NASA Technical Reports Server (NTRS)
Nettles, A. T.; Tucker, D. S.; Patterson, W. J.; Franklin, S. W.; Gordon, G. H.; Hart, L.; Hodge, A. J.; Lance, D. G.; Russel, S. S.
1991-01-01
A test run was performed on IM6/3501-6 carbon-epoxy in which the material was processed, machined into specimens, and tested for damage tolerance capabilities. Nondestructive test data played a major role in this element of composite characterization. A time chart was produced showing the time the composite material spent within each Branch or Division in order to identify those areas which produce a long turnaround time. Instrumented drop weight testing was performed on the specimens with nondestructive evaluation being performed before and after the impacts. Destructive testing in the form of cross-sectional photomicrography and compression-after-impact testing were used. Results show that the processing and machining steps needed to be performed more rapidly if data on composite material is to be collected within a reasonable timeframe. The results of the damage tolerance testing showed that IM6/3501-6 is a brittle material that is very susceptible to impact damage.
"Chair Stand Test" as Simple Tool for Sarcopenia Screening in Elderly Women.
Pinheiro, P A; Carneiro, J A O; Coqueiro, R S; Pereira, R; Fernandes, M H
2016-01-01
To investigate the association between sarcopenia and "chair stand test" performance, and evaluate this test as a screening tool for sarcopenia in community-dwelling elderly women. Cross-sectional Survey. 173 female individuals, aged ≥ 60 years and living in the urban area of the municipality of Lafaiete Coutinho, Bahia's inland, Brazil. The association between sarcopenia (defined by muscle mass, strength and/or performance loss) and performance in the "chair stand test" was tested by binary logistic regression technique. The ROC curve parameters were used to evaluate the diagnostic power of the test in sarcopenia screening. The significance level was set at 5 %. The model showed that the time spent for the "chair stand test" was positively associated (OR = 1.08; 95% CI = 1.01 - 1.16, p = 0.024) to sarcopenia, indicating that, for each 1 second increment in the test performance, the sarcopenia's probability increased by 8% in elderly women. The cut-off point that showed the best balance between sensitivity and specificity was 13 seconds. The performance of "chair stand test" showed predictive ability for sarcopenia, being an effective and simple screening tool for sarcopenia in elderly women. This test could be used for screening sarcopenic elderly women, allowing early interventions.
Bee Venom Pharmacopuncture Responses According to Sasang Constitution and Gender
Kim, Chaeweon; Lee, Kwangho
2013-01-01
Objectives: The current study was performed to compare the bee venom pharmacopuncture skin test reactions among groups with different sexes and Sasang constitutions. Methods: Between July 2012 and June 2013, all 76 patients who underwent bee venom pharmacopuncture skin tests and Sasang constitution diagnoses at Oriental Medicine Hospital of Sangji University were included in this study. The skin test was performed on the patient’s forearm intracutaneously with 0.05 ml of sweet bee venom (SBV) on their first visit. If the patients showed a positive response, the test was discontinued. On the other hand, if the patient showed a negative response, the test was performed on the opposite forearm intracutaneously with 0.05 ml of bee venom pharmacopuncture 25% on the next day or the next visit. Three groups were made to compare the differences in the bee venom pharmacopuncture skin tests according to sexual difference and Sasang constitution: group A showed a positive response to SBV, group B showed a positive response to bee venom pharmacopuncture 25%, and group C showed a negative response on all bee venom pharmacopuncture skin tests. Fisher’s exact test was performed to evaluate the differences statistically. Results: The results of the bee venom pharmacopuncture skin tests showed no significant differences according to Sasang constitution (P = 0.300) or sexual difference (P = 0.163). Conclusion: No significant differences on the results of bee venom pharmacopuncture skin tests were observed according to two factors, Sasang constitution and the sexual difference. PMID:25780682
Butyl rubber O-ring seals: Revision of test procedures for stockpile materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Domeier, L.A.; Wagter, K.R.
1996-12-01
Extensive testing showed little correlation between test slab and O-ring performance. New procedures, comparable to those used with the traditional test slabs, were defined for hardness, compression set, and tensile property testing on sacrificial O-ring specimens. Changes in target performance values were made as needed and were, in one case, tightened to reflect the O-ring performance data. An additional study was carried out on O-ring and slab performance vs cure cycle and showed little sensitivity of material performance to large changes in curing time. Aging and spectra of certain materials indicated that two sets of test slabs from current vendormore » were accidently made from EPDM rather than butyl rubber. Random testing found no O-rings made from EPDM. As a result, and additional spectroscope test will be added to the product acceptance procedures to verify the type of rubber compound used.« less
Evolution of Determinant Factors of Repeated Sprint Ability.
Pareja-Blanco, Fernando; Suarez-Arrones, Luis; Rodríguez-Rosell, David; López-Segovia, Manuel; Jiménez-Reyes, Pedro; Bachero-Mena, Beatriz; González-Badillo, Juan José
2016-12-01
The aim of this study was to investigate the changes in the relationships between repeated sprint ability (RSA) and anthropometric measures as well as fitness qualities in soccer players. Twenty-one professional soccer players performed several anthropometric and physical tests including countermovement vertical jumps (CMJs), a straight-line 30 m sprint (T30), an RSA test (6 x 20 + 20 m with 20 s recovery), a progressive isoinertial loading test in a full squat, a Yo-Yo Intermittent Recovery Test Level-1 (YYIRT-1) and a 20 m shuttle run test (20mSRT). The mean (RSAmean), the fastest (RSAbest), each single sprint time, and the percentage in a sprint decrease (%Dec) in the RSA test were calculated. RSAbest correlated significantly with RSAmean (r = .82) and with all single sprints (p < 0.05), showing a downward trend as the number of sprints performed increased. No significant relationship was observed between the %Dec and RSA performance. CMJs and the T30 also showed a correlation with RSA performance, whereas lower limb strength did not show any relationship with RSA performance. RSAmean showed significant (p < 0.05) relationships with body mass (r = .44), adiposity (r = .59) and the YYIRT-1 (r = -.62), increasing as the number of repeated sprints increased. The 20mSRT showed minimal relationships with RSA performance. In conclusion, maximal sprint capacity seems to be relevant for the RSA performance, mainly in the first sprints. However, high intermittent endurance capacity and low adiposity might help enhance the RSA performance when increasing the number of repeated sprints.
Evolution of Determinant Factors of Repeated Sprint Ability
Suarez-Arrones, Luis; Rodríguez-Rosell, David; López-Segovia, Manuel; Jiménez-Reyes, Pedro; Bachero-Mena, Beatriz; González-Badillo, Juan José
2016-01-01
Abstract The aim of this study was to investigate the changes in the relationships between repeated sprint ability (RSA) and anthropometric measures as well as fitness qualities in soccer players. Twenty-one professional soccer players performed several anthropometric and physical tests including countermovement vertical jumps (CMJs), a straight-line 30 m sprint (T30), an RSA test (6 x 20 + 20 m with 20 s recovery), a progressive isoinertial loading test in a full squat, a Yo-Yo Intermittent Recovery Test Level-1 (YYIRT-1) and a 20 m shuttle run test (20mSRT). The mean (RSAmean), the fastest (RSAbest), each single sprint time, and the percentage in a sprint decrease (%Dec) in the RSA test were calculated. RSAbest correlated significantly with RSAmean (r = .82) and with all single sprints (p < 0.05), showing a downward trend as the number of sprints performed increased. No significant relationship was observed between the %Dec and RSA performance. CMJs and the T30 also showed a correlation with RSA performance, whereas lower limb strength did not show any relationship with RSA performance. RSAmean showed significant (p < 0.05) relationships with body mass (r = .44), adiposity (r = .59) and the YYIRT-1 (r = -.62), increasing as the number of repeated sprints increased. The 20mSRT showed minimal relationships with RSA performance. In conclusion, maximal sprint capacity seems to be relevant for the RSA performance, mainly in the first sprints. However, high intermittent endurance capacity and low adiposity might help enhance the RSA performance when increasing the number of repeated sprints. PMID:28031763
ERIC Educational Resources Information Center
Yanagawa, Kozo; Green, Anthony
2008-01-01
The purpose of this study is to examine whether the choice between three multiple-choice listening comprehension test formats results in any difference in listening comprehension test performance. The three formats entail (a) allowing test takers to preview both the question stem and answer options prior to listening; (b) allowing test takers to…
Chouinard, M J; Rouleau, I
1997-11-01
We tested the validity of the 48-Pictures Test, a 2-alternative forced-choice recognition test, in detecting exaggerated memory impairments. This test maximizes subjective difficulty, through a large number of stimuli and shows minimal objective difficulty. We compared 17 suspected malingerers to 39 patients with memory impairments (6 amnesic, 15 frontal lobe dysfunctions, 18 other etiologies), and 17 normal adults instructed to simulate malingering on three memory tests: the 48-Pictures Test, the Rey Auditory Verbal Learning Test (RAVLT), and the Rey Complex Figure Test (RCFT). On the 48-Pictures Test, the clinical groups showed good recognition performance (amnesics: 85%; frontal dysfunction: 94%; other memory impairments: 97%), whereas the two simulator groups showed a poor performance (suspected malingerers: 62% correct; volunteer simulators 68% correct). The two other tests did not show a high degree of discrimination between the clinical groups and the simulator groups, except in 2 measures: the 2 simulator groups tended to show a performance decrement from the last recall trial to immediate recognition of the RAVLT and also performed better than the clinical groups on the immediate recall of the RCFT. A discriminant analysis with the latter 2 measures and the 48-Pictures Test correctly classified 96% of the participants. These results suggest that the 48-Pictures Test is a useful tool for the detection of possible simulated memory impairment and that when combined to the RAVLT recall-recognition difference score and to the immediate recall score on the RCFT can provide strong evidence of exaggerated memory impairment.
Thermal Performance Testing of EMU and CSAFE Liquid Cooling Garments
NASA Technical Reports Server (NTRS)
Rhodes, Richard; Bue, Grant; Hakam, Mark; Radford, Tamara
2013-01-01
Future exploration missions require the development of a new liquid cooling garment (LCG) that offers greater system reliability, is more comfortable, and maximizes thermal performance. To inform the development of a future LCG a thermal performance test was conducted to evaluate three factors: (1) the effect of the thermal comfort undergarment (TCU) on tactile and thermal comfort, (2) the comparable thermal performance of an CSAFE developed engineering evaluation unit (EEU) LCG, which uses a commercial-off-the-shelf (COTS) wicking garment as the base, and (3) the performance of a torso or upper body only LCG configuration to evaluate a proposed auxiliary loop configuration. To evaluate the thermal performance of each configuration a metabolic suit test was conducted, utilizing suited subjects to generate metabolic heat by walking on a treadmill at various speeds. Three (3) test subjects of similar height and weight produced a metabolic load for five tests by either resting (300-600 BTU/hr), walking at a slow pace (1200 BTU/hr), and walking at a brisk pace (2200 BTU/hr). During the test, data was collected that would allow us to track the heat transfer to the LCG and ventilation system to determine the thermal performance of the LCG configurations. Four different test configurations were tested, with one configuration tested twice. The test results show that the CSAFE EEU LCG and EMU LCG had comparable performance. The testing also showed that an auxiliary loop LCG, sized similarly to the shirt-only configuration, should provide adequate cooling for contingency scenarios. Finally, the testing showed the previous analysis that assumed a UA deterioration from the TCU was too conservative and the TCU may prove to be acceptable for future development with additional analysis and testing.
40 CFR 62.14680 - May I conduct performance testing less often?
Code of Federal Regulations, 2014 CFR
2014-07-01
... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...
40 CFR 62.14680 - May I conduct performance testing less often?
Code of Federal Regulations, 2013 CFR
2013-07-01
... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...
40 CFR 62.14680 - May I conduct performance testing less often?
Code of Federal Regulations, 2010 CFR
2010-07-01
... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...
40 CFR 62.14680 - May I conduct performance testing less often?
Code of Federal Regulations, 2012 CFR
2012-07-01
... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...
40 CFR 62.14680 - May I conduct performance testing less often?
Code of Federal Regulations, 2011 CFR
2011-07-01
... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...
NASA Technical Reports Server (NTRS)
Barna, P. S.
1996-01-01
Numerous tests were performed on the original Acoustic Quiet Flow Facility Three-Dimensional Model Tunnel, scaled down from the full-scale plans. Results of tests performed on the original scale model tunnel were reported in April 1995, which clearly showed that this model was lacking in performance. Subsequently this scale model was modified to attempt to possibly improve the tunnel performance. The modifications included: (a) redesigned diffuser; (b) addition of a collector; (c) addition of a Nozzle-Diffuser; (d) changes in location of vent-air. Tests performed on the modified tunnel showed a marked improvement in performance amounting to a nominal increase of pressure recovery in the diffuser from 34 percent to 54 percent. Results obtained in the tests have wider application. They may also be applied to other tunnels operating with an open test section not necessarily having similar geometry as the model under consideration.
PrismTech Data Distribution Service Java API Evaluation
NASA Technical Reports Server (NTRS)
Riggs, Cortney
2008-01-01
My internship duties with Launch Control Systems required me to start performance testing of an Object Management Group's (OMG) Data Distribution Service (DDS) specification implementation by PrismTech Limited through the Java programming language application programming interface (API). DDS is a networking middleware for Real-Time Data Distribution. The performance testing involves latency, redundant publishers, extended duration, redundant failover, and read performance. Time constraints allowed only for a data throughput test. I have designed the testing applications to perform all performance tests when time is allowed. Performance evaluation data such as megabits per second and central processing unit (CPU) time consumption were not easily attainable through the Java programming language; they required new methods and classes created in the test applications. Evaluation of this product showed the rate that data can be sent across the network. Performance rates are better on Linux platforms than AIX and Sun platforms. Compared to previous C++ programming language API, the performance evaluation also shows the language differences for the implementation. The Java API of the DDS has a lower throughput performance than the C++ API.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 34 2013-07-01 2013-07-01 false What emission testing must I perform... emission testing must I perform for my application for a certificate of conformity? This section describes the emission testing you must perform to show compliance with the emission standards in subpart B of...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 33 2014-07-01 2014-07-01 false What emission testing must I perform... emission testing must I perform for my application for a certificate of conformity? This section describes the emission testing you must perform to show compliance with the emission standards in subpart B of...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 32 2010-07-01 2010-07-01 false What emission testing must I perform... emission testing must I perform for my application for a certificate of conformity? This section describes the emission testing you must perform to show compliance with the emission standards in subpart B of...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 34 2012-07-01 2012-07-01 false What emission testing must I perform... emission testing must I perform for my application for a certificate of conformity? This section describes the emission testing you must perform to show compliance with the emission standards in subpart B of...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 33 2011-07-01 2011-07-01 false What emission testing must I perform... emission testing must I perform for my application for a certificate of conformity? This section describes the emission testing you must perform to show compliance with the emission standards in subpart B of...
Thermoelectric generator testing and RTG degradation mechanisms evaluation. Progress report No. 33
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lockwood, A.; Stapfer, G.
1979-12-01
The n-type selenide legs after 10,600 hours continue to show agreement with the 3M Co. published data. In the ingradient testing after 11,378 hours the n-legs show comparable performance to the reported 3M data. The new design p-type legs were placed on test. The remaining MHW generator on test Q1-A has accumulated 19,567 hours and performance remains stable. Three 18 couple modules S/N-1, 2, and 3 previously tested at RCA were received for JPL test and evaluation. S/N-1 has 1700 hours testing at JPL with results indistinguishable from those at the end of RCA testing in 1977. The performances ofmore » LES 8/9 generators are following DEGRA predications after 31,824 hours. The performance of the Voyager 1 and 2 RTGs is reported after 19,577 hours and 20,122 hours of operation, respectively.« less
Predictive Performance Assessment: Trait and State Dimensions Should not be Confused
NASA Astrophysics Data System (ADS)
Pattyn, N.; Migeotte, P.-F.; Morais, J.; Cluydts, R.; Soetens, E.; Meeusen, R.; de Schutter, G.; Nederhof, E.; Kolinsky, R.
2008-06-01
One of the major aims of performance investigation is to obtain a measure predicting real-life performance, in order to prevent consequences of a potential decrement. Whereas the predictive validity of such assessment has been extensively described for long-term outcomes, as is the case for testing in selection context, equivalent evidence is lacking regarding the short-term predictive value of cognitive testing, i.e., whether these results reflect real-life performance on an immediately subsequent task. In this series of experiments, we investigated both medium-term and short-term predictive value of psychophysiological testing with regard to real-life performance in two operational settings: military student pilots with regard to their success on an evaluation flight, and special forces candidates with regard to their performance on their training course. Our results showed some relationships between test performance and medium-term outcomes. However, no short-term predictive value could be identified for cognitive testing, despite the fact physiological data showed interesting trends. We recommend a critical distinction between "state" and "trait" dimensions of performance with regard to the predictive value of testing.
Parabolic trough receiver heat loss and optical efficiency round robin 2015/2016
NASA Astrophysics Data System (ADS)
Pernpeintner, Johannes; Schiricke, Björn; Sallaberry, Fabienne; de Jalón, Alberto García; López-Martín, Rafael; Valenzuela, Loreto; de Luca, Antonio; Georg, Andreas
2017-06-01
A round robin for parabolic trough receiver heat loss and optical efficiency in the laboratory was performed between five institutions using five receivers in 2015/2016. Heat loss testing was performed at three cartridge heater test benches and one Joule heating test bench in the temperature range between 100 °C and 550 °C. Optical efficiency testing was performed with two spectrometric test bench and one calorimetric test bench. Heat loss testing results showed standard deviations at the order of 6% to 12 % for most temperatures and receivers and a standard deviation of 17 % for one receiver at 100 °C. Optical efficiency is presented normalized for laboratories showing standard deviations of 0.3 % to 1.3 % depending on the receiver.
Full-scale transmission testing to evaluate advanced lubricants
NASA Technical Reports Server (NTRS)
Lewicki, David G.; Decker, Harry J.; Shimski, John T.
1992-01-01
Experimental tests were performed on the OH-58A helicopter main rotor transmission in the NASA Lewis 500 hp helicopter transmission test stand. The testing was part of a lubrication program. The objectives are to develop and show a separate lubricant for gearboxes with improved performance in life and load carrying capacity. The goal was to develop a testing procedure to fail certain transmission components using a MIL-L-23699 based reference oil and then to run identical tests with improved lubricants and show improved performance. The tests were directed at parts that failed due to marginal lubrication from Navy field experience. These failures included mast shaft bearing micropitting, sun gear and planet bearing fatigue, and spiral bevel gear scoring. A variety of tests were performed and over 900 hrs of total run time accumulated for these tests. Some success was achieved in developing a testing procedure to produce sun gear and planet bearing fatigue failures. Only marginal success was achieved in producing mast shaft bearing micropitting and spiral bevel gear scoring.
Peripheral visual performance enhancement by neurofeedback training.
Nan, Wenya; Wan, Feng; Lou, Chin Ian; Vai, Mang I; Rosa, Agostinho
2013-12-01
Peripheral visual performance is an important ability for everyone, and a positive inter-individual correlation is found between the peripheral visual performance and the alpha amplitude during the performance test. This study investigated the effect of alpha neurofeedback training on the peripheral visual performance. A neurofeedback group of 13 subjects finished 20 sessions of alpha enhancement feedback within 20 days. The peripheral visual performance was assessed by a new dynamic peripheral visual test on the first and last training day. The results revealed that the neurofeedback group showed significant enhancement of the peripheral visual performance as well as the relative alpha amplitude during the peripheral visual test. It was not the case in the non-neurofeedback control group, which performed the tests within the same time frame as the neurofeedback group but without any training sessions. These findings suggest that alpha neurofeedback training was effective in improving peripheral visual performance. To the best of our knowledge, this is the first study to show evidence for performance improvement in peripheral vision via alpha neurofeedback training.
Thermal Performance Testing of EMU and CSAFE Liquid Cooling Gannents
NASA Technical Reports Server (NTRS)
Rhodes, Richard; Bue, Grant; Meginnis, Ian; Hakam, Mary; Radford, Tamara
2013-01-01
Future exploration missions require the development of a new liquid cooling garment (LCG) to support the next generation extravehicular activity (EVA) suit system. The new LCG must offer greater system reliability, optimal thermal performance as required by mission directive, and meet other design requirements including improved tactile comfort. To advance the development of a future LCG, a thermal performance test was conducted to evaluate: (1) the comparable thermal performance of the EMU LCG and the CSAFE developed engineering evaluation unit (EEU) LCG, (2) the effect of the thermal comfort undergarment (TCU) on the EMU LCG tactile and thermal comfort, and (3) the performance of a torso or upper body only LCG shirt to evaluate a proposed auxiliary loop. To evaluate the thermal performance of each configuration, a metabolic test was conducted using the Demonstrator Spacesuit to create a relevant test environment. Three (3) male test subjects of similar height and weight walked on a treadmill at various speeds to produce three different metabolic loads - resting (300-600 BTU/hr), walking at a slow pace (1200 BTU/hr), and walking at a brisk pace (2200 BTU/hr). Each subject participated in five tests - two wearing the CSAFE full LCG, one wearing the EMU LCG without TCUs, one wearing the EMU LCG with TCUs, and one with the CSAFE shirt-only. During the test, performance data for the breathing air and cooling water systems and subject specific data was collected to define the thermal performance of the configurations. The test results show that the CSAFE EEU LCG and EMU LCG with TCU had comparable performance. The testing also showed that an auxiliary loop LCG, sized similarly to the shirt-only configuration, should provide adequate cooling for contingency scenarios. Finally, the testing showed that the TCU did not significantly hinder LCG heat transfer, and may prove to be acceptable for future suit use with additional analysis and testing.
Full scale evaluation of diffuser ageing with clean water oxygen transfer tests.
Krampe, J
2011-01-01
Aeration is a crucial part of the biological wastewater treatment in activated sludge systems and the main energy user of WWTPs. Approximately 50 to 60% of the total energy consumption of a WWTP can be attributed to the aeration system. The performance of the aeration system, and in the case of fine bubble diffused aeration the diffuser performance, has a significant impact on the overall plant efficiency. This paper seeks to isolate the changes of the diffuser performance over time by eliminating all other influencing parameters like sludge retention time, surfactants and reactor layout. To achieve this, different diffusers have been installed and tested in parallel treatment trains in two WWTPs. The diffusers have been performance tested in clean water tests under new conditions and after one year of operation. A set of material property tests describing the diffuser membrane quality was also performed. The results showed a significant drop in the performance of the EPDM diffuser in the first year which resulted in similar oxygen transfer efficiency around 16 g/m3/m for all tested systems. Even though the tested silicone diffusers did not show a drop in performance they had a low efficiency in the initial tests. The material properties indicate that the EPDM performance loss is partly due to the washout of additives.
ERIC Educational Resources Information Center
Obenland, Carrie A.; Munson, Ashlyn H.; Hutchinson, John S.
2013-01-01
Active learning is becoming more prevalent in large science classrooms, and this study shows the impact on performance of being vocal during Socratic questioning in a General Chemistry course. 800 college students over a two year period were given a pre and post-test using the Chemistry Concept Reasoning Test. The pre-test results showed that…
40 CFR 60.2155 - May I conduct performance testing less often?
Code of Federal Regulations, 2010 CFR
2010-07-01
... pollutant (particulate matter, hydrogen chloride, or opacity) over 3 consecutive years show that you comply... limitation for particulate matter, hydrogen chloride, or opacity, you may choose to conduct performance tests... matter, hydrogen chloride, or opacity, you must conduct annual performance tests for that pollutant until...
2008-10-01
Equipment Department of the Dutch Ministry of Defence tasked TNO Defence, Security and Safety to perform AP mine shoe tests to study the protection level...would not provide more insight. Therefore only two tests at 75 g were performed . The test results are summarized in Table 2. The high speed video...be able to better place foot into shoe . But still damage of gelatine prior to test. Pretest x-ray performed to show damage prior to test. The
Test techniques for determining laser ranging system performance
NASA Technical Reports Server (NTRS)
Zagwodzki, T. W.
1981-01-01
Procedures and results of an on going test program intended to evaluate laser ranging system performance levels in the field as well as in the laboratory are summarized. Tests show that laser ranging system design requires consideration of time biases and RMS jitters of individual system components. All simple Q switched lasers tested were found to be inadequate for 10 centimeter ranging systems. Timing discriminators operating over a typical 100:1 dynamic signal range may introduce as much as 7 to 9 centimeters of range bias. Time interval units commercially available today are capable of half centimeter performance and are adequate for all field systems currently deployed. Photomultipliers tested show typical tube time biases of one centimeter with single photoelectron transit time jitter of approximately 10 centimeters. Test results demonstrate that NASA's Mobile Laser Ranging System (MOBLAS) receiver configuration is limiting system performance below the 100 photoelectron level.
Knox's Cube Imitation Test: A Historical Review and an Experimental Analysis
ERIC Educational Resources Information Center
Richardson, John T. E.
2005-01-01
The cube imitation test was developed by Knox (1913) as a nonverbal test of intelligence. Many variants show satisfactory reliability, but performance is correlated both with Verbal IQ and with Performance IQ. Performance is impaired by cerebral lesions but unrelated to the side of lesion. Examinees describe both verbal and visuospatial…
Kim, Jin Chul; Chon, Jinmann; Kim, Hee Sang; Lee, Jong Ha; Yoo, Seung Don; Kim, Dong Hwan; Lee, Seung Ah; Han, Yoo Jin; Lee, Hyun Seok; Lee, Bae Youl; Soh, Yun Soo; Won, Chang Won
2017-04-01
To evaluate the association between baseline characteristics, three physical performance tests and fall history in a sample of the elderly from Korean population. A total of 307 participants (mean age, 76.70±4.85 years) were categorized into one of two groups, i.e., fallers and non-fallers. Fifty-two participants who had reported falling unexpectedly at least once in the previous 12 months were assigned to the fallers group. Physical performance tests included Short Physical Performance Battery (SPPB), Berg Balance Scale (BBS), Timed Up and Go test. The differences between the two study groups were compared and we analyzed the correlations between fall histories and physical performance tests. SPPB demonstrated a significant association with fall history. Although the BBS total scores did not show statistical significance, two dynamic balance test items of BBS (B12 and B13) showed a significant association among fallers. This study suggests that SPPB and two dynamic balance test items of the BBS can be used in screening for risk of falls in an ambulatory elderly population.
NASA Astrophysics Data System (ADS)
Huynh, Trong-Phuoc; Hwang, Chao-Lung; Yang, Shu-Ti
2017-12-01
This experimental study evaluated the performance of normal ordinary Portland cement (OPC) concrete and high-performance concrete (HPC) that were designed by the conventional method (ACI) and densified mixture design algorithm (DMDA) method, respectively. Engineering properties and durability performance of both the OPC and HPC samples were studied using the tests of workability, compressive strength, water absorption, ultrasonic pulse velocity, and electrical surface resistivity. Test results show that the HPC performed good fresh property and further showed better performance in terms of strength and durability as compared to the OPC.
NASA Technical Reports Server (NTRS)
Stefko, George L.; Rose, Gayle E.; Podboy, Gary G.
1987-01-01
High speed wind tunnel aerodynamic performance tests of the SR-7A advanced prop-fan have been completed in support of the Prop-Fan Test Assessment (PTA) flight test program. The test showed that the SR-7A model performed aerodynamically very well. At the cruise design condition, the SR-7A prop fan had a high measured net efficiency of 79.3 percent.
Implementation and performance test of cloud platform based on Hadoop
NASA Astrophysics Data System (ADS)
Xu, Jingxian; Guo, Jianhong; Ren, Chunlan
2018-01-01
Hadoop, as an open source project for the Apache foundation, is a distributed computing framework that deals with large amounts of data and has been widely used in the Internet industry. Therefore, it is meaningful to study the implementation of Hadoop platform and the performance of test platform. The purpose of this subject is to study the method of building Hadoop platform and to study the performance of test platform. This paper presents a method to implement Hadoop platform and a test platform performance method. Experimental results show that the proposed test performance method is effective and it can detect the performance of Hadoop platform.
NASA Astrophysics Data System (ADS)
Marpaung, M. G.; Sareharto, T. P.; Purwanti, A.; Hermawati, D.
2017-02-01
Academic performance becomes an important determinant of individual quality. it is determined by the function of affective, cognitive, psychomotor, and intelligence. Brain gym can improve learning processes and integrate all areas that related to the learning process. To prove the effect of brain gym towards academic performance of children aged 10-12 years. This study was a quasy experiment study with one group pre and post test design. Samples (n=18 male=7 and female=11) were taken from five and six grader and conducted in Tembalang and Pedalangan Elementary School, Semarang. Pretest were administered, followed by brain gym, and post test administered in the end of study. The measurement of Intelligence Quotient pre and post test using Culture Fair Intelligence Test Scale 2. Among the 18 subjects (male=7 and female=11) the average of academic performance and IQ score after brain gym showed improvement. The Improvement of IQ score with Culture Fair Test Scale 2 was analyzed by Dependent T test showed significant results (p=0,000). The improvement of Bahasa score was analyzed by Wilcoxon test showed significant results (p=0,001), an unsignificant result were shown in Mathematics p=0,079 and natural sciences p=0,306. Brain gym can increase academic performance of children aged 10-12 years old.
ERIC Educational Resources Information Center
Erin, Jane N.; Hong, Sunggye; Schoch, Christina; Kuo, YaJu
2006-01-01
This study compared the test scores and time required by high school students who are blind, sighted, or have low vision to complete tests administered in written and oral formats. The quantitative results showed that the blind students performed better on multiple-choice tests in braille and needed more time while taking tests in braille. The…
Jeoung, Bogja
2017-01-01
The purpose of this study was to evaluate the relationship between sitting volleyball performance and the field fitness of sitting volleyball players. Forty-five elite sitting volleyball players participated in 10 field fitness tests. Additionally, the players’ head coach and coach assessed their volleyball performance (receive and defense, block, attack, and serve). Data were analyzed with SPSS software version 21 by using correlation and regression analyses, and the significance level was set at P< 0.05. The results showed that chest pass, overhand throw, one-hand throw, one-hand side throw, splint, speed endurance, reaction time, and graded exercise test results had a statistically significant influence on the players’ abilities to attack, serve, and block. Grip strength, t-test, speed, and agility showed a statistically significant relationship with the players’ skill at defense and receive. Our results showed that chest pass, overhand throw, one-hand throw, one-hand side throw, speed endurance, reaction time, and graded exercise test results had a statistically significant influence on volleyball performance. PMID:29326896
Research: Testing of a Novel Portable Body Temperature Conditioner Using a Thermal Manikin.
Heller, Daniel; Heller, Alex; Moujaes, Samir; Williams, Shelley J; Hoffmann, Ryan; Sarkisian, Paul; Khalili, Kaveh; Rockenfeller, Uwe; Browder, Timothy D; Kuhls, Deborah A; Fildes, John J
2016-01-01
A battery-operated active cooling/heating device was developed to maintain thermoregulation of trauma victims in austere environments while awaiting evacuation to a hospital for further treatment. The use of a thermal manikin was adopted for this study in order to simulate load testing and evaluate the performance of this novel portable active cooling/heating device for both continuous (external power source) and battery power. The performance of the portable body temperature conditioner (PBTC) was evaluated through cooling/heating fraction tests to analyze the heat transfer between a thermal manikin and circulating water blanket to show consistent performance while operating under battery power. For the cooling/heating fraction tests, the ambient temperature was set to 15°C ± 1°C (heating) and 30°C ± 1°C (cooling). The PBTC water temperature was set to 37°C for the heating mode tests and 15°C for the cooling mode tests. The results showed consistent performance of the PBTC in terms of cooling/heating capacity while operating under both continuous and battery power. The PBTC functioned as intended and shows promise as a portable warming/cooling device for operation in the field.
Simonsen, Daniel; Nielsen, Ida F; Spaich, Erika G; Andersen, Ole K
2017-05-02
The present paper describes the design and evaluation of an automated version of the Modified Jebsen Test of Hand Function (MJT) based on the Microsoft Kinect sensor. The MJT was administered twice to 11 chronic stroke subjects with varying degrees of hand function deficits. The test times of the MJT were evaluated manually by a therapist using a stopwatch, and automatically using the Microsoft Kinect sensor. The ground truth times were assessed based on inspection of the video-recordings. The agreement between the methods was evaluated along with the test-retest performance. The results from Bland-Altman analysis showed better agreement between the ground truth times and the automatic MJT time evaluations compared to the agreement between the ground truth times and the times estimated by the therapist. The results from the test-retest performance showed that the subjects significantly improved their performance in several subtests of the MJT, indicating a practice effect. The results from the test showed that the Kinect can be used for automating the MJT.
Reliability Testing of NASA Piezocomposite Actuators
NASA Technical Reports Server (NTRS)
Wilkie, W.; High, J.; Bockman, J.
2002-01-01
NASA Langley Research Center has developed a low-cost piezocomposite actuator which has application for controlling vibrations in large inflatable smart space structures, space telescopes, and high performance aircraft. Tests show the NASA piezocomposite device is capable of producing large, directional, in-plane strains on the order of 2000 parts-per-million peak-to-peak, with no reduction in free-strain performance to 100 million electrical cycles. This paper describes methods, measurements, and preliminary results from our reliability evaluation of the device under externally applied mechanical loads and at various operational temperatures. Tests performed to date show no net reductions in actuation amplitude while the device was moderately loaded through 10 million electrical cycles. Tests were performed at both room temperature and at the maximum operational temperature of the epoxy resin system used in manufacture of the device. Initial indications are that actuator reliability is excellent, with no actuator failures or large net reduction in actuator performance.
NASA Technical Reports Server (NTRS)
Wright, Sarah E.; Ungar, Eugene K.
2017-01-01
Post-test examination and data analysis that followed a two week long vacuum test showed that numerous self-stick thermocouples became detached from the test article. The thermocouples were reattached with thermally conductive epoxy and the test was repeated to obtain the required data. Because the thermocouple detachment resulted in significant expense and rework, it was decided to investigate the temporary attachment methods used around NASA and to perform a test to assess their efficacy. The present work describes the testing that was performed in early and mid-2017. The test article and the temporary thermocouple attachment methods tested are described. During the first test, fully half of the thermocouples detached - although the detachment showed subtly in the data for some. The second test was performed to confirm the data from the first test and to investigate the effect of test article and thermocouple grounding. The results of the testing over temperatures ranging from -150 to 200degF are detailed and preliminary recommendations are made for temporary thermocouple attachment methods.
2003-11-20
KENNEDY SPACE CENTER, FLA. - This view shows the tiles below the windshield on the orbiter Atlantis. A gap test is being performed on the tiles as part of return-to-flight activities. Atlantis is scheduled for mission STS-114, a return-to-flight test mission to the International Space Station.
Sex and cultural differences in spatial performance between Japanese and North Americans.
Sakamoto, Maiko; Spiers, Mary V
2014-04-01
Previous studies have suggested that Asians perform better than North Americans on spatial tasks but show smaller sex differences. In this study, we evaluated the relationship between long-term experience with a pictorial written language and spatial performance. It was hypothesized that native Japanese Kanji (a complex pictorial written language) educated adults would show smaller sex differences on spatial tasks than Japanese Americans or North Americans without Kanji education. A total of 80 young healthy participants (20 native Japanese speakers, 20 Japanese Americans-non Japanese speaking, and 40 North Americans-non Japanese speaking) completed the Rey Complex Figure Test (RCFT), the Mental Rotations Test (MRT), and customized 2D and 3D spatial object location memory tests. As predicted, main effects revealed men performed better on the MRT and RCFT and women performed better on the spatial object location memory tests. Also, as predicted, native Japanese performed better on all tests than the other groups. In contrast to the other groups, native Japanese showed a decreased magnitude of sex differences on aspects of the RCFT (immediate and delayed recall) and no significant sex difference on the efficiency of the strategy used to copy and encode the RCFT figure. This study lends support to the idea that intensive experience over time with a pictorial written language (i.e., Japanese Kanji) may contribute to increased spatial performance on some spatial tasks as well as diminish sex differences in performance on tasks that most resemble Kanji.
ERIC Educational Resources Information Center
van Gog, Tamara; Kester, Liesbeth; Dirkx, Kim; Hoogerheide, Vincent; Boerboom, Joris; Verkoeijen, Peter P. J. L.
2015-01-01
Four experiments investigated whether the testing effect also applies to the acquisition of problem-solving skills from worked examples. Experiment 1 (n?=?120) showed no beneficial effects of testing consisting of "isomorphic" problem solving or "example recall" on final test performance, which consisted of isomorphic problem…
Rabin, Bernard M; Joseph, James A; Shukitt-Hale, Barbara; Carrihill-Knoll, Kirsty L
2012-02-01
Previous research has shown a progressive deterioration in cognitive performance in rats exposed to (56)Fe particles as a function of age. The present experiment was designed to evaluate the effects of age of irradiation independently of the age of testing. Male Fischer-344 rats, 2, 7, 12, and 16 months of age, were exposed to 25-200 cGy of (56)Fe particles (1,000 MeV/n). Following irradiation, the rats were trained to make an operant response on an ascending fixed-ratio reinforcement schedule. When performance was evaluated as a function of both age of irradiation and testing, the results showed a significant effect of age on the dose needed to produce a performance decrement, such that older rats exposed to lower doses of (56)Fe particles showed a performance decrement compared to younger rats. When performance was evaluated as a function of age of irradiation with the age of testing held constant, the results indicated that age of irradiation was a significant factor influencing operant responding, such that older rats tested at similar ages and exposed to similar doses of (56)Fe particles showed similar performance decrements. The results are interpreted as indicating that the performance decrement is not a function of age per se, but instead is dependent upon an interaction between the age of irradiation, the age of testing, and exposure to HZE particles. The nature of these effects and how age of irradiation affects cognitive performance after an interval of 15 to 16 months remains to be established.
Age Effects on Wechsler Adult Intelligence Scale-Revised Tests.
ERIC Educational Resources Information Center
Sattler, Jerome M.
1982-01-01
Studied age norms for 11 individual Wechsler Adult Intelligence Scale-Revised (WAIS-R) tests. Digit Symbol showed the most decline. Results suggest that fluid intelligence, as measured by the performance scale tests, shows more of a decline with age than crystallized intelligence, as measured by the verbal scale tests. (Author)
Using the bending beam rheometer for low temperature testing of asphalt mixtures : final report.
DOT National Transportation Integrated Search
2016-07-01
This work showed that the bending beam rheometer is a viable test to determine the low temperature performance of : asphalt mixtures; it balances the rigor required of any mechanical test and the relation to field performance with the : practicality ...
Differential effects of scopolamine and amphetamine on microcomputer-based performance tests
NASA Technical Reports Server (NTRS)
Kennedy, Robert S.; Odenheimer, Robert C.; Baltzley, Dennis R.; Dunlap, William P.; Wood, Charles D.
1990-01-01
The effects of four weekly treatments with scopolamine (1.0 mg) and d-amphetamine (10 mg), separately or in combination, on human performance were investigated in 16 subjects undergoing nine performance tests from a menu of microcomputer-based tests administered after the treatment. It was d-amphetamine treatment that enhanced the results of motor and perceptual speed tests, while scopolamine had no effect on these tests. Two of the five cognitive tests showed reductions with scopolamine. The effects of scopolamine in this and other studies are considered in terms of a model which implies that the magnitude of the performance deficit depends on the performance type and the dosage level of the drug.
ERIC Educational Resources Information Center
Escudier, M. P.; Newton, T. J.; Cox, M. J.; Reynolds, P. A.; Odell, E. W.
2011-01-01
This study compared higher education dental undergraduate student performance in online assessments with performance in traditional paper-based tests and investigated students' perceptions of the fairness and acceptability of online tests, and showed performance to be comparable. The project design involved two parallel cross-over trials, one in…
Otero-Esquina, Carlos; de Hoyo Lora, Moisés; Gonzalo-Skok, Óliver; Domínguez-Cobo, Sergio; Sánchez, Hugo
2017-11-01
The aim of this study was to analyse the effects of a combined strength-training programme (full-back squat, YoYo TM leg curl, plyometrics and sled towing exercises) on performance in elite young soccer players and to examine the effects when this training programme was performed one or two days per week. Thirty-six male soccer players (U-17 to U-19) were recruited and assigned to experimental groups (EXP1: 1 s w -1 ; EXP2: 2 s w -1 ) or a control group (CON). Performance was assessed through a countermovement jump (CMJ) test (relative peak power [CMJ PP ] and CMJ height [CMJ H ]), a 20-m linear sprint test with split-times at 10-m, and a change of direction test (V-cut test) 1 week before starting the training programme and also 1 week after performing such training programme. Within-group analysis showed substantial improvements in CMJ variables (ES: 0.39-0.81) and COD (ES: 0.70 and 0.76) in EXP1 and EXP2, while EXP2 also showed substantial enhancements in all linear sprinting tests (ES: 0.43-0.52). Between-group analysis showed substantially greater improvements in CMJ variables (ES: 0.39-0.68) in experimental groups in comparison to CON. Furthermore, EXP2 achieved a substantial better performance in 20-m (ES: 0.48-0.64) than EXP1 and CON. Finally, EXP2 also showed greater enhancements in 10-m (ES: 0.50) and V-cut test (ES: 0.52) than EXP1. In conclusion, the combined strength-training programme improved jumping ability, independently of training frequency, though the achievement of two sessions per week also enhanced sprinting abilities (linear and COD) in young soccer players.
[Action-oriented versus state-oriented reactions to experimenter-induced failures].
Brunstein, J C
1989-01-01
The present study assessed different effects of action-oriented versus state-oriented styles of coping with failure on achievement-related performance and cognition. In a learned helplessness experiment, students were exposed to an academic failure situation and were then tested on a series of problem-solving tasks, either immediately after the pretreatment or after a delay of 24 hours. Performance and cognitive concomitants were measured during both experimental periods. Results demonstrated that action orientation was associated with self-immunizing cognitions during helplessness training. Action-oriented participants improved their performance level even after repeated failure feedbacks. Moreover, action-oriented students assigned to the delayed test condition responded with increased striving for success and showed performance increments, even in comparison with control subjects. In contrast, state-oriented participants developed symptoms of helplessness and showed impaired performance during failure inductions. In later tests on problem-solving tasks, state-oriented groups responded with increased fear of failure. Independent of immediate or delayed test conditions, they soon lapsed into new performance decrements.
Comparison of indoor-outdoor thermal performance for the Sunpak evacuated tube liquid collector
NASA Technical Reports Server (NTRS)
1980-01-01
Performance data for current Sunpak production collectors is presented. The effects of an improved manifold are seen from the test results. The test results show excellent correlation between the solar simulator derived test results and outdoor test results. Also, because of different incident angle modifiers, the all-day efficiency of this collector with a diffuse reflector is comparable to the performance with the standard shaped specular reflector.
Effects of Minority Status on Facial Recognition and Naming Performance.
ERIC Educational Resources Information Center
Roberts, Richard J.; Hamsher, Kerry
1984-01-01
Examined the differential effects of minority status in Blacks (N=94) on a facial recognition test and a naming test. Results showed that performance on the facial recognition test was relatively free of racial bias, but this was not the case for visual naming. (LLL)
Men and Women: Equal in Accounting?
ERIC Educational Resources Information Center
Park, L. Jane; And Others
1994-01-01
Data from 131 male and 177 female accounting students were derived from test scores, student estimation of performance, California Psychological Inventory, and State-Trait Anxiety Inventory. No significant differences between the sexes appeared in test performance or grade point average. Psychological tests showed male self-perceptions to be…
Harness, B Z; Bental, E; Carmon, A
1976-03-01
Cognition and performance of patients with localized and diffuse brain damage was evaluated through the application of objective perceptual testing. A series of visual perceptual and verbal tests, memory tests, as well as reaction time tasks were administered to the patients by logic programming equipment. In order to avoid a bias due to communicative disorders, all responses were motor, and achievement was scored in terms of correct identification and latencies of response. Previously established norms based on a large sample of non-brain-damaged hospitalized patients served to standardize the performance of the brain-damaged patient since preliminary results showed that age and educational level constitute an important variable affecting performance of the control group. The achievement of brain-damaged patients, corrected for these factors, was impaired significantly in all tests with respect to both recognition and speed of performance. Lateralized effects of brain damage were not significantly demonstrated. However, when the performance was analyzed with respect to the locus of visual input, it was found that patients with right hemispheric lesions showed impairment mainly on perception of figurative material, and that this deficit was more apparent in the left visual field. Conversely, patients with left hemispheric lesions tended to show impairment on perception of visually presented verbal material when the input was delivered to the right visual field.
Andrews, J S; Jansen, J H; Linders, S; Princen, A; Broekkamp, C L
1995-04-01
The performance of four strains of rats commonly used in behavioural research was assessed in three different tests of learning and memory. The four strains included three outbred lines (Long-Evans, Sprague-Dawley, Wistar) and one inbred strain (S3). Learning and memory were tested using three different paradigms: autoshaping of a lever press, a two-object discrimination test, and performance in a two-island swim maze task. The pigmented strains showed better performance in the autoshaping procedure: the majority of the Long-Evans and the S3 rats acquired the response, and the majority of the Wistar and Sprague-Dawley failed to acquire the response in the set time. The albino strains were slightly better in the swim maze than the pigmented strains. There appeared to be a speed/accuracy trade-off in the strategy used to solve the task. This was also evident following treatment with the cholinergic-depleting agent hemicholinium-3. The performance of the Long-Evans rats was most affected by the treatment in terms of accuracy and the Wistar and Sprague-Dawleys in terms of speed. In the two-object discrimination test only the Long-Evans showed satisfactory performance and were able to discriminate a novel from a known object a short interval after initial exposure. These results show large task- and strain-dependent differences in performance in tests of learning and memory. Some of the performance variation may be due to emotional differences between the strains and may be alleviated by extra training. However, the response to pharmacological manipulation may require more careful evaluation.(ABSTRACT TRUNCATED AT 250 WORDS)
Weihing, Jeffrey; Guenette, Linda; Chermak, Gail; Brown, Mallory; Ceruti, Julianne; Fitzgerald, Krista; Geissler, Kristin; Gonzalez, Jennifer; Brenneman, Lauren; Musiek, Frank
2015-01-01
Although central auditory processing disorder (CAPD) test battery performance has been examined in adults with neurologic lesions of the central auditory nervous system (CANS), similar data on children being referred for CAPD evaluations are sparse. This study characterizes CAPD test battery performance in children using tests commonly administered to diagnose the disorder. Specifically, this study describes failure rates for various test combinations, relationships between CAPD tests used in the battery, and the influence of cognitive function on CAPD test performance and CAPD diagnosis. A comparison is also made between the performance of children with CAPD and data from patients with neurologic lesions of the CANS. A retrospective study. Fifty-six pediatric patients were referred for CAPD testing. Participants were administered four CAPD tests, including frequency patterns (FP), low-pass filtered speech (LPFS), dichotic digits (DD), and competing sentences (CS). In addition, they were given the Wechsler Intelligence Scale for Children (WISC). Descriptive analyses examined the failure rates of various test combinations, as well as how often children with CAPD failed certain combinations when compared with adults with CANS lesions. A principal components analysis was performed to examine interrelationships between tests. Correlations and regressions were conducted to determine the relationship between CAPD test performance and the WISC. Results showed that the FP and LPFS tests were most commonly failed by children with CAPD. Two-test combinations that included one or both of these two tests and excluded DD tended to be failed more often. Including the DD and CS test in a battery benefited specificity. Tests thought to measure interhemispheric transfer tended to be correlated. Compared with adult patients with neurologic lesions, children with CAPD tended to fail LPFS more frequently and DD less frequently. Both groups failed FP with relatively equal frequency. The two-test combination that showed the highest failure rate for children with CAPD was LPFS-FP. Comparison with adults with CANS lesions, however, suggests that the mechanisms underlying LPFS performance in children need to be better understood. The two-test combination that showed the next highest failure rates among children with CAPD and did not include LPFS was CS-FP. If it is desirable to use a dichotic measure that has a lower linguistic load than CS then DD can be substituted for CS despite the slightly lower failure rate of the DD-FP battery. American Academy of Audiology.
Silicon Carbide Diodes Performance Characterization and Comparison With Silicon Devices
NASA Technical Reports Server (NTRS)
Lebron-Velilla, Ramon C.; Schwarze, Gene E.; Trapp, Scott
2003-01-01
Commercially available silicon carbide (SiC) Schottky diodes from different manufacturers were electrically tested and characterized at room temperature. Performed electrical tests include steady state forward and reverse I-V curves, as well as switching transient tests performed with the diodes operating in a hard switch dc-to-dc buck converter. The same tests were performed in current state of the art silicon (Si) and gallium arsenide (GaAs) Schottky and pn junction devices for evaluation and comparison purposes. The SiC devices tested have a voltage rating of 200, 300, and 600 V. The comparison parameters are forward voltage drop at rated current, reverse current at rated voltage and peak reverse recovery currents in the dc to dc converter. Test results show that steady state characteristics of the tested SiC devices are not superior to the best available Si Schottky and ultra fast pn junction devices. Transient tests reveal that the tested SiC Schottky devices exhibit superior transient behavior. This is more evident at the 300 and 600 V rating where SiC Schottky devices showed drastically lower reverse recovery currents than Si ultra fast pn diodes of similar rating.
Predicting the clinical performance of dental students with a manual dexterity test
Lugassy, Diva; Levanon, Yafi; Pilo, Raphael; Shelly, Asaf; Rosen, Gal; Meirowitz, Avi
2018-01-01
Dentists must be skilled when using dental mirrors. Working with mirrors requires spatial perception, bimanual coordination, perceptual learning and fine motor skills. Many studies have attempted to determine the predictors of manual skills among pre-clinical students, but consensus has yet to be reached. We hypothesized that valid and reliable occupational therapy test performance regarding indirect vision would differ between dental students and junior dentists and would explain the variance in manual skill performance in pre-clinical courses. To test this hypothesis, we applied the Purdue Pegboard test and O’Connor Tweezer Dexterity test under different conditions of direct and indirect vision. We administered these tests to students in phantom-head academic courses in 2015 and 2016 and to junior dentists. Students performed the tests at three time points: before phantom training (T0), at the end of the training (T1) and in the middle of the following year of study (T2). Dentists performed the same tests twice at 1st and 2nd trials one week apart. The results showed that indirect tasks were significantly more difficult to perform for both groups. These dexterity tests were sensitive enough to detect students’ improvement after phantom training. The dentists’ performances were significantly better than those of students at T0, specifically with regard to the use of tweezers under direct and indirect vision (the O’Connor test). A regression analysis showed that students’ manual grades obtained at the beginning of the phantom course, their performance on the Purdue test using both hands, and their performance on the O’Connor test under indirect vision predicted phantom course success in 80% of cases. The O’Connor test under indirect vision is the most informative means of monitoring and predicting the manual skills required in the pre-clinical year of dentistry studies. PMID:29518127
Performance of rapid tests and algorithms for HIV screening in Abidjan, Ivory Coast.
Loukou, Y G; Cabran, M A; Yessé, Zinzendorf Nanga; Adouko, B M O; Lathro, S J; Agbessi-Kouassi, K B T
2014-01-01
Seven rapid diagnosis tests (RDTs) of HIV were evaluated by a panel group who collected serum samples from patients in Abidjan (HIV-1 = 203, HIV-2 = 25, HIV-dual = 25, HIV = 305). Kit performances were recorded after the reference techniques (enzyme-linked immunosorbent assay). The following RDTs showed a sensitivity of 100% and a specificity higher than 99%: Determine, Oraquick, SD Bioline, BCP, and Stat-Pak. These kits were used to establish infection screening strategies. The combination with 2 or 3 of these tests in series or parallel algorithms showed that series combinations with 2 tests (Oraquick and Bioline) and 3 tests (Determine, BCP, and Stat-Pak) gave the best performances (sensitivity, specificity, positive predictive value, and negative predictive value of 100%). However, the combination with 2 tests appeared to be more onerous than the combination with 3 tests. The combination with Determine, BCP, and Stat-Pak tests serving as a tiebreaker could be an alternative to the HIV/AIDS serological screening in Abidjan.
Tinnitus and Cognitive Interference: A Stroop Paradigm Study.
ERIC Educational Resources Information Center
Andersson, Gerhard; Eriksson, Jan; Lundh, Lars-Gunnar; Lyttkens, Leif
2000-01-01
This study examined the performance of 23 tinnitus patients on three versions of the Stroop color-word test. Results showed that tinnitus patients performed significantly slower than controls on all test conditions. Results suggest that tinnitus patients have impaired cognitive performance overall, possibly confounded by hearing impairment.…
Vadapalli, Sriharsha Babu; Atluri, Kaleswararao; Putcha, Madhu Sudhan; Kondreddi, Sirisha; Kumar, N. Suman; Tadi, Durga Prasad
2016-01-01
Objectives: This in vitro study was designed to compare polyvinyl-siloxane (PVS) monophase and polyether (PE) monophase materials under dry and moist conditions for properties such as surface detail reproduction, dimensional stability, and gypsum compatibility. Materials and Methods: Surface detail reproduction was evaluated using two criteria. Dimensional stability was evaluated according to American Dental Association (ADA) specification no. 19. Gypsum compatibility was assessed by two criteria. All the samples were evaluated, and the data obtained were analyzed by a two-way analysis of variance (ANOVA) and Pearson's Chi-square tests. Results: When surface detail reproduction was evaluated with modification of ADA specification no. 19, both the groups under the two conditions showed no significant difference statistically. When evaluated macroscopically both the groups showed statistically significant difference. Results for dimensional stability showed that the deviation from standard was significant among the two groups, where Aquasil group showed significantly more deviation compared to Impregum group (P < 0.001). Two conditions also showed significant difference, with moist conditions showing significantly more deviation compared to dry condition (P < 0.001). The results of gypsum compatibility when evaluated with modification of ADA specification no. 19 and by giving grades to the casts for both the groups and under two conditions showed no significant difference statistically. Conclusion: Regarding dimensional stability, both impregum and aquasil performed better in dry condition than in moist; impregum performed better than aquasil in both the conditions. When tested for surface detail reproduction according to ADA specification, under dry and moist conditions both of them performed almost equally. When tested according to macroscopic evaluation, impregum and aquasil performed significantly better in dry condition compared to moist condition. In dry condition, both the materials performed almost equally. In moist condition, aquasil performed significantly better than impregum. Regarding gypsum compatibility according to ADA specification, in dry condition both the materials performed almost equally, and in moist condition aquasil performed better than impregum. When tested by macroscopic evaluation, impregum performed better than aquasil in both the conditions. PMID:27583217
Vadapalli, Sriharsha Babu; Atluri, Kaleswararao; Putcha, Madhu Sudhan; Kondreddi, Sirisha; Kumar, N Suman; Tadi, Durga Prasad
2016-01-01
This in vitro study was designed to compare polyvinyl-siloxane (PVS) monophase and polyether (PE) monophase materials under dry and moist conditions for properties such as surface detail reproduction, dimensional stability, and gypsum compatibility. Surface detail reproduction was evaluated using two criteria. Dimensional stability was evaluated according to American Dental Association (ADA) specification no. 19. Gypsum compatibility was assessed by two criteria. All the samples were evaluated, and the data obtained were analyzed by a two-way analysis of variance (ANOVA) and Pearson's Chi-square tests. When surface detail reproduction was evaluated with modification of ADA specification no. 19, both the groups under the two conditions showed no significant difference statistically. When evaluated macroscopically both the groups showed statistically significant difference. Results for dimensional stability showed that the deviation from standard was significant among the two groups, where Aquasil group showed significantly more deviation compared to Impregum group (P < 0.001). Two conditions also showed significant difference, with moist conditions showing significantly more deviation compared to dry condition (P < 0.001). The results of gypsum compatibility when evaluated with modification of ADA specification no. 19 and by giving grades to the casts for both the groups and under two conditions showed no significant difference statistically. Regarding dimensional stability, both impregum and aquasil performed better in dry condition than in moist; impregum performed better than aquasil in both the conditions. When tested for surface detail reproduction according to ADA specification, under dry and moist conditions both of them performed almost equally. When tested according to macroscopic evaluation, impregum and aquasil performed significantly better in dry condition compared to moist condition. In dry condition, both the materials performed almost equally. In moist condition, aquasil performed significantly better than impregum. Regarding gypsum compatibility according to ADA specification, in dry condition both the materials performed almost equally, and in moist condition aquasil performed better than impregum. When tested by macroscopic evaluation, impregum performed better than aquasil in both the conditions.
Keller, Johannes
2007-06-01
Stereotype threat research revealed that negative stereotypes can disrupt the performance of persons targeted by such stereotypes. This paper contributes to stereotype threat research by providing evidence that domain identification and the difficulty level of test items moderate stereotype threat effects on female students' maths performance. The study was designed to test theoretical ideas derived from stereotype threat theory and assumptions outlined in the Yerkes-Dodson law proposing a nonlinear relationship between arousal, task difficulty and performance. Participants were 108 high school students attending secondary schools. Participants worked on a test comprising maths problems of different difficulty levels. Half of the participants learned that the test had been shown to produce gender differences (stereotype threat). The other half learned that the test had been shown not to produce gender differences (no threat). The degree to which participants identify with the domain of maths was included as a quasi-experimental factor. Maths-identified female students showed performance decrements under conditions of stereotype threat. Moreover, the stereotype threat manipulation had different effects on low and high domain identifiers' performance depending on test item difficulty. On difficult items, low identifiers showed higher performance under threat (vs. no threat) whereas the reverse was true in high identifiers. This interaction effect did not emerge on easy items. Domain identification and test item difficulty are two important factors that need to be considered in the attempt to understand the impact of stereotype threat on performance.
NASA Technical Reports Server (NTRS)
Levinthal, E. C.; Payne, R. O.
1971-01-01
The design and construction of a system to automatically test HLP antigens are described. Major efforts were made to test and evaluate the performance of such a system, and compare its performance with nonautomatic tissue typing techniques. The system is based on the fluorochromatic cytotoxicity assay. Results show the system will work but is subject to malfunctions after a few samplings, and poses problems in showing correctly the necessary readings.
Spatial recognition test: A novel cognition task for assessing topographical memory in mice.
Havolli, Enes; Hill, Mark Dw; Godley, Annie; Goetghebeur, Pascal Jd
2017-06-01
Dysfunction in topographical memory is a core feature of several neurological disorders. There is a large unmet medical need to address learning and memory deficits as a whole in central nervous system disease. There are considerable efforts to identify pro-cognitive compounds but current methods are either lengthy or labour intensive. Our test used a two chamber apparatus and is based on the preference of rodents to explore novel environments. It was used firstly to assess topographical memory in mice at different retention intervals (RI) and secondly to investigate the effect of three drugs reported to be beneficial for cognitive decline associated with Alzheimer's disease, namely: donepezil, memantine and levetiracetam. Animals show good memory performance at all RIs tested under four hours. At the four-hour RI, animals show a significantly poorer memory performance which can be rescued using donepezil, memantine and levetiracetam. Using this test we established and validated a spatial recognition paradigm to address topographical memory in mice by showing a decremental time-induced forgetting response and reversing this decrease in performance using pharmacological tools. The spatial recognition test differs from more commonly used visuospatial laboratory tests in both throughput capability and potentially neuroanatomical substrate. This test has the potential to be used to assess cognitive performance in transgenic animals, disease models and to screen putative cognitive enhancers or depressors.
Litster, Annette L
2014-08-01
Conflicting accounts have been published in the veterinary literature regarding transmission of feline immunodeficiency virus (FIV) between cohabiting cats in mixed households, and the mechanics of possible casual transmission, if it occurs, are poorly understood. Similarly, there are conflicting reports of vertical transmission of FIV. The aim of the present study was to document the FIV serological status of cats taken into two rescue shelters. At rescue shelter 1 (Rescue 1), cats cohabited in a multi-cat household of FIV-negative and naturally-infected, FIV-positive cats. A study was performed that combined a retrospective review of records of FIV serological status at intake (Test 1) and prospective FIV serological testing (Tests 2 and 3). Retrospective records were analyzed at rescue shelter 2 (Rescue 2), where FIV-positive queens with litters of nursing kittens were taken into the shelter, before being rehomed. FIV serology was performed on all kittens after weaning. Initial test results (Test 1) for 138 cohabiting cats from Rescue 1 showed that there were 130 FIV-negative cats and eight FIV-positive cats (six male neutered and two female spayed). A second test (Test 2), performed in 45 of the FIV-negative and five of the FIV-positive cats at median 28 months after Test 1 (range, 1 month to 8.8 years) showed that results were unchanged. Similarly, a third test (Test 3), performed in four of the original FeLV-negative cats and one remaining FIV-positive cat at median 38 months after Test 1 (range, 4 months to 4 years), also showed that results were unchanged. These results show a lack of evidence of FIV transmission, despite years of exposure to naturally-infected, FIV-positive cats in a mixed household. At Rescue 2, records were available from five FIV-positive queens with 19 kittens. All 19 kittens tested FIV-negative, suggesting that vertical transmission had not occurred. Copyright © 2014 Elsevier Ltd. All rights reserved.
RECENT ADVANCES IN HIGH TEMPERATURE ELECTROLYSIS AT IDAHO NATIONAL LABORATORY: SINGLE CELL TESTS
DOE Office of Scientific and Technical Information (OSTI.GOV)
X. Zhang; J. E. O'Brien; R. C. O'Brien
2012-07-01
An experimental investigation on the performance and durability of single solid oxide electrolysis cells (SOECs) is under way at the Idaho National Laboratory. In order to understand and mitigate the degradation issues in high temperature electrolysis, single SOECs with different configurations from several manufacturers have been evaluated for initial performance and long-term durability. A new test apparatus has been developed for single cell and small stack tests from different vendors. Single cells from Ceramatec Inc. show improved durability compared to our previous stack tests. Single cells from Materials and Systems Research Inc. (MSRI) demonstrate low degradation both in fuel cellmore » and electrolysis modes. Single cells from Saint Gobain Advanced Materials (St. Gobain) show stable performance in fuel cell mode, but rapid degradation in the electrolysis mode. Electrolyte-electrode delamination is found to have significant impact on degradation in some cases. Enhanced bonding between electrolyte and electrode and modification of the microstructure help to mitigate degradation. Polarization scans and AC impedance measurements are performed during the tests to characterize the cell performance and degradation.« less
NASA Technical Reports Server (NTRS)
Mulavara, A. P.; Batson, C. D.; Buxton, R. E.; Feiveson, A. H.; Kofman, I. S.; Lee, S. M. C.; Miller, C. A.; Peters, B. T.; Phillips, T.; Platts, S. H.;
2014-01-01
The goal of the Functional Task Test study is to determine the effects of space flight on functional tests that are representative of high priority exploration mission tasks and to identify the key underlying physiological factors that contribute to decrements in performance. We are currently conducting studies on both International Space Station (ISS) astronauts experiencing up to 6 months of microgravity and subjects experiencing 70 days of 6??head-down bed-rest as an analog for space flight. Bed-rest provides the opportunity for us to investigate the role of prolonged axial body unloading in isolation from the other physiological effects produced by exposure to the microgravity environment of space flight. This allows us to parse out the contribution of the body unloading somatosensory component on functional performance. Both ISS crewmembers and bed-rest subjects were tested using a protocol that evaluated functional performance along with tests of postural and locomotor control before and after space flight and bed-rest, respectively. Functional tests included ladder climbing, hatch opening, jump down, manual manipulation of objects and tool use, seat egress and obstacle avoidance, recovery from a fall, and object translation tasks. Astronauts were tested three times before flight, and on 1, 6, and 30 days after landing. Bed-rest subjects were tested three times before bed-rest and immediately after getting up from bed-rest as well as 1, 6, and 12 days after re-ambulation. A comparison of bed-rest and space flight data showed a significant concordance in performance changes across all functional tests. Tasks requiring a greater demand for dynamic control of postural equilibrium (i.e. fall recovery, seat egress/obstacle avoidance during walking, object translation, jump down) showed the greatest decrement in performance. Functional tests with reduced requirements for postural stability showed less reduction in performance. Results indicate that body unloading resulting from prolonged bed-rest impacts functional performance particularly for tests with a greater requirement for postural equilibrium control. These changes in functional performance were paralleled by similar decrement in tests designed to specifically assess postural equilibrium and dynamic gait control. These results indicate that body support unloading experienced during space flight plays a central role in postflight alteration of functional task performance. These data also support the concept that space flight may cause central adaptation of converging body-load somatosensory and vestibular input during gravitational transitions.
Rocket-Based Combined Cycle Flowpath Testing for Modes 1 and 4
NASA Technical Reports Server (NTRS)
Rice, Tharen
2002-01-01
Under sponsorship of the NASA Glenn Research Center (NASA GRC), the Johns Hopkins University Applied Physics Laboratory (JHU/APL) designed and built a five-inch diameter, Rocket-Based Combined Cycle (RBCC) engine to investigate mode 1 and mode 4 engine performance as well as Mach 4 inlet performance. This engine was designed so that engine area and length ratios were similar to the NASA GRC GTX engine is shown. Unlike the GTX semi-circular engine design, the APL engine is completely axisymmetric. For this design, a traditional rocket thruster was installed inside of the scramjet flowpath, along the engine centerline. A three part test series was conducted to determine Mode I and Mode 4 engine performance. In part one, testing of the rocket thruster alone was accomplished and its performance determined (average Isp efficiency = 90%). In part two, Mode 1 (air-augmented rocket) testing was conducted at a nominal chamber pressure-to-ambient pressure ratio of 100 with the engine inlet fully open. Results showed that there was neither a thrust increment nor decrement over rocket-only thrust during Mode 1 operation. In part three, Mode 4 testing was conducted with chamber pressure-to-ambient pressure ratios lower than desired (80 instead of 600) with the inlet fully closed. Results for this testing showed a performance decrease of 20% as compared to the rocket-only testing. It is felt that these results are directly related to the low pressure ratio tested and not the engine design. During this program, Mach 4 inlet testing was also conducted. For these tests, a moveable centerbody was tested to determine the maximum contraction ratio for the engine design. The experimental results agreed with CFD results conducted by NASA GRC, showing a maximum geometric contraction ratio of approximately 10.5. This report details the hardware design, test setup, experimental results and data analysis associated with the aforementioned tests.
NASA Technical Reports Server (NTRS)
Theologus, G. C.; Wheaton, G. R.; Mirabella, A.; Brahlek, R. E.
1973-01-01
A set of 36 relatively independent categories of human performance were identified. These categories encompass human performance in the cognitive, perceptual, and psychomotor areas, and include diagnostic measures and sensitive performance metrics. Then a prototype standardized test battery was constructed, and research was conducted to obtain information on the sensitivity of the tests to stress, the sensitivity of selected categories of performance degradation, the time course of stress effects on each of the selected tests, and the learning curves associated with each test. A research project utilizing a three factor partially repeated analysis of covariance design was conducted in which 60 male subjects were exposed to variations in noise level and quality during performance testing. Effects of randomly intermittent noise on performance of the reaction time tests were observed, but most of the other performance tests showed consistent stability. The results of 14 analyses of covariance of the data taken from the performance of the 60 subjects on the prototype standardized test battery provided information which will enable the final development and test of a standardized test battery and the associated development of differential sensitivity metrics and diagnostic classificatory system.
Test Results for Entry Guidance Methods for Space Vehicles
NASA Technical Reports Server (NTRS)
Hanson, John M.; Jones, Robert E.
2004-01-01
There are a number of approaches to advanced guidance and control that have the potential for achieving the goals of significantly increasing reusable launch vehicle (or any space vehicle that enters an atmosphere) safety and reliability, and reducing the cost. This paper examines some approaches to entry guidance. An effort called Integration and Testing of Advanced Guidance and Control Technologies has recently completed a rigorous testing phase where these algorithms faced high-fidelity vehicle models and were required to perform a variety of representative tests. The algorithm developers spent substantial effort improving the algorithm performance in the testing. This paper lists the test cases used to demonstrate that the desired results are achieved, shows an automated test scoring method that greatly reduces the evaluation effort required, and displays results of the tests. Results show a significant improvement over previous guidance approaches. The two best-scoring algorithm approaches show roughly equivalent results and are ready to be applied to future vehicle concepts.
Test Results for Entry Guidance Methods for Reusable Launch Vehicles
NASA Technical Reports Server (NTRS)
Hanson, John M.; Jones, Robert E.
2003-01-01
There are a number of approaches to advanced guidance and control (AG&C) that have the potential for achieving the goals of significantly increasing reusable launch vehicle (RLV) safety and reliability, and reducing the cost. This paper examines some approaches to entry guidance. An effort called Integration and Testing of Advanced Guidance and Control Technologies (ITAGCT) has recently completed a rigorous testing phase where these algorithms faced high-fidelity vehicle models and were required to perform a variety of representative tests. The algorithm developers spent substantial effort improving the algorithm performance in the testing. This paper lists the test cases used to demonstrate that the desired results are achieved, shows an automated test scoring method that greatly reduces the evaluation effort required, and displays results of the tests. Results show a significant improvement over previous guidance approaches. The two best-scoring algorithm approaches show roughly equivalent results and are ready to be applied to future reusable vehicle concepts.
