Sample records for performance tests performance

  1. Understanding protocol performance: impact of test performance.

    PubMed

    Turner, Robert G

    2013-01-01

    This is the second of two articles that examine the factors that determine protocol performance. The objective of these articles is to provide a general understanding of protocol performance that can be used to estimate performance, establish limits on performance, decide if a protocol is justified, and ultimately select a protocol. The first article was concerned with protocol criterion and test correlation. It demonstrated the advantages and disadvantages of different criterion when all tests had the same performance. It also examined the impact of increasing test correlation on protocol performance and the characteristics of the different criteria. To examine the impact on protocol performance when individual tests in a protocol have different performance. This is evaluated for different criteria and test correlations. The results of the two articles are combined and summarized. A mathematical model is used to calculate protocol performance for different protocol criteria and test correlations when there are small to large variations in the performance of individual tests in the protocol. The performance of the individual tests that make up a protocol has a significant impact on the performance of the protocol. As expected, the better the performance of the individual tests, the better the performance of the protocol. Many of the characteristics of the different criteria are relatively independent of the variation in the performance of the individual tests. However, increasing test variation degrades some criteria advantages and causes a new disadvantage to appear. This negative impact increases as test variation increases and as more tests are added to the protocol. Best protocol performance is obtained when individual tests are uncorrelated and have the same performance. In general, the greater the variation in the performance of tests in the protocol, the more detrimental this variation is to protocol performance. Since this negative impact is increased as more tests are added to the protocol, greater test variation indicates using fewer tests in the protocol. American Academy of Audiology.

  2. 40 CFR 60.4400 - How do I conduct the initial and subsequent performance tests, regarding NOX?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... subsequent performance tests, regarding NOX? 60.4400 Section 60.4400 Protection of Environment ENVIRONMENTAL... Standards of Performance for Stationary Combustion Turbines Performance Tests § 60.4400 How do I conduct the initial and subsequent performance tests, regarding NOX? (a) You must conduct an initial performance test...

  3. 40 CFR 60.4400 - How do I conduct the initial and subsequent performance tests, regarding NOX?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... subsequent performance tests, regarding NOX? 60.4400 Section 60.4400 Protection of Environment ENVIRONMENTAL... Standards of Performance for Stationary Combustion Turbines Performance Tests § 60.4400 How do I conduct the initial and subsequent performance tests, regarding NOX? (a) You must conduct an initial performance test...

  4. 40 CFR 60.4400 - How do I conduct the initial and subsequent performance tests, regarding NOX?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... subsequent performance tests, regarding NOX? 60.4400 Section 60.4400 Protection of Environment ENVIRONMENTAL... Standards of Performance for Stationary Combustion Turbines Performance Tests § 60.4400 How do I conduct the initial and subsequent performance tests, regarding NOX? (a) You must conduct an initial performance test...

  5. 40 CFR 60.4400 - How do I conduct the initial and subsequent performance tests, regarding NOX?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... subsequent performance tests, regarding NOX? 60.4400 Section 60.4400 Protection of Environment ENVIRONMENTAL... Standards of Performance for Stationary Combustion Turbines Performance Tests § 60.4400 How do I conduct the initial and subsequent performance tests, regarding NOX? (a) You must conduct an initial performance test...

  6. 40 CFR 60.4400 - How do I conduct the initial and subsequent performance tests, regarding NOX?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... subsequent performance tests, regarding NOX? 60.4400 Section 60.4400 Protection of Environment ENVIRONMENTAL... Standards of Performance for Stationary Combustion Turbines Performance Tests § 60.4400 How do I conduct the initial and subsequent performance tests, regarding NOX? (a) You must conduct an initial performance test...

  7. Electrical Evaluation of RCA MWS5001D Random Access Memory, Volume 1

    NASA Technical Reports Server (NTRS)

    Klute, A.

    1979-01-01

    Electrical characterization and qualification tests were performed on the RCA MWS5001D, 1024 by 1-bit, CMOS, random access memory. Characterization tests were performed on five devices. The tests included functional tests, AC parametric worst case pattern selection test, determination of worst-case transition for setup and hold times and a series of schmoo plots. The qualification tests were performed on 32 devices and included a 2000 hour burn in with electrical tests performed at 0 hours and after 168, 1000, and 2000 hours of burn in. The tests performed included functional tests and AC and DC parametric tests. All of the tests in the characterization phase, with the exception of the worst-case transition test, were performed at ambient temperatures of 25, -55 and 125 C. The worst-case transition test was performed at 25 C. The preburn in electrical tests were performed at 25, -55, and 125 C. All burn in endpoint tests were performed at 25, -40, -55, 85, and 125 C.

  8. Understanding pretest and posttest reactions to cognitive ability and personality tests.

    PubMed

    Chan, D; Schmitt, N; Sacco, J M; DeShon, R P

    1998-06-01

    To understand the nature of test reactions and their relationship to test performance, the relationships among belief in tests, pretest reactions, test performance, and posttest reactions were modeled for cognitive ability and personality tests. Results from structural equation models that were fitted to responses from 197 undergraduate examinees supported the hypothesized relationships. On the cognitive ability test, pretest reactions affected test performance and mediated the relationship between belief in tests and test performance. Test performance affected posttest reactions even after taking into account the effect of pretest reactions. On the personality test, belief in tests affected pretest and posttest reactions, but the three variables were unrelated to test performance (Conscientiousness scores). Conceptual, methodological, and practical implications of the findings are discussed in the context of research on test reactions and test performance.

  9. 40 CFR Table 6 to Subpart Wwww of... - Basic Requirements for Performance Tests, Performance Evaluations, and Design Evaluations for New...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control... Performance Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control Devices As required in § 63.5850 you must conduct performance tests, performance evaluations, and...

  10. 40 CFR Table 6 to Subpart Wwww of... - Basic Requirements for Performance Tests, Performance Evaluations, and Design Evaluations for New...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control... Performance Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control Devices As required in § 63.5850 you must conduct performance tests, performance evaluations, and...

  11. 40 CFR Table 6 to Subpart Wwww of... - Basic Requirements for Performance Tests, Performance Evaluations, and Design Evaluations for New...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control... Performance Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control Devices As required in § 63.5850 you must conduct performance tests, performance evaluations, and...

  12. Students' Geographic Knowledge and Skills in Different Kinds of Tests: Multiple-Choice versus Performance Assessment.

    ERIC Educational Resources Information Center

    Kon, Jane Heckley; Martin-Kniep, Giselle O.

    1992-01-01

    Describes a case study to determine whether performance tests are a feasible alternative to multiple-choice tests. Examines the difficulties of administering and scoring performance assessments. Explains that the study employed three performance tests and one multiple-choice test. Concludes that performance test administration and scoring was no…

  13. 40 CFR 63.504 - Additional requirements for performance testing.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Additional requirements for performance... Additional requirements for performance testing. (a) Performance testing shall be conducted in accordance.... Sections 63.484 through 63.501 also contain specific testing requirements. (1) Performance tests shall be...

  14. 40 CFR 610.63 - Performance tests.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Performance tests. 610.63 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.63 Performance tests. The effect of a device on a vehicle's performance will be determined by performing wide-open-throttle...

  15. 40 CFR 60.8 - Performance tests.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Performance tests. 60.8 Section 60.8... PERFORMANCE FOR NEW STATIONARY SOURCES General Provisions § 60.8 Performance tests. (a) Except as specified in... conduct performance test(s) and furnish the Administrator a written report of the results of such...

  16. 40 CFR 63.7 - Performance testing requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Performance testing requirements. (a) Applicability and performance test dates. (1) The applicability of this... or operator of the affected source must perform such tests within 180 days of the compliance date for... standard initially, the owner or operator shall conduct a second performance test within 3 years and 180...

  17. 40 CFR Table 6 to Subpart Wwww of... - Basic Requirements for Performance Tests, Performance Evaluations, and Design Evaluations for New...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control Devices As required in § 63.5850 you must conduct performance tests, performance evaluations, and design...

  18. 40 CFR Table 6 to Subpart Wwww of... - Basic Requirements for Performance Tests, Performance Evaluations, and Design Evaluations for New...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control Devices As required in § 63.5850 you must conduct performance tests, performance evaluations, and design...

  19. Functional performance testing for power and return to sports.

    PubMed

    Manske, Robert; Reiman, Michael

    2013-05-01

    Functional performance testing of athletes can determine physical limitations that may affect sporting activities. Optimal functional performance testing simulates the athlete's activity. A Medline search from 1960 to 2012 was implemented with the keywords functional testing, functional impairment testing, and functional performance testing in the English language. Each author also undertook independent searches of article references. Functional performance tests can bridge the gap between general physical tests and full, unrestricted athletic activity.

  20. Development, construct validity and test-retest reliability of a field-based wheelchair mobility performance test for wheelchair basketball.

    PubMed

    de Witte, Annemarie M H; Hoozemans, Marco J M; Berger, Monique A M; van der Slikke, Rienk M A; van der Woude, Lucas H V; Veeger, Dirkjan H E J

    2018-01-01

    The aim of this study was to develop and describe a wheelchair mobility performance test in wheelchair basketball and to assess its construct validity and reliability. To mimic mobility performance of wheelchair basketball matches in a standardised manner, a test was designed based on observation of wheelchair basketball matches and expert judgement. Forty-six players performed the test to determine its validity and 23 players performed the test twice for reliability. Independent-samples t-tests were used to assess whether the times needed to complete the test were different for classifications, playing standards and sex. Intraclass correlation coefficients (ICC) were calculated to quantify reliability of performance times. Males performed better than females (P < 0.001, effect size [ES] = -1.26) and international men performed better than national men (P < 0.001, ES = -1.62). Performance time of low (≤2.5) and high (≥3.0) classification players was borderline not significant with a moderate ES (P = 0.06, ES = 0.58). The reliability was excellent for overall performance time (ICC = 0.95). These results show that the test can be used as a standardised mobility performance test to validly and reliably assess the capacity in mobility performance of elite wheelchair basketball athletes. Furthermore, the described methodology of development is recommended for use in other sports to develop sport-specific tests.

  1. Small passenger car transmission test: Dodge Omni A-404 transmission

    NASA Technical Reports Server (NTRS)

    Bujold, M. P.

    1980-01-01

    The small passenger car transmission test was initiated to supply electric vehicle manufacturers with technical information regarding the performance of commercially available transmissions. This transmission was tested in accordance with a passenger car automatic transmission test code (SAE J65lb) which required drive performance, coast performance, and no load test conditions. Under these test conditions, the transmission attained maximum efficiencies in the mid eighty percent range for both drive performance test and coast performance tests.

  2. Quiet Clean Short-Haul Experimental Engine (QCSEE) Over-The-Wing (OTW) propulsion system test report. Volume 2: Aerodynamics and performance. [engine performance tests to define propulsion system performance on turbofan engines

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The design and testing of the over the wing engine, a high bypass, geared turbofan engine, are discussed. The propulsion system performance is examined for uninstalled performance and installed performance. The fan aerodynamic performance and the D nozzle and reverser thrust performance are evaluated.

  3. Small passenger car transmission test; Chevrolet LUV transmission

    NASA Technical Reports Server (NTRS)

    Bujold, M. P.

    1980-01-01

    A 1978 Chevrolet LUV manual transmission tested per the applicable portions of a passenger car automatic transmission test code (SAE J65lb) which required drive performance, coast performance, and no load test conditions. Under these test conditions, the transmission attained maximum efficiencies in the upper ninety percent range for both drive performance tests and coast performance tests. The major results of this test (torque, speed, and efficiency curves) are presented. Graphs map the complete performance characteristics for the Chevrolet LUV transmission.

  4. Small passenger car transmission test; Ford C4 transmission

    NASA Technical Reports Server (NTRS)

    Bujold, M. P.

    1980-01-01

    A 1979 Ford C4 automatic transmission was tested per a passenger car automatic transmission test code (SAE J651b) which required drive performance, coast performance, and no load test conditions. Under these test conditions, the transmission attained maximum efficiencies in the mid-eighty percent range for both drive performance tests and coast performance tests. The major results of this test (torque, speed, and efficiency curves) are presented. Graphs map the complete performance characteristics for the Ford C4 transmission.

  5. Functional Performance Testing for Power and Return to Sports

    PubMed Central

    Manske, Robert; Reiman, Michael

    2013-01-01

    Context: Functional performance testing of athletes can determine physical limitations that may affect sporting activities. Optimal functional performance testing simulates the athlete’s activity. Evidence Acquisition: A Medline search from 1960 to 2012 was implemented with the keywords functional testing, functional impairment testing, and functional performance testing in the English language. Each author also undertook independent searches of article references. Conclusion: Functional performance tests can bridge the gap between general physical tests and full, unrestricted athletic activity. PMID:24427396

  6. Performance testing accountability measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oldham, R.D.; Mitchell, W.G.; Spaletto, M.I.

    The New Brunswick Laboratory (NBL) provides assessment support to the DOE Operations Offices in the area of Material Control and Accountability (MC and A). During surveys of facilities, the Operations Offices have begun to request from NBL either assistance in providing materials for performance testing of accountability measurements or both materials and personnel to do performance testing. To meet these needs, NBL has developed measurement and measurement control performance test procedures and materials. The present NBL repertoire of performance tests include the following: (1) mass measurement performance testing procedures using calibrated and traceable test weights, (2) uranium elemental concentration (assay)more » measurement performance tests which use ampulated solutions of normal uranyl nitrate containing approximately 7 milligrams of uranium per gram of solution, and (3) uranium isotopic measurement performance tests which use ampulated uranyl nitrate solutions with enrichments ranging from 4% to 90% U-235. The preparation, characterization, and packaging of the uranium isotopic and assay performance test materials were done in cooperation with the NBL Safeguards Measurements Evaluation Program since these materials can be used for both purposes.« less

  7. Performance testing of EVs in the EPRI/TVA EV program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Driggans, R.L.

    1983-01-01

    Performance testing has been completed on four electric vehicles: the Grumman-Olson Kubvan, SCT Electric (VW) Pickup, Jet Industries Electrica, and VW Electrotransporter Bus. The tests performed included vehicle dc energy consumption and driving range at constant speeds and on the SAE J227a C cycle, on-road driving range, hill climbing, maximum acceleration, top speed, and braking performance. Descriptions of the vehicles tested and comparisons of major performance parameters on all four vehicles are presented. This testing was performed at the TVA Electric Vehicle Test Facility.

  8. Improving Test-Taking Performance of Secondary At-Risk Youth and Students with Disabilities

    ERIC Educational Resources Information Center

    Banks, Tachelle; Eaton, India

    2014-01-01

    Preparing at-risk youth and students with mild disabilities for state and district tests is important for improving their test performance, and basic instruction in test preparation can significantly improve student test performance. The article defines noncognitive variables that adversely affect test-taker performance. The article also describes…

  9. Small passenger car transmission test: Mercury Lynx ATX transmission

    NASA Technical Reports Server (NTRS)

    Bujold, M. P.

    1981-01-01

    The testing of a Mercury Lynx automatic transmission is reported. The transmission was tested in accordance with a passenger car automatic transmission test code (SAE J65lb) which required drive performance, coast performance, and no load test conditions. Under these conditions, the transmission attained maximum efficiencies in the mid-ninety percent range both for drive performance test and coast performance tests. The torque, speed, and efficiency curves are presented, which provide the complete performance characteristics for the Mercury Lynx automatic transmission.

  10. Power Performance Test Report for the Viryd CS8 Wind Turbine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roadman, J.; Murphy, M.; van Dam, J.

    2012-12-01

    This report contains the results of the power performance test that was performed on a Viryd CS8 wind turbine as part of the DOE Independent Testing project. The test is an accredited test to the IEC 61400-12-1 power performance standard.

  11. Small passenger car transmission test-Chevrolet 200 transmission

    NASA Technical Reports Server (NTRS)

    Bujold, M. P.

    1980-01-01

    The small passenger car transmission was tested to supply electric vehicle manufacturers with technical information regarding the performance of commerically available transmissions which would enable them to design a more energy efficient vehicle. With this information the manufacturers could estimate vehicle driving range as well as speed and torque requirements for specific road load performance characteristics. A 1979 Chevrolet Model 200 automatic transmission was tested per a passenger car automatic transmission test code (SAE J651b) which required drive performance, coast performance, and no load test conditions. The transmission attained maximum efficiencies in the mid-eighty percent range for both drive performance tests and coast performance tests. Torque, speed and efficiency curves map the complete performance characteristics for Chevrolet Model 200 transmission.

  12. Development of a standardized battery of performance tests for the assessment of noise stress effects

    NASA Technical Reports Server (NTRS)

    Theologus, G. C.; Wheaton, G. R.; Mirabella, A.; Brahlek, R. E.

    1973-01-01

    A set of 36 relatively independent categories of human performance were identified. These categories encompass human performance in the cognitive, perceptual, and psychomotor areas, and include diagnostic measures and sensitive performance metrics. Then a prototype standardized test battery was constructed, and research was conducted to obtain information on the sensitivity of the tests to stress, the sensitivity of selected categories of performance degradation, the time course of stress effects on each of the selected tests, and the learning curves associated with each test. A research project utilizing a three factor partially repeated analysis of covariance design was conducted in which 60 male subjects were exposed to variations in noise level and quality during performance testing. Effects of randomly intermittent noise on performance of the reaction time tests were observed, but most of the other performance tests showed consistent stability. The results of 14 analyses of covariance of the data taken from the performance of the 60 subjects on the prototype standardized test battery provided information which will enable the final development and test of a standardized test battery and the associated development of differential sensitivity metrics and diagnostic classificatory system.

  13. 40 CFR 63.7515 - When must I conduct subsequent performance tests, fuel analyses, or tune-ups?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... performance tests, fuel analyses, or tune-ups? 63.7515 Section 63.7515 Protection of Environment ENVIRONMENTAL..., fuel analyses, or tune-ups? (a) You must conduct all applicable performance tests according to § 63... performance tests and the associated fuel analyses within 60 days after the completion of the performance...

  14. 40 CFR 63.7515 - When must I conduct subsequent performance tests, fuel analyses, or tune-ups?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... performance tests, fuel analyses, or tune-ups? 63.7515 Section 63.7515 Protection of Environment ENVIRONMENTAL..., fuel analyses, or tune-ups? (a) You must conduct all applicable performance tests according to § 63... performance tests and the associated fuel analyses within 60 days after the completion of the performance...

  15. 49 CFR Appendix A to Part 665 - Tests To Be Performed at the Bus Testing Facility

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 7 2014-10-01 2014-10-01 false Tests To Be Performed at the Bus Testing Facility... Part 665—Tests To Be Performed at the Bus Testing Facility The eight tests to be performed on each vehicle are required by SAFETEA-LU and are based in part on tests described in the FTA report “First...

  16. 49 CFR Appendix A to Part 665 - Tests To Be Performed at the Bus Testing Facility

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Tests To Be Performed at the Bus Testing Facility... Part 665—Tests To Be Performed at the Bus Testing Facility The eight tests to be performed on each vehicle are required by SAFETEA-LU and are based in part on tests described in the FTA report “First...

  17. Stereotype Threat, Test Anxiety, and Mathematics Performance

    ERIC Educational Resources Information Center

    Tempel, Tobias; Neumann, Roland

    2014-01-01

    We investigated the combined effects of stereotype threat and trait test anxiety on mathematics test performance. Stereotype threat and test anxiety interacted with each other in affecting performance. Trait test anxiety predicted performance only in a diagnostic condition that prevented stereotype threat by stereotype denial. A state measure of…

  18. 40 CFR 63.1546 - Performance testing.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 13 2012-07-01 2012-07-01 false Performance testing. 63.1546 Section... Emission Standards for Hazardous Air Pollutants for Primary Lead Smelting § 63.1546 Performance testing. (a... performance test shall consist of at least three runs. For each test run with Method 12 or Method 29, the...

  19. Performance Testing of a Trace Contaminant Control Subassembly for the International Space Station

    NASA Technical Reports Server (NTRS)

    Perry, J. L.; Curtis, R. E.; Alexandre, K. L.; Ruggiero, L. L.; Shtessel, N.

    1998-01-01

    As part of the International Space Station (ISS) Trace Contaminant Control Subassembly (TCCS) development, a performance test has been conducted to provide reference data for flight verification analyses. This test, which used the U.S. Habitation Module (U.S. Hab) TCCS as the test article, was designed to add to the existing database on TCCS performance. Included in this database are results obtained during ISS development testing; testing of functionally similar TCCS prototype units; and bench scale testing of activated charcoal, oxidation catalyst, and granular lithium hydroxide (LiOH). The present database has served as the basis for the development and validation of a computerized TCCS process simulation model. This model serves as the primary means for verifying the ISS TCCS performance. In order to mitigate risk associated with this verification approach, the U.S. Hab TCCS performance test provides an additional set of data which serve to anchor both the process model and previously-obtained development test data to flight hardware performance. The following discussion provides relevant background followed by a summary of the test hardware, objectives, requirements, and facilities. Facility and test article performance during the test is summarized, test results are presented, and the TCCS's performance relative to past test experience is discussed. Performance predictions made with the TCCS process model are compared with the U.S. Hab TCCS test results to demonstrate its validation.

  20. 40 CFR 60.2922 - How do I conduct the initial and annual performance test?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... of this part must be used. (ii) The post-test moisture removal procedure described in section 8.1.6... performance test? 60.2922 Section 60.2922 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Testing § 60.2922 How do I conduct the initial and annual performance test? (a) All performance tests must...

  1. 40 CFR 60.2922 - How do I conduct the initial and annual performance test?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... of this part must be used. (ii) The post-test moisture removal procedure described in section 8.1.6... performance test? 60.2922 Section 60.2922 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Testing § 60.2922 How do I conduct the initial and annual performance test? (a) All performance tests must...

  2. 10 CFR 707.11 - Drugs for which testing is performed.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 4 2014-01-01 2014-01-01 false Drugs for which testing is performed. 707.11 Section 707... Drugs for which testing is performed. Where testing is performed under this part, at a minimum... occurrence testing, the contractor may test for any drug listed in Schedules I or II of the Controlled...

  3. 10 CFR 707.11 - Drugs for which testing is performed.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 4 2013-01-01 2013-01-01 false Drugs for which testing is performed. 707.11 Section 707... Drugs for which testing is performed. Where testing is performed under this part, at a minimum... occurrence testing, the contractor may test for any drug listed in Schedules I or II of the Controlled...

  4. 10 CFR 707.11 - Drugs for which testing is performed.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Drugs for which testing is performed. 707.11 Section 707... Drugs for which testing is performed. Where testing is performed under this part, at a minimum... occurrence testing, the contractor may test for any drug listed in Schedules I or II of the Controlled...

  5. 10 CFR 707.11 - Drugs for which testing is performed.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 4 2012-01-01 2012-01-01 false Drugs for which testing is performed. 707.11 Section 707... Drugs for which testing is performed. Where testing is performed under this part, at a minimum... occurrence testing, the contractor may test for any drug listed in Schedules I or II of the Controlled...

  6. 10 CFR 707.11 - Drugs for which testing is performed.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Drugs for which testing is performed. 707.11 Section 707... Drugs for which testing is performed. Where testing is performed under this part, at a minimum... occurrence testing, the contractor may test for any drug listed in Schedules I or II of the Controlled...

  7. 40 CFR 60.723 - Performance tests and compliance provisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Industrial Surface Coating: Surface Coating of Plastic Parts for Business Machines § 60.723 Performance tests... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Performance tests and compliance...

  8. 40 CFR 60.723 - Performance tests and compliance provisions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Industrial Surface Coating: Surface Coating of Plastic Parts for Business Machines § 60.723 Performance tests... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Performance tests and compliance...

  9. Fluid infusion system

    NASA Technical Reports Server (NTRS)

    1974-01-01

    Performance testing carried out in the development of the prototype zero-g fluid infusion system is described and summarized. Engineering tests were performed in the course of development, both on the original breadboard device and on the prototype system. This testing was aimed at establishing baseline system performance parameters and facilitating improvements. Acceptance testing was then performed on the prototype system to verify functional performance. Acceptance testing included a demonstration of the fluid infusion system on a laboratory animal.

  10. 40 CFR 63.1546 - Performance testing.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 13 2013-07-01 2012-07-01 true Performance testing. 63.1546 Section 63... Emission Standards for Hazardous Air Pollutants for Primary Lead Smelting § 63.1546 Performance testing. (a... performance test shall consist of at least three runs. For each test run with Method 12 or Method 29, the...

  11. Chinese College Test Takers' Individual Differences and Reading Test Performance: A Structural Equation Modeling Approach.

    PubMed

    Zhang, Limei

    2016-06-01

    This study reports on the relationships between test takers' individual differences and their performance on a reading comprehension test. A total of 518 Chinese college students (252 women and 256 men; M age = 19.26 year, SD = 0.98) answered a questionnaire and sit for a reading comprehension test. The study found that test takers' L2 language proficiency was closely linked to their test performance. Test takers' employment of strategies was significantly and positively associated with their performance on the test. Test takers' motivation was found to be significantly associated with reading test performance. Test anxiety was negatively related to their use of reading strategies and test performance. The results of the study lent support to the threshold hypothesis of language proficiency. The implications for classroom teaching were provided. © The Author(s) 2016.

  12. Transit car demonstration test program on the roll dynamics unit. Volume 2. Demonstration of a transit car performance test on the roll dynamic unit. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arnold, G.; Nelson, S.; Cooperrider, N.K.

    1982-02-11

    This report, Volume II, contains the results, conclusions, and recommendations of the first performance test of a transit care on the RDU. This report is limited to performance tests. The objective is to identify advantages and disadvantages of performance testing on the rollers of the RDU as highlighted by the SOAC test. The report involved separate testing, done by TTC personnel, in such traditional performance areas of transit vehicle operation ass traction, acceleration/deceleration, energy consumption, and spin/slide performance. The results of the successful performance test of a transit car on a roller unit is presented and the advantages of thismore » method of testing is discussed. Acceleration, deceleration, spin/slide, and power consumption tests, although of limited scope in comparison to the track tests performed on the same transit car, did show the feasibility of roller testing. It is concluded that the RDU is most suited for developmental testing of transit car systems particularly for power consumption and for cars with non-standard wheel gage. Tests should be of such scope as to justify the cost of car setup on the RDU. The following two test are recommended: (1) a power consumption study for a standard/non-standard gage transit car which investigates methods of reducing power consumption and (2) a non-standard gage full performance test.« less

  13. 47 CFR 76.601 - Performance tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 4 2011-10-01 2011-10-01 false Performance tests. 76.601 Section 76.601... CABLE TELEVISION SERVICE Technical Standards § 76.601 Performance tests. (a) The operator of each cable... cable television system shall conduct complete performance tests of that system at least twice each...

  14. 47 CFR 76.601 - Performance tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 4 2012-10-01 2012-10-01 false Performance tests. 76.601 Section 76.601... CABLE TELEVISION SERVICE Technical Standards § 76.601 Performance tests. (a) The operator of each cable... cable television system shall conduct complete performance tests of that system at least twice each...

  15. 47 CFR 76.601 - Performance tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 4 2014-10-01 2014-10-01 false Performance tests. 76.601 Section 76.601... CABLE TELEVISION SERVICE Technical Standards § 76.601 Performance tests. (a) The operator of each cable... cable television system shall conduct complete performance tests of that system at least twice each...

  16. 40 CFR 60.3027 - How do I conduct the initial and annual performance test?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 26A of appendix A of this part must be used. (ii) The post-test moisture removal procedure described... performance test? 60.3027 Section 60.3027 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED..., 2004 Model Rule-Performance Testing § 60.3027 How do I conduct the initial and annual performance test...

  17. 40 CFR 60.2922 - How do I conduct the initial and annual performance test?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 26A of appendix A of this part must be used. (ii) The post-test moisture removal procedure described... performance test? 60.2922 Section 60.2922 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Qualification Performance Testing § 60.2922 How do I conduct the initial and annual performance test? (a) All...

  18. 40 CFR 60.3027 - How do I conduct the initial and annual performance test?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 26A of appendix A of this part must be used. (ii) The post-test moisture removal procedure described... performance test? 60.3027 Section 60.3027 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED..., 2004 Model Rule-Performance Testing § 60.3027 How do I conduct the initial and annual performance test...

  19. 40 CFR 60.3027 - How do I conduct the initial and annual performance test?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 26A of appendix A of this part must be used. (ii) The post-test moisture removal procedure described... performance test? 60.3027 Section 60.3027 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED..., 2004 Model Rule-Performance Testing § 60.3027 How do I conduct the initial and annual performance test...

  20. 40 CFR 60.3027 - How do I conduct the initial and annual performance test?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 26A of appendix A of this part must be used. (ii) The post-test moisture removal procedure described... performance test? 60.3027 Section 60.3027 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED..., 2004 Model Rule-Performance Testing § 60.3027 How do I conduct the initial and annual performance test...

  1. 40 CFR 60.3027 - How do I conduct the initial and annual performance test?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 26A of appendix A of this part must be used. (ii) The post-test moisture removal procedure described... performance test? 60.3027 Section 60.3027 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED..., 2004 Model Rule-Performance Testing § 60.3027 How do I conduct the initial and annual performance test...

  2. 40 CFR 60.2922 - How do I conduct the initial and annual performance test?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 26A of appendix A of this part must be used. (ii) The post-test moisture removal procedure described... performance test? 60.2922 Section 60.2922 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Qualification Performance Testing § 60.2922 How do I conduct the initial and annual performance test? (a) All...

  3. 40 CFR 60.2922 - How do I conduct the initial and annual performance test?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 26A of appendix A of this part must be used. (ii) The post-test moisture removal procedure described... performance test? 60.2922 Section 60.2922 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Qualification Performance Testing § 60.2922 How do I conduct the initial and annual performance test? (a) All...

  4. Manufacture and evaluation of Li/BCX DD cells

    NASA Technical Reports Server (NTRS)

    Meyer, S.; Takeuchi, E.

    1990-01-01

    This project is divided into four main tasks: cell manufacture, acceptance, and lot certification of cells, performance testing of cells, and abuse testing of cells. Lithium/bromine chloride in thionyl chloride (Li/BCX) 149 DD cells (PN 3B2085-XA) were built according to the provisions of Electrochem Industries Quality Plan 17096. Acceptance and lot certification testing was performed according to NASA JSC Document EP5-83-025, Revision B. Acceptance testing included open circuit and load voltage check, visual examination, size and weight measurements, and high temperature exposure. Lot certification tests were performed for capacity performance and for performance under conditions of thermal and electrical abuse. These tests included 149 C exposure, capacity discharge, fuse check, high temperature exposure, high rate discharge, short circuit, vibration, and overdischarge testing. A quantity of 200 cells was delivered to Johnson Space Center for life test evaluation. A parametric evaluation of the capacity discharge of Li/BCX DD cells was performed over a variety of temperatures and discharge rates. This testing served to map the performance capability of the cell. Tests were also performed over a variety of electrical and thermal abuse conditions. Abuse tests included short circuit, charging, overdischarge, high temperature exposure, shock, and vibration.

  5. Identifying failure in a tree network of a parallel computer

    DOEpatents

    Archer, Charles J.; Pinnow, Kurt W.; Wallenfelt, Brian P.

    2010-08-24

    Methods, parallel computers, and products are provided for identifying failure in a tree network of a parallel computer. The parallel computer includes one or more processing sets including an I/O node and a plurality of compute nodes. For each processing set embodiments include selecting a set of test compute nodes, the test compute nodes being a subset of the compute nodes of the processing set; measuring the performance of the I/O node of the processing set; measuring the performance of the selected set of test compute nodes; calculating a current test value in dependence upon the measured performance of the I/O node of the processing set, the measured performance of the set of test compute nodes, and a predetermined value for I/O node performance; and comparing the current test value with a predetermined tree performance threshold. If the current test value is below the predetermined tree performance threshold, embodiments include selecting another set of test compute nodes. If the current test value is not below the predetermined tree performance threshold, embodiments include selecting from the test compute nodes one or more potential problem nodes and testing individually potential problem nodes and links to potential problem nodes.

  6. Test Takers' Performance Appraisals, Appraisal Calibration, and Cognitive and Metacognitive Strategy Use

    ERIC Educational Resources Information Center

    Phakiti, Aek

    2016-01-01

    The current study explores the nature and relationships among test takers' performance appraisals, appraisal calibration, and reported cognitive and metacognitive strategy use in a language test situation. Performance appraisals are executive processes of strategic competence for judging test performance (e.g., evaluating the correctness or…

  7. Durability of hardboard siding

    Treesearch

    Anton TenWolde; Charles Carll

    2004-01-01

    In response to concerns about hardboard siding failures, a study was performed to assess if performance in a current hardboard industry quality assurance test procedure correlated with in-service performance and how well this performance might be predicted by use of alternative or additional test procedures. A variety of laboratory tests were performed on a large...

  8. Physical Performance in Elite Male and Female Team Handball Players.

    PubMed

    Wagner, Herbert; Fuchs, Patrick; Fusco, Andrea; Fuchs, Philip; Bell, W Jeffrey; Duvillard, Serge P

    2018-06-12

    Biological differences between men and women are well known; however, literature-addressing knowledge about the influence of sex to specific and general performance in team handball is almost nonexistent. Consequently, the aim of the study was to assess and compare specific and general physical performance in male and female elite team handball players, to determine if the differences are consequential for general compared to specific physical performance characteristics and the relationship between general and specific physical performance. Twelve male and ten female elite team handball players performed a game based performance test, upper- und lower-body strength and power tests, a sprinting test, and an incremental treadmill-running test. Significant differences (P<.05) between male and female players were found for peak oxygen uptake and total running time during the treadmill test, 30m sprinting time, leg extension strength, trunk and shoulder rotation torque, counter movement jump height as well as offense and defense time, ball velocity and jump height in the game based performance test. An interaction (sex × test) was found for time and oxygen uptake and except shoulder rotation torque and ball velocity in females, we found only a low relationship between specific and general physical performance. The results of the study revealed that male players are heavier, taller, faster, stronger, jump higher and have a better aerobic performance. However, female players performed relatively better in the team handball specific tests compared to the general tests. Our findings also suggest that female players should focus more on strength training.

  9. Perceptual-cognitive skill and the in situ performance of soccer players.

    PubMed

    van Maarseveen, Mariëtte J J; Oudejans, Raôul R D; Mann, David L; Savelsbergh, Geert J P

    2018-02-01

    Many studies have shown that experts possess better perceptual-cognitive skills than novices (e.g., in anticipation, decision making, pattern recall), but it remains unclear whether a relationship exists between performance on those tests of perceptual-cognitive skill and actual on-field performance. In this study, we assessed the in situ performance of skilled soccer players and related the outcomes to measures of anticipation, decision making, and pattern recall. In addition, we examined gaze behaviour when performing the perceptual-cognitive tests to better understand whether the underlying processes were related when those perceptual-cognitive tasks were performed. The results revealed that on-field performance could not be predicted on the basis of performance on the perceptual-cognitive tests. Moreover, there were no strong correlations between the level of performance on the different tests. The analysis of gaze behaviour revealed differences in search rate, fixation duration, fixation order, gaze entropy, and percentage viewing time when performing the test of pattern recall, suggesting that it is driven by different processes to those used for anticipation and decision making. Altogether, the results suggest that the perceptual-cognitive tests may not be as strong determinants of actual performance as may have previously been assumed.

  10. Application of Athletic Movement Tests that Predict Injury Risk in a Military Population: Development of Normative Data.

    PubMed

    Teyhen, Deydre S; Shaffer, Scott W; Butler, Robert J; Goffar, Stephen L; Kiesel, Kyle B; Rhon, Daniel I; Boyles, Robert E; McMillian, Daniel J; Williamson, Jared N; Plisky, Phillip J

    2016-10-01

    Performance on movement tests helps to predict injury risk in a variety of physically active populations. Understanding baseline measures for normal is an important first step. Determine differences in physical performance assessments and describe normative values for these tests based on military unit type. Assessment of power, balance, mobility, motor control, and performance on the Army Physical Fitness Test were assessed in a cohort of 1,466 soldiers. Analysis of variance was performed to compare the results based on military unit type (Rangers, Combat, Combat Service, and Combat Service Support) and analysis of covariance was performed to determine the influence of age and gender. Rangers performed the best on all performance and fitness measures (p < 0.05). Combat soldiers performed better than Combat Service and Service Support soldiers on several physical performance tests and the Army Physical Fitness Test (p < 0.05). Performance in Combat Service and Service Support soldiers was equivalent on most measures (p < 0.05). Functional performance and level of fitness varied significantly by military unit type. Understanding these differences will provide a foundation for future injury prediction and prevention strategies. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.

  11. Evaluation of Asphalt Mixture Low-Temperature Performance in Bending Beam Creep Test.

    PubMed

    Pszczola, Marek; Jaczewski, Mariusz; Rys, Dawid; Jaskula, Piotr; Szydlowski, Cezary

    2018-01-10

    Low-temperature cracking is one of the most common road pavement distress types in Poland. While bitumen performance can be evaluated in detail using bending beam rheometer (BBR) or dynamic shear rheometer (DSR) tests, none of the normalized test methods gives a comprehensive representation of low-temperature performance of the asphalt mixtures. This article presents the Bending Beam Creep test performed at temperatures from -20 °C to +10 °C in order to evaluate the low-temperature performance of asphalt mixtures. Both validation of the method and its utilization for the assessment of eight types of wearing courses commonly used in Poland were described. The performed test indicated that the source of bitumen and its production process (and not necessarily only bitumen penetration) had a significant impact on the low-temperature performance of the asphalt mixtures, comparable to the impact of binder modification (neat, polymer-modified, highly modified) and the aggregate skeleton used in the mixture (Stone Mastic Asphalt (SMA) vs. Asphalt Concrete (AC)). Obtained Bending Beam Creep test results were compared with the BBR bitumen test. Regression analysis confirmed that performing solely bitumen tests is insufficient for comprehensive low-temperature performance analysis.

  12. Evaluation of Asphalt Mixture Low-Temperature Performance in Bending Beam Creep Test

    PubMed Central

    Rys, Dawid; Jaskula, Piotr; Szydlowski, Cezary

    2018-01-01

    Low-temperature cracking is one of the most common road pavement distress types in Poland. While bitumen performance can be evaluated in detail using bending beam rheometer (BBR) or dynamic shear rheometer (DSR) tests, none of the normalized test methods gives a comprehensive representation of low-temperature performance of the asphalt mixtures. This article presents the Bending Beam Creep test performed at temperatures from −20 °C to +10 °C in order to evaluate the low-temperature performance of asphalt mixtures. Both validation of the method and its utilization for the assessment of eight types of wearing courses commonly used in Poland were described. The performed test indicated that the source of bitumen and its production process (and not necessarily only bitumen penetration) had a significant impact on the low-temperature performance of the asphalt mixtures, comparable to the impact of binder modification (neat, polymer-modified, highly modified) and the aggregate skeleton used in the mixture (Stone Mastic Asphalt (SMA) vs. Asphalt Concrete (AC)). Obtained Bending Beam Creep test results were compared with the BBR bitumen test. Regression analysis confirmed that performing solely bitumen tests is insufficient for comprehensive low-temperature performance analysis. PMID:29320443

  13. Factors Contributing to Single- and Dual-Task Timed "Up & Go" Test Performance in Middle-Aged and Older Adults Who Are Active and Dwell in the Community.

    PubMed

    Chen, Hui-Ya; Tang, Pei-Fang

    2016-03-01

    Dual-task Timed "Up & Go" (TUG) tests are likely to have applications different from those of a single-task TUG test and may have different contributing factors. The purpose of this study was to compare factors contributing to performance on single- and dual-task TUG tests. This investigation was a cross-sectional study. Sixty-four adults who were more than 50 years of age and dwelled in the community were recruited. Interviews and physical examinations were performed to identify potential contributors to TUG test performance. The time to complete the single-task TUG test (TUGsingle) or the dual-task TUG test, which consisted of completing the TUG test while performing a serial subtraction task (TUGcognitive) or while carrying water (TUGmanual), was measured. Age, hip extensor strength, walking speed, general mental function, and Stroop scores for word and color were significantly associated with performance on all TUG tests. Hierarchical multiple regression models, without the input of walking speed, revealed different independent factors contributing to TUGsingle performance (Mini-Mental Status Examination score, β=-0.32), TUGmanual performance (age, β=0.35), and TUGcognitive performance (Stroop word score, β=-0.40; Mini-Mental Status Examination score, β=-0.31). At least 40% of the variance in the performance on the 3 TUG tests was not explained by common clinical measures, even when the factor of walking speed was considered. However, this study successfully identified some important factors contributing to performance on different TUG tests, and other studies have reported similar findings for single-task TUG test and dual-task gait performance. Although the TUGsingle and the TUGcognitive shared general mental function as a common factor, the TUGmanual was uniquely influenced by age and the TUGcognitive was uniquely influenced by focused attention. These results suggest that both common and unique factors contribute to performance on single- and dual-task TUG tests and suggest important applications of the combined use of the 3 TUG tests. © 2016 American Physical Therapy Association.

  14. High School Students' Performance on Vandenberg's Mental Rotations Test: Art Ability, Gender, Activities, Academic Performance, Strategies, and Ease of Taking the Test.

    ERIC Educational Resources Information Center

    Gurny, Helen Graham

    This study tested whether mental rotation performance of 186 high school students (80 males and 106 females) in grades 9 through 12 in art and nonart classes on Vandenbergs Mental Rotations test (S. Vandenberg and Kuse, 1978) was affected by gender, visual-spatial activities, strategies used while performing the test, and the ease of test taking.…

  15. Functional Performance and Associations between Performance Tests and Neurological Assessment Differ in Men and Women with Parkinson's Disease.

    PubMed

    Medijainen, Kadri; Pääsuke, Mati; Lukmann, Aet; Taba, Pille

    2015-01-01

    Neurological assessment of a patient with Parkinson's disease (PD) is expected to reflect upon functional performance. As women are known to report more limitations even for same observed functional performance level, present study was designed to examine whether associations between neurological assessments and functional performance differ across genders. 14 men and 14 women with PD participated. Functional performance was assessed by measuring walking speeds on 10-meter walk test (10MWT) and by performing timed-up-and-go-test (TUG). Neurological assessment included Hoehn and Yahr Scale (HY), Movement Disorders Society Unified Parkinson's Disease Rating Scale (MDS-UPDRS), Schwab and England Activities of Daily Living Scale (S-E), and Mini Mental State Examination (MMSE). In women with PD, Kendall's tau-b correlation analyses revealed significant correlations between functional performance tests and neurological assessment measures, with the exception in MMSE. No corresponding associations were found for men, although they demonstrated better functional performance, as expected. Men in similar clinical stage of the PD perform better on functional tests than women. Disease severity reflects upon functional performance differently in men and women with PD. Results indicate that when interpreting the assessment results of both functional performance and neurological assessment tests, the gender of the patient should be taken into consideration.

  16. System performance testing of the DSN radio science system, Mark 3-78

    NASA Technical Reports Server (NTRS)

    Berman, A. L.; Mehta, J. S.

    1978-01-01

    System performance tests are required to evaluate system performance following initial system implementation and subsequent modification, and to validate system performance prior to actual operational usage. Non-real-time end-to-end Radio Science system performance tests are described that are based on the comparison of open-loop radio science data to equivalent closed-loop radio metric data, as well as an abbreviated Radio Science real-time system performance test that validates critical Radio Science System elements at the Deep Space Station prior to actual operational usage.

  17. Validation of a short cognitive battery to screen for fitness-to-drive of people with multiple sclerosis.

    PubMed

    Akinwuntan, A E; Backus, D; Grayson, J; Devos, H

    2018-05-26

    Some symptoms of multiple sclerosis (MS) affect driving. In a recent study, performance on five cognitive tests predicted the on-road test performance of individuals with relapsing-remitting MS with 91% accuracy, 70% sensitivity and 97% specificity. However, the accuracy with which the battery will predict the driving performance of a different cohort that includes all types of MS is unknown. Participants (n = 118; 48 ± 9 years of age; 97 females) performed a comprehensive off-road evaluation that lasted about 3 h and a standardized on-road test that lasted approximately 45 min over a 2-day period within the same week. Performance on the five cognitive tests was used to predict participants' performance on the standardized on-road test. Performance on the five tests together predicted outcome of the on-road test with 82% accuracy, 42% sensitivity and 90% specificity. The accuracy of predicting the on-road performance of a new MS cohort using performance on the battery of five cognitive tests remained very high (82%). The battery, which was administrable in <45 min and cost ~$150, was better at identifying those who actually passed the on-road test (90% specificity). The sensitivity (42%) of the battery indicated that it should not be used as the sole determinant of poor driving-related cognitive skills. A fail performance on the battery should only imply that more comprehensive testing is warranted. © 2018 EAN.

  18. The Reliability and Validity of Protocols for the Assessment of Endurance Sports Performance: An Updated Review

    ERIC Educational Resources Information Center

    Stevens, Christopher John; Dascombe, Ben James

    2015-01-01

    Sports performance testing is one of the most common and important measures used in sport science. Performance testing protocols must have high reliability to ensure any changes are not due to measurement error or inter-individual differences. High validity is also important to ensure test performance reflects true performance. Time-trial…

  19. Implementation and performance test of cloud platform based on Hadoop

    NASA Astrophysics Data System (ADS)

    Xu, Jingxian; Guo, Jianhong; Ren, Chunlan

    2018-01-01

    Hadoop, as an open source project for the Apache foundation, is a distributed computing framework that deals with large amounts of data and has been widely used in the Internet industry. Therefore, it is meaningful to study the implementation of Hadoop platform and the performance of test platform. The purpose of this subject is to study the method of building Hadoop platform and to study the performance of test platform. This paper presents a method to implement Hadoop platform and a test platform performance method. Experimental results show that the proposed test performance method is effective and it can detect the performance of Hadoop platform.

  20. Performance evaluation of Space Shuttle SRB parachutes from air drop and scaled model wind tunnel tests. [Solid Rocket Booster recovery system

    NASA Technical Reports Server (NTRS)

    Moog, R. D.; Bacchus, D. L.; Utreja, L. R.

    1979-01-01

    The aerodynamic performance characteristics have been determined for the Space Shuttle Solid Rocket Booster drogue, main, and pilot parachutes. The performance evaluation on the 20-degree conical ribbon parachutes is based primarily on air drop tests of full scale prototype parachutes. In addition, parametric wind tunnel tests were performed and used in parachute configuration development and preliminary performance assessments. The wind tunnel test data are compared to the drop test results and both sets of data are used to determine the predicted performance of the Solid Rocket Booster flight parachutes. Data from other drop tests of large ribbon parachutes are also compared with the Solid Rocket Booster parachute performance characteristics. Parameters assessed include full open terminal drag coefficients, reefed drag area, opening characteristics, clustering effects, and forebody interference.

  1. The intra- and inter-rater reliability of five clinical muscle performance tests in patients with and without neck pain

    PubMed Central

    2013-01-01

    Background This study investigates the reliability of muscle performance tests using cost- and time-effective methods similar to those used in clinical practice. When conducting reliability studies, great effort goes into standardising test procedures to facilitate a stable outcome. Therefore, several test trials are often performed. However, when muscle performance tests are applied in the clinical setting, clinicians often only conduct a muscle performance test once as repeated testing may produce fatigue and pain, thus variation in test results. We aimed to investigate whether cervical muscle performance tests, which have shown promising psychometric properties, would remain reliable when examined under conditions similar to those of daily clinical practice. Methods The intra-rater (between-day) and inter-rater (within-day) reliability was assessed for five cervical muscle performance tests in patients with (n = 33) and without neck pain (n = 30). The five tests were joint position error, the cranio-cervical flexion test, the neck flexor muscle endurance test performed in supine and in a 45°-upright position and a new neck extensor test. Results Intra-rater reliability ranged from moderate to almost perfect agreement for joint position error (ICC ≥ 0.48-0.82), the cranio-cervical flexion test (ICC ≥ 0.69), the neck flexor muscle endurance test performed in supine (ICC ≥ 0.68) and in a 45°-upright position (ICC ≥ 0.41) with the exception of a new test (neck extensor test), which ranged from slight to moderate agreement (ICC = 0.14-0.41). Likewise, inter-rater reliability ranged from moderate to almost perfect agreement for joint position error (ICC ≥ 0.51-0.75), the cranio-cervical flexion test (ICC ≥ 0.85), the neck flexor muscle endurance test performed in supine (ICC ≥ 0.70) and in a 45°-upright position (ICC ≥ 0.56). However, only slight to fair agreement was found for the neck extensor test (ICC = 0.19-0.25). Conclusions Intra- and inter-rater reliability ranged from moderate to almost perfect agreement with the exception of a new test (neck extensor test), which ranged from slight to moderate agreement. The significant variability observed suggests that tests like the neck extensor test and the neck flexor muscle endurance test performed in a 45°-upright position are too unstable to be used when evaluating neck muscle performance. PMID:24299621

  2. 40 CFR 610.63 - Performance tests.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Performance tests. 610.63 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.63 Performance tests... 0 to 60 mph acceleration tests (at normal ambient temperatures) on the baseline vehicle...

  3. 40 CFR 610.63 - Performance tests.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Performance tests. 610.63 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.63 Performance tests... 0 to 60 mph acceleration tests (at normal ambient temperatures) on the baseline vehicle...

  4. 40 CFR 610.63 - Performance tests.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Performance tests. 610.63 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.63 Performance tests... 0 to 60 mph acceleration tests (at normal ambient temperatures) on the baseline vehicle...

  5. 40 CFR 610.63 - Performance tests.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Performance tests. 610.63 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Special Test Procedures § 610.63 Performance tests... 0 to 60 mph acceleration tests (at normal ambient temperatures) on the baseline vehicle...

  6. 40 CFR 63.7515 - When must I conduct subsequent performance tests or fuel analyses?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... performance tests or fuel analyses? 63.7515 Section 63.7515 Protection of Environment ENVIRONMENTAL PROTECTION... Requirements § 63.7515 When must I conduct subsequent performance tests or fuel analyses? (a) You must conduct... previous performance test. (f) You must conduct a fuel analysis according to § 63.7521 for each type of...

  7. 40 CFR 63.11220 - When must I conduct subsequent performance tests or fuel analyses?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... performance tests or fuel analyses? 63.11220 Section 63.11220 Protection of Environment ENVIRONMENTAL... When must I conduct subsequent performance tests or fuel analyses? (a) If your boiler has a heat input... performance (stack) tests according to § 63.11212 on a triennial basis, except as specified in paragraphs (b...

  8. 40 CFR 63.7515 - When must I conduct subsequent performance tests, fuel analyses, or tune-ups?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... performance tests, fuel analyses, or tune-ups? 63.7515 Section 63.7515 Protection of Environment ENVIRONMENTAL... Compliance Requirements § 63.7515 When must I conduct subsequent performance tests, fuel analyses, or tune... and the associated initial fuel analyses within 90 days after the completion of the performance tests...

  9. 40 CFR 63.7515 - When must I conduct subsequent performance tests or fuel analyses?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... performance tests or fuel analyses? 63.7515 Section 63.7515 Protection of Environment ENVIRONMENTAL PROTECTION... Requirements § 63.7515 When must I conduct subsequent performance tests or fuel analyses? (a) You must conduct... previous performance test. (f) You must conduct a fuel analysis according to § 63.7521 for each type of...

  10. 40 CFR 63.11220 - When must I conduct subsequent performance tests or fuel analyses?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... performance tests or fuel analyses? 63.11220 Section 63.11220 Protection of Environment ENVIRONMENTAL... When must I conduct subsequent performance tests or fuel analyses? (a) If your boiler has a heat input... performance (stack) tests according to § 63.11212 on a triennial basis, except as specified in paragraphs (b...

  11. 40 CFR 63.7515 - When must I conduct subsequent performance tests, fuel analyses, or tune-ups?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... performance tests, fuel analyses, or tune-ups? 63.7515 Section 63.7515 Protection of Environment ENVIRONMENTAL... Compliance Requirements § 63.7515 When must I conduct subsequent performance tests, fuel analyses, or tune... and the associated initial fuel analyses within 90 days after the completion of the performance tests...

