Thornberg, Steven [Peralta, NM; Brown, Jason [Albuquerque, NM
2012-06-19
A method of detecting leaks and measuring volumes as well as an apparatus, the Power-free Pump Module (PPM), that is a self-contained leak test and volume measurement apparatus that requires no external sources of electrical power during leak testing or volume measurement, where the invention is a portable, pneumatically-controlled instrument capable of generating a vacuum, calibrating volumes, and performing quantitative leak tests on a closed test system or device, all without the use of alternating current (AC) power. Capabilities include the ability is to provide a modest vacuum (less than 10 Torr), perform a pressure rise leak test, measure the gas's absolute pressure, and perform volume measurements. All operations are performed through a simple rotary control valve which controls pneumatically-operated manifold valves.
Thornberg, Steven M; Brown, Jason
2015-02-17
A method of detecting leaks and measuring volumes as well as a device, the Power-free Pump Module (PPM), provides a self-contained leak test and volume measurement apparatus that requires no external sources of electrical power during leak testing or volume measurement. The PPM is a portable, pneumatically-controlled instrument capable of generating a vacuum, calibrating volumes, and performing quantitative leak tests on a closed test system or device, all without the use of alternating current (AC) power. Capabilities include the ability is to provide a modest vacuum (less than 10 Torr) using a venturi pump, perform a pressure rise leak test, measure the gas's absolute pressure, and perform volume measurements. All operations are performed through a simple rotary control valve which controls pneumatically-operated manifold valves.
1992-01-01
SUBTmI.E 5 FU.NDING NUMBERS Job Performance Tests for CII-53E Helicopter Miechanacs - Volume I1: Admiutstrative Duties and Job Knowlede Tests C - N...performance measures to Marine Corps personnel managers . training instructors, and interested researchers who may find them useful. This work comprises...Corps personnel managers , training instructors, and interested researchers who may find them useful. 3. This work comprises two parts: volume I
Relationship of Temporal Lobe Volumes to Neuropsychological Test Performance in Healthy Children
Wells, Carolyn T.; Matson, Melissa A.; Kates, Wendy R.; Hay, Trisha; Horska, Alena
2008-01-01
Ecological validity of neuropsychological assessment includes the ability of tests to predict real-world functioning and/or covary with brain structures. Studies have examined the relationship between adaptive skills and test performance, with less focus on the association between regional brain volumes and neurobehavioral function in healthy children. The present study examined the relationship between temporal lobe gray matter volumes and performance on two neuropsychological tests hypothesized to measure temporal lobe functioning (Visual Perception-VP; Peabody Picture Vocabulary Test, Third Edition-PPVT-III) in 48 healthy children ages 5-18 years. After controlling for age and gender, left and right temporal and left occipital volumes were significant predictors of VP. Left and right frontal and temporal volumes were significant predictors of PPVT-III. Temporal volume emerged as the strongest lobar correlate with both tests. These results provide convergent and discriminant validity supporting VP as a measure of the “what” system; but suggest the PPVT-III as a complex measure of receptive vocabulary, potentially involving executive function demands. PMID:18513844
Clemente-Suárez, Vicente Javier; Delgado-Moreno, Rosa; González, Beatriz; Ortega, Javier; Ramos-Campo, Domingo Jesús
2018-04-12
The aim of the present research was to compare the effects in swimming and running performance, horizontal jump test, autonomic modulation, and body composition of four training weeks with emphasis on volume versus intensity in moderate trained triathletes. Thirty-two amateur triathletes (20 males and 12 females) were randomly divided in three different groups that performed 6 training session per week: Intensity (INT): training focused on performs intensity training Volume (VOL): training focused on performs volume training; and Control (CON): physical active group with no periodized training. Body composition, heart rate variability, horizontal jump test, swimming and 2000 m running test were tested before and after the training period. There were no significant differences between INT and VOL in running test. Furthermore, both INT and VOL training groups improved 50 m (p: 0.046 and 0.042 respectively) and 400 m (p: 0.044 and 0.041 respectively) swimming performance. Moreover, there were no significant differences among groups in any moment in HRV variables. No significant difference was observed for horizontal jump test and body composition between the INT and VOL group at any time. According to the results of the present study, four weeks of training with either high intensity or volume results to similar adaptations in endurance, horizontal jump test and body composition parameters in amateur triathletes. Copyright © 2018. Published by Elsevier Inc.
Relationship of Temporal Lobe Volumes to Neuropsychological Test Performance in Healthy Children
ERIC Educational Resources Information Center
Wells, Carolyn T.; Mahone, E. Mark; Matson, Melissa A.; Kates, Wendy R.; Hay, Trisha; Horska, Alena
2008-01-01
Ecological validity of neuropsychological assessment includes the ability of tests to predict real-world functioning and/or covary with brain structures. Studies have examined the relationship between adaptive skills and test performance, with less focus on the association between regional brain volumes and neurobehavioral function in healthy…
Contemporary bloodletting in cardiac surgical care.
Koch, Colleen G; Reineks, Edmunds Z; Tang, Anne S; Hixson, Eric D; Phillips, Shannon; Sabik, Joseph F; Henderson, J Michael; Blackstone, Eugene H
2015-03-01
Health care providers are seldom aware of the frequency and volume of phlebotomy for laboratory testing, bloodletting that often leads to hospital-acquired anemia. Our objectives were to examine the frequency of laboratory testing in patients undergoing cardiac surgery, calculate cumulative phlebotomy volume from time of initial surgical consultation to hospital discharge, and propose strategies to reduce phlebotomy volume. From January 1, 2012 to June 30, 2012, 1,894 patients underwent cardiac surgery at Cleveland Clinic; 1,867 had 1 hospitalization and 27 had 2. Each laboratory test was associated with a test name and blood volume. Phlebotomy volume was estimated separately for the intensive care unit (ICU), hospital floors, and cumulatively. A total of 221,498 laboratory tests were performed, averaging 115 tests per patient. The most frequently performed tests were 88,068 blood gas analyses, 39,535 coagulation tests, 30,421 complete blood counts, and 29,374 metabolic panels. Phlebotomy volume differed between ICU and hospital floors, with median volumes of 332 mL and 118 mL, respectively. Cumulative median volume for the entire hospital stay was 454 mL. More complex procedures were associated with higher overall phlebotomy volume than isolated procedures; eg, combined coronary artery bypass grafting (CABG) and valve procedure median volume was 653 mL (25th/75th percentiles, 428 of 1,065 mL) versus 448 mL (284 of 658 mL) for isolated CABG and 338 mL (237 of 619) for isolated valve procedures. We were astonished by the extent of bloodletting, with total phlebotomy volumes approaching amounts equivalent to 1 to 2 red blood cell units. Implementation of process improvement initiatives can potentially reduce phlebotomy volumes and resource utilization. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Aslaksen, Per M; Bystad, Martin K; Ørbo, Marte C; Vangberg, Torgil R
2018-06-08
Total hippocampal volume has previously been shown to correlate with performance on tests for verbal episodic memory. However, there are sparse evidence on how hippocampal subfield volumes are related to verbal episodic memory in healthy adults. The present study investigated the association between volumes of separate hippocampal subfields and verbal episodic memory performance in healthy volunteers. Forty-seven participants (31 females) between 20 to 71 years age underwent testing with the California Verbal Learning Test II (CVLT II), and the Wechsler Abbreviated Scale of Intelligence (WASI) to obtain an estimate of cognitive functioning. T1-weighted MR images were obtained after cognitive testing, and volumetric estimates adjusted for age and estimated total intracranial volume were calculated in the FreeSurfer 6.0 software suite for cerebral -and hippocampal structures. The sample performed within the statistical normal range on both CVLT II and WASI. Significant correlations adjusted for multiple testing were found between CVLT II subtests of total learning, free immediate recall and free delayed recall and volumes of the left Cornu Ammonis (CA) 1-4 subfields. There were no significant correlations between right hippocampal subfields and CVLT II performance, and no significant correlation between WASI results and hippocampal subfields. The present results suggest that better verbal episodic memory measured by the CVLT II is associated with relative larger volumes of specific left CA hippocampal subfields in healthy adults. Due to the small sample size and large age-span of the participants, the present findings are preliminary and should be confirmed in larger samples. Copyright © 2018 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCright, R D
1998-06-30
This Engineered Materials Characterization Report (EMCR), Volume 3, discusses in considerable detail the work of the past 18 months on testing the candidate materials proposed for the waste-package (WP) container and on modeling the performance of those materials in the Yucca Mountain (YM) repository setting This report was prepared as an update of information and serves as one of the supporting documents to the Viability Assessment (VA) of the Yucca Mountain Project. Previous versions of the EMCR have provided a history and background of container-materials selection and evaluation (Volume I), a compilation of physical and mechanical properties for the WPmore » design effort (Volume 2), and corrosion-test data and performance-modeling activities (Volume 3). Because the information in Volumes 1 and 2 is still largely current, those volumes are not being revised. As new information becomes available in the testing and modeling efforts, Volume 3 is periodically updated to include that information.« less
DOT National Transportation Integrated Search
1975-01-01
The six-volume report presents the technical methodology, data samples, and results of tests conducted on the SOAC on the Rail Transit Test Track at the High Speed Ground Test Center in Pueblo, Colorado during the period April to July 1973. The Test ...
Hippocampal volume and memory performance in children with perinatal stroke.
Gold, Jeffrey J; Trauner, Doris A
2014-01-01
Pediatric neurologists and neonatologists often are asked to predict cognitive outcome after perinatal brain injury (including likely memory and learning outcomes). However, relatively few data exist on how accurate predictions can be made. Furthermore, although the consequences of brain injury on hippocampal volume and memory performance have been studied extensively in adults, little work has been done in children. We measured the volume of the hippocampus in 27 children with perinatal stroke and 19 controls, and measured their performance on standardized verbal and non-verbal memory tests. We discovered the following: (1) As a group, children with perinatal stroke had smaller left and right hippocampi compared with control children. (2) Individually, children with perinatal stroke demonstrated 1 of 3 findings: no hippocampal loss, unilateral hippocampal loss, or bilateral hippocampal volume loss compared with control children. (3) Hippocampal volume inversely correlated with memory test performance in the perinatal stroke group, with smaller left and right hippocampal volumes related to poorer verbal and non-verbal memory test performance, respectively. (4) Seizures played a significant role in determining memory deficit and extent of hippocampal volume reduction in patients with perinatal stroke. These findings support the view that, in the developing brain, the left and right hippocampi preferentially support verbal and nonverbal memory respectively, a consistent finding in the adult literature but a subject of debate in the pediatric literature. This is the first work to report that children with focal brain injury incurred from perinatal stroke have volume reduction in the hippocampus and impairments in certain aspects of declarative memory. Copyright © 2014 Elsevier Inc. All rights reserved.
Bokov, P; Delclaux, C
2016-02-01
Resting pulmonary function tests (PFT) include the assessment of ventilatory capacity: spirometry (forced expiratory flows and mobilisable volumes) and static volume assessment, notably using body plethysmography. Spirometry allows the potential definition of obstructive defect, while static volume assessment allows the potential definition of restrictive defect (decrease in total lung capacity) and thoracic hyperinflation (increase in static volumes). It must be kept in mind that this evaluation is incomplete and that an assessment of ventilatory demand is often warranted, especially when facing dyspnoea: evaluation of arterial blood gas (searching for respiratory insufficiency) and measurement of the transfer coefficient of the lung, allowing with the measurement of alveolar volume to calculate the diffusing capacity of the lung for CO (DLCO: assessment of alveolar-capillary wall and capillary blood volume). All these pulmonary function tests have been the subject of an Americano-European Task force (standardisation of lung function testing) published in 2005, and translated in French in 2007. Interpretative strategies for lung function tests have been recommended, which define abnormal lung function tests using the 5th and 95th percentiles of predicted values (lower and upper limits of normal values). Thus, these recommendations need to be implemented in all pulmonary function test units. A methacholine challenge test will only be performed in the presence of an intermediate pre-test probability for asthma (diagnostic uncertainty), which is an infrequent setting. The most convenient exertional test is the 6-minute walk test that allows the assessment of walking performance, the search for arterial desaturation and the quantification of dyspnoea complaint. Copyright © 2015 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.
De Cola, Maria Cristina; D'Aleo, Giangaetano; Sessa, Edoardo; Marino, Silvia
2015-01-01
Objective. To investigate the influence of demographic and clinical variables, such as depression, fatigue, and quantitative MRI marker on cognitive performances in a sample of patients affected by multiple sclerosis (MS). Methods. 60 MS patients (52 relapsing remitting and 8 primary progressive) underwent neuropsychological assessments using Rao's Brief Repeatable Battery of Neuropsychological Tests (BRB-N), the Beck Depression Inventory-second edition (BDI-II), and the Fatigue Severity Scale (FSS). We performed magnetic resonance imaging to all subjects using a 3 T scanner and obtained tissue-specific volumes (normalized brain volume and cortical brain volume). We used Student's t-test to compare depressed and nondepressed MS patients. Finally, we performed a multivariate regression analysis in order to assess possible predictors of patients' cognitive outcome among demographic and clinical variables. Results. 27.12% of the sample (16/59) was cognitively impaired, especially in tasks requiring attention and information processing speed. From between group comparison, we find that depressed patients had worse performances on BRB-N score, greater disability and disease duration, and brain volume decrease. According to multiple regression analysis, the BDI-II score was a significant predictor for most of the neuropsychological tests. Conclusions. Our findings suggest that the presence of depressive symptoms is an important determinant of cognitive performance in MS patients. PMID:25861633
NASA Technical Reports Server (NTRS)
1975-01-01
Three-volume publication covers theoretical, design, and performance aspects of turbines. Volumes cover thermodynamic and fluid-dynamic concepts, velocity diagram design, turbine blade aerodynamic design, turbine energy losses, supersonic turbines, radial-inflow turbines, turbine cooling, and aerodynamic performance testing.
Volume vs. intensity in the training of competitive swimmers.
Faude, O; Meyer, T; Scharhag, J; Weins, F; Urhausen, A; Kindermann, W
2008-11-01
The present study aimed at comparing a high-volume, low-intensity vs. low-volume, high-intensity swim training. In a randomized cross-over design, 10 competitive swimmers performed two different 4-week training periods, each followed by an identical taper week. One training period was characterized by a high-training volume (HVT) whereas high-intensity training was prevalent during the other program (HIT). Before, after two and four weeks and after the taper week subjects performed psychometric and performance testing: profile of mood states (POMS), incremental swimming test (determination of individual anaerobic threshold, IAT), 100 m and 400 m. A small significant increase in IAT was observed after taper periods compared to pre-training (+ 0.01 m/s; p = 0.01). Maximal 100-m and 400-m times were not significantly affected by training. The POMS subscore of "vigor" decreased slightly after both training periods (p = 0.06). None of the investigated parameters showed a significant interaction between test-time and training type (p > 0.13). Nearly all (83 %) subjects swam personal best times during the 3 months after each training cycle. It is concluded that, for a period of 4 weeks, high-training volumes have no advantage compared to high-intensity training of lower volume.
ERIC Educational Resources Information Center
Frederickson, Edward W.; And Others
The development and evaluation of prototype hands-on equipment, job sample performance tests for a high skilled technical Military Occupational Specialty (MOS) are described. An electronic maintenance MOS (26C20) was used as the research vehicle. The results led to the conclusion that valid and reliable performance tests could be constructed, but…
The U.S. Environmental Protection Agency has standardized methods for performing acute marine amphipod sediment toxicity tests. A test design reducing sediment volume from 200 to 50 ml and overlying water from 600 to 150 ml was recently proposed. An interlaboratory comparison wa...
Relationships between maximal anaerobic power of the arms and legs and javelin performance.
Bouhlel, E; Chelly, M S; Tabka, Z; Shephard, R
2007-06-01
The aim of this study was to examine relationships between maximal anaerobic power, as measured by leg and arm force-velocity tests, estimates of local muscle volume and javelin performance. Ten trained national level male javelin throwers (mean age 19.6+/- 2 years) participated in this study. Maximal anaerobic power, maximal force and maximal velocity were measured during leg (Wmax-L) and arm (Wmax-A) force-velocity tests, performed on appropriately modified forms of Monark cycle ergometer. Estimates of leg and arm muscle volume were made using a standard anthropometric kit. Maximal force of the leg (Fmax-L) was significantly correlated with estimated leg muscle volume (r=0.71, P<0.05). Wmax-L and Wmax-A were both significantly correlated with javelin performance (r=0.76, P<0.01; r=0.71, P <0.05, respectively). Maximal velocity of the leg (Vmax-L) was also significantly correlated with throwing performance (r=0.83; P<0.001). Wmax of both legs and arms were significantly correlated with javelin performance, the closest correlation being for Wmax-L; this emphasizes the importance of the leg muscles in this sport. Fmax-L and Vmax-L were related to muscle volume and to javelin performance, respectively. Force-velocity testing may have value in regulating conditioning and rehabilitation in sports involving throwing.
ERIC Educational Resources Information Center
Rice, Linda Maxwell; And Others
These performance tests for the area of cosmetology consist of a sampling technique (domain referenced tests) which covers all the possible performance situations. When used in total, they may also serve as a comprehensive test. Introductory materials discuss domain referenced testing, determining the domains, and developing performance testing…
Effects of plyometric training volume and training surface on explosive strength.
Ramírez-Campillo, Rodrigo; Andrade, David C; Izquierdo, Mikel
2013-10-01
The purpose of this study is to examine the effects of different volume and training surfaces during a short-term plyometric training program on neuromuscular performance. Twenty-nine subjects were randomly assigned to 4 groups: control group (CG, n = 5), moderate volume group (MVG, n = 9, 780 jumps), moderate volume hard surface group (MVGHS, n = 8, 780 jumps), and high volume group (HVG, n = 7, 1,560 jumps). A series of tests were performed by the subjects before and after 7 weeks of plyometric training. These tests were measurement of maximum strength (5 maximum repetitions [5RMs]), drop jumps (DJs) of varying heights (20, 40, and 60 cm), squat and countermovement jumps (SJ and CMJ, respectively), timed 20-m sprint, agility, body weight, and height. The results of the present study suggest that high training volume leads to a significant increase in explosive performance that requires fast stretch-shortening cycle (SSC) actions (such as DJ and sprint) in comparison to what is observed after a moderate training volume regimen. Second, when plyometric training is performed on a hard training surface (high-impact reaction force), a moderate training volume induces optimal stimulus to increase explosive performance requiring fast SSC actions (e.g., DJ), maximal dynamic strength enhancement, and higher training efficiency. Thus, a finding of interest in the study was that after 7 weeks of plyometric training, performance enhancement in maximal strength and in actions requiring fast SSC (such as DJ and sprint) were dependent on the volume of training and the surface on which it was performed. This must be taken into account when using plyometric training on different surfaces.
Automobile driver on-road performance test. Volume 3, Examiner's manual
DOT National Transportation Integrated Search
1981-09-30
This report provides procedures for administering and scoring the Automobile Driver On-Road Performance Test (ADOPT). The ADOPT checks 21 separate driving performances. Performances are checked at pre-determined locations along a 10-minute route and ...
Automobile driver on-road performance test. Volume 2, Administrator's manual
DOT National Transportation Integrated Search
1981-09-30
This report provides procedures for setting up, administering, and scoring the Automobile Driver On-Road Performance Test (ADOPT). The ADOPT checks 21 separate driving performances. Performances are checked at pre-determined locations along a 10-minu...
Clinical laboratory: bigger is not always better.
Plebani, Mario
2018-06-27
Laboratory services around the world are undergoing substantial consolidation and changes through mechanisms ranging from mergers, acquisitions and outsourcing, primarily based on expectations to improve efficiency, increasing volumes and reducing the cost per test. However, the relationship between volume and costs is not linear and numerous variables influence the end cost per test. In particular, the relationship between volumes and costs does not span the entire platter of clinical laboratories: high costs are associated with low volumes up to a threshold of 1 million test per year. Over this threshold, there is no linear association between volumes and costs, as laboratory organization rather than test volume more significantly affects the final costs. Currently, data on laboratory errors and associated diagnostic errors and risk for patient harm emphasize the need for a paradigmatic shift: from a focus on volumes and efficiency to a patient-centered vision restoring the nature of laboratory services as an integral part of the diagnostic and therapy process. Process and outcome quality indicators are effective tools to measure and improve laboratory services, by stimulating a competition based on intra- and extra-analytical performance specifications, intermediate outcomes and customer satisfaction. Rather than competing with economic value, clinical laboratories should adopt a strategy based on a set of harmonized quality indicators and performance specifications, active laboratory stewardship, and improved patient safety.
NASA Astrophysics Data System (ADS)
Ferrucci, M.; Muralikrishnan, B.; Sawyer, D.; Phillips, S.; Petrov, P.; Yakovlev, Y.; Astrelin, A.; Milligan, S.; Palmateer, J.
2014-10-01
Large volume laser scanners are increasingly being used for a variety of dimensional metrology applications. Methods to evaluate the performance of these scanners are still under development and there are currently no documentary standards available. This paper describes the results of extensive ranging and volumetric performance tests conducted on a large volume laser scanner. The results demonstrated small but clear systematic errors that are explained in the context of a geometric error model for the instrument. The instrument was subsequently returned to the manufacturer for factory calibration. The ranging and volumetric tests were performed again and the results are compared against those obtained prior to the factory calibration.
Brain tissue volumes in relation to cognitive function and risk of dementia.
Ikram, M Arfan; Vrooman, Henri A; Vernooij, Meike W; den Heijer, Tom; Hofman, Albert; Niessen, Wiro J; van der Lugt, Aad; Koudstaal, Peter J; Breteler, Monique M B
2010-03-01
We investigated in a population-based cohort study the association of global and lobar brain tissue volumes with specific cognitive domains and risk of dementia. Participants (n=490; 60-90 years) were non-demented at baseline (1995-1996). From baseline brain MRI-scans we obtained global and lobar volumes of CSF, GM, normal WM, white matter lesions and hippocampus. We performed neuropsychological testing at baseline to assess information processing speed, executive function, memory function and global cognitive function. Participants were followed for incident dementia until January 1, 2005. Larger volumes of CSF and WML were associated with worse performance on all neuropsychological tests, and an increased risk of dementia. Smaller WM volume was related to poorer information processing speed and executive function. In contrast, smaller GM volume was associated with worse memory function and increased risk of dementia. When investigating lobar GM volumes, we found that hippocampal volume and temporal GM volume were most strongly associated with risk of dementia, even in persons without objective and subjective cognitive deficits at baseline, followed by frontal and parietal GM volumes. Copyright 2008 Elsevier Inc. All rights reserved.
Howanitz, Peter J; Jones, Bruce A
2004-07-01
One of the major attributes of laboratory testing is cost. Although fully automated central laboratory glucose testing and semiautomated bedside glucose testing (BGT) are performed at most institutions, rigorous determinations of interinstitutional comparative costs have not been performed. To compare interinstitutional analytical costs of central laboratory glucose testing and BGT and to provide suggestions for improvement. Participants completed a demographic form about their institutional glucose monitoring practices. They also collected information about the costs of central laboratory glucose testing, BGT at a high-volume testing site, and BGT at a low-volume testing site, including specified cost variables for labor, reagents, and instruments. A total of 445 institutions enrolled in the College of American Pathologists Q-Probes program. Median cost per glucose test at 3 testing sites. The median (10th-90th percentile range) costs per glucose test were 1.18 dollars (5.59 dollars-0.36 dollars), 1.96 dollars (9.51 dollars-0.77 dollars), and 4.66 dollars (27.54 dollars-1.02 dollars) for central laboratory, high-volume BGT sites, and low-volume BGT sites, respectively. The largest percentages of the cost per test were for labor (59.3%, 72.7%, and 85.8%), followed by supplies (27.2%, 27.3%, and 13.4%) and equipment (2.1%, 0.0%, and 0.0%) for the 3 sites, respectively. The median number of patient specimens per month at the high-volume BGT sites was 625 compared to 30 at the low-volume BGT sites. Most participants did not include labor, instrument maintenance, competency assessment, or oversight in their BGT estimated costs until required to do so for the study. Analytical costs per glucose test were lower for central laboratory glucose testing than for BGT, which, in turn, was highly variable and dependent on volume. Data that would be used for financial justification for BGT were widely aberrant and in need of improvement.
A study of emissions from passenger cars in six cities. Volume B. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1979-01-01
This is the second of two volumes presenting results from a series of exhaust emission and fuel economy tests performed on a representative sample of vehicles in six U.S. cities. Data presented in the following sections are generated in appendix form as part of a contract with the EPA to perform work for the FY 77 Passenger Car Emission Factor Program. Volume B includes the balance of individual vehicle data derived from the Two Speed Idle and Federal Three Mode tests. It also includes the results of Vehicle Driveability Evaluations, Maladjustment and Disablement Inspections, tire inspections and a listing ofmore » comparative mileage data. Information presented in Volume B should not be interpreted without the benefit of additional descriptive data presented in Volume A as both volumes comprise the results of a single work effort and are not intended to be considered separately.« less
NASA Technical Reports Server (NTRS)
Hawkins-Reynolds, Ebony; Le, Hung; Stephan, Ryan
2010-01-01
Microchannel technology can be incorporated into heat exchanger designs to decrease the mass and volume of space hardware. The National Aeronautics and Space Administration at the Johnson Space Center (NASA JSC) partnered with Pacific Northwest National Laboratories (PNNL) to develop a liquid/liquid microchannel heat exchanger that has significant mass and volume savings without sacrificing thermal and pressure drop performance. PNNL designed the microchannel heat exchanger to the same performance design requirements of a conventional plate and fin liquid/liquid heat exchanger; 3 kW duty with inlet temperatures of 26 C and 4 C. Both heat exchangers were tested using the same test parameters on a test apparatus and performance data compared.
NASA Technical Reports Server (NTRS)
1978-01-01
The design and testing of the over the wing engine, a high bypass, geared turbofan engine, are discussed. The propulsion system performance is examined for uninstalled performance and installed performance. The fan aerodynamic performance and the D nozzle and reverser thrust performance are evaluated.
Macdermid, Paul William; Fink, Philip W; Stannard, Stephen R
2015-01-01
This investigation sets out to assess the effect of five different models of mountain bike tyre on rolling performance over hard-pack mud. Independent characteristics included total weight, volume, tread surface area and tread depth. One male cyclist performed multiple (30) trials of a deceleration field test to assess reliability. Further tests performed on a separate occasion included multiple (15) trials of the deceleration test and six fixed power output hill climb tests for each tyre. The deceleration test proved to be reliable as a means of assessing rolling performance via differences in initial and final speed (coefficient of variation (CV) = 4.52%). Overall differences between tyre performance for both deceleration test (P = 0.014) and hill climb (P = 0.032) were found, enabling significant (P < 0.0001 and P = 0.049) models to be generated, allowing tyre performance prediction based on tyre characteristics. The ideal tyre for rolling and climbing performance on hard-pack surfaces would be to decrease tyre weight by way of reductions in tread surface area and tread depth while keeping volume high.
The Effect of Instruction on the Acquisition of Conservation of Volume.
ERIC Educational Resources Information Center
Butts, David P.; Howe, Ann C.
Tested was the hypothesis that science instruction based on task analysis will lead to the acquisition of the ability to perform certain Piaget volume tasks which have been characterized as requiring formal operations for their solutions. A Test on Formal Operations and a Learning Hierarchies Test were given to fourth- and sixth-grade students in…
Performance indicators and decision making for outsourcing public health laboratory services.
Santos, Maria Angelica Borges dos; Moraes, Ricardo Montes de; Passos, Sonia Regina Lambert
2012-06-01
To develop performance indicators for outsourcing clinical laboratory services, based on information systems and public administrative records. In the municipality of Rio de Janeiro, Southern Brazil, the public health laboratory network comprised 33 laboratories with automated equipment (but no integrated information system), 90 primary care units (where sample collection was performed) and 983 employees. Information records were obtained from the administrative records of the Budget Information System for Public Health and the Outpatient and Hospital Information System of the Unified Health System. Performance indicators (production, productivity, usage and costs) were generated from data collected routinely from 2006 to 2008. The variations in production, costs and unit prices for tests were analyzed by Laspeyres and Paasche indices, which specifically measure laboratory activity, and by the Consumer Price Index from the Brazilian Institute of Geography and Statistics. A total of 10,359,111 tests were performed in 2008 (10.6% increase over 2006), and the test/employee ratio grew by 8.6%. The costs of supplies, wages and providers increased by 2.3%, 45.4% and 18.3%, respectively. The laboratory tests per visit and hospitalizations increased by 10% and 20%, respectively. The direct costs totaled R$ 63.2 million in 2008, representing an increase of 22.2% in current values during the period analyzed. The direct costs deflated by the Brazilian National Consumer Price Index (9.5% for the period) showed an 11.6% increase in production volumes. The activity-specific volume index, which considers changes in the mix of tests, showed increases of 18.5% in the test price and 3.1% in the production volume. The performance indicators, particularly the specific indices for volume and price of activity, constitute a baseline of performance potential for monitoring private laboratories and contractors. The economic performance indicators demonstrated the need for network information system integration prior to an outsourcing decision.
Tomaiuolo, F; Carlesimo, G; Di, P; Petrides, M; Fera, F; Bonanni, R; Formisano, R; Pasqualetti, P; Caltagirone, C
2004-01-01
Objective: The gross morphology and morphometry of the hippocampus, fornix, and corpus callosum in patients with severe non-missile traumatic brain injury (nmTBI) without obvious neuroradiological lesions was examined and the volumes of these structures were correlated with performance on memory tests. In addition, the predictability of the length of coma from the selected anatomical volumes was examined. Method: High spatial resolution T1 weighted MRI scans of the brain (1 mm3) and neuropsychological evaluations with standardised tests were performed at least 3 months after trauma in 19 patients. Results: In comparison with control subjects matched in terms of gender and age, volume reduction in the hippocampus, fornix, and corpus callosum of the nmTBI patients was quantitatively significant. The length of coma correlated with the volume reduction in the corpus callosum. Immediate free recall of word lists correlated with the volume of the fornix and the corpus callosum. Delayed recall of word lists and immediate recall of the Rey figure both correlated with the volume of the fornix. Delayed recall of the Rey figure correlated with the volume of the fornix and the right hippocampus. Conclusion: These findings demonstrate that in severe nmTBI without obvious neuroradiological lesions there is a clear hippocampal, fornix, and callosal volume reduction. The length of coma predicts the callosal volume reduction, which could be considered a marker of the severity of axonal loss. A few memory test scores correlated with the volumes of the selected anatomical structures. This relationship with memory performance may reflect the diffuse nature of the damage, leading to the disruption of neural circuits at multiple levels and the progressive neural degeneration occurring in TBI. PMID:15314123
NCAT test track design, construction, and performance
DOT National Transportation Integrated Search
2002-11-01
Empirical laboratory tests have been used for years to test hot mix asphalt (HMA) to determine the potential for various mixtures to perform well. As the amount of traffic has increased (higher volumes, higher loads, and increased tire pressures) the...
Sampaio-Baptista, Cassandra; Scholz, Jan; Jenkinson, Mark; Thomas, Adam G.; Filippini, Nicola; Smit, Gabrielle; Douaud, Gwenaëlle; Johansen-Berg, Heidi
2014-01-01
The ability to predict learning performance from brain imaging data has implications for selecting individuals for training or rehabilitation interventions. Here, we used structural MRI to test whether baseline variations in gray matter (GM) volume correlated with subsequent performance after a long-term training of a complex whole-body task. 44 naïve participants were scanned before undertaking daily juggling practice for 6 weeks, following either a high intensity or a low intensity training regime. To assess performance across the training period participants' practice sessions were filmed. Greater GM volume in medial occipito-parietal areas at baseline correlated with steeper learning slopes. We also tested whether practice time or performance outcomes modulated the degree of structural brain change detected between the baseline scan and additional scans performed immediately after training and following a further 4 weeks without training. Participants with better performance had higher increases in GM volume during the period following training (i.e., between scans 2 and 3) in dorsal parietal cortex and M1. When contrasting brain changes between the practice intensity groups, we did not find any straightforward effects of practice time though practice modulated the relationship between performance and GM volume change in dorsolateral prefrontal cortex. These results suggest that practice time and performance modulate the degree of structural brain change evoked by long-term training regimes. PMID:24680712
Code of Federal Regulations, 2012 CFR
2012-07-01
... per million dry volume 3-run average (1 hour minimum sample time per run) Performance test (Method 10... (Reapproved 2008) c. Oxides of nitrogen 53 parts per million dry volume 3-run average (1 hour minimum sample... average (1 hour minimum sample time per run) Performance test (Method 6 or 6c at 40 CFR part 60, appendix...
Code of Federal Regulations, 2011 CFR
2011-07-01
... per million dry volume 3-run average (1 hour minimum sample time per run) Performance test (Method 10... (Reapproved 2008) c. Oxides of nitrogen 53 parts per million dry volume 3-run average (1 hour minimum sample... average (1 hour minimum sample time per run) Performance test (Method 6 or 6c at 40 CFR part 60, appendix...
Code of Federal Regulations, 2014 CFR
2014-07-01
... parts per million by dry volume 3-run average (1 hour minimum sample time per run) Performance test..., appendix A-4). Oxides of nitrogen 388 parts per million by dry volume 3-run average (1 hour minimum sample... (1 hour minimum sample time per run) Performance test (Method 6 or 6c of appendix A of this part) a...
Code of Federal Regulations, 2013 CFR
2013-07-01
... parts per million by dry volume 3-run average (1 hour minimum sample time per run) Performance test..., appendix A-4). Oxides of nitrogen 388 parts per million by dry volume 3-run average (1 hour minimum sample... (1 hour minimum sample time per run) Performance test (Method 6 or 6c of appendix A of this part) a...
Verbal and non-verbal memory and hippocampal volumes in a memory clinic population.
Bonner-Jackson, Aaron; Mahmoud, Shamseldeen; Miller, Justin; Banks, Sarah J
2015-10-15
Better characterization of the relationship between episodic memory and hippocampal volumes is crucial in early detection of neurodegenerative disease. We examined these relationships in a memory clinic population. Participants (n = 226) underwent structural magnetic resonance imaging and tests of verbal (Hopkins Verbal Learning Test-Revised, HVLT-R) and non-verbal (Brief Visuospatial Memory Test-Revised, BVMT-R) memory. Correlational analyses were performed, and analyses on clinical subgroups (i.e., amnestic Mild Cognitive Impairment, non-amnestic Mild Cognitive Impairment, probable Alzheimer's disease, intact memory) were conducted. Positive associations were identified between bilateral hippocampal volumes and both memory measures, and BVMT-R learning slope was more strongly positively associated with hippocampal volumes than HVLT-R learning slope. Amnestic Mild Cognitive Impairment (aMCI) participants showed specific positive associations between BVMT-R performance and hippocampal volumes bilaterally. Additionally, analyses of the aMCI group showed trend-level evidence of material-specific lateralization, such that retention of verbal information was positively associated with left hippocampal volume, whereas learning curve and retention of non-verbal information was positively associated with right hippocampal volume. Findings support the link between episodic memory and hippocampal volumes in a memory clinic population. Non-verbal memory measures also may have higher diagnostic value, particularly in individuals at elevated risk for Alzheimer's disease.
40 CFR 60.393 - Performance test and compliance provisions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... volume of applied solids emitted after the control device, by the following equation: N=G[1-FE] (A... month by the following equation: EC16NO91.031 (v) If the volume weighted average mass of VOC per volume...
Learner-Centered Instruction (LCI). Volume 5. Description of the Job Performance Test.
ERIC Educational Resources Information Center
Pieper, William J.; And Others
An account is presented of the development of a job performance test for the Learner Centered Instruction (LCI) weapon control systems mechanic/technician Air Force course. The performance test was administered to the LCI experimental course subjects as well as the control course subjects upon graduation. Test items are, for the most part, based…
Hoogendam, Yoo Young; van der Lijn, Fedde; Vernooij, Meike W; Hofman, Albert; Niessen, Wiro J; van der Lugt, Aad; Ikram, M Arfan; van der Geest, Jos N
2014-01-01
In a population-based study of 1,912 community-dwelling persons of 45 years and older, we investigated the relation between age and fine motor skills using the Archimedes spiral-drawing test. Also, we studied the effect of brain volume on fine motor skills. Participants were required to trace a template of a spiral on an electronic drawing board. Clinical scores from this test were obtained by visual assessment of the drawings. Quantitative measures were objectively determined from the recorded data of the drawings. As tremor is known to occur increasingly with advancing age, we also rated drawings to assess presence of tremor. We found presence of a tremor in 1.3% of the drawings. In the group without tremor, we found that older age was related to worse fine motor skills. Additionally, participants over the age of 75 showed increasing deviations from the template when drawing the spiral. Larger cerebral volume and smaller white matter lesion volume were related to better spiral-drawing performance, whereas cerebellar volume was not related to spiral-drawing performance. Older age is related to worse fine motor skills, which can be captured by clinical scoring or quantitative measures of the Archimedes spiral-drawing test. Persons with a tremor performed worse on almost all measures of the spiral-drawing test. Furthermore, larger cerebral volume is related to better fine motor skills.
42 CFR 493.643 - Fee for determination of program compliance.
Code of Federal Regulations, 2010 CFR
2010-10-01
... laboratory's scope and volume of testing (excluding tests performed for quality control, quality assurance... procedure or examination for a single analyte. (Tests performed for quality control, quality assurance, and... HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS General Administration...
Single-breath diffusing capacity for carbon monoxide instrument accuracy across 3 health systems.
Hegewald, Matthew J; Markewitz, Boaz A; Wilson, Emily L; Gallo, Heather M; Jensen, Robert L
2015-03-01
Measuring diffusing capacity of the lung for carbon monoxide (DLCO) is complex and associated with wide intra- and inter-laboratory variability. Increased D(LCO) variability may have important clinical consequences. The objective of the study was to assess instrument performance across hospital pulmonary function testing laboratories using a D(LCO) simulator that produces precise and repeatable D(LCO) values. D(LCO) instruments were tested with CO gas concentrations representing medium and high range D(LCO) values. The absolute difference between observed and target D(LCO) value was used to determine measurement accuracy; accuracy was defined as an average deviation from the target value of < 2.0 mL/min/mm Hg. Accuracy of inspired volume measurement and gas sensors were also determined. Twenty-three instruments were tested across 3 healthcare systems. The mean absolute deviation from the target value was 1.80 mL/min/mm Hg (range 0.24-4.23) with 10 of 23 instruments (43%) being inaccurate. High volume laboratories performed better than low volume laboratories, although the difference was not significant. There was no significant difference among the instruments by manufacturers. Inspired volume was not accurate in 48% of devices; mean absolute deviation from target value was 3.7%. Instrument gas analyzers performed adequately in all instruments. D(LCO) instrument accuracy was unacceptable in 43% of devices. Instrument inaccuracy can be primarily attributed to errors in inspired volume measurement and not gas analyzer performance. D(LCO) instrument performance may be improved by regular testing with a simulator. Caution should be used when comparing D(LCO) results reported from different laboratories. Copyright © 2015 by Daedalus Enterprises.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arnold, G.; Nelson, S.; Cooperrider, N.K.
1982-02-11
This report, Volume II, contains the results, conclusions, and recommendations of the first performance test of a transit care on the RDU. This report is limited to performance tests. The objective is to identify advantages and disadvantages of performance testing on the rollers of the RDU as highlighted by the SOAC test. The report involved separate testing, done by TTC personnel, in such traditional performance areas of transit vehicle operation ass traction, acceleration/deceleration, energy consumption, and spin/slide performance. The results of the successful performance test of a transit car on a roller unit is presented and the advantages of thismore » method of testing is discussed. Acceleration, deceleration, spin/slide, and power consumption tests, although of limited scope in comparison to the track tests performed on the same transit car, did show the feasibility of roller testing. It is concluded that the RDU is most suited for developmental testing of transit car systems particularly for power consumption and for cars with non-standard wheel gage. Tests should be of such scope as to justify the cost of car setup on the RDU. The following two test are recommended: (1) a power consumption study for a standard/non-standard gage transit car which investigates methods of reducing power consumption and (2) a non-standard gage full performance test.« less
Hippocampal Region-Specific Contributions to Memory Performance in Normal Elderly
ERIC Educational Resources Information Center
Chen, Karren H. M.; Chuah, Lisa Y. M.; Sim, Sam K. Y.; Chee, Michael W. L.
2010-01-01
To investigate the relationship between regional hippocampal volume and memory in healthy elderly, 147 community-based volunteers, aged 55-83 years, were evaluated using magnetic resonance imaging, the Groton Maze Learning Test, Visual Reproduction and the Rey Auditory Verbal Learning Test. Hippocampal volumes were determined by interactive…
Mengoli, Carlo; Springer, Jan; Bretagne, Stéphane; Cuenca-Estrella, Manuel; Klingspor, Lena; Lagrou, Katrien; Melchers, Willem J. G.; Morton, C. Oliver; Barnes, Rosemary A.; Donnelly, J. Peter; White, P. Lewis
2015-01-01
The use of serum or plasma for Aspergillus PCR testing facilitates automated and standardized technology. Recommendations for serum testing are available, and while serum and plasma are regularly considered interchangeable for use in fungal diagnostics, differences in galactomannan enzyme immunoassay (GM-EIA) performance have been reported and are attributed to clot formation. Therefore, it is important to assess plasma PCR testing to determine if previous recommendations for serum are applicable and also to compare analytical performance with that of serum PCR. Molecular methods testing serum and plasma were compared through multicenter distribution of quality control panels, with additional studies to investigate the effect of clot formation and blood fractionation on DNA availability. Analytical sensitivity and time to positivity (TTP) were compared, and a regression analysis was performed to identify variables that enhanced plasma PCR performance. When testing plasma, sample volume, preextraction-to-postextraction volume ratio, PCR volume, duplicate testing, and the use of an internal control for PCR were positively associated with performance. When whole-blood samples were spiked and then fractionated, the analytical sensitivity and TTP were superior when testing plasma. Centrifugation had no effect on DNA availability, whereas the presence of clot material significantly lowered the concentration (P = 0.028). Technically, there are no major differences in the molecular processing of serum and plasma, but the formation of clot material potentially reduces available DNA in serum. During disease, Aspergillus DNA burdens in blood are often at the limits of PCR performance. Using plasma might improve performance while maintaining the methodological simplicity of serum testing. PMID:26085614
Loeffler, Juergen; Mengoli, Carlo; Springer, Jan; Bretagne, Stéphane; Cuenca-Estrella, Manuel; Klingspor, Lena; Lagrou, Katrien; Melchers, Willem J G; Morton, C Oliver; Barnes, Rosemary A; Donnelly, J Peter; White, P Lewis
2015-09-01
The use of serum or plasma for Aspergillus PCR testing facilitates automated and standardized technology. Recommendations for serum testing are available, and while serum and plasma are regularly considered interchangeable for use in fungal diagnostics, differences in galactomannan enzyme immunoassay (GM-EIA) performance have been reported and are attributed to clot formation. Therefore, it is important to assess plasma PCR testing to determine if previous recommendations for serum are applicable and also to compare analytical performance with that of serum PCR. Molecular methods testing serum and plasma were compared through multicenter distribution of quality control panels, with additional studies to investigate the effect of clot formation and blood fractionation on DNA availability. Analytical sensitivity and time to positivity (TTP) were compared, and a regression analysis was performed to identify variables that enhanced plasma PCR performance. When testing plasma, sample volume, preextraction-to-postextraction volume ratio, PCR volume, duplicate testing, and the use of an internal control for PCR were positively associated with performance. When whole-blood samples were spiked and then fractionated, the analytical sensitivity and TTP were superior when testing plasma. Centrifugation had no effect on DNA availability, whereas the presence of clot material significantly lowered the concentration (P = 0.028). Technically, there are no major differences in the molecular processing of serum and plasma, but the formation of clot material potentially reduces available DNA in serum. During disease, Aspergillus DNA burdens in blood are often at the limits of PCR performance. Using plasma might improve performance while maintaining the methodological simplicity of serum testing. Copyright © 2015 Loeffler et al.
ERIC Educational Resources Information Center
Simpson, Bruce; And Others
These performance tests for the area of allied health occupations/practical nursing consist of a sampling technique (domain referenced tests) which covers all the possible performance situations. When used in total, they may also serve as a comprehensive test. Introductory materials discuss domain referenced testing, determining the domains, and…
Automobile driver on-road performance test. Volume 1, final report
DOT National Transportation Integrated Search
1981-09-30
The Automobile Driver On-Road Performance Test (ADOPT) was developed during a three-phase project. In Phase 1, 51 candidate behaviors were identified and selected with the help of experts in the fields of traffic safety, measurement of driver perform...
40 CFR 60.285a - Test methods and procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... performance test. (b) The owner or operator must determine compliance with the filterable particulate matter... used to determine the filterable particulate matter concentration. The sampling time and sample volume... repeat performance tests for filterable particulate matter at intervals no longer than 5 years following...
Physiologic and anti-G suit performance data from YF-16 flight tests
NASA Technical Reports Server (NTRS)
Gillingham, K. K.; Winter, W. R.
1976-01-01
Biomedical data were collected during high-G portions of 11 YF-16 test flights. Test pilots monitored revealed increased respiratory rate and volume, decreased tidal volume, and increased heart rate at higher G levels, with one pilot exhibiting various cardiac arrhythmias. Anti-G suit inflation and pressurization lags varied inversely with G-onset rate, and suit pressurization slope was near the design value.
Performance characteristics of a low-volume PM10 sampler
USDA-ARS?s Scientific Manuscript database
Four identical PM10 pre-separators, along with four identical low-volume (1m3 hr-1) total suspended particulate (TSP) samplers were tested side-by-side in a controlled laboratory particulate matter (PM) chamber. The four PM10 and four TSP samplers were also tested in an oil pipe-cleaning field to ev...
DOT National Transportation Integrated Search
2001-06-01
Volume 2 documents laboratory and field testing that provides the evidence that microdamage healing is real and measurable and that it has a significant impact on pavement performance. Part of the laboratory experiments to evaluate the impact of rest...
NASA Non-Flow-Through PEM Fuel Cell System for Aerospace Applications
NASA Technical Reports Server (NTRS)
Araghi, Koorosh R.
2011-01-01
NASA is researching passive NFT Proton Exchange Membrane (PEM) fuel cell technologies for primary fuel cell power plants in air-independent applications. NFT fuel cell power systems have a higher power density than flow through systems due to both reduced parasitic loads and lower system mass and volume. Reactant storage still dominates system mass/volume considerations. NFT fuel cell stack testing has demonstrated equivalent short term performance to flow through stacks. More testing is required to evaluate long-term performance.
Stelmokas, Julija; Yassay, Lance; Giordani, Bruno; Dodge, Hiroko H.; Dinov, Ivo D.; Bhaumik, Arijit; Sathian, K.; Hampstead, Benjamin M.
2018-01-01
NeuroQuant (NQ) is a fully-automated program that overcomes several existing limitations in the clinical translation of MRI-derived volumetry. The current study characterized differences between the original (NQ1) and an updated NQ version (NQ2) by (i) replicating previously identified relationships between neuropsychological test performance and medial temporal lobe volumes, (ii) evaluating the level of agreement between NQ versions, and (iii) determining if the addition of NQ2 age-/sex-based z-scores hold greater clinical utility for prediction of memory impairment than standard percent of intracranial volume (%ICV) values. Sixty-seven healthy older adults and 65 MCI patients underwent structural MRI and completed cognitive testing, including the Immediate and Delayed Memory indices from the RBANS. Results generally replicated previous relationships between key medial temporal lobe regions and memory test performance, though comparison of NQ regions revealed statistically different values that were biased toward one version or the other depending on the region. NQ2 hippocampal z-scores explained additional variance in memory performance relative to %ICV values. Findings indicate that NQ1/2 medial temporal lobe volumes, especially age- and sex-based z-scores, hold clinical value, though caution is warranted when directly comparing volumes across NQ versions. PMID:29060939
ERIC Educational Resources Information Center
Watkins, James F.; And Others
These performance tests for the area of transportation/automotive mechanics consist of a sampling technique (domain referenced tests) which covers all the possible performance situations. When used in total, they may also serve as a comprehensive test. Introductory materials discuss domain referenced testing, determining the domains, and…
Hoogendam, Yoo Young; van der Lijn, Fedde; Vernooij, Meike W.; Hofman, Albert; Niessen, Wiro J.; van der Lugt, Aad; Ikram, M. Arfan; van der Geest, Jos N.
2014-01-01
Introduction: In a population-based study of 1,912 community-dwelling persons of 45 years and older, we investigated the relation between age and fine motor skills using the Archimedes spiral-drawing test. Also, we studied the effect of brain volume on fine motor skills. Methods: Participants were required to trace a template of a spiral on an electronic drawing board. Clinical scores from this test were obtained by visual assessment of the drawings. Quantitative measures were objectively determined from the recorded data of the drawings. As tremor is known to occur increasingly with advancing age, we also rated drawings to assess presence of tremor. Results: We found presence of a tremor in 1.3% of the drawings. In the group without tremor, we found that older age was related to worse fine motor skills. Additionally, participants over the age of 75 showed increasing deviations from the template when drawing the spiral. Larger cerebral volume and smaller white matter lesion volume were related to better spiral-drawing performance, whereas cerebellar volume was not related to spiral-drawing performance. Conclusion: Older age is related to worse fine motor skills, which can be captured by clinical scoring or quantitative measures of the Archimedes spiral-drawing test. Persons with a tremor performed worse on almost all measures of the spiral-drawing test. Furthermore, larger cerebral volume is related to better fine motor skills. PMID:25309436
DOT National Transportation Integrated Search
2012-10-01
The main objective of this study was to determine the effect on bond performance : of high-volume fly ash (HVFA) concrete. The HVFA concrete test program consisted of : comparing the bond performance of two concrete mix designs with 70% cement : repl...
Advanced Actuation Systems Development. Volume 2
1989-08-01
and unloaded performance characteristics of a test specimen produced by General Dynamics Corporation as a feasibility model. The actuation system for...changing the camber of the test specimen is unique and was evaluated with a series of input/output measurements. The testing verified the general ...MAWS General ’rest Procedure........................................6 General Performance Measurements .................................... 10 Test
ILS Glide Slope Performance Prediction. Volume B
1974-09-01
figures are identical in both volumes. . Abottec A mathematical model for predicting the performance of ILS glide slope arrays in the presence of...irregularities on the performance of ILS Glide Slope antenna systems, a mathematical -electromagnetic scattering computer model has been developed. This work was...Antenna ........... 4-4 9. Test Case Results ..................................... r-3 ix PART I. IEO -j 1.INTRODUCTION IA mathematical model has been
Wibmer, Thomas; Rüdiger, Stefan; Kropf-Sanchen, Cornelia; Stoiber, Kathrin M; Rottbauer, Wolfgang; Schumann, Christian
2014-11-01
There is growing evidence that exercise-induced variation in lung volumes is an important source of ventilatory limitation and is linked to exercise intolerance in COPD. The aim of this study was to compare the correlations of walk distance and lung volumes measured before and after a 6-min walk test (6MWT) in subjects with COPD. Forty-five subjects with stable COPD (mean pre-bronchodilator FEV1: 47 ± 18% predicted) underwent a 6MWT. Body plethysmography was performed immediately pre- and post-6MWT. Correlations were generally stronger between 6-min walk distance and post-6MWT lung volumes than between 6-min walk distance and pre-6MWT lung volumes, except for FEV1. These differences in Pearson correlation coefficients were significant for residual volume expressed as percent of total lung capacity (-0.67 vs -0.58, P = .043), percent of predicted residual volume expressed as percent of total lung capacity (-0.68 vs -0.59, P = .026), inspiratory vital capacity (0.65 vs 0.54, P = .019), percent of predicted inspiratory vital capacity (0.49 vs 0.38, P = .037), and percent of predicted functional residual capacity (-0.62 vs -0.47, P = .023). In subjects with stable COPD, lung volumes measured immediately after 6MWT are more closely related to exercise limitation than baseline lung volumes measured before 6MWT, except for FEV1. Therefore, pulmonary function testing immediately after exercise should be included in future studies on COPD for the assessment of exercise-induced ventilatory constraints to physical performance that cannot be adequately assessed from baseline pulmonary function testing at rest. Copyright © 2014 by Daedalus Enterprises.
40 CFR 60.433 - Performance test and compliance provisions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... indicating the cumulative liquid volumes used at each affected facility; or (ii) Segregated storage tanks for... related coatings measured as used by volume with different amounts of VOC content or different densities. n is the total number of raw inks and related coatings measured as used by volume with different...
40 CFR 60.463 - Performance test and compliance provisions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... operator shall use the following procedures for determining monthly volume-weighted average emissions of... Method 24 or an equivalent or alternative method. The owner or operator shall determine the volume of... facilities, the owner or operator shall estimate the volume of coating used at each affected facility by...
40 CFR 60.453 - Performance test and compliance provisions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... determine the volume of coating and the mass of VOC-solvent used for thinning purposes from company records... serves both affected and existing facilities, the owner or operator shall estimate the volume of coatings... per unit volume of coating solids applied each calendar month will be determined as follows. (A...
40 CFR 60.313 - Performance tests and compliance provisions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... determining monthly volume-weighted average emissions of VOC's in kilograms per liter of coating solids... shall determine the volume of coating and the mass of VOC-solvent used for thinning purposes from... facility or serves both affected and existing facilities, the owner or operator shall estimate the volume...
The volume of sediment required to perform a sediment toxicity bioassay is a major driver of the overall cost associated with that bioassay. Sediment volume affects bioassay cost due to sediment collection, transportation, storage, and disposal costs as well as labor costs assoc...
Griffith, H Randall; Stewart, Christopher C; Stoeckel, Luke E; Okonkwo, Ozioma C; den Hollander, Jan A; Martin, Roy C; Belue, Katherine; Copeland, Jacquelynn N; Harrell, Lindy E; Brockington, John C; Clark, David G; Marson, Daniel C
2010-02-01
To better understand how brain atrophy in amnestic mild cognitive impairment (MCI) as measured using magnetic resonance imaging (MRI) volumetrics could affect instrumental activities of daily living (IADLs) such as financial abilities. Controlled, matched-sample, cross-sectional analysis regressing MRI volumetrics with financial performance measures. University medical and research center. Thirty-eight people with MCI and 28 older adult controls. MRI volumetric measurement of the hippocampi, angular gyri, precunei, and medial frontal lobes. Participants also completed neuropsychological tests and the Financial Capacity Instrument (FCI). Correlations were performed between FCI scores and MRI volumes in the group with MCI. People with MCI performed significantly below controls on the FCI and had significantly smaller hippocampi. Among people with MCI, performance on the FCI was moderately correlated with angular gyri and precunei volumes. Regression models demonstrated that angular gyrus volumes were predictive of FCI scores. Tests of mediation showed that measures of arithmetic and possibly attention partially mediated the relationship between angular gyrus volume and FCI score. Impaired financial abilities in amnestic MCI correspond with volume of the angular gyri as mediated by arithmetic knowledge. The findings suggest that early neuropathology within the lateral parietal region in MCI leads to a breakdown of cognitive abilities that affect everyday financial skills. The findings have implications for diagnosis and clinical care of people with MCI and AD.
Design and testing a high fuel volume fraction, externally finned, thermionic emitter.
NASA Technical Reports Server (NTRS)
Peelgren, M. L.; Ernst, D. M.
1971-01-01
A prototypical, high fuel volume fraction, thermionic emitter body was designed and tested. The emitter body is all tungsten, with a 1.40-cm ID, a 3.23-cm OD, and eight full-length axial fins. The emitter thickness is 0.15 cm while the fins and outer clad are 0.075 cm thick. Different methods of fabrication were used in making the test samples. Stress analysis was performed with a three-dimensional elastic code. Thermal testing of the samples, duplicating calculated radial temperature gradients, heatup and cooldown rates, and emitter body temperatures in operation, was performed with no structural failures noted (six heatup and cooldown cycles per sample). Further emitter analysis and testing is planned.
DOT National Transportation Integrated Search
1979-02-01
The SLRV (Standard Light Rail Vehicle) is a 71-foot vehicle, articulated to negotiate curves down to 32-foot radius and designed to operate at speeds up to 50 mph. Although the basic configuration and performance is standardized, the current operatin...
DOT National Transportation Integrated Search
1999-04-01
The purpose of this study is to crash test and evaluate new or modified roadside safety hardware and, where necessary, redesign the devices to improve their impact performance. The three major areas addressed in this study are the impact performance ...
Urine monitoring system failure analysis and operational verification test report
NASA Technical Reports Server (NTRS)
Glanfield, E. J.
1978-01-01
Failure analysis and testing of a prototype urine monitoring system (UMS) are reported. System performance was characterized by a regression formula developed from volume measurement test data. When the volume measurement test data. When the volume measurement data was imputted to the formula, the standard error of the estimate calculated using the regression formula was found to be within 1.524% of the mean of the mass of the input. System repeatability was found to be somewhat dependent upon the residual volume of the system and the evaporation of fluid from the separator. The evaporation rate was determined to be approximately 1cc/minute. The residual volume in the UMS was determined by measuring the concentration of LiCl in the flush water. Observed results indicated residual levels in the range of 9-10ml, however, results obtained during the flushing efficiency test indicated a residual level of approximately 20ml. It is recommended that the phase separator pumpout time be extended or the design modified to minimize the residual level.
The performance of the Shirco pilot-scale infrared thermal destruction system has been evaluated at the Rose Township, Demode Road Superfund Site and is presented in the report. The waste tested consisted of solvents, organics and heavy metals in an illegal dump site. Volume I gi...
Skalleberg, A G; Bouzga, M M
2016-07-01
In 2009, the Norwegian police academy educated their first crime scene dogs, trained to locate traces of seminal fluid and blood in outdoor and indoor crime scenes. The Department of Forensic Biology was invited to take part in this project to educate the police in specimen collection and presumptive testing. We performed tests where seminal fluid was deposited on different outdoor surfaces from between one hour to six days, and blood on coniferous ground from between one hour to two days. For both body fluids the tests were performed with three different volumes. The crime scene dogs located the stains, and acid phosphatase/tetrabasebariumperoxide was used as presumptive tests before collection for microscopy and DNA analysis. For seminal fluid the dogs were able to locate all stains for up to two days and only the largest volume after four days. The presumptive tests confirmed the dog's detection. By microscopy we were able to detect spermatozoa for the smallest volumes up to 32h, and for the largest volume up to 4 days, and the DNA results are in correlation to these findings. For blood all the stains were detected by the dogs, except the smallest volume of blood after 32h. The presumptive tests confirmed the dog's detection. We were able to get DNA results for most stains in the timeframe 1-48h with the two largest volumes. The smallest volume shows diversities between the parallels, with no DNA results after 24h. These experiments show that it is critical that body fluids are collected within a timeframe to be able to get a good DNA result, preferably within the first 24-48h. Other parameters that should be taken into account are the weather conditions, type of surfaces and specimen collection. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
CD volume design and verification
NASA Technical Reports Server (NTRS)
Li, Y. P.; Hughes, J. S.
1993-01-01
In this paper, we describe a prototype for CD-ROM volume design and verification. This prototype allows users to create their own model of CD volumes by modifying a prototypical model. Rule-based verification of the test volumes can then be performed later on against the volume definition. This working prototype has proven the concept of model-driven rule-based design and verification for large quantity of data. The model defined for the CD-ROM volumes becomes a data model as well as an executable specification.
DOT National Transportation Integrated Search
2015-01-01
This report is the second of three volumes and presents detailed data and test summaries of the experimental portion of the work. In total : 30 large scale reinforced concrete bridge columns are reported in this volume. Recommendations for design and...
40 CFR 60.493 - Performance test and compliance provisions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... equivalent or alternative method. The owner or operator shall determine from company records the volume of... estimate the volume of coating used at each facility by using the average dry weight of coating, number of... acceptable to the Administrator. (i) Calculate the volume-weighted average of the total mass of VOC per...
Lung volumes during sustained microgravity on Spacelab SLS-1
NASA Technical Reports Server (NTRS)
Elliott, Ann R.; Prisk, Gordon Kim; Guy, Harold J. B.; West, John B.
1994-01-01
Gravity is known to influence the topographical gradients of pulmonary ventilation, perfusion, and pleural pressures. The effect of sustained microgravity on lung volumes has not previously been investigated. Pulmonary function tests were performed by four subjects before, during, and after 9 days of microgravity exposure. Ground measurements were made in standing and supine postures. Tests were performed using a bag-in-box and flowmeter system and a respiratory mass spectrometer. Measurements of tidal volume (V(sub T)), expiratory reserve volume (ERV), inspiratory and expiratory vital capacities (IVC, EVC), functional residual capacity (FRC), and residual volume (RV) were made. During microgravity, V(sub T) decreased by 15%. IVC and EVC were slightly reduced during the first 24 hrs of microgravity and returned to 1 g standing values within 72 hrs after the onset of microgravity. FRC was reduced by 15% and ERV decreased by 10-20%. RV was significantly reduced by 18%. The reductions in FRC, ERV, and V(sub T) during microgravity are probably due to the cranial shift of the diaphragm and an increase in intrathoracic blood volume.
NASA Technical Reports Server (NTRS)
1979-01-01
The performance test results of the final under-the-wing engine configuration are presented. One hundred and six hours of engine operation were completed, including mechanical and performance checkout, baseline acoustic testing with a bellmouth inlet, reverse thrust testing, acoustic technology tests, and limited controls testing. The engine includes a variable pitch fan having advanced composite fan blades and using a ball-spline pitch actuation system.
Eltoum, Isam A; Roberson, Janie
2007-02-25
The frequently cited number of 50 million annual Papanicolaou cervical screening (Pap) tests performed in the US was based on the National Health Interview Survey (NHIS) of the 1980s. Since then, monumental changes have occurred. More change will soon follow when primary human papilloma virus (HPV) testing and/or HPV vaccine delivery are fully accepted and implemented. The objectives of this study were 1) to estimate the total annual Pap tests performed in the US based on recent NHIS surveys, and 2) to estimate the potential change in the total annual Pap volume produced by changing demographics, reduced screening frequency, HPV testing, and the HPV vaccine. In the NHIS 2000 and NHIS 2005, women were asked to report the frequency of their Pap tests for the 6 years prior to the interview and to report whether they had abnormal findings. The authors analyzed the survey respondents answers to these questions by using SAS Survey Procedures (SAS Institute, NC). The results were stratified by age, and the total national volume was then extrapolated from a similarly stratified 2000 US census. The projected increase of total Pap tests for the next 25 years was determined by using the projected census data. Potential reductions of Pap tests performed secondarily to HPV testing of women >30 years old and of HPV vaccination were also determined. Based on NHIS 2000 and NHIS 2005, 66 million (95% CI, 65-68) and 65 million (95% CI, 64-67) Pap tests were performed in the US, respectively. Had HPV testing been performed in women older than 30 years who had both negative HPV and negative 3-year Pap tests, then 30% (95% CI, 29-32%) of Pap tests would not have been performed. If both HPV testing and vaccination are performed, the total number of Pap tests performed annually is predicted to be reduced by 43% (95% CI, 35-38%). Therefore, despite an expected increase in the population of women eligible for Pap tests, the total number will likely decrease substantially in the future. This, in turn, will decrease the demand for a traditionally trained cytotechnology workforce. (c) 2007 American Cancer Society.
NASA Technical Reports Server (NTRS)
Tobey, G. L.
1978-01-01
Tests were performed to evaluate the operating characteristics of the interface between the Space Lab Bus Interface Unit (SL/BIU) and the Orbiter Multiplexer-Demultiplexer (MDM) serial data input-output (SIO) module. This volume contains the test equipment preparation procedures and a detailed description of the Nova/Input Output Processor Simulator (IOPS) software used during the data transfer tests to determine word error rates (WER).
Force properties of skinned cardiac muscle following increasing volumes of aerobic exercise in rats.
Boldt, Kevin Rudi; Rios, Jaqueline Lourdes; Joumaa, Venus; Herzog, Walter
2018-05-03
The positive effects of chronic endurance exercise training on health and performance have been well documented. These positive effects have been evaluated primarily at the structural level, and work has begun to evaluate mechanical adaptations of the myocardium. However, it remains poorly understood how the volume of exercise training affects cardiac adaptation. In order to gain some understanding, we subjected three-month-old Sprague-Dawley rats (N=23) to treadmill running for eleven weeks at one of three exercise volumes (moderate, high, and extra high). Following training, hearts were excised and mechanical testing was completed on skinned trabecular fiber bundles. Performance on a maximal fitness test was dose-dependent upon training volume, where greater levels of training led to greater performance. No differences were observed between animals from any group for active stress production. Heart mass and passive stress increases in a dose-dependent manner for animals in the control, moderate, and high duration groups. However, hearts from animals in the extra high duration group presented with inhibited responses for heart mass and passive stress, despite performing greatest on a graded treadmill fitness test. These results suggest that heart mass and passive stress adapt in a dose-dependent manner, until exercise becomes excessive and adaptation is inhibited. Our findings are in agreement with the beneficial role exercise has in cardiac adaptation. However, excessive exercise comes with risks of maladaptation which must be weighed against the desire to increase performance.
