Sample records for performance test test

  1. Understanding pretest and posttest reactions to cognitive ability and personality tests.

    PubMed

    Chan, D; Schmitt, N; Sacco, J M; DeShon, R P

    1998-06-01

    To understand the nature of test reactions and their relationship to test performance, the relationships among belief in tests, pretest reactions, test performance, and posttest reactions were modeled for cognitive ability and personality tests. Results from structural equation models that were fitted to responses from 197 undergraduate examinees supported the hypothesized relationships. On the cognitive ability test, pretest reactions affected test performance and mediated the relationship between belief in tests and test performance. Test performance affected posttest reactions even after taking into account the effect of pretest reactions. On the personality test, belief in tests affected pretest and posttest reactions, but the three variables were unrelated to test performance (Conscientiousness scores). Conceptual, methodological, and practical implications of the findings are discussed in the context of research on test reactions and test performance.

  2. Electrical Evaluation of RCA MWS5001D Random Access Memory, Volume 1

    NASA Technical Reports Server (NTRS)

    Klute, A.

    1979-01-01

    Electrical characterization and qualification tests were performed on the RCA MWS5001D, 1024 by 1-bit, CMOS, random access memory. Characterization tests were performed on five devices. The tests included functional tests, AC parametric worst case pattern selection test, determination of worst-case transition for setup and hold times and a series of schmoo plots. The qualification tests were performed on 32 devices and included a 2000 hour burn in with electrical tests performed at 0 hours and after 168, 1000, and 2000 hours of burn in. The tests performed included functional tests and AC and DC parametric tests. All of the tests in the characterization phase, with the exception of the worst-case transition test, were performed at ambient temperatures of 25, -55 and 125 C. The worst-case transition test was performed at 25 C. The preburn in electrical tests were performed at 25, -55, and 125 C. All burn in endpoint tests were performed at 25, -40, -55, 85, and 125 C.

  3. Understanding protocol performance: impact of test performance.

    PubMed

    Turner, Robert G

    2013-01-01

    This is the second of two articles that examine the factors that determine protocol performance. The objective of these articles is to provide a general understanding of protocol performance that can be used to estimate performance, establish limits on performance, decide if a protocol is justified, and ultimately select a protocol. The first article was concerned with protocol criterion and test correlation. It demonstrated the advantages and disadvantages of different criterion when all tests had the same performance. It also examined the impact of increasing test correlation on protocol performance and the characteristics of the different criteria. To examine the impact on protocol performance when individual tests in a protocol have different performance. This is evaluated for different criteria and test correlations. The results of the two articles are combined and summarized. A mathematical model is used to calculate protocol performance for different protocol criteria and test correlations when there are small to large variations in the performance of individual tests in the protocol. The performance of the individual tests that make up a protocol has a significant impact on the performance of the protocol. As expected, the better the performance of the individual tests, the better the performance of the protocol. Many of the characteristics of the different criteria are relatively independent of the variation in the performance of the individual tests. However, increasing test variation degrades some criteria advantages and causes a new disadvantage to appear. This negative impact increases as test variation increases and as more tests are added to the protocol. Best protocol performance is obtained when individual tests are uncorrelated and have the same performance. In general, the greater the variation in the performance of tests in the protocol, the more detrimental this variation is to protocol performance. Since this negative impact is increased as more tests are added to the protocol, greater test variation indicates using fewer tests in the protocol. American Academy of Audiology.

  4. SWI 1.10 Testing Process

    NASA Technical Reports Server (NTRS)

    Stokes, LeBarian

    2009-01-01

    This procedure establishes a system for performing testing in the Six-Degree-Of-Freedom Dynamic Test System (SDTS). Testing includes development and verification testing of customer supplied Test Articles (TAs) and other testing requirements, as requested. This procedure applies to all SDTS testing operations and equipment. The procedure provides an overview of testing performed in the SDTS including test identification requirements, test planning and procedure development, test and performance inspection, test data analysis, and test report generation.

  5. Functional performance testing for power and return to sports.

    PubMed

    Manske, Robert; Reiman, Michael

    2013-05-01

    Functional performance testing of athletes can determine physical limitations that may affect sporting activities. Optimal functional performance testing simulates the athlete's activity. A Medline search from 1960 to 2012 was implemented with the keywords functional testing, functional impairment testing, and functional performance testing in the English language. Each author also undertook independent searches of article references. Functional performance tests can bridge the gap between general physical tests and full, unrestricted athletic activity.

  6. Small passenger car transmission test: Dodge Omni A-404 transmission

    NASA Technical Reports Server (NTRS)

    Bujold, M. P.

    1980-01-01

    The small passenger car transmission test was initiated to supply electric vehicle manufacturers with technical information regarding the performance of commercially available transmissions. This transmission was tested in accordance with a passenger car automatic transmission test code (SAE J65lb) which required drive performance, coast performance, and no load test conditions. Under these test conditions, the transmission attained maximum efficiencies in the mid eighty percent range for both drive performance test and coast performance tests.

  7. Students' Geographic Knowledge and Skills in Different Kinds of Tests: Multiple-Choice versus Performance Assessment.

    ERIC Educational Resources Information Center

    Kon, Jane Heckley; Martin-Kniep, Giselle O.

    1992-01-01

    Describes a case study to determine whether performance tests are a feasible alternative to multiple-choice tests. Examines the difficulties of administering and scoring performance assessments. Explains that the study employed three performance tests and one multiple-choice test. Concludes that performance test administration and scoring was no…

  8. 49 CFR Appendix A to Part 665 - Tests To Be Performed at the Bus Testing Facility

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 7 2014-10-01 2014-10-01 false Tests To Be Performed at the Bus Testing Facility... Part 665—Tests To Be Performed at the Bus Testing Facility The eight tests to be performed on each vehicle are required by SAFETEA-LU and are based in part on tests described in the FTA report “First...

  9. 49 CFR Appendix A to Part 665 - Tests To Be Performed at the Bus Testing Facility

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Tests To Be Performed at the Bus Testing Facility... Part 665—Tests To Be Performed at the Bus Testing Facility The eight tests to be performed on each vehicle are required by SAFETEA-LU and are based in part on tests described in the FTA report “First...

  10. Chinese College Test Takers' Individual Differences and Reading Test Performance: A Structural Equation Modeling Approach.

    PubMed

    Zhang, Limei

    2016-06-01

    This study reports on the relationships between test takers' individual differences and their performance on a reading comprehension test. A total of 518 Chinese college students (252 women and 256 men; M age = 19.26 year, SD = 0.98) answered a questionnaire and sit for a reading comprehension test. The study found that test takers' L2 language proficiency was closely linked to their test performance. Test takers' employment of strategies was significantly and positively associated with their performance on the test. Test takers' motivation was found to be significantly associated with reading test performance. Test anxiety was negatively related to their use of reading strategies and test performance. The results of the study lent support to the threshold hypothesis of language proficiency. The implications for classroom teaching were provided. © The Author(s) 2016.

  11. Small passenger car transmission test; Chevrolet LUV transmission

    NASA Technical Reports Server (NTRS)

    Bujold, M. P.

    1980-01-01

    A 1978 Chevrolet LUV manual transmission tested per the applicable portions of a passenger car automatic transmission test code (SAE J65lb) which required drive performance, coast performance, and no load test conditions. Under these test conditions, the transmission attained maximum efficiencies in the upper ninety percent range for both drive performance tests and coast performance tests. The major results of this test (torque, speed, and efficiency curves) are presented. Graphs map the complete performance characteristics for the Chevrolet LUV transmission.

  12. Small passenger car transmission test; Ford C4 transmission

    NASA Technical Reports Server (NTRS)

    Bujold, M. P.

    1980-01-01

    A 1979 Ford C4 automatic transmission was tested per a passenger car automatic transmission test code (SAE J651b) which required drive performance, coast performance, and no load test conditions. Under these test conditions, the transmission attained maximum efficiencies in the mid-eighty percent range for both drive performance tests and coast performance tests. The major results of this test (torque, speed, and efficiency curves) are presented. Graphs map the complete performance characteristics for the Ford C4 transmission.

  13. Functional Performance Testing for Power and Return to Sports

    PubMed Central

    Manske, Robert; Reiman, Michael

    2013-01-01

    Context: Functional performance testing of athletes can determine physical limitations that may affect sporting activities. Optimal functional performance testing simulates the athlete’s activity. Evidence Acquisition: A Medline search from 1960 to 2012 was implemented with the keywords functional testing, functional impairment testing, and functional performance testing in the English language. Each author also undertook independent searches of article references. Conclusion: Functional performance tests can bridge the gap between general physical tests and full, unrestricted athletic activity. PMID:24427396

  14. 40 CFR 60.4400 - How do I conduct the initial and subsequent performance tests, regarding NOX?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... subsequent performance tests, regarding NOX? 60.4400 Section 60.4400 Protection of Environment ENVIRONMENTAL... Standards of Performance for Stationary Combustion Turbines Performance Tests § 60.4400 How do I conduct the initial and subsequent performance tests, regarding NOX? (a) You must conduct an initial performance test...

  15. 40 CFR 60.4400 - How do I conduct the initial and subsequent performance tests, regarding NOX?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... subsequent performance tests, regarding NOX? 60.4400 Section 60.4400 Protection of Environment ENVIRONMENTAL... Standards of Performance for Stationary Combustion Turbines Performance Tests § 60.4400 How do I conduct the initial and subsequent performance tests, regarding NOX? (a) You must conduct an initial performance test...

  16. 40 CFR 60.4400 - How do I conduct the initial and subsequent performance tests, regarding NOX?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... subsequent performance tests, regarding NOX? 60.4400 Section 60.4400 Protection of Environment ENVIRONMENTAL... Standards of Performance for Stationary Combustion Turbines Performance Tests § 60.4400 How do I conduct the initial and subsequent performance tests, regarding NOX? (a) You must conduct an initial performance test...

  17. 40 CFR 60.4400 - How do I conduct the initial and subsequent performance tests, regarding NOX?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... subsequent performance tests, regarding NOX? 60.4400 Section 60.4400 Protection of Environment ENVIRONMENTAL... Standards of Performance for Stationary Combustion Turbines Performance Tests § 60.4400 How do I conduct the initial and subsequent performance tests, regarding NOX? (a) You must conduct an initial performance test...

  18. 40 CFR 60.4400 - How do I conduct the initial and subsequent performance tests, regarding NOX?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... subsequent performance tests, regarding NOX? 60.4400 Section 60.4400 Protection of Environment ENVIRONMENTAL... Standards of Performance for Stationary Combustion Turbines Performance Tests § 60.4400 How do I conduct the initial and subsequent performance tests, regarding NOX? (a) You must conduct an initial performance test...

  19. 40 CFR 63.504 - Additional requirements for performance testing.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Additional requirements for performance... Additional requirements for performance testing. (a) Performance testing shall be conducted in accordance.... Sections 63.484 through 63.501 also contain specific testing requirements. (1) Performance tests shall be...

  20. Performance Testing of a Trace Contaminant Control Subassembly for the International Space Station

    NASA Technical Reports Server (NTRS)

    Perry, J. L.; Curtis, R. E.; Alexandre, K. L.; Ruggiero, L. L.; Shtessel, N.

    1998-01-01

    As part of the International Space Station (ISS) Trace Contaminant Control Subassembly (TCCS) development, a performance test has been conducted to provide reference data for flight verification analyses. This test, which used the U.S. Habitation Module (U.S. Hab) TCCS as the test article, was designed to add to the existing database on TCCS performance. Included in this database are results obtained during ISS development testing; testing of functionally similar TCCS prototype units; and bench scale testing of activated charcoal, oxidation catalyst, and granular lithium hydroxide (LiOH). The present database has served as the basis for the development and validation of a computerized TCCS process simulation model. This model serves as the primary means for verifying the ISS TCCS performance. In order to mitigate risk associated with this verification approach, the U.S. Hab TCCS performance test provides an additional set of data which serve to anchor both the process model and previously-obtained development test data to flight hardware performance. The following discussion provides relevant background followed by a summary of the test hardware, objectives, requirements, and facilities. Facility and test article performance during the test is summarized, test results are presented, and the TCCS's performance relative to past test experience is discussed. Performance predictions made with the TCCS process model are compared with the U.S. Hab TCCS test results to demonstrate its validation.

  1. Improving Test-Taking Performance of Secondary At-Risk Youth and Students with Disabilities

    ERIC Educational Resources Information Center

    Banks, Tachelle; Eaton, India

    2014-01-01

    Preparing at-risk youth and students with mild disabilities for state and district tests is important for improving their test performance, and basic instruction in test preparation can significantly improve student test performance. The article defines noncognitive variables that adversely affect test-taker performance. The article also describes…

  2. 40 CFR 610.63 - Performance tests.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Performance tests. 610.63 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.63 Performance tests. The effect of a device on a vehicle's performance will be determined by performing wide-open-throttle...

  3. 40 CFR 60.8 - Performance tests.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Performance tests. 60.8 Section 60.8... PERFORMANCE FOR NEW STATIONARY SOURCES General Provisions § 60.8 Performance tests. (a) Except as specified in... conduct performance test(s) and furnish the Administrator a written report of the results of such...

  4. 40 CFR 63.7 - Performance testing requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Performance testing requirements. (a) Applicability and performance test dates. (1) The applicability of this... or operator of the affected source must perform such tests within 180 days of the compliance date for... standard initially, the owner or operator shall conduct a second performance test within 3 years and 180...

  5. Transit car demonstration test program on the roll dynamics unit. Volume 2. Demonstration of a transit car performance test on the roll dynamic unit. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arnold, G.; Nelson, S.; Cooperrider, N.K.

    1982-02-11

    This report, Volume II, contains the results, conclusions, and recommendations of the first performance test of a transit care on the RDU. This report is limited to performance tests. The objective is to identify advantages and disadvantages of performance testing on the rollers of the RDU as highlighted by the SOAC test. The report involved separate testing, done by TTC personnel, in such traditional performance areas of transit vehicle operation ass traction, acceleration/deceleration, energy consumption, and spin/slide performance. The results of the successful performance test of a transit car on a roller unit is presented and the advantages of thismore » method of testing is discussed. Acceleration, deceleration, spin/slide, and power consumption tests, although of limited scope in comparison to the track tests performed on the same transit car, did show the feasibility of roller testing. It is concluded that the RDU is most suited for developmental testing of transit car systems particularly for power consumption and for cars with non-standard wheel gage. Tests should be of such scope as to justify the cost of car setup on the RDU. The following two test are recommended: (1) a power consumption study for a standard/non-standard gage transit car which investigates methods of reducing power consumption and (2) a non-standard gage full performance test.« less

  6. GOES Type III Loop Heat Pipe Life Test Results

    NASA Technical Reports Server (NTRS)

    Ottenstein, Laura

    2011-01-01

    The GOES Type III Loop Heat Pipe (LHP) was built as a life test unit for the loop heat pipes on the GOES N-Q series satellites. This propylene LHP was built by Dynatherm Corporation in 2000 and tested continuously for approximately 14 months. It was then put into storage for 3 years. Following the storage period, the LHP was tested at Swales Aerospace to verify that the loop performance hadn t changed. Most test results were consistent with earlier results. At the conclusion of testing at Swales, the LHP was transferred to NASA/GSFC for continued periodic testing. The LHP has been set up for testing in the Thermal Lab at GSFC since 2006. A group of tests consisting of start-ups, power cycles, and a heat transport limit test have been performed every six to nine months since March 2006. Tests results have shown no change in the loop performance over the five years of testing. This presentation will discuss the test hardware, test set-up, and tests performed. Test results to be presented include sample plots from individual tests, along with conductance measurements for all tests performed.

  7. Small passenger car transmission test: Mercury Lynx ATX transmission

    NASA Technical Reports Server (NTRS)

    Bujold, M. P.

    1981-01-01

    The testing of a Mercury Lynx automatic transmission is reported. The transmission was tested in accordance with a passenger car automatic transmission test code (SAE J65lb) which required drive performance, coast performance, and no load test conditions. Under these conditions, the transmission attained maximum efficiencies in the mid-ninety percent range both for drive performance test and coast performance tests. The torque, speed, and efficiency curves are presented, which provide the complete performance characteristics for the Mercury Lynx automatic transmission.

  8. The intra- and inter-rater reliability of five clinical muscle performance tests in patients with and without neck pain

    PubMed Central

    2013-01-01

    Background This study investigates the reliability of muscle performance tests using cost- and time-effective methods similar to those used in clinical practice. When conducting reliability studies, great effort goes into standardising test procedures to facilitate a stable outcome. Therefore, several test trials are often performed. However, when muscle performance tests are applied in the clinical setting, clinicians often only conduct a muscle performance test once as repeated testing may produce fatigue and pain, thus variation in test results. We aimed to investigate whether cervical muscle performance tests, which have shown promising psychometric properties, would remain reliable when examined under conditions similar to those of daily clinical practice. Methods The intra-rater (between-day) and inter-rater (within-day) reliability was assessed for five cervical muscle performance tests in patients with (n = 33) and without neck pain (n = 30). The five tests were joint position error, the cranio-cervical flexion test, the neck flexor muscle endurance test performed in supine and in a 45°-upright position and a new neck extensor test. Results Intra-rater reliability ranged from moderate to almost perfect agreement for joint position error (ICC ≥ 0.48-0.82), the cranio-cervical flexion test (ICC ≥ 0.69), the neck flexor muscle endurance test performed in supine (ICC ≥ 0.68) and in a 45°-upright position (ICC ≥ 0.41) with the exception of a new test (neck extensor test), which ranged from slight to moderate agreement (ICC = 0.14-0.41). Likewise, inter-rater reliability ranged from moderate to almost perfect agreement for joint position error (ICC ≥ 0.51-0.75), the cranio-cervical flexion test (ICC ≥ 0.85), the neck flexor muscle endurance test performed in supine (ICC ≥ 0.70) and in a 45°-upright position (ICC ≥ 0.56). However, only slight to fair agreement was found for the neck extensor test (ICC = 0.19-0.25). Conclusions Intra- and inter-rater reliability ranged from moderate to almost perfect agreement with the exception of a new test (neck extensor test), which ranged from slight to moderate agreement. The significant variability observed suggests that tests like the neck extensor test and the neck flexor muscle endurance test performed in a 45°-upright position are too unstable to be used when evaluating neck muscle performance. PMID:24299621

  9. 40 CFR 60.2922 - How do I conduct the initial and annual performance test?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... of this part must be used. (ii) The post-test moisture removal procedure described in section 8.1.6... performance test? 60.2922 Section 60.2922 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Testing § 60.2922 How do I conduct the initial and annual performance test? (a) All performance tests must...

  10. 40 CFR 60.2922 - How do I conduct the initial and annual performance test?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... of this part must be used. (ii) The post-test moisture removal procedure described in section 8.1.6... performance test? 60.2922 Section 60.2922 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Testing § 60.2922 How do I conduct the initial and annual performance test? (a) All performance tests must...

  11. 10 CFR 707.11 - Drugs for which testing is performed.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 4 2014-01-01 2014-01-01 false Drugs for which testing is performed. 707.11 Section 707... Drugs for which testing is performed. Where testing is performed under this part, at a minimum... occurrence testing, the contractor may test for any drug listed in Schedules I or II of the Controlled...

  12. 10 CFR 707.11 - Drugs for which testing is performed.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 4 2013-01-01 2013-01-01 false Drugs for which testing is performed. 707.11 Section 707... Drugs for which testing is performed. Where testing is performed under this part, at a minimum... occurrence testing, the contractor may test for any drug listed in Schedules I or II of the Controlled...

  13. 10 CFR 707.11 - Drugs for which testing is performed.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Drugs for which testing is performed. 707.11 Section 707... Drugs for which testing is performed. Where testing is performed under this part, at a minimum... occurrence testing, the contractor may test for any drug listed in Schedules I or II of the Controlled...

  14. 10 CFR 707.11 - Drugs for which testing is performed.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 4 2012-01-01 2012-01-01 false Drugs for which testing is performed. 707.11 Section 707... Drugs for which testing is performed. Where testing is performed under this part, at a minimum... occurrence testing, the contractor may test for any drug listed in Schedules I or II of the Controlled...

  15. 10 CFR 707.11 - Drugs for which testing is performed.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Drugs for which testing is performed. 707.11 Section 707... Drugs for which testing is performed. Where testing is performed under this part, at a minimum... occurrence testing, the contractor may test for any drug listed in Schedules I or II of the Controlled...

  16. 40 CFR 610.63 - Performance tests.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Performance tests. 610.63 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.63 Performance tests... 0 to 60 mph acceleration tests (at normal ambient temperatures) on the baseline vehicle...

  17. 40 CFR 610.63 - Performance tests.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Performance tests. 610.63 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.63 Performance tests... 0 to 60 mph acceleration tests (at normal ambient temperatures) on the baseline vehicle...

  18. 40 CFR 610.63 - Performance tests.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Performance tests. 610.63 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.63 Performance tests... 0 to 60 mph acceleration tests (at normal ambient temperatures) on the baseline vehicle...

  19. 40 CFR 610.63 - Performance tests.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Performance tests. 610.63 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.63 Performance tests... 0 to 60 mph acceleration tests (at normal ambient temperatures) on the baseline vehicle...

  20. Does Performing Preplacement Workplace Hair Drug Testing Influence US Department of Transportation Random and Postaccident Urine Drug Test Positivity Rates?

    PubMed

    Price, James W

    Does performing pre-employment hair drug testing subsequently affect the prevalence of positive random and postaccident urine drug tests? This cross-sectional study was designed to evaluate the prevalence of positive postaccident and random workplace urine drug tests for companies that perform pre-employment hair and urine drug testing to companies that only perform pre-employment urine drug testing. Fisher exact test of independence indicated no significant difference between pre-employment hair drug testing and overall US Department of Transportation random and postaccident urine drug test positivity rates. The analysis failed to reject the null hypothesis, suggesting that pre-employment hair drug testing had no effect upon random and postaccident urine drug test positivity rates.

  1. Power Performance Test Report for the Viryd CS8 Wind Turbine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roadman, J.; Murphy, M.; van Dam, J.

    2012-12-01

    This report contains the results of the power performance test that was performed on a Viryd CS8 wind turbine as part of the DOE Independent Testing project. The test is an accredited test to the IEC 61400-12-1 power performance standard.

  2. Consideration of "g" as a Common Antecedent for Cognitive Ability Test Performance, Test Motivation, and Perceived Fairness

    ERIC Educational Resources Information Center

    Reeve, Charlie L.; Lam, Holly

    2007-01-01

    Several different analyses were used to test the hypothesis that test-taking motivation, perceived test fairness, and actual test performance are correlated only because they share a common antecedent. First, hierarchical regressions reveal that initial test performance has a unique influence on non-ability factors even after controlling for…

  3. 40 CFR 1066.430 - Performing emission tests.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Performing emission tests. 1066.430... CONTROLS VEHICLE-TESTING PROCEDURES Vehicle Preparation and Running a Test § 1066.430 Performing emission tests. The overall test consists of prescribed sequences of fueling, parking, and driving at specified...

  4. 40 CFR 1066.430 - Performing emission tests.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Performing emission tests. 1066.430... CONTROLS VEHICLE-TESTING PROCEDURES Vehicle Preparation and Running a Test § 1066.430 Performing emission tests. The overall test consists of prescribed sequences of fueling, parking, and driving at specified...

  5. Performance testing accountability measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oldham, R.D.; Mitchell, W.G.; Spaletto, M.I.

    The New Brunswick Laboratory (NBL) provides assessment support to the DOE Operations Offices in the area of Material Control and Accountability (MC and A). During surveys of facilities, the Operations Offices have begun to request from NBL either assistance in providing materials for performance testing of accountability measurements or both materials and personnel to do performance testing. To meet these needs, NBL has developed measurement and measurement control performance test procedures and materials. The present NBL repertoire of performance tests include the following: (1) mass measurement performance testing procedures using calibrated and traceable test weights, (2) uranium elemental concentration (assay)more » measurement performance tests which use ampulated solutions of normal uranyl nitrate containing approximately 7 milligrams of uranium per gram of solution, and (3) uranium isotopic measurement performance tests which use ampulated uranyl nitrate solutions with enrichments ranging from 4% to 90% U-235. The preparation, characterization, and packaging of the uranium isotopic and assay performance test materials were done in cooperation with the NBL Safeguards Measurements Evaluation Program since these materials can be used for both purposes.« less

  6. Development of a standardized battery of performance tests for the assessment of noise stress effects

    NASA Technical Reports Server (NTRS)

    Theologus, G. C.; Wheaton, G. R.; Mirabella, A.; Brahlek, R. E.

    1973-01-01

    A set of 36 relatively independent categories of human performance were identified. These categories encompass human performance in the cognitive, perceptual, and psychomotor areas, and include diagnostic measures and sensitive performance metrics. Then a prototype standardized test battery was constructed, and research was conducted to obtain information on the sensitivity of the tests to stress, the sensitivity of selected categories of performance degradation, the time course of stress effects on each of the selected tests, and the learning curves associated with each test. A research project utilizing a three factor partially repeated analysis of covariance design was conducted in which 60 male subjects were exposed to variations in noise level and quality during performance testing. Effects of randomly intermittent noise on performance of the reaction time tests were observed, but most of the other performance tests showed consistent stability. The results of 14 analyses of covariance of the data taken from the performance of the 60 subjects on the prototype standardized test battery provided information which will enable the final development and test of a standardized test battery and the associated development of differential sensitivity metrics and diagnostic classificatory system.

  7. Stereotype Threat, Test Anxiety, and Mathematics Performance

    ERIC Educational Resources Information Center

    Tempel, Tobias; Neumann, Roland

    2014-01-01

    We investigated the combined effects of stereotype threat and trait test anxiety on mathematics test performance. Stereotype threat and test anxiety interacted with each other in affecting performance. Trait test anxiety predicted performance only in a diagnostic condition that prevented stereotype threat by stereotype denial. A state measure of…

  8. 40 CFR 63.1546 - Performance testing.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 13 2012-07-01 2012-07-01 false Performance testing. 63.1546 Section... Emission Standards for Hazardous Air Pollutants for Primary Lead Smelting § 63.1546 Performance testing. (a... performance test shall consist of at least three runs. For each test run with Method 12 or Method 29, the...

  9. Performance on a work-simulating firefighter test versus approved laboratory tests for firefighters and applicants.

    PubMed

    von Heimburg, Erna; Medbø, Jon Ingulf; Sandsund, Mariann; Reinertsen, Randi Eidsmo

    2013-01-01

    Firefighters must meet minimum physical demands. The Norwegian Labour Inspection Authority (NLIA) has approved a standardised treadmill walking test and 3 simple strength tests for smoke divers. The results of the Trondheim test were compared with those of the NLIA tests taking into account possible effects of age, experience level and gender. Four groups of participants took part in the tests: 19 young experienced firefighters, 24 senior male firefighters and inexperienced applicants, 12 male and 8 female. Oxygen uptake (VO2) at exhaustion rose linearly by the duration of the treadmill test. Time spent on the Trondheim test was closely related to performance time and peak VO2 on the treadmill test. Senior experienced firefighters did not perform better than equally fit young applicants. However, female applicants performed poorer on the Trondheim test than on the treadmill test. Performance on the Trondheim test was not closely related to muscle strength beyond a minimum. CONCLUSION. Firefighters completing the Trondheim test in under 19 min fit the requirements of the NLIA treadmill test. The Trondheim test can be used as an alternative to the NLIA tests for testing aerobic fitness but not for muscular strength. Women's result of the Trondheim test were poorer than the results of the NLIA treadmill test, probably because of their lower body mass.

  10. Indoor test for thermal performance of the Sunmaster evacuated tube (liquid) solar collector

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The test procedures used to obtain the thermal performance data for a solar collector under simulated conditions are presented. Tests included a stagnation test, a time constant test, a thermal efficiency test, an incident angle modifier test, and a hot fill test. All tests were performed at ambient conditions and the transient effect and the incident angle effect on the collector were determined. The solar collector is a water working fluid type.

  11. Development, construct validity and test-retest reliability of a field-based wheelchair mobility performance test for wheelchair basketball.

    PubMed

    de Witte, Annemarie M H; Hoozemans, Marco J M; Berger, Monique A M; van der Slikke, Rienk M A; van der Woude, Lucas H V; Veeger, Dirkjan H E J

    2018-01-01

    The aim of this study was to develop and describe a wheelchair mobility performance test in wheelchair basketball and to assess its construct validity and reliability. To mimic mobility performance of wheelchair basketball matches in a standardised manner, a test was designed based on observation of wheelchair basketball matches and expert judgement. Forty-six players performed the test to determine its validity and 23 players performed the test twice for reliability. Independent-samples t-tests were used to assess whether the times needed to complete the test were different for classifications, playing standards and sex. Intraclass correlation coefficients (ICC) were calculated to quantify reliability of performance times. Males performed better than females (P < 0.001, effect size [ES] = -1.26) and international men performed better than national men (P < 0.001, ES = -1.62). Performance time of low (≤2.5) and high (≥3.0) classification players was borderline not significant with a moderate ES (P = 0.06, ES = 0.58). The reliability was excellent for overall performance time (ICC = 0.95). These results show that the test can be used as a standardised mobility performance test to validly and reliably assess the capacity in mobility performance of elite wheelchair basketball athletes. Furthermore, the described methodology of development is recommended for use in other sports to develop sport-specific tests.

  12. Performance Test on Polymer Waste Form - 12137

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Se Yup

    Polymer solidification was attempted to produce stable waste form for the boric acid concentrates and the dewatered spent resins. The polymer mixture was directly injected into the mold or drum which was packed with the boric acid concentrates and the dewatered spent resins, respectively. The waste form was produced by entirely curing the polymer mixture. A series of performance tests was conducted including compressive strength test, water immersion test, leach test, thermal stability test, irradiation stability test and biodegradation stability test for the polymer waste forms. From the results of the performance tests for the polymer waste forms, it ismore » believed that the polymer waste form is very stable and can satisfy the acceptance criteria for permanent disposal. At present, performance tests with full scale polymer waste forms are being carried out in order to obtain qualification certificate by the regulatory institute in Korea. Polymer waste forms were prepared with the surrogate of boric acid concentrates and the surrogate of spent ion exchange resins respectively. Waste forms were also made in lab scale and in full scale. Lab. scale waste forms were directly subjected to a series of the performance tests. In the case of full scale waste form, the test specimens for the performance test were taken from a part of waste form by coring. A series of performance tests was conducted including compressive strength test, thermal stability test, irradiation stability test and biodegradation stability test, water immersion test, leach test, and free standing water for the polymer waste forms. In addition, a fire resistance test was performed on the waste forms by the requirement of the regulatory institute in Korea. Every polymer waste forms containing the boric acid concentrates and the spent ion exchange resins had exhibited excellent structural integrity of more than 27.58 MPa (4,000 psi) of compressive strength. On thermal stability testing, biodegradation testing and water immersion testing, no degradation was observed in the waste forms. Also, by measuring the compressive strength after these tests, it was confirmed that the structural integrity was still retained. A leach test was performed by using non radioactive cobalt, cesium and strontium. The leaching of cobalt, cesium and strontium from the polymer waste forms was very low. Also, the polymer waste forms were found to possess adequate fire resistance. From the results of the performance tests, it is believed that the polymer waste form is very stable and can satisfy the acceptance criteria for permanent disposal. At present, Performance tests with full scale polymer waste forms are on-going in order to obtain qualification certificate by the regulatory institute in Korea. (authors)« less

  13. Test anxiety in relation to measures of cognitive and intellectual functioning.

    PubMed

    Gass, Carlton S; Curiel, Rosie E

    2011-08-01

    The potential impact of test anxiety on cognitive testing was examined in a sample of 300 predominantly male veteran referrals who were administered a comprehensive neuropsychological test battery. Exclusionary criteria included failure on effort testing (n= 14). Level of test anxiety was significantly related to performance on the WAIS-III Working Memory Index (r = -.343, p < .001) but not to scores on the Processing Speed, Perceptual Organization, or Verbal Comprehension indexes. Test anxiety was not related to a global index of neuropsychological performance on the HRNES-R (Average Impairment Scale). Level of education had a collinear relationship with test anxiety in predicting cognitive test performance. Regression analyses revealed a more prominent role for education, indicating the possibility that test anxiety may be a reaction to, more than a cause of, deficient working memory performance. These results suggest that clinicians who use these particular tests should be reluctant to attribute poor test performance to anxiety that occurs during the testing process.

  14. Electrical Characterization of the RCA CDP1822SD Random Access Memory, Volume 1, Appendix a

    NASA Technical Reports Server (NTRS)

    Klute, A.

    1979-01-01

    Electrical characteristization tests were performed on 35 RCA CDP1822SD, 256-by-4-bit, CMOS, random access memories. The tests included three functional tests, AC and DC parametric tests, a series of schmoo plots, rise/fall time screening, and a data retention test. All tests were performed on an automated IC test system with temperatures controlled by a thermal airstream unit. All the functional tests, the data retention test, and the AC and DC parametric tests were performed at ambient temperatures of 25 C, -20 C, -55 C, 85 C, and 125 C. The schmoo plots were performed at ambient temperatures of 25 C, -55 C, and 125 C. The data retention test was performed at 25 C. Five devices failed one or more functional tests and four of these devices failed to meet the expected limits of a number of AC parametric tests. Some of the schmoo plots indicated a small degree of interaction between parameters.

  15. Strapdown gyro test program

    NASA Technical Reports Server (NTRS)

    Irvine, R. B.; Vanalstine, R.

    1977-01-01

    The power spectral noise characteristic performance of the Teledyne two-degree-of-freedom dry tuned gimbal gyroscope was determined. Tests were conducted using a current configuration SDG-5 gyro in conjunction with test equipment with minor modification. Long term bias stability tests were conducted as well as some first difference performance tests. The gyro, test equipment, and the tests performed are described. Results are presented.

  16. Performance testing of EVs in the EPRI/TVA EV program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Driggans, R.L.

    1983-01-01

    Performance testing has been completed on four electric vehicles: the Grumman-Olson Kubvan, SCT Electric (VW) Pickup, Jet Industries Electrica, and VW Electrotransporter Bus. The tests performed included vehicle dc energy consumption and driving range at constant speeds and on the SAE J227a C cycle, on-road driving range, hill climbing, maximum acceleration, top speed, and braking performance. Descriptions of the vehicles tested and comparisons of major performance parameters on all four vehicles are presented. This testing was performed at the TVA Electric Vehicle Test Facility.

  17. 40 CFR 63.1546 - Performance testing.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 13 2013-07-01 2012-07-01 true Performance testing. 63.1546 Section 63... Emission Standards for Hazardous Air Pollutants for Primary Lead Smelting § 63.1546 Performance testing. (a... performance test shall consist of at least three runs. For each test run with Method 12 or Method 29, the...

  18. Manufacture and evaluation of Li/BCX DD cells

    NASA Technical Reports Server (NTRS)

    Meyer, S.; Takeuchi, E.

    1990-01-01

    This project is divided into four main tasks: cell manufacture, acceptance, and lot certification of cells, performance testing of cells, and abuse testing of cells. Lithium/bromine chloride in thionyl chloride (Li/BCX) 149 DD cells (PN 3B2085-XA) were built according to the provisions of Electrochem Industries Quality Plan 17096. Acceptance and lot certification testing was performed according to NASA JSC Document EP5-83-025, Revision B. Acceptance testing included open circuit and load voltage check, visual examination, size and weight measurements, and high temperature exposure. Lot certification tests were performed for capacity performance and for performance under conditions of thermal and electrical abuse. These tests included 149 C exposure, capacity discharge, fuse check, high temperature exposure, high rate discharge, short circuit, vibration, and overdischarge testing. A quantity of 200 cells was delivered to Johnson Space Center for life test evaluation. A parametric evaluation of the capacity discharge of Li/BCX DD cells was performed over a variety of temperatures and discharge rates. This testing served to map the performance capability of the cell. Tests were also performed over a variety of electrical and thermal abuse conditions. Abuse tests included short circuit, charging, overdischarge, high temperature exposure, shock, and vibration.

  19. Identifying failure in a tree network of a parallel computer

    DOEpatents

    Archer, Charles J.; Pinnow, Kurt W.; Wallenfelt, Brian P.

    2010-08-24

    Methods, parallel computers, and products are provided for identifying failure in a tree network of a parallel computer. The parallel computer includes one or more processing sets including an I/O node and a plurality of compute nodes. For each processing set embodiments include selecting a set of test compute nodes, the test compute nodes being a subset of the compute nodes of the processing set; measuring the performance of the I/O node of the processing set; measuring the performance of the selected set of test compute nodes; calculating a current test value in dependence upon the measured performance of the I/O node of the processing set, the measured performance of the set of test compute nodes, and a predetermined value for I/O node performance; and comparing the current test value with a predetermined tree performance threshold. If the current test value is below the predetermined tree performance threshold, embodiments include selecting another set of test compute nodes. If the current test value is not below the predetermined tree performance threshold, embodiments include selecting from the test compute nodes one or more potential problem nodes and testing individually potential problem nodes and links to potential problem nodes.

  20. A better state-of-mind: deep breathing reduces state anxiety and enhances test performance through regulating test cognitions in children.

    PubMed

    Khng, Kiat Hui

    2017-11-01

    A pre-test/post-test, intervention-versus-control experimental design was used to examine the effects, mechanisms and moderators of deep breathing on state anxiety and test performance in 122 Primary 5 students. Taking deep breaths before a timed math test significantly reduced self-reported feelings of anxiety and improved test performance. There was a statistical trend towards greater effectiveness in reducing state anxiety for boys compared to girls, and in enhancing test performance for students with higher autonomic reactivity in test-like situations. The latter moderation was significant when comparing high-versus-low autonomic reactivity groups. Mediation analyses suggest that deep breathing reduces state anxiety in test-like situations, creating a better state-of-mind by enhancing the regulation of adaptive-maladaptive thoughts during the test, allowing for better performance. The quick and simple technique can be easily learnt and effectively applied by most children to immediately alleviate some of the adverse effects of test anxiety on psychological well-being and academic performance.

  1. High School Students' Performance on Vandenberg's Mental Rotations Test: Art Ability, Gender, Activities, Academic Performance, Strategies, and Ease of Taking the Test.

    ERIC Educational Resources Information Center

    Gurny, Helen Graham

    This study tested whether mental rotation performance of 186 high school students (80 males and 106 females) in grades 9 through 12 in art and nonart classes on Vandenbergs Mental Rotations test (S. Vandenberg and Kuse, 1978) was affected by gender, visual-spatial activities, strategies used while performing the test, and the ease of test taking.…

  2. Expectancy of an open-book test decreases performance on a delayed closed-book test.

    PubMed

    Agarwal, Pooja K; Roediger, Henry L

    2011-11-01

    Two experiments examined the influence of practice with, and the expectancy of, open-book tests (students viewed studied material while taking the test) versus closed-book tests (students completed the test without viewing the studied material) on delayed retention and transfer. Using GRE materials specifically designed for open-book testing, participants studied passages and then took initial open- or closed-book tests. Open-book testing led to better initial performance than closed-book testing, but on a delayed criterial (closed-book) test both types of testing produced similar retention after a two-day delay in Experiment 1. In Experiment 2 participants were informed in advance about the type of delayed criterial test to expect (open- or closed-book). Expecting an open-book test (relative to a closed-book test) decreased participants' time spent studying and their delayed test performance on closed-book comprehension and transfer tests, demonstrating that test expectancy can influence long-term learning. Expectancy of open-book tests may impair long-term retention and transfer compared to closed-book tests, despite superior initial performance on open-book tests and students' preference for open-book tests.

  3. Evaluating Maintenance Performance: Test Administrator's Manual and Test Subject's Instructions for Criterion Referenced Job Task Performance Tests for Electronic Maintenance. Final Report.

    ERIC Educational Resources Information Center

    Shriver, Edgar L.; And Others

    This document furnishes a complete copy of the Test Subject's Instructions and the Test Administrator's Handbook for a battery of criterion referenced Job Task Performance Tests (JTPT) for electronic maintenance. General information is provided on soldering, Radar Set AN/APN-147(v), Radar Set Special Equipment, Radar Set Bench Test Set-Up, and…

  4. 40 CFR Table 6 to Subpart Wwww of... - Basic Requirements for Performance Tests, Performance Evaluations, and Design Evaluations for New...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control... Performance Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control Devices As required in § 63.5850 you must conduct performance tests, performance evaluations, and...

  5. 40 CFR Table 6 to Subpart Wwww of... - Basic Requirements for Performance Tests, Performance Evaluations, and Design Evaluations for New...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control... Performance Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control Devices As required in § 63.5850 you must conduct performance tests, performance evaluations, and...

  6. 40 CFR Table 6 to Subpart Wwww of... - Basic Requirements for Performance Tests, Performance Evaluations, and Design Evaluations for New...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control... Performance Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control Devices As required in § 63.5850 you must conduct performance tests, performance evaluations, and...

  7. Small passenger car transmission test-Chevrolet 200 transmission

    NASA Technical Reports Server (NTRS)

    Bujold, M. P.

    1980-01-01

    The small passenger car transmission was tested to supply electric vehicle manufacturers with technical information regarding the performance of commerically available transmissions which would enable them to design a more energy efficient vehicle. With this information the manufacturers could estimate vehicle driving range as well as speed and torque requirements for specific road load performance characteristics. A 1979 Chevrolet Model 200 automatic transmission was tested per a passenger car automatic transmission test code (SAE J651b) which required drive performance, coast performance, and no load test conditions. The transmission attained maximum efficiencies in the mid-eighty percent range for both drive performance tests and coast performance tests. Torque, speed and efficiency curves map the complete performance characteristics for Chevrolet Model 200 transmission.

  8. Pad stress tests with increasing load for the diagnosis of stress urinary incontinence.

    PubMed

    Rimstad, Liv; Larsen, Elsa Skjønhaug; Schiøtz, Hjalmar A; Kulseng-Hanssen, Sigurd

    2014-09-01

    The aim of the study was to test the ability of pad stress tests with increasing load (supine, jumping on the floor, and jumping on a trampoline) to document stress incontinence in subjectively stress incontinent women. In this prospective study 147 subjectively stress and mixed incontinent women performed consecutively the three pad stress tests with a bladder volume of 300 ml. Nineteen women performed a second trampoline pad stress test to test repeatability of the test. Nine continent women performed a trampoline pad stress test in order to determine if subjectively continent women would leak during the test. Seventy-two women (49%) leaked during the supine, 136 (93%) leaked during the jumping, and 146 (99%) leaked during the trampoline pad stress test. The differences between pad stress tests were significant with P < 0.005. Correlation between the two trampoline pad stress tests was high at 0.8. None of the nine continent women leaked during the trampoline pad stress test. The supine pad stress test has low sensitivity and is therefore often falsely negative. The jumping pad stress test is a simple test to perform and is satisfactory for everyday use. Subjectively stress incontinent women who do not leak during the jumping pad stress test may perform a trampoline pad stress test to document stress incontinence. The trampoline pad stress test is also simple to perform and detected leakage in 91% of the women who did not leak during the jumping pad stress test. © 2013 Wiley Periodicals, Inc.

  9. 40 CFR 60.3027 - How do I conduct the initial and annual performance test?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 26A of appendix A of this part must be used. (ii) The post-test moisture removal procedure described... performance test? 60.3027 Section 60.3027 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED..., 2004 Model Rule-Performance Testing § 60.3027 How do I conduct the initial and annual performance test...

  10. 40 CFR 60.2922 - How do I conduct the initial and annual performance test?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 26A of appendix A of this part must be used. (ii) The post-test moisture removal procedure described... performance test? 60.2922 Section 60.2922 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Qualification Performance Testing § 60.2922 How do I conduct the initial and annual performance test? (a) All...

  11. 40 CFR 60.3027 - How do I conduct the initial and annual performance test?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 26A of appendix A of this part must be used. (ii) The post-test moisture removal procedure described... performance test? 60.3027 Section 60.3027 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED..., 2004 Model Rule-Performance Testing § 60.3027 How do I conduct the initial and annual performance test...

  12. 40 CFR 60.3027 - How do I conduct the initial and annual performance test?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 26A of appendix A of this part must be used. (ii) The post-test moisture removal procedure described... performance test? 60.3027 Section 60.3027 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED..., 2004 Model Rule-Performance Testing § 60.3027 How do I conduct the initial and annual performance test...

  13. 40 CFR 60.3027 - How do I conduct the initial and annual performance test?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 26A of appendix A of this part must be used. (ii) The post-test moisture removal procedure described... performance test? 60.3027 Section 60.3027 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED..., 2004 Model Rule-Performance Testing § 60.3027 How do I conduct the initial and annual performance test...

  14. 40 CFR 60.3027 - How do I conduct the initial and annual performance test?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 26A of appendix A of this part must be used. (ii) The post-test moisture removal procedure described... performance test? 60.3027 Section 60.3027 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED..., 2004 Model Rule-Performance Testing § 60.3027 How do I conduct the initial and annual performance test...

  15. 40 CFR 60.2922 - How do I conduct the initial and annual performance test?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 26A of appendix A of this part must be used. (ii) The post-test moisture removal procedure described... performance test? 60.2922 Section 60.2922 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Qualification Performance Testing § 60.2922 How do I conduct the initial and annual performance test? (a) All...

  16. 40 CFR 60.2922 - How do I conduct the initial and annual performance test?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 26A of appendix A of this part must be used. (ii) The post-test moisture removal procedure described... performance test? 60.2922 Section 60.2922 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Qualification Performance Testing § 60.2922 How do I conduct the initial and annual performance test? (a) All...

  17. 40 CFR 63.11212 - What stack tests and procedures must I use for the performance tests?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 15 2014-07-01 2014-07-01 false What stack tests and procedures must I use for the performance tests? 63.11212 Section 63.11212 Protection of Environment ENVIRONMENTAL... What stack tests and procedures must I use for the performance tests? (a) You must conduct all...

  18. 40 CFR 63.11212 - What stack tests and procedures must I use for the performance tests?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 14 2011-07-01 2011-07-01 false What stack tests and procedures must I use for the performance tests? 63.11212 Section 63.11212 Protection of Environment ENVIRONMENTAL... What stack tests and procedures must I use for the performance tests? (a) You must conduct all...

  19. 40 CFR 63.11212 - What stack tests and procedures must I use for the performance tests?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 15 2012-07-01 2012-07-01 false What stack tests and procedures must I use for the performance tests? 63.11212 Section 63.11212 Protection of Environment ENVIRONMENTAL... What stack tests and procedures must I use for the performance tests? (a) You must conduct all...

  20. 40 CFR 63.11212 - What stack tests and procedures must I use for the performance tests?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 15 2013-07-01 2013-07-01 false What stack tests and procedures must I use for the performance tests? 63.11212 Section 63.11212 Protection of Environment ENVIRONMENTAL... What stack tests and procedures must I use for the performance tests? (a) You must conduct all...

  1. 40 CFR 63.1161 - Performance testing and test methods.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Facilities and Hydrochloric Acid Regeneration Plants § 63.1161 Performance testing and test methods. (a...) Establishment of hydrochloric acid regeneration plant operating parameters. (1) During the performance test for hydrochloric acid regeneration plants, the owner or operator shall establish site-specific operating parameter...

  2. 40 CFR 63.1161 - Performance testing and test methods.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Facilities and Hydrochloric Acid Regeneration Plants § 63.1161 Performance testing and test methods. (a...) Establishment of hydrochloric acid regeneration plant operating parameters. (1) During the performance test for hydrochloric acid regeneration plants, the owner or operator shall establish site-specific operating parameter...

  3. 40 CFR 63.344 - Performance test requirements and test methods.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... blanket type fume suppressants are used to control chromium emissions from a hard chromium electroplating... National Emission Standards for Chromium Emissions From Hard and Decorative Chromium Electroplating and Chromium Anodizing Tanks § 63.344 Performance test requirements and test methods. (a) Performance test...

  4. 40 CFR 63.344 - Performance test requirements and test methods.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... blanket type fume suppressants are used to control chromium emissions from a hard chromium electroplating... National Emission Standards for Chromium Emissions From Hard and Decorative Chromium Electroplating and Chromium Anodizing Tanks § 63.344 Performance test requirements and test methods. (a) Performance test...

  5. 40 CFR 63.344 - Performance test requirements and test methods.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... blanket type fume suppressants are used to control chromium emissions from a hard chromium electroplating... National Emission Standards for Chromium Emissions From Hard and Decorative Chromium Electroplating and Chromium Anodizing Tanks § 63.344 Performance test requirements and test methods. (a) Performance test...

  6. 40 CFR 799.4360 - Tributyl phosphate.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... provisions also apply: (i) Animal selection. Testing shall be performed in laboratory rats. (ii) Duration of... apply: (i) Animal selection. Testing shall be performed in laboratory rats. (ii) Duration of testing...) Animal selection. Testing shall be performed in laboratory rats. (ii) Duration of testing. Animals shall...