  12. 40 CFR 63.7515 - When must I conduct subsequent performance tests or fuel analyses?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... performance tests or fuel analyses? 63.7515 Section 63.7515 Protection of Environment ENVIRONMENTAL PROTECTION... Requirements § 63.7515 When must I conduct subsequent performance tests or fuel analyses? (a) You must conduct... previous performance test. (f) You must conduct a fuel analysis according to § 63.7521 for each type of...

  13. 40 CFR 63.7187 - What performance tests and other compliance procedures must I use?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 13 2010-07-01 2010-07-01 false What performance tests and other... Manufacturing Compliance Requirements § 63.7187 What performance tests and other compliance procedures must I use? (a) You must conduct each performance test in Table 1 to this subpart that applies to you as...

  14. 40 CFR 63.1512 - Performance test/compliance demonstration requirements and procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... operator must conduct a performance test to measure THC and D/F emissions at the outlet of the control.../decoating kiln. The owner or operator must conduct performance tests to measure emissions of THC, D/F, HCl... operating temperature of each afterburner every 15 minutes during the THC and D/F performance tests; (ii...

  15. 40 CFR 63.1512 - Performance test/compliance demonstration requirements and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... operator must conduct a performance test to measure THC and D/F emissions at the outlet of the control.../decoating kiln. The owner or operator must conduct performance tests to measure emissions of THC, D/F, HCl... operating temperature of each afterburner every 15 minutes during the THC and D/F performance tests; (ii...

  16. 40 CFR 63.3960 - By what date must I conduct performance tests and other initial compliance demonstrations?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... performance test of one representative magnet wire coating machine for each group of identical or very similar... you complete the performance test of a representative magnet wire coating machine. The requirements in... operations, you may, with approval, conduct a performance test of a single magnet wire coating machine that...

  17. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Performance Verification Report: Initial Comprehensive Performance Test Report, P/N 1331200-2-IT, S/N 105/A2

    NASA Technical Reports Server (NTRS)

    Platt, R.

    1999-01-01

    This is the Performance Verification Report, Initial Comprehensive Performance Test Report, P/N 1331200-2-IT, S/N 105/A2, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A). The specification establishes the requirements for the Comprehensive Performance Test (CPT) and Limited Performance Test (LPT) of the Advanced Microwave Sounding, Unit-A2 (AMSU-A2), referred to herein as the unit. The unit is defined on Drawing 1331200. 1.2 Test procedure sequence. The sequence in which the several phases of this test procedure shall take place is shown in Figure 1, but the sequence can be in any order.

  18. Advanced Stirling Convertor (ASC-E2) Performance Testing at NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Oriti, Salvatore; Wilson, Scott

    2011-01-01

    The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has been supporting development of the Advanced Stirling Radioisotope Generator (ASRG) since 2006. A key element of the ASRG Project is providing life, reliability, and performance testing of the Advanced Stirling Convertor (ASC). For this purpose, four pairs of ASCs capable of operating to 850 C and designated with the model number ASC-E2, were delivered by Sunpower of Athens, OH, to GRC in 2010. The ASC-E2s underwent a series of tests that included workmanship vibration testing, performance mapping, and extended operation. Workmanship vibration testing was performed following fabrication of each convertor to verify proper hardware build. Performance mapping consisted of operating each convertor at various conditions representing the range expected during a mission. Included were conditions representing beginning-of-mission (BOM), end-of-mission (EOM), and fueling. This same series of tests was performed by Sunpower prior to ASC-E2 delivery. The data generated during the GRC test were compared to performance before delivery. Extended operation consisted of a 500-hour period of operation with conditions maintained at the BOM point. This was performed to demonstrate steady convertor performance following performance mapping. Following this initial 500-hour period, the ASC-E2s will continue extended operation, controller development and special durability testing, during which the goal is to accumulate tens of thousands of hours of operation. Data collected during extended operation will support reliability analysis. Performance data from these tests is summarized in this paper.

  19. Advanced Stirling Convertor (ASC-E2) Performance Testing at NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Oriti, Salvatore; Wilson, Scott

    2011-01-01

    The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has been supporting development of the Advanced Stirling Radioisotope Generator (ASRG) since 2006. A key element of the ASRG Project is providing life, reliability, and performance testing of the Advanced Stirling Convertor (ASC). For this purpose, four pairs of ASCs capable of operating to 850 C and designated with the model number ASC-E2, were delivered by Sunpower of Athens, Ohio, to GRC in 2010. The ASC-E2s underwent a series of tests that included workmanship vibration testing, performance mapping, and extended operation. Workmanship vibration testing was performed following fabrication of each convertor to verify proper hardware build. Performance mapping consisted of operating each convertor at various conditions representing the range expected during a mission. Included were conditions representing beginning-of-mission (BOM), end-of-mission (EOM), and fueling. This same series of tests was performed by Sunpower prior to ASC-E2 delivery. The data generated during the GRC test were compared to performance before delivery. Extended operation consisted of a 500-hr period of operation with conditions maintained at the BOM point. This was performed to demonstrate steady convertor performance following performance mapping. Following this initial 500-hr period, the ASC-E2s will continue extended operation, controller development and special durability testing, during which the goal is to accumulate tens of thousands of hours of operation. Data collected during extended operation will support reliability analysis. Performance data from these tests is summarized in this paper.

  20. Comparing the performance plateau in adult cochlear implant patients using HINT and AzBio.

    PubMed

    Massa, Sean T; Ruckenstein, Michael J

    2014-04-01

    This study aims to characterize the performance plateau in adult cochlear implant recipients after the initial postimplantation increase by using word recognition testing and an explicit definition of performance plateau. Retrospective review. Urban, tertiary referral center. One hundred twenty-five patients with 138 devices tested with AzBio were matched to 130 patients with 138 devices tested with HINT based on performed on CNC monosyllable tests. Patient's performance was measured overtime using AzBio and HINT tests to determine when and at what score their performance reached a plateau. Time from implantation to reach a performance plateau and plateau score with each test. Thirty-four devices reached a HINT plateau and 30 devices reached an AzBio plateau. Patients reached plateaus at similar times postoperatively using HINT and AzBio, 18.8 and 16.5 weeks, respectively (p = 0.476). Five patients tested with HINT plateaued at scores of 99% to 100%, whereas no patients plateaued above 92% with AzBio. Patients reached a plateau in performance at similar median times using AzBio and HINT, despite the ceiling effect of HINT in some patients. Most patients who reach a plateau did so within 4 months, but exactly when and if a patient's performance plateaus varies significantly among individuals. Further study is required to determine which test best reflects when a patient reaches his or her maximal performance in natural listening conditions.

  1. Preliminary supersonic flight test evaluation of performance seeking control

    NASA Technical Reports Server (NTRS)

    Orme, John S.; Gilyard, Glenn B.

    1993-01-01

    Digital flight and engine control, powerful onboard computers, and sophisticated controls techniques may improve aircraft performance by maximizing fuel efficiency, maximizing thrust, and extending engine life. An adaptive performance seeking control system for optimizing the quasi-steady state performance of an F-15 aircraft was developed and flight tested. This system has three optimization modes: minimum fuel, maximum thrust, and minimum fan turbine inlet temperature. Tests of the minimum fuel and fan turbine inlet temperature modes were performed at a constant thrust. Supersonic single-engine flight tests of the three modes were conducted using varied after burning power settings. At supersonic conditions, the performance seeking control law optimizes the integrated airframe, inlet, and engine. At subsonic conditions, only the engine is optimized. Supersonic flight tests showed improvements in thrust of 9 percent, increases in fuel savings of 8 percent, and reductions of up to 85 deg R in turbine temperatures for all three modes. The supersonic performance seeking control structure is described and preliminary results of supersonic performance seeking control tests are given. These findings have implications for improving performance of civilian and military aircraft.

  2. PrismTech Data Distribution Service Java API Evaluation

    NASA Technical Reports Server (NTRS)

    Riggs, Cortney

    2008-01-01

    My internship duties with Launch Control Systems required me to start performance testing of an Object Management Group's (OMG) Data Distribution Service (DDS) specification implementation by PrismTech Limited through the Java programming language application programming interface (API). DDS is a networking middleware for Real-Time Data Distribution. The performance testing involves latency, redundant publishers, extended duration, redundant failover, and read performance. Time constraints allowed only for a data throughput test. I have designed the testing applications to perform all performance tests when time is allowed. Performance evaluation data such as megabits per second and central processing unit (CPU) time consumption were not easily attainable through the Java programming language; they required new methods and classes created in the test applications. Evaluation of this product showed the rate that data can be sent across the network. Performance rates are better on Linux platforms than AIX and Sun platforms. Compared to previous C++ programming language API, the performance evaluation also shows the language differences for the implementation. The Java API of the DDS has a lower throughput performance than the C++ API.

  3. Gaia challenging performances verification: combination of spacecraft models and test results

    NASA Astrophysics Data System (ADS)

    Ecale, Eric; Faye, Frédéric; Chassat, François

    2016-08-01

    To achieve the ambitious scientific objectives of the Gaia mission, extremely stringent performance requirements have been given to the spacecraft contractor (Airbus Defence and Space). For a set of those key-performance requirements (e.g. end-of-mission parallax, maximum detectable magnitude, maximum sky density or attitude control system stability), this paper describes how they are engineered during the whole spacecraft development process, with a focus on the end-to-end performance verification. As far as possible, performances are usually verified by end-to-end tests onground (i.e. before launch). However, the challenging Gaia requirements are not verifiable by such a strategy, principally because no test facility exists to reproduce the expected flight conditions. The Gaia performance verification strategy is therefore based on a mix between analyses (based on spacecraft models) and tests (used to directly feed the models or to correlate them). Emphasis is placed on how to maximize the test contribution to performance verification while keeping the test feasible within an affordable effort. In particular, the paper highlights the contribution of the Gaia Payload Module Thermal Vacuum test to the performance verification before launch. Eventually, an overview of the in-flight payload calibration and in-flight performance verification is provided.

  4. 40 CFR 1066.430 - Performing emission tests.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Performing emission tests. 1066.430... CONTROLS VEHICLE-TESTING PROCEDURES Vehicle Preparation and Running a Test § 1066.430 Performing emission tests. The overall test consists of prescribed sequences of fueling, parking, and driving at specified...

  5. 40 CFR 1066.430 - Performing emission tests.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Performing emission tests. 1066.430... CONTROLS VEHICLE-TESTING PROCEDURES Vehicle Preparation and Running a Test § 1066.430 Performing emission tests. The overall test consists of prescribed sequences of fueling, parking, and driving at specified...

  6. A PILOT STUDY OF CORE STABILITY AND ATHLETIC PERFORMANCE: IS THERE A RELATIONSHIP?

    PubMed Central

    Sharrock, Chris; Cropper, Jarrod; Mostad, Joel; Johnson, Matt

    2011-01-01

    Study Design: Correlation study Objectives: To objectively evaluate the relationship between core stability and athletic performance measures in male and female collegiate athletes. Background: The relationship between core stability and athletic performance has yet to be quantified in the available literature. The current literature does not demonstrate whether or not core strength relates to functional performance. Questions remain regarding the most important components of core stability, the role of sport specificity, and the measurement of core stability in relation to athletic performance. Methods: A sample of 35 volunteer student athletes from Asbury College (NAIA Division II) provided informed consent. Participants performed a series of five tests: double leg lowering (core stability test), the forty yard dash, the T-test, vertical jump, and a medicine ball throw. Participants performed three trials of each test in a randomized order. Results: Correlations between the core stability test and each of the other four performance tests were determined using a General Linear Model. Medicine ball throw negatively correlated to the core stability test (r –0.389, p=0.023). Participants that performed better on the core stability test had a stronger negative correlation to the medicine ball throw (r =–0.527). Gender was the most strongly correlated variable to core strength, males with a mean measurement of double leg lowering of 47.43 degrees compared to females having a mean of 54.75 degrees. Conclusions: There appears to be a link between a core stability test and athletic performance tests; however, more research is needed to provide a definitive answer on the nature of this relationship. Ideally, specific performance tests will be able to better define and to examine relationships to core stability. Future studies should also seek to determine if there are specific sub-categories of core stability which are most important to allow for optimal training and performance for individual sports. PMID:21713228

  7. Application of the Athlete's Performance Passport for Doping Control: A Case Report.

    PubMed

    Iljukov, Sergei; Bermon, Stephane; Schumacher, Yorck O

    2018-01-01

    The efficient use of testing resources is a key issue in the fight against doping. The longitudinal tracking of sporting performances to identify unusual improvements possibly caused by doping, so-called "athlete's performance passport" (APP) is a new concept to improve targeted anti-doping testing. In fact, unusual performances by an athlete would trigger a more thorough testing program. In the present case report, performance data is modeled using the critical power concept for a group of athletes based on their past performances. By these means, an athlete with unusual deviations from his predicted performances was identified. Subsequent target testing using blood testing and the athlete biological passport resulted in an anti-doping rule violation procedure and suspension of the athlete. This case demonstrates the feasibility of the APP approach where athlete's performance is monitored and might serve as an example for the practical implementation of the method.

  8. Application of the Athlete's Performance Passport for Doping Control: A Case Report

    PubMed Central

    Iljukov, Sergei; Bermon, Stephane; Schumacher, Yorck O.

    2018-01-01

    The efficient use of testing resources is a key issue in the fight against doping. The longitudinal tracking of sporting performances to identify unusual improvements possibly caused by doping, so-called “athlete's performance passport” (APP) is a new concept to improve targeted anti-doping testing. In fact, unusual performances by an athlete would trigger a more thorough testing program. In the present case report, performance data is modeled using the critical power concept for a group of athletes based on their past performances. By these means, an athlete with unusual deviations from his predicted performances was identified. Subsequent target testing using blood testing and the athlete biological passport resulted in an anti-doping rule violation procedure and suspension of the athlete. This case demonstrates the feasibility of the APP approach where athlete's performance is monitored and might serve as an example for the practical implementation of the method. PMID:29651247

  9. J-2X Fuel Turbopump Point of Departure: The Performance of the J-2s Fuel Turbopump Inducer

    NASA Technical Reports Server (NTRS)

    Sargent, S. R.; Becht, D. G.; Mulder, A. D.

    2008-01-01

    To aid the J-2X program design effort with detailed performance and environment information, the J-2S fuel turbopump (FTP) inducer has undergone a thorough test series in both water and hydrogen. The test series utilizes both inducer only and a complete pump configuration to assess the inducer interaction to the overall turbopump system. The test goals include verification of suction performance against heritage J-2S data, head production, effects of thermodynamic suppression head (TSH), and evaluation of the inducer dynamic pressure caused by cavitation instabilities. Test facilities at both Pratt & Whitney Rocketdyne (PWR) and NASA s Stennis Space Center (SSC) are employed for the testing. The inducer only water test effort conducted at PWR established performance curves for suction performance, head production, and efficiency over a wide operating range. Because the heritage J-2S suction performance data set is in hydrogen, it is desired to obtain current suction performance data in hydrogen as well, thus avoiding the reliance on a theoretical TSH correlation for direct comparison. This data then provides an empirically based TSH correlation allowing for the comparison of water test suction data to system suction requirements. The FTP testing performed at SSC provides these suction performance relationships as well as inlet duct dynamic pressures during liquid hydrogen operation. The test effort successfully confirms the heritage J-2S suction performance and establishes the amount of TSH between water and hydrogen operation at the design flow coefficient. Correlating data is also obtained for cavitating instability frequency content, illustrating the validity of using the wide flow range water test data to predict hydrogen performance.

  10. Neuropsychological Test Performance in Cognitively Normal Spanish-speaking Nonagenarians with Little Education.

    PubMed

    Guerrero-Berroa, Elizabeth; Schmeidler, James; Raventos, Henriette; Valerio, Daniel; Beeri, Michal Schnaider; Carrión-Baralt, José R; Mora-Villalobos, Lara; Bolaños, Patricia; Sano, Mary; Silverman, Jeremy M

    2016-06-01

    To find associations of age, sex, and education with neuropsychological test performance in cognitively normal Spanish-speaking Costa Rican nonagenarians with little education; to provide norms; and to compare their performance with similar Puerto Ricans. For 95 Costa Ricans (90-102 years old, 0-6 years of education), multiple regression assessed associations with demographics of performance on six neuropsychological tests. Analyses of covariance compared them with 23 Puerto Ricans (90-99 years old). Younger age and being female-but not education-were associated with better performance on some neuropsychological tests, in particular episodic memory. The Puerto Ricans performed better on learning and memory tasks. In cognitively intact Spanish-speaking nonagenarians with little or no education, education did not affect test performance. Additional studies of the effect of education on cognitive performance are warranted in other samples with extremely low education or old age. National differences in performance highlight the importance of group-specific norms.

  11. Mild test anxiety influences neurocognitive performance among African Americans and European Americans: identifying interfering and facilitating sources.

    PubMed

    Thames, April D; Panos, Stella E; Arentoft, Alyssa; Byrd, Desiree A; Hinkin, Charles H; Arbid, Natalie

    2015-01-01

    The current study examined ethnic/racial differences in test-related anxiety and its relationship to neurocognitive performance in a community sample of African American (n = 40) and European American (n = 36) adults. The authors hypothesized the following: (a) Test-anxiety related to negative performance evaluation would be associated with lower neurocognitive performance, whereas anxiety unrelated to negative evaluation would be associated with higher neurocognitive performance. (b) African American participants would report higher levels of anxiety about negative performance evaluation than European Americans. (c) European Americans would report higher levels of anxiety unrelated to negative performance evaluation. The first two hypotheses were supported: Ethnic/racial differences in test-taking anxiety emerged such that African Americans reported significantly higher levels of negative performance evaluation, which was associated with lower cognitive performance. The third hypothesis was not supported: African Americans and European Americans reported similar levels of test-anxiety unrelated to negative evaluation. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  12. Neuropsychological Test Performance in Cognitively Normal Spanish-speaking Nonagenarians with Little Education

    PubMed Central

    Schmeidler, James; Raventos, Henriette; Valerio, Daniel; Beeri, Michal Schnaider; Carrión-Baralt, José R.; Mora-Villalobos, Lara; Bolaños, Patricia; Sano, Mary; Silverman, Jeremy M.

    2016-01-01

    To find associations of age, sex, and education with neuropsychological test performance in cognitively normal Spanish-speaking Costa Rican nonagenarians with little education; to provide norms; and to compare their performance with similar Puerto Ricans. For 95 Costa Ricans (90–102 years old, 0–6 years of education), multiple regression assessed associations with demographics of performance on six neuropsychological tests. Analyses of covariance compared them with 23 Puerto Ricans (90–99 years old). Younger age and being female—but not education—were associated with better performance on some neuropsychological tests, in particular episodic memory. The Puerto Ricans performed better on learning and memory tasks. In cognitively intact Spanish-speaking nonagenarians with little or no education, education did not affect test performance. Additional studies of the effect of education on cognitive performance are warranted in other samples with extremely low education or old age. National differences in performance highlight the importance of group-specific norms. PMID:26883764

  13. Performance tests.

    PubMed Central

    Wetherell, A

    1996-01-01

    This paper discusses the use of psychological performance tests to assess the effects of environmental stressors. The large number and the variety of performance tests are illustrated, and the differences between performance tests and other psychological tests are described in terms of their design, construction, use, and purpose. The stressor emphasis is on the effects of drugs since that is where most performance tests have found their main application, although other stressors, e.g., fatigue, toxic chemicals, are mentioned where appropriate. Diazepam is used as an example. There is no particular performance emphasis since the tests are intended to have wide applicability. However, vehicle-driving performance is discussed because it has been the subject of a great deal of research and is probably one of the most important areas of application. Performance tests are discussed in terms of the four main underlying models--factor analysis, general information processing, multiple resource and strategy models, and processing-stage models--and in terms of their psychometric properties--sensitivity, reliability, and content, criterion, construct, and face validity. Some test taxonomies are presented. Standardization is also discussed with reference to the reaction time, mathematical processing, memory search, spatial processing, unstable tracking, verbal processing, and dual task tests used in the AGARD STRES battery. Some comments on measurement strengths and appropriate study designs and methods are included. PMID:9182033

  14. Field tests of 2- and 40-tube condensers at the East Mesa Geothermal Test Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murphy, R.W.; Domingo, N.

    1982-05-01

    Two water-cooled isobutane condensers, one with 2 tubes and one with 40 tubes, were subjected to field tests at the East Mesa Geothermal Test Site to assess relative heat transfer performance in both surface evaporator and direct-contact evaporator modes. The five groups of tests established that field performance was below earlier laboratory-determined levels and that direct-contact evaporator mode performance was poorer than that for the surface evaporator mode. In all test situations, fluted condenser tubes performed better than smooth condenser tubes. Cooling water quality had no significant effect on performance, but brine preflash in the direct-contact mode did promote somemore » relative performance improvement. Important implications of these results for binary geothermal power plants are that (1) working-fluid-side impurities can significantly degrade heat transfer performance of the power plant condensers and (2) provisions for minimizing such impurities may be required.« less

  15. Assessing fitness-for-duty and predicting performance with cognitive neurophysiological measures

    NASA Astrophysics Data System (ADS)

    Smith, Michael E.; Gevins, Alan

    2005-05-01

    Progress is described in developing a novel test of neurocognitive status for fitness-for-duty testing. The Sustained Attention & Memory (SAM) test combines neurophysiologic (EEG) measures of brain activation with performance measures during a psychometric test of sustained attention and working memory, and then gauges changes in neurocognitive status relative to an individual"s normative baseline. In studies of the effects of common psychoactive substances that can affect job performance, including sedating antihistamines, caffeine, alcohol, marijuana, and prescription medications, test sensitivity was greater for the combined neurophysiological and performance measures than for task performance measures by themselves. The neurocognitive effects of overnight sleep deprivation were quite evident, and such effects predicted subsequent performance impairment on a flight simulator task. Sensitivity to diurnal circadian variations was also demonstrated. With further refinement and independent validation, the SAM Test may prove useful for assessing readiness-to-perform in high-asset personnel working in demanding, high risk situations.

  16. Testing the performance of microbiological safety cabinets used in microbiology laboratories in South Korea.

    PubMed

    Hwang, S H; Yi, T W; Cho, K H; Lee, I M; Yoon, C S

    2011-09-01

    To test a performance of the microbiological safety cabinets (MSCs) according to the type of MSCs in microbial laboratories. Tests were carried out to assess the performance of 31 MSCs in 14 different facilities, including six different biological test laboratories in six hospitals and eight different laboratories in three universities. The following tests were performed on the MSCs: the downflow test, intake velocity test, high-efficiency particulate air filter leak test and the airflow smoke pattern test. These performance tests were carried out in accordance with the standard procedures. Only 23% of Class II A1 (8), A2 (19) and unknown MSCs (4) passed these performance tests. The main reasons for the failure of MSCs were inappropriate intake velocity (65%), leakage in the HEPA filter sealing (50%), unbalanced airflow smoke pattern in the cabinets (39%) and inappropriate downflow (27%). This study showed that routine checks of MSCs are important to detect and strengthen the weak spots that frequently develop, as observed during the evaluation of the MSCs of various institutions. Routine evaluation and maintenance of MSCs are critical for optimizing performance. © 2011 The Authors. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.

  17. Do Performance-Based Wheelchair Propulsion Tests Detect Changes Among Manual Wheelchair Users With Spinal Cord Injury During Inpatient Rehabilitation in Quebec?

    PubMed

    Gagnon, Dany H; Roy, Audrey; Verrier, Molly C; Duclos, Cyril; Craven, B Cathy; Nadeau, Sylvie

    2016-07-01

    To quantify and compare the responsiveness and concurrent validity of 3 performance-based manual wheelchair propulsion tests among manual wheelchair users with subacute spinal cord injury (SCI) undergoing inpatient rehabilitation. Quasi-experimental repeated-measures design. Publicly funded comprehensive inpatient SCI rehabilitation program. Consenting adult manual wheelchair users with a subacute SCI admitted and discharged from inpatient rehabilitation (N=14). Participants performed 20-m propulsion at both self-selected natural and maximal speeds, the slalom, and the 6-minute propulsion tests at rehabilitation admission and discharge. Time required to complete the performance-based wheelchair propulsion tests. Standardized response means (SRMs) were computed for each performance test and Pearson correlation coefficients (r) were calculated to explore the associations between performance tests. The slalom (SRM=1.24), 20-m propulsion at maximum speed (SRM=.99), and 6-minute propulsion tests (SRM=.84) were the most responsive. The slalom and 20-m propulsion at maximum speed were strongly correlated at both admission (r=.93) and discharge (r=.92). The slalom and 6-minute propulsion tests best document wheelchair propulsion performance change over the course of inpatient rehabilitation. Adding the 20-m propulsion test performed at maximal speed provides a complementary description of performance change. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  18. Occupational Survey Report, Cardiopulmonary Laboratory, AFSC 4H0X1, OSSN: 2541

    DTIC Science & Technology

    2004-02-01

    patients within facility 97 E0211 Set up humidifiers 97 E0175 Instruct patients in use of incentive spirometers 97 A0031 Obtain sputum samples 97 A0026...D0137 Calibrate pulmonary function testing equipment 100 D0150 Perform routine spirometry tests 100 D0146 Perform lung diffusion tests 100 A0042 Perform...consultations, or procedures 31 D0150 Perform routine spirometry tests 23 35 TABLE A2 REPRESENTATIVE TASKS PERFORMED BY MEMBERS IN THE SUPERVISION AND

  19. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Performance Verification Report: Final Comprehensive Performance Test Report, P/N 1331720-2TST, S/N 105/A1

    NASA Technical Reports Server (NTRS)

    Platt, R.

    1999-01-01

    This is the Performance Verification Report, Final Comprehensive Performance Test (CPT) Report, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A). This specification establishes the requirements for the CPT and Limited Performance Test (LPT) of the AMSU-1A, referred to here in as the unit. The sequence in which the several phases of this test procedure shall take place is shown.

  20. Spatial learning and psychomotor performance of C57BL/6 mice: age sensitivity and reliability of individual differences.

    PubMed

    de Fiebre, Nancyellen C; Sumien, Nathalie; Forster, Michael J; de Fiebre, Christopher M

    2006-09-01

    Two tests often used in aging research, the elevated path test and the Morris water maze test, were examined for their application to the study of brain aging in a large sample of C57BL/6JNia mice. Specifically, these studies assessed: (1) sensitivity to age and the degree of interrelatedness among different behavioral measures derived from these tests, (2) the effect of age on variation in the measurements, and (3) the reliability of individual differences in performance on the tests. Both tests detected age-related deficits in group performance that occurred independently of each other. However, analysis of data obtained on the Morris water maze test revealed three relatively independent components of cognitive performance. Performance in initial acquisition of spatial learning in the Morris maze was not highly correlated with performance during reversal learning (when mice were required to learn a new spatial location), whereas performance in both of those phases was independent of spatial performance assessed during a single probe trial administered at the end of acquisition training. Moreover, impaired performance during initial acquisition could be detected at an earlier age than impairments in reversal learning. There were modest but significant age-related increases in the variance of both elevated path test scores and in several measures of learning in the Morris maze test. Analysis of test scores of mice across repeated testing sessions confirmed reliability of the measurements obtained for cognitive and psychomotor function. Power calculations confirmed that there are sufficiently large age-related differences in elevated path test performance, relative to within age variability, to render this test useful for studies into the ability of an intervention to prevent or reverse age-related deficits in psychomotor performance. Power calculations indicated a need for larger sample sizes for detection of intervention effects on cognitive components of the Morris water maze test, at least when implemented at the ages tested in this study. Variability among old mice in both tests, including each of the various independent measures in the Morris maze, may be useful for elucidating the biological bases of different aspects of dysfunctional brain aging.

  1. 40 CFR 1060.235 - What emission testing must I perform for my application for a certificate of conformity?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false What emission testing must I perform... emission testing must I perform for my application for a certificate of conformity? This section describes the emission testing you must perform to show compliance with the emission standards in subpart B of...

  2. 40 CFR 1060.235 - What emission testing must I perform for my application for a certificate of conformity?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false What emission testing must I perform... emission testing must I perform for my application for a certificate of conformity? This section describes the emission testing you must perform to show compliance with the emission standards in subpart B of...

  3. 40 CFR 1060.235 - What emission testing must I perform for my application for a certificate of conformity?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false What emission testing must I perform... emission testing must I perform for my application for a certificate of conformity? This section describes the emission testing you must perform to show compliance with the emission standards in subpart B of...

  4. 40 CFR 1060.235 - What emission testing must I perform for my application for a certificate of conformity?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false What emission testing must I perform... emission testing must I perform for my application for a certificate of conformity? This section describes the emission testing you must perform to show compliance with the emission standards in subpart B of...

  5. 40 CFR 1060.235 - What emission testing must I perform for my application for a certificate of conformity?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 33 2011-07-01 2011-07-01 false What emission testing must I perform... emission testing must I perform for my application for a certificate of conformity? This section describes the emission testing you must perform to show compliance with the emission standards in subpart B of...

  6. 40 CFR 63.1161 - Performance testing and test methods.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Facilities and Hydrochloric Acid Regeneration Plants § 63.1161 Performance testing and test methods. (a...) Establishment of hydrochloric acid regeneration plant operating parameters. (1) During the performance test for hydrochloric acid regeneration plants, the owner or operator shall establish site-specific operating parameter...

  7. 40 CFR 63.1161 - Performance testing and test methods.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Facilities and Hydrochloric Acid Regeneration Plants § 63.1161 Performance testing and test methods. (a...) Establishment of hydrochloric acid regeneration plant operating parameters. (1) During the performance test for hydrochloric acid regeneration plants, the owner or operator shall establish site-specific operating parameter...

  8. 40 CFR 63.344 - Performance test requirements and test methods.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... blanket type fume suppressants are used to control chromium emissions from a hard chromium electroplating... National Emission Standards for Chromium Emissions From Hard and Decorative Chromium Electroplating and Chromium Anodizing Tanks § 63.344 Performance test requirements and test methods. (a) Performance test...

  9. 40 CFR 63.344 - Performance test requirements and test methods.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... blanket type fume suppressants are used to control chromium emissions from a hard chromium electroplating... National Emission Standards for Chromium Emissions From Hard and Decorative Chromium Electroplating and Chromium Anodizing Tanks § 63.344 Performance test requirements and test methods. (a) Performance test...

  10. 40 CFR 63.344 - Performance test requirements and test methods.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... blanket type fume suppressants are used to control chromium emissions from a hard chromium electroplating... National Emission Standards for Chromium Emissions From Hard and Decorative Chromium Electroplating and Chromium Anodizing Tanks § 63.344 Performance test requirements and test methods. (a) Performance test...

  11. 40 CFR 799.4360 - Tributyl phosphate.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... provisions also apply: (i) Animal selection. Testing shall be performed in laboratory rats. (ii) Duration of... apply: (i) Animal selection. Testing shall be performed in laboratory rats. (ii) Duration of testing...) Animal selection. Testing shall be performed in laboratory rats. (ii) Duration of testing. Animals shall...

  12. Are the General Medical Council's Tests of Competence fair to long standing doctors? A retrospective cohort study.

    PubMed

    Mehdizadeh, Leila; Sturrock, Alison; Dacre, Jane

    2015-04-21

    The General Medical Council's Fitness to Practise investigations may involve a test of competence for doctors with performance concerns. Concern has been raised about the suitability of the test format for doctors who qualified before the introduction of Single Best Answer and Objective Structured Clinical Examination assessments, both of which form the test of competence. This study explored whether the examination formats used in the tests of competence are fair to long standing doctors who have undergone fitness to practise investigation. A retrospective cohort design was used to determine an association between year of primary medical qualification and doctors' test of competence performance. Performance of 95 general practitioners under investigation was compared with a group of 376 volunteer doctors. We analysed performance on knowledge test, OSCE overall, and three individual OSCE stations using Spearman's correlation and regression models. Doctors under investigation performed worse on all test outcomes compared to the comparison group. Qualification year correlated positively with performance on all outcomes except for physical examination (e.g. knowledge test r = 0.48, p < 0.001 and OSCE r = 0.37, p < 0.001). Qualification year was associated with test performance in doctors under investigation even when controlling for sex, ethnicity and qualification region. Regression analyses showed that qualification year was associated with knowledge test, OSCE and communication skills performance of doctors under investigation when other variables were controlled for. Among volunteer doctors this was not the case and their performance was more strongly related to where they qualified and their ethnic background. Furthermore, volunteer doctors who qualified before the introduction of Single Best Answer and OSCE assessments, still outperformed their peers under investigation. Earlier graduates under fitness to practise investigation performed less well on the test of competence than their more recently qualified peers under investigation. The performance of the comparator group tended to stay consistent irrespective of year qualified. Our results suggest that the test format does not disadvantage early qualified doctors. We discuss findings in relation to the GMC's fitness to practise procedures and suggest alternative explanations for the poorer performance of long standing doctors under investigation.

  13. Association between physiological falls risk and physical performance tests among community-dwelling older adults.

    PubMed

    Singh, Devinder K A; Pillai, Sharmila G K; Tan, Sin Thien; Tai, Chu Chiau; Shahar, Suzana

    2015-01-01

    Physical performance and balance declines with aging and may lead to increased risk of falls. Physical performance tests may be useful for initial fall-risk screening test among community-dwelling older adults. Physiological profile assessment (PPA), a composite falls risk assessment tool is reported to have 75% accuracy to screen for physiological falls risk. PPA correlates with Timed Up and Go (TUG) test. However, the association between many other commonly used physical performance tests and PPA is not known. The aim of the present study was to examine the association between physiological falls risk measured using PPA and a battery of physical performance tests. One hundred and forty older adults from a senior citizens club in Kuala Lumpur, Malaysia (94 females, 46 males), aged 60 years and above (65.77±4.61), participated in this cross-sectional study. Participants were screened for falls risk using PPA. A battery of physical performance tests that include ten-step test (TST), short physical performance battery (SPPB), functional reach test (FRT), static balance test (SBT), TUG, dominant hand-grip strength (DHGS), and gait speed test (GST) were also performed. Spearman's rank correlation and binomial logistic regression were performed to examine the significantly associated independent variables (physical performance tests) with falls risk (dependent variable). Approximately 13% older adults were at high risk of falls categorized using PPA. Significant differences (P<0.05) were demonstrated for age, TST, SPPB, FRT, SBT, TUG between high and low falls risk group. A significant (P<0.01) weak correlation was found between PPA and TST (r=0.25), TUG (r=0.27), SBT (r=0.23), SPPB (r=-0.33), and FRT (r=-0.23). Binary logistic regression results demonstrated that SBT measuring postural sways objectively using a balance board was the only significant predictor of physiological falls risk (P<0.05, odds ratio of 2.12). The reference values of physical performance tests in our study may be used as a guide for initial falls screening to categorize high and low physiological falls risk among community-dwelling older adults. A more comprehensive assessment of falls risk can be performed thereafter for more specific intervention of underlying impairments.

  14. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Performance Verification Reports: Final Comprehensive Performance Test Report, P/N: 1356006-1, S.N: 202/A2

    NASA Technical Reports Server (NTRS)

    Platt, R.

    1998-01-01

    This is the Performance Verification Report. the process specification establishes the requirements for the comprehensive performance test (CPT) and limited performance test (LPT) of the earth observing system advanced microwave sounding unit-A2 (EOS/AMSU-A2), referred to as the unit. The unit is defined on drawing 1356006.

  15. Model-Scale Aerodynamic Performance Testing of Proposed Modifications to the NASA Langley Low Speed Aeroacoustic Wind Tunnel

    NASA Technical Reports Server (NTRS)

    Booth, Earl R., Jr.; Coston, Calvin W., Jr.

    2005-01-01

    Tests were performed on a 1/20th-scale model of the Low Speed Aeroacoustic Wind Tunnel to determine the performance effects of insertion of acoustic baffles in the tunnel inlet, replacement of the existing collector with a new collector design in the open jet test section, and addition of flow splitters to the acoustic baffle section downstream of the test section. As expected, the inlet baffles caused a reduction in facility performance. About half of the performance loss was recovered by addition the flow splitters to the downstream baffles. All collectors tested reduced facility performance. However, test chamber recirculation flow was reduced by the new collector designs and shielding of some of the microphones was reduced owing to the smaller size of the new collector. Overall performance loss in the facility is expected to be a 5 percent top flow speed reduction, but the facility will meet OSHA limits for external noise levels and recirculation in the test section will be reduced.

  16. Biorelevant in vitro performance testing of orally administered dosage forms-workshop report.

    PubMed

    Reppas, Christos; Friedel, Horst-Dieter; Barker, Amy R; Buhse, Lucinda F; Cecil, Todd L; Keitel, Susanne; Kraemer, Johannes; Morris, J Michael; Shah, Vinod P; Stickelmeyer, Mary P; Yomota, Chikako; Brown, Cynthia K

    2014-07-01

    Biorelevant in vitro performance testing of orally administered dosage forms has become an important tool for the assessment of drug product in vivo behavior. An in vitro performance test which mimics the intraluminal performance of an oral dosage form is termed biorelevant. Biorelevant tests have been utilized to decrease the number of in vivo studies required during the drug development process and to mitigate the risk related to in vivo bioequivalence studies. This report reviews the ability of current in vitro performance tests to predict in vivo performance and generate successful in vitro and in vivo correlations for oral dosage forms. It also summarizes efforts to improve the predictability of biorelevant tests. The report is based on the presentations at the 2013 workshop, Biorelevant In Vitro Performance Testing of Orally Administered Dosage Forms, in Washington, DC, sponsored by the FIP Dissolution/Drug Release Focus Group in partnership with the American Association of Pharmaceutical Scientists (AAPS) and a symposium at the AAPS 2012 Annual meeting on the same topic.

  17. End-of-test Performance and Wear Characterization of NASA's Evolutionary Xenon Thruster (NEXT) Long-Duration Test

    NASA Technical Reports Server (NTRS)

    Shastry, Rohit; Herman, Daniel Andrew; Soulas, George C.; Patterson, Michael J.

    2014-01-01

    This presentation describes results from the end-of-test performance characterization of NASA's Evolutionary Xenon Thruster (NEXT) Long-Duration Test (LDT). Sub-component performance as well as overall thruster performance is presented and compared to results over the course of the test. Overall wear of critical thruster components is also described, and an update on the first failure mode of the thruster is provided.

  18. Next-day effects of ramelteon (8 mg), zopiclone (7.5 mg), and placebo on highway driving performance, memory functioning, psychomotor performance, and mood in healthy adult subjects.

    PubMed

    Mets, Monique A J; de Vries, Juna M; de Senerpont Domis, Lieke M; Volkerts, Edmund R; Olivier, Berend; Verster, Joris C

    2011-10-01

    To evaluate the next-morning residual effects of ramelteon (8 mg), zopiclone (7.5 mg), and placebo on driving performance, memory functioning, psychomotor performance, and mood in healthy adult subjects following bedtime dosing and a middle of the night awakening. Single-center, randomized, double-blind, double-dummy, placebo-controlled, crossover study. Utrecht University, The Netherlands. 30 healthy volunteers (15 males and 15 females). a single dose of ramelteon (8 mg), zopiclone (7.5 mg), and placebo, administered at bedtime. A balance test was performed at night. Other tests were performed the following morning, 8.5 h after administration. Subjects performed a 100-km highway driving test in normal traffic. Primary outcome measure was the standard deviation of the lateral position (SDLP), i.e., the weaving of the car. After driving, cognitive, memory, and psychomotor tests were performed and mood was assessed. SDLP was significantly increased after the intake of ramelteon (+2.2 cm) and zopiclone (+2.9 cm). Ramelteon and zopiclone produced significant impairment on reaction time (P<0.024) in the Sternberg Memory Scanning Test, slow (P<0.007) and fast (P<0.010) tracking, reaction speed (P<0.015) and tracking (P<0.001) in the Divided Attention Test, and delayed recall (P<0.032) in the Word Learning Test. In contrast to ramelteon, zopiclone additionally impaired performance on the Digit Symbol Substitution Test (P<0.001) and the balance test (P<0.001). Ramelteon (8 mg) and zopiclone (7.5 mg) significantly impaired driving performance, cognitive, memory, and psychomotor performance the morning following bedtime administration. In contrast to zopiclone, ramelteon produced no balance impairments. CLINICAL TRIAL IDENTIFIER: NCT00319215 (www.clinicaltrials.gov).

  19. SWI 1.10 Testing Process

    NASA Technical Reports Server (NTRS)

    Stokes, LeBarian

    2009-01-01

    This procedure establishes a system for performing testing in the Six-Degree-Of-Freedom Dynamic Test System (SDTS). Testing includes development and verification testing of customer supplied Test Articles (TAs) and other testing requirements, as requested. This procedure applies to all SDTS testing operations and equipment. The procedure provides an overview of testing performed in the SDTS including test identification requirements, test planning and procedure development, test and performance inspection, test data analysis, and test report generation.

  20. Consideration of "g" as a Common Antecedent for Cognitive Ability Test Performance, Test Motivation, and Perceived Fairness

    ERIC Educational Resources Information Center

    Reeve, Charlie L.; Lam, Holly

    2007-01-01

    Several different analyses were used to test the hypothesis that test-taking motivation, perceived test fairness, and actual test performance are correlated only because they share a common antecedent. First, hierarchical regressions reveal that initial test performance has a unique influence on non-ability factors even after controlling for…

  1. Defining the Physiological Factors that Contribute to Postflight Changes in Functional Performance

    NASA Technical Reports Server (NTRS)

    Bloomberg, J. J.; Arzeno, N.; Buxton, R.; Feiveson, A. H.; Kofman, I.; Lawrence, E.; Lee, S. M. C.; Mulavara, A. P.; Peters, B. T.; Platts, S. H.; hide

    2009-01-01

    Astronauts experience alterations in multiple physiological systems due to exposure to the microgravity conditions of space flight. These physiological changes include sensorimotor disturbances, cardiovascular deconditioning and loss of muscle mass and strength. These changes might affect the ability of crewmembers to perform critical mission tasks immediately after landing on lunar and Martian surfaces. To date, changes in functional performance have not been systematically studied or correlated with physiological changes. To understand how changes in physiological function impact functional performance an interdisciplinary pre/postflight testing regimen (Functional Task Test, FTT) has been developed that systematically evaluates both astronaut postflight functional performance and related physiological changes. The overall objective of the FTT is to identify the key underlying physiological factors that contribute to performance of functional tests that are representative of critical mission tasks. This study will identify which physiological systems contribute the most to impaired performance on each functional test. This will allow us to identify the physiological systems that play the largest role in decrement in functional performance. Using this information we can then design and implement countermeasures that specifically target the physiological systems most responsible for the altered functional performance associated with space flight. The functional test battery was designed to address high priority tasks identified by the Constellation program as critical for mission success. The set of functional tests making up the FTT include the: 1) Seat Egress and Walk Test, 2) Ladder Climb Test, 3) Recovery from Fall/Stand Test, 4) Rock Translation Test, 5) Jump Down Test, 6) Torque Generation Test, and 7) Construction Activity Board Test. Corresponding physiological measures include assessments of postural and gait control, dynamic visual acuity, fine motor control, plasma volume, orthostatic intolerance, upper and lower body muscle strength, power, fatigue, control and neuromuscular drive. Crewmembers perform both functional and physiological tests before and after short (Shuttle) and long-duration (ISS) space flight. Data are collected on R+0 (Shuttle only), R+1, R+6 and R+30.

  2. Integrated Advance Microwave Sounding Unit-A (AMSU-A). Performance Verification Report: EOS AMSU-A1 and AMSU-A2 Receivers Assemblies

    NASA Technical Reports Server (NTRS)

    2000-01-01

    This test report presents the test data of the EOS AMSU-A Flight Model No.1 (FM-1) receiver subsystem. The tests are performed per the Acceptance Test Procedure for the AMSU-A Reseiver Subsystem, AE-26002/6A. The functional performance tests are conducted either at the component or subsystem level. While the component-level tests are performed over the entire operating temperature range predicted by thermal analysis, the subsystem-level test are conducted at ambient temperature only.

  3. A better state-of-mind: deep breathing reduces state anxiety and enhances test performance through regulating test cognitions in children.

    PubMed

    Khng, Kiat Hui

    2017-11-01

    A pre-test/post-test, intervention-versus-control experimental design was used to examine the effects, mechanisms and moderators of deep breathing on state anxiety and test performance in 122 Primary 5 students. Taking deep breaths before a timed math test significantly reduced self-reported feelings of anxiety and improved test performance. There was a statistical trend towards greater effectiveness in reducing state anxiety for boys compared to girls, and in enhancing test performance for students with higher autonomic reactivity in test-like situations. The latter moderation was significant when comparing high-versus-low autonomic reactivity groups. Mediation analyses suggest that deep breathing reduces state anxiety in test-like situations, creating a better state-of-mind by enhancing the regulation of adaptive-maladaptive thoughts during the test, allowing for better performance. The quick and simple technique can be easily learnt and effectively applied by most children to immediately alleviate some of the adverse effects of test anxiety on psychological well-being and academic performance.

  4. Embedded performance validity testing in neuropsychological assessment: Potential clinical tools.

    PubMed

    Rickards, Tyler A; Cranston, Christopher C; Touradji, Pegah; Bechtold, Kathleen T

    2018-01-01

    The article aims to suggest clinically-useful tools in neuropsychological assessment for efficient use of embedded measures of performance validity. To accomplish this, we integrated available validity-related and statistical research from the literature, consensus statements, and survey-based data from practicing neuropsychologists. We provide recommendations for use of 1) Cutoffs for embedded performance validity tests including Reliable Digit Span, California Verbal Learning Test (Second Edition) Forced Choice Recognition, Rey-Osterrieth Complex Figure Test Combination Score, Wisconsin Card Sorting Test Failure to Maintain Set, and the Finger Tapping Test; 2) Selecting number of performance validity measures to administer in an assessment; and 3) Hypothetical clinical decision-making models for use of performance validity testing in a neuropsychological assessment collectively considering behavior, patient reporting, and data indicating invalid or noncredible performance. Performance validity testing helps inform the clinician about an individual's general approach to tasks: response to failure, task engagement and persistence, compliance with task demands. Data-driven clinical suggestions provide a resource to clinicians and to instigate conversation within the field to make more uniform, testable decisions to further the discussion, and guide future research in this area.

  5. Repeated sprint ability related to recovery time in young soccer players.

    PubMed

    Padulo, J; Tabben, M; Ardigò, L P; Ionel, M; Popa, C; Gevat, C; Zagatto, A M; Dello Iacono, A

    2015-01-01

    This study aimed to describe the influence of recovery duration during a repeated sprint ability (RSA) test (6 × 40 m) by investigating a number of variables, such as general performance, metabolic demand, and muscular stretch-shortening performance. Seventeen male soccer outfield players (16 ± 0 years, 66 ± 10 kg) performed three field shuttle-running tests with 15, 20, and 25-sec recoveries. In addition to specific shuttle test's variables, blood lactate concentration and vertical jump height were assessed. Resulting measures were highly reliable (intra-class correlation coefficient up to 0.86). 25-sec recovery improved test performance (-3% total time from 15-sec to 25-sec recovery), vertical jump height (+7% post-test height from 15-sec to 25-sec recovery), and decreased blood lactate accumulation (-33% post-test from 15-sec to 25-sec recovery). Study findings suggest that metabolic acidosis plays a role in worsening performance and fatigue development during the shuttle test. A 25-sec recovery duration maximized performance, containing metabolic-anaerobic power involvement and muscular stretch-shortening performance deterioration during a RSA test.

  6. The validity of ACT-PEP test scores for predicting academic performance of registered nurses in BSN programs.

    PubMed

    Yang, J C; Noble, J

    1990-01-01

    This study investigated the validity of three American College Testing-Proficiency Examination Program (ACT-PEP) tests (Maternal and Child Nursing, Psychiatric/Mental Health Nursing, Adult Nursing) for predicting the academic performance of registered nurses (RNs) enrolled in bachelor's degree BSN programs nationwide. This study also examined RN students' performance on the ACT-PEP tests by their demographic characteristics: student's age, sex, race, student status (full- or part-time), and employment status (full- or part-time). The total sample for the three tests comprised 2,600 students from eight institutions nationwide. The median correlation coefficients between the three ACT-PEP tests and the semester grade point averages ranged from .36 to .56. Median correlation coefficients increased over time, supporting the stability of ACT-PEP test scores for predicting academic performance over time. The relative importance of selected independent variables for predicting academic performance was also examined; the most important variable for predicting academic performance was typically the ACT-PEP test score. Across the institutions, student demographic characteristics did not contribute significantly to explaining academic performance, over and above ACT-PEP scores.

  7. Extravehicular Activity Testing in Analog Environments: Evaluating the Effects of Center of Gravity and Environment on Human Performance

    NASA Technical Reports Server (NTRS)

    Gernhardt, M.L.; Chappell, S.P.

    2009-01-01

    The EVA Physiology, Systems and Performance (EPSP) Project is performing tests in different analog environments to understand human performance during Extravehicular Activity (EVA) with the aim of developing more safe and efficient systems for lunar exploration missions and the Constellation Program. The project is characterizing human EVA performance in studies using several test beds, including the underwater NASA Extreme Environment Mission Operations (NEEMO) and Neutral Buoyancy Laboratory (NBL) facilities, JSC fs Partial Gravity Simulator (POGO), and the NASA Reduced Gravity Office (RGO) parabolic flight aircraft. Using these varied testing environments, NASA can gain a more complete understanding of human performance issues related to EVA and the limitations of each testing environment. Tests are focused on identifying and understanding the EVA system factors that affect human performance such as center of gravity (CG), inertial mass, ground reaction forces (GRF), suit weight, and suit pressure. The test results will lead to the development of lunar EVA systems operations concepts and design requirements that optimize human performance and exploration capabilities. METHODS: Tests were conducted in the NBL and during NEEMO missions in the NOAA Aquarius Habitat. A reconfigurable back pack with repositionable mass was used to simulate Perfect, Low, Forward, High, Aft and NASA Baseline CG locations. Subjects performed simulated exploration tasks that included ambulation, kneel and recovery, rock pick-up, and shoveling. Testing using POGO, that simulates partial gravity via pneumatic weight offload system and a similar reconfigurable rig, is underway for a subset of the same tasks. Additionally, test trials are being performed on the RGO parabolic flight aircraft. Subject performance was assessed using a modified Cooper-Harper scale to assess operator compensation required to achieve desired performance. All CG locations are based on the assumption of a standardized 6 ft 180 lb subject. RESULTS: The modified Cooper-Harper Scale assesses desired task performance described as performance in a reduced gravity environment as compared to a 1G environment. Modified Cooper-Harper ratings of . 3 indicate no improvements are needed, ratings of 4-6 indicate improvements are desirable, and ratings . 7 indicate improvements are mandatory. DISCUSSION: Differences were noted in suited CH results based on environment at the same CG and suit pressure. Additionally, results suggest that CG location affects unsuited human performance. Subjects preferred locations near their natural CG over those that are high, aft, or a combination of high and aft. Further testing and analyses are planned to compare these unsuited results to suited performance.

  8. Performance evaluation of the solar kinetics T-700 line concentrating solar collector

    NASA Technical Reports Server (NTRS)

    1981-01-01

    A performance evaluation of the solar kinetics T-700 line concentrating solar collector is reported. Collector descriptions, summary, test conditions, test equipment, test requirements and procedures, and an analysis of the various tests performed are described.