NASA Astrophysics Data System (ADS)
da Silva, Roberto; Lamb, Luis C.; Barbosa, Marcia C.
2016-09-01
We analyze the scores obtained by students who have taken the ENEM examination, The Brazilian High School National Examination which is used in the admission process at Brazilian universities. The average high schools scores from different disciplines are compared through the Pearson correlation coefficient. The results show a very large correlation between the performance in the different school subjects. Even though the students' scores in the ENEM form a Gaussian due to the standardization, we show that the high schools' scores form a bimodal distribution that cannot be used to evaluate and compare students performance over time. We also show that this high schools distribution reflects the correlation between school performance and the economic level (based on the average family income) of the students. The ENEM scores are compared with a Brazilian non standardized exam, the entrance examination from the Universidade Federal do Rio Grande do Sul. The analysis of the performance of the same individuals in both tests shows that the two tests not only select different abilities, but also lead to the admission of different sets of individuals. Our results indicate that standardized tests might be an interesting tool to compare performance of individuals over the years, but not of institutions.
Nicholson, Brad; O'Hare, David
2014-01-01
Situational awareness is recognised as an important factor in the performance of individuals and teams in dynamic decision-making (DDM) environments (Salmon et al. 2014 ). The present study was designed to investigate whether the scores on the WOMBAT™ Situational Awareness and Stress Tolerance Test (Roscoe and North 1980 ) would predict the transfer of DDM performance from training under different levels of cognitive load to a novel situation. Participants practised a simulated firefighting task under either low or high conditions of cognitive load and then performed a (transfer) test in an alternative firefighting environment under an intermediate level of cognitive load. WOMBAT™ test scores were a better predictor of DDM performance than scores on the Raven Matrices. Participants with high WOMBAT™ scores performed better regardless of their training condition. Participants with recent gaming experience who practised under low cognitive load showed better practice phase performance but worse transfer performance than those who practised under high cognitive load. The relationship between task experience, situational awareness ability, cognitive load and the transfer of dynamic decision-making (DDM) performance was investigated. Results showed that the WOMBAT™ test predicted transfer of DDM performance regardless of task cognitive load. The effects of cognitive load on performance varied according to previous task-relevant experience.
Intervention program efficacy for spelling difficulties.
Sampaio, Maria Nobre; Capellini, Simone Aparecida
2014-01-01
To develop an intervention procedure for spelling difficulties and to verify the effectiveness of the intervention program in students with lower spelling performance. We developed an intervention program for spelling difficulties, according to the semiology of the errors. The program consisted of three modules totaling 16 sessions. The study included 40 students of the third to fifth grade of public elementary education of the city of Marilia (SP), of both genders, in aged of eight to 12 years old, being distributed in the following groups: GI (20 students with lower spelling performance) and GII (20 students with higher spelling performance). In situation of pre and post-testing, all groups were submitted to the Pro-Orthography. The results statistically analyzed showed that, in general, all groups had average of right that has higher in post-testing, reducing the types of errors second semiologycal classification, mainly related to natural spelling errors. However, the results also showed that the groups submitted to the intervention program showed better performance on spelling tests in relation to not submitted. The intervention program developed was effective once the groups submitted showed better performance on spelling tests in relation to not submitted. Therefore, the intervention program can help professionals in the Health and Education to minimize the problems related to spelling, giving students an intervention that is effective for the development of the spelling knowledge.
Hong, Hye Jeong; Kim, Jin Sung; Seo, Wan Seok; Koo, Bon Hoon; Bai, Dai Seg; Jeong, Jin Young
2010-01-01
Objective We investigated executive functions (EFs), as evaluated by the Wisconsin Card Sorting Test (WCST), and other EF between lower grades (LG) and higher grades (HG) in elementary-school-age attention deficit hyperactivity disorder (ADHD) children. Methods We classified a sample of 112 ADHD children into 4 groups (composed of 28 each) based on age (LG vs. HG) and WCST performance [lower vs. higher performance on WCST, defined by the number of completed categories (CC)] Participants in each group were matched according to age, gender, ADHD subtype, and intelligence. We used the Wechsler intelligence Scale for Children 3rd edition to test intelligence and the Computerized Neurocognitive Function Test-IV, which included the WCST, to test EF. Results Comparisons of EFs scores in LG ADHD children showed statistically significant differences in performing digit spans backward, some verbal learning scores, including all memory scores, and Stroop test scores. However, comparisons of EF scores in HG ADHD children did not show any statistically significant differences. Correlation analyses of the CC and EF variables and stepwise multiple regression analysis in LG ADHD children showed a combination of the backward form of the Digit span test and Visual span test in lower-performance ADHD participants significantly predicted the number of CC (R2=0.273, p<0.001). Conclusion This study suggests that the design of any battery of neuropsychological tests for measuring EF in ADHD children should first consider age before interpreting developmental variations and neuropsychological test results. Researchers should consider the dynamics of relationships within EF, as measured by neuropsychological tests. PMID:20927306
Selective, sustained, and shift in attention in patients with diagnoses of schizophrenia.
Hagh-Shenas, H; Toobai, S; Makaremi, A
2002-12-01
Attentional deficits are a prominent aspect of cognitive dysfunction in schizophrenia. The present study was designed to investigate attention deficit in a group of patients with diagnosis of schizophrenia. According to the segmental set theory suggested by Hogarty and Flesher, three aspects of attention problems, selective, sustained, and shift in attention, were studied. The 30 patients hospitalized on three psychiatric wards at Shiraz and Isfahan and 30 normal healthy subjects matched for age, sex, and years of education were administered a computerized Continuous Performance Test, Stroop Color-word Test, and Wisconsin Card Sorting test. Analysis showed patients performed more poorly than control subjects on measured aspects of attention. The acute/chronic classification did not predict differences in attention scores between subtypes of schizophrenia, while the positive/negative classification did. Paranoid, undifferentiated, and residual groups by subtypes of schizophrenia showed similar performance on the Continuous Performance Test, but were significantly different on errors on the Wisconsin Card Sorting test and on reaction time to Stroop stimuli in the incongruent color-word condition. Patients with paranoid diagnosis performed better than other subtypes on these tasks. Present results suggest that the Continuous Performance Test is valuable for differentiating of schizophrenia spectrum disorder, while scores on Stroop and Wisconsin card sorting may have better diagnostic value for differentiating subtypes of the disorder.
Accuracy of simple urine tests for diagnosis of urinary tract infections in low-risk pregnant women.
Feitosa, Danielle Cristina Alves; da Silva, Márcia Guimarães; de Lima Parada, Cristina Maria Garcia
2009-01-01
Anatomic and physiological alterations during pregnancy predispose pregnant women to urinary tract infections (UTI). This study aimed to identify the accuracy of the simple urine test for UTI diagnosis in low-risk pregnant women. Diagnostic test performance was conducted in Botucatu, SP, involving 230 pregnant women, between 2006 and 2008. Results showed 10% UTI prevalence. Sensitivity, specificity and accuracy of the simple urine test were 95.6%, 63.3% and 66.5%, respectively, in relation to UTI diagnoses. The analysis of positive (PPV) and negative (NPV) predictive values showed that, when a regular simple urine test was performed, the chance of UTI occurrence was small (NPV 99.2%). In view of an altered result for such a test, the possibility of UTI existence was small (PPV 22.4%). It was concluded that the accuracy of the simple urine test as a diagnostic means for UTI was low, and that performing a urine culture is essential for appropriate diagnosis.
Rapid Methods for Biochemical Testing of Anaerobic Bacteria
Schreckenberger, Paul C.; Blazevic, Donna J.
1974-01-01
Rapid biochemical tests for nitrate, indole, gelatin, starch, esculin, and o-nitrophenyl-β-D-galactopyranoside were performed on 112 strains of anaerobic bacteria. All tests were incubated under aerobic conditions, and results were recorded within 4 h. The tests for nitrate, indole, and starch showed a 95% or greater correlation when compared to the standard biochemical tests. Tests for esculin and gelatin showed an agreement of 86 and 77%, respectively. PathoTec test strips for nitrate, indole, esculin, o-nitrophenyl-β-D-galactopyranoside, Voges-Proskauer, and urease were also tested and showed encouraging results. PMID:4613268
Vasconcelos-Moreno, Mirela P; Bücker, Joana; Bürke, Kelen P; Czepielewski, Leticia; Santos, Barbara T; Fijtman, Adam; Passos, Ives C; Kunz, Mauricio; Bonnín, Caterina Del Mar; Vieta, Eduard; Kapczinski, Flavio; Rosa, Adriane R; Kauer-Sant'Anna, Marcia
2016-01-01
To assess cognitive performance and psychosocial functioning in patients with bipolar disorder (BD), in unaffected siblings, and in healthy controls. Subjects were patients with BD (n=36), unaffected siblings (n=35), and healthy controls (n=44). Psychosocial functioning was accessed using the Functioning Assessment Short Test (FAST). A sub-group of patients with BD (n=21), unaffected siblings (n=14), and healthy controls (n=22) also underwent a battery of neuropsychological tests: California Verbal Learning Test (CVLT), Stroop Color and Word Test, and Wisconsin Card Sorting Test (WCST). Clinical and sociodemographic characteristics were analyzed using one-way analysis of variance or the chi-square test; multivariate analysis of covariance was used to examine differences in neuropsychological variables. Patients with BD showed higher FAST total scores (23.90±11.35) than healthy controls (5.86±5.47; p < 0.001) and siblings (12.60±11.83; p 0.001). Siblings and healthy controls also showed statistically significant differences in FAST total scores (p = 0.008). Patients performed worse than healthy controls on all CVLT sub-tests (p < 0.030) and in the number of correctly completed categories on WCST (p = 0.030). Siblings did not differ from healthy controls in cognitive tests. Unaffected siblings of patients with BD may show poorer functional performance compared to healthy controls. FAST scores may contribute to the development of markers of vulnerability and endophenotypic traits in at-risk populations.
Embedded Figures Test Performance in the Broader Autism Phenotype: A Meta-Analysis
ERIC Educational Resources Information Center
Cribb, Serena J.; Olaithe, Michelle; Di Lorenzo, Renata; Dunlop, Patrick D.; Maybery, Murray T.
2016-01-01
People with autism show superior performance to controls on the Embedded Figures Test (EFT). However, studies examining the relationship between autistic-like traits and EFT performance in neurotypical individuals have yielded inconsistent findings. To examine the inconsistency, a meta-analysis was conducted of studies that (a) compared high and…
Rubio-Arias, Jacobo Ángel; Ramos Campo, Domingo Jesús; Ruiloba Nuñez, Juana María; Carrasco Poyatos, María; Alcaraz Ramón, Pedro Emilio; Jiménez Díaz, Fernando José
2015-05-01
Low energy intake may lead to the loss of muscle mass, menstrual dysfunction, increased risk of fatigue, injures and the need for prolonged recovery process. 1) To analyse the adherence to the Mediterranean diet of a elite female athletes futsal population, 2) To analyse the relationship between the Dietary Mediterranean index, body composition and sport performance, and 3) To analyse if the differences in the index of adherence to the Mediterranean diet generates test differences in sports performance and body composition. The adherence to a Mediterranean Diet, body composition test, isokinetic test, vertical jump test (CMJ and SJ), kicking ball, speed test and test Repeated Sprint Ability (RSA) was measured. we found that 7 out of 12 players (58.33%) showed a low index and 5 of the 12 players (41.67%) showed a means index. We found that 7 out of 12 players (58.33%) showed a low index and 5 of the 12 players (41.67%) below the optimum index. Moreover, this adhesion index did not correlate with the values of the body composition or athletic performance test. No significant differences between the players that scored below the optimal index with those with a low level of adhesion were observed. However, mass fat (%) correlated to the ability to repeat sprint. Low levels of adherence to the Mediterranean diet was observed in futsal players, the values shown in the KIDMED questionnaire did not correlate with the performance of the players nor body composition. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Physical examination for lumbar radiculopathy due to disc herniation in patients with low-back pain.
van der Windt, Daniëlle Awm; Simons, Emmanuel; Riphagen, Ingrid I; Ammendolia, Carlo; Verhagen, Arianne P; Laslett, Mark; Devillé, Walter; Deyo, Rick A; Bouter, Lex M; de Vet, Henrica Cw; Aertgeerts, Bert
2010-02-17
Low-back pain with leg pain (sciatica) may be caused by a herniated intervertebral disc exerting pressure on the nerve root. Most patients will respond to conservative treatment, but in carefully selected patients, surgical discectomy may provide faster relief of symptoms. Primary care clinicians use patient history and physical examination to evaluate the likelihood of disc herniation and select patients for further imaging and possible surgery. (1) To assess the performance of tests performed during physical examination (alone or in combination) to identify radiculopathy due to lower lumbar disc herniation in patients with low-back pain and sciatica;(2) To assess the influence of sources of heterogeneity on diagnostic performance. We searched electronic databases for primary studies: PubMed (includes MEDLINE), EMBASE, and CINAHL, and (systematic) reviews: PubMed and Medion (all from earliest until 30 April 2008), and checked references of retrieved articles. We considered studies if they compared the results of tests performed during physical examination on patients with back pain with those of diagnostic imaging (MRI, CT, myelography) or findings at surgery. Two review authors assessed the quality of each publication with the QUADAS tool, and extracted details on patient and study design characteristics, index tests and reference standard, and the diagnostic two-by-two table. We presented information on sensitivities and specificities with 95% confidence intervals (95% CI) for all aspects of physical examination. Pooled estimates of sensitivity and specificity were computed for subsets of studies showing sufficient clinical and statistical homogeneity. We included 16 cohort studies (median N = 126, range 71 to 2504) and three case control studies (38 to100 cases). Only one study was carried out in a primary care population. When used in isolation, diagnostic performance of most physical tests (scoliosis, paresis or muscle weakness, muscle wasting, impaired reflexes, sensory deficits) was poor. Some tests (forward flexion, hyper-extension test, and slump test) performed slightly better, but the number of studies was small. In the one primary care study, most tests showed higher specificity and lower sensitivity compared to other settings.Most studies assessed the Straight Leg Raising (SLR) test. In surgical populations, characterized by a high prevalence of disc herniation (58% to 98%), the SLR showed high sensitivity (pooled estimate 0.92, 95% CI: 0.87 to 0.95) with widely varying specificity (0.10 to 1.00, pooled estimate 0.28, 95% CI: 0.18 to 0.40). Results of studies using imaging showed more heterogeneity and poorer sensitivity. The crossed SLR showed high specificity (pooled estimate 0.90, 95% CI: 0.85 to 0.94) with consistently low sensitivity (pooled estimate 0.28, 95% CI: 0.22 to 0.35).Combining positive test results increased the specificity of physical tests, but few studies presented data on test combinations. When used in isolation, current evidence indicates poor diagnostic performance of most physical tests used to identify lumbar disc herniation. However, most findings arise from surgical populations and may not apply to primary care or non-selected populations. Better performance may be obtained when tests are combined.
Performance of a distributed superscalar storage server
NASA Technical Reports Server (NTRS)
Finestead, Arlan; Yeager, Nancy
1993-01-01
The RS/6000 performed well in our test environment. The potential exists for the RS/6000 to act as a departmental server for a small number of users, rather than as a high speed archival server. Multiple UniTree Disk Server's utilizing one UniTree Disk Server's utilizing one UniTree Name Server could be developed that would allow for a cost effective archival system. Our performance tests were clearly limited by the network bandwidth. The performance gathered by the LibUnix testing shows that UniTree is capable of exceeding ethernet speeds on an RS/6000 Model 550. The performance of FTP might be significantly faster if asked to perform across a higher bandwidth network. The UniTree Name Server also showed signs of being a potential bottleneck. UniTree sites that would require a high ratio of file creations and deletions to reads and writes would run into this bottleneck. It is possible to improve the UniTree Name Server performance by bypassing the UniTree LibUnix Library altogether and communicating directly with the UniTree Name Server and optimizing creations. Although testing was performed in a less than ideal environment, hopefully the performance statistics stated in this paper will give end-users a realistic idea as to what performance they can expect in this type of setup.
INTEGRATED PROTECTIVE FABRIC SYSTEM (IPFS) PHASE III PROGRAM: AEROSOL PROTECTION REPORT
2017-08-16
one layer control. It was observed that aerosol swatch measurements showed no correlation to aerosol system test performance for the materials and...the BRHA model employed. It was observed that aerosol swatch measurements showed no correlation to aerosol system test performance for the...Testing” (McVeety et al., 2015). This report includes a description of the materials and material controls, a description of the IPFS configurations
Prince, John; Arora, Siddharth; de Vos, Maarten
2018-04-26
To better understand the longitudinal characteristics of Parkinson's disease (PD) through the analysis of finger tapping and memory tests collected remotely using smartphones. Using a large cohort (312 PD subjects and 236 controls) of participants in the mPower study, we extract clinically validated features from a finger tapping and memory test to monitor the longitudinal behaviour of study participants. We investigate any discrepancy in learning rates associated with motor and non-motor tasks between PD subjects and healthy controls. The ability of these features to predict self-assigned severity measures is assessed whilst simultaneously inspecting the severity scoring system for floor-ceiling effects. Finally, we study the relationship between motor and non-motor longitudinal behaviour to determine if separate aspects of the disease are dependent on one another. We find that the test performances of the most severe subjects show significant correlations with self-assigned severity measures. Interestingly, less severe subjects do not show significant correlations, which is shown to be a consequence of floor-ceiling effects within the mPower self-reporting severity system. We find that motor performance after practise is a better predictor of severity than baseline performance suggesting that starting performance at a new motor task is less representative of disease severity than the performance after the test has been learnt. We find PD subjects show significant impairments in motor ability as assessed through the alternating finger tapping (AFT) test in both the short- and long-term analyses. In the AFT and memory tests we demonstrate that PD subjects show a larger degree of longitudinal performance variability in addition to requiring more instances of a test to reach a steady state performance than healthy subjects. Our findings pave the way forward for objective assessment and quantification of longitudinal learning rates in PD. This can be particularly useful for symptom monitoring and assessing medication response. This study tries to tackle some of the major challenges associated with self-assessed severity labels by designing and validating features extracted from big datasets in PD, which could help identify digital biomarkers capable of providing measures of disease severity outside of a clinical environment.
Modelling tooth–prey interactions in sharks: the importance of dynamic testing
Farina, Stacy C.; Brash, Jeffrey; Summers, Adam P.
2016-01-01
The shape of shark teeth varies among species, but traditional testing protocols have revealed no predictive relationship between shark tooth morphology and performance. We developed a dynamic testing device to quantify cutting performance of teeth. We mimicked head-shaking behaviour in feeding large sharks by attaching teeth to the blade of a reciprocating power saw fixed in a custom-built frame. We tested three tooth types at biologically relevant speeds and found differences in tooth cutting ability and wear. Teeth from the bluntnose sixgill (Hexanchus griseus) showed poor cutting ability compared with tiger (Galeocerdo cuvier), sandbar (Carcharhinus plumbeus) and silky (C. falciformis) sharks, but they also showed no wear with repeated use. Some shark teeth are very sharp at the expense of quickly dulling, while others are less sharp but dull more slowly. This demonstrates that dynamic testing is vital to understanding the performance of shark teeth. PMID:27853592
Woodworth, K Nina; Palmateer, Julie; Swide, Joseph; Grafe, Marjorie R
2011-10-01
Until recently, supplementation with 100% oxygen was standard therapy for newborns who required resuscitation at birth or suffered later hypoxic-ischemic events. Exposure to high concentrations of oxygen, however, may worsen oxidative stress induced by ischemic injury. In this study we investigated the short- and long-term behavioral outcomes in rats that had undergone hypoxic-ischemic brain injury on postnatal day 7, followed by 2h exposure to 21%, 40%, or 100% oxygen, compared to normal controls. There were no differences in the development of walking, head lifting and righting reflexes from postnatal days 9 to 15. Cliff avoidance showed some abnormal responses in the H21 animals. From postnatal days 28 to 56, three tests of sensorimotor coordination were performed weekly: ledged tapered beam, cylinder, and bilateral tactile stimulation. The ledged tapered beam test without prior training of animals was sensitive to injury, but did not distinguish between treatment groups. The cylinder test showed a greater use of the unimpaired limb in female 21% and 40% oxygen groups compared to controls. Performance in both cylinder and the beam tests showed a correlation with the degree of brain injury. The bilateral tactile stimulation test showed that the male 21% oxygen groups had worse sensory asymmetry than male 40% or 100% oxygen groups, but was not statistically significantly different from controls. We thus found a minor benefit to post-hypoxia-ischemic treatment with 100% and 40% oxygen compared to 21% in one test of early motor skills. Our results for long-term sensorimotor behavior, however, showed conflicting results, however, as males treated with 40% or 100% oxygen had less sensory asymmetry (better performance) in the bilateral tactile stimulation test than males treated with 21% oxygen, while females had impaired motor performance in the cylinder test with both 21% and 40% oxygen. Copyright © 2011 ISDN. Published by Elsevier Ltd. All rights reserved.
Pileggi, Claudia; Flotta, Domenico; Bianco, Aida; Nobile, Carmelo G A; Pavia, Maria
2014-07-01
Human-papillomavirus (HPV) DNA testing has been proposed as an alternative to primary cervical cancer screening using cytological testing. Review of the evidence shows that available data are conflicting for some aspects. The overall goal of the study is to update the performance of HPV DNA as stand-alone testing in primary cervical cancer screening, focusing particularly on the aspects related to the specificity profile of the HPV DNA testing in respect to cytology. We performed a meta-analysis of randomized controlled clinical trials. Eight articles were included in the meta-analysis. Three outcomes have been investigated: relative detection, relative specificity, and relative positive predictive value (PPV) of HPV DNA testing versus cytology. Overall evaluation of relative detection showed a significantly higher detection of CIN2+ and CIN3+ for HPV DNA testing versus cytology. Meta-analyses that considered all age groups showed a relative specificity that favored the cytology in detecting both CIN2+ and CIN3+ lesions whereas, in the ≥30 years' group, specificity of HPV DNA and cytology tests was similar in detecting both CIN2+ and CIN3+ lesions. Results of the pooled analysis on relative PPV showed a not significantly lower PPV of HPV DNA test over cytology. A main key finding of the study is that in women aged ≥30, has been found an almost overlapping specificity between the two screening tests in detecting CIN2 and above-grade lesions. Therefore, primary screening of cervical cancer by HPV DNA testing appears to offer the right balance between maximum detection of CIN2+ and adequate specificity, if performed in the age group ≥30 years. © 2013 UICC.
Affordable Electro-Magnetic Interference (EMI) Testing on Large Space Vehicles
NASA Technical Reports Server (NTRS)
Aldridge, Edward; Curry, Bruce; Scully, Robert
2015-01-01
Objective: Perform System-Level EMI testing of the Orion Exploration Flight Test-1 (EFT-1) spacecraft in situ in the Kennedy Space Center's Neil Armstrong Operations & Checkout (O&C) Facility in 6 days. The only way to execute the system-level EMI testing and meet this schedule challenge was to perform the EMI testing in situ in the Final Assembly & System Test (FAST) Cell in a reverberant mode, not the direct illumination mode originally planned. This required the unplanned construction of a Faraday Cage around the vehicle and FAST Cell structure. The presence of massive steel platforms created many challenges to developing an efficient screen room to contain the RF energy and yield an effective reverberant chamber. An initial effectiveness test showed marginal performance, but improvements implemented afterward resulted in the final test performing surprisingly well! The paper will explain the design, the challenges, and the changes that made the difference in performance!
de Witte, Annemarie M H; Hoozemans, Marco J M; Berger, Monique A M; van der Slikke, Rienk M A; van der Woude, Lucas H V; Veeger, Dirkjan H E J
2018-01-01
The aim of this study was to develop and describe a wheelchair mobility performance test in wheelchair basketball and to assess its construct validity and reliability. To mimic mobility performance of wheelchair basketball matches in a standardised manner, a test was designed based on observation of wheelchair basketball matches and expert judgement. Forty-six players performed the test to determine its validity and 23 players performed the test twice for reliability. Independent-samples t-tests were used to assess whether the times needed to complete the test were different for classifications, playing standards and sex. Intraclass correlation coefficients (ICC) were calculated to quantify reliability of performance times. Males performed better than females (P < 0.001, effect size [ES] = -1.26) and international men performed better than national men (P < 0.001, ES = -1.62). Performance time of low (≤2.5) and high (≥3.0) classification players was borderline not significant with a moderate ES (P = 0.06, ES = 0.58). The reliability was excellent for overall performance time (ICC = 0.95). These results show that the test can be used as a standardised mobility performance test to validly and reliably assess the capacity in mobility performance of elite wheelchair basketball athletes. Furthermore, the described methodology of development is recommended for use in other sports to develop sport-specific tests.
Performance of the Lester battery charger in electric vehicles
NASA Technical Reports Server (NTRS)
Vivian, H. C.; Bryant, J. A.
1984-01-01
Tests are performed on an improved battery charger. The primary purpose of the testing is to develop test methodologies for battery charger evaluation. Tests are developed to characterize the charger in terms of its charge algorithm and to assess the effects of battery initial state of charge and temperature on charger and battery efficiency. Tests show this charger to be a considerable improvement in the state of the art for electric vehicle chargers.
Issa, Amine N; Herman, Nicole M; Wentz, Robert J; Taylor, Bryan J; Summerfield, Doug C; Johnson, Bruce D
2016-09-01
It is well documented that cognitive performance may be altered with ascent to altitude, but the association of various cognitive performance tests with symptoms of acute mountain sickness (AMS) is not well understood. Our objective was to assess and compare cognitive performance during a high-altitude expedition using several tests and to report the association of each test with AMS, headache, and quality of sleep. During an expedition to Mount Everest, 3 cognitive tests (Stroop, Trail Making, and the real-time cognitive assessment tool, an in-house developed motor accuracy test) were used along with a questionnaire to assess health and AMS. Eight team members were assessed pre-expedition, postexpedition, and at several time points during the expedition. There were no significant differences (P >.05) found among scores taken at 3 time points at base camp and the postexpedition scores for all 3 tests. Changes in the Stroop test scores were significantly associated with the odds of AMS (P <.05). The logistic regression results show that the percent change from baseline for Stroop score (β = -5.637; P = .032) and Stroop attempts (β = -5.269; P = .049) are significantly associated with the odds of meeting the criteria for AMS. No significant changes were found in overall cognitive performance at altitude, but a significant relationship was found between symptoms of AMS and performance in certain cognitive tests. This research shows the need for more investigation of objective physiologic assessments to associate with self-perceived metrics of AMS to gauge effect on cognitive performance. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.
Effect of gender on the hearing performance of adult cochlear implant patients.
Lenarz, Minoo; Sönmez, Hasibe; Joseph, Gert; Büchner, Andreas; Lenarz, Thomas
2012-05-01
To evaluate the role of gender on the hearing performance of postlingually deafened adult patients with cochlear implants. Individual retrospective cohort study. There were 638 postlingually deafened adults (280 men and 358 women) selected for a retrospective evaluation of their hearing performance with cochlear implants. Both genders underwent the same surgical and rehabilitative procedures and benefited from the latest technological advances available. There was no significant difference in the age, duration of deafness, and preoperative hearing performance between the genders. The test battery was composed of the Freiburger Monosyllabic Test, Speech Tracking, and the Hochmair-Schulz-Moser (HSM) sentence test in quiet and in 10-dB noise. The results of 5 years of follow-up are presented here. Genders showed a similar performance in Freiburger Monosyllabic Test and Speech Tracking Test. However, in the HSM test in noise, men performed slightly better than women in all of the follow-up sessions, which was statistically significant at 2 and 4 years after implantation. Although normal-hearing women use more predictive cognitive strategies in speech comprehension and are supposed to have a more efficient declarative memory system, this may not necessarily lead to a better adaptation to the altered auditory information delivered by a cochlear implant. Our study showed that in more complex listening situations such as speech tests in noise, men tend to perform slightly better than women. Gender may have an influence on the hearing performance of postlingually deafened adults with cochlear implants. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.
Meijer, Joost; Oostdam, Ron
2007-03-01
The influence of test anxiety and the content of instruction (stressful versus reassuring) on measurements of intelligence were investigated. It was expected that components of test anxiety would show differential effects on test performance. A Latin Square design was used to unravel the effects of test type and test order. Furthermore, effects of type of instruction, stressful versus reassuring, were studied by means of a within-subjects design. Test anxiety was measured with the Revised Worry-Emotionality Questionnaire. Measurements for verbal ability, reasoning, and memory were administered. Performance on memory tests showed less vulnerability to test anxiety compared with the other tests, with a picture recall test being insensitive. The negative effect of test anxiety was mostly confined to the beginning of a test session, independent of the type of test. Partial support for the so-called stage-fright hypothesis was found. The effect of instructional content was equivocal.
Ryan, Denise S; Sia, Rose K; Stutzman, Richard D; Pasternak, Joseph F; Howard, Robin S; Howell, Christopher L; Maurer, Tana; Torres, Mark F; Bower, Kraig S
2017-01-01
To compare visual performance, marksmanship performance, and threshold target identification following wavefront-guided (WFG) versus wavefront-optimized (WFO) photorefractive keratectomy (PRK). In this prospective, randomized clinical trial, active duty U.S. military Soldiers, age 21 or over, electing to undergo PRK were randomized to undergo WFG (n = 27) or WFO (n = 27) PRK for myopia or myopic astigmatism. Binocular visual performance was assessed preoperatively and 1, 3, and 6 months postoperatively: Super Vision Test high contrast, Super Vision Test contrast sensitivity (CS), and 25% contrast acuity with night vision goggle filter. CS function was generated testing at five spatial frequencies. Marksmanship performance in low light conditions was evaluated in a firing tunnel. Target detection and identification performance was tested for probability of identification of varying target sets and probability of detection of humans in cluttered environments. Visual performance, CS function, marksmanship, and threshold target identification demonstrated no statistically significant differences over time between the two treatments. Exploratory regression analysis of firing range tasks at 6 months showed no significant differences or correlations between procedures. Regression analysis of vehicle and handheld probability of identification showed a significant association with pretreatment performance. Both WFG and WFO PRK results translate to excellent and comparable visual and military performance. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.
Face distinctiveness and delayed testing: differential effects on performance and confidence.
Metzger, Mitchell M
2006-04-01
The author investigated the effect of delayed testing on participants' memory for distinctive and typical faces. Participants viewed distinctive and typical faces and were then tested for recognition immediately or after a delay of 3, 6, or 12 weeks. Consistent with prior research, analysis of measure of sensitivity (d') showed that participants performed better on distinctive rather than typical faces, and memory performance declined with longer retention intervals between study and testing. Furthermore, the superior performance on distinctive faces had vanished by the 12-week test. Contrary to d' data, however, an analysis of confidence scores indicated that participants were still significantly more confident on trials depicting distinctive faces, even with a 12-week delay between study and recognition testing.
Dincer D'Alessandro, Hilal; Filipo, Roberto; Ballantyne, Deborah; Attanasio, Giuseppe; Bosco, Ersilia; Nicastri, Maria; Mancini, Patrizia
2015-11-01
The aim of the present study was to investigate the application of two new pitch perception tests in children with cochlear implants (CI) and to compare CI outcomes to normal hearing (NH) children, as well as investigating the effect of chronological age on performance. The tests were believed to be linked to the availability of Temporal Fine Structure (TFS) cues. 20 profoundly deaf children with CI (5-17 years) and 31 NH peers participated in the study. Harmonic Intonation (HI) and Disharmonic Intonation (DI) tests were used to measure low-frequency pitch perception. HI/DI outcomes were found poorer in children with CI. CI and NH groups showed a statistically significant difference (p < 0.001). HI scores were better than those of DI test (p < 0.001). Chronological age had a significant effect on DI performance in NH group (p < 0.05); children under the age of 8.5 years showed larger inter-subject-variability; however, the majority of NH children showed outcomes that were considered normal at adult-level. For the DI test, bimodal listeners had better performance than when listening with CI alone. HI/DI tests were applicable as clinical tools in the pediatric population. The majority of CI users showed abnormal outcomes on both tests confirming poor TFS processing in the hearing-impaired population. Findings indicated that the DI test provided more differential low-frequency pitch perception outcomes in that it reflected phase locking and TFS processing capacities of the ear, whereas HI test provided information of its place coding capacity as well.
[Neuropsychological modifications at high altitude: from Pamir to Karakorum].
Nardi, Bernardo; Brandoni, Marco; Capecci, Ilaria; Castellani, Simona; Rupoli, Sara; Bellantuono, Cesario
2009-01-01
Neuropsychological modifications and acclimatization processes at over 8000 without auxiliary oxygen were investigated in two climbers, evaluating attentive abilities and matching their performances. During rest in base-camp (4800 m), at other three Resorts - Resort I (5800 m), Resort II (6400 m), Resort III (7200 m) -, and four months after the return at low altitude, were administered: Temporal Orientation Test (TOT), Trail Making Test (TMT), Animal Naming (AN), Verbal Fluency Test (VFT), Arithmetical Judgment Test (AJT), and Drawing Test (DT). Results. At TOT and at AJT, both the climbers demonstrated scores at higher normal levels (Eq = 4) in all the Resorts in which they were performed. They showed an impairment at AN test, especially at Resort III, showing sensitivity of animal naming to hypoxia. At the DT, human figures were reduced in their dimensions and details, as consequence of the tendency to self closure and introversion that occurs at higher altitudes. Neuropsychological functions concerning verbal fluency showed sensitivity to hypoxia, especially at higher altitudes. TMT demonstrated that attentive ability can be preserved if acclimatization is good. Sensitivity to hypoxia and acclimatization processes showed a significant subjective variability. The results of this study show that exposure to high altitude produces some significant neuropsychological changes.
Diagnostic methods for CW laser damage testing
NASA Astrophysics Data System (ADS)
Stewart, Alan F.; Shah, Rashmi S.
2004-06-01
High performance optical coatings are an enabling technology for many applications - navigation systems, telecom, fusion, advanced measurement systems of many types as well as directed energy weapons. The results of recent testing of superior optical coatings conducted at high flux levels will be presented. The diagnostics used in this type of nondestructive testing and the analysis of the data demonstrates the evolution of test methodology. Comparison of performance data under load to the predictions of thermal and optical models shows excellent agreement. These tests serve to anchor the models and validate the performance of the materials and coatings.
Energy Efficient Engine core design and performance report
NASA Technical Reports Server (NTRS)
Stearns, E. Marshall
1982-01-01
The Energy Efficient Engine (E3) is a NASA program to develop fuel saving technology for future large transport aircraft engines. Testing of the General Electric E3 core showed that the core component performance and core system performance necessary to meet the program goals can be achieved. The E3 core design and test results are described.
Application of Rasch Measurement to a Measure of Musical Performance.
ERIC Educational Resources Information Center
Haley, Kathleen A.
1999-01-01
Describes the Rasch calibration of a portion of the Watkins Farnum Performance Scale (J. Watkins and S. Farnum, 1954), a test of instructional music performance, for 218 sixth graders. Results show how Rasch scaling allows item difficulties to be estimated, the test to be administered more efficiently, and diagnostic information to be obtained.…
Heparin-Induced Thrombocytopenia Antibody Test
... HIT II is clinically suspected. There is a pre-test scoring system that is typically used to determine ... The HIT antibody test is performed when this pre-scoring test shows that a person has a moderate to ...
Assessment of surface hardness of acrylic resins submitted to accelerated artificial aging.
Tornavoi, D C; Agnelli, J A M; Lepri, C P; Mazzetto, M O; Botelho, A L; Soares, R G; Dos Reis, A C
2012-06-01
The aim of this study was to assess the influence of accelerated artificial aging (AAA) on the surface hardness of acrylic resins. The following three commercial brands of acrylic resins were tested: Vipi Flash (autopolymerized resin), Vipi Wave (microwave heat-polymerized resin) and Vipi Cril (conventional heat-polymerized resin). To perform the tests, 21 test specimens (65x10x3 mm) were made, 7 for each resin. Three surface hardness readings were performed for each test specimen, before and after AAA, and the means were submitted to the following tests: Kolmogorov-Smirnov (P>0.05), Levene Statistic, Two-way ANOVA, Tukey Post Hoc (P<0.05) with the SPSS Statistical Software 17.0. The analysis of the factors showed significant differences in the hardness values (P<0.05). Before aging, the autopolymerized acrylic resin Vipi Flash showed lower hardness values when compared with the heat-polymerized resin Vipi Cril (P=0.001). After aging, the 3 materials showed similar performance when compared among them. The Vipi Cril was the only one affected by AAA and showed lower hardness values after this procedure (Pp=0.003). It may be concluded that accelerated artificial aging influenced surface hardness of heat-polymerized acrylic resin Vipi Cril.
Hwang, S H; Yi, T W; Cho, K H; Lee, I M; Yoon, C S
2011-09-01
To test a performance of the microbiological safety cabinets (MSCs) according to the type of MSCs in microbial laboratories. Tests were carried out to assess the performance of 31 MSCs in 14 different facilities, including six different biological test laboratories in six hospitals and eight different laboratories in three universities. The following tests were performed on the MSCs: the downflow test, intake velocity test, high-efficiency particulate air filter leak test and the airflow smoke pattern test. These performance tests were carried out in accordance with the standard procedures. Only 23% of Class II A1 (8), A2 (19) and unknown MSCs (4) passed these performance tests. The main reasons for the failure of MSCs were inappropriate intake velocity (65%), leakage in the HEPA filter sealing (50%), unbalanced airflow smoke pattern in the cabinets (39%) and inappropriate downflow (27%). This study showed that routine checks of MSCs are important to detect and strengthen the weak spots that frequently develop, as observed during the evaluation of the MSCs of various institutions. Routine evaluation and maintenance of MSCs are critical for optimizing performance. © 2011 The Authors. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.
NASA Astrophysics Data System (ADS)
Hallal, P. B.; Bis, R. F.
1986-08-01
The developmental EMATT (expendable, mobile, ASW training target) may use a high-energy (lithium/sulfuryl chloride) battery system. Safety problems with the original battery cell design were experienced during early performance and safety testing. After redesign of the battery cell, performance and safety tests were made under specified abuse conditions, as well as under simulated launch conditions. The test results showed that the power system now meets all safety requirements, and that the EMATT vehicle is safe to deploy for its engineering development phase.
Application of a Brazilian test of expressive vocabulary in European Portuguese children.
Cáceres-Assenço, Ana Manhani; Ferreira, Sandra Cristina Araújo; Santos, Anabela Cruz; Befi-Lopes, Debora Maria
2018-01-01
Objective to investigate the performance of European Portuguese children in a Brazilian test of expressive vocabulary, seeking to identify differences between age groups and gender, and to verify its applicability in this population. Methods the sample consisted of 150 typical developed children, of both genders, between the ages of 5 and 6. All children attended public schools in the north area of Portugal. To assess the semantic performance, the expressive vocabulary sub-test of the language test (ABFW) was used, considering the percentage of usual verbal assignments and the classification (adequate/inadequate) according to the Brazilian reference values. Results the performance of the European Portuguese children indicated that at age 6 they have a higher percentage of correct answers in expressive vocabulary. As for the gender, there were only occasional differences: the girls showed a greater dominance in the semantic fields of clothing (both ages) and furniture and utensils (at age 5), whereas the boys showed more dominance in the semantic field means of transportation (6 years). Regarding classification, there was no difference between age groups in overall performance. Only the semantic field shapes and colors had more individuals of 6 years with inadequate performance. Conclusion the reference values adopted in the Brazilian population for semantic performance indicated that more than 80% of the children of each age group could have their performance classified as adequate. Such evidence suggests that this tool shows potential as an instrument of quantitative vocabulary's assessment of 5 and 6-years old children in European Portuguese.
Balogun, Anthony Gbenro; Balogun, Shyngle Kolawole; Onyencho, Chidi Victor
2017-02-13
This study investigated the moderating role of achievement motivation in the relationship between test anxiety and academic performance. Three hundred and ninety three participants (192 males and 201 females) selected from a public university in Ondo State, Nigeria using a purposive sampling technique, participated in the study. They responded to measures of test anxiety and achievement motivation. Three hypotheses were tested using moderated hierarchical multiple regression analysis. Results showed that test anxiety had a negative impact on academic performance (β = -.23; p < .05). Achievement motivation had a positive impact on academic performance (β = .38; p < .05). Also, achievement motivation significantly moderated the relationship between test anxiety and academic performance (β = .10; p < .01). These findings suggest that university management should design appropriate psycho-educational interventions that would enhance students' achievement motivation.
Uebbing, Lukas; Klumpp, Lukas; Webster, Gregory K; Löbenberg, Raimar
2017-01-01
Drug product performance testing is an important part of quality-by-design approaches, but this process often lacks the underlying mechanistic understanding of the complex interactions between the disintegration and dissolution processes involved. Whereas a recent draft guideline by the US Food and Drug Administration (FDA) has allowed the replacement of dissolution testing with disintegration testing, the mentioned criteria are not globally accepted. This study provides scientific justification for using disintegration testing rather than dissolution testing as a quality control method for certain immediate release (IR) formulations. A mechanistic approach, which is beyond the current FDA criteria, is presented. Dissolution testing via United States Pharmacopeial Convention Apparatus II at various paddle speeds was performed for immediate and extended release formulations of metronidazole. Dissolution profile fitting via DDSolver and dissolution profile predictions via DDDPlus™ were performed. The results showed that Fickian diffusion and drug particle properties (DPP) were responsible for the dissolution of the IR tablets, and that formulation factors (eg, coning) impacted dissolution only at lower rotation speeds. Dissolution was completely formulation controlled if extended release tablets were tested and DPP were not important. To demonstrate that disintegration is the most important dosage form attribute when dissolution is DPP controlled, disintegration, intrinsic dissolution and dissolution testing were performed in conventional and disintegration impacting media (DIM). Tablet disintegration was affected by DIM and model fitting to the Korsmeyer-Peppas equation showed a growing effect of the formulation in DIM. DDDPlus was able to predict tablet dissolution and the intrinsic dissolution profiles in conventional media and DIM. The study showed that disintegration has to occur before DPP-dependent dissolution can happen. The study suggests that disintegration can be used as performance test of rapidly disintegrating tablets beyond the FDA criteria. The scientific criteria and justification is that dissolution has to be DPP dependent, originated from active pharmaceutical ingredient characteristics and formulations factors have to be negligible.
Uebbing, Lukas; Klumpp, Lukas; Webster, Gregory K; Löbenberg, Raimar
2017-01-01
Drug product performance testing is an important part of quality-by-design approaches, but this process often lacks the underlying mechanistic understanding of the complex interactions between the disintegration and dissolution processes involved. Whereas a recent draft guideline by the US Food and Drug Administration (FDA) has allowed the replacement of dissolution testing with disintegration testing, the mentioned criteria are not globally accepted. This study provides scientific justification for using disintegration testing rather than dissolution testing as a quality control method for certain immediate release (IR) formulations. A mechanistic approach, which is beyond the current FDA criteria, is presented. Dissolution testing via United States Pharmacopeial Convention Apparatus II at various paddle speeds was performed for immediate and extended release formulations of metronidazole. Dissolution profile fitting via DDSolver and dissolution profile predictions via DDDPlus™ were performed. The results showed that Fickian diffusion and drug particle properties (DPP) were responsible for the dissolution of the IR tablets, and that formulation factors (eg, coning) impacted dissolution only at lower rotation speeds. Dissolution was completely formulation controlled if extended release tablets were tested and DPP were not important. To demonstrate that disintegration is the most important dosage form attribute when dissolution is DPP controlled, disintegration, intrinsic dissolution and dissolution testing were performed in conventional and disintegration impacting media (DIM). Tablet disintegration was affected by DIM and model fitting to the Korsmeyer–Peppas equation showed a growing effect of the formulation in DIM. DDDPlus was able to predict tablet dissolution and the intrinsic dissolution profiles in conventional media and DIM. The study showed that disintegration has to occur before DPP-dependent dissolution can happen. The study suggests that disintegration can be used as performance test of rapidly disintegrating tablets beyond the FDA criteria. The scientific criteria and justification is that dissolution has to be DPP dependent, originated from active pharmaceutical ingredient characteristics and formulations factors have to be negligible. PMID:28442890
Custodio, Nilton; Alva-Diaz, Carlos; Becerra-Becerra, Yahaira; Montesinos, Rosa; Lira, David; Herrera-Pérez, Eder; Castro-Suárez, Sheila; Cuenca-Alfaro, José; Valeriano-Lorenzo, Elizabeth
2016-01-01
Evaluate the performance of clock drawing test- Manos versión (PDR-M) and Mini Mental State Examination -Peruvian version (MMSE) to detect dementia in a sample based on urban community of Lima, Peru. This study is a secondary analysis database, observational, analytical and cross-sectional, the gold standard was the clinical and the neuropsychological evaluations together. Performance testing individually and in combination were evaluated.. Data were obtained from prevalence study conducted in 2008 in Cercado de Lima. MMSE performance for evaluation of patients with dementia of any kind showed sensitivity of 64,1%, specificity of 84,1%, PPV of 24.4%, NPV of 96.7%, PLR of 4,03 and NLR of 0,43. PDR-M showed sensitivity of 89,3%, specificity of 98,1%, PPV of 79.3%, NPV of 99.1%, PLR of 47,79 and NLR of 0,11. When both tests were applied, and at least one of them was positive, they showed sensitivity 98.1%, specificity 84.1%, PPV of 33.1%, NPV of 99.8%, PLR of 6,17 and NLR of 0,02. When performing separate analysis of Alzheimer-type dementia and non- Alzheimer dementia, the values of the parameters do not differ substantially from those obtained for dementia of any kind. The combination of MMSE and PDR-M show good discriminative ability to detect moderate and severe dementia in population living in urban community in Lima.
Reliability of movement control tests in the lumbar spine
Luomajoki, Hannu; Kool, Jan; de Bruin, Eling D; Airaksinen, Olavi
2007-01-01
Background Movement control dysfunction [MCD] reduces active control of movements. Patients with MCD might form an important subgroup among patients with non specific low back pain. The diagnosis is based on the observation of active movements. Although widely used clinically, only a few studies have been performed to determine the test reliability. The aim of this study was to determine the inter- and intra-observer reliability of movement control dysfunction tests of the lumbar spine. Methods We videoed patients performing a standardized test battery consisting of 10 active movement tests for motor control in 27 patients with non specific low back pain and 13 patients with other diagnoses but without back pain. Four physiotherapists independently rated test performances as correct or incorrect per observation, blinded to all other patient information and to each other. The study was conducted in a private physiotherapy outpatient practice in Reinach, Switzerland. Kappa coefficients, percentage agreements and confidence intervals for inter- and intra-rater results were calculated. Results The kappa values for inter-tester reliability ranged between 0.24 – 0.71. Six tests out of ten showed a substantial reliability [k > 0.6]. Intra-tester reliability was between 0.51 – 0.96, all tests but one showed substantial reliability [k > 0.6]. Conclusion Physiotherapists were able to reliably rate most of the tests in this series of motor control tasks as being performed correctly or not, by viewing films of patients with and without back pain performing the task. PMID:17850669
Neuropsychological sequelae of work-stress-related exhaustion.
Österberg, Kai; Skogsliden, Sofia; Karlson, Björn
2014-01-01
The aim was to assess long-term cognitive performance after substantial recovery from work-stress-related exhaustion, in relation to subjective cognitive complaints and return to active work. In total, 54 patients previously diagnosed with work-stress-related exhaustion participated in a neuropsychological examination ∼2 years after initial sick leave. Most participants were substantially recovered at follow-up, with only 13% still meeting the criteria for exhaustion disorder suggested by the Swedish National Board of Health and Welfare. When participants' scores on 14 neuropsychological tests were compared to a matched group of 50 controls, the former patient group showed lower performance mainly on attention tests of the reaction time type, but also slightly lower scores on visuo-spatial constructional ability. However, the former patient group performed better than controls on two memory tests and, in part, on a test of simultaneous capacity. Self-ratings of everyday cognitive problems remained significantly higher in the former patient group than among controls, but the extent of self-rated cognitive problems was generally unrelated to performance on the neuropsychological tests. No relationship between performance on these tests and the extent of work resumption was observed. In summary, persons with previous work-stress-related exhaustion showed persistent signs of a minor attention deficit, despite considerable general recovery and return to work.
[Comparative study of the performance of leather and plastic skate boots].
Roy, B; Grenier, R
1982-03-01
The authors have tried to demonstrate the influence of leather skate boots and plastic boots on the performance of Atome hockey players. Speed tests and joint flexibility tests by means of rotentgenograms showed that besides the speed tests where the leather boot appeared to perform a little better than the plastic boot, no significant difference could be found between both types of boots. It seems to be more a matter of individual choice and adaptation.
Two-IMU FDI performance of the sequential probability ratio test during shuttle entry
NASA Technical Reports Server (NTRS)
Rich, T. M.
1976-01-01
Performance data for the sequential probability ratio test (SPRT) during shuttle entry are presented. Current modeling constants and failure thresholds are included for the full mission 3B from entry through landing trajectory. Minimum 100 percent detection/isolation failure levels and a discussion of the effects of failure direction are presented. Finally, a limited comparison of failures introduced at trajectory initiation shows that the SPRT algorithm performs slightly worse than the data tracking test.
Thermal Analysis of Low Layer Density Multilayer Insulation Test Results
NASA Technical Reports Server (NTRS)
Johnson, Wesley L.
2011-01-01
Investigation of the thermal performance of low layer density multilayer insulations is important for designing long-duration space exploration missions involving the storage of cryogenic propellants. Theoretical calculations show an analytical optimal layer density, as widely reported in the literature. However, the appropriate test data by which to evaluate these calculations have been only recently obtained. As part of a recent research project, NASA procured several multilayer insulation test coupons for calorimeter testing. These coupons were configured to allow for the layer density to be varied from 0.5 to 2.6 layer/mm. The coupon testing was completed using the cylindrical Cryostat-l00 apparatus by the Cryogenics Test Laboratory at Kennedy Space Center. The results show the properties of the insulation as a function of layer density for multiple points. Overlaying these new results with data from the literature reveals a minimum layer density; however, the value is higher than predicted. Additionally, the data show that the transition region between high vacuum and no vacuum is dependent on the spacing of the reflective layers. Historically this spacing has not been taken into account as thermal performance was calculated as a function of pressure and temperature only; however the recent testing shows that the data is dependent on the Knudsen number which takes into account pressure, temperature, and layer spacing. These results aid in the understanding of the performance parameters of MLI and help to complete the body of literature on the topic.
Fischer, Avi; Klehn, Russell
2013-08-01
The insulation of St. Jude Medical Riata® leads contains a polytetrafluoroethylene (PTFE) liner, silicone tubing, and ethylenetetrafluoroethylene (ETFE) coating on individual cable conductors. ETFE has sufficient dielectric strength to assure electrical function. This investigation intended to analyze performance of leads with and without externalized conductors and with intact and breached ETFE. Testing was performed on ETFE-coated conductors to determine their ability to deliver high-voltage therapy. Tests were performed on samples under different conditions and current leakage was measured. A high-voltage test and a cyclic pulse test were performed, and the effect of lead modifications on the potential gradient from a high-voltage shock was used to determine functionality. Measurements from modified Riata® leads were compared with a control lead with all insulation and conducting elements intact. Current leakage for all conditions tested, was within the acceptance criteria for the high-voltage test and the cyclic pulse test. In conductors that underwent cyclic testing, the highest value of current leakage was within the limit of acceptability for both phases of the test. Testing of leads with externalized conductors and breached ETFE showed similar potential gradients compared with a control lead. Testing of ETFE-coated conductors following multiple preconditioning steps showed that ETFE serves as a redundant layer of insulation. In the event that the ETFE coating is breached, the potential gradient seen resulting from a high-voltage defibrillation shock was similar to a lead with no breach to the ETFE, even after 100 shocks.
Picho, Katherine; Rodriguez, Ariel; Finnie, Lauren
2013-01-01
The current meta-analysis synthesized 17 years of research on stereotype threat (ST). Specifically, it examined the moderating effect of contextual factors on ST. Findings revealed that, on average, females in ST conditions performed less well on mathematics tests than their control counterparts (d =|10.24|). Results also showed that females did not benefit more from female-only testing situations, or testing contexts where they formed the majority. Nevertheless, the trend in ST effects differed by broader contextual factors like geography and level of education, with females in countries with small gender-gaps showing better performance under ST conditions, and ST effects being greater for students in middle and high school compared to college students.
[Genetic aspects of the Stroop test].
Nánási, Tibor; Katonai, Enikő Rózsa; Sasvári-Székely, Mária; Székely, Anna
2012-12-01
Impairment of executive control functions in depression is well documented, and performance on the Stroop Test is one of the most widely used markers to measure the decline. This tool provides reliable quantitative phenotype data that can be used efficiently in candidate gene studies investigating inherited components of executive control. Aim of the present review is to summarize research on genetic factors of Stroop performance. Interestingly, only a few such candidate gene studies have been carried out to date. Twin studies show a 30-60% heritability estimate for the Stroop test, suggesting a significant genetic component. A single genome-wide association study has been carried out on Stroop performance, and it did not show any significant association with any of the tested polymorphisms after correction for multiple testing. Candidate gene studies to date pointed to the polymorphisms of several neurotransmitter systems (dopamine, serotonin, acetylcholine) and to the role of the APOE ε4 allele. Surprisingly, little is known about the genetic role of neurothrophic factors and survival factors. In conclusion, further studies are needed for clarifying the genetic background of Stroop performance, characterizing attentional functions.
Herbst, Daniel P
2014-09-01
Micropore filters are used during extracorporeal circulation to prevent gaseous and solid particles from entering the patient's systemic circulation. Although these devices improve patient safety, limitations in current designs have prompted the development of a new concept in micropore filtration. A prototype of the new design was made using 40-μm filter screens and compared against four commercially available filters for performance in pressure loss and gross air handling. Pre- and postfilter bubble counts for 5- and 10-mL bolus injections in an ex vivo test circuit were recorded using a Doppler ultrasound bubble counter. Statistical analysis of results for bubble volume reduction between test filters was performed with one-way repeated-measures analysis of variance using Bonferroni post hoc tests. Changes in filter performance with changes in microbubble load were also assessed with dependent t tests using the 5- and 10-mL bolus injections as the paired sample for each filter. Significance was set at p < .05. All filters in the test group were comparable in pressure loss performance, showing a range of 26-33 mmHg at a flow rate of 6 L/min. In gross air-handling studies, the prototype showed improved bubble volume reduction, reaching statistical significance with three of the four commercial filters. All test filters showed decreased performance in bubble volume reduction when the microbubble load was increased. Findings from this research support the underpinning theories of a sequential arterial-line filter design and suggest that improvements in microbubble filtration may be possible using this technique.
Herbst, Daniel P.
2014-01-01
Abstract: Micropore filters are used during extracorporeal circulation to prevent gaseous and solid particles from entering the patient’s systemic circulation. Although these devices improve patient safety, limitations in current designs have prompted the development of a new concept in micropore filtration. A prototype of the new design was made using 40-μm filter screens and compared against four commercially available filters for performance in pressure loss and gross air handling. Pre- and postfilter bubble counts for 5- and 10-mL bolus injections in an ex vivo test circuit were recorded using a Doppler ultrasound bubble counter. Statistical analysis of results for bubble volume reduction between test filters was performed with one-way repeated-measures analysis of variance using Bonferroni post hoc tests. Changes in filter performance with changes in microbubble load were also assessed with dependent t tests using the 5- and 10-mL bolus injections as the paired sample for each filter. Significance was set at p < .05. All filters in the test group were comparable in pressure loss performance, showing a range of 26–33 mmHg at a flow rate of 6 L/min. In gross air-handling studies, the prototype showed improved bubble volume reduction, reaching statistical significance with three of the four commercial filters. All test filters showed decreased performance in bubble volume reduction when the microbubble load was increased. Findings from this research support the underpinning theories of a sequential arterial-line filter design and suggest that improvements in microbubble filtration may be possible using this technique. PMID:26357790
Moore, Eric J; Price, Daniel L; Van Abel, Kathryn M; Carlson, Matthew L
2015-02-01
Application to otolaryngology-head and neck surgery residency is highly competitive, and the interview process strives to select qualified applicants with a high aptitude for the specialty. Commonly employed criteria for applicant selection have failed to show correlation with proficiency during residency training. We evaluate the correlation between the results of a surgical aptitude test administered to otolaryngology resident applicants and their performance during residency. Retrospective study at an academic otolaryngology-head and neck surgery residency program. Between 2007 and 2013, 224 resident applicants participated in a previously described surgical aptitude test administered at a microvascular surgical station. The composite score and attitudinal scores for 24 consecutive residents who matched at our institution were recorded, and their residency performance was analyzed by faculty survey on a five-point scale. The composite and attitudinal scores were analyzed for correlation with residency performance score by regression analysis. Twenty-four residents were evaluated for overall quality as a clinician by eight faculty members who were blinded to the results of surgical aptitude testing. The results of these surveys showed good inter-rater reliability. Both the overall aptitude test scores and the subset attitudinal score showed reliability in predicting performance during residency training. The goal of the residency selection process is to evaluate the candidate's potential for success in residency and beyond. The results of this study suggest that a simple-to-administer clinical skills test may have predictive value for success in residency and clinician quality. 4. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.
46 CFR 131.590 - Firefighting equipment.
Code of Federal Regulations, 2010 CFR
2010-10-01
... performance of the tests and inspections of each portable fire extinguisher, semiportable fire extinguisher... master shall keep records of these tests and inspections, showing the dates of their performance, the... maintain the prescribed firefighting equipment in working order for use at any time when the vessel is...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arnold, G.; Nelson, S.; Cooperrider, N.K.
1982-02-11
This report, Volume II, contains the results, conclusions, and recommendations of the first performance test of a transit care on the RDU. This report is limited to performance tests. The objective is to identify advantages and disadvantages of performance testing on the rollers of the RDU as highlighted by the SOAC test. The report involved separate testing, done by TTC personnel, in such traditional performance areas of transit vehicle operation ass traction, acceleration/deceleration, energy consumption, and spin/slide performance. The results of the successful performance test of a transit car on a roller unit is presented and the advantages of thismore » method of testing is discussed. Acceleration, deceleration, spin/slide, and power consumption tests, although of limited scope in comparison to the track tests performed on the same transit car, did show the feasibility of roller testing. It is concluded that the RDU is most suited for developmental testing of transit car systems particularly for power consumption and for cars with non-standard wheel gage. Tests should be of such scope as to justify the cost of car setup on the RDU. The following two test are recommended: (1) a power consumption study for a standard/non-standard gage transit car which investigates methods of reducing power consumption and (2) a non-standard gage full performance test.« less
Motivation and performance in physical education: an experimental test.
Moreno, Juan A; González-Cutre, David; Martín-Albo, José; Cervelló, Eduardo
2010-01-01
The purpose of this study was to analyse, experimentally, the relationships between motivation and performance in a lateral movement test in physical education. The study group consisted of 363 students (227 boys and 136 girls), aged between 12 and 16, who were randomly divided into three groups: an experimental group in which an incremental ability belief was induced, another experimental group in which an entity ability belief was induced, and a control group where there was no intervention. Measurements were made of situational intrinsic motivation, perceived competence in executing the task and performance. The results revealed that the incremental group reported higher scores on the situational intrinsic motivation scale. The entity group demonstrated better performance in the first test attempt than the incremental group but, in the second attempt, the performance was similar in the different groups. Perhaps the initial differences in performance disappeared because the incremental group counted on improving in the second attempt. These results are discussed in relation to the intensity with which the teacher conveys information relating to incremental ability belief of the pupil to increase intrinsic motivation and performance. Key pointsThe incremental group showed more situational intrinsic motivation.The entity group showed higher performance in the first test attempt, but significant differences disappeared in the second attempt.It seems that this incremental belief and greater intrinsic motivation made the students trust they would improve their performance in the second attempt at the lateral movement test.
Chan, Wing-Nga; Tsang, William Wai-Nam
2017-01-01
Turning-while-walking is one of the commonest causes of falls in stroke survivors. It involves cognitive processing and may be challenging when performed concurrently with a cognitive task. Previous studies of dual-tasking involving turning-while-walking in stroke survivors show that the performance of physical tasks is compromised. However, the design of those studies did not address the response of stroke survivors under dual-tasking condition without specifying the task-preference and its effect on the performance of the cognitive task. First, to compare the performance of single-tasking and dual-tasking in stroke survivors. Second, to compare the performance of stroke survivors with non-stroke controls. Fifty-nine stroke survivors and 45 controls were assessed with an auditory Stroop test, a turning-while-walking test, and a combination of the two single tasks. The outcome of the cognitive task was measured by the reaction time and accuracy of the task. The physical task was evaluated by measuring the turning duration, number of steps to turn, and time to complete the turning-while-walking test. Stroke survivors showed a significantly reduced accuracy in the auditory Stroop test when dual-tasking, but there was no change in the reaction time. Their performance in the turning-while-walking task was similar under both single-tasking and dual-tasking condition. Additionally, stroke survivors demonstrated a significantly longer reaction time and lower accuracy than the controls both when single-tasking and dual-tasking. They took longer to turn, with more steps, and needed more time to complete the turning-while-walking task in both tasking conditions. The results show that stroke survivors with high mobility function performed the auditory Stroop test less accurately while preserving simultaneous turning-while-walking performance. They also demonstrated poorer performance in both single-tasking and dual-tasking as compared with controls.
Hot-Fire Testing of a 1N AF-M315E Thruster
NASA Technical Reports Server (NTRS)
Burnside, Christopher G.; Pedersen, Kevin; Pierce, Charles W.
2015-01-01
This hot-fire test continues NASA investigation of green propellant technologies for future missions. To show the potential for green propellants to replace some hydrazine systems in future spacecraft, NASA Marshall Space Flight Center (MSFC) is continuing to embark on hot-fire test campaigns with various green propellant blends. NASA completed a hot-fire test of a 1N AF-M315E monopropellant thruster at the Marshall Space Flight Center in the small altitude test stand located in building 4205. The thruster is a ground test article used for basic performance determination and catalyst studies. The purpose of the hot-fire testing was for performance determination of a 1N size thruster and form a baseline from which to study catalyst performance and life with follow-on testing to be conducted at a later date. The thruster performed as expected. The result of the hot-fire testing are presented in this paper and presentation.
Test report on the model 44000 seismometer system
NASA Astrophysics Data System (ADS)
1988-08-01
Teledyne Geotech has completed long period subsurface vault tests on four individual 44000 modules; two horizontal and two vertical. Each type of module is tested in tandem by comparing the outputs of aligned sensors. The latest data is outstanding, particularly that of the horizontal. At a period of 20 seconds, both vertical and horizontal channels show incoherent noise power of approximately-180 dB relative to 1 (m/sec-sq)sq/Hz. At a period of 64 seconds, the horizontal data is some 20 dB quieter than any previous borehole data and furthermore shows no increase with period, even at periods as long as 250 seconds. This performance is remarkable for a non-borehole installation. The vertical data shows excellent performance, although some temperature effects seem to be present. A detailed explanation of the experimental history and current tests follows.
MOON-test - determination of motor performance in the pediatric oncology.
Götte, M; Kesting, S; Albrecht, C; Worth, A; Bös, K; Boos, J
2013-05-01
Pediatric cancer patients suffer from various negative consequences due to the disease, the medical therapy and the inactivity during the intensive treatment. Only few studies have systematically identified the adverse effects of cancer on motor performance in childhood. To determine the motor performance of pediatric cancer patients, a motor performance test was developed which is applicable for this specific patient group. Eight test items with reference values for healthy children were merged to the MOON-test (test for motor performance in the oncology). MOON was tested for feasibility and acceptance in 33 patients aged 4-18 years. Feasibility was confirmed for children with different types of cancer (hematological malignancies and solid tumors) and with amputation, endoprosthesis, during aplasia as well as reduced general condition. Furthermore the patients showed a broad acceptance. Based on the study findings, the use of MOON-test as a standardized motor performance diagnostic tool in clinical routine of oncological acute clinics as well as rehabilitation clinics can be recommended.· © Georg Thieme Verlag KG Stuttgart · New York.
Performance map of a cluster detection test using extended power
2013-01-01
Background Conventional power studies possess limited ability to assess the performance of cluster detection tests. In particular, they cannot evaluate the accuracy of the cluster location, which is essential in such assessments. Furthermore, they usually estimate power for one or a few particular alternative hypotheses and thus cannot assess performance over an entire region. Takahashi and Tango developed the concept of extended power that indicates both the rate of null hypothesis rejection and the accuracy of the cluster location. We propose a systematic assessment method, using here extended power, to produce a map showing the performance of cluster detection tests over an entire region. Methods To explore the behavior of a cluster detection test on identical cluster types at any possible location, we successively applied four different spatial and epidemiological parameters. These parameters determined four cluster collections, each covering the entire study region. We simulated 1,000 datasets for each cluster and analyzed them with Kulldorff’s spatial scan statistic. From the area under the extended power curve, we constructed a map for each parameter set showing the performance of the test across the entire region. Results Consistent with previous studies, the performance of the spatial scan statistic increased with the baseline incidence of disease, the size of the at-risk population and the strength of the cluster (i.e., the relative risk). Performance was heterogeneous, however, even for very similar clusters (i.e., similar with respect to the aforementioned factors), suggesting the influence of other factors. Conclusions The area under the extended power curve is a single measure of performance and, although needing further exploration, it is suitable to conduct a systematic spatial evaluation of performance. The performance map we propose enables epidemiologists to assess cluster detection tests across an entire study region. PMID:24156765
Effects of Group Gender Composition on Mental Rotation Test Performance in Women.
Moè, Angelica
2018-06-01
Mental rotation is a task in which men outscore women by up to one standard deviation. Many biological, strategic, experiential, and motivational factors concur to explain this gender gap. Among these there are gender stereotypes, which could either harm or favor performance, giving rise, respectively, to stereotype threat or lift effects. This study examined effects due to stereotypes induced by testing women in a minority mixed-gender group composition (subtle message) when provided with instructions about men's or women's superiority (blatant message), in order to assess the hypothesis that the effort of disconfirming a negative stereotype causes increased performance when two messages, either blatant or subtle, are provided. Sixty-six men and 78 women tested either in a mixed-gender or a same-gender group composition were provided with one of the three instructions (men better, women better, nullifying) after performing a mental rotation test (baseline measure) and before taking another one. Results showed that women increased performance mainly when instructed that men score higher in the mixed-gender group composition, and after the nullifying instructions when tested in the same-gender group composition. Men increased performance mainly when they were instructed that women scored higher. Taken together, the results showed that both genders improve performance, when two threats arise both subtly and blatantly, or when no threat is in the air. Effects of implicit and explicit activated stereotypes are discussed.
Takai, Daiya
2014-12-01
Spirometry and the flow-volume curve test are commonly performed lung function tests. However, a unique clinical entity occasionally shows almost normal data in these tests, and is therefore missed on screening tests. The clinical entity of combined pulmonary emphysema and pulmdoary fibrosis was recognized and documented in the 90's in Japan, the USA, and Europe. Typical emphysema shows obstructive disorders, and pulmonary fibrosis shows restrictive disorders. Thus, the combination of both should lead to a combined disorder pattern in lung function tests, but this is not the case. In 2005, Cottin reported and redefined this combination of emphysema and fibrosis of the lung as "Combined Pulmonary Fibrosis and Emphysema" (CPFE). The patients are typically heavily smoking males who show an almost normal lung function. The upper lobe of these patients usually shows severe emphysema, which contributes to a static volume and a late phase in the forced volume test. On the other hand their lower lobe shows fibrotic change. The fibrotic portion contributes to early phase flow in the flow-volume curve. These mechanisms are a reason for the normal pattern appearance in lung function tests in CPFE patients. As a matter of course, these patients have damaged upper and lower lobes: their diffusing capacity of the lung shows a low performance, their saturation of blood hemoglobin decreases soon after light exercise, and their KL-6 (a blood marker of pulmonary fibrosis) usually shows a high value. They are considered a high risk group regarding complications of post-surgical treatment. Thus, when medical technologists identify suspicious cases, they should advise doctors to add diffusing capacity and KL-6 tests. (Review).
Effect of inspiratory muscle warm-up on submaximal rowing performance.
