Sample records for performance standards guide

  1. Facility Maintenance. V-TECS Guide.

    ERIC Educational Resources Information Center

    Moore, Charles G.; And Others

    This facility maintenance guide is a compilation of duties, tasks, performance objectives, and performance guides that deals with the psychomotor aspect of an occupation. The guide addresses the three domains of learning: psychomotor, cognitive, and affective. Each unit provides job-relevant tasks, standards of performance, source of standard,…

  2. State Standards and State Assessment Systems: A Guide to Alignment. Series on Standards and Assessments.

    ERIC Educational Resources Information Center

    La Marca, Paul M.; Redfield, Doris; Winter, Phoebe C.

    Alignment of content standards, performance standards, and assessments is crucial. This guide contains information to assist states and districts in aligning their assessment systems to their content and performance standards. It includes a review of current literature, both published and fugitive. The research is woven together with a few basic…

  3. Ornamental Horticulture Production Occupations. Curriculum Guide.

    ERIC Educational Resources Information Center

    Reneau, Fred; And Others

    This curriculum guide contains guidesheets for the ornamental horticulture production occupations. Each guidesheet provides a job-relevant task; performance objective, with task, performance standard, source of standard, and conditions for performance of task; enabling objectives; a list of resources; teaching activities; a criterion-referenced…

  4. Welding, V-TECS Guide.

    ERIC Educational Resources Information Center

    Moore, Charles G.; And Others

    This guide provides job-related tasks, performance objectives, performance guides, resources, teaching activities, evaluation standards, and criterion-referenced measures in three units of a welding course. Through the curriculum content of the welding course, the guide helps teachers lead students through the learning process, including the…

  5. Experiment Design and Analysis Guide - Neutronics & Physics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Misti A Lillo

    2014-06-01

    The purpose of this guide is to provide a consistent, standardized approach to performing neutronics/physics analysis for experiments inserted into the Advanced Test Reactor (ATR). This document provides neutronics/physics analysis guidance to support experiment design and analysis needs for experiments irradiated in the ATR. This guide addresses neutronics/physics analysis in support of experiment design, experiment safety, and experiment program objectives and goals. The intent of this guide is to provide a standardized approach for performing typical neutronics/physics analyses. Deviation from this guide is allowed provided that neutronics/physics analysis details are properly documented in an analysis report.

  6. Intelligence Level Performance Standards Research for Autonomous Vehicles

    PubMed Central

    Bostelman, Roger B.; Hong, Tsai H.; Messina, Elena

    2017-01-01

    United States and European safety standards have evolved to protect workers near Automatic Guided Vehicles (AGV’s). However, performance standards for AGV’s and mobile robots have only recently begun development. Lessons can be learned from research and standards efforts for mobile robots applied to emergency response and military applications. Research challenges, tests and evaluations, and programs to develop higher intelligence levels for vehicles can also used to guide industrial AGV developments towards more adaptable and intelligent systems. These other efforts also provide useful standards development criteria for AGV performance test methods. Current standards areas being considered for AGVs are for docking, navigation, obstacle avoidance, and the ground truth systems that measure performance. This paper provides a look to the future with standards developments in both the performance of vehicles and the dynamic perception systems that measure intelligent vehicle performance. PMID:28649189

  7. Intelligence Level Performance Standards Research for Autonomous Vehicles.

    PubMed

    Bostelman, Roger B; Hong, Tsai H; Messina, Elena

    2015-01-01

    United States and European safety standards have evolved to protect workers near Automatic Guided Vehicles (AGV's). However, performance standards for AGV's and mobile robots have only recently begun development. Lessons can be learned from research and standards efforts for mobile robots applied to emergency response and military applications. Research challenges, tests and evaluations, and programs to develop higher intelligence levels for vehicles can also used to guide industrial AGV developments towards more adaptable and intelligent systems. These other efforts also provide useful standards development criteria for AGV performance test methods. Current standards areas being considered for AGVs are for docking, navigation, obstacle avoidance, and the ground truth systems that measure performance. This paper provides a look to the future with standards developments in both the performance of vehicles and the dynamic perception systems that measure intelligent vehicle performance.

  8. A Catalog of Performance Objectives and Performance Guides for Laser Systems Technician for the Job Titles of Laser Technician D.O.T. 019.181-010, Laser Systems Technician D.O.T.-N/A.

    ERIC Educational Resources Information Center

    Pennsylvania State Dept. of Education, Harrisburg. Bureau of Vocational and Technical Education.

    This catalog lists and describes the tasks performed by a laser technician and standards for their performance. Each duty contains performance objectives for related tasks. Included in the objectives are standards that must be met and conditions for performance of the tasks. Performance guides provided for each objective identify the conditions…

  9. Ohio's Resource Guide for Voluntary Skill Standards.

    ERIC Educational Resources Information Center

    Springfield-Clark Joint Vocational School, Springfield, OH.

    Voluntary skill standards are industry-based, industry-verified performance specifications that identify the knowledge, skills, and abilities individuals need for success in an industry. This resource guide is designed to raise awareness of voluntary skill standards, identify their benefits, and encourage stakeholder involvement in implementation…

  10. ARES (Automated Residential Energy Standard) 1.2: User`s guide, in support of proposed interim energy conservation voluntary performance standards for new non-federal residential buildings: Volume 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The ARES (Automated Residential Energy Standard) User`s Guide is designed to the user successfully operate the ARES computer program. This guide assumes that the user is familiar with basic PC skills such as using a keyboard and loading a disk drive. The ARES computer program was designed to assist building code officials in creating a residential energy standard based on local climate and costs.

  11. V-TECS Guide for Automobile Air Conditioning and Electrical System Technician.

    ERIC Educational Resources Information Center

    Meyer, Calvin F.; Benson, Robert T.

    This curriculum guide provides an outline for an eight-unit course to train automobile air conditioning and electrical system technicians. Each unit focuses on a duty that is composed of a number of performance objectives. For each objective, these materials are provided: a task, a standard of performance of task, source of standard, conditions…

  12. V-TECS Guide for Commercial Foods.

    ERIC Educational Resources Information Center

    Elliott, Ronald T.; Benson, Robert T.

    This guide is designed to provide job-relevant tasks, performance objectives, performance guides, resources, teaching activities, evaluation standards, and achievement testing for commercial foods occupations. It can be used with any teaching method, and it addresses all three domains of learning: psychomotor, cognitive, and affective. The guide…

  13. A Catalog of Performance Objectives, Performance Conditions, and Performance Guides for Machine Tool Operations.

    ERIC Educational Resources Information Center

    Stadt, Ronald; And Others

    This catalog provides performance objectives, tasks, standards, and performance guides associated with current occupational information relating to the job content of machinists, specifically tool grinder operators, production lathe operators, and production screw machine operators. The catalog is comprised of 262 performance objectives, tool and…

  14. Environmental Control System Installer/Servicer (Residential Air Conditioning Mechanic). V-TECS Guide.

    ERIC Educational Resources Information Center

    Meyer, Calvin F.; Benson, Robert T.

    This guide provides job relevant tasks, performance objectives, performance guides, resources, learning activitites, evaluation standards, and achievement testing in the occupation of environmental control system installer/servicer (residential air conditioning mechanic). It is designed to be used with any chosen teaching method. The course…

  15. Laser System Technician. A Catalog of Performance Objectives and Performance Guides.

    ERIC Educational Resources Information Center

    Florida State Dept. of Education, Tallahassee. Div. of Vocational, Adult, and Community Education.

    This Vocational-Technical Education Consortium of States (V-TECS) catalog contains the state-of-the-art tasks and standards of performance for the occupation of laser system technician. It provides the curriculum specialist or instructor with the foundation for instructional development. Performance objectives and performance guides are provided…

  16. Curriculum Based Functional Vocational Assessment Guide. Correlation of the Life Centered Career Education Curriculum with Specific Occupational Programs, Standards of Work Performance, and Campus Assessment Instruments.

    ERIC Educational Resources Information Center

    Quinones, William A.

    This document is a guide developed for the Dallas Independent School District's (DISD's) Multiple Careers Magnet Center, which provides special education students with training in standards of work performance and specific occupational skills for successful transition to community life and employment. The document also provides information for…

  17. Standardization Documents

    DTIC Science & Technology

    2011-08-01

    Specifications and Standards; Guide Specifications; CIDs; and NGSs . Learn. Perform. Succeed. STANDARDIZATION DOCUMENTS Federal Specifications Commercial...national or international standardization document developed by a private sector association, organization, or technical society that plans ...Maintain lessons learned • Examples: Guidance for application of a technology; Lists of options Learn. Perform. Succeed. DEFENSE HANDBOOK

  18. Student Performance Standards for Senior High Language Arts.

    ERIC Educational Resources Information Center

    Brevard County School Board, Cocoa, FL.

    Developed by a team of 13 teachers, this guide presents student performance standards for 36 high school language arts courses. For each course described, performance standards and intended outcomes are preceded by a curriculum framework that includes a statement of major concepts and content, laboratory activities, special notes, and intended…

  19. Basic Commercial Art. Florida Vocational Program Guide.

    ERIC Educational Resources Information Center

    University of South Florida, Tampa. Dept. of Adult and Vocational Education.

    This document includes a vocational program guide and Career Merit Achievement Plan (Career MAP) for secondary and postsecondary basic commercial art programs. The guide contains the following sections: occupational description; program content (curriculum framework and student performance standards); program implementation (student admission…

  20. Commercial Art. Florida Vocational Program Guide.

    ERIC Educational Resources Information Center

    University of South Florida, Tampa. Dept. of Adult and Vocational Education.

    This document contains a vocational program guide and Career Merit Achievement Plan (Career MAP) for secondary and postsecondary commercial art. The guide contains the following sections: occupational description; program content (curriculum framework and student performance standards); program implementation (student admission criteria,…

  1. Emergency coronary angioplasty with stenting using Cordis® diagnostic coronary catheters when there is difficulty in engaging guide catheters and bench evaluation of diagnostic and guide catheters.

    PubMed

    Arokiaraj, Mark Christopher

    2018-02-01

    Difficulty in engaging with guide catheters is not uncommon in acute emergencies. We aimed to evaluate the use of Cordis ® INFINITI diagnostic catheters to perform angioplasty in patients in whom the coronaries cannot be engaged using standard guide catheters. In 34 cases of acute coronary syndrome, when difficulty in engagement with two standard guide catheters was encountered with reasonable manipulations, angioplasty was performed using diagnostic catheters. In total, 40 stents were placed by this technique. Pushability and trackability, distal tip flexion and three-point bending tests were performed to evaluate the performance of the guide and diagnostic catheters. Angioplasty was performed easily in a setting where it would have been very difficult to perform. Coronary dissection occurred in one patient, treated by a stent. The stent and dilatation balloons were easily passed through the diagnostic catheters. Pressure tracings were clearly preserved with certain stent delivery systems, and at angioplasty, although there was slightly reduced opacification of the respective artery, the coronary anatomy was sufficiently visualized to perform angioplasty. No periprocedural target lesion complications were seen in any cases. Pushability and trackability tests showed good force transmission along a tortuous path with diagnostic catheters, and balanced force-displacement curves from three-point bending tests and distal tip softness tests. Angioplasty with stenting can be performed safely through 6F Cordis ® infiniti diagnostic catheters when difficulty in engaging guide catheters is encountered. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Use of Low-Fidelity Simulation Laboratory Training for Teaching Radiology Residents CT-Guided Procedures.

    PubMed

    Picard, Melissa; Nelson, Rachel; Roebel, John; Collins, Heather; Anderson, M Bret

    2016-11-01

    To determine the benefit of the addition of low-fidelity simulation-based training to the standard didactic-based training in teaching radiology residents common CT-guided procedures. This was a prospective study involving 24 radiology residents across all years in a university program. All residents underwent standard didactic lecture followed by low-fidelity simulation-based training on three common CT-guided procedures: random liver biopsy, lung nodule biopsy, and drain placement. Baseline knowledge, confidence, and performance assessments were obtained after the didactic session and before the simulation training session. Approximately 2 months later, all residents participated in a simulation-based training session covering all three of these procedures. Knowledge, confidence, and performance data were obtained afterward. These assessments covered topics related to preprocedure workup, intraprocedure steps, and postprocedure management. Knowledge data were collected based on a 15-question assessment. Confidence data were obtained based on a 5-point Likert-like scale. Performance data were obtained based on successful completion of predefined critical steps. There was significant improvement in knowledge (P = .005), confidence (P < .008), and tested performance (P < .043) after the addition of simulation-based training to the standard didactic curriculum for all procedures. This study suggests that the addition of low-fidelity simulation-based training to a standard didactic-based curriculum is beneficial in improving resident knowledge, confidence, and tested performance of common CT-guided procedures. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  3. Hospitality Management. Florida Vocational Program Guide.

    ERIC Educational Resources Information Center

    Florida State Univ., Tallahassee. Center for Instructional Development and Services.

    This program guide is intended for the implementation of a hospitality management program in Florida secondary and postsecondary schools. The program guide describes the program content and structure, provides a program description, describes jobs under the program, and includes a curriculum framework and student performance standards for…

  4. Guide Specification For Water/Foam Aircraft Rescue and Firefighting Vehicles

    DOT National Transportation Integrated Search

    2002-02-18

    This advisory circular (AC) contains performance standards, specifications, and : recommendations for the design, construction, and testing of a family of : aircraft rescue and fire fighting (ARFF) vehicles. The guide specifications : covers two clas...

  5. Recommendations for fluorescence instrument qualification: the new ASTM Standard Guide.

    PubMed

    DeRose, Paul C; Resch-Genger, Ute

    2010-03-01

    Aimed at improving quality assurance and quantitation for modern fluorescence techniques, ASTM International (ASTM) is about to release a Standard Guide for Fluorescence, reviewed here. The guide's main focus is on steady state fluorometry, for which available standards and instrument characterization procedures are discussed along with their purpose, suitability, and general instructions for use. These include the most relevant instrument properties needing qualification, such as linearity and spectral responsivity of the detection system, spectral irradiance reaching the sample, wavelength accuracy, sensitivity or limit of detection for an analyte, and day-to-day performance verification. With proper consideration of method-inherent requirements and limitations, many of these procedures and standards can be adapted to other fluorescence techniques. In addition, procedures for the determination of other relevant fluorometric quantities including fluorescence quantum yields and fluorescence lifetimes are briefly introduced. The guide is a clear and concise reference geared for users of fluorescence instrumentation at all levels of experience and is intended to aid in the ongoing standardization of fluorescence measurements.

  6. Vocational and Technical Education Performance Standards and Competencies.

    ERIC Educational Resources Information Center

    Connecticut State Board of Education, Hartford.

    These Connecticut vocational and technical performance standards and competencies are a guide for overall quality attainment in these seven vocational and technical program areas: agricultural science technology education; business and finance technology education; cooperative work education; family and consumer sciences education; marketing…

  7. Municipal Solid Waste Landfill New Source Performance Standards (NSPS) and Emission Guidelines (EG) -- Questions and Answers

    EPA Pesticide Factsheets

    This November 1998 document of questions and answers are provided as a guide for those subject to the new source performance standards (NSPS) or emission guidelines (EG), as well as those implementing the NSPS or EG.

  8. Probability of Failure Analysis Standards and Guidelines for Expendable Launch Vehicles

    NASA Astrophysics Data System (ADS)

    Wilde, Paul D.; Morse, Elisabeth L.; Rosati, Paul; Cather, Corey

    2013-09-01

    Recognizing the central importance of probability of failure estimates to ensuring public safety for launches, the Federal Aviation Administration (FAA), Office of Commercial Space Transportation (AST), the National Aeronautics and Space Administration (NASA), and U.S. Air Force (USAF), through the Common Standards Working Group (CSWG), developed a guide for conducting valid probability of failure (POF) analyses for expendable launch vehicles (ELV), with an emphasis on POF analysis for new ELVs. A probability of failure analysis for an ELV produces estimates of the likelihood of occurrence of potentially hazardous events, which are critical inputs to launch risk analysis of debris, toxic, or explosive hazards. This guide is intended to document a framework for POF analyses commonly accepted in the US, and should be useful to anyone who performs or evaluates launch risk analyses for new ELVs. The CSWG guidelines provide performance standards and definitions of key terms, and are being revised to address allocation to flight times and vehicle response modes. The POF performance standard allows a launch operator to employ alternative, potentially innovative methodologies so long as the results satisfy the performance standard. Current POF analysis practice at US ranges includes multiple methodologies described in the guidelines as accepted methods, but not necessarily the only methods available to demonstrate compliance with the performance standard. The guidelines include illustrative examples for each POF analysis method, which are intended to illustrate an acceptable level of fidelity for ELV POF analyses used to ensure public safety. The focus is on providing guiding principles rather than "recipe lists." Independent reviews of these guidelines were performed to assess their logic, completeness, accuracy, self- consistency, consistency with risk analysis practices, use of available information, and ease of applicability. The independent reviews confirmed the general validity of the performance standard approach and suggested potential updates to improve the accuracy each of the example methods, especially to address reliability growth.

  9. Illinois Occupational Skill Standards: Nursing Cluster.

    ERIC Educational Resources Information Center

    Illinois Occupational Skill Standards and Credentialing Council, Carbondale.

    These skill standards, developed through a consortium of educational and industry partners in Illinois, serve as guides to workforce preparation program providers to define content for their programs and to employers to establish the skills and standards necessary for job acquisition and performance. The skill standards include the following…

  10. 75 FR 27288 - New Performance Standards for Salmonella and Campylobacter in Young Chicken and Turkey Slaughter...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-14

    ... DEPARTMENT OF AGRICULTURE Food Safety and Inspection Service [Docket No. FSIS-2009-0034] New...; New Compliance Guides AGENCY: Food Safety and Inspection Service, USDA. ACTION: Notice. SUMMARY: The Food Safety and Inspection Service (FSIS) is announcing new performance standards for the pathogenic...

  11. A Guide to Just and Fair Remediation of Counseling Students with Professional Performance Deficiencies

    ERIC Educational Resources Information Center

    McAdams, Charles R.; Foster, Victoria A.

    2007-01-01

    Ethical standards for counselor training require remediation of students with professional performance deficiencies. However, standards fail to specify the type or extent of remediation necessary to safeguard students' legal rights or justify dismissal if remediation is unsuccessful. Critical assessment of remedial practices in counselor…

  12. Illinois Occupational Skill Standards: Physical Therapist Assistant Cluster.

    ERIC Educational Resources Information Center

    Illinois Occupational Skill Standards and Credentialing Council, Carbondale.

    These skill standards, developed through a consortium of educational and industry partners in Illinois, serve as guides to workforce preparation program providers to define content for their programs and to employers to establish the skills and standards necessary for job acquisition and performance. The skill standards include the following…

  13. Illinois Occupational Skill Standards: Medical Office Cluster.

    ERIC Educational Resources Information Center

    Illinois Occupational Skill Standards and Credentialing Council, Carbondale.

    These skill standards, developed through a consortium of educational and industry partners in Illinois, serve as guides to workforce preparation program providers to define content for their programs and to employers to establish the skills and standards necessary for job acquisition and performance. The skill standards include the following…

  14. Illinois Occupational Skill Standards: Press Operations Cluster.

    ERIC Educational Resources Information Center

    Illinois Occupational Skill Standards and Credentialing Council, Carbondale.

    These skill standards, developed through a consortium of educational and industry partners in Illinois, serve as guides to workforce preparation program providers to define content for their programs and to employers to establish the skills and standards necessary for job acquisition and performance. The skill standards include the following…

  15. Illinois Occupational Skill Standards: Retail Garden Center Cluster.

    ERIC Educational Resources Information Center

    Illinois Occupational Skill Standards and Credentialing Council, Carbondale.

    These skill standards, developed through a consortium of educational and industry partners in Illinois, serve as guides to workforce preparation program providers to define content for their programs and to employers to establish the skills and standards necessary for job acquisition and performance. The skill standards include the following…

  16. South Carolina Guide for Selling.

    ERIC Educational Resources Information Center

    Elliott, Ronald T.

    This curriculum guide provides materials for a secondary course in salesmanship. It contains 6 units that cover 33 competencies. Each competency is presented in a standard format: performance objective, resources, teaching activities, evaluation, and supplementary materials, including an information sheet, exercises, and checklists. Units and…

  17. Transthoracic ultrasound guided balloon dilation of cor triatriatum dexter in 2 Rottweiler puppies.

    PubMed

    Birettoni, F; Caivano, D; Bufalari, A; Giorgi, M E; Miglio, A; Paradies, P; Porciello, F

    2016-12-01

    Balloon dilation was performed in two Rottweiler puppies with cor triatriatum dexter and clinical signs of ascites using transthoracic echocardiographic guidance. The dogs were positioned on a standard echocardiography table in right lateral recumbency, and guide wires and balloon catheters were imaged by echocardiographic views optimized to allow visualization of the defect. The procedures were performed successfully without complications and clinical signs were resolved completely in both cases. Guide wires and balloon catheters appeared hyperechoic on transthoracic echocardiography image and could be clearly monitored and guided in real-time. These two cases demonstrate that it is possible to perform balloon catheter dilation of cor triatriatum dexter under transthoracic guidance alone. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Reductions in the variations of respiration signals for respiratory-gated radiotherapy when using the video-coaching respiration guiding system

    NASA Astrophysics Data System (ADS)

    Lee, Hyun Jeong; Yea, Ji Woon; Oh, Se An

    2015-07-01

    Respiratory-gated radiation therapy (RGRT) has been used to minimize the dose to normal tissue in lung-cancer radiotherapy. The present research aims to improve the regularity of respiration in RGRT by using a video-coached respiration guiding system. In the study, 16 patients with lung cancer were evaluated. The respiration signals of the patients were measured by using a realtime position management (RPM) respiratory gating system (Varian, USA), and the patients were trained using the video-coaching respiration guiding system. The patients performed free breathing and guided breathing, and the respiratory cycles were acquired for ~5 min. Then, Microsoft Excel 2010 software was used to calculate the mean and the standard deviation for each phase. The standard deviation was computed in order to analyze the improvement in the respiratory regularity with respect to the period and the displacement. The standard deviation of the guided breathing decreased to 48.8% in the inhale peak and 24.2% in the exhale peak compared with the values for the free breathing of patient 6. The standard deviation of the respiratory cycle was found to be decreased when using the respiratory guiding system. The respiratory regularity was significantly improved when using the video-coaching respiration guiding system. Therefore, the system is useful for improving the accuracy and the efficiency of RGRT.

  19. P21 Common Core Toolkit: A Guide to Aligning the Common Core State Standards with the Framework for 21st Century Skills

    ERIC Educational Resources Information Center

    Partnership for 21st Century Skills, 2011

    2011-01-01

    Standards drive critical elements of the American educational system--the curricula that schools follow, the textbooks students read, and the tests they take. Similarly, standards establish the levels of performance that students, teachers and schools are expected to meet. To succeed in the 21st century, all students will need to perform to high…

  20. The Complete Guide to Training Delivery: A Competency-Based Approach.

    ERIC Educational Resources Information Center

    King, Stephen B.; King, Marsha; Rothwell, William J.

    This guide focuses on 14 instructor competencies identified by the International Board of Standards for Training, Performance, and Instruction. It provides examples, job aids, worksheets, case studies, and sample dialogs and contains actual experiences and critical incidents faced by trainers who participated in the survey study. Strategies to…

  1. Choosing an Optical Disc System: A Guide for Users and Resellers.

    ERIC Educational Resources Information Center

    Vane-Tempest, Stewart

    1995-01-01

    Presents a guide for selecting an optional disc system. Highlights include storage hierarchy; standards; data life cycles; security; implementing an optical jukebox system; optimizing the system; performance; quality and reliability; software; cost of online versus near-line; and growing opportunities. Sidebars provide additional information on…

  2. Efficacy of ultrasound-guided thoracentesis catheter drainage for pleural effusion

    PubMed Central

    Cao, Weitian; Wang, Yi; Zhou, Ningming; Xu, Bing

    2016-01-01

    The factors influencing the efficacy of ultrasound-guided thoracentesis catheter drainage were investigated in the present study. A retrospective analysis of clinical data from 435 patients who presented with a pleural effusion was performed. Patients were divided into a control group and an intervention group. Thirty-seven patients in the control group were given standard care using pleural puncture to draw the excess fluid. The 398 patients in the intervention group were treated using ultrasound-guided thoracentesis catheter drainage. The rate of successful drainage of a pleural effusion was significantly higher (P<0.05), while the rate of complication was lower, in the ultrasound-guided thoracentesis cases compared to standard care treatment. In conclusion, ultrasound-guided thoracentesis catheter drainage is an efficient, safe and minimally invasive procedure to alleviate pleural effusion. The efficacy of the procedure is related to the separation of pleural effusion, drainage tube type and tube diameter. PMID:28105155

  3. Cost Effectiveness of Genotype-Guided Warfarin Dosing in Patients with Mechanical Heart Valve Replacement Under the Fee-for-Service System.

    PubMed

    Kim, Dong-Jin; Kim, Ho-Sook; Oh, Minkyung; Kim, Eun-Young; Shin, Jae-Gook

    2017-10-01

    Although studies assessing the cost effectiveness of genotype-guided warfarin dosing for the management of atrial fibrillation, deep vein thrombosis, and pulmonary embolism have been reported, no publications have addressed genotype-guided warfarin therapy in mechanical heart valve replacement (MHVR) patients or genotype-guided warfarin therapy under the fee-for-service (FFS) insurance system. The aim of this study was to evaluate the cost effectiveness of genotype-guided warfarin dosing in patients with MHVR under the FFS system from the Korea healthcare sector perspective. A decision-analytic Markov model was developed to evaluate the cost effectiveness of genotype-guided warfarin dosing compared with standard dosing. Estimates of clinical adverse event rates and health state utilities were derived from the published literature. The outcome measure was the incremental cost-effectiveness ratio (ICER) per quality-adjusted life-year (QALY). One-way and probabilistic sensitivity analyses were performed to explore the range of plausible results. In a base-case analysis, genotype-guided warfarin dosing was associated with marginally higher QALYs than standard warfarin dosing (6.088 vs. 6.083, respectively), at a slightly higher cost (US$6.8) (year 2016 values). The ICER was US$1356.2 per QALY gained. In probabilistic sensitivity analysis, there was an 82.7% probability that genotype-guided dosing was dominant compared with standard dosing, and a 99.8% probability that it was cost effective at a willingness-to-pay threshold of US$50,000 per QALY gained. Compared with only standard warfarin therapy, genotype-guided warfarin dosing was cost effective in MHVR patients under the FFS insurance system.

  4. A lack of standardization: the basis for the ethical issues surrounding quality and performance reports.

    PubMed

    Suchy, Kirsten

    2010-01-01

    Consumers in the United States are taking advantage of the proliferation of publicly available, internet-based performance reports and quality appraisals of health plans, healthcare organizations, hospitals, and physicians to aid in their healthcare decision making. However, these appraisal practices have given rise to controversy and debate over certain distinctive ethical issues. This article advocates a standardized ethical framework to guide current and future development and implementation of performance reports. This framework, which would resolve a number of the major issues, includes the following ethical principles to guide the practice of public reporting on the Internet and facilitate enhanced quality improvement in the healthcare industry: legitimacy, data integrity and quality, transparency, informed understanding, equity, privacy and confidentiality, collaboration, accountability, and evaluation and continuous improvement.

  5. Wisconsin's Model Academic Standards for Marketing Education. Bulletin No. 9005.

    ERIC Educational Resources Information Center

    Wisconsin State Dept. of Public Instruction, Madison.

    This document contains standards for the academic content of the Wisconsin K-12 curriculum in the area of marketing education. Developed by task forces of educators, parents, board of education members, and employers and employees, the standards cover content, performance, and proficiency areas. The first part of the guide is an introduction that…

  6. Aerospace Technology Curriculum Guide. Invest in Success. Vo. Ed. #260.

    ERIC Educational Resources Information Center

    Idaho State Dept. of Education, Boise. Div. of Vocational Education.

    This document contains standards for an articulated secondary and postsecondary curriculum in aerospace technology. The curriculum standards can be used to ensure that vocational programs meet the needs of local business and industry. The first part of the document contains a task list and student performance standards for the aerospace technology…

  7. Objective assessment of operator performance during ultrasound-guided procedures.

    PubMed

    Tabriz, David M; Street, Mandie; Pilgram, Thomas K; Duncan, James R

    2011-09-01

    Simulation permits objective assessment of operator performance in a controlled and safe environment. Image-guided procedures often require accurate needle placement, and we designed a system to monitor how ultrasound guidance is used to monitor needle advancement toward a target. The results were correlated with other estimates of operator skill. The simulator consisted of a tissue phantom, ultrasound unit, and electromagnetic tracking system. Operators were asked to guide a needle toward a visible point target. Performance was video-recorded and synchronized with the electromagnetic tracking data. A series of algorithms based on motor control theory and human information processing were used to convert raw tracking data into different performance indices. Scoring algorithms converted the tracking data into efficiency, quality, task difficulty, and targeting scores that were aggregated to create performance indices. After initial feasibility testing, a standardized assessment was developed. Operators (N = 12) with a broad spectrum of skill and experience were enrolled and tested. Overall scores were based on performance during ten simulated procedures. Prior clinical experience was used to independently estimate operator skill. When summed, the performance indices correlated well with estimated skill. Operators with minimal or no prior experience scored markedly lower than experienced operators. The overall score tended to increase according to operator's clinical experience. Operator experience was linked to decreased variation in multiple aspects of performance. The aggregated results of multiple trials provided the best correlation between estimated skill and performance. A metric for the operator's ability to maintain the needle aimed at the target discriminated between operators with different levels of experience. This study used a highly focused task model, standardized assessment, and objective data analysis to assess performance during simulated ultrasound-guided needle placement. The performance indices were closely related to operator experience.

  8. Agribusiness Management. Competency Based Education Curriculum. Teacher's Guide.

    ERIC Educational Resources Information Center

    Long, Diana

    This publication is the Teacher's Guide for the competency based curriculum in agribusiness management for high school students in West Virginia. The purpose of the competency based education curriculum is to provide a set of West Virginia-validated agribusiness tasks, along with the steps needed to perform each task, the evaluation standards, and…

  9. Aerobic Digestion. Biological Treatment Process Control. Instructor's Guide.

    ERIC Educational Resources Information Center

    Klopping, Paul H.

    This unit on aerobic sludge digestion covers the theory of the process, system components, factors that affect the process performance, standard operational concerns, indicators of steady-state operations, and operational problems. The instructor's guide includes: (1) an overview of the unit; (2) lesson plan; (3) lecture outline (keyed to a set of…

  10. Emergency Medical Technician-Ambulance: National Standard Curriculum. Course Guide (Third Edition).

    ERIC Educational Resources Information Center

    National Highway Traffic Safety Administration (DOT), Washington, DC.

    This course guide is intended to assist course coordinators in planning and managing a course to train emergency medical technicians to work with ambulance or other specialized rescue services. Materials are presented to enable students to perform the following functions: recognize the nature and seriousness of the patient's condition or extent of…

  11. Nutriendo la Promesa: Materiales Para la Aplicacion de las Normas de Ejecucion del Programa Head Start. Guia Para la Utilizacion de los Materiales [y] Transparencias (Nurturing the Promise: Set of Training Materials on the Head Start Program Performance Standards. User's Guide [and] Set of Transparencies).

    ERIC Educational Resources Information Center

    Educational Services, Inc., Washington, DC.

    Since 1975, the Head Start Program Performance Standards have defined the services that local programs are required to provide to enrolled children and families. With revisions effective in 1998, the Program Performance Standards translate the Head Start vision into quality practices implemented at the local level. This document is comprised of a…

  12. A Multicenter comparative trial of a novel EUS-guided core biopsy needle (SharkCore™) with the 22-gauge needle in patients with solid pancreatic mass lesions

    PubMed Central

    Naveed, Mariam; Siddiqui, Ali A.; Kowalski, Thomas E.; Loren, David E.; Khalid, Ammara; Soomro, Ayesha; Mazhar, Syed M.; Yoo, Joseph; Hasan, Raza; Yalamanchili, Silpa; Tarangelo, Nicholas; Taylor, Linda J.; Adler, Douglas G.

    2018-01-01

    Background and Objectives: The ability to obtain adequate tissue of solid pancreatic lesions by EUS-guided remains a challenge. The aim of this study was to compare the performance characteristics and safety of EUS-FNA for evaluating solid pancreatic lesions using the standard 22-gauge needle versus a novel EUS biopsy needle. Methods: This was a multicenter retrospective study of EUS-guided sampling of solid pancreatic lesions between 2009 and 2015. Patients underwent EUS-guided sampling with a 22-gauge SharkCore (SC) needle or a standard 22-gauge FNA needle. Technical success, performance characteristics of EUS-FNA, the number of needle passes required to obtain a diagnosis, diagnostic accuracy, and complications were compared. Results: A total of 1088 patients (mean age = 66 years; 49% female) with pancreatic masses underwent EUS-guided sampling with a 22-gauge SC needle (n = 115) or a standard 22-gauge FNA needle (n = 973). Technical success was 100%. The frequency of obtaining an adequate cytology by EUS-FNA was similar when using the SC and the standard needle (94.1% vs. 92.7%, respectively). The sensitivity, specificity, and diagnostic accuracy of EUS-FNA for tissue diagnosis were not significantly different between two needles. Adequate sample collection leading to a definite diagnosis was achieved by the 1st, 2nd, and 3rd pass in 73%, 92%, and 98% of procedures using the SC needle and 20%, 37%, and 94% procedures using the standard needle (P < 0.001), respectively. The median number of passes to obtain a tissue diagnosis using the SC needle was significantly less as compared to the standard needle (1 and 3, respectively; P < 0.001). Conclusions: The EUS SC biopsy needle is safe and technically feasible for EUS-FNA of solid pancreatic mass lesions. Preliminary results suggest that the SC needle has a diagnostic yield similar to the standard EUS needle and significantly reduces the number of needle passes required to obtain a tissue diagnosis. PMID:29451167

  13. The National Shipbuilding Research Program: Contaminated Sediment Management Guide for NSRP Shipyards. Appendix 4: Removal Technologies

    DTIC Science & Technology

    1999-10-22

    la performance technique et environnementale de PAmphibex Journal: Report for Environment Canada-Quebec Region and Environment Quebec Date: Mar 1995...cell. Exceed Set Standards? This demonstration was used to finalize operational and performance standards to be used for the audit of innovative...suspended solids measurements will be performed inside the confined area in order to audit the removal technology. All provisions should be taken to

  14. Setting Standards for Reporting and Quantification in Fluorescence-Guided Surgery.

    PubMed

    Hoogstins, Charlotte; Burggraaf, Jan Jaap; Koller, Marjory; Handgraaf, Henricus; Boogerd, Leonora; van Dam, Gooitzen; Vahrmeijer, Alexander; Burggraaf, Jacobus

    2018-05-29

    Intraoperative fluorescence imaging (FI) is a promising technique that could potentially guide oncologic surgeons toward more radical resections and thus improve clinical outcome. Despite the increase in the number of clinical trials, fluorescent agents and imaging systems for intraoperative FI, a standardized approach for imaging system performance assessment and post-acquisition image analysis is currently unavailable. We conducted a systematic, controlled comparison between two commercially available imaging systems using a novel calibration device for FI systems and various fluorescent agents. In addition, we analyzed fluorescence images from previous studies to evaluate signal-to-background ratio (SBR) and determinants of SBR. Using the calibration device, imaging system performance could be quantified and compared, exposing relevant differences in sensitivity. Image analysis demonstrated a profound influence of background noise and the selection of the background on SBR. In this article, we suggest clear approaches for the quantification of imaging system performance assessment and post-acquisition image analysis, attempting to set new standards in the field of FI.

  15. Rocky River Watershed Based Curriculum Guide Project

    NASA Astrophysics Data System (ADS)

    Cox, Phillip Howard

    Environmental education has the ability to increase cognitive ability, have a positive impact on group work skills, attitudes and self-efficacy, and increase student performance. Due to Federal "No Child Left Behind Act" legislation, increased standardized testing has resulted in the disenfranchisement of students from formal learning. The purpose of this project was to develop a curriculum guide based on the Rocky River watershed so teachers could use the Rocky River watershed as a means to satisfy the objectives of the NC Standard Course of Study and at the same time increase student environmental awareness, classroom engagement, sense of place and scores on the NC Earth/Environmental Final Exams. The project was developed to correlate with the newly revised North Carolina Standard Course of Study for Earth/Environmental Science. The curriculum guide was developed by utilizing the best practices suggested by scientific literature, the NC Standard Course of Study for Earth/Environmental Science, the North American Association for Environmental Education and the National Education Association.

  16. Cost-effectiveness of culture-guided antimicrobial prophylaxis for the prevention of infections after prostate biopsy.

    PubMed

    Li, Chi-Kong; Tong, Brian C Y; You, Joyce H S

    2016-02-01

    Clinical findings suggest that the use of rectal culture-guided antibiotic prophylaxis reduces the infection rate following transrectal ultrasound-guided prostate biopsy (TRUSBx). A decision-analytic model was designed to compare the outcomes of TRUSBx performed with (rectal culture-guided group) and without (standard ciprofloxacin prophylaxis) rectal swab culture-guided antimicrobial prophylaxis in Hong Kong. The post-biopsy infection rate, infection-related costs, quality-adjusted life years (QALYs) lost for infection, and incremental cost per QALY saved (ICER) were assessed. Model inputs were retrieved from local epidemiology data and the medical literature. A sensitivity analysis was performed to test the robustness of the model results. Base-case analysis showed that the infection rate in the culture-guided group was reduced from 2.42% to 0.23% and saved 0.0002 QALYs, with a lower cost (USD 31.4 versus USD 55.6) (USD 1=HKD 7.8). The number needed to screen to prevent an infection episode was 45.7. The hospital days avoided per 100 patients using culture-guided prophylaxis was 7.08 days. The relative effectiveness of culture-guided antimicrobial prophylaxis versus standard prophylaxis in carriers and non-carriers of FQ-resistant rectal flora were identified as potential influencing factors. In 10000 Monte Carlo simulations, ICERs of the culture-guided group were below the willingness-to-pay threshold 99.12% of the time. Using rectal culture-guided antimicrobial prophylaxis for men undergoing TRUSBx appears to be a cost-saving strategy to avert post-biopsy infection and QALY loss in Hong Kong. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Borrowing Legitimacy as English Learner (EL) Leaders: Indiana's 14-Year History with English Language Proficiency Standards

    ERIC Educational Resources Information Center

    Morita-Mullaney, Trish

    2017-01-01

    English language proficiency or English language development (ELP/D) standards guide how content-specific instruction and assessment is practiced by teachers and how English learners (ELs) at varying levels of English proficiency can perform grade-level-specific academic standards in K-12 US schools. With the transition from the state-developed…

  18. A Proposal Comparing a Clinician-Guided Patient Information Module to Standard Patient Information Evaluating Treatment Expectations of Dermal Fillers

    ERIC Educational Resources Information Center

    Warren, Hermine

    2014-01-01

    In 2011, nearly 13 million nonsurgical cosmetic procedures were performed, representing a 6% increase from the previous year. Patients often present with unrealistic treatment expectations based on beauty industry standards and misinformation. In addition, due to the lack of competency standardization in this area, providers frequently deliver…

  19. Comparing self-guided learning and educator-guided learning formats for simulation-based clinical training.

    PubMed

    Brydges, Ryan; Carnahan, Heather; Rose, Don; Dubrowski, Adam

    2010-08-01

    In this paper, we tested the over-arching hypothesis that progressive self-guided learning offers equivalent learning benefit vs. proficiency-based training while limiting the need to set proficiency standards. We have shown that self-guided learning is enhanced when students learn on simulators that progressively increase in fidelity during practice. Proficiency-based training, a current gold-standard training approach, requires achievement of a criterion score before students advance to the next learning level. Baccalaureate nursing students (n = 15/group) practised intravenous catheterization using simulators that differed in fidelity (i.e. students' perceived realism). Data were collected in 2008. Proficiency-based students advanced from low- to mid- to high-fidelity after achieving a proficiency criterion at each level. Progressive students self-guided their progression from low- to mid- to high-fidelity. Yoked control students followed an experimenter-defined progressive practice schedule. Open-ended students moved freely between the simulators. One week after practice, blinded experts evaluated students' skill transfer on a standardized patient simulation. Group differences were examined using analyses of variance. Proficiency-based students scored highest on the high-fidelity post-test (effect size = 1.22). An interaction effect showed that the Progressive and Open-ended groups maintained their performance from post-test to transfer test, whereas the Proficiency-based and Yoked control groups experienced a significant decrease (P < 0.05). Surprisingly, most Open-ended students (73%) chose the progressive practice schedule. Progressive training and proficiency-based training resulted in equivalent transfer test performance, suggesting that progressive students effectively self-guided when to transition between simulators. Students' preference for the progressive practice schedule indicates that educators should consider this sequence for simulation-based training.

  20. The Effects of Guided Imagery on Heart Rate Variability in Simulated Spaceflight Emergency Tasks Performers

    PubMed Central

    Yijing, Zhang; Xiaoping, Du; Fang, Liu; Xiaolu, Jing; Bin, Wu

    2015-01-01

    Objectives. The present study aimed to investigate the effects of guided imagery training on heart rate variability in individuals while performing spaceflight emergency tasks. Materials and Methods. Twenty-one student subjects were recruited for the experiment and randomly divided into two groups: imagery group (n = 11) and control group (n = 10). The imagery group received instructor-guided imagery (session 1) and self-guided imagery training (session 2) consecutively, while the control group only received conventional training. Electrocardiograms of the subjects were recorded during their performance of nine spaceflight emergency tasks after imagery training. Results. In both of the sessions, the root mean square of successive differences (RMSSD), the standard deviation of all normal NN (SDNN), the proportion of NN50 divided by the total number of NNs (PNN50), the very low frequency (VLF), the low frequency (LF), the high frequency (HF), and the total power (TP) in the imagery group were significantly higher than those in the control group. Moreover, LF/HF of the subjects after instructor-guided imagery training was lower than that after self-guided imagery training. Conclusions. Guided imagery was an effective regulator for HRV indices and could be a potential stress countermeasure in performing spaceflight tasks. PMID:26137491

  1. Ultrasound-guided peripheral nerve blockade.

    PubMed

    Chin, Ki Jinn; Chan, Vincent

    2008-10-01

    The use of ultrasound for peripheral nerve blockade is becoming popular. Although the feasibility of ultrasound-guided nerve blockade is now clear, it is uncertain at this time whether it represents the new standard for regional anesthesia in terms of efficacy and safety. The ability to visualize nerve location, needle advancement, needle-nerve interaction, and local anesthetic spread makes ultrasound-guided nerve block an attractive option. Study results indicate that these advantages can improve the ease of block performance, block success rates, and complications. At the same time there is evidence that ultrasound-guided regional anesthesia is a unique skill in its own right, and that proficiency in it requires training and experience. Ultrasound is a valuable tool that is now available to the regional anesthesiologist, and it is fast becoming a standard part of practice. It promises to be of especial value to the less experienced practitioner. Ultrasound does not in itself, however, guarantee the efficacy and safety of peripheral nerve blockade. Proper training in its use is required and we can expect to see the development of formal standards and guidelines in this regard.

  2. 78 FR 46796 - Federal Acquisition Regulation; Federal Acquisition Circular 2005-69; Small Entity Compliance Guide

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-01

    ... National Defense Authorization Act for Fiscal Year 2012 (Pub. L. 112-81). Expanding the definition to... Performance (FAR Case 2012-009) This rule amends FAR part 42 to provide Governmentwide standardized past performance evaluation factors and performance ratings, and to require all past performance information be...

  3. User's guide for LTGSTD24 program, Version 2. 4

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hanlon, R.L.; Connell, L.M.

    1993-05-01

    On January 30, 1989, the US Department of Energy (DOE) promulgated an interim rule entitled [open quotes]Energy Conservation Voluntary Performance Standards for New Commercial and Multi-Family High Rise Residential Buildings; Mandatory for New Federal Buildings[close quotes] (10 CFR Part 435, Subpart A). These standards require federal agencies to design all future federal commercial and multifamily high-rise residential buildings in accordance with the standards, or demonstrate that their current requirements already meet or exceed the energy-efficiency requirements of the standards. Although these newly enacted standards do not regulate the design of non-federal buildings, the DOE recommends that all design professionals usemore » the standards as guidelines for designing energy-conserving buildings. To encourage private sector use, the DOE published the standards in the January 30, 1989, Federal Register in the format typical of commercial standards. The Pacific Northwest Laboratory developed several computer programs for the DOE to make it easier for designers to comply with the standards. One of the programs, LTGSTD24 (Version 2.4), is detailed in this user's guide and is provided on the accompanying diskettes. The program will facilitate the designer's use of the standards dealing specifically with building lighting design. Using this program will greatly simplify the designer's task of performing the calculations needed to determine if a design complies with the standards.« less

  4. Every School Day Counts: The Forum Guide to Collecting and Using Attendance Data. NFES 2009-804

    ERIC Educational Resources Information Center

    National Forum on Education Statistics, 2009

    2009-01-01

    This Forum guide offers best practice suggestions on collecting and using student attendance data to improve performance. It includes a standard set of codes to make attendance data comparable across districts and states. There are real-life examples of how attendance information has been used by school districts. Chapter 1 discusses the…

  5. Laparoscopic-guided abdominal wall nerve blocks in the pediatric population: a novel technique with comparison to ultrasound-guided blocks and local wound infiltration alone.

    PubMed

    Landmann, Alessandra; Visoiu, Mihaela; Malek, Marcus M

    2018-03-01

    Abdominal wall nerve blocks have been gaining popularity for the treatment of perioperative pain in children. Our aim was to compare a technique of surgeon-performed, laparoscopic abdominal wall nerve blocks to anesthesia-placed, ultrasound-guided abdominal wall nerve blocks and the current standard of local wound infiltration. After institutional review board approval was obtained, a retrospective chart review was performed of pediatric patients treated at a single institution during a 2-year period. Statistics were calculated using analysis of variance with post-hoc Bonferonni t tests for pair-wise comparisons. Included in this study were 380 patients who received ultrasound-guided abdominal wall nerve blocks (n = 125), laparoscopic-guided abdominal wall nerve blocks (n = 88), and local wound infiltration (n = 117). Groups were well matched for age, sex, and weight. There was no significant difference in pain scores within the first 8 hours or narcotic usage between groups. Local wound infiltration demonstrated the shortest overall time required to perform (P < .0001). Patients who received a surgeon-performed abdominal wall nerve block demonstrated a shorter duration of hospital stay when compared to the other groups (P = .02). Our study has demonstrated that laparoscopic-guided abdominal wall nerve blocks show similar efficacy to ultrasound-guided nerve blocks performed by pain management physicians without increasing time in the operating room. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Preoperative computed tomography-guided percutaneous hookwire localization of metallic marker clips in the breast with a radial approach: initial experience.

    PubMed

    Uematsu, T; Kasami, M; Uchida, Y; Sanuki, J; Kimura, K; Tanaka, K; Takahashi, K

    2007-06-01

    Hookwire localization is the current standard technique for radiological marking of nonpalpable breast lesions. Stereotactic directional vacuum-assisted breast biopsy (SVAB) is of sufficient sensitivity and specificity to replace surgical biopsy. Wire localization for metallic marker clips placed after SVAB is needed. To describe a method for performing computed tomography (CT)-guided hookwire localization using a radial approach for metallic marker clips placed percutaneously after SVAB. Nineteen women scheduled for SVAB with marker-clip placement, CT-guided wire localization of marker clips, and, eventually, surgical excision were prospectively entered into the study. CT-guided wire localization was performed with a radial approach, followed by placement of a localizing marker-clip surgical excision. Feasibility and reliability of the procedure and the incidence of complications were examined. CT-guided wire localization surgical excision was successfully performed in all 19 women without any complications. The mean total procedure time was 15 min. The median distance on CT image from marker clip to hookwire was 2 mm (range 0-3 mm). CT-guided preoperative hookwire localization with a radial approach for marker clips after SVAB is technically feasible.

  7. Self-Study and Evaluation Guide; Section C-2; Financial Accounting and Service Reporting.

    ERIC Educational Resources Information Center

    National Accreditation Council for Agencies Serving the Blind and Visually Handicapped, New York, NY.

    In determining standards to judge an agency's performance in meeting its responsibilities to the public, two fundamental factors must be taken into consideration: (1) standards for financial accounting and service reporting must be formulated in the knowledge that variations among agencies will necessarily give rise to variations in applicability…

  8. The Standard of Care: Legal History and Definitions: the Bad and Good News

    PubMed Central

    Moffett, Peter; Moore, Gregory

    2011-01-01

    The true meaning of the term “the standard of care” is a frequent topic of discussion among emergency physicians as they evaluate and perform care on patients. This article, using legal cases and dictums, reviews the legal history and definitions of the standard of care. The goal is to provide the working physician with a practical and useful model of the standard of care to help guide daily practice. PMID:21691483

  9. Solar Access to Public Capital (SAPC) Working Group: Best Practices in Commercial and Industrial (C&I) Solar Photovoltaic System Installation; Period of Performance: November 28, 2014-September 1, 2015

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doyle, Chris; Loomans, Len; Truitt, Andrew

    2015-12-29

    This Best Practices in Commercial and Industrial Solar Photovoltaic System Installation Guide is the second of a series of guides designed to standardize and improve solar asset transparency for investors and rating agencies, provide an industry framework for quality management, and reduce transaction costs in the solar asset securitization process. The Best Practices in C&I PV System Installation Guide is intended to outline the minimum requirements for commercial and industrial solar project developments. Adherence to the guide is voluntary. Providers that adhere to the guide are responsible for self-certifying that they have fulfilled the guide requirements. Investors and rating agenciesmore » should verify compliance.« less

  10. ASTM Committee C28: International Standards for Properties and Performance of Advanced Ceramics, Three Decades of High-quality, Technically-rigorous Normalization

    NASA Technical Reports Server (NTRS)

    Jenkins, Michael G.; Salem, Jonathan A.

    2016-01-01

    Physical and mechanical properties and performance of advanced ceramics and glasses are difficult to measure correctly without the proper techniques. For over three decades, ASTM Committee C28 on Advanced Ceramics, has developed high quality, rigorous, full-consensus standards (e.g., test methods, practices, guides, terminology) to measure properties and performance of monolithic and composite ceramics that may be applied to glasses in some cases. These standards testing particulars for many mechanical, physical, thermal, properties and performance of these materials. As a result these standards provide accurate, reliable, repeatable and complete data. Within Committee C28 users, producers, researchers, designers, academicians, etc. have written, continually updated, and validated through round-robin test programs, nearly 50 standards since the Committees founding in 1986. This paper provides a retrospective review of the 30 years of ASTM Committee C28 including a graphical pictogram listing of C28 standards along with examples of the tangible benefits of advanced ceramics standards to demonstrate their practical applications.

  11. Users guide for ENVSTD program Version 2. 0 and LTGSTD program Version 2. 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crawley, D.B.; Riesen, P.K.; Briggs, R.S.

    1989-02-01

    On January 30, 1989, the US Department of Energy (DOE) promulgated 10 CFR Part 435, Subpart A, an Interim Rule entitled ''Energy Conservation Voluntary Performance Standards for New Commercial and Multi-Family High Rise Residential Buildings; Mandatory for New Federal Buildings.'' As a consequence, federal agencies must design all future federal commercial and multifamily high rise residential buildings in accordance with the Standards, or show that their current standards already meet or exceed the energy-efficiency requirements of the Standards. Although these newly enacted Standards do not regulate the design of nonfederal buildings, DOE recommends that all design professionals use the Standardsmore » as guidelines for designing energy-conserving buildings. To encourage private sector use, the Standards were presented in the January 30, 1989, Federal Register in the format typical of commercial standards rather than a federal regulation. As a further help, DOE supported the development of various microcomputer programs to ease the use of the Standards. Two of these programs/emdash/ENVSTD (Version 2.0) and LTGSTD (Version 2.0)/emdash/are detailed in this users guide and provided on the accompanying diskette. This package, developed by Pacific Northwest Laboratory (PNL), is intended to facilitate the designer's use of the Standards dealing specifically with a building's envelope and lighting system designs. Using these programs will greatly simplify the designer's task of performing the sometimes complex calculations needed to determine a design's compliance with the Standards. 3 refs., 6 figs.« less

  12. Prospective evaluation of magnetic resonance imaging guided in-bore prostate biopsy versus systematic transrectal ultrasound guided prostate biopsy in biopsy naïve men with elevated prostate specific antigen.

    PubMed

    Quentin, Michael; Blondin, Dirk; Arsov, Christian; Schimmöller, Lars; Hiester, Andreas; Godehardt, Erhard; Albers, Peter; Antoch, Gerald; Rabenalt, Robert

    2014-11-01

    Magnetic resonance imaging guided biopsy is increasingly performed to diagnose prostate cancer. However, there is a lack of well controlled, prospective trials to support this treatment method. We prospectively compared magnetic resonance imaging guided in-bore biopsy with standard systematic transrectal ultrasound guided biopsy in biopsy naïve men with increased prostate specific antigen. We performed a prospective study in 132 biopsy naïve men with increased prostate specific antigen (greater than 4 ng/ml). After 3 Tesla functional multiparametric magnetic resonance imaging patients were referred for magnetic resonance imaging guided in-bore biopsy of prostate lesions (maximum 3) followed by standard systematic transrectal ultrasound guided biopsy (12 cores). We analyzed the detection rates of prostate cancer and significant prostate cancer (greater than 5 mm total cancer length or any Gleason pattern greater than 3). A total of 128 patients with a mean ± SD age of 66.1 ± 8.1 years met all study requirements. Median prostate specific antigen was 6.7 ng/ml (IQR 5.1-9.0). Transrectal ultrasound and magnetic resonance imaging guided biopsies provided the same 53.1% detection rate, including 79.4% and 85.3%, respectively, for significant prostate cancer. Magnetic resonance imaging and transrectal ultrasound guided biopsies missed 7.8% and 9.4% of clinically significant prostate cancers, respectively. Magnetic resonance imaging biopsy required significantly fewer cores and revealed a higher percent of cancer involvement per biopsy core (each p <0.01). Combining the 2 methods provided a 60.9% detection rate with an 82.1% rate for significant prostate cancer. Magnetic resonance imaging guided in-bore and systematic transrectal ultrasound guided biopsies achieved equally high detection rates in biopsy naïve patients with increased prostate specific antigen. Magnetic resonance imaging guided in-bore biopsies required significantly fewer cores and revealed a significantly higher percent of cancer involvement per biopsy core. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  13. 42 CFR 423.160 - Standards for electronic prescribing.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Prescriber/Pharmacist Interface SCRIPT Standard, Implementation Guide, Version 8, Release 1, (Version 8.1... Prescriber/Pharmacist Interface SCRIPT Standard, Implementation Guide, Version 8, Release 1 (Version 8.1... Programs Prescriber/Pharmacist Interface SCRIPT Standard, Implementation Guide Version 8, Release 1...

