  1. Miniature personal UV solar dosimeter

    NASA Technical Reports Server (NTRS)

    Adams, R. R.; Macconochie, I. O.; Poole, B. D., Jr.

    1981-01-01

    Small light-powered meter measures accumulated radiation in ultraviolet or other selected regions. Practical advantages are device's low cost, small size, accuracy, and adaptability to specific wave-band measurements. Medical applications include detection of skin cancer, vitamin D production, and jaundice. Dosimeter also measures sunlight for solar energy designs, agriculture and meteorology, and monitors stability of materials and environmental and occupational lighting.

  2. Miniature personal UV solar dosimeter

    NASA Technical Reports Server (NTRS)

    Adams, R. R.; Macconochie, I. O.; Poole, B. D., Jr.

    1981-01-01

    Small light-powered meter measures accumulated radiation in ultraviolet or other selected regions. Practical advantages are device's low cost, small size, accuracy, and adaptability to specific wave-band measurements. Medical applications include detection of skin cancer, vitamin D production, and jaundice. Dosimeter also measures sunlight for solar energy designs, agriculture and meteorology, and monitors stability of materials and environmental and occupational lighting.

  3. MR-safe personal radiation dosimeters.

    PubMed

    Tchistiakova, E; Kim, A; Song, W Y; Pang, G

    2017-07-01

    Magnetic resonance imaging (MRI) is being rapidly integrated for cancer treatments-such systems are referred to as MRI-guided radiation therapy (MRIgRT). As the magnet of an MRI scanner is always on, the presence of a strong static magnetic field from the MRI scanner during radiotherapy delivery presents new challenges. One of the challenges is that a personal radiation dosimeter used to estimate the radiation dose deposited in an individual wearing the device must be MR-safe. No such devices, however, are currently available. In this work we first modified an existing personal dosimeter (by removing a metal clip) to make it MR-safe and then investigated potential effects of magnetic field on dosimeter readings, i.e., optically stimulated luminescent dosimeter (OSLD) readings. We found that the effect of magnetic field on OSLD sensitivity was within radiation protection tolerance levels. OSLD personal dosimeters can be directly used in conjunction with MRIgRT radiation protection purposes. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  4. Evaluation of a Colorimetric Personal Dosimeter for Nitrogen Oxide.

    ERIC Educational Resources Information Center

    Diamond, Philip

    A personal colorimetric dosimeter for nitrogen dioxide was developed. Tests were performed to determine the response of these strips to various concentrations of NO2. The dosimeter strips were satisfactory for approximate determinations of total exposure (concentration + time) of nitrogen dioxide. The total exposure was calculated in terms of time…

  5. Evaluation of a Colorimetric Personal Dosimeter for Nitrogen Oxide.

    ERIC Educational Resources Information Center

    Diamond, Philip

    A personal colorimetric dosimeter for nitrogen dioxide was developed. Tests were performed to determine the response of these strips to various concentrations of NO2. The dosimeter strips were satisfactory for approximate determinations of total exposure (concentration + time) of nitrogen dioxide. The total exposure was calculated in terms of time…

  6. Personal noise dosimeters: accuracy and reliability in varied settings.

    PubMed

    Cook-Cunningham, Sheri Lynn

    2014-01-01

    This study investigated the accuracy, reliability, and characteristics of three brands of personal noise dosimeters (N = 7 units) in both pink noise (PN) environments and natural environments (NEs) through the acquisition of decibel readings, Leq readings and noise doses. Acquisition periods included repeated PN conditions, choir room rehearsals and participant (N = 3) Leq and noise dosages procured during a day in the life of a music student. Among primary results: (a) All dosimeters exhibited very strong positive correlations for PN measurements across all instruments; (b) all dosimeters were within the recommended American National Standard Institute (ANSI) SI.25-1991 standard of ±2 dB (A) of a reference measurement; and (c) all dosimeters were within the recommended ANSI SI.25-1991 standard of ±2 dB (A) when compared with each other. Results were discussed in terms of using personal noise dosimeters within hearing conservation and research contexts and recommendations for future research. Personal noise dosimeters were studied within the contexts of PN environments and NEs (choral classroom and the day in the life of collegiate music students). This quantitative study was a non-experimental correlation design. Three brands of personal noise dosimeters (Cirrus doseBadge, Quest Edge Eg5 and Etymotic ER200D) were tested in two environments, a PN setting and a natural setting. There were two conditions within each environment. In the PN environment condition one, each dosimeter was tested individually in comparison with two reference measuring devices (Ivie and Easera) while PN was generated by a Whites Instrument PN Tube. In condition two, the PN procedures were replicated for longer periods while all dosimeters measured the sound levels simultaneously. In the NE condition one, all dosimeters were placed side by side on a music stand and recorded sound levels of choir rehearsals over a 7-h rehearsal period. In NE, condition two noise levels were measured during

  7. A critical assessment of two types of personal UV dosimeters.

    PubMed

    Seckmeyer, Gunther; Klingebiel, Marcus; Riechelmann, Stefan; Lohse, Insa; McKenzie, Richard L; Liley, J Ben; Allen, Martin W; Siani, Anna-Maria; Casale, Giuseppe R

    2012-01-01

    Doses of erythemally weighted irradiances derived from polysulphone (PS) and electronic ultraviolet (EUV) dosimeters have been compared with measurements obtained using a reference spectroradiometer. PS dosimeters showed mean absolute deviations of 26% with a maximum deviation of 44%, the calibrated EUV dosimeters showed mean absolute deviations of 15% (maximum 33%) around noon during several test days in the northern hemisphere autumn. In the case of EUV dosimeters, measurements with various cut-off filters showed that part of the deviation from the CIE erythema action spectrum was due to a small, but significant sensitivity to visible radiation that varies between devices and which may be avoided by careful preselection. Usually the method of calibrating UV sensors by direct comparison to a reference instrument leads to reliable results. However, in some circumstances the quality of measurements made with simple sensors may be over-estimated. In the extreme case, a simple pyranometer can be used as a UV instrument, providing acceptable results for cloudless skies, but very poor results under cloudy conditions. It is concluded that while UV dosimeters are useful for their design purpose, namely to estimate personal UV exposures, they should not be regarded as an inexpensive replacement for meteorological grade instruments. © 2011 Wiley Periodicals, Inc. Photochemistry and Photobiology © 2011 The American Society of Photobiology.

  8. [Estimation of personal dose based on the dependent calibration of personal dosimeters in interventional radiology].

    PubMed

    Mori, Hiroshige; Koshida, Kichiro; Ichikawa, Katsuhiro

    2007-08-20

    The purpose of present study is, in interventional radiology (IVR), to elucidate the differences between each personal dosimeter, and the dependences and calibrations of area or personal dose by measurement with electronic dosimeters in particular. We compare space dose rate distributions measured by an ionization survey meter with the value measured by personal dosimeter: an optically stimulated luminescence, two fluoroglass, and two electronic dosimeters. Furthermore, with electronic dosimeters, we first measured dose rate, energy, and directional dependences. Secondly, we calibrated the dose rate measured by electronic dosimeters with the results, and estimated these methods with coefficient of determination and Akaike's Information Criterion (AIC). The results, especially in electronic dosimeters, revealed that the dose rate measured fell by energy and directional dependences. In terms of methods of calibration, the method is sufficient for energy dependence, but not for directional dependence, because of the lack of stable calibration. This improvement poses a question for the future. The study suggested that these dependences of the personal dosimeter must be considered when area or personal dose is estimated in IVR.

  9. NASA Crew Personal Active Dosimeters (CPADs): Leveraging Novel Terrestrial Personal Radiation Monitoring Capabilities for Space Exploration

    NASA Technical Reports Server (NTRS)

    Leitgab, Martin; Semones, Edward; Lee, Kerry

    2016-01-01

    The NASA Space Radiation Analysis Group (SRAG) is developing novel Crew Personal Active Dosimeters (CAPDs) for upcoming crewed space exploration missions and beyond. To reduce the resource footprint of the project a COTS dosimeter base is used for the development of CPADs. This base was identified from evaluations of existing COTS personal dosimeters against the concept of operations of future crewed missions and tests against detection requirements for radiation characteristic of the space environment. CPADs exploit operations efficiencies from novel features for space flight personal dosimeters such as real-time dose feedback, and autonomous measuring and data transmission capabilities. Preliminary CPAD design, results of radiation testing and aspects of operational integration will be presented.

  10. Response of personal noise dosimeters to continuous and impulse-like signals

    NASA Astrophysics Data System (ADS)

    Evans, D. J.; Flynn, D. R.; Nedzelnitsky, V.; Burnett, E. D.

    1991-06-01

    A study of the capabilities of noise dosimeters to measure personal exposure to time varying and impulse-like noises was carried out. Ten commercial noise dosimeters were obtained. A laboratory reference noise dosimeter was constructed to provide a demonstrably accurate basis with which to compare the commercial noise dosimeters. Each commercial dosimeter, when ordered from the manufacturer, was specified to have a threshold A-weighted sound level of 80 dB, a criterion sound level of 90 dB, and an exchange rate of 5 dB and/or 3 dB. The performance of the commercial dosimeters was compared with theory and with results obtained from the reference dosimeter. Except in a few isolated cases, the commercial dosimeters were in general agreement with the performance specification of the appropriate American National Standard and with the Occupational Safety and Health Administration (OSHA) regulations.

  11. [Is it really not possible to use electronic personal dosimeters in clinical exposure situations?].

    PubMed

    Borowski, M; Poppe, B; Looe, H K; von Boetticher, H

    2010-09-01

    Due to significant measuring inaccuracies that can occur under certain conditions, the use of electronic personal dosimeters in statutory measurements in X-ray diagnostics is currently legally restricted. The present study investigates the clinically relevant situations in which measurement errors of more then 20 % can be anticipated. Four series of experiments were made, comparing the results of the electronic personal dosimeter EPD Mk2.3 to those of reference dosimeters (TLDs and diagnostic dosimeters). On the one hand, personal doses have been determined in the routine operation of controlled areas in various departments. On the other hand, measurements on phantoms have been conducted in extreme but realistic situations under radiation protection. Experiments were conducted in unweakened scattered radiation as well as in unattenuated and attenuated direct radiation. The tested electronic personal dosimeter type meets the requirements regarding measurement accuracy for "official" personal dosimeters in all of the examined clinically relevant scattered radiation fields. Only if exposed to radiation directly, an underestimation of the dose can occur and can be greater than 90 %. In the range of scattered radiation of diagnostic X-ray equipment, even in pulsed fields, the use of electronic personal dosimeters is reasonable. Considerable measurement errors can only arise in radiation fields that are not realistic under regular conditions and even in connection with most accidents. Georg Thieme Verlag KG Stuttgart, New York.

  12. Performance Testing Of Selected Types of Electronic Personal Dosimeters in X- and Gamma Radiation Fields.

    PubMed

    Kržanović, Nikola; Živanović, Miloš; Ciraj-Bjelac, Olivera; Lazarević, Đorđe; Ćeklić, Sandra; Stanković, Srboljub

    2017-10-01

    Electronic personal dosimeters (EPDs) are increasingly being used alongside conventional thermoluminescent dosimeters to measure the dose of legal record in terms of personal dose equivalent. Therefore, it is of great importance to execute performance tests of these dosimeters in photon fields of various energies and at various angles of incidence. This testing is done in order to simulate the behavior of these dosimeters in realistic multidirectional polyenergetic ionizing radiation fields. Tests of accuracy, linearity, energy response, and angular response have been performed on 10 EPDs from multiple manufacturers. Various radiation qualities have been used in the energy range from 33 keV to 1.33 MeV and for angles of incidence 0° to 80°. This research proves that many of the EPDs tested performed according to the manufacturer's specifications and the requirements of the international standards regarding personal dosimetry.

  13. A new electronic neutron dosimeter (END) for reliable personal dosimetry

    NASA Astrophysics Data System (ADS)

    Ing, H.; Cousins, T.; Andrews, H. R.; Machrafi, R.; Voevodskiy, A.; Kovaltchouk, V.; Clifford, E. T. H.; Robins, M.; Larsson, C.; Hugron, R.; Brown, J.

    2008-04-01

    Tests of existing electronic neutron dosimeters by military and civilian groups have revealed significant performance limitations. To meet the operational requirements of emergency response personnel to a radiological/nuclear incident as well as those in the nuclear industry, a new END has been developed. It is patterned after a unique commercial neutron spectral dosemeter known as the N-probe. It uses a pair of small special scintillators on tiny photomultiplier tubes. Special electronics were designed to minimize power consumption to allow for weeks of operation on a single charge. The size, performance, and data analysis for the END have been designed to meet/exceed international standards for electronic neutron dosimeters. Results obtained with the END prototype are presented.

  14. Description and application of a personal ultraviolet dosimeter: a review of preliminary studies.

    PubMed

    Challoner, A V; Corbett, M F; Davis, A; Diffey, B L; Leach, J F; Magnus, I A

    1978-12-01

    Preliminary work on a dosimeter suitable for measuring UVR exposure on individual persons is described. It is based on the use of polysulfone film which, on exposure, shows a change in absorbance that is determined spectrophotometrically. The results of studies of groups of persons with vastly different degrees of solar exposure, e.g., outdoor and indoor workers and geriatric patients, and psychiatric patients with photosensitivity from phenothiazine drugs are presented. We consider the dosimeter may also be suitable for epidemiologic studies in sunlight-induced skin cancer.

  15. Compliance and data reliability in sun exposure studies with diaries and personal, electronic UV dosimeters.

    PubMed

    Thieden, Elisabeth; Philipsen, Peter A; Wulf, Hans Christian

    2006-04-01

    Skin cancer risk estimations are based on sun exposure data. However, the reliability of collected data in personal ultraviolet (UV) dosimeters studies has not previously been validated. We aimed at investigating the data reliability and subject compliance in a study of sun exposure behaviour among 407 subjects (age range, 4-68 years) during 54 943 days based on time-stamped personal UV dosimeter readings and diary records. By comparing diary records and UV dosimeter readings on a daily basis, we investigated subject compliance, total sun exposure record, reasons for non-responding along with rates of diary completing errors. Efforts to improve compliance were described. The subject compliance rate was median 93.5% (percent days where the diary was completed and the UV dosimeter was worn). The total sun exposure record rate was median 84.1% (percent of participation days with both UV dosimeter and diary records and where the UV dosimeter was worn). Children, adolescents and golfers had lower sun exposure record rates than the rest of the groups (P<0.05). No significant difference was found between males and females (P=0.15). The 17 non-responders were 10 children, three adolescents, one sun worshipper, two golfers and one gardener. Correctable diary completing mistakes were found in 3.1% of the days. Children made more completing mistakes than adults (P=0.001). The average estimated error rate was 3.3% and was higher for children (6.3%) and adolescents (3.6%) than the adult groups (2.4%). High subject compliance rate and data reliability were obtained because the investigators were service minded but persistent, offering dosimeter maintenance service within 24 h and scrutinized data for errors and mistakes.

  16. Miniature personal electronic UVR dosimeter with erythema response and time-stamped readings in a wristwatch.

    PubMed

    Heydenreich, Jakob; Wulf, Hans Christian

    2005-01-01

    Personal ultraviolet radiation (UVR) dosimetry is important because sunlight is the most important risk factor for skin cancer and a risk factor for some eye diseases and immunosuppression and related disorders. Integrating devices, such as polysulphone film dosimeters, are generally used. To measure the exact dose at specific times, we have developed a personal electronic UVR dosimeter that makes time-stamped measurements. It has a sensor with an erythema action spectrum response and a linear sensitivity (dose-response) with no offset. The sensor has cosine response, and the dosimeter can cope with environmental conditions such as rain, temperature and dirt. It can be programmed to measure with different time intervals and save the average of a specified number of measurements in the memory that can store 32 000 time-stamped measurements. It is small (36 x 28 x 13 mm), weighs 14 g and can work for 4 months without maintenance. It is worn on the wrist, is equipped with a watch showing the time and may thus be used in large-scale studies. The sensitivity can change by 10% due to temperature changes from -5 to 40 degrees C. The UVR dosimeter sensitivity is 0.09 standard erythema doses (SED)/h and the difference in total received dose during 7 days between a Solar Light 501 UV-Biometer (186 SED) and our UVR dosimeter was 3% and the median difference in daily total dose was 2.2%. The dosimeter provides unique possibilities. Examples of personal UVR measurements, data calculations and how they can be interpreted are given.

  17. Simulation and test of a new albedo personal dosimeter for neutrons

    NASA Astrophysics Data System (ADS)

    Manfredotti, C.; Zanini, A.; Rollet, S.; Arman, G.

    1989-12-01

    A new personal dosimeter for neutrons, using three TLD 600s and one TLD 700 in a cadmium housing and detecting both incoming and albedo neutrons, has been designed, developed, tested and simulated by the code MORSE. Its response in the energy region between 10 -8 and 10 MeV is more similar to ICRP fluence-dose equivalent calibration factor behaviour with respect to previous albedo dosimeters, and particularly fast neutron tissue dose equivalents are less underestimated. Present data confirm that both accuracy and precision fulfil the International Commissions requests (NCR, NCRP, ANSI). Theory, simulation and experimental results obtained with a laboratory prototype are presented and discussed.

  18. On the response of electronic personal dosimeters in constant potential and pulsed x- ray beams

    NASA Astrophysics Data System (ADS)

    Guimarães, M. C.; Silva, C. R. E.; Oliveira, P. M. C.; da Silva, T. A.

    2016-07-01

    Electronic personal dosimeters (EPDs) based on solid state detectors have widely been used but some deficiencies in their response in pulsed radiation beams have been reported. Nowadays, there is not an international standard for pulsed x-ray beams for calibration or type testing of dosimeters. Irradiation conditions for testing the response of EPDs in both the constant potential and pulsed x-ray beams were established in CDTN. Three different types of EPDs were tested in different conditions in similar ISO and IEC x-ray qualities. Results stressed the need of performing additional checks before using EPDs in constant potential or pulsed x-rays.

  19. Improving the Success Rate of Delivering Annual Occupational Dosimetry Reports to Persons Issued Temporary External Dosimeters

    SciTech Connect

    Mallett, Michael Wesley

    2014-09-09

    Workers who are not routinely monitored for occupational radiation exposure at LANL may be issued temporary dosimeters in the field. Per 10CFR835 and DOE O 231.1A, the Laboratory's radiation protection program is responsible for reporting these results to the worker at the end of the year. To do so, the identity of the worker and their mailing address must be recorded by the delegated person at the time the dosimeter is issued. Historically, this data has not been consistently captured. A new online application was developed to record the issue of temporary dosimeters. The process flow of the application was structured such that: 1) the worker must be uniquely identified in the Lab's HR database, and 2) the mailing address of record is verified live time via a commercial web service, for the transaction to be completed. A COPQ savings (Type B1) of $96K/year is demonstrated for the new application.

  20. Considerations concerning the use of counting active personal dosimeters in pulsed fields of ionising radiation.

    PubMed

    Ambrosi, Peter; Borowski, Markus; Iwatschenko, Michael

    2010-06-01

    Active personal electronic dosimeters (APDs) exhibit limitations in pulsed radiation fields, which cannot be overcome without the use of new detection technology. As an interim solution, this paper proposes a method by which some conventional dosimeters can be operated in a way such that, based on the basic knowledge about the pulsed radiation field, any dosimetric failure of the dosimeter is signalised by the instrument itself. This method is not applicable to all combinations of APD and pulsed radiation field. The necessary requirements for the APD and for the parameters of the pulsed radiation field are given in the paper. Up to now, all such requirements for APDs have not been tested or verified in a type test. The suitability of the method is verified for the use of one APD used in two clinical pulsed fields.

  1. Determination of possible damage/degradation of the Sandia National Laboratories Personal Nuclear Accident Dosimeter (PNAD).

    SciTech Connect

    Potter, Charles Augustus; Ward, Dann C.

    2008-05-01

    This report describes the results of an inspection performed on the existing stock of SNL Personal Nuclear Accident Dosimeters (PNADs). The current stock is approximately 20 years old, and has not been examined since their initial acceptance. A small random sample of PNADs were opened (a destructive process) and the contents visually examined. Sample contents were not degraded and indicate that the existing stock of SNL PNADs is acceptable for continued use.

  2. SINGLE ANODE TRIPLE GEM TISSUE EQUIVALENT PROPORTIONAL COUNTER AS THE BASIS FOR A PERSONAL NEUTRON DOSIMETER.

    PubMed

    Seydaliev, M; Dubeau, J; Ali, F

    2017-04-28

    This paper reports on a tissue-equivalent proportional counter (TEPC) based on a triple gas electron multiplier structure, with a single pad readout, as a basis for a personal neutron dosimeter. Its dosimetric response was studied using the 252Cf neutron source at the Health Physics Generator Facility of the Canadian Nuclear Laboratories. Measured lineal energy spectra were found to be in agreement with numerical simulations performed with Monte Carlo N-Particle eXtended (MCNPX). Both simulations and measurements showed that the mean pathlength of secondary charged particles in the TEPC gas was best represented by the thickness of the drift region of the device. It was determined that the Cauchy Theorem, used to calculate the mean chord length in spherical and cylindrical TEPCs, overestimated the simulated mean chord length by nearly a factor of two. Important operational characteristics of the device were investigated, including gas gain, sensitivity and dosimetric response, as functions of tissue-equivalent gas pressure. This work demonstrates that the proposed design can serve as the basis for a personal neutron dosimeter device, which would satisfy the angular dosimetric response criteria of the personal dosimeter standard IEC61526. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Development of a high efficiency personal/environmental radon dosimeter using polycarbonate detectors.

    PubMed

    Taheri, M; Jafarizadeh, M; Baradaran, S; Zainali, Gh

    2006-12-01

    Passive radon dosimeters, based on alpha particle etched track detectors, are widely used for the assessment of radon exposure. These methods are often applied in radon dosimetry for long periods of time. In this research work, we have developed a highly efficient method of personal/environmental radon dosimetry that is based upon the detection of alpha particles from radon daughters, (218)Po and (214)Po, using a polycarbonate detector (PC). The radon daughters are collected on the filter surface by passing a fixed flow of air through it and the PC detector, placed at a specified distance from the filter, is simultaneously exposed to alpha particles. After exposure, the latent tracks on the detector are made to appear by means of an electrochemical etching process; these are proportional to the radon dose. The air flow rate and the detector-filter distance are the major factors that can affect the performance of the dosimeter. The results obtained in our experimental investigations have shown that a distance of 1.5 cm between the detector and the filter, an absorber layer of Al with a thickness of 12 microm and an air flow rate of 4 l min(-1) offer the best design parameters for a high efficiency radon dosimeter. Then, the designed dosimeter was calibrated against different values of radon exposures and the obtained sensitivity was found to be 2.1 (tracks cm(-2)) (kBq h m(-3))(-1). The most important advantages of this method are that it is reliable, fast and convenient when used for radon dose assessment. In this paper, the optimized parameters of the dosimeter structure and its calibration procedure are presented and discussed.

  4. State of the art of electronic personal dosimeters for neutrons

    NASA Astrophysics Data System (ADS)

    d'Errico, Francesco; Luszik-Bhadra, Marlies; Lahaye, Thierry

    2003-06-01

    Despite a widely recognised need, electronic devices for personal dosimetry of neutrons or mixed neutron-photon fields are still far less established than systems for photon or beta radiations. A large research project is in progress to evaluate different methods currently used or under development for electronic personal dosimetry in mixed neutron-photon fields. The study includes testing in calibration fields as well as in representative workplaces of the nuclear industry. This paper describes the commercial and laboratory systems under investigation and their response characteristics. These were determined so far with measurements using ISO standard monoenergetic beams up to 19 MeV at the PTB in Braunschweig, Germany.

  5. Design of an ultra low power CMOS pixel sensor for a future neutron personal dosimeter

    SciTech Connect

    Zhang, Y.; Hu-Guo, C.; Husson, D.; Hu, Y.

    2011-07-01

    Despite a continuously increasing demand, neutron electronic personal dosimeters (EPDs) are still far from being completely established because their development is a very difficult task. A low-noise, ultra low power consumption CMOS pixel sensor for a future neutron personal dosimeter has been implemented in a 0.35 {mu}m CMOS technology. The prototype is composed of a pixel array for detection of charged particles, and the readout electronics is integrated on the same substrate for signal processing. The excess electrons generated by an impinging particle are collected by the pixel array. The charge collection time and the efficiency are the crucial points of a CMOS detector. The 3-D device simulations using the commercially available Synopsys-SENTAURUS package address the detailed charge collection process. Within a time of 1.9 {mu}s, about 59% electrons created by the impact particle are collected in a cluster of 4 x 4 pixels with the pixel pitch of 80 {mu}m. A charge sensitive preamplifier (CSA) and a shaper are employed in the frond-end readout. The tests with electrical signals indicate that our prototype with a total active area of 2.56 x 2.56 mm{sup 2} performs an equivalent noise charge (ENC) of less than 400 e - and 314 {mu}W power consumption, leading to a promising prototype. (authors)

  6. Miniature Tissue Equivalent Proportional Counter dosimeter for active personal radiation monitoring of astronauts

    NASA Astrophysics Data System (ADS)

    Watson Huber, Aubrey

    The accurate measurement of spaceflight crew radiation exposure is of utmost importance. If onboard instrumentation shows that the pre-determined limit for radiation exposure has been met or exceeded during a mission, that mission can be greatly affected by the implementation of precautionary measures, or, in more extreme cases, the crew's health being negatively affected. Large active regional monitors determine real-time radiation risks of the crew during spaceflight, while small passive personal badges detect individual astronaut total exposure levels upon their return to Earth. At present, there are no personal active radiation dosimeters that can assess the continuous radiation risk to individual astronauts during spaceflight. Personal active radiation devices would be ideal for current operations in low-Earth orbit (LEO), as well as upcoming extravehicular activities on the Moon, Mars, or other planetary bodies. This project focused on the miniaturization of the Tissue Equivalent Proportional Counters (TEPCs) presently being utilized on the International Space Station (ISS) and Space Shuttle, enabling them to become personal crew dosimeters. The miniaturized TEPC prototype design has dimensions of 7.6 x 10.1 x 2.54 cm (3 x 4 x 1 in). It is composed of a 3 x 4 array of 1.27 cm (0.5 in) spherical detectors for measurements equivalent to a 4.39 cm (1.73 in) spherical detector, with an additional standalone sphere of diameter 1.27 cm (0.5 in) for taking measurements in high-flux environments. The detector simulates a tissue-equivalent diameter of 2 microns, is sensitive to lineal energies of 0.3 -- 1000 keV/micron, and can measure charged particles and neutrons ranging from 0.01 -- 100 mGy/hr.

  7. Exposure of arctic field scientists to ultraviolet radiation evaluated using personal dosimeters.

    PubMed

    Cockell, C S; Scherer, K; Horneck, G; Rettberg, P; Facius, R; Gugg-Helminger, A; Driscoll, C; Lee, P

    2001-10-01

    During July 2000 we used an electronic personal dosimeter (X-2000) and a biological dosimeter (Deutsches Zentrum für Luft- und Raumfahrt: Biofilm) to characterize the UV radiation exposure of arctic field scientists involved in biological and geological fieldwork. These personnel were working at the Haughton impact structure on Devon Island (75 degrees N) in the Canadian High Arctic under a 24 h photoperiod. During a typical day of field activities under a clear sky, the total daily erythemally weighted exposure, as measured by electronic dosimetry, was up to 5.8 standard erythemal dose (SED). Overcast skies (typically 7-8 okta of stratus) reduced exposures by a mean of 54%. We estimate that during a month of field activity in July a typical field scientist at this latitude could potentially receive approximately 80 SED to the face. Because of body movements the upper body was exposed to a UV regimen that often changed on second-to-second time-scales as assessed by electronic dosimetry. Over a typical 10 min period on vehicle traverse, we found that erythemal exposure could vary to up to 87% of the mean exposure. Time-integrated exposures showed that the type of outdoor field activities in the treeless expanse of the polar desert had little effect on the exposure received. Although absolute exposure changed in accordance with the time of day, the exposure ratio (dose received over horizontal dose) did not vary much over the day. Under clear skies the mean exposure ratio was 0.35 +/- 0.12 for individual activities at different times of the day assessed using electronic dosimetry. Biological dosimetry showed that the occupation was important in determining daily exposures. In our study, scientists in the field received an approximately two-fold higher dose than individuals, such as medics and computer scientists, who spent the majority of their time in tents.

  8. Personal Active Dosimeter for Space: the Light Observer for Radiation Environment (LORE) project

    NASA Astrophysics Data System (ADS)

    Narici, Livio

    Long permanence in space outside the protections of the Earth magnetic shield and atmosphere (during long journeys, and on the Moon or/and Mars) requires a careful monitoring of absorbed doses by each astronaut. This is of paramount importance for transient and cumulative effects mostly due to Solar Particle Events. Alarming features and the possibility of monitoring absorbed dose also discriminating the kind of incoming radiation will be needed. Stemming from our large experience in detector building, in modelling, in designing of the supporting electronic, from our payloads flown on satellites, MIR Station and ISS (Nina, Mita, SilEye, SilEye2, Alteino, Pamela, ALTEA) we are developping a personal active dosimeter with alarming and wireless features. The goal is a small object able to measure charged and neutral ionizing radiation (the possibility to insert a miniaturized gamma detector will be investigated) The device will feature portability (cigarette-box dimensions, rechargeable batteries), sensitivity to ions (H to above Fe), to hard X-rays, and possibly to gamma with the ability to detect and count neutrons. Flash memories should contain pre loaded tables and the real Time code to perform the real time operations and risk thresholds so to activate an alarm if/when needed. Whenever in range, the device will connect wirelessly to the main computer and send there the raw and pre-analyzed data for a complete monitoring and possible more sophisticated analyses. The two major novelties and challenges in this project are the miniaturization of the device, including the firmware, and the definition of the transfer function and of its uncertainties, linking measured data with real flux data. This will require the proper balancing among size, radiation discrimination ability and uncertainty minimization.

  9. Characterization of the energy response and backscatter contribution for two electronic personal dosimeter models.

    PubMed

    Meier, Joseph; Kappadath, S Cheenu

    2015-11-08

    We characterized the energy response of personal dose equivalent (Hp(10) in mrem) and the contribution of backscatter to the readings of two electronic personal dosimeter (EPD) models with radionuclides commonly used in a nuclear medicine clinic. The EPD models characterized were the RADOS RAD-60R, and the SAIC PD-10i. The experimental setup and calculation of EPD energy response was based on ANSI/HPS N13.11-2009. Fifteen RAD-60R and 2 PD-10i units were irradiated using (99m)Tc, (131)I, and (18)F radionuclides with emission energies at 140 keV, 364 keV, and 511 keV, respectively. At each energy, the EPDs output in Hp(10) [mrem] were recorded with 15 inch thick PMMA to simulate backscatter form the torso. Simultaneous free-in-air exposure rate measurements were also performed using two Victoreen ionization survey meters to calculate the expected EPD Hp(10) values per ANSI/HPS N13.11-2009. The energy response was calculated by taking the ratio of the EPD Hp(10) readings with the expected Hp(10) readings and a two-tailed z-test was used to determine the significance of the ratio deviating away from unity. The contribution from backscatter was calculated by taking the ratio of the EPD Hp(10) readings with and without backscatter material. A paired, two-tailed t-test was used to determine the significance of change in EPD Hp(10) readings. The RAD-60R mean energy response at 140 keV was 0.85, and agreed to within 5% and 11% at 364 and 511 keV, respectively. The PD-10i mean energy response at 140 keV was 1.20, and agreed to within 5% at 364 and 511 keV, respectively. On average, in the presence of acrylic, RAD-60R values increased by 32%, 12%, and 14%, at 140, 364, and 511 keV, respectively; all increases were statistically significant. The PD-10i increased by 25%, 19%, and 10% at 140 keV, 364 keV, and 511 keV, respectively; however, only the 140 keV measurement was statistically significant. Although both EPD models performed within the manufacturers' specifications of

  10. Radiation dosimeters

    DOEpatents

    Hoelsher, James W.; Hegland, Joel E.; Braunlich, Peter F.; Tetzlaff, Wolfgang

    1992-01-01

    Radiation dosimeters and dosimeter badges. The dosimeter badges include first and second parts which are connected to join using a securement to produce a sealed area in which at least one dosimeter is held and protected. The badge parts are separated to expose the dosimeters to a stimulating laser beam used to read dose exposure information therefrom. The badge is constructed to allow automated disassembly and reassembly in a uniquely fitting relationship. An electronic memory is included to provide calibration and identification information used during reading of the dosimeter. Dosimeter mounts which reduce thermal heating requirements are shown. Dosimeter constructions and production methods using thin substrates and phosphor binder-layers applied thereto are also taught.

  11. Realistic approach to estimate lens doses and cataract radiation risk in cardiology when personal dosimeters have not been regularly used.

    PubMed

    Vañó, Eliseo; Fernández, José M; Sánchez, Roberto M; Dauer, Lawrence T

    2013-10-01

    Interventional fluoroscopic guided cardiac procedures lead to radiation exposure to the lenses of the eyes of cardiologists, which over time may be associated with an increased risk of cataracts. This study derives radiation doses to the lens of the eye in cardiac catheterization laboratories from measurements of individual procedures to allow for estimates of such doses for those cases when personal dosimeters have not been used regularly. Using active electronic dosimeters at the C-arm (at 95 cm from the isocenter), scatter radiation doses have been measured for cardiac procedures and estimated radiation doses to the lenses of the cardiologists for different groups of procedures (diagnostic, PTCAs, and valvular). Correlation factors with kerma area product included in the patient dose reports have been derived. The mean, median, and third quartile scatter dose values per procedure at the C-arm for 1,969 procedures were 0.99, 0.78 and 1.25 mSv, respectively; for coronary angiography, 0.51, 0.45, and 0.61 mSv, respectively; for PTCAs, 1.29, 1.07, and 1.56 mSv; and for valvular procedures, 1.64, 1.45, and 2.66 mSv, respectively. For all the procedures, the ratio between the scatter dose at the C-arm and the kerma area product resulted in between 10.3-11.3 μSv Gy cm. The experimental results of this study allow for realistic estimations of the dose to the lenses of the eyes from the workload of the cardiologists and from the level of use of radiation protection tools when personal dosimeters have not been regularly used.

  12. Electronic UV dosimeters.

    PubMed

    Wulf, H C; Gniadecka, M

    1996-08-01

    The pathogenic role of ultraviolet (UV) in the development of skin cancer, skin ageing and immunosuppression makes it important to monitor human exposure to UV radiation. In a previous study we constructed UVB and UVC dosimeters based on a thermoluminescent phenomenon induced by UV in CaF2 :Dy and CaF2 crystals. However, these dosimeters were insensitive to UVA radiation and readout was time-consuming. In the present study we aimed to develop an electronic dosimeter suitable for UVA, UVB and UVC. The principle of this dosimeter is a measure of accumulated electric current induced by UV on a photodetector. Electric current induced by UV on a photodetector was accumulated in a Plessey's E-cell coulometer. A special reading device was constructed to quantify total charge of the coulometer. Sensitivity for UVA, UVB and UVC was achieved by the use of appropriate filters in front of the photodetector. The sensitivity of the electronic dosimeter increased with increasing wavelength of UV radiation; therefore, in UVB and UVC dosimeters the use of amplifiers was necessary. A linear response to UVA, UVB and UVC was achieved. Dosimeters with a linear response to increasing doses of UVA, UVB and UVC have been constructed for personal monitoring of UV exposure.

  13. Effect of the Scattering Radiation in Air and Two Type of Slap Phantom between PMMA and the ISO Water Phantom for Personal Dosimeters Calibration

    NASA Astrophysics Data System (ADS)

    Kamwang, N.; Rungseesumran, T.; Saengchantr, D.; Monthonwattana, S.; Pungkun, V.

    2017-06-01

    The calibration of personal dosimeter to determine the quantities of the personal dose equivalent, Hp(d), is required to be placed on a suitable phantom in order to provide a reasonable approximation to the radiation backscattering properties as equivalent as part of body. The dosimeter which is worn on the trunk usually calibrated with slap phantom which recommended in ICRU 47 with dimension of 30 cm (w) x 30 cm (h) x 15 cm (t) PMMA slab phantom to achieve uniformity in calibration procedures, on the other hand the International Organization for Standardization (ISO), ISO 4037-3, proposed the ISO water slap phantom, with PMMA walls, same dimension but different wall thickness (front wall 2.5 mm and other side wall 10 mm thick) and fill with water. However, some laboratories are still calibrating a personal dosimeter in air in term of ambient dose equivalent, H*(d). This research study the effect of the scattering radiation in two type of those slap phantoms and in air, to calibrate two type of OSL (XA and LA) and electronic personal dosimeters. The X-ray and Cs-137 radiation field with the energy range from 33 to 662 keV were used. The results of this study will be discussed.

  14. Electromagnetic malfunction of semiconductor-type electronic personal dosimeters caused by access control systems for radiation facilities.

    PubMed

    Deji, Shizuhiko; Ito, Shigeki; Ariga, Eiji; Mori, Kazuyuki; Hirota, Masahiro; Saze, Takuya; Nishizawa, Kunihide

    2006-08-01

    High frequency electromagnetic fields in the 120 kHz band emitted from card readers for access control systems in radiation control areas cause abnormally high and erroneous indicated dose readings on semiconductor-type electronic personal dosimeters (SEPDs). All SEPDs malfunctioned but recovered their normal performance by resetting after the exposure ceased. The minimum distances required to prevent electromagnetic interference varied from 5.0 to 38.0 cm. The electric and magnetic immunity levels ranged from 35.1 to 267.6 V m(-1) and from 1.0 to 16.6 A m(-1), respectively. Electromagnetic immunity levels of SEPDs should be strengthened from the standpoint of radiation protection.

  15. Wristwatch dosimeter

    DOEpatents

    Wolf, M.A.; Waechter, D.A.; Umbarger, C.J.

    1986-08-26

    The disclosure is directed to a wristwatch dosimeter utilizing a CdTe detector, a microprocessor and an audio and/or visual alarm. The dosimeter is entirely housable with a conventional digital watch case having an additional aperture enabling the detector to receive radiation. 10 figs.

  16. Wristwatch dosimeter

    DOEpatents

    Wolf, Michael A.; Waechter, David A.; Umbarger, C. John

    1986-01-01

    The disclosure is directed to a wristwatch dosimeter utilizing a CdTe detector, a microprocessor and an audio and/or visual alarm. The dosimeter is entirely housable with a conventional digital watch case having an additional aperture enabling the detector to receive radiation.

  17. Personal dosimetry of exposure to mobile telephone base stations? An epidemiologic feasibility study comparing the Maschek dosimeter prototype and the Antennessa SP-090 system.

    PubMed

    Radon, Katja; Spegel, Hedwig; Meyer, Nicole; Klein, Jerome; Brix, Jutta; Wiedenhofer, Arno; Eder, Heinrich; Praml, Georg; Schulze, Anja; Ehrenstein, Vera; von Kries, Rüdiger; Nowak, Dennis

    2006-01-01

    The aim of our study was to test the feasibility and reliability of personal dosimetry. Twenty-four hour exposure assessment was carried out in 42 children, 57 adolescents, and 64 adults using the Maschek dosimeter prototype. Self-reported exposure to mobile phone frequencies were compared with the dosimetry results. In addition, dosimetry readings of the Maschek device and those of the Antennessa DSP-090 were compared in 40 subjects. Self-reported exposures were not associated with dosimetry readings. The measurement results of the two dosimeters were in moderate agreement (r(Spearman) = 0.35; P = .03). Personal dosimetry for exposure to mobile phone base station might be feasible in epidemiologic studies. However, the consistency seems to be moderate.

  18. RADIATION DOSIMETER

    DOEpatents

    Balkwell, W.R. Jr.; Adams, G.D. Jr.

    1960-05-10

    An improvement was made in the determination of amounts of ionizing radiation, particularly low-energy beta particles of less than 1000 rad total dose by means of fluid-phase dosimeter employing a stabilized-- sensitized ferrous-ferric colorimetric system in a sulphuric acid medium. The improvement in the dosimeter consists of adding to the ferrous-ferric system in concentrations of 10/sub -2/ to 10/sup -4/M an organic compound having one or more carboxylic or equivalent groups, such compounds being capable of chelating or complexing the iron ions in the solution. Suitable sensitizing and stabilizing agents are benzoic, phthalic, salicylic, malonic, lactic, maleic, oxalic, citric, succinic, phenolic tartaric, acetic, and adipic acid, as well as other compounds which are added to the solution alone or in certain combinations. As in conventional fluid-phase dosimeters, the absorbed dosage is correlated with a corresponding change in optical density at particular wavelengths of the solution.

  19. PERSONNEL DOSIMETER

    DOEpatents

    Birkhoff, R.D.; Hubbell, H.H. Jr.; Johnson, R.M.

    1959-02-24

    A personnel dosimeter sensitive to both gamma and beta radiation is described. The dosimeter consists of an electrical conductive cylinder having a wall thickness of substantially 7 milligrams per square centimeter and an electrode disposed axially within the cylinder and insulated therefrom to maintain a potential impressed between the electrode and the cylinder. A cylindrical perforated shield provided with a known percentage of void area is disposed concentrically about the cylinder. The shield is formed of a material which does not contain more than 15 percent of an element higher than atomic weight 13. The dose actually received is at most the gamma dose plus the beta dose indicated by discharge of the dosimeter divided by the known percentage.

  20. Feasibility of smartphone diaries and personal dosimeters to quantitatively study exposure to ultraviolet radiation in a small national sample.

    PubMed

    Køster, Brian; Søndergaard, Jens; Nielsen, Jesper B; Allen, Martin; Bjerregaard, Mette; Olsen, Anja; Bentzen, Joan

    2015-09-01

    In 2007, a national skin cancer prevention campaign was launched to reduce the UV exposure of the Danish population. To improve campaign evaluation a questionnaire validation using UV-dosimeters was initiated. To show the feasibility of dosimeters for national representative studies and of smartphones as a data collection tool. Participants were sent a dosimeter which they wore for 7 days, received a short diary questionnaire by text message each day and subsequently a longer questionnaire. Correlation between responses from questionnaire, smartphone diaries and dosimeters were examined. This study shows a 99.5% return rate (n = 205) of the dosimeters by ordinary mail and high response-rates for a smartphone questionnaire dairy. Correlation coefficients for outdoor-time reported through smartphones and dosimeters as average by week 0.62 (0.39-0.77), P < 0.001 (n = 40). Correlation coefficient for outdoor time estimated by questionnaire and dosimeters were 0.42 (0.11-0.64), P = 0.008. The subjective perception of the weather was the only covariate significantly influencing questionnaire estimates of actual outdoor exposure. We showed that dosimeter studies are feasible in national settings and that smartphones are a useful tool for monitoring and collecting UV behavior data. We found diary data reported on a daily basis through smartphones more strongly associated with actual outdoor time than questionnaire data. Our results demonstrate tools and possible considerations for executing a UV behavior questionnaire validation. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Passive dosimeters for nitrogen dioxide in personal/indoor air sampling: A review

    PubMed Central

    Yu, Chang Ho; Morandi, Maria T.; Weisel, Clifford P.

    2015-01-01

    Accurate measurement of nitrogen dioxide concentrations in both outdoor and indoor environments, including personal exposures, is a fundamental step for linking atmospheric nitrogen dioxide levels to potential health and ecological effects. The measurement has been conducted generally in two ways: active (pumped) sampling and passive (diffusive) sampling. Diffusion samplers, initially developed and used for workplace air monitoring, have been found to be useful and cost-effective alternatives to conventional pumped samplers for monitoring ambient, indoor and personal exposures at the lower concentrations found in environmental settings. Since the 1970s, passive samplers have been deployed for ambient air monitoring in urban and rural sites, and to determine personal and indoor exposure to NO2. This article reviews the development of NO2 passive samplers, the sampling characteristics of passive samplers currently available, and their application in ambient and indoor air monitoring and personal exposure studies. The limitations and advantages of the various passive sampler geometries (i.e., tube, badge, and radial type) are also discussed. This review provides researchers and risk assessors with practical information about NO2 passive samplers, especially useful when designing field sampling strategies for exposure and indoor/outdoor air sampling. PMID:18446185

  2. SU-E-I-57: Estimating the Occupational Eye Lens Dose in Interventional Radiology Using Active Personal Dosimeters Worn On the Chest

    SciTech Connect

    Omar, A; Marteinsdottir, M; Kadesjo, N; Fransson, A

    2015-06-15

    Purpose: To provide a general formalism for determination of occupational eye lens dose based on the response of an active personal dosimeter (APD) worn at chest level above the radiation protection apron. Methods: The formalism consists of three factors: (1) APD conversion factor converting the reading at chest level (APDchest) to the corresponding personal dose equivalent at eye level, (2) Dose conversion factor transferring the measured dose quantity, Hp(10), into a dose quantity relevant for the eye lens dose, (3) Correction factor accounting for differences in exposure of the eye(s) compared to the exposure at chest level (e.g., due to protective lead glasses).The different factors were investigated and evaluated based on phantom and clinical measurements performed in an x-ray angiography suite for interventional cardiology. Results: The eye lens dose can be conservatively estimated by assigning an appropriate numerical value to each factor entering the formalism that in most circumstances overestimates the dose. Doing so, the eye lens dose to the primary operator and assisting staff was estimated in this work as D-eye,primary = 2.0 APDchest and D-eye,assisting = 1.0 APDchest, respectively.The annual eye lens dose to three nurses and one cardiologist was estimated to be 2, 2, 2, and 13 mSv (Hp(0.07)), respectively, using a TLD dosimeter worn at eye level. In comparison, using the formalism and APDchest measurements, the respective doses were 2, 2, 2, and 16 mSv (Hp(3)). Conclusion: The formalism outlined in this work can be used to estimate the occupational eye lens dose from the response of an APD worn on the chest. The formalism is general and could be applied also to other types of dosimeters. However, the numerical value of the different factors may differ from those obtained with the APD’s used in this work due to differences in dosimeter properties.

  3. Composite material dosimeters

    DOEpatents

    Miller, Steven D.

    1996-01-01

    The present invention is a composite material containing a mix of dosimeter material powder and a polymer powder wherein the polymer is transparent to the photon emission of the dosimeter material powder. By mixing dosimeter material powder with polymer powder, less dosimeter material is needed compared to a monolithic dosimeter material chip. Interrogation is done with excitation by visible light.

  4. Composite material dosimeters

    DOEpatents

    Miller, Steven D.

    1996-01-01

    The present invention is a composite material containing a mix of dosimeter material powder and a polymer powder wherein the polymer is transparent to the photon emission of the dosimeter material powder. By mixing dosimeter material powder with polymer powder, less dosimeter material is needed compared to a monolithic dosimeter material chip. Interrogation is done with excitation by visible light.

  5. Thermoluminescence dosimeter

    DOEpatents

    Zendle, Robert

    1985-01-01

    A thermoluminescence dosimeter having a very small rate of decline of sensitivity during subsequent uses after heating is disclosed. The dosimeter includes a detector crystal and a glass enclosure in which the detector crystal is located. The glass enclosure is air tight and is filled with a super dry inert fill gas. The inert fill gas is nonreactive with the detector crystal when the detector crystal is heated to thermoluminescence. The fill gas is selected from the group consisting of air, nitrogen, and argon, suitable admixed with 5 to 25 percent helium. The detector crystal consists essentially of calcium fluoride. The fill gas is preferably contained at a subatmospheric pressure in the glass enclosure.

  6. Thermoluminescence dosimeter

    DOEpatents

    Zendle, R.

    1983-11-03

    A thermoluminescence dosimeter having a very small rate of decline of sensitivity during subsequent uses after heating is disclosed. The dosimeter includes a detector crystal and a glass enclosure in which the detector crystal is located. The glass enclosure is air tight and is filled with a super dry inert fill gas. The inert fill gas is nonreactive with the detector crystal when the detector crystal is heated to thermoluminescence. The fill gas is selected from the group consisting of air, nitrogen, and argon, suitable admixed with 5 to 25 percent helium. The detector crystal consists essentially of calcium fluoride. The fill gas is preferably contained at a subatmospheric pressure in the glass enclosure.

  7. Development of a dose algorithm for the modified panasonic UD-802 personal dosimeter used at three mile island

    SciTech Connect

    Miklos, J. A.; Plato, P.

    1988-01-01

    During the fall of 1981, the personnel dosimetry group at GPU Nuclear Corporation at Three Mile Island (TMI) requested assistance from The University of Michigan (UM) in developing a dose algorithm for use at TMI-2. The dose algorithm had to satisfy the specific needs of TMI-2, particularly the need to distinguish beta-particle emitters of different energies, as well as having the capability of satisfying the requirements of the American National Standards Institute (ANSI) N13.11-1983 standard. A standard Panasonic UD-802 dosimeter was modified by having the plastic filter over element 2 removed. The dosimeter and hanger consists of the elements with a 14 mg/cm/sup 2/ density thickness and the filtrations shown. The hanger on this dosimeter had a double open window to facilitate monitoring for low-energy beta particles. The dose algorithm was written to satisfy the requirements of the ANSI N13.11-1983 standard, to include /sup 204/Tl with mixtures of /sup 204/Tl with /sup 90/Sr//sup 90/Y and /sup 137/Cs, and to include 81- and 200-keV average energy X-ray spectra. Stress tests were conducted to observe the algorithm performance to low doses, temperature, humidity, and the residual response following high-dose irradiations. The ability of the algorithm to determine dose from the beta particles of /sup 147/Pm was also investigated.

  8. NOTE: Cell-phone interference with pocket dosimeters

    NASA Astrophysics Data System (ADS)

    Djajaputra, David; Nehru, Ramasamy; Bruch, Philip M.; Ayyangar, Komanduri M.; Raman, Natarajan V.; Enke, Charles A.

    2005-05-01

    Accurate reporting of personal dose is required by regulation for hospital personnel that work with radioactive material. Pocket dosimeters are commonly used for monitoring this personal dose. We show that operating a cell phone in the vicinity of a pocket dosimeter can introduce large and erroneous readings of the dosimeter. This note reports a systematic study of this electromagnetic interference. We found that simple practical measures are enough to mitigate this problem, such as increasing the distance between the cell phone and the dosimeter or shielding the dosimeter, while maintaining its sensitivity to ionizing radiation, by placing it inside a common anti-static bag.

  9. European Crew Personal Active Dosimeter (EuCPAD), a novel dosimetry system utilizing operational and scientific synergies for the benefit of humans in space

    NASA Astrophysics Data System (ADS)

    Straube, Ulrich; Berger, Thomas

    A significant expansion of Human presence in space can be recognized over the last decade. Not only the frequency of human space mission did rise, but also time in space, mission duration with extended flights lasting half a year or more are becoming "standard". Despite the challenges to human health and well-being are still significant, or may even increase with mission length and work density. Also radiation exposure in space remains one of the inevitable and dominating factors relevant to crew- health, -safety and therefore mission success. The radiation environment that the space crews are exposed to differs significantly as compared to earth. Exposure in flight exceed doses that are usually received by terrestrial radiation workers on ground. Expanding "medical" demands are not a solely characteristics of current and current and upcoming mission scenarios. Likewise the margins for what is understood as "efficient utilization" for the fully operational science platform ISS, are immense. Understanding, accepting and approaching these challenges ESA-HSO did choose a particular pass of implementation for one of their current developments. Exploiting synergies of research, science and medical operational aspects, the "European Crew Personal Active Dosimeter for Astronauts (EuCPAD)" development exactly addresses these circumstances. It becomes novel part of ESA Radiation Protection Initiative for astronauts. The EuCPAD project aims at the development and manufacturing of an active (powered) dosimeter system to measure astronaut's exposures, support risk assessment dose management by providing a differentiated data set. Final goal is the verification of the system capabilities for medical monitoring at highest standards. The EuCPAD consists of several small portable Personal Active Dosimeters (MU = Mobile Unitas) and a rack mounted docking station “Personal Storage Device (PSD)” for MU storage, data read out and telemetry. The PSD furthermore contains a Tissue

  10. Low and high dose measurement by Agfa personal monitoring film and FD-III-B badge dosimeter system.

    PubMed

    Mihai, F; Bercea, S; Stochioiu, A; Celarel, A; Udup, E; Tudor, I

    2010-01-01

    This paper presents the measurement of the dose equivalent Hp(10) to low (0.005-1) mSv and high (20-1000) mSv doses by exposure at (241)Am and (173)Cs radiation sources of the halide film with FB-III-D dosimeter system. Accuracy of measurements, standard error of the dose mean value (SEM) and some comments about ability to reread of dosimetric films were determined. A good accuracy was obtained over the important dose ranges. In the low dose range, under 0.1 mSv, the SEM values of the (241)Am doses, recorded on the film under plastic filter, are between -21.36% and +47.51%. For 0.1-500 mSv (137)Cs dose range the SEM values are from -9.55% to +7.24%.

  11. Fiber-type dosimeter with improved illuminator

    DOEpatents

    Fox, Richard J.

    1987-01-01

    A single-piece, molded plastic, Cassigrainian-type condenser arrangement is incorporated in a tubular-shaped personal pocket dosimeter of the type which combines an ionization chamber with an optically-read fiber electrometer to provide improved illumination of the electrometer fiber. The condenser routes incoming light from one end of the dosimeter tubular housing around a central axis charging pin assembly and focuses the light at low angles to the axis so that it falls within the acceptance angle of the electrometer fiber objective lens viewed through an eyepiece lens disposed in the opposite end of the dosimeter. This results in improved fiber illumination and fiber image contrast.

  12. Fiber-type dosimeter with improved illuminator

    DOEpatents

    Fox, R.J.

    1985-12-23

    A single-piece, molded plastic, Cassigrainian-type condenser arrangement is incorporated in a tubular-shaped personal pocket dosimeter of the type which combines an ionization chamber with an optically-read fiber electrometer to provide improved illumination of the electrometer fiber. The condenser routes incoming light from one end of the dosimeter tubular housing around a central axis charging pin assembly and focuses the light at low angles to the axis so that it falls within the acceptance angle of the electrometer fiber objective lens viewed through an eyepiece lens disposed in the opposite end of the dosimeter. This results in improved fiber illumination and fiber image contrast.

  13. Fundamentals of gel dosimeters

    NASA Astrophysics Data System (ADS)

    McAuley, K. B.; Nasr, A. T.

    2013-06-01

    Fundamental chemical and physical phenomena that occur in Fricke gel dosimeters, polymer gel dosimeters, micelle gel dosimeters and genipin gel dosimeters are discussed. Fricke gel dosimeters are effective even though their radiation sensitivity depends on oxygen concentration. Oxygen contamination can cause severe problems in polymer gel dosimeters, even when THPC is used. Oxygen leakage must be prevented between manufacturing and irradiation of polymer gels, and internal calibration methods should be used so that contamination problems can be detected. Micelle gel dosimeters are promising due to their favourable diffusion properties. The introduction of micelles to gel dosimetry may open up new areas of dosimetry research wherein a range of water-insoluble radiochromic materials can be explored as reporter molecules.

  14. People maintain their sun exposure behaviour in a 5-7-year follow-up study using personal electronic UVR dosimeters.

    PubMed

    Thieden, Elisabeth; Heydenreich, Jakob; Philipsen, Peter A; Wulf, Hans Christian

    2013-01-01

    The main purpose of this study was to investigate whether people change their sun behaviour over a period of 7 years. Thus 32 volunteers, who had all participated in earlier sun exposure studies in 1999-2001, were enrolled in a follow-up study in 2006. They were selected to represent a previous low, medium and high UVR exposure. They participated for mean 121 days (range 65-157 days) wearing a personal, electronic wrist-borne UVR dosimeter and completed sun exposure diaries. No statistically significant differences were seen from year to year in the estimated annual UVR dose, mean UVR dose per day or mean percentage of ambient UVR. However, there was a person effect showing that participants maintained a high or low UVR dose lifestyle over the years. In 2006 the 32 participants received an estimated annual mean UVR dose of 221 SED and a median dose of 154 SED (range 25-1337 SED), while they received a mean for the previous participation years (1999-2001) of 236 SED (median 153 SED, range 24-980 SED). The estimated annual UVR dose for each of the previous sun years and the estimated annual dose for 2006 correlated significantly (R(2) = 0.51; p < 0.0001). Sun risk behaviour, expressed as days sunbathing, did not change either. The participants thus seem to have maintained their sun exposure behaviour over a 5-7-year period.

  15. Deficiencies of active electronic radiation protection dosimeters in pulsed fields.

    PubMed

    Ankerhold, U; Hupe, O; Ambrosi, P

    2009-07-01

    Nowadays nearly all radiation fields used for X-ray diagnostics are pulsed. These fields are characterised by a high dose rate during the pulse and a short pulse duration in the range of a few milliseconds. The use of active electronic dosimeters has increased in the past few years, but these types of dosimeters might possibly not measure reliably in pulsed radiation fields. Not only personal dosimeters but also area dosimeters that are used mainly for dose rate measurements are concerned. These cannot be substituted by using passive dosimeter types. The characteristics of active electronic dosimeters determined in a continuous radiation field cannot be transferred to those in pulsed fields. Some provisional measurements with typical electronic dosimeters in pulsed radiation fields are presented to reveal this basic problem.

  16. Pocket radiation dosimeter--dosimeter charger assembly

    DOEpatents

    Manning, Frank W.

    1984-01-01

    This invention is a novel pocket-type radiation dosimeter comprising an electrometric radiation dosimeter and a charging circuit therefor. The instrument is especially designed to be amenable to mass production, to have a long shelf life, and to be compact, lightweight, and usable by the layman. The dosimeter proper may be of conventional design. The charging circuit includes a shake-type electrostatic generator, a voltage doubler for integrating generator output voltages of one polarity, and a switch operated by an external permanent magnet.

  17. Pocket radiation dosimeter: dosimeter charger assembly

    DOEpatents

    Manning, F.W.

    1982-03-17

    This invention is a novel pocket-type radiation dosimeter comprising an electrometric radiation dosimeter and a charging circuit therefor. The instrument is especially designed to be amenable to mass production, to have a long shelf life, and to be compact, lightweight, and usable by the layman. The dosimeter proper may be of conventional design. The charging circuit includes a shake-type electrostatic generator, a voltage doubler for integrating generator output voltages of one polarity, and a switch operated by an external permanent magnet.

  18. The Mobile Dosimetric Telescope (MDT) - Development of a small size active personal dosimeter for application at high altitudes and onboard the International Space Station

    NASA Astrophysics Data System (ADS)

    Ritter, Birgit; Berger, Thomas; Reitz, Guenther; Burmeister, Soenke; Heber, Bernd; Marsalek, Karel

    2012-07-01

    The radiation environment in space poses one of the main health risks for long duration human missions as it differs significantly from the natural radiation environment on Earth. Therefore, it is essential to monitor the properties of the radiation field in such environments. The aim of this work is to develop a small size battery driven personal dosimeter, based on silicon detector technology. Two silicon detectors are arranged in a telescope configuration, which allows the measurement of the ionizing constituents of the field and partially of the neutral contribution to the dose. The absorbed dose is obtained by measuring every particle in either of the detectors. Additionally, particles traversing both diodes are detected as coincidences. From these measurements linear energy transfer (LET) spectra will be generated from which the quality factor of the field will be determined. Quality factor times absorbed dose in the detector gives the dose equivalent - a central quantity in radiation protection. Calibrations of the detector system have been and will further be performed with various radioactive sources, and with heavy ions at the Heavy Ion Medical Accelerator (HIMAC) facility at NIRS in Chiba, Japan.

  19. Smart Radiological Dosimeter

    SciTech Connect

    Kosslow, William J.; Bandzuch, Gregory S.

    2004-07-20

    A radiation dosimeter providing an indication of the dose of radiation to which the radiation sensor has been exposed. The dosimeter contains features enabling the monitoring and evaluating of radiological risks so that a user can concentrate on the task at hand. The dosimeter provides an audible alarm indication that a predetermined time period has elapsed, an audible alarm indication reminding the user to check the dosimeter indication periodically, an audible alarm indicating that a predetermined accumulated dose has been prematurely reached, and an audible alarm indication prior or to reaching the 3/4 scale point.

  20. Sunscreen use related to UV exposure, age, sex, and occupation based on personal dosimeter readings and sun-exposure behavior diaries.

    PubMed

    Thieden, Elisabeth; Philipsen, Peter A; Sandby-Møller, Jane; Wulf, Hans Christian

    2005-08-01

    To examine during what behaviors people apply sunscreen and to assess the relationship to UV exposure monitored by personal dosimetry and diaries. Open prospective observational study. University hospital. A convenience sample of 340 Danish volunteers: children, adolescents, indoor workers, sun worshippers, golfers, and gardeners (age range, 4-68 years). Intervention Subjects recorded sunscreen use and sun-exposure behavior in diaries and carried personal, electronic UV dosimeters, measuring time-stamped UV doses continuously, during a median of 119 days covering 346 sun-years (1 sun-year equals 1 subject participating during 1 summer season). Associations between sunscreen use and age, sex, skin type, occupation, sunburn, UV exposure doses, and behavior; and adequate application density and sun protection factor required to prevent sunburn. There were great variations in sunscreen use, which was highly correlated with risk behavior (sunbathing or exposing the upper body) (r = 0.39; P<.001). Sunscreens were used on a median of 5 days per sun-year (range, 1 day for gardeners to 16 days for sun worshippers). Ten percent of females and 41% of males never used sunscreens. Females used sunscreens more but also had more unprotected risk behavior than males (8 days vs 4 days; P<.001). Sunscreen use was not correlated with age, and children had as much unprotected risk behavior as adults. Sunscreens were used on 86% of the days with risk behavior in southern Europe vs 20% in northern Europe (P<.001). The UV doses were significantly higher on days with sunscreen (P< or = .03) and on sunburn days (P<.001). The median sun protection factor was 10.5. The sun-protecting effect corresponded to an application density of 0.5 mg/cm2. Days with sunscreen correlated not with days without risk behavior, but with days "sunbathing with the intention to tan," indicating that sunscreens were used as tanning aids to avoid sunburn.

  1. Wrist-watch dosimeter

    DOEpatents

    Wolf, M.A.; Waechter, D.A.; Umbarger, C.J.

    1982-04-16

    The disclosure is directed to a wristwatch dosimeter utilizing a CdTe detector, a microprocessor and an audio and/or visual alarm. The dosimeter is entirely housable within a conventional digital watch case having an additional aperture enabling the detector to receive radiation.

  2. The Mobile Dosimetric Telescope - A Small Size Active Personal Dosimeter for Application at High Altitudes and Onboard the International Space Station

    NASA Astrophysics Data System (ADS)

    Ritter, B.; Marsalek, K.; Berger, T.; Burmeister, S.; Reitz, G.; Heber, B.

    2012-12-01

    The radiation environment at cruising altitudes, as well as in Low Earth Orbit - like on the International Space Station - differs significantly from the natural radiation environment on Earth. Especially in Low Earth Orbit it poses one of the main health risks for long duration human missions. Therefore, it is essential to monitor the properties of the radiation field in such environments. The Mobile Dosimetric Telescope MDT, is a small size battery driven personal dosimeter based on silicon detector technology that has been developed to observe absorbed dose and dose rate in real time. Two silicon diodes are arranged in a telescope configuration, which allows the measurement of the ionizing constituents of the radiation field and partially the neutral contribution to the dose. The absorbed dose is obtained by considering every particle in either of the detectors. Particles traversing both diodes are detected as coincidence events that enable to derive linear energy transfer (LET) spectra. From these the quality factor of the field is determined, which is necessary for the estimation of the dose equivalent. The detection range of the device covers energy depositions from minimal ionizing particles up to relativistic heavy ions. Calibrations of the detector system have been performed with various radioactive sources and with heavy ions at the Heavy Ion Medical Accelerator (HIMAC) facility at the National Institute for Radiological Sciences (NIRS) in Chiba, Japan. Additionally, the MDT has been successfully tested onboard aircraft. The results of these measurements are in good agreement with those from other radiation detectors. The presentation will focus on data taken during long haul flights in the northern hemisphere.

  3. Printable UV personal dosimeter: sensitivity as a function of DoD parameters and number of layers of a functional photonic ink

    NASA Astrophysics Data System (ADS)

    Sousa, Felipe L. N.; Mojica-Sánchez, Lizeth C.; Gavazza, Sávia; Florencio, Lourdinha; Vaz, Elaine C. R.; Santa-Cruz, Petrus A.

    2016-04-01

    This work presents ‘intelligent papers’ obtained by functional inks printed on cellulose-sheets by DoD inkjet technology and their performance as a photonic device for UV-radiation dosimetry. The dosimeter operation is based on the photodegradation of the active part of a photonic ink, btfa (4,4,4-trifluoro-1-phenyl-1,3-butanedione) ligands in Eu(III) complex, as a function of the UV dose (Jcm-2), and the one-way device is read by the luminescence quenching of (5D0 → 7F2) Eu3+ transition after UV exposure of the printed paper. The printed dosimeter presented an exponential behavior, measured here up to 10 Jcm-2 for UV-A, UV-B and UV-C, and it was shown that the number of jetted layers could fit the dosimeter sensitivity.

  4. DNA UVB dosimeters.

    PubMed

    Regan, J D; Yoshida, H

    1995-11-01

    DNA can be used to establish and monitor solar UVB dose. Since the principal molecular site of UVB damage in living organisms is DNA, it is logical to quantitate biologically effective solar UVB in DNA dosimeters. In addition to their particular sensitivity to UVB, DNA dosimeters have the advantage of a 2 pi geometry for collecting diffuse UVB radiation from all vectors, low cost, small size and portability, and no moving parts. Both molecular (cyclobutane pyrimidine dimers) and biological (bacteriophage plaques) dosimeters can be quantitated as endpoints to yield the total dose. DNA dosimeters integrate the absorbed energy of all UVB wavelengths (290-320 nm), are highly sensitive to the differential biological effectiveness of these wavelengths, and also integrate over time in hours, days or weeks of exposure. Our experiments have focused on the demonstration of DNA solar dosimeters in the ocean at various depths, the application of the dosimeters to the terrestrial monitoring of solar UVB under various conditions, and the development of a mini-dosimeter which uses nanograms of DNA and is assayed by polymerase chain reaction.

  5. Temporal dosimeter and method

    DOEpatents

    Warner, Benjamin P.; Lopez, Thomas A.

    2003-09-30

    The invention includes a temporal dosimeter. One dosimeter embodiment includes a housing that is opaque to visible light but transparent to ionizing radiation. The dosimeter also includes a sensor for recording dosages of ionizing radiation, a drive mechanism, a power source, and rotatable shields that work together to produce a compound aperture to unveil different portions of the sensor at different times to ionizing radiation. Another dosimeter embodiment includes a housing, a sensor, a shield with an aperture portion, and a linear actuator drive mechanism coupled to the sensor for moving the sensor past the aperture portion. The sensor turns as it moves past the aperture, tracing a timeline record of exposure to ionizing radiation along a helical path on the sensor.

  6. ULTRASONIC NEUTRON DOSIMETER

    DOEpatents

    Truell, R.; de Klerk, J.; Levy, P.W.

    1960-02-23

    A neutron dosimeter is described which utilizes ultrasonic waves in the megacycle region for determination of the extent of neutron damage in a borosilicate glass through ultrasonic wave velocity and attenuation measurements before and after damage.

  7. Magnetic field dosimeter development

    SciTech Connect

    Lemon, D.K.; Skorpik, J.R.; Eick, J.L.

    1980-09-01

    In recent years there has been increased concern over potential health hazards related to exposure of personnel to magnetic fields. If exposure standards are to be established, then a means for measuring magnetic field dose must be available. To meet this need, the Department of Energy has funded development of prototype dosimeters at the Battelle Pacific Northwest Laboratory. This manual reviews the principle of operation of the dosimeter and also contains step-by-step instructions for its operation.

  8. Measurement of individual doses of radiation by personal dosimeter is important for the return of residents from evacuation order areas after nuclear disaster.

    PubMed

    Orita, Makiko; Hayashida, Naomi; Taira, Yasuyuki; Fukushima, Yoshiko; Ide, Juichi; Endo, Yuuko; Kudo, Takashi; Yamashita, Shunichi; Takamura, Noboru

    2015-01-01

    To confirm the availability of individual dose evaluation for the return of residents after the accident at the Fukushima Dai-ichi Nuclear Power Plant (FNPP), we evaluated individual doses of radiation as measured by personal dosimeters in residents who temporarily stayed in Evacuation Order Areas in Kawauchi village, which is partially located within a 20 km radius of the FNPP. We also compared individual doses with the external radiation doses estimated from the ambient dose rates and with doses estimated from the concentrations of radionuclides in the soil around each individual's house. Individual doses were significantly correlated with the ambient doses in front of the entrances to the houses (r = 0.90, p<0.01), in the backyards (r = 0.41, p<0.01) and in the nearby fields (r = 0.80, p<0.01). The maximum cumulative ambient doses in the backyards and fields around the houses were 6.38 and 9.27 mSv/y, respectively. The maximum cumulative individual dose was 3.28 mSv/y, and the median and minimum doses were 1.35 and 0.71 mSv/y. The estimated external effective doses from concentrations of artificial radionuclides in soil samples ranged from 0.03 to 23.42 mSv/y. The individual doses were moderately correlated with external effective doses in the backyards (r = 0.38, p<0.01) and in the fields (r = 0.36, p<0.01); however, the individual doses were not significantly correlated with the external effective doses in front of the entrances (r = 0.01, p = 0.92). Our study confirmed that individual doses are low levels even in the evacuation order area in Kawauchi village, and external effective dose levels are certainly decreasing due to the decay of artificial radionuclides and the decontamination of contaminated soil. Long-term follow-up of individual doses as well as internal-exposure doses, environmental monitoring and reconstruction of infrastructure are needed so that residents may return to their hometowns after a nuclear disaster.

  9. Measurement of Individual Doses of Radiation by Personal Dosimeter Is Important for the Return of Residents from Evacuation Order Areas after Nuclear Disaster

    PubMed Central

    Orita, Makiko; Hayashida, Naomi; Taira, Yasuyuki; Fukushima, Yoshiko; Ide, Juichi; Endo, Yuuko; Kudo, Takashi; Yamashita, Shunichi; Takamura, Noboru

    2015-01-01

    To confirm the availability of individual dose evaluation for the return of residents after the accident at the Fukushima Dai-ichi Nuclear Power Plant (FNPP), we evaluated individual doses of radiation as measured by personal dosimeters in residents who temporarily stayed in Evacuation Order Areas in Kawauchi village, which is partially located within a 20 km radius of the FNPP. We also compared individual doses with the external radiation doses estimated from the ambient dose rates and with doses estimated from the concentrations of radionuclides in the soil around each individual’s house. Individual doses were significantly correlated with the ambient doses in front of the entrances to the houses (r = 0.90, p<0.01), in the backyards (r = 0.41, p<0.01) and in the nearby fields (r = 0.80, p<0.01). The maximum cumulative ambient doses in the backyards and fields around the houses were 6.38 and 9.27 mSv/y, respectively. The maximum cumulative individual dose was 3.28 mSv/y, and the median and minimum doses were 1.35 and 0.71 mSv/y. The estimated external effective doses from concentrations of artificial radionuclides in soil samples ranged from 0.03 to 23.42 mSv/y. The individual doses were moderately correlated with external effective doses in the backyards (r = 0.38, p<0.01) and in the fields (r = 0.36, p<0.01); however, the individual doses were not significantly correlated with the external effective doses in front of the entrances (r = 0.01, p = 0.92). Our study confirmed that individual doses are low levels even in the evacuation order area in Kawauchi village, and external effective dose levels are certainly decreasing due to the decay of artificial radionuclides and the decontamination of contaminated soil. Long-term follow-up of individual doses as well as internal-exposure doses, environmental monitoring and reconstruction of infrastructure are needed so that residents may return to their hometowns after a nuclear disaster. PMID:25806523

  10. Length of stain dosimeter

    NASA Technical Reports Server (NTRS)

    Lueck, Dale E. (Inventor)

    1994-01-01

    Payload customers for the Space Shuttle have recently expressed concerns about the possibility of their payloads at an adjacent pad being contaminated by plume effluents from a shuttle at an active pad as they await launch on an inactive pad. As part of a study to satisfy such concerns a ring of inexpensive dosimeters was deployed around the active pad at the inter-pad distance. However, following a launch, dosimeters cannot be read for several hours after the exposure. As a consequence factors such as different substrates, solvent systems, and possible volatilization of HCl from the badges were studied. This observation led to the length of stain (LOS) dosimeters of this invention. Commercial passive LOS dosimeters are sensitive only to the extent of being capable of sensing 2 ppm to 20 ppm if the exposure is 8 hours. To map and quantitate the HCl generated by Shuttle launches, and in the atmosphere within a radius of 1.5 miles from the active pad, a sensitivity of 2 ppm HCl in the atmospheric gases on an exposure of 5 minutes is required. A passive length of stain dosimeter has been developed having a sensitivity rendering it capable of detecting a gas in a concentration as low as 2 ppm on an exposure of five minutes.