Arend, Mati; Mäestu, Jarek; Kivastik, Jana; Rämson, Raul; Jürimäe, Jaak
2015-01-01
Performing inspiratory muscle warm-up might increase exercise performance. The aim of this study was to investigate the impact of inspiratory muscle warm-up to submaximal rowing performance and to find if there is an effect on lactic acid accumulation and breathing parameters. Ten competitive male rowers aged between 19 and 27 years (age, 23.1 ± 3.8 years; height, 188.1 ± 6.3 cm; body mass, 85.6 ± 6.6 kg) were tested 3 times. During the first visit, maximal inspiratory pressure (MIP) assessment and the incremental rowing test were performed to measure maximal oxygen consumption and maximal aerobic power (Pamax). A submaximal intensity (90% Pamax) rowing test was performed twice with the standard rowing warm-up as test 1 and with the standard rowing warm-up and specific inspiratory muscle warm-up as test 2. During the 2 experimental tests, distance, duration, heart rate, breathing frequency, ventilation, peak oxygen consumption, and blood lactate concentration were measured. The only value that showed a significant difference between the test 1 and test 2 was breathing frequency (52.2 ± 6.8 vs. 53.1 ± 6.8, respectively). Heart rate and ventilation showed a tendency to decrease and increase, respectively, after the inspiratory muscle warm-up (p < 0.1). Despite some changes in respiratory parameters, the use of 40% MIP intensity warm-up is not suggested if the mean intensity of the competition is at submaximal level (at approximately 90% maximal oxygen consumption). In conclusion, the warm-up protocol of the respiratory muscles used in this study does not have a significant influence on submaximal endurance performance in highly trained male rowers.
Preliminary supersonic flight test evaluation of performance seeking control
NASA Technical Reports Server (NTRS)
Orme, John S.; Gilyard, Glenn B.
1993-01-01
Digital flight and engine control, powerful onboard computers, and sophisticated controls techniques may improve aircraft performance by maximizing fuel efficiency, maximizing thrust, and extending engine life. An adaptive performance seeking control system for optimizing the quasi-steady state performance of an F-15 aircraft was developed and flight tested. This system has three optimization modes: minimum fuel, maximum thrust, and minimum fan turbine inlet temperature. Tests of the minimum fuel and fan turbine inlet temperature modes were performed at a constant thrust. Supersonic single-engine flight tests of the three modes were conducted using varied after burning power settings. At supersonic conditions, the performance seeking control law optimizes the integrated airframe, inlet, and engine. At subsonic conditions, only the engine is optimized. Supersonic flight tests showed improvements in thrust of 9 percent, increases in fuel savings of 8 percent, and reductions of up to 85 deg R in turbine temperatures for all three modes. The supersonic performance seeking control structure is described and preliminary results of supersonic performance seeking control tests are given. These findings have implications for improving performance of civilian and military aircraft.
Nitrous oxide as a tracer gas in the ASHRAE 110-1995 Standard.
Burke, Martin; Wong, Larry; Gonzales, Ben A; Knutson, Gerhard
2014-01-01
ANSI/ASHRAE Standard 110 provides a quantitative method for testing the performance of laboratory fume hoods. Through release of a known quantity (4.0 Lpm) of a tracer gas, and subsequent monitoring of the tracer gas concentration in the "breathing zone" of a mannequin positioned in front of the hood, this method allows for evaluation of laboratory hood performance. Standard 110 specifies sulfur hexafluoride (SF6) as the tracer gas; however, suitable alternatives are allowed. Through three series of performance tests, this analysis serves to investigate the use of nitrous oxide (N2O) as an alternate tracer gas for hood performance testing. Single gas tests were performed according to ASHRAE Standard 110-1995 with each tracer gas individually. These tests showed identical results using an acceptance criterion of AU 0.1 with the sash half open, nominal 18 inches (0.46m) high, and the face velocity at a nominal 60 fpm (0.3 m/s). Most data collected in these single gas tests, for both tracer gases, were below the minimum detection limit, thus two dual gas tests were developed for simultaneous sampling of both tracer gases. Dual gas dual ejector tests were performed with both tracer gases released simultaneously through two ejectors, and the concentration measured with two detectors using a common sampling probe. Dual gas single ejector tests were performed with both tracer gases released though a single ejector, and the concentration measured in the same manner as the dual gas dual ejector tests. The dual gas dual ejector tests showed excellent correlation, with R typically greater than 0.9. Variance was observed in the resulting regression line for each hood, likely due to non-symmetry between the two challenges caused by variables beyond the control of the investigators. Dual gas single ejector tests resulted in exceptional correlation, with R>0.99 typically for the consolidated data, with a slope of 1.0. These data indicate equivalent results for ASHRAE 110 performance testing using either SF6 or N2O, indicating N2O as an applicable alternate tracer gas.
40 CFR 60.2720 - May I conduct performance testing less often?
Code of Federal Regulations, 2010 CFR
2010-07-01
... least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen chloride, or...) If your CISWI unit continues to meet the emission limitation for particulate matter, hydrogen... shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or opacity, you...
Suggesting a new framework for predictive performance assessment: Trait vs State dimensions.
NASA Astrophysics Data System (ADS)
Pattyn, Nathalie; Neyt, Xavier; Migeotte, Pierre-François; Morais, José; Soetens, Eric; Cluydts, Raymond; Meeusen, Romain; de Schutter, Guy; Nederhof, Esther; Kolinsky, Régine
IntroductionA major aim of performance investigation is to predict real-life performance, which is why both ESA (1) and NASA (2) have described the need to validly and reliably detect potential performance decrement as absolute requirements to manned long-duration missions. Whereas the predictive validity of such assessment has been extensively described for medium-term to long-term outcomes, as is the case for cognitive performance selection of student pilots for example, similar evidence is lacking regarding the immediate predictive value of cognitive testing, i.e., whether these results reflect real-life performance on an immediately subsequent task. Furthermore, whereas selection procedures are derived from population-based approaches, real-time monitoring of performance is often meant to be individual, which is an additional call for caution before concluding results from one setting to be applied to another. The MiniCog Rapid Assessment Battery (MRAB), which was termed by its authors "a blood pressure cuff for the mind" (3), aims at reflecting the functional status of a subject at any given moment. This battery was designed to provide a remote cognitive assessment of astronauts on a regular basis. We investigated its predictive value for real-life performance, together with a new approach to the assessment of cognitive performance in operational conditions, based on interference paradigms, the addition of emotionally loaded material and the concomitant measure of cardio-respiratory responses (4). MethodIn a first experiment, we investigated whether psychophysiological results would predict success of military student pilots (SPs; N=14) on a major evaluation flight right after the testing, and success in the rest of their flight training after a 6 months period. In a second experiment, we investigated whether extensive preliminary cognitive testing and individually tailored longitudinal monitoring of physical and cognitive performance could predict success of Special Forces trainees (N=7) during their training. ResultsThe first experiment showed no relationship whatsoever between cognitive performance on the very broad array of tests and immediately subsequent performance on the evaluation flight. However, physiological results showed a trend for students who passed the test to exhibit a larger physiological reactivity. Furthermore, the medium-term outcome of SPs in their flight training showed to be related to their test performance. Results of the second experiment (still in progress) will show whether, for an individual monitoring situation, there is a potential link between performance IQ and success on the training, and whether the longitudinal assessment of both cognitive performance, physical performance and physiological reactivity relates to immediately subsequent performance. DiscussionThese results suggest that a critical distinction could be made regarding predictive performance assessment, namely trait and state dimensions. Since one of the intended uses of operational test batteries is to provide an instantaneous measure of the cognitive status of the subject to allow the immediate execution of critical tasks, our results show this would be an inappropriate application so far. However, a dimension showing promising potential is the physiological reactivity. Whereas operational priorities clearly state the need for performance evaluation tools, their application cannot guide operational choices before sufficient validation allows justifying such decisions. References(1) HUMEX: Study on the Survivability and Adaptation of Humans to Long-duration Exploratory Missions (2000). European Space Agency. (2)BPCR: Bioastronautics Critical Path Roadmap (2004). National Aeronautics and Space Administration. (3) Shephard, J. M. and Kosslyn, S. M. (2005). The MiniCog rapid assessment battery: Developing a "blood pressure cuff for the mind". Avn Space Enl Medicine, 76, B192-B197. (4) Pattyn, N.; Migeotte, P.F.; Morais, J.; Soetens, E.; Cluydts, R. and Kolinsky, R. (2007). Crew performance monitoring: Putting some feeling into it. Proceedings of the 58th International Astronautical Congress, IAC-07-A1.1.04.
Brurok, Berit; Tjønna, Arnt Erik; Tørhaug, Tom; Askim, Torunn
2017-01-01
Background People with stroke have a low peak aerobic capacity and experience increased effort during performance of daily activities. The purpose of this study was to examine test-retest reliability of a portable ergospirometry system in people with stroke during performance of functional activities in a field-test. Secondary aims were to examine the proportion of oxygen consumed during the field-test in relation to the peak-test and to analyse the correlation between the oxygen uptake during the field-test and peak-test in order to support the validity of the field-test. Methods With simultaneous measurement of oxygen consumption, participants performed a standardized field-test consisting of five activities; walking over ground, stair walking, stepping over obstacles, walking slalom between cones and from a standing position lifting objects from one height to another. All activities were performed in self-selected speed. Prior to the field-test, a peak aerobic capacity test was performed. The field-test was repeated minimum 2 and maximum 14 days between the tests. ICC2,1 and Bland Altman tests (Limits of Agreement, LoA) were used to analyse test-retest reliability. Results In total 31 participants (39% women, mean (SD) age 54.5 (12.7) years and 21.1 (14.3) months’ post-stroke) were included. The ICC2,1 was ≥ 0.80 for absolute V̇O2, relative V̇O2, minute ventilation, CO2, respiratory exchange ratio, heart rate and Borgs rating of perceived exertion. ICC2,1 for total time to complete the field-test was 0.99. Mean difference in steady state V̇O2 during Test 1 and Test 2 was -0.40 (2.12) The LoAs were -3.75 and 4.51. Participants spent 60.7% of their V̇O2peak performing functional activities. Correlation between field-test and peak-test was 0.689, p = 0.001 for absolute and 0.733, p = 0.001 for relative V̇O2. Conclusions This study presents first evidence on reliability of oxygen uptake during performance of functional activities after stroke, showing very good test-retest reliability. The secondary analysis showed that the amount of energy spent during the field-test relative to the peak-test was high and the correlation between the two test was good, supporting the validity of this method. PMID:29065164
The effect of simulated weightlessness on performance and mood
NASA Technical Reports Server (NTRS)
Rosenberg, Bonnie
1988-01-01
The performance results of the bedrest study at Ames were not what were expected. The Air Combat Maneuvering performance test was tested to assure its reliability. However, the results from this study show a continued increase in performance. One would assume that scores would become constant if not decrease by the first days of bedrest because an inverted position would affect performance. It is also interesting to observe that while the subject's moods deteriorated, their performance improved. Although the performance results were surprising, the mood results were as expected.
Body Unloading Associated with Space Flight and Bed-rest Impacts Functional Performance
NASA Technical Reports Server (NTRS)
Bloomberg, J. J.; Ballard, K. L.; Batson, C. D.; Buxton, R. E.; Feiveson, A. H.; Kofman, I. S.; Lee, S. M. C.; Miller, C. A.; Mulavara, A. P.; Peters, B. T.;
2014-01-01
The goal of the Functional Task Test study is to determine the effects of space flight on functional tests that are representative of high priority exploration mission tasks and to identify the key underlying physiological factors that contribute to decrements in performance. Ultimately this information will be used to assess performance risks and inform the design of countermeasures for exploration class missions. We are currently conducting studies on both ISS crewmembers and on subjects experiencing 70 days of 6 degrees head-down bed-rest as an analog for space flight. Bed-rest provides the opportunity for us to investigate the role of prolonged axial body unloading in isolation from the other physiological effects produced by exposure to the microgravity environment of space flight. This allows us to parse out the contribution of the body unloading component on functional performance. In this on-going study both ISS crewmembers and bed-rest subjects were tested using an interdisciplinary protocol that evaluated functional performance and related physiological changes before and after 6 months in space and 70 days of 6? head-down bed-rest, respectively. Functional tests included ladder climbing, hatch opening, jump down, manual manipulation of objects and tool use, seat egress and obstacle avoidance, recovery from a fall, and object translation tasks. Crewmembers were tested three times before flight, and on 1, 6 and 30 days after landing. Bed-rest subjects were tested three times before bed-rest and immediately after getting up from bed-rest as well as 1, 6 and 12 days after reambulation. A comparison of bed-rest and space flight data showed a significant concordance in performance changes across all functional tests. Tasks requiring a greater demand for dynamic control of postural equilibrium (i.e. fall recovery, seat egress/obstacle avoidance during walking, object translation, jump down) showed the greatest decrement in performance. Functional tests with reduced requirements for postural stability (i.e. hatch opening, ladder climb, manual manipulation of objects and tool use) showed little reduction in performance. Bed-rest results indicate that body support unloading experienced during space flight plays a central role in postflight alteration of functional task performance. These data point to the importance of providing axial body loading as a central component of an inflight training system that will integrate cardiovascular, resistance and sensorimotor adaptability training modalities into a single interdisciplinary countermeasure system.
Short-term phonological memory in preschool children.
Rodrigues, Amalia; Befi-Lopes, Debora Maria
2013-01-01
The purpose of this study was to design a short-term memory test, to describe quantitative performance in typically language developing children and to verify the relationship between the non-words repetition and oral phonological measure. The participants included 136 typically language developing children aged from 3 years to 6 years and 11 months old in this study, who were evaluated. The test consisted of 40 non-words of one, two, three, and four syllables. The subjects' repetitions were transcribed and the number of right answers was calculated for each age range. The effect of age was observed in the test, as well as the effect of length, only for disyllabic non-words. The performance in the non-word repetition task showed correlation with the oral phonology measure. The test designed in this research was able to verify the short-term memory in typically language developing children and the results showed correlation between this memory and phonological performance.
Results of an On-Going Long Duration Ground Test of the DS1 Flight Spare Engine
NASA Technical Reports Server (NTRS)
Anderson, John R.; Goodfellow, Keith D.; Polk, James E.; Shotwell, Robert F.; Rawlin, Vincent K.; Sovey, James S.; Patterson, Michael J.
2000-01-01
Ground testing of the DS1 night spare thruster (FT2) is presently being conducted. To date, the thruster has accumulated over 4500 hours of operation. Comparison of FT2 with the performance of the engineering model thruster 2 (EMT2) during the 8.2 khr test shows a transient, lasting for about 3000 hours, during which the discharge chamber efficiency decreases for both thrusters. The flow rates are 2% lower for FT2 than for EMT2 and the discharge chamber performance is 4.5% lower for FT2 during the transient. Sensitivity data obtained during the test show that the lower flow rate accounts for about half of the observed difference. After the initial transients decay, the performance of both thrusters is comparable with the exception of the electron backstreaming margin--which is 6 V lower for FT2.
Energy efficient engine high-pressure turbine component rig performance test report
NASA Technical Reports Server (NTRS)
Leach, K. P.
1983-01-01
A rig test of the cooled high-pressure turbine component for the Energy Efficient Engine was successfully completed. The principal objective of this test was to substantiate the turbine design point performance as well as determine off-design performance with the interaction of the secondary flow system. The measured efficiency of the cooled turbine component was 88.5 percent, which surpassed the rig design goal of 86.5 percent. The secondary flow system in the turbine performed according to the design intent. Characterization studies showed that secondary flow system performance is insensitive to flow and pressure variations. Overall, this test has demonstrated that a highly-loaded, transonic, single-stage turbine can achieve a high level of operating efficiency.
Infrared suppressor effect on T63 turboshaft engine performance
NASA Technical Reports Server (NTRS)
Bailey, E. E.; Civinskas, K. C.; Walker, C. L.
1978-01-01
Tests were conducted to determine if there are performance penalties associated with the installation of infrared (IR) suppressors on the T63-A-700 turboshaft engine. The testing was done in a sea-level, static test cell. The same engine (A-E402808 B) was run with the standard OH-58 aircraft exhaust stacks and with the ejector-type IR suppressors in order to make a valid comparison. Repeatability of the test results for the two configurations was verified by rerunning the conditions over a period of days. Test results showed no measurable difference in performance between the standard exhaust stacks and the IR suppressors.
NASA Technical Reports Server (NTRS)
Mehta, Manish; Seaford, Mark; Kovarik, Brian; Dufrene, Aaron; Solly, Nathan
2014-01-01
ATA-002 Technical Team has successfully designed, developed, tested and assessed the SLS Pathfinder propulsion systems for the Main Base Heating Test Program. Major Outcomes of the Pathfinder Test Program: Reach 90% of full-scale chamber pressure Achieved all engine/motor design parameter requirements Reach steady plume flow behavior in less than 35 msec Steady chamber pressure for 60 to 100 msec during engine/motor operation Similar model engine/motor performance to full-scale SLS system Mitigated nozzle throat and combustor thermal erosion Test data shows good agreement with numerical prediction codes Next phase of the ATA-002 Test Program Design & development of the SLS OML for the Main Base Heating Test Tweak BSRM design to optimize performance Tweak CS-REM design to increase robustness MSFC Aerosciences and CUBRC have the capability to develop sub-scale propulsion systems to meet desired performance requirements for short-duration testing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dreier, J.; Huggenberger, M.; Aubert, C.
1996-08-01
The PANDA test facility at PSI in Switzerland is used to study the long-term Simplified Boiling Water Reactor (SBWR) Passive Containment Cooling System (PCCS) performance. The PANDA tests demonstrate performance on a larger scale than previous tests and examine the effects of any non-uniform spatial distributions of steam and non-condensables in the system. The PANDA facility has a 1:1 vertical scale, and 1:25 ``system`` scale (volume, power, etc.). Steady-state PCCS condenser performance tests and extensive facility characterization tests have been completed. Transient system behavior tests were conducted late in 1995; results from the first three transient tests (M3 series) aremore » reviewed. The first PANDA tests showed that the overall global behavior of the SBWR containment was globally repeatable and very favorable; the system exhibited great ``robustness.``« less
Design and Operation of a Calorimeter for Advanced Multilayer Insulation Testing
NASA Technical Reports Server (NTRS)
Chato, David J.; Johnson, Wesley L.; Van Dresar, Neil
2016-01-01
A calorimeter has been constructed to accurately measure insulation performance with a nominal 90K outer boundary and a 20K inner boundary. Unique features of this design include use of mechanical cryocoolers instead of cryogens and measurement of the heat load with a calibrated heat conduction rod. The calorimeter is operational and has completed its first test series. The initial test series was designed to look for differences in performance between a single layer of aluminum foil and a sheet of double aluminized Mylar (DAM). Although it has been speculated that the aluminum foil would perform better, since the aluminum coating on the Mylar might not be thick enough to stop the transmission of long wave length infrared radiation, our testing showed a higher heat load for the aluminum foil than the DAM. The aluminum foil showed a heat load of 132 mW at an 87 K outer temperature and 152 mW at a 107K outer temperature, whereas the DAM showed a heat load of 66 mW at an 88 K outer temperature and 81 mW at 108 K.
Design and Operation of a Calorimeter for Advanced Multilayer Insulation Testing
NASA Technical Reports Server (NTRS)
Chato, David; Johnson, Wesley; Dresar, Neil Van
2016-01-01
A calorimeter has been constructed to accurately measure insulation performance with a nominal 90K cold outer boundary and a 20K inner boundary. Unique features of this design include use of mechanical cryocoolers instead cryogens and measurement of the heat load with a calibrated rod to serve as a conduction path. The calorimeter is operational and has completed its first test series. The initial test series was designed to look for differences in performance between a single layer of aluminum foil and a sheet of double aluminized mylar (DAM). Although it has been speculated that the aluminum foil would perform better, since the mylar coating might not thick enough to stop the transmission of long wave length infrared radiation, our testing showed a higher heat load for the aluminum foil than the DAM. The aluminum foil showed a heat load of 132 mW at an 87 K outer temperature and 152 mW at a 107K outer temperature. Whereas the DAM showed a heat load of 66 mW at an 88 K outer temperature and 81 mW at 108 K.
Histogram equalization with Bayesian estimation for noise robust speech recognition.
Suh, Youngjoo; Kim, Hoirin
2018-02-01
The histogram equalization approach is an efficient feature normalization technique for noise robust automatic speech recognition. However, it suffers from performance degradation when some fundamental conditions are not satisfied in the test environment. To remedy these limitations of the original histogram equalization methods, class-based histogram equalization approach has been proposed. Although this approach showed substantial performance improvement under noise environments, it still suffers from performance degradation due to the overfitting problem when test data are insufficient. To address this issue, the proposed histogram equalization technique employs the Bayesian estimation method in the test cumulative distribution function estimation. It was reported in a previous study conducted on the Aurora-4 task that the proposed approach provided substantial performance gains in speech recognition systems based on the acoustic modeling of the Gaussian mixture model-hidden Markov model. In this work, the proposed approach was examined in speech recognition systems with deep neural network-hidden Markov model (DNN-HMM), the current mainstream speech recognition approach where it also showed meaningful performance improvement over the conventional maximum likelihood estimation-based method. The fusion of the proposed features with the mel-frequency cepstral coefficients provided additional performance gains in DNN-HMM systems, which otherwise suffer from performance degradation in the clean test condition.
Neden, Catherine A; Parkin, Claire; Blow, Carol; Siriwardena, Aloysius Niroshan
2018-05-08
The aim of this study was to assess whether the absolute standard of candidates sitting the MRCGP Applied Knowledge Test (AKT) between 2011 and 2016 had changed. It is a descriptive study comparing the performance on marker questions of a reference group of UK graduates taking the AKT for the first time between 2011 and 2016. Using aggregated examination data, the performance of individual 'marker' questions was compared using Pearson's chi-squared tests and trend-line analysis. Binary logistic regression was used to analyse changes in performance over the study period. Changes in performance of individual marker questions using Pearson's chi-squared test showed statistically significant differences in 32 of the 49 questions included in the study. Trend line analysis showed a positive trend in 29 questions and a negative trend in the remaining 23. The magnitude of change was small. Logistic regression did not demonstrate any evidence for a change in the performance of the question set over the study period. However, candidates were more likely to get items on administration wrong compared with clinical medicine or research. There was no evidence of a change in performance of the question set as a whole.
Validity of the Worth 4 Dot Test in Patients with Red-Green Color Vision Defect.
Bak, Eunoo; Yang, Hee Kyung; Hwang, Jeong-Min
2017-05-01
The Worth four dot test uses red and green glasses for binocular dissociation, and although it has been believed that patients with red-green color vision defects cannot accurately perform the Worth four dot test, this has not been validated. Therefore, the purpose of this study was to demonstrate the validity of the Worth four dot test in patients with congenital red-green color vision defects who have normal or abnormal binocular vision. A retrospective review of medical records was performed on 30 consecutive congenital red-green color vision defect patients who underwent the Worth four dot test. The type of color vision anomaly was determined by the Hardy Rand and Rittler (HRR) pseudoisochromatic plate test, Ishihara color test, anomaloscope, and/or the 100 hue test. All patients underwent a complete ophthalmologic examination. Binocular sensory status was evaluated with the Worth four dot test and Randot stereotest. The results were interpreted according to the presence of strabismus or amblyopia. Among the 30 patients, 24 had normal visual acuity without strabismus nor amblyopia and 6 patients had strabismus and/or amblyopia. The 24 patients without strabismus nor amblyopia all showed binocular fusional responses by seeing four dots of the Worth four dot test. Meanwhile, the six patients with strabismus or amblyopia showed various results of fusion, suppression, and diplopia. Congenital red-green color vision defect patients of different types and variable degree of binocularity could successfully perform the Worth four dot test. They showed reliable results that were in accordance with their estimated binocular sensory status.
Analysis of Eighth Graders' Performance On Standardized Mathematics Tests.
ERIC Educational Resources Information Center
Meyinsse, Joseph; Tashakkori, Abbas
The main objective of this study was to show whether eighth graders' performance on standardized mathematics tests could be predicted from a variety of variables. These predictors included the students' race/ethnicity, gender, attitudes toward mathematics, students' time spent on homework, whether parents helped with homework assignments,…
Music and Spatial Task Performance: A Causal Relationship.
ERIC Educational Resources Information Center
Rauscher, Frances H.; And Others
This research paper reports on testing the hypothesis that music and spatial task performance are causally related. Two complementary studies are presented that replicate and explore previous findings. One study of college students showed that listening to a Mozart sonata induces subsequent short-term spatial reasoning facilitation and tested the…
NASA Astrophysics Data System (ADS)
Jolly, Anju B.
The purpose of this study was to analyze the relationship of concept mapping to science problem solving in sixth grade elementary school children. The study proposes to determine whether the students' ability to perform higher cognitive processes was a predictor of students' performance in solving problems in science and whether gender and socioeconomic status are related to performance in solving problems. Two groups participated in the study. Both groups were given a pre-test of higher cognitive ability--the Ross Test of Higher Cognitive Ability. One group received instruction on a science unit of study in concept mapping format and the other group received instruction in traditional format. The instruction lasted approximately 4 weeks. Both groups were given a problem-solving post-test. A comparison of post-test means was done using Analysis of Covariance (ANCOVA) as the statistical procedure with scores on the test of higher cognitive ability as the covariate. Also, Multiple Regression was performed to analyze the influence of participants' gender and socioeconomic status on their performance in solving problems. Results from the analysis of covariance showed that the group receiving instruction in the concept mapping format performed significantly better than the group receiving instruction in traditional format. Also the Ross Test of Higher Cognitive Processes emerged to be a predictor of performance on problem solving. There was no significant difference in the analysis of the performance of males and females. No pattern emerged regarding the influence of socioeconomic status on problem solving performance. In conclusion, the study showed that concept mapping improved problem solving in the classroom, and that gender and socioeconomic status are not predictors of student success in problem solving.
NASA Technical Reports Server (NTRS)
Stokes, R. L.
1979-01-01
Electrical characterization tests were performed on two different manufactured types of integrated circuits. The devices were subjected to functional and AC and DC parametric tests at ambient temperatures of -55 C, -20 C, 25 C, 85 C, and 125 C. The data were analyzed and tabulated to show the effect of operating conditions on performance and to indicate parameter deviations among devices in each group. Accuracy was given precedence over test time efficiency where practical, and tests were designed to measure worst case performance.
NASA Technical Reports Server (NTRS)
Roman, Monsi C.; Mittelman, Marc W.
2010-01-01
This slide presentation summarizes the studies performed to assess the bulk phase microbial community during the Space Station Water Recover Tests (WRT) from 1990-1998. These tests show that it is possible to recycle water from different sources including urine, and produce water that can exceed the quality of municpally produced tap water.
ERIC Educational Resources Information Center
Starr, Joshua P.; Spellings, Margaret
2014-01-01
More than 40 states plan to assess student performance with new tests tied to the Common Core State Standards. In summer 2013, results from Common Core-aligned tests in New York showed a steep decline in outcomes. Common Core advocates hailed the scores as an honest accounting of school and student performance, while others worried that they…
Development of self and peer performance assessment on iodometric titration experiment
NASA Astrophysics Data System (ADS)
Nahadi; Siswaningsih, W.; Kusumaningtyas, H.
2018-05-01
This study aims to describe the process in developing of reliable and valid assessment to measure students’ performance on iodometric titration and the effect of the self and peer assessment on students’ performance. The self and peer-instrument provides valuable feedback for the student performance improvement. The developed assessment contains rubric and task for facilitating self and peer assessment. The participants are 24 students at the second-grade student in certain vocational high school in Bandung. The participants divided into two groups. The first 12 students involved in the validity test of the developed assessment, while the remain 12 students participated for the reliability test. The content validity was evaluated based on the judgment experts. Test result of content validity based on judgment expert show that the developed performance assessment instrument categorized as valid on each task with the realibity classified as very good. Analysis of the impact of the self and peer assessment implementation showed that the peer instrument supported the self assessment.
Data on the no-load performance analysis of a tomato postharvest storage system.
Ayomide, Orhewere B; Ajayi, Oluseyi O; Banjo, Solomon O; Ajayi, Adesola A
2017-08-01
In this present investigation, an original and detailed empirical data on the transfer of heat in a tomato postharvest storage system was presented. No-load tests were performed for a period of 96 h. The heat distribution at different locations, namely the top, middle and bottom of the system was acquired, at a time interval of 30 min for the test period. The humidity inside the system was taken into consideration. Thus, No-load tests with or without introduction of humidity were carried out and data showing the effect of a rise in humidity level, on temperature distribution were acquired. The temperatures at the external mechanical cooling components were acquired and could be used for showing the performance analysis of the storage system.
Judgments of Learning are Influenced by Multiple Cues In Addition to Memory for Past Test Accuracy.
Hertzog, Christopher; Hines, Jarrod C; Touron, Dayna R
When people try to learn new information (e.g., in a school setting), they often have multiple opportunities to study the material. One of the most important things to know is whether people adjust their study behavior on the basis of past success so as to increase their overall level of learning (for example, by emphasizing information they have not yet learned). Monitoring their learning is a key part of being able to make those kinds of adjustments. We used a recognition memory task to replicate prior research showing that memory for past test outcomes influences later monitoring, as measured by judgments of learning (JOLs; confidence that the material has been learned), but also to show that subjective confidence in whether the test answer and the amount of time taken to restudy the items also have independent effects on JOLs. We also show that there are individual differences in the effects of test accuracy and test confidence on JOLs, showing that some but not all people use past test experiences to guide monitoring of their new learning. Monitoring learning is therefore a complex process of considering multiple cues, and some people attend to those cues more effectively than others. Improving the quality of monitoring performance and learning could lead to better study behaviors and better learning. An individual's memory of past test performance (MPT) is often cited as the primary cue for judgments of learning (JOLs) following test experience during multi-trial learning tasks (Finn & Metcalfe, 2007; 2008). We used an associative recognition task to evaluate MPT-related phenomena, because performance monitoring, as measured by recognition test confidence judgments (CJs), is fallible and varies in accuracy across persons. The current study used multilevel regression models to show the simultaneous and independent influences of multiple cues on Trial 2 JOLs, in addition to performance accuracy (the typical measure of MPT in cued-recall experiments). These cues include recognition CJs, perceived recognition fluency, and Trial 2 study time allocation (an index of reprocessing fluency). Our results expand the scope of MPT-related phenomena in recognition memory testing to show independent effects of recognition test accuracy and CJs on second-trial JOLs, while also demonstrating individual differences in the effects of these cues on JOLs (as manifested in significant random effects for those regression effects in the model). The effect of study time on second-trial JOLs controlling on other variables, including Trial 1 recognition memory accuracy, also demonstrates that second-trial encoding behavior influence JOLs in addition to MPT.
Rover Low Gain Antenna Qualification for Deep Space Thermal Environments
NASA Technical Reports Server (NTRS)
Ramesham, Rajeshuni; Amaro, Luis R.; Brown, Paula R.; Usiskin, Robert; Prater, Jack L.
2013-01-01
A method to qualify the Rover Low Gain Antenna (RLGA) for use during the Mars Science Laboratory (MSL) mission has been devised. The RLGA antenna must survive all ground operations, plus the nominal 670 Martian sol mission that includes the summer and winter seasons of the Mars thermal environment. This qualification effort was performed to verify that the RLGA design, its bonding, and packaging processes are adequate. The qualification test was designed to demonstrate a survival life of three times more than all expected ground testing, plus a nominal 670 Martian sol missions. Baseline RF tests and a visual inspection were performed on the RLGA hardware before the start of the qualification test. Functional intermittent RF tests were performed during thermal chamber breaks over the course of the complete qualification test. For the return loss measurements, the RLGA antenna was moved to a test area. A vector network analyzer was calibrated over the operational frequency range of the antenna. For the RLGA, a simple return loss measurement was performed. A total of 2,010 (3 670 or 3 times mission thermal cycles) thermal cycles was performed. Visual inspection of the RLGA hardware did not show any anomalies due to the thermal cycling. The return loss measurement results of the RLGA antenna after the PQV (Package Qualification and Verification) test did not show any anomalies. The antenna pattern data taken before and after the PQV test at the uplink and downlink frequencies were unchanged. Therefore, the developed design of RLGA is qualified for a long-duration MSL mission.
Acoustic tests of duct-burning turbofan jet noise simulation
NASA Technical Reports Server (NTRS)
Knott, P. R.; Stringas, E. J.; Brausch, J. F.; Staid, P. S.; Heck, P. H.; Latham, D.
1978-01-01
The results of a static acoustic and aerodynamic performance, model-scale test program on coannular unsuppressed and multielement fan suppressed nozzle configurations are summarized. The results of the static acoustic tests show a very beneficial interaction effect. When the measured noise levels were compared with the predicted noise levels of two independent but equivalent conical nozzle flow streams, noise reductions for the unsuppressed coannular nozzles were of the order of 10 PNdB; high levels of suppression (8 PNdB) were still maintained even when only a small amount of core stream flow was used. The multielement fan suppressed coannular nozzle tests showed 15 PNdB noise reductions and up to 18 PNdB noise reductions when a treated ejector was added. The static aerodynamic performance tests showed that the unsuppressed coannular plug nozzles obtained gross thrust coefficients of 0.972, with 1.2 to 1.7 percent lower levels for the multielement fan-suppressed coannular flow nozzles. For the first time anywhere, laser velocimeter velocity profile measurements were made on these types of nozzle configurations and with supersonic heated flow conditions. Measurements showed that a very rapid decay in the mean velocity occurs for the nozzle tested.
ERIC Educational Resources Information Center
California Postsecondary Education Commission, 2007
2007-01-01
As part of its work in developing a performance accountability framework for higher education, the Commission conducted an analysis of student performance on standardized tests at the high school and middle school levels. National test results show that California is behind most other states in giving its students a high school education of the…
ERIC Educational Resources Information Center
Krinsky-McHale, Sharon J.; Devenny, Darlynne A.; Kittler, Phyllis; Silverman, Wayne
2008-01-01
Adults with Down syndrome and early stage Alzheimer's disease showed decline in their ability to selectively attend to stimuli in a multitrial cancellation task. They also showed variability in their performance over the test trials, whereas healthy participants showed stability. These changes in performance were observed approximately 2 years…
Noël, Audrey; Berhin, Catherine; Hoebeke, Martin; Bouchahrouf, Warda; Yunus, Sami; Bogaerts, Pierre; Glupczynski, Youri
2016-01-01
ABSTRACT Four screening assays aimed for rapid detection of carbapenemase production from Gram-negative bacterial isolates, i.e., the Neo-Rapid Carb kit (Rosco Diagnostica A/S), the Rapidec Carba NP test (bioMérieux SA), the β Carba test (Bio-Rad Laboratories N.V.), and a homemade electrochemical assay (BYG Carba test) were evaluated against a panel comprising 328 clinical isolates (Enterobacteriaceae [n = 198] and nonfermentative Gram-negative bacilli [n = 130]) with previously characterized resistance mechanisms to carbapenems. Among Enterobacteriaceae isolates, the BYG Carba test and the β Carba test showed excellent sensitivities (respectively, 100% and 97.3%) and specificities (respectively, 98.9% and 97.7%). The two other assays yielded poorer performances with sensitivity and specificity of 91.9% and 83.9% for the Rapidec Carba NP test and of 89.2% and 89.7% for the Neo-Rapid Carb kit, respectively. Among Pseudomonas spp., sensitivities and specificities ranged, respectively, from 87.3% to 92.7% and from 88.2% to 94.1%. Finally, all tests performed poorly against Acinetobacter spp., with sensitivities and specificities, respectively, ranging from 27.3% to 75.8% and from 75 to 100%. Among commercially available assays, the β Carba test appeared to be the most convenient for routine use and showed the best overall performances, especially against OXA-48-like producers. The excellent performance of the BYG Carba test against Enterobacteriaceae was confirmed (100% sensitivity and 98.9% specificity). PMID:27927915
NASA Technical Reports Server (NTRS)
Marshburn, J. P.
1973-01-01
Techniques associated with thermal-vacuum and bench testing, along with flight testing of the OAO-C spacecraft heat pipes are outlined, to show that the processes used in heat transfer design and testing are adequate for good performance evaluations.
NASA Technical Reports Server (NTRS)
Harkness, J. D.
1977-01-01
Performance data concerning sealed nickel-cadmium cells operating under a synchronous orbit regime are presented. A space satellite maintaining a position over a fixed point on earth as the earth rotates on its axis and revolves about the sun was simulated. Results include: (1) exposure to synchronous orbit testing at a temperature of 40 C yields less than 6 years of life; (2) performance at -20 C presents a low capacity problem; (3) the capacity check, performed at the middle of each show period, provides a temporary red reconditioning effect on the cells in that the end-of-discharge voltages are higher, for approximately 7 to 10 days, following the capacity check than they were 7 to 10 days prior to the capacity check; (4) all the test packs at -20 C and 40 C have either failed or were discontinued because of low capacity; and (5) test packs at temperatures of 0 C and 10 C have delivered the best capacity during life and packs tested at 20 C showed better life capability than packs tested at -20 C and 40 C.
A comparison of visual inspection time measures in children with cerebral palsy.
Kaufman, Jacqueline N; Donders, Jacobus; Warschausky, Seth
2014-05-01
This study examined the performance of children with and without cerebral palsy on two inspection time (IT) tests, as accessible nonspeeded response measures of cognitive processing speed. Participants, ages 8 to 16, included 66 children with congenital CP and 119 typically developing peers. Measures were two visual IT tasks with identical target stimuli but differential response strategies either via a traditional dual-key method or with an assistive technology pressure switch interface and response option scanning. The CP group had slower IT than the control group independent of test version. Log transformations were used to address skew, and transformed mean intraclass correlations showed moderate agreement between test versions for both participant groups. Bland-Altman plots showed that at higher mean IT thresholds, greater discrepancies between test version scores were observed. Findings support the feasibility of developing tests that reduce speeded motor response demands. Future test development should incorporate increased gradations of difficulty at the extremes of neuropsychological functioning to more accurately assess the performance of individuals whose conditions are associated with atypical performance levels. (c) 2014 APA, all rights reserved.
Clemensson, Erik Karl Håkan; Clemensson, Laura Emily; Riess, Olaf; Nguyen, Huu Phuc
2017-01-01
The BACHD rat is a recently developed transgenic animal model of Huntington disease, a progressive neurodegenerative disorder characterized by extensive loss of striatal neurons. Cognitive impairments are common among patients, and characterization of similar deficits in animal models of the disease is therefore of interest. The present study assessed the BACHD rats' performance in the delayed alternation and the delayed non-matching to position test, two Skinner box-based tests of short-term memory function. The transgenic rats showed impaired performance in both tests, indicating general problems with handling basic aspects of the tests, while short-term memory appeared to be intact. Similar phenotypes have been found in rats with fronto-striatal lesions, suggesting that Huntington disease-related neuropathology might be present in the BACHD rats. Further analyses indicated that the performance deficit in the delayed alternation test might be due to impaired inhibitory control, which has also been implicated in Huntington disease patients. The study ultimately suggests that the BACHD rats might suffer from neuropathology and cognitive impairments reminiscent of those of Huntington disease patients.
Tsoi, Kelvin K F; Chan, Joyce Y C; Hirai, Hoyee W; Wong, Adrian; Mok, Vincent C T; Lam, Linda C W; Kwok, Timothy C Y; Wong, Samuel Y S
2017-09-01
Mild cognitive impairment (MCI) is a prevalent symptom associated with the increased risk of dementia. There are many cognitive tests available for detection of MCI, and investigation of the diagnostic performance of the tests is deemed necessary. This study aims to evaluate the diagnostic performance of different cognitive tests used for MCI detection. A list of cognitive tests was identified in previous reviews and from online search engines. Literature searches were performed on each of the cognitive tests in MEDLINE, Embase, and PsycINFO from the earliest available dates of individual databases to December 31, 2016. Google Scholar was used as a supplementary search tool. Studies that were used to assess the diagnostic performance of the cognitive tests were extracted with inclusion and exclusion criteria. Each test's performance was compared with the standard diagnostic criteria. Bivariate random effects models were used to summarize the test performance as a point estimate for sensitivity and specificity, and presented in a summary receiver operating characteristic curve. Reporting quality and risk of bias were evaluated. A total of 108 studies with 23,546 participants were selected to evaluate 9 cognitive tests for MCI detection. Most of the studies used the Mini-Mental State Examination (MMSE) (n = 58) and the Montreal Cognitive Assessment (MoCA) (n = 35). The combined diagnostic performance of the MMSE in MCI detection was 0.71 sensitivity [95% confidence interval (CI): 0.66-0.75] and 0.74 specificity (95% CI: 0.70-0.78), and of the MoCA in MCI detection was 0.83 sensitivity (95% CI: 0.80-0.86) and 0.75 specificity (95% CI: 0.69-0.80). Among the 9 cognitive tests, recall tests showed the best diagnostic performance with 0.89 sensitivity (95% CI: 0.86-0.92) and 0.84 specificity (95% CI, 0.79-0.89). In subgroup analyses, long- or short-delay recall tests have shown better performance than immediate recall tests. Recall tests were shown to be the most effective test in MCI detection, especially for the population with symptoms of memory deterioration. They can be potentially used as the triage screening test for MCI in primary care setting. But when a patient shows cognitive impairments beyond memory deterioration, a more comprehensive test such as the MoCA should be used. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.
Kosack, Cara S; Page, Anne-Laure; Beelaert, Greet; Benson, Tumwesigye; Savane, Aboubacar; Ng’ang’a, Anne; Andre, Bita; Zahinda, Jean-Paul BN; Shanks, Leslie; Fransen, Katrien
2017-01-01
Abstract Introduction: Although individual HIV rapid diagnostic tests (RDTs) show good performance in evaluations conducted by WHO, reports from several African countries highlight potentially significant performance issues. Despite widespread use of RDTs for HIV diagnosis in resource-constrained settings, there has been no systematic, head-to-head evaluation of their accuracy with specimens from diverse settings across sub-Saharan Africa. We conducted a standardized, centralized evaluation of eight HIV RDTs and two simple confirmatory assays at a WHO collaborating centre for evaluation of HIV diagnostics using specimens from six sites in five sub-Saharan African countries. Methods: Specimens were transported to the Institute of Tropical Medicine (ITM), Antwerp, Belgium for testing. The tests were evaluated by comparing their results to a state-of-the-art reference algorithm to estimate sensitivity, specificity and predictive values. Results: 2785 samples collected from August 2011 to January 2015 were tested at ITM. All RDTs showed very high sensitivity, from 98.8% for First Response HIV Card Test 1–2.0 to 100% for Determine HIV 1/2, Genie Fast, SD Bioline HIV 1/2 3.0 and INSTI HIV-1/HIV-2 Antibody Test kit. Specificity ranged from 90.4% for First Response to 99.7% for HIV 1/2 STAT-PAK with wide variation based on the geographical origin of specimens. Multivariate analysis showed several factors were associated with false-positive results, including gender, provider-initiated testing and the geographical origin of specimens. For simple confirmatory assays, the total sensitivity and specificity was 100% and 98.8% for ImmunoComb II HIV 12 CombFirm (ImmunoComb) and 99.7% and 98.4% for Geenius HIV 1/2 with indeterminate rates of 8.9% and 9.4%. Conclusions: In this first systematic head-to-head evaluation of the most widely used RDTs, individual RDTs performed more poorly than in the WHO evaluations: only one test met the recommended thresholds for RDTs of ≥99% sensitivity and ≥98% specificity. By performing all tests in a centralized setting, we show that these differences in performance cannot be attributed to study procedure, end-user variation, storage conditions, or other methodological factors. These results highlight the existence of geographical and population differences in individual HIV RDT performance and underscore the challenges of designing locally validated algorithms that meet the latest WHO-recommended thresholds. PMID:28364560
Rise time and response measurements on a LiSOCl2 cell
NASA Technical Reports Server (NTRS)
Bastien, Caroline; Lecomte, Eric J.
1992-01-01
Dynamic impedance tests were performed on a 180 Ah LiSOCl2 cell in the frame of a short term work contract awarded by Aerospatiale as part of the Hermes Space Plane development work. These tests consisted of rise time and response measurements. The rise time test was performed to show the ability to deliver 4 KW, in the nominal voltage range (75-115 V), within less than 100 microseconds, and after a period at rest of 13 days. The response measurements test consisted of step response and frequency response tests. The frequency response test was performed to characterize the response of the LiSOCl2 cell to a positive or negative load step of 10 A starting from various currents. The test was performed for various depths of discharge and various temperatures. The test results were used to build a mathematical, electrical model of the LiSOCl2 cell which are also presented. The test description, test results, electrical modelization description, and conclusions are presented.
Moreno-García, Inmaculada; Delgado-Pardo, Gracia; Roldán-Blasco, Carmen
2015-03-03
This study assesses attention and response control through visual and auditory stimuli in a primary care pediatric sample. The sample consisted of 191 participants aged between 7 and 13 years old. It was divided into 2 groups: (a) 90 children with ADHD, according to diagnostic (DSM-IV-TR) (APA, 2002) and clinical (ADHD Rating Scale-IV) (DuPaul, Power, Anastopoulos, & Reid, 1998) criteria, and (b) 101 children without a history of ADHD. The aims were: (a) to determine and compare the performance of both groups in attention and response control, (b) to identify attention and response control deficits in the ADHD group. Assessments were carried out using the Integrated Visual and Auditory Continuous Performance Test (IVA/CPT, Sandford & Turner, 2002). Results showed that the ADHD group had visual and auditory attention deficits, F(3, 170) = 14.38; p < .01, deficits in fine motor regulation (Welch´s t-test = 44.768; p < .001) and sensory/motor activity (Welch'st-test = 95.683, p < .001; Welch's t-test = 79.537, p < .001). Both groups exhibited a similar performance in response control, F(3, 170) = .93, p = .43.Children with ADHD showed inattention, mental processing speed deficits, and loss of concentration with visual stimuli. Both groups yielded a better performance in attention with auditory stimuli.
Boy, Nikolas; Heringer, Jana; Haege, Gisela; Glahn, Esther M; Hoffmann, Georg F; Garbade, Sven F; Kölker, Stefan; Burgard, Peter
2015-12-22
Glutaric aciduria type I (GA-I) is an inherited metabolic disease due to deficiency of glutaryl-CoA dehydrogenase (GCDH). Cognitive functions are generally thought to be spared, but have not yet been studied in detail. Thirty patients detected by newborn screening (n = 13), high-risk screening (n = 3) or targeted metabolic testing (n = 14) were studied for simple reaction time (SRT), continuous performance (CP), visual working memory (VWM), visual-motor coordination (Tracking) and visual search (VS). Dystonia (n = 13 patients) was categorized using the Barry-Albright-Dystonia Scale (BADS). Patients were compared with 196 healthy controls. Developmental functions of cognitive performances were analysed using a negative exponential function model. BADS scores correlated with speed tests but not with tests measuring stability or higher cognitive functions without time constraints. Developmental functions of GA-I patients significantly differed from controls for SRT and VS but not for VWM and showed obvious trends for CP and Tracking. Dystonic patients were slower in SRT and CP but reached their asymptote of performance similar to asymptomatic patients and controls in all tests. Asymptomatic patients did not differ from controls, except showing significantly better results in Tracking and a trend for slower reactions in visual search. Data across all age groups of patients and controls fitted well to a model of negative exponential development. Dystonic patients predominantly showed motor speed impairment, whereas performance improved with higher cognitive load. Patients without motor symptoms did not differ from controls. Developmental functions of cognitive performances were similar in patients and controls. Performance in tests with higher cognitive demand might be preserved in GA-I, even in patients with striatal degeneration.
Is there any difference in pelvic floor muscles performance between continent and incontinent women?
Burti, Juliana Schulze; Hacad, Claudia R; Zambon, João Paulo; Polessi, Emily Assis; Almeida, Fernando G
2015-08-01
To compare pelvic floor muscles (PFMs) performance in women with and without stress urinary incontinence (SUI) during endurance test. It is a prospective case-control clinical trial. After determining PFM maximal voluntary contraction (MVC) by electromyography (EMG), women underwent endurance test, which consisted of consecutively PFM 1-sec fast contractions reaching MVC amplitude followed by 1-sec rest. Training time guided by Borg perceived exertion scale was noted. Heart rate (HR) behavior and EMG variables were assessed before and after training making a physiological analysis in both groups. A total of 56 women, mean age 52.19 years old, were evaluated (26 continent and 30 incontinent women). The time that SUI and continent women took to reach fatigue (Borg 10) was 9.1 ± 4.7 and 14.19 ± 8.32 min, respectively (P = 0.006). Confirming that all women performed similar effort during the test, analysis of variance with repeated measures showed that during the endurance test both groups presented similar increase in HR, showing detectable and significant increase from resting time to Borg 10 (P < 0.001). Besides, there was similar behavior in EMG for continent and SUI women, with a decrease from the baseline resting amplitude (P = 0.003 for SUI women and P = 0.006 for continent women). Women with SUI showed worse performance during an endurance test than continent women. It suggests that women have different capacity to perform PFM training. An initial evaluation based on PFM performance would help to define the best individualized PFM training. © 2014 Wiley Periodicals, Inc.
Dantas, Jose Luiz; Pereira, Gleber; Nakamura, Fabio Yuzo
2015-09-01
The five-kilometer time trial (TT5km) has been used to assess aerobic endurance performance without further investigation of its validity. This study aimed to perform a preliminary validation of the TT5km to rank well-trained cyclists based on aerobic endurance fitness and assess changes of the aerobic endurance performance. After the incremental test, 20 cyclists (age = 31.3 ± 7.9 years; body mass index = 22.7 ± 1.5 kg/m(2); maximal aerobic power = 360.5 ± 49.5 W) performed the TT5km twice, collecting performance (time to complete, absolute and relative power output, average speed) and physiological responses (heart rate and electromyography activity). The validation criteria were pacing strategy, absolute and relative reliability, validity, and sensitivity. Sensitivity index was obtained from the ratio between the smallest worthwhile change and typical error. The TT5km showed high absolute (coefficient of variation < 3%) and relative (intraclass coefficient correlation > 0.95) reliability of performance variables, whereas it presented low reliability of physiological responses. The TT5km performance variables were highly correlated with the aerobic endurance indices obtained from incremental test (r > 0.70). These variables showed adequate sensitivity index (> 1). TT5km is a valid test to rank the aerobic endurance fitness of well-trained cyclists and to differentiate changes on aerobic endurance performance. Coaches can detect performance changes through either absolute (± 17.7 W) or relative power output (± 0.3 W.kg(-1)), the time to complete the test (± 13.4 s) and the average speed (± 1.0 km.h(-1)). Furthermore, TT5km performance can also be used to rank the athletes according to their aerobic endurance fitness.
Abram, Katrin; Bohne, Silvia; Bublak, Peter; Karvouniari, Panagiota; Klingner, Carsten M; Witte, Otto W; Guntinas-Lichius, Orlando; Axer, Hubertus
2016-01-01
Postural instability in patients with normal pressure hydrocephalus (NPH) is a most crucial symptom leading to falls with secondary complications. The aim of the current study was to evaluate the therapeutic effect of spinal tap on postural stability in these patients. Seventeen patients with clinical symptoms of NPH were examined using gait scale, computerized dynamic posturography (CDP), and neuropsychological assessment. Examinations were done before and after spinal tap test. The gait score showed a significant improvement 24 h after spinal tap test in all subtests and in the sum score (p < 0.003), while neuropsychological assessment did not reveal significant differences 72 h after spinal tap test. CDP showed significant improvements after spinal tap test in the Sensory Organization Tests 2 (p = 0.017), 4 (p = 0.001), and 5 (p = 0.009) and the composite score (p = 0.01). Patients showed best performance in somatosensory and worst performance in vestibular dominated tests. Vestibular dominated tests did not improve significantly after spinal tap test, while somatosensory and visual dominated tests did. Postural stability in NPH is predominantly affected by deficient vestibular functions, which did not improve after spinal tap test. Conditions which improved best were mainly independent from visual control and are based on proprioceptive functions.
Schønning, Kristian; Johansen, Kim; Nielsen, Lone Gilmor; Weis, Nina; Westh, Henrik
2018-07-01
Quantification of HBV DNA is used for initiating and monitoring antiviral treatment. Analytical test performance consequently impacts treatment decisions. To compare the analytical performance of the Aptima HBV Quant Assay (Aptima) and the COBAS Ampliprep/COBAS TaqMan HBV Test v2.0 (CAPCTMv2) for the quantification of HBV DNA in plasma samples. The performance of the two tests was compared on 129 prospective plasma samples, and on 63 archived plasma samples of which 53 were genotyped. Linearity of the two assays was assessed on dilutions series of three clinical samples (Genotype B, C, and D). Bland-Altman analysis of 120 clinical samples, which quantified in both tests, showed an average quantification bias (Aptima - CAPCTMv2) of -0.19 Log IU/mL (SD: 0.33 Log IU/mL). A single sample quantified more than three standard deviations higher in Aptima than in CAPCTMv2. Only minor differences were observed between genotype A (N = 4; average difference -0.01 Log IU/mL), B (N = 8; -0.13 Log IU/mL), C (N = 8; -0.31 Log IU/mL), D (N = 25; -0.22 Log IU/mL), and E (N = 7; -0.03 Log IU/mL). Deming regression showed that the two tests were excellently correlated (slope of the regression line 1.03; 95% CI: 0.998-1.068). Linearity of the tests was evaluated on dilution series and showed an excellent correlation of the two tests. Both tests were precise with %CV less than 3% for HBV DNA ≥3 Log IU/mL. The Aptima and CAPCTMv2 tests are highly correlated, and both tests are useful for monitoring patients chronically infected with HBV. Copyright © 2018 Elsevier B.V. All rights reserved.
Tests of a sputtered MoS2 lubricant film in various environments
NASA Technical Reports Server (NTRS)
Vest, C. E.
1976-01-01
This paper discusses conditions and results of several tests of a DC sputtered MoS2 dry lubricant film. The test components were miniature precision ball bearings and rings and blocks; the surrounding atmospheres were laboratory air, pure helium, vacuum to 10 to the -8th power torr, and a perfluoroalkylpolyether oil. The results showed that the lubricant would perform satisfactorily under lightly loaded (450 gm) ball bearings in vacuum and would not perform well under a 66-kg load in air, a 132-kg load in helium, or a 330-kg load under oil. These tests and others show that the sputtered MoS2 film has some desirable features for space applications as well as some definite limitations.
Short-term performance deterioration in JT9D-7A(SP) engine 695743
NASA Technical Reports Server (NTRS)
Bouchard, R. J.; Beyerly, W. R.; Sallee, G. P.
1978-01-01
The level of performance deterioration that occurred during early service was studied and also the contribution of each engine module to the overall level of engine performance deterioration. To assist in the distribution of the performance losses to the module level, testing with expanded experimental instrumentation was accomplished to permit direct measurement of module performance. An analytical teardown of the engine was accomplished to permit assignment of module performance losses to individual mechanical damage mechanisms including blade and seal wear, roughness, and thermal distortion of turbine parts. The results of the testing show that the engine deteriorated 1.5 percent in thrust specific fuel consumption from its performance when new. Initial testing, which included water washing, showed that 0.2 percent in performance deterioration was due to surface contamination (dirt) and 0.1 percent was due to drift of the engine vane control system, leaving 1.2 percent in basic TSFC deterioration. This 1.2 percent TSFC loss was distributed among the engine modules with 0.6 percent caused by clearance changes, 0.4 percent loss due to thermal distortion, and 0.2 percent loss due to increased roughness of the fan and low-pressure compressor airfoils.
Anthropometric and performance measures to study talent detection in youth volleyball.
Melchiorri, Giovanni; Viero, Valerio; Triossi, Tamara; Annino, Giuseppe; Padua, Elvira; Tancredi, Virginia
2017-12-01
The aim of this work was to study anthropometric and performance measurements in 60 young male volleyball players (YV) and 60 youth not active in the sport (YNA) to assess which of these would be more useful to study the characteristics of potential performers. Eight measures to assess anthropometric characteristics, six performance measures and two tests for joint mobility were used. Also relative age and level of maturation were assessed. The anthropometric variables, relative age and level of maturation measured did not show statistically significant differences between groups. The YV and YNA groups showed differences in the performance measures. YV group was characterized by a better performance of the ability to repeat short sprints, of the upper limbs, abdominal muscles and lower limbs, with a medium effect size (Shuttle Running Test: 0.6; Push-Up: 0.5; Sit-Up: 0.4; counter movement jump: 0.4). These performance variables were very sensitive and specific: the SRT measurement had the best positive likelihood ratio that indicates the utility of the test in identifying type of players (YV and YNA). In talent detection in youth volleyball, in the 11-13 age range, performance variables should be preferred to anthropometric ones.
Ren, Xuezhu; Schweizer, Karl; Wang, Tengfei; Xu, Fen
2015-01-01
The present study provides a new account of how fluid intelligence influences academic performance. In this account a complex learning component of fluid intelligence tests is proposed to play a major role in predicting academic performance. A sample of 2, 277 secondary school students completed two reasoning tests that were assumed to represent fluid intelligence and standardized math and verbal tests assessing academic performance. The fluid intelligence data were decomposed into a learning component that was associated with the position effect of intelligence items and a constant component that was independent of the position effect. Results showed that the learning component contributed significantly more to the prediction of math and verbal performance than the constant component. The link from the learning component to math performance was especially strong. These results indicated that fluid intelligence, which has so far been considered as homogeneous, could be decomposed in such a way that the resulting components showed different properties and contributed differently to the prediction of academic performance. Furthermore, the results were in line with the expectation that learning was a predictor of performance in school.
Ren, Xuezhu; Schweizer, Karl; Wang, Tengfei; Xu, Fen
2015-01-01
The present study provides a new account of how fluid intelligence influences academic performance. In this account a complex learning component of fluid intelligence tests is proposed to play a major role in predicting academic performance. A sample of 2, 277 secondary school students completed two reasoning tests that were assumed to represent fluid intelligence and standardized math and verbal tests assessing academic performance. The fluid intelligence data were decomposed into a learning component that was associated with the position effect of intelligence items and a constant component that was independent of the position effect. Results showed that the learning component contributed significantly more to the prediction of math and verbal performance than the constant component. The link from the learning component to math performance was especially strong. These results indicated that fluid intelligence, which has so far been considered as homogeneous, could be decomposed in such a way that the resulting components showed different properties and contributed differently to the prediction of academic performance. Furthermore, the results were in line with the expectation that learning was a predictor of performance in school. PMID:26435760
Action versus state orientation and self-control performance after depletion.
Gröpel, Peter; Baumeister, Roy F; Beckmann, Jürgen
2014-04-01
Three studies investigated the role of action versus state orientation in how people deal with depletion of self-control resources. Action-oriented persons were expected to continue allocating resources and hence to perform better than state-oriented persons who were expected to conserve strength. Consistent with this, action-oriented persons performed better on the d2 test of attention than state-oriented persons after a strenuous physical exercise (Study 1), showed higher acuity on the critical fusion frequency test after a test of vigilance (Study 2), and performed better on the Stroop test after a depleting sensorimotor task (Study 3). No differences emerged between action- and state-oriented persons in their initial performance and in a non-depleting context. The impact of depletion on subsequent performance is thus not fixed, but moderated by personality.
van der Slikke, Rienk M A; de Witte, Annemarie M H; Berger, Monique A M; Bregman, Daan J J; Veeger, Dirk Jan H E J
2018-02-12
The purpose of this study was to provide insight in the effect of wheelchair settings on wheelchair mobility performance. Twenty elite wheelchair basketball athletes of low (n=10) and high classification (n=10), were tested in a wheelchair basketball directed field test. Athletes performed the test in their own wheelchair, which was modified for five additional conditions regarding seat height (high - low), mass (central - distributed) and grip. The previously developed, inertial sensor based wheelchair mobility performance monitor 1 was used to extract wheelchair kinematics in all conditions. Adding mass showed most effect on wheelchair mobility performance, with a reduced average acceleration across all activities. Once distributed, additional mass also reduced maximal rotational speed and rotational acceleration. Elevating seat height had effect on several performance aspects in sprinting and turning, whereas lowering seat height influenced performance minimally. Increased rim grip did not alter performance. No differences in response were evident between low and high classified athletes. The wheelchair mobility performance monitor showed sensitive to detect performance differences due to the small changes in wheelchair configuration made. Distributed additional mass had the most effect on wheelchair mobility performance, whereas additional grip had the least effect of conditions tested. Performance effects appear similar for both low and high classified athletes. Athletes, coaches and wheelchair experts are provided with insight in the performance effect of key wheelchair settings, and they are offered a proven sensitive method to apply in sports practice, in their search for the best wheelchair-athlete combination.
Two-Phase Cryogenic Heat Exchanger for the Thermodynamic Vent System
NASA Technical Reports Server (NTRS)
Christie, Robert J.
2011-01-01
A two-phase cryogenic heat exchanger for a thermodynamic vent system was designed and analyzed, and the predicted performance was compared with test results. A method for determining the required size of the Joule-Thomson device was also developed. Numerous sensitivity studies were performed to show that the design was robust and possessed a comfortable capacity margin. The comparison with the test results showed very similar heat extraction performance for similar inlet conditions. It was also shown that estimates for Joule- Thomson device flow rates and exit quality can vary significantly and these need to be accommodated for with a robust system design.
Krishnan, Anup; Sharma, Deep; Bhatt, Madhu; Dixit, Apoorv; Pradeep, P
2017-04-01
Lower limb explosive power is an important motor quality for sporting performance and indicates use of anaerobic energy systems like stored ATP and Creatine phosphate system. Weightlifting, Fencing and Wrestling use it for monitoring and identification of potential sportsmen. The Wingate test and Standing Broad Jump (SBJ) test are reliable and accurate tests for its assessment. This study conducted on elite Indian sportsmen tries to analyse feasibility of use of the SBJ test in sports and military medicine when Wingate test is impractical. 95 elite sportsmen (51 Fencers, 17 Weight lifters and 27 Wrestlers) of a sports institute were administered Wingate cycle ergometer test and SBJ under standardised conditions. The results were analysed for mass and inter-discipline correlation. Analysis using Pearson's correlation showed significant positive correlation between Peak power ( r = 0.446, p < 0.0001) and SBJ (distance) in all sportsmen. Inter-sport correlation showed positive correlation between SBJ and peak power ( r = 0.335, p < 0.016) in Fencers and between SBJ, peak power ( r = 0.686, p < 0.002) in Weightlifters. Bland-Altman plot analysis showed that about 94% pairs of peak power and SBJ were within limits of agreement for each discipline as well as among all sportsmen. The test results show definite correlation and SBJ test can be used as a field test in performance monitoring, talent identification, military recruit screening and injury prevention.
Evaluation of DuPont Qualicon Bax System PCR assay for yeast and mold.
Wallace, F Morgan; Burns, Frank; Fleck, Lois; Andaloro, Bridget; Farnum, Andrew; Tice, George; Ruebl, Joanne
2010-01-01
Evaluations were conducted to test the performance of the BAX System PCR assay which was certified as Performance Tested Method 010902 for screening yeast and mold in yogurt, corn starch, and milk-based powdered infant formula. Method comparison studies performed on samples with low-level inoculates showed that the BAX System demonstrates a sensitivity equivalent to the U.S. Food and Drug Administration's Bacteriological Analytical Manual culture method, but with a significantly shorter time to obtain results. Tests to evaluate inclusivity and exclusivity returned no false-negative and no false-positive results on a diverse panel of isolates, and tests for lot-to-lot variability and tablet stability demonstrated consistent performance. Ruggedness studies determined that none of the factors examined affected the performance of the assay.
2012-01-01
Backgound Treatment of confirmed malaria patients with Artemisinin-based Combination Therapy (ACT) at remote areas is the goal of many anti-malaria programs. Introduction of effective and affordable malaria Rapid Diagnosis Test (RDT) in remote areas could be an alternative tool for malaria case management. This study aimed to assess performance of the OptiMAL dipstick for rapid malaria diagnosis in children under five. Methods Malaria symptomatic and asymptomatic children were recruited in a passive manner in two community clinics (CCs). Malaria diagnosis by microscopy and RDT were performed. Performance of the tests was determined. Results RDT showed similar ability (61.2%) to accurately diagnose malaria as microscopy (61.1%). OptiMAL showed a high level of sensitivity and specificity, compared with microscopy, during both transmission seasons (high & low), with a sensitivity of 92.9% vs. 74.9% and a specificity of 77.2% vs. 87.5%. Conclusion By improving the performance of the test through accurate and continuous quality control of the device in the field, OptiMAL could be suitable for use at CCs for the management and control of malaria. PMID:22647557
Thermal Performance of Cryogenic Piping Multilayer Insulation in Actual Field Installations
NASA Technical Reports Server (NTRS)
Fesmire, J.; Augustnynowicz, S.; Thompson, K. (Technical Monitor)
2002-01-01
A standardized way of comparing the thermal performance of different pipelines in different sizes is needed. Vendor data for vacuum-insulated piping are typically given in heat leak rate per unit length (W/m) for a specific diameter pipeline. An overall k-value for actual field installations (k(sub oafi)) is therefore proposed as a more generalized measure for thermal performance comparison and design calculation. The k(sub oafi) provides a direct correspondence to the k-values reported for insulation materials and illustrates the large difference between ideal multilayer insulation (MLI) and actual MLI performance. In this experimental research study, a section of insulated piping was tested under cryogenic vacuum conditions, including simulated spacers and bending. Several different insulation systems were tested using a 1-meter-long cylindrical cryostat test apparatus. The simulated spacers tests showed significant degradation in the thermal performance of a given insulation system. An 18-meter-long pipeline test apparatus is now in operation at the Cryogenics Test Laboratory, NASA Kennedy Space Center, for conducting liquid nitrogen thermal performance tests.
Pilot-in-the-Loop CFD Method Development
2017-04-20
the methods on the NAVAIR Manned Flight Simulator. Activities this period During this report period, we implemented the CRAFT CFD code on the...Penn State VLRCROE Flight simulator and performed the first Pilot-in-the-Loop PILCFD tests at Penn State using the COCOA5 clusters. The initial tests...integration of the flight simulator and Penn State computing infrastructure. Initial tests showed slower performance than real-time (3x slower than real
A cross-national study of calculus
NASA Astrophysics Data System (ADS)
Chai, Jun; Friedler, Louis M.; Wolff, Edward F.; Li, Jun; Rhea, Karen
2015-05-01
The results from a cross-national study comparing calculus performance of students at East China Normal University (ECNU) in Shanghai and students at the University of Michigan before and after their first university calculus course are presented. Overall, ECNU significantly outperformed Michigan on both the pre- and post-tests, but the Michigan students showed a larger gain and normalized gain, and hence narrowed the gap. ECNU's superior performance was especially striking on the subset of problems requiring only a pre-calculus background. On those, Michigan's post-test scores were below ECNU's pre-test scores and, indeed, ECNU's higher performance on both the overall pre-test and overall post-test is attributable to its success on these problems.
An Econometric Model of the Scholastic Aptitude Test Performance of State Educational Systems.
ERIC Educational Resources Information Center
Hashway, Robert M.; And Others
1991-01-01
Nationwide data were partitioned into wealth, fiscal policy, fiscal orientation, and Scholastic Aptitude Test (SAT) performance and participation. Largest between-group differences show that low SAT achieving states have a larger percentage of seniors taking the SAT, along with higher per capita income, per pupil expenditures, and teacher…
NASA Technical Reports Server (NTRS)
Barth, Andrew; Mamich, Harvey; Hoelscher, Brian
2015-01-01
The first test flight of the Orion Multi-Purpose Crew Vehicle presented additional challenges for guidance, navigation and control as compared to a typical re-entry from the International Space Station or other Low Earth Orbit. An elevated re-entry velocity and steeper flight path angle were chosen to achieve aero-thermal flight test objectives. New IMU's, a GPS receiver, and baro altimeters were flight qualified to provide the redundant navigation needed for human space flight. The guidance and control systems must manage the vehicle lift vector in order to deliver the vehicle to a precision, coastal, water landing, while operating within aerodynamic load, reaction control system, and propellant constraints. Extensive pre-flight six degree-of-freedom analysis was performed that showed mission success for the nominal mission as well as in the presence of sensor and effector failures. Post-flight reconstruction analysis of the test flight is presented in this paper to show whether that all performance metrics were met and establish how well the pre-flight analysis predicted the in-flight performance.
Thermal and Cycle-Life Behavior of Commercial Li-ion and Li-Polymer Cells
NASA Technical Reports Server (NTRS)
Zimmerman, Albert H.; Quinzio, M. V.
2001-01-01
Accelerated and real-time LEO cycle-life test data will be presented for a range of commercial Li-ion and Li-polymer (gel type) cells indicating the ranges of performance that can be obtained, and the performance screening tests that must be done to assure long life. The data show large performance variability between cells, as well as a highly variable degradation signature during non-cycling periods within the life tests. High-resolution Dynamic Calorimetry data will be presented showing the complex series of reactions occurring within these Li cells as they are cycled. Data will also be presented for cells being tested using an Adaptive Charge Control Algorithm (ACCA) that continuously adapts itself to changes in cell performance, operation, or environment to both find and maintain the optimum recharge over life. The ACCA has been used to prevent all unneeded overcharge for Li cells, NiCd cells and NiH2 cells. While this is important for all these cell types, it is most critical for Li-ion cells, which are not designed with electrochemical tolerance for overcharge.
