; Di Francesco, A.; Faccioli, P.; Galinhas, B.; Gallinaro, M.; Hollar, J.; Leonardo, N.; Lloret Iglesias, L.; Nemallapudi, M. V.; Seixas, J.; Strong, G.; Toldaiev, O.; Vadruccio, D.; Varela, J.; Afanasiev, S.; Bunin, P.; Gavrilenko, M.; Golutvin, I.; Gorbunov, I.; Kamenev, A.; Karjavin, V.; Lanev, A.; Malakhov, A.; Matveev, V.; Palichik, V.; Perelygin, V.; Shmatov, S.; Shulha, S.; Skatchkov, N.; Smirnov, V.; Voytishin, N.; Zarubin, A.; Ivanov, Y.; Kim, V.; Kuznetsova, E.; Levchenko, P.; Murzin, V.; Oreshkin, V.; Smirnov, I.; Sulimov, V.; Uvarov, L.; Vavilov, S.; Vorobyev, A.; Andreev, Yu.; Dermenev, A.; Gninenko, S.; Golubev, N.; Karneyeu, A.; Kirsanov, M.; Krasnikov, N.; Pashenkov, A.; Tlisov, D.; Toropin, A.; Epshteyn, V.; Gavrilov, V.; Lychkovskaya, N.; Popov, V.; Pozdnyakov, I.; Safronov, G.; Spiridonov, A.; Stepennov, A.; Toms, M.; Vlasov, E.; Zhokin, A.; Aushev, T.; Bylinkin, A.; Chadeeva, M.; Parygin, P.; Philippov, D.; Polikarpov, S.; Popova, E.; Rusinov, V.; Andreev, V.; Azarkin, M.; Dremin, I.; Kirakosyan, M.; Terkulov, A.; Baskakov, A.; Belyaev, A.; Boos, E.; Bunichev, V.; Dubinin, M.; Dudko, L.; Ershov, A.; Gribushin, A.; Klyukhin, V.; Kodolova, O.; Lokhtin, I.; Miagkov, I.; Obraztsov, S.; Petrushanko, S.; Savrin, V.; Blinov, V.; Skovpen, Y.; Shtol, D.; Azhgirey, I.; Bayshev, I.; Bitioukov, S.; Elumakhov, D.; Kachanov, V.; Kalinin, A.; Konstantinov, D.; Petrov, V.; Ryutin, R.; Sobol, A.; Troshin, S.; Tyurin, N.; Uzunian, A.; Volkov, A.; Adzic, P.; Cirkovic, P.; Devetak, D.; Dordevic, M.; Milosevic, J.; Rekovic, V.; Alcaraz Maestre, J.; Barrio Luna, M.; Cerrada, M.; Colino, N.; De La Cruz, B.; Delgado Peris, A.; Escalante Del Valle, A.; Fernandez Bedoya, C.; Fernández Ramos, J. P.; Flix, J.; Fouz, M. C.; Garcia-Abia, P.; Gonzalez Lopez, O.; Goy Lopez, S.; Hernandez, J. M.; Josa, M. I.; Moran, D.; Pérez-Calero Yzquierdo, A.; Puerta Pelayo, J.; Quintario Olmeda, A.; Redondo, I.; Romero, L.; Soares, M. S.; Álvarez Fernández, A.; de Trocóniz, J. F.; Missiroli, M.; Cuevas, J.; Erice, C.; Fernandez Menendez, J.; Gonzalez Caballero, I.; González Fernández, J. R.; Palencia Cortezon, E.; Sanchez Cruz, S.; Vischia, P.; Vizan Garcia, J. M.; Cabrillo, I. J.; Calderon, A.; Chazin Quero, B.; Curras, E.; Duarte Campderros, J.; Fernandez, M.; Garcia-Ferrero, J.; Gomez, G.; Lopez Virto, A.; Marco, J.; Martinez Rivero, C.; Martinez Ruiz del Arbol, P.; Matorras, F.; Piedra Gomez, J.; Rodrigo, T.; Ruiz-Jimeno, A.; Scodellaro, L.; Trevisani, N.; Vila, I.; Vilar Cortabitarte, R.; Abbaneo, D.; Auffray, E.; Baillon, P.; Ball, A. H.; Barney, D.; Bianco, M.; Bloch, P.; Bocci, A.; Botta, C.; Camporesi, T.; Castello, R.; Cepeda, M.; Cerminara, G.; Chapon, E.; Chen, Y.; d'Enterria, D.; Dabrowski, A.; Daponte, V.; David, A.; De Gruttola, M.; De Roeck, A.; Dobson, M.; Dorney, B.; du Pree, T.; Dünser, M.; Dupont, N.; Elliott-Peisert, A.; Everaerts, P.; Fallavollita, F.; Franzoni, G.; Fulcher, J.; Funk, W.; Gigi, D.; Gilbert, A.; Gill, K.; Glege, F.; Gulhan, D.; Harris, P.; Hegeman, J.; Innocente, V.; Janot, P.; Karacheban, O.; Kieseler, J.; Kirschenmann, H.; Knünz, V.; Kornmayer, A.; Kortelainen, M. J.; Krammer, M.; Lange, C.; Lecoq, P.; Lourenço, C.; Lucchini, M. T.; Malgeri, L.; Mannelli, M.; Martelli, A.; Meijers, F.; Merlin, J. A.; Mersi, S.; Meschi, E.; Milenovic, P.; Moortgat, F.; Mulders, M.; Neugebauer, H.; Ngadiuba, J.; Orfanelli, S.; Orsini, L.; Pape, L.; Perez, E.; Peruzzi, M.; Petrilli, A.; Petrucciani, G.; Pfeiffer, A.; Pierini, M.; Racz, A.; Reis, T.; Rolandi, G.; Rovere, M.; Sakulin, H.; Schäfer, C.; Schwick, C.; Seidel, M.; Selvaggi, M.; Sharma, A.; Silva, P.; Sphicas, P.; Stakia, A.; Steggemann, J.; Stoye, M.; Tosi, M.; Treille, D.; Triossi, A.; Tsirou, A.; Veckalns, V.; Verweij, M.; Zeuner, W. D.; Bertl, W.; Caminada, L.; Deiters, K.; Erdmann, W.; Horisberger, R.; Ingram, Q.; Kaestli, H. C.; Kotlinski, D.; Langenegger, U.; Rohe, T.; Wiederkehr, S. A.; Bäni, L.; Berger, P.; Bianchini, L.; Casal, B.; Dissertori, G.; Dittmar, M.; Donegà, M.; Grab, C.; Heidegger, C.; Hits, D.; Hoss, J.; Kasieczka, G.; Klijnsma, T.; Lustermann, W.; Mangano, B.; Marionneau, M.; Meinhard, M. T.; Meister, D.; Micheli, F.; Musella, P.; Nessi-Tedaldi, F.; Pandolfi, F.; Pata, J.; Pauss, F.; Perrin, G.; Perrozzi, L.; Quittnat, M.; Reichmann, M.; Schönenberger, M.; Shchutska, L.; Tavolaro, V. R.; Theofilatos, K.; Vesterbacka Olsson, M. L.; Wallny, R.; Zhu, D. H.; Aarrestad, T. K.; Amsler, C.; Canelli, M. F.; De Cosa, A.; Del Burgo, R.; Donato, S.; Galloni, C.; Hreus, T.; Kilminster, B.; Pinna, D.; Rauco, G.; Robmann, P.; Salerno, D.; Seitz, C.; Takahashi, Y.; Zucchetta, A.; Candelise, V.; Doan, T. H.; Jain, Sh.; Khurana, R.; Kuo, C. M.; Lin, W.; Pozdnyakov, A.; Yu, S. S.; Kumar, Arun; Chang, P.; Chao, Y.; Chen, K. F.; Chen, P. H.; Fiori, F.; Hsiung, Y.; Liu, Y. F.; Lu, R.-S.; Paganis, E.; Psallidas, A.; Steen, A.; Tsai, J. f.; Asavapibhop, B.; Kovitanggoon, K.; Singh, G.; Srimanobhas, N.; Boran, F.; Cerci, S.; Damarseckin, S.; Demiroglu, Z. S.; Dozen, C.; Dumanoglu, I.; Girgis, S.; Gokbulut, G.; Guler, Y.; Hos, I.; Kangal, E. E.; Kara, O.; Kayis Topaksu, A.; Kiminsu, U.; Oglakci, M.; Onengut, G.; Ozdemir, K.; Sunar Cerci, D.; Tali, B.; Turkcapar, S.; Zorbakir, I. S.; Zorbilmez, C.; Bilin, B.; Karapinar, G.; Ocalan, K.; Yalvac, M.; Zeyrek, M.; Gülmez, E.; Kaya, M.; Kaya, O.; Tekten, S.; Yetkin, E. A.; Agaras, M. N.; Atay, S.; Cakir, A.; Cankocak, K.; Grynyov, B.; Levchuk, L.; Aggleton, R.; Ball, F.; Beck, L.; Brooke, J. J.; Burns, D.; Clement, E.; Cussans, D.; Davignon, O.; Flacher, H.; Goldstein, J.; Grimes, M.; Heath, G. P.; Heath, H. F.; Jacob, J.; Kreczko, L.; Lucas, C.; Newbold, D. M.; Paramesvaran, S.; Poll, A.; Sakuma, T.; Seif El Nasr-storey, S.; Smith, D.; Smith, V. J.; Bell, K. W.; Belyaev, A.; Brew, C.; Brown, R. M.; Calligaris, L.; Cieri, D.; Cockerill, D. J. A.; Coughlan, J. A.; Harder, K.; Harper, S.; Olaiya, E.; Petyt, D.; Shepherd-Themistocleous, C. H.; Thea, A.; Tomalin, I. R.; Williams, T.; Auzinger, G.; Bainbridge, R.; Borg, J.; Breeze, S.; Buchmuller, O.; Bundock, A.; Casasso, S.; Citron, M.; Colling, D.; Corpe, L.; Dauncey, P.; Davies, G.; De Wit, A.; Della Negra, M.; Di Maria, R.; Elwood, A.; Haddad, Y.; Hall, G.; Iles, G.; James, T.; Lane, R.; Laner, C.; Lyons, L.; Magnan, A.-M.; Malik, S.; Mastrolorenzo, L.; Matsushita, T.; Nash, J.; Nikitenko, A.; Palladino, V.; Pesaresi, M.; Raymond, D. M.; Richards, A.; Rose, A.; Scott, E.; Seez, C.; Shtipliyski, A.; Summers, S.; Tapper, A.; Uchida, K.; Vazquez Acosta, M.; Virdee, T.; Wardle, N.; Winterbottom, D.; Wright, J.; Zenz, S. C.; Cole, J. E.; Hobson, P. R.; Khan, A.; Kyberd, P.; Reid, I. D.; Symonds, P.; Teodorescu, L.; Turner, M.; Borzou, A.; Call, K.; Dittmann, J.; Hatakeyama, K.; Liu, H.; Pastika, N.; Smith, C.; Bartek, R.; Dominguez, A.; Buccilli, A.; Cooper, S. I.; Henderson, C.; Rumerio, P.; West, C.; Arcaro, D.; Avetisyan, A.; Bose, T.; Gastler, D.; Rankin, D.; Richardson, C.; Rohlf, J.; Sulak, L.; Zou, D.; Benelli, G.; Cutts, D.; Garabedian, A.; Hakala, J.; Heintz, U.; Hogan, J. M.; Kwok, K. H. M.; Laird, E.; Landsberg, G.; Mao, Z.; Narain, M.; Pazzini, J.; Piperov, S.; Sagir, S.; Syarif, R.; Yu, D.; Band, R.; Brainerd, C.; Burns, D.; Calderon De La Barca Sanchez, M.; Chertok, M.; Conway, J.; Conway, R.; Cox, P. T.; Erbacher, R.; Flores, C.; Funk, G.; Gardner, M.; Ko, W.; Lander, R.; Mclean, C.; Mulhearn, M.; Pellett, D.; Pilot, J.; Shalhout, S.; Shi, M.; Smith, J.; Stolp, D.; Tos, K.; Tripathi, M.; Wang, Z.; Bachtis, M.; Bravo, C.; Cousins, R.; Dasgupta, A.; Florent, A.; Hauser, J.; Ignatenko, M.; Mccoll, N.; Regnard, S.; Saltzberg, D.; Schnaible, C.; Valuev, V.; Bouvier, E.; Burt, K.; Clare, R.; Ellison, J.; Gary, J. W.; Ghiasi Shirazi, S. M. A.; Hanson, G.; Heilman, J.; Jandir, P.; Kennedy, E.; Lacroix, F.; Long, O. R.; Olmedo Negrete, M.; Paneva, M. I.; Shrinivas, A.; Si, W.; Wang, L.; Wei, H.; Wimpenny, S.; Yates, B. R.; Branson, J. G.; Cittolin, S.; Derdzinski, M.; Gerosa, R.; Hashemi, B.; Holzner, A.; Klein, D.; Kole, G.; Krutelyov, V.; Letts, J.; Macneill, I.; Masciovecchio, M.; Olivito, D.; Padhi, S.; Pieri, M.; Sani, M.; Sharma, V.; Simon, S.; Tadel, M.; Vartak, A.; Wasserbaech, S.; Wood, J.; Würthwein, F.; Yagil, A.; Zevi Della Porta, G.; Amin, N.; Bhandari, R.; Bradmiller-Feld, J.; Campagnari, C.; Dishaw, A.; Dutta, V.; Franco Sevilla, M.; George, C.; Golf, F.; Gouskos, L.; Gran, J.; Heller, R.; Incandela, J.; Mullin, S. D.; Ovcharova, A.; Qu, H.; Richman, J.; Stuart, D.; Suarez, I.; Yoo, J.; Anderson, D.; Bendavid, J.; Bornheim, A.; Lawhorn, J. M.; Newman, H. B.; Nguyen, T.; Pena, C.; Spiropulu, M.; Vlimant, J. R.; Xie, S.; Zhang, Z.; Zhu, R. Y.; Andrews, M. B.; Ferguson, T.; Mudholkar, T.; Paulini, M.; Russ, J.; Sun, M.; Vogel, H.; Vorobiev, I.; Weinberg, M.; Cumalat, J. P.; Ford, W. T.; Jensen, F.; Johnson, A.; Krohn, M.; Leontsinis, S.; Mulholland, T.; Stenson, K.; Wagner, S. R.; Alexander, J.; Chaves, J.; Chu, J.; Dittmer, S.; Mcdermott, K.; Mirman, N.; Patterson, J. R.; Rinkevicius, A.; Ryd, A.; Skinnari, L.; Soffi, L.; Tan, S. M.; Tao, Z.; Thom, J.; Tucker, J.; Wittich, P.; Zientek, M.; Abdullin, S.; Albrow, M.; Alyari, M.; Apollinari, G.; Apresyan, A.; Apyan, A.; Banerjee, S.; Bauerdick, L. A. T.; Beretvas, A.; Berryhill, J.; Bhat, P. C.; Bolla, G.; Burkett, K.; Butler, J. N.; Canepa, A.; Cerati, G. B.; Cheung, H. W. K.; Chlebana, F.; Cremonesi, M.; Duarte, J.; Elvira, V. D.; Freeman, J.; Gecse, Z.; Gottschalk, E.; Gray, L.; Green, D.; Grünendahl, S.; Gutsche, O.; Harris, R. M.; Hasegawa, S.; Hirschauer, J.; Hu, Z.; Jayatilaka, B.; Jindariani, S.; Johnson, M.; Joshi, U.; Klima, B.; Kreis, B.; Lammel, S.; Lincoln, D.; Lipton, R.; Liu, M.; Liu, T.; Lopes De Sá, R.; Lykken, J.; Maeshima, K.; Magini, N.; Marraffino, J. M.; Maruyama, S.; Mason, D.; McBride, P.; Merkel, P.; Mrenna, S.; Nahn, S.; O'Dell, V.; Pedro, K.; Prokofyev, O.; Rakness, G.; Ristori, L.; Schneider, B.; Sexton-Kennedy, E.; Soha, A.; Spalding, W. J.; Spiegel, L.; Stoynev, S.; Strait, J.; Strobbe, N.; Taylor, L.; Tkaczyk, S.; Tran, N. V.; Uplegger, L.; Vaandering, E. W.; Vernieri, C.; Verzocchi, M.; Vidal, R.; Wang, M.; Weber, H. A.; Whitbeck, A.; Acosta, D.; Avery, P.; Bortignon, P.; Bourilkov, D.; Brinkerhoff, A.; Carnes, A.; Carver, M.; Curry, D.; Field, R. D.; Furic, I. K.; Konigsberg, J.; Korytov, A.; Kotov, K.; Ma, P.; Matchev, K.; Mei, H.; Mitselmakher, G.; Rank, D.; Sperka, D.; Terentyev, N.; Thomas, L.; Wang, J.; Wang, S.; Yelton, J.; Joshi, Y. R.; Linn, S.; Markowitz, P.; Rodriguez, J. L.; Ackert, A.; Adams, T.; Askew, A.; Hagopian, S.; Hagopian, V.; Johnson, K. F.; Kolberg, T.; Martinez, G.; Perry, T.; Prosper, H.; Saha, A.; Santra, A.; Sharma, V.; Yohay, R.; Baarmand, M. M.; Bhopatkar, V.; Colafranceschi, S.; Hohlmann, M.; Noonan, D.; Roy, T.; Yumiceva, F.; Adams, M. R.; Apanasevich, L.; Berry, D.; Betts, R. R.; Cavanaugh, R.; Chen, X.; Evdokimov, O.; Gerber, C. E.; Hangal, D. A.; Hofman, D. J.; Jung, K.; Kamin, J.; Sandoval Gonzalez, I. D.; Tonjes, M. B.; Trauger, H.; Varelas, N.; Wang, H.; Wu, Z.; Zhang, J.; Bilki, B.; Clarida, W.; Dilsiz, K.; Durgut, S.; Gandrajula, R. P.; Haytmyradov, M.; Khristenko, V.; Merlo, J.-P.; Mermerkaya, H.; Mestvirishvili, A.; Moeller, A.; Nachtman, J.; Ogul, H.; Onel, Y.; Ozok, F.; Penzo, A.; Snyder, C.; Tiras, E.; Wetzel, J.; Yi, K.; Blumenfeld, B.; Cocoros, A.; Eminizer, N.; Fehling, D.; Feng, L.; Gritsan, A. V.; Maksimovic, P.; Roskes, J.; Sarica, U.; Swartz, M.; Xiao, M.; You, C.; Al-bataineh, A.; Baringer, P.; Bean, A.; Boren, S.; Bowen, J.; Castle, J.; Khalil, S.; Kropivnitskaya, A.; Majumder, D.; Mcbrayer, W.; Murray, M.; Royon, C.; Sanders, S.; Schmitz, E.; Tapia Takaki, J. D.; Wang, Q.; Ivanov, A.; Kaadze, K.; Maravin, Y.; Mohammadi, A.; Saini, L. K.; Skhirtladze, N.; Toda, S.; Rebassoo, F.; Wright, D.; Anelli, C.; Baden, A.; Baron, O.; Belloni, A.; Calvert, B.; Eno, S. C.; Ferraioli, C.; Hadley, N. J.; Jabeen, S.; Jeng, G. Y.; Kellogg, R. G.; Kunkle, J.; Mignerey, A. C.; Ricci-Tam, F.; Shin, Y. H.; Skuja, A.; Tonwar, S. C.; Abercrombie, D.; Allen, B.; Azzolini, V.; Barbieri, R.; Baty, A.; Bi, R.; Brandt, S.; Busza, W.; Cali, I. A.; D'Alfonso, M.; Demiragli, Z.; Gomez Ceballos, G.; Goncharov, M.; Hsu, D.; Iiyama, Y.; Innocenti, G. M.; Klute, M.; Kovalskyi, D.; Lai, Y. S.; Lee, Y.-J.; Levin, A.; Luckey, P. D.; Maier, B.; Marini, A. C.; Mcginn, C.; Mironov, C.; Narayanan, S.; Niu, X.; Paus, C.; Roland, C.; Roland, G.; Salfeld-Nebgen, J.; Stephans, G. S. F.; Tatar, K.; Velicanu, D.; Wang, J.; Wang, T. W.; Wyslouch, B.; Benvenuti, A. C.; Chatterjee, R. M.; Evans, A.; Hansen, P.; Kalafut, S.; Kubota, Y.; Lesko, Z.; Mans, J.; Nourbakhsh, S.; Ruckstuhl, N.; Rusack, R.; Turkewitz, J.; Acosta, J. G.; Oliveros, S.; Avdeeva, E.; Bloom, K.; Claes, D. R.; Fangmeier, C.; Gonzalez Suarez, R.; Kamalieddin, R.; Kravchenko, I.; Monroy, J.; Siado, J. E.; Snow, G. R.; Stieger, B.; Dolen, J.; Godshalk, A.; Harrington, C.; Iashvili, I.; Nguyen, D.; Parker, A.; Rappoccio, S.; Roozbahani, B.; Alverson, G.; Barberis, E.; Hortiangtham, A.; Massironi, A.; Morse, D. M.; Nash, D.; Orimoto, T.; Teixeira De Lima, R.; Trocino, D.; Wood, D.; Bhattacharya, S.; Charaf, O.; Hahn, K. A.; Mucia, N.; Odell, N.; Pollack, B.; Schmitt, M. H.; Sung, K.; Trovato, M.; Velasco, M.; Dev, N.; Hildreth, M.; Hurtado Anampa, K.; Jessop, C.; Karmgard, D. J.; Kellams, N.; Lannon, K.; Loukas, N.; Marinelli, N.; Meng, F.; Mueller, C.; Musienko, Y.; Planer, M.; Reinsvold, A.; Ruchti, R.; Smith, G.; Taroni, S.; Wayne, M.; Wolf, M.; Woodard, A.; Alimena, J.; Antonelli, L.; Bylsma, B.; Durkin, L. S.; Flowers, S.; Francis, B.; Hart, A.; Hill, C.; Ji, W.; Liu, B.; Luo, W.; Puigh, D.; Winer, B. L.; Wulsin, H. W.; Cooperstein, S.; Driga, O.; Elmer, P.; Hardenbrook, J.; Hebda, P.; Higginbotham, S.; Lange, D.; Luo, J.; Marlow, D.; Mei, K.; Ojalvo, I.; Olsen, J.; Palmer, C.; Piroué, P.; Stickland, D.; Tully, C.; Malik, S.; Norberg, S.; Barker, A.; Barnes, V. E.; Das, S.; Folgueras, S.; Gutay, L.; Jha, M. K.; Jones, M.; Jung, A. W.; Khatiwada, A.; Miller, D. H.; Neumeister, N.; Peng, C. C.; Schulte, J. F.; Sun, J.; Wang, F.; Xie, W.; Cheng, T.; Parashar, N.; Stupak, J.; Adair, A.; Akgun, B.; Chen, Z.; Ecklund, K. M.; Geurts, F. J. M.; Guilbaud, M.; Li, W.; Michlin, B.; Northup, M.; Padley, B. P.; Roberts, J.; Rorie, J.; Tu, Z.; Zabel, J.; Bodek, A.; de Barbaro, P.; Demina, R.; Duh, Y. t.; Ferbel, T.; Galanti, M.; Garcia-Bellido, A.; Han, J.; Hindrichs, O.; Khukhunaishvili, A.; Lo, K. H.; Tan, P.; Verzetti, M.; Ciesielski, R.; Goulianos, K.; Mesropian, C.; Agapitos, A.; Chou, J. P.; Gershtein, Y.; Gómez Espinosa, T. A.; Halkiadakis, E.; Heindl, M.; Hughes, E.; Kaplan, S.; Kunnawalkam Elayavalli, R.; Kyriacou, S.; Lath, A.; Montalvo, R.; Nash, K.; Osherson, M.; Saka, H.; Salur, S.; Schnetzer, S.; Sheffield, D.; Somalwar, S.; Stone, R.; Thomas, S.; Thomassen, P.; Walker, M.; Delannoy, A. G.; Foerster, M.; Heideman, J.; Riley, G.; Rose, K.; Spanier, S.; Thapa, K.; Bouhali, O.; Castaneda Hernandez, A.; Celik, A.; Dalchenko, M.; De Mattia, M.; Delgado, A.; Dildick, S.; Eusebi, R.; Gilmore, J.; Huang, T.; Kamon, T.; Mueller, R.; Pakhotin, Y.; Patel, R.; Perloff, A.; Perniè, L.; Rathjens, D.; Safonov, A.; Tatarinov, A.; Ulmer, K. A.; Akchurin, N.; Damgov, J.; De Guio, F.; Dudero, P. R.; Faulkner, J.; Gurpinar, E.; Kunori, S.; Lamichhane, K.; Lee, S. W.; Libeiro, T.; Peltola, T.; Undleeb, S.; Volobouev, I.; Wang, Z.; Greene, S.; Gurrola, A.; Janjam, R.; Johns, W.; Maguire, C.; Melo, A.; Ni, H.; Padeken, K.; Sheldon, P.; Tuo, S.; Velkovska, J.; Xu, Q.; Arenton, M. W.; Barria, P.; Cox, B.; Hirosky, R.; Joyce, M.; Ledovskoy, A.; Li, H.; Neu, C.; Sinthuprasith, T.; Wang, Y.; Wolfe, E.; Xia, F.; Harr, R.; Karchin, P. E.; Sturdy, J.; Zaleski, S.; Brodski, M.; Buchanan, J.; Caillol, C.; Dasu, S.; Dodd, L.; Duric, S.; Gomber, B.; Grothe, M.; Herndon, M.; Hervé, A.; Hussain, U.; Klabbers, P.; Lanaro, A.; Levine, A.; Long, K.; Loveless, R.; Pierro, G. A.; Polese, G.; Ruggles, T.; Savin, A.; Smith, N.; Smith, W. H.; Taylor, D.; Woods, N.; CMS Collaboration

    2018-04-01

    A measurement of the H → ττ signal strength is performed using events recorded in proton-proton collisions by the CMS experiment at the LHC in 2016 at a center-of-mass energy of 13TeV. The data set corresponds to an integrated luminosity of 35.9fb-1. The H → ττ signal is established with a significance of 4.9 standard deviations, to be compared to an expected significance of 4.7 standard deviations. The best fit of the product of the observed H → ττ signal production cross section and branching fraction is 1.09-0.26+0.27 times the standard model expectation. The combination with the corresponding measurement performed with data collected by the CMS experiment at center-of-mass energies of 7 and 8TeV leads to an observed significance of 5.9 standard deviations, equal to the expected significance. This is the first observation of Higgs boson decays to τ leptons by a single experiment.