  11. Fact-finding Survey in Response to the Manipulation of Personal Alarm Dosimeter Collection Efficiency: Lessons Learned About Post-Emergency Radiation Protection from the TEPCO Fukushima Daiichi APP Accident.

    PubMed

    Yasui, Shojiro

    2015-01-01

    During emergency work at TEPCO Fukushima Daiichi Atomic Power Plant on December 1, 2011 a subcontractor demanded that its contracted workers cover their personal alarm dosimeters (PAD) with 3-cm-thick lead plates to lower dosimeter readings. As a response, the Ministry of Health, Labour and Welfare (MHLW) conducted a fact-finding survey to identify similar cases and devise measures to prevent a recurrence of this incident. To screen the suspected cases, the MHLW extracted: a) cases in which a PAD reading was at least 15% higher than the reading obtained from a radio-photolumine-scence dosimeter (RPD), where the dose was greater than 5 mSv in a month (1813 data points), and b) dose data in which PAD readings were less than 50% of the expected dose, where exposure dose may exceed 1 mSv in a day (56 workers, 17,148 data points). From these screenings, the MHLW identified 50 instances from TEPCO and nine primary contractors, including four general contractors, two plant manufacturers, and three plant maintenance companies as the subjects of the due diligence study of exposure data, including interviews. The results of the survey provide lessons that can also be applied to transition from emergency radiation protection to normal operation, as the application of emergency dose limits had ceased on December 16, 2011, in the affected plant. Based on the results of the survey, the MHLW provided administrative guidance documents to TEPCO and 37 primary contractors. The major points of these documents include: a) identification of recorded dose values by comparison of PAD readings to RPD readings, b) storage and management of RPDs and control badges, c) circulation management of PADs and access control to the affected plant, d) estimation of planned doses and setting of alarm values of PADs, e) actions to be taken by contractors if worker dose limits are reached, and f) physical measures to prevent recurrence of the incident.

  12. Limitations of using dosimeters in impulse noise environments.

    PubMed

    Kardous, Chucri A; Willson, Robert D

    2004-07-01

    The National Institute for Occupational Safety and Health (NIOSH) investigated the capabilities of noise dosimeters to measure personal exposure to impulse noise. The two leading types of commercially available dosimeters were evaluated in terms of their ability to measure and integrate impulses generated from gunfire during live-fire exercises at a law enforcement indoor firing range. Sound measurements were conducted throughout the firing range using dosimeters, sound level meters, and a measurement configuration that consisted of a quarter-inch microphone and a digital audiotape recorder to capture the impulse waveforms. Personal dosimetry was conducted on eight shooters, an observer, and the range master. Peak levels from gunfire reached 163 decibels (dB), exceeding the nominal input limit of the dosimeters. The dosimeters "clipped" the impulses by acting as if the gunfire had a maximum level of 146 dB. In other cases, however, peak levels (e.g., 108 dB) were below the dosimeter input limits, but the dosimeters still showed a peak level of 146 dB. Although NIOSH recommends that sound levels from 80 to 140 dB (A-weighted) be integrated in the calculation of dose and the time-weighted average, our present data suggest this criterion may be inadequate. These results showed that some instruments are incapable of providing accurate measures of impulse sounds because of their electroacoustic limitations.

  13. Dosimeter for monitoring vapors and aerosols of organic compounds

    DOEpatents

    Vo-Dinh, T.

    1987-07-14

    A dosimeter is provided for collecting and detecting vapors and aerosols of organic compounds. The dosimeter comprises a lightweight, passive device that can be conveniently worn by a person as a badge or placed at a stationary location. The dosimeter includes a sample collector comprising a porous web treated with a chemical for inducing molecular displacement and enhancing phosphorescence. Compounds are collected onto the web by molecular diffusion. The web also serves as the sample medium for detecting the compounds by a room temperature phosphorescence technique. 7 figs.

  14. Dosimeter for monitoring vapors and aerosols of organic compounds

    DOEpatents

    Vo-Dinh, Tuan

    1987-01-01

    A dosimeter is provided for collecting and detecting vapors and aerosols of organic compounds. The dosimeter comprises a lightweight, passive device that can be conveniently worn by a person as a badge or placed at a stationary location. The dosimeter includes a sample collector comprising a porous web treated with a chemical for inducing molecular displacement and enhancing phosphorescence. Compounds are collected onto the web by molecular diffusion. The web also serves as the sample medium for detecting the compounds by a room temperature phosphorescence technique.

  15. Dose equivalent neutron dosimeter

    DOEpatents

    Griffith, Richard V.; Hankins, Dale E.; Tomasino, Luigi; Gomaa, Mohamed A. M.

    1983-01-01

    A neutron dosimeter is disclosed which provides a single measurements indicating the amount of potential biological damage resulting from the neutron exposure of the wearer, for a wide range of neutron energies. The dosimeter includes a detecting sheet of track etch detecting material such as a carbonate plastic, for detecting higher energy neutrons, and a radiator layer containing conversion material such as .sup.6 Li and .sup.10 B lying adjacent to the detecting sheet for converting moderate energy neutrons to alpha particles that produce tracks in the adjacent detecting sheet. The density of conversion material in the radiator layer is of an amount which is chosen so that the density of tracks produced in the detecting sheet is proportional to the biological damage done by neutrons, regardless of whether the tracks are produced as the result of moderate energy neutrons striking the radiator layer or as the result of higher energy neutrons striking the sheet of track etch material.

  16. Dosimeter Badge Detects Hydrazines

    NASA Technical Reports Server (NTRS)

    Young, Rebecca C.; Travis, Joshua C.; Moore, Gerald; Rose-Pehrsson, Susan; Carver, Patricia; Brenner, Karen

    1993-01-01

    Disposable dosimeter badge indicates approximate cumulative exposure to hydrazine or monomethyl hydrazine in air. Indication is change in colors of both paper tapes; one coated with para-N, N-dimethylaminobenzaldehyde. Colors of exposed tapes compared with colors on two preprinted color wheels to obtain estimate of exposure. Badges help minimize risks associated with exposure of personnel to hydrazine or monomethyl hydrazine, or suspected carcinogens. Also used as stationary monitors by taping them on walls or equipment at strategic locations.

  17. Dosimeter Design Program

    DTIC Science & Technology

    2015-01-05

    Configure pins for start - up : SysTimerSetupFast(); // Start the system tick timer com_initialize...be utilized. Non-hardened parts can often be an order of magnitude less in cost .  Design a dosimeter that is radiation hardened. We will use...prototype developed under this activity since the cost for the radiation hardened parts would be prohibitive. Various chips that are radiation

  18. Photoacoustical radiation dosimeter

    SciTech Connect

    Mascarenhas, S.; Vargas, H.; Cesar, C.L.

    1984-01-01

    A new type of radiation dosimeter using the photoacoustical effect is described. The photoacoustical radiation dosimeter (PARD) is capable of directly measuring the energy absorbed in the detecting element. For a completely absorbing element, the energy fluence rate in the radiation beam is measured. It is thus a calorimetric dosimeter. Since the energy sensor can be calibrated with another form of energy, it has the potential for being an absolute radiation dosemeter. Measurements were made using 50 to 100 kVp x rays with exposure rates at the detector of 2.6 x 10/sup -6/ C/kg/s (10 mR/s) to 5 x 10/sup -5/ C/kg/s (200 mR/s). The minimum measurable exposure rate at 90 kVp is 5 x 10/sup -7/ C/kg/s (2 mR/s). For a given x-ray spectrum, the PARD has a linear response with radiation intensity and an inverse response with chopping frequency. With appropriate design parameters, we believe the PARD may be used to measure any photon energy or any type of radiation particle.

  19. Hanford personnel dosimeter supporting studies FY-1981

    SciTech Connect

    Not Available

    1982-08-01

    This report examined specific functional components of the routine external personnel dosimeter program at Hanford. Components studied included: dosimeter readout; dosimeter calibration; dosimeter field response; dose calibration algorithm; dosimeter design; and TLD chip acceptance procedures. Additional information is also presented regarding the dosimeter response to light- and medium-filtered x-rays, high energy photons and neutrons. This study was conducted to clarify certain data obtained during the FY-1980 studies.

  20. PERSONNEL NEUTRON DOSIMETER

    DOEpatents

    Fitzgerald, J.J.; Detwiler, C.G. Jr.

    1960-05-24

    A description is given of a personnel neutron dosimeter capable of indicating the complete spectrum of the neutron dose received as well as the dose for each neutron energy range therein. The device consists of three sets of indium foils supported in an aluminum case. The first set consists of three foils of indium, the second set consists of a similar set of indium foils sandwiched between layers of cadmium, whereas the third set is similar to the second set but is sandwiched between layers of polyethylene. By analysis of all the foils the neutron spectrum and the total dose from neutrons of all energy levels can be ascertained.

  1. Ionization chamber dosimeter

    DOEpatents

    Renner, Tim R.; Nyman, Mark A.; Stradtner, Ronald

    1991-01-01

    A method for fabricating an ion chamber dosimeter collecting array of the type utilizing plural discrete elements formed on a uniform collecting surface which includes forming a thin insulating layer over an aperture in a frame having surfaces, forming a predetermined pattern of through holes in the layer, plating both surfaces of the layer and simultaneously tilting and rotating the frame for uniform plate-through of the holes between surfaces. Aligned masking and patterned etching of the surfaces provides interconnects between the through holes and copper leads provided to external circuitry.

  2. Miniature personal uv solar dosimeter: small light-powered meter measures accumulated radiation in the ultraviolet or other selected regions. NTIS tech note

    SciTech Connect

    Not Available

    1981-11-01

    This citation summarizes a one-page announcement of technology available for utilization. A miniature integrating light meter originally developed for use in space has many other possible applications. Small enough to be worn unobtrusively, it can measure accurately the radiation dose accumulated for a few minutes or over a period of weeks. It can measure total light or selected wave bands, such as UV or IR. The primary practical advantages of the dosimeter are its potentially low cost, small size, accuracy, and adaptability to specific wave-band measurements. Medical applications suggested include as a research tool for studies of skin cancer, vitamin D production, and jaundice and for possible use in conjuction with the treatments involving Sunlight exposure. It could be further used to measure integrated Sunlight for solar-energy design, for agriculture and meteorology, and to study and monitor the stability of materials and environmental and occupatinal lighting. The meter uses a planar-diffused silicon photovoltaic detector as a sensor and a commercially available electrochemical coulometer to measure light accumulation....FOR ADDITIONAL INFORMATION: Contact: Inquiries concerning nonexclusive or exclusive license for its commercial development should be addressed to the Patent Counsel, Langley Research Center, Hampton, VA. Refer To LAR-12469.

  3. Pistol-shaped dosimeter charger

    DOEpatents

    Maples, R.A.

    A pistol-shaped charger assembly clamps a cylindrical radiation dosimeter against one edge thereof. A triggerlike lever on the handgrip of the assembly is manually pivoted to actuate a piezoelectric current generator held in the handgrip and thereby charge the dosimeter.

  4. Pistol-shaped dosimeter charger

    DOEpatents

    Maples, Robert A.

    1985-01-01

    A pistol-shaped charger assembly clamps a cylindrical radiation dosimeter against one edge thereof. A triggerlike lever on the handgrip of the assembly is manually pivoted to actuate a piezoelectric current generator held in the handgrip and thereby charge the dosimeter.

  5. A new radiochromic dosimeter film

    NASA Astrophysics Data System (ADS)

    Sidney, L. N.; Lynch, D. C.; Willet, P. S.

    By employing acid-sensitive leuco dyes in a chlorine-containing polymer matrix, a new radiochromic dosimeter film has been developed for gamma, electron beam, and ultraviolet radiation. These dosimeter films undergo a color change from colorless to royal blue, red fuchsia, or black, depending on dye selection, and have been characterized using a visible spectrophotometer over an absorbed dose range of 1 to 100 kGy. The primary features of the film are improved color stability before and after irradiation, whether stored in the dark or under artificial lights, and improved moisture resistance. The effects of absorbed dose, dose rate, and storage conditions on dosimeter performance are discussed. The dosimeter material may be produced as a free film or coated onto a transparent substrate and optionally backed with adhesive. Potential applications for these materials include gamma sterilization indicator films for food and medical products, electron beam dosimeters, and in-line radiation monitors for electron beam and ultraviolet processing.

  6. Applicability of the polysulphone horizontal calibration to differently inclined dosimeters.

    PubMed

    Casale, Giuseppe R; Siani, Anna Maria; Diémoz, Henri; Kimlin, Michael G; Colosimo, Alfredo

    2012-01-01

    Polysulphone (PS) dosimetry has been a widely used technique for more than 30 years to quantify the erythemally effective UV dose received by anatomic sites (personal exposure). The calibration of PS dosimeters is an important issue as their spectral response is different from the erythemal action spectrum. It is performed exposing a set of PS dosimeters on a horizontal plane and measuring the UV doses received by dosimeters using calibrated spectroradiometers or radiometers. In this study, data collected during PS field campaigns (from 2004 to 2006), using horizontal and differently inclined dosimeters, were analyzed to provide some considerations on the transfer of the horizontal calibration to differently inclined dosimeters, as anatomic sites usually are. The role of sky conditions, of the angle of incidence between the sun and the normal to the slope, and of the type of surrounding surface on the calibration were investigated. It was concluded that PS horizontal calibrations apply to differently inclined dosimeters for incidence angles up to approximately 70° and for surfaces excluding ones with high albedo. Caution should be used in the application of horizontal calibrations for cases of high-incidence angle and/or high albedo surfaces.

  7. Personnel electronic neutron dosimeter

    DOEpatents

    Falk, R.B.; Tyree, W.H.

    1982-03-03

    A personnel electronic dosimeter includes a neutron-proton and neutron-alpha converter for providing an electrical signal having a magnitude proportional to the energy of a detected proton or alpha particle produced from the converter, a pulse generator circuit for generating a pulse having a duration controlled by the weighed effect of the amplitude of the electrical signal, an oscillator enabled by the pulse for generating a train of clock pulses for a time dependent upon the pulse length, a counter for counting the clock pulses, and an indicator for providing a direct reading and aural alarm when the count indicates that the wearer has been exposed to a selected level of neutron dose equivalent.

  8. Personnel electronic neutron dosimeter

    DOEpatents

    Falk, Roger B.; Tyree, William H.

    1984-12-18

    A personnel electronic dosimeter includes a neutron-proton and neutron-alpha converter for providing an electrical signal having a magnitude proportional to the energy of a detected proton or alpha particle produced from the converter, a pulse generator circuit for generating a pulse having a duration controlled by the weighed effect of the amplitude of the electrical signal, an oscillator enabled by the pulse for generating a train of clock pulses for a time dependent upon the pulse length, a counter for counting the clock pulses, and an indicator for providing a direct reading and aural alarm when the count indicates that the wearer has been exposed to a selected level of neutron dose equivalent.

  9. Miniature spectrally selective dosimeter

    NASA Technical Reports Server (NTRS)

    Adams, R. R.; Macconochie, I. O.; Poole, B. D., Jr. (Inventor)

    1980-01-01

    A miniature spectrally selective dosimeter capable of measuring selected bandwidths of radiation exposure on small mobile areas is described. This is achieved by the combination of photovoltaic detectors, electrochemical integrators (E-cells) and filters in a small compact case which can be easily attached in close proximity to and substantially parallel to the surface being measured. In one embodiment two photovoltaic detectors, two E-cells, and three filters are packaged in a small case with attaching means consisting of a safety pin. In another embodiment, two detectors, one E-cell, three filters are packaged in a small case with attaching means consisting of a clip to clip over a side piece of an eye glass frame.

  10. Miniature spectrally selective dosimeter

    NASA Astrophysics Data System (ADS)

    Adams, R. R.; MacConochie, I. O.; Poole, B. D., Jr.

    1980-10-01

    A miniature spectrally selective dosimeter capable of measuring selected bandwidths of radiation exposure on small mobile areas is described. This is achieved by the combination of photovoltaic detectors, electrochemical integrators (E-cells) and filters in a small compact case which can be easily attached in close proximity to and substantially parallel to the surface being measured. In one embodiment two photovoltaic detectors, two E-cells, and three filters are packaged in a small case with attaching means consisting of a safety pin. In another embodiment, two detectors, one E-cell, three filters are packaged in a small case with attaching means consisting of a clip to clip over a side piece of an eye glass frame.

  11. Silver nitrate based gel dosimeter

    NASA Astrophysics Data System (ADS)

    Titus, D.; Samuel, E. J. J.; Srinivasan, K.; Roopan, S. M.; Madhu, C. S.

    2017-05-01

    A new radiochromic gel dosimeter based on silver nitrate and a normoxic gel dosimeter was investigated using UV-Visible spectrophotometry in the clinical dose range. Gamma radiation induced the synthesis of silver nanoparticles in the gel and is confirmed from the UV-Visible spectrum which shows an absorbance peak at around 450 nm. The dose response function of the dosimeter is found to be linear upto12Gy. In addition, the gel samples were found to be stable which were kept under refrigeration.

  12. Brachytherapy dosimeter with silicon photomultipliers

    NASA Astrophysics Data System (ADS)

    Moutinho, L. M.; Castro, I. F. C.; Peralta, L.; Abreu, M. C.; Veloso, J. F. C. A.

    2015-07-01

    In-vivo and in-situ measurement of the radiation dose administered during brachytherapy faces several technical challenges, requiring a very compact, tissue-equivalent, linear and highly sensitive dosimeter, particularly in low-dose rate brachytherapy procedures, which use radioactive seeds with low energy and low dose deposition rate. In this work we present a scintillating optical fiber dosimeter composed of a flexible sensitive probe and a dedicated electronic readout system based on silicon photomultiplier photodetection, capable of operating both in pulse and current modes. The performance of the scintillating fiber optic dosimeter was evaluated in low energy regimes, using an X-ray tube operating at voltages of 40-50 kV and currents below 1 mA, to assess minimum dose response of the scintillating fiber. The dosimeter shows a linear response with dose and is capable of detecting mGy dose variations like an ionization chamber. Besides fulfilling all the requirements for a dosimeter in brachytherapy, the high sensitivity of this device makes it a suitable candidate for application in low-dose rate brachytherapy. According to Peralta and Rego [1], the BCF-10 and BCF-60 scintillating optical fibers used in dosimetry exhibit high variations in their sensitivity for photon beams in the 25-100 kVp energy range. Energy linearity for energies below 50 keV needs to be further investigated, using monochromatic X-ray photons.

  13. Proton dosimeter design for distributed body organs.

    NASA Technical Reports Server (NTRS)

    Khandelwal, G. S.; Wilson, J. W.

    1973-01-01

    The design of a real-time rem-rad dosimeter with sufficient generality for inclusion of dose distribution factors for space applications is discussed. This generalized dosimetric system is only slightly more complex than dosimeters in current use.

  14. Dose-equivalent neutron dosimeter

    DOEpatents

    Griffith, R.V.; Hankins, D.E.; Tomasino, L.; Gomaa, M.A.M.

    1981-01-07

    A neutron dosimeter is disclosed which provides a single measurement indicating the amount of potential biological damage resulting from the neutron exposure of the wearer, for a wide range of neutron energies. The dosimeter includes a detecting sheet of track etch detecting material such as a carbonate plastic, for detecting higher energy neutrons, and a radiator layer contaning conversion material such as /sup 6/Li and /sup 10/B lying adjacent to the detecting sheet for converting moderate energy neutrons to alpha particles that produce tracks in the adjacent detecting sheet.

  15. Spectrophotometry of PRESAGETM polyurethane dosimeters

    NASA Astrophysics Data System (ADS)

    Krstajic, N.; Wai, P.; Adamovics, J.; Doran, S.

    2004-01-01

    Preliminary optical density results on irradiated PRESAGE dosimeter are outlined in this article. PRESAGE is a solid dosimeter, based on a clear polyurethane combined with the leuco-dye leuco-malachite green. The purpose of these measurements was a) to obtain spectra for optimizing the wavelength of a new light source for the equipment and b) to obtain a dose-response relation. 10 PRESAGE cuvettes were given uniform doses from 0.1 to 40 Gy and later read out by spectrophotometer. The instrument used was CAMSPEC M350 Double Beam Spectrophotometer.

  16. Characteristics of the DINA track dosimeter for monitoring chronic neutron exposure

    SciTech Connect

    Kraitor, S.N.; Kuz'mina, T.D.; Savinskii, A.K.

    1987-09-01

    The DINA personal dosimeter included in the GNEIS beta-, gamma-, and neutron-radiation safety kit uses fission-fragment track detectors and a target containing /sup 237/Np with a /sup 10/B filter. The purpose of this paper is to derive quantitative data on the characteristics of the DINA dosimeter in the measurement of the equivalent kerma during chronic personnel exposure in neutron fields, and to evaluate whether in that situation the dosimeter can be effectively used when only the track dose value varies.

  17. Personal crew dosimeters for LEO and beyond

    NASA Astrophysics Data System (ADS)

    Conroy, Thomas; Conroy, Thomas; Watson Huber, Aubrey; Braby, Leslie

    Tissue Equivalent Proportional Counter (TEPC) Instrument Next Generation Device for Individual Dosimetric Monitoring Until recently, TEPC devices used by NASA have been stationary; they were too large and too heavy to be truly portable. With the help of recent advances in the electronics industry, a new generation of TEPC device is being designed and tested for mixed field radiation measurements. These will be smaller, lighter, and with lower power consumption than existing devices. The smaller units can be worn by individuals and thereby provide dosimetric monitoring of an individual's immediate environment, increasing the accuracy of their measured exposure levels. A portable TEPC could be used in a variety of space vehicles (Space Shuttle, ISS, CEV, etc.), as well as on EVAs and excursions on the Moon and Mars. To reduce the detector volume and weight, a new TEPC detector configuration will be used. The detector will consist of eighteen half-inch spherical detectors arranged in a 2-D array. The detector size will be approximately 3x4x1 inches. Sixteen detectors will be connected to obtain a chamber equivalent to a spherical 2-inch-diameter detector for measurements in low fluence environments. The remaining two half-inch detectors will be standalone; one for measurement in high fluence environments and the other for continuous calibration. The final unit is projected to be 4x6x1 inches, weigh less than 8 oz, and consume less than 100 milli-watts of power. Operating time is estimated to be roughly 24 hours on two AA batteries. The unit, similar to the Space Shuttle TEPC, will acquire full spectrums each minute and store them on an SD card. There will be five spectrums stored: a high and low LET spectrum for both detectors as well as one spectrum for the calibration. The high LET spectrum is from 0 to 1500 keV/um on 1.5 keV per channel, and the low LET spectrum is from 0 to 22.0 keV/um on 0.1 keV per channel.

  18. RADIATION DOSIMETER AND DOSIMETRIC METHODS

    DOEpatents

    Taplin, G.V.

    1958-10-28

    The determination of ionizing radiation by means of single fluid phase chemical dosimeters of the colorimetric type is presented. A single fluid composition is used consisting of a chlorinated hydrocarbon, an acidimetric dye, a normalizer and water. Suitable chlorinated hydrocarbons are carbon tetrachloride, chloroform, trichloroethylene, trichlorethane, ethylene dichioride and tetracbloroethylene. Suitable acidimetric indicator dyes are phenol red, bromcresol purple, and creosol red. Suitable normallzers are resorcinol, geraniol, meta cresol, alpha -tocopberol, and alpha -naphthol.

  19. Response of TLD-albedo and nuclear track dosimeters exposed to plutonium sources

    SciTech Connect

    Brackenbush, L.W.; Baumgartner, W.V.; Fix, J.J.

    1991-12-01

    Neutron dosimetry has been extensively studied at Hanford since the mid-1940s. At the present time, Hanford contractors use thermoluminescent dosimeter (TLD)-albedo dosimeters to record the neutron dose equivalent received by workers. The energy dependence of the TLD-albedo dosimeter has been recognized and documented since introduced at Hanford in 1964 and numerous studies have helped assure the accuracy of dosimeters. With the recent change in Hanford`s mission, there has been a significant decrease in the handling of plutonium tetrafluoride, and an increase in the handling of plutonium metal and plutonium oxide sources. This study was initiated to document the performance of the current Hanford TLD-albedo dosimeter under the low scatter conditions of the calibration laboratory and under the high scatter conditions in the work place under carefully controlled conditions at the Plutonium Finishing Plant (PFP). The neutron fields at the PFP facility were measured using a variety of instruments, including a multisphere spectrometer, tissue equivalent proportional counters, and specially calibrated rem meters. Various algorithms were used to evaluate the TLD-albedo dosimeters, and the results are given in this report. Using current algorithms, the dose equivalents evaluated for bare sources and sources with less than 2.5 cm (1 in.) of acrylic plastic shielding in high scatter conditions typical of glove box operations are reasonably accurate. Recently developed CR-39 track etch dosimeters (TEDs) were also exposed in the calibration laboratory and at the PFP. The results indicate that the TED dosimeters are quite accurate for both bare and moderated neutron sources. Until personnel dosimeter is available that incorporates a direct measure of the neutron dose to a person, technical uncertainties in the accuracy of the recorded data will continue.

  20. Response of TLD-albedo and nuclear track dosimeters exposed to plutonium sources

    SciTech Connect

    Brackenbush, L.W.; Baumgartner, W.V.; Fix, J.J.

    1991-12-01

    Neutron dosimetry has been extensively studied at Hanford since the mid-1940s. At the present time, Hanford contractors use thermoluminescent dosimeter (TLD)-albedo dosimeters to record the neutron dose equivalent received by workers. The energy dependence of the TLD-albedo dosimeter has been recognized and documented since introduced at Hanford in 1964 and numerous studies have helped assure the accuracy of dosimeters. With the recent change in Hanford's mission, there has been a significant decrease in the handling of plutonium tetrafluoride, and an increase in the handling of plutonium metal and plutonium oxide sources. This study was initiated to document the performance of the current Hanford TLD-albedo dosimeter under the low scatter conditions of the calibration laboratory and under the high scatter conditions in the work place under carefully controlled conditions at the Plutonium Finishing Plant (PFP). The neutron fields at the PFP facility were measured using a variety of instruments, including a multisphere spectrometer, tissue equivalent proportional counters, and specially calibrated rem meters. Various algorithms were used to evaluate the TLD-albedo dosimeters, and the results are given in this report. Using current algorithms, the dose equivalents evaluated for bare sources and sources with less than 2.5 cm (1 in.) of acrylic plastic shielding in high scatter conditions typical of glove box operations are reasonably accurate. Recently developed CR-39 track etch dosimeters (TEDs) were also exposed in the calibration laboratory and at the PFP. The results indicate that the TED dosimeters are quite accurate for both bare and moderated neutron sources. Until personnel dosimeter is available that incorporates a direct measure of the neutron dose to a person, technical uncertainties in the accuracy of the recorded data will continue.

  1. Fast-neutron solid-state dosimeter

    DOEpatents

    Kecker, K.H.; Haywood, F.F.; Perdue, P.T.; Thorngate, J.H.

    1975-07-22

    This patent relates to an improved fast-neutron solid-state dosimeter that does not require separation of materials before it can be read out, that utilizes materials that do not melt or otherwise degrade at about 300$sup 0$C readout temperature, that provides a more efficient dosimeter, and that can be reused. The dosimeters are fabricated by intimately mixing a TL material, such as CaSO$sub 4$:Dy, with a powdered polyphenyl, such as p-sexiphenyl, and hot- pressing the mixture to form pellets, followed by out-gassing in a vacuum furnace at 150$sup 0$C prior to first use dosimeters. (auth)

  2. Portable neutron spectrometer and dosimeter

    DOEpatents

    Waechter, David A.; Erkkila, Bruce H.; Vasilik, Dennis G.

    1985-01-01

    The disclosure relates to a battery operated neutron spectrometer/dosimeter utilizing a microprocessor, a built-in tissue equivalent LET neutron detector, and a 128-channel pulse height analyzer with integral liquid crystal display. The apparatus calculates doses and dose rates from neutrons incident on the detector and displays a spectrum of rad or rem as a function of keV per micron of equivalent tissue and also calculates and displays accumulated dose in millirads and millirem as well as neutron dose rates in millirads per hour and millirem per hour.

  3. Portable neutron spectrometer and dosimeter

    DOEpatents

    Waechter, D.A.; Erkkila, B.H.; Vasilik, D.G.

    The disclosure relates to a battery operated neutron spectrometer/dosimeter utilizing a microprocessor, a built-in tissue equivalent LET neutron detector, and a 128-channel pulse height analyzer with integral liquid crystal display. The apparatus calculates doses and dose rates from neutrons incident on the detector and displays a spectrum of rad or rem as a function of keV per micron of equivalent tissue and also calculates and displays accumulated dose in millirads and millirem as well as neutron dose rates in millirads per hour and millirem per hour.

  4. BETA-GAMMA PERSONNEL DOSIMETER

    DOEpatents

    Davis, D.M.; Gupton, E.D.; Hart, J.C.; Hull, A.P.

    1961-01-17

    A personnel dosimeter is offered which is sensitive to both gamma and soft beta radiations from all directions within a hemisphere. The device is in the shape of a small pill box which is worn on a worker-s wrist. The top and sides of the device are provided with 50 per cent void areas to give 50 per cent response to the beta rays and complete response to the gamma rays. The device is so constructed as to have a response which will approximate the dose received by the basal layer of the human epidermis.

  5. An investigation into the sensitivity of various albedo neutron dosimeters aimed at correcting the readings

    NASA Astrophysics Data System (ADS)

    Alekseev, A. G.; Mokrov, Yu. V.; Morozova, S. V.

    2012-03-01

    The results of an experimental determination of the sensitivity of three types of individual neutron albedo dosimeters in neutron reference fields on the basis of radionuclide sources and at the top concrete shielding of the U-70 accelerator are presented. The results show that the ratios between the responses of the albedo dosimeters designed earlier at the Joint Institute for Nuclear Research (the albedo dosimeter (AD) and the multicomponent dosimeter (MD)) and the currently used DVGN-01 dosimeter are constant within 25% in a wide range of neutron energy. This fact makes it possible to use the results of measuring the AD and MD responses obtained earlier in neutron fields of nuclear-physical installations at the Joint Institute for Nuclear Research (JINR) for the correction of DVGN-01 dosimeter measurement results to apply it to personal radiation monitoring (PRM) at these installations. The correction factors for DVGN-01 measurement results are found and recommended to be used in PRM for most JINR installations.

  6. Characterization of a Tissue-Equivalent Dosimeter based on CMOS Solid-State Photomultipliers

    NASA Astrophysics Data System (ADS)

    Johnson, Erik; Benton, Eric; Stapels, Christopher; Chrsitian, James; Jie Chen, Xiao

    Available digital dosimeters are bulky and unable to provide real-time monitoring of dose from space radiation. The complexity of space-flight design requires reliable, fault-tolerant equip-ment capable of providing real-time dosimetry during a mission, which is not feasible with the existing thermoluminescent dosimeter (TLD) technology, especially during extravehicular activity (EVA). Real-time monitoring is important for low-Earth orbiting spacecraft and inter-planetary space flight to alert the crew when Solar Particle Events (SPE) increase the particle flux of the spacecraft environment. A dosimeter-on-a-chip for personal dosimetry is comprised of a tissue-equivalent scintillator coupled to a solid-state photomultiplier (SSPM) built using CMOS technology. The radiation sensitive component of the dosimeter is coupled to analog signal processing components and a microprocessor, which can maintain processing fidelity up to 5x105 events per second. The dynamic range of the dosimeter has been verified from 1-GeV protons (0.22 keV/µm in H20) to 420 MeV/n Fe (201.1 keV/µm in H20). The dosimeter confirmed doses to within 3

  7. Impact of the Fukushima nuclear accident on background radiation doses measured by control dosimeters in Japan.

    PubMed

    Romanyukha, Alexander; King, David L; Kennemur, Lisa K

    2012-05-01

    After the 9.0 magnitude earthquake and subsequent massive tsunami on 11 March 2011 in Japan, several reactors at the Fukushima Daiichi Nuclear Power Plant suffered severe damage. There was immediate participation of U.S. Navy vessels and other United States Department of Defense (DoD) teams that were already in the area at the time of the disaster or arrived shortly thereafter. The correct determination of occupational dose equivalent requires estimation of the background dose component measured by control dosimeters, which is subsequently subtracted from the total dose equivalent measured by personal dosimeters. The purpose of the control dosimeters is to determine the amount of radiation dose equivalent that has accumulated on the dosimeter from background or other non-occupational sources while they are in transit or being stored. Given the release of radioactive material and potential exposure to radiation from the Fukushima Daiichi Nuclear Power Plant and the process by which the U.S. Navy calculates occupational exposure to ionizing radiation, analysis of pre- and post-event control dosimeters is warranted. Several hundred historical dose records from the Naval Dosimetry Center (NDC) database were analyzed and compared with the post-accident dose equivalent data of control dosimeters. As result, it was shown that the dose contribution of the radiation and released radiological materials from the Fukushima nuclear accident to background radiation doses is less than 0.375 μSv d for shallow and deep photon dose equivalent. There is no measurable effect on neutron background exposure. The latter has at least two important conclusions. First, the NDC can use doses measured by control dosimeters at issuing sites in Japan for determination of personnel dose equivalents; second, the dose data from control dosimeters prior to and after the Fukushima accident may be used to assist in dose reconstruction of non-radiological (non-badged) personnel at these locations.

  8. Dosimeter and method for using the same

    DOEpatents

    Warner, Benjamin P.; Johns, Deidre M.

    2003-06-24

    A very sensitive dosimeter that detects ionizing radiation is described. The dosimeter includes a breakable sealed container. A solution of a reducing agent is inside the container. The dosimeter has an air-tight dosimeter body with a transparent portion and an opaque portion. The transparent portion includes a transparent chamber that holds the breakable container with the reducing agent. The opaque portion includes an opaque chamber that holds an emulsion of silver salt (AgX) selected from silver chloride, silver bromide, silver iodide, and combinations of them. A passageway in the dosimeter provides fluid communication between the transparent chamber and the opaque chamber. The dosimeter may also include a chemical pH indicator in the breakable container that provides a detectable color change to the solution for a pH of about 3-10. The invention also includes a method of detecting ionizing radiation that involves producing the dosimeter, breaking the breakable container, allowing the solution to flow through the passageway and contact the emulsion, detecting any color change in the solution and using the color change to determine a radiation dosage.

  9. Comparative sensitivity study and reading correction of various albedo dosimeters in neutron fields on the U-400M accelerator

    NASA Astrophysics Data System (ADS)

    Mokrov, Yu. V.; Morozov, S. V.; Shchegolev, V. Yu.

    2013-03-01

    The sensitivities of three types of albedo dosimeters are experimentally studied in U-400M accelerator radiation fields in the experimental hall (one point) and behind its shielding (three points). It is shown that the ratios of the sensitivity of the albedo dosimeter (AD) and the combined personal dosimeter (CPD) used earlier at the Joint Institute for Nuclear Research (JINR) to the sensitivity of the DVGN-01 dosimeter are constant within 25%. This allows the AD and CPD sensitivities obtained earlier at the JINR facilities to be used for correcting readings of the DVGN-01 now used at JINR for personal radiation monitoring. Correction coefficients are found for DVGN-01 readings behind the U-400M shielding. This has allowed a more reliable correction coefficient to be established for the Flerov Laboratory of Nuclear Reactions (FLNR).

  10. Radiation Monitoring Equipment Dosimeter Experiment

    NASA Technical Reports Server (NTRS)

    Hardy, Kenneth A.; Golightly, Michael J.; Quam, William

    1992-01-01

    Spacecraft crews risk exposure to relatively high levels of ionizing radiation. This radiation may come from charged particles trapped in the Earth's magnetic fields, charged particles released by solar flare activity, galactic cosmic radiation, energetic photons and neutrons generated by interaction of these primary radiations with spacecraft and crew, and man-made sources (e.g., nuclear power generators). As missions are directed to higher radiation level orbits, viz., higher altitudes and inclinations, longer durations, and increased flight frequency, radiation exposure could well become a major factor for crew stay time and career lengths. To more accurately define the radiological exposure and risk to the crew, real-time radiation monitoring instrumentation, which is capable of identifying and measuring the various radiation components, must be flown. This presentation describes a radiation dosimeter instrument which was successfully flown on the Space Shuttle, the RME-3.

  11. Comparative study of some new EPR dosimeters

    NASA Astrophysics Data System (ADS)

    Alzimami, K. S.; Maghraby, Ahmed M.; Bradley, D. A.

    2014-02-01

    Investigations have been made of four new radiation dosimetry EPR candidates from the same family of materials: sulfamic acid, sulfanillic acid, homotaurine, and taurine. Mass energy attenuation coefficients, mass stopping power values and the time dependence of the radiation induced radicals are compared. Also investigated are the microwave saturation behavior and the effect of applied modulation amplitude on both peak-to-peak line width (WPP) and peak-to-peak signal height (HPP). The dosimeters are characterized by simple spectra and stable radiation-induced radicals over reasonable durations, especially in taurine dosimeters. Sulfamic acid dosimeters possessed the highest sensitivity followed by taurine and homotaurine and sulfanillic.

  12. Diffusion properties of a radiochromic hydrogel dosimeter

    NASA Astrophysics Data System (ADS)

    Skyt, P. S.; Kinnari, T. S.; Wahlstedt, I.; Yates, E. S.; Muren, L. P.; Petersen, J. B. B.; Balling, P.

    2013-06-01

    The aim of this study was to investigate the diffusion properties of a radiochromic hydrogel dosimeter based on leuco malachite green dye in a gelatine matrix. One half of each dosimeter was irradiated while the other half was left un-irradiated creating dose gradients over which diffusion could be investigated. Read-out of the optical response was performed with a high-resolution optical scanner. The dosimeters were found to exhibit a low diffusion rate but a high auto-oxidation level leading to a fading of the contrast in the dose response with time.

  13. Solid state neutron dosimeter for space applications

    NASA Technical Reports Server (NTRS)

    Entine, Gerald; Nagargar, Vivek; Sharif, Daud

    1990-01-01

    Personnel engaged in space flight are exposed to significant flux of high energy neutrons arising from both primary and secondary sources of ionizing radiation. Presently, there exist no compact neutron sensor capable of being integrated in a flight instrument to provide real time measurement of this radiation flux. A proposal was made to construct such an instrument using special PIN silicon diode which has the property of being insensitive to the other forms of ionizing radiation. Studies were performed to determine the design and construction of a better reading system to allow the PIN diode to be read with high precision. The physics of the device was studied, especially with respect to those factors which affect the sensitivity and reproducibility of the neutron response. This information was then used to develop methods to achieve high sensitivity at low neutron doses. The feasibility was shown of enhancing the PIN diode sensitivity to make possible the measurement of the low doses of neutrons encountered in space flights. The new PIN diode will make possible the development of a very compact, accurate, personal neutron dosimeter.

  14. Skin autofluorescence as a biological UVR dosimeter.

    PubMed

    Sandby-Møller, J; Thieden, E; Philipsen, P A; Heydenreich, J; Wulf, H C

    2004-02-01

    Collagen is one of the major endogenous skin fluorophores. Alteration in the structure of collagen due to chronic ultraviolet radiation (UVR) exposure may influence the intensity of the autofluorescence. The aim of this study was to investigate the relation between collagen-linked autofluorescence and sun exposure to clarify whether the skin can be used as a biological UVR dosimeter. We conducted an in vivo study with 131 healthy volunteers. Fluorescence was measured from sun-exposed (dorsal forearm, forehead and shoulder) and sun-protected (buttock) skin and corrected for the impact of pigmentation and redness. The excitation wavelengths (Ex) and emission wavelengths (Em) were: Ex330:Em370, Ex330:Em455 and Ex370:Em455 nm. Individual UVR exposure data were collected both retrospectively and prospectively using questionnaires and electronic personal UVR dosimeters for a summer period. Age, but not sex, skin type or smoking habits correlated significantly positively with skin autofluorescence at Ex370:Em455 at all body sites (P<0.001, r(2)=0.08-0.26), and at Ex330:Em455 only at the buttock (P=0.001, r(2)=0.08), whereas age was not correlated with Ex330:Em370. Sun-protected buttock skin had significantly higher autofluorescence than sun-exposed skin (P-values<0.0001). Because of great between-subject differences in autofluorescence at different body sites, and because the autofluorescence at the unexposed buttock represents the baseline value, individual correction of skin autofluorescence measurement with that of the buttock was performed. Different measures of individual chronic cumulative UVR doses correlated significantly negatively with the skin autofluorescence ratio (F(ratio)), but the correlations were poor (r(2)=0.03-0.10). The results indicate that the collagen-linked skin F(ratio) might be best to use as a measure of individual photodamage, a UVR dose effect, and that it is also a better marker of individual cumulative UVR dose than the used UVR exposure

  15. The shelf life of dyed polymethylmethacrylate dosimeters

    NASA Astrophysics Data System (ADS)

    Bett, R.; Watts, M. F.; Plested, M. E.

    2002-03-01

    The long-term stability of the radiation response of Harwell Red 4034 and Amber 3042 Perspex Dosimeters has been monitored for more than 15 years, and the resulting data used in the justification of their shelf-life specifications.

  16. Performance criteria for dosimeter angular response

    SciTech Connect

    Roberson, P.L.; Fox, R. A.; Cummings, F. M.; McDonald, J. C.; Jones, K.L.

    1988-06-01

    This report provides criteria for evaluating the response of personnel dosimeters to radiation at nonperpendicular incidence. The US Department of Energy Laboratory Accreditation Program (DOELAP) ensures that dosimetry systems at DOE facilities meet acceptable standards for precision and accuracy. In the past, these standards were limited to tests for system variability, energy dependence, and level of detection. The proposed criteria will broaden the scope of DOELAP to include the angular response of personnel dosimeters. Because occupational exposures in the workplace are rarely due to radiation from only one direction, dosimeters must accurately assign individual dose equivalent from irradiation at any forward angle of incidence. Including an angular response criterion in DOELAP would improve the quality of personnel monitoring provided that the criterion is developed from appropriate dose quantities. This report provides guidance for assigning individual dose equivalents for radiation fields at nonperpendicular incidence to the dosimeter. 21 refs., 10 figs., 10 tabs.

  17. Use of wrist albedo neutron dosimeters

    SciTech Connect

    Hankins, D.E.

    1983-01-01

    We are developing a wrist dosimeter that can be used to measure the exposure at the wrist to x-rays, gamma rays, beta-particles, thermal neutrons and fast neutrons. It consists of a modified Hankins Type albedo neutron dosimeter and also contains three pieces of CR-39 plastic. ABS plastic in the form of an elongated hemisphere provides the beta and low energy x-ray shielding necessary to meet the requirement of depth dose measurements at 1 cm. The dosimeter has a beta window located in the side of the hemisphere oriented towards an object being held in the hands. A TLD 600 is positioned under the 1 cm thick ABS plastic and is used to measure the thermal neutron dose. At present we are using Velcro straps to hold the dosimeter on the inside of the wrist. 9 figures.

  18. Intercomparison of high energy neutron personnel dosimeters

    SciTech Connect

    McDonald, J.C.; Akabani, G.; Loesch, R.M.

    1993-03-01

    An intercomparison of high-energy neutron personnel dosimeters was performed to evaluate the uniformity of the response characteristics of typical neutron dosimeters presently in use at US Department of Energy (DOE) accelerator facilities. It was necessary to perform an intercomparison because there are no national or international standards for high-energy neutron dosimetry. The testing that is presently under way for the Department of Energy Laboratory Accreditation Program (DOELAP) is limited to the use of neutron sources that range in energy from about 1 keV to 2 MeV. Therefore, the high-energy neutron dosimeters presently in use at DOE accelerator facilities are not being tested effectively. This intercomparison employed neutrons produced by the {sup 9}Be(p,n){sup 9}B interaction at the University of Washington cyclotron, using 50-MeV protons. The resulting neutron energy spectrum extended to a maximum of approximately 50-MeV, with a mean energy of about 20-MeV. Intercomparison results for currently used dosimeters, including Nuclear Type A (NTA) film, thermoluminescent dosimeter (TLD)-albedo, and track-etch dosimeters (TEDs), indicated a wide variation in response to identical doses of high-energy neutrons. Results of this study will be discussed along with a description of plans for future work.

  19. Early development and characterization of a DNA-based radiation dosimeter

    NASA Astrophysics Data System (ADS)

    Avarmaa, Kirsten A.

    It is the priority of first responders to minimize damage to persons and infrastructure in the case of a nuclear emergency due to an accident or deliberate terrorist attack -- if this emergency includes a radioactive hazard, first responders require a simple-to-use, accurate and complete dosimeter for radiation protection purposes in order to minimize the health risk to these individuals and the general population at large. This work consists of the early evaluation of the design and performance of a biologically relevant dosimeter which uses DNA material that can respond to the radiation of any particle type. The construct consists of fluorescently tagged strands of DNA. The signalling components of this dosimeter are also investigated for their sensitivity to radiation damage and light exposure. The dual-labelled dosimeter that is evaluated in this work gave a measurable response to gamma radiation at dose levels of 10 Gy for the given detector design and experimental setup. Further testing outside of this work confirmed this finding and indicated a working range of 100 mGy to 10 Gy using a custom-built fluorimeter as part of a larger CRTI initiative. Characterization of the chromatic components of the dosimeter showed that photobleaching is not expected to have an effect on dosimeter performance, but that radiation can damage the non-DNA signalling components at higher dose levels, although this damage is minimal at lower doses over the expected operating ranges. This work therefore describes the early steps in the quantification of the behaviour of the DNA dosimeter as a potential biologically-based device to measure radiation dose.

  20. PNNL Results from 2009 Silene Criticality Accident Dosimeter Intercomparison Exercise

    SciTech Connect

    Hill, Robin L.; Conrady, Matthew M.

    2010-06-30

    This document reports the results of testing of the Hanford Personnel Nuclear Accident Dosimeter (PNAD) during a criticality accident dosimeter intercomparison exercise at the CEA Valduc Center on October 13, 14, and 15, 2009.

  1. Solid state neutron dosimeter for space applications

    SciTech Connect

    Nagarkar, V.; Entine, G.; Stoppel, P.; Cirignano, L. ); Swinehart, P. )

    1992-08-01

    One of the most important contributions to the radiation exposure of astronauts engaged in space flight is the significant flux of high energy neutrons arising from both primary and secondary sources of ionizing radiation. Under NASA sponsorship, the authors are developing a solid state neutron sensor capable of being incorporated into a very compact, flight instrument to provide high quality real time measurement of this important radiation flux. The dosimeter uses a special, high neutron sensitivity, PIN diode that is insensitive t the other forms of ionizing radiation. The dosimeter will have the ability to measure and record neutron dose over a range of 50 microgray to tens of milligrays (5 millirads to several rads) over a flight of up to 30 days. the performance characteristics of the PIN diode with a detailed description of the overall dosimeter is presented. in this paper.

  2. System for use with solid state dosimeter

    DOEpatents

    Miller, Steven D.; McDonald, Joseph C.; Eichner, Fred N.; Tomeraasen, Paul L.

    1990-01-01

    The present invention constitutes a system for determining the amounts of ionizing radiation to which dosimeters using thermoluminescent materials have been exposed. In accordance with this system, the thermoluminescent materials which comprise the dosimeters are first cooled by contact with a cryogenic substance such as liquified nitrogen. The thermoluminescent materials are then optically stimulated by exposure to ultraviolet light. Thereafter, the amounts of visible light emitted by the thermoluminescent materials are detected and counted as the materials are allowed to warm up to room temperature. The amounts of luminescence exhibited by the materials are related to radiation exposure and provide a sensitive measure of radiation dosage. It has been discovered that the above procedure is most effective when heavily doped thermoluminescent materials are used and that the procedure allows many useful plastic materials to now be employed in dosimeter constructions.

  3. System for use with solid state dosimeter

    DOEpatents

    Miller, S.D.; McDonald, J.C.; Eichner, F.N.; Tomeraasen, P.L.

    1990-09-04

    The present invention constitutes a system for determining the amounts of ionizing radiation to which dosimeters using thermoluminescent materials have been exposed. In accordance with this system, the thermoluminescent materials which comprise the dosimeters are first cooled by contact with a cryogenic substance such as liquefied nitrogen. The thermoluminescent materials are then optically stimulated by exposure to ultraviolet light. Thereafter, the amounts of visible light emitted by the thermoluminescent materials are detected and counted as the materials are allowed to warm up to room temperature. The amounts of luminescence exhibited by the materials are related to radiation exposure and provide a sensitive measure of radiation dosage. It has been discovered that the above procedure is most effective when heavily doped thermoluminescent materials are used and that the procedure allows many useful plastic materials to now be employed in dosimeter constructions. 3 figs.

  4. Environmental dosimeter of the thermoluminescent type

    DOEpatents

    Eichner, F.N.; Kocher, L.F.

    1974-01-29

    A dosimeter for accurately monitoring normally low-energy radiation including a thermoluminescent CaF phosphor enclosed within a tantalum capsule is described. The tantalum acts as a filter to weaken the measured dose due to photons having energies below about 0.2 MeV. Tantalum end caps are maintained on the capsule body by a polyolefin sheath formed from heat-contractable tubing. After exposing the dosimeter to environmental radiation, it is placed in a shielded chamber for about 24 h and subsequently annealed at about 80 deg C to release radiation energy accumulated in low-temperature traps. The dosimeter is then disassembled and the phosphors photometrically read at temperatures about 50 deg C to determine the absorbed radiation dose. (Official Gazette)

  5. New radiation dosimeter using a pyroelectric detector

    SciTech Connect

    de Paula, M.H.; Carvalho, A.A.; Mascarenhas, S.; Zimmerman, R.L.

    1984-11-01

    We describe a new type of radiation dosimeter, for the diagnostic x-ray region, using a pyroelectric detector. It consists of a PZT ceramic crystal thick enough to absorb all the incident radiation at 33 keV. This pyroelectric radiation dosimeter (PERD) produces an electrical signal when exposed to a chopped beam of x-ray photons. The PERD is basically a microcalorimeter. It has the following characteristics: (1) it responds linearly to the energy fluence rate of the radiation; (2) it responds linearly to the radiation inten

  6. New radiation dosimeter using a pyroelectric detector

    SciTech Connect

    de Paula, M.H.; Carvalho, A.A.; Mascarenhas, S.; Zimmerman, R.L.

    1984-11-01

    We describe a new type of radiation dosimeter, for the diagnostic x-ray region, using a pyroelectric detector. It consists of a PZT ceramic crystal thick enough to absorb all the incident radiation at 33 keV. This pyroelectric radiation dosimeter (PERD) produces an electrical signal when exposed to a chopped beam of x-ray photons. The PERD is basically a microcalorimeter. It has the following characteristics: (1) it responds linearly to the energy fluence rate of the radiation; (2) it responds linearly to the radiation intensity for a given radiation spectrum; (3) it has excellent stability; (4) it is simple to construct and inexpensive; and (5) it is rugged.

  7. Chemical Dosimeter Tube With Coaxial Sensing Rod

    NASA Technical Reports Server (NTRS)

    Lueck, Dale E.

    1993-01-01

    Improved length-of-stain (LOS) chemical dosimeter indicates total dose of chemical vapor in air. Made with rods and tubes of various diameters to obtain various sensitivities and dynamic ranges. Sensitivity larger and dose range smaller when more room for diffusion in gap between tube and rod. Offers greater resistance to changing of color of exposed dye back to color of unexposed condition, greater sensitivity, and higher degree of repeatability. Developed to measure doses of gaseous HCI, dosimeter modified by use of other dyes to indicate doses of other chemical vapors.

  8. Fiber optic dosimeter with silicon photomultipliers

    NASA Astrophysics Data System (ADS)

    Moutinho, L. M.; Castro, I. F.; Peralta, L.; Abreu, M. C.; Veloso, J. F. C. A.

    2014-08-01

    A small dimension, real-time readout dosimeter is desirable for specific applications in medical physics as for example, dose measurement in prostate brachytherapy. This particular radiotherapy procedure consists in the permanent deposition of low energy, low-dose and low-dose rate small sized radioactive seeds. We developed a scintillating fiber optic based dosimeter suitable for in-vivo, real-time low dose and low dose rate measurements. Due to the low scintillation light produced in the scintillating fiber, a high sensitive and high gain light detector is required. The Silicon Photomultipliers are an interesting option that allowed us to obtain good results in our studies.

  9. DEPRON dosimeter for ``Lomonosov'' satellite

    NASA Astrophysics Data System (ADS)

    Brilkov, Ivan; Vedenkin, Nikolay; Panasyuk, Mikhail; Amelyushkin, Aleksandr; Petrov, Vasily; Nechayev, Oleg; Benghin, Victor

    appearance of the instrument DEPRON (Dosimeter of Electrons, PROtons and Neutrons) was determined. DEPRON is intended for registration of the absorbed doses and linear energy transfer spectra for high-energy electrons, protons and nuclei of space radiation, as well as registration of thermal and slow neutrons. The experiment based on DEPRON instrument is aimed at the studies of the distribution of space radiation dose rate at high latitude paths in order to study the flight paths of perspective manned spacecraft. Present work provides a brief description of the DEPRON instrument, its calibration results and the structure of the output data.

  10. Response characteristics of selected personnel neutron dosimeters

    SciTech Connect

    McDonald, J.C.; Fix, J.J.; Hadley, R.T.; Holbrook, K.L.; Yoder, R.C.; Roberson, P.L.; Endres, G.W.R.; Nichols, L.L.; Schwartz, R.B.

    1983-09-01

    Performance characteristics of selected personnel neutron dosimeters in current use at Department of Energy (DOE) facilities were determined from their evaluation of neutron dose equivalent received after irradiations with specific neutron sources at either the National Bureau of Standards (NBS) or the Pacific Northwest Laboratory (PNL). The characteristics assessed included: lower detection level, energy response, precision and accuracy. It was found that when all of the laboratories employed a common set of calibrations, the overall accuracy was approximately +-20%, which is within uncertainty expected for these dosimeters. For doses above 80 mrem, the accuracy improved to better than 10% when a common calibration was used. Individual differences found in this study may reflect differences in calibration technique rather than differences in the dose rates of actual calibration standards. Second, at dose rates above 100 mrem, the precision for the best participants was generally below +-10% which is also within expected limits for these types of dosimeters. The poorest results had a standard deviation of about +-25%. At the lowest doses, which were sometimes below the lower detection limit, the precision often approached or exceeded +-100%. Third, the lower level of detection for free field /sup 252/Cf neutrons generally ranged between 20 and 50 mrem. Fourth, the energy dependence study provided a characterization of the response of the dosimeters to neutron energies far from the calibration energy. 11 references, 22 figures, 26 tables.

  11. Analysis of nonstandard noise dosimeter microphone positions.

    PubMed

    Byrne, David C; Reeves, Efrem R

    2008-03-01

    This study was conducted as part of a project involving the evaluation of a new type of noise exposure monitoring paradigm. Laboratory tests were conducted to assess how "nonstandard" dosimeter microphones and microphone positions measured noise levels under different acoustical conditions (i.e., diffuse field and direct field). The data presented in this article reflect measurement differences due to microphone position and mounting/supporting structure only and are not an evaluation of any particular complete dosimeter system. To varying degrees, the results obtained with the dosimeter microphones used in this study differed from the reference results obtained in the unperturbed (subject absent) sound field with a precision (suitable for use in an ANSI Type 1 sound level meter) (1)/(2)-inch (12.7 mm) measurement microphone. Effects of dosimeter microphone placement in a diffuse field were found to be minor for most of the test microphones/locations, while direct field microphone placement effects were found to be quite large depending on the microphone position and supporting structure, sound source location, and noise spectrum.

  12. Underwater remote-reading dosimeter evaluation

    SciTech Connect

    Clow, H.E.; Emmons, G. )

    1985-01-01

    This paper reports on problems inherent in attempting to measure underwater dose rates and monitor and control diver exposures. At Connecticut Yankee, the authors had a specific procedure in effect to cover diving evolutions; however, the authors were not satisfied with the methods available to us for monitoring a diver's dose during a dive. The authors looked around and discovered that the ideal monitoring method was already at hand. In the past, the authors had successfully used the Xetex 503A Teledose system for high dose rate jobs under are variety of circumstances, but not underwater. The basic Teledose system consists of a base station and five individual electronic dosimeter/transmitters that can be worn by workers. The dosimeters are GM-tube types packaged in high-impact plastic or metal cases, each powered by a single 9-volt battery. The dosimeters do not have their own read-outs - instead, they transmit a coded pulse for each mR detected via a loop antenna to the base station, where the accumulated exposure for each of the five dosimeter units is displayed.

  13. Pen Ink as an Ultraviolet Dosimeter

    ERIC Educational Resources Information Center

    Downs, Nathan; Turner, Joanna; Parisi, Alfio; Spence, Jenny

    2008-01-01

    A technique for using highlighter ink as an ultraviolet dosimeter has been developed for use by secondary school students. The technique requires the students to measure the percentage of colour fading in ink drawn onto strips of paper that have been exposed to sunlight, which can be calibrated to measurements of the ultraviolet irradiance using…

  14. Pen Ink as an Ultraviolet Dosimeter

    ERIC Educational Resources Information Center

    Downs, Nathan; Turner, Joanna; Parisi, Alfio; Spence, Jenny

    2008-01-01

    A technique for using highlighter ink as an ultraviolet dosimeter has been developed for use by secondary school students. The technique requires the students to measure the percentage of colour fading in ink drawn onto strips of paper that have been exposed to sunlight, which can be calibrated to measurements of the ultraviolet irradiance using…

  15. Radiant energy dosimeter for field use

    Treesearch

    A. Broido; A.W. McMasters

    1967-01-01

    Thermal radiation measurements in Project Flambeau fires involved a limited number of conventional radiometers located outside the fire periphery. A simple, cheap, easily-fabricated, light-weight, self-contained, rugged dosimeter was desired to withstand a hot fire environment, including a specific energy input of 5,000 cal cm -2, and to record...

  16. Compton effect thermally activated depolarization dosimeter

    DOEpatents

    Moran, Paul R.

    1978-01-01

    A dosimetry technique for high-energy gamma radiation or X-radiation employs the Compton effect in conjunction with radiation-induced thermally activated depolarization phenomena. A dielectric material is disposed between two electrodes which are electrically short circuited to produce a dosimeter which is then exposed to the gamma or X radiation. The gamma or X-radiation impinging on the dosimeter interacts with the dielectric material directly or with the metal composing the electrode to produce Compton electrons which are emitted preferentially in the direction in which the radiation was traveling. A portion of these electrons becomes trapped in the dielectric material, consequently inducing a stable electrical polarization in the dielectric material. Subsequent heating of the exposed dosimeter to the point of onset of ionic conductivity with the electrodes still shorted through an ammeter causes the dielectric material to depolarize, and the depolarization signal so emitted can be measured and is proportional to the dose of radiation received by the dosimeter.

  17. Strategies for millirad sensitivity in PMOS dosimeters

    SciTech Connect

    Conneely, C.; O`Connell, B.; Hurley, P.; Lane, W.; Adams, L.

    1998-06-01

    Previous work at this center has shown enhanced sensitivity for PMOS dosimeters using a design approach. This is being extended presently to longer chains of devices. Prior to this extension, thermal effects have been investigated and a noise analysis has been undertaken. The need for a temperature compensation technique becomes imperative if the signal/noise ratio is to be improved.

  18. Investigating hydrogel dosimeter decomposition by chemical methods

    NASA Astrophysics Data System (ADS)

    Jordan, Kevin

    2015-01-01

    The chemical oxidative decomposition of leucocrystal violet micelle hydrogel dosimeters was investigated using the reaction of ferrous ions with hydrogen peroxide or sodium bicarbonate with hydrogen peroxide. The second reaction is more effective at dye decomposition in gelatin hydrogels. Additional chemical analysis is required to determine the decomposition products.

  19. Polymer gel dosimeter based on itaconic acid.

    PubMed

    Mattea, Facundo; Chacón, David; Vedelago, José; Valente, Mauro; Strumia, Miriam C

    2015-11-01

    A new polymeric dosimeter based on itaconic acid and N, N'-methylenebisacrylamide was studied. The preparation method, compositions of monomer and crosslinking agent and the presence of oxygen in the dosimetric system were analyzed. The resulting materials were irradiated with an X-ray tube at 158cGy/min, 226cGymin and 298cGy/min with doses up to 1000Gy. The dosimeters presented a linear response in the dose range 75-1000Gy, sensitivities of 0.037 1/Gyat 298cGy/min and an increase in the sensitivity with lower dose rates. One of the most relevant outcomes in this study was obtaining different monomer to crosslinker inclusion in the formed gel for the dosimeters where oxygen was purged during the preparation method. This effect has not been reported in other typical dosimeters and could be attributed to the large differences in the reactivity among these species. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Energy dependence measurement of small-type optically stimulated luminescence (OSL) dosimeter by means of characteristic X-rays induced with general diagnostic X-ray equipment.

    PubMed

    Takegami, Kazuki; Hayashi, Hiroaki; Okino, Hiroki; Kimoto, Natsumi; Maehata, Itsumi; Kanazawa, Yuki; Okazaki, Tohru; Hashizume, Takuya; Kobayashi, Ikuo

    2016-01-01

    For X-ray inspections by way of general X-ray equipment, it is important to measure an entrance-skin dose. Recently, a small optically stimulated luminescence (OSL) dosimeter was made commercially available by Landauer, Inc. The dosimeter does not interfere with the medical images; therefore, it is expected to be a convenient detector for measuring personal exposure doses. In an actual clinical situation, it is assumed that X-rays of different energies will be detected by a dosimeter. For evaluation of the exposure dose measured by a dosimeter, it is necessary to know the energy dependence of the dosimeter. Our aim in this study was to measure the energy dependence of the OSL dosimeter experimentally in the diagnostic X-ray region. Metal samples weighing several grams were irradiated and, in this way, characteristic X-rays having energies ranging from 8 to 85 keV were generated. Using these mono-energetic X-rays, the dosimeter was irradiated. Simultaneously, the fluence of the X-rays was determined with a CdTe detector. The energy-dependent efficiency of the dosimeter was derived from the measured value of the dosimeter and the fluence. Moreover, the energy-dependent efficiency was calculated by Monte-Carlo simulation. The efficiency obtained in the experiment was in good agreement with that of the simulation. In conclusion, our proposed method, in which characteristic X-rays are used, is valuable for measurement of the energy dependence of a small OSL dosimeter in the diagnostic X-ray region.

  1. Characterization of a medical X-ray machine for testing the response of electronic dosimeters in pulsed radiation fields

    NASA Astrophysics Data System (ADS)

    Guimarães, Margarete C.; Da Silva, Teógenes A.

    2014-11-01

    Electronic personal dosimeters (EPD) based on solid state detectors have been used for personnel monitoring for radiation protection purpose; their use has been extended to practices with pulsed radiation beams although their performance is not well known. Deficiencies in the EPD response in pulsed radiation fields have been reported; they were not detected before since type tests and calibrations of EPDs were established in terms of continuous X and gamma reference radiations. An ISO working group was formed to elaborate a standard for test conditions and performance requirements of EPDs in pulsed beams; the PTB/Germany implemented a special X-ray facility for generating the reference pulsed radiation beams. In this work, an 800 Plus VMI medical X-ray machine of the Dosimeter Calibration Laboratory of CDTN/CNEN was characterized to verify its feasibility to perform EPD tests. Characterization of the x-ray beam was done in terms of practical peak voltage, half-value layer, mean energy and air kerma rate. Reference dosimeters used for air kerma measurements were verified as far their metrological coherence and a procedure for testing EDPs was established. Electronic personal dosimeters (EPD) have been used for personnel monitoring. EPD use has been extended to pulsed radiation beams. Deficiencies in the EPD response in pulsed beams have been reported. The feasibility of using a medical X-ray machine to perform EPD tests was studied. Reference dosimeters were verified and EPD testing procedure was established.

  2. Studies on new neutron-sensitive dosimeters using an optically stimulated luminescence technique

    NASA Astrophysics Data System (ADS)

    Kulkarni, M. S.; Luszik-Bhadra, M.; Behrens, R.; Muthe, K. P.; Rawat, N. S.; Gupta, S. K.; Sharma, D. N.

    2011-07-01

    The neutron response of detectors prepared using α-Al 2O 3:C phosphor developed using a melt processing technique and mixed with neutron converters was studied in monoenergetic neutron fields. The detector pellets were arranged in two different pairs: α-Al 2O 3:C + 6LiF/α-Al 2O 3:C + 7LiF and α-Al 2O 3:C + high-density polyethylene/α-Al 2O 3:C + Teflon, for neutron dosimetry using albedo and recoil proton techniques. The optically stimulated luminescence response of the Al 2O 3:C + 6,7LiF dosimeter to radiation from a 252Cf source was 0.21, in terms of personal dose equivalent Hp(10) and relative to radiation from a 137Cs source. This was comparable to results obtained with similar detectors prepared using commercially available α-Al 2O 3:C phosphor. The Hp(10) response of the α-Al 2O 3:C + 6,7LiF dosimeters was found to decrease by more than two orders of magnitude with increasing neutron energy, as expected for albedo dosimeters. The response of the α-Al 2O 3:C + high-density polyethylene/α-Al 2O 3:C + Teflon dosimeters was small, of the order of 1% to 2% in terms of Hp(10) and relative to radiation from a 137Cs source, for neutron energies greater than 1 MeV.

  3. A BCCD-based dosimeter for mixed radiation fields

    NASA Astrophysics Data System (ADS)

    Pierschel, M.; Ehwald, K.-E.; Heinemann, B.; Januschewski, F.; Schmitz, T.; Schröder, O.

    1993-03-01

    The development of a personal dosimeter based on a BCCD-detector for mixed neutron and gamma radiation in the energy range from thermal energy to 20 MeV for neutrons respectively 30 keV to a few MeV for gammas will be presented. The detector has to give information on the total radiation dose, D, and on the radiation quality. Both peaces of information are required to determine the directional dose equivalent. The basic radiation physics requirements for the detector as well as a concept of a buried channel CCD-matrix for radiation applications including the technology process will be described. A two dimensional device simulation package was used for both optimization of the charge storage nodes including free charge transfer and the basic electronic processes depending on radiation interaction with silicon.

  4. [AOR characterization and zoning: a dosimeter for blue light].

    PubMed

    Dario, R; Uva, J; Di Lecce, V; Quarto, A

    2011-01-01

    The paper presents the results obtained thanks to an innovative experimental device for the assessment of artificial optical radiation (AOR) exposure in workplace. This . device was developed by 'Politecnico di Bari-DIASS'. The wearable personal dosimeter has three sensors: one is used for measuring head position/movement, therefore there is a color light sensor to determine the AOR and finally there is a video camera to localize sources. Our system is connected to a netbook via USB cable that allows one to obtain the real and extimated value of worker's exposure, also with "augmented reality". The aim of this paper is realizing work place safety zoning for the classifacation of not only specific dangerous areas through the analysis of overlapping information from the device.

  5. Exploring the dose response of radiochromic dosimeters

    NASA Astrophysics Data System (ADS)

    Skyt, P. S.; Wahlstedt, I.; Yates, E. S.; Muren, L. P.; Petersen, J. B. B.; Balling, P.

    2013-06-01

    The aim of this study was to explore the dose response of a newly developed radio-chromic hydrogel dosimeter based on leuco malachite green dye in a gelatine matrix. The original dosimeter composition was first investigated in terms of dose response and dose-rate dependence. In addition, the initiating compounds producing chlorine radicals were substituted with compounds producing fluorine radicals, oxygen-centered radicals, carbon-centered radicals and bromine radicals. Also the surfactant was substituted by other compounds of different molecular size and charge. The original composition gave a dose response of 3.5·10-3 Gy-1cm-1 at 6 Gy/min with a dose rate dependence giving a 27 % increase when decreasing the dose rate to 1 Gy/min. None of the substituted initiating components contributed to an increase in dose response while only one surfactant increased the dose response slightly.

  6. Radiological properties of normoxic polymer gel dosimeters

    SciTech Connect

    Venning, A.J.; Nitschke, K.N.; Keall, P.J.; Baldock, C.

    2005-04-01

    The radiological properties of the normoxic polymer gel dosimeters MAGIC, MAGAS, and MAGAT [methacrylic and ascorbic acid in gelatin initiated by copper; methacrylic acid gelatine gel with ascorbic acid; and methacrylic acid gelatine and tetrakis (hydroxymethyl) phosphonium chloride, respectively] have been investigated. The radiological water equivalence was determined by comparing the polymer gel macroscopic photon and electron interaction cross sections over the energy range from 10 keV to 20 MeV and by Monte Carlo modeling of depth doses. Normoxic polymer gel dosimeters have a high gelatine and monomer concentration and therefore mass density (kg m{sup -3}) up to 3.8% higher than water. This results in differences between the cross-section ratios of the normoxic polymer gels and water of up to 3% for the attenuation, energy absorption, and collision stopping power coefficient ratios through the Compton dominant energy range. The mass cross-section ratios were within 2% of water except for the mass attenuation and energy absorption coefficients ratios, which showed differences with water of up to 6% for energies less than 100 keV. Monte Carlo modeling was undertaken for the polymer gel dosimeters to model the electron and photon transport resulting from a 6 MV photon beam. The absolute percentage differences between gel and water were within 1% and the relative percentage differences were within 3.5%. The results show that the MAGAT gel formulation is the most radiological water equivalent of the normoxic polymer gel dosimeters investigated due to its lower mass density measurement compared with MAGAS and MAGIC gels.

  7. Performance Evaluation of a Colorimetric Hydrazine Dosimeter

    DTIC Science & Technology

    1994-06-16

    air has been developed. The passive badge consists of a dosimeter card containing a vanillin solution coated on a thin paper substrate. The active...patch consists of a thick cellulose substrate coated with a vanillin solution. When placed in a plastic sample holder attached to a personnel pump, up to...5 L/min can be drawn through the active badge substrate. Through a condensation reaction, vanillin reacts with hydrazine to form a colored product

  8. Post-Irradiation Study of the Alanine Dosimeter

    PubMed Central

    Desrosiers, Marc F.

    2014-01-01

    Post-irradiation stability of high-dose dosimeters has traditionally been an important measurement influence quantity. Though the exceptional stability of the alanine dosimeter response with time has rendered this factor a non-issue for routine work, the archival quality of the alanine dosimeter has not been characterized. Here the alanine pellet dosimeter response is measured up to seven years post-irradiation for a range of absorbed doses. This long-term study is accompanied by an examination of the environmental influence quantities (e.g., ambient light) on the relatively short-term (3–4 month) stability of both pellet and film commercial dosimeters. Both dosimeter types demonstrated exceptional stability in the short term and proved to be relatively insensitive to common influence quantities. The long-term data revealed a complex dose-dependent response trend. PMID:26601033

  9. Hanford beta-gamma personnel dosimeter prototypes and evaluation

    SciTech Connect

    Fix, J.J.; Holbrook, K.L.; Soldat, K.L.