Tank Applied Testing of Load-Bearing Multilayer Insulation (LB-MLI)
NASA Technical Reports Server (NTRS)
Johnson, Wesley L.; Valenzuela, Juan G.; Feller, Jerr; Plachta, Dave
2014-01-01
The development of long duration orbital cryogenic storage systems will require the reduction of heat loads into the storage tank. In the case of liquid hydrogen, complete elimination of the heat load at 20 K is currently impractical due to the limitations in lift available on flight cryocoolers. In order to reduce the heat load, without having to remove heat at 20 K, the concept of Reduced Boil-Off uses cooled shields within the insulation system at approximately 90 K. The development of Load-Bearing Multilayer Insulation (LB-MLI) allowed the 90 K shield with tubing and cryocooler attachments to be suspended within the MLI and still be structurally stable. Coupon testing both thermally and structurally were performed to verify that the LB-MLI should work at the tank applied level. Then tank applied thermal and structural (acoustic) testing was performed to demonstrate the functionality of the LB-MLI as a structural insulation system. The LB-MLI showed no degradation of thermal performance due to the acoustic testing and showed excellent thermal performance when integrated with a 90 K class cryocooler on a liquid hydrogen tank.
Tank Applied Testing of Load-Bearing Multilayer Insulation (LB-MLI)
NASA Technical Reports Server (NTRS)
Johnson, Wesley L.; Valenzuela, Juan G.; Feller, Jeffrey R.; Plachta, David W.
2014-01-01
The development of long duration orbital cryogenic storage systems will require the reduction of heat loads into the storage tank. In the case of liquid hydrogen, complete elimination of the heat load at 20 K is currently impractical due to the limitations in lift available on flight cryocoolers. In order to reduce the heat load, without having to remove heat at 20 K, the concept of Reduced Boil-Off uses cooled shields within the insulation system at approximately 90 K. The development of Load-Bearing Multilayer Insulation (LB-MLI) allowed the 90 K shield with tubing and cryocooler attachments to be suspended within the MLI and still be structurally stable. Coupon testing, both thermal and structural was performed to verify that the LB-MLI should work at the tank applied level. Then tank applied thermal and structural (acoustic) testing was performed to demonstrate the functionality of the LB-MLI as a structural insulation system. The LB-MLI showed no degradation of thermal performance due to the acoustic testing and showed excellent thermal performance when integrated with a 90 K class cryocooler on a liquid hydrogen tank.
Effects of a Novel Whitening Formulation on Dental Enamel.
Takesh, Thair; Sargsyan, Anik; Anbarani, Afarin; Ho, Jessica; Wilder-Smith, Petra
2017-04-01
The goal of this study was to evaluate the enamel whitening effects of 2 new test formulations, one of which was a rinse, and the other a whitening strip. Forty enamel chips were prepared from 20 healthy extracted teeth (2 from each tooth). After pre-staining and colorimetry to measure L* and b* values, 20 matched samples were immersed in either test or control rinses, and then colorimetry was performed again after 1 hr, 2 hr, 3 hr, 6 hr, 12 hr, 24 hr and 48 hrs (Each hour equates to one month of clinical use at the recommended dosage of 1 minute exposure 2 times a day). The remaining 20 matched samples were exposed to the test or control whitening strips and colorimetry was performed every 30 minutes for a total of 10 treatments. Overall, the whitening performance of test and control strips was similar. The test and control rinses had a similar lightening effect over the first 3 hours (equivalent to 3 months of clinical use). Subsequently, the control rinse continued to lighten samples, whereas the test rinse had little further effect. Test and control-whitening strips showed similar effects; over time whitening strips showed a greater lightening effect than whitening rinses.
ERIC Educational Resources Information Center
Baumann, Chris; Hamin
2011-01-01
A nation's culture, competitiveness and economic performance explain academic performance. Partial Least Squares (PLS) testing of 2252 students shows culture affects competitiveness and academic performance. Culture and economic performance each explain 32%; competitiveness 36%. The model predicts academic performance when culture, competitiveness…
Correlations of Platooning Track Test and Wind Tunnel Data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lammert, Michael P.; Kelly, Kenneth J.; Yanowitz, Janet
In this report, the National Renewable Energy Laboratory analyzed results from multiple, independent truck platooning projects to compare and contrast track test results with wind tunnel test results conducted by Lawrence Livermore National Laboratory (LLNL). Some highlights from the report include compiled data, and results from four independent SAE J1321 full-size track test campaigns that were compared to LLNL wind tunnel testing results. All platooning scenarios tested demonstrated significant fuel savings with good correlation relative to following distances, but there are still unanswered questions and clear opportunities for system optimization. NOx emissions showed improvements from NREL tests in 2014 tomore » Auburn tests in 2015 with respect to J1321 platooning track testing of Peloton system. NREL evaluated data from Volpe's Naturalistic Study of Truck Following Behavior, which showed minimal impact of naturalistic background platooning. We found significant correlation between multiple track studies, wind tunnel tests, and computational fluid dynamics, but also showed that there is more to learn regarding close formation and longer-distance effects. We also identified potential areas for further research and development, including development of advanced aerodynamic designs optimized for platooning, measurement of platoon system performance in traffic conditions, impact of vehicle lateral offsets on platooning performance, and characterization of the national potential for platooning based on fleet operational characteristics.« less
NASA Technical Reports Server (NTRS)
Kamman, J. H.; Hall, C. L.
1975-01-01
Two inlet performance tests and one inlet/airframe drag test were conducted in 1969 at the NASA-Ames Research Center. The basic inlet system was two-dimensional, three ramp (overhead), external compression, with variable capture area. The data from these tests were analyzed to show the effects of selected design variables on the performance of this type of inlet system. The inlet design variables investigated include inlet bleed, bypass, operating mass flow ratio, inlet geometry, and variable capture area.
DuPont qualicon BAX system real-time PCR assay for Escherichia coli O157:H7.
Burns, Frank; Fleck, Lois; Andaloro, Bridget; Davis, Eugene; Rohrbeck, Jeff; Tice, George; Wallace, Morgan
2011-01-01
Evaluations were conducted to test the performance of the BAX System Real-Time PCR assay, which was certified as Performance Tested Method 031002 for screening E. coli O157:H7 in ground beef, beef trim, spinach, and lettuce. Method comparison studies performed on samples with low-level inoculates showed that the BAX System demonstrates a sensitivity equivalent or superior to the FDA-BAM and the USDA-FSIS culture methods, but with a significantly shorter time to result. Tests to evaluate inclusivity and exclusivity returned no false-negative and no false-positive results on a diverse panel of isolates, and tests for lot-to-lot variability and tablet stability demonstrated consistent performance. Ruggedness studies determined that none of the factors examined affect the performance of the assay. An accelerated shelf life study determined an initial 36 month shelf life for the test kit.
Baseline performance of solar collectors for NASA Langley solar building test facility
NASA Technical Reports Server (NTRS)
Knoll, R. H.; Johnson, S. M.
1977-01-01
The solar collector field contains seven collector designs. Before operation in the field, the experimental performances (thermal efficiencies) of the seven collector designs were measured in an indoor solar simulator. The resulting data provided a baseline for later comparison with actual field test data. The simulator test results are presented for the collectors as received, and after several weeks of outdoor exposure with no coolant (dry operation). Six of the seven collector designs tested showed substantial reductions in thermal efficiency after dry operation.
Cuzzubbo, Andrea J.; Vaughn, David W.; Nisalak, Ananda; Solomon, Tom; Kalayanarooj, Siripen; Aaskov, John; Dung, Nguyen Minh; Devine, Peter L.
1999-01-01
The performances of the MRL dengue fever virus immunoglobulin M (IgM) capture enzyme-linked immunosorbent assay (ELISA) and the PanBio Dengue Duo IgM capture and IgG capture ELISA were compared. Eighty sera from patients with dengue virus infections, 24 sera from patients with Japanese encephalitis (JE), and 78 sera from patients with nonflavivirus infections, such as malaria, typhoid, leptospirosis, and scrub typhus, were used. The MRL test showed superior sensitivity for dengue virus infections (94 versus 89%), while the PanBio test showed superior specificity for JE (79 versus 25%) and other infections (100 versus 91%). The PanBio ELISA showed better overall performance, as assessed by the sum of sensitivity and specificity (F value). When dengue virus and nonflavivirus infections were compared, F values of 189 and 185 were obtained for the PanBio and MRL tests, respectively, while when dengue virus infections and JE were compared, F values of 168 and 119 were obtained. The results obtained with individual sera in the PanBio and MRL IgM ELISAs showed good correlation, but this analysis revealed that the cutoff value of the MRL test was set well below that of the PanBio test. Comparing the sensitivity and specificity of the tests at different cutoff values (receiver-operator analysis) revealed that the MRL and PanBio IgM ELISAs performed similarly in distinguishing dengue virus from nonflavivirus infections, although the PanBio IgM ELISA showed significantly better distinction between dengue virus infections and JE. The implications of these findings for the laboratory diagnosis of dengue are discussed. PMID:10473522
Miniature sheathed thermocouples for turbine blade temperature measurement
NASA Technical Reports Server (NTRS)
Holanda, R.; Glawe, G. E.; Krause, L. N.
1974-01-01
An investigation was made of sheathed thermocouples for turbine blade temperature measurements. Tests were performed on the Chromel-Alumel sheathed thermocouples with both two-wire and single-wire configurations. Sheath diameters ranged from 0.25 to 0.76 mm, and temperatures ranged from 1080 to 1250 K. Both steady-state and thermal cycling tests were performed for times up to 450 hr. Special-order and commercial-grade thermocouples were tested. The tests showed that special-order single-wire sheathed thermocouples can be obtained that are reliable and accurate with diameters as small as 0.25 mm. However, all samples of 0.25-mm-diameter sheathed commercial-grade two-wire and single-wire thermocouples that were tested showed unacceptable drift rates for long-duration engine testing programs. The drift rates were about 1 percent in 10 hr. A thermocouple drift test is recommended in addition to the normal acceptance tests in order to select reliable miniature sheathed thermocouples for turbine blade applications.
Performance of NACA Eight-stage Axial-flow Compressor Designed on the Basis of Airfoil Theory
NASA Technical Reports Server (NTRS)
Sinnette, John T; Schey, Oscar W; King, J Austin
1943-01-01
The NACA has conducted an investigation to determine the performance that can be obtained from a multistage axial-flow compressor based on airfoil research. A theory was developed; an eight-stage axial-flow compressor was designed, constructed, and tested. The performance of the compressor was determined for speeds from 5000 to 14,000 r.p.m with varying air flow at each speed. Most of the tests were made with air at room temperature. The performance was determined in accordance with the Committee's recommended procedure for testing superchargers. The expected performance was obtained, showing that a multistage compressor of high efficiency can be designed by the application of airfoil theory.
Bond, A Elizabeth; Bodger, Owen; Skibinski, David O F; Jones, D Hugh; Restall, Colin J; Dudley, Edward; van Keulen, Geertje
2013-01-01
Multiple-choice question (MCQ) examinations are increasingly used as the assessment method of theoretical knowledge in large class-size modules in many life science degrees. MCQ-tests can be used to objectively measure factual knowledge, ability and high-level learning outcomes, but may also introduce gender bias in performance dependent on topic, instruction, scoring and difficulty. The 'Single Answer' (SA) test is often used in which students choose one correct answer, in which they are unable to demonstrate partial knowledge. Negatively marking eliminates the chance element of guessing but may be considered unfair. Elimination testing (ET) is an alternative form of MCQ, which discriminates between all levels of knowledge, while rewarding demonstration of partial knowledge. Comparisons of performance and gender bias in negatively marked SA and ET tests have not yet been performed in the life sciences. Our results show that life science students were significantly advantaged by answering the MCQ test in elimination format compared to single answer format under negative marking conditions by rewarding partial knowledge of topics. Importantly, we found no significant difference in performance between genders in either cohort for either MCQ test under negative marking conditions. Surveys showed that students generally preferred ET-style MCQ testing over SA-style testing. Students reported feeling more relaxed taking ET MCQ and more stressed when sitting SA tests, while disagreeing with being distracted by thinking about best tactics for scoring high. Students agreed ET testing improved their critical thinking skills. We conclude that appropriately-designed MCQ tests do not systematically discriminate between genders. We recommend careful consideration in choosing the type of MCQ test, and propose to apply negative scoring conditions to each test type to avoid the introduction of gender bias. The student experience could be improved through the incorporation of the elimination answering methods in MCQ tests via rewarding partial and full knowledge.
Bond, A. Elizabeth; Bodger, Owen; Skibinski, David O. F.; Jones, D. Hugh; Restall, Colin J.; Dudley, Edward; van Keulen, Geertje
2013-01-01
Multiple-choice question (MCQ) examinations are increasingly used as the assessment method of theoretical knowledge in large class-size modules in many life science degrees. MCQ-tests can be used to objectively measure factual knowledge, ability and high-level learning outcomes, but may also introduce gender bias in performance dependent on topic, instruction, scoring and difficulty. The ‘Single Answer’ (SA) test is often used in which students choose one correct answer, in which they are unable to demonstrate partial knowledge. Negatively marking eliminates the chance element of guessing but may be considered unfair. Elimination testing (ET) is an alternative form of MCQ, which discriminates between all levels of knowledge, while rewarding demonstration of partial knowledge. Comparisons of performance and gender bias in negatively marked SA and ET tests have not yet been performed in the life sciences. Our results show that life science students were significantly advantaged by answering the MCQ test in elimination format compared to single answer format under negative marking conditions by rewarding partial knowledge of topics. Importantly, we found no significant difference in performance between genders in either cohort for either MCQ test under negative marking conditions. Surveys showed that students generally preferred ET-style MCQ testing over SA-style testing. Students reported feeling more relaxed taking ET MCQ and more stressed when sitting SA tests, while disagreeing with being distracted by thinking about best tactics for scoring high. Students agreed ET testing improved their critical thinking skills. We conclude that appropriately-designed MCQ tests do not systematically discriminate between genders. We recommend careful consideration in choosing the type of MCQ test, and propose to apply negative scoring conditions to each test type to avoid the introduction of gender bias. The student experience could be improved through the incorporation of the elimination answering methods in MCQ tests via rewarding partial and full knowledge. PMID:23437081
NASA Technical Reports Server (NTRS)
Greer, H. D.
1972-01-01
The present paper summarizes the high-angle-of-attack characteristics of a number of high-performance aircraft as determined from model force tests and free-flight model tests and correlates these characteristics with the dynamic directional-stability parameter. This correlation shows that the dynamic directional-stability parameter correlates fairly well with directional divergence. Data are also presented to show the effect of some airframe modifications on the directional divergence potential of the configuration. These results show that leading-edge slates seem to be the most effective airframe modification for reducing or eliminating the directional divergence potential of aircraft with moderately swept wings.
Bartlett, John M S; Ibrahim, Merdol; Jasani, Bharat; Morgan, John M; Ellis, Ian; Kay, Elaine; Magee, Hilary; Barnett, Sarah; Miller, Keith
2007-07-01
Trastuzumab provides clinical benefit for advanced and early breast cancer patients whose tumours over-express or have gene amplification of the HER2 oncogene. The UK National External Quality Assessment Scheme (NEQAS) for immunohistochemical testing was established to assess and improve the quality of HER2 immunohistochemical testing. However, until recently, no provision was available for HER2 fluorescence in situ hybridisation (FISH) testing. A pilot scheme was set up to review the performance of FISH testing in clinical diagnostic laboratories. FISH was performed in 6 reference and 31 participating laboratories using a cell line panel with known HER2 status. Using results from reference laboratories as a criterion for acceptable performance, 60% of all results returned by participants were appropriate and 78% either appropriate or acceptable. However, 22.4% of results returned were deemed inappropriate, including 13 cases (4.2%) where a misdiagnosis would have been made had these been clinical specimens. The results of three consecutive runs show that both reference laboratories and a proportion of routine clinical diagnostic (about 25%) centres can consistently achieve acceptable quality control of HER2 testing. Data from a significant proportion of participating laboratories show that further steps are required, including those taken via review of performance under schemes such as NEQAS, to improve quality of HER2 testing by FISH in the "real world".
DOE Office of Scientific and Technical Information (OSTI.GOV)
Messner, Mark C.; Sham, Sam; Wang, Yanli
This report summarizes the experiments performed in FY17 on Gr. 91 steels. The testing of Gr. 91 has technical significance because, currently, it is the only approved material for Class A construction that is strongly cyclic softening. Specific FY17 testing includes the following activities for Gr. 91 steel. First, two types of key feature testing have been initiated, including two-bar thermal ratcheting and Simplified Model Testing (SMT). The goal is to qualify the Elastic – Perfectly Plastic (EPP) design methodologies and to support incorporation of these rules for Gr. 91 into the ASME Division 5 Code. The preliminary SMT testmore » results show that Gr. 91 is most damaging when tested with compression hold mode under the SMT creep fatigue testing condition. Two-bar thermal ratcheting test results at a temperature range between 350 to 650o C were compared with the EPP strain limits code case evaluation, and the results show that the EPP strain limits code case is conservative. The material information obtained from these key feature tests can also be used to verify its material model. Second, to provide experimental data in support of the viscoplastic material model development at Argonne National Laboratory, selective tests were performed to evaluate the effect of cyclic softening on strain rate sensitivity and creep rates. The results show the prior cyclic loading history decreases the strain rate sensitivity and increases creep rates. In addition, isothermal cyclic stress-strain curves were generated at six different temperatures, and a nonisothermal thermomechanical testing was also performed to provide data to calibrate the viscoplastic material model.« less
Gonzalo-Skok, Oliver; Tous-Fajardo, Julio; Valero-Campo, Carlos; Berzosa, César; Bataller, Ana Vanessa; Arjol-Serrano, José Luis; Moras, Gerard; Mendez-Villanueva, Alberto
2017-08-01
To analyze the effects of 2 different eccentric-overload training (EOT) programs, using a rotational conical pulley, on functional performance in team-sport players. A traditional movement paradigm (ie, squat) including several sets of 1 bilateral and vertical movement was compared with a novel paradigm including a different exercise in each set of unilateral and multi-directional movements. Forty-eight amateur or semiprofessional team-sport players were randomly assigned to an EOT program including either the same bilateral vertical (CBV, n = 24) movement (squat) or different unilateral multidirectional (VUMD, n = 24) movements. Training programs consisted of 6 sets of 1 exercise (CBV) or 1 set of 6 exercises (VUMD) × 6-10 repetitions with 3 min of passive recovery between sets and exercises, biweekly for 8 wk. Functional-performance assessment included several change-of-direction (COD) tests, a 25-m linear-sprint test, unilateral multidirectional jumping tests (ie, lateral, horizontal, and vertical), and a bilateral vertical-jump test. Within-group analysis showed substantial improvements in all tests in both groups, with VUMD showing more robust adaptations in pooled COD tests and lateral/horizontal jumping, whereas the opposite occurred in CBV respecting linear sprinting and vertical jumping. Between-groups analyses showed substantially better results in lateral jumps (ES = 0.21), left-leg horizontal jump (ES = 0.35), and 10-m COD with right leg (ES = 0.42) in VUMD than in CBV. In contrast, left-leg countermovement jump (ES = 0.26) was possibly better in CBV than in VUMD. Eight weeks of EOT induced substantial improvements in functional-performance tests, although the force-vector application may play a key role to develop different and specific functional adaptations.
Cognitive performance deficits in a simulated climb of Mount Everest - Operation Everest II
NASA Technical Reports Server (NTRS)
Kennedy, R. S.; Dunlap, W. P.; Banderet, L. E.; Smith, M. G.; Houston, C. S.
1989-01-01
Cognitive function at simulated altitude was investigated in a repeated-measures within-subject study of performance by seven volunteers in a hypobaric chamber, in which atmospheric pressure was systematically lowered over a period of 40 d to finally reach a pressure equivalent to 8845 m, the approximate height of Mount Everest. The automated performance test system employed compact computer design; automated test administrations, data storage, and retrieval; psychometric properties of stability and reliability; and factorial richness. Significant impairments of cognitive function were seen for three of the five tests in the battery; on two tests, grammatical reasoning and pattern comparison, every subject showed a substantial decrement.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Todd, L.L.; Savage, R.T.; Vincent, R.L.
1983-01-01
The United States Army Aviation Engineering Flight Activity conducted level flight performance tests of the AH-1S (Prod) helicopter to provide data to determine the most fuel efficient operating conditions. Hot and cold weather test sites were used to extend the range of the advancing tip Mach number data to supplement existing AH-1S performance data. Preliminary analysis of non-dimensional data identifies the effects of compressibility on performance and shows a power penalty of as much as 6% at a high NR/theta. The power required characteristics determined by these tests can be combined with engine performance to determine the most fuel efficientmore » operating conditions.« less
Solid polymer electrolyte (SPE) fuel cell technology program, phase 2/2A. [testing and evaluations
NASA Technical Reports Server (NTRS)
1976-01-01
Test evaluations were performed on a fabricated single solid polymer electrolyte cell unit. The cell operated at increased current density and at higher performance levels. This improved performance was obtained through a combination of increased temperature, increased reactant pressures, improved activation techniques and improved thermal control over the baseline cell configuration. The cell demonstrated a higher acid content membrane which resulted in increased performance. Reduced catalyst loading and low cost membrane development showed encouraging results.
Performance comparison of Islamic and commercial banks in Malaysia
NASA Astrophysics Data System (ADS)
Azizud-din, Azimah; Hussin, Siti Aida Sheikh; Zahid, Zalina
2016-10-01
The steady growth in the size and increase in the number of Islamic banks show that the Islamic banking system is considered as an alternative to the conventional banking system. Due to this, comparisons in term of performance measurements and evaluation of the financial health for both type of banks are essential. The main purpose of this study is to analyse the differences between Islamic and commercial banks performance. Five years secondary data were collected from the annual report for each bank. Return on Asset ratio is chosen as the dependent variable, while capital adequacy, asset quality, management quality, earning, liquidity and sensitivity to market risk (CAMELS) are the independent variables. Descriptive analyses were done to understand the data. The independent t-test and Mann Whitney test show the differences of Islamic and commercial banks based on the financial variables. The stepwise and hierarchical multiple regressions were used to determine the factor that affects profitability performance of banks. Results show that Islamic banks are better in term of profitability performance, earning power performance, liquidity performance and sensitive to market risk. The factors that affect profitability performance are capital adequacy, earning power and liquidity variable.
McDermott, Ashley F; Rose, Maya; Norris, Troy; Gordon, Eric
2016-01-28
This study tested a novel feed-forward modeling (FFM) system as a nonpharmacological intervention for the treatment of ADHD children and the training of cognitive skills that improve academic performance. This study implemented a randomized, controlled, parallel design comparing this FFM with a nonpharmacological community care intervention. Improvements were measured on parent- and clinician-rated scales of ADHD symptomatology and on academic performance tests completed by the participant. Participants were followed for 3 months after training. Participants in the FFM training group showed significant improvements in ADHD symptomatology and academic performance, while the control group did not. Improvements from FFM were sustained 3 months later. The FFM appeared to be an effective intervention for the treatment of ADHD and improving academic performance. This FFM training intervention shows promise as a first-line treatment for ADHD while improving academic performance. © The Author(s) 2016.
Cognition, personality, and stress in budgerigars, Melopsittacus undulatus.
Medina-García, Angela; Jawor, Jodie M; Wright, Timothy F
2017-01-01
To study the fitness effects of individual variation in cognitive traits, it is paramount to understand whether traits such as personality and physiological stress influence cognitive performance. We first tested whether budgerigars showed both consistent personalities and cognitive performance across time and tasks. We tested object and food neophobia, and exploratory behavior. We measured cognitive performance in habituation, ability to solve foraging problems, spatial memory, and seed discrimination tasks. Budgerigars showed consistency in their neophobic tendencies and these tendencies were associated with their exploratory behavior. Birds were also consistent in how they performed in most of the cognitive tasks (temporal consistency), but were not consistent in their performance across tasks (context consistency). Neither corticosterone levels (baseline and stress-induced) showed a significant relationship with either cognitive or personality measures. Neophobic and exploratory tendencies determined the willingness of birds to engage only in the seed discrimination task. Such tendencies also had a significant effect on problem-solving ability. Our results suggest that consistent individual differences in cognitive performance along with consistent differences in personality could determine response to environmental change and therefore have important fitness consequences.
NASA Technical Reports Server (NTRS)
Glasgow, S. D.; Kittredge, K. B.
2003-01-01
A thermal interface material is one of the many tools often used as part of the thermal control scheme for space-based applications. Historically, at Marshall Space Flight Center, CHO-THERM 1671 has primarily been used for applications where an interface material was deemed necessary. However, numerous alternatives have come on the market in recent years. It was decided that a number of these materials should be tested against each other to see if there were better performing alternatives. The tests were done strictly to compare the thermal performance of the materials relative to each other under repeatable conditions and do not take into consideration other design issues, such as off-gassing, electrical conduction, isolation, etc. The purpose of this Technical Memorandum is to detail the materials tested, test apparatus, procedures, and results of these tests. The results show that there are a number of better performing alternatives now available.
How Explicit and Implicit Test Instructions in an Implicit Learning Task Affect Performance
Witt, Arnaud; Puspitawati, Ira; Vinter, Annie
2013-01-01
Typically developing children aged 5 to 8 years were exposed to artificial grammar learning. Following an implicit exposure phase, half of the participants received neutral instructions at test while the other half received instructions making a direct, explicit reference to the training phase. We first aimed to assess whether implicit learning operated in the two test conditions. We then evaluated the differential impact of age on learning performances as a function of test instructions. The results showed that performance did not vary as a function of age in the implicit instructions condition, while age effects emerged when explicit instructions were employed at test. However, performance was affected differently by age and the instructions given at test, depending on whether the implicit learning of short or long units was assessed. These results suggest that the claim that the implicit learning process is independent of age needs to be revised. PMID:23326409
Predicting Performance in Higher Education Using Proximal Predictors.
Niessen, A Susan M; Meijer, Rob R; Tendeiro, Jorge N
2016-01-01
We studied the validity of two methods for predicting academic performance and student-program fit that were proximal to important study criteria. Applicants to an undergraduate psychology program participated in a selection procedure containing a trial-studying test based on a work sample approach, and specific skills tests in English and math. Test scores were used to predict academic achievement and progress after the first year, achievement in specific course types, enrollment, and dropout after the first year. All tests showed positive significant correlations with the criteria. The trial-studying test was consistently the best predictor in the admission procedure. We found no significant differences between the predictive validity of the trial-studying test and prior educational performance, and substantial shared explained variance between the two predictors. Only applicants with lower trial-studying scores were significantly less likely to enroll in the program. In conclusion, the trial-studying test yielded predictive validities similar to that of prior educational performance and possibly enabled self-selection. In admissions aimed at student-program fit, or in admissions in which past educational performance is difficult to use, a trial-studying test is a good instrument to predict academic performance.
Silva, Paula F. S.; Quintino, Ludmylla F.; Franco, Juliane; Faria, Christina D. C. M.
2014-01-01
Background Subjects with neurological disease (ND) usually show impaired performance during sit-to-stand and stand-to-sit tasks, with a consequent reduction in their mobility levels. Objective To determine the measurement properties and feasibility previously investigated for clinical tests that evaluate sit-to-stand and stand-to-sit in subjects with ND. Method A systematic literature review following the PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) protocol was performed. Systematic literature searches of databases (MEDLINE/SCIELO/LILACS/PEDro) were performed to identify relevant studies. In all studies, the following inclusion criteria were assessed: investigation of any measurement property or the feasibility of clinical tests that evaluate sit-to-stand and stand-to-sit tasks in subjects with ND published in any language through December 2012. The COSMIN checklist was used to evaluate the methodological quality of the included studies. Results Eleven studies were included. The measurement properties/feasibility were most commonly investigated for the five-repetition sit-to-stand test, which showed good test-retest reliability (Intraclass Correlation Coefficient:ICC=0.94-0.99) for subjects with stroke, cerebral palsy and dementia. The ICC values were higher for this test than for the number of repetitions in the 30-s test. The five-repetition sit-to-stand test also showed good inter/intra-rater reliabilities (ICC=0.97-0.99) for stroke and inter-rater reliability (ICC=0.99) for subjects with Parkinson disease and incomplete spinal cord injury. For this test, the criterion-related validity for subjects with stroke, cerebral palsy and incomplete spinal cord injury was, in general, moderate (correlation=0.40-0.77), and the feasibility and safety were good for subjects with Alzheimer's disease. Conclusions The five-repetition sit-to-stand test was used more often in subjects with ND, and most of the measurement properties were investigated and showed adequate results. PMID:24839043
NASA Astrophysics Data System (ADS)
Abou Eid, Mahear A.
There are many challenges faced with the use of Portland Cement Concrete (PCC) in cold regions, but with the inclusion of new technologies such as steel fibers and recycled tire crumb rubber efficient construction may be possible. Research was conducted on a modified concrete material that included both steel fibers and crumb rubber. The composite material was called Steel Fiber-Reinforced Rubberized Concrete (SFRRC). The objective of this investigation was to provide evidence showing that SFRRC can reduce tire rutting compared to asphaltic pavement. In addition, the research showed that the SFRRC could withstand freeze-thaw cycles and increase service life of roadways. Several tests were performed to determine the characteristics of the material. Freeze-thaw testing was performed to determine compressive strength loss and visual deterioration of the material. Wheel tracker rut testing was performed both with the standard steel wheel and with a modified studded rubber tire to determine plastic deformation and rut resistance. An experimental test slab was cast in place on a public approach to observe the construction procedures, the effects of studded tire wear and the frost actions in cold region conditions. Based on freeze-thaw and wheel tracker test results and observations of the experimental test slab, the SFRRC material shows viability in cold regions for resisting freeze-thaw actions. The freeze-thaw testing resulted in increased compressive strength after 300 freeze-thaw cycles and very low deterioration of material compared to standard PCC. The wheel tracker testing resulted in very low plastic deformation and minor material rutting with use of the studded rubber tire. The test slab showed very minor surface wear, no freeze-thaw cracking and no rutting after one winter of use. It is recommended that further testing of the material be conducted by means of a large-scale trial section. This would provide information with respect to cost analysis and integration of the material into the Department of Transportation construction program.
The development of a performance-enhancing additive for vapor-compression heat pumps
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grzyll, L.R.; Scaringe, R.P.; Gottschlich, J.M.
1997-12-31
This paper describes the testing results of a vapor-compression heat pump operating with HFC-134a refrigerant and a performance-enhancing additive. Preliminary bench-top testing of this additive, when added to polyolester (POE) lubricant and HFC-134a refrigerant, showed surprising enhancements to system COP. To further investigate this finding, the authors designed and fabricated a vapor-compression heat pump test stand for the 3--5 ton range. The authors investigated the effect of different concentrations of this additive on various system performance parameters such as cooling capacity, compressor power requirement, pressure ratio, compressor pressure difference, compressor isentropic efficiency, refrigerant flow rate, and heat exchanger performance. Themore » authors investigated various heat source and heat sink conditions to simulate air-conditioning and heat pump operating conditions. To investigate the effect of this additive on compressor lubrication and life, the authors performed compressor life tests (with scroll and reciprocating compressors), and had lubrication wear tests performed with various concentrations of the additive in the POE lubricant.« less
Williamson, A M; Feyer, A M; Mattick, R P; Friswell, R; Finlay-Brown, S
2001-05-01
The effects of 28 h of sleep deprivation were compared with varying doses of alcohol up to 0.1% blood alcohol concentration (BAC) in the same subjects. The study was conducted in the laboratory. Twenty long-haul truck drivers and 19 people not employed as professional drivers acted as subjects. Tests were selected that were likely to be affected by fatigue, including simple reaction time, unstable tracking, dual task, Mackworth clock vigilance test, symbol digit coding, visual search, sequential spatial memory and logical reasoning. While performance effects were seen due to alcohol for all tests, sleep deprivation affected performance on most tests, but had no effect on performance on the visual search and logical reasoning tests. Some tests showed evidence of a circadian rhythm effect on performance, in particular, simple reaction time, dual task, Mackworth clock vigilance, and symbol digit coding, but only for response speed and not response accuracy. Drivers were slower but more accurate than controls on the symbol digit test, suggesting that they took a more conservative approach to performance of this test. This study demonstrated which tests are most sensitive to sleep deprivation and fatigue. The study therefore has established a set of tests that can be used in evaluations of fatigue and fatigue countermeasures.
Simultaneous Dual Species Matter Wave Interferometry
NASA Astrophysics Data System (ADS)
Schlippert, Dennis; Albers, Henning; Richardson, Logan; Meiners, Christian; Hartwig, Jonas; Ertmer, Wolfgang; Rasel, Ernst
2014-05-01
We report on the first realization of a simultaneous 39K-87Rb-dual species matter wave interferometer measuring gravitational acceleration with the aim to test Einstein's Equivalence Principle (EEP). Compared to classical tests such as torsion pendulum experiments and Lunar Laser Ranging, chemical elements suitable for performing matter wave interferometry can provide complementary information. We show the performance of our apparatus and discuss current limitations and future improvements towards highly sensitive matter wave tests of EEP.
Efficient statistical tests to compare Youden index: accounting for contingency correlation.
Chen, Fangyao; Xue, Yuqiang; Tan, Ming T; Chen, Pingyan
2015-04-30
Youden index is widely utilized in studies evaluating accuracy of diagnostic tests and performance of predictive, prognostic, or risk models. However, both one and two independent sample tests on Youden index have been derived ignoring the dependence (association) between sensitivity and specificity, resulting in potentially misleading findings. Besides, paired sample test on Youden index is currently unavailable. This article develops efficient statistical inference procedures for one sample, independent, and paired sample tests on Youden index by accounting for contingency correlation, namely associations between sensitivity and specificity and paired samples typically represented in contingency tables. For one and two independent sample tests, the variances are estimated by Delta method, and the statistical inference is based on the central limit theory, which are then verified by bootstrap estimates. For paired samples test, we show that the estimated covariance of the two sensitivities and specificities can be represented as a function of kappa statistic so the test can be readily carried out. We then show the remarkable accuracy of the estimated variance using a constrained optimization approach. Simulation is performed to evaluate the statistical properties of the derived tests. The proposed approaches yield more stable type I errors at the nominal level and substantially higher power (efficiency) than does the original Youden's approach. Therefore, the simple explicit large sample solution performs very well. Because we can readily implement the asymptotic and exact bootstrap computation with common software like R, the method is broadly applicable to the evaluation of diagnostic tests and model performance. Copyright © 2015 John Wiley & Sons, Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peipho, R.R.; Dougan, D.R.
1981-01-01
Experience has shown that the grinding characteristics of low rank coals are best determined by testing them in a pulverizer. Test results from a small MPS-32 Babcock and Wilcox pulverizer to predict large, full-scale pulverizer performance are presented. The MPS-32 apparatus, test procedure and evaluation of test results is described. The test data show that the Hardgrove apparatus and the ASTM test method must be used with great caution when considering low-rank fuels. The MPS-32 meets the needs for real-machine simulation but with some disadvantages. A smaller pulverizer is desirable. 1 ref.
The De-Escalating Aggressive Behaviour Scale: development and psychometric testing.
Nau, Johannes; Halfens, Ruud; Needham, Ian; Dassen, Theo
2009-09-01
This paper is a report of a study to develop and test the psychometric properties of a scale measuring nursing students' performance in de-escalation of aggressive behaviour. Successful training should lead not merely to more knowledge and amended attitudes but also to improved performance. However, the quality of de-escalation performance is difficult to assess. Based on a qualitative investigation, seven topics pertaining to de-escalating behaviour were identified and the wording of items tested. The properties of the items and the scale were investigated quantitatively. A total of 1748 performance evaluations by students (rater group 1) from a skills laboratory were used to check distribution and conduct a factor analysis. Likewise, 456 completed evaluations by de-escalation experts (rater group 2) of videotaped performances at pre- and posttest were used to investigate internal consistency, interrater reliability, test-retest reliability, effect size and factor structure. Data were collected in 2007-2008 in German. Factor analysis showed a unidimensional 7-item scale with factor loadings ranging from 0.55 to 0.81 (rater group 1) and 0.48 to 0.88 (rater group 2). Cronbach's alphas of 0.87 and 0.88 indicated good internal consistency irrespective of rater group. A Pearson's r of 0.80 confirmed acceptable test-retest reliability, and interrater reliability Intraclass Correlation 3 ranging from 0.77 to 0.93 also showed acceptable results. The effect size r of 0.53 plus Cohen's d of 1.25 indicates the capacity of the scale to detect changes in performance. Further research is needed to test the English version of the scale and its validity.
Slow crack growth test method for polyethylene gas pipes. Volume 1. Topical report, December 1992
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leis, B.; Ahmad, J.; Forte, T.
1992-12-01
In spite of the excellent performance record of polyethylene (PE) pipes used for gas distribution, a small number of leaks occur in distribution systems each year because of slow growth of cracks through pipe walls. The Slow Crack Growth Test (SCG) has been developed as a key element in a methodology for the assessment of the performance of polyethylene gas distribution systems to resist such leaks. This tropical report describes work conducted in the first part of the research directed at the initial development of the SCG test, including a critical evaluation of the applicability of the SCG test asmore » an element in PE gas pipe system performance methodology. Results of extensive experiments and analysis are reported. The results show that the SCG test should be very useful in performance assessment.« less
NASA Astrophysics Data System (ADS)
Kauppinen, Timo; Siikanen, Sami
2011-05-01
The improvement of energy efficiency is the key issue after the energy performance of buildings directive came into the force in European Union countries. The city of Kuopio participate a project, in which different tools will be used, generated and tested to improve the energy efficiency of public buildings. In this project there are 2 schools, the other consuming much more heating energy than the other same type of school. In this paper the results of the thermography in normal conditions and under 50 Pa pressure drop will be presented; as well as the results of remote controlled air tightness test of the buildings. Thermography combined with air tightness test showed clearly the reasons of specific consumption differences of heating energy - also in the other hand, the measurements showed the problems in the performance of ventilation system. Thermography, air tightness test and other supporting measurements can be used together to solve energy loss problems - if these measurements will be carried out by proper way.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Angers, Crystal Plume; Bottema, Ryan; Buckley, Les
Purpose: Treatment unit uptime statistics are typically used to monitor radiation equipment performance. The Ottawa Hospital Cancer Centre has introduced the use of Quality Control (QC) test success as a quality indicator for equipment performance and overall health of the equipment QC program. Methods: Implemented in 2012, QATrack+ is used to record and monitor over 1100 routine machine QC tests each month for 20 treatment and imaging units ( http://qatrackplus.com/ ). Using an SQL (structured query language) script, automated queries of the QATrack+ database are used to generate program metrics such as the number of QC tests executed and themore » percentage of tests passing, at tolerance or at action. These metrics are compared against machine uptime statistics already reported within the program. Results: Program metrics for 2015 show good correlation between pass rate of QC tests and uptime for a given machine. For the nine conventional linacs, the QC test success rate was consistently greater than 97%. The corresponding uptimes for these units are better than 98%. Machines that consistently show higher failure or tolerance rates in the QC tests have lower uptimes. This points to either poor machine performance requiring corrective action or to problems with the QC program. Conclusions: QATrack+ significantly improves the organization of QC data but can also aid in overall equipment management. Complimenting machine uptime statistics with QC test metrics provides a more complete picture of overall machine performance and can be used to identify areas of improvement in the machine service and QC programs.« less
Integrating Oil Debris and Vibration Gear Damage Detection Technologies Using Fuzzy Logic
NASA Technical Reports Server (NTRS)
Dempsey, Paula J.; Afjeh, Abdollah A.
2002-01-01
A diagnostic tool for detecting damage to spur gears was developed. Two different measurement technologies, wear debris analysis and vibration, were integrated into a health monitoring system for detecting surface fatigue pitting damage on gears. This integrated system showed improved detection and decision-making capabilities as compared to using individual measurement technologies. This diagnostic tool was developed and evaluated experimentally by collecting vibration and oil debris data from fatigue tests performed in the NASA Glenn Spur Gear Fatigue Test Rig. Experimental data were collected during experiments performed in this test rig with and without pitting. Results show combining the two measurement technologies improves the detection of pitting damage on spur gears.
Relationships between field performance tests in high-level soccer players.
Ingebrigtsen, Jørgen; Brochmann, Marit; Castagna, Carlo; Bradley, Paul S; Ade, Jack; Krustrup, Peter; Holtermann, Andreas
2014-04-01
To reduce athlete testing time, the aim of this study was to investigate the relationship between the Yo-Yo intermittent recovery test levels 1 (IR1) and 2 (IR2) performances, maximal sprinting speed (10, 20, and 35 m), repeated sprint ability (RSA; 7 × 35 m), and submaximal heart rates (HRs) after 2 and 4 minutes of the Yo-Yo IR tests by testing 57 high-level soccer players. All players played regularly in one of 3 highest levels of Norwegian soccer and were tested during 3 sessions on 3 consecutive days. Large correlations were observed between Yo-Yo IR1 and IR2 test performances (r = 0.753, p ≤ 0.05). Small and moderate correlations were found between 20- and 35-m sprinting speed and Yo-Yo IR1 performance (r = -0.289 and -0.321, respectively, p ≤ 0.05), whereas 35-m sprinting speed correlated moderately to Yo-Yo IR2 performance (r = -0.371, p ≤ 0.05). Repeated sprint ability at 10, 20, and 35 m all showed moderate to large correlations to Yo-Yo IR1 performance (r = -0.337 to -0.573, p ≤ 0.05). Repeated sprint ability at 20 m (r = -0.348, p ≤ 0.05) and 35 m (r = -0.552, p ≤ 0.01) correlated moderately and largely to Yo-Yo IR2 performance. In addition, moderate and large correlations were found between submaximal Yo-Yo IR1 HRs after 2 (r = -0.483, p ≤ 0.01) and 4 minutes (r = -0.655, p ≤ 0.01) and Yo-Yo IR1 performance, and 2 minutes Yo-Yo IR2 HR and Yo-Yo IR2 performance (r = -0.530, p ≤ 0.01). Intraclass correlation measures of submaximal HR after 2 and 4 minutes of Yo-Yo IR1 test and after 2 minutes of the Yo-Yo IR2 were 0.92 (coefficient of variation [CV] = 4.1%, n = 33), 0.93 (CV = 3.8%, n = 33), and 0.72 (CV = 2.9%, n = 10). Adjusted ordinary least square (OLS) regressions revealed associations (p ≤ 0.05) between sprint speed at 20 and 35 m and Yo-Yo IR1 test performance, but only between 35 m and IR2 test performance (p ≤ 0.05). Further, OLS showed that RSA at 35 m was related to both levels of the Yo-Yo IR test (p ≤ 0.01), and that submaximal HRs after 2 and 4 minutes were independently associated with Yo-Yo IR1 and IR2 performances (p ≤ 0.01). In conclusion, Yo-Yo IR1 and 2 test performances, as well as sprint and RSA performances, correlated very largely, and it may therefore be considered using only one of the Yo-Yo tests and a RSA test, in a general soccer-specific field test protocol. The submaximal HR measures during Yo-Yo tests are reproducible and may be used for frequent, time-efficient, and nonexhaustive testing of intermittent exercise capacity of high-level soccer players.
Lane, Andrew M.; Terry, Peter C.; Devonport, Tracey J.; Friesen, Andrew P.; Totterdell, Peter A.
2017-01-01
The present study tested and extended Lane and Terry (2000) conceptual model of mood-performance relationships using a large dataset from an online experiment. Methodological and theoretical advances included testing a more balanced model of pleasant and unpleasant emotions, and evaluating relationships among emotion regulation traits, states and beliefs, psychological skills use, perceptions of performance, mental preparation, and effort exerted during competition. Participants (N = 73,588) completed measures of trait emotion regulation, emotion regulation beliefs, regulation efficacy, use of psychological skills, and rated their anger, anxiety, dejection, excitement, energy, and happiness before completing a competitive concentration task. Post-competition, participants completed measures of effort exerted, beliefs about the quality of mental preparation, and subjective performance. Results showed that dejection associated with worse performance with the no-dejection group performing 3.2% better. Dejection associated with higher anxiety and anger scores and lower energy, excitement, and happiness scores. The proposed moderating effect of dejection was supported for the anxiety-performance relationship but not the anger-performance relationship. In the no-dejection group, participants who reported moderate or high anxiety outperformed those reporting low anxiety by about 1.6%. Overall, results showed partial support for Lane and Terry’s model. In terms of extending the model, results showed dejection associated with greater use of suppression, less frequent use of re-appraisal and psychological skills, lower emotion regulation beliefs, and lower emotion regulation efficacy. Further, dejection associated with greater effort during performance, beliefs that pre-competition emotions did not assist goal achievement, and low subjective performance. Future research is required to investigate the role of intense emotions in emotion regulation and performance. PMID:28458641
Lane, Andrew M; Terry, Peter C; Devonport, Tracey J; Friesen, Andrew P; Totterdell, Peter A
2017-01-01
The present study tested and extended Lane and Terry (2000) conceptual model of mood-performance relationships using a large dataset from an online experiment. Methodological and theoretical advances included testing a more balanced model of pleasant and unpleasant emotions, and evaluating relationships among emotion regulation traits, states and beliefs, psychological skills use, perceptions of performance, mental preparation, and effort exerted during competition. Participants ( N = 73,588) completed measures of trait emotion regulation, emotion regulation beliefs, regulation efficacy, use of psychological skills, and rated their anger, anxiety, dejection, excitement, energy, and happiness before completing a competitive concentration task. Post-competition, participants completed measures of effort exerted, beliefs about the quality of mental preparation, and subjective performance. Results showed that dejection associated with worse performance with the no-dejection group performing 3.2% better. Dejection associated with higher anxiety and anger scores and lower energy, excitement, and happiness scores. The proposed moderating effect of dejection was supported for the anxiety-performance relationship but not the anger-performance relationship. In the no-dejection group, participants who reported moderate or high anxiety outperformed those reporting low anxiety by about 1.6%. Overall, results showed partial support for Lane and Terry's model. In terms of extending the model, results showed dejection associated with greater use of suppression, less frequent use of re-appraisal and psychological skills, lower emotion regulation beliefs, and lower emotion regulation efficacy. Further, dejection associated with greater effort during performance, beliefs that pre-competition emotions did not assist goal achievement, and low subjective performance. Future research is required to investigate the role of intense emotions in emotion regulation and performance.
NASA Technical Reports Server (NTRS)
Schaefer, Jacob; Hanson, Curt; Johnson, Marcus A.; Nguyen, Nhan
2011-01-01
Three model reference adaptive controllers (MRAC) with varying levels of complexity were evaluated on a high performance jet aircraft and compared along with a baseline nonlinear dynamic inversion controller. The handling qualities and performance of the controllers were examined during failure conditions that induce coupling between the pitch and roll axes. Results from flight tests showed with a roll to pitch input coupling failure, the handling qualities went from Level 2 with the baseline controller to Level 1 with the most complex MRAC tested. A failure scenario with the left stabilator frozen also showed improvement with the MRAC. Improvement in performance and handling qualities was generally seen as complexity was incrementally added; however, added complexity usually corresponds to increased verification and validation effort required for certification. The tradeoff between complexity and performance is thus important to a controls system designer when implementing an adaptive controller on an aircraft. This paper investigates this relation through flight testing of several controllers of vary complexity.
Advanced component testing : Kaskasia handbrake test.
DOT National Transportation Integrated Search
2016-07-01
The evaluation of a prototype remote operation handbrake showed that it can be installed on a car with only minor modifications to connect the air. This prototype did not set the emergency during any of the testing performed. The operation of the pro...
Follow-on cable coupling lightning test, volume 1
NASA Technical Reports Server (NTRS)
Danforth, Richard
1990-01-01
A redesigned solid rocket motor test article was subjected to simulated lightning strikes. This test was performed to evaluate the effects of lightning strike to the redesigned motor and Space Transportation System. The purpose of the test was to evaluate the performance of systems tunnel design changes when subjected to the lightning discharges. The goal of the design changes was to reduce lightning induced coupling to cables within the systems tunnel. The test article was subjected to several different amounts and kinds of discharges. Changes in coupling levels detected during the tests are recorded. The dominant mode of coupling appears to be caused by the diffusion of the magnetic fields through the system tunnel covers. The results from bond strap integrity testing showed that 16 of 18 bond straps survived. Design change evaluations showed that coupling reduction ranged from 0 to 36 decibels for each type of cable. The type of cable has less effect on coupling than does strike location and strike levels. Recommendations for design changes are made.
Event-related potentials and secondary task performance during simulated driving.
Wester, A E; Böcker, K B E; Volkerts, E R; Verster, J C; Kenemans, J L
2008-01-01
Inattention and distraction account for a substantial number of traffic accidents. Therefore, we examined the impact of secondary task performance (an auditory oddball task) on a primary driving task (lane keeping). Twenty healthy participants performed two 20-min tests in the Divided Attention Steering Simulator (DASS). The visual secondary task of the DASS was replaced by an auditory oddball task to allow recording of brain activity. The driving task and the secondary (distracting) oddball task were presented in isolation and simultaneously, to assess their mutual interference. In addition to performance measures (lane keeping in the primary driving task and reaction speed in the secondary oddball task), brain activity, i.e. event-related potentials (ERPs), was recorded. Performance parameters on the driving test and the secondary oddball task did not differ between performance in isolation and simultaneous performance. However, when both tasks were performed simultaneously, reaction time variability increased in the secondary oddball task. Analysis of brain activity indicated that ERP amplitude (P3a amplitude) related to the secondary task, was significantly reduced when the task was performed simultaneously with the driving test. This study shows that when performing a simple secondary task during driving, performance of the driving task and this secondary task are both unaffected. However, analysis of brain activity shows reduced cortical processing of irrelevant, potentially distracting stimuli from the secondary task during driving.
Refsgaard, Louise K; Pickering, Darryl S; Andreasen, Jesper T
2017-02-01
Evidence suggests that N-methyl-D-aspartate receptor (NMDAR) antagonists could be efficacious in treating depression and anxiety, but side effects constitute a challenge. This study evaluated the antidepressant-like and anxiolytic-like actions, and cognitive and motor side effects of four NMDAR antagonists. MK-801, ketamine, S-ketamine, RO 25-6981 and the positive control, citalopram, were tested for antidepressant-like and anxiolytic-like effects in mice using the forced-swim test, the elevated zero maze and the novelty-induced hypophagia test. Side effects were assessed using a locomotor activity test, the modified Y-maze and the rotarod test. All compounds increased swim distance in the forced-swim test. In the elevated zero maze, the GluN2B subtype-selective RO 25-6981 affected none of the measured parameters, whereas all other compounds showed anxiolytic-like effects. In the novelty-induced hypophagia test, citalopram and MK-801 showed anxiogenic-like action. All NMDAR antagonists induced hyperactivity. The high doses of ketamine and MK-801 impaired performance in the modified Y-maze test, whereas S-ketamine and RO 25-6891 showed no effects in this test. Only MK-801 impaired rotarod performance. The study supports that NMDARs could be a possible therapeutic target for treating depression and anxiety. However, selective antagonism of GluN2B subunit-containing NMDARs showed no effect on anxiety-like behaviours in this study.
Oosterholt, Bart G; Maes, Joseph H R; Van der Linden, Dimitri; Verbraak, Marc J P M; Kompier, Michiel A J
2016-05-01
The purpose was to reexamine cognitive performance and cortisol levels of initial clinical burnout patients, non-clinical burnout individuals, and healthy controls. After 1.5-years of the initial measurement, clinical burnout patients showed a reduction of burnout symptoms and general physical and psychological complaints, but these were still elevated compared with controls. Nonetheless, they continued to report cognitive problems and still showed a minor impaired cognitive test performance. However, they no longer reported larger subjective costs associated with cognitive test performance and their cortisol awakening response (CAR) returned to a normal level. Compared with controls, non-clinical burnout individuals still reported the same, elevated, level of burnout symptoms, general physical and psychological complaints, and cognitive problems. Their cognitive test performance and associated subjective costs remained normal. However, they seemed to continue to display a lowered CAR. To conclude, after 1.5-years, clinical burnout patients got better, but not 'well', and non-clinical burnout individuals remained not 'well'. Copyright © 2016 Elsevier B.V. All rights reserved.
Fredriksen, Per Morten; Mamen, Asgeir; Gammelsrud, Heidi; Lindberg, Morten; Hjelle, Ole Petter
2018-05-01
The purpose of this study was to examine factors affecting running performance in children. A cross-sectional study exploring the relationships between height, weight, waist circumference, muscle mass, body fat percentage, relevant biomarkers, and the Andersen intermittent running test in 2272 children aged 6 to 12 years. Parental education level was used as a non-physiological explanatory variable. Mean values (SD) and percentiles are presented as reference values. Height (β = 6.4, p < .0001), high values of haemoglobin (β = 18, p = .013) and low percentage of body fat (β = -7.5, p < .0001) showed an association with results from the running test. In addition, high parental education level showed a positive association with the running test. Boys display better running performance than girls at all age ages, except 7 years old, probably because of additional muscle mass and less fatty tissue. Height and increased level of haemoglobin positively affected running performance. Lower body fat percentage and high parental education level correlated with better running performance.
Scale factor and noise performance tests of the Bendix Corporation Rate Gyro Assembly (RGA)
NASA Astrophysics Data System (ADS)
Kim, R.; Hoffman, J.
1980-08-01
Three Bendix Corporation gyroscopes in a Rate Gyro Assembly (RGA) were tested at the Central Inertial Guidance Test Facility (CIGTF), 6585th Test Group, Holloman Air Force Base, New Mexico, from 29 May through 19 June 1980, for the National Aeronautics and Space Administration (NASA), Marshall Space Flight Center (MSFC), Huntsville, Alabama. The purpose of the tests was to characterize the noise performance of each gyro in the RGA in the frequency range of 0.01 hertz to 20 hertz. Gyro noise performance was then compared with seismic activity and previous results from Bendix Corporation testing. Eight-point tests were performed to obtain scale factors which were used to scale the Power Spectral Density (PSD) data. The PSD test series consisted of 1, 2.5, 5, 40 and 180 minute tests under various operating conditions (wheels on and off, low and high rate modes, and horizontal and vertical output axis orientations). The data are presented as PSD plots in the frequency domain. These results show a negligible seismic contribution and are comparable with data obtained at the Bendix test facility.
Validity of cervical auscultation in the screening for aspiration.
Al Hawat, A; Woisard, V; Perez-Begout, L; Sarrabère, E; Grand, S; Puech, M
2014-01-01
Cervical auscultation could improve the performance of bedside swallowing test to predict aspiration, especially silent aspiration. The aim of this study is to compare the predictive values of bedside swallowing test performed with and without cervical auscultation by logopedist students who had intensive training on cervical auscultation. 64 patients were included in the study. They all underwent swallowing test alone, combined swallowing test and cervical auscultation, and videofluoroscopic swallowing study as defined gold standard. Two logopedist students, at the end of their training, performed the auscultation and noted their results. 128 tests were performed, 96% of the tests were judged positive for aspiration. When comparing the results of the two different clinical tests, the detection of clinical signs is not improved by the addition of auscultation. Using a penetration aspiration scale threshold >5, the area under the curve measured for the swallowing test alone was significantly higher than that measured for the combined tests (p = 0.03) (0.66 for the swallowing test alone (95% CI between 0.49 and 0.83), and 0.50 for the combined tests (95% CI between 0.31 and 0.69). This study showed no advantage in performing cervical auscultation with bedside swallowing test. Cervical auscultation seems to hamper the assessment, mainly the perception of wet voice and laryngeal motion. These results are compatible with literature but need further confirmation using studies performed with trained logopedists.
NASA Technical Reports Server (NTRS)
Bue, Grant; Trevino, Luis; Tsioulos, Gus; Mitchell, Keith; Dillon, Paul; Weaver, Gregg
2009-01-01
The spacesuit water membrane evaporator (SWME) is being developed to perform the thermal control function for advanced spacesuits to take advantage of recent advances in micropore membrane technology in providing a robust heat-rejection device that is potentially less sensitive to contamination than is the sublimator. Principles of a sheet membrane SWME design were demonstrated using a prototypic test article that was tested in a vacuum chamber at JSC in July 1999. The Membrana Celgard X50-215 microporous hollow fiber (HoFi) membrane was selected after recent contamination tests as the superior candidate among commercial alternatives for HoFi SWME prototype development. Although a number of design variants were considered, one that grouped the fiber layers into stacks, which were separated by small spaces and packaged into a cylindrical shape, was deemed best for further development. An analysis of test data showed that eight layer stacks of the HoFi sheets that had good exposure on each side of the stack would evaporate water with high efficiency. A design that has 15,000 tubes, with 18 cm of exposed tubes between headers has been built and tested that meets the size, weight, and performance requirements of the SWME. This full-scale prototype consists of 30 stacks, each of which are formed into a chevron shape and separated by spacers and organized into three sectors of ten nested stacks. Testing has been performed to show contamination resistance to the constituents expected to be found in potable water produced by the distillation processes. Other tests showed the sensitivity to surfactants.
Noise-immune multisensor transduction of speech
NASA Astrophysics Data System (ADS)
Viswanathan, Vishu R.; Henry, Claudia M.; Derr, Alan G.; Roucos, Salim; Schwartz, Richard M.
1986-08-01
Two types of configurations of multiple sensors were developed, tested and evaluated in speech recognition application for robust performance in high levels of acoustic background noise: One type combines the individual sensor signals to provide a single speech signal input, and the other provides several parallel inputs. For single-input systems, several configurations of multiple sensors were developed and tested. Results from formal speech intelligibility and quality tests in simulated fighter aircraft cockpit noise show that each of the two-sensor configurations tested outperforms the constituent individual sensors in high noise. Also presented are results comparing the performance of two-sensor configurations and individual sensors in speaker-dependent, isolated-word speech recognition tests performed using a commercial recognizer (Verbex 4000) in simulated fighter aircraft cockpit noise.
NASA Technical Reports Server (NTRS)
Davis, Richard E.; Maddalon, Dal V.; Wagner, Richard D.; Fisher, David F.; Young, Ronald
1989-01-01
Summary evaluations of the performance of laminar-flow control (LFC) leading edge test articles on a NASA JetStar aircraft are presented. Statistics, presented for the test articles' performance in haze and cloud situations, as well as in clear air, show a significant effect of cloud particle concentrations on the extent of laminar flow. The cloud particle environment was monitored by two instruments, a cloud particle spectrometer (Knollenberg probe) and a charging patch. Both instruments are evaluated as diagnostic aids for avoiding laminar-flow detrimental particle concentrations in future LFC aircraft operations. The data base covers 19 flights in the simulated airline service phase of the NASA Leading-Edge Flight-Test (LEFT) Program.
A study of the transient performance of annular hydrostatic journal bearings in liquid oxygen
NASA Astrophysics Data System (ADS)
Scharrer, J. K.; Tellier, J. G.; Hibbs, R. I.
1992-07-01
A test apparatus was used to simulate a cryogenic turbopump start transient in order to determine the liftoff and touchdown speed and amount of wear of an annular hydrostatic bearing in liquid oxygen. The bearing was made of sterling silver and the journal made of Inconel 718. The target application of this configuration is the pump end bearing of the Space Shuttle Main Engine High Pressure Liquid Oxygen Turbopump. Sixty-one transient cycles were performed in liquid oxygen with an additional three tests in liquid nitrogen to certify the test facility and configuration. The bearing showed no appreciable wear during the testing, and the results indicate that the performance of the bearing was not significantly degraded during the testing.
Experimental Study on the Viscosity and Adhesive Performance of Exogenous Liquid Fibrin Glue
HAYASHI, Takuro; HASEGAWA, Mitsuhiro; INAMASU, Joji; ADACHI, Kazuhide; NAGAHISA, Shinya; HIROSE, Yuichi
2014-01-01
Exogenous fibrin glue (FG) is highly suitable for neurosurgical procedures, because of its viscosity and adhesive properties. Several FGs are commercially available, but only few reports detail their differences. In the present study, we investigated the viscosity and adhesive performance of two types of FG: one is derived from blood donated in Europe and the United States (CSL Behring's Beriplast®, BP) and the other is derived from blood donated in Japan (the Chemo-Sero-Therapeutic Research Institute's Bolheal®, BH). The viscosity test that measured fibrinogen viscosity revealed that BP had significantly higher viscosity than BH. Similarly, the dripping test showed that BP traveled a significantly shorter drip distance in the vertical direction than BH, although the transverse diameter of the coagulated FG did not differ statistically significantly. In the tensile strength test, BP showed superior adhesion performance over BH. The histological study of the hematoxylin-eosin-stained specimens in both groups showed favorable adhesion. Although further studies are required on its manufacturing and usage methods, FG shows differences in viscosity and adhesive performance according to the blood from which it is derived. We conclude that it is desirable to select the type and usage method of FG according to the characteristics of the surgical operation in question. Our findings suggest that FG produced from the blood donated in Europe and the United States might be more suitable for use in surgical procedures that demand an especially high degree of viscosity and rapid adhesive performance. PMID:25367586
Experimental study on the viscosity and adhesive performance of exogenous liquid fibrin glue.
Hayashi, Takuro; Hasegawa, Mitsuhiro; Inamasu, Joji; Adachi, Kazuhide; Nagahisa, Shinya; Hirose, Yuichi
2014-01-01
Exogenous fibrin glue (FG) is highly suitable for neurosurgical procedures, because of its viscosity and adhesive properties. Several FGs are commercially available, but only few reports detail their differences. In the present study, we investigated the viscosity and adhesive performance of two types of FG: one is derived from blood donated in Europe and the United States (CSL Behring's Beriplast(®), BP) and the other is derived from blood donated in Japan (the Chemo-Sero-Therapeutic Research Institute's Bolheal(®), BH). The viscosity test that measured fibrinogen viscosity revealed that BP had significantly higher viscosity than BH. Similarly, the dripping test showed that BP traveled a significantly shorter drip distance in the vertical direction than BH, although the transverse diameter of the coagulated FG did not differ statistically significantly. In the tensile strength test, BP showed superior adhesion performance over BH. The histological study of the hematoxylin-eosin-stained specimens in both groups showed favorable adhesion. Although further studies are required on its manufacturing and usage methods, FG shows differences in viscosity and adhesive performance according to the blood from which it is derived. We conclude that it is desirable to select the type and usage method of FG according to the characteristics of the surgical operation in question. Our findings suggest that FG produced from the blood donated in Europe and the United States might be more suitable for use in surgical procedures that demand an especially high degree of viscosity and rapid adhesive performance.
Considering Horn's Parallel Analysis from a Random Matrix Theory Point of View.
Saccenti, Edoardo; Timmerman, Marieke E
2017-03-01
Horn's parallel analysis is a widely used method for assessing the number of principal components and common factors. We discuss the theoretical foundations of parallel analysis for principal components based on a covariance matrix by making use of arguments from random matrix theory. In particular, we show that (i) for the first component, parallel analysis is an inferential method equivalent to the Tracy-Widom test, (ii) its use to test high-order eigenvalues is equivalent to the use of the joint distribution of the eigenvalues, and thus should be discouraged, and (iii) a formal test for higher-order components can be obtained based on a Tracy-Widom approximation. We illustrate the performance of the two testing procedures using simulated data generated under both a principal component model and a common factors model. For the principal component model, the Tracy-Widom test performs consistently in all conditions, while parallel analysis shows unpredictable behavior for higher-order components. For the common factor model, including major and minor factors, both procedures are heuristic approaches, with variable performance. We conclude that the Tracy-Widom procedure is preferred over parallel analysis for statistically testing the number of principal components based on a covariance matrix.
Rienstra, Anne; Groot, Paul F C; Spaan, Pauline E J; Majoie, Charles B L M; Nederveen, Aart J; Walstra, Gerard J M; de Jonghe, Jos F M; van Gool, Willem A; Olabarriaga, Silvia D; Korkhov, Vladimir V; Schmand, Ben
2013-01-01
Patients with mild cognitive impairment (MCI) do not always convert to dementia. In such cases, abnormal neuropsychological test results may not validly reflect cognitive symptoms due to brain disease, and the usual brain-behavior relationships may be absent. This study examined symptom validity in a memory clinic sample and its effect on the associations between hippocampal volume and memory performance. Eleven of 170 consecutive patients (6.5%; 13% of patients younger than 65 years) referred to memory clinics showed noncredible performance on symptom validity tests (SVTs, viz. Word Memory Test and Test of Memory Malingering). They were compared to a demographically matched group (n = 57) selected from the remaining patients. Hippocampal volume, measured by an automated volumetric method (Freesurfer), was correlated with scores on six verbal memory tests. The median correlation was r = .49 in the matched group. However, the relation was absent (median r = -.11) in patients who failed SVTs. Memory clinic samples may include patients who show noncredible performance, which invalidates their MCI diagnosis. This underscores the importance of applying SVTs in evaluating patients with cognitive complaints that may signify a predementia stage, especially when these patients are relatively young.
Hussain, Husniza; Khalid, Norhayati Mustafa; Selamat, Rusidah; Wan Nazaimoon, Wan Mohamud
2013-09-01
The urinary iodine micromethod (UIMM) is a modification of the conventional method and its performance needs evaluation. UIMM performance was evaluated using the method validation and 2008 Iodine Deficiency Disorders survey data obtained from four urinary iodine (UI) laboratories. Method acceptability tests and Sigma quality metrics were determined using total allowable errors (TEas) set by two external quality assurance (EQA) providers. UIMM obeyed various method acceptability test criteria with some discrepancies at low concentrations. Method validation data calculated against the UI Quality Program (TUIQP) TEas showed that the Sigma metrics were at 2.75, 1.80, and 3.80 for 51±15.50 µg/L, 108±32.40 µg/L, and 149±38.60 µg/L UI, respectively. External quality control (EQC) data showed that the performance of the laboratories was within Sigma metrics of 0.85-1.12, 1.57-4.36, and 1.46-4.98 at 46.91±7.05 µg/L, 135.14±13.53 µg/L, and 238.58±17.90 µg/L, respectively. No laboratory showed a calculated total error (TEcalc)
Hydrogen Field Test Standard: Laboratory and Field Performance
Pope, Jodie G.; Wright, John D.
2015-01-01
The National Institute of Standards and Technology (NIST) developed a prototype field test standard (FTS) that incorporates three test methods that could be used by state weights and measures inspectors to periodically verify the accuracy of retail hydrogen dispensers, much as gasoline dispensers are tested today. The three field test methods are: 1) gravimetric, 2) Pressure, Volume, Temperature (PVT), and 3) master meter. The FTS was tested in NIST's Transient Flow Facility with helium gas and in the field at a hydrogen dispenser location. All three methods agree within 0.57 % and 1.53 % for all test drafts of helium gas in the laboratory setting and of hydrogen gas in the field, respectively. The time required to perform six test drafts is similar for all three methods, ranging from 6 h for the gravimetric and master meter methods to 8 h for the PVT method. The laboratory tests show that 1) it is critical to wait for thermal equilibrium to achieve density measurements in the FTS that meet the desired uncertainty requirements for the PVT and master meter methods; in general, we found a wait time of 20 minutes introduces errors < 0.1 % and < 0.04 % in the PVT and master meter methods, respectively and 2) buoyancy corrections are important for the lowest uncertainty gravimetric measurements. The field tests show that sensor drift can become a largest component of uncertainty that is not present in the laboratory setting. The scale was calibrated after it was set up at the field location. Checks of the calibration throughout testing showed drift of 0.031 %. Calibration of the master meter and the pressure sensors prior to travel to the field location and upon return showed significant drifts in their calibrations; 0.14 % and up to 1.7 %, respectively. This highlights the need for better sensor selection and/or more robust sensor testing prior to putting into field service. All three test methods are capable of being successfully performed in the field and give equivalent answers if proper sensors without drift are used. PMID:26722192
Degidi, Marco; Daprile, Giuseppe; Piattelli, Adriano
The aims of this study were to evaluate the ability of a stepped osteotomy to improve dental implant primary stability in low-density bone sites and to investigate possible correlations between primary stability parameters. The study was performed on fresh humid bovine bone classified as type III. The test group consisted of 30 Astra Tech EV implants inserted following the protocol provided by the manufacturer. The first control group consisted of 30 Astra Tech EV implants inserted in sites without the underpreparation of the apical portion. The second control group consisted of 30 Astra Tech TX implants inserted following the protocol provided by the manufacturer. Implant insertion was performed at the predetermined 30 rpm. The insertion torque data were recorded and exported as a curve; using a trapezoidal integration technique, the area underlying the curve was calculated: this area represents the variable torque work (VTW). Peak insertion torque (pIT) and resonance frequency analysis (RFA) were also recorded. A Mann-Whitney test showed that the mean VTW was significantly higher in the test group compared with the first control and second control groups; furthermore, statistical analysis showed that pIT also was significantly higher in the test group compared with the first and second control groups. Analyzing RFA values, only the difference between the test group and second control group showed statistical significance. Pearson correlation analysis showed a very strong positive correlation between pIT and VTW values in all groups; furthermore, it showed a positive correlation between pIT and RFA values and between VTW and RFA values only in the test group. Within the limitations of an in vitro study, the results show that stepped osteotomy can be a viable method to improve implant primary stability in low-density bone sites, and that, when a traditional osteotomy method is performed, RFA presents no correlation with pIT and VTW.