  15. Low aerobic fitness and obesity are associated with lower standardized test scores in children.

    PubMed

    Roberts, Christian K; Freed, Benjamin; McCarthy, William J

    2010-05-01

    To investigate whether aerobic fitness and obesity in school children are associated with standardized test performance. Ethnically diverse (n = 1989) 5th, 7th, and 9th graders attending California schools comprised the sample. Aerobic fitness was determined by a 1-mile run/walk test; body mass index (BMI) was obtained from state-mandated measurements. California standardized test scores were obtained from the school district. Students whose mile run/walk times exceeded California Fitnessgram standards or whose BMI exceeded Centers for Disease Control sex- and age-specific body weight standards scored lower on California standardized math, reading, and language tests than students with desirable BMI status or fitness level, even after controlling for parent education among other covariates. Ethnic differences in standardized test scores were consistent with ethnic differences in obesity status and aerobic fitness. BMI-for-age was no longer a significant multivariate predictor when covariates included fitness level. Low aerobic fitness is common among youth and varies among ethnic groups, and aerobic fitness level predicts performance on standardized tests across ethnic groups. More research is needed to uncover the physiological mechanisms by which aerobic fitness may contribute to performance on standardized academic tests.

  16. Sensitivity of sensor-based sit-to-stand peak power to the effects of training leg strength, leg power and balance in older adults.

    PubMed

    Regterschot, G Ruben H; Folkersma, Marjanne; Zhang, Wei; Baldus, Heribert; Stevens, Martin; Zijlstra, Wiebren

    2014-01-01

    Increasing leg strength, leg power and overall balance can improve mobility and reduce fall risk. Sensor-based assessment of peak power during the sit-to-stand (STS) transfer may be useful for detecting changes in mobility and fall risk. Therefore, this study investigated whether sensor-based STS peak power and related measures are sensitive to the effects of increasing leg strength, leg power and overall balance in older adults. A further aim was to compare sensitivity between sensor-based STS measures and standard clinical measures of leg strength, leg power, balance, mobility and fall risk, following an exercise-based intervention. To achieve these aims, 26 older adults (age: 70-84 years) participated in an eight-week exercise program aimed at improving leg strength, leg power and balance. Before and after the intervention, performance on normal and fast STS transfers was evaluated with a hybrid motion sensor worn on the hip. In addition, standard clinical tests (isometric quadriceps strength, Timed Up and Go test, Berg Balance Scale) were performed. Standard clinical tests as well as sensor-based measures of peak power, maximal velocity and duration of normal and fast STS showed significant improvements. Sensor-based measurement of peak power, maximal velocity and duration of normal STS demonstrated a higher sensitivity (absolute standardized response mean (SRM): ≥ 0.69) to the effects of training leg strength, leg power and balance than standard clinical measures (absolute SRM: ≤ 0.61). Therefore, the presented sensor-based method appears to be useful for detecting changes in mobility and fall risk. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Developing hospital accreditation standards in Uganda.

    PubMed

    Galukande, Moses; Katamba, Achilles; Nakasujja, Noeline; Baingana, Rhona; Bateganya, Moses; Hagopian, Amy; Tavrow, Paula; Barnhart, Scott; Luboga, Sam

    2016-07-01

    Whereas accreditation is widely used as a tool to improve quality of healthcare in the developed world, it is a concept not well adapted in most developing countries for a host of reasons, including insufficient incentives, insufficient training and a shortage of human and material resources. The purpose of this paper is to describe refining use and outcomes of a self-assessment hospital accreditation tool developed for a resource-limited context. We invited 60 stakeholders to review a set of standards (from which a self-assessment tool was developed), and subsequently refined them to include 485 standards in 7 domains. We then invited 60 hospitals to test them. A study team traveled to each of the 40 hospitals that agreed to participate providing training and debrief the self-assessment. The study was completed in 8 weeks. Hospital self-assessments revealed hospitals were remarkably open to frank rating of their performance and willing to rank all 485 measures. Good performance was measured in outreach programs, availability of some types of equipment and running water, 24-h staff calls systems, clinical guidelines and waste segregation. Poor performance was measured in care for the vulnerable, staff living quarters, physician performance reviews, patient satisfaction surveys and sterilizing equipment. We have demonstrated the feasibility of a self-assessment approach to hospital standards in low-income country setting. This low-cost approach may be used as a good precursor to establishing a national accreditation body, as indicated by the Ministry's efforts to take the next steps. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  18. N400 Event-Related Potential and Standardized Measures of Reading in Late Elementary School Children: Correlated or Independent?

    PubMed Central

    Coch, Donna; Benoit, Clarisse

    2015-01-01

    We investigated whether and how standardized behavioral measures of reading and electrophysiological measures of reading were related in 72 typically developing, late elementary school children. Behavioral measures included standardized tests of spelling, phonological processing, vocabulary, comprehension, naming speed, and memory. Electrophysiological measures were composed of the amplitude of the N400 component of the event-related potential waveform elicited by real words, pseudowords, nonpronounceable letter strings, and strings of letter-like symbols (false fonts). The only significant brain-behavior correlations were between standard scores on the vocabulary test and N400 mean amplitude to real words (r = −.272) and pseudowords (r = −.235). We conclude that, while these specific sets of standardized behavioral and electrophysiological measures both provide an index of reading, for the most part, they are independent and draw upon different underlying processing resources. [T]o completely analyze what we do when we read… would be to describe very many of the most intricate workings of the human mind, as well as to unravel the tangled story of the most remarkable specific performance that civilization has learned in all its history(Huey, 1908/1968, p. 3). PMID:26346715

  19. [Breast cancer screening process indicators in Mexico: a case study].

    PubMed

    Uscanga-Sánchez, Santos; Torres-Mejía, Gabriela; Ángeles-Llerenas, Angélica; Domínguez-Malpica, Raúl; Lazcano-Ponce, Eduardo

    2014-01-01

    To identify, measure and compare the performance indicators of productivity, effective access and quality service for the early detection breast cancer program in Mexico. By means of a study case based on the 2011 Women Cancer Information System (SICAM), the indicators were measured and compared with the Mexican official standard NOM-041-SSA2-2011 and international standards. The analysis showed insufficient installed capacity (37%), low coverage in screening (15%), diagnostic evaluation (16%), biopsy (44%) and treatment (57%), and very low effectiveness in confirmed cases by the total number of screening mammograms performed (0.04%). There was no information available, from SICAM, to estimate the rest of the indicators proposed. Efficient health information systems are required in order to monitor indicators and generate performance observatories of screening programs.

  20. Can an Inquiry Approach Improve College Student Learning in a Teaching Laboratory?

    PubMed Central

    Cogan, John G.

    2009-01-01

    We present an inquiry-based, hands-on laboratory exercise on enzyme activity for an introductory college biology course for science majors. We measure student performance on a series of objective and subjective questions before and after completion of this exercise; we also measure performance of a similar cohort of students before and after completion of an existing, standard, “direct” exercise over the same topics. Although student performance on these questions increased significantly after completion of the inquiry exercise, it did not increase after completion of the control, standard exercise. Pressure to “cover” many complex topics as preparation for high-stakes examinations such as the Medical College Admissions Test may account for persistence of highly efficient, yet dubiously effective “cookbook” laboratory exercises in many science classes. PMID:19255136

  1. Experimental Performance of a Frequency Measurement Circuit.

    DTIC Science & Technology

    1984-12-01

    STANDARDS 1963-A NAVAL POSTGRADUATE SCHOOL Monterey, California N O In DTISEL ECTE. APR 26 1985 THESIS EXPERIMENTAL PERFORMANCE OF A FREQUENCY MEASUREMENT...CIRCUIT by CO George H. Eastwood December 198𔃾 Thesis Advisor: G. A. Myers * Approved for public release; distribution is unlimited. * 85 4 2 105...ACCESSION NO. 3. RECIPIENT’S CATALOG NUMBER 4. TITLE (and Subtitle) S. TYPE OF REPORT & PERIOD COVERED Experimental Performance of a Master’s Thesis

  2. Radiosonde pressure sensor performance - Evaluation using tracking radars

    NASA Technical Reports Server (NTRS)

    Parsons, C. L.; Norcross, G. A.; Brooks, R. L.

    1984-01-01

    The standard balloon-borne radiosonde employed for synoptic meteorology provides vertical profiles of temperature, pressure, and humidity as a function of elapsed time. These parameters are used in the hypsometric equation to calculate the geopotential altitude at each sampling point during the balloon's flight. It is important that the vertical location information be accurate. The present investigation was conducted with the objective to evaluate the altitude determination accuracy of the standard radiosonde throughout the entire balloon profile. The tests included two other commercially available pressure sensors to see if they could provide improved accuracy in the stratosphere. The pressure-measuring performance of standard baroswitches, premium baroswitches, and hypsometers in balloon-borne sondes was correlated with tracking radars. It was found that the standard and premium baroswitches perform well up to about 25 km altitude, while hypsometers provide more reliable data above 25 km.

  3. Developing physician pay arrangements: the cash and care equation.

    PubMed

    Levitch, J H

    1998-11-01

    Developing physician compensation packages that help a healthcare organization meet its business objectives while satisfying physician pay expectations requires new ways of linking pay to physician performance. Such compensation arrangements specifically should include pay tied to defined performance standards, compensation linked to group performance, performance incentives based on realistic, achievable goals, work performance measured by common criteria, and similar pay ensured for similar work. Final pay arrangements also should include items that are sometimes overlooked, such as fully delineated job responsibilities, performance measures aligned correctly with performance areas, and the value of benefits considered in the cash compensation levels.

  4. Function library programming to support B89 evaluation of Sheffield Apollo RS50 DCC (Direct Computer Control) CMM (Coordinate Measuring Machine)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frank, R.N.

    1990-02-28

    The Inspection Shop at Lawrence Livermore Lab recently purchased a Sheffield Apollo RS50 Direct Computer Control Coordinate Measuring Machine. The performance of the machine was specified to conform to B89 standard which relies heavily upon using the measuring machine in its intended manner to verify its accuracy (rather than parametric tests). Although it would be possible to use the interactive measurement system to perform these tasks, a more thorough and efficient job can be done by creating Function Library programs for certain tasks which integrate Hewlett-Packard Basic 5.0 language and calls to proprietary analysis and machine control routines. This combinationmore » provides efficient use of the measuring machine with a minimum of keyboard input plus an analysis of the data with respect to the B89 Standard rather than a CMM analysis which would require subsequent interpretation. This paper discusses some characteristics of the Sheffield machine control and analysis software and my use of H-P Basic language to create automated measurement programs to support the B89 performance evaluation of the CMM. 1 ref.« less

  5. Experimental Evaluation of High Performance Integrated Heat Pump

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, William A; Berry, Robert; Durfee, Neal

    2016-01-01

    Integrated heat pump (IHP) technology provides significant potential for energy savings and comfort improvement for residential buildings. In this study, we evaluate the performance of a high performance IHP that provides space heating, cooling, and water heating services. Experiments were conducted according to the ASHRAE Standard 206-2013 where 24 test conditions were identified in order to evaluate the IHP performance indices based on the airside performance. Empirical curve fits of the unit s compressor maps are used in conjunction with saturated condensing and evaporating refrigerant conditions to deduce the refrigerant mass flowrate, which, in turn was used to evaluate themore » refrigerant side performance as a check on the airside performance. Heat pump (compressor, fans, and controls) and water pump power were measured separately per requirements of Standard 206. The system was charged per the system manufacturer s specifications. System test results are presented for each operating mode. The overall IHP performance metrics are determined from the test results per the Standard 206 calculation procedures.« less

  6. Fieldwork measurement of indoor environmental quality (IEQ) in Malaysian platinum-rated green office buildings

    NASA Astrophysics Data System (ADS)

    Tharim, Asniza Hamimi Abdul; Samad, Muna Hanim Abdul; Ismail, Mazran

    2017-10-01

    An Indoor Environmental Quality (IEQ) fieldwork assessment was conducted in the Platinum-rated GBI office building located in Putrajaya Malaysia. The aim of the study is to determine the current indoor performance of the selected green office building. The field measurement consists of several IEQ parameters counted under the GBI Malaysia namely the Thermal Comfort of temperature, relative humidity, air movement and heat transfer as well as solar radiation. This field measurement also comprises of the measurement for the background noise, visual lighting and Indoor Air Quality (IAQ) focusing on the aspect of carbon dioxide concentration. All the selected indoor parameters were measured for the period of five working days and the results were compared to the Malaysian Standard. Findings of the field measurement show good indoor performance of the Platinum rated office building that complies with the GBI standard. It is hoped that the research findings will be beneficial for future design and construction of office building intended to be rated under the GBI Malaysia.

  7. Updated methodology for nuclear magnetic resonance characterization of shales

    NASA Astrophysics Data System (ADS)

    Washburn, Kathryn E.; Birdwell, Justin E.

    2013-08-01

    Unconventional petroleum resources, particularly in shales, are expected to play an increasingly important role in the world's energy portfolio in the coming years. Nuclear magnetic resonance (NMR), particularly at low-field, provides important information in the evaluation of shale resources. Most of the low-field NMR analyses performed on shale samples rely heavily on standard T1 and T2 measurements. We present a new approach using solid echoes in the measurement of T1 and T1-T2 correlations that addresses some of the challenges encountered when making NMR measurements on shale samples compared to conventional reservoir rocks. Combining these techniques with standard T1 and T2 measurements provides a more complete assessment of the hydrogen-bearing constituents (e.g., bitumen, kerogen, clay-bound water) in shale samples. These methods are applied to immature and pyrolyzed oil shale samples to examine the solid and highly viscous organic phases present during the petroleum generation process. The solid echo measurements produce additional signal in the oil shale samples compared to the standard methodologies, indicating the presence of components undergoing homonuclear dipolar coupling. The results presented here include the first low-field NMR measurements performed on kerogen as well as detailed NMR analysis of highly viscous thermally generated bitumen present in pyrolyzed oil shale.

  8. Updated methodology for nuclear magnetic resonance characterization of shales

    USGS Publications Warehouse

    Washburn, Kathryn E.; Birdwell, Justin E.

    2013-01-01

    Unconventional petroleum resources, particularly in shales, are expected to play an increasingly important role in the world’s energy portfolio in the coming years. Nuclear magnetic resonance (NMR), particularly at low-field, provides important information in the evaluation of shale resources. Most of the low-field NMR analyses performed on shale samples rely heavily on standard T1 and T2 measurements. We present a new approach using solid echoes in the measurement of T1 and T1–T2 correlations that addresses some of the challenges encountered when making NMR measurements on shale samples compared to conventional reservoir rocks. Combining these techniques with standard T1 and T2 measurements provides a more complete assessment of the hydrogen-bearing constituents (e.g., bitumen, kerogen, clay-bound water) in shale samples. These methods are applied to immature and pyrolyzed oil shale samples to examine the solid and highly viscous organic phases present during the petroleum generation process. The solid echo measurements produce additional signal in the oil shale samples compared to the standard methodologies, indicating the presence of components undergoing homonuclear dipolar coupling. The results presented here include the first low-field NMR measurements performed on kerogen as well as detailed NMR analysis of highly viscous thermally generated bitumen present in pyrolyzed oil shale.

  9. A portable battery for objective, non-obstrusive measures of human performances

    NASA Technical Reports Server (NTRS)

    Kennedy, R. S.

    1984-01-01

    The need for a standardized battery of human performance tests to measure the effects of various treatments is pointed out. Progress in such a program is reported. Three batteries are available which differ in length and the number of tests in the battery. All tests are implemented on a portable, lap held, briefcase size microprocessor. Performances measured include: information processing, memory, visual perception, reasoning, and motor skills, programs to determine norms, reliabilities, stabilities, factor structure of tests, comparisons with marker tests, apparatus suitability. Rationale for the battery is provided.

  10. Photovoltaic Calibrations at the National Renewable Energy Laboratory and Uncertainty Analysis Following the ISO 17025 Guidelines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Emery, Keith

    The measurement of photovoltaic (PV) performance with respect to reference conditions requires measuring current versus voltage for a given tabular reference spectrum, junction temperature, and total irradiance. This report presents the procedures implemented by the PV Cell and Module Performance Characterization Group at the National Renewable Energy Laboratory (NREL) to achieve the lowest practical uncertainty. A rigorous uncertainty analysis of these procedures is presented, which follows the International Organization for Standardization (ISO) Guide to the Expression of Uncertainty in Measurement. This uncertainty analysis is required for the team’s laboratory accreditation under ISO standard 17025, “General Requirements for the Competence ofmore » Testing and Calibration Laboratories.” The report also discusses additional areas where the uncertainty can be reduced.« less

  11. Systematic review: work-related stress and the HSE management standards.

    PubMed

    Brookes, K; Limbert, C; Deacy, C; O'Reilly, A; Scott, S; Thirlaway, K

    2013-10-01

    The Health and Safety Executive (HSE) has defined six management standards representing aspects of work that, if poorly managed, are associated with lower levels of employee health and productivity, and increased sickness absence. The HSE indicator tool aims to measure organizations' performance in managing the primary stressors identified by the HSE management standards. The aims of the study are to explore how the HSE indicator tool has been implemented within organizations and to identify contexts in which the tool has been used, its psychometric properties and relationships with alternative measures of well-being and stress. Studies that matched specific criteria were included in the review. Abstracts were considered by two researchers to ensure a reliable process. Full texts were obtained when abstracts met the inclusion criteria. Thirteen papers were included in the review. Using factor analysis and measures of reliability, the studies suggest that the HSE indicator tool is a psychometrically sound measure. The tool has been used to measure work-related stress across different occupational groups, with a clear relationship between the HSE tool and alternative measures of well-being. Limitations of the tool and recommendations for future research are discussed. The HSE indicator tool is a psychometrically sound measure of organizational performance against the HSE management standards. As such it can provide a broad overview of sources of work-related stress within organizations. More research is required to explore the use of the tool in the design of interventions to reduce stress, and its use in different contexts and with different cultural and gender groups.

  12. NIST System for Measuring the Directivity Index of Hearing Aids under Simulated Real-Ear Conditions.

    PubMed

    Wagner, Randall P

    2013-01-01

    The directivity index is a parameter that is commonly used to characterize the performance of directional hearing aids, and is determined from the measured directional response. Since this response is different for a hearing aid worn on a person as compared to when it is in a free field, directivity index measurements of hearing aids are usually done under simulated real-ear conditions. Details are provided regarding the NIST system for measuring the hearing aid directivity index under these conditions and how this system is used to implement a standardized procedure for performing such measurements. This procedure involves a sampling method that utilizes sound source locations distributed in a semi-aligned zone array on an imaginary spherical surface surrounding a standardized acoustical test manikin. The capabilities of the system were demonstrated over the frequency range of one-third-octave bands with center frequencies from 200 Hz to 8000 Hz through NIST participation in an interlaboratory comparison. This comparison was conducted between eight different laboratories of members of Working Group S3/WG48, Hearing Aids, established by Accredited Standards Committee S3, Bioacoustics, which is administered by the Acoustical Society of America and accredited by the American National Standards Institute. Directivity measurements were made for a total of six programmed memories in two different hearing aids and for the unaided manikin with the manikin right pinna accompanying the aids. Omnidirectional, cardioid, and bidirectional response patterns were measured. Results are presented comparing the NIST data with the reference values calculated from the data reported by all participating laboratories.

  13. NIST System for Measuring the Directivity Index of Hearing Aids under Simulated Real-Ear Conditions

    PubMed Central

    Wagner, Randall P

    2013-01-01

    The directivity index is a parameter that is commonly used to characterize the performance of directional hearing aids, and is determined from the measured directional response. Since this response is different for a hearing aid worn on a person as compared to when it is in a free field, directivity index measurements of hearing aids are usually done under simulated real-ear conditions. Details are provided regarding the NIST system for measuring the hearing aid directivity index under these conditions and how this system is used to implement a standardized procedure for performing such measurements. This procedure involves a sampling method that utilizes sound source locations distributed in a semi-aligned zone array on an imaginary spherical surface surrounding a standardized acoustical test manikin. The capabilities of the system were demonstrated over the frequency range of one-third-octave bands with center frequencies from 200 Hz to 8000 Hz through NIST participation in an interlaboratory comparison. This comparison was conducted between eight different laboratories of members of Working Group S3/WG48, Hearing Aids, established by Accredited Standards Committee S3, Bioacoustics, which is administered by the Acoustical Society of America and accredited by the American National Standards Institute. Directivity measurements were made for a total of six programmed memories in two different hearing aids and for the unaided manikin with the manikin right pinna accompanying the aids. Omnidirectional, cardioid, and bidirectional response patterns were measured. Results are presented comparing the NIST data with the reference values calculated from the data reported by all participating laboratories. PMID:26401425

  14. An accurate laser radiometer for determining visible exposure times.

    PubMed

    Royston, D D

    1985-01-01

    A laser light radiometer has been developed for the Electro-Optics Branch of the Center for Devices and Radiological Health (CDRH). The radiometer measures direct laser radiation emitted in the visible spectrum. Based upon this measurement, the instrument's microprocessor automatically determines at what time duration the exposure to the measured laser radiation would exceed either the class I accessible emission limits of the Federal Performance Standard for laser products or the maximum permissible exposure limits of laser user safety standards. The instrument also features automatic background level compensation, pulse measurement capability, and self-diagnosis. Measurement of forward surface illumination levels preceding HpD photoradiation therapy is possible.

  15. Design Considerations | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  16. Gas Fills | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  17. Understanding Windows | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  18. Books & Publications | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  19. Efficient Windows Collaborative | Home

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  20. Resources | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  1. Provide Views | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  2. Links | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  3. Reducing Condensation | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  4. Reduced Fading | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  5. EWC Membership | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  6. Visible Transmittance | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  7. EWC Members | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  8. Financing & Incentives | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  9. Community Level Association between Home Health and Nursing Home Performance on Quality and Hospital 30-day Readmissions for Medicare Patients.