Stelmokas, Julija; Yassay, Lance; Giordani, Bruno; Dodge, Hiroko H; Dinov, Ivo D; Bhaumik, Arijit; Sathian, K; Hampstead, Benjamin M
2017-01-01
NeuroQuant (NQ) is a fully-automated program that overcomes several existing limitations in the clinical translation of MRI-derived volumetry. The current study characterized differences between the original (NQ1) and an updated NQ version (NQ2) by 1) replicating previously identified relationships between neuropsychological test performance and medial temporal lobe volumes, 2) evaluating the level of agreement between NQ versions, and 3) determining if the addition of NQ2 age-/sex-based z-scores hold greater clinical utility for prediction of memory impairment than standard percent of intracranial volume (% ICV) values. Sixty-seven healthy older adults and 65 mild cognitive impairment patients underwent structural MRI and completed cognitive testing, including the Immediate and Delayed Memory indices from the Repeatable Battery for the Assessment of Neuropsychological Status. Results generally replicated previous relationships between key medial temporal lobe regions and memory test performance, though comparison of NQ regions revealed statistically different values that were biased toward one version or the other depending on the region. NQ2 hippocampal z-scores explained additional variance in memory performance relative to % ICV values. Findings indicate that NQ1/2 medial temporal lobe volumes, especially age- and sex-based z-scores, hold clinical value, though caution is warranted when directly comparing volumes across NQ versions.
Solar cell array design handbook, volume 1
NASA Technical Reports Server (NTRS)
Rauschenbach, H. S.
1976-01-01
Twelve chapters discuss the following: historical developments, the environment and its effects, solar cells, solar cell filters and covers, solar cell and other electrical interconnections, blocking and shunt diodes, substrates and deployment mechanisms, material properties, design synthesis and optimization, design analysis, procurement, production and cost aspects, evaluation and test, orbital performance, and illustrative design examples. A comprehensive index permits rapid locating of desired topics. The handbook consists of two volumes: Volume 1 is of an expository nature while Volume 2 contains detailed design data in an appendix-like fashion. Volume 2 includes solar cell performance data, applicable unit conversion factors and physical constants, and mechanical, electrical, thermal optical, magnetic, and outgassing material properties. Extensive references are provided.
Testing of state roadside safety systems. Volume I, Technical report
DOT National Transportation Integrated Search
1999-04-01
The purpose of this study is to crash test and evaluate new or modified roadside safety hardware and, where necessary, redesign the devices to improve their impact performance. The three major areas addressed in this study are the impact performance ...
Herbst, Daniel P
2014-09-01
Micropore filters are used during extracorporeal circulation to prevent gaseous and solid particles from entering the patient's systemic circulation. Although these devices improve patient safety, limitations in current designs have prompted the development of a new concept in micropore filtration. A prototype of the new design was made using 40-μm filter screens and compared against four commercially available filters for performance in pressure loss and gross air handling. Pre- and postfilter bubble counts for 5- and 10-mL bolus injections in an ex vivo test circuit were recorded using a Doppler ultrasound bubble counter. Statistical analysis of results for bubble volume reduction between test filters was performed with one-way repeated-measures analysis of variance using Bonferroni post hoc tests. Changes in filter performance with changes in microbubble load were also assessed with dependent t tests using the 5- and 10-mL bolus injections as the paired sample for each filter. Significance was set at p < .05. All filters in the test group were comparable in pressure loss performance, showing a range of 26-33 mmHg at a flow rate of 6 L/min. In gross air-handling studies, the prototype showed improved bubble volume reduction, reaching statistical significance with three of the four commercial filters. All test filters showed decreased performance in bubble volume reduction when the microbubble load was increased. Findings from this research support the underpinning theories of a sequential arterial-line filter design and suggest that improvements in microbubble filtration may be possible using this technique.
Herbst, Daniel P.
2014-01-01
Abstract: Micropore filters are used during extracorporeal circulation to prevent gaseous and solid particles from entering the patient’s systemic circulation. Although these devices improve patient safety, limitations in current designs have prompted the development of a new concept in micropore filtration. A prototype of the new design was made using 40-μm filter screens and compared against four commercially available filters for performance in pressure loss and gross air handling. Pre- and postfilter bubble counts for 5- and 10-mL bolus injections in an ex vivo test circuit were recorded using a Doppler ultrasound bubble counter. Statistical analysis of results for bubble volume reduction between test filters was performed with one-way repeated-measures analysis of variance using Bonferroni post hoc tests. Changes in filter performance with changes in microbubble load were also assessed with dependent t tests using the 5- and 10-mL bolus injections as the paired sample for each filter. Significance was set at p < .05. All filters in the test group were comparable in pressure loss performance, showing a range of 26–33 mmHg at a flow rate of 6 L/min. In gross air-handling studies, the prototype showed improved bubble volume reduction, reaching statistical significance with three of the four commercial filters. All test filters showed decreased performance in bubble volume reduction when the microbubble load was increased. Findings from this research support the underpinning theories of a sequential arterial-line filter design and suggest that improvements in microbubble filtration may be possible using this technique. PMID:26357790
Kerbler, Georg M.; Nedelska, Zuzana; Fripp, Jurgen; Laczó, Jan; Vyhnalek, Martin; Lisý, Jiří; Hamlin, Adam S.; Rose, Stephen; Hort, Jakub; Coulson, Elizabeth J.
2015-01-01
The basal forebrain degenerates in Alzheimer’s disease (AD) and this process is believed to contribute to the cognitive decline observed in AD patients. Impairment in spatial navigation is an early feature of the disease but whether basal forebrain dysfunction in AD is responsible for the impaired navigation skills of AD patients is not known. Our objective was to investigate the relationship between basal forebrain volume and performance in real space as well as computer-based navigation paradigms in an elderly cohort comprising cognitively normal controls, subjects with amnestic mild cognitive impairment and those with AD. We also tested whether basal forebrain volume could predict the participants’ ability to perform allocentric- vs. egocentric-based navigation tasks. The basal forebrain volume was calculated from 1.5 T magnetic resonance imaging (MRI) scans, and navigation skills were assessed using the human analog of the Morris water maze employing allocentric, egocentric, and mixed allo/egocentric real space as well as computerized tests. When considering the entire sample, we found that basal forebrain volume correlated with spatial accuracy in allocentric (cued) and mixed allo/egocentric navigation tasks but not the egocentric (uncued) task, demonstrating an important role of the basal forebrain in mediating cue-based spatial navigation capacity. Regression analysis revealed that, although hippocampal volume reflected navigation performance across the entire sample, basal forebrain volume contributed to mixed allo/egocentric navigation performance in the AD group, whereas hippocampal volume did not. This suggests that atrophy of the basal forebrain contributes to aspects of navigation impairment in AD that are independent of hippocampal atrophy. PMID:26441643
Distinct neuroanatomical bases of episodic and semantic memory performance in Alzheimer's disease.
Hirni, Daniela I; Kivisaari, Sasa L; Monsch, Andreas U; Taylor, Kirsten I
2013-04-01
Alzheimer's disease (AD) neurofibrillary pathology begins in the medial perirhinal cortex (mPRC) before spreading to the entorhinal cortex (ERC) and hippocampus (HP) in anterior medial temporal lobe (aMTL). While the role of the ERC/HP complex in episodic memory formation is well-established, recent research suggests that the PRC is required to form semantic memories of individual objects. We aimed to test whether commonly used clinical measures of episodic and semantic memory are distinctly associated with ERC/HP and mPRC integrity, respectively, in healthy mature individuals and very early AD patients. One hundred thirty normal controls, 32 amnestic mild cognitive impairment patients, some of whom are in the earliest (i.e., preclinical) stages of AD, and ten early-stage AD patients received neuropsychological testing and high-resolution anatomic and diffusion MRI. Voxel-based regression analyses tested for regions where episodic memory (delayed recall scores on the California Verbal Learning and Rey Osterrieth Complex Figure Tests) and semantic memory (Boston Naming Test, category fluency) performance correlated with gray matter (GM) regions of interest and whole-brain fractional anisotropy (FA) voxel values. When controlling for the opposing memory performance, poorer episodic memory performance was associated with reduced bilateral ERC/HP GM volume and related white matter integrity, but not with mPRC GM volume. Poor semantic memory performance was associated with both reduced left mPRC and ERC/HP GM volume, as well as reduced FA values in white matter tracts leading to the PRC. These results indicate a partial division of labor within the aMTL and suggest that mPRC damage in very early AD may be detectable with common clinical tests of semantic memory if episodic memory performance is controlled. Copyright © 2013 Elsevier Ltd. All rights reserved.
Han, Jeong-Hwan; Oda, Takuji
2018-04-14
The performance of exchange-correlation functionals in density-functional theory (DFT) calculations for liquid metal has not been sufficiently examined. In the present study, benchmark tests of Perdew-Burke-Ernzerhof (PBE), Armiento-Mattsson 2005 (AM05), PBE re-parameterized for solids, and local density approximation (LDA) functionals are conducted for liquid sodium. The pair correlation function, equilibrium atomic volume, bulk modulus, and relative enthalpy are evaluated at 600 K and 1000 K. Compared with the available experimental data, the errors range from -11.2% to 0.0% for the atomic volume, from -5.2% to 22.0% for the bulk modulus, and from -3.5% to 2.5% for the relative enthalpy depending on the DFT functional. The generalized gradient approximation functionals are superior to the LDA functional, and the PBE and AM05 functionals exhibit the best performance. In addition, we assess whether the error tendency in liquid simulations is comparable to that in solid simulations, which would suggest that the atomic volume and relative enthalpy performances are comparable between solid and liquid states but that the bulk modulus performance is not. These benchmark test results indicate that the results of liquid simulations are significantly dependent on the exchange-correlation functional and that the DFT functional performance in solid simulations can be used to roughly estimate the performance in liquid simulations.
NASA Astrophysics Data System (ADS)
Han, Jeong-Hwan; Oda, Takuji
2018-04-01
The performance of exchange-correlation functionals in density-functional theory (DFT) calculations for liquid metal has not been sufficiently examined. In the present study, benchmark tests of Perdew-Burke-Ernzerhof (PBE), Armiento-Mattsson 2005 (AM05), PBE re-parameterized for solids, and local density approximation (LDA) functionals are conducted for liquid sodium. The pair correlation function, equilibrium atomic volume, bulk modulus, and relative enthalpy are evaluated at 600 K and 1000 K. Compared with the available experimental data, the errors range from -11.2% to 0.0% for the atomic volume, from -5.2% to 22.0% for the bulk modulus, and from -3.5% to 2.5% for the relative enthalpy depending on the DFT functional. The generalized gradient approximation functionals are superior to the LDA functional, and the PBE and AM05 functionals exhibit the best performance. In addition, we assess whether the error tendency in liquid simulations is comparable to that in solid simulations, which would suggest that the atomic volume and relative enthalpy performances are comparable between solid and liquid states but that the bulk modulus performance is not. These benchmark test results indicate that the results of liquid simulations are significantly dependent on the exchange-correlation functional and that the DFT functional performance in solid simulations can be used to roughly estimate the performance in liquid simulations.
NASA Astrophysics Data System (ADS)
Baum, K.; Essfeld, D.; Stegemann, J.
To investigate the effect of μg-induced peripheral extracellular fluid reductions on heart rate and blood pressure during isometric exercise, six healthy male subjects performed three calf ergometer test with different extracellular volumes of working muscles. In all tests, body positions during exercise were identical (supine with the knee joint flexed to 900). After a pre-exercise period of 25 min, during which calf volumes were manipulated, subjects had to counteract an external force of 180 N for 5 min. During the pre-exercise period three different protocols were applied. Test A: Subjects rested in the exercise position; test B: Body position was the same as in A but calf volume was increased by venous congestion (cuffs inflated to 80 mm Hg); test C: Calf volumes were decreased by a negative hydrostatic pressure (calves about 40 cm above heart level with the subjects supine). To clamp the changed calf volumes in tests B and C, cuffs were inflated to 300 mm Hg 5 min before the onset of exercise. This occlusion was maintained until termination of exercise. Compared to tests A and B, the reduced volume of test C led to significant increases in heart rate and blood pressure during exercise. Oxygen uptake did not exceed resting levels in B and C until cuffs were deflated, indicating that exclusively calf muscles contributed to the neurogenic peripheral drive. It is concluded that changes in extracellular muscle volume have to be taken into account when comparing heart rate and blood pressure during lg- and μg- exercise.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Volume VIII of the documentation for the Phase I Data Analysis Task performed in support of the current Regional Flow Model, Transport Model, and Risk Assessment for the Nevada Test Site Underground Test Area Subproject contains the risk assessment documentation. Because of the size and complexity of the model area, a considerable quantity of data was collected and analyzed in support of the modeling efforts. The data analysis task was consequently broken into eight subtasks, and descriptions of each subtask's activities are contained in one of the eight volumes that comprise the Phase I Data Analysis Documentation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Volume VII of the documentation for the Phase I Data Analysis Task performed in support of the current Regional Flow Model, Transport Model, and Risk Assessment for the Nevada Test Site Underground Test Area Subproject contains the tritium transport model documentation. Because of the size and complexity of the model area, a considerable quantity of data was collected and analyzed in support of the modeling efforts. The data analysis task was consequently broken into eight subtasks, and descriptions of each subtask's activities are contained in one of the eight volumes that comprise the Phase I Data Analysis Documentation.
Detailed requirements document for the Interactive Financial Management System (IFMS), volume 1
NASA Technical Reports Server (NTRS)
Dodson, D. B.
1975-01-01
The detailed requirements for phase 1 (online fund control, subauthorization accounting, and accounts receivable functional capabilities) of the Interactive Financial Management System (IFMS) are described. This includes information on the following: systems requirements, performance requirements, test requirements, and production implementation. Most of the work is centered on systems requirements, and includes discussions on the following processes: resources authority, allotment, primary work authorization, reimbursable order acceptance, purchase request, obligation, cost accrual, cost distribution, disbursement, subauthorization performance, travel, accounts receivable, payroll, property, edit table maintenance, end-of-year, backup input. Other subjects covered include: external systems interfaces, general inquiries, general report requirements, communication requirements, and miscellaneous. Subjects covered under performance requirements include: response time, processing volumes, system reliability, and accuracy. Under test requirements come test data sources, general test approach, and acceptance criteria. Under production implementation come data base establishment, operational stages, and operational requirements.
Validation of Test Weighing Protocol to Estimate Enteral Feeding Volumes in Preterm Infants.
Rankin, Michael W; Jimenez, Elizabeth Yakes; Caraco, Marina; Collinson, Marie; Lostetter, Lisa; DuPont, Tara L
2016-11-01
To evaluate the accuracy of pre- and postfeeding weights to estimate enteral feeding volumes in preterm infants. Single-center prospective cohort study of infants 28-36 weeks' corrected age receiving gavage feedings. For each test weight, 3 pre- and 3 postgavage feeding weights were obtained by study personnel, blinded to feeding volume, via a specific protocol. The correlation between test weight difference and actual volume ingested was assessed by the use of summary statistics, Spearman rho, and graphical analyses. The relationship between categorical predictive variables and a predefined acceptable difference (±5 mL) was assessed with the χ 2 or Fisher exact test. A total of 101 test weights were performed in 68 infants. Estimated and actual feeding volumes were highly correlated (r = 0.94, P < .001), with a mean absolute difference of 2.95 mL (SD: 2.70; range: 0, 12.3 mL; 5th, 95th percentile: 0, 9.3); 85% of test weights were within ±5 mL of actual feeding volume and did not vary significantly by corrected age, feeding tube or respiratory support type, feeding duration or volume, formula vs breast milk, or caloric density. With adherence to study protocol, 89% of test weights (66/74) were within ±5 mL of actual volume, compared with 71% (19/27, P = .04) when concerns about protocol adherence were noted (eg, difficulty securing oxygen tubing). Via the use of a standard protocol, feeding volumes can be estimated accurately by pre- and postfeeding weights. Test weighing could be a valuable tool to support direct breastfeeding in the neonatal intensive care unit. Copyright © 2016 Elsevier Inc. All rights reserved.
40 CFR 60.393 - Performance test and compliance provisions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... per volume of applied coating solids (G) during each calendar month for each affected facility by the following equation: EC16NO91.030 (E) For each EDP prime coat operation, calculate the turnover ratio (RT) by....392(a). (ii) If the volume weighted average mass of VOC per volume of applied coating solids (G...
Study of Abrasive Wear Volume Map for PTFE and PTFE Composites
NASA Astrophysics Data System (ADS)
Unal, H.; Sen, U.; Mimaroglu, A.
2007-11-01
The potential of this work is based on consideration of wear volume map for the evaluation of abrasive wear performance of polytetrafluoroethylene (PTFE) and PTFE composites. The fillers used in the composite are 25% bronze, 35% graphite and 17% glass fibre glass (GFR). The influence of filler materials, abrasion surface roughness and applied load values on abrasive wear performance of PTFE and PTFE composites were studied and evaluated. Experimental abrasive wear tests were carried out at atmospheric condition on pin-on-disc wear tribometer. Tests were performed under 4, 6, 8 and 10 N load values, travelling speed of 1 m/sec and abrasion surface roughness values of 5, 20 and 45 µm. Wear volume maps were obtained and the results showed that the lowest wear volume rate for PTFE is reached using GFR filler. Furthermore, the results also showed that the higher is the applied load and the roughness of the abrasion surface, the higher is the wear rate. Finally it is also concluded that abrasive wear process mechanism include ploughing and cutting mechanisms.
Arlt, Sönke; Buchert, Ralph; Spies, Lothar; Eichenlaub, Martin; Lehmbeck, Jan T; Jahn, Holger
2013-06-01
Fully automated magnetic resonance imaging (MRI)-based volumetry may serve as biomarker for the diagnosis in patients with mild cognitive impairment (MCI) or dementia. We aimed at investigating the relation between fully automated MRI-based volumetric measures and neuropsychological test performance in amnestic MCI and patients with mild dementia due to Alzheimer's disease (AD) in a cross-sectional and longitudinal study. In order to assess a possible prognostic value of fully automated MRI-based volumetry for future cognitive performance, the rate of change of neuropsychological test performance over time was also tested for its correlation with fully automated MRI-based volumetry at baseline. In 50 subjects, 18 with amnestic MCI, 21 with mild AD, and 11 controls, neuropsychological testing and T1-weighted MRI were performed at baseline and at a mean follow-up interval of 2.1 ± 0.5 years (n = 19). Fully automated MRI volumetry of the grey matter volume (GMV) was performed using a combined stereotactic normalisation and segmentation approach as provided by SPM8 and a set of pre-defined binary lobe masks. Left and right hippocampus masks were derived from probabilistic cytoarchitectonic maps. Volumes of the inner and outer liquor space were also determined automatically from the MRI. Pearson's test was used for the correlation analyses. Left hippocampal GMV was significantly correlated with performance in memory tasks, and left temporal GMV was related to performance in language tasks. Bilateral frontal, parietal and occipital GMVs were correlated to performance in neuropsychological tests comprising multiple domains. Rate of GMV change in the left hippocampus was correlated with decline of performance in the Boston Naming Test (BNT), Mini-Mental Status Examination, and trail making test B (TMT-B). The decrease of BNT and TMT-A performance over time correlated with the loss of grey matter in multiple brain regions. We conclude that fully automated MRI-based volumetry allows detection of regional grey matter volume loss that correlates with neuropsychological performance in patients with amnestic MCI or mild AD. Because of the high level of automation, MRI-based volumetry may easily be integrated into clinical routine to complement the current diagnostic procedure.
Konheim, Jeremy A; Kon, Zachary N; Pasrija, Chetan; Luo, Qingyang; Sanchez, Pablo G; Garcia, Jose P; Griffith, Bartley P; Jeudy, Jean
2016-04-01
Size matching for lung transplantation is widely accomplished using height comparisons between donors and recipients. This gross approximation allows for wide variation in lung size and, potentially, size mismatch. Three-dimensional computed tomography (3D-CT) volumetry comparisons could offer more accurate size matching. Although recipient CT scans are universally available, donor CT scans are rarely performed. Therefore, predicted donor lung volumes could be used for comparison to measured recipient lung volumes, but no such predictive equations exist. We aimed to use 3D-CT volumetry measurements from a normal patient population to generate equations for predicted total lung volume (pTLV), predicted right lung volume (pRLV), and predicted left lung volume (pLLV), for size-matching purposes. Chest CT scans of 400 normal patients were retrospectively evaluated. 3D-CT volumetry was performed to measure total lung volume, right lung volume, and left lung volume of each patient, and predictive equations were generated. The fitted model was tested in a separate group of 100 patients. The model was externally validated by comparison of total lung volume with total lung capacity from pulmonary function tests in a subset of those patients. Age, gender, height, and race were independent predictors of lung volume. In the test group, there were strong linear correlations between predicted and actual lung volumes measured by 3D-CT volumetry for pTLV (r = 0.72), pRLV (r = 0.72), and pLLV (r = 0.69). A strong linear correlation was also observed when comparing pTLV and total lung capacity (r = 0.82). We successfully created a predictive model for pTLV, pRLV, and pLLV. These may serve as reference standards and predict donor lung volume for size matching in lung transplantation. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
1976-06-01
rotating stall control system which was tested both on a low speed rig and a J-85-S engine. The second objective was to perform fundamental studies of the...Stator Stage 89 6 Annular Cascade Configuration Used for Rotating Stall Studies on Rotoi-Stator Stage ..... .............. ... 90 7 Static Pressure Rise...ground tests on a J-8S-S turbojet engine. The work i3 reported in three separate volumes. Volume I entitled, "Basic Studies of Rotating Stall", covers
Gas permeability measurements for film envelope materials
Ludtka, G.M.; Kollie, T.G.; Watkin, D.C.; Walton, D.G.
1998-05-12
Method and apparatus for measuring the permeability of polymer film materials such as used in super-insulation powder-filled evacuated panels (PEPs) reduce the time required for testing from several years to weeks or months. The method involves substitution of a solid non-outgassing body having a free volume of between 0% and 25% of its total volume for the usual powder in the PEP to control the free volume of the ``body-filled panel.`` Pressure versus time data for the test piece permit extrapolation to obtain long term performance of the candidate materials. 4 figs.
Gas permeability measurements for film envelope materials
Ludtka, Gerard M.; Kollie, Thomas G.; Watkin, David C.; Walton, David G.
1998-01-01
Method and apparatus for measuring the permeability of polymer film materials such as used in super-insulation powder-filled evacuated panels (PEPs) reduce the time required for testing from several years to weeks or months. The method involves substitution of a solid non-outgassing body having a free volume of between 0% and 25% of its total volume for the usual powder in the PEP to control the free volume of the "body-filled panel". Pressure versus time data for the test piece permit extrapolation to obtain long term performance of the candidate materials.
Pfützner, Andreas; Schipper, Christina; Ramljak, Sanja; Flacke, Frank; Sieber, Jochen; Forst, Thomas; Musholt, Petra B
2013-11-01
Accuracy of blood glucose readings is (among other things) dependent on the test strip being completely filled with sufficient sample volume. The devices are supposed to display an error message in case of incomplete filling. This laboratory study was performed to test the performance of 31 commercially available devices in case of incomplete strip filling. Samples with two different glucose levels (60-90 and 300-350 mg/dl) were used to generate three different sample volumes: 0.20 µl (too low volume for any device), 0.32 µl (borderline volume), and 1.20 µl (low but supposedly sufficient volume for all devices). After a point-of-care capillary reference measurement (StatStrip, NovaBiomedical), the meter strip was filled (6x) with the respective volume, and the response of the meters (two devices) was documented (72 determinations/meter type). Correct response was defined as either an error message indicating incomplete filling or a correct reading (±20% compared with reference reading). Only five meters showed 100% correct responses [BGStar and iBGStar (both Sanofi), ACCU-CHEK Compact+ and ACCU-CHEK Mobile (both Roche Diagnostics), OneTouch Verio (LifeScan)]. The majority of the meters (17) had up to 10% incorrect reactions [predominantly incorrect readings with sufficient volume; Precision Xceed and Xtra, FreeStyle Lite, and Freedom Lite (all Abbott); GlucoCard+ and GlucoMen GM (both Menarini); Contour, Contour USB, and Breeze2 (all Bayer); OneTouch Ultra Easy, Ultra 2, and Ultra Smart (all LifeScan); Wellion Dialog and Premium (both MedTrust); FineTouch (Terumo); ACCU-CHEK Aviva (Roche); and GlucoTalk (Axis-Shield)]. Ten percent to 20% incorrect reactions were seen with OneTouch Vita (LifeScan), ACCU-CHEK Aviva Nano (Roche), OmniTest+ (BBraun), and AlphaChek+ (Berger Med). More than 20% incorrect reactions were obtained with Pura (Ypsomed), GlucoCard Meter and GlucoMen LX (both Menarini), Elite (Bayer), and MediTouch (Medisana). In summary, partial and incomplete blood filling of glucose meter strips is often associated with inaccurate reading. These findings underline the importance of appropriate patient education on this aspect of blood glucose self-monitoring. © 2013 Diabetes Technology Society.
NASA Technical Reports Server (NTRS)
Stewart, V. R.
1987-01-01
A propulsive wind/canard model was tested at STOL operating conditions in the NASA Langley Research Center 4 x 7 meter wind tunnel. Longitudinal and lateral/directional aerodynamic characteristics were measured for various flap deflections, angles of attack and sideslip, and blowing coefficients. Testing was conducted for several model heights to determine ground proximity effects on the aerodynamic characteristics. Flow field surveys of local flow angles and velocities were performed behind both the canard and the wing. This is volume 2 of a 2 volume report. All of the test data in three appendices are presented. Appendix A presented tabulated six component force and moment data, Appendix B presents tabulated wing pressure coefficients, and Appendix C presents the flow field data.
ERIC Educational Resources Information Center
Shriver, Edgar L.; And Others
This volume reports an effort to use the video media as an approach for the preparation of a battery of symbolic tests that would be empirically valid substitutes for criterion referenced Job Task Performance Tests. The graphic symbolic tests require the storage of a large amount of pictorial information which must be searched rapidly for display.…
Gelen, Ertugrul; Dede, Muhittin; Bingul, Bergun Meric; Bulgan, Cigdem; Aydin, Mensure
2012-01-01
The purpose of this study was to compare the acute effects of static stretching; dynamic exercises and high volume upper extremity plyometric activity on tennis serve performance. Twenty-six elite young tennis players (15.1 ± 4.2 years, 167.9 ± 5.8 cm and 61.6 ± 8.1 kg) performed 4 different warm-up (WU) routines in a random order on non-consecutive days. The WU methods consisted of traditional WU (jogging, rally and serve practice) (TRAD); traditional WU and static stretching (TRSS); traditional WU and dynamic exercise (TRDE); and traditional WU and high volume upper extremity plyometric activity (TRPLYP). Following each WU session, subjects were tested on a tennis serve ball speed test. TRAD, TRSS, TRDE and TRPLYO were compared by repeated measurement analyses of variance and post-hoc comparisons. In this study a 1 to 3 percent increase in tennis serve ball speed was recorded in TRDE and TRPLYO when compared to TRAD (p< 0.05). However, no significant change in ball speed performance between TRSS and TRAD. (p> 0.05). ICCs for ball speed showed strong reliability (0.82 to 0.93) for the ball speed measurements.The results of this study indicate that dynamic and high volume upper extremity plyometric WU activities are likely beneficial to serve speed of elite junior tennis players. Key points After the traditional warm up in tennis, static stretching has no effect on serve speed. Tennis players should perform dynamic exercises and/or high volume upper extremity plyometric activities to improve their athletic performance. PMID:24150068
Study of cavitating inducer instabilities
NASA Technical Reports Server (NTRS)
Young, W. E.; Murphy, R.; Reddecliff, J. M.
1972-01-01
An analytic and experimental investigation into the causes and mechanisms of cavitating inducer instabilities was conducted. Hydrofoil cascade tests were performed, during which cavity sizes were measured. The measured data were used, along with inducer data and potential flow predictions, to refine an analysis for the prediction of inducer blade suction surface cavitation cavity volume. Cavity volume predictions were incorporated into a linearized system model, and instability predictions for an inducer water test loop were generated. Inducer tests were conducted and instability predictions correlated favorably with measured instability data.
40 CFR Table 2 to Subpart Dddd of... - Model Rule-Emission Limitations
Code of Federal Regulations, 2011 CFR
2011-07-01
... this part) Carbon monoxide 157 parts per million by dry volume 3-run average (1 hour minimum sample... per million by dry volume 3-run average (1 hour minimum sample time per run) Performance test (Method... appendix A of this part) Oxides of nitrogen 388 parts per million by dry volume 3-run average (1 hour...
Jones, Bruce A; Darcy, Teresa; Souers, Rhona J; Meier, Frederick A
2012-02-01
Publicly available information concerning laboratory staffing benchmarks is scarce. One of the few publications on this topic summarized the findings of a Q-Probes study performed in 2004. This publication reports a similar survey with data collected in 2010. To assess the relationship between staffing levels in specified laboratory sections and test volumes in these sections and quantify management span of control. The study defined 4 laboratory sections: anatomic pathology (including cytology), chemistry/hematology/immunology, microbiology, and transfusion medicine. It divided staff into 3 categories: management, nonmanagement (operational or bench staff), and doctoral (MD, PhD) supervisory staff. People in these categories were tabulated as full-time equivalents and exclusions specified. Tests were counted in uniform formats, specified for each laboratory section, according to Medicare rules for the bundling and unbundling of tests. Ninety-eight participating institutions provided data that showed significant associations between test volumes and staffing for all 4 sections. There was wide variation in productivity based on volume. There was no relationship between testing volume per laboratory section and management span of control. Higher productivity in chemistry/hematology/immunology was associated with a higher fraction of tests coming from nonacute care patients. In both the 2004 and 2010 studies, productivity was inseparably linked to test volume. Higher test volume was associated with higher productivity ratios in chemistry/hematology/immunology and transfusion medicine sections. The impact of various testing services on productivity is section-specific.
DOT National Transportation Integrated Search
2006-05-01
This research study, sponsored by the Federal Highway Administration, summarizes the field performance of eight high-early-strength (HES) : concrete patches between 1994 and 1998. The patches were constructed under the Strategic Highway Research Prog...
NASA Technical Reports Server (NTRS)
Hawkins-Reynolds, Ebony; Le,Hung; Stephans, Ryan A.
2009-01-01
Minimizing mass and volume is critically important for space hardware. Microchannel technology can be used to decrease both of these parameters for heat exchangers. Working in concert with NASA, Pacific Northwest National Laboratories (PNNL) has developed a microchannel liquid/liquid heat exchanger that has resulted in significant mass and volume savings. The microchannel heat exchanger delivers these improvements without sacrificing thermal and pressure drop performance. A conventional heat exchanger has been tested and the performance of it recorded to compare it to the microchannel heat exchanger that PNNL has fabricated. The microchannel heat exchanger was designed to meet all of the requirements of the baseline heat exchanger, while reducing the heat exchanger mass and volume. The baseline heat exchanger was designed to have an transfer approximately 3.1 kW for a specific set of inlet conditions. The baseline heat exchanger mass was 2.7 kg while the microchannel mass was only 2.0 kg. More impressive, however, was the volumetric savings associated with the microchannel heat exchanger. The microchannel heat exchanger was an order of magnitude smaller than the baseline heat exchanger (2180cm3 vs. 311 cm3). This paper will describe the test apparatus designed to complete performance tests for both heat exchangers. Also described in this paper will be the performance specifications for the microchannel heat exchanger and how they compare to the baseline heat exchanger.
Correlation of neurocognitive function and brain parenchyma volumes in children surviving cancer
NASA Astrophysics Data System (ADS)
Reddick, Wilburn E.; White, Holly A.; Glass, John O.; Mulhern, Raymond K.
2002-04-01
This research builds on our hypothesis that white matter damage and associated neurocognitive symptoms, in children treated for cancer with cranial spinal irradiation, spans a continuum of severity that can be reliably probed using non-invasive MR technology. Quantitative volumetric assessments of MR imaging and psychological assessments were obtained in 40 long-term survivors of malignant brain tumors treated with cranial irradiation. Neurocognitive assessments included a test of intellect (Wechsler Intelligence Test for Children, Wechsler Adult Intelligence Scale), attention (Conner's Continuous Performance Test), and memory (California Verbal Learning Test). One-sample t-tests were conducted to evaluate test performance of survivors against age-adjusted scores from the test norms; these analyses revealed significant impairments in all apriori selected measures of intelligence, attention, and memory. Partial correlation analyses were performed to assess the relationships between brain tissues volumes (normal appearing white matter (NAWM), gray matter, and CSF) and neurocognitive function. Global intelligence (r = 0.32, p = 0.05) and global attentional (r = 0.49, p < 0.01) were significantly positively correlated with NAWM volumes, whereas global memory was significantly positively correlated with overall brain parenchyma (r = 0.38, p = 0.04). We conclude that quantitative assessment of MR examinations in survivors of childhood cancer treated with cranial irradiation reveal that loss of NAWM is associated with decreased intellectual and attentional deficits, whereas overall parenchyma loss, as reflected by increased CSF and decreased white matter, is associated with memory-related deficits.
Kahle, Jason T.; Klenow, Tyler D.; Highsmith, M. Jason
2016-01-01
The socket-limb interface is vital for functionality and provides stability and mobility for the amputee. Volume fluctuation can lead to compromised fit and function. Current socket technology does not accommodate for volume fluctuation. An adjustable interface may improve function and comfort by filling this technology gap. The purpose of this study was to compare the effectiveness of the standard of care (SOC) ischial ramus containment to an adjustable transfemoral prosthetic interface socket in the accommodation of volume fluctuation. A prospective experimental case study using repeated measures of subjective and performance outcome measures between socket conditions was employed. In the baseline volume condition, the adjustable socket improved subjective and performance measures 19% to 37% over SOC, whereas the two-minute walk test demonstrated equivalence. In the volume loss condition, the adjustable socket improved all subjective and performance measures 22% to 93%. All aggregated data improved 16% to 50% compared with the SOC. In simulated volume gain, the SOC socket failed, while the subject was able to complete the protocol using the adjustable socket. In this case study, the SOC socket was inferior to the comparative adjustable transfemoral amputation interface in subjective and performance outcomes. There is a lack of clinical trials and evidence comparing socket functional outcomes related to volume fluctuation. PMID:28066526
Phase 2 Site Investigations Report. Volume 3 of 3: Appendices
1994-09-01
Phase II Site Investigations Ee Report Cn Volume III of III Appendices Fort Devens Sudbury Training Annex, Massachusetts September 1994 Contract No...laboratory quality control (QC) samples collected during field investigations at the Sudbury Training Annex of Fort Devens , Massachusetts. The QC...returned to its original condition. E & E performed this procedure for each monitoring well tested during the 1993 slug testing activities at Fort Devens
Single passenger rail car impact test. Volume III, Test procedures, instrumentation and data.
DOT National Transportation Integrated Search
2000-01-12
A full-scale impact test was performed November 16, 1999, at the Federal Railroad Administrations Transportation : Technology Center, Pueblo, Colorado, by Transportation Technology Center, Inc., a subsidiary of the Association of : American Railro...
NASA Astrophysics Data System (ADS)
Molz, F. J.; Melville, J. G.; Gueven, O.; Parr, A. D.
1983-09-01
In March 1980 Auburn University began a series of aquifer thermal energy storage (ATES) experiments using the doublet well configuration. The test site was in Mobile, Alabama. The objectives of the three experimental cycles were to demonstrate the technical feasibility of the ATES concept, to identify and resolve operational problems, and to acquire a data base for developing and testing mathematical models. Pre-injection tests were performed and analyses of hydraulic, geochemical, and thermodynamic data were completed. Three injection-storage-recovery cycles had injection volumes of 25,402 m(3), 58,010 m(3), and 58,680 m(3) and average injection temperatures of 58.50C, 81.00C. and 79.00C, respectively. The first cycle injection began in February 1981 and the third cycle recovery was completed in November 1982. Attributable to the doublet well configuration no clogging of injection wells occurred. Energy recovery percentages based on recovery volumes equal to the injection volumes were 56, 45, and 42%. Thermal convection effects were observed. Aquifer nonhomogeneity, not detectable using standard aquifer testing procedures, was shown to reduce recovery efficiency.
Freedman, Barry I; Sink, Kaycee M; Hugenschmidt, Christina E; Hughes, Timothy M; Williamson, Jeff D; Whitlow, Christopher T; Palmer, Nicholette D; Miller, Michael E; Lovato, Laura C; Xu, Jianzhao; Smith, S Carrie; Launer, Lenore J; Barzilay, Joshua I; Cohen, Robert M; Sullivan, Mark D; Bryan, R Nick; Wagner, Benjamin C; Bowden, Donald W; Maldjian, Joseph A; Divers, Jasmin
2017-11-01
Relationships between early kidney disease, neurocognitive function, and brain anatomy are poorly defined in African Americans with type 2 diabetes mellitus (T2DM). Cross-sectional associations were assessed between cerebral anatomy and cognitive performance with estimated glomerular filtration rate (eGFR) and urine albumin-creatinine ratio (UACR) in African Americans with T2DM. African Americans with cognitive testing and cerebral magnetic resonance imaging (MRI) in the African American-Diabetes Heart Study Memory in Diabetes (AA-DHS MIND; n=512; 480 with MRI) and Action to Control Cardiovascular Risk in Diabetes (ACCORD) MIND (n=484; 104 with MRI) studies. eGFR (CKD-EPI creatinine equation), spot UACR. MRI-based cerebral white matter volume (WMV), gray matter volume (GMV), and white matter lesion volume; cognitive performance (Mini-Mental State Examination, Digit Symbol Coding, Stroop Test, and Rey Auditory Verbal Learning Test). Multivariable models adjusted for age, sex, body mass index, scanner, intracranial volume, education, diabetes duration, hemoglobin A 1c concentration, low-density lipoprotein cholesterol concentration, smoking, hypertension, and cardiovascular disease were used to test for associations between kidney phenotypes and the brain in each study; a meta-analysis was performed. Mean participant age was 60.1±7.9 (SD) years; diabetes duration, 12.1±7.7 years; hemoglobin A 1c concentration, 8.3%±1.7%; eGFR, 88.7±21.6mL/min/1.73m 2 ; and UACR, 119.2±336.4mg/g. In the fully adjusted meta-analysis, higher GMV associated with lower UACR (P<0.05), with a trend toward association with higher eGFR. Higher white matter lesion volume was associated with higher UACR (P<0.05) and lower eGFR (P<0.001). WMV was not associated with either kidney parameter. Higher UACR was associated with lower Digit Symbol Coding performance (P<0.001) and a trend toward association with higher Stroop interference; eGFR was not associated with cognitive tests. Cross-sectional; single UACR measurement. In African Americans with T2DM, mildly high UACR and mildly low eGFR were associated with smaller GMV and increased white matter lesion volume. UACR was associated with poorer processing speed and working memory. Copyright © 2017 National Kidney Foundation, Inc. All rights reserved.
Lee, Donggil; Lee, Kyounghoon; Kim, Seonghun; Yang, Yongsu
2015-04-01
An automatic abalone grading algorithm that estimates abalone weights on the basis of computer vision using 2D images is developed and tested. The algorithm overcomes the problems experienced by conventional abalone grading methods that utilize manual sorting and mechanical automatic grading. To design an optimal algorithm, a regression formula and R(2) value were investigated by performing a regression analysis for each of total length, body width, thickness, view area, and actual volume against abalone weights. The R(2) value between the actual volume and abalone weight was 0.999, showing a relatively high correlation. As a result, to easily estimate the actual volumes of abalones based on computer vision, the volumes were calculated under the assumption that abalone shapes are half-oblate ellipsoids, and a regression formula was derived to estimate the volumes of abalones through linear regression analysis between the calculated and actual volumes. The final automatic abalone grading algorithm is designed using the abalone volume estimation regression formula derived from test results, and the actual volumes and abalone weights regression formula. In the range of abalones weighting from 16.51 to 128.01 g, the results of evaluation of the performance of algorithm via cross-validation indicate root mean square and worst-case prediction errors of are 2.8 and ±8 g, respectively. © 2015 Institute of Food Technologists®
2015-01-01
different PRBC transfusion volumes. We performed multivariate regression analysis using HRV metrics and routine vital signs to test the hypothesis that...study sponsors did not have any role in the study design, data collection, analysis and interpretation of data, report writing, or the decision to...primary outcome was hemorrhagic injury plus different PRBC transfusion volumes. We performed multivariate regression analysis using HRV metrics and
DOT National Transportation Integrated Search
2000-05-24
A full-scale impact test was performed November 16, 1999, at the Federal Railroad Administration's Transportation Technology Center, Pueblo, Colorado, by Transportation Technology Center, Inc., a subsidiary of the Association of American Railroads. T...
Electrical Evaluation of RCA MWS5001D Random Access Memory, Volume 1
NASA Technical Reports Server (NTRS)
Klute, A.
1979-01-01
Electrical characterization and qualification tests were performed on the RCA MWS5001D, 1024 by 1-bit, CMOS, random access memory. Characterization tests were performed on five devices. The tests included functional tests, AC parametric worst case pattern selection test, determination of worst-case transition for setup and hold times and a series of schmoo plots. The qualification tests were performed on 32 devices and included a 2000 hour burn in with electrical tests performed at 0 hours and after 168, 1000, and 2000 hours of burn in. The tests performed included functional tests and AC and DC parametric tests. All of the tests in the characterization phase, with the exception of the worst-case transition test, were performed at ambient temperatures of 25, -55 and 125 C. The worst-case transition test was performed at 25 C. The preburn in electrical tests were performed at 25, -55, and 125 C. All burn in endpoint tests were performed at 25, -40, -55, 85, and 125 C.
Cognitive activity relates to cognitive performance but not to Alzheimer disease biomarkers
Gidicsin, Christopher M.; Maye, Jacqueline E.; Locascio, Joseph J.; Pepin, Lesley C.; Philiossaint, Marlie; Becker, J. Alex; Younger, Alayna P.; Dekhtyar, Maria; Schultz, Aaron P.; Amariglio, Rebecca E.; Marshall, Gad A.; Rentz, Dorene M.; Hedden, Trey; Sperling, Reisa A.
2015-01-01
Objective: We aimed to determine whether there was a relationship between lifestyle factors and Alzheimer disease biomarkers. Methods: In a cross-sectional study, we evaluated self-reported histories of recent and past cognitive activity, self-reported history of recent physical activity, and objective recent walking activity in 186 clinically normal individuals with mean age of 74 ± 6 years. Using backward elimination general linear models, we tested the hypotheses that greater cognitive or physical activity would be associated with lower Pittsburgh compound B–PET retention, greater 18F-fluorodeoxyglucose–PET metabolism, and larger hippocampal volume, as well as better cognitive performance on neuropsychological testing. Results: Linear regression demonstrated that history of greater cognitive activity was correlated with greater estimated IQ and education, as well as better neuropsychological testing performance. Self-reported recent physical activity was related to objective exercise monitoring. However, contrary to hypotheses, we did not find evidence of an association of Pittsburgh compound B retention, 18F-fluorodeoxyglucose uptake, or hippocampal volume with past or current levels of cognitive activity, or with current physical activity. Conclusions: We conclude that a history of lifelong cognitive activity may support better cognitive performance by a mechanism that is independent of brain β-amyloid burden, brain glucose metabolism, or hippocampal volume. PMID:26062627
Cognitive activity relates to cognitive performance but not to Alzheimer disease biomarkers.
Gidicsin, Christopher M; Maye, Jacqueline E; Locascio, Joseph J; Pepin, Lesley C; Philiossaint, Marlie; Becker, J Alex; Younger, Alayna P; Dekhtyar, Maria; Schultz, Aaron P; Amariglio, Rebecca E; Marshall, Gad A; Rentz, Dorene M; Hedden, Trey; Sperling, Reisa A; Johnson, Keith A
2015-07-07
We aimed to determine whether there was a relationship between lifestyle factors and Alzheimer disease biomarkers. In a cross-sectional study, we evaluated self-reported histories of recent and past cognitive activity, self-reported history of recent physical activity, and objective recent walking activity in 186 clinically normal individuals with mean age of 74 ± 6 years. Using backward elimination general linear models, we tested the hypotheses that greater cognitive or physical activity would be associated with lower Pittsburgh compound B-PET retention, greater (18)F-fluorodeoxyglucose-PET metabolism, and larger hippocampal volume, as well as better cognitive performance on neuropsychological testing. Linear regression demonstrated that history of greater cognitive activity was correlated with greater estimated IQ and education, as well as better neuropsychological testing performance. Self-reported recent physical activity was related to objective exercise monitoring. However, contrary to hypotheses, we did not find evidence of an association of Pittsburgh compound B retention, (18)F-fluorodeoxyglucose uptake, or hippocampal volume with past or current levels of cognitive activity, or with current physical activity. We conclude that a history of lifelong cognitive activity may support better cognitive performance by a mechanism that is independent of brain β-amyloid burden, brain glucose metabolism, or hippocampal volume. © 2015 American Academy of Neurology.
Performance oriented guidance for Mississippi chip seals - volume II.
DOT National Transportation Integrated Search
2013-12-01
A laboratory and field study was conducted related to long term chip seal performance. This reports primary : objective was to initiate development of a long term performance (LTP) test protocol for chip seals focused on : aggregate retention. Key...
Memory disorders in probable Alzheimer's disease: the role of hippocampal atrophy as shown with MRI.
Deweer, B; Lehéricy, S; Pillon, B; Baulac, M; Chiras, J; Marsault, C; Agid, Y; Dubois, B
1995-01-01
Magnetic resonance based volumetric measures of hippocampal formation, amygdala (A), caudate nucleus (CN), normalised for total intracranial volume (TIV), were analysed in relation to measures of cognitive deterioration and specific features of memory functions in 18 patients with probable Alzheimer's disease. Neuropsychological examination included the mini mental state examination (MMSE), the Mattis dementia rating scale (DRS), tests of executive functions, assessment of language abilities and praxis, the Wechsler memory scale (WMS), the California verbal learning test (CVLT) and the Grober and Buschke test. The volume of the hippocampal formation (HF/TIV) was correlated with specific memory variables: memory quotient and paired associates of the WMS; intrusions and discriminability at recognition for the Grober and Buschke test. By contrast, except for intrusions, no correlations were found between memory variables and the volume of amygdala (A/TIV). No correlations were found between the volume of caudate nuclei (CN/TIV) and any neuropsychological score. The volume of the hippocampal formation was therefore selectively related to quantitative and qualitative aspects of memory performance in patients with probable Alzheimer's disease. Images PMID:7745409
40 CFR 63.6620 - What performance tests and other procedures must I use?
Code of Federal Regulations, 2011 CFR
2011-07-01
... based on the ratio of oxygen volume to the ultimate CO2 volume produced by the fuel at zero percent... volume of CO2 produced to the gross calorific value of the fuel from Method 19, dsm3/J (dscf/106 Btu... equivalent percent carbon dioxide (CO2). If pollutant concentrations are to be corrected to 15 percent oxygen...
40 CFR 63.6620 - What performance tests and other procedures must I use?
Code of Federal Regulations, 2012 CFR
2012-07-01
... based on the ratio of oxygen volume to the ultimate CO2 volume produced by the fuel at zero percent... volume of CO2 produced to the gross calorific value of the fuel from Method 19, dsm3/J (dscf/106 Btu... equivalent percent carbon dioxide (CO2). If pollutant concentrations are to be corrected to 15 percent oxygen...
Evaluation of Aspergillus PCR protocols for testing serum specimens.
White, P Lewis; Mengoli, Carlo; Bretagne, Stéphane; Cuenca-Estrella, Manuel; Finnstrom, Niklas; Klingspor, Lena; Melchers, Willem J G; McCulloch, Elaine; Barnes, Rosemary A; Donnelly, J Peter; Loeffler, Juergen
2011-11-01
A panel of human serum samples spiked with various amounts of Aspergillus fumigatus genomic DNA was distributed to 23 centers within the European Aspergillus PCR Initiative to determine analytical performance of PCR. Information regarding specific methodological components and PCR performance was requested. The information provided was made anonymous, and meta-regression analysis was performed to determine any procedural factors that significantly altered PCR performance. Ninety-seven percent of protocols were able to detect a threshold of 10 genomes/ml on at least one occasion, with 83% of protocols reproducibly detecting this concentration. Sensitivity and specificity were 86.1% and 93.6%, respectively. Positive associations between sensitivity and the use of larger sample volumes, an internal control PCR, and PCR targeting the internal transcribed spacer (ITS) region were shown. Negative associations between sensitivity and the use of larger elution volumes (≥100 μl) and PCR targeting the mitochondrial genes were demonstrated. Most Aspergillus PCR protocols used to test serum generate satisfactory analytical performance. Testing serum requires less standardization, and the specific recommendations shown in this article will only improve performance.
Evaluation of Aspergillus PCR Protocols for Testing Serum Specimens▿†
White, P. Lewis; Mengoli, Carlo; Bretagne, Stéphane; Cuenca-Estrella, Manuel; Finnstrom, Niklas; Klingspor, Lena; Melchers, Willem J. G.; McCulloch, Elaine; Barnes, Rosemary A.; Donnelly, J. Peter; Loeffler, Juergen
2011-01-01
A panel of human serum samples spiked with various amounts of Aspergillus fumigatus genomic DNA was distributed to 23 centers within the European Aspergillus PCR Initiative to determine analytical performance of PCR. Information regarding specific methodological components and PCR performance was requested. The information provided was made anonymous, and meta-regression analysis was performed to determine any procedural factors that significantly altered PCR performance. Ninety-seven percent of protocols were able to detect a threshold of 10 genomes/ml on at least one occasion, with 83% of protocols reproducibly detecting this concentration. Sensitivity and specificity were 86.1% and 93.6%, respectively. Positive associations between sensitivity and the use of larger sample volumes, an internal control PCR, and PCR targeting the internal transcribed spacer (ITS) region were shown. Negative associations between sensitivity and the use of larger elution volumes (≥100 μl) and PCR targeting the mitochondrial genes were demonstrated. Most Aspergillus PCR protocols used to test serum generate satisfactory analytical performance. Testing serum requires less standardization, and the specific recommendations shown in this article will only improve performance. PMID:21940479
NASA Technical Reports Server (NTRS)
1978-01-01
Sea level, static, ground testing of the over-the-wing engine and boilerplate nacelle components was performed. The equipment tested and the test facility are described. Summaries of the instrumentations, the chronological history of the tests, and the test results are presented.
DOT National Transportation Integrated Search
1977-05-01
The primary purpose of the tests documented herein was to demonstrate the principles and feasibility of an energy-storage-type propulsion system, and its adaptability to an existing car design. The test program comprised four phases of tests on two N...
Ramírez-Campillo, Rodrigo; Henríquez-Olguín, Carlos; Burgos, Carlos; Andrade, David C; Zapata, Daniel; Martínez, Cristian; Álvarez, Cristian; Baez, Eduardo I; Castro-Sepúlveda, Mauricio; Peñailillo, Luis; Izquierdo, Mikel
2015-07-01
The purpose of the study was to compare the effects of progressive volume-based overload with constant volume-based overload on muscle explosive and endurance performance adaptations during a biweekly short-term (i.e., 6 weeks) plyometric training intervention in young soccer players. Three groups of young soccer players (age 13.0 ± 2.3 years) were divided into: control (CG; n = 8) and plyometric training with (PPT; n = 8) and without (NPPT; n = 8) a progressive increase in volume (i.e., 16 jumps per leg per week, with an initial volume of 80 jumps per leg each session). Bilateral and unilateral horizontal and vertical countermovement jump with arms (CMJA), 20-cm drop jump reactive strength index (RSI20), maximal kicking velocity (MKV), 10-m sprint, change of direction speed (CODS), and Yo-Yo intermittent recovery level 1 test (Yo-Yo IR1) were measured. Although both experimental groups significantly increased CMJA, RSI20, CODS, and endurance performance, only PPT showed a significant improvement in MKV and 10-m sprint time. In addition, only PPT showed a significantly higher performance improvement in jumping, MKV, and Yo-Yo IR1 compared with CG. Also, PPT showed higher meaningful improvement compared with NPPT in all (except 1) jump performance measures. Furthermore, although PPT involved a higher total volume compared with NPPT, training efficiency (i.e., percentage change in performance/total jump volume) was similar between groups. Our results show that PPT and NPPT ensured significant improvement in muscle explosive and endurance performance measures. However, a progressive increase in plyometric training volume seems more advantageous to induce soccer-specific performance improvements.
DOT National Transportation Integrated Search
2015-01-01
This report is the first of three volumes and presents interpretation of all experimental and numerical data and recommendations. In : total, 30 large scale reinforced concrete columns tests were conducted under a variety of loading conditions. Using...
Performance of Loblolly Pine Seed Sources in Argentina
Timothy La Farge; Floyd E. Bridgwater; Mirta N. Baez
1999-01-01
Four test series of loblolly pine (Pinus taeda L.) were evaluated to determine the performance in northeastern Argentina of seed sources from three breeding populations in the southeastern United States. Three half-sib progeny tests of seed sources from Florida and Louisiana demonstrated strong genetic gains for height, dbh, and volume growth....
Raytheon RSP2 Cryocooler Low Temperature Testing and Design Enhancements
NASA Astrophysics Data System (ADS)
Hon, R. C.; Kirkconnell, C. S.; Shrago, J. A.
2010-04-01
The High Capacity Raytheon Stirling/Pulse Tube Hybrid 2-Stage cryocooler (HC-RSP2) was originally developed to provide simultaneous cooling at temperatures of 85 K and 35 K. During testing performed in 2008 it was demonstrated that this stock-configuration cryocooler is capable of providing significant amounts of heat lift at 2nd stage temperatures as low as 12 K, and modeling indicated that minor changes to the 2nd stage inertance tube/surge volume setup could yield improved performance. These changes were implemented and the cooler was successfully retested, producing >350 mW of heat lift at 12 K. A comprehensive redesign of the system has been performed, the result of which is a robust 2-stage cryocooler system that is intended to efficiently produce relatively large amounts of cooling at 2nd stage temperatures <12 K. This cryocooler, called the Low Temperature RSP2 (LT-RSP2) will be fabricated and tested over the next 12 months. This paper reports on the recently-completed test activities, as well as details relating to the system redesign. Expected performance, mass and packaging volume are addressed.
Automation of Command and Data Entry in a Glovebox Work Volume: An Evaluation of Data Entry Devices
NASA Technical Reports Server (NTRS)
Steele, Marianne K.; Nakamura, Gail; Havens, Cindy; LeMay, Moira
1996-01-01
The present study was designed to examine the human-computer interface for data entry while performing experimental procedures within a glovebox work volume in order to make a recommendation to the Space Station Biological Research Project for a data entry system to be used within the Life Sciences Glovebox. Test subjects entered data using either a manual keypad, similar to a standard computer numerical keypad located within the glovebox work volume, or a voice input system using a speech recognition program with a microphone headset. Numerical input and commands were programmed in an identical manner between the two systems. With both electronic systems, a small trackball was available within the work volume for cursor control. Data, such as sample vial identification numbers, sample tissue weights, and health check parameters of the specimen, were entered directly into procedures that were electronically displayed on a video monitor within the glovebox. A pen and paper system with a 'flip-chart' format for procedure display, similar to that currently in use on the Space Shuttle, was used as a baseline data entry condition. Procedures were performed by a single operator; eight test subjects were used in the study. The electronic systems were tested under both a 'nominal' or 'anomalous' condition. The anomalous condition was introduced into the experimental procedure to increase the probability of finding limitations or problems with human interactions with the electronic systems. Each subject performed five test runs during a test day: two procedures each with voice and keypad, one with and one without anomalies, and one pen and paper procedure. The data collected were both quantitative (times, errors) and qualitative (subjective ratings of the subjects).
Takai, Daiya
2014-12-01
Spirometry and the flow-volume curve test are commonly performed lung function tests. However, a unique clinical entity occasionally shows almost normal data in these tests, and is therefore missed on screening tests. The clinical entity of combined pulmonary emphysema and pulmdoary fibrosis was recognized and documented in the 90's in Japan, the USA, and Europe. Typical emphysema shows obstructive disorders, and pulmonary fibrosis shows restrictive disorders. Thus, the combination of both should lead to a combined disorder pattern in lung function tests, but this is not the case. In 2005, Cottin reported and redefined this combination of emphysema and fibrosis of the lung as "Combined Pulmonary Fibrosis and Emphysema" (CPFE). The patients are typically heavily smoking males who show an almost normal lung function. The upper lobe of these patients usually shows severe emphysema, which contributes to a static volume and a late phase in the forced volume test. On the other hand their lower lobe shows fibrotic change. The fibrotic portion contributes to early phase flow in the flow-volume curve. These mechanisms are a reason for the normal pattern appearance in lung function tests in CPFE patients. As a matter of course, these patients have damaged upper and lower lobes: their diffusing capacity of the lung shows a low performance, their saturation of blood hemoglobin decreases soon after light exercise, and their KL-6 (a blood marker of pulmonary fibrosis) usually shows a high value. They are considered a high risk group regarding complications of post-surgical treatment. Thus, when medical technologists identify suspicious cases, they should advise doctors to add diffusing capacity and KL-6 tests. (Review).
NASA Technical Reports Server (NTRS)
Eng, R. D.; Evans, D. J.
1979-01-01
The performance of a hot isotatic pressed disk installed in an experimental engine and exposed to realistic operating conditions in a 150-hour engine test and a 1000 cycle endurance test is documented. Post test analysis, based on visual, fluorescent penetrant and dimensional inspection, revealed no defects in the disk and indicated that the disk performed satisfactorily.
Ørbo, Marte C; Vangberg, Torgil R; Tande, Pål M; Anke, Audny; Aslaksen, Per M
2018-05-01
We explored the associations between global brain volumes, hippocampal subfield volumes and verbal memory performance in long-term survivors of out-of-hospital cardiac arrest (OHCA). Three months after OHCA, survivors and healthy, age-matched controls were assessed with cerebral MRI and the California Verbal Learning Test-II (CVLT-II). Volumetric brain segmentation was performed automatically by FreeSurfer. Twenty-six OHCA survivors who were living independently in regular homes at the time of assessment and 19 controls participated in the study. Thirteen of the survivors had been conscious upon arrival to the emergency department. The other 13 survivors had 0.5-7 days of inpatient coma before recovery. Memory was poorer in the OHCA group that had been comatose beyond initial hospital admission compared to both other groups. Total cortical volumes, total hippocampus volumes and several hippocampal subfield volumes were significantly smaller in the OHCA group comatose beyond initial hospital admission compared to controls. No significant differences between the OHCA group conscious upon emergency department arrival and the other two groups were found for brain volumes. No significant differences were observed between any groups for white matter or total subcortical volumes. In OHCA survivors with recovery from inpatient coma, the various CVLT-II trials were significantly, but differentially, correlated to total gray matter volume, cortical volume and the hippocampal subfield subiculum. In this small, single-site study, both hippocampal volume and cortical volume were smaller in good outcome OHCA survivors 3 months after resuscitation in comparison to healthy controls. Smaller cerebral volumes were correlated with poorer memory performance. Copyright © 2018 Elsevier B.V. All rights reserved.
Advanced blade tip seal system, volume 2
NASA Technical Reports Server (NTRS)
Zelahy, J. W.; Fairbanks, N. P.
1982-01-01
The results of the endurance and performance engine tests conducted on monocrystal/abrasive-tipped CF6-50 Stage 1 HPT blades fabricated in Task VII of MATE Project 3 are presented. Two engine tests are conducted. The endurance engine test is conducted for 1000 C cycles. The performance engine test is conducted on a variable cycle core engine. Posttest evaluation and analyses of the blades and shrouds included visual, dimensional, and destructive evaluations.
Flight test results of the strapdown hexad inertial reference unit (SIRU). Volume 2: Test report
NASA Technical Reports Server (NTRS)
Hruby, R. J.; Bjorkman, W. S.
1977-01-01
Results of flight tests of the Strapdown Inertial Reference Unit (SIRU) navigation system are presented. The fault tolerant SIRU navigation system features a redundant inertial sensor unit and dual computers. System software provides for detection and isolation of inertial sensor failures and continued operation in the event of failures. Flight test results include assessments of the system's navigational performance and fault tolerance. Performance shortcomings are analyzed.
NASA Technical Reports Server (NTRS)
Moore, C. S.; Collins, J. H. Jr
1932-01-01
The clearance distribution in a precombustion chamber cylinder head was varied so that for a constant compression ratio of 13.5 the spherical auxiliary chambers contained 20, 35, 50, and 70 per cent of the total clearance volume. Each chamber was connected to the cylinder by a single circular passage, flared at both ends, and of a cross-sectional area proportional to the chamber volume, thereby giving the same calculated air-flow velocity through each passage. Results of engine-performance tests are presented with variations of power, fuel consumption, explosion pressure, rate of pressure rise, ignition lag, heat loss to the cooling water, and motoring characteristics. For good performance the minimum auxiliary chamber volume, with the cylinder head design used, was 35 per cent of the total clearance volume; for larger volumes the performance improves but slightly. With the auxiliary chamber that contained 35 percent of the clearance volume there were obtained the lowest explosion pressures, medium rates of pressure rise, and slightly less than the maximum power. For all clearance distributions an increase in engine speed decreased the ignition lag in seconds and increased the rate of pressure rise.
Orbit Transfer Vehicle (OTV) engine, phase A study. Volume 2: Study
NASA Technical Reports Server (NTRS)
Mellish, J. A.
1979-01-01
The hydrogen oxygen engine used in the orbiter transfer vehicle is described. The engine design is analyzed and minimum engine performance and man rating requirements are discussed. Reliability and safety analysis test results are presented and payload, risk and cost, and engine installation parameters are defined. Engine tests were performed including performance analysis, structural analysis, thermal analysis, turbomachinery analysis, controls analysis, and cycle analysis.
NASA Technical Reports Server (NTRS)
Andrews, E. H., Jr.; Mackley, E. A.
1976-01-01
The NASA Hypersonic Research Engine Project was undertaken to design, develop, and construct a hypersonic research ramjet engine for high performance and to flight test the developed concept on the X-15-2A airplane over the speed range from Mach 3 to 8. Computer program results are presented here for the Mach 7 component integration and performance tests.
HINES, Lindsay J.; MILLER, Eric N.; HINKIN, Charles H.; ALGER, Jeffery R.; BARKER, Peter; GOODKIN, Karl; MARTIN, Eileen M.; MARUCA, Victoria; RAGIN, Ann; SACKTOR, Ned; SANDERS, Joanne; SELNES, Ola; BECKER, James T.
2015-01-01
Objective To characterize the relationship between dispersion-based intra-individual variability (IIVd) in neuropsychological test performance and brain volume among HIV seropositive and seronegative men and to determine the effects of cardiovascular risk and HIV infection on this relationship. Methods Magnetic Resonance Imaging (MRI) was used to acquire high-resolution neuroanatomic data from 147 men age 50 and over, including 80 HIV seropositive (HIV+) and 67 seronegative controls (HIV−) in this cross-sectional cohort study. Voxel Based Morphometry was used to derive volumetric measurements at the level of the individual voxel. These brain structure maps were analyzed using Statistical Parametric Mapping (SPM2). IIVd was measured by computing intra-individual standard deviations (ISD’s) from the standardized performance scores of five neuropsychological tests: Wechsler Memory Scale-III Visual Reproduction I and II, Logical Memory I and II, Wechsler Adult Intelligence Scale-III Letter Number Sequencing. Results Total gray matter (GM) volume was inversely associated with IIVd. Among all subjects, IIVd -related GM atrophy was observed primarily in: 1) the inferior frontal gyrus bilaterally, the left inferior temporal gyrus extending to the supramarginal gyrus, spanning the lateral sulcus; 2) the right superior parietal lobule and intraparietal sulcus; and, 3) dorsal/ventral regions of the posterior section of the transverse temporal gyrus. HIV status, biological, and cardiovascular disease (CVD) variables were not linked to IIVd -related GM atrophy. Conclusions IIVd in neuropsychological test performance may be a sensitive marker of cortical integrity in older adults, regardless of HIV infection status or CVD risk factors, and degree of intra-individual variability links with volume loss in specific cortical regions; independent of mean-level performance on neuropsychological tests. PMID:26303224
Early Cerebral Small Vessel Disease and Brain Volume, Cognition, and Gait
Smith, Eric E; O'Donnell, Martin; Dagenais, Gilles; Lear, Scott A; Wielgosz, Andreas; Sharma, Mukul; Poirier, Paul; Stotts, Grant; Black, Sandra E; Strother, Stephen; Noseworthy, Michael D; Benavente, Oscar; Modi, Jayesh; Goyal, Mayank; Batool, Saima; Sanchez, Karla; Hill, Vanessa; McCreary, Cheryl R; Frayne, Richard; Islam, Shofiqul; DeJesus, Jane; Rangarajan, Sumathy; Teo, Koon; Yusuf, Salim
2015-01-01
Objective Decline in cognitive function begins by the 40s, and may be related to future dementia risk. We used data from a community-representative study to determine whether there are age-related differences in simple cognitive and gait tests by the 40s, and whether these differences were associated with covert cerebrovascular disease on magnetic resonance imaging (MRI). Methods Between 2010 and 2012, 803 participants aged 40 to 75 years in the Prospective Urban Rural Epidemiological (PURE) study, recruited from prespecified postal code regions centered on 4 Canadian cities, underwent brain MRI and simple tests of cognition and gait as part of a substudy (PURE-MIND). Results Mean age was 58 ± 8 years. Linear decreases in performance on the Montreal Cognitive Assessment, Digit Symbol Substitution Test (DSST), and Timed Up and Go test of gait were seen with each age decade from the 40s to the 70s. Silent brain infarcts were observed in 3% of 40- to 49-year-olds, with increasing prevalence up to 18.9% in 70-year-olds. Silent brain infarcts were associated with slower timed gait and lower volume of supratentorial white matter. Higher volume of supratentorial MRI white matter hyperintensity was associated with slower timed gait and worse performance on DSST, and lower volumes of the supratentorial cortex and white matter, and cerebellum. Interpretation Covert cerebrovascular disease and its consequences on cognitive and gait performance and brain atrophy are manifest in some clinically asymptomatic persons as early as the 5th decade of life. Ann Neurol 2015;77:251–261 PMID:25428654
Comerci, M; Elefante, A; Strianese, D; Senese, R; Bonavolontà, P; Alfano, B; Bonavolontà, B; Brunetti, A
2013-08-01
This study was designed to validate a novel semi-automated segmentation method to measure regional intra-orbital fat tissue volume in Graves' ophthalmopathy. Twenty-four orbits from 12 patients with Graves' ophthalmopathy, 24 orbits from 12 controls, ten orbits from five MRI study simulations and two orbits from a digital model were used. Following manual region of interest definition of the orbital volumes performed by two operators with different levels of expertise, an automated procedure calculated intra-orbital fat tissue volumes (global and regional, with automated definition of four quadrants). In patients with Graves' disease, clinical activity score and degree of exophthalmos were measured and correlated with intra-orbital fat volumes. Operator performance was evaluated and statistical analysis of the measurements was performed. Accurate intra-orbital fat volume measurements were obtained with coefficients of variation below 5%. The mean operator difference in total fat volume measurements was 0.56%. Patients had significantly higher intra-orbital fat volumes than controls (p<0.001 using Student's t test). Fat volumes and clinical score were significantly correlated (p<0.001). The semi-automated method described here can provide accurate, reproducible intra-orbital fat measurements with low inter-operator variation and good correlation with clinical data.