Gray, Dean; LeVanseler, Kerri; Pan, Meide
2008-01-01
A single laboratory validation (SLV) was completed for a method to determine the flavonol aglycones quercetin, kaempferol, and isorhamnetin in Ginkgo biloba products. The method calculates total glycosides based on these aglycones formed following acid hydrolysis. Nine matrixes were chosen for the study, including crude leaf material, standardized dry powder extract, single and multiple entity finished products, and ethanol and glycerol tinctures. For the 9 matrixes evaluated as part of this SLV, the method appeared to be selective and specific, with no observed interferences. The simplified 60 min oven heating hydrolysis procedure was effective for each of the matrixes studied, with no apparent or consistent differences between 60, 75, and 90 min at 90°C. A Youden ruggedness trial testing 7 factors with the potential to affect quantitative results showed that 2 factors (volume hydrolyzed and test sample extraction/hydrolysis weight) were the most important parameters for control during sample preparation. The method performed well in terms of precision, with 4 matrixes tested in triplicate over a 3-day period showing an overall repeatability (relative standard deviation, RSD) of 2.3%. Analysis of variance testing at α = 0.05 showed no significant differences among the within- or between-group sources of variation, although comparisons of within-day (Sw), between-day (Sb), and total (St) precision showed that a majority of the standard deviation came from within-day determinations for all matrixes. Accuracy testing at 2 levels (approximately 30 and 90% of the determined concentrations in standardized dry powder extract) from 2 complex negative control matrixes showed an overall 96% recovery and RSD of 1.0% for the high spike, and 94% recovery and RSD of 2.5% for the low spike. HorRat scores were within the limits for performance acceptability, ranging from 0.4 to 1.3. Based on the performance results presented herein, it is recommended that this method progress to the collaborative laboratory trial. PMID:16001841
Wu, Jinnan; Mei, Wenjuan; Ugrin, Joseph C
2018-03-01
This study investigates the in-class and out-of-class cyberloafing activities of students in China, and tests the relationship between those activities and academic performance. A sample of 1,050 undergraduate students at a large University in China reported their in-class (N = 548) and out-of-class (N = 502) cyberloafing activities, which were tested against the students' academic performance. The test results show a negative relationship between in-class cyberloafing and academic performance, but an inverted U-shaped relationship between out-of-class cyberloafing and academic performance. The results support our propositions that cyberloafing is a harmful distraction in the classroom, but can have positive effects when performed in moderation outside the classroom as a means of effort recovery.
Testing and Validation of the Dynamic Inertia Measurement Method
NASA Technical Reports Server (NTRS)
Chin, Alexander W.; Herrera, Claudia Y.; Spivey, Natalie D.; Fladung, William A.; Cloutier, David
2015-01-01
The Dynamic Inertia Measurement (DIM) method uses a ground vibration test setup to determine the mass properties of an object using information from frequency response functions. Most conventional mass properties testing involves using spin tables or pendulum-based swing tests, which for large aerospace vehicles becomes increasingly difficult and time-consuming, and therefore expensive, to perform. The DIM method has been validated on small test articles but has not been successfully proven on large aerospace vehicles. In response, the National Aeronautics and Space Administration Armstrong Flight Research Center (Edwards, California) conducted mass properties testing on an "iron bird" test article that is comparable in mass and scale to a fighter-type aircraft. The simple two-I-beam design of the "iron bird" was selected to ensure accurate analytical mass properties. Traditional swing testing was also performed to compare the level of effort, amount of resources, and quality of data with the DIM method. The DIM test showed favorable results for the center of gravity and moments of inertia; however, the products of inertia showed disagreement with analytical predictions.
Validation of powder X-ray diffraction following EN ISO/IEC 17025.
Eckardt, Regina; Krupicka, Erik; Hofmeister, Wolfgang
2012-05-01
Powder X-ray diffraction (PXRD) is used widely in forensic science laboratories with the main focus of qualitative phase identification. Little is found in literature referring to the topic of validation of PXRD in the field of forensic sciences. According to EN ISO/IEC 17025, the method has to be tested for several parameters. Trueness, specificity, and selectivity of PXRD were tested using certified reference materials or a combination thereof. All three tested parameters showed the secure performance of the method. Sample preparation errors were simulated to evaluate the robustness of the method. These errors were either easily detected by the operator or nonsignificant for phase identification. In case of the detection limit, a statistical evaluation of the signal-to-noise ratio showed that a peak criterion of three sigma is inadequate and recommendations for a more realistic peak criterion are given. Finally, the results of an international proficiency test showed the secure performance of PXRD. © 2012 American Academy of Forensic Sciences.
Coagulation parameters in senior athletes practicing endurance sporting activity.
Cerneca, E; Simeone, R; Bruno, G; Gombacci, A
2005-12-01
Physical activity is practiced more and more by middle-aged people. We studied the behavior of the coagulation system before and after near-maximum, specific and standardized exercise tests in 2 groups of senior athletes. The subjects of the study were 2 groups of athletes over 40 years of age (ranging 41 to 60 years): 10 rowers and 10 marathon runners. The data were compared with 10 controls (ranging in age from 40 to 71 years) tested on the cycle ergometer. The first group (rowers) was tested on a rowing machine; the second group (marathon runners) performed a maximal exercise on the treadmill. All subjects were tested to a maximal level of cardiovascular and muscular exertion and cardiac and respiratory parameters were monitored. The following coagulation tests were performed before and after maximal exercise: prothrombin time (PT), partial activated thromboplastin time (PTT), fibrinogen (FBG), antithrombin III (ATIII), protein C (PC), protein S (PS), prothrombin fragment 1+2 (F1+2), tissue activator of plasminogen (t-PA) and its inhibitor (PAI). All subjects performed a complete maximal specific test. The results showed all individuals produced a significant increase of FBG, PT and PTT activities and a lowering trend for PC and PS inhibitors after maximal exercise testing. ATIII levels increased significantly in trained subjects. After the test, data regarding fibrinolysis showed higher t-PA levels in athletes as compared with controls. PAI levels indicated a more marked decrease in athletes. The F1+2 showed a moderate but significant increase in the control group. Coagulative tests showed an increase in procoagulant and fibrinolysis parameters in all the groups but the increased fibrinolytic activity in trained athletes indicates a protective factor and greater vascular efficiency. The results demonstrate that sporting activity practiced by middle-aged people accelerates fibrinolytic activity in conditioned subjects. In conclusion, physical activity benefits the coagulation system particularly as regards fibrinolysis.
Neuropsychology of selective attention and magnetic cortical stimulation.
Sabatino, M; Di Nuovo, S; Sardo, P; Abbate, C S; La Grutta, V
1996-01-01
Informed volunteers were asked to perform different neuropsychological tests involving selective attention under control conditions and during transcranial magnetic cortical stimulation. The tests chosen involved the recognition of a specific letter among different letters (verbal test) and the search for three different spatial orientations of an appendage to a square (visuo-spatial test). For each test the total time taken and the error rate were calculated. Results showed that cortical stimulation did not cause a worsening in performance. Moreover, magnetic stimulation of the temporal lobe neither modified completion time in both verbal and visuo-spatial tests nor changed error rate. In contrast, magnetic stimulation of the pre-frontal area induced a significant reduction in the performance time of both the verbal and visuo-spatial tests always without an increase in the number of errors. The experimental findings underline the importance of the pre-frontal area in performing tasks requiring a high level of controlled attention and suggest the need to adopt an interdisciplinary approach towards the study of neurone/mind interface mechanisms.
de Castro, Marcus Vasconcelos; Bissaco, Márcia Aparecida Silva; Panccioni, Bruno Marques; Rodrigues, Silvia Cristina Martini; Domingues, Andreia Miranda
2014-01-01
In this study, we show the effectiveness of a virtual environment comprising 18 computer games that cover mathematics topics in a playful setting and that can be executed on the Internet with the possibility of player interaction through chat. An arithmetic pre-test contained in the Scholastic Performance Test was administered to 300 children between 7 and 10 years old, including 162 males and 138 females, in the second grade of primary school. Twenty-six children whose scores showed a low level of mathematical knowledge were chosen and randomly divided into the control (CG) and experimental (EG) groups. The EG participated to the virtual environment and the CG participated in reinforcement using traditional teaching methods. Both groups took a post-test in which the Scholastic Performance Test (SPT) was given again. A statistical analysis of the results using the Student's t-test showed a significant learning improvement for the EG and no improvement for the CG (p≤0.05). The virtual environment allows the students to integrate thought, feeling and action, thus motivating the children to learn and contributing to their intellectual development.
Setford, Steven; Smith, Antony; McColl, David; Grady, Mike; Koria, Krisna; Cameron, Hilary
2015-01-01
Assess laboratory and in-clinic performance of the OneTouch Select(®) Plus test system against ISO 15197:2013 standard for measurement of blood glucose. System performance assessed in laboratory against key patient, environmental and pharmacologic factors. User performance was assessed in clinic by system-naïve lay-users. Healthcare professionals assessed system accuracy on diabetes subjects in clinic. The system demonstrated high levels of performance, meeting ISO 15197:2013 requirements in laboratory testing (precision, linearity, hematocrit, temperature, humidity and altitude). System performance was tested against 28 interferents, with an adverse interfering effect only being recorded for pralidoxime iodide. Clinic user performance results fulfilled ISO 15197:2013 accuracy criteria. Subjects agreed that the color range indicator clearly showed if they were low, in-range or high and helped them better understand glucose results. The system evaluated is accurate and meets all ISO 15197:2013 requirements as per the tests described. The color range indicator helped subjects understand glucose results and supports patients in following healthcare professional recommendations on glucose targets.
Cowings, Patricia S; Toscano, William B; Reschke, Millard F; Tsehay, Addis
2018-03-02
The National Aeronautics and Space Administration (NASA) has identified a potential risk of spatial disorientation, motion sickness, and degraded performance to astronauts during re-entry and landing of the proposed Orion crew vehicle. The purpose of this study was to determine if a physiological training procedure, Autogenic-Feedback Training Exercise (AFTE), can mitigate these adverse effects. Fourteen men and six women were assigned to two groups (AFTE, no-treatment Control) matched for motion sickness susceptibility and gender. All subjects received a standard rotating chair test to determine motion sickness susceptibility; three training sessions on a manual performance task; and four exposures in the rotating chair (Orion tests) simulating angular accelerations of the crew vehicle during re-entry. AFTE subjects received 2 h of training before Orion tests 2, 3, and 4. Motion sickness symptoms, task performance, and physiological measures were recorded on all subjects. Results showed that the AFTE group had significantly lower symptom scores when compared to Controls on test 2 (p = .05), test 3 (p = .03), and test 4 (p = .02). Although there were no significant group differences on task performance, trends showed that AFTE subjects were less impaired than Controls. Heart rate change scores (20 rpm minus baseline) of AFTE subjects indicated significantly less reactivity on Test 4 compared to Test 1 (10.09 versus 16.59, p = .02), while Controls did not change significantly across tests. Results of this study indicate that AFTE may be an effective countermeasure for mitigating spatial disorientation and motion sickness in astronauts. Copyright © 2018. Published by Elsevier B.V.
Investigating the Effects of Exam Length on Performance and Cognitive Fatigue
Jensen, Jamie L.; Berry, Dane A.; Kummer, Tyler A.
2013-01-01
This study examined the effects of exam length on student performance and cognitive fatigue in an undergraduate biology classroom. Exams tested higher order thinking skills. To test our hypothesis, we administered standard- and extended-length high-level exams to two populations of non-majors biology students. We gathered exam performance data between conditions as well as performance on the first and second half of exams within conditions. We showed that lengthier exams led to better performance on assessment items shared between conditions, possibly lending support to the spreading activation theory. It also led to greater performance on the final exam, lending support to the testing effect in creative problem solving. Lengthier exams did not result in lower performance due to fatiguing conditions, although students perceived subjective fatigue. Implications of these findings are discussed with respect to assessment practices. PMID:23950918
Absolute pitch in children prior to the beginning of musical training.
Ross, David A; Marks, Lawrence E
2009-07-01
Absolute pitch (AP) is a rare skill, historically defined as the ability to name notes. Until now, methodologic limitations made it impossible to directly test the extent to which the development of AP depends on musical training. Using a new paradigm, we tested children with minimal musical experience. Although most children performed poorly, two performed comparably to adult possessors of AP. Follow-up testing showed that the performance of both children progressed to that of "classic" AP. These data support the theory that AP can result from differences in the encoding of stimulus frequency that are independent of musical experience.
In-pile test results of U-silicide or U-nitride coated U-7Mo particle dispersion fuel in Al
NASA Astrophysics Data System (ADS)
Kim, Yeon Soo; Park, J. M.; Lee, K. H.; Yoo, B. O.; Ryu, H. J.; Ye, B.
2014-11-01
U-silicide or U-nitride coated U-Mo particle dispersion fuel in Al (U-Mo/Al) was in-pile tested to examine the effectiveness of the coating as a diffusion barrier between the U-7Mo fuel kernels and Al matrix. This paper reports the PIE data and analyses focusing on the effectiveness of the coating in terms of interaction layer (IL) growth and general fuel performance. The U-silicide coating showed considerable success, but it also provided evidence for additional improvement for coating process. The U-nitride coated specimen showed largely inefficient results in reducing IL growth. From the test, important observations were also made that can be utilized to improve U-Mo/Al fuel performance. The heating process for coating turned out to be beneficial to suppress fuel swelling. The use of larger fuel particles confirmed favorable effects on fuel performance.
Neuromechanical evidence of improved neuromuscular control around knee joint in volleyball players.
Masci, Ilaria; Vannozzi, Giuseppe; Gizzi, Leonardo; Bellotti, Pasquale; Felici, Francesco
2010-02-01
The aim of the present work was to verify that skilled volleyball players present specific adaptations in both neuromuscular control and movement biomechanics, showing an improved neuromuscular control around the knee joint than in non-jumper athletes. Seven male volleyball players and seven male non-jumper athletes were recruited for this study. The following tests were performed in a random order: single countermovement jump (CMJ), single squat jump. At the end of the series, subjects performed a repetitive CMJ test. Electromyographic signals were recorded from vastus lateralis and biceps femoris muscles on both sides. Ground reaction forces and moments were measured with a force plate. Volleyball athletes performed better in all tests and were more resistant to fatigue than non-jumper athletes. Furthermore, volleyball athletes showed a reduced co-activation of knee flexor/extensor muscles. The present results seem to stand for a neural adaptation of the motor control scheme to training.
Turbomachinery noise studies of the AiResearch QCGAT engine with inflow control
NASA Technical Reports Server (NTRS)
Mcardle, J. G.; Homyak, L.; Chrulski, D. D.
1981-01-01
The AiResearch Quiet Clean General Aviation Turbofan engine was tested on an outdoor test stand to compare the acoustic performance of two inflow control devices (ICD's) of similar design, and three inlet lips of different external shape. Only small performance differences were found. Far-field directivity patterns calculated by applicable existing analyses were compared with the measured tone and broadband patterns. For some of these comparisons, tests were made with an ICD to reduce rotor/inflow disturbance interaction noise, or with the acoustic suppression panels in the inlet or bypass duct covered with aluminum tape to determine hard wall acoustic performance. The comparisons showed that the analytical expressions used predict many directivity pattern features and trends, but can deviate in shape from the measured patterns under certain engine operating conditions. Some patterns showed lobes from modes attributable to rotor/engine strut interaction sources.
Development of safe, green and high performance ionic liquids-based batteries (ILLIBATT project)
NASA Astrophysics Data System (ADS)
Balducci, A.; Jeong, S. S.; Kim, G. T.; Passerini, S.; Winter, M.; Schmuck, M.; Appetecchi, G. B.; Marcilla, R.; Mecerreyes, D.; Barsukov, V.; Khomenko, V.; Cantero, I.; De Meatza, I.; Holzapfel, M.; Tran, N.
This manuscript presents the work carried out within the European project ILLIBATT, which was dedicated to the development of green, safe and high performance ionic liquids-based lithium batteries. Different types of ionic liquids-based electrolytes were developed in the project, based on different ionic liquids and polymers. Using these electrolytes, the performance of several anodic and cathodic materials has been tested and promising results have been obtained. Also, electrodes were formulated using water soluble binders. Using these innovative components, lithium-ion and lithium-metal battery prototypes (0.7-0.8 Ah) have been assembled and cycled between 100% and 0% SOC. The results of these tests showed that such ionic liquids-based prototypes are able to display high capacity, high coulombic efficiency and high cycle life. Moreover, safety tests showed that the introduction of these alternative electrolytes positively contribute to the safety of the batteries.
Lakshminarayan, Nagesh; Potdar, Shrudha; Reddy, Siddana Goud
2013-04-01
Procrastination, generally defined as a voluntary, irrational delay of behavior, is a prevalent phenomenon among college students throughout the world and occurs at alarmingly high rates. For this study, a survey was conducted of 209 second-, third-, and fourth-year undergraduate dental students of Bapuji Dental College and Hospital, Davangere, India, to identify the relationship between their level of procrastination and academic performance. A sixteen-item questionnaire was used to assess the level of procrastination among these students. Data related to their academic performance were also collected. Spearman's correlation coefficient test was used to assess the relationship between procrastination and academic performance. It showed a negative correlation of -0.63 with a significance level of p<0.01 (two-tailed test), indicating that students who showed high procrastination scores performed below average in their academics. In addition, analysis with the Mann-Whitney U test found a significant difference in procrastination scores between the two gender groups (p<0.05). Hence, among the Indian undergraduate dental students evaluated in this study, it appeared that individuals with above average and average academic performance had lower scores of procrastination and vice versa.
Carter, Nathan T; Dalal, Dev K; Boyce, Anthony S; O'Connell, Matthew S; Kung, Mei-Chuan; Delgado, Kristin M
2014-07-01
The personality trait of conscientiousness has seen considerable attention from applied psychologists due to its efficacy for predicting job performance across performance dimensions and occupations. However, recent theoretical and empirical developments have questioned the assumption that more conscientiousness always results in better job performance, suggesting a curvilinear link between the 2. Despite these developments, the results of studies directly testing the idea have been mixed. Here, we propose this link has been obscured by another pervasive assumption known as the dominance model of measurement: that higher scores on traditional personality measures always indicate higher levels of conscientiousness. Recent research suggests dominance models show inferior fit to personality test scores as compared to ideal point models that allow for curvilinear relationships between traits and scores. Using data from 2 different samples of job incumbents, we show the rank-order changes that result from using an ideal point model expose a curvilinear link between conscientiousness and job performance 100% of the time, whereas results using dominance models show mixed results, similar to the current state of the literature. Finally, with an independent cross-validation sample, we show that selection based on predicted performance using ideal point scores results in more favorable objective hiring outcomes. Implications for practice and future research are discussed.
Bloch, Yuval; Aviram, Shai; Segev, Aviv; Nitzan, Uri; Levkovitz, Yechiel; Braw, Yoram; Mimouni Bloch, Aviva
2017-01-01
We hypothesized that patients with ADHD were typified by distress more than by functional difficulties. Thus, a decline in state anxiety while performing a cognitive task when taking methylphenidate would discriminate between ADHD patients and controls. State anxiety and cognitive performance on a continuous performance test were assessed in ADHD patients and controls with and without taking methylphenidate. State anxiety and cognitive performance improved from baseline in 36 ADHD adults after taking methylphenidate. In 25 controls, cognitive performance improved, but state anxiety did not abate after a recess. In two additional studies, 5 controls were evaluated at baseline and after receiving methylphenidate, and showed improvement in cognitive assessment but not in state anxiety. Five ADHD adults were assessed at baseline and after a recess, and showed no improvement. Our results support the hypothesis that adult ADHD patients are characterized by distress and the relief of this distress under effective therapy as expressed by a decline in state anxiety while they perform a cognitive task.
Effect of teaching mathematics using GeoGebra on students' with dissimilar spatial visualisation
NASA Astrophysics Data System (ADS)
Bakar, Kamariah Abu; Ayub, Ahmad Fauzi Mohd; Tarmizi, Rohani Ahmad; Luan, Wong Su
2015-10-01
This study examined the effects of GeoGebra on mathematics performance of students with different spatial visualization. A qusai-experimental, pretest-posttest control group design was conducted. A total of 71 students from two intact groups were involved in the study. They were in two groups and each group was randonly assigned to the experimental group (36 students) and control group (35 students). A spatial visual test to identify students with high or low visualization, and a mathematics performance pre-test were administered at the initial stage of this study. A post-test was administered after 12 weeks of treatment using GeoGebra. Analyses of Covarion (ANCOVA) was used to adjust for the pre-test score. Findings showed that the group with access to GeoGebra achieved significantly better test scores in the posttest as compared to the group which followed the traditional teaching method. A two-way ANCOVA used to analyse the effect of students' spatial visualization on post-test performance showed that there was no effect. The results from this study suggested that using GeoGebra had helped the students to score better in the posttest. However, there is no significance difference on mathematics performances on students with difference types of spatial visualisastion. This study indicates that GeoGebra is useful in enhancing the teaching and learning of mathematics.
Low-temperature irradiation behavior of uranium-molybdenum alloy dispersion fuel
NASA Astrophysics Data System (ADS)
Meyer, M. K.; Hofman, G. L.; Hayes, S. L.; Clark, C. R.; Wiencek, T. C.; Snelgrove, J. L.; Strain, R. V.; Kim, K.-H.
2002-08-01
Irradiation tests have been conducted to evaluate the performance of a series of high-density uranium-molybdenum (U-Mo) alloy, aluminum matrix dispersion fuels. Fuel plates incorporating alloys with molybdenum content in the range of 4-10 wt% were tested. Two irradiation test vehicles were used to irradiate low-enrichment fuels to approximately 40 and 70 at.% 235U burnup in the advanced test reactor at fuel temperatures of approximately 65 °C. The fuel particles used to fabricate dispersion specimens for most of the test were produced by generating filings from a cast rod. In general, fuels with molybdenum contents of 6 wt% or more showed stable in-reactor fission gas behavior, exhibiting a distribution of small, stable gas bubbles. Fuel particle swelling was moderate and decreased with increasing alloy content. Fuel particles with a molybdenum content of 4 wt% performed poorly, exhibiting extensive fuel-matrix interaction and the growth of relatively large fission gas bubbles. Fuel particles with 4 or 6 wt% molybdenum reacted more rapidly with the aluminum matrix than those with higher-alloy content. Fuel particles produced by an atomization process were also included in the test to determine the effect of fuel particle morphology and microstructure on fuel performance for the U-10Mo composition. Both of the U-10Mo fuel particle types exhibited good irradiation performance, but showed visible differences in fission gas bubble nucleation and growth behavior.
The cortisol awakening response and memory performance in older men and women.
Almela, Mercedes; van der Meij, Leander; Hidalgo, Vanesa; Villada, Carolina; Salvador, Alicia
2012-12-01
The activity and regulation of the hypothalamus-pituitary-adrenal axis has been related to cognitive decline during aging. This study investigated whether the cortisol awakening response (CAR) is related to memory performance among older adults. The sample was composed of 88 participants (44 men and 44 women) from 55 to 77 years old. The memory assessment consisted of two tests measuring declarative memory (a paragraph recall test and a word list learning test) and two tests measuring working memory (a spatial span test and a spatial working memory test). Among those participants who showed the CAR on two consecutive days, we found that a greater CAR was related to poorer declarative memory performance in both men and women, and to better working memory performance only in men. The results of our study suggest that the relationship between CAR and memory performance is negative in men and women when memory performance is largely dependent on hippocampal functioning (i.e. declarative memory), and positive, but only in men, when memory performance is largely dependent on prefrontal cortex functioning (i.e. working memory). Copyright © 2012 Elsevier Ltd. All rights reserved.
The Long-Term Performance of Small-Cell Batteries Without Cell-Balancing Electronics
NASA Technical Reports Server (NTRS)
Pearson, C.; Thwaite, C.; Curzon, D.; Rao, G.
2006-01-01
Tests approx.8 yrs ago showed Sony HC do not imbalance. AEA developed a theory (ESPC 2002): a) Self-discharge (SD) decreases with state-of-charge (SOC); b) Cells diverge to a state of dynamic equilibrium; c) Equilibrium spread depends on cell SD uniformity. Balancing model verified against test data. Short-term measures of SD difficult in Sony cells and very small values, depends on technique. Long-term evidence supports lower SD at low SD. Battery testing best proof of performance, typically mission specific tests.
[Cognitive dysfunction in patients with subclinical hypothyroidism].
Fernandes, Robertta Soares Miranda; Alvarenga, Nathália Bueno; Silva, Tamara Inácio da; Rocha, Felipe Filardi da
2011-04-01
Evaluate neuropsychological changes in patients with subclinical hypothyroidism (SH). Cross-sectional study comparing the results of the neuropsychological evaluation of 89 SH patients and 178 individuals without thyroid disease. The participants underwent the following neuropsychological assessment: Conner's Continuous Performance Test (CPT-II), Iowa Gambling Task, Stroop Test, Wisconsin Card Sorting Test (WCST), Verbal Fluency Test (semantic and phonologic categories) and Rey Auditory Verbal Learning Test. Among the neuropsychological tests, patients showed worse performance only in cognitive flexibility (WCST) and the ability to maintain sustained attention (omission errors on the CPT-II). These losses can cause detriments in the daily lives of patients, constituting potential treatment indications.
NASA Technical Reports Server (NTRS)
Wood, Jessica J.; Foster, Lee W.
2013-01-01
A Multilayer Insulation (MLI) and Broad Area Cooling (BAC) shield thermal control system shows promise for long-duration storage of cryogenic propellant. The NASA Cryogenic Propellant Storage and Transfer (CPST) project is investigating the thermal and structural performance of this tank-applied integrated system. The MLI/BAC Shield Acoustic and Thermal Test was performed to evaluate the MLI/BAC shield's structural performance by subjecting it to worst-case launch acoustic loads. Identical thermal tests using Liquid Nitrogen (LN2) were performed before and after the acoustic test. The data from these tests was compared to determine if any degradation occurred in the thermal performance of the system as a result of exposure to the acoustic loads. The thermal test series consisted of two primary components: a passive boil-off test to evaluate the MLI performance and an active cooling test to evaluate the integrated MLI/BAC shield system with chilled vapor circulating through the BAC shield tubes. The acoustic test used loads closely matching the worst-case envelope of all launch vehicles currently under consideration for CPST. Acoustic test results yielded reasonable responses for the given load. The thermal test matrix was completed prior to the acoustic test and successfully repeated after the acoustic test. Data was compared and yielded near identical results, indicating that the MLI/BAC shield configuration tested in this series is an option for structurally implementing this thermal control system concept.
Sawyer, R John; Testa, S Marc; Dux, Moira
2017-01-01
Various research studies and neuropsychology practice organizations have reiterated the importance of developing embedded performance validity tests (PVTs) to detect potentially invalid neurocognitive test data. This study investigated whether measures within the Hopkins Verbal Learning Test - Revised (HVLT-R) and the Brief Visuospatial Memory Test - Revised (BVMT-R) could accurately classify individuals who fail two or more PVTs during routine clinical assessment. The present sample of 109 United States military veterans (Mean age = 52.4, SD = 13.3), all consisted of clinically referred patients and received a battery of neuropsychological tests. Based on performance validity findings, veterans were assigned to valid (n = 86) or invalid (n = 23) groups. Of the 109 patients in the overall sample, 77 were administered the HLVT-R and 75 were administered the BVMT-R, which were examined for classification accuracy. The HVLT-R Recognition Discrimination Index and the BVMT-R Retention Percentage showed good to adequate discrimination with an area under the curve of .78 and .70, respectively. The HVLT-R Recognition Discrimination Index showed sensitivity of .53 with specificity of .93. The BVMT-R Retention Percentage demonstrated sensitivity of .31 with specificity of .92. When used in conjunction with other PVTs, these new embedded PVTs may be effective in the detection of invalid test data, although they are not intended for use in patients with dementia.
NASA Astrophysics Data System (ADS)
Zhao, Guanqi; Zhong, Jun; Wang, Jian; Sham, Tsun-Kong; Sun, Xuhui; Lee, Shuit-Tong
2015-05-01
The hybrids of carbon nanotubes (CNTs) and the supported Ni nanoparticles (NPs) have been studied by scanning transmission X-ray microscopy (STXM) and tested by the hydrolysis reaction of ammonia borane (AB, NH3BH3). Data clearly showed the existence of a strong interaction between Ni NPs and thin CNTs (C-O-Ni bonds), which favored the tunable (buffer) electronic structure of Ni NPs facilitating the catalytic process. The hydrolysis process of AB confirmed the hypothesis that the hybrids with a strong interfacial interaction would show superior catalytic performance, while the hybrids with a weak interfacial interaction show poor performance. Our results provide a wealth of detailed information regarding the electronic structure of the NP-CNT hybrids and provide guidance towards the rational design of high-performance catalysts for energy applications.The hybrids of carbon nanotubes (CNTs) and the supported Ni nanoparticles (NPs) have been studied by scanning transmission X-ray microscopy (STXM) and tested by the hydrolysis reaction of ammonia borane (AB, NH3BH3). Data clearly showed the existence of a strong interaction between Ni NPs and thin CNTs (C-O-Ni bonds), which favored the tunable (buffer) electronic structure of Ni NPs facilitating the catalytic process. The hydrolysis process of AB confirmed the hypothesis that the hybrids with a strong interfacial interaction would show superior catalytic performance, while the hybrids with a weak interfacial interaction show poor performance. Our results provide a wealth of detailed information regarding the electronic structure of the NP-CNT hybrids and provide guidance towards the rational design of high-performance catalysts for energy applications. Electronic supplementary information (ESI) available: Magnified TEM images, high resolution TEM images and the particle size distributions of the samples, the STXM results of a thick tube at different positions, XPS results, stability test. See DOI: 10.1039/c5nr01168j
Rolling, slip and traction measurements on low modulus materials
NASA Technical Reports Server (NTRS)
Tevaarwerk, J. L.
1985-01-01
Traction and wear tests were performed on six low modulus materials (LMM). Three different traction tests were performed to determine the suitability of the material for use as traction rollers. These were the rolling, slip and endurance traction tests. For each material the combination LMM on LMM and LMM on steel were evaluated. Rolling traction test were conducted to determine the load - velocity limits, the rolling traction coefficient of the materials and to establish the type of failures that would result when loading beyond the limit. It was found that in general a simple constant rolling traction coefficient was enough to describe the results of all the test. The slip traction tests revealed that the peak traction coefficients were considerably higher than for lubricated traction contacts. The endurance traction tests were performed to establish the durability of the LMM under conditions of prolonged traction. Wear measurements were performed during and after the test. Energetic wear rates were determined from the wear measurements conducted in the endurance traction tests. These values show that the roller wear is not severe when reasonable levels of traction are transmitted.
New developments in supra-threshold perimetry.
Henson, David B; Artes, Paul H
2002-09-01
To describe a series of recent enhancements to supra-threshold perimetry. Computer simulations were used to develop an improved algorithm (HEART) for the setting of the supra-threshold test intensity at the beginning of a field test, and to evaluate the relationship between various pass/fail criteria and the test's performance (sensitivity and specificity) and how they compare with modern threshold perimetry. Data were collected in optometric practices to evaluate HEART and to assess how the patient's response times can be analysed to detect false positive response errors in visual field test results. The HEART algorithm shows improved performance (reduced between-eye differences) over current algorithms. A pass/fail criterion of '3 stimuli seen of 3-5 presentations' at each test location reduces test/retest variability and combines high sensitivity and specificity. A large percentage of false positive responses can be detected by comparing their latencies to the average response time of a patient. Optimised supra-threshold visual field tests can perform as well as modern threshold techniques. Such tests may be easier to perform for novice patients, compared with the more demanding threshold tests.
ISS and STS Commercial Off-the-Shelf Router Testing
NASA Technical Reports Server (NTRS)
Ivancie, William D.; Bell, Terry L.; Shell, Dan
2002-01-01
This report documents the results of testing performed with commercial off-the-shelf (COTS) routers and Internet Protocols (IPs) to determine if COTS equipment and IP could be utilized to upgrade NASA's current Space Transportation System (STS), the Shuttle, and the International Space Station communication infrastructure. Testing was performed by NASA Glenn Research Center (GRC) personnel within the Electronic Systems Test Laboratory (ESTE) with cooperation from the Mission Operations Directorate (MOD) Qualification and Utilization of Electronic System Technology (QUEST) personnel. The ESTE testing occurred between November 1 and 9, 2000. Additional testing was performed at NASA Glenn Research Center in a laboratory environment with equipment configured to emulate the STS. This report documents those tests and includes detailed test procedures, equipment interface requirements, test configurations and test results. The tests showed that a COTS router and standard Transmission Control Protocols and Internet Protocols (TCP/IP) could be used for both the Shuttle and the Space Station if near-error-free radio links are provided.
Snout allometry in seahorses: insights on optimisation of pivot feeding performance during ontogeny.
Roos, Gert; Van Wassenbergh, Sam; Herrel, Anthony; Adriaens, Dominique; Aerts, Peter
2010-07-01
As juvenile life-history stages are subjected to strong selection, these stages often show levels of performance approaching those of adults, or show a disproportionately rapid increase of performance with age. Although testing performance capacity in aquatic suction feeders is often problematic, in pivot feeders such as seahorses models have been proposed to estimate whether snout length is optimal to minimise the time needed to reach the prey. Here, we investigate whether the same model can also explain the snout lengths in an ontogenetic series of seahorses, explore how pivot feeding kinematics change during ontogeny, and test whether juveniles show disproportionate levels of performance. Our analysis shows that the dimensions of the snout change during ontogeny from short and broad to long and narrow. Model calculations show that the snout lengths of newborn and juvenile seahorses are nearly optimal for minimising prey reach time. However, in juveniles the centre of head rotation in the earth-bound frame of reference is located near the posterior end of the head, whereas in adults it is shifted forward and is located approximately above the eye. Modelling shows that this forward shift in the centre of rotation has the advantage of decreasing the moment of inertia and the torque required to rotate the head, but has the disadvantage of slightly increasing the time needed to reach the prey. Thus, the snout lengths of juvenile seahorses appear to be close to optimal, suggesting that they reach levels of performance close to adult levels, which illustrates the pervasive nature of selection on performance in juveniles.
Aeroacoustic Analysis of Fan Noise Reduction With Increased Bypass Nozzle Area
NASA Technical Reports Server (NTRS)
Woodward, Richard P.; Hughes, Christopher E.; Podboy, Gary G.
2005-01-01
An advanced model turbofan was tested in the NASA Glenn 9-by 15-Foot Low Speed Wind Tunnel (9x15 LSWT) to explore far field acoustic effects of increased bypass nozzle area. This fan stage test was part of the NASA Glenn Fan Broadband Source Diagnostic Test, second entry (SDT2) which acquired aeroacoustic results over a range of test conditions. The baseline nozzle was sized to produce maximum stage performance at cruise condition. However, the wind tunnel testing is conducted near sea level condition. Therefore, in order to simulate and obtain performance at other operating conditions, two additional nozzles were designed and tested one with +5 percent increase in weight flow (+5.4 percent increase in nozzle area compared with the baseline nozzle), sized to simulate the performance at the stage design point (takeoff) condition, and the other with a +7.5 percent increase in weight flow (+10.9 percent increase in nozzle area) sized for maximum weight flow with a fixed nozzle at sea level condition. Measured acoustic benefits with increased nozzle area were very encouraging, showing overall sound power level (OAPWL) reductions of 2 or more dB while the stage thrust actually increased by 2 to 3 percent except for the most open nozzle at takeoff rotor speed where stage performance decreased. Effective perceived noise levels for a 1500 ft engine flyover and 3.35 scale factor showed a similar noise reduction of 2 or more EPNdB. Noise reductions, principally in the level of broadband noise, were observed everywhere in the far field. Laser Doppler Velocimetry measurements taken downstream of the rotor showed that the total turbulent velocity decreased with increasing nozzle flow, which may explain the reduced rotor broadband noise levels.
Brankaer, Carmen; Ghesquière, Pol; De Smedt, Bert
2017-08-01
The ability to compare symbolic numerical magnitudes correlates with children's concurrent and future mathematics achievement. We developed and evaluated a quick timed paper-and-pencil measure that can easily be used, for example in large-scale research, in which children have to cross out the numerically larger of two Arabic one- and two-digit numbers (SYMP Test). We investigated performance on this test in 1,588 primary school children (Grades 1-6) and examined in each grade its associations with mathematics achievement. The SYMP Test had satisfactory test-retest reliability. The SYMP Test showed significant and stable correlations with mathematics achievement for both one-digit and two-digit comparison, across all grades. This replicates the previously observed association between symbolic numerical magnitude processing and mathematics achievement, but extends it by showing that the association is observed in all grades in primary education and occurs for single- as well as multi-digit processing. Children with mathematical learning difficulties performed significantly lower on one-digit comparison and two-digit comparison in all grades. This all suggests satisfactory construct and criterion-related validity of the SYMP Test, which can be used in research, when performing large-scale (intervention) studies, and by practitioners, as screening measure to identify children at risk for mathematical difficulties or dyscalculia.
Effects of a Novel Whitening Formulation on Dental Enamel
Takesh, Thair; Sargsyan, Anik; Anbarani, Afarin; Ho, Jessica; Wilder-Smith, Petra
2017-01-01
Objective The goal of this study was to evaluate the enamel whitening effects of 2 new test formulations, one of which was a rinse, and the other a whitening strip. Materials and Methods Forty enamel chips were prepared from 20 healthy extracted teeth (2 from each tooth). After pre-staining and colorimetry to measure L* and b* values, 20 matched samples were immersed in either test or control rinses, and then colorimetry was performed again after 1 hr, 2 hr, 3 hr, 6 hr, 12 hr, 24 hr and 48 hrs (Each hour equates to one month of clinical use at the recommended dosage of 1 minute exposure 2 times a day). The remaining 20 matched samples were exposed to the test or control whitening strips and colorimetry was performed every 30 minutes for a total of 10 treatments. Results Overall, the whitening performance of test and control strips was similar. The test and control rinses had a similar lightening effect over the first 3 hours (equivalent to 3 months of clinical use). Subsequently, the control rinse continued to lighten samples, whereas the test rinse had little further effect. Conclusion Test and control-whitening strips showed similar effects; over time whitening strips showed a greater lightening effect than whitening rinses. PMID:28706755
A real-time comparison of mercury accumulation on noble metal thin films using gravimetric device
NASA Astrophysics Data System (ADS)
Kabir, K. M. Mohibul; Kandjani, Ahmad Esmaielzadeh; Harrison, Christopher J.; Ippolito, Samuel J.; Sabri, Ylias M.; Bhargava, Suresh K.
2016-12-01
We simultaneously compared and analyzed the mercury sorption and sensing performance of gold, silver, palladium and platinum using quartz crystal microbalance (QCM). Overall, the Au- and Ag-QCM showed superior Hg sensing performance over the Pd- and Pt-counterparts when tested toward a range of concentrations (24-365 ppbv) at various operating temperatures (35-105 °C). However, it was also found that the Hg sensing performance of each metal varied significantly with the operating temperature and is dependent on the concentration tested. For instance, the Ag-QCM exhibited 57% higher response magnitude than the Au-QCM when exposed toward 24 ppbv of Hg0 vapor at 35 °C; however, the opposite trend was observed when the same concentration of Hg0 vapor was tested at 105 °C, with Au-QCM showing 104% higher response magnitudes compared to the Ag-QCM. Moreover, the Ag-QCM showed higher response magnitudes than the Au-QCM for exposure toward 365 ppbv of Hg0 vapor regardless of the operating temperature.
Wire-bending test as a predictor of preclinical performance by dental students.
Kao, E C; Ngan, P W; Wilson, S; Kunovich, R
1990-10-01
Traditional Dental Aptitude Test and academic grade point average have been shown to be poor predictors of clinical performance by dental students. To refine predictors of psychomotor skills, a wire-bending test was given to 105 freshmen at the beginning of their dental education. Grades from seven restorative preclinical courses in their freshman and sophomore years were compared to scores on wire bending and the three traditional predictors: GPA, academic aptitude, and perceptual aptitude scores. Wire-bending scores correlated significantly with six out of seven preclinical restorative courses. The predictive power for preclinical performance was doubled when wire bending was added to traditional predictors in stepwise multiple regression analysis. Wire-bending scores identified students of low performance. These preliminary results suggest that the wire-bending test shows some potential as a screening test for identifying students who may hae psychomotor difficulties, early in their dental education.
ERIC Educational Resources Information Center
Tomic, Welko; Klauer, Karl Josef
1996-01-01
Reports on two training experiments in which it was expected that training in inductive reasoning would transfer to intelligence tests measuring inductive reasoning and on mathematics performance. Shows that transfer on intelligence tests as well as on mathematics performance was linearly dependent on the amount of prior training. (DSK)
High subsonic flow tests of a parallel pipe followed by a large area ratio diffuser
NASA Technical Reports Server (NTRS)
Barna, P. S.
1975-01-01
Experiments were performed on a pilot model duct system in order to explore its aerodynamic characteristics. The model was scaled from a design projected for the high speed operation mode of the Aircraft Noise Reduction Laboratory. The test results show that the model performed satisfactorily and therefore the projected design will most likely meet the specifications.
Bartlett, John M S; Ibrahim, Merdol; Jasani, Bharat; Morgan, John M; Ellis, Ian; Kay, Elaine; Magee, Hilary; Barnett, Sarah; Miller, Keith
2007-01-01
Background and Aims Trastuzumab provides clinical benefit for advanced and early breast cancer patients whose tumours over‐express or have gene amplification of the HER2 oncogene. The UK National External Quality Assessment Scheme (NEQAS) for immunohistochemical testing was established to assess and improve the quality of HER2 immunohistochemical testing. However, until recently, no provision was available for HER2 fluorescence in situ hybridisation (FISH) testing. A pilot scheme was set up to review the performance of FISH testing in clinical diagnostic laboratories. Methods FISH was performed in 6 reference and 31 participating laboratories using a cell line panel with known HER2 status. Results Using results from reference laboratories as a criterion for acceptable performance, 60% of all results returned by participants were appropriate and 78% either appropriate or acceptable. However, 22.4% of results returned were deemed inappropriate, including 13 cases (4.2%) where a misdiagnosis would have been made had these been clinical specimens. Conclusions The results of three consecutive runs show that both reference laboratories and a proportion of routine clinical diagnostic (about 25%) centres can consistently achieve acceptable quality control of HER2 testing. Data from a significant proportion of participating laboratories show that further steps are required, including those taken via review of performance under schemes such as NEQAS, to improve quality of HER2 testing by FISH in the “real world”. PMID:16963466
[Performance and personality of patients with hypersomnia].
Mayer, G; Leonhardt, E
1996-01-01
5 groups of patients with hypersomnia (narcolepsy, posttraumatic, psychophysiologic, idiopathic hypersomnia and circadian sleep-wake disorders) were tested with a battery of psychometric tests (FPI, MMPI, BVND, BIV, Benton, d2, WIP), visual vigilance test, polysomnography and MSLT in order to investigate the context between personality and performance. MSLT showed a range from clear pathologic to borderline sleep latencies among all groups, only patients with posttraumatic hypersomnia and narcolepsy displayed sleep onset REM. Correct results of vigilance tests correlated negatively with performance-motivation and orientation in patients with narcolepsy and posttraumatic hypersomnia, whereas there was positive correlation for patients with idiopathic hypersomnia. In patients with psychophysiologic hypersomnia performance orientation and false reactions correlate negatively. Patients with posttraumatic hypersomnia have better results on d2. Benton and vigilance tests than all other groups. Results of personality diagnosis are similar to those of healthy subjects, while patients with psychophysiologic hypersomnia are more sensible than all other groups with high social fears and the highest disposition among all groups toward somatic complaints. Patients with idiopathic hypersomnia show strong introversion and inhibition. Patients with circadian sleep-wake disorders display the most striking personality disorders, which are most probably sequelae of their strong disease-dependent impairment. The degree of personality disorder seems to be strongly dependent on the duration of the hypersomnias. The assessment of the whole set of tests can only be recommended for patients with psychophysiologic hypersomnia and circadian sleep-wake disorders, a few tests suffice to describe the other groups.
Dubey, Anju; Sonker, Atul; Chaudhary, Rajendra K
2015-01-01
Antibody titration is traditionally performed using a conventional test tube (CTT) method, which is subjected to interlaboratory variations because of a lack of standardization and reproducibility. The aim of this study is to compare newer methods such as get column technology (GCT) and erythrocyte magnetized technology (EMT) for antibody titration in terms of accuracy and precision. Patient serum samples that contained immunoglobin G (IgG) red blood cell (RBC) alloantibodies of a single specificity for Rh or K anitgens were identified during routine transfusion service testing and stored. Titration and scoring were performed separately by and stored. Titration and scoring were performed separately by different laboratory personnel on CTT, GCT, and EMT. Testing was performed a total of three times on each sample. Results were analyzed for accuracy and precision. A total of 50 samples were tested. Only 20 percent of samples tested with GCT shoed titers identical to CTT, whereas 48 percent of samples tested with EMT showed titers identical to CTT. Overall, the mean of th titer difference from CTT was higher using GCT (+0.31) compared with that using EMT (+0.13). Precision shown by CTT was 30 percent, EMT was 76 percent, and GCT was 92 percent on repeat testing. GCT showed higher titer values in comparison with CTT but was found to be the most precise. EMT titers were comparable to CTT, and its precision was intermediate. Further studies to validate this method are required.
Lim, Kelvin O.; Ardekani, Babak A.; Nierenberg, Jay; Butler, Pamela D.; Javitt, Daniel C.; Hoptman, Matthew J.
2007-01-01
Patients with schizophrenia show deficits in several neurocognitive domains. However, the relationship between white matter integrity and performance in these domains is poorly understood. The authors conducted neurocognitive testing and diffusion tensor imaging in 25 patients with schizophrenia. Performance was examined for tests of verbal declarative memory, attention, and executive function. Relationships between fractional anisotropy and cognitive performance were examined by using voxelwise correlational analyses. In each case, better performance on these tasks was associated with higher levels of fractional anisotropy in task-relevant regions. PMID:17074956
Zink, Davor N; Miller, Justin B; Caldwell, Jessica Z K; Bird, Christopher; Banks, Sarah J
2018-06-01
Tests of visuospatial function are often administered in comprehensive neuropsychological evaluations. These tests are generally considered assays of parietal lobe function; however, the neural correlates of these tests, using modern imaging techniques, are not well understood. In the current study we investigated the relationship between three commonly used tests of visuospatial function and lobar cortical thickness in each hemisphere. Data from 374 patients who underwent a neuropsychological evaluation and MRI scans in an outpatient dementia clinic were included in the analysis. We examined the relationships between cortical thickness, as assessed with Freesurfer, and performance on three tests: Judgment of Line Orientation (JoLO), Block Design (BD) from the Fourth edition of the Wechsler Adult Intelligence Scale, and Brief Visuospatial Memory Test-Revised Copy Trial (BVMT-R-C) in patients who showed overall average performance on these tasks. Using a series of multiple regression models, we assessed which lobe's overall cortical thickness best predicted test performance. Among the individual lobes, JoLO performance was best predicted by cortical thickness in the right temporal lobe. BD performance was best predicted by cortical thickness in the right parietal lobe, and BVMT-R-C performance was best predicted by cortical thickness in the left parietal lobe. Performance on constructional tests of visuospatial function appears to correspond best with underlying cortical thickness of the parietal lobes, while performance on visuospatial judgment tests appears to correspond best to temporal lobe thickness. Future research using voxel-wise and connectivity techniques and including more diverse samples will help further understanding of the regions and networks involved in visuospatial tests.
ERIC Educational Resources Information Center
Sackett, Paul R.; Hardison, Chaitra M.; Cullen, Michael J.
2004-01-01
C. M. Steele and J. Aronson (1995) showed that making race salient when taking a difficult test affected the performance of high-ability African American students, a phenomenon they termed stereotype threat. The authors document that this research is widely misinterpreted in both popular and scholarly publications as showing that eliminating…
Numeracy skills of undergraduate entry level nurse, midwife and pharmacy students.
Arkell, Sharon; Rutter, Paul M
2012-07-01
The ability of healthcare professionals to perform basic numeracy and therefore dose calculations competently is without question. Research has primarily focused on nurses, and to a lesser extent doctors, ability to perform this function with findings highlighting poor aptitude. Studies involving pharmacists are few but findings are more positive than other healthcare staff. To determine first year nursing, midwifery and pharmacy students ability to perform basic numeracy calculations. All new undergraduate entrants to nursing, midwifery and pharmacy sat a formative numeracy test within the first two weeks of their first year of study. Test results showed that pharmacy students significantly outperformed midwifery and nursing students on all questions. In turn midwifery students outperformed nurses, although this did not achieve significance. When looking at each cohorts general attitude towards mathematics, pharmacy students were more positive and confident compared to midwifery and nursing students. Pharmacy students expressed greater levels of enjoyment and confidence in performing mathematics and correspondingly showed the greatest proficiency. In contrast nurse, and to a lesser extent midwifery students showed poor performance and low confidence levels. Copyright © 2012 Elsevier Ltd. All rights reserved.
Evaluation of a new computerized psychometric test battery: Effects of zolpidem and caffeine.
Pilli, Raveendranadh; Naidu, Mur; Pingali, Usharani; Shobha, Jc
2013-10-01
To evaluate the effects of centrally active drugs using a new indigenously developed automated psychometric test system and compare the results with that obtained using pencil- and paper-based techniques. The tests were standardized in 24 healthy participants. Reproducibility of the test procedure was evaluated by performing the tests by a single experimenter on two occasions (interday reproducibility). To evaluate the sensitivity of the tests, the effects of zolpidem (5 mg) and caffeine (500 mg) versus placebo were studied in 24 healthy participants in a randomized, double-blind three-way crossover design. Psychometric tests were performed at baseline and at 1, 2, and 3 h after administration of study medication. The effects of zolpidem and caffeine on the psychomotor performance were most pronounced 1 h after administration. At this time, a significant impairment of performance in the simple reaction test (SRT), choice discrimination test (CDT), digit symbol substitution test (DSST), digit vigilance test (DVT), and card sorting test (CST) was observed with zolpidem. In contrast, caffeine showed a significant improvement in performance in CDT and DVT only. The results suggest that the tests of the computerized system are more sensitive and reliable then the pencil and paper tests in detecting the effects of central acting agents and are suitable for use in clinical areas to conduct studies with patients.
Hülür, Gizem; Willis, Sherry L; Hertzog, Christopher; Schaie, K Warner; Gerstorf, Denis
2018-05-01
A growing body of research has examined whether people's judgments of their own memory functioning accurately reflect their memory performance at cross-section and over time. Relatively less is known about whether these judgments are specifically based on memory performance, or reflect general cognitive change. The aim of the present study was to examine longitudinal associations of subjective memory with performance in tests of episodic memory and a wide range of other cognitive tests, including the Wechsler Adult Intelligence Scale-Revised (WAIS-R) Block Design, Comprehension, Digit Span, Digit Symbol, and Vocabulary subtests. We applied latent growth curve models to five occasions over up to 16 years of neuropsychological assessments from 956 participants of the Seattle Longitudinal Study (SLS; 57% women; age at baseline: M = 65.1, SD = 11.4, 38 - 96 years). Results revealed that lower self-reported Frequency of Forgetting was significantly associated with better performance in all cognitive domains at baseline. The baseline correlation of Frequency of Forgetting with memory performance was stronger than its correlations with performance in other cognitive tests. Furthermore, additional analyses with baseline data showed that a latent memory performance factor reliably predicted Frequency of Forgetting after controlling for a general cognitive factor. Over time, steeper increases in Frequency of Forgetting were associated with steeper declines in tests of memory performance and in the Block Design and Digit Symbol subtests. Taken together, these findings suggest that although self-reported Frequency of Forgetting reflects performance in a broad range of other cognitive domains, it also shows some specificity for memory performance. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Conjugating binary systems for spacecraft thermal control
NASA Technical Reports Server (NTRS)
Grodzka, Philomena G.; Dean, William G.; Sisk, Lori A.; Karu, Zain S.
1989-01-01
The materials search was directed to liquid pairs which can form hydrogen bonds of just the right strength, i.e., strong enough to give a high heat of mixing, but weak enough to enable phase change to occur. The cursory studies performed in the area of additive effects indicate that Conjugating Binary (CB) performance can probably be fine-tuned by this means. The Fluid Loop Test Systems (FLTS) tests of candidate CBs indicate that the systems Triethylamine (TEA)/water and propionaldehyde/water show close to the ideal, reversible behavior, at least initially. The Quick Screening Tests QSTs and FLTS tests, however, both suffer from rather severe static due either to inadequate stirring or temperature control. Thus it is not possible to adequately evaluate less than ideal CB performers. Less than ideal performers, it should be noted, may have features that make them better practical CBs than ideal performers. Improvement of the evaluation instrumentation is thus indicated.
Similarity tests of turbine vanes, effects of ceramic thermal barrier coatings
NASA Technical Reports Server (NTRS)
Gladden, H. J.
1980-01-01
The role of material thermal conductivity was analyzed for its effect on the thermal performance of air-cooled gas turbine components coated with a ceramic thermal barrier material when tested at reduced temperatures and pressures. It is shown that the thermal performance can be evaluated reliably at reduced gas and coolant conditions; however, thermal conductivity corrections are required for the data at reduced conditions. Corrections for a ceramic thermal barrier coated vane are significantly different than for an uncoated vane. Comparison of uncorrected test data, therefore, would show erroneously that the thermal barrier coating was ineffective. When thermal conductivity corrections are applied to the test data these data are then shown to be representative of engine data and also show that the thermal barrier coating increases the vane cooling effectiveness by 12.5 percent.
van Loenen, Inge S; Rijnen, Sophie Jm; Bruijn, Jimme; Rutten, Geert-Jan M; Gehring, Karin; Sitskoorn, Margriet M
2018-06-07
There is a growing interest to include evaluations of cognitive performance in the clinical management of patients with Glioblastoma (GBM). However, as changes in cognitive performance of a group may mask changes in individual patients, study results are often difficult to transfer into clinical practice. We focused on the comparison of group versus individual changes in neuropsychological performance of GBM patients after initial surgical treatment. Patients underwent neuropsychological evaluation using CNS Vital Signs one day prior to, and three months after surgery. Two-tailed paired samples t-tests were conducted to assess changes on the group level. Reliable Change Indices (RCIs), that correct for practice effects and imperfect test-retest reliabilities, were used to examine change in individual patients. Cognitive dysfunction was common (>80%) both before and three months after surgery in this sample of 82 GBM patients. Whereas group analyses revealed minimal changes in performance over time, RCIs demonstrated that most patients (89%) showed changes in performance in at least one cognitive domain. Half of these individual patients solely showed improvements, a quarter solely showed declines, and another quarter showed both improvements and declines. This study clearly demonstrates that important individual changes in performance are masked when looking only at group results. Future studies should more often use an individual patient approach to enhance knowledge transfer into clinical practice. Copyright © 2018 The Author(s). Published by Elsevier Inc. All rights reserved.
Fuermaier, Anselm B M; Tucha, Oliver; Koerts, Janneke; Send, Tabea S; Weisbrod, Matthias; Aschenbrenner, Steffen; Tucha, Lara
2018-04-25
Several approaches, ranging from self-ratings of symptoms and impairments to objective neuropsychological testing, have been utilized during clinical evaluation in order to assess symptom and performance validity of individuals with attention-deficit/hyperactivity disorder (ADHD) in adulthood. Motor activity has not been considered yet in this context, which is surprising given that hyperactivity is a prominent characteristic of ADHD. Hence, the goal of the present study was to explore the incremental value of motor activity when assessing the credibility of individuals with adult ADHD at clinical evaluation. Forty-six patients diagnosed with ADHD took part in the study. A simulation design was performed, in which 152 healthy individuals were allocated to either a control condition (n = 36) or one of three simulation conditions (n = 116), the latter requesting participants to feign ADHD. All participants completed a self-rating scale of cognitive functioning and performed a computerized test for vigilance. Body movements were recorded during vigilance testing via a motion tracker attached to the back of the participant's chair. Patients with ADHD reported significantly more pronounced cognitive complaints and performed significantly poorer on the vigilance test than control participants. Simulators of ADHD, as compared to genuine patients, showed excessively low performance on the vigilance test. However, neither self-ratings of cognitive functioning nor measures of motor activity were suitable to distinguish genuine from feigned ADHD. A hierarchical logistic regression model showed that motor activity had no incremental value in detecting feigned ADHD when vigilance test performance has already been considered. Standard neuropsychological tests of vigilance may be useful to measure both performance and credibility of individuals with adult ADHD at clinical evaluation. In contrast, self-reports of symptoms and impairments, as well as measures of body movements, may not support the assessment of credibility in this context.
Validation of Modifications to the ANSR(®) Listeria Method for Improved Ease of Use and Performance.
Caballero, Oscar; Alles, Susan; Le, Quynh-Nhi; Gray, R Lucas; Hosking, Edan; Pinkava, Lisa; Norton, Paul; Tolan, Jerry; Mozola, Mark; Rice, Jennifer; Chen, Yi; Odumeru, Joseph; Ryser, Elliot
2016-01-01
A study was conducted to validate minor reagent formulation, enrichment, and procedural changes to the ANSR(®) Listeria method, Performance-Tested Method(SM) 101202. In order to improve ease of use and diminish risk of amplicon contamination, the lyophilized reagent components were reformulated for increased solubility, thus eliminating the need to mix by pipetting. In the alternative procedure, an aliquot of the lysate is added to lyophilized ANSR reagents, immediately capped, and briefly mixed by vortexing. When three foods (hot dogs, Mexican-style cheese, and cantaloupe) and sponge samples taken from a stainless steel surface were tested, significant differences in performance between the ANSR and U.S. Food and Drug Administration Bacteriological Analytical Manual or U.S. Department of Agriculture, Food Safety and Inspection Service Microbiology Laboratory Guidebook reference culture procedures were seen with hot dogs and Mexican-style cheese after 16 h enrichment, with the reference methods producing more positive results. After 24 h enrichment, however, there were no significant differences in method performance for any of the four matrixes tested. Robustness testing was also conducted, with variations to lysis buffer volume, lysis time, and sample volume having no demonstrable effect on assay results. Accelerated stability testing was carried out over a 10-week period and showed no diminishment in assay performance. A second phase of the study examined performance of the ANSR assay following enrichment in a new medium, LESS Plus broth, designed for use with all food and environmental sample types. With the alternative LESS Plus broth, there were no significant differences in performance between the ANSR method and the reference culture procedures for any of the matrixes tested after either 16 or 24 h enrichment, although 24 h enrichment is recommended for hot dogs due to higher sensitivity. Results of inclusivity and exclusivity testing using LESS Plus broth showed that the ANSR assay is highly specific, with 100% expected results for target and nontarget bacteria.
Super-recognizers: People with extraordinary face recognition ability
Russell, Richard; Duchaine, Brad; Nakayama, Ken
2014-01-01
We tested four people who claimed to have significantly better than ordinary face recognition ability. Exceptional ability was confirmed in each case. On two very different tests of face recognition, all four experimental subjects performed beyond the range of control subject performance. They also scored significantly better than average on a perceptual discrimination test with faces. This effect was larger with upright than inverted faces, and the four subjects showed a larger ‘inversion effect’ than control subjects, who in turn showed a larger inversion effect than developmental prosopagnosics. This indicates an association between face recognition ability and the magnitude of the inversion effect. Overall, these ‘super-recognizers’ are about as good at face recognition and perception as developmental prosopagnosics are bad. Our findings demonstrate the existence of people with exceptionally good face recognition ability, and show that the range of face recognition and face perception ability is wider than previously acknowledged. PMID:19293090
Super-recognizers: people with extraordinary face recognition ability.
Russell, Richard; Duchaine, Brad; Nakayama, Ken
2009-04-01
We tested 4 people who claimed to have significantly better than ordinary face recognition ability. Exceptional ability was confirmed in each case. On two very different tests of face recognition, all 4 experimental subjects performed beyond the range of control subject performance. They also scored significantly better than average on a perceptual discrimination test with faces. This effect was larger with upright than with inverted faces, and the 4 subjects showed a larger "inversion effect" than did control subjects, who in turn showed a larger inversion effect than did developmental prosopagnosics. This result indicates an association between face recognition ability and the magnitude of the inversion effect. Overall, these "super-recognizers" are about as good at face recognition and perception as developmental prosopagnosics are bad. Our findings demonstrate the existence of people with exceptionally good face recognition ability and show that the range of face recognition and face perception ability is wider than has been previously acknowledged.
Felt-Bersma, R J; Klinkenberg-Knol, E C; Meuwissen, S G
1990-06-01
Anal manometry, rectal capacity measurement, and the saline-infusion test were performed in 350 patients, 178 of whom had fecal incontinence and 172 of whom were continent. Anal manometry was also performed in 80 control subjects, whose results were compared with the patients. Women and older patients exhibited lower pressures. Compared with continent patients, incontinent patients had lower anal sphincter pressures at rest and during squeeze, a smaller rectal capacity, and leaked earlier and more with the saline infusion test. Differentiation between incontinent and continent patients was not possible with a single test because there was complete overlap. The maximum squeeze pressure showed the best discrimination. Combining the three tests did not show better discrimination than any individual test. Anal pressure and rectal capacity below the normal range only were found in very few incontinent patients. The authors' study demonstrates that no prediction can be made about continence with anorectal function tests. Therefore, in the individual patient, an abnormal result in one test must be interpreted with caution and only in relationship with other tests, especially when therapeutic surgery is considered.
Testing of tactical performance in youth elite soccer.
Memmert, Daniel
2010-01-01
This is a twofold study with the goals of evaluating tactical oriented game test situations for 12-13-year old highly-talented soccer players and to analyze dynamic, intra-individual developments of the players. A cross-sectional design was carried in study 1, using game test situations to measure specific tactics and creative performance for 195 expert players. The results from five evaluation criteria show that both diagnostic instruments can be used for recording football-specific creativity and game intelligence in talented young players. They produced tactical indicators that can be described as objective and valid, exhibit a sufficient degree of differentiation and are easy to record. Study 2 uses a longitudinal design to present a dynamic performance diagnostic tool for analyzing intra-individual improvements of German Soccer Foundation talents according to football-specific creativity and game intelligence. The results with respect to divergent tactical thinking clearly show that very different change processes were observed in the German Soccer Foundation players. Finally, the practical implications for the training process are discussed on the basis of both studies. Key pointsWith game test situations it is possible to assess tactical performance as game intelligence and creativity objective, valid, with a sufficient degree of differentiation, and economically.The results with respect to game intelligence and creativity show that very different change processes were observed in the German Soccer Foundation players dependend on the bases (trainers).Current literature on tactics for school sports as well as for children's, youth and high performance soccer at the club level should place much more emphasis on individual and group-tactical requirements in soccer.
Testing of Tactical Performance in Youth Elite Soccer
2010-01-01
This is a twofold study with the goals of evaluating tactical oriented game test situations for 12-13-year old highly-talented soccer players and to analyze dynamic, intra-individual developments of the players. A cross-sectional design was carried in study 1, using game test situations to measure specific tactics and creative performance for 195 expert players. The results from five evaluation criteria show that both diagnostic instruments can be used for recording football-specific creativity and game intelligence in talented young players. They produced tactical indicators that can be described as objective and valid, exhibit a sufficient degree of differentiation and are easy to record. Study 2 uses a longitudinal design to present a dynamic performance diagnostic tool for analyzing intra-individual improvements of German Soccer Foundation talents according to football-specific creativity and game intelligence. The results with respect to divergent tactical thinking clearly show that very different change processes were observed in the German Soccer Foundation players. Finally, the practical implications for the training process are discussed on the basis of both studies. Key points With game test situations it is possible to assess tactical performance as game intelligence and creativity objective, valid, with a sufficient degree of differentiation, and economically. The results with respect to game intelligence and creativity show that very different change processes were observed in the German Soccer Foundation players dependend on the bases (trainers). Current literature on tactics for school sports as well as for children’s, youth and high performance soccer at the club level should place much more emphasis on individual and group-tactical requirements in soccer. PMID:24149686
Mitsutake, Tsubasa; Sakamoto, Maiko; Ueta, Kozo; Oka, Shinichiro; Horikawa, Etsuo
2017-09-01
The effects of vestibular rehabilitation on poststroke patients are unknown. This study aimed to investigate whether or not vestibular rehabilitation would improve both the vestibulo-ocular reflex and gait performance of patients with poststroke hemiparesis. Twenty-eight patients with stroke were assigned randomly to either an experimental group (N=14) or a control group (N=14). The experimental group performed the conventional physical therapy for 40 min and vestibular rehabilitation for 20 min, as a 60 min session, during the first 3 weeks and then completed only the conventional intervention for 60 min for the following 3 weeks. The control group performed only the 60 min conventional physical therapy for 6 weeks. Both groups were measured using the gaze stabilization test, the 10 m walking test, the timed up and go test, and the dynamic gait index. Patients were assessed at baseline, and at 3 and 6 weeks. Although the control group showed no significant difference in any outcome measures, the experimental group showed an improvement in gaze stabilization test scoring, which increased significantly after 3 weeks compared with the baseline (P=0.030). The dynamic gait index was also significantly increased after 3 and 6 weeks compared with the baseline (P=0.049 and 0.024, respectively). This study indicated that vestibular rehabilitation might improve poststroke patients' vestibulo-ocular reflex. Moreover, patients might show improved gait performance at least up to 3 weeks after the vestibular intervention by the sensory reweight to coordinate vestibular input.
NASA Technical Reports Server (NTRS)
Mehta, Manish; Seaford, Mark; Kovarik, Brian; Dufrene, Aaron; Solly, Nathan; Kirchner, Robert; Engel, Carl D.
2014-01-01
The Space Launch System (SLS) base heating test is broken down into two test programs: (1) Pathfinder and (2) Main Test. The Pathfinder Test Program focuses on the design, development, hot-fire test and performance analyses of the 2% sub-scale SLS core-stage and booster element propulsion systems. The core-stage propulsion system is composed of four gaseous oxygen/hydrogen RS-25D model engines and the booster element is composed of two aluminum-based model solid rocket motors (SRMs). The first section of the paper discusses the motivation and test facility specifications for the test program. The second section briefly investigates the internal flow path of the design. The third section briefly shows the performance of the model RS-25D engines and SRMs for the conducted short duration hot-fire tests. Good agreement is observed based on design prediction analysis and test data. This program is a challenging research and development effort that has not been attempted in 40+ years for a NASA vehicle.
Scaling effects in direct shear tests
Orlando, A.D.; Hanes, D.M.; Shen, H.H.
2009-01-01
Laboratory experiments of the direct shear test were performed on spherical particles of different materials and diameters. Results of the bulk friction vs. non-dimensional shear displacement are presented as a function of the non-dimensional particle diameter. Simulations of the direct shear test were performed using the Discrete Element Method (DEM). The simulation results show Considerable differences with the physical experiments. Particle level material properties, such as the coefficients of static friction, restitution and rolling friction need to be known a priori in order to guarantee that the simulation results are an accurate representation of the physical phenomenon. Furthermore, laboratory results show a clear size dependency on the results, with smaller particles having a higher bulk friction than larger ones. ?? 2009 American Institute of Physics.
Status of the Boeing Dish Engine Critical Component Project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brau, H.W.; Diver, R.B.; Nelving, H.
1999-01-08
The Boeing Company's Dish Engine Critical Component (DECC) project started in April of 1998. It is a continuation of a solar energy program started by McDonnell Douglas (now Boeing) and United Stirling of Sweden in the mid 1980s. The overall objectives, schedule, and status of this project are presented in this paper. The hardware test configuration, hardware background, operation, and test plans are also discussed. A summary is given of the test data, which includes the daily power performance, generated energy, working-gas usage, mirror reflectivity, solar insolation, on-sun track time, generating time, and system availability. The system performance based uponmore » the present test data is compared to test data from the 1984/88 McDonnell Douglas/United Stirling AB/Southem California Edison test program. The test data shows that the present power, energy, and mirror performance is comparable to when the hardware was first manufactured 14 years ago.« less
Status of the Boeing Dish Engine Critical Component project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stone, K.W.; Nelving, H.; Braun, H.W.
1999-07-01
The Boeing Company's Dish Engine Critical Component (DECC) project started in April of 1998. It is a continuation of a solar energy program started by McDonnel Douglas (now Boeing) and United Stirling of Sweden in the mid 1980s. The overall objectives, schedule, and status of this project are presented in this paper. The hardware test configuration, hardware background, operation, and test plans are also discussed. A summary is given of the test data, which includes the daily power performance, generated energy, working-gas usage, mirror reflectivity, solar insolation, on-sun track time. Generating time, and system availability. The system performance based uponmore » the present test data is compared to test data from the 1984/88 McDonnel Douglas/United Stirling AB/Southern California Edison test program. The test data shows that the present power, energy, and mirror performance is comparable to when the hardware was first manufactured 14 years ago.« less
NASA Technical Reports Server (NTRS)
Zachary, A. T.; Csomor, A.; Tignac, L. L.