    PubMed

    Wang, Yun; Pandolfi, Michelle M; Fine, Jonathan; Metersky, Mark L; Wang, Changqin; Ho, Shih-Yieh; Galusha, Deron; Nuti, Sudhakar V; Murugiah, Karthik; Spenard, Ann; Elwell, Timothy; Krumholz, Harlan M

    2016-11-01

    We evaluated whether community-level home health agencies and nursing home performance is associated with community-level hospital 30-day all-cause risk-standardized readmission rates for Medicare patients used data from the Centers for Medicare & Medicaid Service from 2010 to 2012. Our final sample included 2,855 communities that covered 4,140 hospitals with 6,751,713 patients, 13,060 nursing homes with 1,250,648 residents, and 7,613 home health agencies providing services to 35,660 zipcodes. Based on a mixed effect model, we found that increasing nursing home performance by one star for all of its 4 measures and home health performance by 10 points for all of its 6 measures is associated with decreases of 0.25% (95% CI 0.17-0.34) and 0.60% (95% CI 0.33-0.83), respectively, in community-level risk-standardized readmission rates.

  10. Generation of silver standard concept annotations from biomedical texts with special relevance to phenotypes.

    PubMed

    Oellrich, Anika; Collier, Nigel; Smedley, Damian; Groza, Tudor

    2015-01-01

    Electronic health records and scientific articles possess differing linguistic characteristics that may impact the performance of natural language processing tools developed for one or the other. In this paper, we investigate the performance of four extant concept recognition tools: the clinical Text Analysis and Knowledge Extraction System (cTAKES), the National Center for Biomedical Ontology (NCBO) Annotator, the Biomedical Concept Annotation System (BeCAS) and MetaMap. Each of the four concept recognition systems is applied to four different corpora: the i2b2 corpus of clinical documents, a PubMed corpus of Medline abstracts, a clinical trails corpus and the ShARe/CLEF corpus. In addition, we assess the individual system performances with respect to one gold standard annotation set, available for the ShARe/CLEF corpus. Furthermore, we built a silver standard annotation set from the individual systems' output and assess the quality as well as the contribution of individual systems to the quality of the silver standard. Our results demonstrate that mainly the NCBO annotator and cTAKES contribute to the silver standard corpora (F1-measures in the range of 21% to 74%) and their quality (best F1-measure of 33%), independent from the type of text investigated. While BeCAS and MetaMap can contribute to the precision of silver standard annotations (precision of up to 42%), the F1-measure drops when combined with NCBO Annotator and cTAKES due to a low recall. In conclusion, the performances of individual systems need to be improved independently from the text types, and the leveraging strategies to best take advantage of individual systems' annotations need to be revised. The textual content of the PubMed corpus, accession numbers for the clinical trials corpus, and assigned annotations of the four concept recognition systems as well as the generated silver standard annotation sets are available from http://purl.org/phenotype/resources. The textual content of the ShARe/CLEF (https://sites.google.com/site/shareclefehealth/data) and i2b2 (https://i2b2.org/NLP/DataSets/) corpora needs to be requested with the individual corpus providers.

  11. Determination of photon emission probability for the main gamma ray and half-life measurements of 64Cu.

    PubMed

    Pibida, L; Zimmerman, B; Bergeron, D E; Fitzgerald, R; Cessna, J T; King, L

    2017-11-01

    The National Institute of Standards and Technology (NIST) performed new standardization measurements for 64 Cu. As part of this work the photon emission probability for the main gamma-ray line and the half-life were determined using several high-purity germanium (HPGe) detectors. Half-life determinations were also carried out with a NaI(Tl) well counter and two pressurized ionization chambers. Published by Elsevier Ltd.

  12. Rewards and Supports

    ERIC Educational Resources Information Center

    Hershberg, Theodore; Robertson-Kraft, Claire

    2010-01-01

    Pay-for-performance systems in public schools have long been burdened with controversy. Critics of performance pay systems contend that because teachers' impact cannot be measured without error, it is impossible to create fair and accurate systems for evaluating and rewarding performance. By this standard, however, current practice fails on both…

  13. Identity Affirmed, Agency Engaged: Culturally Responsive Performance-Based Assessment

    ERIC Educational Resources Information Center

    Rosa, Ricardo

    2017-01-01

    Performance-based assessment is unquestionably superior to the instrumental rationality of high-stakes standardized testing and the audit culture that testing regimes inspire. It is more likely to engender opportunities to witness the un-measureable: vision, imagination, and compassion. Performance assessments must be culturally responsive in…

  14. A Review of NIST Primary Activity Standards for (18)F: 1982 to 2013.

    PubMed

    Bergeron, Denis E; Cessna, Jeffrey T; Coursey, Bert M; Fitzgerald, Ryan; Zimmerman, Brian E

    2014-01-01

    The new NIST activity standardization for (18)F, described in 2014 in Applied Radiation and Isotopes (v. 85, p. 77), differs from results obtained between 1998 and 2008 by 4 %. The new results are considered to be very reliable; they are based on a battery of robust primary measurement techniques and bring the NIST standard into accord with other national metrology institutes. This paper reviews all ten (18)F activity standardizations performed at NIST from 1982 to 2013, with a focus on experimental variables that might account for discrepancies. We have identified many possible sources of measurement bias and eliminated most of them, but we have not adequately accounted for the 1998-2008 results.

  15. A Vehicular Mobile Standard Instrument for Field Verification of Traffic Speed Meters Based on Dual-Antenna Doppler Radar Sensor

    PubMed Central

    Du, Lei; Sun, Qiao; Cai, Changqing; Bai, Jie; Fan, Zhe; Zhang, Yue

    2018-01-01

    Traffic speed meters are important legal measuring instruments specially used for traffic speed enforcement and must be tested and verified in the field every year using a vehicular mobile standard speed-measuring instrument to ensure speed-measuring performances. The non-contact optical speed sensor and the GPS speed sensor are the two most common types of standard speed-measuring instruments. The non-contact optical speed sensor requires extremely high installation accuracy, and its speed-measuring error is nonlinear and uncorrectable. The speed-measuring accuracy of the GPS speed sensor is rapidly reduced if the amount of received satellites is insufficient enough, which often occurs in urban high-rise regions, tunnels, and mountainous regions. In this paper, a new standard speed-measuring instrument using a dual-antenna Doppler radar sensor is proposed based on a tradeoff between the installation accuracy requirement and the usage region limitation, which has no specified requirements for its mounting distance and no limitation on usage regions and can automatically compensate for the effect of an inclined installation angle on its speed-measuring accuracy. Theoretical model analysis, simulated speed measurement results, and field experimental results compared with a GPS speed sensor with high accuracy showed that the dual-antenna Doppler radar sensor is effective and reliable as a new standard speed-measuring instrument. PMID:29621142

  16. A Vehicular Mobile Standard Instrument for Field Verification of Traffic Speed Meters Based on Dual-Antenna Doppler Radar Sensor.

    PubMed

    Du, Lei; Sun, Qiao; Cai, Changqing; Bai, Jie; Fan, Zhe; Zhang, Yue

    2018-04-05

    Traffic speed meters are important legal measuring instruments specially used for traffic speed enforcement and must be tested and verified in the field every year using a vehicular mobile standard speed-measuring instrument to ensure speed-measuring performances. The non-contact optical speed sensor and the GPS speed sensor are the two most common types of standard speed-measuring instruments. The non-contact optical speed sensor requires extremely high installation accuracy, and its speed-measuring error is nonlinear and uncorrectable. The speed-measuring accuracy of the GPS speed sensor is rapidly reduced if the amount of received satellites is insufficient enough, which often occurs in urban high-rise regions, tunnels, and mountainous regions. In this paper, a new standard speed-measuring instrument using a dual-antenna Doppler radar sensor is proposed based on a tradeoff between the installation accuracy requirement and the usage region limitation, which has no specified requirements for its mounting distance and no limitation on usage regions and can automatically compensate for the effect of an inclined installation angle on its speed-measuring accuracy. Theoretical model analysis, simulated speed measurement results, and field experimental results compared with a GPS speed sensor with high accuracy showed that the dual-antenna Doppler radar sensor is effective and reliable as a new standard speed-measuring instrument.

  17. CERT Resilience Management Model (CERT-RMM) V1.1: NIST Special Publication Crosswalk Version 1

    DTIC Science & Technology

    2011-11-01

    Organization for Standards ( ISO ) and International Electrotechnical Commission (IEC) 27000 series, COBIT, the British Standards Institution’s BS 25999...and ISO 24762 • includes quantitative process measurements that can be used to ensure operational resilience processes are performing as intended

  18. Patterns and Predictors of Adolescent Academic Achievement and Performance in a Sample of Children with Attention-Deficit/Hyperactivity Disorder

    ERIC Educational Resources Information Center

    Langberg, Joshua M.; Molina, Brooke S. G.; Arnold, L. Eugene; Epstein, Jeffery N.; Altaye, Mekibib; Hinshaw, Stephen P.; Swanson, James M.; Wigal, Timothy; Hechtman, Lily

    2011-01-01

    The current study examined predictors of academic achievement, measured by standardized test scores, and performance, measured by school grades, in adolescents (Mn = 16.8) who met diagnostic criteria for Attention-Deficit/Hyperactivity Disorder (ADHD)-Combined type in early childhood (Mn age = 8.5; N = 579). Several mediation models were also…

  19. Development of a low-level 39Ar calibration standard – Analysis by absolute gas counting measurements augmented with simulation

    DOE PAGES

    Williams, Richard M.; Aalseth, C. E.; Brandenberger, J. M.; ...

    2017-02-17

    Here, this paper describes the generation of 39Ar, via reactor irradiation of potassium carbonate, followed by quantitative analysis (length-compensated proportional counting) to yield two calibration standards that are respectively 50 and 3 times atmospheric background levels. Measurements were performed in Pacific Northwest National Laboratory's shallow underground counting laboratory studying the effect of gas density on beta-transport; these results are compared with simulation. The total expanded uncertainty of the specific activity for the ~50 × 39Ar in P10 standard is 3.6% (k=2).

  20. Development of a low-level 39Ar calibration standard – Analysis by absolute gas counting measurements augmented with simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, Richard M.; Aalseth, C. E.; Brandenberger, J. M.

    Here, this paper describes the generation of 39Ar, via reactor irradiation of potassium carbonate, followed by quantitative analysis (length-compensated proportional counting) to yield two calibration standards that are respectively 50 and 3 times atmospheric background levels. Measurements were performed in Pacific Northwest National Laboratory's shallow underground counting laboratory studying the effect of gas density on beta-transport; these results are compared with simulation. The total expanded uncertainty of the specific activity for the ~50 × 39Ar in P10 standard is 3.6% (k=2).

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bamberger, Judith A.; Piepel, Gregory F.; Enderlin, Carl W.

    Understanding how uncertainty manifests itself in complex experiments is important for developing the testing protocol and interpreting the experimental results. This paper describes experimental and measurement uncertainties, and how they can depend on the order of performing experimental tests. Experiments with pulse-jet mixers in tanks at three scales were conducted to characterize the performance of transient-developing periodic flows in Newtonian slurries. Other test parameters included the simulant, solids concentration, and nozzle exit velocity. Critical suspension velocity and cloud height were the metrics used to characterize Newtonian slurry flow associated with mobilization and mixing. During testing, near-replicate and near-repeat tests weremore » conducted. The experimental results were used to quantify the combined experimental and measurement uncertainties using standard deviations and percent relative standard deviations (%RSD) The uncertainties in critical suspension velocity and cloud height tend to increase with the values of these responses. Hence, the %RSD values are the more appropriate summary measure of near-replicate testing and measurement uncertainty.« less

  2. Inflight evaluation of pilot workload measures for rotorcraft research

    NASA Technical Reports Server (NTRS)

    Shively, Robert J.; Bortolussi, Michael R.; Battiste, Vernol; Hart, Sandra G.; Pepitone, David D.; Matsumoto, Joy Hamerman

    1987-01-01

    The effectiveness of heart-rate monitoring and the NASA TLX workload rating scale (Hart et al., 1985) in measuring helicopter-pilot workloads is investigated experimentally. Four NASA test pilots flew two 2-h missions each in an SH-3G helicopter, following scenarios with takeoff, hover, cross-country, and landing tasks; pilot performance on the tasks undertaken near the landing area was measured by laser tracking. The results are presented in graphs and discussed in detail, and it is found that the TLX ratings clearly distinguish the flight segments and are well correlated with the performance data. The mean heart rate (measured as interbeat interval) is correlated (r = -0.69) with the TLX workload, but only the standard deviation of the interbeat interval is able to distinguish between flight segments; the correlation between standard deviation and TLX ratings is negative but not significant.

  3. Performance and System Validation of a New Cellular-Enabled Blood Glucose Monitoring System Using a New Standard Reference Measurement Procedure of Isotope Dilution UPLC-MRM Mass Spectrometry

    PubMed Central

    Angelides, Kimon; Matsunami, Risë K.; Engler, David A.

    2015-01-01

    Background: We evaluated the accuracy, precision, and linearity of the In Touch® blood glucose monitoring system (BGMS), a new color touch screen and cellular-enabled blood glucose meter, using a new rapid, highly precise and accurate 13C6 isotope-dilution liquid chromatography-mass spectrometry method (IDLC-MS). Methods: Blood glucose measurements from the In Touch® BGMS were referenced to a validated UPLC-MRM standard reference measurement procedure previously shown to be highly accurate and precise. Readings from the In Touch® BGMS were taken over the blood glucose range of 24-640 mg/dL using 12 concentrations of blood glucose. Ten In Touch® BGMS and 3 lots of test strips were used with 10 replicates at each concentration. A lay user study was also performed to assess the ease of use. Results: At blood glucose concentrations <75 mg/dL 100% of the measurements are within ±8 mg/dL from the true reference standard; at blood glucose levels >75 mg/dL 100% of the measurements are within ±15% of the true reference standard. 100% of the results are within category A of the consensus grid. Within-run precision show CV < 3.72% between 24-50 mg/dL and CV<2.22% between 500 and 600 mg/dL. The results show that the In Touch® meter exceeds the minimum criteria of both the ISO 15197:2003 and ISO 15197:2013 standards. The results from a user panel show that 100% of the respondents reported that the color touch screen, with its graphic user interface (GUI), is well labeled and easy to navigate. Conclusions: To our knowledge this is the first touch screen glucose meter and the first study where accuracy of a new BGMS has been measured against a true primary reference standard, namely IDLC-MS. PMID:26002836

  4. Energy savings and cost-benefit analysis of the new commercial building standard in China

    DOE PAGES

    Zhao, Shanguo; Feng, Wei; Zhang, Shicong; ...

    2015-10-07

    In this study, a comprehensive comparison of the commercial building energy efficiency standard between the previous 2005 version and the new proposed version is conducted, including the energy efficiency analysis and cost-benefit analysis. To better understand the tech-economic performance of the new Chinese standard, energy models were set up based on a typical commercial office building in Chinese climate zones. The building energy standard in 2005 is used as the baseline for this analysis. Key building technologies measures are analyzed individually, including roof, wall, window, lighting and chiller and so on and finally whole building cost-benefit analysis was conducted. Resultsmore » show that the new commercial building energy standard demonstrates good cost-effective performance, with whole building payback period around 4 years.« less

  5. Energy savings and cost-benefit analysis of the new commercial building standard in China

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Shanguo; Feng, Wei; Zhang, Shicong

    In this study, a comprehensive comparison of the commercial building energy efficiency standard between the previous 2005 version and the new proposed version is conducted, including the energy efficiency analysis and cost-benefit analysis. To better understand the tech-economic performance of the new Chinese standard, energy models were set up based on a typical commercial office building in Chinese climate zones. The building energy standard in 2005 is used as the baseline for this analysis. Key building technologies measures are analyzed individually, including roof, wall, window, lighting and chiller and so on and finally whole building cost-benefit analysis was conducted. Resultsmore » show that the new commercial building energy standard demonstrates good cost-effective performance, with whole building payback period around 4 years.« less

  6. Precise measurement of the {sup 19}Ne half-life

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Triambak, S.; TRIUMF, 4004 Wesbrook Mall, Vancouver, BC V6T 2A3

    2011-11-30

    We describe a high-precision measurement of the half-life of the T = 1/2 nucleus {sup 19}Ne, performed at TRIUMF, Canada's National Laboratory for Nuclear and Particle Physics, Vancouver, Canada. Some implications of this measurement related to tests of the Standard Model are discussed.

  7. Using Clinical Data Standards to Measure Quality: A New Approach.

    PubMed

    D'Amore, John D; Li, Chun; McCrary, Laura; Niloff, Jonathan M; Sittig, Dean F; McCoy, Allison B; Wright, Adam

    2018-04-01

     Value-based payment for care requires the consistent, objective calculation of care quality. Previous initiatives to calculate ambulatory quality measures have relied on billing data or individual electronic health records (EHRs) to calculate and report performance. New methods for quality measure calculation promoted by federal regulations allow qualified clinical data registries to report quality outcomes based on data aggregated across facilities and EHRs using interoperability standards.  This research evaluates the use of clinical document interchange standards as the basis for quality measurement.  Using data on 1,100 patients from 11 ambulatory care facilities and 5 different EHRs, challenges to quality measurement are identified and addressed for 17 certified quality measures.  Iterative solutions were identified for 14 measures that improved patient inclusion and measure calculation accuracy. Findings validate this approach to improving measure accuracy while maintaining measure certification.  Organizations that report care quality should be aware of how identified issues affect quality measure selection and calculation. Quality measure authors should consider increasing real-world validation and the consistency of measure logic in respect to issues identified in this research. Schattauer GmbH Stuttgart.

  8. 14 CFR Appendix C to Part 91 - Operations in the North Atlantic (NAT) Minimum Navigation Performance Specifications (MNPS) Airspace

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... defined in section 1 of this appendix is as follows: (a) The standard deviation of lateral track errors shall be less than 6.3 NM (11.7 Km). Standard deviation is a statistical measure of data about a mean... standard deviation about the mean encompasses approximately 68 percent of the data and plus or minus 2...

  9. Objective Assessment of Spectral Ripple Discrimination in Cochlear Implant Listeners Using Cortical Evoked Responses to an Oddball Paradigm

    PubMed Central

    Lopez Valdes, Alejandro; Mc Laughlin, Myles; Viani, Laura; Walshe, Peter; Smith, Jaclyn; Zeng, Fan-Gang; Reilly, Richard B.

    2014-01-01

    Cochlear implants (CIs) can partially restore functional hearing in deaf individuals. However, multiple factors affect CI listener's speech perception, resulting in large performance differences. Non-speech based tests, such as spectral ripple discrimination, measure acoustic processing capabilities that are highly correlated with speech perception. Currently spectral ripple discrimination is measured using standard psychoacoustic methods, which require attentive listening and active response that can be difficult or even impossible in special patient populations. Here, a completely objective cortical evoked potential based method is developed and validated to assess spectral ripple discrimination in CI listeners. In 19 CI listeners, using an oddball paradigm, cortical evoked potential responses to standard and inverted spectrally rippled stimuli were measured. In the same subjects, psychoacoustic spectral ripple discrimination thresholds were also measured. A neural discrimination threshold was determined by systematically increasing the number of ripples per octave and determining the point at which there was no longer a significant difference between the evoked potential response to the standard and inverted stimuli. A correlation was found between the neural and the psychoacoustic discrimination thresholds (R2 = 0.60, p<0.01). This method can objectively assess CI spectral resolution performance, providing a potential tool for the evaluation and follow-up of CI listeners who have difficulty performing psychoacoustic tests, such as pediatric or new users. PMID:24599314

  10. Objective assessment of spectral ripple discrimination in cochlear implant listeners using cortical evoked responses to an oddball paradigm.

    PubMed

    Lopez Valdes, Alejandro; Mc Laughlin, Myles; Viani, Laura; Walshe, Peter; Smith, Jaclyn; Zeng, Fan-Gang; Reilly, Richard B

    2014-01-01

    Cochlear implants (CIs) can partially restore functional hearing in deaf individuals. However, multiple factors affect CI listener's speech perception, resulting in large performance differences. Non-speech based tests, such as spectral ripple discrimination, measure acoustic processing capabilities that are highly correlated with speech perception. Currently spectral ripple discrimination is measured using standard psychoacoustic methods, which require attentive listening and active response that can be difficult or even impossible in special patient populations. Here, a completely objective cortical evoked potential based method is developed and validated to assess spectral ripple discrimination in CI listeners. In 19 CI listeners, using an oddball paradigm, cortical evoked potential responses to standard and inverted spectrally rippled stimuli were measured. In the same subjects, psychoacoustic spectral ripple discrimination thresholds were also measured. A neural discrimination threshold was determined by systematically increasing the number of ripples per octave and determining the point at which there was no longer a significant difference between the evoked potential response to the standard and inverted stimuli. A correlation was found between the neural and the psychoacoustic discrimination thresholds (R2=0.60, p<0.01). This method can objectively assess CI spectral resolution performance, providing a potential tool for the evaluation and follow-up of CI listeners who have difficulty performing psychoacoustic tests, such as pediatric or new users.

  11. Titration Calorimetry Standards and the Precision of Isothermal Titration Calorimetry Data

    PubMed Central

    Baranauskienė, Lina; Petrikaitė, Vilma; Matulienė, Jurgita; Matulis, Daumantas

    2009-01-01

    Current Isothermal Titration Calorimetry (ITC) data in the literature have relatively high errors in the measured enthalpies of protein-ligand binding reactions. There is a need for universal validation standards for titration calorimeters. Several inorganic salt co-precipitation and buffer protonation reactions have been suggested as possible enthalpy standards. The performances of several commercial calorimeters, including the VP-ITC, ITC200, and Nano ITC-III, were validated using these suggested standard reactions. PMID:19582227

  12. Performances of OsO(4) stabilized CO(2) lasers as optical frequency standards near 29 THz.

    PubMed

    Daussy, C; Ducos, F; Rovera, G D; Acef, O

    2000-01-01

    In this paper, we report on the metrological capabilities of CO (2)/OsO(4) optical frequency standards operating around 29 THz. Those frequency standards are currently involved in various fields, such as frequency metrology, high resolution spectroscopy, and Rydberg constant measurements. The most impressive features of the standards lies in the 10(-15) level frequency stability allied to a long-term reproducibility (1 yr) of 1.3x10 (-13).

  13. The Mediating Relation between Symbolic and Nonsymbolic Foundations of Math Competence

    PubMed Central

    Price, Gavin R.; Fuchs, Lynn S.

    2016-01-01

    This study investigated the relation between symbolic and nonsymbolic magnitude processing abilities with 2 standardized measures of math competence (WRAT Arithmetic and KeyMath Numeration) in 150 3rd- grade children (mean age 9.01 years). Participants compared sets of dots and pairs of Arabic digits with numerosities 1–9 for relative numerical magnitude. In line with previous studies, performance on both symbolic and nonsymbolic magnitude processing was related to math ability. Performance metrics combining reaction and accuracy, as well as weber fractions, were entered into mediation models with standardized math test scores. Results showed that symbolic magnitude processing ability fully mediates the relation between nonsymbolic magnitude processing and math ability, regardless of the performance metric or standardized test. PMID:26859564

  14. The Mediating Relation between Symbolic and Nonsymbolic Foundations of Math Competence.

    PubMed

    Price, Gavin R; Fuchs, Lynn S

    2016-01-01

    This study investigated the relation between symbolic and nonsymbolic magnitude processing abilities with 2 standardized measures of math competence (WRAT Arithmetic and KeyMath Numeration) in 150 3rd-grade children (mean age 9.01 years). Participants compared sets of dots and pairs of Arabic digits with numerosities 1-9 for relative numerical magnitude. In line with previous studies, performance on both symbolic and nonsymbolic magnitude processing was related to math ability. Performance metrics combining reaction and accuracy, as well as weber fractions, were entered into mediation models with standardized math test scores. Results showed that symbolic magnitude processing ability fully mediates the relation between nonsymbolic magnitude processing and math ability, regardless of the performance metric or standardized test.