  14. Enhancing compliance at Department of Defense facilities: comparison of three environmental audit tools.

    PubMed

    Hepler, Jeff A; Neumann, Cathy

    2003-04-01

    To enhance environmental compliance, the U.S. Department of Defense (DOD) recently developed and implemented a standardized environmental audit tool called The Environmental Assessment and Management (TEAM) Guide. Utilization of a common audit tool (TEAM Guide) throughout DOD agencies could be an effective agent of positive change. If, however, the audit tool is inappropriate, environmental compliance at DOD facilities could worsen. Furthermore, existing audit systems such as the U.S. Environmental Protection Agency's (U.S. EPA's) Generic Protocol for Conducting Environmental Audits of Federal Facilities and the International Organization for Standardization's (ISO's) Standard 14001, "Environmental Management System Audits," may be abandoned even if they offer significant advantages over TEAM Guide audit tool. Widespread use of TEAM Guide should not take place until thorough and independent evaluation has been performed. The purpose of this paper is to compare DOD's TEAM Guide audit tool with U.S. EPA's Generic Protocol for Conducting Environmental Audits of Federal Facilities and ISO 14001, in order to assess which is most appropriate and effective for DOD facilities, and in particular those operated by the U.S. Army Corps of Engineers (USACE). USACE was selected as a result of one author's recent experience as a district environmental compliance coordinator responsible for the audit mission at this agency. Specific recommendations for enhancing the quality of environmental audits at all DOD facilities also are given.

  15. Mobile Robot and Mobile Manipulator Research Towards ASTM Standards Development.

    PubMed

    Bostelman, Roger; Hong, Tsai; Legowik, Steven

    2016-01-01

    Performance standards for industrial mobile robots and mobile manipulators (robot arms onboard mobile robots) have only recently begun development. Low cost and standardized measurement techniques are needed to characterize system performance, compare different systems, and to determine if recalibration is required. This paper discusses work at the National Institute of Standards and Technology (NIST) and within the ASTM Committee F45 on Driverless Automatic Guided Industrial Vehicles. This includes standards for both terminology, F45.91, and for navigation performance test methods, F45.02. The paper defines terms that are being considered. Additionally, the paper describes navigation test methods that are near ballot and docking test methods being designed for consideration within F45.02. This includes the use of low cost artifacts that can provide alternatives to using relatively expensive measurement systems.

  16. Mobile Robot and Mobile Manipulator Research Towards ASTM Standards Development

    PubMed Central

    Bostelman, Roger; Hong, Tsai; Legowik, Steven

    2017-01-01

    Performance standards for industrial mobile robots and mobile manipulators (robot arms onboard mobile robots) have only recently begun development. Low cost and standardized measurement techniques are needed to characterize system performance, compare different systems, and to determine if recalibration is required. This paper discusses work at the National Institute of Standards and Technology (NIST) and within the ASTM Committee F45 on Driverless Automatic Guided Industrial Vehicles. This includes standards for both terminology, F45.91, and for navigation performance test methods, F45.02. The paper defines terms that are being considered. Additionally, the paper describes navigation test methods that are near ballot and docking test methods being designed for consideration within F45.02. This includes the use of low cost artifacts that can provide alternatives to using relatively expensive measurement systems. PMID:28690359

  17. Feasibility of virtual 3-Fr percutaneous coronary intervention using standard guiding catheters

    PubMed Central

    Fujimoto, Kazuteru; Miyao, Yuji

    2014-01-01

    Introduction Recent studies have reported the efficacy of sheathless percutaneous coronary intervention (PCI) using hydrophilic-coated 5-Fr guiding catheters that are one to two Fr sizes smaller in diameter than the corresponding introducer sheath (virtual 3-Fr PCI). However, the limited number of shapes of hydrophilic-coated guiding catheters occasionally makes them difficult to engage and control. Aim To evaluate the efficacy and feasibility of virtual 3-Fr PCI using standard guiding catheters of various shapes. Material and methods We identified 35 consecutive patients with stable angina, who underwent virtual 3-Fr PCI using either hydrophilic-coated guiding catheters (Works™, Medikit, Japan) or standard guiding catheters (Heartrail™, Terumo, Japan). Results Thirty-five patients were identified (63% men; mean age 70 ±13 years). In 2 cases, hydrophilic-coated guiding catheters were exchanged to standard guiding catheters because of difficulty in engaging the target coronary arteries. Ultimately, standard guiding catheters were used in 20 patients (57%) and hydrophilic-coated catheters were used in 15 (43%). One of 20 patients treated with standard guiding catheters and 1 of 15 treated with hydrophilic-coated guiding catheters underwent the 4-in-3 “slender mother and child” PCI technique due to difficulty of stent deployment. There were no differences between the two groups in PCI procedural variables such as procedural time, fluoroscopy time, radiation dose, or contrast dye volume. There were no access site-related complications in this study. Conclusions These findings indicate that virtual 3-Fr PCI using standard guiding catheters is as efficient and safe as virtual 3-Fr PCI using hydrophilic-coated guiding catheters. PMID:25489315

  18. Guide Specification For Devices Used To Board Airline Passengers with Mobility Impairments

    DOT National Transportation Integrated Search

    2000-03-17

    This advisory circular (AC) contains performance standards, specifications, and : recommendations for the design, construction, and testing of portable devices : used in the boarding of airline passengers with mobility impairments. Larger : aircraft ...

  19. V-TECS Guide for Auto Mechanics: Suspension Systems, Brakes and Steering.

    ERIC Educational Resources Information Center

    Moore, Charles G.; And Others

    The materials in this document are an extension of a catalog of occupational duties, tasks, and performance objectives relevant to maintaining automotive suspension systems, brakes, and steering mechanisms. This document provides the following for each occupational task within each duty: (1) a standard of performance; (2) the conditions under…

  20. Guide Specification For Small, Dual Agent Aircraft Rescue and Firefighting Vehicles

    DOT National Transportation Integrated Search

    1993-12-07

    This advisory circular (AC) contains performance standards, specifications, and : recommendations for the design, construction, and testing of a family of small, : dual agent aircraft rescue and fire fighting (ARFF) vehicles. The National : Fire Prot...

  1. Spine epidural and sacroiliac joints injections--when and how to perform.

    PubMed

    D'Orazio, Federico; Gregori, Lorenzo Maria; Gallucci, Massimo

    2015-05-01

    To review the state-of-the-art of image-guided techniques used to treat painful syndromes of the lower back, their indications, how they should be performed, their related risks and the expected results. We describe the actual standards about image-guided infiltrative therapies both on spine and on sacroiliac joints. Both spinal epidural and sacroiliac injections appear useful in a large percentage of treated patients to get control of the perceived pain. Performing these therapies under CT or fluoroscopic guidance is the best and safest way to obtain satisfactory results because it is possible to target the use of drugs directly to the involved painful structures. Image-guided injections of the epidural space and of the sacroiliac joints are effective techniques for the treatment of pain; their effectiveness is sometimes not lasting for long periods of time but considering the low associated risk when performed by trained personnel, they can be easily repeated. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  2. Robotic Needle Guide for Prostate Brachytherapy: Clinical Testing of Feasibility and Performance

    PubMed Central

    Song, Danny Y; Burdette, Everette C; Fiene, Jonathan; Armour, Elwood; Kronreif, Gernot; Deguet, Anton; Zhang, Zhe; Iordachita, Iulian; Fichtinger, Gabor; Kazanzides, Peter

    2010-01-01

    Purpose Optimization of prostate brachytherapy is constrained by tissue deflection of needles and fixed spacing of template holes. We developed and clinically tested a robotic guide towards the goal of allowing greater freedom of needle placement. Methods and Materials The robot consists of a small tubular needle guide attached to a robotically controlled arm. The apparatus is mounted and calibrated to operate in the same coordinate frame as a standard template. Translation in x and y directions over the perineum ±40mm are possible. Needle insertion is performed manually. Results Five patients were treated in an IRB-approved study. Confirmatory measurements of robotic movements for initial 3 patients using infrared tracking showed mean error of 0.489 mm (SD 0.328 mm). Fine adjustments in needle positioning were possible when tissue deflection was encountered; adjustments were performed in 54/179 (30.2%) needles placed, with 36/179 (20.1%) adjustments of > 2mm. Twenty-seven insertions were intentionally altered to positions between the standard template grid to improve the dosimetric plan or avoid structures such as pubic bone and blood vessels. Conclusions Robotic needle positioning provided a means of compensating for needle deflections as well as the ability to intentionally place needles into areas between the standard template holes. To our knowledge, these results represent the first clinical testing of such a system. Future work will be incorporation of direct control of the robot by the physician, adding software algorithms to help avoid robot collisions with the ultrasound, and testing the angulation capability in the clinical setting. PMID:20729152

  3. Single-operator real-time ultrasound-guided spinal injection using SonixGPS™: a case series.

    PubMed

    Brinkmann, Silke; Tang, Raymond; Sawka, Andrew; Vaghadia, Himat

    2013-09-01

    The SonixGPS™ is a novel needle tracking system that has recently been approved in Canada for ultrasound-guided needle interventions. It allows optimization of needle-beam alignment by providing a real-time display of current and predicted needle tip position. Currently, there is limited evidence on the effectiveness of this technique for performance of real-time spinal anesthesia. This case series reports performance of the SonixGPS system for real-time ultrasound-guided spinal anesthesia in elective patients scheduled for joint arthroplasty. In this single-centre case series, 20 American Society of Anesthesiologists' class I-II patients scheduled for lower limb joint arthroplasty were recruited to undergo real-time ultrasound-guided spinal anesthesia with the SonixGPS after written informed consent. The primary outcome for this clinical cases series was the success rate of spinal anesthesia, and the main secondary outcome was time required to perform spinal anesthesia. Successful spinal anesthesia for joint arthroplasty was achieved in 18/20 patients, and 17 of these required only a single skin puncture. In 7/20 (35%) patients, dural puncture was achieved on the first needle pass, and in 11/20 (55%) patients, dural puncture was achieved with two or three needle redirections. Median (range) time taken to perform the block was 8 (5-14) min. The study procedure was aborted in two cases because our clinical protocol dictated using a standard approach if spinal anesthesia was unsuccessful after three ultrasound-guided insertion attempts. These two cases were classified as failures. No complications, including paresthesia, were observed during the procedure. All patients with successful spinal anesthesia found the technique acceptable and were willing to undergo a repeat procedure if deemed necessary. This case series shows that real-time ultrasound-guided spinal anesthesia with the SonixGPS system is possible within an acceptable time frame. It proved effective with a low rate of failure and a low rate of complications. Our clinical experience suggests that a randomized trial is warranted to compare the SonixGPS with a standard block technique.

  4. Clinical Assessment of Risk Management: an INtegrated Approach (CARMINA).

    PubMed

    Tricarico, Pierfrancesco; Tardivo, Stefano; Sotgiu, Giovanni; Moretti, Francesca; Poletti, Piera; Fiore, Alberto; Monturano, Massimo; Mura, Ida; Privitera, Gaetano; Brusaferro, Silvio

    2016-08-08

    Purpose - The European Union recommendations for patient safety calls for shared clinical risk management (CRM) safety standards able to guide organizations in CRM implementation. The purpose of this paper is to develop a self-evaluation tool to measure healthcare organization performance on CRM and guide improvements over time. Design/methodology/approach - A multi-step approach was implemented including: a systematic literature review; consensus meetings with an expert panel from eight Italian leader organizations to get to an agreement on the first version; field testing to test instrument feasibility and flexibility; Delphi strategy with a second expert panel for content validation and balanced scoring system development. Findings - The self-assessment tool - Clinical Assessment of Risk Management: an INtegrated Approach includes seven areas (governance, communication, knowledge and skills, safe environment, care processes, adverse event management, learning from experience) and 52 standards. Each standard is evaluated according to four performance levels: minimum; monitoring; outcomes; and improvement actions, which resulted in a feasible, flexible and valid instrument to be used throughout different organizations. Practical implications - This tool allows practitioners to assess their CRM activities compared to minimum levels, monitor performance, benchmarking with other institutions and spreading results to different stakeholders. Originality/value - The multi-step approach allowed us to identify core minimum CRM levels in a field where no consensus has been reached. Most standards may be easily adopted in other countries.

  5. ASTM Committee C28: International Standards for Properties and Performance of Advanced Ceramics-Three Decades of High-Quality, Technically-Rigorous Normalization

    NASA Technical Reports Server (NTRS)

    Jenkins, Michael G.; Salem, Jonathan A.

    2016-01-01

    Physical and mechanical properties and performance of advanced ceramics and glasses are difficult to measure correctly without the proper techniques. For over three decades, ASTM Committee C28 on Advanced Ceramics, has developed high-quality, technically-rigorous, full-consensus standards (e.g., test methods, practices, guides, terminology) to measure properties and performance of monolithic and composite ceramics that may be applied to glasses in some cases. These standards contain testing particulars for many mechanical, physical, thermal, properties and performance of these materials. As a result these standards are used to generate accurate, reliable, repeatable and complete data. Within Committee C28, users, producers, researchers, designers, academicians, etc. have written, continually updated, and validated through round-robin test programs, 50 standards since the Committee's founding in 1986. This paper provides a detailed retrospective of the 30 years of ASTM Committee C28 including a graphical pictogram listing of C28 standards along with examples of the tangible benefits of standards for advanced ceramics to demonstrate their practical applications.

  6. A Program Manager’s Guide for Program Improvement in Ongoing Psychological Health and Traumatic Brain Injury Programs. The RAND Toolkit, Volume 4

    DTIC Science & Technology

    2014-01-01

    Hughes EFX, Boerstler H, O’Connor EJ. “Assessing the Impact of Continuous Quality Improvement/ Total Quality Management : Concept versus...facing the public and private sectors. All RAND reports undergo rigorous peer review to ensure high standards for research quality and objectivity. Gery...RAND Program Manager’s Guide helps managers assess program performance, consider options for improvement, implement solutions, then assess whether the

  7. A Randomized Double-Blinded Trial on the Effects of Ultrasound Transducer Orientation on Teaching and Learning Ultrasound-Guided Regional Anesthesia.

    PubMed

    Lam, Nicholas C K; Baker, Elizabeth B; Fishburn, Steven J; Hammer, Angie R; Petersen, Timothy R; Mariano, Edward R

    2016-07-01

    Learning ultrasound-guided regional anesthesia skills, especially needle/ beam alignment, can be especially difficulty for trainees, who can often become frustrated. We hypothesized that teaching novices to orient the transducer and needle perpendicular to their shoulders will improve performance on a standardized task, compared to holding the transducer and needle parallel to the shoulders. This study compared the effects of transducer orientation on trainees' ability to complete a standardized ultrasound-guided nerve block simulation. The time to task completion and percentage of the attempt time without adequate needle visualization were measured. Participants were right-handed healthy adults with no previous ultrasound experience and were randomly assigned to training in either transducer and needle alignment in a coronal plane, parallel to the shoulders (parallel group) or transducer and needle alignment in a sagittal plane, perpendicular to the shoulders (perpendicular group). Participants used ultrasound to direct a needle to 3 targets in a standardized gelatin phantom and repeated this task 3 times. Their efforts were timed and evaluated by an assessor, who was blinded to group assignment. Data were analyzed on 28 participants. The perpendicular group was able to complete the task more quickly (P < .001) and with a smaller proportion of time lost to inadequate needle visualization (P < .001). Ultrasound-guided regional anesthesia trainees complete a standardized task more quickly and efficiently when instructed to hold the transducer and needle in an orientation perpendicular to their shoulders.

  8. Wire-guided sphincterotomy.

    PubMed

    Sherman, S; Uzer, M F; Lehman, G A

    1994-12-01

    Guidewire-assisted techniques have acquired an important role in endoscopic interventions in the pancreaticobiliary tree. The wire-guided sphincterotome allows the endoscopist to maintain direct access to the biliary tree before or after the sphincterotomy. It has the additional advantages of allowing for more expeditious placement of accessories and being useful in combined percutaneous-endoscopic procedures. There are two basic designs of wire-guided sphincterotomes. The single-channel model has a single lumen for both the cutting wire and guidewire and requires guidewire removal before the application of power. The double-channel model has two separate lumens for the guidewire and stainless steel cutting wire. In vitro data suggest that significant capacitive coupling currents (or short circuits) may occur on the standard Teflon-coated guidewire when used with a double lumen sphincterotome, resulting in electrosurgical burns. Thus, the manufacturers of the double-lumen models recommend removing the Teflon-coated wire before performing sphincterotomy. Although limited data in humans have been published, it appears that wire-guided sphincterotomy and standard sphincterotomy have similar complication rates. More safety information in humans is awaited.

  9. Performance-Based Curriculum for Language Arts: From Knowing to Showing.

    ERIC Educational Resources Information Center

    Burz, Helen L.; Marshall, Kit

    This book is intended to be used as a guide to develop a performance-based curriculum based on language arts standards recommended by the National Council of Teachers of English and the International Reading Association. The book helps teachers take their students beyond knowledge and basic skills by teaching them to be accountable for showing…

  10. Georgia Long-Term Pavement Performance (GALTPP) Program – Maintaining Georgia’s Calibration Sites and Identifying the Potential for Using MEPDG for Characterization of Non-Standard Materials and Methods (Phase 1)

    DOT National Transportation Integrated Search

    2016-10-01

    The Georgia Department of Transportation (GDOT) has initiated a Georgia Long-Term Pavement Performance (GALTPP) monitoring program 1) to provide data for calibrating the prediction models in the AASHTO Mechanistic-Empirical Pavement Design Guide (MEP...

  11. Evaluation of a Standardized Program for Training Practicing Anesthesiologists in Ultrasound-Guided Regional Anesthesia Skills.

    PubMed

    Mariano, Edward R; Harrison, T Kyle; Kim, T Edward; Kan, Jack; Shum, Cynthia; Gaba, David M; Ganaway, Toni; Kou, Alex; Udani, Ankeet D; Howard, Steven K

    2015-10-01

    Practicing anesthesiologists have generally not received formal training in ultrasound-guided perineural catheter insertion. We designed this study to determine the efficacy of a standardized teaching program in this population. Anesthesiologists in practice for 10 years or more were recruited and enrolled to participate in a 1-day program: lectures and live-model ultrasound scanning (morning) and faculty-led iterative practice and mannequin-based simulation (afternoon). Participants were assessed and recorded while performing ultrasound-guided perineural catheter insertion at baseline, at midday (interval), and after the program (final). Videos were scored by 2 blinded reviewers using a composite tool and global rating scale. Participants were surveyed every 3 months for 1 year to report the number of procedures, efficacy of teaching methods, and implementation obstacles. Thirty-two participants were enrolled and completed the program; 31 of 32 (97%) completed the 1-year follow-up. Final scores [median (10th-90th percentiles)] were 21.5 (14.5-28.0) of 30 points compared to 14.0 (9.0-20.0) at interval (P < .001 versus final) and 12.0 (8.5-17.5) at baseline (P < .001 versus final), with no difference between interval and baseline. The global rating scale showed an identical pattern. Twelve of 26 participants without previous experience performed at least 1 perineural catheter insertion after training (P < .001). However, there were no differences in the monthly average number of procedures or complications after the course when compared to baseline. Practicing anesthesiologists without previous training in ultrasound-guided regional anesthesia can acquire perineural catheter insertion skills after a 1-day standardized course, but changing clinical practice remains a challenge. © 2015 by the American Institute of Ultrasound in Medicine.

  12. Spread Spectrum Receiver Electromagnetic Interference (EMI) Test Guide

    NASA Technical Reports Server (NTRS)

    Wheeler, Mark L.

    1998-01-01

    This program consisted of: (1) a study to define appropriate EMI test guidelines and test methods for direct sequence (DS) spread spectrum receivers; and (2) preparation of a written test guide to document the recommended test methods. The scope of this test guide includes: (1) a discussion of generic DS receiver performance characteristics; (2) a summary of S-band TDRSS receiver operation; (3) a discussion of DS receiver EMI susceptibility mechanisms and characteristics; (4) a summary of military standard test guidelines; (5) recommended test approach and methods; and (6) general conclusions and recommendations for future studies in the area of spread spectrum receiver testing.

  13. Differences in Weight Loss Between Persons on Standard Balanced vs Nutrigenetic Diets in a Randomized Controlled Trial.

    PubMed

    Frankwich, Karen A; Egnatios, Jeremy; Kenyon, Mandy L; Rutledge, Thomas R; Liao, Patricia S; Gupta, Samir; Herbst, Karen L; Zarrinpar, Amir

    2015-09-01

    Many companies provide genetic tests for obesity-related polymorphisms (nutrigenetics) and make dietary recommendations for weight loss that are based on the results. We performed a randomized controlled trial to determine whether more participants who followed a nutrigenetic-guided diet lost ≥5% of their body weight than participants on a standard balanced diet for 8 and 24 weeks. We performed a prospective study of 51 obese or overweight U.S. veterans on an established weight management program at the Veterans Administration San Diego Healthcare System (the MOVE! program). Participants were randomly assigned to groups placed on a nutrigenetic-guided diet (balanced, low-carbohydrate, low-fat, or Mediterranean; n = 30) or a standard balanced diet (n = 21). Nutrigenetic diets were selected on the basis of results from the Pathway FIT test. There was no significant difference in the percentage of participants on the balanced diet vs the nutrigenetic-guided diet who lost 5% of their body weight at 8 weeks (35.0% ± 20.9% vs 26.9% ± 17.1%, respectively; P = .28) or at 24 weeks. Both groups had difficulty adhering to the diets. However, adherence to the nutrigenetic-guided diet correlated with weight loss (r = 0.74; P = 4.0 × 10(-5)), but not adherence to standard therapy (r = 0.34; P = .23). Participants who had low-risk polymorphisms for obesity lost more weight than all other participants at 8 weeks (5.0% vs 2.9%, respectively; P = .02) and had significantly greater reductions in body mass index (6.4% vs 3.6%, respectively; P = .03) and waist circumference (6.5% vs 2.6%, respectively; P = .02) at 24 weeks. In a prospective study, a nutrigenetic-based diet did not increase weight loss compared with a standard balanced diet. However, genetic features can identify individuals most likely to benefit from a balanced diet weight loss strategy; these findings require further investigation. ClinicalTrials.gov number: NCT01859403. Copyright © 2015 AGA Institute. Published by Elsevier Inc. All rights reserved.

  14. Development and Use of Engineering Standards for Computational Fluid Dynamics for Complex Aerospace Systems

    NASA Technical Reports Server (NTRS)

    Lee, Hyung B.; Ghia, Urmila; Bayyuk, Sami; Oberkampf, William L.; Roy, Christopher J.; Benek, John A.; Rumsey, Christopher L.; Powers, Joseph M.; Bush, Robert H.; Mani, Mortaza

    2016-01-01

    Computational fluid dynamics (CFD) and other advanced modeling and simulation (M&S) methods are increasingly relied on for predictive performance, reliability and safety of engineering systems. Analysts, designers, decision makers, and project managers, who must depend on simulation, need practical techniques and methods for assessing simulation credibility. The AIAA Guide for Verification and Validation of Computational Fluid Dynamics Simulations (AIAA G-077-1998 (2002)), originally published in 1998, was the first engineering standards document available to the engineering community for verification and validation (V&V) of simulations. Much progress has been made in these areas since 1998. The AIAA Committee on Standards for CFD is currently updating this Guide to incorporate in it the important developments that have taken place in V&V concepts, methods, and practices, particularly with regard to the broader context of predictive capability and uncertainty quantification (UQ) methods and approaches. This paper will provide an overview of the changes and extensions currently underway to update the AIAA Guide. Specifically, a framework for predictive capability will be described for incorporating a wide range of error and uncertainty sources identified during the modeling, verification, and validation processes, with the goal of estimating the total prediction uncertainty of the simulation. The Guide's goal is to provide a foundation for understanding and addressing major issues and concepts in predictive CFD. However, this Guide will not recommend specific approaches in these areas as the field is rapidly evolving. It is hoped that the guidelines provided in this paper, and explained in more detail in the Guide, will aid in the research, development, and use of CFD in engineering decision-making.

  15. CONTROLLING PCDD/PCDF EMISSIONS FROM INCINERATORS BY FLUE GAS CLEANING

    EPA Science Inventory

    The paper discusses controlling polychlorinated dibenzo-p-dioxin and dibenzofuran (PCDF) emissions from incinerators by flue gas cleaning. New Source performance Standards for municipal waste combustors (MWCs) and guide-lines for existing incinerators in the U.S., proposed on Dec...

  16. Initial Burn Pan (JMTF) Testing Results

    DTIC Science & Technology

    2016-03-01

    of Testing and Materials (ASTM) standard for fire - resistant boom. It had not been used for over 15 years and was almost completely destroyed when...Environment Canada had produced operational guides, provided standards for fire - resistant booms and igniting techniques needed to perform offshore burns...are currently in the smoke zone; and the heat from the fire could be felt from that area. While no one was injured, some miscommunication at the

  17. Stepping Stones To Using "Caring for Our Children": National Health and Safety Performance Standards for Out-of-Home Child Care Programs. Protecting Children from Harm.

    ERIC Educational Resources Information Center

    Colorado Univ. Health Sciences Center, Denver.

    Developed in support of state licensing and regulatory agencies as well as state child care, health, and resource and referral agencies, and a variety of other public and private organizations, parents, and advocacy groups, this guide identifies those standards most needed for the prevention of injury, morbidity, and mortality in child care…

  18. Reformation of Regulatory Technical Standards for Nuclear Power Generation Equipments in Japan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mikio Kurihara; Masahiro Aoki; Yu Maruyama

    2006-07-01

    Comprehensive reformation of the regulatory system has been introduced in Japan in order to apply recent technical progress in a timely manner. 'The Technical Standards for Nuclear Power Generation Equipments', known as the Ordinance No.622) of the Ministry of International Trade and Industry, which is used for detailed design, construction and operating stage of Nuclear Power Plants, was being modified to performance specifications with the consensus codes and standards being used as prescriptive specifications, in order to facilitate prompt review of the Ordinance with response to technological innovation. The activities on modification were performed by the Nuclear and Industrial Safetymore » Agency (NISA), the regulatory body in Japan, with support of the Japan Nuclear Energy Safety Organization (JNES), a technical support organization. The revised Ordinance No.62 was issued on July 1, 2005 and is enforced from January 1 2006. During the period from the issuance to the enforcement, JNES carried out to prepare enforceable regulatory guide which complies with each provisions of the Ordinance No.62, and also made technical assessment to endorse the applicability of consensus codes and standards, in response to NISA's request. Some consensus codes and standards were re-assessed since they were already used in regulatory review of the construction plan submitted by licensee. Other consensus codes and standards were newly assessed for endorsement. In case that proper consensus code or standards were not prepared, details of regulatory requirements were described in the regulatory guide as immediate measures. At the same time, appropriate standards developing bodies were requested to prepare those consensus code or standards. Supplementary note which provides background information on the modification, applicable examples etc. was prepared for convenience to the users of the Ordinance No. 62. This paper shows the activities on modification and the results, following the NISA's presentation at ICONE-13 that introduced the framework of the performance specifications and the modification process of the Ordinance NO. 62. (authors)« less

  19. Study on Construction Technology Standardization of Primary Guide Rope Laying by Multi-rotor Aircraft in Stringing Construction of Transmission Line

    NASA Astrophysics Data System (ADS)

    Liu, Chen; Tang, Guang-Rui; Jiang, Ming; Dong, Yu-Ming

    2017-09-01

    According to the practical situation of stringing construction for Ultra High Voltage (UHV) overhead transmission line, construction technology standardization of primary guide rope laying by multi-rotor aircraft is studied. This paper mainly focuses on the construction preparation, test flight and technology of laying primary guide rope. The summary of the construction technology standardization of primary guide rope laying by multi-rotor aircraft in stringing construction are useful in further guiding practical construction of transmission line.

  20. Process oriented guided inquiry learning (POGIL®) marginally effects student achievement measures but substantially increases the odds of passing a course.

    PubMed

    Walker, Lindsey; Warfa, Abdi-Rizak M

    2017-01-01

    While the inquiry approach to science teaching has been widely recommended as an epistemic mechanism to promote deep content understanding, there is also increased expectation that process and other transferable skills should be integral part of science pedagogy. To test the hypothesis that coupling process skills to content teaching impacts academic success measures, we meta-analyzed twenty-one studies (n = 21) involving 7876 students that compared Process Oriented Guided Inquiry Learning (POGIL), a pedagogy that provides opportunities for improving process skills during content learning through guided-inquiry activities, to standard lecture conditions. Based on conventional measures of class performance, POGIL had a small effect on achievement outcomes (effect size = 0.29, [95% CI = 0.15-0.43]) but substantially improved the odds of passing a class (odds ratio = 2.02, [95% CI: 1.45-2.83]). That is, participants in the POGIL pedagogy had higher odds of passing a course and roughly performed 0.3 standard deviations higher on achievement measures than participants in standard lectures. In relative risk terms, POGIL reduced the risk of failing a course by 38%. These findings suggest providing opportunities to improve process skills during class instruction does not inhibit content learning but enhances conventional success measures. We compare these findings with those of recent large meta-analysis that examined the effects of global active learning methods on achievement outcomes and course failure rates in science, technology, engineering, and mathematics (STEM) fields.

  1. Process oriented guided inquiry learning (POGIL®) marginally effects student achievement measures but substantially increases the odds of passing a course

    PubMed Central

    Walker, Lindsey

    2017-01-01

    While the inquiry approach to science teaching has been widely recommended as an epistemic mechanism to promote deep content understanding, there is also increased expectation that process and other transferable skills should be integral part of science pedagogy. To test the hypothesis that coupling process skills to content teaching impacts academic success measures, we meta-analyzed twenty-one studies (n = 21) involving 7876 students that compared Process Oriented Guided Inquiry Learning (POGIL), a pedagogy that provides opportunities for improving process skills during content learning through guided-inquiry activities, to standard lecture conditions. Based on conventional measures of class performance, POGIL had a small effect on achievement outcomes (effect size = 0.29, [95% CI = 0.15–0.43]) but substantially improved the odds of passing a class (odds ratio = 2.02, [95% CI: 1.45–2.83]). That is, participants in the POGIL pedagogy had higher odds of passing a course and roughly performed 0.3 standard deviations higher on achievement measures than participants in standard lectures. In relative risk terms, POGIL reduced the risk of failing a course by 38%. These findings suggest providing opportunities to improve process skills during class instruction does not inhibit content learning but enhances conventional success measures. We compare these findings with those of recent large meta-analysis that examined the effects of global active learning methods on achievement outcomes and course failure rates in science, technology, engineering, and mathematics (STEM) fields. PMID:29023502

  2. Teachers Harness the Power of Assessment: Collaborative Use of Student Data Gauges Performance and Guides Instruction

    ERIC Educational Resources Information Center

    Herman, Phillip; Wardrip, Peter; Hall, Ashley; Chimino, Amy

    2012-01-01

    Improving systematic use of student data to inform the work of teachers, schools, and districts has become a hot topic in education reform. Learning Forward's Standards for Professional Learning stress better use of data, and particularly student performance data, within an integrated approach to improving practice. While better use of data by…

  3. Guide to Flow Measurement for Electric Propulsion Systems

    NASA Technical Reports Server (NTRS)

    Frieman, Jason D.; Walker, Mitchell L. R.; Snyder, Steve

    2013-01-01

    In electric propulsion (EP) systems, accurate measurement of the propellant mass flow rate of gas or liquid to the thruster and external cathode is a key input in the calculation of thruster efficiency and specific impulse. Although such measurements are often achieved with commercial mass flow controllers and meters integrated into propellant feed systems, the variability in potential propellant options and flow requirements amongst the spectrum of EP power regimes and devices complicates meter selection, integration, and operation. At the direction of the Committee on Standards for Electric Propulsion Testing, a guide was jointly developed by members of the electric propulsion community to establish a unified document that contains the working principles, methods of implementation and analysis, and calibration techniques and recommendations on the use of mass flow meters in laboratory and spacecraft electric propulsion systems. The guide is applicable to EP devices of all types and power levels ranging from microthrusters to high-power ion engines and Hall effect thrusters. The establishment of a community standard on mass flow metering will help ensure the selection of the proper meter for each application. It will also improve the quality of system performance estimates by providing comprehensive information on the physical phenomena and systematic errors that must be accounted for during the analysis of flow measurement data. This paper will outline the standard methods and recommended practices described in the guide titled "Flow Measurement for Electric Propulsion Systems."

  4. Remotely Guided Breast Sonography for Long-Term Space Missions: A Case Report and Discussion.

    PubMed

    Silva-Martinez, Jackelynne P; Sorice Genaro, Andreia; Wen, Hui Annie; Glauber, Naama; Russomano, Thais

    2017-12-01

    Space radiation can cause different types of cancers in crewmembers, especially during long-term space missions. To date, a complete bilateral breast ultrasound has not been performed at the International Space Station (ISS). A breast screening imaging technique could be a useful tool for early identification of breast cancer in astronauts. We hypothesized that breast ultrasound performed by a crewmember while being remotely guided by a specialist from the ground could be an essential tool for medical diagnosis in space. This project aimed to test an ultrasound screening protocol for breast tissue using real-time remotely guided telemedicine techniques. One female volunteer, with no previous medical experience, performed a self-scanned bilateral breast ultrasound exam guided by a remote sonographer. Dynamic ultrasound images were collected using a 25 mm broadband linear array transducer. To simulate fluid shift on the volunteer during microgravity, the bed was tilted -6°. Recorded ultrasound images were analyzed by radiologists, comparing the findings with a gold standard. The experiment demonstrated that real-time remotely guided sonography exam is feasible and can yield meaningful clinical results. This case study showed that remotely guided breast ultrasound can be performed and might become an important tool for diagnosis of breast cancer in space missions. The results cannot be generalized based on one subject, and additional research is warranted in this area in addition to its validation on the ISS. This technique, however, has potential for use as part of preventive medicine procedures for long-term space missions at the ISS, and eventually for human settlements on the Moon and Mars.

  5. Optimization of a multi-channel parabolic guide for the material science diffractometer STRESS-SPEC at FRM II

    NASA Astrophysics Data System (ADS)

    Rebelo Kornmeier, Joana; Ostermann, Andreas; Hofmann, Michael; Gibmeier, Jens

    2014-02-01

    Neutron strain diffractometers usually use slits to define a gauge volume within engineering samples. In this study a multi-channel parabolic neutron guide was developed to be used instead of the primary slit to minimise the loss of intensity and vertical definition of the gauge volume when using slits placed far away from the measurement position in bulky components. The major advantage of a focusing guide is that the maximum flux is not at the exit of the guide as for a slit system but at the focal point relatively far away from the exit of the guide. Monte Carlo simulations were used to optimise the multi-channel parabolic guide with respect to the instrument characteristics of the diffractometer STRESS-SPEC at the FRM II neutron source. Also the simulations are in excellent agreement with experimental measurements using the optimised multi-channel parabolic guide at the neutron diffractometer. In addition the performance of the guide was compared to the standard slit setup at STRESS-SPEC using a single bead weld sample used in earlier round robin tests for residual strain measurements.

  6. A Single-Institution Experience in Percutaneous Image-Guided Biopsy of Malignant Pleural Mesothelioma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Welch, B. T., E-mail: Welch.brian@mayo.edu; Eiken, P. W.; Atwell, T. D.

    PurposeMesothelioma has been considered a difficult pathologic diagnosis to achieve via image-guided core needle biopsy. The purpose of this study was to assess the diagnostic sensitivity of percutaneous image-guided biopsy for diagnosis of pleural mesothelioma.Materials and MethodsRetrospective review was performed to identify patients with a confirmed diagnosis of pleural mesothelioma and who underwent image-guided needle biopsy between January 1, 2002, and January 1, 2016. Thirty-two patients with pleural mesothelioma were identified and included for analysis in 33 image-guided biopsy procedures. Patient, procedural, and pathologic characteristics were recorded. Complications were characterized via standardized nomenclature [Common Terminology for Clinically Adverse Events (CTCAE)].ResultsPercutaneousmore » image-guided biopsy was associated with an overall sensitivity of 81%. No CTCAE clinically significant complications were observed. No image-guided procedures were complicated by pneumothorax or necessitated chest tube placement. No patients had tumor seeding of the biopsy tract.ConclusionPercutaneous image-guided biopsy can achieve high sensitivity for pathologic diagnosis of pleural mesothelioma with a low procedural complication rate, potentially obviating need for surgical biopsy.« less

  7. On-Orbit Prospective Echocardiography on International Space Station

    NASA Technical Reports Server (NTRS)

    Hamilton, Douglas R.; Sargsyan, Ashot E.; Martin, David; Garcia, Kathleen M.; Melton, Shannon; Feiverson, Alan; Dulchavsky, Scott A.

    2010-01-01

    A number of echocardiographic research projects and experiments have been flown on almost every space vehicle since 1970, but validation of standard methods and the determination of Space Normal cardiac function has not been reported to date. Advanced Diagnostics in Microgravity (ADUM) -remote guided echocardiographic technique provides a novel and effective approach to on-board assessment of cardiac physiology and structure using a just-in-time training algorithm and real-time remote guidance aboard the International Space Station (ISS). The validation of remotely guided echocardiographic techniques provides the procedures and protocols to perform scientific and clinical echocardiography on the ISS and the Moon. The objectives of this study were: 1.To confirm the ability of non-physician astronaut/cosmonaut crewmembers to perform clinically relevant remotely guided echocardiography using the Human Research Facility on board the ISS. 2.To compare the preflight, postflight and in-flight echocardiographic parameters commonly used in clinical medicine.

  8. A Population of Assessment Tasks

    ERIC Educational Resources Information Center

    Daro, Phil; Burkhardt, Hugh

    2012-01-01

    We propose the development of a "population" of high-quality assessment tasks that cover the performance goals set out in the "Common Core State Standards for Mathematics." The population will be published. Tests are drawn from this population as a structured random sample guided by a "balancing algorithm."

  9. Management of hypertrophic pylorus stenosis with ultrasound guided single shot epidural anaesthesia--a retrospective analysis of 20 cases.

    PubMed

    Willschke, Harald; Machata, Anette-Marie; Rebhandl, Winfried; Benkoe, Thomas; Kettner, Stephan C; Brenner, Lydia; Marhofer, Peter

    2011-02-01

    To retrospectively describe the performance of ultrasound guided thoracic epidural anaesthesia under sedation for anaesthesia management of open pyloromyotomy. Anaesthesia management for hypertrophic pylorus stenosis (HPS) is usually performed under general anaesthesia with tracheal intubation. Only a few publications describe avoidance of tracheal intubation in infants by using spinal or caudal anaesthesia. The present retrospective analysis describes the performance of ultrasound guided thoracic epidural anaesthesia under sedation for anaesthetic management of open pyloromyotomy. Twenty consecutive infants scheduled for pyloromyotomy according to the Weber-Ramstedt technique were retrospectively analysed. After sedation with nalbuphine and propofol, an ultrasound guided single shot thoracic epidural anaesthesia was performed with 0.75 ml·kg(-1) ropivacaine 0.475%. Insufficient blockade was defined as increase of HR > 15% from initial value and/or any movements at skin incision. In those cases we were prepared for rapid sequence intubation according to the departmental standard. All pyloromyotomies could be performed under single shot thoracic epidural anaesthesia and sedation. One case of moderate oxygen desaturation was treated with intermittent ventilation via face mask. Thoracic epidural anaesthesia under sedation for pyloromyotomy has been a useful technique in this retrospective series of infants suffering from HPS. In 1/20 infants short term assisted ventilation via face mask was required. Undisturbed surgery was possible in all cases. © 2010 Blackwell Publishing Ltd.

  10. Statistical Determination of the Gating Windows for Respiratory-Gated Radiotherapy Using a Visible Guiding System.

    PubMed

    Oh, Se An; Yea, Ji Woon; Kim, Sung Kyu

    2016-01-01

    Respiratory-gated radiation therapy (RGRT) is used to minimize the radiation dose to normal tissue in lung-cancer patients. Although determining the gating window in the respiratory phase of patients is important in RGRT, it is not easy. Our aim was to determine the optimal gating window when using a visible guiding system for RGRT. Between April and October 2014, the breathing signals of 23 lung-cancer patients were recorded with a real-time position management (RPM) respiratory gating system (Varian, USA). We performed statistical analysis with breathing signals to find the optimal gating window for guided breathing in RGRT. When we compared breathing signals before and after the breathing training, 19 of the 23 patients showed statistically significant differences (p < 0.05). The standard deviation of the respiration signals after breathing training was lowest for phases of 30%-70%. The results showed that the optimal gating window in RGRT is 40% (30%-70%) with respect to repeatability for breathing after respiration training with the visible guiding system. RGRT was performed with the RPM system to confirm the usefulness of the visible guiding system. The RPM system and our visible guiding system improve the respiratory regularity, which in turn should improve the accuracy and efficiency of RGRT.

  11. Endoscopic ultrasound-guided fine-needle aspiration with on-site cytopathology versus core biopsy: a comparison of both techniques performed at the same endoscopic session

    PubMed Central

    Lin, Michael; Hair, Clark D.; Green, Linda K.; Vela, Stacie A.; Patel, Kalpesh K.; Qureshi, Waqar A.; Shaib, Yasser H.

    2014-01-01

    Background: Endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) with bedside cytopathology is the gold standard for assessment of pancreatic, subepithelial, and other lesions in close proximity to the gastrointestinal tract, but it is time-consuming, has certain diagnostic limitations, and bedside cytopathology is not widely available. Aims: The goal of this study is to compare the diagnostic yield of EUS-guided FNA with on-site cytopathology and EUS-guided core biopsy. Methods: Twenty-six patients with gastrointestinal mass lesions requiring biopsy at a tertiary medical center were included in this retrospective analysis of a prospective cohort. Two core biopsies were taken using a 22 gauge needle followed by FNA guided by a bedside cytopathologist at the same endoscopic session. The diagnostic yield and test characteristics of EUS core biopsy and EUS FNA with bedside cytopathology were examined. Results: The mean number of passes was 3.2 for FNA, and the mean procedure time was 39.4 minutes. The final diagnosis was malignant in 92.3 %. Sensitivity and specificity were 83 % and 100 %, respectively, for FNA, and 91.7 % and 100 %, respectively, for core biopsy. Diagnostic accuracy was 92.3 % for FNA and 84.6 % for core biopsy. The two approaches were in agreement in 88.4 % with a kappa statistic of 0.66 (95 % confidence interval 0.33 – 0.99). Conclusions: An approach using two passes with a core biopsy needle is comparable to the current gold standard of FNA with bedside cytopathology. The performance of two core biopsies is time-efficient and could represent a good alternative to FNA with bedside cytopathology. PMID:26135096

  12. Evaluating the Performance of the IEEE Standard 1366 Method for Identifying Major Event Days

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eto, Joseph H.; LaCommare, Kristina Hamachi; Sohn, Michael D.

    IEEE Standard 1366 offers a method for segmenting reliability performance data to isolate the effects of major events from the underlying year-to-year trends in reliability. Recent analysis by the IEEE Distribution Reliability Working Group (DRWG) has found that reliability performance of some utilities differs from the expectations that helped guide the development of the Standard 1366 method. This paper proposes quantitative metrics to evaluate the performance of the Standard 1366 method in identifying major events and in reducing year-to-year variability in utility reliability. The metrics are applied to a large sample of utility-reported reliability data to assess performance of themore » method with alternative specifications that have been considered by the DRWG. We find that none of the alternatives perform uniformly 'better' than the current Standard 1366 method. That is, none of the modifications uniformly lowers the year-to-year variability in System Average Interruption Duration Index without major events. Instead, for any given alternative, while it may lower the value of this metric for some utilities, it also increases it for other utilities (sometimes dramatically). Thus, we illustrate some of the trade-offs that must be considered in using the Standard 1366 method and highlight the usefulness of the metrics we have proposed in conducting these evaluations.« less

  13. US-Guided Femoral and Sciatic Nerve Blocks for Analgesia During Endovenous Laser Ablation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yilmaz, Saim, E-mail: ysaim@akdeniz.edu.tr; Ceken, Kagan; Alimoglu, Emel

    2013-02-15

    Endovenous laser ablation may be associated with significant pain when performed under standard local tumescent anesthesia. The purpose of this study was to investigate the efficacy of femoral and sciatic nerve blocks for analgesia during endovenous ablation in patients with lower extremity venous insufficiency. During a 28-month period, ultrasound-guided femoral or sciatic nerve blocks were performed to provide analgesia during endovenous laser ablation in 506 legs and 307 patients. The femoral block (n = 402) was performed at the level of the inguinal ligament, and the sciatic block at the posterior midthigh (n = 124), by injecting a diluted lidocainemore » solution under ultrasound guidance. After the blocks, endovenous laser ablations and other treatments (phlebectomy or foam sclerotherapy) were performed in the standard fashion. After the procedures, a visual analogue pain scale (1-10) was used for pain assessment. After the blocks, pain scores were 0 or 1 (no pain) in 240 legs, 2 or 3 (uncomfortable) in 225 legs, and 4 or 5 (annoying) in 41 legs. Patients never experienced any pain higher than score 5. The statistical analysis revealed no significant difference between the pain scores of the right leg versus the left leg (p = 0.321) and between the pain scores after the femoral versus sciatic block (p = 0.7). Ultrasound-guided femoral and sciatic nerve blocks may provide considerable reduction of pain during endovenous laser and other treatments, such as ambulatory phlebectomy and foam sclerotherapy. They may make these procedures more comfortable for the patient and easier for the operator.« less

  14. The Body of Knowledge & Content Framework. Identifying the Important Knowledge Required for Productive Performance of a Plastics Machine Operator. Blow Molding, Extrusion, Injection Molding, Thermoforming.

    ERIC Educational Resources Information Center

    Society of the Plastics Industry, Inc., Washington, DC.

    Designed to guide training and curriculum development to prepare machine operators for the national certification exam, this publication identifies the important knowledge required for productive performance by a plastics machine operator. Introductory material discusses the rationale for a national standard, uses of the Body of Knowledge,…

  15. Learn, Grow, Become. TSA Edition.

    ERIC Educational Resources Information Center

    Oklahoma State Dept. of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    This revised curriculum guide contains five units that are designed to help students develop an understanding of the mission of the Technology Student Association (TSA). Each unit follows a standard format that includes some or all of these basic components: performance objectives, suggested activities, handouts, information sheets, supplements,…

  16. SNL Mechanical Computer Aided Design (MCAD) guide 2007.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moore, Brandon; Pollice, Stephanie L.; Martinez, Jack R.

    2007-12-01

    This document is considered a mechanical design best-practice guide to new and experienced designers alike. The contents consist of topics related to using Computer Aided Design (CAD) software, performing basic analyses, and using configuration management. The details specific to a particular topic have been leveraged against existing Product Realization Standard (PRS) and Technical Business Practice (TBP) requirements while maintaining alignment with sound engineering and design practices. This document is to be considered dynamic in that subsequent updates will be reflected in the main title, and each update will be published on an annual basis.

  17. MRI/US fusion-guided prostate biopsy allows for equivalent cancer detection with significantly fewer needle cores in biopsy-naive men

    PubMed Central

    Yarlagadda, Vidhush K.; Lai, Win Shun; Gordetsky, Jennifer B.; Porter, Kristin K.; Nix, Jeffrey W.; Thomas, John V.; Rais-Bahrami, Soroush

    2018-01-01

    PURPOSE We aimed to investigate the efficiency and cancer detection of magnetic resonance imaging (MRI)/ultrasonography (US) fusion-guided prostate biopsy in a cohort of biopsy-naive men compared with standard-of-care systematic extended sextant transrectal ultrasonography (TRUS)-guided biopsy. METHODS From 2014 to 2016, 72 biopsy-naive men referred for initial prostate cancer evaluation who underwent MRI of the prostate were prospectively evaluated. Retrospective review was performed on 69 patients with lesions suspicious for malignancy who underwent MRI/US fusion-guided biopsy in addition to systematic extended sextant biopsy. Biometric, imaging, and pathology data from both the MRI-targeted biopsies and systematic biopsies were analyzed and compared. RESULTS There were no significant differences in overall prostate cancer detection when comparing MRI-targeted biopsies to standard systematic biopsies (P = 0.39). Furthermore, there were no significant differences in the distribution of severity of cancers based on grade groups in cases with cancer detection (P = 0.68). However, significantly fewer needle cores were taken during the MRI/US fusion-guided biopsy compared with systematic biopsy (63% less cores sampled, P < 0.001) CONCLUSION In biopsy-naive men, MRI/US fusion-guided prostate biopsy offers equal prostate cancer detection compared with systematic TRUS-guided biopsy with significantly fewer tissue cores using the targeted technique. This approach can potentially reduce morbidity in the future if used instead of systematic biopsy without sacrificing the ability to detect prostate cancer, particularly in cases with higher grade disease. PMID:29770762

  18. C-Arm Cone-Beam CT-Guided Transthoracic Lung Core Needle Biopsy as a Standard Diagnostic Tool

    PubMed Central

    Jaconi, Marta; Pagni, Fabio; Vacirca, Francesco; Leni, Davide; Corso, Rocco; Cortinovis, Diego; Bidoli, Paolo; Bono, Francesca; Cuttin, Maria S.; Valente, Maria G.; Pesci, Alberto; Bedini, Vittorio A.; Leone, Biagio E.

    2015-01-01

    Abstract C-arm cone-beam computed tomography (CT)-guided transthoracic lung core needle biopsy (CNB) is a safe and accurate procedure for the evaluation of patients with pulmonary nodules. This article will focus on the clinical features related to CNB in terms of diagnostic performance and complication rate. Moreover, the concept of categorizing pathological diagnosis into 4 categories, which could be used for clinical management, follow-up, and quality assurance is also introduced. We retrospectively collected data regarding 375 C-arm cone-beam CT-guided CNBs from January 2010 and June 2014. Clinical and radiological variables were evaluated in terms of success or failure rate. Pathological reports were inserted in 4 homogenous groups (nondiagnostic-L1, benign-L2, malignant not otherwise specified-L3, and malignant with specific histotype-L4), defining for each category a hierarchy of suggested actions. The sensitivity, specificity, and positive and negative predictive value and accuracy for patients subjected to CNBs were of 96.8%, 100%, 100%, 100%, and 97.2%, respectively. Roughly 75% of our samples were diagnosed as malignant, with 60% lung adenocarcinoma diagnoses. Molecular analyses were performed on 85 malignant samples to verify applicability of targeted therapy. The rate of “nondiagnostic” samples was 12%. C-arm cone-beam CT-guided transthoracic lung CNB can represent the gold standard for the diagnostic evaluation of pulmonary nodules. A clinical and pathological multidisciplinary evaluation of CNBs was needed in terms of integration of radiological, histological, and oncological data. This approach provided exceptional performances in terms of specificity, positive and negative predictive values; sensitivity in our series was lower compared with other large studies, probably due to the application of strong criteria of adequacy for CNBs (L1 class rate). The satisfactory rate of collected material was evaluated not only in terms of merely diagnostic performances but also for predictive results by molecular analysis. PMID:25816042

  19. C-arm cone-beam CT-guided transthoracic lung core needle biopsy as a standard diagnostic tool: an observational study.

    PubMed

    Jaconi, Marta; Pagni, Fabio; Vacirca, Francesco; Leni, Davide; Corso, Rocco; Cortinovis, Diego; Bidoli, Paolo; Bono, Francesca; Cuttin, Maria S; Valente, Maria G; Pesci, Alberto; Bedini, Vittorio A; Leone, Biagio E

    2015-03-01

    C-arm cone-beam computed tomography (CT)-guided transthoracic lung core needle biopsy (CNB) is a safe and accurate procedure for the evaluation of patients with pulmonary nodules. This article will focus on the clinical features related to CNB in terms of diagnostic performance and complication rate. Moreover, the concept of categorizing pathological diagnosis into 4 categories, which could be used for clinical management, follow-up, and quality assurance is also introduced. We retrospectively collected data regarding 375 C-arm cone-beam CT-guided CNBs from January 2010 and June 2014. Clinical and radiological variables were evaluated in terms of success or failure rate. Pathological reports were inserted in 4 homogenous groups (nondiagnostic--L1, benign--L2, malignant not otherwise specified--L3, and malignant with specific histotype--L4), defining for each category a hierarchy of suggested actions. The sensitivity, specificity, and positive and negative predictive value and accuracy for patients subjected to CNBs were of 96.8%, 100%, 100%, 100%, and 97.2%, respectively. Roughly 75% of our samples were diagnosed as malignant, with 60% lung adenocarcinoma diagnoses. Molecular analyses were performed on 85 malignant samples to verify applicability of targeted therapy. The rate of "nondiagnostic" samples was 12%. C-arm cone-beam CT-guided transthoracic lung CNB can represent the gold standard for the diagnostic evaluation of pulmonary nodules. A clinical and pathological multidisciplinary evaluation of CNBs was needed in terms of integration of radiological, histological, and oncological data. This approach provided exceptional performances in terms of specificity, positive and negative predictive values; sensitivity in our series was lower compared with other large studies, probably due to the application of strong criteria of adequacy for CNBs (L1 class rate). The satisfactory rate of collected material was evaluated not only in terms of merely diagnostic performances but also for predictive results by molecular analysis.

  20. Novel needle guide reduces time to perform ultrasound-guided femoral nerve catheter placement: A randomised controlled trial.

    PubMed

    Turan, Alparslan; Babazade, Rovnat; Elsharkawy, Hesham; Esa, Wael Ali Sakr; Maheshwari, Kamal; Farag, Ehab; Zimmerman, Nicole M; Soliman, Loran Mounir; Sessler, Daniel I

    2017-03-01

    Ultrasound-guided nerve blocks have become the standard when performing regional nerve blocks in anaesthesia. Infiniti Plus (CIVCO Medical Solutions, Kalona, Iowa, USA) is a needle guide that has been recently developed to help clinicians in performing ultrasound-guided nerve blocks. We tested the hypothesis that femoral nerve catheter placement carried out with the Infiniti Plus needle guide will be quicker to perform than without the Infiniti Plus. Secondary aims were to assess whether the Infiniti Plus needle guide decreased the number of block attempts and also whether it improved needle visibility. A randomised, controlled trial. Cleveland Clinic, Cleveland, Ohio, USA. We enrolled adult patients having elective total knee arthroplasty with a femoral nerve block and femoral nerve catheter. Patients, who were pregnant or those who had preexisting neuropathy involving the surgical limb, coagulopathy, infection at the block site or allergy to local anaesthetics were excluded. Patients were randomised into two groups to receive the ultrasound-guided femoral nerve catheter placement with or without the Infiniti Plus needle guide. The time taken to place the femoral nerve catheter, the number of attempts, the success rate and needle visibility were recorded. We used an overall α of 0.05 for both the primary and secondary analyses; the secondary analyses were Bonferroni corrected to control for multiple comparisons. The median (interquartile range Q1 to Q3) time to perform the femoral nerve catheter placement was 118 (100 to 150) s with Infiniti Plus and 177 (130 to 236) s without Infiniti Plus. Infiniti Plus significantly reduced the time spent performing femoral nerve catheterisation, with estimated ratio of means [(95% confidence interval), P value] of 0.67 [(0.60 to 0.75), P < 0.001] with Infiniti Plus compared with no Infiniti Plus. However, Infiniti Plus had no effect on the odds of a successful femoral nerve catheter placement, number of attempts or percentage of perfect needle visibility. We found that the use of Infiniti Plus decreased the median time to successfully place a femoral nerve catheter by 33% compared with not using Infiniti Plus. This difference may be more apparent to clinicians undertaking this procedure less often or by those in training as our team was very experienced, had been trained in the technique and was working in a hospital with a large caseload. Clinicaltrials.gov identifier: NCT02080481.