1973-01-01
Small, high-performance LO2 and LH2 turbopump assembly configurations were selected, detail designs were prepared and two of each unit were fabricated with each unit consisting of pump, turbine gas generator, and appropriate controls. Following fabrication, development testing was conducted on each type to demonstrate performance, durability, transient characteristics, and heat transfer under simulated altitude conditions. Following successful completion of development effort, the two LO2 turbopump units and one LH2 turbopump unit were acceptance tested as specified. Inspection of the units following development testing revealed no deleterious effects of testing. The test results of LO2 turbopump assembly testing correlated well with predicted performance while the LH2 turbopump test results, though generally consistent with predicted values, did show lower than anticipated developed head at the design point and in the high flow range of operation.
Rattanabannakit, Chatchawan; Risacher, Shannon L; Gao, Sujuan; Lane, Kathleen A; Brown, Steven A; McDonald, Brenna C; Unverzagt, Frederick W; Apostolova, Liana G; Saykin, Andrew J; Farlow, Martin R
2016-01-01
The perception of cognitive decline by individuals and those who know them well ("informants") has been inconsistently associated with objective cognitive performance, but strongly associated with depressive symptoms. We investigated associations of self-report, informant-report, and discrepancy between self- and informant-report of cognitive decline obtained from the Cognitive Change Index (CCI) with cognitive test performance and self-reported depressive symptoms. 267 participants with normal cognition, mild cognitive impairment (MCI), or mild dementia were included from a cohort study and memory clinic. Association of test performance and self-rated depression (Geriatric Depression Scale, GDS) with CCI scores obtained from subjects (CCI-S), their informants (CCI-I), and discrepancy scores between subjects and informants (CCI-D; CCI-S minus CCI-I) were analyzed using correlation and analysis of covariance (ANCOVA) models. CCI-S and CCI-I scores showed high internal consistency (Cronbach alpha 0.96 and 0.98, respectively). Higher scores on CCI-S and CCI-I, and lower scores on the CCI-D, were associated with lower performance on various cognitive tests in both univariate and in ANCOVA models adjusted for age, gender, and education. Adjustment for GDS slightly weakened the relationships between CCI and test performance but most remained significant. Self- and informant-report of cognitive decline, as measured by the CCI, show moderately strong relationships with objective test performance independent of age, gender, education, and depressive symptoms. The CCI appears to be a valid cross-sectional measure of self and informant perception of cognitive decline across the continuum of functioning. Studies are needed to address the relationship of CCI scores to longitudinal outcome.
Technical and physical determinants of soccer match-play performance in elite youth soccer players.
Rowat, Owain; Fenner, Jonathan; Unnithan, Viswanath
2017-04-01
The aim of this study was to evaluate whether physical performance characteristics could be a better predictor than technical skills in determining the technical level of county soccer players in a match situation. With institutional ethics approval, 25 male youth soccer players aged 16-18.5 years from a professional soccer academy in South East Asia were selected and height and body mass were recorded. Players were tested for sexual maturity (pubertal development scale [PDS] self-assessment), aerobic capacity (yo-yo intermittent recovery test level 1 [YYIR1]), repeated sprint ability (7 x 35 m sprints) acceleration (15 m sprint) and four soccer skills tests (dribble with pass, dribbling speed, passing and shooting accuracy). Players' technical ability during match play was assessed in small-sided games of soccer (5 v 5) using a novel game technical scoring chart (scoring chart completed by coaches to assess technical performance in a match situation) developed from criteria (e.g., first touch, dribbling and two footedness) used by youth soccer coaches for talent identification. A Spearman's rank correlation showed the YYIR1 test and 15 m sprint test were limited in predicting technical match performance (r=0.03, P=0.88, r=-0.23, P=0.32 respectively). A Pearson product moment correlation showed that the repeated sprint test was also limited in predicting technical match performance (r=-0.34, P=0.14). A dribbling skill with a pass was found to be the best determinant of a player's technical ability in a match (r=-0.57, P=0.00). Talent identification and selection programs in Asian youth soccer should include a dribbling skill performed with a pass.
Custodio, Nilton; Montesinos, Rosa; Lira, David; Herrera-Perez, Eder; Bardales, Yadira; Valeriano-Lorenzo, Lucia
2017-01-01
There is limited evidence about the progression of cognitive performance during the post-stroke stage. To assess the evolution of cognitive performance in stroke patients without vascular cognitive impairment (VCI), patients with vascular mild cognitive impairment (MCI), and patients with vascular dementia (VD). A prospective cohort of stroke outpatients from two secondary medical centers in Lima, Peru was studied. We performed standardized evaluations at definitive diagnosis (baseline evaluation), and control follow-ups at 6 and 12 months, including a battery of short cognitive tests: Clinical Dementia Rating (CDR), Addenbrooke's Cognitive Examination (ACE), and INECO Frontal Screening (IFS). 152 outpatients completed the follow-up, showing progressive increase in mean score on the CDR(0.34 to 0.46), contrary to the pattern observed on the ACE and IFS (78.18 to 76.48 and 23.63 to 22.24). The box plot for the CDR test showed that VCI patients had progressive worsening (0.79 to 0.16). Conversely, this trend was not observed in subjects without VCI. The box plot for the ACE and IFS showed that, for the majority of the differentiated stroke types, both non-VCI and VCI patients had progressive worsening. According to both ACE and IFS results during a 1-year follow-up, the cognitive performance of stroke patients worsened, a trend which was particularly consistent in infarction-type stroke patients.
Comparison of different soft grippers for lunch box packaging.
Wang, Zhongkui; Zhu, Mingzhu; Kawamura, Sadao; Hirai, Shinichi
2017-01-01
Automating the lunch box packaging is a challenging task due to the high deformability and large individual differences in shape and physical property of food materials. Soft robotic grippers showed potentials to perform such tasks. In this paper, we presented four pneumatic soft actuators made of different materials and different fabrication methods and compared their performances through a series of tests. We found that the actuators fabricated by 3D printing showed better linearity and less individual differences, but showed low durability compared to actuators fabricated by traditional casting process. Robotic grippers were assembled using the soft actuators, and grasping tests were performed on soft paper containers filled with food materials. Results suggested that grippers with softer actuators required lower air pressure to lift up the same weight and generated less deformation on the soft container. The actuator made of casting process with Dragon Skin 10 material lifted the most weight among different actuators.
Glenn A. Cooper
1967-01-01
A 6-year exposure test of three styles of siding made from nine hardwoods and given three treatments showed that full-length yellow-poplar vertical tongue-and-groove siding dip-treated in a water-repellent preservative performed best.
Spatial ability mediates the gender difference in middle school students' science performance.
Ganley, Colleen M; Vasilyeva, Marina; Dulaney, Alana
2014-01-01
Prior research has demonstrated a male advantage in spatial skills and science achievement. The present research integrated these findings by testing the potential role of spatial skills in gender differences in the science performance of eighth-grade students (13-15 years old). In (N = 113), the findings showed that mental rotation ability mediated gender differences in physical science and technology/engineering test scores. In (N = 73,245), science performance was examined in a state population of eighth-grade students. As in , the results revealed larger gender differences on items that showed higher correlations with mental rotation. These findings underscore the importance of considering spatial training interventions aimed at reducing gender differences in the science performance of school-aged children. © 2014 The Authors. Child Development © 2014 Society for Research in Child Development, Inc.
Calculating inspector probability of detection using performance demonstration program pass rates
NASA Astrophysics Data System (ADS)
Cumblidge, Stephen; D'Agostino, Amy
2016-02-01
The United States Nuclear Regulatory Commission (NRC) staff has been working since the 1970's to ensure that nondestructive testing performed on nuclear power plants in the United States will provide reasonable assurance of structural integrity of the nuclear power plant components. One tool used by the NRC has been the development and implementation of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code Section XI Appendix VIII[1] (Appendix VIII) blind testing requirements for ultrasonic procedures, equipment, and personnel. Some concerns have been raised, over the years, by the relatively low pass rates for the Appendix VIII qualification testing. The NRC staff has applied statistical tools and simulations to determine the expected probability of detection (POD) for ultrasonic examinations under ideal conditions based on the pass rates for the Appendix VIII qualification tests for the ultrasonic testing personnel. This work was primarily performed to answer three questions. First, given a test design and pass rate, what is the expected overall POD for inspectors? Second, can we calculate the probability of detection for flaws of different sizes using this information? Finally, if a previously qualified inspector fails a requalification test, does this call their earlier inspections into question? The calculations have shown that one can expect good performance from inspectors who have passed appendix VIII testing in a laboratory-like environment, and the requalification pass rates show that the inspectors have maintained their skills between tests. While these calculations showed that the PODs for the ultrasonic inspections are very good under laboratory conditions, the field inspections are conducted in a very different environment. The NRC staff has initiated a project to systematically analyze the human factors differences between qualification testing and field examinations. This work will be used to evaluate and prioritize potential human factors issues that may degrade performance in the field.
NASA Astrophysics Data System (ADS)
Purnomo, A.; Widyawan; Najib, W.; Hartono, R.; Hartatik
2018-03-01
Mobile adhoc network (MANET) consists of nodes that are independent. A node can communicate each other without the presence of network infrastructure. A node can act as a transmitter and receiver as well as a router. This research has been variation in active route timeout and my route timeout on the performance of AODV-ETX protocol in MANET. The AODV-ETX protocol is the AODV protocol that uses the ETX metric. Performance testing is done on the static node topology with 5 m x 5 m node grid model where the distance between nodes is 100 m and node topology that consists of 25 nodes moves randomly with a moving speed of 1.38 m/s in an area of 1500 m x 300 m. From the test result, on the static node, AODV protocol-ETX shows optimal performance at a value MRT and ART of 10 s and 15 s, but showed a stable performance in the value of MRT and ART ≥60 s, while in randomly moved node topology shows stable performance in the value of MRT and ART ≥80 s.
NASA Technical Reports Server (NTRS)
Jordan, J. L.; Platz, S. J.; Schinstock, W. C.
1986-01-01
Flight test results are presented documenting the effect of airframe icing on performance and stability and control of a NASA DHC-6 icing research aircraft. Kohlman System Research, Inc., provided the data acquisition system and data analysis under contract to NASA. Performance modeling methods and MMLE techniques were used to determine the effects of natural ice on the aircraft. Results showed that ice had a significant effect on the drag coefficient of the aircraft and a modest effect on the MMLE derived longitudinal stability coefficients (code version MMLE). Data is also presented on asymmetric power sign slip maneuvers showing rudder floating characteristics with and without ice on the vertical stabilizer.
Mhenni, Thouraya; Michalsik, Lars Bojsen; Mejri, Mohamed Arbi; Yousfi, Narimen; Chaouachi, Anis; Souissi, Nizar; Chamari, Karim
2017-05-01
This study investigated the two different time-of-day effect on team-handball-related short-term maximal physical performances. At two different time-of-day, fifteen young female team handball players performed different physical tests: HandGrip (HG) test, Ball-Throwing Velocity (BTV) test, Modified Agility T-test (MAT) and Repeated Shuttle-Sprint and Jump Ability (RSSJA) test. Rating of perceived exertion (RPE) scale was determined following the termination of the last test. Measurements were performed at two separate testing sessions (i.e., in the morning (7:00-8:30 h) and in the early evening (17:00-18:30 h)) in a randomised and counter-balanced setting on non-consecutive days. The results showed that HG (P = 0.0013), BTV (P = 0.0027) and MAT (P < 0.001) performances were better in the evening compared with the morning. During RSSJA, both best and mean sprint times were shorter in the evening compared to the morning (P < 0.001). Moreover, during the latter test, mean jump performance was higher in the evening compared to the morning (P = 0.026). However, there was no morning-evening difference in the best jump performance during RSSJA. Likewise, jump performance decrement was not affected by the time-of-day of testing. On the other hand, RPE fluctuated, with morning nadirs and afternoon/early evening highest values. The findings suggest that in female team handball players, team-handball-related short-term maximal physical performances were better in the afternoon than in the morning.
Performance indicators and decision making for outsourcing public health laboratory services.
Santos, Maria Angelica Borges dos; Moraes, Ricardo Montes de; Passos, Sonia Regina Lambert
2012-06-01
To develop performance indicators for outsourcing clinical laboratory services, based on information systems and public administrative records. In the municipality of Rio de Janeiro, Southern Brazil, the public health laboratory network comprised 33 laboratories with automated equipment (but no integrated information system), 90 primary care units (where sample collection was performed) and 983 employees. Information records were obtained from the administrative records of the Budget Information System for Public Health and the Outpatient and Hospital Information System of the Unified Health System. Performance indicators (production, productivity, usage and costs) were generated from data collected routinely from 2006 to 2008. The variations in production, costs and unit prices for tests were analyzed by Laspeyres and Paasche indices, which specifically measure laboratory activity, and by the Consumer Price Index from the Brazilian Institute of Geography and Statistics. A total of 10,359,111 tests were performed in 2008 (10.6% increase over 2006), and the test/employee ratio grew by 8.6%. The costs of supplies, wages and providers increased by 2.3%, 45.4% and 18.3%, respectively. The laboratory tests per visit and hospitalizations increased by 10% and 20%, respectively. The direct costs totaled R$ 63.2 million in 2008, representing an increase of 22.2% in current values during the period analyzed. The direct costs deflated by the Brazilian National Consumer Price Index (9.5% for the period) showed an 11.6% increase in production volumes. The activity-specific volume index, which considers changes in the mix of tests, showed increases of 18.5% in the test price and 3.1% in the production volume. The performance indicators, particularly the specific indices for volume and price of activity, constitute a baseline of performance potential for monitoring private laboratories and contractors. The economic performance indicators demonstrated the need for network information system integration prior to an outsourcing decision.
Accounting for estimated IQ in neuropsychological test performance with regression-based techniques.
Testa, S Marc; Winicki, Jessica M; Pearlson, Godfrey D; Gordon, Barry; Schretlen, David J
2009-11-01
Regression-based normative techniques account for variability in test performance associated with multiple predictor variables and generate expected scores based on algebraic equations. Using this approach, we show that estimated IQ, based on oral word reading, accounts for 1-9% of the variability beyond that explained by individual differences in age, sex, race, and years of education for most cognitive measures. These results confirm that adding estimated "premorbid" IQ to demographic predictors in multiple regression models can incrementally improve the accuracy with which regression-based norms (RBNs) benchmark expected neuropsychological test performance in healthy adults. It remains to be seen whether the incremental variance in test performance explained by estimated "premorbid" IQ translates to improved diagnostic accuracy in patient samples. We describe these methods, and illustrate the step-by-step application of RBNs with two cases. We also discuss the rationale, assumptions, and caveats of this approach. More broadly, we note that adjusting test scores for age and other characteristics might actually decrease the accuracy with which test performance predicts absolute criteria, such as the ability to drive or live independently.
Mainz, Nina; Shao, Zeshu; Brysbaert, Marc; Meyer, Antje S.
2017-01-01
Vocabulary knowledge is central to a speaker's command of their language. In previous research, greater vocabulary knowledge has been associated with advantages in language processing. In this study, we examined the relationship between individual differences in vocabulary and language processing performance more closely by (i) using a battery of vocabulary tests instead of just one test, and (ii) testing not only university students (Experiment 1) but young adults from a broader range of educational backgrounds (Experiment 2). Five vocabulary tests were developed, including multiple-choice and open antonym and synonym tests and a definition test, and administered together with two established measures of vocabulary. Language processing performance was measured using a lexical decision task. In Experiment 1, vocabulary and word frequency were found to predict word recognition speed while we did not observe an interaction between the effects. In Experiment 2, word recognition performance was predicted by word frequency and the interaction between word frequency and vocabulary, with high-vocabulary individuals showing smaller frequency effects. While overall the individual vocabulary tests were correlated and showed similar relationships with language processing as compared to a composite measure of all tests, they appeared to share less variance in Experiment 2 than in Experiment 1. Implications of our findings concerning the assessment of vocabulary size in individual differences studies and the investigation of individuals from more varied backgrounds are discussed. PMID:28751871
RP-2 Thermal Stability and Heat Transfer Investigation for Hydrocarbon Boost Engines
NASA Technical Reports Server (NTRS)
VanNoord, J. L.; Stiegemeier, B. R.
2010-01-01
A series of electrically heated tube tests were performed at the NASA Glenn Research Center s Heated Tube Facility to investigate the use of RP-2 as a fuel for next generation regeneratively cooled hydrocarbon boost engines. The effect that test duration, operating condition and test piece material have on the overall thermal stability and materials compatibility characteristics of RP-2 were evaluated using copper and 304 stainless steel test sections. The copper tests were run at 1000 psia, heat flux up to 6.0 Btu/in.2-sec, and wall temperatures up to 1180 F. Preliminary results, using measured wall temperature as an indirect indicator of the carbon deposition process, show that in copper test pieces above approximately 850 F, RP-2 begins to undergo thermal decomposition resulting in local carbon deposits. Wall temperature traces show significant local temperature increases followed by near instantaneous drops which have been attributed to the carbon deposition/shedding process in previous investigations. Data reduction is currently underway for the stainless steel test sections and carbon deposition measurements will be performed in the future for all test sections used in this investigation. In conjunction with the existing thermal stability database, these findings give insight into the feasibility of cooling a long life, high performance, high-pressure liquid rocket combustor and nozzle with RP-2.
Performance tests of a two phase ejector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harrell, G.S.; Kornhauser, A.A.
1995-12-31
The ejector expansion refrigeration cycle is a modified vapor compression cycle in which a two phase ejector is used to recover a portion of the work otherwise lost in the expansion valve. The ejector improves cycle performance by increasing compressor inlet pressure and by lowering the quality of liquid entering the evaporator. Theoretically, a cooling COP improvement of approximately 23% is achievable for a typical refrigerating cycle and an ideal ejector. If the ejector performed as well as typical single phase ejectors an improvement of 12% could be achieved. Previous tests have demonstrated a smaller 3.7% improvement; the difference ismore » in the poor performance of the two phase ejector. The purpose of this research is to understand the operating characteristics of the two phase ejector and to devise design improvements. A two phase ejector test rig has been constructed and tested. Preliminary data show performance superior to previously tested two phase ejectors, but still inferior to single phase ejectors. Ejector performance corresponds to refrigeration cycle COP improvements ranging from 3.9% to 7.6%.« less
Trait impulsivity predicts D-KEFS tower test performance in university students.
Lyvers, Michael; Basch, Vanessa; Duff, Helen; Edwards, Mark S
2015-01-01
The present study examined a widely used self-report index of trait impulsiveness in relation to performance on a well-known neuropsychological executive function test in 70 university undergraduate students (50 women, 20 men) aged 18 to 24 years old. Participants completed the Barratt Impulsiveness Scale (BIS-11) and the Frontal Systems Behavior Scale (FrSBe), after which they performed the Tower Test of the Delis-Kaplan Executive Function System. Hierarchical linear regression showed that after controlling for gender, current alcohol consumption, age at onset of weekly alcohol use, and FrSBe scores, BIS-11 significantly predicted Tower Test Achievement scores, β = -.44, p < .01. The results indicate that self-reported impulsiveness is associated with poorer executive cognitive performance even in a sample likely to be characterized by relatively high general cognitive functioning (i.e., university students). The results also support the role of inhibition as a key aspect of executive task performance. Elevated scores on the BIS-11 and FrSBe are known to be linked to risky drinking in young adults as confirmed in this sample; however, only BIS-11 predicted Tower Test performance.
Ichise, M; Chung, D G; Wang, P; Wortzman, G; Gray, B G; Franks, W
1994-02-01
The purposes of this study were: (1) to compare 99mTc-hexamethylpropyleneamineoxime (HMPAO) SPECT with CT and MRI in chronic traumatic brain injury (TBI) patients and (2) to correlate both functional and structural neuroimaging measurements of brain damage with neuropsychological (NP) performance. Twenty-nine patients (minor TBI, n = 15 and major TBI, n = 14) and 17 normal controls (NC) underwent HMPAO SPECT, CT, MRI and NP testing. Imaging data were analyzed both visually and quantitatively. Nineteen (66%) patients showed 42 abnormalities on SPECT images, whereas 13 (45%) and 10 (34%) patients showed 29 abnormalities on MRI and 24 abnormalities on CT. SPECT detected relatively more abnormalities than CT or MRI in the minor TBI subgroup. The TBI group showed impairment on 11 tests for memory, attention and executive function. Of these, the anterior-posterior ratio (APR) correlated with six tests, whereas the ventricle-to-brain ratio (VBR), a known structural index of a poor NP outcome, correlated with only two tests. In evaluating chronic TBI patients, HMPAO SPECT, as a complement to CT or MRI, may play a useful role by demonstrating brain dysfunction in morphologically intact brain regions and providing objective evidence for some of the impaired NP performance.
Biological activity studies of the novel glucagon-like peptide-1 derivative HJ07.
Han, Jing; Sun, Li-Dan; Qian, Hai; Huang, Wen-Long
2014-08-01
To identify the glucose lowering ability and chronic treatment effects of a novel coumarin-glucagon-like peptide-1 (GLP-1) conjugate HJ07. A receptor activation experiment was performed in HEK 293 cells and the glucose lowering ability was evaluated with hypoglycemic duration and glucose stabilizing tests. Chronic treatment was performed by daily injection of exendin-4, saline, and HJ07. Body weight and HbA1c were measured every week, and an intraperitoneal glucose tolerance test was performed before treatment and after treatment. HJ07 showed well-preserved receptor activation efficacy. The hypoglycemic duration test showed that HJ07 possessed a long-acting, glucose-lowering effect and the glucose stabilizing test showed that the antihyperglycemic activity of HJ07 was still evident at a predetermined time (12 h) prior to the glucose challenge (0 h). The long time glucose-lowering effect of HJ07 was better than native GLP-1 and exendin-4. Furthermore, once daily injection of HJ07 to db/db mice achieved long-term beneficial effects on HbA1c lowering and glucose tolerance. The biological activity results of HJ07 suggest that HJ07 is a potential long-acting agent for the treatment of type 2 diabetes. Copyright © 2014 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.
Pizza, Fabio; Contardi, Sara; Mondini, Susanna; Trentin, Lino; Cirignotta, Fabio
2009-01-01
Study Objectives: To test the reliability of a driving-simulation test for the objective measurement of daytime alertness compared with the Multiple Sleep Latency Test (MSLT) and with the Maintenance of Wakefulness Test (MWT), and to test the ability to drive safely, in comparison with on-road history, in the clinical setting of untreated severe obstructive sleep apnea. Design: N/A. Setting: Sleep laboratory. Patients or Participants: Twenty-four patients with severe obstructive sleep apnea and reported daytime sleepiness varying in severity (as measured by the Epworth Sleepiness Scale). Interventions: N/A. Measurements and Results: Patients underwent MSLT and MWT coupled with 4 sessions of driving-simulation test on 2 different days randomly distributed 1 week apart. Simulated-driving performance (in terms of lane-position variability and crash occurrence) was correlated with sleep latency on the MSLT and more significantly on the MWT, showing a predictive validity toward the detection of sleepy versus alert patients with obstructive sleep apnea. In addition, patients reporting excessive daytime sleepiness or a history of car crashes showed poorer performances on the driving simulator. Conclusions: A simulated driving test is a suitable tool for objective measurement of daytime alertness in patients with obstructive sleep apnea. Further studies are needed to clarify the association between simulated-driving performance and on-road crash risk of patients with sleep disordered breathing. Citation: Pizza F; Contardi S; Mondini S; Trentin L; Cirignotta F. Daytime sleepiness and driving performance in patients with obstructive sleep apnea: comparison of the MSLT, the MWT, and a simulated driving task. SLEEP 2009;32(3):382-391. PMID:19294958
Stafylis, Chrysovalantis; Klausner, Jeffrey D
2017-01-01
Fourth generation assays detect simultaneously antibodies for HIV and the p24 antigen, identifying HIV infection earlier than previous generation tests. Previous studies have shown that the Alere Determine HIV-1/2 Combo has lower than anticipated performance in detecting antibodies for HIV and the p24 antigen. Furthermore, there are currently very few studies evaluating the performance of Standard Diagnostics BIOLINE HIV Ag/Ab Combo. To evaluate the performance of the Alere Determine HIV-1/2 Combo and the Standard Diagnostics BIOLINE HIV Ag/Ab Combo in a panel of frozen serum samples. The testing panel included 133 previously frozen serum specimens from the UCLA Clinical Microbiology & Immunoserology laboratory. Reference testing included testing for HIV antibodies by a 3rd generation enzyme immunoassay followed by HIV RNA detection. Antibody negative and RNA positive sera were also tested by a laboratory 4th generation HIV Ab/Ag enzyme immunoassay. Reference testing yielded 97 positives for HIV infection and 36 negative samples. Sensitivity of the Alere test was 95% (88-98%), while the SD Bioline sensitivity was 91% (83-96%). Both assays showed 100% (90-100%) specificity. No indeterminate or invalid results were recorded. Among 13 samples with acute infection (HIV RNA positive, HIV antibody negative), 12 were found positive by the first assay and 8 by the second. The antigen component of the Alere assay detected 10 acute samples, while the SD Bioline assay detected only one. Both rapid assays showed very good overall performance in detecting HIV infection in frozen serum samples, but further improvements are required to improve the performance in acute infection.
Parikh, Mili; Hynan, Linda S; Weiner, Myron F; Lacritz, Laura; Ringe, Wendy; Cullum, C Munro
2014-01-01
Alzheimer disease (AD) characteristically begins with episodic memory impairment followed by other cognitive deficits; however, the course of illness varies, with substantial differences in the rate of cognitive decline. For research and clinical purposes it would be useful to distinguish between persons who will progress slowly from persons who will progress at an average or faster rate. Our objective was to use neurocognitive performance features and disease-specific and health information to determine a predictive model for the rate of cognitive decline in participants with mild AD. We reviewed the records of a series of 96 consecutive participants with mild AD from 1995 to 2011 who had been administered selected neurocognitive tests and clinical measures. Based on Clinical Dementia Rating (CDR) of functional and cognitive decline over 2 years, participants were classified as Faster (n = 45) or Slower (n = 51) Progressors. Stepwise logistic regression analyses using neurocognitive performance features, disease-specific, health, and demographic variables were performed. Neuropsychological scores that distinguished Faster from Slower Progressors included Trail Making Test - A, Digit Symbol, and California Verbal Learning Test (CVLT) Total Learned and Primacy Recall. No disease-specific, health, or demographic variable predicted rate of progression; however, history of heart disease showed a trend. Among the neuropsychological variables, Trail Making Test - A best distinguished Faster from Slower Progressors, with an overall accuracy of 68%. In an omnibus model including neuropsychological, disease-specific, health, and demographic variables, only Trail Making Test - A distinguished between groups. Several neuropsychological performance features were associated with the rate of cognitive decline in mild AD, with baseline Trail Making Test - A performance best separating those who declined at an average or faster rate from those who showed slower progression.
Standing wave performance test of IDT-SAW transducer prepared by silk-screen printing
NASA Astrophysics Data System (ADS)
Wang, Ziping; Jiang, Zhengxuan; Chen, Liangbin; Li, Yefei; Li, Meixia; Wang, Shaohan
2018-05-01
With the advantages of high performance and low loss, interdigital surface acoustic wave (IDT-SAW) transducers are widely used in the fields of nondestructive testing, communication and broadcasting. The production, performance and application of surface acoustic wave (SAW) actuators has become a research hotspot. Based on the basic principle of SAW, an IDT-SAW transducer is designed and fabricated using silk-screen printing in this work. The experiment results show that in terms of SAW performance, the fabricated IDT-SAW transducer can generate standing wave fields comparable to those generated using traditional fabrication methods. The resonant frequency response of the IDT-SAW transducer and SAW attenuation coefficient were obtained by experiments. It has provided a method to test the transducer sensing performance by using fabricated IDT-SAW transducer.
The effect of phosphatidylserine on golf performance
Jäger, Ralf; Purpura, Martin; Geiss, Kurt-Reiner; Weiß, Michael; Baumeister, Jochen; Amatulli, Francesco; Schröder, Lars; Herwegen, Holger
2007-01-01
Background A randomized, double-blind, placebo-controlled study was performed to evaluate the effect of oral phosphatidylserine (PS) supplementation on golf performance in healthy young golfers with handicaps of 15–40. Methods Perceived stress, heart rate and the quality of the ball flight was evaluated before (pre-test) and after (post-test) 42 days of 200 mg per day PS (n = 10) or placebo (n = 10) intake in the form of a nutritional bar. Subjects teed-off 20 times aiming at a green 135 meters from the tee area. Results PS supplementation significantly increased (p < 0.05) the number of good ball flights (mean: pre-test 8.3 ± 3.5, post-test 10.1 ± 3.0), whereas placebo intake (mean: pre-test 7.8 ± 2.4, post-test 7.9 ± 3.6) had no effect. PS supplementation showed a trend towards improving perceived stress levels during teeing-off (mean: pre-test 5.8 ± 2.0, post-test 4.0 ± 2.0, p = 0.07), whereas stress levels remained unchanged in the placebo group (mean: pre-test: 5.1 ± 2.0, post-test: 5.1 ± 3.1). Supplementation did not influence mean heart rate in either group. Conclusion It is concluded that six weeks of PS supplementation shows a statistically not significant tendency (p = 0.07) to improve perceived stress levels in golfers and significantly improves (p < 0.05) the number of good ball flights during tee-off which might result in improved golf scores. PMID:18053194
Arad, Tschingis; Baumeister, Martin; Bühren, Jens; Kohnen, Thomas
2017-04-20
Automated measurements of reading performance are required for clinical trials involving presbyopia-correcting surgery options. Repeatability of a testing device for reading (Salzburg Reading Desk) was evaluated in a prepresbyopic population. Subjective reading performance of 50 subjects divided into 2 age groups (23-30 years and 38-49 years) with distance-corrected eyes was investigated with different log-scaled reading charts. At study entry, refractive parameters were measured and distance visual acuity assessed. Two standardized binocular measurements were performed for each subject (32.24 ± 9.87 days apart [mean ± SD]). The repeatability of the tests was estimated using correlation coefficients, Wilcoxon signed-rank test, and Bland-Altman method. The test parameters at both maximum reading rate (MRR) measurements demonstrate a strong relationship of age group 2 subjects (correlation coefficient [r] = 0.74 p = 10-4) and of younger subjects (age group 1: r = 0.69, p = 10-4). Prepresbyopic subjects of age group 2 showed moderate results for near reading distance (r = 0.67, p = 10-4); by contrast, younger subjects had poorer results (r = 0.55, p = 10-3). The Wilcoxon signed-rank test revealed agreement between measurements and Bland-Altman plots showed a wide data spread for MRR and near reading distance in both groups. The device measures repeatedly selected reading performance parameters of near real world conditions, such as MRR, in prepresbyopic populations if several factors are taken into account. The option to choose preferred distance leads to more variance in measuring repeated reading performance. German Clinical Trials Register (DRKS) registration reference number: DRKS00000784.
A rule-based software test data generator
NASA Technical Reports Server (NTRS)
Deason, William H.; Brown, David B.; Chang, Kai-Hsiung; Cross, James H., II
1991-01-01
Rule-based software test data generation is proposed as an alternative to either path/predicate analysis or random data generation. A prototype rule-based test data generator for Ada programs is constructed and compared to a random test data generator. Four Ada procedures are used in the comparison. Approximately 2000 rule-based test cases and 100,000 randomly generated test cases are automatically generated and executed. The success of the two methods is compared using standard coverage metrics. Simple statistical tests showing that even the primitive rule-based test data generation prototype is significantly better than random data generation are performed. This result demonstrates that rule-based test data generation is feasible and shows great promise in assisting test engineers, especially when the rule base is developed further.
Modeling Local Item Dependence Due to Common Test Format with a Multidimensional Rasch Model
ERIC Educational Resources Information Center
Baghaei, Purya; Aryadoust, Vahid
2015-01-01
Research shows that test method can exert a significant impact on test takers' performance and thereby contaminate test scores. We argue that common test method can exert the same effect as common stimuli and violate the conditional independence assumption of item response theory models because, in general, subsets of items which have a shared…
Bloemen, Manon A T; de Groot, Janke F; Backx, Frank J G; Westerveld, Rosalyne A; Takken, Tim
2015-05-01
To determine the best test performance and feasibility using a Graded Arm Cranking Test vs a Graded Wheelchair Propulsion Test in young people with spina bifida who use a wheelchair, and to determine the reliability of the best test. Validity and reliability study. Young people with spina bifida who use a wheelchair. Physiological responses were measured during a Graded Arm Cranking Test and a Graded Wheelchair Propulsion Test using a heart rate monitor and calibrated mobile gas analysis system (Cortex Metamax). For validity, peak oxygen uptake (VO2peak) and peak heart rate (HRpeak) were compared using paired t-tests. For reliability, the intra-class correlation coefficients, standard error of measurement, and standard detectable change were calculated. VO2peak and HRpeak were higher during wheelchair propulsion compared with arm cranking (23.1 vs 19.5 ml/kg/min, p = 0.11; 165 vs 150 beats/min, p < 0.05). Reliability of wheelchair propulsion showed high intra-class correlation coefficients (ICCs) for both VO2peak (ICC = 0.93) and HRpeak (ICC = 0.90). This pilot study shows higher HRpeak and a tendency to higher VO2peak in young people with spina bifida who are using a wheelchair when tested during wheelchair propulsion compared with arm cranking. Wheelchair propulsion showed good reliability. We recommend performing a wheelchair propulsion test for aerobic fitness testing in this population.
CSI Flight Computer System and experimental test results
NASA Technical Reports Server (NTRS)
Sparks, Dean W., Jr.; Peri, F., Jr.; Schuler, P.
1993-01-01
This paper describes the CSI Computer System (CCS) and the experimental tests performed to validate its functionality. This system is comprised of two major components: the space flight qualified Excitation and Damping Subsystem (EDS) which performs controls calculations; and the Remote Interface Unit (RIU) which is used for data acquisition, transmission, and filtering. The flight-like RIU is the interface between the EDS and the sensors and actuators positioned on the particular structure under control. The EDS and RIU communicate over the MIL-STD-1553B, a space flight qualified bus. To test the CCS under realistic conditions, it was connected to the Phase-0 CSI Evolutionary Model (CEM) at NASA Langley Research Center. The following schematic shows how the CCS is connected to the CEM. Various tests were performed which validated the ability of the system to perform control/structures experiments.
Test sensitivity is important for detecting variability in pointing comprehension in canines.
Pongrácz, Péter; Gácsi, Márta; Hegedüs, Dorottya; Péter, András; Miklósi, Adám
2013-09-01
Several articles have been recently published on dogs' (Canis familiaris) performance in two-way object choice experiments in which subjects had to find hidden food by utilizing human pointing. The interpretation of results has led to a vivid theoretical debate about the cognitive background of human gestural signal understanding in dogs, despite the fact that many important details of the testing method have not yet been standardized. We report three experiments that aim to reveal how some procedural differences influence adult companion dogs' performance in these tests. Utilizing a large sample in Experiment 1, we provide evidence that neither the keeping conditions (garden/house) nor the location of the testing (outdoor/indoor) affect a dogs' performance. In Experiment 2, we compare dogs' performance using three different types of pointing gestures. Dogs' performance varied between momentary distal and momentary cross-pointing but "low" and "high" performer dogs chose uniformly better than chance level if they responded to sustained pointing gestures with reinforcement (food reward and a clicking sound; "clicker pointing"). In Experiment 3, we show that single features of the aforementioned "clicker pointing" method can slightly improve dogs' success rate if they were added one by one to the momentary distal pointing method. These results provide evidence that although companion dogs show a robust performance at different testing locations regardless of their keeping conditions, the exact execution of the human gesture and additional reinforcement techniques have substantial effect on the outcomes. Consequently, researchers should standardize their methodology before engaging in debates on the comparative aspects of socio-cognitive skills because the procedures they utilize may differ in sensitivity for detecting differences.
The Effects of Group Interdependence on Supervisor Performance Evaluations.
ERIC Educational Resources Information Center
Liden, Robert C.; Mitchell, Terence R.
1983-01-01
Tested the effect of group member interdependence on supervisory performance ratings. Students (N=72) played the role of supervisors in charge of evaluating members of a three-person work group. Results showed supervisors rated the poor performer higher and the good performers lower when the group was portrayed as highly interdependent. (JAC)
Physiological behavior of bean's seeds and grains during storage.
Cassol, Flávia D R; Fortes, Andréa M T; Mendonça, Lorena C; Buturi, Camila V; Marcon, Thaís R
2016-05-31
Beans are one of the most used foods to meet the energy needs of the Brazilian diet, requiring farmers to use high seed physiological potential. The aim was to evaluate the physiological quality of beans stored for 360 days. Analyses were performed at 0, 30, 90, 180, 270, and 360 days after receiving the seeds (S1 and S2) and grains (G1 and G2) of BRS Splendor. Tests of germination, accelerated aging, cold, speed of germination, average length of shoots, and root were performed. The experimental design was completely randomized split-plot in time and the means were compared through Tukey test at 5% probability. Seed germination was not affected in S2, while the drop in S1 and G1 was significant. The vigor of grains from field 1 declined from 91 to 50% and from 93% to 76% by accelerated aging and cold, respectively, after 360 days. The germination speed tests performed showed a decreased during the experiment. The grains from field 1 had lower physiological quality. The accelerated aging and cold tests, through the speed of germination parameter, showed decrease in the vigor of the Splendor BRS. The storage period influenced the physiological quality of the beans tested.
A Study of relationship between frailty and physical performance in elderly women.
Jeoung, Bog Ja; Lee, Yang Chool
2015-08-01
Frailty is a disorder of multiple inter-related physiological systems. It is unclear whether the level of physical performance factors can serve as markers of frailty and a sign. The purpose of this study was to examine the relationship between frailty and physical performance in elderly women. One hundred fourteen elderly women participated in this study, their aged was from 65 to 80. We were measured 6-min walk test, grip-strength, 30-sec arm curl test, 30-sec chair stand test, 8 foot Up- and Go, Back scratch, chair sit and reach, unipedal stance, BMI, and the frailty with questionnaire. The collected data were analyzed by descriptive statistics, frequencies, correlation analysis, ANOVA, and simple liner regression using the IBM 21. SPSS program. In results, statistic tests showed that there were significant differences between frailty and 6-min walk test, 30-sec arm curl test, 30-sec chair stand test, grip-strength, Back scratch, and BMI. However, we did not find significant differences between frailty and 8 foot Up- and Go, unipedal stance. When the subjects were divided into five groups according to physical performance level, subjects with high 6-min walk, 30-sec arm curl test, chair sit and reach test, and high grip strength had low score frailty. Physical performance factors were strongly associated with decreased frailty, suggesting that physical performance improvements play an important role in preventing or reducing the frailty.
Jarrold, Christopher; Baddeley, Alan D; Phillips, Caroline
2007-02-01
Previous studies have suggested that Williams syndrome and Down syndrome may be associated with specific short-term memory deficits. Individuals with Williams syndrome perform relatively poorly on tests of visuo-spatial short-term memory and individuals with Down syndrome show a relative deficit on verbal short-term memory tasks. However, these patterns of impairments may reflect the impact of generally impaired visuo-spatial processing skills in Williams syndrome, and verbal abilities in Down syndrome. The current study explored this possibility by assessing long-term memory among 15 individuals with Williams syndrome and 20 individuals with Down syndrome using the Doors and People test, a battery which assesses recall and recognition of verbal and visual information. Individuals' performance was standardised for age and level of intellectual ability with reference to that shown by a sample of 110 typically developing children. The results showed that individuals with Down syndrome have no differential deficits in long-term memory for verbal information, implying that verbal short-term memory deficits in this population are relatively selective. Instead both individuals with Down syndrome and with Williams syndrome showed some evidence of relatively poor performance on tests of long-term memory for visual information. It is therefore possible that visuo-spatial short-term memory deficits that have previously been demonstrated in Williams syndrome may be secondary to more general problems in visuo-spatial processing in this population.
Multi-Fidelity Framework for Modeling Combustion Instability
2016-07-27
generated from the reduced-domain dataset. Evaluations of the framework are performed based on simplified test problems for a model rocket combustor showing...generated from the reduced-domain dataset. Evaluations of the framework are performed based on simplified test problems for a model rocket combustor...of Aeronautics and Astronautics and Associate Fellow AIAA. ‡ Professor Emeritus. § Senior Scientist, Rocket Propulsion Division and Senior Member
Woods, David L.; Wyma, John M.; Herron, Timothy J.; Yund, E. William
2017-01-01
Verbal learning tests (VLTs) are widely used to evaluate memory deficits in neuropsychiatric and developmental disorders. However, their validity has been called into question by studies showing significant differences in VLT scores obtained by different examiners. Here we describe the computerized Bay Area Verbal Learning Test (BAVLT), which minimizes inter-examiner differences by incorporating digital list presentation and automated scoring. In the 10-min BAVLT, a 12-word list is presented on three acquisition trials, followed by a distractor list, immediate recall of the first list, and, after a 30-min delay, delayed recall and recognition. In Experiment 1, we analyzed the performance of 195 participants ranging in age from 18 to 82 years. Acquisition trials showed strong primacy and recency effects, with scores improving over repetitions, particularly for mid-list words. Inter-word intervals (IWIs) increased with successive words recalled. Omnibus scores (summed over all trials except recognition) were influenced by age, education, and sex (women outperformed men). In Experiment 2, we examined BAVLT test-retest reliability in 29 participants tested with different word lists at weekly intervals. High intraclass correlation coefficients were seen for omnibus and acquisition scores, IWIs, and a categorization index reflecting semantic reorganization. Experiment 3 examined the performance of Experiment 2 participants when feigning symptoms of traumatic brain injury. Although 37% of simulated malingerers showed abnormal (p < 0.05) omnibus z-scores, z-score cutoffs were ineffective in discriminating abnormal malingerers from control participants with abnormal scores. In contrast, four malingering indices (recognition scores, primacy/recency effects, learning rate across acquisition trials, and IWIs) discriminated the two groups with 80% sensitivity and 80% specificity. Experiment 4 examined the performance of a small group of patients with mild or severe TBI. Overall, both patient groups performed within the normal range, although significant performance deficits were seen in some patients. The BAVLT improves the speed and replicability of verbal learning assessments while providing comprehensive measures of retrieval timing, semantic organization, and primacy/recency effects that clarify the nature of performance. PMID:28127280
Migraine patients consistently show abnormal vestibular bedside tests.
Maranhão, Eliana Teixeira; Maranhão-Filho, Péricles; Luiz, Ronir Raggio; Vincent, Maurice Borges
2016-01-01
Migraine and vertigo are common disorders, with lifetime prevalences of 16% and 7% respectively, and co-morbidity around 3.2%. Vestibular syndromes and dizziness occur more frequently in migraine patients. We investigated bedside clinical signs indicative of vestibular dysfunction in migraineurs. To test the hypothesis that vestibulo-ocular reflex, vestibulo-spinal reflex and fall risk (FR) responses as measured by 14 bedside tests are abnormal in migraineurs without vertigo, as compared with controls. Cross-sectional study including sixty individuals - thirty migraineurs, 25 women, 19-60 y-o; and 30 gender/age healthy paired controls. Migraineurs showed a tendency to perform worse in almost all tests, albeit only the Romberg tandem test was statistically different from controls. A combination of four abnormal tests better discriminated the two groups (93.3% specificity). Migraine patients consistently showed abnormal vestibular bedside tests when compared with controls.
The relation between knee muscle strength and performance tests in orienteering athletes.
Çinar-Medeni, Özge; Colakoglu, Fatma F; Yüce, Koray; Ipekoğlu, Gökhan; Baltaci, Gul
2016-11-01
The aim of this study was to analyze the effect of knee muscle strength on performance tests in orienteers. Thirty-seven orienteers were voluntarily included in this study. Isokinetic knee flexor and extensor muscles' strength was assessed at 120°/s velocity for both "dominant leg" (DL) and "non-dominant leg" (NDL). "Single-legged hop test" (SLHT), "flamingo balance test" (FBT), "star excursion balance test" (SEBT), vertical jump-and-reach test (for anaerobic power), T-drill test and 20-meter shuttle run test (for aerobic power) were carried out. Correlation and regression analyses were performed on the data. VO2max levels showed moderate correlations with DL's "flexor peak torque" (FPT) and NDL's "extensor peak torque" (EPT) and FPT values respectively (r=0.49, r=0.38, r=0.58). FPT of NDL was a predictor of VO2max level (R2=0.33). Anaerobic power has a relationship with EPT of NDL (r=0.43) and T-drill test with EPT and FPT values of both DL and NDL respectively (r=-0.35, r=-0.63, r=-0.53, r=-0.58). EPT of NDL was a predictor for anaerobic power (R2=0.19) and FPT of DL for agility (R2=0.40). Nonparametric linear regression results showed that EPT is a predictor in DL (median slope=-0.71, P=0.01), and FPT in NDL (median slope=-0.90, P=0.006) for FBT. FPT was a predictor of SEBT scores for both legs (0.13
Impact of Steel Fiber Size and Shape on the Mechanical Properties of Ultra-High Performance Concrete
2015-08-01
32 Appendix B: DTT Specimens Pretest / Posttest ..................................................................................... 36 Appendix C...type and then subsequently compared to that material’s UCS. Figure 6 shows the splitting tensile testing set-up, both pretest and posttest . Figure...9 show the actual test configuration, pretest and posttest , respectively. This configuration utilized a chucking mechanism suited to the shape of
Schwartz, Sarah M; Evans, Cathy; Agur, Anne M R
2015-01-01
Students in health care professional programs face many stressful tests that determine successful completion of their program. Test anxiety during these high stakes examinations can affect working memory and lead to poor outcomes. Methods of decreasing test anxiety include lengthening the time available to complete examinations or evaluating students using untimed examinations. There is currently no consensus in the literature regarding whether untimed examinations provide a benefit to test performance in clinical anatomy. This study aimed to determine the impact of timed versus untimed practical tests on Master of Physical Therapy student anatomy performance and test anxiety. Test anxiety was measured using the State-Trait Anxiety Inventory (STAI). Differences in performance, anxiety scores, and time taken were compared using paired sample Student's t-tests. Eighty-one of the 84 students completed the study and provided feedback. Students performed significantly higher on the untimed test (P = 0.005), with a significant reduction in test anxiety (P < 0.001). Students who were unsuccessful on the timed test showed the greatest improvement on the untimed test ( x¯ = 20.4 ±10%). Eighty-three percent (n = 69) of students preferred the untimed test, 8.4% (n = 7) the timed test, and 8.4% (n = 7) had no preference. Students took on average eight minutes longer on the untimed test. This study found that physical therapy students perform better on untimed tests, which may be related to a reduction in test anxiety. If the intended goal of evaluating health care professional students is to determine fundamental competencies, these factors should be considered when designing future curricula. © 2014 American Association of Anatomists.
Study of a heat rejection system for the Nuclear Electric Propulsion (NEP) spacecraft
NASA Technical Reports Server (NTRS)
Ernest, D. M.
1982-01-01
Two different heat pipe radiator elements, one intended for use with the power conversion subsystem of the NASA funded nuclear electric propulsion (NEP) spacecraft, and one intended for use with the DOE funded space power advanced reactor (SPAR) system were tested and evaluated. The NEP stainless steel/sodium heat pipe was 4.42 meters long and had a 1 cm diameter. Thermal performance testing at 920 K showed a non-limited power level of 3560 watts, well in excess of the design power of 2600 watts. This test verified the applicability of screen arteries for use in long radiator heat pipes. The SPAR titanium/potassium heat pipe was 5.5 meters long and had a semicircular crossection with a 4 cm diameter. Thermal performance testing at 775 K showed a maximum power level of 1.86 kW, somewhat short of the desired 2.6 kW beginning of life design requirement. The reduced performance was shown to be the result of the inability of the evaporator wall wick (shot blasted evaporator wall) to handle the required liquid flow.
Processing and performance of self-healing materials
NASA Astrophysics Data System (ADS)
Tan, P. S.; Zhang, M. Q.; Bhattacharyya, D.
2009-08-01
Two self-healing methods were implemented into composite materials with self-healing capabilities, using hollow glass fibres (HGF) and microencapsulated epoxy resin with mercaptan as the hardener. For the HGF approach, two perpendicular layers of HGF were put into an E-glass/epoxy composite, and were filled with coloured epoxy resin and hardener. The HGF samples had a novel ball indentation test method done on them. The samples were analysed using micro-CT scanning, confocal microscopy and penetrant dye. Micro-CT and confocal microscopy produced limited success, but their viability was established. Penetrant dye images showed resin obstructing flow of dye through damage regions, suggesting infiltration of resin into cracks. Three-point bend tests showed that overall performance could be affected by the flaws arising from embedding HGF in the material. For the microcapsule approach, samples were prepared for novel double-torsion tests used to generate large cracks. The samples were compared with pure resin samples by analysing them using photoelastic imaging and scanning electron microscope (SEM) on crack surfaces. Photoelastic imaging established the consolidation of cracks while SEM showed a wide spread of microcapsules with their distribution being affected by gravity. Further double-torsion testing showed that healing recovered approximately 24% of material strength.
Perceptions and performance using computer-based testing: One institution's experience.
Bloom, Timothy J; Rich, Wesley D; Olson, Stephanie M; Adams, Michael L
2018-02-01
The purpose of this study was to evaluate student and faculty perceptions of the transition to a required computer-based testing format and to identify any impact of this transition on student exam performance. Separate questionnaires sent to students and faculty asked about perceptions of and problems with computer-based testing. Exam results from program-required courses for two years prior to and two years following the adoption of computer-based testing were compared to determine if this testing format impacted student performance. Responses to Likert-type questions about perceived ease of use showed no difference between students with one and three semesters experience with computer-based testing. Of 223 student-reported problems, 23% related to faculty training with the testing software. Students most commonly reported improved feedback (46% of responses) and ease of exam-taking (17% of responses) as benefits to computer-based testing. Faculty-reported difficulties were most commonly related to problems with student computers during an exam (38% of responses) while the most commonly identified benefit was collecting assessment data (32% of responses). Neither faculty nor students perceived an impact on exam performance due to computer-based testing. An analysis of exam grades confirmed there was no consistent performance difference between the paper and computer-based formats. Both faculty and students rapidly adapted to using computer-based testing. There was no evidence that switching to computer-based testing had any impact on student exam performance. Copyright © 2017 Elsevier Inc. All rights reserved.
Accelerated long-term forgetting in resected and seizure-free temporal lobe epilepsy patients.
Visser, M; Forn, C; Gómez-Ibáñez, A; Rosell-Negre, P; Villanueva, V; Ávila, C
2018-03-12
Episodic memory impairments caused by temporal lobe epilepsy (TLE) are well documented in the literature. Standard clinical episodic memory tests typically include a 30-min delayed recall test. However, in the past decade, it has become apparent that this standard test does not capture the full range of memory problems in TLE patients. Some patients perform well on a standard 30-min delayed recall test, but show Accelerated Long-term Forgetting (ALF) after 24 h. Although ALF has been investigated in patients with different types of epilepsy, current research on resected TLE patients is missing. In the present study, resected TLE patients were compared to a control group matched on initial learning. They showed normal performance on verbal recall after 30 min, but impairments became apparent after one week. Moreover, the significant interaction between participant group and memory test delay demonstrated that the patients indeed showed an acceleration in forgetting. Furthermore, ALF was present in both left and right resected TLE patients, which contradicts the presence of material-specific hemispheric differences in ALF. In addition, ALF was observed in seizure-free resected TLE patients, thereby demonstrating that this factor is not crucial for long-term memory deficits. The outcome shows that clinicians are likely to underestimate memory deficits in resected TLE patients and, therefore, advocates for the inclusion of ALF tests in standard clinical batteries for both pre- and post-surgery testing sessions. Copyright © 2018 Elsevier Ltd. All rights reserved.
Modal Test of Six-Meter Hypersonic Inflatable Aerodynamic Decelerator
NASA Technical Reports Server (NTRS)
Abraham, Nijo; Buehrle, Ralph; Templeton, Justin; Lindell, Mike; Hancock, Sean M.
2014-01-01
A modal test was performed on the six-meter Hypersonic Inflatable Aerodynamic Decelerator (HIAD) test article to gain a firm understanding of the dynamic characteristics of the unloaded structure within the low frequency range. The tests involved various configurations of the HIAD to understand the influence of the tri-torus, the varying pressure within the toroids and the influence of straps. The primary test was conducted utilizing an eletrodynamic shaker and the results were verified using a step relaxation technique. The analysis results show an increase in the structure's stiffness with respect to increasing pressure. The results also show the rise of coupled modes with the tri-torus configurations. During the testing activity, the attached straps exhibited a behavior that is similar to that described as fuzzy structures in the literature. Therefore extensive tests were also performed by utilizing foam to mitigate these effects as well as understand the modal parameters of these fuzzy sub structures. Results are being utilized to update the finite element model of the six-meter HIAD and to gain a better understanding of the modeling of complex inflatable structures.
Hot-Fire Testing of 5N and 22N HPGP Thrusters
NASA Technical Reports Server (NTRS)
Burnside, Christopher G.; Pedersen, Kevin W.; Pierce, Charles W.
2015-01-01
This hot-fire test continues NASA investigation of green propellant technologies for future missions. To show the potential for green propellants to replace some hydrazine systems in future spacecraft, NASA Marshall Space Flight Center (MSFC) is continuing to embark on hot-fire test campaigns with various green propellant blends.NASA completed hot-fire testing of 5N and 22N HPGP thrusters at the Marshall Space Flight Center’s Component Development Area altitude test stand in April 2015. Both thrusters are ground test articles and not flight ready units, but are representative of potential flight hardware with a known path towards flight application. The purpose of the 5N testing was to perform facility check-outs and generate a small set of data for comparison to ECAPS and Orbital ATK data sets. The 5N thruster performed as expected with thrust and propellant flow-rate data generated that are similar to previous testing at Orbital ATK. Immediately following the 5N testing, and using the same facility, the 22N testing was conducted on the same test stand with the purpose of demonstrating the 22N performance. The results of 22N testing indicate it performed as expected.The results of the hot-fire testing are presented in this paper and presentation.
Test results and description of a 1-kW free-piston Stirling engine with a dashpot load
NASA Technical Reports Server (NTRS)
Schreiber, J.
1983-01-01
A 1 kW (1.33 hp) single cylinder free piston Stirling engine was installed in the test facilities at the Lewis laboratory. The engine was designed specifically for research of the dynamics of its operation. A more complete description of the engine and its instrumentation is provided in a prior NASA paper TM-82999 by J. G. Schreiber. Initial tests at Lewis showed the power level and efficiency of the engine to be below design level. Tests were performed to help determine the specific problems in the engine causing the below design level performance. Modifications to engine hardware and to the facility where performed in an effort to bring the power output and efficiency to their design values. As finally configured the engine generated more than 1250 watts of output power at an engine efficiency greater than 32 percent. This report presents the tests performed to help determine the specific problems, the results if the problem was eliminated, the fix performed to the hardware, and the test results after the engine was tested. In cases where the fix did not cause the anticipated effects, a possible explanation is given.
Code of Federal Regulations, 2010 CFR
2010-01-01
... to verify the existence and reliability of such tests, bear directly on whether the firm acted... relevance to the latter two remedies is whether reasonable and representative tests were performed... fabrics or on reasonable and representative tests showing that the fabric covered by the guaranty or used...
Edmonds, Caroline J; Jeffes, Ben
2009-12-01
Little research has examined the effect of water consumption on cognition in children. We examined whether drinking water improves performance from baseline to test in twenty-three 6-7-year-old children. There were significant interactions between time of test and water group (water/no water), with improvements in the water group on thirst and happiness ratings, visual attention and visual search, but not visual memory or visuomotor performance. These results indicate that even under conditions of mild dehydration, not as a result of exercise, intentional water deprivation or heat exposure, children's cognitive performance can be improved by having a drink of water.
Temporary Thermocouple Attachment for Thermal/Vacuum Testing at Non-Extreme Temperatures
NASA Technical Reports Server (NTRS)
Ungar, Eugene K.; Wright, Sarah E.
2016-01-01
Post-test examination and data analysis that followed a two week long vacuum test showed that numerous self-stick thermocouples became detached from the test article. The thermocouples were reattached with thermally conductive epoxy and the test was repeated to obtain the required data. Because the thermocouple detachment resulted in significant expense and rework, it was decided to investigate the temporary attachment methods used around NASA and to perform a test to assess their efficacy. The present work describes the original test and the analysis that showed that the thermocouples had become detached, temporary thermocouple attachment methods assessed in the retest and in the thermocouple attachment test, and makes a recommendation for attachment methods for future tests.
NASA Technical Reports Server (NTRS)
Knott, P. R.; Blozy, J. T.; Staid, P. S.
1981-01-01
The results of model scale parametric static and wind tunnel aerodynamic performance tests on unsuppressed coannular plug nozzle configurations with inverted velocity profile are discussed. The nozzle configurations are high-radius-ratio coannular plug nozzles applicable to dual-stream exhaust systems typical of a variable cycle engine for Advanced Supersonic Transport application. In all, seven acoustic models and eight aerodynamic performance models were tested. The nozzle geometric variables included outer stream radius ratio, inner stream to outer stream ratio, and inner stream plug shape. When compared to a conical nozzle at the same specific thrust, the results of the static acoustic tests with the coannular nozzles showed noise reductions of up to 7 PNdB. Extensive data analysis showed that the overall acoustic results can be well correlated using the mixed stream velocity and the mixed stream density. Results also showed that suppression levels are geometry and flow regulation dependent with the outer stream radius ratio, inner stream-to-outer stream velocity ratio and inner stream velocity ratio and inner stream plug shape, as the primary suppression parameters. In addition, high-radius ratio coannular plug nozzles were found to yield shock associated noise level reductions relative to a conical nozzle. The wind tunnel aerodynamic tests showed that static and simulated flight thrust coefficient at typical takeoff conditions are quite good - up to 0.98 at static conditions and 0.974 at a takeoff Mach number of 0.36. At low inner stream flow conditions significant thrust loss was observed. Using an inner stream conical plug resulted in 1% to 2% higher performance levels than nozzle geometries using a bent inner plug.
New frontiers in sport training: genetics and artistic gymnastics.
Morucci, Gabriele; Punzi, Tiziana; Innocenti, Giovanni; Gulisano, Massimo; Ceroti, Marco; Pacini, Stefania
2014-02-01
The increasing understanding of the genetic influences in sport has prompted an association study between the athletic performances and the polymorphisms of the angiotensin-converting enzyme (ACE), the α-actinin-3 (ACTN3), and the vitamin D receptor genes. The details of these gene polymorphisms can provide useful information to improve and plan new modern training programs for elite athletes. Eighty Italian male high level gymnasts were trained and tested for gymnastic-specific exercises and tested in all the men's artistic gymnastic apparatus (floor, pommel horse, rings, vault, parallel bars, and horizontal bar), and then genotyped. The training parameters of volume, intensity, and density of each gymnast were periodically measured during the season in each apparatus from the tests performed, and the seasonal average values were calculated. Gene polymorphisms were determined by polymerase chain reaction restriction fragment length polymorphism assay and studied in association with the performance results. The performances of ACE II gymnasts were significantly lower than that of the ACE ID/DD gymnasts in the apparatus expressing power features, confirming the predisposition of these athletes toward power-oriented sport. Gymnasts with ACTN3 RR/RX genotypes did not show a predisposition to the power-oriented apparatus, having worse performances compared with that of the ACTN3 XX gymnasts. Similarly, gymnasts with ACE II + ACTN3 RR/RX combined genotypes showed lower performances in comparison with that of the other gymnasts. Vitamin D receptor polymorphisms showed no significant association with the athletic performances. Because ACE insertion/deletion (I/D) and ACTN3 R577X polymorphisms heavily affect the physical performance of elite male gymnasts, the Italian Gymnastic Federation trainers have started to customize the current high-level training programs.
Pahlke, Erin; Hyde, Janet Shibley; Allison, Carlie M
2014-07-01
Proponents of single-sex (SS) education believe that separating boys and girls, by classrooms or schools, increases students' achievement and academic interest. In this article, we use meta-analysis to analyze studies that have tested the effects on students of SS compared with coeducational (CE) schooling. We meta-analyzed data from 184 studies, representing the testing of 1.6 million students in Grades K-12 from 21 nations, for multiple outcomes (e.g., mathematics performance, mathematics attitudes, science performance, educational aspirations, self-concept, gender stereotyping). To address concerns about the quality of research designs, we categorized studies as uncontrolled (no controls for selection effects, no random assignment) or controlled (random assignment or controls for selection effects). Based on mixed-effects analyses, uncontrolled studies showed some modest advantages for single-sex schooling, for both girls and boys, for outcomes such as mathematics performance but not for science performance. Controlled studies, however, showed only trivial differences between students in SS versus CE, for mathematics performance (g = 0.10 for girls, 0.06 for boys) and science performance (g = 0.06 for girls, 0.04 for boys), and in some cases showed small differences favoring CE schooling (e.g., for girls' educational aspirations, g = -0.26). Separate analyses of U.S. studies yielded similar findings (e.g., for mathematics performance g = 0.14 for girls and 0.14 for boys). Results from the highest quality studies, then, do not support the view that SS schooling provides benefits compared with CE schooling. Claims that SS schooling is particularly effective for U.S. ethnic minority boys could not be tested due to the lack of controlled studies on this question. PsycINFO Database Record (c) 2014 APA, all rights reserved.
Is Critical Thinking a Mediator Variable of Student Performance in School?
ERIC Educational Resources Information Center
Walter, Christel; Walter, Paul
2018-01-01
The study explores the influences of critical thinking and interests on students' performance at school. The tested students attended German grammar schools ("Gymnasien"). Separate regression analyses showed the expected moderate positive influences of critical thinking and interests on school performance. But analyzed simultaneously,…
Day Time Gimballing A-1 Test Stand
NASA Technical Reports Server (NTRS)
1989-01-01
A close-up view of a Space Shuttle Main Engine during a daytime test at Stennis Space Center shows how the engine is gimbaled, or rotated, to evaluate the performance of its components under simulated flight conditions.
A performance comparison of two small rocket nozzles
NASA Technical Reports Server (NTRS)
Arrington, Lynn A.; Reed, Brian D.; Rivera, Angel, Jr.
1996-01-01
An experimental study was conducted on two small rockets (110 N thrust class) to directly compare a standard conical nozzle with a bell nozzle optimized for maximum thrust using the Rao method. In large rockets, with throat Reynolds numbers of greater than 1 x 10(exp 5), bell nozzles outperform conical nozzles. In rockets with throat Reynolds numbers below 1 x 10(exp 5), however, test results have been ambiguous. An experimental program was conducted to test two small nozzles at two different fuel film cooling percentages and three different chamber pressures. Test results showed that for the throat Reynolds number range from 2 x 10(exp 4) to 4 x 10(exp 4), the bell nozzle outperformed the conical nozzle. Thrust coefficients for the bell nozzle were approximately 4 to 12 percent higher than those obtained with the conical nozzle. As expected, testing showed that lowering the fuel film cooling increased performance for both nozzle types.
NASA Technical Reports Server (NTRS)
Coe, H. H.; Parker, R. J.; Scibbe, H. W.
1975-01-01
An experimental investigation was performed to determine the rolling element fatigue life of electron beam-welded hollow balls with a diameter ratio (o.d./i.d.) of 1.26 and to determine the operating characteristics of bearings using these hollow balls. Similar bearings with solid balls were also tested and the data compared. The bearings were operated at shaft speeds up to 28,000 rpm with a thrust load of 2200 N (500 lb). Ball failures during the bearing tests were due to flexure fatigue. The solid and hollow ball bearings tested showed little difference in outer race temperatures and indicated the same bearing torque. The 17.5-mm (0.6875-in.) diameter balls were also tested in the five-ball fatigue tester and showed no significant difference in life when compared with the life of a solid ball.
[Evaluation (assessment) of three tests for diagnosis of geohelmints in Colombia].
López, Myriam Consuelo; Moncada, Ligia Inés; Ariza-Araújo, Yoseth; Fernández-Niño, Julián Alfredo; Reyes, Patricia; Nicholls, Rubén Santiago
2013-01-01
Soil-transmitted helminth infections are considered a public health problem in developing countries. The diagnostic tests, both for individual parient diagnosis as for population studies should be evaluated in terms of validity and reliability. To compare the direct examination, the modified Ritchie-Frick method, a Kato-Katz designed by a Brazilian group and one designed by the WHO, for the diagnosis of soil-transmitted helminthes. A diagnostic test reliability study was performed. The same stool sample was analyzed by the same observer using four diagnostic tests. 204 samples were obtained, 194 of those fulfilled the inclusion criteria and were analyzed. The observers did not know the participants' identity neither the other tests results. For the analysis the Kato-Katz (WHO) was considered as the gold standard. For the reliability assessment percent agreement, positive percent agreement, Kappa statistic, and intraclass correlation were performed. The Brazilian Kato-Katz showed a good performance with high sensitivity and specificity for T. trichiura and Hookworm with values of 0.97 and 0.96 respectively, and a high specificity with mild sensitivity for A. lumbricoides (0.95 and 0.79) meanwhile the direct examination and the Ritche-Frick method showed a performance between mild and poor. The differences were higher for hookworm and Trichiuris trichiura than for Ascaris lumbricoides. The Brazilian Kato Katz test could be implemented, but further studies are needed to correlate its operative capacity with its feasibility, availability and cost.
Castelain, M; Birnbaum, J; Castelain, P Y; Ducombs, G; Grosshans, E; Jelen, G; Lacroix, M; Meynadier, J; Mougeolle, J M; Lachapelle, J M
1993-11-01
We performed patch tests with Dermatophagoides pteronyssinus (Dp) antigens from 2 different sources in 355 non-randomly selected patients with atopic dermatitis (AD) and 398 subjects of a control group. The study demonstrated that contact sensitization to mites occurred in an appreciable % of AD cases (20.8%), using commonly available assay products. The differences recorded between the 2 materials tested were related to the concentration of P1 antigen. Non-atopic patients rarely showed positive reactions to Dp (0.75%), when strict criteria for readings were applied and if 2 readings were performed. Patients with positive patch tests did not necessarily show positive immediate skin tests. It would be useful to carry out tests systematically in atopic patients, even if it is not yet known what modern treatment would be best for the patient. Laboratories still do not provide standardized house dust mite preparations--measuring and codifying their biological activity--for use in patch tests. It is to be hoped that the extension of this type of test will lead to the production of better test materials, in syringes with homogeneous dispersion and concentration.
Combined evaluation of commonly used techniques, including PCR, for diagnosis of mouse fur mites.
Karlsson, Eleanor M; Pearson, Laura M; Kuzma, Kristen M; Burkholder, Tanya H
2014-01-01
Our study evaluated and compared the false-negative rates (FNR) of a wide array of fur-mite diagnostic tests, including 2 postmortem tests (pelt exam and sticky paper) and 3 antemortem tests (adhesive tape, fur pluck, and PCR). Past publications examining fur-mite diagnostic techniques primarily used paired comparisons, evaluating tests by their level of agreement with only one other test. However, different combinations or pairs of diagnostics are used in the different studies, making the results of these comparisons difficult to interpret across all available diagnostics. In the current study, mice from a conventionally maintained colony endemic for Myobia musculi were identified as positive based on at least one positive diagnostic test. From this pool of positive animals, the FNR of all tests were quantified. The PCR assay and the pelt exam performed the best, with 0% and 2% FNR respectively, whereas tape, fur-pluck, and sticky-paper tests showed 24%, 26%, and 36% FNR, respectively. Our study shows that for mice in a colony naturally infested with Myobia musculi, PCR testing can be used for reliable antemortem detection, and pelt exam performed by experienced examiners is reliable for postmortem detection.
The relationship between regular sports participation and vigilance in male and female adolescents.
Ballester, Rafael; Huertas, Florentino; Yuste, Francisco Javier; Llorens, Francesc; Sanabria, Daniel
2015-01-01
The present study investigated the relationship between regular sport participation (soccer) and vigilance performance. Two groups of male and female adolescents differentiated in terms of their sport participation (athletes, n = 39, and non-athletes, n = 36) took part in the study. In one session, participants performed the Leger Multi-stage fitness test to estimate their aerobic fitness level. In the other session, participants completed the Psychomotor Vigilance Task (PVT) to evaluate their vigilance performance. Perceived arousal prior to the task and motivation toward the task were also measured in the PVT session. The results revealed that athletes had better cardiovascular fitness and showed better performance in the PVT. However, correlation analyses did not show any significant relationship between cardiovascular fitness and performance in the PVT. Athletes showed larger scores in motivation and perceived arousal measures with respect to non-athletes, although, once again, these variables were not correlated with PVT performance. Gender differences were observed only in the Leger test, with males showing greater fitness level than females. The major outcome of this research points to a positive relationship between regular sport participation and vigilance during adolescence. This relationship did not seem to be influenced by gender, perceived arousal, motivation toward the task or cardiovascular fitness. We discuss our results in terms of the different hypotheses put forward in the literature to explain the relationship between physical activity and cognitive functioning.