  7. Integrated Advance Microwave Sounding Unit-A (AMSU-A). Performance Verification Report: EOS AMSU-A1 and AMSU-A2 Receivers Assemblies

    NASA Technical Reports Server (NTRS)

    2000-01-01

    This test report presents the test data of the EOS AMSU-A Flight Model No.1 (FM-1) receiver subsystem. The tests are performed per the Acceptance Test Procedure for the AMSU-A Reseiver Subsystem, AE-26002/6A. The functional performance tests are conducted either at the component or subsystem level. While the component-level tests are performed over the entire operating temperature range predicted by thermal analysis, the subsystem-level test are conducted at ambient temperature only.

  8. Testing the performance of microbiological safety cabinets used in microbiology laboratories in South Korea.

    PubMed

    Hwang, S H; Yi, T W; Cho, K H; Lee, I M; Yoon, C S

    2011-09-01

    To test a performance of the microbiological safety cabinets (MSCs) according to the type of MSCs in microbial laboratories. Tests were carried out to assess the performance of 31 MSCs in 14 different facilities, including six different biological test laboratories in six hospitals and eight different laboratories in three universities. The following tests were performed on the MSCs: the downflow test, intake velocity test, high-efficiency particulate air filter leak test and the airflow smoke pattern test. These performance tests were carried out in accordance with the standard procedures. Only 23% of Class II A1 (8), A2 (19) and unknown MSCs (4) passed these performance tests. The main reasons for the failure of MSCs were inappropriate intake velocity (65%), leakage in the HEPA filter sealing (50%), unbalanced airflow smoke pattern in the cabinets (39%) and inappropriate downflow (27%). This study showed that routine checks of MSCs are important to detect and strengthen the weak spots that frequently develop, as observed during the evaluation of the MSCs of various institutions. Routine evaluation and maintenance of MSCs are critical for optimizing performance. © 2011 The Authors. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.

  9. 40 CFR Table 6 to Subpart Wwww of... - Basic Requirements for Performance Tests, Performance Evaluations, and Design Evaluations for New...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control Devices As required in § 63.5850 you must conduct performance tests, performance evaluations, and design...

  10. 40 CFR Table 6 to Subpart Wwww of... - Basic Requirements for Performance Tests, Performance Evaluations, and Design Evaluations for New...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control Devices As required in § 63.5850 you must conduct performance tests, performance evaluations, and design...

  11. 40 CFR 600.208-12 - Calculation of FTP-based and HFET-based fuel economy, CO2 emissions, and carbon-related exhaust...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., and carbon-related exhaust emissions from the tests performed using gasoline or diesel test fuel. (ii... from the tests performed using alcohol or natural gas test fuel. (b) For each model type, as determined... from the tests performed using gasoline or diesel test fuel. (ii) Calculate the city, highway, and...

  12. 40 CFR 600.208-12 - Calculation of FTP-based and HFET-based fuel economy, CO2 emissions, and carbon-related exhaust...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., and carbon-related exhaust emissions from the tests performed using gasoline or diesel test fuel. (ii... from the tests performed using alcohol or natural gas test fuel. (b) For each model type, as determined... from the tests performed using gasoline or diesel test fuel. (ii) Calculate the city, highway, and...

  13. 40 CFR 600.208-12 - Calculation of FTP-based and HFET-based fuel economy, CO2 emissions, and carbon-related exhaust...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., and carbon-related exhaust emissions from the tests performed using gasoline or diesel test fuel. (ii... from the tests performed using alcohol or natural gas test fuel. (b) For each model type, as determined... from the tests performed using gasoline or diesel test fuel. (ii) Calculate the city, highway, and...

  14. Neurocognitive performance and symptom profiles of Spanish-speaking Hispanic athletes on the ImPACT test.

    PubMed

    Ott, Summer; Schatz, Philip; Solomon, Gary; Ryan, Joseph J

    2014-03-01

    This study documented baseline neurocognitive performance of 23,815 athletes on the Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) test. Specifically, 9,733 Hispanic, Spanish-speaking athletes who completed the ImPACT test in English and 2,087 Hispanic, Spanish-speaking athletes who completed the test in Spanish were compared with 11,955 English-speaking athletes who completed the test in English. Athletes were assigned to age groups (13-15, 16-18). Results revealed a significant effect of language group (p < .001; partial η(2) = 0.06) and age (p < .001; partial η(2) = 0.01) on test performance. Younger athletes performed more poorly than older athletes, and Spanish-speaking athletes completing the test in Spanish scored more poorly than Spanish-speaking and English-speaking athletes completing the test in English, on all Composite scores and Total Symptom scores. Spanish-speaking athletes completing the test in English also performed more poorly than English-speaking athletes completing the test in English on three Composite scores. These differences in performance and reported symptoms highlight the need for caution in interpreting ImPACT test data for Hispanic Americans.

  15. Fluid infusion system

    NASA Technical Reports Server (NTRS)

    1974-01-01

    Performance testing carried out in the development of the prototype zero-g fluid infusion system is described and summarized. Engineering tests were performed in the course of development, both on the original breadboard device and on the prototype system. This testing was aimed at establishing baseline system performance parameters and facilitating improvements. Acceptance testing was then performed on the prototype system to verify functional performance. Acceptance testing included a demonstration of the fluid infusion system on a laboratory animal.

  16. Functional performance testing of the hip in athletes: a systematic review for reliability and validity.

    PubMed

    Kivlan, Benjamin R; Martin, Robroy L

    2012-08-01

    The purpose of this study was to systematically review the literature for functional performance tests with evidence of reliability and validity that could be used for a young, athletic population with hip dysfunction. A search of PubMed and SPORTDiscus databases were performed to identify movement, balance, hop/jump, or agility functional performance tests from the current peer-reviewed literature used to assess function of the hip in young, athletic subjects. The single-leg stance, deep squat, single-leg squat, and star excursion balance tests (SEBT) demonstrated evidence of validity and normative data for score interpretation. The single-leg stance test and SEBT have evidence of validity with association to hip abductor function. The deep squat test demonstrated evidence as a functional performance test for evaluating femoroacetabular impingement. Hop/Jump tests and agility tests have no reported evidence of reliability or validity in a population of subjects with hip pathology. Use of functional performance tests in the assessment of hip dysfunction has not been well established in the current literature. Diminished squat depth and provocation of pain during the single-leg balance test have been associated with patients diagnosed with FAI and gluteal tendinopathy, respectively. The SEBT and single-leg squat tests provided evidence of convergent validity through an analysis of kinematics and muscle function in normal subjects. Reliability of functional performance tests have not been established on patients with hip dysfunction. Further study is needed to establish reliability and validity of functional performance tests that can be used in a young, athletic population with hip dysfunction. 2b (Systematic Review of Literature).

  17. The Concept of Performance Levels in Criterion-Referenced Assessment.

    ERIC Educational Resources Information Center

    Hewitson, Mal

    The concept of performance levels in criterion-referenced assessment is explored by applying the idea to different types of tests commonly used in schools, mastery tests (including diagnostic tests) and achievement tests. In mastery tests, a threshold performance standard must be established for each criterion. Attainment of this threshold…

  18. Motivation and Test Anxiety in Test Performance across Three Testing Contexts: The CAEL, CET, and GEPT

    ERIC Educational Resources Information Center

    Cheng, Liying; Klinger, Don; Fox, Janna; Doe, Christine; Jin, Yan; Wu, Jessica

    2014-01-01

    This study examined test-takers' motivation, test anxiety, and test performance across a range of social and educational contexts in three high-stakes language tests: the Canadian Academic English Language (CAEL) Assessment in Canada, the College English Test (CET) in the People's Republic of China, and the General English Proficiency Test (GEPT)…

  19. 47 CFR 2.1509 - Environmental and duration tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... above tests are to be performed on the same test unit. The tests in § 2.1509 (f) through (i) may be run... modulation characteristic tests in § 2.1513 of this part. Step (3) Perform the spectral tests in § 2.1515 of... extent possible for this test. (f) Float free and activation test. This test is required only for Class A...

  20. Spatial learning and psychomotor performance of C57BL/6 mice: age sensitivity and reliability of individual differences.

    PubMed

    de Fiebre, Nancyellen C; Sumien, Nathalie; Forster, Michael J; de Fiebre, Christopher M

    2006-09-01

    Two tests often used in aging research, the elevated path test and the Morris water maze test, were examined for their application to the study of brain aging in a large sample of C57BL/6JNia mice. Specifically, these studies assessed: (1) sensitivity to age and the degree of interrelatedness among different behavioral measures derived from these tests, (2) the effect of age on variation in the measurements, and (3) the reliability of individual differences in performance on the tests. Both tests detected age-related deficits in group performance that occurred independently of each other. However, analysis of data obtained on the Morris water maze test revealed three relatively independent components of cognitive performance. Performance in initial acquisition of spatial learning in the Morris maze was not highly correlated with performance during reversal learning (when mice were required to learn a new spatial location), whereas performance in both of those phases was independent of spatial performance assessed during a single probe trial administered at the end of acquisition training. Moreover, impaired performance during initial acquisition could be detected at an earlier age than impairments in reversal learning. There were modest but significant age-related increases in the variance of both elevated path test scores and in several measures of learning in the Morris maze test. Analysis of test scores of mice across repeated testing sessions confirmed reliability of the measurements obtained for cognitive and psychomotor function. Power calculations confirmed that there are sufficiently large age-related differences in elevated path test performance, relative to within age variability, to render this test useful for studies into the ability of an intervention to prevent or reverse age-related deficits in psychomotor performance. Power calculations indicated a need for larger sample sizes for detection of intervention effects on cognitive components of the Morris water maze test, at least when implemented at the ages tested in this study. Variability among old mice in both tests, including each of the various independent measures in the Morris maze, may be useful for elucidating the biological bases of different aspects of dysfunctional brain aging.

  1. Laboratory and clinical evaluation of on-site urine drug testing.

    PubMed

    Beck, Olof; Carlsson, Sten; Tusic, Marinela; Olsson, Robert; Franzen, Lisa; Hulten, Peter

    2014-11-01

    Products for on-site urine drug testing offer the possibility to perform screening for drugs of abuse directly at the point-of-care. This is a well-established routine in emergency and dependency clinics but further evaluation of performance is needed due to inherent limitations with the available products. Urine drug testing by an on-site product was compared with routine laboratory methods. First, on-site testing was performed at the laboratory in addition to the routine method. Second, the on-site testing was performed at a dependency clinic and urine samples were subsequently sent to the laboratory for additional analytical investigation. The on-site testing products did not perform with assigned cut-off levels. The subjective reading between the presence of a spot (i.e. negative test result) being present or no spot (positive result) was difficult in 3.2% of the cases, and occurred for all parameters. The tests performed more accurately in drug negative samples (specificity 96%) but less accurately for detecting positives (sensitivity 79%). Of all incorrect results by the on-site test the proportion of false negatives was 42%. The overall agreement between on-site and laboratory testing was 95% in the laboratory study and 98% in the clinical study. Although a high degree of agreement was observed between on-site and routine laboratory urine drug testing, the performance of on-site testing was not acceptable due to significant number of false negative results. The limited sensitivity of on-site testing compared to laboratory testing reduces the applicability of these tests.

  2. Incorporating DNA Sequencing into Current Prenatal Screening Practice for Down's Syndrome

    PubMed Central

    Wald, Nicholas J.; Bestwick, Jonathan P.

    2013-01-01

    Background Prenatal screening for Down's syndrome is performed using biochemical and ultrasound markers measured in early pregnancy such as the Integrated test using first and second trimester markers. Recently, DNA sequencing methods have been introduced on free DNA in maternal plasma, yielding a high screening performance. These methods are expensive and there is a test failure rate. We determined the screening performance of merging the Integrated test with the newer DNA techniques in a protocol that substantially reduces the cost compared with universal DNA testing and still achieves high screening performance with no test failures. Methods Published data were used to model screening performance of a protocol in which all women receive the first stage of the Integrated test at about 11 weeks of pregnancy. On the basis of this higher risk women have reflex DNA testing and lower risk women as well as those with a failed DNA test complete the Integrated test at about 15 weeks. Results The overall detection rate was 95% with a 0.1% false-positive rate if 20% of women were selected to receive DNA testing. If all women had DNA testing the detection rate would be 3 to 4 percentage points higher with a false-positive rate 30 times greater if women with failed tests were treated as positive and offered a diagnostic amniocentesis, or 3 times greater if they had a second trimester screening test (Quadruple test) and treated as positive only if this were positive. The cost per women screened would be about one-fifth, compared with universal DNA testing, if the DNA test were 20 times the cost of the Integrated test. Conclusion The proposed screening protocol achieves a high screening performance without programme test failures and at a substantially lower cost than offering all women DNA testing. PMID:23527014

  3. 47 CFR 76.601 - Performance tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 4 2011-10-01 2011-10-01 false Performance tests. 76.601 Section 76.601... CABLE TELEVISION SERVICE Technical Standards § 76.601 Performance tests. (a) The operator of each cable... cable television system shall conduct complete performance tests of that system at least twice each...

  4. 47 CFR 76.601 - Performance tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 4 2012-10-01 2012-10-01 false Performance tests. 76.601 Section 76.601... CABLE TELEVISION SERVICE Technical Standards § 76.601 Performance tests. (a) The operator of each cable... cable television system shall conduct complete performance tests of that system at least twice each...

  5. 47 CFR 76.601 - Performance tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 4 2014-10-01 2014-10-01 false Performance tests. 76.601 Section 76.601... CABLE TELEVISION SERVICE Technical Standards § 76.601 Performance tests. (a) The operator of each cable... cable television system shall conduct complete performance tests of that system at least twice each...

  6. How Strong and Weak Readers Perform on the Developmental Eye Movement Test (DEM): Norms for Latvian School-Aged Children

    ERIC Educational Resources Information Center

    Serdjukova, Jelena; Ekimane, Lasma; Valeinis, Janis; Skilters, Jurgis; Krumina, Gunta

    2017-01-01

    The aim of our study was to determine DEM test performance norms for school-aged children in Latvia, assess how DEM test results correlate with children's reading rates, compare test performance between strong and weak readers. A modified DEM test and a newly developed reading test were administered to 1487 children during a screening survey. Our…

  7. Motivational and Cognitive Test-Taking Strategies and Their Influence on Test Performance in Mathematics

    ERIC Educational Resources Information Center

    Peng, Yun; Hong, Eunsook; Mason, Elsa

    2014-01-01

    A structural equation model of relationships among testing-related motivation variables (test value, effort, self-efficacy, and test anxiety), test-taking strategies (test tactics and metacognitive strategies), gender, and math test performance were examined with a sample of 10th graders (N = 438; 182 males and 256 females). In general, motivation…

  8. Solar thermal upper stage technology demonstrator liquid hydrogen storage and feed system test program

    NASA Astrophysics Data System (ADS)

    Cady, E. C.

    1997-01-01

    The Solar Thermal Upper Stage Technology Demonstrator (STUSTD) Liquid Hydrogen Storage and Feed System (LHSFS) Test Program is described. The test program consists of two principal phases. First, an engineering characterization phase includes tests performed to demonstrate and understand the expected tank performance. This includes fill and drain; baseline heat leak; active Thermodynamic Vent System (TVS); and flow tests. After the LHSFS performance is understood and performance characteristics are determined, a 30 day mission simulation test will be conducted. This test will simulate a 30 day transfer mission from low earth orbit (LEO) to geosynchronous equatorial orbit (GEO). Mission performance predictions, based on the results of the engineering characterization tests, will be used to correlate the results of the 30 day mission simulation.

  9. Occupational-Specific Strength Predicts Astronaut-Related Task Performance in a Weighted Suit.

    PubMed

    Taylor, Andrew; Kotarsky, Christopher J; Bond, Colin W; Hackney, Kyle J

    2018-01-01

    Future space missions beyond low Earth orbit will require deconditioned astronauts to perform occupationally relevant tasks within a planetary spacesuit. The prediction of time-to-completion (TTC) of astronaut tasks will be critical for crew safety, autonomous operations, and mission success. This exploratory study determined if the addition of task-specific strength testing to current standard lower body testing would enhance the prediction of TTC in a 1-G test battery. Eight healthy participants completed NASA lower body strength tests, occupationally specific strength tests, and performed six task simulations (hand drilling, construction wrenching, incline walking, collecting weighted samples, and dragging an unresponsive crewmember to safety) in a 48-kg weighted suit. The TTC for each task was recorded and summed to obtain a total TTC for the test battery. Linear regression was used to predict total TTC with two models: 1) NASA lower body strength tests; and 2) NASA lower body strength tests + occupationally specific strength tests. Total TTC of the test battery ranged from 20.2-44.5 min. The lower body strength test alone accounted for 61% of the variability in total TTC. The addition of hand drilling and wrenching strength tests accounted for 99% of the variability in total TTC. Adding occupationally specific strength tests (hand drilling and wrenching) to standard lower body strength tests successfully predicted total TTC in a performance test battery within a weighted suit. Future research should couple these strength tests with higher fidelity task simulations to determine the utility and efficacy of task performance prediction.Taylor A, Kotarsky CJ, Bond CW, Hackney KJ. Occupational-specific strength predicts astronaut-related task performance in a weighted suit. Aerosp Med Hum Perform. 2018; 89(1):58-62.

  10. Factors Contributing to Single- and Dual-Task Timed "Up & Go" Test Performance in Middle-Aged and Older Adults Who Are Active and Dwell in the Community.

    PubMed

    Chen, Hui-Ya; Tang, Pei-Fang

    2016-03-01

    Dual-task Timed "Up & Go" (TUG) tests are likely to have applications different from those of a single-task TUG test and may have different contributing factors. The purpose of this study was to compare factors contributing to performance on single- and dual-task TUG tests. This investigation was a cross-sectional study. Sixty-four adults who were more than 50 years of age and dwelled in the community were recruited. Interviews and physical examinations were performed to identify potential contributors to TUG test performance. The time to complete the single-task TUG test (TUGsingle) or the dual-task TUG test, which consisted of completing the TUG test while performing a serial subtraction task (TUGcognitive) or while carrying water (TUGmanual), was measured. Age, hip extensor strength, walking speed, general mental function, and Stroop scores for word and color were significantly associated with performance on all TUG tests. Hierarchical multiple regression models, without the input of walking speed, revealed different independent factors contributing to TUGsingle performance (Mini-Mental Status Examination score, β=-0.32), TUGmanual performance (age, β=0.35), and TUGcognitive performance (Stroop word score, β=-0.40; Mini-Mental Status Examination score, β=-0.31). At least 40% of the variance in the performance on the 3 TUG tests was not explained by common clinical measures, even when the factor of walking speed was considered. However, this study successfully identified some important factors contributing to performance on different TUG tests, and other studies have reported similar findings for single-task TUG test and dual-task gait performance. Although the TUGsingle and the TUGcognitive shared general mental function as a common factor, the TUGmanual was uniquely influenced by age and the TUGcognitive was uniquely influenced by focused attention. These results suggest that both common and unique factors contribute to performance on single- and dual-task TUG tests and suggest important applications of the combined use of the 3 TUG tests. © 2016 American Physical Therapy Association.

  11. Spelling for the Office. Competency Test Package. Office Occupations. Instructor's Guide.

    ERIC Educational Resources Information Center

    Hines, Donna

    This competency test package, one of a series of test packages for office occupations education, contains a list of performance objectives; a pool of objective questions matched with these performance objectives; a sample, 50-point objective test; and several performance test activities. The package also includes complete directions for the…

  12. Basic Skills for Word Processing. Competency Test Package. Office Occupations. Instructor's Guide.

    ERIC Educational Resources Information Center

    Hines, Donna

    This competency test package, one of a series of test packages for office occupations education, contains a list of performance objectives; a pool of objective questions matched with these performance objectives; a sample, 50-point objective test; and several performance test activities. The package also includes complete directions for the…

  13. Student Assessment System. Domain Referenced Tests. Cosmetology. Volume I: Skills. Georgia Vocational Education Program Articulation.

    ERIC Educational Resources Information Center

    Rice, Linda Maxwell; And Others

    These performance tests for the area of cosmetology consist of a sampling technique (domain referenced tests) which covers all the possible performance situations. When used in total, they may also serve as a comprehensive test. Introductory materials discuss domain referenced testing, determining the domains, and developing performance testing…

  14. 40 CFR 63.7515 - When must I conduct subsequent performance tests, fuel analyses, or tune-ups?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... performance tests, fuel analyses, or tune-ups? 63.7515 Section 63.7515 Protection of Environment ENVIRONMENTAL..., fuel analyses, or tune-ups? (a) You must conduct all applicable performance tests according to § 63... performance tests and the associated fuel analyses within 60 days after the completion of the performance...

  15. 40 CFR 63.7515 - When must I conduct subsequent performance tests, fuel analyses, or tune-ups?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... performance tests, fuel analyses, or tune-ups? 63.7515 Section 63.7515 Protection of Environment ENVIRONMENTAL..., fuel analyses, or tune-ups? (a) You must conduct all applicable performance tests according to § 63... performance tests and the associated fuel analyses within 60 days after the completion of the performance...

  16. Test anxiety, perfectionism, goal orientation, and academic performance.

    PubMed

    Eum, KoUn; Rice, Kenneth G

    2011-03-01

    Dimensions of perfectionism and goal orientation have been reported to have differential relationships with test anxiety. However, the degree of inter-relationship between different dimensions of perfectionism, the 2 × 2 model of goal orientations proposed by Elliot and McGregor, cognitive test anxiety, and academic performance indicators is not known. Based on data from 134 university students, we conducted correlation and regression analyses to test associations between adaptive and maladaptive perfectionism, four types of goal orientations, cognitive test anxiety, and two indicators of academic performance: proximal cognitive performance on a word list recall test and distal academic performance in terms of grade point average. Cognitive test anxiety was inversely associated with both performance indicators, and positively associated with maladaptive perfectionism and avoidance goal orientations. Adaptive and maladaptive perfectionism accounted for significant variance in cognitive test anxiety after controlling for approach and avoidance goal orientations. Overall, nearly 50% of the variance in cognitive test anxiety could be attributed to gender, goal orientations, and perfectionism. Results suggested that students who are highly test anxious are likely to be women who endorse avoidance goal orientations and are maladaptively perfectionistic.

  17. Strain energy release rate as a function of temperature and preloading history utilizing the edge delamination fatique test method

    NASA Technical Reports Server (NTRS)

    Zimmerman, Richard S.; Adams, Donald F.

    1989-01-01

    Static laminate and tension-tension fatigue tests of IM7/8551-7 composite materials was performed. The Edge Delamination Test (EDT) was utilized to evaluate the temperature and preloading history effect on the critical strain energy release rate. Static and fatigue testing was performed at room temperature and 180 F (82 C). Three preloading schemes were used to precondition fatigue test specimens prior to performing the normal tension-tension fatigue EDT testing. Computer software was written to perform all fatigue testing while monitoring the dynamic modulus to detect the onset of delamination and record the test information for later retrieval and reduction.

  18. Test Takers' Performance Appraisals, Appraisal Calibration, and Cognitive and Metacognitive Strategy Use

    ERIC Educational Resources Information Center

    Phakiti, Aek

    2016-01-01

    The current study explores the nature and relationships among test takers' performance appraisals, appraisal calibration, and reported cognitive and metacognitive strategy use in a language test situation. Performance appraisals are executive processes of strategic competence for judging test performance (e.g., evaluating the correctness or…

  19. 42 CFR 493.1423 - Standard; Testing personnel qualifications.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 5 2013-10-01 2013-10-01 false Standard; Testing personnel qualifications. 493... Testing Laboratories Performing Moderate Complexity Testing § 493.1423 Standard; Testing personnel qualifications. Each individual performing moderate complexity testing must— (a) Possess a current license issued...

  20. 42 CFR 493.1423 - Standard; Testing personnel qualifications.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Standard; Testing personnel qualifications. 493... Testing Laboratories Performing Moderate Complexity Testing § 493.1423 Standard; Testing personnel qualifications. Each individual performing moderate complexity testing must— (a) Possess a current license issued...

  1. 42 CFR 493.1423 - Standard; Testing personnel qualifications.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 5 2014-10-01 2014-10-01 false Standard; Testing personnel qualifications. 493... Testing Laboratories Performing Moderate Complexity Testing § 493.1423 Standard; Testing personnel qualifications. Each individual performing moderate complexity testing must— (a) Possess a current license issued...

  2. 42 CFR 493.1423 - Standard; Testing personnel qualifications.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 5 2012-10-01 2012-10-01 false Standard; Testing personnel qualifications. 493... Testing Laboratories Performing Moderate Complexity Testing § 493.1423 Standard; Testing personnel qualifications. Each individual performing moderate complexity testing must— (a) Possess a current license issued...

  3. Oscillating-flow regenerator test rig

    NASA Technical Reports Server (NTRS)

    Wood, J. G.; Gedeon, D. R.

    1994-01-01

    This report summarizes work performed in setting up and performing tests on a regenerator test rig. An earlier status report presented test results, together with heat transfer correlations, for four regenerator samples (two woven screen samples and two felt metal samples). Lessons learned from this testing led to improvements to the experimental setup, mainly instrumentation as well as to the test procedure. Given funding and time constraints for this project it was decided to complete as much testing as possible while the rig was set up and operational, and to forego final data reduction and analysis until later. Additional testing was performed on several of the previously tested samples as well an on five newly fabricated samples. The following report is a summary of the work performed at OU, with many of the final test results included in raw data form.

  4. Do candidate reactions relate to job performance or affect criterion-related validity? A multistudy investigation of relations among reactions, selection test scores, and job performance.

    PubMed

    McCarthy, Julie M; Van Iddekinge, Chad H; Lievens, Filip; Kung, Mei-Chuan; Sinar, Evan F; Campion, Michael A

    2013-09-01

    Considerable evidence suggests that how candidates react to selection procedures can affect their test performance and their attitudes toward the hiring organization (e.g., recommending the firm to others). However, very few studies of candidate reactions have examined one of the outcomes organizations care most about: job performance. We attempt to address this gap by developing and testing a conceptual framework that delineates whether and how candidate reactions might influence job performance. We accomplish this objective using data from 4 studies (total N = 6,480), 6 selection procedures (personality tests, job knowledge tests, cognitive ability tests, work samples, situational judgment tests, and a selection inventory), 5 key candidate reactions (anxiety, motivation, belief in tests, self-efficacy, and procedural justice), 2 contexts (industry and education), 3 continents (North America, South America, and Europe), 2 study designs (predictive and concurrent), and 4 occupational areas (medical, sales, customer service, and technological). Consistent with previous research, candidate reactions were related to test scores, and test scores were related to job performance. Further, there was some evidence that reactions affected performance indirectly through their influence on test scores. Finally, in no cases did candidate reactions affect the prediction of job performance by increasing or decreasing the criterion-related validity of test scores. Implications of these findings and avenues for future research are discussed. PsycINFO Database Record (c) 2013 APA, all rights reserved

  5. Predictive validity of pre-admission assessments on medical student performance.

    PubMed

    Dabaliz, Al-Awwab; Kaadan, Samy; Dabbagh, M Marwan; Barakat, Abdulaziz; Shareef, Mohammad Abrar; Al-Tannir, Mohamad; Obeidat, Akef; Mohamed, Ayman

    2017-11-24

    To examine the predictive validity of pre-admission variables on students' performance in a medical school in Saudi Arabia. In this retrospective study, we collected admission and college performance data for 737 students in preclinical and clinical years. Data included high school scores and other standardized test scores, such as those of the National Achievement Test and the General Aptitude Test. Additionally, we included the scores of the Test of English as a Foreign Language (TOEFL) and the International English Language Testing System (IELTS) exams. Those datasets were then compared with college performance indicators, namely the cumulative Grade Point Average (cGPA) and progress test, using multivariate linear regression analysis. In preclinical years, both the National Achievement Test (p=0.04, B=0.08) and TOEFL (p=0.017, B=0.01) scores were positive predictors of cGPA, whereas the General Aptitude Test (p=0.048, B=-0.05) negatively predicted cGPA. Moreover, none of the pre-admission variables were predictive of progress test performance in the same group. On the other hand, none of the pre-admission variables were predictive of cGPA in clinical years. Overall, cGPA strongly predict-ed students' progress test performance (p<0.001 and B=19.02). Only the National Achievement Test and TOEFL significantly predicted performance in preclinical years. However, these variables do not predict progress test performance, meaning that they do not predict the functional knowledge reflected in the progress test. We report various strengths and deficiencies in the current medical college admission criteria, and call for employing more sensitive and valid ones that predict student performance and functional knowledge, especially in the clinical years.

  6. Predictive validity of pre-admission assessments on medical student performance

    PubMed Central

    Dabaliz, Al-Awwab; Kaadan, Samy; Dabbagh, M. Marwan; Barakat, Abdulaziz; Shareef, Mohammad Abrar; Al-Tannir, Mohamad; Obeidat, Akef

    2017-01-01

    Objectives To examine the predictive validity of pre-admission variables on students’ performance in a medical school in Saudi Arabia.  Methods In this retrospective study, we collected admission and college performance data for 737 students in preclinical and clinical years. Data included high school scores and other standardized test scores, such as those of the National Achievement Test and the General Aptitude Test. Additionally, we included the scores of the Test of English as a Foreign Language (TOEFL) and the International English Language Testing System (IELTS) exams. Those datasets were then compared with college performance indicators, namely the cumulative Grade Point Average (cGPA) and progress test, using multivariate linear regression analysis. Results In preclinical years, both the National Achievement Test (p=0.04, B=0.08) and TOEFL (p=0.017, B=0.01) scores were positive predictors of cGPA, whereas the General Aptitude Test (p=0.048, B=-0.05) negatively predicted cGPA. Moreover, none of the pre-admission variables were predictive of progress test performance in the same group. On the other hand, none of the pre-admission variables were predictive of cGPA in clinical years. Overall, cGPA strongly predict-ed students’ progress test performance (p<0.001 and B=19.02). Conclusions Only the National Achievement Test and TOEFL significantly predicted performance in preclinical years. However, these variables do not predict progress test performance, meaning that they do not predict the functional knowledge reflected in the progress test. We report various strengths and deficiencies in the current medical college admission criteria, and call for employing more sensitive and valid ones that predict student performance and functional knowledge, especially in the clinical years. PMID:29176032

  7. Comparison of physical therapy anatomy performance and anxiety scores in timed and untimed practical tests.

    PubMed

    Schwartz, Sarah M; Evans, Cathy; Agur, Anne M R

    2015-01-01

    Students in health care professional programs face many stressful tests that determine successful completion of their program. Test anxiety during these high stakes examinations can affect working memory and lead to poor outcomes. Methods of decreasing test anxiety include lengthening the time available to complete examinations or evaluating students using untimed examinations. There is currently no consensus in the literature regarding whether untimed examinations provide a benefit to test performance in clinical anatomy. This study aimed to determine the impact of timed versus untimed practical tests on Master of Physical Therapy student anatomy performance and test anxiety. Test anxiety was measured using the State-Trait Anxiety Inventory (STAI). Differences in performance, anxiety scores, and time taken were compared using paired sample Student's t-tests. Eighty-one of the 84 students completed the study and provided feedback. Students performed significantly higher on the untimed test (P = 0.005), with a significant reduction in test anxiety (P < 0.001). Students who were unsuccessful on the timed test showed the greatest improvement on the untimed test ( x¯ = 20.4 ±10%). Eighty-three percent (n = 69) of students preferred the untimed test, 8.4% (n = 7) the timed test, and 8.4% (n = 7) had no preference. Students took on average eight minutes longer on the untimed test. This study found that physical therapy students perform better on untimed tests, which may be related to a reduction in test anxiety. If the intended goal of evaluating health care professional students is to determine fundamental competencies, these factors should be considered when designing future curricula. © 2014 American Association of Anatomists.

  8. Performance tests.

    PubMed Central

    Wetherell, A

    1996-01-01

    This paper discusses the use of psychological performance tests to assess the effects of environmental stressors. The large number and the variety of performance tests are illustrated, and the differences between performance tests and other psychological tests are described in terms of their design, construction, use, and purpose. The stressor emphasis is on the effects of drugs since that is where most performance tests have found their main application, although other stressors, e.g., fatigue, toxic chemicals, are mentioned where appropriate. Diazepam is used as an example. There is no particular performance emphasis since the tests are intended to have wide applicability. However, vehicle-driving performance is discussed because it has been the subject of a great deal of research and is probably one of the most important areas of application. Performance tests are discussed in terms of the four main underlying models--factor analysis, general information processing, multiple resource and strategy models, and processing-stage models--and in terms of their psychometric properties--sensitivity, reliability, and content, criterion, construct, and face validity. Some test taxonomies are presented. Standardization is also discussed with reference to the reaction time, mathematical processing, memory search, spatial processing, unstable tracking, verbal processing, and dual task tests used in the AGARD STRES battery. Some comments on measurement strengths and appropriate study designs and methods are included. PMID:9182033

  9. FUNCTIONAL PERFORMANCE TESTING OF THE HIP IN ATHLETES: A SYSTEMATIC REVIEW FOR RELIABILITY AND VALIDITY

    PubMed Central

    Martin, RobRoy L.

    2012-01-01

    Purpose/Background: The purpose of this study was to systematically review the literature for functional performance tests with evidence of reliability and validity that could be used for a young, athletic population with hip dysfunction. Methods: A search of PubMed and SPORTDiscus databases were performed to identify movement, balance, hop/jump, or agility functional performance tests from the current peer-reviewed literature used to assess function of the hip in young, athletic subjects. Results: The single-leg stance, deep squat, single-leg squat, and star excursion balance tests (SEBT) demonstrated evidence of validity and normative data for score interpretation. The single-leg stance test and SEBT have evidence of validity with association to hip abductor function. The deep squat test demonstrated evidence as a functional performance test for evaluating femoroacetabular impingement. Hop/Jump tests and agility tests have no reported evidence of reliability or validity in a population of subjects with hip pathology. Conclusions: Use of functional performance tests in the assessment of hip dysfunction has not been well established in the current literature. Diminished squat depth and provocation of pain during the single-leg balance test have been associated with patients diagnosed with FAI and gluteal tendinopathy, respectively. The SEBT and single-leg squat tests provided evidence of convergent validity through an analysis of kinematics and muscle function in normal subjects. Reliability of functional performance tests have not been established on patients with hip dysfunction. Further study is needed to establish reliability and validity of functional performance tests that can be used in a young, athletic population with hip dysfunction. Level of Evidence: 2b (Systematic Review of Literature) PMID:22893860

  10. Defining the Physiological Factors that Contribute to Postflight Changes in Functional Performance

    NASA Technical Reports Server (NTRS)

    Bloomberg, J. J.; Arzeno, N.; Buxton, R.; Feiveson, A. H.; Kofman, I.; Lawrence, E.; Lee, S. M. C.; Mulavara, A. P.; Peters, B. T.; Platts, S. H.; hide

    2009-01-01

    Astronauts experience alterations in multiple physiological systems due to exposure to the microgravity conditions of space flight. These physiological changes include sensorimotor disturbances, cardiovascular deconditioning and loss of muscle mass and strength. These changes might affect the ability of crewmembers to perform critical mission tasks immediately after landing on lunar and Martian surfaces. To date, changes in functional performance have not been systematically studied or correlated with physiological changes. To understand how changes in physiological function impact functional performance an interdisciplinary pre/postflight testing regimen (Functional Task Test, FTT) has been developed that systematically evaluates both astronaut postflight functional performance and related physiological changes. The overall objective of the FTT is to identify the key underlying physiological factors that contribute to performance of functional tests that are representative of critical mission tasks. This study will identify which physiological systems contribute the most to impaired performance on each functional test. This will allow us to identify the physiological systems that play the largest role in decrement in functional performance. Using this information we can then design and implement countermeasures that specifically target the physiological systems most responsible for the altered functional performance associated with space flight. The functional test battery was designed to address high priority tasks identified by the Constellation program as critical for mission success. The set of functional tests making up the FTT include the: 1) Seat Egress and Walk Test, 2) Ladder Climb Test, 3) Recovery from Fall/Stand Test, 4) Rock Translation Test, 5) Jump Down Test, 6) Torque Generation Test, and 7) Construction Activity Board Test. Corresponding physiological measures include assessments of postural and gait control, dynamic visual acuity, fine motor control, plasma volume, orthostatic intolerance, upper and lower body muscle strength, power, fatigue, control and neuromuscular drive. Crewmembers perform both functional and physiological tests before and after short (Shuttle) and long-duration (ISS) space flight. Data are collected on R+0 (Shuttle only), R+1, R+6 and R+30.

  11. Realistic Development and Testing of Fission System at a Non-Nuclear Testing Facility

    NASA Technical Reports Server (NTRS)

    Godfroy, Tom; VanDyke, Melissa; Dickens, Ricky; Pedersen, Kevin; Lenard, Roger; Houts, Mike

    2000-01-01

    The use of resistance heaters to simulate heat from fission allows extensive development of fission systems to be performed in non-nuclear test facilities, saving time and money. Resistance heated tests on a module has been performed at the Marshall Space Flight Center in the Propellant Energy Source Testbed (PEST). This paper discusses the experimental facilities and equipment used for performing resistance heated tests. Recommendations are made for improving non-nuclear test facilities and equipment for simulated testing of nuclear systems.

  12. Realistic development and testing of fission systems at a non-nuclear testing facility

    NASA Astrophysics Data System (ADS)

    Godfroy, Tom; van Dyke, Melissa; Dickens, Ricky; Pedersen, Kevin; Lenard, Roger; Houts, Mike

    2000-01-01

    The use of resistance heaters to simulate heat from fission allows extensive development of fission systems to be performed in non-nuclear test facilities, saving time and money. Resistance heated tests on a module has been performed at the Marshall Space Flight Center in the Propellant Energy Source Testbed (PEST). This paper discusses the experimental facilities and equipment used for performing resistance heated tests. Recommendations are made for improving non-nuclear test facilities and equipment for simulated testing of nuclear systems. .

  13. Design and Development of E3 Antenna Container,

    DTIC Science & Technology

    1985-09-03

    reinforced with square tubing. The walls and ceiling shall be insulated with expanded polystyrene . TEST LOCATION - This test will be performed at the...ceiling shall be insulated with expanded polystyrene . TEST LOCATION - This test will be performed at the Edgewater Machine & Fabricator’s facility...insulated with expanded polystyrene . TEST LOCATION - This test will be performed at the Edgewater Machine & Fabricator’s facility located at 200 N

  14. Effects of Seated Postural Stability and Trunk and Upper Extremity Strength on Performance during Manual Wheelchair Propulsion Tests in Individuals with Spinal Cord Injury: An Exploratory Study.

    PubMed

    Gagnon, Dany H; Roy, Audrey; Gabison, Sharon; Duclos, Cyril; Verrier, Molly C; Nadeau, Sylvie

    2016-01-01

    Objectives. To quantify the association between performance-based manual wheelchair propulsion tests (20 m propulsion test, slalom test, and 6 min propulsion test), trunk and upper extremity (U/E) strength, and seated reaching capability and to establish which ones of these variables best predict performance at these tests. Methods. 15 individuals with a spinal cord injury (SCI) performed the three wheelchair propulsion tests prior to discharge from inpatient SCI rehabilitation. Trunk and U/E strength and seated reaching capability with unilateral hand support were also measured. Bivariate correlation and multiple linear regression analyses allowed determining the best determinants and predictors, respectively. Results. The performance at the three tests was moderately or strongly correlated with anterior and lateral flexion trunk strength, anterior seated reaching distance, and the shoulder, elbow, and handgrip strength measures. Shoulder adductor strength-weakest side explained 53% of the variance on the 20-meter propulsion test-maximum velocity. Shoulder adductor strength-strongest side and forward seated reaching distance explained 71% of the variance on the slalom test. Handgrip strength explained 52% of the variance on the 6-minute propulsion test. Conclusion. Performance at the manual wheelchair propulsion tests is explained by a combination of factors that should be considered in rehabilitation.

  15. Crush Testing at Oak Ridge National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feldman, Matthew R

    2011-01-01

    The dynamic crush test is required in the certification testing of some small Type B transportation packages. International Atomic Energy Agency regulations state that the test article must be 'subjected to a dynamic crush test by positioning the specimen on the target so as to suffer maximum damage.' Oak Ridge National Laboratory (ORNL) Transportation Technologies Group performs testing of Type B transportation packages, including the crush test, at the National Transportation Research Center in Knoxville, Tennessee (United States). This paper documents ORNL's experiences performing crush tests on several different Type B packages. ORNL has crush tested five different drum-type packagemore » designs, continuing its 60 year history of RAM package testing. A total of 26 crush tests have been performed in a wide variety of package orientations and crush plate CG alignments. In all cases, the deformation of the outer drum created by the crush test was significantly greater than the deformation damage caused by the 9 m drop test. The crush test is a highly effective means for testing structural soundness of smaller nondense Type B shipping package designs. Further regulatory guidance could alleviate the need to perform the crush test in a wide range of orientations and crush plate CG alignments.« less

  16. 40 CFR 51.358 - Test equipment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 2 2014-07-01 2014-07-01 false Test equipment. 51.358 Section 51.358....358 Test equipment. Computerized emission test systems are required for performing an official emissions test on subject vehicles. (a) Performance features of computerized emission test systems. The...

  17. 40 CFR 51.358 - Test equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Test equipment. 51.358 Section 51.358....358 Test equipment. Computerized emission test systems are required for performing an official emissions test on subject vehicles. (a) Performance features of computerized emission test systems. The...

  18. Performing a Large-Scale Modal Test on the B2 Stand Crane at NASA's Stennis Space Center

    NASA Technical Reports Server (NTRS)

    Stasiunas, Eric C.; Parks, Russel A.

    2018-01-01

    A modal test of NASA’s Space Launch System (SLS) Core Stage is scheduled to occur prior to propulsion system verification testing at the Stennis Space Center B2 test stand. A derrick crane with a 180-ft long boom, located at the top of the stand, will be used to suspend the Core Stage in order to achieve defined boundary conditions. During this suspended modal test, it is expected that dynamic coupling will occur between the crane and the Core Stage. Therefore, a separate modal test was performed on the B2 crane itself, in order to evaluate the varying dynamic characteristics and correlate math models of the crane. Performing a modal test on such a massive structure was challenging and required creative test setup and procedures, including implementing both AC and DC accelerometers, and performing both classical hammer and operational modal analysis. This paper describes the logistics required to perform this large-scale test, as well as details of the test setup, the modal test methods used, and an overview of the results.

  19. Employment Standards for Australian Urban Firefighters: Part 4: Physical Aptitude Tests and Standards.

    PubMed

    Fullagar, Hugh H K; Sampson, John A; Mott, Brendan J; Burdon, Catriona A; Taylor, Nigel A S; Groeller, Herbert

    2015-10-01

    Firefighter physical aptitude tests were administered to unskilled subjects and operational firefighters to evaluate the impact that testing bias associated with gender, age, activity-specific skills, or task familiarity may have upon establishing performance thresholds. These tests were administered in sequence, simulating hazmat incidents, ventilation fan carriage (stairs), motor-vehicle rescues, bushfire incidents, fire attacks, and a firefighter rescue. Participants included two unskilled samples (N = 14 and 22) and 143 firefighters. Firefighter performance was not significantly different from the unskilled subjects. Participants from both genders passed the test, with scores unrelated to performance skill or age; however, familiarization significantly improved performance when the test was repeated. These outcomes confirmed this test to be gender-, age-, and skill-neutral. Familiarization effects could be removed through performing a single, pre-selection trial of the test battery.

  20. Measuring Several Aspects of Attention in One Test: The Factor Structure of Conners's Continuous Performance Test

    ERIC Educational Resources Information Center

    Egeland, Jens; Kovalik-Gran, Iwona

    2010-01-01

    Objective: Continuous performance tests are known to typically measure sustained attention but usually also yield parameters that potentially measure other subprocesses of attention. The aim of the present study was to test the factor structure of the Conners's Continuous Performance Test (CCPT) in a heterogeneous clinical sample consisting of…

  1. Comparing Postsecondary Marketing Student Performance on Computer-Based and Handwritten Essay Tests

    ERIC Educational Resources Information Center

    Truell, Allen D.; Alexander, Melody W.; Davis, Rodney E.

    2004-01-01

    The purpose of this study was to determine if there were differences in postsecondary marketing student performance on essay tests based on test format (i.e., computer-based or handwritten). Specifically, the variables of performance, test completion time, and gender were explored for differences based on essay test format. Results of the study…

  2. The Interaction between Cognitive Test-Taking Strategies, Reading Ability, and Reading Comprehension Test Performance of Iranian EFL Learners

    ERIC Educational Resources Information Center

    Ghafournia, Narjes; Afghari, Akbar

    2013-01-01

    The study scrutinized the probable interaction between using cognitive test-taking strategies, reading proficiency, and reading comprehension test performance of Iranian postgraduate students, who studied English as a foreign language. The study also probed the extent to which the participants' test performance was related to the use of certain…

  3. Computerized Adaptive Performance Evaluation.

    DTIC Science & Technology

    1980-02-01

    based on classical psychological test theory, with the result that the obtained measurements ani statements of achievement or performance have... psychological aspects of the achievement testing environment. Results , C Applications of Item Characteristic Curve Models and Adaptive Testing Strategies ICC...of immediate knowledge of results and adaptive testing on ability test performance (Research Report 76-4). Minneapolis: Department of Psychology

  4. Performance evaluation of the solar kinetics T-700 line concentrating solar collector

    NASA Technical Reports Server (NTRS)

    1981-01-01

    A performance evaluation of the solar kinetics T-700 line concentrating solar collector is reported. Collector descriptions, summary, test conditions, test equipment, test requirements and procedures, and an analysis of the various tests performed are described.

  5. 40 CFR 63.1161 - Performance testing and test methods.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Facilities and Hydrochloric Acid Regeneration Plants § 63.1161 Performance testing and test methods. (a...) or measure the concentration of HCl (and Cl2 for hydrochloric acid regeneration plants) in gases... to the initial test or tests. (c) Establishment of hydrochloric acid regeneration plant operating...

  6. 40 CFR 63.1161 - Performance testing and test methods.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Facilities and Hydrochloric Acid Regeneration Plants § 63.1161 Performance testing and test methods. (a...) or measure the concentration of HCl (and Cl2 for hydrochloric acid regeneration plants) in gases... to the initial test or tests. (c) Establishment of hydrochloric acid regeneration plant operating...

  7. 40 CFR 63.1161 - Performance testing and test methods.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Facilities and Hydrochloric Acid Regeneration Plants § 63.1161 Performance testing and test methods. (a...) or measure the concentration of HCl (and Cl2 for hydrochloric acid regeneration plants) in gases... to the initial test or tests. (c) Establishment of hydrochloric acid regeneration plant operating...

  8. End-of-test Performance and Wear Characterization of NASA's Evolutionary Xenon Thruster (NEXT) Long-Duration Test

    NASA Technical Reports Server (NTRS)

    Shastry, Rohit; Herman, Daniel Andrew; Soulas, George C.; Patterson, Michael J.

    2014-01-01

    This presentation describes results from the end-of-test performance characterization of NASA's Evolutionary Xenon Thruster (NEXT) Long-Duration Test (LDT). Sub-component performance as well as overall thruster performance is presented and compared to results over the course of the test. Overall wear of critical thruster components is also described, and an update on the first failure mode of the thruster is provided.

  9. Acoustic and Thermal Testing of an Integrated Multilayer Insulation and Broad Area Cooling Shield System

    NASA Technical Reports Server (NTRS)

    Wood, Jessica J.; Foster, Lee W.

    2013-01-01

    A Multilayer Insulation (MLI) and Broad Area Cooling (BAC) shield thermal control system shows promise for long-duration storage of cryogenic propellant. The NASA Cryogenic Propellant Storage and Transfer (CPST) project is investigating the thermal and structural performance of this tank-applied integrated system. The MLI/BAC Shield Acoustic and Thermal Test was performed to evaluate the MLI/BAC shield's structural performance by subjecting it to worst-case launch acoustic loads. Identical thermal tests using Liquid Nitrogen (LN2) were performed before and after the acoustic test. The data from these tests was compared to determine if any degradation occurred in the thermal performance of the system as a result of exposure to the acoustic loads. The thermal test series consisted of two primary components: a passive boil-off test to evaluate the MLI performance and an active cooling test to evaluate the integrated MLI/BAC shield system with chilled vapor circulating through the BAC shield tubes. The acoustic test used loads closely matching the worst-case envelope of all launch vehicles currently under consideration for CPST. Acoustic test results yielded reasonable responses for the given load. The thermal test matrix was completed prior to the acoustic test and successfully repeated after the acoustic test. Data was compared and yielded near identical results, indicating that the MLI/BAC shield configuration tested in this series is an option for structurally implementing this thermal control system concept.

  10. Stability, reliability and cross-mode correlations of tests in a recommended 8-minute performance assessment battery

    NASA Technical Reports Server (NTRS)

    Wilkes, R. L.; Kennedy, R. S.; Dunlap, W. P.; Lane, N. E.