DOT National Transportation Integrated Search
2012-10-01
The main objective of this study was to determine the effect on shrinkage, creep, : and abrasion resistance of high-volume fly ash (HVFA) concrete. The HVFA concrete : test program consisted of comparing the shrinkage, creep, and abrasion performance...
Recovery Act: Oxy-Combustion Techology Development for Industrial-Scale Boiler Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Levasseur, Armand
2014-04-30
Alstom Power Inc. (Alstom), under U.S. DOE/NETL Cooperative Agreement No. DE-NT0005290, is conducting a development program to generate detailed technical information needed for application of oxy-combustion technology. The program is designed to provide the necessary information and understanding for the next step of large-scale commercial demonstration of oxy combustion in tangentially fired boilers and to accelerate the commercialization of this technology. The main project objectives include: • Design and develop an innovative oxyfuel system for existing tangentially-fired boiler units that minimizes overall capital investment and operating costs. • Evaluate performance of oxyfuel tangentially fired boiler systems in pilot scale testsmore » at Alstom’s 15 MWth tangentially fired Boiler Simulation Facility (BSF). • Address technical gaps for the design of oxyfuel commercial utility boilers by focused testing and improvement of engineering and simulation tools. • Develop the design, performance and costs for a demonstration scale oxyfuel boiler and auxiliary systems. • Develop the design and costs for both industrial and utility commercial scale reference oxyfuel boilers and auxiliary systems that are optimized for overall plant performance and cost. • Define key design considerations and develop general guidelines for application of results to utility and different industrial applications. The project was initiated in October 2008 and the scope extended in 2010 under an ARRA award. The project completion date was April 30, 2014. Central to the project is 15 MWth testing in the BSF, which provided in-depth understanding of oxy-combustion under boiler conditions, detailed data for improvement of design tools, and key information for application to commercial scale oxy-fired boiler design. Eight comprehensive 15 MWth oxy-fired test campaigns were performed with different coals, providing detailed data on combustion, emissions, and thermal behavior over a matrix of fuels, oxyprocess variables and boiler design parameters. Significant improvement of CFD modeling tools and validation against 15 MWth experimental data has been completed. Oxy-boiler demonstration and large reference designs have been developed, supported with the information and knowledge gained from the 15 MWth testing. The results from the 15 MWth testing in the BSF and complimentary bench-scale testing are addressed in this volume (Volume II) of the final report. The results of the modeling efforts (Volume III) and the oxy boiler design efforts (Volume IV) are reported in separate volumes.« less
Reducing inpatient heritable thrombophilia testing using a clinical decision-making tool.
Smith, Tyler W; Pi, David; Hudoba, Monika; Lee, Agnes Y Y
2014-04-01
To evaluate the impact of a clinical decision-making tool, designed to educate physicians regarding heritable thrombophilia (HT) testing, on the volume of testing in hospitalised patients in the tertiary care setting. We performed a retrospective cohort study over a 6-year period (2007-2012) at a single tertiary care centre intervention site and two regional control sites. In January 2010, the intervention site instituted a policy change whereby physicians ordering HT testing on inpatients needed to complete a pre-preprinted order (PPO) form that outlined the limitations of HT testing in the hospitalised setting. Failure to complete the PPO within 24 h resulted in test cancellation. Our main outcome measure was the volume of HT testing performed at the three study sites. Introduction of the PPO resulted in a 79.4% (95% CI 71.2% to 87.6%) reduction in factor V Leiden (FVL) testing at the intervention site. This decrease was significantly greater compared with those in the two control teaching hospitals over the same time periods (33.7% and 43.6%; both p<0.001). Reductions in FVL testing postintervention were observed among all ordering specialists. Similar postintervention reductions in testing volumes were observed for antithrombin (57.4%), protein C (61.9%) and protein S (62.2%) activity assays. In a large tertiary care hospital, the introduction of a clinical decision-making tool significantly reduced HT testing in inpatients across clinical specialties. The impact on patient outcome should be assessed in further studies.
Bigger is better! Hippocampal volume and declarative memory performance in healthy young men.
Pohlack, Sebastian T; Meyer, Patric; Cacciaglia, Raffaele; Liebscher, Claudia; Ridder, Stephanie; Flor, Herta
2014-01-01
The importance of the hippocampus for declarative memory processes is firmly established. Nevertheless, the issue of a correlation between declarative memory performance and hippocampal volume in healthy subjects still remains controversial. The aim of the present study was to investigate this relationship in more detail. For this purpose, 50 healthy young male participants performed the California Verbal Learning Test. Hippocampal volume was assessed by manual segmentation of high-resolution 3D magnetic resonance images. We found a significant positive correlation between putatively hippocampus-dependent memory measures like short-delay retention, long-delay retention and discriminability and percent hippocampal volume. No significant correlation with measures related to executive processes was found. In addition, percent amygdala volume was not related to any of these measures. Our data advance previous findings reported in studies of brain-damaged individuals in a large and homogeneous young healthy sample and are important for theories on the neural basis of episodic memory.
Shimasaki, Noriko; Shinohara, Katsuaki; Morikawa, Hideki
2017-12-07
For occupational safety, healthcare workers must select and wear appropriate personal protective equipment (PPE), protective clothing, and masks as countermeasures against exposure to infectious body fluids and blood splash. It is important for healthcare workers to ensure the protective performance of each PPE against penetration of pathogens. The International Standards Organization (ISO) 22609 test evaluates the effectiveness of medical facemasks to protect against penetration of splashed synthetic blood. However, in this method, the protective performance is determined only visually, without quantification of leaked liquid volume. Therefore, in this study, we modified the ISO 22609 test method to quantify the volume of leaked liquid and obtain a more accurate assessment of the protection performance. We tested non-woven and woven materials used for masks or protective clothing, and the performance of each material was classified using this new method. We found that the quantity of leaked synthetic blood was dependent on the structural characteristics of each material. These findings will allow healthcare workers to select the most appropriate PPE for a given situation or task.
SHIMASAKI, Noriko; SHINOHARA, Katsuaki; MORIKAWA, Hideki
2017-01-01
For occupational safety, healthcare workers must select and wear appropriate personal protective equipment (PPE), protective clothing, and masks as countermeasures against exposure to infectious body fluids and blood splash. It is important for healthcare workers to ensure the protective performance of each PPE against penetration of pathogens. The International Standards Organization (ISO) 22609 test evaluates the effectiveness of medical facemasks to protect against penetration of splashed synthetic blood. However, in this method, the protective performance is determined only visually, without quantification of leaked liquid volume. Therefore, in this study, we modified the ISO 22609 test method to quantify the volume of leaked liquid and obtain a more accurate assessment of the protection performance. We tested non-woven and woven materials used for masks or protective clothing, and the performance of each material was classified using this new method. We found that the quantity of leaked synthetic blood was dependent on the structural characteristics of each material. These findings will allow healthcare workers to select the most appropriate PPE for a given situation or task. PMID:28978815
Senior Dance Experience, Cognitive Performance, and Brain Volume in Older Women.
Niemann, Claudia; Godde, Ben; Voelcker-Rehage, Claudia
2016-01-01
Physical activity is positively related to cognitive functioning and brain volume in older adults. Interestingly, different types of physical activity vary in their effects on cognition and on the brain. For example, dancing has become an interesting topic in aging research, as it is a popular leisure activity among older adults, involving cardiovascular and motor fitness dimensions that can be positively related to cognition. However, studies on brain structure are missing. In this study, we tested the association of long-term senior dance experience with cognitive performance and gray matter brain volume in older women aged 65 to 82 years. We compared nonprofessional senior dancers ( n = 28) with nonsedentary control group participants without any dancing experience ( n = 29), who were similar in age, education, IQ score, lifestyle and health factors, and fitness level. Differences neither in the four tested cognitive domains (executive control, perceptual speed, episodic memory, and long-term memory) nor in brain volume (VBM whole-brain analysis, region-of-interest analysis of the hippocampus) were observed. Results indicate that moderate dancing activity (1-2 times per week, on average) has no additional effects on gray matter volume and cognitive functioning when a certain lifestyle or physical activity and fitness level are reached.
Ruggieri, Serena; Petracca, Maria; Miller, Aaron; Krieger, Stephen; Ghassemi, Rezwan; Bencosme, Yadira; Riley, Claire; Howard, Jonathan; Lublin, Fred; Inglese, Matilde
2015-12-01
The investigation of cortical gray matter (GM), deep GM nuclei, and spinal cord damage in patients with primary progressive multiple sclerosis (PP-MS) provides insights into the neurodegenerative process responsible for clinical progression of MS. To investigate the association of magnetic resonance imaging measures of cortical, deep GM, and spinal cord damage and their effect on clinical disability. Cross-sectional analysis of 26 patients with PP-MS (mean age, 50.9 years; range, 31-65 years; including 14 women) and 20 healthy control participants (mean age, 51.1 years; range, 34-63 years; including 11 women) enrolled at a single US institution. Clinical disability was measured with the Expanded Disability Status Scale, 9-Hole Peg Test, and 25-Foot Walking Test. We collected data from January 1, 2012, through December 31, 2013. Data analysis was performed from January 21 to April 10, 2015. Cortical lesion burden, brain and deep GM volumes, spinal cord area and volume, and scores on the Expanded Disability Status Scale (score range, 0 to 10; higher scores indicate greater disability), 9-Hole Peg Test (measured in seconds; longer performance time indicates greater disability), and 25-Foot Walking Test (test covers 7.5 m; measured in seconds; longer performance time indicates greater disability). The 26 patients with PP-MS showed significantly smaller mean (SD) brain and spinal cord volumes than the 20 control group patients (normalized brain volume, 1377.81 [65.48] vs 1434.06 [53.67] cm3 [P = .003]; normalized white matter volume, 650.61 [46.38] vs 676.75 [37.02] cm3 [P = .045]; normalized gray matter volume, 727.20 [40.74] vs 757.31 [38.95] cm3 [P = .02]; normalized neocortical volume, 567.88 [85.55] vs 645.00 [42.84] cm3 [P = .001]; normalized spinal cord volume for C2-C5, 72.71 [7.89] vs 82.70 [7.83] mm3 [P < .001]; and normalized spinal cord volume for C2-C3, 64.86 [7.78] vs 72.26 [7.79] mm3 [P =.002]). The amount of damage in deep GM structures, especially with respect to the thalamus, was correlated with the number and volume of cortical lesions (mean [SD] thalamus volume, 8.89 [1.10] cm3; cortical lesion number, 12.6 [11.7]; cortical lesion volume, 0.65 [0.58] cm3; r = -0.52; P < .01). Thalamic atrophy also showed an association with cortical lesion count in the frontal cortex (mean [SD] thalamus volume, 8.89 [1.1] cm3; cortical lesion count in the frontal lobe, 5.0 [5.7]; r = -0.60; P < .01). No association was identified between magnetic resonance imaging measures of the brain and spinal cord damage. In this study, the neurodegenerative process occurring in PP-MS appeared to spread across connected structures in the brain while proceeding independently in the spinal cord. These results support the relevance of anatomical connectivity for the propagation of MS damage in the PP phenotype.
Pre-Launch Performance Testing of the ICESat-2/ATLAS Flight Science Receiver Algorithms
NASA Astrophysics Data System (ADS)
Mcgarry, J.; Carabajal, C. C.; Saba, J. L.; Rackley, A.; Holland, S.
2016-12-01
NASA's Advanced Topographic Laser Altimeter System (ATLAS) will be the single instrument on the ICESat-2 spacecraft which is expected to launch in late 2017 with a 3 year mission lifetime. The ICESat-2 planned orbital altitude is 500 km with a 92 degree inclination and 91-day repeat tracks. ATLAS is a single-photon detection system transmitting at 532nm with a laser repetition rate of 10 kHz and a 6 spot pattern on the Earth's surface. Without some method of reducing the received data, the volume of ATLAS telemetry would far exceed the normal X-band downlink capability. To reduce the data volume to an acceptable level a set of onboard Receiver Algorithms has been developed. These Algorithms limit the daily data volume by distinguishing surface echoes from the background noise and allowing the instrument to telemeter data from only a small vertical region about the signal. This is accomplished through the use of an onboard Digital Elevation Model (DEM), signal processing techniques, and onboard relief and surface reference maps. The ATLAS Receiver Algorithms have been completed and have been verified during Instrument testing in the spacecraft assembly area at the Goddard Space Flight Center in late 2015 and early 2016. Testing has been performed at ambient temperature with a pressure of one atmosphere as well as at the expected hot and cold temperatures in a vacuum. Results from testing to date show the Receiver Algorithms have the ability to handle a wide range of signal and noise levels with a very good sensitivity at relatively low signal to noise ratios. Testing with the ATLAS instrument and flight software shows very good agreement with previous Simulator testing and all of the requirements for ATLAS Receiver Algorithms were successfully verified during Run for the Record Testing in December 2015. This poster will describe the performance of the ATLAS Flight Science Receiver Algorithms during the Run for Record and Comprehensive Performance Testing performed at Goddard, which will give insight into the future on-orbit performance of the Algorithms. See the companion poster (Carabajal, et al) in this session.
Park, Jung-Jun; Yoo, Doo-Yeol; Park, Gi-Joon; Kim, Sung-Wook
2017-01-28
In this study, the flexural behavior of ultra-high-performance fiber-reinforced concrete (UHPFRC) is examined as a function of fiber length and volume fraction. Straight steel fiber with three different lengths ( l f ) of 13, 19.5, and 30 mm and four different volume fractions ( v f ) of 0.5%, 1.0%, 1.5%, and 2.0% are considered. Test results show that post-cracking flexural properties of UHPFRC, such as flexural strength, deflection capacity, toughness, and cracking behavior, improve with increasing fiber length and volume fraction, while first-cracking properties are not significantly influenced by fiber length and volume fraction. A 0.5 vol % reduction of steel fiber content relative to commercial UHPFRC can be achieved without deterioration of flexural performance by replacing short fibers ( l f of 13 mm) with longer fibers ( l f of 19.5 mm and 30 mm).
Park, Jung-Jun; Yoo, Doo-Yeol; Park, Gi-Joon; Kim, Sung-Wook
2017-01-01
In this study, the flexural behavior of ultra-high-performance fiber-reinforced concrete (UHPFRC) is examined as a function of fiber length and volume fraction. Straight steel fiber with three different lengths (lf) of 13, 19.5, and 30 mm and four different volume fractions (vf) of 0.5%, 1.0%, 1.5%, and 2.0% are considered. Test results show that post-cracking flexural properties of UHPFRC, such as flexural strength, deflection capacity, toughness, and cracking behavior, improve with increasing fiber length and volume fraction, while first-cracking properties are not significantly influenced by fiber length and volume fraction. A 0.5 vol % reduction of steel fiber content relative to commercial UHPFRC can be achieved without deterioration of flexural performance by replacing short fibers (lf of 13 mm) with longer fibers (lf of 19.5 mm and 30 mm). PMID:28772477
T-111 Rankine system corrosion test loop, volume 1
NASA Technical Reports Server (NTRS)
Harrison, R. W.; Hoffman, E. E.; Smith, J. P.
1975-01-01
Results are given of a program whose objective was to determine the performance of refractory metal alloys in a two loop Rankine test system. The test system consisted of a circulating lithium circuit heated to 1230 C maximum transferring heat to a boiling potassium circuit with a 1170 C superheated vapor temperature. The results demonstrate the suitability of the selected refractory alloys to perform from a chemical compatibility standpoint.
BDNF is Associated With Age-Related Decline in Hippocampal Volume
Erickson, Kirk I.; Prakash, Ruchika Shaurya; Voss, Michelle W.; Chaddock, Laura; Heo, Susie; McLaren, Molly; Pence, Brandt D.; Martin, Stephen A.; Vieira, Victoria J.; Woods, Jeffrey A.; Kramer, Arthur F.
2010-01-01
Hippocampal volume shrinks in late adulthood, but the neuromolecular factors that trigger hippocampal decay in aging humans remains a matter of speculation. In rodents, brain derived neurotrophic factor (BDNF) promotes the growth and proliferation of cells in the hippocampus and is important in long-term potentiation and memory formation. In humans, circulating levels of BDNF decline with advancing age and a genetic polymorphism for BDNF has been related to gray matter volume loss in old age. In this study, we tested whether age-related reductions in serum levels of BDNF would be related to shrinkage of the hippocampus and memory deficits in older adults. Hippocampal volume was acquired by automated segmentation of magnetic resonance images in 142 older adults without dementia. The caudate nucleus was also segmented and examined in relation to levels of serum BDNF. Spatial memory was tested using a paradigm in which memory load was parametrically increased. We found that increasing age was associated with smaller hippocampal volumes, reduced levels of serum BDNF, and poorer memory performance. Lower levels of BDNF were associated with smaller hippocampi and poorer memory, even when controlling for the variation related to age. In an exploratory mediation analysis, hippocampal volume mediated the age-related decline in spatial memory and BDNF mediated the age-related decline in hippocampal volume. Caudate nucleus volume was unrelated to BDNF levels or spatial memory performance. Our results identify serum BDNF as a significant factor related to hippocampal shrinkage and memory decline in late adulthood. PMID:20392958
Cassim, Naseem; Schnippel, Kathryn; Coetzee, Lindi Marie; Glencross, Deborah Kim
2017-01-01
Cryptococcal meningitis is a major cause of mortality and morbidity in countries with high HIV prevalence, primarily affecting patients whose CD4 are < = 100 cells/μl. Routine Cryptococcal Antigen (CrAg) screening is thus recommended in the South African HIV treatment guidelines for all patients with CD4 counts < = 100 cells/μl, followed by pre-emptive anti-fungal therapy where CrAg results are positive. A laboratory-based reflexed CrAg screening approach, using a Lateral Flow Assay (LFA) on remnant EDTA CD4 blood samples, was piloted at three CD4 laboratories. This study aimed to assess the cost-per-result of laboratory-based reflexed CrAg screening at one pilot CD4 referral laboratory. CD4 test volumes from 2014 were extracted to estimate percentage of CD4 < = 100 cells/μl. Daily average volumes were derived, assuming 12 months per/year and 21.73 working days per/month. Costing analyses were undertaken using Microsoft Excel and Stata with a provider prospective. The cost-per-result was estimated using a bottom-up method, inclusive of test kits and consumables (reagents), laboratory equipment and technical effort costs. The ZAR/$ exchange of 14.696/$1 was used, where applicable. One-way sensitivity analyses on the cost-per-result were conducted for possible error rates (3%- 8%, reductions or increases in reagent costs as well as test volumes (ranging from -60% to +60%). The pilot CD4 laboratory performed 267000 CD4 tests in 2014; ~ 9.3% (27500) reported CD4< = 100 cells/μl, equivalent to 106 CrAg tests performed daily. A batch of 30-tests could be performed in 1.6 hours, including preparation and analysis time. A cost-per-result of $4.28 was reported, with reagents contributing $3.11 (72.8%), while technical effort and laboratory equipment overheads contributed $1.17 (27.2%) and $0.03 (<1%) respectively. One-way sensitivity analyses including increasing or decreasing test volumes by 60% revealed a cost-per-result range of $3.84 to $6.03. A cost-per-result of $4.28 was established in a typical CD4 service laboratory to enable local budgetary cost projections and programmatic cost-effectiveness modelling. Varying reagent costs linked to currency exchange and varying test volumes in different levels of service can lead to varying cost-per-test and technical effort to manage workload, with an inverse relationship of higher costs expected at lower volumes of tests.
Schulz, Wolfgang; Weiss, Stefan C; Weber, Walter H; Winzenbacher, Rudi
2017-10-13
In effect-directed analysis (EDA) with high-performance thin-layer chromatography (HPTLC), the effect is often detected using images. Thus, an approach to create inhibition chromatograms from these images was developed using the example of the HPTLC- bioluminescence inhibition test. A comparison between the cuvette test and the HPTLC test shows that the test on the plate is significantly more sensitive. To describe the strength of the effect, the EC 50 value is determined from the dose-response relationship. However, the inhibiting compounds are generally unknown and thus their concentrations are also unknown. Therefore, instead of the concentration, the known application volumes are used. This enables the calculation of the application volume necessary to achieve 50% inhibition. Since the volume is inversely proportional to the concentration, the reciprocal value of the calculated volume is indicated and is referred to as the reciprocal iso-inhibition volume (RIV). Using this RIV-concept, it is now possible to compare inhibition bands within and between plates. The entire evaluation is described by the means of two samples from a contaminated site using the bioluminescence inhibition. Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Y; Fullerton, G; Goins, B
Purpose: In our previous study a preclinical multi-modality quality assurance (QA) phantom that contains five tumor-simulating test objects with 2, 4, 7, 10 and 14 mm diameters was developed for accurate tumor size measurement by researchers during cancer drug development and testing. This study analyzed the errors during tumor volume measurement from preclinical magnetic resonance (MR), micro-computed tomography (micro- CT) and ultrasound (US) images acquired in a rodent tumor model using the preclinical multi-modality QA phantom. Methods: Using preclinical 7-Tesla MR, US and micro-CT scanners, images were acquired of subcutaneous SCC4 tumor xenografts in nude rats (3–4 rats per group;more » 5 groups) along with the QA phantom using the same imaging protocols. After tumors were excised, in-air micro-CT imaging was performed to determine reference tumor volume. Volumes measured for the rat tumors and phantom test objects were calculated using formula V = (π/6)*a*b*c where a, b and c are the maximum diameters in three perpendicular dimensions determined by the three imaging modalities. Then linear regression analysis was performed to compare image-based tumor volumes with the reference tumor volume and known test object volume for the rats and the phantom respectively. Results: The slopes of regression lines for in-vivo tumor volumes measured by three imaging modalities were 1.021, 1.101 and 0.862 for MRI, micro-CT and US respectively. For phantom, the slopes were 0.9485, 0.9971 and 0.9734 for MRI, micro-CT and US respectively. Conclusion: For both animal and phantom studies, random and systematic errors were observed. Random errors were observer-dependent and systematic errors were mainly due to selected imaging protocols and/or measurement method. In the animal study, there were additional systematic errors attributed to ellipsoidal assumption for tumor shape. The systematic errors measured using the QA phantom need to be taken into account to reduce measurement errors during the animal study.« less
Hermassi, Souhail; Schwesig, René; Wollny, Rainer; Fieseler, Georg; van den Tillaar, Roland; Fernandez-Fernandez, Jaime; Shephard, Roy J; Chelly, Mohamed S
2017-06-21
This study assessed inter-relationships between shuttle and straight repeated-sprint ability tests and the relationship of each measure to anthropometric and explosive lower limb performance data in elite handball players. Twenty-two elite male handball players (18.9 ± 0.2 years; body mass: 83.3 ± 1.1 kg, height: 1.79 ± 2.30 m, body fat: 12.8 ± 0.2%) completed tests that included a lower limb force-velocity test of peak power (Wpeak), jumping ability (squat and counter-movement jumps; SJ, CMJ), 1 repetition maximum (1-RM) half back squat, average sprint velocity over 5 m (V-5 m), peak velocity between 25-30 m (Vmax), and Yo-Yo Intermittent Recovery Test level 1 (Yo-Yo IR1), and anthropometric determinations of cross-sectional areas and muscle volumes for leg and thigh muscles. Data were compared with performance on 2 repeated sprint tests; the straight test [6 × 30 m (RSA30)] and the intermittent test [6 x (2 x 15 m) shuttle sprints (RSA15)]. V-5 m; 1-RM; and thigh and leg muscle cross-sectional areas and volumes showed relevant relationships to the shuttle RSA test (r2≥0.5). The Yo-Yo IR1 explained the largest percentage of variance in RSA15 total time (60%), and V-5 m also explained 56% of the variance in RSA15 total time. RSA15% fatigue was only related to 1-RM (explained variance: 58%), and the RSA30 test showed no useful correlations with any of the investigated predictors. Multiple-regression analyses using all physical tests explained 91% of the variance in RSA15 total time (p<0.001). The volume of the leg muscles seems important to power production and repeated sprints over distances of 15 m or less. RSA15 is related to muscular power, maximal strength, speed and endurance performance; however, the straight repeated sprint ability test is not, and thus does not seem relevant for the testing of handball players.
Rienstra, Anne; Groot, Paul F C; Spaan, Pauline E J; Majoie, Charles B L M; Nederveen, Aart J; Walstra, Gerard J M; de Jonghe, Jos F M; van Gool, Willem A; Olabarriaga, Silvia D; Korkhov, Vladimir V; Schmand, Ben
2013-01-01
Patients with mild cognitive impairment (MCI) do not always convert to dementia. In such cases, abnormal neuropsychological test results may not validly reflect cognitive symptoms due to brain disease, and the usual brain-behavior relationships may be absent. This study examined symptom validity in a memory clinic sample and its effect on the associations between hippocampal volume and memory performance. Eleven of 170 consecutive patients (6.5%; 13% of patients younger than 65 years) referred to memory clinics showed noncredible performance on symptom validity tests (SVTs, viz. Word Memory Test and Test of Memory Malingering). They were compared to a demographically matched group (n = 57) selected from the remaining patients. Hippocampal volume, measured by an automated volumetric method (Freesurfer), was correlated with scores on six verbal memory tests. The median correlation was r = .49 in the matched group. However, the relation was absent (median r = -.11) in patients who failed SVTs. Memory clinic samples may include patients who show noncredible performance, which invalidates their MCI diagnosis. This underscores the importance of applying SVTs in evaluating patients with cognitive complaints that may signify a predementia stage, especially when these patients are relatively young.
Estimating cubic volume of small diameter tree-length logs from ponderosa and lodgepole pine.
Marlin E. Plank; James M. Cahill
1984-01-01
A sample of 351 ponderosa pine (Pinus ponderosa Dougl. ex Laws.) and 509 lodgepole pine (Pinus contorta Dougl. ex Loud.) logs were used to evaluate the performance of three commonly used formulas for estimating cubic volume. Smalian's formula, Bruce's formula, and Huber's formula were tested to determine which...
NASA Technical Reports Server (NTRS)
Eller, H. H.; Sugg, F. E.
1970-01-01
The methods and procedures used to perform nondestructive testing inspections of the Saturn S-2 liquid hydrogen and liquid oxygen tank weldments during fabrication and after proof testing are described to document special skills developed during the program. All post-test inspection requirements are outlined including radiographic inspections procedures.
Thermal Expert System (TEXSYS): Systems automony demonstration project, volume 1. Overview
NASA Technical Reports Server (NTRS)
Glass, B. J. (Editor)
1992-01-01
The Systems Autonomy Demonstration Project (SADP) produced a knowledge-based real-time control system for control and fault detection, isolation, and recovery (FDIR) of a prototype two-phase Space Station Freedom external active thermal control system (EATCS). The Thermal Expert System (TEXSYS) was demonstrated in recent tests to be capable of reliable fault anticipation and detection, as well as ordinary control of the thermal bus. Performance requirements were addressed by adopting a hierarchical symbolic control approach-layering model-based expert system software on a conventional, numerical data acquisition and control system. The model-based reasoning capabilities of TEXSYS were shown to be advantageous over typical rule-based expert systems, particularly for detection of unforeseen faults and sensor failures. Volume 1 gives a project overview and testing highlights. Volume 2 provides detail on the EATCS test bed, test operations, and online test results. Appendix A is a test archive, while Appendix B is a compendium of design and user manuals for the TEXSYS software.
[Blood volume for biochemistry determinations--laboratory needs and everyday practice].
Sztefko, Krystyna; Mamica, Katarzyna; Bugajska, Jolanta; Maziarz, Barbara; Tomasik, Przemysław
2014-01-01
Blood loss due to diagnostic phlebotomy jest a very serious problem, especially for newborn, infants and critically ill patients on intensive care units. Although single blood loss can be easily tolerated in adults, in small babies and in patients who are frequently monitored based on laboratory tests iatrogenic anaemia can occur. To evaluate the blood volume drawn for routine biochemistry tests in relation to patient age and the number of parameters requested. Blood volume drawn for routine biochemistry measurements from patients hospitalized in University Children's Hospital (N = 2980, children age from one day to 18 years) and in University Hospital (N = 859, adults, aged > 1.8 years) in Cracow has been analyzed. Blood volume was calculated based on regular tube diameter and blood heights in the tube. In case of microvettes the blood volume was 0.2 ml. Statistical analysis has been performed by using PRISM 5.0. The statistical significance was set at p < 0.05. The mean values of blood volume were 3.02 +/- 0.92 ml and 4.12 +/- 0.68 ml in children and adults, respectively. Analyzing blood volume drawn in children using both microvettes and regular tubes, significant correlation between blood volume and patient age (p < 0.001) as well the number of requested parameters (p < 0.001). The latest relationship was true only for up to five parameters. However, analyzing the blood volume drawn into only into regular tubes blood volume was not related to patients age and number of laboratory tests requested. The proportion of microvettes used for blood collection was highest for newborns and infants, and in all cases where only one to three laboratory tests were requested. 1. All educational programs for nurses and doctors should include the information about current laboratory automation and methods miniaturization; 2) The amount of blood volume needed by laboratory for the requested number of tests should always be taken into account when diagnostic phlebotomy is necessary.
Nelson, Todd G.; Zimmerman, Trent K.; Fernelius, Janette D.; Magleby, Spencer P.; Howell, Larry L.
2016-01-01
Packing soft-sheet materials of approximately zero bending stiffness using Soft Origami (origami patterns applied to soft-sheet materials) into cylindrical volumes and their deployment via mechanisms or internal pressure (inflation) is of interest in fields including automobile airbags, deployable heart stents, inflatable space habitats, and dirigible and parachute packing. This paper explores twofold patterns, the ‘flasher’ and the ‘inverted-cone fold’, for packing soft-sheet materials into cylindrical volumes. Two initial packing methods and mechanisms are examined for each of the flasher and inverted-cone fold patterns. An application to driver’s side automobile airbags is performed, and deployment tests are completed to compare the influence of packing method and origami pattern on deployment performance. Following deployment tests, two additional packing methods for the inverted-cone fold pattern are explored and applied to automobile airbags. It is shown that modifying the packing method (using different methods to impose the same base pattern on the soft-sheet material) can lead to different deployment performance. In total, two origami patterns and six packing methods are examined, and the benefits of using Soft Origami patterns and packing methods are discussed. Soft Origami is presented as a viable method for efficiently packing soft-sheet materials into cylindrical volumes. PMID:27703707
NASA Astrophysics Data System (ADS)
Bruton, Jared T.; Nelson, Todd G.; Zimmerman, Trent K.; Fernelius, Janette D.; Magleby, Spencer P.; Howell, Larry L.
2016-09-01
Packing soft-sheet materials of approximately zero bending stiffness using Soft Origami (origami patterns applied to soft-sheet materials) into cylindrical volumes and their deployment via mechanisms or internal pressure (inflation) is of interest in fields including automobile airbags, deployable heart stents, inflatable space habitats, and dirigible and parachute packing. This paper explores twofold patterns, the `flasher' and the `inverted-cone fold', for packing soft-sheet materials into cylindrical volumes. Two initial packing methods and mechanisms are examined for each of the flasher and inverted-cone fold patterns. An application to driver's side automobile airbags is performed, and deployment tests are completed to compare the influence of packing method and origami pattern on deployment performance. Following deployment tests, two additional packing methods for the inverted-cone fold pattern are explored and applied to automobile airbags. It is shown that modifying the packing method (using different methods to impose the same base pattern on the soft-sheet material) can lead to different deployment performance. In total, two origami patterns and six packing methods are examined, and the benefits of using Soft Origami patterns and packing methods are discussed. Soft Origami is presented as a viable method for efficiently packing soft-sheet materials into cylindrical volumes.
Bruton, Jared T; Nelson, Todd G; Zimmerman, Trent K; Fernelius, Janette D; Magleby, Spencer P; Howell, Larry L
2016-09-01
Packing soft-sheet materials of approximately zero bending stiffness using Soft Origami (origami patterns applied to soft-sheet materials) into cylindrical volumes and their deployment via mechanisms or internal pressure (inflation) is of interest in fields including automobile airbags, deployable heart stents, inflatable space habitats, and dirigible and parachute packing. This paper explores twofold patterns, the 'flasher' and the 'inverted-cone fold', for packing soft-sheet materials into cylindrical volumes. Two initial packing methods and mechanisms are examined for each of the flasher and inverted-cone fold patterns. An application to driver's side automobile airbags is performed, and deployment tests are completed to compare the influence of packing method and origami pattern on deployment performance. Following deployment tests, two additional packing methods for the inverted-cone fold pattern are explored and applied to automobile airbags. It is shown that modifying the packing method (using different methods to impose the same base pattern on the soft-sheet material) can lead to different deployment performance. In total, two origami patterns and six packing methods are examined, and the benefits of using Soft Origami patterns and packing methods are discussed. Soft Origami is presented as a viable method for efficiently packing soft-sheet materials into cylindrical volumes.
... the body in various directions. A non-iodine contrast agent, usually gadolinium, is injected at the time of the exam. This test is performed to evaluate intra-abdominal organs, such ... large volumes of oral contrast to evaluate the small intestine. This is a ...
NASA Technical Reports Server (NTRS)
Wisler, D. C.
1980-01-01
Rear stage blading designs that have lower losses in their endwall boundary layer regions were developed. Test data and performance results for rotor B, stator B, and stator C - blading designs that offer promise of reducing endwall losses relative to the baseline are given. A low speed research compressor was the principal investigative tool. The tests were conducted using four identical stages of blading so that the test data would be obtained in a true multistage environment.
Burt, Dean; Lamb, Kevin; Nicholas, Ceri; Twist, Craig
2015-07-01
This study examined whether lower-volume exercise-induced muscle damage (EIMD) performed 2 weeks before high-volume muscle-damaging exercise protects against its detrimental effect on running performance. Sixteen male participants were randomly assigned to a lower-volume (five sets of ten squats, n = 8) or high-volume (ten sets of ten squats, n = 8) EIMD group and completed baseline measurements for muscle soreness, knee extensor torque, creatine kinase (CK), a 5-min fixed-intensity running bout and a 3-km running time-trial. Measurements were repeated 24 and 48 h after EIMD, and the running time-trial after 48 h. Two weeks later, both groups repeated the baseline measurements, ten sets of ten squats and the same follow-up testing (Bout 2). Data analysis revealed increases in muscle soreness and CK and decreases in knee extensor torque 24-48 h after the initial bouts of EIMD. Increases in oxygen uptake [Formula: see text], minute ventilation [Formula: see text] and rating of perceived exertion were observed during fixed-intensity running 24-48 h after EIMD Bout 1. Likewise, time increased and speed and [Formula: see text] decreased during a 3-km running time-trial 48 h after EIMD. Symptoms of EIMD, responses during fixed-intensity and running time-trial were attenuated in the days after the repeated bout of high-volume EIMD performed 2 weeks after the initial bout. This study demonstrates that the protective effect of lower-volume EIMD on subsequent high-volume EIMD is transferable to endurance running. Furthermore, time-trial performance was found to be preserved after a repeated bout of EIMD.
NASA Astrophysics Data System (ADS)
Otake, Y.; Murphy, R. J.; Grupp, R. B.; Sato, Y.; Taylor, R. H.; Armand, M.
2015-03-01
A robust atlas-to-subject registration using a statistical deformation model (SDM) is presented. The SDM uses statistics of voxel-wise displacement learned from pre-computed deformation vectors of a training dataset. This allows an atlas instance to be directly translated into an intensity volume and compared with a patient's intensity volume. Rigid and nonrigid transformation parameters were simultaneously optimized via the Covariance Matrix Adaptation - Evolutionary Strategy (CMA-ES), with image similarity used as the objective function. The algorithm was tested on CT volumes of the pelvis from 55 female subjects. A performance comparison of the CMA-ES and Nelder-Mead downhill simplex optimization algorithms with the mutual information and normalized cross correlation similarity metrics was conducted. Simulation studies using synthetic subjects were performed, as well as leave-one-out cross validation studies. Both studies suggested that mutual information and CMA-ES achieved the best performance. The leave-one-out test demonstrated 4.13 mm error with respect to the true displacement field, and 26,102 function evaluations in 180 seconds, on average.
Simulated pressure denaturation thermodynamics of ubiquitin.
Ploetz, Elizabeth A; Smith, Paul E
2017-12-01
Simulations of protein thermodynamics are generally difficult to perform and provide limited information. It is desirable to increase the degree of detail provided by simulation and thereby the potential insight into the thermodynamic properties of proteins. In this study, we outline how to analyze simulation trajectories to decompose conformation-specific, parameter free, thermodynamically defined protein volumes into residue-based contributions. The total volumes are obtained using established methods from Fluctuation Solution Theory, while the volume decomposition is new and is performed using a simple proximity method. Native and fully extended ubiquitin are used as the test conformations. Changes in the protein volumes are then followed as a function of pressure, allowing for conformation-specific protein compressibility values to also be obtained. Residue volume and compressibility values indicate significant contributions to protein denaturation thermodynamics from nonpolar and coil residues, together with a general negative compressibility exhibited by acidic residues. Copyright © 2017 Elsevier B.V. All rights reserved.
40 CFR Table 1 to Subpart Cccc of... - Emission Limitations
Code of Federal Regulations, 2011 CFR
2011-07-01
... per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Performance test (Method 29 of appendix A of this part). Carbon monoxide 157 parts per million by dry volume 3-run average (1 hour minimum sample time per run) Performance test (Method 10, 10A, or 10B of appendix A of this...
40 CFR Table 1 to Subpart Cccc of... - Emission Limitations
Code of Federal Regulations, 2010 CFR
2010-07-01
... per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Performance test (Method 29 of appendix A of this part). Carbon monoxide 157 parts per million by dry volume 3-run average (1 hour minimum sample time per run) Performance test (Method 10, 10A, or 10B of appendix A of this...
40 CFR Table 2 to Subpart Dddd of... - Model Rule-Emission Limitations
Code of Federal Regulations, 2010 CFR
2010-07-01
... meter 3-run average (1 hour minimum sample time per run) Performance test (Method 29 of appendix A of this part) Carbon monoxide 157 parts per million by dry volume 3-run average (1 hour minimum sample time per run) Performance test (Method 10, 10A, or 10B, of appendix A of this part) Dioxins/furans...
Development of a multicomponent force and moment balance for water tunnel applications, volume 2
NASA Technical Reports Server (NTRS)
Suarez, Carlos J.; Malcolm, Gerald N.; Kramer, Brian R.; Smith, Brooke C.; Ayers, Bert F.
1994-01-01
The principal objective of this research effort was to develop a multicomponent strain gauge balance to measure forces and moments on models tested in flow visualization water tunnels. Static experiments (which are discussed in Volume 1 of this report) were conducted, and the results showed good agreement with wind tunnel data on similar configurations. Dynamic experiments, which are the main topic of this Volume, were also performed using the balance. Delta wing models and two F/A-18 models were utilized in a variety of dynamic tests. This investigation showed that, as expected, the values of the inertial tares are very small due to the low rotating rates required in a low-speed water tunnel and can, therefore, be ignored. Oscillations in pitch, yaw and roll showed hysteresis loops that compared favorably to data from dynamic wind tunnel experiments. Pitch-up and hold maneuvers revealed the long persistence, or time-lags, of some of the force components in response to the motion. Rotary-balance experiments were also successfully performed. The good results obtained in these dynamic experiments bring a whole new dimension to water tunnel testing and emphasize the importance of having the capability to perform simultaneous flow visualization and force/moment measurements during dynamic situations.
NASA Astrophysics Data System (ADS)
Milani, Marco; Germán Rubino, J.; Müller, Tobias M.; Quintal, Beatriz; Holliger, Klaus
2014-05-01
Fractures are present in most geological formations and they tend to dominate not only their mechanical but also, and in particular, their hydraulic properties. For these reasons, the detection and characterization of fractures are of great interest in several fields of Earth sciences. Seismic attenuation has been recognized as a key attribute for this purpose, as both laboratory and field experiments indicate that the presence of fractures typically produces significant energy dissipation and that this attribute tends to increase with increasing fracture density. This energy loss is generally considered to be primarily due to wave-induced pressure diffusion between the fractures and the embedding porous matrix. That is, due to the strong compressibility contrast between these two domains, the propagation of seismic waves can generate a strong fluid pressure gradient and associated pressure diffusion, which leads to fluid flow and in turn results in frictional energy dissipation. Numerical simulations based on Biot's poroelastic wave equations are computationally very expensive. Alternative approaches consist in performing numerical relaxation or creep tests on representative elementary volumes (REV) of the considered medium. These tests are typically based on Biot's consolidation equations. Assuming that the heterogeneous poroelastic medium can be replaced by an effective, homogeneous viscoelastic solid, these numerical creep and relaxation tests allow for computing the equivalent seismic P-wave attenuation and phase velocity. From a practical point of view, an REV is typically characterized by the smallest volume for which rock physical properties are statistically stationary and representative of the probed medium in its entirety. A more general definition in the context of wavefield attributes is to consider an REV as the smallest volume over which the P-wave attenuation and phase velocity dispersion are independent of the applied boundary conditions. That is, the corresponding results obtained from creep and relaxation tests must be equivalent. For most analyses of media characterized by patchy saturation or double-porosity-type structures these two definitions are equivalent. It is, however, not clear whether this equivalence remains true in the presence of strong material contrasts as those prevailing in fractured rocks. In this work, we explore this question for periodically fractured media. To this end, we build a medium composed of infinite replicas of a unit volume containing one fracture. This unit volume coincides with the smallest possible volume that is statistically representative of the whole. Then, we perform several creep and relaxation tests on samples composed of an increasing number of these unit volumes. We find that the wave field signatures determined from relaxation tests are independent from the number of unit volumes. Conversely, the P-wave attenuation and phase velocity characteristics inferred from creep tests are different and vary with the number of unit volumes considered. Quite interestingly, the creep test results converge with those of the relaxation tests as the number of unit volumes increases. These findings are expected to have direct implications for corresponding laboratory measurements as well as for our understanding of seismic wave propagation in fractured media.
NASA Technical Reports Server (NTRS)
Nelson, D. P.
1981-01-01
Tabulated aerodynamic data from coannular nozzle performance tests are given for test runs 26 through 37. The data include nozzle thrust coefficient parameters, nozzle discharge coefficients, and static pressure tap measurements.
An inventory of aeronautical ground research facilities. Volume 3: Structural
NASA Technical Reports Server (NTRS)
Pirrello, C. J.; Hardin, R. D.; Heckart, M. V.; Brown, K. R.
1971-01-01
An inventory of test facilities for conducting acceleration, environmental, impact, structural shock, load, heat, vibration, and noise tests is presented. The facility is identified with a description of the equipment, the testing capabilities, and cost of operation. Performance data for the facility are presented in charts and tables.
Neuroimaging correlates of parent ratings of working memory in typically developing children
Mahone, E. Mark; Martin, Rebecca; Kates, Wendy R.; Hay, Trisha; Horská, Alena
2009-01-01
The purpose of the present study was to investigate construct validity of parent ratings of working memory in children, using a multi-trait/multi-method design including neuroimaging, rating scales, and performance-based measures. Thirty-five typically developing children completed performance-based tests of working memory and nonexecutive function (EF) skills, received volumetric MRI, and were rated by parents on both EF-specific and broad behavior rating scales. After controlling for total cerebral volume and age, parent ratings of working memory were significantly correlated with frontal gray, but not temporal, parietal, or occipital gray, or any lobar white matter volumes. Performance-based measures of working memory were also moderately correlated with frontal lobe gray matter volume; however, non-EF parent ratings and non-EF performance-based measures were not correlated with frontal lobe volumes. Results provide preliminary support for the convergent and discriminant validity of parent ratings of working memory, and emphasize their utility in exploring brain–behavior relationships in children. Rating scales that directly examine EF skills may potentially have ecological validity, not only for “everyday” function, but also as correlates of brain volume. PMID:19128526
Changes in olfactory bulb volume following lateralized olfactory training.
Negoias, S; Pietsch, K; Hummel, T
2017-08-01
Repeated exposure to odors modifies olfactory function. Consequently, "olfactory training" plays a significant role in hyposmia treatment. In addition, numerous studies show that the olfactory bulb (OB) volume changes in disorders associated with olfactory dysfunction. Aim of this study was to investigate whether and how olfactory bulb volume changes in relation to lateralized olfactory training in healthy people. Over a period of 4 months, 97 healthy participants (63 females and 34 males, mean age: 23.74 ± 4.16 years, age range: 19-43 years) performed olfactory training by exposing the same nostril twice a day to 4 odors (lemon, rose, eucalyptus and cloves) while closing the other nostril. Before and after olfactory training, magnetic resonance imaging (MRI) scans were performed to measure OB volume. Furthermore, participants underwent lateralized odor threshold and odor identification testing using the "Sniffin' Sticks" test battery.OB volume increased significantly after olfactory training (11.3 % and 13.1 % respectively) for both trained and untrained nostril. No significant effects of sex, duration and frequency of training or age of the subjects were seen. Interestingly, PEA odor thresholds worsened after training, while olfactory identification remained unchanged.These data show for the first time in humans that olfactory training may involve top-down process, which ultimately lead to a bilateral increase in olfactory bulb volume.
Lalani, Sanam J; Duffield, Tyler C; Trontel, Haley G; Bigler, Erin D; Abildskov, Tracy J; Froehlich, Alyson; Prigge, Molly B D; Travers, Brittany G; Anderson, Jeffrey S; Zielinski, Brandon A; Alexander, Andrew; Lange, Nicholas; Lainhart, Janet E
2018-06-01
Studies have shown that individuals with autism spectrum disorder (ASD) tend to perform significantly below typically developing individuals on standardized measures of attention, even when controlling for IQ. The current study sought to examine within ASD whether anatomical correlates of attention performance differed between those with average to above-average IQ (AIQ group) and those with low-average to borderline ability (LIQ group) as well as in comparison to typically developing controls (TDC). Using automated volumetric analyses, we examined regional volume of classic attention areas including the superior frontal gyrus, anterior cingulate cortex, and precuneus in ASD AIQ (n = 38) and LIQ (n = 18) individuals along with 30 TDC. Auditory attention performance was assessed using subtests of the Test of Memory and Learning (TOMAL) compared among the groups and then correlated with regional brain volumes. Analyses revealed group differences in attention. The three groups did not differ significantly on any auditory attention-related brain volumes; however, trends toward significant size-attention function interactions were observed. Negative correlations were found between the volume of the precuneus and auditory attention performance for the AIQ ASD group, indicating larger volume related to poorer performance. Implications for general attention functioning and dysfunctional neural connectivity in ASD are discussed.
Evaluation of Geosynthetic-Reinforced Flexible Pavements using Static Plate Load Tests
DOT National Transportation Integrated Search
2010-01-01
This study focuses on the response of full-scale geogrid-reinforced flexible pavements to static surface loading. Specifically, static plate load (SPL) tests were performed on a low-volume, asphalt pavement frontage road in Eastern Arkansas, USA (the...
Evaluation of the intelligent cruise control system : volume 1 : study results
DOT National Transportation Integrated Search
1999-10-01
The Intelligent Cruise Control (ICC) system evaluation was based on an ICC Field Operational Test (FOT) performed in Michigan. The FOT involved 108 volunteers recruited to drive ten ICC-equipped Chrysler Concordes. Testing was initiated in July 1996 ...
PNEUMATIC PUMP TEST FOR DESIGN OF SOIL VACUUM EXTRACTION
In-situ pneumatic pumping tests were performed to estimate the pneumatic permeability at a site containing soils contaminated with aviation gasoline. Determination of pneumatic permeability was necessary to evaluate soil-air discharge or pore volume exchange rates. Pressure propa...
NASA Technical Reports Server (NTRS)
Andrews, E. H., Jr.; Mackley, E. A.
1976-01-01
Computer program performance results of a Mach 6 hypersonic research engine during supersonic and subsonic combustion modes were presented. The combustion mode transition was successfully performed, exit surveys made, and effects of altitude, angle of attack, and inlet spike position were determined during these tests.
NASA Astrophysics Data System (ADS)
Kohnová, Silvia; Papaioannou, George; Bacigál, Tomáš; Szolgay, Ján; Hlavčová, Kamila; Loukas, Athanasios; Výleta, Roman
2017-04-01
Flood frequency analysis is often performed as a univariate analysis of flood peaks using a suitable theoretical probability distribution of the annual maximum flood peaks or peak over threshold values. However, also other flood attributes, such as flood volume and duration, are often necessary for the design of hydrotechnical structures and projects. In this study, the suitability of various copula families for a bivariate analysis of peak discharges and flood volumes has been tested on the streamflow data from gauging stations along the whole Danube River. Kendall's rank correlation coefficient (tau) quantifies the dependence between flood peak discharge and flood volume settings. The methodology is tested on two different data samples: 1) annual maximum flood (AMF) peaks with corresponding flood volumes, which is a typical choice for engineering studies and 2). annual maximum flood (AMF) peaks combined with annual maximum flow volumes of fixed durations at 5, 10, 15, 20, 25, 30 and 60 days, which can be regarded as a regime analysis of the dependence between the extremes of both variables in a given year. The bivariate modelling of the peak discharge - flood volume couples is achieved with the use of the the following copulas: Ali-Mikhail-Haq (AMH), Clayton, Frank, Joe, Gumbel, HuslerReiss, Galambos, Tawn, Normal, Plackett and FGM, respectively. Scatterplots of the observed and simulated peak discharge - flood volume pairs and goodness-of-fit tests have been used to assess the overall applicability of the copulas as well as observing any changes in suitable models along the Danube River. The results indicate that, almost all of the considered Archimedean class copulas (e.g. Frank, Clayton and Ali-Mikhail-Haq) perform better than the other copula families selected for this study, and that for the second data samples mostly the upper-tail-flat copulas were suitable.
40 CFR 798.4350 - Inhalation developmental toxicity study.
Code of Federal Regulations, 2011 CFR
2011-07-01
... particles of the test substance. It is used to compare particles of different sizes, shapes, and densities... substance given daily per unit volume of air. (c) Principle of the test method. The test substance is...) The temperature at which the test is performed should be maintained at 22 °C (±2°) for rodents or 20...
40 CFR 798.4350 - Inhalation developmental toxicity study.
Code of Federal Regulations, 2010 CFR
2010-07-01
... of the test substance. It is used to compare particles of different sizes, shapes, and densities and... substance given daily per unit volume of air. (c) Principle of the test method. The test substance is...) The temperature at which the test is performed should be maintained at 22 °C (±2°) for rodents or 20...
Dadvand, Payam; Pujol, Jesus; Macià, Dídac; Martínez-Vilavella, Gerard; Blanco-Hinojo, Laura; Mortamais, Marion; Alvarez-Pedrerol, Mar; Fenoll, Raquel; Esnaola, Mikel; Dalmau-Bueno, Albert; López-Vicente, Mónica; Basagaña, Xavier; Jerrett, Michael; Nieuwenhuijsen, Mark J; Sunyer, Jordi
2018-02-23
Proponents of the biophilia hypothesis believe that contact with nature, including green spaces, has a crucial role in brain development in children. Currently, however, we are not aware of evidence linking such exposure with potential effects on brain structure. We determined whether lifelong exposure to residential surrounding greenness is associated with regional differences in brain volume based on 3-dimensional magnetic resonance imaging (3D MRI) among children attending primary school. We performed a series of analyses using data from a subcohort of 253 Barcelona schoolchildren from the Brain Development and Air Pollution Ultrafine Particles in School Children (BREATHE) project. We averaged satellite-based normalized difference vegetation index (NDVI) across 100-m buffers around all residential addresses since birth to estimate each participant's lifelong exposure to residential surrounding greenness, and we used high-resolution 3D MRIs of brain anatomy to identify regional differences in voxel-wise brain volume associated with greenness exposure. In addition, we performed a supporting substudy to identify regional differences in brain volume associated with measures of working memory ( d' from computerized n -back tests) and inattentiveness (hit reaction time standard error from the Attentional Network Task instrument) that were repeated four times over one year. We also performed a second supporting substudy to determine whether peak voxel tissue volumes in brain regions associated with residential greenness predicted cognitive function test scores. Lifelong exposure to greenness was positively associated with gray matter volume in the left and right prefrontal cortex and in the left premotor cortex and with white matter volume in the right prefrontal region, in the left premotor region, and in both cerebellar hemispheres. Some of these regions partly overlapped with regions associated with cognitive test scores (prefrontal cortex and cerebellar and premotor white matter), and peak volumes in these regions predicted better working memory and reduced inattentiveness. Our findings from a study population of urban schoolchildren in Barcelona require confirmation, but they suggest that being raised in greener neighborhoods may have beneficial effects on brain development and cognitive function. https://doi.org/10.1289/EHP1876.
Thermal Expert System (TEXSYS): Systems autonomy demonstration project, volume 2. Results
NASA Technical Reports Server (NTRS)
Glass, B. J. (Editor)
1992-01-01
The Systems Autonomy Demonstration Project (SADP) produced a knowledge-based real-time control system for control and fault detection, isolation, and recovery (FDIR) of a prototype two-phase Space Station Freedom external active thermal control system (EATCS). The Thermal Expert System (TEXSYS) was demonstrated in recent tests to be capable of reliable fault anticipation and detection, as well as ordinary control of the thermal bus. Performance requirements were addressed by adopting a hierarchical symbolic control approach-layering model-based expert system software on a conventional, numerical data acquisition and control system. The model-based reasoning capabilities of TEXSYS were shown to be advantageous over typical rule-based expert systems, particularly for detection of unforeseen faults and sensor failures. Volume 1 gives a project overview and testing highlights. Volume 2 provides detail on the EATCS testbed, test operations, and online test results. Appendix A is a test archive, while Appendix B is a compendium of design and user manuals for the TEXSYS software.
Thermal Expert System (TEXSYS): Systems autonomy demonstration project, volume 2. Results
NASA Astrophysics Data System (ADS)
Glass, B. J.
1992-10-01
The Systems Autonomy Demonstration Project (SADP) produced a knowledge-based real-time control system for control and fault detection, isolation, and recovery (FDIR) of a prototype two-phase Space Station Freedom external active thermal control system (EATCS). The Thermal Expert System (TEXSYS) was demonstrated in recent tests to be capable of reliable fault anticipation and detection, as well as ordinary control of the thermal bus. Performance requirements were addressed by adopting a hierarchical symbolic control approach-layering model-based expert system software on a conventional, numerical data acquisition and control system. The model-based reasoning capabilities of TEXSYS were shown to be advantageous over typical rule-based expert systems, particularly for detection of unforeseen faults and sensor failures. Volume 1 gives a project overview and testing highlights. Volume 2 provides detail on the EATCS testbed, test operations, and online test results. Appendix A is a test archive, while Appendix B is a compendium of design and user manuals for the TEXSYS software.
Senior Dance Experience, Cognitive Performance, and Brain Volume in Older Women
Niemann, Claudia; Godde, Ben
2016-01-01
Physical activity is positively related to cognitive functioning and brain volume in older adults. Interestingly, different types of physical activity vary in their effects on cognition and on the brain. For example, dancing has become an interesting topic in aging research, as it is a popular leisure activity among older adults, involving cardiovascular and motor fitness dimensions that can be positively related to cognition. However, studies on brain structure are missing. In this study, we tested the association of long-term senior dance experience with cognitive performance and gray matter brain volume in older women aged 65 to 82 years. We compared nonprofessional senior dancers (n = 28) with nonsedentary control group participants without any dancing experience (n = 29), who were similar in age, education, IQ score, lifestyle and health factors, and fitness level. Differences neither in the four tested cognitive domains (executive control, perceptual speed, episodic memory, and long-term memory) nor in brain volume (VBM whole-brain analysis, region-of-interest analysis of the hippocampus) were observed. Results indicate that moderate dancing activity (1-2 times per week, on average) has no additional effects on gray matter volume and cognitive functioning when a certain lifestyle or physical activity and fitness level are reached. PMID:27738528
Space shuttle I-tube radiator testing at Johnson Space Center, May 1976, volume 1
NASA Technical Reports Server (NTRS)
Scheps, P. B.
1976-01-01
During the two weeks of thermal vacuum testing a representative forward panel was successfully operated in a variety of simulated environmental conditions. Performance limits for both high and low load operations were established. Confidence in the stable operation of the panel throughout its typical operating range was verified by the testing, and design studies were conducted to analyze the effects of the payload bay door, and the panel deployment angle, on performance.
Rhein, Cosima; Mühle, Christiane; Richter-Schmidinger, Tanja; Alexopoulos, Panagiotis; Doerfler, Arnd; Kornhuber, Johannes
2014-01-01
In neuropsychiatric diseases with basal ganglia involvement, higher cognitive functions are often impaired. In this exploratory study, we examined healthy young adults to gain detailed insight into the relationship between basal ganglia volume and cognitive abilities under non-pathological conditions. We investigated 137 healthy adults that were between the ages of 21 and 35 years with similar educational backgrounds. Magnetic resonance imaging (MRI) was performed, and volumes of basal ganglia nuclei in both hemispheres were calculated using FreeSurfer software. The cognitive assessment consisted of verbal, numeric and figural aspects of intelligence for either the fluid or the crystallised intelligence factor using the intelligence test Intelligenz-Struktur-Test (I-S-T 2000 R). Our data revealed significant correlations of the caudate nucleus and pallidum volumes with figural and numeric aspects of intelligence, but not with verbal intelligence. Interestingly, figural intelligence associations were dependent on sex and intelligence factor; in females, the pallidum volumes were correlated with crystallised figural intelligence (r = 0.372, p = 0.01), whereas in males, the caudate volumes were correlated with fluid figural intelligence (r = 0.507, p = 0.01). Numeric intelligence was correlated with right-lateralised caudate nucleus volumes for both females and males, but only for crystallised intelligence (r = 0.306, p = 0.04 and r = 0.459, p = 0.04, respectively). The associations were not mediated by prefrontal cortical subfield volumes when controlling with partial correlation analyses. The findings of our exploratory analysis indicate that figural and numeric intelligence aspects, but not verbal aspects, are strongly associated with basal ganglia volumes. Unlike numeric intelligence, the type of figural intelligence appears to be related to distinct basal ganglia nuclei in a sex-specific manner. Subcortical brain structures thus may contribute substantially to cognitive performance.
Chaim, Tiffany M; Schaufelberger, Maristela S; Ferreira, Luiz K; Duran, Fábio L S; Ayres, Adriana M; Scazufca, Marcia; Menezes, Paulo R; Amaro, Edson; Leite, Claudia C; Murray, Robin M; McGuire, Philip K; Rushe, Teresa M; Busatto, Geraldo F
2010-10-30
The present study aimed to investigate the presence of corpus callosum (CC) volume deficits in a population-based recent-onset psychosis (ROP) sample, and whether CC volume relates to interhemispheric communication deficits. For this purpose, we used voxel-based morphometry comparisons of magnetic resonance imaging data between ROP (n =122) and healthy control (n = 94) subjects. Subgroups (38 ROP and 39 controls) were investigated for correlations between CC volumes and performance on the Crossed Finger Localization Test (CFLT). Significant CC volume reductions in ROP subjects versus controls emerged after excluding substance misuse and non-right-handedness. CC reductions retained significance in the schizophrenia subgroup but not in affective psychoses subjects. There were significant positive correlations between CC volumes and CFLT scores in ROP subjects, specifically in subtasks involving interhemispheric communication. From these results, we can conclude that CC volume reductions are present in association with ROP. The relationship between such deficits and CFLT performance suggests that interhemispheric communication impairments are directly linked to CC abnormalities in ROP. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Electrical Characterization of the RCA CDP1822SD Random Access Memory, Volume 1, Appendix a
NASA Technical Reports Server (NTRS)
Klute, A.
1979-01-01
Electrical characteristization tests were performed on 35 RCA CDP1822SD, 256-by-4-bit, CMOS, random access memories. The tests included three functional tests, AC and DC parametric tests, a series of schmoo plots, rise/fall time screening, and a data retention test. All tests were performed on an automated IC test system with temperatures controlled by a thermal airstream unit. All the functional tests, the data retention test, and the AC and DC parametric tests were performed at ambient temperatures of 25 C, -20 C, -55 C, 85 C, and 125 C. The schmoo plots were performed at ambient temperatures of 25 C, -55 C, and 125 C. The data retention test was performed at 25 C. Five devices failed one or more functional tests and four of these devices failed to meet the expected limits of a number of AC parametric tests. Some of the schmoo plots indicated a small degree of interaction between parameters.
NASA Astrophysics Data System (ADS)
1981-09-01
Engineering design details for the principal systems, system operating modes, site facilities, and structures of an engineering test facility (ETF) of a 200 MWE power plant are presented. The ETF resembles a coal-fired steam power plant in many ways. It is analogous to a conventional plant which has had the coal combustor replaced with the MHD power train. Most of the ETF components are conventional. They can, however, be sized or configured differently or perform additional functions from those in a conventional coal power plant. The boiler not only generates steam, but also performs the functions of heating the MHD oxidant, recovering seed, and controlling emissions.
NASA Technical Reports Server (NTRS)
1981-01-01
Engineering design details for the principal systems, system operating modes, site facilities, and structures of an engineering test facility (ETF) of a 200 MWE power plant are presented. The ETF resembles a coal-fired steam power plant in many ways. It is analogous to a conventional plant which has had the coal combustor replaced with the MHD power train. Most of the ETF components are conventional. They can, however, be sized or configured differently or perform additional functions from those in a conventional coal power plant. The boiler not only generates steam, but also performs the functions of heating the MHD oxidant, recovering seed, and controlling emissions.
McMaster, Philip R. B.; Robertson, E. Arthur; Witebsky, Frank G.; MacLowry, James D.
1978-01-01
The MIC-2000 96-channel dispenser was evaluated for accuracy and repeatability of dispensing 50-μl volumes of water. It was found to perform within the manufacturer's specifications for accuracy of ±5%, but not within the limits for repeatability of ±1%. Overall, instrument performance was found to be satisfactory for the antimicrobial susceptibility testing technique which has been implemented in this laboratory. A method is suggested for simple evaluation of the volumes dispensed. A variety of antibiotics may be stored in Trypticase soy broth in Microtiter plates without loss of potency for periods of at least 2 weeks at −20°C and 4 months at −70°C. PMID:666304
Tomaiuolo, Francesco; Bivona, Umberto; Lerch, Jason P; Di Paola, Margherita; Carlesimo, Giovanni A; Ciurli, Paola; Matteis, Mariella; Cecchetti, Luca; Forcina, Antonio; Silvestro, Daniela; Azicnuda, Eva; Sabatini, Umberto; Di Giacomo, Dina; Caltagirone, Carlo; Petrides, Michael; Formisano, Rita
2012-03-10
In previous studies, we investigated a group of subjects who had suffered from a severe non missile traumatic brain injury (nmTBI) without macroscopic focal lesions and we found brain atrophy involving the hippocampus, fornix, corpus callosum, optic chiasm, and optic radiations. Memory test scores correlated mainly with fornix volumes [37,38]. In the present study, we re-examined 11 of these nmTBI subjects approximately 8 yr later. High-spatial resolution T1 weighted magnetic resonance images of the brain (1mm(3)) and standardised memory tests were performed once more in order to compare brain morphology and memory performance originally assessed 3-13 months after head injury (first study) and after 8-10 yr (present study). An overall improvement of memory test performance was demonstrated in the latest assessment, indicating that cognitive recovery in severe nmTBI subjects had not been completed within 3-13 months post-injury. It is notable that the volumes of the fornix and the hippocampus were reduced significantly from normal controls, but these volumes do not differ appreciatively between nmTBI subjects at first (after ∼1 yr) and at second (after ∼8 yr) scans. On the contrary, a clear reduction in the volume of the corpus callosus can be observed after ∼1 yr and a further significant reduction is evident after ∼8 yr, indicating that the neural degeneration in severe nmTBI continues long after the head trauma and relates to specific structures and not to the overall brain. Copyright © 2012 Elsevier Inc. All rights reserved.