Measurements of Integration Gain for the Cospas-Sarsat System from Geosynchronous Satellites
NASA Technical Reports Server (NTRS)
Klein-Lebbink, Elizabeth; Christo, James; Peters, Robert; Nguyen, Xuan
2015-01-01
The GOES-R satellite is the first satellite to use a standard straight bent pipe transponder with no on-board re-modulation to support Search and Rescue (SAR) operations. Here, we report on the link measurements with a high fidelity satellite transponder simulator made up of satellite EDU (Engineering Design Units) components using an uplink from a beacon simulator and received by a GEOLUT (GEOsynchronous satellite Local User Terminal). We also report on the first ever measurements showing the performance gain obtained by the signal integration performed by the GEOLUT. In addition, a simulator made of commercially available off-the-shelf components assembled to develop the test plan was found to perform very close to the high fidelity simulator. In this paper, we describe what message integration is, how it is implemented in the particular satellite receiving station model used for this tests, and show the measured improvement in message decoding due to this integration process. These are the first tests to quantify the integration gain and are the first tests on the new SARSAT standard for the bent pipe (no onboard re-modulation) repeater used in GOES-R. An inexpensive satellite simulator to run test scripts built from off the shelf components was also found to have the same performance as a high fidelity simulator using actual satellite EDUs.
Castagna, Carlo; Abt, Grant; D'Ottavio, Stefano
2005-11-01
The aim of this study was to examine yo-yo intermittent recovery test (Yo-Yo test) and 12-minute run test (12MRT) performances in experienced soccer referees of different competitive levels. Three groups (n = 14 each) of experienced Italian soccer referees officiating in the first (series AB, top-level), third (series C, medium-level), and fourth (series D, low-level) division, were randomly submitted to the 12MRT and the Yo-Yo test during 2 testing sessions, 48-hours apart. 12MRT performances were 3,000 +/- 112 m; 2,894 +/- 99 m; and 2,896 +/- 171 m for top-level, medium-level and low-level referees, respectively (p > 0.05). In the Yo-Yo test, the top-level, medium-level, and low-level referees covered 1,874 +/- 431 m; 1,360 +/- 172 m; and 1,272 +/- 215 m, respectively. The test performances of top-level referees in the Yo-Yo test was significantly different from those scored by medium-level and low-level referees (p < 0.05). After the Yo-Yo test, blood lactate concentrations (BLC) were higher in the medium-level and low-level referees compared with the top-level referees (p < 0.05). The results of the present study show that the Yo-Yo test and not the 12MRT can discriminate endurance performance in experienced elite level soccer referees. With respect to its discriminative and match performance validity, the Yo-Yo test may be considered a relevant field test to assess endurance preparedness for experienced soccer referees and a useful tool in talent selection.
The influence of cellulose nanocrystal additions on the performance of cement paste
Yizheng Cao; Pablo Zavaterri; Jeff Youngblood; Robert Moon; Jason Weiss
2015-01-01
The influence of cellulose nanocrystals (CNCs) addition on the performance of cement paste was investigated. Our mechanical tests show an increase in the flexural strength of approximately 30% with only 0.2% volume of CNCs with respect to cement. Isothermal calorimetry (IC) and thermogravimetric analysis (TGA) show that the degree of hydration (DOH) of the cement paste...
Mehdizadeh, Leila; Sturrock, Alison; Dacre, Jane
2015-04-21
The General Medical Council's Fitness to Practise investigations may involve a test of competence for doctors with performance concerns. Concern has been raised about the suitability of the test format for doctors who qualified before the introduction of Single Best Answer and Objective Structured Clinical Examination assessments, both of which form the test of competence. This study explored whether the examination formats used in the tests of competence are fair to long standing doctors who have undergone fitness to practise investigation. A retrospective cohort design was used to determine an association between year of primary medical qualification and doctors' test of competence performance. Performance of 95 general practitioners under investigation was compared with a group of 376 volunteer doctors. We analysed performance on knowledge test, OSCE overall, and three individual OSCE stations using Spearman's correlation and regression models. Doctors under investigation performed worse on all test outcomes compared to the comparison group. Qualification year correlated positively with performance on all outcomes except for physical examination (e.g. knowledge test r = 0.48, p < 0.001 and OSCE r = 0.37, p < 0.001). Qualification year was associated with test performance in doctors under investigation even when controlling for sex, ethnicity and qualification region. Regression analyses showed that qualification year was associated with knowledge test, OSCE and communication skills performance of doctors under investigation when other variables were controlled for. Among volunteer doctors this was not the case and their performance was more strongly related to where they qualified and their ethnic background. Furthermore, volunteer doctors who qualified before the introduction of Single Best Answer and OSCE assessments, still outperformed their peers under investigation. Earlier graduates under fitness to practise investigation performed less well on the test of competence than their more recently qualified peers under investigation. The performance of the comparator group tended to stay consistent irrespective of year qualified. Our results suggest that the test format does not disadvantage early qualified doctors. We discuss findings in relation to the GMC's fitness to practise procedures and suggest alternative explanations for the poorer performance of long standing doctors under investigation.
Rezaei, Fatemeh; Hosseini Ramaghani, Nasrin Alsadat; Fazio, Rachel L
2017-04-01
Studies have reported that the presence of a third party observer (TPO) during neuropsychological assessments negatively affects the test performance of the examinee. The present study aimed to investigate the effects of a TPO and trait anxiety on neuropsychological performance according to Attentional Control Theory (ACT). A sample of college students was recruited (n = 318) and then 80 participants were selected to represent the high and low trait anxiety groups. Participants of each of group were randomly assigned to either the NTPO (non-TPO) or TPO conditions. The State-Trait Anxiety Inventory - Trait measure (STAI-T), Wisconsin Card Sorting Test (WCST-64), Stroop test, and Rating Scale for Mental Effort (RSME) were administered to both groups. To analyze the data, univariate ANOVAs were conducted. The results indicated that under the conditions without a TPO the group with high trait anxiety had poorer processing efficiency, but under the conditions with a TPO they had poorer processing efficiency and poorer performance effectiveness than the group with low trait anxiety. In addition, the group with low trait anxiety showed poorer processing efficiency in the TPO compared to non-TPO condition. These findings provide support for the hypotheses of ACT regarding the relation between observer presence and poorer performance on neuropsychological tests, with individuals with higher trait anxiety showing greater negative effects. Implications and suggestions for further research are discussed.
Hirjak, Dusan; Sambataro, Fabio; Remmele, Barbara; Kubera, Katharina M; Schröder, Johannes; Seidl, Ulrich; Thomann, Anne K; Maier-Hein, Klaus H; Wolf, Robert C; Thomann, Philipp A
2017-08-31
The clock drawing test (CDT) is one of the worldwide most used screening tests for Alzheimer's disease (AD). MRI studies have identified temporo-parietal regions being involved in CDT impairment. However, the contributions of specific hippocampal subfields and adjacent extrahippocampal structures to CDT performance in AD and mild cognitive impairment (MCI) have not been investigated so far. It is unclear whether morphological alterations or CDT score, or a combination of both, are able to predict AD. 38 AD patients, 38 MCI individuals and 31 healthy controls underwent neuropsychological assessment and MRI at 3 Tesla. FreeSurfer 5.3 was used to perform hippocampal parcellation. We used a collection of statistical methods to better understand the relationship between CDT and hippocampal formation. We also tested the clinical feasibility of this relationship when predicting AD. Impaired CDT performance in AD was associated with widespread atrophy of the cornu ammonis, presubiculum, and subiculum, whereas MCI subjects showed CDT-related alterations of the CA4-dentate gyrus and subiculum. CDT correlates in AD and MCI showed regional and quantitative overlap. Importantly, CDT score was the best predictor of AD. Our findings lend support for an involvement of different hippocampal subfields in impaired CDT performance in AD and MCI. CDT seems to be more efficient than subfield imaging for predicting AD.
de Castro, Marcus Vasconcelos; Bissaco, Márcia Aparecida Silva; Panccioni, Bruno Marques; Rodrigues, Silvia Cristina Martini; Domingues, Andreia Miranda
2014-01-01
In this study, we show the effectiveness of a virtual environment comprising 18 computer games that cover mathematics topics in a playful setting and that can be executed on the Internet with the possibility of player interaction through chat. An arithmetic pre-test contained in the Scholastic Performance Test was administered to 300 children between 7 and 10 years old, including 162 males and 138 females, in the second grade of primary school. Twenty-six children whose scores showed a low level of mathematical knowledge were chosen and randomly divided into the control (CG) and experimental (EG) groups. The EG participated to the virtual environment and the CG participated in reinforcement using traditional teaching methods. Both groups took a post-test in which the Scholastic Performance Test (SPT) was given again. A statistical analysis of the results using the Student's t-test showed a significant learning improvement for the EG and no improvement for the CG (p≤0.05). The virtual environment allows the students to integrate thought, feeling and action, thus motivating the children to learn and contributing to their intellectual development. PMID:25068511
Performance evaluation of infrared imaging system in field test
NASA Astrophysics Data System (ADS)
Wang, Chensheng; Guo, Xiaodong; Ren, Tingting; Zhang, Zhi-jie
2014-11-01
Infrared imaging system has been applied widely in both military and civilian fields. Since the infrared imager has various types and different parameters, for system manufacturers and customers, there is great demand for evaluating the performance of IR imaging systems with a standard tool or platform. Since the first generation IR imager was developed, the standard method to assess the performance has been the MRTD or related improved methods which are not perfect adaptable for current linear scanning imager or 2D staring imager based on FPA detector. For this problem, this paper describes an evaluation method based on the triangular orientation discrimination metric which is considered as the effective and emerging method to evaluate the synthesis performance of EO system. To realize the evaluation in field test, an experiment instrument is developed. And considering the importance of operational environment, the field test is carried in practical atmospheric environment. The test imagers include panoramic imaging system and staring imaging systems with different optics and detectors parameters (both cooled and uncooled). After showing the instrument and experiment setup, the experiment results are shown. The target range performance is analyzed and discussed. In data analysis part, the article gives the range prediction values obtained from TOD method, MRTD method and practical experiment, and shows the analysis and results discussion. The experimental results prove the effectiveness of this evaluation tool, and it can be taken as a platform to give the uniform performance prediction reference.
Hsu, Hsiu-Yun; Kuo, Yao-Lung; Jou, I-Ming; Su, Fong-Chin; Chiu, Haw-Yen; Kuo, Li-Chieh
2014-04-01
To investigate how the severity levels revealed in a nerve conduction study (NCS) affect the results of the Manual Tactile Test (MTT) for patients with carpal tunnel syndrome (CTS), and to examine the relationships between the results of the MTT and precision pinch performance. Case-control studies. Hospital and local community. Patients with CTS (N=70) with 119 affected hands were studied. A control group matched by age, sex, and hand dominance was also recruited. Not applicable. CTS severity was determined based on NCS findings. The MTT, traditional sensory tests, and precision pinch performance were used to examine the functional sensory status of the hand from different perspectives. The patients with CTS exhibited deterioration in all of the sensibility tests (P<.001). The results showed that the MTT could classify subgroups of severity in CTS (P<.001). A moderate correlation was found between the results of the MTT and precision pinch performance (r=.526-.585, P<.001). Multiple linear regression analysis showed that the MTT results were useful indicators for predicting precision pinch performance and differentiating severity in subjects with CTS (r(2)=.376 and .323, respectively). The findings indicate that the MTT could be a valid and useful assessment for hand sensibility and prehensile pinch performance in patients with CTS. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
García-Pinillos, Felipe; Delgado-Floody, Pedro; Martínez-Salazar, Cristian; Latorre-Román, Pedro Á.
2018-01-01
Abstract The present study analyzed the acute effects of an incremental running test on countermovement jump (CMJ) and handgrip strength performance in endurance athletes, considering the effect of post-exercise recovery time and sex. Thirty-three recreationally trained long-distance runners, 20 men and 13 women, participated voluntarily in this study. The participants performed the Léger test, moreover, the CMJ and handgrip strength tests were carried out before and after the running test and during different stages of recovery (at the 1st min of recovery (posttest1), 5th min of recovery (posttest2), and 10th min of recovery (posttest3)). Two-way analysis of variance revealed a significant improvement in the CMJ (pre-posttest1, p = 0.001) and handgrip strength (pre-posttest2, p = 0.017) during recovery time. The Pearson’s Chi-2 test showed no significant relationship (p ≥ 0.05) between sex and post-activation potentiation (PAP). A linear regression analysis pointed to heart rate recovery as a predictive factor of CMJ improvement (PAP). In conclusion, despite significant fatigue reached during the Léger test, the long-distance runners did not experience an impaired CMJ and handgrip strength performance, either men or women, achieving an improvement (PAP) in posttest conditions. The results obtained showed no significant relationship between sex and PAP. Moreover, significant effect of recovery after running at high intensity on CMJ performance and handgrip strength was found. Finally, the data suggest that PAP condition can be predicted by heart rate recovery in endurance runners. PMID:29599872
The performance-perceptual test and its relationship to unaided reported handicap.
Saunders, Gabrielle H; Forsline, Anna; Fausti, Stephen A
2004-04-01
Measurement of hearing aid outcomes is necessary for demonstration of treatment efficacy, third-party payment, and cost-benefit analysis. Outcomes are usually measured with hearing-related questionnaires and/or tests of speech recognition. However, results from these two types of test often conflict. In this paper, we provide data from a new test measure, known as the Performance-Perceptual Test (PPT), in which subjective and performance aspects of hearing in noise are measured using the same test materials and procedures. A Performance Speech Reception Threshold (SRTN) and a Perceptual SRTN are measured using the Hearing In Noise Test materials and adaptive procedure. A third variable, the discrepancy between these two SRTNs, is also computed. It measures the accuracy with which subjects assess their own hearing ability and is referred to as the Performance-Perceptual Discrepancy (PPDIS). One hundred seven subjects between 24 and 83 yr of age took part. Thirty-three subjects had normal hearing, while the remaining seventy-four had symmetrical sensorineural hearing loss. Of the subjects with impaired hearing, 24 wore hearing aids and 50 did not. All subjects underwent routine audiological examination and completed the PPT and the Hearing Handicap Inventory for the Elderly/Adults on two occasions, between 1 and 2 wk apart. The PPT was conducted for unaided listening with the masker level set to 50, 65, and 80 dB SPL. PPT data show that the subjects with normal hearing have significantly better Performance and Perceptual SRTNs at each test level than the subjects with impaired hearing but that PPDIS values do not differ between the groups. Test-retest reliability for the PPT is excellent (r-values > 0.93 for all conditions). Stepwise multiple regression analysis showed that the Performance SRTN, the PPDIS, and age explain 40% of the variance in reported handicap (Hearing Handicap Inventory for the Elderly/Adults scores). More specifically, poorer performance, underestimation of hearing ability and younger age result in greater reported handicap, and vice versa. Reported handicap consists of a performance component and a (mis)perception component, as measured by the Performance SRTN and the PPDIS respectively. The PPT should thus prove to be a valuable tool for better understanding why some individuals complain of hearing difficulties but have only a mild hearing loss or conversely report few difficulties in the presence of substantial impairment. The measure would thus seem to provide both an explanation and a counseling tool for patients for whom there is a mismatch between reported and measured hearing difficulties.
Rossi, R; Pascolo, P B
2015-09-01
Driving in degraded psychophysical conditions, such as under the influence of alcohol or drugs but also in a state of fatigue or drowsiness, is a growing problem. The current roadside tests used for detecting drugs from drivers suffer various limitations, while impairment is subjective and does not necessarily correlate with drug metabolite concentration found in body fluids. This work is a validation step towards the study of feasibility of a novel test conceived to assess psychophysical conditions of individuals performing at-risk activities. Motor gestures, long-term retention and learning phase related to the protocol are analysed in unimpaired subjects. The protocol is a divided attention test, which combines a critical tracking test achieved with postural movements and a visual choice reaction test. Ten healthy subjects participated in a first set of trials and in a second set after about six months. Each session required the carrying out of the test for ten times in order to investigate learning effect and performance over repetitions. In the first set the subjects showed a learning trend up to the third trial, whilst in the second set of trials they showed motor retention. Nevertheless, the overall performance did not significantly improve. Gestures are probably retained due to the type of tasks and the way in which the instructions are conveyed to the subjects. Moreover, motor retention after a short training suggests that the protocol is easy to learn and understand. Implications for roadside test usage and comparison with current tests are also discussed. Copyright © 2015 Elsevier Ltd. All rights reserved.
Development of a high efficiency thin silicon solar cell. [fabrication and stability tests
NASA Technical Reports Server (NTRS)
Lindmayer, J.
1976-01-01
One hundred thin (120 microns to 260 microns) silicon-aluminum solar cells were fabricated and tested. Silicon slices were prepared, into which an aluminum alloy was evaporated over a range of temperatures and times. Antireflection coatings of tantalum oxide were applied to the cells. Reflectance of the silicon-aluminum interfaces was correlated to alloy temperature (graphs are shown). Optical measurements of the rear surface-internal reflectance of the cells were performed using a Beckman spectrophotometer. An improved gridline pattern was evaluated and stability tests (thermal cycling tests) were performed. Results show that: (1) a high-index, high-transmittance antireflection coating was obtained; (2) the improved metallization of the cells gave a 60 percent rear surface-internal reflectance, and the cells displayed excellent fill factors and blue response of the spectrum; (3) an improved gridline pattern (5 micron linewidths compared to 13 micron linewidths) resulted in a 1.3 percent improvement in short circuit currents; and (4) the stability tests showed no change in cell properties.
Application-level regression testing framework using Jenkins
Budiardja, Reuben; Bouvet, Timothy; Arnold, Galen
2017-09-26
Monitoring and testing for regression of large-scale systems such as the NCSA's Blue Waters supercomputer are challenging tasks. In this paper, we describe the solution we came up with to perform those tasks. The goal was to find an automated solution for running user-level regression tests to evaluate system usability and performance. Jenkins, an automation server software, was chosen for its versatility, large user base, and multitude of plugins including collecting data and plotting test results over time. We also describe our Jenkins deployment to launch and monitor jobs on remote HPC system, perform authentication with one-time password, and integratemore » with our LDAP server for its authorization. We show some use cases and describe our best practices for successfully using Jenkins as a user-level system-wide regression testing and monitoring framework for large supercomputer systems.« less
Application-level regression testing framework using Jenkins
DOE Office of Scientific and Technical Information (OSTI.GOV)
Budiardja, Reuben; Bouvet, Timothy; Arnold, Galen
Monitoring and testing for regression of large-scale systems such as the NCSA's Blue Waters supercomputer are challenging tasks. In this paper, we describe the solution we came up with to perform those tasks. The goal was to find an automated solution for running user-level regression tests to evaluate system usability and performance. Jenkins, an automation server software, was chosen for its versatility, large user base, and multitude of plugins including collecting data and plotting test results over time. We also describe our Jenkins deployment to launch and monitor jobs on remote HPC system, perform authentication with one-time password, and integratemore » with our LDAP server for its authorization. We show some use cases and describe our best practices for successfully using Jenkins as a user-level system-wide regression testing and monitoring framework for large supercomputer systems.« less
Teklu, Berhan M; Retta, Negussie; Van den Brink, Paul J
2016-08-01
The aims of the present study were to present a methodology for toxicity tests that can be used when analytical resources to verify the test concentrations are limited, and to evaluate whether the sensitivity of a limited number of Ethiopian species to pesticides differs from literature values for, mainly, temperate species. Acute toxicity tests were performed using three Ethiopian aquatic invertebrate species, one crustacean (Diaphanosoma brachyurum) and two insects (Anopheles pharoensis and Culex pipiens) and using the pesticides endosulfan and diazinon. All species-pesticide combinations were tested in duplicate to estimate the consistency, i.e. the intra-laboratory variation, in test results. Daphnia magna was tested as well to allow the test results to be compared directly with values from the literature. Results indicate that the differences between the EC50s obtained for D. magna in this study and those reported in the literature were less than a factor of 2. This indicates that the methodology used is able to provide credible toxicity values. The results of the duplicated tests showed intra-laboratory variation in EC50 values of up to a factor of 3, with one test showing a difference of a factor of 6 at 48 h. Comparison with available literature results for arthropod species using species sensitivity distributions indicated that the test results obtained in this study fit well in the log-normal distribution of the literature values. We conclude that the methodology of performing multiple tests to check for consistency of test results and performing tests with D. magna for comparison with literature values to check for accuracy is able to provide reliable effect threshold levels and that the tested Ethiopian species did not differ in sensitivity from the arthropod species reported on in the literature.
Using integrated information systems in supply chain management
NASA Astrophysics Data System (ADS)
Gonzálvez-Gallego, Nicolás; Molina-Castillo, Francisco-Jose; Soto-Acosta, Pedro; Varajao, Joao; Trigo, Antonio
2015-02-01
The aim of this paper is to empirically test not only the direct effects of information and communication technology (ICT) capabilities and integrated information systems (IS) on firm performance, but also the moderating role of IS integration along the supply chain in the relationship between ICT external and capabilities and business performance. Data collected from 102 large Iberian firms from Spain and Portugal are used to test the research model. The hierarchical multiple regression analysis is employed to test the direct effects and the moderating relationships proposed. Results show that external and internal ICT capabilities are important drivers of firm performance, while merely having integrated IS do not lead to better firm performance. In addition, a moderating effect of IS integration in the relationship between ICT capabilities and business performance is found, although this integration only contributes to firm performance when it is directed to connect with suppliers or customers rather than when integrating the whole supply chain.
A Historical Review of Cermet Fuel Development and the Engine Performance Implications
NASA Technical Reports Server (NTRS)
Stewart, Mark E. M.
2015-01-01
This paper reviews test data for cermet fuel samples developed in the 1960's to better quantify Nuclear Thermal Propulsion (NTP) cermet engine performance, and to better understand contemporary fuel testing results. Over 200 cermet (W-UO2) samples were tested by thermally cycling to 2500 deg (2770 K) in hydrogen. The data indicates two issues at high temperatures: the vaporization rate of UO2 and the chemical stability of UO2. The data show that cladding and chemical stabilizers each result in large, order of magnitude improvements in high temperature performance, while other approaches yield smaller, incremental improvements. Data is very limited above 2770 K, and this complicates predictions of engine performance at high Isp. The paper considers how this material performance data translates into engine performance. In particular, the location of maximum temperature within the fuel element and the effect of heat deposition rate are examined.
Investigating human cognitive performance during spaceflight
NASA Astrophysics Data System (ADS)
Pattyn, Nathalie; Migeotte, Pierre-Francois; Demaeseleer, Wim; Kolinsky, Regine; Morais, Jose; Zizi, Martin
2005-08-01
Although astronauts' subjective self-evaluation of cognitive functioning often reports impairments, to date most studies of human higher cognitive functions in space never yielded univocal results. Since no golden standard exists to evaluate the higher cognitive functions, we proposed to assess astronaut's cognitive performance through a novel series of tests combined with the simultaneous recording of physiological parameters. We report here the validation of our methodology and the cognitive results of this testing on the cosmonauts from the 11 days odISSsea mission to the ISS (2002) and on a control group of pilots, carefully matched to the characteristics of the subjects. For the first time, we show a performance decrement in higher cognitive functions during space flight. Our results show a significant performance decrement for inflight measurement, as well as measurable variations in executive control of cognitive functions. Taken together, our data establish the validity of our methodology and the presence of a different information processing in operational conditions.
The Influence of Restricted Visual Feedback on Dribbling Performance in Youth Soccer Players.
Fransen, Job; Lovell, Thomas W J; Bennett, Kyle J M; Deprez, Dieter; Deconinck, Frederik J A; Lenoir, Matthieu; Coutts, Aaron J
2017-04-01
The aim of the current study was to examine the influence of restricted visual feedback using stroboscopic eyewear on the dribbling performance of youth soccer players. Three dribble test conditions were used in a within-subjects design to measure the effect of restricted visual feedback on soccer dribbling performance in 189 youth soccer players (age: 10-18 y) classified as fast, average or slow dribblers. The results showed that limiting visual feedback increased dribble test times across all abilities. Furthermore, the largest performance decrement between stroboscopic and full vision conditions was in fast dribblers, showing that fast dribblers were most affected by reduced visual information. This may be due to a greater dependency on visual feedback at increased speeds, which may limit the ability to maintain continuous control of the ball. These findings may have important implications for the development of soccer dribbling ability.
NASA Technical Reports Server (NTRS)
Roelke, R. J.; Haas, J. E.
1984-01-01
The aerodynamic performance of a redesigned compressor drive turbine of the gas turbine engine is determined in air at nominal inlet conditions of 325 K and 0.8 bar absolute. The turbine is designed with a lower flow factor, higher rotor reaction and a redesigned inlet volute compared to the first turbine. Comparisons between this turbine and the originally designed turbine show about 2.3 percentage points improvement in efficiency at the same rotor tip clearance. Two versions of the same rotor are tested: (1) an as cast rotor, and (2) the same rotor with reduced surface roughness. The effect of reducing surface roughness is about one half percentage point improvement in efficiency. Tests made to determine the effect of Reynolds number on the turbine performance show no effect for the range from 100,000 to 500,000.
Exploring the gender gap in the conceptual survey of electricity and magnetism
NASA Astrophysics Data System (ADS)
Henderson, Rachel; Stewart, Gay; Stewart, John; Michaluk, Lynnette; Traxler, Adrienne
2017-12-01
The "gender gap" on various physics conceptual evaluations has been extensively studied. Men's average pretest scores on the Force Concept Inventory and Force and Motion Conceptual Evaluation are 13% higher than women's, and post-test scores are on average 12% higher than women's. This study analyzed the gender differences within the Conceptual Survey of Electricity and Magnetism (CSEM) in which the gender gap has been less well studied and is less consistent. In the current study, data collected from 1407 students (77% men, 23% women) in a calculus-based physics course over ten semesters showed that male students outperformed female students on the CSEM pretest (5%) and post-test (6%). Separate analyses were conducted for qualitative and quantitative problems on lab quizzes and course exams and showed that male students outperformed female students by 3% on qualitative quiz and exam problems. Male and female students performed equally on the quantitative course exam problems. The gender gaps within CSEM post-test scores, qualitative lab quiz scores, and qualitative exam scores were insignificant for students with a CSEM pretest score of 25% or less but grew as pretest scores increased. Structural equation modeling demonstrated that a latent variable, called Conceptual Physics Performance/Non-Quantitative (CPP/NonQnt), orthogonal to quantitative test performance was useful in explaining the differences observed in qualitative performance; this variable was most strongly related to CSEM post-test scores. The CPP/NonQnt of male students was 0.44 standard deviations higher than female students. The CSEM pretest measured CPP/NonQnt much less accurately for women (R2=4 % ) than for men (R2=17 % ). The failure to detect a gender gap for students scoring 25% or less on the pretest suggests that the CSEM instrument itself is not gender biased. The failure to find a performance difference in quantitative test performance while detecting a gap in qualitative performance suggests the qualitative differences do not result from psychological factors such as science anxiety or stereotype threat.
Mauseth, Richard; Lord, Sandra M; Hirsch, Irl B; Kircher, Robert C; Matheson, Don P; Greenbaum, Carla J
2015-09-14
Under controlled conditions, the Dose Safety artificial pancreas (AP) system controller, which utilizes "fuzzy logic" (FL) methodology to calculate and deliver appropriate insulin dosages based on changes in blood glucose, successfully managed glycemic excursions. The aim of this study was to show whether stressing the system with pizza (high carbohydrate/high fat) meals and exercise would reveal deficits in the performance of the Dose Safety FL controller (FLC) and lead to improvements in the dosing matrix. Ten subjects with type 1 diabetes (T1D) were enrolled and participated in 30 studies (17 meal, 13 exercise) using 2 versions of the FLC. After conducting 13 studies with the first version (FLC v2.0), interim results were evaluated and the FLC insulin-dosing matrix was modified to create a new controller version (FLC v2.1) that was validated through regression testing using v2.0 CGM datasets prior to its use in clinical studies. The subsequent 17 studies were performed using FLC v2.1. Use of FLC v2.1 vs FLC v2.0 in the pizza meal tests showed improvements in mean blood glucose (205 mg/dL vs 232 mg/dL, P = .04). FLC v2.1 versus FLC v2.0 in exercise tests showed improvements in mean blood glucose (146 mg/dL vs 201 mg/dL, P = .004), percentage time spent >180 mg/dL (19.3% vs 46.7%, P = .001), and percentage time spent 70-180 mg/dL (80.0% vs 53.3%, P = .002). Stress testing the AP system revealed deficits in the FLC performance, which led to adjustments to the dosing matrix followed by improved FLC performance when retested. © 2015 Diabetes Technology Society.
Johnson, C. Anderson; Xiao, Lin; Palmer, Paula; Sun, Ping; Wang, Qiong; Wei, Yonglan; Jia, Yong; Grenard, Jerry L.; Stacy, Alan W.; Bechara, Antoine
2011-01-01
The primary aim of this study was to test the hypothesis that adolescent binge drinkers, but not lighter drinkers, would show signs of impairment on tasks of affective decision-making as measured by the Iowa Gambling Test (IGT), when compared to adolescents who never drank. We tested 207 10th grade adolescents in Chengdu City, China, using two versions of the IGT, the original and a variant, in which the reward/punishment contingencies were reversed. This enables one to distinguish among different possibilities of impaired decision-making, such as insensitivity to long-term consequences, or hypersensitivity to reward. Furthermore, we tested working memory capacity using the Self-ordered Pointing Test (SOPT). Paper and pencil questionnaires were used to assess drinking behaviors and school academic performance. Results indicated that relative to never-drinkers, adolescent binge drinkers, but not other (ever, past 30-day) drinkers, showed significantly lower net scores on the original version of the IGT especially in the latter trials. Furthermore, the profiles of behavioral performance from the original and variant versions of the IGT were consistent with a decision-making impairment attributed to hypersensitivity to reward. In addition, working memory and school academic performance revealed no differences between drinkers (at all levels) and never-drinkers. Logistic regression analysis showed that after controlling for demographic variables, working memory, and school academic performance, the IGT significantly predicted binge-drinking. These findings suggest that a “myopia” for future consequences linked to hypersensitivity to reward is a key characteristic of adolescents with binge-drinking behavior, and that underlying neural mechanisms for this “myopia” for future consequences may serve as a predisposing factor that renders some adolescents more susceptible to future addictive behaviors. PMID:17996909
Rodríguez-Rosell, David; Mora-Custodio, Ricardo; Franco-Márquez, Felipe; Yáñez-García, Juan M; González-Badillo, Juan J
2017-01-01
Rodríguez-Rosell, D, Mora-Custodio, R, Franco-Márquez, F, Yáñez-García, JM, González-Badillo, JJ. Traditional vs. sport-specific vertical jump tests: reliability, validity, and relationship with the legs strength and sprint performance in adult and teen soccer and basketball players. J Strength Cond Res 31(1): 196-206, 2017-The vertical jump is considered an essential motor skill in many team sports. Many protocols have been used to assess vertical jump ability. However, controversy regarding test selection still exists based on the reliability and specificity of the tests. The main aim of this study was to analyze the reliability and validity of 2 standardized (countermovement jump [CMJ] and Abalakov jump [AJ]) and 2 sport-specific (run-up with 2 [2-LEGS] or 1 leg [1-LEG] take-off jump) vertical jump tests, and their usefulness as predictors of sprint and strength performance for soccer (n = 127) and basketball (n = 59) players in 3 different categories (Under-15, Under-18, and Adults). Three attempts for each of the 4 jump tests were recorded. Twenty-meter sprint time and estimated 1 repetition maximum in full squat were also evaluated. All jump tests showed high intraclass correlation coefficients (0.969-0.995) and low coefficients of variation (1.54-4.82%), although 1-LEG was the jump test with the lowest absolute and relative reliability. All selected jump tests were significantly correlated (r = 0.580-0.983). Factor analysis resulted in the extraction of one principal component, which explained 82.90-95.79% of the variance of all jump tests. The 1-LEG test showed the lowest associations with sprint and strength performance. The results of this study suggest that CMJ and AJ are the most reliable tests for the estimation of explosive force in soccer and basketball players in different age categories.
High Ability and Learner Characteristics
ERIC Educational Resources Information Center
Hindal, Huda; Reid, Norman; Whitehead, Rex
2013-01-01
The outstandingly able learner has been conceptualised, in terms of test and examination performance, as the learner showing superior academic performance which is markedly better than that of peers and in ways regarded as of value by wider society. In Kuwait, such superior examination performance leads to a classification regarded as being…
Locus of Control and Neuropsychological Performance in Chronic Alcoholics.
ERIC Educational Resources Information Center
Shelton, M. D.; And Others
1982-01-01
Examined correlated neuropsychological performance in male chronic alcoholics and non-alcoholic controls. Results showed external locus of control (LOC-E) scores to predict performance on neuropsychological tests in alcoholics but not in controls. Suggests the LOC-E variables cannot account for the widespread differences between the groups on…
Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Hofmann, Jörg; Izopet, Jacques; Kühn, Sebastian; Lombardi, Alessandra; Mancon, Alessandro; Marcos, Mª Angeles; Mileto, Davide; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel
2017-07-01
Viral load monitoring is essential for patients under treatment for HIV. Beckman Coulter has developed the VERIS HIV-1 Assay for use on the novel, automated DxN VERIS Molecular Diagnostics System. ¥ OBJECTIVES: Evaluation of the clinical performance of the new quantitative VERIS HIV-1 Assay at multiple EU laboratories. Method comparison with the VERIS HIV-1 Assay was performed with 415 specimens at 5 sites tested with COBAS ® AmpliPrep/COBAS ® TaqMan ® HIV-1 Test, v2.0, 169 specimens at 3 sites tested with RealTime HIV-1 Assay, and 202 specimens from 2 sites tested with VERSANT HIV-1 Assay. Patient monitoring sample results from 4 sites were also compared. Bland-Altman analysis showed the average bias between VERIS HIV-1 Assay and COBAS HIV-1 Test, RealTime HIV-1 Assay, and VERSANT HIV-1 Assay to be 0.28, 0.39, and 0.61 log 10 cp/mL, respectively. Bias at low end levels below 1000cp/mL showed predicted bias to be <0.3 log 10 cp/mL for VERIS HIV-1 Assay versus COBAS HIV-1 Test and RealTime HIV-1 Assay, and <0.5 log 10 cp/mL versus VERSANT HIV-1 Assay. Analysis on 174 specimens tested with the 0.175mL volume VERIS HIV-1 Assay and COBAS HIV-1 Test showed average bias of 0.39 log 10 cp/mL. Patient monitoring results using VERIS HIV-1 Assay demonstrated similar viral load trends over time to all comparators. The VERIS HIV-1 Assay for use on the DxN VERIS System demonstrated comparable clinical performance to COBAS ® HIV-1 Test, RealTime HIV-1 Assay, and VERSANT HIV-1 Assay. Copyright © 2017 Elsevier B.V. All rights reserved.
Friedrich, Juliane; Brand, Bodo; Ponsuksili, Siriluck; Graunke, Katharina L; Langbein, Jan; Knaust, Jacqueline; Kühn, Christa; Schwerin, Manfred
2016-02-01
Behaviour traits of cattle have been reported to affect important production traits, such as meat quality and milk performance as well as reproduction and health. Genetic predisposition is, together with environmental stimuli, undoubtedly involved in the development of behaviour phenotypes. Underlying molecular mechanisms affecting behaviour in general and behaviour and productions traits in particular still have to be studied in detail. Therefore, we performed a genome-wide association study in an F2 Charolais × German Holstein cross-breed population to identify genetic variants that affect behaviour-related traits assessed in an open-field and novel-object test and analysed their putative impact on milk performance. Of 37,201 tested single nucleotide polymorphism (SNPs), four showed a genome-wide and 37 a chromosome-wide significant association with behaviour traits assessed in both tests. Nine of the SNPs that were associated with behaviour traits likewise showed a nominal significant association with milk performance traits. On chromosomes 14 and 29, six SNPs were identified to be associated with exploratory behaviour and inactivity during the novel-object test as well as with milk yield traits. Least squares means for behaviour and milk performance traits for these SNPs revealed that genotypes associated with higher inactivity and less exploratory behaviour promote higher milk yields. Whether these results are due to molecular mechanisms simultaneously affecting behaviour and milk performance or due to a behaviour predisposition, which causes indirect effects on milk performance by influencing individual reactivity, needs further investigation. © 2015 Stichting International Foundation for Animal Genetics.
Aerogel Insulation Applications for Liquid Hydrogen Launch Vehicle Tanks
NASA Technical Reports Server (NTRS)
Fesmire, J. E.; Sass, J.
2007-01-01
Aerogel based insulation systems for ambient pressure environments were developed for liquid hydrogen (LH2) tank applications. Solutions to thermal insulation problems were demonstrated for the Space Shuttle External Tank (ET) through extensive testing at the Cryogenics Test Laboratory. Demonstration testing was performed using a 1/10th scale ET LH2 intertank unit and liquid helium as the coolant to provide the 20 K cold boundary temperature. Cryopumping tests in the range of 20K were performed using both constant mass and constant pressure methods. Long-duration tests (up to 10 hours) showed that the nitrogen mass taken up inside the intertank is reduced by a factor of nearly three for the aerogel insulated case as compared to the un-insulated (bare metal flight configuration) case. Test results including thermal stabilization, heat transfer effectiveness, and cryopumping confirm that the aerogel system eliminates free liquid nitrogen within the intertank. Physisorption (or adsorption) of liquid nitrogen within the fine pore structure of aerogel materials was also investigated. Results of a mass uptake method show that the sorption ratio (liquid nitrogen to aerogel beads) is about 62 percent by volume. A novel liquid nitrogen production method of testing the liquid nitrogen physical adsorption capacity of aerogel beads was also performed to more closely approximate the actual launch vehicle cooldown and thermal stabilization effects within the aerogel material. The extraordinary insulating effectiveness of the aerogel material shows that cryopumping is not an open-cell mass transport issue but is strictly driven by thermal communication between warm and cold surfaces. The new aerogel insulation technology is useful to solve heat transfer problem areas and to augment existing thermal protection systems on launch vehicles. Examples are given and potential benefits for producing launch systems that are more reliable, robust, reusable, and efficient are outlined.
The effect of clobazam and lorazepam on the psychomotor performance of anxious patients
Oblowitz, H.; Robins, A. H.
1983-01-01
1 Psychomotor performance and anxiety were measured in 70 anxious outpatients in a randomized double-blind, placebo-controlled trial comparing the 1,5-benzodiazepine clobazam (10 mg twice a day) to lorazepam (1 mg twice a day). Carefully selected tests were administered pre-treatment and at 2 and 9 days after treatment. Compliance was checked by blood assays. 2 All three treatment groups (clobazam, lorazepam and placebo) showed a significant improvement in anxiety over the course of the trial. There were no significant differences between the groups in terms of anxiety reduction. 3 All three groups improved over the course of the trial in choice reaction time, digit symbol substitution test, Purdue pegboard test (both hands) and in the Inglis paired-associate learning test: there were no significant differences between the groups with regard to these tests. There was no change in critical flicker fusion threshold over the trial period in any of the three groups. 4 The placebo and clobazam groups showed a significant improvement in two of the Purdue pegboard tests (preferred hand and assembly) from pre-treatment to 2 days but no further improvement at 9 days. The lorazepam group, however, showed no improvement in these two tests from pre-treatment to 2 days; a significant improvement only emerged between the 2-day and 9-day assessments. This might reflect an initial, transient sedation in the lorazepam-treated patients. 5 Generally, we failed to demonstrate any consistent impairment in psychomotor performance with either clobazam or lorazepam in our anxious patients. These findings contrast with those obtained after administration of 1,4-benzodiazepines (e.g., lorazepam) to normal volunteers and they suggest that data from the latter cannot necessarily be extrapolated to anxious patients. PMID:6136292
Manufacture and performance of carbon/epoxy 3-D woven composites
NASA Technical Reports Server (NTRS)
Brandt, J.; Drechsler, K.; Mohamed, Mansour; Gu, PU
1992-01-01
This paper evaluates 3-D orthogonal woven carbon/epoxy composites. Preforms were manufactured on an automatic 3-D weaving machine developed at N.C. State University. Matrix infiltration was conducted at MBB Central Laboratories. Testing was carried out at both locations and the joint results will be reported. The properties investigated include: interlaminar shear strength, compression, compression after impact, bending, tensile and penetration resistance. The 3-D orthogonal woven composites were compared with laminated and other 3-D composites made with preforms having interlock structure. C-scans were used to examine the quality of infiltration and the damage area after impact. The performance of the composites made from the 3-D orthogonal preforms showed superior properties compared to the other composites. The penetration resistance test showed unexpectedly very good performance.
Performance of RASS vortex detection/measurement system
DOT National Transportation Integrated Search
1999-06-01
Preliminary tests conducted by WLR Research in the Fall of 1993 showed considerable promise that a Radio Acoustic Sounding System (RASS) was capable of detecting and tracking wake vortices located in the approach glide slope. Initial testing of the R...
Telemetry Tests Of The Advanced Receiver II
NASA Technical Reports Server (NTRS)
Hinedi, Sami M.; Bevan, Roland P.; Marina, Miguel
1993-01-01
Report describes telemetry tests of Advanced Receiver II (ARX-II): digital radio receiving subsystem operating on intermediate-frequency output of another receiving subsystem called "multimission receiver" (MMR), detecting carrier, subcarrier, and data-symbol signals transmitted by spacecraft, and extracts Doppler information from signals. Analysis of data shows performance of MMR/ARX-II system comparable and sometimes superior to performances of Blk-III/BPA and Blk-III/SDA/SSA systems.
NASA Astrophysics Data System (ADS)
Destic, F.; Petitjean, Y.; Massenot, S.; Mollier, J.-C.; Barbieri, S.
2010-08-01
This paper presents a CW raster-scanning THz imaging setup, used to perform Non-Destructive Testing of KevlarTMand carbon fibre samples. The setup uses a 2.5 THz Quantum Cascade Laser as a source. Delamination defect in a Kevlar sample was detected showing a sensitivity to laser polarization orientation. Detection of a break in a carbon/epoxy sample was also performed.
ERIC Educational Resources Information Center
Bertoni, Marco; Brunello, Giorgio; Rocco, Lorenzo
2013-01-01
We use a natural experiment to show that the presence of an external examiner has both a direct and an indirect negative effect on the performance of monitored classes in standardized educational tests. The direct effect is the difference in the test performance between classes of the same school with and without external examiners. The indirect…
Panasonic Small Cell Testing for AHPS
NASA Technical Reports Server (NTRS)
Pearson, C.; Blackmore, P.; Lain, M.; Walpole, A.; Darcy, Eric
2006-01-01
AEA selection and successful Interim Design Review for AHPS proves maturity of small cell approach for very large batteries. Cells show excellent opportunity for battery mass reduction for AHPS and other low cycle applications. Lack of cycle and extended calendar life make EOL battery performance difficult (AHPS 8 year mission). Preliminary design, AEA retained SONY 18650HC cell as baseline: a) Well characterized performance; b) Wealth of safety test data.
Affective temperament and executive functions in emergency medicine professionals.
Jaracz, Marcin; Paciorek, Przemysław; Buciński, Adam; Borkowska, Alina
2014-10-01
Recent studies indicate that choice of profession is related to differences in affective temperament, which is probably due to various predispositions needed to efficiently perform particular professions. The aim of the present study was to assess affective temperament and executive functions in a sample of emergency medicine professionals. 75 emergency medicine professionals were enrolled in the study. Affective temperament was assessed by means of TEMPS-A. Executive functions were assessed by means of Trail Making Test and Stroop Color Word Interference Test. Subjects showed significantly higher rates of hyperthymic, compared to depressive, cyclothymic, irritable and anxious temperaments. The principal component analysis revealed that hyperthymic temperament contributes to a different factor, than the remaining ones. Higher rates of depressive, cyclothymic, irritable and anxious temperaments were related to poorer performance in Trail Making Test, whereas hyperthymic temperament had the opposite effect. Due to the size of the sample, results of the present study may have lacked power to show all the relationships between tested variables. Hyperthymic temperament promotes efficient performance of complex tasks under time pressure. Depressive, cyclothymic, irritable and anxious temperaments have the opposite effect. This makes hyperthymic temperament a desirable trait in emergency medicine professionals, performing complex medical tasks under extreme conditions. Copyright © 2014 Elsevier B.V. All rights reserved.
Humbert, H; Machinal, C; Labaye, Ivan; Schrotter, J C
2011-01-01
The determination of the virus retention capabilities of UF units during operation is essential for the operators of drinking water treatment facilities in order to guarantee an efficient and stable removal of viruses through time. In previous studies, an effective method (MS2-phage challenge tests) was developed by the Water Research Center of Veolia Environnement for the measurement of the virus retention rates (Log Removal Rate, LRV) of commercially available hollow fiber membranes at lab scale. In the present work, the protocol for monitoring membrane performance was transferred from lab scale to pilot scale. Membrane performances were evaluated during pilot trial and compared to the results obtained at lab scale with fibers taken from the pilot plant modules. PFU culture method was compared to RT-PCR method for the calculation of LRV in both cases. Preliminary tests at lab scale showed that both methods can be used interchangeably. For tests conducted on virgin membrane, a good consistency was observed between lab and pilot scale results with the two analytical methods used. This work intends to show that a reliable determination of the membranes performances based on RT-PCR analytical method can be achieved during the operation of the UF units.
The effects of ethosuximide on aversive instrumental learning in adult rats.
Orczyk, John J; Garraghty, Preston E
2018-05-03
Antiepileptic medications are the frontline treatment for seizure conditions but are not without cognitive side effects. Previously, our laboratory reported learning deficits in phenytoin-, carbamazepine-, valproic acid-, and felbamate-treated rats. In this experiment, the effects found in ethosuximide (ETH)-treated rats have been compared with those in water-treated controls (controls) using the same instrumental training tasks. Rats treated with ETH did not display any performance deficits in any of the conditions tested relative to controls. These animals showed more rapid acquisition of the avoidance response than the control animals but only when they had prior experience in the appetitive condition. Of the drugs tested to date with these learning paradigms, ETH is the only one that did not impair performance relative to controls in any condition tested. Moreover, in comparison with rats treated with valproic acid, the only other available compound commonly recommended for the treatment of absence seizures, ETH-treated rats show substantially higher performance. Copyright © 2018 Elsevier Inc. All rights reserved.
Predicting space telerobotic operator training performance from human spatial ability assessment
NASA Astrophysics Data System (ADS)
Liu, Andrew M.; Oman, Charles M.; Galvan, Raquel; Natapoff, Alan
2013-11-01
Our goal was to determine whether existing tests of spatial ability can predict an astronaut's qualification test performance after robotic training. Because training astronauts to be qualified robotics operators is so long and expensive, NASA is interested in tools that can predict robotics performance before training begins. Currently, the Astronaut Office does not have a validated tool to predict robotics ability as part of its astronaut selection or training process. Commonly used tests of human spatial ability may provide such a tool to predict robotics ability. We tested the spatial ability of 50 active astronauts who had completed at least one robotics training course, then used logistic regression models to analyze the correlation between spatial ability test scores and the astronauts' performance in their evaluation test at the end of the training course. The fit of the logistic function to our data is statistically significant for several spatial tests. However, the prediction performance of the logistic model depends on the criterion threshold assumed. To clarify the critical selection issues, we show how the probability of correct classification vs. misclassification varies as a function of the mental rotation test criterion level. Since the costs of misclassification are low, the logistic models of spatial ability and robotic performance are reliable enough only to be used to customize regular and remedial training. We suggest several changes in tracking performance throughout robotics training that could improve the range and reliability of predictive models.
Integration Test of the High Voltage Hall Accelerator System Components
NASA Technical Reports Server (NTRS)
Kamhawi, Hani; Haag, Thomas; Huang, Wensheng; Pinero, Luis; Peterson, Todd; Dankanich, John
2013-01-01
NASA Glenn Research Center is developing a 4 kilowatt-class Hall propulsion system for implementation in NASA science missions. NASA science mission performance analysis was completed using the latest high voltage Hall accelerator (HiVHAc) and Aerojet-Rocketdyne's state-of-the-art BPT-4000 Hall thruster performance curves. Mission analysis results indicated that the HiVHAc thruster out performs the BPT-4000 thruster for all but one of the missions studied. Tests of the HiVHAc system major components were performed. Performance evaluation of the HiVHAc thruster at NASA Glenn's vacuum facility 5 indicated that thruster performance was lower than performance levels attained during tests in vacuum facility 12 due to the lower background pressures attained during vacuum facility 5 tests when compared to vacuum facility 12. Voltage-Current characterization of the HiVHAc thruster in vacuum facility 5 showed that the HiVHAc thruster can operate stably for a wide range of anode flow rates for discharge voltages between 250 and 600 volts. A Colorado Power Electronics enhanced brassboard power processing unit was tested in vacuum for 1,500 hours and the unit demonstrated discharge module efficiency of 96.3% at 3.9 kilowatts and 650 volts. Stand-alone open and closed loop tests of a VACCO TRL 6 xenon flow control module were also performed. An integrated test of the HiVHAc thruster, brassboard power processing unit, and xenon flow control module was performed and confirmed that integrated operation of the HiVHAc system major components. Future plans include continuing the maturation of the HiVHAc system major components and the performance of a single-string integration test.
Ruiz, Diego M; Autino, Juan C; Quaranta, Nancy; Vázquez, Patricia G; Romanelli, Gustavo P
2012-01-01
We report a suitable quinoxaline synthesis using molybdophosphovanadates supported on commercial alumina cylinders as catalysts. These catalysts were prepared by incipient wetness impregnation. The catalytic test was performed under different reaction conditions in order to know the performance of the synthesized catalysts. The method shows high yields of quinoxaline derivatives under heterogeneous conditions. Quinoxaline formation was obtained using benzyl, o-phenylenediamine, and toluene as reaction solvent at room temperature. The CuH(2)PMo(11)VO(40) supported on alumina showed higher activity in the tested reaction. Finally, various quinoxalines were prepared under mild conditions and with excellent yields.
Generation 1.5 High Speed Civil Transport (HSCT) Exhaust Nozzle Program
NASA Technical Reports Server (NTRS)
Thayer, E. B.; Gamble, E. J.; Guthrie, A. R.; Kehret, D. F.; Barber, T. J.; Hendricks, G. J.; Nagaraja, K. S.; Minardi, J. E.
2004-01-01
The objective of this program was to conduct an experimental and analytical evaluation of low noise exhaust nozzles suitable for future High-Speed Civil Transport (HSCT) aircraft. The experimental portion of the program involved parametric subscale performance model tests of mixer/ejector nozzles in the takeoff mode, and high-speed tests of mixer/ejectors converted to two-dimensional convergent-divergent (2-D/C-D), plug, and single expansion ramp nozzles (SERN) in the cruise mode. Mixer/ejector results show measured static thrust coefficients at secondary flow entrainment levels of 70 percent of primary flow. Results of the high-speed performance tests showed that relatively long, straight-wall, C-D nozzles could meet supersonic cruise thrust coefficient goal of 0.982; but the plug, ramp, and shorter C-D nozzles required isentropic contours to reach the same level of performance. The computational fluid dynamic (CFD) study accurately predicted mixer/ejector pressure distributions and shock locations. Heat transfer studies showed that a combination of insulation and convective cooling was more effective than film cooling for nonafterburning, low-noise nozzles. The thrust augmentation study indicated potential benefits for use of ejector nozzles in the subsonic cruise mode if the ejector inlet contains a sonic throat plane.
Maximal and submaximal endurance performance in adults with severe haemophilia.
Herbsleb, M; Hilberg, T
2009-01-01
Maximal exercise testing, including the determination of maximal performance and maximal oxygen uptake (VO(2max)), is considered the gold standard for assessing maximal endurance performance. The effectiveness of such testing is often reduced in haemophilic adults owing to musculoskeletal impairments or pain rather than because of cardiac exertion. The measurement of submaximal performance parameters overcomes many limitations of maximal exercise testing but a testing standard is still lacking. The aim of this study was to investigate maximal and particularly submaximal endurance performance of adult patients with severe haemophilia A and B. Eleven patients and 11 matched healthy controls were tested by spiroergometry with a specific treadmill test and the power was calculated in Watts. The haemophilic group achieved lower absolute (210 +/- 63 W) and weight-related (2.94 +/- 0.98 W kg(-1)) maximal endurance performance compared with the control group (287 +/- 50 W resp. 3.82 +/- 0.53 W kg(-1); P = 0.05). The patients also showed a lower submaximal endurance performance at the individual anaerobic threshold (IAT = 147 +/- 56 W) and fixed lactate values (2 mmol = 98 +/- 60 W; 4 mmol = 158 +/- 56 W) compared with the healthy controls (IAT = 210 +/- 41 W; 2 mmol = 153 +/- 30 W; 4 mmol = 223 +/- 39 W; all P = 0.05). The heart rate and lactate value at the IAT were not different. The disease-related musculoskeletal changes in haemophilic adults lead to a reduced maximal and submaximal endurance performance, which can be easily measured by the described test procedure.
Kurtz, Matthew M; Wexler, Bruce E
2006-01-31
The aim of this study was two-fold: 1) to determine whether a priori subtyping of patients with schizophrenia based on both overall performance on a measure of executive-function, the Wisconsin Card Sorting Test (WCST), and ability to learn the task with expanded instruction, could be confirmed with other, independent measures of executive-function and learning, and, if so, 2) to determine whether these groups have different neurocognitive profiles and show differences in functional capacity. Fifty-four outpatients with schizophrenia were divided by WCST performance into three groups: intact executive-function (n=28), "good learner" (n=13), and "poor learner" (n=13) groups. These groups were then assessed with a comprehensive neurocognitive test battery and a performance-based measure of functional status, the UCSD Performance-based Skills Assessment (UPSA). The WCST-intact subgroup performed significantly better than other groups on a second measure of executive-function and in working memory, and speeded motor sequencing. Impaired WCST patients who benefited from expanded WCST instruction ("good learners") also showed better performance than patients who did not benefit from instruction ("poor-learners") on a second measure of learning, as well as on a measure of auditory divided attention. The intact WCST subgroup had greater functional capacity than either "strong" or "poor" learners. These subtypes may have implications for response to behavioral treatment interventions.
Thermal Performance Testing of Order Dependancy of Aerogels Multilayered Insulation
NASA Technical Reports Server (NTRS)
Johnson, Wesley L.; Fesmire, James E.; Demko, J. A.
2009-01-01
Robust multilayer insulation systems have long been a goal of many research projects. Such insulation systems must provide some degree of structural support and also mechanical integrity during loss of vacuum scenarios while continuing to provide insulative value to the vessel. Aerogel composite blankets can be the best insulation materials in ambient pressure environments; in high vacuum, the thermal performance of aerogel improves by about one order of magnitude. Standard multilayer insulation (MU) is typically 50% worse at ambient pressure and at soft vacuum, but as much as two or three orders of magnitude better at high vacuum. Different combinations of aerogel and multilayer insulation systems have been tested at Cryogenics Test Laboratory of NASA Kennedy Space Center. Analysis performed at Oak Ridge National Laboratory showed an importance to the relative location of the MU and aerogel blankets. Apparent thermal conductivity testing under cryogenic-vacuum conditions was performed to verify the analytical conclusion. Tests results are shown to be in agreement with the analysis which indicated that the best performance is obtained with aerogel layers located in the middle of the blanket insulation system.
Thermal Performance of Low Layer Density Multilayer Insu1ation Using Liquid Nitrogen
NASA Technical Reports Server (NTRS)
Johnson, Wesley L.; Fesmire, James E.
2011-01-01
In order to support long duration cryogenic propellant storage, the Cryogenic Fluid Management (CFM) Project of the Exploration Technology Development Program (ETDP) is investigating the long duration storage propertie$ of liquid methane on the lunar surface. The Methane Lunar Surface Thermal Control (MLSTC) testing is using a tank of the approximate dimensions of the Altair ascent tanks inside of a vacuum chamber to simulate the environment in low earth orbit and on the lunar surface. The thermal performance testing of multilayer insulation (MLI) coupons that are fabricated identically to the tank applied insulation is necessary to understand the performance of the blankets and to be able to predict the performance of the insulation prior to testing. This coupon testing was completed in Cryostat-100 at the Cryogenics Test Laboratory. The results showed the properties of the insulation as a function of layer density, number of layers, and warm boundary temperature. These results aid in the understanding of the performance parameters o fMLI and help to complete the body of literature on the topic.
NASA Technical Reports Server (NTRS)
McClinton, C.; Rondakov, A.; Semenov, V.; Kopehenov, V.
1991-01-01
NASA has contracted with the Central Institute of Aviation Motors CIAM to perform a flight test and ground test and provide a scramjet engine for ground test in the United States. The objective of this contract is to obtain ground to flight correlation for a supersonic combustion ramjet (scramjet) engine operating point at a Mach number of 6.5. This paper presents results from a flow path performance and thermal evaluation performed on the design proposed by the CIAM. This study shows that the engine will perform in the scramjet mode for stoichiometric operation at a flight Mach number of 6.5. Thermal assessment of the structure indicates that the combustor cooling liner will provide adequate cooling for a Mach number of 6.5 test condition and that optional material proposed by CIAM for the cowl leading-edge design are required to allow operation with or without a type IV shock-shock interaction.
NASA Astrophysics Data System (ADS)
Bijl, Piet
2016-10-01
When acquiring a new imaging system and operational task performance is a critical factor for success, it is necessary to specify minimum acceptance requirements that need to be met using a sensor performance model and/or performance tests. Currently, there exist a variety of models and test from different origin (defense, security, road safety, optometry) and they all do different predictions. This study reviews a number of frequently used methods and shows the effects that small changes in procedure or threshold criteria can have on the outcome of a test. For example, a system may meet the acceptance requirements but not satisfy the needs for the operational task, or the choice of test may determine the rank order of candidate sensors. The goal of the paper is to make people aware of the pitfalls associated with the acquisition process, by i) illustrating potential tricks to have a system accepted that is actually not suited for the operational task, and ii) providing tips to avoid this unwanted situation.
Richter, Kim Merle; Mödden, Claudia; Eling, Paul; Hildebrandt, Helmut
2018-04-26
To show the effectiveness of a combined recognition and working memory training on everyday memory performance in patients suffering from organic memory disorders. In this double-blind, randomized controlled Study 36 patients with organic memory impairments, mainly attributable to stroke, were assigned to either the experimental or the active control group. In the experimental group a working memory training was combined with a recollection training based on the repetition-lag procedure. Patients in the active control group received the memory therapy usually provided in the rehabilitation center. Both groups received nine hours of therapy. Prior (T0) and subsequent (T1) to the therapy, patients were evaluated on an everyday memory test (EMT) as well as on a neuropsychological test battery. Based on factor analysis of the neuropsychological test scores at T0 we calculated composite scores for working memory, verbal learning and word fluency. After treatment, the intervention group showed a significantly greater improvement for WM performance compared with the active control group. More importantly, performance on the EMT also improved significantly in patients receiving the recollection and working memory training compared with patients with standard memory training. Our results show that combining working memory and recollection training significantly improves performance on everyday memory tasks, demonstrating far transfer effects. The present study argues in favor of a process-based approach for treating memory impairments. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Custodio, Nilton; Montesinos, Rosa; Lira, David; Herrera-Perez, Eder; Bardales, Yadira; Valeriano-Lorenzo, Lucia
2017-01-01
ABSTRACT. There is limited evidence about the progression of cognitive performance during the post-stroke stage. Objective: To assess the evolution of cognitive performance in stroke patients without vascular cognitive impairment (VCI), patients with vascular mild cognitive impairment (MCI), and patients with vascular dementia (VD). Methods: A prospective cohort of stroke outpatients from two secondary medical centers in Lima, Peru was studied. We performed standardized evaluations at definitive diagnosis (baseline evaluation), and control follow-ups at 6 and 12 months, including a battery of short cognitive tests: Clinical Dementia Rating (CDR), Addenbrooke's Cognitive Examination (ACE), and INECO Frontal Screening (IFS). Results: 152 outpatients completed the follow-up, showing progressive increase in mean score on the CDR(0.34 to 0.46), contrary to the pattern observed on the ACE and IFS (78.18 to 76.48 and 23.63 to 22.24). The box plot for the CDR test showed that VCI patients had progressive worsening (0.79 to 0.16). Conversely, this trend was not observed in subjects without VCI. The box plot for the ACE and IFS showed that, for the majority of the differentiated stroke types, both non-VCI and VCI patients had progressive worsening. Conclusion: According to both ACE and IFS results during a 1-year follow-up, the cognitive performance of stroke patients worsened, a trend which was particularly consistent in infarction-type stroke patients. PMID:29354218
Cognitive deficits are associated with poorer simulated driving in older adults with heart failure
2013-01-01
Background Cognitive impairment is prevalent in older adults with heart failure (HF) and associated with reduced functional independence. HF patients appear at risk for reduced driving ability, as past work in other medical samples has shown cognitive dysfunction to be an important contributor to driving performance. The current study examined whether cognitive dysfunction was independently associated with reduced driving simulation performance in a sample of HF patients. Methods 18 persons with HF (67.72; SD = 8.56 year) completed echocardiogram and a brief neuropsychological test battery assessing global cognitive function, attention/executive function, memory and motor function. All participants then completed the Kent Multidimensional Assessment Driving Simulation (K-MADS), a driving simulator scenario with good psychometric properties. Results The sample exhibited an average Mini Mental State Examination (MMSE) score of 27.83 (SD = 2.09). Independent sample t-tests showed that HF patients performed worse than healthy adults on the driving simulation scenario. Finally, partial correlations showed worse attention/executive and motor function were independently associated with poorer driving simulation performance across several indices reflective of driving ability (i.e., centerline crossings, number of collisions, % of time over the speed limit, among others). Conclusion The current findings showed that reduced cognitive function was associated with poor simulated driving performance in older adults with HF. If replicated using behind-the-wheel testing, HF patients may be at elevated risk for unsafe driving and routine driving evaluations in this population may be warranted. PMID:24499466
Fatigue Index and Fatigue Rate during an Anaerobic Performance under Hypohydrations
Naharudin, Mohamed Nashrudin; Yusof, Ashril
2013-01-01
Background Since hypohydration commonly occurs in sports, studies on anaerobic exercise performance under this condition have been extensively carried out. When describing anaerobic performance, authors usually refer to a drop in anaerobic performance as fatigue index (FI) which is conventionally calculated using peak and low power data points. Meanwhile, another possible method in explaining anaerobic fatigue is using the rate constant which is derived from the exponential decline of power output known as fatigue rate (FR). Few studies have demonstrated that there was no change in anaerobic performance under mild hypohydrations. Purpose This study aimed to compare the kinetics of power output using FI and FR of an anaerobic performance (Wingate test) under 2, 3 and 4% state of hypohydrations. Method Thirty two collegiate cyclists (age = 22±2 years; body weight = 71.45±3.43 kg; height = 173.23±0.04 cm) were matched using their baseline anaerobic peak power (APP) then randomly divided into 4 groups of EU (euhydrated), 2H, 3H and 4H respectively. Results As expected the, FI, APP, anaerobic lower power (ALP) and rating of perceived exertion (RPE) did not show significant differences between and within the groups. However, the FR in 3H (0.018±0.005s−1) and 4H (0.019±0.010s−1) were significantly lower than EU (0.033±0.012s−1). Post-test FR also showed significant reduction in 3H and 4H compared to their pre-test values (p<0.05). Conclusion Despite the lack of changes in APP and RPE, subjects in 3H and 4H showed evidence of lower reduction of power output over time. The findings support earlier reports which showed no change in anaerobic performance under mild hypohydrations. The relatively lower FR suggests higher drive in maintaining power output under hypohydrations of 3 and 4% body weight. PMID:24204790
High temperature fuel/emitter system for advanced thermionic fuel elements
NASA Astrophysics Data System (ADS)
Moeller, Helen H.; Bremser, Albert H.; Gontar, Alexander; Fiviesky, Evgeny
1997-01-01
Specialists in space applications are currently focusing on bimodal power systems designed to provide both electric power and thermal propulsion (Kennedy, 1994 and Houts, 1995). Our work showed that thermionics is a viable technology for nuclear bimodal power systems. We demonstrated that materials for a thermionic fuel-emitter combination capable of performing at operating temperatures of 2473 K are not only possible but available. The objective of this work, funded by the US Department of Energy, Office of Space and Defense Power Systems, was to evaluate the compatibility of fuel material consisting of an uranium carbide/tantalum carbide solid solution with an emitter material consisting of a monocrystalline tungsten-niobium alloy. The uranium loading of the fuel material was 70 mole% uranium carbide. The program was successfully accomplished by a B&W/SIA LUTCH team. Its workscope was integrated with tasks being performed at both Babcock & Wilcox, Lynchburg Research Center, Lynchburg, Virginia, and SIA LUTCH, Podolsk, Russia. Samples were fabricated by LUTCH and seven thermal tests were performed in a hydrogen atmosphere. The first preliminary test was performed at 2273 K by LUTCH, and the remaining six tests were performed At B&W. Three tests were performed at 2273 K, two at 2373 K, and the final test at 2473 K. The results showed that the fuel and emitter materials were compatible in the presence of hydrogen. No evidence of liquid formation, dissolution of the uranium carbide from the uranium carbide/tantalum carbide solid solution, or diffusion of the uranium into the monocrystalline tungsten alloy was observed. Among the highlights of the program was the successful export of the fuel samples from Russia and their import into the US by commercial transport. This paper will discuss the technical aspects of this work.
Engineering characterisation of epoxidized natural rubber-modified hot-mix asphalt
Al-Mansob, Ramez A.; Ismail, Amiruddin; Yusoff, Nur Izzi Md.; Rahmat, Riza Atiq O. K.; Borhan, Muhamad Nazri; Albrka, Shaban Ismael; Azhari, Che Husna; Karim, Mohamed Rehan
2017-01-01
Road distress results in high maintenance costs. However, increased understandings of asphalt behaviour and properties coupled with technological developments have allowed paving technologists to examine the benefits of introducing additives and modifiers. As a result, polymers have become extremely popular as modifiers to improve the performance of the asphalt mix. This study investigates the performance characteristics of epoxidized natural rubber (ENR)-modified hot-mix asphalt. Tests were conducted using ENR–asphalt mixes prepared using the wet process. Mechanical testing on the ENR–asphalt mixes showed that the resilient modulus of the mixes was greatly affected by testing temperature and frequency. On the other hand, although rutting performance decreased at high temperatures because of the increased elasticity of the ENR–asphalt mixes, fatigue performance improved at intermediate temperatures as compared to the base mix. However, durability tests indicated that the ENR–asphalt mixes were slightly susceptible to the presence of moisture. In conclusion, the performance of asphalt pavement can be enhanced by incorporating ENR as a modifier to counter major road distress. PMID:28182724
Apperly, Ian A; Samson, Dana; Chiavarino, Claudia; Bickerton, Wai-Ling; Humphreys, Glyn W
2007-05-01
To test the domain-specificity of "theory of mind" abilities we compared the performance of a case-series of 11 brain-lesioned patients on a recently developed test of false belief reasoning () and on a matched false photograph task, which did not require belief reasoning and which addressed problems with existing false photograph methods. A strikingly similar pattern of performance was shown across the false belief and false photograph tests. Patients who were selectively impaired on false belief tasks were also impaired on false photograph tasks; patients spared on false belief tasks also showed preserved performance with false photographs. In some cases the impairment on false belief and false photograph tasks coincided with good performance on control tasks matched for executive demands. We discuss whether the patients have a domain-specific deficit in reasoning about representations common to both false belief and false photograph tasks.
NASA Technical Reports Server (NTRS)
Ewashinka, J. G.; Bozek, J. M.
1981-01-01
A state-of-the-art 6-V battery module in current use by the electric vehicle industry was tested at the NASA Lewis Research Center to determine its performance characteristics under the SAE J227a driving schedules B, C, and D. The primary objective of the tests was to determine the effects of periods of recuperation and long and short periods of electrical regeneration in improving the performance of the battery module and hence extendng the vehicle range. A secondary objective was to formulate a computer program that would predict the performance of this battery module for the above driving schedules. The results show excellent correlation between the laboratory tests and predicted results. The predicted performance compared with laboratory tests was within +2.4 to -3.7 percent for the D schedule, +0.5 to -7.1 percent for the C schedule, and better than -11.4 percent for the B schedule.
Engineering characterisation of epoxidized natural rubber-modified hot-mix asphalt.