    1986-01-01

    A need exists for an automated performance test system to study drugs, agents, treatments, and stresses of interest to the aviation, space, and environmental medical community. The purpose of this present study is to evaluate tests for inclusion in the NASA-sponsored Automated Performance Test System (APTS). Twenty-one subjects were tested over 10 replications with tests previously identified as good candidates for repeated-measure research. The tests were concurrently administered in paper-and-pencil and microcomputer modes. Performance scores for the two modes were compared. Data from trials 1 to 10 were examined for indications of test stability and reliability. Nine of the ten APT system tests achieved stability. Reliabilities were generally high. Cross-correlation of microbased tests with traditional paper-and-pencil versions revealed similarity of content within tests in the different modes, and implied at least three cognition and two motor factors. This protable, inexpensive, rugged, computerized battery of tests is recommended for use in repeated-measures studies of environmental and drug effects on performance. Identification of other tests compatible with microcomputer testing and potentially capable of tapping previously unidentified factors is recommended. Documentation of APTS sensitivity to environmental agents is available for more than a dozen facilities and is reported briefly. Continuation of such validation remains critical in establishing the efficacy of APTS tests.

  11. Validation of a short cognitive battery to screen for fitness-to-drive of people with multiple sclerosis.

    PubMed

    Akinwuntan, A E; Backus, D; Grayson, J; Devos, H

    2018-05-26

    Some symptoms of multiple sclerosis (MS) affect driving. In a recent study, performance on five cognitive tests predicted the on-road test performance of individuals with relapsing-remitting MS with 91% accuracy, 70% sensitivity and 97% specificity. However, the accuracy with which the battery will predict the driving performance of a different cohort that includes all types of MS is unknown. Participants (n = 118; 48 ± 9 years of age; 97 females) performed a comprehensive off-road evaluation that lasted about 3 h and a standardized on-road test that lasted approximately 45 min over a 2-day period within the same week. Performance on the five cognitive tests was used to predict participants' performance on the standardized on-road test. Performance on the five tests together predicted outcome of the on-road test with 82% accuracy, 42% sensitivity and 90% specificity. The accuracy of predicting the on-road performance of a new MS cohort using performance on the battery of five cognitive tests remained very high (82%). The battery, which was administrable in <45 min and cost ~$150, was better at identifying those who actually passed the on-road test (90% specificity). The sensitivity (42%) of the battery indicated that it should not be used as the sole determinant of poor driving-related cognitive skills. A fail performance on the battery should only imply that more comprehensive testing is warranted. © 2018 EAN.

  12. Keeping waived tests simple.

    PubMed

    2004-01-01

    Laboratories performing waived testing must follow the manufacturer's instructions as well as good laboratory practices to ensure that test results are reliable. Four things to concentrate on to maximize the performance and reliability of waived tests are to: 1. Read and follow the information found in the package inserts. 2. Follow the manufacturer's recommendations for running quality control. 3. Train staff members to perform tests correctly. 4. Follow established policies and procedures for patient testing in the practice.

  13. Task Identification and Evaluation System (TIES)

    DTIC Science & Technology

    1991-08-01

    Caliorate A N/AVh-11A- iUD -test -sets 127. Calibrate AN/AWII1-55 ASCU test setsI - 128. Calibrate 5001L11 tally punched tape readersI- 129. Perform...11AKHbD test sets -- 132. ?erform fault isolation of U4/AWN-55 ASCU -test sets -- 133. Perform fault isolation of 500 R.M tally punched tape I...AIN/AVM1-11A HfLM test sets- 137. Perf-orm self-tests of AL%/AWL-S5 ASCU test sets G. !MAI.T.T!ING A-7D_ ANUAL TEST SETS 138. Adjust SM-661/AS-388air

  14. 12 CFR 195.22 - Lending test.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 12 Banks and Banking 1 2012-01-01 2012-01-01 false Lending test. 195.22 Section 195.22 Banks and... Assessing Performance § 195.22 Lending test. (a) Scope of test. (1) The lending test evaluates a savings... lending test except the community development lending criterion. (b) Performance criteria. The appropriate...

  15. High-Stakes Accountability: Student Anxiety and Large-Scale Testing

    ERIC Educational Resources Information Center

    von der Embse, Nathaniel P.; Witmer, Sara E.

    2014-01-01

    This study examined the relationship between student anxiety about high-stakes testing and their subsequent test performance. The FRIEDBEN Test Anxiety Scale was administered to 1,134 11th-grade students, and data were subsequently collected on their statewide assessment performance. Test anxiety was a significant predictor of test performance…

  16. Thermal Performance Testing of EMU and CSAFE Liquid Cooling Garments

    NASA Technical Reports Server (NTRS)

    Rhodes, Richard; Bue, Grant; Hakam, Mark; Radford, Tamara

    2013-01-01

    Future exploration missions require the development of a new liquid cooling garment (LCG) that offers greater system reliability, is more comfortable, and maximizes thermal performance. To inform the development of a future LCG a thermal performance test was conducted to evaluate three factors: (1) the effect of the thermal comfort undergarment (TCU) on tactile and thermal comfort, (2) the comparable thermal performance of an CSAFE developed engineering evaluation unit (EEU) LCG, which uses a commercial-off-the-shelf (COTS) wicking garment as the base, and (3) the performance of a torso or upper body only LCG configuration to evaluate a proposed auxiliary loop configuration. To evaluate the thermal performance of each configuration a metabolic suit test was conducted, utilizing suited subjects to generate metabolic heat by walking on a treadmill at various speeds. Three (3) test subjects of similar height and weight produced a metabolic load for five tests by either resting (300-600 BTU/hr), walking at a slow pace (1200 BTU/hr), and walking at a brisk pace (2200 BTU/hr). During the test, data was collected that would allow us to track the heat transfer to the LCG and ventilation system to determine the thermal performance of the LCG configurations. Four different test configurations were tested, with one configuration tested twice. The test results show that the CSAFE EEU LCG and EMU LCG had comparable performance. The testing also showed that an auxiliary loop LCG, sized similarly to the shirt-only configuration, should provide adequate cooling for contingency scenarios. Finally, the testing showed the previous analysis that assumed a UA deterioration from the TCU was too conservative and the TCU may prove to be acceptable for future development with additional analysis and testing.

  17. Oxygen uptake during functional activities after stroke—Reliability and validity of a portable ergospirometry system

    PubMed Central

    Brurok, Berit; Tjønna, Arnt Erik; Tørhaug, Tom; Askim, Torunn

    2017-01-01

    Background People with stroke have a low peak aerobic capacity and experience increased effort during performance of daily activities. The purpose of this study was to examine test-retest reliability of a portable ergospirometry system in people with stroke during performance of functional activities in a field-test. Secondary aims were to examine the proportion of oxygen consumed during the field-test in relation to the peak-test and to analyse the correlation between the oxygen uptake during the field-test and peak-test in order to support the validity of the field-test. Methods With simultaneous measurement of oxygen consumption, participants performed a standardized field-test consisting of five activities; walking over ground, stair walking, stepping over obstacles, walking slalom between cones and from a standing position lifting objects from one height to another. All activities were performed in self-selected speed. Prior to the field-test, a peak aerobic capacity test was performed. The field-test was repeated minimum 2 and maximum 14 days between the tests. ICC2,1 and Bland Altman tests (Limits of Agreement, LoA) were used to analyse test-retest reliability. Results In total 31 participants (39% women, mean (SD) age 54.5 (12.7) years and 21.1 (14.3) months’ post-stroke) were included. The ICC2,1 was ≥ 0.80 for absolute V̇O2, relative V̇O2, minute ventilation, CO2, respiratory exchange ratio, heart rate and Borgs rating of perceived exertion. ICC2,1 for total time to complete the field-test was 0.99. Mean difference in steady state V̇O2 during Test 1 and Test 2 was -0.40 (2.12) The LoAs were -3.75 and 4.51. Participants spent 60.7% of their V̇O2peak performing functional activities. Correlation between field-test and peak-test was 0.689, p = 0.001 for absolute and 0.733, p = 0.001 for relative V̇O2. Conclusions This study presents first evidence on reliability of oxygen uptake during performance of functional activities after stroke, showing very good test-retest reliability. The secondary analysis showed that the amount of energy spent during the field-test relative to the peak-test was high and the correlation between the two test was good, supporting the validity of this method. PMID:29065164

  18. Repeat six-minute walk tests in patients with chronic heart failure: are they clinically necessary?

    PubMed

    Adsett, Julie; Mullins, Robert; Hwang, Rita; Hogden, Amy; Gibson, Ellen; Houlihan, Kylie; Tuppin, Michael; Korczyk, Dariusz; Mallitt, Kylie-Ann; Mudge, Alison

    2011-08-01

    Owing to a reported learning effect in patients with chronic cardiopulmonary disease, performance of at least two six-minute walk tests (6MWT) are recommended as standard practice. Patients with chronic heart failure (CHF) are typically elderly and frail and it is unknown whether current guidelines are practical in a clinical setting. The aim of this study was to determine whether repeat performance of 6MWTs in patients with CHF is related to between-test interval or baseline performance. This was a multisite observational study enrolling participants entering into heart failure rehabilitation programmes. Participants performed two 6MWTs with randomly allocated inter-test intervals between 15 and 90 minutes. Distance walked in the second test was compared with the first test using a paired t test. Eighty-eight participants (45 females, age 65 ± 14 years) with stable CHF were enrolled. Mean distance walked increased from 301 metres in test 1 to 313 metres in test 2 (p < 0.001). No significant change was recorded between test 1 and test 2 for those whose baseline distance was <300 metres. The interval between tests had no significant effect on the distance walked. The change in 6MWT distance was significantly associated with better baseline performance but not with the interval between tests.

  19. Reliability and validity of two isometric squat tests.

    PubMed

    Blazevich, Anthony J; Gill, Nicholas; Newton, Robert U

    2002-05-01

    The purpose of the present study was first to examine the reliability of isometric squat (IS) and isometric forward hack squat (IFHS) tests to determine if repeated measures on the same subjects yielded reliable results. The second purpose was to examine the relation between isometric and dynamic measures of strength to assess validity. Fourteen male subjects performed maximal IS and IFHS tests on 2 occasions and 1 repetition maximum (1-RM) free-weight squat and forward hack squat (FHS) tests on 1 occasion. The 2 tests were found to be highly reliable (intraclass correlation coefficient [ICC](IS) = 0.97 and ICC(IFHS) = 1.00). There was a strong relation between average IS and 1-RM squat performance, and between IFHS and 1-RM FHS performance (r(squat) = 0.77, r(FHS) = 0.76; p < 0.01), but a weak relation between squat and FHS test performances (r < 0.55). There was also no difference between observed 1-RM values and those predicted by our regression equations. Errors in predicting 1-RM performance were in the order of 8.5% (standard error of the estimate [SEE] = 13.8 kg) and 7.3% (SEE = 19.4 kg) for IS and IFHS respectively. Correlations between isometric and 1-RM tests were not of sufficient size to indicate high validity of the isometric tests. Together the results suggest that IS and IFHS tests could detect small differences in multijoint isometric strength between subjects, or performance changes over time, and that the scores in the isometric tests are well related to 1-RM performance. However, there was a small error when predicting 1-RM performance from isometric performance, and these tests have not been shown to discriminate between small changes in dynamic strength. The weak relation between squat and FHS test performance can be attributed to differences in the movement patterns of the tests

  20. Papanicolaou Testing by Physicians in Manitoba: Who Does Them?

    PubMed Central

    Cohen, Marsha M.; Hammarstrand, Karen M.

    1989-01-01

    Pap testing is one of the few effective preventive health practices available to primary care physicians. Yet we know little about how well this procedure is being done. Using data from the province of Manitoba's universal health insurance plan for the years 1976, 1978 and 1982, we determined the proportion of all Pap tests of women over 25 years of age performed by the various physician specialties; the percentage of physicians in each specialty who performed tests; and the mean number of tests per specialty group. We also determined the mean number of tests by age and training of the physician. The number of physicians performing Pap tests increased from 749 in 1976 to 780 in 1982. About 2% of Pap tests performed in the province were done by internists, 5% by general surgeons, about 33% by obstetrician/gynecologists, 40% by urban general practitioners, and 22% by rural general practitioners. Other physicians accounted for less than 0.2% of all tests. The mean number of Pap tests performed increased with increasing physician age up to age 60 and declined thereafter. Manitoba-trained physicians performed the highest rate of Pap testing, and this pattern was maintained over time. In 1982, only 22% of internists, 29% of general surgeons, and 78% of family physicians/general practitioners were performing tests. These results raise the question of why a significant number of physicians are not carrying out this effective preventive health practice. PMID:21248879

  1. Computer versus paper--does it make any difference in test performance?

    PubMed

    Karay, Yassin; Schauber, Stefan K; Stosch, Christoph; Schüttpelz-Brauns, Katrin

    2015-01-01

    CONSTRUCT: In this study, we examine the differences in test performance between the paper-based and the computer-based version of the Berlin formative Progress Test. In this context it is the first study that allows controlling for students' prior performance. Computer-based tests make possible a more efficient examination procedure for test administration and review. Although university staff will benefit largely from computer-based tests, the question arises if computer-based tests influence students' test performance. A total of 266 German students from the 9th and 10th semester of medicine (comparable with the 4th-year North American medical school schedule) participated in the study (paper = 132, computer = 134). The allocation of the test format was conducted as a randomized matched-pair design in which students were first sorted according to their prior test results. The organizational procedure, the examination conditions, the room, and seating arrangements, as well as the order of questions and answers, were identical in both groups. The sociodemographic variables and pretest scores of both groups were comparable. The test results from the paper and computer versions did not differ. The groups remained within the allotted time, but students using the computer version (particularly the high performers) needed significantly less time to complete the test. In addition, we found significant differences in guessing behavior. Low performers using the computer version guess significantly more than low-performing students in the paper-pencil version. Participants in computer-based tests are not at a disadvantage in terms of their test results. The computer-based test required less processing time. The reason for the longer processing time when using the paper-pencil version might be due to the time needed to write the answer down, controlling for transferring the answer correctly. It is still not known why students using the computer version (particularly low-performing students) guess at a higher rate. Further studies are necessary to understand this finding.

  2. 40 CFR 600.207-08 - Calculation and use of vehicle-specific 5-cycle-based fuel economy values for vehicle...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... (i) Calculate the 5-cycle city and highway fuel economy values from the tests performed using gasoline or diesel test fuel. (ii)(A) Calculate the 5-cycle city and highway fuel economy values from the tests performed using alcohol or natural gas test fuel, if 5-cycle testing has been performed. Otherwise...

  3. Largo hot water system long range thermal performance test report, addendum

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The test procedure used and the test results obtained during the long range thermal performance tests of the LARGO Solar Hot Water System under natural environmental conditions are presented. Objectives of these tests were to determine the amount of energy collected, the amount of power required for system operation, system efficiency, temperature distribution, and system performance degradation.

  4. Associations between physical function, dual-task performance and cognition in patients with mild Alzheimer's disease.

    PubMed

    Sobol, Nanna Aue; Hoffmann, Kristine; Vogel, Asmus; Lolk, Annette; Gottrup, Hanne; Høgh, Peter; Hasselbalch, Steen G; Beyer, Nina

    2016-11-01

    Alzheimer's disease (AD) causes a gradual decline in cognition, limitations of dual-tasking and physical function leading to total dependence. Hence, information about the interaction between physical function, dual-task performance and cognition may lead to new treatment strategies with the purpose of preserving function and quality of life. The objective of this study was to investigate the associations between physical function, dual-task performance and cognition in community-dwelling patients with mild AD. Baseline results from 185 participants (50-90 years old) in the single blinded multicenter RCT 'ADEX' (Alzheimer's disease: the effect of physical exercise) were used. Assessments included tests of physical function: 400-m walk test, 10-m walk test, Timed Up and Go test and 30-s chair stand test; dual-task performance, i.e., 10-m walk while counting backwards from 50 or naming the months backwards; and cognition, i.e., Mini Mental State Examination, Symbol Digit Modalities Test, the Stroop Color and Word Test, and Lexical verbal fluency test. Results in the 30-s chair stand test correlated significantly with all tests of cognition (r = .208-.242) while the other physical function tests only randomly correlated with tests of cognition. Results in the dual-task counting backwards correlated significantly with results in all tests of cognition (r = .259-.388), which accounted for 7%-15% of the variation indicating that a faster time to complete dual-task performance was associated with better cognitive performance. The evidence of the associations between physical function, dual-task performance and cognition is important when creating new rehabilitation interventions to patients with mild AD.

  5. Evaluation of Asphalt Mixture Low-Temperature Performance in Bending Beam Creep Test.

    PubMed

    Pszczola, Marek; Jaczewski, Mariusz; Rys, Dawid; Jaskula, Piotr; Szydlowski, Cezary

    2018-01-10

    Low-temperature cracking is one of the most common road pavement distress types in Poland. While bitumen performance can be evaluated in detail using bending beam rheometer (BBR) or dynamic shear rheometer (DSR) tests, none of the normalized test methods gives a comprehensive representation of low-temperature performance of the asphalt mixtures. This article presents the Bending Beam Creep test performed at temperatures from -20 °C to +10 °C in order to evaluate the low-temperature performance of asphalt mixtures. Both validation of the method and its utilization for the assessment of eight types of wearing courses commonly used in Poland were described. The performed test indicated that the source of bitumen and its production process (and not necessarily only bitumen penetration) had a significant impact on the low-temperature performance of the asphalt mixtures, comparable to the impact of binder modification (neat, polymer-modified, highly modified) and the aggregate skeleton used in the mixture (Stone Mastic Asphalt (SMA) vs. Asphalt Concrete (AC)). Obtained Bending Beam Creep test results were compared with the BBR bitumen test. Regression analysis confirmed that performing solely bitumen tests is insufficient for comprehensive low-temperature performance analysis.

  6. Evaluation of Asphalt Mixture Low-Temperature Performance in Bending Beam Creep Test

    PubMed Central

    Rys, Dawid; Jaskula, Piotr; Szydlowski, Cezary

    2018-01-01

    Low-temperature cracking is one of the most common road pavement distress types in Poland. While bitumen performance can be evaluated in detail using bending beam rheometer (BBR) or dynamic shear rheometer (DSR) tests, none of the normalized test methods gives a comprehensive representation of low-temperature performance of the asphalt mixtures. This article presents the Bending Beam Creep test performed at temperatures from −20 °C to +10 °C in order to evaluate the low-temperature performance of asphalt mixtures. Both validation of the method and its utilization for the assessment of eight types of wearing courses commonly used in Poland were described. The performed test indicated that the source of bitumen and its production process (and not necessarily only bitumen penetration) had a significant impact on the low-temperature performance of the asphalt mixtures, comparable to the impact of binder modification (neat, polymer-modified, highly modified) and the aggregate skeleton used in the mixture (Stone Mastic Asphalt (SMA) vs. Asphalt Concrete (AC)). Obtained Bending Beam Creep test results were compared with the BBR bitumen test. Regression analysis confirmed that performing solely bitumen tests is insufficient for comprehensive low-temperature performance analysis. PMID:29320443

  7. Z-1 Prototype Space Suit Testing Summary

    NASA Technical Reports Server (NTRS)

    Ross, Amy

    2013-01-01

    The Advanced Space Suit team of the NASA-Johnson Space Center performed a series of test with the Z-1 prototype space suit in 2012. This paper discusses, at a summary level, the tests performed and results from those tests. The purpose of the tests were two-fold: 1) characterize the suit performance so that the data could be used in the downselection of components for the Z-2 Space Suit and 2) develop interfaces with the suitport and exploration vehicles through pressurized suit evaluations. Tests performed included isolated and functional range of motion data capture, Z-1 waist and hip testing, joint torque testing, CO2 washout testing, fit checks and subject familiarizations, an exploration vehicle aft deck and suitport controls interface evaluation, delta pressure suitport tests including pressurized suit don and doff, and gross mobility and suitport ingress and egress demonstrations in reduced gravity. Lessons learned specific to the Z-1 prototype and to suit testing techniques will be presented.

  8. Z-1 Prototype Space Suit Testing Summary

    NASA Technical Reports Server (NTRS)

    Ross, Amy J.

    2012-01-01

    The Advanced Space Suit team of the NASA-Johnson Space Center performed a series of test with the Z-1 prototype space suit in 2012. This paper discusses, at a summary level, the tests performed and results from those tests. The purpose of the tests were two -fold: 1) characterize the suit performance so that the data could be used in the downselection of components for the Z -2 Space Suit and 2) develop interfaces with the suitport and exploration vehicles through pressurized suit evaluations. Tests performed included isolated and functional range of motion data capture, Z-1 waist and hip testing, joint torque testing, CO2 washout testing, fit checks and subject familiarizations, an exploration vehicle aft deck and suitport controls interface evaluation, delta pressure suitport tests including pressurized suit don and doff, and gross mobility and suitport ingress and egress demonstrations in reduced gravity. Lessons learned specific to the Z -1 prototype and to suit testing techniques will be presented.

  9. CAN UPPER EXTREMITY FUNCTIONAL TESTS PREDICT THE SOFTBALL THROW FOR DISTANCE: A PREDICTIVE VALIDITY INVESTIGATION

    PubMed Central

    Hanney, William J.; Kolber, Morey J.; Davies, George J.; Riemann, Bryan

    2011-01-01

    Introduction: Understanding the relationships between performance tests and sport activity is important to the rehabilitation specialist. The purpose of this study was two- fold: 1) To identify if relationships exist between tests of upper body strength and power (Single Arm Seated Shot Put, Timed Push-Up, Timed Modified Pull-Up, and The Davies Closed Kinetic Chain Upper Extremity Stability Test, and the softball throw for distance), 2) To determine which variable or group of variables best predicts the performance of a sport specific task (the softball throw for distance). Methods: One hundred eighty subjects (111 females and 69 males, aged 18-45 years) performed the 5 upper extremity tests. The Pearson product moment correlation and a stepwise regression were used to determine whether relationships existed between performance on the tests and which upper extremity test result best explained the performance on the softball throw for distance. Results: There were significant correlations (r=.33 to r=.70, p=0.001) between performance on all of the tests. The modified pull-up test was the best predictor of the performance on the softball throw for distance (r2= 48.7), explaining 48.7% of variation in performance. When weight, height, and age were added to the regression equation the r2 values increased to 64.5, 66.2, and 67.5 respectively. Conclusion: The results of this study indicate that several upper extremity tests demonstrate significant relationships with one another and with the softball throw for distance. The modified pull up test was the best predictor of performance on the softball throw for distance. PMID:21712942

  10. Correlations between Physical Fitness Tests and Performance of Military Tasks: A Systematic Review and Meta-Analyses

    DTIC Science & Technology

    2014-06-30

    U.S. Army Public Health Command Correlations between Physical Fitness Tests and Performance of Military Tasks: A Systematic Review and Meta...30 JUN 2014 2. REPORT TYPE Final 3. DATES COVERE D 4. TITLE AN D SUBTITLE Correlations between Physical Fitness Tests and Performance of... Physical Fitness Test (APFT) and ensure a future test is associated with Soldiers’ performance of common physical job requirements, the USAPHC applied

  11. CF6 jet engine performance improvement program. Short core exhaust nozzle performance improvement concept. [specific fuel consumption reduction

    NASA Technical Reports Server (NTRS)

    Fasching, W. A.

    1979-01-01

    The short core exhaust nozzle was evaluated in CF6-50 engine ground tests including performance, acoustic, and endurance tests. The test results verified the performance predictions from scale model tests. The short core exhaust nozzle provides an internal cruise sfc reduction of 0.9 percent without an increase in engine noise. The nozzle hardware successfully completed 1000 flight cycles of endurance testing without any signs of distress.

  12. Performance Validity Testing in Neuropsychology: Scientific Basis and Clinical Application-A Brief Review.

    PubMed

    Greher, Michael R; Wodushek, Thomas R

    2017-03-01

    Performance validity testing refers to neuropsychologists' methodology for determining whether neuropsychological test performances completed in the course of an evaluation are valid (ie, the results of true neurocognitive function) or invalid (ie, overly impacted by the patient's effort/engagement in testing). This determination relies upon the use of either standalone tests designed for this sole purpose, or specific scores/indicators embedded within traditional neuropsychological measures that have demonstrated this utility. In response to a greater appreciation for the critical role that performance validity issues play in neuropsychological testing and the need to measure this variable to the best of our ability, the scientific base for performance validity testing has expanded greatly over the last 20 to 30 years. As such, the majority of current day neuropsychologists in the United States use a variety of measures for the purpose of performance validity testing as part of everyday forensic and clinical practice and address this issue directly in their evaluations. The following is the first article of a 2-part series that will address the evolution of performance validity testing in the field of neuropsychology, both in terms of the science as well as the clinical application of this measurement technique. The second article of this series will review performance validity tests in terms of methods for development of these measures, and maximizing of diagnostic accuracy.

  13. Effects of Electric Vehicle Fast Charging on Battery Life and Vehicle Performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matthew Shirk; Jeffrey Wishart

    2015-04-01

    As part of the U.S. Department of Energy’s Advanced Vehicle Testing Activity, four new 2012 Nissan Leaf battery electric vehicles were instrumented with data loggers and operated over a fixed on-road test cycle. Each vehicle was operated over the test route, and charged twice daily. Two vehicles were charged exclusively by AC level 2 EVSE, while two were exclusively DC fast charged with a 50 kW charger. The vehicles were performance tested on a closed test track when new, and after accumulation of 50,000 miles. The traction battery packs were removed and laboratory tested when the vehicles were new, andmore » at 10,000-mile intervals. Battery tests include constant-current discharge capacity, electric vehicle pulse power characterization test, and low peak power tests. The on-road testing was carried out through 70,000 miles, at which point the final battery tests were performed. The data collected over 70,000 miles of driving, charging, and rest are analyzed, including the resulting thermal conditions and power and cycle demands placed upon the battery. Battery performance metrics including capacity, internal resistance, and power capability obtained from laboratory testing throughout the test program are analyzed. Results are compared within and between the two groups of vehicles. Specifically, the impacts on battery performance, as measured by laboratory testing, are explored as they relate to battery usage and variations in conditions encountered, with a primary focus on effects due to the differences between AC level 2 and DC fast charging. The contrast between battery performance degradation and the effect on vehicle performance is also explored.« less

  14. 40 CFR 63.7515 - When must I conduct subsequent performance tests or fuel analyses?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... performance tests or fuel analyses? 63.7515 Section 63.7515 Protection of Environment ENVIRONMENTAL PROTECTION... Requirements § 63.7515 When must I conduct subsequent performance tests or fuel analyses? (a) You must conduct... previous performance test. (f) You must conduct a fuel analysis according to § 63.7521 for each type of...

  15. 40 CFR 63.11220 - When must I conduct subsequent performance tests or fuel analyses?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... performance tests or fuel analyses? 63.11220 Section 63.11220 Protection of Environment ENVIRONMENTAL... When must I conduct subsequent performance tests or fuel analyses? (a) If your boiler has a heat input... performance (stack) tests according to § 63.11212 on a triennial basis, except as specified in paragraphs (b...

  16. 40 CFR 63.7515 - When must I conduct subsequent performance tests, fuel analyses, or tune-ups?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... performance tests, fuel analyses, or tune-ups? 63.7515 Section 63.7515 Protection of Environment ENVIRONMENTAL... Compliance Requirements § 63.7515 When must I conduct subsequent performance tests, fuel analyses, or tune... and the associated initial fuel analyses within 90 days after the completion of the performance tests...

  17. 40 CFR 63.7515 - When must I conduct subsequent performance tests or fuel analyses?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... performance tests or fuel analyses? 63.7515 Section 63.7515 Protection of Environment ENVIRONMENTAL PROTECTION... Requirements § 63.7515 When must I conduct subsequent performance tests or fuel analyses? (a) You must conduct... previous performance test. (f) You must conduct a fuel analysis according to § 63.7521 for each type of...

  18. 40 CFR 63.11220 - When must I conduct subsequent performance tests or fuel analyses?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... performance tests or fuel analyses? 63.11220 Section 63.11220 Protection of Environment ENVIRONMENTAL... When must I conduct subsequent performance tests or fuel analyses? (a) If your boiler has a heat input... performance (stack) tests according to § 63.11212 on a triennial basis, except as specified in paragraphs (b...

  19. 40 CFR 63.7515 - When must I conduct subsequent performance tests, fuel analyses, or tune-ups?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... performance tests, fuel analyses, or tune-ups? 63.7515 Section 63.7515 Protection of Environment ENVIRONMENTAL... Compliance Requirements § 63.7515 When must I conduct subsequent performance tests, fuel analyses, or tune... and the associated initial fuel analyses within 90 days after the completion of the performance tests...

  20. 40 CFR 63.7515 - When must I conduct subsequent performance tests or fuel analyses?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... performance tests or fuel analyses? 63.7515 Section 63.7515 Protection of Environment ENVIRONMENTAL PROTECTION... Requirements § 63.7515 When must I conduct subsequent performance tests or fuel analyses? (a) You must conduct... previous performance test. (f) You must conduct a fuel analysis according to § 63.7521 for each type of...

  1. 40 CFR 63.7187 - What performance tests and other compliance procedures must I use?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 13 2010-07-01 2010-07-01 false What performance tests and other... Manufacturing Compliance Requirements § 63.7187 What performance tests and other compliance procedures must I use? (a) You must conduct each performance test in Table 1 to this subpart that applies to you as...

  2. 40 CFR 63.1512 - Performance test/compliance demonstration requirements and procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... operator must conduct a performance test to measure THC and D/F emissions at the outlet of the control.../decoating kiln. The owner or operator must conduct performance tests to measure emissions of THC, D/F, HCl... operating temperature of each afterburner every 15 minutes during the THC and D/F performance tests; (ii...

  3. 40 CFR 63.1512 - Performance test/compliance demonstration requirements and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... operator must conduct a performance test to measure THC and D/F emissions at the outlet of the control.../decoating kiln. The owner or operator must conduct performance tests to measure emissions of THC, D/F, HCl... operating temperature of each afterburner every 15 minutes during the THC and D/F performance tests; (ii...

  4. 40 CFR 63.3960 - By what date must I conduct performance tests and other initial compliance demonstrations?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... performance test of one representative magnet wire coating machine for each group of identical or very similar... you complete the performance test of a representative magnet wire coating machine. The requirements in... operations, you may, with approval, conduct a performance test of a single magnet wire coating machine that...

  5. Cryogenic Thermal Performance Testing of Bulk-Fill and Aerogel Insulation Materials

    NASA Technical Reports Server (NTRS)

    Scholtens, B. E.; Fesmire, J. E.; Sass, J. P.; Augustynowicz, S. D.; Heckle, K. W.

    2007-01-01

    The research testing and demonstration of new bulk-fill materials for cryogenic thermal insulation systems was performed by the Cryogenics Test Laboratory at NASA Kennedy Space Center. Thermal conductivity testing under actual-use cryogenic conditions is a key to understanding the total system performance encompassing engineering, economics, and materials factors. A number of bulk fill insulation materials, including aerogel beads, glass bubbles, and perlite powder, were tested using a new cylindrical cryostat. Boundary temperatures for the liquid nitrogen boil-off method were 293 K and 78 K. Tests were performed as a function of cold vacuum pressure from high vacuum to no vacuum conditions. Results are compared with other complementary test methods in the range of 300 K to 20 K. Various testing techniques are shown to be required to obtain a complete understanding of the operating performance of a material and to provide data for answers to design engineering questions.

  6. Affordable Electro-Magnetic Interference (EMI) Testing on Large Space Vehicles

    NASA Technical Reports Server (NTRS)

    Aldridge, Edward; Curry, Bruce; Scully, Robert

    2015-01-01

    Objective: Perform System-Level EMI testing of the Orion Exploration Flight Test-1 (EFT-1) spacecraft in situ in the Kennedy Space Center's Neil Armstrong Operations & Checkout (O&C) Facility in 6 days. The only way to execute the system-level EMI testing and meet this schedule challenge was to perform the EMI testing in situ in the Final Assembly & System Test (FAST) Cell in a reverberant mode, not the direct illumination mode originally planned. This required the unplanned construction of a Faraday Cage around the vehicle and FAST Cell structure. The presence of massive steel platforms created many challenges to developing an efficient screen room to contain the RF energy and yield an effective reverberant chamber. An initial effectiveness test showed marginal performance, but improvements implemented afterward resulted in the final test performing surprisingly well! The paper will explain the design, the challenges, and the changes that made the difference in performance!

  7. The Influence of Body Mass on Physical Fitness Test Performance in Male Firefighter Applicants.

    PubMed

    Phillips, Devin B; Scarlett, Michael P; Petersen, Stewart R

    2017-11-01

    The influence of body mass on test performance was investigated in 414 male firefighter applicants who completed a maximal treadmill test and five task-simulation tests while dressed in fire protective ensemble. Subjects were assigned to six mass categories from less than 70 kg to more than 110 kg, in 10 kg increments (n = 69 in each). Treadmill performance was lower (P < 0.05) in the two heaviest groups. Charged hose advance time was slower in the two lightest groups. The lightest group had slower times for weighted sled pull, forcible entry, and victim rescue tests. The heaviest group was slower on the ladder climb test. Lighter subjects had a small advantage in endurance-oriented tests while higher mass appeared to improve performance slightly in strength-oriented tests. However, mass explained only 4% to 19% of the variance in performance.

  8. Butyl rubber O-ring seals: Revision of test procedures for stockpile materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Domeier, L.A.; Wagter, K.R.

    1996-12-01

    Extensive testing showed little correlation between test slab and O-ring performance. New procedures, comparable to those used with the traditional test slabs, were defined for hardness, compression set, and tensile property testing on sacrificial O-ring specimens. Changes in target performance values were made as needed and were, in one case, tightened to reflect the O-ring performance data. An additional study was carried out on O-ring and slab performance vs cure cycle and showed little sensitivity of material performance to large changes in curing time. Aging and spectra of certain materials indicated that two sets of test slabs from current vendormore » were accidently made from EPDM rather than butyl rubber. Random testing found no O-rings made from EPDM. As a result, and additional spectroscope test will be added to the product acceptance procedures to verify the type of rubber compound used.« less

  9. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Performance Verification Report: Initial Comprehensive Performance Test Report, P/N 1331200-2-IT, S/N 105/A2

    NASA Technical Reports Server (NTRS)

    Platt, R.

    1999-01-01

    This is the Performance Verification Report, Initial Comprehensive Performance Test Report, P/N 1331200-2-IT, S/N 105/A2, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A). The specification establishes the requirements for the Comprehensive Performance Test (CPT) and Limited Performance Test (LPT) of the Advanced Microwave Sounding, Unit-A2 (AMSU-A2), referred to herein as the unit. The unit is defined on Drawing 1331200. 1.2 Test procedure sequence. The sequence in which the several phases of this test procedure shall take place is shown in Figure 1, but the sequence can be in any order.

  10. 40 CFR 63.5992 - When must I conduct subsequent performance tests?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... performance tests? 63.5992 Section 63.5992 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... CATEGORIES National Emissions Standards for Hazardous Air Pollutants: Rubber Tire Manufacturing General Testing and Initial Compliance Requirements § 63.5992 When must I conduct subsequent performance tests? If...

  11. Validity, Reliability, and Performance Determinants of a New Job-Specific Anaerobic Work Capacity Test for the Norwegian Navy Special Operations Command.

    PubMed

    Angeltveit, Andreas; Paulsen, Gøran; Solberg, Paul A; Raastad, Truls

    2016-02-01

    Operators in Special Operation Forces (SOF) have a particularly demanding profession where physical and psychological capacities can be challenged to the extremes. The diversity of physical capacities needed depend on the mission. Consequently, tests used to monitor SOF operators' physical fitness should cover a broad range of physical capacities. Whereas tests for strength and aerobic endurance are established, there is no test for specific anaerobic work capacity described in the literature. The purpose of this study was therefore to evaluate the reliability, validity, and to identify performance determinants of a new test developed for testing specific anaerobic work capacity in SOF operators. Nineteen active young students were included in the concurrent validity part of the study. The students performed the evacuation (EVAC) test 3 times and the results were compared for reliability and with performance in the Wingate cycle test, 300-m sprint, and a maximal accumulated oxygen deficit (MAOD) test. In part II of the study, 21 Norwegian Navy Special Operations Command operators conducted the EVAC test, anthropometric measurements, a dual x-ray absorptiometry scan, leg press, isokinetic knee extensions, maximal oxygen uptake test, and countermovement jump (CMJ) test. The EVAC test showed good reliability after 1 familiarization trial (intraclass correlation = 0.89; coefficient of variance = 3.7%). The EVAC test correlated well with the Wingate test (r = -0.68), 300-m sprint time (r = 0.51), and 300-m mean power (W) (r = -0.67). No significant correlation was found with the MAOD test. In part II of the study, height, body mass, lean body mass, isokinetic knee extension torque, maximal oxygen uptake, and maximal power in a CMJ was significantly correlated with performance in the EVAC test. The EVAC test is a reliable and valid test for anaerobic work capacity for SOF operators, and muscle mass, leg strength, and leg power seem to be the most important determinants of performance.

  12. A review of cryogenic testing performed by the thermochemical test branch, Manned Spacecraft Center in support of Apollo 13 and14

    NASA Technical Reports Server (NTRS)

    Propp, C. E.; Mcgee, J. M.

    1971-01-01

    The Apollo 13 anomaly provided considerable impetus for a variety of types of cryogenic and ignition tests. The logic of the various test program designs, the test techniques, and their final impact upon the investigation findings are described. In addition, several test programs initiated to determine the thermal performance and general performance characteristics of the redesigned Apollo 14 cryogenic storage system are presented.

  13. Effects of Seated Postural Stability and Trunk and Upper Extremity Strength on Performance during Manual Wheelchair Propulsion Tests in Individuals with Spinal Cord Injury: An Exploratory Study

    PubMed Central

    Roy, Audrey; Gabison, Sharon; Verrier, Molly C.

    2016-01-01

    Objectives. To quantify the association between performance-based manual wheelchair propulsion tests (20 m propulsion test, slalom test, and 6 min propulsion test), trunk and upper extremity (U/E) strength, and seated reaching capability and to establish which ones of these variables best predict performance at these tests. Methods. 15 individuals with a spinal cord injury (SCI) performed the three wheelchair propulsion tests prior to discharge from inpatient SCI rehabilitation. Trunk and U/E strength and seated reaching capability with unilateral hand support were also measured. Bivariate correlation and multiple linear regression analyses allowed determining the best determinants and predictors, respectively. Results. The performance at the three tests was moderately or strongly correlated with anterior and lateral flexion trunk strength, anterior seated reaching distance, and the shoulder, elbow, and handgrip strength measures. Shoulder adductor strength-weakest side explained 53% of the variance on the 20-meter propulsion test-maximum velocity. Shoulder adductor strength-strongest side and forward seated reaching distance explained 71% of the variance on the slalom test. Handgrip strength explained 52% of the variance on the 6-minute propulsion test. Conclusion. Performance at the manual wheelchair propulsion tests is explained by a combination of factors that should be considered in rehabilitation. PMID:27635262

  14. Validity of cervical auscultation in the screening for aspiration.

    PubMed

    Al Hawat, A; Woisard, V; Perez-Begout, L; Sarrabère, E; Grand, S; Puech, M

    2014-01-01

    Cervical auscultation could improve the performance of bedside swallowing test to predict aspiration, especially silent aspiration. The aim of this study is to compare the predictive values of bedside swallowing test performed with and without cervical auscultation by logopedist students who had intensive training on cervical auscultation. 64 patients were included in the study. They all underwent swallowing test alone, combined swallowing test and cervical auscultation, and videofluoroscopic swallowing study as defined gold standard. Two logopedist students, at the end of their training, performed the auscultation and noted their results. 128 tests were performed, 96% of the tests were judged positive for aspiration. When comparing the results of the two different clinical tests, the detection of clinical signs is not improved by the addition of auscultation. Using a penetration aspiration scale threshold >5, the area under the curve measured for the swallowing test alone was significantly higher than that measured for the combined tests (p = 0.03) (0.66 for the swallowing test alone (95% CI between 0.49 and 0.83), and 0.50 for the combined tests (95% CI between 0.31 and 0.69). This study showed no advantage in performing cervical auscultation with bedside swallowing test. Cervical auscultation seems to hamper the assessment, mainly the perception of wet voice and laryngeal motion. These results are compatible with literature but need further confirmation using studies performed with trained logopedists.

  15. Thermal performance of MSFC hot air collectors under natural and simulated conditions

    NASA Technical Reports Server (NTRS)

    Shih, K., Sr.

    1977-01-01

    The procedures used and the results obtained from an evaluation test program conducted to determine the thermal performance and structural characteristics of selected MSFC--designed hot air collectors under both real and simulated environmental conditions are described. Five collectors were tested in the three phased program. A series of outdoor tests were conducted to determine stagnation temperatures on a typical bright day and to determine each collector's ability to withstand these temperatures. Two of the collectors experienced structural deformation sufficient to eliminate them from the remainder of the test program. A series of outdoor tests to evaluate the thermal performance of collector S/N 10 under certain test conditions were performed followed by a series of indoor tests to evaluate the thermal performance of the collector under closely controlled simulated conditions.

  16. Evaluation of a new computerized psychometric test battery: Effects of zolpidem and caffeine.

    PubMed

    Pilli, Raveendranadh; Naidu, Mur; Pingali, Usharani; Shobha, Jc

    2013-10-01

    To evaluate the effects of centrally active drugs using a new indigenously developed automated psychometric test system and compare the results with that obtained using pencil- and paper-based techniques. The tests were standardized in 24 healthy participants. Reproducibility of the test procedure was evaluated by performing the tests by a single experimenter on two occasions (interday reproducibility). To evaluate the sensitivity of the tests, the effects of zolpidem (5 mg) and caffeine (500 mg) versus placebo were studied in 24 healthy participants in a randomized, double-blind three-way crossover design. Psychometric tests were performed at baseline and at 1, 2, and 3 h after administration of study medication. The effects of zolpidem and caffeine on the psychomotor performance were most pronounced 1 h after administration. At this time, a significant impairment of performance in the simple reaction test (SRT), choice discrimination test (CDT), digit symbol substitution test (DSST), digit vigilance test (DVT), and card sorting test (CST) was observed with zolpidem. In contrast, caffeine showed a significant improvement in performance in CDT and DVT only. The results suggest that the tests of the computerized system are more sensitive and reliable then the pencil and paper tests in detecting the effects of central acting agents and are suitable for use in clinical areas to conduct studies with patients.

  17. Are the General Medical Council's Tests of Competence fair to long standing doctors? A retrospective cohort study.

    PubMed

    Mehdizadeh, Leila; Sturrock, Alison; Dacre, Jane

    2015-04-21

    The General Medical Council's Fitness to Practise investigations may involve a test of competence for doctors with performance concerns. Concern has been raised about the suitability of the test format for doctors who qualified before the introduction of Single Best Answer and Objective Structured Clinical Examination assessments, both of which form the test of competence. This study explored whether the examination formats used in the tests of competence are fair to long standing doctors who have undergone fitness to practise investigation. A retrospective cohort design was used to determine an association between year of primary medical qualification and doctors' test of competence performance. Performance of 95 general practitioners under investigation was compared with a group of 376 volunteer doctors. We analysed performance on knowledge test, OSCE overall, and three individual OSCE stations using Spearman's correlation and regression models. Doctors under investigation performed worse on all test outcomes compared to the comparison group. Qualification year correlated positively with performance on all outcomes except for physical examination (e.g. knowledge test r = 0.48, p < 0.001 and OSCE r = 0.37, p < 0.001). Qualification year was associated with test performance in doctors under investigation even when controlling for sex, ethnicity and qualification region. Regression analyses showed that qualification year was associated with knowledge test, OSCE and communication skills performance of doctors under investigation when other variables were controlled for. Among volunteer doctors this was not the case and their performance was more strongly related to where they qualified and their ethnic background. Furthermore, volunteer doctors who qualified before the introduction of Single Best Answer and OSCE assessments, still outperformed their peers under investigation. Earlier graduates under fitness to practise investigation performed less well on the test of competence than their more recently qualified peers under investigation. The performance of the comparator group tended to stay consistent irrespective of year qualified. Our results suggest that the test format does not disadvantage early qualified doctors. We discuss findings in relation to the GMC's fitness to practise procedures and suggest alternative explanations for the poorer performance of long standing doctors under investigation.

  18. Association between physiological falls risk and physical performance tests among community-dwelling older adults.

    PubMed

    Singh, Devinder K A; Pillai, Sharmila G K; Tan, Sin Thien; Tai, Chu Chiau; Shahar, Suzana

    2015-01-01

    Physical performance and balance declines with aging and may lead to increased risk of falls. Physical performance tests may be useful for initial fall-risk screening test among community-dwelling older adults. Physiological profile assessment (PPA), a composite falls risk assessment tool is reported to have 75% accuracy to screen for physiological falls risk. PPA correlates with Timed Up and Go (TUG) test. However, the association between many other commonly used physical performance tests and PPA is not known. The aim of the present study was to examine the association between physiological falls risk measured using PPA and a battery of physical performance tests. One hundred and forty older adults from a senior citizens club in Kuala Lumpur, Malaysia (94 females, 46 males), aged 60 years and above (65.77±4.61), participated in this cross-sectional study. Participants were screened for falls risk using PPA. A battery of physical performance tests that include ten-step test (TST), short physical performance battery (SPPB), functional reach test (FRT), static balance test (SBT), TUG, dominant hand-grip strength (DHGS), and gait speed test (GST) were also performed. Spearman's rank correlation and binomial logistic regression were performed to examine the significantly associated independent variables (physical performance tests) with falls risk (dependent variable). Approximately 13% older adults were at high risk of falls categorized using PPA. Significant differences (P<0.05) were demonstrated for age, TST, SPPB, FRT, SBT, TUG between high and low falls risk group. A significant (P<0.01) weak correlation was found between PPA and TST (r=0.25), TUG (r=0.27), SBT (r=0.23), SPPB (r=-0.33), and FRT (r=-0.23). Binary logistic regression results demonstrated that SBT measuring postural sways objectively using a balance board was the only significant predictor of physiological falls risk (P<0.05, odds ratio of 2.12). The reference values of physical performance tests in our study may be used as a guide for initial falls screening to categorize high and low physiological falls risk among community-dwelling older adults. A more comprehensive assessment of falls risk can be performed thereafter for more specific intervention of underlying impairments.

  19. Performing a Large-Scale Modal Test on the B2 Stand Crane at NASA's Stennis Space Center

    NASA Technical Reports Server (NTRS)

    Stasiunas, Eric C.; Parks, Russel A.; Sontag, Brendan D.

    2018-01-01

    A modal test of NASA's Space Launch System (SLS) Core Stage is scheduled to occur at the Stennis Space Center B2 test stand. A derrick crane with a 150-ft long boom, located at the top of the stand, will be used to suspend the Core Stage in order to achieve defined boundary conditions. During this suspended modal test, it is expected that dynamic coupling will occur between the crane and the Core Stage. Therefore, a separate modal test was performed on the B2 crane itself, in order to evaluate the varying dynamic characteristics and correlate math models of the crane. Performing a modal test on such a massive structure was challenging and required creative test setup and procedures, including implementing both AC and DC accelerometers, and performing both classical hammer and operational modal analysis. This paper describes the logistics required to perform this large-scale test, as well as details of the test setup, the modal test methods used, and an overview and application of the results.

  20. Test of acoustic tone source and propulsion performance of C8A Buffalo suppressor nozzle

    NASA Technical Reports Server (NTRS)

    Marrs, C. C.; Harkonen, D. L.; Okeefe, J. V.

    1974-01-01

    Results are presented for a static acoustic and propulsion performance ground test conducted at the Boeing hot nozzle facility on the C8A Buffalo noise suppressor nozzle. Various methods to remove a nozzle-associated 2000-Hz tone are evaluated. Results of testing this rectangular-array lobed nozzle for propulsion performance and acoustic directivity are reported. Recommendations for future nozzle modifications and further testing are included. Appendix A contains the test plan. Appendix B presents the test log. Appendix C contains plots of the one-third octave sound pressure levels recorded during the test. Appendix D describes the acoustic data recording and reduction systems. The performance data is tabulated in Appendix E.

  1. Embedded performance validity testing in neuropsychological assessment: Potential clinical tools.

    PubMed

    Rickards, Tyler A; Cranston, Christopher C; Touradji, Pegah; Bechtold, Kathleen T

    2018-01-01

    The article aims to suggest clinically-useful tools in neuropsychological assessment for efficient use of embedded measures of performance validity. To accomplish this, we integrated available validity-related and statistical research from the literature, consensus statements, and survey-based data from practicing neuropsychologists. We provide recommendations for use of 1) Cutoffs for embedded performance validity tests including Reliable Digit Span, California Verbal Learning Test (Second Edition) Forced Choice Recognition, Rey-Osterrieth Complex Figure Test Combination Score, Wisconsin Card Sorting Test Failure to Maintain Set, and the Finger Tapping Test; 2) Selecting number of performance validity measures to administer in an assessment; and 3) Hypothetical clinical decision-making models for use of performance validity testing in a neuropsychological assessment collectively considering behavior, patient reporting, and data indicating invalid or noncredible performance. Performance validity testing helps inform the clinician about an individual's general approach to tasks: response to failure, task engagement and persistence, compliance with task demands. Data-driven clinical suggestions provide a resource to clinicians and to instigate conversation within the field to make more uniform, testable decisions to further the discussion, and guide future research in this area.