  1. UIAGM Ropehandling Techniques.

    ERIC Educational Resources Information Center

    Cloutier, K. Ross

    The Union Internationale des Associations des Guides de Montagne's (UIAGM) rope handling techniques are intended to form the standard for guiding ropework worldwide. These techniques have become the legal standard for instructional institutions and commercial guiding organizations in UIAGM member countries: Austria, Canada, France, Germany, Great…

  2. Educational Indicators: A Guide for Policymakers. CPRE Occasional Paper Series.

    ERIC Educational Resources Information Center

    Oakes, Jeannie

    An educational indicator is a statistic revealing something about the education system's health or performance. Indicators must meet certain substantive and technical standards that define the kind of information they should provide and the features they should measure. There are two types of statistical indicators. Whereas single statistics…

  3. 30 CFR 715.200 - Interpretative rules related to general performance standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... a qualified soil scientist or agronomist, may be obtained from any one or a combination of the following sources: (i) U.S. Department of Agriculture Soil Conservation Service published data based on established soil series; (ii) U.S. Department of Agriculture Soil Conservation Service Technical Guides; (iii...

  4. 30 CFR 816.200 - Interpretative rules related to general performance standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... demonstrate that the resulting soil medium is equal to or more suitable for sustaining revegetation than the...: (i) U.S. Department of Agriculture Soil Conservation Service published data based on established soil series; (ii) U.S. Department of Agriculture Soil Conservation Service Technical Guides; (iii) State...

  5. 30 CFR 816.200 - Interpretative rules related to general performance standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... demonstrate that the resulting soil medium is equal to or more suitable for sustaining revegetation than the...: (i) U.S. Department of Agriculture Soil Conservation Service published data based on established soil series; (ii) U.S. Department of Agriculture Soil Conservation Service Technical Guides; (iii) State...

  6. 30 CFR 817.200 - Interpretative rules related to general performance standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... demonstrate that the resulting soil medium is equal to or more suitable for sustaining revegetation than the...: (i) U.S. Department of Agriculture Soil Conservation Service published data based on established soil series; (ii) U.S. Department of Agriculture Soil Conservation Service Technical Guides; (iii) State...

  7. 30 CFR 817.200 - Interpretative rules related to general performance standards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... demonstrate that the resulting soil medium is equal to or more suitable for sustaining revegetation than the...: (i) U.S. Department of Agriculture Soil Conservation Service published data based on established soil series; (ii) U.S. Department of Agriculture Soil Conservation Service Technical Guides; (iii) State...

  8. 30 CFR 715.200 - Interpretative rules related to general performance standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... a qualified soil scientist or agronomist, may be obtained from any one or a combination of the following sources: (i) U.S. Department of Agriculture Soil Conservation Service published data based on established soil series; (ii) U.S. Department of Agriculture Soil Conservation Service Technical Guides; (iii...

  9. 30 CFR 817.200 - Interpretative rules related to general performance standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... demonstrate that the resulting soil medium is equal to or more suitable for sustaining revegetation than the...: (i) U.S. Department of Agriculture Soil Conservation Service published data based on established soil series; (ii) U.S. Department of Agriculture Soil Conservation Service Technical Guides; (iii) State...

  10. 30 CFR 817.200 - Interpretative rules related to general performance standards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... demonstrate that the resulting soil medium is equal to or more suitable for sustaining revegetation than the...: (i) U.S. Department of Agriculture Soil Conservation Service published data based on established soil series; (ii) U.S. Department of Agriculture Soil Conservation Service Technical Guides; (iii) State...

  11. 30 CFR 715.200 - Interpretative rules related to general performance standards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... a qualified soil scientist or agronomist, may be obtained from any one or a combination of the following sources: (i) U.S. Department of Agriculture Soil Conservation Service published data based on established soil series; (ii) U.S. Department of Agriculture Soil Conservation Service Technical Guides; (iii...

  12. 30 CFR 715.200 - Interpretative rules related to general performance standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... a qualified soil scientist or agronomist, may be obtained from any one or a combination of the following sources: (i) U.S. Department of Agriculture Soil Conservation Service published data based on established soil series; (ii) U.S. Department of Agriculture Soil Conservation Service Technical Guides; (iii...

  13. 30 CFR 715.200 - Interpretative rules related to general performance standards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... a qualified soil scientist or agronomist, may be obtained from any one or a combination of the following sources: (i) U.S. Department of Agriculture Soil Conservation Service published data based on established soil series; (ii) U.S. Department of Agriculture Soil Conservation Service Technical Guides; (iii...

  14. 30 CFR 816.200 - Interpretative rules related to general performance standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... demonstrate that the resulting soil medium is equal to or more suitable for sustaining revegetation than the...: (i) U.S. Department of Agriculture Soil Conservation Service published data based on established soil series; (ii) U.S. Department of Agriculture Soil Conservation Service Technical Guides; (iii) State...

  15. 30 CFR 816.200 - Interpretative rules related to general performance standards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... demonstrate that the resulting soil medium is equal to or more suitable for sustaining revegetation than the...: (i) U.S. Department of Agriculture Soil Conservation Service published data based on established soil series; (ii) U.S. Department of Agriculture Soil Conservation Service Technical Guides; (iii) State...

  16. 30 CFR 816.200 - Interpretative rules related to general performance standards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... demonstrate that the resulting soil medium is equal to or more suitable for sustaining revegetation than the...: (i) U.S. Department of Agriculture Soil Conservation Service published data based on established soil series; (ii) U.S. Department of Agriculture Soil Conservation Service Technical Guides; (iii) State...

  17. 30 CFR 817.200 - Interpretative rules related to general performance standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... demonstrate that the resulting soil medium is equal to or more suitable for sustaining revegetation than the...: (i) U.S. Department of Agriculture Soil Conservation Service published data based on established soil series; (ii) U.S. Department of Agriculture Soil Conservation Service Technical Guides; (iii) State...

  18. Faculty Development Manual for the School of Allied Health Sciences, University of Texas Medical Branch at Galveston.

    ERIC Educational Resources Information Center

    Texas Univ., Galveston. Medical Branch.

    The contents of this guide, adopted for a one-year pilot study, include: standard operating procedures for the faculty development/effectiveness document (performance and evaluation contract); instructions and forms for evaluating effectiveness in teaching, administrative duties, and professional activities; and a faculty…

  19. The Leader's Guide to Standards: A Blueprint for Educational Equity and Excellence. The Jossey-Bass Education Series.

    ERIC Educational Resources Information Center

    Reeves, Douglas B.

    This book offers instructions for school principals, assistant principals, teachers, and district-level administrators for building a comprehensive accountability system that focuses on leadership skills. It presents recommendations for assessing and nurturing teacher performance, setting up balanced assessment and accountability policies, and…

  20. Assessing District Support for Leadership Development: Asking the Right Questions.

    ERIC Educational Resources Information Center

    Snow-Renner, Ravay

    This document provides guiding questions and a process for school district personnel to assess the district's organizational capacity for supporting strong educational leaders in a standards-based system. These questions reflect the most recent research literature about leadership and its optimal organizational supports in high-performing school…

  1. High Voltage Guided Pulmonary Vein Isolation in Paroxysmal Atrial Fibrillation.

    PubMed

    Boles, Usama; Gul, Enes E; Enriquez, Andres; Lee, Howard; Riegert, Dave; Andres, Adrian; Baranchuk, Adrian; Redfearn, Damian; Glover, Benedict; Simpson, Chris; Abdollah, Hoshiar; Michael, Kevin

    2017-01-01

    Ablation of the pulmonary vein (PV) antrum using an electroanatomic mapping system is standard of care for point-by-point pulmonary vein isolation (PVI). Focused ablation at critical areas is more likely to achieve intra-procedural PV isolation and decrease the likelihood for reconnection and recurrence of atrial fibrillation (AF). Therefore this prospective pilot study is to investigate the short-term outcome of a voltage-guided circumferential PV ablation (CPVA) strategy. We recruited patients with a history of paroxysmal atrial fibrillation (AF). The EnSite NavX system (St. Jude Medical, St Paul, Minnesota, USA) was employed to construct a three-dimensional geometry of the left atrium (LA) and voltage map. CPVA was performed; with radiofrequency (RF) targeting sites of highest voltage first in a sequential clockwise fashion then followed by complete the gaps in circumferential ablation. Acute and short-term outcomes were compared to a control group undergoing conventional standard CPVA using the same 3D system. Follow-up was scheduled at 3, 6 and 12 months. Thirty-four paroxysmal AF patients with a mean age of 40 years were included. Fourteen patients (8 male) underwent voltage mapping and 20 patients underwent empirical, non-voltage guided standard CPVA. A mean of 54 ± 12 points per PV antrum were recorded. Mean voltage for right and left PVs antra were 1.7±0.1 mV and 1.9±0.2 mV, respectively. There was a trend towards reduced radiofrequency time (40.9±17.4 vs. 48.1±15.5 mins; p=0.22). Voltage-guided CPVA is a promising strategy in targeting critical points for PV isolation with a lower trend of AF recurrence compared with a standard CPVA in short-term period. Extended studies to confirm these findings are warranted.

  2. Optimum Tilt Angle of Flow Guide in Steam Turbine Exhaust Hood Considering the Effect of Last Stage Flow Field

    NASA Astrophysics Data System (ADS)

    CAO, Lihua; LIN, Aqiang; LI, Yong; XIAO, Bin

    2017-07-01

    Heat transfer and vacuum in condenser are influenced by the aerodynamic performance of steam turbine exhaust hood. The current research on exhaust hood is mainly focused on analyzing flow loss and optimal design of its structure without consideration of the wet steam condensing flow and the exhaust hood coupled with the front and rear parts. To better understand the aerodynamic performance influenced by the tilt angle of flow guide inside a diffuser, taking a 600 MW steam turbine as an example, a numerical simulator CFX is adopted to solve compressible three-dimensional (3D) Reynolds time-averaged N-S equations and standard k- ɛ turbulence model. And the exhaust hood flow field influenced by different tilt angles of flow guide is investigated with consideration of the wet steam condensing flow and the exhaust hood coupled with the last stage blades and the condenser throat. The result shows that the total pressure loss coefficient and the static pressure recovery coefficient of exhaust hood change regularly and monotonously with the gradual increase of tilt angle of flow guide. When the tilt angle of flow guide is within the range of 30° to 40°, the static pressure recovery coefficient is in the range of 15.27% to 17.03% and the total pressure loss coefficient drops to approximately 51%, the aerodynamic performance of exhaust hood is significantly improved. And the effective enthalpy drop in steam turbine increases by 0.228% to 0.274%. It is feasible to obtain a reasonable title angle of flow guide by the method of coupling the last stage and the condenser throat to exhaust hood in combination of the wet steam model, which provides a practical guidance to flow guide transformation and optimal design in exhaust hood.

  3. Through the Past Decade: How Advanced Energy Design Guides have influenced the Design Industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Bing; Athalye, Rahul A.

    Advanced Energy Design Guides (AEDGs) were originally developed intended to provide a simple approach to building professionals seeking energy efficient building designs better than ASHRAE Standard 90.1. Since its first book was released in 2004, the AEDG series provided inspiration for the design industry and were seen by designers as a starting point for buildings that wished to go beyond minimum codes and standards. In addition, U.S. Department of Energy’s successful Commercial Building Partnerships (CBP) program leveraged many of the recommendations from the AEDGs to achieve 50% energy savings over ASHRAE Standard 90.1-2004 for prototypical designs of large commercial entitiesmore » in the retail, banking and lodging sectors. Low-energy technologies and strategies developed during the CBP process have been applied by commercial partners throughout their national portfolio of buildings. Later, the AEDGs served as the perfect platform for both Standard 90.1 and ASHRAE’s high performance buildings standard, Standard 189.1. What was high performance a few years ago, however, has become minimum code today. Indeed, most of the prescriptive envelope component requirements in ASHRAE Standard 90.1-2013 are values recommended in the 50% AEDGs several years ago. Similarly, AEDG strategies and recommendations have penetrated the lighting and HVAC sections of both Standard 189.1 and Standard 90.1. Finally, as we look to the future of codes and standards, the AEDGs are serving as a blueprint for how minimum code requirements could be expressed. By customizing codes to specific building types, design strategies tailored for individual buildings could be prescribed as minimum code, just like in the AEDGs. This paper describes the impact that AEDGs have had over the last decade on the design industry and how they continue to influence the future of codes and Standards. From design professionals to code officials, everyone in the building industry has been affected by the AEDGs.« less

  4. Intrarater repeatability of shade selections with two shade guides.

    PubMed

    Hammad, Ihab A

    2003-01-01

    Color research has shown that shade guides do not always represent the color of natural teeth. Moreover, visual evaluation has been found to be unreliable and inconsistent. This investigation evaluated the effects of 2 shade guides on the intrarater repeatability (reliability) of prosthodontists and general practitioners with regard to shade selection. Ten prosthodontists and ten general practitioners (all men, 35-45 years old) with an average practice experience of 14 years participated in this study. Examiners were tested to eliminate color blindness. Each clinician used Vita Lumin Vacuum and Vitapan 3D-Master shade guides to determine the shades of the maxillary right canines of 20 patients following a standard protocol. The identification codes of the shade tabs were masked to prevent shade memory. All teeth were polished before each shade selection, and the selection process was standardized for controlled lighting and procedures. Shade selections were randomly repeated 1 month later by the same practitioners on the same group of patients in accordance with the same shade-selection protocol. Analysis of variance and t tests for individual comparisons among means were performed (P<.05). Significant interactions were found between the effects of shade guide system and specialty training on intrarater repeatability (P<.0001, analysis of variance). The intrarater repeatability of prosthodontists was significantly higher than that of general practitioners when the Vita Lumin Vacuum shade guide was used (P<.0001, t test). Use of the Vitapan 3D-Master shade guide significantly improved the intrarater repeatability of general practitioners compared with the Vita Lumin Vacuum shade guide (P<.0005). This improvement was not significant, however, among prosthodontists (P=.2861). Within the limitations of this study, the prosthodontists demonstrated superior intrarater repeatability in shade selection, especially when the Vita Lumin Vacuum shade guide was used. Use of the Vitapan 3D-Master shade guide notably improved intrarater repeatability among the general practitioners.

  5. Dynamic and Transient Performance of Turbofan/Turboshaft Convertible Engine With Variable Inlet Guide Vanes

    NASA Technical Reports Server (NTRS)

    McArdle, Jack G.; Barth, Richard L.; Wenzel, Leon M.; Biesiadny, Thomas J.

    1996-01-01

    A convertible engine called the CEST TF34, using the variable inlet guide vane method of power change, was tested on an outdoor stand at the NASA Lewis Research Center with a waterbrake dynamometer for the shaft load. A new digital electronic system, in conjunction with a modified standard TF34 hydromechanical fuel control, kept engine operation stable and safely within limits. All planned testing was completed successfully. Steady-state performance and acoustic characteristics were reported previously and are referenced. This report presents results of transient and dynamic tests. The transient tests measured engine response to several rapid changes in thrust and torque commands at constant fan (shaft) speed. Limited results from dynamic tests using the pseudorandom binary noise technique are also presented. Performance of the waterbrake dynamometer is discussed in an appendix.

  6. Solar Access to Public Capital (SAPC) Working Group: Best Practices in PV System Installation; Version 1.0, March 2015; Period of Performance, October 2014 - September 2015

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doyle, C.; Truitt, A.; Inda, D.

    The following Photovoltaics Installation Best Practices Guide is one of several work products developed by the Solar Access to Public Capital (SAPC) working group, which works to open capital market investment. SAPC membership includes over 450 leading solar developers, financiers and capital managers, law firms, rating agencies, accounting and engineering firms, and other stakeholders engaged in solar asset deployment. SAPC activities are directed toward foundational elements necessary to pool project cash flows into tradable securities: standardization of power purchase and lease contracts for residential and commercial end customers; development of performance and credit data sets to facilitate investor due diligencemore » activities; comprehension of risk perceived by rating agencies; and the development of best practice guides for PV system installation and operations and maintenance (O&M) in order to encourage high-quality system deployment and operation that may improve lifetime project performance and energy production. This PV Installation Best Practices Guide was developed through the SAPC Installation Best Practices subcommittee, a subgroup of SAPC comprised of a wide array of solar industry leaders in numerous fields of practice. The guide was developed over roughly one year and eight months of direct engagement by the subcommittee and two working group comment periods.« less

  7. International Standards for Properties and Performance of Advanced Ceramics - 30 years of Excellence

    NASA Technical Reports Server (NTRS)

    Jenkins, Michael G.; Salem, Jonathan A.; Helfinstine, John; Quinn, George D.; Gonczy, Stephen T.

    2016-01-01

    Mechanical and physical properties/performance of brittle bodies (e.g., advanced ceramics and glasses) can be difficult to measure correctly unless the proper techniques are used. For three decades, ASTM Committee C28 on Advanced Ceramics, has developed numerous full-consensus standards (e.g., test methods, practices, guides, terminology) to measure various properties and performance of a monolithic and composite ceramics and coatings that, in some cases, may be applicable to glasses. These standards give the "what, how, how not, why, why not, etc." for many mechanical, physical, thermal, properties and performance of advanced ceramics. Use of these standards provides accurate, reliable, repeatable and complete data. Involvement in ASTM Committee C28 has included users, producers, researchers, designers, academicians, etc. who write, continually update, and validate through round robin test programmes, more than 45 standards in the 30 years since the Committee's inception in 1986. Included in this poster is a pictogram of the ASTM Committee C28 standards and how to obtain them either as i) individual copies with full details or ii) a complete collection in one volume. A listing of other ASTM committees of interest is included. In addition, some examples of the tangible benefits of standards for advanced ceramics are employed to demonstrate their practical application.

  8. Emergency Medical Dispatch. National Standard Curriculum. Instructor Guide. Trainee Guide.

    ERIC Educational Resources Information Center

    National Highway Traffic Safety Administration (DOT), Washington, DC.

    This guide contains all instructor materials and requirements for the National Highway Traffic Safety Administration (NHTSA), Emergency Medical Dispatch (EMD) National Standard Curriculum. It includes lesson plans, instructional aids, and tools and supporting information designed to elevate trained and experienced public safety telecommunicators…

  9. The Development of a Quality Management Framework for Evaluating Medical Device Reprocessing Practice in Healthcare Facilities.

    PubMed

    Lorv, Bailey; Horodyski, Robin; Welton, Cynthia; Vail, John; Simonetto, Luca; Jokanovic, Danilo; Sharma, Richa; Mahoney, Angela Rea; Savoy-Bird, Shay; Bains, Shalu

    2017-01-01

    There is increasing awareness of the importance of medical device reprocessing (MDR) for the provision of safe patient care. Although industry service standards are available to guide MDR practices, there remains a lack of published key performance indicators (KPIs) and targets that are necessary to evaluate MDR quality for feedback and improvement. This article outlines the development of an initial framework that builds on established guidelines and includes service standards, KPIs and targets for evaluating MDR operations. This framework can support healthcare facilities in strengthening existing practices and enables a platform for collaboration towards better MDR performance management.

  10. Cost-utility analysis of great saphenous vein ablation with radiofrequency, foam and surgery in the emerging health-care setting of Thailand.

    PubMed

    Siribumrungwong, Boonying; Noorit, Pinit; Wilasrusmee, Chumpon; Leelahavarong, Pattara; Thakkinstian, Ammarin; Teerawattananon, Yot

    2016-09-01

    To conduct economic evaluations of radiofrequency ablation, ultrasound-guided foam sclerotherapy and surgery for great saphenous vein ablation. A cost-utility and cohort analysis from societal perspective was performed to estimate incremental cost-effectiveness ratio. Transitional probabilities were from meta-analysis. Direct medical, direct non-medical, indirect costs, and utility were from standard Thai costings and cohort. Probabilistic sensitivity analysis was performed to assess parameter uncertainties. Seventy-seven patients (31 radiofrequency ablation, 19 ultrasound-guided foam sclerotherapy, and 27 surgeries) were enrolled from October 2011 to February 2013. Compared with surgery, radiofrequency ablation costed 12,935 and 20,872 Baht higher, whereas ultrasound-guided foam sclerotherapy costed 6159 lower and 1558 Bath higher for outpatient and inpatient, respectively. At one year, radiofrequency ablation had slightly lower quality-adjusted life-year, whereas ultrasound-guided foam sclerotherapy yielded additional 0.025 quality-adjusted life-year gained. Because of costing lower and greater quality-adjusted life-year than other compared alternatives, outpatient ultrasound-guided foam sclerotherapy was an option being dominant. Probabilistic sensitivity analysis resulted that at the Thai ceiling threshold of 160,000 Baht/quality-adjusted life-year gained, ultrasound-guided foam sclerotherapy had chances of 0.71 to be cost-effective. Ultrasound-guided foam sclerotherapy seems to be cost-effective for treating great saphenous vein reflux compared to surgery in Thailand at one-year results. © The Author(s) 2015.

  11. Preclinical Feasibility of a Technology Framework for MRI-guided Iliac Angioplasty

    PubMed Central

    Rube, Martin A.; Fernandez-Gutierrez, Fabiola; Cox, Benjamin F.; Holbrook, Andrew B.; Houston, J. Graeme; White, Richard D.; McLeod, Helen; Fatahi, Mahsa; Melzer, Andreas

    2015-01-01

    Purpose Interventional MRI has significant potential for image guidance of iliac angioplasty and related vascular procedures. A technology framework with in-room image display, control, communication and MRI-guided intervention techniques was designed and tested for its potential to provide safe, fast and efficient MRI-guided angioplasty of the iliac arteries. Methods A 1.5T MRI scanner was adapted for interactive imaging during endovascular procedures using new or modified interventional devices such as guidewires and catheters. A perfused vascular phantom was used for testing. Pre-, intra- and post-procedural visualization and measurement of vascular morphology and flow was implemented. A detailed analysis of X-Ray fluoroscopic angiography workflow was conducted and applied. Two interventional radiologists and one physician in training performed 39 procedures. All procedures were timed and analyzed. Results MRI-guided iliac angioplasty procedures were successfully performed with progressive adaptation of techniques and workflow. The workflow, setup and protocol enabled a reduction in table time for a dedicated MRI-guided procedure to 6 min 33 s with a mean procedure time of 9 min 2 s, comparable to the mean procedure time of 8 min 42 s for the standard X-Ray guided procedure. Conclusions MRI-guided iliac vascular interventions were found to be feasible and practical using this framework and optimized workflow. In particular the real-time flow analysis was found to be helpful for pre- and post-interventional assessments. Design optimization of the catheters and in vivo experiments are required before clinical evaluation. PMID:25102933

  12. A Guide for Parents and Families about What Your 6th Grader Should Be Learning in School This Year. Don't Fail Your Children.

    ERIC Educational Resources Information Center

    South Carolina State Education Oversight Committee, Columbia.

    This guide shares information about the South Carolina Curriculum Standards with parents. The standards outline state requirements for children's learning, and what students across the state should be able to do in certain subjects. The guide lists seven key reasons for parents to be aware of the new curriculum standards, and then presents a…

  13. A Guide for Parents and Families about What Your 5th Grader Should Be Learning in School This Year. Don't Fail Your Children.

    ERIC Educational Resources Information Center

    South Carolina State Education Oversight Committee, Columbia.

    This guide shares information about the South Carolina Curriculum Standards with parents. The standards outline state requirements for children's learning, and what students across the state should be able to do in certain subjects. The guide lists seven key reasons for parents to be aware of the new curriculum standards, and then presents a…

  14. A Guide for Parents and Families about What Your Kindergartner Should Be Learning in School This Year. Don't Fail Your Children.

    ERIC Educational Resources Information Center

    South Carolina State Education Oversight Committee, Columbia.

    This guide shares information about the South Carolina Curriculum Standards with parents. The standards outline state requirements for children's learning, and what students across the state should be able to do in certain subjects. The guide lists seven key reasons for parents to be aware of the new curriculum standards, and then presents a…

  15. A Guide for Parents and Families about What Your 9th Grader Should Be Learning in School This Year. Don't Fail Your Children.

    ERIC Educational Resources Information Center

    South Carolina State Education Oversight Committee, Columbia.

    This guide shares information about the South Carolina Curriculum Standards with parents. The standards outline state requirements for children's learning, and what students across the state should be able to do in certain subjects. The guide lists seven key reasons for parents to be aware of the new curriculum standards, and then presents a…

  16. A Guide for Parents and Families about What Your 7th Grader Should Be Learning in School This Year. Don't Fail Your Children.

    ERIC Educational Resources Information Center

    South Carolina State Education Oversight Committee, Columbia.

    This guide shares information about the South Carolina Curriculum Standards with parents. The standards outline state requirements for children's learning, and what students across the state should be able to do in certain subjects. The guide lists seven key reasons for parents to be aware of the new curriculum standards, and then presents a…

  17. A Guide for Parents and Families about What Your 11th Grader Should Be Learning in School This Year. Don't Fail Your Children.

    ERIC Educational Resources Information Center

    South Carolina State Education Oversight Committee, Columbia.

    This guide shares information about the South Carolina Curriculum Standards with parents. The standards outline state requirements for children's learning, and what students across the state should be able to do in certain subjects. The guide lists seven key reasons for parents to be aware of the new curriculum standards, and then presents a…

  18. A Guide for Parents and Families about What Your 2nd Grader Should Be Learning in School This Year. Don't Fail Your Children.

    ERIC Educational Resources Information Center

    South Carolina State Education Oversight Committee, Columbia.

    This guide shares information about the South Carolina Curriculum Standards with parents. The standards outline state requirements for children's learning, and what students across the state should be able to do in certain subjects. The guide lists seven key reasons for parents to be aware of the new curriculum standards, and then presents a…

  19. A Guide for Parents and Families about What Your 10th Grader Should Be Learning in School This Year. Don't Fail Your Children.

    ERIC Educational Resources Information Center

    South Carolina State Education Oversight Committee, Columbia.

    This guide shares information about the South Carolina Curriculum Standards with parents. The standards outline state requirements for children's learning, and what students across the state should be able to do in certain subjects. The guide lists seven key reasons for parents to be aware of the new curriculum standards, and then presents a…

  20. A Guide for Parents and Families about What Your 1st Grader Should Be Learning in School This Year. Don't Fail Your Children.

    ERIC Educational Resources Information Center

    South Carolina State Education Oversight Committee, Columbia.

    This guide shares information about the South Carolina Curriculum Standards with parents. The standards outline state requirements for children's learning, and what students across the state should be able to do in certain subjects. The guide lists seven key reasons for parents to be aware of the new curriculum standards, and then presents a…

  1. A Guide for Parents and Families about What Your 8th Grader Should Be Learning in School This Year. Don't Fail Your Children.

    ERIC Educational Resources Information Center

    South Carolina State Education Oversight Committee, Columbia.

    This guide shares information about the South Carolina Curriculum Standards with parents. The standards outline state requirements for children's learning, and what students across the state should be able to do in certain subjects. The guide lists seven key reasons for parents to be aware of the new curriculum standards, and then presents a…

  2. A Guide for Parents and Families about What Your 4th Grader Should Be Learning in School This Year. Don't Fail Your Children.

    ERIC Educational Resources Information Center

    South Carolina State Education Oversight Committee, Columbia.

    This guide shares information about the South Carolina Curriculum Standards with parents. The standards outline state requirements for children's learning, and what students across the state should be able to do in certain subjects. The guide lists seven key reasons for parents to be aware of the new curriculum standards, and then presents a…

  3. Procedures and Standards for Residential Ventilation System Commissioning: An Annotated Bibliography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stratton, J. Chris; Wray, Craig P.

    2013-04-01

    Beginning with the 2008 version of Title 24, new homes in California must comply with ANSI/ASHRAE Standard 62.2-2007 requirements for residential ventilation. Where installed, the limited data available indicate that mechanical ventilation systems do not always perform optimally or even as many codes and forecasts predict. Commissioning such systems when they are installed or during subsequent building retrofits is a step towards eliminating deficiencies and optimizing the tradeoff between energy use and acceptable IAQ. Work funded by the California Energy Commission about a decade ago at Berkeley Lab documented procedures for residential commissioning, but did not focus on ventilation systems.more » Since then, standards and approaches for commissioning ventilation systems have been an active area of work in Europe. This report describes our efforts to collect new literature on commissioning procedures and to identify information that can be used to support the future development of residential-ventilation-specific procedures and standards. We recommend that a standardized commissioning process and a commissioning guide for practitioners be developed, along with a combined energy and IAQ benefit assessment standard and tool, and a diagnostic guide for estimating continuous pollutant emission rates of concern in residences (including a database that lists emission test data for commercially-available labeled products).« less

  4. Diversity of assessing circulating tumor cells (CTCs) emphasizes need for standardization: a CTC Guide to design and report trials.

    PubMed

    Bünger, S; Zimmermann, M; Habermann, J K

    2015-09-01

    Hematogenous spreading of tumor cells from primary tumors is a crucial step in the cascade to metastasis, the latter being the most limiting factor for patients' survival prognosis. Therefore, circulating tumor cells (CTCs) have become a field of intensive research. However, the process of isolation and identification of CTCs lacks standardization. This article presents an overview of 71 CTC studies reported in PUBMED since 2000 and focusing on colorectal cancer. These studies are evaluated regarding standardization of CTC isolation and identification, marker proteins used, study population and blood sample quality management, clinical performance, and quality measures. Overall, standardization of CTC assessment seems insufficient. Thus, comparability of CTC studies is hampered and results should be interpreted carefully. We here propose a standardized CTC guideline (CTC Guide) to prospectively design and report studies/trials in a harmonized form. Despite the current interstudy heterogeneity, the data indicate that CTC detection is of clinical relevance and CTCs should be considered as a surrogate prognostic marker. Many studies indicate the high potential for CTCs as prognostic markers, e.g., in colorectal cancer treatment. However, standardized, large-scale multicenter validation studies are still needed to pave the way for clinical implementation of CTC detection that could ameliorate individualized medicine regimes.

  5. Ultrasound-guided versus computed tomography-scan guided biopsy of pleural-based lung lesions

    PubMed Central

    Khosla, Rahul; McLean, Anna W; Smith, Jessica A

    2016-01-01

    Background: Computed tomography (CT) guided biopsies have long been the standard technique to obtain tissue from the thoracic cavity and is traditionally performed by interventional radiologists. Ultrasound (US) guided biopsy of pleural-based lesions, performed by pulmonologists is gaining popularity and has the advantage of multi-planar imaging, real-time technique, and the absence of radiation exposure to patients. In this study, we aim to determine the diagnostic accuracy, the time to diagnosis after the initial consult placement, and the complications rates between the two different modalities. Methods: A retrospective study of electronic medical records was done of patients who underwent CT-guided biopsies and US-guided biopsies for pleural-based lesions between 2005 and 2014 and the data collected were analyzed for comparing the two groups. Results: A total of 158 patients underwent 162 procedures during the study period. 86 patients underwent 89 procedures in the US group, and 72 patients underwent 73 procedures in the CT group. The overall yield in the US group was 82/89 (92.1%) versus 67/73 (91.8%) in the CT group (P = 1.0). Average days to the procedure was 7.2 versus 17.5 (P = 0.00001) in the US and CT group, respectively. Complication rate was higher in CT group 17/73 (23.3%) versus 1/89 (1.1%) in the US group (P < 0.0001). Conclusions: For pleural-based lesions the diagnostic accuracy of US guided biopsy is similar to that of CT-guided biopsy, with a lower complication rate and a significantly reduced time to the procedure. PMID:27625440

  6. System administrator`s guide to CDPS. Version 1.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Didier, B.T.; Portwood, M.H.

    The System Administrator`s Guide to CDPS is intended for those responsible for setting up and maintaining the hardware and software of a Common Mapping Standard (CMS) Date Production System (CDPS) installation. This guide assists the system administrator in performing typical administrative functions. It is not intended to replace the Ultrix Documentation Set that should be available for a DCPS installation. The Ultrix Documentation Set will be required to provide details on referenced Ultrix commands as well as procedures for performing Ultrix maintenance functions. There are six major sections in this guide. Section 1 introduces the system administrator to CDPS andmore » describes the assumptions that are made by this guide. Section 2 describes the CDPS platform configuration. Section 3 describes the platform preparation that is required to install the CDPS software. Section 4 describes the CPS software and its installation procedures. Section 5 describes the CDS software and its installation procedures. Section 6 describes various operation and maintenance procedures. Four appendices are also provided. Appendix A contains a list of used acronyms. Appendix B provides a terse description of common Ultrix commands that are used in administrative functions. Appendix C provides sample CPS and CDS configuration files. Appendix D provides a required list and a recommended list of Ultrix software subsets for installation on a CDPS platform.« less

  7. Comparative incidences of decompression illness in repetitive, staged, mixed-gas decompression diving: is 'dive fitness' an influencing factor?

    PubMed

    Sayer, Martin Dj; Akroyd, Jim; Williams, Guy D

    2008-06-01

    Wreck diving at Bikini Atoll consists of a relatively standard series of decompression dives with maximum depths in the region of 45-55 metres' sea water (msw). In a typical week of diving at Bikini, divers can perform up to 12 decompression dives to these depths over seven days; on five of those days, divers can perform two decompression dives per day. All the dives employ multi-level, staged decompression schedules using air and surface-supplied nitrox containing 80% oxygen. Bikini is serviced by a single diving operator and so a relatively precise record exists both of the actual number of dives undertaken and of the decompression illness incidents both for customer divers and the dive guides. The dive guides follow exactly the dive profiles and decompression schedules of the customers. Each dive guide will perform nearly 400 decompression dives a year, with maximum depths mostly around 50 msw, compared with an average of 10 (maximum of 12) undertaken typically by each customer diver in a week. The incidence of decompression illness for the customer population (presumed in the absence of medical records) is over ten times higher than that for the dive guides. The physiological reasons for such a marked difference are discussed in terms of customer demographics and dive-guide acclimatization to repetitive decompression stress. The rates of decompression illness for a range of diving populations are reviewed.

  8. Interventional magnetic resonance imaging-guided cell transplantation into the brain with radially branched deployment.

    PubMed

    Silvestrini, Matthew T; Yin, Dali; Martin, Alastair J; Coppes, Valerie G; Mann, Preeti; Larson, Paul S; Starr, Philip A; Zeng, Xianmin; Gupta, Nalin; Panter, S S; Desai, Tejal A; Lim, Daniel A

    2015-01-01

    Intracerebral cell transplantation is being pursued as a treatment for many neurological diseases, and effective cell delivery is critical for clinical success. To facilitate intracerebral cell transplantation at the scale and complexity of the human brain, we developed a platform technology that enables radially branched deployment (RBD) of cells to multiple target locations at variable radial distances and depths along the initial brain penetration tract with real-time interventional magnetic resonance image (iMRI) guidance. iMRI-guided RBD functioned as an "add-on" to standard neurosurgical and imaging workflows, and procedures were performed in a commonly available clinical MRI scanner. Multiple deposits of super paramagnetic iron oxide beads were safely delivered to the striatum of live swine, and distribution to the entire putamen was achieved via a single cannula insertion in human cadaveric heads. Human embryonic stem cell-derived dopaminergic neurons were biocompatible with the iMRI-guided RBD platform and successfully delivered with iMRI guidance into the swine striatum. Thus, iMRI-guided RBD overcomes some of the technical limitations inherent to the use of straight cannulas and standard stereotactic targeting. This platform technology could have a major impact on the clinical translation of a wide range of cell therapeutics for the treatment of many neurological diseases.

  9. A Descriptive Case Study of the Implementation of the Departmentalized Looping Team Model

    ERIC Educational Resources Information Center

    Miller, Cody R.

    2011-01-01

    The conceptual framework guiding this study focuses on local, state, and federal standards as well as demands on schools to improve performance of underserved student populations as impetuses for school structure changes. As related to the aforementioned framework, many schools have developed innovative school restructuring methods such as the…

  10. Observations Guide

    DTIC Science & Technology

    2015-11-01

    T) Organizational Performance (B) Sexual Harassment (C) Sex Harassment Retaliation (D) Discrimination - Sex (E) Discrimination - Race (F...standards?  Workplace and living conditions/environment. Look for graffiti, personal display of pictures, posters, artifacts, and general impressions...your briefing.  Determine the commander’s preferred style for an out-brief upon completion (ex. PowerPoint, executive summary).  Identify who else

  11. Fundamentals of Concrete and Cement Masonry. Instructional Materials.

    ERIC Educational Resources Information Center

    Hendrix, Laborn J.

    This curriculum guide provides materials for a course of instruction designed for training concrete masons who will make their careers in construction. It contains 4 sections and 18 instructional units in a standard format. Eight basic components that form a unit of instruction are performance objectives, suggested activities for the teacher,…

  12. Heating, Air-Conditioning, and Refrigeration Technician. National Skill Standards.

    ERIC Educational Resources Information Center

    Vocational Technical Education Consortium of States, Decatur, GA.

    This guide contains information on the knowledge and skills identified by industry as essential to the job performance of heating, air-conditioning, and refrigeration technicians. It is intended to assist training providers in public and private institutions, as well as in industry, to develop and implement training that will provide workers with…

  13. Provisional Teachers Failing the Mississippi Teacher Assessment Instruments for Certification: An Evaluation for 1991-92.

    ERIC Educational Resources Information Center

    Amos, Neil; Cheeseman, Robert H.

    The Mississippi Teacher Assessment Instruments (MTAIs) contain 16 teaching competencies (14 competencies measured by 3 separate instruments of the MTAI, and 2 performance standards assessed by the local district). The Teaching Plans and Materials MTAI guides assessment of beginning teachers' competence in planning instruction, selecting…

  14. A Systematic Guide for Planning or Improving Your Family Oriented Home-Based Program.

    ERIC Educational Resources Information Center

    Heffron, Mary Claire; Jonnson, Jerry C.

    Guidelines based on Project Head Start performance standards are offered for persons interested in starting and operating a home-based child development program providing individualized family services through home visits. Opening sections of the manual sensitize prospective service providers to problems and positive outcomes of home-based…

  15. Safety and You on the Job.

    ERIC Educational Resources Information Center

    West Virginia State Vocational Curriculum Lab., Cedar Lakes.

    Designed to assist instructors to be consistent with the Fair Labor Standards Act, which requires schools to provide safety instruction to students involved in any type of work experience or on-the-job training program, this curriculum guide presents a program to prepare students to perform their job function in a safe and healthy fashion. There…

  16. Planting Yellow-Poplar--Where We Stand Today

    Treesearch

    T.E. Russell

    1977-01-01

    Yellow-poplar can be established on a wide variety of sites with bare-rooted seedlings and standard planting techniques. Many past plantings have performed poorly because substandard seedlings have been planted on unsuitable sites and competing vegetation has not been adequately controlled. Research over the past two decades, however, provides workable guides for site...

  17. School-Based Management and Accountability Procedures Manual

    ERIC Educational Resources Information Center

    North Carolina Department of Public Instruction, 2004

    2004-01-01

    From the mission, several principles were developed to guide the School-Based Management and Accountability Program (the ABCs). (1) The ABCs sets standards for student performance and growth in the basics that are the foundation for further learning and achievement; (2) The accountability system in the ABCs plan is designed to result in improved…

  18. Home Economics Education Career Path Guide and Model Curriculum Standards.

    ERIC Educational Resources Information Center

    California State Univ., Northridge.

    This curriculum guide developed in California and organized in 10 chapters, provides a home economics education career path guide and model curriculum standards for high school home economics programs. The first chapter contains information on the following: home economics education in California, home economics careers for the future, home…

  19. A comparison of individualized treatment guided by VeriStrat with standard of care treatment strategies in patients receiving second-line treatment for advanced non-small cell lung cancer: A cost-utility analysis.

    PubMed

    Nelson, Richard E; Stenehjem, David; Akerley, Wallace

    2013-12-01

    Two therapies are appropriate as 2nd-line treatment of non-small cell lung cancer (NSCLC) patients: chemotherapy and epidermal growth factor receptor (EGFR) inhibitor therapy. VeriStrat, a serum proteomic test, can be used to guide treatment decisions for NSCLC patients. The test classifies patients as likely to benefit from either of these two treatment options. The objective of this research was to model the anticipated survival and cost-effectiveness of four different treatment strategies: chemotherapy for all patients (C-all), EGFR inhibitor for all (E-all), a performance status guided selection strategy (PS-guided), and a strategy guided by VeriStrat test results (V-guided). We developed a Markov model with the perspective of the U.S. health care system. Model inputs were taken from published literature for the base-case analysis. One-way and probabilistic sensitivity analyses were performed. The C-all treatment strategy showed the best overall survival outcome (10.1 months), followed by V-guided (9.6 months), PS-guided (9.2 months), and E-all (8.2 months) strategies. The incremental cost-effectiveness ratio (ICER) of a V-guided treatment strategy was $91,111 (vs. E-all) and $8462 (vs. PS-guided) per quality-adjusted life year (QALY). The ICER for C-all compared to V-guided was $105,616. This cost-utility analysis indicates that a treatment strategy guided by the VeriStrat test in patients receiving second-line therapy for NSCLC may experience an overall survival benefit at an incremental cost-effectiveness ratio that is reasonable when compared with other practices, including cancer treatments, generally covered in the U.S. health care system. However, treating all patients with chemotherapy yielded the greatest expected survival. Copyright © 2013. Published by Elsevier Ireland Ltd.

  20. Combined ultrasound-guided cutting-needle biopsy and standard pleural biopsy for diagnosis of malignant pleural effusions.

    PubMed

    Wang, Jinlin; Zhou, Xinghua; Xie, Xiaohong; Tang, Qing; Shen, Panxiao; Zeng, Yunxiang

    2016-11-17

    The most efficient approach to diagnose malignant pleural effusions (MPEs) is still controversial and uncertain. This study aimed to evaluate the utility of a combined approach using ultrasound (US)-guided cutting-needle biopsy (CNB) and standard pleural biopsy (SPB) for diagnosing MPE. Pleural effusions were collected from 172 patients for biochemical and microbiological analyses. US-guided CNB and SPB were performed in the same operation sequentially to obtain specimens for histological analysis. US-guided CNB and SPB procedures provided adequate material for histological analysis in 90.7 and 93.0% of cases, respectively, while a combination of the 2 techniques was in 96.5% of cases. The sensitivity, specificity, positive-predictive value (PPV), negative-predictive value (NPV) and diagnostic accuracy of US-guided CNB versus SPB were: 51.2 vs 63.4%, 100 vs 100%, 100 vs 100%, 64.9 vs 72.2% and 74.4 vs 81.3%, respectively. When CNB was combined with SPB, the corresponding values were 88.6, 100, 100, 88.6 and 93.9%, respectively. Whereas sensitivity, NPV and diagnostic accuracy were not significantly different between CNB and SPB, the combination of CNB and SPB significantly improved the sensitivity, NPV and diagnostic accuracy versus each technique alone (p < 0.05). Significant pain (eight patients), moderate haemoptysis (two patients) and chest wall haematomas (two patients) were observed following CNB, while syncope (four patients) and a slight pneumothorax (four patients) were observed following SPB. Use of a combination of US-guided CNB and SPB afforded a high sensitivity to diagnose MPEs, it is a convenient and safe approach.

  1. For a Child, Life is a Creative Adventure: Supporting Development and Learning through Art, Music, Movement, and Dialogue. A Guide for Parents and Professionals. = Para los ninos, la vida es una aventura creativa: Como estimular el desarrollo y el aprendizaje por medio de las artes visuales, la musica, el movimiento y el dialogo. Guia para padres de familia y profesionales.

    ERIC Educational Resources Information Center

    Cohen, Elena

    Recognizing that creativity facilitates children's learning and development, the Head Start Program Performance Standards require Head Start programs to include opportunities for creative self-expression. This guide with accompanying videotape, both in English- and Spanish- language versions, encourages and assists adults to support children's…

  2. A novel protocol for dispatcher assisted CPR improves CPR quality and motivation among rescuers-A randomized controlled simulation study.

    PubMed

    Rasmussen, Stinne Eika; Nebsbjerg, Mette Amalie; Krogh, Lise Qvirin; Bjørnshave, Katrine; Krogh, Kristian; Povlsen, Jonas Agerlund; Riddervold, Ingunn Skogstad; Grøfte, Thorbjørn; Kirkegaard, Hans; Løfgren, Bo

    2017-01-01

    Emergency dispatchers use protocols to instruct bystanders in cardiopulmonary resuscitation (CPR). Studies changing one element in the dispatcher's protocol report improved CPR quality. Whether several changes interact is unknown and the effect of combining multiple changes previously reported to improve CPR quality into one protocol remains to be investigated. We hypothesize that a novel dispatch protocol, combining multiple beneficial elements improves CPR quality compared with a standard protocol. A novel dispatch protocol was designed including wording on chest compressions, using a metronome, regular encouragements and a 10-s rest each minute. In a simulated cardiac arrest scenario, laypersons were randomized to perform single-rescuer CPR guided with the novel or the standard protocol. a composite endpoint of time to first compression, hand position, compression depth and rate and hands-off time (maximum score: 22 points). Afterwards participants answered a questionnaire evaluating the dispatcher assistance. The novel protocol (n=61) improved CPR quality score compared with the standard protocol (n=64) (mean (SD): 18.6 (1.4)) points vs. 17.5 (1.7) points, p<0.001. The novel protocol resulted in deeper chest compressions (mean (SD): 58 (12)mm vs. 52 (13)mm, p=0.02) and improved rate of correct hand position (61% vs. 36%, p=0.01) compared with the standard protocol. In both protocols hands-off time was short. The novel protocol improved motivation among rescuers compared with the standard protocol (p=0.002). Participants guided with a standard dispatch protocol performed high quality CPR. A novel bundle of care protocol improved CPR quality score and motivation among rescuers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. Study on convection improvement of standard vacuum tube

    NASA Astrophysics Data System (ADS)

    He, J. H.; Du, W. P.; Qi, R. R.; He, J. X.

    2017-11-01

    For the standard all-glass vacuum tube collector, enhancing the vacuum tube axial natural convection can improve its thermal efficiency. According to the study of the standard all-glass vacuum tube, three kinds of guide plates which can inhibit the radial convection and increase axial natural convection are designed, and theory model is established. Experiments were carried out on vacuum tubes with three types of baffles and standard vacuum tubes without the improvement. The results show that T-type guide plate is better than that of Y-type guide plate on restraining convection and increasing axial radial convection effect, Y type is better than that of flat plate type, all guide plates are better than no change; the thermal efficiency of the tube was 2.6% higher than that of the unmodified standard vacuum tube. The efficiency of the system in the experiment can be increased by 3.1%.

  4. NAGC Pre-K-Grade 12 Gifted Education Programming Standards: A Guide to Planning and Implementing High-Quality Services

    ERIC Educational Resources Information Center

    Johnsen, Susan K., Ed.

    2012-01-01

    The new Pre-K-Grade 12 Gifted Education Programming Standards should be part of every school district's repertoire of standards to ensure that the learning needs of advanced students are being met. "NAGC Pre-K-Grade 12 Gifted Education Programming Standards: A Guide to Planning and Implementing High-Quality Services" details six standards that…

  5. A Guide for Using Illinois Standards for Quality Agriculture Programs in Community Colleges.

    ERIC Educational Resources Information Center

    Illinois Univ., Urbana. Dept. of Vocational and Technical Education.

    As a result of a project to prepare standards for agricultural occupations programs in Illinois community colleges, this guide was developed to assist local community college instructors, administrators, and other local persons in the evaluation of local agricultural occupations programs. The first section of the guide explains (how standards…

  6. Randomized comparison of power Doppler ultrasonography-guided core-needle biopsy with open surgical biopsy for the characterization of lymphadenopathies in patients with suspected lymphoma.

    PubMed

    Pugliese, Novella; Di Perna, M; Cozzolino, I; Ciancia, G; Pettinato, G; Zeppa, P; Varone, V; Masone, S; Cerchione, C; Della Pepa, R; Simeone, L; Giordano, C; Martinelli, V; Salvatore, C; Pane, F; Picardi, M

    2017-04-01

    The sensitivity of lymph node core-needle biopsy under imaging guidance requires validation. We employed power Doppler ultrasonography (PDUS) to select the lymph node most suspected of malignancy and to histologically characterize it through the use of large cutting needle. Institutional review board approval and informed consent were obtained for this randomized clinical trial. In a single center between 1 January 2009 and 31 December 2015, patients with lymph node enlargement suspected for lymphoma were randomly assigned (1:1) to biopsy with either standard surgery or PDUS-guided 16-gauge modified Menghini needle. The primary endpoint was the superiority of sensitivity for the diagnosis of malignancy for core-needle cutting biopsy (CNCB). Secondary endpoints were times to biopsy, complications, and costs. A total of 376 patients were randomized into the two arms and received allocated biopsy. However, four patients undergoing CNCB were excluded for inadequate samples; thus, 372 patients were analyzed. Sensitivity for the detection of malignancy was significantly better for PDUS-guided CNCB [98.8%; 95% confidence interval (CI), 95.9-99.9] than standard biopsy (88.7%; 95% CI, 82.9-93; P < 0.001). For all secondary endpoints, the comparison was significantly disadvantageous for conventional approach. In particular, estimated cost per biopsy performed with standard surgery was 24-fold higher compared with that performed with CNCB. The presence of satellite enlarged reactive and/or necrotic lymph nodes may impair the success of an open surgical biopsy (OSB). PDUS and CNCB with adequate gauge are diagnostic tools that enable effective, safe, fast, and low-cost routine biopsy for patients with suspected lymphoma, avoiding psychological and physical pain of an unnecessary surgical intervention.

  7. Echogenic Catheters and Embryo Transfer Standardization.

    PubMed

    Urbina, Maria Teresa; Benjamin, Isaac; Medina, Randolfo; Lerner, Jorge

    2015-05-01

    1.To describe the standardization process and protocols of the ET method at our center. 2.To compare the performance of non-echogenic catheters with echogenic catheters during ultrasound-guided ET. Retrospective analysis of 2630 ET performed at UNIFERTES during 1997-2014, to describe standardization process and to compare the percentage of difficult ET between echogenic and non-echogenic catheters. We tested 17 non-echogenic and three echogenic catheters. Many variables were associated with the ease of ET: informed patients, waiting time for the procedure, speculum use, clinical touch, uterine contractions, cervical mucus removal, presence of blood before or after the procedure, full bladder, ultrasound guidance, uterocervical angle, mock transfer, catheter type (soft or hard, echogenic or non-echogenic, with stylet or not), catheter loading technique, duration of embryo loading (time interval since the embryos were removed from the incubator for loading until the catheter is passed to the physician), transfer procedure (time interval from the catheter was handed to the physician until the embryos were discharged in the uterus), catheter tip placement, retained embryos, bed rest after ET, operator´s proficiency. The diversity of catheters used and the percentage of difficult transfers decrease as the use of echogenic catheters increases. This process is necessary to minimize variation, ensure high quality, safe and evidence-based practice, and improve outcomes. To standardize the ET method allowed a quicker and easier transfer. The use of echogenic catheters simplified ET procedures guided by abdominal ultrasound.

  8. Implant image quality in dental radiographs recorded using a customized imaging guide or a standard film holder.

    PubMed

    Schropp, Lars; Stavropoulos, Andreas; Spin-Neto, Rubens; Wenzel, Ann

    2012-01-01

    To compare a customized imaging guide and a standard film holder for obtaining optimally projected intraoral radiographs of dental implants. Intraoral radiographs of four screw-type implants with different inclination placed in an upper or lower dental phantom model were recorded by 32 groups of examiners after a short instruction in the use of the RB-RB/LB-LB mnemonic rule. Half of the examiners recorded the images using a standard film holder and the other half used a customized imaging guide. Each radiograph was assessed under blinded conditions with regard to rendering of the implant threads and was assigned to one of four quality categories: (1) perfect, (2) not perfect, but clinically acceptable, (3) not acceptable, and (4) hopeless. For the upper jaw, the same number of exposures per implant were made to achieve an acceptable image (P=0.86) by the standard film holder method (median=2) and the imaging guide method (median=2). For the lower jaw, medians for the imaging guide method and the film holder method were 1 and 2, respectively (P=0.004). For the imaging guide method, the first exposure was rated as perfect/acceptable in 62% of the cases and for the film holder method in 41% of the cases (P=0.013). After ≤ 2 exposures, 78% (imaging guide method) and 69% (film holder method) of the implant images were perfect/acceptable (P=0.23). The implant inclination did not have a major influence on the outcomes. Perfect or acceptable images were achieved after two exposures with the same frequency either using a customized imaging guide method or a standard film holder method. However, the use of a customized imaging guide method was overall significantly superior to a standard film holder method in terms of obtaining perfect or acceptable images with only one exposure. © 2011 John Wiley & Sons A/S.

  9. Cost-effectiveness of renin-guided treatment of hypertension.

    PubMed

    Smith, Steven M; Campbell, Jonathan D

    2013-11-01

    A plasma renin activity (PRA)-guided strategy is more effective than standard care in treating hypertension (HTN). However, its clinical implementation has been slow, presumably due in part to economic concerns. We estimated the cost effectiveness of a PRA-guided treatment strategy compared with standard care in a treated but uncontrolled HTN population. We estimated costs, quality-adjusted life years (QALYs), and the incremental cost-effectiveness ratio (ICER) of PRA-guided therapy compared to standard care using a state-transition simulation model with alternate patient characteristic scenarios and sensitivity analyses. Patient-specific inputs for the base case scenario, males average age 63 years, reflected best available data from a recent clinical trial of PRA-guided therapy. Transition probabilities were estimated using Framingham risk equations or derived from the literature; costs and utilities were derived from the literature. In the base case scenario for males, the lifetime discounted costs and QALYs were $23,648 and 12.727 for PRA-guided therapy and $22,077 and 12.618 for standard care, respectively. The base case ICER was $14,497/QALY gained. In alternative scenario analyses varying patient input parameters, the results were sensitive to age, gender, baseline systolic blood pressure, and the addition of cardiovascular risk factors. Univariate sensitivity analyses demonstrated that results were most sensitive to varying the treatment effect of PRA-guided therapy and the cost of the PRA test. Our results suggest that PRA-guided therapy compared with standard care increases QALYs and medical costs in most scenarios. PRA-guided therapy appears to be most cost effective in younger persons and those with more cardiovascular risk factors. © American Journal of Hypertension, Ltd 2013. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. 75 FR 38026 - Medicare Program; Identification of Backward Compatible Version of Adopted Standard for E...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-01

    ... Programs (NCPDP) Prescriber/ Pharmacist Interface SCRIPT standard, Implementation Guide, Version 10... Prescriber/Pharmacist Interface SCRIPT standard, Version 8, Release 1 and its equivalent NCPDP Prescriber/Pharmacist Interface SCRIPT Implementation Guide, Version 8, Release 1 (hereinafter referred to as the...

  11. Comparisons of ANS, ASME, AWS, and NFPA standards cited in the NRC standard review plan, NUREG-0800, and related documents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ankrum, A.R.; Bohlander, K.L.; Gilbert, E.R.