    1983-04-01

    Upgraded and modified Hanford dosimeter prototypes were evaluated for possible use at Hanford as a primary beta-gamma dosimeter. All prototypes were compatible with the current dosimeter card and holder design, as well as processing with the automated Hanford readers. Shallow- and deep-dose response was determined for selected prototypes using several beta sources, K-fluorescent x rays and filtered x-ray techniques. All prototypes included a neutron sensitive chip. A progressive evaluation of the performance of each of the upgrades to the current dosimeter is described. In general, the performance of the current dosimeter can be upgraded using individual chip sensitivity factors to improve precision and an improved algorithm to minimize bias. The performance of this dosimeter would be adequate to pass all categories of the ANSI N13.11 performance criteria for dosimeter procesors, provided calibration techniques compatible with irradiations adopted in the standard were conducted. The existing neutron capability of the dosimeter could be retained. Better dosimeter performance to beta-gamma radiation can be achieved by modifying the Hanford dosimeter so that four of the five chip positions are devoted to calculating these doses instead of the currently used two chip positions. A neutron sensitive chip was used in the 5th chip position, but all modified dosimeter prototypes would be incapable of discriminating between thermal and epithermal neutrons. An improved low energy beta response can be achieved for the current dosimeter and all prototypes considered by eliminating the security credential. Further improvement can be obtained by incorporating the 15-mil thick TLD-700 chips.

  10. Standard Procedure for Calibrating an Areal Calorimetry Based Dosimeter

    DTIC Science & Technology

    2015-05-01

    provided to assist in calibrating other dosimeters. 15. SUBJECT TERMS Millimeter waves, dosimeter, calorimeter, CLT, Carbon-loaded Teflon 16. SECURITY...Bioeffects Branch CL Center Left CLT Carbon-loaded Teflon CR Center Right GPIB General Purpose Interface Bus IR Infrared LC Lower Center...used carbon-loaded Teflon ® (CLT) as the radio frequency (RF) absorber for the dosimeter. The methodology presented will use CLT for the calibration

  11. Comparison of the fiber optic dosimeter and semiconductor dosimeter for use in diagnostic radiology

    NASA Astrophysics Data System (ADS)

    Yoo, W. J.; Shin, S. H.; Sim, H. I.; Hong, S.; Kim, S. G.; Jang, J. S.; Kim, J. S.; Jeon, H. S.; Kwon, G. W.; Jang, K. W.; Cho, S.; Lee, B.

    2014-05-01

    A fiber-optic dosimeter (FOD) was fabricated using a plstic scintillating fiber, a plastic optical fiber, and a multi-pixel photon counter to measure entrance surface dose (ESD) in diagnostic radiology. Under changing tube current and irradition time of the digital radiography (DR) system, we measured the scintillating light and the ESD simultaneously. As experiemtnal results, the total counts of the FOD were changed in a manner similar to the ESDs of the semiconductor dosimeter (SCD). In conclusion, we demonstrated that the proposed FOD minimally affected the diagnostic information of DR image while the SCD caused serious image artifacts.

  12. GAMMA AND X-RAY DOSIMETER AND DOSIMETRIC METHOD

    DOEpatents

    Taplin, G.V.; Douglas, C.H.; Sigoloff, S.C.

    1958-08-19

    An improvement in colorimetric gamma and x-ray dosimeter systems and a self-contained. hand carried dostmeter of the afore-mentioned type ts described. A novel point of the invention ltes in the addition of specific quantities of certain normalizing agents to the two phase chlorinated hydro-carbon-aqueous dyc colortmetric dosimeter to eliminate the after reaction and thereby extend the utility of such systein. The structure of the two phase colorimetric dosimeter tubes and the carrying case for the tubes of the portable dosimeter are unique features.

  13. A CCD-based γ-ray dosimeter

    NASA Astrophysics Data System (ADS)

    Harris, E. J.; Royle, G. J.; Mooney, M. J.; Speller, R. D.

    2001-02-01

    This paper investigates the use of charged coupled devices (CCDs) for personal γ-ray dosimetry. Personal dosimeters require high sensitivity to the photon energies likely to be encountered and a sensitivity response across a wide dose rate range, particularly at low dose rates. The principal advantages of CCDs for this application are two-fold: sensitivity at low dose rates due to low-noise operation and a wide dynamic range. Preliminary experimental measurements have been performed on a standard buried channel CCD using a range of isotope sources. One half of the sensor was coated with a 100 μm thick layer of caesium iodide. It is proposed that the differing properties of the two halves of the sensor increases its range for personal dosimetry. Deposition of scintillator coatings of various thicknesses across the surface of the sensor should provide sensitivity to a wide energy range. The results demonstrated that the device has potential for this application. A linear dose rate response was observed over the dose rate range 0.08-35 μSv h -1. It was found that the uncoated side of the sensor demonstrated better response at low dose rates and a better energy response. Whereas the scintillator coated side would improve the detection efficiency at energies beyond 60 keV.

  14. Angular dependence of a simple accident dosimeter

    SciTech Connect

    Devine, R. T.; Romero, L. L.; Olsher, R. H.

    2004-01-01

    A simple dosimeter made of a sulfur tablet, bare and cadmium covered indium foils and a cadmium covered copper foil has been modeled using MCNP5. Studies of the model without phantom or other confounding factors have shown that the cross sections and fluence-to-dose factors generated by the Monte Carlo method agree with those generated by analytic expressions for the high energy component. The threshold cross sections for the detectors on a phantom were calculated. The resulting doses assigned agree well with exposures made to three critical assemblies. In this study the angular dependence on a phantom is studied and compared with measurements taken on the GODIVA reactor. The dosimeter positions on the phantom are facing the source, on the back and the side. In previous papers the modeling of a simple dosimeter made of a sulfur tablet, bare and cadmium covered indium foils and a cadmium covered copper foil has been modeled using MCNP5. The conclusion made was that most of the neutron dose from criticality assemblies results from the high energy neutron fluences determined by the sulfur and indium detectors. The results using doses measured from the GODIVA, SHEBA, and bare and lead shielded SILENE reactors confirmed this. The angular dependence of an accident dosemeter is of interest in evaluating the exposure of personnel. To investigate this effect accident dosemeters were placed on a phantom and exposed to the GODIVA reactor at phantom orientations of 0{sup o}, 45{sup o}, 90{sup o}, 135{sup o}, and 180{sup o} to the assembly center line.

  15. Real-time optical fiber dosimeter probe

    NASA Astrophysics Data System (ADS)

    Croteau, André; Caron, Serge; Rink, Alexandra; Jaffray, David; Mermut, Ozzy

    2011-03-01

    There is a pressing need for a passive optical fiber dosimeter probe for use in real-time monitoring of radiation dose delivered to clinical radiation therapy patients. An optical fiber probe using radiochromic material has been designed and fabricated based on a thin film of the radiochromic material on a dielectric mirror. Measurements of the net optical density vs. time before, during, and after irradiation at a rate of 500cGy/minute to a total dose of 5 Gy were performed. Net optical densities increased from 0.2 to 2.0 for radiochromic thin film thicknesses of 2 to 20 μm, respectively.

  16. A novel structure optical fiber radiation dosimeter for radiotherapy applications

    NASA Astrophysics Data System (ADS)

    Sun, Weimin; Qin, Zhuang; Ma, Yu; Zhao, Wenhui; Hu, Yaosheng; Zhang, Daxin; Chen, Ziyin; Lewis, Elfed

    2016-04-01

    An investigation into a novel in-vivo PMMA (polymethyl methacrylate) fiber-optic dosimeter to monitor the dose of ionizing radiation, both for instantaneous and integrating measurements, for radiotherapy applications is proposed. This fiber sensor is designed as an intracorporal X-ray ionizing sensor to enhance the curative effect of radiotherapy. The fiber-optic dosimeter is made in a PMMA fiber, whose core is micromachined to create a small diameter (0.25 to 0.5 mm) hole at one fiber end. An inorganic scintillating material, terbium-doped gadolinium oxysulfide (Gd2O2S:Tb) is chosen as the sensing material, because it can fluoresce on immediately under exposure of ionizing radiation (X-Rays or electron beam). This sensing material is filled and packaged in the small hole by epoxy resin adhesive. This kind of novel structure dosimeter shows high light coupling efficiency compared with other kind of inorganic scintillation dosimeter. This fiber-optic dosimeter shows good repeatability with a maximum deviation of 0.16%. The testing results of the fiber-optic dosimeter are perfectly proportional to the data of IC with R2 as 0.9999. In addition, the fiber sensor shows excellent isotropic in its radial angular dependence. All the experiments indicate that the fiber-optic dosimeter is properly used for patient in-vivo dosimeter such as brachytherapy applications or intraoperative radiation therapy.

  17. Application of electrets to passive Rn progeny dosimeters

    SciTech Connect

    Khan, A.; Phillips, C.R.

    1985-11-01

    The theoretical and experimental bases are presented for development of a passive electret dosimeter for Rn progeny. The mechanism of aerosol collection is described, and experiments to develop a suitable aerosol collecting element (electret) for a passive Rn progeny dosimeter are reported.

  18. Preliminary investigation and application of a novel deformable PRESAGE® dosimeter

    PubMed Central

    Juang, T; Newton, J; Das, S; Adamovics, J; Oldham, M

    2013-01-01

    Deformable 3D dosimeters have potential applications in validating deformable dose mapping algorithms. This study evaluates a novel deformable PRESAGE® dosimeter and its application toward validating the deformable algorithm employed by VelocityAI. The deformable PRESAGE® dosimeter exhibited a linear dose response with a sensitivity of 0.0032 ΔOD/(Gy/cm). Comparison of an experimental dosimeter irradiated with an MLC pencilbeam checkerboard pattern under lateral compression up to 27% to a non-deformed control dosimeter irradiated with the same pattern verified dose tracking under deformation. CTs of the experimental dosimeter prior to and during compression were exported into VelocityAI and used to map an Eclipse dose distribution calculated on the compressed dosimeter to its original shape. A comparison between the VelocityAI dose distribution and the distribution from the dosimeter showed field displacements up to 7.3 mm and up to a 175% difference in field dimensions. These results highlight the need for validating deformable dose mapping algorithms to ensure patient safety and quality of care. PMID:24454522

  19. Laser readable thermoluminescent radiation dosimeters and methods for producing thereof

    DOEpatents

    Braunlich, Peter F.; Tetzlaff, Wolfgang

    1989-01-01

    Thin layer thermoluminescent radiation dosimeters for use in laser readable dosimetry systems, and methods of fabricating such thin layer dosimeters. The thin layer thermoluminescent radiation dosimeters include a thin substrate made from glass or other inorganic materials capable of withstanding high temperatures and high heating rates. A thin layer of a thermoluminescent phoshphor material is heat bonded to the substrate using an inorganic binder such as glass. The dosimeters can be mounted in frames and cases for ease in handling. Methods of the invention include mixing a suitable phosphor composition and binder, both being in particulate or granular form. The mixture is then deposited onto a substrate such as by using mask printing techniques. The dosimeters are thereafter heated to fuse and bond the binder and phosphor to the substrate.

  20. Investigation into the re-use of PMOS dosimeters

    SciTech Connect

    Kelleher, A.; McDonnell, N.; O'Neill, B.; Lane, W. ); Adams, L. )

    1994-06-01

    Radiation sensitive field effect transistors have applications integrating dosimetry in spacecraft, laboratories and medicine to measure the amount of radiation dose absorbed. However these dosimeters can measure only to a maximum dose which is determined by the type and sensitivity of the RADFET being used. On reaching the maximum radiation dose these dosimeters are usually replaced. The aim of this paper is to investigate the possibility of reusable dosimeters which to-date has not been addressed in the published literature. This study examines the response of dosimeters which were irradiated, annealed back to their original pre-irradiation threshold voltage and then irradiated for a second time. The results of the second irradiation suggest that re-using PMOS dosimeters is a feasible option.

  1. Laser readable thermoluminescent radiation dosimeters and methods for producing thereof

    DOEpatents

    Braunlich, P.F.; Tetzlaff, W.

    1989-04-25

    Thin layer thermoluminescent radiation dosimeters for use in laser readable dosimetry systems, and methods of fabricating such thin layer dosimeters are disclosed. The thin layer thermoluminescent radiation dosimeters include a thin substrate made from glass or other inorganic materials capable of withstanding high temperatures and high heating rates. A thin layer of a thermoluminescent phosphor material is heat bonded to the substrate using an inorganic binder such as glass. The dosimeters can be mounted in frames and cases for ease in handling. Methods of the invention include mixing a suitable phosphor composition and binder, both being in particulate or granular form. The mixture is then deposited onto a substrate such as by using mask printing techniques. The dosimeters are thereafter heated to fuse and bond the binder and phosphor to the substrate. 34 figs.

  2. Investigation of the response characteristics of OSL albedo neutron dosimeters in a 241AmBe reference neutron field

    NASA Astrophysics Data System (ADS)

    Liamsuwan, T.; Wonglee, S.; Channuie, J.; Esoa, J.; Monthonwattana, S.

    2017-06-01

    The objective of this work was to systematically investigate the response characteristics of optically stimulated luminescence Albedo neutron (OSLN) dosimeters to ensure reliable personal dosimetry service provided by Thailand Institute of Nuclear Technology (TINT). Several batches of InLight® OSLN dosimeters were irradiated in a reference neutron field generated by the in-house 241AmBe neutron irradiator. The OSL signals were typically measured 24 hours after irradiation using the InLight® Auto 200 Reader. Based on known values of delivered neutron dose equivalent, the reading correction factor to be used by the reader was evaluated. Subsequently, batch homogeneity, dose linearity, lower limit of detection and fading of the OSLN dosimeters were examined. Batch homogeneity was evaluated to be 0.12 ± 0.05. The neutron dose response exhibited a linear relationship (R2=0.9974) within the detectable neutron dose equivalent range under test (0.4-3 mSv). For this neutron field, the lower limit of detection was between 0.2 and 0.4 mSv. Over different post-irradiation storage times of up to 180 days, the readings fluctuated within ±5%. Personal dosimetry based on the investigated OSLN dosimeter is considered to be reliable under similar neutron exposure conditions, i.e. similar neutron energy spectra and dose equivalent values.

  3. Response of thermoluminescent dosimeters to photons simulated with the Monte Carlo method

    NASA Astrophysics Data System (ADS)

    Moralles, M.; Guimarães, C. C.; Okuno, E.

    2005-06-01

    Personal monitors composed of thermoluminescent dosimeters (TLDs) made of natural fluorite (CaF 2:NaCl) and lithium fluoride (Harshaw TLD-100) were exposed to gamma and X rays of different qualities. The GEANT4 radiation transport Monte Carlo toolkit was employed to calculate the energy depth deposition profile in the TLDs. X-ray spectra of the ISO/4037-1 narrow-spectrum series, with peak voltage (kVp) values in the range 20-300 kV, were obtained by simulating a X-ray Philips MG-450 tube associated with the recommended filters. A realistic photon distribution of a 60Co radiotherapy source was taken from results of Monte Carlo simulations found in the literature. Comparison between simulated and experimental results revealed that the attenuation of emitted light in the readout process of the fluorite dosimeter must be taken into account, while this effect is negligible for lithium fluoride. Differences between results obtained by heating the dosimeter from the irradiated side and from the opposite side allowed the determination of the light attenuation coefficient for CaF 2:NaCl (mass proportion 60:40) as 2.2 mm -1.

  4. Light scattering in optical CT scanning of Presage dosimeters

    NASA Astrophysics Data System (ADS)

    Xu, Y.; Adamovics, J.; Cheeseborough, J. C.; Chao, K. S.; Wuu, C. S.

    2010-11-01

    The intensity of the scattered light from the Presage dosimeters was measured using a Thorlabs PM100D optical power meter (Thorlabs Inc, Newton, NJ) with an optical sensor of 1 mm diameter sensitive area. Five Presage dosimeters were made as cylinders of 15.2 cm, 10 cm, 4 cm diameters and irradiated with 6 MV photons using a Varian Clinac 2100EX. Each dosimeter was put into the scanning tank of an OCTOPUS" optical CT scanner (MGS Research Inc, Madison, CT) filled with a refractive index matching liquid. A laser diode was positioned at one side of the water tank to generate a stationary laser beam of 0.8 mm width. On the other side of the tank, an in-house manufactured positioning system was used to move the optical sensor in the direction perpendicular to the outgoing laser beam from the dosimeters at an increment of 1 mm. The amount of scattered photons was found to be more than 1% of the primary light signal within 2 mm from the laser beam but decreases sharply with increasing off-axis distance. The intensity of the scattered light increases with increasing light attenuations and/or absorptions in the dosimeters. The scattered light at the same off-axis distance was weaker for dosimeters of larger diameters and for larger detector-to-dosimeter distances. Methods for minimizing the effect of the light scattering in different types of optical CT scanners are discussed.

  5. Radiation Measured during ISS-Expedition 13 with Different Dosimeters

    NASA Technical Reports Server (NTRS)

    Zhou, D.; Semones, E.; Gaza, R.; Johnson, S.; Zapp, N.; Lee, K.; George, T.

    2008-01-01

    Radiation in low Earth orbit (LEO) is mainly composed of Galactic Cosmic Rays (GCR), solar energetic particles and particles in SAA (South Atlantic Anomaly). The biological impact of space radiation to astronauts depends strongly on the particles linear energy transfer (LET) and is dominated by high LET radiation. It is important to measure the LET spectrum for the space radiation field and to investigate the influence of radiation on astronauts. At present, the preferred active dosimeters sensitive to all LET are the tissue equivalent proportional counter (TEPC) and silicon detectors in various configurations; the preferred passive dosimeters are thermoluminescence dosimeters (TLDs) and optically stimulated luminescence dosimeters (OSLDs) sensitive to low LET as well as CR-39 plastic nuclear track detectors (PNTDs) sensitive to high LET. The TEPC, CR-39 PNTDs, TLDs and OSLDs were used to investigate the radiation exposure for the ISS mission Expedition 13 (ISS-12S) in LEO. LET spectra and radiation quantities (fluence, absorbed dose, dose equivalent and quality factor) were measured for the space mission with different dosimeters. This paper introduces the operational principles for the dosimeters, describes the method to combine the results measured by TLDs/OSLDs and CR-39 PNTDs, and presents the LET spectra and the radiation quantities measured. Keywords: space radiation; cosmic rays; active and passive dosimeters; LET spectra

  6. SU-E-T-265: Presage Thin Sheet Dosimeter Characterization

    SciTech Connect

    Dumas, M; Rakowski, J

    2014-06-01

    Purpose: To quantify the sensitivity and stability of the Presage dosimeter in sheet form for different concentrations of chemicals and for a diverse range of clinical photon energies. Methods: Presage polymer dosimeters are formulated to investigate and optimize their sensitivity and stability. The dosimeter is composed of clear polyurethane base, leucomalachite green reporting dye, and bromoform radical initiator in 1mm thick sheets. The chemicals are well mixed together, cast in an aluminum mold, and left to cure at 60 psi for a minimum of 2 days. Dosimeter response will be characterized at multiple energies including Co-60, 6 MV, 15 MV, 50 kVp, and 250 kVp. The dosimeters are read by an Epson 10000 XL scanner at 800 dpi, 2{sup 16} bit depth. Red component images are analyzed with ImageJ. Results: Analysis of optical density verse dose for Co-60 energies indicates that the bromoform containing Presage was able to quantify dose from 0 to 300 Gy, with saturation beyond 300 Gy. Initial results show two regions of linear response, 0–100 Gy and 150–300 Gy. The 150–300 Gy region has a sensitivity of 0.0024 net OD/Gy. Further results on other energies are still in progress. Conclusions: This work shows the potential for use of thin sheets of Presage dosimeter as a dosimeter capable of being analyzed with a flatbed scanner.

  7. SU-E-T-749: Thorough Calibration of MOSFET Dosimeters

    SciTech Connect

    Plenkovich, D; Thomas, J

    2015-06-15

    Purpose: To improve the accuracy of the MOSFET calibration procedure by performing the measurement several times and calculating the average value of the calibration factor for various photon and electron energies. Methods: The output of three photon and six electron beams of Varian Trilogy linear accelerator SN 5878 was calibrated. Five reinforced standard sensitivity MOSFET dosimeters were placed in the calibration jig and connected to the Reader Module. As the backscatter material was used 7 cm of Virtual Water. The MOSFET dosimeters were covered with 1.5 cm thick bolus for the regular and SRS 6 MV beams, 3 cm bolus for 15 MV beam, 1.5 cm bolus for 6 MeV electron beam, and 2 cm bolus for the electron energies of 9, 12, 15, 18, and 22 MeV. The dosimeters were exposed to 100 MU, and the calibration factor was determined using the mobileMOSFET software. To improve the accuracy of calibration, this procedure was repeated ten times and the calibration factors were averaged. Results: As the number of calibrations was increasing the variability of calibration factors of different dosimeters was decreasing. After ten calibrations, the calibration factors for all five dosimeters were within 1% of one another for all energies, except 6 MV SRS photons and 6 MeV electrons, for which the variability was 2%. Conclusions: The described process results in calibration factors which are almost independent of modality or energy. Once calibrated, the dosimeters may be used for in-vivo dosimetry or for daily verification of the beam output. Measurement of the radiation dose under bolus and scatter to the eye are examples of frequent use of calibrated MOSFET dosimeters. The calibration factor determined for full build-up is used under these circumstances. To the best of our knowledge, such thorough procedure for calibrating MOSFET dosimeters has not been reported previously. Best Medical Canada provided MOSFET dosimeters for this project.

  8. Personality.

    PubMed

    Funder, D C

    2001-01-01

    Personality psychology is as active today as at any point in its history. The classic psychoanalytic and trait paradigms are active areas of research, the behaviorist paradigm has evolved into a new social-cognitive paradigm, and the humanistic paradigm is a basis of current work on cross-cultural psychology. Biology and evolutionary theory have also attained the status of new paradigms for personality. Three challenges for the next generation of research are to integrate these disparate approaches to personality (particularly the trait and social-cognitive paradigms), to remedy the imbalance in the person-situation-behavior triad by conceptualizing the basic properties of situations and behaviors, and to add to personality psychology's thin inventory of basic facts concerning the relations between personality and behavior.

  9. Calibration system for albedo neutron dosimeters

    SciTech Connect

    Rothermich, N.E.

    1981-01-01

    Albedo neutron dosimeters have proven to be effective as a method of measuring the dose from neutron exposures that other types of neutron detectors cannot measure. Results of research conducted to calibrate an albedo neutron dosemeter are presented. The calibration procedure consisted of exposing the TLD chips to a 46 curie /sup 238/PuBe source at known distances, dose rates and exposure periods. The response of the TLD's is related to the dose rate measured with a dose rate meter to obtain the calibration factor. This calibration factor is then related to the ratio of the counting rates determined by 9-inch and 3-inch Bonner spheres (also called remmeters) and a calibration curve was determined. 17 references, 10 figures, 3 tables.

  10. p-MOSFET total dose dosimeter

    NASA Technical Reports Server (NTRS)

    Buehler, Martin G. (Inventor); Blaes, Brent R. (Inventor)

    1994-01-01

    A p-MOSFET total dose dosimeter where the gate voltage is proportional to the incident radiation dose. It is configured in an n-WELL of a p-BODY substrate. It is operated in the saturation region which is ensured by connecting the gate to the drain. The n-well is connected to zero bias. Current flow from source to drain, rather than from peripheral leakage, is ensured by configuring the device as an edgeless MOSFET where the source completely surrounds the drain. The drain junction is the only junction not connected to zero bias. The MOSFET is connected as part of the feedback loop of an operational amplifier. The operational amplifier holds the drain current fixed at a level which minimizes temperature dependence and also fixes the drain voltage. The sensitivity to radiation is made maximum by operating the MOSFET in the OFF state during radiation soak.

  11. Guidelines for the calibration of personnel dosimeters

    SciTech Connect

    Roberson, P.L.; Holbrook, K.L.

    1984-01-01

    This guide describes minimum acceptable performance levels for personnel dosimetry systems used at Department of Energy (DOE) facilities. The goal is to improve both the quality of radiological calibrations and the methods of comparing reported occupational doses between DOE facilities. Reference calibration techniques are defined. A standard for evaluation of personnel dosimetry systems and recommended design parameters for personnel dosimeters are also included. Approximate intervals for the radiation energies for which these guidelines are appropriate are 15 keV to 2 MeV for photons; above 0.3 MeV for beta particles; and 1 keV to 2 MeV for neutrons. An analysis of ANSI N13.11 was completed using performance evaluations of selected personnel dosimetry systems in use at DOE facilities. The results of this analysis are incorporated in the guidelines.

  12. A new dosimeter formulation for deformable 3D dose verification

    NASA Astrophysics Data System (ADS)

    Høye, E. M.; Skyt, P. S.; Yates, E. S.; Muren, L. P.; Petersen, J. B. B.; Balling, P.

    2015-01-01

    We present the characteristics of a new silicone-based radiochromic dosimeter containing the leuco-malachite green (LMG) dye. The dose response as well as the dose-rate and photon-energy dependence of the dosimeter were characterized. To optimise the dose response, different concentrations of the chemical components were investigated. The dose response was found to decrease exponentially as a function of time after irradiation. A cylindrical dosimeter was produced and irradiated with a volumetric modulated arc therapy plan; the standard deviation between measured and calculated dose was 5% of the total dose.

  13. Production of element correction factors for thermoluminescent dosimeters

    SciTech Connect

    Plato, P.; Miklos, J.

    1985-11-01

    Approximately 80 processors of personal dosimetry in the United States use thermoluminescent dosimeters (TLDs). Recent demands that dosimetry processors be able to measure radiation doses to within +/- 50% of the correct value have focused attention on the reproducibility of the TL elements within each TLD. The phosphors for these TLDs are manufactured by three companies. A dosimetry processor faces three options concerning the quality of the TL elements purchased; trust the supplier's quality control program, screen new TL elements and discard those that are extremely bad, or use element correction factors (ECFs). The first option results in dosimetry processors failing the +/- 50% accuracy requirement due to excessive variability among the TL elements. The second option still permits large precision errors that come close to the +/- 50% accuracy requirement. This paper advocates the third option and presents a 10-step procedure to produce ECFs. The procedure ensures that the ECFs represent only variations among the TL elements and not variations caused by stability problems with the TLD reader. Following is an example of ECF production for 3000 TLDs.

  14. Personalization.

    ERIC Educational Resources Information Center

    Shore, Rebecca Martin

    1996-01-01

    Describes how a typical high school in Huntington Beach, California, curbed disruptive student behavior by personalizing the school experience for "problem" students. Through mostly volunteer efforts, an adopt-a-kid program was initiated that matched kids' learning styles to adults' personality styles and resulted in fewer suspensions…

  15. Personalization.

    ERIC Educational Resources Information Center

    Shore, Rebecca Martin

    1996-01-01

    Describes how a typical high school in Huntington Beach, California, curbed disruptive student behavior by personalizing the school experience for "problem" students. Through mostly volunteer efforts, an adopt-a-kid program was initiated that matched kids' learning styles to adults' personality styles and resulted in fewer suspensions…

  16. Antioxidant effect of green tea on polymer gel dosimeter

    NASA Astrophysics Data System (ADS)

    Samuel, E. J. J.; Sathiyaraj, P.; Deena, T.; Kumar, D. S.

    2015-01-01

    Extract from Green Tea (GTE) acts as an antioxidant in acrylamide based polymer gel dosimeter. In this work, PAGAT gel was used for investigation of antioxidant effect of GTE.PAGAT was called PAGTEG (Polyacrylamide green tea extract gel dosimeter) after adding GTE. Free radicals in water cause pre polymerization of polymer gel before irradiation. Polyphenols from GTE are highly effective to absorb the free radicals in water. THPC is used as an antioxidant in polymer gel dosimeter but here we were replaced it by GTE and investigated its effect by spectrophotometer. GTE added PAGAT samples response was lower compared to THPC added sample. To increase the sensitivity of the PAGTEG, sugar was added. This study confirmed that THPC was a good antioxidant for polymer gel dosimeter. However, GTE also can be used as an antioxidant in polymer gel if use less quantity (GTE) and add sugar as sensitivity enhancer.

  17. Method and apparatus for reading free falling dosimeter punchcodes

    DOEpatents

    Langsted, James M.

    1992-12-22

    A punchcode reader is provided for reading data encoded in a punchcode hole array on a dosimeter. The dosimeter falls through a passage in the reader containing photosensor detectors disposed along the passage which provide output signals to a microprocessor. The signals are processed to determine the orientation of the dosimeter in the reader, the location and state of punchcode holes in a two row array thereby decoding the encoded data. Multiple rate of fall calculations are made, and if appropriate matching of the punchcode array is not obtained in three tries, an error signal is outputted to the operator. The punchcode reader also provides for storage of data from multiple dosimeters passed through the reader, and for the output of decoded data to an external display or a computer for further processing.

  18. Method and apparatus for reading free falling dosimeter punchcodes

    DOEpatents

    Langsted, J.M.

    1992-12-22

    A punchcode reader is provided for reading data encoded in a punchcode hole array on a dosimeter. The dosimeter falls through a passage in the reader containing photosensor detectors disposed along the passage which provide output signals to a microprocessor. The signals are processed to determine the orientation of the dosimeter in the reader, the location and state of punchcode holes in a two row array thereby decoding the encoded data. Multiple rate of fall calculations are made, and if appropriate matching of the punchcode array is not obtained in three tries, an error signal is output to the operator. The punchcode reader also provides for storage of data from multiple dosimeters passed through the reader, and for the output of decoded data to an external display or a computer for further processing. 8 figs.

  19. Investigating potential physicochemical errors in polymer gel dosimeters

    NASA Astrophysics Data System (ADS)

    Sedaghat, Mahbod; Bujold, Rachel; Lepage, Martin

    2011-09-01

    Measurement errors in polymer gel dosimetry can originate either during irradiation or scanning. One concern related to the exothermic nature of polymerization reaction was that the heat released in polymer gel dosimeters during irradiation modifies their dose response. In this paper, the effect of heat released from the exothermal polymerization reaction on the dose response of a number of dosimeters was studied. In addition, we investigated whether heat-generated geometric distortion existed in newly proposed gel dosimeters that contain highly thermoresponsive polymers. Our results suggest that despite a significant internal temperature increase in some gel compositions, their dose responses are not affected when oxygen is well expelled mechanically from the gel mixture. We also report on significant pre-irradiation instability in some recently developed polymer gel dosimeters but that geometric distortions were not observed. Data obtained by a set of small calibration vials are compared to those obtained from larger phantoms, and potential physicochemical causes of deviations between them are identified.

  20. Surface-enhanced Raman scattering (SERS) dosimeter and probe

    DOEpatents

    Vo-Dinh, Tuan

    1995-01-01

    A dosimeter and probe for measuring exposure to chemical and biological compounds is disclosed. The dosimeter or probe includes a collector which may be analyzed by surface-enhanced Raman spectroscopy. The collector comprises a surface-enhanced Raman scattering-active material having a coating applied thereto to improve the adsorption properties of the collector. The collector may also be used in automated sequential devises, in probe array devices.

  1. Radiation measured during ISS-Expedition 13 with different dosimeters

    NASA Astrophysics Data System (ADS)

    Zhou, Dazhuang; Semones, Edward; Gaza, Ramona; Johnson, Steve; Zapp, Neal; Lee, Kerry; George, Tamra

    Radiation measured during ISS-Expedition 13 with different dosimeters D. Zhou1,2,*, E. Semones1, R. Gaza1,2, S. Johnson1, N. Zapp1, K. Lee1, T. George1 1Johnson Space Center - NASA, 2101 Nasa Parkway, Houston 77058, USA 2Universities Space Research Association, 3600 Bay Area Blvd, Houston 77058, USA *Corresponding author. E-mail address: dazhuang.zhou-1@nasa.gov (D. Zhou). Abstract Radiation in low Earth orbit (LEO) is mainly composed of Galactic Cosmic Rays (GCR), solar energetic particles and particles in SAA (South Atlantic Anomaly). The biological impact of space radiation to astronauts depends strongly on the particles' linear energy transfer (LET) and is dominated by high LET radiation. It is important to measure the LET spectrum for the space radiation field and to investigate the influence of radiation on astronauts. At present, the preferred active dosimeters sensitive to all LET are the tissue equivalent proportional counter (TEPC) and silicon detectors in various configurations; the preferred passive dosimeters are thermoluminescence dosimeters (TLDs) and optically stimulated luminescence dosimeters (OSLDs) sensitive to low LET as well as CR-39 plastic nuclear track detectors (PNTDs) sensitive to high LET. The TEPC, CR-39 PNTDs, TLDs and OSLDs were used to investigate the radiation exposure for the ISS mission Expedition 13 (ISS-12S) in LEO. LET spectra and radiation quantities (fluence, absorbed dose, dose equivalent and quality factor) were measured for the space mission with different dosimeters. This paper introduces the operational principles for the dosimeters, describes the method to combine the results measured by TLDs/OSLDs and CR-39 PNTDs, and presents the LET spectra and the radiation quantities measured. Keywords: space radiation; cosmic rays; active and passive dosimeters; LET spectra

  2. Surface-enhanced Raman scattering (SERS) dosimeter and probe

    DOEpatents

    Vo-Dinh, T.

    1995-03-21

    A dosimeter and probe for measuring exposure to chemical and biological compounds is disclosed. The dosimeter or probe includes a collector which may be analyzed by surface-enhanced Raman spectroscopy. The collector comprises a surface-enhanced Raman scattering-active material having a coating applied thereto to improve the adsorption properties of the collector. The collector may also be used in automated sequential devices, in probe array devices. 10 figures.

  3. Methods and means of checking thermoluminescent and radiophotoluminescent dosimeters

    SciTech Connect

    Fominykh, V.I.; Oborin, A.V.; Sebekin, A.P.; Uryaev, I.A.

    1987-06-01

    The authors discuss methods of checking thermoluminescent and radiophotoluminescent dosimeters which are used often in monitoring radiation safety in various areas including nuclear power stations. When the dosimeters are checked in the fields of standard beta-ray sources, it is recommended that the standard absorbed-dose or equivalent-dose measures for beta radiation should be sources of /sup 90/Sr + /sup 90/Y, /sup 204/Tl, and /sup 147/Pm. Various safety guidelines are discussed.

  4. Radiation measured for ISS-Expedition 12 with different dosimeters

    NASA Astrophysics Data System (ADS)

    Zhou, D.; Semones, E.; Gaza, R.; Johnson, S.; Zapp, N.; Weyland, M.

    2007-10-01

    Radiation in low Earth orbit (LEO) is mainly from Galactic Cosmic Rays (GCR), solar energetic particles and particles in South Atlantic Anomaly (SAA). These particles' radiation impact to astronauts depends strongly on the particles' linear energy transfer (LET) and is dominated by high LET radiation. It is important to investigate the LET spectrum for the radiation field and the influence of radiation on astronauts. At present, the best active dosimeters used for all LET are the tissue equivalent proportional counter (TEPC) and silicon detectors; the best passive dosimeters are thermoluminescence dosimeters (TLDs) or optically stimulated luminescence dosimeters (OSLDs) for low LET and CR-39 plastic nuclear track detectors (PNTDs) for high LET. TEPC, CR-39 PNTDs, TLDs and OSLDs were used to investigate the radiation for space mission Expedition 12 (ISS-11S) in LEO. LET spectra and radiation quantities (fluence, absorbed dose, dose equivalent and quality factor) were measured for the mission with these different dosimeters. This paper introduces the operation principles for these dosimeters, describes the method to combine the results measured by CR-39 PNTDs and TLDs/OSLDs, presents the experimental LET spectra and the radiation quantities.

  5. Experimental evaluation of a MOSFET dosimeter for proton dose measurements.

    PubMed

    Kohno, Ryosuke; Nishio, Teiji; Miyagishi, Tomoko; Hirano, Eriko; Hotta, Kenji; Kawashima, Mitsuhiko; Ogino, Takashi

    2006-12-07

    The metal oxide semiconductor field-effect transistor (MOSFET) dosimeter has been widely studied for use as a dosimeter for patient dose verification. The major advantage of this detector is its size, which acts as a point dosimeter, and also its ease of use. The commercially available TN502RD MOSFET dosimeter manufactured by Thomson and Nielsen has never been used for proton dosimetry. Therefore we used the MOSFET dosimeter for the first time in proton dose measurements. In this study, the MOSFET dosimeter was irradiated with 190 MeV therapeutic proton beams. We experimentally evaluated dose reproducibility, linearity, fading effect, beam intensity dependence and angular dependence for the proton beam. Furthermore, the Bragg curve and spread-out Bragg peak were also measured and the linear-energy transfer (LET) dependence of the MOSFET response was investigated. Many characteristics of the MOSFET response for proton beams were the same as those for photon beams reported in previous papers. However, the angular MOSFET responses at 45, 90, 135, 225, 270 and 315 degrees for proton beams were over-responses of about 15%, and moreover the MOSFET response depended strongly on the LET of the proton beam. This study showed that the angular dependence and LET dependence of the MOSFET response must be considered very carefully for quantitative proton dose evaluations.

  6. Response of the Hanford Combination Neutron Dosimeter in plutonium environments

    SciTech Connect

    Endres, A.W.; Brackenbush, L.W.; Baumgartner, W.V.

    1996-02-01

    This report documents response characteristics and the development of dose algorithms for the Hanford Combination Neutron Dosimeter (HCNO) implemented on January 1, 1995. The HCND was accredited under the U.S. Department of Energy (DOE) Laboratory Accreditation Program (DOELAP) during 1994. The HCND employs two neutron dose components consisting of (1) an albedo thermoluminescent dosimeter (TLD), and (2) a track-etch dosimeter (TED). Response characteristics of these two dosimeter components were measured under the low-scatter conditions of the Hanford 318 Building Calibration Laboratory, and under the high-scatter conditions in the workplace at the Plutonium Finishing Plant (PFP). The majority of personnel neutron dose at Hanford (currently and historically) occurs at the PFP. National Institute of Standards and Technology (NIST) traceable sources were used to characterize dosimeter response in the laboratory. At the PFP, neutron spectra and dose-measuring instruments, including a multisphere spectrometer, tissue equivalent proportional counters, and specially calibrated rem meters, were used to determine the neutron dose under several configurations from three different plutonium sources: (1) plutonium tetrafluoride, (2) plutonium metal, and (3) plutonium oxide. In addition, measurements were performed at many selected work locations. The HCNDs were included in all measurements. Comparison of dosimeter- and instrument-measured dose equivalents provided the data necessary to develop HCND dose algorithms and to assess the accuracy of estimated neutron dose under actual work conditions.

  7. Potential High Resolution Dosimeters For MRT

    SciTech Connect

    Braeuer-Krisch, E.; Brochard, T.; Prezado, Y.; Bravin, A.; Berkvens, P.; Rosenfeld, A.; Lerch, M.; Petasecca, M.; Akselrod, M.; Sykora, J.; Bartz, J.; Ptaszkiewicz, M.; Olko, P.; Berg, A.; Wieland, M.; Doran, S.; Kamlowski, A.; Cellere, G.

    2010-07-23

    /s, micron resolution and a dose range over several orders of magnitude. This paper will give an overview of all dosimeters tested in the past at the ESRF with their advantages and drawbacks. These detectors comprise: Ionization chambers, Alanine Dosimeters, MOSFET detectors, Gafchromic registered films, Radiochromic polymers, TLDs, Polymer gels, Fluorescent Nuclear Track Detectors (Al{sub 2}O{sub 3}:C, Mg single crystal detectors), OSL detectors and Floating Gate-based dosimetry system. The aim of such a comparison shall help with a decision on which of these approaches is most suitable for high resolution dose measurements in MRT. The principle of these detectors will be presented including a comparison for some dosimeters exposed with the same irradiation geometry, namely a 1x1 cm{sup 5} field size with microbeam exposures at the surface, 0.1 cm and 1 cm in depth of a PMMA phantom. For these test exposures, the most relevant irradiation parameters for future clinical trials have been chosen: 50 micron FWHM and 400 micron c-t-c distance. The experimental data are compared with Monte Carlo calculations.

  8. Potential High Resolution Dosimeters For MRT

    NASA Astrophysics Data System (ADS)

    Bräuer-Krisch, E.; Rosenfeld, A.; Lerch, M.; Petasecca, M.; Akselrod, M.; Sykora, J.; Bartz, J.; Ptaszkiewicz, M.; Olko, P.; Berg, A.; Wieland, M.; Doran, S.; Brochard, T.; Kamlowski, A.; Cellere, G.; Paccagnella, A.; Siegbahn, E. A.; Prezado, Y.; Martinez-Rovira, I.; Bravin, A.; Dusseau, L.; Berkvens, P.

    2010-07-01

    resolution and a dose range over several orders of magnitude. This paper will give an overview of all dosimeters tested in the past at the ESRF with their advantages and drawbacks. These detectors comprise: Ionization chambers, Alanine Dosimeters, MOSFET detectors, Gafchromic® films, Radiochromic polymers, TLDs, Polymer gels, Fluorescent Nuclear Track Detectors (Al2O3:C, Mg single crystal detectors), OSL detectors and Floating Gate-based dosimetry system. The aim of such a comparison shall help with a decision on which of these approaches is most suitable for high resolution dose measurements in MRT. The principle of these detectors will be presented including a comparison for some dosimeters exposed with the same irradiation geometry, namely a 1×1 cm5 field size with microbeam exposures at the surface, 0.1 cm and 1 cm in depth of a PMMA phantom. For these test exposures, the most relevant irradiation parameters for future clinical trials have been chosen: 50 micron FWHM and 400 micron c-t-c distance. The experimental data are compared with Monte Carlo calculations.

  9. PDT dose dosimeter for pleural photodynamic therapy

    NASA Astrophysics Data System (ADS)

    Kim, Michele M.; Darafsheh, Arash; Ahmad, Mahmoud; Finlay, Jarod C.; Zhu, Timothy C.

    2016-03-01

    PDT dose is the product of the photosensitizer concentration and the light fluence in the target tissue. For improved dosimetry during plural photodynamic therapy (PDT), a PDT dose dosimeter was developed to measure both the light fluence and the photosensitizer concentration simultaneously in the same treatment location. Light fluence and spectral data were rigorously compared to other methods of measurement (e.g. photodiode, multi-fiber spectroscopy contact probe) to assess the accuracy of the measurements as well as their uncertainty. Photosensitizer concentration was obtained by measuring the fluorescence of the sensitizer excited by the treatment light. Fluence rate based on the intensity of the laser spectrum was compared to the data obtained by direct measurement of fluence rate by a fiber-coupled photodiode. Phantom studies were done to obtain an optical property correction for the fluorescence signal. Measurements were performed in patients treated Photofrin for different locations in the pleural cavity. Multiple sites were measured to investigate the heterogeneity of the cavity and to provide cross-validation via relative dosimetry. This novel method will allow for accurate real-time determination of delivered PDT dose and improved PDT dosimetry.

  10. A liquid fluorescence dosimeter for proton dosimetry

    NASA Astrophysics Data System (ADS)

    Nadrowitz, Roger; Coray, Adolf; Boehringer, Terence; Dunst, Jürgen; Rades, Dirk

    2012-03-01

    The pyromellitic acid (benzene-1,2,4,5-tetracrboxylic acid) dosimeter is a liquid, nearly tissue equivalent detector (the density of the solution is 1.000 56 g cm-3). This acid fluoresces after exposure to proton radiation, if excited with light. The detector was exposed to proton doses of 1.0-10.0 Gy (energies: 138 and 160 MeV). The correlation between fluorescence intensity and delivered energy dose is one to one and linear, whereby the deviation from the linear behavior for all measured values is less than 1%. Variations of the dose rate between 2.4 and 6.0 Gy s-1 had no influence on the correlation between dose and fluorescence. The quenching of the pyromellitic acid detector amounts to about 22% for 138 MeV protons in the Bragg peak. For the period of 1-26 days after exposure, an increase in fluorescence intensity of the exposed solutions (5.0 Gy) was noticed, which corresponds to a daily data drift averaging 0.91% if the solution is stored in the dark at 4 °C. Non-exposed solutions showed no change of the control value.

  11. A liquid fluorescence dosimeter for proton dosimetry.

    PubMed

    Nadrowitz, Roger; Coray, Adolf; Boehringer, Terence; Dunst, Jürgen; Rades, Dirk

    2012-03-07

    The pyromellitic acid (benzene-1,2,4,5-tetracrboxylic acid) dosimeter is a liquid, nearly tissue equivalent detector (the density of the solution is 1.000 56 g cm⁻³). This acid fluoresces after exposure to proton radiation, if excited with light. The detector was exposed to proton doses of 1.0-10.0 Gy (energies: 138 and 160 MeV). The correlation between fluorescence intensity and delivered energy dose is one to one and linear, whereby the deviation from the linear behavior for all measured values is less than 1%. Variations of the dose rate between 2.4 and 6.0 Gy s⁻¹ had no influence on the correlation between dose and fluorescence. The quenching of the pyromellitic acid detector amounts to about 22% for 138 MeV protons in the Bragg peak. For the period of 1-26 days after exposure, an increase in fluorescence intensity of the exposed solutions (5.0 Gy) was noticed, which corresponds to a daily data drift averaging 0.91% if the solution is stored in the dark at 4 °C. Non-exposed solutions showed no change of the control value.

  12. Mixed-radiation discrimination using thermoluminescent dosimeters

    NASA Astrophysics Data System (ADS)

    Skopec, Marlene

    This work has developed, analyzed, and tested methods to discriminate among different types of radiation exposures using the glow curves of thermoluminescent dosimeters (TLDs). Thermoluminescent materials, Harshaw LiF:Mg,Ti (TLD-100) and CaF2:Tm (TLD-300), were exposed to pure proton, pure photon (x-ray and gamma), and mixed fields to examine and use differences in the thermoluminescent (TL) glow curve shapes for the purpose of radiation type discrimination. The effect of radiation type exposure order on thermoluminescent glow curve shape and the principle of superposition of glow curves were evaluated. Using computerized glow curve deconvolution (CGCD), no significant differences in glow curve shape or magnitude were found. Results demonstrated that the superposition of pure field glow curves is a valid method of simulating mixed field glow curves (i.e., the principle of superposition holds). Two robust and novel techniques for radiation type discrimination were developed: vector representation (VR) and principal component analysis (PCA). In VR, vectors were constructed from glow curve points and classified based on the vector inner product with a unit vector and vector magnitude. In PCA, variations in the glow curves due to radiation type are classified according to one principal component. The two methods were tested for accuracy using leave-one-out validation (LOOV) with classification based on the Mahalanobis distance. Overall, both techniques performed equally well, with over 92% accurate three category classification using the high temperature peak of TLD-100 and nearly 100% correct classification in TLD-300.

  13. Preliminary evaluation of implantable MOSFET radiation dosimeters.

    PubMed

    Beddar, A S; Salehpour, M; Briere, T M; Hamidian, H; Gillin, M T

    2005-01-07

    In this paper, we report on measurements performed on a new prototype implantable radiation detector that uses metal-oxide semiconductor field effect transistors (MOSFETs) designed for in vivo dosimetry. The dosimeters, which are encapsulated in hermetically sealed glass cylinders, are used in an unbiased mode during irradiation, unlike other MOSFET detectors previously used in radiotherapy applications. They are powered by radio frequency telemetry for dose measurements, obviating the need for a power supply within each capsule. We have studied the dosimetric characteristics of these MOSFET detectors in vitro under irradiation from a 60Co source. The detectors show a dose reproducibility generally within 5% or better, with the main sources of error being temperature fluctuations occurring between the pre- and post-irradiation measurements as well as detector orientation. A better temperature-controlled environment leads to a reproducibility within 2%. Our preliminary in vitro results show clearly that true non-invasive in vivo dosimetry measurements are feasible and can be performed remotely using telemetric technology.

  14. Developing an integrating biological dosimeter for spaceflight

    NASA Astrophysics Data System (ADS)

    Zhao, Yang; Jones, Martin; Baillie, David; Rose, Ann

    2007-09-01

    Exposure to harmful radiation is one of the major threats to human beings in outer-space; however, the biological consequences of long term exposure are not well understood. It would be useful to have a means of measuring the effect of space radiation on a living organism during space flights. We conducted a pilot project as part of the International Caenorhabditis elegans Experiment First Flight (ICE-First) project on the International Space Station (ISS). Using a mutational capture system, the eT1 balancer, along with other mutation detection systems, we analyzed the mutational effects of the 11 day mission. Upon recovery, classical genetic approaches and comparative genomic hybridization (CGH) microarrays were used to isolate and characterize mutant strains. Although in this short period of time, as expected no increase in mutational background was observed, we were able to demonstrate the potential of this system for longer-term measurement of biological damage. A sixmonth exposure experiment using the same system is currently in progress on the ISS. The relative simplicity and robustness of this model system demonstrate its potential for use as a biological dosimeter.

  15. PDT Dose Dosimeter for Pleural Photodynamic Therapy

    PubMed Central

    Kim, Michele M.; Darafsheh, Arash; Ahmad, Mahmoud; Finlay, Jarod C.; Zhu, Timothy C.

    2016-01-01

    PDT dose is the product of the photosensitizer concentration and the light fluence in the target tissue. For improved dosimetry during plural photodynamic therapy (PDT), a PDT dose dosimeter was developed to measure both the light fluence and the photosensitizer concentration simultaneously in the same treatment location. Light fluence and spectral data were rigorously compared to other methods of measurement (e.g. photodiode, multi-fiber spectroscopy contact probe) to assess the accuracy of the measurements as well as their uncertainty. Photosensitizer concentration was obtained by measuring the fluorescence of the sensitizer excited by the treatment light. Fluence rate based on the intensity of the laser spectrum was compared to the data obtained by direct measurement of fluence rate by a fiber-coupled photodiode. Phantom studies were done to obtain an optical property correction for the fluorescence signal. Measurements were performed in patients treated Photofrin for different locations in the pleural cavity. Multiple sites were measured to investigate the heterogeneity of the cavity and to provide cross-validation via relative dosimetry. This novel method will allow for accurate real-time determination of delivered PDT dose and improved PDT dosimetry. PMID:27053825

  16. Worms in space? A model biological dosimeter.

    PubMed

    Zhao, Yang; Johnsen, Robert; Baillie, David; Rose, Ann

    2005-06-01

    Although it is well known that radiation causes mutational damage, little is known about the biological effects of long-term exposure to radiation in space. Exposure to radiation can result in serious heritable defects in experimental animals, and in humans, susceptibility to cancer, radiation-sickness, and death at high dosages. It is possible to do ground controlled studies of different types of radiation on experimental animals and to physically measure radiation on the space station or on space probes. However, the actual biological affects of long-term exposure to the full range of space radiation have not been studied, and little information is available about the biological consequences of solar flares. Biological systems are not simply passive recording instruments. They respond differently under different conditions, and thus it is important to be able to collect data from a living animal. There are technical difficulties that restrict the placement of an experimental organism in a space environment for long periods of time, in a manner that allows for the recovery of genetic data. Use of the self-fertilizing hermaphroditic nematode, Caenorhabditis elegans offers potential for the design of a biological dosimeter. In this paper, we describe the advantages of this model system and review the literature of C. elegans in space.

  17. Description and evaluation of the Hanford personnel dosimeter program from 1944 through 1989. [Contain Glossary

    SciTech Connect

    Wilson, R.H.; Fix, J.J.; Baumgartner, W.V.; Nichols, L.L.

    1990-09-01

    This report describes the evolution of personnel dosimeter technology at Hanford since the inception of Hanford operations in 1944. Each of the personnel dosimeter systems used by people working or visiting Hanford is described. In addition, the procedures used to calibrate and calculate dose for each of the dosimeter systems are described. The accuracy of the recorded dose, primarily whole body deep dose, for the different dosimeter systems is evaluated. The evaluation is based on an extensive review of historical literature, as well as a 1989 intercomparison study of all film dosimeters and performance testing of the thermoluminescent dosimeter, also conducted during 1989. 73 refs., 40 figs., 41 tabs.

  18. Thermal neutron dosimeter by synthetic single crystal diamond devices.

    PubMed

    Almaviva, S; Marinelli, Marco; Milani, E; Prestopino, G; Tucciarone, A; Verona, C; Verona-Rinati, G; Angelone, M; Pillon, M

    2009-07-01

    We report on a new solid state dosimeter based on chemical vapor deposition (CVD) single crystal diamond fabricated at Roma "Tor Vergata" University laboratories. The dosimeter has been specifically designed for direct neutron dose measurements in boron neutron capture therapy (BNCT). The response to thermal neutrons of the proposed diamond dosimeter is directly due to (10)B and, therefore, the dosimeter response is directly proportional to the boron absorbed doses in BNCT. Two single crystal diamond detectors are fabricated in a p-type/intrinsic/metal configuration and are sandwiched together with a boron containing layer in between the metallic contacts (see Fig.1). Neutron irradiations were performed at the Frascati Neutron Generator (FNG) using the 2.5 MeV neutrons produced through the D(d,n)(3)He fusion reaction. Thermal neutrons were then produced by slowing down the 2.5 MeV neutrons using a cylindrical polymethylmethacrylate (PMMA) moderator. The diamond dosimeter was placed in the center of the moderator. The products of (10)B(n,alpha)Li nuclear reaction were collected simultaneously giving rise to a single peak. Stable performance, high reproducibility, high efficiency and good linearity were observed.

  19. Water-equivalent fiber radiation dosimeter with two scintillating materials

    PubMed Central

    Qin, Zhuang; Hu, Yaosheng; Ma, Yu; Lin, Wei; Luo, Xianping; Zhao, Wenhui; Sun, Weimin; Zhang, Daxin; Chen, Ziyin; Wang, Boran; Lewis, Elfed

    2016-01-01

    An inorganic scintillating material plastic optical fiber (POF) dosimeter for measuring ionizing radiation during radiotherapy applications is reported. It is necessary that an ideal dosimeter exhibits many desirable qualities, including water equivalence, energy independence, reproducibility, dose linearity. There has been much recent research concerning inorganic dosimeters. However, little reference has been made to date of the depth-dose characteristics of dosimeter materials. In the case of inorganic scintillating materials, they are predominantly non water-equivalent, with their effective atomic weight (Zeff) being typically much greater than that of water. This has been a barrier in preventing inorganic scintillating material dosimeter from being used in actual clinical applications. In this paper, we propose a parallel-paired fiber light guide structure to solve this problem. Two different inorganic scintillating materials are embedded separately in the parallel-paired fiber. It is shown that the information of water depth and absorbed dose at the point of measurement can be extracted by utilizing their different depth-dose properties. PMID:28018715

  20. An assessment of radiotherapy dosimeters based on CVD grown diamond

    NASA Astrophysics Data System (ADS)

    Ramkumar, S.; Buttar, C. M.; Conway, J.; Whitehead, A. J.; Sussman, R. S.; Hill, G.; Walker, S.

    2001-03-01

    Diamond is potentially a very suitable material for use as a dosimeter for radiotherapy. Its radiation hardness, the near tissue equivalence and chemical inertness are some of the characteristics of diamond, which make it well suited for its application as a dosimeter. Recent advances in the synthesis of diamond by chemical vapour deposition (CVD) technology have resulted in the improvement in the quality of material and increased its suitability for radiotherapy applications. We report in this paper, the response of prototype dosimeters based on two different types (CVD1 and CVD2) of CVD diamond to X-rays. The diamond devices were assessed for sensitivity, dependence of response on dose and dose rate, and compared with a Scanditronix silicon photon diode and a PTW natural diamond dosimeter. The diamond devices of CVD1 type showed an initial increase in response with dose, which saturates after ≈6 Gy. The diamond devices of CVD2 type had a response at low fields (<1162.8 V/cm) that was linear with dose and dose rate. At high fields (>1162.8 V/cm), the CVD2-type devices showed polarisation and dose-rate dependence. The sensitivity of the CVD diamond devices varied between 82 and 1300 nC/Gy depending upon the sample type and the applied voltage. The sensitivity of CVD diamond devices was significantly higher than that of natural diamond and silicon dosimeters. The results suggest that CVD diamond devices can be fabricated for successful use in radiotherapy applications.

  1. Portable magnetic field dosimeter with data acquisition capabilities

    NASA Astrophysics Data System (ADS)

    Fujita, T. Y.; Tenforde, T. S.

    1982-03-01

    Design concepts, engineering specifications, and performance test results are presented for a compact magnetic field dosimeter that is suitable for monitoring personnel exposures to steady-state and time-varying magnetic fields. The battery-operated dosimeter contains thin-film Hall sensors that record the magnetic induction (B) along three orthogonal axes. The Hall generators are operated in a pulsed mode, and the time rate of change of the magnetic induction (dB/dt) is determined for values of B recorded during consecutive sampling intervals (typically 75 ms). The pulsed mode operation also serves to reduce battery consumption. The dosimeter contains a programmable microprocessor-based logic circuit and 4096 12-bit words of permanent and random-access memory. Stored parameters include: (1) average values of B and dB/dt during a preset time interval (typically 5 min); (2) peak values of B and dB/dt during the preset interval; and (3) the number of times that specified threshold levels for these parameters are exceeded. An audible alarm is activated when B or dB/dt exceeds a specified threshold level. Sensitivity factors and threshold levels can be loaded into the dosimeter from a bench-mounted programmable calculator, which is also used at the end of each workday to record and process data stored in the dosimeter's random-access memory.

  2. PNNL Results from 2010 CALIBAN Criticality Accident Dosimeter Intercomparison Exercise

    SciTech Connect

    Hill, Robin L.; Conrady, Matthew M.

    2011-10-28

    This document reports the results of the Hanford personnel nuclear accident dosimeter (PNAD) and fixed nuclear accident dosimeter (FNAD) during a criticality accident dosimeter intercomparison exercise at the CEA Valduc Center on September 20-23, 2010. Pacific Northwest National Laboratory (PNNL) participated in a criticality accident dosimeter intercomparison exercise at the Commissariat a Energie Atomique (CEA) Valduc Center near Dijon, France on September 20-23, 2010. The intercomparison exercise was funded by the U.S. Department of Energy, Nuclear Criticality Safety Program, with Lawrence Livermore National Laboratory as the lead Laboratory. PNNL was one of six invited DOE Laboratory participants. The other participating Laboratories were: Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Savannah River Site (SRS), the Y-12 National Security Complex at Oak Ridge, and Sandia National Laboratory (SNL). The goals of PNNL's participation in the intercomparison exercise were to test and validate the procedures and algorithm currently used for the Hanford personnel nuclear accident dosimeters (PNADs) on the metallic reactor, CALIBAN, to test exposures to PNADs from the side and from behind a phantom, and to test PNADs that were taken from a historical batch of Hanford PNADs that had varying degrees of degradation of the bare indium foil. Similar testing of the PNADs was done on the Valduc SILENE test reactor in 2009 (Hill and Conrady, 2010). The CALIBAN results are reported here.

  3. Radiation measured with different dosimeters during STS-121 space mission

    NASA Astrophysics Data System (ADS)

    Zhou, D.; Semones, E.; Gaza, R.; Johnson, S.; Zapp, N.; Weyland, M.; Rutledge, R.; Lin, T.

    2009-02-01

    Radiation impact to astronauts depends on the particles' linear energy transfer (LET) and is dominated by high LET radiation. Radiation risk experienced by astronauts can be determined with the radiation LET spectrum measured and the risk response function obtained from radiobiology. Systematical measurement of the space radiation is an important part for the research on the impact of radiation to astronauts and to make the radiation ALARA (as low as reasonably achievable). For NASA space missions at low Earth orbit (LEO), the active dosimeter used for all LET is the tissue equivalent proportional counter (TEPC) and the passive dosimeters used for the astronauts and for the monitored areas are the combination of CR-39 plastic nuclear track detectors (PNTDs) for high LET and thermoluminescence dosimeters (TLDs) and optically stimulated luminescence dosimeter (OSLDs) for low LET. TEPC, CR-39 PNTDs and TLDs/OSLDs were used to measure the radiation during STS-121 space mission. LET spectra and radiation quantities were obtained with active and passive dosimeters. This paper will introduce the physical principles for TEPC and CR-39 detectors, the LET spectrum method for radiation measurement using CR-39 detectors and TEPC, and will present and compare the radiation LET spectra and quantities measured with TEPC, CR-39 PNTDs and TLDs/OSLDs.

  4. Water-equivalent fiber radiation dosimeter with two scintillating materials.

    PubMed

    Qin, Zhuang; Hu, Yaosheng; Ma, Yu; Lin, Wei; Luo, Xianping; Zhao, Wenhui; Sun, Weimin; Zhang, Daxin; Chen, Ziyin; Wang, Boran; Lewis, Elfed

    2016-12-01

    An inorganic scintillating material plastic optical fiber (POF) dosimeter for measuring ionizing radiation during radiotherapy applications is reported. It is necessary that an ideal dosimeter exhibits many desirable qualities, including water equivalence, energy independence, reproducibility, dose linearity. There has been much recent research concerning inorganic dosimeters. However, little reference has been made to date of the depth-dose characteristics of dosimeter materials. In the case of inorganic scintillating materials, they are predominantly non water-equivalent, with their effective atomic weight (Zeff) being typically much greater than that of water. This has been a barrier in preventing inorganic scintillating material dosimeter from being used in actual clinical applications. In this paper, we propose a parallel-paired fiber light guide structure to solve this problem. Two different inorganic scintillating materials are embedded separately in the parallel-paired fiber. It is shown that the information of water depth and absorbed dose at the point of measurement can be extracted by utilizing their different depth-dose properties.

  5. Performance testing of extremity dosimeters against a draft standard

    SciTech Connect

    Harty, R.; Reece, W.D.; Hooker, C.D.; McDonald, J.C.

    1990-09-01

    The assurance of worker radiation safety is directly related to the performance of personnel dosimetry. The US Department of Energy (DOE) has long recognized this critical relationship and has addressed this issue by instituting the DOE Laboratory Accreditation Program (DOELAP) which strives to improve the quality of personnel dosimetry through performance testing, dosimetry calibration, intercomparisons, evaluations and accreditations. One area of personnel dosimetry that has not been specifically addressed by DOELAP is extremity dosimeter testing. This task was directed at assessing the problems of implementing extremity dosimeter performance testing. A series of performance tests were made based on a draft standard written by the Health Physics Society Standards Committee (HPSSC) using extremity dosimeters currently in use at DOE and DOE contractor facilities. The results of this study indicate the need to incorporate performance testing of extremity dosimetry systems into DOELAP. Based on the results of this study, recommendations are made for improvements to the draft standard. 20 refs., 6 figs., 3 tabs.

  6. Commissioning and implementation of an implantable dosimeter for radiation therapy.

    PubMed

    Buzurovic, Ivan; Showalter, Timothy N; Studenski, Matthew T; Den, Robert B; Dicker, Adam P; Cao, Junsheng; Xiao, Ying; Yu, Yan; Harrison, Amy

    2013-03-04

    In this article we describe commissioning and implementation procedures for the Dose Verification System (DVS) with permanently implanted in vivo wireless, telemetric radiation dosimeters for absolute dose measurements. The dosimeter uses a semiconductor device called a metal-oxide semiconductor field-effect transistor (MOSFET) to measure radiation dose. A MOSFET is a transistor that is generally used for amplifying or switching electronic signals. The implantable dosimeter was implemented with the goal of verifying the dose delivered to radiation therapy patients. For the purpose of acceptance testing, commissioning, and clinical implementation and to evaluate characteristics of the dosimeter, the following tests were performed: 1) temperature dependence, 2) reproducibility,3) field size dependence, 4) postirradiation signal drift, 5) dependence on average dose rate, 6) linearity test, 7) angular dependence (different gantry angle position), 8) angular dependence (different DVS angle position), 9) dose rate dependence,10) irradiation depth dependence, 11) effect of cone-beam exposure to the dosimeter, and 12) multiple reading effect. The dosimeter is not currently calibrated for use in the kV range; nonetheless, the effect of the cone-beam procedure on the MOSFET dosimeter was investigated. Phantom studies were performed in both air and water using an Elekta Synergy S Beam-Modulator linear accelerator. Commissioning and clinical implementation for prostate cancer patients receiving external-beam radiation therapy were performed in compliance with the general recommendations given for in vivo dosimetry devices. The reproducibility test in water at human body temperature (37°C) showed a 1.4% absolute difference, with a standard deviation of 5.72 cGy (i.e., SD = 2.9%). The constancy test shows that the average readings at room temperature were 3% lower compared to the readings at human body temperature, with a SD = 2%. Measurements were not dependent upon field size

  7. Monitoring of environmental UV radiation by biological dosimeters.

    PubMed

    Ronto, G; Berces, A; Grof, P; Fekete, A; Kerekgyarto, T; Gaspar, S; Stick, C

    2000-01-01

    As a consequence of the stratospheric ozone layer depletion biological systems can be damaged due to increased UV-B radiation. The aim of biological dosimetry is to establish a quantitative basis for the risk assessment of the biosphere. DNA is the most important target molecule of biological systems having special sensitivity against short wavelength components of the environmental radiation. Biological dosimeters are usually simple organisms, or components of them, modeling the cellular DNA. Phage T7 and polycrystalline uracil biological dosimeters have been developed and used in our laboratory for monitoring the environmental radiation in different radiation conditions (from the polar to equatorial regions). Comparisons with Robertson-Berger (RB) meter data, as well as with model calculation data weighted by the corresponding spectral sensitivities of the dosimeters are presented. Suggestion is given how to determine the trend of the increase in the biological risk due to ozone depletion. c2001 COSPAR Published by Elsevier Science Ltd. All rights reserved.

  8. Development and evaluation of polycrystalline cadmium telluride dosimeters for accurate quality assurance in radiation therapy

    NASA Astrophysics Data System (ADS)

    Oh, K.; Han, M.; Kim, K.; Heo, Y.; Moon, C.; Park, S.; Nam, S.

    2016-02-01

    For quality assurance in radiation therapy, several types of dosimeters are used such as ionization chambers, radiographic films, thermo-luminescent dosimeter (TLD), and semiconductor dosimeters. Among them, semiconductor dosimeters are particularly useful for in vivo dosimeters or high dose gradient area such as the penumbra region because they are more sensitive and smaller in size compared to typical dosimeters. In this study, we developed and evaluated Cadmium Telluride (CdTe) dosimeters, one of the most promising semiconductor dosimeters due to their high quantum efficiency and charge collection efficiency. Such CdTe dosimeters include single crystal form and polycrystalline form depending upon the fabrication process. Both types of CdTe dosimeters are commercially available, but only the polycrystalline form is suitable for radiation dosimeters, since it is less affected by volumetric effect and energy dependence. To develop and evaluate polycrystalline CdTe dosimeters, polycrystalline CdTe films were prepared by thermal evaporation. After that, CdTeO3 layer, thin oxide layer, was deposited on top of the CdTe film by RF sputtering to improve charge carrier transport properties and to reduce leakage current. Also, the CdTeO3 layer which acts as a passivation layer help the dosimeter to reduce their sensitivity changes with repeated use due to radiation damage. Finally, the top and bottom electrodes, In/Ti and Pt, were used to have Schottky contact. Subsequently, the electrical properties under high energy photon beams from linear accelerator (LINAC), such as response coincidence, dose linearity, dose rate dependence, reproducibility, and percentage depth dose, were measured to evaluate polycrystalline CdTe dosimeters. In addition, we compared the experimental data of the dosimeter fabricated in this study with those of the silicon diode dosimeter and Thimble ionization chamber which widely used in routine dosimetry system and dose measurements for radiation

  9. Imaging of Absorbed Dose in Radiotherapy by a Polymer Gel Dosimeter

    NASA Astrophysics Data System (ADS)

    Vanossi, E.; Gambarini, G.; Carrara, M.; Mariani, M.; Negri, A.

    2008-06-01

    Optical imaging of polymer gel dosimeters in form of layers was investigated to enquire their reliability for in-phantom dose measurements in photon or thermal neutron fields. The obtained dose measurements were compared with those achieved by means of Fricke gel dosimeters. Reliability of Fricke gel dosimeters was confirmed, whereas it has been shown that a conspicuous improvement of the adopted polymer gel dosimeters is necessary.

  10. Implanted Dosimeters Identify Radiation Overdoses During IMRT for Prostate Cancer

    SciTech Connect

    Den, Robert B.; Nowak, Kamila; Buzurovic, Ivan; Cao Junsheng; Harrison, Amy S.; Lawrence, Yaacov R.; Dicker, Adam P.; Showalter, Timothy N.

    2012-07-01

    Purpose: Image-guided dose-escalated radiotherapy is the standard of care for the treatment of prostate cancer. Although many published methods are available that account for prostate motion during delivery, evidence demonstrating that the planned dose is actually delivered on a daily basis is lacking. We report our initial clinical experience using implantable dosimeters to quantify and adjust the dose received during intensity-modulated radiotherapy (IMRT). Methods and Materials: A total of 20 patients undergoing IMRT with cone-beam computed tomography (CT) image guidance for prostate cancer had the dose verification system with radiopaque metal-oxide-semiconductor field effect transistor dosimeters implanted before treatment planning. All patients underwent planning with CT simulation in the supine position with custom immobilization, and the implanted dosimeters were located in the IMRT plans. The predicted dose for each dosimeter was defined and compared with the wireless readings before and after each treatment session. Investigations by physicians and medical physicists were initiated for two or more discrepancies >6% for any five consecutive fractions or for any discrepancy {>=}10%. Results: Using implanted in vivo dosimeters, dose measurements consistently >6% greater than the predicted values were observed during treatment for 3 of 20 prostate cancer patients who received IMRT with daily image guidance. A review of the daily cone-beam CT images revealed acceptable alignment of the prostate target volumes and implanted dosimeters but identified significant anatomic changes within the treated region. Repeat CT simulation and RT planning was performed, with resolution of the dose discrepancies in all 3 cases with the adoption of a new IMRT plan. Conclusions: Our report illustrates the potential effect of implanted in vivo dosimetry for prostate IMRT and emphasizes the importance of careful planning and delivery with attention to systematic shifts or anatomic

  11. A floating gate MOSFET dosimeter requiring no external bias supply

    SciTech Connect

    Tarr, N.G.; Mackay, G.F.; Thomson, I.; Shortt, K.

    1998-06-01

    MOSFET dosimeters incorporating an electrically floating polysilicon gate have been fabricated in a commercial CMOS technology. Charge is placed on the floating gate by tunneling from a small overlapping injector gate. Subsequent irradiation partially discharges the floating gate, producing a change in threshold voltage which can be used to infer the absorbed dose. No external power source is required during this sensing period. Sensitivities up to 70 mVGy{sup {minus}1} (0.7 mV/rad) have been obtained for temperature-compensated matched-pair dosimeters under {sup 60}Co gamma irradiation.

  12. Measurement of a PAGAT gel dosimeter by ultrasound computed tomography

    NASA Astrophysics Data System (ADS)

    Khoei, S.; Trapp, J. V.; Langton, C. M.

    2013-06-01

    In this work we used a 3D quantitative CT ultrasound imaging system to characterise polymer gel dosimeters. The system comprised of two identical 5 MHz 128 element phased-array ultrasound transducers co-axially aligned and submerged in water as a coupling agent. Rotational and translational movement of the gel dosimeter sample between the transducers were performed using a robotic arm. Ultrasound signals were generated and received using an Olympus Omniscan unit. Dose sensitivity of attenuation and time of flight ultrasonic parameters were assessed using this system.