Forum For Reading: The Journal for College Reading Teachers. Volume 9, No. 1.
ERIC Educational Resources Information Center
Pinette, Clayton, Ed.; Smith, Kent, Ed.
Five articles concerning college reading instruction are included in this special interest journal. Bill Fowler and Barry M. Kroll investigate hidden factors in tests of reading comprehension, revealing that most conventional tests have question-design weaknesses allowing students to perform successfully by the use of test wisdom alone. Imogene…
Santangelo, Gabriella; Bisecco, Alvino; Trojano, Luigi; Sacco, Rosaria; Siciliano, Mattia; d'Ambrosio, Alessandro; Della Corte, Marida; Lavorgna, Luigi; Bonavita, Simona; Tedeschi, Gioacchino; Gallo, Antonio
2018-05-26
Cognitive reserve (CR) is a construct that originates from the observation of poor correspondence between brain damage and clinical symptoms. The aim of the study was to investigate the association between cognitive reserve (CR), brain reserve (BR) and cognitive functions and to evaluate whether CR might attenuate/moderate the negative impact of brain atrophy and lesion load on cognitive functions in multiple sclerosis (MS). To achieve these aims, ninety-eight relapsing-remitting MS patients underwent the brief repeatable battery of neuropsychological tests and Stroop test (ST). CR was assessed by vocabulary-based estimate of lifetime intellectual enrichment. All patients underwent a 3T MRI to assess T2-lesion load and atrophy measures, including normalized gray matter and white matter (nWMV) volumes. The BR was evaluated by maximal lifetime brain volume expressed by intracranial volume (ICV). Hierarchical regressions were used to investigate whether higher BR and/or CR is related to better cognitive performances after controlling for potentially confounding factors. The ICV was not associated with any cognitive tests. Intellectual enrichment was positively associated with performance on tests assessing memory, attention and information processing speed, verbal fluency and inhibitory control. Significant relationship between nWMV and ST was moderated by intellectual enrichment. In conclusion, the findings suggested that CR seems to mitigate cognitive dysfunction in MS patients and can reduce the negative impact of brain atrophy on inhibitory control, relevant for integrity of instrumental activities of daily living.
DOE Office of Scientific and Technical Information (OSTI.GOV)
N. R. Mann; T. A. Todd; K. N. Brewer
1999-04-01
Development of waste treatment processes for the remediation of radioactive wastes is currently underway. A number of experiments were performed at the Idaho Nuclear Technology and Environmental Center (INTEC) located at the Idaho National Engineering and Environmental Laboratory (INEEL) with the commercially available sorbent material, IONSIV IE-911, crystalline silicotitanate (CST), manufactured by UOP LLC. The purpose of this work was to evaluate the removal efficiency, sorbent capacity and selectivity of CST for removing Cs-137 from actual and simulated acidic tank waste in addition to dissolved pilot-plant calcine solutions. The scope of this work included batch contact tests performed with non-radioactivemore » dissolved Al and Run-64 pilot plant calcines in addition to simulants representing the average composition of tank waste. Small-scale column tests were performed with actual INEEL tank WM-183 waste, tank waste simulant, dissolved Al and Run-64 pilot plant calcine solutions. Small-scale column experiments using actual WM-183 tank waste resulted in fifty-percent Cs-137 breakthrough at approximately 589 bed volumes. Small-scale column experiments using the tank waste simulant displayed fifty-percent Cs-137 breakthrough at approximately 700 bed volumes. Small-scale column experiments using dissolved Al calcine simulant displayed fifty-percent Cs-137 breakthrough at approximately 795 bed volumes. Column experiments with dissolved Run-64, pilot plant calcine did not reach fifty-percent breakthrough throughout the test.« less
JANNAF 30th Propellant Development and Characterization Subcommittee Meeting. Volume I
NASA Technical Reports Server (NTRS)
Moore, T. L. (Editor); Becker, D. L. (Editor)
2002-01-01
This volume, the first of three volumes, is a compilation of 22 unclassified/unlimited technical papers presented at the Joint Army-Navy-NASA-Air Force (JANNAF) 30th Propellant Development & Characterization Subcommittee Meeting, held on 18-21 March 2002 at the Sheraton Colorado Springs Hotel, Colorado Springs, Colorado. The papers presented herein reflect work performed in the areas of green energetic materials (GEM) development; liquid and gel propellant development; propellant surveillance and aging; and propellant chemistry test methods.
A simple bedside test to assess the swallowing dysfunction in Parkinson's disease.
Kanna, S Vinoth; Bhanu, K
2014-01-01
Swallowing changes are common in Parkinson's disease (PD). Early identification is essential to avoid complications of aspiration. To evaluate the swallowing ability of the PD patients and to correlate it with the indicators of disease progression. A total of 100 PD patients (70 males and 30 females) aged between 50 years and 70 years with varying stage, duration, and severity were enrolled in a cross-sectional study carried out between January and May 2012. A simple bedside water swallowing test was performed using standard 150 ml of water. Swallowing process was assessed under three categories-swallowing speeds (ml/s), swallowing volume (ml/swallow) and swallowing duration (s/swallow). Equal number of age and sex matched controls were also evaluated. All of them completed the task of swallowing. A mean swallowing speed (27.48 ml/s), swallowing volume (28.5 ml/s), and swallowing duration (1.05 s/swallow) was established by the control group. The PD patients showed decreased swallowing speed (7.15 ml/s in males and 6.61 ml/s in females), decreased swallowing volume (14.59 ml/swallow and 14 ml/swallow in females), and increased swallowing duration (2.37 s/swallow and 2.42 s/swallow) which are statistically significant. There was a significant positive correlation between the severity, duration, and staging of the disease with the swallowing performance and a poor correlation between the subjective reports of dysphagia and the objective performance on water swallow test. The water swallowing test is a simple bedside test to identify the swallowing changes early in PD. It is recommended to do the test in all PD Patients to detect dysphagia early and to intervene appropriately.
A simple bedside test to assess the swallowing dysfunction in Parkinson's disease
Kanna, S. Vinoth; Bhanu, K.
2014-01-01
Background: Swallowing changes are common in Parkinson's disease (PD). Early identification is essential to avoid complications of aspiration. Objectives: To evaluate the swallowing ability of the PD patients and to correlate it with the indicators of disease progression. Materials and Methods: A total of 100 PD patients (70 males and 30 females) aged between 50 years and 70 years with varying stage, duration, and severity were enrolled in a cross-sectional study carried out between January and May 2012. A simple bedside water swallowing test was performed using standard 150 ml of water. Swallowing process was assessed under three categories-swallowing speeds (ml/s), swallowing volume (ml/swallow) and swallowing duration (s/swallow). Equal number of age and sex matched controls were also evaluated. Results: All of them completed the task of swallowing. A mean swallowing speed (27.48 ml/s), swallowing volume (28.5 ml/s), and swallowing duration (1.05 s/swallow) was established by the control group. The PD patients showed decreased swallowing speed (7.15 ml/s in males and 6.61 ml/s in females), decreased swallowing volume (14.59 ml/swallow and 14 ml/swallow in females), and increased swallowing duration (2.37 s/swallow and 2.42 s/swallow) which are statistically significant. There was a significant positive correlation between the severity, duration, and staging of the disease with the swallowing performance and a poor correlation between the subjective reports of dysphagia and the objective performance on water swallow test. Conclusion: The water swallowing test is a simple bedside test to identify the swallowing changes early in PD. It is recommended to do the test in all PD Patients to detect dysphagia early and to intervene appropriately. PMID:24753662
Safari, Anahid; Fazeli, Mehdi; Namavar, Mohammad Reza; Tanideh, Nader; Jafari, Peyman; Borhani-Haghighi, Afshin
2017-01-01
Dimethyl fumarate (DMF) has immune-modulatory and neuro-protective characteristics that can be used for treatment of acute ischemic stroke. To investigate the therapeutic effects of DMF on histological and functional recovery of rats after transient middle cerebral artery (MCA) occlusion. 22 Sprague-Dawley male rats weighing 275-300 g were randomized into three groups by block randomization. In the sham group (n = 7), the neck was opened, but neither MCA was occluded, nor any drug was administered.The control group (n = 7) was treated with vehicle (methocel) by gavage for 14 days after MCA occlusion. In the DMF-treated group (n = 8), treatment was performed with 15 mg/kg body weight dimethyl fumarate twice a day for 14 days after MCA occlusion. Transient occlusion of the right MCA was performed by intraluminal thread method in the DMF-treated and the control group. Neurological deficit score (NDS), pole test, and adhesive removal test were performed before the surgery, and on post-operative Days 0, 3, 5, 7, 10, and 14. After the final behaviour test, the animals' brains were perfused and removed. Brains were frozen and sectioned serially and coronally using a cryostat. Infract volume and brain volume were estimated by stereology. The percentage of infarct volume was significantly lower in DMF-treated animals (5.76%) than in the control group (22.39%) (P < 0.0001). Regarding behavioural tests, the DMF-treated group showed better function in NDS on Days 7 (P = 0.041) and 10 (P = 0.046), but not in pole and adhesive removal tests. There was no significant correlation between behavioural tests and histological results. Dimethyl fumarate could be beneficial as a potential neuroprotective agent in the treatment of stroke.
Cotter, Christopher; Turcotte, Julie Catherine; Crawford, Bruce; Sharp, Gregory; Mah'D, Mufeed
2015-01-01
This work aims at three goals: first, to define a set of statistical parameters and plan structures for a 3D pretreatment thoracic and prostate intensity‐modulated radiation therapy (IMRT) quality assurance (QA) protocol; secondly, to test if the 3D QA protocol is able to detect certain clinical errors; and third, to compare the 3D QA method with QA performed with single ion chamber and 2D gamma test in detecting those errors. The 3D QA protocol measurements were performed on 13 prostate and 25 thoracic IMRT patients using IBA's COMPASS system. For each treatment planning structure included in the protocol, the following statistical parameters were evaluated: average absolute dose difference (AADD), percent structure volume with absolute dose difference greater than 6% (ADD6), and 3D gamma test. To test the 3D QA protocol error sensitivity, two prostate and two thoracic step‐and‐shoot IMRT patients were investigated. Errors introduced to each of the treatment plans included energy switched from 6 MV to 10 MV, multileaf collimator (MLC) leaf errors, linac jaws errors, monitor unit (MU) errors, MLC and gantry angle errors, and detector shift errors. QA was performed on each plan using a single ion chamber and 2D array of ion chambers for 2D and 3D QA. Based on the measurements performed, we established a uniform set of tolerance levels to determine if QA passes for each IMRT treatment plan structure: maximum allowed AADD is 6%; maximum 4% of any structure volume can be with ADD6 greater than 6%, and maximum 4% of any structure volume may fail 3D gamma test with test parameters 3%/3 mm DTA. Out of the three QA methods tested the single ion chamber performed the worst by detecting 4 out of 18 introduced errors, 2D QA detected 11 out of 18 errors, and 3D QA detected 14 out of 18 errors. PACS number: 87.56.Fc PMID:26699299
Stamenova, Vess; Nicola, Raneen; Aharon-Peretz, Judith; Goldsher, Dorith; Kapeliovich, Michael; Gilboa, Asaf
2018-05-01
To examine the effects of brief hypoxia (<7 min) due to cardiac arrest on the integrity of the brain and performance on memory and executive functions tasks. Patients after out-of-hospital cardiac arrest (CA) (n = 9), who were deemed neurologically intact on discharge, were compared to matched patients with myocardial infarction (MI) (n = 9). A battery of clinical and experimental memory and executive functions neuropsychological tests were administered and MRI scans for all patients were collected. Measures of subcortical and cortical volumes and cortical thickness were obtained using FreeSurfer. Manual segmentations of the hippocampus were also performed. APACHE-II scores were calculated based on metrics collected at admission to ICCU for all patients. Significant differences between the two groups were observed on several verbal memory tests. Both hippocampi were significantly reduced (p < 0.05) in the CA patients, relative to MI patients. Hippocampal subfields segmentation showed significantly reduced presubiculum volumes bilaterally. CA patients had on average 10% reduction in volumes bilaterally across hippocampal subfields. No cortical thickness differences survived correction. Significant correlations were observed in the CA group only between the hippocampal volumes and performance on verbal memory tasks, including recollection. Hippocampal volumes and several memory measures (but not other cognitive domains) were strongly correlated with APACHE-II scores on admission in the CA group, but not in the MI group CONCLUSIONS: Chronic patients with cardiac arrest who were discharged from hospital in "good neurological condition" showed an average of 10% reduction in hippocampal volume bilaterally and significant verbal memory deficits relative to matched controls with myocardial infarction, suggesting even brief hypoxic periods suffice to lead to specific hippocampal damage. Copyright © 2018 Elsevier B.V. All rights reserved.
Arhan, Ebru; Gücüyener, Kıvılcım; Soysal, Şebnem; Şalvarlı, Şafak; Gürses, M Ali; Serdaroğlu, Ayşe; Demir, Ercan; Ergenekon, Ebru; Türkyılmaz, Canan; Önal, Esra; Koç, Esin; Atalay, Yıldız
2017-08-01
More information is needed on "low-risk" preterm infants' neurological outcome so that they can be included in follow-up programs. A prospective study was performed to examine the regional brain volume changes compared to term children and to assess the relationship between the regional brain volumes to cognitive outcome of the low-risk preterm children at 9 years of age. Subjects comprised 22 preterm children who were determined to be at low risk for neurodevelopmental deficits with a gestational age between 28 and 33 weeks without a major neonatal morbidity in the neonatal period and 24 age-matched term control children term and matched for age, sex, and parental educational and occupational status. Regional volumetric analysis was performed for cerebellum, hippocampus, and corpus callosum area. Cognitive outcomes of both preterm and control subjects were assessed by Weschler Intelligence Scale for Children Revised (Turkish version), and attention and executive functions were assessed by Wisconsin Card Sorting Test and Stroop Test TBAG version. Low-risk preterm children showed regional brain volume reduction in cerebellum, hippocampus, and corpus callosum area and achieved statistical significance when compared with term control. When the groups were compared for all WISC-R subscale scores, preterm children at low risk had significantly lower scores on information, vocabulary, similarities, arithmetics, picture completion, block design, object assembly, and coding compared to children born at term. Preterm and term groups were compared on the Stroop Test for mistakes and corrections made on each card, the time spent for completing each card, and total mistakes and corrections. In the preterm group, we found a positive correlation between regional volumes with IQ, attention, and executive function scores. Additionally, a significant correlation was found between cerebellar volume and attention and executive function scores in the preterm group. Low-risk preterm children achieve lower scores in neurophysiological tests than children born at term. Preterm birth itself has a significant impact on regional brain volumes and cognitive outcome of children at 9 years of age. It is a risk factor for regional brain volume reductions in preterm children with low risk for neurodevelopmental deficits. The significant interaction between cerebellar volume reduction and executive function and attention may suggest that even in preterm children at low risk can have different trajectories in the growth and development of overall brain structure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dreier, J.; Huggenberger, M.; Aubert, C.
1996-08-01
The PANDA test facility at PSI in Switzerland is used to study the long-term Simplified Boiling Water Reactor (SBWR) Passive Containment Cooling System (PCCS) performance. The PANDA tests demonstrate performance on a larger scale than previous tests and examine the effects of any non-uniform spatial distributions of steam and non-condensables in the system. The PANDA facility has a 1:1 vertical scale, and 1:25 ``system`` scale (volume, power, etc.). Steady-state PCCS condenser performance tests and extensive facility characterization tests have been completed. Transient system behavior tests were conducted late in 1995; results from the first three transient tests (M3 series) aremore » reviewed. The first PANDA tests showed that the overall global behavior of the SBWR containment was globally repeatable and very favorable; the system exhibited great ``robustness.``« less
Cerebellum and cognition in multiple sclerosis: the fall status matters.
Kalron, Alon; Allali, Gilles; Achiron, Anat
2018-04-01
Cerebellar volume has been linked with cognitive performances in MS; however, the association in terms of fall status has never been compared. Therefore, the objective of the current study was to compare cognitive performance with cerebellar volume between MS fallers and non-fallers. The cross-sectional study included 140 PwMS (96 women). MRI volumetric analysis was based on the FreeSurfer image analysis suite. Volumes of the cerebellar gray and white matter were identified as the region of interest. Cognitive function included scores obtained from a computerized cognitive battery of tests. The sample was divided into fallers and non-fallers. MS fallers demonstrated a lower global cognitive performance and reduced gray and white matter cerebellar volumes compared to non-fallers. A significant association was found between total gray and white matter cerebellar volume and visual spatial subdomain (P value = 0.044 and 0.032, respectively) in the non-fallers group. The association remained significant after controlling for the total cranial volume and neurological disability (P value = 0.026 and 0.047, respectively). A relationship was found between the visual spatial score and the left gray matter cerebellum volume; R 2 = 0.44, P value = 0.021. We believe that a unique relationship exists between the cerebellum structure and cognitive processing according to fall history in PwMS and should be considered when investigating the association between brain functioning and cognitive performances in MS.
Reichel, J M; Bedenk, B T; Czisch, M; Wotjak, C T
2017-01-01
Even in the absence of neurodegenerative diseases, progressing age often coincides with cognitive decline and morphological changes. However, longitudinal studies that directly link these two processes are missing. In this proof-of-concept study we therefore performed repeated within-subject testing of healthy male R26R mice in a spatial learning task in combination with manganese-enhanced volumetric MRI analyses at the ages of 8, 16, and 24 months. We grouped the mice into good and poor performers (n = 6, each), based on their spatial learning abilities at the age of 24 months. Using this stratification, we failed to detect a priori volume differences, but observed a significant decrease in total hippocampal volume over time for both groups. Interestingly, this volume decrease was specific for the dorsal hippocampus and significantly accelerated in poor performers between 16 and 24 months of age. This is the first time that individual changes in hippocampal volume were traced alongside cognitive performance within the same subjects over 1½ years. Our study points to a causal link between volume loss of the dorsal hippocampus and cognitive impairments. In addition, it suggests accelerated degenerative processes rather than a priori volume differences as determining trajectories of age-related cognitive decline. Despite the relatively small sample sizes, the strong behavioral and moderate morphological alterations demonstrate the general feasibility of longitudinal studies of age-related decline in cognition and hippocampus integrity. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
An assessment of the variability in performance of wet atmospheric deposition samplers
Graham, R.C.; Robertson, J.K.; Obal, John
1987-01-01
The variability in performance of two brands of wet/dry atmospheric deposition samplers were compared for 1 year at a sincle site. A total of nine samplers were used. Samples were collected weekly and analyzed for pH, specific conductance, common chemical constituents, and sample volume. Additionally, data on the duration of each sampler opening were recorded using a microdatalogger. These data disprove the common perception that samplers remain open throughout a precipitation event. The sensitivity of sampler sensors within the range tested did not have a defineable impact on sample collection. The nonnormal distribution within the data set necessitated application of the nonparametric Friedman Test to assess comparability of sample chemical composition and volume between and within sampler brands. Statistically significant differences existed for most comparisons, however the test did not permit quantification of their magnitudes. Differences in analyte concentrations between samplers were small. (USGS)
ERIC Educational Resources Information Center
Foster, Bruce E., Ed.
Volume 1 contains all the invited papers accepted for the symposium. The subject matter covered in the papers includes physiological, anthropometrical, psychological, sociological, and economic human requirements and methods of evaluation; physical requirements and methods of evaluation in mechanical, acoustical, thermal, dimensional stability,…
Inter-method Performance Study of Tumor Volumetry Assessment on Computed Tomography Test-retest Data
Buckler, Andrew J.; Danagoulian, Jovanna; Johnson, Kjell; Peskin, Adele; Gavrielides, Marios A.; Petrick, Nicholas; Obuchowski, Nancy A.; Beaumont, Hubert; Hadjiiski, Lubomir; Jarecha, Rudresh; Kuhnigk, Jan-Martin; Mantri, Ninad; McNitt-Gray, Michael; Moltz, Jan Hendrik; Nyiri, Gergely; Peterson, Sam; Tervé, Pierre; Tietjen, Christian; von Lavante, Etienne; Ma, Xiaonan; Pierre, Samantha St.; Athelogou, Maria
2015-01-01
Rationale and objectives Tumor volume change has potential as a biomarker for diagnosis, therapy planning, and treatment response. Precision was evaluated and compared among semi-automated lung tumor volume measurement algorithms from clinical thoracic CT datasets. The results inform approaches and testing requirements for establishing conformance with the Quantitative Imaging Biomarker Alliance (QIBA) CT Volumetry Profile. Materials and Methods Industry and academic groups participated in a challenge study. Intra-algorithm repeatability and inter-algorithm reproducibility were estimated. Relative magnitudes of various sources of variability were estimated using a linear mixed effects model. Segmentation boundaries were compared to provide a basis on which to optimize algorithm performance for developers. Results Intra-algorithm repeatability ranged from 13% (best performing) to 100% (least performing), with most algorithms demonstrating improved repeatability as the tumor size increased. Inter-algorithm reproducibility determined in three partitions and found to be 58% for the four best performing groups, 70% for the set of groups meeting repeatability requirements, and 84% when all groups but the least performer were included. The best performing partition performed markedly better on tumors with equivalent diameters above 40 mm. Larger tumors benefitted by human editing but smaller tumors did not. One-fifth to one-half of the total variability came from sources independent of the algorithms. Segmentation boundaries differed substantially, not just in overall volume but in detail. Conclusions Nine of the twelve participating algorithms pass precision requirements similar to what is indicated in the QIBA Profile, with the caveat that the current study was not designed to explicitly evaluate algorithm Profile conformance. Change in tumor volume can be measured with confidence to within ±14% using any of these nine algorithms on tumor sizes above 10 mm. No partition of the algorithms were able to meet the QIBA requirements for interchangeability down to 10 mm, though the partition comprised of the best performing algorithms did meet this requirement above a tumor size of approximately 40 mm. PMID:26376841
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1997-10-01
Horizontal axis (H-axis) clothes washers use less water and energy than conventional top-loading vertical axis (V-axis) clothes washers, yet sales in the US are insignificant. In the High Efficiency Laundry Metering and Market Analysis (THELMA) project, EPRI and a group of utilities have pooled their resources to develop the basis for successful DSM programs to accelerate the acceptance of this technology in the US market. This report covers the laboratory test phase of the THELMA project. The objective of this effort was to measure the performance of a representative sample of currently manufactured H-axis washers and to compare this performancemore » to that of a typical V-axis washer. Several aspects of performance were measured, with the emphasis on measures of energy consumption and water consumption: DOE washer capacity; hot and cold water consumption; energy consumption by the washer mechanical drive; DOE energy factor; water extraction effectiveness; effect of water extraction effectiveness on dryer energy; soil removal effectiveness; rinsing effectiveness; and gentleness of action. Eight H-axis washers, provided by US or European manufacturers, were tested. Test results varied over a range for these eight machines, but on average, the H-axis washers used 40% less energy (normalized to basket volume) and 25% less water (normalized to basket volume) when measured according to the DOE test procedure.« less
Treatment of Perfluorinated Alkyl Substances in Wash Water ...
Report The U.S. Environmental Protection Agency’s (EPA) National Homeland Security Research Center partnered with the Idaho National Laboratory (INL) to build the Water Security Test Bed (WSTB) at the INL test site outside of Idaho Falls, Idaho. This report summarizes the results from testing conducted to evaluate the treatment of large volumes of water containing perfluorinated alkyl substances (PFAS). This summary of conclusions and observations about the performance and implementation of adsorptive treatment of AFFF contaminated water, based on the testing performed at the INL WSTB.
40 CFR 86.101 - General applicability.
Code of Federal Regulations, 2014 CFR
2014-07-01
... procedures. For example, if you are testing an ethanol-fueled vehicle, perform diagnostics in your evaporative emission enclosure with ethanol and propane. (9) For exhaust emission testing with ethanol-gasoline blends that have less than 25% ethanol by volume, if you use NMHC-to-NMOG conversion factors...
DOT National Transportation Integrated Search
1999-03-01
The Mobile Surveillance and Wireless Communication Systems Field Operational Test (FOT) evaluated the performance of wireless traffic detection and communications systems in areas where permanent detectors, electrical power, and landline communicatio...
Examination of space/volume requirements for US underground coal mine refuge alternatives.
Porter, William L; Dempsey, Patrick G; Jansky, Jacqueline H
2017-01-01
The Mine Safety and Health Administration requires that 1.4 m 2 (15 ft 2 ) of floor space is to be provided for each person inside a refuge alternative (RA). However, the amount of floor space needed for a person to reside inside an RA and perform basic tasks is unknown. During testing, participants entered into an RA or a simulated RA of various space/volume configurations and performed several simulated tasks that are representative of the survivability tasks performed within an RA. The results indicate that the floor space requirements were generally adequate for the tasks studied. Certain tasks such as changing scrubber cartridges, using toilets, and moving about the RA were impacted by the minimum height tested (0.6 m). As such, RAs of this height will require critical design consideration as a whole and the supplies provided for use inside of the RA to ensure the ability to use an RA.
Thomas, Marianna S; Newman, David; Leinhard, Olof Dahlqvist; Kasmai, Bahman; Greenwood, Richard; Malcolm, Paul N; Karlsson, Anette; Rosander, Johannes; Borga, Magnus; Toms, Andoni P
2014-09-01
To measure the test-retest reproducibility of an automated system for quantifying whole body and compartmental muscle volumes using wide bore 3 T MRI. Thirty volunteers stratified by body mass index underwent whole body 3 T MRI, two-point Dixon sequences, on two separate occasions. Water-fat separation was performed, with automated segmentation of whole body, torso, upper and lower leg volumes, and manually segmented lower leg muscle volumes. Mean automated total body muscle volume was 19·32 L (SD9·1) and 19·28 L (SD9·12) for first and second acquisitions (Intraclass correlation coefficient (ICC) = 1·0, 95% level of agreement -0·32-0·2 L). ICC for all automated test-retest muscle volumes were almost perfect (0·99-1·0) with 95% levels of agreement 1.8-6.6% of mean volume. Automated muscle volume measurements correlate closely with manual quantification (right lower leg: manual 1·68 L (2SD0·6) compared to automated 1·64 L (2SD 0·6), left lower leg: manual 1·69 L (2SD 0·64) compared to automated 1·63 L (SD0·61), correlation coefficients for automated and manual segmentation were 0·94-0·96). Fully automated whole body and compartmental muscle volume quantification can be achieved rapidly on a 3 T wide bore system with very low margins of error, excellent test-retest reliability and excellent correlation to manual segmentation in the lower leg. Sarcopaenia is an important reversible complication of a number of diseases. Manual quantification of muscle volume is time-consuming and expensive. Muscles can be imaged using in and out of phase MRI. Automated atlas-based segmentation can identify muscle groups. Automated muscle volume segmentation is reproducible and can replace manual measurements.
Teeter, Matthew G; Langohr, G Daniel G; Medley, John B; Holdsworth, David W
2014-02-01
The purpose of this study was to determine the ability of micro-computed tomography to quantify wear in preclinical pin-on-plate testing of materials for use in joint arthroplasty. Wear testing of CoCr pins articulating against six polyetheretherketone plates was performed using a pin-on-plate apparatus over 2 million cycles. Change in volume due to wear was quantified with gravimetric analysis and with micro-computed tomography, and the volumes were compared. Separately, the volume of polyetheretherketone pin-on-plate specimens that had been soaking in fluid for 52 weeks was quantified with both gravimetric analysis and micro-computed tomography, and repeated after drying. The volume change with micro-computed tomography was compared to the mass change with gravimetric analysis. The mean wear volume measured was 8.02 ± 6.38 mm(3) with gravimetric analysis and 6.76 ± 5.38 mm(3) with micro-computed tomography (p = 0.06). Micro-computed tomography volume measurements did not show a statistically significant change with drying for either the plates (p = 0.60) or the pins (p = 0.09), yet drying had a significant effect on the gravimetric mass measurements for both the plates (p = 0.03) and the pins (p = 0.04). Micro-computed tomography provided accurate measurements of wear in polyetheretherketone pin-on-plate test specimens, and no statistically significant change was caused by fluid uptake. Micro-computed tomography quantifies wear depth and wear volume, mapped to the specific location of damage on the specimen, and is also capable of examining subsurface density as well as cracking. Its noncontact, nondestructive nature makes it ideal for preclinical testing of materials, in which further additional analysis techniques may be utilized.
Reserve Li/SOC12 Battery Safety Testing
NASA Technical Reports Server (NTRS)
Dils, C. T.; Garoutte, K. F.
1984-01-01
A reserve Lithium/Thionyl Chloride Battery concept is developed and undergoing feasibility testing in terms of performance, safety and abusive conditions. The feasibility of employing a battery of this type to replace thermal batteries in certain applications is demonstrated. Excellent performance of a Li/SOCl2 reserve battery is obtained across the temperature range from 0 C to +44 C. Performance improvement over the thermal battery usage is greater by a factor of 3 when discharge time and energy density are compared. Performance over an expanded temperature range is also possible. Safety and abusive testing is accomplished successfully on a series of five units. Further performance improvements can be achieved with regard to battery weight and volume reductions.
NASA Technical Reports Server (NTRS)
Csomor, A.
1974-01-01
Rotating and positive displacement pumps of various types were studied for pumping liquid fluorine for low thrust high performance rocket engines. Included in the analysis were: centrifugal, pitot, Barske, Tesla, drag, gear, vane, axial piston, radial piston, diaphragm and helirotor pump concepts. The centrifugal and gear pumps were carried through detail design and fabrication. After preliminary testing in Freon 12, the centrifugal pump was selected for further testing and development. It was tested in Freon 12 to obtain the hydrodynamic performance. Tests were also conducted in liquid fluorine to demonstrate chemical compatibility.
Relationships between cognitive performance, neuroimaging, and vascular disease: the DHS-Mind Study
Hsu, Fang-Chi; Raffield, Laura M.; Hugenschmidt, Christina E.; Cox, Amanda; Xu, Jianzhao; Carr, J. Jeffery; Freedman, Barry I.; Maldjian, Joseph A.; Williamson, Jeff D.; Bowden, Donald W.
2015-01-01
Background Type 2 diabetes mellitus increases risk for cognitive decline and dementia; elevated burdens of vascular disease are hypothesized to contribute to this risk. These relationships were examined in the Diabetes Heart Study-Mind using a battery of cognitive tests, neuroimaging measures, and subclinical cardiovascular disease (CVD) burden assessed by coronary artery calcified plaque (CAC). We hypothesized that CAC would attenuate the association between neuroimaging measures and cognition performance. Methods Associations were examined using marginal models in this family-based cohort of 572 European Americans from 263 families. All models were adjusted for age, gender, education, type 2 diabetes, and hypertension, with some neuroimaging measures additionally adjusted for intracranial volume. Results Higher total brain volume (TBV) was associated with better performance on the Digit Symbol Substitution Task (DSST) and Semantic Fluency (both p≤7.0 x 10−4). Higher gray matter volume (GMV) was associated with better performance on the Modified Mini-Mental State Examination and Semantic Fluency (both p≤9.0 x 10−4). Adjusting for CAC caused minimal changes to the results. Conclusions Relationships exist between neuroimaging measures and cognitive performance in a type 2 diabetes-enriched European American cohort. Associations were minimally attenuated after adjusting for subclinical CVD. Additional work is needed to understand how subclinical CVD burden interacts with other factors and impacts relationships between neuroimaging and cognitive testing measures. PMID:26185004
Hsu, Fang-Chi; Sink, Kaycee M; Hugenschmidt, Christina E; Williamson, Jeff D; Hughes, Timothy M; Palmer, Nicholette D; Xu, Jianzhao; Smith, S Carrie; Wagner, Benjamin C; Whitlow, Christopher T; Bowden, Donald W; Maldjian, Joseph A; Divers, Jasmin; Freedman, Barry I
2018-03-02
African Americans typically perform worse than European Americans on cognitive testing. Contributions of cardiovascular disease (CVD) risk factors and educational quality to cognitive performance and brain volumes were compared in European Americans and African Americans with type 2 diabetes. Association between magnetic resonance imaging-determined cerebral volumes of white matter (WMV), gray matter (GMV), white matter lesions (WMLV), hippocampal GMV, and modified mini-mental state exam (3MSE), digit symbol coding (DSC), Rey Auditory Verbal Learning Test (RAVLT), Stroop, and verbal fluency performance were assessed in Diabetes Heart Study Memory in Diabetes (MIND) participants. Marginal models incorporating generalized estimating equations were employed with serial adjustment for risk factors. The sample included 520 African Americans and 684 European Americans; 56 per cent female with mean ± SD age 62.8 ± 10.3 years and diabetes duration 14.3 ± 7.8 years. Adjusting for age, sex, diabetes duration, BMI, HbA1c, total intracranial volume, scanner, statins, CVD, smoking, and hypertension, WMV (p = .001) was lower and WMLV higher in African Americans than European Americans (p = .001), with similar GMV (p = .30). Adjusting for age, sex, education, HbA1c, diabetes duration, hypertension, BMI, statins, CVD, smoking, and depression, poorer performance on 3MSE, RAVLT, and DSC were seen in African Americans (p = 6 × 10-23-7 × 10-62). Racial differences in cognitive performance were attenuated after additional adjustment for WMLV and nearly fully resolved after adjustment for wide-range achievement test (WRAT) performance (p = .0009-.65). African Americans with type 2 diabetes had higher WMLV and poorer cognitive performance than European Americans. Differences in cognitive performance were attenuated after considering WMLV and apparent poorer educational quality based on WRAT. © The Author(s) 2018. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Portable Low-Volume Therapy for Severe Blood Loss
2013-06-01
with Tukey’s post hoc test were performed to find treatment differences within different time points for total hemoglobin (tHb), pH, pressure of...Tukey’s post hoc test were performed to find treatment differences within time points. No correlation was observed for any of the parameters at any...Department of the Army position, policy or decision unless so designated by other documentation. REPORT DOCUMENTATION PAGE Form Approved OMB
AGT 1500 Powerpack Improvement Project (M1 TMEPS). Volume 1
1991-03-01
culminated in a one week evalUation of the ATR. This was due to funding and schedule constraints. Testing was concentrated on vehicle mobility performance...June 1990 with a one week vehicle demonstration at Milford Proving Grounds. The vehicle performed well but the mobility characteristics, most...all of the nonrecurring, recurring, engineering, data, system test and evaluation, and initial spares costs aplicable to each alternative. TMEPS as a
NASA Astrophysics Data System (ADS)
Jadhav, Shital; Powar, Amit; Patil, Sandip; Supare, Ashish; Farane, Bhagwan; Singh, Rajkumar, Dr.
2017-05-01
The present study was performed to investigate the effect of volume fraction of alpha and transformed beta phase on the high-cycle fatigue (HCF) properties of the bimodal titanium Ti6Al4V alloy. The effect of such morphology on mechanical properties was studied using tensile and rotating bending fatigue test as per ASTM standards. Microstructures and fractography of the specimens were studied using optical and scanning electron microscopy (SEM) respectively.Ti6Al4V alloy samples were heat treated to have three distinctive volume fractions of alpha and transformed beta phase. With an increase in quench delay from 30,50 and 70 sec during quenching after solutionizing temperature of 967°C, the volume fraction of alpha was found to be increased from 20% to 67%. Tests on tensile and rotating bending fatigue showed that the specimen with 20% volume fraction of alpha phase exhibited the highest tensile and fatigue strength, however the properties gets deteriorate with increase in volume fraction of alpha.
Market assessment of tuberculosis diagnostics in China in 2012.
Zhao, Y-L; Pang, Y; Xia, H; Du, X; Chin, D; Huan, S-T; Dong, H-Y; Zhang, Z-Y; Ginnard, J; Perkins, M D; Boehme, C C; Jefferson, C; Pantoja, A; Qin, Z Z; Chedore, P; Denkinger, C M; Pai, M; Kik, S V
2016-03-01
To assess the 2012 served available market for tuberculosis (TB) diagnostics in China in the sector served by the China Centre for Disease Control and Prevention (CDC) and the hospital sector in China, including both designated TB hospitals and general hospitals. Test volumes and unit costs were assessed for tuberculin skin tests, interferon-gamma release assays (IGRAs), smear microscopy, serology, cultures, speciation tests, nucleic-acid amplification tests (NAATs), drug susceptibility tests and adenosine-deaminase tests (ADA). Data were obtained from electronic databases (CDC sector) and through surveys (hospital sector), and were estimated for the two sectors and for the country as a whole. Test costs were estimated by staff at China CDC, and using published literature. In 2012, the China CDC and hospital sectors performed a total of 44 million TB diagnostic tests at an overall value of US$294 million. Tests used by the CDC sector were smear microscopy, solid and liquid culture and DST, while the hospital sector also used IGRAs, NAATs, ADA and serology. The hospital sector accounted for 76% of the overall test volume and 94% of the market value. China has a very large TB diagnostic market that encompasses a wide range of diagnostic tests, with the majority being performed in Chinese hospitals.
Casas, Rafael; Muthusamy, Siva; Wakim, Paul G; Sinharay, Sanhita; Lentz, Margaret R; Reid, William C; Hammoud, Dima A
2018-01-01
HIV infection is known to be associated with brain volume loss, even in optimally treated patients. In this study, we assessed whether dynamic brain volume changes over time are predictive of neurobehavorial performance in the HIV-1 transgenic (Tg) rat, a model of treated HIV-positive patients. Cross-sectional brain MRI imaging was first performed comparing Tg and wild type (WT) rats at 3 and 19 months of age. Longitudinal MRI and neurobehavioral testing of another group of Tg and WT rats was then performed from 5 to 23 weeks of age. Whole brain and subregional image segmentation was used to assess the rate of brain growth over time. We used repeated-measures mixed models to assess differences in brain volumes and to establish how predictive the volume differences are of specific neurobehavioral deficits. Cross-sectional imaging showed smaller whole brain volumes in Tg compared to WT rats at 3 and at 19 months of age. Longitudinally, Tg brain volumes were smaller than age-matched WT rats at all time points, starting as early as 5 weeks of age. The Tg striatal growth rate delay between 5 and 9 weeks of age was greater than that of the whole brain. Striatal volume in combination with genotype was the most predictive of rota-rod scores and in combination with genotype and age was the most predictive of total exploratory activity scores in the Tg rats. The disproportionately delayed striatal growth compared to whole brain between 5 and 9 weeks of age and the role of striatal volume in predicting neurobehavioral deficits suggest an important role of the dopaminergic system in HIV associated neuropathology. This might explain problems with motor coordination and executive decisions in this animal model. Smaller brain and subregional volumes and neurobehavioral deficits were seen as early as 5 weeks of age, suggesting an early brain insult in the Tg rat. Neuroprotective therapy testing in this model should thus target this early stage of development, before brain damage becomes irreversible.
The impact of surface area, volume, curvature, and Lennard-Jones potential to solvation modeling.
Nguyen, Duc D; Wei, Guo-Wei
2017-01-05
This article explores the impact of surface area, volume, curvature, and Lennard-Jones (LJ) potential on solvation free energy predictions. Rigidity surfaces are utilized to generate robust analytical expressions for maximum, minimum, mean, and Gaussian curvatures of solvent-solute interfaces, and define a generalized Poisson-Boltzmann (GPB) equation with a smooth dielectric profile. Extensive correlation analysis is performed to examine the linear dependence of surface area, surface enclosed volume, maximum curvature, minimum curvature, mean curvature, and Gaussian curvature for solvation modeling. It is found that surface area and surfaces enclosed volumes are highly correlated to each other's, and poorly correlated to various curvatures for six test sets of molecules. Different curvatures are weakly correlated to each other for six test sets of molecules, but are strongly correlated to each other within each test set of molecules. Based on correlation analysis, we construct twenty six nontrivial nonpolar solvation models. Our numerical results reveal that the LJ potential plays a vital role in nonpolar solvation modeling, especially for molecules involving strong van der Waals interactions. It is found that curvatures are at least as important as surface area or surface enclosed volume in nonpolar solvation modeling. In conjugation with the GPB model, various curvature-based nonpolar solvation models are shown to offer some of the best solvation free energy predictions for a wide range of test sets. For example, root mean square errors from a model constituting surface area, volume, mean curvature, and LJ potential are less than 0.42 kcal/mol for all test sets. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
VOLUMETRIC LEAK DETECTION IN LARGE UNDERGROUND STORAGE TANKS - VOLUME II: APPENDICES A-E
The program of experiments conducted at Griffiss Air Force Base was devised to expand the understanding of large underground storage tank behavior as it impacts the performance of volumetric leak detection testing. The report addresses three important questions about testing the ...
NASA Technical Reports Server (NTRS)
1977-01-01
The joint U.S.-USSR experiments and the U.S. conducted unilateral experiments performed during the Apollo Soyuz Test Project are described. Scientific concepts and experiment design and operation are discussed along with scientific results of postflight analysis.
DOT National Transportation Integrated Search
1979-01-01
The Standard Light Rail Vehicle (SLRV) is a 71-foot vehicle, articulated to negotiate curves down to 32-foot radius and designed to operate at speeds up to 50 mph. Although the basic configuration and performance is standardized, the current operatin...
Cella, Laura; Liuzzi, Raffaele; Conson, Manuel; D'Avino, Vittoria; Salvatore, Marco; Pacelli, Roberto
2012-12-27
Hypothyroidism is a frequent late side effect of radiation therapy of the cervical region. Purpose of this work is to develop multivariate normal tissue complication probability (NTCP) models for radiation-induced hypothyroidism (RHT) and to compare them with already existing NTCP models for RHT. Fifty-three patients treated with sequential chemo-radiotherapy for Hodgkin's lymphoma (HL) were retrospectively reviewed for RHT events. Clinical information along with thyroid gland dose distribution parameters were collected and their correlation to RHT was analyzed by Spearman's rank correlation coefficient (Rs). Multivariate logistic regression method using resampling methods (bootstrapping) was applied to select model order and parameters for NTCP modeling. Model performance was evaluated through the area under the receiver operating characteristic curve (AUC). Models were tested against external published data on RHT and compared with other published NTCP models. If we express the thyroid volume exceeding X Gy as a percentage (Vx(%)), a two-variable NTCP model including V30(%) and gender resulted to be the optimal predictive model for RHT (Rs = 0.615, p < 0.001. AUC = 0.87). Conversely, if absolute thyroid volume exceeding X Gy (Vx(cc)) was analyzed, an NTCP model based on 3 variables including V30(cc), thyroid gland volume and gender was selected as the most predictive model (Rs = 0.630, p < 0.001. AUC = 0.85). The three-variable model performs better when tested on an external cohort characterized by large inter-individuals variation in thyroid volumes (AUC = 0.914, 95% CI 0.760-0.984). A comparable performance was found between our model and that proposed in the literature based on thyroid gland mean dose and volume (p = 0.264). The absolute volume of thyroid gland exceeding 30 Gy in combination with thyroid gland volume and gender provide an NTCP model for RHT with improved prediction capability not only within our patient population but also in an external cohort.
Marzocca, A J; Cerveny, S; Salgueiro, W; Somoza, A; Gonzalez, L
2002-02-01
An experimental investigation was performed to study the effect on the free volume of the advance of the cross-linking reaction in a copolymer of styrene butadiene rubber by sulfur vulcanization. The dynamic modulus and loss tangent were evaluated over samples cured for different times at 433 K by dynamic mechanical tests over a range of frequencies between 5 and 80 Hz at temperatures between 200 and 300 K. Using the William-Landel-Ferry relationship, master curves were obtained at a reference temperature of 298 K and the coefficients c(0)(1) and c(0)(2) were evaluated. From these parameters the dependence of the free volume on the cure time is obtained. Positron annihilation lifetime spectroscopy was also used to estimate the size and number density of free volume sites in the material. The spectra were analyzed in terms of continuous distributions of free volume size. The results suggest an increase of the lower free volume size when cross linking takes place. Both techniques give similar results for the dependence of free volume on the time of cure of the polymer.
42 CFR 493.643 - Fee for determination of program compliance.
Code of Federal Regulations, 2013 CFR
2013-10-01
... sets the fee amounts annually on a calendar year basis. Laboratories are inspected biennially... additional fee is based on the actual resources and time necessary to perform the activities. (c..., and proficiency testing purposes). (i) (A) Schedule A Low Volume. The laboratory performs not more...
42 CFR 493.643 - Fee for determination of program compliance.
Code of Federal Regulations, 2012 CFR
2012-10-01
... sets the fee amounts annually on a calendar year basis. Laboratories are inspected biennially... additional fee is based on the actual resources and time necessary to perform the activities. (c..., and proficiency testing purposes). (i) (A) Schedule A Low Volume. The laboratory performs not more...
42 CFR 493.643 - Fee for determination of program compliance.
Code of Federal Regulations, 2014 CFR
2014-10-01
... sets the fee amounts annually on a calendar year basis. Laboratories are inspected biennially... additional fee is based on the actual resources and time necessary to perform the activities. (c..., and proficiency testing purposes). (i) (A) Schedule A Low Volume. The laboratory performs not more...
DOT National Transportation Integrated Search
2013-10-01
The performance of a microwave radar system for vehicle detection at a railroad grade crossing in Hinsdale, : Illinois, was evaluated through field-testing in favorable (normal, good) weather conditions. The system was : installed at a crossing with ...
DOT National Transportation Integrated Search
2013-03-01
This project developed and evaluated four new asphalt concrete (AC) mixtures that use locally available : aggregates whenever possible with the ultimate goal of a cost-effective mixture that also improves pavement : performance. Although numerous tac...
Casaletto, Kaitlin B.; Ward, Michael E.; Baker, Nicholas S.; Bettcher, Brianne M.; Gelfand, Jeffrey M.; Li, Yaqiao; Chen, Robert; Dutt, Shubir; Miller, Bruce; Kramer, Joel H.; Green, Ari J.
2017-01-01
Given the converging pathologic and epidemiologic data indicating a relationship between retinal integrity and neurodegeneration, including Alzheimer’s disease (AD), we aimed to determine if retinal structure correlates with medial temporal lobe (MTL) structure and function in neurologically normal older adults. Spectral-domain optical coherence tomography, verbal and visual memory testing, and 3T-magnetic resonance imaging of the brain were performed in 79 neurologically normal adults enrolled in a healthy aging cohort study. Retinal nerve fiber thinning and reduced total macular and macular ganglion cell volumes were each associated with smaller MTL volumes (ps < 0.04). Notably, these markers of retinal structure were not associated with primary motor cortex or basal ganglia volumes (regions relatively unaffected in AD) (ps > 0.70), or frontal, precuneus, or temporoparietal volumes (regions affected in later AD Braak staging ps > 0.20). Retinal structure was not significantly associated with verbal or visual memory consolidation performances (ps > 0.14). Retinal structure was associated with MTL volumes, but not memory performances, in otherwise neurologically normal older adults. Given that MTL atrophy is a neuropathological hallmark of AD, retinal integrity may be an early marker of ongoing AD-related brain health. PMID:28068565
NASA Technical Reports Server (NTRS)
Finger, R. W.
1978-01-01
Static fracture tests were performed on surface flawed specimens of aluminum and titanium alloys. A simulated proof overload cycle was applied prior to all of the cyclic tests. Variables included in each test series were flaw shapes and thickness. Additionally, test temperature was a variable for the aluminum test series. The crack opening displacement and stress-strain data obtained are presented.
Koo, Min-Seong; Levitt, James J.; McCarley, Robert W.; Seidman, Larry J.; Dickey, Chandlee C.; Niznikiewicz, Margaret A.; Voglmaier, Martina M.; Zamani, Payman; Long, Katherine R.; Kim, Sunnie S.; Shenton, Martha E.
2009-01-01
Background The caudate nucleus might contribute to the psychopathological and cognitive deficits observed in schizotypal personality disorder (SPD), a schizophrenia spectrum disorder. Here we focused on female patients, because this group is underrepresented in studies of SPD and schizophrenia, and we might learn more about the caudate and clinical and cognitive impairments that are unique to female patients diagnosed with SPD. Methods Magnetic resonance imaging scans, obtained on a 1.5-T magnet with 1.5-mm contiguous slices, were used to measure the caudate in 32 neuroleptic-naïve women with SPD and in 29 female normal comparison subjects. Subjects were group-matched for age, parental socioeconomic status, and intelligence quotient. Results We found significantly reduced left and right caudate relative volume (8.3%, 7.7%) in female SPD subjects compared with normal comparison subjects. In female SPD subjects, we found significant correlations between smaller total caudate relative volume and worse performance on the Wisconsin Card Sorting test (nonperseverative errors) and on the California Verbal Learning Test (verbal memory and learning), and significant correlations between smaller total caudate relative volume and both positive and negative symptoms on the Structured Interview for Schizotypy. Conclusions These findings demonstrate that, for female SPD subjects, smaller caudate volume is associated with poorer cognitive performance and more schizotypal symptomatology. PMID:16460694
Mikkelsen, Mark; Singh, Krish D; Brealy, Jennifer A; Linden, David E J; Evans, C John
2016-11-01
The quantification of γ-aminobutyric acid (GABA) concentration using localised MRS suffers from partial volume effects related to differences in the intrinsic concentration of GABA in grey (GM) and white (WM) matter. These differences can be represented as a ratio between intrinsic GABA in GM and WM: r M . Individual differences in GM tissue volume can therefore potentially drive apparent concentration differences. Here, a quantification method that corrects for these effects is formulated and empirically validated. Quantification using tissue water as an internal concentration reference has been described previously. Partial volume effects attributed to r M can be accounted for by incorporating into this established method an additional multiplicative correction factor based on measured or literature values of r M weighted by the proportion of GM and WM within tissue-segmented MRS volumes. Simulations were performed to test the sensitivity of this correction using different assumptions of r M taken from previous studies. The tissue correction method was then validated by applying it to an independent dataset of in vivo GABA measurements using an empirically measured value of r M . It was shown that incorrect assumptions of r M can lead to overcorrection and inflation of GABA concentration measurements quantified in volumes composed predominantly of WM. For the independent dataset, GABA concentration was linearly related to GM tissue volume when only the water signal was corrected for partial volume effects. Performing a full correction that additionally accounts for partial volume effects ascribed to r M successfully removed this dependence. With an appropriate assumption of the ratio of intrinsic GABA concentration in GM and WM, GABA measurements can be corrected for partial volume effects, potentially leading to a reduction in between-participant variance, increased power in statistical tests and better discriminability of true effects. Copyright © 2016 John Wiley & Sons, Ltd.
The Effect of Plyometric Training Volume on Athletic Performance in Prepubertal Male Soccer Players.
Chaabene, Helmi; Negra, Yassine
2017-10-01
To assess and compare the effects of 8 wk of in-season (2 sessions/wk) low- and high-volume plyometric training (PT) on measures of physical fitness in prepubertal male soccer players. A total of 25 soccer players were randomly assigned to a low-volume PT group (LPT; n = 13, age 12.68 ± 0.23 y, age at peak height velocity [APHV] 14.25 ± 0.29 y, maturity offset -1.57 ± 0.29 y) or a high-volume PT group (HPT; n = 12, age 12.72 ± 0.27 y, APHV 14.33 ± 0.77 y, maturity offset -1.61 ± 0.76 y). A linear-sprint test (5-m, 10-m, 20-m, and 30-m), change-of-direction (CoD) test, and vertical- (squat-jump [SJ]), countermovement- (CMJ), and horizontal-jump (standing long jump [SLJ]) test were carried out before and after 8 wk of PT. There was a significant main effect of time for sprint outcomes (5-m, P = .005, ES = 0.86; 10-m, P = .006, ES = 0.85; 20-m, P = .03, ES = 0.64, and 30-m, P = .05, ES = 0.57), CoD (P = .002, ES = 0.96), SJ (P = .008, ES = 0.81; CMJ, P = .01, ES = 0.73), and SLJ ability (P = .007, ES = 0.83). There were no significant training group × time interactions in any measured outcomes. After 8 wk of training, results showed similar performance improvement on measures of sprint time, CoD, and jumping ability between LPT and HPT groups. From a time-efficiency perspective, it is recommended to use LPT in prepubertal male soccer players to improve their proxies of athletic performance.
Exergy analysis of hybrid nanofluids with optimum concentration in a plate heat exchanger
NASA Astrophysics Data System (ADS)
Kumar, Vikas; Tiwari, Arun Kumar; Ghosh, Subrata Kumar
2018-06-01
This paper highlights an investigation on the comparative analyses of exergetic performance with optimum volume concentration of hybrid nanofluids in a plate heat exchanger (PHE). Different types of hybrid nanofluids (Al2O3 + MWCNT/water, TiO2 + MWCNT/water, ZnO + MWCNT/water, and CeO2 + MWCNT/water) as coolant have been tested. Proportion of 0.75% of nanofluid has been found to be the optimum volume concentration. The requisite thermal and physical properties of the hybrid nanofluids were measured at 35 °C. Various exergetic performance parameters have been examined for comparing different hybrid nanofluids. The highest reduction in exergy loss of CeO2 + MWCNT/water hybrid nanofluid has been obtained at a concentration of about 24.75%. Entropy generation decreased with the increase in volume concentration. The results established that CeO2 + MWCNT/water hybrid nanofluid can be a promising coolant for exergetic performances in a PHE.
Factors influencing the measurement of closing volume.
Make, B; Lapp, N L
1975-06-01
The various factors influencing closing volume were studied by performing the single-breath N2 test on 9 healthy nonsmokers. Time of day, day of the week, and preceding volume history had no effect on either closing volume or alveolar plateau. Slow inspiratory flow resulted in larger ratio of closing volume to vital capacity, ratio of closing capacity to total lung capacity, and change in N2 concentration than fast inspiratory flow. Voluntary regulation of the expiratory flow resulted in smaller ratios of closing volume to vital capacity and closing capacity to total lung capacity than when flow was regulated by a resistance. Prolonged breath holding of the inspired O2 led to larger ratio of closing volume to vital capacity and ratio of closing capacity to total lung capacity. To obtain uniform, comparable closing volumes, it is suggested that the subject inspire slowly, control expiratory flow (preferably voluntarily), and not pause between inspiration and expiration.
An automated system for chromosome analysis. Volume 1: Goals, system design, and performance
NASA Technical Reports Server (NTRS)
Castleman, K. R.; Melnyk, J. H.
1975-01-01
The design, construction, and testing of a complete system to produce karyotypes and chromosome measurement data from human blood samples, and a basis for statistical analysis of quantitative chromosome measurement data is described. The prototype was assembled, tested, and evaluated on clinical material and thoroughly documented.
Truck Noise IX : Noise Reduction Study of an In-Service Diesel-Powered Truck : Volume 1. Text.
DOT National Transportation Integrated Search
1977-02-01
A series of tests to measure the noise contributions of subsystems were performed on a truck with a conventional short cab, equipped with a Cummins V-903 engine. The data acquired in these tests were used to select retrofittable components which woul...
DOT National Transportation Integrated Search
1979-02-01
The SLRV (Standard Light Rail Vehicle) is a 71-foot vehicle, articulated to negotiate curves down to a 32-foot radius and designed to operate at speeds up to 50 mph. Although the basic configuration and performance is standardized, the current operat...
The report gives results of field tests conducted to determine the emission characteristics of a Babcock and Wilcox Circular burner and Dual Register burner (DRB). The field tests were performed at two utility boilers, generally comparable in design and size except for the burner...
Truck Noise IX : Noise Reduction Study of an In-Service Diesel Powered Truck : Volume 2. Appendix.
DOT National Transportation Integrated Search
1977-02-01
A series of tests to measure the noise contributions of subsystems were performed on a truck with a conventional short cab, equipped with a Cummins V-903 engine. The data acquired in these tests were used to select retrofittable components which woul...
DOT National Transportation Integrated Search
2000-09-01
The Long Term Pavement Performance (LTPP) program has been collecting profile and : International Roughness Index (IRI) information from more than 2,062 test sections since 1989 : using K.J. Law 690DNC optical sensor Profilometers. Analysis of the IR...
Air STAR Beyond Visual Range UAS Description and Preliminary Test Results
NASA Technical Reports Server (NTRS)
Cunningham, Kevin; Cox, David E.; Foster, John V.; Riddick, Stephen E.; Laughter, Sean A.
2016-01-01
The NASA Airborne Subscale Transport Aircraft Research Unmanned Aerial System project's capabilities were expanded by updating the system design and concept of operations. The new remotely piloted airplane system design was flight tested to assess integrity and operational readiness of the design to perform flight research. The purpose of the system design is to improve aviation safety by providing a capability to validate, in high-risk conditions, technologies to prevent airplane loss of control. Two principal design requirements were to provide a high degree of reliability and that the new design provide a significant increase in test volume (relative to operations using the previous design). The motivation for increased test volume is to improve test efficiency and allow new test capabilities that were not possible with the previous design and concept of operations. Three successful test flights were conducted from runway 4-22 at NASA Goddard Space Flight Center's Wallops Flight Facility.
Agbahiwe, Harold; Rashid, Arif; Horska, Alena; Mahone, E Mark; Lin, Doris; McNutt, Todd; Cohen, Kenneth; Redmond, Kristin; Wharam, Moody; Terezakis, Stephanie
2017-01-01
Cranial radiation therapy (RT) is an important component in the treatment of pediatric brain tumors. However, it can result in long-term effects on the developing brain. This prospective study assessed the effects of cranial RT on cerebral, frontal lobe, and temporal lobe volumes and their correlation with higher cognitive functioning. Ten pediatric patients with primary brain tumors treated with cranial RT and 14 age- and sex-matched healthy children serving as controls were evaluated. Quantitative magnetic resonance imaging and neuropsychological assessments (language, memory, auditory and visual processing, and vocabulary) were performed at the baseline and 6, 15, and 27 months after RT. The effects of age, the time since RT, and the cerebral RT dose on brain volumes and neuropsychological performance were analyzed with linear mixed effects model analyses. Cerebral volume increased significantly with age in both groups (P = .01); this increase in volume was more pronounced in younger children. Vocabulary performance was found to be significantly associated with a greater cerebral volume (P = .05) and a lower RT dose (P = .003). No relation was observed between the RT dose and the cerebral volume. There was no difference in the corresponding neuropsychological tests between the 2 groups. This prospective study found significant relations among the RT dose, cerebral volumes, and rate of vocabulary development among children receiving RT. The results of this study provide further support for clinical trials aimed at reducing cranial RT doses in the pediatric population. Cancer 2017;161-168. © 2016 American Cancer Society. © 2016 American Cancer Society.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kanninen, M.F.; O'Donoghue, P.E.; Popelar, C.F.
1993-02-01
The project was undertaken for the purposes of quantifying the Battelle slow crack growth (SCG) test for predicting long-term performance of polyethylene gas distribution pipes, and of demonstrating the applicability of the methodology for use by the gas industry for accelerated characterization testing, thereby bringing the SCG test development effort to a closure. The work has revealed that the Battelle SCG test, and the linear fracture mechanics interpretation that it currently utilizes, is valid for a class of PE materials. The long-term performance of these materials in various operating conditions can therefore be effectively predicted.
Turner, Arlener D.; Furey, Maura; Drevets, Wayne C.; Zarate, Carlos; Nugent, Allison
2012-01-01
Research has shown poor performance on verbal memory tasks in patients with major depressive disorder relative to healthy controls, as well as structural abnormalities in the subcortical structures that form the limbic-cortical-striatal-pallidal-thalamic circuitry. Few studies, however, have attempted to link the impairments in learning and memory in depression with these structural abnormalities, and of those which have done so, most have included patients medicated with psychotropic agents likely to influence cognitive performance. This study thus examines the relationship between subcortical structural abnormalities and verbal memory using the California Verbal Learning Test (CVLT) in unmedicated depressed patients. A T1 weighted Magnetic Resonance Imaging scan and the CVLT were obtained on 45 subjects with major depressive disorder and 44 healthy controls. Using the FMRIB’s Integrated Registration and Segmentation Tool (FIRST) volumes of selected subcortical structures were segmented and correlated with CVLT performance. Depressed participants showed significantly smaller right thalamus and right hippocampus volumes than healthy controls. Depressed participants also showed impaired performance on global verbal learning ability, and appeared to depend upon an inferior memory strategy (serial clustering). Measures of serial clustering were correlated significantly with right hippocampal volumes in depressed participants. Our findings indicate that depressed participants and healthy controls differ in the memory strategies they employ, and that while depressed participants had a smaller hippocampal volume, there was a positive correlation between volume and use of an inferior memory strategy. This suggests that larger hippocampal volume is related to better memory recall in depression, but specifically with regard to utilizing an inferior memory strategy. PMID:22714007
SIRU utilization. Volume 1: Theory, development and test evaluation
NASA Technical Reports Server (NTRS)
Musoff, H.
1974-01-01
The theory, development, and test evaluations of the Strapdown Inertial Reference Unit (SIRU) are discussed. The statistical failure detection and isolation, single position calibration, and self alignment techniques are emphasized. Circuit diagrams of the system components are provided. Mathematical models are developed to show the performance characteristics of the subsystems. Specific areas of the utilization program are identified as: (1) error source propagation characteristics and (2) local level navigation performance demonstrations.
2014-01-01
Background The objectives of this study were to explore the relationship between olfactory impairment, cognitive measures, and brain structure volumes in healthy elderly individuals, compared to patients with amnestic mild cognitive impairment (aMCI) or early Alzheimer’s disease (AD). The primary aim was to elucidate possible differences in cognitive scores and brain structure volumes between aMCI/AD patients with relatively intact odor identification (OI) ability and those with reduced ability. Methods Twelve patients with aMCI, six with early AD, and 30 control subjects were included. OI abilities were assessed with the Brief Smell Identification Test (B-SIT) and Sniffin Sticks Identification Test (SSIT). Neuropsychological tests of executive functions and memory were performed. Brain structural volumes were obtained from T1 weighted 3D MRI at 3 Tesla. Statistical comparisons between the patients with aMCI and AD indicated no significant differences in performance on most tests. Since the groups were small and AD patients were in an early phase of disease, all patients were subsequently considered together as a single group for studying OI. Patients were subdivided into relatively intact (scores >50%) and reduced OI (≤ 50% score) on the olfactory tests. Results The aMCI/AD group with reduced OI ability, as measured by both B-SIT and SSIT, had significantly smaller hippocampal volume as compared to the patient group with OI scores > 50%. There was a significant association between OI scores and hippocampal volume in the patient (not the control) group. Similar changes with tests of executive function and memory were not found. Low OI scores on B-SIT were associated with conversion from aMCI to AD in patients. The reduced OI patient group was significantly faster on Rey complex figure copying than the fairly intact OI group. Conclusion The results from this pilot study suggest that the reduction in the size of hippocampus in connection with early AD is associated more with loss of OI ability rather than loss of memory, thus demonstrating that impaired OI is an early marker of medial temporal lobe degeneration. PMID:25154749
Method modification of the Legipid® Legionella fast detection test kit.
Albalat, Guillermo Rodríguez; Broch, Begoña Bedrina; Bono, Marisa Jiménez
2014-01-01
Legipid(®) Legionella Fast Detection is a test based on combined magnetic immunocapture and enzyme-immunoassay (CEIA) for the detection of Legionella in water. The test is based on the use of anti-Legionella antibodies immobilized on magnetic microspheres. Target microorganism is preconcentrated by filtration. Immunomagnetic analysis is applied on these preconcentrated water samples in a final test portion of 9 mL. The test kit was certified by the AOAC Research Institute as Performance Tested Method(SM) (PTM) No. 111101 in a PTM validation which certifies the performance claims of the test method in comparison to the ISO reference method 11731-1998 and the revision 11731-2004 "Water Quality: Detection and Enumeration of Legionella pneumophila" in potable water, industrial water, and waste water. The modification of this test kit has been approved. The modification includes increasing the target analyte from L. pneumophila to Legionella species and adding an optical reader to the test method. In this study, 71 strains of Legionella spp. other than L. pneumophila were tested to determine its reactivity with the kit based on CEIA. All the strains of Legionella spp. tested by the CEIA test were confirmed positive by reference standard method ISO 11731. This test (PTM 111101) has been modified to include a final optical reading. A methods comparison study was conducted to demonstrate the equivalence of this modification to the reference culture method. Two water matrixes were analyzed. Results show no statistically detectable difference between the test method and the reference culture method for the enumeration of Legionella spp. The relative level of detection was 93 CFU/volume examined (LOD50). For optical reading, the LOD was 40 CFU/volume examined and the LOQ was 60 CFU/volume examined. Results showed that the test Legipid Legionella Fast Detection is equivalent to the reference culture method for the enumeration of Legionella spp.
The report gives results of a study in which NOx emissions and general combustion performance characteristics of four burners were evaluated under experimental furnace conditions. Of primary interest was the performance of a low NOx Distributed Mixing Burner (DMB), which was test...
DOT National Transportation Integrated Search
1976-09-01
Results of performance evaluation of voice, digital data and ranging modems in the aeronautical satellite environment are given. Approximately 80 hours of modem performance data were acquired on board an FAA KC-135 jet aircraft operating over the Nor...
Project fires. Volume 2: Protective ensemble performance standards, phase 1B
NASA Astrophysics Data System (ADS)
Abeles, F. J.