    This report provides the results of comparisons of the cited and latest versions of ANS, ASME, AWS and NFPA standards cited in the NRC Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants (NUREG 0800) and related documents. The comparisons were performed by Battelle Pacific Northwest Laboratories in support of the NRC`s Standard Review Plan Update and Development Program. Significant changes to the standards, from the cited version to the latest version, are described and discussed in a tabular format for each standard. Recommendations for updating each citation in the Standard Review Plan are presented.more » Technical considerations and suggested changes are included for related regulatory documents (i.e., Regulatory Guides and the Code of Federal Regulations) citing the standard. The results and recommendations presented in this document have not been subjected to NRC staff review.« less

  12. The estimation of the measurement results with using statistical methods

    NASA Astrophysics Data System (ADS)

    Velychko, O.; Gordiyenko, T.

    2015-02-01

    The row of international standards and guides describe various statistical methods that apply for a management, control and improvement of processes with the purpose of realization of analysis of the technical measurement results. The analysis of international standards and guides on statistical methods estimation of the measurement results recommendations for those applications in laboratories is described. For realization of analysis of standards and guides the cause-and-effect Ishikawa diagrams concerting to application of statistical methods for estimation of the measurement results are constructed.

  13. Ultrasound-guided thoracenthesis: the V-point as a site for optimal drainage positioning.

    PubMed

    Zanforlin, A; Gavelli, G; Oboldi, D; Galletti, S

    2013-01-01

    In the latest years the use of lung ultrasound is increasing in the evaluation of pleural effusions, because it makes follow-up easier and drainage more efficient by providing guidance on the most appropriate sampling site. However, no standardized approach for ultrasound-guided thoracenthesis is actually available. To evaluate our usual ultrasonographic landmark as a possible standard site to perform thoracenthesis by assessing its value in terms of safety and efficiency (success at first attempt, drainage as complete as possible). Hospitalized patients with non organized pleural effusion underwent thoracenthesis after ultrasound evaluation. The point showing on ultrasound the maximum thickness of the effusion ("V-point") was chosen for drainage. 45 ultrasound guided thoracenthesis were performed in 12 months. In 22 cases there were no complications; 16 cases of cough, 2 cases of mild dyspnea without desaturation, 4 cases of mild pain; 2 cases of complications requiring medical intervention occurred. No case of pneumothorax related to the procedure was detected. In all cases drainage was successful on the first attempt. The collected values of maximum thickness at V-point (min 3.4 cm - max 15.3 cm) and drained fluid volume (min 70 ml - max 2000 ml) showed a significative correlation (p < 0.0001). When the thickness was greater or equal to 9.9 cm, drained volume was always more than 1000 ml. The measure of the maximum thickness at V-point provides high efficiency to ultrasound guided thoracentesis and allows to estimate the amount of fluid in the pleural cavity. It is also an easy parameter that makes the proposed method quick to learn and apply.  

  14. Ultrasonography in Acupuncture-Uses in Education and Research.

    PubMed

    Leow, Mabel Qi He; Cui, Shu Li; Mohamed Shah, Mohammad Taufik Bin; Cao, Taige; Tay, Shian Chao; Tay, Peter Kay Chai; Ooi, Chin Chin

    2017-06-01

    This study aims to explore the potential use of ultrasound in locating the second posterior sacral foramen acupuncture point, quantifying depth of insertion and describing surrounding anatomical structures. We performed acupuncture needle insertion on a study team member. There were four steps in our experiment. First, the acupuncturist located the acupuncture point by palpation. Second, we used an ultrasound machine to visualize the structures surrounding the location of the acupuncture point and measure the depth required for needle insertion. Third, the acupuncturist inserted the acupuncture needle into the acupuncture point at an angle of 30°. Fourth, we performed another ultrasound scan to ensure that the needle was in the desired location. Results suggested that ultrasound could be used to locate the acupuncture point and estimate the depth of needle insertion. The needle was inserted to a depth of 4.0 cm to reach the surface of the sacral foramen. Based on Pythagoras theorem, taking a needle insertion angle of 30° and a needle insertion depth of 4.0 cm, the estimated perpendicular depth is 1.8 cm. An ultrasound scan corroborated the depth of 1.85 cm. The use of an ultrasound-guided technique for needle insertion in acupuncture practice could help standardize the treatment. Clinicians and students would be able to visualize and measure the depth of the sacral foramen acupuncture point, to guide the depth of needle insertion. This methodological guide could also be used to create a standard treatment protocol for research. A similar mathematical guide could also be created for other acupuncture points in future. Copyright © 2017. Published by Elsevier B.V.

  15. How Good Is Our School? Ensuring Effective Transitions. Self-Evaluation Series

    ERIC Educational Resources Information Center

    Her Majesty's Inspectorate of Education, 2006

    2006-01-01

    This is one of a series of guides to self-evaluation building on the advice given in the publications "How good is our school?" and "The Child at the Centre." It also shows how the relevant National Care Standards can be applied alongside performance indicators and quality indicators to evaluate the effectiveness of…

  16. Microspoiler Actuation for Guided Projectiles

    DTIC Science & Technology

    2016-01-06

    and be hardened to gun -launch. Several alternative designs will be explored using various actuation techniques, and downselection to an optimal design...aerodynamic optimization of the microspoiler mechanism, mechanical design/ gun hardening, and parameter estimation from experimental data. These...performed using the aerodynamic parameters in Table 2. Projectile trajectories were simulated without gravity at zero gun elevation. The standard 30mm

  17. A Manual of Simplified Laboratory Methods for Operators of Wastewater Treatment Facilities.

    ERIC Educational Resources Information Center

    Westerhold, Arnold F., Ed.; Bennett, Ernest C., Ed.

    This manual is designed to provide the small wastewater treatment plant operator, as well as the new or inexperienced operator, with simplified methods for laboratory analysis of water and wastewater. It is emphasized that this manual is not a replacement for standard methods but a guide for plants with insufficient equipment to perform analyses…

  18. Guiding Biliteracy Development: Appropriating Cross-Linguistic and Conceptual Knowledge to Sustain Second-Language Reading Comprehension

    ERIC Educational Resources Information Center

    Soto Huerta, Mary Esther

    2012-01-01

    To examine the second-language reading development of 45 fourth-grade Latino bilinguals, a sequential mixed methods study was conducted in two phases (Creswell, 2009). The quantitative data collected in the first phase generated an index of the group's reading performance based on two grade-level assessments, a state-mandated standardized reading…

  19. Invention and Innovation: A Standards-Based Middle School Model Course Guide. Advancing Technological Literacy: ITEA Professional Series

    ERIC Educational Resources Information Center

    International Technology Education Association (ITEA), 2005

    2005-01-01

    This guide presents a model for a standards-based contemporary technology education course for the middle school. This model course guide features an exploratory curriculum thrust for a cornerstone middle level course. It provides teachers with an overview of the concept, suggestions for planning the course, and ideas for developing…

  20. North Carolina Public Schools Facility Standards. A Guide for Planning School Facilities.

    ERIC Educational Resources Information Center

    Knott, Gerald H.; Lora, James M.; Acker, Marjorie L.; Taynton, Steven; Logan, Gladys B.; Harrell, Ronald C.

    The State of North Carolina has developed a planning guide for those in the process of building, enlarging, or renovating school facilities. This guide defines and describes the educational spaces needed to support a modern, comprehensive educational program and sets minimal standards for the types and sizes of spaces required. It serves as a…

  1. Guide to International Academic Standards for Athletics Eligibility for Students Entering Fall 2007

    ERIC Educational Resources Information Center

    Mills, Lisa; Nguyen, Binh; Auten, Lisa

    2007-01-01

    The "NCAA Guide to International Academic Standards for Athletics Eligibility" provides specific criteria to be used as a guide in reviewing the initial eligibility (graduation, core curriculum, grade-point average and ACT/SAT test scores) of students who have completed any portion of their secondary education in a non-United States…

  2. Standards Based Reform. Abbott Implementation Resource Guide

    ERIC Educational Resources Information Center

    Passantino, Claire; Kenyon, Susan

    2004-01-01

    The goal of this guide is to provide information, support and practical tools that may help educators design, implement, and evaluate their school's standards-based education program. In order to work, a comprehensive, standards-based educational program must, by definition, be the organizing structure upon which the school program operates.…

  3. Handy Reference Guide to the Fair Labor Standards Act.

    ERIC Educational Resources Information Center

    Employment Standards Administration (DOL), Washington, DC. Wage and Hour Div.

    This guide provides general information about the application of the Fair Labor Standards Act (FLSA), as amended. Topics covered are basic wage standards, employees covered, tipped employees, employer-furnished facilities, subminimum wage provisions, equal pay provisions, exemptions, child labor provisions, recordkeeping, terms used in the FLSA,…

  4. Virtual fixtures as tools to enhance operator performance in telepresence environments

    NASA Astrophysics Data System (ADS)

    Rosenberg, Louis B.

    1993-12-01

    This paper introduces the notion of virtual fixtures for use in telepresence systems and presents an empirical study which demonstrates that such virtual fixtures can greatly enhance operator performance within remote environments. Just as tools and fixtures in the real world can enhance human performance by guiding manual operations, providing localizing references, and reducing the mental processing required to perform a task, virtual fixtures are computer generated percepts overlaid on top of the reflection of a remote workspace which can provide similar benefits. Like a ruler guiding a pencil in a real manipulation task, a virtual fixture overlaid on top of a remote workspace can act to reduce the mental processing required to perform a task, limit the workload of certain sensory modalities, and most of all allow precision and performance to exceed natural human abilities. Because such perceptual overlays are virtual constructions they can be diverse in modality, abstract in form, and custom tailored to individual task or user needs. This study investigates the potential of virtual fixtures by implementing simple combinations of haptic and auditory sensations as perceptual overlays during a standardized telemanipulation task.

  5. Iliac screw fixation using computer-assisted computer tomographic image guidance: technical note.

    PubMed

    Shin, John H; Hoh, Daniel J; Kalfas, Iain H

    2012-03-01

    Iliac screw fixation is a powerful tool used by spine surgeons to achieve fusion across the lumbosacral junction for a number of indications, including deformity, tumor, and pseudarthrosis. Complications associated with screw placement are related to blind trajectory selection and excessive soft tissue dissection. To describe the technique of iliac screw fixation using computed tomographic (CT)-based image guidance. Intraoperative registration and verification of anatomic landmarks are performed with the use of a preoperatively acquired CT of the lumbosacral spine. With the navigation probe, the ideal starting point for screw placement is selected while visualizing the intended trajectory and target on a computer screen. Once the starting point is selected and marked with a burr, a drill guide is docked within this point and the navigation probe re-inserted, confirming the trajectory. The probe is then removed and the high-speed drill reinserted within the drill guide. Drilling is performed to a depth measured on the computer screen and a screw is placed. Confirmation of accurate placement of iliac screws can be performed with standard radiographs. CT-guided navigation allows for 3-dimensional visualization of the pelvis and minimizes complications associated with soft-tissue dissection and breach of the ilium during screw placement.

  6. Accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints.

    PubMed

    Siegenthaler, Andreas; Mlekusch, Sabine; Trelle, Sven; Schliessbach, Juerg; Curatolo, Michele; Eichenberger, Urs

    2012-08-01

    Cervical zygapophysial joint nerve blocks typically are performed with fluoroscopic needle guidance. Descriptions of ultrasound-guided block of these nerves are available, but only one small study compared ultrasound with fluoroscopy, and only for the third occipital nerve. To evaluate the potential usefulness of ultrasound-guidance in clinical practice, studies that determine the accuracy of this technique using a validated control are essential. The aim of this study was to determine the accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints using fluoroscopy as control. Sixty volunteers were studied. Ultrasound-imaging was used to place the needle to the bony target of cervical zygapophysial joint nerve blocks. The levels of needle placement were determined randomly (three levels per volunteer). After ultrasound-guided needle placement and application of 0.2 ml contrast dye, fluoroscopic imaging was performed for later evaluation by a blinded pain physician and considered as gold standard. Raw agreement, chance-corrected agreement κ, and chance-independent agreement Φ between the ultrasound-guided placement and the assessment using fluoroscopy were calculated to quantify accuracy. One hundred eighty needles were placed in 60 volunteers. Raw agreement was 87% (95% CI 81-91%), κ was 0.74 (0.64-0.83), and Φ 0.99 (0.99-0.99). Accuracy varied significantly between the different cervical nerves: it was low for the C7 medial branch, whereas all other levels showed very good accuracy. Ultrasound-imaging is an accurate technique for performing cervical zygapophysial joint nerve blocks in volunteers, except for the medial branch blocks of C7.

  7. Maywood interim storage site. Annual site environmental report, calendar year 1985

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1986-05-01

    During 1985, the environmental monitoring program was continued at the Maywood Interim Storage Site (MISS), a US Department of Energy (DOE) facility located in the Borough of Maywood and the Township of Rochelle Park, New Jersey. The MISS is presently used for the storage of low-level radioactively contaminated soils. Monitoring results show that the MISS is in compliance with DOE concentration guides and radiation protection standards. Derived Concentration Guides (DCGs) represent the concentrations of radionuclides in air or water that would limit the radiation dose to 100 mrem/yr. The applicable guides have been revised since the 1984 environmental monitoring reportmore » was published. The guides applied in 1984 were based on a radiation protection standard of 500 mrem/yr; the guides applied for 1985 are based on a standard of 100 mrem/yr.« less

  8. Research of performance prediction to energy on hydraulic turbine

    NASA Astrophysics Data System (ADS)

    Quan, H.; Li, R. N.; Li, Q. F.; Han, W.; Su, Q. M.

    2012-11-01

    Refer to the low specific speed Francis turbine blade design principle and double-suction pump structure. Then, design a horizontal double-channel hydraulic turbine Francis. Through adding different guide vane airfoil and and no guide vane airfoil on the hydraulic conductivity components to predict hydraulic turbine energy and using Fluent software to numerical simulation that the operating conditions and point. The results show that the blade pressure surface and suction surface pressure is low when the hydraulic turbine installation is added standard positive curvature of the guide vane and modified positive curvature of guide vane. Therefore, the efficiency of energy recovery is low. However, the pressure of negative curvature guide vane and symmetric guide vane added on hydraulic turbine installations is larger than that of the former ones, and it is conducive to working of runner. With the decreasing of guide vane opening, increasing of inlet angle, flow state gets significantly worse. Then, others obvious phenomena are that the reflux and horizontal flow appeared in blade pressure surface. At the same time, the vortex was formed in Leaf Road, leading to the loss of energy. Through analyzing the distribution of pressure, velocity, flow lines of over-current flow in the the back hydraulic conductivity components in above programs we can known that the hydraulic turbine installation added guide vane is more reasonable than without guide vanes, it is conducive to improve efficiency of energy conversion.

  9. Development and Evaluation of a Novel Curved Biopsy Device for CT-Guided Biopsy of Lesions Unreachable Using Standard Straight Needle Trajectories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schulze-Hagen, Maximilian Franz, E-mail: mschulze@ukaachen.de; Pfeffer, Jochen; Zimmermann, Markus

    PurposeTo evaluate the feasibility of a novel curved CT-guided biopsy needle prototype with shape memory to access otherwise not accessible biopsy targets.Methods and MaterialsA biopsy needle curved by 90° with specific radius was designed. It was manufactured using nitinol to acquire shape memory, encased in a straight guiding trocar to be driven out for access of otherwise inaccessible targets. Fifty CT-guided punctures were conducted in a biopsy phantom and 10 CT-guided punctures in a swine corpse. Biposies from porcine liver and muscle tissue were separately gained using the biopsy device, and histological examination was performed subsequently.ResultsMean time for placement ofmore » the trocar and deployment of the inner biopsy needle was ~205 ± 69 and ~93 ± 58 s, respectively, with a mean of ~4.5 ± 1.3 steps to reach adequate biopsy position. Mean distance from the tip of the needle to the target was ~0.7 ± 0.8 mm. CT-guided punctures in the swine corpse took relatively longer and required more biopsy steps (~574 ± 107 and ~380 ± 148 s, 8 ± 2.6 steps). Histology demonstrated appropriate tissue samples in nine out of ten cases (90%).ConclusionsTargets that were otherwise inaccessible via standard straight needle trajectories could be successfully reached with the curved biopsy needle prototype. Shape memory and preformed size with specific radius of the curved needle simplify the target accessibility with a low risk of injuring adjacent structures.« less

  10. A Guide for Developing Standard Operating Job Procedures for the Screening & Grinding Process Wastewater Treatment Facility. SOJP No. 1.

    ERIC Educational Resources Information Center

    Deal, Gerald A.; Montgomery, James A.

    This guide describes standard operating job procedures for the screening and grinding process of wastewater treatment facilities. The objective of this process is the removal of coarse materials from the raw waste stream for the protection of subsequent equipment and processes. The guide gives step-by-step instructions for safety inspection,…

  11. A Guide for Developing Standard Operating Job Procedures for the Sludge Thickening Process Wastewater Treatment Facility. SOJP No. 9.

    ERIC Educational Resources Information Center

    Schwing, Carl M.

    This guide describes standard operating job procedures for the screening and grinding process of wastewater treatment facilities. The objective of this process is the removal of coarse materials from the raw waste stream for the protection of subsequent equipment and processes. The guide gives step-by-step instructions for safety inspection,…

  12. A Guide for Developing Standard Operating Job Procedures for the Digestion Process Wastewater Treatment Facility. SOJP No. 10.

    ERIC Educational Resources Information Center

    Schwing, Carl M.

    This guide describes standard operating job procedures for the digestion process of wastewater treatment facilities. This process is for reducing the volume of sludge to be treated in subsequent units and to reduce the volatile content of sludge. The guide gives step-by-step instructions for pre-startup, startup, continuous operating, shutdown,…

  13. A Guide for Developing Standard Operating Job Procedures for the Tertiary Multimedia Filtration Process Wastewater Treatment Facility. SOJP No. 7.

    ERIC Educational Resources Information Center

    Petrasek, Al, Jr.

    This guide describes the standard operating job procedures for the tertiary multimedia filtration process of wastewater treatment plants. The major objective of the filtration process is the removal of suspended solids from the reclaimed wastewater. The guide gives step-by-step instructions for pre-start up, start-up, continuous operation, and…

  14. Compliance with the guide for commissioning oral surgery: an audit and discussion.

    PubMed

    Modgill, O; Shah, A

    2017-10-13

    Introduction The Guide for commissioning oral surgery and oral medicine published by NHS England (2015) prescribes the level of complexity of oral surgery and oral medicine investigations and procedures to be carried out within NHS services. These are categorised as Level 1, Level 2, Level 3A and Level 3B. An audit was designed to ascertain the level of oral surgery procedures performed by clinicians of varying experience and qualification working in a large oral surgery department within a major teaching hospital.Materials and methods Two audit cycles were conducted on retrospective case notes and radiographic review of 100 patient records undergoing dental extractions within the Department of Oral Surgery at King's College Dental Hospital. The set gold standard was: '100% of Level 1 procedures should be performed by dental undergraduates or discharged back to the referring general dental practitioner'. Data were collected and analysed on a Microsoft Excel spreadsheet. The results of the first audit cycle were presented to all clinicians within the department in a formal meeting, recommendations were made and an action plan implemented prior to undertaking a second cycle.Results The first cycle revealed that 25% of Level 1 procedures met the set gold standard, with Level 2 practitioners performing the majority of Level 1 and Level 2 procedures. The second cycle showed a marked improvement, with 66% of Level 1 procedures meeting the set gold standard.Conclusion Our audit demonstrates that whilst we were able to achieve an improvement with the set gold standard, several barriers still remain to ensure that patients are treated by the appropriate level of clinician in a secondary care setting. We have used this audit as a foundation upon which to discuss the challenges faced in implementation of the commissioning framework within both primary and secondary dental care and strategies to overcome these challenges, which are likely to be encountered in any NHS care setting in which oral surgery procedures are performed.

  15. Interdisciplinary consensus on the uses and technique of MR-guided vacuum-assisted breast biopsy (VAB): results of a European consensus meeting.

    PubMed

    Heywang-Köbrunner, Sylvia H; Sinnatamby, Ruchi; Lebeau, Annette; Lebrecht, Antje; Britton, Peter D; Schreer, Ingrid

    2009-11-01

    Quality assurance of MR-guided vacuum-assisted breast biopsy (VAB). A consensus was achieved based on the existing literature and experience of an interdisciplinary group comprising European specialists in breast imaging and VAB. Full imaging work-up must be completed according to existing standards before an indication for MR-guided VAB is established. The procedure should be reserved for lesions demonstrable by MRI alone. Acquisition of >24 cores (11-Gauge) should be routinely attempted, with the intention of sufficiently removing small lesions for accurate diagnosis. Following biopsy the patient should be re-imaged to demonstrate the biopsy site and its proximity to the lesion and hence the likely accuracy of the sampling. All patients should be discussed in a regular interdisciplinary conference and a documented consensus reached regarding patient management. Regular audit and review of all MR-guided VAB results and subsequent follow-up are recommended. This consensus includes protocols for the indication, performance parameters, interdisciplinary interpretation therapeutic recommendation, documentation and follow-up of MR-guided VAB. It does not replace official recommendations for percutaneous biopsy.

  16. Feasibility of real-time magnetic resonance-guided angioplasty and stenting of renal arteries in vitro and in Swine, using a new polyetheretherketone-based magnetic resonance-compatible guidewire.

    PubMed

    Kos, Sebastian; Huegli, Rolf; Hofmann, Eugen; Quick, Harald H; Kuehl, Hilmar; Aker, Stephanie; Kaiser, Gernot M; Borm, Paul J; Jacob, Augustinus L; Bilecen, Deniz

    2009-04-01

    Demonstrate the usability of a new polyetheretherketone (PEEK)-based MR-compatible guidewire for renal artery catheterization, angioplasty, and stenting under MR-guidance using MR-visible markers, in vitro and in vivo. The new 0.035'' guidewire with fiber-reinforced PEEK core, a soft tip, and a hydrophilic coating was used. Paramagnetic markings were coated on the wire and nonbraided catheters for passive visualization. Bending stiffness of the guidewire was compared with available hydrophilic guidewires (Terumo Glidewire Stiff and Standard). A human aortic silicon phantom and 2 pigs were used. The study was animal care and use approved by the committee. Under MR-guidance, renal arteries were catheterized, balloon angioplasty was performed, and balloon expandable renal artery stents were deployed in vivo. Post mortem autopsy was performed. Guidewire visibility, pushability, steerability, and device-support capabilities of the marked guidewire were qualitatively assessed. Procedure times were recorded. Bending stiffness of the new PEEK-based wire was comparable with Standard Glidewire. In vitro and in vivo guidewire guidance, catheter configuration, renal artery catheterization, and balloon angioplasty were successful. In pigs, stent deployments were successful in both renal arteries. Autopsy revealed acceptable stent positioning. Guidewire visibility through applied markers was acceptable. Steerability, pushability, and device support were good in vitro and in vivo. The PEEK-based guide allows percutaneous MR-guided renal artery angioplasty and stenting with sufficient visibility, good steerability, pushability, and device support.

  17. Emergency medical technician-basic : national standard curriculum (instructor's course guide)

    DOT National Transportation Integrated Search

    1994-01-01

    The curriculum, Emergency Medical Technician-Basic: National Standard Curriculum, : is the cornerstone of EMS prehospital training. Presented here is the : instructor's guide. This new curriculum parallels the recommendations of the : National EMS Ed...

  18. Rapid construction of insulated genetic circuits via synthetic sequence-guided isothermal assembly

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Torella, JP; Boehm, CR; Lienert, F

    2013-12-28

    In vitro recombination methods have enabled one-step construction of large DNA sequences from multiple parts. Although synthetic biological circuits can in principle be assembled in the same fashion, they typically contain repeated sequence elements such as standard promoters and terminators that interfere with homologous recombination. Here we use a computational approach to design synthetic, biologically inactive unique nucleotide sequences (UNSes) that facilitate accurate ordered assembly. Importantly, our designed UNSes make it possible to assemble parts with repeated terminator and insulator sequences, and thereby create insulated functional genetic circuits in bacteria and mammalian cells. Using UNS-guided assembly to construct repeating promoter-gene-terminatormore » parts, we systematically varied gene expression to optimize production of a deoxychromoviridans biosynthetic pathway in Escherichia coli. We then used this system to construct complex eukaryotic AND-logic gates for genomic integration into embryonic stem cells. Construction was performed by using a standardized series of UNS-bearing BioBrick-compatible vectors, which enable modular assembly and facilitate reuse of individual parts. UNS-guided isothermal assembly is broadly applicable to the construction and optimization of genetic circuits and particularly those requiring tight insulation, such as complex biosynthetic pathways, sensors, counters and logic gates.« less

  19. What Are the Principles That Guide Behaviors in the Operating Room?: Creating a Framework to Define and Measure Performance.

    PubMed

    Madani, Amin; Vassiliou, Melina C; Watanabe, Yusuke; Al-Halabi, Becher; Al-Rowais, Mohammed S; Deckelbaum, Dan L; Fried, Gerald M; Feldman, Liane S

    2017-02-01

    To identify the core principles that guide expert intraoperative behaviors and to use these principles to develop a universal framework that defines intraoperative performance. Surgical outcomes are associated with intraoperative cognitive skills. Yet, our understanding of factors that control intraoperative judgment and decision-making are limited. As a result, current methods for training and measuring performance are somewhat subjective-more task rather than procedure-oriented-and usually not standardized. They thus provide minimal insight into complex cognitive processes that are fundamental to patient safety. Cognitive task analyses for 6 diverse surgical procedures were performed using semistructured interviews and field observations to describe the thoughts, behaviors, and actions that characterize and guide expert performance. Verbal data were transcribed, supplemented with content from published literature, coded, thematically analyzed using grounded-theory by 4 independent reviewers, and synthesized into a list of items. A conceptual framework was developed based on 42 semistructured interviews lasting 45 to 120 minutes, 5 expert panels and 51 field observations involving 35 experts, and 135 sources from the literature. Five domains of intraoperative performance were identified: psychomotor skills, declarative knowledge, advanced cognitive skills, interpersonal skills, and personal resourcefulness. Within the advanced cognitive skills domain, 21 themes were perceived to guide the behaviors of surgeons: 18 for surgical planning and error prevention, and 3 for error/injury recognition, rescue, and recovery. The application of these thought patterns was highly case-specific and variable amongst subspecialties, environments, and individuals. This study provides a comprehensive definition of intraoperative expertise, with greater insight into the complex cognitive processes that seem to underlie optimal performance. This framework provides trainees and other nonexperts with the necessary information to use in deliberate practice and the creation of effective thought habits that characterize expert performance. It may help to identify gaps in performance, and to isolate root causes of surgical errors with the ultimate goal of improving patient safety.

  20. Visually guided tube thoracostomy insertion comparison to standard of care in a large animal model.

    PubMed

    Hernandez, Matthew C; Vogelsang, David; Anderson, Jeff R; Thiels, Cornelius A; Beilman, Gregory; Zielinski, Martin D; Aho, Johnathon M

    2017-04-01

    Tube thoracostomy (TT) is a lifesaving procedure for a variety of thoracic pathologies. The most commonly utilized method for placement involves open dissection and blind insertion. Image guided placement is commonly utilized but is limited by an inability to see distal placement location. Unfortunately, TT is not without complications. We aim to demonstrate the feasibility of a disposable device to allow for visually directed TT placement compared to the standard of care in a large animal model. Three swine were sequentially orotracheally intubated and anesthetized. TT was conducted utilizing a novel visualization device, tube thoracostomy visual trocar (TTVT) and standard of care (open technique). Position of the TT in the chest cavity were recorded using direct thoracoscopic inspection and radiographic imaging with the operator blinded to results. Complications were evaluated using a validated complication grading system. Standard descriptive statistical analyses were performed. Thirty TT were placed, 15 using TTVT technique, 15 using standard of care open technique. All of the TT placed using TTVT were without complication and in optimal position. Conversely, 27% of TT placed using standard of care open technique resulted in complications. Necropsy revealed no injury to intrathoracic organs. Visual directed TT placement using TTVT is feasible and non-inferior to the standard of care in a large animal model. This improvement in instrumentation has the potential to greatly improve the safety of TT. Further study in humans is required. Therapeutic Level II. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Performance testing of the environmental TLD system for the Three Mile Island Nuclear Station.

    PubMed

    Toke, L F; Carson, B H; Baker, G G; McBride, M H; Plato, P A; Miklos, J A

    1984-05-01

    Panasonic UD-801 thermoluminescent dosimeters ( TLDs ) containing two calcium sulfate phosphors were tested under Performance Specification 3.1 established by the American National Standard Institute ( ANSI75 ) and in the U.S. Nuclear Regulatory Commission's Regulatory Guide 4.13 ( NRC77 ). The specific qualifying tests included TLD uniformity, reproducibility, energy dependence and directional dependence. The overall measurement uncertainties and associated confidence levels are within the prescribed guidelines defined in the qualifying requirements for environmental TLDs .

  2. Introducing a feedback training system for guided home rehabilitation.

    PubMed

    Kohler, Fabian; Schmitz-Rode, Thomas; Disselhorst-Klug, Catherine

    2010-01-15

    As the number of people requiring orthopaedic intervention is growing, individualized physiotherapeutic rehabilitation and adequate postoperative care becomes increasingly relevant. The chances of improvement in the patients condition is directly related to the performance and consistency of the physiotherapeutic exercises.In this paper a smart, cost-effective and easy to use Feedback Training System for home rehabilitation based on standard resistive elements is introduced. This ensures high accuracy of the exercises performed and offers guidance and control to the patient by offering direct feedback about the performance of the movements.46 patients were recruited and performed standard physiotherapeutic training to evaluate the system. The results show a significant increase in the patient's ability to reproduce even simple physiotherapeutic exercises when being supported by the Feedback Training System. Thus physiotherapeutic training can be extended into the home environment whilst ensuring a high quality of training.

  3. Pilot study: EatFit impacts sixth graders' academic performance on achievement of mathematics and english education standards.

    PubMed

    Shilts, Mical Kay; Lamp, Cathi; Horowitz, Marcel; Townsend, Marilyn S

    2009-01-01

    Investigate the impact of a nutrition education program on student academic performance as measured by achievement of education standards. Quasi-experimental crossover-controlled study. California Central Valley suburban elementary school (58% qualified for free or reduced-priced lunch). All sixth-grade students (n = 84) in the elementary school clustered in 3 classrooms. 9-lesson intervention with an emphasis on guided goal setting and driven by the Social Cognitive Theory. Multiple-choice survey assessing 5 education standards for sixth-grade mathematics and English at 3 time points: baseline (T1), 5 weeks (T2), and 10 weeks (T3). Repeated measures, paired t test, and analysis of covariance. Changes in total scores were statistically different (P < .05), with treatment scores (T3 - T2) generating more gains. The change scores for 1 English (P < .01) and 2 mathematics standards (P < .05; P < .001) were statistically greater for the treatment period (T3 - T2) compared to the control period (T2 - T1). Using standardized tests, results of this pilot study suggest that EatFit can improve academic performance measured by achievement of specific mathematics and English education standards. Nutrition educators can show school administrators and wellness committee members that this program can positively impact academic performance, concomitant to its primary objective of promoting healthful eating and physical activity.

  4. A reliable technique for ultrasound-guided perineural injection in ulnar neuropathy at the elbow.

    PubMed

    Hamscha, Ulrike M; Tinhofer, Ines; Heber, Stefan; Grisold, Wolfgang; Weninger, Wolfgang J; Meng, Stefan

    2017-08-01

    Ulnar neuropathy at the elbow (UNE) is a common peripheral compression neuropathy and, in most cases, occurs at 2 sites, the retroepicondylar groove or the cubital tunnel. With regard to a potential therapeutic approach with perineural corticosteroid injection, the aim of this study was to evaluate the distribution of injection fluid applied at a standard site. We performed ultrasound-guided (US-guided) perineural injections to the ulnar nerve halfway between the olecranon and the medial epicondyle in 21 upper limbs from 11 non-embalmed cadavers. In anatomic dissection we investigated the spread of injected ink. Ink was successfully injected into the perineural sheath of the ulnar nerve in all 21 cases (cubital tunnel: 21 of 21; retroepicondylar groove: 19 of 21). US-guided injection between the olecranon and the medial epicondyle is a feasible and safe method to reach the most common sites of ulnar nerve entrapment. Muscle Nerve 56: 237-241, 2017. © 2016 Wiley Periodicals, Inc.

  5. An assessment of thromboelastometry to monitor blood coagulation and guide transfusion support in liver transplantation.

    PubMed

    Blasi, Annabel; Beltran, Joan; Pereira, Arturo; Martinez-Palli, Graciela; Torrents, Abiguei; Balust, Jaume; Zavala, Elizabeth; Taura, Pilar; Garcia-Valdecasas, Juan-Carlos

    2012-09-01

    Rotation thromboelastometry (TEM) has been proposed as a convenient alternative to standard coagulation tests in guiding the treatment of coagulopathy during orthotopic liver transplantation (OLT). This study was aimed at assessing the value of TEM in monitoring blood coagulation and guide transfusion support in OLT. Standard coagulation and TEM (EXTEM and FIBTEM) tests were performed at four preestablished intraoperative time points in 236 OLTs and prospectively recorded in a dedicated database together with the main operative and transfusion data. Transfusion thresholds were based on standard coagulation tests. Spearman's rank correlation (ρ), linear regression, and receiver operating characteristic curves were used when appropriate. EXTEM maximum clot firmness (MCF(EXTEM)) was the TEM variable that best correlated with the platelet (PLT) and fibrinogen levels (ρ = 0.62 and ρ = 0.69, respectively). MCF(FIBTEM) correlated with fibrinogen level (ρ = 0.70). EXTEM clot amplitude at 10 minutes (A10(EXTEM)) was a good linear predictor of MCF(EXTEM) (R(2) =0.93). The cutoff values that best predicted the transfusion threshold for PLTs and fibrinogen were A10(EXTEM) = 35 mm and A10(FIBTEM) = 8 mm. At these values, the negative and positive predictive accuracies of TEM to predict the transfusion thresholds were 95 and 27%, respectively. A10(EXTEM) is an adequate TEM variable to guide therapeutic decisions during OLT. Patients with A10(EXTEM) of greater than 35 mm are unlikely to bleed because of coagulation deficiencies, but using A10(EXTEM) of not more than 35 mm as the sole transfusion criterion can lead to unnecessary utilization of PLTs and fibrinogen-rich products. © 2012 American Association of Blood Banks.

  6. Image use in field guides and identification keys: review and recommendations.

    PubMed

    Leggett, Roxanne; Kirchoff, Bruce K

    2011-01-01

    Although illustrations have played an important role in identification keys and guides since the 18th century, their use has varied widely. Some keys lack all illustrations, while others are heavily illustrated. Even within illustrated guides, the way in which images are used varies considerably. Here, we review image use in paper and electronic guides, and establish a set of best practices for image use in illustrated keys and guides. Our review covers image use in both paper and electronic guides, though we only briefly cover apps for mobile devices. With this one exception, we cover the full range of guides, from those that consist only of species descriptions with no keys, to lavishly illustrated technical keys. Emphasis is placed on how images are used, not on the operation of the guides and key, which has been reviewed by others. We only deal with operation when it impacts image use. Few illustrated keys or guides use images in optimal ways. Most include too few images to show taxonomic variation or variation in characters and character states. The use of multiple images allows easier taxon identification and facilitates the understanding of characters. Most images are usually not standardized, making comparison between images difficult. Although some electronic guides allow images to be enlarged, many do not. The best keys and guides use standardized images, displayed at sizes that are easy to see and arranged in a standardized manner so that similar images can be compared across species. Illustrated keys and glossaries should contain multiple images for each character state so that the user can judge variation in the state. Photographic backgrounds should not distract from the subject and, where possible, should be of a standard colour. When used, drawings should be prepared by professional botanical illustrators, and clearly labelled. Electronic keys and guides should allow images to be enlarged so that their details can be seen.

  7. Image use in field guides and identification keys: review and recommendations

    PubMed Central

    Leggett, Roxanne; Kirchoff, Bruce K.

    2011-01-01

    Background and aims Although illustrations have played an important role in identification keys and guides since the 18th century, their use has varied widely. Some keys lack all illustrations, while others are heavily illustrated. Even within illustrated guides, the way in which images are used varies considerably. Here, we review image use in paper and electronic guides, and establish a set of best practices for image use in illustrated keys and guides. Scope Our review covers image use in both paper and electronic guides, though we only briefly cover apps for mobile devices. With this one exception, we cover the full range of guides, from those that consist only of species descriptions with no keys, to lavishly illustrated technical keys. Emphasis is placed on how images are used, not on the operation of the guides and key, which has been reviewed by others. We only deal with operation when it impacts image use. Main points Few illustrated keys or guides use images in optimal ways. Most include too few images to show taxonomic variation or variation in characters and character states. The use of multiple images allows easier taxon identification and facilitates the understanding of characters. Most images are usually not standardized, making comparison between images difficult. Although some electronic guides allow images to be enlarged, many do not. Conclusions The best keys and guides use standardized images, displayed at sizes that are easy to see and arranged in a standardized manner so that similar images can be compared across species. Illustrated keys and glossaries should contain multiple images for each character state so that the user can judge variation in the state. Photographic backgrounds should not distract from the subject and, where possible, should be of a standard colour. When used, drawings should be prepared by professional botanical illustrators, and clearly labelled. Electronic keys and guides should allow images to be enlarged so that their details can be seen. PMID:22476475

  8. High-Altitude Electromagnetic Pulse (HEMP) Testing

    DTIC Science & Technology

    2011-11-10

    Security Classification Guide ( SCG ). b. The HEMP simulation facility shall have a measured map of the peak amplitude waveform of the...Quadripartite Standardization Agreement s, sec second SCG security classification guide SN serial number SOP Standard Operating Procedure

  9. Standard guide for developing a cost-effective risk mitigation plan for new and existing constructed facilities

    Treesearch

    Jeffrey Prestemon

    2011-01-01

    Protecting constructed facilities from damages from natural and man-made hazards in a costeffective manner is a challenging task. Several measures of economic performance are available for evaluating building-related investments. These measures include, but are not limited to, life-cycle cost, present value net savings, savings-to-investment ratio, and adjusted...

  10. Guiding Principles for Stabilization and Reconstruction

    DTIC Science & Technology

    2009-01-01

    of justice that conform with interna- tional human rights standards, and a system exists to ensure equal and effective application of the law...legisla- tive performance.434 A strong committee system that enhances lawmaking, oversight, and representation is a typical feature in effective ...transparency, and effectiveness when developing a bank- ing system . In the early stages, focus on creating a relevant, transparent, and effective

  11. Performance of HESCO Bastion Units Under Combined Normal and Cyclic Lateral Loading

    DTIC Science & Technology

    2017-02-01

    technology was not designed for residential applications, engineering standards would be needed to guide the designers of soldier contingency housing. In...public release; distribution is unlimited. The U.S. Army Engineer Research and Development Center (ERDC) solves the nation’s toughest... engineering and environmental challenges. ERDC develops innovative solutions in civil and military engineering , geospatial sciences, water resources, and

  12. Development of a Contact Permeation Test Fixture and Method

    DTIC Science & Technology

    2013-04-01

    direct contact with the skin, indicates the need for a quantitative contact test method. Comparison tests were conducted with VX on a standardized...Guide for the Care and Use of Laboratory Animals (8th ed.; National Research Council: Washington, DC, 2011). This test was also performed in...1 1.2 Development of a Contact-Based Permeation Test Method ........................................ 1 2. EXPERIMENTAL PROCEDURES

  13. Computational study: The influence of omni-directional guide vane on the flow pattern characteristic around Savonius wind turbine

    NASA Astrophysics Data System (ADS)

    Wicaksono, Yoga Arob; Tjahjana, D. D. D. P.

    2017-01-01

    Standart Savonius wind turbine have a low performance such as low coefficient of power and low coefficient of torque compared with another type of wind turbine. This phenomenon occurs because the wind stream can cause the negative pressure at the returning rotor. To solve this problem, standard Savonius combined with Omni Directional Guide Vane (ODGV) proposed. The aim of this research is to study the influence of ODGV on the flow pattern characteristic around of Savonius wind turbine. The numerical model is based on the Navier-Stokes equations with the standard k-ɛ turbulent model. This equation solved by a finite volume discretization method. This case was analyzed by commercial computational fluid dynamics solver such as SolidWorks Flow Simulations. Simulations were performed at the different wind directions; there are 0°, 30°,60° at 4 m/s wind speed. The numerical method validated with the past experimental data. The result indicated that the ODGV able to augment air flow to advancing rotor and decrease the negative pressure in the upstream of returning rotor compared to the bare Savonius wind turbine.

  14. A Guide for Developing Standard Operating Job Procedures for the Sludge Conditioning & Dewatering Process Wastewater Treatment Facility. SOJP No. 11.

    ERIC Educational Resources Information Center

    Schwing, Carl M.

    This guide describes standard operating job procedures for the sludge conditioning and dewatering process of wastewater treatment facilities. In this process, sludge is treated with chemicals to make the sludge coagulate and give up its water more easily. The treated sludge is then dewatered using a vacuum filter. The guide gives step-by-step…

  15. Consistent evaluation of an ultrasound-guided surgical navigation system by utilizing an active validation platform

    NASA Astrophysics Data System (ADS)

    Kim, Younsu; Kim, Sungmin; Boctor, Emad M.

    2017-03-01

    An ultrasound image-guided needle tracking systems have been widely used due to their cost-effectiveness and nonionizing radiation properties. Various surgical navigation systems have been developed by utilizing state-of-the-art sensor technologies. However, ultrasound transmission beam thickness causes unfair initial evaluation conditions due to inconsistent placement of the target with respect to the ultrasound probe. This inconsistency also brings high uncertainty and results in large standard deviations for each measurement when we compare accuracy with and without the guidance. To resolve this problem, we designed a complete evaluation platform by utilizing our mid-plane detection and time of flight measurement systems. The evaluating system uses a PZT element target and an ultrasound transmitting needle. In this paper, we evaluated an optical tracker-based surgical ultrasound-guided navigation system whereby the optical tracker tracks marker frames attached on the ultrasound probe and the needle. We performed ten needle trials of guidance experiment with a mid-plane adjustment algorithm and with a B-mode segmentation method. With the midplane adjustment, the result showed a mean error of 1.62+/-0.72mm. The mean error increased to 3.58+/-2.07mm without the mid-plane adjustment. Our evaluation system can reduce the effect of the beam-thickness problem, and measure ultrasound image-guided technologies consistently with a minimal standard deviation. Using our novel evaluation system, ultrasound image-guided technologies can be compared under equal initial conditions. Therefore, the error can be evaluated more accurately, and the system provides better analysis on the error sources such as ultrasound beam thickness.

  16. Deriving allowable properties of lumber : a practical guide for interpretation of ASTM standards

    Treesearch

    Alan Bendtsen; William L. Galligan

    1978-01-01

    The ASTM standards for establishing clear wood mechanical properties and for deriving structural grades and related allowable properties for visually graded lumber can be confusing and difficult for the uninitiated to interpret. This report provides a practical guide to using these standards for individuals not familiar with their application. Sample stress...

  17. Common Core Standards for High School Mathematics: A Quick-Start Guide

    ERIC Educational Resources Information Center

    Dempsey, Kathleen; Schwols, Armitra

    2012-01-01

    Shifting your high school's math program to new Common Core standards is much easier when teachers and leaders have this handy guide. Getting a copy for every staff member involved in the process ensures everyone knows: (1) How the six conceptual categories throughout the math standards are connected and reinforced; (2) How the modeling standards…

  18. Creating Better School-Age Care Jobs: Model Work Standards.

    ERIC Educational Resources Information Center

    Haack, Peggy

    Built on the premise that good school-age care jobs are the cornerstone of high-quality services for school-age youth and their families, this guide presents model work standards for school-age care providers. The guide begins with a description of the strengths and challenges of the school-age care profession. The model work standards are…

  19. A Guide to Child Labor Provisions of the Fair Labor Standards Act.

    ERIC Educational Resources Information Center

    Wage and Hour and Public Contracts Divisions (DOL), Washington, DC.

    This revised guide to the child labor provisions of the Fair Labor Standards Act contains general information useful to employers and coordinators of cooperative and work experience programs involving employment of youth under 18 years of age. Included in the document are provisions relating to: (1) age standards, (2) coverage of the act, (3)…

  20. National ITS Architecture and Standards Resource Guide

    DOT National Transportation Integrated Search

    1998-09-01

    The Transportation Equity Act for the 21st Century (TEA-21) encourages the use of the National ITS Architecture and the adoption of ITS standards and protocols. This guide provides field personnel with guidance and resources necessary for implementin...

  1. Agile Multi-Function Arrays

    DTIC Science & Technology

    2007-07-01

    been put into place to guide the standards process. 6. If the balloting results in 75% approval then the draft standard is sub- mitted to the IEEE-SA...as functionality and timeliness. Such a design process presumably guided the design for the AMRFC test bed. The multifunction apertures for...Integrated Topside should be guided by the same design process. Engaging in a spiral design process will lead to the most effective selection of research

  2. Teaching Standard English as a Second Dialect to Primary School Children in Hilo, Hawaii. Appendix B: Teacher's Guide and Lessons. Volume II of II Volumes. Final Report.

    ERIC Educational Resources Information Center

    Sugai, Elaine E.; Sugano, Miyoko

    This document comprises the teacher's guide and lessons for teaching standard English to kindergarten through third grade children in Hilo, Hawaii. Sections are (1) Teacher's Guide, (2) Audio-Visual Aids, (3) Phonemic Symbol List, (4) Phonology Lesson Section, and (5) Structure Lesson Section. Appended are a short glossary of terms,…

  3. Percutaneous Treatment of an Infected Aneurysmal Sac Secondary to Aortoesophageal Fistula with a History of Stent-Graft Treatment for Thoracic Aortic Aneurysm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Numan, Furuzan, E-mail: drfgulsen@yahoo.com; Gulsen, Fatih; Cantasdemir, Murat

    2012-06-15

    A 68-year-old man who was subjected to stent-grafting of a descending thoracic aortic aneurysm (TAA) 4 months previously was admitted to our hospital with constitutional symptoms, including high fever, sweating, nausea, vomiting, weight loss, and backache. An infected aneurysmal sac was suspected based on computed tomography (CT) findings, and an aortoesophageal fistula (AEF) was identified during esophagoscopy. CT-guided aspiration was performed using a 20-G Chiba needle, confirming the presence of infection. For treatment of the infected aneurysmal sac, CT-guided percutaneous catheter drainage in a prone position was performed under general anesthesia with left endobronchial intubation. Drainage catheter insertion was successfullymore » performed using the Seldinger technique, which is not a standard treatment of an infected aneurysmal sac. Improvement in the patient's clinical condition was observed at follow-ups, and CT showed total regression of the collection in the aneurysmal sac.« less

  4. Chemistry in Past and New Science Frameworks and Standards: Gains, Losses, and Missed Opportunities

    ERIC Educational Resources Information Center

    Talanquer, Vicente; Sevian, Hannah

    2014-01-01

    Science education frameworks and standards play a central role in the development of curricula and assessments, as well as in guiding teaching practices in grades K-12. Recently, the National Research Council published a new Framework for K-12 Science Education that has guided the development of the Next Generation Science Standards. In this…

  5. THE SCHOOL PLANT GUIDE FOR PLANNING SCHOOL PLANTS OF PENNSYLVANIA. ARCHITECTURAL DESIGN REQUIREMENTS AND GENERAL, ELECTRIC, HEATING AND VENTILATING, AND PLUMBING STANDARDS.

    ERIC Educational Resources Information Center

    Pennsylvania State Dept. of Public Instruction, Harrisburg.

    A GUIDE COVERING ARCHITECTURAL DESIGN REQUIREMENTS, ELECTRIC, HEATING AND VENTILATING, AND PLUMBING STANDARDS AS APPROVED BY THE STATE BOARD OF EDUCATION IN 1966. THE FOLLOWING MINIMUM STANDARD FOR NEW BUILDING, ALTERATIONS, AND ADDITIONS ARE OUTLINED--(1) SPATIAL ENVIRONMENTAL FACTORS, SUCH AS CEILING HEIGHTS, INTERIOR SANITARY FACILITIES, ROOMS…

  6. Using Learning Analytics to Enhance Student Learning in Online Courses Based on Quality Matters Standards

    ERIC Educational Resources Information Center

    Martin, Florence; Ndoye, Abdou; Wilkins, Patricia

    2016-01-01

    Quality Matters is recognized as a rigorous set of standards that guide the designer or instructor to design quality online courses. We explore how Quality Matters standards guide the identification and analysis of learning analytics data to monitor and improve online learning. Descriptive data were collected for frequency of use, time spent, and…

  7. Digital Imagery Compression Best Practices Guide - A Motion Imagery Standards Profile (MISP) Compliant Architecture

    DTIC Science & Technology

    2012-06-01

    MISP) COMPLIANT ARCHITECTURE WHITE SANDS MISSILE RANGE REAGAN TEST SITE YUMA PROVING GROUND DUGWAY PROVING GROUND ABERDEEN TEST CENTER...DIGITAL MOTION IMAGERY COMPRESSION BEST PRACTICES GUIDE – A MOTION IMAGERY STANDARDS PROFILE (MISP) COMPLIANT ARCHITECTURE ...delivery, and archival purposes. These practices are based on a Motion Imagery Standards Profile (MISP) compliant architecture , which has been defined

  8. Technical Review of Law Enforcement Standards and Guides Relative to Incident Management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stenner, Robert D.; Salter, R.; Stanton, J. R.

    2009-03-24

    In an effort to locate potential law enforcement-related standards that support incident management, a team from the Pacific Northwest National Laboratory (PNNL) contacted representatives from the National Institute of Standards-Office of Law Enforcement Standards (NIST-OLES), National Institute of Justice (NIJ), Federal Bureau of Investigation (FBI), Secret Service, ASTM International committees that have a law enforcement focus, and a variety of individuals from local and regional law enforcement organizations. Discussions were held with various state and local law enforcement organizations. The NIJ has published several specific equipment-related law enforcement standards that were included in the review, but it appears that lawmore » enforcement program and process-type standards are developed principally by organizations that operate at the state and local level. Input is provided from state regulations and codes and from external non-government organizations (NGOs) that provide national standards. The standards that are adopted from external organizations or developed independently by state authorities are available for use by local law enforcement agencies on a voluntary basis. The extent to which they are used depends on the respective jurisdictions involved. In some instances, use of state and local disseminated standards is mandatory, but in most cases, use is voluntary. Usually, the extent to which these standards are used appears to depend on whether or not jurisdictions receive certification from a “governing” entity due to their use and compliance with the standards. In some cases, these certification-based standards are used in principal but without certification or other compliance monitoring. In general, these standards appear to be routinely used for qualification, selection for employment, and training. In these standards, the term “Peace Officer” is frequently used to refer to law enforcement personnel. This technical review of national law enforcement standards and guides identified the following four guides as having content that supports incident management: • TE-02-02 Guide to Radio Communications Interoperability Strategies and Products • OSHA 335-10N Preparing and Protecting Security Personnel in Emergencies • NIJ 181584 Fire and Arson Scene Evidence: A Guide for Public Safety Personnel • NIJ 181869 A Guide for Explosion and Bombing Scene Investigation In conversations with various state and local law enforcement officials, it was determined that the following National Fire Protection Association (NPFA) standards are generally recognized and tend to be universally used by law enforcement organizations across the country: • NFPA 1600 Standard on Disaster/Emergency Management and Business Continuity Programs • NFPA 1561 Standard on Fire Department Incident Management Systems • NFPA 472 Standard for Competence of Responders to Hazardous Materials/Weapons of Mass Destruction Incidents (2008 Edition) • NFPA 473 Standard for Competencies for EMS Personnel Responding to Hazardous Materials/Weapons of Mass Destruction Incidents (2008 Edition)« less

  9. Imaging-Guided Core-Needle Breast Biopsy: Impact of Meditation and Music Interventions on Patient Anxiety, Pain, and Fatigue.

    PubMed

    Soo, Mary Scott; Jarosz, Jennifer A; Wren, Anava A; Soo, Adrianne E; Mowery, Yvonne M; Johnson, Karen S; Yoon, Sora C; Kim, Connie; Hwang, E Shelley; Keefe, Francis J; Shelby, Rebecca A

    2016-05-01

    To evaluate the impact of guided meditation and music interventions on patient anxiety, pain, and fatigue during imaging-guided breast biopsy. After giving informed consent, 121 women needing percutaneous imaging-guided breast biopsy were randomized into three groups: (1) guided meditation; (2) music; (3) standard-care control group. During biopsy, the meditation and music groups listened to an audio-recorded, guided, loving-kindness meditation and relaxing music, respectively; the standard-care control group received supportive dialogue from the biopsy team. Immediately before and after biopsy, participants completed questionnaires measuring anxiety (State-Trait Anxiety Inventory Scale), biopsy pain (Brief Pain Inventory), and fatigue (modified Functional Assessment of Chronic Illness Therapy-Fatigue). After biopsy, participants completed questionnaires assessing radiologist-patient communication (modified Questionnaire on the Quality of Physician-Patient Interaction), demographics, and medical history. The meditation and music groups reported significantly greater anxiety reduction (P values < .05) and reduced fatigue after biopsy than the standard-care control group; the standard-care control group reported increased fatigue after biopsy. The meditation group additionally showed significantly lower pain during biopsy, compared with the music group (P = .03). No significant difference in patient-perceived quality of radiologist-patient communication was noted among groups. Listening to guided meditation significantly lowered biopsy pain during imaging-guided breast biopsy; meditation and music reduced patient anxiety and fatigue without compromising radiologist-patient communication. These simple, inexpensive interventions could improve women's experiences during core-needle breast biopsy. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  10. Guidelines and Standards for Proprietary Schools.

    ERIC Educational Resources Information Center

    Georgia State Board of Education, Atlanta.

    This guide contains information pertaining to Georgia law, rules, regulations, and standards of practice for regulating proprietary schools in Georgia. Section 1 of the guide presents operation guidelines, including definitions, exemptions, general provisions, certificates of approval of schools, and appeals procedures. Section 2 presents minimum…

  11. A multicenter, primary-care-based, open-label study to assess the success of converting opioid-experienced patients with chronic moderate-to-severe pain to morphine sulfate and naltrexone hydrochloride extended-release capsules using a standardized conversion guide.