  13. Basic radiological characteristics of a non-scattering gel dosimeter for 3D dosimetry

    NASA Astrophysics Data System (ADS)

    Chang, Kyung Hwan; Ji, Yunseo; Lee, Suk; Kim, Kwang Hyeon; Yang, Dae Sik; Lee, Jung Ae; Park, Young Je; Yoon, Won Sup; Kim, Chul Yong; Cao, Yuanjie; Cho, Samju

    2016-12-01

    We used a spectrophotometer to compare the dosimetric properties of two non-scattering (radiochromic) gel dosimeters: a non-scattering gel dosimeter developed in-house and a PRESAGE™ gel dosimeter. We evaluated the dosimetric characteristics, including spectral absorption, dose linearity, reproducibility, and dose rate dependency of the two gel dosimeters. The non-scattering gel and the PRESAGE™ gel dosimeters showed peak sensitivity at wavelengths of 600 nm and 630 nm, respectively. Over a range of doses the best dose linearities of the non-scattering and the PRESAGE™ gel dosimeters resulted in R2 values of 0.99 at wavelengths of 600 nm and 630 nm, respectively. The reproducibility and dose-rate dependence of each of the two gel dosimeters were within the range of ±3 %. Our results revealed that the peak sensitivities of the two radiochromic gel dosimeters were significantly different; the in-house non-scattering gel dosimeter demonstrated peak sensitivity at a wavelength of 600 nm while the PRESAGE™ gel dosimeter had peak sensitivity at a wavelength of 630 nm. We confirmed that for 3D gel dosimetry, the in-house non-scattering gel dosimeter had a more stable dose response compared with a commercial non-scattering gel dosimeter.

  14. A simple convenient biological dosimeter for monitoring solar UV-B radiation

    SciTech Connect

    Wang, T.C. )

    1991-05-31

    The use of dry Bacillus subtilis spores as a biological dosimeter for the monitoring of solar UV-B (290-330 nm) radiation was described. Our field tests had supported the utility of this dosimeter as a reproducible and reliable sunlight dosimeter.

  15. Latex Rubber Gloves as a Sampling Dosimeter Using a Novel Surrogate Sampling Device.

    PubMed

    Sankaran, Gayatri; Lopez, Terry; Ries, Steve; Ross, John; Vega, Helen; Eastmond, David A; Krieger, Robert I

    2015-01-01

    Pesticide exposure during harvesting of crops occurs primarily to the workers' hands. When harvesters wear latex rubber gloves for personal safety and hygiene harvesting reasons, gloves accumulate pesticide residues. Hence, characterization of the gloves' properties may be useful for pesticide exposure assessments. Controlled field studies were conducted using latex rubber gloves to define the factors that influence the transfer of pesticides to the glove and that would affect their use as a residue monitoring device. A novel sampling device called the Brinkman Contact Transfer Unit (BCTU) was constructed to study the glove characteristics and residue transfer and accumulation under controlled conditions on turf. The effectiveness of latex rubber gloves as sampling dosimeters was evaluated by measuring the transferable pesticide residues as a function of time. The validation of latex rubber gloves as a residue sampling dosimeter was performed by comparing pesticide transfer and dissipation from the gloves, with the turf transferable residues sampled using the validated California (CA) Roller, a standard measure of residue transfer. The observed correlation (Pearson's correlation coefficient R(2)) between the two methods was .84 for malathion and .96 for fenpropathrin, indicating that the BCTU is a useful, reliable surrogate tool for studying available residue transfer to latex rubber gloves under experimental conditions. Perhaps more importantly, these data demonstrate that latex gloves worn by workers may be useful quantifiable matrices for measuring pesticide exposure.

  16. Deconnable self-reading pocket dosimeter containment with self-contained light

    DOEpatents

    Stevens, Robyn L.; Arnold, Greg N.; McBride, Ryan G.

    1996-01-01

    A container for a self-reading pocket dosimeter includes a transparent tube for receiving the self-reading pocket dosimeter, a light source mounted at one end of the transparent tube, and an eyepiece mounted on an opposite end of the transparent tube for viewing a read-out of the self-reading pocket dosimeter. The container may further include an activation device for selectively supplying power to the light source. The container both protects the dosimeter from being contaminated and provides a light source for viewing the dosimeter.

  17. Two methods for examining angular response of personnel dosimeters

    SciTech Connect

    Plato, P.; Leib, R.; Miklos, J.

    1988-06-01

    The American National Standard ANSI N13.11-1983 is used to test the accuracy (bias plus precision) of dosimetry processors as part of the dosimetry accreditation program of the National Voluntary Laboratory Accreditation Program (NVLAP). Section 3.8 of the ANSI N13.11-1983 standard requires that a study of the angular response of a dosimeter be carried out once, although no pass/fail criterion is given for angular response. The NVLAP accreditation program excluded Section 3.8, and thus no angular response data have been generated in an organized fashion. The objective of this project is to examine the feasibility of two alternative methods to test the angular response of personnel dosimeters. The first alternative involves static irradiations with the dosimeters at fixed angles to a radiation source. The second alternative involves dynamic irradiations with the dosimeters mounted on a rotating phantom. A Panasonic UD-802 personnel dosimetry system** was used to generate data to examine both alternatives. The results lead to two major conclusions. Firstly, Section 3.8 of the ANSI N13.11-1983 standard should be amended to require a pass/fail test for angular response. Secondly, a comparison between angular response data generated with a fixed or a rotating phantom shows that the rotating phantom is the more cost-effective method.

  18. Thin thermoluminescent dosimeter and method of making same

    DOEpatents

    Simons, Gale G.; DeBey, Timothy M.

    1987-01-01

    An improved thermoluminescent ionizing radiation dosimeter of solid, extremely thin construction for more accurate low energy beta dosimetry is provided, along with a method of fabricating the dosimeter. In preferred forms, the dosimeter is a composite including a backing support (which may be tissue equivalent) and a self-sustaining body of solid thermoluminescent material such as LiF having a thickness of less than about 0.25 millimeters and a volume of at least about 0.0125 mm.sup.3. In preferred fabrication procedures, an initially thick (e.g., 0.89 millimeters) TLD body is wet sanded using 600 grit or less sandpaper to a thickness of less than about 0.25 millimeters, followed by adhesively attaching the sanded body to an appropriate backing. The sanding procedure permits routine production of extremely thin (about 0.05 millimeters) TLD bodies, and moreover serves to significantly reduce non-radiation-induced thermoluminescence. The composite dosimeters are rugged in use and can be subjected to annealing temperatures for increased accuracy.

  19. Activation of Dosimeters Used in qa of Medical Linear Accelerators

    NASA Astrophysics Data System (ADS)

    Polaczek-Grelik, Kinga; Nowacka, Magdalena; Raczkowski, Maciej

    2017-09-01

    This paper presents the first results of a project intended to investigate γ-radiation activity induced in dosimeters used in clinical practice during routine quality assurance of high-energy photon beams emitted by electron linear accelerators. Two aspects of the activation via photonuclear reactions (X, n) of therapeutic beam and subsequent capture of secondary neutrons (n,γ) are under considerations: the influence of activation on intrinsic background of the dosimeters and exposure of dosimetrists who operate this equipment. The activation of several types of ionization chambers as well as the silicon diodes was studied after long-time exposure (10 000 MUs) of the 15 MV photon beam (Elekta Synergy). Photon fluxes obtained from spectra of γ-rays registered by HPGe spectrometer were subsequently converted to equivalent doses using appropriate coefficients. The main contribution to the induced activity comes from the neutron capture process on Al, Mn and Cu, therefore it decays quite fast with the half-lives of the order of 15 minutes. Nevertheless, the activation of chlorine was also observed. The estimated equivalent doses to skin and eye lens were in the range 0.19 - 0.62 μSv/min. However, no influence on intrinsic background signal of all studied dosimeters was observed. The preliminary results indicate that induced radioactivity of dosimeters is strongly influenced by therapeutic beam quality and neutron source strength of particular linac. This dependence will be studied deeper in order to quantify it more precisely.

  20. Improvements in opti-chromic dosimeters for radiation processing

    NASA Astrophysics Data System (ADS)

    Humpherys, K. C.; Kantz, A. D.

    "Opti-Chromic" dosimeters consisting of radiachromic dye in flourinated polymer tubing have been introduced as a dosimetry system in the range from 10 1 to 5 × 10 4 Gy. Batches of "Opti-Chromic" dosimeters have been produced to evaluate performance under large scale industrial conditions. A systematic study was undertaken to determine the effect of various dosimeter parameters on radiation sensitivity, shelf life, and response characteristics at the higher absorbed doses. These parameters were (A) Type of flourinated polymer tubing; (B) Organic solvent used to activate the radiachromic dye; (C) Concentration of radiachromic dye; (D) Additives to provide proper viscosity, color stability, and high-dose response. Prototype batches were produced and experimental dosimeters exposed to a range of absorbed doses and the response measured as a function of shelf life and dose. The results of the study are presented, and an improved formulation recommended for application to Food Processing. Other formulations may be of value in specific requirements of sensitivity or temperature.

  1. Thin thermoluminescent dosimeter and method of making same

    SciTech Connect

    Simons, G.G.; DeBey, T.M.

    1987-01-13

    An improved thermoluminescent ionizing radiation dosimeter of solid, extremely thin construction for more accurate low energy beta dosimetry is provided, along with a method of fabricating the dosimeter. In preferred forms, the dosimeter is a composite including a backing support (which may be tissue equivalent) and a self-sustaining body of solid thermoluminescent material such as LiF having a thickness of less than about 0.25 millimeters and a volume of at least about 0.0125 mm[sup 3]. In preferred fabrication procedures, an initially thick (e.g., 0.89 millimeters) TLD body is wet sanded using 600 grit or less sandpaper to a thickness of less than about 0.25 millimeters, followed by adhesively attaching the sanded body to an appropriate backing. The sanding procedure permits routine production of extremely thin (about 0.05 millimeters) TLD bodies, and moreover serves to significantly reduce non-radiation-induced thermoluminescence. The composite dosimeters are rugged in use and can be subjected to annealing temperatures for increased accuracy. 1 fig.

  2. Validation of an Innovative Satellite-Based UV Dosimeter

    NASA Astrophysics Data System (ADS)

    Morelli, Marco; Masini, Andrea; Simeone, Emilio; Khazova, Marina

    2016-08-01

    We present an innovative satellite-based UV (ultraviolet) radiation dosimeter with a mobile app interface that has been validated by exploiting both ground-based measurements and an in-vivo assessment of the erythemal effects on some volunteers having a controlled exposure to solar radiation.Both validations showed that the satellite-based UV dosimeter has a good accuracy and reliability needed for health-related applications.The app with this satellite-based UV dosimeter also includes other related functionalities such as the provision of safe sun exposure time updated in real-time and end exposure visual/sound alert. This app will be launched on the global market by siHealth Ltd in May 2016 under the name of "HappySun" and available both for Android and for iOS devices (more info on http://www.happysun.co.uk).Extensive R&D activities are on-going for further improvement of the satellite-based UV dosimeter's accuracy.

  3. Hanford Personnel Dosimeter supporting studies FY-1980. [Lead abstract

    SciTech Connect

    Endres, G.W.R.; Cummings, F.M.; Aldrich, J.M.; Thorson, M.R.; Kathren, R.L.

    1981-02-01

    Separate abstracts were prepared for the 10 sections of this report which describe fundamental characteristics of the Hanford multipurpose personnel dosimeter (HMPD). Abstracts were not prepared for Appendix A and Appendix B which deal with calculated standard deviations for 100 mrem mixed field exposures and detailed calculations of standard deviations, respectively. (KRM)

  4. Field test of fiber optic hydrazine dosimeters at Cape Canaveral

    NASA Astrophysics Data System (ADS)

    Klimcak, Charles M.; Chan, Y.; Jaduszliwer, B.

    1999-02-01

    We tested seventy-two hydrazine fuel fiber optic dosimeters for periods up to three months or Cape Canaveral in order to determine the effect of the local environment on its lifetime and sensitivity. The dosimeters were deployed at a diverse group of sites including fuel, oxidizer, and hydrocarbon fuel storage and transfer locations, a salt spray corrosion test facility, a satellite processing area, an estuarine marsh, a paint storage locker, and several indoor locations including chemical laboratory fume hoods and bathrooms. In addition, a group were set aside in a sealed enclosure for control purposes. The dosimeters were retrieved at monthly intervals and exposed to measured doses of hydrazine vapor to determine the effects of the field exposure on their hydrazine response. Our analysis indicated that 90% of the exposed dosimeters were able to sense hydrazine at a dose detectivity of less than 15 ppb-hr, a value that meets the current hydrazine sensing requirement. Consequently, we are planning to deploy a full scale, continuously operating fiber optic system for detecting potential hydrazine leaks during launch operations at Cape Canaveral.

  5. Portable battery-free charger for radiation dosimeters

    DOEpatents

    Manning, Frank W.

    1984-01-01

    This invention is a novel portable charger for dosimeters of the electrometer type. The charger does not require batteries or piezoelectric crystals and is of rugged construction. In a preferred embodiment, the charge includes a housing which carries means for mounting a dosimeter to be charged. The housing also includes contact means for impressing a charging voltage across the mounted dosimeter. Also, the housing carries a trigger for operating a charging system mounted in the housing. The charging system includes a magnetic loop including a permanent magnet for establishing a magnetic field through the loop. A segment of the loop is coupled to the trigger for movement thereby to positions opening and closing the loop. A coil inductively coupled with the loop generates coil-generated voltage pulses when the trigger is operated to open and close the loop. The charging system includes an electrical circuit for impressing voltage pulses from the coil across a capacitor for integrating the pulses and applying the resulting integrated voltage across the above-mentioned contact means for charging the dosimeter.

  6. Feasibility Study on Applying Radiophotoluminescent Glass Dosimeters for CyberKnife SRS Dose Verification

    PubMed Central

    Hsu, Shih-Ming; Hung, Chao-Hsiung; Liao, Yi-Jen; Fu, Hsiao-Mei; Tsai, Jo-Ting

    2017-01-01

    CyberKnife is one of multiple modalities for stereotactic radiosurgery (SRS). Due to the nature of CyberKnife and the characteristics of SRS, dose evaluation of the CyberKnife procedure is critical. A radiophotoluminescent glass dosimeter was used to verify the dose accuracy for the CyberKnife procedure and validate a viable dose verification system for CyberKnife treatment. A radiophotoluminescent glass dosimeter, thermoluminescent dosimeter, and Kodak EDR2 film were used to measure the lateral dose profile and percent depth dose of CyberKnife. A Monte Carlo simulation for dose verification was performed using BEAMnrc to verify the measured results. This study also used a radiophotoluminescent glass dosimeter coupled with an anthropomorphic phantom to evaluate the accuracy of the dose given by CyberKnife. Measurements from the radiophotoluminescent glass dosimeter were compared with the results of a thermoluminescent dosimeter and EDR2 film, and the differences found were less than 5%. The radiophotoluminescent glass dosimeter has some advantages in terms of dose measurements over CyberKnife, such as repeatability, stability, and small effective size. These advantages make radiophotoluminescent glass dosimeters a potential candidate dosimeter for the CyberKnife procedure. This study concludes that radiophotoluminescent glass dosimeters are a promising and reliable dosimeter for CyberKnife dose verification with clinically acceptable accuracy within 5%. PMID:28046056

  7. Feasibility Study on Applying Radiophotoluminescent Glass Dosimeters for CyberKnife SRS Dose Verification.

    PubMed

    Hsu, Shih-Ming; Hung, Chao-Hsiung; Liao, Yi-Jen; Fu, Hsiao-Mei; Tsai, Jo-Ting; Huang, Yung-Hui; Huang, David Y C

    2017-01-01

    CyberKnife is one of multiple modalities for stereotactic radiosurgery (SRS). Due to the nature of CyberKnife and the characteristics of SRS, dose evaluation of the CyberKnife procedure is critical. A radiophotoluminescent glass dosimeter was used to verify the dose accuracy for the CyberKnife procedure and validate a viable dose verification system for CyberKnife treatment. A radiophotoluminescent glass dosimeter, thermoluminescent dosimeter, and Kodak EDR2 film were used to measure the lateral dose profile and percent depth dose of CyberKnife. A Monte Carlo simulation for dose verification was performed using BEAMnrc to verify the measured results. This study also used a radiophotoluminescent glass dosimeter coupled with an anthropomorphic phantom to evaluate the accuracy of the dose given by CyberKnife. Measurements from the radiophotoluminescent glass dosimeter were compared with the results of a thermoluminescent dosimeter and EDR2 film, and the differences found were less than 5%. The radiophotoluminescent glass dosimeter has some advantages in terms of dose measurements over CyberKnife, such as repeatability, stability, and small effective size. These advantages make radiophotoluminescent glass dosimeters a potential candidate dosimeter for the CyberKnife procedure. This study concludes that radiophotoluminescent glass dosimeters are a promising and reliable dosimeter for CyberKnife dose verification with clinically acceptable accuracy within 5%.

  8. a Thermally Desorbable Miniature Passive Dosimeter for Organic Vapors

    NASA Astrophysics Data System (ADS)

    Gonzalez, Jesus Antonio

    A thermally desorbable miniature passive dosimeter (MPD) for organic vapors has been developed in conformity with theoretical and practical aspects of passive dosimeter design. The device was optimized for low sample loadings resulting from short-term and/or low concentration level exposure. This was accomplished by the use of thermal desorption rather than solvent elution, which provided the GC method with significantly higher sensitivity. Laboratory evaluation of this device for factors critical to the performance of passive dosimeters using benzene as the test vapor included: desorption efficiency (97.2%), capacity (1400 ppm-min), sensitivity (7ng/sample or 0.06 ppmv for 15 minutes sampling) accuracy and precision, concentration level, environmental conditions (i.e., air face velocity, relative humidity) and sample stability during short (15 minutes) and long periods of time (15 days). This device has demonstrated that its overall accuracy meets NIOSH and OSHA requirements for a sampling and analytical method for the exposure concentration range of 0.1 to 50 ppm (v/v) and 15 minutes exposures. It was demonstrated that the MPD operates in accordance with theoretically predicted performance and should be adequate for short-term and/or low concentration exposure monitoring of organic vapors in the workplace. In addition a dynamic vapor exposure evaluation system for passive dosimeters have been validated using benzene as the test vapor. The system is capable of generating well defined short-square wave concentration profiles suitable for the evaluation of passive dosimeters for ceiling exposure monitoring.

  9. VALIDATION OF HANFORD PERSONNEL AND EXTREMITY DOSIMETERS IN PLUTONIUM ENVIRONMENTS

    SciTech Connect

    Scherpelz, Robert I.; Fix, John J.; Rathbone, Bruce A.

    2000-02-10

    A study was performed in the Plutonium Finishing Plant to assess the performance of Hanford personnel neutron dosimetry. The study was assessed whole body dosimetry and extremity dosimetry performance. For both parts of the study, the TEPC was used as the principle instrument for characterizing workplace neutron fields. In the whole body study, 12.7-cm-diameter TEPCs were used in ten different locations in the facility. TLD and TED personnel dosimeters were exposed on a water-filled phantom to enable a comparison of TEPC and dosimeter response. In the extremity study, 1.27-cm-diameter TEPCs were exposed inside the fingers of a gloveboxe glove. Extremity dosimeters were wrapped around the TEPCs. The glove was then exposed to six different cans of plutonium, simulating the exposure that a worker's fingers would receive in a glovebox. The comparison of TEPC-measured neutron dose equivalent to TLD-measured gamma dose equivalent provided neutron-to-gamma ratios that can be used to estimate the neutron dose equivalent received by a worker's finger based on the gamma readings of an extremity dosimeter. The study also utilized a Snoopy and detectors based on bubble technology for assessing neutron exposures, providing a comparison of the effectiveness of these instruments for workplace monitoring. The study concludes that the TLD component of the HCND performs adequately overall, with a positive bias of 30%, but exhibits excessive variability in individual results due to instabilities in the algorithm. The TED response was less variable but only 20% of the TEPC reference dose on average because of the low neutron energies involved. The neutron response of the HSD was more variable than the TLD component of the HCND and biased high by a factor of 8 overall due to its calibration to unmoderated 252Cf. The study recommends further work to correct instabilities in the HCND algorithm and to explore the potential shown by the bubble-based dosimeters.

  10. Type testing of the Siemens Plessey electronic personal dosemeter.

    PubMed

    Hirning, C R; Yuen, P S

    1995-07-01

    This paper presents the results of a laboratory assessment of the performance of a new type of personal dosimeter, the Electronic Personal Dosemeter made by Siemens Plessey Controls Limited. Twenty pre-production dosimeters and a reader were purchased by Ontario Hydro for the assessment. Tests were performed on radiological performance, including reproducibility, accuracy, linearity, detection threshold, energy response, angular response, neutron response, and response time. There were also tests on the effects of a variety of environmental factors, such as temperature, humidity, pulsed magnetic and electric fields, low- and high-frequency electromagnetic fields, light exposure, drop impact, vibration, and splashing. Other characteristics that were tested were alarm volume, clip force, and battery life. The test results were compared with the relevant requirements of three standards: an Ontario Hydro standard for personal alarming dosimeters, an International Electrotechnical Commission draft standard for direct reading personal dose monitors, and an International Electrotechnical Commission standard for thermoluminescence dosimetry systems for personal monitoring. In general, the performance of the Electronic Personal Dosemeter was found to be quite acceptable: it met most of the relevant requirements of the three standards. However, the following deficiencies were found: slow response time; sensitivity to high-frequency electromagnetic fields; poor resistance to dropping; and an alarm that was not loud enough. In addition, the response of the electronic personal dosimeter to low-energy beta rays may be too low for some applications. Problems were experienced with the reliability of operation of the pre-production dosimeters used in these tests.

  11. Investigation of thermoluminescence properties of mobile phone screen displays as dosimeters for accidental dosimetry

    NASA Astrophysics Data System (ADS)

    Mrozik, Anna; Marczewska, B.; Bilski, P.; Kłosowski, M.

    2014-11-01

    The rapid assessment of the radiation dose after unexpected exposure is a task of accidental dosimetry. In case of a radiological accident glasses originating from mobile phone screens, placed usually near the human body, could be used as emergency thermoluminescent (TL) personal dosimeters. The time between irradiation and TL readout is crucial and therefore preparation of the mobile phone screens and their readout conditions should be optimized. The influence of the samples etching, bleaching and selection of the optical filters based on measurement of the emission spectrum of irradiated glass samples during heating for different types of mobile phones were the subjects of our investigation. Obtained results showed that glasses extracted from different brands of mobile phones have different dosimetric properties but all of them give a luminescent signal which can be used to calculate the dose.

  12. Modified ferrous ammonium sulfate benzoic acid xyelenol orange (MFBX) and thermoluminescent dosimeters--a comparative study.

    PubMed

    Brindha, S; Rose, J V R; Sathyan, S; Singh I, Rabi Raja; Ravindran, B Paul

    2002-06-07

    Radiation dosimetry deals with the determination of absorbed dose to the medium exposed to ionizing radiation. Chemical dosimetry depends on oxidation or reduction of chemicals by ionizing radiation. A ferrous ammonium sulfate benzoic acid xyelenol orange (FBX) dosimeter based on this principle is being used as a clinical dosimeter at present. Certain modifications were carried out in the preparation and storage of the FBX dosimeter to increase its shelf life. The resulting dosimeter was called a modified FBX (MFBX) dosimeter and has been used in our department for the past few years. An extensive study of the dose, dose rate and energy response of the dosimeter was carried out and compared with a thermoluminescent (LiF7) dosimeter. The results obtained were found to be comparable to the thermoluminescent (LiF7) dosimeter. Hence it was concluded that the MFBX dosimeter could be used for phantom dosimetry, data collection and in vivo measurements. Easier preparation and availability of the reagents are added advantages of using MFBX as a clinical dosimeter in small radiotherapy departments.

  13. The high dose response and functional capability of the DT-702/Pd lithium fluoride thermoluminescent dosimeter.

    PubMed

    Lawlor, Tyler M; Talmadge, Molly D; Murray, Mark M; Nelson, Martin E; Mueller, Andrew C; Romanyukha, Alexander A; Fairchild, Gregory R; Grypp, Matthew D; Williams, Anthony S

    2015-05-01

    The United States Navy monitors the dose its radiation workers receive using the DT-702/PD thermoluminescent dosimeter, which consists of the Harshaw 8840 holder and the four-element Harshaw 8841 card. There were two main objectives of this research. In the first objective, the dosimeters were exposed to 100 Gy using electron and x-ray beams and found to respond approximately 30-40% lower than the delivered dose. No significant effect on the under-response was found when dose rate, radiation type, dosimeter position on the phantom, and dosimeter material were varied or when the card was irradiated while enclosed in its holder. Since the current naval policy is to remove from occupational use any thermoluminescent dosimeter with an accumulated deep dose equivalent of 0.05 Sv or greater, the functionality of the dosimeter was also investigated at deep dose equivalents of 0.05, 0.15, and 0.25 Sv using 60Co and 137Cs sources as the second main objective. All dosimeters were annealed following exposure and then exposed to 5.0 mSv from a 90Sr source. In all cases, the dosimeters responded within 3% of the delivered dose, indicating that the dosimeters remained functional as defined by naval dosimetry requirements. However, the anneal time required to clear the thermoluminescent dosimeter's reading was found to increase approximately as the cube root with the delivered dose.

  14. Fricke Gel Dosimeter Tissue-Equivalence a Monte Carlo Study

    NASA Astrophysics Data System (ADS)

    Valente, M.; Bartesaghi, G.; Gambarini, G.; Brusa, D.; Castellano, G.; Carrara, M.

    2008-06-01

    Gel dosimetry has proved to be a valuable technique for absorbed dose distribution measurements in radiotherapy. FriXy-gel dosimeters consist of Fricke (ferrous sulphate) solution infused with xylenol orange. The solution is incorporated to a gel matrix in order to fix it to a solid structure allowing good spatial resolution and is imaged with a transportable optical system, measuring visible light transmittance before and after irradiation. This paper presents an evaluation of total photon mass attenuation coefficients at energies in the range of 50 keV-10MeV for the radiochromic FriXy gel dosimeter sensitive material. Mass attenuation coefficient estimations have been performed by means of Monte Carlo (PENELOPE) simulations. These calculations have been carried out for the FriXy gel sensitive material as well as for soft tissue (ICRU) and pure liquid water; a comparison of the obtained data shows good agreement between the different materials.

  15. A genipin-gelatin gel dosimeter for radiation processing

    NASA Astrophysics Data System (ADS)

    Davies, J. B.; Bosi, S. G.; Baldock, C.

    2012-08-01

    Genipin, a fruit extract from Gardenia jasminoides Ellis, forms cross-links in solutions of gelatin, to form a blue hydrogel that bleaches quantitatively upon irradiation and the colour change can be measured with a spectrophotometer. With the addition of sulphuric acid this dosimeter is sufficiently sensitive for quality assurance of radiotherapy level dosimetry. Without sulphuric acid the gel has a reduced sensitivity and responds linearly with dose between 100 and 1000 Gy, making it potentially useful as a dosimeter for radiation processing applications such as the phytosanitary irradiation treatment of food. We investigated the dose response characteristics of this new formulation and found that the darker gels are more sensitive to dose and have a reduced uncertainty.

  16. SU-E-I-85: Evaluation of a Solid-State Dosimeter Module for Measuring Nuclear Medicine Radionuclides.

    PubMed

    Wendt, R

    2012-06-01

    A recently introduced solid-state dosimeter module (UDOS001, Teledyne Microelectronic Technologies, Los Angeles, CA) requires only external power (e.g., from two nine-volt batteries in series) and a battery- powered data recorder to assemble a compact, portable dosimeter. This device was developed for radiation detection and monitoring of a wide range of radiation types. It has a nominal minimum energy of 100 keV. The present study sought to determine its suitability for measuring the dose from radionuclides used in nuclear medicine. Three radionuclides (initially 4.77 mCi of F-18, 3.86 mCi of I-131, and 12.4 mCi of Tc-99m) were measured at a distance of one meter and at several different angles of incidence. The most sensitive analog output of the dosimeter was digitized by a battery-powered data logging device (Track-It 5VDC, Monarch Instrument, Amherst NH). These data were transferred from the data logger into a Windows 7 personal computer, formatted as an Excel 2010 spreadsheet and converted from voltage to dose using the manufacturer's nominal calibration factor of 14 urad/19.5 mV step. The dose rate was determined from the slope of a linear fit to the cumulated dose as a function of time. The nominal calibration of the dosimeter gives dose rate measurements that are close to published gamma ray dose rate constants for these radionuclides (0.65 vs. 0.70, 0.25 vs. 0.28, and 0.071 vs. 0.078 mrad/mCi-hr respectively). The angular dependence of the response is greater at 140 keV than at 511 keV, but an acceptance angle of at least 90 degrees has uniform response with all three radionuclides. A better calibration factor would be 0.154 urad/19.5 mV step at these gamma ray energies. This dosimeter can be used to measure the dose from common radionuclides used in nuclear medicine. © 2012 American Association of Physicists in Medicine.

  17. An optical dosimeter for monitoring heavy metal ions in water

    NASA Astrophysics Data System (ADS)

    Mignani, Anna G.; Regan, Fiona; Leamy, D.; Mencaglia, A. A.; Ciaccheri, L.

    2005-05-01

    This work presents an optochemical dosimeter for determining and discriminating nickel, copper, and cobalt ions in water that can be used as an early warning system for water pollution. An inexpensive fiber optic spectrophotometer monitors the sensor's spectral behavior under exposure to water solutions of heavy metal ions in the 1-10 mg/l concentration range. The Principal Component Analysis (PCA) method quantitatively determines the heavy metals and discriminates their type and combination.

  18. Fricke dosimeter gel measurements of the profiles of shielded fields.

    PubMed

    Pirani, Luis F; Moreira, Marcos V; Costa, Jhonatha J L; Oliveira, Lucas N; Caldas, Linda V E; de Almeida, Adelaide

    2013-12-01

    In radiation therapy, the shielding of normal tissue can be made using Cerrobend® blocks or a multileaf collimator. In this work, profiles of shielded fields collimated by Cerrobend blocks were obtained through the Fricke Xylenol Gel (FXG) dosimeter irradiated with 6 MV photon beams. The results show that the FXG system can be used in profile measurements of small fields in radiotherapy. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Method for preparing dosimeter for measuring skin dose

    DOEpatents

    Jones, Donald E.; Parker, DeRay; Boren, Paul R.

    1982-01-01

    A personnel dosimeter includes a plurality of compartments containing thermoluminescent dosimeter phosphors for registering radiation dose absorbed in the wearer's sensitive skin layer and for registering more deeply penetrating radiation. Two of the phosphor compartments communicate with thin windows of different thicknesses to obtain a ratio of shallowly penetrating radiation, e.g. beta. A third phosphor is disposed within a compartment communicating with a window of substantially greater thickness than the windows of the first two compartments for estimating the more deeply penetrating radiation dose. By selecting certain phosphors that are insensitive to neutrons and by loading the holder material with neutron-absorbing elements, energetic neutron dose can be estimated separately from other radiation dose. This invention also involves a method of injection molding of dosimeter holders with thin windows of consistent thickness at the corresponding compartments of different holders. This is achieved through use of a die insert having the thin window of precision thickness in place prior to the injection molding step.

  20. Accelerator room photoneutron and photon background measurements using thermoluminescent dosimeters.

    PubMed

    Anderson, D W; Hwang, C C

    1983-02-01

    Photoneutron dose equivalents and photon doses in the treatment room of a clinical linear accelerator were measured with sets of isotopically enriched LiF thermoluminescent dosimeters and a moderating sphere. Dosimeter neutron calibrations with 252Cf sources were repeated many times during the extended series of measurements because the 6LiF dosimeter sensitivity increased with successive neutron irradiations. Expressed as a fraction of the primary bremsstrahlung beam dose at maximum, the photoneutron background was 2.04 +/- 0.05 mrem/rad (10(-3) Sv/Gy) at 1 m lateral to beam center in the patient midplane at 25 MV. The fraction of this result due to thermal neutrons was found to be only about 2%. The photon background dose was 2.98 +/- 0.04 mrad/rad (10(-3) Gy/Gy). The photoneutron dose equivalent per unit primary dose was found to be nearly independent of the collimator size used but increased by 40% when the bremsstrahlung endpoint energy was increased from 20 to 35 MeV with no change in flattening filters.

  1. Real-time dosimeter targeted to nuclear applications

    NASA Astrophysics Data System (ADS)

    Correia, Alexandre; Rosa, Carla C.; Santos, Pedro M. P.; Falcão, António N.; Lorentz, Katharina

    2014-08-01

    An intrinsic fiber optic dosimeter (FOD) targeted to nuclear applications is presented. The proposed real-time dosimeter provides dose information based on the historic record over time of the effects of ionizing radiation on single- and multimode pure silica fibers, and also on PMMA plastic fibers. The effect of 60Co gamma irradiation on optical links based on silica and plastic fibers were assessed, considering thermal environment effects over a wide range of variation of the operating parameters. Cerenkov radiation and radiation-induced absorption effects were in focus. The corresponding distortion and spectral transmission degradation were evaluated over wide range of the operating parameters. Radiation induced attenuation (RIA) has shown a spectral band dependent behaviour up to 840 Gy dose levels. The performance of different fibers was assessed against the performance of non-irradiated fibers. From the measurements of dose rate and total dose imparted by ionizing radiation in the fibers we verified that fibers with radiation resistance issues showed wavelength-dependent radiation sensitivity increasing with dose rate. Upon evaluation of correlations between the total dose, the induced loss at various dose rates and different wavelengths, it was concluded that intrinsic fiber dosimeters can be used for dose rates in the range 4 - 28 Gy/min., typical of severe radiation environments.

  2. Polymer gel dosimeters with PVA-GA matrix.

    PubMed

    Abtahi, Seyed Mohammad Mahdi; Sadeghi Abandansari, Hamid

    2017-07-27

    Properties of a new polymer gel with cross-linked polyvinyl alcohol as a gelatinous matrix were investigated. The new polymer gel dosimeter was named PVABAT. The irradiation was performed using a calibrated (60)Co beam. The dose responses of the PVABAT formulations were quantified with MRI transverse relaxation rate (R2) measurements. The results show that the PVABAT gel responds linearly to the absorbed dose for doses from 30 up to 45 Gy. The maximal amount of [Formula: see text] of PVABAT polymer gel dosimeter was about 0.19 Gy which was indicated on a better resolution in comparison with previously reported acrylamide-based polymer gel dosimeters formulations. Furthermore, the gel response remains stable in the investigated time (192 h) after the irradiation. The effective atomic number and electron density of the new gel showed a maximum difference of 3.2 and 2% with soft tissue respectively. The melting point also increased significantly for new formulation. Furthermore, the new gel formulation has an elemental tissue equivalency for dosimetry applications involving nuclear reactions.

  3. Dosimeter for measuring skin dose and more deeply penetrating radiation

    DOEpatents

    Jones, Donald E.; Parker, DeRay; Boren, Paul R.

    1981-01-01

    A personnel dosimeter includes a plurality of compartments containing thermoluminescent dosimeter phosphors for registering radiation dose absorbed in the wearer's sensitive skin layer and for registering more deeply penetrating radiation. Two of the phosphor compartments communicate with thin windows of different thicknesses to obtain a ratio of shallowly penetrating radiation, e.g. beta. A third phosphor is disposed within a compartment communicating with a window of substantially greater thickness than the windows of the first two compartments for estimating the more deeply penetrating radiation dose. By selecting certain phosphors that are insensitive to neutrons and by loading the holder material with netruon-absorbing elements, energetic neutron dose can be estimated separately from other radiation dose. This invention also involves a method of injection molding of dosimeter holders with thin windows of consistent thickness at the corresponding compartments of different holders. This is achieved through use of a die insert having the thin window of precision thickness in place prior to the injection molding step.

  4. Investigation of radiological properties and water equivalency of PRESAGE dosimeters

    SciTech Connect

    Gorjiara, Tina; Hill, Robin; Kuncic, Zdenka; Adamovics, John; Bosi, Stephen; Kim, Jung-Ha; Baldock, Clive

    2011-04-15

    Purpose: PRESAGE is a dosimeter made of polyurethane, which is suitable for 3D dosimetry in modern radiation treatment techniques. Since an ideal dosimeter is radiologically water equivalent, the authors investigated water equivalency and the radiological properties of three different PRESAGE formulations that differ primarily in their elemental compositions. Two of the formulations are new and have lower halogen content than the original formulation. Methods: The radiological water equivalence was assessed by comparing the densities, interaction probabilities, and radiation dosimetry properties of the three different PRESAGE formulations to the corresponding values for water. The relative depth doses were calculated using Monte Carlo methods for 50, 100, 200, and 350 kVp and 6 MV x-ray beams. Results: The mass densities of the three PRESAGE formulations varied from 5.3% higher than that of water to as much as 10% higher than that of water for the original formulation. The probability of photoelectric absorption in the three different PRESAGE formulations varied from 2.2 times greater than that of water for the new formulations to 3.5 times greater than that of water for the original formulation. The mass attenuation coefficient for the three formulations is 12%-50% higher than the value for water. These differences occur over an energy range (10-100 keV) in which the photoelectric effect is the dominant interaction. The collision mass stopping powers of the relatively lower halogen-containing PRESAGE formulations also exhibit marginally better water equivalency than the original higher halogen-containing PRESAGE formulation. Furthermore, the depth dose curves for the lower halogen-containing PRESAGE formulations are slightly closer to that of water for a 6 MV beam. In the kilovoltage energy range, the depth dose curves for the lower halogen-containing PRESAGE formulations are in better agreement with water than the original PRESAGE formulation. Conclusions: Based

  5. The Assessment of Effective Dose Equivalent Using Personnel Dosimeters

    NASA Astrophysics Data System (ADS)

    Xu, Xie

    From January 1994, U.S. nuclear plants must develop a technically rigorous approach for determining the effective dose equivalent for their work forces. This dissertation explains concepts associated with effective dose equivalent and describes how to assess effective dose equivalent by using conventional personnel dosimetry measurements. A Monte Carlo computer code, MCNP, was used to calculate photon transport through a model of the human body. Published mathematical phantoms of the human adult male and female were used to simulate irradiation from a variety of external radiation sources in order to calculate organ and tissue doses, as well as effective dose equivalent using weighting factors from ICRP Publication 26. The radiation sources considered were broad parallel photon beams incident on the body from 91 different angles and isotropic point sources located at 234 different locations in contact with or near the body. Monoenergetic photons of 0.08, 0.3, and 1.0 MeV were considered for both sources. Personnel dosimeters were simulated on the surface of the body and exposed to with the same sources. From these data, the influence of dosimeter position on dosimeter response was investigated. Different algorithms for assessing effective dose equivalent from personnel dosimeter responses were proposed and evaluated. The results indicate that the current single-badge approach is satisfactory for most common exposure situations encountered in nuclear plants, but additional conversion factors may be used when more accurate results become desirable. For uncommon exposures involving source situated at the back of the body or source located overhead, the current approach of using multi-badges and assigning the highest dose is overly conservative and unnecessarily expensive. For these uncommon exposures, a new algorithm, based on two dosimeters, one on the front of the body and another one on the back of the body, has been shown to yield conservative assessment of

  6. Functional Evaluation of the DOZA DKG-05D Electronic Dosimeter System

    SciTech Connect

    Piper, Roman K.; Scherpelz, Robert I.

    2009-11-04

    The DOZA DKG-05D electronic personal dosimeter (EPD) was the subject of a limited type-test evaluation in support of Plutonium Production Reactor Agreement (PPRA) Implementation. The primary goal of this evaluation was to provide confidence in the functionality of the dosimeter and identify potential weaknesses in PPRA applications. The tests were based on IEC-61526, recommendations of the International Electrotechnical Commission pertaining to EPDs. All tests were performed in Pacific Northwest National Laboratory’s (PNNL) Radiological Calibrations and Standards Facility in the 318 building. The first testing category was functional considerations. The tests found that the mechanical characteristics of the DKG-05D support usability. However, user controls are not intuitive and straightforward, and the user instructions were unclear and difficult to follow. The unit functioned in a variety of humidity conditions. In high temperature conditions it performed well. However, in cold conditions the display began to fade, which limits its usefulness below about 5 °C. The vendor claims that the unit functions to -20 °C, and it may be correctly recording doses at that low temperature, but the doses cannot be read in real time. Testing found that battery life is generally good, operating for 200 hours on a full charge. This is far more than needed for the intended application. Charging the battery, however, had some pitfalls resulting from two charging modes. The high-current mode would be automatically selected if the battery charge fell below a threshold value when inserted in the charger. Otherwise, a low-current mode would be selected. In some cases a battery needing recharging would not get sufficient current to fully charge in a reasonable time period. There were also problems found in the low-battery indication and there was a possibility for data loss in the low-battery condition. The EPD generally performed well in measuring dose and dose rate. There were some

  7. An investigation into the accuracy of the albedo dosimeter DVGN-01 in measuring personnel irradiation doses in the fields of neutron radiation at nuclear power installations of the joint institute for nuclear research

    NASA Astrophysics Data System (ADS)

    Beskrovnaya, L. G.; Goroshkova, E. A.; Mokrov, Yu. V.

    2010-05-01

    The calculated results of research into the accuracy of an individual albedo dosimeter DVGN-01 as it corresponds to the personal equivalent dose for neutrons H p (10) and to the effective dose for neutrons E eff in the neutron fields at Joint Institute for Nuclear Research Nuclear Power Installations (JNPI) upon different geometries of irradiations are presented. It has been shown that correction coefficients are required for the specific estimation of doses by the dosimeter. These coefficients were calculated using the energy sensitivity curve of the dosimeter and the known neutron spectra at JNPI. By using the correction factors, the uncertainties of both doses will not exceed the limits given to the personnel according to the standards.

  8. Design of Interrogation Protocols for Radiation Dose Measurements Using Optically-Stimulated Luminescent Dosimeters.

    PubMed

    Abraham, Sara A; Kearfott, Kimberlee J; Jawad, Ali H; Boria, Andrew J; Buth, Tobias J; Dawson, Alexander S; Eng, Sheldon C; Frank, Samuel J; Green, Crystal A; Jacobs, Mitchell L; Liu, Kevin; Miklos, Joseph A; Nguyen, Hien; Rafique, Muhammad; Rucinski, Blake D; Smith, Travis; Tan, Yanliang

    2017-03-01

    Optically-stimulated luminescent dosimeters are capable of being interrogated multiple times post-irradiation. Each interrogation removes a fraction of the signal stored within the optically-stimulated luminescent dosimeter. This signal loss must be corrected to avoid systematic errors in estimating the average signal of a series of optically-stimulated luminescent dosimeter interrogations and requires a minimum number of consecutive readings to determine an average signal that is within a desired accuracy of the true signal with a desired statistical confidence. This paper establishes a technical basis for determining the required number of readings for a particular application of these dosimeters when using certain OSL dosimetry systems.

  9. Performance evaluation of diagnostic radiology dosimeters in clinical and calibration x-ray beams.

    PubMed

    Hourdakis, Costantine John; Boziari, Argyro; Manetou, Aggeliki

    2010-05-01

    Diagnostic radiology dosimeters should comply with International Electrotechnical Commission (IEC) 61674 standard in order to perform measurements with sufficient accuracy and reliability. The calibration of a dosimeter is performed under, and pertains to, reference conditions. However, in most cases, dosimeters are used for clinical measurements under non-reference conditions. The performance, in terms of accuracy of dose measurements, of six commercial diagnostic radiology dosimeters was tested at reference calibration and at clinical non-reference conditions. The results showed that all dosimeters being tested exhibited limits of variation within the +/-5% IEC limits. Depending on the detector's physical and operational properties, the dosimeters' energy dependence of response values varied from -4.7% to +4.2%. To address this variation of response, calibration at three radiation qualities (RQR 3, RQR 5, and RQR 9), at least, is recommended. Different irradiation conditions such as air kerma rate, x-ray tube design, x-ray system, and dosimeter operational modes affect the dosimeters' response by less than 3%. A dosimeter that complies with IEC standards and operates according to its specifications could be used at typical clinical irradiation conditions taking into account only corrections for the energy dependence of response. In this case, the error in dose accuracy is expected to be less than 3%.

  10. Scintillating fiber optic dosimeters for breast and prostate brachytherapy

    NASA Astrophysics Data System (ADS)

    Moutinho, L. M.; Castro, I. F.; Freitas, H.; Melo, J.; Silva, P.; Gonçalves, A.; Peralta, L.; Rachinhas, P. J.; Simões, P. C. P. S.; Pinto, S.; Pereira, A.; Santos, J. A. M.; Costa, M.; Veloso, J. F. C. A.

    2017-02-01

    Brachytherapy is a radiotherapy modality where the radioactive material is placed close to the tumor, being a common treatment for skin, breast, gynecological and prostate cancers. These treatments can be of low-dose-rate, using isotopes with mean energy of 30 keV, or high-dose-rate, using isotopes such as 192Ir with a mean energy of 380 keV. Currently these treatments are performed in most cases without in-vivo dosimetry for quality control and quality assurance. We developed a dosimeter using small diameter probes that can be inserted into the patient's body using standard brachytherapy needles. By performing real-time dosimetry in breast and prostate brachytherapy it will be possible to perform real-time dose correction when deviations from the treatment plan are observed. The dosimeter presented in this work was evaluated in-vitro. The studies consisted in the characterization of the dosimeter with 500 μm diameter sensitive probes (with a BCF-12 scintillating optical fiber) using an inhouse made gelatin breast phantom with a volume of 566 cm3. A breast brachytherapy treatment was simulated considering a tumor volume of 27 cm3 and a prescribed absolute dose of 5 Gy. The dose distribution was determined by the Inverse Planning Simulated Annealing (IPSA) optimization algorithm (ELEKTA). The dwell times estimated from the experimental measurements are in agreement with the prescribed dwell times, with relative error below 3%. The measured signal-to-noise ratio (SNR) including the stem-effect contribution is below 3%.

  11. An RF dosimeter for independent SAR measurement in MRI scanners

    SciTech Connect

    Qian, Di; Bottomley, Paul A.; El-Sharkawy, AbdEl-Monem M.; Edelstein, William A.

    2013-12-15

    Purpose: The monitoring and management of radio frequency (RF) exposure is critical for ensuring magnetic resonance imaging (MRI) safety. Commercial MRI scanners can overestimate specific absorption rates (SAR) and improperly restrict clinical MRI scans or the application of new MRI sequences, while underestimation of SAR can lead to tissue heating and thermal injury. Accurate scanner-independent RF dosimetry is essential for measuring actual exposure when SAR is critical for ensuring regulatory compliance and MRI safety, for establishing RF exposure while evaluating interventional leads and devices, and for routine MRI quality assessment by medical physicists. However, at present there are no scanner-independent SAR dosimeters. Methods: An SAR dosimeter with an RF transducer comprises two orthogonal, rectangular copper loops and a spherical MRI phantom. The transducer is placed in the magnet bore and calibrated to approximate the resistive loading of the scanner's whole-body birdcage RF coil for human subjects in Philips, GE and Siemens 3 tesla (3T) MRI scanners. The transducer loop reactances are adjusted to minimize interference with the transmit RF field (B{sub 1}) at the MRI frequency. Power from the RF transducer is sampled with a high dynamic range power monitor and recorded on a computer. The deposited power is calibrated and tested on eight different MRI scanners. Whole-body absorbed power vs weight and body mass index (BMI) is measured directly on 26 subjects. Results: A single linear calibration curve sufficed for RF dosimetry at 127.8 MHz on three different Philips and three GE 3T MRI scanners. An RF dosimeter operating at 123.2 MHz on two Siemens 3T scanners required a separate transducer and a slightly different calibration curve. Measurement accuracy was ∼3%. With the torso landmarked at the xiphoid, human adult whole‑body absorbed power varied approximately linearly with patient weight and BMI. This indicates that whole-body torso SAR is on

  12. An RF dosimeter for independent SAR measurement in MRI scanners

    PubMed Central

    Qian, Di; El-Sharkawy, AbdEl-Monem M.; Bottomley, Paul A.; Edelstein, William A.

    2013-01-01

    Purpose: The monitoring and management of radio frequency (RF) exposure is critical for ensuring magnetic resonance imaging (MRI) safety. Commercial MRI scanners can overestimate specific absorption rates (SAR) and improperly restrict clinical MRI scans or the application of new MRI sequences, while underestimation of SAR can lead to tissue heating and thermal injury. Accurate scanner-independent RF dosimetry is essential for measuring actual exposure when SAR is critical for ensuring regulatory compliance and MRI safety, for establishing RF exposure while evaluating interventional leads and devices, and for routine MRI quality assessment by medical physicists. However, at present there are no scanner-independent SAR dosimeters. Methods: An SAR dosimeter with an RF transducer comprises two orthogonal, rectangular copper loops and a spherical MRI phantom. The transducer is placed in the magnet bore and calibrated to approximate the resistive loading of the scanner's whole-body birdcage RF coil for human subjects in Philips, GE and Siemens 3 tesla (3T) MRI scanners. The transducer loop reactances are adjusted to minimize interference with the transmit RF field (B1) at the MRI frequency. Power from the RF transducer is sampled with a high dynamic range power monitor and recorded on a computer. The deposited power is calibrated and tested on eight different MRI scanners. Whole-body absorbed power vs weight and body mass index (BMI) is measured directly on 26 subjects. Results: A single linear calibration curve sufficed for RF dosimetry at 127.8 MHz on three different Philips and three GE 3T MRI scanners. An RF dosimeter operating at 123.2 MHz on two Siemens 3T scanners required a separate transducer and a slightly different calibration curve. Measurement accuracy was ∼3%. With the torso landmarked at the xiphoid, human adult whole‑body absorbed power varied approximately linearly with patient weight and BMI. This indicates that whole-body torso SAR is on average

  13. DNA as a solar dosimeter in the ocean.

    PubMed

    Regan, J D; Carrier, W L; Gucinski, H; Olla, B L; Yoshida, H; Fujimura, R K; Wicklund, R I

    1992-07-01

    Stratospheric ozone depletion may result in increased solar UV-B radiation to the ocean's upper layers and may cause deleterious effects on marine organisms. The primary UV-B damage induced in biological systems is to DNA. While physical measurements of solar UV-B penetration into the sea have been made, the effective depth and magnitude of actual DNA damage have not been determined. In the experiments reported here, UV-B-induced photoproducts (cyclobutane pyrimidine dimers) have been quantified in DNA molecules exposed to solar UV at the surface and at various depths in clear, tropical marine waters off Lee Stocking Island (23 degrees 45' N, 76 degrees 0.7' W), Exuma Cays, Bahamas. (14C)thymidine-labeled DNA or unlabeled bacteriophage phi X174 DNA was placed in specially designed quartz tubes at various depths for up to five days. Following exposure, DNA samples were removed to the laboratory where UV-B-induced pyrimidine dimers were quantified using a radiochromatographic assay, and bacteriophage DNA inactivation by solar UV-B was assayed by plaque formation in spheroplasts of Escherichia coli. Pyrimidine dimer induction was linear with time but the accumulation of dimers in DNA with time varied greatly with depth. Attenuation of dimer formation with depth of water was exponential. DNA at 3 m depth had only 17% of the pyrimidine dimers found at the surface. Bacteriophage phi X174 DNA, while reduced 96% in plaque-forming ability by a one day exposure to solar UV at the surface of the water, showed no effect on plaque formation after a similar exposure at 3 m. The data collected at the water's surface showed a "surface-enhanced dose" in that DNA damages at the real surface were greater than at the imaginary surface, which was obtained by extrapolating the data at depth to the surface. These results show the sensitivity of both the biochemical (dimers) and biological (phage plaques) DNA dosimeters. DNA dosimeters offer a sensitive, convenient and relatively

  14. An RF dosimeter for independent SAR measurement in MRI scanners

    SciTech Connect

    Qian, Di; Bottomley, Paul A.; El-Sharkawy, AbdEl-Monem M.; Edelstein, William A.

    2013-12-15

    Purpose: The monitoring and management of radio frequency (RF) exposure is critical for ensuring magnetic resonance imaging (MRI) safety. Commercial MRI scanners can overestimate specific absorption rates (SAR) and improperly restrict clinical MRI scans or the application of new MRI sequences, while underestimation of SAR can lead to tissue heating and thermal injury. Accurate scanner-independent RF dosimetry is essential for measuring actual exposure when SAR is critical for ensuring regulatory compliance and MRI safety, for establishing RF exposure while evaluating interventional leads and devices, and for routine MRI quality assessment by medical physicists. However, at present there are no scanner-independent SAR dosimeters. Methods: An SAR dosimeter with an RF transducer comprises two orthogonal, rectangular copper loops and a spherical MRI phantom. The transducer is placed in the magnet bore and calibrated to approximate the resistive loading of the scanner's whole-body birdcage RF coil for human subjects in Philips, GE and Siemens 3 tesla (3T) MRI scanners. The transducer loop reactances are adjusted to minimize interference with the transmit RF field (B{sub 1}) at the MRI frequency. Power from the RF transducer is sampled with a high dynamic range power monitor and recorded on a computer. The deposited power is calibrated and tested on eight different MRI scanners. Whole-body absorbed power vs weight and body mass index (BMI) is measured directly on 26 subjects. Results: A single linear calibration curve sufficed for RF dosimetry at 127.8 MHz on three different Philips and three GE 3T MRI scanners. An RF dosimeter operating at 123.2 MHz on two Siemens 3T scanners required a separate transducer and a slightly different calibration curve. Measurement accuracy was ∼3%. With the torso landmarked at the xiphoid, human adult whole‑body absorbed power varied approximately linearly with patient weight and BMI. This indicates that whole-body torso SAR is on

  15. FBX aqueous chemical dosimeter for measurement of dosimetric parameters.

    PubMed

    Moussous, O; Medjadj, T; Benguerba, M

    2011-02-01

    We investigated the ferrous sulphate-benzoic acid-xylenol orange (FBX) aqueous chemical dosimeter for measurement of dosimetric parameters such as the output factor, backscatter factor and lateral beam profiles for different square fields sizes for (60)Co γ-rays. A water phantom was employed to measure these parameters. An ionization chamber (IC) was used for calibration and comparison. A comparison of the resulting measurements with an ionization chamber's measured parameters showed good agreement. We thus believe that the tissue equivalent FBX dosimetry system can measure the dosimetric parameters for (60)Co with reasonable accuracy.

  16. An RF dosimeter for independent SAR measurement in MRI scanners.

    PubMed

    Qian, Di; El-Sharkawy, Abdel-Monem M; Bottomley, Paul A; Edelstein, William A

    2013-12-01

    The monitoring and management of radio frequency (RF) exposure is critical for ensuring magnetic resonance imaging (MRI) safety. Commercial MRI scanners can overestimate specific absorption rates (SAR) and improperly restrict clinical MRI scans or the application of new MRI sequences, while underestimation of SAR can lead to tissue heating and thermal injury. Accurate scanner-independent RF dosimetry is essential for measuring actual exposure when SAR is critical for ensuring regulatory compliance and MRI safety, for establishing RF exposure while evaluating interventional leads and devices, and for routine MRI quality assessment by medical physicists. However, at present there are no scanner-independent SAR dosimeters. An SAR dosimeter with an RF transducer comprises two orthogonal, rectangular copper loops and a spherical MRI phantom. The transducer is placed in the magnet bore and calibrated to approximate the resistive loading of the scanner's whole-body birdcage RF coil for human subjects in Philips, GE and Siemens 3 tesla (3T) MRI scanners. The transducer loop reactances are adjusted to minimize interference with the transmit RF field (B1) at the MRI frequency. Power from the RF transducer is sampled with a high dynamic range power monitor and recorded on a computer. The deposited power is calibrated and tested on eight different MRI scanners. Whole-body absorbed power vs weight and body mass index (BMI) is measured directly on 26 subjects. A single linear calibration curve sufficed for RF dosimetry at 127.8 MHz on three different Philips and three GE 3T MRI scanners. An RF dosimeter operating at 123.2 MHz on two Siemens 3T scanners required a separate transducer and a slightly different calibration curve. Measurement accuracy was ∼3%. With the torso landmarked at the xiphoid, human adult whole-body absorbed power varied approximately linearly with patient weight and BMI. This indicates that whole-body torso SAR is on average independent of the imaging

  17. Ceric and ferrous dosimeters show precision for 50-5000 rad range

    NASA Technical Reports Server (NTRS)

    Frigerio, N. A.; Henry, V. D.

    1968-01-01

    Ammonium thiocyanate, added to the usual ferrous sulfate dosimeter solution, yielded a very stable, precise and temperature-independent system eight times as sensitive as the classical Fricke system in the 50 to 5000 rad range. The ceric dosimeters, promising for use in mixed radiation fields, respond nearly independently of LET.

  18. Longevity Tests of High-Sensitivity BD-PND Bubble Dosimeters

    SciTech Connect

    Radev, R; Carlberg, E

    2002-07-09

    Medium- and very-high-sensitivity neutron bubble dosimeters (BD-PNDs) made by Bubble Technology Industries (BTI) were used to study the life span of such dosimeters in a standard setup with a {sup 252}Cf source. Although data on the longevity of bubble dosimeters with low and medium sensitivity exist, such data for dosimeters with high and very high sensitivity are not readily available. The manufacturer guarantees optimum dosimeter performance for 3 months after receipt. However, it is important to know the change in the dosimeters' characteristics with time, especially after the first 3 months. The long-term performance of four sets of very high sensitivity and one set of medium-sensitivity bubble dosimeters was examined for periods of up to 13 months. During that time, the detectors were exposed and reset more than 20 times. Although departures from initial detection sensitivity were observed in several cases, the detectors indicated a significantly longer life span than stated in the manufacturer's warranty. In addition, the change in the number of bubbles and in evaluated neutron dose as a function of the time from the end of exposure until the dosimeters were read was investigated.

  19. Comparative study of three types of civil defense high-range pocket dosimeters

    SciTech Connect

    Siskel, R.L.; Sims, C.S.; Swaja, R.

    1987-01-01

    Civil defense shelters are stocked with high-range (0- to 200-R) CDV-742 pocket dosimeters. These dosimeters are intended for use by people that must leave the shelter when the environmental radiation level is either high or unknown. A total of 67 CDV-742 dosimeters were obtained and studied during the summer of 1986 at Oak Ridge National Lab. Health Physics Research Reactor (HPRR). Three different types of dosimeters (27 Bendix, 20 Landsverk-Gold, and 20 Landsverk-Yellow) in various combinations were exposed to 14 separate pulse operations of the HPRR. It can be concluded that the CDV-742 type dosimeters were not suitable for use in a neutron or mixed radiation field unless the spectra is known and correction factors determined in this study are properly applied. Further study is needed to determine the accuracy of these dosimeters in a pure gamma field and to determine their precision at the extreme ends of the dosimeter range. Furthermore, because of their failure rates, shelter occupants should consider exposure data from the Bendix and Landsverk-Yellow dosimeters to be highly unreliable unless sufficient evidence exists to support the exposure readings.

  20. Adaptation of a Pocket PC for Use as a Wearable Voice Dosimeter

    ERIC Educational Resources Information Center

    Popolo, Peter S.; Svec, Jan G.; Titze, Ingo R.

    2005-01-01

    This article deals with the adaptation of a commercially available Pocket PC for use as a voice dosimeter, a wearable device that measures the vocal dose of teachers or other individuals on the job, at home, and elsewhere during the course of an entire day. An engineering approach for designing a voice dosimeter is described, and design data are…

  1. Adaptation of a Pocket PC for Use as a Wearable Voice Dosimeter

    ERIC Educational Resources Information Center

    Popolo, Peter S.; Svec, Jan G.; Titze, Ingo R.

    2005-01-01

    This article deals with the adaptation of a commercially available Pocket PC for use as a voice dosimeter, a wearable device that measures the vocal dose of teachers or other individuals on the job, at home, and elsewhere during the course of an entire day. An engineering approach for designing a voice dosimeter is described, and design data are…

  2. PRESAGETM - Development and optimization studies of a 3D radiochromic plastic dosimeter - Part 1

    NASA Astrophysics Data System (ADS)

    Adamovics, J.; Jordan, K.; Dietrich, J.

    2006-12-01

    This paper studies the polymerization of six different transparent plastics as potential 3D dosimeter matrices. In addition, six different leuco dyes and sixteen different free radical initiators were evaluated. Finally, the photoreactivity of the dosimeter was studied so that the effect of exposure to UV could be minimized.

  3. PRESAGETM - Development and optimization studies of a 3D radiochromic plastic dosimeter - Part 2

    NASA Astrophysics Data System (ADS)

    Adamovics, J.; Guo, P.; Burgess, D.; Manzoor, A.; Oldham, M.

    2006-12-01

    In a previous paper we described the evaluation of seven different transparent plastics as dosimeter matrices along with six different leuco dyes as the radiochromic agent. Here we present the evaluation of the dosimeter sensitivity and post irradiation stability of an additional plastic matrix and five different leuco dyes.

  4. Feasibility of Ultra-Thin Fiber-Optic Dosimeters for Radiotherapy Dosimetry

    PubMed Central

    Lee, Bongsoo; Kwon, Guwon; Shin, Sang Hun; Kim, Jaeseok; Yoo, Wook Jae; Ji, Young Hoon; Jang, Kyoung Won

    2015-01-01

    In this study, prototype ultra-thin fiber-optic dosimeters were fabricated using organic scintillators, wavelength shifting fibers, and plastic optical fibers. The sensor probes of the ultra-thin fiber-optic dosimeters consisted of very thin organic scintillators with thicknesses of 100, 150 and 200 μm. These types of sensors cannot only be used to measure skin or surface doses but also provide depth dose measurements with high spatial resolution. With the ultra-thin fiber-optic dosimeters, surface doses for gamma rays generated from a Co-60 therapy machine were measured. Additionally, percentage depth doses in the build-up regions were obtained by using the ultra-thin fiber-optic dosimeters, and the results were compared with those of external beam therapy films and a conventional fiber-optic dosimeter. PMID:26593917

  5. An analysis of an implantable dosimeter system for external beam therapy

    SciTech Connect

    Black, Robert D. . E-mail: bblack@siceltech.com; Scarantino, Charles W.; Mann, Gregory G.; Anscher, Mitchell S.; Ornitz, Robert D.; Nelms, Benjamin E.

    2005-09-01

    Background and Purpose: To review the data from an implantable radiation dosimetry system used in a clinical setting and to examine correlations between dosimeter readings and potential causative error sources. Materials and Methods: MOSFET (metal oxide semiconductor field effect transistor) based encapsulated dosimeters were evaluated in a phantom (in vitro) and in a study with 18 patients. The dosimeters were placed in the gross tumor volume or in collateral normal tissue. Predicted dose values were established by imaging the dosimeters in the planning CTs. Results: The in vitro study confirmed that bounding cumulative errors due to setup, planning, and machine output within a {+-}5% level is achievable. In patients, it was found that deviations from the targeted dose often exceeded the 5% level. Conclusions: The use of an implantable dosimeter system could provide an effective empiric check on the dose delivered at depth. Such a tool may have value for institutional quality assurance, as well as for therapy delivered to individual patients.

  6. Characterization of a Fricke dosimeter at high energy photon and electron beams used in radiotherapy.

    PubMed

    Moussous, O; Khoudri, S; Benguerba, M

    2011-12-01

    The dosimetric features of the Fricke dosimeter in clinical linear accelerator beams are considered. Experimental data were obtained using various nominal energies 6 and 18 MV, 12 and 15 MeV, including the (60)Co γ-ray beam. The calibration of the dosimeters was performed using the ionization chamber as a reference dosimeter. Some general characteristics of Fricke dosimeter such as energy dependence, optical density (OD)-dose relationship, reproducibility, accuracy, dose rate dependence were analyzed. The Fricke solution shows linearity in OD-dose relationship, energy independence and a good reproducibility over the energy range investigated. The Fricke dosimeter was found to be suitable for carrying out absorbed dose to water measurements in the calibration of high energy electron and photon beams.

  7. Effects of temperature and humidity during irradiation on the response of a film dosimeter

    NASA Astrophysics Data System (ADS)

    Khan, Hasan M.; Wahid, Mian S.

    1995-09-01

    A commercially available leuco dye containing polyvinyl butyral based film (FWT-63-02) has been investigated ctrophotometrically for its dosimetric characteristic and for its use as routine dosimeter in radiation processing for the absorbed dose range 0.1 to 10 kGy. The present study was carried out to evaluate the performance of dosimeter under different environmental conditions (i.e. effects of temperature and relative humidity during irradiation). The response was measured at peak wavelength of 600 nm as well as at a number of other wavelengths (550, 625, 640 and 650 nm). The dosimeter was found to show quite stable response up to a radiation chamber temperature of 40°C. The dosimeter also showed stable behavior at low or moderate relative humidity conditions (<76%) in the radiation chamber. The characteristics of the dosimeter are suitable for its possible application in radiation processing, food irradiation and sterilization applications.

  8. Feasibility of Ultra-Thin Fiber-Optic Dosimeters for Radiotherapy Dosimetry.

    PubMed

    Lee, Bongsoo; Kwon, Guwon; Shin, Sang Hun; Kim, Jaeseok; Yoo, Wook Jae; Ji, Young Hoon; Jang, Kyoung Won

    2015-11-17

    In this study, prototype ultra-thin fiber-optic dosimeters were fabricated using organic scintillators, wavelength shifting fibers, and plastic optical fibers. The sensor probes of the ultra-thin fiber-optic dosimeters consisted of very thin organic scintillators with thicknesses of 100, 150 and 200 μm. These types of sensors cannot only be used to measure skin or surface doses but also provide depth dose measurements with high spatial resolution. With the ultra-thin fiber-optic dosimeters, surface doses for gamma rays generated from a Co-60 therapy machine were measured. Additionally, percentage depth doses in the build-up regions were obtained by using the ultra-thin fiber-optic dosimeters, and the results were compared with those of external beam therapy films and a conventional fiber-optic dosimeter.

  9. A modified Fricke gel dosimeter for fast electron blood dosimetry

    NASA Astrophysics Data System (ADS)

    Del Lama, L. S.; de Góes, E. G.; Sampaio, F. G. A.; Petchevist, P. C. D.; de Almeida, A.

    2014-12-01

    It has been suggested for more than forty years that blood and blood components be irradiated before allogeneic transfusions for immunosuppressed patients in order to avoid the Transfusion-Associated Graft-versus-Host Disease (TA-GVHD). Whole blood, red blood cells, platelets and granulocytes may have viable T cells and should be irradiated before transfusion for different patient clinical conditions. According to international guides, absorbed doses from 25 up to 50 Gy should be delivered to the central middle plane of each blood bag. Although gamma and X-rays from radiotherapy equipments and dedicated cell irradiators are commonly used for this purpose, electron beams from Linear Accelerators (LINACs) could be used as well. In this work, we developed a methodology able to acquire dosimetric data from blood irradiations, especially after fast electrons exposures. This was achieved using a proposed Fricke Xylenol Gel (FXGp) dosimeter, which presents closer radiological characteristics (attenuation coefficients and stopping-powers) to the whole blood, as well as complete absorbed dose range linearity. The developed methodology and the FXGp dosimeter were also able to provide isodose curves and field profiles for the irradiated samples.

  10. Development and characterization of a three-dimensional radiochromic film stack dosimeter for megavoltage photon beam dosimetry

    SciTech Connect

    McCaw, Travis J. Micka, John A.; DeWerd, Larry A.

    2014-05-15

    Purpose: Three-dimensional (3D) dosimeters are particularly useful for verifying the commissioning of treatment planning and delivery systems, especially with the ever-increasing implementation of complex and conformal radiotherapy techniques such as volumetric modulated arc therapy. However, currently available 3D dosimeters require extensive experience to prepare and analyze, and are subject to large measurement uncertainties. This work aims to provide a more readily implementable 3D dosimeter with the development and characterization of a radiochromic film stack dosimeter for megavoltage photon beam dosimetry. Methods: A film stack dosimeter was developed using Gafchromic{sup ®} EBT2 films. The dosimeter consists of 22 films separated by 1 mm-thick spacers. A Virtual Water™ phantom was created that maintains the radial film alignment within a maximum uncertainty of 0.3 mm. The film stack dosimeter was characterized using simulations and measurements of 6 MV fields. The absorbed-dose energy dependence and orientation dependence of the film stack dosimeter were investigated using Monte Carlo simulations. The water equivalence of the dosimeter was determined by comparing percentage-depth-dose (PDD) profiles measured with the film stack dosimeter and simulated using Monte Carlo methods. Film stack dosimeter measurements were verified with thermoluminescent dosimeter (TLD) microcube measurements. The film stack dosimeter was also used to verify the delivery of an intensity-modulated radiation therapy (IMRT) procedure. Results: The absorbed-dose energy response of EBT2 film differs less than 1.5% between the calibration and film stack dosimeter geometries for a 6 MV spectrum. Over a series of beam angles ranging from normal incidence to parallel incidence, the overall variation in the response of the film stack dosimeter is within a range of 2.5%. Relative to the response to a normally incident beam, the film stack dosimeter exhibits a 1% under-response when the

  11. Radiological properties of the PRESAGE and PAGAT polymer dosimeters.

    PubMed

    Brown, S; Venning, A; De Deene, Y; Vial, P; Oliver, L; Adamovics, J; Baldock, C

    2008-12-01

    The radiological properties of the PRESAGE and PAGAT polymer dosimeters have been investigated and their water equivalence determined for use in radiotherapy dosimetry. The radiological water equivalence of each of the polymer dosimeters was determined by comparing the photon and electron interaction cross-sections over the 10 keV-20 MeV energy range and by Monte Carlo modelling the depth dose from a linear accelerator using the BEAMnrc software package. PRESAGE was found to have an effective Z-value and mass density (kgm(-3)) approximately 17% and 10% higher than water, respectively. A maximum difference of 85% was discovered in the photoelectric interaction probability curve of PRESAGE when compared to water over the energy range 10-100 keV, partially due to the Z(3) dependence of the photoelectric effect. The mass radiative stopping power ratios and mass scattering power ratios were both found to have less than 9% difference from water. The depth dose for PRESAGE from a 6MV photon beam had an absolute percentage difference to water of less than 2% and a relative percentage difference of less than 8%. The mass density of PAGAT was found to be 2.6% higher than water due to its high gelatine and monomer concentration. The cross-sectional attenuation and absorption coefficient ratios were found to be within 5% for energies between 10 and 100 keV and within 1% for energies between 100 keV and 20 MeV. The mass collisional stopping power, mass radiative stopping power and mass scattering power ratios were all less than 1% over the energy range studied. The depth dose had an absolute percentage difference to water of less than 1% and a relative percentage difference of less than 2.5%. These results indicate that the PAGAT polymer gel formulation is more radiological water equivalent than the PRESAGE formulation. However, the PRESAGE dosimeter offers some advantages in terms of ease of use and its lack of water equivalence may be overcome with dosimetric correction

  12. Characterization of the nanoDot OSLD dosimeter in CT

    SciTech Connect

    Scarboro, Sarah B.; Cody, Dianna; Followill, David; Court, Laurence; Stingo, Francesco C.; Kry, Stephen F.; Alvarez, Paola; Zhang, Di; McNitt-Gray, Michael

    2015-04-15

    Purpose: The extensive use of computed tomography (CT) in diagnostic procedures is accompanied by a growing need for more accurate and patient-specific dosimetry techniques. Optically stimulated luminescent dosimeters (OSLDs) offer a potential solution for patient-specific CT point-based surface dosimetry by measuring air kerma. The purpose of this work was to characterize the OSLD nanoDot for CT dosimetry, quantifying necessary correction factors, and evaluating the uncertainty of these factors. Methods: A characterization of the Landauer OSL nanoDot (Landauer, Inc., Greenwood, IL) was conducted using both measurements and theoretical approaches in a CT environment. The effects of signal depletion, signal fading, dose linearity, and angular dependence were characterized through direct measurement for CT energies (80–140 kV) and delivered doses ranging from ∼5 to >1000 mGy. Energy dependence as a function of scan parameters was evaluated using two independent approaches: direct measurement and a theoretical approach based on Burlin cavity theory and Monte Carlo simulated spectra. This beam-quality dependence was evaluated for a range of CT scanning parameters. Results: Correction factors for the dosimeter response in terms of signal fading, dose linearity, and angular dependence were found to be small for most measurement conditions (<3%). The relative uncertainty was determined for each factor and reported at the two-sigma level. Differences in irradiation geometry (rotational versus static) resulted in a difference in dosimeter signal of 3% on average. Beam quality varied with scan parameters and necessitated the largest correction factor, ranging from 0.80 to 1.15 relative to a calibration performed in air using a 120 kV beam. Good agreement was found between the theoretical and measurement approaches. Conclusions: Correction factors for the measurement of air kerma were generally small for CT dosimetry, although angular effects, and particularly effects due

  13. CCD imaging for optical tomography of gel radiation dosimeters.

    PubMed

    Wolodzko, J G; Marsden, C; Appleby, A

    1999-11-01

    Several investigations have been carried out by a number of researchers over the past few years to evaluate the utility of imaging gel dosimeters for the three-dimensional measurement of radiation fields. These have been proposed to be of particular value in mapping radiation dose distributions associated with emerging and complex approaches to cancer treatment such as conformal (CRT), intensity modulated (IMRT), "gamma knife," and pencil beam radiotherapies. Imaging of the gels has been successfully accomplished with clinical MRI units and via laser-based optical scanning. However, neither of these methods is generally accessible to all potential users, limiting the broader study and implementation of this valuable tool. We report here the design, methodology, and results of a preliminary study carried out to evaluate the utility of a new, inexpensive, and simplified approach to tomographic imaging of gel radiation dosimeters. For the purpose of this initial investigation, an array of liquid scintillation vials was prepared, containing a ferrous sulphate xylenol orange (FSX) gelatin formulation. The FSX formulation undergoes a change in optical absorption characteristics following irradiation, and the resulting color change can be observed visually. The vials were irradiated individually to different doses. Three-dimensional imaging was accomplished by tomographic reconstruction from two-dimensional optical images acquired using a diffuse, fluorescent light source, a digital charge-coupled device camera, single-photon-emission-computed tomography software, and other simple components designed by the authors. The resulting transverse images were evaluated through a region-of-interest (ROI) analysis to obtain the average change in image density in each vial as a function of radiation dose. These measured ROI values were subjected to a linear regression analysis to fit them to a straight line, and to determine the goodness of fit. Results from multiple imaging trials

  14. Characterization of the nanoDot OSLD dosimeter in CT

    PubMed Central

    Scarboro, Sarah B.; Cody, Dianna; Alvarez, Paola; Followill, David; Court, Laurence; Stingo, Francesco C.; Zhang, Di; Kry, Stephen F.