  2. Repeated sprint ability related to recovery time in young soccer players.

    PubMed

    Padulo, J; Tabben, M; Ardigò, L P; Ionel, M; Popa, C; Gevat, C; Zagatto, A M; Dello Iacono, A

    2015-01-01

    This study aimed to describe the influence of recovery duration during a repeated sprint ability (RSA) test (6 × 40 m) by investigating a number of variables, such as general performance, metabolic demand, and muscular stretch-shortening performance. Seventeen male soccer outfield players (16 ± 0 years, 66 ± 10 kg) performed three field shuttle-running tests with 15, 20, and 25-sec recoveries. In addition to specific shuttle test's variables, blood lactate concentration and vertical jump height were assessed. Resulting measures were highly reliable (intra-class correlation coefficient up to 0.86). 25-sec recovery improved test performance (-3% total time from 15-sec to 25-sec recovery), vertical jump height (+7% post-test height from 15-sec to 25-sec recovery), and decreased blood lactate accumulation (-33% post-test from 15-sec to 25-sec recovery). Study findings suggest that metabolic acidosis plays a role in worsening performance and fatigue development during the shuttle test. A 25-sec recovery duration maximized performance, containing metabolic-anaerobic power involvement and muscular stretch-shortening performance deterioration during a RSA test.

  3. The validity of ACT-PEP test scores for predicting academic performance of registered nurses in BSN programs.

    PubMed

    Yang, J C; Noble, J

    1990-01-01

    This study investigated the validity of three American College Testing-Proficiency Examination Program (ACT-PEP) tests (Maternal and Child Nursing, Psychiatric/Mental Health Nursing, Adult Nursing) for predicting the academic performance of registered nurses (RNs) enrolled in bachelor's degree BSN programs nationwide. This study also examined RN students' performance on the ACT-PEP tests by their demographic characteristics: student's age, sex, race, student status (full- or part-time), and employment status (full- or part-time). The total sample for the three tests comprised 2,600 students from eight institutions nationwide. The median correlation coefficients between the three ACT-PEP tests and the semester grade point averages ranged from .36 to .56. Median correlation coefficients increased over time, supporting the stability of ACT-PEP test scores for predicting academic performance over time. The relative importance of selected independent variables for predicting academic performance was also examined; the most important variable for predicting academic performance was typically the ACT-PEP test score. Across the institutions, student demographic characteristics did not contribute significantly to explaining academic performance, over and above ACT-PEP scores.

  4. EFFECT OF ATHLETIC TAPING AND KINESIOTAPING® ON MEASUREMENTS OF FUNCTIONAL PERFORMANCE IN BASKETBALL PLAYERS WITH CHRONIC INVERSION ANKLE SPRAINS

    PubMed Central

    Karatas, Nihan; Baltaci, Gul

    2012-01-01

    Background: Chronic inversion ankle sprains are common in basketball players. The effect of taping on functional performance is disputed in the literature. Kinesiotaping® (KT®) is a new method that is being used as both a therapeutic and performance enhancement tool. To date, it appears that no study has investigated the effect of ankle KT® on functional performance. Purpose: To investigate the effects of different types of taping (KT® using Kinesio Tex®, athletic taping) on functional performance in athletes with chronic inversion sprains of the ankle. Study Design: Crossover Study Design Methods: Fifteen male basketball players with chronic inversion ankle sprains between the ages of 18 and 22 participated in this study. Functional performance tests (Hopping test by Amanda et al, Single Limb Hurdle Test, Standing Heel Rise test, Vertical Jump Test, The Star Excursion Balance Test [SEBT] and Kinesthetic Ability Trainer [KAT] Test) were used to quantify agility, endurance, balance, and coordination. These tests were conducted four times at one week intervals using varied conditions: placebo tape, without tape, standard athletic tape, and KT®. One-way ANOVA tests were used to examine difference in measurements between conditions. Bonferroni correction was applied to correct for repeated testing. Results: There were no significant differences among the results obtained using the four conditions for SEBT (anterior p=0.0699; anteromedial p=0.126; medial p=0.550; posteromedial p=0.587; posterior p=0.754; posterolateral p=0.907; lateral p=0.124; anterolateral p=0.963) and the KAT dynamic measurement (p=0.388). Faster performance times were measured with KT® and athletic tape in single limb hurdle test when compared to placebo and non-taped conditions (Athletic taping- placebo taping: p=0.03; athletic taping- non tape p=0.016;KT®- Placebo taping p=0.042; KT®-Non tape p=0.016). In standing heel rise test and vertical jump test, athletic taping led to decreased performance. (Standing heel rise test: Athletic taping- placebo taping p=0.035; athletic taping- non tape p=0.043; athletic tape- KT® p<0.001) (Vertical jump test: Athletic taping- placebo taping p=0.002: athletic taping- non tape p=0.002; KT®- athletic tape p<0.001) Conclusion: Kinesiotaping® had no negative effects on a battery of functional performance tests and improvements were seen in some functional performance tests. Clinical Relevance: Ankle taping using Kinesio Tex® Tape did not inhibit functional performance. PMID:22530190

  5. Effect of athletic taping and kinesiotaping® on measurements of functional performance in basketball players with chronic inversion ankle sprains.

    PubMed

    Bicici, Seda; Karatas, Nihan; Baltaci, Gul

    2012-04-01

    Chronic inversion ankle sprains are common in basketball players. The effect of taping on functional performance is disputed in the literature. Kinesiotaping® (KT®) is a new method that is being used as both a therapeutic and performance enhancement tool. To date, it appears that no study has investigated the effect of ankle KT® on functional performance. To investigate the effects of different types of taping (KT® using Kinesio Tex®, athletic taping) on functional performance in athletes with chronic inversion sprains of the ankle. Crossover Study Design Fifteen male basketball players with chronic inversion ankle sprains between the ages of 18 and 22 participated in this study. Functional performance tests (Hopping test by Amanda et al, Single Limb Hurdle Test, Standing Heel Rise test, Vertical Jump Test, The Star Excursion Balance Test [SEBT] and Kinesthetic Ability Trainer [KAT] Test) were used to quantify agility, endurance, balance, and coordination. These tests were conducted four times at one week intervals using varied conditions: placebo tape, without tape, standard athletic tape, and KT®. One-way ANOVA tests were used to examine difference in measurements between conditions. Bonferroni correction was applied to correct for repeated testing. There were no significant differences among the results obtained using the four conditions for SEBT (anterior p=0.0699; anteromedial p=0.126; medial p=0.550; posteromedial p=0.587; posterior p=0.754; posterolateral p=0.907; lateral p=0.124; anterolateral p=0.963) and the KAT dynamic measurement (p=0.388). Faster performance times were measured with KT® and athletic tape in single limb hurdle test when compared to placebo and non-taped conditions (Athletic taping- placebo taping: p=0.03; athletic taping- non tape p=0.016;KT®- Placebo taping p=0.042; KT®-Non tape p=0.016). In standing heel rise test and vertical jump test, athletic taping led to decreased performance. (Standing heel rise test: Athletic taping- placebo taping p=0.035; athletic taping- non tape p=0.043; athletic tape- KT® p<0.001) (Vertical jump test: Athletic taping- placebo taping p=0.002: athletic taping- non tape p=0.002; KT®- athletic tape p<0.001) Kinesiotaping® had no negative effects on a battery of functional performance tests and improvements were seen in some functional performance tests. Ankle taping using Kinesio Tex® Tape did not inhibit functional performance.

  6. Predictors of invalid neuropsychological test performance after traumatic brain injury.

    PubMed

    Moore, Bret A; Donders, Jacobus

    2004-10-01

    To investigate the usefulness of the Test of Memory Malingering (TOMM) and the California Verbal Learning Test-Second Edition (CVLT-II) in assessing invalid test performance after traumatic brain injury (TBI). Consecutive 3-year series of rehabilitation referrals (n = 132). Percentage of participants who failed validity criteria was determined. Hierarchical logistic regression analysis and odds ratios were used to identify predictors of invalid test performance. Twenty patients (15%) performed in the invalid range when held to a priori specified criteria for invalid test performance (i.e. TOMM <45/50 on Trial 2 or CVLT-II <15/16 on Forced-Choice recognition trial). Both psychiatric history and financial compensation seeking were associated with an almost 4-fold increase in likelihood of invalid responding. The TOMM and CVLT-II are sensitive to the potential impact of current financial compensation seeking and prior psychiatric history on neuropsychological test performance after TBI.

  7. Development of a test protocol for evaluating EVA glove performance

    NASA Technical Reports Server (NTRS)

    Hinman, Elaine M.

    1992-01-01

    Testing gloved hand performance involves work from several disciplines. Evaluations performed in the course of reenabling a disabled hand, designing a robotic end effector or master controller, or hard-suit design have all yielded relevant information, and, in most cases, produced performance test methods. Most times, these test methods have been primarily oriented toward their parent discipline. For space operations, a comparative test which would provide a way to quantify pressure glove and end effector performance would be useful in dividing tasks between humans and robots. Such a test would have to rely heavily on sensored measurement, as opposed to questionnaires, to produce relevant data. However, at some point human preference would have to be taken into account. This paper presents a methodology for evaluating gloved hand performance which attempts to respond to these issues. Glove testing of a prototype glove design using this method is described.

  8. 33 CFR 183.584 - Shock test.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Tests § 183.584 Shock test. A fuel tank is tested by performing the following procedures in the following order: (a) Perform the static pressure test under § 183... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Shock test. 183.584 Section 183...

  9. 33 CFR 183.584 - Shock test.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Tests § 183.584 Shock test. A fuel tank is tested by performing the following procedures in the following order: (a) Perform the static pressure test under § 183... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Shock test. 183.584 Section 183...

  10. 33 CFR 183.584 - Shock test.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Tests § 183.584 Shock test. A fuel tank is tested by performing the following procedures in the following order: (a) Perform the static pressure test under § 183... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Shock test. 183.584 Section 183...

  11. 33 CFR 183.588 - Slosh test.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Tests § 183.588 Slosh test. A fuel tank is tested by performing the following procedures in the following order: (a) Perform the static pressure test under § 183... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Slosh test. 183.588 Section 183...

  12. 33 CFR 183.588 - Slosh test.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Tests § 183.588 Slosh test. A fuel tank is tested by performing the following procedures in the following order: (a) Perform the static pressure test under § 183... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Slosh test. 183.588 Section 183...

  13. 33 CFR 183.584 - Shock test.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Tests § 183.584 Shock test. A fuel tank is tested by performing the following procedures in the following order: (a) Perform the static pressure test under § 183... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Shock test. 183.584 Section 183...

  14. 33 CFR 183.588 - Slosh test.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Tests § 183.588 Slosh test. A fuel tank is tested by performing the following procedures in the following order: (a) Perform the static pressure test under § 183... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Slosh test. 183.588 Section 183...

  15. 33 CFR 183.588 - Slosh test.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Tests § 183.588 Slosh test. A fuel tank is tested by performing the following procedures in the following order: (a) Perform the static pressure test under § 183... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Slosh test. 183.588 Section 183...

  16. 33 CFR 183.588 - Slosh test.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Slosh test. 183.588 Section 183... SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Tests § 183.588 Slosh test. A fuel tank is tested by performing the following procedures in the following order: (a) Perform the static pressure test under § 183...

  17. 33 CFR 183.584 - Shock test.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Shock test. 183.584 Section 183... SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Tests § 183.584 Shock test. A fuel tank is tested by performing the following procedures in the following order: (a) Perform the static pressure test under § 183...

  18. Topical Knowledge in L2 Speaking Assessment: Comparing Independent and Integrated Speaking Test Tasks

    ERIC Educational Resources Information Center

    Huang, Heng-Tsung Danny; Hung, Shao-Ting Alan; Plakans, Lia

    2018-01-01

    Integrated speaking test tasks (integrated tasks) provide reading and/or listening input to serve as the basis for test-takers to formulate their oral responses. This study examined the influence of topical knowledge on integrated speaking test performance and compared independent speaking test performance and integrated speaking test performance…

  19. Testing of small and large sign support systems FOIL test number : 92F011

    DOT National Transportation Integrated Search

    1994-07-01

    This test report contains the results of a crash test performed at the Federal Outdoor Impact Laboratory (FOIL) in McLean, Virginia. The test was performed on a small sign support system at 20 mi/h (8.9 m/s), test 92FOll. The vehicle used for these t...

  20. Testing of small and large sign support systems FOIL test number : 92F036

    DOT National Transportation Integrated Search

    1994-07-01

    This test report contains the results of a crash test performed at the Federal Outdoor Impact Laboratory (FOIL) in McLean, Virginia. The test was performed on a small sign support system at 60 mi/h (96.6 km/h), test 92F036. The vehicle used for this ...

  1. Testing of small and large sign support systems FOIL test number : 92F016

    DOT National Transportation Integrated Search

    1994-07-01

    This test report contains the results of a crash test performed at the Federal Outdoor : Impact Laboratory (FOIL) in McLean, Virginia. The test was performed on a small sign : support system at 20 mi/h (8.9 m/s), test 92F016. The vehicle used for the...

  2. Testing of small and large sign support systems FOIL test number : 92F035

    DOT National Transportation Integrated Search

    1994-07-01

    This test report contains the results of a crash test performed at the Federal Outdoor Impact Laboratory (FOIL) in McLean, Virginia. The test was performed on a small sign support system at 20 mi/h (32.2 km/h), test 92F035. The vehicle used for this ...

  3. Testing of small and large sign support systems FOIL test number : 92F038

    DOT National Transportation Integrated Search

    1994-01-01

    This test report contains the results of a crash test performed at the Federal Outdoor Impact Laboratory (FOIL) in McLean, Virginia. The test was performed on a small sign support system at 60 mi/h (96.6 km/h), test 92F038. The vehicle used for this ...

  4. Testing of small and large sign support systems FOIL test number : 92F037

    DOT National Transportation Integrated Search

    1994-07-01

    This test report contains the results of a crash test performed at the Federal Outdoor Impact Laboratory (FOIL) in McLean, Virginia. The test was performed on a small sign support system at 20 mi/h (32.2 km/h), test 92F037. The vehicle used for this ...

  5. Testing of small and large sign support systems FOIL test number : 92F022

    DOT National Transportation Integrated Search

    1994-07-01

    This test report contains the results of a crash test performed at the Federal Outdoor Impact laboratory (FOIL) in Mclean, Virginia. The test was performed on a small sign support system at 20 mi/h (8.9 m/s) , test 92F022. The vehicle used for this t...

  6. Testing of small and large sign support systems FOIL test numbers : 92F040

    DOT National Transportation Integrated Search

    1994-07-01

    This test report contains the results of a crash test performed at the Federal Outdoor Impact Laboratory (FOIL) in McLean, Virginia. The test was performed on a small sign support system at 60 mi/h (96.6 km/h), test 92F040. The vehicle used for this ...

  7. Testing of small and large sign support systems FOIL test number : 92F039

    DOT National Transportation Integrated Search

    1994-07-01

    This test report contains the results of a crash test performed at the Federal Outdoor Impact Laboratory (FOIL) in McLean, Virginia. The test was performed on a small sign support system at 20 mi/h (32.2 km/h) , test 92F039. The vehicle used for this...

  8. Physical Performance in Elite Male and Female Team Handball Players.

    PubMed

    Wagner, Herbert; Fuchs, Patrick; Fusco, Andrea; Fuchs, Philip; Bell, W Jeffrey; Duvillard, Serge P

    2018-06-12

    Biological differences between men and women are well known; however, literature-addressing knowledge about the influence of sex to specific and general performance in team handball is almost nonexistent. Consequently, the aim of the study was to assess and compare specific and general physical performance in male and female elite team handball players, to determine if the differences are consequential for general compared to specific physical performance characteristics and the relationship between general and specific physical performance. Twelve male and ten female elite team handball players performed a game based performance test, upper- und lower-body strength and power tests, a sprinting test, and an incremental treadmill-running test. Significant differences (P<.05) between male and female players were found for peak oxygen uptake and total running time during the treadmill test, 30m sprinting time, leg extension strength, trunk and shoulder rotation torque, counter movement jump height as well as offense and defense time, ball velocity and jump height in the game based performance test. An interaction (sex × test) was found for time and oxygen uptake and except shoulder rotation torque and ball velocity in females, we found only a low relationship between specific and general physical performance. The results of the study revealed that male players are heavier, taller, faster, stronger, jump higher and have a better aerobic performance. However, female players performed relatively better in the team handball specific tests compared to the general tests. Our findings also suggest that female players should focus more on strength training.

  9. Differential effects of scopolamine and amphetamine on microcomputer-based performance tests

    NASA Technical Reports Server (NTRS)

    Kennedy, Robert S.; Odenheimer, Robert C.; Baltzley, Dennis R.; Dunlap, William P.; Wood, Charles D.

    1990-01-01

    The effects of four weekly treatments with scopolamine (1.0 mg) and d-amphetamine (10 mg), separately or in combination, on human performance were investigated in 16 subjects undergoing nine performance tests from a menu of microcomputer-based tests administered after the treatment. It was d-amphetamine treatment that enhanced the results of motor and perceptual speed tests, while scopolamine had no effect on these tests. Two of the five cognitive tests showed reductions with scopolamine. The effects of scopolamine in this and other studies are considered in terms of a model which implies that the magnitude of the performance deficit depends on the performance type and the dosage level of the drug.

  10. The DOE ETV-1 Electric Test Vehicle. Phase 3: Performance Testing and system evaluation

    NASA Technical Reports Server (NTRS)

    Kurtz, D.

    1981-01-01

    Engineering tests were conducted in order to characterize overall system performance and component efficiencies within the system environment. A dynamometer was used in order to minimize the ambient effects and large uncertainties present in track testing. Extensive test requirements were defined and procedures were carefully controlled in order to maintain a high degree of credibility. Limited track testing was performed in order to corroborate the dynamometer results. Test results include an energy flow analysis through the major subsystems and incorporate the aerodynamic and rolling losses under cyclic and various steady speed conditions. The major output from all relevant dynamometer and track tests is also included.

  11. Neuropsychological test scores, academic performance, and developmental disorders in Spanish-speaking children.

    PubMed

    Rosselli, M; Ardila, A; Bateman, J R; Guzmán, M

    2001-01-01

    Limited information is currently available about performance of Spanish-speaking children on different neuropsychological tests. This study was designed to (a) analyze the effects of age and sex on different neuropsychological test scores of a randomly selected sample of Spanish-speaking children, (b) analyze the value of neuropsychological test scores for predicting school performance, and (c) describe the neuropsychological profile of Spanish-speaking children with learning disabilities (LD). Two hundred ninety (141 boys, 149 girls) 6- to 11-year-old children were selected from a school in Bogotá, Colombia. Three age groups were distinguished: 6- to 7-, 8- to 9-, and 10- to 11-year-olds. Performance was measured utilizing the following neuropsychological tests: Seashore Rhythm Test, Finger Tapping Test (FTT), Grooved Pegboard Test, Children's Category Test (CCT), California Verbal Learning Test-Children's Version (CVLT-C), Benton Visual Retention Test (BVRT), and Bateria Woodcock Psicoeducativa en Español (Woodcock, 1982). Normative scores were calculated. Age effect was significant for most of the test scores. A significant sex effect was observed for 3 test scores. Intercorrelations were performed between neuropsychological test scores and academic areas (science, mathematics, Spanish, social studies, and music). In a post hoc analysis, children presenting very low scores on the reading, writing, and arithmetic achievement scales of the Woodcock battery were identified in the sample, and their neuropsychological test scores were compared with a matched normal group. Finally, a comparison was made between Colombian and American norms.

  12. Blast Performance of Commercially Available Demining Footwear: A Summary of Experimental Trials on Surrogate Legs

    DTIC Science & Technology

    2008-10-01

    Equipment Department of the Dutch Ministry of Defence tasked TNO Defence, Security and Safety to perform AP mine shoe tests to study the protection level...would not provide more insight. Therefore only two tests at 75 g were performed . The test results are summarized in Table 2. The high speed video...be able to better place foot into shoe . But still damage of gelatine prior to test. Pretest x-ray performed to show damage prior to test. The

  13. Do Performance-Based Wheelchair Propulsion Tests Detect Changes Among Manual Wheelchair Users With Spinal Cord Injury During Inpatient Rehabilitation in Quebec?

    PubMed

    Gagnon, Dany H; Roy, Audrey; Verrier, Molly C; Duclos, Cyril; Craven, B Cathy; Nadeau, Sylvie

    2016-07-01

    To quantify and compare the responsiveness and concurrent validity of 3 performance-based manual wheelchair propulsion tests among manual wheelchair users with subacute spinal cord injury (SCI) undergoing inpatient rehabilitation. Quasi-experimental repeated-measures design. Publicly funded comprehensive inpatient SCI rehabilitation program. Consenting adult manual wheelchair users with a subacute SCI admitted and discharged from inpatient rehabilitation (N=14). Participants performed 20-m propulsion at both self-selected natural and maximal speeds, the slalom, and the 6-minute propulsion tests at rehabilitation admission and discharge. Time required to complete the performance-based wheelchair propulsion tests. Standardized response means (SRMs) were computed for each performance test and Pearson correlation coefficients (r) were calculated to explore the associations between performance tests. The slalom (SRM=1.24), 20-m propulsion at maximum speed (SRM=.99), and 6-minute propulsion tests (SRM=.84) were the most responsive. The slalom and 20-m propulsion at maximum speed were strongly correlated at both admission (r=.93) and discharge (r=.92). The slalom and 6-minute propulsion tests best document wheelchair propulsion performance change over the course of inpatient rehabilitation. Adding the 20-m propulsion test performed at maximal speed provides a complementary description of performance change. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  14. Hot-Fire Testing of a 1N AF-M315E Thruster

    NASA Technical Reports Server (NTRS)

    Burnside, Christopher G.; Pedersen, Kevin; Pierce, Charles W.

    2015-01-01

    This hot-fire test continues NASA investigation of green propellant technologies for future missions. To show the potential for green propellants to replace some hydrazine systems in future spacecraft, NASA Marshall Space Flight Center (MSFC) is continuing to embark on hot-fire test campaigns with various green propellant blends. NASA completed a hot-fire test of a 1N AF-M315E monopropellant thruster at the Marshall Space Flight Center in the small altitude test stand located in building 4205. The thruster is a ground test article used for basic performance determination and catalyst studies. The purpose of the hot-fire testing was for performance determination of a 1N size thruster and form a baseline from which to study catalyst performance and life with follow-on testing to be conducted at a later date. The thruster performed as expected. The result of the hot-fire testing are presented in this paper and presentation.

  15. Test Vehicle Forebody Wake Effects on CPAS Parachutes

    NASA Technical Reports Server (NTRS)

    Ray, Eric S.

    2017-01-01

    Parachute drag performance has been reconstructed for a large number of Capsule Parachute Assembly System (CPAS) flight tests. This allows for determining forebody wake effects indirectly through statistical means. When data are available in a "clean" wake, such as behind a slender test vehicle, the relative degradation in performance for other test vehicles can be computed as a Pressure Recovery Fraction (PRF). All four CPAS parachute types were evaluated: Forward Bay Cover Parachutes (FBCPs), Drogues, Pilots, and Mains. Many tests used the missile-shaped Parachute Compartment Drop Test Vehicle (PCDTV) to obtain data at high airspeeds. Other tests used the Orion "boilerplate" Parachute Test Vehicle (PTV) to evaluate parachute performance in a representative heatshield wake. Drag data from both vehicles are normalized to a "capsule" forebody equivalent for Orion simulations. A separate database of PCDTV-specific performance is maintained to accurately predict flight tests. Data are shared among analogous parachutes whenever possible to maximize statistical significance.

  16. Predicting the clinical performance of dental students with a manual dexterity test

    PubMed Central

    Lugassy, Diva; Levanon, Yafi; Pilo, Raphael; Shelly, Asaf; Rosen, Gal; Meirowitz, Avi

    2018-01-01

    Dentists must be skilled when using dental mirrors. Working with mirrors requires spatial perception, bimanual coordination, perceptual learning and fine motor skills. Many studies have attempted to determine the predictors of manual skills among pre-clinical students, but consensus has yet to be reached. We hypothesized that valid and reliable occupational therapy test performance regarding indirect vision would differ between dental students and junior dentists and would explain the variance in manual skill performance in pre-clinical courses. To test this hypothesis, we applied the Purdue Pegboard test and O’Connor Tweezer Dexterity test under different conditions of direct and indirect vision. We administered these tests to students in phantom-head academic courses in 2015 and 2016 and to junior dentists. Students performed the tests at three time points: before phantom training (T0), at the end of the training (T1) and in the middle of the following year of study (T2). Dentists performed the same tests twice at 1st and 2nd trials one week apart. The results showed that indirect tasks were significantly more difficult to perform for both groups. These dexterity tests were sensitive enough to detect students’ improvement after phantom training. The dentists’ performances were significantly better than those of students at T0, specifically with regard to the use of tweezers under direct and indirect vision (the O’Connor test). A regression analysis showed that students’ manual grades obtained at the beginning of the phantom course, their performance on the Purdue test using both hands, and their performance on the O’Connor test under indirect vision predicted phantom course success in 80% of cases. The O’Connor test under indirect vision is the most informative means of monitoring and predicting the manual skills required in the pre-clinical year of dentistry studies. PMID:29518127

  17. Test Administrator's Handbook and Student Instructions for Job-Task Performance Tests for Doppler Radar, AN/APN-147 and its Computer AN/ASN-35, and Associated Test Equipment and Hand Tools. Report for June-December 1972.

    ERIC Educational Resources Information Center

    Matrix Research Co., Alexandria, VA.

    The handbook covers a comprehensive series of Job-Task Performance Tests for the Doppler Radar (AN/APN) and its Associated Computer (AN/ASN-35). The test series has been developed to measure job performance of the electronic technician. These tests encompass all phases of day-to-day preventative and corrective maintenance that technicians are…

  18. Quiet Clean Short-haul Experimental Engine (QCSEE) Under-The-Wing (UTW) engine composite nacelle test report. Volume 1: Summary, aerodynamic and mechanical performance

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The performance test results of the final under-the-wing engine configuration are presented. One hundred and six hours of engine operation were completed, including mechanical and performance checkout, baseline acoustic testing with a bellmouth inlet, reverse thrust testing, acoustic technology tests, and limited controls testing. The engine includes a variable pitch fan having advanced composite fan blades and using a ball-spline pitch actuation system.

  19. Continuous multiword recognition performance of young and elderly listeners in ambient noise

    NASA Astrophysics Data System (ADS)

    Sato, Hiroshi

    2005-09-01

    Hearing threshold shift due to aging is known as a dominant factor to degrade speech recognition performance in noisy conditions. On the other hand, cognitive factors of aging-relating speech recognition performance in various speech-to-noise conditions are not well established. In this study, two kinds of speech test were performed to examine how working memory load relates to speech recognition performance. One is word recognition test with high-familiarity, four-syllable Japanese words (single-word test). In this test, each word was presented to listeners; the listeners were asked to write the word down on paper with enough time to answer. In the other test, five continuous word were presented to listeners and listeners were asked to write the word down after just five words were presented (multiword test). Both tests were done in various speech-to-noise ratios under 50-dBA Hoth spectrum noise with more than 50 young and elderly subjects. The results of two experiments suggest that (1) Hearing level is related to scores of both tests. (2) Scores of single-word test are well correlated with those of multiword test. (3) Scores of multiword test are not improved as speech-to-noise ratio improves in the condition where scores of single-word test reach their ceiling.

  20. 40 CFR 1060.235 - What emission testing must I perform for my application for a certificate of conformity?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false What emission testing must I perform... emission testing must I perform for my application for a certificate of conformity? This section describes the emission testing you must perform to show compliance with the emission standards in subpart B of...

  1. 40 CFR 1060.235 - What emission testing must I perform for my application for a certificate of conformity?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false What emission testing must I perform... emission testing must I perform for my application for a certificate of conformity? This section describes the emission testing you must perform to show compliance with the emission standards in subpart B of...

  2. 40 CFR 1060.235 - What emission testing must I perform for my application for a certificate of conformity?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false What emission testing must I perform... emission testing must I perform for my application for a certificate of conformity? This section describes the emission testing you must perform to show compliance with the emission standards in subpart B of...

  3. 40 CFR 1060.235 - What emission testing must I perform for my application for a certificate of conformity?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false What emission testing must I perform... emission testing must I perform for my application for a certificate of conformity? This section describes the emission testing you must perform to show compliance with the emission standards in subpart B of...

  4. 40 CFR 1060.235 - What emission testing must I perform for my application for a certificate of conformity?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 33 2011-07-01 2011-07-01 false What emission testing must I perform... emission testing must I perform for my application for a certificate of conformity? This section describes the emission testing you must perform to show compliance with the emission standards in subpart B of...

  5. Direct-field acoustic testing of a flight system : logistics, challenges, and results.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stasiunas, Eric Carl; Gurule, David Joseph; Babuska, Vit

    2010-10-01

    Before a spacecraft can be considered for launch, it must first survive environmental testing that simulates the launch environment. Typically, these simulations include vibration testing performed using an electro-dynamic shaker. For some spacecraft however, acoustic excitation may provide a more severe loading environment than base shaker excitation. Because this was the case for a Sandia Flight System, it was necessary to perform an acoustic test prior to launch in order to verify survival due to an acoustic environment. Typically, acoustic tests are performed in acoustic chambers, but because of scheduling, transportation, and cleanliness concerns, this was not possible. Instead, themore » test was performed as a direct field acoustic test (DFAT). This type of test consists of surrounding a test article with a wall of speakers and controlling the acoustic input using control microphones placed around the test item, with a closed-loop control system. Obtaining the desired acoustic input environment - proto-flight random noise input with an overall sound pressure level (OASPL) of 146.7 dB-with this technique presented a challenge due to several factors. An acoustic profile with this high OASPL had not knowingly been obtained using the DFAT technique prior to this test. In addition, the test was performed in a high-bay, where floor space and existing equipment constrained the speaker circle diameter. And finally, the Flight System had to be tested without contamination of the unit, which required a contamination bag enclosure of the test unit. This paper describes in detail the logistics, challenges, and results encountered while performing a high-OASPL, direct-field acoustic test on a contamination-sensitive Flight System in a high-bay environment.« less

  6. Reliability of a standardized test in Swedish for evaluation of reading performance in healthy eyes. Interchart and test-retest analyses.

    PubMed

    Thaung, Jörgen; Olseke, Kjell; Ahl, Johan; Sjöstrand, Johan

    2014-09-01

    The purpose of our study was to establish a practical and quick test for assessing reading performance and to statistically analyse interchart and test-retest reliability of a new standardized Swedish reading chart system consisting of three charts constructed according to the principles available in the literature. Twenty-four subjects with healthy eyes, mean age 65 ± 10 years, were tested binocularly and the reading performance evaluated as reading acuity, critical print size and maximum reading speed. The test charts all consist of 12 short text sentences with a print size ranging from 0.9 to -0.2 logMAR in approximate steps of 0.1 logMAR. Two testing sessions, in two different groups (C1 and C2), were under strict control of luminance and lighting environment. Reading performance tests with chart T1, T2 and T3 were used for evaluation of interchart reliability and test data from a second session 1 month or more apart for the test-retest analysis. The testing of reading performance in adult observers with short sentences of continuous text was quick and practical. The agreement between the tests obtained with the three different test charts was high both within the same test session and at retest. This new Swedish variant of a standardized reading system based on short sentences and logarithmic progression of print size provides reliable measurements of reading performance and preliminary norms in an age group around 65 years. The reading test with three independent reading charts can be useful for clinical studies of reading ability before and after treatment. © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  7. Performance evaluation of Space Shuttle SRB parachutes from air drop and scaled model wind tunnel tests. [Solid Rocket Booster recovery system

    NASA Technical Reports Server (NTRS)

    Moog, R. D.; Bacchus, D. L.; Utreja, L. R.

    1979-01-01

    The aerodynamic performance characteristics have been determined for the Space Shuttle Solid Rocket Booster drogue, main, and pilot parachutes. The performance evaluation on the 20-degree conical ribbon parachutes is based primarily on air drop tests of full scale prototype parachutes. In addition, parametric wind tunnel tests were performed and used in parachute configuration development and preliminary performance assessments. The wind tunnel test data are compared to the drop test results and both sets of data are used to determine the predicted performance of the Solid Rocket Booster flight parachutes. Data from other drop tests of large ribbon parachutes are also compared with the Solid Rocket Booster parachute performance characteristics. Parameters assessed include full open terminal drag coefficients, reefed drag area, opening characteristics, clustering effects, and forebody interference.

  8. Who tests whom? A comprehensive overview of Chlamydia trachomatis test practices in a Dutch region among different STI care providers for urogenital, anorectal and oropharyngeal sites in young people: a cross-sectional study.

    PubMed

    den Heijer, Casper D J; van Liere, G A F S; Hoebe, C J P A; van Bergen, J E A M; Cals, J W L; Stals, F S; Dukers-Muijrers, N H T M

    2016-05-01

    To evaluate and compare Chlamydia trachomatis (CT) diagnostic test practices of different sexually transmitted infection (STI) care providers in 16-29 year olds from one defined geographic Dutch region (280,000 inhabitants). Both number and proportion of positive CT tests (ie, test positivity) were assessed, and factors associated with these outcomes. Data on laboratory testing and diagnosis of urogenital, anorectal and oropharyngeal CT between 2006 and 2010 were retrieved from general practitioners (GPs), gynaecologists, an STI clinic and a population-based chlamydia screening programme. Multivariable regression analyses explored associations between age, sex, test year, socio-economic status (SES) and STI care provider and the outcomes being the number of tests and test positivity. Overall, 22,831 tests were performed (1868 positive; 8.2%). Extragenital (ie, anorectal and oropharyngeal) tests accounted for 4% of all tests (7.5% positive) and were almost exclusively (99%) performed by the STI clinic. STI clinics tested most men (37.2% of all tested men), whereas GPs tested most women (29.9% of all tested women). GPs and STI clinics accounted for 73.3% (1326/1808) of urogenital CT diagnoses. In women, the number of tests increased with age, whereas test positivity decreased for all STI care providers. Lower SES was associated with higher test positivity in GP and gynaecology patients. STI clinics performed most CT tests in men, whereas GPs performed most CT tests in women. GPs and STI clinics accounted for the majority of positives. Extragenital CT testing is rarely performed outside the STI clinic and needs to be promoted, especially in men who have sex with men. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  9. 40 CFR 63.827 - Performance test methods.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Performance test methods. 63.827...) National Emission Standards for the Printing and Publishing Industry § 63.827 Performance test methods... test method for determining their values for approval by the Administrator in accordance with § 63.7(f...

  10. 40 CFR 62.14680 - May I conduct performance testing less often?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...

  11. 40 CFR 62.14680 - May I conduct performance testing less often?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...

  12. 40 CFR 62.14680 - May I conduct performance testing less often?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...

  13. 40 CFR 62.14680 - May I conduct performance testing less often?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...

  14. 40 CFR 62.14680 - May I conduct performance testing less often?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...

  15. Play for Performance: Using Computer Games to Improve Motivation and Test-Taking Performance

    ERIC Educational Resources Information Center

    Dennis, Alan R.; Bhagwatwar, Akshay; Minas, Randall K.

    2013-01-01

    The importance of testing, especially certification and high-stakes testing, has increased substantially over the past decade. Building on the "serious gaming" literature and the psychology "priming" literature, we developed a computer game designed to improve test-taking performance using psychological priming. The game primed…

  16. 42 CFR 493.1253 - Standard: Establishment and verification of performance specifications.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... establish performance specifications for any test system used by the laboratory before April 24, 2003. (b)(1... approved test system must do the following before reporting patient test results: (i) Demonstrate that it... following performance characteristics: (A) Accuracy. (B) Precision. (C) Reportable range of test results for...

  17. 42 CFR 493.1253 - Standard: Establishment and verification of performance specifications.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... establish performance specifications for any test system used by the laboratory before April 24, 2003. (b)(1... approved test system must do the following before reporting patient test results: (i) Demonstrate that it... following performance characteristics: (A) Accuracy. (B) Precision. (C) Reportable range of test results for...

  18. 42 CFR 493.1253 - Standard: Establishment and verification of performance specifications.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... establish performance specifications for any test system used by the laboratory before April 24, 2003. (b)(1... approved test system must do the following before reporting patient test results: (i) Demonstrate that it... following performance characteristics: (A) Accuracy. (B) Precision. (C) Reportable range of test results for...

  19. 42 CFR 493.1253 - Standard: Establishment and verification of performance specifications.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... establish performance specifications for any test system used by the laboratory before April 24, 2003. (b)(1... approved test system must do the following before reporting patient test results: (i) Demonstrate that it... following performance characteristics: (A) Accuracy. (B) Precision. (C) Reportable range of test results for...

  20. Relationships among Testing Medium, Test Performance, and Testing Time of High School Students Who Are Visually Impaired

    ERIC Educational Resources Information Center

    Erin, Jane N.; Hong, Sunggye; Schoch, Christina; Kuo, YaJu

    2006-01-01

    This study compared the test scores and time required by high school students who are blind, sighted, or have low vision to complete tests administered in written and oral formats. The quantitative results showed that the blind students performed better on multiple-choice tests in braille and needed more time while taking tests in braille. The…

  1. Chemical, Biological, and Radiological Contamination Survivability: Material Effects Testing

    DTIC Science & Technology

    2012-06-22

    form that can be compared to pretest and posttest functional performance data. If Soldiers are desired, ensure a Test Schedule and Review Committee...test execution. f. The material’s performance specification should also be reviewed before planning test execution. For example , the...test data, and conformance with specified test and operating procedures cannot be overemphasized. 3.1 Test Planning. 3.1.1 Pretest Preparation

  2. Berthing mechanism final test report and program assessment

    NASA Technical Reports Server (NTRS)

    1988-01-01

    The purpose is to document the testing performed on both hardware and software developed under the Space Station Berthing Mechanisms Program. Testing of the mechanism occurred at three locations. Several system components, e.g., actuators and computer systems, were functionally tested before assembly. A series of post assembly tests were performed. The post assembly tests, as well as the dynamic testing of the mechanism, are presented.

  3. Model-Scale Aerodynamic Performance Testing of Proposed Modifications to the NASA Langley Low Speed Aeroacoustic Wind Tunnel

    NASA Technical Reports Server (NTRS)

    Booth, Earl R., Jr.; Coston, Calvin W., Jr.

    2005-01-01

    Tests were performed on a 1/20th-scale model of the Low Speed Aeroacoustic Wind Tunnel to determine the performance effects of insertion of acoustic baffles in the tunnel inlet, replacement of the existing collector with a new collector design in the open jet test section, and addition of flow splitters to the acoustic baffle section downstream of the test section. As expected, the inlet baffles caused a reduction in facility performance. About half of the performance loss was recovered by addition the flow splitters to the downstream baffles. All collectors tested reduced facility performance. However, test chamber recirculation flow was reduced by the new collector designs and shielding of some of the microphones was reduced owing to the smaller size of the new collector. Overall performance loss in the facility is expected to be a 5 percent top flow speed reduction, but the facility will meet OSHA limits for external noise levels and recirculation in the test section will be reduced.

  4. Biorelevant in vitro performance testing of orally administered dosage forms-workshop report.

    PubMed

    Reppas, Christos; Friedel, Horst-Dieter; Barker, Amy R; Buhse, Lucinda F; Cecil, Todd L; Keitel, Susanne; Kraemer, Johannes; Morris, J Michael; Shah, Vinod P; Stickelmeyer, Mary P; Yomota, Chikako; Brown, Cynthia K

    2014-07-01

    Biorelevant in vitro performance testing of orally administered dosage forms has become an important tool for the assessment of drug product in vivo behavior. An in vitro performance test which mimics the intraluminal performance of an oral dosage form is termed biorelevant. Biorelevant tests have been utilized to decrease the number of in vivo studies required during the drug development process and to mitigate the risk related to in vivo bioequivalence studies. This report reviews the ability of current in vitro performance tests to predict in vivo performance and generate successful in vitro and in vivo correlations for oral dosage forms. It also summarizes efforts to improve the predictability of biorelevant tests. The report is based on the presentations at the 2013 workshop, Biorelevant In Vitro Performance Testing of Orally Administered Dosage Forms, in Washington, DC, sponsored by the FIP Dissolution/Drug Release Focus Group in partnership with the American Association of Pharmaceutical Scientists (AAPS) and a symposium at the AAPS 2012 Annual meeting on the same topic.

  5. [Research progress on mechanical performance evaluation of artificial intervertebral disc].

    PubMed

    Li, Rui; Wang, Song; Liao, Zhenhua; Liu, Weiqiang

    2018-03-01

    The mechanical properties of artificial intervertebral disc (AID) are related to long-term reliability of prosthesis. There are three testing methods involved in the mechanical performance evaluation of AID based on different tools: the testing method using mechanical simulator, in vitro specimen testing method and finite element analysis method. In this study, the testing standard, testing equipment and materials of AID were firstly introduced. Then, the present status of AID static mechanical properties test (static axial compression, static axial compression-shear), dynamic mechanical properties test (dynamic axial compression, dynamic axial compression-shear), creep and stress relaxation test, device pushout test, core pushout test, subsidence test, etc. were focused on. The experimental techniques using in vitro specimen testing method and testing results of available artificial discs were summarized. The experimental methods and research status of finite element analysis were also summarized. Finally, the research trends of AID mechanical performance evaluation were forecasted. The simulator, load, dynamic cycle, motion mode, specimen and test standard would be important research fields in the future.

  6. A PILOT STUDY OF CORE STABILITY AND ATHLETIC PERFORMANCE: IS THERE A RELATIONSHIP?

    PubMed Central

    Sharrock, Chris; Cropper, Jarrod; Mostad, Joel; Johnson, Matt

    2011-01-01

    Study Design: Correlation study Objectives: To objectively evaluate the relationship between core stability and athletic performance measures in male and female collegiate athletes. Background: The relationship between core stability and athletic performance has yet to be quantified in the available literature. The current literature does not demonstrate whether or not core strength relates to functional performance. Questions remain regarding the most important components of core stability, the role of sport specificity, and the measurement of core stability in relation to athletic performance. Methods: A sample of 35 volunteer student athletes from Asbury College (NAIA Division II) provided informed consent. Participants performed a series of five tests: double leg lowering (core stability test), the forty yard dash, the T-test, vertical jump, and a medicine ball throw. Participants performed three trials of each test in a randomized order. Results: Correlations between the core stability test and each of the other four performance tests were determined using a General Linear Model. Medicine ball throw negatively correlated to the core stability test (r –0.389, p=0.023). Participants that performed better on the core stability test had a stronger negative correlation to the medicine ball throw (r =–0.527). Gender was the most strongly correlated variable to core strength, males with a mean measurement of double leg lowering of 47.43 degrees compared to females having a mean of 54.75 degrees. Conclusions: There appears to be a link between a core stability test and athletic performance tests; however, more research is needed to provide a definitive answer on the nature of this relationship. Ideally, specific performance tests will be able to better define and to examine relationships to core stability. Future studies should also seek to determine if there are specific sub-categories of core stability which are most important to allow for optimal training and performance for individual sports. PMID:21713228

  7. Implementation and performance test of cloud platform based on Hadoop

    NASA Astrophysics Data System (ADS)

    Xu, Jingxian; Guo, Jianhong; Ren, Chunlan

    2018-01-01

    Hadoop, as an open source project for the Apache foundation, is a distributed computing framework that deals with large amounts of data and has been widely used in the Internet industry. Therefore, it is meaningful to study the implementation of Hadoop platform and the performance of test platform. The purpose of this subject is to study the method of building Hadoop platform and to study the performance of test platform. This paper presents a method to implement Hadoop platform and a test platform performance method. Experimental results show that the proposed test performance method is effective and it can detect the performance of Hadoop platform.

  8. Orion Launch Abort System Jettison Motor Performance During Exploration Flight Test 1

    NASA Technical Reports Server (NTRS)

    McCauley, Rachel J.; Davidson, John B.; Winski, Richard G.

    2015-01-01

    This paper presents an overview of the flight test objectives and performance of the Orion Launch Abort System during Exploration Flight Test-1. Exploration Flight Test-1, the first flight test of the Orion spacecraft, was managed and led by the Orion prime contractor, Lockheed Martin, and launched atop a United Launch Alliance Delta IV Heavy rocket. This flight test was a two-orbit, high-apogee, high-energy entry, low-inclination test mission used to validate and test systems critical to crew safety. This test included the first flight test of the Launch Abort System performing Orion nominal flight mission critical objectives. Although the Orion Program has tested a number of the critical systems of the Orion spacecraft on the ground, the launch environment cannot be replicated completely on Earth. Data from this flight will be used to verify the function of the jettison motor to separate the Launch Abort System from the crew module so it can continue on with the mission. Selected Launch Abort System flight test data is presented and discussed in the paper. Through flight test data, Launch Abort System performance trends have been derived that will prove valuable to future flights as well as the manned space program.

  9. The relationship between neuropsychological tests of visuospatial function and lobar cortical thickness.

    PubMed

    Zink, Davor N; Miller, Justin B; Caldwell, Jessica Z K; Bird, Christopher; Banks, Sarah J

    2018-06-01

    Tests of visuospatial function are often administered in comprehensive neuropsychological evaluations. These tests are generally considered assays of parietal lobe function; however, the neural correlates of these tests, using modern imaging techniques, are not well understood. In the current study we investigated the relationship between three commonly used tests of visuospatial function and lobar cortical thickness in each hemisphere. Data from 374 patients who underwent a neuropsychological evaluation and MRI scans in an outpatient dementia clinic were included in the analysis. We examined the relationships between cortical thickness, as assessed with Freesurfer, and performance on three tests: Judgment of Line Orientation (JoLO), Block Design (BD) from the Fourth edition of the Wechsler Adult Intelligence Scale, and Brief Visuospatial Memory Test-Revised Copy Trial (BVMT-R-C) in patients who showed overall average performance on these tasks. Using a series of multiple regression models, we assessed which lobe's overall cortical thickness best predicted test performance. Among the individual lobes, JoLO performance was best predicted by cortical thickness in the right temporal lobe. BD performance was best predicted by cortical thickness in the right parietal lobe, and BVMT-R-C performance was best predicted by cortical thickness in the left parietal lobe. Performance on constructional tests of visuospatial function appears to correspond best with underlying cortical thickness of the parietal lobes, while performance on visuospatial judgment tests appears to correspond best to temporal lobe thickness. Future research using voxel-wise and connectivity techniques and including more diverse samples will help further understanding of the regions and networks involved in visuospatial tests.

  10. Pyrovalve Blowby Tests

    NASA Technical Reports Server (NTRS)

    Saulsberry, Regor; Keddy, Christopher P.; Julien, Howard L.

    2003-01-01

    The NASA White Sands Test Facility (WSTF) was requested to perform pyrovalve blowby tests in support of the Mars Observer Propulsion and Corrective Actions Test Program. Fifty-three tests were conducted in an attempt to characterize the blowby of commercial pyrovalves. Those pyrovalves used on NASA spacecraft are well represented, and the test data reported provide a basis for evaluating the performance of similar valves in other propulsion systems. The three test series conducted are subsequently described. All testing was done in the same test facility, with periodic changes that enhanced the test methodology.

  11. Can more than one incremental cycling test be performed within one day?

    PubMed

    Scharhag-Rosenberger, Friederike; Carlsohn, Anja; Lundby, Carsten; Schüler, Stefan; Mayer, Frank; Scharhag, Jürgen

    2014-01-01

    Changes in performance parameters over four consecutive maximal incremental cycling tests were investigated to determine how many tests can be performed within one single day without negatively affecting performance. Sixteen male and female subjects (eight trained (T): 25 ± 3 yr, BMI 22.6 ± 2.5 kg·m(-2), maximal power output (P(max)) 4.6 ± 0.5 W·kg(-1); eight untrained (UT): 27 ± 3 yr, BMI 22.3 ± 1.2 kg·m(-2), P(max) 2.9 ± 0.3 W·kg(-1)) performed four successive maximal incremental cycling tests separated by 1.5 h of passive rest. Individual energy requirements were covered by standardised meals between trials. Maximal oxygen uptake (VO(2max)) remained unchanged over the four tests in both groups (P = 0.20 and P = 0.33, respectively). P(max) did not change in the T group (P = 0.32), but decreased from the third test in the UT group (P < 0.01). Heart rate responses to submaximal exercise were elevated from the third test in the T group and from the second test in the UT group (P < 0.05). The increase in blood lactate shifted rightward over the four tests in both groups (P < 0.001 and P < 0.01, respectively). Exercise-induced net increases in epinephrine and norepinephrine were not different between the tests in either group (P ≥ 0.15). If VO(2max) is the main parameter of interest, trained and untrained individuals can perform at least four maximal incremental cycling tests per day. However, because other parameters changed after the first and second test, respectively, no more than one test per day should be performed if parameters other than VO(2max) are the prime focus.