1980-05-01
The design of the prototype protective ensemble was finalized. Prototype ensembles were fabricated and then subjected to a series of qualification tests which were based upon the protective ensemble performance standards PEPS requirements. Engineering drawings and purchase specifications were prepared for the new protective ensemble.
21 CFR 868.1840 - Diagnostic spirometer.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) Identification. A diagnostic spirometer is a device used in pulmonary function testing to measure the volume of gas moving in or out of a patient's lungs. (b) Classification. Class II (performance standards). ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steve Hoeffner
2003-12-31
The Clemson Environmental Technologies Laboratory (CETL) was contracted by the National Energy Technology Center to evaluate technologies that might be used to reduce the volume of plutonium-contaminated soil at the Nevada Test Site. The project has been systematically approached. A thorough review and summary was completed for: (1) The NTS soil geological, geochemical and physical characteristics; (2) The characteristics and chemical form of the plutonium that is in these soils; (3) Previous volume reduction technologies that have been attempted on the NTS soils; (4) Vendors with technology that may be applicable; and (5) Related needs at other DOE sites. Soilsmore » from the Nevada Test Site were collected and delivered to the CETL. Soils were characterized for Pu-239/240, Am-241 and gross alpha. In addition, wet sieving and the subsequent characterization were performed on soils before and after attrition scrubbing to determine the particle size distribution and the distribution of Pu-239/240 and gross alpha as a function of particle size. Sequential extraction was performed on untreated soil to provide information about how tightly bound the plutonium was to the soil. Magnetic separation was performed to determine if this could be useful as part of a treatment approach. Using the information obtained from these reviews, three vendors were selected to demonstration their volume reduction technologies at the CETL. Two of the three technologies, bioremediation and soil washing, met the performance criteria. Both were able to significantly reduce the concentration plutonium in the soil from around 1100 pCi/g to 200 pCi/g or less with a volume reduction of around 95%, well over the target 70%. These results are especially encouraging because they indicate significant improvement over that obtained in these earlier pilot and field studies. Additional studies are recommended.« less
ERIC Educational Resources Information Center
Thompson, Barbara; Baumann, Paul
2011-01-01
Whether referred to as "pay-for-performance" (PFP) or "merit pay," attempting to tie educators' compensation to their performance in the classroom and students' performance on high-stakes tests has been a key component of many educator compensation reform efforts in the last five years. This issue looks at PFP systems broadly…
Systems design study of the Pioneer Venus spacecraft. Volume 2. Preliminary program development plan
NASA Technical Reports Server (NTRS)
1973-01-01
The preliminary development plan for the Pioneer Venus program is presented. This preliminary plan treats only developmental aspects that would have a significant effect on program cost. These significant development areas were: master program schedule planning; test planning - both unit and system testing for probes/orbiter/ probe bus; ground support equipment; performance assurance; and science integration Various test planning options and test method techniques were evaluated in terms of achieving a low-cost program without degrading mission performance or system reliability. The approaches studied and the methodology of the selected approach are defined.
DOE Office of Scientific and Technical Information (OSTI.GOV)
REICH, F.R.
The PHMC will provide Low Activity Wastes (LAW) tank wastes for final treatment by a privatization contractor from two double-shell feed tanks, 241-AP-102 and 241-AP-104. Concerns about the inability of the baseline ''grab'' sampling to provide large volume samples within time constraints has led to the development of a nested, fixed-depth sampling system. This sampling system will provide large volume, representative samples without the environmental, radiation exposure, and sample volume impacts of the current base-line ''grab'' sampling method. A plan has been developed for the cold testing of this nested, fixed-depth sampling system with simulant materials. The sampling system willmore » fill the 500-ml bottles and provide inner packaging to interface with the Hanford Sites cask shipping systems (PAS-1 and/or ''safe-send''). The sampling system will provide a waste stream that will be used for on-line, real-time measurements with an at-tank analysis system. The cold tests evaluate the performance and ability to provide samples that are representative of the tanks' content within a 95 percent confidence interval, to sample while mixing pumps are operating, to provide large sample volumes (1-15 liters) within a short time interval, to sample supernatant wastes with over 25 wt% solids content, to recover from precipitation- and settling-based plugging, and the potential to operate over the 20-year expected time span of the privatization contract.« less
Nathan, Pradeep J; Lim, Yen Ying; Abbott, Rosemary; Galluzzi, Samantha; Marizzoni, Moira; Babiloni, Claudio; Albani, Diego; Bartres-Faz, David; Didic, Mira; Farotti, Lucia; Parnetti, Lucilla; Salvadori, Nicola; Müller, Bernhard W; Forloni, Gianluigi; Girtler, Nicola; Hensch, Tilman; Jovicich, Jorge; Leeuwis, Annebet; Marra, Camillo; Molinuevo, José Luis; Nobili, Flavio; Pariente, Jeremie; Payoux, Pierre; Ranjeva, Jean-Philippe; Rolandi, Elena; Rossini, Paolo Maria; Schönknecht, Peter; Soricelli, Andrea; Tsolaki, Magda; Visser, Pieter Jelle; Wiltfang, Jens; Richardson, Jill C; Bordet, Régis; Blin, Olivier; Frisoni, Giovanni B
2017-05-01
Few studies have examined the relationship between CSF and structural biomarkers, and cognitive function in MCI. We examined the relationship between cognitive function, hippocampal volume and cerebrospinal fluid (CSF) Aβ 42 and tau in 145 patients with MCI. Patients were assessed on cognitive tasks from the Cambridge Neuropsychological Test Automated Battery (CANTAB), the Geriatric Depression Scale and the Functional Activities Questionnaire. Hippocampal volume was measured using magnetic resonance imaging (MRI), and CSF markers of Aβ 42 , tau and p-tau 181 were also measured. Worse performance on a wide range of memory and sustained attention tasks were associated with reduced hippocampal volume, higher CSF tau and p-tau 181 and increased tau/Aβ 42 ratio. Memory tasks were also associated with lower ability to conduct functional activities of daily living, providing a link between AD biomarkers, memory performance and functional outcome. These results suggest that biomarkers of Aβ and tau are strongly related to cognitive performance as assessed by the CANTAB, and have implications for the early detection and characterization of incipient AD. Copyright © 2017 Elsevier Inc. All rights reserved.
Materials Science Research Rack-1 Fire Suppressant Distribution Test Report
NASA Technical Reports Server (NTRS)
Wieland, P. O.
2002-01-01
Fire suppressant distribution testing was performed on the Materials Science Research Rack-1 (MSRR-1), a furnace facility payload that will be installed in the U.S. Lab module of the International Space Station. Unlike racks that were tested previously, the MSRR-1 uses the Active Rack Isolation System (ARIS) to reduce vibration on experiments, so the effects of ARIS on fire suppressant distribution were unknown. Two tests were performed to map the distribution of CO2 fire suppressant throughout a mockup of the MSRR-1 designed to have the same component volumes and flowpath restrictions as the flight rack. For the first test, the average maximum CO2 concentration for the rack was 60 percent, achieved within 45 s of discharge initiation, meeting the requirement to reach 50 percent throughout the rack within 1 min. For the second test, one of the experiment mockups was removed to provide a worst-case configuration, and the average maximum CO2 concentration for the rack was 58 percent. Comparing the results of this testing with results from previous testing leads to several general conclusions that can be used to evaluate future racks. The MSRR-1 will meet the requirements for fire suppressant distribution. Primary factors that affect the ability to meet the CO2 distribution requirements are the free air volume in the rack and the total area and distribution of openings in the rack shell. The length of the suppressant flowpath and degree of tortuousness has little correlation with CO2 concentration. The total area of holes in the rack shell could be significantly increased. The free air volume could be significantly increased. To ensure the highest maximum CO2 concentration, the PFE nozzle should be inserted to the stop on the nozzle.
Slow crack growth test method for polyethylene gas pipes. Volume 1. Topical report, December 1992
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leis, B.; Ahmad, J.; Forte, T.
1992-12-01
In spite of the excellent performance record of polyethylene (PE) pipes used for gas distribution, a small number of leaks occur in distribution systems each year because of slow growth of cracks through pipe walls. The Slow Crack Growth Test (SCG) has been developed as a key element in a methodology for the assessment of the performance of polyethylene gas distribution systems to resist such leaks. This tropical report describes work conducted in the first part of the research directed at the initial development of the SCG test, including a critical evaluation of the applicability of the SCG test asmore » an element in PE gas pipe system performance methodology. Results of extensive experiments and analysis are reported. The results show that the SCG test should be very useful in performance assessment.« less
Validation of Modifications to the ANSR(®) Listeria Method for Improved Ease of Use and Performance.
Caballero, Oscar; Alles, Susan; Le, Quynh-Nhi; Gray, R Lucas; Hosking, Edan; Pinkava, Lisa; Norton, Paul; Tolan, Jerry; Mozola, Mark; Rice, Jennifer; Chen, Yi; Odumeru, Joseph; Ryser, Elliot
2016-01-01
A study was conducted to validate minor reagent formulation, enrichment, and procedural changes to the ANSR(®) Listeria method, Performance-Tested Method(SM) 101202. In order to improve ease of use and diminish risk of amplicon contamination, the lyophilized reagent components were reformulated for increased solubility, thus eliminating the need to mix by pipetting. In the alternative procedure, an aliquot of the lysate is added to lyophilized ANSR reagents, immediately capped, and briefly mixed by vortexing. When three foods (hot dogs, Mexican-style cheese, and cantaloupe) and sponge samples taken from a stainless steel surface were tested, significant differences in performance between the ANSR and U.S. Food and Drug Administration Bacteriological Analytical Manual or U.S. Department of Agriculture, Food Safety and Inspection Service Microbiology Laboratory Guidebook reference culture procedures were seen with hot dogs and Mexican-style cheese after 16 h enrichment, with the reference methods producing more positive results. After 24 h enrichment, however, there were no significant differences in method performance for any of the four matrixes tested. Robustness testing was also conducted, with variations to lysis buffer volume, lysis time, and sample volume having no demonstrable effect on assay results. Accelerated stability testing was carried out over a 10-week period and showed no diminishment in assay performance. A second phase of the study examined performance of the ANSR assay following enrichment in a new medium, LESS Plus broth, designed for use with all food and environmental sample types. With the alternative LESS Plus broth, there were no significant differences in performance between the ANSR method and the reference culture procedures for any of the matrixes tested after either 16 or 24 h enrichment, although 24 h enrichment is recommended for hot dogs due to higher sensitivity. Results of inclusivity and exclusivity testing using LESS Plus broth showed that the ANSR assay is highly specific, with 100% expected results for target and nontarget bacteria.
Wang, He; Lu, Shi-Chun; He, Lei; Dong, Jia-Hong
2018-02-01
Liver failure remains as the most common complication and cause of death after hepatectomy, and continues to be a challenge for doctors.t test and χ test were used for single factor analysis of data-related variables, then results were introduced into the model to undergo the multiple factors logistic regression analysis. Pearson correlation analysis was performed for related postoperative indexes, and a diagnostic evaluation was performed using the receiver operating characteristic (ROC) of postoperative indexes.Differences in age, body mass index (BMI), portal vein hypertension, bile duct cancer, total bilirubin, alkaline phosphatase (ALP), gamma-glutamyl transpeptidase (GGT), operation time, cumulative portal vein occlusion time, intraoperative blood volume, residual liver volume (RLV)/entire live rvolume, ascites volume at postoperative day (POD)3, supplemental albumin amount at POD3, hospitalization time after operation, and the prothrombin activity (PTA) were statistically significant. Furthermore, there were significant differences in total bilirubin and the supplemental albumin amount at POD3. ROC analysis of the average PTA, albumin amounts, ascites volume at POD3, and their combined diagnosis were performed, which had diagnostic value for postoperative liver failure (area under the curve (AUC): 0.895, AUC: 0.798, AUC: 0.775, and AUC: 0.903).Preoperative total bilirubin level and the supplemental albumin amount at POD3 were independent risk factors. PTA can be used as the index of postoperative liver failure, and the combined diagnosis of the indexes can improve the early prediction of postoperative liver failure.
van den Boer, Cindy; Muller, Sara H; Vincent, Andrew D; van den Brekel, Michiel W M; Hilgers, Frans J M
2014-08-01
Breathing through a tracheostoma results in insufficient warming and humidification of the inspired air. This loss of air conditioning, especially humidification, can be partially restored with the application of a heat and moisture exchanger (HME) over the tracheostoma. For medical professionals, it is not easy to judge differences in water exchange performance of various HMEs owing to the lack of universal outcome measures. This study has three aims: assessment of the water exchange performance of commercially available HMEs for laryngectomized patients, validation of these results with absolute humidity outcomes, and assessment of the role of hygroscopic salt present in some of the tested HMEs. Measurements of weight and absolute humidity at end inspiration and end expiration at different breathing volumes of a healthy volunteer were performed using a microbalance and humidity sensor. Twenty-three HMEs from 6 different manufacturers were tested. Associations were determined between core weight, weight change, breathing volume, and absolute humidity, using both linear and nonlinear mixed effects models. Water exchange of the 23 HMEs at a breathing volume of 0.5 L varies between 0.5 and 3.6 mg. Both water exchange and wet core weight correlate strongly with the end-inspiratory absolute humidity values (r2 =0.89/0.87). Hygroscopic salt increases core weight. The 23 tested HMEs for laryngectomized patients show wide variation in water exchange performance. Water exchange correlates well with the end-inspiratory absolute humidity outcome, which validates the ex vivo weight change method. Wet core weight is a predictor of HME performance. Hygroscopic salt increases the weight of the core material. The results of this study can help medical professionals to obtain a more founded opinion about the performance of available HMEs for pulmonary rehabilitation in laryngectomized patients, and allow them to make an informed decision about which HME type to use.
NASA Technical Reports Server (NTRS)
Hruby, R. J.; Bjorkman, W. S.
1977-01-01
Flight test results of the strapdown inertial reference unit (SIRU) navigation system are presented. The fault-tolerant SIRU navigation system features a redundant inertial sensor unit and dual computers. System software provides for detection and isolation of inertial sensor failures and continued operation in the event of failures. Flight test results include assessments of the system's navigational performance and fault tolerance.
Project FIRES. Volume 1: Program Overview and Summary, Phase 1B
NASA Technical Reports Server (NTRS)
Abeles, F. J.
1980-01-01
Overall performance requirements and evaluation methods for firefighters protective equipment were established and published as the Protective Ensemble Performance Standards (PEPS). Current firefighters protective equipment was tested and evaluated against the PEPS requirements, and the preliminary design of a prototype protective ensemble was performed. In phase 1B, the design of the prototype ensemble was finalized. Prototype ensembles were fabricated and then subjected to a series of qualification tests which were based upon the PEPS requirements. Engineering drawings and purchase specifications were prepared for the new protective ensemble.
NASA Technical Reports Server (NTRS)
Kleckner, R. J.; Rosenlieb, J. W.; Dyba, G.
1980-01-01
The results of a series of full scale hardware tests comparing predictions of the SPHERBEAN computer program with measured data are presented. The SPHERBEAN program predicts the thermomechanical performance characteristics of high speed lubricated double row spherical roller bearings. The degree of correlation between performance predicted by SPHERBEAN and measured data is demonstrated. Experimental and calculated performance data is compared over a range in speed up to 19,400 rpm (0.8 MDN) under pure radial, pure axial, and combined loads.
[Experience of a Break-Even Point Analysis for Make-or-Buy Decision.].
Kim, Yunhee
2006-12-01
Cost containment through continuous quality improvement of medical service is required in an age of a keen competition of the medical market. Laboratory managers should examine the matters on make-or-buy decision periodically. On this occasion, a break-even point analysis can be useful as an analyzing tool. In this study, cost accounting and break-even point (BEP) analysis were performed in case that the immunoassay items showing a recent increase in order volume were to be in-house made. Fixed and variable costs were calculated in case that alpha fetoprotein (AFP), carcinoembryonic antigen (CEA), prostate-specific antigen (PSA), ferritin, free thyroxine (fT4), triiodothyronine (T3), thyroid-stimulating hormone (TSH), CA 125, CA 19-9, and hepatitis B envelope antibody (HBeAb) were to be tested with Abbott AxSYM instrument. Break-even volume was calculated as fixed cost per year divided by purchasing cost per test minus variable cost per test and BEP ratio as total purchasing costs at break-even volume divided by total purchasing costs at actual annual volume. The average fixed cost per year of AFP, CEA, PSA, ferritin, fT4, T3, TSH, CA 125, CA 19-9, and HBeAb was 8,279,187 won and average variable cost per test, 3,786 won. Average break-even volume was 1,599 and average BEP ratio was 852%. Average BEP ratio without including quality costs such as calibration and quality control was 74%. Because the quality assurance of clinical tests cannot be waived, outsourcing all of 10 items was more adequate than in-house make at the present volume in financial aspect. BEP analysis was useful as a financial tool for make-or-buy decision, the common matter which laboratory managers meet with.
NASA Technical Reports Server (NTRS)
1979-01-01
The results of the Coastal Zone Color Scanner protoflight tests are examined in detail while some of the test results are evaluated with respect to expected performance. Performance characteristics examined include spectral response, signal to noise ratio as a function of radiance input, radiance response, the modulation transfer function, and the field of view and coregistration. The results of orbital sequence tests are also included. The in orbit performance or return of radiometric data in the six spectral bands is evaluated along with the data processing sequence necessary to derive the final data products. Examples of the raw data are given and the housekeeping or diagnostic data which provides information on the day to day health or status of the instrument are discussed.
Neuroanatomical Correlates of Intelligence in Healthy Young Adults: The Role of Basal Ganglia Volume
Rhein, Cosima; Mühle, Christiane; Richter-Schmidinger, Tanja; Alexopoulos, Panagiotis; Doerfler, Arnd; Kornhuber, Johannes
2014-01-01
Background In neuropsychiatric diseases with basal ganglia involvement, higher cognitive functions are often impaired. In this exploratory study, we examined healthy young adults to gain detailed insight into the relationship between basal ganglia volume and cognitive abilities under non-pathological conditions. Methodology/Principal Findings We investigated 137 healthy adults that were between the ages of 21 and 35 years with similar educational backgrounds. Magnetic resonance imaging (MRI) was performed, and volumes of basal ganglia nuclei in both hemispheres were calculated using FreeSurfer software. The cognitive assessment consisted of verbal, numeric and figural aspects of intelligence for either the fluid or the crystallised intelligence factor using the intelligence test Intelligenz-Struktur-Test (I-S-T 2000 R). Our data revealed significant correlations of the caudate nucleus and pallidum volumes with figural and numeric aspects of intelligence, but not with verbal intelligence. Interestingly, figural intelligence associations were dependent on sex and intelligence factor; in females, the pallidum volumes were correlated with crystallised figural intelligence (r = 0.372, p = 0.01), whereas in males, the caudate volumes were correlated with fluid figural intelligence (r = 0.507, p = 0.01). Numeric intelligence was correlated with right-lateralised caudate nucleus volumes for both females and males, but only for crystallised intelligence (r = 0.306, p = 0.04 and r = 0.459, p = 0.04, respectively). The associations were not mediated by prefrontal cortical subfield volumes when controlling with partial correlation analyses. Conclusions/Significance The findings of our exploratory analysis indicate that figural and numeric intelligence aspects, but not verbal aspects, are strongly associated with basal ganglia volumes. Unlike numeric intelligence, the type of figural intelligence appears to be related to distinct basal ganglia nuclei in a sex-specific manner. Subcortical brain structures thus may contribute substantially to cognitive performance. PMID:24699871
Abdelsattar, Jad M; AlJamal, Yazan N; Ruparel, Raaj K; Rowse, Phillip G; Heller, Stephanie F; Farley, David R
2018-05-14
Faculty evaluations, ABSITE scores, and operative case volumes often tell little about true resident performance. We developed an objective structured clinical examination called the Surgical X-Games (5 rooms, 15 minutes each, 12-15 tests total, different for each postgraduate [PGY] level). We hypothesized that performance in X-Games will prove more useful in identifying areas of strength or weakness among general surgery (GS) residents than faculty evaluations, ABSITE scores, or operative cases volumes. PGY 2 to 5 GS residents (n = 35) were tested in a semiannual X-Games assessment using multiple simulation tasks: laparoscopic skills, bowel anastomosis, CT/CXR analysis, chest tube placement, etc. over 1 academic year. Resident scores were compared to their ABSITE, in-training evaluation reports, and operating room case numbers. Academic medical center. PGY-2, 3, 4, and 5 GS residents at Mayo Clinic in Rochester, MN. Results varied greatly within each class except for staff evaluations: in-training evaluation reports medians for PGY-2s were 5.3 (range: 5.0-6.0), PGY-3s 5.9 (5.5-6.3), PGY-4s 5.6 (5.0-6.0), and PGY-5s were 6.1 (5.6-6.9). Although ABSITE and operating room case volumes fluctated greatly with each PGY class, only X-Games scores (median: PGY-2 = 82, PGY-3 = 61, PGY-4 = 76, and PGY-5 = 60) correlated positively (p < 0.05) with operative case volume and negatively (p < 0.05) with staff evaluations. X-Games assessment generated wide differentiation of resident performance quickly, inexpensively, and objectively. Although "Minnesota-nice" surgical staff may feel all GS trainees are "above average," objective assessment tells us otherwise. Copyright © 2018 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1994-07-01
The 1994 Symposium on Valve and Pump Testing, jointly sponsored by the Board of Nuclear Codes and Standards of the American Society of Mechanical Engineers and by the Nuclear Regulatory Commission, provides a forum for the discussion of current programs and methods for inservice testing and motor-operated valve testing at nuclear power plants. The symposium also provides an opportunity to discuss the need to improve that testing in order to help ensure the reliable performance of pumps and valves. The participation of industry representatives, regulators, and consultants results in the discussion of a broad spectrum of ideas and perspectives regardingmore » the improvement of inservice testing of pumps and valves at nuclear power plants. This document, Volume 1, covers sessions 1A through session 2C. The individual papers have been cataloged separately.« less
Trontel, Haley G.; Duffield, Tyler C.; Bigler, Erin D.; Abildskov, Tracy J.; Froehlich, Alyson; Prigge, Molly B.D.; Travers, Brittany G.; Anderson, Jeffrey S.; Zielinski, Brandon A.; Alexander, Andrew; Lange, Nicholas; Lainhart, Janet E.
2015-01-01
Studies have shown that individuals with autism spectrum disorder (ASD) tend to perform significantly below typical developing individuals on standardized measures of memory, even when not significantly different on measures of IQ. The current study sought to examine within ASD whether anatomical correlates of memory performance differed between those with average-to-above-average IQ (AIQ Group) compared to those with low average to borderline ability (LIQ group) as well as in relations to typically-developing comparisons (TDC). Using automated volumetric analyses, we examined regional volume of classic memory areas including the hippocampus, parahippocampal gyrus, entorhinal cortex, and amygdala in an all-male sample AIQ (n = 38) and LIQ (n = 18) individuals with ASD along with 30 typically-developing comparisons (TDC). Memory performance was assessed using the Test of Memory and Learning (TOMAL) compared among the groups and then correlated with regional brain volumes. Analyses revealed group differences on almost all facets of memory and learning as assessed by the various subtests of the TOMAL. The three groups did not differ on any ROI memory-related brain volumes. However, significant size-memory function interactions were observed. Negative correlations were found between the volume of the amygdala and composite, verbal, and delayed memory indices for the LIQ ASD group indicating larger volume related to poorer performance. Implications for general memory functioning and dysfunctional neural connectivity in ASD are discussed. PMID:25749302
Compressive evaluation of homogeneous and graded epoxy-glass particulate composites.
Seaglar, J; Rousseau, C-E
2015-04-01
The propagation of stress waves in epoxy-glass particulate composites and graded materials was studied experimentally. Materials tested in this study consisted of an epoxy matrix with various concentrations of spherical glass particles having a mean diameter of 42μm. Plate impact experiments were performed using a gas gun. Embedded within the specimens were manganin stress gauges used to record propagating compressive longitudinal stress waves through the material. High strain rate experiments using a Split Hopkinson Pressure Bar (SHPB) apparatus were also performed to evaluate the dynamic strength of the specimens, while quasi-static compression tests were undertaken to characterize their quasi-static behavior. Ultrasonic wave speed measurements were carried-out in order to obtain additional material properties and characterize the gradation in functionally graded materials (FGM). It was found that low volume fractions of particles are detrimental to the performance of the material under impact loading, while concentrations in the range of about 30 to 45% by volume exhibit characteristics of higher degrees of scattering. This suggests that materials in this latter range would be more effective in the thwarting of destructive shock waves than the homogeneous matrix material. Impact testing of FGM specimens suggests that impact loading on the stiff (high volume fraction) face results in much higher levels of scattering. Therefore, such materials would be effective for use in light weight armor or as shielding materials due to their effective attenuation of mechanical impulses. Copyright © 2015 Elsevier B.V. All rights reserved.
Classification of SD-OCT volumes for DME detection: an anomaly detection approach
NASA Astrophysics Data System (ADS)
Sankar, S.; Sidibé, D.; Cheung, Y.; Wong, T. Y.; Lamoureux, E.; Milea, D.; Meriaudeau, F.
2016-03-01
Diabetic Macular Edema (DME) is the leading cause of blindness amongst diabetic patients worldwide. It is characterized by accumulation of water molecules in the macula leading to swelling. Early detection of the disease helps prevent further loss of vision. Naturally, automated detection of DME from Optical Coherence Tomography (OCT) volumes plays a key role. To this end, a pipeline for detecting DME diseases in OCT volumes is proposed in this paper. The method is based on anomaly detection using Gaussian Mixture Model (GMM). It starts with pre-processing the B-scans by resizing, flattening, filtering and extracting features from them. Both intensity and Local Binary Pattern (LBP) features are considered. The dimensionality of the extracted features is reduced using PCA. As the last stage, a GMM is fitted with features from normal volumes. During testing, features extracted from the test volume are evaluated with the fitted model for anomaly and classification is made based on the number of B-scans detected as outliers. The proposed method is tested on two OCT datasets achieving a sensitivity and a specificity of 80% and 93% on the first dataset, and 100% and 80% on the second one. Moreover, experiments show that the proposed method achieves better classification performances than other recently published works.
NASA Technical Reports Server (NTRS)
1977-01-01
Results of initial tests of the under the wing experimental engine and boilerplate nacelle are presented. The mechanical performance of the engine is reported with emphasis on the advanced technology components. Technology elements of the propulsion system covered include: system dynamics, composite fan blades, reduction gear, lube and accessory drive system, fan frame, inlet, core cowl cooling, fan exhaust nozzle, and digital control system.
Spacesuit Water Membrane Evaporator Development for Lunar Missions
NASA Technical Reports Server (NTRS)
Vogel, Matt R.; Peterson, Keith; Zapata, Felipe, III; Dillon, Paul; Trevino, Luis A.
2008-01-01
For future lunar extra-vehicular activities (EVA), one method under consideration for rejecting crew and electronics heat involves evaporating water through a hydrophobic, porous Teflon membrane. A Spacesuit Water Membrane Evaporator (SWME) prototype using the Teflon membrane was tested successfully by Ungar and Thomas (2001) with predicted performance matching test data well. The above referenced work laid the foundation for the design of the SWME development unit, which is being considered for service in the Constellation System Spacesuit Element (CSSE) Portable Life Support System (PLSS). Multiple PLSS SWME configurations were considered on the basis of thermal performance, mass, volume, and performance and manufacturing risk. All configurations were a variation of an alternating concentric water and vapor channel configuration or a stack of alternating rectangular water and vapor channels. Supporting thermal performance trades mapped maximum SWME heat rejection as a function of water channel thickness, vapor channel thickness, channel length, number of water channels, porosity of the membrane structural support, and backpressure valve throat area. Preliminary designs of each configuration were developed to determine total mass and volume as well as to understand manufacturing issues. Review of configurations led to the selection of a concentric annulus configuration that meets the requirements of 800 watts (W) of heat rejection. Detailed design of the SWME development unit will be followed by fabrication of a prototype test unit, with thermal testing expected to start in 2008.
Sterr, Annette; Dean, Phil J A; Szameitat, Andre J; Conforto, Adriana Bastos; Shen, Shan
2014-05-01
Initial evidence suggests that the integrity of the ipsilesional corticospinal tract (CST) after stroke is strongly related to motor function in the chronic state but not the treatment gain induced by motor rehabilitation. We examined the association of motor status and treatment benefit by testing patients with a wide range of severity of hemiparesis of the left and right upper extremity. Diffusion tensor imaging was performed in 22 patients beyond 12 months after onset of stroke with severe to moderate hemiparesis. Motor function was tested before and after 2 weeks of modified constraint-induced movement therapy. CST integrity, but not lesion volume, correlated with the motor ability measures of the Wolf Motor Function Test and the Motor Activity Log. No differences were found between left and right hemiparesis. Motor performance improved significantly with the treatment regime, and did so equally for patients with left and right arm paresis. However, treatment benefit was not associated with either CST integrity or lesion volume. CST integrity correlated best in this small trial with chronic long-term status but not treatment-induced improvements. The CST may play a different role in the mechanisms mediating long-term outcome compared to those underlying practice-induced gains after a chronic plateau in motor function.
DOT National Transportation Integrated Search
1979-02-01
The SLRV (Standard Light Rail Vehicle) is a 71-foot vehicle, articulated to negotiate curves down to a 32-foot radius and designed to operate at speeds up to 50 mph. Although the basic configuration and performance is standardized, the current operat...
DOT National Transportation Integrated Search
2001-01-01
This report documents the results of backcalculation of layer material properties for rigid pavements included in the Long Term Pavement Performance (LTPP) program in the United States and Canada using deflection testing data. This study backcalculat...
DOT National Transportation Integrated Search
1976-09-01
Aircraft L-band antennas designed for satellite communication were evaluated using an FAA KC-135 aircraft and the NASA ATS-6 satellite. All tests were performed between September 1974 and April 1975 as one component of the U.S. DOT/FAA aeronautical t...
DOT National Transportation Integrated Search
2001-01-01
This report documents the results of backcalculation of layer material properties for rigid pavements included in the Long Term Pavement Performance (LTPP) program in the United States and Canada using deflection testing data. This study backcalculat...
Tribological Technology. Volume II.
1982-09-01
rolling bearings, gears, and sliding bearings produce distinctive particles. An atlas of such particles is available2 9 . Atlases of characteristic...Gravitational methods cover both sedimentation and elutration techniques. Inertial type separators perform cyclonic classification. Ferrography is the...generated after each size exposure of contaminant. This can be done today using Ferrography . Standard contaminant sensitivity tests require test
Acoustic Treatment Design Scaling Methods. Volume 5; Analytical and Experimental Data Correlation
NASA Technical Reports Server (NTRS)
Chien, W. E.; Kraft, R. E.; Syed, A. A.
1999-01-01
The primary purpose of the study presented in this volume is to present the results and data analysis of in-duct transmission loss measurements. Transmission loss testing was performed on full-scale, 1/2-scale, and 115-scale treatment panel samples. The objective of the study was to compare predicted and measured transmission loss for full-scale and subscale panels in an attempt to evaluate the variations in suppression between full- and subscale panels which were ostensibly of equivalent design. Generally, the results indicated an unsatisfactory agreement between measurement and prediction, even for full-scale. This was attributable to difficulties encountered in obtaining sufficiently accurate test results, even with extraordinary care in calibrating the instrumentation and performing the test. Test difficulties precluded the ability to make measurements at frequencies high enough to be representative of subscale liners. It is concluded that transmission loss measurements without ducts and data acquisition facilities specifically designed to operate with the precision and complexity required for high subscale frequency ranges are inadequate for evaluation of subscale treatment effects.
The Effects of Using Space to Teach Standard Elementary School Curriculum
NASA Technical Reports Server (NTRS)
Ewell, Robert N.
1996-01-01
This brief report and recommendation for further research brings to a formal close this effort, the original purpose of which is described in detail in The effects of using space to teach standard elementary school curriculum, Volume 1, included here as the Appendix. Volume 1 describes the project as a 3-year research program to determine the effectiveness of using space to teach. The research design is quasi experimental using standardized test data on students from Aldrin Elementary School and a District-identified 'control' school, which shall be referred to as 'School B.' Students now in fourth through sixth grades will be compared now (after one year at Aldrin) and tracked at least until the present sixth graders are through the eighth grade. Appropriate statistical tests will be applied to standardized test scores to see if Aldrin students are 'better' than School B students in areas such as: Overall academic performance; Performance in math/science; and Enrollments in math/science in middle school.
Manoharan, Sujatha C; Ramakrishnan, Swaminathan
2009-10-01
In this work, prediction of forced expiratory volume in pulmonary function test, carried out using spirometry and neural networks is presented. The pulmonary function data were recorded from volunteers using commercial available flow volume spirometer in standard acquisition protocol. The Radial Basis Function neural networks were used to predict forced expiratory volume in 1 s (FEV1) from the recorded flow volume curves. The optimal centres of the hidden layer of radial basis function were determined by k-means clustering algorithm. The performance of the neural network model was evaluated by computing their prediction error statistics of average value, standard deviation, root mean square and their correlation with the true data for normal, restrictive and obstructive cases. Results show that the adopted neural networks are capable of predicting FEV1 in both normal and abnormal cases. Prediction accuracy was more in obstructive abnormality when compared to restrictive cases. It appears that this method of assessment is useful in diagnosing the pulmonary abnormalities with incomplete data and data with poor recording.
Hamamoto, Shinichi; Okuma, Tomohisa; Yamamoto, Akira; Kageyama, Ken; Takeshita, Toru; Sakai, Yukimasa; Nishida, Norifumi; Matsuoka, Toshiyuki; Miki, Yukio
2013-05-01
To evaluate whether antitumor immunity is enhanced systemically by combining radiofrequency ablation (RFA) and local injection of an immunostimulant, OK-432. Experiments were approved by the institutional animal care committee. Experimental Japanese rabbits inoculated with VX2 tumors in the lung and the auricle were randomized into four groups of eight: control (supportive care), RFA (RFA of lung tumor), OK-432 (direct injection of OK-432 into lung tumor), and combination therapy (lung RFA and direct OK-432 injection into lung tumor). All procedures were performed 1 week after implantation of VX2 tumors (week 1). In addition, a VX2 tumor rechallenge test was performed in the RFA and combination therapy groups. Survival time was evaluated by means of the Kaplan-Meier method and by using the log-rank test for intergroup comparison. Mean auricle tumor volumes were calculated every week. Specific growth rates (SGRs) were calculated and compared by using the Mann-Whitney test. The median survival times of the control, RFA, OK-432, and combination therapy groups were 23, 36.5, 46.5, and 105 days, respectively. Survival was significantly prolonged in the combination therapy group when compared with the other three groups (P <.05). The mean auricle tumor volume decreased only in the combination therapy group. The mean auricle tumor volumes of the combination therapy group from week 1 to week 7 were 205, 339, 264, 227, 143, 127, and 115 mm(3). SGR in the combination therapy group became significantly smaller than those in the other three groups (P < .05). In the rechallenge test, the volume of all reimplanted tumors decreased. Combining RFA with local injection of immunostimulant OK-432 may lead to indirectly activation of systemic antitumor immunity. © RSNA, 2013.
van Putten, Erik H P; Wembacher-Schröder, Eva; Smits, Marion; Dirven, Clemens M F
2016-05-01
In a phase 1 trial conducted at our institute, convection-enhanced delivery (CED) was used to administrate the Delta-24-RGD adenovirus in patients with a recurrent glioblastoma multiforme. Infusion of the virus was preceded by a gadolinium-conjugated diethylenetriamine penta-acetic acid (Gd-DTPA) test-infusion. In the present study, we analyzed the results of Gd-DTPA test infusion through 50 catheters. Thirteen adults with a recurrent glioblastoma multiforme were enrolled in a larger phase 1 multicenter, dose-finding study, in which a conditionally replication-competent adenovirus was administered by CED. Up to 4 infusion catheters per patient were placed intra- and/or peritumorally. Before infusion of the virus, a Gd-DTPA infusion was performed for 6 hours, directly followed by a MRI scan. The MRIs were evaluated for catheter position, Gd-DTPA distribution outcome, and contrast leakage. Leakage of Gd-DTPA into the cerebrospinal fluid was detected in 17 of the 50 catheters (34%). Sulcus crossing was the most frequent cause of leakage. In 8 cases, leakage could only be detected on the fluid-attenuated inversion recovery sequence. Nonleaking catheters showed a significantly larger Gd-DTPA distribution fraction (volume of distribution/volume of infusion) than leaking catheters (P = 0.009). A significantly lower volume of distribution/volume of infusion was observed in intratumoral catheters, compared with peritumoral catheters (P = 0.004). Gd-DTPA test infusion did not result in significant changes in Karnofsky Performance Score and Neurological Status. Pre-CED treatment infusion of Gd-DTPA is an adequate and safe method to identify dysfunctional catheters. The use of an optimized drug delivery catheter is necessary to reduce leakage and improve the efficacy of intracerebral drug infusion. Copyright © 2016 Elsevier Inc. All rights reserved.
Müller-Oehring, Eva M; Schulte, Tilman; Rohlfing, Torsten; Pfefferbaum, Adolf; Sullivan, Edith V
2013-01-01
Decline in visuospatial abilities with advancing age has been attributed to a demise of bottom-up and top-down functions involving sensory processing, selective attention, and executive control. These functions may be differentially affected by age-related volume shrinkage of subcortical and cortical nodes subserving the dorsal and ventral processing streams and the corpus callosum mediating interhemispheric information exchange. Fifty-five healthy adults (25-84 years) underwent structural MRI and performed a visual search task to test perceptual and attentional demands by combining feature-conjunction searches with "gestalt" grouping and attentional cueing paradigms. Poorer conjunction, but not feature, search performance was related to older age and volume shrinkage of nodes in the dorsolateral processing stream. When displays allowed perceptual grouping through distractor homogeneity, poorer conjunction-search performance correlated with smaller ventrolateral prefrontal cortical and callosal volumes. An alerting cue attenuated age effects on conjunction search, and the alertness benefit was associated with thalamic, callosal, and temporal cortex volumes. Our results indicate that older adults can capitalize on early parallel stages of visual information processing, whereas age-related limitations arise at later serial processing stages requiring self-guided selective attention and executive control. These limitations are explained in part by age-related brain volume shrinkage and can be mitigated by external cues.
Quantitative three-dimensional transrectal ultrasound (TRUS) for prostate imaging
NASA Astrophysics Data System (ADS)
Pathak, Sayan D.; Aarnink, Rene G.; de la Rosette, Jean J.; Chalana, Vikram; Wijkstra, Hessel; Haynor, David R.; Debruyne, Frans M. J.; Kim, Yongmin
1998-06-01
With the number of men seeking medical care for prostate diseases rising steadily, the need of a fast and accurate prostate boundary detection and volume estimation tool is being increasingly experienced by the clinicians. Currently, these measurements are made manually, which results in a large examination time. A possible solution is to improve the efficiency by automating the boundary detection and volume estimation process with minimal involvement from the human experts. In this paper, we present an algorithm based on SNAKES to detect the boundaries. Our approach is to selectively enhance the contrast along the edges using an algorithm called sticks and integrate it with a SNAKES model. This integrated algorithm requires an initial curve for each ultrasound image to initiate the boundary detection process. We have used different schemes to generate the curves with a varying degree of automation and evaluated its effects on the algorithm performance. After the boundaries are identified, the prostate volume is calculated using planimetric volumetry. We have tested our algorithm on 6 different prostate volumes and compared the performance against the volumes manually measured by 3 experts. With the increase in the user inputs, the algorithm performance improved as expected. The results demonstrate that given an initial contour reasonably close to the prostate boundaries, the algorithm successfully delineates the prostate boundaries in an image, and the resulting volume measurements are in close agreement with those made by the human experts.
Whole genome sequence analyses of brain imaging measures in the Framingham Study.
Sarnowski, Chloé; Satizabal, Claudia L; DeCarli, Charles; Pitsillides, Achilleas N; Cupples, L Adrienne; Vasan, Ramachandran S; Wilson, James G; Bis, Joshua C; Fornage, Myriam; Beiser, Alexa S; DeStefano, Anita L; Dupuis, Josée; Seshadri, Sudha
2018-01-16
We sought to identify rare variants influencing brain imaging phenotypes in the Framingham Heart Study by performing whole genome sequence association analyses within the Trans-Omics for Precision Medicine Program. We performed association analyses of cerebral and hippocampal volumes and white matter hyperintensity (WMH) in up to 2,180 individuals by testing the association of rank-normalized residuals from mixed-effect linear regression models adjusted for sex, age, and total intracranial volume with individual variants while accounting for familial relatedness. We conducted gene-based tests for rare variants using (1) a sliding-window approach, (2) a selection of functional exonic variants, or (3) all variants. We detected new loci in 1p21 for cerebral volume (minor allele frequency [MAF] 0.005, p = 10 -8 ) and in 16q23 for hippocampal volume (MAF 0.05, p = 2.7 × 10 -8 ). Previously identified associations in 12q24 for hippocampal volume (rs7294919, p = 4.4 × 10 -4 ) and in 17q25 for WMH (rs7214628, p = 2.0 × 10 -3 ) were confirmed. Gene-based tests detected associations ( p ≤ 2.3 × 10 -6 ) in new loci for cerebral (5q13, 8p12, 9q31, 13q12-q13, 15q24, 17q12, 19q13) and hippocampal volumes (2p12) and WMH (3q13, 4p15) including Alzheimer disease- ( UNC5D ) and Parkinson disease-associated genes ( GBA ). Pathway analyses evidenced enrichment of associated genes in immunity, inflammation, and Alzheimer disease and Parkinson disease pathways. Whole genome sequence-wide search reveals intriguing new loci associated with brain measures. Replication of novel loci is needed to confirm these findings. Copyright © 2017 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Academy of Neurology.
Hoyng, Lieke L; Frings, Virginie; Hoekstra, Otto S; Kenny, Laura M; Aboagye, Eric O; Boellaard, Ronald
2015-01-01
Positron emission tomography (PET) with (18)F-3'-deoxy-3'-fluorothymidine ([(18)F]FLT) can be used to assess tumour proliferation. A kinetic-filtering (KF) classification algorithm has been suggested for segmentation of tumours in dynamic [(18)F]FLT PET data. The aim of the present study was to evaluate KF segmentation and its test-retest performance in [(18)F]FLT PET in non-small cell lung cancer (NSCLC) patients. Nine NSCLC patients underwent two 60-min dynamic [(18)F]FLT PET scans within 7 days prior to treatment. Dynamic scans were reconstructed with filtered back projection (FBP) as well as with ordered subsets expectation maximisation (OSEM). Twenty-eight lesions were identified by an experienced physician. Segmentation was performed using KF applied to the dynamic data set and a source-to-background corrected 50% threshold (A50%) was applied to the sum image of the last three frames (45- to 60-min p.i.). Furthermore, several adaptations of KF were tested. Both for KF and A50% test-retest (TRT) variability of metabolically active tumour volume and standard uptake value (SUV) were evaluated. KF performed better on OSEM- than on FBP-reconstructed PET images. The original KF implementation segmented 15 out of 28 lesions, whereas A50% segmented each lesion. Adapted KF versions, however, were able to segment 26 out of 28 lesions. In the best performing adapted versions, metabolically active tumour volume and SUV TRT variability was similar to those of A50%. KF misclassified certain tumour areas as vertebrae or liver tissue, which was shown to be related to heterogeneous [(18)F]FLT uptake areas within the tumour. For [(18)F]FLT PET studies in NSCLC patients, KF and A50% show comparable tumour volume segmentation performance. The KF method needs, however, a site-specific optimisation. The A50% is therefore a good alternative for tumour segmentation in NSCLC [(18)F]FLT PET studies in multicentre studies. Yet, it was observed that KF has the potential to subsegment lesions in high and low proliferative areas.
Breathing simulator of workers for respirator performance test.
Yuasa, Hisashi; Kumita, Mikio; Honda, Takeshi; Kimura, Kazushi; Nozaki, Kosuke; Emi, Hitoshi; Otani, Yoshio
2015-01-01
Breathing machines are widely used to evaluate respirator performance but they are capable of generating only limited air flow patterns, such as, sine, triangular and square waves. In order to evaluate the respirator performance in practical use, it is desirable to test the respirator using the actual breathing patterns of wearers. However, it has been a difficult task for a breathing machine to generate such complicated flow patterns, since the human respiratory volume changes depending on the human activities and workload. In this study, we have developed an electromechanical breathing simulator and a respiration sampling device to record and reproduce worker's respiration. It is capable of generating various flow patterns by inputting breathing pattern signals recorded by a computer, as well as the fixed air flow patterns. The device is equipped with a self-control program to compensate the difference in inhalation and exhalation volume and the measurement errors on the breathing flow rate. The system was successfully applied to record the breathing patterns of workers engaging in welding and reproduced the breathing patterns.
NASA Technical Reports Server (NTRS)
Abeles, F. J.
1980-01-01
The design of the prototype protective ensemble was finalized. Prototype ensembles were fabricated and then subjected to a series of qualification tests which were based upon the protective ensemble performance standards PEPS requirements. Engineering drawings and purchase specifications were prepared for the new protective ensemble.
ATS-6 engineering performance report. Volume 3: Telecommunications and power
NASA Technical Reports Server (NTRS)
Wales, R. O. (Editor)
1981-01-01
Functional design requirements and in-orbit operations, performance, and anomalies are discussed for (1) the communications subsystem, (2) the electrical power system, and (3) the telemetry and command subsystem. The latter includes a review of ground support. Tracking and data relay experiments and the Apollo-Soyuz test program are reviewed.
Hypothalamic tumors impact gray and white matter volumes in fronto-limbic brain areas.
Özyurt, Jale; Müller, Hermann L; Warmuth-Metz, Monika; Thiel, Christiane M
2017-04-01
Patients with hypothalamic involvement of a sellar/parasellar tumor often suffer from cognitive and social-emotional deficits that a lesion in the hypothalamus cannot fully explain. It is conceivable that these deficits are partly due to distal changes in hypothalamic networks, evolving secondary to a focal lesion. Focusing on childhood-onset craniopharyngioma patients, we aimed at investigating the impact of hypothalamic lesions on gray and white matter areas densely connected to the hypothalamus, and to relate structural changes to neuropsychological deficits frequently observed in patients. We performed a voxel-based morphometric analysis based on data of 11 childhood-onset craniopharyngioma patients with hypothalamic tumor involvement, and 18 healthy controls (median age: 17.2 and 17.4 yrs.). Whole-brain analyses were used to test for volumetric differences between the groups (T-tests) and subsequent regression analyses were used to correlate neuropsychological performance with gray and white matter volumes within the patient group. Patients compared to controls had significantly reduced gray matter volumes in areas of the anterior and posterior limbic subsystems which are densely connected with the hypothalamus. In addition, a reduction in white matter volumes was observed in tracts connecting the hypothalamus to other limbic areas. Worse long-term memory retrieval was correlated with smaller gray matter volumes in the posterior cingulate cortex. Our data provide the first evidence that hypothalamic tumor involvement impacts gray and white matter volumes in limbic areas, outside the area of tumor growth. Notably, the functional range of the two limbic subsystems affected, strikingly parallels the two major domains of psychological complaints in patients i.e., deficits in episodic memory and in socio-emotional functioning. We suggest that focal hypothalamic lesions may trigger distal changes in connected brain areas, which then contribute to the impairments in cognitive, social and emotional performance often observable in patients, and not explicable by a hypothalamic lesion alone. Copyright © 2017 Elsevier Ltd. All rights reserved.
Thalamic and hippocampal volume associated with memory functions in multiple sclerosis.
Tremblay, Alexandra; Jobin, Céline; Demers, Mélanie; Dagenais, Emmanuelle; Narayanan, Sridar; Araújo, David; Douglas, Arnold L; Roger, Elaine; Chamelian, Laury; Duquette, Pierre; Rouleau, Isabelle
2018-06-08
Although multiple sclerosis (MS) has long been considered to primarily affect white matter, it is now recognized that cognitive deficits in MS are also related to neocortical, thalamic and hippocampal damage. However, the association between damage to these structures and memory deficits in MS is unclear. This study examines whether MS patients with cognitive impairment have a reduction of hippocampal and/or thalamic volumes compared to cognitively intact patients, and whether these volume reductions correlate with various aspects of memory function. Volumetric MRI measures of thalamus and hippocampus of forty-one patients with MS were performed. The patients were divided in two groups depending on the presence or absence of cognitive impairment, based on their neuropsychological tests scores. Right hippocampal volume was found to be associated with learning, and the left thalamic volume was found to predict performance in verbal memory. Cognitively impaired patients had a tendency to have a reduced left thalamic volume compared to cognitively intact patients. This study does not support a direct relationship between hippocampal atrophy and verbal memory. These results add to the growing evidence of the involvement of thalamus in cognitive impairment in MS and its association with verbal memory deficits. Copyright © 2018. Published by Elsevier Inc.
Near-field Testing of the 15-meter Model of the Hoop Column Antenna
NASA Technical Reports Server (NTRS)
Hoover, J.; Kefauver, N.; Cencich, T.; Osborn, J.; Osmanski, J.
1986-01-01
The technical results from near-field testing of the 15-meter model of the hoop column antenna at the Martin Marietta Denver Aerospace facility are documented. The antenna consists of a deployable central column and a 15 meter hoop, stiffened by cables into a structure with a high tolerance repeatable surface and offset feed location. The surface has been configured to have four offset parabolic apertures, each about 6 meters in diameter, and is made of gold plated molybdenum wire mesh. Pattern measurements were made with feed systems radiating at frequencies of 7.73, 11.60, 2.27, 2.225, and 4.26 (all in GHz). This report (Volume 1) covers the testing from an overall viewpoint and contains information of generalized interest for testing large antennas. This volume discusses the deployment of the antenna in the Martin Facility and the measurements to determine mechanical stability and trueness of the reflector surface, gives the test program outline, and gives a synopsis of antenna electromagnetic performance. Three techniques for measuring surface mechanical tolerances were used (theodolites, metric cameras, and near-field phase), but only the near-field phase approach is included. The report also includes an error analysis. A detailed listing of the antenna patterns are provided for the 2.225 Ghz feed in Volume 3 of this report, and for all other feeds in Volume 2.
Schimpf, Karen J.; Meek, Claudia C.; Leff, Richard D.; Phelps, Dale L.; Schmitz, Daniel J.; Cordle, Christopher T.
2015-01-01
Inositol is a six-carbon sugar alcohol and is one of nine biologically significant isomers of hexahydroxycyclohexane. Myo-inositol is the primary biologically active form and is present in higher concentrations in the fetus and newborn than in adults. It is currently being examined for the prevention of retinopathy of prematurity in newborn preterm infants. A robust method for quantifying myo-inositol (MI), D-chiro-inositol (DCI) and 1,5-anhydro-D-sorbitol (ADS) in very small-volume (25 μL) urine, blood serum and/or plasma samples was developed. Using a multiple-column, multiple mobile phase liquid chromatographic system with electrochemical detection, the method was validated with respect to (a) selectivity, (b) accuracy/recovery, (c) precision/reproducibility, (d) sensitivity, (e) stability and (f) ruggedness. The standard curve was linear and ranged from 0.5 to 30 mg/L for each of the three analytes. Above-mentioned performance measures were within acceptable limits described in the Food and Drug Administration’s Guidance for Industry: Bioanalytical Method Validation. The method was validated using blood serum and plasma collected using four common anticoagulants, and also by quantifying the accuracy and sensitivity of MI measured in simulated urine samples recovered from preterm infant diaper systems. The method performs satisfactorily measuring the three most common inositol isomers on 25 μL clinical samples of serum, plasma milk, and/or urine. Similar performance is seen testing larger volume samples of infant formulas and infant formula ingredients. MI, ADS and DCI may be accurately tested in urine samples collected from five different preterm infant diapers if the urine volume is greater than 2–5 mL. PMID:26010453
Clinical biochemistry laboratory rejection rates due to various types of preanalytical errors.
Atay, Aysenur; Demir, Leyla; Cuhadar, Serap; Saglam, Gulcan; Unal, Hulya; Aksun, Saliha; Arslan, Banu; Ozkan, Asuman; Sutcu, Recep
2014-01-01
Preanalytical errors, along the process from the beginning of test requests to the admissions of the specimens to the laboratory, cause the rejection of samples. The aim of this study was to better explain the reasons of rejected samples, regarding to their rates in certain test groups in our laboratory. This preliminary study was designed on the rejected samples in one-year period, based on the rates and types of inappropriateness. Test requests and blood samples of clinical chemistry, immunoassay, hematology, glycated hemoglobin, coagulation and erythrocyte sedimentation rate test units were evaluated. Types of inappropriateness were evaluated as follows: improperly labelled samples, hemolysed, clotted specimen, insufficient volume of specimen and total request errors. A total of 5,183,582 test requests from 1,035,743 blood collection tubes were considered. The total rejection rate was 0.65 %. The rejection rate of coagulation group was significantly higher (2.28%) than the other test groups (P < 0.001) including insufficient volume of specimen error rate as 1.38%. Rejection rates of hemolysis, clotted specimen and insufficient volume of sample error were found to be 8%, 24% and 34%, respectively. Total request errors, particularly, for unintelligible requests were 32% of the total for inpatients. The errors were especially attributable to unintelligible requests of inappropriate test requests, improperly labelled samples for inpatients and blood drawing errors especially due to insufficient volume of specimens in a coagulation test group. Further studies should be performed after corrective and preventive actions to detect a possible decrease in rejecting samples.
Zhang, Ying; Alonzo, Todd A
2016-11-01
In diagnostic medicine, the volume under the receiver operating characteristic (ROC) surface (VUS) is a commonly used index to quantify the ability of a continuous diagnostic test to discriminate between three disease states. In practice, verification of the true disease status may be performed only for a subset of subjects under study since the verification procedure is invasive, risky, or expensive. The selection for disease examination might depend on the results of the diagnostic test and other clinical characteristics of the patients, which in turn can cause bias in estimates of the VUS. This bias is referred to as verification bias. Existing verification bias correction in three-way ROC analysis focuses on ordinal tests. We propose verification bias-correction methods to construct ROC surface and estimate the VUS for a continuous diagnostic test, based on inverse probability weighting. By applying U-statistics theory, we develop asymptotic properties for the estimator. A Jackknife estimator of variance is also derived. Extensive simulation studies are performed to evaluate the performance of the new estimators in terms of bias correction and variance. The proposed methods are used to assess the ability of a biomarker to accurately identify stages of Alzheimer's disease. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Fraello, David; Maller-Kesselman, Jill; Vohr, Betty; Katz, Karol H; Kesler, Shelli; Schneider, Karen; Reiss, Allan; Ment, Laura; Spann, Marisa N
2011-06-01
This study tested the hypothesis that preterm early adolescents' short-term memory is compromised when presented with increasingly complex verbal information and that associated neuroanatomical volumes would differ between preterm and term groups. Forty-nine preterm and 20 term subjects were evaluated at age 12 years with neuropsychological measures and magnetic resonance imaging (MRI). There were no differences between groups in simple short-term and working memory. Preterm subjects performed lower on learning and short-term memory tests that included increased verbal complexity. They had reduced right parietal, left temporal, and right temporal white matter volumes and greater bilateral frontal gray and right frontal white matter volumes. There was a positive association between complex working memory and the left hippocampus and frontal white matter in term subjects. While not correlated, memory scores and volumes of cortical regions known to subserve language and memory were reduced in preterm subjects. This study provides evidence of possible mechanisms for learning problems in former preterm infants.
Pulmonary function in adolescents with ataxia telangiectasia.
McGrath-Morrow, Sharon; Lefton-Greif, Maureen; Rosquist, Karen; Crawford, Thomas; Kelly, Amber; Zeitlin, Pamela; Carson, Kathryn A; Lederman, Howard M
2008-01-01
Pulmonary complications are common in adolescents with ataxia telangiectasia (A-T), however objective measurements of lung function may be difficult to obtain because of underlying bulbar weakness, tremors, and difficulty coordinating voluntary respiratory maneuvers. To increase the reliability of pulmonary testing, minor adjustments were made to stabilize the head and to minimize leaks in the system. Fifteen A-T adolescents completed lung volume measurements by helium dilution. To assess for reproducibility of spirometry testing, 10 A-T adolescents performed spirometry on three separate occasions. Total lung capacity (TLC) was normal or just mildly decreased in 12/15 adolescents tested. TLC correlated positively with functional residual capacity (FRC), a measurement independent of patient effort (R2=0.71). The majority of individuals had residual volumes (RV) greater than 120% predicted (10/15) and slow vital capacities (VC) less than 70% predicted (9/15). By spirometry, force vital capacity (FVC) and forced expiratory volume in 1 sec (FEV1) values were reproducible in the 10 individuals who underwent testing on three separate occasions (R=0.97 and 0.96 respectively). Seven of the 10 adolescents had FEV1/FVC ratios>90%. Lung volume measurements from A-T adolescents revealed near normal TLC values with increased RV and decreased VC values. These findings indicate a decreased ability to expire to residual volume rather then a restrictive defect. Spirometry was also found to be reproducible in A-T adolescents suggesting that spirometry testing may be useful for tracking changes in pulmonary function over time in this population. Copyright (c) 2007 Wiley-Liss, Inc.
Breadboard stellar tracker system test report, volume 2
NASA Technical Reports Server (NTRS)
1981-01-01
Complete data from a test program designed to evaluate the performance of a star tracker, a breadboard tracker system, is presented in tabular form. All data presented was normalized to the pixel dimension of 20 micrometers. Data from determination of maximum spatial noise as it applies to the coarse and fine acquisition modes is presented. Pointing accuracy test data, raw pixel data for the track cycle, and data from equipment related tests is also presented.
NASA Technical Reports Server (NTRS)
1979-01-01
The tests and procedures for the manned remote work station (MRWS) open cherry picker (OCP) development test article (DTA) are described to validate systems requirements and performance specifications. A development test program is outlined to evaluate key design issues and man/machine interfaces when the MRWS OCP is used in a shuttle support role of satellite servicing and in orbit construction of large structures.
Solid rocket booster performance evaluation model. Volume 1: Engineering description
NASA Technical Reports Server (NTRS)
1974-01-01
The space shuttle solid rocket booster performance evaluation model (SRB-II) is made up of analytical and functional simulation techniques linked together so that a single pass through the model will predict the performance of the propulsion elements of a space shuttle solid rocket booster. The available options allow the user to predict static test performance, predict nominal and off nominal flight performance, and reconstruct actual flight and static test performance. Options selected by the user are dependent on the data available. These can include data derived from theoretical analysis, small scale motor test data, large motor test data and motor configuration data. The user has several options for output format that include print, cards, tape and plots. Output includes all major performance parameters (Isp, thrust, flowrate, mass accounting and operating pressures) as a function of time as well as calculated single point performance data. The engineering description of SRB-II discusses the engineering and programming fundamentals used, the function of each module, and the limitations of each module.
Serbruyns, Leen; Leunissen, Inge; Huysmans, Toon; Cuypers, Koen; Meesen, Raf L; van Ruitenbeek, Peter; Sijbers, Jan; Swinnen, Stephan P
2015-04-01
Even though declines in sensorimotor performance during healthy aging have been documented extensively, its underlying neural mechanisms remain unclear. Here, we explored whether age-related subcortical atrophy plays a role in sensorimotor performance declines, and particularly during bimanual manipulative performance (Purdue Pegboard Test). The thalamus, putamen, caudate and pallidum of 91 participants across the adult lifespan (ages 20-79 years) were automatically segmented. In addition to studying age-related changes in the global volume of each subcortical structure, local deformations within these structures, indicative of subregional volume changes, were assessed by means of recently developed shape analyses. Results showed widespread age-related global and subregional atrophy, as well as some notable subregional expansion. Even though global atrophy failed to explain the observed performance declines with aging, shape analyses indicated that atrophy in left and right thalamic subregions, specifically subserving connectivity with the premotor, primary motor and somatosensory cortical areas, mediated the relation between aging and performance decline. It is concluded that subregional volume assessment by means of shape analyses offers a sensitive tool with high anatomical resolution in the search for specific age-related associations between brain structure and behavior. Copyright © 2015 Elsevier Ltd. All rights reserved.
Smitka, M; Puschmann, S; Buschhueter, D; Gerber, J C; Witt, M; Honeycutt, N; Abolmaali, N; Hummel, T
2012-01-16
Both amygdala (AG) and hippocampus (HC) are integral parts of the olfactory system. The present study, including a large number of healthy subjects, was performed to compare HC and AG volumes, measured by manual tracing, in relation to specific olfactory functions, including odor threshold, discrimination, identification, and odor memory tasks. It also aimed to provide age-related normative data about the volume of the HC and AG. A total of 117 healthy volunteers participated (age range 19-77 years, mean age 37 years; 62 women, 55 men). Using the "Sniffin' Sticks", subjects received lateralized tests for odor threshold, and odor discrimination. In addition, an odor memory and an odor identification task were performed bilaterally. A Mini-Mental-State test excluded dementia. MR scans were performed using a 1.5 T scanner for later manual volumetric measurements. Volumetric measurements exhibited a good reproducibility. The average volume for the right HC was 3.29 cm(3) (SD 0.47), for the left HC it was 3.15 cm(3) (SD 0.47). The average right AG had a volume of 1.60 cm(3) (SD 0.31), left 1.59 cm(3) (SD 0.3). Increasing age was accompanied by a decrease of HC and AG volumes, which were much more pronounced for the right compared to the left side. Only the volume of the right HC showed a small but significant correlation with odor threshold (r(117)=0.21; p=0.02). Importantly, this correlation was not mediated by age as indicated by the significant partial correlation when controlling for age (r(114)=0.18; p=0.049). In conclusion, the present data obtained in a relatively large group of subjects demonstrates a small correlation between the volume of the HC, as an integral part of the olfactory system, and smell function. In addition, these data can be used as the basis for normative values of HC and AG volumes, separately for men, women and different age groups. This is of potential interest in diseases with acute or chronic impairment of olfactory function, in metabolic or neurodegenerative diseases or in disorders with damage of areas involved in adult neurogenesis. Copyright © 2011 Elsevier Inc. All rights reserved.
Can technical factors explain the volume-outcome relationship in gastric bypass surgery?
Smith, Mark D; Patterson, Emma; Wahed, Abdus S; Belle, Steven H; Courcoulas, Anita P; Flum, David; Khandelwal, Saurabh; Mitchell, James E; Pomp, Alfons; Pories, Walter J; Wolfe, Bruce
2013-01-01
The existence of a relationship between surgeon volume and patient outcome has been reported for different complex surgical operations. This relationship has also been confirmed for patients undergoing Roux-en-Y gastric bypass (RYGB) in the Longitudinal Assessment of Bariatric Surgery (LABS) study. Despite multiple studies demonstrating volume-outcome relationships, fewer studies investigate the causes of this relationship. The purpose of the present study is to understand possible explanations for the volume-outcome relationship in LABS. LABS includes a 10-center, prospective study examining 30-day outcomes after bariatric surgery. The relationship between surgeon annual RYGB volume and incidence of a composite endpoint (CE) has been published previously. Technical aspects of RYGB surgery were compared between high and low volume surgeons. The previously published model was adjusted for select technical factors. High-volume surgeons (>100 RYGBs/yr) were more likely to perform a linear stapled gastrojejunostomy, use fibrin sealant, and place a drain at the gastrojejunostomy compared with low-volume surgeons (<25 RYGBs/yr), and less likely to perform an intraoperative leak test. After adjusting for the newly identified technical factors, the relative risk of CE was .93 per 10 RYGB/yr increase in volume, compared with .90 for clinical risk adjustment alone. High-volume surgeons exhibited certain differences in technique compared with low-volume surgeons. After adjusting for these differences, the strength of the volume-outcome relationship previously found was reduced only slightly, suggesting that other factors are also involved. Copyright © 2013 American Society for Bariatric Surgery. All rights reserved.
1983-02-01
Cultural Resources Survey, Harry S. Truman Dam 3 1 ,1rd Reservoir Projert, Missouri, Volumes I - X 6 PERFORMING ORG. REPORT NUMBER N/A 7. AUrHOR(*)Curtis H...A05TNACr ( towfs.e du e 81 f nevee" Old fdfliffV bw block niatber) The ten volumes report the results of a cultural resources survey in the Harry S...and Surf icial Geology of the Harry S. Truman Reservoir Area, West Central Missouri, by R. A. Ward and T. L. Thompson, pp. 1-21 part II: Report on
Longitudinal predictors of aerobic performance in adolescent soccer players.
Valente-dos-Santos, João; Coelho-e-Silva, Manuel J; Duarte, João; Figueiredo, António J; Liparotti, João R; Sherar, Lauren B; Elferink-Gemser, Marije T; Malina, Robert M
2012-01-01
The importance of aerobic performance in youth soccer is well established. The aim of the present study was to evaluate the contributions of chronological age (CA), skeletal age (SA), body size, and training to the longitudinal development of aerobic performance in youth male soccer players aged 10 to 18 years. Players (n=83) were annually followed up during 5 years, resulting in an average of 4.4 observations per player. Decimal CA was calculated, and SA, stature, body weight, and aerobic performance were measured once per year. Fat-free mass (FFM) was estimated from age- and gender-specific anthropometric formulas, and annual volume training was recorded. After testing for multicollinearity, multilevel regression modeling was used to analyze the longitudinal data aligned by CA and SA (Model 1 and 2, respectively) and to develop aerobic performance scores. The following equations provide estimations of the aerobic performance for young soccer players: ŷ(Model 1 [deviance from the null model =388.50; P<0.01]) =57.75+9.06×centered CA-0.57×centered CA(2)+0.03×annual volume training and ŷ(Model 2 [deviance from the null model=327.98; P<0.01])=13.03+4.04×centered SA-0.12×centered SA(2)+0.99×FFM+0.03×annual volume training. The development of aerobic performance in young soccer players was found to be significantly related to CA, biological development, and volume of training.