Al-Mansob, Ramez A; Ismail, Amiruddin; Yusoff, Nur Izzi Md; Rahmat, Riza Atiq O K; Borhan, Muhamad Nazri; Albrka, Shaban Ismael; Azhari, Che Husna; Karim, Mohamed Rehan
2017-01-01
Road distress results in high maintenance costs. However, increased understandings of asphalt behaviour and properties coupled with technological developments have allowed paving technologists to examine the benefits of introducing additives and modifiers. As a result, polymers have become extremely popular as modifiers to improve the performance of the asphalt mix. This study investigates the performance characteristics of epoxidized natural rubber (ENR)-modified hot-mix asphalt. Tests were conducted using ENR-asphalt mixes prepared using the wet process. Mechanical testing on the ENR-asphalt mixes showed that the resilient modulus of the mixes was greatly affected by testing temperature and frequency. On the other hand, although rutting performance decreased at high temperatures because of the increased elasticity of the ENR-asphalt mixes, fatigue performance improved at intermediate temperatures as compared to the base mix. However, durability tests indicated that the ENR-asphalt mixes were slightly susceptible to the presence of moisture. In conclusion, the performance of asphalt pavement can be enhanced by incorporating ENR as a modifier to counter major road distress.
NASA Astrophysics Data System (ADS)
Ewashinka, J. G.; Bozek, J. M.
1981-05-01
A state-of-the-art 6-V battery module in current use by the electric vehicle industry was tested at the NASA Lewis Research Center to determine its performance characteristics under the SAE J227a driving schedules B, C, and D. The primary objective of the tests was to determine the effects of periods of recuperation and long and short periods of electrical regeneration in improving the performance of the battery module and hence extendng the vehicle range. A secondary objective was to formulate a computer program that would predict the performance of this battery module for the above driving schedules. The results show excellent correlation between the laboratory tests and predicted results. The predicted performance compared with laboratory tests was within +2.4 to -3.7 percent for the D schedule, +0.5 to -7.1 percent for the C schedule, and better than -11.4 percent for the B schedule.
Tsai, Chia-Liang; Pai, Ming-Chyi; Ukropec, Jozef; Ukropcová, Barbara
2016-04-23
Although elderly people with amnestic mild cognitive impairment (aMCI) have been found to show impaired behavioral performance in task switching, no research has yet explored the electrophysiological mechanisms and the potential correlation between physical fitness and neurocognitive (i.e., behavioral and electrophysiological) performance in aMCI. The present study was thus aimed to examine whether there are differences in electrophysiological (i.e., event-related potential) performance between aMCI participants and controls when performing a task-switching paradigm, and to investigate the role of physical fitness in the relationship between neurocognitive performance and aMCI. Sixty participants were classified into aMCI (n = 30) and control (n = 30) groups, and performed a task-switching paradigm with concomitant electrophysiological recording, as well as underwent senior functional physical fitness tests. The aMCI group showed comparable scores on most parts of the physical fitness tests, but reduced lower body flexibility and VO2max as compared to the control group. When performing the task-switching paradigm, the aMCI group showed slower reaction times in the heterogeneous condition and larger global switching costs, although no significant difference was observed in accuracy rates between the two groups. In addition, the aMCI group showed significantly prolonged P3 latencies in the homogeneous and heterogeneous conditions, and a smaller P3 amplitude only in the heterogeneous condition. The level of cardiorespiratory fitness was significantly correlated with P3 amplitude in the aMCI group, particularly in the heterogeneous condition of the task-switching paradigm. These results show that the aMCI group exhibited abnormalities in their neurocognitive performance when performing the task-switching paradigm and such a deficit was likely associated with reduced cardiorespiratory fitness, which was shown to be the important predictor of neurocognitive performance.
Studies of thermionic materials for space power applications
NASA Technical Reports Server (NTRS)
1971-01-01
Service life tests of LC-8 and LC-9 carbide-fueled thermionic converters are discussed. Post operational tests of the converters to show emitter diametric change, microstructures of cladding and fuel, and analysis of fuel composition are described. The fabrication and performance of high temperature thermocouples used in the test procedures are included.
Optimal Stratification of Item Pools in a-Stratified Computerized Adaptive Testing.
ERIC Educational Resources Information Center
Chang, Hua-Hua; van der Linden, Wim J.
2003-01-01
Developed a method based on 0-1 linear programming to stratify an item pool optimally for use in alpha-stratified adaptive testing. Applied the method to a previous item pool from the computerized adaptive test of the Graduate Record Examinations. Results show the new method performs well in practical situations. (SLD)
Validity and reliability of a new tool to evaluate handwriting difficulties in Parkinson's disease.
Nackaerts, Evelien; Heremans, Elke; Smits-Engelsman, Bouwien C M; Broeder, Sanne; Vandenberghe, Wim; Bergmans, Bruno; Nieuwboer, Alice
2017-01-01
Handwriting in Parkinson's disease (PD) features specific abnormalities which are difficult to assess in clinical practice since no specific tool for evaluation of spontaneous movement is currently available. This study aims to validate the 'Systematic Screening of Handwriting Difficulties' (SOS-test) in patients with PD. Handwriting performance of 87 patients and 26 healthy age-matched controls was examined using the SOS-test. Sixty-seven patients were tested a second time within a period of one month. Participants were asked to copy as much as possible of a text within 5 minutes with the instruction to write as neatly and quickly as in daily life. Writing speed (letters in 5 minutes), size (mm) and quality of handwriting were compared. Correlation analysis was performed between SOS outcomes and other fine motor skill measurements and disease characteristics. Intrarater, interrater and test-retest reliability were assessed using the intraclass correlation coefficient (ICC) and Spearman correlation coefficient. Patients with PD had a smaller (p = 0.043) and slower (p<0.001) handwriting and showed worse writing quality (p = 0.031) compared to controls. The outcomes of the SOS-test significantly correlated with fine motor skill performance and disease duration and severity. Furthermore, the test showed excellent intrarater, interrater and test-retest reliability (ICC > 0.769 for both groups). The SOS-test is a short and effective tool to detect handwriting problems in PD with excellent reliability. It can therefore be recommended as a clinical instrument for standardized screening of handwriting deficits in PD.
Sukenik, Nufar; Friedmann, Naama
2018-01-01
Do individuals with autism have a developmental syntactic impairment, DLI (formerly known as SLI)? In this study we directly compared the performance of 18 individuals with Autism Spectrum Disorder (ASD) aged 9;0-18;0 years with that of 93 individuals with Syntactic-Developmental Language Impairment (SyDLI) aged 8;8-14;6 (and with 166 typically-developing children aged 5;2-18;1). We tested them using three syntactic tests assessing the comprehension and production of syntactic structures that are known to be sensitive to syntactic impairment: elicitation of subject and object relative clauses, reading and paraphrasing of object relatives, and repetition of complex syntactic structures including Wh questions, relative clauses, topicalized sentences, sentences with verb movement, sentences with A-movement, and embedded sentences. The results were consistent across the three tasks: the overall rate of correct performance on the syntactic tasks is similar for the children with ASD and those with SyDLI. However, once we look closer, they are very different. The types of errors of the ASD group differ from those of the SyDLI group-the children with ASD provide various types of pragmatically infelicitous responses that are not evinced in the SyDLI or in the age equivalent typically-developing groups. The two groups (ASD and SyDLI) also differ in the pattern of performance-the children with SyDLI show a syntactically-principled pattern of impairment, with selective difficulty in specific sentence types (such as sentences derived by movement of the object across the subject), and normal performance on other structures (such as simple sentences). In contrast, the ASD participants showed generalized low performance on the various sentence structures. Syntactic performance was far from consistent within the ASD group. Whereas all ASD participants had errors that can originate in pragmatic/discourse difficulties, seven of them had completely normal syntax in the structures we tested, and were able to produce, understand, and repeat relative clauses, Wh questions, and topicalized sentences. Only one ASD participant showed a syntactically-principled deficit similar to that of individuals with SyDLI. We conclude that not all individuals with ASD have syntactic difficulties, and that even when they fail in a syntactic task, this does not necessarily originate in a syntactic impairment. This shows that looking only at the total score in a syntactic test may be insufficient, and a fuller picture emerges once the performance on different structures and the types of erroneous responses are analyzed.
NASA Astrophysics Data System (ADS)
Jamalludin, Mohd Riduan; Harun, Zawati; Zakaria, M. S.; Rahim, Wan Mohd Faizal Wan Abd; Khor, C. Y.; Rosli, M. U.; Ishak, Muhammad Ikman; Nawi, M. A. M.; Shahrin, Suhaimi
2017-09-01
This study investigates the effect of hydrophilicity of graphene oxide as additive towards properties and performance on polysulfone (PSf) membrane. A polysulfone (PSf) membrane containing graphene oxide (GO) with different content was prepared via phase inversion technique. Characterization on the fabricated membrane were water contact angle measurement, porosity and mean pore size. The effects of PSf/GO were further investigated in terms of permeation test, rejection test and antifouling test. Based on the result obtained, PSf membrane incorporating with GO additive shows better capability to permeate more water compared to unfilled PSf membrane. The PSf/GO membrane were able to increase the permeate rate rapidly with the highest value is given by sample 4 (consist of 0.7 g of GO) at 571.78 J/m2h. Furthermore, water contact angle confirmed the hydrophilicity of this membrane at 62°. The transmembrane fouling activity showed that GO embedded in PSf membrane has improved tremendously. In addition, this study revealed that 0.7g of GO had the highest permeation test, rejection test and antifouling test.
Verster, Joris C; Roth, Thomas
2012-03-01
There are various methods to examine driving ability. Comparisons between these methods and their relationship with actual on-road driving is often not determined. The objective of this study was to determine whether laboratory tests measuring driving-related skills could adequately predict on-the-road driving performance during normal traffic. Ninety-six healthy volunteers performed a standardized on-the-road driving test. Subjects were instructed to drive with a constant speed and steady lateral position within the right traffic lane. Standard deviation of lateral position (SDLP), i.e., the weaving of the car, was determined. The subjects also performed a psychometric test battery including the DSST, Sternberg memory scanning test, a tracking test, and a divided attention test. Difference scores from placebo for parameters of the psychometric tests and SDLP were computed and correlated with each other. A stepwise linear regression analysis determined the predictive validity of the laboratory test battery to SDLP. Stepwise regression analyses revealed that the combination of five parameters, hard tracking, tracking and reaction time of the divided attention test, and reaction time and percentage of errors of the Sternberg memory scanning test, together had a predictive validity of 33.4%. The psychometric tests in this test battery showed insufficient predictive validity to replace the on-the-road driving test during normal traffic.
Racinais, Sebastien; Buchheit, Martin; Bilsborough, Johann; Bourdon, Pitre C; Cordy, Justin; Coutts, Aaron J
2014-07-01
To examine the physiological and performance responses to a heat-acclimatization camp in highly trained professional team-sport athletes. Eighteen male Australian Rules Football players trained for 2 wk in hot ambient conditions (31-33°C, humidity 34-50%). Players performed a laboratory-based heat-response test (24-min walk + 24 min seated; 44°C), a YoYo Intermittent Recovery Level 2 Test (YoYoIR2; indoor, temperate environment, 23°C) and standardized training drills (STD; outdoor, hot environment, 32°C) at the beginning and end of the camp. The heat-response test showed partial heat acclimatization (eg, a decrease in skin temperature, heart rate, and sweat sodium concentration, P < .05). In addition, plasma volume (PV, CO rebreathing, +2.68 [0.83; 4.53] mL/kg) and distance covered during both the YoYoIR2 (+311 [260; 361] m) and the STD (+45.6 [13.9; 77.4] m) increased postcamp (P < .01). None of the performance changes showed clear correlations with PV changes (r < .24), but the improvements in running STD distance in hot environment were correlated with changes in hematocrit during the heat-response test (r = -.52, 90%CI [-.77; -.12]). There was no clear correlation between the performance improvements in temperate and hot ambient conditions (r < .26). Running performance in both hot and temperate environments was improved after a football training camp in hot ambient conditions that stimulated heat acclimatization. However, physiological and performance responses were highly individual, and the absence of correlations between physical-performance improvements in hot and temperate environments suggests that their physiological basis might differ.
Neuropsychological Correlates of Hazard Perception in Older Adults.
McInerney, Katalina; Suhr, Julie
2016-03-01
Hazard perception, the ability to identify and react to hazards while driving, is of growing importance in driving research, given its strong relationship to real word driving variables. Furthermore, although poor hazard perception is associated with novice drivers, recent research suggests that it declines with advanced age. In the present study, we examined the neuropsychological correlates of hazard perception in a healthy older adult sample. A total of 68 adults age 60 and older who showed no signs of dementia and were active drivers completed a battery of neuropsychological tests as well as a hazard perception task. Tests included the Repeatable Battery for the Assessment of Neuropsychological Status, Wechsler Test of Adult Reading, Trail Making Test, Block Design, Useful Field of View, and the Delis-Kaplan Executive Function System Color Word Interference Test. Hazard perception errors were related to visuospatial/constructional skills, processing speed, memory, and executive functioning skills, with a battery of tests across these domains accounting for 36.7% of the variance in hazard perception errors. Executive functioning, particularly Trail Making Test part B, emerged as a strong predictor of hazard perception ability. Consistent with prior work showing the relationship of neuropsychological performance to other measures of driving ability, neuropsychological performance was associated with hazard perception skill. Future studies should examine the relationship of neuropsychological changes in adults who are showing driving impairment and/or cognitive changes associated with Mild Cognitive Impairment or dementia.
The performance of cable braids and terminations to lightning induced transients
NASA Technical Reports Server (NTRS)
Crofts, David
1991-01-01
The latest specification detailing the test waveforms for indirect lightning transients as applied to aircraft wiring systems specify very high voltages and currents. Although considerable data exists for measuring cable screen leakage using such methods as surface transfer impedance and bulk cable injection, there is little data on the likely core transient level that is likely to be induced from these threats. In particular, the new Waveform 5 at very high current levels (10 kA) is reputed to cause severe cable damage. A range of representative cables were made with various screen termination techniques and screening levels. These were tested first to determine their relative screening performance and then they were subjected to lightning transient testing to all the specified waveforms. Core voltages were measured for each test. Tests were also performed on bundles with fewer wires to determine the failure criteria with Waveform 5 and these tests also include flat conductor cables. The test showed that correctly terminated cable bundles performed well in all the tests and would provide a high level of protection to the electronic systems. The use of overbraides, provided the individual screens are well terminated, appears to be unnecessary.
Ceramic regenerator systems development program
NASA Technical Reports Server (NTRS)
Cook, J. A.; Fucinari, C. A.; Lingscheit, J. N.; Rahnke, C. J.; Rao, V. D.
1978-01-01
Ceramic regenerator cores are considered that can be used in passenger car gas turbine engines, Stirling engines, and industrial/truck gas turbine engines. Improved materials and design concepts aimed at reducing or eliminating chemical attack were placed on durability tests/in industrial gas turbine engines. A regenerator core made from aluminum silicate shows minimal evidence of chemical attack damage after 7804 hours of engine test at 800 C and another showed little distress after 4983 hours at 982 C. The results obtained in ceramic material screening tests, aerothermodynamic performance tests, stress analysis, cost studies, and material specifications are also included.
Predicting neuropsychological test performance on the basis of temporal orientation.
Ryan, Joseph J; Glass, Laura A; Bartels, Jared M; Bergner, CariAnn M; Paolo, Anthony M
2009-05-01
Temporal orientation is often disrupted in the context of psychiatric or neurological disease; tests assessing this function are included in most mental status examinations. The present study examined the relationship between scores on the Temporal Orientation Scale (TOS) and performance on a battery of tests that assess memory, language, and cognitive functioning in a sample of patients with Alzheimer's disease (N = 55). Pearson-product moment correlations showed that, in all but two instances, the TOS was significantly correlated with each neuropsychological measure, p values < or = .05. Also, severely disoriented (i.e., TOS score < or = -8) patients were consistently 'impaired' on memory tests but not on tests of language and general cognitive functioning.
Adaptation of a modern medium helicopter (Sikorsky S-76) to higher harmonic control
NASA Technical Reports Server (NTRS)
Oleary, J. J.; Kottapalli, S. B. R.; Davis, M. W.
1985-01-01
Sikorsky Aircraft has performed analytical studies, design analyses, and risk reduction tests have been performed for Higher Harmonic Control (HHC) on the S-76. The S-76 is an 8 to 10,000 lb helicopter which cruises at 145 kts. Flight test hardware has been assembled, main servo frequency response tested and upgraded, aircraft control system shake tested and verified, open loop controllers designed and fabricated, closed loop controllers defined and evaluated, and rotors turning ground and flight tests planned for the near future. Open loop analysis shows that about 2 deg of higher harmonic feathering at the blade 75% radius will be required to eliminate 4P vibration in the cockpit.
European Multicenter Study on Analytical Performance of Veris HIV-1 Assay.
Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Hofmann, Jörg; Izopet, Jacques; Kalus, Ulrich; Lombardi, Alessandra; Marcos, Maria Angeles; Mileto, Davide; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel W
2017-07-01
The analytical performance of the Veris HIV-1 assay for use on the new, fully automated Beckman Coulter DxN Veris molecular diagnostics system was evaluated at 10 European virology laboratories. The precision, analytical sensitivity, performance with negative samples, linearity, and performance with HIV-1 groups/subtypes were evaluated. The precision for the 1-ml assay showed a standard deviation (SD) of 0.14 log 10 copies/ml or less and a coefficient of variation (CV) of ≤6.1% for each level tested. The 0.175-ml assay showed an SD of 0.17 log 10 copies/ml or less and a CV of ≤5.2% for each level tested. The analytical sensitivities determined by probit analysis were 19.3 copies/ml for the 1-ml assay and 126 copies/ml for the 0.175-ml assay. The performance with 1,357 negative samples demonstrated 99.2% with not detected results. Linearity using patient samples was shown from 1.54 to 6.93 log 10 copies/ml. The assay performed well, detecting and showing linearity with all HIV-1 genotypes tested. The Veris HIV-1 assay demonstrated analytical performance comparable to that of currently marketed HIV-1 assays. (DxN Veris products are Conformité Européenne [CE]-marked in vitro diagnostic products. The DxN Veris product line has not been submitted to the U.S. FDA and is not available in the U.S. market. The DxN Veris molecular diagnostics system is also known as the Veris MDx molecular diagnostics system and the Veris MDx system.). Copyright © 2017 American Society for Microbiology.
Umeki, Kazumi; Umekita, Kunihiko; Hashikura, Yuuki; Yamamoto, Ikuo; Kubo, Kazuyoshi; Nagatomo, Yasuhiro; Okayama, Akihiko
2017-02-01
Human T-lymphotropic virus type 1 (HTLV-1) has been recognized as a cause of adult T-cell leukemia/lymphoma, HTLV-1-associated myelopathy/tropical spastic paraparesis, and HTLV-1-associated uveitis. HTLV-1 infection is normally detected by screening for HTLV-1 antibodies, and positive samples are confirmed by Western blot (WB). However, WB fails to confirm some samples that were positive for HTLV-1 antibodies on screening. Line immunoassay (LIA) is commonly used in Europe and Brazil, but not in Japan. Therefore, we evaluated the performance of LIA as a method of confirming HTLV-1 antibodies using samples in Japan. LIA was compared with polymerase chain reaction (PCR) and WB using 50 negative and 70 positive samples tested by chemiluminescent enzyme immunoassay (CLEIA) in Miyazaki, Japan, an HTLV-1 endemic area. LIA (INNO-LIA HTLVI/II Score) and WB (Problot HTLV-I) were performed according to the manufacturer's instructions. Real-time PCR for HTLV-1 pX region was performed using DNA derived from white blood cells. The samples that tested negative by real-time PCR were further tested by nested PCR. All 50 CLEIA negative samples were determined to be negative by LIA and PCR. Of the 70 positive samples, 66 tested positive by both of LIA and PCR. Three samples tested negative by LIA and PCR, and the remaining sample (PCR negative) showed non-specific staining in LIA and WB. WB showed more indeterminate results than LIA. Gp21 antibody in LIA demonstrated a high ability to discriminate between positive and negative PCR results. Furthermore, the degree of gp21 antibody reaction by LIA showed correlation with HTLV-1 proviral loads (PVLs). Our results indicate that LIA performs well in confirming HTLV-1 seropositivity by showing a low incidence of indeterminate results and good agreement with PCR using samples in Japan, although the number of samples tested was small. In addition, semi-quantitative antibody titer to gp21 correlated well with HTLV-1 PVLs. Further study including larger samples is necessary to determine the positioning of LIA for HTLV-1 detection in Japan.
Jongen, Stefan; Perrier, Joy; Vuurman, Eric F; Ramaekers, Johannes G; Vermeeren, Annemiek
2015-01-01
To assess drug induced driving impairment, initial screening is needed. However, no consensus has been reached about which initial screening tools have to be used. The present study aims to determine the ability of a battery of psychometric tests to detect performance impairing effects of clinically relevant levels of drowsiness as induced by one night of sleep deprivation. Twenty four healthy volunteers participated in a 2-period crossover study in which the highway driving test was conducted twice: once after normal sleep and once after one night of sleep deprivation. The psychometric tests were conducted on 4 occasions: once after normal sleep (at 11 am) and three times during a single night of sleep deprivation (at 1 am, 5 am, and 11 am). On-the-road driving performance was significantly impaired after sleep deprivation, as measured by an increase in Standard Deviation of Lateral Position (SDLP) of 3.1 cm compared to performance after a normal night of sleep. At 5 am, performance in most psychometric tests showed significant impairment. As expected, largest effect sizes were found on performance in the Psychomotor Vigilance Test (PVT). Large effects sizes were also found in the Divided Attention Test (DAT), the Attention Network Test (ANT), and the test for Useful Field of View (UFOV) at 5 and 11 am during sleep deprivation. Effects of sleep deprivation on SDLP correlated significantly with performance changes in the PVT and the DAT, but not with performance changes in the UFOV. From the psychometric tests used in this study, the PVT and DAT seem most promising for initial evaluation of drug impairment based on sensitivity and correlations with driving impairment. Further studies are needed to assess the sensitivity and validity of these psychometric tests after benchmark sedative drug use.
Palucci Vieira, Luiz H; de Andrade, Vitor L; Aquino, Rodrigo L; Moraes, Renato; Barbieri, Fabio A; Cunha, Sérgio A; Bedo, Bruno L; Santiago, Paulo R
2017-12-01
The main aim of this study was to verify the relationship between the classification of coaches and actual performance in field tests that measure the kicking performance in young soccer players, using the K-means clustering technique. Twenty-three U-14 players performed 8 tests to measure their kicking performance. Four experienced coaches provided a rating for each player as follows: 1: poor; 2: below average; 3: average; 4: very good; 5: excellent as related to three parameters (i.e. accuracy, power and ability to put spin on the ball). The scores interval established from k-means cluster metric was useful to originating five groups of performance level, since ANOVA revealed significant differences between clusters generated (P<0.01). Accuracy seems to be moderately predicted by the penalty kick, free kick, kicking the ball rolling and Wall Volley Test (0.44≤r≤0.56), while the ability to put spin on the ball can be measured by the free kick and the corner kick tests (0.52≤r≤0.61). Body measurements, age and PHV did not systematically influence the performance. The Wall Volley Test seems to be a good predictor of other tests. Five tests showed reasonable construct validity and can be used to predict the accuracy (penalty kick, free kick, kicking a rolling ball and Wall Volley Test) and ability to put spin on the ball (free kick and corner kick tests) when kicking in soccer. In contrast, the goal kick, kicking the ball when airborne and the vertical kick tests exhibited low power of discrimination and using them should be viewed with caution.
Associations of physical fitness and academic performance among schoolchildren.
Van Dusen, Duncan P; Kelder, Steven H; Kohl, Harold W; Ranjit, Nalini; Perry, Cheryl L
2011-12-01
Public schools provide opportunities for physical activity and fitness surveillance, but are evaluated and funded based on students' academic performance, not their physical fitness. Empirical research evaluating the connections between fitness and academic performance is needed to justify curriculum allocations to physical activity programs. Analyses were based on a convenience sample of 254,743 individually matched standardized academic (TAKS™) and fitness (FITNESSGRAM(®) ) test records of students, grades 3-11, collected by 13 Texas school districts. We categorized fitness results in quintiles by age and gender and used mixed effects regression models to compare the academic performance of the top and bottom fitness groups for each test. All fitness variables except body mass index (BMI) showed significant, positive associations with academic performance after adjustment for socio-demographic covariates, with standardized mean difference effect sizes ranging from .07 to .34. Cardiovascular fitness showed the largest interquintile difference in TAKS score (32-75 points), followed by curl-ups. Additional adjustment for BMI and curl-ups showed dose-response associations between cardiovascular fitness and academic scores (p < .001 for both genders and outcomes). Analysis of BMI demonstrated limited, nonlinear association with academic performance after socio-demographic and fitness adjustments. Fitness was strongly and significantly related to academic performance. Cardiovascular fitness showed a dose-response association with academic performance independent of other socio-demographic and fitness variables. The association appears to peak in late middle to early high school. We recommend that policymakers consider physical education (PE) mandates in middle high school, school administrators consider increasing PE time, and PE practitioners emphasize cardiovascular fitness. © 2011, American School Health Association.
Preparation and Electrochemical Properties of Graphene/Epoxy Resin Composite Coating
NASA Astrophysics Data System (ADS)
Liao, Zijun; Zhang, Tianchi; Qiao, Sen; Zhang, Luyihang
2017-11-01
The multilayer graphene powder as filler, epoxy modified silicone resin as film-forming agent, anticorrosion composite coating has been created using sand dispersion method, the electrochemical performance was compared with different content of graphene composite coating and pure epoxy resin coating. The open circuit potential (OCP), potentiodynamic polarization curves (Tafel Plot) and electrochemical impedance spectroscopy (EIS) were tested. The test results showed that the anti-corrosion performance of multilayer graphene added has improved greatly, and the content of the 5% best corrosion performance of graphene composite coating.
PTS performance by flight- and control-group macaques
NASA Technical Reports Server (NTRS)
Washburn, D. A.; Rumbaugh, D. M.; Richardson, W. K.; Gulledge, J. P.; Shlyk, G. G.; Vasilieva, O. N.
2000-01-01
A total of 25 young monkeys (Macaca mulatta) were trained with the Psychomotor Test System, a package of software tasks and computer hardware developed for spaceflight research with nonhuman primates. Two flight monkeys and two control monkeys were selected from this pool and performed a psychomotor task before and after the Bion 11 flight or a ground-control period. Monkeys from both groups showed significant disruption in performance after the 14-day flight or simulation (plus one anesthetized day of biopsies and other tests), and this disruption appeared to be magnified for the flight animal.
Bilateral and unilateral cochlear implant users compared on speech perception in noise.
Dunn, Camille C; Noble, William; Tyler, Richard S; Kordus, Monika; Gantz, Bruce J; Ji, Haihong
2010-04-01
Compare speech performance in noise with matched bilateral cochlear implant (CICI) and unilateral cochlear implant (CI only) users. Thirty CICI and 30 CI-only subjects were tested on a battery of speech perception tests in noise that use an eight-loudspeaker array. On average, CICI subject's performance with speech in noise was significantly better than the CI-only subjects. The CICI group showed significantly better performance on speech perception in noise compared with the CI-only subjects, supporting the hypothesis that CICI is more beneficial than CI only.
Spatial disorientation in right-hemisphere infarction: a study of the speed of recovery.
Meerwaldt, J D
1983-01-01
Sixteen patients with an infarct in the posterior region of the right hemisphere were tested at fixed intervals after a stroke (2 weeks, 6 weeks, 3 months, 6 months, 1 year) with the rod orientation test and the line orientation test. All patients initially showed spatial disorientation on the rod orientation test, while only three had a defective performance on the line orientation test. The recovery on the rod orientation test was parallel with the neurological improvement. Recovery mainly took place in the first six months after the stroke. Most patients then performed at a normal level. A relation between the size of the lesion (assessed from CT scans) and the speed of recovery was found. PMID:6101178
Drake, David; Kennedy, Rodney; Wallace, Eric
2018-02-06
Isometric multi-joint tests are considered reliable and have strong relationships with 1RM performance. However, limited evidence is available for the isometric squat in terms of effects of familiarization and reliability. This study aimed to assess, the effect of familiarization, stability reliability, determine the smallest detectible difference, and the correlation of the isometric squat test with 1RM squat performance. Thirty-six strength-trained participants volunteered to take part in this study. Following three familiarization sessions, test-retest reliability was evaluated with a 48-hour window between each time point. Isometric squat peak, net and relative force were assessed. Results showed three familiarizations were required, isometric squat had a high level of stability reliability and smallest detectible difference of 11% for peak and relative force. Isometric strength at a knee angle of ninety degrees had a strong significant relationship with 1RM squat performance. In conclusion, the isometric squat is a valid test to assess multi-joint strength and can discriminate between strong and weak 1RM squat performance. Changes greater than 11% in peak and relative isometric squat performance should be considered as meaningful in participants who are familiar with the test.
Test anxiety and academic performance in chiropractic students.
Zhang, Niu; Henderson, Charles N R
2014-01-01
Objective : We assessed the level of students' test anxiety, and the relationship between test anxiety and academic performance. Methods : We recruited 166 third-quarter students. The Test Anxiety Inventory (TAI) was administered to all participants. Total scores from written examinations and objective structured clinical examinations (OSCEs) were used as response variables. Results : Multiple regression analysis shows that there was a modest, but statistically significant negative correlation between TAI scores and written exam scores, but not OSCE scores. Worry and emotionality were the best predictive models for written exam scores. Mean total anxiety and emotionality scores for females were significantly higher than those for males, but not worry scores. Conclusion : Moderate-to-high test anxiety was observed in 85% of the chiropractic students examined. However, total test anxiety, as measured by the TAI score, was a very weak predictive model for written exam performance. Multiple regression analysis demonstrated that replacing total anxiety (TAI) with worry and emotionality (TAI subscales) produces a much more effective predictive model of written exam performance. Sex, age, highest current academic degree, and ethnicity contributed little additional predictive power in either regression model. Moreover, TAI scores were not found to be statistically significant predictors of physical exam skill performance, as measured by OSCEs.
A Study of relationship between frailty and physical performance in elderly women
Jeoung, Bog Ja; Lee, Yang Chool
2015-01-01
Frailty is a disorder of multiple inter-related physiological systems. It is unclear whether the level of physical performance factors can serve as markers of frailty and a sign. The purpose of this study was to examine the relationship between frailty and physical performance in elderly women. One hundred fourteen elderly women participated in this study, their aged was from 65 to 80. We were measured 6-min walk test, grip-strength, 30-sec arm curl test, 30-sec chair stand test, 8 foot Up- and Go, Back scratch, chair sit and reach, unipedal stance, BMI, and the frailty with questionnaire. The collected data were analyzed by descriptive statistics, frequencies, correlation analysis, ANOVA, and simple liner regression using the IBM 21. SPSS program. In results, statistic tests showed that there were significant differences between frailty and 6-min walk test, 30-sec arm curl test, 30-sec chair stand test, grip-strength, Back scratch, and BMI. However, we did not find significant differences between frailty and 8 foot Up- and Go, unipedal stance. When the subjects were divided into five groups according to physical performance level, subjects with high 6-min walk, 30-sec arm curl test, chair sit and reach test, and high grip strength had low score frailty. Physical performance factors were strongly associated with decreased frailty, suggesting that physical performance improvements play an important role in preventing or reducing the frailty. PMID:26331137
Munguía-Izquierdo, Diego; Legaz-Arrese, Alejandro
2012-11-01
To evaluate the reliability, standard error of the mean (SEM), clinical significant change, and known group validity of 2 assessments of endurance strength to low loads in patients with fibromyalgia syndrome (FS). Cross-sectional reliability and comparative study. University Pablo de Olavide, Seville, Spain. Middle-aged women with FS (n=95) and healthy women (n=64) matched for age, weight, and body mass index (BMI) were recruited for the study. Not applicable. The endurance strength to low loads tests of the upper and lower extremities and anthropometric measures (BMI) were used for the evaluations. The differences between the readings (tests 1 and 2) and the SDs of the differences, intraclass correlation coefficient (ICC) model (2,1), 95% confidence interval for the ICC, coefficient of repeatability, intrapatient SD, SEM, Wilcoxon signed-rank test, and Bland-Altman plots were used to examine reliability. A Mann-Whitney U test was used to analyze the differences in test values between the patient group and the control group. We hypothesized that patients with FS would have an endurance strength to low loads performance in lower and upper extremities at least twice as low as that of the healthy controls. Satisfactory test-retest reliability and SEMs were found for the lower extremity, dominant arm, and nondominant arm tests (ICC=.973-.979; P<.001; SEMs=1.44-1.66 repetitions). The differences in the mean between the test and retest were lower than the SEM for all performed tests, varying from -.10 to .29 repetitions. No significant differences were found between the test and retest (P>.05 for all). The Bland-Altman plots showed 95% limits of agreement for the lower extremity (4.7 to -4.5), dominant arm (3.8 to -4.4), and nondominant arm (3.9 to -4.1) tests. The endurance strength to low loads test scores for the patients with FS were 4-fold lower than for the controls in all performed tests (P<.001 for all). The endurance strength to low loads tests showed good reliability and known group validity and can be recommended for evaluating endurance strength to low loads in patients with FS. For individual evaluation, however, an improved score of at least 4 and 5 repetitions for the upper and lower extremities, respectively, was required for the differences to be considered as substantial clinical change. Patients with FS showed impaired endurance strength to low loads performance when compared with the general population. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Clemensson, Erik Karl Håkan; Clemensson, Laura Emily; Fabry, Benedikt; Riess, Olaf; Nguyen, Huu Phuc
2017-01-01
Huntington disease is an inherited neurodegenerative disorder characterized by motor, cognitive, psychiatric and metabolic symptoms. We recently published a study describing that the BACHD rat model of HD shows an obesity phenotype, which might affect their motivation to perform food-based behavioral tests. Further, we argued that using a food restriction protocol based on matching BACHD and wild type rats' food consumption rates might resolve these motivational differences. In the current study, we followed up on these ideas in a longitudinal study of the rats' performance in a progressive ratio test. We also investigated the phenotype of reduced food consumption rate, which is typically seen in food-restricted BACHD rats, in greater detail. In line with our previous study, the BACHD rats were less motivated to perform the progressive ratio test compared to their wild type littermates, although the phenotype was no longer present when the rats' food consumption rates had been matched. However, video analysis of food consumption tests suggested that the reduced consumption rate found in the BACHD rats was not entirely based on differences in hunger, but likely involved motoric impairments. Thus, restriction protocols based on food consumption rates are not appropriate when working with BACHD rats. As an alternative, we suggest that studies where BACHD rats are used should investigate how the readouts of interest are affected by motivational differences, and use appropriate control tests to avoid misleading results. In addition, we show that BACHD rats display distinct behavioral changes in their progressive ratio performance, which might be indicative of striatal dysfunction.
Design, construction, operation, and evaluation of a prototype culm combustion boiler/heater unit
DOE Office of Scientific and Technical Information (OSTI.GOV)
D'Aciermo, J.; Richards, H.; Spindler, F.
1983-10-01
A process for utilizing anthracite culm in a fluidized bed combustion system was demonstrated by the design and construction of a prototype steam plant at Shamokin, PA, and operation of the plant for parametric tests and a nine month extended durability test. The parametric tests evaluated turndown capability of the plant and established turndown techniques to be used to achieve best performance. Throughout the test program the fluidized bed boiler durability was excellent, showing very high resistence to corrosion and erosion. A series of 39 parametric tests was performed in order to demonstrate turndown capabilities of the atmospheric fluidized bedmore » boiler burning anthracite culm. Four tests were performed with bituminous coal waste (called gob) which contains 4.8 to 5.5% sulfur. Heating value of both fuels is approximately 3000 Btu/lb and ash content is approximately 70%. Combustion efficiency, boiler efficiency, and emissions of NO/sub x/ and SO/sub 2/ were also determined for the tests.« less
Lima, Cristina Jardelino de; Falci, Saulo Gabriel Moreira; Rodrigues, Danillo Costa; Marchiori, Érica Cristina; Moreira, Roger Willian Fernandes
2015-12-01
The aim of the present study was to use mechanical and photoelastic tests to compare the performance of cannulated screws with solid-core screws in sagittal split osteotomy fixation. Ten polyurethane mandibles, with a prefabricated sagittal split ramus osteotomy, were fixed with an L inverted technique and allocated to each group as follows: cannulated screw group (CSG), fixed with three 2.3-cannulated screws; and solid-core screw group (SCSG), fixed with three 2.3-solid-core screws. Vertical linear loading tests were performed. The differences between mean values were analyzed through T test for independent samples. The photoelastic test was carried out using a polariscope. The results revealed differences between the two groups only at 1 mm of displacement, in which the cannulated-screw revealed more resistance. Photoelastic test showed higher stress concentration close to mandibular branch in the solid-core group. Cannulated screws performed better than solid-core ones in a mechanical test at 1-mm displacement and photoelastic tests.
Designing a warm-up protocol for elite bob-skeleton athletes.
Cook, Christian; Holdcroft, Danny; Drawer, Scott; Kilduff, Liam P
2013-03-01
To investigate how different warm-ups influenced subsequent sled-pull sprint performance in Olympic-level bob-skeleton athletes as part of their preparation for the 2010 Winter Olympics. Three female and 3 male athletes performed 5 different randomized warm-ups of differing intensities, durations, and timing relative to subsequent testing, each 2 days apart, all repeated twice. After warm-ups, testing on a sled-pull sprint over 20 m, 3 repeats 3 min apart, took place. Performance testing showed improvement (P < .001, ES > 1.2) with both increasing intensity of warm-up and closeness of completion to testing, with 20-m sled sprinting being 0.1-0.25 s faster in higher-intensity protocols performed near testing In addition, supplementing the warm-ups by wearing of a light survival coat resulted in further performance improvement (P = .000, ES 1.8). Changing timing and intensity of warm-up and using an ancillary passive heat-retention device improved sprint performance in Olympic-level bob-skeleton athletes. Subsequent adoption of these on the competitive circuit was associated with a seasonal improvement in push times and was ultimately implemented in the 2010 Winter Olympics.
ERIC Educational Resources Information Center
Harris, Gina; Johhson, Suzanne Bennett
1980-01-01
Individualized covert modeling and self-control desensitization substantially reduced self-reported test anxiety. However, the individualized covert modeling group was the only treatment group that showed significant improvement in academic performance. (Author)
The cooking task: making a meal of executive functions
Doherty, T. A.; Barker, L. A.; Denniss, R.; Jalil, A.; Beer, M. D.
2015-01-01
Current standardized neuropsychological tests may fail to accurately capture real-world executive deficits. We developed a computer-based Cooking Task (CT) assessment of executive functions and trialed the measure with a normative group before use with a head-injured population. Forty-six participants completed the computerized CT and subtests from standardized neuropsychological tasks, including the Tower and Sorting Tests of executive function from the Delis-Kaplan Executive Function System (D-KEFS) and the Cambridge prospective memory test (CAMPROMPT), in order to examine whether standardized executive function tasks, predicted performance on measurement indices from the CT. Findings showed that verbal comprehension, rule detection and prospective memory contributed to measures of prospective planning accuracy and strategy implementation of the CT. Results also showed that functions necessary for cooking efficacy differ as an effect of task demands (difficulty levels). Performance on rule detection, strategy implementation and flexible thinking executive function measures contributed to accuracy on the CT. These findings raise questions about the functions captured by present standardized tasks particularly at varying levels of difficulty and during dual-task performance. Our preliminary findings also indicate that CT measures can effectively distinguish between executive function and Full Scale IQ abilities. Results of the present study indicate that the CT shows promise as an ecologically valid measure of executive function for future use with a head-injured population and indexes selective executive function’s captured by standardized tests. PMID:25717294
Phonological awareness and the working memory of children with and without literacy difficulties.
Cardoso, Andreia Martins de Souza; Silva, Mônica Marins da; Pereira, Mônica Medeiros de Britto
2013-01-01
To investigate phonological awareness and working memory skills as well as their influence on the literacy process in a group of intellectually normal children. Forty intellectually normal children (7.6-8.0 years) from the second and third grades of elementary school participated. Children were organized in two groups (20 children each): one with and another without literacy difficulties. These participants underwent RAVEN's intelligence quotient test, audiometric assessment, CONFIAS test of phonological awareness, written spelling task, and working memory test. Children in the alphabetic phase presented a good development of phonological awareness, and 85% of them showed a high-performance working memory. Children in the syllabic-alphabetic phase had changes in phonological awareness, and 91.6% of them showed an average working memory performance. The subjects at pre-syllabic and syllabic phases demonstrated more difficulties in phonological awareness than those at syllabic-alphabetic and had a poor working memory performance. Between-group differences were observed for CONFIAS and working memory tests (p<0.0001). There was also a significant correlation (r=0.78, p=0.01) between the skills of phonological awareness and working memory for the total sample of individuals. Based on these results, it was found that as phonological awareness and working memory levels increased, the literacy phase also advanced, therefore showing that these are directly proportional measures.
The cooking task: making a meal of executive functions.
Doherty, T A; Barker, L A; Denniss, R; Jalil, A; Beer, M D
2015-01-01
Current standardized neuropsychological tests may fail to accurately capture real-world executive deficits. We developed a computer-based Cooking Task (CT) assessment of executive functions and trialed the measure with a normative group before use with a head-injured population. Forty-six participants completed the computerized CT and subtests from standardized neuropsychological tasks, including the Tower and Sorting Tests of executive function from the Delis-Kaplan Executive Function System (D-KEFS) and the Cambridge prospective memory test (CAMPROMPT), in order to examine whether standardized executive function tasks, predicted performance on measurement indices from the CT. Findings showed that verbal comprehension, rule detection and prospective memory contributed to measures of prospective planning accuracy and strategy implementation of the CT. Results also showed that functions necessary for cooking efficacy differ as an effect of task demands (difficulty levels). Performance on rule detection, strategy implementation and flexible thinking executive function measures contributed to accuracy on the CT. These findings raise questions about the functions captured by present standardized tasks particularly at varying levels of difficulty and during dual-task performance. Our preliminary findings also indicate that CT measures can effectively distinguish between executive function and Full Scale IQ abilities. Results of the present study indicate that the CT shows promise as an ecologically valid measure of executive function for future use with a head-injured population and indexes selective executive function's captured by standardized tests.
Guayerbas, Noelia; Catalán, Marina; Víctor, Víctor M; Miquel, Jaime; De la Fuente, Mónica
2002-08-21
According to our previous work, mice of the same strain and age show striking inter-individual differences in behaviour when exposed to a T-maze test. Further, the animals exploring the maze slowly (slow mice) or staying at the starting point (freezing behaviour), which show high levels of emotionality/anxiety in other standard behavioural tests, have a less competent immune system (earlier immunosenescence) than those which explore it quickly (fast mice). The present longitudinal study on OF-1 Swiss female mice confirms and extends the above findings. Thus, the animals showing a lower performance in the T-test (slow mice) which is accompanied by a poor neuromuscular coordination in a tightrope test, have a shorter life span than the good performers (fast mice). Moreover, the slow mice have a less competent immune system as regards the following functions of peritoneal macrophages: adherence to substrate, chemotaxis, ingestion of particles and superoxide anion production. This suggests that, at the same chronological age and as regards their immune competence, the slow mice are biologically older than the fast mice. This agrees with current ideas on the close functional relationship between the nervous and the immune system in the physiological adaptation to stress, and supports the concept that an optimum level of performance of these two systems is needed to attain a long life span. Copyright 2002 Elsevier Science B.V.
Lorens, Artur; Zgoda, Małgorzata; Obrycka, Anita; Skarżynski, Henryk
2010-12-01
Presently, there are only few studies examining the benefits of fine structure information in coding strategies. Against this background, this study aims to assess the objective and subjective performance of children experienced with the C40+ cochlear implant using the CIS+ coding strategy who were upgraded to the OPUS 2 processor using FSP and HDCIS. In this prospective study, 60 children with more than 3.5 years of experience with the C40+ cochlear implant were upgraded to the OPUS 2 processor and fit and tested with HDCIS (Interval I). After 3 months of experience with HDCIS, they were fit with the FSP coding strategy (Interval II) and tested with all strategies (FSP, HDCIS, CIS+). After an additional 3-4 months, they were assessed on all three strategies and asked to choose their take-home strategy (Interval III). The children were tested using the Adaptive Auditory Speech Test which measures speech reception threshold (SRT) in quiet and noise at each test interval. The children were also asked to rate on a Visual Analogue Scale their satisfaction and coding strategy preference when listening to speech and a pop song. However, since not all tests could be performed at one single visit, some children were not able complete all tests at all intervals. At the study endpoint, speech in quiet showed a significant difference in SRT of 1.0 dB between FSP and HDCIS, with FSP performing better. FSP proved a better strategy compared with CIS+, showing lower SRT results of 5.2 dB. Speech in noise tests showed FSP to be significantly better than CIS+ by 0.7 dB, and HDCIS to be significantly better than CIS+ by 0.8 dB. Both satisfaction and coding strategy preference ratings also revealed that FSP and HDCIS strategies were better than CIS+ strategy when listening to speech and music. FSP was better than HDCIS when listening to speech. This study demonstrates that long-term pediatric users of the COMBI 40+ are able to upgrade to a newer processor and coding strategy without compromising their listening performance and even improving their performance with FSP after a short time of experience. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Loturco, Irineu; Winckler, Ciro; Kobal, Ronaldo; Cal Abad, Cesar C.; Kitamura, Katia; Veríssimo, Amaury W.; Pereira, Lucas A.; Nakamura, Fábio Y.
2015-01-01
The aims of this study were to estimate the magnitude of variability and progression in actual competitive and field vertical jump test performances in elite Paralympic sprinters with visual impairment in the year leading up to the 2015 Parapan American Games, and to investigate the relationships between loaded and unloaded vertical jumping test results and actual competitive sprinting performance. Fifteen Brazilian Paralympic sprinters with visual impairment attended seven official competitions (four national, two international and the Parapan American Games 2015) between April 2014 and August 2015, in the 100- and 200-m dash. In addition, they were tested in five different periods using loaded (mean propulsive power [MPP] in jump squat [JS] exercise) and unloaded (squat jump [SJ] height) vertical jumps within the 3 weeks immediately prior to the main competitions. The smallest important effect on performances was calculated as half of the within-athlete race-to-race (or test-to-test) variability and a multiple regression analysis was performed to predict the 100- and 200-m dash performances using the vertical jump test results. Competitive performance was enhanced during the Parapan American Games in comparison to the previous competition averages, overcoming the smallest worthwhile enhancement in both the 100- (0.9%) and 200-m dash (1.43%). In addition, The SJ and JS explained 66% of the performance variance in the competitive results. This study showed that vertical jump tests, in loaded and unloaded conditions, could be good predictors of the athletes' sprinting performance, and that during the Parapan American Games the Brazilian team reached its peak competitive performance. PMID:26594181
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jensen, Colby B.; Folsom, Charles P.; Davis, Cliff B.
Experimental testing in the Multi-Static Environment Rodlet Transient Test Apparatus (SERTTA) will lead the rebirth of transient fuel testing in the United States as part of the Accident Tolerant Fuels (ATF) progam. The Multi-SERTTA is comprised of four isolated pressurized environments capable of a wide variety of working fluids and thermal conditions. Ultimately, the TREAT reactor as well as the Multi-SERTTA test vehicle serve the purpose of providing desired thermal-hydraulic boundary conditions to the test specimen. The initial ATF testing in TREAT will focus on reactivity insertion accident (RIA) events using both gas and water environments including typical PWR operatingmore » pressures and temperatures. For the water test environment, a test configuration is envisioned using the expansion tank as part of the gas-filled expansion volume seen by the test to provide additional pressure relief. The heat transfer conditions during the high energy power pulses of RIA events remains a subject of large uncertainty and great importance for fuel performance predictions. To support transient experiments, the Multi-SERTTA vehicle has been modeled using RELAP5 with a baseline test specimen composed of UO2 fuel in zircaloy cladding. The modeling results show the influence of the designs of the specimen, vehicle, and transient power pulses. The primary purpose of this work is to provide input and boundary conditions to fuel performance code BISON. Therefore, studies of parameters having influence on specimen performance during RIA transients are presented including cladding oxidation, power pulse magnitude and width, cladding-to-coolant heat fluxes, fuel-to-cladding gap, transient boiling effects (modified CHF values), etc. The results show the great flexibility and capacity of the TREAT Multi-SERTTA test vehicle to provide testing under a wide range of prototypic thermal-hydraulic conditions as never done before.« less
Mendicino, Diego; Stafuza, Mariana; Colussi, Carlina; del Barco, Mónica; Streiger, Mirtha; Moretti, Edgardo
2014-01-01
Many patients with Chagas disease live in remote communities that lack both equipment and trained personnel to perform a diagnosis by conventional serology (CS). Thus, reliable tests suitable for use under difficult conditions are required. In this study, we evaluated the ability of personnel with and without laboratory skills to perform immunochromatographic (IC) tests to detect Chagas disease at a primary health care centre (PHCC). We examined whole blood samples from 241 patients and serum samples from 238 patients. Then, we calculated the percentage of overall agreement (POA) between the two groups of operators for the sensitivity (S), specificity (Sp) and positive (PPV) and negative (NPV) predictive values of IC tests compared to CS tests. We also evaluated the level of agreement between ELISAs and indirect haemagglutination (IHA) tests. The readings of the IC test results showed 100% agreement (POA = 1). The IC test on whole blood showed the following values: S = 87.3%; Sp = 98.8%; PPV = 96.9% and NPV = 95.9%. Additionally, the IC test on serum displayed the following results: S = 95.7%; Sp = 100%; PPV = 100% and NPV = 98.2%. Using whole blood, the agreement with ELISA was 96.3% and the agreement with IHA was 94.1%. Using serum, the agreement with ELISA was 97.8% and the agreement with IHA was 96.6%. The IC test performance with serum samples was excellent and demonstrated its usefulness in a PHCC with minimal equipment. If the IC test S value and NPV with whole blood are improved, then this test could also be used in areas lacking laboratories or specialised personnel. PMID:25466624
What Do Test Score Really Mean? A Latent Class Analysis of Danish Test Score Performance
ERIC Educational Resources Information Center
McIntosh, James; Munk, Martin D.
2014-01-01
Latent class Poisson count models are used to analyse a sample of Danish test score results from a cohort of individuals born in 1954-1955, tested in 1968, and followed until 2011. The procedure takes account of unobservable effects as well as excessive zeros in the data. We show that the test scores measure manifest or measured ability as it has…
Progress of Ongoing NASA Lithium-Ion Cell Verification Testing for Aerospace Applications
NASA Technical Reports Server (NTRS)
McKissock, Barbara I.; Manzo, Michelle A.; Miller, Thomas B.; Reid, Concha M.; Bennett, William R.; Gemeiner, Russel
2008-01-01
A Lithium-ion Verification and Validation Program with the purpose to assess the capabilities of current aerospace lithium-ion (Li-ion) battery cells to perform in a low-earth-orbit (LEO) regime was initiated in 2002. This program involves extensive characterization and LEO life testing at ten different combinations of depth-of-discharge, temperature, and end-of-charge voltage. The test conditions selected for the life tests are defined as part of a statistically designed test matrix developed to determine the effects of operating conditions on performance and life of Li-ion cells. Results will be used to model and predict cell performance and degradation as a function of test operating conditions. Testing is being performed at the Naval Surface Warfare Center/Crane Division in Crane, Indiana. Testing was initiated in September 2004 with 40 Ah cells from Saft and 30 Ah cells from Lithion. The test program has been expanded with the addition of modules composed of 18650 cells from ABSL Power Solutions in April 2006 and the addition of 50 Ah cells from Mine Safety Appliances Co. (MSA) in June 2006. Preliminary results showing the average voltage and average available discharge capacity for the Saft and Lithion packs at the test conditions versus cycles are presented.
Shirasawa, Shinichi; Koga, Hideyuki; Horie, Masafumi; Nakamura, Tomomasa; Watanabe, Toshifumi; Sekiya, Ichiro; Muneta, Takeshi
2016-12-01
To investigate fear in patients with anterior cruciate ligament (ACL) injury before and after reconstruction, a forced knee extension (FKE) test was performed. The correlation of the test results was evaluated with the subjective function, sports performance and objective parameters. The study included 102 patients with unilateral ACL reconstruction using a semitendinosus tendon with full clinical evaluation. This study was retrospective and determined the longitudinal results of the FKE test and investigated the effects on the subjective and objective outcomes at 2years. Preoperatively, 47% of patients showed positive FKE tests. The number of positive FKE tests was 31% at six months and 15% at 24months after ACL reconstruction. At two years, there were statistically significant differences between the FKE test positives and negatives regarding both subjective knee recovery (P=0.0095) and sports performance (P=0.0006). A new manual test, called the forced knee extension test, for fear in patients with ACL injury before and after reconstruction was introduced. The apprehension remained positive in 15% of the patients two years after ACL reconstruction, which affected subjective recovery of knee function and sports performance. Copyright © 2016 Elsevier B.V. All rights reserved.
Haverkate, Liz; Smit, Gerwin; Plettenburg, Dick H
2016-02-01
The functional performance of currently available body-powered prostheses is unknown. The goal of this study was to objectively assess and compare the functional performance of three commonly used body-powered upper limb terminal devices. Experimental trial. A total of 21 able-bodied subjects (n = 21, age = 22 ± 2) tested three different terminal devices: TRS voluntary closing Hook Grip 2S, Otto Bock voluntary opening hand and Hosmer Model 5XA hook, using a prosthesis simulator. All subjects used each terminal device nine times in two functional tests: the Nine-Hole Peg Test and the Box and Blocks Test. Significant differences were found between the different terminal devices and their scores on the Nine-Hole Peg Test and the Box and Blocks Test. The Hosmer hook scored best in both tests. The TRS Hook Grip 2S scored second best. The Otto Bock hand showed the lowest scores. This study is a first step in the comparison of functional performances of body-powered prostheses. The data can be used as a reference value, to assess the performance of a terminal device or an amputee. The measured scores enable the comparison of the performance of a prosthesis user and his or her terminal device relative to standard scores. © The International Society for Prosthetics and Orthotics 2014.
NASA Technical Reports Server (NTRS)
Gaddis, Stephen W.; Hudson, Susan T.; Johnson, P. D.
1992-01-01
NASA's Marshall Space Flight Center has established a cold airflow turbine test program to experimentally determine the performance of liquid rocket engine turbopump drive turbines. Testing of the SSME alternate turbopump development (ATD) fuel turbine was conducted for back-to-back comparisons with the baseline SSME fuel turbine results obtained in the first quarter of 1991. Turbine performance, Reynolds number effects, and turbine diagnostics, such as stage reactions and exit swirl angles, were investigated at the turbine design point and at off-design conditions. The test data showed that the ATD fuel turbine test article was approximately 1.4 percent higher in efficiency and flowed 5.3 percent more than the baseline fuel turbine test article. This paper describes the method and results used to validate the ATD fuel turbine aerodynamic design. The results are being used to determine the ATD high pressure fuel turbopump (HPFTP) turbine performance over its operating range, anchor the SSME ATD steady-state performance model, and validate various prediction and design analyses.
Özyurt, Jale; Thiel, Christiane M; Lorenzen, Anna; Gebhardt, Ursel; Calaminus, Gabriele; Warmuth-Metz, Monika; Müller, Hermann L
2014-04-01
To test memory performance and executive functions in patients with childhood craniopharyngioma and hypothalamic involvement. Using standardized neuropsychological tests, we compared cognitive performance in a group of 15 patients with childhood craniopharyngioma and known hypothalamic involvement and a group of 24 age- and intelligence-matched control subjects. In addition, we compared individual patients' results with normative data to detect abnormal performance in the clinically relevant range. Within the patient group, we further tested whether the grade of hypothalamic involvement had an impact on cognitive performance and quality of life. Relative to healthy controls, the patients demonstrated significantly lower performance scores in tests of memory and executive functioning. On the individual performance level, delayed recall performance was severely impaired in one-third of the patients. Compared with patients with low-grade hypothalamic involvement, those with high-grade hypothalamic involvement showed worse performance in executive functions and reduced functional capabilities for daily life actions, indicating lower quality of life. Our findings demonstrate that hypothalamic involvement is related to impairments in memory and executive functioning in patients with childhood craniopharyngioma and indicate that a high grade of hypothalamic involvement is related to worse outcomes. Copyright © 2014 Mosby, Inc. All rights reserved.
Geopathic stress zones: short-term effects on work performance and well-being?
Augner, Christoph; Hacker, Gerhard W; Jekel, Ilse
2010-06-01
The aim of the study was to evaluate whether two different locations in the same room as tested by dowsers ("geopathic stress zone" [GSZ] versus "more neutral zone" [NZ]) would show significant short-term effects on work performance and well-being. It was also tested whether a device reported to "neutralize" GSZ would influence results obtained with the specific setup used in this study. This was a blinded, randomized, short-term laboratory experiment using a within-subject design. The study was conducted in the laboratory of the Research Institute for Frontier Questions of Medicine and Biotechnology at Salzburg Federal Hospital. The subjects were 26 persons, aged 20-57. Participants had to accomplish reaction tasks during three different conditions: GSZ, NZ, and GSZ with a device reported to "neutralize" GSZ. These conditions were counterbalanced into six different sequences and randomized to the subjects. At the end of each condition, a standardized well-being questionnaire had to be completed. Dependent variables were reactive stress tolerance (reaction time, timely right answers, right answers, false answers, left out) and well-being (described by six adjectives). No location-dependent effects on performance during reactive stress tolerance test were seen. For well-being, analysis of variance revealed a trend (p = 0.07) and showed significantly poorer well-being during the GSZ condition compared to NZ (p = 0.01). This study shows that well-being can be location dependent and that this might be caused by a so-called GSZ. However, in our short-term experiment, factors of work performance tested remained unaffected.
1978-09-01
This photograph shows stacking of the left side of the solid rocket booster (SRB) segments in the Dynamic Test Stand at the east test area of the Marshall Space Flight Center (MSFC). Staging shown here are the aft skirt, aft segment, and aft center segment. The SRB was attached to the external tank (ET) and then the orbiter later for the Mated Vertical Ground Vibration Test (MVGVT), that resumed in October 1978. The stacking of a complete Shuttle in the Dynamic Test Stand allowed test engineers to perform ground vibration testing on the Shuttle in its liftoff configuration. The purpose of the MVGVT is to verify that the Space Shuttle would perform as predicted during launch. The platforms inside the Dynamic Test Stand were modified to accommodate two SRB's to which the ET was attached.
1978-09-01
This photograph shows the left side of the solid rocket booster (SRB) segment as it awaits being mated to the nose cone and forward skirt in the Dynamic Test Stand at the east test area of the Marshall Space Flight Center (MSFC). The SRB would be attached to the external tank (ET) and then the orbiter later for the Mated Vertical Ground Vibration Test (MVGVT), that resumed in October 1978. The stacking of a complete Shuttle in the Dynamic Test Stand allowed test engineers to perform ground vibration testing on the Shuttle in its liftoff configuration. The purpose of the MVGVT was to verify that the Space Shuttle would perform as predicted during launch. The platforms inside the Dynamic Test Stand were modified to accommodate two SRB's to which the ET was attached.
Integrating the internal and external training loads in soccer.
Akubat, Ibrahim; Barrett, Steve; Abt, Grant
2014-05-01
This study aimed to assess the relationships of fitness in soccer players with a novel integration of internal and external training load (TL). Ten amateur soccer players performed a lactate threshold (LT) test followed by a soccer simulation (Ball-Sport Endurance and Sprint Test [BEAST90mod]). The results from the LT test were used to determine velocity at lactate threshold (vLT), velocity at onset of blood lactate accumulation (vOBLA), maximal oxygen uptake (VO2max), and the heart rate-blood lactate profile for calculation of internal TL (individualized training impulse, or iTRIMP). The total distance (TD) and high intensity distance (HID) covered during the BEAST90mod were measured using GPS technology that allowed measurement of performance and external TL. The internal TL was divided by the external TL to form TD:iTRIMP and HID:iTRIMP ratios. Correlation analyses assessed the relationships between fitness measures and the ratios to performance in the BEAST90mod. vLT, vOBLA, and VO2max showed no significant relationship to TD or HID. HID:iTRIMP significantly correlated with vOBLA (r = .65, P = .04; large), and TD:iTRIMP showed a significant correlation with vLT (r = .69, P = .03; large). The results suggest that the integrated use of ratios may help in the assessment of fitness, as performance alone showed no significant relationships with fitness.
Wave Fluid Film Bearing Tests for an Aviation Gearbox
NASA Technical Reports Server (NTRS)
Dimofte, Florin; Proctor, Margaret P.; Fleming, David P.; Keith, Theo G., Jr.
2000-01-01
An oil-lubricated wave journal-thrust bearing assembly was successfully tested at conditions found in general aviation engine gearboxes. The bearing performed well at both steady state conditions and in start-stop tests. It ran stably under all loading conditions, including zero load, at all speeds up to 16 000 rpm. The bearing carried 25 percent more load than required for the gearbox application, supporting 8900 N (94 bars average pressure), and showed very good thermal stability. 450 start-stop cycles were also performed, including 350 cycles without oil supply during starting and stopping. Test results and numerical predictions were in good agreement.
Test results of a 40-kW Stirling engine and comparison with the NASA Lewis computer code predictions
NASA Technical Reports Server (NTRS)
Allen, David J.; Cairelli, James E.
1988-01-01
A Stirling engine was tested without auxiliaries at Nasa-Lewis. Three different regenerator configurations were tested with hydrogen. The test objectives were: (1) to obtain steady-state and dynamic engine data, including indicated power, for validation of an existing computer model for this engine; and (2) to evaluate structurally the use of silicon carbide regenerators. This paper presents comparisons of the measured brake performance, indicated mean effective pressure, and cyclic pressure variations from those predicted by the code. The silicon carbide foam generators appear to be structurally suitable, but the foam matrix showed severely reduced performance.
Tang, Zhiteng; Xu, Ye; Song, Najie; Zou, Dongqing; Liao, Yiqun; Li, Qingge; Pan, Chao
2018-03-01
The clinical performance of the newly developed MeltPro ® HPV Test, based on multicolor melting curve analysis, was evaluated and compared with the commercially available Cobas ® HPV Test for detection of HPV and genotyping of HPV-16 and HPV-18. A total of 1647 cervical samples were analyzed with both tests. The agreement values were 96.2% for HPV detection, 99.6% for HPV-16 identification, and 99.7% for HPV-18 identification. All genotyping results from MeltPro ® HPV Test showed that HPV-52, HPV-58, and HPV-16 were the most common types in this study. Intra-laboratory reproducibility studies showed 97.8% agreement while inter-laboratory reproducibility studies showed 96.9% agreement for the MeltPro ® HPV Test. The MeltPro ® HPV Test and Cobas ® HPV Test are highly correlative and are useful for monitoring HPV infection.
Effect of wrist cooling on aerobic and anaerobic performance in elite sportsmen.
Krishnan, Anup; Singh, Krishan; Sharma, Deep; Upadhyay, Vivekanand; Singh, Amit
2018-01-01
Body cooling has been used to increase sporting performance and enhance recovery. Several studies have reported improvement in exercise capacities using forearm and hand cooling or only hand cooling. Wrist cooling has emerged as a portable light weight solution for precooling prior to sporting activity. The Astrand test for aerobic performance and the Wingate test for anaerobic performance are reliable and accurate tests for performance assessment. This study conducted on elite Indian athletes analyses the effects of wrist precooling on aerobic and anaerobic performance as tested by the Astrand test and the Wingate test before and after wrist precooling. 67 elite sportsmen were administered Wingate and Astrand test under standardised conditions with and without wrist precooling using a wrist cooling device (dhamaSPORT). Paired t -test was applied to study effect on aerobic [VO 2 (ml/min/kg)] and anaerobic performance [peak power (W/kg) and average power (W/kg)] and Cohen's d was used to calculate effect size of wrist precooling. After wrist precooling, significant increase of 0.22 ( p = 0.014, 95% CI: 0.047, 0.398) in peak power (W/kg) and 0.22 ( p < 0.0001, 95% CI: 0.142, 0.291) was observed in average power (W/kg). Although, an increase of 1.38 ( p = 0.097, 95% CI: -0.225, 3.012) was observed in VO 2 (ml/min/kg), wrist precooling was not significantly effective in aerobic performance. Wrist cooling effect size was smaller in VO 2 (Cohen's d = 0.21), peak power (Cohen's d = 0.31) and it was larger in average power (Cohen's d = 0.71). Results show wrist precooling significantly improves anaerobic than aerobic performance of elite sportsmen.
[Psychological results of mental performance in sleep deprivation].
Dahms, P; Schaad, G; Gorges, W; von Restorff, W
1996-01-01
To quantify the effects of sleep periods that have different lengths of time during continuous operations (CONOPS) 2 independent groups of subjects performed several cognitive tasks for 3 days. The 72 h trial period contained three 60-min sleep periods for the 10 subjects of the experimental group and three sleep periods of 4 h each for the 14 subjects of the control group. With the exception of only one subtest the statistical analyses of the test results of the 2 groups show no significant differences in cognitive performance. It is suggested that high motivation is responsible for comparable performance of the subjects, which was essentially obtained by a monetary pay system for successful test performance.
Study of skin model and geometry effects on thermal performance of thermal protective fabrics
NASA Astrophysics Data System (ADS)
Zhu, Fanglong; Ma, Suqin; Zhang, Weiyuan
2008-05-01
Thermal protective clothing has steadily improved over the years as new materials and improved designs have reached the market. A significant method that has brought these improvements to the fire service is the NFPA 1971 standard on structural fire fighters’ protective clothing. However, this testing often neglects the effects of cylindrical geometry on heat transmission in flame resistant fabrics. This paper deals with methods to develop cylindrical geometry testing apparatus incorporating novel skin bioheat transfer model to test flame resistant fabrics used in firefighting. Results show that fabrics which shrink during the test can have reduced thermal protective performance compared with the qualities measured with a planar geometry tester. Results of temperature differences between skin simulant sensors of planar and cylindrical tester are also compared. This test method provides a new technique to accurately and precisely characterize the thermal performance of thermal protective fabrics.
Sekaquaptewa, Denise; Waldman, Andrew; Thompson, Mischa
2007-10-01
A preliminary study and main experiment tested the hypothesis that racial solo status (being the only member of one's race in a group) increases racial self-construal among African Americans. The preliminary study showed that African American men and women reported greater collectivist (i.e., group-based) over individualist self-construal under solo compared to nonsolo status, whereas Whites did not. The main experiment showed that the increased collectivism among African American solo women appears to be strongly reflected in racial identity becoming a salient aspect of self-construal. African American participants were also more likely than Whites to perceive that their anticipated performance would be generalized to their race, to feel like representatives of their race, and to show greater performance apprehension (indirectly evidenced by increased self-handicapping) when in racial solo status. The implications of solo status for African Americans in evaluative situations (such as academic testing sessions) are discussed. 2007 APA
Azevedo, Daniel Camara; Melo, Raphael Marques; Alves Corrêa, Ricardo Vidal; Chalmers, Gordon
2011-08-01
The purpose of this study was to compare the acute effect of the contract-relax (CR) stretching technique on knee active range of motion (ROM) using target muscle contraction or an uninvolved muscle contraction. pre-test post-test control experimental design. Clinical research laboratory. Sixty healthy men were randomly assigned to one of three groups. The Contract-Relax group (CR) performed a traditional hamstring CR stretch, the Modified Contract-Relax group (MCR) performed hamstring CR stretching using contraction of an uninvolved muscle distant from the target muscle, and the Control group (CG) did not stretch. Active knee extension test was performed before and after the stretching procedure. Two-way between-within analysis of variance (ANOVA) results showed a significant interaction between group and pre-test to post-test (p < 0.001). Post-hoc examination of individual groups showed no significant change in ROM for the CG (0.8°, p = 0.084), and a significant moderate increase in ROM for both the CR (7.0°, p < 0.001) and MCR (7.0°, p < 0.001) groups. ROM gain following a CR PNF procedure is the same whether the target stretching muscle is contracted, or an uninvolved muscle is contracted. Copyright © 2011 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Dodson, R. O., Jr.
1982-01-01
One of the objectives of the KC-135 Winglet Flight Research and Demonstration Program was to obtain experimental flight test data to verify the theoretical and wind tunnel winglet aerodynamic performance prediction methods. Good agreement between analytic, wind tunnel and flight test performance was obtained when the known differences between the tests and analyses were accounted for. The flight test measured fuel mileage improvements for a 0.78 Mach number was 3.1 percent at 8 x 10(5) pounds W/delta and 5.5 percent at 1.05 x 10(6) pounds W/delta. Correcting the flight measured data for surface pressure differences between wind tunnel and flight resulted in a fuel mileage improvement of 4.4 percent at 8 x 10(5) pounds W/delta and 7.2 percent at 1.05 x 10(6) pounds W/delta. The performance improvement obtained was within the wind tunnel test data obtained from two different wind tunnel models. The buffet boundary data obtained for the baseline configuration was in good agreement with previous established data. Buffet data for the 15 deg cant/-4 deg incidence configuration showed a slight improvement, while the 15 deg cant/-2 deg incidence and 0 deg cant/-4 deg incidence data showed a slight deterioration.