    2015-01-01

    Purpose: The extensive use of computed tomography (CT) in diagnostic procedures is accompanied by a growing need for more accurate and patient-specific dosimetry techniques. Optically stimulated luminescent dosimeters (OSLDs) offer a potential solution for patient-specific CT point-based surface dosimetry by measuring air kerma. The purpose of this work was to characterize the OSLD nanoDot for CT dosimetry, quantifying necessary correction factors, and evaluating the uncertainty of these factors. Methods: A characterization of the Landauer OSL nanoDot (Landauer, Inc., Greenwood, IL) was conducted using both measurements and theoretical approaches in a CT environment. The effects of signal depletion, signal fading, dose linearity, and angular dependence were characterized through direct measurement for CT energies (80–140 kV) and delivered doses ranging from ∼5 to >1000 mGy. Energy dependence as a function of scan parameters was evaluated using two independent approaches: direct measurement and a theoretical approach based on Burlin cavity theory and Monte Carlo simulated spectra. This beam-quality dependence was evaluated for a range of CT scanning parameters. Results: Correction factors for the dosimeter response in terms of signal fading, dose linearity, and angular dependence were found to be small for most measurement conditions (<3%). The relative uncertainty was determined for each factor and reported at the two-sigma level. Differences in irradiation geometry (rotational versus static) resulted in a difference in dosimeter signal of 3% on average. Beam quality varied with scan parameters and necessitated the largest correction factor, ranging from 0.80 to 1.15 relative to a calibration performed in air using a 120 kV beam. Good agreement was found between the theoretical and measurement approaches. Conclusions: Correction factors for the measurement of air kerma were generally small for CT dosimetry, although angular effects, and particularly effects due

  15. The responses of three kinds of passive dosimeters to secondary cosmic rays in the lower atmosphere.

    PubMed

    Yang, Zhen; Chen, Bo; Zhuo, Weihai; Fan, Dunhuang; Zhao, Chao; Zhang, Yu

    2015-12-01

    For accurate measurements of the secondary cosmic rays by using passive dosimeters, the relative responses of the thermoluminescence dosimeter (TLD), optically stimulated luminescence (OSL) dosimeter, and radiophotoluminescent glass dosimeter (RPLGD) were studied. The cosmic-ray shower generator was used to simulate the secondary cosmic rays at the sea level. Monte Carlo simulations were performed to calculate the air kerma and absorbed doses in each kind of dosimeter. The results showed that compared with their responses to gamma rays of (137)Cs, the relative responses of the TLD, OSL, and RPLGD were 0.786, 0.707, and 0.735 to the hard component of cosmic rays, respectively, and the values were 0.904, 0.838, and 0.857 to the soft component of cosmic rays, respectively. To verify the simulations results, an in situ measurement with the three kinds of dosimeters was performed at the same place. The results indicated that the secondary cosmic rays monitored with the three kinds of dosimeters were well consistent with each other provided their relative responses were taken into account.

  16. The responses of three kinds of passive dosimeters to secondary cosmic rays in the lower atmosphere

    SciTech Connect

    Yang, Zhen; Chen, Bo Zhuo, Weihai; Fan, Dunhuang; Zhang, Yu; Zhao, Chao

    2015-12-15

    For accurate measurements of the secondary cosmic rays by using passive dosimeters, the relative responses of the thermoluminescence dosimeter (TLD), optically stimulated luminescence (OSL) dosimeter, and radiophotoluminescent glass dosimeter (RPLGD) were studied. The cosmic-ray shower generator was used to simulate the secondary cosmic rays at the sea level. Monte Carlo simulations were performed to calculate the air kerma and absorbed doses in each kind of dosimeter. The results showed that compared with their responses to gamma rays of {sup 137}Cs, the relative responses of the TLD, OSL, and RPLGD were 0.786, 0.707, and 0.735 to the hard component of cosmic rays, respectively, and the values were 0.904, 0.838, and 0.857 to the soft component of cosmic rays, respectively. To verify the simulations results, an in situ measurement with the three kinds of dosimeters was performed at the same place. The results indicated that the secondary cosmic rays monitored with the three kinds of dosimeters were well consistent with each other provided their relative responses were taken into account.

  17. Feasibility study of a lead monoxide-based dosimeter for quality assurance in radiotherapy

    NASA Astrophysics Data System (ADS)

    Kim, K. T.; Han, M. J.; Heo, Y. J.; Park, J. E.; Lee, Y. K.; Kim, J. N.; Oh, K. M.; Cho, H. L.; Choi, Y. S.; Kim, J. Y.; Nam, S. H.; Park, S. K.

    2016-11-01

    Lately, cancer has been treated using high-energy radiation, and this requires highly reliable treatment plans. Therefore, a dosimeter with excellent performance, which is capable of precise dose measurement, is critical. In current clinical practices, an ionization chamber and diode utilizing the ionization reaction mechanism are widely used. Several studies have been carried out to determine optimal materials for the detector in a dosimeter to enable diagnostic imaging. Recently, studies with lead monoxide, which was shown to have low drift current and high resolving power at a high bias, were reported with the dosimeter exhibiting a fast response time against incident photons. This research aims to investigate the feasibility of a lead monoxide-based dosimeter for QA (quality assurance) in radiotherapy. In this paper, we report that the manufactured dosimeter shows similar linearity to a silicon diode and demonstrates similar characteristics in terms of PDD (percent depth dose) results for the thimble ionization chamber. Based on these results, it is demonstrated that the lead monoxide-based dosimeter complies with radiotherapy QA requirements, namely rapid response time, dose linearity, dose rate independence. Thus, we expect the lead monoxide-based dosimeter to be used commercially in the future.

  18. Monte Carlo-based energy response studies of diode dosimeters in radiotherapy photon beams.

    PubMed

    Arun, C; Palani Selvam, T; Dinkar, Verma; Munshi, Prabhat; Kalra, Manjit Singh

    2013-01-01

    This study presents Monte Carlo-calculated absolute and normalized (relative to a (60)Co beam) sensitivity values of silicon diode dosimeters for a variety of commercially available silicon diode dosimeters for radiotherapy photon beams in the energy range of (60)Co-24 MV. These values were obtained at 5 cm depth along the central axis of a water-equivalent phantom of 10 cm × 10 cm field size. The Monte Carlo calculations were based on the EGSnrc code system. The diode dosimeters considered in the calculations have different buildup materials such as aluminum, brass, copper, and stainless steel + epoxy. The calculated normalized sensitivity values of the diode dosimeters were then compared to previously published measured values for photon beams at (60)Co-20 MV. The comparison showed reasonable agreement for some diode dosimeters and deviations of 5-17 % (17 % for the 3.4 mm brass buildup case for a 10 MV beam) for some diode dosimeters. Larger deviations of the measurements reflect that these models of the diode dosimeter were too simple. The effect of wall materials on the absorbed dose to the diode was studied and the results are presented. Spencer-Attix and Bragg-Gray stopping power ratios (SPRs) of water-to-diode were calculated at 5 cm depth in water. The Bragg-Gray SPRs of water-to-diode compare well with Spencer-Attix SPRs for ∆ = 100 keV and above at all beam qualities.

  19. Feasibility study of a lead monoxide-based dosimeter for quality assurance in radiotherapy

    NASA Astrophysics Data System (ADS)

    Kim, K. T.; Han, M. J.; Heo, Y. J.; Park, J. E.; Lee, Y. K.; Kim, J. N.; Oh, K. M.; Cho, H. L.; Choi, Y. S.; Kim, J. Y.; Nam, S. H.; Park, S. K.

    2016-11-01

    Lately, cancer has been treated using high-energy radiation, and this requires highly reliable treatment plans. Therefore, a dosimeter with excellent performance, which is capable of precise dose measurement, is critical. In current clinical practices, an ionization chamber and diode utilizing the ionization reaction mechanism are widely used. Several studies have been carried out to determine optimal materials for the detector in a dosimeter to enable diagnostic imaging. Recently, studies with lead monoxide, which was shown to have low drift current and high resolving power at a high bias, were reported with the dosimeter exhibiting a fast response time against incident photons. This research aims to investigate the feasibility of a lead monoxide-based dosimeter for QA (quality assurance) in radiotherapy. In this paper, we report that the manufactured dosimeter shows similar linearity to a silicon diode and demonstrates similar characteristics in terms of PDD (percent depth dose) results for the thimble ionization chamber. Based on these results, it is demonstrated that the lead monoxide-based dosimeter complies with radiotherapy QA requirements, namely rapid response time, dose linearity, dose rate independence. Thus, we expect the lead monoxide-based dosimeter to be used commercially in the future.

  20. Ground-based evaluation of dosimeters for NASA high-altitude balloon flight

    NASA Astrophysics Data System (ADS)

    Straume, T.; Mertens, C. J.; Lusby, T. C.; Gersey, B.; Tobiska, W. K.; Norman, R. B.; Gronoff, G. P.; Hands, A.

    2016-11-01

    Results are presented from evaluations of radiation dosimeters prior to a NASA high-altitude balloon flight, the RaD-X mission. Four radiation dosimeters were on board RaD-X: a Far West Hawk (version 3), a Teledyne dosimeter (UDOS001), a Liulin dosimeter (MDU 6SA1), and a RaySure dosimeter (version 3b). The Hawk is a tissue-equivalent proportional counter (TEPC) and the others are solid-state Si sensors. The Hawk served as the "flight standard" and was calibrated for this mission. The Si-based dosimeters were tested to make sure they functioned properly prior to flight but were not calibrated for the radiation environment in the stratosphere. The dosimeters were exposed to 60Co gamma rays and 252Cf fission radiation (which includes both neutrons and gamma rays) at the Lawrence Livermore National Laboratory (LLNL). The measurement results were compared with results from standard "benchmark" measurements of the same sources and source-to-detector distances performed contemporaneously by LLNL calibration facility personnel. For 60Co gamma rays, the dosimeter-to-benchmark ratios were 0.84 ± 0.06, 1.07 ± 0.32, 1.31 ± 0.07, and 0.82 ± 0.24 for the TEPC, Teledyne, Liulin, and RaySure, respectively. For 252Cf radiation, the dosimeter-to-benchmark ratios were 0.94 ± 0.15, 0.55 ± 0.18, 0.58 ± 0.08, and 0.33 ± 0.12 for the TEPC, Teledyne, Liulin, and RaySure. Some examples of how the results were used to help interpret the flight data are also presented.

  1. An NMR relaxometry and gravimetric study of gelatin-free aqueous polyacrylamide dosimeters

    NASA Astrophysics Data System (ADS)

    Babic, Steven; Schreiner, L. John

    2006-09-01

    In conformal radiation therapy, a high dose of radiation is given to a target volume to increase the probability of cure, and care is taken to minimize the dose to surrounding healthy tissue. The techniques used to achieve this are very complicated and the precise verification of the resulting three-dimensional (3D) dose distribution is required. Polyacrylamide gelatin (PAG) dosimeters with magnetic resonance imaging and optical computed tomography scanning provide the required 3D dosimetry with high spatial resolution. Many basic studies have characterized these chemical dosimeters that polymerize under irradiation. However, the investigation of the fundamental properties of the radiation-induced polymerization in PAG dosimeters is complicated by the presence of the background gelatin matrix. In this work, a gelatin-free model system for the study of the basic radiation-induced polymerization in PAG dosimeters has been developed. Experiments were performed on gelatin-free dosimeters, named aqueous polyacrylamide (APA) dosimeters, containing equal amounts of acrylamide and N,N'-methylene-bisacrylamide. The APA dosimeters were prepared with four different total monomer concentrations (2, 4, 6 and 8% by weight). Nuclear magnetic resonance (NMR) spin-spin and spin-lattice proton relaxation measurements at 20 MHz, and gravimetric analyses performed on all four dosimeters, show a continuous degree of polymerization over the dose range of 0-25 Gy. The developed NMR model explains the relationship observed between the relaxation data and the amount of crosslinked polymer formed at each dose. This model can be extended with gelatin relaxation data to provide a fundamental understanding of radiation-induced polymerization in the conventional PAG dosimeters.

  2. Applicability of the Sunna dosimeter for food irradiation control

    NASA Astrophysics Data System (ADS)

    Kovács, A.; Baranyai, M.; Wojnárovits, L.; Miller, S.; Murphy, M.; McLaughlin, W. L.; Slezsák, I.; Kovács, A. I.

    2002-03-01

    The quick development concerning the commercial application of food irradiation in the USA recently resulted in growing marketing of irradiated red meat as well as irradiated fresh and dried fruits. These gamma and electron irradiation technologies require specific dosimetry systems for process control. The new version of the Sunna dosimeter has been characterized in gamma, electron and bremsstrahlung radiation fields by measuring the optically stimulated luminescence (osl) at 530 nm both below and above 1 kGy, i.e. for disinfestation and for meat irradiation purposes. No humidity and no significant dose rate effect on the green osl signal was observed. The temperature coefficient was determined from 0°C up to about 40°C and to stabilize the osl signal after irradiation a heat treatment method was introduced. Based on these investigations the Sunna 'gamma' film is a suitable candidate for dose control below and above 1 kGy for food irradiation technologies.

  3. Solid state dosimeters used in medical physics 'A review'

    SciTech Connect

    Azorin-Nieto, Juan

    2012-10-23

    Many solid-state detectors have been successfully used to perform the quality control and in vivo dosimetry in medical physics, both in diagnostic radiology and radiotherapy, as they have high sensitivity in a small volume; most of them do not require electrical connection and have dosimetric characteristics of interest such as: good accuracy and reproducibility, as well as a response independent of the energy of radiation, some of them. For this reason, the selection of an appropriate detector for use in medical physics must take into account the energy mass absorption coefficient relative to water for photon sources and the mass stopping power relative to water for beta emitters and electron beams in the energy range of interest in medical physics, as well as the effective atomic number of materials that constitute them. This paper presents a review of the dosimetric characteristics of the solid state dosimeters most suitable for use in medical physics.

  4. Electron absorbed dose measurements in LINACs by thermoluminescent dosimeters.

    PubMed

    Cortés, J Rodríguez; Romero, R Alvarez; Nieto, J Azorín; Montalvo, T Rivera

    2014-01-01

    In this work, electron absorbed doses measurements in radiation therapy (RT) were obtained. Radiation measurements were made using thermoluminescent dosimeters of calcium sulfate doped with dysprosium (CaSO4:Dy) and zirconium oxide (ZrO2). TL response calibration was obtained by irradiating TLDs and a Farmer cylindrical ionization chamber PTW 30013 at the same time. Each TL material showed a typical glow curve according to each material. Both calcium sulfate doped with dysprosium and zirconium oxide exhibited better light intensity to high energy electron beam compared with lithium fluoride. TL response as a function of absorbed dose was analyzed. TL response as a function of high energy electron beam was also studied. © 2013 Published by Elsevier Ltd.

  5. A Radiation Dosimeter Concept for the Lunar Surface Environment

    NASA Technical Reports Server (NTRS)

    Adams, James H.; Christl, Mark J.; Watts, John; Kuznetsov, Eugeny N.; Parnell, Thomas A.; Pendleton, Geoff N.

    2007-01-01

    A novel silicon detector configuration for radiation dose measurements in an environment where solar energetic particles are of most concern is described. The dosimeter would also measure the dose from galactic cosmic rays. In the lunar environment a large range in particle flux and ionization density must be measured and converted to dose equivalent. This could be accomplished with a thick (e.g. 2mm) silicon detector segmented into cubic volume elements "voxels" followed by a second, thin monolithic silicon detector. The electronics needed to implement this detector concept include analog signal processors (ASIC) and a field programmable gate array (FPGA) for data accumulation and conversion to linear energy transfer (LET) spectra and to dose-equivalent (Sievert). Currently available commercial ASIC's and FPGA's are suitable for implementing the analog and digital systems.

  6. Turnbull Blue Gel (TBG) evaluation as optical dosimeter

    NASA Astrophysics Data System (ADS)

    Borguezan Neto, E.; Batistuti, M. R.; Pavoni, J. F.; Bachmann, L.

    2017-05-01

    The radiochromic Turnbull Blue Gel (TBG) is sensitive to X- and γ-rays. When exposed to high-energy radiation, TBG can simulate biological tissues, so this gel has potential use in ionizing radiation dosimetry. After irradiation, the yellow TBG changes to the blue Turnbull Blue dye. This work aims to evaluate how TBG responds to exposure to ultraviolet, visible, and infrared radiation from the sun. The gel was irradiated with a solar simulator, which sensitized TBG and transformed it into the Turnbull Blue dye; a change in the optical absorption ensued. The fluence values delivered by the source did not provide a linear response, but it was still possible to use TBG as an optical dosimeter. In conclusion, TBG can be applied to detect solar radiation because it is sensitive enough to measure sun exposure values at time intervals of few minutes.

  7. Evaluation of commercial programmable floating gate devices as radiation dosimeters

    NASA Astrophysics Data System (ADS)

    Edgecock, R.; Matheson, J.; Weber, M.; Giulio Villani, E.; Bose, R.; Khan, A.; Smith, D. R.; Adil-Smith, I.; Gabrielli, A.

    2009-02-01

    Programmable floating gate MOSFET transistors were tested with gamma radiation with doses up to approximately 100Gy (air equivalent), to evaluate their suitability as dosimeters in radiotherapy. After characterization and programming at different threshold voltages, the devices were irradiated and their Vgs shift with dose monitored in real time. Post-irradiation analysis was carried out to evaluate sensitivity, linearity, reproducibility and voltage threshold annealing. A subsequent re-programming phase followed by characterization was performed to asses their post-irradiation charge restoring capabilities. It was found that up to 73% of the initial maximum threshold voltage could be recovered. A sensitivity of up to 9 mV/Gy with an uncertainty of less than 1%, an excellent linearity up to the maximum programmable threshold voltage and low noise suggest the use of this technology for in vivo dosimetry applications.

  8. Dental enamel as an in vivo radiation dosimeter

    SciTech Connect

    Pass, B.; Aldrich, J.E.

    1985-05-01

    The determination of the radiation exposure history of the population has become increasingly important in the study of the effects of low-level radiation. The present work was started to try to obtain an in vivo dosimeter that could give an indication of radiation exposure. Dental enamel is the only living tissue which retains indefinitely its radiation history, and electron spin resonance measurements have shown that the radiation signal can be resolved down to about 10 cGy. Measurements on samples from the general population give radiation exposure estimates that are reasonable, and one measurement on a patient who had radiotherapy to the mouth area showed a good correlation with tumor dose.We believe that this is an important new indicator of radiation dose and taken together with exposure histories should provide important data for epidemiological studies as well as accidental exposures.

  9. Energy dependence of metallic-encapsulated thermoluminescent dosimeters. Annual report

    SciTech Connect

    Simons, G.G.

    1980-06-01

    The gamma-ray energy responses of encapsulated /sup 7/LiF and CaF/sub 2/:Mn thermoluminescent dosimeters were measured and compred to calculated values. This study was performed in order to improve the accuracy of gamma-ray heating measurements made in polyenergetic gamma-ray fields such as Argonne National Laboratory's Zero Power Reactors. Equations used in the development of the TERC/III computer code and code input parameters are specified. A section on TLD precision is also included. Comparisons between calculations and experiments are reported for a gamma-ray energy range of 0.122 to 1.33 MeV and encasement media with a range of atomic numbers from 13 to 82.

  10. Non-diffusing radiochromic leuco-crystal violet hydrogel dosimeter

    NASA Astrophysics Data System (ADS)

    Jordan, K. J.; Lindenmaier, T.; Dekker, K. H.

    2017-05-01

    A systematic study to prepare mixed-micelle, radiochromic hydrogels found that non-diffusing dosimeters can be prepared. Subsequent experiments determined that sodium dodecyl sulfate (SDS) a negatively charged surfactant, binds positively charged crystal violet dye to gelatin below the critical micelle concentration. A typical formulation includes: 4% gelatin by mass, 1 mM hydrogen peroxide, 1 mM SDS, 1 mM leuco crystal violet (LCV) and 25 mM trichloroacetic acid (TCAA). This transparent material has an initial attenuation coefficient of 0.08 cm-1 and dose sensitivity of 0.015 cm-1 Gy-1. Which is a doubling of the dose sensitivity from the initial formulation with uncharged Triton X100 micelles. Reconstructed beam profiles from 3D optical CT scans performed 1, 14 and 85 hours post irradiation demonstrate no diffusion of the recorded dose distribution.

  11. Review of four novel dosimeters developed for use in radiotherapy

    NASA Astrophysics Data System (ADS)

    Metcalfe, P.; Quinn, A.; Loo, K.; Lerch, M.; Petasecca, M.; Wong, J.; Hardcastle, N.; Carolan, M.; McNamara, J.; Cutajar, D.; Fuduli, I.; Espinoza, A.; Porumb, C.; Rosenfeld, A.

    2013-06-01

    Centre for Medical Radiation Physics (CMRP) is a research strength at the University of Wollongong, the main research theme of this centre is to develop prototype novel radiation dosimeters. Multiple detector systems have been developed by Prof Rosenfelds' group for various radiation detector applications. This paper focuses on four current detector systems being developed and studied at CMRP. Two silicon array detectors include the magic plate and dose magnifying glass (DMG), the primary focus of these two detectors is high spatial and temporal resolution dosimetry in intensity modulated radiation therapy (IMRT) beams. The third detector discussed is the MOSkinTM which is a high spatial resolution detector based on MOSFET technology, its primary role is in vivo dosimetry. The fourth detector system discussed is BrachyView, this is a high resolution dose viewing system based on Medipix detector technology.

  12. New technique to improve the accuracy of albedo neutron dosimeter evaluations

    NASA Astrophysics Data System (ADS)

    Hankins, D. E.

    The calibration factor for albedo neutron dosimeters varies greatly depending upon the energy of the neutrons in the exposure. Calibration results obtained over an eight-year period at each Lawrence Livermore National Laboratory facility where neutron exposure may occur were reviewed. A stronger relationship than expected was found between the ratio of the readings of the 9-in. to 3-in. spheres and the percent thermal. Readings from personnel and albedo badges were reviewed. The readings were consistent with the use of a calibration factor for the albedo dosimeter which varies with changes in the ratio of the personnel and albedo dosimeter TLD readings.

  13. Measurement of a 200 MeV proton beam using a polyurethane dosimeter

    NASA Astrophysics Data System (ADS)

    Heard, Malcolm; Adamovics, John; Ibbott, Geoffrey

    2006-12-01

    PRESAGETM (Heuris Pharma LLC, Skillman, NJ) is a three-dimensional polyurethane dosimeter containing a leuco dye that generates a color change when irradiated. The dosimeter is solid and does not require a container to maintain its shape. The dosimeter is transparent before irradiation and the maximum absorbance of the leuco dye occurs at 633 nm which is compatible with the OCT-OPUSTM laser CT scanner (MGS Research, Inc., Madison, CT). The purpose of this study was to investigate the response of PRESAGETM to proton beam radiotherapy.

  14. Investigation of on-chip high temperature annealing of PMOS dosimeters

    SciTech Connect

    Kelleher, A.; Lane, W.; Adams, L.K.

    1996-06-01

    Radiation sensitive pMOS dosimeters can measure only to a maximum dose which is determined by the type, sensitivity and irradiation conditions of the RADFET. On reaching the maximum dose, the dosimeters normally have to be replaced. The aim of this work is to study the feasibility of using on-chip poly-resistor heaters to anneal the dosimeters back to their pre-irradiation threshold voltage. This study shows that, on-chip heating is a viable option to achieve post-irradiation annealing, and that the fading characteristics obtained agree with those of oven annealing from a previous study which was carried out on the NMRC RADFETs.

  15. Calibration factors for the SNOOPY NP-100 neutron dosimeter

    NASA Astrophysics Data System (ADS)

    Moscu, D. F.; McNeill, F. E.; Chase, J.

    2007-10-01

    Within CANDU nuclear power facilities, only a small fraction of workers are exposed to neutron radiation. For these individuals, roughly 4.5% of the total radiation equivalent dose is the result of exposure to neutrons. When this figure is considered across all workers receiving external exposure of any kind, only 0.25% of the total radiation equivalent dose is the result of exposure to neutrons. At many facilities, the NP-100 neutron dosimeter, manufactured by Canberra Industries Incorporated, is employed in both direct and indirect dosimetry methods. Also known as "SNOOPY", these detectors undergo calibration, which results in a calibration factor relating the neutron count rate to the ambient dose equivalent rate, using a standard Am-Be neutron source. Using measurements presented in a technical note, readings from the dosimeter for six different neutron fields in six source-detector orientations were used, to determine a calibration factor for each of these sources. The calibration factor depends on the neutron energy spectrum and the radiation weighting factor to link neutron fluence to equivalent dose. Although the neutron energy spectra measured in the CANDU workplace are quite different than that of the Am-Be calibration source, the calibration factor remains constant - within acceptable limits - regardless of the neutron source used in the calibration; for the specified calibration orientation and current radiation weighting factors. However, changing the value of the radiation weighting factors would result in changes to the calibration factor. In the event of changes to the radiation weighting factors, it will be necessary to assess whether a change to the calibration process or resulting calibration factor is warranted.

  16. Characterization of metal oxide semiconductor field effect transistor dosimeters for application in clinical mammography.

    PubMed

    Benevides, Luis A; Hintenlang, David E

    2006-02-01

    Five high-sensitivity metal oxide semiconductor field effect transistor dosimeters in the TN-502 and 1002 series (Thomson Nielsen Electronics Ltd., 25B, Northside Road, Ottawa, ON K2H8S1, Canada) were evaluated for use in the mammography x-ray energy range (22-50 kVp) as a tool to assist in the documentation of patient specific average glandular dose. The dosimeters were interfaced with the Patient Dose Verification System, model No. TN-RD 15, which consisted of a dosimeter reader and up to four dual bias power supplies. Two different dual bias power supplies were evaluated in this study, model No. TN-RD 22 in high-sensitivity mode and a very-high sensitivity prototype. Each bias supply accommodates up to five dosimeters for 20 dosimeters per system. Sensitivity of detectors, defined as the mV/C kg(-1), was measured free in air with the bubble side of the dosimeter facing the x-ray field with a constant exposure. All dosimeter models' angular response showed a marked decrease in response when oriented between 120 degrees and 150 degrees and between at 190 degrees and 220 degrees relative to the incident beam. Sensitivity was evaluated for Mo/Mo, Mo/Rh, and Rh/Rh target-filter combinations. The individual dosimeter model sensitiVity was 4.45 x 10(4) mV/C kg(-1) (11.47 mV R(-1)) for TN-502RDS(micro); 5.93 x 10(4) mV per C kg(-1) (15.31 mV R(-1)) for TN-1002RD; 6.06 x 10(4) mV/C kg(-1) (15.63 mV R(-1)) for TN-1002RDI; 9.49 x 10(4) mV per C kg(-1) (24.49 mV R(-1)) for TN-1002RDM (micro); and 11.20 x 10(4) mV/C kg(-1) (28.82 mV R(-1)) for TN-1002RDS (micro). The energy response is presented and is observed to vary with dosimeter model, generally increasing with tube potential through the mammography energy range. An intercomparison of the high-sensitivity mode of TN-RD-22 was made to the very-high sensitivity bias power supply using a Mo/Mo target-filter. The very-high sensitivity-bias power supply increased dosimeter response by 1.45 +/- 0.04 for dosimeter models TN

  17. Evaluation of external dose equivalent with thermoluminescent dosimeters from residents living in radiation-contaminated buildings.

    PubMed

    Lee, J S; Dong, S L; Chang, W P; Chan, C C

    1997-09-01

    As of October 1996 there are more than 90 radiation-contaminated steel supported rebar buildings (containing more than 1000 apartments) dispersed in the northern part of Taiwan. These apartments were contaminated with cobalt-60 at a total activity ranging from 1-140 microSv/yr. In this paper, a method is developed for evaluating external dose equivalent and dose equivalent rates encountered by the residents wearing specially designed thermoluminescent dosimeter (TLD)-embedded chains, belts and badges. Comparisons are also made between the TLD readings and the exposure readings from indoor layout personal dosimetry surveys and room occupancy adjustments to the buildings. The accuracy and sensitivity of the TLDs compared with the ionization chamber readings are judged to be considerable improvements over those of previous studies. From the present study, it is concluded that the reliability of the daily activity records provided by the residents during the entire TLD-wearing period is the most critical but challenging feature of the external dose equivalent measurement.

  18. An intercomparison of neutron dosimeters and detectors for in-containment dosimetry

    SciTech Connect

    Auman, L.E.; Miller, W.H.; Graham, C.C.; Stretch, C.D.; Welty, T.J.; West, L. Jr. )

    1992-02-01

    To improve the methodology for assessing neutron dose at Union Electric's Callaway Nuclear Power Plant, an intercomparison of neutron detectors and dosimeters was performed. Seven different neutron detectors and dosimeters were tested in four different neutron fields utilizing facilities at the Missouri University Research Reactor and at the Southwest Radiation Calibration Center at the University of Arkansas. In general, all results agree within a factor of 2 in predicting the neutron dose equivalent. It was concluded that measurements of dose in containment should utilize the Tissue-Equivalent Proportional Counter (TEPC), the Bonner-sphere system, and the proton recoil spectrometer to accurately assess the neutron dose. These data can then be used to provide correction factors for more traditionally used dosimeters in containment, such as thermoluminescent dosimeters and survey meters.

  19. Development and evaluation of a microprocessor-based ergonomic dosimeter for evaluating carpentry tasks.

    PubMed

    Bhattacharya, A; Warren, J; Teuschler, J; Dimov, M; Medvedovic, M; Lemasters, G

    1999-12-01

    This portable and self-contained lightweight microprocessor based Ergonomic Dosimeter is designed to collect continuously postural angles of the torso and the upper arm in the sagittal plane and the number of kneeling activities. Up to 4 h of task performance data can be stored in a non-volatile memory of the dosimeter, which can then be downloaded to a lap-top computer. The portable dosimeter was tested for test-retest reliability, compared with posture data obtained with a computer-based video analysis system and evaluated at a carpenter's apprentices school and at a construction site. The dosimeter was shown to be suitable for collecting posture and kneeling data for a prolonged period at construction sites.

  20. Radiation dose enhancement of gold nanoparticle on different polymer gel dosimeters

    NASA Astrophysics Data System (ADS)

    Jabaseelan Samuel, E. James; Srinivasan, K.; Poopathi, V.

    2017-05-01

    In this work, we evaluated the dose enhancement produced by gold nanoparticle on ten different polymer gel dosimeters with a concentration of 7mgAu /g over a wide photon energy range of 15KeV to 20MeV and the results were compared with Soft tissue ICRU-44 produced. Our result showed that maximum DEF was observed at 40KeV, while it was almost negligible at higher energy range. Dose enhancement produced by AuNP on the gel dosimeter medium was varied compared to the reference ICRU-44 tissue, it was ± <1% for PAGAT, NIPAM, nPAG and ± <5% for PABIG, VIPAR, HEAG, BANG1, nMAG & ± <10% for MAGIC, ABAGIC gel dosimeters. Hence, we conclude that choosing the proper gel dosimeter is essential in dose enhancement study.

  1. Novel radiochromic dosimeters based on Calcein dye for high dose applications

    NASA Astrophysics Data System (ADS)

    Aldweri, Feras M.; Rabaeh, Khalid A.; Al-Ahmad, Kefaia N.

    2017-10-01

    New compositions of radio-chromic solutions and polyvinyl alcohol (PVA) films containing different concentrations of Calcein dye have been introduced as high dose dosimeter. The dosimeters were irradiated with gamma rays from 60C o source at doses from 5 to 30 kGy for film and from 0.25 to 1 kGy for solution. UV/vis spectrophotometry was used to investigate the absorbance (optical density) of unirradiated and irradiated films and solutions in terms of absorbance at 493 nm for film and 496 nm for solution. The effects of scan temperature, relative humidity and stability of the response of films and solutions after irradiation were investigated. The results show that these films could be used as dosimeter in industrial radiation processing. The useful dose range of developed Calcein-PVA film and solution dosimeters is in the range of 5-20 kGy and 0.25-1 kGy respectively

  2. New polymer gel dosimeters consisting of less toxic monomers with radiation-crosslinked gel matrix

    NASA Astrophysics Data System (ADS)

    Hiroki, A.; Yamashita, S.; Sato, Y.; Nagasawa, N.; Taguchi, M.

    2013-06-01

    New polymer gel dosimeters consisting of less toxic methacrylate-type monomers such as 2-hydroxymethyl methacrylate (HEMA) and polyethylene glycol 400 dimethacrylate (9G) with hydroxypropyl cellulose (HPC) gel were prepared. The HPC gels were obtained by using a radiation-induced crosslinking technique to be applied in a matrix instead of a gelatin, which is conventionally used in earlier dosimeters, for the polymer gel dosimeters. The prepared polymer gel dosimeters showed cloudiness by exposing to 60Co γ-ray, in which the cloudiness increased with the dose up to 10 Gy. At the same dose, the increase in the cloudiness appeared with increasing concentration of 9G. As a result of the absorbance measurement, it was found that the dose response depended on the composition ratio between HEMA and 9G.

  3. A design solution to increasing the sensitivity of pMOS dosimeters: The stacked RADFET approach

    SciTech Connect

    Kelleher, A.; Lane, W.; Adams, L.

    1995-02-01

    pMOS Radiation Sensitive Field Effect Transistors (RADFET`S) have applications as integrating dosimeters in laboratories and medicine to measure the amount of radiation dose absorbed. The suitability of these dosimeters to a certain application depends on the sensitivity of the RADFET being used. To date, this sensitivity is limited to the sensitivity of the gate oxide to radiation. The aim of this paper is to introduce a new design approach which will allow greater sensitivities to be achieved than is currently possible. An additional attractive feature of this design approach is that the sensitivity of the dosimeter may be changed depending on the total dose which is to be measured; essentially a dosimeter with auto-scaling may be achieved. This study introduces this autoscaling concept along with presenting the optimum RADFET device requirements which are necessary for this new design approach.

  4. Novel composition of polymer gel dosimeters based on N-(Hydroxymethyl)acrylamide for radiation therapy

    NASA Astrophysics Data System (ADS)

    Basfar, Ahmed A.; Moftah, Belal; Rabaeh, Khalid A.; Almousa, Akram A.

    2015-07-01

    A new composition of polymer gel dosimeters is developed based on radiation induced polymerization of N-(Hydroxymethyl)acrylamide (NHMA) for radiotherapy treatment planning. The dosimeters were irradiated by 10 MV photon beam of a medical linear accelerator at a constant dose rate of 600 cGy/min with doses up to 20 Gy. The polymerization occurs and increases with increasing absorbed dose. The dose response of polymer gel dosimeters was studied using nuclear magnetic imaging (NMR) for relaxation rate (R2) of water proton. Dose rate, energy of radiation and the stability of the polymerization after irradiation were investigated. No appreciable effects of these parameters on the performance of the novel gel dosimeters were observed.

  5. Neutron Fading Characteristics of Copper Doped Lithium Fluoride (LiF: MCP) Thermoluminescent Dosimeters (TLDs)

    DTIC Science & Technology

    2008-05-21

    Fading Characteristics of Copper-Doped Lithium Fluoride (LiF: MCP) Thermoluminescent Dosimeters (TLDs)" Name of Candidate: L T Jeffrey A. Delzer Master...Lithium Fluoride Thermoluminescent Dosimeters beyond brief excerpts is with the permission of the copyright owner, and will save and hold harmless...Thesis: Author: Thesis directed by: ABSTRACT "Neutron Fading Characteristics of Copper-Doped Lithium Fluoride (LiF: MCP) Thermoluminescent

  6. Performance of KCl:Eu2+ storage phosphor dosimeters for low-dose measurements

    NASA Astrophysics Data System (ADS)

    Li, H. Harold; Xiao, Zhiyan; Hansel, Rachael; Knutson, Nels; Yang, Deshan

    2013-06-01

    Recent research has demonstrated that europium doped potassium chloride (KCl:Eu2+) storage phosphor material has the potential to become the physical foundation of a novel and reusable dosimetry system using either film-like devices or devices similar to thermoluminescent dosimeter chips. The purposes of this work are to quantify the performance of KCl:Eu2+ prototype dosimeters for low-dose measurements and to demonstrate how it can be incorporated into clinical application for in vivo peripheral dose measurements. Pellet-style KCl:Eu2+ dosimeters, 6 mm in diameter, and 1 mm thick, were fabricated in-house for this study. The dosimeters were read using a laboratory photostimulated luminescence detection system. KCl:Eu2+ prototype storage phosphor dosimeter was capable of measuring a dose-to-water as low as 0.01 cGy from a 6 MV photon beam with a signal-to-noise ratio greater than 6. A pre-readout thermal annealing procedure enabled the dosimeter to be read within an hour post-irradiation. After receiving large accumulated doses (˜10 kGy), the dosimeters retained linear response in the low-dose region with only a 20% loss of sensitivity comparing to a fresh sample (zero Gy history). The energy dependence encountered during low-dose peripheral measurements could be accounted for via a single point outside-field calibration per each beam quality. With further development the KCl:Eu2+--based dosimeter could become a versatile and durable dosimetry tool with large dynamic range (sub-cGy to 100 Gy).

  7. Characterization of a water-equivalent fiber-optic coupled dosimeter for use in diagnostic radiology

    SciTech Connect

    Hyer, Daniel E.; Fisher, Ryan F.; Hintenlang, David E.

    2009-05-15

    This work reports on the characterization of a new fiber-optic coupled (FOC) dosimeter for use in the diagnostic radiology energy range. The FOC dosimeter was constructed by coupling a small cylindrical plastic scintillator, 500 {mu}m in diameter and 2 mm in length, to a 2 m long optical fiber, which acts as a light guide to transmit scintillation photons from the sensitive element to a photomultiplier tube (PMT). A serial port interface on the PMT permits real-time monitoring of light output from the dosimeter via a custom computer program. The FOC dosimeter offered excellent sensitivity and reproducibility, allowing doses as low as 0.16 mGy to be measured with a coefficient of variation of only 3.64%. Dose linearity was also excellent with a correlation coefficient of 1.000 over exposures ranging from 0.16 to 57.29 mGy. The FOC dosimeter exhibited little angular dependence from axial irradiation, varying by less than 5% over an entire revolution. A positive energy dependence was observed and measurements performed within a scatter medium yielded a 10% variation in sensitivity as beam quality changed due to hardening and scatter across a 16 cm depth range. The current dosimetry system features an array of five PMTs to allow multiple FOC dosimeters to be monitored simultaneously. Overall, the system allows for rapid and accurate dose measurements relevant to a range of diagnostic imaging applications.

  8. Small-Field Measurements of 3D Polymer Gel Dosimeters through Optical Computed Tomography

    PubMed Central

    Shih, Cheng-Ting; Lee, Yao-Ting; Wu, Shin-Hua; Yao, Chun-Hsu; Hsieh, Bor-Tsung

    2016-01-01

    With advances in therapeutic instruments and techniques, three-dimensional dose delivery has been widely used in radiotherapy. The verification of dose distribution in a small field becomes critical because of the obvious dose gradient within the field. The study investigates the dose distributions of various field sizes by using NIPAM polymer gel dosimeter. The dosimeter consists of 5% gelatin, 5% monomers, 3% cross linkers, and 5 mM THPC. After irradiation, a 24 to 96 hour delay was applied, and the gel dosimeters were read by a cone beam optical computed tomography (optical CT) scanner. The dose distributions measured by the NIPAM gel dosimeter were compared to the outputs of the treatment planning system using gamma evaluation. For the criteria of 3%/3 mm, the pass rates for 5 × 5, 3 × 3, 2 × 2, 1 × 1, and 0.5 × 0.5 cm2 were as high as 91.7%, 90.7%, 88.2%, 74.8%, and 37.3%, respectively. For the criteria of 5%/5 mm, the gamma pass rates of the 5 × 5, 3 × 3, and 2 × 2 cm2 fields were over 99%. The NIPAM gel dosimeter provides high chemical stability. With cone-beam optical CT readouts, the NIPAM polymer gel dosimeter has potential for clinical dose verification of small-field irradiation. PMID:26974434

  9. Characterization of a water-equivalent fiber-optic coupled dosimeter for use in diagnostic radiology.

    PubMed

    Hyer, Daniel E; Fisher, Ryan F; Hintenlang, David E

    2009-05-01

    This work reports on the characterization of a new fiber-optic coupled (FOC) dosimeter for use in the diagnostic radiology energy range. The FOC dosimeter was constructed by coupling a small cylindrical plastic scintillator, 500 microm in diameter and 2 mm in length, to a 2 m long optical fiber, which acts as a light guide to transmit scintillation photons from the sensitive element to a photo-multiplier tube (PMT). A serial port interface on the PMT permits real-time monitoring of light output from the dosimeter via a custom computer program. The FOC dosimeter offered excellent sensitivity and reproducibility, allowing doses as low as 0.16 mGy to be measured with a coefficient of variation of only 3.64%. Dose linearity was also excellent with a correlation coefficient of 1.000 over exposures ranging from 0.16 to 57.29 mGy. The FOC dosimeter exhibited little angular dependence from axial irradiation, varying by less than 5% over an entire revolution. A positive energy dependence was observed and measurements performed within a scatter medium yielded a 10% variation in sensitivity as beam quality changed due to hardening and scatter across a 16 cm depth range. The current dosimetry system features an array of five PMTs to allow multiple FOC dosimeters to be monitored simultaneously. Overall, the system allows for rapid and accurate dose measurements relevant to a range of diagnostic imaging applications.

  10. N-isopropylacrylamide gel dosimeter to evaluate clinical photon beam characteristics.

    PubMed

    Chiu, Chung-Yu; Tsang, Yuk-Wah; Hsieh, Bor-Tsung

    2014-08-01

    The introduction of beam intensity control concept in current radiotherapy techniques has increased treatment planning complexity. Thus, small-field dose measurement has become increasingly vital. Polymer gel dosimetry method is widely studied. It is the only dose measurement tool that provides 3D dose distribution. This study aims to use an N-isopropylacrylamide (NIPAM) gel dosimeter to conduct beam performance measurements of percentage depth dose (PDD), beam flatness, and symmetry for photon beams with field sizes of 3×3 and 4×4 cm(2). Computed tomography scans were used to readout the gel dosimeters. In the PDD measurement, the NIPAM gel dosimeter and Gafchromic™ EBT3 radiochromic film displayed high consistency in the region deeper than the build-up region. The gel dosimeter dose profile had 3% lower flatness and symmetry measurement at 5 cm depth for different fields compared with that of the Gafchromic™ EBT3 film. During gamma evaluation under 3%/3 mm dose difference/distance-to-agreement standard, the pass rates of the polymer gel dosimeter to the TPS and EBT3 film were both higher than 96%. Given that the gel is tissue equivalent, it did not exhibit the energy dependence problems of radiochromic films. Therefore, the practical use of NIPAM polymer gel dosimeters is enhanced in clinical dose verification. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Preparation of polymer gel dosimeters based on less toxic monomers and gellan gum

    NASA Astrophysics Data System (ADS)

    Hiroki, A.; Sato, Y.; Nagasawa, N.; Ohta, A.; Seito, H.; Yamabayashi, H.; Yamamoto, T.; Taguchi, M.; Tamada, M.; Kojima, T.

    2013-10-01

    New polymer gel dosimeters consisting of 2-hydroxyethyl methacrylate (HEMA), triethylene glycol monoethyl ether monomethacrylate (TGMEMA), polyethylene glycol 400 dimethacrylate (9G), tetrakis (hydroxymethyl) phosphonium chloride as an antioxidant, and gellan gum as a gel matrix were prepared. They were optically analyzed by measuring absorbance to evaluate a dose response. The absorbance of the polymer gel dosimeters that were exposed to 60Co γ-rays increased with increasing dose. The dosimeters comprising HEMA and 9G showed a linear increase in absorbance in the dose range from 0 to 10 Gy. The dose response depended on the 9G concentration. For others comprising HEMA, 9G and TGMEMA, the absorbance of the polymer gel dosimeters drastically increased above a certain dose, and then leveled off up to 10 Gy. The optical variations in these polymer gel dosimeters were also induced by x-irradiation from Cyberknife radiotherapy equipment. Furthermore, the exposed region of the latter polymer gel dosimeter exhibited a thermo-responsive behavior.

  12. Validation of an "Intelligent Mouthguard" Single Event Head Impact Dosimeter.

    PubMed

    Bartsch, Adam; Samorezov, Sergey; Benzel, Edward; Miele, Vincent; Brett, Daniel

    2014-11-01

    Dating to Colonel John Paul Stapp MD in 1975, scientists have desired to measure live human head impacts with accuracy and precision. But no instrument exists to accurately and precisely quantify single head impact events. Our goal is to develop a practical single event head impact dosimeter known as "Intelligent Mouthguard" and quantify its performance on the benchtop, in vitro and in vivo. In the Intelligent Mouthguard hardware, limited gyroscope bandwidth requires an algorithm-based correction as a function of impact duration. After we apply gyroscope correction algorithm, Intelligent Mouthguard results at time of CG linear acceleration peak correlate to the Reference Hybrid III within our tested range of pulse durations and impact acceleration profiles in American football and Boxing in vitro tests: American football, IMG=1.00REF-1.1g, R2=0.99; maximum time of peak XYZ component imprecision 3.6g and 370 rad/s2; maximum time of peak azimuth and elevation imprecision 4.8° and 2.9°; maximum average XYZ component temporal imprecision 3.3g and 390 rad/s2. Boxing, IMG=1.00REF-0.9 g, R2=0.99, R2=0.98; maximum time of peak XYZ component imprecision 3.9 g and 390 rad/s2, maximum time of peak azimuth and elevation imprecision 2.9° and 2.1°; average XYZ component temporal imprecision 4.0 g and 440 rad/s2. In vivo Intelligent Mouthguard true positive head impacts from American football players and amateur boxers have temporal characteristics (first harmonic frequency from 35 Hz to 79 Hz) within our tested benchtop (first harmonic frequency<180 Hz) and in vitro (first harmonic frequency<100 Hz) ranges. Our conclusions apply only to situations where the rigid body assumption is valid, sensor-skull coupling is maintained and the ranges of tested parameters and harmonics fall within the boundaries of harmonics validated in vitro. For these situations, Intelligent Mouthguard qualifies as a single event dosimeter in American football and Boxing.

  13. Characterization of a new radiochromic three-dimensional dosimeter

    SciTech Connect

    Guo, P.Y.; Adamovics, J.A.; Oldham, M.

    2006-05-15

    The development of intensity-modulated radiotherapy (IMRT) has created a clear need for a dosimeter that can accurately and conveniently measure dose distributions in three dimensions to assure treatment quality. PRESAGE{sup TM} is a new three dimensional (3D) dosimetry material consisting of an optically clear polyurethane matrix, containing a leuco dye that exhibits a radiochromic response when exposed to ionizing radiation. A number of potential advantages accrue over other gel dosimeters, including insensitivity to oxygen, radiation induced light absorption contrast rather than scattering contrast, and a solid texture amenable to machining to a variety of shapes and sizes without the requirement of an external container. In this paper, we introduce an efficient method to investigate the basic properties of a 3D dosimetry material that exhibits an optical dose response. The method is applied here to study the key aspects of the optical dose response of PRESAGE{sup TM}: linearity, dose rate dependency, reproducibility, stability, spectral changes in absorption, and temperature effects. PRESAGE{sup TM} was prepared in 1x1x4.5 cm{sup 3} optical cuvettes for convenience and was irradiated by both photon and electron beams to different doses, dose rates, and energies. Longer PRESAGE{sup TM} columns (2 x2x13 cm{sup 3}) were formed without an external container, for measurements of photon and high energy electron depth-dose curves. A linear optical scanning technique was used to detect the depth distribution of radiation induced optical density (OD) change along the PRESAGE{sup TM} columns and cuvettes. Measured depth-OD curves were compared with percent depth dose (PDD). Results indicate that PRESAGE{sup TM} has a linear optical response to radiation dose (with a root mean square error of {approx}1%), little dependency on dose rate ({approx}2%), high intrabatch reproducibility (<2%), and can be stable ({approx}2%) during 2 hours to 2 days post irradiation. Accurate

  14. Characterization of a new radiochromic three-dimensional dosimeter.

    PubMed

    Guo, P Y; Adamovics, J A; Oldham, M

    2006-05-01

    The development of intensity-modulated radiotherapy (IMRT) has created a clear need for a dosimeter that can accurately and conveniently measure dose distributions in three dimensions to assure treatment quality. PRESAGE is a new three dimensional (3D) dosimetry material consisting of an optically clear polyurethane matrix, containing a leuco dye that exhibits a radiochromic response when exposed to ionizing radiation. A number of potential advantages accrue over other gel dosimeters, including insensitivity to oxygen, radiation induced light absorption contrast rather than scattering contrast, and a solid texture amenable to machining to a variety of shapes and sizes without the requirement of an external container. In this paper, we introduce an efficient method to investigate the basic properties of a 3D dosimetry material that exhibits an optical dose response. The method is applied here to study the key aspects of the optical dose response of PRESAGE: linearity, dose rate dependency, reproducibility, stability, spectral changes in absorption, and temperature effects. PRESAGE was prepared in 1 x 1 x 4.5 cm3 optical cuvettes for convenience and was irradiated by both photon and electron beams to different doses, dose rates, and energies. Longer PRESAGE columns (2 x 2 x 13 cm3) were formed without an external container, for measurements of photon and high energy electron depth-dose curves. A linear optical scanning technique was used to detect the depth distribution of radiation induced optical density (OD) change along the PRESAGE columns and cuvettes. Measured depth-OD curves were compared with percent depth dose (PDD). Results indicate that PRESAGE has a linear optical response to radiation dose (with a root mean square error of -1%), little dependency on dose rate (-2%), high intrabatch reproducibility (< 2%), and can be stable (-2%) during 2 hours to 2 days post irradiation. Accurate PRESAGE dosimetry requires temperature control within 1 degrees C

  15. An investigation of a PRESAGE® in vivo dosimeter for brachytherapy

    NASA Astrophysics Data System (ADS)

    Vidovic, A. K.; Juang, T.; Meltsner, S.; Adamovics, J.; Chino, J.; Steffey, B.; Craciunescu, O.; Oldham, M.

    2014-07-01

    Determining accurate in vivo dosimetry in brachytherapy treatment with high dose gradients is challenging. Here we introduce, investigate, and characterize a novel in vivo dosimeter and readout technique with the potential to address this problem. A cylindrical (4 mm × 20 mm) tissue equivalent radiochromic dosimeter PRESAGE® in vivo (PRESAGE®-IV) is investigated. Two readout methods of the radiation induced change in optical density (OD) were investigated: (i) volume-averaged readout by spectrophotometer, and (ii) a line profile readout by 2D projection imaging utilizing a high-resolution (50 micron) telecentric optical system. Method (i) is considered the gold standard when applied to PRESAGE® in optical cuvettes. The feasibility of both methods was evaluated by comparison to standard measurements on PRESAGE® in optical cuvettes via spectrophotometer. An end-to-end feasibility study was performed by a side-by-side comparison with TLDs in an 192Ir HDR delivery. 7 and 8 Gy was delivered to PRESAGE®-IV and TLDs attached to the surface of a vaginal cylinder. Known geometry enabled direct comparison of measured dose with a commissioned treatment planning system. A high-resolution readout study under a steep dose gradient region showed 98.9% (5%/1 mm) agreement between PRESAGE®-IV and Gafchromic® EBT2 Film. Spectrometer measurements exhibited a linear dose response between 0-15 Gy with sensitivity of 0.0133 ± 0.0007 ΔOD/(Gy ṡ cm) at the 95% confidence interval. Method (ii) yielded a linear response with sensitivity of 0.0132 ± 0.0006 (ΔOD/Gy), within 2% of method (i). Method (i) has poor spatial resolution due to volume averaging. Method (ii) has higher resolution (˜1 mm) without loss of sensitivity or increased noise. Both readout methods are shown to be feasible. The end-to-end comparison revealed a 2.5% agreement between PRESAGE®-IV and treatment plan in regions of uniform high dose. PRESAGE®-IV shows promise for in vivo dose verification

  16. Development of a wavelength-separated type scintillator with optical fiber (SOF) dosimeter to compensate for the Cerenkov radiation effect

    PubMed Central

    Ishikawa, Masayori; Nagase, Naomi; Matsuura, Taeko; Hiratsuka, Junichi; Suzuki, Ryusuke; Miyamoto, Naoki; Sutherland, Kenneth Lee; Fujita, Katsuhisa; Shirato, Hiroki

    2015-01-01

    The scintillator with optical fiber (SOF) dosimeter consists of a miniature scintillator mounted on the tip of an optical fiber. The scintillator of the current SOF dosimeter is a 1-mm diameter hemisphere. For a scintillation dosimeter coupled with an optical fiber, measurement accuracy is influenced by signals due to Cerenkov radiation in the optical fiber. We have implemented a spectral filtering technique for compensating for the Cerenkov radiation effect specifically for our plastic scintillator-based dosimeter, using a wavelength-separated counting method. A dichroic mirror was used for separating input light signals. Individual signal counting was performed for high- and low-wavelength light signals. To confirm the accuracy, measurements with various amounts of Cerenkov radiation were performed by changing the incident direction while keeping the Ir-192 source-to-dosimeter distance constant, resulting in a fluctuation of <5%. Optical fiber bending was also addressed; no bending effect was observed for our wavelength-separated SOF dosimeter. PMID:25618136

  17. Development of a wavelength-separated type scintillator with optical fiber (SOF) dosimeter to compensate for the Cerenkov radiation effect.

    PubMed

    Ishikawa, Masayori; Nagase, Naomi; Matsuura, Taeko; Hiratsuka, Junichi; Suzuki, Ryusuke; Miyamoto, Naoki; Sutherland, Kenneth Lee; Fujita, Katsuhisa; Shirato, Hiroki

    2015-03-01

    The scintillator with optical fiber (SOF) dosimeter consists of a miniature scintillator mounted on the tip of an optical fiber. The scintillator of the current SOF dosimeter is a 1-mm diameter hemisphere. For a scintillation dosimeter coupled with an optical fiber, measurement accuracy is influenced by signals due to Cerenkov radiation in the optical fiber. We have implemented a spectral filtering technique for compensating for the Cerenkov radiation effect specifically for our plastic scintillator-based dosimeter, using a wavelength-separated counting method. A dichroic mirror was used for separating input light signals. Individual signal counting was performed for high- and low-wavelength light signals. To confirm the accuracy, measurements with various amounts of Cerenkov radiation were performed by changing the incident direction while keeping the Ir-192 source-to-dosimeter distance constant, resulting in a fluctuation of <5%. Optical fiber bending was also addressed; no bending effect was observed for our wavelength-separated SOF dosimeter.

  18. Feasibility Study of Glass Dosimeter for In Vivo Measurement: Dosimetric Characterization and Clinical Application in Proton Beams

    SciTech Connect

    Rah, Jeong-Eun; Oh, Do Hoon; Kim, Jong Won; Kim, Dae-Hyun; Suh, Tae-Suk; Ji, Young Hoon; Shin, Dongho; Lee, Se Byeong; Kim, Dae Yong; Park, Sung Yong

    2012-10-01

    Purpose: To evaluate the suitability of the GD-301 glass dosimeter for in vivo dose verification in proton therapy. Methods and Materials: The glass dosimeter was analyzed for its dosimetrics characteristic in proton beam. Dosimeters were calibrated in a water phantom using a stairlike holder specially designed for this study. To determine the accuracy of the glass dosimeter in proton dose measurements, we compared the glass dosimeter and thermoluminescent dosimeter (TLD) dose measurements using a cylindrical phantom. We investigated the feasibility of the glass dosimeter for the measurement of dose distributions near the superficial region for proton therapy plans with a varying separation between the target volume and the surface of 6 patients. Results and Discussion: Uniformity was within 1.5%. The dose-response has good linearity. Dose-rate, fading, and energy dependence were found to be within 3%. The beam profile measured using the glass dosimeter was in good agreement with the profile obtained from the ionization chamber. Depth-dose distributions in nonmodulated and modulated proton beams obtained with the glass dosimeter were estimated to be within 3%, which was lower than those with the ionization chamber. In the phantom study, the difference of isocenter dose between the delivery dose calculated by the treatment planning system and that measured by the glass dosimeter was within 5%. With in vivo dosimetry, the calculated surface doses overestimated measurements by 4%-16% using glass dosimeter and TLD. Conclusion: It is recommended that bolus be added for these clinical cases. We also believe that the glass dosimeter has considerable potential for use with in vivo patient proton dosimetry.

  19. Spectral discrimination of Cerenkov radiation in scintillating dosimeters.

    PubMed

    Frelin, A M; Fontbonne, J M; Ban, G; Colin, J; Labalme, M; Batalla, A; Isambert, A; Vela, A; Leroux, T

    2005-09-01

    Radiation therapy accelerators require highly accurate dose deposition and the output must be monitored frequently and regularly. Ionization chambers are the primary tool for this control, but their size, their high voltage needed, and the correction needed for electrons make them unsuitable for use during patient treatment. We have developed a small (1-mm-diam and 1-mm-long active part), flexible, and water-equivalent dosimeter. It is suitable for photon and electron beams without corrections, and performs on line dose measurements. This detector is based on only one scintillating fiber and a CCD camera. A new signal processing is used to remove the effect of Cerenkov radiation background, which only requires a preliminary calibration. Central-axis depth-dose distribution comparisons have been achieved with standard ionization chambers, over a range from 8 to 25 MV photons and from 6 to 21 MeV electrons in order to validate this calibration. Results show a very good agreement, with less than 1% difference between the two detectors.

  20. A small active dosimeter for applications in space

    NASA Astrophysics Data System (ADS)

    Ritter, Birgit; Maršálek, Karel; Berger, Thomas; Burmeister, Sönke; Reitz, Günther; Heber, Bernd

    2014-06-01

    The radiation field in low Earth orbits (LEO) differs significantly from the radiation environment on Earth's surface. Exposures are by far higher and pose an additional health risk for astronauts. Continuous monitoring is therefore a necessary task in the frame of radiation protection measures. A small battery-driven active dosimeter telescope based on silicon detectors meeting the requirements for LEO applications has been developed. The instrument, the Mobile Dosimetric Telescope (MDT), is designed to measure the absorbed dose rate and the linear energy transfer (LET) spectra. From the latter the mean quality factor of the radiation field can be derived and hence an estimate of the dose equivalent as a measure of the exposure. The calibration of the device is done using radioactive isotopes and heavy ions. Fragmentation products of heavy ions are used to show the ability of the MDT to reliably detect energy depositions from high energetic nuclei. Radiation measurements inside aircraft during long distance flights, serving as field tests of the instrument, prove the good performance of the instrument.

  1. Development and characterization of a DNA solar dosimeter.

    PubMed

    Ishigaki, Y; Takayama, A; Yamashita, S; Nikaido, O

    1999-06-01

    In this paper, we report the development and characterization of a solar ultraviolet (UV) dosimetry system that can be used as a film badge for radiation monitoring. DNA molecules are coated on a thin nylon membrane as a UV dosimeter. The membrane is sealed in a polyethylene filter envelope with silica gel to keep the humidity low. After exposure to UV or solar light, induced DNA damage is measured by an immunochemical reaction. The intensity of color developed during the immunological reaction can be correlated linearly with the irradiated UV dose delivered by an Oriel solar simulator within a limited dose range. We observe no effects of temperature on the level of damage induction. The membrane is proficient for measuring DNA damage for more than 21 days when stored at either 37 or 4 degrees C. The induced damage remains stable on the membrane for at least 22 days at both 37 and 4 degrees C. In addition to these indoor experiments, we report measurements of solar UV dose in outdoor experiments.

  2. Developments in production of silica-based thermoluminescence dosimeters

    NASA Astrophysics Data System (ADS)

    Bradley, D. A.; Siti Shafiqah, A. S.; Siti Rozaila, Z.; Sabtu, Siti Norbaini; Abdul Sani, S. F.; Alanazi, Abdulaziz H.; Jafari, S. M.; Amouzad Mahdiraji, G.; Mahamd Adikan, F. R.; Maah, M. J.; Nisbet, A. N.; Tamchek, N.; Abdul Rashid, H. A.; Alkhorayef, M.; Alzimami, K.

    2017-08-01

    This work addresses purpose-made thermoluminescence dosimeters (TLD) based on doped silica fibres and sol-gel nanoparticles, produced via Modified Chemical Vapour Deposition (MCVD) and wet chemistry techniques respectively. These seek to improve upon the versatility offered by conventional phosphor-based TLD forms such as that of doped LiF. Fabrication and irradiation-dependent factors are seen to produce defects of differing origin, influencing the luminescence of the media. In coming to a close, we illustrate the utility of Ge-doped silica media for ionizing radiation dosimetry, first showing results from gamma-irradiated Ag-decorated nanoparticles, in the particular instance pointing to an extended dynamic range of dose. For the fibres, at radiotherapy dose levels, we show high spatial resolution (0.1 mm) depth-dose results for proton irradiations. For novel microstructured fibres (photonic crystal fibres, PCFs) we show first results from a study of undisturbed and technologically modified naturally occurring radioactivity environments, measuring doses of some 10 s of μGy over a period of several months.

  3. Study of Fricke gel dosimeter response for different gel quality

    NASA Astrophysics Data System (ADS)

    Cavinato, C. C.; Campos, L. L.

    2010-11-01

    The Fricke xylenol gel (FXG) dosimeter has been studied for application in radiotherapy because it is capable of to measure the spatial distribution of radiation doses. The dosimetry is based on the oxidation of ferrous (Fe2+) to ferric (Fe3+) ions radiation induced, related to the radiation dose. The gel material usually employed is the 300 Bloom gelatin, which is imported and very expensive in Brazil. Aiming to analyze the viability of to use a locally produced and low cost gel material, in this work the spectrophotometric responses of FXG solutions prepared using 270 Bloom gelatin commercially available and 300 Bloom gelatin imported were compared. The absorption spectra of solutions prepared with 5% by weight 270 and 300 Bloom gelatins non-irradiated and irradiated with 60Co gamma radiation in the dose range between 0.5 and 100 Gy were analysed, the dose-response curves were evaluated and the useful dose range was established. The obtained results indicate that the FXG solution prepared with 270 Bloom gelatin presents good performance, similar to that presented by the FXG solution prepared with 300 Bloom gelatin and its use can be recommended owing to the low cost and the availability in local market.

  4. DNA as a solar dosimeter in the ocean

    SciTech Connect

    Regan, J.D.; Carrier, W.L. ); Gucinski, H. ); Olla, B.L. ); Wicklund, R.I. )

    1990-01-09

    Increased solar UV[B] in the ocean may be one of the results of atmospheric ozone depletion and may cause deleterious effects on marine organisms. The primary lesion induced by UV(B) in biological systems in DNA damage. While physical measurements of solar UV(B) penetration into the sea have been made, depth and magnitude of actual DNA damage has yet to be demonstrated. We have quantitated UV(B)-induced photoproducts (cyclobutane pyrimidine dimers) in DNA molecules exposed to solar UV at the surface and at various depths in clear, tropical oceanic waters off Lee Stocking Island, Bahamas. [sup 14]C-thymidine-labeled DNA was placed in quartz cuvettes polished on all four sides and suspended horizontally in special holders at selected depths for exposures of up to five days. Simultaneous measurements of light were made with an underwater photometer. Following exposures, DNA samples were transported to the laboratory and the pyrimidine dimers induced were quantitated using a radiochromatographic assay. The attenuation of the yield of dimer was approximately linear between 0 and 1.0 m. However, at 3.0 m, the yield was considerably higher than predicted by the earlier portion of the curve. Preliminary laboratory experiments with DNA in seawater tanks using a solar simulating light source markedly underestimated the yield of dimers found under field conditions. Implications of these results and applications of this biomolecular dosimeter system will be discussed.

  5. Dose measurements in intraoral radiography using thermoluminescent dosimeters

    NASA Astrophysics Data System (ADS)

    Azorín, C.; Azorín, J.; Aguirre, F.; Rivera, T.

    2015-01-01

    The use of X-ray in medicine demands to expose the patient and the professional to the lowest radiation doses available in agreement with ALARA philosophy. The reference level for intraoral dental radiography is 7 mGy and, in Mexico, a number of examinations of this type are performed annually. It is considered that approximately 25% of all the X-rays examinations carried out in our country correspond to intraoral radiographies. In other hand, most of the intraoral X-ray equipment correspond to conventional radiological systems using film, which are developed as much manual as automatically. In this work the results of determining the doses received by the patients in intraoral radiological examinations made with different radiological systems using LiF:Mg,Cu,P+PTFE thermoluminescent dosimeters are presented. In some conventional radiological systems using film, when films are developed manual or automatically, incident kerma up to 10.61 ± 0.74 mGv were determined. These values exceed that reference level suggested by the IAEA and in the Mexican standards for intraoral examinations.

  6. Entrance surface dose measurements using a small OSL dosimeter with a computed tomography scanner having 320 rows of detectors.

    PubMed

    Takegami, Kazuki; Hayashi, Hiroaki; Yamada, Kenji; Mihara, Yoshiki; Kimoto, Natsumi; Kanazawa, Yuki; Higashino, Kousaku; Yamashita, Kazuta; Hayashi, Fumio; Okazaki, Tohru; Hashizume, Takuya; Kobayashi, Ikuo

    2017-03-01

    Entrance surface dose (ESD) measurements are important in X-ray computed tomography (CT) for examination, but in clinical settings it is difficult to measure ESDs because of a lack of suitable dosimeters. We focus on the capability of a small optically stimulated luminescence (OSL) dosimeter. The aim of this study is to propose a practical method for using an OSL dosimeter to measure the ESD when performing a CT examination. The small OSL dosimeter has an outer width of 10 mm; it is assumed that a partial dose may be measured because the slice thickness and helical pitch can be set to various values. To verify our method, we used a CT scanner having 320 rows of detectors and checked the consistencies of the ESDs measured using OSL dosimeters by comparing them with those measured using Gafchromic™ films. The films were calibrated using an ionization chamber on the basis of half-value layer estimation. On the other hand, the OSL dosimeter was appropriately calibrated using a practical calibration curve previously proposed by our group. The ESDs measured using the OSL dosimeters were in good agreement with the reference ESDs from the Gafchromic™ films. Using these data, we also estimated the uncertainty of ESDs measured with small OSL dosimeters. We concluded that a small OSL dosimeter can be considered suitable for measuring the ESD with an uncertainty of 30 % during CT examinations in which pitch factors below 1.000 are applied.

  7. Unfolding neutron spectra from simulated response of thermoluminescence dosimeters inside a polyethylene sphere using GRNN neural network

    NASA Astrophysics Data System (ADS)

    Lotfalizadeh, F.; Faghihi, R.; Bahadorzadeh, B.; Sina, S.

    2017-07-01

    Neutron spectrometry using a single-sphere containing dosimeters has been developed recently, as an effective replacement for Bonner sphere spectrometry. The aim of this study is unfolding the neutron energy spectra using GRNN artificial neural network, from the response of thermoluminescence dosimeters, TLDs, located inside a polyethylene sphere. The spectrometer was simulated using MCNP5. TLD-600 and TLD-700 dosimeters were simulated at different positions in all directions. Then the GRNN was used for neutron spectra prediction, using the TLDs' readings. Comparison of spectra predicted by the network with the real spectra, show that the single-sphere dosimeter is an effective instrument in unfolding neutron spectra.

  8. Study of a non-diffusing radiochromic gel dosimeter for 3D radiation dose imaging

    NASA Astrophysics Data System (ADS)

    Marsden, Craig Michael

    2000-12-01

    This thesis investigates the potential of a new radiation gel dosimeter, based on nitro-blue tetrazolium (NBTZ) suspended in a gelatin mold. Unlike all Fricke based gel dosimeters this dosimeter does not suffer from diffusive loss of image stability. Images are obtained by an optical tomography method. Nitro blue tetrazolium is a common biological indicator that when irradiated in an aqueous medium undergoes reduction to a highly colored formazan, which has an absorbance maximum at 525nm. Tetrazolium is water soluble while the formazan product is insoluble. The formazan product sticks to the gelatin matrix and the dose image is maintained for three months. Methods to maximize the sensitivity of the system were evaluated. It was found that a chemical detergent, Triton X-100, in combination with sodium formate, increased the dosimeter sensitivity significantly. An initial G-value of formazan production for a dosimeter composed of 1mM NBTZ, gelatin, and water was on the order of 0.2. The addition of Triton and formate produced a G-value in excess of 5.0. The effects of NBTZ, triton, formate, and gel concentration were all investigated. All the gels provided linear dose vs. absorbance plots for doses from 0 to >100 Gy. It was determined that gel concentration had minimal if any effect on sensitivity. Sensitivity increased slightly with increasing NBTZ concentration. Triton and formate individually and together provided moderate to large increases in dosimeter sensitivity. The dosimeter described in this work can provide stable 3D radiation dose images for all modalities of radiation therapy equipment. Methods to increase sensitivity are developed and discussed.