  9. Predictive validity of pre-admission assessments on medical student performance.

    PubMed

    Dabaliz, Al-Awwab; Kaadan, Samy; Dabbagh, M Marwan; Barakat, Abdulaziz; Shareef, Mohammad Abrar; Al-Tannir, Mohamad; Obeidat, Akef; Mohamed, Ayman

    2017-11-24

    To examine the predictive validity of pre-admission variables on students' performance in a medical school in Saudi Arabia. In this retrospective study, we collected admission and college performance data for 737 students in preclinical and clinical years. Data included high school scores and other standardized test scores, such as those of the National Achievement Test and the General Aptitude Test. Additionally, we included the scores of the Test of English as a Foreign Language (TOEFL) and the International English Language Testing System (IELTS) exams. Those datasets were then compared with college performance indicators, namely the cumulative Grade Point Average (cGPA) and progress test, using multivariate linear regression analysis. In preclinical years, both the National Achievement Test (p=0.04, B=0.08) and TOEFL (p=0.017, B=0.01) scores were positive predictors of cGPA, whereas the General Aptitude Test (p=0.048, B=-0.05) negatively predicted cGPA. Moreover, none of the pre-admission variables were predictive of progress test performance in the same group. On the other hand, none of the pre-admission variables were predictive of cGPA in clinical years. Overall, cGPA strongly predict-ed students' progress test performance (p<0.001 and B=19.02). Only the National Achievement Test and TOEFL significantly predicted performance in preclinical years. However, these variables do not predict progress test performance, meaning that they do not predict the functional knowledge reflected in the progress test. We report various strengths and deficiencies in the current medical college admission criteria, and call for employing more sensitive and valid ones that predict student performance and functional knowledge, especially in the clinical years.

  10. Predictive validity of pre-admission assessments on medical student performance

    PubMed Central

    Dabaliz, Al-Awwab; Kaadan, Samy; Dabbagh, M. Marwan; Barakat, Abdulaziz; Shareef, Mohammad Abrar; Al-Tannir, Mohamad; Obeidat, Akef

    2017-01-01

    Objectives To examine the predictive validity of pre-admission variables on students’ performance in a medical school in Saudi Arabia.  Methods In this retrospective study, we collected admission and college performance data for 737 students in preclinical and clinical years. Data included high school scores and other standardized test scores, such as those of the National Achievement Test and the General Aptitude Test. Additionally, we included the scores of the Test of English as a Foreign Language (TOEFL) and the International English Language Testing System (IELTS) exams. Those datasets were then compared with college performance indicators, namely the cumulative Grade Point Average (cGPA) and progress test, using multivariate linear regression analysis. Results In preclinical years, both the National Achievement Test (p=0.04, B=0.08) and TOEFL (p=0.017, B=0.01) scores were positive predictors of cGPA, whereas the General Aptitude Test (p=0.048, B=-0.05) negatively predicted cGPA. Moreover, none of the pre-admission variables were predictive of progress test performance in the same group. On the other hand, none of the pre-admission variables were predictive of cGPA in clinical years. Overall, cGPA strongly predict-ed students’ progress test performance (p<0.001 and B=19.02). Conclusions Only the National Achievement Test and TOEFL significantly predicted performance in preclinical years. However, these variables do not predict progress test performance, meaning that they do not predict the functional knowledge reflected in the progress test. We report various strengths and deficiencies in the current medical college admission criteria, and call for employing more sensitive and valid ones that predict student performance and functional knowledge, especially in the clinical years. PMID:29176032

  11. The relationship between the yo-yo tests, anaerobic performance and aerobic performance in young soccer players.

    PubMed

    Karakoç, Barış; Akalan, Cengiz; Alemdaroğlu, Utku; Arslan, Erşan

    2012-12-01

    The purposes of this study were to determine the relationship between performance in the Yo-Yo intermittent recovery test level 1 (YIRT1), the Yo-Yo intermittent recovery test level 2 (YIRT2) and the Yo-Yo endurance test (continuous) (YET) with maximal oxygen uptake (VO2max) and Wingate anaerobic performance (WaNT) test results in young soccer players (age 15.00 ± 0.0 years, body height 176.3 ± 4.2 cm and body mass 68.1 ± 3.6 kg). An ergospirometry device was used during the treadmill test (TRT) to determine VO2max. At the end of the study, significant differences were found between the Yo-Yo tests and TRT in terms of HRmax (TRT = 195,92, YIRT1 = 197,83, YIRT2 = 198,5 YET = 198) (p > 0.05). While there were moderate correlations between VO2max and YIRT 1-2 performances (respectively, r = 0.56, r = 0.53), there was only a weak relationship between VO2max and YET performance (r = 0.43) (distance covered). There were also moderate significant negative correlations between performance in the YIRT2 and peak power measured in the WaNT (r = -0.55), although there were no significant correlations between performance in the three tests and average power. A moderate negative correlation was found between performance in the YIRT2 and Fatigue index (FI) (r = -0,66). In conclusion, the YIRT2 may be a more suitable field test for determining both aerobic and anaerobic performance in soccer players.

  12. The Relationship Between the Yo-Yo Tests, Anaerobic Performance and Aerobic Performance in Young Soccer Players

    PubMed Central

    Karakoç, Barış; Akalan, Cengiz; Alemdaroğlu, Utku; Arslan, Erşan

    2012-01-01

    The purposes of this study were to determine the relationship between performance in the Yo-Yo intermittent recovery test level 1 (YIRT1), the Yo-Yo intermittent recovery test level 2 (YIRT2) and the Yo-Yo endurance test (continuous) (YET) with maximal oxygen uptake (VO2max) and Wingate anaerobic performance (WaNT) test results in young soccer players (age 15.00 ± 0.0 years, body height 176.3 ± 4.2 cm and body mass 68.1 ± 3.6 kg). An ergospirometry device was used during the treadmill test (TRT) to determine VO2max. At the end of the study, significant differences were found between the Yo-Yo tests and TRT in terms of HRmax (TRT = 195,92, YIRT1 = 197,83, YIRT2 = 198,5 YET = 198) (p > 0.05). While there were moderate correlations between VO2max and YIRT 1–2 performances (respectively, r = 0.56, r = 0.53), there was only a weak relationship between VO2max and YET performance (r = 0.43) (distance covered). There were also moderate significant negative correlations between performance in the YIRT2 and peak power measured in the WaNT (r = −0.55), although there were no significant correlations between performance in the three tests and average power. A moderate negative correlation was found between performance in the YIRT2 and Fatigue index (FI) (r = −0,66). In conclusion, the YIRT2 may be a more suitable field test for determining both aerobic and anaerobic performance in soccer players. PMID:23486008

  13. CAN UPPER EXTREMITY FUNCTIONAL TESTS PREDICT THE SOFTBALL THROW FOR DISTANCE: A PREDICTIVE VALIDITY INVESTIGATION

    PubMed Central

    Hanney, William J.; Kolber, Morey J.; Davies, George J.; Riemann, Bryan

    2011-01-01

    Introduction: Understanding the relationships between performance tests and sport activity is important to the rehabilitation specialist. The purpose of this study was two- fold: 1) To identify if relationships exist between tests of upper body strength and power (Single Arm Seated Shot Put, Timed Push-Up, Timed Modified Pull-Up, and The Davies Closed Kinetic Chain Upper Extremity Stability Test, and the softball throw for distance), 2) To determine which variable or group of variables best predicts the performance of a sport specific task (the softball throw for distance). Methods: One hundred eighty subjects (111 females and 69 males, aged 18-45 years) performed the 5 upper extremity tests. The Pearson product moment correlation and a stepwise regression were used to determine whether relationships existed between performance on the tests and which upper extremity test result best explained the performance on the softball throw for distance. Results: There were significant correlations (r=.33 to r=.70, p=0.001) between performance on all of the tests. The modified pull-up test was the best predictor of the performance on the softball throw for distance (r2= 48.7), explaining 48.7% of variation in performance. When weight, height, and age were added to the regression equation the r2 values increased to 64.5, 66.2, and 67.5 respectively. Conclusion: The results of this study indicate that several upper extremity tests demonstrate significant relationships with one another and with the softball throw for distance. The modified pull up test was the best predictor of performance on the softball throw for distance. PMID:21712942

  14. Peripheral visual performance enhancement by neurofeedback training.

    PubMed

    Nan, Wenya; Wan, Feng; Lou, Chin Ian; Vai, Mang I; Rosa, Agostinho

    2013-12-01

    Peripheral visual performance is an important ability for everyone, and a positive inter-individual correlation is found between the peripheral visual performance and the alpha amplitude during the performance test. This study investigated the effect of alpha neurofeedback training on the peripheral visual performance. A neurofeedback group of 13 subjects finished 20 sessions of alpha enhancement feedback within 20 days. The peripheral visual performance was assessed by a new dynamic peripheral visual test on the first and last training day. The results revealed that the neurofeedback group showed significant enhancement of the peripheral visual performance as well as the relative alpha amplitude during the peripheral visual test. It was not the case in the non-neurofeedback control group, which performed the tests within the same time frame as the neurofeedback group but without any training sessions. These findings suggest that alpha neurofeedback training was effective in improving peripheral visual performance. To the best of our knowledge, this is the first study to show evidence for performance improvement in peripheral vision via alpha neurofeedback training.

  15. Predictors of invalid neuropsychological test performance after traumatic brain injury.

    PubMed

    Moore, Bret A; Donders, Jacobus

    2004-10-01

    To investigate the usefulness of the Test of Memory Malingering (TOMM) and the California Verbal Learning Test-Second Edition (CVLT-II) in assessing invalid test performance after traumatic brain injury (TBI). Consecutive 3-year series of rehabilitation referrals (n = 132). Percentage of participants who failed validity criteria was determined. Hierarchical logistic regression analysis and odds ratios were used to identify predictors of invalid test performance. Twenty patients (15%) performed in the invalid range when held to a priori specified criteria for invalid test performance (i.e. TOMM <45/50 on Trial 2 or CVLT-II <15/16 on Forced-Choice recognition trial). Both psychiatric history and financial compensation seeking were associated with an almost 4-fold increase in likelihood of invalid responding. The TOMM and CVLT-II are sensitive to the potential impact of current financial compensation seeking and prior psychiatric history on neuropsychological test performance after TBI.

  16. Development of a test protocol for evaluating EVA glove performance

    NASA Technical Reports Server (NTRS)

    Hinman, Elaine M.

    1992-01-01

    Testing gloved hand performance involves work from several disciplines. Evaluations performed in the course of reenabling a disabled hand, designing a robotic end effector or master controller, or hard-suit design have all yielded relevant information, and, in most cases, produced performance test methods. Most times, these test methods have been primarily oriented toward their parent discipline. For space operations, a comparative test which would provide a way to quantify pressure glove and end effector performance would be useful in dividing tasks between humans and robots. Such a test would have to rely heavily on sensored measurement, as opposed to questionnaires, to produce relevant data. However, at some point human preference would have to be taken into account. This paper presents a methodology for evaluating gloved hand performance which attempts to respond to these issues. Glove testing of a prototype glove design using this method is described.

  17. The Concept of Performance Levels in Criterion-Referenced Assessment.

    ERIC Educational Resources Information Center

    Hewitson, Mal

    The concept of performance levels in criterion-referenced assessment is explored by applying the idea to different types of tests commonly used in schools, mastery tests (including diagnostic tests) and achievement tests. In mastery tests, a threshold performance standard must be established for each criterion. Attainment of this threshold…

  18. Do candidate reactions relate to job performance or affect criterion-related validity? A multistudy investigation of relations among reactions, selection test scores, and job performance.

    PubMed

    McCarthy, Julie M; Van Iddekinge, Chad H; Lievens, Filip; Kung, Mei-Chuan; Sinar, Evan F; Campion, Michael A

    2013-09-01

    Considerable evidence suggests that how candidates react to selection procedures can affect their test performance and their attitudes toward the hiring organization (e.g., recommending the firm to others). However, very few studies of candidate reactions have examined one of the outcomes organizations care most about: job performance. We attempt to address this gap by developing and testing a conceptual framework that delineates whether and how candidate reactions might influence job performance. We accomplish this objective using data from 4 studies (total N = 6,480), 6 selection procedures (personality tests, job knowledge tests, cognitive ability tests, work samples, situational judgment tests, and a selection inventory), 5 key candidate reactions (anxiety, motivation, belief in tests, self-efficacy, and procedural justice), 2 contexts (industry and education), 3 continents (North America, South America, and Europe), 2 study designs (predictive and concurrent), and 4 occupational areas (medical, sales, customer service, and technological). Consistent with previous research, candidate reactions were related to test scores, and test scores were related to job performance. Further, there was some evidence that reactions affected performance indirectly through their influence on test scores. Finally, in no cases did candidate reactions affect the prediction of job performance by increasing or decreasing the criterion-related validity of test scores. Implications of these findings and avenues for future research are discussed. PsycINFO Database Record (c) 2013 APA, all rights reserved

  19. Correlations between Physical Fitness Tests and Performance of Military Tasks: A Systematic Review and Meta-Analyses

    DTIC Science & Technology

    2014-06-30

    U.S. Army Public Health Command Correlations between Physical Fitness Tests and Performance of Military Tasks: A Systematic Review and Meta...30 JUN 2014 2. REPORT TYPE Final 3. DATES COVERE D 4. TITLE AN D SUBTITLE Correlations between Physical Fitness Tests and Performance of... Physical Fitness Test (APFT) and ensure a future test is associated with Soldiers’ performance of common physical job requirements, the USAPHC applied

  20. CF6 jet engine performance improvement program. Short core exhaust nozzle performance improvement concept. [specific fuel consumption reduction

    NASA Technical Reports Server (NTRS)

    Fasching, W. A.

    1979-01-01

    The short core exhaust nozzle was evaluated in CF6-50 engine ground tests including performance, acoustic, and endurance tests. The test results verified the performance predictions from scale model tests. The short core exhaust nozzle provides an internal cruise sfc reduction of 0.9 percent without an increase in engine noise. The nozzle hardware successfully completed 1000 flight cycles of endurance testing without any signs of distress.

  1. Performance Validity Testing in Neuropsychology: Scientific Basis and Clinical Application-A Brief Review.

    PubMed

    Greher, Michael R; Wodushek, Thomas R

    2017-03-01

    Performance validity testing refers to neuropsychologists' methodology for determining whether neuropsychological test performances completed in the course of an evaluation are valid (ie, the results of true neurocognitive function) or invalid (ie, overly impacted by the patient's effort/engagement in testing). This determination relies upon the use of either standalone tests designed for this sole purpose, or specific scores/indicators embedded within traditional neuropsychological measures that have demonstrated this utility. In response to a greater appreciation for the critical role that performance validity issues play in neuropsychological testing and the need to measure this variable to the best of our ability, the scientific base for performance validity testing has expanded greatly over the last 20 to 30 years. As such, the majority of current day neuropsychologists in the United States use a variety of measures for the purpose of performance validity testing as part of everyday forensic and clinical practice and address this issue directly in their evaluations. The following is the first article of a 2-part series that will address the evolution of performance validity testing in the field of neuropsychology, both in terms of the science as well as the clinical application of this measurement technique. The second article of this series will review performance validity tests in terms of methods for development of these measures, and maximizing of diagnostic accuracy.

  2. Computerized Tests of Team Performance and Crew Coordination Suitable for Military/Aviation Settings.

    PubMed

    Lawson, Ben D; Britt, Thomas W; Kelley, Amanda M; Athy, Jeremy R; Legan, Shauna M

    2017-08-01

    The coordination of team effort on shared tasks is an area of inquiry. A number of tests of team performance in challenging environments have been developed without comparison or standardization. This article provides a systematic review of the most accessible and usable low-to-medium fidelity computerized tests of team performance and determines which are most applicable to military- and aviation-relevant research, such as studies of group command, control, communication, and crew coordination. A search was conducted to identify computerized measures of team performance. In addition to extensive literature searches (DTIC, Psychinfo, PubMed), the authors reached out to team performance researchers at conferences and through electronic communication. Identified were 57 potential tests according to 6 specific selection criteria (e.g., the requirement for automated collection of team performance and coordination processes, the use of military-relevant scenarios). The following seven tests (listed alphabetically) were considered most suitable for military needs: Agent Enabled Decision Group Environment (AEDGE), C3Conflict, the C3 (Command, Control, & Communications) Interactive Task for Identifying Emerging Situations (NeoCITIES), Distributed Dynamic Decision Making (DDD), Duo Wondrous Original Method Basic Awareness/Airmanship Test (DuoWOMBAT), the Leader Development Simulator (LDS), and the Planning Task for Teams (PLATT). Strengths and weaknesses of these tests are described and recommendations offered to help researchers identify the test most suitable for their particular needs. Adoption of a few standard computerized test batteries to study team performance would facilitate the evaluation of interventions intended to enhance group performance in multiple challenging military and aerospace operational environments.Lawson BD, Britt TW, Kelley AM, Athy JR, Legan SM. Computerized tests of team performance and crew coordination suitable for military/aviation settings. Aerosp Med Hum Perform. 2017; 88(8):722-729.

  3. Predictive Performance Assessment: Trait and State Dimensions Should not be Confused

    NASA Astrophysics Data System (ADS)

    Pattyn, N.; Migeotte, P.-F.; Morais, J.; Cluydts, R.; Soetens, E.; Meeusen, R.; de Schutter, G.; Nederhof, E.; Kolinsky, R.

    2008-06-01

    One of the major aims of performance investigation is to obtain a measure predicting real-life performance, in order to prevent consequences of a potential decrement. Whereas the predictive validity of such assessment has been extensively described for long-term outcomes, as is the case for testing in selection context, equivalent evidence is lacking regarding the short-term predictive value of cognitive testing, i.e., whether these results reflect real-life performance on an immediately subsequent task. In this series of experiments, we investigated both medium-term and short-term predictive value of psychophysiological testing with regard to real-life performance in two operational settings: military student pilots with regard to their success on an evaluation flight, and special forces candidates with regard to their performance on their training course. Our results showed some relationships between test performance and medium-term outcomes. However, no short-term predictive value could be identified for cognitive testing, despite the fact physiological data showed interesting trends. We recommend a critical distinction between "state" and "trait" dimensions of performance with regard to the predictive value of testing.

  4. The influence of tyre characteristics on measures of rolling performance during cross-country mountain biking.

    PubMed

    Macdermid, Paul William; Fink, Philip W; Stannard, Stephen R

    2015-01-01

    This investigation sets out to assess the effect of five different models of mountain bike tyre on rolling performance over hard-pack mud. Independent characteristics included total weight, volume, tread surface area and tread depth. One male cyclist performed multiple (30) trials of a deceleration field test to assess reliability. Further tests performed on a separate occasion included multiple (15) trials of the deceleration test and six fixed power output hill climb tests for each tyre. The deceleration test proved to be reliable as a means of assessing rolling performance via differences in initial and final speed (coefficient of variation (CV) = 4.52%). Overall differences between tyre performance for both deceleration test (P = 0.014) and hill climb (P = 0.032) were found, enabling significant (P < 0.0001 and P = 0.049) models to be generated, allowing tyre performance prediction based on tyre characteristics. The ideal tyre for rolling and climbing performance on hard-pack surfaces would be to decrease tyre weight by way of reductions in tread surface area and tread depth while keeping volume high.

  5. Reliability and validity of two isometric squat tests.

    PubMed

    Blazevich, Anthony J; Gill, Nicholas; Newton, Robert U

    2002-05-01

    The purpose of the present study was first to examine the reliability of isometric squat (IS) and isometric forward hack squat (IFHS) tests to determine if repeated measures on the same subjects yielded reliable results. The second purpose was to examine the relation between isometric and dynamic measures of strength to assess validity. Fourteen male subjects performed maximal IS and IFHS tests on 2 occasions and 1 repetition maximum (1-RM) free-weight squat and forward hack squat (FHS) tests on 1 occasion. The 2 tests were found to be highly reliable (intraclass correlation coefficient [ICC](IS) = 0.97 and ICC(IFHS) = 1.00). There was a strong relation between average IS and 1-RM squat performance, and between IFHS and 1-RM FHS performance (r(squat) = 0.77, r(FHS) = 0.76; p < 0.01), but a weak relation between squat and FHS test performances (r < 0.55). There was also no difference between observed 1-RM values and those predicted by our regression equations. Errors in predicting 1-RM performance were in the order of 8.5% (standard error of the estimate [SEE] = 13.8 kg) and 7.3% (SEE = 19.4 kg) for IS and IFHS respectively. Correlations between isometric and 1-RM tests were not of sufficient size to indicate high validity of the isometric tests. Together the results suggest that IS and IFHS tests could detect small differences in multijoint isometric strength between subjects, or performance changes over time, and that the scores in the isometric tests are well related to 1-RM performance. However, there was a small error when predicting 1-RM performance from isometric performance, and these tests have not been shown to discriminate between small changes in dynamic strength. The weak relation between squat and FHS test performance can be attributed to differences in the movement patterns of the tests

  6. Solar thermal upper stage technology demonstrator liquid hydrogen storage and feed system test program

    NASA Astrophysics Data System (ADS)

    Cady, E. C.

    1997-01-01

    The Solar Thermal Upper Stage Technology Demonstrator (STUSTD) Liquid Hydrogen Storage and Feed System (LHSFS) Test Program is described. The test program consists of two principal phases. First, an engineering characterization phase includes tests performed to demonstrate and understand the expected tank performance. This includes fill and drain; baseline heat leak; active Thermodynamic Vent System (TVS); and flow tests. After the LHSFS performance is understood and performance characteristics are determined, a 30 day mission simulation test will be conducted. This test will simulate a 30 day transfer mission from low earth orbit (LEO) to geosynchronous equatorial orbit (GEO). Mission performance predictions, based on the results of the engineering characterization tests, will be used to correlate the results of the 30 day mission simulation.

  7. Performance testing for superpave and structural validation.

    DOT National Transportation Integrated Search

    2012-11-01

    The primary objective of this full-scale accelerated pavement testing was to evaluate the performance of unmodified : and polymer modified asphalt binders and to recommend improved specification tests over existing SUperior : PERforming Asphalt PAVEm...

  8. 40 CFR 60.154 - Test methods and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Sewage Treatment Plants § 60.154 Test methods and procedures. (a) In conducting the performance tests required in § 60.8...

  9. Differential effects of scopolamine and amphetamine on microcomputer-based performance tests

    NASA Technical Reports Server (NTRS)

    Kennedy, Robert S.; Odenheimer, Robert C.; Baltzley, Dennis R.; Dunlap, William P.; Wood, Charles D.

    1990-01-01

    The effects of four weekly treatments with scopolamine (1.0 mg) and d-amphetamine (10 mg), separately or in combination, on human performance were investigated in 16 subjects undergoing nine performance tests from a menu of microcomputer-based tests administered after the treatment. It was d-amphetamine treatment that enhanced the results of motor and perceptual speed tests, while scopolamine had no effect on these tests. Two of the five cognitive tests showed reductions with scopolamine. The effects of scopolamine in this and other studies are considered in terms of a model which implies that the magnitude of the performance deficit depends on the performance type and the dosage level of the drug.

  10. Functional performance testing of the hip in athletes: a systematic review for reliability and validity.

    PubMed

    Kivlan, Benjamin R; Martin, Robroy L

    2012-08-01

    The purpose of this study was to systematically review the literature for functional performance tests with evidence of reliability and validity that could be used for a young, athletic population with hip dysfunction. A search of PubMed and SPORTDiscus databases were performed to identify movement, balance, hop/jump, or agility functional performance tests from the current peer-reviewed literature used to assess function of the hip in young, athletic subjects. The single-leg stance, deep squat, single-leg squat, and star excursion balance tests (SEBT) demonstrated evidence of validity and normative data for score interpretation. The single-leg stance test and SEBT have evidence of validity with association to hip abductor function. The deep squat test demonstrated evidence as a functional performance test for evaluating femoroacetabular impingement. Hop/Jump tests and agility tests have no reported evidence of reliability or validity in a population of subjects with hip pathology. Use of functional performance tests in the assessment of hip dysfunction has not been well established in the current literature. Diminished squat depth and provocation of pain during the single-leg balance test have been associated with patients diagnosed with FAI and gluteal tendinopathy, respectively. The SEBT and single-leg squat tests provided evidence of convergent validity through an analysis of kinematics and muscle function in normal subjects. Reliability of functional performance tests have not been established on patients with hip dysfunction. Further study is needed to establish reliability and validity of functional performance tests that can be used in a young, athletic population with hip dysfunction. 2b (Systematic Review of Literature).

  11. Impact of Educational Level on Performance on Auditory Processing Tests.

    PubMed

    Murphy, Cristina F B; Rabelo, Camila M; Silagi, Marcela L; Mansur, Letícia L; Schochat, Eliane

    2016-01-01

    Research has demonstrated that a higher level of education is associated with better performance on cognitive tests among middle-aged and elderly people. However, the effects of education on auditory processing skills have not yet been evaluated. Previous demonstrations of sensory-cognitive interactions in the aging process indicate the potential importance of this topic. Therefore, the primary purpose of this study was to investigate the performance of middle-aged and elderly people with different levels of formal education on auditory processing tests. A total of 177 adults with no evidence of cognitive, psychological or neurological conditions took part in the research. The participants completed a series of auditory assessments, including dichotic digit, frequency pattern and speech-in-noise tests. A working memory test was also performed to investigate the extent to which auditory processing and cognitive performance were associated. The results demonstrated positive but weak correlations between years of schooling and performance on all of the tests applied. The factor "years of schooling" was also one of the best predictors of frequency pattern and speech-in-noise test performance. Additionally, performance on the working memory, frequency pattern and dichotic digit tests was also correlated, suggesting that the influence of educational level on auditory processing performance might be associated with the cognitive demand of the auditory processing tests rather than auditory sensory aspects itself. Longitudinal research is required to investigate the causal relationship between educational level and auditory processing skills.

  12. A Historical Review of Cermet Fuel Development and the Engine Performance Implications

    NASA Technical Reports Server (NTRS)

    Stewart, Mark E.

    2015-01-01

    To better understand Cermet engine performance, examined historical material development reports two issues: High vaporization rate of UO2, High temperature chemical stability of UO2. Cladding and chemical stabilizers each result in large, order of magnitude improvements in high temperature performance. Few samples were tested above 2770 K. Results above 2770 K are ambiguous. Contemporary testing may clarify performance. Cermet sample testing during the NERVA Rover era. Important properties, melting temperature, vaporization rate, strength, Brittle-to-Ductile Transition, cermet sample test results, engine performance, location, peak temperature.

  13. Strapdown gyro test program

    NASA Technical Reports Server (NTRS)

    Irvine, R. B.; Vanalstine, R.

    1977-01-01

    The power spectral noise characteristic performance of the Teledyne two-degree-of-freedom dry tuned gimbal gyroscope was determined. Tests were conducted using a current configuration SDG-5 gyro in conjunction with test equipment with minor modification. Long term bias stability tests were conducted as well as some first difference performance tests. The gyro, test equipment, and the tests performed are described. Results are presented.

  14. 40 CFR 63.11212 - What stack tests and procedures must I use for the performance tests?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 15 2014-07-01 2014-07-01 false What stack tests and procedures must I use for the performance tests? 63.11212 Section 63.11212 Protection of Environment ENVIRONMENTAL... What stack tests and procedures must I use for the performance tests? (a) You must conduct all...

  15. 40 CFR 63.11212 - What stack tests and procedures must I use for the performance tests?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 14 2011-07-01 2011-07-01 false What stack tests and procedures must I use for the performance tests? 63.11212 Section 63.11212 Protection of Environment ENVIRONMENTAL... What stack tests and procedures must I use for the performance tests? (a) You must conduct all...

  16. 40 CFR 63.11212 - What stack tests and procedures must I use for the performance tests?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 15 2012-07-01 2012-07-01 false What stack tests and procedures must I use for the performance tests? 63.11212 Section 63.11212 Protection of Environment ENVIRONMENTAL... What stack tests and procedures must I use for the performance tests? (a) You must conduct all...

  17. 40 CFR 63.11212 - What stack tests and procedures must I use for the performance tests?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 15 2013-07-01 2013-07-01 false What stack tests and procedures must I use for the performance tests? 63.11212 Section 63.11212 Protection of Environment ENVIRONMENTAL... What stack tests and procedures must I use for the performance tests? (a) You must conduct all...

  18. Use of the Marshall Space Flight Center solar simulator in collector performance evaluation

    NASA Technical Reports Server (NTRS)

    Humphries, W. R.

    1978-01-01

    Actual measured values from simulator checkout tests are detailed. Problems encountered during initial startup are discussed and solutions described. Techniques utilized to evaluate collector performance from simulator test data are given. Performance data generated in the simulator are compared to equivalent data generated during natural outdoor testing. Finally, a summary of collector performance parameters generated to date as a result of simulator testing are given.

  19. Effort, symptom validity testing, performance validity testing and traumatic brain injury.

    PubMed

    Bigler, Erin D

    2014-01-01

    To understand the neurocognitive effects of brain injury, valid neuropsychological test findings are paramount. This review examines the research on what has been referred to a symptom validity testing (SVT). Above a designated cut-score signifies a 'passing' SVT performance which is likely the best indicator of valid neuropsychological test findings. Likewise, substantially below cut-point performance that nears chance or is at chance signifies invalid test performance. Significantly below chance is the sine qua non neuropsychological indicator for malingering. However, the interpretative problems with SVT performance below the cut-point yet far above chance are substantial, as pointed out in this review. This intermediate, border-zone performance on SVT measures is where substantial interpretative challenges exist. Case studies are used to highlight the many areas where additional research is needed. Historical perspectives are reviewed along with the neurobiology of effort. Reasons why performance validity testing (PVT) may be better than the SVT term are reviewed. Advances in neuroimaging techniques may be key in better understanding the meaning of border zone SVT failure. The review demonstrates the problems with rigidity in interpretation with established cut-scores. A better understanding of how certain types of neurological, neuropsychiatric and/or even test conditions may affect SVT performance is needed.

  20. Full scale evaluation of diffuser ageing with clean water oxygen transfer tests.

    PubMed

    Krampe, J

    2011-01-01

    Aeration is a crucial part of the biological wastewater treatment in activated sludge systems and the main energy user of WWTPs. Approximately 50 to 60% of the total energy consumption of a WWTP can be attributed to the aeration system. The performance of the aeration system, and in the case of fine bubble diffused aeration the diffuser performance, has a significant impact on the overall plant efficiency. This paper seeks to isolate the changes of the diffuser performance over time by eliminating all other influencing parameters like sludge retention time, surfactants and reactor layout. To achieve this, different diffusers have been installed and tested in parallel treatment trains in two WWTPs. The diffusers have been performance tested in clean water tests under new conditions and after one year of operation. A set of material property tests describing the diffuser membrane quality was also performed. The results showed a significant drop in the performance of the EPDM diffuser in the first year which resulted in similar oxygen transfer efficiency around 16 g/m3/m for all tested systems. Even though the tested silicone diffusers did not show a drop in performance they had a low efficiency in the initial tests. The material properties indicate that the EPDM performance loss is partly due to the washout of additives.

  1. Results of tests performed on the Acoustic Quiet Flow Facility Three-Dimensional Model Tunnel: Report on the Modified D.S.M.A. Design

    NASA Technical Reports Server (NTRS)

    Barna, P. S.

    1996-01-01

    Numerous tests were performed on the original Acoustic Quiet Flow Facility Three-Dimensional Model Tunnel, scaled down from the full-scale plans. Results of tests performed on the original scale model tunnel were reported in April 1995, which clearly showed that this model was lacking in performance. Subsequently this scale model was modified to attempt to possibly improve the tunnel performance. The modifications included: (a) redesigned diffuser; (b) addition of a collector; (c) addition of a Nozzle-Diffuser; (d) changes in location of vent-air. Tests performed on the modified tunnel showed a marked improvement in performance amounting to a nominal increase of pressure recovery in the diffuser from 34 percent to 54 percent. Results obtained in the tests have wider application. They may also be applied to other tunnels operating with an open test section not necessarily having similar geometry as the model under consideration.

  2. Measuring more than we know? An examination of the motivational and situational influences in science achievement

    NASA Astrophysics Data System (ADS)

    Haydel, Angela Michelle

    The purpose of this dissertation was to advance theoretical understanding about fit between the personal resources of individuals and the characteristics of science achievement tasks. Testing continues to be pervasive in schools, yet we know little about how students perceive tests and what they think and feel while they are actually working on test items. This study focused on both the personal (cognitive and motivational) and situational factors that may contribute to individual differences in achievement-related outcomes. 387 eighth grade students first completed a survey including measures of science achievement goals, capability beliefs, efficacy related to multiple-choice items and performance assessments, validity beliefs about multiple-choice items and performance assessments, and other perceptions of these item formats. Students then completed science achievement tests including multiple-choice items and two performance assessments. A sample of students was asked to verbalize both thoughts and feelings as they worked through the test items. These think-alouds were transcribed and coded for evidence of cognitive, metacognitive and motivational engagement. Following each test, all students completed measures of effort, mood, energy level and strategy use during testing. Students reported that performance assessments were more challenging, authentic, interesting and valid than multiple-choice tests. They also believed that comparisons between students were easier using multiple-choice items. Overall, students tried harder, felt better, had higher levels of energy and used more strategies while working on performance assessments. Findings suggested that performance assessments might be more congruent with a mastery achievement goal orientation, while multiple-choice tests might be more congruent with a performance achievement goal orientation. A variable-centered analytic approach including regression analyses provided information about how students, on average, who differed in terms of their teachers' ratings of their science ability, achievement goals, capability beliefs and experiences with science achievement tasks perceived, engaged in, and performed on multiple-choice items and performance assessments. Person-centered analyses provided information about the perceptions, engagement and performance of subgroups of individuals who had different motivational characteristics. Generally, students' personal goals and capability beliefs related more strongly to test perceptions, but not performance, while teacher ratings of ability and test-specific beliefs related to performance.

  3. Arc Jet Screening Tests Of Phase 1 Orbiter Tile Repair Materials and Uncoated RSI High Temperature Emittance Measurements

    NASA Technical Reports Server (NTRS)

    DelPapa, Steven V.

    2005-01-01

    Arc jet tests of candidate tile repair materials and baseline Orbiter uncoated reusable surface insulation (RSI) were performed in the Johnson Space Center's (JSC) Atmospheric Reentry Materials and Structures Evaluation Facility (ARMSEF) from June 23, 2003, through August 19, 2003. These tests were performed to screen candidate tile repair materials by verifying the high temperature performance and determining the thermal stability. In addition, tests to determine the surface emissivity at high temperatures and the geometric shrinkage of bare RSI were performed. In addition, tests were performed to determine the surface emissivity at high temperatures and the geometric shrinkage of uncoated RSI.

  4. 40 CFR 63.5992 - When must I conduct subsequent performance tests?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... performance tests? 63.5992 Section 63.5992 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... CATEGORIES National Emissions Standards for Hazardous Air Pollutants: Rubber Tire Manufacturing General Testing and Initial Compliance Requirements § 63.5992 When must I conduct subsequent performance tests? If...

  5. Blast Performance of Commercially Available Demining Footwear: A Summary of Experimental Trials on Surrogate Legs

    DTIC Science & Technology

    2008-10-01

    Equipment Department of the Dutch Ministry of Defence tasked TNO Defence, Security and Safety to perform AP mine shoe tests to study the protection level...would not provide more insight. Therefore only two tests at 75 g were performed . The test results are summarized in Table 2. The high speed video...be able to better place foot into shoe . But still damage of gelatine prior to test. Pretest x-ray performed to show damage prior to test. The

  6. Verification System: First System-Wide Performance Test

    NASA Astrophysics Data System (ADS)

    Chernobay, I.; Zerbo, L.

    2006-05-01

    System-wide performance tests are essential for the development, testing and evaluation of individual components of the verification system. In addition to evaluating global readiness it helps establishing the practical and financial requirements for eventual operations. The first system-wide performance test (SPT1) was conducted in three phases: - A preparatory phase in May-June 2004 - A performance testing phase in April-June 2005 - An evaluation phase in the last half of 2005. The preparatory phase was developmental in nature. The main objectives for the performance testing phase included establishment of performance baseline under current provisional mode of operation (CTBT/PC- 19/1/Annex II, CTBT/WGB-21/1), examination of established requirements and procedures for operation and maintenance. To establish a system-wide performance baseline the system configuration was fixed for April-May 2005. The third month (June 2005) was used for implementation of 21 test case scenarios to examine either particular operational procedures or the response of the system components to the failures simulated under controlled conditions. A total of 163 stations and 5 certified radionuclide laboratories of International Monitoring System (IMS) participated in the performance testing phase - about 50% of the eventual IMS network. 156 IMS facilities and 40 National Data Centres (NDCs) were connected to the International Data Centre (IDC) via Global Communication Infrastructure (GCI) communication links. In addition, 12 legacy stations in the auxiliary seismic network sent data to the IDC over the Internet. During the performance testing phase, the IDC produced all required products, analysed more than 6100 seismic events and 1700 radionuclide spectra. Performance of all system elements was documented and analysed. IDC products were compared with results of data processing at the NDCs. On the basis of statistics and information collected during the SPT1 a system-wide performance baseline under current guidelines for provisional Operation and Maintenance was established. The test provided feedback for further development of the draft IMS and IDC Operational Manuals and identified priority areas for further system development.

  7. Spelling for the Office. Competency Test Package. Office Occupations. Instructor's Guide.

    ERIC Educational Resources Information Center

    Hines, Donna

    This competency test package, one of a series of test packages for office occupations education, contains a list of performance objectives; a pool of objective questions matched with these performance objectives; a sample, 50-point objective test; and several performance test activities. The package also includes complete directions for the…

  8. Basic Skills for Word Processing. Competency Test Package. Office Occupations. Instructor's Guide.

    ERIC Educational Resources Information Center

    Hines, Donna

    This competency test package, one of a series of test packages for office occupations education, contains a list of performance objectives; a pool of objective questions matched with these performance objectives; a sample, 50-point objective test; and several performance test activities. The package also includes complete directions for the…

  9. Student Assessment System. Domain Referenced Tests. Cosmetology. Volume I: Skills. Georgia Vocational Education Program Articulation.

    ERIC Educational Resources Information Center

    Rice, Linda Maxwell; And Others

    These performance tests for the area of cosmetology consist of a sampling technique (domain referenced tests) which covers all the possible performance situations. When used in total, they may also serve as a comprehensive test. Introductory materials discuss domain referenced testing, determining the domains, and developing performance testing…

  10. Test anxiety, perfectionism, goal orientation, and academic performance.

    PubMed

    Eum, KoUn; Rice, Kenneth G

    2011-03-01

    Dimensions of perfectionism and goal orientation have been reported to have differential relationships with test anxiety. However, the degree of inter-relationship between different dimensions of perfectionism, the 2 × 2 model of goal orientations proposed by Elliot and McGregor, cognitive test anxiety, and academic performance indicators is not known. Based on data from 134 university students, we conducted correlation and regression analyses to test associations between adaptive and maladaptive perfectionism, four types of goal orientations, cognitive test anxiety, and two indicators of academic performance: proximal cognitive performance on a word list recall test and distal academic performance in terms of grade point average. Cognitive test anxiety was inversely associated with both performance indicators, and positively associated with maladaptive perfectionism and avoidance goal orientations. Adaptive and maladaptive perfectionism accounted for significant variance in cognitive test anxiety after controlling for approach and avoidance goal orientations. Overall, nearly 50% of the variance in cognitive test anxiety could be attributed to gender, goal orientations, and perfectionism. Results suggested that students who are highly test anxious are likely to be women who endorse avoidance goal orientations and are maladaptively perfectionistic.

  11. Performance Test on Polymer Waste Form - 12137

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Se Yup

    Polymer solidification was attempted to produce stable waste form for the boric acid concentrates and the dewatered spent resins. The polymer mixture was directly injected into the mold or drum which was packed with the boric acid concentrates and the dewatered spent resins, respectively. The waste form was produced by entirely curing the polymer mixture. A series of performance tests was conducted including compressive strength test, water immersion test, leach test, thermal stability test, irradiation stability test and biodegradation stability test for the polymer waste forms. From the results of the performance tests for the polymer waste forms, it ismore » believed that the polymer waste form is very stable and can satisfy the acceptance criteria for permanent disposal. At present, performance tests with full scale polymer waste forms are being carried out in order to obtain qualification certificate by the regulatory institute in Korea. Polymer waste forms were prepared with the surrogate of boric acid concentrates and the surrogate of spent ion exchange resins respectively. Waste forms were also made in lab scale and in full scale. Lab. scale waste forms were directly subjected to a series of the performance tests. In the case of full scale waste form, the test specimens for the performance test were taken from a part of waste form by coring. A series of performance tests was conducted including compressive strength test, thermal stability test, irradiation stability test and biodegradation stability test, water immersion test, leach test, and free standing water for the polymer waste forms. In addition, a fire resistance test was performed on the waste forms by the requirement of the regulatory institute in Korea. Every polymer waste forms containing the boric acid concentrates and the spent ion exchange resins had exhibited excellent structural integrity of more than 27.58 MPa (4,000 psi) of compressive strength. On thermal stability testing, biodegradation testing and water immersion testing, no degradation was observed in the waste forms. Also, by measuring the compressive strength after these tests, it was confirmed that the structural integrity was still retained. A leach test was performed by using non radioactive cobalt, cesium and strontium. The leaching of cobalt, cesium and strontium from the polymer waste forms was very low. Also, the polymer waste forms were found to possess adequate fire resistance. From the results of the performance tests, it is believed that the polymer waste form is very stable and can satisfy the acceptance criteria for permanent disposal. At present, Performance tests with full scale polymer waste forms are on-going in order to obtain qualification certificate by the regulatory institute in Korea. (authors)« less

  12. Applied Performance Testing. What Is It? Why Use It? (Paper I).

    ERIC Educational Resources Information Center

    McKeegan, Hugh F.

    Applied performance tests (APTs) are defined as tests designed to measure performance, in an actual or simulated setting, of tasks significant to a student's life outside the school or significant to adult life. A number of examples are presented to illustrate which skills may be classified as applied performance (such as file a tax return or…

  13. Web-based application on employee performance assessment using exponential comparison method

    NASA Astrophysics Data System (ADS)

    Maryana, S.; Kurnia, E.; Ruyani, A.

    2017-02-01

    Employee performance assessment is also called a performance review, performance evaluation, or assessment of employees, is an effort to assess the achievements of staffing performance with the aim to increase productivity of employees and companies. This application helps in the assessment of employee performance using five criteria: Presence, Quality of Work, Quantity of Work, Discipline, and Teamwork. The system uses the Exponential Comparative Method and Weighting Eckenrode. Calculation results using graphs were provided to see the assessment of each employee. Programming language used in this system is written in Notepad++ and MySQL database. The testing result on the system can be concluded that this application is correspond with the design and running properly. The test conducted is structural test, functional test, and validation, sensitivity analysis, and SUMI testing.

  14. Association between physiological falls risk and physical performance tests among community-dwelling older adults

    PubMed Central

    Singh, Devinder KA; Pillai, Sharmila GK; Tan, Sin Thien; Tai, Chu Chiau; Shahar, Suzana

    2015-01-01

    Background Physical performance and balance declines with aging and may lead to increased risk of falls. Physical performance tests may be useful for initial fall-risk screening test among community-dwelling older adults. Physiological profile assessment (PPA), a composite falls risk assessment tool is reported to have 75% accuracy to screen for physiological falls risk. PPA correlates with Timed Up and Go (TUG) test. However, the association between many other commonly used physical performance tests and PPA is not known. The aim of the present study was to examine the association between physiological falls risk measured using PPA and a battery of physical performance tests. Methods One hundred and forty older adults from a senior citizens club in Kuala Lumpur, Malaysia (94 females, 46 males), aged 60 years and above (65.77±4.61), participated in this cross-sectional study. Participants were screened for falls risk using PPA. A battery of physical performance tests that include ten-step test (TST), short physical performance battery (SPPB), functional reach test (FRT), static balance test (SBT), TUG, dominant hand-grip strength (DHGS), and gait speed test (GST) were also performed. Spearman’s rank correlation and binomial logistic regression were performed to examine the significantly associated independent variables (physical performance tests) with falls risk (dependent variable). Results Approximately 13% older adults were at high risk of falls categorized using PPA. Significant differences (P<0.05) were demonstrated for age, TST, SPPB, FRT, SBT, TUG between high and low falls risk group. A significant (P<0.01) weak correlation was found between PPA and TST (r=0.25), TUG (r=0.27), SBT (r=0.23), SPPB (r=−0.33), and FRT (r=−0.23). Binary logistic regression results demonstrated that SBT measuring postural sways objectively using a balance board was the only significant predictor of physiological falls risk (P<0.05, odds ratio of 2.12). Conclusion The reference values of physical performance tests in our study may be used as a guide for initial falls screening to categorize high and low physiological falls risk among community-dwelling older adults. A more comprehensive assessment of falls risk can be performed thereafter for more specific intervention of underlying impairments. PMID:26316727

  15. Fine-motor skills testing and prediction of endovascular performance.

    PubMed

    Bech, Bo; Lönn, Lars; Schroeder, Torben V; Ringsted, Charlotte

    2013-12-01

    Performing endovascular procedures requires good control of fine-motor digital movements and hand-eye coordination. Objective assessment of such skills is difficult. Trainees acquire control of catheter/wire movements at various paces. However, little is known to what extent talent plays for novice candidates at entry to practice. To study the association between performance in a novel aptitude test of fine-motor skills and performance in simulated procedures. The test was based on manual course-tracking using a proprietary hand-operated roller-bar device coupled to a personal computer with monitor view rotation. A total of 40 test repetitions were conducted separately with each hand. Test scores were correlated with simulator performance. Group A (n = 14), clinicians with various levels of endovascular experience, performed a simulated procedure of contralateral iliac artery stenting. Group B (n = 19), medical students, performed 10 repetitions of crossing a challenging aortic bifurcation in a simulator. The test score differed markedly between the individuals in both groups, in particular with the non-dominant hand. Group A: the test score with the non-dominant hand correlated significantly with simulator performance assessed with the global rating scale SAVE (R = -0.69, P = 0.007). There was no association observed from performances with the dominant hand. Group B: there was no significant association between the test score and endovascular skills acquisition neither with the dominant nor with the non-dominant hand. Clinicians with increasing levels of endovascular technical experience had developed good fine-motor control of the non-dominant hand, in particular, that was associated with good procedural performance in the simulator. The aptitude test did not predict endovascular skills acquisition among medical students, thus, cannot be suggested for selection of novice candidates. Procedural experience and practice probably supplant the influence of innate abilities (talent) over time.

  16. Using provider performance incentives to increase HIV testing and counseling services in Rwanda.

    PubMed

    de Walque, Damien; Gertler, Paul J; Bautista-Arredondo, Sergio; Kwan, Ada; Vermeersch, Christel; de Dieu Bizimana, Jean; Binagwaho, Agnès; Condo, Jeanine

    2015-03-01

    Paying for performance provides financial rewards to medical care providers for improvements in performance measured by utilization and quality of care indicators. In 2006, Rwanda began a pay for performance scheme to improve health services delivery, including HIV/AIDS services. Using a prospective quasi-experimental design, this study examines the scheme's impact on individual and couples HIV testing. We find a positive impact of pay for performance on HIV testing among married individuals (10.2 percentage points increase). Paying for performance also increased testing by both partners by 14.7 percentage point among discordant couples in which only one of the partners is an AIDS patient. Copyright © 2014. Published by Elsevier B.V.

  17. Evaluating Maintenance Performance: Test Administrator's Manual and Test Subject's Instructions for Criterion Referenced Job Task Performance Tests for Electronic Maintenance. Final Report.

    ERIC Educational Resources Information Center

    Shriver, Edgar L.; And Others

    This document furnishes a complete copy of the Test Subject's Instructions and the Test Administrator's Handbook for a battery of criterion referenced Job Task Performance Tests (JTPT) for electronic maintenance. General information is provided on soldering, Radar Set AN/APN-147(v), Radar Set Special Equipment, Radar Set Bench Test Set-Up, and…

  18. When we test, do we stress? Impact of the testing environment on cortisol secretion and memory performance in older adults.

    PubMed

    Sindi, Shireen; Fiocco, Alexandra J; Juster, Robert-Paul; Pruessner, Jens; Lupien, Sonia J

    2013-08-01

    The majority of studies find that older adults have worse memory performance than young adults. However, contextual features in the testing environment may be perceived as stressful by older adults, increasing their stress hormone levels. Given the evidence that older adults are highly sensitive to the effects of stress hormones (cortisol) on memory performance, it is postulated that a stressful testing environment in older adults can lead to an acute stress response and to memory impairments. The current study compared salivary cortisol levels and memory performance in young and older adults tested in environments manipulated to be stressful (unfavourable condition) or not stressful (favourable condition) for each age group. 28 young adults and 32 older adults were tested in two testing conditions: (1) a condition favouring young adults (constructed to be less stressful for young adults), and (2) a condition favouring older adults (constructed to be less stressful for older adults). The main outcome measure was salivary cortisol levels. Additionally, immediate and delayed memory performances were assessed during each condition. In older adults only, we found significantly high cortisol levels and low memory performance in the condition favouring young adults. In contrast, cortisol levels were lower and memory performance was better when older adults were tested in conditions favouring them. There was no effect of testing condition in young adults. The results demonstrate that older adults' memory performance is highly sensitive to the testing environment. These findings have important implications for both research and clinical settings in which older adults are tested for memory performance. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Test anxiety in relation to measures of cognitive and intellectual functioning.

    PubMed

    Gass, Carlton S; Curiel, Rosie E

    2011-08-01

    The potential impact of test anxiety on cognitive testing was examined in a sample of 300 predominantly male veteran referrals who were administered a comprehensive neuropsychological test battery. Exclusionary criteria included failure on effort testing (n= 14). Level of test anxiety was significantly related to performance on the WAIS-III Working Memory Index (r = -.343, p < .001) but not to scores on the Processing Speed, Perceptual Organization, or Verbal Comprehension indexes. Test anxiety was not related to a global index of neuropsychological performance on the HRNES-R (Average Impairment Scale). Level of education had a collinear relationship with test anxiety in predicting cognitive test performance. Regression analyses revealed a more prominent role for education, indicating the possibility that test anxiety may be a reaction to, more than a cause of, deficient working memory performance. These results suggest that clinicians who use these particular tests should be reluctant to attribute poor test performance to anxiety that occurs during the testing process.

  20. Electrical Characterization of the RCA CDP1822SD Random Access Memory, Volume 1, Appendix a

    NASA Technical Reports Server (NTRS)

    Klute, A.

    1979-01-01

    Electrical characteristization tests were performed on 35 RCA CDP1822SD, 256-by-4-bit, CMOS, random access memories. The tests included three functional tests, AC and DC parametric tests, a series of schmoo plots, rise/fall time screening, and a data retention test. All tests were performed on an automated IC test system with temperatures controlled by a thermal airstream unit. All the functional tests, the data retention test, and the AC and DC parametric tests were performed at ambient temperatures of 25 C, -20 C, -55 C, 85 C, and 125 C. The schmoo plots were performed at ambient temperatures of 25 C, -55 C, and 125 C. The data retention test was performed at 25 C. Five devices failed one or more functional tests and four of these devices failed to meet the expected limits of a number of AC parametric tests. Some of the schmoo plots indicated a small degree of interaction between parameters.

  1. Thermal performance of MSFC hot air collectors under natural and simulated conditions

    NASA Technical Reports Server (NTRS)

    Shih, K., Sr.

    1977-01-01

    The procedures used and the results obtained from an evaluation test program conducted to determine the thermal performance and structural characteristics of selected MSFC--designed hot air collectors under both real and simulated environmental conditions are described. Five collectors were tested in the three phased program. A series of outdoor tests were conducted to determine stagnation temperatures on a typical bright day and to determine each collector's ability to withstand these temperatures. Two of the collectors experienced structural deformation sufficient to eliminate them from the remainder of the test program. A series of outdoor tests to evaluate the thermal performance of collector S/N 10 under certain test conditions were performed followed by a series of indoor tests to evaluate the thermal performance of the collector under closely controlled simulated conditions.

  2. 40 CFR 600.208-12 - Calculation of FTP-based and HFET-based fuel economy, CO2 emissions, and carbon-related exhaust...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., and carbon-related exhaust emissions from the tests performed using gasoline or diesel test fuel. (ii... from the tests performed using alcohol or natural gas test fuel. (b) For each model type, as determined... from the tests performed using gasoline or diesel test fuel. (ii) Calculate the city, highway, and...