  15. Benefits of Efficient Windows | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  16. Increased Light & View | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  17. Windows for New Construction | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  18. Window Selection Tool | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  19. Air Leakage (AL) | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  20. State Fact Sheets | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  1. Fact Sheets & Publications | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  2. Condensation Resistance (CR) | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  3. Assessing Window Replacement Options | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  4. Low Conductance Spacers | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  5. Energy & Cost Savings | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  6. U-Factor (U-value) | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  7. Procedures for Constructing and Using Criterion-Referenced Performance Tests.

    ERIC Educational Resources Information Center

    Campbell, Clifton P.; Allender, Bill R.

    1988-01-01

    Criterion-referenced performance tests (CRPT) provide a realistic method for objectively measuring task proficiency against predetermined attainment standards. This article explains the procedures of constructing, validating, and scoring CRPTs and includes a checklist for a welding test. (JOW)

  8. Validity of clinical outcome measures to evaluate ankle range of motion during the weight-bearing lunge test.

    PubMed

    Hall, Emily A; Docherty, Carrie L

    2017-07-01

    To determine the concurrent validity of standard clinical outcome measures compared to laboratory outcome measure while performing the weight-bearing lunge test (WBLT). Cross-sectional study. Fifty participants performed the WBLT to determine dorsiflexion ROM using four different measurement techniques: dorsiflexion angle with digital inclinometer at 15cm distal to the tibial tuberosity (°), dorsiflexion angle with inclinometer at tibial tuberosity (°), maximum lunge distance (cm), and dorsiflexion angle using a 2D motion capture system (°). Outcome measures were recorded concurrently during each trial. To establish concurrent validity, Pearson product-moment correlation coefficients (r) were conducted, comparing each dependent variable to the 2D motion capture analysis (identified as the reference standard). A higher correlation indicates strong concurrent validity. There was a high correlation between each measurement technique and the reference standard. Specifically the correlation between the inclinometer placement at 15cm below the tibial tuberosity (44.9°±5.5°) and the motion capture angle (27.0°±6.0°) was r=0.76 (p=0.001), between the inclinometer placement at the tibial tuberosity angle (39.0°±4.6°) and the motion capture angle was r=0.71 (p=0.001), and between the distance from the wall clinical measure (10.3±3.0cm) to the motion capture angle was r=0.74 (p=0.001). This study determined that the clinical measures used during the WBLT have a high correlation with the reference standard for assessing dorsiflexion range of motion. Therefore, obtaining maximum lunge distance and inclinometer angles are both valid assessments during the weight-bearing lunge test. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  9. 45 CFR 305.32 - Requirements applicable to calculations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... HUMAN SERVICES PROGRAM PERFORMANCE MEASURES, STANDARDS, FINANCIAL INCENTIVES, AND PENALTIES § 305.32... necessary to calculate performance for incentives and penalties for a fiscal year must be submitted to the... fiscal year. Only data submitted as of December 31st will be used to determine the State's performance...

  10. 45 CFR 305.42 - Penalty phase-in.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... PROGRAM PERFORMANCE MEASURES, STANDARDS, FINANCIAL INCENTIVES, AND PENALTIES § 305.42 Penalty phase-in. States are subject to the performance penalties described in § 305.40 based on data reported for FY 2001. Data reported for FY 2000 will be used as a base year to determine improvements in performance during...

  11. Positive Workplace Dynamics: A Qualitative Exploration of Exceptional Performance in Community College Units

    ERIC Educational Resources Information Center

    Stapleton, R. Michael

    2013-01-01

    This companion dissertation reports the findings of applied case study research on four community college organizational units that consistently meet or exceed standard performance measures. In addition, prior ample evidence confirmed that performance extended significantly beyond what might be explained by available tangible resources alone. The…

  12. 42 CFR 416.43 - Conditions for coverage-Quality assessment and performance improvement.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... outcomes, patient safety, and quality of care. (2) Performance improvement activities must track adverse... patient safety by using quality indicators or performance measures associated with improved health... that includes care and services furnished in the ASC. (b) Standard: Program data. (1) The program must...

  13. Cryogenic insulation standard data and methodologies

    NASA Astrophysics Data System (ADS)

    Demko, J. A.; Fesmire, J. E.; Johnson, W. L.; Swanger, A. M.

    2014-01-01

    Although some standards exist for thermal insulation, few address the sub-ambient temperature range and cold-side temperatures below 100 K. Standards for cryogenic insulation systems require cryostat testing and data analysis that will allow the development of the tools needed by design engineers and thermal analysts for the design of practical cryogenic systems. Thus, this critically important information can provide reliable data and methodologies for industrial efficiency and energy conservation. Two Task Groups have been established in the area of cryogenic insulation systems Under ASTM International's Committee C16 on Thermal Insulation. These are WK29609 - New Standard for Thermal Performance Testing of Cryogenic Insulation Systems and WK29608 - Standard Practice for Multilayer Insulation in Cryogenic Service. The Cryogenics Test Laboratory of NASA Kennedy Space Center and the Thermal Energy Laboratory of LeTourneau University are conducting Inter-Laboratory Study (ILS) of selected insulation materials. Each lab carries out the measurements of thermal properties of these materials using identical flat-plate boil-off calorimeter instruments. Parallel testing will provide the comparisons necessary to validate the measurements and methodologies. Here we discuss test methods, some initial data in relation to the experimental approach, and the manner reporting the thermal performance data. This initial study of insulation materials for sub-ambient temperature applications is aimed at paving the way for further ILS comparative efforts that will produce standard data sets for several commercial materials. Discrepancies found between measurements will be used to improve the testing and data reduction techniques being developed as part of the future ASTM International standards.

  14. Safety in numbers: the development of Leapfrog's composite patient safety score for U.S. hospitals.

    PubMed

    Austin, J Matthew; D'Andrea, Guy; Birkmeyer, John D; Leape, Lucian L; Milstein, Arnold; Pronovost, Peter J; Romano, Patrick S; Singer, Sara J; Vogus, Timothy J; Wachter, Robert M

    2014-03-01

    To develop a composite patient safety score that provides patients, health-care providers, and health-care purchasers with a standardized method to evaluate patient safety in general acute care hospitals in the United States. The Leapfrog Group sought guidance from a panel of national patient safety experts to develop the composite score. Candidate patient safety performance measures for inclusion in the score were identified from publicly reported national sources. Hospital performance on each measure was converted into a "z-score" and then aggregated using measure-specific weights. A reference mean score was set at 3, with scores interpreted in terms of standard deviations above or below the mean, with above reflecting better than average performance. Twenty-six measures were included in the score. The mean composite score for 2652 general acute care hospitals in the United States was 2.97 (range by hospital, 0.46-3.94). Safety scores were slightly lower for hospitals that were publicly owned, rural in location, or had a larger percentage of patients with Medicaid as their primary insurance. The Leapfrog patient safety composite provides a standardized method to evaluate patient safety in general acute care hospitals in the United States. While constrained by available data and publicly reported scores on patient safety measures, the composite score reflects the best available evidence regarding a hospital's efforts and outcomes in patient safety. Additional analyses are needed, but the score did not seem to have a strong bias against hospitals with specific characteristics. The composite score will continue to be refined over time as measures of patient safety evolve.

  15. The dysfunctional consequences of a performance measurement system: the case of the Iranian national hospital grading programme.

    PubMed

    Aryankhesal, Aidin; Sheldon, Trevor A; Mannion, Russell; Mahdipour, Saeade

    2015-07-01

    Performance measurement systems are increasingly used to reward and improve provider performance. However, such initiatives may also inadvertently induce a range of unintended and dysfunctional side-effects. This study explores the unintended and adverse consequences induced by the Iranian national hospital grading programme, which incorporates financial incentives for meeting nationally defined standards. We interviewed key informants across four key groups with a legitimate interest in healthcare performance: four purposively selected hospitals; four health insurance organizations; the Iranian hospital accreditation body; and one grading agency. The transcribed interviews and field notes were analysed thematically, and subsequently, member checking was conducted. Seven dysfunctional consequences were identified: misrepresentation of data by hospitals; increased anxiety and stress among hospital employees; tunnel vision; financial pressures on poorly graded hospitals; incentives to purchase unnecessary equipment; erosion of public trust; and restricting access to hospital services by patients. These were caused by the way the grading system was implemented: poor standards of audit; the way in which the audit process was conducted; and the timing of audits. The pay for performance element of the grading system and the focus on structural aspects in the standards made improvement in grading particularly difficult for those hospitals that had been assessed as under-performing. Although the Iranian hospital grading system has resulted in a significant increase in the adoption of national standards, it has nevertheless induced a range of perverse outcomes. To mitigate these requires further refinement and recalibration of the system. © The Author(s) 2015.

  16. A randomized, controlled trial of in situ pediatric advanced life support recertification ("pediatric advanced life support reconstructed") compared with standard pediatric advanced life support recertification for ICU frontline providers*.

    PubMed

    Kurosawa, Hiroshi; Ikeyama, Takanari; Achuff, Patricia; Perkel, Madeline; Watson, Christine; Monachino, Annemarie; Remy, Daphne; Deutsch, Ellen; Buchanan, Newton; Anderson, Jodee; Berg, Robert A; Nadkarni, Vinay M; Nishisaki, Akira

    2014-03-01

    Recent evidence shows poor retention of Pediatric Advanced Life Support provider skills. Frequent refresher training and in situ simulation are promising interventions. We developed a "Pediatric Advanced Life Support-reconstructed" recertification course by deconstructing the training into six 30-minute in situ simulation scenario sessions delivered over 6 months. We hypothesized that in situ Pediatric Advanced Life Support-reconstructed implementation is feasible and as effective as standard Pediatric Advanced Life Support recertification. A prospective randomized, single-blinded trial. Single-center, large, tertiary PICU in a university-affiliated children's hospital. Nurses and respiratory therapists in PICU. Simulation-based modular Pediatric Advanced Life Support recertification training. Simulation-based pre- and postassessment sessions were conducted to evaluate participants' performance. Video-recorded sessions were rated by trained raters blinded to allocation. The primary outcome was skill performance measured by a validated Clinical Performance Tool, and secondary outcome was behavioral performance measured by a Behavioral Assessment Tool. A mixed-effect model was used to account for baseline differences. Forty participants were prospectively randomized to Pediatric Advanced Life Support reconstructed versus standard Pediatric Advanced Life Support with no significant difference in demographics. Clinical Performance Tool score was similar at baseline in both groups and improved after Pediatric Advanced Life Support reconstructed (pre, 16.3 ± 4.1 vs post, 22.4 ± 3.9; p < 0.001), but not after standard Pediatric Advanced Life Support (pre, 14.3 ± 4.7 vs post, 14.9 ± 4.4; p =0.59). Improvement of Clinical Performance Tool was significantly higher in Pediatric Advanced Life Support reconstructed compared with standard Pediatric Advanced Life Support (p = 0.006). Behavioral Assessment Tool improved in both groups: Pediatric Advanced Life Support reconstructed (pre, 33.3 ± 4.5 vs post, 35.9 ± 5.0; p = 0.008) and standard Pediatric Advanced Life Support (pre, 30.5 ± 4.7 vs post, 33.6 ± 4.9; p = 0.02), with no significant difference of improvement between both groups (p = 0.49). For PICU-based nurses and respiratory therapists, simulation-based "Pediatric Advanced Life Support-reconstructed" in situ training is feasible and more effective than standard Pediatric Advanced Life Support recertification training for skill performance. Both Pediatric Advanced Life Support recertification training courses improved behavioral performance.

  17. Functional assessment and performance evaluation for assistive robotic manipulators: Literature review

    PubMed Central

    Chung, Cheng-Shiu; Wang, Hongwu; Cooper, Rory A.

    2013-01-01

    Context The user interface development of assistive robotic manipulators can be traced back to the 1960s. Studies include kinematic designs, cost-efficiency, user experience involvements, and performance evaluation. This paper is to review studies conducted with clinical trials using activities of daily living (ADLs) tasks to evaluate performance categorized using the International Classification of Functioning, Disability, and Health (ICF) frameworks, in order to give the scope of current research and provide suggestions for future studies. Methods We conducted a literature search of assistive robotic manipulators from 1970 to 2012 in PubMed, Google Scholar, and University of Pittsburgh Library System – PITTCat. Results Twenty relevant studies were identified. Conclusion Studies were separated into two broad categories: user task preferences and user-interface performance measurements of commercialized and developing assistive robotic manipulators. The outcome measures and ICF codes associated with the performance evaluations are reported. Suggestions for the future studies include (1) standardized ADL tasks for the quantitative and qualitative evaluation of task efficiency and performance to build comparable measures between research groups, (2) studies relevant to the tasks from user priority lists and ICF codes, and (3) appropriate clinical functional assessment tests with consideration of constraints in assistive robotic manipulator user interfaces. In addition, these outcome measures will help physicians and therapists build standardized tools while prescribing and assessing assistive robotic manipulators. PMID:23820143

  18. Analytical and Experimental Performance Evaluation of BLE Neighbor Discovery Process Including Non-Idealities of Real Chipsets

    PubMed Central

    Perez-Diaz de Cerio, David; Hernández, Ángela; Valenzuela, Jose Luis; Valdovinos, Antonio

    2017-01-01

    The purpose of this paper is to evaluate from a real perspective the performance of Bluetooth Low Energy (BLE) as a technology that enables fast and reliable discovery of a large number of users/devices in a short period of time. The BLE standard specifies a wide range of configurable parameter values that determine the discovery process and need to be set according to the particular application requirements. Many previous works have been addressed to investigate the discovery process through analytical and simulation models, according to the ideal specification of the standard. However, measurements show that additional scanning gaps appear in the scanning process, which reduce the discovery capabilities. These gaps have been identified in all of the analyzed devices and respond to both regular patterns and variable events associated with the decoding process. We have demonstrated that these non-idealities, which are not taken into account in other studies, have a severe impact on the discovery process performance. Extensive performance evaluation for a varying number of devices and feasible parameter combinations has been done by comparing simulations and experimental measurements. This work also includes a simple mathematical model that closely matches both the standard implementation and the different chipset peculiarities for any possible parameter value specified in the standard and for any number of simultaneous advertising devices under scanner coverage. PMID:28273801

  19. High IQ May "Mask" the Diagnosis of ADHD by Compensating for Deficits in Executive Functions in Treatment-Naïve Adults With ADHD.

    PubMed

    Milioni, Ana Luiza Vidal; Chaim, Tiffany Moukbel; Cavallet, Mikael; de Oliveira, Nathalya Moleda; Annes, Marco; Dos Santos, Bernardo; Louzã, Mario; da Silva, Maria Aparecida; Miguel, Carmen Silvia; Serpa, Mauricio Henriques; Zanetti, Marcus V; Busatto, Geraldo; Cunha, Paulo Jannuzzi

    2017-04-01

    To evaluate and compare the performance of adults with ADHD with high and standard IQ in executive functions (EF) tasks. We investigated the neuropsychological performance of 51 adults with ADHD, compared with 33 healthy controls (HC) while performing a wide battery of neuropsychological tests that measure executive functioning. Adults with clinical diagnosis of ADHD were divided into two groups according to their IQ level (IQ ≥ 110-ADHD group with more elevated IQ, and IQ < 110-ADHD group with standard IQ). The ADHD group with standard IQ presented a worse executive functioning compared with the HC group in the following measures: Stroop 2 ( p = .000) and 3 ( p = .000), Trail Making Test (TMT) B ( p = .005), Wisconsin Card-Sorting Test (WCST)-perseverative errors ( p = .022) and failures to maintain set ( p = .020), Continuous Performance Test (CPT)-omission errors ( p = .005) and commission errors ( p = .000), and Frontal Assessment Battery (FAB)-conceptualization ( p = .016). The ADHD group with more elevated IQ presented only impairments in the CPT-commission errors ( p = .019) when compared with the control group. Adults with ADHD and more elevated IQ show less evidence of executive functioning deficits compared with those with ADHD and standard IQ, suggesting that a higher degree of intellectual efficiency may compensate deficits in executive functions, leading to problems in establishing a precise clinical diagnosis.

  20. Analytical and Experimental Performance Evaluation of BLE Neighbor Discovery Process Including Non-Idealities of Real Chipsets.

    PubMed

    Perez-Diaz de Cerio, David; Hernández, Ángela; Valenzuela, Jose Luis; Valdovinos, Antonio

    2017-03-03

    The purpose of this paper is to evaluate from a real perspective the performance of Bluetooth Low Energy (BLE) as a technology that enables fast and reliable discovery of a large number of users/devices in a short period of time. The BLE standard specifies a wide range of configurable parameter values that determine the discovery process and need to be set according to the particular application requirements. Many previous works have been addressed to investigate the discovery process through analytical and simulation models, according to the ideal specification of the standard. However, measurements show that additional scanning gaps appear in the scanning process, which reduce the discovery capabilities. These gaps have been identified in all of the analyzed devices and respond to both regular patterns and variable events associated with the decoding process. We have demonstrated that these non-idealities, which are not taken into account in other studies, have a severe impact on the discovery process performance. Extensive performance evaluation for a varying number of devices and feasible parameter combinations has been done by comparing simulations and experimental measurements. This work also includes a simple mathematical model that closely matches both the standard implementation and the different chipset peculiarities for any possible parameter value specified in the standard and for any number of simultaneous advertising devices under scanner coverage.

  1. The Relationship between Students' Performance on Conventional Standardized Mathematics Assessments and Complex Mathematical Modeling Problems

    ERIC Educational Resources Information Center

    Kartal, Ozgul; Dunya, Beyza Aksu; Diefes-Dux, Heidi A.; Zawojewski, Judith S.

    2016-01-01

    Critical to many science, technology, engineering, and mathematics (STEM) career paths is mathematical modeling--specifically, the creation and adaptation of mathematical models to solve problems in complex settings. Conventional standardized measures of mathematics achievement are not structured to directly assess this type of mathematical…

  2. 12 CFR Appendix B to Part 1720 - Policy Guidance; Non-Mortgage Liquidity Investments

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... control standards; v. The limits structure; vi. The performance standards and measures; and vii. The... risk oversight group. f. The Enterprise should adopt a limit structure to promote diversification in..., management should consider the discrete risks associated with the non-mortgage liquidity investment portfolio...

  3. 12 CFR Appendix B to Part 1720 - Policy Guidance; Non-Mortgage Liquidity Investments

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... control standards; v. The limits structure; vi. The performance standards and measures; and vii. The... risk oversight group. f. The Enterprise should adopt a limit structure to promote diversification in..., management should consider the discrete risks associated with the non-mortgage liquidity investment portfolio...

  4. 12 CFR Appendix B to Part 1720 - Policy Guidance; Non-Mortgage Liquidity Investments

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... control standards; v. The limits structure; vi. The performance standards and measures; and vii. The... risk oversight group. f. The Enterprise should adopt a limit structure to promote diversification in..., management should consider the discrete risks associated with the non-mortgage liquidity investment portfolio...

  5. 12 CFR Appendix B to Part 1720 - Policy Guidance; Non-Mortgage Liquidity Investments

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... control standards; v. The limits structure; vi. The performance standards and measures; and vii. The... risk oversight group. f. The Enterprise should adopt a limit structure to promote diversification in..., management should consider the discrete risks associated with the non-mortgage liquidity investment portfolio...

  6. End-Use Load and Conservation Assessment Program : Co-Instrumentation Test of Two Microcomputer-Based Energy Monitoring Systems.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fishbaugher, M. J.

    1985-05-01

    The decreasing cost of microcomputers along with improvements in power metering circuitry have changed the way in which electrical energy use is monitored. Although utilities still rely on kilowatt-hour (kWh) meters for billing purposes, a microcomputer-based monitoring system is used when greater temporal and end-use resolution is desired. Because these types of monitoring systems will be used increasingly in large-scale conservation and end-use studies, it is important that their performance be analyzed to determine their accuracy. A co-instrumentation test was devised in which two such microcomputer-based monitoring systems made simultaneous measurements of electrical end-uses in two commercial buildings. The analysismore » of the co-instrumentation data aids in the evaluation of microcomputer-based monitoring systems used for end-use measurements. Separate and independent data loggers were used to measure the same loads simultaneously. In addition to these two systems, a utility billing meter measured the total energy use in each building during the co-instrumentation test. The utility's meters provided a relatively accurate standard by which the performance of both loggers could be judged. The comparison between the SCL and PNL microcomputer-based loggers has shown that power measurement techniques directly affect system performance. The co-instrumentation test has shown that there are certain standards that a monitoring system must meet if it is to perform well. First, it is essential to calibrate a microcomputer-based logger against a known standard load before the system is installed. Second, a microcomputer-based system must have some way of accounting for power factors. Recent advances in power metering circuitry have made it relatively easy to apply these power factors automatically in real time.« less

  7. Self-regulated learning and achievement by middle-school children.

    PubMed

    Sink, C A; Barnett, J E; Hixon, J E

    1991-12-01

    The relationship of self-regulated learning to the achievement test scores of 62 Grade 6 students was studied. Generally, the metacognitive and affective variables correlated significantly with teachers' grades and standardized test scores in mathematics, reading, and science. Planning and self-assessment significantly predicted the six measures of achievement. Step-wise multiple regression analyses using the metacognitive and affective variables largely indicate that students' and teachers' perceptions of scholastic ability and planning appear to be the most salient factors in predicting academic performance. The locus of control dimension had no utility in predicting classroom grades and performance on standardized measures of achievement. The implications of the findings for teaching and learning are discussed.

  8. Relative efficiency calibration between two silicon drift detectors performed with a monochromatized X-ray generator over the 0.1-1.5 keV range

    NASA Astrophysics Data System (ADS)

    Hubert, S.; Boubault, F.

    2018-03-01

    In this article, we present the first X-ray calibration performed over the 0.1-1.5 keV spectral range by means of a soft X-ray Manson source and the monochromator SYMPAX. This monochromator, based on a classical Rowland geometry, presents the novelty to be able to board simultaneously two detectors and move them under vacuum in front of the exit slit of the monochromatizing stage. This provides the great advantage to perform radiometric measurements of the monochromatic X-ray photon flux with one reference detector while calibrating another X-ray detector. To achieve this, at least one secondary standard must be operated with SYMPAX. This paper presents thereby an efficiency transfer experiment between a secondary standard silicon drift detector (SDD), previously calibrated on BESSY II synchrotron Facility, and another one ("unknown" SDD), devoted to be used permanently with SYMPAX. The associated calibration process is described as well as corresponding results. Comparison with calibrated measurements performed at the Physikalisch-Technische Bundesanstalt (PTB) Radiometric Laboratory shows a very good agreement between the secondary standard and the unknown SDD.

  9. Subjective rating scales as a workload

    NASA Technical Reports Server (NTRS)

    Bird, K. L.

    1981-01-01

    A multidimensional bipolar-adjective rating scale is employed as a subjective measure of operator workload in the performance of a one-axis tracking task. The rating scale addressed several dimensions of workload, including cognitive, physical, and perceptual task loading as well as fatigue and stress effects. Eight subjects performed a one-axis tracking task (with six levels of difficulty) and rated these tasks on several workload dimensions. Performance measures were tracking error RMS (root-mean square) and the standard deviation of control stick output. Significant relationships were observed between these performance measures and skill required, task complexity, attention level, task difficulty, task demands, and stress level.