    PubMed

    Setnik, Beatrice; Roland, Carl L; Sommerville, Kenneth W; Pixton, Glenn C; Berke, Robert; Calkins, Anne; Goli, Veeraindar

    2015-01-01

    To evaluate the conversion of opioid-experienced patients with chronic moderate-to-severe pain to extended-release morphine sulfate with sequestered naltrexone hydrochloride (MSN) using a standardized conversion guide. This open-label, single-arm study was conducted in 157 primary care centers in the United States. A total of 684 opioid-experienced adults with chronic moderate-to-severe pain were converted to oral administration of MSN from transdermal fentanyl and oral formulations of hydrocodone, hydromorphone, methadone, oxycodone, oxymorphone, and other morphine products using a standardized conversion guide. The primary endpoint was the percentage of patients achieving a stable MSN dose within a 6-week titration phase. Secondary endpoints included duration of time to stable dose, number of titration steps, safety and efficacy measures, and investigator assessment of conversion guide utility. Of the 684 patients, 51.3% were converted to a stable dose of MSN (95% confidence interval: 47.5%, 55.1%). The mean (standard deviation) number of days to stable dose was 20 (8.94), and number of titration steps to stable dose was 2.4 (1.37). The majority of adverse events were mild/moderate and consistent with opioid therapy. Mean pain scores at stable dose decreased from baseline. Investigators were generally satisfied with the conversion guide and, in 94% of cases, reported they would use it again. Conversion to MSN treatment using the standardized MSN conversion guide was an attainable goal in approximately half of the population of opioid-experienced patients with chronic moderate-to-severe pain. Investigators found the guide to be a useful tool to assist conversion of opioid-experienced patients to MSN.

  12. The Simple View, Instructional Level, and the Plight of Struggling Fifth-/Sixth-Grade Readers

    ERIC Educational Resources Information Center

    Morris, Darrell; Meyer, Carla; Trathen, Woodrow; McGee, Jennifer; Vines, Nora; Stewart, Trevor; Gill, Tom; Schlagal, Robert

    2017-01-01

    This study explored print-processing and vocabulary differences among a group of 5th- and 6th-grade students who had scored below the 50th percentile on a standardized reading test. Guided by the simple view of reading, we applied cut scores (low/high) to the students' performance on print-processing and vocabulary tasks. The design allowed for…

  13. Midcourse Guidance Study for Tactical Guided Weapons. Volume I. Survey and Analysis

    DTIC Science & Technology

    1976-08-01

    relatively moderate when compared to air intercept guidance requirements.) The alignment phase involved the comparison of gyrocom- passing (using... phase of flight for discrete updates. The AFBGW aero and guidance configuration is derived from current Air Force glide weapon concepts. The AFBGW... comparable midcourse flight phase . Harpoon and Standard Arm represent performance levels similar to the AFBGW requirements, but differences in

  14. Design, durability and low cost processing technology for composite fan exit guide vanes

    NASA Technical Reports Server (NTRS)

    Blecherman, S. S.

    1979-01-01

    A lightweight composite fan exit guide vane for high bypass ratio gas turbine engine application was investigated. Eight candidate material/design combinations were evaluated by NASTRAN finite element analyses. A total of four combinations were selected for further analytical evaluation, part fabrication by two ventors, and fatigue test in dry and wet condition. A core and shell vane design was chosen in which the unidirectional graphite core fiber was the same for all candidates. The shell material, fiber orientation, and ply configuration were varied. Material tests were performed on raw material and composite specimens to establish specification requirements. Pre-test and post-test microstructural examination and nondestructive analyses were conducted to determine the effect of material variations on fatigue durability and failure mode. Relevant data were acquired with respect to design analysis, materials properties, inspection standards, improved durability, weight benefits, and part price of the composite fan exit guide vane.

  15. A selective laser sintering guide for transferring a virtual plan to real time surgery in composite mandibular reconstruction with free fibula osseous flaps.

    PubMed

    Leiggener, C; Messo, E; Thor, A; Zeilhofer, H-F; Hirsch, J-M

    2009-02-01

    The free fibular flap is the standard procedure for reconstructing mandibular defects. The graft has to be contoured to fit the defect so preoperative planning is required. The systems used previously do not allow transfer of the surgical plan to the operation room in an optimal way. The authors present a method to bring the virtual plan to real time surgery using a rapid prototyping guide. Planning was conducted using the Surgicase CMF software simulating surgery on a workstation. The osteotomies were translated into a rapid prototyping guide, sterilised and applied during surgery on the fibula allowing for the osteotomies and osteosynthesis to be performed with intact circulation. During reconstruction the authors were able to choose the best site for the osteotomies regarding circulation and as a result increased the precision and speed of treatment.

  16. Shade selection performed by novice dental professionals and colorimeter.

    PubMed

    Klemetti, E; Matela, A-M; Haag, P; Kononen, M

    2006-01-01

    The objective of this study was to test inter-observer variability in shade selection for porcelain restorations, using three different shade guides: Vita Lumin Vacuum, Vita 3D-Master and Procera. Nineteen young dental professionals acted as observers. The results were also compared with those of a digital colorimeter (Shade Eye Ex; Shofu, Japan). Regarding repeatability, no significant differences were found between the three shade guides, although repeatability was relatively low (33-43%). Agreement with the colorimetric results was also low (8-34%). In conclusion, shade selection shows moderate to great inter-observer variation. In teaching and standardizing the shade selection procedure, a digital colorimeter may be a useful educational tool.

  17. Parachute Rigger Knowledge Test Guide

    DOT National Transportation Integrated Search

    1995-01-01

    The Flight Standards Service of the Federal Aviation Administration (FAA) has developed this guide to help : applicants meet the knowledge requirements for parachute rigger certification. : This guide contains information about eligibility requiremen...

  18. Implementation of clinical decision support in young children with acute gastroenteritis: a randomized controlled trial at the emergency department.

    PubMed

    Geurts, Dorien; de Vos-Kerkhof, Evelien; Polinder, Suzanne; Steyerberg, Ewout; van der Lei, Johan; Moll, Henriëtte; Oostenbrink, Rianne

    2017-02-01

    Acute gastroenteritis (AGE) is one of the most frequent reasons for young children to visit emergency departments (EDs). We aimed to evaluate (1) feasibility of a nurse-guided clinical decision support system for rehydration treatment in children with AGE and (2) the impact on diagnostics, treatment, and costs compared with usual care by attending physician. A randomized controlled trial was performed in 222 children, aged 1 month to 5 years at the ED of the Erasmus MC-Sophia Children's hospital in The Netherlands ( 2010-2012). Outcome included (1) feasibility, measured by compliance of the nurses, and (2) length of stay (LOS) at the ED, the number of diagnostic tests, treatment, follow-up, and costs. Due to failure of post-ED weight measurement, we could not evaluate weight difference as measure for dehydration. Patient characteristics were comparable between the intervention (N = 113) and the usual care group (N = 109). Implementation of the clinical decision support system proved a high compliance rate. The standardized use of oral ORS (oral rehydration solution) significantly increased from 52 to 65%(RR2.2, 95%CI 1.09-4.31 p < 0.05). We observed no differences in other outcome measures. Implementation of nurse-guided clinical decision support system on rehydration treatment in children with AGE showed high compliance and increase standardized use of ORS, without differences in other outcome measures. What is Known: • Acute gastroenteritis is one of the most frequently encountered problems in pediatric emergency departments. • Guidelines advocate standardized oral treatment in children with mild to moderate dehydration, but appear to be applied infrequently in clinical practice. What is New: • Implementation of a nurse-guided clinical decision support system on treatment of AGE in young children showed good feasibility, resulting in a more standardized ORS use in children with mild to moderate dehydration, compared to usual care. • Given the challenges to perform research in emergency care setting, the ED should be experienced and adequately equipped, especially during peak times.

  19. Mortality and Outcome Comparison Between Brain Tissue Oxygen Combined with Intracranial Pressure/Cerebral Perfusion Pressure-Guided Therapy and Intracranial Pressure/Cerebral Perfusion Pressure-Guided Therapy in Traumatic Brain Injury: A Meta-Analysis.

    PubMed

    Xie, Qiang; Wu, Hai-Bing; Yan, Yu-Feng; Liu, Meng; Wang, Er-Song

    2017-04-01

    The combination of brain tissue oxygen and standard intracranial pressure (ICP)/cerebral perfusion pressure (CPP)-guided therapy is thought to improve traumatic brain injury (TBI) prognosis compared with standard ICP/CPP-guided therapy. However, related results of previous observational studies and recently published cohort studies and randomized controlled trials (RCTs) remain controversial. The objective of this study was to compare the effect of the combined therapy with that of standard ICP/CPP-guided therapy on mortality rate, favorable outcome, ICP/CPP, and length of stay (LOS). We systematically searched PubMed, Embase, Cochrane Library, ClinicalTrials.gov, and Web of Science in July 2016 for studies comparing the combined therapy and standard ICP/CPP-guided therapy. Random-effect and fixed-effect models were used for pooled analyses. After screening 362 studies, 8 cohort studies and 1 RCT were included. Primary outcomes were mortality and favorable outcome. The overall mortality risk ratio showed no obvious advantages between the 2 groups (risk ratio [RR], 0.76; 95% confidence interval [CI], 0.54-1.06) and discharge mortality (RR, 1.01; 95% CI, 0.80-1.26) and 3-month mortality (RR, 0.77; 95% CI, 0.53-1.12). Compared with the ICP/CPP group, the combined group was more likely to achieve better outcome during the 6 months after TBI (RR, 1.26; 95% CI, 1.04-1.52) or exactly at 6 months (RR, 1.34; 95% CI, 1.07-1.68), whereas ICP (standardized mean difference [SMD], -0.19; 95% CI, -0.43 to 0.05), CPP (SMD, 0.13; 95% CI, -0.09 to 0.35), and LOS (SMD, 0.13; 95% CI, -0.11 to 0.37) showed no obvious differences. Compared with standard ICP/CPP-guided therapy, brain tissue oxygen combined with ICP/CPP-guided therapy improved long-term outcomes without any effects on mortality, ICP/CPP, or LOS. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Guide to Permitting Hydrogen Motor Fuel Dispensing Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rivkin, Carl; Buttner, William; Burgess, Robert

    2016-03-28

    The purpose of this guide is to assist project developers, permitting officials, code enforcement officials, and other parties involved in developing permit applications and approving the implementation of hydrogen motor fuel dispensing facilities. The guide facilitates the identification of the elements to be addressed in the permitting of a project as it progresses through the approval process; the specific requirements associated with those elements; and the applicable (or potentially applicable) codes and standards by which to determine whether the specific requirements have been met. The guide attempts to identify all applicable codes and standards relevant to the permitting requirements.

  1. Higher Education Finance Manual: Volume 1. Data Providers' Guide.

    ERIC Educational Resources Information Center

    Collier, Douglas J.; Allen, Richard H.

    This data providers' guide, the first volume of the revised "Higher Education Finance Manual," comprehensively describes national financial reporting standards, including those prescribed for the Higher Education General Information Survey (HEGIS) reports, and includes the information needed to comply with those standards. General…

  2. National Skill Standards Implementation Guide.

    ERIC Educational Resources Information Center

    National Vocational Technical Education Foundation, Washington, DC.

    This guide was developed to encourage state policy makers and local school boards to implement the national skill standards formulated by the National Institute for Automotive Service Excellence (ASE) and the National Automotive Technician Education Foundation (NATEF) in high schools, technical schools, and technical and community colleges.…

  3. PET Probe-Guided Surgery in Patients with Breast Cancer: Proposal for a Methodological Approach.

    PubMed

    Orsaria, Paolo; Chiaravalloti, Agostino; Fiorentini, Alessandro; Pistolese, Chiara; Vanni, Gianluca; Granai, Alessandra Vittoria; Varvaras, Dimitrios; Danieli, Roberta; Schillaci, Orazio; Petrella, Giuseppe; Buonomo, Oreste Claudio

    2017-01-02

    Although it is valuable for detecting distant metastases, identifying recurrence, and evaluating responses to chemotherapy, the role of 18 F-fluorodeoxyglucose positron-emission tomography/computed tomography ( 18 F-FDG PET/CT) in assessing locoregional nodal status for initial staging of breast cancer has not yet been well-defined in clinical practice. In the current report, we describe a new PET probe-based clinical approach, with evaluation of the technical performance of a handheld high-energy gamma probe for intraoperative localization of breast carcinomas, and evaluation of lymph node metastases during radio-guided oncological surgery. Three patients underwent a PET/CT scan immediately prior to surgery following the standard clinical protocol. Intraoperatively, tumors were localized and resected with the assistance of a hand-held gamma probe. PET-guided assessment of the presence or absence of regional nodal spread of malignancy was compared with the reference standard of histopathological examination. In all three cases, perioperative 18 F-FDG PET/CT imaging and intraoperative gamma probe detection verified complete resection of the hypermetabolic lesions and demonstrated no additional suspicious occult disease. This innovative approach demonstrates great promise for providing real-time access to metabolic and morphological tumor information that may lead to an optimal disease-tailored approach. In carefully selected indications, a PET probe can be a useful adjunct in surgical practice, but further trials with a larger number of patients need to be performed to verify these findings. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  4. Adding Bite to the Bark: Using LibGuides2 Migration as Impetus to Introduce Strong Content Standards

    ERIC Educational Resources Information Center

    Fritch, Melia; Pitts, Joelle E.

    2016-01-01

    The authors discuss the long-term accumulation of unstandardized and inaccessible content within the Libguides system and the decision-making process to create and implement a set of standards using the migration to the LibGuides2 platform as a vehicle for change. Included in the discussion are strategies for the creation of standards and…

  5. Beable-guided quantum theories: Generalizing quantum probability laws

    NASA Astrophysics Data System (ADS)

    Kent, Adrian

    2013-02-01

    Beable-guided quantum theories (BGQT) are generalizations of quantum theory, inspired by Bell's concept of beables. They modify the quantum probabilities for some specified set of fundamental events, histories, or other elements of quasiclassical reality by probability laws that depend on the realized configuration of beables. For example, they may define an additional probability weight factor for a beable configuration, independent of the quantum dynamics. Beable-guided quantum theories can be fitted to observational data to provide foils against which to compare explanations based on standard quantum theory. For example, a BGQT could, in principle, characterize the effects attributed to dark energy or dark matter, or any other deviation from the predictions of standard quantum dynamics, without introducing extra fields or a cosmological constant. The complexity of the beable-guided theory would then parametrize how far we are from a standard quantum explanation. Less conservatively, we give reasons for taking suitably simple beable-guided quantum theories as serious phenomenological theories in their own right. Among these are the possibility that cosmological models defined by BGQT might in fact fit the empirical data better than any standard quantum explanation, and the fact that BGQT suggest potentially interesting nonstandard ways of coupling quantum matter to gravity.

  6. MR-guided radiofrequency ablation of hepatic malignancies at 1.5 T: initial results.

    PubMed

    Mahnken, Andreas H; Buecker, Arno; Spuentrup, Elmar; Krombach, Gabriele A; Henzler, Dietrich; Günther, Rolf W; Tacke, Josef

    2004-03-01

    To assess the feasibility of magnetic resonance (MR)-guided radiofrequency ablation (RFA) of hepatic malignancies using a high-field MR scanner. A total of 10 patients with 14 primary (N = 1) or secondary (N = 13) hepatic malignancies underwent MR-guided RFA using a closed-bore 1.5 T MR scanner. Lesion diameters ranged from 2.0 cm to 4.7 cm. RFA was performed using a 200-W generator in combination with a 3.5-cm LeVeen electrode applying a standardized energy protocol. RFA was technically feasible in all patients. Necrosis diameter ranged from 2.5 cm to 6.8 cm. The mean follow-up period is 12.2 (1-18) months. In nine out of 10 patients, local tumor control was achieved. For this purpose, a second CT-guided RFA was required in two patients. In four patients, multifocal hepatic tumor progression occurred, with the treated lesion remaining tumor-free in three of these patients. Two patients showed extrahepatic tumor progression. Four patients remained tumor-free. No major complications occurred. MR-guided RFA of hepatic malignancies in a closed-bore high-field MR scanner is technically feasible and safe. It can be advantageous in locations considered unfavorable for CT-guided puncture or in patients in which iodinated contrast material is contraindicated. Copyright 2004 Wiley-Liss, Inc.

  7. Specific NIST projects in support of the NIJ Concealed Weapon Detection and Imaging Program

    NASA Astrophysics Data System (ADS)

    Paulter, Nicholas G.

    1998-12-01

    The Electricity Division of the National Institute of Standards and Technology is developing revised performance standards for hand-held (HH) and walk-through (WT) metal weapon detectors, test procedures and systems for these detectors, and a detection/imaging system for finding concealed weapons. The revised standards will replace the existing National Institute of Justice (NIJ) standards for HH and WT devices and will include detection performance specifications as well as system specifications (environmental conditions, mechanical strength and safety, response reproducibility and repeatability, quality assurance, test reporting, etc.). These system requirements were obtained from the Law Enforcement and corrections Technology Advisory Council, an advisory council for the NIJ. Reproducible and repeatable test procedures and appropriate measurement systems will be developed for evaluating HH and WT detection performance. A guide to the technology and application of non- eddy-current-based detection/imaging methods (such as acoustic, passive millimeter-wave and microwave, active millimeter-wave and terahertz-wave, x-ray, etc.) Will be developed. The Electricity Division is also researching the development of a high- frequency/high-speed (300 GH to 1 THz) pulse-illuminated, stand- off, video-rate, concealed weapons/contraband imaging system.

  8. Initial laboratory experience with a novel ultrasound probe for standard and single-port robotic kidney surgery: increasing console surgeon autonomy and minimizing instrument clashing.

    PubMed

    Yakoubi, Rachid; Autorino, Riccardo; Laydner, Humberto; Guillotreau, Julien; White, Michael A; Hillyer, Shahab; Spana, Gregory; Khanna, Rakesh; Isaac, Wahib; Haber, Georges-Pascal; Stein, Robert J; Kaouk, Jihad H

    2012-06-01

    The aim of this study was to evaluate a novel ultrasound probe specifically developed for robotic surgery by determining its efficiency in identifying renal tumors. The study was carried out using the Da Vinci™ surgical system in one female pig. Renal tumor targets were created by percutaneous injection of a tumor mimic mixture. Single-port and standard robotic partial nephrectomy were performed. Intraoperative ultrasound was performed using both standard laparoscopic probe and the new ProART™ Robotic probe. Probe maneuverability and ease of handling for tumor localization were recorded. The standard laparoscopic probe was guided by the assistant. Significant clashing with robotic arms was noted during the single-port procedure. The novel robotic probe was easily introduced through the assistant trocar, and held by the console surgeon using the robotic Prograsp™ with no registered clashing in the external operative field. The average time for grasping the new robotic probe was less than 10 s. Once inserted and grasped, no limitation was found in terms of instrument clashing during the single-port procedure. This novel ultrasound probe developed for robotic surgery was noted to be user-friendly when performing porcine standard and especially single-port robotic partial nephrectomy. Copyright © 2011 John Wiley & Sons, Ltd.

  9. Kent County Health Department: Using an Agency Strategic Plan to Drive Improvement.

    PubMed

    Saari, Chelsey K

    The Kent County Health Department (KCHD) was accredited by the Public Health Accreditation Board (PHAB) in September 2014. Although Michigan has had a state-level accreditation process for local health departments since the late 1990s, the PHAB accreditation process presented a unique opportunity for KCHD to build on successes achieved through state accreditation and enhance performance in all areas of KCHD programs, services, and operations. PHAB's standards, measures, and peer-review process provided a standardized and structured way to identify meaningful opportunities for improvement and to plan and implement strategies for enhanced performance and established a platform for being recognized nationally as a high-performing local health department. The current case report highlights the way in which KCHD has developed and implemented its strategic plan to guide efforts aimed at addressing gaps identified through the accreditation process and to drive overall improvement within our agency.

  10. Wide-bore 1.5 T MRI-guided deep brain stimulation surgery: initial experience and technique comparison.

    PubMed

    Sillay, Karl A; Rusy, Deborah; Buyan-Dent, Laura; Ninman, Nancy L; Vigen, Karl K

    2014-12-01

    We report results of the initial experience with magnetic resonance image (MRI)-guided implantation of subthalamic nucleus (STN) deep brain stimulating (DBS) electrodes at the University of Wisconsin after having employed frame-based stereotaxy with previously available MR imaging techniques and microelectrode recording for STN DBS surgeries. Ten patients underwent MRI-guided DBS implantation of 20 electrodes between April 2011 and March 2013. The procedure was performed in a purpose-built intraoperative MRI suite configured specifically to allow MRI-guided DBS, using a wide-bore (70 cm) MRI system. Trajectory guidance was accomplished with commercially available system consisting of an MR-visible skull-mounted aiming device and a software guidance system processing intraoperatively acquired iterative MRI scans. A total of 10 patients (5 male, 5 female)-representative of the Parkinson Disease (PD) population-were operated on with standard technique and underwent 20 electrode placements under MRI-guided bilateral STN-targeted DBS placement. All patients completed the procedure with electrodes successfully placed in the STN. Procedure time improved with experience. Our initial experience confirms the safety of MRI-guided DBS, setting the stage for future investigations combining physiology and MRI guidance. Further follow-up is required to compare the efficacy of the MRI-guided surgery cohort to that of traditional frame-based stereotaxy. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Vaginal gamete intrafallopian transfer. Experience with 14 cases.

    PubMed

    Lucena, E; Paulson, J D; Ruiz, J; Asmar, P; Mendoza, J C; Ortiz, J A; Gomez, M; Arango, A; Lucena, C; Lucena, A

    1990-06-01

    A procedure utilizing transvaginal aspiration of stimulated gametes followed by transcervical, ultrasound-guided catheterization of the tubal ostia was performed as a modification of the standardized gamete intrafallopian transfer (GIFT) technique. Among 14 patients with 16 cycles there were four normal, intrauterine pregnancies and one ectopic pregnancy. In two patients the beta-human gonadotropin level rose significantly and then started to fall; the patients aborted spontaneously. The procedure can be performed with a higher degree of patient acceptance than can traditional GIFT, and the success rate in this small series was promising.

  12. An Audiovisual Teaching Module to Assist Examiners in the Administration of a Practical Performance Examination for the Emergency Medical Technician-Ambulance (EMT-A). Consisting of a 90-Minute Audiovisual Presentation In Either 16mm Sound or 3/4" Video-Cassette Plus a "User's Guide" Describing in Detail the Total Examination Procedure. Final Report.

    ERIC Educational Resources Information Center

    National Registry of Emergency Medical Technicians, Columbus, OH.

    A structured, time-referenced, performance examination was designed as part of the certification procedure for Emergency Medical Technicians-Ambulance in an attempt to increase objectivity and standardization. This examination is based on a model developed by the University of Southern California, School of Medicine, Department of Emergency…

  13. The Fluidez en La Lectura Oral (FLO) Portion of the Indicadores Dinamicos De Exito en La Lectura (IDEL) and the English Language Portion of the Illinois Standard Achievement Test (ISAT): A Correlational Study of Second and Third Grade English Language Learners

    ERIC Educational Resources Information Center

    Ganan, Brian J.

    2012-01-01

    This study examined the relationship between Spanish oral reading fluency (ORF) at the end of second grade and students' performance on the third grade ISAT reading test. The major research question guiding this study was: What is the direction and strength of the relationship between performance on the 2nd grade IDEL FLO, a Spanish language ORF…

  14. A Randomized Controlled Trial Evaluating the See, Tilt, Align, and Rotate (STAR) Maneuver on Skill Acquisition for Simulated Ultrasound-Guided Interventional Procedures.

    PubMed

    Lam, Nicholas C K; Fishburn, Steven J; Hammer, Angie R; Petersen, Timothy R; Gerstein, Neal S; Mariano, Edward R

    2015-06-01

    Achieving the best view of the needle and target anatomy when performing ultrasound-guided interventional procedures requires technical skill, which novices may find difficult to learn. We hypothesized that teaching novice performers to use 4 sequential steps (see, tilt, align, and rotate [STAR] method) to identify the needle under ultrasound guidance is more efficient than training with the commonly described probe movements of align, rotate, and tilt (ART). This study compared 2 instructional methods for transducer manipulation including alignment of a probe and needle by novices during a simulated ultrasound-guided nerve block. Right-handed volunteers between the ages of 18 and 55 years who had no previous ultrasound experience were recruited and randomized to 1 of 2 groups; one group was trained to troubleshoot misalignment with the ART method, and the other was trained with the new STAR maneuver. Participants performed the task, consisting of directing a needle in plane to 3 targets in a standardized gelatin phantom 3 times. The performance assessor and data analyst were blinded to group assignment. Thirty-five participants were recruited. The STAR group was able to complete the task more quickly (P < .001) and visualized the needle in a greater proportion of the procedure time (P = .004) compared to the ART group. All STAR participants were able to complete the task, whereas 41% of ART participants abandoned the task (P = .003). Novices are able to complete a simulated ultrasound-guided nerve block more quickly and efficiently when trained with the 4-step STAR maneuver compared to the ART method. © 2015 by the American Institute of Ultrasound in Medicine.

  15. Predicting activities of daily living for cancer patients using an ontology-guided machine learning methodology.

    PubMed

    Min, Hua; Mobahi, Hedyeh; Irvin, Katherine; Avramovic, Sanja; Wojtusiak, Janusz

    2017-09-16

    Bio-ontologies are becoming increasingly important in knowledge representation and in the machine learning (ML) fields. This paper presents a ML approach that incorporates bio-ontologies and its application to the SEER-MHOS dataset to discover patterns of patient characteristics that impact the ability to perform activities of daily living (ADLs). Bio-ontologies are used to provide computable knowledge for ML methods to "understand" biomedical data. This retrospective study included 723 cancer patients from the SEER-MHOS dataset. Two ML methods were applied to create predictive models for ADL disabilities for the first year after a patient's cancer diagnosis. The first method is a standard rule learning algorithm; the second is that same algorithm additionally equipped with methods for reasoning with ontologies. The models showed that a patient's race, ethnicity, smoking preference, treatment plan and tumor characteristics including histology, staging, cancer site, and morphology were predictors for ADL performance levels one year after cancer diagnosis. The ontology-guided ML method was more accurate at predicting ADL performance levels (P < 0.1) than methods without ontologies. This study demonstrated that bio-ontologies can be harnessed to provide medical knowledge for ML algorithms. The presented method demonstrates that encoding specific types of hierarchical relationships to guide rule learning is possible, and can be extended to other types of semantic relationships present in biomedical ontologies. The ontology-guided ML method achieved better performance than the method without ontologies. The presented method can also be used to promote the effectiveness and efficiency of ML in healthcare, in which use of background knowledge and consistency with existing clinical expertise is critical.

  16. Photovoltaic Calibrations at the National Renewable Energy Laboratory and Uncertainty Analysis Following the ISO 17025 Guidelines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Emery, Keith

    The measurement of photovoltaic (PV) performance with respect to reference conditions requires measuring current versus voltage for a given tabular reference spectrum, junction temperature, and total irradiance. This report presents the procedures implemented by the PV Cell and Module Performance Characterization Group at the National Renewable Energy Laboratory (NREL) to achieve the lowest practical uncertainty. A rigorous uncertainty analysis of these procedures is presented, which follows the International Organization for Standardization (ISO) Guide to the Expression of Uncertainty in Measurement. This uncertainty analysis is required for the team’s laboratory accreditation under ISO standard 17025, “General Requirements for the Competence ofmore » Testing and Calibration Laboratories.” The report also discusses additional areas where the uncertainty can be reduced.« less

  17. Patient-specific targeting guides compared with traditional instrumentation for glenoid component placement in shoulder arthroplasty: a multi-surgeon study in 70 arthritic cadaver specimens.

    PubMed

    Throckmorton, Thomas W; Gulotta, Lawrence V; Bonnarens, Frank O; Wright, Stephen A; Hartzell, Jeffrey L; Rozzi, William B; Hurst, Jason M; Frostick, Simon P; Sperling, John W

    2015-06-01

    The purpose of this study was to compare the accuracy of patient-specific guides for total shoulder arthroplasty (TSA) with traditional instrumentation in arthritic cadaver shoulders. We hypothesized that the patient-specific guides would place components more accurately than standard instrumentation. Seventy cadaver shoulders with radiographically confirmed arthritis were randomized in equal groups to 5 surgeons of varying experience levels who were not involved in development of the patient-specific guidance system. Specimens were then randomized to patient-specific guides based off of computed tomography scanning, standard instrumentation, and anatomic TSA or reverse TSA. Variances in version or inclination of more than 10° and more than 4 mm in starting point were considered indications of significant component malposition. TSA glenoid components placed with patient-specific guides averaged 5° of deviation from the intended position in version and 3° in inclination; those with standard instrumentation averaged 8° of deviation in version and 7° in inclination. These differences were significant for version (P = .04) and inclination (P = .01). Multivariate analysis of variance to compare the overall accuracy for the entire cohort (TSA and reverse TSA) revealed patient-specific guides to be significantly more accurate (P = .01) for the combined vectors of version and inclination. Patient-specific guides also had fewer instances of significant component malposition than standard instrumentation did. Patient-specific targeting guides were more accurate than traditional instrumentation and had fewer instances of component malposition for glenoid component placement in this multi-surgeon cadaver study of arthritic shoulders. Long-term clinical studies are needed to determine if these improvements produce improved functional outcomes. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  18. MATE standardization

    NASA Astrophysics Data System (ADS)

    Farmer, R. E.

    1982-11-01

    The MATE (Modular Automatic Test Equipment) program was developed to combat the proliferation of unique, expensive ATE within the Air Force. MATE incorporates a standard management approach and a standard architecture designed to implement a cradle-to-grave approach to the acquisition of ATE and to significantly reduce the life cycle cost of weapons systems support. These standards are detailed in the MATE Guides. The MATE Guides assist both the Air Force and Industry in implementing the MATE concept, and provide the necessary tools and guidance required for successful acquisition of ATE. The guides also provide the necessary specifications for industry to build MATE-qualifiable equipment. The MATE architecture provides standards for all key interfaces of an ATE system. The MATE approach to the acquisition and management of ATE has been jointly endorsed by the commanders of Air Force Systems Command and Air Force Logistics Command as the way of doing business in the future.

  19. The development of a highly constrained health level 7 implementation guide to facilitate electronic laboratory reporting to ambulatory electronic health record systems.

    PubMed

    Sujansky, Walter V; Overhage, J Marc; Chang, Sophia; Frohlich, Jonah; Faus, Samuel A

    2009-01-01

    Electronic laboratory interfaces can significantly increase the value of ambulatory electronic health record (EHR) systems by providing laboratory result data automatically and in a computable form. However, many ambulatory EHRs cannot implement electronic laboratory interfaces despite the existence of messaging standards, such as Health Level 7, version 2 (HL7). Among several barriers to implementing laboratory interfaces is the extensive optionality within the HL7 message standard. This paper describes the rationale for and development of an HL7 implementation guide that seeks to eliminate most of the optionality inherent in HL7, but retain the information content required for reporting outpatient laboratory results. A work group of heterogeneous stakeholders developed the implementation guide based on a set of design principles that emphasized parsimony, practical requirements, and near-term adoption. The resulting implementation guide contains 93% fewer optional data elements than HL7. This guide was successfully implemented by 15 organizations during an initial testing phase and has been approved by the HL7 standards body as an implementation guide for outpatient laboratory reporting. Further testing is required to determine whether widespread adoption of the implementation guide by laboratories and EHR systems can facilitate the implementation of electronic laboratory interfaces.

  20. Diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysis.

    PubMed

    Oh, Hyoung-Chul; Kang, Hyun; Lee, Jae Young; Choi, Geun Joo; Choi, Jung Sik

    2016-11-01

    To compare the diagnostic accuracy of endoscopic ultrasound-guided core needle aspiration with that of standard fine-needle aspiration by systematic review and meta-analysis. Studies using 22/25-gauge core needles, irrespective of comparison with standard fine needles, were comprehensively reviewed. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and summary receiver operating characteristic curves for the diagnosis of malignancy were used to estimate the overall diagnostic efficiency. The pooled sensitivity, specificity, and DOR of the core needle for the diagnosis of malignancy were 0.88 (95% confidence interval [CI], 0.84 to 0.90), 0.99 (95% CI, 0.96 to 1), and 167.37 (95% CI, 65.77 to 425.91), respectively. The pooled sensitivity, specificity, and DOR of the standard needle were 0.84 (95% CI, 0.79 to 0.88), 1 (95% CI, 0.97 to 1), and 130.14 (95% CI, 34.00 to 495.35), respectively. The area under the curve of core and standard needle in the diagnosis of malignancy was 0.974 and 0.955, respectively. The core and standard needle were comparable in terms of pancreatic malignancy diagnosis. There was no significant difference in procurement of optimal histologic cores between core and standard needles (risk ratio [RR], 0.545; 95% CI, 0.187 to 1.589). The number of needle passes for diagnosis was significantly lower with the core needle (standardized mean difference, -0.72; 95% CI, -1.02 to -0.41). There were no significant differences in overall complications (RR, 1.26; 95% CI, 0.34 to 4.62) and technical failure (RR, 5.07; 95% CI, 0.68 to 37.64). Core and standard needles were comparable in terms of diagnostic accuracy, technical performance, and safety profile.

  1. The guide to Design For On-orbit Spacecraft Servicing (DFOSS) manual: Producing a consensus document

    NASA Technical Reports Server (NTRS)

    Nyman, Janice

    1993-01-01

    Increasing interaction and changing economies at the national and international levels have accelerated the call for standardization in space systems design. The benefits of standardization--compatibility, interchangeability, and lower costs--are maximized when achieved through consensus. Reaching consensus in standardization means giving everyone who will be affected by a standard an opportunity to have input into creating that standard. The DFOSS manual was initiated with the goal of developing standards through consensus. The present Proposed Guide derives from work begun by the Space Automation and Robotics Center (SpARC), a NASA Center for the Commercial Development of Space, and has continued as a standards project through the American Institute of Aeronautics and Astronautics (AIAA). The Proposed Guide was released by AIAA in Jan. 1992 for sale during a one-year, trial-use period. DFOSS is a response to the need for one document that contains all the guidelines required by on-orbit spacecraft servicing designers for astronaut extravehicular activity and/or telerobotic servicing. The manual's content is driven by spacecraft design considerations, and its composition has been achieved by interaction and cooperation among government, industry, and research organizations. While much work lies ahead to maximize the potential of DFOSS, the Proposed Guide represents evidence of the benefits of industry-wide consensus, points the way for broader application, and provides an example for similar projects.

  2. Standardized Curriculum for Outboard Marine Engine Mechanics.

    ERIC Educational Resources Information Center

    Mississippi State Dept. of Education, Jackson. Office of Vocational, Technical and Adult Education.

    This curriculum guide for outboard marine engine mechanics was developed by the state of Mississippi to standardize vocational education course titles and core contents. The objectives contained in this document are common to all outboard marine engine mechanics programs in the state. The guide contains objectives for outboard marine engine…

  3. Mathematics. Arkansas Public School Course Content Guide.

    ERIC Educational Resources Information Center

    Arkansas State Dept. of Education, Little Rock.

    The standards for accreditation of public schools, adopted by the Arkansas State Board of Education, required the development of these course content guides. The standards also required that essential skills be identified for each course taught in the public schools of Arkansas. Committees of classroom teachers, curriculum specialists, principals,…

  4. WWC Study Review Guide: Group Design Studies

    ERIC Educational Resources Information Center

    What Works Clearinghouse, 2018

    2018-01-01

    Underlying all What Works Clearinghouse (WWC) products are WWC Study Review Guides, which are intended for use by WWC certified reviewers to assess studies against the WWC evidence standards. As part of an ongoing effort to increase transparency, promote collaboration, and encourage widespread use of the WWC standards, the Institute of Education…

  5. Culinary Arts Hospitality Symposium Planning Guide.

    ERIC Educational Resources Information Center

    Borgie, Karen; Wang, Yeimei

    This guide was developed as part of a project to standardize California's statewide culinary arts curriculum based on industry guidelines and standards. It details a process that California community colleges can use to plan a hospitality symposium that will accomplish the following objectives: provide students with a forum to demonstrate their…

  6. Key Skills Portfolio Assessment: Good Practice Guide

    ERIC Educational Resources Information Center

    Rolfe, Martin; Wilson, Lorraine

    2007-01-01

    This guide offers advice and guidance to key skills managers, coordinators and other practitioners who are responsible for ensuring that the standards of portfolio assessment in their center are consistent across the center and with national standards. It describes and offers advice and guidance on the stages of assessment and internal moderation…

  7. 77 FR 25721 - Small Entity Compliance Guide: Bottled Water: Quality Standard: Establishing an Allowable Level...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-01

    ...] Small Entity Compliance Guide: Bottled Water: Quality Standard: Establishing an Allowable Level for di(2-ethylhexyl)phthalate; Availability AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food and Drug Administration (FDA) is announcing the availability of a guidance for industry entitled...

  8. A Guide to Developing Collaborative School-Community-Business Partnerships

    ERIC Educational Resources Information Center

    Luecking, Richard; Deschamps, Ann; Allison, Ruth; Hyatt, Jacque; Stuart, Christy

    2015-01-01

    The "gold standard" of youth outcomes is when they are achieving employment and pursuing a clear career path. The activities transition and employment initiatives, and the partnerships that support them, are most appropriately judged against this standard. This Guide presents approaches and considerations for the development and…

  9. Standardized Curriculum for Service Station Retailing.

    ERIC Educational Resources Information Center

    Mississippi State Dept. of Education, Jackson. Office of Vocational, Technical and Adult Education.

    This curriculum guide for service station retailing was developed by the state of Mississippi to standardize vocational education course titles and core contents. The objectives contained in this document are common to all service station retailing programs in the state. The guide contains objectives for service station retailing I and II courses.…

  10. Self-Study and Evaluation Guide/Revised 1979. Section C-1: Function and Structure.

    ERIC Educational Resources Information Center

    National Accreditation Council for Agencies Serving the Blind and Visually Handicapped, New York, NY.

    The self study guide designed for accreditation of programs serving the blind and visually handicapped covers function and structure standards, standards address five areas: basic characteristics of the organization (legal base, planning, consumer rights), governing authority, the Chief administrator, basic administrative structure (fees for…

  11. Percutaneous CT-guided biopsy of the spine: results of 430 biopsies

    PubMed Central

    Rimondi, Eugenio; Errani, Costantino; Bianchi, Giuseppe; Casadei, Roberto; Alberghini, Marco; Malaguti, Maria Cristina; Rossi, Giuseppe; Durante, Stefano; Mercuri, Mario

    2008-01-01

    Biopsies of lesions in the spine are often challenging procedures with significant risk of complications. CT-guided needle biopsies could lower these risks but uncertainties still exist about the diagnostic accuracy. Aim of this retrospective study was to evaluate the diagnostic accuracy of CT-guided needle biopsies for bone lesions of the spine. We retrieved the results of 430 core needle biopsies carried out over the past fifteen years at the authors’ institute and examined the results obtained. Of the 430 biopsies performed, in 401 cases the right diagnosis was made with the first CT-guided needle biopsy (93.3% accuracy rate). Highest accuracy rates were obtained in primary and secondary malignant lesions. Most false negative results were found in cervical lesions and in benign, pseudotumoral, inflammatory, and systemic pathologies. There were only 9 complications (5 transient paresis, 4 haematomas that resolved spontaneously) that had no influence on the treatment strategy, nor on the patient’s outcome. In conclusion we can assert that this technique is reliable and safe and should be considered the gold standard in biopsies of the spine. PMID:18463900

  12. TRIDENT II (D-5) Strategic Weapon System Guide for Potential Subcontractors.

    DTIC Science & Technology

    1982-01-01

    pattern. Usually high technology item subcontracts are the first selected, This is followed by crit- ical, special long-lead time, common, and...performance. These disciplines provide the program with a definitive approach to maintaining high standards of reliability and readiness for weapon system...missile itself will be increased in length and diameter.. The range of the missile will be enhanced, and it will carry an increased payload. Energy

  13. IceT users' guide and reference.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moreland, Kenneth D.

    2011-01-01

    The Image Composition Engine for Tiles (IceT) is a high-performance sort-last parallel rendering library. In addition to providing accelerated rendering for a standard display, IceT provides the unique ability to generate images for tiled displays. The overall resolution of the display may be several times larger than any viewport that may be rendered by a single machine. This document is an overview of the user interface to IceT.

  14. Statistical validation of brain tumor shape approximation via spherical harmonics for image-guided neurosurgery.

    PubMed

    Goldberg-Zimring, Daniel; Talos, Ion-Florin; Bhagwat, Jui G; Haker, Steven J; Black, Peter M; Zou, Kelly H

    2005-04-01

    Surgical planning now routinely uses both two-dimensional (2D) and three-dimensional (3D) models that integrate data from multiple imaging modalities, each highlighting one or more aspects of morphology or function. We performed a preliminary evaluation of the use of spherical harmonics (SH) in approximating the 3D shape and estimating the volume of brain tumors of varying characteristics. Magnetic resonance (MR) images from five patients with brain tumors were selected randomly from our MR-guided neurosurgical practice. Standardized mean square reconstruction errors (SMSRE) by tumor volume were measured. Validation metrics for comparing performances of the SH method against segmented contours (SC) were the dice similarity coefficient (DSC) and standardized Euclidean distance (SED) measure. Tumor volume range was 22,413-85,189 mm3, and range of number of vertices in triangulated models was 3674-6544. At SH approximations with degree of at least 30, SMSRE were within 1.66 x 10(-5) mm(-1). Summary measures yielded a DSC range of 0.89-0.99 (pooled median, 0.97 and significantly >0.7; P < .001) and an SED range of 0.0002-0.0028 (pooled median, 0.0005). 3D shapes of tumors may be approximated by using SH for neurosurgical applications.

  15. The Role of the Caudal Superior Parietal Lobule in Updating Hand Location in Peripheral Vision: Further Evidence from Optic Ataxia

    PubMed Central

    Granek, Joshua A.; Pisella, Laure; Blangero, Annabelle; Rossetti, Yves; Sergio, Lauren E.

    2012-01-01

    Patients with optic ataxia (OA), who are missing the caudal portion of their superior parietal lobule (SPL), have difficulty performing visually-guided reaches towards extra-foveal targets. Such gaze and hand decoupling also occurs in commonly performed non-standard visuomotor transformations such as the use of a computer mouse. In this study, we test two unilateral OA patients in conditions of 1) a change in the physical location of the visual stimulus relative to the plane of the limb movement, 2) a cue that signals a required limb movement 180° opposite to the cued visual target location, or 3) both of these situations combined. In these non-standard visuomotor transformations, the OA deficit is not observed as the well-documented field-dependent misreach. Instead, OA patients make additional eye movements to update hand and goal location during motor execution in order to complete these slow movements. Overall, the OA patients struggled when having to guide centrifugal movements in peripheral vision, even when they were instructed from visual stimuli that could be foveated. We propose that an intact caudal SPL is crucial for any visuomotor control that involves updating ongoing hand location in space without foveating it, i.e. from peripheral vision, proprioceptive or predictive information. PMID:23071599

  16. AAALAC International Standards and Accreditation Process

    PubMed Central

    Gettayacamin, Montip; Retnam, Leslie

    2017-01-01

    AAALAC International is a private, nonprofit organization that promotes humane treatment of animals in science through a voluntary international accreditation program. AAALAC International accreditation is recognized around the world as a symbol of high quality animal care and use for research, teaching and testing, as well as promoting animal welfare. Animals owned by the institution that are used for research, teaching and testing are included as part of an accredited program. More than 990 animal care and use institutions in 42 countries around the world (more than 170 programs in 13 countries in the Pacific Rim region) have earned AAALAC International accreditation. The AAALAC International Council on Accreditation evaluates overall performance and all aspects of an animal care and use program, involving an in-depth, multilayered, confidential peer-review process. The evaluators (site visitors) consider compliance with applicable local animal legislation of the host country, institutional policies, and employ a customized approach for evaluating overall program performance using a series of primary standards that include the Guide for the Care and Use of Laboratory Animals, the Guide for the Care and Use of Agricultural Animals in Research and Teaching, or the European Convention for the Protection of Vertebrate Animals Used for Experimental and Other Purposes, Council of Europe (ETS 123), and supplemental Reference Resources, as applicable. PMID:28744349

  17. The role of ultrasound guidance in pediatric caudal block

    PubMed Central

    Erbüyün, Koray; Açıkgöz, Barış; Ok, Gülay; Yılmaz, Ömer; Temeltaş, Gökhan; Tekin, İdil; Tok, Demet

    2016-01-01

    Objectives: To compare the time interval of the procedure, possible complications, post-operative pain levels, additional analgesics, and nurse satisfaction in ultrasonography-guided and standard caudal block applications. Methods: This retrospective study was conducted in Celal Bayar University Hospital, Manisa, Turkey, between January and December 2014, included 78 pediatric patients. Caudal block was applied to 2 different groups; one with ultrasound guide, and the other using the standard method. Results: The time interval of the procedure was significantly shorter in the standard application group compared with ultrasound-guided group (p=0.020). Wong-Baker FACES Pain Rating Scale values obtained at the 90th minute was statistically lower in the standard application group compared with ultrasound-guided group (p=0.035). No statistically significant difference was found on the other parameters between the 2 groups. The shorter time interval of the procedure at standard application group should not be considered as a distinctive mark by the pediatric anesthesiologists, because this time difference was as short as seconds. Conclusion: Ultrasound guidance for caudal block applications would neither increase nor decrease the success of the treatment. However, ultrasound guidance should be needed in cases where the detection of sacral anatomy is difficult, especially by palpations. PMID:26837396

  18. Recreational Pilot and Private Pilot Knowledge Test Guide

    DOT National Transportation Integrated Search

    1995-01-01

    The Flight Standards Service of the Federal Aviation Administration (FAA) has developed this guide to help : applicants meet the knowledge requirements for recreational pilot and private pilot certification. : This guide contains information about el...

  19. A novel stereotactic frame for real PET-guided biopsies: A preclinical proof-of-concept.

    PubMed

    Cortes-Rodicio, J; Sanchez-Merino, G; Garcia-Fidalgo, M A; Tobalina-Larrea, I

    2017-09-01

    To design, build and test a stereotactic device that allows PET image-guided biopsies to be performed. An initial prototype consisting of four main pieces, one of which contains radioactive markers to make it visible in the PET images, was built using a 3D printer. Once the device is mounted, a spherical coordinate system is built with the entrance needle point in the skin as the origin of coordinates. Two in-house software programs, namely getCoord.ijm, which obtains the spherical coordinates of the tumour tissue to be biopsied, and getNeedle.ijm, which virtualizes the inner needle tip once the puncture has taken place, were written. This prototype was tested on an FDG-doped phantom to characterize both the accuracy of the system and the procedure time. Up to 11 complete biopsy procedures were conducted. The mean total procedure time was less than 20min, which is less than the procedure time of conventional standard CT-guided biopsies. The overall accuracy of the system was found to be 5.0±1.3mm, which outperforms the criterion used in routine clinical practice when targeting tumours with a diameter of 10mm. A stereotactic frame to conduct real PET image-guided biopsies has been designed and built. A proof-of-concept was performed to characterize the system. The procedure time and accuracy of the system were found to meet the current needs of physicians performing biopsies. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  20. Criteria to Evaluate Interpretive Guides for Criterion-Referenced Tests

    ERIC Educational Resources Information Center

    Trapp, William J.

    2007-01-01

    This project provides a list of criteria for which the contents of interpretive guides written for customized, criterion-referenced tests can be evaluated. The criteria are based on the "Standards for Educational and Psychological Testing" (1999) and examine the content breadth of interpretive guides. Interpretive guides written for…

  1. Precision Machining Technology. Curriculum Guide.

    ERIC Educational Resources Information Center

    Idaho State Dept. of Education, Boise. Div. of Vocational Education.

    This curriculum guide was developed from a Technical Committee Report prepared with the assistance of industry personnel and containing a Task List which is the basis of the guide. It presents competency-based program standards for courses in precision machining technology and is part of the Idaho Vocational Curriculum Guide Project, a cooperative…

  2. Anti-Propionibacterium acnes assay-guided purification of brazilin and preparation of brazilin rich extract from Caesalpinia sappan heartwood.

    PubMed

    Nirmal, Nilesh Prakash; Panichayupakaranant, Pharkphoom

    2014-09-01

    Caesalpinia sappan L. (Leguminosae or Fabaceae) heartwood has been used as a coloring agent, with antibacterial activity in food, beverages, cosmetics, and garments. To purify brazilin from C. sappan heartwood and use it as a standard marker for the preparation and standardization of an active constituent-rich extract. Crude ethanol extracts of C. sappan heartwood (CSE) were fractionated to isolate brazilin by an anti-P. acnes assay-guided isolation. Quantitative analysis was performed by HPLC. Minimum inhibitory concentrations (MICs) and minimum bactericidal concentrations (MBCs) were determined by the broth microdilution method. Brazilin isolated from CSE possessed antibacterial activity against P. acnes with MIC and MBC values of 15.6 and 31.2 µg/mL, respectively. Brazilin was, therefore, used as a standard marker for standardization and preparation of a brazilin rich extract (BRE). BRE was prepared from CSE using a simple one-step purification using a macroporous resin column eluted with 35% v/v ethanol. This method increased the brazilin content in the BRE up to 39.9% w/w. The antibacterial activity of the standardized BRE against acne involved bacteria was higher than for the CSE but lower than brazilin. However, for industrial applications, a large-scale one-step preparation of BRE has more advantages than the use of pure brazilin in terms of convenience and a low-cost production process. Therefore, BRE is considered as a potential coloring agent with antibacterial activity which is used for pharmaceutical, cosmetic, and nutraceutical applications.

  3. Measure Guideline: Ventilation Guidance for Residential High-Performance New Construction - Multifamily

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lstiburek, Joseph

    2017-01-01

    The measure guideline provides ventilation guidance for residential high performance multifamily construction that incorporates the requirements of the ASHRAE 62.2 ventilation and indoor air quality standard. The measure guideline focus is on the decision criteria for weighing cost and performance of various ventilation systems. The measure guideline is intended for contractors, builders, developers, designers and building code officials. The guide may also be helpful to building owners wishing to learn more about ventilation strategies available for their buildings. The measure guideline includes specific design and installation instructions for the most cost effective and performance effective solutions for ventilation in multifamilymore » units that satisfies the requirements of ASHRAE 62.2-2016.« less

  4. Measure Guideline: Ventilation Guidance for Residential High-Performance New Construction - Multifamily

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lstiburek, Joseph

    The measure guideline provides ventilation guidance for residential high performance multifamily construction that incorporates the requirements of the ASHRAE 62.2 ventilation and indoor air quality standard. The measure guideline focus is on the decision criteria for weighing cost and performance of various ventilation systems. The measure guideline is intended for contractors, builders, developers, designers and building code officials. The guide may also be helpful to building owners wishing to learn more about ventilation strategies available for their buildings. The measure guideline includes specific design and installation instructions for the most cost effective and performance effective solutions for ventilation in multifamilymore » units that satisfies the requirements of ASHRAE 62.2-2016.« less

  5. Construction of a standard test assembly for controlled laser studies in tissues: Preliminary study on human bone material

    NASA Astrophysics Data System (ADS)

    Beer, Franziska; Passow, Harald

    2008-02-01

    The aim of the study is the construction of a test assembly, which facilitates objective, comparative studies on the cutting performance of lasers in hard tissue. To ensure the applicability of our own construction for the reproducible performance of laser incisions in hard tissue, eleven freshly extracted blocks (2×1.5cm2) of human bone were prepared with a Er,Cr:YSGG laser by using a handheld handpiece, respectively, using the constructed device for a standardized cutting. A total of 44 cuts were executed. The specimen were then histologically evaluated. The standard test assembly met the requirements concerning the provision of objective results. The findings of the histological evaluation prove the reproducibility of the results. The standard test assembly presented in this paper facilitates comparative studies of different laser systems by reducing subjective influence on the preparation to a minimum. The results of this preliminary study show that the precision of the guiding instrument for laser cutting reduces the error of cut width by 50-fold, from 50to1μm.

  6. Guidelines for Serving At-Risk Students. A Publication to Assist School Districts in the Development of Local Plans Required by the Iowa Standard for At-Risk Students

    ERIC Educational Resources Information Center

    Iowa Department of Education, 2007

    2007-01-01

    This guide presents the Iowa standard for developing a plan to provide at risk students with the additional help they need to succeed. The standard requires a linkage of local, state, and federal resources within each local education agency. The guide is divided into five sections: (I) Introduction; (II) Provisions for At-Risk Students--The Iowa…

  7. 76 FR 38212 - Notice of Issuance of Regulatory Guide

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-29

    ... NUCLEAR REGULATORY COMMISSION [NRC-2010-0275] Notice of Issuance of Regulatory Guide AGENCY: Nuclear Regulatory Commission. ACTION: Notice of Issuance and Availability of Revision 1 of Regulatory Guide (RG) 1.179, ``Standard Format [[Page 38213

  8. Airline Transport Pilot, Aircraft Dispatcher, and Flight Navigator Knowledge Test Guide

    DOT National Transportation Integrated Search

    1995-01-01

    The Flight Standards Service of the Federal Aviation Administration (FAA) has developed this guide to help applicants meet the knowledge requirements for airline transport pilot, aircraft dispatcher, and flight navigator certification. This guide con...

  9. Spread Spectrum Receiver Electromagnetic Interference (EMI) Test Guide

    NASA Technical Reports Server (NTRS)

    Wheeler, M. L.

    1998-01-01

    The objective of this test guide is to document appropriate unit level test methods and techniques for the performance of EMI testing of Direct Sequence (DS) spread spectrum receivers. Consideration of EMI test methods tailored for spread spectrum receivers utilizing frequency spreading, techniques other than direct sequence (such as frequency hopping, frequency chirping, and various hybrid methods) is beyond the scope of this test guide development program and is not addressed as part of this document EMI test requirements for NASA programs are primarily developed based on the requirements contained in MIL-STD-46 1 D (or earlier revisions of MIL-STD-46 1). The corresponding test method guidelines for the MIL-STD-461 D tests are provided in MIL-STD-462D. These test methods are well documented with the exception of the receiver antenna port susceptibility tests (intermodulation, cross modulation, and rejection of undesired signals) which must be tailored to the specific type of receiver that is being tested. Thus, test methods addressed in this guide consist only of antenna port tests designed to evaluate receiver susceptibility characteristics. MIL-STD-462D should be referred for guidance pertaining to test methods for EMI tests other than the antenna port tests. The scope of this test guide includes: (1) a discussion of generic DS receiver performance characteristics; (2) a summary of S-band TDRSS receiver operation; (3) a discussion of DS receiver EMI susceptibility mechanisms and characteristics; (4) a summary of military standard test guidelines; (5) recommended test approach and methods; and (6) general conclusions and recommendations for future studies in the area of spread spectrum receiver testing.

  10. Science Standards: Making Them Work for You. Grades 3 and 4. Facilitor's Guide.

    ERIC Educational Resources Information Center

    Famellette, Judy

    This facilitator's guide, and the videotape it accompanies, is designed to demonstrate ways in which the new visions of science education for the 21st century might be translated into classroom practice. The National Research Council's (NRC) National Science Education Standards, American Association for the Advancement of Science (AAAS) Benchmarks…

  11. Standardized Curriculum for Small Engine Repair.

    ERIC Educational Resources Information Center

    Mississippi State Dept. of Education, Jackson. Office of Vocational, Technical and Adult Education.

    This curriculum guide for small engine repair was developed by the state of Mississippi to standardize vocational education course titles and core contents. The objectives contained in this document are common to all small engine repair programs in the state. The guide contains objectives for small engine repair I and II courses. Units in course I…

  12. Teaching the African-American Experience in the Palmetto State. Educator Resource Guide.

    ERIC Educational Resources Information Center

    South Carolina State Dept. of Education, Columbia.