  12. 42 CFR 493.845 - Standard; Toxicology.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the... testing event. (e)(1) For any unsatisfactory analyte or test performance or testing event for reasons... any unacceptable analyte or testing event score, remedial action must be taken and documented, and the...

  13. 42 CFR 493.851 - Standard; Hematology.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the... testing event. (e)(1) For any unsatisfactory analyte or test performance or testing event for reasons... any unacceptable analyte or testing event score, remedial action must be taken and documented, and the...

  14. 42 CFR 493.843 - Standard; Endocrinology.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the... testing event. (e)(1) For any unsatisfactory analyte or test performance or testing event for reasons... any unacceptable analyte or testing event score, remedial action must be taken and documented, and the...

  15. 42 CFR 493.845 - Standard; Toxicology.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the... testing event. (e)(1) For any unsatisfactory analyte or test performance or testing event for reasons... any unacceptable analyte or testing event score, remedial action must be taken and documented, and the...

  16. 42 CFR 493.845 - Standard; Toxicology.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the... testing event. (e)(1) For any unsatisfactory analyte or test performance or testing event for reasons... any unacceptable analyte or testing event score, remedial action must be taken and documented, and the...

  17. 42 CFR 493.851 - Standard; Hematology.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the... testing event. (e)(1) For any unsatisfactory analyte or test performance or testing event for reasons... any unacceptable analyte or testing event score, remedial action must be taken and documented, and the...

  18. 42 CFR 493.843 - Standard; Endocrinology.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the... testing event. (e)(1) For any unsatisfactory analyte or test performance or testing event for reasons... any unacceptable analyte or testing event score, remedial action must be taken and documented, and the...

  19. 42 CFR 493.843 - Standard; Endocrinology.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the... testing event. (e)(1) For any unsatisfactory analyte or test performance or testing event for reasons... any unacceptable analyte or testing event score, remedial action must be taken and documented, and the...

  20. 42 CFR 493.851 - Standard; Hematology.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the... testing event. (e)(1) For any unsatisfactory analyte or test performance or testing event for reasons... any unacceptable analyte or testing event score, remedial action must be taken and documented, and the...

  1. J-2X Fuel Turbopump Point of Departure: The Performance of the J-2s Fuel Turbopump Inducer

    NASA Technical Reports Server (NTRS)

    Sargent, S. R.; Becht, D. G.; Mulder, A. D.

    2008-01-01

    To aid the J-2X program design effort with detailed performance and environment information, the J-2S fuel turbopump (FTP) inducer has undergone a thorough test series in both water and hydrogen. The test series utilizes both inducer only and a complete pump configuration to assess the inducer interaction to the overall turbopump system. The test goals include verification of suction performance against heritage J-2S data, head production, effects of thermodynamic suppression head (TSH), and evaluation of the inducer dynamic pressure caused by cavitation instabilities. Test facilities at both Pratt & Whitney Rocketdyne (PWR) and NASA s Stennis Space Center (SSC) are employed for the testing. The inducer only water test effort conducted at PWR established performance curves for suction performance, head production, and efficiency over a wide operating range. Because the heritage J-2S suction performance data set is in hydrogen, it is desired to obtain current suction performance data in hydrogen as well, thus avoiding the reliance on a theoretical TSH correlation for direct comparison. This data then provides an empirically based TSH correlation allowing for the comparison of water test suction data to system suction requirements. The FTP testing performed at SSC provides these suction performance relationships as well as inlet duct dynamic pressures during liquid hydrogen operation. The test effort successfully confirms the heritage J-2S suction performance and establishes the amount of TSH between water and hydrogen operation at the design flow coefficient. Correlating data is also obtained for cavitating instability frequency content, illustrating the validity of using the wide flow range water test data to predict hydrogen performance.

  2. Rise time and response measurements on a LiSOCl2 cell

    NASA Technical Reports Server (NTRS)

    Bastien, Caroline; Lecomte, Eric J.

    1992-01-01

    Dynamic impedance tests were performed on a 180 Ah LiSOCl2 cell in the frame of a short term work contract awarded by Aerospatiale as part of the Hermes Space Plane development work. These tests consisted of rise time and response measurements. The rise time test was performed to show the ability to deliver 4 KW, in the nominal voltage range (75-115 V), within less than 100 microseconds, and after a period at rest of 13 days. The response measurements test consisted of step response and frequency response tests. The frequency response test was performed to characterize the response of the LiSOCl2 cell to a positive or negative load step of 10 A starting from various currents. The test was performed for various depths of discharge and various temperatures. The test results were used to build a mathematical, electrical model of the LiSOCl2 cell which are also presented. The test description, test results, electrical modelization description, and conclusions are presented.

  3. Full-scale transmission testing to evaluate advanced lubricants

    NASA Technical Reports Server (NTRS)

    Lewicki, David G.; Decker, Harry J.; Shimski, John T.

    1992-01-01

    Experimental tests were performed on the OH-58A helicopter main rotor transmission in the NASA Lewis 500 hp helicopter transmission test stand. The testing was part of a lubrication program. The objectives are to develop and show a separate lubricant for gearboxes with improved performance in life and load carrying capacity. The goal was to develop a testing procedure to fail certain transmission components using a MIL-L-23699 based reference oil and then to run identical tests with improved lubricants and show improved performance. The tests were directed at parts that failed due to marginal lubrication from Navy field experience. These failures included mast shaft bearing micropitting, sun gear and planet bearing fatigue, and spiral bevel gear scoring. A variety of tests were performed and over 900 hrs of total run time accumulated for these tests. Some success was achieved in developing a testing procedure to produce sun gear and planet bearing fatigue failures. Only marginal success was achieved in producing mast shaft bearing micropitting and spiral bevel gear scoring.

  4. The relationships between pesticide metabolites and neurobehavioral test performance in the third National Health and Nutrition Examination Survey.

    PubMed

    Krieg, Edward F

    2013-01-01

    Regression analysis was used to estimate and test for relationships between urinary pesticide metabolites and neurobehavioral test performance in adults, 20 to 59 years old, participating in the third National Health and Nutrition Examination Survey. The 12 pesticide metabolites included 2 naphthols, 8 phenols, a phenoxyacetic acid, and a pyridinol. The 3 neurobehavioral tests included in the survey were simple reaction time, symbol-digit substitution, and serial digit learning. As the 2,4-dichlorophenol, 2,5-dichlorophenol, and the pentachlorophenol concentrations increased, performance on the serial digit learning test improved. As the 2,5-dichlorophenol concentration increased, performance on the symbol-digit substitution test improved. At low concentrations, the parent compounds of these metabolites may act at acetylcholine and γ-aminobutyric acid synapses in the central nervous system to improve neurobehavioral test performance.

  5. Analytical design and performance studies of nuclear furnace tests of small nuclear light bulb models

    NASA Technical Reports Server (NTRS)

    Latham, T. S.; Rodgers, R. J.

    1972-01-01

    Analytical studies were continued to identify the design and performance characteristics of a small-scale model of a nuclear light bulb unit cell suitable for testing in a nuclear furnace reactor. Emphasis was placed on calculating performance characteristics based on detailed radiant heat transfer analyses, on designing the test assembly for ease of insertion, connection, and withdrawal at the reactor test cell, and on determining instrumentation and test effluent handling requirements. In addition, a review of candidate test reactors for future nuclear light bulb in-reactor tests was conducted.

  6. Research notes : solar powered markers not up to challenge.

    DOT National Transportation Integrated Search

    2008-06-01

    ODOT performed preliminary tests on eight different models of solar powered raised pavement markers. These included environmental tests (extreme temperatures, immersion), optical performance tests, and observation tests. Federal Highway Administratio...

  7. When we test, do we stress? Impact of the testing environment on cortisol secretion and memory performance in older adults.

    PubMed

    Sindi, Shireen; Fiocco, Alexandra J; Juster, Robert-Paul; Pruessner, Jens; Lupien, Sonia J

    2013-08-01

    The majority of studies find that older adults have worse memory performance than young adults. However, contextual features in the testing environment may be perceived as stressful by older adults, increasing their stress hormone levels. Given the evidence that older adults are highly sensitive to the effects of stress hormones (cortisol) on memory performance, it is postulated that a stressful testing environment in older adults can lead to an acute stress response and to memory impairments. The current study compared salivary cortisol levels and memory performance in young and older adults tested in environments manipulated to be stressful (unfavourable condition) or not stressful (favourable condition) for each age group. 28 young adults and 32 older adults were tested in two testing conditions: (1) a condition favouring young adults (constructed to be less stressful for young adults), and (2) a condition favouring older adults (constructed to be less stressful for older adults). The main outcome measure was salivary cortisol levels. Additionally, immediate and delayed memory performances were assessed during each condition. In older adults only, we found significantly high cortisol levels and low memory performance in the condition favouring young adults. In contrast, cortisol levels were lower and memory performance was better when older adults were tested in conditions favouring them. There was no effect of testing condition in young adults. The results demonstrate that older adults' memory performance is highly sensitive to the testing environment. These findings have important implications for both research and clinical settings in which older adults are tested for memory performance. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Testing of small and large sign support systems FOIL test number : 92F017

    DOT National Transportation Integrated Search

    1994-07-01

    This test report contains the results of a crash test performed at the Federal Outdoor Impact Laboratory (FOIL) in McLean, Virginia. The test was performed on a small sign support system at 20 mi/h (8.9 m/s), test 92F017. The vehicle used for this te...

  9. 40 CFR 86.1430 - Certification Short Test sequence; general requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... test procedure. Fuel tank drain and fill is performed or a transient test procedure is performed, as... sets of test conditions identified in this subpart are based on the test fuel type present in the vehicle fuel tank and the ambient temperature during the test. Tables O-96-1 and O-96-2 outline the...

  10. 40 CFR 86.1430 - Certification Short Test sequence; general requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... test procedure. Fuel tank drain and fill is performed or a transient test procedure is performed, as... sets of test conditions identified in this subpart are based on the test fuel type present in the vehicle fuel tank and the ambient temperature during the test. Tables O-96-1 and O-96-2 outline the...

  11. 40 CFR 86.1430 - Certification Short Test sequence; general requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... test procedure. Fuel tank drain and fill is performed or a transient test procedure is performed, as... sets of test conditions identified in this subpart are based on the test fuel type present in the vehicle fuel tank and the ambient temperature during the test. Tables O-96-1 and O-96-2 outline the...

  12. 40 CFR 86.1430 - Certification Short Test sequence; general requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... test procedure. Fuel tank drain and fill is performed or a transient test procedure is performed, as... sets of test conditions identified in this subpart are based on the test fuel type present in the vehicle fuel tank and the ambient temperature during the test. Tables O-96-1 and O-96-2 outline the...

  13. Testing of small and large sign support systems FOIL test number : 92F026

    DOT National Transportation Integrated Search

    1994-07-01

    This test report contains the results of a crash test performed at the Federal Outdoor Impact Laboratory (FOIL) in McLean, Virginia. The test was performed on a small sign support system at 20 mi/h (8.9 m/s), test 92F026. The vehicle used for this te...

  14. Testing of small and large sign support systems FOIL test number : 92F018

    DOT National Transportation Integrated Search

    1994-07-01

    This test report contains the results of a crash test performed at the Federal Outdoor Impact Laboratory (FOIL) in McLean, Virginia. The test was performed on a small sign support system at 20 mi/h (8.9 m/s), test 92F018. The vehicle used for this te...

  15. Testing of small and large sign support systems FOIL test number : 92F015

    DOT National Transportation Integrated Search

    1994-07-01

    This test report contains the results of a crash test performed at the Federal Outdoor Impact Laboratory (FOIL) in McLean, Virginia. The test was performed on a small sign support system at 20 mi/h (8.9 m/s), test 92F015. The vehicle used for these t...

  16. Testing of small and large sign support systems FOIL test number : 92F012

    DOT National Transportation Integrated Search

    1994-07-01

    This test report contains the results of a crash test performed at the Federal Outdoor Impact Laboratory (FOIL) in McLean, Virginia. The test was performed on a small sign support system at 20 mi/h (8.9 m/s), test 92F012. The vehicle used for these t...

  17. Testing of small and large sign support systems FOIL test number : 92F023

    DOT National Transportation Integrated Search

    1994-07-01

    This test report contains the results of a crash test performed at the Federal Outdoor Impact Laboratory (FOIL) in McLean, Virginia. The test was performed on a small sign support system at 20 mi/h (8.9 m/s), test 92F023. The vehicle used for this te...

  18. Testing of small and large sign support systems FOIL test number : 92F019

    DOT National Transportation Integrated Search

    1994-07-01

    This test report contains the results of a crash test performed at the Federal Outdoor Impact Laboratory (FOIL) in McLean, Virginia. The test was performed on a small sign support system at 20 mi/h (8.9 m/s), test 92F019. The vehicle used for this te...

  19. Testing of small and large sign support systems FOIL test number : 92F014

    DOT National Transportation Integrated Search

    1994-07-01

    This test report contains the results of a crash test performed at the Federal Outdoor Impact Laboratory (FOIL) in McLean, Virginia. The test was performed on a small sign support system at 20 mi/h (8.9 m/s), test 92F014. The vehicle used for these t...

  20. Technical Evaluation Motor No. 7 (TEM-07)

    NASA Technical Reports Server (NTRS)

    Hugh, Phil

    1991-01-01

    Technical Evaluation Motor Number 7 (TEM-7) was a full scale, full-duration static test firing of a high performance motor (HPM) configuration solid rocket motor (SRM) with nozzle vectoring. The static test fire occurred on 11 December 1990 at the Thiokol Corporation Static Test Bay T-97. Documented here are the procedures, performance, and results available through 22 January 1991. Critical post test hardware activities and assessment of the test data are not complete. A completed test report will be submitted 60 days after the test date. Included here is a presentation and discussion of the TEM-7 performance, anomalies, and test result concurrence with the objectives outlined in CTP-0107 Revision A, Space Shuttle Technical Evaluation Motor number 7 (TEM-07) Static Fire Test Plan.

  1. Frequency modulation system test procedure shuttle task 501 approach and landing test configuration

    NASA Technical Reports Server (NTRS)

    Doland, G. D.

    1976-01-01

    Shuttle Task 501 is an in-line task to test the performance and compatibility of radiofrequency links between the SSO and ground, and relay via a satellite. Under Shuttle Task 501 approach and landing test (ALT) phase only a limited portion of the communication and tracking (C&T) equipment is to be tested. The principal item to be tested is a frequency modulated (FM) data link. To test this RF link, an ALT FM System was designed, constructed, and the console wiring verified. A step-by-step procedure to be used to perform the ALT FM system is presented. The ALT FM system test is to be performed prior to delivery of the equipment to the Electronic Systems Test Laboratory (ESTL).

  2. The yo-yo intermittent recovery test: physiological response, reliability, and validity.

    PubMed

    Krustrup, Peter; Mohr, Magni; Amstrup, Tommas; Rysgaard, Torben; Johansen, Johnny; Steensberg, Aadam; Pedersen, Preben K; Bangsbo, Jens

    2003-04-01

    To examine the physiological response and reproducibility of the Yo-Yo intermittent recovery test and its application to elite soccer. Heart rate was measured, and metabolites were determined in blood and muscle biopsies obtained before, during, and after the Yo-Yo test in 17 males. Physiological measurements were also performed during a Yo-Yo retest and an exhaustive incremental treadmill test (ITT). Additionally, 37 male elite soccer players performed two to four seasonal tests, and the results were related to physical performance in matches. The test-retest CV for the Yo-Yo test was 4.9%. Peak heart rate was similar in ITT and Yo-Yo test (189 +/- 2 vs 187 +/- 2 bpm), whereas peak blood lactate was higher (P < 0.05) in the Yo-Yo test. During the Yo-Yo test, muscle lactate increased eightfold (P < 0.05) and muscle creatine phosphate (CP) and glycogen decreased (P < 0.05) by 51% and 23%, respectively. No significant differences were observed in muscle CP, lactate, pH, or glycogen between 90 and 100% of exhaustion time. During the precompetition period, elite soccer players improved (P < 0.05) Yo-Yo test performance and maximum oxygen uptake ([OV0312]O(2max)) by 25 +/- 6 and 7 +/- 1%, respectively. High-intensity running covered by the players during games was correlated to Yo-Yo test performance (r = 0.71, P < 0.05) but not to [OV0312]O(2max) and ITT performance. The test had a high reproducibility and sensitivity, allowing for detailed analysis of the physical capacity of athletes in intermittent sports. Specifically, the Yo-Yo intermittent recovery test was a valid measure of fitness performance in soccer. During the test, the aerobic loading approached maximal values, and the anaerobic energy system was highly taxed. Additionally, the study suggests that fatigue during intense intermittent short-term exercise was unrelated to muscle CP, lactate, pH, and glycogen.

  3. Reliability, validity and description of timed performance of the Jebsen-Taylor Test in patients with muscular dystrophies.

    PubMed

    Artilheiro, Mariana Cunha; Fávero, Francis Meire; Caromano, Fátima Aparecida; Oliveira, Acary de Souza Bulle; Carvas, Nelson; Voos, Mariana Callil; Sá, Cristina Dos Santos Cardoso de

    2017-12-08

    The Jebsen-Taylor Test evaluates upper limb function by measuring timed performance on everyday activities. The test is used to assess and monitor the progression of patients with Parkinson disease, cerebral palsy, stroke and brain injury. To analyze the reliability, internal consistency and validity of the Jebsen-Taylor Test in people with Muscular Dystrophy and to describe and classify upper limb timed performance of people with Muscular Dystrophy. Fifty patients with Muscular Dystrophy were assessed. Non-dominant and dominant upper limb performances on the Jebsen-Taylor Test were filmed. Two raters evaluated timed performance for inter-rater reliability analysis. Test-retest reliability was investigated by using intraclass correlation coefficients. Internal consistency was assessed using the Cronbach alpha. Construct validity was conducted by comparing the Jebsen-Taylor Test with the Performance of Upper Limb. The internal consistency of Jebsen-Taylor Test was good (Cronbach's α=0.98). A very high inter-rater reliability (0.903-0.999), except for writing with an Intraclass correlation coefficient of 0.772-1.000. Strong correlations between the Jebsen-Taylor Test and the Performance of Upper Limb Module were found (rho=-0.712). The Jebsen-Taylor Test is a reliable and valid measure of timed performance for people with Muscular Dystrophy. Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.

  4. Exploration of task performance tests in a physics laboratory

    NASA Astrophysics Data System (ADS)

    Liu, Dan; El Turkey, Houssein

    2017-11-01

    In this article, we investigate the implementation of task performance tests in an undergraduate physics laboratory. Two performance tests were carried out over two semesters using the task of building a DC circuit. The first implementation in Spring 2014 had certain concerns such as the privacy of students’ testing and their ‘trial and error’ attempts. These concerns were addressed in Fall 2015 through implementing a second performance test. The second implementation was administered differently but the content of the two tests was the same. We discuss the validity of both implementations and present the correlation (or lack of) between the time that students needed to complete the tests and their grades from a paper-based laboratory assessment method.

  5. 40 CFR 600.207-12 - Calculation and use of vehicle-specific 5-cycle-based fuel economy and CO2 emission values for...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... economy and CO2 emission values from the tests performed using gasoline or diesel test fuel. (ii) Calculate the 5-cycle city and highway fuel economy and CO2 emission values from the tests performed using alcohol or natural gas test fuel, if 5-cycle testing has been performed. Otherwise, the procedure in § 600...

  6. 40 CFR 600.209-12 - Calculation of vehicle-specific 5-cycle fuel economy and CO2 emission values for a model type.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... city and highway fuel economy and CO2 emission values from the tests performed using gasoline or diesel test fuel. (ii) If 5-cycle testing was performed on the alcohol or natural gas test fuel, calculate the city and highway fuel economy and CO2 emission values from the tests performed using alcohol or natural...

  7. 40 CFR 600.209-12 - Calculation of vehicle-specific 5-cycle fuel economy and CO2 emission values for a model type.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... city and highway fuel economy and CO2 emission values from the tests performed using gasoline or diesel test fuel. (ii) If 5-cycle testing was performed on the alcohol or natural gas test fuel, calculate the city and highway fuel economy and CO2 emission values from the tests performed using alcohol or natural...

  8. 40 CFR 600.207-12 - Calculation and use of vehicle-specific 5-cycle-based fuel economy and CO2 emission values for...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... economy and CO2 emission values from the tests performed using gasoline or diesel test fuel. (ii) Calculate the 5-cycle city and highway fuel economy and CO2 emission values from the tests performed using alcohol or natural gas test fuel, if 5-cycle testing has been performed. Otherwise, the procedure in § 600...

  9. 40 CFR 600.209-12 - Calculation of vehicle-specific 5-cycle fuel economy and CO2 emission values for a model type.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... city and highway fuel economy and CO2 emission values from the tests performed using gasoline or diesel test fuel. (ii) If 5-cycle testing was performed on the alcohol or natural gas test fuel, calculate the city and highway fuel economy and CO2 emission values from the tests performed using alcohol or natural...

  10. 40 CFR 600.207-12 - Calculation and use of vehicle-specific 5-cycle-based fuel economy and CO2 emission values for...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... economy and CO2 emission values from the tests performed using gasoline or diesel test fuel. (ii) Calculate the 5-cycle city and highway fuel economy and CO2 emission values from the tests performed using alcohol or natural gas test fuel, if 5-cycle testing has been performed. Otherwise, the procedure in § 600...

  11. Is one trial enough for repeated testing? Same-day assessments of walking, mobility and fine hand use in people with myotonic dystrophy type 1.

    PubMed

    Kierkegaard, Marie; Petitclerc, Emilie; Hébert, Luc J; Gagnon, Cynthia

    2017-02-01

    Performance-based assessments of physical function are essential in people with myotonic dystrophy type 1 (DM1) to monitor disease progression and evaluate interventions. Commonly used are the six-minute walk test, the 10 m-walk test, the timed up-and-go test, the timed-stands test, grip strength tests and the nine-hole peg test. The number of trials needed on a same-day test occasion and whether the first, best or average of trials should be reported as result is unknown. Thus, the aim was to describe and explore differences between trials in these measures of walking, mobility and fine hand use in 70 adults with DM1. Three trials were performed for each test except for the six-minute walk test where two trials were allowed. There were statistical significant differences over trials in all tests except for the 10 m-walk test and grip strength tests. Pair-wise comparisons showed that the second and third trials were in general better than the first, although effect sizes were small. At which trial the individuals performed their best differed between individuals and tests. People with severe muscular impairment had difficulties to perform repeated trials. Intraclass correlation coefficients were all high in analyses exploring how to report results. The conclusion and clinical implication is that, for a same-day test occasion, one trial is sufficient for the 10 m-walk test and grip strength tests, and that repeated trials should be allowed in the timed up-and-go test, timed-stands test and nine-hole peg tests. We recommend that two trials are performed for these latter tests as such a protocol could accommodate people with various levels of impairments and physical limitations. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Developing measures of fatigue using an alcohol comparison to validate the effects of fatigue on performance.

    PubMed

    Williamson, A M; Feyer, A M; Mattick, R P; Friswell, R; Finlay-Brown, S

    2001-05-01

    The effects of 28 h of sleep deprivation were compared with varying doses of alcohol up to 0.1% blood alcohol concentration (BAC) in the same subjects. The study was conducted in the laboratory. Twenty long-haul truck drivers and 19 people not employed as professional drivers acted as subjects. Tests were selected that were likely to be affected by fatigue, including simple reaction time, unstable tracking, dual task, Mackworth clock vigilance test, symbol digit coding, visual search, sequential spatial memory and logical reasoning. While performance effects were seen due to alcohol for all tests, sleep deprivation affected performance on most tests, but had no effect on performance on the visual search and logical reasoning tests. Some tests showed evidence of a circadian rhythm effect on performance, in particular, simple reaction time, dual task, Mackworth clock vigilance, and symbol digit coding, but only for response speed and not response accuracy. Drivers were slower but more accurate than controls on the symbol digit test, suggesting that they took a more conservative approach to performance of this test. This study demonstrated which tests are most sensitive to sleep deprivation and fatigue. The study therefore has established a set of tests that can be used in evaluations of fatigue and fatigue countermeasures.

  13. Common pressure vessel battery performance

    NASA Technical Reports Server (NTRS)

    Otzinger, B.

    1978-01-01

    Performance tests run on two common pressure vessel type nickel hydrogen batteries are described and the results presented. The study included: (1) charge retention tests, (2) synchronous eclipse season cycling tests, and (3) temperature differential tests.

  14. PDSS/IMC qualification test software acceptance procedures

    NASA Technical Reports Server (NTRS)

    1984-01-01

    Tests to be performed for qualifying the payload development support system image motion compensator (IMC) are identified. The performance of these tests will verify the IMC interfaces and thereby verify the qualification test software.

  15. The influence of shyness on children's test performance.

    PubMed

    Crozier, W Ray; Hostettler, Kirsten

    2003-09-01

    Research has shown that shy children differ from their peers not only in their use of language in routine social encounters but also in formal assessments of their language development, including psychometric tests of vocabulary. There has been little examination of factors contributing to these individual differences. To investigate cognitive-competence and social anxiety interpretations of differences in children's performance on tests of vocabulary. To examine the performance of shy and less shy children under different conditions of test administration, individually with an examiner or among their peers within the familiar classroom setting. The sample consisted of 240 Year 5 pupils (122 male, 118 female) from 24 primary schools. Shy and less shy children, identified by teacher nomination and checklist ratings, completed vocabulary and mental arithmetic tests in one of three conditions, in a between-subjects design. The conditions varied individual and group administration, and oral and written responses. The conditions of test administration influenced the vocabulary test performance of shy children. They performed significantly more poorly than their peers in the two face-to-face conditions but not in the group test condition. A comparable trend for the arithmetic test was not statistically significant. Across the sample as a whole, shyness correlated significantly with test scores. Shyness does influence children's cognitive test performance and its impact is larger when children are tested face-to-face rather than in a more anonymous group setting. The results are of significance for theories of shyness and have implications for the assessment of schoolchildren.

  16. Evaluation of a Novel Single-Tube Method for Extended Genotyping of Human Papillomavirus

    PubMed Central

    Serrano, I.; Wennington, H.; Graham, C.; Cubie, H.; Boland, E.; Fu, G.; Cuschieri, K.

    2017-01-01

    ABSTRACT The use of high-risk human papillomavirus (HPV) testing for surveillance and clinical applications is increasing globally, and it is important that tests are evaluated to ensure they are fit for this purpose. In this study, the performance of a new HPV genotyping test, the Papilloplex high-risk HPV (HR-HPV) test, was compared to two well-established genotyping tests. Preliminary clinical performance was also ascertained for the detection of CIN2+ in a disease-enriched retrospective cohort. A panel of 500 cervical liquid-based cytology samples with known clinical outcomes were tested by the Papilloplex HR-HPV test. Analytical concordance was compared to two assays: a Linear Array (LA) HPV genotyping test and an Optiplex HPV genotyping test. The initial clinical performance for the detection for CIN2+ samples was performed and compared to that of two clinically validated HPV tests: a RealTime High-Risk HPV test (RealTime) and a Hybrid Capture 2 HPV test (HC2). High agreement for HR-HPV was observed between the Papilloplex and LA and Optiplex HPV tests (97 and 95%, respectively), with kappa values for HPV16 and HPV18 being 0.90 and 0.81 compared to the LA and 0.70 and 0.82 compared to the Optiplex test. The sensitivity, specificity, positive predictive value, and negative predictive value of the Papilloplex test for the detection of CIN2+ were 92, 54, 33, and 96%, respectively, and very similar to the values observed with RealTime and HC2. The Papilloplex HR-HPV test demonstrated a analytical performance similar to those of the two HPV genotyping tests at the HR-HPV level and the type-specific level. The preliminary data on clinical performance look encouraging, although further longitudinal studies within screening populations are required to confirm these findings. PMID:29237790

  17. Performance of the Primary Mirror Center-of-Curvature Optical Metrology System during Cryogenic Testing of the JWST Pathfinder Telescope

    NASA Technical Reports Server (NTRS)

    Hadaway, James B.; Wells, Conrad; Olczak, Gene; Waldman, Mark; Whitman, Tony; Cosentino, Joseph; Connolly, Mark; Chaney, David; Telfer, Randal

    2016-01-01

    The JWST primary mirror consists of 18 1.5 m hexagonal segments, each with 6-DoF and RoC adjustment. The telescope will be tested at its cryogenic operating temperature at Johnson Space Center. The testing will include center-of-curvature measurements of the PM, using the Center-of-Curvature Optical Assembly (COCOA) and the Absolute Distance Meter Assembly (ADMA). The performance of these metrology systems, including hardware, software, procedures, was assessed during two cryogenic tests at JSC, using the JWST Pathfinder telescope. This paper describes the test setup, the testing performed, and the resulting metrology system performance.

  18. Comparison of Orion Vision Navigation Sensor Performance from STS-134 and the Space Operations Simulation Center

    NASA Technical Reports Server (NTRS)

    Christian, John A.; Patangan, Mogi; Hinkel, Heather; Chevray, Keiko; Brazzel, Jack

    2012-01-01

    The Orion Multi-Purpose Crew Vehicle is a new spacecraft being designed by NASA and Lockheed Martin for future crewed exploration missions. The Vision Navigation Sensor is a Flash LIDAR that will be the primary relative navigation sensor for this vehicle. To obtain a better understanding of this sensor's performance, the Orion relative navigation team has performed both flight tests and ground tests. This paper summarizes and compares the performance results from the STS-134 flight test, called the Sensor Test for Orion RelNav Risk Mitigation (STORRM) Development Test Objective, and the ground tests at the Space Operations Simulation Center.

  19. M-52 spray booth qualification test

    NASA Technical Reports Server (NTRS)

    1990-01-01

    The procedures, performance, and results obtained from the M-52 spray booth qualification test are documented. The test was conducted at Thiokol Corporation, Space Operations, M-52 Inert Parts Preparation facility. The purpose of this testing sequence was to ensure the spray booth would produce flight qualified hardware. The testing sequence was conducted in two series. The first series was conducted under CTP-0142, Revision 1. The second series was conducted in accordance with CTP-0142, Revision 2. The test sequence started with CTP-0142, Revision 1. The series consisted of the contamination removal test and the performance test. The contamination removal test was used to assess the Teflon level in the spray booth. The performance test consisted of painting and Chemloking a forward dome inside the spray booth per flight procedures. During the performance test, two sets of witness panels (case/insulation and steel/epoxy/steel) were prepared and pull tested. The CTP-0142, Revision 2, series of testing consisted of re-testing the steel/epoxy/steel witness panels. The pull tests analysis indicates the results of the tensile tests were comparable to the systems tunnel witness panel database. The exposed panel set and the control panel set average tensile values were above the 1-basis lower limits established on the systems tunnel witness panel database. It is recommended that the M-52 spray booth be qualified for producing flight hardware.

  20. 10 CFR 63.74 - Tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 2 2011-01-01 2011-01-01 false Tests. 63.74 Section 63.74 Energy NUCLEAR REGULATORY..., NEVADA Records, Reports, Tests, and Inspections § 63.74 Tests. (a) DOE shall perform, or permit the Commission to perform, those tests the Commission considers appropriate or necessary for the administration...

  1. 10 CFR 63.74 - Tests.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 2 2012-01-01 2012-01-01 false Tests. 63.74 Section 63.74 Energy NUCLEAR REGULATORY..., NEVADA Records, Reports, Tests, and Inspections § 63.74 Tests. (a) DOE shall perform, or permit the Commission to perform, those tests the Commission considers appropriate or necessary for the administration...

  2. 10 CFR 63.74 - Tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Tests. 63.74 Section 63.74 Energy NUCLEAR REGULATORY..., NEVADA Records, Reports, Tests, and Inspections § 63.74 Tests. (a) DOE shall perform, or permit the Commission to perform, those tests the Commission considers appropriate or necessary for the administration...

  3. 10 CFR 63.74 - Tests.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 2 2014-01-01 2014-01-01 false Tests. 63.74 Section 63.74 Energy NUCLEAR REGULATORY..., NEVADA Records, Reports, Tests, and Inspections § 63.74 Tests. (a) DOE shall perform, or permit the Commission to perform, those tests the Commission considers appropriate or necessary for the administration...

  4. 10 CFR 63.74 - Tests.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 2 2013-01-01 2013-01-01 false Tests. 63.74 Section 63.74 Energy NUCLEAR REGULATORY..., NEVADA Records, Reports, Tests, and Inspections § 63.74 Tests. (a) DOE shall perform, or permit the Commission to perform, those tests the Commission considers appropriate or necessary for the administration...

  5. Front-end Electronics for Unattended Measurement (FEUM). Prototype Test Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Conrad, Ryan C.; Morris, Scott J.; Smith, Leon E.

    2015-09-16

    The IAEA has requested that PNNL perform an initial set of tests on front-end electronics for unattended measurement (FEUM) prototypes. The FEUM prototype test plan details the tests to be performed, the criteria for evaluation, and the procedures used to execute the tests.

  6. Competitive-level differences in Yo-Yo intermittent recovery and twelve minute run test performance in soccer referees.

    PubMed

    Castagna, Carlo; Abt, Grant; D'Ottavio, Stefano

    2005-11-01

    The aim of this study was to examine yo-yo intermittent recovery test (Yo-Yo test) and 12-minute run test (12MRT) performances in experienced soccer referees of different competitive levels. Three groups (n = 14 each) of experienced Italian soccer referees officiating in the first (series AB, top-level), third (series C, medium-level), and fourth (series D, low-level) division, were randomly submitted to the 12MRT and the Yo-Yo test during 2 testing sessions, 48-hours apart. 12MRT performances were 3,000 +/- 112 m; 2,894 +/- 99 m; and 2,896 +/- 171 m for top-level, medium-level and low-level referees, respectively (p > 0.05). In the Yo-Yo test, the top-level, medium-level, and low-level referees covered 1,874 +/- 431 m; 1,360 +/- 172 m; and 1,272 +/- 215 m, respectively. The test performances of top-level referees in the Yo-Yo test was significantly different from those scored by medium-level and low-level referees (p < 0.05). After the Yo-Yo test, blood lactate concentrations (BLC) were higher in the medium-level and low-level referees compared with the top-level referees (p < 0.05). The results of the present study show that the Yo-Yo test and not the 12MRT can discriminate endurance performance in experienced elite level soccer referees. With respect to its discriminative and match performance validity, the Yo-Yo test may be considered a relevant field test to assess endurance preparedness for experienced soccer referees and a useful tool in talent selection.

  7. 40 CFR 60.723 - Performance tests and compliance provisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Industrial Surface Coating: Surface Coating of Plastic Parts for Business Machines § 60.723 Performance tests... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Performance tests and compliance...

  8. 40 CFR 60.723 - Performance tests and compliance provisions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Industrial Surface Coating: Surface Coating of Plastic Parts for Business Machines § 60.723 Performance tests... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Performance tests and compliance...

  9. Laboratory Performance Evaluation Report of SEL 421 Phasor Measurement Unit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Zhenyu; faris, Anthony J.; Martin, Kenneth E.

    2007-12-01

    PNNL and BPA have been in close collaboration on laboratory performance evaluation of phasor measurement units for over ten years. A series of evaluation tests are designed to confirm accuracy and determine measurement performance under a variety of conditions that may be encountered in actual use. Ultimately the testing conducted should provide parameters that can be used to adjust all measurements to a standardized basis. These tests are performed with a standard relay test set using recorded files of precisely generated test signals. The test set provides test signals at a level and in a format suitable for input tomore » a PMU that accurately reproduces the signals in both signal amplitude and timing. Test set outputs are checked to confirm the accuracy of the output signal. The recorded signals include both current and voltage waveforms and a digital timing track used to relate the PMU measured value with the test signal. Test signals include steady-state waveforms to test amplitude, phase, and frequency accuracy, modulated signals to determine measurement and rejection bands, and step tests to determine timing and response accuracy. Additional tests are included as necessary to fully describe the PMU operation. Testing is done with a BPA phasor data concentrator (PDC) which provides communication support and monitors data input for dropouts and data errors.« less

  10. Recall Tests Are Effective to Detect Mild Cognitive Impairment: A Systematic Review and Meta-analysis of 108 Diagnostic Studies.

    PubMed

    Tsoi, Kelvin K F; Chan, Joyce Y C; Hirai, Hoyee W; Wong, Adrian; Mok, Vincent C T; Lam, Linda C W; Kwok, Timothy C Y; Wong, Samuel Y S

    2017-09-01

    Mild cognitive impairment (MCI) is a prevalent symptom associated with the increased risk of dementia. There are many cognitive tests available for detection of MCI, and investigation of the diagnostic performance of the tests is deemed necessary. This study aims to evaluate the diagnostic performance of different cognitive tests used for MCI detection. A list of cognitive tests was identified in previous reviews and from online search engines. Literature searches were performed on each of the cognitive tests in MEDLINE, Embase, and PsycINFO from the earliest available dates of individual databases to December 31, 2016. Google Scholar was used as a supplementary search tool. Studies that were used to assess the diagnostic performance of the cognitive tests were extracted with inclusion and exclusion criteria. Each test's performance was compared with the standard diagnostic criteria. Bivariate random effects models were used to summarize the test performance as a point estimate for sensitivity and specificity, and presented in a summary receiver operating characteristic curve. Reporting quality and risk of bias were evaluated. A total of 108 studies with 23,546 participants were selected to evaluate 9 cognitive tests for MCI detection. Most of the studies used the Mini-Mental State Examination (MMSE) (n = 58) and the Montreal Cognitive Assessment (MoCA) (n = 35). The combined diagnostic performance of the MMSE in MCI detection was 0.71 sensitivity [95% confidence interval (CI): 0.66-0.75] and 0.74 specificity (95% CI: 0.70-0.78), and of the MoCA in MCI detection was 0.83 sensitivity (95% CI: 0.80-0.86) and 0.75 specificity (95% CI: 0.69-0.80). Among the 9 cognitive tests, recall tests showed the best diagnostic performance with 0.89 sensitivity (95% CI: 0.86-0.92) and 0.84 specificity (95% CI, 0.79-0.89). In subgroup analyses, long- or short-delay recall tests have shown better performance than immediate recall tests. Recall tests were shown to be the most effective test in MCI detection, especially for the population with symptoms of memory deterioration. They can be potentially used as the triage screening test for MCI in primary care setting. But when a patient shows cognitive impairments beyond memory deterioration, a more comprehensive test such as the MoCA should be used. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  11. 40 CFR 60.93 - Test methods and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Test methods and procedures. 60.93... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Hot Mix Asphalt Facilities § 60.93 Test methods and procedures. (a) In conducting the performance tests required in § 60.8...

  12. Astronaut Scott Carpenter tests balance mechanism performance

    NASA Technical Reports Server (NTRS)

    1961-01-01

    Astronaut M. Scott Carpenter's balance mechanism performance is tested by his walking on a narrow board in his bare feet. He is performing this test at the School of Aviation Medicine, Pensicola, Florida (04570); Carpenter walks a straight line by putting one foot directly in front of the other to test his balance (04571).

  13. Using Multilevel Analysis to Monitor Test Performance across Administrations. Research Report. ETS RR-14-29

    ERIC Educational Resources Information Center

    Wei, Youhua; Qu, Yanxuan

    2014-01-01

    For a testing program with frequent administrations, it is important to understand and monitor the stability and fluctuation of test performance across administrations. Different methods have been proposed for this purpose. This study explored the potential of using multilevel analysis to understand and monitor examinees' test performance across…

  14. 42 CFR 84.103 - Man tests; performance requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Man tests; performance requirements. 84.103 Section...-Contained Breathing Apparatus § 84.103 Man tests; performance requirements. (a) The apparatus shall satisfy... is 24 ±6 °C. (75 ±10 °F.), the maximum temperature of inspired air recorded during man tests shall...

  15. 42 CFR 84.103 - Man tests; performance requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Man tests; performance requirements. 84.103 Section...-Contained Breathing Apparatus § 84.103 Man tests; performance requirements. (a) The apparatus shall satisfy... is 24 ±6 °C. (75 ±10 °F.), the maximum temperature of inspired air recorded during man tests shall...

  16. 42 CFR 84.103 - Man tests; performance requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Man tests; performance requirements. 84.103 Section...-Contained Breathing Apparatus § 84.103 Man tests; performance requirements. (a) The apparatus shall satisfy... is 24 ±6 °C. (75 ±10 °F.), the maximum temperature of inspired air recorded during man tests shall...

  17. Two-colour chewing gum mixing ability test for evaluating masticatory performance in children with mixed dentition: validity and reliability study.

    PubMed

    Kaya, M S; Güçlü, B; Schimmel, M; Akyüz, S

    2017-11-01

    The unappealing taste of the chewing material and the time-consuming repetitive task in masticatory performance tests using artificial foodstuff may discourage children from performing natural chewing movements. Therefore, the aim was to determine the validity and reliability of a two-colour chewing gum mixing ability test for masticatory performance (MP) assessment in mixed dentition children. Masticatory performance was tested in two groups: systemically healthy fully dentate young adults and children in mixed dentition. Median particle size was assessed using a comminution test, and a two-colour chewing gum mixing ability test was applied for MP analysis. Validity was tested with Pearson correlation, and reliability was tested with intra-class correlation coefficient, Pearson correlation and Bland-Altman plots. Both comminution and two-colour chewing gum mixing ability tests revealed statistically significant MP differences between children (n = 25) and adults (n = 27, both P < 0·01). Pearson correlation between comminution and two-colour chewing gum mixing ability tests was positive and significant (r = 0·418, P = 0·002). Correlations for interobserver reliability and test-retest values were significant (r = 0·990, P = 0·0001 and r = 0·995, P = 0·0001). Although both methods could discriminate MP differences, the comminution test detected these differences generally in a wider range compared to two-colour chewing gum mixing ability test. However, considering the high reliability of the results, the two-colour chewing gum mixing ability test can be used to assess masticatory performance in children, especially at non-clinical settings. © 2017 John Wiley & Sons Ltd.

  18. Impact of Enteroviral Polymerase Chain Reaction Testing on Length of Stay for Infants 60 Days Old or Younger.

    PubMed

    Aronson, Paul L; Lyons, Todd W; Cruz, Andrea T; Freedman, Stephen B; Okada, Pamela J; Fleming, Alesia H; Arms, Joseph L; Thompson, Amy D; Schmidt, Suzanne M; Louie, Jeffrey; Alfonzo, Michael J; Monuteaux, Michael C; Nigrovic, Lise E

    2017-10-01

    To determine the impact of a cerebrospinal fluid enterovirus polymerase chain reaction (PCR) test performance on hospital length of stay (LOS) in a large multicenter cohort of infants undergoing evaluation for central nervous system infection. We performed a planned secondary analysis of a retrospective cohort of hospitalized infants ≤60 days of age who had a cerebrospinal fluid culture obtained at 1 of 18 participating centers (2005-2013). After adjustment for patient age and study year as well as clustering by hospital center, we compared LOS for infants who had an enterovirus PCR test performed vs not performed and among those tested, for infants with a positive vs negative test result. Of 19 953 hospitalized infants, 4444 (22.3%) had an enterovirus PCR test performed and 945 (21.3% of tested infants) had positive test results. Hospital LOS was similar for infants who had an enterovirus PCR test performed compared with infants who did not (incident rate ratio 0.98 hours; 95% CI 0.89-1.06). However, infants PCR positive for enterovirus had a 38% shorter LOS than infants PCR negative for enterovirus (incident rate ratio 0.62 hours; 95% CI 0.57-0.68). No infant with a positive enterovirus PCR test had bacterial meningitis (0%; 95% CI 0-0.4). Although enterovirus PCR testing was not associated with a reduction in LOS, infants with a positive enterovirus PCR test had a one-third shorter LOS compared with infants with a negative enterovirus PCR test. Focused enterovirus PCR test use could increase the impact on LOS for infants undergoing cerebrospinal fluid evaluation. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Pitting and Bending Fatigue Evaluations of a New Case-Carburized Gear Steel

    NASA Technical Reports Server (NTRS)

    Krantz, Timothy; Tufts, Brian

    2007-01-01

    The power density of a gearbox is an important consideration for many applications and is especially important for gearboxes used on aircraft. One approach to improving power density of gearing is to improve the steel properties by design of the alloy. The alloy tested in this work was designed to be case-carburized with surface hardness of Rockwell C66 after hardening. Test gear performance was evaluated using surface fatigue tests and single-tooth bending fatigue tests. The performance of gears made from the new alloy was compared to the performance of gears made from two alloys currently used for aviation gearing. The new alloy exhibited significantly better performance in surface fatigue testing, demonstrating the value of the improved properties in the case layer. However, the alloy exhibited lesser performance in single-tooth bending fatigue testing. The fracture toughness of the tested gears was insufficient for use in aircraft applications as judged by the behavior exhibited during the single tooth bending tests. This study quantified the performance of the new alloy and has provided guidance for the design and development of next generation gear steels.

  20. Test of Hydrogen-Oxygen PEM Fuel Cell Stack at NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Bents, David J.; Scullin, Vincent J.; Chang, Bei-Jiann; Johnson, Donald W.; Garcia, Christopher P.; Jakupca, Ian J.

    2003-01-01

    This paper describes performance characterization tests of a 64 cell hydrogen oxygen PEM fuel cell stack at NASA Glenn Research Center in February 2003. The tests were part of NASA's ongoing effort to develop a regenerative fuel cell for aerospace energy storage applications. The purpose of the tests was to verify capability of this stack to operate within a regenerative fuel cell, and to compare performance with earlier test results recorded by the stack developer. Test results obtained include polarization performance of the stack at 50 and 100 psig system pressure, and a steady state endurance run at 100 psig. A maximum power output of 4.8 kWe was observed during polarization runs, and the stack sustained a steady power output of 4.0 kWe during the endurance run. The performance data obtained from these tests compare reasonably close to the stack developer's results although some additional spread between best to worst performing cell voltages was observed. Throughout the tests, the stack demonstrated the consistent performance and repeatable behavior required for regenerative fuel cell operation.

  1. Advanced Stirling Convertor (ASC-E2) Performance Testing at NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Oriti, Salvatore; Wilson, Scott

    2011-01-01

    The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has been supporting development of the Advanced Stirling Radioisotope Generator (ASRG) since 2006. A key element of the ASRG Project is providing life, reliability, and performance testing of the Advanced Stirling Convertor (ASC). For this purpose, four pairs of ASCs capable of operating to 850 C and designated with the model number ASC-E2, were delivered by Sunpower of Athens, OH, to GRC in 2010. The ASC-E2s underwent a series of tests that included workmanship vibration testing, performance mapping, and extended operation. Workmanship vibration testing was performed following fabrication of each convertor to verify proper hardware build. Performance mapping consisted of operating each convertor at various conditions representing the range expected during a mission. Included were conditions representing beginning-of-mission (BOM), end-of-mission (EOM), and fueling. This same series of tests was performed by Sunpower prior to ASC-E2 delivery. The data generated during the GRC test were compared to performance before delivery. Extended operation consisted of a 500-hour period of operation with conditions maintained at the BOM point. This was performed to demonstrate steady convertor performance following performance mapping. Following this initial 500-hour period, the ASC-E2s will continue extended operation, controller development and special durability testing, during which the goal is to accumulate tens of thousands of hours of operation. Data collected during extended operation will support reliability analysis. Performance data from these tests is summarized in this paper.

  2. Advanced Stirling Convertor (ASC-E2) Performance Testing at NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Oriti, Salvatore; Wilson, Scott

    2011-01-01

    The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has been supporting development of the Advanced Stirling Radioisotope Generator (ASRG) since 2006. A key element of the ASRG Project is providing life, reliability, and performance testing of the Advanced Stirling Convertor (ASC). For this purpose, four pairs of ASCs capable of operating to 850 C and designated with the model number ASC-E2, were delivered by Sunpower of Athens, Ohio, to GRC in 2010. The ASC-E2s underwent a series of tests that included workmanship vibration testing, performance mapping, and extended operation. Workmanship vibration testing was performed following fabrication of each convertor to verify proper hardware build. Performance mapping consisted of operating each convertor at various conditions representing the range expected during a mission. Included were conditions representing beginning-of-mission (BOM), end-of-mission (EOM), and fueling. This same series of tests was performed by Sunpower prior to ASC-E2 delivery. The data generated during the GRC test were compared to performance before delivery. Extended operation consisted of a 500-hr period of operation with conditions maintained at the BOM point. This was performed to demonstrate steady convertor performance following performance mapping. Following this initial 500-hr period, the ASC-E2s will continue extended operation, controller development and special durability testing, during which the goal is to accumulate tens of thousands of hours of operation. Data collected during extended operation will support reliability analysis. Performance data from these tests is summarized in this paper.