  10. An empirically derived figure of merit for the quality of overall task performance

    NASA Technical Reports Server (NTRS)

    Lemay, Moira

    1989-01-01

    The need to develop an operationally relevant figure of merit for the quality of performance of a complex system such as an aircraft cockpit stems from a hypothesized dissociation between measures of performance and those of workload. Performance can be measured in terms of time, errors, or a combination of these. In most tasks performed by expert operators, errors are relatively rare and often corrected in time to avoid consequences. Moreover, perfect performance is seldom necessary to accomplish a particular task. Moreover, how well an expert performs a complex task consisting of a series of discrete cognitive tasks superimposed on a continuous task, such as flying an aircraft, does not depend on how well each discrete task is performed, but on their smooth sequencing. This makes the amount of time spent on each subtask of paramount importance in measuring overall performance, since smooth sequencing requires a minimum amount of time spent on each task. Quality consists in getting tasks done within a crucial time interval while maintaining acceptable continuous task performance. Thus, a figure of merit for overall quality of performance should be primarily a measure of time to perform discrete subtasks combined with a measure of basic vehicle control. Thus, the proposed figure of merit requires doing a task analysis on a series of performance, or runs, of a particular task, listing each discrete task and its associated time, and calculating the mean and standard deviation of these times, along with the mean and standard deviation of tracking error for the whole task. A set of simulator data on 30 runs of a landing task was obtained and a figure of merit will be calculated for each run. The figure of merit will be compared for voice and data link, so that the impact of this technology on total crew performance (not just communication performance) can be assessed. The effect of data link communication on other cockpit tasks will also be considered.

  11. A Prototype Tool to Enable Farmers to Measure and Improve the Welfare Performance of the Farm Animal Enterprise: The Unified Field Index

    PubMed Central

    Colditz, Ian G.; Ferguson, Drewe M.; Collins, Teresa; Matthews, Lindsay; Hemsworth, Paul H.

    2014-01-01

    Simple Summary Benchmarking is a tool widely used in agricultural industries that harnesses the experience of farmers to generate knowledge of practices that lead to better on-farm productivity and performance. We propose, by analogy with production performance, a method for measuring the animal welfare performance of an enterprise and describe a tool for farmers to monitor and improve the animal welfare performance of their business. A general framework is outlined for assessing and monitoring risks to animal welfare based on measures of animals, the environment they are kept in and how they are managed. The tool would enable farmers to continually improve animal welfare. Abstract Schemes for the assessment of farm animal welfare and assurance of welfare standards have proliferated in recent years. An acknowledged short-coming has been the lack of impact of these schemes on the welfare standards achieved on farm due in part to sociological factors concerning their implementation. Here we propose the concept of welfare performance based on a broad set of performance attributes of an enterprise and describe a tool based on risk assessment and benchmarking methods for measuring and managing welfare performance. The tool termed the Unified Field Index is presented in a general form comprising three modules addressing animal, resource, and management factors. Domains within these modules accommodate the principle conceptual perspectives for welfare assessment: biological functioning; emotional states; and naturalness. Pan-enterprise analysis in any livestock sector could be used to benchmark welfare performance of individual enterprises and also provide statistics of welfare performance for the livestock sector. An advantage of this concept of welfare performance is its use of continuous scales of measurement rather than traditional pass/fail measures. Through the feedback provided via benchmarking, the tool should help farmers better engage in on-going improvement of farm practices that affect animal welfare. PMID:26480317

  12. Recommended Practice for Pressure Measurements and Calculation of Effective Pumping Speeds During Electric Propulsion Testing

    NASA Technical Reports Server (NTRS)

    Dankanich, John W.; Walker, Mitchell; Swiatek, Michael W.; Yim, John T.

    2013-01-01

    The electric propulsion community has been implored to establish and implement a set of universally applicable test standards during the research, development, and qualification of electric propulsion systems. Variability between facility-to-facility and more importantly ground-to-flight performance can result in large margins in application or aversion to mission infusion. Performance measurements and life testing under appropriate conditions can be costly and lengthy. Measurement practices must be consistent, accurate, and repeatable. Additionally, the measurements must be universally transportable across facilities throughout the development, qualification, spacecraft integration, and on-orbit performance. A recommended practice for making pressure measurements, pressure diagnostics, and calculating effective pumping speeds with justification is presented.

  13. Hand skill measurement: a gauge for treatment.

    PubMed

    Bell, E; Jurek, K; Wilson, T

    1976-02-01

    Objective measurements of performance are vital with the increasing necessity to justify the need for occupational therapy services, and to conduct studies that measure the effectiveness of treatment procedures. This paper reports on a measurement of hand skill that was standardized by comparing hand skill performance among the able-bodied, or normal, population. The performance on this test o patients with various types of disabilities and the implications for treatment are discussed. For the paraplegic, the hand skill test indicates the need for occupational therapy services; for the quadriplegic, the test measures the effectiveness of functional orthotic devices; and for the hemiplegic, the hand skill test determines the potential for success in one aspect of self-care, dressing.

  14. Propagation of uncertainty in nasal spray in vitro performance models using Monte Carlo simulation: Part II. Error propagation during product performance modeling.

    PubMed

    Guo, Changning; Doub, William H; Kauffman, John F

    2010-08-01

    Monte Carlo simulations were applied to investigate the propagation of uncertainty in both input variables and response measurements on model prediction for nasal spray product performance design of experiment (DOE) models in the first part of this study, with an initial assumption that the models perfectly represent the relationship between input variables and the measured responses. In this article, we discard the initial assumption, and extended the Monte Carlo simulation study to examine the influence of both input variable variation and product performance measurement variation on the uncertainty in DOE model coefficients. The Monte Carlo simulations presented in this article illustrate the importance of careful error propagation during product performance modeling. Our results show that the error estimates based on Monte Carlo simulation result in smaller model coefficient standard deviations than those from regression methods. This suggests that the estimated standard deviations from regression may overestimate the uncertainties in the model coefficients. Monte Carlo simulations provide a simple software solution to understand the propagation of uncertainty in complex DOE models so that design space can be specified with statistically meaningful confidence levels. (c) 2010 Wiley-Liss, Inc. and the American Pharmacists Association

  15. Hand-Held EMI Sensor Combined with Inertial Positioning for Cued UXO Discrimination - APG Standardized UXO Test Site

    DTIC Science & Technology

    2013-04-01

    Measurement Tracking System (SAINT) with an advanced hand-held, time-domain electromagnetic sensor (TEM-HH) and document classification performance at...rejecting 77% of the clutter. 15. SUBJECT TERMS EMI, electromagnetic induction, UXO classification, UXO, IMU, inertial measurement unit, 16. SECURITY...U c. THIS PAGE U UU 19b. TELEPHONE NUMBER (include area code) 919-677-1560 Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std. Z39.18

  16. In situ measurements of human articular cartilage stiffness by means of a scanning force microscope

    NASA Astrophysics Data System (ADS)

    Imer, Raphaël; Akiyama, Terunobu; de Rooij, Nico F.; Stolz, Martin; Aebi, Ueli; Kilger, Robert; Friederich, Niklaus F.; Wirz, Dieter; Daniels, A. U.; Staufer, Urs

    2007-03-01

    Osteoarthritis is a painful and disabling progressive joint disease, characterized by degradation of articular cartilage. In order to study this disease at early stages, we have miniaturized and integrated a complete scanning force microscope into a standard arthroscopic device fitting through a standard orthopedic canula. This instrument will allow orthopedic surgeons to measure the mechanical properties of articular cartilage at the nanometer and micrometer scale in-vivo during a standard arthroscopy. An orthopedic surgeon assessed the handling of the instrument. First measurements of the elasticity-modulus of human cartilage were recorded in a cadaver knee non minimal invasive. Second, minimally invasive experiments were performed using arthroscopic instruments. Load-displacement curves were successfully recorded.

  17. Development of KRISS standard reference photometer (SRP) for ambient ozone measurement

    NASA Astrophysics Data System (ADS)

    Lee, S.; Lee, J.

    2014-12-01

    Surface ozone has adverse impacts on human health and ecosystem. Accurate measurement of ambient ozone concentration is essential for developing effective mitigation strategies and understanding atmospheric chemistry. Korea Research Institute of Standards and Science (KRISS) has developed new ozone standard reference photometers (SRPs) for the calibration of ambient ozone instruments. The basic principle of the KRISS ozone SRPs is to determine the absorption of ultraviolet radiation at a specific wavelength, 253.7 nm, by ozone in the atmosphere. Ozone concentration is calculated by converting UV transmittance through the Beer-Lambert Law. This study introduces the newly developed ozone SRPs and characterizes their performance through uncertainty analysis and comparison with BIPM (International Bureau of Weights and Measures) SRP.

  18. The role of socio-communicative rearing environments in the development of social and physical cognition in apes.

    PubMed

    Russell, Jamie L; Lyn, Heidi; Schaeffer, Jennifer A; Hopkins, William D

    2011-11-01

    The cultural intelligence hypothesis (CIH) claims that humans' advanced cognition is a direct result of human culture and that children are uniquely specialized to absorb and utilize this cultural experience (Tomasello, 2000). Comparative data demonstrating that 2.5-year-old human children outperform apes on measures of social cognition but not on measures of physical cognition support this claim (Herrmann et al., 2007). However, the previous study failed to control for rearing when comparing these two species. Specifically, the human children were raised in a human culture whereas the apes were raised in standard sanctuary settings. To further explore the CIH, here we compared the performance on multiple measures of social and physical cognition in a group of standard reared apes raised in conditions typical of zoo and biomedical laboratory settings to that of apes reared in an enculturated socio-communicatively rich environment. Overall, the enculturated apes significantly outperformed their standard reared counterparts on the cognitive tasks and this was particularly true for measures of communication. Furthermore, the performance of the enculturated apes was very similar to previously reported data from 2.5-year-old children. We conclude that apes who are reared in a human-like socio-communicatively rich environment develop superior communicative abilities compared to apes reared in standard laboratory settings, which supports some assumptions of the cultural intelligence hypothesis. 2011 Blackwell Publishing Ltd.

  19. Implementation of generalized quantum measurements for unambiguous discrimination of multiple non-orthogonal coherent states.

    PubMed

    Becerra, F E; Fan, J; Migdall, A

    2013-01-01

    Generalized quantum measurements implemented to allow for measurement outcomes termed inconclusive can perform perfect discrimination of non-orthogonal states, a task which is impossible using only measurements with definitive outcomes. Here we demonstrate such generalized quantum measurements for unambiguous discrimination of four non-orthogonal coherent states and obtain their quantum mechanical description, the positive-operator valued measure. For practical realizations of this positive-operator valued measure, where noise and realistic imperfections prevent perfect unambiguous discrimination, we show that our experimental implementation outperforms any ideal standard-quantum-limited measurement performing the same non-ideal unambiguous state discrimination task for coherent states with low mean photon numbers.

  20. Educational Technology-Related Performance of Teaching Faculty in Higher Education: Implications for eLearning Management

    ERIC Educational Resources Information Center

    Larbi-Apau, Josephine A.; Guerra-Lopez, Ingrid; Moseley, James L.; Spannaus, Timothy; Yaprak, Attila

    2017-01-01

    The study examined teaching faculty's educational technology-related performances (ETRP) as a measure for predicting eLearning management in Ghana. A total of valid data (n = 164) were collected and analyzed on applied ISTE-NETS-T Performance Standards using descriptive and ANOVA statistics. Results showed an overall moderate performance with the…

  1. Spin ensemble-based AC magnetometry using concatenated dynamical decoupling at low temperatures

    NASA Astrophysics Data System (ADS)

    Farfurnik, D.; Jarmola, A.; Budker, D.; Bar-Gill, N.

    2018-01-01

    Ensembles of nitrogen-vacancy centers in diamond are widely used as AC magnetometers. While such measurements are usually performed using standard (XY) dynamical decoupling (DD) protocols at room temperature, we study the sensitivities achieved by utilizing various DD protocols, for measuring magnetic AC fields at frequencies in the 10-250 kHz range, at room temperature and 77 K. By performing measurements on an isotopically pure 12C sample, we find that the Carr-Purcell-Meiboom-Gill protocol, which is not robust against pulse imperfections, is less efficient for magnetometry than robust XY-based sequences. The concatenation of a standard XY-based protocol may enhance the sensitivities only for measuring high-frequency fields, for which many (> 500) DD pulses are necessary and the robustness against pulse imperfections is critical. Moreover, we show that cooling is effective only for measuring low-frequency fields (˜10 kHz), for which the experiment time approaches T 1 at a small number of applied DD pulses.

  2. Hospital performance measures and 30-day readmission rates.

    PubMed

    Stefan, Mihaela S; Pekow, Penelope S; Nsa, Wato; Priya, Aruna; Miller, Lauren E; Bratzler, Dale W; Rothberg, Michael B; Goldberg, Robert J; Baus, Kristie; Lindenauer, Peter K

    2013-03-01

    Lowering hospital readmission rates has become a primary target for the Centers for Medicare & Medicaid Services, but studies of the relationship between adherence to the recommended hospital care processes and readmission rates have provided inconsistent and inconclusive results. To examine the association between hospital performance on Medicare's Hospital Compare process quality measures and 30-day readmission rates for patients with acute myocardial infarction (AMI), heart failure and pneumonia, and for those undergoing major surgery. We assessed hospital performance on process measures using the 2007 Hospital Inpatient Quality Reporting Program. The process measures for each condition were aggregated in two separate measures: Overall Measure (OM) and Appropriate Care Measure (ACM) scores. Readmission rates were calculated using Medicare claims. Risk-standardized 30-day all-cause readmission rate was calculated as the ratio of predicted to expected rate standardized by the overall mean readmission rate. We calculated predicted readmission rate using hierarchical generalized linear models and adjusting for patient-level factors. Among patients aged ≥ 66 years, the median OM score ranged from 79.4 % for abdominal surgery to 95.7 % for AMI, and the median ACM scores ranged from 45.8 % for abdominal surgery to 87.9 % for AMI. We observed a statistically significant, but weak, correlation between performance scores and readmission rates for pneumonia (correlation coefficient R = 0.07), AMI (R = 0.10), and orthopedic surgery (R = 0.06). The difference in the mean readmission rate between hospitals in the 1st and 4th quartiles of process measure performance was statistically significant only for AMI (0.25 percentage points) and pneumonia (0.31 percentage points). Performance on process measures explained less than 1 % of hospital-level variation in readmission rates. Hospitals with greater adherence to recommended care processes did not achieve meaningfully better 30-day hospital readmission rates compared to those with lower levels of performance.

  3. Performing mathematics activities with non-standard units of measurement using robots controlled via speech-generating devices: three case studies.

    PubMed

    Adams, Kim D; Cook, Albert M

    2017-07-01

    Purpose To examine how using a Lego robot controlled via a speech-generating device (SGD) can contribute to how students with physical and communication impairments perform hands-on and communicative mathematics measurement activities. This study was a follow-up to a previous study. Method Three students with cerebral palsy used the robot to measure objects using non-standard units, such as straws, and then compared and ordered the objects using the resulting measurement. Their performance was assessed, and the manipulation and communication events were observed. Teachers and education assistants were interviewed regarding robot use. Results Similar benefits to the previous study were found in this study. Gaps in student procedural knowledge were identified such as knowing to place measurement units tip-to-tip, and students' reporting revealed gaps in conceptual understanding. However, performance improved with repeated practice. Stakeholders identified that some robot tasks took too long or were too difficult to perform. Conclusions Having access to both their SGD and a robot gave the students multiple ways to show their understanding of the measurement concepts. Though they could participate actively in the new mathematics activities, robot use is most appropriate in short tasks requiring reasonable operational skill. Implications for Rehabilitation Lego robots controlled via speech-generating devices (SGDs) can help students to engage in the mathematics pedagogy of performing hands-on activities while communicating about concepts. Students can "show what they know" using the Lego robots, and report and reflect on concepts using the SGD. Level 1 and Level 2 mathematics measurement activities have been adapted to be accomplished by the Lego robot. Other activities can likely be accomplished with similar robot adaptations (e.g., gripper, pen). It is not recommended to use the robot to measure items that are long, or perform measurements that require high operational competence in order to be successful.

  4. Implementation of hospital governing boards: views from the field.

    PubMed

    McNatt, Zahirah; Thompson, Jennifer W; Mengistu, Abraham; Tatek, Dawit; Linnander, Erika; Ageze, Leulseged; Lawson, Ruth; Berhanu, Negalign; Bradley, Elizabeth H

    2014-04-17

    Decentralization through the establishment of hospital governing boards has been touted as an effective way to improve the quality and efficiency of hospitals in low-income countries. Although several studies have examined the process of decentralization, few have quantitatively assessed the implementation of hospital governing boards and their impact on hospital performance. Therefore, we sought to describe the functioning of governing boards and to determine the association between governing board functioning and hospital performance. We conducted a cross-sectional study with governing board chairpersons to assess board (1) structure, (2) roles and responsibilities and (3) training and orientation practices. Using bivariate analysis and multivariable regression, we examined the association between governing board functioning and hospital performance. Hospital performance indicators: 1) percent of hospital management standards met, measured with the Ethiopian Hospital Reform Implementation Guidelines and 2) patient experience, measured with the Inpatient and Outpatient Assessment of Healthcare surveys. A total of 92 boards responded to the survey (96% response rate). The average percentage of EHRIG standards met was 58.1% (standard deviation (SD) 21.7 percentage points), and the mean overall patient experience score was 7.2 (SD 2.2). Hospitals with greater hospital management standards met had governing boards that paid members, reviewed performance in several domains quarterly or more frequently, developed new revenue sources, determined services to be outsourced, reviewed patient complaints, and had members with knowledge in business and financial management (all P-values < 0.05). Hospitals with more positive patient experience had governing boards that developed new revenue sources, determined services to be outsourced, and reviewed patient complaints (all P-values < 0.05). These cross-sectional data suggest that strengthening governing boards to perform essential responsibilities may result in improved hospital performance.

  5. Cognitive skills, student achievement tests, and schools.

    PubMed

    Finn, Amy S; Kraft, Matthew A; West, Martin R; Leonard, Julia A; Bish, Crystal E; Martin, Rebecca E; Sheridan, Margaret A; Gabrieli, Christopher F O; Gabrieli, John D E

    2014-03-01

    Cognitive skills predict academic performance, so schools that improve academic performance might also improve cognitive skills. To investigate the impact schools have on both academic performance and cognitive skills, we related standardized achievement-test scores to measures of cognitive skills in a large sample (N = 1,367) of eighth-grade students attending traditional, exam, and charter public schools. Test scores and gains in test scores over time correlated with measures of cognitive skills. Despite wide variation in test scores across schools, differences in cognitive skills across schools were negligible after we controlled for fourth-grade test scores. Random offers of enrollment to oversubscribed charter schools resulted in positive impacts of such school attendance on math achievement but had no impact on cognitive skills. These findings suggest that schools that improve standardized achievement-test scores do so primarily through channels other than improving cognitive skills.

  6. Chapter 23: International Standard reagents for harmonization of HPV serology and DNA assays--an update.

    PubMed

    Pagliusi, Sonia R; Dillner, Joakim; Pawlita, Michael; Quint, Wim G V; Wheeler, Cosette M; Ferguson, M

    2006-08-31

    International reference materials such as International Standard reagents facilitate quality assurance of essential biopharmaceutical products and related in vitro diagnostic tests. Standardization of antibody and DNA measurements and harmonization of laboratory procedures are key to the success of cancer prevention strategies through screening methods as well as for development and implementation of vaccination against the human papillomavirus (HPV). The WHO supported the preparation and initial analysis of a panel of candidate serological and DNA reference reagents aimed at facilitating inter-laboratory comparisons and detection of HPV worldwide. Two international collaborative studies assessed the performance of various HPV antibody and HPV-DNA detection assays and examined the feasibility of generating HPV antibody and DNA standard reagents. These studies showed that improvement in performance and comparability of assays is urgently needed and that the use of the same International Standard reference reagent could significantly improve performance and comparability. It is hoped that the establishment of International Units and International Standards for HPV antibody and DNA analysis will be pursued with high priority.

  7. Selection Process for New Windows | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  8. Design Guidance for New Windows | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  9. Selection Process for Replacement Windows | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  10. Design Guidance for Replacement Windows | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  11. 77 FR 73454 - Revision of Information Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-10

    ... ensure that requested data can be provided in the desired format, reporting burden (time and financial... with standard national performance measure requirements; revise the Grant Application Narrative... express the desired outcomes; Facilitate stronger alignment between narrative sections and the performance...

  12. Solar Heat Gain Coefficient (SHGC) | Efficient Windows Collaborative

    Science.gov Websites

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  13. INTERNATIONAL STANDARDS ON FOOD AND ENVIRONMENTAL RADIOACTIVITY MEASUREMENT FOR RADIOLOGICAL PROTECTION: STATUS AND PERSPECTIVES.

    PubMed

    Calmet, D; Ameon, R; Bombard, A; Brun, S; Byrde, F; Chen, J; Duda, J-M; Forte, M; Fournier, M; Fronka, A; Haug, T; Herranz, M; Husain, A; Jerome, S; Jiranek, M; Judge, S; Kim, S B; Kwakman, P; Loyen, J; LLaurado, M; Michel, R; Porterfield, D; Ratsirahonana, A; Richards, A; Rovenska, K; Sanada, T; Schuler, C; Thomas, L; Tokonami, S; Tsapalov, A; Yamada, T

    2017-04-01

    Radiological protection is a matter of concern for members of the public and thus national authorities are more likely to trust the quality of radioactivity data provided by accredited laboratories using common standards. Normative approach based on international standards aims to ensure the accuracy or validity of the test result through calibrations and measurements traceable to the International System of Units. This approach guarantees that radioactivity test results on the same types of samples are comparable over time and space as well as between different testing laboratories. Today, testing laboratories involved in radioactivity measurement have a set of more than 150 international standards to help them perform their work. Most of them are published by the International Standardization Organization (ISO) and the International Electrotechnical Commission (IEC). This paper reviews the most essential ISO standards that give guidance to testing laboratories at different stages from sampling planning to the transmission of the test report to their customers, summarizes recent activities and achievements and present the perspectives on new standards under development by the ISO Working Groups dealing with radioactivity measurement in connection with radiological protection. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. The role of standards in the development and implementation of clinical laboratory tests: a domestic and global perspective.

    PubMed

    Michaud, Ginette Y

    2005-01-01

    In the field of clinical laboratory medicine, standardization is aimed at increasing the trueness and reliability of measured values. Standardization relies on the use of written standards, reference measurement procedures and reference materials. These are important tools for the design and validation of new tests, and for establishing the metrological traceability of diagnostic assays. Their use supports the translation of research technologies into new diagnostic assays and leads to more rapid advances in science and medicine, as well as improvements in the quality of patient care. The various standardization tools are described, as are the procedures by which written standards, reference procedures and reference materials are developed. Recent efforts to develop standards for use in the field of molecular diagnostics are discussed. The recognition of standardization tools by the FDA and other regulatory authorities is noted as evidence of their important role in ensuring the safety and performance of in vitro diagnostic devices.

  15. Specular gloss scales comparison between the SIMT and the NIST

    NASA Astrophysics Data System (ADS)

    Yin, Dejin; Li, Tiecheng; Huang, Biyong; Cheng, Weihai; Lin, Fangsheng

    2016-09-01

    Specular gloss is the fraction of light reflected in the specular direction for specified incident and receptor apertures, it is the perception by an observer of the mirror-like appearance of a surface. The measurement of specular gloss consists of comparing the luminous reflectance from a test sample to that from a calibrated gloss standard which generally is a polished piece of black glass, under the same experimental conditions. Gloss is a dimensionless quantity whose accurate determination requires standardized experimental conditions such as spectral distribution of the incident beam of light, incident and viewing angles, and a gloss standard. The Shanghai Institute of Measurement and Testing Technology (SIMT) provides test service to calibrate gloss reference standards. This facility is built around a reference goniophotometer, containing an instrument that measures flux as a function of angles of illumination or observation and a primary gloss standard, which is a piece of three wedges of highly polished, high-quality optical glass. The system has an overall (k=2) uncertainty of 0.5 Gloss Unit(GU). The service offers calibration measurements of working gloss standards at the geometries of 20°, 60°, and 85°, in compliance with the ISO 2813 and the ASTM D523 documentary standards. This article describes a bilateral comparison of specular gloss scales between SIMT and the National Institute of Standards and Technology (NIST) that has been performed. The results of this comparison show agreement within the combined uncertainties for the measurement of specular gloss of highly polished black glass.

  16. The Future of Classification in Wheelchair Sports; Can Data Science and Technological Advancement Offer an Alternative Point of View?