  3. 40 CFR 600.208-12 - Calculation of FTP-based and HFET-based fuel economy, CO2 emissions, and carbon-related exhaust...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., and carbon-related exhaust emissions from the tests performed using gasoline or diesel test fuel. (ii... from the tests performed using alcohol or natural gas test fuel. (b) For each model type, as determined... from the tests performed using gasoline or diesel test fuel. (ii) Calculate the city, highway, and...

  4. 40 CFR 600.208-12 - Calculation of FTP-based and HFET-based fuel economy, CO2 emissions, and carbon-related exhaust...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., and carbon-related exhaust emissions from the tests performed using gasoline or diesel test fuel. (ii... from the tests performed using alcohol or natural gas test fuel. (b) For each model type, as determined... from the tests performed using gasoline or diesel test fuel. (ii) Calculate the city, highway, and...

  5. Neurocognitive performance and symptom profiles of Spanish-speaking Hispanic athletes on the ImPACT test.

    PubMed

    Ott, Summer; Schatz, Philip; Solomon, Gary; Ryan, Joseph J

    2014-03-01

    This study documented baseline neurocognitive performance of 23,815 athletes on the Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) test. Specifically, 9,733 Hispanic, Spanish-speaking athletes who completed the ImPACT test in English and 2,087 Hispanic, Spanish-speaking athletes who completed the test in Spanish were compared with 11,955 English-speaking athletes who completed the test in English. Athletes were assigned to age groups (13-15, 16-18). Results revealed a significant effect of language group (p < .001; partial η(2) = 0.06) and age (p < .001; partial η(2) = 0.01) on test performance. Younger athletes performed more poorly than older athletes, and Spanish-speaking athletes completing the test in Spanish scored more poorly than Spanish-speaking and English-speaking athletes completing the test in English, on all Composite scores and Total Symptom scores. Spanish-speaking athletes completing the test in English also performed more poorly than English-speaking athletes completing the test in English on three Composite scores. These differences in performance and reported symptoms highlight the need for caution in interpreting ImPACT test data for Hispanic Americans.

  6. 40 CFR 63.7520 - What performance tests and procedures must I use?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... load while burning the type of fuel or mixture of fuels that have the highest content of chlorine... performance test. (e) You may not conduct performance tests during periods of startup, shutdown, or...

  7. 40 CFR 63.7520 - What performance tests and procedures must I use?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... load while burning the type of fuel or mixture of fuels that have the highest content of chlorine... performance test. (e) You may not conduct performance tests during periods of startup, shutdown, or...

  8. 40 CFR 63.7520 - What performance tests and procedures must I use?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... load while burning the type of fuel or mixture of fuels that have the highest content of chlorine... performance test. (e) You may not conduct performance tests during periods of startup, shutdown, or...

  9. Employment Standards for Australian Urban Firefighters: Part 4: Physical Aptitude Tests and Standards.

    PubMed

    Fullagar, Hugh H K; Sampson, John A; Mott, Brendan J; Burdon, Catriona A; Taylor, Nigel A S; Groeller, Herbert

    2015-10-01

    Firefighter physical aptitude tests were administered to unskilled subjects and operational firefighters to evaluate the impact that testing bias associated with gender, age, activity-specific skills, or task familiarity may have upon establishing performance thresholds. These tests were administered in sequence, simulating hazmat incidents, ventilation fan carriage (stairs), motor-vehicle rescues, bushfire incidents, fire attacks, and a firefighter rescue. Participants included two unskilled samples (N = 14 and 22) and 143 firefighters. Firefighter performance was not significantly different from the unskilled subjects. Participants from both genders passed the test, with scores unrelated to performance skill or age; however, familiarization significantly improved performance when the test was repeated. These outcomes confirmed this test to be gender-, age-, and skill-neutral. Familiarization effects could be removed through performing a single, pre-selection trial of the test battery.

  10. Fighter pilots' heart rate, heart rate variation and performance during an instrument flight rules proficiency test.

    PubMed

    Mansikka, Heikki; Virtanen, Kai; Harris, Don; Simola, Petteri

    2016-09-01

    Increased task demand will increase the pilot mental workload (PMWL). When PMWL is increased, mental overload may occur resulting in degraded performance. During pilots' instrument flight rules (IFR) proficiency test, PMWL is typically not measured. Therefore, little is known about workload during the proficiency test and pilots' potential to cope with higher task demands than those experienced during the test. In this study, fighter pilots' performance and PMWL was measured during a real IFR proficiency test in an F/A-18 simulator. PMWL was measured using heart rate (HR) and heart rate variation (HRV). Performance was rated using Finnish Air Force's official rating scales. Results indicated that HR and HRV differentiate varying task demands in situations where variations in performance are insignificant. It was concluded that during a proficiency test, PMWL should be measured together with the task performance measurement. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Cognitive Determinants of Academic Performance in Nigerian Pharmacy Schools.

    PubMed

    Ubaka, Chukwuemeka M; Sansgiry, Sujit S; Ukwe, Chinwe V

    2015-09-25

    Objective. To evaluate cognitive factors that might influence academic performance of students in Nigerian pharmacy schools. Methods. A cross-sectional, multi-center survey of Nigerian pharmacy students from 7 schools of pharmacy was conducted using 2 validated questionnaires measuring cognitive constructs such as test anxiety, academic competence, test competence, time management, and strategic study habits. Results. Female students and older students scored significantly better on time management skills and study habits, respectively. Test anxiety was negatively associated with academic performance while test competence, academic competence, and time management were positively associated with academic performance. These 4 constructs significantly discriminated between the lower and higher performing students, with the first 2 contributing to the most differences. Conclusion. Test and academic competence, test anxiety, and time management were significant factors associated with low and high academic performance among Nigerian pharmacy students. The study also demonstrated the significant effects of age, gender, and marital status on these constructs.

  12. Cognitive Determinants of Academic Performance in Nigerian Pharmacy Schools

    PubMed Central

    Sansgiry, Sujit S.; Ukwe, Chinwe V.

    2015-01-01

    Objective. To evaluate cognitive factors that might influence academic performance of students in Nigerian pharmacy schools. Methods. A cross-sectional, multi-center survey of Nigerian pharmacy students from 7 schools of pharmacy was conducted using 2 validated questionnaires measuring cognitive constructs such as test anxiety, academic competence, test competence, time management, and strategic study habits. Results. Female students and older students scored significantly better on time management skills and study habits, respectively. Test anxiety was negatively associated with academic performance while test competence, academic competence, and time management were positively associated with academic performance. These 4 constructs significantly discriminated between the lower and higher performing students, with the first 2 contributing to the most differences. Conclusion. Test and academic competence, test anxiety, and time management were significant factors associated with low and high academic performance among Nigerian pharmacy students. The study also demonstrated the significant effects of age, gender, and marital status on these constructs. PMID:27168614

  13. Does Performing Preplacement Workplace Hair Drug Testing Influence US Department of Transportation Random and Postaccident Urine Drug Test Positivity Rates?

    PubMed

    Price, James W

    Does performing pre-employment hair drug testing subsequently affect the prevalence of positive random and postaccident urine drug tests? This cross-sectional study was designed to evaluate the prevalence of positive postaccident and random workplace urine drug tests for companies that perform pre-employment hair and urine drug testing to companies that only perform pre-employment urine drug testing. Fisher exact test of independence indicated no significant difference between pre-employment hair drug testing and overall US Department of Transportation random and postaccident urine drug test positivity rates. The analysis failed to reject the null hypothesis, suggesting that pre-employment hair drug testing had no effect upon random and postaccident urine drug test positivity rates.

  14. GOES Type III Loop Heat Pipe Life Test Results

    NASA Technical Reports Server (NTRS)

    Ottenstein, Laura

    2011-01-01

    The GOES Type III Loop Heat Pipe (LHP) was built as a life test unit for the loop heat pipes on the GOES N-Q series satellites. This propylene LHP was built by Dynatherm Corporation in 2000 and tested continuously for approximately 14 months. It was then put into storage for 3 years. Following the storage period, the LHP was tested at Swales Aerospace to verify that the loop performance hadn t changed. Most test results were consistent with earlier results. At the conclusion of testing at Swales, the LHP was transferred to NASA/GSFC for continued periodic testing. The LHP has been set up for testing in the Thermal Lab at GSFC since 2006. A group of tests consisting of start-ups, power cycles, and a heat transport limit test have been performed every six to nine months since March 2006. Tests results have shown no change in the loop performance over the five years of testing. This presentation will discuss the test hardware, test set-up, and tests performed. Test results to be presented include sample plots from individual tests, along with conductance measurements for all tests performed.

  15. The effects of extended work under sleep deprivation conditions on team-based performance.

    PubMed

    Pilcher, June J; Vander Wood, Melissa A; O'Connell, Kristina L

    2011-07-01

    Teamwork is becoming increasingly common in today's workplaces; however, little research has examined how well teams perform under sleep deprivation conditions. The purpose of the current study was to examine the effect of extended work under sleep deprivation conditions on team performance. A total of 24 participants were sleep deprived for 30 h and completed 16 h of sustained operations during the last portion of the sleep deprivation period. The participants completed the Wombat, a complex task including vigilance and cognitive components, with a partner in four 24-min testing sessions during the sustained operations period. The results indicated that team performance increased during the work period while, within each testing session, team performance on vigilance tasks remained stable and overall performance decreased. The current results suggest that performance on two-person teams results in improved performance but does not fully counteract the decreases in performance within each work period. Performance in two-person teams increased across an extended work shift under sleep deprivation conditions. However, vigilance performance remained stable while overall performance decreased when examining performance in 8-min segments. These results suggest that averaging team-based performance over a longer testing period may mask the negative effects of sleep deprivation. STATEMENT OF RELEVANCE: Performance in two-person teams increased across an extended work shift under sleep deprivation conditions. However, vigilance performance remained stable while overall performance decreased when examining performance in 8-min segments. These results suggest that averaging team-based performance over a longer testing period may mask the negative effects of sleep deprivation.

  16. Reliability, validity and description of timed performance of the Jebsen-Taylor Test in patients with muscular dystrophies.

    PubMed

    Artilheiro, Mariana Cunha; Fávero, Francis Meire; Caromano, Fátima Aparecida; Oliveira, Acary de Souza Bulle; Carvas, Nelson; Voos, Mariana Callil; Sá, Cristina Dos Santos Cardoso de

    2017-12-08

    The Jebsen-Taylor Test evaluates upper limb function by measuring timed performance on everyday activities. The test is used to assess and monitor the progression of patients with Parkinson disease, cerebral palsy, stroke and brain injury. To analyze the reliability, internal consistency and validity of the Jebsen-Taylor Test in people with Muscular Dystrophy and to describe and classify upper limb timed performance of people with Muscular Dystrophy. Fifty patients with Muscular Dystrophy were assessed. Non-dominant and dominant upper limb performances on the Jebsen-Taylor Test were filmed. Two raters evaluated timed performance for inter-rater reliability analysis. Test-retest reliability was investigated by using intraclass correlation coefficients. Internal consistency was assessed using the Cronbach alpha. Construct validity was conducted by comparing the Jebsen-Taylor Test with the Performance of Upper Limb. The internal consistency of Jebsen-Taylor Test was good (Cronbach's α=0.98). A very high inter-rater reliability (0.903-0.999), except for writing with an Intraclass correlation coefficient of 0.772-1.000. Strong correlations between the Jebsen-Taylor Test and the Performance of Upper Limb Module were found (rho=-0.712). The Jebsen-Taylor Test is a reliable and valid measure of timed performance for people with Muscular Dystrophy. Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.

  17. Automobile driver on-road performance test. Volume 3, Examiner's manual

    DOT National Transportation Integrated Search

    1981-09-30

    This report provides procedures for administering and scoring the Automobile Driver On-Road Performance Test (ADOPT). The ADOPT checks 21 separate driving performances. Performances are checked at pre-determined locations along a 10-minute route and ...

  18. Automobile driver on-road performance test. Volume 2, Administrator's manual

    DOT National Transportation Integrated Search

    1981-09-30

    This report provides procedures for setting up, administering, and scoring the Automobile Driver On-Road Performance Test (ADOPT). The ADOPT checks 21 separate driving performances. Performances are checked at pre-determined locations along a 10-minu...

  19. FUNCTIONAL PERFORMANCE TESTING OF THE HIP IN ATHLETES: A SYSTEMATIC REVIEW FOR RELIABILITY AND VALIDITY

    PubMed Central

    Martin, RobRoy L.

    2012-01-01

    Purpose/Background: The purpose of this study was to systematically review the literature for functional performance tests with evidence of reliability and validity that could be used for a young, athletic population with hip dysfunction. Methods: A search of PubMed and SPORTDiscus databases were performed to identify movement, balance, hop/jump, or agility functional performance tests from the current peer-reviewed literature used to assess function of the hip in young, athletic subjects. Results: The single-leg stance, deep squat, single-leg squat, and star excursion balance tests (SEBT) demonstrated evidence of validity and normative data for score interpretation. The single-leg stance test and SEBT have evidence of validity with association to hip abductor function. The deep squat test demonstrated evidence as a functional performance test for evaluating femoroacetabular impingement. Hop/Jump tests and agility tests have no reported evidence of reliability or validity in a population of subjects with hip pathology. Conclusions: Use of functional performance tests in the assessment of hip dysfunction has not been well established in the current literature. Diminished squat depth and provocation of pain during the single-leg balance test have been associated with patients diagnosed with FAI and gluteal tendinopathy, respectively. The SEBT and single-leg squat tests provided evidence of convergent validity through an analysis of kinematics and muscle function in normal subjects. Reliability of functional performance tests have not been established on patients with hip dysfunction. Further study is needed to establish reliability and validity of functional performance tests that can be used in a young, athletic population with hip dysfunction. Level of Evidence: 2b (Systematic Review of Literature) PMID:22893860

  20. 40 CFR 63.827 - Performance test methods.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Performance test methods. 63.827...) National Emission Standards for the Printing and Publishing Industry § 63.827 Performance test methods... test method for determining their values for approval by the Administrator in accordance with § 63.7(f...

  1. 40 CFR 62.14680 - May I conduct performance testing less often?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...

  2. 40 CFR 62.14680 - May I conduct performance testing less often?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...

  3. 40 CFR 62.14680 - May I conduct performance testing less often?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...

  4. 40 CFR 62.14680 - May I conduct performance testing less often?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...

  5. 40 CFR 62.14680 - May I conduct performance testing less often?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...

  6. Play for Performance: Using Computer Games to Improve Motivation and Test-Taking Performance

    ERIC Educational Resources Information Center

    Dennis, Alan R.; Bhagwatwar, Akshay; Minas, Randall K.

    2013-01-01

    The importance of testing, especially certification and high-stakes testing, has increased substantially over the past decade. Building on the "serious gaming" literature and the psychology "priming" literature, we developed a computer game designed to improve test-taking performance using psychological priming. The game primed…

  7. 42 CFR 493.1253 - Standard: Establishment and verification of performance specifications.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... establish performance specifications for any test system used by the laboratory before April 24, 2003. (b)(1... approved test system must do the following before reporting patient test results: (i) Demonstrate that it... following performance characteristics: (A) Accuracy. (B) Precision. (C) Reportable range of test results for...

  8. 42 CFR 493.1253 - Standard: Establishment and verification of performance specifications.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... establish performance specifications for any test system used by the laboratory before April 24, 2003. (b)(1... approved test system must do the following before reporting patient test results: (i) Demonstrate that it... following performance characteristics: (A) Accuracy. (B) Precision. (C) Reportable range of test results for...

  9. 42 CFR 493.1253 - Standard: Establishment and verification of performance specifications.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... establish performance specifications for any test system used by the laboratory before April 24, 2003. (b)(1... approved test system must do the following before reporting patient test results: (i) Demonstrate that it... following performance characteristics: (A) Accuracy. (B) Precision. (C) Reportable range of test results for...

  10. 42 CFR 493.1253 - Standard: Establishment and verification of performance specifications.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... establish performance specifications for any test system used by the laboratory before April 24, 2003. (b)(1... approved test system must do the following before reporting patient test results: (i) Demonstrate that it... following performance characteristics: (A) Accuracy. (B) Precision. (C) Reportable range of test results for...

  11. Morning-evening difference of team-handball-related short-term maximal physical performances in female team handball players.

    PubMed

    Mhenni, Thouraya; Michalsik, Lars Bojsen; Mejri, Mohamed Arbi; Yousfi, Narimen; Chaouachi, Anis; Souissi, Nizar; Chamari, Karim

    2017-05-01

    This study investigated the two different time-of-day effect on team-handball-related short-term maximal physical performances. At two different time-of-day, fifteen young female team handball players performed different physical tests: HandGrip (HG) test, Ball-Throwing Velocity (BTV) test, Modified Agility T-test (MAT) and Repeated Shuttle-Sprint and Jump Ability (RSSJA) test. Rating of perceived exertion (RPE) scale was determined following the termination of the last test. Measurements were performed at two separate testing sessions (i.e., in the morning (7:00-8:30 h) and in the early evening (17:00-18:30 h)) in a randomised and counter-balanced setting on non-consecutive days. The results showed that HG (P = 0.0013), BTV (P = 0.0027) and MAT (P < 0.001) performances were better in the evening compared with the morning. During RSSJA, both best and mean sprint times were shorter in the evening compared to the morning (P < 0.001). Moreover, during the latter test, mean jump performance was higher in the evening compared to the morning (P = 0.026). However, there was no morning-evening difference in the best jump performance during RSSJA. Likewise, jump performance decrement was not affected by the time-of-day of testing. On the other hand, RPE fluctuated, with morning nadirs and afternoon/early evening highest values. The findings suggest that in female team handball players, team-handball-related short-term maximal physical performances were better in the afternoon than in the morning.

  12. Measuring Several Aspects of Attention in One Test: The Factor Structure of Conners's Continuous Performance Test

    ERIC Educational Resources Information Center

    Egeland, Jens; Kovalik-Gran, Iwona

    2010-01-01

    Objective: Continuous performance tests are known to typically measure sustained attention but usually also yield parameters that potentially measure other subprocesses of attention. The aim of the present study was to test the factor structure of the Conners's Continuous Performance Test (CCPT) in a heterogeneous clinical sample consisting of…

  13. Comparing Postsecondary Marketing Student Performance on Computer-Based and Handwritten Essay Tests

    ERIC Educational Resources Information Center

    Truell, Allen D.; Alexander, Melody W.; Davis, Rodney E.

    2004-01-01

    The purpose of this study was to determine if there were differences in postsecondary marketing student performance on essay tests based on test format (i.e., computer-based or handwritten). Specifically, the variables of performance, test completion time, and gender were explored for differences based on essay test format. Results of the study…

  14. The Interaction between Cognitive Test-Taking Strategies, Reading Ability, and Reading Comprehension Test Performance of Iranian EFL Learners

    ERIC Educational Resources Information Center

    Ghafournia, Narjes; Afghari, Akbar

    2013-01-01

    The study scrutinized the probable interaction between using cognitive test-taking strategies, reading proficiency, and reading comprehension test performance of Iranian postgraduate students, who studied English as a foreign language. The study also probed the extent to which the participants' test performance was related to the use of certain…

  15. Computerized Adaptive Performance Evaluation.

    DTIC Science & Technology

    1980-02-01

    based on classical psychological test theory, with the result that the obtained measurements ani statements of achievement or performance have... psychological aspects of the achievement testing environment. Results , C Applications of Item Characteristic Curve Models and Adaptive Testing Strategies ICC...of immediate knowledge of results and adaptive testing on ability test performance (Research Report 76-4). Minneapolis: Department of Psychology

  16. Age and gender differences in correlations of leisure-time, household, and work-related physical activity with physical performance in older Japanese adults.

    PubMed

    Tsunoda, Kenji; Soma, Yuki; Kitano, Naruki; Tsuji, Taishi; Mitsuishi, Yasuhiro; Yoon, Ji-Yeong; Okura, Tomohiro

    2013-10-01

    This study aimed to compare relationships of leisure-time, household, and work-related physical activity (PA) with physical performance by age and gender in older Japanese adults. This cross-sectional study included 525 community-dwelling older adults (73.3 ± 5.2 years) recruited in 2009-2011 in Kasama City, rural Japan. We used the Physical Activity Scale for the Elderly to assess PA variables. Physical performance was evaluated by 11 performance tests: grip strength, single-leg balance, functional reach, sit-and-reach, standing time from long sitting position, sit-to-stand, timed up and go, habitual walk, hand working, and simple and choice reaction times. After adjusting for potential confounders, leisure-time PA in young-old (≤ 74 years) men correlated significantly with eight performance tests (absolute value of Spearman's partial rank correlation coefficient: r = 0.18-0.39), whereas in old-old (≥ 75 years) men it correlated with three performance tests (r = 0.20-0.23). Although leisure-time PA correlated with six performance tests (r = 0.19-0.22) in young-old women, there were no significant correlations between leisure-time PA and performance tests in old-old women. Household PA of young-old men (r = 0.20-0.23) and old-old women (r = 0.26-0.34) correlated with four performance tests. In old-old men and young-old women, no significant correlation was found between household PA and performance tests. Work-related PA did not relate significantly to any performance tests in any groups. This study showed that leisure-time PA is related to physical performance, especially in young-old men and women, and household PA is especially related in young-old men and old-old women. Our findings suggest that supporting strategies for maintaining physical functions would differ by gender and age. © 2013 Japan Geriatrics Society.

  17. 40 CFR 63.7941 - How do I conduct a performance test, design evaluation, or other type of initial compliance...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION... Hazardous Air Pollutants: Site Remediation Performance Tests § 63.7941 How do I conduct a performance test...

  18. 40 CFR 63.7940 - By what date must I conduct performance tests or other initial compliance demonstrations?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS... Pollutants: Site Remediation Performance Tests § 63.7940 By what date must I conduct performance tests or...

  19. MOON-test - determination of motor performance in the pediatric oncology.

    PubMed

    Götte, M; Kesting, S; Albrecht, C; Worth, A; Bös, K; Boos, J

    2013-05-01

    Pediatric cancer patients suffer from various negative consequences due to the disease, the medical therapy and the inactivity during the intensive treatment. Only few studies have systematically identified the adverse effects of cancer on motor performance in childhood. To determine the motor performance of pediatric cancer patients, a motor performance test was developed which is applicable for this specific patient group. Eight test items with reference values for healthy children were merged to the MOON-test (test for motor performance in the oncology). MOON was tested for feasibility and acceptance in 33 patients aged 4-18 years. Feasibility was confirmed for children with different types of cancer (hematological malignancies and solid tumors) and with amputation, endoprosthesis, during aplasia as well as reduced general condition. Furthermore the patients showed a broad acceptance. Based on the study findings, the use of MOON-test as a standardized motor performance diagnostic tool in clinical routine of oncological acute clinics as well as rehabilitation clinics can be recommended.· © Georg Thieme Verlag KG Stuttgart · New York.

  20. Multileaf collimator performance monitoring and improvement using semiautomated quality control testing and statistical process control.

    PubMed

    Létourneau, Daniel; Wang, An; Amin, Md Nurul; Pearce, Jim; McNiven, Andrea; Keller, Harald; Norrlinger, Bernhard; Jaffray, David A

    2014-12-01

    High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process control tools, was developed. The MLC performance monitoring system was used for almost a year on two commercially available MLC models. Control charts were used to establish MLC performance and assess test frequency required to achieve a given level of performance. MLC-related interlocks and servicing events were recorded during the monitoring period and were investigated as indicators of MLC performance variations. The QC test developed as part of the MLC performance monitoring system uses 2D megavoltage images (acquired using an electronic portal imaging device) of 23 fields to determine the location of the leaves with respect to the radiation isocenter. The precision of the MLC performance monitoring QC test and the MLC itself was assessed by detecting the MLC leaf positions on 127 megavoltage images of a static field. After initial calibration, the MLC performance monitoring QC test was performed 3-4 times/week over a period of 10-11 months to monitor positional accuracy of individual leaves for two different MLC models. Analysis of test results was performed using individuals control charts per leaf with control limits computed based on the measurements as well as two sets of specifications of ± 0.5 and ± 1 mm. Out-of-specification and out-of-control leaves were automatically flagged by the monitoring system and reviewed monthly by physicists. MLC-related interlocks reported by the linear accelerator and servicing events were recorded to help identify potential causes of nonrandom MLC leaf positioning variations. The precision of the MLC performance monitoring QC test and the MLC itself was within ± 0.22 mm for most MLC leaves and the majority of the apparent leaf motion was attributed to beam spot displacements between irradiations. The MLC QC test was performed 193 and 162 times over the monitoring period for the studied units and recalibration had to be repeated up to three times on one of these units. For both units, rate of MLC interlocks was moderately associated with MLC servicing events. The strongest association with the MLC performance was observed between the MLC servicing events and the total number of out-of-control leaves. The average elapsed time for which the number of out-of-specification or out-of-control leaves was within a given performance threshold was computed and used to assess adequacy of MLC test frequency. A MLC performance monitoring system has been developed and implemented to acquire high-quality QC data at high frequency. This is enabled by the relatively short acquisition time for the images and automatic image analysis. The monitoring system was also used to record and track the rate of MLC-related interlocks and servicing events. MLC performances for two commercially available MLC models have been assessed and the results support monthly test frequency for widely accepted ± 1 mm specifications. Higher QC test frequency is however required to maintain tighter specification and in-control behavior.

  1. Effect of respiratory muscle training on exercise performance in healthy individuals: a systematic review and meta-analysis.

    PubMed

    Illi, Sabine K; Held, Ulrike; Frank, Irène; Spengler, Christina M

    2012-08-01

    Two distinct types of specific respiratory muscle training (RMT), i.e. respiratory muscle strength (resistive/threshold) and endurance (hyperpnoea) training, have been established to improve the endurance performance of healthy individuals. We performed a systematic review and meta-analysis in order to determine the factors that affect the change in endurance performance after RMT in healthy subjects. A computerized search was performed without language restriction in MEDLINE, EMBASE and CINAHL and references of original studies and reviews were searched for further relevant studies. RMT studies with healthy individuals assessing changes in endurance exercise performance by maximal tests (constant load, time trial, intermittent incremental, conventional [non-intermittent] incremental) were screened and abstracted by two independent investigators. A multiple linear regression model was used to identify effects of subjects' fitness, type of RMT (inspiratory or combined inspiratory/expiratory muscle strength training, respiratory muscle endurance training), type of exercise test, test duration and type of sport (rowing, running, swimming, cycling) on changes in performance after RMT. In addition, a meta-analysis was performed to determine the effect of RMT on endurance performance in those studies providing the necessary data. The multiple linear regression analysis including 46 original studies revealed that less fit subjects benefit more from RMT than highly trained athletes (6.0% per 10 mL · kg⁻¹ · min⁻¹ decrease in maximal oxygen uptake, 95% confidence interval [CI] 1.8, 10.2%; p = 0.005) and that improvements do not differ significantly between inspiratory muscle strength and respiratory muscle endurance training (p = 0.208), while combined inspiratory and expiratory muscle strength training seems to be superior in improving performance, although based on only 6 studies (+12.8% compared with inspiratory muscle strength training, 95% CI 3.6, 22.0%; p = 0.006). Furthermore, constant load tests (+16%, 95% CI 10.2, 22.9%) and intermittent incremental tests (+18.5%, 95% CI 10.8, 26.3%) detect changes in endurance performance better than conventional incremental tests (both p < 0.001) with no difference between time trials and conventional incremental tests (p = 0.286). With increasing test duration, improvements in performance are greater (+0.4% per minute test duration, 95% CI 0.1, 0.6%; p = 0.011) and the type of sport does not influence the magnitude of improvements (all p > 0.05). The meta-analysis, performed on eight controlled trials revealed a significant improvement in performance after RMT, which was detected by constant load tests, time trials and intermittent incremental tests, but not by conventional incremental tests. RMT improves endurance exercise performance in healthy individuals with greater improvements in less fit individuals and in sports of longer durations. The two most common types of RMT (inspiratory muscle strength and respiratory muscle endurance training) do not differ significantly in their effect, while combined inspiratory/expiratory strength training might be superior. Improvements are similar between different types of sports. Changes in performance can be detected by constant load tests, time trials and intermittent incremental tests only. Thus, all types of RMT can be used to improve exercise performance in healthy subjects but care must be taken regarding the test used to investigate the improvements.

  2. Indoor test for thermal performance of the Sunmaster evacuated tube (liquid) solar collector

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The test procedures used to obtain the thermal performance data for a solar collector under simulated conditions are presented. Tests included a stagnation test, a time constant test, a thermal efficiency test, an incident angle modifier test, and a hot fill test. All tests were performed at ambient conditions and the transient effect and the incident angle effect on the collector were determined. The solar collector is a water working fluid type.

  3. Yo-Yo IR2 testing of elite and sub-elite soccer players: performance, heart rate response and correlations to other interval tests.

    PubMed

    Ingebrigtsen, Jørgen; Bendiksen, Mads; Randers, Morten Bredsgaard; Castagna, Carlo; Krustrup, Peter; Holtermann, Andreas

    2012-01-01

    We examined performance, heart rate response and construct validity of the Yo-Yo IR2 test by testing 111 elite and 92 sub-elite soccer players from Norway and Denmark. VO₂max, Yo-Yo IR1 and repeated sprint tests (RSA) (n = 51) and match-analyses (n = 39) were also performed. Yo-Yo IR2 and Yo-Yo IR1 performance was 41 and 25% better (P < 0.01) for elite than sub-elite players, respectively, and heart rate after 2 and 4 min of the Yo-Yo IR2 test was 20 and 15 bpm (9 and 6% HRmax), respectively, lower (P < 0.01) for elite players. RSA performance and VO₂max was not different between competitive levels (P > 0.05). For top-teams, Yo-Yo IR2 performance (28%) and sprinting distance (25%) during match were greater (P < 0.05) than for bottom-teams. For elite and sub-elite players, Yo-Yo IR2 performance was correlated (P < 0.05) with Yo-Yo IR1 performance (r = 0.74 and 0.76) and mean RSA time (r = -0.74 and -0.34). We conclude that the Yo-Yo IR2 test has a high discriminant and concurrent validity, as it discriminates between players of different within- and between-league competitive levels and is correlated to other frequently used intermittent elite soccer tests.

  4. Measurement of Energy Performances for General-Structured Servers

    NASA Astrophysics Data System (ADS)

    Liu, Ren; Chen, Lili; Li, Pengcheng; Liu, Meng; Chen, Haihong

    2017-11-01

    Energy consumption of servers in data centers increases rapidly along with the wide application of Internet and connected devices. To improve the energy efficiency of servers, voluntary or mandatory energy efficiency programs for servers, including voluntary label program or mandatory energy performance standards have been adopted or being prepared in the US, EU and China. However, the energy performance of servers and testing methods of servers are not well defined. This paper presents matrices to measure the energy performances of general-structured servers. The impacts of various components of servers on their energy performances are also analyzed. Based on a set of normalized workload, the author proposes a standard method for testing energy efficiency of servers. Pilot tests are conducted to assess the energy performance testing methods of servers. The findings of the tests are discussed in the paper.

  5. Modified Thermoresponsive Hyperbranched Polymers for Improved Viscosity and Enhanced Lubricity of Engine Oils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cosimbescu, Lelia; Robinson, Joshua W.; Bays, John Timothy

    The manuscript captures the chronological succession of the molecular design progression through multiple architectures and topologies of the polymeric viscosity index improvers and their rheology bench test performance. Tribology testing was also performed on selected analogs and their friction and wear was evaluated. Finally, a top performing polymer was selected for engine testing, scaled-up, and its rheological performance in a complete formulation was assessed. The engine performance of the viscosity index improver was examined against an industry-established baseline.

  6. How Strong and Weak Readers Perform on the Developmental Eye Movement Test (DEM): Norms for Latvian School-Aged Children

    ERIC Educational Resources Information Center

    Serdjukova, Jelena; Ekimane, Lasma; Valeinis, Janis; Skilters, Jurgis; Krumina, Gunta

    2017-01-01

    The aim of our study was to determine DEM test performance norms for school-aged children in Latvia, assess how DEM test results correlate with children's reading rates, compare test performance between strong and weak readers. A modified DEM test and a newly developed reading test were administered to 1487 children during a screening survey. Our…

  7. The relationship between neuropsychological tests of visuospatial function and lobar cortical thickness.

    PubMed

    Zink, Davor N; Miller, Justin B; Caldwell, Jessica Z K; Bird, Christopher; Banks, Sarah J

    2018-06-01

    Tests of visuospatial function are often administered in comprehensive neuropsychological evaluations. These tests are generally considered assays of parietal lobe function; however, the neural correlates of these tests, using modern imaging techniques, are not well understood. In the current study we investigated the relationship between three commonly used tests of visuospatial function and lobar cortical thickness in each hemisphere. Data from 374 patients who underwent a neuropsychological evaluation and MRI scans in an outpatient dementia clinic were included in the analysis. We examined the relationships between cortical thickness, as assessed with Freesurfer, and performance on three tests: Judgment of Line Orientation (JoLO), Block Design (BD) from the Fourth edition of the Wechsler Adult Intelligence Scale, and Brief Visuospatial Memory Test-Revised Copy Trial (BVMT-R-C) in patients who showed overall average performance on these tasks. Using a series of multiple regression models, we assessed which lobe's overall cortical thickness best predicted test performance. Among the individual lobes, JoLO performance was best predicted by cortical thickness in the right temporal lobe. BD performance was best predicted by cortical thickness in the right parietal lobe, and BVMT-R-C performance was best predicted by cortical thickness in the left parietal lobe. Performance on constructional tests of visuospatial function appears to correspond best with underlying cortical thickness of the parietal lobes, while performance on visuospatial judgment tests appears to correspond best to temporal lobe thickness. Future research using voxel-wise and connectivity techniques and including more diverse samples will help further understanding of the regions and networks involved in visuospatial tests.

  8. Thermal Performance Testing of EMU and CSAFE Liquid Cooling Garments

    NASA Technical Reports Server (NTRS)

    Rhodes, Richard; Bue, Grant; Hakam, Mark; Radford, Tamara

    2013-01-01

    Future exploration missions require the development of a new liquid cooling garment (LCG) that offers greater system reliability, is more comfortable, and maximizes thermal performance. To inform the development of a future LCG a thermal performance test was conducted to evaluate three factors: (1) the effect of the thermal comfort undergarment (TCU) on tactile and thermal comfort, (2) the comparable thermal performance of an CSAFE developed engineering evaluation unit (EEU) LCG, which uses a commercial-off-the-shelf (COTS) wicking garment as the base, and (3) the performance of a torso or upper body only LCG configuration to evaluate a proposed auxiliary loop configuration. To evaluate the thermal performance of each configuration a metabolic suit test was conducted, utilizing suited subjects to generate metabolic heat by walking on a treadmill at various speeds. Three (3) test subjects of similar height and weight produced a metabolic load for five tests by either resting (300-600 BTU/hr), walking at a slow pace (1200 BTU/hr), and walking at a brisk pace (2200 BTU/hr). During the test, data was collected that would allow us to track the heat transfer to the LCG and ventilation system to determine the thermal performance of the LCG configurations. Four different test configurations were tested, with one configuration tested twice. The test results show that the CSAFE EEU LCG and EMU LCG had comparable performance. The testing also showed that an auxiliary loop LCG, sized similarly to the shirt-only configuration, should provide adequate cooling for contingency scenarios. Finally, the testing showed the previous analysis that assumed a UA deterioration from the TCU was too conservative and the TCU may prove to be acceptable for future development with additional analysis and testing.

  9. Performance changes and relationship between vertical jump measures and actual sprint performance in elite sprinters with visual impairment throughout a Parapan American games training season

    PubMed Central

    Loturco, Irineu; Winckler, Ciro; Kobal, Ronaldo; Cal Abad, Cesar C.; Kitamura, Katia; Veríssimo, Amaury W.; Pereira, Lucas A.; Nakamura, Fábio Y.

    2015-01-01

    The aims of this study were to estimate the magnitude of variability and progression in actual competitive and field vertical jump test performances in elite Paralympic sprinters with visual impairment in the year leading up to the 2015 Parapan American Games, and to investigate the relationships between loaded and unloaded vertical jumping test results and actual competitive sprinting performance. Fifteen Brazilian Paralympic sprinters with visual impairment attended seven official competitions (four national, two international and the Parapan American Games 2015) between April 2014 and August 2015, in the 100- and 200-m dash. In addition, they were tested in five different periods using loaded (mean propulsive power [MPP] in jump squat [JS] exercise) and unloaded (squat jump [SJ] height) vertical jumps within the 3 weeks immediately prior to the main competitions. The smallest important effect on performances was calculated as half of the within-athlete race-to-race (or test-to-test) variability and a multiple regression analysis was performed to predict the 100- and 200-m dash performances using the vertical jump test results. Competitive performance was enhanced during the Parapan American Games in comparison to the previous competition averages, overcoming the smallest worthwhile enhancement in both the 100- (0.9%) and 200-m dash (1.43%). In addition, The SJ and JS explained 66% of the performance variance in the competitive results. This study showed that vertical jump tests, in loaded and unloaded conditions, could be good predictors of the athletes' sprinting performance, and that during the Parapan American Games the Brazilian team reached its peak competitive performance. PMID:26594181

  10. Predicting the clinical performance of dental students with a manual dexterity test

    PubMed Central

    Lugassy, Diva; Levanon, Yafi; Pilo, Raphael; Shelly, Asaf; Rosen, Gal; Meirowitz, Avi

    2018-01-01

    Dentists must be skilled when using dental mirrors. Working with mirrors requires spatial perception, bimanual coordination, perceptual learning and fine motor skills. Many studies have attempted to determine the predictors of manual skills among pre-clinical students, but consensus has yet to be reached. We hypothesized that valid and reliable occupational therapy test performance regarding indirect vision would differ between dental students and junior dentists and would explain the variance in manual skill performance in pre-clinical courses. To test this hypothesis, we applied the Purdue Pegboard test and O’Connor Tweezer Dexterity test under different conditions of direct and indirect vision. We administered these tests to students in phantom-head academic courses in 2015 and 2016 and to junior dentists. Students performed the tests at three time points: before phantom training (T0), at the end of the training (T1) and in the middle of the following year of study (T2). Dentists performed the same tests twice at 1st and 2nd trials one week apart. The results showed that indirect tasks were significantly more difficult to perform for both groups. These dexterity tests were sensitive enough to detect students’ improvement after phantom training. The dentists’ performances were significantly better than those of students at T0, specifically with regard to the use of tweezers under direct and indirect vision (the O’Connor test). A regression analysis showed that students’ manual grades obtained at the beginning of the phantom course, their performance on the Purdue test using both hands, and their performance on the O’Connor test under indirect vision predicted phantom course success in 80% of cases. The O’Connor test under indirect vision is the most informative means of monitoring and predicting the manual skills required in the pre-clinical year of dentistry studies. PMID:29518127

  11. National Unmanned Aerial System Standardized Performance Testing and Rating (NUSTAR)

    NASA Technical Reports Server (NTRS)

    Kopardekar, Parimal

    2016-01-01

    The overall objective of the NUSTAR Capability is to offer standardized tests and scenario conditions to assess performance of the UAS. The following are goals of the NU-STAR: 1. Create a prototype standardized tests and scenarios that vehicles can be tested against. 2. Identify key performance parameters of all UAS and their standardized measurement strategy. 3. Develop standardized performance reporting method (e.g., consumer report style) to assist prospective buyers. 4. Identify key performance metrics that could be used by judged towards overall safety of the UAS and operations. 5. If vehicle certification standard is made by a regulatory agency, the performance of individual UAS could be compared against the minimum requirement (e.g., sense and avoid detection time, stopping distance, kinetic energy, etc.).

  12. High Speed Prototype Car Test

    NASA Image and Video Library

    2014-01-10

    CAPE CANAVERAL, Fla. - The Performance Power Racing and Hennessey Performance teams pose with a Hennessey Venom GT at the 3.5-mile long runway at the Shuttle Landing Facility at NASA's Kennedy Space Center in Florida. The teams are, from left, Hennessey's John Heinricy, John Hennessey, Brian Smith, Performance Power Racing's Johnny Bohmer, Matt Lundy and Jeff McEachran. The flat concrete runway is one of the few places in the world where high performance automobiles can be tested for aerodynamic and safety designs. Hennessey Performance of Sealy, Texas, worked with Performance Power Racing in West Palm Beach to arrange use of the NASA facility. Performance Power Racing has conducted numerous engineering tests on the runway with a variety of vehicles.

  13. Integration Test of the High Voltage Hall Accelerator System Components

    NASA Technical Reports Server (NTRS)

    Kamhawi, Hani; Haag, Thomas; Huang, Wensheng; Pinero, Luis; Peterson, Todd; Dankanich, John

    2013-01-01

    NASA Glenn Research Center is developing a 4 kilowatt-class Hall propulsion system for implementation in NASA science missions. NASA science mission performance analysis was completed using the latest high voltage Hall accelerator (HiVHAc) and Aerojet-Rocketdyne's state-of-the-art BPT-4000 Hall thruster performance curves. Mission analysis results indicated that the HiVHAc thruster out performs the BPT-4000 thruster for all but one of the missions studied. Tests of the HiVHAc system major components were performed. Performance evaluation of the HiVHAc thruster at NASA Glenn's vacuum facility 5 indicated that thruster performance was lower than performance levels attained during tests in vacuum facility 12 due to the lower background pressures attained during vacuum facility 5 tests when compared to vacuum facility 12. Voltage-Current characterization of the HiVHAc thruster in vacuum facility 5 showed that the HiVHAc thruster can operate stably for a wide range of anode flow rates for discharge voltages between 250 and 600 volts. A Colorado Power Electronics enhanced brassboard power processing unit was tested in vacuum for 1,500 hours and the unit demonstrated discharge module efficiency of 96.3% at 3.9 kilowatts and 650 volts. Stand-alone open and closed loop tests of a VACCO TRL 6 xenon flow control module were also performed. An integrated test of the HiVHAc thruster, brassboard power processing unit, and xenon flow control module was performed and confirmed that integrated operation of the HiVHAc system major components. Future plans include continuing the maturation of the HiVHAc system major components and the performance of a single-string integration test.

  14. 40 CFR 63.1188 - What performance test requirements must I meet?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Performance Tests and Methods § 63.1188 What performance test requirements must I meet? You must meet the... numerical emission limit for PM, CO, or formaldehyde, or at the inlet and outlet of the control device if...

  15. The relationships between pesticide metabolites and neurobehavioral test performance in the third National Health and Nutrition Examination Survey.

    PubMed

    Krieg, Edward F

    2013-01-01

    Regression analysis was used to estimate and test for relationships between urinary pesticide metabolites and neurobehavioral test performance in adults, 20 to 59 years old, participating in the third National Health and Nutrition Examination Survey. The 12 pesticide metabolites included 2 naphthols, 8 phenols, a phenoxyacetic acid, and a pyridinol. The 3 neurobehavioral tests included in the survey were simple reaction time, symbol-digit substitution, and serial digit learning. As the 2,4-dichlorophenol, 2,5-dichlorophenol, and the pentachlorophenol concentrations increased, performance on the serial digit learning test improved. As the 2,5-dichlorophenol concentration increased, performance on the symbol-digit substitution test improved. At low concentrations, the parent compounds of these metabolites may act at acetylcholine and γ-aminobutyric acid synapses in the central nervous system to improve neurobehavioral test performance.

  16. Cryogenic Thermal Performance Testing of Bulk-Fill and Aerogel Insulation Materials

    NASA Technical Reports Server (NTRS)

    Scholtens, B. E.; Fesmire, J. E.; Sass, J. P.; Augustynowicz, S. D.; Heckle, K. W.

    2007-01-01

    The research testing and demonstration of new bulk-fill materials for cryogenic thermal insulation systems was performed by the Cryogenics Test Laboratory at NASA Kennedy Space Center. Thermal conductivity testing under actual-use cryogenic conditions is a key to understanding the total system performance encompassing engineering, economics, and materials factors. A number of bulk fill insulation materials, including aerogel beads, glass bubbles, and perlite powder, were tested using a new cylindrical cryostat. Boundary temperatures for the liquid nitrogen boil-off method were 293 K and 78 K. Tests were performed as a function of cold vacuum pressure from high vacuum to no vacuum conditions. Results are compared with other complementary test methods in the range of 300 K to 20 K. Various testing techniques are shown to be required to obtain a complete understanding of the operating performance of a material and to provide data for answers to design engineering questions.

  17. Affordable Electro-Magnetic Interference (EMI) Testing on Large Space Vehicles

    NASA Technical Reports Server (NTRS)

    Aldridge, Edward; Curry, Bruce; Scully, Robert

    2015-01-01

    Objective: Perform System-Level EMI testing of the Orion Exploration Flight Test-1 (EFT-1) spacecraft in situ in the Kennedy Space Center's Neil Armstrong Operations & Checkout (O&C) Facility in 6 days. The only way to execute the system-level EMI testing and meet this schedule challenge was to perform the EMI testing in situ in the Final Assembly & System Test (FAST) Cell in a reverberant mode, not the direct illumination mode originally planned. This required the unplanned construction of a Faraday Cage around the vehicle and FAST Cell structure. The presence of massive steel platforms created many challenges to developing an efficient screen room to contain the RF energy and yield an effective reverberant chamber. An initial effectiveness test showed marginal performance, but improvements implemented afterward resulted in the final test performing surprisingly well! The paper will explain the design, the challenges, and the changes that made the difference in performance!

  18. The Influence of Body Mass on Physical Fitness Test Performance in Male Firefighter Applicants.

    PubMed

    Phillips, Devin B; Scarlett, Michael P; Petersen, Stewart R

    2017-11-01

    The influence of body mass on test performance was investigated in 414 male firefighter applicants who completed a maximal treadmill test and five task-simulation tests while dressed in fire protective ensemble. Subjects were assigned to six mass categories from less than 70 kg to more than 110 kg, in 10 kg increments (n = 69 in each). Treadmill performance was lower (P < 0.05) in the two heaviest groups. Charged hose advance time was slower in the two lightest groups. The lightest group had slower times for weighted sled pull, forcible entry, and victim rescue tests. The heaviest group was slower on the ladder climb test. Lighter subjects had a small advantage in endurance-oriented tests while higher mass appeared to improve performance slightly in strength-oriented tests. However, mass explained only 4% to 19% of the variance in performance.

  19. Butyl rubber O-ring seals: Revision of test procedures for stockpile materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Domeier, L.A.; Wagter, K.R.

    1996-12-01

    Extensive testing showed little correlation between test slab and O-ring performance. New procedures, comparable to those used with the traditional test slabs, were defined for hardness, compression set, and tensile property testing on sacrificial O-ring specimens. Changes in target performance values were made as needed and were, in one case, tightened to reflect the O-ring performance data. An additional study was carried out on O-ring and slab performance vs cure cycle and showed little sensitivity of material performance to large changes in curing time. Aging and spectra of certain materials indicated that two sets of test slabs from current vendormore » were accidently made from EPDM rather than butyl rubber. Random testing found no O-rings made from EPDM. As a result, and additional spectroscope test will be added to the product acceptance procedures to verify the type of rubber compound used.« less

  20. An Occupational Performance Test Validation Program for Fire Fighters at the Kennedy Space Center

    NASA Technical Reports Server (NTRS)

    Schonfeld, Brian R.; Doerr, Donald F.; Convertino, Victor A.

    1990-01-01

    We evaluated performance of a modified Combat Task Test (CTT) and of standard fitness tests in 20 male subjects to assess the prediction of occupational performance standards for Kennedy Space Center fire fighters. The CTT consisted of stair-climbing, a chopping simulation, and a victim rescue simulation. Average CTT performance time was 3.61 +/- 0.25 min (SEM) and all CTT tasks required 93% to 97% maximal heart rate. By using scores from the standard fitness tests, a multiple linear regression model was fitted to each parameter: the stairclimb (r(exp 2) = .905, P less than .05), the chopping performance time (r(exp 2) = .582, P less than .05), the victim rescue time (r(exp 2) = .218, P = not significant), and the total performance time (r(exp 2) = .769, P less than .05). Treadmill time was the predominant variable, being the major predictor in two of four models. These results indicated that standardized fitness tests can predict performance on some CTT tasks and that test predictors were amenable to exercise training.

  1. Physiological Factors Contributing to Postflight Changes in Functional Performance

    NASA Technical Reports Server (NTRS)

    Bloomberg, J. J.; Feedback, D. L.; Feiverson, A. H.; Lee, S. M. C.; Mulavara, A. P.; Peters, B. T.; Platts, S. H.; Reschke, M. F.; Ryder, J.; Spiering, B. A.; hide

    2009-01-01

    Astronauts experience alterations in multiple physiological systems due to exposure to the microgravity conditions of space flight. These physiological changes include sensorimotor disturbances, cardiovascular deconditioning and loss of muscle mass and strength. These changes might affect the ability of crewmembers to perform critical mission tasks immediately after landing on lunar and Martian surfaces. To date, changes in functional performance have not been systematically studied or correlated with physiological changes. To understand how changes in physiological function impact functional performance an interdisciplinary pre/postflight testing regimen (Functional Task Test, FTT) has been developed that systematically evaluates both astronaut postflight functional performance and related physiological changes. The overall objectives of the FTT are to: Develop a set of functional tasks that represent critical mission tasks for Constellation. Determine the ability to perform these tasks after flight. Identify the key physiological factors that contribute to functional decrements. Use this information to develop targeted countermeasures. The functional test battery was designed to address high priority tasks identified by the Constellation program as critical for mission success. The set of functional tests making up the FTT include the: 1) Seat Egress and Walk Test, 2) Ladder Climb Test, 3) Recovery from Fall/Stand Test, 4) Rock Translation Test, 5) Jump Down Test, 6) Torque Generation Test, and 7) Construction Activity Board Test. Corresponding physiological measures include assessments of postural and gait control, dynamic visual acuity, fine motor control, plasma volume, orthostatic intolerance, upper and lower body muscle strength, power, fatigue, control and neuromuscular drive. Crewmembers will perform both functional and physiological tests before and after short (Shuttle) and long-duration (ISS) space flight. Data will be collected on R+0 (Shuttle only), R+1, R+6 and R+30. Using a multivariate regression model we will identify which physiological systems contribute the most to impaired performance on each functional test. This will allow us to identify the physiological systems that play the largest role in decrement in functional performance. Using this information we can then design and implement countermeasures that specifically target the physiological systems most responsible for the altered functional performance associated with space flight.

  2. EFFECT OF ATHLETIC TAPING AND KINESIOTAPING® ON MEASUREMENTS OF FUNCTIONAL PERFORMANCE IN BASKETBALL PLAYERS WITH CHRONIC INVERSION ANKLE SPRAINS

    PubMed Central

    Karatas, Nihan; Baltaci, Gul

    2012-01-01

    Background: Chronic inversion ankle sprains are common in basketball players. The effect of taping on functional performance is disputed in the literature. Kinesiotaping® (KT®) is a new method that is being used as both a therapeutic and performance enhancement tool. To date, it appears that no study has investigated the effect of ankle KT® on functional performance. Purpose: To investigate the effects of different types of taping (KT® using Kinesio Tex®, athletic taping) on functional performance in athletes with chronic inversion sprains of the ankle. Study Design: Crossover Study Design Methods: Fifteen male basketball players with chronic inversion ankle sprains between the ages of 18 and 22 participated in this study. Functional performance tests (Hopping test by Amanda et al, Single Limb Hurdle Test, Standing Heel Rise test, Vertical Jump Test, The Star Excursion Balance Test [SEBT] and Kinesthetic Ability Trainer [KAT] Test) were used to quantify agility, endurance, balance, and coordination. These tests were conducted four times at one week intervals using varied conditions: placebo tape, without tape, standard athletic tape, and KT®. One-way ANOVA tests were used to examine difference in measurements between conditions. Bonferroni correction was applied to correct for repeated testing. Results: There were no significant differences among the results obtained using the four conditions for SEBT (anterior p=0.0699; anteromedial p=0.126; medial p=0.550; posteromedial p=0.587; posterior p=0.754; posterolateral p=0.907; lateral p=0.124; anterolateral p=0.963) and the KAT dynamic measurement (p=0.388). Faster performance times were measured with KT® and athletic tape in single limb hurdle test when compared to placebo and non-taped conditions (Athletic taping- placebo taping: p=0.03; athletic taping- non tape p=0.016;KT®- Placebo taping p=0.042; KT®-Non tape p=0.016). In standing heel rise test and vertical jump test, athletic taping led to decreased performance. (Standing heel rise test: Athletic taping- placebo taping p=0.035; athletic taping- non tape p=0.043; athletic tape- KT® p<0.001) (Vertical jump test: Athletic taping- placebo taping p=0.002: athletic taping- non tape p=0.002; KT®- athletic tape p<0.001) Conclusion: Kinesiotaping® had no negative effects on a battery of functional performance tests and improvements were seen in some functional performance tests. Clinical Relevance: Ankle taping using Kinesio Tex® Tape did not inhibit functional performance. PMID:22530190

  3. Effect of athletic taping and kinesiotaping® on measurements of functional performance in basketball players with chronic inversion ankle sprains.