  3. Field tests of 2- and 40-tube condensers at the East Mesa Geothermal Test Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murphy, R.W.; Domingo, N.

    1982-05-01

    Two water-cooled isobutane condensers, one with 2 tubes and one with 40 tubes, were subjected to field tests at the East Mesa Geothermal Test Site to assess relative heat transfer performance in both surface evaporator and direct-contact evaporator modes. The five groups of tests established that field performance was below earlier laboratory-determined levels and that direct-contact evaporator mode performance was poorer than that for the surface evaporator mode. In all test situations, fluted condenser tubes performed better than smooth condenser tubes. Cooling water quality had no significant effect on performance, but brine preflash in the direct-contact mode did promote somemore » relative performance improvement. Important implications of these results for binary geothermal power plants are that (1) working-fluid-side impurities can significantly degrade heat transfer performance of the power plant condensers and (2) provisions for minimizing such impurities may be required.« less

  4. Assessing fitness-for-duty and predicting performance with cognitive neurophysiological measures

    NASA Astrophysics Data System (ADS)

    Smith, Michael E.; Gevins, Alan

    2005-05-01

    Progress is described in developing a novel test of neurocognitive status for fitness-for-duty testing. The Sustained Attention & Memory (SAM) test combines neurophysiologic (EEG) measures of brain activation with performance measures during a psychometric test of sustained attention and working memory, and then gauges changes in neurocognitive status relative to an individual"s normative baseline. In studies of the effects of common psychoactive substances that can affect job performance, including sedating antihistamines, caffeine, alcohol, marijuana, and prescription medications, test sensitivity was greater for the combined neurophysiological and performance measures than for task performance measures by themselves. The neurocognitive effects of overnight sleep deprivation were quite evident, and such effects predicted subsequent performance impairment on a flight simulator task. Sensitivity to diurnal circadian variations was also demonstrated. With further refinement and independent validation, the SAM Test may prove useful for assessing readiness-to-perform in high-asset personnel working in demanding, high risk situations.

  5. "Chair Stand Test" as Simple Tool for Sarcopenia Screening in Elderly Women.

    PubMed

    Pinheiro, P A; Carneiro, J A O; Coqueiro, R S; Pereira, R; Fernandes, M H

    2016-01-01

    To investigate the association between sarcopenia and "chair stand test" performance, and evaluate this test as a screening tool for sarcopenia in community-dwelling elderly women. Cross-sectional Survey. 173 female individuals, aged ≥ 60 years and living in the urban area of the municipality of Lafaiete Coutinho, Bahia's inland, Brazil. The association between sarcopenia (defined by muscle mass, strength and/or performance loss) and performance in the "chair stand test" was tested by binary logistic regression technique. The ROC curve parameters were used to evaluate the diagnostic power of the test in sarcopenia screening. The significance level was set at 5 %. The model showed that the time spent for the "chair stand test" was positively associated (OR = 1.08; 95% CI = 1.01 - 1.16, p = 0.024) to sarcopenia, indicating that, for each 1 second increment in the test performance, the sarcopenia's probability increased by 8% in elderly women. The cut-off point that showed the best balance between sensitivity and specificity was 13 seconds. The performance of "chair stand test" showed predictive ability for sarcopenia, being an effective and simple screening tool for sarcopenia in elderly women. This test could be used for screening sarcopenic elderly women, allowing early interventions.

  6. Evaluation of 2 cognitive abilities tests in a dual-task environment

    NASA Technical Reports Server (NTRS)

    Vidulich, M. A.; Tsang, P. S.

    1986-01-01

    Most real world operators are required to perform multiple tasks simultaneously. In some cases, such as flying a high performance aircraft or trouble shooting a failing nuclear power plant, the operator's ability to time share or process in parallel" can be driven to extremes. This has created interest in selection tests of cognitive abilities. Two tests that have been suggested are the Dichotic Listening Task and the Cognitive Failures Questionnaire. Correlations between these test results and time sharing performance were obtained and the validity of these tests were examined. The primary task was a tracking task with dynamically varying bandwidth. This was performed either alone or concurrently with either another tracking task or a spatial transformation task. The results were: (1) An unexpected negative correlation was detected between the two tests; (2) The lack of correlation between either test and task performance made the predictive utility of the tests scores appear questionable; (3) Pilots made more errors on the Dichotic Listening Task than college students.

  7. Physiological Factors Contributing to Postflight Changes in Functional Performance

    NASA Technical Reports Server (NTRS)

    Bloomberg, J. J.; Feedback, D. L.; Feiverson, A. H.; Lee, S. M. C.; Mulavara, A. P.; Peters, B. T.; Platts, S. H.; Reschke, M. F.; Ryder, J.; Spiering, B. A.; hide

    2009-01-01

    Astronauts experience alterations in multiple physiological systems due to exposure to the microgravity conditions of space flight. These physiological changes include sensorimotor disturbances, cardiovascular deconditioning and loss of muscle mass and strength. These changes might affect the ability of crewmembers to perform critical mission tasks immediately after landing on lunar and Martian surfaces. To date, changes in functional performance have not been systematically studied or correlated with physiological changes. To understand how changes in physiological function impact functional performance an interdisciplinary pre/postflight testing regimen (Functional Task Test, FTT) has been developed that systematically evaluates both astronaut postflight functional performance and related physiological changes. The overall objectives of the FTT are to: Develop a set of functional tasks that represent critical mission tasks for Constellation. Determine the ability to perform these tasks after flight. Identify the key physiological factors that contribute to functional decrements. Use this information to develop targeted countermeasures. The functional test battery was designed to address high priority tasks identified by the Constellation program as critical for mission success. The set of functional tests making up the FTT include the: 1) Seat Egress and Walk Test, 2) Ladder Climb Test, 3) Recovery from Fall/Stand Test, 4) Rock Translation Test, 5) Jump Down Test, 6) Torque Generation Test, and 7) Construction Activity Board Test. Corresponding physiological measures include assessments of postural and gait control, dynamic visual acuity, fine motor control, plasma volume, orthostatic intolerance, upper and lower body muscle strength, power, fatigue, control and neuromuscular drive. Crewmembers will perform both functional and physiological tests before and after short (Shuttle) and long-duration (ISS) space flight. Data will be collected on R+0 (Shuttle only), R+1, R+6 and R+30. Using a multivariate regression model we will identify which physiological systems contribute the most to impaired performance on each functional test. This will allow us to identify the physiological systems that play the largest role in decrement in functional performance. Using this information we can then design and implement countermeasures that specifically target the physiological systems most responsible for the altered functional performance associated with space flight.

  8. Temporary Thermocouple Attachment for Thermal/Vacuum Testing at Non-Extreme Temperatures - Test Results

    NASA Technical Reports Server (NTRS)

    Wright, Sarah E.; Ungar, Eugene K.

    2017-01-01

    Post-test examination and data analysis that followed a two week long vacuum test showed that numerous self-stick thermocouples became detached from the test article. The thermocouples were reattached with thermally conductive epoxy and the test was repeated to obtain the required data. Because the thermocouple detachment resulted in significant expense and rework, it was decided to investigate the temporary attachment methods used around NASA and to perform a test to assess their efficacy. The present work describes the testing that was performed in early and mid-2017. The test article and the temporary thermocouple attachment methods tested are described. During the first test, fully half of the thermocouples detached - although the detachment showed subtly in the data for some. The second test was performed to confirm the data from the first test and to investigate the effect of test article and thermocouple grounding. The results of the testing over temperatures ranging from -150 to 200degF are detailed and preliminary recommendations are made for temporary thermocouple attachment methods.

  9. Computerized Tests of Team Performance and Crew Coordination Suitable for Military/Aviation Settings.

    PubMed

    Lawson, Ben D; Britt, Thomas W; Kelley, Amanda M; Athy, Jeremy R; Legan, Shauna M

    2017-08-01

    The coordination of team effort on shared tasks is an area of inquiry. A number of tests of team performance in challenging environments have been developed without comparison or standardization. This article provides a systematic review of the most accessible and usable low-to-medium fidelity computerized tests of team performance and determines which are most applicable to military- and aviation-relevant research, such as studies of group command, control, communication, and crew coordination. A search was conducted to identify computerized measures of team performance. In addition to extensive literature searches (DTIC, Psychinfo, PubMed), the authors reached out to team performance researchers at conferences and through electronic communication. Identified were 57 potential tests according to 6 specific selection criteria (e.g., the requirement for automated collection of team performance and coordination processes, the use of military-relevant scenarios). The following seven tests (listed alphabetically) were considered most suitable for military needs: Agent Enabled Decision Group Environment (AEDGE), C3Conflict, the C3 (Command, Control, & Communications) Interactive Task for Identifying Emerging Situations (NeoCITIES), Distributed Dynamic Decision Making (DDD), Duo Wondrous Original Method Basic Awareness/Airmanship Test (DuoWOMBAT), the Leader Development Simulator (LDS), and the Planning Task for Teams (PLATT). Strengths and weaknesses of these tests are described and recommendations offered to help researchers identify the test most suitable for their particular needs. Adoption of a few standard computerized test batteries to study team performance would facilitate the evaluation of interventions intended to enhance group performance in multiple challenging military and aerospace operational environments.Lawson BD, Britt TW, Kelley AM, Athy JR, Legan SM. Computerized tests of team performance and crew coordination suitable for military/aviation settings. Aerosp Med Hum Perform. 2017; 88(8):722-729.

  10. Yo-Yo IR1 vs. incremental continuous running test for prediction of 3000-m performance.

    PubMed

    Schmitz, Boris; Klose, Andreas; Schelleckes, Katrin; Jekat, Charlotte M; Krüger, Michael; Brand, Stefan-Martin

    2017-11-01

    This study aimed to compare physiological responses during the Yo-Yo intermittent recovery level 1 (Yo-Yo IR1) Test and an incremental continuous running field Test (ICRT) and to analyze their predictive value on 3000-m running performance. Forty moderately trained individuals (18 females) performed the ICRT and Yo-Yo IR1 Test to exhaustion. The ICRT was performed as graded running test with an increase of 2.0 km·h-1 after each 3 min interval for lactate diagnostic. In both tests, blood lactate levels were determined after the test and at 2 and 5 min of recovery. Heart rate (HR) was recorded to monitor differences in HR slopes and HR recovery. Comparison revealed a correlation between ICRT and Yo-Yo IR1 Test performance (R2=0.83, P<0.001), while significant differences in HRmax existed (Yo-Yo IR1, 189±10 bpm; ICRT, 195±16 bpm; P<0.005; ES=0.5). Maximum lactate levels were also different between test (Yo-Yo IR1, 10.1±2.1 mmol∙L-1; ICRT, 11.7±2.4 mmol∙L-1; P<0.01; ES=0.7). Significant inverse correlations were found between the Yo-Yo IR1 Test performance and 3000 m running time (R2=0.77, P<0.0001) as well as the ICRT and 3000 m time (R2=0.90, P<0.0001). Our data suggest that ICRT and Yo-Yo IR1 test are useful field test methods for the prediction of competitive running performances such as 3000-m runs but maximum HR and blood lactate values differ significantly. The ICRT may have higher predictive power for middle- to long- distance running performance such as 3000-m runs offering a reliable test for coaches in the recruitment of athletes or supervision of training concepts.

  11. The Semiautomated Test System: A Tool for Standardized Performance Testing.

    ERIC Educational Resources Information Center

    Ramsey, H. Rudy

    For performance tests to be truly standardized, they must be administered in a way that will minimize variation due to operator intervention and errors. Through such technological developments as low-cost digital computers and digital logic modules, automatic test administration without restriction of test content has become possible. A…

  12. Does Test Item Performance Increase with Test-to-Standards Alignment?

    ERIC Educational Resources Information Center

    Traynor, Anne

    2017-01-01

    Variation in test performance among examinees from different regions or national jurisdictions is often partially attributed to differences in the degree of content correspondence between local school or training program curricula, and the test of interest. This posited relationship between test-curriculum correspondence, or "alignment,"…

  13. 10 CFR 30.53 - Tests.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Tests. 30.53 Section 30.53 Energy NUCLEAR REGULATORY..., Tests, and Reports § 30.53 Tests. Each licensee shall perform, or permit the Commission to perform, such tests as the Commission deems appropriate or necessary for the administration of the regulations in this...

  14. 10 CFR 30.53 - Tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Tests. 30.53 Section 30.53 Energy NUCLEAR REGULATORY..., Tests, and Reports § 30.53 Tests. Each licensee shall perform, or permit the Commission to perform, such tests as the Commission deems appropriate or necessary for the administration of the regulations in this...

  15. 10 CFR 60.74 - Tests.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 2 2013-01-01 2013-01-01 false Tests. 60.74 Section 60.74 Energy NUCLEAR REGULATORY..., Tests, and Inspections § 60.74 Tests. (a) DOE shall perform, or permit the Commission to perform, such tests as the Commission deems appropriate or necessary for the administration of the regulations in this...

  16. 10 CFR 30.53 - Tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Tests. 30.53 Section 30.53 Energy NUCLEAR REGULATORY..., Tests, and Reports § 30.53 Tests. Each licensee shall perform, or permit the Commission to perform, such tests as the Commission deems appropriate or necessary for the administration of the regulations in this...

  17. 10 CFR 60.74 - Tests.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 2 2014-01-01 2014-01-01 false Tests. 60.74 Section 60.74 Energy NUCLEAR REGULATORY..., Tests, and Inspections § 60.74 Tests. (a) DOE shall perform, or permit the Commission to perform, such tests as the Commission deems appropriate or necessary for the administration of the regulations in this...

  18. 10 CFR 60.74 - Tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Tests. 60.74 Section 60.74 Energy NUCLEAR REGULATORY..., Tests, and Inspections § 60.74 Tests. (a) DOE shall perform, or permit the Commission to perform, such tests as the Commission deems appropriate or necessary for the administration of the regulations in this...

  19. 10 CFR 60.74 - Tests.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 2 2012-01-01 2012-01-01 false Tests. 60.74 Section 60.74 Energy NUCLEAR REGULATORY..., Tests, and Inspections § 60.74 Tests. (a) DOE shall perform, or permit the Commission to perform, such tests as the Commission deems appropriate or necessary for the administration of the regulations in this...

  20. 10 CFR 30.53 - Tests.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Tests. 30.53 Section 30.53 Energy NUCLEAR REGULATORY..., Tests, and Reports § 30.53 Tests. Each licensee shall perform, or permit the Commission to perform, such tests as the Commission deems appropriate or necessary for the administration of the regulations in this...

  1. 10 CFR 30.53 - Tests.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Tests. 30.53 Section 30.53 Energy NUCLEAR REGULATORY..., Tests, and Reports § 30.53 Tests. Each licensee shall perform, or permit the Commission to perform, such tests as the Commission deems appropriate or necessary for the administration of the regulations in this...

  2. 10 CFR 60.74 - Tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 2 2011-01-01 2011-01-01 false Tests. 60.74 Section 60.74 Energy NUCLEAR REGULATORY..., Tests, and Inspections § 60.74 Tests. (a) DOE shall perform, or permit the Commission to perform, such tests as the Commission deems appropriate or necessary for the administration of the regulations in this...

  3. 15 CFR 995.27 - Format validation software testing.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 15 Commerce and Foreign Trade 3 2013-01-01 2013-01-01 false Format validation software testing... of NOAA ENC Products § 995.27 Format validation software testing. Tests shall be performed verifying, as far as reasonable and practicable, that CEVAD's data testing software performs the checks, as...

  4. 15 CFR 995.27 - Format validation software testing.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 15 Commerce and Foreign Trade 3 2014-01-01 2014-01-01 false Format validation software testing... of NOAA ENC Products § 995.27 Format validation software testing. Tests shall be performed verifying, as far as reasonable and practicable, that CEVAD's data testing software performs the checks, as...

  5. 15 CFR 995.27 - Format validation software testing.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 15 Commerce and Foreign Trade 3 2012-01-01 2012-01-01 false Format validation software testing... of NOAA ENC Products § 995.27 Format validation software testing. Tests shall be performed verifying, as far as reasonable and practicable, that CEVAD's data testing software performs the checks, as...

  6. 15 CFR 995.27 - Format validation software testing.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 3 2011-01-01 2011-01-01 false Format validation software testing... of NOAA ENC Products § 995.27 Format validation software testing. Tests shall be performed verifying, as far as reasonable and practicable, that CEVAD's data testing software performs the checks, as...

  7. 40 CFR 60.58b - Compliance and performance testing.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... monitored and record the output of the system and shall comply with the test procedures and test methods....1.1 (relative accuracy test audit) shall apply to the monitor. (6) If carbon dioxide is selected for... established during the initial performance test according to the procedures and methods specified in...

  8. 40 CFR 60.58b - Compliance and performance testing.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... monitored and record the output of the system and shall comply with the test procedures and test methods....1.1 (relative accuracy test audit) shall apply to the monitor. (6) If carbon dioxide is selected for... established during the initial performance test according to the procedures and methods specified in...

  9. 40 CFR 60.58b - Compliance and performance testing.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... monitored and record the output of the system and shall comply with the test procedures and test methods....1.1 (relative accuracy test audit) shall apply to the monitor. (6) If carbon dioxide is selected for... established during the initial performance test according to the procedures and methods specified in...

  10. Kapton wire arc track testing: Per test procedure KWATT BB01

    NASA Technical Reports Server (NTRS)

    1990-01-01

    The results are presented of Kapton wire arc tracking tests performed at NASA-Johnson in 1990 using test procedure KWATT BB01. The tests were performed to gather data for use in assessing the safety of the Space Shuttle Orbiter wiring which is predominantly Kapton insulated.

  11. Performance, Cognition, and Physiological Responding in Test Anxiety.

    ERIC Educational Resources Information Center

    Holroyd, Kenneth A.; And Others

    1978-01-01

    This research was designed to clarify the role of autonomic response and evaluative self-awareness in test anxiety. Autonomic, self-report, and performance measures of anxiety were collected from both test-anxious and non-test-anxious individuals in an analogue testing situation under three experimental conditions. Results support cognitive…

  12. Tests of measurement invariance failed to support the application of the "then-test".

    PubMed

    Nolte, Sandra; Elsworth, Gerald R; Sinclair, Andrew J; Osborne, Richard H

    2009-11-01

    The use of then-test (retrospective pre-test) scores has frequently been proposed as a solution to potential confounding of change scores because of response shift, as it is assumed that then-test and post-test responses are provided from the same perspective. However, this assumption has not been formally tested using robust quantitative methods. The aim of this study was to compare the psychometric performance of then-test/post-test with traditional pre-test/post-test data and assessing whether the resulting data structures support the application of the then-test for evaluations of chronic disease self-management interventions. Pre-test, post-test, and then-test data were collected from 314 participants of self-management courses using the Health Education Impact Questionnaire (heiQ). The derived change scores (pre-test/post-test; then-test/post-test) were examined for their psychometric performance using tests of measurement invariance. Few questionnaire items were noninvariant across pre-test/post-test, with four items identified and requiring removal to enable an unbiased comparison of factor means. In contrast, 12 items were identified and required removal in then-test/post-test data to avoid biased change score estimates. Traditional pre-test/post-test data appear to be robust with little indication of response shift. In contrast, the weaker psychometric performance of then-test/post-test data suggests psychometric flaws that may be the result of implicit theory of change, social desirability, and recall bias.

  13. Impact of HPV testing, HPV vaccine development, and changing screening frequency on national Pap test volume: projections from the National Health Interview Survey (NHIS).

    PubMed

    Eltoum, Isam A; Roberson, Janie

    2007-02-25

    The frequently cited number of 50 million annual Papanicolaou cervical screening (Pap) tests performed in the US was based on the National Health Interview Survey (NHIS) of the 1980s. Since then, monumental changes have occurred. More change will soon follow when primary human papilloma virus (HPV) testing and/or HPV vaccine delivery are fully accepted and implemented. The objectives of this study were 1) to estimate the total annual Pap tests performed in the US based on recent NHIS surveys, and 2) to estimate the potential change in the total annual Pap volume produced by changing demographics, reduced screening frequency, HPV testing, and the HPV vaccine. In the NHIS 2000 and NHIS 2005, women were asked to report the frequency of their Pap tests for the 6 years prior to the interview and to report whether they had abnormal findings. The authors analyzed the survey respondents answers to these questions by using SAS Survey Procedures (SAS Institute, NC). The results were stratified by age, and the total national volume was then extrapolated from a similarly stratified 2000 US census. The projected increase of total Pap tests for the next 25 years was determined by using the projected census data. Potential reductions of Pap tests performed secondarily to HPV testing of women >30 years old and of HPV vaccination were also determined. Based on NHIS 2000 and NHIS 2005, 66 million (95% CI, 65-68) and 65 million (95% CI, 64-67) Pap tests were performed in the US, respectively. Had HPV testing been performed in women older than 30 years who had both negative HPV and negative 3-year Pap tests, then 30% (95% CI, 29-32%) of Pap tests would not have been performed. If both HPV testing and vaccination are performed, the total number of Pap tests performed annually is predicted to be reduced by 43% (95% CI, 35-38%). Therefore, despite an expected increase in the population of women eligible for Pap tests, the total number will likely decrease substantially in the future. This, in turn, will decrease the demand for a traditionally trained cytotechnology workforce. (c) 2007 American Cancer Society.

  14. Testing of small and large sign support systems FOIL test numbers : 92F009 and 92F010

    DOT National Transportation Integrated Search

    1994-07-01

    This test report contains the results of two crash tests performed at the Federal Outdoor Impact Laboratory (FOIL) in McLean, Virginia. The/tests were performed on a small sign support system at 20 rni/h (8.9 m/s), test 92F009 and 60 mi/h (26.8 m/s),...

  15. CRBR pump water test experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cook, M.E.; Huber, K.A.

    1983-01-01

    The hydraulic design features and water testing of the hydraulic scale model and prototype pump of the sodium pumps used in the primary and intermediate sodium loops of the Clinch River Breeder Reactor Plant (CRBRP) are described. The Hydraulic Scale Model tests are performed and the results of these tests are discussed. The Prototype Pump tests are performed and the results of these tests are discussed.

  16. Testing of small and large sign support systems FOIL test numbers : 92F024 and 92F025

    DOT National Transportation Integrated Search

    1994-07-01

    This test report contains the results of two crash tests performed at the Federal Outdoor Impact Laboratory (FOIL) in McLean, Virginia. The tests were performed on a small sign support system at 20 mi/h (8.9 m/s), test 92F024, and 60 mi/h (26.8 m/s),...

  17. Comparing the performance plateau in adult cochlear implant patients using HINT and AzBio.

    PubMed

    Massa, Sean T; Ruckenstein, Michael J

    2014-04-01

    This study aims to characterize the performance plateau in adult cochlear implant recipients after the initial postimplantation increase by using word recognition testing and an explicit definition of performance plateau. Retrospective review. Urban, tertiary referral center. One hundred twenty-five patients with 138 devices tested with AzBio were matched to 130 patients with 138 devices tested with HINT based on performed on CNC monosyllable tests. Patient's performance was measured overtime using AzBio and HINT tests to determine when and at what score their performance reached a plateau. Time from implantation to reach a performance plateau and plateau score with each test. Thirty-four devices reached a HINT plateau and 30 devices reached an AzBio plateau. Patients reached plateaus at similar times postoperatively using HINT and AzBio, 18.8 and 16.5 weeks, respectively (p = 0.476). Five patients tested with HINT plateaued at scores of 99% to 100%, whereas no patients plateaued above 92% with AzBio. Patients reached a plateau in performance at similar median times using AzBio and HINT, despite the ceiling effect of HINT in some patients. Most patients who reach a plateau did so within 4 months, but exactly when and if a patient's performance plateaus varies significantly among individuals. Further study is required to determine which test best reflects when a patient reaches his or her maximal performance in natural listening conditions.

  18. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Engineering Test Report: AMSU-A1 EOS Instrument, (S/N 202) Qualification Level Vibration Tests of August/September 1998, (S/O 565632, OC-417) Plus Addendum A

    NASA Technical Reports Server (NTRS)

    Heffer, R.

    1998-01-01

    The purpose of this report is to present a qualification level vibration testing performed on the S/N 202, EOS AMSU-A1 Instrument was vibration tested to qualification levels per the Ref. 1 shop order. The instrument withstood the 8 g sine sweep test, the 7.5 Grms random vibration test, and the 18.75 g sine burst test in each of the three orthogonal axes. Some loss of transmissibility, however, is seen in the lower reflector after Z-axis random vibration. The test sequence was not without incidence. Failure of Channel 7 in the Limited Performance Test (LPT) performed after completion of the 1 st (X-axis) axis vibration sequence, required replacement of the DRO and subsequent re-testing of the instrument. The post-vibration comprehensive performance test (CPT) was successfully run after completion of the three axes of vibration with the replacement component installed in the instrument. Passing the CPT signified the successful completion of the S/N 202 A1 qualification vibration testing.

  19. Performance testing for superpave and structural validation.

    DOT National Transportation Integrated Search

    2012-11-01

    The primary objective of this full-scale accelerated pavement testing was to evaluate the performance of unmodified : and polymer modified asphalt binders and to recommend improved specification tests over existing SUperior : PERforming Asphalt PAVEm...

  20. 40 CFR 60.154 - Test methods and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Sewage Treatment Plants § 60.154 Test methods and procedures. (a) In conducting the performance tests required in § 60.8...

  1. Propfan test assessment testbed aircraft stability and control/performance 1/9-scale wind tunnel tests

    NASA Technical Reports Server (NTRS)

    Little, B. H., Jr.; Tomlin, K. H.; Aljabri, A. S.; Mason, C. A.

    1988-01-01

    One-ninth scale wind tunnel model tests of the Propfan Test Assessment (PTA) aircraft were performed in three different NASA facilities. Wing and propfan nacelle static pressures, model forces and moments, and flow field at the propfan plane were measured in these tests. Tests started in June 1985 and were completed in January 1987. These data were needed to assure PTA safety of flight, predict PTA performance, and validate analytical codes that will be used to predict flow fields in which the propfan will operate.

  2. Results of a First Generation Propellant Energy Source Module Testing: Non-Nuclear Testing of Fission System

    NASA Technical Reports Server (NTRS)

    VanDyke, Melissa; Godfroy, Tom; Houts, Mike; Dickens, Ricky; Dobson, Chris; Pederson, Kevin; Reid, Bob

    1999-01-01

    The use of resistance heaters to simulate heat from fission allows extensive development of fission systems to be performed in non-nuclear test facilities, saving time and money. Resistance heated tests on the Module Unfueled Thermal- hydraulic Test (MUTT) article has been performed at the Marshall Space Flight Center. This paper discusses the results of these experiments to date, and describes the additional testing that will be performed. Recommendations related to the design of testable space fission power and propulsion systems are made.

  3. Results of a first generation least expensive approach to fission module tests: Non-nuclear testing of a fission system

    NASA Astrophysics Data System (ADS)

    van Dyke, Melissa; Godfroy, Tom; Houts, Mike; Dickens, Ricky; Dobson, Chris; Pederson, Kevin; Reid, Bob; Sena, J. Tom

    2000-01-01

    The use of resistance heaters to simulate heat from fission allows extensive development of fission systems to be performed in non-nuclear test facilities, saving time and money. Resistance heated tests on the Module Unfueled Thermal-hydraulic Test (MUTT) article has been performed at the Marshall Space Flight Center. This paper discusses the results of these experiments to date, and describes the additional testing that will be performed. Recommendations related to the design of testable space fission power and propulsion systems are made. .

  4. Vacuum decay container/closure integrity testing technology. Part 1. ASTM F2338-09 precision and bias studies.

    PubMed

    Wolf, Heinz; Stauffer, Tony; Chen, Shu-Chen Y; Lee, Yoojin; Forster, Ronald; Ludzinski, Miron; Kamat, Madhav; Godorov, Phillip; Guazzo, Dana Morton

    2009-01-01

    ASTM F2338-09 Standard Test Method for Nondestructive Detection of Leaks in Packages by Vacuum Decay Method is applicable for leak-testing rigid and semi-rigid non-lidded trays; trays or cups sealed with porous barrier lidding materials; rigid, nonporous packages; and flexible, nonporous packages. Part 1 of this series describes the precision and bias studies performed in 2008 to expand this method's scope to include rigid, nonporous packages completely or partially filled with liquid. Round robin tests using three VeriPac 325/LV vacuum decay leak testers (Packaging Technologies & Inspection, LLC, Tuckahoe, NY) were performed at three test sites. Test packages were 1-mL glass syringes. Positive controls had laser-drilled holes in the barrel ranging from about 5 to 15 microm in nominal diameter. Two different leak tests methods were performed at each site: a "gas leak test" performed at 250 mbar (absolute) and a "liquid leak test" performed at about 1 mbar (absolute). The gas leak test was used to test empty, air-filled syringes. All defects with holes > or = 5.0 microm and all no-defect controls were correctly identified. The only false negative result was attributed to a single syringe with a < 5.0-microm hole. Tests performed using a calibrated air leak supported a 0.10-cm3 x min(-1) (ccm) sensitivity limit (99/99 lower tolerance limit). The liquid leak test was used to test both empty, air-filled syringes and water-filled syringes. Test results were 100% accurate for all empty and water-filled syringes, both without holes and with holes (5, 10, and 15 microm). Tests performed using calibrated air flow leaks of 0, 0.05, and 0.10 ccm were also 100% accurate; data supported a 0.10-ccm sensitivity limit (99/99 lower tolerance limit). Quantitative differential pressure results strongly correlated to hole size using either liquid or gas vacuum decay leak tests. The higher vacuum liquid leak test gave noticeably higher pressure readings when water was present in the defect. Both the ASTM F2338-09 test method and the precision and bias study report are available by contacting ASTM International in West Conshohocken, PA, USA (www.astm.org).

  5. Development and Results of a First Generation Least Expensive Approach to Fission: Module Tests and Results

    NASA Technical Reports Server (NTRS)

    Houts, Mike; Godfroy, Tom; Pederson, Kevin; Sena, J. Tom; VanDyke, Melissa; Dickens, Ricky; Reid, Bob J.; Martin, Jim

    2000-01-01

    The use of resistance heaters to simulate heat from fission allows extensive development of fission systems to be performed in non-nuclear test facilities, saving time and money. Resistance heated tests on the Module Unfueled Thermal-hydraulic Test (MUTT) article has been performed at the Marshall Space Flight Center. This paper discusses the results of these experiments and identifies future tests to be performed.

  6. Wind tunnel performance results of an aeroelastically scaled 2/9 model of the PTA flight test prop-fan

    NASA Technical Reports Server (NTRS)

    Stefko, George L.; Rose, Gayle E.; Podboy, Gary G.

    1987-01-01

    High speed wind tunnel aerodynamic performance tests of the SR-7A advanced prop-fan have been completed in support of the Prop-Fan Test Assessment (PTA) flight test program. The test showed that the SR-7A model performed aerodynamically very well. At the cruise design condition, the SR-7A prop fan had a high measured net efficiency of 79.3 percent.

  7. Impact of Educational Level on Performance on Auditory Processing Tests.

    PubMed

    Murphy, Cristina F B; Rabelo, Camila M; Silagi, Marcela L; Mansur, Letícia L; Schochat, Eliane

    2016-01-01

    Research has demonstrated that a higher level of education is associated with better performance on cognitive tests among middle-aged and elderly people. However, the effects of education on auditory processing skills have not yet been evaluated. Previous demonstrations of sensory-cognitive interactions in the aging process indicate the potential importance of this topic. Therefore, the primary purpose of this study was to investigate the performance of middle-aged and elderly people with different levels of formal education on auditory processing tests. A total of 177 adults with no evidence of cognitive, psychological or neurological conditions took part in the research. The participants completed a series of auditory assessments, including dichotic digit, frequency pattern and speech-in-noise tests. A working memory test was also performed to investigate the extent to which auditory processing and cognitive performance were associated. The results demonstrated positive but weak correlations between years of schooling and performance on all of the tests applied. The factor "years of schooling" was also one of the best predictors of frequency pattern and speech-in-noise test performance. Additionally, performance on the working memory, frequency pattern and dichotic digit tests was also correlated, suggesting that the influence of educational level on auditory processing performance might be associated with the cognitive demand of the auditory processing tests rather than auditory sensory aspects itself. Longitudinal research is required to investigate the causal relationship between educational level and auditory processing skills.

  8. DECIDE: a software for computer-assisted evaluation of diagnostic test performance.

    PubMed

    Chiecchio, A; Bo, A; Manzone, P; Giglioli, F

    1993-05-01

    The evaluation of the performance of clinical tests is a complex problem involving different steps and many statistical tools, not always structured in an organic and rational system. This paper presents a software which provides an organic system of statistical tools helping evaluation of clinical test performance. The program allows (a) the building and the organization of a working database, (b) the selection of the minimal set of tests with the maximum information content, (c) the search of the model best fitting the distribution of the test values, (d) the selection of optimal diagnostic cut-off value of the test for every positive/negative situation, (e) the evaluation of performance of the combinations of correlated and uncorrelated tests. The uncertainty associated with all the variables involved is evaluated. The program works in a MS-DOS environment with EGA or higher performing graphic card.

  9. Evaluation plan for space station network interface units

    NASA Technical Reports Server (NTRS)

    Weaver, Alfred C.

    1990-01-01

    Outlined here is a procedure for evaluating network interface units (NIUs) produced for the Space Station program. The procedures should be equally applicable to the data management system (DMS) testbed NIUs produced by Honeywell and IBM. The evaluation procedures are divided into four areas. Performance measurement tools are hardware and software that must be developed in order to evaluate NIU performance. Performance tests are a series of tests, each of which documents some specific characteristic of NIU and/or network performance. In general, these performance tests quantify the speed, capacity, latency, and reliability of message transmission under a wide variety of conditions. Functionality tests are a series of tests and code inspections that demonstrate the functionality of the particular subset of ISO protocols which have been implemented in a given NIU. Conformance tests are a series of tests which would expose whether or not selected features within the ISO protocols are present and interoperable.

  10. Long-term CF6 engine performance deterioration: Evaluation of engine S/N 451-380

    NASA Technical Reports Server (NTRS)

    Kramer, W. H.; Smith, J. J.

    1978-01-01

    The performance testing and analytical teardown of CF6-6D engine serial number 451-380 which was recently removed from a DC-10 aircraft is summarized. The investigative test program was conducted inbound prior to normal overhaul/refurbishment. The performance testing included an inbound test, a test following cleaning of the low pressure turbine airfoils, and a final test after leading edge rework and cleaning the stage one fan blades. The analytical teardown consisted of detailed disassembly inspection measurements and airfoil surface finish checks of the as-received deteriorated hardware. Aspects discussed include the analysis of the test cell performance data, a complete analytical teardown report with a detailed description of all observed hardware distress, and an analytical assessment of the performance loss (deterioration) relating measured hardware conditions to losses in both specific fuel comsumption and exhaust gas temperature.

  11. Long-term CF6 engine performance deterioration: Evaluation of engine S/N 451-479

    NASA Technical Reports Server (NTRS)

    Kramer, W. H.; Smith, J. J.

    1978-01-01

    The performance testing and analytical teardown of CF6-6D engine is summarized. This engine had completed its initial installation on DC-10 aircraft. The investigative test program was conducted inbound prior to normal overhaul/refurbishment. The performance testing included an inbound test, a test following cleaning of the low pressure turbine airfoils, and a final test after leading edge rework and cleaning the stage one fan blades. The analytical teardown consisted of detailed disassembly inspection measurements and airfoil surface finish checks of the as received deteriorated hardware. Included in this report is a detailed analysis of the test cell performance data, a complete analytical teardown report with a detailed description of all observed hardware distress, and an analytical assessment of the performance loss (deterioration) relating measured hardware conditions to losses in both SFC (specific fuel consumption) and EGT (exhaust gas temperature).

  12. Performance tests of a power-electronics converter for multi-megawatt wind turbines using a grid emulator

    NASA Astrophysics Data System (ADS)

    Rizqy Averous, Nurhan; Berthold, Anica; Schneider, Alexander; Schwimmbeck, Franz; Monti, Antonello; De Doncker, Rik W.

    2016-09-01

    A vast increase of wind turbines (WT) contribution in the modern electrical grids have led to the development of grid connection requirements. In contrast to the conventional test method, testing power-electronics converters for WT using a grid emulator at Center for Wind Power Drives (CWD) RWTH Aachen University offers more flexibility for conducting test scenarios. Further analysis on the performance of the device under test (DUT) is however required when testing with grid emulator since the characteristic of the grid emulator might influence the performance of the DUT. This paper focuses on the performance analysis of the DUT when tested using grid emulator. Beside the issue regarding the current harmonics, the performance during Fault Ride-Through (FRT) is discussed in detail. A power hardware in the loop setup is an attractive solution to conduct a comprehensive study on the interaction between the power-electronics converters and the electrical grids.

  13. Association between physiological falls risk and physical performance tests among community-dwelling older adults

    PubMed Central

    Singh, Devinder KA; Pillai, Sharmila GK; Tan, Sin Thien; Tai, Chu Chiau; Shahar, Suzana

    2015-01-01

    Background Physical performance and balance declines with aging and may lead to increased risk of falls. Physical performance tests may be useful for initial fall-risk screening test among community-dwelling older adults. Physiological profile assessment (PPA), a composite falls risk assessment tool is reported to have 75% accuracy to screen for physiological falls risk. PPA correlates with Timed Up and Go (TUG) test. However, the association between many other commonly used physical performance tests and PPA is not known. The aim of the present study was to examine the association between physiological falls risk measured using PPA and a battery of physical performance tests. Methods One hundred and forty older adults from a senior citizens club in Kuala Lumpur, Malaysia (94 females, 46 males), aged 60 years and above (65.77±4.61), participated in this cross-sectional study. Participants were screened for falls risk using PPA. A battery of physical performance tests that include ten-step test (TST), short physical performance battery (SPPB), functional reach test (FRT), static balance test (SBT), TUG, dominant hand-grip strength (DHGS), and gait speed test (GST) were also performed. Spearman’s rank correlation and binomial logistic regression were performed to examine the significantly associated independent variables (physical performance tests) with falls risk (dependent variable). Results Approximately 13% older adults were at high risk of falls categorized using PPA. Significant differences (P<0.05) were demonstrated for age, TST, SPPB, FRT, SBT, TUG between high and low falls risk group. A significant (P<0.01) weak correlation was found between PPA and TST (r=0.25), TUG (r=0.27), SBT (r=0.23), SPPB (r=−0.33), and FRT (r=−0.23). Binary logistic regression results demonstrated that SBT measuring postural sways objectively using a balance board was the only significant predictor of physiological falls risk (P<0.05, odds ratio of 2.12). Conclusion The reference values of physical performance tests in our study may be used as a guide for initial falls screening to categorize high and low physiological falls risk among community-dwelling older adults. A more comprehensive assessment of falls risk can be performed thereafter for more specific intervention of underlying impairments. PMID:26316727

  14. Comparative Performance of Four Single Extreme Outlier Discordancy Tests from Monte Carlo Simulations

    PubMed Central

    Díaz-González, Lorena; Quiroz-Ruiz, Alfredo

    2014-01-01

    Using highly precise and accurate Monte Carlo simulations of 20,000,000 replications and 102 independent simulation experiments with extremely low simulation errors and total uncertainties, we evaluated the performance of four single outlier discordancy tests (Grubbs test N2, Dixon test N8, skewness test N14, and kurtosis test N15) for normal samples of sizes 5 to 20. Statistical contaminations of a single observation resulting from parameters called δ from ±0.1 up to ±20 for modeling the slippage of central tendency or ε from ±1.1 up to ±200 for slippage of dispersion, as well as no contamination (δ = 0 and ε = ±1), were simulated. Because of the use of precise and accurate random and normally distributed simulated data, very large replications, and a large number of independent experiments, this paper presents a novel approach for precise and accurate estimations of power functions of four popular discordancy tests and, therefore, should not be considered as a simple simulation exercise unrelated to probability and statistics. From both criteria of the Power of Test proposed by Hayes and Kinsella and the Test Performance Criterion of Barnett and Lewis, Dixon test N8 performs less well than the other three tests. The overall performance of these four tests could be summarized as N2≅N15 > N14 > N8. PMID:24737992

  15. Comparative performance of four single extreme outlier discordancy tests from Monte Carlo simulations.

    PubMed

    Verma, Surendra P; Díaz-González, Lorena; Rosales-Rivera, Mauricio; Quiroz-Ruiz, Alfredo

    2014-01-01

    Using highly precise and accurate Monte Carlo simulations of 20,000,000 replications and 102 independent simulation experiments with extremely low simulation errors and total uncertainties, we evaluated the performance of four single outlier discordancy tests (Grubbs test N2, Dixon test N8, skewness test N14, and kurtosis test N15) for normal samples of sizes 5 to 20. Statistical contaminations of a single observation resulting from parameters called δ from ±0.1 up to ±20 for modeling the slippage of central tendency or ε from ±1.1 up to ±200 for slippage of dispersion, as well as no contamination (δ = 0 and ε = ±1), were simulated. Because of the use of precise and accurate random and normally distributed simulated data, very large replications, and a large number of independent experiments, this paper presents a novel approach for precise and accurate estimations of power functions of four popular discordancy tests and, therefore, should not be considered as a simple simulation exercise unrelated to probability and statistics. From both criteria of the Power of Test proposed by Hayes and Kinsella and the Test Performance Criterion of Barnett and Lewis, Dixon test N8 performs less well than the other three tests. The overall performance of these four tests could be summarized as N2≅N15 > N14 > N8.

  16. Test plan for performance testing of the Eaton AC-3 electric vehicle

    NASA Astrophysics Data System (ADS)

    Crumley, R.; Heiselmann, H. W.

    1985-04-01

    An alternating current (ac) propulsion system for an electric vehicle was developed and tested. The test bed vehicle is a modified 1981 Mercury Lynx. The test plan was prepared specifically for the third modification to this test bed and identified as the Eaton AC-3. The scope of the testing done on the Eaton AC-3 includes coastdown and dynamometer tests but does not include environmental, on-road, or track testing. Coastdown testing is performed in accordance with SAE J-1263 (SAE Recommended Practice for Road Load Measurement and Dynamometer Simulation Using Coastdown Techniques).

  17. Characteristics of Pediatric Performance on a Test Battery Commonly Used in the Diagnosis of Central Auditory Processing Disorder.

    PubMed

    Weihing, Jeffrey; Guenette, Linda; Chermak, Gail; Brown, Mallory; Ceruti, Julianne; Fitzgerald, Krista; Geissler, Kristin; Gonzalez, Jennifer; Brenneman, Lauren; Musiek, Frank

    2015-01-01

    Although central auditory processing disorder (CAPD) test battery performance has been examined in adults with neurologic lesions of the central auditory nervous system (CANS), similar data on children being referred for CAPD evaluations are sparse. This study characterizes CAPD test battery performance in children using tests commonly administered to diagnose the disorder. Specifically, this study describes failure rates for various test combinations, relationships between CAPD tests used in the battery, and the influence of cognitive function on CAPD test performance and CAPD diagnosis. A comparison is also made between the performance of children with CAPD and data from patients with neurologic lesions of the CANS. A retrospective study. Fifty-six pediatric patients were referred for CAPD testing. Participants were administered four CAPD tests, including frequency patterns (FP), low-pass filtered speech (LPFS), dichotic digits (DD), and competing sentences (CS). In addition, they were given the Wechsler Intelligence Scale for Children (WISC). Descriptive analyses examined the failure rates of various test combinations, as well as how often children with CAPD failed certain combinations when compared with adults with CANS lesions. A principal components analysis was performed to examine interrelationships between tests. Correlations and regressions were conducted to determine the relationship between CAPD test performance and the WISC. Results showed that the FP and LPFS tests were most commonly failed by children with CAPD. Two-test combinations that included one or both of these two tests and excluded DD tended to be failed more often. Including the DD and CS test in a battery benefited specificity. Tests thought to measure interhemispheric transfer tended to be correlated. Compared with adult patients with neurologic lesions, children with CAPD tended to fail LPFS more frequently and DD less frequently. Both groups failed FP with relatively equal frequency. The two-test combination that showed the highest failure rate for children with CAPD was LPFS-FP. Comparison with adults with CANS lesions, however, suggests that the mechanisms underlying LPFS performance in children need to be better understood. The two-test combination that showed the next highest failure rates among children with CAPD and did not include LPFS was CS-FP. If it is desirable to use a dichotic measure that has a lower linguistic load than CS then DD can be substituted for CS despite the slightly lower failure rate of the DD-FP battery. American Academy of Audiology.

  18. Reliability and validity of functional performance tests in dancers with hip dysfunction.

    PubMed

    Kivlan, Benjamin R; Carcia, Christopher R; Clemente, F Richard; Phelps, Amy L; Martin, Robroy L

    2013-08-01

    Quasi-experimental, repeated measures. Functional performance tests that identify hip joint impairments and assess the effect of intervention have not been adequately described for dancers. The purpose of this study was to examine the reliability and validity of hop and balance tests among a group of dancers with musculoskeletal pain in the hip region. NINETEEN FEMALE DANCERS (AGE: 18.90±1.11 years; height: 164.85±6.95 cm; weight: 60.37±8.29 kg) with unilateral hip pain were assessed utilizing the cross-over reach, medial triple hop, lateral triple hop, and cross-over hop tests on two occasions, 2 days apart. Test-retest reliability and comparisons between the involved and uninvolved side for each respective test were determined. Intra-class correlation coefficients for the functional performance tests ranged from 0.89-0.96. The cross-over reach test had a SEM of 2.79 cm and a MDC of 7.73 cm. The medial and lateral triple hop tests had SEM values of 7.51 cm and 8.17 cm, and MDC values of 20.81 cm and 22.62 cm, respectively. The SEM was 0.15 seconds and the MDC was 0.42 seconds for the cross-over hop test. Performance on the medial triple hop test was significantly less on the involved side (370.21±38.26 cm) compared to the uninvolved side (388.05±41.49 cm); t(18) = -4.33, p<0.01. The side-to-side comparisons of the cross-over reach test (involved mean=61.68±10.9 cm; uninvolved mean=61.69±8.63 cm); t(18) = -0.004, p=0.99, lateral triple hop test (involved mean=306.92±35.79 cm; uninvolved mean=310.68±24.49 cm); t(18) = -0.55, p=0.59, and cross-over hop test (involved mean=2.49±0.34 seconds; uninvolved mean= 2.61±0.42 seconds; t(18) = -1.84, p=0.08) were not statistically different between sides. The functional performance tests used in this study can be reliably performed on dancers with unilateral hip pain. The medial triple hop test was the only functional performance test with evidence of validity in side-to-side comparisons. These results suggest that the medial triple hop test may be a reliable and valid functional performance test to assess impairments related to hip pain among dancers. 3b. Non-consecutive cohort study.

  19. RELIABILITY AND VALIDITY OF FUNCTIONAL PERFORMANCE TESTS IN DANCERS WITH HIP DYSFUNCTION

    PubMed Central

    Carcia, Christopher R.; Clemente, F. Richard; Phelps, Amy L.; Martin, RobRoy L.