    PubMed

    van der Slikke, Rienk M A; Bregman, Daan J J; Berger, Monique A M; de Witte, Annemarie M H; Veeger, Dirk-Jan H E J

    2017-11-01

    Classification is a defining factor for competition in wheelchair sports, but it is a delicate and time-consuming process with often questionable validity. 1 New inertial sensor based measurement methods applied in match play and field tests, allow for more precise and objective estimates of the impairment effect on wheelchair mobility performance. It was evaluated if these measures could offer an alternative point of view for classification. Six standard wheelchair mobility performance outcomes of different classification groups were measured in match play (n=29), as well as best possible performance in a field test (n=47). In match-results a clear relationship between classification and performance level is shown, with increased performance outcomes in each adjacent higher classification group. Three outcomes differed significantly between the low and mid-class groups, and one between the mid and high-class groups. In best performance (field test), a split between the low and mid-class groups shows (5 out of 6 outcomes differed significantly) but hardly any difference between the mid and high-class groups. This observed split was confirmed by cluster analysis, revealing the existence of only two performance based clusters. The use of inertial sensor technology to get objective measures of wheelchair mobility performance, combined with a standardized field-test, brought alternative views for evidence based classification. The results of this approach provided arguments for a reduced number of classes in wheelchair basketball. Future use of inertial sensors in match play and in field testing could enhance evaluation of classification guidelines as well as individual athlete performance.

  17. The Applicability of Standard Error of Measurement and Minimal Detectable Change to Motor Learning Research-A Behavioral Study.

    PubMed

    Furlan, Leonardo; Sterr, Annette

    2018-01-01

    Motor learning studies face the challenge of differentiating between real changes in performance and random measurement error. While the traditional p -value-based analyses of difference (e.g., t -tests, ANOVAs) provide information on the statistical significance of a reported change in performance scores, they do not inform as to the likely cause or origin of that change, that is, the contribution of both real modifications in performance and random measurement error to the reported change. One way of differentiating between real change and random measurement error is through the utilization of the statistics of standard error of measurement (SEM) and minimal detectable change (MDC). SEM is estimated from the standard deviation of a sample of scores at baseline and a test-retest reliability index of the measurement instrument or test employed. MDC, in turn, is estimated from SEM and a degree of confidence, usually 95%. The MDC value might be regarded as the minimum amount of change that needs to be observed for it to be considered a real change, or a change to which the contribution of real modifications in performance is likely to be greater than that of random measurement error. A computer-based motor task was designed to illustrate the applicability of SEM and MDC to motor learning research. Two studies were conducted with healthy participants. Study 1 assessed the test-retest reliability of the task and Study 2 consisted in a typical motor learning study, where participants practiced the task for five consecutive days. In Study 2, the data were analyzed with a traditional p -value-based analysis of difference (ANOVA) and also with SEM and MDC. The findings showed good test-retest reliability for the task and that the p -value-based analysis alone identified statistically significant improvements in performance over time even when the observed changes could in fact have been smaller than the MDC and thereby caused mostly by random measurement error, as opposed to by learning. We suggest therefore that motor learning studies could complement their p -value-based analyses of difference with statistics such as SEM and MDC in order to inform as to the likely cause or origin of any reported changes in performance.

  18. Emergent Modelling: From Traditional Indonesian Games to a Standard Unit of Measurement

    ERIC Educational Resources Information Center

    Wijaya, Ariyadi; Doorman, L. Michiel; Keijze, Ronald

    2011-01-01

    In this paper, we describe the way in which traditional Indonesian games can support the learning of linear measurement. Previous research has revealed that young children tend to perform measurement as an instrumental procedure. This tendency may be due to the way in which linear measurement has been taught as an isolated concept, which is…

  19. A Review of NIST Primary Activity Standards for 18F: 1982 to 2013

    PubMed Central

    Bergeron, Denis E; Cessna, Jeffrey T; Coursey, Bert M; Fitzgerald, Ryan; Zimmerman, Brian E

    2014-01-01

    The new NIST activity standardization for 18F, described in 2014 in Applied Radiation and Isotopes (v. 85, p. 77), differs from results obtained between 1998 and 2008 by 4 %. The new results are considered to be very reliable; they are based on a battery of robust primary measurement techniques and bring the NIST standard into accord with other national metrology institutes. This paper reviews all ten 18F activity standardizations performed at NIST from 1982 to 2013, with a focus on experimental variables that might account for discrepancies. We have identified many possible sources of measurement bias and eliminated most of them, but we have not adequately accounted for the 1998–2008 results. PMID:26601035

  20. Assessing Troubleshooting Proficiency: Application of a General Strategy for Work Performance Measurement

    ERIC Educational Resources Information Center

    Finch, Curtis R.; O'Reilly, Patrick A.

    1974-01-01

    The measure was designed to be able to evaluate a student's ability to find troubles in an automobile engine, to be appropriate at a variety of geographic sites, and to meet certain validity and reliability standards. (AG)

  1. Method of calculation overall equipment effectiveness in fertilizer factory

    NASA Astrophysics Data System (ADS)

    Siregar, I.; Muchtar, M. A.; Rahmat, R. F.; Andayani, U.; Nasution, T. H.; Sari, R. M.

    2018-02-01

    This research was conducted at a fertilizer company in Sumatra, where companies that produce fertilizers in large quantities to meet the needs of consumers. This company cannot be separated from issues related to the performance/effectiveness of the machinery and equipment. It can be seen from the engine that runs every day without a break resulted in not all of the quality of products in accordance with the quality standards set by the company. Therefore, to measure and improve the performance of the machine in the unit Plant Urea-1 as a whole then used method of Overall Equipment Effectiveness (OEE), which is one important element in the Total Productive Maintenance (TPM) to measure the effectiveness of the machine so that it can take measures to maintain that level. In July, August and September OEE values above the standard set at 85%. Meanwhile, in October, November and December have not reached the standard OEE values. The low value of OEE due to lack of time availability of machines for the production shut down due to the occurrence of the engine long enough so that the availability of reduced production time.

  2. UK key performance indicators and quality assurance standards for colonoscopy.

    PubMed

    Rees, Colin J; Thomas Gibson, Siwan; Rutter, Matt D; Baragwanath, Phil; Pullan, Rupert; Feeney, Mark; Haslam, Neil

    2016-12-01

    Colonoscopy should be delivered by endoscopists performing high quality procedures. The British Society of Gastroenterology, the UK Joint Advisory Group on GI Endoscopy, and the Association of Coloproctology of Great Britain and Ireland have developed quality assurance measures and key performance indicators for the delivery of colonoscopy within the UK. This document sets minimal standards for delivery of procedures along with aspirational targets that all endoscopists should aim for. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  3. Obtaining greater value from health care: the roles of the U.S. government.

    PubMed

    Schoenbaum, Stephen C; Audet, Anne-Marie J; Davis, Karen

    2003-01-01

    The problems of quality and cost in the U.S. health care system are unlikely to be solved without strong leadership from the federal government, which can mobilize action to set national priorities for quality; develop and promulgate standards for care; and stimulate implementation of performance measures and standards for providers. All of these functions would best be carried out by a new federal agency. Furthermore, the federal government should design payment policies based on the performance standards, invest in needed information technology, and invest in research related to improving care and in training professionals to support nationwide quality improvement.

  4. A computational framework for converting textual clinical diagnostic criteria into the quality data model.

    PubMed

    Hong, Na; Li, Dingcheng; Yu, Yue; Xiu, Qiongying; Liu, Hongfang; Jiang, Guoqian

    2016-10-01

    Constructing standard and computable clinical diagnostic criteria is an important but challenging research field in the clinical informatics community. The Quality Data Model (QDM) is emerging as a promising information model for standardizing clinical diagnostic criteria. To develop and evaluate automated methods for converting textual clinical diagnostic criteria in a structured format using QDM. We used a clinical Natural Language Processing (NLP) tool known as cTAKES to detect sentences and annotate events in diagnostic criteria. We developed a rule-based approach for assigning the QDM datatype(s) to an individual criterion, whereas we invoked a machine learning algorithm based on the Conditional Random Fields (CRFs) for annotating attributes belonging to each particular QDM datatype. We manually developed an annotated corpus as the gold standard and used standard measures (precision, recall and f-measure) for the performance evaluation. We harvested 267 individual criteria with the datatypes of Symptom and Laboratory Test from 63 textual diagnostic criteria. We manually annotated attributes and values in 142 individual Laboratory Test criteria. The average performance of our rule-based approach was 0.84 of precision, 0.86 of recall, and 0.85 of f-measure; the performance of CRFs-based classification was 0.95 of precision, 0.88 of recall and 0.91 of f-measure. We also implemented a web-based tool that automatically translates textual Laboratory Test criteria into the QDM XML template format. The results indicated that our approaches leveraging cTAKES and CRFs are effective in facilitating diagnostic criteria annotation and classification. Our NLP-based computational framework is a feasible and useful solution in developing diagnostic criteria representation and computerization. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Performance Evaluation of Five Turbidity Sensors in Three Primary Standards

    USGS Publications Warehouse

    Snazelle, Teri T.

    2015-10-28

    Open-File Report 2015-1172 is temporarily unavailable.Five commercially available turbidity sensors were evaluated by the U.S. Geological Survey, Hydrologic Instrumentation Facility (HIF) for accuracy and precision in three types of turbidity standards; formazin, StablCal, and AMCO Clear (AMCO–AEPA). The U.S. Environmental Protection Agency (EPA) recognizes all three turbidity standards as primary standards, meaning they are acceptable for reporting purposes. The Forrest Technology Systems (FTS) DTS-12, the Hach SOLITAX sc, the Xylem EXO turbidity sensor, the Yellow Springs Instrument (YSI) 6136 turbidity sensor, and the Hydrolab Series 5 self-cleaning turbidity sensor were evaluated to determine if turbidity measurements in the three primary standards are comparable to each other, and to ascertain if the primary standards are truly interchangeable. A formazin 4000 nephelometric turbidity unit (NTU) stock was purchased and dilutions of 40, 100, 400, 800, and 1000 NTU were made fresh the day of testing. StablCal and AMCO Clear (for Hach 2100N) standards with corresponding concentrations were also purchased for the evaluation. Sensor performance was not evaluated in turbidity levels less than 40 NTU due to the unavailability of polymer-bead turbidity standards rated for general use. The percent error was calculated as the true (not absolute) difference between the measured turbidity and the standard value, divided by the standard value.The sensors that demonstrated the best overall performance in the evaluation were the Hach SOLITAX and the Hydrolab Series 5 turbidity sensor when the operating range (0.001–4000 NTU for the SOLITAX and 0.1–3000 NTU for the Hydrolab) was considered in addition to sensor accuracy and precision. The average percent error in the three standards was 3.80 percent for the SOLITAX and -4.46 percent for the Hydrolab. The DTS-12 also demonstrated good accuracy with an average percent error of 2.02 percent and a maximum relative standard deviation of 0.51 percent for the operating range, which was limited to 0.01–1600 NTU at the time of this report. Test results indicated an average percent error of 19.81 percent in the three standards for the EXO turbidity sensor and 9.66 percent for the YSI 6136. The significant variability in sensor performance in the three primary standards suggests that although all three types are accepted as primary calibration standards, they are not interchangeable, and sensor results in the three types of standards are not directly comparable.

  6. Influence of scan mode (180°/360°) of the cone beam computed tomography for preoperative dental implant measurements.

    PubMed

    Neves, Frederico S; Vasconcelos, Taruska V; Campos, Paulo S F; Haiter-Neto, Francisco; Freitas, Deborah Q

    2014-02-01

    The aim of this study was to evaluate the effect of scan mode of the cone beam computed tomography (CBCT) in the preoperative dental implant measurements. Completely edentulous mandibles with entirely resorbed alveolar processes were selected for this study. Five regions were selected (incisor, canine, premolar, first molar, and second molar). The mandibles were scanned with Next Generation i-CAT CBCT unit (Imaging Sciences International, Inc, Hatfield, PA, USA) with half (180°) and full (360°) mode. Two oral radiologists performed vertical measurements in all selected regions; the measurements of half of the sample were repeated within an interval of 30 days. The mandibles were sectioned using an electrical saw in all evaluated regions to obtain the gold standard. The intraclass correlation coefficient was calculated for the intra- and interobserver agreement. Descriptive statistics were calculated as mean, median, and standard deviation. Wilcoxon signed rank test was used to determine the correlation between the measurements obtained in different scan mode with the gold standard. The significance level was 5%. The values of intra- and interobserver reproducibility indicated a strong agreement. In the dental implant measurements, except the bone height of the second molar region in full scan mode (P = 0.02), the Wilcoxon signed rank test did not show statistical significant difference with the gold standard (P > 0.05). Both modes provided real measures, necessary when performing implant planning; however, half scan mode uses smaller doses, following the principle of effectiveness. We believe that this method should be used because of the best dose-effect relationship and offer less risk to the patient. © 2012 John Wiley & Sons A/S.

  7. Development of a Hospital Outcome Measure Intended for Use With Electronic Health Records: 30-Day Risk-standardized Mortality After Acute Myocardial Infarction.

    PubMed

    McNamara, Robert L; Wang, Yongfei; Partovian, Chohreh; Montague, Julia; Mody, Purav; Eddy, Elizabeth; Krumholz, Harlan M; Bernheim, Susannah M

    2015-09-01

    Electronic health records (EHRs) offer the opportunity to transform quality improvement by using clinical data for comparing hospital performance without the burden of chart abstraction. However, current performance measures using EHRs are lacking. With support from the Centers for Medicare & Medicaid Services (CMS), we developed an outcome measure of hospital risk-standardized 30-day mortality rates for patients with acute myocardial infarction for use with EHR data. As no appropriate source of EHR data are currently available, we merged clinical registry data from the Action Registry-Get With The Guidelines with claims data from CMS to develop the risk model (2009 data for development, 2010 data for validation). We selected candidate variables that could be feasibly extracted from current EHRs and do not require changes to standard clinical practice or data collection. We used logistic regression with stepwise selection and bootstrapping simulation for model development. The final risk model included 5 variables available on presentation: age, heart rate, systolic blood pressure, troponin ratio, and creatinine level. The area under the receiver operating characteristic curve was 0.78. Hospital risk-standardized mortality rates ranged from 9.6% to 13.1%, with a median of 10.7%. The odds of mortality for a high-mortality hospital (+1 SD) were 1.37 times those for a low-mortality hospital (-1 SD). This measure represents the first outcome measure endorsed by the National Quality Forum for public reporting of hospital quality based on clinical data in the EHR. By being compatible with current clinical practice and existing EHR systems, this measure is a model for future quality improvement measures.

  8. Tests of stepping as indicators of mobility, balance, and fall risk in balance-impaired older adults.

    PubMed

    Cho, Be-long; Scarpace, Diane; Alexander, Neil B

    2004-07-01

    To determine the relationships between two tests of stepping ability (the maximal step length (MSL) and rapid step test (RST)) and standard tests of standing balance, gait, mobility, and functional impairment in a group of at-risk older adults. Cross-sectional study. University-based laboratory. One hundred sixty-seven mildly balance-impaired older adults recruited for a balance-training and fall-reduction program (mean age 78, range 65-90). Measures of stepping maximally (MSL, the ability to maximally step out and return to the initial position) and rapidly (RST, the time taken to step out and return in multiple directions as fast as possible); standard measures of balance, gait, and mobility including timed tandem stance (TS), tandem walk (TW, both timing and errors), timed unipedal stance (US), timed up and go (TUG), performance oriented mobility assessment (POMA), and 6-minute walk (SMW); measures of leg strength (peak knee and ankle torque and power at slow and fast speeds); self-report measures of frequent falls (>2 per 12 months), disability (Established Population for Epidemiologic Studies of the Elderly (EPESE) physical function), and confidence to avoid falls (Activity-specific Balance Confidence (ABC) Scale). Spearman and Pearson correlation, intraclass correlation coefficient, logistic regression, and linear regression were used for data analysis. MSL consistently predicted a number of self-report and performance measures at least as well as other standard balance measures. MSL correlations with EPESE physical function, ABC, TUG, and POMA scores; SMW; and peak maximum knee and ankle torque and power were at least as high as those correlations seen with TS, TW, or US. MSL score was associated with the risk of being a frequent faller. In addition, the six MSL directions were highly correlated (up to 0.96), and any one of the leg directions yielded similar relationships with functional measures and a history of falls. Relationships between RST and these measures were relatively modest. MSL is as good a predictor of mobility performance, frequent falls, self-reported function, and balance confidence as standard stance tests such as US. MSL simplified to one direction may be a useful clinical indicator of mobility, balance, and fall risk in older adults.

  9. Creating NDA working standards through high-fidelity spent fuel modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Skutnik, Steven E; Gauld, Ian C; Romano, Catherine E

    2012-01-01

    The Next Generation Safeguards Initiative (NGSI) is developing advanced non-destructive assay (NDA) techniques for spent nuclear fuel assemblies to advance the state-of-the-art in safeguards measurements. These measurements aim beyond the capabilities of existing methods to include the evaluation of plutonium and fissile material inventory, independent of operator declarations. Testing and evaluation of advanced NDA performance will require reference assemblies with well-characterized compositions to serve as working standards against which the NDA methods can be benchmarked and for uncertainty quantification. To support the development of standards for the NGSI spent fuel NDA project, high-fidelity modeling of irradiated fuel assemblies is beingmore » performed to characterize fuel compositions and radiation emission data. The assembly depletion simulations apply detailed operating history information and core simulation data as it is available to perform high fidelity axial and pin-by-pin fuel characterization for more than 1600 nuclides. The resulting pin-by-pin isotopic inventories are used to optimize the NDA measurements and provide information necessary to unfold and interpret the measurement data, e.g., passive gamma emitters, neutron emitters, neutron absorbers, and fissile content. A key requirement of this study is the analysis of uncertainties associated with the calculated compositions and signatures for the standard assemblies; uncertainties introduced by the calculation methods, nuclear data, and operating information. An integral part of this assessment involves the application of experimental data from destructive radiochemical assay to assess the uncertainty and bias in computed inventories, the impact of parameters such as assembly burnup gradients and burnable poisons, and the influence of neighboring assemblies on periphery rods. This paper will present the results of high fidelity assembly depletion modeling and uncertainty analysis from independent calculations performed using SCALE and MCNP. This work is supported by the Next Generation Safeguards Initiative, Office of Nuclear Safeguards and Security, National Nuclear Security Administration.« less

  10. Pitfalls in the measurement of muscle mass: a need for a reference standard

    PubMed Central

    Landi, Francesco; Cesari, Matteo; Fielding, Roger A.; Visser, Marjolein; Engelke, Klaus; Maggi, Stefania; Dennison, Elaine; Al‐Daghri, Nasser M.; Allepaerts, Sophie; Bauer, Jurgen; Bautmans, Ivan; Brandi, Maria Luisa; Bruyère, Olivier; Cederholm, Tommy; Cerreta, Francesca; Cherubini, Antonio; Cooper, Cyrus; Cruz‐Jentoft, Alphonso; McCloskey, Eugene; Dawson‐Hughes, Bess; Kaufman, Jean‐Marc; Laslop, Andrea; Petermans, Jean; Reginster, Jean‐Yves; Rizzoli, René; Robinson, Sian; Rolland, Yves; Rueda, Ricardo; Vellas, Bruno; Kanis, John A.

    2018-01-01

    Abstract Background All proposed definitions of sarcopenia include the measurement of muscle mass, but the techniques and threshold values used vary. Indeed, the literature does not establish consensus on the best technique for measuring lean body mass. Thus, the objective measurement of sarcopenia is hampered by limitations intrinsic to assessment tools. The aim of this study was to review the methods to assess muscle mass and to reach consensus on the development of a reference standard. Methods Literature reviews were performed by members of the European Society for Clinical and Economic Aspects of Osteoporosis and Osteoarthritis working group on frailty and sarcopenia. Face‐to‐face meetings were organized for the whole group to make amendments and discuss further recommendations. Results A wide range of techniques can be used to assess muscle mass. Cost, availability, and ease of use can determine whether the techniques are better suited to clinical practice or are more useful for research. No one technique subserves all requirements but dual energy X‐ray absorptiometry could be considered as a reference standard (but not a gold standard) for measuring muscle lean body mass. Conclusions Based on the feasibility, accuracy, safety, and low cost, dual energy X‐ray absorptiometry can be considered as the reference standard for measuring muscle mass. PMID:29349935

  11. Development and Validation of a Rapid (13)C6-Glucose Isotope Dilution UPLC-MRM Mass Spectrometry Method for Use in Determining System Accuracy and Performance of Blood Glucose Monitoring Devices.

    PubMed

    Matsunami, Risë K; Angelides, Kimon; Engler, David A

    2015-05-18

    There is currently considerable discussion about the accuracy of blood glucose concentrations determined by personal blood glucose monitoring systems (BGMS). To date, the FDA has allowed new BGMS to demonstrate accuracy in reference to other glucose measurement systems that use the same or similar enzymatic-based methods to determine glucose concentration. These types of reference measurement procedures are only comparative in nature and are subject to the same potential sources of error in measurement and system perturbations as the device under evaluation. It would be ideal to have a completely orthogonal primary method that could serve as a true standard reference measurement procedure for establishing the accuracy of new BGMS. An isotope-dilution liquid chromatography/mass spectrometry (ID-UPLC-MRM) assay was developed using (13)C6-glucose as a stable isotope analogue to specifically measure glucose concentration in human plasma, and validated for use against NIST standard reference materials, and against fresh isolates of whole blood and plasma into which exogenous glucose had been spiked. Assay performance was quantified to NIST-traceable dry weight measures for both glucose and (13)C6-glucose. The newly developed assay method was shown to be rapid, highly specific, sensitive, accurate, and precise for measuring plasma glucose levels. The assay displayed sufficient dynamic range and linearity to measure across the range of both normal and diabetic blood glucose levels. Assay performance was measured to within the same uncertainty levels (<1%) as the NIST definitive method for glucose measurement in human serum. The newly developed ID UPLC-MRM assay can serve as a validated reference measurement procedure to which new BGMS can be assessed for glucose measurement performance. © 2015 Diabetes Technology Society.

  12. Development and Validation of a Rapid 13C6-Glucose Isotope Dilution UPLC-MRM Mass Spectrometry Method for Use in Determining System Accuracy and Performance of Blood Glucose Monitoring Devices

    PubMed Central

    Matsunami, Risë K.; Angelides, Kimon; Engler, David A.

    2015-01-01

    Background: There is currently considerable discussion about the accuracy of blood glucose concentrations determined by personal blood glucose monitoring systems (BGMS). To date, the FDA has allowed new BGMS to demonstrate accuracy in reference to other glucose measurement systems that use the same or similar enzymatic-based methods to determine glucose concentration. These types of reference measurement procedures are only comparative in nature and are subject to the same potential sources of error in measurement and system perturbations as the device under evaluation. It would be ideal to have a completely orthogonal primary method that could serve as a true standard reference measurement procedure for establishing the accuracy of new BGMS. Methods: An isotope-dilution liquid chromatography/mass spectrometry (ID-UPLC-MRM) assay was developed using 13C6-glucose as a stable isotope analogue to specifically measure glucose concentration in human plasma, and validated for use against NIST standard reference materials, and against fresh isolates of whole blood and plasma into which exogenous glucose had been spiked. Assay performance was quantified to NIST-traceable dry weight measures for both glucose and 13C6-glucose. Results: The newly developed assay method was shown to be rapid, highly specific, sensitive, accurate, and precise for measuring plasma glucose levels. The assay displayed sufficient dynamic range and linearity to measure across the range of both normal and diabetic blood glucose levels. Assay performance was measured to within the same uncertainty levels (<1%) as the NIST definitive method for glucose measurement in human serum. Conclusions: The newly developed ID UPLC-MRM assay can serve as a validated reference measurement procedure to which new BGMS can be assessed for glucose measurement performance. PMID:25986627

  13. Accuracy of two osmometers on standard samples: electrical impedance technique and freezing point depression technique

    NASA Astrophysics Data System (ADS)

    García-Resúa, Carlos; Pena-Verdeal, Hugo; Miñones, Mercedes; Gilino, Jorge; Giraldez, Maria J.; Yebra-Pimentel, Eva

    2013-11-01

    High tear fluid osmolarity is a feature common to all types of dry eye. This study was designed to establish the accuracy of two osmometers, a freezing point depression osmometer (Fiske 110) and an electrical impedance osmometer (TearLab™) by using standard samples. To assess the accuracy of the measurements provided by the two instruments we used 5 solutions of known osmolarity/osmolality; 50, 290 and 850 mOsm/kg and 292 and 338 mOsm/L. Fiske 110 is designed to be used in samples of 20 μl, so measurements were made on 1:9, 1:4, 1:1 and 1:0 dilutions of the standards. Tear Lab is addressed to be used in tear film and only a sample of 0.05 μl is required, so no dilutions were employed. Due to the smaller measurement range of the TearLab, the 50 and 850 mOsm/kg standards were not included. 20 measurements per standard sample were used and differences with the reference value was analysed by one sample t-test. Fiske 110 showed that osmolarity measurements differed statistically from standard values except those recorded for 290 mOsm/kg standard diluted 1:1 (p = 0.309), the 292 mOsm/L H2O sample (1:1) and 338 mOsm/L H2O standard (1:4). The more diluted the sample, the higher the error rate. For the TearLab measurements, one-sample t-test indicated that all determinations differed from the theoretical values (p = 0.001), though differences were always small. For undiluted solutions, Fiske 110 shows similar performance than TearLab. However, for the diluted standards, Fiske 110 worsens.