    This resource guide for teaching the African-American experience in South Carolina's public schools is designed to serve as a supplement to the "South Carolina Social Studies Curriculum Standards." Focusing on the history and culture of Africa and African-Americans within the specific context of the state's curriculum standards and…

  13. Music--A Resource Guide for Standards-Based Instruction.

    ERIC Educational Resources Information Center

    New York State Education Dept., Albany.

    This guide is designed to provide guidance to New York state school districts and teachers to help students achieve the music standards. Teachers throughout New York state met to compile these field-tested lesson plans, teaching strategies, assessments, and resources for teachers of students in pre-kindergarten through grade 12, in all areas of…

  14. Emergency Medical Technician-Ambulance: National Standard Curriculum. Student Study Guide (Third Edition).

    ERIC Educational Resources Information Center

    National Highway Traffic Safety Administration (DOT), Washington, DC.

    This student study guide is one of three documents prepared for the Emergency Medical Technician (EMT), National Standard Curriculum. The course is designed to develop skills in symptom recognition and in all emergency care procedures and techniques currently considered to be within the responsibilities of an EMT providing emergency medical care…

  15. Computed tomography guided localization of clinically occult breast carcinoma-the ''N'' skin guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kopans, D.B.; Meyer, J.E.

    1982-10-01

    Standard computed tomography (CT) can be used for the three-dimensional localization of clinically occult suspicious breast lesions whose exact position cannot be determined by standard mammographic views. A method is described that facilitates accurate preoperative needle localization using CT guidance, once the position of these lesions is defined.

  16. Standardized Curriculum for Metal Trades.

    ERIC Educational Resources Information Center

    Mississippi State Dept. of Education, Jackson. Office of Vocational, Technical and Adult Education.

    This curriculum guide for the metal trades was developed by the state of Mississippi to standardize vocational education course titles and core contents. The objectives contained in this document are common to all metal trades programs in the state. The guide contains objectives for Metal Trades I and II courses. Units in Metal Trades I cover the…

  17. Mid-Management Guide for Post Secondary Marketing and Distributive Education. AVTS and Community College.

    ERIC Educational Resources Information Center

    Emporia State Univ., KS.

    This curriculum guide is intended to aid community colleges, area vocational technical schools, and other institutions that provide mid-management educational programs in the state of Kansas to eliminate duplication between various institutions and to provide standard titles and standard content from institution to institution. Following an…

  18. Shielded Metal Arc Pipe Welding. Teacher Edition. Second Edition.

    ERIC Educational Resources Information Center

    Fortney, Clarence; And Others

    This second edition of the shielded metal arc pipe welding curriculum guide presents both basic and advanced pipe welding skills. All specifications for procedure and welder qualification are presented according to national standards. The standards also include the test position for both groove and fillet pipe welding. The guide contains three…

  19. Making It Happen: Common Core Standards

    ERIC Educational Resources Information Center

    National Council of Teachers of Mathematics, 2011

    2011-01-01

    This one-of-a-kind guide identifies and highlights the ways in which NCTM (National Council of Teachers of Mathematics) resources can support teachers as they implement and supplement the Common Core State Standards for Mathematics (CCSSM) in their states. The guide and accompanying charts are tools to help educators as they continue to make…

  20. An Overview of the Guided Parafoil System Derived from X-38 Experience

    NASA Technical Reports Server (NTRS)

    Stein, Jenny M.; Madsen, Chris M.; Strahan, Alan L.

    2005-01-01

    The NASA Johnson Space Center built a 4200 sq ft parafoil for the U.S. Army Natick Soldier Center to demonstrate autonomous flight using a guided parafoil system to deliver 10,000 lbs of useable payload. The parafoil's design was based upon that developed during the X-38 program. The drop test payload consisted of a standard 20-foot Type V airdrop platform, a standard 12-foot weight tub, a 60 ft drogue parachute, a 4200 ft2 parafoil, an instrumentation system, and a Guidance, Navigation, and Control (GN&C) system. Instrumentation installed on the load was used to gather data to validate simulation models and preflight loads predictions and to perform post flight trajectory and performance reconstructions. The GN&C system, developed during NASA's X-38 program, consisted of a flight computer, modems for uplink commands and downlink data, a compass, laser altimeter, and two winches. The winches were used to steer the parafoil and to perform the dynamic flare maneuver for a soft landing. The laser was used to initiate the flare. The GN&C software was originally provided to NASA by the European Space Agency. NASA incorporated further software refinements based upon the X-38 flight test results. Three full-scale drop tests were conducted, with the third being performed during the Precision Airdrop Technology Conference and Demonstration (PATCAD) Conference at the U.S. Army Yuma Proving Ground (YPG) in November of 2003. For the PATCAD demonstration, the parafoil and GN&C software and hardware performed well, concluding with a good flare and the smallest miss distance ever experienced in NASA's parafoil drop test program. This paper describes the 4200 sq ft parafoil system, simulation results, and the results of the drop tests.

  1. Fluoroscopy-Guided Pull-Through Gastrostomy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pitton, M. B., E-mail: pitton@radiologie.klinik.uni-mainz.de; Herber, S.; Dueber, C.

    2008-01-15

    The purpose of this study was to simplify a fluoroscopy guided gastrostomy technique using pull-type tubes which are traditionally introduced with gastroscopic assistance. The stomach was transorally probed with a 5-Fr catheter and a guidewire. A second access was performed percutaneously through the anterior abdominal and gastric wall using an 8-Fr sheath and an 8-Fr guiding catheter. A duplicated guidewire was introduced through the guiding catheter in order to result in a great custom-made loop within the stomach. The transoral guidewire was captured and tightened with this loop and the guiding catheter, and both were subsequently pulled by the transoralmore » guidewire until the tip of the guiding catheter exited the mouth. A thread was fed through the guiding catheter for fixation of the pull-type gastrostomy tube. Finally, the fixed tube was pulled through the esophagus into the stomach and through the abdominal wall until the anterior gastric wall fixed the retention plate of the tube. Thirty-seven patients (28 male, 9 female; age, 65.1 {+-} 14.4 years) with miscellaneous indications for percutaneous gastrostomies were supplied with pull-type gastrostomy catheters in a fluoroscopy technique without endoscopic assistance. Twenty-five of the 37 patients (67.6%) had undergone unsuccessful preceding gastroscopically guided PEG attempts because of tumor stenosis (n = 12) or impossible transillumination of the abdominal wall (n = 13). All procedures were technically successful, without major complications. Particularly, all patients with frustrating gastroscopic attempts were successfully provided with pull-type gastrostomy tubes. Five minor complications occurred: one tube loss during the passage of the hypopoharynx because of a torn thread, one transient small leakage alongside the tube (both successfully treated), and three cases of transient moderate local pain without leakage (symptomatic treatment). We conclude that this fluoroscopy-guided pull-through gastrostomy technique is easy and safe to perform and may be suggested as a standard procedure for radiological gastrostomies. It combines the ease of the radiological approach with the advantages of the pull-type tube devices, particularly the benefits of the typical retention plates.« less

  2. The Long Range Reconnaissance and Observation System (LORROS) with the Kollsman, Inc. Model LH-40, Infrared (Erbium) Laser Rangefinder hazard analysis and safety assessment.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Augustoni, Arnold L.

    A laser hazard analysis and safety assessment was performed for the LH-40 IR Laser Rangefinder based on the 2000 version of the American National Standard Institute's Standard Z136.1, for the Safe Use of Lasers and Z136.6, for the Safe Use of Lasers Outdoors. The LH-40 IR Laser is central to the Long Range Reconnaissance and Observation System (LORROS). The LORROS is being evaluated by the Department 4149 Group to determine its capability as a long-range assessment tool. The manufacture lists the laser rangefinder as 'eye safe' (Class 1 laser classified under the CDRH Compliance Guide for Laser Products and 21more » CFR 1040 Laser Product Performance Standard). It was necessary that SNL validate this prior to its use involving the general public. A formal laser hazard analysis is presented for the typical mode of operation.« less

  3. Aztec Ruins National Monument. Teacher's Guide, Grades 4-7.

    ERIC Educational Resources Information Center

    Nichols, Theresa, Comp.

    This teacher's guide is for educators in classrooms, outdoor education, youth groups, scouting, and after-school programs to teach about the Aztec Ruins National Monument (New Mexico). The teaching materials in the guide support the New Mexico educational standards in science, social studies, language arts, mathematics, and art. Since the guide's…

  4. Economics. Teacher's Guide [and Student Guide]. Parallel Alternative Strategies for Students (PASS).

    ERIC Educational Resources Information Center

    Chambliss, Robert, Ed.; Fresen, Sue, Ed.

    This teacher's guide and student guide unit contains supplemental readings, activities, and methods adapted for secondary students who have disabilities and other students with diverse learning needs. The curriculum correlates to Florida's Sunshine State Standards and is divided into the following six units of study: (1) introduction to economics,…

  5. World History--Part 2: Teacher's Guide [and Student Guide]. Parallel Alternative Strategies for Students (PASS).

    ERIC Educational Resources Information Center

    Schaap, Eileen, Ed.; Fresen, Sue, Ed.

    This teacher's guide and student guide unit contains supplemental readings, activities, and methods adapted for secondary students who have disabilities and other students with diverse learning needs. The materials differ from standard textbooks and workbooks in several ways: simplified text; smaller units of study; reduced vocabulary level;…

  6. Career Orientation. Arkansas Public School Course Content Guide.

    ERIC Educational Resources Information Center

    Arkansas State Dept. of Education, Little Rock.

    This course content guide was developed in accordance with the Standards for Accreditation of Public Schools adopted by the Arkansas State Board of Education. The guide is offered as a framework upon which a curriculum can be built. The content guide identifies skills at three instructional levels: basic, developmental, and extensions. The basic…

  7. Home Economics. Arkansas Public School Course Content Guide.

    ERIC Educational Resources Information Center

    Arkansas State Dept. of Education, Little Rock.

    This course content guide was developed in accordance with the Standards for Accreditation of Public Schools adopted by the Arkansas State Board of Education. The guide is offered as a framework upon which a curriculum can be built. Within each subject area, the content guide identifies skills at three instructional levels: basic, developmental,…

  8. Health Occupations. Arkansas Public School Course Content Guide.

    ERIC Educational Resources Information Center

    Arkansas State Dept. of Education, Little Rock.

    This course content guide was developed in accordance with the Standards for Accreditation of Public Schools adopted by the Arkansas State Board of Education. The guide is offered as a framework upon which a curriculum can be built. Within each subject area the content guide identifies skills at three instructional levels: basic, developmental,…

  9. Update to a guide to standardized highway lighting pole hardware.

    DOT National Transportation Integrated Search

    2013-03-01

    This report describes the development of an updated Online Guide to Luminaire Supports. The Guide is a web-based content : management system for luminaire support systems that allows full viewing, submission, management, and reporting services : to i...

  10. Evaluation of reliability and validity of three dental color-matching devices.

    PubMed

    Tsiliagkou, Aikaterini; Diamantopoulou, Sofia; Papazoglou, Efstratios; Kakaboura, Afrodite

    2016-01-01

    To assess the repeatability and accuracy of three dental color-matching devices under standardized and freehand measurement conditions. Two shade guides (Vita Classical A1-D4, Vita; and Vita Toothguide 3D-Master, Vita), and three color-matching devices (Easyshade, Vita; SpectroShade, MHT Optic Research; and ShadeVision, X-Rite) were used. Five shade tabs were selected from the Vita Classical A1-D4 (A2, A3.5, B1, C4, D3), and five from the Vita Toothguide 3D-Master (1M1, 2R1.5, 3M2, 4L2.5, 5M3) shade guides. Each shade tab was recorded 15 continuous, repeated times with each device under two different measurement conditions (standardized, and freehand). Both qualitative (color shade) and quantitative (L, a, and b) color characteristics were recorded. The color difference (ΔE) of each recorded value with the known values of the shade tab was calculated. The repeatability of each device was evaluated by the coefficient of variance. The accuracy of each device was determined by comparing the recorded values with the known values of the reference shade tab (one sample t test; α = 0.05). The agreement between the recorded shade and the reference shade tab was calculated. The influence of the parameters (devices and conditions) on the parameter ΔE was investigated (two-way ANOVA). Comparison of the devices was performed with Bonferroni pairwise post-hoc analysis. Under standardized conditions, repeatability of all three devices was very good, except for ShadeVision with Vita Classical A1-D4. Accuracy ranged from good to fair, depending on the device and the shade guide. Under freehand conditions, repeatability and accuracy for Easyshade and ShadeVision were negatively influenced, but not for SpectroShade, regardless of the shade guide. Based on the total of the color parameters assessed per device, SpectroShade was the most reliable of the three color-matching devices studied.

  11. ASCCP Colposcopy Standards: How Do We Perform Colposcopy? Implications for Establishing Standards.

    PubMed

    Waxman, Alan G; Conageski, Christine; Silver, Michelle I; Tedeschi, Candice; Stier, Elizabeth A; Apgar, Barbara; Huh, Warner K; Wentzensen, Nicolas; Massad, L Stewart; Khan, Michelle J; Mayeaux, Edward J; Einstein, Mark H; Schiffman, Mark H; Guido, Richard S

    2017-10-01

    The American Society for Colposcopy and Cervical Pathology (ASCCP) Colposcopy Standards recommendations address the role of and approach to colposcopy and biopsy for cervical cancer prevention in the United States. The recommendations were developed by an expert working group appointed by ASCCP's Board of Directors. Working group 3 defined colposcopy procedure guidelines for minimum and comprehensive colposcopy practice and evaluated the use of colposcopy adjuncts. The working group performed a systematic literature review to identify best practices in colposcopy methodology and to evaluate the use of available colposcopy adjuncts. The literature provided little evidence to support specific elements of the procedure. The working group, therefore, implemented a national survey of current and recent ASCCP members to evaluate common elements of the colposcopy examination. The findings of this survey were modified by expert consensus from the ASCCP Colposcopy Standards Committee members to create guidelines for performing colposcopy. The draft recommendations were posted online for public comment and presented at an open session of the International Federation for Cervical Pathology and Colposcopy 2017 World Congress for further comment. All comments were considered in the development of final recommendations. Minimum and comprehensive colposcopy practice guidelines were developed. These guidelines represent recommended practice in all parts of the examination including the following: precolposcopy evaluation, performing the procedure, documentation of findings, biopsy practice, and postprocedure follow-up. These guidelines are intended to serve as a guide to standardize colposcopy across the United States.

  12. Incipient Crack Detection in Composite Wind Turbine Blades

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, Stuart G.; Choi, Mijin; Jeong, Hyomi

    2012-08-28

    This paper presents some analysis results for incipient crack detection in a 9-meter CX-100 wind turbine blade that underwent fatigue loading to failure. The blade was manufactured to standard specifications, and it underwent harmonic excitation at its first resonance using a hydraulically-actuated excitation system until reaching catastrophic failure. This work investigates the ability of an ultrasonic guided wave approach to detect incipient damage prior to the surfacing of a visible, catastrophic crack. The blade was instrumented with piezoelectric transducers, which were used in an active, pitchcatch mode with guided waves over a range of excitation frequencies. The performance results inmore » detecting incipient crack formation in the fiberglass skin of the blade is assessed over the range of frequencies in order to determine the point at which the incipient crack became detectable. Higher excitation frequencies provide consistent results for paths along the rotor blade's carbon fiber spar cap, but performance falls off with increasing excitation frequencies for paths off of the spar cap. Lower excitation frequencies provide more consistent performance across all sensor paths.« less

  13. Perk Station – Percutaneous Surgery Training and Performance Measurement Platform

    PubMed Central

    Vikal, Siddharth; U-Thainual, Paweena; Carrino, John A.; Iordachita, Iulian; Fischer, Gregory S.; Fichtinger, Gabor

    2009-01-01

    Motivation Image-guided percutaneous (through the skin) needle-based surgery has become part of routine clinical practice in performing procedures such as biopsies, injections and therapeutic implants. A novice physician typically performs needle interventions under the supervision of a senior physician; a slow and inherently subjective training process that lacks objective, quantitative assessment of the surgical skill and performance[S1]. Shortening the learning curve and increasing procedural consistency are important factors in assuring high-quality medical care. Methods This paper describes a laboratory validation system, called Perk Station, for standardized training and performance measurement under different assistance techniques for needle-based surgical guidance systems. The initial goal of the Perk Station is to assess and compare different techniques: 2D image overlay, biplane laser guide, laser protractor and conventional freehand. The main focus of this manuscript is the planning and guidance software system developed on the 3D Slicer platform, a free, open source software package designed for visualization and analysis of medical image data. Results The prototype Perk Station has been successfully developed, the associated needle insertion phantoms were built, and the graphical user interface was fully implemented. The system was inaugurated in undergraduate teaching and a wide array of outreach activities. Initial results, experiences, ongoing activities and future plans are reported. PMID:19539446

  14. Improving HIV outcomes in resource-limited countries: the importance of quality indicators.

    PubMed

    Ahonkhai, Aima A; Bassett, Ingrid V; Ferris, Timothy G; Freedberg, Kenneth A

    2012-11-24

    Resource-limited countries increasingly depend on quality indicators to improve outcomes within HIV treatment programs, but indicators of program performance suitable for use at the local program level remain underdeveloped. Using the existing literature as a guide, we applied standard quality improvement (QI) concepts to the continuum of HIV care from HIV diagnosis, to enrollment and retention in care, and highlighted critical service delivery process steps to identify opportunities for performance indicator development. We then identified existing indicators to measure program performance, citing examples used by pivotal donor agencies, and assessed their feasibility for use in surveying local program performance. Clinical delivery steps without existing performance measures were identified as opportunities for measure development. Using National Quality Forum (NQF) criteria as a guide, we developed measurement concepts suitable for use at the local program level that address existing gaps in program performance assessment. This analysis of the HIV continuum of care identified seven critical process steps providing numerous opportunities for performance measurement. Analysis of care delivery process steps and the application of NQF criteria identified 24 new measure concepts that are potentially useful for improving operational performance in HIV care at the local level. An evidence-based set of program-level quality indicators is critical for the improvement of HIV care in resource-limited settings. These performance indicators should be utilized as treatment programs continue to grow.

  15. Design guide for low cost standardized payloads, volume 2

    NASA Technical Reports Server (NTRS)

    1972-01-01

    Sixteen engineering approaches to low cost standardized payloads in spacecraft are presented. Standard earth observatory satellite, standard U.S. domestic communication satellite, planetary spacecraft subsystems, standard spacecraft, and cluster spacecraft are reviewed.

  16. Doppler Endoscopic Probe Monitoring of Blood Flow Improves Risk Stratification and Outcomes of Patients With Severe Nonvariceal Upper Gastrointestinal Hemorrhage.

    PubMed

    Jensen, Dennis M; Kovacs, Thomas O G; Ohning, Gordon V; Ghassemi, Kevin; Machicado, Gustavo A; Dulai, Gareth S; Sedarat, Alireza; Jutabha, Rome; Gornbein, Jeffrey

    2017-05-01

    For 4 decades, stigmata of recent hemorrhage in patients with nonvariceal lesions have been used for risk stratification and endoscopic hemostasis. The arterial blood flow that underlies the stigmata rarely is monitored, but can be used to determine risk for rebleeding. We performed a randomized controlled trial to determine whether Doppler endoscopic probe monitoring of blood flow improves risk stratification and outcomes in patients with severe nonvariceal upper gastrointestinal hemorrhage. In a single-blind study performed at 2 referral centers we assigned 148 patients with severe nonvariceal upper gastrointestinal bleeding (125 with ulcers, 19 with Dieulafoy's lesions, and 4 with Mallory Weiss tears) to groups that underwent standard, visually guided endoscopic hemostasis (control, n = 76), or endoscopic hemostasis assisted by Doppler monitoring of blood flow under the stigmata (n = 72). The primary outcome was the rate of rebleeding after 30 days; secondary outcomes were complications, death, and need for transfusions, surgery, or angiography. There was a significant difference in the rates of lesion rebleeding within 30 days of endoscopic hemostasis in the control group (26.3%) vs the Doppler group (11.1%) (P = .0214). The odds ratio for rebleeding with Doppler monitoring was 0.35 (95% confidence interval, 0.143-0.8565) and the number needed to treat was 7. In a randomized controlled trial of patients with severe upper gastrointestinal hemorrhage from ulcers or other lesions, Doppler probe guided endoscopic hemostasis significantly reduced 30-day rates of rebleeding compared with standard, visually guided hemostasis. Guidelines for nonvariceal gastrointestinal bleeding should incorporate these results. ClinicalTrials.gov no: NCT00732212 (CLIN-013-07F). Copyright © 2017 AGA Institute. Published by Elsevier Inc. All rights reserved.

  17. 78 FR 73566 - Standard Format and Content for a License Application for an Independent Spent Fuel Storage...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-06

    ...The U.S. Nuclear Regulatory Commission (NRC) is issuing for public comment draft regulatory guide (DG), DG-3042, ``Standard Format and Content for a License Application for an Independent Spent Fuel Storage Installation or a Monitored Retrievable Storage Facility.'' This draft regulatory guide is proposed revision 2 of Regulatory Guide 3.50, which provides a format that the NRC considers acceptable for submitting the information for license applications to store spent nuclear fuel, high-level radioactive waste, and/or reactor-related Greater than Class C waste.

  18. Endoscopic treatment for pancreatic diseases: Needle-knife-guided cannulation via the minor papilla

    PubMed Central

    Wang, Wei; Gong, Biao; Jiang, Wei-Song; Liu, Lei; Bielike, Kouken; Xv, Bin; Wu, Yun-Lin

    2015-01-01

    AIM: To determine the efficacy and safety of meticulous cannulation by needle-knife. METHODS: Three needle-knife procedures were used to facilitate cannulation in cases when standard cannulation techniques failed. A total of 104 cannulations via the minor papilla attempted in 74 patients at our center between January 2008 and June 2014 were retrospectively reviewed. RESULTS: Standard methods were successful in 79 cannulations. Of the 25 cannulations that could not be performed by standard methods, 19 were performed by needle-knife, while 17 (89.5%) were successful. Needle-knife use improved the success rate of cannulation [76.0%, 79/104 vs 92.3%, (79 + 17)/104; P = 0.001]. When the 6 cases not appropriate for needle-knife cannulation were excluded, the success rate was improved further (80.6%, 79/98 vs 98.0%, 96/98; P = 0.000). There were no significant differences in the rates of post-endoscopic retrograde cholangiopancreatography adverse events between the group using standard methods alone and the group using needle-knife after failure of standard methods (4.7% vs 10.5%, P = 0.301). CONCLUSION: The needle-knife procedure may be an alternative method for improving the success rate of cannulation via the minor papilla, particularly when standard cannulation has failed. PMID:26019460

  19. Endoscopic treatment for pancreatic diseases: Needle-knife-guided cannulation via the minor papilla.

    PubMed

    Wang, Wei; Gong, Biao; Jiang, Wei-Song; Liu, Lei; Bielike, Kouken; Xv, Bin; Wu, Yun-Lin

    2015-05-21

    To determine the efficacy and safety of meticulous cannulation by needle-knife. Three needle-knife procedures were used to facilitate cannulation in cases when standard cannulation techniques failed. A total of 104 cannulations via the minor papilla attempted in 74 patients at our center between January 2008 and June 2014 were retrospectively reviewed. Standard methods were successful in 79 cannulations. Of the 25 cannulations that could not be performed by standard methods, 19 were performed by needle-knife, while 17 (89.5%) were successful. Needle-knife use improved the success rate of cannulation [76.0%, 79/104 vs 92.3%, (79 + 17)/104; P = 0.001]. When the 6 cases not appropriate for needle-knife cannulation were excluded, the success rate was improved further (80.6%, 79/98 vs 98.0%, 96/98; P = 0.000). There were no significant differences in the rates of post-endoscopic retrograde cholangiopancreatography adverse events between the group using standard methods alone and the group using needle-knife after failure of standard methods (4.7% vs 10.5%, P = 0.301). The needle-knife procedure may be an alternative method for improving the success rate of cannulation via the minor papilla, particularly when standard cannulation has failed.

  20. A Guide for Developing Standard Operating Job Procedures for the Primary Sedimentation Process Wastewater Treatment Facility. SOJP No. 4.

    ERIC Educational Resources Information Center

    Charles County Community Coll., La Plata, MD.

    This guide describes standard operating job procedures for the primary sedimentation process of wastewater treatment plants. The primary sedimentation process involves removing settleable and suspended solids, in part, from wastewater by gravitational forces, and scum and other floatable solids from wastewater by mechanical means. Step-by-step…

  1. Standards of Learning Objectives for Virginia Public Schools: Theatre Arts, Oral Communication, Journalism.

    ERIC Educational Resources Information Center

    Virginia State Dept. of Education, Richmond.

    The Standards of Learning Objectives for Virginia Public Schools in the areas of theatre arts, oral communication, and journalism explicitly stated in this guide reflect the scope and depth of these elective subjects and identify some appropriate ends for instruction. The guide outlines the program goals, objectives, guidelines, and SOL objectives…

  2. Guidelines and Standards for Proprietary Schools.

    ERIC Educational Resources Information Center

    Georgia State Dept. of Education, Atlanta. Office of Planning and Development.

    This guide contains information pertaining to the law, rules, regulations, and standards of practice that apply to proprietary schools operating in Georgia, as provided in the Georgia Proprietary School Act (O.C.G.A. Section 20-4-60 and following, Georgia School Laws). The guide has been adopted by the Georgia Board of Education and is used in the…

  3. Living Traditions--A Teacher's Guide: Teaching Local History Using State and National Learning Standards.

    ERIC Educational Resources Information Center

    Skelding, Mark; Kemple, Martin; Kiefer, Joseph

    This guide is designed to take teachers through a step-by-step process for developing an integrated, standards-based curriculum that focuses on the stories, history, folkways, and agrarian traditions of the local community. Such a place-based curriculum helps students to become culturally literate, makes learning relevant and engaging, draws on…

  4. XML Style Guide

    DTIC Science & Technology

    2015-07-01

    Acronyms ASCII American Standard Code for Information Interchange DAU data acquisition unit DDML data display markup language IHAL...Transfer Standard URI uniform resource identifier W3C World Wide Web Consortium XML extensible markup language XSD XML schema definition XML Style...Style Guide, RCC 125-15, July 2015 1 Introduction The next generation of telemetry systems will rely heavily on extensible markup language (XML

  5. Applying NCTE/IRA Standards in Classroom Journalism Projects: Activities and Scenarios.

    ERIC Educational Resources Information Center

    Bowen, Candace Perkins; Tantillo, Susan Hathaway

    Whether an educator teaches journalism, English, or language arts, this guide will help him/her help middle school and high school students get the most from journalism study and practice informed by English language arts standards. The guide is organized into 12 chapters, each focusing on how the kinds of student journalism work advocated by the…

  6. An overview of the National Space Science data Center Standard Information Retrieval System (SIRS)

    NASA Technical Reports Server (NTRS)

    Shapiro, A.; Blecher, S.; Verson, E. E.; King, M. L. (Editor)

    1974-01-01

    A general overview is given of the National Space Science Data Center (NSSDC) Standard Information Retrieval System. A description, in general terms, the information system that contains the data files and the software system that processes and manipulates the files maintained at the Data Center. Emphasis is placed on providing users with an overview of the capabilities and uses of the NSSDC Standard Information Retrieval System (SIRS). Examples given are taken from the files at the Data Center. Detailed information about NSSDC data files is documented in a set of File Users Guides, with one user's guide prepared for each file processed by SIRS. Detailed information about SIRS is presented in the SIRS Users Guide.

  7. CT-guided infiltration saves surgical intervention and fastens return to work compared to anatomical landmark-guided infiltration in patients with lumbosciatica.

    PubMed

    Deml, Moritz C; Buhr, Michael; Wimmer, Matthias D; Pflugmacher, Robert; Riedel, Rainer; Rommelspacher, Yorck; Kabir, Koroush

    2015-07-01

    Infiltration procedures are a common treatment of lumbar radiculopathy. There is a wide variety of infiltration techniques without an established gold standard. Therefore, we compared the effectiveness of CT-guided transforaminal infiltrations versus anatomical landmark-guided transforaminal infiltrations at the lower lumbar spine in case of acute sciatica at L3-L5. A retrospective chart review was conducted of 107 outpatients treated between 2009 and 2011. All patients were diagnosed with lumbar radiculopathic pain secondary to disc herniation in L3-L5. A total of 52 patients received CT-guided transforaminal infiltrations; 55 patients received non-imaging-guided nerve root infiltrations. The therapeutic success was evaluated regarding number of physician contacts, duration of treatment, type of analgesics used and loss of work days. Defined endpoint was surgery at the lower lumbar spine. In the CT group, patients needed significantly less oral analgesics (p < 0.001). Overall treatment duration and physician contacts were significantly lower in the CT group (p < 0.001 and 0.002) either. In the CT group, patients lost significant fewer work days due to incapacity (p < 0.001). Surgery had to be performed in 18.2 % of the non-imaging group patients (CT group: 1.9 %; p = 0.008). This study shows that CT-guided periradicular infiltration in lumbosciatica caused by intervertebral disc herniation is significantly superior to non-imaging, anatomical landmark-guided infiltration, regarding the parameters investigated. The high number of treatment failures in the non-imaging group underlines the inferiority of this treatment concept.

  8. [An illustrated guide to dental screening: a school survey].

    PubMed

    Tenenbaum, Annabelle; Sayada, Mélanie; Azogui-Levy, Sylvie

    2017-12-05

    Marked social inequalities in oral health are observed right from early childhood. A mandatory complete health check-up, including dental screening, is organized at school for 6-year-old children. School healthcare professionals are not well trained in dental health. The aim of this study was to assess the relevance of an illustrated guide as a simple and rapid dental screening training tool in order to ensure effective, standardized and reproducible screening. A cross-sectional study was conducted in the context of the dental examination performed as part of the health check-up. Two examiners (Doctor E1 and Nurse E2) were trained in dental screening by means of the illustrated guide. This reference guide, comprising pictures and legends, presents the main oral pathology observed in children. 109 consent forms for oral screening were delivered, and 102 children agreed to participate (93.57%). The sensitivity of detection of tooth decay by examiners E1 and E2 was 81.48% with a specificity of 96%. No correlation was observed between the child's age (+/- 6 years) and correct detection rates. The illustrated guide is an appropriate and rapid tool for dental screening that can improve the quality of dental check-up and increase the number of children detected.

  9. Evaluation of degree of conversion and hardness of dental composites photo-activated with different light guide tips.

    PubMed

    Galvão, Marília Regalado; Caldas, Sergei Godeiro Fernandes Rabelo; Bagnato, Vanderlei Salvador; de Souza Rastelli, Alessandra Nara; de Andrade, Marcelo Ferrarezi

    2013-01-01

    The aim of this study was to evaluate the degree of conversion and hardness of different composite resins, photo-activated for 40 s with two different light guide tips, fiber optic and polymer. Five specimens were made for each group evaluated. The percentage of unreacted carbon double bonds (% C═C) was determined from the ratio of absorbance intensities of aliphatic C═C (peak at 1637 cm(-1)) against internal standard before and after curing of the specimen: aromatic C-C (peak at 1610 cm(-1)). The Vickers hardness measurements were performed in a universal testing machine. A 50 gf load was used and the indenter with a dwell time of 30 seconds. The degree of conversion and hardness mean values were analyzed separately by ANOVA and Tukey's test, with a significance level set at 5%. The mean values of degree of conversion for the polymer and fiber optic light guide tip were statistically different (P<.001). The hardness mean values were statistically different among the light guide tips (P<.001), but also there was difference between top and bottom surfaces (P<.001). The results showed that the resins photo-activated with the fiber optic light guide tip promoted higher values for degree of conversion and hardness.

  10. Evaluation of degree of conversion and hardness of dental composites photo-activated with different light guide tips

    PubMed Central

    Galvão, Marília Regalado; Caldas, Sergei Godeiro Fernandes Rabelo; Bagnato, Vanderlei Salvador; de Souza Rastelli, Alessandra Nara; de Andrade, Marcelo Ferrarezi

    2013-01-01

    Objective: The aim of this study was to evaluate the degree of conversion and hardness of different composite resins, photo-activated for 40 s with two different light guide tips, fiber optic and polymer. Methods: Five specimens were made for each group evaluated. The percentage of unreacted carbon double bonds (% C═C) was determined from the ratio of absorbance intensities of aliphatic C═C (peak at 1637 cm−1) against internal standard before and after curing of the specimen: aromatic C-C (peak at 1610 cm−1). The Vickers hardness measurements were performed in a universal testing machine. A 50 gf load was used and the indenter with a dwell time of 30 seconds. The degree of conversion and hardness mean values were analyzed separately by ANOVA and Tukey’s test, with a significance level set at 5%. Results: The mean values of degree of conversion for the polymer and fiber optic light guide tip were statistically different (P<.001). The hardness mean values were statistically different among the light guide tips (P<.001), but also there was difference between top and bottom surfaces (P<.001). Conclusions: The results showed that the resins photo-activated with the fiber optic light guide tip promoted higher values for degree of conversion and hardness. PMID:23407620

  11. Automated tru-cut imaging-guided core needle biopsy of canine orbital neoplasia. A prospective feasibility study

    PubMed Central

    Cirla, A.; Rondena, M.; Bertolini, G.

    2016-01-01

    The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single centre. A complete ophthalmic examination was always followed by orbital ultrasound and computed tomography (CT) examination of the head. All masses were sampled with the patient still on the CT table using ultrasound (US) guided automatic tru-cut device. The most suitable sampling approach to the orbit was chosen each time based on the CT image analysis. One of the following different approaches was used: trans-orbital, trans-conjunctival or trans-masseteric. In all cases, the imaging-guided biopsy provided a sufficient amount of tissue for the histopathological diagnosis, which concurred with the biopsies obtained using the excisional technique. CT examination was essential for morphological diagnosis and provided detailed topographic information that allowed us to choose the safest orbital approach for the biopsy. US guided automatic tru-cut biopsy based on CT images, performed with patient still on the CT table, resulted in a minimally invasive, relatively easy, and accurate diagnostic procedure in dogs with orbital masses. PMID:27540512

  12. Automated tru-cut imaging-guided core needle biopsy of canine orbital neoplasia. A prospective feasibility study.

    PubMed

    Cirla, A; Rondena, M; Bertolini, G

    2016-01-01

    The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single centre. A complete ophthalmic examination was always followed by orbital ultrasound and computed tomography (CT) examination of the head. All masses were sampled with the patient still on the CT table using ultrasound (US) guided automatic tru-cut device. The most suitable sampling approach to the orbit was chosen each time based on the CT image analysis. One of the following different approaches was used: trans-orbital, trans-conjunctival or trans-masseteric. In all cases, the imaging-guided biopsy provided a sufficient amount of tissue for the histopathological diagnosis, which concurred with the biopsies obtained using the excisional technique. CT examination was essential for morphological diagnosis and provided detailed topographic information that allowed us to choose the safest orbital approach for the biopsy. US guided automatic tru-cut biopsy based on CT images, performed with patient still on the CT table, resulted in a minimally invasive, relatively easy, and accurate diagnostic procedure in dogs with orbital masses.

  13. Adherence to Standards for Reporting Diagnostic Accuracy in Emergency Medicine Research.

    PubMed

    Gallo, Lucas; Hua, Nadia; Mercuri, Mathew; Silveira, Angela; Worster, Andrew

    2017-08-01

    Diagnostic tests are used frequently in the emergency department (ED) to guide clinical decision making and, hence, influence clinical outcomes. The Standards for Reporting of Diagnostic Accuracy (STARD) criteria were developed to ensure that diagnostic test studies are performed and reported to best inform clinical decision making in the ED. The objective was to determine the extent to which diagnostic studies published in emergency medicine journals adhered to STARD 2003 criteria. Diagnostic studies published in eight MEDLINE-listed, peer-reviewed, emergency medicine journals over a 5-year period were reviewed for compliance to STARD criteria. A total of 12,649 articles were screened and 114 studies were included in our study. Twenty percent of these were randomly selected for assessment using STARD 2003 criteria. Adherence to STARD 2003 reporting standards for each criteria ranged from 8.7% adherence (criteria-reporting adverse events from performing index test or reference standard) to 100% (multiple criteria). Just over half of STARD criteria are reported in more than 80% studies. As poorly reported studies may negatively impact their clinical usefulness, it is essential that studies of diagnostic test accuracy be performed and reported adequately. Future studies should assess whether studies have improved compliance with the STARD 2015 criteria amendment. © 2017 by the Society for Academic Emergency Medicine.

  14. World History--Part 1. Teacher's Guide [and Student Guide]. Parallel Alternative Strategies for Students (PASS).

    ERIC Educational Resources Information Center

    Schaap, Eileen, Ed.; Fresen, Sue, Ed.

    This teacher's guide and student guide unit contains supplemental readings, activities, and methods adapted for secondary students who have disabilities and other students with diverse learning needs. The unit focuses on world history and correlates to Florida's Sunshine State Standards. It is divided into the following 21 units of study that…

  15. Business Ownership and Management. Arkansas Public School Course Content Guide.

    ERIC Educational Resources Information Center

    Arkansas State Dept. of Education, Little Rock.

    This course content guide was developed in accordance with the Standards for Accreditation of Public Schools adopted by the Arkansas State Board of Education. The guide is offered as a framework upon which a curriculum can be built. Within the subject area and at each grade level, the content guide identifies skills at three instructional levels:…

  16. Exploratory Coordinated Career Education. Arkansas Public School Course Content Guide.

    ERIC Educational Resources Information Center

    Arkansas State Dept. of Education, Little Rock.

    This course content guide was developed in accordance with the Standards for Accreditation of Public Schools adopted by the Arkansas State Board of Education. The guide is offered as a framework upon which a curriculum can be built. Within the subject area and at each grade level, the content guide identifies skills at three instructional levels:…

  17. Junior High Business Education. Arkansas Public School Course Content Guide.

    ERIC Educational Resources Information Center

    Arkansas State Dept. of Education, Little Rock.

    This course content guide was developed in accordance with the Standards for Accreditation of Public Schools adopted by the Arkansas State Board of Education. The guide is offered as a framework upon which a curriculum can be built. Within the subject area and at each grade level, the content guide identifies skills at three instructional levels:…

  18. Respiratory Therapy Technology Program Guide.

    ERIC Educational Resources Information Center

    Georgia Univ., Athens. Dept. of Vocational Education.

    This guide presents the standard curriculum for technical institutes in Georgia. The curriculum addresses the minimum competencies for a respiratory therapy technology program. The guide contains four sections. The General Information section contains an introduction giving an overview and defining the purpose and objectives, a program…

  19. 76 FR 11288 - Draft Regulatory Guide: Issuance, Availability

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-01

    ... Guide, DG-7008, ``Leakage Tests on Packages for Shipment of Radioactive Materials.'' FOR FURTHER... regulatory guide (DG), entitled, ``Leakage Tests on Packages for Shipment of Radioactive Materials'' is... Radioactive and Nonnuclear Hazardous Materials, N14, Subcommittee of the American National Standards Institute...

  20. Medical Impairment and Computational Reduction to a Single Whole Person Impairment (WPI) Rating Value

    NASA Astrophysics Data System (ADS)

    Artz, Jerry; Alchemy, John; Weilepp, Anne; Bongiovanni, Michael; Siddhartha, Kumar

    2014-03-01

    A medical, biophysics, engineering collaboration has produced a standardized cloud-based application for creating automated WPI ratings. The project assigns numerical values to injuries/illness in accordance with the American Medical Association Guides to the Evaluation of Permanent Impairment, Fifth Edition, AMA Press handbook, 5th edition (with 63 medical contributors and 89 medical reviewers). The AMA Guide serves as the industry standard for assigning impairment values for 32 US states and 190 other countries. Clinical medical data is collected using a menu-driven user interface which is computationally combined into a single numeric value. A medical doctor performs a biometric analysis and enters the quantitative data into a mobile device. The data is analyzed using proprietary validation algorithms, and a WPI Impairment rating is created. The findings are imbedded into a formalized medicolegal report in a matter of minutes. This particular presentation will concentrate upon the WPI rating of the spine--cervical, thoracic, and lumbar. Both common rating techniques will be presented--i.e., Diagnosis Related Estimates (DRE) and Range of Motion (ROM).

  1. Endoluminal MR-guided ultrasonic applicator embedding cylindrical phased-array transducers and opposed-solenoid detection coil.

    PubMed

    Rata, Mihaela; Birlea, Vlad; Murillo, Adriana; Paquet, Christian; Cotton, François; Salomir, Rares

    2015-01-01

    MR-guided high-intensity contact ultrasound (HICU) was suggested as an alternative therapy for esophageal and rectal cancer. To offer high-quality MR guidance, two prototypes of receive-only opposed-solenoid coil were integrated with 64-element cylindrical phased-array ultrasound transducers (rectal/esophageal). The design of integrated coils took into account the transducer geometry (360° acoustic window within endoluminal space). The rectal coil was sealed on a plastic support and placed reversibly on the transducer head. The esophageal coil was fully embedded within the transducer head, resulting in one indivisible device. Comparison of integrated versus external coils was performed on a clinical 1.5T scanner. The integrated coils showed higher sensitivity compared with the standard extracorporeal coil with factors of up to 7.5 (rectal applicator) and 3.3 (esophageal applicator). High-resolution MR images for both anatomy (voxel 0.4 × 0.4 × 5 mm(3)) and thermometry (voxel 0.75 × 0.75 × 8 mm(3), 2 s/image) were acquired in vivo with the rectal endoscopic device. The temperature feedback loop accurately controlled multiple control points over the region of interest. This study showed significant improvement of MR data quality using endoluminal integrated coils versus standard external coil. Inframillimeter spatial resolution and accurate feedback control of MR-guided HICU thermotherapy were achieved. © 2014 Wiley Periodicals, Inc.

  2. Percutaneous needle placement using laser guidance: a practical solution

    NASA Astrophysics Data System (ADS)

    Xu, Sheng; Kapoor, Ankur; Abi-Jaoudeh, Nadine; Imbesi, Kimberly; Hong, Cheng William; Mazilu, Dumitru; Sharma, Karun; Venkatesan, Aradhana M.; Levy, Elliot; Wood, Bradford J.

    2013-03-01

    In interventional radiology, various navigation technologies have emerged aiming to improve the accuracy of device deployment and potentially the clinical outcomes of minimally invasive procedures. While these technologies' performance has been explored extensively, their impact on daily clinical practice remains undetermined due to the additional cost and complexity, modification of standard devices (e.g. electromagnetic tracking), and different levels of experience among physicians. Taking these factors into consideration, a robotic laser guidance system for percutaneous needle placement is developed. The laser guidance system projects a laser guide line onto the skin entry point of the patient, helping the physician to align the needle with the planned path of the preoperative CT scan. To minimize changes to the standard workflow, the robot is integrated with the CT scanner via optical tracking. As a result, no registration between the robot and CT is needed. The robot can compensate for the motion of the equipment and keep the laser guide line aligned with the biopsy path in real-time. Phantom experiments showed that the guidance system can benefit physicians at different skill levels, while clinical studies showed improved accuracy over conventional freehand needle insertion. The technology is safe, easy to use, and does not involve additional disposable costs. It is our expectation that this technology can be accepted by interventional radiologists for CT guided needle placement procedures.

  3. A reference standard-based quality assurance program for radiology.

    PubMed

    Liu, Patrick T; Johnson, C Daniel; Miranda, Rafael; Patel, Maitray D; Phillips, Carrie J

    2010-01-01

    The authors have developed a comprehensive radiology quality assurance (QA) program that evaluates radiology interpretations and procedures by comparing them with reference standards. Performance metrics are calculated and then compared with benchmarks or goals on the basis of published multicenter data and meta-analyses. Additional workload for physicians is kept to a minimum by having trained allied health staff members perform the comparisons of radiology reports with the reference standards. The performance metrics tracked by the QA program include the accuracy of CT colonography for detecting polyps, the false-negative rate for mammographic detection of breast cancer, the accuracy of CT angiography detection of coronary artery stenosis, the accuracy of meniscal tear detection on MRI, the accuracy of carotid artery stenosis detection on MR angiography, the accuracy of parathyroid adenoma detection by parathyroid scintigraphy, the success rate for obtaining cortical tissue on ultrasound-guided core biopsies of pelvic renal transplants, and the technical success rate for peripheral arterial angioplasty procedures. In contrast with peer-review programs, this reference standard-based QA program minimizes the possibilities of reviewer bias and erroneous second reviewer interpretations. The more objective assessment of performance afforded by the QA program will provide data that can easily be used for education and management conferences, research projects, and multicenter evaluations. Additionally, such performance data could be used by radiology departments to demonstrate their value over nonradiology competitors to referring clinicians, hospitals, patients, and third-party payers. Copyright 2010 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  4. Influence of illuminants on the color distribution of shade guides.

    PubMed

    Park, Ji-Hoon; Lee, Yong-Keun; Lim, Bum-Soon

    2006-12-01

    Although a shade tab in a shade guide is matched to a natural tooth in the order of value, hue, and chroma, there are limited data on the color distribution of currently available shade guides sorted by these 3 parameters. Furthermore, spectrophotometric color measurements of shade tabs differ depending on the standard illuminant employed. The purpose of this study was to determine the color distributions of 2 shade guides in value (CIE L( *)), chroma (C( *)(ab)) and hue angle (h(o)) scale relative to the standard illuminants D(65), A, and F2. Color of shade tabs (n=36) from 2 shade guides (Vita Lumin and Chromascop) were measured, and the distributions for CIE L( *), C( *)(ab) and h(o) values were compared. Color differences of shade tabs depending on the illuminant were calculated. The distributions of the ratios of CIE L( *) and C( *)(ab) values of each shade tab compared with the lowest value tab or the lowest chroma tab were determined. The data for the value, chroma, and hue angle within each shade guide were analyzed with a 2-way ANOVA with the factors of shade designation and type of illuminant (alpha=.05). Color difference caused by change of illuminant was analyzed with a 2-way ANOVA with the factors of shade designation and pair of illuminants compared (alpha=.05). The Scheffe multiple comparison test was performed as a post hoc test. CIE L( *), C( *)(ab) and h(o) values were influenced by shade designation and type of illuminant in both shade guides. Color difference caused by change of the illuminant was influenced by the shade designation and pair of illuminants compared. The order of mean color differences of 16 Vita Lumin shade tabs by pairs of illuminants compared was as follows: DeltaE( *)(ab) (D(65)/F2) = 1.63 3.7). Color distribution of 2 shade guides by the value and chroma was not logical.

  5. Determination of uncertainties associated to the in vivo measurement of iodine-131 in the thyroid.

    PubMed

    Dantas, B M; Lima, F F; Dantas, A L; Lucena, E A; Gontijo, R M G; Carvalho, C B; Hazin, C

    2016-07-01

    Intakes of radionuclides can be estimated through in vivo measurements, and the uncertainties associated to the measured activities should be clearly stated in monitoring program reports. This study aims to evaluate the uncertainties of in vivo monitoring of iodine 131 in the thyroid. The reference values for high-energy photons are based on the IDEAS Guide. Measurements were performed at the In Vivo Monitoring Laboratory of the Institute of Radiation Protection and Dosimetry (IRD) and at the Internal Dosimetry Laboratory of the Regional Center of Nuclear Sciences (CRCN-NE). In both institutions, the experiment was performed using a NaI(Tl) 3''3″ scintillation detector and a neck-thyroid phantom. Scattering factors were calculated and compared in different counting geometries. The results show that the technique produces reproducibility equivalent to the values suggested in the IDEAS Guide and measurement uncertainties is comparable to international quality standards for this type of in vivo monitoring. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Comparison of success rates, learning curves, and inter-subject performance variability of robot-assisted and manual ultrasound-guided nerve block needle guidance in simulation.

    PubMed

    Morse, J; Terrasini, N; Wehbe, M; Philippona, C; Zaouter, C; Cyr, S; Hemmerling, T M

    2014-06-01

    This study focuses on a recently developed robotic nerve block system and its impact on learning regional anaesthesia skills. We compared success rates, learning curves, performance times, and inter-subject performance variability of robot-assisted vs manual ultrasound (US)-guided nerve block needle guidance. The hypothesis of this study is that robot assistance will result in faster skill acquisition than manual needle guidance. Five co-authors with different experience with nerve blocks and the robotic system performed both manual and robot-assisted, US-guided nerve blocks on two different nerves of a nerve phantom. Ten trials were performed for each of the four procedures. Time taken to move from a shared starting position till the needle was inserted into the target nerve was defined as the performance time. A successful block was defined as the insertion of the needle into the target nerve. Average performance times were compared using analysis of variance. P<0.05 was considered significant. Data presented as mean (standard deviation). All blocks were successful. There were significant differences in performance times between co-authors to perform the manual blocks, either superficial (P=0.001) or profound (P=0.0001); no statistical difference between co-authors was noted for the robot-assisted blocks. Linear regression indicated that the average decrease in time between consecutive trials for robot-assisted blocks of 1.8 (1.6) s was significantly (P=0.007) greater than the decrease for manual blocks of 0.3 (0.3) s. Robot assistance of nerve blocks allows for faster learning of needle guidance over manual positioning and reduces inter-subject performance variability. © The Author [2014]. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. 75 FR 48382 - Draft Regulatory Guide: Issuance, Availability

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-10

    ... NUCLEAR REGULATORY COMMISSION [NRC-2010-0275] Draft Regulatory Guide: Issuance, Availability AGENCY: Nuclear Regulatory Commission. ACTION: Notice of Issuance and Availability of Draft Regulatory Guide, DG-1228, ``Standard Format and Content of License Termination Plans for Nuclear Power Reactors.'' FOR FURTHER INFORMATION CONTACT: James C....

  8. Printing/Graphic Arts Technology Program Guide.

    ERIC Educational Resources Information Center

    Georgia Univ., Athens. Dept. of Vocational Education.

    This guide presents the standard curriculum for technical institutes in Georgia. The curriculum addresses the minimum competencies for a printing/graphics technology program. It includes specializations in art and copy preparation, prepress/image assembly, and lithographic press operations. The guide contains four major sections. The General…

  9. Virginia Curriculum Management Guide.

    ERIC Educational Resources Information Center

    Virginia Commonwealth Univ., Richmond. School of Education.

    This document is a competency-based curriculum guide for use in marketing/distributive education programs in Virginia high schools. Following a section on the Virginia standards for competency-based education, the guide provides descriptions for all courses in the Virginia curriculum in the marketing/distributive education program. For each…

  10. Diagrammatic guide signs for use on controlled access highways. Volume 1, Recommendations for diagrammatic guide signs

    DOT National Transportation Integrated Search

    1972-12-01

    The purpose of the diagrammatic signing research project was to develop warrants and standards for the use of diagrammatic guide signs on controlled access highways. Volume 1 summarizes the entire diagrammatic signing research program objectives spon...

  11. 78 FR 38739 - Standard Format and Content for Post-Shutdown Decommissioning Activities Report

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-27

    ...The U.S. Nuclear Regulatory Commission (NRC) is issuing Revision 1 of Regulatory Guide (RG) 1.185, ``Standard Format and Content for Post-shutdown Decommissioning Activities Report.'' This guide describes a method that the NRC staff considers acceptable for use in complying with the Commission's requirements regarding the submission of a post-shutdown decommissioning activities report (PSDAR).

  12. 77 FR 75198 - Standard Format and Content for Post-Shutdown Decommissioning Activities Report

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-19

    ...The U.S. Nuclear Regulatory Commission (NRC) is issuing for public comment draft regulatory guide (DG), DG-1272, ``Standard Format and Content for Post-shutdown Decommissioning Activities Report.'' This guide describes a method that the NRC staff considers acceptable for use in complying with the Commission's requirements regarding the submission of a post-shutdown decommissioning activities report (PSDAR).

  13. A Guide for Developing Standard Operating Job Procedures for the Activated Sludge - Aeration & Sedimentation Process Wastewater Treatment Facility. SOJP No. 5.

    ERIC Educational Resources Information Center

    Mason, George J.

    This guide for developing standard operating job procedures for wastewater treatment facilities is devoted to the activated sludge aeration and sedimentation process. This process is for conversion of nonsettleable and nonfloatable materials in wastewater to settleable, floculated biological groups and separation of the settleable solids from the…

  14. A Guide for Developing Standard Operating Job Procedures for the Tertiary Chemical Treatment - Lime Precipitation Process Wastewater Treatment Facility. SOJP No. 6.

    ERIC Educational Resources Information Center

    Petrasek, Al, Jr.

    This guide describes the standard operating job procedures for the tertiary chemical treatment - lime precipitation process of wastewater treatment plants. Step-by-step instructions are given for pre-start up, start-up, continuous operation, and shut-down procedures. In addition, some theoretical material is presented along with some relevant…

  15. A Guide for Developing Standard Operating Job Procedures for the Grit Removal Process Wastewater Treatment Facility. SOJP No. 2.

    ERIC Educational Resources Information Center

    Deal, Gerald A.; Montgomery, James A.

    This guide describes standard operating job procedures for the grit removal process of wastewater treatment plants. Step-by-step instructions are given for pre-start up inspection, start-up, continuous operation, and shut-down procedures. A description of the equipment used in the process is given. Some theoretical material is presented. (BB)

  16. Common Core Standards for High School English Language Arts: A Quick-Start Guide

    ERIC Educational Resources Information Center

    Kendall, John; Frazee, Dana; Ryan, Susan

    2012-01-01

    High school teachers and leaders with responsibility for English language arts (ELA) need this handy guide to successfully implement the Common Core in their respective grade levels. Getting a copy for every staff member ensures they know: (1) How grades 11-12 ELA content differs from and builds upon 9-10 standards; (2) How the four strands…

  17. Social Studies: Grades 4, 8, & 11. Content Specifications for Statewide Assessment by Standard.

    ERIC Educational Resources Information Center

    Missouri State Dept. of Elementary and Secondary Education, Jefferson City.

    This state of Missouri guide to content specifications for social studies assessment is designed to give teachers direction for assessment at the benchmark levels of grades 4, 8, and 11 for each standard that is appropriate for a statewide assessment. The guide includes specifications of what students are expected to know at the benchmark levels…

  18. [Three good reasons to perform a postmortem examination in all cases of juvenile sudden death].

    PubMed

    d'Amati, Giulia; di Gioia, Cira R T; Silenzi, Paola F; Gallo, Pietro

    2009-04-01

    The aim of this review is to underline the reasons why a post-mortem examination has to be performed in all cases of juvenile sudden death. Sudden death in children and young adults can be caused by potentially heritable cardiovascular disorders and fatal outcome is often the first symptom in apparently healthy subjects. In these cases, a careful autopsy, performed according to a standardized protocol, becomes the sole diagnostic tool to guide clinical and molecular genetic family screening and to adopt the proper therapeutic and preventive strategies. Thus, a post-mortem examination is a fundamental part of a multidisciplinary approach to the issue of juvenile sudden death.

  19. Contribution of diagnostic tests for the etiological assessment of uveitis, data from the ULISSE study (Uveitis: Clinical and medicoeconomic evaluation of a standardized strategy of the etiological diagnosis).