    2013-01-01

    Study Design: Quasi-experimental, repeated measures. Purpose/Background: Functional performance tests that identify hip joint impairments and assess the effect of intervention have not been adequately described for dancers. The purpose of this study was to examine the reliability and validity of hop and balance tests among a group of dancers with musculoskeletal pain in the hip region. Methods: Nineteen female dancers (age: 18.90±1.11 years; height: 164.85±6.95 cm; weight: 60.37±8.29 kg) with unilateral hip pain were assessed utilizing the cross-over reach, medial triple hop, lateral triple hop, and cross-over hop tests on two occasions, 2 days apart. Test-retest reliability and comparisons between the involved and uninvolved side for each respective test were determined. Results: Intra-class correlation coefficients for the functional performance tests ranged from 0.89-0.96. The cross-over reach test had a SEM of 2.79 cm and a MDC of 7.73 cm. The medial and lateral triple hop tests had SEM values of 7.51 cm and 8.17 cm, and MDC values of 20.81 cm and 22.62 cm, respectively. The SEM was 0.15 seconds and the MDC was 0.42 seconds for the cross-over hop test. Performance on the medial triple hop test was significantly less on the involved side (370.21±38.26 cm) compared to the uninvolved side (388.05±41.49 cm); t(18) = −4.33, p<0.01. The side-to-side comparisons of the cross-over reach test (involved mean=61.68±10.9 cm; uninvolved mean=61.69±8.63 cm); t(18) = −0.004, p=0.99, lateral triple hop test (involved mean=306.92±35.79 cm; uninvolved mean=310.68±24.49 cm); t(18) = −0.55, p=0.59, and cross-over hop test (involved mean=2.49±0.34 seconds; uninvolved mean= 2.61±0.42 seconds; t(18) = −1.84, p=0.08) were not statistically different between sides. Conclusion: The functional performance tests used in this study can be reliably performed on dancers with unilateral hip pain. The medial triple hop test was the only functional performance test with evidence of validity in side-to-side comparisons. These results suggest that the medial triple hop test may be a reliable and valid functional performance test to assess impairments related to hip pain among dancers. Level of Evidence: 3b. Non-consecutive cohort study PMID:24175123

  20. MOON-test - determination of motor performance in the pediatric oncology.

    PubMed

    Götte, M; Kesting, S; Albrecht, C; Worth, A; Bös, K; Boos, J

    2013-05-01

    Pediatric cancer patients suffer from various negative consequences due to the disease, the medical therapy and the inactivity during the intensive treatment. Only few studies have systematically identified the adverse effects of cancer on motor performance in childhood. To determine the motor performance of pediatric cancer patients, a motor performance test was developed which is applicable for this specific patient group. Eight test items with reference values for healthy children were merged to the MOON-test (test for motor performance in the oncology). MOON was tested for feasibility and acceptance in 33 patients aged 4-18 years. Feasibility was confirmed for children with different types of cancer (hematological malignancies and solid tumors) and with amputation, endoprosthesis, during aplasia as well as reduced general condition. Furthermore the patients showed a broad acceptance. Based on the study findings, the use of MOON-test as a standardized motor performance diagnostic tool in clinical routine of oncological acute clinics as well as rehabilitation clinics can be recommended.· © Georg Thieme Verlag KG Stuttgart · New York.

  1. Performance and Symptom Validity Testing as a Function of Medical Board Evaluation in U.S. Military Service Members with a History of Mild Traumatic Brain Injury.

    PubMed

    Armistead-Jehle, Patrick; Cole, Wesley R; Stegman, Robert L

    2018-02-01

    The study was designed to replicate and extend pervious findings demonstrating the high rates of invalid neuropsychological testing in military service members (SMs) with a history of mild traumatic brain injury (mTBI) assessed in the context of a medical evaluation board (MEB). Two hundred thirty-one active duty SMs (61 of which were undergoing an MEB) underwent neuropsychological assessment. Performance validity (Word Memory Test) and symptom validity (MMPI-2-RF) test data were compared across those evaluated within disability (MEB) and clinical contexts. As with previous studies, there were significantly more individuals in an MEB context that failed performance (MEB = 57%, non-MEB = 31%) and symptom validity testing (MEB = 57%, non-MEB = 22%) and performance validity testing had a notable affect on cognitive test scores. Performance and symptom validity test failure rates did not vary as a function of the reason for disability evaluation when divided into behavioral versus physical health conditions. These data are consistent with past studies, and extends those studies by including symptom validity testing and investigating the effect of reason for MEB. This and previous studies demonstrate that more than 50% of SMs seen in the context of an MEB will fail performance validity tests and over-report on symptom validity measures. These results emphasize the importance of using both performance and symptom validity testing when evaluating SMs with a history of mTBI, especially if they are being seen for disability evaluations, in order to ensure the accuracy of cognitive and psychological test data. Published by Oxford University Press 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  2. The first PANDA tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dreier, J.; Huggenberger, M.; Aubert, C.

    1996-08-01

    The PANDA test facility at PSI in Switzerland is used to study the long-term Simplified Boiling Water Reactor (SBWR) Passive Containment Cooling System (PCCS) performance. The PANDA tests demonstrate performance on a larger scale than previous tests and examine the effects of any non-uniform spatial distributions of steam and non-condensables in the system. The PANDA facility has a 1:1 vertical scale, and 1:25 ``system`` scale (volume, power, etc.). Steady-state PCCS condenser performance tests and extensive facility characterization tests have been completed. Transient system behavior tests were conducted late in 1995; results from the first three transient tests (M3 series) aremore » reviewed. The first PANDA tests showed that the overall global behavior of the SBWR containment was globally repeatable and very favorable; the system exhibited great ``robustness.``« less

  3. High Pressure Quick Disconnect Particle Impact Tests

    NASA Technical Reports Server (NTRS)

    Peralta, Stephen; Rosales, Keisa; Smith, Sarah R.; Stoltzfus, Joel M.

    2007-01-01

    To determine whether there is a particle impact ignition hazard in the quick disconnects (QDs) in the Environmental Control and Life Support System (ECLSS) on the International Space Station (ISS), NASA Johnson Space Center requested White Sands Test Facility (WSTF) to perform particle impact testing. Testing was performed from November 2006 through May 2007 and included standard supersonic and subsonic particle impact tests on 15-5 PH stainless steel, as well as tests performed on a QD simulator. This report summarizes the particle impact tests completed at WSTF. Although there was an ignition in Test Series 4, it was determined the ignition was caused by the presence of a machining imperfection. The sum of all the test results indicates that there is no particle impact ignition hazard in the ISS ECLSS QDs.

  4. Gaia challenging performances verification: combination of spacecraft models and test results

    NASA Astrophysics Data System (ADS)

    Ecale, Eric; Faye, Frédéric; Chassat, François

    2016-08-01

    To achieve the ambitious scientific objectives of the Gaia mission, extremely stringent performance requirements have been given to the spacecraft contractor (Airbus Defence and Space). For a set of those key-performance requirements (e.g. end-of-mission parallax, maximum detectable magnitude, maximum sky density or attitude control system stability), this paper describes how they are engineered during the whole spacecraft development process, with a focus on the end-to-end performance verification. As far as possible, performances are usually verified by end-to-end tests onground (i.e. before launch). However, the challenging Gaia requirements are not verifiable by such a strategy, principally because no test facility exists to reproduce the expected flight conditions. The Gaia performance verification strategy is therefore based on a mix between analyses (based on spacecraft models) and tests (used to directly feed the models or to correlate them). Emphasis is placed on how to maximize the test contribution to performance verification while keeping the test feasible within an affordable effort. In particular, the paper highlights the contribution of the Gaia Payload Module Thermal Vacuum test to the performance verification before launch. Eventually, an overview of the in-flight payload calibration and in-flight performance verification is provided.

  5. Use of the Marshall Space Flight Center solar simulator in collector performance evaluation

    NASA Technical Reports Server (NTRS)

    Humphries, W. R.

    1978-01-01

    Actual measured values from simulator checkout tests are detailed. Problems encountered during initial startup are discussed and solutions described. Techniques utilized to evaluate collector performance from simulator test data are given. Performance data generated in the simulator are compared to equivalent data generated during natural outdoor testing. Finally, a summary of collector performance parameters generated to date as a result of simulator testing are given.

  6. Effort, symptom validity testing, performance validity testing and traumatic brain injury.

    PubMed

    Bigler, Erin D

    2014-01-01

    To understand the neurocognitive effects of brain injury, valid neuropsychological test findings are paramount. This review examines the research on what has been referred to a symptom validity testing (SVT). Above a designated cut-score signifies a 'passing' SVT performance which is likely the best indicator of valid neuropsychological test findings. Likewise, substantially below cut-point performance that nears chance or is at chance signifies invalid test performance. Significantly below chance is the sine qua non neuropsychological indicator for malingering. However, the interpretative problems with SVT performance below the cut-point yet far above chance are substantial, as pointed out in this review. This intermediate, border-zone performance on SVT measures is where substantial interpretative challenges exist. Case studies are used to highlight the many areas where additional research is needed. Historical perspectives are reviewed along with the neurobiology of effort. Reasons why performance validity testing (PVT) may be better than the SVT term are reviewed. Advances in neuroimaging techniques may be key in better understanding the meaning of border zone SVT failure. The review demonstrates the problems with rigidity in interpretation with established cut-scores. A better understanding of how certain types of neurological, neuropsychiatric and/or even test conditions may affect SVT performance is needed.

  7. Full scale evaluation of diffuser ageing with clean water oxygen transfer tests.

    PubMed

    Krampe, J

    2011-01-01

    Aeration is a crucial part of the biological wastewater treatment in activated sludge systems and the main energy user of WWTPs. Approximately 50 to 60% of the total energy consumption of a WWTP can be attributed to the aeration system. The performance of the aeration system, and in the case of fine bubble diffused aeration the diffuser performance, has a significant impact on the overall plant efficiency. This paper seeks to isolate the changes of the diffuser performance over time by eliminating all other influencing parameters like sludge retention time, surfactants and reactor layout. To achieve this, different diffusers have been installed and tested in parallel treatment trains in two WWTPs. The diffusers have been performance tested in clean water tests under new conditions and after one year of operation. A set of material property tests describing the diffuser membrane quality was also performed. The results showed a significant drop in the performance of the EPDM diffuser in the first year which resulted in similar oxygen transfer efficiency around 16 g/m3/m for all tested systems. Even though the tested silicone diffusers did not show a drop in performance they had a low efficiency in the initial tests. The material properties indicate that the EPDM performance loss is partly due to the washout of additives.

  8. GPS Device Testing Based on User Performance Metrics

    DOT National Transportation Integrated Search

    2015-10-02

    1. Rationale for a Test Program Based on User Performance Metrics ; 2. Roberson and Associates Test Program ; 3. Status of, and Revisions to, the Roberson and Associates Test Program ; 4. Comparison of Roberson and DOT/Volpe Programs

  9. New Hampshire binder and mix review.

    DOT National Transportation Integrated Search

    2012-08-01

    This review was initiated to compare relative rut testing and simple performance tests (now known as Asphalt Mix : Performance Tests) for the New Hampshire inch mix with 15% Recycled Asphalt Pavement (RAP). The tested mixes were : made from ...

  10. Crash Tests of Work Zone Traffic Control Devices

    DOT National Transportation Integrated Search

    1990-02-01

    Full-scale vehicle crash tests evaluated performance of typical work zone traffic control devices. Modified test procedures and evaluation criteria from NCHRP Report 230 were used in 108 tests, providing significant insight into impact performance. P...

  11. Effect of Propellant Flowrate and Purity on Carbon Deposition in LO2/Methane Gas Generators

    NASA Technical Reports Server (NTRS)

    Bossard, J. A.; Burkhardt, W. M.; Niiya, K. Y.; Braam, F.

    1989-01-01

    The generation and deposition of carbon was studied in the Carbon Deposition Program using subscale hardware with LO2/Liquid Natural Gas (LNG) and LO2/Methane propellants at low mixture ratios. The purpose of the testing was to evaluate the effect of methane purity and full scale injection density on carbon deposition. The LO2/LNG gas generator/preburner testing was performed at mixture ratios between 0.24 and 0.58 and chamber pressures from 5.8 to 9.4 MPa (840 to 1370 psia). A total of seven 200 second duration tests were performed. The LNG testing occurred at low injection densities, similar to the previous LO2/RP-1, LO2/propane, and LO2/methane testing performed on the carbon deposition program. The current LO2/methane test series occurred at an injection density factor of approximately 10 times higher than the previous testing. The high injection density LO2/methane testing was performed at mixture ratios between from 0.23 to 0.81 and chamber pressures from 6.4 to 15.2 MPa (925 to 2210 psia). A total of nine high injection density tests were performed. The testing performed demonstrated that low purity methane (LNG) did not produce any detectable change in carbon deposition when compared to pure methane. In addition, the C* performance and the combustion gas temperatures measured were similar to those obtained for pure methane. Similar results were obtained testing pure methane at higher propellant injection densities with coarse injector elements.

  12. Cryogenic Thermal Performance Testing of Bulk-Fill and Aerogel Insulation Materials

    NASA Astrophysics Data System (ADS)

    Scholtens, B. E.; Fesmire, J. E.; Sass, J. P.; Augustynowicz, S. D.; Heckle, K. W.

    2008-03-01

    Thermal conductivity testing under actual-use conditions is a key to understanding how cryogenic thermal insulation systems perform in regard to engineering, economics, and materials factors. The Cryogenics Test Laboratory at NASA's Kennedy Space Center tested a number of bulk-fill insulation materials, including aerogel beads, glass bubbles, and perlite powder, using a new cylindrical cryostat. Boundary temperatures for the liquid nitrogen boiloff method were 78 K and 293 K. Tests were performed as a function of cold vacuum pressure under conditions ranging from high vacuum to no vacuum. Results were compared with those from complementary test methods in the range of 20 K to 300 K. Various testing techniques are required to completely understand the operating performance of a material and to provide data for answers to design engineering questions.

  13. The Quantitative Science of Evaluating Imaging Evidence.

    PubMed

    Genders, Tessa S S; Ferket, Bart S; Hunink, M G Myriam

    2017-03-01

    Cardiovascular diagnostic imaging tests are increasingly used in everyday clinical practice, but are often imperfect, just like any other diagnostic test. The performance of a cardiovascular diagnostic imaging test is usually expressed in terms of sensitivity and specificity compared with the reference standard (gold standard) for diagnosing the disease. However, evidence-based application of a diagnostic test also requires knowledge about the pre-test probability of disease, the benefit of making a correct diagnosis, the harm caused by false-positive imaging test results, and potential adverse effects of performing the test itself. To assist in clinical decision making regarding appropriate use of cardiovascular diagnostic imaging tests, we reviewed quantitative concepts related to diagnostic performance (e.g., sensitivity, specificity, predictive values, likelihood ratios), as well as possible biases and solutions in diagnostic performance studies, Bayesian principles, and the threshold approach to decision making. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. Thermoelectric generator testing and RTG degradation mechanisms evaluation. Progress report No. 33

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lockwood, A.; Stapfer, G.

    1979-12-01

    The n-type selenide legs after 10,600 hours continue to show agreement with the 3M Co. published data. In the ingradient testing after 11,378 hours the n-legs show comparable performance to the reported 3M data. The new design p-type legs were placed on test. The remaining MHW generator on test Q1-A has accumulated 19,567 hours and performance remains stable. Three 18 couple modules S/N-1, 2, and 3 previously tested at RCA were received for JPL test and evaluation. S/N-1 has 1700 hours testing at JPL with results indistinguishable from those at the end of RCA testing in 1977. The performances ofmore » LES 8/9 generators are following DEGRA predications after 31,824 hours. The performance of the Voyager 1 and 2 RTGs is reported after 19,577 hours and 20,122 hours of operation, respectively.« less

  15. Space Launch System Base Heating Test: Sub-Scale Rocket Engine/Motor Design, Development & Performance Analysis

    NASA Technical Reports Server (NTRS)

    Mehta, Manish; Seaford, Mark; Kovarik, Brian; Dufrene, Aaron; Solly, Nathan

    2014-01-01

    ATA-002 Technical Team has successfully designed, developed, tested and assessed the SLS Pathfinder propulsion systems for the Main Base Heating Test Program. Major Outcomes of the Pathfinder Test Program: Reach 90% of full-scale chamber pressure Achieved all engine/motor design parameter requirements Reach steady plume flow behavior in less than 35 msec Steady chamber pressure for 60 to 100 msec during engine/motor operation Similar model engine/motor performance to full-scale SLS system Mitigated nozzle throat and combustor thermal erosion Test data shows good agreement with numerical prediction codes Next phase of the ATA-002 Test Program Design & development of the SLS OML for the Main Base Heating Test Tweak BSRM design to optimize performance Tweak CS-REM design to increase robustness MSFC Aerosciences and CUBRC have the capability to develop sub-scale propulsion systems to meet desired performance requirements for short-duration testing.

  16. Testing of CMA-2000 Microwave Landing System (MLS) airborne receiver

    NASA Astrophysics Data System (ADS)

    Labreche, L.; Murfin, A. J.

    1989-09-01

    Microwave landing system (MLS) is a precision approach and landing guidance system which provides position information and various air to ground data. Position information is provided on a wide coverage sector and is determined by an azimuth angle measurement, an elevation angle measurement, and a range measurement. MLS performance standards and testing of the MLS airborne receiver is mainly governed by Technical Standard Order TSO-C104 issued by the Federal Aviation Administration. This TSO defines detailed test procedures for use in determining the required performance under standard and stressed conditions. It also imposes disciplines on software development and testing procedures. Testing performed on the CMA-2000 MLS receiver and methods used in its validation are described. A computer automated test system has been developed to test for compliance with RTCA/DO-177 Minimum Operation Performance Standards. Extensive software verification and traceability tests designed to ensure compliance with RTCA/DO-178 are outlined.

  17. Reliability of a Computerized Neurocognitive Test in Baseline Concussion Testing of High School Athletes.

    PubMed

    MacDonald, James; Duerson, Drew

    2015-07-01

    Baseline assessments using computerized neurocognitive tests are frequently used in the management of sport-related concussions. Such testing is often done on an annual basis in a community setting. Reliability is a fundamental test characteristic that should be established for such tests. Our study examined the test-retest reliability of a computerized neurocognitive test in high school athletes over 1 year. Repeated measures design. Two American high schools. High school athletes (N = 117) participating in American football or soccer during the 2011-2012 and 2012-2013 academic years. All study participants completed 2 baseline computerized neurocognitive tests taken 1 year apart at their respective schools. The test measures performance on 4 cognitive tasks: identification speed (Attention), detection speed (Processing Speed), one card learning accuracy (Learning), and one back speed (Working Memory). Reliability was assessed by measuring the intraclass correlation coefficient (ICC) between the repeated measures of the 4 cognitive tasks. Pearson and Spearman correlation coefficients were calculated as a secondary outcome measure. The measure for identification speed performed best (ICC = 0.672; 95% confidence interval, 0.559-0.760) and the measure for one card learning accuracy performed worst (ICC = 0.401; 95% confidence interval, 0.237-0.542). All tests had marginal or low reliability. In a population of high school athletes, computerized neurocognitive testing performed in a community setting demonstrated low to marginal test-retest reliability on baseline assessments 1 year apart. Further investigation should focus on (1) improving the reliability of individual tasks tested, (2) controlling for external factors that might affect test performance, and (3) identifying the ideal time interval to repeat baseline testing in high school athletes. Computerized neurocognitive tests are used frequently in high school athletes, often within a model of baseline testing of asymptomatic individuals before the start of a sporting season. This study adds to the evidence that suggests in this population such testing may lack sufficient reliability to support clinical decision making.

  18. Arc Jet Screening Tests Of Phase 1 Orbiter Tile Repair Materials and Uncoated RSI High Temperature Emittance Measurements

    NASA Technical Reports Server (NTRS)

    DelPapa, Steven V.

    2005-01-01

    Arc jet tests of candidate tile repair materials and baseline Orbiter uncoated reusable surface insulation (RSI) were performed in the Johnson Space Center's (JSC) Atmospheric Reentry Materials and Structures Evaluation Facility (ARMSEF) from June 23, 2003, through August 19, 2003. These tests were performed to screen candidate tile repair materials by verifying the high temperature performance and determining the thermal stability. In addition, tests to determine the surface emissivity at high temperatures and the geometric shrinkage of bare RSI were performed. In addition, tests were performed to determine the surface emissivity at high temperatures and the geometric shrinkage of uncoated RSI.

  19. Hot-Fire Testing of 5N and 22N HPGP Thrusters

    NASA Technical Reports Server (NTRS)

    Burnside, Christopher G.; Pedersen, Kevin W.; Pierce, Charles W.

    2015-01-01

    This hot-fire test continues NASA investigation of green propellant technologies for future missions. To show the potential for green propellants to replace some hydrazine systems in future spacecraft, NASA Marshall Space Flight Center (MSFC) is continuing to embark on hot-fire test campaigns with various green propellant blends.NASA completed hot-fire testing of 5N and 22N HPGP thrusters at the Marshall Space Flight Center’s Component Development Area altitude test stand in April 2015. Both thrusters are ground test articles and not flight ready units, but are representative of potential flight hardware with a known path towards flight application. The purpose of the 5N testing was to perform facility check-outs and generate a small set of data for comparison to ECAPS and Orbital ATK data sets. The 5N thruster performed as expected with thrust and propellant flow-rate data generated that are similar to previous testing at Orbital ATK. Immediately following the 5N testing, and using the same facility, the 22N testing was conducted on the same test stand with the purpose of demonstrating the 22N performance. The results of 22N testing indicate it performed as expected.The results of the hot-fire testing are presented in this paper and presentation.

  20. The relationship between the yo-yo tests, anaerobic performance and aerobic performance in young soccer players.

    PubMed

    Karakoç, Barış; Akalan, Cengiz; Alemdaroğlu, Utku; Arslan, Erşan

    2012-12-01

    The purposes of this study were to determine the relationship between performance in the Yo-Yo intermittent recovery test level 1 (YIRT1), the Yo-Yo intermittent recovery test level 2 (YIRT2) and the Yo-Yo endurance test (continuous) (YET) with maximal oxygen uptake (VO2max) and Wingate anaerobic performance (WaNT) test results in young soccer players (age 15.00 ± 0.0 years, body height 176.3 ± 4.2 cm and body mass 68.1 ± 3.6 kg). An ergospirometry device was used during the treadmill test (TRT) to determine VO2max. At the end of the study, significant differences were found between the Yo-Yo tests and TRT in terms of HRmax (TRT = 195,92, YIRT1 = 197,83, YIRT2 = 198,5 YET = 198) (p > 0.05). While there were moderate correlations between VO2max and YIRT 1-2 performances (respectively, r = 0.56, r = 0.53), there was only a weak relationship between VO2max and YET performance (r = 0.43) (distance covered). There were also moderate significant negative correlations between performance in the YIRT2 and peak power measured in the WaNT (r = -0.55), although there were no significant correlations between performance in the three tests and average power. A moderate negative correlation was found between performance in the YIRT2 and Fatigue index (FI) (r = -0,66). In conclusion, the YIRT2 may be a more suitable field test for determining both aerobic and anaerobic performance in soccer players.

  1. The Relationship Between the Yo-Yo Tests, Anaerobic Performance and Aerobic Performance in Young Soccer Players

    PubMed Central

    Karakoç, Barış; Akalan, Cengiz; Alemdaroğlu, Utku; Arslan, Erşan

    2012-01-01

    The purposes of this study were to determine the relationship between performance in the Yo-Yo intermittent recovery test level 1 (YIRT1), the Yo-Yo intermittent recovery test level 2 (YIRT2) and the Yo-Yo endurance test (continuous) (YET) with maximal oxygen uptake (VO2max) and Wingate anaerobic performance (WaNT) test results in young soccer players (age 15.00 ± 0.0 years, body height 176.3 ± 4.2 cm and body mass 68.1 ± 3.6 kg). An ergospirometry device was used during the treadmill test (TRT) to determine VO2max. At the end of the study, significant differences were found between the Yo-Yo tests and TRT in terms of HRmax (TRT = 195,92, YIRT1 = 197,83, YIRT2 = 198,5 YET = 198) (p > 0.05). While there were moderate correlations between VO2max and YIRT 1–2 performances (respectively, r = 0.56, r = 0.53), there was only a weak relationship between VO2max and YET performance (r = 0.43) (distance covered). There were also moderate significant negative correlations between performance in the YIRT2 and peak power measured in the WaNT (r = −0.55), although there were no significant correlations between performance in the three tests and average power. A moderate negative correlation was found between performance in the YIRT2 and Fatigue index (FI) (r = −0,66). In conclusion, the YIRT2 may be a more suitable field test for determining both aerobic and anaerobic performance in soccer players. PMID:23486008

  2. Uprated OMS Engine Status-Sea Level Testing Results

    NASA Technical Reports Server (NTRS)

    Bertolino, J. D.; Boyd, W. C.

    1990-01-01

    The current Space Shuttle Orbital Maneuvering Engine (OME) is pressure fed, utilizing storable propellants. Performance uprating of this engine, through the use of a gas generator driven turbopump to increase operating pressure, is being pursued by the NASA Johnson Space Center (JSC). Component level design, fabrication, and test activities for this engine system have been on-going since 1984. More recently, a complete engine designated the Integrated Component Test Bed (ICTB), was tested at sea level conditions by Aerojet. A description of the test hardware and results of the sea level test program are presented. These results, which include the test condition operating envelope and projected performance at altitude conditions, confirm the capability of the selected Uprated OME (UOME) configuration to meet or exceed performance and operational requirements. Engine flexibility, demonstrated through testing at two different operational mixture ratios, along with a summary of projected Space Shuttle performance enhancements using the UOME, are discussed. Planned future activities, including ICTB tests at simulated altitude conditions, and recommendations for further engine development, are also discussed.

  3. Effects of three pesticides on the avoidance behavior of earthworms in laboratory tests performed under temperate and tropical conditions.

    PubMed

    Garcia, Marcos; Römbke, Jörg; de Brito, Marcus Torres; Scheffczyk, Adam

    2008-05-01

    Little research has been performed on the impact of pesticides on earthworms under tropical conditions. Taking into consideration the often-limited resources in tropical countries, simple screening tests are needed. Therefore, it was investigated whether three pesticides relevant for the Brazilian Amazon (benomyl, carbendazim, lambda-cyhalothrin) affect the avoidance behavior of the earthworm Eisenia fetida. The tests were performed for two days according to ISO guideline 17512 but were adapted to tropical conditions (i.e. test substrate, test organism and temperature). The results indicate that this test gives reproducible and reliable results. Toxicity values (NOEC, EC50) are lower than those determined in 14 day-acute mortality tests and are approximately in the same range such as those found in 56 day-chronic reproduction tests with the same earthworm species, which were performed in parallel. Therefore, the use of the earthworm avoidance tests is recommended as a screening tool for the risk assessment of pesticides.

  4. Performance validity testing in neuropsychology: a clinical guide, critical review, and update on a rapidly evolving literature.

    PubMed

    Lippa, Sara M

    2018-04-01

    Over the past two decades, there has been much research on measures of response bias and myriad measures have been validated in a variety of clinical and research samples. This critical review aims to guide clinicians through the use of performance validity tests (PVTs) from test selection and administration through test interpretation and feedback. Recommended cutoffs and relevant test operating characteristics are presented. Other important issues to consider during test selection, administration, interpretation, and feedback are discussed including order effects, coaching, impact on test data, and methods to combine measures and improve predictive power. When interpreting performance validity measures, neuropsychologists must use particular caution in cases of dementia, low intelligence, English as a second language/minority cultures, or low education. PVTs provide valuable information regarding response bias and, under the right circumstances, can provide excellent evidence of response bias. Only after consideration of the entire clinical picture, including validity test performance, can concrete determinations regarding the validity of test data be made.

  5. Quality assurance and quality improvement in U.S. clinical molecular genetic laboratories.

    PubMed

    Chen, Bin; Richards, C Sue; Wilson, Jean Amos; Lyon, Elaine

    2011-04-01

    A robust quality-assurance program is essential for laboratories that perform molecular genetic testing to maintain high-quality testing and be able to address challenges associated with performance or delivery of testing services as the use of molecular genetic tests continues to expand in clinical and public health practice. This unit discusses quality-assurance and quality-improvement considerations that are critical for molecular genetic testing performed for heritable diseases and conditions. Specific discussion is provided on applying regulatory standards and best practices in establishing/verifying test performance, ensuring quality of the total testing process, monitoring and maintaining personnel competency, and continuing quality improvement. The unit provides a practical reference for laboratory professionals to use in recognizing and addressing essential quality-assurance issues in human molecular genetic testing. It should also provide useful information for genetics researchers, trainees, and fellows in human genetics training programs, as well as others who are interested in quality assurance and quality improvement for molecular genetic testing. 2011 by John Wiley & Sons, Inc.

  6. An Evaluation of the Additional Acoustic Power Needed to Overcome the Effects of a Test-Article's Absorption During Reverberant Chamber Acoustic Testing of Spaceflight Hardware

    NASA Technical Reports Server (NTRS)

    Hozman, Aron D.; Hughes, William O.

    2014-01-01

    The exposure of a customer's aerospace test-article to a simulated acoustic launch environment is typically performed in a reverberant acoustic test chamber. The acoustic pre-test runs that will ensure that the sound pressure levels of this environment can indeed be met by a test facility are normally performed without a test-article dynamic simulator of representative acoustic absorption and size. If an acoustic test facility's available acoustic power capability becomes maximized with the test-article installed during the actual test then the customer's environment requirement may become compromised. In order to understand the risk of not achieving the customer's in-tolerance spectrum requirement with the test-article installed, an acoustic power margin evaluation as a function of frequency may be performed by the test facility. The method for this evaluation of acoustic power will be discussed in this paper. This method was recently applied at the NASA Glenn Research Center Plum Brook Station's Reverberant Acoustic Test Facility for the SpaceX Falcon 9 Payload Fairing acoustic test program.

  7. An Evaluation of the Additional Acoustic Power Needed to Overcome the Effects of a Test-Article's Absorption during Reverberant Chamber Acoustic Testing of Spaceflight Hardware

    NASA Technical Reports Server (NTRS)

    Hozman, Aron D.; Hughes, William O.

    2014-01-01

    The exposure of a customers aerospace test-article to a simulated acoustic launch environment is typically performed in a reverberant acoustic test chamber. The acoustic pre-test runs that will ensure that the sound pressure levels of this environment can indeed be met by a test facility are normally performed without a test-article dynamic simulator of representative acoustic absorption and size. If an acoustic test facilitys available acoustic power capability becomes maximized with the test-article installed during the actual test then the customers environment requirement may become compromised. In order to understand the risk of not achieving the customers in-tolerance spectrum requirement with the test-article installed, an acoustic power margin evaluation as a function of frequency may be performed by the test facility. The method for this evaluation of acoustic power will be discussed in this paper. This method was recently applied at the NASA Glenn Research Center Plum Brook Stations Reverberant Acoustic Test Facility for the SpaceX Falcon 9 Payload Fairing acoustic test program.

  8. Individual Characteristics and Unit Performance: A Review of Research and Methods

    DTIC Science & Technology

    1985-02-01

    behavioral segments, improves performance. Simu- lation exercises , especially those employing new high-technology devices, provide surrogate...high-technology training simulation exercise MOB Military Occupational Specialty ORTT Operational Readiness Training Test-a field test REALTRAIN A...REAListic TRAINing simulation exercise SAM Surface-to-Air Missile SAT Scholastic Aptitude Test SQT Skill Qualification Test-an Army performance meas

  9. Learner-Centered Instruction (LCI). Volume 5. Description of the Job Performance Test.

    ERIC Educational Resources Information Center

    Pieper, William J.; And Others

    An account is presented of the development of a job performance test for the Learner Centered Instruction (LCI) weapon control systems mechanic/technician Air Force course. The performance test was administered to the LCI experimental course subjects as well as the control course subjects upon graduation. Test items are, for the most part, based…

  10. Sub-maximal and maximal Yo-Yo intermittent endurance test level 2: heart rate response, reproducibility and application to elite soccer.

    PubMed

    Bradley, Paul S; Mohr, M; Bendiksen, M; Randers, M B; Flindt, M; Barnes, C; Hood, P; Gomez, A; Andersen, Jesper L; Di Mascio, M; Bangsbo, J; Krustrup, P

    2011-06-01

    The aims of this study were to (1) determine the reproducibility of sub-maximal and maximal versions of the Yo-Yo intermittent endurance test level 2 (Yo-Yo IE2 test), (2) assess the relationship between the Yo-Yo IE2 test and match performance and (3) quantify the sensitivity of the Yo-Yo IE2 test to detect test-retest changes and discriminate between performance for different playing standards and positions in elite soccer. Elite (n = 148) and sub-elite male (n = 14) soccer players carried out the Yo-Yo IE2 test on several occasions over consecutive seasons. Test-retest coefficient of variation (CV) in Yo-Yo IE2 test performance and heart rate after 6 min were 3.9% (n = 37) and 1.4% (n = 32), respectively. Elite male senior and youth U19 players Yo-Yo IE2 performances were better (P < 0.01) than elite youth U16s and sub-elite players (2,603 ± 451 and 2,534 ± 549 vs. 1,855 ± 535 vs. 1,749 ± 382 m). The intra- and inter-season CV for Yo-Yo IE2 test performance were 4.2 and 5.6%, respectively. A correlation was observed (P < 0.05) between Yo-Yo IE2 test performance and the total (r = 0.74) and high-intensity (r = 0.58) running distance covered in a match. A correlation was also evident (P < 0.01) between Yo-Yo IE2 test heart rate after 6 min expressed in percentage of maximal heart rate and the peak values for high-intensity running performed by midfielders in 5-min (r = -0.71), 15-min (r = -0.75) and 45-min periods (r = -0.77). The present data demonstrate that the Yo-Yo IE2 test is reproducible and can be used to determine the capacity of elite soccer players to perform intense intermittent exercise. Furthermore, the Yo-Yo IE2 test was shown to be a sensitive tool that not only relates to match performance but can also differentiate between intermittent exercise performance of players in various standards, stages of the season and playing positions.

  11. Academic self-concept, learning motivation, and test anxiety of the underestimated student.

    PubMed

    Urhahne, Detlef; Chao, Sheng-Han; Florineth, Maria Luise; Luttenberger, Silke; Paechter, Manuela

    2011-03-01

    BACKGROUND. Teachers' judgments of student performance on a standardized achievement test often result in an overestimation of students' abilities. In the majority of cases, a larger group of overestimated students and a smaller group of underestimated students are formed by these judgments. AIMS. In this research study, the consequences of the underestimation of students' mathematical performance potential were examined. SAMPLE. Two hundred and thirty-five fourth grade students and their fourteen mathematics teachers took part in the investigation. METHOD. Students worked on a standardized mathematics achievement test and completed a self-description questionnaire about motivation and affect. Teachers estimated each individual student's potential with regard to mathematics test performance as well as students' expectancy for success, level of aspiration, academic self-concept, learning motivation, and test anxiety. The differences between teachers' judgments on students' test performance and students' actual performance were used to build groups of underestimated and overestimated students. RESULTS. Underestimated students displayed equal levels of test performance, learning motivation, and level of aspiration in comparison with overestimated students, but had lower expectancy for success, lower academic self-concept, and experienced more test anxiety. Teachers expected that underestimated students would receive lower grades on the next mathematics test, believed that students were satisfied with lower grades, and assumed that the students have weaker learning motivation than their overestimated classmates. CONCLUSION. Teachers' judgment error was not confined to test performance but generalized to motivational and affective traits of the students. © 2010 The British Psychological Society.

  12. Quiet Clean Short-Haul Experimental Engine (QCSEE) Over-The-Wing (OTW) propulsion system test report. Volume 2: Aerodynamics and performance. [engine performance tests to define propulsion system performance on turbofan engines

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The design and testing of the over the wing engine, a high bypass, geared turbofan engine, are discussed. The propulsion system performance is examined for uninstalled performance and installed performance. The fan aerodynamic performance and the D nozzle and reverser thrust performance are evaluated.

  13. Occupational Survey Report, Cardiopulmonary Laboratory, AFSC 4H0X1, OSSN: 2541

    DTIC Science & Technology

    2004-02-01

    patients within facility 97 E0211 Set up humidifiers 97 E0175 Instruct patients in use of incentive spirometers 97 A0031 Obtain sputum samples 97 A0026...D0137 Calibrate pulmonary function testing equipment 100 D0150 Perform routine spirometry tests 100 D0146 Perform lung diffusion tests 100 A0042 Perform...consultations, or procedures 31 D0150 Perform routine spirometry tests 23 35 TABLE A2 REPRESENTATIVE TASKS PERFORMED BY MEMBERS IN THE SUPERVISION AND

  14. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Performance Verification Report: Final Comprehensive Performance Test Report, P/N 1331720-2TST, S/N 105/A1

    NASA Technical Reports Server (NTRS)

    Platt, R.

    1999-01-01

    This is the Performance Verification Report, Final Comprehensive Performance Test (CPT) Report, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A). This specification establishes the requirements for the CPT and Limited Performance Test (LPT) of the AMSU-1A, referred to here in as the unit. The sequence in which the several phases of this test procedure shall take place is shown.

  15. Perceptions and performance using computer-based testing: One institution's experience.

    PubMed

    Bloom, Timothy J; Rich, Wesley D; Olson, Stephanie M; Adams, Michael L

    2018-02-01

    The purpose of this study was to evaluate student and faculty perceptions of the transition to a required computer-based testing format and to identify any impact of this transition on student exam performance. Separate questionnaires sent to students and faculty asked about perceptions of and problems with computer-based testing. Exam results from program-required courses for two years prior to and two years following the adoption of computer-based testing were compared to determine if this testing format impacted student performance. Responses to Likert-type questions about perceived ease of use showed no difference between students with one and three semesters experience with computer-based testing. Of 223 student-reported problems, 23% related to faculty training with the testing software. Students most commonly reported improved feedback (46% of responses) and ease of exam-taking (17% of responses) as benefits to computer-based testing. Faculty-reported difficulties were most commonly related to problems with student computers during an exam (38% of responses) while the most commonly identified benefit was collecting assessment data (32% of responses). Neither faculty nor students perceived an impact on exam performance due to computer-based testing. An analysis of exam grades confirmed there was no consistent performance difference between the paper and computer-based formats. Both faculty and students rapidly adapted to using computer-based testing. There was no evidence that switching to computer-based testing had any impact on student exam performance. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. System performance testing of the DSN radio science system, Mark 3-78

    NASA Technical Reports Server (NTRS)

    Berman, A. L.; Mehta, J. S.

    1978-01-01

    System performance tests are required to evaluate system performance following initial system implementation and subsequent modification, and to validate system performance prior to actual operational usage. Non-real-time end-to-end Radio Science system performance tests are described that are based on the comparison of open-loop radio science data to equivalent closed-loop radio metric data, as well as an abbreviated Radio Science real-time system performance test that validates critical Radio Science System elements at the Deep Space Station prior to actual operational usage.

  17. Order of Administration of Math and Verbal Tests: An Ecological Intervention to Reduce Stereotype Threat on Girls' Math Performance

    ERIC Educational Resources Information Center

    Smeding, Annique; Dumas, Florence; Loose, Florence; Régner, Isabelle

    2013-01-01

    In 2 field experiments, we relied on the very features of real testing situations--where both math and verbal tests are administered--to examine whether order of test administration can, by itself, create vs. alleviate stereotype threat (ST) effects on girls' math performance. We predicted that taking the math test before the verbal test would be…

  18. Analyses of the dynamic docking test system for advanced mission docking system test programs. [Apollo Soyuz Test Project

    NASA Technical Reports Server (NTRS)

    Gates, R. M.; Williams, J. E.

    1974-01-01

    Results are given of analytical studies performed in support of the design, implementation, checkout and use of NASA's dynamic docking test system (DDTS). Included are analyses of simulator components, a list of detailed operational test procedures, a summary of simulator performance, and an analysis and comparison of docking dynamics and loads obtained by test and analysis.

  19. Indoor test for thermal performance evaluation of Libbey-Owens-Ford solar collector. [using a solar simulator

    NASA Technical Reports Server (NTRS)

    Shih, K.

    1977-01-01

    The thermal performance of a flat plate solar collector that uses liquid as the heat transfer medium was investigated under simulated conditions. The test conditions and thermal performance data obtained during the tests are presented in tabular form, as well as in graphs. Data obtained from a time constant test and incident angle modifier test, conducted to determine transient effect and the incident angle effect on the collector, are included.

  20. Supersonic Particle Impact Test Capabilities: Investigative Report

    NASA Technical Reports Server (NTRS)

    Rosales, Keisa

    2007-01-01

    NASA Johnson Space Center White Sands Test Facility (WSTF) performed particle impact flow tests to determine the maximum capabilities of the particle impact test systems in different configurations. Additional flow tests were performed to determine the target pressures at given upstream conditions to supplement the WSTF data located in ASTM Manual 36 (2000).

  1. Student Assessment System. Domain Referenced Tests. Allied Health Occupations/Practical Nursing. Volume 1: Skills.

    ERIC Educational Resources Information Center

    Simpson, Bruce; And Others

    These performance tests for the area of allied health occupations/practical nursing consist of a sampling technique (domain referenced tests) which covers all the possible performance situations. When used in total, they may also serve as a comprehensive test. Introductory materials discuss domain referenced testing, determining the domains, and…

  2. Educating Consumers in Self-Testing: The Development of an Online Decision Aid

    ERIC Educational Resources Information Center

    Ickenroth, Martine H. P.; Grispen, Janaica E. J.; Ronda, Gaby; Dinant, Geert-Jan; de Vries, Nanne K.; van der Weijden, Trudy

    2015-01-01

    Context and objective: Diagnostic self-tests have become available worldwide. The most frequently performed self-tests in the Netherlands are tests to detect high cholesterol and diabetes. Since these tests can be performed without professional guidance, potential consumers need to receive independent information on the pros and cons of…

  3. Automotive Stirling Engine Development Program

    NASA Technical Reports Server (NTRS)

    Nightingale, N.; Ernst, W.; Richey, A.; Simetkosky, M.; Antonelli, M. (Editor)

    1982-01-01

    Activities performed on Mod I engine testing and test results; the manufacture, assembly, and test of a Mod I engine in the United States; design initiation of the Mod I-A engine system; transient performance testing; Stirling reference engine manufacturing and reduced size studies; components and subsystems; and the study and test of low cost alloys are summarized.

  4. Business Telephone Etiquette. Comptetency Test Package. Office Occupations. Instructor's Guide.

    ERIC Educational Resources Information Center

    Hines, Donna

    This competency test package, one of a series of test packages for office occupations education, contains a list of performance objectives: a sample, 50-point objective test; and several performance test activities. The package also includes complete directions for the student and the instructor, plus answer keys and a guide for evaluating the…

  5. 46 CFR 164.023-11 - Acceptance tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 6 2014-10-01 2014-10-01 false Acceptance tests. 164.023-11 Section 164.023-11 Shipping...: SPECIFICATIONS AND APPROVAL MATERIALS Thread for Personal Flotation Devices § 164.023-11 Acceptance tests. (a) Performance testing. Manufacturers shall ensure that the performance tests described in § 164.023-7 (a) or (b...

  6. Development of a full-scale transmission testing procedure to evaluate advanced lubricants

    NASA Technical Reports Server (NTRS)

    Lewicki, David G.; Decker, Harry J.; Shimski, John T.

    1992-01-01

    Experimental tests were performed on the OH-58A helicopter main rotor transmission in the NASA Lewis 500-hp Helicopter Transmission Test Stand. The testing was part of a joint Navy/NASA/Army lubrication program. The objective of the program was to develop a separate lubricant for gearboxes and demonstrate an improved performance in life and load-carrying capacity. The goal of the experiments was to develop a testing procedure to fail certain transmission components using a MIL-L-23699 base reference oil, then run identical tests with improved lubricants and demonstrate performance. The tests were directed at failing components that the Navy has had problems with due to marginal lubrication. These failures included mast shaft bearing micropitting, sun gear and planet bearing fatigue, and spiral bevel gear scoring. A variety of tests were performed and over 900 hours of total run time accumulated for these tests. Some success was achieved in developing a testing procedure to produce sun gear and planet bearing fatigue failures. Only marginal success was achieved in producing mast shaft bearing micropitting and spiral bevel gear scoring.

  7. Scale factor and noise performance tests of the Bendix Corporation Rate Gyro Assembly (RGA)

    NASA Astrophysics Data System (ADS)

    Kim, R.; Hoffman, J.

    1980-08-01

    Three Bendix Corporation gyroscopes in a Rate Gyro Assembly (RGA) were tested at the Central Inertial Guidance Test Facility (CIGTF), 6585th Test Group, Holloman Air Force Base, New Mexico, from 29 May through 19 June 1980, for the National Aeronautics and Space Administration (NASA), Marshall Space Flight Center (MSFC), Huntsville, Alabama. The purpose of the tests was to characterize the noise performance of each gyro in the RGA in the frequency range of 0.01 hertz to 20 hertz. Gyro noise performance was then compared with seismic activity and previous results from Bendix Corporation testing. Eight-point tests were performed to obtain scale factors which were used to scale the Power Spectral Density (PSD) data. The PSD test series consisted of 1, 2.5, 5, 40 and 180 minute tests under various operating conditions (wheels on and off, low and high rate modes, and horizontal and vertical output axis orientations). The data are presented as PSD plots in the frequency domain. These results show a negligible seismic contribution and are comparable with data obtained at the Bendix test facility.

  8. Deep flaws in weldments of aluminum and titanium

    NASA Technical Reports Server (NTRS)

    Masters, J. N.; Engstrom, W. L.; Bixler, W. D.

    1974-01-01

    Surface flawed specimens of 2219-T87 and 6Al-4V STA titanium weldments were tested to determine static failure modes, failure strength, and fatigue flaw growth characteristics. Thicknesses selected for this study were purposely set at values where, for most test conditions, abrupt instability of the flaw at fracture would not be expected. Static tests for the aluminum weldments were performed at room, LN2 and LH2 temperatures. Titanium static tests for tests were performed at room and LH2 temperatures. Results of the static tests were used to plot curves relating initial flaw size to leakage- or failure-stresses (i.e. "failure" locus curves). Cyclic tests, for both materials, were then performed at room temperature, using initial flaws only slightly below the previously established failure locus for typical proof stress levels. Cyclic testing was performed on pairs of specimens, one with and one without a simulated proof test cycle. Comparisons were made then to determine the value and effect of proof testing as affected by the various variables of proof and operating stress, flaw shape, material thickness, and alloy.

  9. NEXT Single String Integration Test Results

    NASA Technical Reports Server (NTRS)

    Soulas, George C.; Patterson, Michael J.; Pinero, Luis; Herman, Daniel A.; Snyder, Steven John

    2010-01-01

    As a critical part of NASA's Evolutionary Xenon Thruster (NEXT) test validation process, a single string integration test was performed on the NEXT ion propulsion system. The objectives of this test were to verify that an integrated system of major NEXT ion propulsion system elements meets project requirements, to demonstrate that the integrated system is functional across the entire power processor and xenon propellant management system input ranges, and to demonstrate to potential users that the NEXT propulsion system is ready for transition to flight. Propulsion system elements included in this system integration test were an engineering model ion thruster, an engineering model propellant management system, an engineering model power processor unit, and a digital control interface unit simulator that acted as a test console. Project requirements that were verified during this system integration test included individual element requirements ; integrated system requirements, and fault handling. This paper will present the results of these tests, which include: integrated ion propulsion system demonstrations of performance, functionality and fault handling; a thruster re-performance acceptance test to establish baseline performance: a risk-reduction PMS-thruster integration test: and propellant management system calibration checks.

  10. Relationships between field performance tests in high-level soccer players.

    PubMed

    Ingebrigtsen, Jørgen; Brochmann, Marit; Castagna, Carlo; Bradley, Paul S; Ade, Jack; Krustrup, Peter; Holtermann, Andreas

    2014-04-01

    To reduce athlete testing time, the aim of this study was to investigate the relationship between the Yo-Yo intermittent recovery test levels 1 (IR1) and 2 (IR2) performances, maximal sprinting speed (10, 20, and 35 m), repeated sprint ability (RSA; 7 × 35 m), and submaximal heart rates (HRs) after 2 and 4 minutes of the Yo-Yo IR tests by testing 57 high-level soccer players. All players played regularly in one of 3 highest levels of Norwegian soccer and were tested during 3 sessions on 3 consecutive days. Large correlations were observed between Yo-Yo IR1 and IR2 test performances (r = 0.753, p ≤ 0.05). Small and moderate correlations were found between 20- and 35-m sprinting speed and Yo-Yo IR1 performance (r = -0.289 and -0.321, respectively, p ≤ 0.05), whereas 35-m sprinting speed correlated moderately to Yo-Yo IR2 performance (r = -0.371, p ≤ 0.05). Repeated sprint ability at 10, 20, and 35 m all showed moderate to large correlations to Yo-Yo IR1 performance (r = -0.337 to -0.573, p ≤ 0.05). Repeated sprint ability at 20 m (r = -0.348, p ≤ 0.05) and 35 m (r = -0.552, p ≤ 0.01) correlated moderately and largely to Yo-Yo IR2 performance. In addition, moderate and large correlations were found between submaximal Yo-Yo IR1 HRs after 2 (r = -0.483, p ≤ 0.01) and 4 minutes (r = -0.655, p ≤ 0.01) and Yo-Yo IR1 performance, and 2 minutes Yo-Yo IR2 HR and Yo-Yo IR2 performance (r = -0.530, p ≤ 0.01). Intraclass correlation measures of submaximal HR after 2 and 4 minutes of Yo-Yo IR1 test and after 2 minutes of the Yo-Yo IR2 were 0.92 (coefficient of variation [CV] = 4.1%, n = 33), 0.93 (CV = 3.8%, n = 33), and 0.72 (CV = 2.9%, n = 10). Adjusted ordinary least square (OLS) regressions revealed associations (p ≤ 0.05) between sprint speed at 20 and 35 m and Yo-Yo IR1 test performance, but only between 35 m and IR2 test performance (p ≤ 0.05). Further, OLS showed that RSA at 35 m was related to both levels of the Yo-Yo IR test (p ≤ 0.01), and that submaximal HRs after 2 and 4 minutes were independently associated with Yo-Yo IR1 and IR2 performances (p ≤ 0.01). In conclusion, Yo-Yo IR1 and 2 test performances, as well as sprint and RSA performances, correlated very largely, and it may therefore be considered using only one of the Yo-Yo tests and a RSA test, in a general soccer-specific field test protocol. The submaximal HR measures during Yo-Yo tests are reproducible and may be used for frequent, time-efficient, and nonexhaustive testing of intermittent exercise capacity of high-level soccer players.