  9. SU-E-T-368: Effect of a Strong Magnetic Field On Select Radiation Dosimeters

    SciTech Connect

    Mathis, M; Wen, Z; Tailor, R; Sawakuchi, G; Flint, D; Beddar, S; Ibbott, G

    2014-06-01

    Purpose: To determine the effect of a strong magnetic field on TLD-100, OSLD (Al{sub 2}O{sub 2}:C), and PRESAGE dosimetry devices. This study will help to determine which types of dosimeters can be used for quality assurance and in-vivo dosimetry measurements in a magnetic resonance imaginglinear accelerator (MRI-linac) system. Methods: The dosimeters were separated into two categories which were either exposed or not exposed to a strong magnetic field. In each category a set of dosimeters was irradiated with 0, 2, or 6 Gy. To expose the dosimeters to a magnetic field the samples in that category were place in a Bruker small animal magnetic resonance scanner at a field strength slightly greater than 2.5 T for at least 1 hour preirradiation and at least 1 hour post-irradiation. Irradiations were performed with a 6 MV x-ray beam from a Varian TrueBeam linac with 10×10 cm{sup 2} field at a 600 MU/min dose rate. The samples that received no radiation dose were used as control detectors. Results: The readouts of the dosimeters which were not exposed to a strong magnetic field were compared with the measurements of the dosimetry devices which were exposed to a magnetic field. No significant differences (less than 2% difference) in the performance of TLD, OSLD, or PRESAGE dosimeters due to exposure to a strong magnetic field were observed. Conclusion: Exposure to a strong magnetic field before and after irradiation does not appear to change the dosimetric properties of TLD, OSLD, or PRESAGE which indicates that these dosimeters have potential for use in quality assurance and in-vivo dosimetry in a MRI-linac. We plan to further test the effect of magnetic fields on these devices by irradiating them in the presence of a magnetic fields similar to those produced by a MRI-linac system. Elekta-MD Anderson Cancer Center Research Agreement.

  10. TH-C-19A-05: Evaluation of a New Reusable 3D Dosimeter

    SciTech Connect

    Juang, T; Adamovics, J; Oldham, M

    2014-06-15

    Purpose: PRESAGE is a radiochromic plastic which has demonstrated strong potential for high resolution single-use 3D dosimetry. This study evaluates a new PRESAGE formulation (Presage-RU) in which the radiochromic response is reversible (the dosimeter optically clears after irradiation), enabling the potential for reusability. Methods: Presage-RU dose response and optical-clearing rates were evaluated in both small volume dosimeters (1×1×4.5cm) and a larger cylindrical dosimeter (8cm diameter, 4.5cm length). All dosimeters were allowed to fully optically clear in dark, room temperature conditions between irradiations. Dose response was determined by irradiating small volume samples from 0–8.0Gy and measuring change in optical density. The cylindrical dosimeter was irradiated with a simple 4-field box plan (parallel opposed pairs of 4cm×4cm AP-PA beams and 2cm×4cm lateral beams) to 20Gy. High resolution 3D dosimetry was achieved utilizing optical-CT readout. Readings were tracked up to 14 days to characterize optical clearing. Results: Initial irradiation yielded a response of 0.0119△OD/(Gy*cm) while two subsequent reirradiations yielded a lower but consistent response of 0.0087△OD/(Gy*cm). Strong linearity of dose response was observed for all irradiations. In the large cylindrical dosimeter, the integral dose within the high dose region exhibited an exponential decay in signal over time (halflife= 23.9 hours), with the dosimeter effectively cleared (0.04% of the initial signal) after 10 days. Subsequent irradiation resulted in 19.5% lower initial signal but demonstrated that the exponential clearing rate remained consistent. Results of additional subsequent irradiations will also be presented. Conclusion: This work introduces a new re-usable radiochromic dosimeter (Presage-RU) compatible with high resolution (sub-millimeter) 3D dosimetry. Sensitivity of the initial radiation was observed to be slightly higher than subsequent irradiations, but the

  11. Laboratory evaluation of stain-length passive dosimeters for monitoring of vinyl chloride and ethylene oxide

    SciTech Connect

    Gonzalez, L.A.; Sefton, M.V.

    1985-10-01

    The effects of vapor concentration in the range of 1.2 to 5.1 ppm (vinyl chloride) and 8.3 to 29.1 ppm (ethylene oxide) on the response of new stain-length passive dosimeters were evaluated separately in a dynamic exposure chamber. The vinyl chloride dosimeter was prepared with a permanganate impregnated blend of Chromosorb W and silica gel, while a silica gel-coated plastic strip (TLC plate) impregnated with dichromate was used to detect ethylene oxide. The use of a TLC plate as the inert support allowed us to reduce the amount of reagent loaded per length of tube, thus significantly enhancing in the sensitivity of the unit, which was necessary for accurately detecting ethylene oxide at these low concentrations. At the vinyl chloride exposure of 8 ppm-hrs the length of stain was 0.76 cm and the 95% confidence interval about this point was +/- 1.4 ppm-hrs (18%). For the ethylene oxide dosimeter the length of stain at the exposure of 80 ppm-hrs was 0.90 cm and the 95% confidence interval about this point was +/- 16 ppm-hrs (20%). The ethylene oxide dosimeter response was not affected by relative humidity in the range of 28 to 90%. The use of a TLC plate as the inert support of the colorimetric reagent has proven to be an excellent means of improving the sensitivity of these stain-length passive dosimeters.

  12. Estimation of biologically damaging UV levels in marine surface waters with DNA and viral dosimeters.

    PubMed

    Wilhelm, Steven W; Jeffrey, Wade H; Suttle, Curtis A; Mitchell, David L

    2002-09-01

    We have surveyed the biologically harmful radiation penetrating the water column along a transect in the western Gulf of Mexico using dosimeters consisting of intact viruses or naked calf-thymus DNA (ctDNA). The indigenous marine bacteriophage PWH3a-P1, which lytically infects the heterotrophic bacterium Vibrio natriegens (strain PWH3a), displayed decay rates for infectivity approaching 1.0 h(-1) in surface waters when deployed in a seawater-based dosimeter. The accumulation of pyrimidine dimers in ctDNA dosimeters provided a strong correlation to these results, with pyrimidine dimers representing more than 0.3% (up to ca 3800 dimers Mb(-1) DNA) of the total DNA in dosimeters exposed to sea surface levels of solar radiation. The results demonstrate a strong correlation between the dimer formation in the DNA dosimeters, the decay rates of viral infectivity and the penetration of UVB radiation into the water column. The decay of viral infectivity attenuated with depth in a manner similar to the decay of solar radiation and was still significant at 10 m in offshore oligotrophic water and at dimer frequencies less than 0.1% (ca 200-300 dimers Mb(-1) DNA).

  13. Biological and physical dosimeters for monitoring solar UV-B light.

    PubMed

    Furusawa, Y; Suzuki, K; Sasaki, M

    1990-06-01

    A biological dosimetry system for measuring solar UV-B light was established using bacteriophage T1 with E. coli Bs-1 as the host cell. Also a new physical UV-B dosimeter was developed which can specifically detect the UV spectral region related to inactivation of phage T1. Phage T1 is very stable in liquid suspension and it has adequate sensitivity to measure the intensity of solar UV-B. In addition, the survival of phage T1 responded linearly to UV fluences when plotted semi-logarithmic ally. Thus T1 seemed to have characteristic features making it suitable material as a biological dosimeter for sunlight. Outdoor experiments throughout one year showed that the mean amount of solar UV light in summer was about 6 fold larger than that in winter at Isehara (139.5 degrees E, 35.5 degrees N), Japan. A novel physical dosimeter which responds faithfully to UV-B light under atmospheric conditions on the ground was developed as well. The spectral response was very close to that of biological materials. Readings of this UV-B dosimeter could be converted into the efficiency of sunlight upon biological materials. This instrument is compact; it can also be used as an erythemal dosimeter.

  14. Cerium nanoparticle effect on sensitivity of Fricke gel dosimeter: Initial investigation

    NASA Astrophysics Data System (ADS)

    Ebenezer Suman Babu, S.; Peace Balasingh, S. Timothy; Benedicta Pearlin, R.; Rabi Raja Singh, I.; Ravindran, B. Paul

    2017-05-01

    Fricke gel dosimeters (FXGs) have been the preferred dosimeters because of its ease in preparation and water and tissue equivalency. Visible changes happen three dimensionally in the dosimeter as the ferrous (Fe2+) ions change into ferric (Fe3+) ions upon irradiation and the measure of this change can be correlated to the dose absorbed. Nanoparticles are promising entities that can improve the sensitivity of the gel dosimeter. Cerium Oxide nanoparticle was investigated for possible enhancement of absorbed dose in the FXG. Various concentrations of the nanoparticle based gel dosimeters were prepared and irradiated for a clinical dose range of 0-3 Gy in a telegamma unit. The optimal concentration of 0.1 mM nanoparticle incorporated in the FXG enhances the radiation sensitivity of the unmodified FXG taken as reference without modifying the background absorbance prior to irradiation. The gel recipe consisted of 5% (wt) gelatin, 50 mM Sulphuric acid, 0.05 mM Xylenol Orange, 0.5 mM Ferrous Ammonium Sulphate and 0.1 mM Cerium (IV) Oxide nanoparticle (< 25 nm particle size) and triple distilled water. The FXGs with nanoparticle showed linear dose response in the dose range tested.

  15. Undoped and doped poly(tetraphenylbenzidine) as sensitive material for an impedimetric nitrogen dioxide gas dosimeter

    SciTech Connect

    Marr, I.; Moos, R.; Neumann, K.; Thelakkat, M.

    2014-09-29

    This article presents a nitrogen dioxide (NO{sub 2}) detecting gas dosimeter based on poly(tetraphenylbenzidine) poly(TPD) as nitrogen oxide (NO{sub x}) sensitive layer. Gas dosimeters are suitable devices to determine reliably low levels of analytes over a long period of time. During NO{sub x} exposure, the analyte molecules are accumulated irreversibly in the sensing layer of the dosimeter enhancing the conductivity of the hole conducting poly(TPD), which can be measured by impedance spectroscopy. Due to their possibility for low cost production by simple printing techniques and very good physical, photochemical, and electrochemical properties, poly(TPD)s are suitable for application in gas dosimeters operated at room temperature. We studied the effect of doping with a Co(III)-complex in combination with a conducting salt on the dosimeter behavior. Compared to the undoped material, a strong influence of the doping can be observed: the conductivity of the sensing material increases significantly, the noise of the signal decreases and an unwanted recovery of the sensor signal can be prevented, leading to a NO{sub x} detection limit <10 ppm.

  16. Chemically tuned linear energy transfer dependent quenching in a deformable, radiochromic 3D dosimeter

    NASA Astrophysics Data System (ADS)

    Høye, Ellen Marie; Skyt, Peter S.; Balling, Peter; Muren, Ludvig P.; Taasti, Vicki T.; Swakoń, Jan; Mierzwińska, Gabriela; Rydygier, Marzena; Bassler, Niels; Petersen, Jørgen B. B.

    2017-02-01

    Most solid-state detectors, including 3D dosimeters, show lower signal in the Bragg peak than expected, a process termed quenching. The purpose of this study was to investigate how variation in chemical composition of a recently developed radiochromic, silicone-based 3D dosimeter influences the observed quenching in proton beams. The dependency of dose response on linear energy transfer, as calculated through Monte Carlo simulations of the dosimeter, was investigated in 60 MeV proton beams. We found that the amount of quenching varied with the chemical composition: peak-to-plateau ratios (1 cm into the plateau) ranged from 2.2 to 3.4, compared to 4.3 using an ionization chamber. The dose response, and thereby the quenching, was predominantly influenced by the curing agent concentration, which determined the dosimeter’s deformation properties. The dose response was found to be linear at all depths. All chemical compositions of the dosimeter showed dose-rate dependency; however this was not dependent on the linear energy transfer. Track-structure theory was used to explain the observed quenching effects. In conclusion, this study shows that the silicone-based dosimeter has potential for use in measuring 3D-dose-distributions from proton beams.

  17. Calibration coefficients of dosimeters used in mammography for various target/filter combinations.

    PubMed

    Sekimoto, Michiharu; Katoh, Yoh; Katoh, Tsuguhisa

    2015-11-08

    A wide variety of existing combinations of target and filter materials (target/filter combinations) are used in mammography equipment. The patient dose depends on the X-ray quality that is derived from the target/filter combination, and a calibration of the dosimeter that is used in the measurement that corresponds to the specific target/filter combination is necessary. However, dosimeters in mammography are generally calibrated with reference to the X-ray quality of Mo/Mo or W/Al combinations, and it is unclear whether or not the X-ray quality that is derived from other target/filter combinations will affect the calibration coefficients. In this paper, the calibration coefficients of different dosimeters were evaluated for target/filter combinations. For an ionization chamber-type dosimeter, good energy dependence was found and the effect of the target/filter combination was small. However, for a semiconductor dosimeter, a large energy dependence was found, and different calibration coefficients that depended on the target/filter combination used were required.

  18. Photofission Analysis for Fissile Dosimeters Dedicated to Reactor Pressure Vessel Surveillance

    NASA Astrophysics Data System (ADS)

    Bourganel, Stéphane; Faucher, Margaux; Thiollay, Nicolas

    2016-02-01

    Fissile dosimeters are commonly used in reactor pressure vessel surveillance programs. In this paper, the photofission contribution is analyzed for in-vessel 237Np and 238U fissile dosimeters in French PWR. The aim is to reassess this contribution using recent tools (the TRIPOLI-4 Monte Carlo code) and latest nuclear data (JEFF3.1.1 and ENDF/B-VII nuclear libraries). To be as exhaustive as possible, this study is carried out for different configurations of fissile dosimeters, irradiated inside different kinds of PWR: 900 MWe, 1300 MWe, and 1450 MWe. Calculation of photofission rate in dosimeters does not present a major problem using the TRIPOLI-4® Monte Carlo code and the coupled neutron-photon simulation mode. However, preliminary studies were necessary to identify the origin of photons responsible of photofissions in dosimeters in relation to the photofission threshold reaction (around 5 MeV). It appears that the main contribution of high enough energy photons generating photofissions is the neutron inelastic scattering in stainless steel reactor structures. By contrast, 137Cs activity calculation is not an easy task since photofission yield data are known with high uncertainty.

  19. FlexyDos3D: a deformable anthropomorphic 3D radiation dosimeter: radiation properties

    NASA Astrophysics Data System (ADS)

    De Deene, Y.; Skyt, P. S.; Hil, R.; Booth, J. T.

    2015-02-01

    Three dimensional radiation dosimetry has received growing interest with the implementation of highly conformal radiotherapy treatments. The radiotherapy community faces new challenges with the commissioning of image guided and image gated radiotherapy treatments (IGRT) and deformable image registration software. A new three dimensional anthropomorphically shaped flexible dosimeter, further called ‘FlexyDos3D’, has been constructed and a new fast optical scanning method has been implemented that enables scanning of irregular shaped dosimeters. The FlexyDos3D phantom can be actuated and deformed during the actual treatment. FlexyDos3D offers the additional advantage that it is easy to fabricate, is non-toxic and can be molded in an arbitrary shape with high geometrical precision. The dosimeter formulation has been optimized in terms of dose sensitivity. The influence of the casting material and oxygen concentration has also been investigated. The radiophysical properties of this new dosimeter are discussed including stability, spatial integrity, temperature dependence of the dosimeter during radiation, readout and storage, dose rate dependence and tissue equivalence. The first authors Y De Deene and P S Skyt made an equivalent contribution to the experimental work presented in this paper.

  20. Single and multichannel scintillating fiber dosimeter for radiotherapic beams with SiPM readout

    NASA Astrophysics Data System (ADS)

    Berra, A.; Ferri, A.; Novati, C.; Ostinelli, A.; Paternoster, G.; Piemonte, C.; Prest, M.; Vallazza, E.

    2016-12-01

    The treatment of many neoplastic diseases requires the use of radiotherapy, which consists in the irradiation of the tumor, identified as the target volume, with ionizing radiations generated both by administered radiopharmaceuticals or by linear particle accelerators (LINACs). The radiotherapy beam delivered to the patient must be regularly checked to assure the best tumor control probability: this task is performed with dosimeters, i.e. devices able to provide a measurement of the dose deposited in their sensitive volume. This paper describes the development of two scintillator dosimeter prototypes for radiotherapic applications based on plastic scintillating fibers read out by high dynamic range Silicon PhotoMultipliers. The first dosimeter, consisting of a single-channel prototype with a pair of optical fibers, a scintillating and a white one, read out by two SiPMs, has been fully characterized and led to the development of a second multi-channel dosimeter based on an array of scintillating fibers: this device represents the first step towards the assembly of a "one-shot" device, capable to perform some of the daily quality controls in a few seconds. The dosimeters characterization was performed with a Varian Clinac iX linear accelerator at the Radiotherapy Department of the St. Anna Hospital in Como (IT).

  1. Dose rate dependence for different dosimeters and detectors: TLD, OSL, EBT films, and diamond detectors

    SciTech Connect

    Karsch, L.; Beyreuther, E.; Burris-Mog, T.; Kraft, S.; Richter, C.; Zeil, K.; Pawelke, J.

    2012-05-15

    Purpose: The use of laser accelerators in radiation therapy can perhaps increase the low number of proton and ion therapy facilities in some years due to the low investment costs and small size. The laser-based acceleration technology leads to a very high peak dose rate of about 10{sup 11} Gy/s. A first dosimetric task is the evaluation of dose rate dependence of clinical dosimeters and other detectors. Methods: The measurements were done at ELBE, a superconductive linear electron accelerator which generates electron pulses with 5 ps length at 20 MeV. The different dose rates are reached by adjusting the number of electrons in one beam pulse. Three clinical dosimeters (TLD, OSL, and EBT radiochromic films) were irradiated with four different dose rates and nearly the same dose. A faraday cup, an integrating current transformer, and an ionization chamber were used to control the particle flux on the dosimeters. Furthermore two diamond detectors were tested. Results: The dosimeters are dose rate independent up to 410{sup 9} Gy/s within 2% (OSL and TLD) and up to 1510{sup 9} Gy/s within 5% (EBT films). The diamond detectors show strong dose rate dependence. Conclusions: TLD, OSL dosimeters, and EBT films are suitable for pulsed beams with a very high pulse dose rate like laser accelerated particle beams.

  2. SU-D-213-07: Initial Characterization of a Gel Patch Dosimeter for in Vivo Dosimetry

    SciTech Connect

    Matrosic, C; Culberson, W; Rosen, B; Madsen, E; Frank, G; Bednarz, B

    2015-06-15

    Purpose: In vivo dosimetry, despite being the most direct method for monitoring the dose delivered during radiation therapy and being recommended by several national and international organizations (AAPM, ICRU, NACP), is underutilized in the clinic due to issues associated with dose sensitivity, feasibility, and cost. Given the increasing complexity of radiation therapy modern treatments, there is a compelling need for a robust, affordable in vivo dosimetry option. In this work we present the initial characterization of a novel gel patch in vivo dosimeter. Methods: DEFGEL (6%T) was used to make 1-cm thick small cylindrical patch dosimeters. The optical density of each dosimeter was read before and after irradiation by an in-house laser densitometer. The dosimeters were irradiated using a Varian Clinac EX linac. Three separate batches of gel patches were used to create dose response curves and evaluate repeatability. The development time of the dosimeter was also evaluated. Results: The dose response of the dosimeter was found to be linear from a range of approximately 1-Gy to 20-Gy, which is a larger window of linearity compared to other in vivo dosimeters. At doses below 1-Gy, the cumulative uncertainties were on the order of the measured data. When compared, the three batches demonstrated repeatability from 1-Gy to approximately 13-Gy, with some variation at higher doses. For doses of >8-Gy, the dosimeter reached full optical density after 4-hours, whereas low doses developed within an hour. Conclusion: Initial results indicate that the gel patch dosimeter is a reliable and simple way to measure a large range of doses, including high doses such as those delivered during hypofractionated treatments (e.g. SBRT or MR-guided radiotherapy). The simple fabrication method for the dosimeter and the use of a laser densitometer would allow for the dosimeter to used and read in-house, cheaply and easily.

  3. A search for novel thermoluminescent radiation dosimeter media.

    PubMed

    Al-Hinai, Khalid H; Benkara Mohd, Nadjima; Rozullyah Zulkepely, Nurul; Md Nor, Roslan; Mohd Amin, Yusoff; Bradley, D A

    2013-12-01

    We describe two example pilot efforts to help define new thermoluminescent dosimeter media. The first concerns ZnS:Mn nanophosphors, prepared by chemical precipitation using zinc and sodium sulfate, doped with manganese sulfate at concentrations varying from 1 to 3mol. The second concerns chemical vapor deposited diamond, produced as a thin film or as amorphous carbon on a single-crystal silicon substrate, each deposited under the same conditions, use being made of the hot filament-chemical vapor deposition (HFCVD) technique. The gas concentrations used were 1% CH4 in 99% H2 and 25% CH4 in 75% H2. Characterization of formations used FESEM, XRD and EDX. The nanophosphors consisted of particles of sizes in the range 85-150nm, the thermoluminescence (TL)-based radiation detection medium giving rise to a single peaked glow curve of maximum yield at a temperature of 250°C at a heating rate of 5°C/s. The TL response increased linearly with radiation dose, ZnS doped to 2mol of Mn being found the most sensitive. Regarding chemical vapor deposited (CVD) carbon, inappreciable TL was found for the resultant ball-like amorphous carbon films, graphite, and the silicon substrate, whereas CVD diamond films showed a promising degree of linearity with dose. For both the ZnS and diamond samples, TL signal fading was appreciable, being some 40% per day for ZnS and>50% per day for CVD films even under storage in the dark at room temperature, making it apparent that there is need to adjust parameters such as the size of nanoparticles. © 2013 Elsevier Ltd. All rights reserved.

  4. 128 slice computed tomography dose profile measurement using thermoluminescent dosimeter

    NASA Astrophysics Data System (ADS)

    Salehhon, N.; Hashim, S.; Karim, M. K. A.; Ang, W. C.; Musa, Y.; Bahruddin, N. A.

    2017-05-01

    The increasing use of computed tomography (CT) in clinical practice marks the needs to understand the dose descriptor and dose profile. The purposes of the current study were to determine the CT dose index free-in-air (CTDIair) in 128 slice CT scanner and to evaluate the single scan dose profile (SSDP). Thermoluminescent dosimeters (TLD-100) were used to measure the dose profile of the scanner. There were three sets of CT protocols where the tube potential (kV) setting was manipulated for each protocol while the rest of parameters were kept constant. These protocols were based from routine CT abdominal examinations for male adult abdomen. It was found that the increase of kV settings made the values of CTDIair increased as well. When the kV setting was changed from 80 kV to 120 kV and from 120 kV to 140 kV, the CTDIair values were increased as much as 147.9% and 53.9% respectively. The highest kV setting (140 kV) led to the highest CTDIair value (13.585 mGy). The p-value of less than 0.05 indicated that the results were statistically different. The SSDP showed that when the kV settings were varied, the peak sharpness and height of Gaussian function profiles were affected. The full width at half maximum (FWHM) of dose profiles for all protocols were coincided with the nominal beam width set for the measurements. The findings of the study revealed much information on the characterization and performance of 128 slice CT scanner.

  5. Radio-physical properties of micelle leucodye 3D integrating gel dosimeters

    NASA Astrophysics Data System (ADS)

    Vandecasteele, J.; Ghysel, S.; Baete, S. H.; De Deene, Y.

    2011-02-01

    Recently, novel radiochromic leucodye micelle hydrogel dosimeters were introduced in the literature. In these studies, gel measured electron depth dose profiles were compared with ion chamber depth dose data, from which it was concluded that leucocrystal violet-type dosimeters were independent of dose rate. Similar conclusions were drawn for leucomalachite green-type dosimeters, only after pre-irradiating the samples to a homogeneous radiation dose. However, in our extensive study of the radio-physical properties of leucocrystal violet- and leucomalachite green-type dosimeters, a significant dose rate dependence was found. For a dose rate variation between 50 and 400 cGy\\,min^{-1}, a maximum difference of 75% was found in optical dose sensitivity for the leucomalachite green-type dosimeter. Furthermore, the measured optical dose sensitivity of the leucomalachite green-type dosimeter was four times lower than the value previously reported in the literature. For the leucocrystal violet-type dosimeter, a maximum difference in optical dose sensitivity of 55% was found between 50 and 400 cGy\\,min^{-1}. A modified composition of the leucomalachite green-type dosimeter is proposed. This dosimeter is composed of gelatin, sodium dodecyl sulfate, chloroform, trichloroacetic acid and leucomalachite green. The optical dose sensitivity amounted to 4.375 \\times 10^{-5} \\,cm^{-1}\\; cGy^{-1} (dose rate 400 cGy\\,min^{-1}). No energy dependence for photon energies between 6 and 18 MV was found. No temperature dependence during readout was found notwithstanding a temperature dependence during irradiation of 1.90 cGy °C-1 increase on a total dose of 100 cGy. The novel gel dosimeter formulation exhibits an improved spatial stability (2.45 \\times 10^{-7} \\,cm^{2}\\; s^{-1} (= 0.088 mm^2 \\; h^{-1})) and good water/soft tissue equivalence. Nevertheless, the novel formulation was also found to have a significant, albeit reduced, dose rate dependence, as a maximum difference of 33

  6. The study of N-isopropylacrylamide gel dosimeter doped iodinated contrast agents

    NASA Astrophysics Data System (ADS)

    Chang, Y. J.; Hsieh, L. L.; Liu, M. H.; Liu, J. S.; Hsieh, B. T.

    2013-06-01

    Low toxicity of N-isopropylacrylamide (NIPAM) dosimeter was doped with clinical iodinated contrast medium agents(Iobitridol (Xenetix® 350) and organically bound iodine (Conray® 60) as radiation sensitizers; The suitable gel dosimeter preparation formula in this research was 5 w/w% gelatin, 5 w/w% N-isopropylacrylamide, 3 w/w% N,N-methylene-bis-acrylamide, and 5 mM Tetrakis phosphonium chloride. The spiral CT was irradiator, and 120 kVp was the operating tube voltage. The maximum radiation dose was 0.6 Gy, and optical CT was the gel measurement device used. The results showed SERs with the addition of radiosensitizers were 10.70 (Xenetix® 350) and 9.67 (Conray® 60), respectively. Thus, the polymerized gel dosimeter could be used in the efficacy evaluation of low-energy and low-radiation dose.

  7. Dose integration and dose rate characteristics of a NiPAM polymer gel MRI dosimeter system

    NASA Astrophysics Data System (ADS)

    Waldenberg, C.; Karlsson Hauer, A.; Gustafsson, C.; Ceberg, S.

    2017-05-01

    The normoxic polymer gel dosimeter based on N-isopropyl acrylamide (NiPAM) is a promising full 3D-dosimeter with high spatial resolution and near tissue equivalency. NiPAM gel samples were irradiated to different doses using a linear accelerator. The absorbed dose was evaluated using MRI and statistical significance of the analysed data was calculated. The analysis was carried out using an in-house developed software. It was found that the gel dosimeter responded linearly to the absorbed dose. The gel exhibited a dose rate dependence, as well as a dependence on the sequential beam irradiation scheme. A higher dose rate, as well as a higher dose per sequential beam, resulted in a lower dose response.

  8. Optical properties of a long dynamic range chemical UV dosimeter based on solvent cast polyvinyl chloride (PVC).

    PubMed

    Amar, Abdurazaq; Parisi, Alfio V

    2013-11-05

    The dosimetric properties of the recently introduced UV dosimeter based on 16 μm PVC film have been fully characterised. Drying the thin film in air at 50 °C for at least 28 days was found to be necessary to minimise the temperature effects on the dosimeter response. This research has found that the dosimeter response, previously reported to be mainly to UVB, has no significant dependence on either exposure temperature or dose rate. The dosimeter has negligible dark reaction and responds to the UV radiation with high reproducibility. The dosimeter angular response was found to have a similar pattern as the cosine function but deviates considerably at angles larger than 70°. Dose response curves exhibit monotonically increasing shape and the dosimeter can measure more than 900 SED. This is about 3 weeks of continuous exposure during summer at subtropical sites. Exposures measured by the PVC dosimeter for some anatomical sites exposed to solar radiation for twelve consecutive days were comparable with those concurrently measured by a series of PPO dosimeters and were in line with earlier results reported in similar studies.

  9. Method for correcting for isotope burn-in effects in fission neutron dosimeters

    DOEpatents

    Gold, Raymond; McElroy, William N.

    1988-01-01

    A method is described for correcting for effect of isotope burn-in in fission neutron dosimeters. Two quantities are measured in order to quantify the "burn-in" contribution, namely P.sub.Z',A', the amount of (Z', A') isotope that is burned-in, and F.sub.Z', A', the fissions per unit volume produced in the (Z', A') isotope. To measure P.sub.Z', A', two solid state track recorder fission deposits are prepared from the very same material that comprises the fission neutron dosimeter, and the mass and mass density are measured. One of these deposits is exposed along with the fission neutron dosimeter, whereas the second deposit is subsequently used for observation of background. P.sub.Z', A' is then determined by conducting a second irradiation, wherein both the irradiated and unirradiated fission deposits are used in solid state track recorder dosimeters for observation of the absolute number of fissions per unit volume. The difference between the latter determines P.sub.Z', A' since the thermal neutron cross section is known. F.sub.Z', A' is obtained by using a fission neutron dosimeter for this specific isotope, which is exposed along with the original threshold fission neutron dosimeter to experience the same neutron flux-time history at the same location. In order to determine the fissions per unit volume produced in the isotope (Z', A') as it ingrows during the irradiation, B.sub.Z', A', from these observations, the neutron field must generally be either time independent or a separable function of time t and neutron energy E.

  10. SU-E-T-274: Does Atmospheric Oxygen Affect the PRESAGE Dosimeter?

    SciTech Connect

    Alqathami, M; Ibbott, G; Blencowe, A

    2015-06-15

    Purpose: To experimentally determine the influence of atmospheric oxygen on the efficiency of the PRESAGE dosimeter and its reporting system. Methods: Batches of the reporting system – a mixture of chloroform and leuchomalachite green dye – and PRESAGE were prepared in aerobic and anaerobic conditions. For anaerobic batches, samples were deoxygenated by bubbling nitrogen through the dosimeter precursors or reporting system for 10 min. The dosimeters and reporting systems were prepared in spectrophotometric cuvettes and glass vials, respectively, and were irradiated with 6 MV photons to various radiation doses using a clinical linear accelerator. Changes in optical density of the dosimeters and reporting system before and after irradiation were measured using a spectrophotometer. In addition, the concentrations of dissolved oxygen were measured using a dissolved oxygen meter. Results: The experiments revealed that oxygen has little influence on the characteristics of PRESAGE, with the radical initiator oxidizing the leucomalachite green even in the presence of oxygen. However, deoxygenation of the reporting system leads to an increase in sensitivity to radiation dose by ∼ 30% when compared to the non-deoxygenated system. A slight improvement in sensitivity (∼ 5%) was also achieved by deoxygenating the PRESAGE precursor prior to casting. Measurement of the dissolved oxygen revealed low levels (0.4 ppm) in the polyurethane precursor used to fabricate the dosimeters, as compared to water (8.6 ppm). In addition, deoxygenation had no effect on the retention of the post-response absorption value of the PRESAGE dosimeter. Conclusion: The results suggest that the presence of oxygen does not inhibit the radiochromic properties of the PRESAGE system. In addition, there were no observed changes in the dose linearity, absorption spectrum and post-response photofading characteristics of the PRESAGE under the conditions investigated.

  11. SU-D-213-06: Dosimetry of Modulated Electron Radiation Therapy Using Fricke Gel Dosimeter

    SciTech Connect

    Gawad, M Abdel; Elgohary, M; Hassaan, M; Emam, M; Desouky, O; Eldib, A; Ma, C

    2015-06-15

    Purpose: Modulated electron radiation therapy (MERT) has been proposed as an effective modality for treatment of superficial targets. MERT utilizes multiple beams of different energies which are intensity modulated to deliver optimized dose distribution. Energy independent dosimeters are thus needed for quantitative evaluations of MERT dose distributions and measurements of absolute doses delivered to patients. Thus in the current work we study the feasibility of Fricke gel dosimeters in MERT dosimetry. Methods: Batches of radiation sensitive Fricke gel is fabricated and poured into polymethyl methacrylate cuvettes. The samples were irradiated in solid water phantom and a thick layer of bolus was used as a buildup. A spectrophotometer system was used for measuring the color changes (the absorbance) before and after irradiation and then we calculate net absorbance. We constructed calibration curves to relate the measured absorbance in terms of absorbed dose for all available electron energies. Dosimetric measurements were performed for mixed electron beam delivery and we also performed measurement for segmented field delivery with the dosimeter placed at the junction of two adjacent electron beams of different energies. Dose measured by our gel dosimetry is compared to that calculation from our precise treatment planning system. We also initiated a Monte Carlo study to evaluate the water equivalence of our dosimeters. MCBEAM and MCSIM codes were used for treatment head simulation and phantom dose calculation. PDDs and profiles were calculated for electron beams incident on a phantom designed with 1cm slab of Fricke gel. Results: The calibration curves showed no observed energy dependence with all studied electron beam energies. Good agreement was obtained between dose calculated and that obtained by gel dosimetry. Monte Carlo results illustrated the tissue equivalency of our Gel dosimeters. Conclusion: Fricke Gel dosimeters represent a good option for the dosimetric

  12. SU-E-T-643: Pure Alanine Dosimeter for Verification Dosimetry in IMRT

    SciTech Connect

    Al-Karmi, Anan M.; Zraiqat, Fadi

    2015-06-15

    Purpose: The objective of this study was evaluation of accuracy of pure alanine dosimeters measuring intensity-modulated radiation therapy (IMRT) dose distributions in a thorax phantom. Methods: Alanine dosimeters were prepared in the form of 110 mg pure L-α-alanine powder filled into clear tissue-equivalent polymethylmethacrylate (PMMA) plastic tubes with the dimensions 25 mm length, 3 mm inner diameter, and 1 mm wall thickness. A dose-response calibration curve was established for the alanine by placing the dosimeters at 1.5 cm depth in a 30×30×30 cm{sup 3} solid water phantom and then irradiating on a linac with 6 MV photon beam at 10×10 cm{sup 2} field size to doses ranging from 1 to 5 Gy. Electron paramagnetic resonance (EPR) spectroscopy was used to determine the absorbed dose in alanine. An IMRT treatment plan was designed for a commercial heterogeneous CIRS thorax phantom and the dose values were calculated at three different points located in tissue, lung, and bone equivalent materials. A set of dose measurements was carried out to compare measured and calculated dose values by placing the alanine dosimeters at those selected locations inside the thorax phantom and delivering the IMRT to the phantom. Results: The alanine dose measurements and the IMRT plan dose calculations were found to be in agreement within ±2%. Specifically, the deviations were −0.5%, 1.3%, and −1.7% for tissue, lung, and bone; respectively. The slightly large deviations observed for lung and bone may be attributed to tissue inhomogeneity, steep dose gradients in these regions, and uncontrollable changes in spectrometer conditions. Conclusion: The results described herein confirmed that pure alanine dosimeter was suitable for in-phantom dosimetry of IMRT beams because of its high sensitivity and acceptable accuracy. This makes the dosimeter a promising option for quality control of the therapeutic beams, complementing the commonly used ionization chambers, TLDs, and films.

  13. The energy dependence of lithium formate and alanine EPR dosimeters for medium energy x rays

    SciTech Connect

    Waldeland, Einar; Hole, Eli Olaug; Sagstuen, Einar; Malinen, Eirik

    2010-07-15

    Purpose: To perform a systematic investigation of the energy dependence of alanine and lilthium formate EPR dosimeters for medium energy x rays. Methods: Lithium formate and alanine EPR dosimeters were exposed to eight different x-ray beam qualities, with nominal potentials ranging from 50 to 200 kV. Following ionometry based on standards of absorbed dose to water, the dosimeters were given two different doses of approximately 3 and 6 Gy for each radiation quality, with three dosimeters for each dose. A reference series was also irradiated to three different dose levels at a {sup 60}Co unit. The dose to water energy response, that is, the dosimeter reading per absorbed dose to water relative to that for {sup 60}Co {gamma}-rays, was estimated for each beam quality. In addition, the energy response was calculated by Monte Carlo simulations and compared to the experimental energy response. Results: The experimental energy response estimates ranged from 0.89 to 0.94 and from 0.68 to 0.90 for lithium formate and alanine, respectively. The uncertainties in the experimental energy response estimates were typically 3%. The relative effectiveness, that is, the ratio of the experimental energy response to that following Monte Carlo simulations was, on average, 0.96 and 0.94 for lithium formate and alanine, respectively. Conclusions: This work shows that lithium formate dosimeters are less dependent on x-ray energy than alanine. Furthermore, as the relative effectiveness for both lithium formate and alanine were systematically less than unity, the yield of radiation-induced radicals is decreased following x-irradiation compared to irradiation with {sup 60}Co {gamma}-rays.

  14. Study of the absorption spectra of Fricke Xylenol Orange gel dosimeters

    SciTech Connect

    Gambarini, Grazia; Artuso, Emanuele; Liosi, Giulia Maria; Giacobbo, Francesca; Mariani, Mari; Brambilla, Luigi; Castiglioni, Chiara; Carrara, Mauro; Pignoli, Emanuele

    2015-07-01

    A systematic study of the absorption spectra of Fricke Xylenol Orange gel dosimeters has been performed, in the wavelength range from 300 nm to 700 nm. The spectrum of Xylenol Orange (without ferrous sulphate solution) has been achieved, in order to subtract its contribution from the absorption spectra of the irradiated Fricke Xylenol Orange gel dosimeters. The absorbance due to ferric ions chelated by Xylenol Orange has been studied for various irradiation doses. Two absorbance peaks are visible, mainly at low doses: the first peak increases with the dose more slowly than the second one. This effect can explain the apparent threshold dose that was frequently evidenced. (authors)

  15. Novel Multicompartment 3-Dimensional Radiochromic Radiation Dosimeters for Nanoparticle-Enhanced Radiation Therapy Dosimetry

    SciTech Connect

    Alqathami, Mamdooh; Blencowe, Anton; Yeo, Un Jin; Doran, Simon J.; Qiao, Greg; Geso, Moshi

    2012-11-15

    Purpose: Gold nanoparticles (AuNps), because of their high atomic number (Z), have been demonstrated to absorb low-energy X-rays preferentially, compared with tissue, and may be used to achieve localized radiation dose enhancement in tumors. The purpose of this study is to introduce the first example of a novel multicompartment radiochromic radiation dosimeter and to demonstrate its applicability for 3-dimensional (3D) dosimetry of nanoparticle-enhanced radiation therapy. Methods and Materials: A novel multicompartment phantom radiochromic dosimeter was developed. It was designed and formulated to mimic a tumor loaded with AuNps (50 nm in diameter) at a concentration of 0.5 mM, surrounded by normal tissues. The novel dosimeter is referred to as the Sensitivity Modulated Advanced Radiation Therapy (SMART) dosimeter. The dosimeters were irradiated with 100-kV and 6-MV X-ray energies. Dose enhancement produced from the interaction of X-rays with AuNps was calculated using spectrophotometric and cone-beam optical computed tomography scanning by quantitatively comparing the change in optical density and 3D datasets of the dosimetric measurements between the tissue-equivalent (TE) and TE/AuNps compartments. The interbatch and intrabatch variability and the postresponse stability of the dosimeters with AuNps were also assessed. Results: Radiation dose enhancement factors of 1.77 and 1.11 were obtained using 100-kV and 6-MV X-ray energies, respectively. The results of this study are in good agreement with previous observations; however, for the first time we provide direct experimental confirmation and 3D visualization of the radiosensitization effect of AuNps. The dosimeters with AuNps showed small (<3.5%) interbatch variability and negligible (<0.5%) intrabatch variability. Conclusions: The SMART dosimeter yields experimental insights concerning the spatial distributions and elevated dose in nanoparticle-enhanced radiation therapy, which cannot be performed using any of

  16. A Bremsstrahlung Spectrometer using k-edge and Differential Filters with Image plate dosimeters

    SciTech Connect

    Chen, C; Mackinnon, A; Beg, F; Chen, H; Key, M; King, J A; Link, A; MacPhee, A; Patel, P; Porkolab, M; Stephens, R; VanWoerkom, L; Akli, K; Freeman, R

    2008-05-02

    A Bremsstrahlung spectrometer using k-edge and differential filtering has been used with Image Plate dosimeters to measure the x-ray fluence from short-pulse laser/target interactions. An electron spectrometer in front of the Bremsstrahlung spectrometer deflects electrons from the x-ray line of sight and simultaneously measures the electron spectrum. The response functions were modeled with the Monte Carlo code Integrated Tiger Series 3.0 and the dosimeters calibrated with radioactive sources. Electron distributions with slope temperatures in the MeV range are inferred from the Bremsstrahlung spectra.

  17. A Bremsstrahlung spectrometer using k-edge and differential filters with image plate dosimeters

    SciTech Connect

    Chen, C. D.; Porkolab, M.; King, J. A.; Beg, F. N.; Key, M. H.; Chen, H.; Mackinnon, A. J.; MacPhee, A. G.; Patel, P. K.; Akli, K. U.; Stephens, R. B.; Freeman, R. R.; Link, A.; Van Woerkom, L. D.

    2008-10-15

    A Bremsstrahlung spectrometer using k-edge and differential filtering has been used with image plate dosimeters to measure the x-ray fluence from short-pulse laser/target interactions. An electron spectrometer in front of the Bremsstrahlung spectrometer deflects electrons from the x-ray line of sight and simultaneously measures the electron spectrum. The response functions were modeled with the Monte Carlo code INTEGRATED TIGER SERIES 3.0 and the dosimeters calibrated with radioactive sources. An electron distribution with a slope temperature of 1.3 MeV is inferred from the Bremsstrahlung spectra.

  18. Experimental determination of the influence of oxygen on the PRESAGE® dosimeter.

    PubMed

    Alqathami, Mamdooh; Blencowe, Anton; Ibbott, Geoffrey

    2016-01-21

    It is generally accepted that the PRESAGE(®) radiochromic dosimeter is not sensitive to oxygen, however, this claim has not been supported or verified experimentally. Therefore, the aim of this study was to experimentally determine the potential influence of oxygen on dose sensitivity of the PRESAGE(®) dosimeter and its reporting system. Batches of PRESAGE(®) and its radical initiator-leuco dye reporting system were prepared in aerobic and anaerobic conditions. The anaerobic batches were deoxygenated by bubbling nitrogen through the dosimeter precursors or reporting system for 10 min. The dosimeters and reporting systems were prepared in spectrophotometric cuvettes and glass vials, respectively, and were irradiated with 6 MV photons to various radiation doses. Changes in optical density of the dosimeters and reporting system before and after irradiation were measured using a spectrophotometer. The overall results show that oxygen has some influence on the dosimetric characteristics of PRESAGE(®), although the radical initiator does appear to oxidize the leucomalachite green even in the presence of oxygen. Deoxygenation of the reporting system leads to an increase in sensitivity to radiation dose by ~30% when compared to the non-deoxygenated system. A minor increase in sensitivity (~5%) was also achieved by deoxygenating the PRESAGE(®) precursor prior to casting. In addition, dissolved oxygen measurements revealed low levels of dissolved oxygen (0.40 ± 0.04 mg l(-1)) in the polyurethane precursor used to fabricate the PRESAGE(®) dosimeters, as compared to water (8.60 ± 0.03 mg l(-1)) and the reporting system alone (1.30 ± 0.10 mg l(-1)). The results suggest that the presence of oxygen does not inhibit the radiochromic properties of the PRESAGE(®) system. However, deoxygenation of the dosimeter precursors prior to casting improves the dosimeters dose sensitivity by ~5%, which might be particularly useful for measuring low radiation doses. Nevertheless, we

  19. Neutron dosimetry at commercial nuclear plants. Final report of Subtask B: dosimeter response

    SciTech Connect

    Cummings, F.M.; Endres, G.W.R.; Brackenbush, L.W.

    1983-03-01

    As part of a larger program to evaluate personnel neutron dosimetry at commercial nuclear power plants, this study was designed to characterize neutron dosimeter responses inside the containment structure of commercial nuclear plants. In order to characterize those responses, dosimeters were irradiated inside containment at 2 pressurized water reactors and at pipe penetrations outside the biological shield at two boiling water reactors. The reactors were operating at full power during the irradiations. Measurements were also performed with electronic instruments, the tissue equivalent proportional counter (TEPC), and portable remmeters, SNOOPY, RASCAL and PNR-4.

  20. Initial characterization of a gel patch dosimeter for in vivo dosimetry.

    PubMed

    Matrosic, C; Culberson, W; Rosen, B; Madsen, E; Frank, G; Bednarz, B

    2016-05-21

    In vivo dosimetry is a greatly underutilized tool for patient safety in clinical external beam radiotherapy treatments, despite being recommended by several national and international organizations (AAPM, ICRU, IAEA, NACP). The reasons for this underutilization mostly relate to the feasibility and cost of in vivo dosimetry methods. Due to the increase in the number of beam angles and dose per fraction in modern treatments, there is a compelling need for a novel dosimeter that is robust and affordable while able to operate properly in these complex conditions. This work presents a gel patch dosimeter as a novel method of in vivo dosimetry. DEFGEL, a 6% T normoxic polyacrylamide gel, was injected into 1 cm thick acrylic molds to create 1 cm thick small cylindrical patch dosimeters. To evaluate the change in optical density due to radiation induced polymerization, dosimeters were scanned before and after irradiation using an in-house developed laser densitometer. The dose-responses of three separate batches of gel were evaluated and compared to check for linearity and repeatability. The response development time was evaluated to ensure that the patch dosimeter could be high throughput. Additionally, the potential of this system to be used as an in vivo dosimeter was tested with a clinically relevant end-to-end in vivo phantom test. All irradiations were performed with a Varian Clinac 21EX at the University of Wisconsin Medical Radiation Research Center (UWMRRC). The dose-response of all three batches of gel was found to be linear within the range of 2-20 Gy. At doses below 0.5 Gy the statistical uncertainties were prohibitively large to make quantitative assessments of the results. The three batches demonstrated good repeatability in the range of 2 Gy to up to 10 Gy, with only slight variations in response at higher doses. For low doses the dosimeter fully developed within an hour while at higher doses they fully developed within four hours. During the in vivo

  1. Experimental determination of the influence of oxygen on the PRESAGE® dosimeter

    NASA Astrophysics Data System (ADS)

    Alqathami, Mamdooh; Blencowe, Anton; Ibbott, Geoffrey

    2016-01-01

    It is generally accepted that the PRESAGE® radiochromic dosimeter is not sensitive to oxygen, however, this claim has not been supported or verified experimentally. Therefore, the aim of this study was to experimentally determine the potential influence of oxygen on dose sensitivity of the PRESAGE® dosimeter and its reporting system. Batches of PRESAGE® and its radical initiator-leuco dye reporting system were prepared in aerobic and anaerobic conditions. The anaerobic batches were deoxygenated by bubbling nitrogen through the dosimeter precursors or reporting system for 10 min. The dosimeters and reporting systems were prepared in spectrophotometric cuvettes and glass vials, respectively, and were irradiated with 6 MV photons to various radiation doses. Changes in optical density of the dosimeters and reporting system before and after irradiation were measured using a spectrophotometer. The overall results show that oxygen has some influence on the dosimetric characteristics of PRESAGE®, although the radical initiator does appear to oxidize the leucomalachite green even in the presence of oxygen. Deoxygenation of the reporting system leads to an increase in sensitivity to radiation dose by ~30% when compared to the non-deoxygenated system. A minor increase in sensitivity (~5%) was also achieved by deoxygenating the PRESAGE® precursor prior to casting. In addition, dissolved oxygen measurements revealed low levels of dissolved oxygen (0.40  ±  0.04 mg l-1) in the polyurethane precursor used to fabricate the PRESAGE® dosimeters, as compared to water (8.60  ±  0.03 mg l-1) and the reporting system alone (1.30  ±  0.10 mg l-1). The results suggest that the presence of oxygen does not inhibit the radiochromic properties of the PRESAGE® system. However, deoxygenation of the dosimeter precursors prior to casting improves the dosimeters dose sensitivity by ~5%, which might be particularly useful for measuring low radiation doses

  2. Initial characterization of a gel patch dosimeter for in vivo dosimetry

    NASA Astrophysics Data System (ADS)

    Matrosic, C.; Culberson, W.; Rosen, B.; Madsen, E.; Frank, G.; Bednarz, B.

    2016-05-01

    In vivo dosimetry is a greatly underutilized tool for patient safety in clinical external beam radiotherapy treatments, despite being recommended by several national and international organizations (AAPM, ICRU, IAEA, NACP). The reasons for this underutilization mostly relate to the feasibility and cost of in vivo dosimetry methods. Due to the increase in the number of beam angles and dose per fraction in modern treatments, there is a compelling need for a novel dosimeter that is robust and affordable while able to operate properly in these complex conditions. This work presents a gel patch dosimeter as a novel method of in vivo dosimetry. DEFGEL, a 6% T normoxic polyacrylamide gel, was injected into 1 cm thick acrylic molds to create 1 cm thick small cylindrical patch dosimeters. To evaluate the change in optical density due to radiation induced polymerization, dosimeters were scanned before and after irradiation using an in-house developed laser densitometer. The dose-responses of three separate batches of gel were evaluated and compared to check for linearity and repeatability. The response development time was evaluated to ensure that the patch dosimeter could be high throughput. Additionally, the potential of this system to be used as an in vivo dosimeter was tested with a clinically relevant end-to-end in vivo phantom test. All irradiations were performed with a Varian Clinac 21EX at the University of Wisconsin Medical Radiation Research Center (UWMRRC). The dose-response of all three batches of gel was found to be linear within the range of 2-20 Gy. At doses below 0.5 Gy the statistical uncertainties were prohibitively large to make quantitative assessments of the results. The three batches demonstrated good repeatability in the range of 2 Gy to up to 10 Gy, with only slight variations in response at higher doses. For low doses the dosimeter fully developed within an hour while at higher doses they fully developed within four hours. During the in vivo

  3. A gelatin-free model system for the study of the basic radiation-induced polymerization in PAG dosimeters

    NASA Astrophysics Data System (ADS)

    Babic, S.; Park, Y. S.; Schreiner, L. J.

    2004-01-01

    In this presentation we show results of investigations on gelatin-free dosimeters containing equal amounts of acrylamide and N,N'-methylene-bisacrylamide (named Aqueous Polyacrylamide, APA, dosimeters). The dosimeters were prepared with three different total monomer concentrations (2, 6, and 8% by weight). Nuclear magnetic resonance (NMR) spin-spin and spin-lattice proton relaxation measurements at 20 MHz, and gravimetric analyses performed on all three dosimeters, show a continuous degree of polymerization over the range of dose 0.5 - 25 Gy. The developed NMR model explains the relationship observed between the relaxation data and the amount of cross-linked polymer formed at each dose. This model may be extended with gelatin relaxation data to provide a fundamental understanding of radiation-induced polymerization in the conventional PAG dosimeters.

  4. Enhancement in dose sensitivity of polymer gel dosimeters composed of radiation-crosslinked gel matrix and less toxic monomers

    NASA Astrophysics Data System (ADS)

    Hiroki, A.; Yamashita, S.; Taguchi, M.

    2015-01-01

    Polymer gel dosimeters based on radiation-crosslinked hydroxypropyl cellulose gel were prepared, which comprised 2-hydroxyethyl methacrylate (HEMA) and polyethylene glycol #400 dimethacrylate (9G) as less toxic monomers and tetrakis (hydroxymethyl) phosphonium chloride (THPC) as an antioxidant. The dosimeters exposed to 60Co γ-rays became cloudy at only 1 Gy. The irradiated dosimeters were optically analyzed by using a UV- vis spectrophotometer to evaluate dose response. Absorbance of the dosimeters linearly increased in the dose range from 0 to 10 Gy, in which dose sensitivity increased with increasing 9G concentration. The dose sensitivity of the dosimeters with 2 wt% HEMA and 3 wt% 9G was also enhanced by increment in THPC.

  5. Optical CT and MR imaging of radiation dose distributions using the FBX-gel dosimeter

    NASA Astrophysics Data System (ADS)

    Kelly, Robin G.

    In recent years, magnetic resonance imaging of gelatin doped with the Fricke solution has been applied to the direct measurement of three-dimensional (3D) dose distributions. However, the 3D-dose distribution can also be imaged more economically and efficiently using the method of optical absorption computed tomography. This is accomplished by first preparing a gelatin matrix containing a radiochromic dye and mapping the radiation-induced local change in the optical absorption coefficient. Ferrous Sulphate-Benzoic Acid-Xylenol Orange (FBX) was the dye of choice for this investigation. The complex formed by Fe 3+ and xylenol orange exhibits a linear change in optical attenuation (cm-1) with radiation dose in the range between 0 and 1000 cGy, and the local concentration of this complex can be probed using a green laser light (lambda = 543.5 nm). An optical computed tomography (CT) scanner was constructed analogous to a first-generation x-ray CT scanner, using a He-Ne laser, photodiodes, and rotation-translation stages controlled by a personal computer. The optical CT scanner itself can reconstruct attenuation coefficients to a baseline accuracy of <2% while yielding dose images accurate to within 5% when other uncertainties are taken into account. The radiation-induced conversion of ferrous ion (Fe2+) to ferric ion (Fe3+) in the FBX Gelatin dosimeter can also be measured using magnetic resonance imaging, similar to the standard Fricke-gelatin system. The oxidation process causes a shortening of the spin-spin (T 2), and spin-lattice (T1) relaxation times, each of which can be measured, with varying accuracy and precision, using different MR pulse sequences. In this investigation, the spin-lattice relaxation times of FBX gelatin were determined using both a fast inversion recovery pulse-sequence, and a three-dimensional Look-Locker (3D-LL) pulse-sequence. The inverse spin-lattice relaxation time (R1 = 1/T1) is shown to vary linearly with absorbed dose in the range 500

  6. An in-house developed resettable MOSFET dosimeter for radiotherapy.

    PubMed

    Verellen, Dirk; Van Vaerenbergh, Sven; Tournel, Koen; Heuninckx, Karina; Joris, Laurent; Duchateau, Michael; Linthout, Nadine; Gevaert, Thierry; Reynders, Truus; Van de Vondel, Iwein; Coppens, Luc; Depuydt, Tom; De Ridder, Mark; Storme, Guy

    2010-02-21

    The purpose of this note is to report the feasibility and clinical validation of an in-house developed MOSFET dosimetry system and describe an integrated non-destructive reset procedure. Off-the-shelf MOSFETs are connected to a common PC using an 18 bit/analogue-input and 16 bit/output data acquisition card. A reading algorithm was developed defining the zero-temperature-coefficient point (ZTC) to determine the threshold voltage. A wireless interface was established for ease of use. The reset procedure consists of an internal circuit generating a local heating induced by an electrical current. Sensitivity has been investigated as a function of bias voltage (0-9 V) to the gate. Dosimetric properties have been evaluated for 6 MV and 15 MV clinical photon beams and in vivo benchmarking was performed against thermoluminescence dosimeters (TLD) for conventional treatments (two groups of ten patients for each energy) and total body irradiation (TBI). MOSFETS were pre-irradiated with 20 Gy. Sensitivity of 0.08 mV cGy(-1) can be obtained for 200 cGy irradiations at 5 V bias voltage. Ten consecutive measurements at 200 cGy yield a SD of 2.08 cGy (1.05%). Increasing the dose in steps from 5 cGy to 1000 cGy yields a 1.00 Pearson correlation coefficient and agreement within 2.0%. Dose rate dependence (160-800 cGy min(-1)) was within 2.5%, temperature dependence within 2.0% (25-37 degrees C). A strong angular dependence has been observed for gantry incidences exceeding +/-30 degrees C. Dose response is stable up to 50 Gy (saturation occurs at approximately 90 Gy), which is used as threshold dose before resetting the MOSFET. An average measured-over-calculated dose ratio within 1.05 (SD: 0.04) has been obtained in vivo. TBI midplane-dose assessed by entrance and exit dose measurements agreed within 1.9% with ionization chamber in phantom, and within 1.0% with TLD in vivo. An in-house developed resettable MOSFET-based dosimetry system is proposed. The system has been validated

  7. Verification of 3D Dose Distributions of a Beta-Emitting Radionuclide Using PRESAGE^ Dosimeters

    NASA Astrophysics Data System (ADS)

    Crowder, Mandi; Grant, Ryan; Ibbott, Geoff; Wendt, Richard

    2010-11-01

    Liquid Brachytherapy involves the direct administration of a beta-emitting radioactive solution into the selected tissue. The solution does not migrate from the injection point and uses the limited range of beta particles to produce a three-dimensional dose distribution. We simulated distributions by beta-dose kernels and validated those estimates by irradiating PRESAGE^ polyurethane dosimeters that measure the three-dimensional dose distributions by a change in optical density that is proportional to dose. The dosimeters were injected with internal beta-emitting radionuclide yttrium-90, exposed for 5.75 days, imaged with optical tomography, and analyzed with radiotherapy software. Dosimeters irradiated with an electron beam to 2 or 3 Gy were used for calibration. The shapes and dose distributions in the PRESAGE^ dosimeters were consistent with the predicted dose kernels. Our experiments have laid the groundwork for future application to individualized patient therapy by ultimately designing a treatment plan that conforms to the shape of any appropriate tumor.

  8. Method and apparatus for passive optical dosimeter comprising caged dye molecules

    DOEpatents

    Sandison, David R.

    2001-07-03

    A new class of ultraviolet dosimeters is made possible by exposing caged dye molecules, which generate a dye molecule on exposure to ultraviolet radiation, to an exterior environment. Applications include sunburn monitors, characterizing the UV exposure history of UV-sensitive materials, especially including structural plastics, and use in disposable `one-use` optical equipment, especially medical devices.

  9. Angular response characterization of the Martin Marietta Energy Systems, Inc., personnel dosimeter

    SciTech Connect

    Ahmed, A.B.; McMahan, K.L.; Colwell, D.S.

    1993-08-01

    An evaluation of the Martin Marietta Energy Systems, Inc., personnel dosimeter to radiation incident from non-perpendicular angles was carried out to meet the Department of Energy Laboratory Accreditation Program (DOELAP) requirements. Dosimeters were exposed to six different radiation sources. For each source, dosimeters were rotated about their horizontal and vertical axes at seven different angles each. Raw readings were processed through the dose calculation algorithm used for routine personnel dosimetry to determine dose equivalent values. Dose equivalent responses relative to zero degree incident angle were found to be within {plus_minus} 20% for M150, K-59 and {sup 137}Cs photons when the incident angle was 60{degree} or less. For low-energy photon irradiations (M30 and K-16), responses for angles other than perpendicular incidence are generally unpredictable. Reasons include: (1) failure of dose calculation algorithm to identify the radiation field correctly due to unusual element ratios; and (2) at extreme angles ({plus_minus} 85{degree}), the dosimeter design (in relation to the irradiation geometry) becomes the limiting factor in producing reproducible results. Response to {sup 204}Tl beta particles decreases rapidly with increasing angle of incidence.

  10. Considerations in the application of the electronic dosimeter to dose of record

    SciTech Connect

    Swinth, K.L.

    1997-12-01

    This report describes considerations for application of the electronic dosimeter (ED) as a measurement device for the dose of record (primary dosimetry). EDs are widely used for secondary dosimetry and advances in their reliability and capabilities have resulted in interest in their use to meet the needs of both primary and secondary dosimetry. However, the ED is an active device and more complex than the thermoluminescent and film dosimeters now in use for primary dosimetry. The user must evaluate the ED in terms of reliability, serviceability and radiations detected its intended application(s). If an ED is selected for primary dosimetry, the user must establish methods both for controlling the performance of the ED to ensure long term reliability of the measurements and for their proper use as a primary dosimeter. Regulatory groups may also want to develop methods to ensure adequate performance of the ED for dose of record. The purpose of the report is to provide an overview of considerations in the use of the ED for primary dosimetry. Considerations include recognizing current limitations, type testing of EDs, testing by the user, approval performance testing, calibration, and procedures to integrate the dosimeter into the users program.

  11. Area Monitoring Dosimeter Program for the Pacific Northwest National Laboratory: Results for CY 1999

    SciTech Connect

    Bivins, Steven R.; Stoetzel, Gregory A.

    2000-09-19

    In January 1993, PNNL established an area monitoring dosimeter program in accordance with Article 514 of the DOE Radiological Control Manual. This program was to minimize the number of areas requiring issuance of personnel dosimeters and to demonstrate that doses outside Radiological Buffer Areas are negligible. In accordance with 10 CFR Part 835.402 (a)(1)-(4) and Article 511.1 of the DOE Standard Radiological Control, personnel dosimetry shall be provided to 1) radiological workers who are likely to receive at least 100 mrem annually and 2) declared pregnant workers, minors, and members of the public who are likely to receive at least 50 mrem annually. Program results for calendar years 1993-1998 confirmed that personnel dosimetry was not needed for individuals located in areas monitored by the program. A total of 123 area thermoluminescent dosimeters (TLDs) were placed in PNNL facilities during calendar year 1999. The TLDs were exchanged and analyzed quarterly. All routine area monitoring TLD results were less than 50 mrem annually after correcting for worker occupancy. The results support the conclusion that personnel dosimeters are not necessary for staff, declared pregnant workers, minors, or members of the public in these monitored areas.

  12. X-ray microbeam measurements with a high resolution scintillator fibre-optic dosimeter.

    PubMed

    Archer, James; Li, Enbang; Petasecca, Marco; Dipuglia, Andrew; Cameron, Matthew; Stevenson, Andrew; Hall, Chris; Hausermann, Daniel; Rosenfeld, Anatoly; Lerch, Michael

    2017-09-29

    Synchrotron microbeam radiation therapy is a novel external beam therapy under investigation, that uses highly brilliant synchrotron x-rays in microbeams 50 μm width, with separation of 400 μm, as implemented here. Due to the fine spatial fractionation dosimetry of these beams is a challenging and complicated problem. In this proof-of-concept work, we present a fibre optic dosimeter that uses plastic scintillator as the radiation conversion material. We claim an ideal one-dimensional resolution of 50 μm. Using plastic scintillator and fibre optic makes this dosimeter water-equivalent, a very desirable dosimetric property. The dosimeter was tested at the Australian Synchrotron, on the Imaging and Medical Beam-Line. The individual microbeams were able to be resolved and the peak-to-valley dose ratio and the full width at half maximum of the microbeams was measured. These results are compared to a semiconductor strip detector of the same spatial resolution. A percent depth dose was measured and compared to data acquired by an ionisation chamber. The results presented demonstrate significant steps towards the development of an optical dosimeter with the potential to be applied in quality assurance of microbeam radiation therapy, which is vital if clinical trials are to be performed on human patients.

  13. The effects of squalene on the PMMA dosimeter: focusing on a ``chronodosimeter''

    NASA Astrophysics Data System (ADS)

    Duroux, J. L.; Trihi, M.; Hyvernaud, M. J.; Bernard, M.

    1996-02-01

    A polymethylmethacrylate-based plastic material doped with squalene according to our laboratory protocol, has been tested by spectrophotometric measurements as a dosimeter of γ-radiation. The spectrophotometric characterization shows responses in time of which the modelization allows us to find the duration separating the irradiation and the measurement.

  14. The dose response of normoxic polymer gel dosimeters measured using X-ray CT.

    PubMed

    Hill, B; Venning, A; Baldock, C

    2005-07-01

    X-ray CT was used to determine the dose response of normoxic polymer gel dosimeters. Normoxic polymer gel dosimeters were manufactured and irradiated up to 150 Gy. Up to 50 CT images were acquired on a Toshiba Aquilion Multislice CT scanner using protocols for 80 kV and 135 kV to determine dose response. HU-dose sensitivity, the linear regression of data for the HU versus dose for the linear part of the curve up to 60 Gy was 0.38+/-0.07 HU Gy(-1) for 135 kV and 0.37+/-0.01 HU Gy(-1) for 80 kV. Dose resolution was found to be < 1.3 Gy for an absorbed dose range up to 70 Gy for 135 kV, similar to that measured previously for polyacrylamide gel (PAG). Although the HU-dose sensitivity was lower than that previously measured for PAG gel dosimeters it had a greater range of absorbed dose indicating that normoxic polymer gel dosimeters have potential in CT gel dosimetry.

  15. Characteristics of polyacrylamide gel with THPC and Turnbull Blue gel dosimeters evaluated using optical tomography

    NASA Astrophysics Data System (ADS)

    Pilařová (Vávrů), Kateřina; Kozubíková, Petra; Šolc, Jaroslav; Spěváček, Václav

    2014-11-01

    The purpose of this study was to compare characteristics of radiochromic gel - Turnbull Blue gel (TB gel) with polymer gel - polyacrylamide gel and tetrakis hydroxymethyl phosphonium chloride (PAGAT) using optical tomography. Both types of gels were examined in terms of dose sensitivity, dose response linearity and background value of spectrophotometric absorbance. The calibration curve was obtained for 60Co irradiation performed on Gammacell 220 at predefined gamma dose levels between 0 and 140 Gy for TBG and 0-15 Gy for PAGAT. To measure relative dose distributions from stereotactic irradiation, dosimeters were irradiated on Leksell Gamma Knife Perfexion. The cylindrical glass housings filled with gel were attached to the stereotactic frame. They were exposed with single shot and 16 mm collimator by 65 Gy to a 50% prescription isodose for TB gel and 4 Gy to a 50% prescription isodose for PAGAT. Evaluations of dosimeters were performed on an UV-vis Spectrophotometer Helios β and an optical cone beam homemade tomography scanner with a 16-bit astronomy CCD camera with a set of color filters. The advantages and potential disadvantages for both types of gel dosimeters were summarized. Dose distribution in central slice and measured profiles of 16 mm shot shows excellent correspondence with treatment planning system Leksell GammaPlan® for both PAGAT and Turnbull Blue gels. Gel dosimeters are suitable for steep dose gradient verification. An optical tomography evaluation method is successful. Dose response characteristics of TB gel and PAGAT gel are presented.

  16. SU-E-T-753: Three-Dimensional Dose Distributions of Incident Proton Particle in the Polymer Gel Dosimeter and the Radiochromic Gel Dosimeter: A Simulation Study with MCNP Code

    SciTech Connect

    Park, M; Kim, G; Ji, Y; Kim, K; Park, S; Jung, H

    2015-06-15

    Purpose: The purpose of this study is to estimate the three-dimensional dose distributions in the polymer and the radiochromic gel dosimeter, and to identify the detectability of both gel dosimeters by comparing with the water phantom in case of irradiating the proton particles. Methods: The normoxic polymer gel and the LCV micelle radiochromic gel were used in this study. The densities of polymer and the radiochromic gel dosimeter were 1.024 and 1.005 g/cm{sup 3}, respectively. The dose distributions of protons in the polymer and radiochromic gel were simulated using Monte Carlo radiation transport code (MCNPX, Los Alamos National Laboratory). The shape of phantom irradiated by proton particles was a hexahedron with the dimension of 12.4 × 12.4 × 15.0 cm{sup 3}. The energies of proton beam were 50, 80, and 140 MeV energies were directed to top of the surface of phantom. The cross-sectional view of proton dose distribution in both gel dosimeters was estimated with the water phantom and evaluated by the gamma evaluation method. In addition, the absorbed dose(Gy) was also calculated for evaluating the proton detectability. Results: The evaluation results show that dose distributions in both gel dosimeters at intermediated section and Bragg-peak region are similar with that of the water phantom. At entrance section, however, inconsistencies of dose distribution are represented, compared with water. The relative absorbed doses in radiochromic and polymer gel dosimeter were represented to be 0.47 % and 2.26 % difference, respectively. These results show that the radiochromic gel dosimeter was better matched than the water phantom in the absorbed dose evaluation. Conclusion: The polymer and the radiochromic gel dosimeter show similar characteristics in dose distributions for the proton beams at intermediate section and Bragg-peak region. Moreover the calculated absorbed dose in both gel dosimeters represents similar tendency by comparing with that in water phantom.

  17. Effects of refractive index mismatch in optical CT imaging of polymer gel dosimeters

    SciTech Connect

    Manjappa, Rakesh; Makki S, Sharath; Kanhirodan, Rajan; Kumar, Rajesh

    2015-02-15

    Purpose: Proposing an image reconstruction technique, algebraic reconstruction technique-refraction correction (ART-rc). The proposed method takes care of refractive index mismatches present in gel dosimeter scanner at the boundary, and also corrects for the interior ray refraction. Polymer gel dosimeters with high dose regions have higher refractive index and optical density compared to the background medium, these changes in refractive index at high dose results in interior ray bending. Methods: The inclusion of the effects of refraction is an important step in reconstruction of optical density in gel dosimeters. The proposed ray tracing algorithm models the interior multiple refraction at the inhomogeneities. Jacob’s ray tracing algorithm has been modified to calculate the pathlengths of the ray that traverses through the higher dose regions. The algorithm computes the length of the ray in each pixel along its path and is used as the weight matrix. Algebraic reconstruction technique and pixel based reconstruction algorithms are used for solving the reconstruction problem. The proposed method is tested with numerical phantoms for various noise levels. The experimental dosimetric results are also presented. Results: The results show that the proposed scheme ART-rc is able to reconstruct optical density inside the dosimeter better than the results obtained using filtered backprojection and conventional algebraic reconstruction approaches. The quantitative improvement using ART-rc is evaluated using gamma-index. The refraction errors due to regions of different refractive indices are discussed. The effects of modeling of interior refraction in the dose region are presented. Conclusions: The errors propagated due to multiple refraction effects have been modeled and the improvements in reconstruction using proposed model is presented. The refractive index of the dosimeter has a mismatch with the surrounding medium (for dry air or water scanning). The algorithm

  18. Remote auditing of radiotherapy facilities using optically stimulated luminescence dosimeters

    SciTech Connect

    Lye, Jessica Dunn, Leon; Kenny, John; Alves, Andrew; Lehmann, Joerg; Williams, Ivan; Kron, Tomas; Oliver, Chris; Butler, Duncan; Johnston, Peter; Franich, Rick

    2014-03-15

    Purpose: On 1 July 2012, the Australian Clinical Dosimetry Service (ACDS) released its Optically Stimulated Luminescent Dosimeter (OSLD) Level I audit, replacing the previous TLD based audit. The aim of this work is to present the results from this new service and the complete uncertainty analysis on which the audit tolerances are based. Methods: The audit release was preceded by a rigorous evaluation of the InLight® nanoDot OSLD system from Landauer (Landauer, Inc., Glenwood, IL). Energy dependence, signal fading from multiple irradiations, batch variation, reader variation, and dose response factors were identified and quantified for each individual OSLD. The detectors are mailed to the facility in small PMMA blocks, based on the design of the existing Radiological Physics Centre audit. Modeling and measurement were used to determine a factor that could convert the dose measured in the PMMA block, to dose in water for the facility's reference conditions. This factor is dependent on the beam spectrum. The TPR{sub 20,10} was used as the beam quality index to determine the specific block factor for a beam being audited. The audit tolerance was defined using a rigorous uncertainty calculation. The audit outcome is then determined using a scientifically based two tiered action level approach. Audit outcomes within two standard deviations were defined as Pass (Optimal Level), within three standard deviations as Pass (Action Level), and outside of three standard deviations the outcome is Fail (Out of Tolerance). Results: To-date the ACDS has audited 108 photon beams with TLD and 162 photon beams with OSLD. The TLD audit results had an average deviation from ACDS of 0.0% and a standard deviation of 1.8%. The OSLD audit results had an average deviation of −0.2% and a standard deviation of 1.4%. The relative combined standard uncertainty was calculated to be 1.3% (1σ). Pass (Optimal Level) was reduced to ≤2.6% (2σ), and Fail (Out of Tolerance) was reduced to >3

  19. Solid-state dosimeters: A new approach for mammography measurements

    SciTech Connect

    Brateman, Libby F.; Heintz, Philip H.