    PubMed

    Bicici, Seda; Karatas, Nihan; Baltaci, Gul

    2012-04-01

    Chronic inversion ankle sprains are common in basketball players. The effect of taping on functional performance is disputed in the literature. Kinesiotaping® (KT®) is a new method that is being used as both a therapeutic and performance enhancement tool. To date, it appears that no study has investigated the effect of ankle KT® on functional performance. To investigate the effects of different types of taping (KT® using Kinesio Tex®, athletic taping) on functional performance in athletes with chronic inversion sprains of the ankle. Crossover Study Design Fifteen male basketball players with chronic inversion ankle sprains between the ages of 18 and 22 participated in this study. Functional performance tests (Hopping test by Amanda et al, Single Limb Hurdle Test, Standing Heel Rise test, Vertical Jump Test, The Star Excursion Balance Test [SEBT] and Kinesthetic Ability Trainer [KAT] Test) were used to quantify agility, endurance, balance, and coordination. These tests were conducted four times at one week intervals using varied conditions: placebo tape, without tape, standard athletic tape, and KT®. One-way ANOVA tests were used to examine difference in measurements between conditions. Bonferroni correction was applied to correct for repeated testing. There were no significant differences among the results obtained using the four conditions for SEBT (anterior p=0.0699; anteromedial p=0.126; medial p=0.550; posteromedial p=0.587; posterior p=0.754; posterolateral p=0.907; lateral p=0.124; anterolateral p=0.963) and the KAT dynamic measurement (p=0.388). Faster performance times were measured with KT® and athletic tape in single limb hurdle test when compared to placebo and non-taped conditions (Athletic taping- placebo taping: p=0.03; athletic taping- non tape p=0.016;KT®- Placebo taping p=0.042; KT®-Non tape p=0.016). In standing heel rise test and vertical jump test, athletic taping led to decreased performance. (Standing heel rise test: Athletic taping- placebo taping p=0.035; athletic taping- non tape p=0.043; athletic tape- KT® p<0.001) (Vertical jump test: Athletic taping- placebo taping p=0.002: athletic taping- non tape p=0.002; KT®- athletic tape p<0.001) Kinesiotaping® had no negative effects on a battery of functional performance tests and improvements were seen in some functional performance tests. Ankle taping using Kinesio Tex® Tape did not inhibit functional performance.

  4. Performance evaluation of a second-generation elastic loop mobility system

    NASA Technical Reports Server (NTRS)

    Melzer, K. J.; Swanson, G. D.

    1974-01-01

    Tests were conducted to evaluate the mobility performance of a second-generation Elastic Loop Mobility System (ELMS II). Performance on level test lanes and slopes of lunar soil simulant (LSS) and obstacle-surmounting and crevasse-crossing capabilities were investigated. In addition, internal losses and contact pressure distributions were evaluated. To evaluate the soft-soil performance, two basic soil conditions were tested: loose (LSS1) and dense (LSS5). These conditions embrace the spectrum of soil strengths tested during recent studies for NASA related to the mobility performance of the LRV. Data indicated that for the tested range of the various performance parameters, performance was independent of unit load (contact pressure) and ELMS II drum angular velocity, but was influenced by soil strength and ELMS pitch mode. Power requirements were smaller at a given system output for dense soil than for loose soil. The total system output in terms of pull developed or slope-climbing capability was larger for the ELMS II operating in restrained-pitch mode than in free-pitch mode.

  5. Does increased effort compensate for performance debilitating test anxiety?

    PubMed

    Putwain, David W; Symes, Wendy

    2018-05-24

    It is well established that test anxiety is negatively related to examination performance. Based on attentional control theory, the aim of this study was to examine whether increased effort can protect against performance debilitating test anxiety. Four hundred and sixty-six participants (male = 228; 48.9%; White = 346, 74.3%; mean age = 15.7 years) completed self-report measures of test anxiety and effort that were matched to performance on a high-stakes secondary school examination. The worry and bodily symptoms components of test anxiety were negatively, and effort, positively related to examination performance. Effort moderated the negative relation between bodily symptoms and examination performance. At low effort, the negative relationship was amplified and at high effort was attenuated. Compensatory effort protects performance against bodily symptoms but not worry. It is possible that the cognitive load on working memory arising from the combination of worry and examination demands may be too high to be compensated by effort. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  6. Strain energy release rate as a function of temperature and preloading history utilizing the edge delamination fatique test method

    NASA Technical Reports Server (NTRS)

    Zimmerman, Richard S.; Adams, Donald F.

    1989-01-01

    Static laminate and tension-tension fatigue tests of IM7/8551-7 composite materials was performed. The Edge Delamination Test (EDT) was utilized to evaluate the temperature and preloading history effect on the critical strain energy release rate. Static and fatigue testing was performed at room temperature and 180 F (82 C). Three preloading schemes were used to precondition fatigue test specimens prior to performing the normal tension-tension fatigue EDT testing. Computer software was written to perform all fatigue testing while monitoring the dynamic modulus to detect the onset of delamination and record the test information for later retrieval and reduction.

  7. Do Maximal Roller Skiing Speed and Double Poling Performance Predict Youth Cross-Country Skiing Performance?

    PubMed Central

    Stöggl, Roland; Müller, Erich; Stöggl, Thomas

    2017-01-01

    The aims of the current study were to analyze whether specific roller skiing tests and cycle length are determinants of youth cross-country (XC) skiing performance, and to evaluate sex specific differences by applying non-invasive diagnostics. Forty-nine young XC skiers (33 boys; 13.8 ± 0.6 yrs and 16 girls; 13.4 ± 0.9 yrs) performed roller skiing tests consisting of both shorter (50 m) and longer durations (575 m). Test results were correlated with on snow XC skiing performance (PXC) based on 3 skating and 3 classical distance competitions (3 to 6 km). The main findings of the current study were: 1) Anthropometrics and maturity status were related to boys’, but not to girls’ PXC; 2) Significant moderate to acceptable correlations between girls’ and boys’ short duration maximal roller skiing speed (double poling, V2 skating, leg skating) and PXC were found; 3) Boys’ PXC was best predicted by double poling test performance on flat and uphill, while girls’ performance was mainly predicted by uphill double poling test performance; 4) When controlling for maturity offset, boys’ PXC was still highly associated with the roller skiing tests. The use of simple non-invasive roller skiing tests for determination of PXC represents practicable support for ski clubs, schools or skiing federations in the guidance and evaluation of young talent. Key points Double poling tests on flat and uphill terrain and short duration maximal speed tests were the highest cross-country skiing predicting factors in girls and boys. Only in the boys there was an effect of maturation on the performance outcomes, pointing out that girls seem to be almost fully matured at the age of 13 in contrast to the boys. Roller skiing tests over short distance (50-m) and longer distance 225 m and 350 m are stable and valid measures and suitable for performance prediction in youth cross-country skiers. PMID:28912656

  8. SAN/CXFS test report to LLNL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruwart, T M; Eldel, A

    2000-01-01

    The primary objectives of this project were to evaluate the performance of the SGI CXFS File System in a Storage Area Network (SAN) and compare/contrast it to the performance of a locally attached XFS file system on the same computer and storage subsystems. The University of Minnesota participants were asked to verify that the performance of the SAN/CXFS configuration did not fall below 85% of the performance of the XFS local configuration. There were two basic hardware test configurations constructed from the following equipment: Two Onyx 2 computer systems each with two Qlogic-based Fibre Channel/XIO Host Bus Adapter (HBA); Onemore » 8-Port Brocade Silkworm 2400 Fibre Channel Switch; and Four Ciprico RF7000 RAID Disk Arrays populated Seagate Barracuda 50GB disk drives. The Operating System on each of the ONYX 2 computer systems was IRIX 6.5.6. The first hardware configuration consisted of directly connecting the Ciprico arrays to the Qlogic controllers without the Brocade switch. The purpose for this configuration was to establish baseline performance data on the Qlogic controllers / Ciprico disk raw subsystem. This baseline performance data would then be used to demonstrate any performance differences arising from the addition of the Brocade Fibre Channel Switch. Furthermore, the performance of the Qlogic controllers could be compared to that of the older, Adaptec-based XIO dual-channel Fibre Channel adapters previously used on these systems. It should be noted that only raw device tests were performed on this configuration. No file system testing was performed on this configuration. The second hardware configuration introduced the Brocade Fibre Channel Switch. Two FC ports from each of the ONYX2 computer systems were attached to four ports of the switch and the four Ciprico arrays were attached to the remaining four. Raw disk subsystem tests were performed on the SAN configuration in order to demonstrate the performance differences between the direct-connect and the switched configurations. After this testing was completed, the Ciprico arrays were formatted with an XFS file system and performance numbers were gathered to establish a File System Performance Baseline. Finally, the disks were formatted with CXFS and further tests were run to demonstrate the performance of the CXFS file system. A summary of the results of these tests is given.« less

  9. 40 CFR 600.207-08 - Calculation and use of vehicle-specific 5-cycle-based fuel economy values for vehicle...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... (i) Calculate the 5-cycle city and highway fuel economy values from the tests performed using gasoline or diesel test fuel. (ii)(A) Calculate the 5-cycle city and highway fuel economy values from the tests performed using alcohol or natural gas test fuel, if 5-cycle testing has been performed. Otherwise...

  10. Largo hot water system long range thermal performance test report, addendum

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The test procedure used and the test results obtained during the long range thermal performance tests of the LARGO Solar Hot Water System under natural environmental conditions are presented. Objectives of these tests were to determine the amount of energy collected, the amount of power required for system operation, system efficiency, temperature distribution, and system performance degradation.

  11. 40 CFR 60.93 - Test methods and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Test methods and procedures. 60.93... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Hot Mix Asphalt Facilities § 60.93 Test methods and procedures. (a) In conducting the performance tests required in § 60.8...

  12. Astronaut Scott Carpenter tests balance mechanism performance

    NASA Technical Reports Server (NTRS)

    1961-01-01

    Astronaut M. Scott Carpenter's balance mechanism performance is tested by his walking on a narrow board in his bare feet. He is performing this test at the School of Aviation Medicine, Pensicola, Florida (04570); Carpenter walks a straight line by putting one foot directly in front of the other to test his balance (04571).

  13. Using Multilevel Analysis to Monitor Test Performance across Administrations. Research Report. ETS RR-14-29

    ERIC Educational Resources Information Center

    Wei, Youhua; Qu, Yanxuan

    2014-01-01

    For a testing program with frequent administrations, it is important to understand and monitor the stability and fluctuation of test performance across administrations. Different methods have been proposed for this purpose. This study explored the potential of using multilevel analysis to understand and monitor examinees' test performance across…

  14. 42 CFR 84.103 - Man tests; performance requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Man tests; performance requirements. 84.103 Section...-Contained Breathing Apparatus § 84.103 Man tests; performance requirements. (a) The apparatus shall satisfy... is 24 ±6 °C. (75 ±10 °F.), the maximum temperature of inspired air recorded during man tests shall...

  15. 42 CFR 84.103 - Man tests; performance requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Man tests; performance requirements. 84.103 Section...-Contained Breathing Apparatus § 84.103 Man tests; performance requirements. (a) The apparatus shall satisfy... is 24 ±6 °C. (75 ±10 °F.), the maximum temperature of inspired air recorded during man tests shall...

  16. 42 CFR 84.103 - Man tests; performance requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Man tests; performance requirements. 84.103 Section...-Contained Breathing Apparatus § 84.103 Man tests; performance requirements. (a) The apparatus shall satisfy... is 24 ±6 °C. (75 ±10 °F.), the maximum temperature of inspired air recorded during man tests shall...

  17. Laboratory and clinical evaluation of on-site urine drug testing.

    PubMed

    Beck, Olof; Carlsson, Sten; Tusic, Marinela; Olsson, Robert; Franzen, Lisa; Hulten, Peter

    2014-11-01

    Products for on-site urine drug testing offer the possibility to perform screening for drugs of abuse directly at the point-of-care. This is a well-established routine in emergency and dependency clinics but further evaluation of performance is needed due to inherent limitations with the available products. Urine drug testing by an on-site product was compared with routine laboratory methods. First, on-site testing was performed at the laboratory in addition to the routine method. Second, the on-site testing was performed at a dependency clinic and urine samples were subsequently sent to the laboratory for additional analytical investigation. The on-site testing products did not perform with assigned cut-off levels. The subjective reading between the presence of a spot (i.e. negative test result) being present or no spot (positive result) was difficult in 3.2% of the cases, and occurred for all parameters. The tests performed more accurately in drug negative samples (specificity 96%) but less accurately for detecting positives (sensitivity 79%). Of all incorrect results by the on-site test the proportion of false negatives was 42%. The overall agreement between on-site and laboratory testing was 95% in the laboratory study and 98% in the clinical study. Although a high degree of agreement was observed between on-site and routine laboratory urine drug testing, the performance of on-site testing was not acceptable due to significant number of false negative results. The limited sensitivity of on-site testing compared to laboratory testing reduces the applicability of these tests.

  18. Pitting and Bending Fatigue Evaluations of a New Case-Carburized Gear Steel

    NASA Technical Reports Server (NTRS)

    Krantz, Timothy; Tufts, Brian

    2007-01-01

    The power density of a gearbox is an important consideration for many applications and is especially important for gearboxes used on aircraft. One approach to improving power density of gearing is to improve the steel properties by design of the alloy. The alloy tested in this work was designed to be case-carburized with surface hardness of Rockwell C66 after hardening. Test gear performance was evaluated using surface fatigue tests and single-tooth bending fatigue tests. The performance of gears made from the new alloy was compared to the performance of gears made from two alloys currently used for aviation gearing. The new alloy exhibited significantly better performance in surface fatigue testing, demonstrating the value of the improved properties in the case layer. However, the alloy exhibited lesser performance in single-tooth bending fatigue testing. The fracture toughness of the tested gears was insufficient for use in aircraft applications as judged by the behavior exhibited during the single tooth bending tests. This study quantified the performance of the new alloy and has provided guidance for the design and development of next generation gear steels.

  19. Test of Hydrogen-Oxygen PEM Fuel Cell Stack at NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Bents, David J.; Scullin, Vincent J.; Chang, Bei-Jiann; Johnson, Donald W.; Garcia, Christopher P.; Jakupca, Ian J.

    2003-01-01

    This paper describes performance characterization tests of a 64 cell hydrogen oxygen PEM fuel cell stack at NASA Glenn Research Center in February 2003. The tests were part of NASA's ongoing effort to develop a regenerative fuel cell for aerospace energy storage applications. The purpose of the tests was to verify capability of this stack to operate within a regenerative fuel cell, and to compare performance with earlier test results recorded by the stack developer. Test results obtained include polarization performance of the stack at 50 and 100 psig system pressure, and a steady state endurance run at 100 psig. A maximum power output of 4.8 kWe was observed during polarization runs, and the stack sustained a steady power output of 4.0 kWe during the endurance run. The performance data obtained from these tests compare reasonably close to the stack developer's results although some additional spread between best to worst performing cell voltages was observed. Throughout the tests, the stack demonstrated the consistent performance and repeatable behavior required for regenerative fuel cell operation.

  20. Collaborative Testing Improves Performance but Not Content Retention in a Large-Enrollment Introductory Biology Class

    PubMed Central

    Leight, Hayley; Saunders, Cheston; Calkins, Robin; Withers, Michelle

    2012-01-01

    Collaborative testing has been shown to improve performance but not always content retention. In this study, we investigated whether collaborative testing could improve both performance and content retention in a large, introductory biology course. Students were semirandomly divided into two groups based on their performances on exam 1. Each group contained equal numbers of students scoring in each grade category (“A”–“F”) on exam 1. All students completed each of the four exams of the semester as individuals. For exam 2, one group took the exam a second time in small groups immediately following the individually administered test. The other group followed this same format for exam 3. Individual and group exam scores were compared to determine differences in performance. All but exam 1 contained a subset of cumulative questions from the previous exam. Performances on the cumulative questions for exams 3 and 4 were compared for the two groups to determine whether there were significant differences in content retention. Even though group test scores were significantly higher than individual test scores, students who participated in collaborative testing performed no differently on cumulative questions than students who took the previous exam as individuals. PMID:23222835

  1. The Effects of Binge Drinking on College Students’ Next-Day Academic Test-Taking Performance and Mood State

    PubMed Central

    Howland, Jonathan; Rohsenow, Damaris J; Greece, Jacey A; Littlefield, Caroline A; Almeida, Alissa; Heeren, Timothy; Winter, Michael; Bliss, Caleb A.; Hunt, Sarah; Hermos, John

    2010-01-01

    Aim To assess the effects of binge drinking on students’ next-day academic test-taking performance. Design A placebo-controlled cross-over design with randomly assigned order of conditions. Participants were randomized to either alcoholic beverage (mean =.12 g% breath alcohol concentration [BrAC]) or placebo on the first night and then received the other beverage a week later. The next day, participants were assessed on test-taking, neurocognitive performance and mood state. Participants 193 college students (≥ 21 years) recruited from greater Boston. Setting The trial was conducted at the General Clinical Research Center at the Boston Medical Center. Measurements The Graduate Record Exams © (GREs) and a quiz on a lecture presented the previous day measured test-taking performance; the Neurobehavioral Evaluation System (NES3) and the Psychomotor Vigilance Test (PVT) measured neurocognitive performance; and, the Profile of Mood States (POMS) measured mood. Findings Test-taking performance was not affected the morning after alcohol administration, but mood state and attention/reaction time were. Conclusion Drinking to a level of .12 g% BrAC does not affect next-day test-taking performance, but does affect some neurocognitive measures and mood state. PMID:20403018

  2. Effect of added mass on treadmill performance and pulmonary function.

    PubMed

    Walker, Rachel E; Swain, David P; Ringleb, Stacie I; Colberg, Sheri R

    2015-04-01

    Military personnel engage in strenuous physical activity and load carriage. This study evaluated the role of body mass and of added mass on aerobic performance (uphill treadmill exercise) and pulmonary function. Performance on a traditional unloaded run test (4.8 km) was compared with performance on loaded tasks. Subjects performed an outdoor 4.8-km run and 4 maximal treadmill tests wearing loads of 0, 10, 20, and 30 kg. Subjects' pulmonary function (forced expired volume in 1 second [FEV1], forced vital capacity [FVC], and maximal voluntary ventilation [MVV]) was tested with each load, and peak values of heart rate, oxygen consumption ((Equation is included in full-text article.)), ventilation (VE), and respiratory exchange ratio (RER) were measured during each treadmill test. Performance on the 4.8-km run was correlated with treadmill performance, measured as time to exhaustion (TTE), with the strength of the correlation decreasing with load (r = 0.87 for 0 kg to 0.76 for 30 kg). Body mass was not correlated with TTE, other than among men with the 30-kg load (r = 0.48). During treadmill exercise, all peak responses other than RER decreased with load. Pulmonary function measures (FEV1, FVC, and MVV) decreased with load. Body mass was poorly correlated with treadmill performance, but added mass decreased performance. The decreased performance may be in part because of decreased pulmonary function. Unloaded 4.8-km run performance was correlated to unloaded uphill treadmill performance, but less so as load increased. Therefore, traditional run tests may not be an effective means of evaluating aerobic performance for military field operations.

  3. Evaluating Maintenance Performance: The Development of Graphic Symbolic Substitutes for Criterion Referenced Job Task Performance Tests for Electronic Maintenance. Final Report.

    ERIC Educational Resources Information Center

    Shriver, Edgar L.; Foley, John P., Jr.

    A battery of criterion referenced Job Task Performance Tests (JTPT) was developed because paper and pencil tests of job knowledge and electronic theory had very poor criterion-related or empirical validity with respect to the ability of electronic maintenance men to perform their job. Although the original JTPT required the use of actual…

  4. Papanicolaou Testing by Physicians in Manitoba: Who Does Them?

    PubMed Central

    Cohen, Marsha M.; Hammarstrand, Karen M.

    1989-01-01

    Pap testing is one of the few effective preventive health practices available to primary care physicians. Yet we know little about how well this procedure is being done. Using data from the province of Manitoba's universal health insurance plan for the years 1976, 1978 and 1982, we determined the proportion of all Pap tests of women over 25 years of age performed by the various physician specialties; the percentage of physicians in each specialty who performed tests; and the mean number of tests per specialty group. We also determined the mean number of tests by age and training of the physician. The number of physicians performing Pap tests increased from 749 in 1976 to 780 in 1982. About 2% of Pap tests performed in the province were done by internists, 5% by general surgeons, about 33% by obstetrician/gynecologists, 40% by urban general practitioners, and 22% by rural general practitioners. Other physicians accounted for less than 0.2% of all tests. The mean number of Pap tests performed increased with increasing physician age up to age 60 and declined thereafter. Manitoba-trained physicians performed the highest rate of Pap testing, and this pattern was maintained over time. In 1982, only 22% of internists, 29% of general surgeons, and 78% of family physicians/general practitioners were performing tests. These results raise the question of why a significant number of physicians are not carrying out this effective preventive health practice. PMID:21248879

  5. 40 CFR 60.53b - Standards for municipal waste combustor operating practices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... for the purpose of evaluating system performance, testing new technology or control technologies... evaluating system performance, testing new technology or control technologies, diagnostic testing, or related... (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of...

  6. Uniform peanut performance test 2017

    USDA-ARS?s Scientific Manuscript database

    The Uniform Peanut Performance Tests (UPPT) are designed to evaluate the commercial potential of advanced breeding peanut lines not formally released. The tests are performed in ten locations across the peanut production belt. In this study, 2 controls and 14 entries were evaluated at 8 locations....

  7. 49 CFR 238.103 - Fire safety.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... September 9, 2002, shall meet the test performance criteria for flammability and smoke emission..., refurbishment, or overhaul of the car or cab, shall meet the test performance criteria for flammability and... of tests of material conducted in accordance with the standards and performance criteria for...

  8. Cold startup and low temperature performance of the Brayton cycle electrical subsystem

    NASA Technical Reports Server (NTRS)

    Vrancik, J. E.; Bainbridge, R. C.

    1971-01-01

    Cold performance tests and startup tests were conducted on the Brayton-cycle inverter, motor-driven pump, dc supply, speed control with parasitic load resistor and the Brayton control system. These tests were performed with the components in a vacuum and mounted on coldplates. A temperature range of ?25 to -50 C was used for the tests. No failures occurred, and component performance gave no indication that there would be any problem with the safe operation of the Brayton power generating system.

  9. Dynamic Response of X-37 Hot Structure Control Surfaces Exposed to Controlled Reverberant Acoustic Excitation

    NASA Technical Reports Server (NTRS)

    Grosveld, Ferdinand W.; Rizzi, Stephen A.; Rice, Chad E.

    2004-01-01

    This document represents a compilation of three informal reports from reverberant acoustic tests performed on X-37 hot structure control surfaces in the NASA Langley Research Center Structural Acoustics Loads and Transmission (SALT) facility. The first test was performed on a carbon-silicone carbide flaperon subcomponent on February 24, 2004. The second test was performed on a carbon-carbon ruddervator subcomponent on May 27, 2004. The third test was performed on a carbon-carbon flaperon subcomponent on June 30, 2004.

  10. Relationships between field performance tests in high-level soccer players.

    PubMed

    Ingebrigtsen, Jørgen; Brochmann, Marit; Castagna, Carlo; Bradley, Paul S; Ade, Jack; Krustrup, Peter; Holtermann, Andreas

    2014-04-01

    To reduce athlete testing time, the aim of this study was to investigate the relationship between the Yo-Yo intermittent recovery test levels 1 (IR1) and 2 (IR2) performances, maximal sprinting speed (10, 20, and 35 m), repeated sprint ability (RSA; 7 × 35 m), and submaximal heart rates (HRs) after 2 and 4 minutes of the Yo-Yo IR tests by testing 57 high-level soccer players. All players played regularly in one of 3 highest levels of Norwegian soccer and were tested during 3 sessions on 3 consecutive days. Large correlations were observed between Yo-Yo IR1 and IR2 test performances (r = 0.753, p ≤ 0.05). Small and moderate correlations were found between 20- and 35-m sprinting speed and Yo-Yo IR1 performance (r = -0.289 and -0.321, respectively, p ≤ 0.05), whereas 35-m sprinting speed correlated moderately to Yo-Yo IR2 performance (r = -0.371, p ≤ 0.05). Repeated sprint ability at 10, 20, and 35 m all showed moderate to large correlations to Yo-Yo IR1 performance (r = -0.337 to -0.573, p ≤ 0.05). Repeated sprint ability at 20 m (r = -0.348, p ≤ 0.05) and 35 m (r = -0.552, p ≤ 0.01) correlated moderately and largely to Yo-Yo IR2 performance. In addition, moderate and large correlations were found between submaximal Yo-Yo IR1 HRs after 2 (r = -0.483, p ≤ 0.01) and 4 minutes (r = -0.655, p ≤ 0.01) and Yo-Yo IR1 performance, and 2 minutes Yo-Yo IR2 HR and Yo-Yo IR2 performance (r = -0.530, p ≤ 0.01). Intraclass correlation measures of submaximal HR after 2 and 4 minutes of Yo-Yo IR1 test and after 2 minutes of the Yo-Yo IR2 were 0.92 (coefficient of variation [CV] = 4.1%, n = 33), 0.93 (CV = 3.8%, n = 33), and 0.72 (CV = 2.9%, n = 10). Adjusted ordinary least square (OLS) regressions revealed associations (p ≤ 0.05) between sprint speed at 20 and 35 m and Yo-Yo IR1 test performance, but only between 35 m and IR2 test performance (p ≤ 0.05). Further, OLS showed that RSA at 35 m was related to both levels of the Yo-Yo IR test (p ≤ 0.01), and that submaximal HRs after 2 and 4 minutes were independently associated with Yo-Yo IR1 and IR2 performances (p ≤ 0.01). In conclusion, Yo-Yo IR1 and 2 test performances, as well as sprint and RSA performances, correlated very largely, and it may therefore be considered using only one of the Yo-Yo tests and a RSA test, in a general soccer-specific field test protocol. The submaximal HR measures during Yo-Yo tests are reproducible and may be used for frequent, time-efficient, and nonexhaustive testing of intermittent exercise capacity of high-level soccer players.

  11. Design and Development of E3 Antenna Container,

    DTIC Science & Technology

    1985-09-03

    reinforced with square tubing. The walls and ceiling shall be insulated with expanded polystyrene . TEST LOCATION - This test will be performed at the...ceiling shall be insulated with expanded polystyrene . TEST LOCATION - This test will be performed at the Edgewater Machine & Fabricator’s facility...insulated with expanded polystyrene . TEST LOCATION - This test will be performed at the Edgewater Machine & Fabricator’s facility located at 200 N

  12. Effects of Seated Postural Stability and Trunk and Upper Extremity Strength on Performance during Manual Wheelchair Propulsion Tests in Individuals with Spinal Cord Injury: An Exploratory Study.

    PubMed

    Gagnon, Dany H; Roy, Audrey; Gabison, Sharon; Duclos, Cyril; Verrier, Molly C; Nadeau, Sylvie

    2016-01-01

    Objectives. To quantify the association between performance-based manual wheelchair propulsion tests (20 m propulsion test, slalom test, and 6 min propulsion test), trunk and upper extremity (U/E) strength, and seated reaching capability and to establish which ones of these variables best predict performance at these tests. Methods. 15 individuals with a spinal cord injury (SCI) performed the three wheelchair propulsion tests prior to discharge from inpatient SCI rehabilitation. Trunk and U/E strength and seated reaching capability with unilateral hand support were also measured. Bivariate correlation and multiple linear regression analyses allowed determining the best determinants and predictors, respectively. Results. The performance at the three tests was moderately or strongly correlated with anterior and lateral flexion trunk strength, anterior seated reaching distance, and the shoulder, elbow, and handgrip strength measures. Shoulder adductor strength-weakest side explained 53% of the variance on the 20-meter propulsion test-maximum velocity. Shoulder adductor strength-strongest side and forward seated reaching distance explained 71% of the variance on the slalom test. Handgrip strength explained 52% of the variance on the 6-minute propulsion test. Conclusion. Performance at the manual wheelchair propulsion tests is explained by a combination of factors that should be considered in rehabilitation.

  13. Upgraded demonstration vehicle task report

    NASA Technical Reports Server (NTRS)

    Bryant, J.; Hardy, K.; Livingston, R.; Sandberg, J.

    1981-01-01

    Vehicle/battery performance capabilities and interface problems that occurred when upgraded developmental batteries were integrated with upgraded versions of comercially available electric vehicles were investigated. Developmental batteries used included nickel zinc batteries, a nickel iron battery, and an improved lead acid battery. Testing of the electric vehicles and upgraded batteries was performed in the complete vehicle system environment to characterize performance and identify problems unique to the vehicle/battery system. Constant speed tests and driving schedule range tests were performed on a chassis dynamometer. The results from these tests of the upgraded batteries and vehicles were compared to performance capabilities for the same vehicles equipped with standard batteries.

  14. Specific physiological and biomechanical performance in elite, sub-elite and in non-elite male team handball players.

    PubMed

    Wagner, Herbert; Fuchs, Philip X; von Duvillard, Serge P

    2018-01-01

    Team handball is a dynamic sport game that is played professionally in numerous countries. However, knowledge about training and competition is based mostly on practical experience due to limited scientific studies. Consequently, the aims of our study were to compare specific physiological and biomechanical performance in elite, sub-elite and in non-elite male team handball players. Thirty-six elite, sub-elite and non-elite male team handball players performed a game based performance test, upper-body and lower-body strength tests, 30-m sprint test, counter movement jump test and an incremental treadmill running test. Significant differences (P<0.05) were found for the peak oxygen uptake, heart rate, offense and defense time, jump height and ball velocity during the jump throw in the game based performance test, maximal oxygen uptake in the incremental treadmill running test as well as in maximal leg strength and leg explosive strength in the isometric strength test. Elite male players have an enhanced specific agility, a better throwing performance, a higher team handball specific oxygen uptake and higher leg strength compared to sub-elite and non-elite players. Based on these results we recommend that training in team handball should focus on game based training methods to improve performance in specific agility, endurance and technique.

  15. Sensitivity to change of the field-based Wheelchair Mobility Performance Test in wheelchair basketball.

    PubMed

    de Witte, Annemarie M H; Sjaarda, Fleur; Helleman, Jochem; Berger, Monique A M; van der Woude, Lucas H V; Hoozemans, Marco J M

    2018-06-15

    The Wheelchair Mobility Performance (WMP) test is a reliable and valid measure to assess mobility performance in wheelchair basketball. The aim of this study was to examine the sensitivity to change of the WMP test by manipulating wheelchair configurations. Sixteen wheelchair basketball players performed the WMP test 3 times in their own wheelchair: (i) without adjustments ("control condition"); (ii) with 10 kg additional mass ("weighted condition"); and (iii) with 50% reduced tyre pressure ("tyre condition"). The outcome measure was time (s). If paired t-tests were significant (p <0.05) and differences between conditions were larger than the standard error of measurement, the effect sizes (ES) were used to evaluate the sensitivity to change. ES values ≥0.2 were regarded as sensitive to change. The overall performance times for the manipulations were significantly higher than the control condition, with mean differences of 4.40 s (weight - control, ES = 0.44) and 2.81 s (tyre - control, ES = 0.27). The overall performance time on the WMP test was judged as sensitive to change. For 8 of the 15 separate tasks on the WMP test, the tasks were judged as sensitive to change for at least one of the manipulations. The WMP test can detect change in mobility performance when wheelchair configurations are manipulated.

  16. Solid rocket booster performance evaluation model. Volume 1: Engineering description

    NASA Technical Reports Server (NTRS)

    1974-01-01

    The space shuttle solid rocket booster performance evaluation model (SRB-II) is made up of analytical and functional simulation techniques linked together so that a single pass through the model will predict the performance of the propulsion elements of a space shuttle solid rocket booster. The available options allow the user to predict static test performance, predict nominal and off nominal flight performance, and reconstruct actual flight and static test performance. Options selected by the user are dependent on the data available. These can include data derived from theoretical analysis, small scale motor test data, large motor test data and motor configuration data. The user has several options for output format that include print, cards, tape and plots. Output includes all major performance parameters (Isp, thrust, flowrate, mass accounting and operating pressures) as a function of time as well as calculated single point performance data. The engineering description of SRB-II discusses the engineering and programming fundamentals used, the function of each module, and the limitations of each module.

  17. Mindfulness, anxiety, and high-stakes mathematics performance in the laboratory and classroom.

    PubMed

    Bellinger, David B; DeCaro, Marci S; Ralston, Patricia A S

    2015-12-01

    Mindfulness enhances emotion regulation and cognitive performance. A mindful approach may be especially beneficial in high-stakes academic testing environments, in which anxious thoughts disrupt cognitive control. The current studies examined whether mindfulness improves the emotional response to anxiety-producing testing situations, freeing working memory resources, and improving performance. In Study 1, we examined performance in a high-pressure laboratory setting. Mindfulness indirectly benefited math performance by reducing the experience of state anxiety. This benefit occurred selectively for problems that required greater working memory resources. Study 2 extended these findings to a calculus course taken by undergraduate engineering majors. Mindfulness indirectly benefited students' performance on high-stakes quizzes and exams by reducing their cognitive test anxiety. Mindfulness did not impact performance on lower-stakes homework assignments. These findings reveal an important mechanism by which mindfulness benefits academic performance, and suggest that mindfulness may help attenuate the negative effects of test anxiety. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Selection of performance-tested young bulls and indirect responses in commercial beef cattle herds on pasture and in feedlots.

    PubMed

    Raidan, Fernanda S S; Santos, Dalinne C C; Moraes, Mariana M; Araújo, Andresa E M; Ventura, Henrique T; Bergmann, José A G; Turra, Eduardo M; Toral, Fabio L B

    2016-11-09

    Central testing is used to select young bulls which are likely to contribute to increased net income of the commercial beef cattle herd. We present genetic parameters for growth and reproductive traits on performance-tested young bulls and commercial animals that are raised on pasture and in feedlots. Records on young bulls and heifers in performance tests or commercial herds were used. Genetic parameters for growth and reproductive traits were estimated. Correlated responses for commercial animals when selection was applied on performance-tested young bulls were computed. The 90% highest posterior density (HPD90) intervals for heritabilities of final weight (FW), average daily gain (ADG) and scrotal circumference (SC) ranged from 0.41 to 0.49, 0.23 to 0.30 and 0.47 to 0.57, respectively, for performance-tested young bulls on pasture, from 0.45 to 0.60, 0.20 to 0.32 and 0.56 to 0.70, respectively, for performance-tested young bulls in feedlots, from 0.29 to 0.33, 0.14 to 0.18 and 0.35 to 0.45, respectively, for commercial animals on pasture, and from 0.24 to 0.44, 0.13 to 0.24 and 0.35 to 0.57 respectively, for commercial animals in feedlots. The HPD90 intervals for genetic correlations of FW, ADG and SC in performance-tested young bulls on pasture (feedlots) with FW, ADG and SC in commercial animals on pasture (feedlots) ranged from 0.86 to 0.96 (0.83 to 0.94), 0.78 to 0.90 (0.40 to 0.79) and from 0.92 to 0.97 (0.50 to 0.83), respectively. Age at first calving was genetically related to ADG (HPD90 interval = -0.48 to -0.06) and SC (HPD90 interval = -0.41 to -0.05) for performance-tested young bulls on pasture, however it was not related to ADG (HPD90 interval = -0.29 to 0.10) and SC (HPD90 interval = -0.35 to 0.13) for performance-tested young bulls in feedlots. Heritabilities for growth and SC are higher for performance-tested young bulls than for commercial animals. Evaluating and selecting for increased growth and SC on performance-tested young bulls is efficient to improve growth, SC and age at first calving in commercial animals. Evaluating and selecting performance-tested young bulls is more efficient for young bulls on pasture than in feedlots.

  19. Fitness for duty: A 3 minute version of the Psychomotor Vigilance Test predicts fatigue related declines in luggage screening performance

    PubMed Central

    Basner, Mathias; Rubinstein, Joshua

    2011-01-01

    Objective To evaluate the ability of a 3-min Psychomotor Vigilance Test (PVT) to predict fatigue related performance decrements on a simulated luggage screening task (SLST). Methods Thirty-six healthy non-professional subjects (mean age 30.8 years, 20 female) participated in a 4 day laboratory protocol including a 34 hour period of total sleep deprivation with PVT and SLST testing every 2 hours. Results Eleven and 20 lapses (355 ms threshold) on the PVT optimally divided SLST performance into high, medium, and low performance bouts with significantly decreasing threat detection performance A′. Assignment to the different SLST performance groups replicated homeostatic and circadian patterns during total sleep deprivation. Conclusions The 3 min PVT was able to predict performance on a simulated luggage screening task. Fitness-for-duty feasibility should now be tested in professional screeners and operational environments. PMID:21912278

  20. Fitness for duty: a 3-minute version of the Psychomotor Vigilance Test predicts fatigue-related declines in luggage-screening performance.

    PubMed

    Basner, Mathias; Rubinstein, Joshua

    2011-10-01

    To evaluate the ability of a 3-minute Psychomotor Vigilance Test (PVT) to predict fatigue-related performance decrements on a simulated luggage-screening task (SLST). Thirty-six healthy nonprofessional subjects (mean age = 30.8 years, 20 women) participated in a 4-day laboratory protocol including a 34-hour period of total sleep deprivation with PVT and SLST testing every 2 hours. Eleven and 20 lapses (355-ms threshold) on the PVT optimally divided SLST performance into high-, medium-, and low-performance bouts with significantly decreasing threat detection performance A'. Assignment to the different SLST performance groups replicated homeostatic and circadian patterns during total sleep deprivation. The 3-minute PVT was able to predict performance on a simulated luggage-screening task. Fitness-for-duty feasibility should now be tested in professional screeners and operational environments.

  1. Vehicle test report: Electric Vehicle Associates electric conversion of an AMC Pacer

    NASA Technical Reports Server (NTRS)

    Price, T. W.; Wirth, V. A., Jr.; Pampa, M. F.

    1981-01-01

    The change of pace, an electric vehicle was tested. These tests were performed to characterize certain parameters of the electric vehicle pacer and to provide baseline data that can be used for the comparison of improved batteries that may be incorporated into the vehicle at a later time. The vehicle tests were concentrated on the electrical drive subsystem, the batteries, controller and motor. Coastdowns to characterize the road load, and range evaluations for both cyclic and constant speed conditions were performed. The vehicle's performance was evaluated by comparing its constant speed range performance with described vehicles. It is found that the pacer performance is approximately equal to the majority of the vehicles tested in the 1977 assessment.

  2. Diagnosing and alleviating the impact of performance pressure on mathematical problem solving.

    PubMed

    DeCaro, Marci S; Rotar, Kristin E; Kendra, Matthew S; Beilock, Sian L

    2010-08-01

    High-pressure academic testing situations can lead people to perform below their actual ability levels by co-opting working memory (WM) resources needed for the task at hand (Beilock, 2008). In the current work we examine how performance pressure impacts WM and design an intervention to alleviate pressure's negative impact. Specifically, we explore the hypothesis that high-pressure situations trigger distracting thoughts and worries that rely heavily on verbal WM. Individuals performed verbally based and spatially based mathematics problems in a low-pressure or high-pressure testing situation. Results demonstrated that performance on problems that rely heavily on verbal WM resources was less accurate under high-pressure than under low-pressure tests. Performance on spatially based problems that do not rely heavily on verbal WM was not affected by pressure. Moreover, the more people reported worrying during test performance, the worse they performed on the verbally based (but not spatially based) maths problems. Asking some individuals to focus on the problem steps by talking aloud helped to keep pressure-induced worries at bay and eliminated pressure's negative impact on performance.

  3. Wind Tunnel and Hover Performance Test Results for Multicopter UAS Vehicles

    NASA Technical Reports Server (NTRS)

    Russell, Carl R.; Jung, Jaewoo; Willink, Gina; Glasner, Brett

    2016-01-01

    There is currently a lack of published data for the performance of multicopter unmanned aircraft system (UAS) vehicles, such as quadcopters and octocopters, often referred to collectively as drones. With the rapidly increasing popularity of multicopter UAS, there is interest in better characterizing the performance of this type of aircraft. By studying the performance of currently available vehicles, it will be possible to develop models for vehicles at this scale that can accurately predict performance and model trajectories. This paper describes a wind tunnel test that was recently performed in the U.S. Army's 7- by 10-ft Wind Tunnel at NASA Ames Research Center. During this wind tunnel entry, five multicopter UAS vehicles were tested to determine forces and moments as well as electrical power as a function of wind speed, rotor speed, and vehicle attitude. The test is described here in detail, and a selection of the key results from the test is presented.

  4. A Finite Rate Chemical Analysis of Nitric Oxide Flow Contamination Effects on Scramjet Performance

    NASA Technical Reports Server (NTRS)

    Cabell, Karen F.; Rock, Kenneth E.

    2003-01-01

    The level of nitric oxide contamination in the test gas of the Langley Research Center Arc-Heated Scramjet Test Facility and the effect of the contamination on scramjet test engine performance were investigated analytically. A finite rate chemical analysis was performed to determine the levels of nitric oxide produced in the facility at conditions corresponding to Mach 6 to 8 flight simulations. Results indicate that nitric oxide levels range from one to three mole percent, corroborating previously obtained measurements. A three-stream combustor code with finite rate chemistry was used to investigate the effects of nitric oxide on scramjet performance. Results indicate that nitric oxide in the test gas causes a small increase in heat release and thrust performance for the test conditions investigated. However, a rate constant uncertainty analysis suggests that the effect of nitric oxide ranges from no net effect, to an increase of about 10 percent in thrust performance.

  5. Exploring the motivation jungle: predicting performance on a novel task by investigating constructs from different motivation perspectives in tandem.

    PubMed

    Van Nuland, Hanneke J C; Dusseldorp, Elise; Martens, Rob L; Boekaerts, Monique

    2010-08-01

    Different theoretical viewpoints on motivation make it hard to decide which model has the best potential to provide valid predictions on classroom performance. This study was designed to explore motivation constructs derived from different motivation perspectives that predict performance on a novel task best. Motivation constructs from self-determination theory, self-regulation theory, and achievement goal theory were investigated in tandem. Performance was measured by systematicity (i.e. how systematically students worked on a problem-solving task) and test score (i.e. score on a multiple-choice test). Hierarchical regression analyses on data from 259 secondary school students showed a quadratic relation between a performance avoidance orientation and both performance outcomes, indicating that extreme high and low performance avoidance resulted in the lowest performance. Furthermore, two three-way interaction effects were found. Intrinsic motivation seemed to play a key role in test score and systematicity performance, provided that effort regulation and metacognitive skills were both high. Results indicate that intrinsic motivation in itself is not enough to attain a good performance. Instead, a moderate score on performance avoidance, together with the ability to remain motivated and effectively regulate and control task behavior, is needed to attain a good performance. High time management skills also contributed to higher test score and systematicity performance and a low performance approach orientation contributed to higher systematicity performance. We concluded that self-regulatory skills should be trained in order to have intrinsically motivated students perform well on novel tasks in the classroom.

  6. Memory-For-Designs Test: Comparison of Performance of Young and Old Adults.

    ERIC Educational Resources Information Center

    Dustman, Robert E.; Beck, Edward C.

    1980-01-01

    No significant decline in performance occurred before age 50. Decline in Memory-For-Designs Test performance after age 60 is sufficient to suggest caution in the use of the test for evaluation of brain damage in the older patient. (Author)

  7. 40 CFR 60.2110 - What operating limits must I meet and by when?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... during the most recent performance test demonstrating compliance with all applicable emission limitations... most recent performance test demonstrating compliance with all applicable emission limitations. (2... drop across the wet scrubber measured during the most recent performance test demonstrating compliance...

  8. 40 CFR 60.2110 - What operating limits must I meet and by when?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... during the most recent performance test demonstrating compliance with all applicable emission limitations... most recent performance test demonstrating compliance with all applicable emission limitations. (2... drop across the wet scrubber measured during the most recent performance test demonstrating compliance...

  9. 40 CFR 60.2110 - What operating limits must I meet and by when?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... during the most recent performance test demonstrating compliance with all applicable emission limitations... most recent performance test demonstrating compliance with all applicable emission limitations. (2... drop across the wet scrubber measured during the most recent performance test demonstrating compliance...

  10. Plug cluster module demonstration

    NASA Technical Reports Server (NTRS)

    Rousar, D. C.

    1978-01-01

    The low pressure, film cooled rocket engine design concept developed during two previous ALRC programs was re-evaluated for application as a module for a plug cluster engine capable of performing space shuttle OTV missions. The nominal engine mixture ratio was 5.5 and the engine life requirements were 1200 thermal cycles and 10 hours total operating life. The program consisted of pretest analysis; engine tests, performed using residual components; and posttest analysis. The pretest analysis indicated that operation of the operation of the film cooled engine at O/F = 5.5 was feasible. During the engine tests, steady state wall temperature and performance measurement were obtained over a range of film cooling flow rates, and the durability of the engine was demonstrated by firing the test engine 1220 times at a nominal performance ranging from 430 - 432 seconds. The performance of the test engine was limited by film coolant sleeve damage which had occurred during previous testing. The post-test analyses indicated that the nominal performance level can be increased to 436 seconds.

  11. Hypersonic research engine project. Phase 2: Preliminary report on the performance of the HRE/AIM at Mach 6

    NASA Technical Reports Server (NTRS)

    Sun, Y. H.; Sainio, W. C.

    1975-01-01

    Test results of the Aerothermodynamic Integration Model are presented. A program was initiated to develop a hydrogen-fueled research-oriented scramjet for operation between Mach 3 and 8. The primary objectives were to investigate the internal aerothermodynamic characteristics of the engine, to provide realistic design parameters for future hypersonic engine development as well as to evaluate the ground test facility and testing techniques. The engine was tested at the NASA hypersonic tunnel facility with synthetic air at Mach 5, 6, and 7. The hydrogen fuel was heated up to 1500 R prior to injection to simulate a regeneratively cooled system. The engine and component performance at Mach 6 is reported. Inlet performance compared very well both with theory and with subscale model tests. Combustor efficiencies up to 95 percent were attained at an equivalence ratio of unity. Nozzle performance was lower than expected. The overall engine performance was computed using two different methods. The performance was also compared with test data from other sources.

  12. The Relationship of Laboratory Performance Ratings, Information Achievement and Pencil-Paper Performance Test Scores in College-Level Electricity.

    ERIC Educational Resources Information Center

    Francis, Charles E.

    In this study, a pencil paper performance test (PPPT) was developed and administered to an experimental group of 46 students and a control group of 48 students to determine: (1) the difference between laboratory performance and the successful completion of a laboratory course in electricity, (2) the relationship between laboratory performance as…

  13. Performance of the Primary Mirror Center-of-Curvature Optical Metrology System during Cryogenic Testing of the JWST Pathfinder Telescope

    NASA Technical Reports Server (NTRS)

    Hadaway, James B.; Wells, Conrad; Olczak, Gene; Waldman, Mark; Whitman, Tony; Cosentino, Joseph; Connolly, Mark; Chaney, David; Telfer, Randal

    2016-01-01

    The JWST primary mirror consists of 18 1.5 m hexagonal segments, each with 6-DoF and RoC adjustment. The telescope will be tested at its cryogenic operating temperature at Johnson Space Center. The testing will include center-of-curvature measurements of the PM, using the Center-of-Curvature Optical Assembly (COCOA) and the Absolute Distance Meter Assembly (ADMA). The performance of these metrology systems, including hardware, software, procedures, was assessed during two cryogenic tests at JSC, using the JWST Pathfinder telescope. This paper describes the test setup, the testing performed, and the resulting metrology system performance.

  14. Comparison of Orion Vision Navigation Sensor Performance from STS-134 and the Space Operations Simulation Center

    NASA Technical Reports Server (NTRS)

    Christian, John A.; Patangan, Mogi; Hinkel, Heather; Chevray, Keiko; Brazzel, Jack

    2012-01-01

    The Orion Multi-Purpose Crew Vehicle is a new spacecraft being designed by NASA and Lockheed Martin for future crewed exploration missions. The Vision Navigation Sensor is a Flash LIDAR that will be the primary relative navigation sensor for this vehicle. To obtain a better understanding of this sensor's performance, the Orion relative navigation team has performed both flight tests and ground tests. This paper summarizes and compares the performance results from the STS-134 flight test, called the Sensor Test for Orion RelNav Risk Mitigation (STORRM) Development Test Objective, and the ground tests at the Space Operations Simulation Center.

  15. Development of microcomputer-based mental acuity tests.

    PubMed

    Turnage, J J; Kennedy, R S; Smith, M G; Baltzley, D R; Lane, N E

    1992-10-01

    Recent disasters have focused attention on performance problems due to the use of alcohol and controlled substances in the workplace. Environmental stressors such as thermal extremes, mixed gases, noise, motion, and vibration also have adverse effects on human performance and operator efficiency. However, the lack of a standardized, sensitive, human performance assessment battery has probably delayed the systematic study of the deleterious effects of various toxic chemicals and drugs at home and in the workplace. The collective goal of the research reported here is the development of a menu of tests embedded in a coherent package of hardware and software that may be useful in repeated-measures studies of a broad range of agents that can degrade human performance. A menu of 40 tests from the Automated Performance Test System (APTS) is described, and the series of interlocking studies supporting its development is reviewed. The APTS tests, which run on several versions of laptop portables and desktop personal computers, have been shown to be stable, reliable, and factorially rich, and to have predictive validities with holistic measures of intelligence and simulator performances. In addition, sensitivity studies have been conducted in which performance changes due to stressors, agents, and treatments were demonstrated. We believe that tests like those described here have prospective use as an adjunct to urine testing for the screening for performance loss of individuals who are granted access to workplaces and stations that impact public safety.

  16. Development of microcomputer-based mental acuity tests

    NASA Technical Reports Server (NTRS)

    Turnage, J. J.; Kennedy, R. S.; Smith, M. G.; Baltzley, D. R.; Lane, N. E.

    1992-01-01

    Recent disasters have focused attention on performance problems due to the use of alcohol and controlled substances in the workplace. Environmental stressors such as thermal extremes, mixed gases, noise, motion, and vibration also have adverse effects on human performance and operator efficiency. However, the lack of a standardized, sensitive, human performance assessment battery has probably delayed the systematic study of the deleterious effects of various toxic chemicals and drugs at home and in the workplace. The collective goal of the research reported here is the development of a menu of tests embedded in a coherent package of hardware and software that may be useful in repeated-measures studies of a broad range of agents that can degrade human performance. A menu of 40 tests from the Automated Performance Test System (APTS) is described, and the series of interlocking studies supporting its development is reviewed. The APTS tests, which run on several versions of laptop portables and desktop personal computers, have been shown to be stable, reliable, and factorially rich, and to have predictive validities with holistic measures of intelligence and simulator performances. In addition, sensitivity studies have been conducted in which performance changes due to stressors, agents, and treatments were demonstrated. We believe that tests like those described here have prospective use as an adjunct to urine testing for the screening for performance loss of individuals who are granted access to workplaces and stations that impact public safety.