    PubMed

    Grumet, Pierre; Kodjikian, Laurent; de Parisot, Audrey; Errera, Marie-Hélène; Sedira, Neila; Heron, Emmanuel; Pérard, Laurent; Cornut, Pierre-Loïc; Schneider, Christelle; Rivière, Sophie; Ollé, Priscille; Pugnet, Grégory; Cathébras, Pascal; Manoli, Pierre; Bodaghi, Bahram; Saadoun, David; Baillif, Stéphanie; Tieulie, Nathalie; Andre, Marc; Chiambaretta, Frédéric; Bonin, Nicolas; Bielefeld, Philip; Bron, Alain; Mouriaux, Frédéric; Bienvenu, Boris; Vicente, Stéphanie; Bin, Sylvie; Labetoulle, Marc; Broussolle, Christiane; Jamilloux, Yvan; Decullier, Evelyne; Sève, Pascal

    2018-04-01

    ULISSE is the only study that prospectively assessed the efficiency of a standardized strategy, compared to an open strategy for the etiologic diagnosis of uveitis. Our aim was to evaluate the diagnostic yield of the tests prescribed in the ULISSE study to clarify their relevance. ULISSE is a non-inferiority, prospective, multicenter and cluster randomized study. The standardized strategy is a two-steps strategy: in the first step, common standard tests were performed, and in the second step, tests were guided by the clinical and anatomic type of uveitis. We reported the relevance of the diagnostic tests used in the standardized strategy, as well as the profitability of the tests that were prescribed to more than twenty patients in each group. Based on diagnostic criteria, either an ophthalmologist, or an internist, established the profitability of a test by considering whether the test lead to a diagnosis or not. Among the 676 patients included (standardized 303; open 373), a diagnosis was made for 152 (50.4%) in the standardized group and 203 (54.4%) in the open group. The most common entities were HLA-B27 associated uveitis (22%), spondyloarthritis (11%), sarcoidosis (18%), tuberculosis (10.7%) and herpes virus infections (8.5%). Among the first step's systematic tests, tuberculin skin test was the most contributive investigation (17.1%), followed by chest X-ray (8.4%), C reactive protein and ESR (6.6% and 5.1%), complete blood count (2.2%) and VDRL (2.0%). The second step's most often contributive tests were: HLA B27 (56.3%), chest-CT (30.3%) and angiotensin converting enzyme (ACE) (16.5%). HLA B27 and ACE were significantly more contributive in the standardized group than in the open group. Immunological tests were never contributive. Among the free investigations, or among the investigations guided by clinical or paraclinical findings, the most often contributive tests were: Quantiferon® (24%), electrophoresis of serum protein (7.8%) and sacroiliac imagery (46.4%). Intracellular serologies (1.7%), serum calcium (2.1%) and hepatic tests (3.3%) were exceptionally contributive. Among the third intention tests, labial salivary gland biopsies were contributive in 17.9% of cases, but the profitability of other invasive investigations (anterior chamber tap, vitrectomy, bronchoscopy and lumbar puncture) or specialized imagery (18F-FDG PET, Brain MRI) could not be determined since these test were rarely performed. Only a few diagnostic tests are useful for the etiological assessment of uveitis. They are often cheap, simple, more often guided by the clinical findings, and lead to an etiological diagnosis in most patients. On the other hand, some tests are never or exceptionally contributive, such as immunological tests or intracellular serologies. Further studies are required to evaluate the profitability of third intention imagery and invasive investigations. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Associate Degree Nursing Program Guide. Final Report from February 19, 1985 to August 31, 1985.

    ERIC Educational Resources Information Center

    Seminole Community Coll., Sanford, FL.

    This program guide is intended to help Associate Degree Nursing (ADN) instructors in Florida develop and/or update ADN programs. The first part is the final report of the project that developed the guide. Section I of the guide provides a description of the occupation, student admission criteria, retention and withdrawal standards, and program…

  1. Electromagnetic Real Time Navigation in the Region of the Posterior Pelvic Ring: An Experimental In-Vitro Feasibility Study and Comparison of Image Guided Techniques.

    PubMed

    Pishnamaz, Miguel; Wilkmann, Christoph; Na, Hong-Sik; Pfeffer, Jochen; Hänisch, Christoph; Janssen, Max; Bruners, Philipp; Kobbe, Philipp; Hildebrand, Frank; Schmitz-Rode, Thomas; Pape, Hans-Christoph

    2016-01-01

    Electromagnetic tracking is a relatively new technique that allows real time navigation in the absence of radiation. The aim of this study was to prove the feasibility of this technique for the treatment of posterior pelvic ring fractures and to compare the results with established image guided procedures. Tests were performed in pelvic specimens (Sawbones®) with standardized sacral fractures (Type Denis I or II). A gel matrix simulated the operative approach and a cover was used to disable visual control. The electromagnetic setup was performed by using a custom made carbon reference plate and a prototype stainless steel K-wire with an integrated sensor coil. Four different test series were performed: Group OCT: Optical navigation using preoperative CT-scans; group O3D: Optical navigation using intraoperative 3-D-fluoroscopy; group Fluoro: Conventional 2-D-fluoroscopy; group EMT: Electromagnetic navigation combined with a preoperative Dyna-CT. Accuracy of screw placement was analyzed by standardized postoperative CT-scan for each specimen. Operation time and intraoperative radiation exposure for the surgeon was documented. All data was analyzed using SPSS (Version 20, 76 Chicago, IL, USA). Statistical significance was defined as p< 0.05. 160 iliosacral screws were placed (40 per group). EMT resulted in a significantly higher incidence of optimal screw placement (EMT: 36/40) compared to the groups Fluoro (30/40; p< 0.05) and OCT (31/40; p< 0.05). Results between EMT and O3D were comparable (O3D: 37/40; n.s.). Also, the operation time was comparable between groups EMT and O3D (EMT 7.62 min vs. O3D 7.98 min; n.s.), while the surgical time was significantly shorter compared to the Fluoro group (10.69 min; p< 0.001) and the OCT group (13.3 min; p< 0.001). Electromagnetic guided iliosacral screw placement is a feasible procedure. In our experimental setup, this method was associated with improved accuracy of screw placement and shorter operation time when compared with the conventional fluoroscopy guided technique and compared to the optical navigation using preoperative CT-scans. Further studies are necessary to rule out drawbacks of this technique regarding ferromagnetic objects.

  2. Augmented reality fluoroscopy simulation of the guide-wire insertion in DHS surgery: A proof of concept study.

    PubMed

    van Duren, B H; Sugand, K; Wescott, R; Carrington, R; Hart, A

    2018-05-01

    Hip fractures contribute to a significant clinical burden globally with over 1.6 million cases per annum and up to 30% mortality rate within the first year. Insertion of a dynamic hip screw (DHS) is a frequently performed procedure to treat extracapsular neck of femur fractures. Poorly performed DHS fixation of extracapsular neck of femur fractures can result in poor mobilisation, chronic pain, and increased cut-out rate requiring revision surgery. A realistic, affordable, and portable fluoroscopic simulation system can improve performance metrics in trainees, including the tip-apex distance (the only clinically validated outcome), and improve outcomes. We developed a digital fluoroscopic imaging simulator using orthogonal cameras to track coloured markers attached to the guide-wire which created a virtual overlay on fluoroscopic images of the hip. To test the accuracy with which the augmented reality system could track a guide-wire, a standard workshop femur was used to calibrate the system with a positional marker fixed to indicate the apex; this allowed for comparison between guide-wire tip-apex distance (TAD) calculated by the system to be compared to that physically measured. Tests were undertaken to determine: (1) how well the apex could be targeted; (2) the accuracy of the calculated TAD. (3) The number of iterations through the algorithm giving the optimal accuracy-time relationship. The calculated TAD was found to have an average root mean square error of 4.2 mm. The accuracy of the algorithm was shown to increase with the number of iterations up to 20 beyond which the error asymptotically converged to an error of 2 mm. This work demonstrates a novel augmented reality simulation of guide-wire insertion in DHS surgery. To our knowledge this has not been previously achieved. In contrast to virtual reality, augmented reality is able to simulate fluoroscopy while allowing the trainee to interact with real instrumentation and performing the procedure on workshop bone models. Copyright © 2018 IPEM. Published by Elsevier Ltd. All rights reserved.

  3. A guide to performing basic manifest refractometry.

    PubMed

    Garber, N

    2000-01-01

    Refractometry provides the ophthalmologist with the prescription that has the most plus power with the best vision. This eliminates the need for the patient accommodating to achieve clear vision at distance. Flowcharts, of the refractometry process, help the refractionist use standard procedures to accurately arrive at the correct baseline prescription for the patient's refractive state. By using the patient's history of subjective complaints, past refractive corrections, and present visual needs, the ophthalmologist then can prescribe the final prescription.

  4. Simulation of Adaptive Seat Energy Absorber for Military Rotorcraft Crash Safety Enhancement

    DTIC Science & Technology

    2014-04-01

    design guidelines and detailed requirements were developed for military crew seats as defined in MIL-S-85510(AS) (12) and for civil rotorcraft seats in...rotorcraft vertical crash pulse as stipulated in military design standards was used to evaluate the performance of MREA seat energy absorber with a...Desjardins, S. P.; Zimmerman, R. E.; Bolukbasi, A. O.; Merritt, N. A. Aircraft Crash Survival Design Guide Vol. IV – Aircraft Seats , Restraints, Litters

  5. Teaching medical students ultrasound-guided vascular access - which learning method is best?

    PubMed

    Lian, Alwin; Rippey, James C R; Carr, Peter J

    2017-05-15

    Ultrasound is recommended to guide insertion of peripheral intravenous vascular cannulae (PIVC) where difficulty is experienced. Ultrasound machines are now common-place and junior doctors are often expected to be able to use them. The educational standards for this skill are highly varied, ranging from no education, to self-guided internet-based education, to formal, face-to-face traditional education. In an attempt to decide which educational technique our institution should introduce, a small pilot trial comparing educational techniques was designed. Thirty medical students were enrolled and allocated to one of three groups. PIVC placing ability was then observed, tested and graded on vascular access phantoms. The formal, face-to-face traditional education was rated best by the students, and had the highest success rate in PIVC placement, the improvement statistically significant compared to no education (p = 0.01) and trending towards significance when compared to self-directed internet-based education (p<0.06). The group receiving traditional face-to-face teaching on ultrasound-guided vascular access, performed significantly better than those not receiving education. As the number of ultrasound machines in clinical areas increases, it is important that education programs to support their safe and appropriate use are developed.

  6. A guide to defining the competence required of a consultant in clinical chemistry and laboratory medicine.

    PubMed

    Beastall, Graham; Kenny, Desmond; Laitinen, Paivi; ten Kate, Joop

    2005-01-01

    A definition has been agreed for the most senior professional (consultant) in clinical chemistry and laboratory medicine. A model job description for a consultant has been determined, which is intended to act as a toolkit to assist employing authorities and professional bodies to define the role of individual consultant posts. A total of 86 competences for a consultant have been designated and expressed in the form of simple generic proficiency standards. These competences have been allocated to six broad areas: clinical [13]; scientific [15]; technical [12]; communication [12]; management and leadership [20]; professional autonomy and accountability [14]. The competences are intended to be illustrative rather than definitive and to enable the duties of any consultant post to be defined. Assessment of competence is likely to entail consideration of qualifications, registration status, continuing professional development and performance review. The project is intended as a guide to European societies of clinical chemistry and laboratory medicine. The guide should be capable of local interpretation to encourage a greater degree of commonality in the role of the consultant whilst protecting national identity. The guide should stimulate international understanding and collaboration and contribute to an overall improvement in the quality of practice.

  7. Statistical Validation of Brain Tumor Shape Approximation via Spherical Harmonics for Image-Guided Neurosurgery1

    PubMed Central

    Goldberg-Zimring, Daniel; Talos, Ion-Florin; Bhagwat, Jui G.; Haker, Steven J.; Black, Peter M.; Zou, Kelly H.

    2005-01-01

    Rationale and Objectives Surgical planning now routinely uses both two-dimensional (2D) and three-dimensional (3D) models that integrate data from multiple imaging modalities, each highlighting one or more aspects of morphology or function. We performed a preliminary evaluation of the use of spherical harmonics (SH) in approximating the 3D shape and estimating the volume of brain tumors of varying characteristics. Materials and Methods Magnetic resonance (MR) images from five patients with brain tumors were selected randomly from our MR-guided neurosurgical practice. Standardized mean square reconstruction errors (SMSRE) by tumor volume were measured. Validation metrics for comparing performances of the SH method against segmented contours (SC) were the dice similarity coefficient (DSC) and standardized Euclidean distance (SED) measure. Results Tumor volume range was 22413–85189 mm3, and range of number of vertices in triangulated models was 3674–6544. At SH approximations with degree of at least 30, SMSRE were within 1.66 × 10−5 mm−1. Summary measures yielded a DSC range of 0.89–0.99 (pooled median, 0.97 and significantly >0.7; P < .001) and an SED range of 0.0002–0.0028 (pooled median, 0.0005). Conclusion 3D shapes of tumors may be approximated by using SH for neurosurgical applications. PMID:15831419

  8. Health software: a new CEI Guide for software management in medical environment.

    PubMed

    Giacomozzi, Claudia; Martelli, Francesco

    2016-01-01

    The increasing spread of software components in the healthcare context renders explanatory guides relevant and mandatory to interpret laws and standards, and to support safe management of software products in healthcare. In 2012 a working group has been settled for the above purposes at Italian Electrotechnical Committee (CEI), made of experts from Italian National Institute of Health (ISS), representatives of industry, and representatives of the healthcare organizations. As a first outcome of the group activity, Guide CEI 62-237 was published in February 2015. The Guide incorporates an innovative approach based on the proper contextualization of software products, either medical devices or not, to the specific healthcare scenario, and addresses the risk management of IT systems. The Guide provides operators and manufacturers with an interpretative support with many detailed examples to facilitate the proper contextualization and management of health software, in compliance with related European and international regulations and standards.

  9. Versatile utilization of real-time intraoperative contrast-enhanced ultrasound in cranial neurosurgery: technical note and retrospective case series.

    PubMed

    Lekht, Ilya; Brauner, Noah; Bakhsheshian, Joshua; Chang, Ki-Eun; Gulati, Mittul; Shiroishi, Mark S; Grant, Edward G; Christian, Eisha; Zada, Gabriel

    2016-03-01

    Intraoperative contrast-enhanced ultrasound (iCEUS) offers dynamic imaging and provides functional data in real time. However, no standardized protocols or validated quantitative data exist to guide its routine use in neurosurgery. The authors aimed to provide further clinical data on the versatile application of iCEUS through a technical note and illustrative case series. Five patients undergoing craniotomies for suspected tumors were included. iCEUS was performed using a contrast agent composed of lipid shell microspheres enclosing perflutren (octafluoropropane) gas. Perfusion data were acquired through a time-intensity curve analysis protocol obtained using iCEUS prior to biopsy and/or resection of all lesions. Three primary tumors (gemistocytic astrocytoma, glioblastoma multiforme, and meningioma), 1 metastatic lesion (melanoma), and 1 tumefactive demyelinating lesion (multiple sclerosis) were assessed using real-time iCEUS. No intraoperative complications occurred following multiple administrations of contrast agent in all cases. In all neoplastic cases, iCEUS replicated enhancement patterns observed on preoperative Gd-enhanced MRI, facilitated safe tumor debulking by differentiating neoplastic tissue from normal brain parenchyma, and helped identify arterial feeders and draining veins in and around the surgical cavity. Intraoperative CEUS was also useful in guiding a successful intraoperative needle biopsy of a cerebellar tumefactive demyelinating lesion obtained during real-time perfusion analysis. Intraoperative CEUS has potential for safe, real-time, dynamic contrast-based imaging for routine use in neurooncological surgery and image-guided biopsy. Intraoperative CEUS eliminates the effect of anatomical distortions associated with standard neuronavigation and provides quantitative perfusion data in real time, which may hold major implications for intraoperative diagnosis, tissue differentiation, and quantification of extent of resection. Further prospective studies will help standardize the role of iCEUS in neurosurgery.

  10. The Navy/NASA Engine Program (NNEP89): A user's manual

    NASA Technical Reports Server (NTRS)

    Plencner, Robert M.; Snyder, Christopher A.

    1991-01-01

    An engine simulation computer code called NNEP89 was written to perform 1-D steady state thermodynamic analysis of turbine engine cycles. By using a very flexible method of input, a set of standard components are connected at execution time to simulate almost any turbine engine configuration that the user could imagine. The code was used to simulate a wide range of engine cycles from turboshafts and turboprops to air turborockets and supersonic cruise variable cycle engines. Off design performance is calculated through the use of component performance maps. A chemical equilibrium model is incorporated to adequately predict chemical dissociation as well as model virtually any fuel. NNEP89 is written in standard FORTRAN77 with clear structured programming and extensive internal documentation. The standard FORTRAN77 programming allows it to be installed onto most mainframe computers and workstations without modification. The NNEP89 code was derived from the Navy/NASA Engine program (NNEP). NNEP89 provides many improvements and enhancements to the original NNEP code and incorporates features which make it easier to use for the novice user. This is a comprehensive user's guide for the NNEP89 code.

  11. Surgical Technology Program Guide.

    ERIC Educational Resources Information Center

    Georgia Univ., Athens. Dept. of Vocational Education.

    This surgical technology program guide presents the standard curriculum for technical institutes in Georgia. The curriculum addresses the minimum competencies for a surgical technology program. The program guide is designed to relate primarily to the development of those skills needed by individuals in the field to provide services in the…

  12. 75 FR 28073 - Draft Regulatory Guide: Issuance, Availability

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-19

    ... NUCLEAR REGULATORY COMMISSION [NRC-2010-0181] Draft Regulatory Guide: Issuance, Availability AGENCY: Nuclear Regulatory Commission. ACTION: Notice of Issuance and Availability of Draft Regulatory Guide, DG-3039, ``Standard Format and Content for Emergency Plans for Fuel Cycle and Materials Facilities.'' FOR FURTHER INFORMATION CONTACT: Kevin M....

  13. 76 FR 24539 - Final Regulatory Guide: Issuance, Availability

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-02

    ... NUCLEAR REGULATORY COMMISSION [NRC-2010-0181] Final Regulatory Guide: Issuance, Availability AGENCY: Nuclear Regulatory Commission. ACTION: Notice of Issuance and Availability of Regulatory Guide (RG) 3.67, ``Standard Format and Content for Emergency Plans for Fuel Cycle and Materials Facilities.'' FOR FURTHER INFORMATION CONTACT: Kevin M. Ramse...

  14. 0-6782 : development of design standards for mounting temporary large guide signs.

    DOT National Transportation Integrated Search

    2014-08-01

    A common issue during phased highway : construction projects is the need to temporarily : relocate large guide signs on the roadside or install : new guide signs for temporary use. Many of these : signs are larger than 100 ft2 in size and cannot be :...

  15. Model Training Guide. Firefighter I.

    ERIC Educational Resources Information Center

    Hagevig, William A.; Gallagher, Leigh S.

    This firefighter training guide for a 180-hour course was developed to assist training officers in planning training with emphasis on conformance to recommended National Fire Protection Association (NFPA 1001) standards. The material in the guide is referenced to current editions of the International Fire Service Training Association manuals and…

  16. Communicating Test Results: A Training Guide. Final Report.

    ERIC Educational Resources Information Center

    Phelps, William R.

    This training guide is prepared primarily for the professional practitioner; however, academicians may find the guide to have considerable value in both graduate and undergraduate courses in the helping services. The material presents techniques and methods for communicating test results of a psychometric nature, suggested standards for…

  17. National Emission Standards for Hazardous Air Pollutants (NESHAP) for Area Source Boilers Tune-up Guides

    EPA Pesticide Factsheets

    This page contains two tune-up guides for area source boilers for industrial, commercial, and institutional boilers and process heaters. The first guide is for owners and operators, and the second is for technicians for the area source boilers.

  18. A CMOS-based high-resolution fluoroscope (HRF) detector prototype with 49.5μm pixels for use in endovascular image guided interventions (EIGI)

    NASA Astrophysics Data System (ADS)

    Russ, M.; Shankar, A.; Setlur Nagesh, S. V.; Ionita, C. N.; Bednarek, D. R.; Rudin, S.

    2017-03-01

    X-ray detectors to meet the high-resolution requirements for endovascular image-guided interventions (EIGIs) are being developed and evaluated. A new 49.5-micron pixel prototype detector is being investigated and compared to the current suite of high-resolution fluoroscopic (HRF) detectors. This detector featuring a 300-micron thick CsI(Tl) scintillator, and low electronic noise CMOS readout is designated the HRF- CMOS50. To compare the abilities of this detector with other existing high resolution detectors, a standard performance metric analysis was applied, including the determination of the modulation transfer function (MTF), noise power spectra (NPS), noise equivalent quanta (NEQ), and detective quantum efficiency (DQE) for a range of energies and exposure levels. The advantage of the smaller pixel size and reduced blurring due to the thin phosphor was exemplified when the MTF of the HRF-CMOS50 was compared to the other high resolution detectors, which utilize larger pixels, other optical designs or thicker scintillators. However, the thinner scintillator has the disadvantage of a lower quantum detective efficiency (QDE) for higher diagnostic x-ray energies. The performance of the detector as part of an imaging chain was examined by employing the generalized metrics GMTF, GNEQ, and GDQE, taking standard focal spot size and clinical imaging parameters into consideration. As expected, the disparaging effects of focal spot unsharpness, exacerbated by increasing magnification, degraded the higher-frequency performance of the HRF-CMOS50, while increasing scatter fraction diminished low-frequency performance. Nevertheless, the HRF-CMOS50 brings improved resolution capabilities for EIGIs, but would require increased sensitivity and dynamic range for future clinical application.

  19. Development of national standardized all-hazard disaster core competencies for acute care physicians, nurses, and EMS professionals.

    PubMed

    Schultz, Carl H; Koenig, Kristi L; Whiteside, Mary; Murray, Rick

    2012-03-01

    The training of medical personnel to provide care for disaster victims is a priority for the physician community, the federal government, and society as a whole. Course development for such training guided by well-accepted standardized core competencies is lacking, however. This project identified a set of core competencies and performance objectives based on the knowledge, skills, and attitudes required by the specific target audience (emergency department nurses, emergency physicians, and out-of-hospital emergency medical services personnel) to ensure they can treat the injuries and illnesses experienced by victims of disasters regardless of cause. The core competencies provide a blueprint for the development or refinement of disaster training courses. This expert consensus project, supported by a grant from the Robert Wood Johnson Foundation, incorporated an all-hazard, comprehensive emergency management approach addressing every type of disaster to minimize the effect on the public's health. An instructional systems design process was used to guide the development of audience-appropriate competencies and performance objectives. Participants, representing multiple academic and provider organizations, used a modified Delphi approach to achieve consensus on recommendations. A framework of 19 content categories (domains), 19 core competencies, and more than 90 performance objectives was developed for acute medical care personnel to address the requirements of effective all-hazards disaster response. Creating disaster curricula and training based on the core competencies and performance objectives identified in this article will ensure that acute medical care personnel are prepared to treat patients and address associated ramifications/consequences during any catastrophic event. Copyright © 2012 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.

  20. A Guide for Parents and Families about What Your 10th Grader Should Be Learning in School This Year. Don't Fail Your Children = Una Guia para los Padres y Familias Acerca de Lo Que Su Hijo de Decimo Grado Debe Aprender en la Escuela Este Ano. No Le Falle a Sus Hijos.

    ERIC Educational Resources Information Center

    South Carolina State Education Oversight Committee, Columbia.

    This guide, in English- and Spanish-language versions, shares with parents information about the South Carolina Curriculum Standards. The standards outline state requirements for children's learning and what students across the state should be able to do in certain subjects. The guide lists seven key reasons parents should be aware of the new…

  1. A Guide for Parents and Families about What Your 5th Grader Should Be Learning in School This Year. Don't Fail Your Children = Una Guia para los Padres y Familias Acerca de Lo Que Su Hijo de 5to Grado Debe Aprender en la Escuela Este Ano. No Le Falle a Sus Hijos.

    ERIC Educational Resources Information Center

    South Carolina State Dept. of Education, Columbia.

    This guide, in English- and Spanish-language versions, shares with parents information about the South Carolina Curriculum Standards. The standards outline state requirements for children's learning and what students across the state should be able to do in certain subjects. The guide lists seven key reasons parents should be aware of the new…

  2. A Guide for Parents and Families about What Your Kindergartner Should Be Learning in School This Year. Don't Fail Your Children = Una Guia para los Padres y Familias Acerca de Lo Que Su Hijo de Jardin Infantil (Kindergarten) Debe Aprender en la Escuela Este Ano. No Le Falle a Sus Hijos.

    ERIC Educational Resources Information Center

    South Carolina State Dept. of Education, Columbia.

    This guide, in English- and Spanish-language versions, shares with parents information about the South Carolina Curriculum Standards. The standards outline state requirements for children's learning and what students across the state should be able to do in certain subjects. The guide lists seven key reasons parents should be aware of the new…

  3. A Guide for Parents and Families about What Your 6th Grader Should Be Learning in School This Year. Don't Fail Your Children = Una Guia para los Padres y Familias Acerca de Lo Que Su Hijo de 6to Grado Debe Aprender en la Escuela Este Ano. No Le Falle a Sus Hijos.

    ERIC Educational Resources Information Center

    South Carolina State Dept. of Education, Columbia.

    This guide, in English- and Spanish-language versions, shares with parents information about the South Carolina Curriculum Standards. The standards outline state requirements for children's learning and what students across the state should be able to do in certain subjects. The guide lists seven key reasons parents should be aware of the new…

  4. A Guide for Parents and Families about What Your 3rd Grader Should Be Learning in School This Year. Don't Fail Your Children = Una Guia para los Padres y Familias Acerca de Lo Que Su Hijo de 3er Grado Debe Aprender en la Escuela Este Ano. No Le Falle a Sus Hijos.

    ERIC Educational Resources Information Center

    South Carolina State Dept. of Education, Columbia.

    This guide, in English- and Spanish-language versions, shares with parents information about the South Carolina Curriculum Standards. The standards outline state requirements for children's learning and what students across the state should be able to do in certain subjects. The guide lists seven key reasons parents should be aware of the new…

  5. A Guide for Parents and Families about What Your 11th Grader Should Be Learning in School This Year. Don't Fail Your Children = Una Guia para los Padres y Familias Acerca de Lo Que Su Hijo de Grado 11 Debe Aprender en la Escuela Este Ano. No Le Falle a Sus Hijos.

    ERIC Educational Resources Information Center

    South Carolina State Dept. of Education, Columbia.

    This guide, in English- and Spanish-language versions, shares with parents information about the South Carolina Curriculum Standards. The standards outline state requirements for children's learning and what students across the state should be able to do in certain subjects. The guide lists seven key reasons parents should be aware of the new…

  6. A Guide for Parents and Families about What Your 9th Grader Should Be Learning in School This Year. Don't Fail Your Children = Una Guia para los Padres y Familias Acerca de Lo Que Su Hijo de Noveno Grado Debe Aprender en la Escuela Este Ano. No Le Falle a Sus Hijos.

    ERIC Educational Resources Information Center

    South Carolina State Dept. of Education, Columbia.

    This guide, in English- and Spanish-language versions, shares with parents information about the South Carolina Curriculum Standards. The standards outline state requirements for children's learning and what students across the state should be able to do in certain subjects. The guide lists seven key reasons parents should be aware of the new…

  7. A Guide for Parents and Families about What Your 7th Grader Should Be Learning in School This Year. Don't Fail Your Children = Una Guia para los Padres y Familias Acerca de Lo Que Su Hijo de Septimo Grado Debe Aprender en la Escuela Este Ano. No Le Falle a Sus Hijos.

    ERIC Educational Resources Information Center

    South Carolina State Dept. of Education, Columbia.

    This guide, in English- and Spanish-language versions, shares with parents information about the South Carolina Curriculum Standards. The standards outline state requirements for children's learning and what students across the state should be able to do in certain subjects. The guide lists seven key reasons parents should be aware of the new…

  8. A Guide for Parents and Families about What Your 1st Grader Should Be Learning in School This Year. Don't Fail Your Children = Una Guia para los Padres y Familias Acerca de Lo Que Su Hijo de 1er Grado Debe Aprender en la Escuela Este Ano. No Le Falle a Sus Hijos.

    ERIC Educational Resources Information Center

    South Carolina State Dept. of Education, Columbia.

    This guide, in English- and Spanish-language versions, shares with parents information about the South Carolina Curriculum Standards. The standards outline state requirements for children's learning and what students across the state should be able to do in certain subjects. The guide lists seven key reasons parents should be aware of the new…

  9. A Guide for Parents and Families about What Your 8th Grader Should Be Learning in School This Year. Don't Fail Your Children = Una Guia para los Padres y Familias Acerca de Lo Que Su Hijo de Octavo Grado Debe Aprender en la Escuela Este Ano. No Le Falle a Sus Hijos.

    ERIC Educational Resources Information Center

    South Carolina State Dept. of Education, Columbia.

    This guide, in English- and Spanish-language versions, shares with parents information about the South Carolina Curriculum Standards. The standards outline state requirements for children's learning and what students across the state should be able to do in certain subjects. The guide lists seven key reasons parents should be aware of the new…

  10. A Guide for Parents and Families about What Your 2nd Grader Should Be Learning in School This Year. Don't Fail Your Children = Una Guia para los Padres y Familias Acerca de Lo Que Su Hijo de 2do Grado Debe Aprender en la Escuela Este Ano. No Le Falle a Sus Hijos.

    ERIC Educational Resources Information Center

    South Carolina State Dept. of Education, Columbia.

    This guide, in English- and Spanish-language versions, shares with parents information about the South Carolina Curriculum Standards. The standards outline state requirements for children's learning and what students across the state should be able to do in certain subjects. The guide lists seven key reasons parents should be aware of the new…

  11. A Guide for Parents and Families about What Your 4th Grader Should Be Learning in School This Year. Don't Fail Your Children = Una Guia para los Padres y Familias Acerca de Lo Que Su Hijo de 4to Grado Debe Aprender en la Escuela Este Ano. No Le Falle a Sus Hijos.

    ERIC Educational Resources Information Center

    South Carolina State Dept. of Education, Columbia.

    This guide, in English- and Spanish-language versions, shares with parents information about the South Carolina Curriculum Standards. The standards outline state requirements for children's learning and what students across the state should be able to do in certain subjects. The guide lists seven key reasons parents should be aware of the new…

  12. Mercury Atomic Frequency Standards for Space Based Navigation and Timekeeping

    NASA Technical Reports Server (NTRS)

    Tjoelker, R. L.; Burt, E. A.; Chung, S.; Hamell, R. L.; Prestage, J. D.; Tucker, B.; Cash, P.; Lutwak, R.

    2012-01-01

    A low power Mercury Atomic Frequency Standard (MAFS) has been developed and demonstrated on the path towards future space clock applications. A self contained mercury ion breadboard clock: emulating flight clock interfaces, steering a USO local oscillator, and consuming approx 40 Watts has been operating at JPL for more than a year. This complete, modular ion clock instrument demonstrates that key GNSS size, weight, and power (SWaP) requirements can be achieved while still maintaining short and long term performance demonstrated in previous ground ion clocks. The MAFS breadboard serves as a flexible platform for optimizing further space clock development and guides engineering model design trades towards fabrication of an ion clock for space flight.

  13. OpenEIS. Users Guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Woohyun; Lutes, Robert G.; Katipamula, Srinivas

    This document is a users guide for OpenEIS, a software code designed to provide standard methods for authoring, sharing, testing, using and improving algorithms for operational building energy efficiency.

  14. Is It Important to Adapt Neoadjuvant Chemotherapy to the Visible Clinical Response? An Open Randomized Phase II Study Comparing Response-Guided and Standard Treatments in HER2-Negative Operable Breast Cancer

    PubMed Central

    Mouret-Reynier, Marie-Ange; Savoye, Aude-Marie; Abrial, Catherine; Kwiatkowski, Fabrice; Garbar, Christian; DuBray-Longeras, Pascale; Eymard, Jean-Christophe; Lebouedec, Guillaume; Vanpraagh, Isabelle; Penault-Llorca, Frederique; Chollet, Philippe; Cure, Hervé

    2015-01-01

    Background. Neoadjuvant treatment provides a unique opportunity to evaluate individual tumor sensitivity. This study evaluated whether a response-guided strategy could improve clinical outcome compared with a standard treatment. Methods. Overall, 264 previously untreated stage II–III operable breast cancer patients were randomized to receive either standard treatment (arm A, n = 131), consisting of fluorouracil, epirubicin, and cyclophosphamide (FEC100: 500, 100, and 500 mg/m2, respectively, for 3 cycles) followed by docetaxel (100 mg/m2 for 3 cycles), or adapted treatment (arm B, n = 133), beginning with 2 cycles of FEC100 and switching to docetaxel if tumor size decreased by <30% after 2 cycles or <50% after 4 cycles of FEC100 (ultrasound assessments according to World Health Organization criteria). Otherwise, FEC100 was given for six cycles before surgery. Intent-to-treat analysis was performed. Results. Similar results were observed for clinical response (objective response was 54% vs 56%, p = .18), breast conservation surgery (BCS; 67% vs 68%, p = .97), and pathological complete response rate (Chevallier classification: 14% vs 11%, p = .68; Statloff classification: 16% vs 13%, p = .82) between arms A and B. Similar toxicities were observed, even with unbalanced numbers of FEC100 and docetaxel courses. Conclusion. Adapted and standard treatments had similar results in terms of tumor response, BCS rate, and tolerability. Further survival outcome data are expected. PMID:25637380

  15. Microbubble-enhanced ultrasound to demonstrate urethral transection in a case of penile fracture.

    PubMed

    Czarnecki, Oliver; von Stempel, Conrad Brice; Sangster, Pippa; Walkden, Miles

    2017-09-23

    A 47-year-old man attended the emergency department following trauma during sexual intercourse after which he developed penile swelling and haematuria several hours later. A penile fracture was suspected but given the slightly atypical history, ultrasound was performed to look for a fracture. Given the history of haematuria, both a standard Doppler ultrasound and a microbubble-enhanced retrograde ultrasound urethrogram were performed. The Doppler confirmed the suspected diagnosis of penile fracture, and microbubble urethrogram demonstrated a urethral injury. This facilitated prompt surgical treatment and helped guide the surgical approach. Retrograde microbubble enhanced ultrasound urethrogram is a novel technique that can be used in conjunction with standard ultrasound to confirm the presence of a concurrent urethral rupture in penile fracture. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  16. Definition of Unfit for Standard Acute Myeloid Leukemia Therapy.

    PubMed

    Klepin, Heidi D

    2016-12-01

    Determining who is fit or unfit for standard treatments among older adults with acute myeloid leukemia (AML) remains a challenge. However, available evidence can provide guidance on strategies to assess and categorize fitness. Evidence is strongest to guide identification of "frail" older adults at the time of diagnosis based on performance status, physical function, and comorbidity. Many older adults, with adequate performance status and comorbidity burden, however, may be better characterized as "vulnerable". These patients have subclinical impairments that limit resilience when stressed with intensive therapies. More sensitive assessment strategies are needed to differentiate fit and vulnerable older adults regardless of chronologic age. Research is ongoing to identify tools and approaches, such as geriatric assessment, that can enhance characterization of fitness for AML therapies. This review will highlight available evidence for assessment of fitness among older adults with AML and discuss implications for practice and research.

  17. Impact of Voltage Mapping to Guide Whether to Perform Ablation of the Posterior Wall in Patients With Persistent Atrial Fibrillation.

    PubMed

    Cutler, Michael J; Johnson, Jeremy; Abozguia, Khalid; Rowan, Shane; Lewis, William; Costantini, Otto; Natale, Andrea; Ziv, Ohad

    2016-01-01

    Fibrosis as a substrate for atrial fibrillation (AF) has been shown in numerous preclinical models. Voltage mapping enables in vivo assessment of scar in the left atrium (LA), which can be targeted with catheter ablation. We hypothesized that using the presence or absence of low voltage to guide ablation beyond pulmonary vein antral isolation (PVAI) will improve atrial arrhythmia (AF/AT)-free survival in persistent AF. Single-center retrospective analysis of 2 AF ablation strategies: (1) standard ablation (SA) versus (2) voltage-guided ablation (VGA). PVAI was performed in both groups. With SA, additional lesions beyond PVAI were performed at the discretion of the operator. With VGA, additional lesions to isolate the LA posterior wall were performed if voltage mapping of this region in sinus rhythm showed scar (LA voltage < 0.5 mV). AF-/AT-free endpoint was defined as no sustained AF/AT seen off antiarrhythmic medications after a 2-month postablation blanking period. Seventy-six patients underwent SA and 65 underwent VGA. Patients were well matched for comorbidities, LVEF, and left atrial size. Posterior wall ablation was performed in 57% of patient with SA compared to 42% with VGA. VGA ablation increased 1-year AF-/AT-free survival in patients when compared to SA (80% vs. 57%; P = 0.005). In a multivariate analysis, VGA was the only independent predictor of AF-/AT-free survival (hazard ratio of 0.30; P = 0.002). The presence of LA posterior wall scar may be an important ablation target in persistent AF. A prospective randomized trial is needed to confirm these data. © 2015 Wiley Periodicals, Inc.

  18. 77 FR 33489 - Draft Offender Tracking System Standard

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-06

    ... Tracking System Standard AGENCY: National Institute of Justice. ACTION: Notice of Draft Offender Tracking System Standard, Selection and Application Guide, and Certification Program Requirements. SUMMARY: In an...) A draft standard entitled, ``Offender Tracking System Standard'' (2) a draft companion document...

  19. Ultrasound-guided central venous access using Google Glass.

    PubMed

    Wu, Teresa S; Dameff, Christian J; Tully, Jeffrey L

    2014-12-01

    The use of ultrasound during invasive bedside procedures is quickly becoming the standard of care. Ultrasound machine placement during procedures often requires the practitioner to turn their head during the procedure to view the screen. Such turning has been implicated in unintentional hand movements in novices. Google Glass is a head-mounted computer with a specialized screen capable of projecting images and video into the view of the wearer. Such technology may help decrease unintentional hand movements. Our aim was to evaluate whether or not medical practitioners at various levels of training could use Google Glass to perform an ultrasound-guided procedure, and to explore potential advantages of this technology. Forty participants of varying training levels were randomized into two groups. One group used Google Glass to perform an ultrasound-guided central line. The other group used traditional ultrasound during the procedure. Video recordings of eye and hand movements were analyzed. All participants from both groups were able to complete the procedure without difficulty. Google Glass wearers took longer to perform the procedure at all training levels (medical student year 1 [MS1]: 193 s vs. 77 s, p > 0.5; MS4: 197s vs. 91s, p ≤ 0.05; postgraduate year 1 [PGY1]: 288s vs. 125 s, p > 0.5; PGY3: 151 s vs. 52 s, p ≤ 0.05), and required more needle redirections (MS1: 4.4 vs. 2.0, p > 0.5; MS4: 4.8 vs. 2.8, p > 0.5; PGY1: 4.4 vs. 2.8, p > 0.5; PGY3: 2.0 vs. 1.0, p > 0.5). In this study, it was possible to perform ultrasound-guided procedures with Google Glass. Google Glass wearers, on average, took longer to gain access, and had more needle redirections, but less head movements were noted. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Curriculum Guide for Fashion Merchandising (Fashion Salesperson).

    ERIC Educational Resources Information Center

    Gregory, Margaret R.

    This curriculum guide is designed to help teachers teach a course in fashion merchandising to high school students. The guide contains eight performance-based learning modules, each consisting of one to seven units. Each unit teaches a job-relevant task, and includes performance objectives, performance guides, resources, learning activities,…

  1. IPM Standards for Schools: A Program for Reducing Pest and Pesticide Risks in Schools and Other Sensitive Environments. Version 2.0.

    ERIC Educational Resources Information Center

    Green, Thomas A., Ed.

    This guide presents Integrated Pest Management (IPM) practice standards for educational facilities to help schools become certified in providing effective and safe pest control. The guide is divided into two parts with three modules each for both buildings and grounds. The first module addresses building the IPM foundation to meet all legal…

  2. A Guide for Developing Standard Operating Job Procedures for the Pump Station Process Wastewater Treatment Facility. SOJP No. 3.

    ERIC Educational Resources Information Center

    Perley, Gordon F.

    This is a guide for standard operating job procedures for the pump station process of wastewater treatment plants. Step-by-step instructions are given for pre-start up inspection, start-up procedures, continuous routine operation procedures, and shut-down procedures. A general description of the equipment used in the process is given. Two…

  3. Healthy Water Healthy People Water Quality Educators Guide

    ERIC Educational Resources Information Center

    Project WET Foundation, 2003

    2003-01-01

    This 200-page activity guide for educators of students in grades six through university level raises the awareness and understanding of water quality issues and their relationship to personal, public and environmental health. "Healthy Water Healthy People Water Quality Educators Guide" will help educators address science standards through 25…

  4. Food Buying Guide for Child Nutrition Programs. Revised.

    ERIC Educational Resources Information Center

    Davis, Dorothy W.; And Others

    This guide is based on the latest federal regulations and meal pattern requirements for the National School Lunch and Breakfast Programs. It considers current food production and marketing techniques, packaging methods, grading standards, and changing food habits in the American population. The guide gives average yield information on over 600…

  5. 17 CFR 229.802 - Exchange Act industry guides.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 17 Commodity and Securities Exchanges 2 2010-04-01 2010-04-01 false Exchange Act industry guides. 229.802 Section 229.802 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION STANDARD... AND CONSERVATION ACT OF 1975-REGULATION S-K List of Industry Guides § 229.802 Exchange Act industry...

  6. 17 CFR 229.801 - Securities Act industry guides.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 17 Commodity and Securities Exchanges 2 2013-04-01 2013-04-01 false Securities Act industry guides. 229.801 Section 229.801 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION STANDARD... AND CONSERVATION ACT OF 1975-REGULATION S-K List of Industry Guides § 229.801 Securities Act industry...

  7. 17 CFR 229.802 - Exchange Act industry guides.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 17 Commodity and Securities Exchanges 2 2012-04-01 2012-04-01 false Exchange Act industry guides. 229.802 Section 229.802 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION STANDARD... AND CONSERVATION ACT OF 1975-REGULATION S-K List of Industry Guides § 229.802 Exchange Act industry...

  8. 17 CFR 229.801 - Securities Act industry guides.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 17 Commodity and Securities Exchanges 2 2011-04-01 2011-04-01 false Securities Act industry guides. 229.801 Section 229.801 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION STANDARD... AND CONSERVATION ACT OF 1975-REGULATION S-K List of Industry Guides § 229.801 Securities Act industry...

  9. 17 CFR 229.802 - Exchange Act industry guides.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 17 Commodity and Securities Exchanges 3 2014-04-01 2014-04-01 false Exchange Act industry guides. 229.802 Section 229.802 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION STANDARD... AND CONSERVATION ACT OF 1975-REGULATION S-K List of Industry Guides § 229.802 Exchange Act industry...

  10. 17 CFR 229.802 - Exchange Act industry guides.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 17 Commodity and Securities Exchanges 2 2013-04-01 2013-04-01 false Exchange Act industry guides. 229.802 Section 229.802 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION STANDARD... AND CONSERVATION ACT OF 1975-REGULATION S-K List of Industry Guides § 229.802 Exchange Act industry...

  11. 17 CFR 229.801 - Securities Act industry guides.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 17 Commodity and Securities Exchanges 2 2012-04-01 2012-04-01 false Securities Act industry guides. 229.801 Section 229.801 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION STANDARD... AND CONSERVATION ACT OF 1975-REGULATION S-K List of Industry Guides § 229.801 Securities Act industry...

  12. 17 CFR 229.801 - Securities Act industry guides.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 17 Commodity and Securities Exchanges 3 2014-04-01 2014-04-01 false Securities Act industry guides. 229.801 Section 229.801 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION STANDARD... AND CONSERVATION ACT OF 1975-REGULATION S-K List of Industry Guides § 229.801 Securities Act industry...

  13. 17 CFR 229.802 - Exchange Act industry guides.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 17 Commodity and Securities Exchanges 2 2011-04-01 2011-04-01 false Exchange Act industry guides. 229.802 Section 229.802 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION STANDARD... AND CONSERVATION ACT OF 1975-REGULATION S-K List of Industry Guides § 229.802 Exchange Act industry...

  14. Flight Instructor: Airplane. Written Test Guide.

    ERIC Educational Resources Information Center

    Federal Aviation Administration (DOT), Washington, DC. Flight Standards Service.

    The Flight Standards Service of the Federal Aviation Administration developed the guide to assist applicants who are preparing for the Flight Instructor Certificate with Airplane Rating. The guide contains comprehensive study outlines and a list of recommended study materials and tells how to obtain those publications. It also includes sample test…

  15. Medical Assisting Program Guide.

    ERIC Educational Resources Information Center

    Georgia Univ., Athens. Dept. of Vocational Education.

    This guide presents the standard curriculum for technical institutes in Georgia. The curriculum addresses the minimum competencies for a medical assisting program. The program guide is designed to relate primarily to the development of those skills needed by individuals in the medical assisting field, such as medical law and ethics, typing,…

  16. Cataloging Guide for Instructional Materials Used in Livonia Public Schools Instructional Materials Centers.

    ERIC Educational Resources Information Center

    Livonia Public Schools, MI.

    This working guide for Livonia's Public Schools provides detailed instructions in preparing and handling catalog cards, a supplemental cataloging and classification guide, and typing rules for technical processing. Standard abbreviations are given for making classification entries, and separate cataloging instructions are given for charts,…

  17. Standardized methodology for transfemoral transcatheter aortic valve replacement with the Edwards Sapien XT valve under fluoroscopy guidance.

    PubMed

    Kasel, Albert M; Shivaraju, Anupama; Schneider, Stephan; Krapf, Stephan; Oertel, Frank; Burgdorf, Christof; Ott, Ilka; Sumer, Christian; Kastrati, Adnan; von Scheidt, Wolfgang; Thilo, Christian

    2014-09-01

    To provide a simplified, standardized methodology for a successful transfemoral transcatheter aortic valve replacement (TAVR) procedure with the Sapien XT valve in patients with severe aortic stenosis (AS). TAVR is currently reserved for patients with severe, symptomatic AS who are inoperable or at high operative risk. In many institutions, TAVR is performed under general anesthesia with intubation or with conscious sedation. In addition, many institutions still use transesophageal echo (TEE) during the procedure for aortic root angulations and positioning of the valve prior to implantation. Methods. We enrolled 100 consecutive patients (mean age, 80 ± 7 years; range, 50-94 years; female n=59) with severe symptomatic AS. Annulus measurements were based on computed tomography angiograms. All patients underwent fluoroscopy-guided transfemoral TAVR with little to no sedation and without simultaneous TEE. TAVR was predominantly performed with the use of local and central analgesics; only 36% of our cohort received conscious sedation. Procedural success of TAVR was 99%. Transthoracic echocardiography before discharge excluded aortic regurgitation (AR) >2 in all patients (AR >1; n=6). In-hospital stroke rate was 6%. The vessel closure system was successfully employed in 96%. Major vascular complication rate was 1%. The 30-day mortality was 2%. Fluoroscopy-guided TAVR with the use of just analgesics with or without conscious sedation is safe and effective, and this potentially enables a more time-effective and cost-effective procedure. This paper provides simplified, stepwise guidance on how to perform transfemoral TAVR with the Sapien XT valve.

  18. Intraoperative positioning of the hindfoot with the hindfoot alignment guide: a pilot study.

    PubMed

    Frigg, Arno; Jud, Lukas; Valderrabano, Victor

    2014-01-01

    In a previous study, intraoperative positioning of the hindfoot by visual means resulted in the wrong varus/valgus position by 8 degrees and a relatively large standard deviation of 8 degrees. Thus, new intraoperative means are needed to improve the precision of hindfoot surgery. We therefore sought a hindfoot alignment guide that would be as simple as the alignment guides used in total knee arthroplasty. A novel hindfoot alignment guide (HA guide) has been developed that projects the mechanical axis from the tibia down to the heel. The HA guide enables the positioning of the hindfoot in the desired varus/valgus position and in plantigrade position in the lateral plane. The HA guide was used intraoperatively from May through November 2011 in 11 complex patients with simultaneous correction of the supramalleolar, tibiotalar, and inframalleolar alignment. Pre- and postoperative Saltzman views were taken and the position was measured. The HA guide significantly improved the intraoperative positioning compared with visual means: The accuracy with the HA guide was 4.5 ± 5.1 degrees (mean ± standard deviation) and without the HA guide 9.4 ± 5.5 degrees (P < .05). In 7 of 11 patients, the preoperative plan was changed because of the HA guide (2 avoided osteotomies, 5 additional osteotomies). The HA guide helped to position the hindfoot intraoperatively with greater precision than visual means. The HA guide was especially useful for multilevel corrections in which the need for and the amount of a simultaneous osteotomy had to be evaluated intraoperatively. Level IV, case series.

  19. Moon Munchies: Human Exploration Project Engineering Design Challenge--A Standards-Based Elementary School Model Unit Guide--Design, Build, and Evaluate (Lessons 1-6). Engineering By Design: Advancing Technological Literacy--A Standards-Based Program Series. EP-2007-08-92-MSFC

    ERIC Educational Resources Information Center

    Weaver, Kim M.

    2005-01-01

    In this unit, elementary students design and build a lunar plant growth chamber using the Engineering Design Process. The purpose of the unit is to help students understand and apply the design process as it relates to plant growth on the moon. This guide includes six lessons, which meet a number of national standards and benchmarks in…

  20. BTS statistical standards manual

    DOT National Transportation Integrated Search

    2005-10-01

    The Bureau of Transportation Statistics (BTS), like other federal statistical agencies, establishes professional standards to guide the methods and procedures for the collection, processing, storage, and presentation of statistical data. Standards an...

  1. Biopsy of Liver Target Lesions under Contrast-Enhanced Ultrasound Guidance - A Multi-Center Study.

    PubMed

    Francica, Giampiero; Meloni, Maria Franca; de Sio, Ilario; Terracciano, Fulvia; Caturelli, Eugenio; Riccardi, Laura; Roselli, Paola; Iadevaia, Maddalena Diana; Scaglione, Mariano; Lenna, Giovanni; Chiang, Jason; Pompili, Maurizio

    2017-12-12

    Purpose  To retrospectively characterize the prevalence and impact of contrast-enhanced ultrasound (CEUS) as a guidance technique for the biopsy of liver target lesions (LTLs) at six interventional ultrasound centers. Materials and Methods  The six participating centers retrospectively selected all patients in whom biopsy needles were positioned in LTLs during CEUS. The prevalence of CEUS-guided biopsies at each center between 2005 and 2016, contrast agent consumption, procedure indications, diagnostic yield and complications were assessed. Informed consent was obtained for all patients. Results  CEUS-guided biopsy of LTLs was carried out in 103 patients (68 M/35 F, median age: 69 yrs) with 103 liver target lesions (median size: 20 mm) using cutting needles (18 - 20 g) in 94 cases (91.2 %). CEUS-guided biopsy represented 2.6 % (range: 0.8 - 7.7 %) of 3818 biopsies on LTLs carried out at the participating centers. Indications to CEUS-guided biopsy were: a target lesion not visible on non-enhanced US (27.2 %), improvement of conspicuity of the target (33 %), choice of non-necrotic area inside the target (39.8 %). 26 patients (25.2 %) had a previously non-diagnostic cyto-histological exam. The diagnostic accuracy of the technique was 99 %. No major complications followed infusion of contrast agent or biopsy performance. Conclusion  The indications for CEUS-guided biopsy for LTLs are limited, but CEUS can be useful in challenging clinical scenarios, e. g. poorly visualized or invisible lesions or sampling of non-necrotic areas in the target lesions. There is also a potential advantage in using CEUS to guide repeat biopsies after unsuccessful sampling performed using the standard ultrasound technique. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Facilitated versus self-guided training of non-ophthalmologists for grading pre-plus and plus disease using fundus images for retinopathy of prematurity screening

    PubMed Central

    Raufi, Nikolas N.; Morris, Caleb K.; Freedman, Sharon F.; Wallace, David K.; Prakalapakorn, S. Grace

    2016-01-01

    Purpose Retinopathy of prematurity (ROP) is an important cause of preventable blindness; barriers to screening necessitate novel approaches. While trained non-ophthalmologists can accurately grade retinal images for ROP, effective training protocols are not established. This study compares the effectiveness of facilitated versus self-guided training of non-ophthalmologists for grading retinal images for pre-plus or plus disease in ROP. Methods Forty-eight undergraduate and graduate students were trained to grade retinal images for the presence of pre-plus or plus disease. Students were randomly assigned to one of two training protocols. Both utilized identical electronic slideshows; one guided by an in-person facilitator, and the other was self-guided. After completing their respective training, students proficient in grading pre-plus and plus disease graded images in a telemedicine screening scenario. Accuracy of grading was compared to the reference standard of clinical examination. Results 83% (40/48) of trained students (91% in the facilitated vs. 77% in the self-guided group, p=0.26) were proficient and qualified to grade the ROP telemedicine screening scenario. Median accuracy for grading normal, pre-plus or plus disease was 69% (70% in the facilitated vs. 68% in the self-guided group, p=0.91). When considering the designation of pre-plus or plus disease by graders as a screening test for detecting plus disease (confirmed on clinical exam), the median sensitivity and specificity of all students was 95% and 64%, respectively. Conclusions Both facilitated- and self-guided teaching protocols yielded similar performance in ROP image grading for pre-plus or plus disease. Self-guided training protocols may be adequate to train non-ophthalmologists to grade retinal images for pre-plus and plus disease with high sensitivity. PMID:27224953

  3. 42 CFR 423.160 - Standards for electronic prescribing.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Council for Prescription Drug Programs Prescriber/Pharmacist Interface SCRIPT Standard, Implementation... National Council for Prescription Drug Programs Prescriber/Pharmacist Interface SCRIPT Standard... Prescriber/Pharmacist Interface SCRIPT Standard, Implementation Guide Version 8, Release 1 (Version 8.1...

  4. 42 CFR 423.160 - Standards for electronic prescribing.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... National Council for Prescription Drug Programs Prescriber/Pharmacist Interface SCRIPT Standard... National Council for Prescription Drug Programs Prescriber/Pharmacist Interface SCRIPT Standard... Prescriber/Pharmacist Interface SCRIPT Standard, Implementation Guide Version 8, Release 1 (Version 8.1...

  5. 42 CFR 423.160 - Standards for electronic prescribing.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... National Council for Prescription Drug Programs Prescriber/Pharmacist Interface SCRIPT Standard... National Council for Prescription Drug Programs Prescriber/Pharmacist Interface SCRIPT Standard... Prescriber/Pharmacist Interface SCRIPT Standard, Implementation Guide Version 8, Release 1 (Version 8.1...

  6. Writing Material Safely Data Sheets Using the ANSI Standard.

    ERIC Educational Resources Information Center

    Croft, Suzanne D.