    2015-02-15

    Purpose: To compare responses of modern commercially available solid-state dosimeters (SStDs) used in mammography medical physics surveys for two major vendors of current digital mammography units. To compare differences in dose estimates among SStD responses with ionization chamber (IC) measurements for several target/filter (TF) combinations and report their characteristics. To review scientific bases for measurements of quantities required for mammography for traditional measurement procedures and SStDs. Methods: SStDs designed for use with modern digital mammography units were acquired for evaluation from four manufacturers. Each instrument was evaluated under similar conditions with the available mammography beams provided by two modern full-field digital mammography units in clinical use: a GE Healthcare Senographe Essential (Essential) and a Hologic Selenia Dimensions 5000 (Dimensions), with TFs of Mo/Mo, Mo/Rh; and Rh/Rh and W/Rh, W/Ag, and W/Al, respectively. Measurements were compared among the instruments for the TFs over their respective clinical ranges of peak tube potentials for kVp and half-value layer (HVL) measurements. Comparisons for air kerma (AK) and their associated relative calculated average glandular doses (AGDs), i.e., using fixed mAs, were evaluated over the limited range of 28–30 kVp. Measurements were compared with reference IC measurements for AK, reference HVLs and calculated AGD, for two compression paddle heights for AK, to evaluate scatter effects from compression paddles. SStDs may require different positioning from current mammography measurement protocols. Results: Measurements of kVp were accurate in general for the SStDs (within −1.2 and +1.1 kVp) for all instruments over a wide range of set kVp’s and TFs and most accurate for Mo/Mo and W/Rh. Discrepancies between measurements and reference values were greater for HVL and AK. Measured HVL values differed from reference values by −6.5% to +3.5% depending on the SStD and

  20. Determining the applicability of the Landauer nanoDot as a general public dosimeter in a research imaging facility.

    PubMed

    Charlton, Michael A; Thoreson, Kelly F; Cerecero, Jennifer A

    2012-11-01

    The Research Imaging Institute (RII) building at the University of Texas Health Science Center at San Antonio (UTHSCSA) houses two cyclotron particle accelerators, positron emission tomography (PET) machines, and a fluoroscopic unit. As part of the radiation protection program (RPP) and meeting the standard for achieving ALARA (as low as reasonably achievable), it is essential to minimize the ionizing radiation exposure to the general public through the use of controlled areas and area dose monitoring. Currently, thirty-four whole body Luxel+ dosimeters, manufactured by Landauer, are being used in various locations within the RII to monitor dose to the general public. The intent of this research was to determine if the nanoDot, a single point dosimeter, can be used as a general public dosimeter in a diagnostic facility. This was tested by first verifying characteristics of the nanoDot dosimeter including dose linearity, dose rate dependence, angular dependence, and energy dependence. Then, the response of the nanoDot dosimeter to the Luxel+ dosimeter when placed in a continuous, low dose environment was investigated. Finally, the nanoDot was checked for appropriate response in an acute, high dose environment. Based on the results, the current recommendation is that the nanoDot should not replace the Luxel+ dosimeter without further work to determine the energy spectra in the RII building and without considering the limitation of the microStar reader, portable on-site OSL reader, at doses below 0.1 mGy (10 mrad).

  1. Characteristics of a novel polymer gel dosimeter formula for MRI scanning: Dosimetry, toxicity and temporal stability of response.

    PubMed

    Abtahi, S M

    2016-09-01

    The present study intended to investigate the composition of a new polymer gel dosimeter. The new composition would be more suitable for a wide range of applications in comparison to polyacrylamide gel dosimeter since its extremely toxic acrylamide has been replaced with less harmful monomer i.e. 2-Acrylamido-2-MethylPropane Sulfonic acid (AMPS). To this end, the PAGAT gel dosimeter formula was used as a basis to test the new formulation of polymer gel dosimeter with a different monomer (AMPS) instead of acrylamide by using the %6T and %50C to the formula. The new formulation was named PAMPSGAT (Poly AMPS, Gelatin and THPC) polymer gel dosimeter. Moreover, the MRI response (R2) of dosimeters was analyzed in terms of different dose range as well as post-irradiation time. The results indicated that the dose-response (R2) of AMPS/Bis had a linear trend over a wide dose range. Furthermore, the results showed an acceptable temporal stability for the new polymer gel dosimeter.

  2. Temperature and temporal dependence of the optical response for a radiochromic dosimeter

    SciTech Connect

    Skyt, Peter S.; Wahlstedt, Isak; Muren, Ludvig P.; Petersen, Jorgen B. B.; Balling, Peter

    2012-12-15

    Purpose: Both temporal and thermal dependencies of the dose response have been observed in radiochromic dosimeters. As these dependencies may be influenced by the dose level, the present study investigates the temperature dependence during irradiation and the temporal change of the optical response following irradiation of radiochromic dosimeters at a range of doses. Methods: Cuvette samples of the PRESAGE Trade-Mark-Sign radiochromic dosimeter were irradiated within a dose range of 0-10 Gy at irradiation temperatures within 5-35 Degree-Sign C and postirradiation storage within 6-30 Degree-Sign C. The optical response due to irradiation was measured using a standard spectrophotometer and the data were analyzed in terms of thermal and temporal change. Results: The initial dose response was linear over the applied dose range independent of irradiation temperature. However, the optical response to a specific dose increased exponentially with irradiation temperature corresponding to an activation energy of 0.114 {+-} 0.007 eV. The temporal change in dose response after irradiation consisted of an offset, an auto-oxidation rate with activation energy 0.84 {+-} 0.03 eV, and an initial exponential increase in optical response (1.6 {+-} 0.2 eV) followed by an exponential decrease in optical response (0.98 {+-} 0.08 eV). These contributions depended on both storage temperature and the dose given, leading to a nonlinear dose response with time at low storage temperatures and a high auto-oxidation rate at high storage temperatures. Conclusions: Thermal equilibration is important to the radiochromic dosimeter investigated due to an exponential change in dose response with irradiation temperature and a considerable postirradiation temporal change in response. For the dosimeter version investigated in this study, a compromise in storage temperature has to be made between increasing the nonlinearity of the dose response with time and inducing a high auto-oxidation rate.

  3. An optically stimulated luminescence dosimeter for measuring patient exposure from imaging guidance procedures.

    PubMed

    Ding, George X; Malcolm, Arnold W

    2013-09-07

    There is a growing interest in patient exposure resulting from an x-ray imaging procedure used in image-guided radiation therapy. This study explores a feasibility to use a commercially available optically stimulated luminescence (OSL) dosimeter, nanoDot, for estimating imaging radiation exposure to patients. The kilovoltage x-ray sources used for kV-cone-beam CT (CBCT) imaging acquisition procedures were from a Varian on-board imager (OBI) image system. An ionization chamber was used to determine the energy response of nanoDot dosimeters. The chamber calibration factors for x-ray beam quality specified by half-value layer were obtained from an Accredited Dosimetry Calibration Laboratory. The Monte Carlo calculated dose distributions were used to validate the dose distributions measured by using the nanoDot dosimeters in phantom and in vivo. The range of the energy correction factors for the nanoDot as a function of photon energy and bow-tie filters was found to be 0.88-1.13 for different kVp and bow-tie filters. Measurement uncertainties of nanoDot were approximately 2-4% after applying the energy correction factors. The tests of nanoDot placed on a RANDO phantom and on patient's skin showed consistent results. The nanoDot is suitable dosimeter for in vivo dosimetry due to its small size and manageable energy dependence. The dosimeter placed on a patient's skin has potential to serve as an experimental method to monitor and to estimate patient exposure resulting from a kilovoltage x-ray imaging procedure. Due to its large variation in energy response, nanoDot is not suitable to measure radiation doses resulting from mixed beams of megavoltage therapeutic and kilovoltage imaging radiations.

  4. Water-equivalent dosimeter array for small-field external beam radiotherapy

    SciTech Connect

    Archambault, Louis; Beddar, A. Sam; Gingras, Luc; Lacroix, Frederic; Roy, Rene; Beaulieu, Luc

    2007-05-15

    With the increasing complexity of dose patterns external beam radiotherapy, there is a great need for new types of dosimeters. We studied the first prototype of a new dosimeter array consisting of water-equivalent plastic scintillating fibers for dose measurement in external beam radiotherapy. We found that this array allows precise, rapid dose evaluation of small photon fields. Starting with a dosimeter system constructed with a single scintillating fiber coupled to a clear optical fiber and read using a charge coupled device camera, we looked at the dosimeter's spatial resolution under small radiation fields and angular dependence. Afterward, we analyzed the camera's light collection to determine the maximum array size that could be built. Finally, we developed a prototype made of ten scintillating fiber detectors to study the behavior and precision of this system in simple dosimetric situations. The scintillation detector showed no measurable angular dependence. Comparison of the scintillation detector and a small-volume ion chamber showed agreement except for 1x1 and 0.5x5.0 cm{sup 2} fields where the output factor measured by the scintillator was higher. The actual field of view of the camera could accept more than 4000 scintillating fiber detectors simultaneously. Evaluation of the dose profile and depth dose curve using a prototype with ten scintillating fiber detectors showed precise, rapid dose evaluation even with placement of more than 75 optical fibers in the field to simulate what would happen in a larger array. We concluded that this scintillating fiber dosimeter array is a valuable tool for dose measurement in external beam radiotherapy. It possesses the qualities necessary to evaluate small and irregular fields with various incident angles such as those encountered in intensity-modulated radiotherapy, radiosurgery, and tomotherapy.

  5. Dose evaluation of an NIPAM polymer gel dosimeter using gamma index

    NASA Astrophysics Data System (ADS)

    Chang, Yuan-Jen; Lin, Jing-Quan; Hsieh, Bor-Tsung; Yao, Chun-Hsu; Chen, Chin-Hsing

    2014-11-01

    An N-isopropylacrylamide (NIPAM) polymer gel dosimeter has great potential in clinical applications. However, its three-dimensional dose distribution must be assessed. In this work, a quantitative evaluation of dose distributions was performed to evaluate the NIPAM polymer gel dosimeter using gamma analysis. A cylindrical acrylic phantom filled with NIPAM gel measuring 10 cm (diameter) by 10 cm (height) by 3 mm (thickness) was irradiated by a 4×4 cm2 square light field. The irradiated gel phantom was scanned using an optical computed tomography (optical CT) scanner (OCTOPUS™, MGS Research, Inc., Madison, CT, USA) at 1 mm resolution. The projection data were transferred to an image reconstruction program, which was written using MATLAB (The MathWorks, Natick, MA, USA). The program reconstructed the image of the optical density distribution using the algorithm of a filter back-projection. Three batches of replicated gel phantoms were independently measured. The average uncertainty of the measurements was less than 1%. The gel was found to have a high degree of spatial uniformity throughout the dosimeter and good temporal stability. A comparison of the line profiles of the treatment planning system and of the data measured by optical CT showed that the dose was overestimated in the penumbra region because of two factors. The first is light scattering due to changes in the refractive index at the edge of the irradiated field. The second is the edge enhancement caused by free radical diffusion. However, the effect of edge enhancement on the NIPAM gel dosimeter is not as significant as that on the BANG gel dosimeter. Moreover, the dose uncertainty is affected by the inaccuracy of the gel container positioning process. To reduce the uncertainty of 3D dose distribution, improvements in the gel container holder must be developed.

  6. Application of a radiophotoluminescent glass plate dosimeter for small field dosimetry.

    PubMed

    Aaki, Fujio; Ishidoya, Tatsuya; Ikegami, Tohru; Moribe, Nobuyuki; Yamashita, Yasuyuki

    2005-06-01

    We have recently developed a prototypical radiophotoluminescent glass plate dosimeter (GPD) system as a device for small field dosimetry. The purpose of this study is to examine the usefulness of the GPD system for small field dosimetry. The profiles measured with the GPD were evaluated by comparing them to those from Kodak X-Omat V and GAFCROMIC XR type R film dosimeters for 2, 5, 9, and 15 mm circular collimators created by a linear accelerator-based radiosurgery system. The GPD output factors were compared with those of various detectors including an ion chamber, a p-type silicon diode detector, a glass rod dosimeter (GRD), and a diamond detector. The results measured with the GPD were also confirmed by comparing them to those from Monte Carlo simulations. The accuracy of a simulated beam is validated by the excellent agreement between Monte Carlo calculated and measured central axis depth-dose curves for 9- and 15 mm circular collimators using 4- and 10 MV photon beams. The GPD profiles show almost the same full width at half maximum as those of film dosimeters and Monte Carlo simulations at 4- and 10 MV photon beams, but a little narrower penumbrae than the film dosimeters and Monte Carlo simulations. The output factors measured with the GPD are in good agreement with those from a diode detector, a diamond detector, and the GRD with a small active volume and Monte Carlo simulations, except for a very small 2 mm circular collimator. It was found that the GPD is a very useful detector for small field dosimetry.

  7. Commissioning optically stimulated luminescence in vivo dosimeters for fast neutron therapy

    SciTech Connect

    Young, Lori A. Sandison, George; Yang, Fei; Woodworth, Davis; McCormick, Zephyr

    2016-01-15

    Purpose: Clinical in vivo dosimeters intended for use with photon and electron therapies have not been utilized for fast neutron therapy because they are highly susceptible to neutron damage. The objective of this work was to determine if a commercial optically stimulated luminescence (OSL) in vivo dosimetry system could be adapted for use in fast neutron therapy. Methods: A 50.5 MeV fast neutron beam generated by a clinical neutron therapy cyclotron was used to irradiate carbon doped aluminum oxide (Al{sub 2}O{sub 3}:C) optically simulated luminescence dosimeters (OSLDs) in a solid water phantom under standard calibration conditions, 150 cm SAD, 1.7 cm depth, and 10.3 × 10.0 cm field size. OSLD fading and electron trap depletion studies were performed with the OSLDs irradiated with 20 and 50 cGy and monitored over a 24-h period to determine the optimal time for reading the dosimeters during calibration. Four OSLDs per group were calibrated over a clinical dose range of 0–150 cGy. Results: OSLD measurement uncertainties were lowered to within ±2%–3% of the expected dose by minimizing the effect of transient fading that occurs with neutron irradiation and maintaining individual calibration factors for each dosimeter. Dose dependent luminescence fading extended beyond the manufacturer’s recommended 10 min period for irradiation with photon or electron beams. To minimize OSL variances caused by inconsistent fading among dosimeters, the observed optimal time for reading the OSLDs postirradiation was between 30 and 90 min. No field size, wedge factor, or gantry angle dependencies were observed in the OSLDs irradiated by the studied fast neutron beam. Conclusions: Measurements demonstrated that uncertainties less than ±3% were attainable in OSLDs irradiated with fast neutrons under clinical conditions. Accuracy and precision comparable to clinical OSL measurements observed with photons can be achieved by maintaining individual OSLD calibration factors and

  8. Correcting the Response of an Albedo Neutron Dosimeter for Energy

    DTIC Science & Technology

    2007-01-01

    detectors; thermoluminescent dosemeters (TLDs), neutron, energy 16. SECURITY CLASSIFICATION OF: 19a. NAME OF RESPONSIBLE PERSON Dr. Gordon K. Riel a... Thermoluminescent Dosemeters (TLD).......................................................................................... 1 Detectors for Energy...SSBN ballistic missile submarine TLD thermoluminescent dosemeter USNA United States Naval Academy NSWCCD-63-TR–2006/36 1 Introduction The

  9. A comprehensive study on the photon energy response of RadFET dosimeters using the PENELOPE Monte Carlo code

    NASA Astrophysics Data System (ADS)

    Kahraman, A.; Kaya, S.; Jaksic, A.; Yilmaz, E.

    2015-05-01

    Radiation-sensing Field Effect Transistors (RadFETs or MOSFET dosimeters) with SiO2 gate dielectric have found applications in space, radiotherapy clinics, and high-energy physics laboratories. More sensitive RadFETs, which require modifications in device design, including gate dielectric, are being considered for personal dosimetry applications. This paper presents results of a detailed study of the RadFET energy response simulated with PENELOPE Monte Carlo code. Alternative materials to SiO2 were investigated to develop high-efficiency new radiation sensors. Namely, in addition to SiO2, Al2O3 and HfO2 were simulated as gate material and deposited energy amounts in these layers were determined for photon irradiation with energies between 20 keV and 5 MeV. The simulations were performed for capped and uncapped configurations of devices irradiated by point and extended sources, the surface area of which is the same with that of the RadFETs. Energy distributions of transmitted and backscattered photons were estimated using impact detectors to provide information about particle fluxes within the geometrical structures. The absorbed energy values in the RadFETs material zones were recorded. For photons with low and medium energies, the physical processes that affect the absorbed energy values in different gate materials are discussed on the basis of modelling results. The results show that HfO2 is the most promising of the simulated gate materials.

  10. Evaluation of LLNL's Nuclear Accident Dosimeters at the CALIBAN Reactor September 2010

    SciTech Connect

    Hickman, D P; Wysong, A R; Heinrichs, D P; Wong, C T; Merritt, M J; Topper, J D; Gressmann, F A; Madden, D J

    2011-06-21

    The Lawrence Livermore National Laboratory uses neutron activation elements in a Panasonic TLD holder as a personnel nuclear accident dosimeter (PNAD). The LLNL PNAD has periodically been tested using a Cf-252 neutron source, however until 2009, it was more than 25 years since the PNAD has been tested against a source of neutrons that arise from a reactor generated neutron spectrum that simulates a criticality. In October 2009, LLNL participated in an intercomparison of nuclear accident dosimeters at the CEA Valduc Silene reactor (Hickman, et.al. 2010). In September 2010, LLNL participated in a second intercomparison of nuclear accident dosimeters at CEA Valduc. The reactor generated neutron irradiations for the 2010 exercise were performed at the Caliban reactor. The Caliban results are described in this report. The procedure for measuring the nuclear accident dosimeters in the event of an accident has a solid foundation based on many experimental results and comparisons. The entire process, from receiving the activated NADs to collecting and storing them after counting was executed successfully in a field based operation. Under normal conditions at LLNL, detectors are ready and available 24/7 to perform the necessary measurement of nuclear accident components. Likewise LLNL maintains processing laboratories that are separated from the areas where measurements occur, but contained within the same facility for easy movement from processing area to measurement area. In the event of a loss of LLNL permanent facilities, the Caliban and previous Silene exercises have demonstrated that LLNL can establish field operations that will very good nuclear accident dosimetry results. There are still several aspects of LLNL's nuclear accident dosimetry program that have not been tested or confirmed. For instance, LLNL's method for using of biological samples (blood and hair) has not been verified since the method was first developed in the 1980's. Because LLNL and the other DOE

  11. Development of an Automated Reader for Analysis and Storage of Personnel Dosimeter Badge Data

    NASA Technical Reports Server (NTRS)

    Meneghelli, B. J.; Hodge, T. R.; Robinson, L. J.; Lueck, D. E.

    1997-01-01

    The collection and archiving of data from personnel dosimeters has become increasingly important in light of the lowered Threshold Limit Values (TLV) for HydraZine (HZ), MonoMethylHydrazine (MMH), and Unsymmetrical DiMethylHydrazine (UDMH). The American Conference of Government Industrial Hygienists (ACGIH) lowered the TLV from 100 parts per billion (ppb) to IO ppb and has caused increased concern over long term exposures of personnel to trace levels of these hypergols and other potentially harmful chemicals. An automated system of reading the exposure levels of personnel dosimeters and storing exposure data for subsequent evaluation has been developed. The reading of personnel dosimeter badges for exposure to potentially harmful vapor concentrations of hydrazines or other chemicals is performed visually by comparing the color developed by the badge with a calibrated color comparator. The result obtained using visual comparisons of the developed badge color with the comparator may vary widely from user to user. The automated badge reader takes the variability out of the dosimeter reading by accurately comparing the reflectance obtained from a colored spot on the badge with a reading on the same spot prior to any exposure to chemical vapors. The observed difference between the reflectance values is used as part of a calculation of the dose value for the badge based on a stored calibration curve. The badge reader also stores bar-code data unique to each badge, as well as bar-code information on the user, as part of the permanent badge record. The start and stop exposure times for each badge are recorded and can be used as part of the calculated concentration, in ppm, for each badge logged during a recording period. The badge reader is equipped with a number of badge holders, each of which is unique to a specific type of personnel dosimeter badge. This gives the reader maximum flexibility to allow for the reading of several different types of badges. Test results of

  12. Multifactorial study and kinetics of signal development in ferrous-methylthymol blue-gelatin gel dosimeters.

    PubMed

    Penev, Kalin I; Mequanint, Kibret

    2017-05-01

    To develop and characterize a ferrous-methylthymol blue-gelatin gel dosimeter with low optical background and appropriate additives for reduced rate of auto-oxidation and diffusion. A mixed-level multifactorial design of experiments was used to test the effects of the concentrations of sulfuric acid, 5-nitro-1,10-phenanthroline (Nn), and glyoxal (Gx) on the background absorbance, dose sensitivity, and auto-oxidation of the tested gel dosimeter. The dosimetric properties of the proposed ferrous-methylthymol blue-gelatin dosimeter, doped with Nn and Gx, were compared with the undoped formulation and with ferrous-xylenol orange-gelatin gel dosimeters. Irradiations were performed in both small-scale cuvette samples and large 400-mL bulk samples. In addition to that, a new kinetic model for the signal development postirradiation was derived based on chemical principles and used for comparison of the different formulations. The new formulation showed a reduced auto-oxidation rate, while maintaining low background absorbance relative to the common ferrous-xylenol orange-gelatin gel dosimeter. Compared with undoped ferrous-xylenol orange or ferrous-methylthymol blue gels, the dose sensitivity of the new formulation is approximately 2 to 3 times lower, but remains clinically adequate. A previously unreported dose rate dependence of the dose sensitivity was observed, and a new kinetic model for the signal development postirradiation was used to investigate this effect. Similar dose rate dependences in gels containing either methylthymol blue or xylenol orange, with or without doping with Nn and Gx, were observed, suggesting that the low ferrous ammonium sulfate concentrations used in studied formulations were responsible for this effect. A multifactorial design of experiments and a new kinetic model for the signal development postirradiation were successfully employed to optimize the composition and characterize the properties of a new ferrous-methylthymol blue-gelatin gel

  13. Development of an Automated Reader for Analysis and Storage of Personnel Dosimeter Badge Data

    NASA Technical Reports Server (NTRS)

    Meneghelli, B. J.; Hodge, T. R.; Robinson, L. J.; Lueck, D. E.

    1997-01-01

    The collection and archiving of data from personnel dosimeters has become increasingly important in light of the lowered threshold limit values (TLV) for hydrazine (HZ), monomethylhydrazine (MMH), and unsymmetrical dimethylhydrazine (UDMH). The American Conference of Government Industrial Hygienists (ACGIH) lowered the TLV from 100 parts per billion (ppb) to 10 ppb and has caused increased concern over long term exposures of personnel to trace levels of these hypergols and other potentially harmful chemicals. An automated system of reading the exposure levels of personnel dosimeters and storing exposure data for subsequent evaluation has been developed. The reading of personnel dosimeter badges for exposure lo potentially harmful vapor concentrations of hydrazines or other chemicals is performed visually by comparing the color developed by the badge with a calibrated color comparator. The result obtained using visual comparisons of the developed badge color with the comparator may vary widely from user to user. The automated badge reader takes the variability out of the dosimeter reading by accurately comparing the reflectance obtained from a colored spot on the badge with a reading on the same spot prior to any exposure to chemical vapors. The observed difference between the reflectance values is used as part of a calculation of the dose value for the badge based on a stored calibration curve. The badge reader also stores bar-code data unique to each badge, as well as bar-code information on the user, as part of the permanent badge record. The start and stop exposure times for each badge are recorded and can be used as part of the calculated concentration, in ppm, for each badge logged during a recording period. The badge reader is equipped with a number of badge holders, each of which is unique to a specific type of personnel dosimeter badge. This gives the reader maximum flexibility to allow for the reading of several different types of badges. Test results of

  14. Estimating dose to implantable cardioverter-defibrillator outside the treatment fields using a skin QED diode, optically stimulated luminescent dosimeters, and LiF thermoluminescent dosimeters

    SciTech Connect

    Chan, Maria F.; Song, Yulin; Dauer, Lawrence T.; Li Jingdong; Huang, David; Burman, Chandra

    2012-10-01

    The purpose of this work was to determine the relative sensitivity of skin QED diodes, optically stimulated luminescent dosimeters (OSLDs) (microStar Trade-Mark-Sign DOT, Landauer), and LiF thermoluminescent dosimeters (TLDs) as a function of distance from a photon beam field edge when applied to measure dose at out-of-field points. These detectors have been used to estimate radiation dose to patients' implantable cardioverter-defibrillators (ICDs) located outside the treatment field. The ICDs have a thin outer case made of 0.4- to 0.6-mm-thick titanium ({approx}2.4-mm tissue equivalent). A 5-mm bolus, being the equivalent depth of the devices under the patient's skin, was placed over the ICDs. Response per unit absorbed dose-to-water was measured for each of the dosimeters with and without bolus on the beam central axis (CAX) and at a distance up to 20 cm from the CAX. Doses were measured with an ionization chamber at various depths for 6- and 15-MV x-rays on a Varian Clinac-iX linear accelerator. Relative sensitivity of the detectors was determined as the ratio of the sensitivity at each off-axis distance to that at the CAX. The detector sensitivity as a function of the distance from the field edge changed by {+-} 3% (1-11%) for LiF TLD-700, decreased by 10% (5-21%) for OSLD, and increased by 16% (11-19%) for the skin QED diode (Sun Nuclear Corp.) at the equivalent depth of 5 mm for 6- or 15-MV photon energies. Our results showed that the use of bolus with proper thickness (i.e., {approx}d{sub max} of the photon energy) on the top of the ICD would reduce the scattered dose to a lower level. Dosimeters should be calibrated out-of-field and preferably with bolus equal in thickness to the depth of interest. This can be readily performed in clinic.

  15. Estimating dose to implantable cardioverter-defibrillator outside the treatment fields using a skin QED diode, optically stimulated luminescent dosimeters, and LiF thermoluminescent dosimeters.

    PubMed

    Chan, Maria F; Song, Yulin; Dauer, Lawrence T; Li, Jingdong; Huang, David; Burman, Chandra

    2012-01-01

    The purpose of this work was to determine the relative sensitivity of skin QED diodes, optically stimulated luminescent dosimeters (OSLDs) (microStar™ DOT, Landauer), and LiF thermoluminescent dosimeters (TLDs) as a function of distance from a photon beam field edge when applied to measure dose at out-of-field points. These detectors have been used to estimate radiation dose to patients' implantable cardioverter-defibrillators (ICDs) located outside the treatment field. The ICDs have a thin outer case made of 0.4- to 0.6-mm-thick titanium (∼2.4-mm tissue equivalent). A 5-mm bolus, being the equivalent depth of the devices under the patient's skin, was placed over the ICDs. Response per unit absorbed dose-to-water was measured for each of the dosimeters with and without bolus on the beam central axis (CAX) and at a distance up to 20 cm from the CAX. Doses were measured with an ionization chamber at various depths for 6- and 15-MV x-rays on a Varian Clinac-iX linear accelerator. Relative sensitivity of the detectors was determined as the ratio of the sensitivity at each off-axis distance to that at the CAX. The detector sensitivity as a function of the distance from the field edge changed by ± 3% (1-11%) for LiF TLD-700, decreased by 10% (5-21%) for OSLD, and increased by 16% (11-19%) for the skin QED diode (Sun Nuclear Corp.) at the equivalent depth of 5 mm for 6- or 15-MV photon energies. Our results showed that the use of bolus with proper thickness (i.e., ∼d(max) of the photon energy) on the top of the ICD would reduce the scattered dose to a lower level. Dosimeters should be calibrated out-of-field and preferably with bolus equal in thickness to the depth of interest. This can be readily performed in clinic. Copyright © 2012 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  16. Investigation of unstabilized polyvinyl chloride (PVC) for use as a long-term UV dosimeter: preliminary results

    NASA Astrophysics Data System (ADS)

    Amar, Abdurazaq; Parisi, Alfio V.

    2012-08-01

    A new chemical UV dosimeter with a larger dose capacity than existing chemical dosimeters has been investigated for long-term UV measurements. Unstabilized polyvinyl chloride (PVC), cast in 40 µm thick film, has been found to respond to at least 745 SED (Standard Erythema Dose = 100 J m-2) of solar UV radiation, which is equivalent to about two to three summer weeks of exposure in subtropical sites. The UV-induced changes in the PVC dosimeter were quantified using a Fourier transform infrared spectrophotometer and the decrease in the absorption intensity of the 1064 cm-1 peak was employed to quantify these changes. Dose response curves have been established by relating the decrease in the PVC dosimeter's absorption intensity at 1064 cm-1 to the corresponding absolute and erythemal UV exposure dose.

  17. SU-E-I-36: A Study to Compare Operator Dosimeter Exposure versus Fluoroscopic Time and Air Kerma in Fluoroscopically Guided Interventional Procedures.

    PubMed

    McKetty, M

    2012-06-01

    The total effective dose equivalent limit for occupationally radiation exposed persons has remained at 50 millisieverts per year since the 1960s. There is ongoing discussion whether this limit should be lowered. Whether or not it is lowered, all facilities have to adhere to the principle of ALARA (as low as reasonably achievable). In a hospital environment, the workers who typically have exposures which Result in ALARA investigations having to be performed include interventional radiologists, cardiologists, and mobile C-arm operators. At our institution there are a limited number of interventional radiologists with one person being responsible for performing the majority of the procedures and sometimes exceeding the ALARA investigational levels. A limited study was performed to compare the number, type of studies, cumulative air kerma, and fluoroscopic time versus the exposure measured by the personnel dosimeters worn by the radiologists. This was also related to the type of angiographic equipment in use. The length of fluoroscopic time and cumulative air kerma and cumulative DAP appeared to be related to the higher exposures received by the operator. The number of procedures performed did not correlate with the personnel dosimeter exposure; rather it was the type and complexity of a study and the length of fluoroscopic time that was related. The number of ALARA investigations required has decreased gradually. This could be attributed to several factors. These include increased use of available safety items. With an increase in the number of interventionalists the work load is distributed more equitably. The purchase of new angiographic equipment has resulted in better image quality and more shielding options for the operators. The operators are periodically reminded to keep fluoroscopic time to a minimum and use appropriate settings on the equipment. The equipment is calibrated to provide adequate image quality at mid-dose settings. © 2012 American Association of

  18. Sensitivity and variability of Presage dosimeter formulations in sheet form with application to SBRT and SRS QA.

    PubMed

    Dumas, Michael; Rakowski, Joseph T

    2015-12-01

    To measure sensitivity and stability of the Presage dosimeter in sheet form for various chemical concentrations over a range of clinical photon energies and examine its use for stereotactic body radiation therapy (SBRT) and stereotactic radiosurgery (SRS) QA. Presage polymer dosimeters were formulated to investigate and optimize their sensitivity and stability. The dosimeter is composed of clear polyurethane base, leucomalachite green (LMG) reporting dye, and bromoform radical initiator in 0.9-1.0 mm thick sheets. The chemicals are mixed together for 2 min, cast in an aluminum mold, and left to cure at 60 psi for a minimum of two days. Dosimeter response was characterized at energies Co-60, 6 MV, 10 MV flattening-filter free, 15 MV, 50 kVp (mean 19.2 keV), and Ir-192. The dosimeters were scanned by a Microtek Scanmaker i800 at 300 dpi, 2(16) bit depth per color channel. Red component images were analyzed with ImageJ and rit. SBRT QA was done with gamma analysis tolerances of 2% and 2 mm DTA. The sensitivity of the Presage dosimeter increased with increasing concentration of bromoform. Addition of tin catalyst decreased curing time and had negligible effect on sensitivity. LMG concentration should be at least as high as the bromoform, with ideal concentration being 2% wt. Gamma Knife SRS QA measurements of relative output and profile widths were within 2% of manufacturer's values validated at commissioning, except the 4 mm collimator relative output which was within 3%. The gamma pass rate of Presage with SBRT was 73.7%, compared to 93.1% for EBT2 Gafchromic film. The Presage dosimeter in sheet form was capable of detecting radiation over all tested photon energies and chemical concentrations. The best sensitivity and photostability of the dosimeter were achieved with 2.5% wt. LMG and 8.2% wt. bromoform. Scanner used should not emit any UV radiation as it will expose the dosimeter, as with the Epson 10000 XL scanner. Presage dosimeter in this form was sensitive

  19. PAGAT gel dosimeters for dose distribution measurements in the vicinity of high-density implants: A preliminary study

    NASA Astrophysics Data System (ADS)

    Asena, A.; Kairn, T.; Crowe, S. B.; Smith, S. T.; Trapp, J. V.

    2015-01-01

    This work examined the suitability of the PAGAT gel dosimeter for use in dose distribution measurements around high-density implants. An assessment of the gels reactivity with various metals was performed and no corrosive effects were observed. An artefact reduction technique was also investigated in order to minimise scattering of the laser light in the optical CT scans. The potential for attenuation and backscatter measurements using this gel dosimeter were examined for a temporary tissue expander's internal magnetic port.

  20. In situ ion-beam-induced luminescence analysis for evaluating a micrometer-scale radio-photoluminescence glass dosimeter

    NASA Astrophysics Data System (ADS)

    Kawabata, Shunsuke; Kada, Wataru; Parajuli, Raj Kumar; Matsubara, Yoshinori; Sakai, Makoto; Miura, Kenta; Satoh, Takahiro; Koka, Masashi; Yamada, Naoto; Kamiya, Tomihiro; Hanaizumi, Osamu

    2016-06-01

    Micrometer-scale responses of radio-photoluminescence (RPL) glass dosimeters to focused ionized particle radiation were evaluated by combining ion-beam-induced luminescence (IBIL) and proton beam writing (PBW) using a 3 MeV focused proton microbeam. RPL phosphate glass dosimeters doped with ionic Ag or Cu activators at concentrations of 0.2 and 0.1% were fabricated, and their scintillation intensities were evaluated by IBIL spectroscopy under a PBW micropatterning condition. Compared with the Ag-doped dosimeter, the Cu-doped dosimeter was more tolerant of the radiation, while the peak intensity of its luminescence was lower, under the precise dose control of the proton microprobe. Proton-irradiated areas were successfully recorded using these dosimeters and their RPL centers were visualized under 375 nm ultraviolet light. The reproduction of the irradiated region by post-RPL imaging suggests that precise estimation of irradiation dose using microdosimeters can be accomplished by optimizing RPL glass dosimeters for various proton microprobe applications in organic material analysis and in micrometer-scale material modifications.

  1. Factors Affecting the Application of a Simple Ratio Technique for Spectral Correction of a Neutron Personnel Albedo Dosimeter.

    NASA Astrophysics Data System (ADS)

    Nelson, Robert Clifton

    To accurately assess the dose equivalent indicated by the albedo response of a neutron personnel dosimeter, additional knowledge is generally required in order to apply the needed spectral specific correction factors. This work was designed to evaluate the capability of the USAF Personnel Neutron Dosimeter to "self-calibrate" for moderated fission neutron spectra. The boron/bare ratio technique is compared with a simple theoretical model of the dosimeter and with the 23 cm (9 in) to 7.6 cm (3 in) Hankins' remmeter calibration technique. The overall goal was to provide dose-equivalent estimates comparable to those provided by the remmeter technique without the necessity of special on-site measurements. Although the boron/bare technique with the present dosimeter design fails to provide calibration factors needed for moderated fission neutron spectra, theoretical predictions based upon the model and the measured dosimeter responses are used to propose a dosimeter design which might fulfill the desired goal. Ancillary data gathered during the study are also presented.

  2. Investigation of signal fading in lithium formate EPR dosimeters using a new sensitive method

    NASA Astrophysics Data System (ADS)

    Adolfsson, Emelie; Karlsson, Mattias; Alm Carlsson, Gudrun; Carlsson Tedgren, Åsa; Lund, Eva; Olsson, Sara; Gustafsson, Håkan

    2012-04-01

    The aim of this study was to investigate signal fading in lithium formate electron paramagnetic resonance (EPR) dosimeters used for clinical applications in radiotherapy. A new experimental method for determination of signal fading, designed to resolve small changes in signal from slowly decaying unstable radicals, was used. Possible signal fading in lithium formate due to different storage temperatures was also tested. Air humidity was kept at a constant level of 33% throughout the experiments. The conclusion drawn from the investigations was that the EPR signal from lithium formate is stable during at least 1 month after irradiation and is not sensitive to variations in storage temperature <40 °C when kept at a relative air humidity of 33%. This makes lithium formate a suitable dosimeter for transfer dosimetry in clinical audits.

  3. Response of the alanine/ESR dosimeter to radiation from an Ir-192 HDR brachytherapy source.

    PubMed

    Anton, M; Hackel, T; Zink, K; von Voigts-Rhetz, P; Selbach, H-J

    2015-01-07

    The response of the alanine dosimeter to radiation from an Ir-192 source with respect to the absorbed dose to water, relative to Co-60 radiation, was determined experimentally as well as by Monte Carlo simulations. The experimental and Monte Carlo results for the response agree well within the limits of uncertainty. The relative response decreases with an increasing distance between the measurement volume and the source from approximately 98% at a 1 cm distance to 96% at 5 cm. The present data are more accurate, but agree well with data published by Schaeken et al (2011 Phys. Med. Biol. 56 6625-34). The decrease of the relative response with an increasing distance that had already been observed by these authors is confirmed. In the appendix, the properties of the alanine dosimeter with respect to volume and sensitivity corrections are investigated. The inhomogeneous distribution of the detection probability that was taken into account for the analysis was determined experimentally.

  4. Cyanocobalamin solutions as potential dosimeters in low-dose food irradiations.

    PubMed

    Prakasan, Velayudhan; Sanyal, Bhaskar; Pritamdas Chawla, Surinder; Chander, Ramesh; Sharma, Arun

    2014-04-01

    Potential of aqueous solutions of cyanocobalamin in gamma radiation dosimetry was investigated. The solutions are inexpensive, nontoxic and easy-to-prepare dosimeters, which could be useful for measuring gamma radiation doses in various applications, such as quarantine treatment of fruit or insect disinfestation of grains and pulses. The optical absorbance of cyanocobalamin solutions of the optimal concentration 0.08 mM decreases with increasing radiation dose. The reproducible dependence of the absorbance decrease on the dose can be described with a polynomial. Pre- and post-irradiation stability of the solution absorbance, as well as effects of the irradiation temperature and dose rate, were studied. The response is not significantly affected by storage of the irradiated dosimeters under ambient conditions for 20 days. The performance characteristics of this chemical dosimetry system suggest that it can be useful to measure doses in irradiations of food. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. OSL and TL dosimeter characterization of boron doped CVD diamond films

    NASA Astrophysics Data System (ADS)

    Gonçalves, J. A. N.; Sandonato, G. M.; Meléndrez, R.; Chernov, V.; Pedroza-Montero, M.; De la Rosa, E.; Rodríguez, R. A.; Salas, P.; Barboza-Flores, M.

    2005-04-01

    Natural diamond is an exceptional prospect for clinical radiation dosimetry due to its tissue-equivalence properties and being chemically inert. The use of diamond in radiation dosimetry has been halted by the high market price; although recently the capability of growing high quality CVD diamond has renewed the interest in using diamond films as radiation dosimeters. In the present work we have characterized the dosimetric properties of diamond films synthesized by the HFCVD method. The thermoluminescence and the optically stimulated luminescence of beta exposed diamond sample containing a B/C 4000 ppm doping presents excellent properties suitable for dosimetric applications with β-ray doses up to 3.0 kGy. The observed OSL and TL performance is reasonable appropriate to justify further investigation of diamond films as dosimeters for ionizing radiation, specially in the radiotherapy field where very well localized and in vivo and real time radiation dose applications are essential.

  6. A SiPM based real time dosimeter for radiotherapic beams

    NASA Astrophysics Data System (ADS)

    Berra, A.; Conti, V.; Lietti, D.; Milan, L.; Novati, C.; Ostinelli, A.; Prest, M.; Romanó, C.; Vallazza, E.

    2015-02-01

    This paper describes the development of a scintillator dosimeter prototype for radiotherapic applications based on plastic scintillating fibers readout by Silicon PhotoMultipliers. The dosimeter, whose probes are water equivalent, could be used for quality control measurements, beam characterization and in vivo dosimetry, allowing a real time measurement of the dose spatial distribution. This paper describes the preliminary percentual depth dose scan performed with clinical 6 and 18 MV photon beams, comparing the results with a reference curve. The measurements were performed using a Varian Clinac iX linear accelerator at the Radiotherapy Department of the St. Anna Hospital in Como (IT). The prototype has given promising results, allowing real time measurements of relative dose without applying any correction factors.

  7. Three-dimensional radiation dosimetry for gamma knife using a gel dosimeter

    NASA Astrophysics Data System (ADS)

    Hussain, Kazi Muazzam

    The use of three-dimensional radiation dosimetry has been limited. With the use of water phantoms and ionization chambers, it has been possible to determine three dimensional dose distributions on a gross scale for cobalt 60 and linear accelerator sources. This method has been somewhat useful for traditional radiotherapy. There is, however, a need for more precise dosimetry, particularly with stereotactic radiosurgery. Most gamma knife facilities use either thermoluminescant dosimetry or film, neither of which provides three dimensional dose distributions. To overcome this limitation, we have developed a gel dosimetry system that relies on the production of a ferric ion-xylenol orange colored complex. This work demonstrates the use of laser light and a detector to quantify radiation-induced colorimetric changes in absorbance for the gel dosimeter. The absorbance has been reconstructed by the back projection technique to demonstrate the applicability of the gel dosimeter to gamma knife 3D-dose distributions.

  8. DETECTORS AND EXPERIMENTAL METHODS: Online measurement of the BEPC II background using RadFET dosimeters

    NASA Astrophysics Data System (ADS)

    Gong, Hui; Li, Jin; Gong, Guang-Hua; Li, Yu-Xiong; Hou, Lei; Shao, Bei-Bei

    2009-09-01

    To monitor the integral dose deposited in the BESIII electromagnetic calorimeter whose performance degrades due to exposure to the BEPC II background, a 400 nm IMPL RadFET dosimeter-based integral dose online monitor system is built. After calibration with the 60Co source and verification with TLD in the pulse radiation fields, an experiment was arranged to measure the BEPC II background online. The results are presented.

  9. Thermoluminescent Dosimeter Use for Environmental Surveillance at the Hanford Site, 1971–2005

    SciTech Connect

    Antonio, Ernest J.; Poston, Ted M.; Rathbone, Bruce A.

    2010-03-01

    This report describes the use of thermo luminescent dosimeters for environmental surveillance of external radiation on and around the Hanford Site for the period of 1970 to 2005. It addresses changes in the technology and associated quality control and assurance used in this work and summarizes the results of the 35 year period of external radiation surveillance. The appendices to this report provide trend plots for each location that comprised the shoreline, onsite, perimeter, and offsite sample design.

  10. Development of a Dosimeter System for Unsymmetrical Dimethylhydrazine, Monomethylhydrazine and Hydrazine

    DTIC Science & Technology

    1994-06-27

    ppb-L. The second reaction utilized in the dosimeter system involves 3-methoxy-4- hydroxbenzaldehyde ( vanillin ) for the detection of hydrazine and...MMH (U.S. patent 4,900,681). In the reaction between vanillin and hydrazine or MMH, a yellow hydrazone is formed. When coated on porous filter paper and...and sunlight for the vanillin and 2,4-dinitrobenzaldehyde chemistries, respectively. The incorporation of a polyester sheet impregnated with UV

  11. Does nitrogen gas bubbled through a low density polymer gel dosimeter solution affect the polymerization process?

    PubMed Central

    Shahbazi-Gahrouei, Daryoush; Gholami, Mehrdad; Pourfallah, Tayyeb Allahverdi; Keshtkar, Mohammad

    2015-01-01

    Background: On account of the lower electron density in the lung tissue, the dose distribution in the lung cannot be verified with the existing polymer gel dosimeters. Thus, the aims of this study are to make a low density polymer gel dosimeter and investigate the effect of nitrogen gas bubbles on the R2 responses and its homogeneity. Materials and Methods: Two different types of low density polymer gel dosimeters were prepared according to a composition proposed by De Deene, with some modifications. In the first type, no nitrogen gas was perfused through the gel solution and water. In the second type, to expel the dissolved oxygen, nitrogen gas was perfused through the water and gel solution. The post-irradiation times in the gels were 24 and 5 hours, respectively, with and without perfusion of nitrogen gas through the water and gel solution. Results: In the first type of gel, there was a linear correlation between the doses and R2 responses from 0 to 12 Gy. The fabricated gel had a higher dynamic range than the other low density polymer gel dosimeter; but its background R2 response was higher. In the second type, no difference in R2 response was seen in the dose ranges from 0 to 18 Gy. Both gels had a mass density between 0.35 and 0.45 g.cm-3 and CT values of about -650 to -750 Hounsfield units. Conclusion: It appeared that reactions between gelatin-free radicals and monomers, due to an increase in the gel temperature during rotation in the household mixer, led to a higher R2-background response. In the second type of gel, it seemed that the collapse of the nitrogen bubbles was the main factor that affected the R2-responses. PMID:26015914

  12. Performance characteristics of mobile MOSFET dosimeter for kilovoltage X-rays used in image guided radiotherapy

    PubMed Central

    Kumar, A. Sathish; Singh, I. Rabi Raja; Sharma, S. D.; Ravindran, B. Paul

    2015-01-01

    The main objective of this study was to investigate the characteristics of metal oxide semiconductor field effect transistor (MOSFET) dosimeter for kilovoltage (kV) X-ray beams in order to perform the in vivo dosimetry during image guidance in radiotherapy. The performance characteristics of high sensitivity MOSFET dosimeters were investigated for 80, 90, 100, 110, 120, and 125 kV X-ray beams used for imaging in radiotherapy. This study was performed using Clinac 2100 C/D medical electron linear accelerator with on-board imaging and kV cone beam computed tomography system. The characteristics studied in this work include energy dependence, angular dependence, and linearity. The X-ray beam outputs were measured as per American Association of Physicists in Medicine (AAPM) TG 61 recommendations using PTW parallel plate (PP) ionization chamber, which was calibrated in terms of air kerma (Nk) by the National Standard Laboratory. The MOSFET dosimeters were calibrated against the PP ionization chamber for all the kV X-ray beams and the calibration coefficient was found to be 0.11 cGy/mV with a standard deviation of about ±1%. The response of MOSFET was found to be energy independent for the kV X-ray energies used in this study. The response of the MOSFET dosimeter was also found independent of angle of incidence for the gantry angles in the range of 0° to 360° in-air as well as at 3 cm depth in tissue equivalent phantom. PMID:26500397

  13. TH-C-17A-08: Monte Carlo Based Design of Efficient Scintillating Fiber Dosimeters

    SciTech Connect

    Wiles, A; Loyalka, S; Rangaraj, D; Izaguirre, E

    2014-06-15

    Purpose: To accurately predict Cherenkov radiation generation in scintillating fiber dosimeters. Quantifying Cherenkov radiation provides a method for optimizing fiber dimensions, orientation, optical filters, and photodiode spectral sensitivity to achieve efficient real time imaging dosimeter designs. Methods: We develop in-house Monte Carlo simulation software to model polymer scintillation fibers' fluorescence and Cherenkov emission in megavoltage clinical beams. The model computes emissions using generation probabilities, wavelength sampling, fiber photon capture, and fiber transport efficiency and incorporates the fiber's index of refraction, optical attenuation in the Cherenkov and visible spectrum and fiber dimensions. Detector component selection based on parameters such as silicon photomultiplier efficiency and optical coupling filters separates Cherenkov radiation from the dose-proportional scintillating emissions. The computation uses spectral and geometrical separation of Cherenkov radiation, however other filtering techniques can expand the model. Results: We compute Cherenkov generation per electron and fiber capture and transmission of those photons toward the detector with incident electron beam angle dependence. The model accounts for beam obliquity and nonperpendicular electron fiber impingement, which increases Cherenkov emission and trapping. The rotational angle around square fibers shows trapping efficiency variation from the normally incident minimum to a maximum at 45 degrees rotation. For rotation in the plane formed by the fiber axis and its surface normal, trapping efficiency increases with angle from the normal. The Cherenkov spectrum follows the theoretical curve from 300nm to 800nm, the wavelength range of interest defined by silicon photomultiplier and photodiode spectral efficiency. Conclusion: We are able to compute Cherenkov generation in realistic real time scintillating fiber dosimeter geometries. Design parameters incorporate

  14. Atlas of nuclear emulsion micrographs from personnel dosimeters of manned space missions

    NASA Technical Reports Server (NTRS)

    Schaefer, H. J.; Sullivan, J. J.

    1976-01-01

    A collection of micrographs is presented taken from nuclear emulsions of personnel dosimeter packs carried by the astronauts on near-earth orbital and lunar missions. It is intended as a pictorial record and illustration of the radiation environment in space and as a supplement to earlier reports and publications of the laboratory in which the emulsion findings have been presented in detail for individual missions. A complete list of those earlier accounts precedes the picture sections.

  15. Methylene Chloride Sampling with Passive Dosimeters under Steady-State and Transient Conditions.

    DTIC Science & Technology

    1985-01-01

    Occurences ..e*....... ..... ... 7 2.2 Passive Dosi -eters . * o o . e o o e v o 8 a. General .. ... . . . . . . . o & . * o . * * b. Principles of...methylene chloride absorped on charcoal dosimeters. It involves phase equilibration between a spiked filter paper and the dosi - meter charcoal wafer...The dosi -eter housing is reusable, but the draft shield and charcoal pad -ust be renewed for each exposure. GASBADG’ clai-s the useful range of their

  16. Evaluation of a Thermoluminescent Dosimeter for Personnel Monitoring in the Nuclear-Radiation Environment,

    DTIC Science & Technology

    1983-09-01

    particle surface or near the surface of the polycrystalline dosi - meter’s. This is not observed where the entire particle is irradiated as is the case...could be ,timated, Unfortunately no similar data sets are available from which dosi - meter responses can be calculated for cases where the dosimeter is...spectra at 1.01 kn produced by this source are also given, and are here referred to as the SAI spectra. The dosi - meter data are plotted for STANDING

  17. A response function calculation for a dose-equivalent neutron dosimeter using superheated drops

    SciTech Connect

    Wang, C.K. )

    1991-01-01

    A neutron dosimeter using superheated drops in gel was invented by Apfel. The SDD-100 or BD-100, which uses Freon-12 (CF{sub 2}Cl{sub 2}) for the superheated drops, is most useful in neutron dosimetry because it was claimed that the neutron response function of such a dosimeter is nearly dose equivalent. An ideal dose-equivalent neutron dosimeter should be totally independent of the energies of incident neutrons. Lo and Apfel have performed calculations and experiments to study the neutron response functions for various types of superheated drops, including Freon-12. Both their calculational and the experimental results demonstrated the dose-equivalent-like response function for the Freon-12. The agreement between the calculational results and the experimental results is not satisfactory, however, especially for neutrons with energies < 100 keV. One important factor, which was not considered and may have contributed to the disagreement, is the neutron-slowing-down effect. That is, kilo-electron-volt neutrons, although not energetic enough to trigger bubbles in Freon-12, have a short mean-free-path (< 1 cm) and can easily slow down or thermalize in the gel matrix and then trigger bubbles in Freon-12 via a {sup 35}Cl(n,p){sup 35}S reaction. To consider the slowing-down effect in the dosimeter, a neutron transport calculation must be performed. This paper describes the set of Monte Carlo neutron transport calculations that were performed to calculate the response function for a bare SDD-100 surrounded with various thicknesses of polyethylene (CH{sub 2}).

  18. Clinical application of MOSkin dosimeters to rectal wall in vivo dosimetry in gynecological HDR brachytherapy.

    PubMed

    Carrara, M; Romanyukha, A; Tenconi, C; Mazzeo, D; Cerrotta, A; Borroni, M; Cutajar, D; Petasecca, M; Lerch, M; Bucci, J; Richetti, A; Presilla, S; Fallai, C; Gambarini, G; Pignoli, E; Rosenfeld, A

    2017-09-01

    Three MOSkins dosimeters were assembled over a rectal probe and used to perform in vivo dosimetry during HDR brachytherapy treatments of vaginal cancer. The purpose of this study was to verify the applicability of the developed tool to evaluate discrepancies between planned and measured doses to the rectal wall. MOSkin dosimeters from the Centre for Medical Radiation Physics are particularly suitable for brachytherapy procedures for their ability to be easily incorporated into treatment instrumentation. In this study, 26 treatment sessions of HDR vaginal brachytherapy were monitored using three MOSkin mounted on a rectal probe. A total of 78 measurements were collected and compared to doses determined by the treatment planning system. Mean dose discrepancy was determined as 2.2±6.9%, with 44.6% of the measurements within ±5%, 89.2% within ±10% and 10.8% higher than ±10%. When dose discrepancies were grouped according to the time elapsed between imaging and treatment (i.e., group 1: ≤90min; group 2: >90min), mean discrepancies resulted in 4.7±3.6% and 7.1±5.0% for groups 1 and 2, respectively. Furthermore, the position of the dosimeter on the rectal catheter was found to affect uncertainty, where highest uncertainties were observed for the dosimeter furthest inside the rectum. This study has verified MOSkin applicability to in-patient dose monitoring in gynecological brachytherapy procedures, demonstrating the dosimetric rectal probe setup as an accurate and convenient IVD instrument for rectal wall dose verification. Furthermore, the study demonstrates that the delivered dose discrepancy may be affected by the duration of treatment planning. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  19. Polyvinyl butyral films containing leuco-malachite green as low-dose dosimeters

    NASA Astrophysics Data System (ADS)

    Mai, Hoang Hoa; Solomon, H. M.; Taguchi, M.; Kojima, T.

    2008-04-01

    Thin films containing leuco-malachite green (LMG) dye in polyvinyl butyral (PVB) have been developed for dose measurements of a few hundreds Gy level. The film shows significant color change in the visible range, and the sensitivity of the film to absorbed dose was enhanced by addition of chloride-containing compounds, such as chloral hydrate or 2,2,2-trichloroethanol. The film is suitable as dosimeters for dose measurements, e.g. in food irradiation and environmental protection.

  20. ESR dosimeter material properties of phenols compound exposed to radiotherapeutic electron beams

    NASA Astrophysics Data System (ADS)

    Gallo, Salvatore; Iacoviello, Giuseppina; Bartolotta, Antonio; Dondi, Daniele; Panzeca, Salvatore; Marrale, Maurizio

    2017-09-01

    There is a need for a sensitive dosimeter using Electron Spin Resonance spectroscopy for use in medical applications, since non-destructive read-out and dose archival could be achieved with this method. This work reports a systematic ESR investigation of IRGANOX ® 1076 exposed to clinical electron beams produced by a LINAC used for radiation therapy treatments. Recently, dosimetric features of this material were investigated for irradiation with 60Co γ -photons and neutrons in both pellet and film shape and have been found promising thanks to their high efficiency of radiation-matter energy transfer and radical stability at room temperature. Here the analysis of the dosimetric features of these ESR dosimeters exposed to clinical electron beams at energies of 7, 10 and 14 MeV, is described in terms of dependence on microwave power and modulation amplitude, response on dose, dependence on beam type, detection limits, and signal stability after irradiation. The analysis of the ESR signal as function of absorbed dose highlights that the response of this material is linear in the dose range investigated (1-13 Gy) and is independent of the beam energy. The minimum detectable dose is found to be smaller than 1 Gy. Comparison of electron stopping power values of these dosimeters with those of water and soft tissue highlights equivalence of the response to electron beams in the energy range considered. The signal intensity was monitored for 40 days after irradiation and for all energies considered and it shows negligible variations in the first 500 h after irradiation whereas after 1100 h the signal decay is only of about 4%. In conclusion, it is found that phenolic compounds possess good dosimetric features which make it useful as a sensitive dosimeter for medical applications.

  1. Dose measurement using Al2O3 dosimeter in comparison to LiF:Mg,Ti dosimeter and ionization chamber at low and high energy x-ray

    NASA Astrophysics Data System (ADS)

    Yusof, Mohd Fahmi Mohd; Yahya, Muhammad Hadzmi; Rosnan, Muhammad Syazwan; Abdullah, Reduan; Kadir, Ahmad Bazlie Abdul

    2017-01-01

    The dose measurement using Al2O3 OSL dosimeter (OSLD) was carried out at low and high energy x-ray. The dose at low energy x-ray was measured at 40, 71 and 125 kVp x-ray energies. The dose ar high energy x-ray was measured at 6 and 10 MV x-ray energies measured at the depth of maximum dose (Zmax). The results were compared to that in ionization chamber and LiF: Mg,Ti thermoluminescent dosimeters (TLD100). The results showed that the dose of OSLD were less in agreement to ionization chamber compared to that in TLD100. The dose of OSLD however was in good agreement to that in ionization chamber at high energy x-ray. The dose measured using OSLD were found to be more consistence at high energy x-ray shown by the standard deviation of the readings. The measurement of x2 showed that the readings of OSLD were close to that in ionization chamber with values of 2.21 and 4.63 for 6 and 10 MV respectively. The results indicated that OSLD is more suitable for dose measurement at high energy x-ray.

  2. Glass beads and Ge-doped optical fibres as thermoluminescence dosimeters for small field photon dosimetry.

    PubMed

    Jafari, S M; Alalawi, A I; Hussein, M; Alsaleh, W; Najem, M A; Hugtenburg, R P; Bradley, D A; Spyrou, N M; Clark, C H; Nisbet, A

    2014-11-21

    An investigation has been made of glass beads and optical fibres as novel dosimeters for small-field photon radiation therapy dosimetry. Commercially available glass beads of largest dimension 1.5 mm and GeO2-doped SiO2 optical fibres of 5 mm length and 120 µm diameter were characterized as thermoluminescence dosimeters. Results were compared against Monte-Carlo simulations with BEAMnrc/DOSXYZnrc, EBT3 Gafchromic film, and a high-resolution 2D-array of liquid-filled ionization chambers. Measurements included relative output factors and dose profiles for square-field sizes of 1, 2, 3, 4, and 10 cm. A customized Solid-Water® phantom was employed, and the beads and fibres were placed at defined positions along the longitudinal axis to allow accurate beam profile measurement. Output factors and the beam profile parameters were compared against those calculated by BEAMnrc/DOSXYZnrc. The output factors and field width measurements were found to be in agreement with reference measurements to within better than 3.5% for all field sizes down to 2 cm2 for both dosimetric systems, with the beads showing a discrepancy of no more than 2.8% for all field sizes. The results confirm the potential of the beads and fibres as thermoluminescent dosimeters for use in small photon radiation field sizes.

  3. Determining the mechanical properties of a radiochromic silicone-based 3D dosimeter

    NASA Astrophysics Data System (ADS)

    Kaplan, L. P.; Høye, E. M.; Balling, P.; Muren, L. P.; Petersen, J. B. B.; Poulsen, P. R.; Yates, E. S.; Skyt, P. S.

    2017-07-01

    New treatment modalities in radiotherapy (RT) enable delivery of highly conformal dose distributions in patients. This creates a need for precise dose verification in three dimensions (3D). A radiochromic silicone-based 3D dosimetry system has recently been developed. Such a dosimeter can be used for dose verification in deformed geometries, which requires knowledge of the dosimeter’s mechanical properties. In this study we have characterized the dosimeter’s elastic behaviour under tensile and compressive stress. In addition, the dose response under strain was determined. It was found that the dosimeter behaved as an incompressible hyperelastic material with a non-linear stress/strain curve and with no observable hysteresis or plastic deformation even at high strains. The volume was found to be constant within a 2% margin at deformations up to 60%. Furthermore, it was observed that the dosimeter returned to its original geometry within a 2% margin when irradiated under stress, and that the change in optical density per centimeter was constant regardless of the strain during irradiation. In conclusion, we have shown that this radiochromic silicone-based dosimeter’s mechanical properties make it a viable candidate for dose verification in deformable 3D geometries.

  4. Comparing Handheld Meters and Electronic Dosimeters for Measuring Ultraviolet Levels under Shade and in the Sun.

    PubMed

    Dobbinson, Suzanne; Niven, Philippa; Buller, David; Allen, Martin; Gies, Peter; Warne, Charles

    2016-01-01

    This study aimed to compare the validity, reliability and practicality of alternative portable methods for measuring erythemal UVR levels in passive recreation areas in public parks. UVR levels were measured for point in time comparisons between Solarmeter 6.5 handheld meters and time-stamped electronic dosimeters in a large central park in Melbourne, Australia. Observations were made at 20 locations in the park by two research assistants under two conditions: (1) matched shade (2) contrasting shade-no shade. Comparisons were also made with scientific instruments on the UVR monitoring station rooftop and by remotely selecting UV records and forecasts on cloud-free dates of park observations. There was good agreement between the portable UVR instruments in the park setting as confirmed via Bland Altman plots, while the dosimeter appeared less sensitive to change in shade conditions. The rooftop measurements showed that the Solarmeter 6.5 UVR readings were comparable to those of the adjacent rooftop instruments. The practicalities of using the dosimeters and Solarmeters for behavioral studies are discussed. These findings provide a basis for use of the Solarmeter 6.5 to measure changes in UVR levels due to different environmental conditions with relative accuracy for intervention studies in outdoor settings.

  5. First 3D measurements of proton beams in a deformable silicone-based dosimeter

    NASA Astrophysics Data System (ADS)

    Høye, E. M.; Sadel, M.; Kaplan, L.; Skyt, P. S.; Muren, L. P.; Petersen, J. B. B.; Swakoń, J.; Mierzwińska, G.; Rydygier, M.; Malinowski, L.; Balling, P.

    2017-05-01

    3D dosimetry provides high-resolution dose information of radiation therapy (RT), and is explored to enable and secure high-quality delivery of advanced RT modalities, including proton therapy. We present the first 3D measurements of spot-scanning proton plans in a silicone-based, radiochromic dosimeter with deformation properties. The dose information was read-out by optical CT-scanning. We found that the dosimeter signal was quenched close to the Bragg peak, and that this had a large impact on a measured spread-out Bragg peak. The dose response was linear both in the entrance region and in the Bragg peak, however, the dose response significantly reduced in the Bragg peak. Quenching was attributed to a linear-energy-transfer dependent dose response. Linear energy transfer distributions for each proton treatment plan will provide a means for calibrating the optical measurement to linear energy transfer, as well as dose. This might enable use of the silicone-dosimeter in quality assurance of proton beams.

  6. Real time radiation dosimeters based on vertically aligned multiwall carbon nanotubes and graphene

    NASA Astrophysics Data System (ADS)

    Funaro, Maria; Sarno, Maria; Ciambelli, Paolo; Altavilla, Claudia; Proto, Antonio

    2013-02-01

    Measurements of the absorbed dose and quality assurance programs play an important role in radiotherapy. Ionization chambers (CIs) are considered the most important dosimeters for their high accuracy, practicality and reliability, allowing absolute dose measurements. However, they have a relative large physical size, which limits their spatial resolution, and require a high bias voltage to achieve an acceptable collection of charges, excluding their use for in vivo dosimetry. In this paper, we propose new real time radiation detectors with electrodes based on graphene or vertically aligned multiwall carbon nanotubes (MWCNTs). We have investigated their charge collection efficiency and compared their performance with electrodes made of a conventional material. Moreover, in order to highlight the effect of nanocarbons, reference radiation detectors were also tested. The proposed dosimeters display an excellent linear response to dose and collect more charge than reference ones at a standard bias voltage, permitting the construction of miniaturized CIs. Moreover, an MWCNT based CI gives the best charge collection efficiency and it enables working also to lower bias voltages and zero volts, allowing in vivo applications. Graphene based CIs show better performance with respect to reference dosimeters at a standard bias voltage. However, at decreasing bias voltage the charge collection efficiency becomes worse if compared to a reference detector, likely due to graphene’s semiconducting behavior.

  7. Evaluation of a multi-guard ring (MGR) structure diode as diagnostic X-ray dosimeter

    NASA Astrophysics Data System (ADS)

    Camargo, F.; Khoury, H. J.; Nascimento, C. R.; Asfora, V. K.; Bueno, C. C.

    2007-09-01

    In this paper, we describe the results obtained for the evaluation of a multi-guard ring (MGR) structure diode as diagnostic X-ray dosimeter. This device was developed in the framework of R&D programs for the future CMS experiment at the Large Hadron Collider (LHC) with high radiation hardness to fulfill the requirements from this accelerator environment. In order to use the MGR diode as a dosimeter, it was connected in the photovoltaic mode to the input of an integrating electrometer and positioned at the center of an X-ray beam, beside a previously calibrated ionization chamber. The dependence of the diode response on the X-ray beam doses was evaluated for 35-90 kV X-ray generator bias supply, with doses in the range of 50 μGy-5 mGy. The good linearity of the dose-response curve obtained showed the MGR diode dosimeter to be a reliable alternative method for diagnostic X-ray dosimetry.

  8. A small animal image guided irradiation system study using 3D dosimeters

    NASA Astrophysics Data System (ADS)

    Qian, Xin; Admovics, John; Wuu, Cheng-Shie

    2015-01-01

    In a high resolution image-guided small animal irradiation platform, a cone beam computed tomography (CBCT) is integrated with an irradiation unit for precise targeting. Precise quality assurance is essential for both imaging and irradiation components. The conventional commissioning techniques with films face major challenges due to alignment uncertainty and labour intensive film preparation and scanning. In addition, due to the novel design of this platform the mouse stage rotation for CBCT imaging is perpendicular to the gantry rotation for irradiation. Because these two rotations are associated with different mechanical systems, discrepancy between rotation isocenters exists. In order to deliver x-ray precisely, it is essential to verify coincidence of the imaging and the irradiation isocenters. A 3D PRESAGE dosimeter can provide an excellent tool for checking dosimetry and verifying coincidence of irradiation and imaging coordinates in one system. Dosimetric measurements were performed to obtain beam profiles and percent depth dose (PDD). Isocentricity and coincidence of the mouse stage and gantry rotations were evaluated with starshots acquired using PRESAGE dosimeters. A single PRESAGE dosimeter can provide 3 -D information in both geometric and dosimetric uncertainty, which is crucial for translational studies.

  9. Response of optically stimulated luminescence dosimeters subjected to X-rays in diagnostic energy range

    NASA Astrophysics Data System (ADS)

    Musa, Y.; Hashim, S.; Karim, M. K. A.; Bakar, K. A.; Ang, W. C.; Salehhon, N.

    2017-05-01

    The use of optically stimulated luminescence (OSL) for dosimetry applications has recently increased considerably due to availability of commercial OSL dosimeters (nanoDots) for clinical use. The OSL dosimeter has a great potential to be used in clinical dosimetry because of its prevailing advantages in both handling and application. However, utilising nanoDot OSLDs for dose measurement in diagnostic radiology can only be guaranteed when the performance and characteristics of the dosimeters are apposite. In the present work, we examined the response of commercially available nanoDot OSLD (Al2O3:C) subjected to X-rays in general radiography. The nanoDots response with respect to reproducibility, dose linearity and signal depletion were analysed using microStar reader (Landauer, Inc., Glenwood, IL). Irradiations were performed free-in-air using 70, 80 and 120 kV tube voltages and tube currents ranging from 10 - 100 mAs. The results showed that the nanoDots exhibit good linearity and reproducibility when subjected to diagnostic X-rays, with coefficient of variations (CV) ranging between 2.3% to 3.5% representing a good reproducibility. The results also indicated average of 1% signal reduction per readout. Hence, the nanoDots showed a promising potential for dose measurement in general X-ray procedure.

  10. Feasibility of a semiconductor dosimeter to monitor skin dose in interventional radiology.

    PubMed

    Meyer, P; Regal, R; Jung, M; Siffert, P; Mertz, L; Constantinesco, A

    2001-10-01

    The design and preliminary test results of a semiconductor silicon dosimeter are presented in this article. Use of this dosimeter is foreseen for real-time skin dose control in interventional radiology. The strong energy dependence of this kind of radiation detector is well overcome by filtering the silicon diode. Here, the optimal filter features have been calculated by numerical Monte Carlo simulations. A prototype has been built and tested in a radiological facility. The first experimental results show a good match between the filtered semiconductor diode response and an ionization chamber response, within 2% fluctuation in a 2.2 to 4.1 mm Al half-value layer (HVL) energy range. Moreover, the semiconductor sensor response is linear from 0.02 Gy/min to at least 6.5 Gy/min, covering the whole dose rate range found in interventional radiology. The results show that a semiconductor dosimeter could be used to monitor skin dose during the majority of procedures using x-rays below 150 keV. The use of this device may assist in avoiding radiation-induced skin injuries and lower radiation levels during interventional procedures.

  11. Leuco-crystal-violet micelle gel dosimeters: I. Influence of recipe components and potential sensitizers.

    PubMed

    Nasr, A T; Alexander, K; Schreiner, L J; McAuley, K B

    2015-06-21

    Radiochromic leuco crystal violet (LCV) micelle gel dosimeters are promising three-dimensional radiation dosimeters because of their spatial stability and suitability for optical readout. The effects of surfactant type and surfactant concentration on dose sensitivity of LCV micelle gels are tested, demonstrating that dose sensitivity and initial colour of the gel increases with increasing Triton x-100 (Tx100) concentration. Using Cetyl Trimethyl Ammonium Bromide (CTAB) in place of Tx100 produces gels that are nearly colourless prior to irradiation, but reduces the dose sensitivity. The separate effects of Tri-chloro acetic acid concentration and pH are investigated, revealing that controlling the pH near 3.6 is crucial for achieving high dose sensitivity. The sensitizing effect of chlorinated species on dose sensitivity is tested using 2,2,2-trichloroethanol (TCE), chloroform, and 1,1,1-trichloro-2-methyl-2-propanol hemihydrate. TCE gives the largest improvement in dose sensitivity and is recommended for use in micelle gel dosimeters because it is less volatile and safer to use than chloroform. Preliminary experiments on a new gel containing CTAB as the surfactant and TCE show that this new gel gives a dose sensitivity that is 24% higher than that of previous LCV micelle gels and is nearly colourless prior to irradiation.

  12. Leuco-crystal-violet micelle gel dosimeters: I. Influence of recipe components and potential sensitizers

    NASA Astrophysics Data System (ADS)

    Nasr, A. T.; Alexander, K.; Schreiner, L. J.; McAuley, K. B.

    2015-06-01

    Radiochromic leuco crystal violet (LCV) micelle gel dosimeters are promising three-dimensional radiation dosimeters because of their spatial stability and suitability for optical readout. The effects of surfactant type and surfactant concentration on dose sensitivity of LCV micelle gels are tested, demonstrating that dose sensitivity and initial colour of the gel increases with increasing Triton x-100 (Tx100) concentration. Using Cetyl Trimethyl Ammonium Bromide (CTAB) in place of Tx100 produces gels that are nearly colourless prior to irradiation, but reduces the dose sensitivity. The separate effects of Tri-chloro acetic acid concentration and pH are investigated, revealing that controlling the pH near 3.6 is crucial for achieving high dose sensitivity. The sensitizing effect of chlorinated species on dose sensitivity is tested using 2,2,2-trichloroethanol (TCE), chloroform, and 1,1,1-trichloro-2-methyl-2-propanol hemihydrate. TCE gives the largest improvement in dose sensitivity and is recommended for use in micelle gel dosimeters because it is less volatile and safer to use than chloroform. Preliminary experiments on a new gel containing CTAB as the surfactant and TCE show that this new gel gives a dose sensitivity that is 24% higher than that of previous LCV micelle gels and is nearly colourless prior to irradiation.

  13. Influence of dose history on thermoluminescence response of Ge-doped silica optical fibre dosimeters

    NASA Astrophysics Data System (ADS)

    Moradi, F.; Mahdiraji, G. A.; Dermosesian, E.; Khandaker, M. U.; Ung, N. M.; Mahamd Adikan, F. R.; Amin, Y. M.

    2017-05-01

    Nowadays, silica based optical fibres show enough potential to be used as TL dosimeters in different applications. Reuse of optical fibre as a practical dosimeter demands to complete removal of accumulated doses via previous irradiations. This work investigates the existence and/or effect of remnant doses in fibre dosimeter from the previous irradiations, and proposes a method to control this artifact. A single mode Ge-doped optical fibre is used as TL radiation sensor, while a well calibrated Gammacell with 60Co source is used for irradiations. The effect of irradiation history on the TL response of optical fibres is surveyed extensively for doses ranged from 1 to 1000 Gy. The results show that the absorbed dose history in a fibre affects its response in the next irradiation cycles. It is shown that a dose history of around 100 Gy can increase the response of optical fibre by a factor of 1.72. The effect of annealing at higher temperatures on stabilizing the fibre response is also examined and results revealed that another alteration in the structure of trapping states occurs in glass medium which can change the sensitivity of fibres. Preservation of the sensitivity during successive irradiation cycles can be achieved by a proper annealing procedure accompanied by a pre-dose treatment.