  17. DECIDE: a software for computer-assisted evaluation of diagnostic test performance.

    PubMed

    Chiecchio, A; Bo, A; Manzone, P; Giglioli, F

    1993-05-01

    The evaluation of the performance of clinical tests is a complex problem involving different steps and many statistical tools, not always structured in an organic and rational system. This paper presents a software which provides an organic system of statistical tools helping evaluation of clinical test performance. The program allows (a) the building and the organization of a working database, (b) the selection of the minimal set of tests with the maximum information content, (c) the search of the model best fitting the distribution of the test values, (d) the selection of optimal diagnostic cut-off value of the test for every positive/negative situation, (e) the evaluation of performance of the combinations of correlated and uncorrelated tests. The uncertainty associated with all the variables involved is evaluated. The program works in a MS-DOS environment with EGA or higher performing graphic card.

  18. Evaluation plan for space station network interface units

    NASA Technical Reports Server (NTRS)

    Weaver, Alfred C.

    1990-01-01

    Outlined here is a procedure for evaluating network interface units (NIUs) produced for the Space Station program. The procedures should be equally applicable to the data management system (DMS) testbed NIUs produced by Honeywell and IBM. The evaluation procedures are divided into four areas. Performance measurement tools are hardware and software that must be developed in order to evaluate NIU performance. Performance tests are a series of tests, each of which documents some specific characteristic of NIU and/or network performance. In general, these performance tests quantify the speed, capacity, latency, and reliability of message transmission under a wide variety of conditions. Functionality tests are a series of tests and code inspections that demonstrate the functionality of the particular subset of ISO protocols which have been implemented in a given NIU. Conformance tests are a series of tests which would expose whether or not selected features within the ISO protocols are present and interoperable.

  19. Long-term CF6 engine performance deterioration: Evaluation of engine S/N 451-380

    NASA Technical Reports Server (NTRS)

    Kramer, W. H.; Smith, J. J.

    1978-01-01

    The performance testing and analytical teardown of CF6-6D engine serial number 451-380 which was recently removed from a DC-10 aircraft is summarized. The investigative test program was conducted inbound prior to normal overhaul/refurbishment. The performance testing included an inbound test, a test following cleaning of the low pressure turbine airfoils, and a final test after leading edge rework and cleaning the stage one fan blades. The analytical teardown consisted of detailed disassembly inspection measurements and airfoil surface finish checks of the as-received deteriorated hardware. Aspects discussed include the analysis of the test cell performance data, a complete analytical teardown report with a detailed description of all observed hardware distress, and an analytical assessment of the performance loss (deterioration) relating measured hardware conditions to losses in both specific fuel comsumption and exhaust gas temperature.

  20. Long-term CF6 engine performance deterioration: Evaluation of engine S/N 451-479

    NASA Technical Reports Server (NTRS)

    Kramer, W. H.; Smith, J. J.

    1978-01-01

    The performance testing and analytical teardown of CF6-6D engine is summarized. This engine had completed its initial installation on DC-10 aircraft. The investigative test program was conducted inbound prior to normal overhaul/refurbishment. The performance testing included an inbound test, a test following cleaning of the low pressure turbine airfoils, and a final test after leading edge rework and cleaning the stage one fan blades. The analytical teardown consisted of detailed disassembly inspection measurements and airfoil surface finish checks of the as received deteriorated hardware. Included in this report is a detailed analysis of the test cell performance data, a complete analytical teardown report with a detailed description of all observed hardware distress, and an analytical assessment of the performance loss (deterioration) relating measured hardware conditions to losses in both SFC (specific fuel consumption) and EGT (exhaust gas temperature).

  1. Performance tests of a power-electronics converter for multi-megawatt wind turbines using a grid emulator

    NASA Astrophysics Data System (ADS)

    Rizqy Averous, Nurhan; Berthold, Anica; Schneider, Alexander; Schwimmbeck, Franz; Monti, Antonello; De Doncker, Rik W.

    2016-09-01

    A vast increase of wind turbines (WT) contribution in the modern electrical grids have led to the development of grid connection requirements. In contrast to the conventional test method, testing power-electronics converters for WT using a grid emulator at Center for Wind Power Drives (CWD) RWTH Aachen University offers more flexibility for conducting test scenarios. Further analysis on the performance of the device under test (DUT) is however required when testing with grid emulator since the characteristic of the grid emulator might influence the performance of the DUT. This paper focuses on the performance analysis of the DUT when tested using grid emulator. Beside the issue regarding the current harmonics, the performance during Fault Ride-Through (FRT) is discussed in detail. A power hardware in the loop setup is an attractive solution to conduct a comprehensive study on the interaction between the power-electronics converters and the electrical grids.

  2. Robust tracking control of a magnetically suspended rigid body

    NASA Technical Reports Server (NTRS)

    Lim, Kyong B.; Cox, David E.

    1994-01-01

    This study is an application of H-infinity and micro-synthesis for designing robust tracking controllers for the Large Angle Magnetic Suspension Test Facility. The modeling, design, analysis, simulation, and testing of a control law that guarantees tracking performance under external disturbances and model uncertainties is investigated. The type of uncertainties considered and the tracking performance metric used is discussed. This study demonstrates the tradeoff between tracking performance at low frequencies and robustness at high frequencies. Two sets of controllers were designed and tested. The first set emphasized performance over robustness, while the second set traded off performance for robustness. Comparisons of simulation and test results are also included. Current simulation and experimental results indicate that reasonably good robust tracking performance can be attained for this system using multivariable robust control approach.

  3. Test of acoustic tone source and propulsion performance of C8A Buffalo suppressor nozzle

    NASA Technical Reports Server (NTRS)

    Marrs, C. C.; Harkonen, D. L.; Okeefe, J. V.

    1974-01-01

    Results are presented for a static acoustic and propulsion performance ground test conducted at the Boeing hot nozzle facility on the C8A Buffalo noise suppressor nozzle. Various methods to remove a nozzle-associated 2000-Hz tone are evaluated. Results of testing this rectangular-array lobed nozzle for propulsion performance and acoustic directivity are reported. Recommendations for future nozzle modifications and further testing are included. Appendix A contains the test plan. Appendix B presents the test log. Appendix C contains plots of the one-third octave sound pressure levels recorded during the test. Appendix D describes the acoustic data recording and reduction systems. The performance data is tabulated in Appendix E.

  4. Multileaf collimator performance monitoring and improvement using semiautomated quality control testing and statistical process control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Létourneau, Daniel, E-mail: daniel.letourneau@rmp.uh.on.ca; McNiven, Andrea; Keller, Harald

    2014-12-15

    Purpose: High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process control tools, was developed. The MLC performance monitoring system was used for almost a year on two commercially available MLC models. Control charts were used to establish MLC performance and assess test frequency required to achieve a given level of performance. MLC-related interlocks and servicing events were recorded during the monitoring period and were investigated as indicators of MLC performance variations. Methods:more » The QC test developed as part of the MLC performance monitoring system uses 2D megavoltage images (acquired using an electronic portal imaging device) of 23 fields to determine the location of the leaves with respect to the radiation isocenter. The precision of the MLC performance monitoring QC test and the MLC itself was assessed by detecting the MLC leaf positions on 127 megavoltage images of a static field. After initial calibration, the MLC performance monitoring QC test was performed 3–4 times/week over a period of 10–11 months to monitor positional accuracy of individual leaves for two different MLC models. Analysis of test results was performed using individuals control charts per leaf with control limits computed based on the measurements as well as two sets of specifications of ±0.5 and ±1 mm. Out-of-specification and out-of-control leaves were automatically flagged by the monitoring system and reviewed monthly by physicists. MLC-related interlocks reported by the linear accelerator and servicing events were recorded to help identify potential causes of nonrandom MLC leaf positioning variations. Results: The precision of the MLC performance monitoring QC test and the MLC itself was within ±0.22 mm for most MLC leaves and the majority of the apparent leaf motion was attributed to beam spot displacements between irradiations. The MLC QC test was performed 193 and 162 times over the monitoring period for the studied units and recalibration had to be repeated up to three times on one of these units. For both units, rate of MLC interlocks was moderately associated with MLC servicing events. The strongest association with the MLC performance was observed between the MLC servicing events and the total number of out-of-control leaves. The average elapsed time for which the number of out-of-specification or out-of-control leaves was within a given performance threshold was computed and used to assess adequacy of MLC test frequency. Conclusions: A MLC performance monitoring system has been developed and implemented to acquire high-quality QC data at high frequency. This is enabled by the relatively short acquisition time for the images and automatic image analysis. The monitoring system was also used to record and track the rate of MLC-related interlocks and servicing events. MLC performances for two commercially available MLC models have been assessed and the results support monthly test frequency for widely accepted ±1 mm specifications. Higher QC test frequency is however required to maintain tighter specification and in-control behavior.« less

  5. Individual Characteristics and Unit Performance: A Review of Research and Methods

    DTIC Science & Technology

    1985-02-01

    behavioral segments, improves performance. Simu- lation exercises , especially those employing new high-technology devices, provide surrogate...high-technology training simulation exercise MOB Military Occupational Specialty ORTT Operational Readiness Training Test-a field test REALTRAIN A...REAListic TRAINing simulation exercise SAM Surface-to-Air Missile SAT Scholastic Aptitude Test SQT Skill Qualification Test-an Army performance meas

  6. Learner-Centered Instruction (LCI). Volume 5. Description of the Job Performance Test.

    ERIC Educational Resources Information Center

    Pieper, William J.; And Others

    An account is presented of the development of a job performance test for the Learner Centered Instruction (LCI) weapon control systems mechanic/technician Air Force course. The performance test was administered to the LCI experimental course subjects as well as the control course subjects upon graduation. Test items are, for the most part, based…

  7. An Experimental Study of the Effects of Stereotype Threat and Stereotype Lift on Men and Women's Performance in Mathematics

    ERIC Educational Resources Information Center

    Johnson, Heather J.; Barnard-Brak, Lucy; Saxon, Terrill F.; Johnson, Megan K.

    2012-01-01

    In this study the authors examined the differential effects of stereotype threat and lift between genders on math test performance. They asked 3 questions: (a) What is the effect of gender on math test performance?, (b) What is the effect of stereotyping condition (threat, lift, or neither) on math test performance?, and (c) What is the effect of…

  8. The Empirical Testing of a Musical Performance Assessment Paradigm

    ERIC Educational Resources Information Center

    Russell, Brian E.

    2010-01-01

    The purpose of this study was to test a hypothesized model of aurally perceived performer-controlled musical factors that influence assessments of performance quality. Previous research studies on musical performance constructs, musical achievement, musical expression, and scale construction were examined to identify the factors that influence…

  9. 40 CFR 60.52Da - Recordkeeping requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Electric Utility... opacity field data sheets; (2) For each performance test conducted using Method 22 of appendix A-4 of this... performance test; (iii) Copies of all visible emission observer opacity field data sheets; and (iv...

  10. Occupational-Specific Strength Predicts Astronaut-Related Task Performance in a Weighted Suit.

    PubMed

    Taylor, Andrew; Kotarsky, Christopher J; Bond, Colin W; Hackney, Kyle J

    2018-01-01

    Future space missions beyond low Earth orbit will require deconditioned astronauts to perform occupationally relevant tasks within a planetary spacesuit. The prediction of time-to-completion (TTC) of astronaut tasks will be critical for crew safety, autonomous operations, and mission success. This exploratory study determined if the addition of task-specific strength testing to current standard lower body testing would enhance the prediction of TTC in a 1-G test battery. Eight healthy participants completed NASA lower body strength tests, occupationally specific strength tests, and performed six task simulations (hand drilling, construction wrenching, incline walking, collecting weighted samples, and dragging an unresponsive crewmember to safety) in a 48-kg weighted suit. The TTC for each task was recorded and summed to obtain a total TTC for the test battery. Linear regression was used to predict total TTC with two models: 1) NASA lower body strength tests; and 2) NASA lower body strength tests + occupationally specific strength tests. Total TTC of the test battery ranged from 20.2-44.5 min. The lower body strength test alone accounted for 61% of the variability in total TTC. The addition of hand drilling and wrenching strength tests accounted for 99% of the variability in total TTC. Adding occupationally specific strength tests (hand drilling and wrenching) to standard lower body strength tests successfully predicted total TTC in a performance test battery within a weighted suit. Future research should couple these strength tests with higher fidelity task simulations to determine the utility and efficacy of task performance prediction.Taylor A, Kotarsky CJ, Bond CW, Hackney KJ. Occupational-specific strength predicts astronaut-related task performance in a weighted suit. Aerosp Med Hum Perform. 2018; 89(1):58-62.

  11. Associations between physical function, dual-task performance and cognition in patients with mild Alzheimer's disease.

    PubMed

    Sobol, Nanna Aue; Hoffmann, Kristine; Vogel, Asmus; Lolk, Annette; Gottrup, Hanne; Høgh, Peter; Hasselbalch, Steen G; Beyer, Nina

    2016-11-01

    Alzheimer's disease (AD) causes a gradual decline in cognition, limitations of dual-tasking and physical function leading to total dependence. Hence, information about the interaction between physical function, dual-task performance and cognition may lead to new treatment strategies with the purpose of preserving function and quality of life. The objective of this study was to investigate the associations between physical function, dual-task performance and cognition in community-dwelling patients with mild AD. Baseline results from 185 participants (50-90 years old) in the single blinded multicenter RCT 'ADEX' (Alzheimer's disease: the effect of physical exercise) were used. Assessments included tests of physical function: 400-m walk test, 10-m walk test, Timed Up and Go test and 30-s chair stand test; dual-task performance, i.e., 10-m walk while counting backwards from 50 or naming the months backwards; and cognition, i.e., Mini Mental State Examination, Symbol Digit Modalities Test, the Stroop Color and Word Test, and Lexical verbal fluency test. Results in the 30-s chair stand test correlated significantly with all tests of cognition (r = .208-.242) while the other physical function tests only randomly correlated with tests of cognition. Results in the dual-task counting backwards correlated significantly with results in all tests of cognition (r = .259-.388), which accounted for 7%-15% of the variation indicating that a faster time to complete dual-task performance was associated with better cognitive performance. The evidence of the associations between physical function, dual-task performance and cognition is important when creating new rehabilitation interventions to patients with mild AD.

  12. Purple L1 Milestone Review Panel GPFS Functionality and Performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loewe, W E

    2006-12-01

    The GPFS deliverable for the Purple system requires the functionality and performance necessary for ASC I/O needs. The functionality includes POSIX and MPIIO compatibility, and multi-TB file capability across the entire machine. The bandwidth performance required is 122.15 GB/s, as necessary for productive and defensive I/O requirements, and the metadata performance requirement is 5,000 file stats per second. To determine success for this deliverable, several tools are employed. For functionality testing of POSIX, 10TB-files, and high-node-count capability, the parallel file system bandwidth performance test IOR is used. IOR is an MPI-coordinated application that can write and then read to amore » single shared file or to an individual file per process and check the data integrity of the file(s). The MPIIO functionality is tested with the MPIIO test suite from the MPICH library. Bandwidth performance is tested using IOR for the required 122.15 GB/s sustained write. All IOR tests are performanced with data checking enabled. Metadata performance is tested after ''aging'' the file system with 80% data block usage and 20% inode usage. The fdtree metadata test is expected to create/remove a large directory/file structure in under 20 minutes time, akin to interactive metadata usage. Multiple (10) instances of ''ls -lR'', each performing over 100K stats, are run concurrently in different large directories to demonstrate 5,000 stats/sec.« less

  13. Computer versus paper--does it make any difference in test performance?

    PubMed

    Karay, Yassin; Schauber, Stefan K; Stosch, Christoph; Schüttpelz-Brauns, Katrin

    2015-01-01

    CONSTRUCT: In this study, we examine the differences in test performance between the paper-based and the computer-based version of the Berlin formative Progress Test. In this context it is the first study that allows controlling for students' prior performance. Computer-based tests make possible a more efficient examination procedure for test administration and review. Although university staff will benefit largely from computer-based tests, the question arises if computer-based tests influence students' test performance. A total of 266 German students from the 9th and 10th semester of medicine (comparable with the 4th-year North American medical school schedule) participated in the study (paper = 132, computer = 134). The allocation of the test format was conducted as a randomized matched-pair design in which students were first sorted according to their prior test results. The organizational procedure, the examination conditions, the room, and seating arrangements, as well as the order of questions and answers, were identical in both groups. The sociodemographic variables and pretest scores of both groups were comparable. The test results from the paper and computer versions did not differ. The groups remained within the allotted time, but students using the computer version (particularly the high performers) needed significantly less time to complete the test. In addition, we found significant differences in guessing behavior. Low performers using the computer version guess significantly more than low-performing students in the paper-pencil version. Participants in computer-based tests are not at a disadvantage in terms of their test results. The computer-based test required less processing time. The reason for the longer processing time when using the paper-pencil version might be due to the time needed to write the answer down, controlling for transferring the answer correctly. It is still not known why students using the computer version (particularly low-performing students) guess at a higher rate. Further studies are necessary to understand this finding.

  14. Performance-oriented packaging testing of PPP-B-601 ERAPS wood box for packing Group II solid hazardous material. Test report for Oct 91

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, E.

    1991-10-01

    Qualification tests were performed to determine whether the in-service PPP-B-601 ERAPS Wood Box could be utilized to contain properly dunnaged solid type hazardous materials weighing up to a gross weight of 237 kg (523 pounds). The tests were conducted in accordance with Performance Oriented Packaging (POP) requirements specified by the United Nations Recommendations on the Transportation of Dangerous Goods. The box has conformed to the POP performance requirements; i.e., the box successfully retained its contents throughout the stacking, vibration and drop tests.

  15. Memory functions in chronic pain: examining contributions of attention and age to test performance.

    PubMed

    Oosterman, Joukje M; Derksen, Laura C; van Wijck, Albert J M; Veldhuijzen, Dieuwke S; Kessels, Roy P C

    2011-01-01

    Previous studies have revealed that memory performance is diminished in chronic pain patients. Few studies, however, have assessed multiple components of memory in a single sample. It is currently also unknown whether attentional problems, which are commonly observed in chronic pain, mediate the decline in memory. Finally, previous studies have focused on middle-aged adults, and a possible detrimental effect of aging on memory performance in chronic pain patients has been commonly disregarded. This study, therefore, aimed at describing the pattern of semantic, working, and visual and verbal episodic memory performance in participants with chronic pain, while testing for possible contributions of attention and age to task performance. Thirty-four participants with chronic pain and 32 pain-free participants completed tests of episodic, semantic, and working memory to assess memory performance and a test of attention. Participants with chronic pain performed worse on tests of working memory and verbal episodic memory. A decline in attention explained some, but not all, group differences in memory performance. Finally, no additional effect of age on the diminished task performance in participants with chronic pain was observed. Taken together, the results indicate that chronic pain significantly affects memory performance. Part of this effect may be caused by underlying attentional dysfunction, although this could not fully explain the observed memory decline. An increase in age in combination with the presence of chronic pain did not additionally affect memory performance.

  16. Thermal Performance Testing of EMU and CSAFE Liquid Cooling Gannents

    NASA Technical Reports Server (NTRS)

    Rhodes, Richard; Bue, Grant; Meginnis, Ian; Hakam, Mary; Radford, Tamara

    2013-01-01

    Future exploration missions require the development of a new liquid cooling garment (LCG) to support the next generation extravehicular activity (EVA) suit system. The new LCG must offer greater system reliability, optimal thermal performance as required by mission directive, and meet other design requirements including improved tactile comfort. To advance the development of a future LCG, a thermal performance test was conducted to evaluate: (1) the comparable thermal performance of the EMU LCG and the CSAFE developed engineering evaluation unit (EEU) LCG, (2) the effect of the thermal comfort undergarment (TCU) on the EMU LCG tactile and thermal comfort, and (3) the performance of a torso or upper body only LCG shirt to evaluate a proposed auxiliary loop. To evaluate the thermal performance of each configuration, a metabolic test was conducted using the Demonstrator Spacesuit to create a relevant test environment. Three (3) male test subjects of similar height and weight walked on a treadmill at various speeds to produce three different metabolic loads - resting (300-600 BTU/hr), walking at a slow pace (1200 BTU/hr), and walking at a brisk pace (2200 BTU/hr). Each subject participated in five tests - two wearing the CSAFE full LCG, one wearing the EMU LCG without TCUs, one wearing the EMU LCG with TCUs, and one with the CSAFE shirt-only. During the test, performance data for the breathing air and cooling water systems and subject specific data was collected to define the thermal performance of the configurations. The test results show that the CSAFE EEU LCG and EMU LCG with TCU had comparable performance. The testing also showed that an auxiliary loop LCG, sized similarly to the shirt-only configuration, should provide adequate cooling for contingency scenarios. Finally, the testing showed that the TCU did not significantly hinder LCG heat transfer, and may prove to be acceptable for future suit use with additional analysis and testing.

  17. The effects of individual differences, prior experience and cognitive load on the transfer of dynamic decision-making performance.

    PubMed

    Nicholson, Brad; O'Hare, David

    2014-01-01

    Situational awareness is recognised as an important factor in the performance of individuals and teams in dynamic decision-making (DDM) environments (Salmon et al. 2014 ). The present study was designed to investigate whether the scores on the WOMBAT™ Situational Awareness and Stress Tolerance Test (Roscoe and North 1980 ) would predict the transfer of DDM performance from training under different levels of cognitive load to a novel situation. Participants practised a simulated firefighting task under either low or high conditions of cognitive load and then performed a (transfer) test in an alternative firefighting environment under an intermediate level of cognitive load. WOMBAT™ test scores were a better predictor of DDM performance than scores on the Raven Matrices. Participants with high WOMBAT™ scores performed better regardless of their training condition. Participants with recent gaming experience who practised under low cognitive load showed better practice phase performance but worse transfer performance than those who practised under high cognitive load. The relationship between task experience, situational awareness ability, cognitive load and the transfer of dynamic decision-making (DDM) performance was investigated. Results showed that the WOMBAT™ test predicted transfer of DDM performance regardless of task cognitive load. The effects of cognitive load on performance varied according to previous task-relevant experience.

  18. Cluster Detection Tests in Spatial Epidemiology: A Global Indicator for Performance Assessment

    PubMed Central

    Guttmann, Aline; Li, Xinran; Feschet, Fabien; Gaudart, Jean; Demongeot, Jacques; Boire, Jean-Yves; Ouchchane, Lemlih

    2015-01-01

    In cluster detection of disease, the use of local cluster detection tests (CDTs) is current. These methods aim both at locating likely clusters and testing for their statistical significance. New or improved CDTs are regularly proposed to epidemiologists and must be subjected to performance assessment. Because location accuracy has to be considered, performance assessment goes beyond the raw estimation of type I or II errors. As no consensus exists for performance evaluations, heterogeneous methods are used, and therefore studies are rarely comparable. A global indicator of performance, which assesses both spatial accuracy and usual power, would facilitate the exploration of CDTs behaviour and help between-studies comparisons. The Tanimoto coefficient (TC) is a well-known measure of similarity that can assess location accuracy but only for one detected cluster. In a simulation study, performance is measured for many tests. From the TC, we here propose two statistics, the averaged TC and the cumulated TC, as indicators able to provide a global overview of CDTs performance for both usual power and location accuracy. We evidence the properties of these two indicators and the superiority of the cumulated TC to assess performance. We tested these indicators to conduct a systematic spatial assessment displayed through performance maps. PMID:26086911

  19. Effects of Math Anxiety and Perfectionism on Timed versus Untimed Math Testing in Mathematically Gifted Sixth Graders

    PubMed Central

    Tsui, Joanne M.; Mazzocco, Michèle M. M.

    2009-01-01

    This study was designed to examine the effects of math anxiety and perfectionism on math performance, under timed testing conditions, among mathematically gifted sixth graders. We found that participants had worse math performance during timed versus untimed testing, but this difference was statistically significant only when the timed condition preceded the untimed condition. We also found that children with higher levels of either math anxiety or perfectionism had a smaller performance discrepancy during timed versus untimed testing, relative to children with lower levels of math anxiety or perfectionism. There were no statistically significant gender differences in overall test performance, nor in levels of math anxiety or perfectionism; however, the difference between performance on timed and untimed math testing was statistically significant for girls, but not for boys. Implications for educators are discussed. PMID:20084180

  20. Test Anxiety and Academic Performance among Undergraduates: The Moderating Role of Achievement Motivation.

    PubMed

    Balogun, Anthony Gbenro; Balogun, Shyngle Kolawole; Onyencho, Chidi Victor

    2017-02-13

    This study investigated the moderating role of achievement motivation in the relationship between test anxiety and academic performance. Three hundred and ninety three participants (192 males and 201 females) selected from a public university in Ondo State, Nigeria using a purposive sampling technique, participated in the study. They responded to measures of test anxiety and achievement motivation. Three hypotheses were tested using moderated hierarchical multiple regression analysis. Results showed that test anxiety had a negative impact on academic performance (β = -.23; p < .05). Achievement motivation had a positive impact on academic performance (β = .38; p < .05). Also, achievement motivation significantly moderated the relationship between test anxiety and academic performance (β = .10; p < .01). These findings suggest that university management should design appropriate psycho-educational interventions that would enhance students' achievement motivation.

  1. Keeping waived tests simple.

    PubMed

    2004-01-01

    Laboratories performing waived testing must follow the manufacturer's instructions as well as good laboratory practices to ensure that test results are reliable. Four things to concentrate on to maximize the performance and reliability of waived tests are to: 1. Read and follow the information found in the package inserts. 2. Follow the manufacturer's recommendations for running quality control. 3. Train staff members to perform tests correctly. 4. Follow established policies and procedures for patient testing in the practice.

  2. The impact of culture and education on non-verbal neuropsychological measurements: a critical review.

    PubMed

    Rosselli, Mónica; Ardila, Alfredo

    2003-08-01

    Clinical neuropsychology has frequently considered visuospatial and non-verbal tests to be culturally and educationally fair or at least fairer than verbal tests. This paper reviews the cross-cultural differences in performance on visuoperceptual and visuoconstructional ability tasks and analyzes the impact of education and culture on non-verbal neuropsychological measurements. This paper compares: (1) non-verbal test performance among groups with different educational levels, and the same cultural background (inter-education intra-culture comparison); (2) the test performance among groups with the same educational level and different cultural backgrounds (intra-education inter-culture comparisons). Several studies have demonstrated a strong association between educational level and performance on common non-verbal neuropsychological tests. When neuropsychological test performance in different cultural groups is compared, significant differences are evident. Performance on non-verbal tests such as copying figures, drawing maps or listening to tones can be significantly influenced by the individual's culture. Arguments against the use of some current neuropsychological non-verbal instruments, procedures, and norms in the assessment of diverse educational and cultural groups are discussed and possible solutions to this problem are presented.

  3. Thermal Performance of Cryogenic Piping Multilayer Insulation in Actual Field Installations

    NASA Technical Reports Server (NTRS)

    Fesmire, J.; Augustnynowicz, S.; Thompson, K. (Technical Monitor)

    2002-01-01

    A standardized way of comparing the thermal performance of different pipelines in different sizes is needed. Vendor data for vacuum-insulated piping are typically given in heat leak rate per unit length (W/m) for a specific diameter pipeline. An overall k-value for actual field installations (k(sub oafi)) is therefore proposed as a more generalized measure for thermal performance comparison and design calculation. The k(sub oafi) provides a direct correspondence to the k-values reported for insulation materials and illustrates the large difference between ideal multilayer insulation (MLI) and actual MLI performance. In this experimental research study, a section of insulated piping was tested under cryogenic vacuum conditions, including simulated spacers and bending. Several different insulation systems were tested using a 1-meter-long cylindrical cryostat test apparatus. The simulated spacers tests showed significant degradation in the thermal performance of a given insulation system. An 18-meter-long pipeline test apparatus is now in operation at the Cryogenics Test Laboratory, NASA Kennedy Space Center, for conducting liquid nitrogen thermal performance tests.

  4. Effect of trait anxiety on cognitive test performance in adolescents with and without attention-deficit/hyperactivity disorder.

    PubMed

    Ruf, Barbara M; Bessette, Katie L; Pearlson, Godfrey D; Stevens, Michael C

    2017-06-01

    Attention-deficit/hyperactivity disorder (ADHD) and anxiety are frequently comorbid disorders associated with different types of abnormal performance on neuropsychological tests. Although some studies have shown that comorbid anxiety alters ADHD test performance, results inconsistently show both improvements and worsening of different abilities, with failures to replicate across different anxiety disorders. Alternatively, trait anxiety may reflect a more stable influence on ADHD test performance than various diagnosable anxiety disorders. To better understand the possible enhancing or deleterious effects of anxiety on ADHD cognitive impairments, this study examined the effect of individual differences in trait anxiety measured by the Multidimensional Anxiety Scale for Children (MASC) on a battery of computerized, rapid-performance tests measuring attention and impulsivity-related performance in 98 Diagnostic and Statistical Manual of Mental Disorders-Fourth Edition (DSM-IV) Combined-Subtype ADHD adolescents and 123 healthy controls. It was hypothesized that trait anxiety would attenuate response inhibition and attention deficits in ADHD. ADHD-diagnosed adolescents with higher trait anxiety performed better on indices of sustained attention, reaction time, and motor variability, and had altered overall test-performance strategy, while response inhibition was affected in both ADHD and non-ADHD. This study provides the first evidence that pathological levels of anxiety are not needed to see differences in ADHD neuropsychological test performance. Instead, mildly elevated trait anxiety confers a protective influence by reducing the degree of impairment seen in ADHD. These findings suggest that better performing ADHD adolescents might have optimized levels of cortical arousal, and raise new questions about how best to identify the neurobiological substrates responsible for the beneficial effects.

  5. 47 CFR 76.1705 - Performance tests (channels delivered).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 4 2012-10-01 2012-10-01 false Performance tests (channels delivered). 76.1705 Section 76.1705 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Documents to be Maintained for Inspection § 76.1705 Performance tests (channels delivered). The...

  6. 47 CFR 76.1705 - Performance tests (channels delivered).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 4 2014-10-01 2014-10-01 false Performance tests (channels delivered). 76.1705 Section 76.1705 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Documents to be Maintained for Inspection § 76.1705 Performance tests (channels delivered). The...

  7. Performance statistics of the FORTRAN 4 /H/ library for the IBM system/360

    NASA Technical Reports Server (NTRS)

    Clark, N. A.; Cody, W. J., Jr.; Hillstrom, K. E.; Thieleker, E. A.

    1969-01-01

    Test procedures and results for accuracy and timing tests of the basic IBM 360/50 FORTRAN 4 /H/ subroutine library are reported. The testing was undertaken to verify performance capability and as a prelude to providing some replacement routines of improved performance.

  8. 33 CFR 183.53 - Horsepower capacity.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... considered because of the potential for exceeding the capabilities of the boat while performing the test... method discussed in paragraph (a) of this section, or for certain qualifying boats, the performance test... qualifying under this paragraph, the performance test method described in this paragraph may be used to...

  9. 33 CFR 183.53 - Horsepower capacity.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... considered because of the potential for exceeding the capabilities of the boat while performing the test... method discussed in paragraph (a) of this section, or for certain qualifying boats, the performance test... qualifying under this paragraph, the performance test method described in this paragraph may be used to...

  10. 33 CFR 183.53 - Horsepower capacity.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... considered because of the potential for exceeding the capabilities of the boat while performing the test... method discussed in paragraph (a) of this section, or for certain qualifying boats, the performance test... qualifying under this paragraph, the performance test method described in this paragraph may be used to...

  11. 33 CFR 183.53 - Horsepower capacity.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... considered because of the potential for exceeding the capabilities of the boat while performing the test... method discussed in paragraph (a) of this section, or for certain qualifying boats, the performance test... qualifying under this paragraph, the performance test method described in this paragraph may be used to...

  12. Acute coordinative exercise improves attentional performance in adolescents.

    PubMed

    Budde, Henning; Voelcker-Rehage, Claudia; Pietrabyk-Kendziorra, Sascha; Ribeiro, Pedro; Tidow, Günter

    2008-08-22

    Teachers complain about growing concentration deficits and reduced attention in adolescents. Exercise has been shown to positively affect cognitive performance. Due to the neuronal connection between the cerebellum and the frontal cortex, we hypothesized that cognitive performance might be influenced by bilateral coordinative exercise (CE) and that its effect on cognition might be already visible after short bouts of exercise. One hundred and fifteen healthy adolescents aged 13-16 years of an elite performance school were randomly assigned to an experimental and a control group and tested using the d2-test, a test of attention and concentration. Both groups performed the d2-test after a regular school lesson (pre-test), after 10 min of coordinative exercise and of a normal sport lesson (NSL, control group), respectively (post-test). Exercise was controlled for heart rate (HR). CE and NSL enhanced the d2-test performance from pre- to post-test significantly. ANOVA revealed a significant group (CE, NSL) by performance interaction in the d2-test indicating a higher improvement of CE as compared to NSL. HR was not significantly different between the groups. CE was more effective in completing the concentration and attention task. With the HR being the same in both groups we assume that the coordinative character of the exercise might be responsible for the significant differences. CE might lead to a pre-activation of parts of the brain which are also responsible for mediating functions like attention. Thus, our results support the request for more acute CE in schools, even in elite performance schools.

  13. Sub-maximal and maximal Yo-Yo intermittent endurance test level 2: heart rate response, reproducibility and application to elite soccer.

    PubMed

    Bradley, Paul S; Mohr, M; Bendiksen, M; Randers, M B; Flindt, M; Barnes, C; Hood, P; Gomez, A; Andersen, Jesper L; Di Mascio, M; Bangsbo, J; Krustrup, P

    2011-06-01

    The aims of this study were to (1) determine the reproducibility of sub-maximal and maximal versions of the Yo-Yo intermittent endurance test level 2 (Yo-Yo IE2 test), (2) assess the relationship between the Yo-Yo IE2 test and match performance and (3) quantify the sensitivity of the Yo-Yo IE2 test to detect test-retest changes and discriminate between performance for different playing standards and positions in elite soccer. Elite (n = 148) and sub-elite male (n = 14) soccer players carried out the Yo-Yo IE2 test on several occasions over consecutive seasons. Test-retest coefficient of variation (CV) in Yo-Yo IE2 test performance and heart rate after 6 min were 3.9% (n = 37) and 1.4% (n = 32), respectively. Elite male senior and youth U19 players Yo-Yo IE2 performances were better (P < 0.01) than elite youth U16s and sub-elite players (2,603 ± 451 and 2,534 ± 549 vs. 1,855 ± 535 vs. 1,749 ± 382 m). The intra- and inter-season CV for Yo-Yo IE2 test performance were 4.2 and 5.6%, respectively. A correlation was observed (P < 0.05) between Yo-Yo IE2 test performance and the total (r = 0.74) and high-intensity (r = 0.58) running distance covered in a match. A correlation was also evident (P < 0.01) between Yo-Yo IE2 test heart rate after 6 min expressed in percentage of maximal heart rate and the peak values for high-intensity running performed by midfielders in 5-min (r = -0.71), 15-min (r = -0.75) and 45-min periods (r = -0.77). The present data demonstrate that the Yo-Yo IE2 test is reproducible and can be used to determine the capacity of elite soccer players to perform intense intermittent exercise. Furthermore, the Yo-Yo IE2 test was shown to be a sensitive tool that not only relates to match performance but can also differentiate between intermittent exercise performance of players in various standards, stages of the season and playing positions.

  14. The Michigan Context and Performance Report Card: Public Elementary & Middle Schools, 2013

    ERIC Educational Resources Information Center

    Spalding, Audrey

    2013-01-01

    The Michigan Context and Performance Report Card measures school performance by adjusting standardized test scores to account for student background. Comparing schools using unadjusted test scores ignores the significant relationship between academic performance and student socioeconomic background--a dynamic outside a school's control. The…

  15. Rhythms of Mental Performance

    ERIC Educational Resources Information Center

    Valdez, Pablo; Reilly, Thomas; Waterhouse, Jim

    2008-01-01

    Cognitive performance is affected by an individual's characteristics and the environment, as well as by the nature of the task and the amount of practice at it. Mental performance tests range in complexity and include subjective estimates of mood, simple objective tests (reaction time), and measures of complex performance that require decisions to…

  16. Performing a Large-Scale Modal Test on the B2 Stand Crane at NASA's Stennis Space Center

    NASA Technical Reports Server (NTRS)

    Stasiunas, Eric C.; Parks, Russel A.

    2018-01-01

    A modal test of NASA’s Space Launch System (SLS) Core Stage is scheduled to occur prior to propulsion system verification testing at the Stennis Space Center B2 test stand. A derrick crane with a 180-ft long boom, located at the top of the stand, will be used to suspend the Core Stage in order to achieve defined boundary conditions. During this suspended modal test, it is expected that dynamic coupling will occur between the crane and the Core Stage. Therefore, a separate modal test was performed on the B2 crane itself, in order to evaluate the varying dynamic characteristics and correlate math models of the crane. Performing a modal test on such a massive structure was challenging and required creative test setup and procedures, including implementing both AC and DC accelerometers, and performing both classical hammer and operational modal analysis. This paper describes the logistics required to perform this large-scale test, as well as details of the test setup, the modal test methods used, and an overview of the results.

  17. The simplest acquisition protocol is sometimes the best protocol: performing and learning a 1:2 bimanual coordination task.

    PubMed

    Panzer, Stefan; Kennedy, Deanna; Wang, Chaoyi; Shea, Charles H

    2018-02-01

    An experiment was conducted to determine if the performance and learning of a multi-frequency (1:2) coordination pattern between the limbs are enhanced when a model is provided prior to each acquisition trial. Research has indicated very effective performance of a wide variety of bimanual coordination tasks when Lissajous plots with goal templates are provided, but this research has also found that participants become dependent on this information and perform quite poorly when it is withdrawn. The present experiment was designed to test three forms of modeling (Lissajous with template, Lissajous without template, and limb model), but in each situations, the model was presented prior to practice and not available during the performance of the task. This was done to decrease dependency on the model and increase the development of an internal reference of correctness that could be applied on test trials. A control condition was also collected, where a metronome was used to guide the movement. Following less than 7 min of practice, participants in the three modeling conditions performed the first test block very effectively; however, performance of the control condition was quite poor. Note that Test 1 was performed under the same conditions as used during acquisition. Test 2 was conducted with no augmented information provided prior to or during the performance of the task. Only participants in the limb model condition were able to maintain performance on Test 2. The findings suggest that a very simple intuitive display can provide the necessary information to form an effective internal representation of the coordination pattern which can be used guide performance when the augmented display is withdrawn.

  18. Academic self-concept, learning motivation, and test anxiety of the underestimated student.

    PubMed

    Urhahne, Detlef; Chao, Sheng-Han; Florineth, Maria Luise; Luttenberger, Silke; Paechter, Manuela

    2011-03-01

    BACKGROUND. Teachers' judgments of student performance on a standardized achievement test often result in an overestimation of students' abilities. In the majority of cases, a larger group of overestimated students and a smaller group of underestimated students are formed by these judgments. AIMS. In this research study, the consequences of the underestimation of students' mathematical performance potential were examined. SAMPLE. Two hundred and thirty-five fourth grade students and their fourteen mathematics teachers took part in the investigation. METHOD. Students worked on a standardized mathematics achievement test and completed a self-description questionnaire about motivation and affect. Teachers estimated each individual student's potential with regard to mathematics test performance as well as students' expectancy for success, level of aspiration, academic self-concept, learning motivation, and test anxiety. The differences between teachers' judgments on students' test performance and students' actual performance were used to build groups of underestimated and overestimated students. RESULTS. Underestimated students displayed equal levels of test performance, learning motivation, and level of aspiration in comparison with overestimated students, but had lower expectancy for success, lower academic self-concept, and experienced more test anxiety. Teachers expected that underestimated students would receive lower grades on the next mathematics test, believed that students were satisfied with lower grades, and assumed that the students have weaker learning motivation than their overestimated classmates. CONCLUSION. Teachers' judgment error was not confined to test performance but generalized to motivational and affective traits of the students. © 2010 The British Psychological Society.

  19. The effect of simulated weightlessness on performance and mood

    NASA Technical Reports Server (NTRS)

    Rosenberg, Bonnie

    1988-01-01

    The performance results of the bedrest study at Ames were not what were expected. The Air Combat Maneuvering performance test was tested to assure its reliability. However, the results from this study show a continued increase in performance. One would assume that scores would become constant if not decrease by the first days of bedrest because an inverted position would affect performance. It is also interesting to observe that while the subject's moods deteriorated, their performance improved. Although the performance results were surprising, the mood results were as expected.

  20. Effect of STS space suit on astronaut dominant upper limb EVA work performance

    NASA Technical Reports Server (NTRS)

    Greenisen, Michael C.

    1987-01-01

    The STS Space Suited and unsuited dominant upper limb performance was evaluated in order to quantify future EVA astronaut skeletal muscle upper limb performance expectations. Testing was performed with subjects standing in EVA STS foot restraints. Data was collected with a CYBEX Dynamometer enclosed in a waterproof container. Control data was taken in one g. During one g testing, weight of the Space Suit was relieved from the subject via an overhead crane with a special connection to the PLSS of the suit. Experimental data was acquired during simulated zero g, accomplished by neutral buoyancy in the Weightless Environment Training Facility. Unsuited subjects became neutrally buoyant via SCUBA BC vests. Actual zero g experimental data was collected during parabolic arc flights on board NASA's modified KC-135 aircraft. During all test conditions, subjects performed five EVA work tasks requiring dominant upper limb performance and ten individual joint articulation movements. Dynamometer velocities for each tested movement were 0 deg/sec, 30 or 60 deg/sec and 120 or 180 deg/sec, depending on the test, with three repetitions per test. Performance was measured in foot pounds of torque.

  1. The cortisol awakening response and memory performance in older men and women.

    PubMed

    Almela, Mercedes; van der Meij, Leander; Hidalgo, Vanesa; Villada, Carolina; Salvador, Alicia

    2012-12-01

    The activity and regulation of the hypothalamus-pituitary-adrenal axis has been related to cognitive decline during aging. This study investigated whether the cortisol awakening response (CAR) is related to memory performance among older adults. The sample was composed of 88 participants (44 men and 44 women) from 55 to 77 years old. The memory assessment consisted of two tests measuring declarative memory (a paragraph recall test and a word list learning test) and two tests measuring working memory (a spatial span test and a spatial working memory test). Among those participants who showed the CAR on two consecutive days, we found that a greater CAR was related to poorer declarative memory performance in both men and women, and to better working memory performance only in men. The results of our study suggest that the relationship between CAR and memory performance is negative in men and women when memory performance is largely dependent on hippocampal functioning (i.e. declarative memory), and positive, but only in men, when memory performance is largely dependent on prefrontal cortex functioning (i.e. working memory). Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Effect of wrist cooling on aerobic and anaerobic performance in elite sportsmen.

    PubMed

    Krishnan, Anup; Singh, Krishan; Sharma, Deep; Upadhyay, Vivekanand; Singh, Amit

    2018-01-01

    Body cooling has been used to increase sporting performance and enhance recovery. Several studies have reported improvement in exercise capacities using forearm and hand cooling or only hand cooling. Wrist cooling has emerged as a portable light weight solution for precooling prior to sporting activity. The Astrand test for aerobic performance and the Wingate test for anaerobic performance are reliable and accurate tests for performance assessment. This study conducted on elite Indian athletes analyses the effects of wrist precooling on aerobic and anaerobic performance as tested by the Astrand test and the Wingate test before and after wrist precooling. 67 elite sportsmen were administered Wingate and Astrand test under standardised conditions with and without wrist precooling using a wrist cooling device (dhamaSPORT). Paired t -test was applied to study effect on aerobic [VO 2 (ml/min/kg)] and anaerobic performance [peak power (W/kg) and average power (W/kg)] and Cohen's d was used to calculate effect size of wrist precooling. After wrist precooling, significant increase of 0.22 ( p  = 0.014, 95% CI: 0.047, 0.398) in peak power (W/kg) and 0.22 ( p  < 0.0001, 95% CI: 0.142, 0.291) was observed in average power (W/kg). Although, an increase of 1.38 ( p  = 0.097, 95% CI: -0.225, 3.012) was observed in VO 2 (ml/min/kg), wrist precooling was not significantly effective in aerobic performance. Wrist cooling effect size was smaller in VO 2 (Cohen's d  = 0.21), peak power (Cohen's d  = 0.31) and it was larger in average power (Cohen's d  = 0.71). Results show wrist precooling significantly improves anaerobic than aerobic performance of elite sportsmen.

  3. Blood pressure and neuropsychological test performance in healthy postmenopausal women.

    PubMed

    Alsumali, Adnan; Mekary, Rania A; Seeger, John; Regestein, Quentin

    2016-06-01

    To study the association between blood pressure and neuropsychological test performance in healthy postmenopausal women. Data from 88 healthy postmenopausal women aged 46-73 years, who were not experiencing hot flashes, and who had participated in a prior drug trial, were analyzed to find whether baseline blood pressure was associated with impaired performance on neuropsychological testing done at 3 follow-up visits separated by 4 weeks. Factor analysis was used to reduce the dimensions of neuropsychological test performance. Mixed linear modeling was used to evaluate the association between baseline blood pressure and repeatedly measured neuropsychological test performance at follow-up in a complete case analysis (n=53). In a sensitivity analysis (n=88), multiple-imputation using the Markov Chain Monte Carlo method was used to account for missing data (blood pressure results) for some visits. The variables recording neuropsychological test performance were reduced to two main factors (Factor 1=selective attention; Factor 2=complex processing). In the complete case analysis, the association between a 20-mmHg increase in diastolic blood pressure and Factor 1 remained statistically significant after adjusting for potential confounders, before adjusting for systolic blood pressure (slope=0.60; 95%CI=0.04,1.16), and after adjusting for systolic blood pressure (slope=0.76; 95%CI=0.06, 1.47). The positive slopes indicated an increase in the time spent performing a given task (i.e., a decrease in neuropsychological test performance). No other significant associations were found between systolic blood pressure and either factor. The results did not materially change after applying the multiple-imputation method. An increase in diastolic blood pressure was associated with a decrease in neuropsychological test performance among older healthy postmenopausal women experiencing hot flashes. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. Performance on a work-simulating firefighter test versus approved laboratory tests for firefighters and applicants.

    PubMed

    von Heimburg, Erna; Medbø, Jon Ingulf; Sandsund, Mariann; Reinertsen, Randi Eidsmo

    2013-01-01

    Firefighters must meet minimum physical demands. The Norwegian Labour Inspection Authority (NLIA) has approved a standardised treadmill walking test and 3 simple strength tests for smoke divers. The results of the Trondheim test were compared with those of the NLIA tests taking into account possible effects of age, experience level and gender. Four groups of participants took part in the tests: 19 young experienced firefighters, 24 senior male firefighters and inexperienced applicants, 12 male and 8 female. Oxygen uptake (VO2) at exhaustion rose linearly by the duration of the treadmill test. Time spent on the Trondheim test was closely related to performance time and peak VO2 on the treadmill test. Senior experienced firefighters did not perform better than equally fit young applicants. However, female applicants performed poorer on the Trondheim test than on the treadmill test. Performance on the Trondheim test was not closely related to muscle strength beyond a minimum. CONCLUSION. Firefighters completing the Trondheim test in under 19 min fit the requirements of the NLIA treadmill test. The Trondheim test can be used as an alternative to the NLIA tests for testing aerobic fitness but not for muscular strength. Women's result of the Trondheim test were poorer than the results of the NLIA treadmill test, probably because of their lower body mass.

  5. Structural, Thermal, and Optical Performance (STOP) Modeling and Results for the James Webb Space Telescope Integrated Science Instrument Module

    NASA Technical Reports Server (NTRS)

    Gracey, Renee; Bartoszyk, Andrew; Cofie, Emmanuel; Comber, Brian; Hartig, George; Howard, Joseph; Sabatke, Derek; Wenzel, Greg; Ohl, Raymond

    2016-01-01

    The James Webb Space Telescope includes the Integrated Science Instrument Module (ISIM) element that contains four science instruments (SI) including a Guider. We performed extensive structural, thermal, and optical performance(STOP) modeling in support of all phases of ISIM development. In this paper, we focus on modeling and results associated with test and verification. ISIMs test program is bound by ground environments, mostly notably the 1g and test chamber thermal environments. This paper describes STOP modeling used to predict ISIM system performance in 0g and at various on-orbit temperature environments. The predictions are used to project results obtained during testing to on-orbit performance.

  6. 40 CFR 600.207-12 - Calculation and use of vehicle-specific 5-cycle-based fuel economy and CO2 emission values for...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... economy and CO2 emission values from the tests performed using gasoline or diesel test fuel. (ii) Calculate the 5-cycle city and highway fuel economy and CO2 emission values from the tests performed using alcohol or natural gas test fuel, if 5-cycle testing has been performed. Otherwise, the procedure in § 600...

  7. 40 CFR 600.209-12 - Calculation of vehicle-specific 5-cycle fuel economy and CO2 emission values for a model type.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... city and highway fuel economy and CO2 emission values from the tests performed using gasoline or diesel test fuel. (ii) If 5-cycle testing was performed on the alcohol or natural gas test fuel, calculate the city and highway fuel economy and CO2 emission values from the tests performed using alcohol or natural...

  8. 40 CFR 600.209-12 - Calculation of vehicle-specific 5-cycle fuel economy and CO2 emission values for a model type.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... city and highway fuel economy and CO2 emission values from the tests performed using gasoline or diesel test fuel. (ii) If 5-cycle testing was performed on the alcohol or natural gas test fuel, calculate the city and highway fuel economy and CO2 emission values from the tests performed using alcohol or natural...

  9. 40 CFR 600.207-12 - Calculation and use of vehicle-specific 5-cycle-based fuel economy and CO2 emission values for...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... economy and CO2 emission values from the tests performed using gasoline or diesel test fuel. (ii) Calculate the 5-cycle city and highway fuel economy and CO2 emission values from the tests performed using alcohol or natural gas test fuel, if 5-cycle testing has been performed. Otherwise, the procedure in § 600...

  10. 40 CFR 600.209-12 - Calculation of vehicle-specific 5-cycle fuel economy and CO2 emission values for a model type.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... city and highway fuel economy and CO2 emission values from the tests performed using gasoline or diesel test fuel. (ii) If 5-cycle testing was performed on the alcohol or natural gas test fuel, calculate the city and highway fuel economy and CO2 emission values from the tests performed using alcohol or natural...

  11. 40 CFR 600.207-12 - Calculation and use of vehicle-specific 5-cycle-based fuel economy and CO2 emission values for...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... economy and CO2 emission values from the tests performed using gasoline or diesel test fuel. (ii) Calculate the 5-cycle city and highway fuel economy and CO2 emission values from the tests performed using alcohol or natural gas test fuel, if 5-cycle testing has been performed. Otherwise, the procedure in § 600...

  12. Realistic Development and Testing of Fission System at a Non-Nuclear Testing Facility

    NASA Technical Reports Server (NTRS)

    Godfroy, Tom; VanDyke, Melissa; Dickens, Ricky; Pedersen, Kevin; Lenard, Roger; Houts, Mike

    2000-01-01

    The use of resistance heaters to simulate heat from fission allows extensive development of fission systems to be performed in non-nuclear test facilities, saving time and money. Resistance heated tests on a module has been performed at the Marshall Space Flight Center in the Propellant Energy Source Testbed (PEST). This paper discusses the experimental facilities and equipment used for performing resistance heated tests. Recommendations are made for improving non-nuclear test facilities and equipment for simulated testing of nuclear systems.

  13. Realistic development and testing of fission systems at a non-nuclear testing facility

    NASA Astrophysics Data System (ADS)

    Godfroy, Tom; van Dyke, Melissa; Dickens, Ricky; Pedersen, Kevin; Lenard, Roger; Houts, Mike

    2000-01-01

    The use of resistance heaters to simulate heat from fission allows extensive development of fission systems to be performed in non-nuclear test facilities, saving time and money. Resistance heated tests on a module has been performed at the Marshall Space Flight Center in the Propellant Energy Source Testbed (PEST). This paper discusses the experimental facilities and equipment used for performing resistance heated tests. Recommendations are made for improving non-nuclear test facilities and equipment for simulated testing of nuclear systems. .