  14. Silicon solar cell process. Development, fabrication and analysis

    NASA Technical Reports Server (NTRS)

    Yoo, H. I.; Iles, P. A.; Tanner, D. P.

    1978-01-01

    Solar cells were fabricated from unconventional silicon sheets, and the performances were characterized with an emphasis on statistical evaluation. A number of solar cell fabrication processes were used and conversion efficiency was measured under AMO condition at 25 C. Silso solar cells using standard processing showed an average efficiency of about 9.6%. Solar cells with back surface field process showed about the same efficiency as the cells from standard process. Solar cells from grain boundary passivation process did not show any improvements in solar cell performance.

  15. An ROC-type measure of diagnostic accuracy when the gold standard is continuous-scale.

    PubMed

    Obuchowski, Nancy A

    2006-02-15

    ROC curves and summary measures of accuracy derived from them, such as the area under the ROC curve, have become the standard for describing and comparing the accuracy of diagnostic tests. Methods for estimating ROC curves rely on the existence of a gold standard which dichotomizes patients into disease present or absent. There are, however, many examples of diagnostic tests whose gold standards are not binary-scale, but rather continuous-scale. Unnatural dichotomization of these gold standards leads to bias and inconsistency in estimates of diagnostic accuracy. In this paper, we propose a non-parametric estimator of diagnostic test accuracy which does not require dichotomization of the gold standard. This estimator has an interpretation analogous to the area under the ROC curve. We propose a confidence interval for test accuracy and a statistical test for comparing accuracies of tests from paired designs. We compare the performance (i.e. CI coverage, type I error rate, power) of the proposed methods with several alternatives. An example is presented where the accuracies of two quick blood tests for measuring serum iron concentrations are estimated and compared.

  16. Diffusing-wave spectroscopy in a standard dynamic light scattering setup

    NASA Astrophysics Data System (ADS)

    Fahimi, Zahra; Aangenendt, Frank J.; Voudouris, Panayiotis; Mattsson, Johan; Wyss, Hans M.

    2017-12-01

    Diffusing-wave spectroscopy (DWS) extends dynamic light scattering measurements to samples with strong multiple scattering. DWS treats the transport of photons through turbid samples as a diffusion process, thereby making it possible to extract the dynamics of scatterers from measured correlation functions. The analysis of DWS data requires knowledge of the path length distribution of photons traveling through the sample. While for flat sample cells this path length distribution can be readily calculated and expressed in analytical form; no such expression is available for cylindrical sample cells. DWS measurements have therefore typically relied on dedicated setups that use flat sample cells. Here we show how DWS measurements, in particular DWS-based microrheology measurements, can be performed in standard dynamic light scattering setups that use cylindrical sample cells. To do so we perform simple random-walk simulations that yield numerical predictions of the path length distribution as a function of both the transport mean free path and the detection angle. This information is used in experiments to extract the mean-square displacement of tracer particles in the material, as well as the corresponding frequency-dependent viscoelastic response. An important advantage of our approach is that by performing measurements at different detection angles, the average path length through the sample can be varied. For measurements performed on a single sample cell, this gives access to a wider range of length and time scales than obtained in a conventional DWS setup. Such angle-dependent measurements also offer an important consistency check, as for all detection angles the DWS analysis should yield the same tracer dynamics, even though the respective path length distributions are very different. We validate our approach by performing measurements both on aqueous suspensions of tracer particles and on solidlike gelatin samples, for which we find our DWS-based microrheology data to be in good agreement with rheological measurements performed on the same samples.

  17. Towards Modernizing the Characterization of Shock and Detonation Physics Performance via Novel Diagnostics and Tests

    NASA Astrophysics Data System (ADS)

    Salyer, Terry

    2017-06-01

    For the bulk of detonation performance experiments, a fairly basic set of diagnostic techniques has evolved as the standard for acquiring the necessary measurements. Gold standard techniques such as pin switches and streak cameras still produce the high-quality data required, yet much room remains for improvement with regard to ease of use, cost of fielding, breadth of data, and diagnostic versatility. Over the past several years, an alternate set of diagnostics has been under development to replace many of these traditional techniques. Pulse Correlation Reflectometry (PCR) is a capable substitute for pin switches with the advantage of obtaining orders of magnitude more data at a small fraction of the cost and fielding time. Spectrally Encoded Imaging (SEI) can replace most applications of streak camera with the advantage of imaging surfaces through a single optical fiber that are otherwise optically inaccessible. Such diagnostics advance the measurement state of the art, but even further improvements may come through revamping the standardized tests themselves such as the copper cylinder expansion test. At the core of this modernization, the aforementioned diagnostics play a significant role in revamping and improving the standard test suite for the present era. This research was performed under the auspices of the United States Department of Energy.

  18. Performance Measurement and Accountability in Higher Education: The Puzzle of Qualification Completions

    ERIC Educational Resources Information Center

    Alach, Zhivan

    2016-01-01

    This study explores difficulties in the conceptual positioning of the higher education performance indicator of qualification completion within a standard logic model taken from the public sector performance literature, involving inputs, processes, impacts and outcomes. Organisations are held to be more accountable for the delivery of outputs than…

  19. Fighter pilots' heart rate, heart rate variation and performance during instrument approaches.

    PubMed

    Mansikka, Heikki; Simola, Petteri; Virtanen, Kai; Harris, Don; Oksama, Lauri

    2016-10-01

    Fighter pilots' heart rate (HR), heart rate variation (HRV) and performance during instrument approaches were examined. The subjects were required to fly instrument approaches in a high-fidelity simulator under various levels of task demand. The task demand was manipulated by increasing the load on the subjects by reducing the range at which they commenced the approach. HR and the time domain components of HRV were used as measures of pilot mental workload (PMWL). The findings of this study indicate that HR and HRV are sensitive to varying task demands. HR and HRV were able to distinguish the level of PMWL after which the subjects were no longer able to cope with the increasing task demands and their instrument landing system performance fell to a sub-standard level. The major finding was the HR/HRV's ability to differentiate the sub-standard performance approaches from the high-performance approaches. Practitioner Summary: This paper examined if HR and HRV were sensitive to varying task demands in a fighter aviation environment and if these measures were related to variations in pilot's performance.

  20. Public accountability for health: new standards for health system performance.

    PubMed

    Lansky, D; Purdy, S

    1995-01-01

    This article reviews the failure of contemporary quality oversight organizations to respond to the changing health care environment and suggests an overhaul of quality measurement and assurance functions. The authors examine the factors that have limited public accountability for health care, emphasizing the limited agreement that exists on the purpose of American health care, standards for evaluating care, or the appropriate locus of responsibility for quality of care. A five-part quality oversight system is proposed including development of quality measures, promulgation of national standards, validation and accreditation, use of data for purchasing and provider selection, and use of data for quality improvement.

  1. Welding, V-TECS Guide.

    ERIC Educational Resources Information Center

    Moore, Charles G.; And Others

    This guide provides job-related tasks, performance objectives, performance guides, resources, teaching activities, evaluation standards, and criterion-referenced measures in three units of a welding course. Through the curriculum content of the welding course, the guide helps teachers lead students through the learning process, including the…

  2. 49 CFR Appendix A to Part 223 - Certification of Glazing Materials

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...-ups, test measuring devices, and test procedures were performed by qualified personnel using... following tests: (i) Ballistic Impact in which a standard 22 caliber long rifle lead bullet of 40 grains in... Impact in which a standard 22 caliber long rifle lead bullet of 40 grains in weight impacts at a minimum...

  3. Training and Validation of Standardized Patients for Unannounced Assessment of Physicians' Management of Depression

    ERIC Educational Resources Information Center

    Shirazi, Mandana; Sadeghi, Majid; Emami, A.; Kashani, A. Sabouri; Parikh, Sagar; Alaeddini, F.; Arbabi, Mohammad; Wahlstrom, Rolf

    2011-01-01

    Objective: Standardized patients (SPs) have been developed to measure practitioner performance in actual practice settings, but results have not been fully validated for psychiatric disorders. This study describes the process of creating reliable and valid SPs for unannounced assessment of general-practitioners' management of depression disorders…

  4. Short Shrift to Long Lists: An Alternative Approach to the Development of Performance Standards for School Principals.

    ERIC Educational Resources Information Center

    Louden, William; Wildy, Helen

    1999-01-01

    Describes examples of standards frameworks for principals' work operant in three countries and describes an alternative approach based on interviewing 40 Australian principals. By combining qualitative case studies with probabilistic measurement techniques, the alternative approach provides contextually rich descriptions of growth in performance…

  5. Setting Academic Performance Standards: MCAS vs. PARCC. Policy Brief

    ERIC Educational Resources Information Center

    Phelps, Richard P.

    2015-01-01

    The Massachusetts Comprehensive Assessment System (MCAS) high school test is administered to all Bay State students--both those intending to enroll in college and the many with no such intention. The MCAS high school test is a retrospectively focused standards-based achievement test, designed to measure how well students have mastered the material…

  6. Standardized Tests of Handwriting Readiness: A Systematic Review of the Literature

    ERIC Educational Resources Information Center

    van Hartingsveldt, Margo J.; de Groot, Imelda J. M.; Aarts, Pauline B. M.; Nijhuis-van der Sanden, Maria W. G.

    2011-01-01

    Aim: To establish if there are psychometrically sound standardized tests or test items to assess handwriting readiness in 5- and 6-year-old children on the levels of occupations activities/tasks and performance. Method: Electronic databases were searched to identify measurement instruments. Tests were included in a systematic review if: (1)…

  7. How Principals and Teachers Respond to States' Accountability Systems

    ERIC Educational Resources Information Center

    Lee, Hyemi

    2013-01-01

    Since the 1990s, many states have started implementing standards-based reforms and developed their own accountability systems. Each state established academic content and performance standards, implemented test for all the students in grades 3 through 8 annually, and set up annual measurable objectives in reading and mathematics for districts,…

  8. Steps to standardization and validation of hippocampal volumetry as a biomarker in clinical trials and diagnostic criteria for Alzheimer’s disease

    PubMed Central

    Jack, Clifford R; Barkhof, Frederik; Bernstein, Matt A; Cantillon, Marc; Cole, Patricia E; DeCarli, Charles; Dubois, Bruno; Duchesne, Simon; Fox, Nick C; Frisoni, Giovanni B; Hampel, Harald; Hill, Derek LG; Johnson, Keith; Mangin, Jean-François; Scheltens, Philip; Schwarz, Adam J; Sperling, Reisa; Suhy, Joyce; Thompson, Paul M; Weiner, Michael; Foster, Norman L

    2012-01-01

    Background The promise of Alzheimer’s disease (AD) biomarkers has led to their incorporation in new diagnostic criteria and in therapeutic trials; however, significant barriers exist to widespread use. Chief among these is the lack of internationally accepted standards for quantitative metrics. Hippocampal volumetry is the most widely studied quantitative magnetic resonance imaging (MRI) measure in AD and thus represents the most rational target for an initial effort at standardization. Methods and Results The authors of this position paper propose a path toward this goal. The steps include: 1) Establish and empower an oversight board to manage and assess the effort, 2) Adopt the standardized definition of anatomic hippocampal boundaries on MRI arising from the EADC-ADNI hippocampal harmonization effort as a Reference Standard, 3) Establish a scientifically appropriate, publicly available Reference Standard Dataset based on manual delineation of the hippocampus in an appropriate sample of subjects (ADNI), and 4) Define minimum technical and prognostic performance metrics for validation of new measurement techniques using the Reference Standard Dataset as a benchmark. Conclusions Although manual delineation of the hippocampus is the best available reference standard, practical application of hippocampal volumetry will require automated methods. Our intent is to establish a mechanism for credentialing automated software applications to achieve internationally recognized accuracy and prognostic performance standards that lead to the systematic evaluation and then widespread acceptance and use of hippocampal volumetry. The standardization and assay validation process outlined for hippocampal volumetry is envisioned as a template that could be applied to other imaging biomarkers. PMID:21784356

  9. Improving Gas Furnace Performance: A Field and Laboratory Study at End of Life

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brand, L.; Yee, S.; Baker, J.

    2015-02-01

    In 2010, natural gas provided 54% of total residential space heating energy the U.S. on a source basis, or 3.5 Quadrillion Btu. Natural gas burned in furnaces accounted for 92% of that total, and boilers and other equipment made up the remainder. A better understanding of installed furnace performance is a key to energy savings for this significant energy usage. Natural gas furnace performance can be measured in many ways. The annual fuel utilization efficiency (AFUE) rating provides a fixed value under specified conditions, akin to the EPA miles per gallon rating for new vehicles. The AFUE rating is providedmore » by the manufacturer to the consumer and is a way to choose between models tested on the same basis. This value is commonly used in energy modeling calculations. ASHRAE 103 is a consensus furnace testing standard developed by the engineering community. The procedure provided in the standard covers heat-up, cool down, condensate heat loss, and steady-state conditions and an imposed oversize factor. The procedure can be used to evaluate furnace performance with specified conditions or with some variation chosen by the tester. In this report the ASHRAE 103 test result will be referred to as Annualized Efficiency (AE) to avoid confusion, and any non-standard test conditions will be noted. Aside from these two laboratory tests, steady state or flue loss efficiency can be measured in the field under many conditions; typically as found or tuned to the manufacturers recommended settings. In this report, AE and steady-state efficiency will be used as measures of furnace performance.« less

  10. Performance Evaluation of a PEM Scanner Using the NEMA NU 4—2008 Small Animal PET Standards

    NASA Astrophysics Data System (ADS)

    Luo, Weidong; Anashkin, Edward; Matthews, Christopher G.

    2010-02-01

    The recently published NEMA NU 4-2008 Standards has been specially designed for evaluating the performance of small animal PET scanners used in preclinical applications. In this paper, we report on the NU 4 performance of a clinical positron emission mammography (PEM) system. Since there are no PEM specific performance test protocols available, and the NU 2 protocol (intended for whole-body PET scanners) cannot be applied without modification due to the compact design of the PEM scanner, we decided to evaluate the NU 4 Standards as an alternative. We obtained the following results: Trans-axial spatial resolution 1.8 mm FWHM for high resolution reconstruction mode and 2.4 mm FWHM for standard resolution reconstruction mode with no significant variation within the field of view. The total system sensitivity was 0.16 cps/Bq. In image quality testing, the uniformity was found to be 3.9% STD at the standard resolution mode and 5.6% at the high resolution mode when measured with a 34 mm paddle separation. The NEMA NU 4-2008 Standards were found to be a practicable tool to evaluate the performance of the PEM scanner after some modifications to address the specifics of its detector configuration. Furthermore, the PEM scanner's in-plane spatial resolution was comparable to other small animal PET scanners with good image quality.

  11. Effects of simulated ice on the performance of price type-AA current meter rotors

    USGS Publications Warehouse

    Fulford, Janice M.

    1994-01-01

    Slush ice readily adheres to the standard metal rotor of the winter Price type-AA current meter and affects the ability of the meter to measure the flow velocity accurately. Tests conducted at the U.S. Geological Survey Hydraulics Laboratory at Stennis Space Center, Mississippi, attempt to quantify the effects of slush ice on the performance of standard Price type-AA meter metal rotors. Test data obtained for rotors filled with simulated slush are compared with data for solid-cup polymer and standard hollow-cup metal rotors. Partial filling of the cups only marginally affects rotor performance at velocities greater than 15.24 centimeters per second. However, when cups are filled or over-filled with simulated slush, rotor performance is noticeably affected. Errors associated with slush over-filling and filling of cups are also significant when flows are angled vertically.

  12. Analytical performance, agreement and user-friendliness of six point-of-care testing urine analysers for urinary tract infection in general practice

    PubMed Central

    Schot, Marjolein J C; van Delft, Sanne; Kooijman-Buiting, Antoinette M J; de Wit, Niek J; Hopstaken, Rogier M

    2015-01-01

    Objective Various point-of-care testing (POCT) urine analysers are commercially available for routine urine analysis in general practice. The present study compares analytical performance, agreement and user-friendliness of six different POCT urine analysers for diagnosing urinary tract infection in general practice. Setting All testing procedures were performed at a diagnostic centre for primary care in the Netherlands. Urine samples were collected at four general practices. Primary and secondary outcome measures Analytical performance and agreement of the POCT analysers regarding nitrite, leucocytes and erythrocytes, with the laboratory reference standard, was the primary outcome measure, and analysed by calculating sensitivity, specificity, positive and negative predictive value, and Cohen's κ coefficient for agreement. Secondary outcome measures were the user-friendliness of the POCT analysers, in addition to other characteristics of the analysers. Results The following six POCT analysers were evaluated: Uryxxon Relax (Macherey Nagel), Urisys 1100 (Roche), Clinitek Status (Siemens), Aution 11 (Menarini), Aution Micro (Menarini) and Urilyzer (Analyticon). Analytical performance was good for all analysers. Compared with laboratory reference standards, overall agreement was good, but differed per parameter and per analyser. Concerning the nitrite test, the most important test for clinical practice, all but one showed perfect agreement with the laboratory standard. For leucocytes and erythrocytes specificity was high, but sensitivity was considerably lower. Agreement for leucocytes varied between good to very good, and for the erythrocyte test between fair and good. First-time users indicated that the analysers were easy to use. They expected higher productivity and accuracy when using these analysers in daily practice. Conclusions The overall performance and user-friendliness of all six commercially available POCT urine analysers was sufficient to justify routine use in suspected urinary tract infections in general practice. PMID:25986635

  13. Reverse translated and gold standard continuous performance tests predict global cognitive performance in schizophrenia.

    PubMed

    Bismark, Andrew W; Thomas, Michael L; Tarasenko, Melissa; Shiluk, Alexandra L; Rackelmann, Sonia Y; Young, Jared W; Light, Gregory A

    2018-04-12

    Attentional dysfunction contributes to functional impairments in schizophrenia (SZ). Sustained attention is typically assessed via continuous performance tasks (CPTs), though many CPTs have limited cross-species translational validity and place demands on additional cognitive domains. A reverse-translated 5-Choice Continuous Performance Task (5C-CPT) for human testing-originally developed for use in rodents-was designed to minimize demands on perceptual, visual learning, processing speed, or working memory functions. To-date, no studies have validated the 5C-CPT against gold standard attentional measures nor evaluated how 5C-CPT scores relate to cognition in SZ. Here we examined the relationship between the 5C-CPT and the CPT-Identical Pairs (CPT-IP), an established and psychometrically robust measure of vigilance from the MATRICS Consensus Cognitive Battery (MCCB) in a sample of SZ patients (n = 35). Relationships to global and individual subdomains of cognition were also assessed. 5C-CPT and CPT-IP measures of performance (d-prime) were strongly correlated (r = 0.60). In a regression model, the 5C-CPT and CPT-IP collectively accounted for 54% of the total variance in MCCB total scores, and 27.6% of overall cognitive variance was shared between the 5C-CPT and CPT-IP. These results indicate that the reverse translated 5C-CPT and the gold standard CPT-IP index a common attentional construct that also significantly overlaps with variance in general cognitive performance. The use of simple, cross-species validated behavioral indices of attentional/cognitive functioning such as the 5C-CPT could accelerate the development of novel generalized pro-cognitive therapeutics for SZ and related neuropsychiatric disorders.

  14. 75 FR 63345 - Oil and Gas and Sulphur Operations in the Outer Continental Shelf-Increased Safety Measures for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-14

    ... with a wide range of experts in state and Federal governments, academic institutions, and industry and... measures and performance-based standards recommended in the Safety Measures Report will be analyzed for... government, academic institutions, and industry and advocacy organizations. In addition, draft...

  15. Measuring Effect Sizes: The Effect of Measurement Error. Working Paper 19

    ERIC Educational Resources Information Center

    Boyd, Donald; Grossman, Pamela; Lankford, Hamilton; Loeb, Susanna; Wyckoff, James

    2008-01-01

    Value-added models in education research allow researchers to explore how a wide variety of policies and measured school inputs affect the academic performance of students. Researchers typically quantify the impacts of such interventions in terms of "effect sizes", i.e., the estimated effect of a one standard deviation change in the…

  16. 40 CFR 60.1865 - What are the appropriate units of measurement for reporting my data?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... measurement for reporting my data? 60.1865 Section 60.1865 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emission..., 1999 Model Rule-Reporting § 60.1865 What are the appropriate units of measurement for reporting my data...

  17. Results of the first semi-annual qualification testing of devices to measure breath alcohol

    DOT National Transportation Integrated Search

    1975-01-01

    Eight evidential breath testers were performance tested according to the Standard for Devices to Measure Breath Alcohol Federal Register, Vol 38, No. 212, November 5, 1973. In addition, a prototype breath tester not commercially available was tested....

  18. WOODSTOVE EMISSION MEASUREMENT METHODS COMPARISON AND EMISSION FACTORS UPDATE

    EPA Science Inventory

    This paper compares various field and laboratory woodstove emission measurement methods. n 1988, the U.S. EPA promulgated performance standards for residential wood heaters (woodstoves). ver the past several years, a number of field studies have been undertaken to determine the a...

  19. Measurement Program for Evaluation of Concrete Ties and Fastenings in Transit Track

    DOT National Transportation Integrated Search

    1979-03-01

    This report outlines a measurement program to obtain data on the performance of standard tie designs and associated fastening systems under field service conditions. In addition, the program identifies limited data to be obtained from a wood tie trac...

  20. Creation and Validation of Sintered PTFE BRDF Targets & Standards

    PubMed Central

    Durell, Christopher; Scharpf, Dan; McKee, Greg; L’Heureux, Michelle; Georgiev, Georgi; Obein, Gael; Cooksey, Catherine

    2016-01-01

    Sintered polytetrafluoroethylene (PTFE) is an extremely stable, near-perfect Lambertian reflecting diffuser and calibration standard material that has been used by national labs, space, aerospace and commercial sectors for over two decades. New uncertainty targets of 2 % on-orbit absolute validation in the Earth Observing Systems community have challenged the industry to improve is characterization and knowledge of almost every aspect of radiometric performance (space and ground). Assuming “near perfect” reflectance for angular dependent measurements is no longer going to suffice for many program needs. The total hemispherical spectral reflectance provides a good mark of general performance; but, without the angular characterization of bidirectional reflectance distribution function (BRDF) measurements, critical data is missing from many applications and uncertainty budgets. Therefore, traceable BRDF measurement capability is needed to characterize sintered PTFE’s angular response and provide a full uncertainty profile to users. This paper presents preliminary comparison measurements of the BRDF of sintered PTFE from several laboratories to better quantify the BRDF of sintered PTFE, assess the BRDF measurement comparability between laboratories, and improve estimates of measurement uncertainties under laboratory conditions. PMID:26900206

  1. Creation and Validation of Sintered PTFE BRDF Targets & Standards.

    PubMed

    Durell, Christopher; Scharpf, Dan; McKee, Greg; L'Heureux, Michelle; Georgiev, Georgi; Obein, Gael; Cooksey, Catherine

    2015-09-21

    Sintered polytetrafluoroethylene (PTFE) is an extremely stable, near-perfect Lambertian reflecting diffuser and calibration standard material that has been used by national labs, space, aerospace and commercial sectors for over two decades. New uncertainty targets of 2 % on-orbit absolute validation in the Earth Observing Systems community have challenged the industry to improve is characterization and knowledge of almost every aspect of radiometric performance (space and ground). Assuming "near perfect" reflectance for angular dependent measurements is no longer going to suffice for many program needs. The total hemispherical spectral reflectance provides a good mark of general performance; but, without the angular characterization of bidirectional reflectance distribution function (BRDF) measurements, critical data is missing from many applications and uncertainty budgets. Therefore, traceable BRDF measurement capability is needed to characterize sintered PTFE's angular response and provide a full uncertainty profile to users. This paper presents preliminary comparison measurements of the BRDF of sintered PTFE from several laboratories to better quantify the BRDF of sintered PTFE, assess the BRDF measurement comparability between laboratories, and improve estimates of measurement uncertainties under laboratory conditions.