  11. 40 CFR 60.3035 - May I conduct performance testing less often?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Model Rule-Continuous Compliance Requirements § 60.3035 May I conduct performance testing less often? (a) You can test less often for a given pollutant if you have test data for at least three consecutive...

  12. Development, evaluation and application of performance-based brake testing technologies field test : executive summary

    DOT National Transportation Integrated Search

    1999-09-01

    This report presents the results of the field test portion of the Development, Evaluation, and Application of Performance-Based Brake Testing Technologies sponsored by the Federal Highway Administrations (FHWA) Office of Motor Carriers.

  13. Durability of hardboard siding

    Treesearch

    Anton TenWolde; Charles Carll

    2004-01-01

    In response to concerns about hardboard siding failures, a study was performed to assess if performance in a current hardboard industry quality assurance test procedure correlated with in-service performance and how well this performance might be predicted by use of alternative or additional test procedures. A variety of laboratory tests were performed on a large...

  14. Application of Background Oriented Schlieren for Altitude Testing of Rocket Engines

    NASA Technical Reports Server (NTRS)

    Wernet, Mark P.; Stiegemeier, Benjamin R.

    2017-01-01

    A series of experiments was performed to determine the feasibility of using the Background Oriented Schlieren, BOS, flow visualization technique to image a simulated, small, rocket engine, plume under altitude test conditions. Testing was performed at the NASA Glenn Research Centers Altitude Combustion Stand, ACS, using nitrogen as the exhaust gas simulant. Due to limited optical access to the facility test capsule, all of the hardware required to conduct the BOS were located inside the vacuum chamber. During the test series 26 runs were performed using two different nozzle configurations with pressures in the test capsule around 0.3 psia. No problems were encountered during the test series resulting from the optical hardware being located in the test capsule and acceptable resolution images were captured. The test campaign demonstrated the ability of using the BOS technique for small, rocket engine, plume flow visualization during altitude testing.

  15. ESGE-ESGENA technical specification for process validation and routine testing of endoscope reprocessing in washer-disinfectors according to EN ISO 15883, parts 1, 4, and ISO/TS 15883-5.

    PubMed

    Beilenhoff, Ulrike; Biering, Holger; Blum, Reinhard; Brljak, Jadranka; Cimbro, Monica; Dumonceau, Jean-Marc; Hassan, Cesare; Jung, Michael; Neumann, Christiane; Pietsch, Michael; Pineau, Lionel; Ponchon, Thierry; Rejchrt, Stanislav; Rey, Jean-François; Schmidt, Verona; Tillett, Jayne; van Hooft, Jeanin

    2017-12-01

    1 Prerequisites. The clinical service provider should obtain confirmation from the endoscope washer-disinfector (EWD) manufacturer that all endoscopes intended to be used can be reprocessed in the EWD. 2 Installation qualification. This can be performed by different parties but national guidelines should define who has the responsibilities, taking into account legal requirements. 3 Operational qualification. This should include parametric tests to verify that the EWD is working according to its specifications. 4 Performance qualification. Testing of cleaning performance, microbiological testing of routinely used endoscopes, and the quality of the final rinse water should be considered in all local guidelines. The extent of these tests depends on local requirements. According to the results of type testing performed during EWD development, other parameters can be tested if local regulatory authorities accept this. Chemical residues on endoscope surfaces should be searched for, if acceptable test methods are available. 5 Routine inspections. National guidelines should consider both technical and performance criteria. Individual risk analyses performed in the validation and requalification processes are helpful for defining appropriate test frequencies for routine inspections. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Predicting psychopharmacological drug effects on actual driving performance (SDLP) from psychometric tests measuring driving-related skills.

    PubMed

    Verster, Joris C; Roth, Thomas

    2012-03-01

    There are various methods to examine driving ability. Comparisons between these methods and their relationship with actual on-road driving is often not determined. The objective of this study was to determine whether laboratory tests measuring driving-related skills could adequately predict on-the-road driving performance during normal traffic. Ninety-six healthy volunteers performed a standardized on-the-road driving test. Subjects were instructed to drive with a constant speed and steady lateral position within the right traffic lane. Standard deviation of lateral position (SDLP), i.e., the weaving of the car, was determined. The subjects also performed a psychometric test battery including the DSST, Sternberg memory scanning test, a tracking test, and a divided attention test. Difference scores from placebo for parameters of the psychometric tests and SDLP were computed and correlated with each other. A stepwise linear regression analysis determined the predictive validity of the laboratory test battery to SDLP. Stepwise regression analyses revealed that the combination of five parameters, hard tracking, tracking and reaction time of the divided attention test, and reaction time and percentage of errors of the Sternberg memory scanning test, together had a predictive validity of 33.4%. The psychometric tests in this test battery showed insufficient predictive validity to replace the on-the-road driving test during normal traffic.

  17. Next-day effects of ramelteon (8 mg), zopiclone (7.5 mg), and placebo on highway driving performance, memory functioning, psychomotor performance, and mood in healthy adult subjects.

    PubMed

    Mets, Monique A J; de Vries, Juna M; de Senerpont Domis, Lieke M; Volkerts, Edmund R; Olivier, Berend; Verster, Joris C

    2011-10-01

    To evaluate the next-morning residual effects of ramelteon (8 mg), zopiclone (7.5 mg), and placebo on driving performance, memory functioning, psychomotor performance, and mood in healthy adult subjects following bedtime dosing and a middle of the night awakening. Single-center, randomized, double-blind, double-dummy, placebo-controlled, crossover study. Utrecht University, The Netherlands. 30 healthy volunteers (15 males and 15 females). a single dose of ramelteon (8 mg), zopiclone (7.5 mg), and placebo, administered at bedtime. A balance test was performed at night. Other tests were performed the following morning, 8.5 h after administration. Subjects performed a 100-km highway driving test in normal traffic. Primary outcome measure was the standard deviation of the lateral position (SDLP), i.e., the weaving of the car. After driving, cognitive, memory, and psychomotor tests were performed and mood was assessed. SDLP was significantly increased after the intake of ramelteon (+2.2 cm) and zopiclone (+2.9 cm). Ramelteon and zopiclone produced significant impairment on reaction time (P<0.024) in the Sternberg Memory Scanning Test, slow (P<0.007) and fast (P<0.010) tracking, reaction speed (P<0.015) and tracking (P<0.001) in the Divided Attention Test, and delayed recall (P<0.032) in the Word Learning Test. In contrast to ramelteon, zopiclone additionally impaired performance on the Digit Symbol Substitution Test (P<0.001) and the balance test (P<0.001). Ramelteon (8 mg) and zopiclone (7.5 mg) significantly impaired driving performance, cognitive, memory, and psychomotor performance the morning following bedtime administration. In contrast to zopiclone, ramelteon produced no balance impairments. CLINICAL TRIAL IDENTIFIER: NCT00319215 (www.clinicaltrials.gov).

  18. 40 CFR 63.7520 - What performance tests and procedures must I use?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... load while burning the type of fuel or mixture of fuels that have the highest content of chlorine... performance test. (e) You may not conduct performance tests during periods of startup, shutdown, or...

  19. 40 CFR 63.7520 - What performance tests and procedures must I use?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... load while burning the type of fuel or mixture of fuels that have the highest content of chlorine... performance test. (e) You may not conduct performance tests during periods of startup, shutdown, or...

  20. 40 CFR 63.7520 - What performance tests and procedures must I use?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... load while burning the type of fuel or mixture of fuels that have the highest content of chlorine... performance test. (e) You may not conduct performance tests during periods of startup, shutdown, or...

  1. Fighter pilots' heart rate, heart rate variation and performance during an instrument flight rules proficiency test.

    PubMed

    Mansikka, Heikki; Virtanen, Kai; Harris, Don; Simola, Petteri

    2016-09-01

    Increased task demand will increase the pilot mental workload (PMWL). When PMWL is increased, mental overload may occur resulting in degraded performance. During pilots' instrument flight rules (IFR) proficiency test, PMWL is typically not measured. Therefore, little is known about workload during the proficiency test and pilots' potential to cope with higher task demands than those experienced during the test. In this study, fighter pilots' performance and PMWL was measured during a real IFR proficiency test in an F/A-18 simulator. PMWL was measured using heart rate (HR) and heart rate variation (HRV). Performance was rated using Finnish Air Force's official rating scales. Results indicated that HR and HRV differentiate varying task demands in situations where variations in performance are insignificant. It was concluded that during a proficiency test, PMWL should be measured together with the task performance measurement. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Cognitive Determinants of Academic Performance in Nigerian Pharmacy Schools.

    PubMed

    Ubaka, Chukwuemeka M; Sansgiry, Sujit S; Ukwe, Chinwe V

    2015-09-25

    Objective. To evaluate cognitive factors that might influence academic performance of students in Nigerian pharmacy schools. Methods. A cross-sectional, multi-center survey of Nigerian pharmacy students from 7 schools of pharmacy was conducted using 2 validated questionnaires measuring cognitive constructs such as test anxiety, academic competence, test competence, time management, and strategic study habits. Results. Female students and older students scored significantly better on time management skills and study habits, respectively. Test anxiety was negatively associated with academic performance while test competence, academic competence, and time management were positively associated with academic performance. These 4 constructs significantly discriminated between the lower and higher performing students, with the first 2 contributing to the most differences. Conclusion. Test and academic competence, test anxiety, and time management were significant factors associated with low and high academic performance among Nigerian pharmacy students. The study also demonstrated the significant effects of age, gender, and marital status on these constructs.

  3. Cognitive Determinants of Academic Performance in Nigerian Pharmacy Schools

    PubMed Central

    Sansgiry, Sujit S.; Ukwe, Chinwe V.

    2015-01-01

    Objective. To evaluate cognitive factors that might influence academic performance of students in Nigerian pharmacy schools. Methods. A cross-sectional, multi-center survey of Nigerian pharmacy students from 7 schools of pharmacy was conducted using 2 validated questionnaires measuring cognitive constructs such as test anxiety, academic competence, test competence, time management, and strategic study habits. Results. Female students and older students scored significantly better on time management skills and study habits, respectively. Test anxiety was negatively associated with academic performance while test competence, academic competence, and time management were positively associated with academic performance. These 4 constructs significantly discriminated between the lower and higher performing students, with the first 2 contributing to the most differences. Conclusion. Test and academic competence, test anxiety, and time management were significant factors associated with low and high academic performance among Nigerian pharmacy students. The study also demonstrated the significant effects of age, gender, and marital status on these constructs. PMID:27168614

  4. Space Suit Portable Life Support System (PLSS) 2.0 Human-in-the-Loop (HITL) Testing

    NASA Technical Reports Server (NTRS)

    Watts, Carly; Vogel, Matthew

    2016-01-01

    The space suit Portable Life Support System (PLSS) 2.0 represents the second integrated prototype developed and tested to mature a design that uses advanced technologies to reduce consumables, improve robustness, and provide additional capabilities over the current state of the art. PLSS 2.0 was developed in 2012, with extensive functional evaluations and system performance testing through mid-2014. In late 2014, PLSS 2.0 was integrated with the Mark III space suit in an ambient laboratory environment to facilitate manned testing, designated PLSS 2.0 Human-in-the-Loop (HITL) testing, in which the PLSS prototype performed the primary life support functions, including suit pressure regulation, ventilation, carbon dioxide control, and cooling of the test subject and PLSS avionics. The intent of this testing was to obtain subjective test subject feedback regarding qualitative aspects of PLSS 2.0 performance such as thermal comfort, sounds, smells, and suit pressure fluctuations due to the cycling carbon dioxide removal system, as well as to collect PLSS performance data over a range of human metabolic rates from 500-3000 Btu/hr. Between October 27 and December 18, 2014, nineteen two-hour simulated EVA test points were conducted in which suited test subjects walked on a treadmill to achieve a target metabolic rate. Six test subjects simulated nominal and emergency EVA conditions with varied test parameters including metabolic rate profile, carbon dioxide removal control mode, cooling water temperature, and Liquid Cooling and Ventilation Garment (state of the art or prototype). The nineteen test points achieved more than 60 hours of test time, with 36 hours accounting for simulated EVA time. The PLSS 2.0 test article performed nominally throughout the test series, confirming design intentions for the advanced PLSS. Test subjects' subjective feedback provided valuable insight into thermal comfort and perceptions of suit pressure fluctuations that will influence future advanced PLSS design and testing strategies.

  5. Space Suit Portable Life Support System (PLSS) 2.0 Pre-Installation Acceptance (PIA) Testing

    NASA Technical Reports Server (NTRS)

    Watts, Carly; Vogel, Matthew

    2016-01-01

    Following successful completion of the space suit Portable Life Support System (PLSS) 1.0 development and testing in 2011, the second system-level prototype, PLSS 2.0, was developed in 2012 to continue the maturation of the advanced PLSS design which is intended to reduce consumables, improve reliability and robustness, and incorporate additional sensing and functional capabilities over the current Space Shuttle/International Space Station Extravehicular Mobility Unit (EMU) PLSS. PLSS 2.0 represents the first attempt at a packaged design comprising first generation or later component prototypes and medium fidelity interfaces within a flight-like representative volume. Pre-Installation Acceptance (PIA) is carryover terminology from the Space Shuttle Program referring to the series of test sequences used to verify functionality of the EMU PLSS prior to installation into the Space Shuttle airlock for launch. As applied to the PLSS 2.0 development and testing effort, PIA testing designated the series of 27 independent test sequences devised to verify component and subsystem functionality, perform in situ instrument calibrations, generate mapping data to define set-points for control algorithms, evaluate hardware performance against advanced PLSS design requirements, and provide quantitative and qualitative feedback on evolving design requirements and performance specifications. PLSS 2.0 PIA testing was carried out from 3/20/13 - 3/15/14 using a variety of test configurations to perform test sequences that ranged from stand-alone component testing to system-level testing, with evaluations becoming increasingly integrated as the test series progressed. Each of the 27 test sequences was vetted independently, with verification of basic functionality required before completion. Because PLSS 2.0 design requirements were evolving concurrently with PLSS 2.0 PIA testing, the requirements were used as guidelines to assess performance during the tests; after the completion of PIA testing, test data served to improve the fidelity and maturity of design requirements as well as plans for future advanced PLSS functional testing.

  6. Space Suit Portable Life Support System (PLSS) 2.0 Pre-Installation Acceptance (PIA) Testing

    NASA Technical Reports Server (NTRS)

    Anchondo, Ian; Cox, Marlon; Meginnis, Carly; Westheimer, David; Vogel, Matt R.

    2016-01-01

    Following successful completion of the space suit Portable Life Support System (PLSS) 1.0 development and testing in 2011, the second system-level prototype, PLSS 2.0, was developed in 2012 to continue the maturation of the advanced PLSS design. This advanced PLSS is intended to reduce consumables, improve reliability and robustness, and incorporate additional sensing and functional capabilities over the current Space Shuttle/International Space Station Extravehicular Mobility Unit (EMU) PLSS. PLSS 2.0 represents the first attempt at a packaged design comprising first generation or later component prototypes and medium fidelity interfaces within a flight-like representative volume. Pre-Installation Acceptance (PIA) is carryover terminology from the Space Shuttle Program referring to the series of test sequences used to verify functionality of the EMU PLSS prior to installation into the Space Shuttle airlock for launch. As applied to the PLSS 2.0 development and testing effort, PIA testing designated the series of 27 independent test sequences devised to verify component and subsystem functionality, perform in situ instrument calibrations, generate mapping data, define set-points, evaluate control algorithms, evaluate hardware performance against advanced PLSS design requirements, and provide quantitative and qualitative feedback on evolving design requirements and performance specifications. PLSS 2.0 PIA testing was carried out in 2013 and 2014 using a variety of test configurations to perform test sequences that ranged from stand-alone component testing to system-level testing, with evaluations becoming increasingly integrated as the test series progressed. Each of the 27 test sequences was vetted independently, with verification of basic functionality required before completion. Because PLSS 2.0 design requirements were evolving concurrently with PLSS 2.0 PIA testing, the requirements were used as guidelines to assess performance during the tests; after the completion of PIA testing, test data served to improve the fidelity and maturity of design requirements as well as plans for future advanced PLSS functional testing.

  7. Measuring more than we know? An examination of the motivational and situational influences in science achievement

    NASA Astrophysics Data System (ADS)

    Haydel, Angela Michelle

    The purpose of this dissertation was to advance theoretical understanding about fit between the personal resources of individuals and the characteristics of science achievement tasks. Testing continues to be pervasive in schools, yet we know little about how students perceive tests and what they think and feel while they are actually working on test items. This study focused on both the personal (cognitive and motivational) and situational factors that may contribute to individual differences in achievement-related outcomes. 387 eighth grade students first completed a survey including measures of science achievement goals, capability beliefs, efficacy related to multiple-choice items and performance assessments, validity beliefs about multiple-choice items and performance assessments, and other perceptions of these item formats. Students then completed science achievement tests including multiple-choice items and two performance assessments. A sample of students was asked to verbalize both thoughts and feelings as they worked through the test items. These think-alouds were transcribed and coded for evidence of cognitive, metacognitive and motivational engagement. Following each test, all students completed measures of effort, mood, energy level and strategy use during testing. Students reported that performance assessments were more challenging, authentic, interesting and valid than multiple-choice tests. They also believed that comparisons between students were easier using multiple-choice items. Overall, students tried harder, felt better, had higher levels of energy and used more strategies while working on performance assessments. Findings suggested that performance assessments might be more congruent with a mastery achievement goal orientation, while multiple-choice tests might be more congruent with a performance achievement goal orientation. A variable-centered analytic approach including regression analyses provided information about how students, on average, who differed in terms of their teachers' ratings of their science ability, achievement goals, capability beliefs and experiences with science achievement tasks perceived, engaged in, and performed on multiple-choice items and performance assessments. Person-centered analyses provided information about the perceptions, engagement and performance of subgroups of individuals who had different motivational characteristics. Generally, students' personal goals and capability beliefs related more strongly to test perceptions, but not performance, while teacher ratings of ability and test-specific beliefs related to performance.

  8. Performance-oriented packaging testing of PPP-B-601 ERAPS wood box for packing Group II solid hazardous material. Test report for Oct 91

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, E.

    1991-10-01

    Qualification tests were performed to determine whether the in-service PPP-B-601 ERAPS Wood Box could be utilized to contain properly dunnaged solid type hazardous materials weighing up to a gross weight of 237 kg (523 pounds). The tests were conducted in accordance with Performance Oriented Packaging (POP) requirements specified by the United Nations Recommendations on the Transportation of Dangerous Goods. The box has conformed to the POP performance requirements; i.e., the box successfully retained its contents throughout the stacking, vibration and drop tests.

  9. On the road performance tests of electric test vehicle for correlation with road load simulator

    NASA Technical Reports Server (NTRS)

    Dustin, M. O.; Slavik, R. J.

    1982-01-01

    A dynamometer (road load simulator) is used to test and evaluate electric vehicle propulsion systems. To improve correlation between system tests on the road load simulator and on the road, similar performance tests are conducted using the same vehicle. The results of track tests on the electric propulsion system test vehicle are described. The tests include range at constant speeds and over SAE J227a driving cycles, maximum accelerations, maximum gradability, and tire rolling resistance determination. Road power requirements and energy consumption were also determined from coast down tests.

  10. 40 CFR Appendix 1 to Part 3 - Priority Reports

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...). Hazardous Air Pollutants Compliance Report Reports containing results from performance test, opacity tests, and visible emissions tests. Progress reports; periodic and immediate startup, shutdown, and... Owners report emissions data from stationary sources 51.211. Report For Initial Performance Test Report...

  11. 40 CFR Appendix 1 to Part 3 - Priority Reports

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...). Hazardous Air Pollutants Compliance Report Reports containing results from performance test, opacity tests, and visible emissions tests. Progress reports; periodic and immediate startup, shutdown, and... Owners report emissions data from stationary sources 51.211. Report For Initial Performance Test Report...

  12. NCCS Regression Test Harness

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tharrington, Arnold N.

    2015-09-09

    The NCCS Regression Test Harness is a software package that provides a framework to perform regression and acceptance testing on NCCS High Performance Computers. The package is written in Python and has only the dependency of a Subversion repository to store the regression tests.

  13. Space Station Freedom Environmental Control and Life Support System (ECLSS) phase 3 simplified integrated test trace contaminant control subsystem performance

    NASA Technical Reports Server (NTRS)

    Perry, J. L.

    1990-01-01

    Space Station Freedom environmental control and life support system testing has been conducted at Marshall Space Flight Center since 1986. The phase 3 simplified integrated test (SIT) conducted from July 30, 1989, through August 11, 1989, tested an integrated air revitalization system. During this test, the trace contaminant control subsystem (TCCS) was directly integrated with the bleed stream from the carbon dioxide reduction subsystem. The TCCS performed as expected with minor anomalies. The test set the basis for further characterizing the TCCS performance as part of advance air revitalization system configurations.

  14. Correction of Pressure Drop in Steam and Water System in Performance Test of Boiler

    NASA Astrophysics Data System (ADS)

    Liu, Jinglong; Zhao, Xianqiao; Hou, Fanjun; Wu, Xiaowu; Wang, Feng; Hu, Zhihong; Yang, Xinsen

    2018-01-01

    Steam and water pressure drop is one of the most important characteristics in the boiler performance test. As the measuring points are not in the guaranteed position and the test condition fluctuation exsits, the pressure drop test of steam and water system has the deviation of measuring point position and the deviation of test running parameter. In order to get accurate pressure drop of steam and water system, the corresponding correction should be carried out. This paper introduces the correction method of steam and water pressure drop in boiler performance test.

  15. Use of proficiency test performance to determine clinical laboratory director qualifications.

    PubMed

    Howanitz, P J

    1988-04-01

    Many activities and policies influence laboratory test quality. Proficiency test results are one measure of laboratory quality, and during the past 25 years, five studies have examined the relationship of laboratory director educational requirements to proficiency test results. Data from three studies support the association between director qualifications and quality as measured by proficiency test performance, whereas no relationship was found in the other two studies. Possible reasons for conflicting results include differences in database size and demographics; in addition, proficiency test results may be inappropriate, although widely used, as the sole measure of laboratory director performance.

  16. Simulating the Impact Response of Three Full-Scale Crash Tests of Cessna 172 Aircraft

    NASA Technical Reports Server (NTRS)

    Jackson, Karen E.; Fasanella, Edwin L.; Littell, Justin D.; Annett, Martin S.; Stimson, Chad M.

    2017-01-01

    During the summer of 2015, a series of three full-scale crash tests were performed at the Landing and Impact Research Facility located at NASA Langley Research Center of Cessna 172 aircraft. The first test (Test 1) represented a flare-to-stall emergency or hard landing onto a rigid surface. The second test (Test 2) represented a controlled-flight- into-terrain (CFIT) with a nose down pitch attitude of the aircraft, which impacted onto soft soil. The third test (Test 3) also represented a CFIT with a nose up pitch attitude of the aircraft, which resulted in a tail strike condition. Test 3 was also conducted onto soft soil. These crash tests were performed for the purpose of evaluating the performance of Emergency Locator Transmitters and to generate impact test data for model calibration. Finite element models were generated and impact analyses were conducted to simulate the three impact conditions using the commercial nonlinear, transient dynamic finite element code, LS-DYNA®. The objective of this paper is to summarize test-analysis results for the three full-scale crash tests.

  17. Atopy patch test reactions to house dust mites in patients with scabies.

    PubMed

    Taşkapan, Oktay; Harmanyeri, Yavuz

    2005-01-01

    It is well known that the house dust and the scabies mites are related phylogenetically. We therefore performed atopy patch tests with house dust mite antigens (Dermatophagoides pteronyssinus (Dp) and/or Dermatophagoides farinae (Df)) in scabies patients without atopy and healthy controls. We studied 25 men with active scabies and 25 healthy controls. Skin prick tests with standardized house dust mite extract were performed for all patients and controls. An intradermal test procedure was carried out in skin prick test-negative patients, and for controls showing positive atopy patch test to Dp and/or Df. While atopy patch tests were performed directly in all healthy controls, patients with scabies were first treated and on the next day, atopy patch tests were performed. Twenty-two of 25 patients with scabies (88%) had skin prick test and/or intradermal test positivity against house dust mites, whereas 17/25 patients (68%) had atopy patch test positivity against house dust mites (Dp and/or Df). There was no statistically significant difference between skin prick test and/or intradermal test positivity and atopy patch test positivity in a regression analysis (p=0.222). The only statistically significant correlation was between atopy patch test positivity and the extent of scabies involvement (p<0.05). Only few of the healthy controls had positive tests. In this study, we have shown that a positive atopy patch test to house dust mite antigens is not specific for patients with atopic dermatitis, but also occurs in scabies patients without a history of atopic dermatitis.

  18. Motivation and experiences of self-testers regarding tests for cardiovascular risk factors.

    PubMed

    Ickenroth, Martine H P; Grispen, Janaica E J; Ronda, Gaby; Tacken, Marloes; Dinant, Geert-Jan; de Vries, Nanne K; van der Weijden, Trudy

    2014-02-01

    In recent years, self-tests have become increasingly available to the general public, though their value is still being debated. Because these tests are available, consumers should have access to clear information about self-testing. Examining experiences of self-testers could contribute to the development of consumer information. Detailed exploration of consumers' experiences with self-testing for cardiovascular risk factors. Semi-structured interviews with 20 consumers who had performed a self-test for glucose, cholesterol or albuminuria. The main topics of the interviews were reasons for self-testing, performing the self-test, follow-up behaviour and perceived need for information on self-testing. Data were analysed using thematic content analysis. Regarding the reason for self-testing, three types of users were distinguished: those who engaged in self-testing when a test was offered, either with or without previous knowledge about the disease or risk factor, and those who had actively decided to test and had searched for a self-test themselves. Self-testers had generally experienced no problems performing the test or interpreting the result and had considerable confidence in the result. They were easily reassured by a normal result, while an abnormal result did not automatically mean they consulted a doctor. Most participants did not feel the need for more information. Self-testers often perform tests for reassurance, without considering the disadvantages, such as the absence of professional counselling and the risk of false-positive or false-negative results. Consumer information should promote more informed and deliberate choices for self-testing. © 2011 John Wiley & Sons Ltd.

  19. Proposed acceptance, qualification, and characterization tests for thin-film PV modules

    NASA Technical Reports Server (NTRS)

    Waddington, D.; Mrig, L.; Deblasio, R.; Ross, R.

    1988-01-01

    Details of a proposed test program for PV thin-film modules which the Department of Energy has directed the Solar Energy Research Institute (SERI) to prepare are presented. Results of one of the characterization tests that SERI has performed are also presented. The objective is to establish a common approach to testing modules that will be acceptable to both users and manufacturers. The tests include acceptance, qualification, and characterization tests. Acceptance tests verify that randomly selected modules have similar characteristics. Qualification tests are based on accelerated test methods designed to simulate adverse conditions. Characterization tests provide data on performance in a predefined environment.

  20. Hardware test program for evaluation of baseline range/range rate sensor concept

    NASA Technical Reports Server (NTRS)

    Pernic, E.

    1985-01-01

    The test program Phase II effort provides additional design information in terms of range and range rate (R/R) sensor performance when observing and tracking a typical spacecraft target. The target used in the test program was a one-third scale model of the Hubble Space Telescope (HST) available at the MSFC test site where the tests were performed. A modified Bendix millimeter wave radar served as the R/R sensor test bed for evaluation of range and range rate tracking performance, and generation of radar signature characteristics of the spacecraft target. A summary of program test results and conclusions are presented along with detailed description of the Bendix test bed radar with accompaning instrumentation. The MSFC test site and facilities are described. The test procedures used to establish background levels, and the calibration procedures used in the range accuracy tests and RCS (radar cross section) signature measurements, are presented and a condensed version of the daily log kept during the 5 September through 17 September test period is also presented. The test program results are given starting with the RCS signature measurements, then continuing with range measurement accuracy test results and finally the range and range rate tracking accuracy test results.

  1. The pattern and technique in the clinical evaluation of the adult hip: the common physical examination tests of hip specialists.

    PubMed

    Martin, Hal D; Kelly, Bryan T; Leunig, Michael; Philippon, Marc J; Clohisy, John C; Martin, RobRoy L; Sekiya, Jon K; Pietrobon, Ricardo; Mohtadi, Nicholas G; Sampson, Thomas G; Safran, Marc R

    2010-02-01

    The purpose of this study was to systematically evaluate the technique and tests used in the physical examination of the adult hip performed by multiple clinicians who regularly treat patients with hip problems and identify common physical examination patterns. The subjects included 5 men and 6 women with a mean age (+/-SD) of 29.8 +/- 9.4 years. They underwent physical examination of the hip by 6 hip specialists with a strong interest in hip-related problems. All examiners were blind to patient radiographs and diagnoses. Patient examinations were video recorded and reviewed. It was determined that 18 tests were most frequently performed (>or=40%) by the examiners, 3 standing, 11 supine, 3 lateral, and 1 prone. Of the most frequently performed tests, 10 were performed more than 50% of the time. The tests performed in the supine position were as follows: flexion range of motion (ROM) (percentage of use, 98%), flexion internal rotation ROM (98%), flexion external rotation ROM (86%), passive supine rotation test (76%), flexion/adduction/internal rotation test (70%), straight leg raise against resistance test (61%), and flexion/abduction/external rotation test (52%). The tests performed in the standing position were the gait test (86%) and the single-leg stance phase test (77%). The 1 test in the prone position was the femoral anteversion test (58%). There are variations in the testing that hip specialists perform to examine and evaluate their patients, but there is enough commonality to form the basis to recommend a battery of physical examination maneuvers that should be considered for use in evaluating the hip. Patients presenting with groin, abdominal, back, and/or hip pain need to have a basic examination to ensure that the hip is not overlooked. A comprehensive physical examination of the hip will benefit the patient and the physician and serve as the foundation for future multicenter clinical studies. (c) 2010 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  2. Performance Evaluation Test of the Rapid Area Preparation Tool (RAPTOR)

    DTIC Science & Technology

    2008-12-01

    the standard SETCO tires. A blast test of the new SETCO tire is scheduled for the spring of...Washington, DC 20301-2500 Performance Evaluation Test of the Rapid Area Preparation Tool (RAPTOR) December 2008 Prepared ...2008 to 00-00-2008 4. TITLE AND SUBTITLE Performance Evaluation Test of the Rapid Area Preparation Tool (RAPTOR) 5a. CONTRACT NUMBER 5b.

  3. Investigating the Validity of an Integrated Listening-Speaking Task: A Discourse-Based Analysis of Test Takers' Oral Performances

    ERIC Educational Resources Information Center

    Frost, Kellie; Elder, Catherine; Wigglesworth, Gillian

    2012-01-01

    Performance on integrated tasks requires candidates to engage skills and strategies beyond language proficiency alone, in ways that can be difficult to define and measure for testing purposes. While it has been widely recognized that stimulus materials impact test performance, our understanding of the way in which test takers make use of these…

  4. Research of laser stealth performance test technology

    NASA Astrophysics Data System (ADS)

    Chen, Zhen-xing; Shi, Sheng-bing; Han, Fu-li; Wu, Yan-lin; Song, Chun-yan

    2014-09-01

    Laser stealth is an important way of photoelectric stealth weapons systems. According to operational principle of laser range finder, we actively explore and study the stealth performance approval testing technology of laser stealth materials, and bring forward and establish the stealth performance field test methods of stealth efficiency evaluation. Through contrastive test of two kinds of materials, the method is correct and effective.

  5. New method for rapid testing of bond strength for wood adhesives

    Treesearch

    James M. Wescott; Michael J. Birkeland; Amy E. Traska; Charles R. Frihart; Brice N. Dally

    2007-01-01

    In developing new adhesives for wood bonding, the testing of bond performance can often be a limiting factor in the development process. Evaluating the bond performance of an adhesive that can be prepared in less than a day often takes several days using standard performance tests. This testing slows the development process and may cause a company to abandon a...

  6. Validity, Reliability, and Sensitivity of a Volleyball Intermittent Endurance Test.

    PubMed

    Rodríguez-Marroyo, Jose A; Medina-Carrillo, Javier; García-López, Juan; Morante, Juan C; Villa, José G; Foster, Carl

    2017-03-01

    To analyze the concurrent and construct validity of a volleyball intermittent endurance test (VIET). The VIET's test-retest reliability and sensitivity to assess seasonal changes was also studied. During the preseason, 71 volleyball players of different competitive levels took part in this study. All performed the VIET and a graded treadmill test with gas-exchange measurement (GXT). Thirty-one of the players performed an additional VIET to analyze the test-retest reliability. To test the VIET's sensitivity, 28 players repeated the VIET and GXT at the end of their season. Significant (P < .001) relationships between VIET distance and maximal oxygen uptake (r = .74) and GXT maximal speed (r = .78) were observed. There were no significant differences between the VIET performance test and retest (1542.1 ± 338.1 vs 1567.1 ± 358.2 m). Significant (P < .001) relationships and intraclass correlation coefficient (ICC) were found (r = .95, ICC = .96) for VIET performance. VIET performance increased significantly (P < .001) with player performance level and was sensitive to fitness changes across the season (1458.8 ± 343.5 vs 1581.1 ± 334.0 m, P < .01). The VIET may be considered a valid, reliable, and sensitive test to assess the aerobic endurance in volleyball players.

  7. Predicting Performance in Higher Education Using Proximal Predictors.

    PubMed

    Niessen, A Susan M; Meijer, Rob R; Tendeiro, Jorge N

    2016-01-01

    We studied the validity of two methods for predicting academic performance and student-program fit that were proximal to important study criteria. Applicants to an undergraduate psychology program participated in a selection procedure containing a trial-studying test based on a work sample approach, and specific skills tests in English and math. Test scores were used to predict academic achievement and progress after the first year, achievement in specific course types, enrollment, and dropout after the first year. All tests showed positive significant correlations with the criteria. The trial-studying test was consistently the best predictor in the admission procedure. We found no significant differences between the predictive validity of the trial-studying test and prior educational performance, and substantial shared explained variance between the two predictors. Only applicants with lower trial-studying scores were significantly less likely to enroll in the program. In conclusion, the trial-studying test yielded predictive validities similar to that of prior educational performance and possibly enabled self-selection. In admissions aimed at student-program fit, or in admissions in which past educational performance is difficult to use, a trial-studying test is a good instrument to predict academic performance.

  8. Morning-evening difference of team-handball-related short-term maximal physical performances in female team handball players.

    PubMed

    Mhenni, Thouraya; Michalsik, Lars Bojsen; Mejri, Mohamed Arbi; Yousfi, Narimen; Chaouachi, Anis; Souissi, Nizar; Chamari, Karim

    2017-05-01

    This study investigated the two different time-of-day effect on team-handball-related short-term maximal physical performances. At two different time-of-day, fifteen young female team handball players performed different physical tests: HandGrip (HG) test, Ball-Throwing Velocity (BTV) test, Modified Agility T-test (MAT) and Repeated Shuttle-Sprint and Jump Ability (RSSJA) test. Rating of perceived exertion (RPE) scale was determined following the termination of the last test. Measurements were performed at two separate testing sessions (i.e., in the morning (7:00-8:30 h) and in the early evening (17:00-18:30 h)) in a randomised and counter-balanced setting on non-consecutive days. The results showed that HG (P = 0.0013), BTV (P = 0.0027) and MAT (P < 0.001) performances were better in the evening compared with the morning. During RSSJA, both best and mean sprint times were shorter in the evening compared to the morning (P < 0.001). Moreover, during the latter test, mean jump performance was higher in the evening compared to the morning (P = 0.026). However, there was no morning-evening difference in the best jump performance during RSSJA. Likewise, jump performance decrement was not affected by the time-of-day of testing. On the other hand, RPE fluctuated, with morning nadirs and afternoon/early evening highest values. The findings suggest that in female team handball players, team-handball-related short-term maximal physical performances were better in the afternoon than in the morning.

  9. Sex differences in effects of testing medium and response format on a visuospatial task.

    PubMed

    Cherney, Isabelle D; Rendell, Jariel A

    2010-06-01

    Sex differences on visuospatial tests are among the most reliably replicated. It is unclear to what extent these performance differences reflect underlying differences in skills or testing factors. To assess whether testing medium and response format affect visuospatial sex differences, performances of introductory psychology students (100 men, 104 women) were examined on a visuospatial task presented in paper-and-pencil and tablet computer forms. Both sexes performed better when tested on paper, although men outperformed women. The introduction of an open-ended component to the visuospatial task eliminated sex differences when prior spatial experiences were controlled, but men outperformed women when prior spatial experiences were not considered. In general, the open-ended version and computerized format of the test diminished performance, suggesting that response format and medium are testing factors that influence visuospatial abilities.

  10. Verification System: First System-Wide Performance Test

    NASA Astrophysics Data System (ADS)

    Chernobay, I.; Zerbo, L.

    2006-05-01

    System-wide performance tests are essential for the development, testing and evaluation of individual components of the verification system. In addition to evaluating global readiness it helps establishing the practical and financial requirements for eventual operations. The first system-wide performance test (SPT1) was conducted in three phases: - A preparatory phase in May-June 2004 - A performance testing phase in April-June 2005 - An evaluation phase in the last half of 2005. The preparatory phase was developmental in nature. The main objectives for the performance testing phase included establishment of performance baseline under current provisional mode of operation (CTBT/PC- 19/1/Annex II, CTBT/WGB-21/1), examination of established requirements and procedures for operation and maintenance. To establish a system-wide performance baseline the system configuration was fixed for April-May 2005. The third month (June 2005) was used for implementation of 21 test case scenarios to examine either particular operational procedures or the response of the system components to the failures simulated under controlled conditions. A total of 163 stations and 5 certified radionuclide laboratories of International Monitoring System (IMS) participated in the performance testing phase - about 50% of the eventual IMS network. 156 IMS facilities and 40 National Data Centres (NDCs) were connected to the International Data Centre (IDC) via Global Communication Infrastructure (GCI) communication links. In addition, 12 legacy stations in the auxiliary seismic network sent data to the IDC over the Internet. During the performance testing phase, the IDC produced all required products, analysed more than 6100 seismic events and 1700 radionuclide spectra. Performance of all system elements was documented and analysed. IDC products were compared with results of data processing at the NDCs. On the basis of statistics and information collected during the SPT1 a system-wide performance baseline under current guidelines for provisional Operation and Maintenance was established. The test provided feedback for further development of the draft IMS and IDC Operational Manuals and identified priority areas for further system development.

  11. Test and evaluation report for the Grumman-Olson Kurbwatt

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barnett, J.H.; Carter, C.L.; Metcalfe, J.K.

    1982-01-01

    This report documents the results obtained from tests performed on the Kurbwatt, an electric vehicle (EV) designed and constructed by Grumman Olson (a divison of Grumman Allied Industries, Inc.), between August 1981 and April 1982 at the Tennessee Valley Authority (TVA) Electric Vehicle Test Facility (EVTF) in Chattanooga, Tennessee. Data on vehicle physical characteristics and performance acquired during tests conducted under test track, dynamometer, and on-road conditions are presented along with descriptions of the vehicle and its components and information on the reliability of the vehicle during the test period. This testing was performed by TVA and was sponsored bymore » the Electric Power Research Institute (EPRI).« less

  12. Tracking techniques for space shuttle rendezvous

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The space shuttle rendezvous radar has a requirement to track cooperative and non-cooperative targets. For this reason the Lunar Module (LM) Rendezvous Radar was modified to incorporate the capability of tracking a non-cooperative target. The modifications are discussed. All modifications except those relating to frequency diversity were completed, and system tests were performed to confirm proper performance in the non-cooperative mode. Frequency diversity was added to the radar and to the special test equipment, and then system tests were performed. This last set of tests included re-running the tests of the non-cooperative mode without frequency diversity, followed by tests with frequency diversity and tests of operation in the original cooperative mode.

  13. Combined effects of hydrazine exposure and endurance testing on solenoid-actuated valve performance

    NASA Technical Reports Server (NTRS)

    Hagler, R., Jr.

    1974-01-01

    Results are presented from a test program which was conducted to assess the capability of various solenoid-actuated valve design concepts to provide performance characteristics commensurate with long-duration (ten-year) missions to explore the outer planets. The valves were installed in a hydrazine flow test setup and periodically cycled during a nine-month test period under test conditions comparable to anticipated mission operating conditions. In situ valve performance was periodically determined, and leakage was continuously monitored.

  14. James Webb Space Telescope (JWST) Integrated Sciene Instrument Module (ISIM) Cryo-Vac 3 (CV3) Thermal Vacuum Test

    NASA Technical Reports Server (NTRS)

    Packard, Ed

    2016-01-01

    This presentation describes the test objectives, test summary, test configuration and test performance of the James Webb Space Telescope Integrated Science Instrument Module CryoVac 3 Thermal Vacuum Test. Verify the ISIM System in its final configuration after environmental exposure and provide a post-environmental performance baseline, including critical ground calibrations needed for science data processing in flight.

  15. An Investigation of the Effects of Self-Adapted Testing on Examinee Effort and Performance in a Low-Stakes Achievement Test

    ERIC Educational Resources Information Center

    Wise, Steven L.; Owens, Kara M.; Yang, Sheng-Ta; Weiss, Brandi; Kissel, Hilary L.; Kong, Xiaojing; Horst, Sonia J.

    2005-01-01

    There are a variety of situations in which low-stakes achievement tests--which are defined as those having few or no consequences for examinee performance--are used in applied measurement. A problem inherent in such testing is that we often cannot assume that all examinees give their best effort to their test, which suggests that the test scores…

  16. Thermal Performance Testing of EMU and CSAFE Liquid Cooling Gannents

    NASA Technical Reports Server (NTRS)

    Rhodes, Richard; Bue, Grant; Meginnis, Ian; Hakam, Mary; Radford, Tamara

    2013-01-01

    Future exploration missions require the development of a new liquid cooling garment (LCG) to support the next generation extravehicular activity (EVA) suit system. The new LCG must offer greater system reliability, optimal thermal performance as required by mission directive, and meet other design requirements including improved tactile comfort. To advance the development of a future LCG, a thermal performance test was conducted to evaluate: (1) the comparable thermal performance of the EMU LCG and the CSAFE developed engineering evaluation unit (EEU) LCG, (2) the effect of the thermal comfort undergarment (TCU) on the EMU LCG tactile and thermal comfort, and (3) the performance of a torso or upper body only LCG shirt to evaluate a proposed auxiliary loop. To evaluate the thermal performance of each configuration, a metabolic test was conducted using the Demonstrator Spacesuit to create a relevant test environment. Three (3) male test subjects of similar height and weight walked on a treadmill at various speeds to produce three different metabolic loads - resting (300-600 BTU/hr), walking at a slow pace (1200 BTU/hr), and walking at a brisk pace (2200 BTU/hr). Each subject participated in five tests - two wearing the CSAFE full LCG, one wearing the EMU LCG without TCUs, one wearing the EMU LCG with TCUs, and one with the CSAFE shirt-only. During the test, performance data for the breathing air and cooling water systems and subject specific data was collected to define the thermal performance of the configurations. The test results show that the CSAFE EEU LCG and EMU LCG with TCU had comparable performance. The testing also showed that an auxiliary loop LCG, sized similarly to the shirt-only configuration, should provide adequate cooling for contingency scenarios. Finally, the testing showed that the TCU did not significantly hinder LCG heat transfer, and may prove to be acceptable for future suit use with additional analysis and testing.

  17. Specific physiological and biomechanical performance in elite, sub-elite and in non-elite male team handball players.

    PubMed

    Wagner, Herbert; Fuchs, Philip X; von Duvillard, Serge P

    2018-01-01

    Team handball is a dynamic sport game that is played professionally in numerous countries. However, knowledge about training and competition is based mostly on practical experience due to limited scientific studies. Consequently, the aims of our study were to compare specific physiological and biomechanical performance in elite, sub-elite and in non-elite male team handball players. Thirty-six elite, sub-elite and non-elite male team handball players performed a game based performance test, upper-body and lower-body strength tests, 30-m sprint test, counter movement jump test and an incremental treadmill running test. Significant differences (P<0.05) were found for the peak oxygen uptake, heart rate, offense and defense time, jump height and ball velocity during the jump throw in the game based performance test, maximal oxygen uptake in the incremental treadmill running test as well as in maximal leg strength and leg explosive strength in the isometric strength test. Elite male players have an enhanced specific agility, a better throwing performance, a higher team handball specific oxygen uptake and higher leg strength compared to sub-elite and non-elite players. Based on these results we recommend that training in team handball should focus on game based training methods to improve performance in specific agility, endurance and technique.

  18. Sensitivity to change of the field-based Wheelchair Mobility Performance Test in wheelchair basketball.

    PubMed

    de Witte, Annemarie M H; Sjaarda, Fleur; Helleman, Jochem; Berger, Monique A M; van der Woude, Lucas H V; Hoozemans, Marco J M

    2018-06-15

    The Wheelchair Mobility Performance (WMP) test is a reliable and valid measure to assess mobility performance in wheelchair basketball. The aim of this study was to examine the sensitivity to change of the WMP test by manipulating wheelchair configurations. Sixteen wheelchair basketball players performed the WMP test 3 times in their own wheelchair: (i) without adjustments ("control condition"); (ii) with 10 kg additional mass ("weighted condition"); and (iii) with 50% reduced tyre pressure ("tyre condition"). The outcome measure was time (s). If paired t-tests were significant (p <0.05) and differences between conditions were larger than the standard error of measurement, the effect sizes (ES) were used to evaluate the sensitivity to change. ES values ≥0.2 were regarded as sensitive to change. The overall performance times for the manipulations were significantly higher than the control condition, with mean differences of 4.40 s (weight - control, ES = 0.44) and 2.81 s (tyre - control, ES = 0.27). The overall performance time on the WMP test was judged as sensitive to change. For 8 of the 15 separate tasks on the WMP test, the tasks were judged as sensitive to change for at least one of the manipulations. The WMP test can detect change in mobility performance when wheelchair configurations are manipulated.

  19. Staged-Fault Testing of Distance Protection Relay Settings

    NASA Astrophysics Data System (ADS)

    Havelka, J.; Malarić, R.; Frlan, K.

    2012-01-01

    In order to analyze the operation of the protection system during induced fault testing in the Croatian power system, a simulation using the CAPE software has been performed. The CAPE software (Computer-Aided Protection Engineering) is expert software intended primarily for relay protection engineers, which calculates current and voltage values during faults in the power system, so that relay protection devices can be properly set up. Once the accuracy of the simulation model had been confirmed, a series of simulations were performed in order to obtain the optimal fault location to test the protection system. The simulation results were used to specify the test sequence definitions for the end-to-end relay testing using advanced testing equipment with GPS synchronization for secondary injection in protection schemes based on communication. The objective of the end-to-end testing was to perform field validation of the protection settings, including verification of the circuit breaker operation, telecommunication channel time and the effectiveness of the relay algorithms. Once the end-to-end secondary injection testing had been completed, the induced fault testing was performed with three-end lines loaded and in service. This paper describes and analyses the test procedure, consisting of CAPE simulations, end-to-end test with advanced secondary equipment and staged-fault test of a three-end power line in the Croatian transmission system.

  20. Aerobic fitness testing in 6- to 9-year-old children: reliability and validity of a modified Yo-Yo IR1 test and the Andersen test.

    PubMed

    Ahler, T; Bendiksen, M; Krustrup, P; Wedderkopp, N

    2012-03-01

    This study analysed the reliability and validity of two intermittent running tests (the Yo-Yo IR1 test and the Andersen test) as tools for estimating VO(2max) in children under the age of 10. Two groups, aged 6-7 years (grade 0, n = 18) and 8-9 years (grade 2, n = 16), carried out two repetitions of a modified Yo-Yo IR1 test (2 × 16 m) and the Andersen test, as well as an incremental treadmill test, to directly determine the VO(2max). No significant differences were observed in test-retest performance of the Yo-Yo IR1 test [693 ± 418 (±SD) and 670 ± 328 m, r (2) = 0.79, CV = 19%, p > 0.05, n = 32) and the Andersen test (988 ± 77 and 989 ± 87 m, r (2) = 0.86, CV = 3%, p > 0.05, n = 31). The Yo-Yo IR1 (r (2) = 0.47, n = 31, p < 0.002) and Andersen test performance (r (2) = 0.53, n = 32, p < 0.001) correlated with the VO(2max). Yo-Yo IR1 performance correlated with Andersen test performance (r (2) = 0.74, n = 32, p < 0.0001). In conclusion, the Yo-Yo IR1 and the Andersen tests are reproducible and can be used as an indicator of aerobic fitness for 6- to 9-year-old children.

Top