  14. Developing measures of fatigue using an alcohol comparison to validate the effects of fatigue on performance.

    PubMed

    Williamson, A M; Feyer, A M; Mattick, R P; Friswell, R; Finlay-Brown, S

    2001-05-01

    The effects of 28 h of sleep deprivation were compared with varying doses of alcohol up to 0.1% blood alcohol concentration (BAC) in the same subjects. The study was conducted in the laboratory. Twenty long-haul truck drivers and 19 people not employed as professional drivers acted as subjects. Tests were selected that were likely to be affected by fatigue, including simple reaction time, unstable tracking, dual task, Mackworth clock vigilance test, symbol digit coding, visual search, sequential spatial memory and logical reasoning. While performance effects were seen due to alcohol for all tests, sleep deprivation affected performance on most tests, but had no effect on performance on the visual search and logical reasoning tests. Some tests showed evidence of a circadian rhythm effect on performance, in particular, simple reaction time, dual task, Mackworth clock vigilance, and symbol digit coding, but only for response speed and not response accuracy. Drivers were slower but more accurate than controls on the symbol digit test, suggesting that they took a more conservative approach to performance of this test. This study demonstrated which tests are most sensitive to sleep deprivation and fatigue. The study therefore has established a set of tests that can be used in evaluations of fatigue and fatigue countermeasures.

  15. Assessing the Impact of Clothing and Individual Equipment (CIE) on Soldier Physical, Biomechanical, and Cognitive Performance Part 1: Test Methodology

    DTIC Science & Technology

    2018-02-01

    29 during Soldier Equipment Configuration Impact on Performance: Establishing a Test Methodology for the...Performance of Medium Rucksack Prototypes An investigation: Comparison of live-fire and weapon simulator test methodologies and the of three extremity armor

  16. 40 CFR 63.805 - Performance test methods.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Performance test methods. 63.805...) National Emission Standards for Wood Furniture Manufacturing Operations § 63.805 Performance test methods. (a)(1) The EPA Method 311 of appendix A of part 63 shall be used in conjunction with formulation data...

  17. Performance test for a solar water heater

    NASA Technical Reports Server (NTRS)

    1979-01-01

    Two reports describe procedures and results of performance tests on domestic solar powered hot water system. Performance tests determine amount of energy collected by system, amount of energy delivered to solar source, power required to operate system and maintain proper tank temperature, overall system efficiency, and temperature distribution in tank.

  18. 40 CFR 60.255 - Performance tests and other compliance requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Preparation and Processing Plants § 60.255 Performance tests and other compliance requirements. (a) An owner... within a 60-minute period of) PM performance tests. (c) If any affected coal processing and conveying...) when the coal preparation and processing plant is in operation. Each observation must be recorded as...

  19. 40 CFR 60.255 - Performance tests and other compliance requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Preparation and Processing Plants § 60.255 Performance tests and other compliance requirements. (a) An owner... within a 60-minute period of) PM performance tests. (c) If any affected coal processing and conveying...) when the coal preparation and processing plant is in operation. Each observation must be recorded as...

  20. 40 CFR 60.255 - Performance tests and other compliance requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Preparation and Processing Plants § 60.255 Performance tests and other compliance requirements. (a) An owner... within a 60-minute period of) PM performance tests. (c) If any affected coal processing and conveying...) when the coal preparation and processing plant is in operation. Each observation must be recorded as...

  1. 40 CFR 60.255 - Performance tests and other compliance requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Preparation and Processing Plants § 60.255 Performance tests and other compliance requirements. (a) An owner... within a 60-minute period of) PM performance tests. (c) If any affected coal processing and conveying...) when the coal preparation and processing plant is in operation. Each observation must be recorded as...

  2. 40 CFR 60.102a - Emissions limitations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the initial performance test, required by § 60.8, is completed, but not later than 60 days after... fall below the level established during the most recent performance test; and (ii) The daily average exhaust coke burn-off rate must not exceed the level established during the most recent performance test...

  3. 40 CFR 60.102a - Emissions limitations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the initial performance test, required by § 60.8, is completed, but not later than 60 days after... fall below the level established during the most recent performance test; and (ii) The daily average exhaust coke burn-off rate must not exceed the level established during the most recent performance test...

  4. 42 CFR 493.25 - Laboratories performing tests of high complexity.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Laboratories performing tests of high complexity. 493.25 Section 493.25 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND....25 Laboratories performing tests of high complexity. (a) A laboratory must obtain a certificate for...

  5. 42 CFR 493.25 - Laboratories performing tests of high complexity.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Laboratories performing tests of high complexity. 493.25 Section 493.25 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND....25 Laboratories performing tests of high complexity. (a) A laboratory must obtain a certificate for...

  6. 40 CFR 60.2155 - May I conduct performance testing less often?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... pollutant (particulate matter, hydrogen chloride, or opacity) over 3 consecutive years show that you comply... limitation for particulate matter, hydrogen chloride, or opacity, you may choose to conduct performance tests... matter, hydrogen chloride, or opacity, you must conduct annual performance tests for that pollutant until...

  7. 49 CFR 563.10 - Crash test performance and survivability.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 6 2011-10-01 2011-10-01 false Crash test performance and survivability. 563.10 Section 563.10 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION EVENT DATA RECORDERS § 563.10 Crash test performance and survivability. (a) Each...

  8. Stereotype Threat in Middle School: The Effects of Prior Performance on Expectancy and Test Performance

    ERIC Educational Resources Information Center

    Howard, Keith E.; Anderson, Kenneth A.

    2010-01-01

    Stereotype threat research has demonstrated how presenting situational cues in a testing environment, such as raising the salience of negative stereotypes, can adversely affect test performance (Perry, Steele, & Hilliard, 2003; Steele & Aronson, 1995) and expectancy (Cadinu, Maass, Frigerio, Impagliazzo, & Latinotti, 2003; Stangor,…

  9. The Effects of Written Comments on Student Performance.

    ERIC Educational Resources Information Center

    Leauby, Bruce A.; Atkinson, Maryanne

    1989-01-01

    Three accounting teachers gave two tests and a comprehensive final to 417 undergraduates using one of three treatments: no comments written on test paper, comments at teacher's discretion, or standard comments. The type of comment did not affect subsequent test performance, but did significantly affect performance on final exam, especially for…

  10. 40 CFR 63.1384 - Performance test requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... performance test, the owner or operator must monitor and record the glass pull rate for each glass-melting furnace and, if different, the glass pull rate for each rotary spin manufacturing line and flame attenuation manufacturing line. Record the glass pull rate every 15 minutes during any performance test...

  11. 40 CFR 63.5991 - By what date must I conduct an initial compliance demonstration or performance test?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... compliance demonstration or performance test? 63.5991 Section 63.5991 Protection of Environment ENVIRONMENTAL... POLLUTANTS FOR SOURCE CATEGORIES National Emissions Standards for Hazardous Air Pollutants: Rubber Tire... initial compliance demonstration or performance test? (a) If you have a new or reconstructed affected...

  12. The Relation between Self-Selected Study Processes and Test Performance.

    ERIC Educational Resources Information Center

    Nist, Sherrie L.; And Others

    1991-01-01

    A correlational study examined the relationship between test performance and four study processes (encoding, word meaning, organizing, and executive control). Results with 123 college freshmen trained to use study strategies suggest that executive control is related to test performance and that trained subjects select a variety of strategies…

  13. 40 CFR 63.7940 - By what date must I conduct performance tests or other initial compliance demonstrations?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... compliance is not demonstrated using a performance test or design evaluation, you must demonstrate initial... performance tests or other initial compliance demonstrations? 63.7940 Section 63.7940 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS...

  14. High Speed Prototype Car Test

    NASA Image and Video Library

    2014-01-10

    CAPE CANAVERAL, Fla. - A Hennessey Venom GT stands on the 3.5-mile long runway between test runs at the Shuttle Landing Facility at NASA's Kennedy Space Center in Florida. The flat concrete runway is one of the few places in the world where high performance automobiles can be tested for aerodynamic and safety designs. Hennessey Performance of Sealy, Texas, worked with Performance Power Racing in West Palm Beach to arrange use of the NASA facility. Performance Power Racing has conducted numerous engineering tests on the runway with a variety of vehicles. Photo credit: NASA/Kim Shiflett

  15. SCPS-TP, TCP, and Rate-Based Protocol Evaluation. Revised

    NASA Technical Reports Server (NTRS)

    Tran, Diepchi T.; Lawas-Grodek, Frances J.; Dimond, Robert P.; Ivancic, William D.

    2005-01-01

    Tests were performed at Glenn Research Center to compare the performance of the Space Communications Protocol Standard Transport Protocol (SCPS TP, otherwise known as "TCP Tranquility") relative to other variants of TCP and to determine the implementation maturity level of these protocols, particularly for higher speeds. The testing was performed over reasonably high data rates of up to 100 Mbps with delays that are characteristic of near-planetary environments. The tests were run for a fixed packet size, but for variously errored environments. This report documents the testing performed to date.

  16. Performance Evaluation Test of the Rapid Area Preparation Tool (RAPTOR)

    DTIC Science & Technology

    2008-12-01

    the standard SETCO tires. A blast test of the new SETCO tire is scheduled for the spring of...Washington, DC 20301-2500 Performance Evaluation Test of the Rapid Area Preparation Tool (RAPTOR) December 2008 Prepared ...2008 to 00-00-2008 4. TITLE AND SUBTITLE Performance Evaluation Test of the Rapid Area Preparation Tool (RAPTOR) 5a. CONTRACT NUMBER 5b.

  17. Investigating the Validity of an Integrated Listening-Speaking Task: A Discourse-Based Analysis of Test Takers' Oral Performances

    ERIC Educational Resources Information Center

    Frost, Kellie; Elder, Catherine; Wigglesworth, Gillian

    2012-01-01

    Performance on integrated tasks requires candidates to engage skills and strategies beyond language proficiency alone, in ways that can be difficult to define and measure for testing purposes. While it has been widely recognized that stimulus materials impact test performance, our understanding of the way in which test takers make use of these…

  18. Research of laser stealth performance test technology

    NASA Astrophysics Data System (ADS)

    Chen, Zhen-xing; Shi, Sheng-bing; Han, Fu-li; Wu, Yan-lin; Song, Chun-yan

    2014-09-01

    Laser stealth is an important way of photoelectric stealth weapons systems. According to operational principle of laser range finder, we actively explore and study the stealth performance approval testing technology of laser stealth materials, and bring forward and establish the stealth performance field test methods of stealth efficiency evaluation. Through contrastive test of two kinds of materials, the method is correct and effective.

  19. New method for rapid testing of bond strength for wood adhesives

    Treesearch

    James M. Wescott; Michael J. Birkeland; Amy E. Traska; Charles R. Frihart; Brice N. Dally

    2007-01-01

    In developing new adhesives for wood bonding, the testing of bond performance can often be a limiting factor in the development process. Evaluating the bond performance of an adhesive that can be prepared in less than a day often takes several days using standard performance tests. This testing slows the development process and may cause a company to abandon a...

  20. Validity, Reliability, and Sensitivity of a Volleyball Intermittent Endurance Test.

    PubMed

    Rodríguez-Marroyo, Jose A; Medina-Carrillo, Javier; García-López, Juan; Morante, Juan C; Villa, José G; Foster, Carl

    2017-03-01

    To analyze the concurrent and construct validity of a volleyball intermittent endurance test (VIET). The VIET's test-retest reliability and sensitivity to assess seasonal changes was also studied. During the preseason, 71 volleyball players of different competitive levels took part in this study. All performed the VIET and a graded treadmill test with gas-exchange measurement (GXT). Thirty-one of the players performed an additional VIET to analyze the test-retest reliability. To test the VIET's sensitivity, 28 players repeated the VIET and GXT at the end of their season. Significant (P < .001) relationships between VIET distance and maximal oxygen uptake (r = .74) and GXT maximal speed (r = .78) were observed. There were no significant differences between the VIET performance test and retest (1542.1 ± 338.1 vs 1567.1 ± 358.2 m). Significant (P < .001) relationships and intraclass correlation coefficient (ICC) were found (r = .95, ICC = .96) for VIET performance. VIET performance increased significantly (P < .001) with player performance level and was sensitive to fitness changes across the season (1458.8 ± 343.5 vs 1581.1 ± 334.0 m, P < .01). The VIET may be considered a valid, reliable, and sensitive test to assess the aerobic endurance in volleyball players.

  1. Predicting Performance in Higher Education Using Proximal Predictors.

    PubMed

    Niessen, A Susan M; Meijer, Rob R; Tendeiro, Jorge N

    2016-01-01

    We studied the validity of two methods for predicting academic performance and student-program fit that were proximal to important study criteria. Applicants to an undergraduate psychology program participated in a selection procedure containing a trial-studying test based on a work sample approach, and specific skills tests in English and math. Test scores were used to predict academic achievement and progress after the first year, achievement in specific course types, enrollment, and dropout after the first year. All tests showed positive significant correlations with the criteria. The trial-studying test was consistently the best predictor in the admission procedure. We found no significant differences between the predictive validity of the trial-studying test and prior educational performance, and substantial shared explained variance between the two predictors. Only applicants with lower trial-studying scores were significantly less likely to enroll in the program. In conclusion, the trial-studying test yielded predictive validities similar to that of prior educational performance and possibly enabled self-selection. In admissions aimed at student-program fit, or in admissions in which past educational performance is difficult to use, a trial-studying test is a good instrument to predict academic performance.

  2. Pad stress tests with increasing load for the diagnosis of stress urinary incontinence.

    PubMed

    Rimstad, Liv; Larsen, Elsa Skjønhaug; Schiøtz, Hjalmar A; Kulseng-Hanssen, Sigurd

    2014-09-01

    The aim of the study was to test the ability of pad stress tests with increasing load (supine, jumping on the floor, and jumping on a trampoline) to document stress incontinence in subjectively stress incontinent women. In this prospective study 147 subjectively stress and mixed incontinent women performed consecutively the three pad stress tests with a bladder volume of 300 ml. Nineteen women performed a second trampoline pad stress test to test repeatability of the test. Nine continent women performed a trampoline pad stress test in order to determine if subjectively continent women would leak during the test. Seventy-two women (49%) leaked during the supine, 136 (93%) leaked during the jumping, and 146 (99%) leaked during the trampoline pad stress test. The differences between pad stress tests were significant with P < 0.005. Correlation between the two trampoline pad stress tests was high at 0.8. None of the nine continent women leaked during the trampoline pad stress test. The supine pad stress test has low sensitivity and is therefore often falsely negative. The jumping pad stress test is a simple test to perform and is satisfactory for everyday use. Subjectively stress incontinent women who do not leak during the jumping pad stress test may perform a trampoline pad stress test to document stress incontinence. The trampoline pad stress test is also simple to perform and detected leakage in 91% of the women who did not leak during the jumping pad stress test. © 2013 Wiley Periodicals, Inc.

  3. Effects of Electric Vehicle Fast Charging on Battery Life and Vehicle Performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matthew Shirk; Jeffrey Wishart

    2015-04-01

    As part of the U.S. Department of Energy’s Advanced Vehicle Testing Activity, four new 2012 Nissan Leaf battery electric vehicles were instrumented with data loggers and operated over a fixed on-road test cycle. Each vehicle was operated over the test route, and charged twice daily. Two vehicles were charged exclusively by AC level 2 EVSE, while two were exclusively DC fast charged with a 50 kW charger. The vehicles were performance tested on a closed test track when new, and after accumulation of 50,000 miles. The traction battery packs were removed and laboratory tested when the vehicles were new, andmore » at 10,000-mile intervals. Battery tests include constant-current discharge capacity, electric vehicle pulse power characterization test, and low peak power tests. The on-road testing was carried out through 70,000 miles, at which point the final battery tests were performed. The data collected over 70,000 miles of driving, charging, and rest are analyzed, including the resulting thermal conditions and power and cycle demands placed upon the battery. Battery performance metrics including capacity, internal resistance, and power capability obtained from laboratory testing throughout the test program are analyzed. Results are compared within and between the two groups of vehicles. Specifically, the impacts on battery performance, as measured by laboratory testing, are explored as they relate to battery usage and variations in conditions encountered, with a primary focus on effects due to the differences between AC level 2 and DC fast charging. The contrast between battery performance degradation and the effect on vehicle performance is also explored.« less

  4. Evaluation of 2 cognitive abilities tests in a dual-task environment

    NASA Technical Reports Server (NTRS)

    Vidulich, M. A.; Tsang, P. S.

    1986-01-01

    Most real world operators are required to perform multiple tasks simultaneously. In some cases, such as flying a high performance aircraft or trouble shooting a failing nuclear power plant, the operator's ability to time share or process in parallel" can be driven to extremes. This has created interest in selection tests of cognitive abilities. Two tests that have been suggested are the Dichotic Listening Task and the Cognitive Failures Questionnaire. Correlations between these test results and time sharing performance were obtained and the validity of these tests were examined. The primary task was a tracking task with dynamically varying bandwidth. This was performed either alone or concurrently with either another tracking task or a spatial transformation task. The results were: (1) An unexpected negative correlation was detected between the two tests; (2) The lack of correlation between either test and task performance made the predictive utility of the tests scores appear questionable; (3) Pilots made more errors on the Dichotic Listening Task than college students.

  5. Evaluation of the performance of the OneTouch Select Plus blood glucose test system against ISO 15197:2013.

    PubMed

    Setford, Steven; Smith, Antony; McColl, David; Grady, Mike; Koria, Krisna; Cameron, Hilary

    2015-01-01

    Assess laboratory and in-clinic performance of the OneTouch Select(®) Plus test system against ISO 15197:2013 standard for measurement of blood glucose. System performance assessed in laboratory against key patient, environmental and pharmacologic factors. User performance was assessed in clinic by system-naïve lay-users. Healthcare professionals assessed system accuracy on diabetes subjects in clinic. The system demonstrated high levels of performance, meeting ISO 15197:2013 requirements in laboratory testing (precision, linearity, hematocrit, temperature, humidity and altitude). System performance was tested against 28 interferents, with an adverse interfering effect only being recorded for pralidoxime iodide. Clinic user performance results fulfilled ISO 15197:2013 accuracy criteria. Subjects agreed that the color range indicator clearly showed if they were low, in-range or high and helped them better understand glucose results. The system evaluated is accurate and meets all ISO 15197:2013 requirements as per the tests described. The color range indicator helped subjects understand glucose results and supports patients in following healthcare professional recommendations on glucose targets.

  6. Train the brain: immediate sensorimotor effects of mentally performed flexor exercises in patients with neck pain. A pilot study.

    PubMed

    Beinert, Konstantin; Sofsky, Marc; Trojan, Jörg

    2018-05-09

    Sensorimotor tests, like cranio- cervical flexion and cervical joint position sense tests, share a strong cognitive component during their execution. However, cognitive training for those tests has not been investigated so far. To compare mental and physical exercises for improving the sensorimotor function of the cervical spine. A within-subject design with 16 participants. Outpatient physiotherapy centre. Patients with chronic neck pain. Participants were instructed to perform specific active or mental exercises for the deep and superficial neck flexor muscles. The primary outcomes were cranio-cervical flexion test performance, postural sway, cervical joint position sense and pressure pain threshold. A mixed model analysis was used. The interventions improved cranio-cervical flexion performance (p < 0.001), with no difference between actively or mentally performed exercises. Postural sway increased after actively (p < 0.01) and mentally (p < 0.05) performed deep cervical neck flexor exercises, but not after superficial neck flexor exercises. Mentally performed superficial neck flexor exercises improved cervical joint position sense when compared to mentally performed deep cervical flexor exercises (p < 0.05), and actively performed superficial neck flexor exercises were effective in improving cervical joint position sense acuity compared to mentally performed deep cervical flexor exercises (p < 0.05) for relocation tasks in the transverse plane. The pressure pain threshold at the cervical spine increased after active deep cervical flexor exercises (p < 0.05) and after mental superficial neck flexor exercise (p < 0.05). Mentally performed deep cervical flexor exercises improved cranio-cervical flexion test performance, postural sway and pressure pain threshold at the cervical spine. Mentally performed superficial neck flexor exercises improved cervical joint position sense acuity more than mentally performed deep cervical flexor exercises. Mentally performed exercises are recommended in the early stages of rehabilitation to counteract extensive muscle impairment, and these can be incorporated into daily routine.

  7. A review of cryogenic testing performed by the thermochemical test branch, Manned Spacecraft Center in support of Apollo 13 and14

    NASA Technical Reports Server (NTRS)

    Propp, C. E.; Mcgee, J. M.

    1971-01-01

    The Apollo 13 anomaly provided considerable impetus for a variety of types of cryogenic and ignition tests. The logic of the various test program designs, the test techniques, and their final impact upon the investigation findings are described. In addition, several test programs initiated to determine the thermal performance and general performance characteristics of the redesigned Apollo 14 cryogenic storage system are presented.

  8. Effects of Seated Postural Stability and Trunk and Upper Extremity Strength on Performance during Manual Wheelchair Propulsion Tests in Individuals with Spinal Cord Injury: An Exploratory Study

    PubMed Central

    Roy, Audrey; Gabison, Sharon; Verrier, Molly C.

    2016-01-01

    Objectives. To quantify the association between performance-based manual wheelchair propulsion tests (20 m propulsion test, slalom test, and 6 min propulsion test), trunk and upper extremity (U/E) strength, and seated reaching capability and to establish which ones of these variables best predict performance at these tests. Methods. 15 individuals with a spinal cord injury (SCI) performed the three wheelchair propulsion tests prior to discharge from inpatient SCI rehabilitation. Trunk and U/E strength and seated reaching capability with unilateral hand support were also measured. Bivariate correlation and multiple linear regression analyses allowed determining the best determinants and predictors, respectively. Results. The performance at the three tests was moderately or strongly correlated with anterior and lateral flexion trunk strength, anterior seated reaching distance, and the shoulder, elbow, and handgrip strength measures. Shoulder adductor strength-weakest side explained 53% of the variance on the 20-meter propulsion test-maximum velocity. Shoulder adductor strength-strongest side and forward seated reaching distance explained 71% of the variance on the slalom test. Handgrip strength explained 52% of the variance on the 6-minute propulsion test. Conclusion. Performance at the manual wheelchair propulsion tests is explained by a combination of factors that should be considered in rehabilitation. PMID:27635262

  9. Validity of cervical auscultation in the screening for aspiration.

    PubMed

    Al Hawat, A; Woisard, V; Perez-Begout, L; Sarrabère, E; Grand, S; Puech, M

    2014-01-01

    Cervical auscultation could improve the performance of bedside swallowing test to predict aspiration, especially silent aspiration. The aim of this study is to compare the predictive values of bedside swallowing test performed with and without cervical auscultation by logopedist students who had intensive training on cervical auscultation. 64 patients were included in the study. They all underwent swallowing test alone, combined swallowing test and cervical auscultation, and videofluoroscopic swallowing study as defined gold standard. Two logopedist students, at the end of their training, performed the auscultation and noted their results. 128 tests were performed, 96% of the tests were judged positive for aspiration. When comparing the results of the two different clinical tests, the detection of clinical signs is not improved by the addition of auscultation. Using a penetration aspiration scale threshold >5, the area under the curve measured for the swallowing test alone was significantly higher than that measured for the combined tests (p = 0.03) (0.66 for the swallowing test alone (95% CI between 0.49 and 0.83), and 0.50 for the combined tests (95% CI between 0.31 and 0.69). This study showed no advantage in performing cervical auscultation with bedside swallowing test. Cervical auscultation seems to hamper the assessment, mainly the perception of wet voice and laryngeal motion. These results are compatible with literature but need further confirmation using studies performed with trained logopedists.

  10. Oscillating-flow regenerator test rig

    NASA Technical Reports Server (NTRS)

    Wood, J. G.; Gedeon, D. R.

    1994-01-01

    This report summarizes work performed in setting up and performing tests on a regenerator test rig. An earlier status report presented test results, together with heat transfer correlations, for four regenerator samples (two woven screen samples and two felt metal samples). Lessons learned from this testing led to improvements to the experimental setup, mainly instrumentation as well as to the test procedure. Given funding and time constraints for this project it was decided to complete as much testing as possible while the rig was set up and operational, and to forego final data reduction and analysis until later. Additional testing was performed on several of the previously tested samples as well an on five newly fabricated samples. The following report is a summary of the work performed at OU, with many of the final test results included in raw data form.

  11. 40 CFR 60.2690 - How do I conduct the initial and annual performance test?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units Model Rule-Performance Testing...

  12. 40 CFR 60.2690 - How do I conduct the initial and annual performance test?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emissions Guidelines and Compliance Times for Commercial and Industrial Solid Waste Incineration Units Model Rule-Performance Testing...

  13. 42 CFR 493.15 - Laboratories performing waived tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) Pose no reasonable risk of harm to the patient if the test is performed incorrectly. (c) Certificate of... by single analyte instruments with self-contained or component features to perform specimen/reagent...

  14. 42 CFR 493.15 - Laboratories performing waived tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) Pose no reasonable risk of harm to the patient if the test is performed incorrectly. (c) Certificate of... by single analyte instruments with self-contained or component features to perform specimen/reagent...

  15. 42 CFR 493.15 - Laboratories performing waived tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) Pose no reasonable risk of harm to the patient if the test is performed incorrectly. (c) Certificate of... by single analyte instruments with self-contained or component features to perform specimen/reagent...

  16. PDC-bit performance under simulated borehole conditions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, E.E.; Azar, J.J.

    1993-09-01

    Laboratory drilling tests were used to investigate the effects of pressure on polycrystalline-diamond-compact (PDC) drill-bit performance. Catoosa shale core samples were drilled with PDC and roller-cone bits at up to 1,750-psi confining pressure. All tests were conducted in a controlled environment with a full-scale laboratory drilling system. Test results indicate, that under similar operating conditions, increases in confining pressure reduce PDC-bit performance as much as or more than conventional-rock-bit performance. Specific energy calculations indicate that a combination of rock strength, chip hold-down, and bit balling may have reduced performance. Quantifying the degree to which pressure reduces PDC-bit performance will helpmore » researchers interpret test results and improve bit designs and will help drilling engineers run PDC bits more effectively in the field.« less

  17. Parametric performance of circumferentially grooved heat pipes with homogeneous and graded-porosity slab wicks at cryogenic temperatures

    NASA Technical Reports Server (NTRS)

    Groll, M.; Pittman, R. B.; Eninger, J. E.

    1975-01-01

    A recently developed, potentially high-performance nonarterial wick has been extensively tested. This slab wick has an axially varying porosity which can be tailored to match the local stress imposed on the wick. The purpose of the tests was to establish the usefulness of the graded-porosity slab wick at cryogenic temperatures between 110 K and 260 K, with methane and ethane as working fluids. For comparison, a homogeneous (i.e., uniform porosity) slab wick was also tested. The tests included: (1) maximum heat pipe performance as a function of fluid inventory, (2) maximum performance as a function of operating temperature, (3) maximum performance as a function of evaporator elevation, and (4) influence of slab wick orientation on performance. The experimental data was compared with theoretical predictions obtained with the computer program GRADE.

  18. Action versus state orientation and self-control performance after depletion.

    PubMed

    Gröpel, Peter; Baumeister, Roy F; Beckmann, Jürgen

    2014-04-01

    Three studies investigated the role of action versus state orientation in how people deal with depletion of self-control resources. Action-oriented persons were expected to continue allocating resources and hence to perform better than state-oriented persons who were expected to conserve strength. Consistent with this, action-oriented persons performed better on the d2 test of attention than state-oriented persons after a strenuous physical exercise (Study 1), showed higher acuity on the critical fusion frequency test after a test of vigilance (Study 2), and performed better on the Stroop test after a depleting sensorimotor task (Study 3). No differences emerged between action- and state-oriented persons in their initial performance and in a non-depleting context. The impact of depletion on subsequent performance is thus not fixed, but moderated by personality.

  19. Parametric performance of circumferentially grooved heat pipes with homogeneous and graded-porosity slab wicks at cryogenic temperatures. [methane and ethane working fluids

    NASA Technical Reports Server (NTRS)

    Groll, M.; Pittman, R. B.; Eninger, J. E.

    1976-01-01

    A recently developed, potentially high-performance nonarterial wick was extensively tested. This slab wick has an axially varying porosity which can be tailored to match the local stress imposed on the wick. The purpose of the tests was to establish the usefulness of the graded-porosity slab wick at cryogenic temperatures between 110 and 260 K, with methane and ethane as working fluids. For comparison, a homogeneous (i.e., uniform porosity) slab wick was also tested. The tests included: maximum heat pipe performance as a function of fluid inventory, maximum performance as a function of operating temperature, maximum performance as a function of evaporator elevation, and influence of slab wick orientation on performance. The experimental data were compared with theoretical predictions obtained with the GRADE computer program.

  20. Further examination of embedded performance validity indicators for the Conners' Continuous Performance Test and Brief Test of Attention in a large outpatient clinical sample.

    PubMed

    Sharland, Michael J; Waring, Stephen C; Johnson, Brian P; Taran, Allise M; Rusin, Travis A; Pattock, Andrew M; Palcher, Jeanette A

    2018-01-01

    Assessing test performance validity is a standard clinical practice and although studies have examined the utility of cognitive/memory measures, few have examined attention measures as indicators of performance validity beyond the Reliable Digit Span. The current study further investigates the classification probability of embedded Performance Validity Tests (PVTs) within the Brief Test of Attention (BTA) and the Conners' Continuous Performance Test (CPT-II), in a large clinical sample. This was a retrospective study of 615 patients consecutively referred for comprehensive outpatient neuropsychological evaluation. Non-credible performance was defined two ways: failure on one or more PVTs and failure on two or more PVTs. Classification probability of the BTA and CPT-II into non-credible groups was assessed. Sensitivity, specificity, positive predictive value, and negative predictive value were derived to identify clinically relevant cut-off scores. When using failure on two or more PVTs as the indicator for non-credible responding compared to failure on one or more PVTs, highest classification probability, or area under the curve (AUC), was achieved by the BTA (AUC = .87 vs. .79). CPT-II Omission, Commission, and Total Errors exhibited higher classification probability as well. Overall, these findings corroborate previous findings, extending them to a large clinical sample. BTA and CPT-II are useful embedded performance validity indicators within a clinical battery but should not be used in isolation without other performance validity indicators.

  1. Performance characteristics of LOX-H2, tangential-entry, swirl-coaxial, rocket injectors

    NASA Technical Reports Server (NTRS)

    Howell, Doug; Petersen, Eric; Clark, Jim

    1993-01-01

    Development of a high performing swirl-coaxial injector requires an understanding of fundamental performance characteristics. This paper addresses the findings of studies on cold flow atomic characterizations which provided information on the influence of fluid properties and element operating conditions on the produced droplet sprays. These findings are applied to actual rocket conditions. The performance characteristics of swirl-coaxial injection elements under multi-element hot-fire conditions were obtained by analysis of combustion performance data from three separate test series. The injection elements are described and test results are analyzed using multi-variable linear regression. A direct comparison of test results indicated that reduced fuel injection velocity improved injection element performance through improved propellant mixing.

  2. A generalized correlation of experimental flat-plate collector performance. [solar collectors, performance tests, energy policy

    NASA Technical Reports Server (NTRS)

    Simon, F. F.; Miller, D. R.

    1975-01-01

    A generalized collector performance correlation was derived and shown by experimental verification to be of the proper form to account for the majority of the variable conditions encountered both in outdoor and in indoor collector tests. This correlation permits a determination of collector parameters which are essentially nonvarying under conditions which do vary randomly (outdoors) or conditions which vary in a controlled manner (indoors - simulator). It was shown that correlation of the experimental performance of collectors allows the following: (1) comparisons of different collector designs; (2) collector performance prediction under conditions that differ from the conditions of the test program; and (3) monitoring performance degradation effects.

  3. Children and adolescents' performance on a medium-length/nonsemantic word-list test.

    PubMed

    Flores-Lázaro, Julio César; Salgado Soruco, María Alejandra; Stepanov, Igor I

    2017-01-01

    Word-list learning tasks are among the most important and frequently used tests for declarative memory evaluation. For example, the California Verbal Learning Test-Children's Version (CVLT-C) and Rey Auditory Verbal Learning Test provide important information about different cognitive-neuropsychological processes. However, the impact of test length (i.e., number of words) and semantic organization (i.e., type of words) on children's and adolescents' memory performance remains to be clarified, especially during this developmental stage. To explore whether a medium-length non-semantically organized test can produce the typical curvilinear performance that semantically organized tests produce, reflecting executive control, we studied and compared the cognitive performance of normal children and adolescents by utilizing mathematical modeling. The model is based on the first-order system transfer function and has been successfully applied to learning curves for the CVLT-C (15 words, semantically organized paradigm). Results indicate that learning nine semantically unrelated words produces typical curvilinear (executive function) performance in children and younger adolescents and that performance could be effectively analyzed with the mathematical model. This indicates that the exponential increase (curvilinear performance) of correctly learned words does not solely depend on semantic and/or length features. This type of test controls semantic and length effects and may represent complementary tools for executive function evaluation in clinical populations in which semantic and/or length processing are affected.

  4. Yo-Yo IR1 vs. incremental continuous running test for prediction of 3000-m performance.

    PubMed

    Schmitz, Boris; Klose, Andreas; Schelleckes, Katrin; Jekat, Charlotte M; Krüger, Michael; Brand, Stefan-Martin

    2017-11-01

    This study aimed to compare physiological responses during the Yo-Yo intermittent recovery level 1 (Yo-Yo IR1) Test and an incremental continuous running field Test (ICRT) and to analyze their predictive value on 3000-m running performance. Forty moderately trained individuals (18 females) performed the ICRT and Yo-Yo IR1 Test to exhaustion. The ICRT was performed as graded running test with an increase of 2.0 km·h-1 after each 3 min interval for lactate diagnostic. In both tests, blood lactate levels were determined after the test and at 2 and 5 min of recovery. Heart rate (HR) was recorded to monitor differences in HR slopes and HR recovery. Comparison revealed a correlation between ICRT and Yo-Yo IR1 Test performance (R2=0.83, P<0.001), while significant differences in HRmax existed (Yo-Yo IR1, 189±10 bpm; ICRT, 195±16 bpm; P<0.005; ES=0.5). Maximum lactate levels were also different between test (Yo-Yo IR1, 10.1±2.1 mmol∙L-1; ICRT, 11.7±2.4 mmol∙L-1; P<0.01; ES=0.7). Significant inverse correlations were found between the Yo-Yo IR1 Test performance and 3000 m running time (R2=0.77, P<0.0001) as well as the ICRT and 3000 m time (R2=0.90, P<0.0001). Our data suggest that ICRT and Yo-Yo IR1 test are useful field test methods for the prediction of competitive running performances such as 3000-m runs but maximum HR and blood lactate values differ significantly. The ICRT may have higher predictive power for middle- to long- distance running performance such as 3000-m runs offering a reliable test for coaches in the recruitment of athletes or supervision of training concepts.

  5. Performing a Large-Scale Modal Test on the B2 Stand Crane at NASA's Stennis Space Center

    NASA Technical Reports Server (NTRS)

    Stasiunas, Eric C.; Parks, Russel A.; Sontag, Brendan D.

    2018-01-01

    A modal test of NASA's Space Launch System (SLS) Core Stage is scheduled to occur at the Stennis Space Center B2 test stand. A derrick crane with a 150-ft long boom, located at the top of the stand, will be used to suspend the Core Stage in order to achieve defined boundary conditions. During this suspended modal test, it is expected that dynamic coupling will occur between the crane and the Core Stage. Therefore, a separate modal test was performed on the B2 crane itself, in order to evaluate the varying dynamic characteristics and correlate math models of the crane. Performing a modal test on such a massive structure was challenging and required creative test setup and procedures, including implementing both AC and DC accelerometers, and performing both classical hammer and operational modal analysis. This paper describes the logistics required to perform this large-scale test, as well as details of the test setup, the modal test methods used, and an overview and application of the results.

  6. Exploration of task performance tests in a physics laboratory

    NASA Astrophysics Data System (ADS)

    Liu, Dan; El Turkey, Houssein

    2017-11-01

    In this article, we investigate the implementation of task performance tests in an undergraduate physics laboratory. Two performance tests were carried out over two semesters using the task of building a DC circuit. The first implementation in Spring 2014 had certain concerns such as the privacy of students’ testing and their ‘trial and error’ attempts. These concerns were addressed in Fall 2015 through implementing a second performance test. The second implementation was administered differently but the content of the two tests was the same. We discuss the validity of both implementations and present the correlation (or lack of) between the time that students needed to complete the tests and their grades from a paper-based laboratory assessment method.

  7. Nitrate supplementation improves physical performance specifically in non-athletes during prolonged open-ended tests: a systematic review and meta-analysis.

    PubMed

    Campos, Helton O; Drummond, Lucas R; Rodrigues, Quezia T; Machado, Frederico S M; Pires, Washington; Wanner, Samuel P; Coimbra, Cândido C

    2018-03-01

    Nitrate (NO3 -) is an ergogenic nutritional supplement that is widely used to improve physical performance. However, the effectiveness of NO3 - supplementation has not been systematically investigated in individuals with different physical fitness levels. The present study analysed whether different fitness levels (non-athletes v. athletes or classification of performance levels), duration of the test used to measure performance (short v. long duration) and the test protocol (time trials v. open-ended tests v. graded-exercise tests) influence the effects of NO3 - supplementation on performance. This systematic review and meta-analysis was conducted and reported according to the guidelines outlined in the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) statement. A systematic search of electronic databases, including PubMed, Web of Science, SPORTDiscus and ProQuest, was performed in August 2017. On the basis of the search and inclusion criteria, fifty-four and fifty-three placebo-controlled studies evaluating the effects of NO3 - supplementation on performance in humans were included in the systematic review and meta-analysis, respectively. NO3 - supplementation was ergogenic in non-athletes (mean effect size (ES) 0·25; 95 % CI 0·11, 0·38), particularly in evaluations of performance using long-duration open-ended tests (ES 0·47; 95 % CI 0·23, 0·71). In contrast, NO3 - supplementation did not enhance the performance of athletes (ES 0·04; 95 % CI -0·05, 0·15). After objectively classifying the participants into different performance levels, the frequency of trials showing ergogenic effects in individuals classified at lower levels was higher than that in individuals classified at higher levels. Thus, the present study indicates that dietary NO3 - supplementation improves physical performance in non-athletes, particularly during long-duration open-ended tests.

  8. Performance of Healthy Braced Participants During Aerobic and Anaerobic Capacity Tasks

    PubMed Central

    Rishiraj, Neetu; Taunton, Jack E.; Niven, Brian; Lloyd-Smith, Robert; Regan, William; Woollard, Robert

    2011-01-01

    Context: Knee braces were introduced in sports approximately 30 years ago. However, the effects of a functional knee brace (FKB) on aerobic and anaerobic performance after fatigue are unknown. Objective: To investigate whether FKB use in noninjured participants hindered performance during aerobic (Léger beep test) and anaerobic (repeated high-intensity shuttle test [RHIST]) tasks. Design: Crossover study. Setting: Laboratory. Patients or Other Participants: Twenty-seven healthy male provincial and national basketball and field hockey athletes (age = 19.4 ± 3.0 years, range, 17–26 years; height = 182.6 ± 6.8 cm, range, 168–196 cm; mass = 80.0 ± 9.1 kg, range, 66–108 kg). Interventions : Each participant was provided a custom-fitted FKB and performed 5 nonbraced (NBR) testing sessions over 3 days, followed by 5 braced (BR) testing sessions over 3 days, for a total of 17.5 hours of testing per condition. During each testing session, participants performed 1 trial of the Léger beep test and 1 trial of the RHIST in each condition. Main Outcome Measure(s): Predicted maximal oxygen consumption (V˙o2max) and time performance measures were recorded for each NBR and BR trial. Results: Initial performance levels were lower for BR than NBR for both the Léger beep test (BR = 44.3 mL/kg/min, NBR = 47.3 mL/kg/min; F1,26 = 8.726; P = .007) and the RHIST (BR = 16.5 seconds, NBR = 16.2 seconds; F1,26 = 13.98, P = .001). However, with continued FKB use, the aerobic performance measure remained higher for only the first 2 BR testing sessions (NBR = 46.9 mL/kg/min, BR = 42.4 mL/kg/min; F3.0,79.8 = 4.95, P = .003). For the anaerobic test, no performance difference was noted between the testing conditions (NBR = 16.2 seconds, BR = 16.4 seconds; P = .7), whereas fatigue levels were lower during BR testing sessions (NBR = 33%, BR = 31%). After 14.0 hours of FKB use, performance levels were almost equal between the testing conditions (NBR = 47.6 mL/kg/min, BR = 46.1 mL/kg/min). Conclusions: We found an initial decrement in performance when the FKB was used during an aerobic or anaerobic task. However, after 14.0 hours of FKB use, accommodation to the FKB was possible. PMID:21944071

  9. Development of a grinding-specific performance test set-up.

    PubMed

    Olesen, C G; Larsen, B H; Andresen, E L; de Zee, M

    2015-01-01

    The aim of this study was to develop a performance test set-up for America's Cup grinders. The test set-up had to mimic the on-boat grinding activity and be capable of collecting data for analysis and evaluation of grinding performance. This study included a literature-based analysis of grinding demands and a test protocol developed to accommodate the necessary physiological loads. This study resulted in a test protocol consisting of 10 intervals of 20 revolutions each interspersed with active resting periods of 50 s. The 20 revolutions are a combination of both forward and backward grinding and an exponentially rising resistance. A custom-made grinding ergometer was developed with computer-controlled resistance and capable of collecting data during the test. The data collected can be used to find measures of grinding performance such as peak power, time to complete and the decline in repeated grinding performance.

  10. Performance Evaluation of a Data Validation System

    NASA Technical Reports Server (NTRS)

    Wong, Edmond (Technical Monitor); Sowers, T. Shane; Santi, L. Michael; Bickford, Randall L.

    2005-01-01

    Online data validation is a performance-enhancing component of modern control and health management systems. It is essential that performance of the data validation system be verified prior to its use in a control and health management system. A new Data Qualification and Validation (DQV) Test-bed application was developed to provide a systematic test environment for this performance verification. The DQV Test-bed was used to evaluate a model-based data validation package known as the Data Quality Validation Studio (DQVS). DQVS was employed as the primary data validation component of a rocket engine health management (EHM) system developed under NASA's NGLT (Next Generation Launch Technology) program. In this paper, the DQVS and DQV Test-bed software applications are described, and the DQV Test-bed verification procedure for this EHM system application is presented. Test-bed results are summarized and implications for EHM system performance improvements are discussed.

  11. Pharmacy students' test-taking motivation-effort on a low-stakes standardized test.

    PubMed

    Waskiewicz, Rhonda A

    2011-04-11

    To measure third-year pharmacy students' level of motivation while completing the Pharmacy Curriculum Outcomes Assessment (PCOA) administered as a low-stakes test to better understand use of the PCOA as a measure of student content knowledge. Student motivation was manipulated through an incentive (ie, personal letter from the dean) and a process of statistical motivation filtering. Data were analyzed to determine any differences between the experimental and control groups in PCOA test performance, motivation to perform well, and test performance after filtering for low motivation-effort. Incentivizing students diminished the need for filtering PCOA scores for low effort. Where filtering was used, performance scores improved, providing a more realistic measure of aggregate student performance. To ensure that PCOA scores are an accurate reflection of student knowledge, incentivizing and/or filtering for low motivation-effort among pharmacy students should be considered fundamental best practice when the PCOA is administered as a low-stakes test.

  12. Effect of Propellant Flowrate and Purity on Carbon Deposition in LO2/Methane Gas Generators

    NASA Technical Reports Server (NTRS)

    Bossard, J. A.; Burkhardt, W. M.; Niiya, K. Y.; Braam, F.

    1989-01-01

    The generation and deposition of carbon was studied in the Carbon Deposition Program using subscale hardware with LO2/Liquid Natural Gas (LNG) and LO2/Methane propellants at low mixture ratios. The purpose of the testing was to evaluate the effect of methane purity and full scale injection density on carbon deposition. The LO2/LNG gas generator/preburner testing was performed at mixture ratios between 0.24 and 0.58 and chamber pressures from 5.8 to 9.4 MPa (840 to 1370 psia). A total of seven 200 second duration tests were performed. The LNG testing occurred at low injection densities, similar to the previous LO2/RP-1, LO2/propane, and LO2/methane testing performed on the carbon deposition program. The current LO2/methane test series occurred at an injection density factor of approximately 10 times higher than the previous testing. The high injection density LO2/methane testing was performed at mixture ratios between from 0.23 to 0.81 and chamber pressures from 6.4 to 15.2 MPa (925 to 2210 psia). A total of nine high injection density tests were performed. The testing performed demonstrated that low purity methane (LNG) did not produce any detectable change in carbon deposition when compared to pure methane. In addition, the C* performance and the combustion gas temperatures measured were similar to those obtained for pure methane. Similar results were obtained testing pure methane at higher propellant injection densities with coarse injector elements.

  13. Association between fully automated MRI-based volumetry of different brain regions and neuropsychological test performance in patients with amnestic mild cognitive impairment and Alzheimer's disease.

    PubMed

    Arlt, Sönke; Buchert, Ralph; Spies, Lothar; Eichenlaub, Martin; Lehmbeck, Jan T; Jahn, Holger

    2013-06-01

    Fully automated magnetic resonance imaging (MRI)-based volumetry may serve as biomarker for the diagnosis in patients with mild cognitive impairment (MCI) or dementia. We aimed at investigating the relation between fully automated MRI-based volumetric measures and neuropsychological test performance in amnestic MCI and patients with mild dementia due to Alzheimer's disease (AD) in a cross-sectional and longitudinal study. In order to assess a possible prognostic value of fully automated MRI-based volumetry for future cognitive performance, the rate of change of neuropsychological test performance over time was also tested for its correlation with fully automated MRI-based volumetry at baseline. In 50 subjects, 18 with amnestic MCI, 21 with mild AD, and 11 controls, neuropsychological testing and T1-weighted MRI were performed at baseline and at a mean follow-up interval of 2.1 ± 0.5 years (n = 19). Fully automated MRI volumetry of the grey matter volume (GMV) was performed using a combined stereotactic normalisation and segmentation approach as provided by SPM8 and a set of pre-defined binary lobe masks. Left and right hippocampus masks were derived from probabilistic cytoarchitectonic maps. Volumes of the inner and outer liquor space were also determined automatically from the MRI. Pearson's test was used for the correlation analyses. Left hippocampal GMV was significantly correlated with performance in memory tasks, and left temporal GMV was related to performance in language tasks. Bilateral frontal, parietal and occipital GMVs were correlated to performance in neuropsychological tests comprising multiple domains. Rate of GMV change in the left hippocampus was correlated with decline of performance in the Boston Naming Test (BNT), Mini-Mental Status Examination, and trail making test B (TMT-B). The decrease of BNT and TMT-A performance over time correlated with the loss of grey matter in multiple brain regions. We conclude that fully automated MRI-based volumetry allows detection of regional grey matter volume loss that correlates with neuropsychological performance in patients with amnestic MCI or mild AD. Because of the high level of automation, MRI-based volumetry may easily be integrated into clinical routine to complement the current diagnostic procedure.

  14. Classifying performance impairment in response to sleep loss using pattern recognition algorithms on single session testing

    PubMed Central

    St. Hilaire, Melissa A.; Sullivan, Jason P.; Anderson, Clare; Cohen, Daniel A.; Barger, Laura K.; Lockley, Steven W.; Klerman, Elizabeth B.

    2012-01-01

    There is currently no “gold standard” marker of cognitive performance impairment resulting from sleep loss. We utilized pattern recognition algorithms to determine which features of data collected under controlled laboratory conditions could most reliably identify cognitive performance impairment in response to sleep loss using data from only one testing session, such as would occur in the “real world” or field conditions. A training set for testing the pattern recognition algorithms was developed using objective Psychomotor Vigilance Task (PVT) and subjective Karolinska Sleepiness Scale (KSS) data collected from laboratory studies during which subjects were sleep deprived for 26 – 52 hours. The algorithm was then tested in data from both laboratory and field experiments. The pattern recognition algorithm was able to identify performance impairment with a single testing session in individuals studied under laboratory conditions using PVT, KSS, length of time awake and time of day information with sensitivity and specificity as high as 82%. When this algorithm was tested on data collected under real-world conditions from individuals whose data were not in the training set, accuracy of predictions for individuals categorized with low performance impairment were as high as 98%. Predictions for medium and severe performance impairment were less accurate. We conclude that pattern recognition algorithms may be a promising method for identifying performance impairment in individuals using only current information about the individual’s behavior. Single testing features (e.g., number of PVT lapses) with high correlation with performance impairment in the laboratory setting may not be the best indicators of performance impairment under real-world conditions. Pattern recognition algorithms should be further tested for their ability to be used in conjunction with other assessments of sleepiness in real-world conditions to quantify performance impairment in response to sleep loss. PMID:22959616

  15. Visual determinants of reduced performance on the Stroop color-word test in normal aging individuals.

    PubMed

    van Boxtel, M P; ten Tusscher, M P; Metsemakers, J F; Willems, B; Jolles, J

    2001-10-01

    It is unknown to what extent the performance on the Stroop color-word test is affected by reduced visual function in older individuals. We tested the impact of common deficiencies in visual function (reduced distant and close acuity, reduced contrast sensitivity, and color weakness) on Stroop performance among 821 normal individuals aged 53 and older. After adjustment for age, sex, and educational level, low contrast sensitivity was associated with more time needed on card I (word naming), red/green color weakness with slower card 2 performance (color naming), and reduced distant acuity with slower performance on card 3 (interference). Half of the age-related variance in speed performance was shared with visual function. The actual impact of reduced visual function may be underestimated in this study when some of this age-related variance in Stroop performance is mediated by visual function decrements. It is suggested that reduced visual function has differential effects on Stroop performance which need to be accounted for when the Stroop test is used both in research and in clinical settings. Stroop performance measured from older individuals with unknown visual status should be interpreted with caution.

  16. Updating and Not Shifting Predicts Learning Performance in Young and Middle-Aged Adults

    ERIC Educational Resources Information Center

    Gijselaers, Hieronymus J. M.; Meijs, Celeste; Neroni, Joyce; Kirschner, Paul A.; de Groot, Renate H. M.

    2017-01-01

    The goal of this study was to investigate whether single executive function (EF) tests were predictive for learning performance in mainly young and middle-aged adults. The tests measured shifting and updating. Processing speed was also measured. In an observational study, cognitive performance and learning performance were measured objectively in…

  17. Microgravity effects on standardized cognitive performance measures

    NASA Technical Reports Server (NTRS)

    Schiflett, Samuel G.

    1992-01-01

    The purpose of this experiment, selected to fly on the International Microgravity Laboratory (IML-2) Spacelab mission, is to determine the effects of microgravity upon the cognitive skills which are critical to successful performance of many tasks on board the Space Shuttle. Six tests from the Unified Tri-service Cognitive Performance Assessment Battery (UTC-PAB) will be administered to the Mission Specialists to fulfill the goals of this experiment. These tests are based upon current theoretical models of human performance and the hypothesized effects of microgravity. The principle objective is the identification of the effects of microgravity upon specific information processing skills affecting performance from those of fatigue and shifts in work/rest cycles. Multiple measures of both short and long term fatigue will be obtained and used as a major independent variable for the analysis of these performance data. Scientific supporting studies will determine optimum practice and performance testing schedules for the astronauts. The same tests will be used post-flight to collect data on the recovery of any cognitive performance impairment compared with pre-flight, baseline levels.