    1996-01-01

    Presents a history of the ANSI (American National Standards Institute) standard for preparation of Material Safety Data Sheets (MSDS), and provides a section-by-section guide to preparing MSDSs that comply with the standard. (SR)

  7. Phase I/II prospective trial of cancer-specific imaging using ultrasound spectrum analysis tissue-type imaging to guide dose-painting prostate brachytherapy.

    PubMed

    Ennis, Ronald D; Quinn, S Aidan; Trichter, Frieda; Ryemon, Shannon; Jain, Anudh; Saigal, Kunal; Chandrashekhar, Sarayu; Romas, Nicholas A; Feleppa, Ernest J

    2015-01-01

    To assess the technical feasibility, toxicity, dosimetry, and preliminary efficacy of dose-painting brachytherapy guided by ultrasound spectrum analysis tissue-type imaging (TTI) in low-risk, localized prostate cancer. Fourteen men with prostate cancer who were candidates for brachytherapy as sole treatment were prospectively enrolled. Treatment planning goal was to escalate the tumor dose to 200% with a modest de-escalation of dose to remaining prostate compared with our standard. Primary end points included technical feasibility of TTI-guided brachytherapy and equivalent or better toxicity compared with standard brachytherapy. Secondary end points included dose escalation to tumor regions and de-escalated dose to nontumor regions on the preimplant plan, negative prostate biopsy at 2 years, and freedom from biochemical failure. Thirteen of fourteen men successfully completed the TTI-guided brachytherapy procedure for a feasibility rate of 93%. A software malfunction resulted in switching one patient from TTI-guided to standard brachytherapy. An average of 2.7 foci per patient was demonstrated and treated with an escalated dose. Dosimetric goals on preplan were achieved. One patient expired from unrelated causes 65 days after brachytherapy. Toxicity was at least as low as standard brachytherapy. Two-year prostate biopsies were obtained from six men; five (83%) were definitively negative, one showed evidence of disease with treatment effect, and none were positive. No patients experienced biochemical recurrence after a median followup of 31.5 (24-52) months. We have demonstrated that TTI-guided dose-painting prostate brachytherapy is technically feasible and results in clinical outcomes that are encouraging in terms of low toxicity and successful biochemical disease control. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  8. Procalcitonin-guided antibiotic therapy in patients with fever in a general emergency department population: a multicenter noninferiority randomized clinical trial (HiTEMP study).

    PubMed

    van der Does, Yuri; Limper, Maarten; Jie, Kim E; Schuit, Stephanie C E; Jansen, Henry; Pernot, Niki; van Rosmalen, Joost; Poley, Marten J; Ramakers, Christian; Patka, Peter; van Gorp, Eric C M; Rood, Pleunie P M

    2018-06-02

    Overuse of broad-spectrum antibiotics in emergency departments(EDs) results in antibiotic resistance. We determined if procalcitonin(PCT)-guided therapy can be used to reduce antibiotic regimens in EDs by investigating efficacy, safety and accuracy. This was a noninferiority multicenter randomized clinical trial, performed in two Dutch hospitals. Adult patients with fever ≥38.2°C(100.8°F) in triage were randomized between standard diagnostic workup(control group) and PCT-guided therapy, defined as standard workup with addition of one single PCT measurement. Treatment algorithm encouraged withholding antibiotic regimens with PCT<0.5μg/L, and starting antibiotic regimens PCT≥0.5μg/L. Exclusion criteria were immunocompromised conditions, pregnancy, moribund patients, patients <72h after surgery or requiring primary surgical intervention. Primary outcomes were efficacy, defined as number of prescribed antibiotic regimens; safety, defined as combined-safety-endpoint(CSE) consisting of 30-days mortality, intensive-care unit admission, ED-return-visit within 2 weeks; accuracy, defined as sensitivity, apecificity and area-under-the-curve(AUC) of PCT for bacterial infections. Noninferiority margin for safety outcome was 7.5%. Between August 2014 and January 2017, 551 patients were included. In the PCT-guided group(n=275) 200(73%)patients were prescribed antibiotic regimens, in the control group(n=276) 212(77%)(p=0.28). There was no significant difference in CSE between the PCT-guided group, 29(11%), and control group, 46(16%)(p=0.16), with a noninferiority margin of 0.46%(n=526). AUC for confirmed bacterial infections for PCT was 0.681(95%CI0.633-0.730), for CRP 0.619(95%CI 0.569-0.669).: CONCLUSIONS.: PCT-guided therapy was noninferior in terms of safety, but did not reduce prescription of antibiotic regimens in an ED population with fever. In this heterogeneous population, the accuracy of PCT in diagnosing bacterial infections was poor. TRIAL REGISTRATION IN NETHERLANDS TRIAL REGISTER: http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=4949. Copyright © 2018. Published by Elsevier Ltd.

  9. IS0 9000 Implementation and Assessment: A Guide to Developing and Evaluating Quality Management Systems

    NASA Technical Reports Server (NTRS)

    Navarro, Robert J.; Grimm, Barry

    1996-01-01

    The agency has developed this reference publication to aid NASA organizations and their suppliers in the transition to IS0 9000. This guide focuses on the standard s intent, clarifies its requirements, offers implementation examples and highlights interrelated areas. It can assist anyone developing or evaluating NASA or supplier quality management systems. The IS0 9000 standards contain the basic elements for managing those processes that affect an organization's ability to consistently meet customer requirements. IS0 9000 was developed through the International Organization for Standardization and has been adopted as the US. national standard. These standards define a flexible foundation for customer focused process measurement, management and improvement that is the hallmark of world class enterprises.

  10. NASA Educational Product Development and Post-Secondary Program Assessment Planning

    NASA Technical Reports Server (NTRS)

    Salmons, Phyllis A.

    1999-01-01

    Producing "value-added students" involves proactively addressing how successfully students develop their skills, knowledge, and personal, social, and ethical growth due to their association with a program. NASA programs for higher education can certainly be responsive in aiding the academic community strive for quality in terms of "valueadded" students. By identifying essential characteristics of exemplary assessment practices, the standards developed by accrediting agencies serve as guides for developing quality practices and policies. Such a process is an effective tool for communicating the expectations of the educational components of a program to all concerned with the program and its expected results. When standards are connected to student performance, they provide a very compelling argument for refocusing the definition of quality in higher education. By linking standards and performance, student learning and development becomes the starting point for examining program quality. If the multiple stakeholders - faculty, peers, the professional community, addressed assessment issues, then accreditation can be a link among various constituencies, the parties can better understand the needs of each other and develop the necessary trust needed for understanding and support.

  11. Contracting Deployment Customer Guide.

    DTIC Science & Technology

    1996-12-01

    functional managers from the major commands expressed the need to develop a Customer Guide for contingency deployments which would standardize, simplify, and...streamline the support our Contingency Contracting Officers (CCOs) provide to our customers .

  12. Image-guided tumor ablation: standardization of terminology and reporting criteria.

    PubMed

    Goldberg, S Nahum; Grassi, Clement J; Cardella, John F; Charboneau, J William; Dodd, Gerald D; Dupuy, Damian E; Gervais, Debra A; Gillams, Alice R; Kane, Robert A; Lee, Fred T; Livraghi, Tito; McGahan, John; Phillips, David A; Rhim, Hyunchul; Silverman, Stuart G; Solbiati, Luigi; Vogl, Thomas J; Wood, Bradford J; Vedantham, Suresh; Sacks, David

    2009-07-01

    The field of interventional oncology with use of image-guided tumor ablation requires standardization of terminology and reporting criteria to facilitate effective communication of ideas and appropriate comparison between treatments that use different technologies, such as chemical (ethanol or acetic acid) ablation, and thermal therapies, such as radiofrequency (RF), laser, microwave, ultrasound, and cryoablation. This document provides a framework that will hopefully facilitate the clearest communication between investigators and will provide the greatest flexibility in comparison between the many new, exciting, and emerging technologies. An appropriate vehicle for reporting the various aspects of image-guided ablation therapy, including classification of therapies and procedure terms, appropriate descriptors of imaging guidance, and terminology to define imaging and pathologic findings, are outlined. Methods for standardizing the reporting of follow-up findings and complications and other important aspects that require attention when reporting clinical results are addressed. It is the group's intention that adherence to the recommendations will facilitate achievement of the group's main objective: improved precision and communication in this field that lead to more accurate comparison of technologies and results and, ultimately, to improved patient outcomes. The intent of this standardization of terminology is to provide an appropriate vehicle for reporting the various aspects of image-guided ablation therapy.

  13. AMERICAN STANDARD GUIDE FOR SCHOOL LIGHTING.

    ERIC Educational Resources Information Center

    Illuminating Engineering Society, New York, NY.

    THIS IS A GUIDE FOR SCHOOL LIGHTING, DESIGNED FOR EDUCATORS AS WELL AS ARCHITECTS. IT MAKES USE OF RECENT RESEARCH, NOTABLY THE BLACKWELL REPORT ON EVALUATION OF VISUAL TASKS. THE GUIDE BEGINS WITH AN OVERVIEW OF CHANGING GOALS AND NEEDS OF SCHOOL LIGHTING, AND A TABULATION OF COMMON CLASSROOM VISUAL TASKS THAT REQUIRE VARIATIONS IN LIGHTING.…

  14. Earth/Space Science Course No. 2001310. [Student Guide and] Teacher's Guide.

    ERIC Educational Resources Information Center

    Atkinson, Missy

    These documents contain instructional materials for the Earth/Space Science curriculum designed by the Florida Department of Education. The student guide is adapted for students with disabilities or diverse learning needs. The content of Parallel Alternative Strategies for Students (PASS) differs from standard textbooks with its simplified text,…

  15. Dental Shade Guide Variability for Hues B, C, and D Using Cross-Polarized Photography.

    PubMed

    Sampaio, Camila S; Gurrea, Jon; Gurrea, Marta; Bruguera, August; Atria, Pablo J; Janal, Malvin; Bonfante, Estevam A; Coelho, Paulo G; Hirata, Ronaldo

    2018-04-20

    This study evaluated the color variability of hues B, C, and D between the VITA Classical shade guide (Vita Zahnfabrik) and four other VITA-coded ceramic shade guides using a digital camera (Canon EOS 60D) and computer software (Adobe Photoshop CC). A cross-polarizing filter was used to standardize external light sources influencing color match. A total of 275 pictures were taken, 5 per shade tab, for 11 shades (B1, B2, B3, B4, C1, C2, C3, C4, D2, D3, and D4), from the following shade guides: VITA Classical (control); IPS e.max Ceram (Ivoclar Vivadent); IPS d.SIGN (Ivoclar Vivadent); Initial ZI (GC); and Creation CC (Creation Willi Geller). Pictures were evaluated using Adobe Photoshop CC for standardization of hue, chroma, and value between shade tabs. The VITA-coded shade guides evaluated here showed an overall unmatched shade in all their tabs when compared to the control, suggesting that shade selection should be made with the corresponding manufacturer guide of the ceramic intended for the final restoration.

  16. Laser-only Adaptive Optics Achieves Significant Image Quality Gains Compared to Seeing-limited Observations over the Entire Sky

    NASA Astrophysics Data System (ADS)

    Howard, Ward S.; Law, Nicholas M.; Ziegler, Carl A.; Baranec, Christoph; Riddle, Reed

    2018-02-01

    Adaptive optics laser guide-star systems perform atmospheric correction of stellar wavefronts in two parts: stellar tip-tilt and high-spatial-order laser correction. The requirement of a sufficiently bright guide star in the field-of-view to correct tip-tilt limits sky coverage. In this paper, we show an improvement to effective seeing without the need for nearby bright stars, enabling full sky coverage by performing only laser-assisted wavefront correction. We used Robo-AO, the first robotic AO system, to comprehensively demonstrate this laser-only correction. We analyze observations from four years of efficient robotic operation covering 15000 targets and 42000 observations, each realizing different seeing conditions. Using an autoguider (or a post-processing software equivalent) and the laser to improve effective seeing independent of the brightness of a target, Robo-AO observations show a 39% ± 19% improvement to effective FWHM, without any tip-tilt correction. We also demonstrate that 50% encircled energy performance without tip-tilt correction remains comparable to diffraction-limited, standard Robo-AO performance. Faint-target science programs primarily limited by 50% encircled energy (e.g., those employing integral field spectrographs placed behind the AO system) may see significant benefits to sky coverage from employing laser-only AO.

  17. A Catalog of Tasks, Performance Objectives, Performance Guides, Tools, and Equipment, Homemaker Human Development.

    ERIC Educational Resources Information Center

    Watkins, Betty; And Others

    This catalog was designed to provide performance objectives and performance guides associated with current occupational information relating to the job of homemaker. The performance objectives and guides were developed following a literature review and a survey of random samples of homemakers in the five participating states (Alabama, Florida,…

  18. Identifying and quantifying heterogeneity in high content analysis: application of heterogeneity indices to drug discovery.

    PubMed

    Gough, Albert H; Chen, Ning; Shun, Tong Ying; Lezon, Timothy R; Boltz, Robert C; Reese, Celeste E; Wagner, Jacob; Vernetti, Lawrence A; Grandis, Jennifer R; Lee, Adrian V; Stern, Andrew M; Schurdak, Mark E; Taylor, D Lansing

    2014-01-01

    One of the greatest challenges in biomedical research, drug discovery and diagnostics is understanding how seemingly identical cells can respond differently to perturbagens including drugs for disease treatment. Although heterogeneity has become an accepted characteristic of a population of cells, in drug discovery it is not routinely evaluated or reported. The standard practice for cell-based, high content assays has been to assume a normal distribution and to report a well-to-well average value with a standard deviation. To address this important issue we sought to define a method that could be readily implemented to identify, quantify and characterize heterogeneity in cellular and small organism assays to guide decisions during drug discovery and experimental cell/tissue profiling. Our study revealed that heterogeneity can be effectively identified and quantified with three indices that indicate diversity, non-normality and percent outliers. The indices were evaluated using the induction and inhibition of STAT3 activation in five cell lines where the systems response including sample preparation and instrument performance were well characterized and controlled. These heterogeneity indices provide a standardized method that can easily be integrated into small and large scale screening or profiling projects to guide interpretation of the biology, as well as the development of therapeutics and diagnostics. Understanding the heterogeneity in the response to perturbagens will become a critical factor in designing strategies for the development of therapeutics including targeted polypharmacology.

  19. Quantifying the measurement uncertainty of results from environmental analytical methods.

    PubMed

    Moser, J; Wegscheider, W; Sperka-Gottlieb, C

    2001-07-01

    The Eurachem-CITAC Guide Quantifying Uncertainty in Analytical Measurement was put into practice in a public laboratory devoted to environmental analytical measurements. In doing so due regard was given to the provisions of ISO 17025 and an attempt was made to base the entire estimation of measurement uncertainty on available data from the literature or from previously performed validation studies. Most environmental analytical procedures laid down in national or international standards are the result of cooperative efforts and put into effect as part of a compromise between all parties involved, public and private, that also encompasses environmental standards and statutory limits. Central to many procedures is the focus on the measurement of environmental effects rather than on individual chemical species. In this situation it is particularly important to understand the measurement process well enough to produce a realistic uncertainty statement. Environmental analytical methods will be examined as far as necessary, but reference will also be made to analytical methods in general and to physical measurement methods where appropriate. This paper describes ways and means of quantifying uncertainty for frequently practised methods of environmental analysis. It will be shown that operationally defined measurands are no obstacle to the estimation process as described in the Eurachem/CITAC Guide if it is accepted that the dominating component of uncertainty comes from the actual practice of the method as a reproducibility standard deviation.

  20. Guide to conducting tinnitus retraining therapy initial and follow-up interviews.

    PubMed

    Henry, James A; Jastreboff, Margaret M; Jastreboff, Pawel J; Schechter, Martin A; Fausti, Stephen A

    2003-01-01

    Tinnitus Retraining Therapy (TRT) is a structured method of tinnitus treatment that has been performed since 1990. The TRT Initial Interview form was developed to guide clinicians in obtaining essential information from patients that would specify treatment needs. The TRT Follow-up Interview form is similar to the initial interview form and is designed to evaluate outcomes of treatment. The clinician administers these forms verbally. The forms have been used in a highly abbreviated format with the potential for inconsistent interview administration between examiners. This project was to expand the forms to provide specific wording for each question. The expanded forms are presented in this article, and the intent of each question is explained. Standardized administration of these interview forms will facilitate greater uniformity in the initial evaluation and outcomes analyses of patients treated with TRT.

  1. The PrePex device is unlikely to achieve cost-savings compared to the forceps-guided method in male circumcision programs in sub-Saharan Africa.

    PubMed

    Obiero, Walter; Young, Marisa R; Bailey, Robert C

    2013-01-01

    Male circumcision (MC) reduces the risk of heterosexual HIV acquisition in men by approximately 60%. MC programs for HIV prevention are currently being scaled-up in fourteen countries in sub-Saharan Africa. The current standard surgical technique for MC in many sub-Saharan African countries is the forceps-guided male circumcision (FGMC) method. The PrePex male circumcision (PMC) method could replace FGMC and potentially reduce MC programming costs. We compared the potential costs of introducing the PrePex device into MC programming to the cost of the forceps-guided method. Data were obtained from the Nyanza Reproductive Health Society (NRHS), an MC service delivery organization in Kenya, and from the Kenya Ministry of Health. Analyses are based on 48,265 MC procedures performed in four Districts in western Kenya from 2009 through 2011. Data were entered into the WHO/UNAIDS Decision Makers Program Planning Tool. The tool assesses direct and indirect costs of MC programming. Various sensitivity analyses were performed. Costs were discounted at an annual rate of 6% and are presented in United States Dollars. Not including the costs of the PrePex device or referral costs for men with phimosis/tight foreskin, the costs of one MC surgery were $44.54-$49.02 and $54.52-$55.29 for PMC and FGMC, respectively. The PrePex device is unlikely to result in significant cost-savings in comparison to the forceps-guided method. MC programmers should target other aspects of the male circumcision minimum package for improved cost efficiency.

  2. Efficacy of video-guided laryngoscope in airway management skills of medical students.

    PubMed

    Peirovifar, Ali; Mahmoodpoor, Ata; Golzari, Samad Ej; Soleimanpour, Hassan; Eslampour, Yashar; Fattahi, Vahid

    2014-10-01

    Video-guided laryngoscopy, though unproven in achieving better success rates of laryngoscopy outcome and intubation, seems to provide better glottic visualization compared with direct laryngoscopy. The objective of this study was to compare the efficacy of video-guided laryngoscope (VGL) in the airway management skills of medical students. Medical students throughout their anesthesiology rotations were enrolled in this study. All students received standard training in the airway management during their course and were randomly allocated into two 20 person groups. In Group D, airway management was performed by direct laryngoscopy via Macintosh blade and in Group G intubation was performed via VGL. Time to intubation, number of laryngoscopy attempts and success rate were noted. Successful intubation was considered as the primary outcome. All data were analyzed using SPSS 16 software. Chi-square and Fisher's exact test were used for analysis of categorical variables. For analyzing continuous variables independent t-test was used. P < 0.05 was considered as statistically significant. Number of laryngoscopy attempts was less in Group G in comparison to Group D; this, however, was statistically insignificant (P: 0.18). Time to intubation was significantly less in Group G as compared to Group D (P: 0.02). Successful intubation in Group G was less frequently when compared to Group D (P: 0.66). Need for attending intervention, esophageal intubation and hypoxemic events during laryngoscopy were less in Group G; this, however, was statistically insignificant. The use of video-guided laryngoscopy improved the first attempt success rate, time to intubation, laryngoscopy attempts and airway management ability of medical students compared to direct laryngoscopy.

  3. 77 FR 205 - Federal Acquisition Regulation; Federal Acquisition Circular 2005-55; Small Entity Compliance Guide

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-03

    ... System. VI Updated Financial 2010-005 Chambers. Accounting Standards Board Accounting References. VII... Financial Accounting Standards Board Accounting References (FAR Case 2010-005) This final rule amends the... authoritative accounting standards owing to the Financial Accounting Standards Board's Accounting Standards...

  4. Evaluation of a Modified User Guide for Hearing Aid Management.

    PubMed

    Caposecco, Andrea; Hickson, Louise; Meyer, Carly; Khan, Asaduzzaman

    2016-01-01

    This study investigated if a hearing aid user guide modified using best practice principles for health literacy resulted in superior ability to perform hearing aid management tasks, compared with the user guide in the original form. This research utilized a two-arm study design to compare the original manufacturer's user guide with a modified user guide for the same hearing aid--an Oticon Acto behind-the-ear aid with an open dome. The modified user guide had a lower reading grade level (4.2 versus 10.5), used a larger font size, included more graphics, and had less technical information. Eighty-nine adults ages 55 years and over were included in the study; none had experience with hearing aid use or management. Participants were randomly assigned either the modified guide (n = 47) or the original guide (n = 42). All participants were administered the Hearing Aid Management test, designed for this study, which assessed their ability to perform seven management tasks (e.g., change battery) with their assigned user guide. The regression analysis indicated that the type of user guide was significantly associated with performance on the Hearing Aid Management test, adjusting for 11 potential covariates. In addition, participants assigned the modified guide required significantly fewer prompts to perform tasks and were significantly more likely to perform four of the seven tasks without the need for prompts. The median time taken by those assigned the modified guide was also significantly shorter for three of the tasks. Other variables associated with performance on the Hearing Aid Management test were health literacy level, finger dexterity, and age. Findings indicate that the need to design hearing aid user guides in line with best practice principles of health literacy as a means of facilitating improved hearing aid management in older adults.

  5. EPA Metadata Style Guide Keywords and EPA Organization Names

    EPA Pesticide Factsheets

    The following keywords and EPA organization names listed below, along with EPA’s Metadata Style Guide, are intended to provide suggestions and guidance to assist with the standardization of metadata records.

  6. Standards and guidelines for biopolymers in tissue-engineered medical products: ASTM alginate and chitosan standard guides. American Society for Testing and Materials.

    PubMed

    Dornish, M; Kaplan, D; Skaugrud, O

    2001-11-01

    The American Society for Testing and Materials (ASTM) is making a concerted effort to establish standards and guidelines for the entire field of tissue-engineered medical products (TEMPS). Safety, consistency, and functionality of biomaterials used as matrices, scaffolds, and immobilizing agents in TEMPS are a concern. Therefore, the ASTM has established a number of task groups to produce standards and guidelines for such biomaterials. Alginate is a naturally occurring biomaterial used for immobilizing living cells to form an artificial organ, such as encapsulated pancreatic islets. In order to aid in successful clinical applications and to help expedite regulatory approval, the alginate used must be fully documented. The ASTM alginate guide gives information on selection of testing methodologies and safety criteria. Critical parameters such as monomer content, molecular weight, and viscosity, in addition to more general parameters, such as dry matter content, heavy metal content, bioburden, and endotoxin content are described in the ASTM document. In a like manner, the characterization parameters for chitosan, a bioadhesive polycationic polysaccharide, are described in a separate guide. For chitosan, the degree of deacetylation is of critical importance. Control of protein content and, hence, potential for hypersensitivity, endotoxin content, and total bioburden are important in chitosan preparations for TEMPS. Together these two guides represent part of the effort on behalf of the ASTM and other interested parties to ensure quality and standardization in TEMPS.

  7. DOE interpretations Guide to OSH standards. Update to the Guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-03-31

    Reflecting Secretary O`Leary`s focus on occupational safety and health, the Office of Occupational Safety is pleased to provide you with the latest update to the DOE Interpretations Guide to OSH Standards. This Guide was developed in cooperation with the Occupational Safety and Health Administration, which continued its support during this last revision by facilitating access to the interpretations found on the OSHA Computerized Information System (OCIS). This March 31, 1994 update contains 123 formal interpretation letters written OSHA. As a result of the unique requests received by the 1-800 Response Line, this update also contains 38 interpretations developed by DOE.more » This new occupational safety and health information adds still more important guidance to the four volume reference set that you presently have in your possession.« less

  8. DOE interpretations Guide to OSH standards. Update to the Guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-03-31

    Reflecting Secretary O`Leary`s focus on occupational safety and health, the Office of Occupational Safety is pleased to provide you with the latest update to the DOE Interpretations Guide to OSH Standards. This Guide was developed in cooperation with the Occupational Safety and Health Administration, which continued it`s support during this last revision by facilitating access to the interpretations found on the OSHA Computerized Information System (OCIS). This March 31, 1994 update contains 123 formal in letter written by OSHA. As a result of the unique requests received by the 1-800 Response Line, this update also contains 38 interpretations developed bymore » DOE. This new occupational safety and health information adds still more important guidance to the four volume reference set that you presently have in your possession.« less

  9. Technical Support Document: The Development of the Advanced Energy Design Guide for Highway Lodging Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang, Wei; Jarnagin, Ronald E.; Gowri, Krishnan

    2008-09-30

    This Technical Support Document (TSD) describes the process and methodology for development of the Advanced Energy Design Guide for Highway Lodgings (AEDG-HL or the Guide), a design guidance document intended to provide recommendations for achieving 30% energy savings in highway lodging properties over levels contained in ANSI/ASHRAE/IESNA Standard 90.1-1999, Energy Standard for Buildings Except Low-Rise Residential Buildings. The AEDG-HL is the fifth in a series of guides being developed by a partnership of organizations, including the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (ASHRAE), the American Institute of Architects (AIA), the Illuminating Engineering Society of North America (IESNA),more » the United States Green Buildings Council (USGBC), and the U.S. Department of Energy (DOE).« less

  10. GASB 35 Implementation Guide: Questions and Answers for Public Colleges and Universities Using Business Type Activity (BTA) Reporting. A Supplement to GASB's Implementation Guide for Statement 34

    ERIC Educational Resources Information Center

    National Association of College and University Business Officers (NJ1), 2001

    2001-01-01

    This guide was prepared for public institution business officers as a supplement to the "Guide to Implementation of GASB Statement 54 on Basic Financial Statements--and Management's Discussion and Analysis--for State and Local Governments, published in April 2000 by the Governmental Accounting Standards Board (GASB) on GASB Statements 34 and 35.…

  11. Comparison between audio-only and audiovisual biofeedback for regulating patients' respiration during four-dimensional radiotherapy.

    PubMed

    Yu, Jesang; Choi, Ji Hoon; Ma, Sun Young; Jeung, Tae Sig; Lim, Sangwook

    2015-09-01

    To compare audio-only biofeedback to conventional audiovisual biofeedback for regulating patients' respiration during four-dimensional radiotherapy, limiting damage to healthy surrounding tissues caused by organ movement. Six healthy volunteers were assisted by audiovisual or audio-only biofeedback systems to regulate their respirations. Volunteers breathed through a mask developed for this study by following computer-generated guiding curves displayed on a screen, combined with instructional sounds. They then performed breathing following instructional sounds only. The guiding signals and the volunteers' respiratory signals were logged at 20 samples per second. The standard deviations between the guiding and respiratory curves for the audiovisual and audio-only biofeedback systems were 21.55% and 23.19%, respectively; the average correlation coefficients were 0.9778 and 0.9756, respectively. The regularities between audiovisual and audio-only biofeedback for six volunteers' respirations were same statistically from the paired t-test. The difference between the audiovisual and audio-only biofeedback methods was not significant. Audio-only biofeedback has many advantages, as patients do not require a mask and can quickly adapt to this method in the clinic.

  12. New procedures of ergonomics design in a large oil company.

    PubMed

    Alhadeff, Cynthia Mossé; Silva, Rosana Fernandes da; Reis, Márcia Sales dos

    2012-01-01

    This study presents the challenge involved in the negotiation and construction of a standard process in a major petroleum company that has the purpose of guiding the implementation of ergonomic studies in the development of projects, systemising the implementation of ergonomics design. The standard was created by a multi-disciplinary working group consisting of specialists in ergonomics, who work in a number of different areas of the company. The objective was to guide "how to" undertake ergonomics in all projects, taking into consideration the development of the ergonomic appraisals of work. It also established that all the process, in each project phase, should be accompanied by a specialist in ergonomics. This process as an innovation in the conception of projects in this company, signals a change of culture, and, for this reason requires broad dissemination throughout the several company leadership levels, and training of professionals in projects of ergonomics design. An implementation plan was also prepared and approved by the corporate governance, complementing the proposed challenge. In this way, this major oil company will implement new procedures of ergonomics design to promote health, safety, and wellbeing of the workforce, besides improving the performance and reliability of its systems and processes.

  13. Do Latin American scientific journals follow dual-use review policies?

    PubMed

    Valles, Edith Gladys; Bernacchi, Adriana Silvina

    2014-01-01

    During the past decade, a number of journals have implemented dual-use policies in order to analyze whether the papers submitted for publication could raise concern because of the potential for misuse of their content. In this context, an analysis was performed on Latin American scientific journals to examine whether they apply formal written dual-use review policies and whether they inform their authors and reviewers about potentially sensitive issues in this area, as other international journals do. Peer-reviewed life sciences journals indexed in Latindex from Brazil, Mexico, Argentina, and Chile were analyzed. The Guide for Authors and the Instructions to Referees of 216 journals included in the Latindex catalogue (which means that they meet the best quality standards of the Latindex system) were screened for biosecurity-related information using the keywords biosecurity, biological weapons, and dual-use research of concern. Results showed that the screened publications had a total lack of dual-use review policies, even though some of them pointed out ethical behaviors to be followed related to authorship, plagiarism, simultaneous submission, research results misappropriation, ethical principles for medical research involving human subjects, guiding principles for the care and use of animals in research, research standard violations, and reviewer bias, among others.

  14. Elementary and Secondary Education Property Accounting. A Handbook of Standard Terminology and a Guide for Classifying Information About Education Property. State Educational Records and Reports Series: Handbook III, Revised 1977.

    ERIC Educational Resources Information Center

    Davis (Robert) Associates, Inc., Atlanta, GA.

    The purposes of this handbook are to provide a comprehensive guide to standard terminology relating to property (sites, buildings, and equipment) used in education, a list of suggested data items useful in describing property, general data items useful in describing property, and general guidelines that can assist the reader in understanding and…

  15. Migration in the shearing sheet and estimates for young open cluster migration

    NASA Astrophysics Data System (ADS)

    Quillen, Alice C.; Nolting, Eric; Minchev, Ivan; De Silva, Gayandhi; Chiappini, Cristina

    2018-04-01

    Using tracer particles embedded in self-gravitating shearing sheet N-body simulations, we investigate the distance in guiding centre radius that stars or star clusters can migrate in a few orbital periods. The standard deviations of guiding centre distributions and maximum migration distances depend on the Toomre or critical wavelength and the contrast in mass surface density caused by spiral structure. Comparison between our simulations and estimated guiding radii for a few young supersolar metallicity open clusters, including NGC 6583, suggests that the contrast in mass surface density in the solar neighbourhood has standard deviation (in the surface density distribution) divided by mean of about 1/4 and larger than measured using COBE data by Drimmel and Spergel. Our estimate is consistent with a standard deviation of ˜0.07 dex in the metallicities measured from high-quality spectroscopic data for 38 young open clusters (<1 Gyr) with mean galactocentric radius 7-9 kpc.

  16. Arizona's Instrument to Measure Standards (AIMS DPA). Student Guide, Grade 8

    ERIC Educational Resources Information Center

    Arizona Department of Education, 2006

    2006-01-01

    Arizona's Instrument to Measure Standards (AIMS), a Standards-Based test, provides educators and the public with valuable information regarding the progress of Arizona's students toward mastering Arizona's reading, writing and mathematics Standards. This specific test, Arizona's Instrument to Measure Standards Dual Purpose Assessment (AIMS DPA) is…

  17. SOUTH CAROLINA GUIDE AND MINIMUM SPECIFICATIONS FOR MOBILE CLASSROOM UNITS.

    ERIC Educational Resources Information Center

    South Carolina State Education Finance Commission, Columbia. Office of Schoolhouse Planning.

    THIS GUIDE OF REQUIRED AND RECOMMENDED STANDARDS FOR MOBILE CLASSROOM UNITS IS INTENDED TO--(1) PROVIDE A GUIDE TO LOCAL SCHOOL AUTHORITIES TO ASSIST THEM IN DETERMINING THE FEASIBILITY OF MOBILE UNITS, (2) SET MINIMUM SAFETY AND UTILITY REQUIREMENTS FOR MOBILE UNITS, (3) ASSURE LOCAL SCHOOL AUTHORITIES OF A MOBILE UNIT MEETING THE ABOVE…

  18. The Challenge of Governance. Teacher's Guide [and Student Text]. W.M. Keck Foundation Series.

    ERIC Educational Resources Information Center

    Croddy, Marshall; Degelman, Charles; Hayes, Bill

    This teacher's guide and student text is the fourth volume in the W. M. Keck Foundation Series. The guide, which is designed to provide instructional support for classroom use of "The Challenge of Governance," gives teachers an opportunity to review content from the National Standards for Civics and Government for High School with…

  19. Making Sense of Census 2000--U.S. Virgin Islands. [Teaching Guide]. Grades K-12.

    ERIC Educational Resources Information Center

    Bureau of the Census (DOC), Suitland, MD.

    The United States Census Bureau's mission is to be the preeminent collector and provider of timely, relevant, and quality data about the nation's people and economy. The Census 2000 teaching guide aims to help teachers bring the census to life for students. The guide outlines skills that correlate with national standards; fulfills curriculum…

  20. Self-Study and Evaluation Guide/1968 Edition. Section D-3: Rehabilitation Centers.

    ERIC Educational Resources Information Center

    National Accreditation Council for Agencies Serving the Blind and Visually Handicapped, New York, NY.

    This self-study and evaluation guide on rehabilitation centers is one of 28 guides designed for organizations undertaking a self-study as part of the process for accreditation from the National Accreditation Council (NAC) for agencies serving the blind and visually handicapped. Provided are lists of standards to be appraised by the self-evaluation…

  1. Self-Study and Evaluation Guide/1977 Edition. Section D-8: Rehabilitation Teaching Services.

    ERIC Educational Resources Information Center

    National Accreditation Council for Agencies Serving the Blind and Visually Handicapped, New York, NY.

    This self-study and evaluation guide on rehabilitation teaching services is one of 28 guides designed for organizations who are undertaking a self-study as part of the process for accreditation from the National Accreditation Council (NAC) for agencies serving the blind and visually handicapped. Provided are lists of standards to be appraised by…

  2. Self-Study and Evaluation Guide [1976 Edition]. Section D-4: Workshop Services.

    ERIC Educational Resources Information Center

    National Accreditation Council for Agencies Serving the Blind and Visually Handicapped, New York, NY.

    This self-study and evaluation guide on workshop service is one of twenty-eight guides designed for organizations who are undertaking a self-study as part of the process for accreditation from the National Accreditation Council (NAC) for agencies serving the blind and visually handicapped. Provided are lists of standards to be appraised by the…

  3. Self-Study and Evaluation Guide/[1975 Edition]. Section D-6: Vocational Services.

    ERIC Educational Resources Information Center

    National Accreditation Council for Agencies Serving the Blind and Visually Handicapped, New York, NY.

    This self-study and evaluation guide on vocational services is one of 28 guides designed for organizations who are undertaking a self-study as part of the process for accreditation from the National Accreditation Council (NAC) for agencies serving the blind and visually handicapped. Provided are lists of standards to be appraised by the…

  4. Standards of Excellence for School Nutrition Programs. A Self-Assessment Guide for School District Fiscal Policy Teams.

    ERIC Educational Resources Information Center

    California State Dept. of Education, Sacramento.

    This guide was developed for fiscal policy team members to familiarize them with district policies, processes, available data, mandated responsibilities, and other requirements essential to federal and state funded school nutrition program operations. The guide is divided into nine sections: (1) organization and administration; (2) human resources…

  5. A Builder's Guide to Super Good Cents Contruction and Sales.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    OSU Extension Energy Program; United States. Bonneville Power Administration.

    This Builder's guide describes the Super Good Cents {reg sign} program and the benefits available to participating builders. It explains the program standards and the typical building techniques used by Super Good Cents builders. Finally, the guide tells how you can participate and answers many of the questions asked by builders about the Super Good Cents program.

  6. Introduction to Algebra Curriculum Guide, Grade 8, 1987. Bulletin 1802.

    ERIC Educational Resources Information Center

    Louisiana State Dept. of Education, Baton Rouge. Div. of Academic Programs.

    Because of the high incidence of failure in algebra I among ninth-grade students, the Louisiana State Board of Elementary and Secondary Education requested the development of this guide with the intention of providing a good pre-algebra foundation. The purposes of the guide are to recognize standards that involve the application of mathematical…

  7. Pre-recorded instructional audio vs. dispatchers' conversational assistance in telephone cardiopulmonary resuscitation: A randomized controlled simulation study.

    PubMed

    Birkun, Alexei; Glotov, Maksim; Ndjamen, Herman Franklin; Alaiye, Esther; Adeleke, Temidara; Samarin, Sergey

    2018-01-01

    To assess the effectiveness of the telephone chest-compression-only cardiopulmonary resuscitation (CPR) guided by a pre-recorded instructional audio when compared with dispatcher-assisted resuscitation. It was a prospective, blind, randomised controlled study involving 109 medical students without previous CPR training. In a standardized mannequin scenario, after the step of dispatcher-assisted cardiac arrest recognition, the participants performed compression-only resuscitation guided over the telephone by either: (1) the pre-recorded instructional audio ( n =57); or (2) verbal dispatcher assistance ( n =52). The simulation video records were reviewed to assess the CPR performance using a 13-item checklist. The interval from call reception to the first compression, total number and rate of compressions, total number and duration of pauses after the first compression were also recorded. There were no significant differences between the recording-assisted and dispatcher-assisted groups based on the overall performance score (5.6±2.2 vs. 5.1±1.9, P >0.05) or individual criteria of the CPR performance checklist. The recording-assisted group demonstrated significantly shorter time interval from call receipt to the first compression (86.0±14.3 vs. 91.2±14.2 s, P <0.05), higher compression rate (94.9±26.4 vs. 89.1±32.8 min -1 ) and number of compressions provided (170.2±48.0 vs. 156.2±60.7). When provided by untrained persons in the simulated settings, the compression-only resuscitation guided by the pre-recorded instructional audio is no less efficient than dispatcher-assisted CPR. Future studies are warranted to further assess feasibility of using instructional audio aid as a potential alternative to dispatcher assistance.

  8. An Approach for Preoperative Planning and Performance of MR-guided Interventions Demonstrated With a Manual Manipulator in a 1.5T MRI Scanner

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seimenis, Ioannis; Tsekos, Nikolaos V.; Keroglou, Christoforos

    2012-04-15

    Purpose: The aim of this work was to develop and test a general methodology for the planning and performance of robot-assisted, MR-guided interventions. This methodology also includes the employment of software tools with appropriately tailored routines to effectively exploit the capabilities of MRI and address the relevant spatial limitations. Methods: The described methodology consists of: (1) patient-customized feasibility study that focuses on the geometric limitations imposed by the gantry, the robotic hardware, and interventional tools, as well as the patient; (2) stereotactic preoperative planning for initial positioning of the manipulator and alignment of its end-effector with a selected target; andmore » (3) real-time, intraoperative tool tracking and monitoring of the actual intervention execution. Testing was performed inside a standard 1.5T MRI scanner in which the MR-compatible manipulator is deployed to provide the required access. Results: A volunteer imaging study demonstrates the application of the feasibility stage. A phantom study on needle targeting is also presented, demonstrating the applicability and effectiveness of the proposed preoperative and intraoperative stages of the methodology. For this purpose, a manually actuated, MR-compatible robotic manipulation system was used to accurately acquire a prescribed target through alternative approaching paths. Conclusions: The methodology presented and experimentally examined allows the effective performance of MR-guided interventions. It is suitable for, but not restricted to, needle-targeting applications assisted by a robotic manipulation system, which can be deployed inside a cylindrical scanner to provide the required access to the patient facilitating real-time guidance and monitoring.« less

  9. Pre-recorded instructional audio vs. dispatchers’ conversational assistance in telephone cardiopulmonary resuscitation: A randomized controlled simulation study

    PubMed Central

    Birkun, Alexei; Glotov, Maksim; Ndjamen, Herman Franklin; Alaiye, Esther; Adeleke, Temidara; Samarin, Sergey

    2018-01-01

    BACKGROUND: To assess the effectiveness of the telephone chest-compression-only cardiopulmonary resuscitation (CPR) guided by a pre-recorded instructional audio when compared with dispatcher-assisted resuscitation. METHODS: It was a prospective, blind, randomised controlled study involving 109 medical students without previous CPR training. In a standardized mannequin scenario, after the step of dispatcher-assisted cardiac arrest recognition, the participants performed compression-only resuscitation guided over the telephone by either: (1) the pre-recorded instructional audio (n=57); or (2) verbal dispatcher assistance (n=52). The simulation video records were reviewed to assess the CPR performance using a 13-item checklist. The interval from call reception to the first compression, total number and rate of compressions, total number and duration of pauses after the first compression were also recorded. RESULTS: There were no significant differences between the recording-assisted and dispatcher-assisted groups based on the overall performance score (5.6±2.2 vs. 5.1±1.9, P>0.05) or individual criteria of the CPR performance checklist. The recording-assisted group demonstrated significantly shorter time interval from call receipt to the first compression (86.0±14.3 vs. 91.2±14.2 s, P<0.05), higher compression rate (94.9±26.4 vs. 89.1±32.8 min-1) and number of compressions provided (170.2±48.0 vs. 156.2±60.7). CONCLUSION: When provided by untrained persons in the simulated settings, the compression-only resuscitation guided by the pre-recorded instructional audio is no less efficient than dispatcher-assisted CPR. Future studies are warranted to further assess feasibility of using instructional audio aid as a potential alternative to dispatcher assistance.

  10. Analysis of Photovoltaic System Energy Performance Evaluation Method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurtz, S.; Newmiller, J.; Kimber, A.

    2013-11-01

    Documentation of the energy yield of a large photovoltaic (PV) system over a substantial period can be useful to measure a performance guarantee, as an assessment of the health of the system, for verification of a performance model to then be applied to a new system, or for a variety of other purposes. Although the measurement of this performance metric might appear to be straight forward, there are a number of subtleties associated with variations in weather and imperfect data collection that complicate the determination and data analysis. A performance assessment is most valuable when it is completed with amore » very low uncertainty and when the subtleties are systematically addressed, yet currently no standard exists to guide this process. This report summarizes a draft methodology for an Energy Performance Evaluation Method, the philosophy behind the draft method, and the lessons that were learned by implementing the method.« less

  11. Precision guided antiaircraft munition

    DOEpatents

    Hirschfeld, Tomas B.

    1987-01-01

    A small diameter, 20 mm to 50 mm, guided projectile is used in antiaircraft defense. A pulsing laser designator illuminates the target aircraft. Energy reflected from the aircraft is received by the guided projectile. The guided projectile is fired from a standard weapon but the spining caused by the riflings are removed before active tracking and guidance occurs. The received energy is focused by immersion optics onto a bridge cell. AC coupling and gating removes background and allows steering signals to move extended vanes by means of piezoelectric actuators in the rear of the guided projectile.

  12. Radiology-guided forceps biopsy and airway stenting in severe airway stenosis.

    PubMed

    Li, Zong Ming; Wu, Gang; Han, Xin Wei; Ren, Ke Wei; Zhu, Ming

    2014-01-01

    We aimed to determine the feasibility, safety, and effectiveness of radiology-guided forceps biopsy and airway stenting in patients with severe airway stenosis. This study involved 28 patients with severe airway stenosis who underwent forceps biopsy between October 2006 and September 2011. Chest multislice computed tomography was used to determine the location and extent of stenosis. Sixteen patients had tracheal stenosis, two patients had stenosis of the tracheal carina, six patients had stenosis of the left main bronchus, and four patients had stenosis of the right main bronchus. Forceps biopsy and stenting of the stenosed area were performed under fluoroscopic guidance in digital subtraction angiography and the biopsy specimens were analyzed histopathologically. We contacted the patients via phone call and utilized a standardized questionnaire to determine their medical condition during a postoperative three-month follow-up. The technical success rate of radiology-guided forceps biopsy was 100%. Biopsy specimens were obtained in all patients. Dyspnea was relieved immediately after stent placement. No serious complications, such as tracheal hemorrhage or perforation, mediastinal emphysema, or asphyxia, occurred. Radiology-guided forceps biopsy and airway stenting can be used for the emergency treatment of severe airway stenosis. This method appears to be safe and effective, and it may be an alternative therapeutic option in patients who cannot tolerate fiberoptic bronchoscopy.

  13. The 4MOST facility control software

    NASA Astrophysics Data System (ADS)

    Pramskiy, Alexander; Mandel, Holger; Rothmaier, Florian; Stilz, Ingo; Winkler, Roland; Hahn, Thomas

    2016-07-01

    The 4-m Multi-Object Spectrographic Telescope (4MOST) is one high-resolution (R 18000) and two lowresolution (R fi 5000) spectrographs covering the wavelength range between 390 and 950 nm. The spectrographs will be installed on ESO VISTA telescope and will be fed by approximately 2400 fibres. The instrument is capable to simultaneously obtain spectra of about 2400 objects distributed over an hexagonal field-of-view of four square degrees. This paper aims at giving an overview of the control software design, which is based on the standard ESO VLT software architecture and customised to fit the needs of the 4MOST instrument. In particular, the facility control software is intended to arrange the precise positioning of the fibres, to schedule and observe many surveys in parallel, and to combine the output from the three spectrographs. Moreover, 4MOST's software will include user-friendly graphical user interfaces that enable users to interact with the facility control system and to monitor all data-taking and calibration tasks of the instrument. A secondary guiding system will be implemented to correct for any fibre exure and thus to improve 4MOST's guiding performance. The large amount of fibres requires the custom design of data exchange to avoid performance issues. The observation sequences are designed to use spectrographs in parallel with synchronous points for data exchange between subsystems. In order to control hardware devices, Programmable Logic Controller (PLC) components will be used, the new standard for future instruments at ESO.

  14. 45 CFR 170.299 - Incorporation by reference.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Drug Programs Prescriber/Pharmacist Interface SCRIPT Standard, Implementation Guide, Version 8, Release.... (1) National Council for Prescription Drug Programs Prescriber/Pharmacist Interface SCRIPT Standard...

  15. Performance-Based Assessment Resource Guide.

    ERIC Educational Resources Information Center

    Gilbert, Judith C.; Burger, Patricia

    This resource guide reviews a variety of performance-based student assessment strategies, and provides examples of, and references for, the strategies. Strategies include anecdotal records, interviews, peer report and group evaluations, and portfolios. Materials in the guide include: (1) a resource guide update form for teachers; (2) department…

  16. MRI-Targeted or Standard Biopsy for Prostate-Cancer Diagnosis.

    PubMed

    Kasivisvanathan, Veeru; Rannikko, Antti S; Borghi, Marcelo; Panebianco, Valeria; Mynderse, Lance A; Vaarala, Markku H; Briganti, Alberto; Budäus, Lars; Hellawell, Giles; Hindley, Richard G; Roobol, Monique J; Eggener, Scott; Ghei, Maneesh; Villers, Arnauld; Bladou, Franck; Villeirs, Geert M; Virdi, Jaspal; Boxler, Silvan; Robert, Grégoire; Singh, Paras B; Venderink, Wulphert; Hadaschik, Boris A; Ruffion, Alain; Hu, Jim C; Margolis, Daniel; Crouzet, Sébastien; Klotz, Laurence; Taneja, Samir S; Pinto, Peter; Gill, Inderbir; Allen, Clare; Giganti, Francesco; Freeman, Alex; Morris, Stephen; Punwani, Shonit; Williams, Norman R; Brew-Graves, Chris; Deeks, Jonathan; Takwoingi, Yemisi; Emberton, Mark; Moore, Caroline M

    2018-05-10

    Multiparametric magnetic resonance imaging (MRI), with or without targeted biopsy, is an alternative to standard transrectal ultrasonography-guided biopsy for prostate-cancer detection in men with a raised prostate-specific antigen level who have not undergone biopsy. However, comparative evidence is limited. In a multicenter, randomized, noninferiority trial, we assigned men with a clinical suspicion of prostate cancer who had not undergone biopsy previously to undergo MRI, with or without targeted biopsy, or standard transrectal ultrasonography-guided biopsy. Men in the MRI-targeted biopsy group underwent a targeted biopsy (without standard biopsy cores) if the MRI was suggestive of prostate cancer; men whose MRI results were not suggestive of prostate cancer were not offered biopsy. Standard biopsy was a 10-to-12-core, transrectal ultrasonography-guided biopsy. The primary outcome was the proportion of men who received a diagnosis of clinically significant cancer. Secondary outcomes included the proportion of men who received a diagnosis of clinically insignificant cancer. A total of 500 men underwent randomization. In the MRI-targeted biopsy group, 71 of 252 men (28%) had MRI results that were not suggestive of prostate cancer, so they did not undergo biopsy. Clinically significant cancer was detected in 95 men (38%) in the MRI-targeted biopsy group, as compared with 64 of 248 (26%) in the standard-biopsy group (adjusted difference, 12 percentage points; 95% confidence interval [CI], 4 to 20; P=0.005). MRI, with or without targeted biopsy, was noninferior to standard biopsy, and the 95% confidence interval indicated the superiority of this strategy over standard biopsy. Fewer men in the MRI-targeted biopsy group than in the standard-biopsy group received a diagnosis of clinically insignificant cancer (adjusted difference, -13 percentage points; 95% CI, -19 to -7; P<0.001). The use of risk assessment with MRI before biopsy and MRI-targeted biopsy was superior to standard transrectal ultrasonography-guided biopsy in men at clinical risk for prostate cancer who had not undergone biopsy previously. (Funded by the National Institute for Health Research and the European Association of Urology Research Foundation; PRECISION ClinicalTrials.gov number, NCT02380027 .).

  17. Bone augmentation at peri-implant dehiscence defects comparing a synthetic polyethylene glycol hydrogel matrix vs. standard guided bone regeneration techniques.

    PubMed

    Thoma, Daniel S; Jung, Ui-Won; Park, Jin-Young; Bienz, Stefan P; Hüsler, Jürg; Jung, Ronald E

    2017-07-01

    The aim of the study was to test whether or not the use of a polyethylene glycol (PEG) hydrogel with or without the addition of an arginylglycylaspartic acid (RGD) sequence applied as a matrix in combination with hydroxyapatite/tricalciumphosphate (HA/TCP) results in similar peri-implant bone regeneration as traditional guided bone regeneration procedures. In 12 beagle dogs, implant placement and peri-implant bone regeneration were performed 2 months after tooth extraction in the maxilla. Two standardized box-shaped defects were bilaterally created, and dental implants were placed in the center of the defects with a dehiscence of 4 mm. Four treatment modalities were randomly applied: i)HA/TCP mixed with a synthetic PEG hydrogel, ii)HA/TCP mixed with a synthetic PEG hydrogel supplemented with an RGD sequence, iii)HA/TCP covered with a native collagen membrane (CM), iv)and no bone augmentation (empty). After a healing period of 8 or 16 weeks, micro-CT and histological analyses were performed. Histomorphometric analysis revealed a greater relative augmented area for groups with bone augmentation (43.3%-53.9% at 8 weeks, 31.2%-42.8% at 16 weeks) compared to empty controls (22.9% at 8 weeks, 1.1% at 16 weeks). The median amount of newly formed bone was greatest in group CM at both time-points. Regarding the first bone-to-implant contact, CM was statistically significantly superior to all other groups at 8 weeks. Bone can partially be regenerated at peri-implant buccal dehiscence defects using traditional guided bone regeneration techniques. The use of a PEG hydrogel applied as a matrix mixed with a synthetic bone substitute material might lack a sufficient stability over time for this kind of defect. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Energy and Environment Guide to Action - Chapter 4.4: State Appliance Efficiency Standards

    EPA Pesticide Factsheets

    Provides recommendations on designing, implementing, and evaluating state appliance efficiency standards. Appliance standards save energy and generate net benefits for homes, businesses, and industry. State success stories are included for reference.

  19. The development of professional practice standards for Australian general practice nurses.

    PubMed

    Halcomb, Elizabeth; Stephens, Moira; Bryce, Julianne; Foley, Elizabeth; Ashley, Christine

    2017-08-01

    The aim of this study was to explore the current role of general practice nurses and the scope of nursing practice to inform the development of national professional practice standards for Australian general practice nurses. Increasing numbers of nurses have been employed in Australian general practice to meet the growing demand for primary care services. This has brought significant changes to the nursing role. Competency standards for nurses working in general practice were first developed in Australia in 2005, but limited attention has been placed on articulating the contemporary scope of practice for nurses in this setting. Concurrent mixed methods design. Data collection was conducted during 2013-2014 and involved two online surveys of Registered and Enrolled Nurses currently working in general practice, a series of 14 focus groups across Australia and a series of consultations with key experts. Data collection enabled the development of 22 Practice Standards separated into four domains: (i) Professional Practice; (ii) Nursing Care; (iii) General Practice Environment and (iv) Collaborative Practice. To differentiate the variations in enacting these Standards, performance indicators for the Enrolled Nurse, Registered Nurse and Registered Nurse Advanced Practice are provided under each Standard. The development of national professional practice standards for nurses working in Australian general practice will support ongoing workforce development. These Standards are also an important means of articulating the role and scope of the nurses' practice for both consumers and other health professionals, as well as being a guide for curriculum development and measurement of performance. © 2017 John Wiley & Sons Ltd.

  20. Novel endoscopic delivery modality of infrared coagulation therapy for internal hemorrhoids.

    PubMed

    McLemore, Elisabeth C; Rai, Rudra; Siddiqui, Junaid; Basu, P Patrick; Tabbaa, Mousab; Epstein, Michael S

    2012-11-01

    A novel endoscopic delivery system for infrared coagulation therapy (IRC) has been designed recently. IRC is a well-established treatment for symptomatic internal hemorrhoids. Patients frequently undergo lower endoscopy before hemorrhoid treatment to eliminate other sources of bleeding. Current treatment options are difficult to perform without an anal retractor, adequate lighting, and specialized instruments. Endoscopic IRC is an attractive alternative to standard IRC, because it can be performed during the lower endoscopy. Endoscopic IRC utilizes infrared radiation generated by a control box, which is applied to the tissue through a flexible, fiber optic light guide (Precision Endoscopic Infrared Coagulator™). The light guide is placed through the colonoscope or flexible sigmoidoscope in the same chamber as other endoscopic instruments. A retrospective review was performed using a prospectively collected database. A standardized protocol was utilized in all patients. Patients graded their symptoms before and after therapy by using the visual analog symptom severity scoring system (range, 0-10). These results were analyzed by using the nonparametric Wilcoxon signed-rank test. Exact P values were computed by using the R function wilcox.exact. A total of 55 patients underwent endoscopic IRC for predominately grade II and grade III symptomatic internal hemorrhoids (71 %). There were 22 (40 %) female patients. Posttherapy results indicated a significant improvement in global symptoms (pretreatment average global score = 2.24 vs. posttreatment average global score = 0.28; P < 0.0001). There have been no adverse events reported to date. Endoscopic IRC provides improved visibility and efficiency, allowing simultaneous treatment of symptomatic internal hemorrhoids at the time of lower endoscopy. Patients experienced significant improvement in their symptoms after a single session of endoscopic IRC. There are a variety of additional endoscopic IRC therapeutic utilities: endoscopic management of angiodysplasia, inflammation, hemostasis, and NOTES applications.

Top