Feys, Peter; Moumdjian, Lousin; Van Halewyck, Florian; Wens, Inez; Eijnde, Bert O; Van Wijmeersch, Bart; Popescu, Veronica; Van Asch, Paul
2017-11-01
Exercise therapy studies in persons with multiple sclerosis (pwMS) primarily focused on motor outcomes in mid disease stage, while cognitive function and neural correlates were only limitedly addressed. This pragmatic randomized controlled study investigated the effects of a remotely supervised community-located "start-to-run" program on physical and cognitive function, fatigue, quality of life, brain volume, and connectivity. In all, 42 pwMS were randomized to either experimental (EXP) or waiting list control (WLC) group. The EXP group received individualized training instructions during 12 weeks (3×/week), to be performed in their community aiming to participate in a running event. Measures were physical (VO 2max , sit-to-stand test, Six-Minute Walk Test (6MWT), Multiple Sclerosis Walking Scale-12 (MSWS-12)) and cognitive function (Rao's Brief Repeatable Battery (BRB), Paced Auditory Serial Attention Test (PASAT)), fatigue (Fatigue Scale for Motor and Cognitive Function (FSMC)), quality of life (Multiple Sclerosis Impact Scale-29 (MSIS-29)), and imaging. Brain volumes and diffusion tensor imaging (DTI) were quantified using FSL-SIENA/FIRST and FSL-TBSS. In all, 35 pwMS completed the trial. Interaction effects in favor of the EXP group were found for VO 2max , sit-to-stand test, MSWS-12, Spatial Recall Test, FSMC, MSIS-29, and pallidum volume. VO 2max improved by 1.5 mL/kg/min, MSWS-12 by 4, FSMC by 11, and MSIS-29 by 14 points. The Spatial Recall Test improved by more than 10%. Community-located run training improved aerobic capacity, functional mobility, visuospatial memory, fatigue, and quality of life and pallidum volume in pwMS.
Track/train dynamics test report transfer function test. Volume 1: Test
NASA Technical Reports Server (NTRS)
Vigil, R. A.
1975-01-01
A description is presented of the transfer function test performed on an open hopper freight car loaded with 80 tons of coal. Test data and a post-test update of the requirements document and test procedure are presented. Included are a statement of the test objective, a description of the test configurations, test facilities, test methods, data acquisition/reduction operations, and a chronological test summary. An index to the data for the three test configurations (X, Y, and Z-axis tests) is presented along with test sequence, run number, test reference, and input parameters.
2004-02-01
UNCLASSIFIED − Conducted experiments to determine the usability of general-purpose anomaly detection algorithms to monitor a large, complex military...reaction and detection modules to perform tailored analysis sequences to monitor environmental conditions, health hazards and physiological states...scalability of lab proven anomaly detection techniques for intrusion detection in real world high volume environments. Narrative Title FY 2003
National Hydroelectric Power Resources Study:Regional Assessment: Volume XXIII: Alaska and Hawaii
1981-09-01
amount of recoverable geothermal energy is still unknown, a test well (HGP-A) was drilled 6,450 feet into the eastern rift of Kilauea volcano on...US Army Corps of Engineers National Hydroelectric Power Resources Study Volume XXIII September 1 981 Regional Assessment: Alaska and Hawaii ...National Hydroelectric Power Resources Study: Final Regional Assessment; Alaska and Hawaii IS. PERFORMING ORG. REPORT NUMBER IWR 82--23 7. AUTHOR(a) 8
LOGICAL REASONING ABILITY AND STUDENT PERFORMANCE IN GENERAL CHEMISTRY.
Bird, Lillian
2010-03-01
Logical reasoning skills of students enrolled in General Chemistry at the University of Puerto Rico in Río Piedras were measured using the Group Assessment of Logical Thinking (GALT) test. The results were used to determine the students' cognitive level (concrete, transitional, formal) as well as their level of performance by logical reasoning mode (mass/volume conservation, proportional reasoning, correlational reasoning, experimental variable control, probabilistic reasoning and combinatorial reasoning). This information was used to identify particular deficiencies and gender effects, and to determine which logical reasoning modes were the best predictors of student performance in the general chemistry course. Statistical tests to analyze the relation between (a) operational level and final grade in both semesters of the course; (b) GALT test results and performance in the ACS General Chemistry Examination; and (c) operational level and student approach (algorithmic or conceptual) towards a test question that may be answered correctly using either strategy, were also performed.
NASA Technical Reports Server (NTRS)
Sheth, Rubik B.; Stephan, Ryan A.; Hawkins-Reynolds Ebony
2011-01-01
Liquid/Liquid Heat Exchangers (L/L HX) are an integral portion of any spacecraft active thermal control system. For this study the X-38 L/L HX was used as a baseline. As detailed in a previous ICES manuscript, NASA paired with Pacific Northwest National Laboratory to develop a Microchannel L/L HX (MHX). This microchannel HX was designed to meet the same performance characteristics as the aforementioned X-38 HX. The as designed Microchannel HX has a 26% and 60% reduction in mass and volume, respectively. Due to the inherently smaller flow passages the design team was concerned about fouling affecting performance during extended missions. To address this concern, NASA has developed a test stand and is currently performing an 18 month life test on the MHX. This report will detail the up-to-date performance of the MHX during life testing.
LOGICAL REASONING ABILITY AND STUDENT PERFORMANCE IN GENERAL CHEMISTRY
Bird, Lillian
2010-01-01
Logical reasoning skills of students enrolled in General Chemistry at the University of Puerto Rico in Río Piedras were measured using the Group Assessment of Logical Thinking (GALT) test. The results were used to determine the students’ cognitive level (concrete, transitional, formal) as well as their level of performance by logical reasoning mode (mass/volume conservation, proportional reasoning, correlational reasoning, experimental variable control, probabilistic reasoning and combinatorial reasoning). This information was used to identify particular deficiencies and gender effects, and to determine which logical reasoning modes were the best predictors of student performance in the general chemistry course. Statistical tests to analyze the relation between (a) operational level and final grade in both semesters of the course; (b) GALT test results and performance in the ACS General Chemistry Examination; and (c) operational level and student approach (algorithmic or conceptual) towards a test question that may be answered correctly using either strategy, were also performed. PMID:21373364
Effect of laryngeal anesthesia on pulmonary function testing in normal subjects.
Kuna, S T; Woodson, G E; Sant'Ambrogio, G
1988-03-01
Pulmonary function tests (PFT) were performed on 11 normal subjects before and after topical anesthesia of the larynx. The PFT consisted of flow volume loops and body box determinations of functional residual capacity and airway resistance, each performed in triplicate. After the first set of tests, cotton pledgets soaked in 4% lidocaine were held in the pyriform sinuses for 2 min to block the superior laryngeal nerves. In addition, 1.5 ml of 10% cocaine was dropped on the vocal cords via indirect laryngoscopy. PFT were repeated 5 min after anesthesia. Besides routine analysis of the flow volume loops, areas under the inspiratory (Area I) and expiratory (Area E) portions of the loops were calculated by planimetry. Area I, peak inspiratory flow (PIF), as well as forced inspiratory flow at 25, 50, and 75% forced vital capacity (FVC), decreased after anesthesia. Peak expiratory flow decreased after anesthesia, but Area E and forced expiratory flow at 25, 50, and 75% FVC were unchanged. This protocol also was performed in 12 normal subjects with isotonic saline being substituted for the lidocaine and cocaine. In this group, no significant differences were observed when flow volume loop parameters were compared before and after topical application of saline. In 5 spontaneously breathing anesthetized dogs, posterior cricoarytenoid muscle and afferent superior laryngeal nerve activity were recorded before and after laryngeal anesthesia performed with the same procedure used in the human subjects. Laryngeal anesthesia resulted in a substantial decrease or a complete disappearance of afferent SLN activity recorded during unobstructed and obstructed respiration. The data suggest that laryngeal receptors help modulate upper airway patency in man.
NASA Technical Reports Server (NTRS)
Wales, R. O. (Editor)
1981-01-01
The overall mission and spacecraft systems, testing, and operations are summarized. The mechanical subsystems are reviewed, encompassing mechanical design requirements; separation and deployment mechanisms; design and performance evaluation; and the television camera reflector monitor. Thermal control and contamination are discussed in terms of thermal control subsystems, design validation, subsystems performance, the advanced flight experiment, and the quartz-crystal microbalance contamination monitor.
In-air versus underwater comparison of 3D reconstruction accuracy using action sport cameras.
Bernardina, Gustavo R D; Cerveri, Pietro; Barros, Ricardo M L; Marins, João C B; Silvatti, Amanda P
2017-01-25
Action sport cameras (ASC) have achieved a large consensus for recreational purposes due to ongoing cost decrease, image resolution and frame rate increase, along with plug-and-play usability. Consequently, they have been recently considered for sport gesture studies and quantitative athletic performance evaluation. In this paper, we evaluated the potential of two ASCs (GoPro Hero3+) for in-air (laboratory) and underwater (swimming pool) three-dimensional (3D) motion analysis as a function of different camera setups involving the acquisition frequency, image resolution and field of view. This is motivated by the fact that in swimming, movement cycles are characterized by underwater and in-air phases what imposes the technical challenge of having a split volume configuration: an underwater measurement volume observed by underwater cameras and an in-air measurement volume observed by in-air cameras. The reconstruction of whole swimming cycles requires thus merging of simultaneous measurements acquired in both volumes. Characterizing and optimizing the instrumental errors of such a configuration makes mandatory the assessment of the instrumental errors of both volumes. In order to calibrate the camera stereo pair, black spherical markers placed on two calibration tools, used both in-air and underwater, and a two-step nonlinear optimization were exploited. The 3D reconstruction accuracy of testing markers and the repeatability of the estimated camera parameters accounted for system performance. For both environments, statistical tests were focused on the comparison of the different camera configurations. Then, each camera configuration was compared across the two environments. In all assessed resolutions, and in both environments, the reconstruction error (true distance between the two testing markers) was less than 3mm and the error related to the working volume diagonal was in the range of 1:2000 (3×1.3×1.5m 3 ) to 1:7000 (4.5×2.2×1.5m 3 ) in agreement with the literature. Statistically, the 3D accuracy obtained in the in-air environment was poorer (p<10 -5 ) than the one in the underwater environment, across all the tested camera configurations. Related to the repeatability of the camera parameters, we found a very low variability in both environments (1.7% and 2.9%, in-air and underwater). This result encourage the use of ASC technology to perform quantitative reconstruction both in-air and underwater environments. Copyright © 2016 Elsevier Ltd. All rights reserved.
1990-09-01
and grouting were performed from the rock surface using expandable-air packers . Grouting was performed by injecting, into a hole, a neat grout ( cement ...Water & cement type I & II Mix: ........................... 6:1 to 0.75:1 Connection: .................... Air packer , close to surface...pressure tested then backfilled. The holes were hydraulic-pressure tested with a single air- expanding packer near the surface at 5 psi gauge pressure. If
Evaluation of metallized paint coatings for composite spacecraft structures
NASA Technical Reports Server (NTRS)
Brzuskiewicz, John E.
1990-01-01
The extreme temperature excursions of composite spacecraft structures in LEO must be minimized through the use of thermal-control coatings. Attention is presently given to tests of silicone resin coatings which were pigmented with either leafing aluminum or combinations of leafing aluminum with silicate-treated zinc oxide pigment. Atomic oxygen, UV/vacuum, and outgassing screening tests were conducted on several such coating formulations in order to characterize the performance characteristics of this coating concept. Performance was found to depend on pigment volume concentration.
Compact Deep-Space Optical Communications Transceiver
NASA Technical Reports Server (NTRS)
Roberts, W. Thomas; Charles, Jeffrey R.
2009-01-01
Deep space optical communication transceivers must be very efficient receivers and transmitters of optical communication signals. For deep space missions, communication systems require high performance well beyond the scope of mere power efficiency, demanding maximum performance in relation to the precious and limited mass, volume, and power allocated. This paper describes the opto-mechanical design of a compact, efficient, functional brassboard deep space transceiver that is capable of achieving megabyte-per-second rates at Mars ranges. The special features embodied to enhance the system operability and functionality, and to reduce the mass and volume of the system are detailed. System tests and performance characteristics are described in detail. Finally, lessons learned in the implementation of the brassboard design and suggestions for improvements appropriate for a flight prototype are covered.
Structural Neural Substrates of Reading the Mind in the Eyes.
Sato, Wataru; Kochiyama, Takanori; Uono, Shota; Sawada, Reiko; Kubota, Yasutaka; Yoshimura, Sayaka; Toichi, Motomi
2016-01-01
The ability to read the minds of others in their eyes plays an important role in human adaptation to social environments. Behavioral studies have resulted in the development of a test to measure this ability (Reading the Mind in the Eyes Test, revised version; Eyes Test), and have demonstrated that this ability is consistent over time. Although functional neuroimaging studies revealed brain activation while performing the Eyes Test, the structural neural substrates supporting consistent performance on the Eyes Test remain unclear. In this study, we assessed the Eyes Test and analyzed structural magnetic resonance images using voxel-based morphometry (VBM) in healthy participants. Test performance was positively associated with the gray matter volumes of the dorsomedial prefrontal cortex, inferior parietal lobule (temporoparietal junction), and precuneus in the left hemisphere. These results suggest that the fronto-temporoparietal network structures support the consistent ability to read the mind in the eyes.
Wen, Xin-Xin; Xu, Chao; Zong, Chun-Lin; Feng, Ya-Fei; Ma, Xiang-Yu; Wang, Fa-Qi; Yan, Ya-Bo; Lei, Wei
2016-07-01
Micro-finite element (μFE) models have been widely used to assess the biomechanical properties of trabecular bone. How to choose a proper sample volume of trabecular bone, which could predict the real bone biomechanical properties and reduce the calculation time, was an interesting problem. Therefore, the purpose of this study was to investigate the relationship between different sample volumes and apparent elastic modulus (E) calculated from μFE model. 5 Human lumbar vertebral bodies (L1-L5) were scanned by micro-CT. Cubic concentric samples of different lengths were constructed as the experimental groups and the largest possible volumes of interest (VOI) were constructed as the control group. A direct voxel-to-element approach was used to generate μFE models and steel layers were added to the superior and inferior surface to mimic axial compression tests. A 1% axial strain was prescribed to the top surface of the model to obtain the E values. ANOVA tests were performed to compare the E values from the different VOIs against that of the control group. Nonlinear function curve fitting was performed to study the relationship between volumes and E values. The larger cubic VOI included more nodes and elements, and more CPU times were needed for calculations. E values showed a descending tendency as the length of cubic VOI decreased. When the volume of VOI was smaller than (7.34mm(3)), E values were significantly different from the control group. The fit function showed that E values approached an asymptotic values with increasing length of VOI. Our study demonstrated that apparent elastic modulus calculated from μFE models were affected by the sample volumes. There was a descending tendency of E values as the length of cubic VOI decreased. Sample volume which was not smaller than (7.34mm(3)) was efficient enough and timesaving for the calculation of E. Copyright © 2016 Elsevier Ltd. All rights reserved.
Intranasal volume increases with age: Computed tomography volumetric analysis in adults.
Loftus, Patricia A; Wise, Sarah K; Nieto, Daniel; Panella, Nicholas; Aiken, Ashley; DelGaudio, John M
2016-10-01
It is theorized that intranasal cavity volumes change throughout the aging process, possibly secondary to hormonal changes and atrophy of the sinonasal mucosa. Our objective is to compare intranasal volumes from different age groups to test the hypothesis that intranasal cavity volume increases with age. Case series. An analysis of computed tomography (CT) scans performed for reasons other than sinonasal complaints. Intranasal volumes of three groups (age 20-30 years, 40-50 years, and 70 years and above) were calculated using Vitrea software. The total intranasal volume was measured from the nasal vestibule anteriorly, the nasopharynx posteriorly, the olfactory cleft superiorly, and the nasal floor inferiorly. The total volume included the sum of the right and left sides. Sixty-two CT scans were analyzed. There was a progressive, relatively linear, increase in intranasal volume with increasing age: 20 to 30 years = 15.73 mL, 40 to 50 years = 17.30 mL, and 70 years and above = 18.38 mL. Mean intranasal volume for males was 19.07 mL, and for females was 15.23 mL. Analysis of variance demonstrated significant group differences in mean intranasal volume for age (P = .003) and gender (P < .001), with moderate-to-large effect size of 0.206 and 0.289 (partial η(2) ), respectively. Post hoc testing revealed a significant difference between the 20 to 30-year and >70-year age groups (P = .006). There was no significant difference in intranasal volume dependent upon body mass index. Intranasal volume increases with age and is larger in males. Specific etiologies responsible for increased intranasal cavity volume with age are actively being evaluated. 4 Laryngoscope, 126:2212-2215, 2016. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
A data distributed parallel algorithm for ray-traced volume rendering
NASA Technical Reports Server (NTRS)
Ma, Kwan-Liu; Painter, James S.; Hansen, Charles D.; Krogh, Michael F.
1993-01-01
This paper presents a divide-and-conquer ray-traced volume rendering algorithm and a parallel image compositing method, along with their implementation and performance on the Connection Machine CM-5, and networked workstations. This algorithm distributes both the data and the computations to individual processing units to achieve fast, high-quality rendering of high-resolution data. The volume data, once distributed, is left intact. The processing nodes perform local ray tracing of their subvolume concurrently. No communication between processing units is needed during this locally ray-tracing process. A subimage is generated by each processing unit and the final image is obtained by compositing subimages in the proper order, which can be determined a priori. Test results on both the CM-5 and a group of networked workstations demonstrate the practicality of our rendering algorithm and compositing method.
A five week series of pilot-scale incineration tests, using a synthetic waste feed, was performed at the Environmental Protection Agency's Incineration Research Facility to evaluate the fate of trace metals fed to a rotary kiln incinerator. Eight tests studied the fate of five ha...
DOT National Transportation Integrated Search
2006-08-01
The objective of this study was to monitor and evaluate the performance of experimental full-depth repairs made with high-early-strength (HES) materials placed under Strategic Highway Research Program (SHRP) project C-206, Optimization of Highway Con...
77 FR 48505 - Submission for OMB Review; Comment Request-Flammability Standards for Carpets and Rugs
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-14
... passing test results, then only one test per year is required. For purposes of estimating burden, we have... mail/hand delivery/courier (for paper, disk, or CD-ROM submissions), preferably in five copies, to... to perform each year varies, depending upon the number of carpet styles and the annual volume of...
40 CFR 63.8687 - What performance tests, design evaluations, and other procedures must I use?
Code of Federal Regulations, 2010 CFR
2010-07-01
.... THC = Total hydrocarbon concentration at the combustion device outlet, parts per million by volume... auxiliary fuel, you must use Equation 6 of this section as follows: ER29AP03.005 Where: THC DE = THC... the test method specified in Table 3 to this subpart. THC = Total hydrocarbon concentration at the...
40 CFR 63.8687 - What performance tests, design evaluations, and other procedures must I use?
Code of Federal Regulations, 2014 CFR
2014-07-01
.... THC = Total hydrocarbon concentration at the combustion device outlet, parts per million by volume... auxiliary fuel, you must use Equation 6 of this section as follows: ER29AP03.005 Where: THC DE = THC... the test method specified in Table 3 to this subpart. THC = Total hydrocarbon concentration at the...
40 CFR 63.8687 - What performance tests, design evaluations, and other procedures must I use?
Code of Federal Regulations, 2012 CFR
2012-07-01
.... THC = Total hydrocarbon concentration at the combustion device outlet, parts per million by volume... auxiliary fuel, you must use Equation 6 of this section as follows: ER29AP03.005 Where: THC DE = THC... the test method specified in Table 3 to this subpart. THC = Total hydrocarbon concentration at the...
40 CFR 63.8687 - What performance tests, design evaluations, and other procedures must I use?
Code of Federal Regulations, 2013 CFR
2013-07-01
.... THC = Total hydrocarbon concentration at the combustion device outlet, parts per million by volume... auxiliary fuel, you must use Equation 6 of this section as follows: ER29AP03.005 Where: THC DE = THC... the test method specified in Table 3 to this subpart. THC = Total hydrocarbon concentration at the...
40 CFR 63.8687 - What performance tests, design evaluations, and other procedures must I use?
Code of Federal Regulations, 2011 CFR
2011-07-01
.... THC = Total hydrocarbon concentration at the combustion device outlet, parts per million by volume... auxiliary fuel, you must use Equation 6 of this section as follows: ER29AP03.005 Where: THC DE = THC... the test method specified in Table 3 to this subpart. THC = Total hydrocarbon concentration at the...
Neuroanatomical correlates of performance in a state-wide test of math achievement.
Wilkey, Eric D; Cutting, Laurie E; Price, Gavin R
2018-03-01
The development of math skills is a critical component of early education and a strong indicator of later school and economic success. Recent research utilizing population-normed, standardized measures of math achievement suggest that structural and functional integrity of parietal regions, especially the intraparietal sulcus, are closely related to the development of math skills. However, it is unknown how these findings relate to in-school math learning. The present study is the first to address this issue by investigating the relationship between regional differences in grey matter (GM) volume and performance in grade-level mathematics as measured by a state-wide, school-based test of math achievement (TCAP math) in children from 3rd to 8th grade. Results show that increased GM volume in the bilateral hippocampal formation and the right inferior frontal gyrus, regions associated with learning and memory, is associated with higher TCAP math scores. Secondary analyses revealed that GM volume in the left angular gyrus had a stronger relationship to TCAP math in grades 3-4 than in grades 5-8 while the relationship between GM volume in the left inferior frontal gyrus and TCAP math was stronger for grades 5-8. These results suggest that the neuroanatomical architecture related to in-school math achievement differs from that related to math achievement measured by standardized tests, and that the most related neural structures differ as a function of grade level. We suggest, therefore, that the use of school-relevant outcome measures is critical if neuroscience is to bridge the gap to education. © 2017 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Wei, Xin; Sun, Bing
2011-10-01
The fluid-structure interaction may occur in space launch vehicles, which would lead to bad performance of vehicles, damage equipments on vehicles, or even affect astronauts' health. In this paper, analysis on dynamic behavior of liquid oxygen (LOX) feeding pipe system in a large scale launch vehicle is performed, with the effect of fluid-structure interaction (FSI) taken into consideration. The pipe system is simplified as a planar FSI model with Poisson coupling and junction coupling. Numerical tests on pipes between the tank and the pump are solved by the finite volume method. Results show that restrictions weaken the interaction between axial and lateral vibrations. The reasonable results regarding frequencies and modes indicate that the FSI affects substantially the dynamic analysis, and thus highlight the usefulness of the proposed model. This study would provide a reference to the pipe test, as well as facilitate further studies on oscillation suppression.
21 CFR 862.1130 - Blood volume test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Blood volume test system. 862.1130 Section 862....1130 Blood volume test system. (a) Identification. A blood volume test system is a device intended to measure the circulating blood volume. Blood volume measurements are used in the diagnosis and treatment of...
NASA Technical Reports Server (NTRS)
Mchugh, F. J.; Eason, W.; Alexander, H. R.; Mutter, H.
1973-01-01
Wind tunnel test data obtained from a 1/4.622 Froude scale Boeing Model 222 with a full span, two prop, tilt rotor, powered model in the Boeing V/STOL wind tunnel are reported. Data were taken in transition and cruise flight conditions and include performance, stability and control and blade loads information. The effects of the rotors, tail surfaces and airframe on the performance and stability are isolated as are the effects of the airframe on the rotors.
Code of Federal Regulations, 2013 CFR
2013-07-01
... to or less than 10.0 parts per million by volume-wet THC as propane corrected to 3.0 percent carbon... 2A at 40 CFR part 60, appendix A-1. Record the start and stop reading for each 60-minute THC test. Record the gas pressure and temperature at 5-minute intervals throughout each 60-minute THC test. (iii...
DOT National Transportation Integrated Search
2008-09-01
A total of 49 dynamic sled tests were performed with the Hybrid III 10YO to examine issues relating to child belt fit. The goals of these tests were to evaluate ATD response to realistic belt geometries and belt fit, develop methods for accurate, rep...
Mendelson, Monique; Michallet, Anne-Sophie; Perrin, Claudine; Levy, Patrick; Wuyam, Bernard; Flore, Patrice
2014-08-15
We aimed to examine ventilatory responses during the six-minute walk test in healthy-weight and obese adolescents before and after exercise training. Twenty obese adolescents (OB) (age: 14.5±1.7 years; BMI: 34.0±4.7kg·m(-2)) and 20 age and gender-matched healthy-weight adolescents (HW) (age: 15.5±1.5 years; BMI: 19.9±1.4kg·m(-2)) completed six-minute walk test during which breath-by-breath gas analysis and expiratory flow limitation (expFL) were measured. OB participated in a 12-week exercise-training program. Comparison between HW and OB participants showed lower distance achieved during the 6MWT in OB (-111.0m, 95%CI: -160.1 to 62.0, p<0.05) and exertional breathlessness was greater (+0.78 a.u., 95%CI: 0.091-3.27, p=0.039) when compared with HW. Obese adolescents breathed at lower lung volumes, as evidenced by lower end expiratory and end inspiratory lung volumes during exercise (p<0.05). Prevalence of expFL (8 OB vs 2 HW, p=0.028) and mean expFL (14.9±21.9 vs 5.32±14.6% VT, p=0.043, in OB and HW) were greater in OB. After exercise training, mean increase in the distance achieved during the 6MWT was 64.5 meters (95%CI: 28.1-100.9, p=0.014) and mean decrease in exertional breathlessness was 1.62 (95%CI: 0.47-2.71, p=0.05). Obese adolescents breathed at higher lung volumes, as evidenced by the increase in end inspiratory lung volume from rest to 6-min exercise (9.9±13.4 vs 20.0±13.6%TLC, p<0.05). Improved performance was associated with improved change in end inspiratory lung volume from rest to 6-min exercise (r=0.65, p=0.025). Our results suggest that exercise training can improve breathing strategy during submaximal exercise in obese adolescents and that this increase is associated with greater exercise performance. Copyright © 2014 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Yuzdepski, I., Comp.; Elliott, L., Comp.
This document presents information, in the form of summary sheets, on 54 teacher evaluation instruments. Each summary contains pertinent information about the instrument regarding publishing company, author, criteria evaluated, subject of observation, category dimension, and coding units. The 19 criteria used in the evaluation tests, which were…
ERIC Educational Resources Information Center
Foster, Erin R.; Black, Kevin J.; Antenor-Dorsey, Jo Ann V.; Perlmutter, Joel S.; Hershey, Tamara
2008-01-01
Studies suggest motor deficit asymmetry may help predict the pattern of cognitive impairment in individuals with Parkinson disease (PD). We tested this hypothesis using a highly validated and sensitive spatial memory task, spatial delayed response (SDR), and clinical and neuroimaging measures of PD asymmetry. We predicted SDR performance would be…
40 CFR Table 1 to Subpart III of... - Emission Limitations
Code of Federal Regulations, 2011 CFR
2011-07-01
... determining compliance using this method Cadmium 0.004 milligrams per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Performance test (Method 29 of appendix A of part 60). Carbon monoxide 157 parts per million by dry volume 3-run average (1 hour minimum sample time per run) Performance...
40 CFR Table 1 to Subpart III of... - Emission Limitations
Code of Federal Regulations, 2010 CFR
2010-07-01
... determining compliance using this method Cadmium 0.004 milligrams per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Performance test (Method 29 of appendix A of part 60). Carbon monoxide 157 parts per million by dry volume 3-run average (1 hour minimum sample time per run) Performance...
Lung volumes during sustained microgravity on Spacelab SLS-1
NASA Technical Reports Server (NTRS)
Elliott, Ann R.; Prisk, G. Kim; Guy, Harold J. B.; West, John B.
1994-01-01
Gravity is known to influence the mechanical behavior of the lung and chest wall. However, the effect of sustained microgravity (microgravity) on lung volumes has not been reported. Pulmonary function tests were performed by four subjects before, during, and after 9 days of microgravity exposure. Ground measurements were made in standing and supine postures. Tests were performed using a bag-in-box-and-flowmeter system and a respiratory mass spectrometer. Measurements included functional residual capacity (FRC), expiratory reserve volume (ERV), residual volume (RV), inspiratory and expiratory vital capacities (IVC and EVC), and tidal volume (V9sub T)). Total lung capacity (TLC) was derived from the measured EVC and RV values. With preflight standing values as a comparison, FRC was significantly reduced by 15% (approximately 500 ml) in microgravity and 32% in the supine posture. ERV was reduced by 10 - 20% in microgravity and decreased by 64% in the supine posture. RV was significantly reduced by 18% (310 ml) in microgravity but did not significantly change in the supine posture compared with standing. IVC and EVC were slightly reduced during the first 24 h of microgravity but returned to 1-G standing values within 72 h of microgravity exposure. IVC and EVC in the supine posture were significantly reduced by 12% compared with standing. During microgravity, V(sub T) decreased by 15% (approximately 90 ml), but supine V(sub T) was unchanged compared with preflight standing values. TLC decreased by approximately 8% during microgravity and in the supine posture compared with preflight standing. The reductions in FRC, ERV, and RV during microgravity are probably due to the cranial shift of the diaphragm, an increase in intrathoracic blood volume, and more uniform alveolar expansion.
Lung volumes during sustained microgravity on Spacelab SLS-1.
Elliott, A R; Prisk, G K; Guy, H J; West, J B
1994-10-01
Gravity is known to influence the mechanical behavior of the lung and chest wall. However, the effect of sustained microgravity (mu G) on lung volumes has not been reported. Pulmonary function tests were performed by four subjects before, during, and after 9 days of mu G exposure. Ground measurements were made in standing and supine postures. Tests were performed using a bag-in-box-and-flowmeter system and a respiratory mass spectrometer. Measurements included functional residual capacity (FRC), expiratory reserve volume (ERV), residual volume (RV), inspiratory and expiratory vital capacities (IVC and EVC), and tidal volume (VT). Total lung capacity (TLC) was derived from the measured EVC and RV values. With preflight standing values as a comparison, FRC was significantly reduced by 15% (approximately 500 ml) in mu G and 32% in the supine posture. ERV was reduced by 10-20% in mu G and decreased by 64% in the supine posture. RV was significantly reduced by 18% (310 ml) in mu G but did not significantly change in the supine posture compared with standing. IVC and EVC were slightly reduced during the first 24 h of mu G but returned to 1-G standing values within 72 h of mu G exposure. IVC and EVC in the supine posture were significantly reduced by 12% compared with standing. During mu G, VT decreased by 15% (approximately 90 ml), but supine VT was unchanged compared with preflight standing values. TLC decreased by approximately 8% during mu G and in the supine posture compared with preflight standing. The reductions in FRC, ERV, and RV during mu G are probably due to the cranial shift of the diaphragm, an increase in intrathoracic blood volume, and more uniform alveolar expansion.
USAF Test Pilot School. Flying Qualities Textbook, Volume 2, Part 1
1986-04-01
Qualities Flight Testing, Performance and Flying Qaulities Branch, Flight Test Engneerd ision, 6510th Test Wing, Air Force Flight Mayst Ce1ter, Edwards...For these aircraft, the program manager may re*uire a mil spec written specifically for the aircraft and control system involwd. 5.20.2 _EL k,Tt...OR MANAGED IN CONTEXT OF MISSION, WITH AVAILABLE PILOT ATTENTION. S UNCONTROLLABLE CONTROL WILL BE LOST DURING SOME PORTION OF MISSION. ACCEPTABLE
Na, J U; Han, S K; Choi, P C; Cho, J H; Shin, D H
2013-10-01
Different face mask designs can influence bag-valve-mask (BVM) ventilation performance during resuscitation. We compared a single-use, air-cushioned face mask (AM) with a reusable silicone face mask (SM) for quality of BVM ventilation on a manikin simulating cardiac arrest. Thirty-two physicians were recruited, and a prospective, randomized, crossover observational study was conducted after an American Heart Association-accredited basic life support provider course and standardized practice time were completed. Participants performed 12 cycles of BVM ventilation with both the AM and SM on a SmartMan lung simulator. Mean tidal volume was significantly higher in ventilations performed using the AM vs. the SM (548 ± 159 ml vs. 439 ± 163 ml, P < 0.01). In addition, the proportion of low-volume ventilation was significantly lower with the AM than the SM [6/12 (2-11) vs. 9/12 (5-12), P = 0.03]. Bag-valve-AM ventilation volume was not affected by the physical characteristics of the rescuers, except for sex. In contrast, bag-valve-SM ventilation volume was affected by most of the characteristics tested, including sex, height, weight, hand width, hand length, and grip power. The AM seems to be a more efficient face mask than the SM at delivering sufficient ventilation volumes. The performance of the AM did not seem to be associated with the physical characteristics of the rescuers, whereas that of the SM was affected by these factors. The SM may not be an appropriate face mask for performing one-person BVM ventilation during resuscitation for rescuers who are smaller in stature, have a smaller hand size, or have weaker grip power. © 2013 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Validation of ultrasonography of the thyroid gland for epidemiological purposes.
Knudsen, N; Bols, B; Bülow, I; Jørgensen, T; Perrild, H; Ovesen, L; Laurberg, P
1999-11-01
Ultrasonography of the thyroid is often used in epidemiological surveys, thus thorough characterization of the interobserver variation of the different parameters obtained is important. Various methods have been used for measuring thyroid volume, and different formulas have been used for calculation of thyroid volume from the measured dimensions. In this article, two principles of thyroid volume measurement are described in detail: the wellknown method based on the three axes of each lobe and a new principle based on planimetry in two planes. The interobserver variation of the examination and the measuring procedure in itself were tested on 25 participants in a population study. A comparison of postmortem ultrasonography of the thyroid and results of an autopsy was performed. Good correlation and agreement between observers was found for thyroid volume (r = 0.98) and prevalence of thyroid nodules (kappa = 0.72), whereas echogenecity and echopattern showed little agreement. The correlation of thyroid volume by ultrasonography to autopsy results was satisfactory (r = 0.93), but the volume tended to be slightly underestimated even when using the formula pi/6(= 0.52)*length*width*depth. No major differences were found between the performance of the two principles of volume calculation. We conclude that when the measuring procedure is well defined, results of ultrasonography are comparable between observers for thyroid volume and prevalence of thyroid nodules, but not for echogenecity or echopattern. The formula of length*depth*width*pi/6 is suitable for thyroid volume measurement.
Han, Doug Hyun; Lyoo, In Kyoon; Renshaw, Perry F.
2015-01-01
Patients with on-line game addiction (POGA) and professional video game players play video games for extended periods of time, but experience very different consequences for their on-line game play. Brain regions consisting of anterior cingulate, thalamus and occpito-temporal areas may increase the likelihood of becoming a pro-gamer or POGA. Twenty POGA, seventeen pro-gamers, and eighteen healthy comparison subjects (HC) were recruited. All magnetic resonance imaging (MRI) was performed on a 1.5 Tesla Espree MRI scanner (SIEMENS, Erlangen, Germany). Voxel-wise comparisons of gray matter volume were performed between the groups using the two-sample t-test with statistical parametric mapping (SPM5). Compared to HC, the POGA group showed increased impulsiveness and perseverative errors, and volume in left thalamus gray matter, but decreased gray matter volume in both inferior temporal gyri, right middle occipital gyrus, and left inferior occipital gyrus, compared with HC. Pro-gamers showed increased gray matter volume in left cingulate gyrus, but decreased gray matter volume in left middle occipital gyrus and right inferior temporal gyrus compared with HC. Additionally, the pro-gamer group showed increased gray matter volume in left cingulate gyrus and decreased left thalamus gray matter volume compared with the POGA group. The current study suggests that increased gray matter volumes of the left cingulate gyrus in pro-gamers and of the left thalamus in POGA may contribute to the different clinical characteristics of pro-gamers and POGA. PMID:22277302
Bench performance of ventilators during simulated paediatric ventilation.
Park, M A J; Freebairn, R C; Gomersall, C D
2013-05-01
This study compares the accuracy and capabilities of various ventilators using a paediatric acute respiratory distress syndrome lung model. Various compliance settings and respiratory rate settings were used. The study was done in three parts: tidal volume and FiO2 accuracy; pressure control accuracy and positive end-expiratory pressure (PEEP) accuracy. The parameters set on the ventilator were compared with either or both of the measured parameters by the test lung and the ventilator. The results revealed that none of the ventilators could consistently deliver tidal volumes within 1 ml/kg of the set tidal volume, and the discrepancy between the delivered volume and the volume measured by the ventilator varied greatly. The target tidal volume was 8 ml/kg, but delivered tidal volumes ranged from 3.6-11.4 ml/kg and the volumes measured by the ventilator ranged from 4.1-20.6 ml/kg. All the ventilators maintained pressure within 20% of the set pressure, except one ventilator which delivered pressures of up to 27% higher than the set pressure. Two ventilators maintained PEEP within 10% of the prescribed PEEP. The majority of the readings were also within 10%. However, three ventilators delivered, at times, PEEPs over 20% higher. In conclusion, as lung compliance decreases, especially in paediatric patients, some ventilators perform better than others. This study highlights situations where ventilators may not be able to deliver, nor adequately measure, set tidal volumes, pressure, PEEP or FiO2.
Partial volume correction using cortical surfaces
NASA Astrophysics Data System (ADS)
Blaasvær, Kamille R.; Haubro, Camilla D.; Eskildsen, Simon F.; Borghammer, Per; Otzen, Daniel; Ostergaard, Lasse R.
2010-03-01
Partial volume effect (PVE) in positron emission tomography (PET) leads to inaccurate estimation of regional metabolic activities among neighbouring tissues with different tracer concentration. This may be one of the main limiting factors in the utilization of PET in clinical practice. Partial volume correction (PVC) methods have been widely studied to address this issue. MRI based PVC methods are well-established.1 Their performance depend on the quality of the co-registration of the MR and PET dataset, on the correctness of the estimated point-spread function (PSF) of the PET scanner and largely on the performance of the segmentation method that divide the brain into brain tissue compartments.1, 2 In the present study a method for PVC is suggested, that utilizes cortical surfaces, to obtain detailed anatomical information. The objectives are to improve the performance of PVC, facilitate a study of the relationship between metabolic activity in the cerebral cortex and cortical thicknesses, and to obtain an improved visualization of PET data. The gray matter metabolic activity after performing PVC was recovered by 99.7 - 99.8 % , in relation to the true activity when testing on simple simulated data with different PSFs and by 97.9 - 100 % when testing on simulated brain PET data at different cortical thicknesses. When studying the relationship between metabolic activities and anatomical structures it was shown on simulated brain PET data, that it is important to correct for PVE in order to get the true relationship.
Daugherty, Ana M.; Raz, Naftali
2016-01-01
Age-related declines in spatial navigation are associated with deficits in procedural and episodic memory and deterioration of their neural substrates. For the lack of longitudinal evidence, the pace and magnitude of these declines and their neural mediators remain unclear. Here we examined virtual navigation in healthy adults (N=213, age 18–77 years) tested twice, two years apart, with complementary indices of navigation performance (path length and complexity) measured over six learning trials at each occasion. Slopes of skill acquisition curves and longitudinal change therein were estimated in structural equation modeling, together with change in regional brain volumes and iron content (R2* relaxometry). Although performance on the first trial did not differ between occasions separated by two years, the slope of path length improvement over trials was shallower and end-of-session performance worse at follow-up. Advanced age, higher pulse pressure, smaller cerebellar and caudate volumes, and greater caudate iron content were associated with longer search paths, i.e. poorer navigation performance. In contrast, path complexity diminished faster over trials at follow-up, albeit less so in older adults. Improvement in path complexity after two years was predicted by lower baseline hippocampal iron content and larger parahippocampal volume. Thus, navigation path length behaves as an index of perceptual-motor skill that is vulnerable to age-related decline, whereas path complexity may reflect cognitive mapping in episodic memory that improves with repeated testing, although not enough to overcome age-related deficits. PMID:27659539
Daugherty, Ana M; Raz, Naftali
2017-02-01
Age-related declines in spatial navigation are associated with deficits in procedural and episodic memory and deterioration of their neural substrates. For the lack of longitudinal evidence, the pace and magnitude of these declines and their neural mediators remain unclear. Here we examined virtual navigation in healthy adults (N=213, age 18-77 years) tested twice, two years apart, with complementary indices of navigation performance (path length and complexity) measured over six learning trials at each occasion. Slopes of skill acquisition curves and longitudinal change therein were estimated in structural equation modeling, together with change in regional brain volumes and iron content (R2* relaxometry). Although performance on the first trial did not differ between occasions separated by two years, the slope of path length improvement over trials was shallower and end-of-session performance worse at follow-up. Advanced age, higher pulse pressure, smaller cerebellar and caudate volumes, and greater caudate iron content were associated with longer search paths, i.e. poorer navigation performance. In contrast, path complexity diminished faster over trials at follow-up, albeit less so in older adults. Improvement in path complexity after two years was predicted by lower baseline hippocampal iron content and larger parahippocampal volume. Thus, navigation path length behaves as an index of perceptual-motor skill that is vulnerable to age-related decline, whereas path complexity may reflect cognitive mapping in episodic memory that improves with repeated testing, although not enough to overcome age-related deficits. Copyright © 2016 Elsevier Inc. All rights reserved.
Guo, Yane; Zhang, Zengqiang; Zhou, Bo; Wang, Pan; Yao, Hongxiang; Yuan, Minshao; An, Ningyu; Dai, Haitao; Wang, Luning; Zhang, Xi; Liu, Yong
2014-06-01
Specific patterns of brain atrophy may be helpful in the diagnosis of Alzheimer's disease (AD). In the present study, we set out to evaluate the utility of grey-matter volume in the classification of AD and amnestic mild cognitive impairment (aMCI) compared to normal control (NC) individuals. Voxel-based morphometric analyses were performed on structural MRIs from 35 AD patients, 27 aMCI patients, and 27 NC participants. A two-sample two-tailed t-test was computed between the NC and AD groups to create a map of abnormal grey matter in AD. The brain areas with significant differences were extracted as regions of interest (ROIs), and the grey-matter volumes in the ROIs of the aMCI patients were included to evaluate the patterns of change across different disease severities. Next, correlation analyses between the grey-matter volumes in the ROIs and all clinical variables were performed in aMCI and AD patients to determine whether they varied with disease progression. The results revealed significantly decreased grey matter in the bilateral hippocampus/parahippocampus, the bilateral superior/middle temporal gyri, and the right precuneus in AD patients. The grey-matter volumes were positively correlated with clinical variables. Finally, we performed exploratory linear discriminative analyses to assess the classifying capacity of grey-matter volumes in the bilateral hippocampus and parahippocampus among AD, aMCI, and NC. Leave-one-out cross-validation analyses demonstrated that grey-matter volumes in hippocampus and parahippocampus accurately distinguished AD from NC. These findings indicate that grey-matter volumes are useful in the classification of AD.
Subregional volumes of the hippocampus in relation to cognitive function and risk of dementia.
Evans, Tavia E; Adams, Hieab H H; Licher, Silvan; Wolters, Frank J; van der Lugt, Aad; Ikram, M Kamran; O'Sullivan, Michael J; Vernooij, Meike W; Ikram, M Arfan
2018-05-18
Total hippocampal volume has been consistently linked to cognitive function and dementia. Yet, given its complex and parcellated internal structure, the role of subregions of the hippocampus in cognition and risk of dementia remains relatively underexplored. We studied subregions of the hippocampus in a large population-based cohort to further understand their role in cognitive impairment and dementia risk. We studied 5035 dementia- and stroke-free persons from the Rotterdam Study, aged over 45 years. All participants underwent magnetic resonance imaging (1.5 T) between 2005 and 2015. Automatic segmentation of the hippocampus and 12 of its subregions was performed using the FreeSurfer software (version 6.0). A cognitive test battery was performed, and participants were followed up for the development of dementia until 2015. Associations of hippocampal subregion volumes with cognition and incident dementia were examined using linear and Cox regression models, respectively. All analyses were adjusted for age, sex, education, and total hippocampal volume. Mean age was 64.3 years (SD 10.6) with 56% women. Smaller volumes of the hippocampal fimbria, presubiculum and subiculum showed the strongest associations with poor performance on several cognitive domains, including executive function but not memory. During a mean follow-up of 5.5 years, 76 persons developed dementia. Smaller subiculum volume was associated with risk of dementia adjusted for total volume (hazard ratio per SD decrease in volume: 1.75, 95% confidence interval 1.35; 2.26). In a community-dwelling non-demented population, we describe patterns of association between hippocampal subregions with cognition and risk of dementia. Specifically, the subiculum was associated with both poorer cognition and higher risk of dementia. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.
Gaffin, Jonathan M.; Shotola, Nancy Lichtenberg; Martin, Thomas R.; Phipatanakul, Wanda
2010-01-01
Rationale In 2007 the American Thoracic Society (ATS) recommended guidelines for acceptability and repeatability for assessing spirometry in preschool children. The authors aim to determine the feasibility of spirometry among children in this age group performing spirometry for the first time in a busy clinical practice. Methods First-time spirometry for children age 4 to 5 years old was selected from the Children’s Hospital Boston Pulmonary Function Test (PFT) database. Maneuvers were deemed acceptable if (1) the flow-volume loop showed rapid rise and smooth descent; (2) the back extrapolated volume (Vbe), the volume leaked by a subject prior to the forced maneuver, was ≤80 ml and 12.5% of forced vital capacity (FVC); and (3) cessation of expiratory flow was at a point ≤10% of peak expiratory flow rate (PEFR). Repeatability was determined by another acceptable maneuver with forced expiratory volume in t seconds (FEVt) and FVC within 10% or 0.1 L of the best acceptable maneuver. Post hoc analysis compared spirometry values for those with asthma and cystic fibrosis to normative values. Results Two hundred and forty-eight preschool children performed spirometry for the first time between August 26, 2006, and August 25, 2008. At least one technically acceptable maneuver was found in 82.3% (n = 204) of the tests performed. Overall, 54% of children were able to perform acceptable and repeatable spirometry based on the ATS criteria. Children with asthma or cystic fibrosis did not have spirometry values that differed significantly from healthy controls. However, up to 29% of the overall cohort displayed at least one abnormal spirometry value. Conclusions Many preschool-aged children are able to perform technically acceptable and repeatable spirometry under normal conditions in a busy clinical setting. Spirometry may be a useful screen for abnormal lung function in this age group. PMID:20653495
Code of Federal Regulations, 2013 CFR
2013-07-01
... per million dry volume 3-run average (1 hour minimum sample time per run) Performance test (Method 10..., appendix A-3 or appendix A-8). Sulfur dioxide 11 parts per million dry volume 3-run average (1 hour minimum... Apply to Incinerators on and After [Date to be specified in state plan] a 6 Table 6 to Subpart DDDD of...
Code of Federal Regulations, 2014 CFR
2014-07-01
... per million dry volume 3-run average (1 hour minimum sample time per run) Performance test (Method 10..., appendix A-3 or appendix A-8). Sulfur dioxide 11 parts per million dry volume 3-run average (1 hour minimum... Apply to Incinerators on and After [Date to be specified in state plan] a 6 Table 6 to Subpart DDDD of...
Gibson, Ann L; Roper, Jenevieve L; Mermier, Christine M
2016-10-01
Air displacement plethysmography (ADP) is a popular method for estimating body density (Db). Most ADP tests are performed once, with test-retest investigations scarce. Therefore, we investigated test-retest reliability of ADP. Active men (n = 25) and women (n = 25) volunteered and followed standard pretest guidelines. Participants wore dry, form-fitting swimwear and manufacturer-supplied swim caps. In a single session, two ADP trials with measured thoracic gas volume (TGV) were performed without repositioning participants. Separate 2 (sex) × 2 (ADP trial) repeated-measures ANOVAs were performed to investigate within-between comparisons of Db, TGV, body volume (Vb), and relative fatness (%BF). Paired t tests were used to investigate significant differences as appropriate. The Bland and Altman technique was used to depict individual intertrial variations. For all analyses, α =.05. A significant main effect for sex was found; men were lower in %BF and higher in all other variables compared with women. Individual variability was notable (ADP1-ADP2). The range of individual intertrial differences were larger for women than men, respectively, for Db (-0.0096-0.0045 g/cc; -0.0019-0.0054 g/cc), TGV (-0.623-1.325 L; -0.584-0.378 L), Vb (-0.249-2.10 L; -0.234-0.397 L), and %BF (-2.1-4.4%; -0.2-0.9%). When assessing body composition of women via ADP or using Db from ADP in a multicomponent model, at least two trials with measured TGV should be performed and the average of the values recorded and reported.
Design integration and noise studies for jet STOL aircraft. Volume 1: Program summary
NASA Technical Reports Server (NTRS)
Okeefe, V. O.; Kelley, G. S.
1972-01-01
This program was undertaken to develop, through analysis, design, experimental static testing, wind tunnel testing, and design integration studies, an augmentor wing jet flap configuration for a jet STOL transport aircraft having maximum propulsion and aerodynamic performance with minimum noise generation. The program had three basic elements: (1) static testing of a scale wing section to demonstrate augmentor performance and noise characteristics; (2) two-dimensional wind tunnel testing to determine flight speed effects on performance; and (3) system design and evaluation which integrated the augmentor information obtained into a complete system and ensured that the design was compatible with the requirements for a large STOL transport having a 500-ft sideline noise of 95 PNdB or less. This objective has been achieved.
Pilot expertise and hippocampal size: associations with longitudinal flight simulator performance.
Adamson, Maheen M; Bayley, Peter J; Scanlon, Blake K; Farrell, Michelle E; Hernandez, Beatriz; Weiner, Michael W; Yesavage, Jerome A; Taylor, Joy L
2012-09-01
Previous research suggests that the size of the hippocampus can vary in response to intensive training (e.g., during the acquisition of expert knowledge). However, the role of the hippocampus in maintenance of skilled performance is not well understood. The Stanford/Veterans Affairs Aviation MRI Study offers a unique opportunity to observe the interaction of brain structure and multiple levels of expertise on longitudinal flight simulator performance. The current study examined the relationship between hippocampal volume and three levels of aviation expertise, defined by pilot proficiency ratings issued by the U.S. Federal Aviation Administration (11). At 3 annual time points, 60 pilots who varied in their level of aviation expertise (ages ranging from 45 to 69 yr) were tested. At baseline, higher expertise was associated with better flight simulator performance, but not with hippocampal volume. Longitudinally, there was an Expertise x Hippocampal volume interaction, in the direction that a larger hippocampus was associated with better performance at higher levels of expertise. These results are consistent with the notion that expertise in a cognitively demanding domain involves the interplay of acquired knowledge ('mental schemas') and basic hippocampal-dependent processes.
Effect of carbohydrate composition on fluid balance, gastric emptying, and exercise performance.
Cole, K J; Grandjean, P W; Sobszak, R J; Mitchell, J B
1993-12-01
This study examined the effects of serial feedings of different carbohydrate (CHO) solutions on plasma volume, gastric emptying (GE), and performance during prolonged cycling exercise. Solutions containing 6 g% glucose-sucrose (CHO-6GS), 8.3 g% high fructose corn syrup (CHO-8HF), 6.3 g% high fructose corn syrup + 2 g% glucose polymer (CHO-8HP), and a water placebo (WP) were compared. Ten trained male cyclists performed four cycling trials consisting of 105 min at 70% VO2max followed by a 15-min all-out, self-paced performance ride. Every 15 min the men consumed one of the four test solutions. Blood samples were taken before, during, and after exercise to determine blood glucose and plasma volume changes. There were no significant differences in performance, GE, or plasma volume changes between trials. Blood glucose was significantly elevated at the 105-min time-point in all CHO trials when compared to WP. The CHO-8HF and CHO-8HP drinks resulted in a significantly higher delivery of CHO to the intestine. Higher rates of CHO oxidation during the steady-state ride were observed only with the CHO-6GS drink.
Final Report, Volume 2, The Development of Qualification Standards for Cast Duplex Stainless Steel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Russell, Steven, W.; Lundin, Carl, W.
2005-09-30
The scope of testing cast Duplex Stainless Steel (DSS) required testing to several ASTM specifications, while formulating and conducting industry round robin tests to verify and study the reproducibility of the results. ASTM E562 (Standard Test Method for Determining Volume Fraction by Systematic manual Point Count) and ASTM A923 (Standard Test Methods for Detecting Detrimental Intermetallic Phase in Wrought Duplex Austenitic/Ferritic Stainless Steels) were the specifications utilized in conducting this work. An ASTM E562 industry round robin, ASTM A923 applicability study, ASTM A923 industry round robin, and an ASTM A923 study of the effectiveness of existing foundry solution annealing proceduresmore » for producing cast DSS without intermetallic phases were implemented. In the ASTM E562 study, 5 samples were extracted from various cast austenitic and DSS in order to have varying amounts of ferrite. Each sample was metallographically prepared by UT and sent to each of 8 participants for volume fraction of ferrite measurements. Volume fraction of ferrite was measured using manual point count per ASTM E562. FN was measured from the Feritescope® and converted to volume fraction of ferrite. Results indicate that ASTM E562 is applicable to DSS and the results have excellent lab-to-lab reproducibility. Also, volume fraction of ferrite conversions from the FN measured by the Feritescope® were similar to volume fraction of ferrite measured per ASTM E562. In the ASTM A923 applicability to cast DSS study, 8 different heat treatments were performed on 3 lots of ASTM A890-4A (CD3MN) castings and 1 lot of 2205 wrought DSS. The heat treatments were selected to produce a wide range of cooling rates and hold times in order to study the suitability of ASTM A923 to the response of varying amounts on intermetallic phases [117]. The test parameters were identical to those used to develop ASTM A923 for wrought DSS. Charpy V-notch impact samples were extracted from the castings and wrought DSS and tested per ASTM A923 method B (Charpy impact test). Method A (sodium hydroxide etch test) was performed on one half of a fractured Charpy V-notch impact sample and Method C (ferric chloride corrosion weight loss test) was performed on another half. Test results for the three cast lots and one wrought lot indicate that ASTM A923 is relevant for detecting intermetallic phases in cast DSS. In the ASTM A923 round robin study, five laboratories conducted ASTM A923 Methods A & C on cast DSS material and the lab-to-lab reproducibility of the data was determined. Two groups of samples were sent to the participants. Group 1 samples were tested per ASTM A923 Method A, group 2 samples were tested by ASTM A923 Method C. Testing procedures for this round robin study were identical to those used in the ASTM A923 applicability study. Results from this round robin indicate that there is excellent lab-to-lab reproducibility of ASTM A923 with respect to cast DSS and that ASTM A923 could be expanded to cover both wrought and cast DSS. In the ASTM A923 study of the effectiveness of existing foundry solution annealing procedures for producing cast DSS without intermetallic phases, Ten heats of ASTM A890-4A (CD3MN) in the foundry solution annealed condition were tested per ASTM A923 Methods A, B, & C. Testing of these materials per ASTM A923 was used to determine if the foundry solution anneal procedures were adequate to completely eliminate any intermetallic phases, which may have precipitated during the casting and subsequent heat treatment processes. All heats showed no sign of intermetallic phase per Method A, passed minimum Charpy impact energy requirements per Method B (> 40 ft-lbs @ -40°C (-40°F)), and showed negligible weight loss per Method C (< 10 mdd). These results indicate that the solution annealing procedure used by foundries is adequate to produce a product free from intermetallic phases.« less
Final Report, Volume 2, The Development of Qualification Standards for Cast Duplex Stainless Steel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Russell, Steven, W.; Lundin, Carl, D.
2005-09-30
The scope of testing cast Duplex Stainless Steel (DSS) required testing to several ASTM specifications, while formulating and conducting industry round robin tests to verify and study the reproducibility of the results. ASTM E562 (Standard Test Method for Determining Volume Fraction by Systematic manual Point Count) and ASTM A923 (Standard Test Methods for Detecting Detrimental Intermetallic Phase in Wrought Duplex Austenitic/Ferritic Stainless Steels) were the specifications utilized in conducting this work. An ASTM E562 industry round robin, ASTM A923 applicability study, ASTM A923 industry round robin, and an ASTM A923 study of the effectiveness of existing foundry solution annealing proceduresmore » for producing cast DSS without intermetallic phases were implemented. In the ASTM E562 study, 5 samples were extracted from various cast austenitic and DSS in order to have varying amounts of ferrite. Each sample was metallographically prepared by UT and sent to each of 8 participants for volume fraction of ferrite measurements. Volume fraction of ferrite was measured using manual point count per ASTM E562. FN was measured from the Feritescope{reg_sign} and converted to volume fraction of ferrite. Results indicate that ASTM E562 is applicable to DSS and the results have excellent lab-to-lab reproducibility. Also, volume fraction of ferrite conversions from the FN measured by the Feritescope{reg_sign} were similar to volume fraction of ferrite measured per ASTM E562. In the ASTM A923 applicability to cast DSS study, 8 different heat treatments were performed on 3 lots of ASTM A890-4A (CD3MN) castings and 1 lot of 2205 wrought DSS. The heat treatments were selected to produce a wide range of cooling rates and hold times in order to study the suitability of ASTM A923 to the response of varying amounts on intermetallic phases [117]. The test parameters were identical to those used to develop ASTM A923 for wrought DSS. Charpy V-notch impact samples were extracted from the castings and wrought DSS and tested per ASTM A923 method B (Charpy impact test). Method A (sodium hydroxide etch test) was performed on one half of a fractured Charpy V-notch impact sample and Method C (ferric chloride corrosion weight loss test) was performed on another half. Test results for the three cast lots and one wrought lot indicate that ASTM A923 is relevant for detecting intermetallic phases in cast DSS. In the ASTM A923 round robin study, five laboratories conducted ASTM A923 Methods A & C on cast DSS material and the lab-to-lab reproducibility of the data was determined. Two groups of samples were sent to the participants. Group 1 samples were tested per ASTM A923 Method A, group 2 samples were tested by ASTM A923 Method C. Testing procedures for this round robin study were identical to those used in the ASTM A923 applicability study. Results from this round robin indicate that there is excellent lab-to-lab reproducibility of ASTM A923 with respect to cast DSS and that ASTM A923 could be expanded to cover both wrought and cast DSS. In the ASTM A923 study of the effectiveness of existing foundry solution annealing procedures for producing cast DSS without intermetallic phases, Ten heats of ASTM A890-4A (CD3MN) in the foundry solution annealed condition were tested per ASTM A923 Methods A, B, & C. Testing of these materials per ASTM A923 was used to determine if the foundry solution anneal procedures were adequate to completely eliminate any intermetallic phases, which may have precipitated during the casting and subsequent heat treatment processes. All heats showed no sign of intermetallic phase per Method A, passed minimum Charpy impact energy requirements per Method B (> 40 ft-lbs {at} -40 C (-40 F)), and showed negligible weight loss per Method C (< 10 mdd). These results indicate that the solution annealing procedure used by foundries is adequate to produce a product free from intermetallic phases.« less
Cai, Wenli; Lee, June-Goo; Fikry, Karim; Yoshida, Hiroyuki; Novelline, Robert; de Moya, Marc
2013-01-01
It is commonly believed that the size of a pneumothorax is an important determinant of treatment decision, in particular regarding whether chest tube drainage (CTD) is required. However, the volumetric quantification of pneumothoraces has not routinely been performed in clinics. In this paper, we introduced an automated computer-aided volumetry (CAV) scheme for quantification of volume of pneumothoraces in chest multi-detect CT (MDCT) images. Moreover, we investigated the impact of accurate volume of pneumothoraces in the improvement of the performance in decision-making regarding CTD in the management of traumatic pneumothoraces. For this purpose, an occurrence frequency map was calculated for quantitative analysis of the importance of each clinical parameter in the decision-making regarding CTD by a computer simulation of decision-making using a genetic algorithm (GA) and a support vector machine (SVM). A total of 14 clinical parameters, including volume of pneumothorax calculated by our CAV scheme, was collected as parameters available for decision-making. The results showed that volume was the dominant parameter in decision-making regarding CTD, with an occurrence frequency value of 1.00. The results also indicated that the inclusion of volume provided the best performance that was statistically significant compared to the other tests in which volume was excluded from the clinical parameters. This study provides the scientific evidence for the application of CAV scheme in MDCT volumetric quantification of pneumothoraces in the management of clinically stable chest trauma patients with traumatic pneumothorax. PMID:22560899
Evaluation of usefulness of Skylab EREP S-190 and S-192 imagery in multistage forest surveys
NASA Technical Reports Server (NTRS)
Langley, P. G. (Principal Investigator)
1973-01-01
The author has identified the following significant results. A unique digital timber volume estimation system with digital data for two ERTS-1 MSS bands was tested. The system was tested on a 64-square mile area in Northern California's Trinity Alps. The outcome of a systematic experiment in which possible combinations of the two bands (MSS 5 and 7) were tried, showed than an estimated gain in precision of 50% can be obtained in a multistage sampling design. Especially the difference between the two bands proved to be of major importance for the estimation of biomass in the form of timber volume. Identical tests as the one performed will be conducted with various S-192 bands when the digital data become available.
Code of Federal Regulations, 2011 CFR
2011-07-01
... per million dry volume absolute value of the mean difference between the method and the continuous... activities (including, as applicable, calibration checks and required zero and span adjustments). Any such...
Vermetten, Eric; Vythilingam, Meena; Southwick, Steven M.; Charney, Dennis S.; Bremner, J. Douglas
2011-01-01
Background Animal studies have shown that stress is associated with damage to the hippocampus, inhibition of neurogenesis, and deficits in hippocampal-based memory dysfunction. Studies in patients with posttraumatic stress disorder (PTSD) found deficits in hippocampal-based declarative verbal memory and smaller hippocampal volume, as measured with magnetic resonance imaging (MRI). Recent preclinical evidence has shown that selective serotonin reuptake inhibitors promote neurogenesis and reverse the effects of stress on hippocampal atrophy. This study assessed the effects of long-term treatment with paroxetine on hippocampal volume and declarative memory performance in PTSD. Methods Declarative memory was assessed with the Wechsler Memory Scale–Revised and Selective Reminding Test before and after 9–12 months of treatment with paroxetine in PTSD. Hippocampal volume was measured with MRI. Of the 28 patients who started the protocol, 23 completed the full course of treatment and neuropsychological testing. Twenty patients were able to complete MRI imaging. Results Patients with PTSD showed a significant improvement in PTSD symptoms with treatment. Treatment resulted in significant improvements in verbal declarative memory and a 4.6% increase in mean hippocampal volume. Conclusions These findings suggest that long-term treatment with paroxetine is associated with improvement of verbal declarative memory deficits and an increase in hippocampal volume in PTSD. PMID:14512209
Respiratory adaptations in different types of sport.
Lazovic, B; Mazic, S; Suzic-Lazic, J; Djelic, M; Djordjevic-Saranovic, S; Durmic, T; Zikic, D; Zugic, V
2015-06-01
Recent studies demonstrated that current European Respiratory Society/American Thoracic Society spirometric reference equations, used in general population, may not be applicable in population of elite athletes. Althought it is well known that physical activity may affect lung volumes, the effect of sporting activity on pulmonary function testing indices was never examined. The aim of this study was to examine the differences in functional respiratory parameters in various types of sports by measuring lung volumes and to extend the existing factors as well as sport disciplines which affect respiratory function the most. A total of 1639 elite male athletes, aged 18-35 years were divided in 4 groups according to the predominant characteristics of training: skill, power, mixed and endurance athletes. They performed basic anthropometric measurements and spirometry. Groups were compared, and Pearson's simple correlation was performed to test the relation between anthropometric and spirometric characteristics of athletes. All anthropometric characteristics significantly differed among groups and correlate with respiratory parameters. The highest correlation was found for body height and weight. Sports participation is associated with respiratory adaptation, and the extent of adaptation depends on type of activity. Endurance sports athletes have higher lung volumes in comparison with skill, mixed and power group of sport.
Blade system design studies volume II : preliminary blade designs and recommended test matrix.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Griffin, Dayton A.
2004-06-01
As part of the U.S. Department of Energy's Wind Partnerships for Advanced Component Technologies (WindPACT) program, Global Energy Concepts, LLC is performing a Blade System Design Study (BSDS) concerning innovations in materials, processes and structural configurations for application to wind turbine blades in the multi-megawatt range. The BSDS Volume I project report addresses issues and constraints identified to scaling conventional blade designs to the megawatt size range, and evaluated candidate materials, manufacturing and design innovations for overcoming and improving large blade economics. The current report (Volume II), presents additional discussion of materials and manufacturing issues for large blades, including amore » summary of current trends in commercial blade manufacturing. Specifications are then developed to guide the preliminary design of MW-scale blades. Using preliminary design calculations for a 3.0 MW blade, parametric analyses are performed to quantify the potential benefits in stiffness and decreased gravity loading by replacement of a baseline fiberglass spar with carbon-fiberglass hybrid material. Complete preliminary designs are then presented for 3.0 MW and 5.0 MW blades that incorporate fiberglass-to-carbon transitions at mid-span. Based on analysis of these designs, technical issues are identified and discussed. Finally, recommendations are made for composites testing under Part I1 of the BSDS, and the initial planned test matrix for that program is presented.« less
Estimation of gas and tissue lung volumes by MRI: functional approach of lung imaging.