  18. Can more than one incremental cycling test be performed within one day?

    PubMed

    Scharhag-Rosenberger, Friederike; Carlsohn, Anja; Lundby, Carsten; Schüler, Stefan; Mayer, Frank; Scharhag, Jürgen

    2014-01-01

    Changes in performance parameters over four consecutive maximal incremental cycling tests were investigated to determine how many tests can be performed within one single day without negatively affecting performance. Sixteen male and female subjects (eight trained (T): 25 ± 3 yr, BMI 22.6 ± 2.5 kg·m(-2), maximal power output (P(max)) 4.6 ± 0.5 W·kg(-1); eight untrained (UT): 27 ± 3 yr, BMI 22.3 ± 1.2 kg·m(-2), P(max) 2.9 ± 0.3 W·kg(-1)) performed four successive maximal incremental cycling tests separated by 1.5 h of passive rest. Individual energy requirements were covered by standardised meals between trials. Maximal oxygen uptake (VO(2max)) remained unchanged over the four tests in both groups (P = 0.20 and P = 0.33, respectively). P(max) did not change in the T group (P = 0.32), but decreased from the third test in the UT group (P < 0.01). Heart rate responses to submaximal exercise were elevated from the third test in the T group and from the second test in the UT group (P < 0.05). The increase in blood lactate shifted rightward over the four tests in both groups (P < 0.001 and P < 0.01, respectively). Exercise-induced net increases in epinephrine and norepinephrine were not different between the tests in either group (P ≥ 0.15). If VO(2max) is the main parameter of interest, trained and untrained individuals can perform at least four maximal incremental cycling tests per day. However, because other parameters changed after the first and second test, respectively, no more than one test per day should be performed if parameters other than VO(2max) are the prime focus.

  19. Flight tests for the assessment of task performance and control activity

    NASA Technical Reports Server (NTRS)

    Pausder, H. J.; Hummes, D.

    1982-01-01

    The tests were performed with the helicopters BO 105 and UH-1D. Closely connected with tactical demands the six test pilots' task was to minimize the time and the altitude over the obstacles. The data reduction yields statistical evaluation parameters describing the control activity of the pilots and the achieved task performance. The results are shown in form of evaluation diagrams. Additionally dolphin tests with varied control strategy were performed to get more insight into the influence of control techniques. From these test results recommendations can be derived to emphasize the direct force control and to reduce the collective to pitch crosscoupling for the dolphin.

  20. A Novel Lithium-ion Laminated Pouch Cell Tested For Performance And Safety

    NASA Technical Reports Server (NTRS)

    Jeevarajan, Judith A.; Inoue, Takefumi

    2006-01-01

    A new Li-ion 4.0 Ah pouch cell from GS Yuasa has been tested to determine its performance and safety. The cell is of a laminate pouch design with liquid electrolyte. The rate, thermal and vacuum performance capabilities have been tested to determine the optimum parameters. Under vacuum conditions, the cells were cycled under restrained and unrestrained configurations. The burst pressure of the laminate pouch was also determined. The overcharge, overdischarge into reversal and external short circuit safety tests were also performed to determine the cell s tolerance to abuse. Key Words: Li-ion, safety, vacuum test, abuse, COTS batteries, rate capability

  1. Stereotype threat in classroom settings: the interactive effect of domain identification, task difficulty and stereotype threat on female students' maths performance.

    PubMed

    Keller, Johannes

    2007-06-01

    Stereotype threat research revealed that negative stereotypes can disrupt the performance of persons targeted by such stereotypes. This paper contributes to stereotype threat research by providing evidence that domain identification and the difficulty level of test items moderate stereotype threat effects on female students' maths performance. The study was designed to test theoretical ideas derived from stereotype threat theory and assumptions outlined in the Yerkes-Dodson law proposing a nonlinear relationship between arousal, task difficulty and performance. Participants were 108 high school students attending secondary schools. Participants worked on a test comprising maths problems of different difficulty levels. Half of the participants learned that the test had been shown to produce gender differences (stereotype threat). The other half learned that the test had been shown not to produce gender differences (no threat). The degree to which participants identify with the domain of maths was included as a quasi-experimental factor. Maths-identified female students showed performance decrements under conditions of stereotype threat. Moreover, the stereotype threat manipulation had different effects on low and high domain identifiers' performance depending on test item difficulty. On difficult items, low identifiers showed higher performance under threat (vs. no threat) whereas the reverse was true in high identifiers. This interaction effect did not emerge on easy items. Domain identification and test item difficulty are two important factors that need to be considered in the attempt to understand the impact of stereotype threat on performance.

  2. Microsurgical Performance After Sleep Interruption: A NeuroTouch Simulator Study.

    PubMed

    Micko, Alexander; Knopp, Karoline; Knosp, Engelbert; Wolfsberger, Stefan

    2017-10-01

    In times of the ubiquitous debate about doctors' working hour restrictions, it is still questionable if the physician's performance is impaired by high work load and long shifts. In this study, we evaluated the impact of sleep interruption on neurosurgical performance. Ten medical students and 10 neurosurgical residents were tested on the virtual-reality simulator NeuroTouch by performing an identical microsurgical task, well rested (baseline test), and after sleep interruption at night (stress test). Deviation of total score, timing, and excessive force on tissue were evaluated. In addition, vital parameters and self-assessment were analyzed. After sleep interruption, total performance score increased significantly (45.1 vs. 48.7, baseline vs. stress test, P = 0.048) while timing remained stable (10.1 vs. 10.4 minutes for baseline vs. stress test, P > 0.05) for both students and residents. Excessive force decreased in both groups during the stress test for the nondominant hand (P = 0.05). For the dominant hand, an increase of excessive force was encountered in the group of residents (P = 0.05). In contrast to their results, participants of both groups assessed their performance worse during the stress test. In our study, we found an increase of neurosurgical simulator performance in neurosurgical residents and medical students under simulated night shift conditions. Further, microsurgical dexterity remained unchanged. Based on our results and the data in the available literature, we cannot confirm that working hour restrictions will have a positive effect on neurosurgical performance. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Maximal and submaximal endurance performance in adults with severe haemophilia.

    PubMed

    Herbsleb, M; Hilberg, T

    2009-01-01

    Maximal exercise testing, including the determination of maximal performance and maximal oxygen uptake (VO(2max)), is considered the gold standard for assessing maximal endurance performance. The effectiveness of such testing is often reduced in haemophilic adults owing to musculoskeletal impairments or pain rather than because of cardiac exertion. The measurement of submaximal performance parameters overcomes many limitations of maximal exercise testing but a testing standard is still lacking. The aim of this study was to investigate maximal and particularly submaximal endurance performance of adult patients with severe haemophilia A and B. Eleven patients and 11 matched healthy controls were tested by spiroergometry with a specific treadmill test and the power was calculated in Watts. The haemophilic group achieved lower absolute (210 +/- 63 W) and weight-related (2.94 +/- 0.98 W kg(-1)) maximal endurance performance compared with the control group (287 +/- 50 W resp. 3.82 +/- 0.53 W kg(-1); P

  4. Acoustic and Thermal Testing of an Integrated Multilayer Insulation and Broad Area Cooling Shield System

    NASA Technical Reports Server (NTRS)

    Wood, Jessica J.; Foster, Lee W.

    2013-01-01

    A Multilayer Insulation (MLI) and Broad Area Cooling (BAC) shield thermal control system shows promise for long-duration storage of cryogenic propellant. The NASA Cryogenic Propellant Storage and Transfer (CPST) project is investigating the thermal and structural performance of this tank-applied integrated system. The MLI/BAC Shield Acoustic and Thermal Test was performed to evaluate the MLI/BAC shield's structural performance by subjecting it to worst-case launch acoustic loads. Identical thermal tests using Liquid Nitrogen (LN2) were performed before and after the acoustic test. The data from these tests was compared to determine if any degradation occurred in the thermal performance of the system as a result of exposure to the acoustic loads. The thermal test series consisted of two primary components: a passive boil-off test to evaluate the MLI performance and an active cooling test to evaluate the integrated MLI/BAC shield system with chilled vapor circulating through the BAC shield tubes. The acoustic test used loads closely matching the worst-case envelope of all launch vehicles currently under consideration for CPST. Acoustic test results yielded reasonable responses for the given load. The thermal test matrix was completed prior to the acoustic test and successfully repeated after the acoustic test. Data was compared and yielded near identical results, indicating that the MLI/BAC shield configuration tested in this series is an option for structurally implementing this thermal control system concept.

  5. Performance of a distributed superscalar storage server

    NASA Technical Reports Server (NTRS)

    Finestead, Arlan; Yeager, Nancy

    1993-01-01

    The RS/6000 performed well in our test environment. The potential exists for the RS/6000 to act as a departmental server for a small number of users, rather than as a high speed archival server. Multiple UniTree Disk Server's utilizing one UniTree Disk Server's utilizing one UniTree Name Server could be developed that would allow for a cost effective archival system. Our performance tests were clearly limited by the network bandwidth. The performance gathered by the LibUnix testing shows that UniTree is capable of exceeding ethernet speeds on an RS/6000 Model 550. The performance of FTP might be significantly faster if asked to perform across a higher bandwidth network. The UniTree Name Server also showed signs of being a potential bottleneck. UniTree sites that would require a high ratio of file creations and deletions to reads and writes would run into this bottleneck. It is possible to improve the UniTree Name Server performance by bypassing the UniTree LibUnix Library altogether and communicating directly with the UniTree Name Server and optimizing creations. Although testing was performed in a less than ideal environment, hopefully the performance statistics stated in this paper will give end-users a realistic idea as to what performance they can expect in this type of setup.

  6. Relationships Among Two Repeated Activity Tests and Aerobic Fitness of Volleyball Players.

    PubMed

    Meckel, Yoav; May-Rom, Moran; Ekshtien, Aya; Eisenstein, Tamir; Nemet, Dan; Eliakim, Alon

    2015-08-01

    The purpose of the study was to determine performance indices of a repeated sprint test (RST) and to examine their relationships with performance indices of a repeated jump test (RJT) and with aerobic fitness among trained volleyball players. Sixteen male volleyball players performed RST (6 × 30 m sprints), RJT (6 sets of 6 consecutive jumps), and an aerobic power test (20-m Shuttle Run Test). Performance indices for the RST and the RJT were (a) the ideal 30-m run time (IS), the total run time (TS) of the 6 sprints, and the performance decrement (PD) during the test and (b) the ideal jump height (IJ), the total jump height (TJ) of all the jumps, and the PD during the test, respectively. No significant correlations were found between performance indices of the RST and RJT. Significant correlations were found between PD, IS, and TS in the RST protocol and predicted peak V[Combining Dot Above]O2 (r = -0.60, -0.75, -0.77, respectively). No significant correlations were found between performance indices of the RJT (IJ, TJ, and PD) and peak V[Combining Dot Above]O2. The findings suggest that a selection of repeated activity test protocols should acknowledge the specific technique used in the sport, and that a distinct RJT, rather than the classic RST, is more appropriate for assessing the anaerobic capabilities of volleyball players. The findings also suggest that aerobic fitness plays only a minor role in performance maintenance throughout characteristic repeated jumping activity of a volleyball game.

  7. Ankle taping does not impair performance in jump or balance tests.

    PubMed

    Abián-Vicén, Javier; Alegre, Luis M; Fernández-Rodríguez, J Manuel; Lara, Amador J; Meana, Marta; Aguado, Xavier

    2008-01-01

    This study aimed to investigate the influence of prophylactic ankle taping on two balance tests (static and dynamic balance) and one jump test, in the push off and the landing phase. Fifteen active young subjects (age: 21.0 ± 4.4 years) without previous ankle injuries volunteered for the study. Each participant performed three tests in two different situations: with taping and without taping. The tests were a counter movement jump, static balance, and a dynamic posturography test. The tests and conditions were randomly performed. The path of the center of pressures was measured in the balance tests, and the vertical ground reaction forces were recorded during the push-off and landing phases of the counter movement jump. Ankle taping had no influence on balance performance or in the push off phase of the jump. However, the second peak vertical force value during the landing phase of the jump was 12% greater with ankle taping (0.66 BW, 95% CI -0.64 to 1.96). The use of prophylactic ankle taping had no influence on the balance or jump performance of healthy young subjects. In contrast, the taped ankle increased the second peak vertical force value, which could be related to a greater risk of injury produced by the accumulation of repeated impacts in sports where jumps are frequently performed. Key pointsAnkle taping has no influence on balance performance.Ankle taping does not impair performance during the push-off phase of the jump.Ankle taping could increase the risk of injury during landings by increasing peak forces.

  8. Ankle Taping Does Not Impair Performance in Jump or Balance Tests

    PubMed Central

    Abián-Vicén, Javier; Alegre, Luis M.; Fernández-Rodríguez, J. Manuel; Lara, Amador J.; Meana, Marta; Aguado, Xavier

    2008-01-01

    This study aimed to investigate the influence of prophylactic ankle taping on two balance tests (static and dynamic balance) and one jump test, in the push off and the landing phase. Fifteen active young subjects (age: 21.0 ± 4.4 years) without previous ankle injuries volunteered for the study. Each participant performed three tests in two different situations: with taping and without taping. The tests were a counter movement jump, static balance, and a dynamic posturography test. The tests and conditions were randomly performed. The path of the center of pressures was measured in the balance tests, and the vertical ground reaction forces were recorded during the push-off and landing phases of the counter movement jump. Ankle taping had no influence on balance performance or in the push off phase of the jump. However, the second peak vertical force value during the landing phase of the jump was 12% greater with ankle taping (0.66 BW, 95% CI -0.64 to 1.96). The use of prophylactic ankle taping had no influence on the balance or jump performance of healthy young subjects. In contrast, the taped ankle increased the second peak vertical force value, which could be related to a greater risk of injury produced by the accumulation of repeated impacts in sports where jumps are frequently performed. Key pointsAnkle taping has no influence on balance performance.Ankle taping does not impair performance during the push-off phase of the jump.Ankle taping could increase the risk of injury during landings by increasing peak forces. PMID:24149902

  9. Development and Results of a First Generation Least Expensive Approach to Fission: Module Tests and Results

    NASA Technical Reports Server (NTRS)

    Houts, Mike; Godfroy, Tom; Pederson, Kevin; Sena, J. Tom; VanDyke, Melissa; Dickens, Ricky; Reid, Bob J.; Martin, Jim

    2000-01-01

    The use of resistance heaters to simulate heat from fission allows extensive development of fission systems to be performed in non-nuclear test facilities, saving time and money. Resistance heated tests on the Module Unfueled Thermal-hydraulic Test (MUTT) article has been performed at the Marshall Space Flight Center. This paper discusses the results of these experiments and identifies future tests to be performed.

  10. Wind tunnel performance results of an aeroelastically scaled 2/9 model of the PTA flight test prop-fan

    NASA Technical Reports Server (NTRS)

    Stefko, George L.; Rose, Gayle E.; Podboy, Gary G.

    1987-01-01

    High speed wind tunnel aerodynamic performance tests of the SR-7A advanced prop-fan have been completed in support of the Prop-Fan Test Assessment (PTA) flight test program. The test showed that the SR-7A model performed aerodynamically very well. At the cruise design condition, the SR-7A prop fan had a high measured net efficiency of 79.3 percent.

  11. ESGE-ESGENA technical specification for process validation and routine testing of endoscope reprocessing in washer-disinfectors according to EN ISO 15883, parts 1, 4, and ISO/TS 15883-5.

    PubMed

    Beilenhoff, Ulrike; Biering, Holger; Blum, Reinhard; Brljak, Jadranka; Cimbro, Monica; Dumonceau, Jean-Marc; Hassan, Cesare; Jung, Michael; Neumann, Christiane; Pietsch, Michael; Pineau, Lionel; Ponchon, Thierry; Rejchrt, Stanislav; Rey, Jean-François; Schmidt, Verona; Tillett, Jayne; van Hooft, Jeanin

    2017-12-01

    1 Prerequisites. The clinical service provider should obtain confirmation from the endoscope washer-disinfector (EWD) manufacturer that all endoscopes intended to be used can be reprocessed in the EWD. 2 Installation qualification. This can be performed by different parties but national guidelines should define who has the responsibilities, taking into account legal requirements. 3 Operational qualification. This should include parametric tests to verify that the EWD is working according to its specifications. 4 Performance qualification. Testing of cleaning performance, microbiological testing of routinely used endoscopes, and the quality of the final rinse water should be considered in all local guidelines. The extent of these tests depends on local requirements. According to the results of type testing performed during EWD development, other parameters can be tested if local regulatory authorities accept this. Chemical residues on endoscope surfaces should be searched for, if acceptable test methods are available. 5 Routine inspections. National guidelines should consider both technical and performance criteria. Individual risk analyses performed in the validation and requalification processes are helpful for defining appropriate test frequencies for routine inspections. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Characterization of Louisiana asphalt mixtures using simple performance tests and MEPDG.

    DOT National Transportation Integrated Search

    2014-04-01

    The National Cooperative Highway Research Program (NCHRP) Project 9-19, Superpave Support and Performance : Models Management, recommended three Simple Performance Tests (SPTs) to complement the Superpave volumetric : mixture design method. These are...

  13. Deficits in Attention and Visual Processing but not Global Cognition Predict Simulated Driving Errors in Drivers Diagnosed With Mild Alzheimer's Disease.

    PubMed

    Yamin, Stephanie; Stinchcombe, Arne; Gagnon, Sylvain

    2016-06-01

    This study sought to predict driving performance of drivers with Alzheimer's disease (AD) using measures of attention, visual processing, and global cognition. Simulated driving performance of individuals with mild AD (n = 20) was contrasted with performance of a group of healthy controls (n = 21). Performance on measures of global cognitive function and specific tests of attention and visual processing were examined in relation to simulated driving performance. Strong associations were observed between measures of attention, notably the Test of Everyday Attention (sustained attention; r = -.651, P = .002) and the Useful Field of View (r = .563, P = .010), and driving performance among drivers with mild AD. The Visual Object and Space Perception Test-object was significantly correlated with the occurrence of crashes (r = .652, P = .002). Tests of global cognition did not correlate with simulated driving outcomes. The results suggest that professionals exercise caution when extrapolating driving performance based on global cognitive indicators. © The Author(s) 2015.

  14. The development of a performance-enhancing additive for vapor-compression heat pumps

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grzyll, L.R.; Scaringe, R.P.; Gottschlich, J.M.

    1997-12-31

    This paper describes the testing results of a vapor-compression heat pump operating with HFC-134a refrigerant and a performance-enhancing additive. Preliminary bench-top testing of this additive, when added to polyolester (POE) lubricant and HFC-134a refrigerant, showed surprising enhancements to system COP. To further investigate this finding, the authors designed and fabricated a vapor-compression heat pump test stand for the 3--5 ton range. The authors investigated the effect of different concentrations of this additive on various system performance parameters such as cooling capacity, compressor power requirement, pressure ratio, compressor pressure difference, compressor isentropic efficiency, refrigerant flow rate, and heat exchanger performance. Themore » authors investigated various heat source and heat sink conditions to simulate air-conditioning and heat pump operating conditions. To investigate the effect of this additive on compressor lubrication and life, the authors performed compressor life tests (with scroll and reciprocating compressors), and had lubrication wear tests performed with various concentrations of the additive in the POE lubricant.« less

  15. Individual differences in infant fearfulness and cognitive performance: a testing, performance, or competence effect?

    PubMed

    Rieser-Danner, Loretta A

    2003-02-01

    The author conducted 2 studies to examine the relations between infant fear and cognitive testing performance in 12-month-old infants. In Study 1, fear was assessed by using 2 standard temperament questionnaires and a laboratory-based, standardized stranger approach. Individual differences in cognitive development were assessed using the Object Permanence Scale of the Infant Psychological Development Scales (I. C. Uzgiris & J. M. Hunt, 1975). All 3 assessments of fear significantly predicted object permanence performance, with correlations ranging from -.32 to -.35. In Study 2, fear was assessed via a maternal report questionnaire, and habituation performance was assessed via a basic-level categorization task. Familiarity with the examiner and with the testing environment was manipulated to test for a familiarity influence on performance. Testing revealed individual differences in both fear and habituation. Results suggest that highly fearful infants required more trials to habituate and were less likely to meet the habituation criterion than infants who were less fearful. Methodological and conceptual implications of these results are discussed.

  16. The GRE Subject Test Performance of U.S. and Non-U.S. Examinees, 1982-84: A Comparative Analysis.

    ERIC Educational Resources Information Center

    Wilson, Kenneth M.

    The Graduate Record Examination (GRE) subject-matter achievement tests are offered in 17 fields. This study investigated the performance of U.S. and non-U.S. citizens on the Subject Tests, and the relationship of selected English-proficiency-related background variables to the test performance of non-U.S. citizens. It was also concerned with…

  17. Report on the State of Development, Availability, Evaluation, and Future use of Test Kits for the Measurement of Lead in Paint

    EPA Science Inventory

    The purpose of this issue paper is to address the availability and performance characteristics of portable lead test kits especially suited for lead in paint, procedures for evaluating the performance of these test kits, and the availability of performance evaluation (PE) materia...

  18. Do Content Area Passages Affect Student Performance on Reading Comprehension Tests?

    ERIC Educational Resources Information Center

    Peretz, Arna S.

    A study conducted in Israel investigated the relevance of subject-specific reading passages to performance on reading comprehension tests for advanced university students of English as a second language. The research specifically examined (1) whether students performed better when the reading test content was directly related to their field of…

  19. What's Happening on the School Bus Performance Front?

    ERIC Educational Resources Information Center

    Combs, Hanford L.

    The most urgent order of business in the national scene is to complete the development of a series of new performance tests for school bus bodies and chassis to establish a benchmark for safe construction that can be verified by independent testing agencies. Such performance tests should incorporate the new Federal Joint Strength Efficiency…

  20. 42 CFR 493.25 - Laboratories performing tests of high complexity.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 5 2014-10-01 2014-10-01 false Laboratories performing tests of high complexity. 493.25 Section 493.25 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS General Provisions § 493.25 Laboratories performing tests of high...

  1. 47 CFR 76.1704 - Proof-of-performance test data.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 4 2012-10-01 2012-10-01 false Proof-of-performance test data. 76.1704 Section 76.1704 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Documents to be Maintained for Inspection § 76.1704 Proof-of-performance test data. (a) The proof of...

  2. 47 CFR 76.1704 - Proof-of-performance test data.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 4 2014-10-01 2014-10-01 false Proof-of-performance test data. 76.1704 Section 76.1704 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Documents to be Maintained for Inspection § 76.1704 Proof-of-performance test data. (a) The proof of...

  3. 42 CFR 493.20 - Laboratories performing tests of moderate complexity.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 5 2014-10-01 2014-10-01 false Laboratories performing tests of moderate complexity. 493.20 Section 493.20 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS General Provisions § 493.20 Laboratories performing tests of...

  4. ACT Profile Report: State. Graduating Class 2012. New Hampshire

    ERIC Educational Resources Information Center

    ACT, Inc., 2012

    2012-01-01

    This report provides information about the performance of New Hampshire's 2012 graduating seniors who took the ACT as sophomores, juniors, or seniors; and self-reported at the time of testing that they were scheduled to graduate in 2012 and tested under standard time conditions. This report focuses on: (1) Performance: student test performance in…

  5. Is Cognitive Test-Taking Anxiety Associated With Academic Performance Among Nursing Students?

    PubMed

    Duty, Susan M; Christian, Ladonna; Loftus, Jocelyn; Zappi, Victoria

    2016-01-01

    The cognitive component of test anxiety was correlated with academic performance among nursing students. Modest but statistically significant lower examination grade T scores were observed for students with high compared with low levels of cognitive test anxiety (CTA). High levels of CTA were associated with reduced academic performance.

  6. 40 CFR 60.63 - Monitoring of operations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... § 60.62, you must demonstrate compliance through an initial performance test. You will conduct your performance test using Method 5 or Method 5I at appendix A-3 to part 60 of this chapter. You must also monitor... CPMS, you will establish a site-specific operating limit. If your PM performance test demonstrates your...

  7. 40 CFR 60.63 - Monitoring of operations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... § 60.62, you must demonstrate compliance through an initial performance test. You will conduct your performance test using Method 5 or Method 5I at appendix A-3 to part 60 of this chapter. You must also monitor... CPMS, you will establish a site-specific operating limit. If your PM performance test demonstrates your...

  8. 40 CFR 63.11452 - What are the performance test requirements for new and existing sources?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... production rate for the performance test, kilograms (tons) of glass produced per hour. (v) Calculate the 3... = Average glass production rate for the performance test, kilograms (tons) of glass produced per hour. (v... Glass Manufacturing Area Sources Standards, Compliance, and Monitoring Requirements § 63.11452 What are...

  9. 40 CFR 63.11452 - What are the performance test requirements for new and existing sources?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... production rate for the performance test, kilograms (tons) of glass produced per hour. (v) Calculate the 3... = Average glass production rate for the performance test, kilograms (tons) of glass produced per hour. (v... Glass Manufacturing Area Sources Standards, Compliance, and Monitoring Requirements § 63.11452 What are...

  10. 40 CFR 63.11452 - What are the performance test requirements for new and existing sources?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... production rate for the performance test, kilograms (tons) of glass produced per hour. (v) Calculate the 3... = Average glass production rate for the performance test, kilograms (tons) of glass produced per hour. (v... Glass Manufacturing Area Sources Standards, Compliance, and Monitoring Requirements § 63.11452 What are...

  11. 40 CFR 63.11452 - What are the performance test requirements for new and existing sources?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... production rate for the performance test, kilograms (tons) of glass produced per hour. (v) Calculate the 3... = Average glass production rate for the performance test, kilograms (tons) of glass produced per hour. (v... Glass Manufacturing Area Sources Standards, Compliance, and Monitoring Requirements § 63.11452 What are...

  12. 40 CFR 63.11452 - What are the performance test requirements for new and existing sources?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... production rate for the performance test, kilograms (tons) of glass produced per hour. (v) Calculate the 3... = Average glass production rate for the performance test, kilograms (tons) of glass produced per hour. (v... Glass Manufacturing Area Sources Standards, Compliance, and Monitoring Requirements § 63.11452 What are...

  13. Comparing Student Performance on Paper-and-Pencil and Computer-Based-Tests

    ERIC Educational Resources Information Center

    Hardcastle, Joseph; Herrmann-Abell, Cari F.; DeBoer, George E.

    2017-01-01

    Can student performance on computer-based tests (CBT) and paper-and-pencil tests (PPT) be considered equivalent measures of student knowledge? States and school districts are grappling with this question, and although studies addressing this question are growing, additional research is needed. We report on the performance of students who took…

  14. Predicting Examination Performance Using an Expanded Integrated Hierarchical Model of Test Emotions and Achievement Goals

    ERIC Educational Resources Information Center

    Putwain, Dave; Deveney, Carolyn

    2009-01-01

    The aim of this study was to examine an expanded integrative hierarchical model of test emotions and achievement goal orientations in predicting the examination performance of undergraduate students. Achievement goals were theorised as mediating the relationship between test emotions and performance. 120 undergraduate students completed…

  15. Knox's Cube Imitation Test: A Historical Review and an Experimental Analysis

    ERIC Educational Resources Information Center

    Richardson, John T. E.

    2005-01-01

    The cube imitation test was developed by Knox (1913) as a nonverbal test of intelligence. Many variants show satisfactory reliability, but performance is correlated both with Verbal IQ and with Performance IQ. Performance is impaired by cerebral lesions but unrelated to the side of lesion. Examinees describe both verbal and visuospatial…

  16. Performance Evaluation of the International Space Station Flow Boiling and Condensation Experiment (FBCE) Test Facility

    NASA Technical Reports Server (NTRS)

    Hasan, Mohammad; Balasubramaniam, R.; Nahra, Henry; Mackey, Jeff; Hall, Nancy; Frankenfield, Bruce; Harpster, George; May, Rochelle; Mudawar, Issam; Kharangate, Chirag R.; hide

    2016-01-01

    A ground-based experimental facility to perform flow boiling and condensation experiments is built in support of the development of the long duration Flow Boiling and Condensation Experiment (FBCE) destined for operation on board of the International Space Station (ISS) Fluid Integrated Rack (FIR). We performed tests with the condensation test module oriented horizontally and vertically. Using FC-72 as the test fluid and water as the cooling fluid, we evaluated the operational characteristics of the condensation module and generated ground based data encompassing the range of parameters of interest to the condensation experiment to be performed on the ISS. During this testing, we also evaluated the pressure drop profile across different components of the fluid subsystem, heater performance, on-orbit degassing subsystem, and the heat loss from different components. In this presentation, we discuss representative results of performance testing of the FBCE flow loop. These results will be used in the refinement of the flight system design and build-up of the FBCE which is scheduled for flight in 2019.

  17. Performance Measurement of Advanced Stirling Convertors (ASC-E3)

    NASA Technical Reports Server (NTRS)

    Oriti, Salvatore M.

    2013-01-01

    NASA Glenn Research Center (GRC) has been supporting development of the Advanced Stirling Radioisotope Generator (ASRG) since 2006. A key element of the ASRG project is providing life, reliability, and performance testing data of the Advanced Stirling Convertor (ASC). The latest version of the ASC (ASC-E3, to represent the third cycle of engineering model test hardware) is of a design identical to the forthcoming flight convertors. For this generation of hardware, a joint Sunpower and GRC effort was initiated to improve and standardize the test support hardware. After this effort was completed, the first pair of ASC-E3 units was produced by Sunpower and then delivered to GRC in December 2012. GRC has begun operation of these units. This process included performance verification, which examined the data from various tests to validate the convertor performance to the product specification. Other tests included detailed performance mapping that encompassed the wide range of operating conditions that will exist during a mission. These convertors were then transferred to Lockheed Martin for controller checkout testing. The results of this latest convertor performance verification activity are summarized here.

  18. Test Administrator's Handbook and Student Instructions for Job-Task Performance Tests for Doppler Radar, AN/APN-147 and its Computer AN/ASN-35, and Associated Test Equipment and Hand Tools. Report for June-December 1972.

    ERIC Educational Resources Information Center

    Matrix Research Co., Alexandria, VA.

    The handbook covers a comprehensive series of Job-Task Performance Tests for the Doppler Radar (AN/APN) and its Associated Computer (AN/ASN-35). The test series has been developed to measure job performance of the electronic technician. These tests encompass all phases of day-to-day preventative and corrective maintenance that technicians are…

  19. Quiet Clean Short-haul Experimental Engine (QCSEE) Under-The-Wing (UTW) engine composite nacelle test report. Volume 1: Summary, aerodynamic and mechanical performance

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The performance test results of the final under-the-wing engine configuration are presented. One hundred and six hours of engine operation were completed, including mechanical and performance checkout, baseline acoustic testing with a bellmouth inlet, reverse thrust testing, acoustic technology tests, and limited controls testing. The engine includes a variable pitch fan having advanced composite fan blades and using a ball-spline pitch actuation system.

  20. Test anxiety in medical school is unrelated to academic performance but correlates with an effort/reward imbalance.

    PubMed

    Hahn, Henry; Kropp, Peter; Kirschstein, Timo; Rücker, Gernot; Müller-Hilke, Brigitte

    2017-01-01

    During their early years at medical school, students repeatedly criticize their workload, time constraints and test associated stress. At the same time, depressiveness and anxiety among first and second year medical students are on the rise. We therefore hypothesized that test anxiety may be related to depressiveness and considered cognitive and academic performances as confounders for the former and psychosocial distress for the latter. A whole class of 200 second year students was invited to participate in the study. Anxiety as a trait, depressiveness, crystallized intelligence, verbal fluency and psychosocial distress were assessed using validated tests and questionnaires. Acute state anxiety and sympathetic stress parameters were measured in real life situations immediately before an oral and a written exam and paired tests were used to compare the individual anxieties at the various time points. Previous academic performances were self-reported, the results of the impending exams were monitored. Finally, correlations were performed to test for interrelatedness between academic performances and the various personal, cognitive and psychosocial factors. Acute test anxiety did not correlate with depressiveness nor did it correlate with previous nor impending academic performances nor any of the expected confounders on academic performance. However both, depressiveness and test anxiety strongly correlated with the perceived imbalance between efforts spent and rewards received. Moreover, anxiety as a trait not only correlated with acute state anxiety before an exam but was also significantly correlated to the feeling of over-commitment. Depressiveness during the early years of medical school seems unrelated to test anxiety and academic performance. Instead, it strongly correlated with the psychosocial distress emanating from attending medical school and points at a perceived imbalance between efforts spent and rewards received.

  1. Test anxiety in medical school is unrelated to academic performance but correlates with an effort/reward imbalance

    PubMed Central

    Hahn, Henry; Kropp, Peter; Kirschstein, Timo; Rücker, Gernot; Müller-Hilke, Brigitte

    2017-01-01

    Purpose During their early years at medical school, students repeatedly criticize their workload, time constraints and test associated stress. At the same time, depressiveness and anxiety among first and second year medical students are on the rise. We therefore hypothesized that test anxiety may be related to depressiveness and considered cognitive and academic performances as confounders for the former and psychosocial distress for the latter. Methods A whole class of 200 second year students was invited to participate in the study. Anxiety as a trait, depressiveness, crystallized intelligence, verbal fluency and psychosocial distress were assessed using validated tests and questionnaires. Acute state anxiety and sympathetic stress parameters were measured in real life situations immediately before an oral and a written exam and paired tests were used to compare the individual anxieties at the various time points. Previous academic performances were self-reported, the results of the impending exams were monitored. Finally, correlations were performed to test for interrelatedness between academic performances and the various personal, cognitive and psychosocial factors. Results Acute test anxiety did not correlate with depressiveness nor did it correlate with previous nor impending academic performances nor any of the expected confounders on academic performance. However both, depressiveness and test anxiety strongly correlated with the perceived imbalance between efforts spent and rewards received. Moreover, anxiety as a trait not only correlated with acute state anxiety before an exam but was also significantly correlated to the feeling of over-commitment. Conclusion Depressiveness during the early years of medical school seems unrelated to test anxiety and academic performance. Instead, it strongly correlated with the psychosocial distress emanating from attending medical school and points at a perceived imbalance between efforts spent and rewards received. PMID:28182781

  2. Energy efficient engine high-pressure turbine component rig performance test report

    NASA Technical Reports Server (NTRS)

    Leach, K. P.

    1983-01-01

    A rig test of the cooled high-pressure turbine component for the Energy Efficient Engine was successfully completed. The principal objective of this test was to substantiate the turbine design point performance as well as determine off-design performance with the interaction of the secondary flow system. The measured efficiency of the cooled turbine component was 88.5 percent, which surpassed the rig design goal of 86.5 percent. The secondary flow system in the turbine performed according to the design intent. Characterization studies showed that secondary flow system performance is insensitive to flow and pressure variations. Overall, this test has demonstrated that a highly-loaded, transonic, single-stage turbine can achieve a high level of operating efficiency.

  3. Disentangling the cognitive components supporting Austin Maze performance in left versus right temporal lobe epilepsy.

    PubMed

    Hocking, Julia; Thomas, Hannah J; Dzafic, Ilvana; Williams, Rebecca J; Reutens, David C; Spooner, Donna M

    2013-12-01

    Neuropsychological tests requiring patients to find a path through a maze can be used to assess visuospatial memory performance in temporal lobe pathology, particularly in the hippocampus. Alternatively, they have been used as a task sensitive to executive function in patients with frontal lobe damage. We measured performance on the Austin Maze in patients with unilateral left and right temporal lobe epilepsy (TLE), with and without hippocampal sclerosis, compared to healthy controls. Performance was correlated with a number of other neuropsychological tests to identify the cognitive components that may be associated with poor Austin Maze performance. Patients with right TLE were significantly impaired on the Austin Maze task relative to patients with left TLE and controls, and error scores correlated with their performance on the Block Design task. The performance of patients with left TLE was also impaired relative to controls; however, errors correlated with performance on tests of executive function and delayed recall. The presence of hippocampal sclerosis did not have an impact on maze performance. A discriminant function analysis indicated that the Austin Maze alone correctly classified 73.5% of patients as having right TLE. In summary, impaired performance on the Austin Maze task is more suggestive of right than left TLE; however, impaired performance on this visuospatial task does not necessarily involve the hippocampus. The relationship of the Austin Maze task with other neuropsychological tests suggests that differential cognitive components may underlie performance decrements in right versus left TLE. © 2013.

  4. Performance and Symptom Validity Testing as a Function of Medical Board Evaluation in U.S. Military Service Members with a History of Mild Traumatic Brain Injury.

    PubMed

    Armistead-Jehle, Patrick; Cole, Wesley R; Stegman, Robert L

    2018-02-01

    The study was designed to replicate and extend pervious findings demonstrating the high rates of invalid neuropsychological testing in military service members (SMs) with a history of mild traumatic brain injury (mTBI) assessed in the context of a medical evaluation board (MEB). Two hundred thirty-one active duty SMs (61 of which were undergoing an MEB) underwent neuropsychological assessment. Performance validity (Word Memory Test) and symptom validity (MMPI-2-RF) test data were compared across those evaluated within disability (MEB) and clinical contexts. As with previous studies, there were significantly more individuals in an MEB context that failed performance (MEB = 57%, non-MEB = 31%) and symptom validity testing (MEB = 57%, non-MEB = 22%) and performance validity testing had a notable affect on cognitive test scores. Performance and symptom validity test failure rates did not vary as a function of the reason for disability evaluation when divided into behavioral versus physical health conditions. These data are consistent with past studies, and extends those studies by including symptom validity testing and investigating the effect of reason for MEB. This and previous studies demonstrate that more than 50% of SMs seen in the context of an MEB will fail performance validity tests and over-report on symptom validity measures. These results emphasize the importance of using both performance and symptom validity testing when evaluating SMs with a history of mTBI, especially if they are being seen for disability evaluations, in order to ensure the accuracy of cognitive and psychological test data. Published by Oxford University Press 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  5. Functional Task Test: 3. Skeletal Muscle Performance Adaptations to Space Flight

    NASA Technical Reports Server (NTRS)

    Ryder, Jeffrey W.; Wickwire, P. J.; Buxton, R. E.; Bloomberg, J. J.; Ploutz-Snyder, L.

    2011-01-01

    The functional task test is a multi-disciplinary study investigating how space-flight induced changes to physiological systems impacts functional task performance. Impairment of neuromuscular function would be expected to negatively affect functional performance of crewmembers following exposure to microgravity. This presentation reports the results for muscle performance testing in crewmembers. Functional task performance will be presented in the abstract "Functional Task Test 1: sensory motor adaptations associated with postflight alternations in astronaut functional task performance." METHODS: Muscle performance measures were obtained in crewmembers before and after short-duration space flight aboard the Space Shuttle and long-duration International Space Station (ISS) missions. The battery of muscle performance tests included leg press and bench press measures of isometric force, isotonic power and total work. Knee extension was used for the measurement of central activation and maximal isometric force. Upper and lower body force steadiness control were measured on the bench press and knee extension machine, respectively. Tests were implemented 60 and 30 days before launch, on landing day (Shuttle crew only), and 6, 10 and 30 days after landing. Seven Space Shuttle crew and four ISS crew have completed the muscle performance testing to date. RESULTS: Preliminary results for Space Shuttle crew reveal significant reductions in the leg press performance metrics of maximal isometric force, power and total work on R+0 (p<0.05). Bench press total work was also significantly impaired, although maximal isometric force and power were not significantly affected. No changes were noted for measurements of central activation or force steadiness. Results for ISS crew were not analyzed due to the current small sample size. DISCUSSION: Significant reductions in lower body muscle performance metrics were observed in returning Shuttle crew and these adaptations are likely contributors to impaired functional tasks that are ambulatory in nature (See abstract Functional Task Test: 1). Interestingly, no significant changes in central activation capacity were detected. Therefore, impairments in muscle function in response to short-duration space flight are likely myocellular rather than neuromotor in nature.

  6. Performance and Environmental Test Results of the High Voltage Hall Accelerator Engineering Development Unit

    NASA Technical Reports Server (NTRS)

    Kamhawi, Hani; Haag, Thomas; Huang, Wensheng; Shastry, Rohit; Pinero, Luis; Peterson, Todd; Mathers, Alex

    2012-01-01

    NASA Science Mission Directorate's In-Space Propulsion Technology Program is sponsoring the development of a 3.5 kW-class engineering development unit Hall thruster for implementation in NASA science and exploration missions. NASA Glenn and Aerojet are developing a high fidelity high voltage Hall accelerator that can achieve specific impulse magnitudes greater than 2,700 seconds and xenon throughput capability in excess of 300 kilograms. Performance, plume mappings, thermal characterization, and vibration tests of the high voltage Hall accelerator engineering development unit have been performed. Performance test results indicated that at 3.9 kW the thruster achieved a total thrust efficiency and specific impulse of 58%, and 2,700 sec, respectively. Thermal characterization tests indicated that the thruster component temperatures were within the prescribed material maximum operating temperature limits during full power thruster operation. Finally, thruster vibration tests indicated that the thruster survived the 3-axes qualification full-level random vibration test series. Pre and post-vibration test performance mappings indicated almost identical thruster performance. Finally, an update on the development progress of a power processing unit and a xenon feed system is provided.

  7. Analysis of the binder yield energy test as an indicator of fatigue behaviour of asphalt mixes

    NASA Astrophysics Data System (ADS)

    O'Connell, Johan; Mturi, Georges A. J.; Komba, Julius; Du Plessis, Louw

    2017-09-01

    Empirical binder testing has increasingly failed to predict pavement performance in South Africa, with fatigue cracking being one of the major forms of premature pavement distress. In response, it has become a national aspiration to incorporate a performance related fatigue test into the binder specifications for South Africa. The Binder Yield Energy Test (BYET) was the first in a series of tests analysed for its potential to predict the fatigue performance of the binder. The test is performed with the dynamic shear rheometer, giving two key parameters, namely, yield energy and shear strain at maximum shear stress (γτmax). The objective of the investigation was to perform a rudimentary evaluation of the BYET; followed by a more in-depth investigation should the initial BYET results prove promising. The paper discusses the results generated from the BYET under eight different conditions, using six different binders. The results are then correlated with four point bending beam fatigue test results obtained from asphalt mix samples that were manufactured from the same binders. Final results indicate that the BYET is not ideal as an indicator of fatigue performance.

  8. Psychometric Properties of Performance-based Measurements of Functional Capacity: Test-Retest Reliability, Practice Effects, and Potential Sensitivity to Change

    PubMed Central

    Leifker, Feea R.; Patterson, Thomas L.; Bowie, Christopher R.; Mausbach, Brent T.; Harvey, Philip D.

    2010-01-01

    Performance-based measures of the ability to perform social and everyday living skills are being more widely used to assess functional capacity in people with serious mental illnesses such as schizophrenia and bipolar disorder. Since they are also being used as outcome measures in pharmacological and cognitive remediation studies aimed at cognitive impairments in schizophrenia, understanding their measurement properties and potential sensitivity to change is important. In this study, the test-retest reliability, practice effects, and reliable change indices of two different performance-based functional capacity measures, the UCSD Performance-based skills assessment (UPSA) and Social skills performance assessment (SSPA) were examined over several different retest intervals in two different samples of people with schizophrenia (n’s=238 and 116) and a healthy comparison sample (n=109). These psychometric properties were compared to those of a neuropsychological assessment battery. Test-retest reliabilities of the long form of the UPSA ranged from r=.63 to r=.80 over follow-up periods up to 36 months in people with schizophrenia, while brief UPSA reliabilities ranged from r=.66 to r=.81. Test-retest reliability of the NP performance scores ranged from r=.77 to r=.79. Test-retest reliabilities of the UPSA were lower in healthy controls, while NP performance was slightly more reliable. SSPA test-retest reliability was lower. Practice effect sizes ranged from .05 to .16 for the UPSA and .07 to .19 for the NP assessment in patients, with HC having more practice effects. Reliable change intervals were consistent across NP and both FC measures, indicating equal potential for detection of change. These performance-based measures of functional capacity appear to have similar potential to be sensitive to change compared to NP performance in people with schizophrenia. PMID:20399613

  9. Performance map of a cluster detection test using extended power

    PubMed Central

    2013-01-01

    Background Conventional power studies possess limited ability to assess the performance of cluster detection tests. In particular, they cannot evaluate the accuracy of the cluster location, which is essential in such assessments. Furthermore, they usually estimate power for one or a few particular alternative hypotheses and thus cannot assess performance over an entire region. Takahashi and Tango developed the concept of extended power that indicates both the rate of null hypothesis rejection and the accuracy of the cluster location. We propose a systematic assessment method, using here extended power, to produce a map showing the performance of cluster detection tests over an entire region. Methods To explore the behavior of a cluster detection test on identical cluster types at any possible location, we successively applied four different spatial and epidemiological parameters. These parameters determined four cluster collections, each covering the entire study region. We simulated 1,000 datasets for each cluster and analyzed them with Kulldorff’s spatial scan statistic. From the area under the extended power curve, we constructed a map for each parameter set showing the performance of the test across the entire region. Results Consistent with previous studies, the performance of the spatial scan statistic increased with the baseline incidence of disease, the size of the at-risk population and the strength of the cluster (i.e., the relative risk). Performance was heterogeneous, however, even for very similar clusters (i.e., similar with respect to the aforementioned factors), suggesting the influence of other factors. Conclusions The area under the extended power curve is a single measure of performance and, although needing further exploration, it is suitable to conduct a systematic spatial evaluation of performance. The performance map we propose enables epidemiologists to assess cluster detection tests across an entire study region. PMID:24156765

  10. 78 FR 28733 - Medical Devices; General Hospital and Personal Use Monitoring Devices; Classification of the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-16

    ... Toxicology Testing. Labeling (dose limits). Electromagnetic incompatibility........ Electromagnetic... analysis and nonclinical testing must validate electromagnetic compatibility performance, wireless... electromagnetic compatibility performance, wireless performance, and electrical safety; and (4) Labeling must...

  11. Combined effects of altitude and high temperature on complex performance.

    DOT National Transportation Integrated Search

    1971-04-01

    Nine well-trained subjects were tested on a complex performance device designed to assess functions of relevance to aircrew activities. The tests, which involved tracking, monitoring, and mental arithmetic, were performed during exposure to altitude ...

  12. Test-Enhanced Learning in an Immunology and Infectious Disease Medicinal Chemistry/Pharmacology Course.

    PubMed

    Hernick, Marcy

    2015-09-25

    Objective. To develop a series of active-learning modules that would improve pharmacy students' performance on summative assessments. Design. A series of optional online active-learning modules containing questions with multiple formats for topics in a first-year (P1) course was created using a test-enhanced learning approach. A subset of module questions was modified and included on summative assessments. Assessment. Student performance on module questions improved with repeated attempts and was predictive of student performance on summative assessments. Performance on examination questions was higher for students with access to modules than for those without access to modules. Module use appeared to have the most impact on low performing students. Conclusion. Test-enhanced learning modules with immediate feedback provide pharmacy students with a learning tool that improves student performance on summative assessments and also may improve metacognitive and test-taking skills.

  13. Test-Enhanced Learning in an Immunology and Infectious Disease Medicinal Chemistry/Pharmacology Course

    PubMed Central

    2015-01-01

    Objective. To develop a series of active-learning modules that would improve pharmacy students’ performance on summative assessments. Design. A series of optional online active-learning modules containing questions with multiple formats for topics in a first-year (P1) course was created using a test-enhanced learning approach. A subset of module questions was modified and included on summative assessments. Assessment. Student performance on module questions improved with repeated attempts and was predictive of student performance on summative assessments. Performance on examination questions was higher for students with access to modules than for those without access to modules. Module use appeared to have the most impact on low performing students. Conclusion. Test-enhanced learning modules with immediate feedback provide pharmacy students with a learning tool that improves student performance on summative assessments and also may improve metacognitive and test-taking skills. PMID:27168610

  14. High Speed Prototype Car Test

    NASA Image and Video Library

    2014-01-10

    CAPE CANAVERAL, Fla. - An engineer readies a Hennessey Venom GT for test runs on the 3.5-mile long runway at the Shuttle Landing Facility at NASA's Kennedy Space Center in Florida. The flat concrete runway is one of the few places in the world where high performance automobiles can be tested for aerodynamic and safety designs. Hennessey Performance of Sealy, Texas, worked with Performance Power Racing in West Palm Beach to arrange use of the NASA facility. Performance Power Racing has conducted numerous engineering tests on the runway with a variety of vehicles. Photo credit: NASA/Kim Shiflett

  15. High Speed Prototype Car Test

    NASA Image and Video Library

    2014-01-10

    CAPE CANAVERAL, Fla. - Mechanics, engineers and Driver Brian Smith, in jumpsuit, ready a Hennessey Venom GT for test runs on the 3.5-mile long runway at the Shuttle Landing Facility at NASA's Kennedy Space Center in Florida. The flat concrete runway is one of the few places in the world where high performance automobiles can be tested for aerodynamic and safety designs. Hennessey Performance of Sealy, Texas, worked with Performance Power Racing in West Palm Beach to arrange use of the NASA facility. Performance Power Racing has conducted numerous engineering tests on the runway with a variety of vehicles. Photo credit: NASA/Kim Shiflett

  16. High Speed Prototype Car Test

    NASA Image and Video Library

    2014-01-10

    CAPE CANAVERAL, Fla. - Mechanics and engineers ready a Hennessey Venom GT for test runs on the 3.5-mile long runway at the Shuttle Landing Facility at NASA's Kennedy Space Center in Florida. The flat concrete runway is one of the few places in the world where high performance automobiles can be tested for aerodynamic and safety designs. Hennessey Performance of Sealy, Texas, worked with Performance Power Racing in West Palm Beach to arrange use of the NASA facility. Performance Power Racing has conducted numerous engineering tests on the runway with a variety of vehicles. Photo credit: NASA/Kim Shiflett

  17. Long life testing of spare Mariner Venus '67 hardware. [power conditioning electronics

    NASA Technical Reports Server (NTRS)

    Silverman, S. W.

    1976-01-01

    The faultless performance of the Mariner Venus '67 Power Conditioning Electronics (PCE) throughout six years of continuous operation in a simulated space environment is reported. Weekly functional tests supplemented by daily monitoring verified that the PCE equipment can perform to its intended functions for at least six years without apparent performance degradation. Performance throughout the test period was very stable, there are no circuit or redundancy improvements to be considered. When the equipment was examined after the test was completed, there was no evidence of any physical damage nor any difficulty in disconnecting the wiring connectors.

  18. Results of data base management system parameterized performance testing related to GSFC scientific applications

    NASA Technical Reports Server (NTRS)

    Carchedi, C. H.; Gough, T. L.; Huston, H. A.

    1983-01-01

    The results of a variety of tests designed to demonstrate and evaluate the performance of several commercially available data base management system (DBMS) products compatible with the Digital Equipment Corporation VAX 11/780 computer system are summarized. The tests were performed on the INGRES, ORACLE, and SEED DBMS products employing applications that were similar to scientific applications under development by NASA. The objectives of this testing included determining the strength and weaknesses of the candidate systems, performance trade-offs of various design alternatives and the impact of some installation and environmental (computer related) influences.

  19. Research notes : solar powered markers not up to challenge.

    DOT National Transportation Integrated Search

    2008-06-01

    ODOT performed preliminary tests on eight different models of solar powered raised pavement markers. These included environmental tests (extreme temperatures, immersion), optical performance tests, and observation tests. Federal Highway Administratio...

  20. Investigating the Effects of Exam Length on Performance and Cognitive Fatigue

    PubMed Central

    Jensen, Jamie L.; Berry, Dane A.; Kummer, Tyler A.

    2013-01-01

    This study examined the effects of exam length on student performance and cognitive fatigue in an undergraduate biology classroom. Exams tested higher order thinking skills. To test our hypothesis, we administered standard- and extended-length high-level exams to two populations of non-majors biology students. We gathered exam performance data between conditions as well as performance on the first and second half of exams within conditions. We showed that lengthier exams led to better performance on assessment items shared between conditions, possibly lending support to the spreading activation theory. It also led to greater performance on the final exam, lending support to the testing effect in creative problem solving. Lengthier exams did not result in lower performance due to fatiguing conditions, although students perceived subjective fatigue. Implications of these findings are discussed with respect to assessment practices. PMID:23950918

Top