  2. Narrative performance of gifted African American school-aged children from low-income backgrounds.

    PubMed

    Mills, Monique T

    2015-02-01

    This study investigated classroom differences in the narrative performance of school-age African American English (AAE)-speaking children in gifted and general education classrooms. Forty-three children, Grades 2-5, each generated fictional narratives in response to the book Frog, Where Are You? (Mayer, 1969). Differences in performance on traditional narrative measures (total number of communication units [C-units], number of different words, and mean length of utterance in words) and on AAE production (dialect density measure) between children in gifted and general education classrooms were examined. There were no classroom-based differences in total number of C-units, number of different words, and mean length of utterance in words. Children in gifted education classrooms produced narratives with lower dialect density than did children in general educated classrooms. Direct logistic regression assessed whether narrative dialect density measure scores offered additional information about giftedness beyond scores on the Peabody Picture Vocabulary Test-Fourth Edition (Dunn & Dunn, 2007), a standard measure of language ability. Results indicated that a model with only Peabody Picture Vocabulary Test-Fourth Edition scores best discriminated children in the 2 classrooms. African American children across gifted and general education classrooms produce fictional narratives of similar length, lexical diversity, and syntax complexity. However, African American children in gifted education classrooms may produce lower rates of AAE and perform better on standard measures of vocabulary than those in general education classrooms.

  3. Assessment of human epidermal model LabCyte EPI-MODEL for in vitro skin irritation testing according to European Centre for the Validation of Alternative Methods (ECVAM)-validated protocol.

    PubMed

    Katoh, Masakazu; Hamajima, Fumiyasu; Ogasawara, Takahiro; Hata, Ken-Ichiro

    2009-06-01

    A validation study of an in vitro skin irritation testing method using a reconstructed human skin model has been conducted by the European Centre for the Validation of Alternative Methods (ECVAM), and a protocol using EpiSkin (SkinEthic, France) has been approved. The structural and performance criteria of skin models for testing are defined in the ECVAM Performance Standards announced along with the approval. We have performed several evaluations of the new reconstructed human epidermal model LabCyte EPI-MODEL, and confirmed that it is applicable to skin irritation testing as defined in the ECVAM Performance Standards. We selected 19 materials (nine irritants and ten non-irritants) available in Japan as test chemicals among the 20 reference chemicals described in the ECVAM Performance Standard. A test chemical was applied to the surface of the LabCyte EPI-MODEL for 15 min, after which it was completely removed and the model then post-incubated for 42 hr. Cell v iability was measured by MTT assay and skin irritancy of the test chemical evaluated. In addition, interleukin-1 alpha (IL-1alpha) concentration in the culture supernatant after post-incubation was measured to provide a complementary evaluation of skin irritation. Evaluation of the 19 test chemicals resulted in 79% accuracy, 78% sensitivity and 80% specificity, confirming that the in vitro skin irritancy of the LabCyte EPI-MODEL correlates highly with in vivo skin irritation. These results suggest that LabCyte EPI-MODEL is applicable to the skin irritation testing protocol set out in the ECVAM Performance Standards.

  4. Computerized Maze Navigation and On-Road Performance by Drivers With Dementia

    PubMed Central

    Ott, Brian R.; Festa, Elena K.; Amick, Melissa M.; Grace, Janet; Davis, Jennifer D.; Heindel, William C.

    2012-01-01

    This study examined the ability of computerized maze test performance to predict the road test performance of cognitively impaired and normal older drivers. The authors examined 133 older drivers, including 65 with probable Alzheimer disease, 23 with possible Alzheimer disease, and 45 control subjects without cognitive impairment. Subjects completed 5 computerized maze tasks employing a touch screen and pointer as well as a battery of standard neuropsychological tests. Parameters measured for mazes included errors, planning time, drawing time, and total time. Within 2 weeks, subjects were examined by a professional driving instructor on a standardized road test modeled after the Washington University Road Test. Road test total score was significantly correlated with total time across the 5 mazes. This maze score was significant for both Alzheimer disease subjects and control subjects. One maze in particular, requiring less than 2 minutes to complete, was highly correlated with driving performance. For the standard neuropsychological tests, highest correlations were seen with Trail Making A (TrailsA) and the Hopkins Verbal Learning Tests Trial 1 (HVLT1). Multiple regression models for road test score using stepwise subtraction of maze and neuropsychological test variables revealed significant independent contributions for total maze time, HVLT1, and TrailsA for the entire group; total maze time and HVLT1 for Alzheimer disease subjects; and TrailsA for normal subjects. As a visual analog of driving, a brief computerized test of maze navigation time compares well to standard neuropsychological tests of psychomotor speed, scanning, attention, and working memory as a predictor of driving performance by persons with early Alzheimer disease and normal elders. Measurement of maze task performance appears to be useful in the assessment of older drivers at risk for hazardous driving. PMID:18287166

  5. IFCC approved HPLC reference measurement procedure for the alcohol consumption biomarker carbohydrate-deficient transferrin (CDT): Its validation and use.

    PubMed

    Schellenberg, François; Wielders, Jos; Anton, Raymond; Bianchi, Vincenza; Deenmamode, Jean; Weykamp, Cas; Whitfield, John; Jeppsson, Jan-Olof; Helander, Anders

    2017-02-01

    Carbohydrate-deficient transferrin (CDT) is used as a biomarker of sustained high alcohol consumption. The currently available measurement procedures for CDT are based on various analytical techniques (HPLC, capillary electrophoresis, nephelometry), some differing in the definition of the analyte and using different reference intervals and cut-off values. The Working Group on Standardization of CDT (WG-CDT), initiated by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC), has validated an HPLC candidate reference measurement procedure (cRMP) for CDT (% disialotransferrin to total transferrin based on peak areas), demonstrating that it is suitable as a reference measurement procedure (RMP) for CDT. Presented is a detailed description of the cRMP and its calibration. Practical aspects on how to treat genetic variant and so-called di-tri bridge samples are described. Results of method performance characteristics, as demanded by ISO 15189 and ISO 15193, are given, as well as the reference interval and measurement uncertainty and how to deal with that in routine use. The correlation of the cRMP with commercial CDT procedures and the performance of the cRMP in a network of laboratories are also presented. The performance of the CDT cRMP in combination with previously developed commutable calibrators allows for standardization of the currently available commercial measurement procedures for CDT. The cRMP has recently been approved by the IFCC and will be from now on be known as the IFCC-RMP for CDT, while CDT results standardized according to this RMP should be indicated as CDT IFCC . Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Dosimetric characterization of small fields using a plastic scintillator detector: A large multicenter study.

    PubMed

    Mancosu, Pietro; Pasquino, Massimo; Reggiori, Giacomo; Masi, Laura; Russo, Serenella; Stasi, Michele

    2017-09-01

    In modern radiation therapy accurate small fields dosimetry is a challenge and its standardization is fundamental to harmonize delivered dose in different institutions. This study presents a multicenter characterization of MLC-defined small field for Elekta and Varian linear accelerators. Measurements were performed using the Exradin W1 plastic scintillator detector. The project enrolled 24 Italian centers. Each center performed Tissue Phantom Ratio (TPR), in-plane and cross-plane dose profiles of 0.8×0.8cm 2 field, and Output Factor (OF) measurements for square field sizes ranging from 0.8 to 10cm. Set-up conditions were 10cm depth in water phantom at SSD 90cm. Measurements were performed using two twin Exradin W1 plastic scintillator detectors (PSD) correcting for the Cerenkov effect as proposed by the manufacturer. Data analysis from 12 Varian and 12 Elekta centers was performed. Measurements of 7 centers were not included due to cable problems. TPR measurements showed standard deviations (SD)<1%; SD<0.4mm for the profile penumbra was obtained, while FWHM measurements showed SD<0.5mm. OF measurements showed SD<1.5% for field size greater than 2×2cm 2 . Median OFs values were in agreement with the recent bibliography. High degree of consistency was registered for all the considered parameters. This work confirmed the importance of multicenter dosimetric intercomparison. W1 PSD could be considered as a good candidate for small field measurements. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  7. Other ways of measuring `Big G'

    NASA Astrophysics Data System (ADS)

    Rothleitner, Christian

    2016-03-01

    In 1798, the British scientist Henry Cavendish performed the first laboratory experiment to determine the gravitational force between two massive bodies. From his result, Newton's gravitational constant, G, was calculated. Cavendish's measurement principle was the torsion balance invented by John Michell some 15 years before. During the following two centuries, more than 300 new measurements followed. Although technology - and physics - developed rapidly during this time, surprisingly, most experiments were still based on the same principle. In fact, the most accurate determination of G to date is a measurement based on the torsion balance principle. Despite the fact that G was one of the first fundamental physical constants ever measured, and despite the huge number of experiments performed on it to this day, its CODATA recommended value still has the highest standard measurement uncertainty when compared to other fundamental physical constants. Even more serious is the fact that even measurements based on the same principle often do not overlap within their attributed standard uncertainties. It must be assumed that various experiments are subject to one or more unknown biases. In this talk I will present some alternative experimental setups to the torsion balance which have been performed or proposed to measure G. Although their estimated uncertainties are often higher than most torsion balance experiments, revisiting such ideas is worthwhile. Advances in technology could offer solutions to problems which were previously insurmountable, these solutions could result in lower measurement uncertainties. New measurement principles could also help to uncover hidden systematic effects.

  8. Photovoltaic Performance and Reliability Workshop summary

    NASA Astrophysics Data System (ADS)

    Kroposki, Benjamin

    1997-02-01

    The objective of the Photovoltaic Performance and Reliability Workshop was to provide a forum where the entire photovoltaic (PV) community (manufacturers, researchers, system designers, and customers) could get together and discuss technical issues relating to PV. The workshop included presentations from twenty-five speakers and had more than one hundred attendees. This workshop also included several open sessions in which the audience and speakers could discuss technical subjects in depth. Several major topics were discussed including: PV characterization and measurements, service lifetimes for PV devices, degradation and failure mechanisms for PV devices, standardization of testing procedures, AC module performance and reliability testing, inverter performance and reliability testing, standardization of utility interconnect requirements, experience from field deployed systems, and system certification.

  9. Smartphone assessment of knee flexion compared to radiographic standards.

    PubMed

    Dietz, Matthew J; Sprando, Daniel; Hanselman, Andrew E; Regier, Michael D; Frye, Benjamin M

    2017-03-01

    Measuring knee range of motion (ROM) is an important assessment for the outcomes of total knee arthroplasty. Recent technological advances have led to the development and use of accelerometer-based smartphone applications to measure knee ROM. The purpose of this study was to develop, standardize, and validate methods of utilizing smartphone accelerometer technology compared to radiographic standards, visual estimation, and goniometric evaluation. Participants used visual estimation, a long-arm goniometer, and a smartphone accelerometer to determine range of motion of a cadaveric lower extremity; these results were compared to radiographs taken at the same angles. The optimal smartphone position was determined to be on top of the leg at the distal femur and proximal tibia location. Between methods, it was found that the smartphone and goniometer were comparably reliable in measuring knee flexion (ICC=0.94; 95% CI: 0.91-0.96). Visual estimation was found to be the least reliable method of measurement. The results suggested that the smartphone accelerometer was non-inferior when compared to the other measurement techniques, demonstrated similar deviations from radiographic standards, and did not appear to be influenced by the person performing the measurements or the girth of the extremity. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Smartphone Assessment of Knee Flexion Compared to Radiographic Standards

    PubMed Central

    Dietz, Matthew J.; Sprando, Daniel; Hanselman, Andrew E.; Regier, Michael D.; Frye, Benjamin M.

    2017-01-01

    Purpose Measuring knee range of motion (ROM) is an important assessment for the outcomes of total knee arthroplasty. Recent technological advances have led to the development and use of accelerometer-based smartphone applications to measure knee ROM. The purpose of this study was to develop, standardize, and validate methods of utilizing smartphone accelerometer technology compared to radiographic standards, visual estimation, and goniometric evaluation. Methods Participants used visual estimation, a long-arm goniometer, and a smartphone accelerometer to determine range of motion of a cadaveric lower extremity; these results were compared to radiographs taken at the same angles. Results The optimal smartphone position was determined to be on top of the leg at the distal femur and proximal tibia location. Between methods, it was found that the smartphone and goniometer were comparably reliable in measuring knee flexion (ICC = 0.94; 95% CI: 0.91–0.96). Visual estimation was found to be the least reliable method of measurement. Conclusions The results suggested that the smartphone accelerometer was non-inferior when compared to the other measurement techniques, demonstrated similar deviations from radiographic standards, and did not appear to be influenced by the person performing the measurements or the girth of the extremity. PMID:28179062

  11. 77 FR 16213 - Proposed Information Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-20

    ... ensure that requested data can be provided in the desired format, reporting burden (time and financial... align with upcoming standard performance measure requirements. To separate the currently combined Grant... performance of the functions of the Corporation, including whether the information will have practical utility...

  12. 45 CFR 305.1 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...), ADMINISTRATION FOR CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES PROGRAM PERFORMANCE MEASURES, STANDARDS, FINANCIAL INCENTIVES, AND PENALTIES § 305.1 Definitions. The definitions found in § 301.1 of this... fiscal year means the sum of the State's performance level percentages (determined in accordance with...

  13. Community Level Association between Home Health and Nursing Home Performance on Quality and Hospital 30-day Readmissions for Medicare Patients

    PubMed Central

    Wang, Yun; Pandolfi, Michelle M.; Fine, Jonathan; Metersky, Mark L.; Wang, Changqin; Ho, Shih-Yieh; Galusha, Deron; Nuti, Sudhakar V.; Murugiah, Karthik; Spenard, Ann; Elwell, Timothy; Krumholz, Harlan M.

    2016-01-01

    We evaluated whether community-level home health agencies and nursing home performance is associated with community-level hospital 30-day all-cause risk-standardized readmission rates for Medicare patients used data from the Centers for Medicare & Medicaid Service from 2010 to 2012. Our final sample included 2,855 communities that covered 4,140 hospitals with 6,751,713 patients, 13,060 nursing homes with 1,250,648 residents, and 7,613 home health agencies providing services to 35,660 zipcodes. Based on a mixed effect model, we found that increasing nursing home performance by one star for all of its 4 measures and home health performance by 10 points for all of its 6 measures is associated with decreases of 0.25% (95% CI 0.17–0.34) and 0.60% (95% CI 0.33–0.83), respectively, in community-level risk-standardized readmission rates. PMID:27974869

  14. Cognitive Skills, Student Achievement Tests, and Schools

    PubMed Central

    Finn, Amy S.; Kraft, Matthew A.; West, Martin R.; Leonard, Julia A.; Bish, Crystal E.; Martin, Rebecca E.; Sheridan, Margaret A.; Gabrieli, Christopher F. O.; Gabrieli, John D. E.

    2014-01-01

    Cognitive skills predict academic performance, so schools that improve academic performance might also improve cognitive skills. To investigate the impact schools have on both academic performance and cognitive skills, we related standardized achievement test scores to measures of cognitive skills in a large sample (N=1,367) of 8th-grade students attending traditional, exam, and charter public schools. Test scores and gains in test scores over time correlated with measures of cognitive skills. Despite wide variation in test scores across schools, differences in cognitive skills across schools were negligible after controlling for 4th-grade test scores. Random offers of enrollment to over-subscribed charter schools resulted in positive impacts of such school attendance on math achievement, but had no impact on cognitive skills. These findings suggest that schools that improve standardized achievement tests do so primarily through channels other than cognitive skills. PMID:24434238

  15. Development, implementation, and characterization of a standalone embedded viscosity measurement system based on the impedance spectroscopy of a vibrating wire sensor

    NASA Astrophysics Data System (ADS)

    Santos, José; Janeiro, Fernando M.; Ramos, Pedro M.

    2015-10-01

    This paper presents an embedded liquid viscosity measurement system based on a vibrating wire sensor. Although multiple viscometers based on different working principles are commercially available, there is still a market demand for a dedicated measurement system capable of performing accurate, fast measurements and requiring little or no operator training for simple systems and solution monitoring. The developed embedded system is based on a vibrating wire sensor that works by measuring the impedance response of the sensor, which depends on the viscosity and density of the liquid in which the sensor is immersed. The core of the embedded system is a digital signal processor (DSP) which controls the waveform generation and acquisitions for the measurement of the impedance frequency response. The DSP also processes the acquired waveforms and estimates the liquid viscosity. The user can interact with the measurement system through a keypad and an LCD or through a computer with a USB connection for data logging and processing. The presented system is tested on a set of viscosity standards and the estimated values are compared with the standard manufacturer specified viscosity values. A stability study of the measurement system is also performed.

  16. Conceptual Design Standards for eXternal Visibility System (XVS) Sensor and Display Resolution

    NASA Technical Reports Server (NTRS)

    Bailey, Randall E.; Wilz, Susan J.; Arthur, Jarvis J, III

    2012-01-01

    NASA is investigating eXternal Visibility Systems (XVS) concepts which are a combination of sensor and display technologies designed to achieve an equivalent level of safety and performance to that provided by forward-facing windows in today s subsonic aircraft. This report provides the background for conceptual XVS design standards for display and sensor resolution. XVS resolution requirements were derived from the basis of equivalent performance. Three measures were investigated: a) human vision performance; b) see-and-avoid performance and safety; and c) see-to-follow performance. From these three factors, a minimum but perhaps not sufficient resolution requirement of 60 pixels per degree was shown for human vision equivalence. However, see-and-avoid and see-to-follow performance requirements are nearly double. This report also reviewed historical XVS testing.

  17. Simulation-based Assessment of the Management of Critical Events by Board-certified Anesthesiologists.

    PubMed

    Weinger, Matthew B; Banerjee, Arna; Burden, Amanda R; McIvor, William R; Boulet, John; Cooper, Jeffrey B; Steadman, Randolph; Shotwell, Matthew S; Slagle, Jason M; DeMaria, Samuel; Torsher, Laurence; Sinz, Elizabeth; Levine, Adam I; Rask, John; Davis, Fred; Park, Christine; Gaba, David M

    2017-09-01

    We sought to determine whether mannequin-based simulation can reliably characterize how board-certified anesthesiologists manage simulated medical emergencies. Our primary focus was to identify gaps in performance and to establish psychometric properties of the assessment methods. A total of 263 consenting board-certified anesthesiologists participating in existing simulation-based maintenance of certification courses at one of eight simulation centers were video recorded performing simulated emergency scenarios. Each participated in two 20-min, standardized, high-fidelity simulated medical crisis scenarios, once each as primary anesthesiologist and first responder. Via a Delphi technique, an independent panel of expert anesthesiologists identified critical performance elements for each scenario. Trained, blinded anesthesiologists rated video recordings using standardized rating tools. Measures included the percentage of critical performance elements observed and holistic (one to nine ordinal scale) ratings of participant's technical and nontechnical performance. Raters also judged whether the performance was at a level expected of a board-certified anesthesiologist. Rater reliability for most measures was good. In 284 simulated emergencies, participants were rated as successfully completing 81% (interquartile range, 75 to 90%) of the critical performance elements. The median rating of both technical and nontechnical holistic performance was five, distributed across the nine-point scale. Approximately one-quarter of participants received low holistic ratings (i.e., three or less). Higher-rated performances were associated with younger age but not with previous simulation experience or other individual characteristics. Calling for help was associated with better individual and team performance. Standardized simulation-based assessment identified performance gaps informing opportunities for improvement. If a substantial proportion of experienced anesthesiologists struggle with managing medical emergencies, continuing medical education activities should be reevaluated.

  18. Three-dimensional measurement system for crime scene documentation

    NASA Astrophysics Data System (ADS)

    Adamczyk, Marcin; Hołowko, Elwira; Lech, Krzysztof; Michoński, Jakub; MÄ czkowski, Grzegorz; Bolewicki, Paweł; Januszkiewicz, Kamil; Sitnik, Robert

    2017-10-01

    Three dimensional measurements (such as photogrammetry, Time of Flight, Structure from Motion or Structured Light techniques) are becoming a standard in the crime scene documentation process. The usage of 3D measurement techniques provide an opportunity to prepare more insightful investigation and helps to show every trace in the context of the entire crime scene. In this paper we would like to present a hierarchical, three-dimensional measurement system that is designed for crime scenes documentation process. Our system reflects the actual standards in crime scene documentation process - it is designed to perform measurement in two stages. First stage of documentation, the most general, is prepared with a scanner with relatively low spatial resolution but also big measuring volume - it is used for the whole scene documentation. Second stage is much more detailed: high resolution but smaller size of measuring volume for areas that required more detailed approach. The documentation process is supervised by a specialised application CrimeView3D, that is a software platform for measurements management (connecting with scanners and carrying out measurements, automatic or semi-automatic data registration in the real time) and data visualisation (3D visualisation of documented scenes). It also provides a series of useful tools for forensic technicians: virtual measuring tape, searching for sources of blood spatter, virtual walk on the crime scene and many others. In this paper we present our measuring system and the developed software. We also provide an outcome from research on metrological validation of scanners that was performed according to VDI/VDE standard. We present a CrimeView3D - a software-platform that was developed to manage the crime scene documentation process. We also present an outcome from measurement sessions that were conducted on real crime scenes with cooperation with Technicians from Central Forensic Laboratory of Police.

  19. MULTI-SITE FIELD EVALUATION OF CANDIDATE SAMPLERS FOR MEASURING COARSE-MODE PM

    EPA Science Inventory

    In response to expected changes to the National Ambient Air Quality Standards for particulate matter, comprehensive field studies were conducted to evaluate the performance of sampling methods for measuring coarse mode aerosols (i.e. PMc). Five separate PMc sampling approaches w...

  20. Pilot study comparing changes in postural control after training using a video game balance board program and 2 standard activity-based balance intervention programs.

    PubMed

    Pluchino, Alessandra; Lee, Sae Yong; Asfour, Shihab; Roos, Bernard A; Signorile, Joseph F

    2012-07-01

    To compare the impacts of Tai Chi, a standard balance exercise program, and a video game balance board program on postural control and perceived falls risk. Randomized controlled trial. Research laboratory. Independent seniors (N=40; 72.5±8.40) began the training, 27 completed. Tai Chi, a standard balance exercise program, and a video game balance board program. The following were used as measures: Timed Up & Go, One-Leg Stance, functional reach, Tinetti Performance Oriented Mobility Assessment, force plate center of pressure (COP) and time to boundary, dynamic posturography (DP), Falls Risk for Older People-Community Setting, and Falls Efficacy Scale. No significant differences were seen between groups for any outcome measures at baseline, nor were significant time or group × time differences for any field test or questionnaire. No group × time differences were seen for any COP measures; however, significant time differences were seen for total COP, 3 of 4 anterior/posterior displacement and both velocity, and 1 displacement and 1 velocity medial/lateral measure across time for the entire sample. For DP, significant improvements in the overall score (dynamic movement analysis score), and in 2 of the 3 linear and angular measures were seen for the sample. The video game balance board program, which can be performed at home, was as effective as Tai Chi and the standard balance exercise program in improving postural control and balance dictated by the force plate postural sway and DP measures. This finding may have implications for exercise adherence because the at-home nature of the intervention eliminates many obstacles to exercise training. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

Top