Qanadli, S D; Orvoen-Frija, E; Lacombe, P; Di Paola, R; Bittoun, J; Frija, G
1999-01-01
The purpose of this work was to assess the accuracy of MRI for the determination of lung gas and tissue volumes. Fifteen healthy subjects underwent MRI of the thorax and pulmonary function tests [vital capacity (VC) and total lung capacity (TLC)] in the supine position. MR examinations were performed at inspiration and expiration. Lung volumes were measured by a previously validated technique on phantoms. Both individual and total lung volumes and capacities were calculated. MRI total vital capacity (VC(MRI)) was compared with spirometric vital capacity (VC(SP)). Capacities were correlated to lung volumes. Tissue volume (V(T)) was estimated as the difference between the total lung volume at full inspiration and the TLC. No significant difference was seen between VC(MRI) and VC(SP). Individual capacities were well correlated (r = 0.9) to static volume at full inspiration. The V(T) was estimated to be 836+/-393 ml. This preliminary study demonstrates that MRI can accurately estimate lung gas and tissue volumes. The proposed approach appears well suited for functional imaging of the lung.
NASA Astrophysics Data System (ADS)
Tiedeman, C. R.; Barrash, W.; Thrash, C. J.; Patterson, J.; Johnson, C. D.
2016-12-01
Hydraulic tomography was performed in a 100 m2 by 20 m thick volume of contaminated fractured mudstones at the former Naval Air Warfare Center (NAWC) in the Newark Basin, New Jersey, with the objective of estimating the detailed distribution of hydraulic conductivity (K). Characterizing the fine-scale K variability is important for designing effective remediation strategies in complex geologic settings such as fractured rock. In the tomography experiment, packers isolated two to six intervals in each of seven boreholes in the volume of investigation, and fiber-optic pressure transducers enabled collection of high-resolution drawdown observations. A hydraulic tomography dataset was obtained by conducting multiple aquifer tests in which a given isolated well interval was pumped and drawdown was monitored in all other intervals. The collective data from all tests display a wide range of behavior indicative of highly heterogeneous K within the tested volume, such as: drawdown curves for different intervals crossing one another on drawdown-time plots; unique drawdown curve shapes for certain intervals; and intervals with negligible drawdown adjacent to intervals with large drawdown. Tomographic inversion of data from 15 tests conducted in the first field season focused on estimating the K distribution at a scale of 1 m3 over approximately 25% of the investigated volume, where observation density was greatest. The estimated K field is consistent with prior geologic, geophysical, and hydraulic information, including: highly variable K within bedding-plane-parting fractures that are the primary flow and transport paths at NAWC, connected high-K features perpendicular to bedding, and a spatially heterogeneous distribution of low-K rock matrix and closed fractures. Subsequent tomographic testing was conducted in the second field season, with the region of high observation density expanded to cover a greater volume of the wellfield.
75 FR 29605 - Clean Alternative Fuel Vehicle and Engine Conversions
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-26
... Small Volume Manufacturers and Small Volume Test Groups 1. Definition of Small Volume Manufacturers, Small Volume Test Groups, and Small Volume Engine Families a. Light-Duty and Heavy-Duty Complete... and Engines 2. Test Groups, Engine Families, and Evaporative Families a. Test Groups for Light-Duty...
Tip aerodynamics and acoustics test: A report and data survey
NASA Technical Reports Server (NTRS)
Cross, Jeffrey L.; Watts, Michael E.
1988-01-01
In a continuing effort to understand helicopter rotor tip aerodynamics and acoustics, a flight test was conducted by NASA Ames Research Center. The test was performed using the NASA White Cobra and a set of highly instrumented blades. All aspects of the flight test instrumentation and test procedures are explained. Additionally, complete data sets for selected test points are presented and analyzed. Because of the high volume of data acquired, only selected data points are presented. However, access to the entire data set is available to the researcher on request.
Kim, Youngwoo; Ge, Yinghui; Tao, Cheng; Zhu, Jianbing; Chapman, Arlene B.; Torres, Vicente E.; Yu, Alan S.L.; Mrug, Michal; Bennett, William M.; Flessner, Michael F.; Landsittel, Doug P.
2016-01-01
Background and objectives Our study developed a fully automated method for segmentation and volumetric measurements of kidneys from magnetic resonance images in patients with autosomal dominant polycystic kidney disease and assessed the performance of the automated method with the reference manual segmentation method. Design, setting, participants, & measurements Study patients were selected from the Consortium for Radiologic Imaging Studies of Polycystic Kidney Disease. At the enrollment of the Consortium for Radiologic Imaging Studies of Polycystic Kidney Disease Study in 2000, patients with autosomal dominant polycystic kidney disease were between 15 and 46 years of age with relatively preserved GFRs. Our fully automated segmentation method was on the basis of a spatial prior probability map of the location of kidneys in abdominal magnetic resonance images and regional mapping with total variation regularization and propagated shape constraints that were formulated into a level set framework. T2–weighted magnetic resonance image sets of 120 kidneys were selected from 60 patients with autosomal dominant polycystic kidney disease and divided into the training and test datasets. The performance of the automated method in reference to the manual method was assessed by means of two metrics: Dice similarity coefficient and intraclass correlation coefficient of segmented kidney volume. The training and test sets were swapped for crossvalidation and reanalyzed. Results Successful segmentation of kidneys was performed with the automated method in all test patients. The segmented kidney volumes ranged from 177.2 to 2634 ml (mean, 885.4±569.7 ml). The mean Dice similarity coefficient ±SD between the automated and manual methods was 0.88±0.08. The mean correlation coefficient between the two segmentation methods for the segmented volume measurements was 0.97 (P<0.001 for each crossvalidation set). The results from the crossvalidation sets were highly comparable. Conclusions We have developed a fully automated method for segmentation of kidneys from abdominal magnetic resonance images in patients with autosomal dominant polycystic kidney disease with varying kidney volumes. The performance of the automated method was in good agreement with that of manual method. PMID:26797708
Kim, Youngwoo; Ge, Yinghui; Tao, Cheng; Zhu, Jianbing; Chapman, Arlene B; Torres, Vicente E; Yu, Alan S L; Mrug, Michal; Bennett, William M; Flessner, Michael F; Landsittel, Doug P; Bae, Kyongtae T
2016-04-07
Our study developed a fully automated method for segmentation and volumetric measurements of kidneys from magnetic resonance images in patients with autosomal dominant polycystic kidney disease and assessed the performance of the automated method with the reference manual segmentation method. Study patients were selected from the Consortium for Radiologic Imaging Studies of Polycystic Kidney Disease. At the enrollment of the Consortium for Radiologic Imaging Studies of Polycystic Kidney Disease Study in 2000, patients with autosomal dominant polycystic kidney disease were between 15 and 46 years of age with relatively preserved GFRs. Our fully automated segmentation method was on the basis of a spatial prior probability map of the location of kidneys in abdominal magnetic resonance images and regional mapping with total variation regularization and propagated shape constraints that were formulated into a level set framework. T2-weighted magnetic resonance image sets of 120 kidneys were selected from 60 patients with autosomal dominant polycystic kidney disease and divided into the training and test datasets. The performance of the automated method in reference to the manual method was assessed by means of two metrics: Dice similarity coefficient and intraclass correlation coefficient of segmented kidney volume. The training and test sets were swapped for crossvalidation and reanalyzed. Successful segmentation of kidneys was performed with the automated method in all test patients. The segmented kidney volumes ranged from 177.2 to 2634 ml (mean, 885.4±569.7 ml). The mean Dice similarity coefficient ±SD between the automated and manual methods was 0.88±0.08. The mean correlation coefficient between the two segmentation methods for the segmented volume measurements was 0.97 (P<0.001 for each crossvalidation set). The results from the crossvalidation sets were highly comparable. We have developed a fully automated method for segmentation of kidneys from abdominal magnetic resonance images in patients with autosomal dominant polycystic kidney disease with varying kidney volumes. The performance of the automated method was in good agreement with that of manual method. Copyright © 2016 by the American Society of Nephrology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wetzel, Kyle K.; Hermann, Thomas M.; Locke, James
2005-11-01
Anisotropic carbon/glass hybrid composite laminates have been fabricated, tested, and analyzed. The laminates have been fabricated using vacuum-assisted resin transfer molding (VARTM). Five fiber complexes and a two-part epoxy resin system have been used in the study to fabricate panels of twenty different laminate constructions. These panels have been subjected to physical testing to measure density, fiber volume fraction, and void fraction. Coupons machined from these panels have also been subjected to mechanical testing to measure elastic properties and strength of the laminates using tensile, compressive, transverse tensile, and in-plane shear tests. Interlaminar shear strength has also been measured. Out-of-planemore » displacement, axial strain, transverse strain, and inplane shear strain have also been measured using photogrammetry data obtained during edgewise compression tests. The test data have been reduced to characterize the elastic properties and strength of the laminates. Constraints imposed by test fixtures might be expected to affect measurements of the moduli of anisotropic materials; classical lamination theory has been used to assess the magnitude of such effects and correct the experimental data for the same. The tensile moduli generally correlate well with experiment without correction and indicate that factors other than end constraints dominate. The results suggest that shear moduli of the anisotropic materials are affected by end constraints. Classical lamination theory has also been used to characterize the level of extension-shear coupling in the anisotropic laminates. Three factors affecting the coupling have been examined: the volume fraction of unbalanced off-axis layers, the angle of the off-axis layers, and the composition of the fibers (i.e., carbon or glass) used as the axial reinforcement. The results indicate that extension/shear coupling is maximized with the least loss in axial tensile stiffness by using carbon fibers oriented 15{sup o} from the long axis for approximately two-thirds of the laminate volume (discounting skin layers), with reinforcing carbon fibers oriented axially comprising the remaining one-third of the volume. Finite element analysis of each laminate has been performed to examine first ply failure. Three failure criteria--maximum stress, maximum strain, and Tsai-Wu--have been compared. Failure predicted by all three criteria proves generally conservative, with the stress-based criteria the most conservative. For laminates that respond nonlinearly to loading, large error is observed in the prediction of failure using maximum strain as the criterion. This report documents the methods and results in two volumes. Volume 1 contains descriptions of the laminates, their fabrication and testing, the methods of analysis, the results, and the conclusions and recommendations. Volume 2 contains a comprehensive summary of the individual test results for all laminates.« less
Effects of Early Life Stress on Depression, Cognitive Performance, and Brain Morphology
Saleh, Ayman; Potter, Guy G.; McQuoid, Douglas R.; Boyd, Brian; Turner, Rachel; MacFall, James R; Taylor, Warren D.
2016-01-01
Background Childhood early life stress (ELS) increases risk of adulthood Major Depressive Disorder (MDD) and is associated with altered brain structure and function. It is unclear whether specific ELSs affect depression risk, cognitive function and brain structure. Methods This cross-sectional study included 64 antidepressant-free depressed and 65 never depressed individuals. Both groups reported a range of ELSs on the Early Life Stress Questionnaire, completed neuropsychological testing and 3T MRI. Neuropsychological testing assessed domains of episodic memory, working memory, processing speed and executive function. MRI measures included cortical thickness and regional gray matter volumes, with a priori focus on cingulate cortex, orbitofrontal cortex (OFC), amygdala, caudate and hippocampus. Results Of 19 ELSs, only emotional abuse, sexual abuse and severe family conflict independently predicted adulthood MDD diagnosis. The effect of total ELS score differed between groups. Greater ELS exposure was associated with slower processing speed and smaller OFC volumes in depressed subjects, but faster speed and larger volumes in nondepressed subjects. In contrast, exposure to ELSs predictive of depression had similar effects in both diagnostic groups. Individuals reporting predictive ELSs exhibited poorer processing speed and working memory performance, smaller volumes of the lateral OFC and caudate, and decreased cortical thickness in multiple areas including the insula bilaterally. Predictive ELS exposure was also associated with smaller left hippocampal volume in depressed subjects. Conclusion Findings suggest an association between childhood trauma exposure and adulthood cognitive function and brain structure. These relationships appear to differ between individuals who do and do not develop depression. PMID:27682320
Navarro-Ramirez, Rodrigo; Berlin, Connor; Lang, Gernot; Hussain, Ibrahim; Janssen, Insa; Sloan, Stephen; Askin, Gulce; Avila, Mauricio J; Zubkov, Micaella; Härtl, Roger
2018-01-01
Two-dimensional radiographic methods have been proposed to evaluate the radiographic outcome after indirect decompression through extreme lateral interbody fusion (XLIF). However, the assessment of neural decompression in a single plane may underestimate the effect of indirect decompression on central canal and foraminal volumes. The present study aimed to assess the reliability and consistency of a novel 3-dimensional radiographic method that assesses neural decompression by volumetric analysis using a new generation of intraoperative fan-beam computed tomography scanner in patients undergoing XLIF. Prospectively collected data from 7 patients (9 levels) undergoing XLIF was retrospectively analyzed. Three independent, blind raters using imaging analysis software performed volumetric measurements pre- and postoperatively to determine central canal and foraminal volumes. Intrarater and Interrater reliability tests were performed to assess the reliability of this novel volumetric method. The interrater reliability between the three raters ranged from 0.800 to 0.952, P < 0.0001. The test-retest analysis on a randomly selected subset of three patients showed good to excellent internal reliability (range of 0.78-1.00) for all 3 raters. There was a significant increase in mean volume ≈20% for right foramen, left foramen, and central canal volumes postoperatively (P = 0.0472; P = 0.0066; P = 0.0003, respectively). Here we demonstrate a new volumetric analysis technique that is feasible, reliable, and reproducible amongst independent raters for central canal and foraminal volumes in the lumbar spine using an intraoperative computed tomography scanner. Copyright © 2017. Published by Elsevier Inc.
NASA Technical Reports Server (NTRS)
1982-01-01
Tests to verify the as-designed performance of all circuits within the thematic mapper electronics module unit are described. Specifically, the tests involved the evaluation of the scan line corrector driver, shutter drivers function, cal lamp controller function, post amplifier function, command decoder verification unit, and the temperature and actuator controllers function.
NASA Technical Reports Server (NTRS)
1974-01-01
The technical aspects of the Skylab-Orbital Workshop are discussed. Original concepts, goals, design philosophy, hardware, and testing are reported. The final flight configuration, overall test program, and mission performance are analyzed. The systems which are examined are: (1) the structural system, (2) the meteoroid shield systems, and (3) the environmental/thermal control subsystem.
Song, Weimin; Yin, Jian
2016-01-01
Fiber reinforcement is an important method to enhance the performance of concrete. In this study, the compressive test and impact test were conducted, and then the hybrid effect between steel fiber (SF) and carbon fiber (CF) was evaluated by employing the hybrid effect index. Compressive toughness and impact toughness of steel fiber reinforced concrete (SFRC), carbon fiber reinforced concrete (CFRC) and hybrid fiber reinforced concrete (HFRC) were explored at steel fiber volume fraction 0.5%, 1%, 1.5% and carbon fiber 0.1%, 0.2%, 0.3%. Results showed that the addition of steel fiber and carbon fiber can increase the compressive strength. SF, CF and the hybridization between them could increase the compressive toughness significantly. The impact test results showed that as the volume of fiber increased, the impact number of the first visible crack and the ultimate failure also increased. The improvement of toughness mainly lay in improving the crack resistance after the first crack. Based on the test results, the positive hybrid effect of steel fiber and carbon fiber existed in hybrid fiber reinforced concrete. The relationship between the compressive toughness and impact toughness was also explored. PMID:28773824
Song, Weimin; Yin, Jian
2016-08-18
Fiber reinforcement is an important method to enhance the performance of concrete. In this study, the compressive test and impact test were conducted, and then the hybrid effect between steel fiber (SF) and carbon fiber (CF) was evaluated by employing the hybrid effect index. Compressive toughness and impact toughness of steel fiber reinforced concrete (SFRC), carbon fiber reinforced concrete (CFRC) and hybrid fiber reinforced concrete (HFRC) were explored at steel fiber volume fraction 0.5%, 1%, 1.5% and carbon fiber 0.1%, 0.2%, 0.3%. Results showed that the addition of steel fiber and carbon fiber can increase the compressive strength. SF, CF and the hybridization between them could increase the compressive toughness significantly. The impact test results showed that as the volume of fiber increased, the impact number of the first visible crack and the ultimate failure also increased. The improvement of toughness mainly lay in improving the crack resistance after the first crack. Based on the test results, the positive hybrid effect of steel fiber and carbon fiber existed in hybrid fiber reinforced concrete. The relationship between the compressive toughness and impact toughness was also explored.
2013-01-01
Background Almost nothing is known about the medical aspects of runners doing a transcontinental ultramarathon over several weeks. The results of differentiated measurements of changes in body composition during the Transeurope Footrace 2009 using a mobile whole body magnetic resonance (MR) imager are presented and the proposed influence of visceral and somatic adipose and lean tissue distribution on performance tested. Methods 22 participants were randomly selected for the repeated MR measurements (intervals: 800 km) with a 1.5 Tesla MR scanner mounted on a mobile unit during the 64-stage 4,486 km ultramarathon. A standardized and validated MRI protocol was used: T1 weighted turbo spin echo sequence, echo time 12 ms, repetition time 490 ms, slice thickness 10 mm, slice distance 10 mm (breath holding examinations). For topographic tissue segmentation and mapping a modified fuzzy c-means algorithm was used. A semi-automatic post-processing of whole body MRI data sets allows reliable analysis of the following body tissue compartments: Total body volume (TV), total somatic (TSV) and total visceral volume (TVV), total adipose (TAT) and total lean tissue (TLT), somatic (SLT) and visceral lean tissue (VLT), somatic (SAT) and visceral adipose tissue (VAT) and somatic adipose soft tissue (SAST). Specific volume changes were tested on significance. Tests on difference and relationship regarding prerace and race performance and non-finishing were done using statistical software SPSS. Results Total, somatic and visceral volumes showed a significant decrease throughout the race. Adipose tissue showed a significant decrease compared to the start at all measurement times for TAT, SAST and VAT. Lean adipose tissues decreased until the end of the race, but not significantly. The mean relative volume changes of the different tissue compartments at the last measurement compared to the start were: TV −9.5% (SE 1.5%), TSV −9.4% (SE 1.5%), TVV −10.0% (SE 1.4%), TAT −41.3% (SE 2.3%), SAST −48.7% (SE 2.8%), VAT −64.5% (SE 4.6%), intraabdominal adipose tissue (IAAT) −67.3% (SE 4.3%), mediastinal adopose tissue (MAT) −41.5% (SE 7.1%), TLT −1.2% (SE 1.0%), SLT −1.4% (SE 1.1%). Before the start and during the early phase of the Transeurope Footrace 2009, the non-finisher group had a significantly higher percentage volume of TVV, TAT, SAST and VAT compared to the finisher group. VAT correlates significantly with prerace training volume and intensity one year before the race and with 50 km- and 24 hour-race records. Neither prerace body composition nor specific tissue compartment volume changes showed a significant relationship to performance in the last two thirds of the Transeurope Footrace 2009. Conclusions With this mobile MRI field study the complex changes in body composition during a multistage ultramarathon could be demonstrated in detail in a new and differentiated way. Participants lost more than half of their adipose tissue. Even lean tissue volume (mainly skeletal muscle tissue) decreased due to the unpreventable chronic negative energy balance during the race. VAT has the fastest and highest decrease compared to SAST and lean tissue compartments during the race. It seems to be the most sensitive morphometric parameter regarding the risk of non-finishing a transcontinental footrace and shows a direct relationship to prerace-performance. However, body volume or body mass and, therefore, fat volume has no correlation with total race performances of ultra-athletes finishing a 4,500 km multistage race. PMID:23657091
Back to the future: estimating pre-injury brain volume in patients with traumatic brain injury.
Ross, David E; Ochs, Alfred L; D Zannoni, Megan; Seabaugh, Jan M
2014-11-15
A recent meta-analysis by Hedman et al. allows for accurate estimation of brain volume changes throughout the life span. Additionally, Tate et al. showed that intracranial volume at a later point in life can be used to estimate reliably brain volume at an earlier point in life. These advancements were combined to create a model which allowed the estimation of brain volume just prior to injury in a group of patients with mild or moderate traumatic brain injury (TBI). This volume estimation model was used in combination with actual measurements of brain volume to test hypotheses about progressive brain volume changes in the patients. Twenty six patients with mild or moderate TBI were compared to 20 normal control subjects. NeuroQuant® was used to measure brain MRI volume. Brain volume after the injury (from MRI scans performed at t1 and t2) was compared to brain volume just before the injury (volume estimation at t0) using longitudinal designs. Groups were compared with respect to volume changes in whole brain parenchyma (WBP) and its 3 major subdivisions: cortical gray matter (GM), cerebral white matter (CWM) and subcortical nuclei+infratentorial regions (SCN+IFT). Using the normal control data, the volume estimation model was tested by comparing measured brain volume to estimated brain volume; reliability ranged from good to excellent. During the initial phase after injury (t0-t1), the TBI patients had abnormally rapid atrophy of WBP and CWM, and abnormally rapid enlargement of SCN+IFT. Rates of volume change during t0-t1 correlated with cross-sectional measures of volume change at t1, supporting the internal reliability of the volume estimation model. A logistic regression analysis using the volume change data produced a function which perfectly predicted group membership (TBI patients vs. normal control subjects). During the first few months after injury, patients with mild or moderate TBI have rapid atrophy of WBP and CWM, and rapid enlargement of SCN+IFT. The magnitude and pattern of the changes in volume may allow for the eventual development of diagnostic tools based on the volume estimation approach. Copyright © 2014 Elsevier Inc. All rights reserved.
Acoustic measurements of a full-scale rotor with four tip shapes. Volume 2: Appendices C, D, E and F
NASA Technical Reports Server (NTRS)
Mosher, M.
1984-01-01
A full scale helicopter with four different blade tip geometries is tested in a 40- by 80-foot wind tunnel. Performance, loads, and noise are measured. The four tip shapes tested were rectangular, tapered, swept, and swept/tapered. The noise data include measurements of the sound pressure levels in decibels dB, decibels adjusted dBA, and tone-corrected PNdB, for all of the conditions tested. Also included are the detailed measurements, 1/3 octave spectra and time histories for some selected data, and plots of dBA as function of test condition. Some performance measurements are included to aid interpretation of the noise data.
NASA Technical Reports Server (NTRS)
Wisler, D. C.
1981-01-01
The core compressor exit stage study program develops rear stage blading designs that have lower losses in their endwall boundary layer regions. The test data and performance results for the best stage configuration consisting of Rotor-B running with Stator-B are described. The technical approach in this efficiency improvement program utilizes a low speed research compressor. Tests were conducted in two ways: (1) to use four identical stages of blading to obtain test data in a true multistage environment and (2) to use a single stage of blading to compare with the multistage test results. The effects of increased rotor tip clearances and circumferential groove casing treatment are evaluated.
NASA Technical Reports Server (NTRS)
1976-01-01
The performance capability of each of two precision attitude determination systems (PADS), one using a strapdown star tracker, and the other using a single-axis gimbal star tracker was measured in the laboratory under simulated orbit conditions. The primary focus of the evaluation was on the contribution to the total system accuracy by the star trackers, and the effectiveness of the software algorithms in functioning with actual sensor signals. A brief description of PADS, the laboratory test configuration and the test facility, is given along with a discussion of the data handling and display, laboratory computer programs, PADS performance evaluation programs, and the strapdown and gimbal system tests. Results are presented and discussed.
1983-12-01
tests were conducted for the Maline Creek urban study recently completed by the St. Louis District. Those tests showed that variations in the...were not performed .or expansion and contraction coefficients used in this study. However, such tests were conducted for the Maline Creek urban study...Conservation, letter to Mr. Jack Rasmussen, Chief of Planning Branch, St. -Louis District, Reference to Maline Creek Study, dated 18 June 1979. Griffin, C
Predictors of pneumothorax following endoscopic valve therapy in patients with severe emphysema.
Gompelmann, Daniela; Lim, Hyun-Ju; Eberhardt, Ralf; Gerovasili, Vasiliki; Herth, Felix Jf; Heussel, Claus Peter; Eichinger, Monika
2016-01-01
Endoscopic valve implantation is an effective treatment for patients with advanced emphysema. Despite the minimally invasive procedure, valve placement is associated with risks, the most common of which is pneumothorax. This study was designed to identify predictors of pneumothorax following endoscopic valve implantation. Preinterventional clinical measures (vital capacity, forced expiratory volume in 1 second, residual volume, total lung capacity, 6-minute walk test), qualitative computed tomography (CT) parameters (fissure integrity, blebs/bulla, subpleural nodules, pleural adhesions, partial atelectasis, fibrotic bands, emphysema type) and quantitative CT parameters (volume and low attenuation volume of the target lobe and the ipsilateral untreated lobe, target air trapping, ipsilateral lobe volume/hemithorax volume, collapsibility of the target lobe and the ipsilateral untreated lobe) were retrospectively evaluated in patients who underwent endoscopic valve placement (n=129). Regression analysis was performed to compare those who developed pneumothorax following valve therapy (n=46) with those who developed target lobe volume reduction without pneumothorax (n=83). Low attenuation volume% of ipsilateral untreated lobe (odds ratio [OR] =1.08, P=0.001), ipsilateral untreated lobe volume/hemithorax volume (OR =0.93, P=0.017), emphysema type (OR =0.26, P=0.018), pleural adhesions (OR =0.33, P=0.012) and residual volume (OR =1.58, P=0.012) were found to be significant predictors of pneumothorax. Fissure integrity (OR =1.16, P=0.075) and 6-minute walk test (OR =1.05, P=0.077) were also indicative of pneumothorax. The model including the aforementioned parameters predicted whether a patient would experience a pneumothorax 84% of the time (area under the curve =0.84). Clinical and CT parameters provide a promising tool to effectively identify patients at high risk of pneumothorax following endoscopic valve therapy.
Predictors of pneumothorax following endoscopic valve therapy in patients with severe emphysema
Gompelmann, Daniela; Lim, Hyun-ju; Eberhardt, Ralf; Gerovasili, Vasiliki; Herth, Felix JF; Heussel, Claus Peter; Eichinger, Monika
2016-01-01
Background Endoscopic valve implantation is an effective treatment for patients with advanced emphysema. Despite the minimally invasive procedure, valve placement is associated with risks, the most common of which is pneumothorax. This study was designed to identify predictors of pneumothorax following endoscopic valve implantation. Methods Preinterventional clinical measures (vital capacity, forced expiratory volume in 1 second, residual volume, total lung capacity, 6-minute walk test), qualitative computed tomography (CT) parameters (fissure integrity, blebs/bulla, subpleural nodules, pleural adhesions, partial atelectasis, fibrotic bands, emphysema type) and quantitative CT parameters (volume and low attenuation volume of the target lobe and the ipsilateral untreated lobe, target air trapping, ipsilateral lobe volume/hemithorax volume, collapsibility of the target lobe and the ipsilateral untreated lobe) were retrospectively evaluated in patients who underwent endoscopic valve placement (n=129). Regression analysis was performed to compare those who developed pneumothorax following valve therapy (n=46) with those who developed target lobe volume reduction without pneumothorax (n=83). Finding Low attenuation volume% of ipsilateral untreated lobe (odds ratio [OR] =1.08, P=0.001), ipsilateral untreated lobe volume/hemithorax volume (OR =0.93, P=0.017), emphysema type (OR =0.26, P=0.018), pleural adhesions (OR =0.33, P=0.012) and residual volume (OR =1.58, P=0.012) were found to be significant predictors of pneumothorax. Fissure integrity (OR =1.16, P=0.075) and 6-minute walk test (OR =1.05, P=0.077) were also indicative of pneumothorax. The model including the aforementioned parameters predicted whether a patient would experience a pneumothorax 84% of the time (area under the curve =0.84). Interpretation Clinical and CT parameters provide a promising tool to effectively identify patients at high risk of pneumothorax following endoscopic valve therapy. PMID:27536088
Advanced Nanoindentation Testing for Studying Strain-Rate Sensitivity and Activation Volume
NASA Astrophysics Data System (ADS)
Maier-Kiener, Verena; Durst, Karsten
2017-11-01
Nanoindentation became a versatile tool for testing local mechanical properties beyond hardness and modulus. By adapting standard nanoindentation test methods, simple protocols capable of probing thermally activated deformation processes can be accomplished. Abrupt strain-rate changes within one indentation allow determining the strain-rate dependency of hardness at various indentation depths. For probing lower strain-rates and excluding thermal drift influences, long-term creep experiments can be performed by using the dynamic contact stiffness for determining the true contact area. From both procedures hardness and strain-rate, and consequently strain-rate sensitivity and activation volume can be reliably deducted within one indentation, permitting information on the locally acting thermally activated deformation mechanism. This review will first discuss various testing protocols including possible challenges and improvements. Second, it will focus on different examples showing the direct influence of crystal structure and/or microstructure on the underlying deformation behavior in pure and highly alloyed material systems.
Automated screening of propulsion system test data by neural networks, phase 1
NASA Technical Reports Server (NTRS)
Hoyt, W. Andes; Whitehead, Bruce A.
1992-01-01
The evaluation of propulsion system test and flight performance data involves reviewing an extremely large volume of sensor data generated by each test. An automated system that screens large volumes of data and identifies propulsion system parameters which appear unusual or anomalous will increase the productivity of data analysis. Data analysts may then focus on a smaller subset of anomalous data for further evaluation of propulsion system tests. Such an automated data screening system would give NASA the benefit of a reduction in the manpower and time required to complete a propulsion system data evaluation. A phase 1 effort to develop a prototype data screening system is reported. Neural networks will detect anomalies based on nominal propulsion system data only. It appears that a reasonable goal for an operational system would be to screen out 95 pct. of the nominal data, leaving less than 5 pct. needing further analysis by human experts.
Liquid propellant thermal conditioning system test program
NASA Technical Reports Server (NTRS)
Bullard, B. R.
1972-01-01
Results are presented from more than 1500 hours of testing on a liquid hydrogen thermal conditioning unit. Test parameters included: mixer and vent flow rates; tank size; ullage volume; pressurant gas; pressurant temperature; pressure level; and heat rate. Gaseous hydrogen and helium were used as pressurants. Analytical models were developed to correlate the test data and relate the performance to that anticipated in zero gravity. Experimental and theoretical results are presented which relate the variables controlling vapor condensation at a moving interface.
Effect of Multiaxial Loading on Crack Growth. Volume 2. Compilation of Experimental Data
1978-12-01
3121 9. PERFORMING ORGANIZATION NAME AND ADORESS 10 . PROGRAM ELEMENT. PROJECT, TASK Northrop Corporation AREA & WORK UNIT NUMBERS Aircraft Group 3901...Stresses in the Center of the 2024-T351 9 Cruciform Specimen 9 Stress Distribution along the X-axis of the 10 Cruciform Specimen 10 Stress Distribution...Tensile Test Results for 7075-T7351 584 8 Tensile Test Results for 7075-T7351 600 9 Tensile Test Results for 2024-T351 610 10 Tensile Test Results for
Battalion Combat Operations Center (COC) Test. Volume II. Test Report,
1982-02-08
reveal, perhaps, that item X can perform a task faster than item-Y. A utility assessment from an experienced, knowledgeable test participant, however...can ascertain whether or not item X can better enable him to accomplish his mission than item Y. 2.4 GENeRALIZED TEST FACILITY. The capabilities of...ATHE MIX D -IX AE4SY MIXES A & C MIX A .IX D M X D IMIX C RATHER DIFFICUJLT VERY DIFFICULT ABILITY TO ABILITY TO ABILITY TO CONTROL DATA EXPLOIT DATA
Transmitted wavefront error of a volume phase holographic grating at cryogenic temperature.
Lee, David; Taylor, Gordon D; Baillie, Thomas E C; Montgomery, David
2012-06-01
This paper describes the results of transmitted wavefront error (WFE) measurements on a volume phase holographic (VPH) grating operating at a temperature of 120 K. The VPH grating was mounted in a cryogenically compatible optical mount and tested in situ in a cryostat. The nominal root mean square (RMS) wavefront error at room temperature was 19 nm measured over a 50 mm diameter test aperture. The WFE remained at 18 nm RMS when the grating was cooled. This important result demonstrates that excellent WFE performance can be obtained with cooled VPH gratings, as required for use in future cryogenic infrared astronomical spectrometers planned for the European Extremely Large Telescope.
NASA Technical Reports Server (NTRS)
Russin, W. R.
1974-01-01
Tests were conducted to determine the performance of a hydrogen burner used to produce a test gas that simulates air entering a scramjet combustor at various flight conditions. The test gas simulates air in that it duplicates the total temperature, total pressure, and the volume fraction of oxygen of air at flight conditions. The main objective of the tests was to determine the performance of the burner as a function of the effective exhaust port area. The conclusions were: (1) pressure oscillations of the chugging type were reduced in amplitude to plus or minus 2 percent of the mean pressure level by proper sizing of hydrogen, oxygen, and air injector flow areas; (2) combustion efficiency remained essentially constant as the exhaust port area was increased by a factor of 3.4; (3) the mean total temperature determined from integrating the exit radial gas property profiles was within plus or minus 5 percent of the theoretical bulk total temperature; (4) the measured exit total temperature profile had a local peak temperature more than 30 percent greater than the theoretical bulk total temperature; and (5) measured heat transfer to the burner liner was 75 percent of that predicted by theory based on a flat radial temperature profile.
Data Summarization in the Node by Parameters (DSNP): Local Data Fusion in an IoT Environment.
Maschi, Luis F C; Pinto, Alex S R; Meneguette, Rodolfo I; Baldassin, Alexandro
2018-03-07
With the advent of the Internet of Things, billions of objects or devices are inserted into the global computer network, generating and processing data at a volume never imagined before. This paper proposes a way to collect and process local data through a data fusion technology called summarization. The main feature of the proposal is the local data fusion, through parameters provided by the application, ensuring the quality of data collected by the sensor node. In the evaluation, the sensor node was compared when performing the data summary with another that performed a continuous recording of the collected data. Two sets of nodes were created, one with a sensor node that analyzed the luminosity of the room, which in this case obtained a reduction of 97% in the volume of data generated, and another set that analyzed the temperature of the room, obtaining a reduction of 80% in the data volume. Through these tests, it has been proven that the local data fusion at the node can be used to reduce the volume of data generated, consequently decreasing the volume of messages generated by IoT environments.
NASA Astrophysics Data System (ADS)
He, Ling-Yun; Chen, Shu-Peng
2011-01-01
Nonlinear dependency between characteristic financial and commodity market quantities (variables) is crucially important, especially between trading volume and market price. Studies on nonlinear dependency between price and volume can provide practical insights into market trading characteristics, as well as the theoretical understanding of market dynamics. Actually, nonlinear dependency and its underlying dynamical mechanisms between price and volume can help researchers and technical analysts in understanding the market dynamics by integrating the market variables, instead of investigating them in the current literature. Therefore, for investigating nonlinear dependency of price-volume relationships in agricultural commodity futures markets in China and the US, we perform a new statistical test to detect cross-correlations and apply a new methodology called Multifractal Detrended Cross-Correlation Analysis (MF-DCCA), which is an efficient algorithm to analyze two spatially or temporally correlated time series. We discuss theoretically the relationship between the bivariate cross-correlation exponent and the generalized Hurst exponents for time series of respective variables. We also perform an empirical study and find that there exists a power-law cross-correlation between them, and that multifractal features are significant in all the analyzed agricultural commodity futures markets.
A Distributed GPU-Based Framework for Real-Time 3D Volume Rendering of Large Astronomical Data Cubes
NASA Astrophysics Data System (ADS)
Hassan, A. H.; Fluke, C. J.; Barnes, D. G.
2012-05-01
We present a framework to volume-render three-dimensional data cubes interactively using distributed ray-casting and volume-bricking over a cluster of workstations powered by one or more graphics processing units (GPUs) and a multi-core central processing unit (CPU). The main design target for this framework is to provide an in-core visualization solution able to provide three-dimensional interactive views of terabyte-sized data cubes. We tested the presented framework using a computing cluster comprising 64 nodes with a total of 128GPUs. The framework proved to be scalable to render a 204GB data cube with an average of 30 frames per second. Our performance analyses also compare the use of NVIDIA Tesla 1060 and 2050GPU architectures and the effect of increasing the visualization output resolution on the rendering performance. Although our initial focus, as shown in the examples presented in this work, is volume rendering of spectral data cubes from radio astronomy, we contend that our approach has applicability to other disciplines where close to real-time volume rendering of terabyte-order three-dimensional data sets is a requirement.
MacLean, Evan L.; Hare, Brian; Nunn, Charles L.; Addessi, Elsa; Amici, Federica; Anderson, Rindy C.; Aureli, Filippo; Baker, Joseph M.; Bania, Amanda E.; Barnard, Allison M.; Boogert, Neeltje J.; Brannon, Elizabeth M.; Bray, Emily E.; Bray, Joel; Brent, Lauren J. N.; Burkart, Judith M.; Call, Josep; Cantlon, Jessica F.; Cheke, Lucy G.; Clayton, Nicola S.; Delgado, Mikel M.; DiVincenti, Louis J.; Fujita, Kazuo; Herrmann, Esther; Hiramatsu, Chihiro; Jacobs, Lucia F.; Jordan, Kerry E.; Laude, Jennifer R.; Leimgruber, Kristin L.; Messer, Emily J. E.; de A. Moura, Antonio C.; Ostojić, Ljerka; Picard, Alejandra; Platt, Michael L.; Plotnik, Joshua M.; Range, Friederike; Reader, Simon M.; Reddy, Rachna B.; Sandel, Aaron A.; Santos, Laurie R.; Schumann, Katrin; Seed, Amanda M.; Sewall, Kendra B.; Shaw, Rachael C.; Slocombe, Katie E.; Su, Yanjie; Takimoto, Ayaka; Tan, Jingzhi; Tao, Ruoting; van Schaik, Carel P.; Virányi, Zsófia; Visalberghi, Elisabetta; Wade, Jordan C.; Watanabe, Arii; Widness, Jane; Young, Julie K.; Zentall, Thomas R.; Zhao, Yini
2014-01-01
Cognition presents evolutionary research with one of its greatest challenges. Cognitive evolution has been explained at the proximate level by shifts in absolute and relative brain volume and at the ultimate level by differences in social and dietary complexity. However, no study has integrated the experimental and phylogenetic approach at the scale required to rigorously test these explanations. Instead, previous research has largely relied on various measures of brain size as proxies for cognitive abilities. We experimentally evaluated these major evolutionary explanations by quantitatively comparing the cognitive performance of 567 individuals representing 36 species on two problem-solving tasks measuring self-control. Phylogenetic analysis revealed that absolute brain volume best predicted performance across species and accounted for considerably more variance than brain volume controlling for body mass. This result corroborates recent advances in evolutionary neurobiology and illustrates the cognitive consequences of cortical reorganization through increases in brain volume. Within primates, dietary breadth but not social group size was a strong predictor of species differences in self-control. Our results implicate robust evolutionary relationships between dietary breadth, absolute brain volume, and self-control. These findings provide a significant first step toward quantifying the primate cognitive phenome and explaining the process of cognitive evolution. PMID:24753565
Mechanical Properties and Shear Strengthening Capacity of High Volume Fly Ash-Cementitious Composite
NASA Astrophysics Data System (ADS)
Joseph, Aswin K.; Anand, K. B.
2018-02-01
This paper discusses development of Poly Vinyl Alcohol (PVA) fibre reinforced cementitious composites taking into account environmental sustainability. Composites with fly ash to cement ratios from 0 to 3 are investigated in this study. The mechanical properties of HVFA-cement composite are discussed in this paper at PVA fiber volume fraction maintained at 1% of total volume of composite. The optimum replacement of cement with fly ash was found to be 75%, i.e. fly ash to cement ratio (FA/C) of 3. The increase in fiber content from 1% to 2% showed better mechanical performance. A strain capacity of 2.38% was obtained for FA/C ratio of 3 with 2% volume fraction of fiber. With the objective of evaluating the performance of cementitious composites as a strengthening material in reinforced concrete beams, the beams deficient in shear capacity were strengthened with optimal mix having 2% volume fraction of fiber as the strengthening material and tested under four-point load. The reinforced concrete beams designed as shear deficient were loaded to failure and retrofitted with the composite in order to assess the efficiency as a repair material under shear.
One- and two-dimensional search of an equation of state using a newly released 2DRoptimize package
NASA Astrophysics Data System (ADS)
Jamal, M.; Reshak, A. H.
2018-05-01
A new package called 2DRoptimize has been released for performing two-dimensional searches of the equation of state (EOS) for rhombohedral, tetragonal, and hexagonal compounds. The package is compatible and available with the WIEN2k package. The 2DRoptimize package performs a convenient volume and c/a structure optimization. First, the package finds the best value for c/a and the associated energy for each volume. In the second step, it calculates the EoS. The package then finds the equation of the c/a ratio vs. volume to calculate the c/a ratio at the optimized volume. In the last stage, by using the optimized volume and c/a ratio, the 2DRoptimize package calculates a and c lattice constants for tetragonal and hexagonal compounds, as well as the a lattice constant with the α angle for rhombohedral compounds. We tested our new package based on several hexagonal, tetragonal, and rhombohedral structures, and the 2D search results for the EOS showed that this method is more accurate than 1D search. Our results agreed very well with the experimental data and they were better than previous theoretical calculations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oden, L.L.; O`Conner, W.K.; Turner, P.C.
1993-11-19
This report presents field results and raw data from the Buried Waste Integrated Demonstration (BWID) Arc Melter Vitrification Project Phase 1 baseline test series conducted by the Idaho National Engineering Laboratory (INEL) in cooperation with the U.S. Bureau of Mines (USBM). The baseline test series was conducted using the electric arc melter facility at the USBM Albany Research Center in Albany, Oregon. Five different surrogate waste feed mixtures were tested that simulated thermally-oxidized, buried, TRU-contaminated, mixed wastes and soils present at the INEL. The USBM Arc Furnace Integrated Waste Processing Test Facility includes a continuous feed system, the arc meltingmore » furnace, an offgas control system, and utilities. The melter is a sealed, 3-phase alternating current (ac) furnace approximately 2 m high and 1.3 m wide. The furnace has a capacity of 1 metric ton of steel and can process as much as 1,500 lb/h of soil-type waste materials. The surrogate feed materials included five mixtures designed to simulate incinerated TRU-contaminated buried waste materials mixed with INEL soil. Process samples, melter system operations data and offgas composition data were obtained during the baseline tests to evaluate the melter performance and meet test objectives. Samples and data gathered during this program included (a) automatically and manually logged melter systems operations data, (b) process samples of slag, metal and fume solids, and (c) offgas composition, temperature, velocity, flowrate, moisture content, particulate loading and metals content. This report consists of 2 volumes: Volume I summarizes the baseline test operations. It includes an executive summary, system and facility description, review of the surrogate waste mixtures, and a description of the baseline test activities, measurements, and sample collection. Volume II contains the raw test data and sample analyses from samples collected during the baseline tests.« less
Mastenbrook, Matthew J; Commean, Paul K; Hillen, Travis J; Salsich, Gretchen B; Meyer, Gretchen A; Mueller, Michael J; Clohisy, John C; Harris-Hayes, Marcie
2017-12-01
Study Design Secondary analysis, cross-sectional study. Background Chronic hip joint pain (CHJP) can lead to limitations in activity participation, but the musculoskeletal factors associated with the condition are relatively unknown. Understanding the factors associated with CHJP may help develop rehabilitation strategies to improve quality of life of individuals with long-term hip pain. Objectives To compare measures of hip abductor muscle volume and hip abductor muscle strength between women with CHJP and asymptomatic controls. Methods Thirty women, 15 with CHJP and 15 matched asymptomatic controls (age range, 18-40 years), participated in this study. Magnetic resonance imaging was used to determine the volume of the primary hip abductor muscles, consisting of the gluteus medius, gluteus minimus, a small portion of the gluteus maximus, and the tensor fascia latae, within a defined region of interest. Break tests were performed using a handheld dynamometer to assess hip abductor strength. During the strength test, the participant was positioned in sidelying with the involved hip in 15° of abduction. Independent-samples t tests were used to compare muscle volume and strength values between those with CHJP and asymptomatic controls. Results Compared to asymptomatic controls, women with CHJP demonstrated significantly increased gluteal muscle volume (228 ± 40 cm 3 versus 199 ± 29 cm 3 , P = .032), but decreased hip abductor strength (74.6 ± 16.8 Nm versus 93.6 ± 20.2 Nm, P = .009). There were no significant differences in tensor fascia lata muscle volume between the 2 groups (P = .640). Conclusion Women with CHJP appear to have larger gluteal muscle volume, but decreased hip abductor strength, compared to asymptomatic controls. J Orthop Sports Phys Ther 2017;47(12):923-930. Epub 9 Oct 2017. doi:10.2519/jospt.2017.7380.
Uzun, I; Keleş, A; Arslan, H; Güler, B; Keskin, C; Gündüz, K
2016-12-01
To evaluate the percentage volume of voids within cement layers, to determine the push-out bond strength of circular and oval fibre posts luted with different commercial resin cements in oval cross-sectional root canals, and to correlate push-out bond strength values and volume of voids of circular and oval fibre posts. Seventy-two mandibular premolars with oval-shaped root canals were selected. The specimens were divided into two main groups according to the post type (oval and circular). Groups were further divided into three subgroups (n = 24) according to resin cement type: Maxcem Elite, Rely-X Unicem and Duo-Link. The volumes of voids within the cements were analysed by micro-computed tomography (micro-CT). The bond strength was then measured using a push-out test with an Instron universal testing machine. The failure modes were evaluated. Statistical analyses were performed using a three-way anova, Tukey's post hoc, Pearson's correlation and chi-square test (P = 0.05). The push-out bond strength values were significantly affected by root canal region, post type and cement type (P < 0.001). Root canal region, post type and cement type also significantly affected void volume (P < 0.001). There was a significant interaction between post type and cement type (P < 0.001). The most frequent failure type was adhesive failure in all the groups. There was no significant correlation between the push-out bond strength and void volume (P > 0.05). Void volume did not affect push-out bond strength of oval and circular posts luted in oval canals. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Schneider, Caroline; Forsythe, Lynsey; Somauroo, John; George, Keith; Oxborough, David
2018-01-03
Left ventricular (LV) function is dependent on load, intrinsic contractility and relaxation with a variable impact on specific mechanics. Strain (ε) imaging allows the assessment of cardiac function however the direct relationship between volume and strain is currently unknown. The aim of this study was to establish the impact of preload reduction through head-up tilt (HUT) testing on simultaneous left ventricular (LV) longitudinal and transverse function and their respective contribution to volume change. A focused transthoracic echocardiogram was performed on 10 healthy male participants (23 ± 3 years,) in the supine position and following 1 min and 5 min of HUT testing. Raw temporal longitudinal ε (Ls) and transverse ε (Ts) values were exported and divided into 5% increments across the cardiac cycle and corresponding LV volumes were traced at each 5% increment. This provided simultaneous LV longitudinal and transverse ε and volume-loops (deformation-volume analysis - DVA). There was a leftward- shift of the ε -volume loop from supine to 1 min and 5 min of HUT, p<0.001). Moreover, longitudinal shortening was reduced (p<0.001) with a concomitant increase in transverse thickening from supine to 1min, which was further augmented at 5min (p=0.018). Preload reduction occurs within 1 minute of HUT but does not further reduce at 5 minutes. This decline is associated with a decrease in longitudinal ε and concomitant increase in transverse ε. Consequently, augmented transverse relaxation appears to be an important factor in the maintenance of LV filling in the setting of reduced preload. DVA provides information on the relative contribution of mechanics to a change in LV volume and may have a role in the assessment of clinical populations. © 2018 The authors.
NASA Technical Reports Server (NTRS)
1982-01-01
A focused laser doppler velocimeter (LDV) system was developed for the measurement of atmospheric backscatter (beta) from aerosols at infrared wavelengths. A Doppler signal generator was used in mapping the coherent sensitive focal volume of a focused LDV system. System calibration data was analyzed during the flight test activity scheduled for the Beta system. These analyses were performed to determine the acceptability of the Beta measurement system's performance.
The influence of cellulose nanocrystal additions on the performance of cement paste
Yizheng Cao; Pablo Zavaterri; Jeff Youngblood; Robert Moon; Jason Weiss
2015-01-01
The influence of cellulose nanocrystals (CNCs) addition on the performance of cement paste was investigated. Our mechanical tests show an increase in the flexural strength of approximately 30% with only 0.2% volume of CNCs with respect to cement. Isothermal calorimetry (IC) and thermogravimetric analysis (TGA) show that the degree of hydration (DOH) of the cement paste...
Viking lander camera radiometry calibration report, volume 2
NASA Technical Reports Server (NTRS)
Wolf, M. R.; Atwood, D. L.; Morrill, M. E.
1977-01-01
The requirements the performance validation, and interfaces for the RADCAM program, to convert Viking lander camera image data to radiometric units were established. A proposed algorithm is described, and an appendix summarizing the planned reduction of camera test data was included.
DOT National Transportation Integrated Search
1974-01-01
This report contains the results of an experimental and analytical evaluation of instruments and techniques designed to prevent an intoxicated driver from operating his automobile. The prototype 'Alcohol Safety Interlock Systems' tested were develope...
Breathing simulator of workers for respirator performance test
YUASA, Hisashi; KUMITA, Mikio; HONDA, Takeshi; KIMURA, Kazushi; NOZAKI, Kosuke; EMI, Hitoshi; OTANI, Yoshio
2014-01-01
Breathing machines are widely used to evaluate respirator performance but they are capable of generating only limited air flow patterns, such as, sine, triangular and square waves. In order to evaluate the respirator performance in practical use, it is desirable to test the respirator using the actual breathing patterns of wearers. However, it has been a difficult task for a breathing machine to generate such complicated flow patterns, since the human respiratory volume changes depending on the human activities and workload. In this study, we have developed an electromechanical breathing simulator and a respiration sampling device to record and reproduce worker’s respiration. It is capable of generating various flow patterns by inputting breathing pattern signals recorded by a computer, as well as the fixed air flow patterns. The device is equipped with a self-control program to compensate the difference in inhalation and exhalation volume and the measurement errors on the breathing flow rate. The system was successfully applied to record the breathing patterns of workers engaging in welding and reproduced the breathing patterns. PMID:25382381
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, W.H.; Gopalakrishnan, S.; Fehlau, R.
1982-03-01
As a result of prior EPRI-sponsored studies, it was concluded that a research program should be designed and implemented to provide an improved basis for the design, procurement, testing, and operation of large feed pumps with increased reliability and stability over the full range of operating conditions. This two-volume report contains a research plan which is based on a review of the present state of the art and which defines the necessary R and D program and estimates the benefits and costs of the program. The recommended research program consists of 30 interrelated tasks. It is designed to perform themore » needed research; to verify the results; to develop improved components; and to publish computer-aided design methods, pump specification guidelines, and a troubleshooting manual. Most of the technology proposed in the research plan is applicable to nuclear power plants as well as to fossil-fired plants. This volume contains appendixes on pump design, cavitation damage, performance testing, hydraulics, two-phase flow in pumps, flow stability, and rotor dynamics.« less
Brain tissues volume measurements from 2D MRI using parametric approach
NASA Astrophysics Data System (ADS)
L'vov, A. A.; Toropova, O. A.; Litovka, Yu. V.
2018-04-01
The purpose of the paper is to propose a fully automated method of volume assessment of structures within human brain. Our statistical approach uses maximum interdependency principle for decision making process of measurements consistency and unequal observations. Detecting outliers performed using maximum normalized residual test. We propose a statistical model which utilizes knowledge of tissues distribution in human brain and applies partial data restoration for precision improvement. The approach proposes completed computationally efficient and independent from segmentation algorithm used in the application.
NASA Technical Reports Server (NTRS)
Niiya, Karen E.; Walker, Richard E.; Pieper, Jerry L.; Nguyen, Thong V.
1993-01-01
This final report includes a discussion of the work accomplished during the period from Dec. 1988 through Nov. 1991. The objective of the program was to assemble existing performance and combustion stability models into a usable design methodology capable of designing and analyzing high-performance and stable LOX/hydrocarbon booster engines. The methodology was then used to design a validation engine. The capabilities and validity of the methodology were demonstrated using this engine in an extensive hot fire test program. The engine used LOX/RP-1 propellants and was tested over a range of mixture ratios, chamber pressures, and acoustic damping device configurations. This volume contains time domain and frequency domain stability plots which indicate the pressure perturbation amplitudes and frequencies from approximately 30 tests of a 50K thrust rocket engine using LOX/RP-1 propellants over a range of chamber pressures from 240 to 1750 psia with mixture ratios of from 1.2 to 7.5. The data is from test configurations which used both bitune and monotune acoustic cavities and from tests with no acoustic cavities. The engine had a length of 14 inches and a contraction ratio of 2.0 using a 7.68 inch diameter injector. The data was taken from both stable and unstable tests. All combustion instabilities were spontaneous in the first tangential mode. Although stability bombs were used and generated overpressures of approximately 20 percent, no tests were driven unstable by the bombs. The stability instrumentation included six high-frequency Kistler transducers in the combustion chamber, a high-frequency Kistler transducer in each propellant manifold, and tri-axial accelerometers. Performance data is presented, both characteristic velocity efficiencies and energy release efficiencies, for those tests of sufficient duration to record steady state values.
Ferguson, Philip E; Sales, Catherine M; Hodges, Dalton C; Sales, Elizabeth W
2015-01-01
Recent publications have emphasized the importance of a multidisciplinary strategy for maximum conservation and utilization of lung biopsy material for advanced testing, which may determine therapy. This paper quantifies the effect of a multidisciplinary strategy implemented to optimize and increase tissue volume in CT-guided transthoracic needle core lung biopsies. The strategy was three-pronged: (1) once there was confidence diagnostic tissue had been obtained and if safe for the patient, additional biopsy passes were performed to further increase volume of biopsy material, (2) biopsy material was placed in multiple cassettes for processing, and (3) all tissue ribbons were conserved when cutting blocks in the histology laboratory. This study quantifies the effects of strategies #1 and #2. This retrospective analysis comparing CT-guided lung biopsies from 2007 and 2012 (before and after multidisciplinary approach implementation) was performed at a single institution. Patient medical records were reviewed and main variables analyzed include biopsy sample size, radiologist, number of blocks submitted, diagnosis, and complications. The biopsy sample size measured was considered to be directly proportional to tissue volume in the block. Biopsy sample size increased 2.5 fold with the average total biopsy sample size increasing from 1.0 cm (0.9-1.1 cm) in 2007 to 2.5 cm (2.3-2.8 cm) in 2012 (P<0.0001). The improvement was statistically significant for each individual radiologist. During the same time, the rate of pneumothorax requiring chest tube placement decreased from 15% to 7% (P = 0.065). No other major complications were identified. The proportion of tumor within the biopsy material was similar at 28% (23%-33%) and 35% (30%-40%) for 2007 and 2012, respectively. The number of cases with at least two blocks available for testing increased from 10.7% to 96.4% (P<0.0001). The effect of this multidisciplinary strategy to CT-guided lung biopsies was effective in significantly increasing tissue volume and number of blocks available for advanced diagnostic testing.
Gundersen, Guri Holmen; Norekval, Tone M; Haug, Hilde Haugberg; Skjetne, Kyrre; Kleinau, Jens Olaf; Graven, Torbjorn; Dalen, Havard
2016-01-01
Objectives Medical history, physical examination and laboratory testing are not optimal for the assessment of volume status in heart failure (HF) patients. We aimed to study the clinical influence of focused ultrasound of the pleural cavities and inferior vena cava (IVC) performed by specialised nurses to assess volume status in HF patients at an outpatient clinic. Methods HF outpatients were prospectively included and underwent laboratory testing, history recording and clinical examination by two nurses with and without an ultrasound examination of the pleural cavities and IVC using a pocket-size imaging device, in random order. Each nurse worked in a team with a cardiologist. The influence of the different diagnostic tests on diuretic dosing was assessed descriptively and in linear regression analyses. Results Sixty-two patients were included and 119 examinations were performed. Mean±SD age was 74±12 years, EF was 34±14%, and N-terminal pro-brain natriuretic peptide (NT-proBNP) value was 3761±3072 ng/L. Dosing of diuretics differed between the teams in 31 out of 119 consultations. Weight change and volume status assessed clinically with and without ultrasound predicted dose adjustment of diuretics at follow-up (p<0.05). Change of oedema, NT-proBNP, creatinine, and symptoms did not (p≥0.10). In adjusted analyses, only volume status based on ultrasound predicted dose adjustments of diuretics at first visit and follow-up (all ultrasound p≤0.01, all other p≥0.2). Conclusions Ultrasound examinations of the pleural cavities and IVC by nurses may improve diagnostics and patient care in HF patients at an outpatient clinic, but more studies are needed to determine whether these examinations have an impact on clinical outcomes. Trial registration number NCT01794715. PMID:26438785
Gundersen, Guri Holmen; Norekval, Tone M; Haug, Hilde Haugberg; Skjetne, Kyrre; Kleinau, Jens Olaf; Graven, Torbjorn; Dalen, Havard
2016-01-01
Medical history, physical examination and laboratory testing are not optimal for the assessment of volume status in heart failure (HF) patients. We aimed to study the clinical influence of focused ultrasound of the pleural cavities and inferior vena cava (IVC) performed by specialised nurses to assess volume status in HF patients at an outpatient clinic. HF outpatients were prospectively included and underwent laboratory testing, history recording and clinical examination by two nurses with and without an ultrasound examination of the pleural cavities and IVC using a pocket-size imaging device, in random order. Each nurse worked in a team with a cardiologist. The influence of the different diagnostic tests on diuretic dosing was assessed descriptively and in linear regression analyses. Sixty-two patients were included and 119 examinations were performed. Mean±SD age was 74±12 years, EF was 34±14%, and N-terminal pro-brain natriuretic peptide (NT-proBNP) value was 3761±3072 ng/L. Dosing of diuretics differed between the teams in 31 out of 119 consultations. Weight change and volume status assessed clinically with and without ultrasound predicted dose adjustment of diuretics at follow-up (p<0.05). Change of oedema, NT-proBNP, creatinine, and symptoms did not (p≥0.10). In adjusted analyses, only volume status based on ultrasound predicted dose adjustments of diuretics at first visit and follow-up (all ultrasound p≤0.01, all other p≥0.2). Ultrasound examinations of the pleural cavities and IVC by nurses may improve diagnostics and patient care in HF patients at an outpatient clinic, but more studies are needed to determine whether these examinations have an impact on clinical outcomes. NCT01794715. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Development of modelling algorithm of technological systems by statistical tests
NASA Astrophysics Data System (ADS)
Shemshura, E. A.; Otrokov, A. V.; Chernyh, V. G.
2018-03-01
The paper tackles the problem of economic assessment of design efficiency regarding various technological systems at the stage of their operation. The modelling algorithm of a technological system was performed using statistical tests and with account of the reliability index allows estimating the level of machinery technical excellence and defining the efficiency of design reliability against its performance. Economic feasibility of its application shall be determined on the basis of service quality of a technological system with further forecasting of volumes and the range of spare parts supply.
NASA Technical Reports Server (NTRS)
Kuhlman, E. A.
1974-01-01
An S-band antenna system and a group of off-the-shelf aircraft antenna were exposed to temperatures simulating shuttle orbital cold soak and entry heating. Radiation pattern and impedance measurements before and after exposure to the thermal environments were used to evaluate the electrical performance. The results of the electrical and thermal testing are given. Test data showed minor changes in electrical performance and established the capability of these antenna to withstand both the low temperatures of space flight and the high temperatures of entry.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fischer, W.; Shiota, T.
Two categories of NaS traction batteries will be discussed: the present battery of Asea Brown Boveri and Powerplex and potential future NaS traction batteries. A large number of our present 24 kWh - 35 kw battery has been subjected to bench and on-vehicle performance tests. Test results will be presented. Future battery types to be volume produced in the early 1990`s are discussed with regard to energy, power and shape for special applications such a passenger car and van propulsion. Examples for those batteries will be given and projected performance characteristiques will be discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fischer, W.; Shiota, T.
Two categories of NaS traction batteries will be discussed: the present battery of Asea Brown Boveri and Powerplex and potential future NaS traction batteries. A large number of our present 24 kWh - 35 kw battery has been subjected to bench and on-vehicle performance tests. Test results will be presented. Future battery types to be volume produced in the early 1990's are discussed with regard to energy, power and shape for special applications such a passenger car and van propulsion. Examples for those batteries will be given and projected performance characteristiques will be discussed.
Handheld Universal Diagnostic Sensor
NASA Technical Reports Server (NTRS)
Chan, Eugene
2012-01-01
The rHEALTH technology is designed to shrink an entire hospital testing laboratory onto a handheld device. A physician or healthcare provider performs the test by collecting a fingerstick of blood from a patient. The tiny volume of blood is inserted into the rHEALTH device. Inside the device is a microfluidic chip that contains small channels about the width of a human hair. These channels help move the blood and analyze the blood sample. The rHEALTH sensor uses proprietary reagents called nanostrips, which are nanoscale test strips that enable the clinical assays. The readout is performed by laser-induced fluorescence. Overall, the time from blood collection through analysis is less than a minute.
Esteban-Cornejo, Irene; Cadenas-Sanchez, Cristina; Contreras-Rodriguez, Oren; Verdejo-Roman, Juan; Mora-Gonzalez, Jose; Migueles, Jairo H; Henriksson, Pontus; Davis, Catherine L; Verdejo-Garcia, Antonio; Catena, Andrés; Ortega, Francisco B
2017-10-01
Obesity, as compared to normal weight, is associated with detectable structural differences in the brain. To the best of our knowledge, no previous study has examined the association of physical fitness with gray matter volume in overweight/obese children using whole brain analyses. Thus, the aim of this study was to examine the association between the key components of physical fitness (i.e. cardiorespiratory fitness, speed-agility and muscular fitness) and brain structural volume, and to assess whether fitness-related changes in brain volumes are related to academic performance in overweight/obese children. A total of 101 overweight/obese children aged 8-11 years were recruited from Granada, Spain. The physical fitness components were assessed following the ALPHA health-related fitness test battery. T1-weighted images were acquired with a 3.0 T S Magnetom Tim Trio system. Gray matter tissue was calculated using Diffeomorphic Anatomical Registration Through Exponentiated Lie algebra (DARTEL). Academic performance was assessed by the Batería III Woodcock-Muñoz Tests of Achievement. All analyses were controlled for sex, peak high velocity offset, parent education, body mass index and total brain volume. The statistical threshold was calculated with AlphaSim and further Hayasaka adjusted to account for the non-isotropic smoothness of structural images. The main results showed that higher cardiorespiratory fitness was related to greater gray matter volumes (P < 0.001, k = 64) in 7 clusters with β ranging from 0.493 to 0.575; specifically in frontal regions (i.e. premotor cortex and supplementary motor cortex), subcortical regions (i.e. hippocampus and caudate), temporal regions (i.e. inferior temporal gyrus and parahippocampal gyrus) and calcarine cortex. Three of these regions (i.e. premotor cortex, supplementary motor cortex and hippocampus) were related to better academic performance (β ranging from 0.211 to 0.352; all P < 0.05). Higher speed-agility was associated with greater gray matter volumes (P < 0.001, k = 57) in 2 clusters (i.e. the inferior frontal gyrus and the superior temporal gyrus) with β ranging from 0.564 to 0.611. Both clusters were related to better academic performance (β ranging from 0.217 to 0.296; both P < 0.05). Muscular fitness was not independently associated with greater gray matter volume in any brain region. Furthermore, there were no statistically significant negative association between any component of physical fitness and gray matter volume in any region of the brain. In conclusion, cardiorespiratory fitness and speed-agility, but not muscular fitness, may independently be associated with greater volume of numerous cortical and subcortical brain structures; besides, some of these brain structures may be related to better academic performance. Importantly, the identified associations of fitness and gray matter volume were different for each fitness component. These findings suggest that increases in cardiorespiratory fitness and speed-agility may positively influence the development of distinctive brain regions and academic indicators, and thus counteract the harmful effect of overweight and obesity on brain structure during childhood. Copyright © 2017 Elsevier Inc. All rights reserved.
Humidity Testing for Human Rated Spacecraft
NASA Technical Reports Server (NTRS)
Johnson, Gary B.
2009-01-01
Determination that equipment can operate in and survive exposure to the humidity environments unique to human rated spacecraft presents widely varying challenges. Equipment may need to operate in habitable volumes where the atmosphere contains perspiration, exhalation, and residual moisture. Equipment located outside the pressurized volumes may be exposed to repetitive diurnal cycles that may result in moisture absorption and/or condensation. Equipment may be thermally affected by conduction to coldplate or structure, by forced or ambient air convection (hot/cold or wet/dry), or by radiation to space through windows or hatches. The equipment s on/off state also contributes to the equipment s susceptibility to humidity. Like-equipment is sometimes used in more than one location and under varying operational modes. Due to these challenges, developing a test scenario that bounds all physical, environmental and operational modes for both pressurized and unpressurized volumes requires an integrated assessment to determine the "worst-case combined conditions." Such an assessment was performed for the Constellation program, considering all of the aforementioned variables; and a test profile was developed based on approximately 300 variable combinations. The test profile has been vetted by several subject matter experts and partially validated by testing. Final testing to determine the efficacy of the test profile on actual space hardware is in the planning stages. When validation is completed, the test profile will be formally incorporated into NASA document CxP 30036, "Constellation Environmental Qualification and Acceptance Testing Requirements (CEQATR)."
Large Volume, Optical and Opto-Mechanical Metrology Techniques for ISIM on JWST
NASA Technical Reports Server (NTRS)
Hadjimichael, Theo
2015-01-01
The final, flight build of the Integrated Science Instrument Module (ISIM) element of the James Webb Space Telescope is the culmination of years of work across many disciplines and partners. This paper covers the large volume, ambient, optical and opto-mechanical metrology techniques used to verify the mechanical integration of the flight instruments in ISIM, including optical pupil alignment. We present an overview of ISIM's integration and test program, which is in progress, with an emphasis on alignment and optical performance verification. This work is performed at NASA Goddard Space Flight Center, in close collaboration with the European Space Agency, the Canadian Space Agency, and the Mid-Infrared Instrument European Consortium.
Lobigs, Louisa M; Sottas, Pierre-Edouard; Bourdon, Pitre C; Nikolovski, Zoran; El-Gingo, Mohamed; Varamenti, Evdokia; Peeling, Peter; Dawson, Brian; Schumacher, Yorck O
2018-02-01
The haematological module of the Athlete's Biological Passport (ABP) has significantly impacted the prevalence of blood manipulations in elite sports. However, the ABP relies on a number of concentration-based markers of erythropoiesis, such as haemoglobin concentration ([Hb]), which are influenced by shifts in plasma volume (PV). Fluctuations in PV contribute to the majority of biological variance associated with volumetric ABP markers. Our laboratory recently identified a panel of common chemistry markers (from a simple blood test) capable of describing ca 67% of PV variance, presenting an applicable method to account for volume shifts within anti-doping practices. Here, this novel PV marker was included into the ABP adaptive model. Over a six-month period (one test per month), 33 healthy, active males provided blood samples and performed the CO-rebreathing method to record PV (control). In the final month participants performed a single maximal exercise effort to promote a PV shift (mean PV decrease -17%, 95% CI -9.75 to -18.13%). Applying the ABP adaptive model, individualized reference limits for [Hb] and the OFF-score were created, with and without the PV correction. With the PV correction, an average of 66% of [Hb] within-subject variance is explained, narrowing the predicted reference limits, and reducing the number of atypical ABP findings post-exercise. Despite an increase in sensitivity there was no observed loss of specificity with the addition of the PV correction. The novel PV marker presented here has the potential to improve the ABP's rate of correct doping detection by removing the confounding effects of PV variance. Copyright © 2017 John Wiley & Sons, Ltd.
MacMillan, Donna; Lewandrowski, Elizabeth; Lewandrowski, Kent
2004-01-01
Utilization of outside reference laboratories for selected laboratory testing is common in the United States. However, relatively little data exist in the literature describing the scope and impact of these services. In this study, we reviewed use of reference laboratory testing at the Massachusetts General Hospital, a large urban academic medical center in Boston, Massachusetts. A retrospective review of hospital and laboratory administrative records over an 8-year period from fiscal years (FY) 1995-2002. Over the 8 years studied, reference laboratory expenses increased 4.2-fold and totaled 12.4% of the total laboratory budget in FY 2002. Total reference laboratory test volume increased 4-fold to 68,328 tests in FY 2002 but represented only 1.06% of the total test volume in the hospital. The menu of reference laboratory tests comprised 946 tests (65.7% of the hospital test menu) compared to 494 (34.3%) of tests performed in house. The average unit cost of reference laboratory tests was essentially unchanged but was approximately 13 times greater than the average unit cost in the hospital laboratory. Much of the growth in reference laboratory cost can be attributed to the addition of new molecular, genetic, and microbiological assays. Four of the top 10 tests with the highest total cost in 2002 were molecular diagnostic tests that were recently added to the test menu. Reference laboratory testing comprises a major component of hospital clinical laboratory services. Although send out tests represent a small percentage of the total test volume, these services account for the majority of the hospital laboratory test menu and a disproportionate percentage of laboratory costs.
Lopez, Katherine C; Leary, Jacob B; Pham, Dzung L; Chou, Yi-Yu; Dsurney, John; Chan, Leighton
2017-01-01
Post-traumatic stress disorder (PTSD) is commonly associated with mild traumatic brain injury (mTBI). To better understand their relationship, we examined neuroanatomical structures and neuropsychological performance in a sample of individuals with mTBI, with and without PTSD symptoms. Thirty-nine subjects with mTBI were dichotomized into those with (n = 12) and without (n = 27) significant PTSD symptoms based on scores on the PTSD Checklist. Using a region-of-interest approach, fronto-temporal volumes, fiber bundles obtained by diffusion tensor imaging, and neuropsychological scores were compared between the two groups. After controlling for total intracranial volume and age, subjects with mTBI and PTSD symptoms exhibited volumetric differences in the entorhinal cortex, an area associated with memory networks, relative to mTBI-only patients (F = 4.28; p = 0.046). Additionally, subjects with PTSD symptoms showed reduced white matter integrity in the right cingulum bundle (axial diffusivity, F = 6.04; p = 0.020). Accompanying these structural alterations, mTBI and PTSD subjects also showed impaired performance in encoding (F = 5.98; p = 0.019) and retrieval (F = 7.32; p = 0.010) phases of list learning and in tests of processing speed (Wechsler Adult Intelligence Scale Processing Speed Index, F = 12.23; p = 0.001; Trail Making Test A, F = 5.56; p = 0.024). Increased volume and white matter disruptions in these areas, commonly associated with memory functions, may be related to functional disturbances during cognitively demanding tasks. Differences in brain volume and white matter integrity between mTBI subjects and those with mTBI and co-morbid PTSD symptoms point to neuroanatomical differences that may underlie poorer recovery of mTBI subjects who experience PTSD symptoms. These findings support theoretical models of PTSD and its relationship to learning deficits.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oden, L.L.; O`Connor, W.K.; Turner, P.C.
1993-11-19
This report presents field results and raw data from the Buried Waste Integrated Demonstration (BWID) Arc Melter Vitrification Project Phase 1 baseline test series conducted by the Idaho National Engineering Laboratory (INEL) in cooperation with the U.S. Bureau of Mines (USBM). The baseline test series was conducted using the electric arc melter facility at the USBM Albany Research Center in Albany, Oregon. Five different surrogate waste feed mixtures were tested that simulated thermally-oxidized, buried, TRU-contaminated, mixed wastes and soils present at the INEL. The USBM Arc Furnace Integrated Waste Processing Test Facility includes a continuous feed system, the arc meltingmore » furnace, an offgas control system, and utilities. The melter is a sealed, 3-phase alternating current (ac) furnace approximately 2 m high and 1.3 m wide. The furnace has a capacity of 1 metric ton of steel and can process as much as 1,500 lb/h of soil-type waste materials. The surrogate feed materials included five mixtures designed to simulate incinerated TRU-contaminated buried waste materials mixed with INEL soil. Process samples, melter system operations data and offgas composition data were obtained during the baseline tests to evaluate the melter performance and meet test objectives. Samples and data gathered during this program included (a) automatically and manually logged melter systems operations data, (b) process samples of slag, metal and fume solids, and (c) offgas composition, temperature, velocity, flowrate, moisture content, particulate loading and metals content. This report consists of 2 volumes: Volume I summarizes the baseline test operations. It includes an executive summary, system and facility description, review of the surrogate waste mixtures, and a description of the baseline test activities, measurements, and sample collection. Volume II contains the raw test data and sample analyses from samples collected during the baseline tests.« less
Fraga de Abreu, Vitor Hugo; Peck, Kyung K.; Petrovich-Brennan, Nicole M.; Woo, Kaitlin M.
2016-01-01
Purpose To evaluate the effects of histologic features and anatomic magnetic resonance (MR) imaging characteristics of brain tumors on the functional MR imaging signal in the primary motor cortex (PMC), as false-negative blood oxygen level–dependent (BOLD) functional MR imaging activation can limit the accurate localization of eloquent cortices. Materials and Methods Institutional review board approval was obtained, and informed consent was waived for this HIPAA-compliant retrospective study. It comprised 63 patients referred between 2006 and 2014 for preoperative functional MR imaging localization of the Rolandic cortex. The patients had glioblastoma multiforme (GBM) (n = 20), metastasis (n = 21), or meningioma (n = 22). The volumes of functional MR imaging activation were measured during performance of a bilateral hand motor task. Ratios of functional MR imaging activation were normalized to PMC volume. Statistical analysis was performed for the following: (a) differences between hemispheres within each histologic tumor type (paired Wilcoxon test), (b) differences across tumor types (Kruskal-Wallis and Fisher tests), (c) pairwise tests between tumor types (Mann-Whitney U test), (d) relationships between fast fluid-attenuated inversion recovery (FLAIR) data and enhancement volume with activation (Spearman rank correlation coefficient), and (e) differences in activation volumes by tumor location (Mann-Whitney U test). Results A significant interhemispheric difference was found between the activation volumes in GBMs (mean, 511.43 voxels ± 307.73 [standard deviation] and 330.78 voxels ± 278.95; P < .01) but not in metastases (504.68 voxels ± 220.98 and 460.22 voxels ± 276.83; P = .15) or meningiomas (424.07 voxels ± 247.58 and 415.18 voxels ± 222.36; P = .85). GBMs showed significantly lower activation ratios (median, 0.49; range, 0.04–1.15) than metastases (median, 0.79; range, 0.28–1.66; P = .043) and meningiomas (median, 0.91; range, 0.52–2.05; P < .01). There was a moderate correlation with the volumes of FLAIR abnormality in metastases (ρ = −0.50) and meningiomas (ρ = −0.55). Enhancement volume (ρ = −0.11) and tumor distance from the PMC (median, 0.73 and range, 0.04–2.05 for near and median, 0.82 and range, 0.39–1.66 for far; P = .14) did not influence activation. Conclusion BOLD functional MR imaging activation in the ipsilateral PMC is influenced by tumor type and is significantly reduced in GBMs. FLAIR abnormality correlates moderately with the activation ratios in metastases and meningiomas. © RSNA, 2016 Online supplemental material is available for this article. PMID:27383533
Scale effects on the transverse tensile strength of graphite epoxy composites
NASA Technical Reports Server (NTRS)
Obrien, T. Kevin; Salpekar, Satish A.
1992-01-01
The influence of material volume on the transverse tensile strength of AS4/3501-6 graphite epoxy composites was investigated. Tensile tests of 90 degree laminates with 3 different widths and 5 different thicknesses were conducted. A finite element analysis was performed to determine the influence of the grip on the stress distribution in the coupons and explain the tendency for the distribution of failure locations to be skewed toward the grip. Specimens were instrumented with strain gages and extensometers to insure good alignment and to measure failure strains. Data indicated that matrix dominated strength properties varied with the volume of material that was stressed, with the strength decreasing as volume increased. Transverse strength data were used in a volumetric scaling law based on Weibull statistics to predict the strength of 90 degree laminates loaded in three point bending. Comparisons were also made between transverse strength measurements and out-of-plane interlaminar tensile strength measurements from curved beam bending tests. The significance of observed scale effects on the use of tests for material screening, quality assurance, and design allowables is discussed.
Felt-Bersma, R J; Sloots, C E; Poen, A C; Cuesta, M A; Meuwissen, S G
2000-12-01
The clinical impact of rectal compliance and sensitivity measurement is not clear. The aim of this study was to measure the rectal compliance in different patient groups compared with controls and to establish the clinical effect of rectal compliance. Anorectal function tests were performed in 974 consecutive patients (284 men). Normal values were obtained from 24 controls. Rectal compliance measurement was performed by filling a latex rectal balloon with water at a rate of 60 ml per minute. Volume and intraballoon pressure were measured. Volume and pressure at three sensitivity thresholds were recorded for analysis: first sensation, urge, and maximal toleration. At maximal toleration, the rectal compliance (volume/pressure) was calculated. Proctoscopy, anal manometry, anal mucosal sensitivity, and anal endosonography were also performed as part of our anorectal function tests. No effect of age or gender was observed in either controls or patients. Patients with fecal incontinence had a higher volume at first sensation and a higher pressure at maximal toleration (P = 0.03), the presence of a sphincter defect or low or normal anal pressures made no difference. Patients with constipation had a larger volume at first sensation and urge (P < 0.0001 and P < 0.01). Patients with a rectocele had a larger volume at first sensation (P = 0.004). Patients with rectal prolapse did not differ from controls; after rectopexy, rectal compliance decreased (P < 0.0003). Patients with inflammatory bowel disease had a lower rectal compliance, most pronounced in active proctitis (P = 0.003). Patients with ileoanal pouches also had a lower compliance (P < 0.0001). In the 17 patients where a maximal toleration volume < 60 ml was found, 11 had complaints of fecal incontinence, and 6 had a stoma. In 31 patients a maximal toleration volume between 60 and 100 ml was found; 12 patients had complaints of fecal incontinence, and 6 had a stoma. Proctitis or pouchitis was the main cause for a small compliance. All 29 patients who had a maximal toleration volume > 500 ml had complaints of constipation. No correlation between rectal and anal mucosal sensitivity was found. Rectal compliance measurement with a latex balloon is easily feasible. In this series of 974 patients, some patient groups showed an abnormal rectal visceral sensitivity and compliance, but there was an overlap with controls. Rectal compliance measurement gave a good clinical impression about the contribution of the rectum to the anorectal problem. Patients with proctitis and pouchitis had the smallest rectal compliance. A maximal toleration volume < 60 ml always led to fecal incontinence, and stomas should be considered for such patients. A maximal toleration volume > 500 ml was only seen in constipated patients, and therapy should be given to prevent further damage to the pelvic floor. Values close to or within the normal range rule out the rectum as an important factor in the anorectal problem of the patient.
NASA Astrophysics Data System (ADS)
Fisher, Mark; Sikes, John; Prather, Mark
2004-09-01
The dog's nose is an effective, highly-mobile sampling system, while the canine olfactory organs are an extremely sensitive detector. Having been trained to detect a wide variety of substances with exceptional results, canines are widely regarded as the 'gold standard' in chemical vapor detection. Historically, attempts to mimic the ability of dogs to detect vapors of explosives using electronic 'dogs noses' has proven difficult. However, recent advances in technology have resulted in development of detection (i.e., sampling and sensor) systems with performance that is rapidly approaching that of trained canines. The Nomadics Fido was the first sensor to demonstrate under field conditions the detection of landmines with performance approaching that of canines. More recently, comparative testing of Fido against canines has revealed that electronic vapor detection, when coupled with effective sampling methods, can produce results comparable to that of highly-trained canines. The results of these comparative tests will be presented, as will recent test results in which explosives hidden in cargo were detected using Fido with a high-volume sampling technique. Finally, the use of canines along with electronic sensors will be discussed as a means of improving the performance and expanding the capabilities of both methods.
International Space Station (ISS)
2003-01-16
In this International Space Station (ISS) onboard photo, Expedition Six Science Officer Donald R. Pettit works to set up the Pulmonary Function in Flight (PuFF) experiment hardware in the Destiny Laboratory. Expedition Six is the fourth and final crew to perform the PuFF experiment. The PuFF experiment was developed to better understand what effects long term exposure to microgravity may have on the lungs. The focus is on measuring changes in the everness of gas exchange in the lungs, and on detecting changes in respiratory muscle strength. It allows astronauts to measure blood flow through the lungs, the ability of the lung to take up oxygen, and lung volumes. Each PuFF session includes five lung function tests, which involve breathing only cabin air. For each planned extravehicular (EVA) activity, a crew member performs a PuFF test within one week prior to the EVA. Following the EVA, those crew members perform another test to document the effect of exposure of the lungs to the low-pressure environment of the space suits. This experiment utilizes the Gas Analyzer System for Metabolic Analysis Physiology, or GASMAP, located in the Human Research Facility (HRF), along with a variety of other Puff equipment including a manual breathing valve, flow meter, pressure-flow module, pressure and volume calibration syringes, and disposable mouth pieces.
Pulmonary Function in Flight (PuFF) Experiment
NASA Technical Reports Server (NTRS)
2003-01-01
In this International Space Station (ISS) onboard photo, Expedition Six Science Officer Donald R. Pettit works to set up the Pulmonary Function in Flight (PuFF) experiment hardware in the Destiny Laboratory. Expedition Six is the fourth and final crew to perform the PuFF experiment. The PuFF experiment was developed to better understand what effects long term exposure to microgravity may have on the lungs. The focus is on measuring changes in the everness of gas exchange in the lungs, and on detecting changes in respiratory muscle strength. It allows astronauts to measure blood flow through the lungs, the ability of the lung to take up oxygen, and lung volumes. Each PuFF session includes five lung function tests, which involve breathing only cabin air. For each planned extravehicular (EVA) activity, a crew member performs a PuFF test within one week prior to the EVA. Following the EVA, those crew members perform another test to document the effect of exposure of the lungs to the low-pressure environment of the space suits. This experiment utilizes the Gas Analyzer System for Metabolic Analysis Physiology, or GASMAP, located in the Human Research Facility (HRF), along with a variety of other Puff equipment including a manual breathing valve, flow meter, pressure-flow module, pressure and volume calibration syringes, and disposable mouth pieces.
Trends in laboratory test volumes for Medicare Part B reimbursements, 2000-2010.
Shahangian, Shahram; Alspach, Todd D; Astles, J Rex; Yesupriya, Ajay; Dettwyler, William K
2014-02-01
Changes in reimbursements for clinical laboratory testing may help us assess the effect of various variables, such as testing recommendations, market forces, changes in testing technology, and changes in clinical or laboratory practices, and provide information that can influence health care and public health policy decisions. To date, however, there has been no report, to our knowledge, of longitudinal trends in national laboratory test use. To evaluate Medicare Part B-reimbursed volumes of selected laboratory tests per 10,000 enrollees from 2000 through 2010. Laboratory test reimbursement volumes per 10,000 enrollees in Medicare Part B were obtained from the Centers for Medicare & Medicaid Services (Baltimore, Maryland). The ratio of the most recent (2010) reimbursed test volume per 10,000 Medicare enrollees, divided by the oldest data (usually 2000) during this decade, called the volume ratio, was used to measure trends in test reimbursement. Laboratory tests with a reimbursement claim frequency of at least 10 per 10,000 Medicare enrollees in 2010 were selected, provided there was more than a 50% change in test reimbursement volume during the 2000-2010 decade. We combined the reimbursed test volumes for the few tests that were listed under more than one code in the Current Procedural Terminology (American Medical Association, Chicago, Illinois). A 2-sided Poisson regression, adjusted for potential overdispersion, was used to determine P values for the trend; trends were considered significant at P < .05. Tests with the greatest decrease in reimbursement volumes were electrolytes, digoxin, carbamazepine, phenytoin, and lithium, with volume ratios ranging from 0.27 to 0.64 (P < .001). Tests with the greatest increase in reimbursement volumes were meprobamate, opiates, methadone, phencyclidine, amphetamines, cocaine, and vitamin D, with volume ratios ranging from 83 to 1510 (P < .001). Although reimbursement volumes increased for most of the selected tests, other tests exhibited statistically significant downward trends in annual reimbursement volumes. The observed changes in reimbursement volumes may be explained by disease prevalence and severity, patterns of drug use, clinical or laboratory practices, and testing recommendations and guidelines, among others. These data may be useful to policy makers, health systems researchers, laboratory directors, and industry scientists to understand, address, and anticipate trends in laboratory testing in the Medicare population.
Yandrapu, Harathi; Elhanafi, Sherif; Chowdhury, Farhanaz; Liu, Jiayang; Onate, Eduardo J; Dwivedi, Alok; Othman, Mohamed O
2017-01-01
Endoscopic ultrasound (EUS) is commonly used to examine pancreaticobiliary disorders. We hypothesize that the introduction of EUS service may change the pattern and the complexity of endoscopic retrograde cholangiopancreatographies (ERCPs) performed. The aim of this study is to assess the impact of introducing EUS on the volume, success, and complexity of ERCP. This is a single-center retrospective data review of ERCP procedures done "before" and "after" the introduction of EUS (before EUS and after EUS). Patients' demographics, ERCP indications, types of sedation, therapeutic interventions, outcomes, complications, and complexity of ERCP were collected. The categorical and continuous variables were compared using Fisher's exact test and the unpaired t-test, respectively. Multivariable logistic regression analysis was used to compare ERCP outcomes. A total of 945 ERCPs performed over a 3-year period between January 2010 and January 2013 (411 and 534 in the "before EUS" and "after EUS" time periods, respectively) were included in this study. There was a 30% relative increase in the volume of ERCPs after the introduction of EUS. ERCP success rate was higher after the introduction of EUS, even after adjusting the complexity grade [odds ratio (OR) = 4.54, P = 0.001]. Significant increase in the complexity of ERCP was observed after the introduction of EUS service. The OR of performing grade 4 ERCP was 4.44 (P = 0.0005) after the introduction of EUS. The introduction of a new EUS service in our tertiary referral university medical center is associated with an increase in the volume, success, and complexity of ERCP procedures. EUS expertise may be valuable for better ERCP outcomes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aube, Christophe, E-mail: ChAube@chu-angers.fr; Schmidt, Diethard; Brieger, Jens
2007-02-15
Purpose. To determine, by means of an ex vivo study, the effect of different NaCl concentrations on the extent of coagulation obtained during radiofrequency (RF) ablation performed using a digitally controlled perfusion device. Method. Twenty-eight RF ablations were performed with 40 W for 10 min using continuous NaCl infusion in fresh excised bovine liver. For perfusion, NaCl concentrations ranging from 0 (demineralized water) to 25% were used. Temperature, the amount of energy, and the dimensions of thermal-induced white coagulation were assessed for each ablation. These parameters were compared using the nonparametric Mann-Whitney test. Correlations were calculated according to the Spearmanmore » test. Results. RF ablation performed with 0.9% to 25% concentrations of NaCl produced a mean volume of coagulation of 30.7 {+-} 3.8 cm{sup 3}, with a mean short-axis diameter of 3.6 {+-} 0.2 cm. The mean amount of energy was 21,895 {+-} 1,674 W and the mean temperature was 85.4 {+-} 12.8 deg. C. Volume of coagulation, short-axis diameter, and amount of energy did not differ significantly among NaCl concentrations (p > 0.5). A correlation was found between the NaCl concentration and the short-axis diameter of coagulation (r = 0.64) and between the NaCl concentration and the mean temperature (r = 0.67), but not between the NaCl concentration and volume of coagulation. Conclusion. In an ex vivo model, continuous perfusion with high NaCl concentrations does not significantly improve the volume of thermal-induced coagulation. This may be because the use of a low-power generator cannot sufficiently exploit the potential advantage of better tissue conductivity provided by NaCl perfusion.« less
Chelly, Mohamed Souhaiel; Hermassi, Souhail; Shephard, Roy J
2015-08-01
We studied the effect of supplementing normal in-season training by a 10-week lower limb plyometric training program (hurdle and depth jumping), examining measures of competitive potential (peak power output [PP], sprint running velocity, squat jump [SJ], countermovement jump [CMJ], drop jump [DJ], and lower limb muscle volume). The subjects (27 male track athletes, aged 11.9 ± 1.0 years; body mass: 39.1 ± 6.1 kg; height: 1.56 ± 0.02 m; body fat: 12.8 ± 4.4%) were randomly assigned between a control (normal training) group (C; n = 13) and an experimental group (E; n = 14) who also performed plyometric training 3 times per week. A force-velocity ergometer test determined PP and SJ, and an Optojump apparatus evaluated CMJ height and DJ (height and power). A multiple-5-bound test assessed horizontal jumping, and video-camera analyses over a 40-m sprint yielded velocities for the first step (VS), the first 5 m (V5m), and between 35 and 40 m (Vmax). Leg muscle volume was estimated anthropometrically. Experimental group showed gains relative to C in SJ height (p < 0.001); CMJ height (p < 0.01); DJ height and power relative to body mass (p < 0.01 for both); and all sprint velocities (p < 0.01 for VS and V(5m, p) ≤ 0.05 for Vmax). There was also a significant increase (p < 0.01) in thigh muscle volume, but leg muscle volume, thigh cross-sectional area, and PP remained unchanged. We conclude that adding plyometric training improved important components of athletic performance relative to standard in-season training in young runners.
Han, Doug Hyun; Lyoo, In Kyoon; Renshaw, Perry F
2012-04-01
Patients with on-line game addiction (POGA) and professional video game players play video games for extended periods of time, but experience very different consequences for their on-line game play. Brain regions consisting of anterior cingulate, thalamus and occpito-temporal areas may increase the likelihood of becoming a pro-gamer or POGA. Twenty POGA, seventeen pro-gamers, and eighteen healthy comparison subjects (HC) were recruited. All magnetic resonance imaging (MRI) was performed on a 1.5 Tesla Espree MRI scanner (SIEMENS, Erlangen, Germany). Voxel-wise comparisons of gray matter volume were performed between the groups using the two-sample t-test with statistical parametric mapping (SPM5). Compared to HC, the POGA group showed increased impulsiveness and perseverative errors, and volume in left thalamus gray matter, but decreased gray matter volume in both inferior temporal gyri, right middle occipital gyrus, and left inferior occipital gyrus, compared with HC. Pro-gamers showed increased gray matter volume in left cingulate gyrus, but decreased gray matter volume in left middle occipital gyrus and right inferior temporal gyrus compared with HC. Additionally, the pro-gamer group showed increased gray matter volume in left cingulate gyrus and decreased left thalamus gray matter volume compared with the POGA group. The current study suggests that increased gray matter volumes of the left cingulate gyrus in pro-gamers and of the left thalamus in POGA may contribute to the different clinical characteristics of pro-gamers and POGA. Copyright © 2012 Elsevier Ltd. All rights reserved.
Consistency in seroma contouring for partial breast radiotherapy: Impact of guidelines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wong, Elaine K.; Truong, Pauline T.; Kader, Hosam A.
2006-10-01
Purpose: Inconsistencies in contouring target structures can undermine the precision of conformal radiation therapy (RT) planning and compromise the validity of clinical trial results. This study evaluated the impact of guidelines on consistency in target volume contouring for partial breast RT planning. Methods and Materials: Guidelines for target volume definition for partial breast radiation therapy (PBRT) planning were developed by members of the steering committee for a pilot trial of PBRT using conformal external beam planning. In phase 1, delineation of the breast seroma in 5 early-stage breast cancer patients was independently performed by a 'trained' cohort of four radiationmore » oncologists who were provided with these guidelines and an 'untrained' cohort of four radiation oncologists who contoured without guidelines. Using automated planning software, the seroma target volume (STV) was expanded into a clinical target volume (CTV) and planning target volume (PTV) for each oncologist. Means and standard deviations were calculated, and two-tailed t tests were used to assess differences between the 'trained' and 'untrained' cohorts. In phase 2, all eight radiation oncologists were provided with the same contouring guidelines, and were asked to delineate the seroma in five new cases. Data were again analyzed to evaluate consistency between the two cohorts. Results: The 'untrained' cohort contoured larger seroma volumes and had larger CTVs and PTVs compared with the 'trained' cohort in three of five cases. When seroma contouring was performed after review of contouring guidelines, the differences in the STVs, CTVs, and PTVs were no longer statistically significant. Conclusion: Guidelines can improve consistency among radiation oncologists performing target volume delineation for PBRT planning.« less
Brain volume and cognitive function in patients with revascularized coronary artery disease.
Ottens, Thomas H; Hendrikse, Jeroen; Nathoe, Hendrik M; Biessels, Geert Jan; van Dijk, Diederik
2017-03-01
The pathogenesis of cognitive dysfunction in patients with CAD remains unclear. CAD is associated with brain atrophy and specific lesions. Detailed knowledge about the association of brain volume measured with MRI, and cognitive function in patients with CAD is lacking. We therefore investigated brain volume and cognitive function in patients with revascularized coronary artery disease (CAD), and controls without CAD. Brain MRI scans and cognitive tests from patients with CAD were compared with data from control subjects without CAD. Cognitive performance was assessed with the Rey Auditory Verbal Learning (short term memory) and Trailmaking (divided attention) tests. Multivariable regression analysis was used to study associations between CAD, brain volume and cognitive function. A total of 102 patients with CAD and 48 control subjects were included. Level of education and age were comparable between the groups. Compared with controls, patients with CAD had smaller total brain volume (expressed as fraction of intracranial volume) [%ICV, mean (SD), 0.78 (0.03) vs 0.80 (0.02), P=0.001] and larger volume of non-ventricular cerebrospinal fluid [%ICV, median (IQR) 0.19 (0.18 to 0.21) vs 0.18 (0.17 to 0.20), P=0.001]. Patients in the CAD group had poorer cognitive function [mean (SD) Z-score -0.16 (0.72) vs 0.41 (0.69), P<0.01]. Multivariable regression showed that CAD, higher age, lower level of education and greater cerebrospinal fluid volume were independent predictors of poorer cognitive function. CAD patients had a smaller total brain volume and poorer cognitive function than controls. Greater volume of cerebrospinal fluid was an independent predictor of poorer cognitive function. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Mongardon, Nicolas; Savary, Guillaume; Geri, Guillaume; El Bejjani, Marie-Rose; Silvera, Stéphane; Dumas, Florence; Charpentier, Julien; Pène, Frédéric; Mira, Jean-Paul; Cariou, Alain
2018-05-28
Adrenal gland volume is associated with survival in septic shock. As sepsis and post-cardiac arrest syndrome share many pathophysiological features, we assessed the association between adrenal gland volume measured by computerized tomography (CT)-scan and post-cardiac arrest shock and intensive care unit (ICU) mortality, in a large cohort of out-of-hospital cardiac arrest (OHCA) patients. We also investigated the association between adrenal hormonal function and both adrenal gland volume and outcomes. Prospective analysis of CT-scan performed at hospital admission in patients admitted after OHCA (2007-2012). A pair of blinded radiologist calculated manually adrenal gland volume. In a subgroup of patients, plasma cortisol was measured at admission and 60 min after a cosyntropin test. Factors associated with post-cardiac arrest shock and ICU mortality were identified using multivariate logistic regression. Among 775 patients admitted during this period after OHCA, 138 patients were included: 72 patients (52.2%) developed a post-cardiac arrest shock, and 98 patients (71.1%) died. In univariate analysis, adrenal gland volume was not different between patients with and without post-cardiac arrest shock: 10.6 and 11.3 cm 3 , respectively (p = 0.9) and between patients discharged alive or dead: 10.2 and 11.8 cm 3 , respectively (p = 0.4). Multivariate analysis confirmed that total adrenal gland volume was associated neither with post-cardiac arrest shock nor mortality. Neither baseline cortisol level nor delta between baseline and after cosyntropin test cortisol levels were associated with adrenal volume, post-cardiac arrest shock onset or mortality. After OHCA, adrenal gland volume is not associated with post-cardiac arrest shock onset or ICU mortality. Adrenal gland volume does not predict adrenal gland hormonal response. Copyright © 2018 Elsevier B.V. All rights reserved.
Goghari, Vina M; Macdonald, Angus W; Sponheim, Scott R
2011-11-01
Temporal lobe abnormalities and emotion recognition deficits are prominent features of schizophrenia and appear related to the diathesis of the disorder. This study investigated whether temporal lobe structural abnormalities were associated with facial emotion recognition deficits in schizophrenia and related to genetic liability for the disorder. Twenty-seven schizophrenia patients, 23 biological family members, and 36 controls participated. Several temporal lobe regions (fusiform, superior temporal, middle temporal, amygdala, and hippocampus) previously associated with face recognition in normative samples and found to be abnormal in schizophrenia were evaluated using volumetric analyses. Participants completed a facial emotion recognition task and an age recognition control task under time-limited and self-paced conditions. Temporal lobe volumes were tested for associations with task performance. Group status explained 23% of the variance in temporal lobe volume. Left fusiform gray matter volume was decreased by 11% in patients and 7% in relatives compared with controls. Schizophrenia patients additionally exhibited smaller hippocampal and middle temporal volumes. Patients were unable to improve facial emotion recognition performance with unlimited time to make a judgment but were able to improve age recognition performance. Patients additionally showed a relationship between reduced temporal lobe gray matter and poor facial emotion recognition. For the middle temporal lobe region, the relationship between greater volume and better task performance was specific to facial emotion recognition and not age recognition. Because schizophrenia patients exhibited a specific deficit in emotion recognition not attributable to a generalized impairment in face perception, impaired emotion recognition may serve as a target for interventions.
Hopkins, Heidi; Oyibo, Wellington; Luchavez, Jennifer; Mationg, Mary Lorraine; Asiimwe, Caroline; Albertini, Audrey; González, Iveth J; Gatton, Michelle L; Bell, David
2011-02-08
Malaria rapid diagnostic tests (RDTs) are increasingly used by remote health personnel with minimal training in laboratory techniques. RDTs must, therefore, be as simple, safe and reliable as possible. Transfer of blood from the patient to the RDT is critical to safety and accuracy, and poses a significant challenge to many users. Blood transfer devices were evaluated for accuracy and precision of volume transferred, safety and ease of use, to identify the most appropriate devices for use with RDTs in routine clinical care. Five devices, a loop, straw-pipette, calibrated pipette, glass capillary tube, and a new inverted cup device, were evaluated in Nigeria, the Philippines and Uganda. The 227 participating health workers used each device to transfer blood from a simulated finger-prick site to filter paper. For each transfer, the number of attempts required to collect and deposit blood and any spilling of blood during transfer were recorded. Perceptions of ease of use and safety of each device were recorded for each participant. Blood volume transferred was calculated from the area of blood spots deposited on filter paper. The overall mean volumes transferred by devices differed significantly from the target volume of 5 microliters (p < 0.001). The inverted cup (4.6 microliters) most closely approximated the target volume. The glass capillary was excluded from volume analysis as the estimation method used is not compatible with this device. The calibrated pipette accounted for the largest proportion of blood exposures (23/225, 10%); exposures ranged from 2% to 6% for the other four devices. The inverted cup was considered easiest to use in blood collection (206/226, 91%); the straw-pipette and calibrated pipette were rated lowest (143/225 [64%] and 135/225 [60%] respectively). Overall, the inverted cup was the most preferred device (72%, 163/227), followed by the loop (61%, 138/227). The performance of blood transfer devices varied in this evaluation of accuracy, blood safety, ease of use, and user preference. The inverted cup design achieved the highest overall performance, while the loop also performed well. These findings have relevance for any point-of-care diagnostics that require blood sampling.
NASA Technical Reports Server (NTRS)
Chie, C. M.
1984-01-01
The functional requirements for the performance, design, and testing for the prototype Automated Integrated Receive System (AIRS) to be demonstrated for the TDRSS S-Band Single Access Return Link are presented.
Code of Federal Regulations, 2011 CFR
2011-07-01
... the units of the emission standard, or 5 parts per million dry volume absolute value of the mean... zero and span adjustments). Any such periods that you do not collect data using the continuous...
Carlson, Matthew L; Sladen, Douglas P; Gurgel, Richard K; Tombers, Nicole M; Lohse, Christine M; Driscoll, Colin L
2018-01-01
To examine practice variance of cochlear implant candidacy assessment and off-label indications across centers in the United States. Cross-sectional survey of the American Neurotology Society (ANS). A total of 81 surveys were returned from ANS members who report regular involvement in cochlear implant care. Overall there was a broad distribution in age and clinical experience, with most respondents reporting ACGME accreditation in neurotology and employment at an academic center. The annual volume of cochlear implant surgeries varied considerably across centers.Seventy-eight percent of respondents performed cochlear implantation for at least one of the following indications within the last 2 years: profound hearing loss in children less than 12 months of age (35, 43%), children with asymmetrical hearing loss where at least one ear was better than performance cutoff for age (25, 31%), adults with asymmetrical hearing where at least one ear was better than the performance cutoff for adult criteria (49, 61%), single-sided deafness (37, 46%), and ipsilateral vestibular schwannoma (28, 35%). Centers with a higher annual implant volume more frequently performed off-label implantation in all queried populations (all, p≤0.001), and performed surgery on infants with congenital deafness at a younger age (p = 0.013), compared with centers with lower surgical volume.When surveyed regarding speech perception testing practices for adult candidacy assessment, 75 (100%) respondents who answered this question reported routine use of AzBio sentences, 42 (56%) CNC word scores, and 26 (35%) HINT testing; only 7 (9%) reported using BKB-SIN testing and 6 (8%) reported using CUNY scores. Fifty-one (68%) reported routine use of speech-in-noise testing to determine adult cochlear implant candidacy, 21 (28%) reported selective use only when patient scores were borderline in quiet, and 3 (4%) reported that their center does not currently use testing in noise for candidacy determination. Nineteen (26%) solely used +10 dB signal-to-noise ratio (SNR), 12 (16%) solely used +5 dB SNR, and 41 (55%) used both +10 and +5 dB SNR. Overall, 19% (N = 14) only perform unilateral implantation in the Medicare population, while 81% (N = 58) consider bilateral implantation. Significant variation in cochlear implant candidacy assessment and off-label implantation exists across centers and providers in the United States resulting in healthcare inequities. The high percentage of surgeons performing implantations for off-label or nontraditional indications reflects the overly restrictive and dated status of current implant guidelines. With greater adoption of more difficult speech perception testing in noise, careful clinical judgment is needed to maintain a favorable risk-benefit balance for prospective implant candidates.
A second-generation constrained reaction volume shock tube
NASA Astrophysics Data System (ADS)
Campbell, M. F.; Tulgestke, A. M.; Davidson, D. F.; Hanson, R. K.
2014-05-01
We have developed a shock tube that features a sliding gate valve in order to mechanically constrain the reactive test gas mixture to an area close to the shock tube endwall, separating it from a specially formulated non-reactive buffer gas mixture. This second-generation Constrained Reaction Volume (CRV) strategy enables near-constant-pressure shock tube test conditions for reactive experiments behind reflected shocks, thereby enabling improved modeling of the reactive flow field. Here we provide details of the design and operation of the new shock tube. In addition, we detail special buffer gas tailoring procedures, analyze the buffer/test gas interactions that occur on gate valve opening, and outline the size range of fuels that can be studied using the CRV technique in this facility. Finally, we present example low-temperature ignition delay time data to illustrate the CRV shock tube's performance.
Dual Tasking and Working Memory in Alcoholism: Relation to Frontocerebellar Circuitry
Chanraud, Sandra; Pitel, Anne-Lise; Rohlfing, Torsten; Pfefferbaum, Adolf; Sullivan, Edith V
2010-01-01
Controversy exists regarding the role of cerebellar systems in cognition and whether working memory compromise commonly marking alcoholism can be explained by compromise of nodes of corticocerebellar circuitry. We tested 17 alcoholics and 31 age-matched controls with dual-task, working memory paradigms. Interference tasks competed with verbal and spatial working memory tasks using low (three item) or high (six item) memory loads. Participants also underwent structural MRI to obtain volumes of nodes of the frontocerebellar system. On the verbal working memory task, both groups performed equally. On the spatial working memory with the high-load task, the alcoholic group was disproportionately more affected by the arithmetic distractor than were controls. In alcoholics, volumes of the left thalamus and left cerebellar Crus I volumes were more robust predictors of performance in the spatial working memory task with the arithmetic distractor than the left frontal superior cortex. In controls, volumes of the right middle frontal gyrus and right cerebellar Crus I were independent predictors over the left cerebellar Crus I, left thalamus, right superior parietal cortex, or left middle frontal gyrus of spatial working memory performance with tracking interference. The brain–behavior correlations suggest that alcoholics and controls relied on the integrity of certain nodes of corticocerebellar systems to perform these verbal and spatial working memory tasks, but that the specific pattern of relationships differed by group. The resulting brain structure–function patterns provide correlational support that components of this corticocerebellar system not typically related to normal performance in dual-task conditions may be available to augment otherwise dampened performance by alcoholics. PMID:20410871
Electrostatic Evaluation: SCAPE Suit Materials
NASA Technical Reports Server (NTRS)
Buhler, Charles; Calle, Carlos
2005-01-01
The surface resistivity tests are performed per the requirements of the ESD Association Standard Test Method ESD STM11.11*. These measurements are taken using a PRS-801 resistance system with an Electro Tech System (ETS) PRF-911 concentric ring resistance probe. The tests require a five pound weight on top of cylindrical electrodes and were conducted at both ambient and low humidity conditions. In order for materials to "pass" resistivity tests the surface of the materials must either be conductive or statically dissipative otherwise the materials "fail" ESD. Volume resistivity tests are also conducted to measure conductivity through the material as opposed to conductivity along the surface. These tests are conducted using the same PRS-801 resistance system with the Electro Tech System PRF-911 concentric ring resistance probe but are performed in accordance with ESD Association Standard Test Method ESD STM11.l2**.
Pettersen, Trond R; Mårtensson, Jan; Axelsson, Åsa; Jørgensen, Marianne; Strömberg, Anna; Thompson, David R; Norekvål, Tone M
2018-04-01
Cardiopulmonary resuscitation (CPR) remains a cornerstone in the treatment of cardiac arrest, and is directly linked to survival rates. Nurses are often first responders and need to be skilled in the performance of cardiopulmonary resuscitation. As cardiopulmonary resuscitation skills deteriorate rapidly, the purpose of this study was to investigate whether there was an association between participants' cardiopulmonary resuscitation training and their practical cardiopulmonary resuscitation test results. This comparative study was conducted at the 2014 EuroHeartCare meeting in Stavanger ( n=133) and the 2008 Spring Meeting on Cardiovascular Nursing in Malmö ( n=85). Participants performed cardiopulmonary resuscitation for three consecutive minutes CPR training manikins from Laerdal Medical®. Data were collected with a questionnaire on demographics and participants' level of cardiopulmonary resuscitation training. Most participants were female (78%) nurses (91%) from Nordic countries (77%), whose main role was in nursing practice (63%), and 71% had more than 11 years' experience ( n=218). Participants who conducted cardiopulmonary resuscitation training once a year or more ( n=154) performed better regarding ventilation volume than those who trained less (859 ml vs. 1111 ml, p=0.002). Those who had cardiopulmonary resuscitation training offered at their workplace ( n=161) also performed better regarding ventilation volume (889 ml vs. 1081 ml, p=0.003) and compression rate per minute (100 vs. 91, p=0.04) than those who had not. Our study indicates a positive association between participants' performance on the practical cardiopulmonary resuscitation test and the frequency of cardiopulmonary resuscitation training and whether cardiopulmonary resuscitation training was offered in the workplace. Large ventilation volumes were the most common error at both measuring points.
Giordano, Livia; Castagno, Roberta; Giorgi, Daniela; Piccinelli, Cristiano; Ventura, Leonardo; Segnan, Nereo; Zappa, Marco
2015-01-01
Together with the National centre for screening monitoring (ONS), GISMa supports annual collection of data on national breast screening activities. Aggregated data on implementation and performance are gathered through a standardized form to calculate process and impact indicators. Analyzed data belong to 153 local programmes in the period 2006-2011 (2006-2012 for participation rate only). During the whole period, Italian crude participation rate exceeded GISMa's acceptable standard (50%), even though a higher participation in northern and central Italy compared to southern Italy and Islands was observed. Time trend analysis of diagnostic indicators confirmed in 2011 an adequate quality of breast screening performance, especially at subsequent screening. Recall rate at initial screening did not reach the acceptable standard (<7%) and rose slightly over the period. On the contrary, a good performance was achieved at subsequent screening. The same trend was followed by the overall detection rate and positive predictive value. They both showed a progressive reduction (from 6.2‰ in 2006 to 4.5‰ in 2011 for DR and from 8.0% in 2006 to 5.2% in 2011 for PPV, respectively) at initial screening and a good, stable trend at subsequent screening. Activity volume analysis shows that in programmes with greater activity (test/year ≥10,000) RR at both initial and subsequent screening has a better performance. This is also true for DR and PPV where programmes with high volumes of activity do better, especially when compared with those that interpret fewer than 5,000 mammograms per year. In spite of a few limits, these results are reassuring, and they reward the efforts made by screening professionals. It is therefore important to continue to monitor screening indicators and suggest, test, and evaluate new strategies for continuous improvement.
Human Performance Review of the Retail Repair Parts Supply System. Volume II.
1980-02-01
transsexual adults were tested by LaTorre, Gossmann, and Piper (1976) on the Embedded-figures Test. It was found that the males were more field independent...than females, and that the transsexuals were as field dependent as the females. In this case the male trans- sexuals behaved like the female group in...1976. LaTorre, R. A., Gossmann, I., & Piper, W. E. Cognitive style, hemi- spheric specialization, and tested abilities of transsexuals and
ERIC Educational Resources Information Center
Durden, William G.
Although performance on the Scholastic Aptitude Test (SAT) and the American College Test Program (ACT) indicates that Wisconsin's students are superior to those of other states, a more thorough assessment reveals that the state does not compare well with its neighbors either on the general level of academic preparedness or in efforts to develop…
Hermassi, Souhail; Chelly, Mohamed Souhaiel; Wagner, Herbert; Fieseler, Georg; Schulze, Stephan; Delank, Karl-Stefan; Shephard, Roy J; Schwesig, René
2018-02-14
The purpose of this study was to examine relationships between lower body muscular strength, anthropometric characteristics and several measures of explosive performance in elite team-handball players. 22 male elite team-handball players (age: 19.1 ± 1.7 years) were studied during the competitive season. Standard anthropometric and body composition measures included body mass index, lower limb and thigh muscle volume, and body fat percentage. Maximal leg strength was determined by a one-repetition maximum (1-RM) half back-squat. Vertical jump performance was assessed using a squat jump (SJ) and a counter movement jump (CMJ). Repeated shuttle-sprint ability (RSA) was tested by 6 (2 × 15 m) shuttle sprints with 20 s of active recovery intervals. The best time in a single shuttle sprint (30m; RSA best ), fastest total time (RSA TT ) and RSA test performance decrement (RSA dec ) were recorded. Agility was measured using a modified T-half test (MAT). Throwing velocities of jump shooting and 3-step throwing were recorded by digital video camera. The explained variance of 1-RM half-back-squats ranged from 0.2 % (RSA% Fatigue Index) to 70.1 % (CMJ). Four out of 8 variables (RSA Best Time, CMJ, SJ, throwing velocity of jump shoot) demonstrated an r 2 > 0.5. Jump performances seemed closely related to 1-RM half-back-squats. Furthermore, 1-RM half-back-squats were positively correlated with leg and thigh muscle volumes (r = 0.652, r = 0.768). The anthropometric characteristics and some physical performance tests are closely related to the maximal strength performance of handball players. Coaches should focus on maximal strength training programs for the lower limbs when seeking improvements in the throwing velocity and jump performance of handball players. © Georg Thieme Verlag KG Stuttgart · New York.
Cai, Wenli; Lee, June-Goo; Fikry, Karim; Yoshida, Hiroyuki; Novelline, Robert; de Moya, Marc
2012-07-01
It is commonly believed that the size of a pneumothorax is an important determinant of treatment decision, in particular regarding whether chest tube drainage (CTD) is required. However, the volumetric quantification of pneumothoraces has not routinely been performed in clinics. In this paper, we introduced an automated computer-aided volumetry (CAV) scheme for quantification of volume of pneumothoraces in chest multi-detect CT (MDCT) images. Moreover, we investigated the impact of accurate volume of pneumothoraces in the improvement of the performance in decision-making regarding CTD in the management of traumatic pneumothoraces. For this purpose, an occurrence frequency map was calculated for quantitative analysis of the importance of each clinical parameter in the decision-making regarding CTD by a computer simulation of decision-making using a genetic algorithm (GA) and a support vector machine (SVM). A total of 14 clinical parameters, including volume of pneumothorax calculated by our CAV scheme, was collected as parameters available for decision-making. The results showed that volume was the dominant parameter in decision-making regarding CTD, with an occurrence frequency value of 1.00. The results also indicated that the inclusion of volume provided the best performance that was statistically significant compared to the other tests in which volume was excluded from the clinical parameters. This study provides the scientific evidence for the application of CAV scheme in MDCT volumetric quantification of pneumothoraces in the management of clinically stable chest trauma patients with traumatic pneumothorax. Copyright © 2012 Elsevier Ltd. All rights reserved.
Morales, Jose; Buscà, Bernat; Solana-Tramunt, Mònica; Miró, Adrià
2015-12-01
The latest findings on the ergogenic effects of a dentistry-design, bite-aligning mouthpiece require additional research to assess its impact on anaerobic ability and ventilatory parameters. This paper was aimed at determining the ergogenic acute effects of wearing a custom-made mouthpiece on oral airflow dynamics, 30-s Wingate Anaerobic Test performance parameters. Twenty-eight healthy and physically-active male subjects (age: 24.50 ± 3.32, height: 181.34 ± 7.4, weight: 78.14 ± 8.21), were voluntarily studied. The subjects were first briefed on the test protocols, and then performed the 30s Wingate test and Spirometer test. The experimental trials were performed in a random counterbalanced order. We evaluate maximum expiratory volume (VEmax L min(-1)), mean power (W kg(-1)), peak power (W kg(-1)), time to peak (s), rate to fatigue (Ws(-1)) and lactate production (mMol L(-1)), rate of perceived exertion (RPE). There were significant differences between mouthguard and no-mouthguard conditions in mean power (W kg(-1)), peak power (W kg(-1)), time to peak (s), and rate to fatigue (Ws(-1)) for the 30-s Wingate Anaerobic Test. Significantly lower lactate production (mMol L(-1)) was observed, in mouthguard condition but no significant differences were found in RPE. In airflow dynamics, the VEmax L min(-1) was significantly higher when comparing the mouthguard and the no mouthguard conditions in both forced and unforced conditions. In conclusion, wearing a customized mouthguard improves anaerobic ability and increases forced expiratory volume. This study will help practitioners improve athlete's performance in anaerobic activities where high intensity action might provoke jaw-clenching, contributing in reductions of lactate and fatigue, and improving ventilatory parameters. Copyright © 2015 Elsevier B.V. All rights reserved.
Disability-Specific Atlases of Gray Matter Loss in Relapsing-Remitting Multiple Sclerosis.
MacKenzie-Graham, Allan; Kurth, Florian; Itoh, Yuichiro; Wang, He-Jing; Montag, Michael J; Elashoff, Robert; Voskuhl, Rhonda R
2016-08-01
Multiple sclerosis (MS) is characterized by progressive gray matter (GM) atrophy that strongly correlates with clinical disability. However, whether localized GM atrophy correlates with specific disabilities in patients with MS remains unknown. To understand the association between localized GM atrophy and clinical disability in a biology-driven analysis of MS. In this cross-sectional study, magnetic resonance images were acquired from 133 women with relapsing-remitting MS and analyzed using voxel-based morphometry and volumetry. A regression analysis was used to determine whether voxelwise GM atrophy was associated with specific clinical deficits. Data were collected from June 28, 2007, to January 9, 2014. Voxelwise correlation of GM change with clinical outcome measures (Expanded Disability Status Scale and Multiple Sclerosis Functional Composite scores). Among the 133 female patients (mean [SD] age, 37.4 [7.5] years), worse performance on the Multiple Sclerosis Functional Composite correlated with voxelwise GM volume loss in the middle cingulate cortex (P < .001) and a cluster in the precentral gyrus bilaterally (P = .004). In addition, worse performance on the Paced Auditory Serial Addition Test correlated with volume loss in the auditory and premotor cortices (P < .001), whereas worse performance on the 9-Hole Peg Test correlated with GM volume loss in Brodmann area 44 (Broca area; P = .02). Finally, voxelwise GM loss in the right paracentral lobulus correlated with bowel and bladder disability (P = .03). Thus, deficits in specific clinical test results were directly associated with localized GM loss in clinically eloquent locations. These biology-driven data indicate that specific disabilities in MS are associated with voxelwise GM loss in distinct locations. This approach may be used to develop disability-specific biomarkers for use in future clinical trials of neuroprotective treatments in MS.
Grey matter damage and overall cognitive impairment in primary progressive multiple sclerosis.
Tur, C; Penny, S; Khaleeli, Z; Altmann, D R; Cipolotti, L; Ron, M; Thompson, A J; Ciccarelli, O
2011-11-01
To identify associations between cognitive impairment and imaging measures in a cross-sectional study of patients with primary progressive multiple sclerosis (PPMS). Neuropsychological tests were administered to 27 patients with PPMS and 31 controls. Patients underwent brain conventional magnetic resonance imaging (MRI) sequences, volumetric scans and magnetization transfer (MT) imaging; MT ratio (MTR) parameters, grey matter (GM) and normal-appearing white matter (NAWM) volumes, and WM T2 lesion load (T2LL) were obtained. In patients, multiple linear regression models identified the imaging measure associated with the abnormal cognitive tests independently from the other imaging variables. Partial correlation coefficients (PCC) were reported. Patients performed worse on tests of attention/speed of visual information processing, delayed verbal memory, and executive function, and had a worse overall cognitive performance index, when compared with controls. In patients, a lower GM peak location MTR was associated with worse overall cognitive performance (p < 0.001, PCC = 0.77). GM mean and peak height MTR showed the strongest association with the estimated verbal intelligence quotient (IQ) decline (p < 0.001, PCC = -0.62), and executive function (p < 0.001, PCC = 0.79). NAWM volume was associated with attention/speed of visual information processing (p < 0.001, PCC = 0.74), while T2LL was associated with delayed verbal memory (p = 0.007, PCC = -0.55). The finding of strong associations between GM MTR, NAWM volume and T2LL and specific cognitive impairments suggests that models that predict cognitive impairment in PPMS should include comprehensive MRI assessments of both GM and WM. However, GM MTR appears to be the main correlate of overall cognitive dysfunction, underlining the role of abnormal GM integrity in determining cognitive impairment in PPMS.
NASA Astrophysics Data System (ADS)
Jung, Hojung; Singh, Gurpreet; Espinoza, D. Nicolas; Wheeler, Mary F.
2018-02-01
Subsurface CO2 injection and storage alters formation pressure. Changes of pore pressure may result in fault reactivation and hydraulic fracturing if the pressure exceeds the corresponding thresholds. Most simulation models predict such thresholds utilizing relatively homogeneous reservoir rock models and do not account for CO2 dissolution in the brine phase to calculate pore pressure evolution. This study presents an estimation of reservoir capacity in terms of allowable injection volume and rate utilizing the Frio CO2 injection site in the coast of the Gulf of Mexico as a case study. The work includes laboratory core testing, well-logging data analyses, and reservoir numerical simulation. We built a fine-scale reservoir model of the Frio pilot test in our in-house reservoir simulator IPARS (Integrated Parallel Accurate Reservoir Simulator). We first performed history matching of the pressure transient data of the Frio pilot test, and then used this history-matched reservoir model to investigate the effect of the CO2 dissolution into brine and predict the implications of larger CO2 injection volumes. Our simulation results -including CO2 dissolution- exhibited 33% lower pressure build-up relative to the simulation excluding dissolution. Capillary heterogeneity helps spread the CO2 plume and facilitate early breakthrough. Formation expansivity helps alleviate pore pressure build-up. Simulation results suggest that the injection schedule adopted during the actual pilot test very likely did not affect the mechanical integrity of the storage complex. Fault reactivation requires injection volumes of at least about sixty times larger than the actual injected volume at the same injection rate. Hydraulic fracturing necessitates much larger injection rates than the ones used in the Frio pilot test. Tested rock samples exhibit ductile deformation at in-situ effective stresses. Hence, we do not expect an increase of fault permeability in the Frio sand even in the presence of fault reactivation.
NASA Astrophysics Data System (ADS)
López, J.; Hernández, J.; Gómez, P.; Faura, F.
2018-02-01
The VOFTools library includes efficient analytical and geometrical routines for (1) area/volume computation, (2) truncation operations that typically arise in VOF (volume of fluid) methods, (3) area/volume conservation enforcement (VCE) in PLIC (piecewise linear interface calculation) reconstruction and(4) computation of the distance from a given point to the reconstructed interface. The computation of a polyhedron volume uses an efficient formula based on a quadrilateral decomposition and a 2D projection of each polyhedron face. The analytical VCE method is based on coupling an interpolation procedure to bracket the solution with an improved final calculation step based on the above volume computation formula. Although the library was originally created to help develop highly accurate advection and reconstruction schemes in the context of VOF methods, it may have more general applications. To assess the performance of the supplied routines, different tests, which are provided in FORTRAN and C, were implemented for several 2D and 3D geometries.
Ernstbrunner, Matthäus; Kostner, Lisa; Kimberger, Oliver; Wabel, Peter; Säemann, Marcus; Markstaller, Klaus; Fleischmann, Edith; Kabon, Barbara; Hecking, Manfred
2014-01-01
Background Technically assisted assessment of volume status before surgery may be useful to direct intraoperative fluid administration. We therefore tested a recently developed whole-body bioimpedance spectroscopy device to determine pre- to postoperative fluid distribution. Methods Using a three-compartment physiologic tissue model, the body composition monitor (BCM, Fresenius Medical Care, Germany) measures total body fluid volume, extracellular volume, intracellular volume and fluid overload as surplus or deficit of ‘normal’ extracellular volume. BCM-measurements were performed before and after standardized general anaesthesia for gynaecological procedures (laparotomies, laparoscopies and vaginal surgeries). BCM results were blinded to the attending anaesthesiologist and data analysed using the 2-sided, paired Student’s t-test and multiple linear regression. Results In 71 females aged 45±15 years with body weight 67±13 kg and duration of anaesthesia 154±68 min, pre- to postoperative fluid overload increased from −0.7±1.1 L to 0.1±1.0 L, corresponding to −5.1±7.5% and 0.8±6.7% of normal extracellular volume, respectively (both p<0.001), after patients had received 1.9±0.9 L intravenous crystalloid fluid. Perioperative urinary excretion was 0.4±0.3 L. The increase in extracellular volume was paralleled by an increase in total body fluid volume, while intracellular volume increased only slightly and without reaching statistical significance (p = 0.15). Net perioperative fluid balance (administered fluid volume minus urinary excretion) was significantly associated with change in extracellular volume (r2 = 0.65), but was not associated with change in intracellular volume (r2 = 0.01). Conclusions Routine intraoperative fluid administration results in a significant, and clinically meaningful increase in the extracellular compartment. BCM-measurements yielded plausible results and may become useful to guide intraoperative fluid therapy in future studies. PMID:25360698
Paratransit Vehicle Test and Evaluation : Volume 3. Handling Tests.
DOT National Transportation Integrated Search
1978-06-01
A series of tests and evaluations of two prototype vehicles for paratransit were conducted. This volume (Volume III) presents the test procedures and results of the handling test series. The test determined the steering and handling characteristics o...
Neuropsychological Investigation of Motor Impairments in Autism
Duffield, Tyler; Trontel, Haley; Bigler, Erin D.; Froehlich, Alyson; Prigge, Molly B.; Travers, Brittany; Green, Ryan R.; Cariello, Annahir N.; Cooperrider, Jason; Nielsen, Jared; Alexander, Andrew; Anderson, Jeffrey; Fletcher, P. Thomas; Lange, Nicholas; Zielinski, Brandon; Lainhart, Janet
2013-01-01
It is unclear how standardized neuropsychological measures of motor function relate to brain volumes of motor regions in autism spectrum disorder (ASD). An all male sample composed of 59 ASD and 30 controls (ages 5–33 years) completed three measures of motor function: strength of grip (SOG), finger tapping test (FTT), and grooved peg-board test (GPT). Likewise, all participants underwent magnetic resonance imaging with region of interest (ROI) volumes obtained to include the following regions: motor cortex (pre-central gyrus), somatosensory cortex (post-central gyrus), thalamus, basal ganglia, cerebellum and caudal middle frontal gyrus. These traditional neuropsychological measures of motor function are assumed to differ in motor complexity with GPT requiring the most followed by FTT and SOG. Performance by ASD participants on the GPT and FTT differed significantly from controls, with the largest effect size differences observed on the more complex GPT task. Differences on the SOG task between the two groups were non-significant. Since more complex motor tasks tap more complex networks, poorer GPT performance by those with ASD may reflect less efficient motor networks. There was no gross pathology observed in classic motor areas of the brain in ASD, as region of interest (ROI) volumes did not differ, but FTT was negatively related to motor cortex volume in ASD. The results suggest a hierarchical motor disruption in ASD, with difficulties evident only in more complex tasks as well as a potential anomalous size-function relation in motor cortex in ASD. PMID:23985036
NASA Technical Reports Server (NTRS)
1974-01-01
System design and performance of the Skylab Airlock Module and Payload Shroud are presented for the communication and caution and warning systems. Crew station and storage, crew trainers, experiments, ground support equipment, and system support activities are also reviewed. Other areas documented include the reliability and safety programs, test philosophy, engineering project management, and mission operations support.
MSFC Skylab Orbital Workshop, volume 3. [design and development of waste disposal system
NASA Technical Reports Server (NTRS)
1974-01-01
The waste management system for the Skylab Orbital Workshop is discussed. The general requirements of the system are presented. Illustrations of the components of the system are provided. Data concerning maximum expected performance capabilities are developed. The results of performance tests on the system components are reported. Emphasis is placed on the human factors engineering aspects of the system.
ERIC Educational Resources Information Center
Brown, William R.; And Others
An evaluation was conducted of minority (Black, Hispanic, Asian, American Indian) and female performance in the Army's Initial Entry Rotary Wing flight training program. Each minority group was compared to a matched sample of majority students. The groups were matched on several test scores, education level, age, rank, and source of entry. The…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1985-01-01
Literature summarizing a study on the Saudi Arabian solar controlled environment agriculture system is presented. Specifications and performance requirements for the system components are revealed. Detailed performance and cost analyses are used to determine the optimum design. A preliminary design of an engineering field test is included. Some weather data are provided for Riyadh, Saudi Arabia. (BCS)
ERIC Educational Resources Information Center
Khan, Wasi Z.; Al Zubaidy, Sarim
2017-01-01
The variance in students' academic performance in a civilian institute and in a military technological institute could be linked to the environment of the competition available to the students. The magnitude of talent, domain of skills and volume of efforts students put are identical in both type of institutes. The significant factor is the…
NASA Technical Reports Server (NTRS)
1973-01-01
The heat transfer characteristics of various materials used for the thermal insulation of spacecraft are discussed. Techniques for conducting thermal performance analysis, structural performance analysis, and dynamic analysis are described. Processes for producing and finishing the materials are explained. The methods for determining reliability, system safety, materials tests, and design effectiveness are explained.
Similarity in Bilateral Isolated Internal Orbital Fractures.
Chen, Hung-Chang; Cox, Jacob T; Sanyal, Abanti; Mahoney, Nicholas R
2018-04-13
In evaluating patients sustaining bilateral isolated internal orbital fractures, the authors have observed both similar fracture locations and also similar expansion of orbital volumes. In this study, we aim to investigate if there is a propensity for the 2 orbits to fracture in symmetrically similar patterns when sustaining similar trauma. A retrospective chart review was performed studying all cases at our institution of bilateral isolated internal orbital fractures involving the medial wall and/or the floor at the time of presentation. The similarity of the bilateral fracture locations was evaluated using the Fisher's exact test. The bilateral expanded orbital volumes were analyzed using the Wilcoxon signed-rank test to assess for orbital volume similarity. Twenty-four patients with bilateral internal orbital fractures were analyzed for fracture location similarity. Seventeen patients (70.8%) had 100% concordance in the orbital subregion fractured, and the association between the right and the left orbital fracture subregion locations was statistically significant (P < 0.0001). Fifteen patients were analyzed for orbital volume similarity. The average orbital cavity volume was 31.2 ± 3.8 cm on the right and 32.0 ± 3.7 cm on the left. There was a statistically significant difference between right and left orbital cavity volumes (P = 0.0026). The data from this study suggest that an individual who suffers isolated bilateral internal orbital fractures has a statistically significant similarity in the location of their orbital fractures. However, there does not appear to be statistically significant similarity in the expansion of the orbital volumes in these patients.
LLCEDATA and LLCECALC for Windows version 1.0, Volume 3: Software verification and validation
DOE Office of Scientific and Technical Information (OSTI.GOV)
McFadden, J.G.
1998-09-04
LLCEDATA and LLCECALC for Windows are user-friendly computer software programs that work together to determine the proper waste designation, handling, and disposition requirements for Long Length Contaminated Equipment (LLCE). LLCEDATA reads from a variety of data bases to produce an equipment data file(EDF) that represents a snapshot of both the LLCE and the tank from which it originates. LLCECALC reads the EDF and the gamma assay file (AV2) that is produced by the flexible Receiver Gamma Energy Analysis System. LLCECALC performs corrections to the AV2 file as it is being read and characterizes the LLCE. Both programs produce a varietymore » of reports, including a characterization report and a status report. The status report documents each action taken by the user, LLCEDATA, and LLCECALC. Documentation for LLCEDATA and LLCECALC for Windows is available in three volumes. Volume 1 is a user`s manual, which is intended as a quick reference for both LLCEDATA and LLCECALC. Volume 2 is a technical manual, which discusses system limitations and provides recommendations to the LLCE process. Volume 3 documents LLCEDATA and LLCECALC`s verification and validation. Two of the three installation test cases, from Volume 1, are independently confirmed. Data bases used in LLCEDATA are verified and referenced. Both phases of LLCECALC process gamma and characterization, are extensively tested to verify that the methodology and algorithms used are correct.« less