  14. Molecular structure effects on the post irradiation diffusion in polymer gel dosimeters.

    PubMed

    Mattea, Facundo; Romero, Marcelo R; Vedelago, José; Quiroga, Andrés; Valente, Mauro; Strumia, Miriam C

    2015-06-01

    Polymer gel dosimeters have specific advantages for recording 3D radiation dose distribution in diagnostic and therapeutic medical applications. But, even in systems where the 3D structure is usually maintained for long periods of time after irradiation, it is still not possible to eliminate the diffusion of the different species in the regions of dose gradients within the gel. As a consequence, information of the dose loses quality over time. In the pursuit of a solution and to improve the understanding of this phenomenon a novel system based on itaconic acid and N-N'-methylene-bisacrylamide (BIS) is hereby proposed. Effects of changes in the chemical structure of the monomers over the dosimetric sensitivity and over the post-irradiation diffusion of species was studied. In this study, one of the carboxylic groups of the itaconic acid molecule was modified with aniline to obtain molecules with similar reactivity but different molecular sizes. Then, dosimeters based on these modified species and on the original ITA molecules were irradiated in an X-ray tomography apparatus at different doses up to 173Gy. Afterwards, the resulting dosimeters were characterized by Raman spectroscopy and optical absorbance in order to study their feasibility and capabilities as dosimetric systems, and by optical-CT to analyze the post irradiation diffusion. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Radiological properties of nanocomposite Fricke gel dosimeters for heavy ion beams

    PubMed Central

    Maeyama, Takuya; Fukunishi, Nobuhisa; Ishikawa, Kenichi L.; Fukasaku, Kazuaki; Fukuda, Shigekazu

    2016-01-01

    The radiological properties of nanocomposite Fricke gel (NC-FG) dosimeters prepared with different concentrations of nano-clay, perchloric acid and ferrous ions in deaerated conditions were investigated under carbon and argon ion beam irradiation covering a linear-energy-transfer (LET) range of 10 to 3000 eV/nm. We found that NC-FG exhibits radiological properties distinct from those of conventional Fricke gel. The radiation sensitivity of NC-FG is independent of the LET and is nearly constant even at very high LET (3000 eV/nm) values in the Bragg peak region of the argon ion beam. In addition, whereas conventional Fricke gel dosimeters only operate under acidic conditions, NC-FG dosimeters function under both acidic and neutral conditions. The radiation sensitivity decreases with decreasing nano-clay concentration in NC-FG, which indicates that the nano-clay plays a vital role in the radiation-induced oxidation of Fe2+. PMID:26968632

  16. Sensitivity and variability of Presage dosimeter formulations in sheet form with application to SBRT and SRS QA

    SciTech Connect

    Dumas, Michael; Rakowski, Joseph T.

    2015-12-15

    Purpose: To measure sensitivity and stability of the Presage dosimeter in sheet form for various chemical concentrations over a range of clinical photon energies and examine its use for stereotactic body radiation therapy (SBRT) and stereotactic radiosurgery (SRS) QA. Methods: Presage polymer dosimeters were formulated to investigate and optimize their sensitivity and stability. The dosimeter is composed of clear polyurethane base, leucomalachite green (LMG) reporting dye, and bromoform radical initiator in 0.9–1.0 mm thick sheets. The chemicals are mixed together for 2 min, cast in an aluminum mold, and left to cure at 60 psi for a minimum of two days. Dosimeter response was characterized at energies Co-60, 6 MV, 10 MV flattening-filter free, 15 MV, 50 kVp (mean 19.2 keV), and Ir-192. The dosimeters were scanned by a Microtek Scanmaker i800 at 300 dpi, 2{sup 16} bit depth per color channel. Red component images were analyzed with ImageJ and RIT. SBRT QA was done with gamma analysis tolerances of 2% and 2 mm DTA. Results: The sensitivity of the Presage dosimeter increased with increasing concentration of bromoform. Addition of tin catalyst decreased curing time and had negligible effect on sensitivity. LMG concentration should be at least as high as the bromoform, with ideal concentration being 2% wt. Gamma Knife SRS QA measurements of relative output and profile widths were within 2% of manufacturer’s values validated at commissioning, except the 4 mm collimator relative output which was within 3%. The gamma pass rate of Presage with SBRT was 73.7%, compared to 93.1% for EBT2 Gafchromic film. Conclusions: The Presage dosimeter in sheet form was capable of detecting radiation over all tested photon energies and chemical concentrations. The best sensitivity and photostability of the dosimeter were achieved with 2.5% wt. LMG and 8.2% wt. bromoform. Scanner used should not emit any UV radiation as it will expose the dosimeter, as with the Epson 10000 XL scanner

  17. SU-F-BRF-13: Investigating the Feasibility of Accurate Dose Measurement in a Deforming Radiochromic Dosimeter

    SciTech Connect

    Juang, T; Adamovics, J; Oldham, M

    2014-06-15

    Purpose: Presage-Def, a deformable radiochromic 3D dosimeter, has been previously shown to have potential for validating deformable image registration algorithms. This work extends this effort to investigate the feasibility of using Presage-Def to validate dose-accumulation algorithms in deforming structures. Methods: Two cylindrical Presage-Def dosimeters (8cm diameter, 4.5cm length) were irradiated in a water-bath with a simple 4-field box treatment. Isocentric dose was 20Gy. One dosimeter served as control (no deformation) while the other was laterally compressed during irradiation by 21%. Both dosimeters were imaged before and after irradiation with a fast (∼10 minutes for 1mm isotropic resolution), broad beam, high resolution optical-CT scanner. Measured dose distributions were compared to corresponding distributions calculated by a commissioned Eclipse planning system. Accuracy in the control was evaluated with 3D gamma (3%/3mm). The dose distribution calculated for the compressed dosimeter in the irradiation geometry cannot be directly compared via profiles or 3D gamma to the measured distribution, which deforms with release from compression. Thus, accuracy under deformation was determined by comparing integral dose within the high dose region of the deformed dosimeter distribution versus calculated dose. Dose profiles were used to study temporal stability of measured dose distributions. Results: Good dose agreement was demonstrated in the control with a 3D gamma passing rate of 96.6%. For the dosimeter irradiated under compression, the measured integral dose in the high dose region (518.0Gy*cm3) was within 6% of the Eclipse-calculated integral dose (549.4Gy*cm3). Elevated signal was noted on the dosimeter edge in the direction of compression. Change in dosimeter signal over 1.5 hours was ≤2.7%, and the relative dose distribution remained stable over this period of time. Conclusion: Presage-Def is promising as a 3D dosimeter capable of accurately

  18. SU-E-T-171: Characterization of the New Xoft Axxent Electronic Brachytherapy Source Using PRESAGE Dosimeters

    SciTech Connect

    Steinmann, A; Followill, D; Ibbott, G; Adamovics, J

    2015-06-15

    Purpose: To characterize the Xoft Axxent electronic brachytherapy source using PRESAGE™ dosimeters to obtain independent confirmation of TG-43U1 dosimetry values from previous studies and ascertain its reproducibility in HDR brachytherapy. Methods: PRESAGE™ dosimeters are solid, polyurethane-based dosimeters doped with radiochromic leucodyes that produce a linear optical-density response when exposed to radiation. Eight 1-kg dosimeters were scanned prior to irradiation on an optical-CT scanner to eliminate background signal and any optical imperfections from each dosimeter. To quantify potential imaging artifacts due to oversaturated responses in the immediate range of the source, half of the eight dosimeters were cast with a smaller channel diameter of 5.4 mm, and the other half were cast with a larger channel diameter of 15mm. During irradiation, the catheters were placed in the center of each channel. Catheters fit the 5.4mm diameters channels whereas polyurethane plugs were inserted into the larger channels to create a sturdy, immobile catheter which allowed uniform dose distributions. Two dosimeters of each 5.4mm and 15mm were irradiated at either 1517.3 cGy or 2017.5 cGy. Post-irradiation scans were performed within 48 hours of irradiation. A 3D reconstruction based on subtraction of these two images and the relative dose measurements were made using in-house software. Results: Comparing measured radial dose rates with previous results revealed smaller percent errors when PRESAGE™ irradiations were at lower maximum dose. The dosimeters showed small deviations in radial dose function, g{sub p} (r), from previous studies. Among the dosimeters irradiated at 1517.3 cGy, the g{sub p}(r) compared to previous studies fluctuated from 0.0043 to 0.3922. This suggests small fluctuations can drastically change radial dose calculations. Conclusion: The subtraction of pre-irradiation and post-irradiation scans of PRESAGE™ dosimeters using an optical-CT scanner

  19. Red emission phosphor for real-time skin dosimeter for fluoroscopy and interventional radiology

    SciTech Connect

    Nakamura, Masaaki Chida, Koichi; Zuguchi, Masayuki

    2014-10-15

    Purpose: There are no effective real-time direct skin dosimeters for interventional radiology. Such a scintillation dosimeter would be available if there was a suitable red emission phosphor in the medical x-ray range, since the silicon photodiode is a highly efficient device for red light. However, it is unknown whether there is a suitable red emission phosphor. The purpose of this study is to find a suitable red emission phosphor that can be used in x-ray dosimeters. Methods: Five kinds of phosphors which emit red light when irradiated with electron beams or ultraviolet rays in practical devices were chosen. For the brightness measurement, phosphor was put into transparent plastic cells or coated onto plastic sheets. The phosphors were irradiated with medical range x-rays [60–120 kV(peak), maximum dose rate of 160 mGy min{sup −1}], and the emission was measured by a luminance meter. Several characteristics, such as brightness, dose rate dependence, tube voltage dependence, and brightness stability, were investigated. Results: The luminescence of Y V O{sub 4}:Eu, (Y,Gd,Eu) BO{sub 3}, and Y{sub 2}O{sub 3}:Eu significantly deteriorated by 5%–10% when irradiated with continuous 2 Gy x-rays. The 0.5MgF{sub 2}⋅3.5MgO⋅GeO{sub 2}:Mn phosphor did not emit enough. Only the Y{sub 2}O{sub 2}S:Eu,Sm phosphor had hardly any brightness deterioration, and it had a linear relationship so that the x-ray dose rate could be determined from the brightness with sufficient accuracy. For the tube voltage dependence of the Y{sub 2}O{sub 2}S:Eu,Sm phosphor, the brightness per unit dose rate with 120 kV(peak) x-rays was 30% higher than that with 60 kV(peak) x-rays. Conclusions: Five kinds of phosphors were chosen as an x-ray scintillator for a real-time direct skin dosimeter. The Y V O{sub 4}:Eu, (Y,Gd,Eu)BO{sub 3}, and Y{sub 2}O{sub 3}:Eu phosphors had brightness deterioration caused by the x-rays. Only the Y{sub 2}O{sub 2}S:Eu,Sm phosphor had hardly any brightness deterioration

  20. Characterization of ferric ions diffusion in Fricke gel dosimeters by using inverse problem techniques

    NASA Astrophysics Data System (ADS)

    Vedelago, J.; Quiroga, A.; Valente, M.

    2014-10-01

    Diffusion of ferric ions in ferrous sulfate (Fricke) gels represents one of the main drawbacks of some radiation detectors, such as Fricke gel dosimeters. In practice, this disadvantage can be overcome by prompt dosimeter analysis, and constraining strongly the time between irradiation and analysis, implementing special dedicated protocols aimed at minimizing signal blurring due to diffusion effects. This work presents a novel analytic modeling and numerical calculation approach of diffusion coefficients in Fricke gel radiation sensitive materials. Samples are optically analyzed by means of visible light transmission measurements by capturing images with a charge-coupled device camera provided with a monochromatic filter corresponding to the XO-infused Fricke solution absorbance peak. Dose distributions in Fricke gels are suitably delivered by assessing specific initial conditions further studied by periodical sample image acquisitions. Diffusion coefficient calculations were performed using a set of computational algorithms based on inverse problem formulation. Although 1D approaches to the diffusion equation might provide estimations of the diffusion coefficient, it should be calculated in the 2D framework due to the intrinsic bi-dimensional characteristics of Fricke gel layers here considered as radiation dosimeters. Thus a suitable 2D diffusion model capable of determining diffusion coefficients was developed by fitting the obtained algorithm numerical solutions with the corresponding experimental data. Comparisons were performed by introducing an appropriate functional in order to analyze both experimental and numerical values. Solutions to the second-order diffusion equation are calculated in the framework of a dedicated method that incorporates finite element method. Moreover, optimized solutions can be attained by gradient-type minimization algorithms. Knowledge about diffusion coefficient for a Fricke gel radiation detector is helpful in accounting for

  1. Calibration and conformational studies in radiation dosimetry using polymer gel dosimeters

    NASA Astrophysics Data System (ADS)

    Cardenas, Richard L.

    2001-11-01

    The polymer gel dosimeter made its debut in the early 90's and dosimetrists and medical physicists alike were excited about the prospect of using the gel dosimeter as an effective and useful three-dimensional modeling tool. Research in the early to mid-90's brought on better polymer mixtures with greater sensitivity and shelf life. Nearly a decade later, these gels are not being used in a clinical setting. The question is, why are they not being routinely used in the clinical setting for modeling and quality assurance of radiation instrumentation and computer generated treatment plans? There are three main reasons and we address these reasons directly in this investigation. First, every promising experiment performed on these gels were done in ideal conditions. The problem ideal experimentation is that the conditions in a clinical setting are unpredictable hence these idealized protocols could not be easily used in practice. Second, attempts to use the gels in clinical settings had mixed results. There was no real consistency with the results based on calibration curves generated by the gel manufacturer and even based on additional calibration studies performed by the medical physicists. Third, there were no consistent and effective calculation programs that were flexible, rigorous, and consistent to use. Due to these main problems, medical physicists have begun to dismiss the gel dosimeter and reverted to traditional 1-dimensional and 2-dimensional verification methods. What we developed in this study is a means to put the polymer gel dosimeter back into the forefront of dosimetry. First, we performed experiments under a clinical setting. Then, we investigated three different calibration methods, including our very own normalized calibration protocol to identify calibration problems and offer up a solution to this problem. Finally, we also generated a good data processing program that is flexible, rigorous, and consistent to use in any setting. In addition to

  2. Fricke gel dosimeter with improved sensitivity for low-dose-level measurements.

    PubMed

    Vaiente, Mauro; Molina, Wladimir; Silva, Lila Carrizales; Figueroa, Rodolfo; Malano, Francisco; Pérez, Pedro; Santibañez, Mauricio; Vedelago, José

    2016-07-01

    Fricke solution has a wide range of applications as radiation detector and dosimetry. It is particularly appreciated in terms of relevant comparative advantages, like tissue-equivalence when prepared in aqueous media like gel matrix, continuous mapping capability, independence of dose rate and incident direction, as well as linear dose response. This work presents the development and characterization of an improved Fricke gel system, based on modified chemical compositions, making possible its application in clinical radiology due to its improved sensitivity. Properties of standard Fricke gel dosimeter for high-dose levels are used as a starting point, and suitable chemical modifications are introduced and carefully investigated in order to attain high resolution for low-dose ranges, like those corresponding to radiology interventions. The developed Fricke gel radiation dosimeter system achieves the expected typical dose-dependency, showing linear response in the dose range from 20 up to 4000 mGy. Systematic investigations including several chemical compositions are carried out in order to obtain an adequate dosimeter response for low-dose levels. A suitable composition from among those studied is selected as a good candidate for low-dose-level radiation dosimetry consisting of a modified Fricke solution fixed to a gel matrix containing benzoic acid along with sulfuric acid, ferrous sulfate, Xylenol orange, and tridistilled water. Dosimeter samples are prepared in standard vials for in-phantom irradiation and further characterization by spectrophotometry measuring visible light transmission and absorbance before and after irradiation. Samples are irradiated using typical X-ray tubes for radiology and calibrated Farmer-type ionization chamber is used as reference to measure dose rates inside phantoms at vial locations. Once sensitive material composition is optimized, dose-response curves show significant improvement regarding overall sensitivity for low dose levels

  3. Fricke gel dosimeter with improved sensitivity for low-dose-level measurements.

    PubMed

    Valente, Mauro; Molina, Wladimir; Silva, Lila Carrizales; Figueroa, Rodolfo; Malano, Francisco; Pérez, Pedro; Santibañez, Mauricio; Vedelago, José

    2016-07-08

    Fricke solution has a wide range of applications as radiation detector and dosimetry. It is particularly appreciated in terms of relevant comparative advantages, like tissue-equivalence when prepared in aqueous media like gel matrix, continuous mapping capability, independence of dose rate and incident direction, as well as linear dose response. This work presents the development and characterization of an improved Fricke gel system, based on modified chemical compositions, making possible its application in clinical radiology due to its improved sensitivity. Properties of standard Fricke gel dosimeter for high-dose levels are used as a starting point, and suitable chemical modifications are introduced and carefully investigated in order to attain high resolution for low-dose ranges, like those corresponding to radiology interventions. The developed Fricke gel radiation dosimeter system achieves the expected typical dose-dependency, showing linear response in the dose range from 20 up to 4000 mGy. Systematic investigations including several chemical compositions are carried out in order to obtain an adequate dosimeter response for low-dose levels. A suitable composition from among those studied is selected as a good candidate for low-dose-level radiation dosimetry consisting of a modified Fricke solution fixed to a gel matrix containing benzoic acid along with sulfuric acid, ferrous sulfate, Xylenol orange, and tridistilled water. Dosimeter samples are prepared in standard vials for in-phantom irradiation and further characterization by spectrophotometry measuring visible light transmission and absorbance before and after irradiation. Samples are irradiated using typical X-ray tubes for radiology and calibrated Farmer-type ionization chamber is used as reference to measure dose rates inside phantoms at vial locations. Once sensitive material composition is optimized, dose-response curves show significant improvement regarding overall sensitivity for low dose levels

  4. Verification of the pure alanine in PMMA tube dosimeter applicability for dosimetry of radiotherapy photon beams: a feasibility study.

    PubMed

    Al-Karmi, Anan M; Ayaz, Ali Asghar H; Al-Enezi, Mamdouh S; Abdel-Rahman, Wamied; Dwaikat, Nidal

    2015-09-01

    Alanine dosimeters in the form of pure alanine powder in PMMA plastic tubes were investigated for dosimetry in a clinical application. Electron paramagnetic resonance (EPR) spectroscopy was used to measure absorbed radiation doses by detection of signals from radicals generated in irradiated alanine. The measurements were performed for low-dose ranges typical for single-fraction doses often used in external photon beam radiotherapy. First, the dosimeters were irradiated in a solid water phantom to establish calibration curves in the dose range from 0.3 to 3 Gy for 6 and 18 MV X-ray beams from a clinical linear accelerator. Next, the dosimeters were placed at various locations in an anthropomorphic pelvic phantom to measure the dose delivery of a conventional four-field box technique treatment plan to the pelvis. Finally, the doses measured with alanine dosimeters were compared against the doses calculated with a commercial treatment planning system (TPS). The results showed that the alanine dosimeters have a highly sensitive dose response with good linearity and no energy dependence in the dose range and photon beams used in this work. Also, a fairly good agreement was found between the in-phantom dose measurements with alanine dosimeters and the TPS dose calculations. The mean value of the ratios of measured to calculated dose values was found to be near unity. The measured points in the in-field region passed dose-difference acceptance criterion of 3% and those in the penumbral region passed distance-to-agreement acceptance criterion of 3 mm. These findings suggest that the pure alanine powder in PMMA tube dosimeter is a suitable option for dosimetry of radiotherapy photon beams.

  5. Enhancement of Dose Response and Nuclear Magnetic Resonance Image of PAGAT Polymer Gel Dosimeter by Adding Silver Nanoparticles

    PubMed Central

    Sabbaghizadeh, Rahim; Shamsudin, Roslinda; Deyhimihaghighi, Najmeh; Sedghi, Arman

    2017-01-01

    In the present study, the normoxic polyacrylamide gelatin and tetrakis hydroxy methyl phosphoniun chloride (PAGAT) polymer gel dosimeters were synthesized with and without the presence of silver (Ag) nanoparticles. The amount of Ag nanoparticles varied from 1 to 3 ml with concentration 3.14 g/l, thus forming two types of PAGAT polymer gel dosimeters before irradiating them with 6 to 25 Gy produced by 1.25-MeV 60Co gamma rays. In this range, the predominant gamma ray interaction with matter is by Compton scattering effect, as the photoelectric absorption effect diminishes. MRI was employed when evaluating the polymerization of the dosimeters and the gray scale of the MRI film was determined via an optical densitometer. Subsequent analyses of optical densities revealed that the extent of polymerization increased with the increase in the absorbed dose, while the increase of penetration depth within the dosimeters has a reverse effect. Moreover, a significant increase in the optical density-dose response (11.82%) was noted for dosimeters containing 2 ml Ag nanoparticles. PMID:28060829

  6. Enhancement of Dose Response and Nuclear Magnetic Resonance Image of PAGAT Polymer Gel Dosimeter by Adding Silver Nanoparticles.

    PubMed

    Sabbaghizadeh, Rahim; Shamsudin, Roslinda; Deyhimihaghighi, Najmeh; Sedghi, Arman

    2017-01-01

    In the present study, the normoxic polyacrylamide gelatin and tetrakis hydroxy methyl phosphoniun chloride (PAGAT) polymer gel dosimeters were synthesized with and without the presence of silver (Ag) nanoparticles. The amount of Ag nanoparticles varied from 1 to 3 ml with concentration 3.14 g/l, thus forming two types of PAGAT polymer gel dosimeters before irradiating them with 6 to 25 Gy produced by 1.25-MeV 60Co gamma rays. In this range, the predominant gamma ray interaction with matter is by Compton scattering effect, as the photoelectric absorption effect diminishes. MRI was employed when evaluating the polymerization of the dosimeters and the gray scale of the MRI film was determined via an optical densitometer. Subsequent analyses of optical densities revealed that the extent of polymerization increased with the increase in the absorbed dose, while the increase of penetration depth within the dosimeters has a reverse effect. Moreover, a significant increase in the optical density-dose response (11.82%) was noted for dosimeters containing 2 ml Ag nanoparticles.

  7. Durability patch and damage dosimeter: a portable battery-powered data acquisition computer and durability patch design process

    NASA Astrophysics Data System (ADS)

    Haugse, Eric D.; Johnson, Patrick E.; Smith, David L.; Rogers, Lynn C.

    2000-05-01

    Repairs of secondary structure can be accomplished by restoring structural integrity at the damaged area and increasing the structure's damping in the repair region. Increased damping leads to a reduction in resonant response and a repair that will survive for the life of the aircraft. In order to design a repair with effective damping properties, the in-service structural strains and temperatures must be known. A rugged, small and lightweight data acquisition unit called the Damage Dosimeter has been developed to accomplish this task with minimal impact to the aircraft system. Running autonomously off of battery power, the Damage Dosimeter measures three channels of strain at sample rates as high as 15 kilo-samples per second and a single channel of temperature. It merges the functionality of both analog signal conditioning and a digital single board computer on one 3.5 by 5 inch card. The Damage Dosimeter allows an engineer to easily instrument an in-service aircraft to assess the structural response characteristics necessary to properly select damping materials. This information in conjunction with analysis and design procedures can be used to design a repair with optimum effectiveness. This paper will present the motivation behind the development of the Damage Dosimeter along with an overview of its functional capabilities and design. In-service flight data and analysis results will be discussed for two applications. The paper will also describe how the Damage Dosimeter is used to enable the Durability Patch design process.

  8. Radiation-induced refraction artifacts in the optical CT readout of polymer gel dosimeters

    SciTech Connect

    Campbell, Warren G.; Jirasek, Andrew; Wells, Derek M.

    2014-11-01

    Purpose: The objective of this work is to demonstrate imaging artifacts that can occur during the optical computed tomography (CT) scanning of polymer gel dosimeters due to radiation-induced refractive index (RI) changes in polyacrylamide gels. Methods: A 1 L cylindrical polyacrylamide gel dosimeter was irradiated with 3 × 3 cm{sup 2} square beams of 6 MV photons. A prototype fan-beam optical CT scanner was used to image the dosimeter. Investigative optical CT scans were performed to examine two types of rayline bending: (i) bending within the plane of the fan-beam and (ii) bending out the plane of the fan-beam. To address structured errors, an iterative Savitzky–Golay (ISG) filtering routine was designed to filter 2D projections in sinogram space. For comparison, 2D projections were alternatively filtered using an adaptive-mean (AM) filter. Results: In-plane rayline bending was most notably observed in optical CT projections where rays of the fan-beam confronted a sustained dose gradient that was perpendicular to their trajectory but within the fan-beam plane. These errors caused distinct streaking artifacts in image reconstructions due to the refraction of higher intensity rays toward more opaque regions of the dosimeter. Out-of-plane rayline bending was observed in slices of the dosimeter that featured dose gradients perpendicular to the plane of the fan-beam. These errors caused widespread, severe overestimations of dose in image reconstructions due to the higher-than-actual opacity that is perceived by the scanner when light is bent off of the detector array. The ISG filtering routine outperformed AM filtering for both in-plane and out-of-plane rayline errors caused by radiation-induced RI changes. For in-plane rayline errors, streaks in an irradiated region (>7 Gy) were as high as 49% for unfiltered data, 14% for AM, and 6% for ISG. For out-of-plane rayline errors, overestimations of dose in a low-dose region (∼50 cGy) were as high as 13 Gy for

  9. Temporal signal stability of KCl:Eu{sup 2+} storage phosphor dosimeters

    SciTech Connect

    Xiao Zhiyan; Hansel, Rachael; Chen Haijian; Du Dongsu; Yang Deshan; Li, H. Harold

    2013-02-15

    Purpose: Current KCl:Eu{sup 2+} prototype dosimeters require a wait time of 12 h between irradiation and dosimetric readout. Although irradiating the dosimeters in the evening and reading on the following day works well in the clinical schedule, reducing the wait time to few hours is desirable. The purposes of this work are to determine the origin of the unstable charge-storage centers and to determine if these centers respond to optical or thermal excitation prior to dosimetric readout. Methods: Pellet-style KCl:Eu{sup 2+} dosimeters were fabricated in-house for this study. A 6 MV photon beam was used to irradiate the dosimeters. After x ray irradiation, dosimeters were subjected to external excitation with near-infrared (NIR) light, ultraviolet (UV) light, or thermal treatment. Photostimulated luminescence (PSL) signal's temporal stability was subsequently measured at room temperature over a few hours using a laboratory PSL readout system. The dosimeters were also placed in a cryostat to measure the temperature dependence of the temporal stability down to 10 K. Results: Strong F-band was present in the PSL stimulation spectrum, indicating that F-centers were the electron-storage centers in KCl:Eu{sup 2+} where an electron was stored at a chlorine anion vacancy. Due to deep energy-depth (2.2 eV), F-centers were probably not responsible for the fast fading in the first a few hours post x ray irradiation. In addition, weak NIR bands were present. However, there was no change in PSL stabilization rate with intense NIR excitation, suggesting that the NIR bands played no role in the PSL fading. At temperatures lower than 77 K there was almost no signal fading with time. Noticeable PSL was observed for undoped KCl samples at room temperature, suggesting that Cl{sub 2}{sup -} V{sub k} centers served as hole-storage centers for both undoped and doped KCl where a hole was trapped by a chlorine molecular ion. V{sub k} centers were stable at low temperature and became mobile

  10. Personal monitoring of UV radiation

    NASA Astrophysics Data System (ADS)

    Barth, Joachim; Knuschke, Peter

    1994-06-01

    Personal monitoring of till-radiation (UVR) is important fo find out both overexposure and underexposure to UVR. At present polysulfone films seem to be most suitable for these purposes. They allow a reliable measurement of till-exposure to wavelengths between 250 and 330 nm if a number of influencing factors is respected. These are described in detail in a technical report of the Commission Internationale de L'Eclairage (CIE). Own investigations with polysulphone films have shown that these polymers can help as well to detect an overexposure to UVR at workplaces as an UVR-deficiency of people living in an old peoples home. It could be demonstrated that this till-deficiency well correlates to the deficiency of serum 25(OH)D3 levels of these people. Furthermore after optimization of a new phototherapeutic equipment in uniformity of UV-exposure round patients body by polysulphone film dosimeters it got useable in therapy.

  11. Vertical distribution of outdoor radon and thoron in Japan using a new discriminative dosimeter

    SciTech Connect

    Doi, Masahiro; Kobayashi, Sadayoshi

    1994-10-01

    Passive measurements of outdoor radon and thoron concentrations were conducted from June 1992 to June 1993 at a monitoring station over a soil area (10 m x 6 m) in Chiba city, Japan. The measurement period was divided into 4 parts to investigate seasonal variations of radon and thoron concentrations. Ten passive radon-thoron discriminative dosimeters (R-T dosimeters) were placed in duplicate at 5 different altitudes to show the vertical distributions of outdoor radon and thoron concentrations. Outdoor radon concentrations showed no significant difference within 1.0 m above the ground, and the annual average of outdoor radon concentration was 3.85 {+-} 0.19 (SE) Bq m{sup {minus}3}. Annual averages of outdoor thoron concentrations at 0.04, 0.15, 0.25, 0.70, and 1.0 m above the ground were 40.5 {+-} 4.4, 22.5 {+-} 3.7, 13.9 {+-} 3.1, 9.5 {+-} 2.9 (SE) Bq m{sup {minus}3}, and < 9.0 Bq m{sup {minus}3}; the lower detection limit of the dosimeter, respectively, and their vertical profiles, n(z) (Bq m{sup {minus}3}), were expressed well by the formula n(z) = {alpha}z{sup B}. Vertical profiles of the atmospheric turbulent diffusion coefficient were also estimated from the observed thoron profiles, as expressed by the power function K(z) = A z{sup B}, of which B values were estimated to vary from 1.034 to 1.609 if averaged thoron exhalation rates during the measurement period were within 0.3 to 2.8 (Bq m{sup {minus}2} s{sup {minus}1}). 45 refs., 6 figs., 3 tabs.

  12. Vertical distribution of outdoor radon and thoron in Japan using a new discriminative dosimeter.

    PubMed

    Doi, M; Kobayashi, S

    1994-10-01

    Passive measurements of outdoor radon and thoron concentrations were conducted from June 1992 to June 1993 at a monitoring station over a soil area (10 m x 6 m) in Chiba city, Japan. The measurement period was divided into 4 parts to investigate seasonal variations of radon and thoron concentrations. Ten passive radon-thoron discriminative dosimeters (R-T dosimeters) were placed in duplicate at 5 different altitudes to show the vertical distributions of outdoor radon and thoron concentrations. Outdoor radon concentrations showed no significant difference within 1.0 m above the ground, and the annual average of outdoor radon concentration was 3.85 +/- 0.19 (SE) Bq m-3. Annual averages of outdoor thoron concentrations at 0.04, 0.15, 0.25, 0.70, and 1.0 m above the ground were 40.5 +/- 4.4, 22.5 +/- 3.7, 13.9 +/- 3.1, 9.5 +/- 2.9 (SE) Bq m-3, and < 9.0 Bq m-3; the lower detection limit of the dosimeter, respectively, and their vertical profiles, n(z) (Bq m-3), were expressed well by the formula n(z) = alpha z beta. Vertical profiles of the atmospheric turbulent diffusion coefficient were also estimated from the observed thoron profiles, as expressed by the power function K(z) = AzB, of which B values were estimated to vary from 1.034 to 1.609 if averaged thoron exhalation rates during the measurement periods were within 0.3 to 2.8 (Bq m-2 s-1).

  13. SU-E-T-511: Do Presage 3D Dosimeters Show Dose Fractionation Sensitivity?

    SciTech Connect

    Klawikowski, S; Alqathami, M; Ibbott, G; Adamovics, J; Benning, R

    2014-06-01

    Purpose: To determine whether Presage 3D polymer dosimeter dose response is sensitive to dose delivery fractionation. Bang gels have demonstrated a dose fractionation related dependence in which a single 400 cGy irradiation would produce a different detector response than four 100 cGy irradiations even if delivered closely in time to one another. Such a fractional dependent response in Presage would be detrimental for measuring multi-beam irradiations. Methods: Two separate batches of Presage were poured into cuvettes, and a third batch was molded into cuvette shaped blocks. A total of 37 cuvettes/blocks were irradiated in a Cobalt-60 irradiator to 400 cGy within solid water phantoms in either one, eight, or sixteen fractions. Another group of 15 cuvettes were also kept unirradiated and used for background subtraction between the pre-scan and post-scan results. The times between fractional deliveries were held constant at 30 seconds and the Cobalt irradiator dose rate was 49 cGy/min. Each Presage batch has a separate dose sensitivity and therefore fractionation response comparisons were only performed within the same batch. The cuvettes were first pre-scanned the day prior to irradiation and post-scanned the day after irradiation. Other than approximately 3 hours warming time prior to each irradiation and optical density measurement the cuvettes were stored in a refrigerator. All cuvettes were stored in a lightless environment throughout manufacturing and testing. The cuvettes’ optical densities were optically measured at 632 nm with a spectrophotometer. Results: No noticeable dose fractionation dependence was detected for any of the three independent batches of Presage for either the eight or sixteen fraction irradiation schemes. Conclusion: These results indicate using Presage 3D dosimeters to measure multi-beam photon irradiations common in IMRT, Gamma Knife, and Cyberknife treatment delivery schemes. Presage dosimeters are made by and trademarked by Heuris

  14. Relative response of the alanine dosimeter to medium energy x-rays.

    PubMed

    Anton, M; Büermann, L

    2015-08-07

    The response of the alanine dosimeter to kilovoltage x-rays with respect to the dose to water was measured, relative to the response to Co-60 radiation.Two series of x-ray qualities were investigated, one ranging from 30 kV to 100 kV tube voltage (TW series), the other one ranging from 70 kV to 280 kV (TH series). Due to the use of the water calorimeter as a primary standard, the uncertainty of the delivered dose is significantly lower than for other published data. The alanine response was measured as described in a previous publication (Anton et al 2013 Phys. Med. Biol. 58 3259-82). The uncertainty component due to the alanine measurement and analysis is ⩽0.4%, the major part of the combined uncertainty of the relative response originates from the uncertainty of the delivered dose. The relative uncertainties of the relative response vary from ⩽2% for the TW series to ⩽1.1% for the TH series.Different from the behaviour of the alanine dosimeter for megavoltage x-rays or electrons, the relative response drops significantly from unity for Co-60 radiation to less than 64% for the TW quality with a tube voltage of 30 kV. In order to reproduce this behaviour through Monte Carlo simulations, not only the ratio of the absorbed dose to alanine to the absorbed dose to water has to be known, but also the intrinsic efficiency, i.e. the dependence of the number of free radicals generated per unit of absorbed dose on the photon energy. This quantity is not yet accessible for the TW series.For a possible use of the alanine dosimeter for kilovoltage x-rays, for example in electronic brachytherapy, users should rely on the measured data for the relative response which have become available with this publication.

  15. Study on the feasibility of the HgI2 dosimeter for quality assurance of radiotherapy

    NASA Astrophysics Data System (ADS)

    Kim, S.-W.; Shin, J.-W.; Oh, K.-M.; Noh, S.-J.; Lee, Y.-K.; Cho, H.-L.; Ahn, K.-J.; Kim, C.-J.; Kim, J.-Y.; Suh, T.-S.; Nam, S.-H.; Park, S.-K.

    2013-05-01

    In radiotherapy, a variety of detectors such as ionization chambers, films, TLDs, diodes, and OSL, are being used for quality assurance (QA). Owing to its high sensitivity and feasibility to operate at low voltages, silicon (Si) photoconductors, which are used as detection material of a diode, are currently being used as relative dosimeters. In addition, other materials such as amorphous selenium (a-Se), cadmium telluride (CdTe), lead iodide (PbI2), and mercury iodide (HgI2) were also being investigated for their feasibility as diagnostic radiation detector. Among these materials, HgI2 has been reported to show remarkable properties including high spatial resolution and high stopping power. Hence In this study, we have verified the feasibility of HgI2 dosimeter for quality assurance of radiotherapy. In order to fabricate the detector, HgI2 was mixed with TiO2 to minimize the signal reduction. Following this, the resulting mixture was deposited onto indium tin oxide (ITO) coated glass by particle-in binder (PIB) method. Finally, the top ITO electrode was coated by magnetron sputterring system. Subsequently, we measured the electrical properties generated by high-energy radiation from linear accelerator (LINAC), and analyzed the reproducibility, linearity, and percent depth dose (PDD) of the fabricated detoctor. In addition, we have determined the build-up materials in experimental setup, since the thickness of build-up region, where the secondary electron emission equilibrium occurs, changes depending on radiation energy. It was observed that the relative variations measured as standard deviation divided by the average value among repeated measurements was approximately 1%. Deviations from linearity are smaller than 5%. Finally, we compared the experimental data of the detector fabricated in this study with those of the farmer-type ionization chamber. Base on the results obtained from this study, it could be realized that HgI2 could be used as dosimeter for QA of

  16. CFRMF spectrum update and application to dosimeter cross-section data testing

    SciTech Connect

    Anderl, R.A.; Harker, Y.D.; Millsap, D.A.; Rogers, J.W.; Ryskamp, J.M.

    1982-01-01

    The Coupled Fast Reactivity Measurements Facility (CFRMF) at the Idaho National Engineering Laboratory (INEL) is a Cross Section Evaluation Working Group (CSEWG) benchmark for data testing of dosimetry, fission-product and actinide cross sections important to fast-reactor technology. In this paper we present the results of our work in updating the CFRMF spectrum characterization and in applying CFRMF integral data to testing ENDF/B-V dosimeter cross sections. Updated characterization of the central neutron spectrum includes the results of neutronics calculations with ENDF/B-V nuclear data, the generation of a fine-group spectrum representation for integral data-testing applications, and a sensitivity and uncertainty analysis which provides a flux-spectrum covariance matrix related to uncertainties and correlations in the nuclear data used in a neutronics calculation. Our application of CFRMF integral data to cross section testing has included both conventional integral testing analyses and least-squares-adjustment analyses with the FERRET code. The conventional integral data-testing analysis, based on C/E ratios, indicates discrepancies outside the estimated integral test uncertainty for the /sup 6/Li(n,He), /sup 10/B(n,He), /sup 47/Ti(n,p), /sup 58/Fe(n,..gamma..), /sup 197/Au(n,..gamma..) and /sup 232/Th(n,..gamma..) cross sections. The integral test uncertainty included contributions from the measured integral data and from the spectrum and cross sections used to obtain the calculated integral data. Within the uncertainty and correlation specifications for the input spectrum and dosimeter cross sections, the least-squares-adjustment analysis indicated a high degree of consistency between the measured integral data and the ENDF/B-V dosimeter cross sections for all reactions except /sup 10/B(n,He).

  17. Effect of dosimeter's position on occupational radiation extremity dose measurement for nuclear medicine workers during (18)F-FDG preparation for PET/CT.

    PubMed

    Salesses, Fabien; Perez, Paul; Maillard, Aline E; Blanchard, Julie; Mallard, Sabine; Bordenave, Laurence

    2016-12-01

    The recent spread of positron emission tomography-computed tomography (PET/CT) poses extremity dosimetry challenges. The question arose whether the radiation dose measured by the ring thermoluminescent dosimeter usually worn on the proximal phalanx (P1) of the index finger measures doses that are representative of the true doses received by the upper extremities of the operators. A prospective individual dosimetry study was performed in which the personal equivalent dose Hp (0.07) received during a specific 2-[(18)F]fluoro-2-deoxy-D-glucose ((18)F-FDG) manual dose-dispensing procedure was measured in a paired design by two operational personal electronic dosimeters fitted on the palm side of the index finger, namely in the P1 and distal phalanx (P3) positions. The study participants were ten nuclear medicine technologists working in two nuclear medicine departments. The personal equivalent radiation doses received by the palm side of the proximal phalanx of the index finger [Hp (0.07)P1] and that received by the distal phalanx [Hp (0.07)P3] were compared. The median Hp (0.07)P3/Hp (0.07)P1 ratio per participant varied between 1.0 and 2.5 (based on 23 to 31 measurements per participant). The 271 paired measurements revealed a crude Hp (0.07)P3/Hp (0.07)P1 ratio of 1.67, significantly different from 1 (p = 0.0004, 95 % CI [1.35-2.07]). When adjusted on participant's gender and mother vial activity, the ratio was similar (1.53, p = 0.003, 95 % CI [1.22-1.92]). The study demonstrated a significant disparity that may exist between the radiation doses measured in the P1 and P3 positions of operators during (18)F-FDG manipulation. These findings emphasize the importance of performing workplace dosimetry studies adapted to each radiopharmaceutical and manipulation thereof, aiming to guarantee optimal workers' dosimetry monitoring schemes. Hospital Nursing and Paramedical Research Program (PHRIP, 2011-2013) from the French Ministry of Health (DGOS), http

  18. Thermoluminescent characteristics of new pre-calibrated dosimeters (TLD) in commercially available readers for selected applications

    NASA Astrophysics Data System (ADS)

    Tawil, R. A.; Pontikos, P.; Szalanczy, A.; Velbeck, K.; Bruml, W.; Rotunda, J. E.

    1994-12-01

    This paper reports the performance of newly developed pre-calibrated Thermoluminescent Dosimeters (TLD) with a description and performance results for two commercially available TLD readers. Introduced for use in basic research, medical diagnostics and therapy applications, the Harshaw Model 5500 Automatic TLD Reader evaluates up to 50 dosimeters (rods, chips, disks, μ-cubes) per loading; the Harshaw Model 3500 Manual TLD Reader evaluates single dosimeters and powder. Tests were conducted using the International Electrotechnical Commission (IEC) guidelines for TLD readers to determine system performance and compliance. Both instruments passed the compliance standards in all tests established by the IEC: detection thresholds for both instruments were less than 10μGy, reproducibility was better than 0.7%, sensitivity to ambient light was less than 0.2 Hmax (where Hmax is the maximum detection threshold), TL residue was less than 1% of the total integral charge, stability less than 1% deviation after a 24 hour warm-up period, linearity was within specification, test light stability was under 1%, and power leakage requirements set forth by UL-544 (less than 500 μA AC RMS leakage) was less than 42 μA AC RMS in all cases. The characteristics of newly introduced, factory calibrated, extruded TLD-100 rods were investigated by studying the consistency of the Element Correction Coefficients (ECCs) under a variety of conditions. The ECC (< x> / xi) relates an individual dosimeter's response, xi, to the mean response, < x>, of the group. Supralinearity effects and the validity of ECCs generated at 1 cGy for use in the 50-900 cGy dose range were characterized and reported. The results for two specific applications, phantom studies with 60Co and at four Orthovoltage energies are also reported. Portability of Element Correction Coefficients from reader to reader was achieved with a relative standard deviation of less than 1.7%. The relative standard deviation of five TLDs

  19. Dosimeter design, construction, and implantation. [for recording HZE cosmic particle tracks

    NASA Technical Reports Server (NTRS)

    Winter, D. L.; Suri, K.; Durso, J. A.; Cota, F. L.; Ashley, W. W.; Binnard, R. M.; Haymaker, W.; Benton, E. V.; Cruty, M. R.; Zeman, W.

    1975-01-01

    To detect the passage of cosmic ray particles through the heads of the pocket mice during the Apollo XVII flight, a 'monitor' (dosimeter) composed of plastics was prepared and implanted under the scalp. The monitor was mounted on a platform, the undersurface of which fitted the contour of the skull. Numerous tests were run to assure that the presence of the monitor assembly beneath the scalp would be compatible with the well-being of the mice and that the capacity of the monitor to detect the traversal of cosmic ray particles would be preserved over the several weeks during which it would remain under the scalp.

  20. Radiation chemistry of heavy-particle tracks. II. Fricke dosimeter system

    SciTech Connect

    Chatterjee, A.; Magee, J.L.

    1980-12-25

    A heavy-particle-track model suggested by considerations presented in a companion paper is used in a calculation of the differential (G') and integral (G) yields of the Fricke dosimeter system for six selected particles over a wide range of energies. The particles are H, He, C, Ne, Ar, and Fm; the energy range for the first two is 10/sup -3/-10/sup 3/ MeV/n, and for the last four is 10/sup -1/-10/sup 3/ MeV/n. The calculated G' and G values are compared with experimental values as far as possible, and the heavy-particle-track model situation is discussed.

  1. SU-E-T-476: Improving KCl:Eu2+ Dosimeter Sensitivity: The Role of Oxygen

    SciTech Connect

    Xiao, Z; Mazur, T; Li, H; Driewer, J

    2015-06-15

    Purpose: Recent research has shown that KCl:Eu2+ has great potential for use in megavoltage radiation therapy dosimetry because this material exhibits excellent storage performance and is reusable due to strong radiation hardness. The purpose of this work is to determine if increased signal could be realized in KCl:Eu2+ by incorporating oxygen in the material fabrication process. Methods: The prototype KCl:Eu2+ dosimeters have a physical makeup similar to thermoluminescent dosimeter chips. The photostimulation light source consists of either a He-Ne laser or a UV enhanced Xe arc lamp with wavelength selection provided by a motorized monochromator. X-ray diffraction is used to determine the phase composition of the dosimeters. Photoluminescence (PL) and photostimulated luminescence (PSL) emission spectra are obtained using a Nanolog Spectrofluoremeter. Results: Europium activator is completely incorporated into the KCl parent-matrix without the formation of a noticeable secondary phase. Regardless of synthesis atmosphere, air or pure nitrogen, PSL amplitude shows a maximum at 1.0 mol % Eu. Depending on europium concentration, dosimeters fabricated in air exhibit stronger PSL by a factor of 2 to 4 compared to those made in N2. There is no change in PSL stimulation spectrum while noticeable shifts in both PL and PSL emission spectra are observed for air versus nitrogen. Almost all charge-storage centers are spatially correlated, suggesting oxygen’s stabilization role in the PSL process. KCl:Eu2+ made in oxygen-rich air is capable of measuring a dose-to-water as low as 0.01 cGy from a 6MV photon beam with a signal-to-noise ratio greater than 6. Conclusions: Synthesis in a reduction atmosphere, for example, nitrogen, was thought to be mandatory in order to retain europium activator’s divalent status to be PSL active. Fortunately, divalent europium can be well preserved in an oxygen-rich atmosphere. More importantly, oxygen can enhance PSL by a factor of 2 to 4. HL

  2. Measurement of bow tie profiles in CT scanners using a real-time dosimeter

    SciTech Connect

    Whiting, Bruce R.; Evans, Joshua D.; Williamson, Jeffrey F.; Dohatcu, Andreea C.; Politte, David G.

    2014-10-15

    Purpose: Several areas of computed tomography (CT) research require knowledge about the intensity profile of the x-ray fan beam that is introduced by a bow tie filter. This information is considered proprietary by CT manufacturers, so noninvasive measurement methods are required. One method using real-time dosimeters has been proposed in the literature. A commercially available dosimeter was used to apply that method, and analysis techniques were developed to extract fan beam profiles from measurements. Methods: A real-time ion chamber was placed near the periphery of an empty CT gantry and the dose rate versus time waveform was recorded as the x-ray source rotated about the isocenter. In contrast to previously proposed analysis methods that assumed a pointlike detector, the finite-size ion chamber received varying amounts of coverage by the collimated x-ray beam during rotation, precluding a simple relationship between the source intensity as a function of fan beam angle and measured intensity. A two-parameter model for measurement intensity was developed that included both effective collimation width and source-to-detector distance, which then was iteratively solved to minimize the error between duplicate measurements at corresponding fan beam angles, allowing determination of the fan beam profile from measured dose-rate waveforms. Measurements were performed on five different scanner systems while varying parameters such as collimation, kVp, and bow tie filters. On one system, direct measurements of the bow tie profile were collected for comparison with the real-time dosimeter technique. Results: The data analysis method for a finite-size detector was found to produce a fan beam profile estimate with a relative error between duplicate measurement intensities of <5%. It was robust over a wide range of collimation widths (e.g., 1–40 mm), producing fan beam profiles that agreed with a relative error of 1%–5%. Comparison with a direct measurement technique on

  3. Response of lithium formate EPR dosimeters at photon energies relevant to the dosimetry of brachytherapy

    SciTech Connect

    Adolfsson, Emelie; Alm Carlsson, Gudrun; Grindborg, Jan-Erik; Gustafsson, Haakan; Lund, Eva; Carlsson Tedgren, Aasa

    2010-09-15

    Purpose: To investigate experimentally the energy dependence of the detector response of lithium formate EPR dosimeters for photon energies below 1 MeV relative to that at {sup 60}Co energies. High energy photon beams are used in calibrating dosimeters for use in brachytherapy since the absorbed dose to water can be determined with high accuracy in such beams using calibrated ion chambers and standard dosimetry protocols. In addition to any differences in mass-energy absorption properties between water and detector, variations in radiation yield (detector response) with radiation quality, caused by differences in the density of ionization in the energy imparted (LET), may exist. Knowledge of an eventual deviation in detector response with photon energy is important for attaining high accuracy in measured brachytherapy dose distributions. Methods: Lithium formate EPR dosimeters were irradiated to known levels of air kerma in 25-250 kV x-ray beams and in {sup 137}Cs and {sup 60}Co beams at the Swedish Secondary Standards Dosimetry Laboratory. Conversions from air kerma free in air into values of mean absorbed dose to the detectors were made using EGSnrc MC simulations and x-ray energy spectra measured or calculated for the actual beams. The signals from the detectors were measured using EPR spectrometry. Detector response (the EPR signal per mean absorbed dose to the detector) relative to that for {sup 60}Co was determined for each beam quality. Results: Significant decreases in the relative response ranging from 5% to 6% were seen for x-ray beams at tube voltages {<=}180 kV. No significant reduction in the relative response was seen for {sup 137}Cs and 250 kV x rays. Conclusions: When calibrated in {sup 60}Co or MV photon beams, corrections for the photon energy dependence of detector response are needed to achieve the highest accuracy when using lithium formate EPR dosimeters for measuring absorbed doses around brachytherapy sources emitting photons in the energy

  4. Study of Fricke-gel dosimeter calibration for attaining precise measurements of the absorbed dose

    SciTech Connect

    Liosi, Giulia Maria; Benedini, Sara; Giacobbo, Francesca; Mariani, Mario; Gambarini, Grazia; Artuso, Emanuele; Gargano, Marco; Ludwig, Nicola; Carrara, Mauro; Pignoli, Emanuele

    2015-07-01

    A method has been studied for attaining, with good precision, absolute measurements of the spatial distribution of the absorbed dose by means of the Fricke gelatin Xylenol Orange dosimetric system. With this aim, the dose response to subsequent irradiations was analyzed. In fact, the proposed modality is based on a pre-irradiation of each single dosimeter in a uniform field with a known dose, in order to extrapolate a calibration image for a subsequent non-uniform irradiation with an un-known dose to be measured. (authors)

  5. A method to correct for stray light in telecentric optical-CT imaging of radiochromic dosimeters

    PubMed Central

    Thomas, Andrew; Newton, Joseph

    2011-01-01

    Radiochromic plastic and gel materials have recently emerged which can yield 3D dose information over clinical volumes in high resolution. These dosimeters can provide a much more comprehensive verification of complex radiation therapy treatments than can be achieved by conventional planar and point dosimeters. To achieve full clinical potential, these dosimeters require a fast and accurate read-out technology. Broad-beam optical-computed tomography (optical-CT) systems have shown promise, but can be sensitive to stray light artifacts originating in the imaging chain. In this work we present and evaluate a method to correct for stray light artifacts by deconvolving a measured, spatially invariant, point spread function (PSF). The correction was developed for the DLOS (Duke large field-of-view optical-CT scanner) in conjunction with radiochromic PRESAGE® dosimeters. The PSF was constructed from a series of acquisitions of projection images of various sized apertures placed in the optical imaging chain. Images were acquired with a range of exposure times, and for a range of aperture sizes (0.2–11 mm). The PSF is investigated under a variety of conditions, and found to be robust and spatially invariant, key factors enabling the viability of the deconvolution approach. The spatial invariance and robustness of the PSF are facilitated by telecentric imaging, which produces a collimated light beam and removes stray light originating upstream of the imaging lens. The telecentric capability of the DLOS therefore represents a significant advantage, both in keeping stray light levels to a minimum and enabling viability of an accurate PSF deconvolution method to correct for the residual. The performance of the correction method was evaluated on projection images containing known optical-density variations, and also on known 3D dose distributions. The method is shown to accurately account for stray light on small field dosimetry with corrections up to 3% in magnitude shown

  6. Dosimetry auditing procedure with alanine dosimeters for light ion beam therapy.

    PubMed

    Ableitinger, Alexander; Vatnitsky, Stanislav; Herrmann, Rochus; Bassler, Niels; Palmans, Hugo; Sharpe, Peter; Ecker, Swantje; Chaudhri, Naved; Jäkel, Oliver; Georg, Dietmar

    2013-07-01

    In the next few years the number of facilities providing ion beam therapy with scanning beams will increase. An auditing process based on an end-to-end test (including CT imaging, planning and dose delivery) could help new ion therapy centres to validate their entire logistic chain of radiation delivery. An end-to-end procedure was designed and tested in both scanned proton and carbon ion beams, which may also serve as a dosimetric credentialing procedure for clinical trials in the future. The developed procedure is focused only on physical dose delivery and the validation of the biological dose is out of scope of the current work. The audit procedure was based on a homogeneous phantom that mimics the dimension of a head (20 × 20 × 21 cm(3)). The phantom can be loaded either with an ionisation chamber or 20 alanine dosimeters plus 2 radiochromic EBT films. Dose verification aimed at measuring a dose of 10Gy homogeneously delivered to a virtual-target volume of 8 × 8 × 12 cm(3). In order to interpret the readout of the irradiated alanine dosimeters additional Monte Carlo simulations were performed to calculate the energy dependent detector response of the particle fluence in the alanine detector. A pilot run was performed with protons and carbon ions at the Heidelberg Ion Therapy facility (HIT). The mean difference of the absolute physical dose measured with the alanine dosimeters compared with the expected dose from the treatment planning system was -2.4 ± 0.9% (1σ) for protons and -2.2 ± 1.1% (1σ) for carbon ions. The measurements performed with the ionisation chamber indicate this slight underdosage with a dose difference of -1.7% for protons and -1.0% for carbon ions. The profiles measured by radiochromic films showed an acceptable homogeneity of about 3%. Alanine dosimeters are suitable detectors for dosimetry audits in ion beam therapy and the presented end-to-end test is feasible. If further studies show similar results, this dosimetric audit could be

  7. Cosmic Radiation Intensity Measurements Using TL Dosimeters at Various Mountain Altitudes

    NASA Astrophysics Data System (ADS)

    Sdrolia, Athina; Sfamba, Ioanna; Liolios, Anastasios; Kitis, Georgios

    2010-01-01

    The Earth is bombarded by cosmic radiation, a nearly isotropic flux of energetic charged particles. Their interaction with air nuclei generates a cascade of secondary particles and gamma rays. This work describes the results of measurements of cosmic radiation at various altitudes on mount Olympus using TL dosimeters (Al2O3:C). The glow curves of TLDs after external exposure have been compared to the ones obtained after beta irradiation in the laboratory. Pb-shielding was used for separation of gamma contribution from terrestrial radiation environment.

  8. Experimental determination of the PTW 60019 microDiamond dosimeter active area and volume.

    PubMed

    Marinelli, Marco; Prestopino, G; Verona, C; Verona-Rinati, G

    2016-09-01

    Small field output correction factors have been studied by several research groups for the PTW 60019 microDiamond (MD) dosimeter, by comparing the response of such a device with both reference dosimeters and Monte Carlo simulations. A general good agreement is observed for field sizes down to about 1 cm. However, evident inconsistencies can be noticed when comparing some experimental results and Monte Carlo simulations obtained for smaller irradiation fields. This issue was tentatively attributed by some authors to unintentional large variations of the MD active surface area. The aim of the present study is a nondestructive experimental determination of the MD active surface area and active volume. Ten MD dosimeters, one MD prototype, and three synthetic diamond samples were investigated in the present work. 2D maps of the MD response were recorded under scanned soft x-ray microbeam irradiation, leading to an experimental determination of the device active surface area. Profiles of the device responses were measured as well. In order to evaluate the MD active volume, the thickness of the diamond sensing layer was independently evaluated by capacitance measurements and alpha particle detection experiments. The MD sensitivity, measured at the PTW calibration laboratory, was also used to calculate the device active volume thickness. An average active surface area diameter of (2.19 ± 0.02) mm was evaluated by 2D maps and response profiles of all the MDs. Average active volume thicknesses of (1.01 ± 0.13) μm and (0.97 ± 0.14) μm were derived by capacitance and sensitivity measurements, respectively. The obtained results are well in agreement with the nominal values reported in the manufacturer dosimeter specifications. A homogeneous response was observed over the whole device active area. Besides the one from the device active volume, no contributions from other components of the housing nor from encapsulation materials were observed in the 2D response maps. The

  9. [Method for determination of radiation effects in cosmonauts by board dosimeter readings made during orbital mission].

    PubMed

    Kolomenskiĭ, A V; Petrov, V M; Shafirkin, A V

    1998-01-01

    A technique for calculating the SS MIR absorbed doses from the galactic cosmic rays, protons of the Earth's radiation belts and solar flares is described. Calculated daily doses for different compartments along the MIR main axis are compared with doses calculated for the location of board radiometer R-16 in various periods of solar activity. Maximal doses in MIR compartments (in the absence of phantom) were compared with the doses in referential depths of a spherical phantom representing the blood forming tissue, skin, enteric epithelium, and the absorbed dose in the dosimeter location. This comparison allows more precise estimation of radiation hazard to cosmonauts in space flight.

  10. Accurate calibration of a polymer gel dosimeter with a plastic scintillation detector.

    PubMed

    Tremblay, Nicolas M; Hubert-Tremblay, Vincent; Bujold, Rachel; Beddar, A Sam; Beaulieu, Luc; Lepage, Martin

    2011-05-01

    Three dimensional dose polymer gel dosimetry measurements provide unique information on sophisticated dose distributions. In this study, the authors propose a novel method to improve the accuracy of polymer gel dosimeters by inserting a plastic scintillation detector (PSD) to provide a dose reference. PSD dosimeters were calibrated using chromatic deconvolution and then inserted into polyacrylanide gel (PAG) dosimeters. The gel and the PSDs were immersed into water and irradiated with 6 MV wedge filtered beams to obtain a wide range of dose variation. Calibration vials containing the same gel were also irradiated to generate a standard calibration curve. The distribution of magnetic nuclear transverse relaxation rate (R2) values of the gel was determined with a multislice multiecho MRI sequence at 1.5 T. Another calibration curve was obtained by assigning the R2 values in the gel surrounding the scintillators to the dose determined by the PSDs. A reference calibration point from a PSD located in a low dose gradient area served to correct the standard calibration method yielding three novel calibration methods. The results were compared with EBT2 GAFCHROMIC film measurements acquired in the same condition and with the Pinnacle3 treatment planning dose calculations, The mean absolute error of the standard calibration method ranged from 6.1 to 12.4%. The corresponding gamma index (3%/3 mm distance to agreement) criterion was satisfied for only 56% of the pixels in the middle slice of the gel compared to Pinnacle3 dose calculations and to EBT2 film measurements in the center part of the field. Calibration methods using a PSD reduced the mean absolute error to less than 4%; this value was under 2.6% for one of the three methods. In that case, 98% of the pixels satisfied the gamma index criterion. The accuracy of PAG dosimeters may be highly improved using one reference dose point measurement using a plastic scintillation detector. The best calibration procedure

  11. NUCLEAR RADIATION DOSIMETER USING COMPOSITE FILTER AND A SINGLE ELEMENT FILTER

    DOEpatents

    Storm, E.; Shlaer, S.

    1964-04-21

    A nuclear radiation dosimeter is described that uses, in combination, a composite filter and a single element filter. The composite filter contains a plurality of comminuted metals having K-edges evenly distributed over the energy range of interest and the quantity of each of the metals is selected to result in filtering in an amount inversely proportional to the sensitivity of the film in the range over l00 kev. A copper filter is used that has a thickness to contribute the necessary additional correction in the interval between 40 and 100 kev. (AEC)

  12. Thin CaSO4:Dy thermoluminescent dosimeters for calibration of 90Sr+90Y applicators.

    PubMed

    Antonio, Patrícia L; Oliveira, Mércia L; Caldas, Linda V E

    2012-04-01

    Clinical applicators are used in brachytherapy to treat superficial lesions of skin and eye. They should be periodically calibrated according to quality control programs and international recommendations. Thin CaSO(4):Dy thermoluminescent dosimeters were used to calibrate various applicators with a dermatological applicator as a reference. The obtained absorbed dose rates were compared with those quoted in their calibration certificates. Depth-dose curves were constructed for all the applicators. A mail dosimetry system was developed for calibration of clinical applicators. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Investigating the accuracy of microstereotactic-body-radiotherapy utilizing anatomically accurate 3D printed rodent-morphic dosimeters

    SciTech Connect

    Bache, Steven T.; Juang, Titania; Belley, Matthew D.; Koontz, Bridget F.; Yoshizumi, Terry T.; Kirsch, David G.; Oldham, Mark; Adamovics, John

    2015-02-15

    Purpose: Sophisticated small animal irradiators, incorporating cone-beam-CT image-guidance, have recently been developed which enable exploration of the efficacy of advanced radiation treatments in the preclinical setting. Microstereotactic-body-radiation-therapy (microSBRT) is one technique of interest, utilizing field sizes in the range of 1–15 mm. Verification of the accuracy of microSBRT treatment delivery is challenging due to the lack of available methods to comprehensively measure dose distributions in representative phantoms with sufficiently high spatial resolution and in 3 dimensions (3D). This work introduces a potential solution in the form of anatomically accurate rodent-morphic 3D dosimeters compatible with ultrahigh resolution (0.3 mm{sup 3}) optical computed tomography (optical-CT) dose read-out. Methods: Rodent-morphic dosimeters were produced by 3D-printing molds of rodent anatomy directly from contours defined on x-ray CT data sets of rats and mice, and using these molds to create tissue-equivalent radiochromic 3D dosimeters from Presage. Anatomically accurate spines were incorporated into some dosimeters, by first 3D printing the spine mold, then forming a high-Z bone equivalent spine insert. This spine insert was then set inside the tissue equivalent body mold. The high-Z spinal insert enabled representative cone-beam CT IGRT targeting. On irradiation, a linear radiochromic change in optical-density occurs in the dosimeter, which is proportional to absorbed dose, and was read out using optical-CT in high-resolution (0.5 mm isotropic voxels). Optical-CT data were converted to absolute dose in two ways: (i) using a calibration curve derived from other Presage dosimeters from the same batch, and (ii) by independent measurement of calibrated dose at a point using a novel detector comprised of a yttrium oxide based nanocrystalline scintillator, with a submillimeter active length. A microSBRT spinal treatment was delivered consisting of a 180

  14. Application of clear polymethylmethacrylate dosimeter Radix W to a few MeV electron in radiation processing

    NASA Astrophysics Data System (ADS)

    Seito, Hajime; Ichikawa, Tatsuya; Hanaya, Hiroaki; Sato, Yoshishige; Kaneko, Hirohisa; Haruyama, Yasuyuki; Watanabe, Hiroshi; Kojima, Takuji

    2009-11-01

    Characteristics of clear PMMA dosimeter (Radix W) were studied for electron irradiation and compared with the response for gamma irradiation. The dose-response curves were nearly linear up to 30 kGy and become sublinear at higher doses. The radiation-induced absorbance was reduced with 6% within 4 h after irradiation. Dose comparisons were performed for 2, 3, 4 and 5 MeV electron irradiation using cellulose triacetate dosimeter (CTA) (FTR-125) and Radix W dosimeters which were independently calibrated for 2 MeV electrons and 60Co gamma-rays using calorimeter and ionizing chamber, respectively. The doses estimated by CTA and Radix W were different by about 20%. The magnitude of this difference was, however, independent of electron energy.

  15. Investigating the accuracy of microstereotactic-body-radiotherapy utilizing anatomically accurate 3D printed rodent-morphic dosimeters

    PubMed Central

    Bache, Steven T.; Juang, Titania; Belley, Matthew D.; Koontz, Bridget F.; Adamovics, John; Yoshizumi, Terry T.; Kirsch, David G.; Oldham, Mark

    2015-01-01

    Purpose: Sophisticated small animal irradiators, incorporating cone-beam-CT image-guidance, have recently been developed which enable exploration of the efficacy of advanced radiation treatments in the preclinical setting. Microstereotactic-body-radiation-therapy (microSBRT) is one technique of interest, utilizing field sizes in the range of 1–15 mm. Verification of the accuracy of microSBRT treatment delivery is challenging due to the lack of available methods to comprehensively measure dose distributions in representative phantoms with sufficiently high spatial resolution and in 3 dimensions (3D). This work introduces a potential solution in the form of anatomically accurate rodent-morphic 3D dosimeters compatible with ultrahigh resolution (0.3 mm3) optical computed tomography (optical-CT) dose read-out. Methods: Rodent-morphic dosimeters were produced by 3D-printing molds of rodent anatomy directly from contours defined on x-ray CT data sets of rats and mice, and using these molds to create tissue-equivalent radiochromic 3D dosimeters from Presage. Anatomically accurate spines were incorporated into some dosimeters, by first 3D printing the spine mold, then forming a high-Z bone equivalent spine insert. This spine insert was then set inside the tissue equivalent body mold. The high-Z spinal insert enabled representative cone-beam CT IGRT targeting. On irradiation, a linear radiochromic change in optical-density occurs in the dosimeter, which is proportional to absorbed dose, and was read out using optical-CT in high-resolution (0.5 mm isotropic voxels). Optical-CT data were converted to absolute dose in two ways: (i) using a calibration curve derived from other Presage dosimeters from the same batch, and (ii) by independent measurement of calibrated dose at a point using a novel detector comprised of a yttrium oxide based nanocrystalline scintillator, with a submillimeter active length. A microSBRT spinal treatment was delivered consisting of a 180

  16. SU-E-I-09: Application of LiF:Mg,Cu (TLD-100H) Dosimeters for in Diagnostic Radiology

    SciTech Connect

    Sina, S; Zeinali, B; Karimipourfard, M; Lotfalizadeh, F; Sadeghi, M; Faghihi, R

    2014-06-01

    Purpose: Accurate dosimetery is very essential in diagnostic radiology. The goal of this study is to verify the application of LiF:Mg,Cu,P (TLD100H) in obtaining the Entrance skin dose (ESD) of patients undergoing diagnostic radiology. The results of dosimetry performed by TLD-100H, were compared with those obtained by TLD100, which is a common dosimeter in diagnostic radiology. Methods: In this study the ESD values were measured using two types of Thermoluminescence dosimeters (TLD-100, and TLD-100H) for 16 patients undergoing diagnostic radiology (lumbar spine imaging). The ESD values were also obtained by putting the two types of TLDs at the surface of Rando phantom for different imaging techniques and different views (AP, and lateral). The TLD chips were annealed with a standard procedure, and the ECC values for each TLD was obtained by exposing the chips to equal amount of radiation. Each time three TLD chips were covered by thin dark plastic covers, and were put at the surface of the phantom or the patient. The average reading of the three chips was used for obtaining the dose. Results: The results show a close agreement between the dose measuered by the two dosimeters.According to the results of this study, the TLD-100H dosimeters have higher sensitivities (i.e.signal(nc)/dose) than TLD-100.The ESD values varied between 2.71 mGy and 26.29 mGy with the average of 11.89 mGy for TLD-100, and between 2.55 mGy and 27.41 mGy with the average of 12.32 mGy for measurements. Conclusion: The TLD-100H dosimeters are suggested as effective dosimeters for dosimetry in low dose fields because of their higher sensitivities.

  17. MOSFET dosimeter depth-dose measurements in heterogeneous tissue-equivalent phantoms at diagnostic x-ray energies

    SciTech Connect

    Jones, A.K.; Pazik, F.D.; Hintenlang, D.E.; Bolch, W.E.

    2005-10-15

    The objective of the present study was to explore the use of the TN-1002RD metal-oxide-semiconductor field effect transistor (MOSFET) dosimeter for measuring tissue depth dose at diagnostic photon energies in both homogeneous and heterogeneous tissue-equivalent materials. Three cylindrical phantoms were constructed and utilized as a prelude to more complex measurements within tomographic physical phantoms of pediatric patients. Each cylindrical phantom was constructed as a stack of seven 5-cm-diameter and 1-cm-thick discs of materials radiographically representative of either soft tissue (S), bone (B), or lung tissue (L) at diagnostic photon energies. In addition to a homogeneous phantom of soft tissue (SSSSSSS), two heterogeneous phantoms were constructed: SSBBSSS and SBLLBSS. MOSFET dosimeters were then positioned at the interface of each disc, and the phantoms were then irradiated at 66 kVp and 200 mAs. Measured values of absorbed dose at depth were then compared to predicated values of point tissue dose as determined via Monte Carlo radiation transport modeling. At depths exceeding 2 cm, experimental results matched the computed values of dose with high accuracy regardless of the dosimeter orientation (epoxy bubble facing toward or away from the x-ray beam). Discrepancies were noted, however, between measured and calculated point doses near the surface of the phantom (surface to 2 cm depth) when the dosimeters were oriented with the epoxy bubble facing the x-ray beam. These discrepancies were largely eliminated when the dosimeters were placed with the flat side facing the x-ray beam. It is therefore recommended that the MOSFET dosimeters be oriented with their flat sides facing the beam when they are used at shallow depths or on the surface of either phantoms or patients.

  18. SU-E-T-230: Measurement of Proton-Activated Positron Emission with PRESAGE 3-D Dosimeters

    SciTech Connect

    Carroll, M; Mawlawi, O; Ibbott, G; Adamovics, J

    2014-06-01

    Purpose: Measurement of positron emission following proton beam irradiation of a target has been studied as a method of in-vivo dosimetry. Relative dosimetry studies between a phantom and treatment plan are susceptible to range uncertainties from material heterogeneities and setup error. By using the radiochromic polyurethane dosimeter PRESAGE, we can correlate the proton dose distribution to the PET activity measurement within a single detector. The PRESAGE formulation used was developed for high-LET proton radiotherapy, has similar density and RLSP to tissue, and consists of a greater carbon component, which gives it a higher positron signal than many other 3D detectors. Methods: Three cylindrical PRESAGE dosimeters were irradiated semi-uniformly to 500 cGy with 180- MeV protons. The beam was directed along the dosimeter axis and delivered a 2-cm SOBP at the center of the dosimeter. The dosimeters were rushed to a nearby PET/CT where imaging began within 15 minutes, less than a single half-life of 11C. A 3-hr measurement captured the full activation decay. Afterwards, the dose profiles were measured by optical-CT. A direct comparison between the measured dose and the positron emission was performed using CERR software. Results: The correlations between dose distributions and PET activity were consistent with previous studies in that the proximal region of the SOBP displayed the highest activity. The spatial distributions between the dose and activity were similar. Along the central axis of the beam, we found a shift in the distal 80% of 1 cm. The lateral profile showed good agreement between dose and activity. PET imaging times between 30-min and 3-hrs showed <5% discrepancy. Conclusion: PRESAGE dosimeters offer a strong and unique potential to accurately correlate dosimetric and PET activation information. Implementation in an anthropomorphic phantom could be used to study representative treatment plans. NIH grant 5R01CA100835.

  19. Performance Evaluation of a Multichannel All-In-One Phantom Dosimeter for Dose Measurement of Diagnostic X-ray Beam.

    PubMed

    Jeon, Hyesu; Yoo, Wook Jae; Shin, Sang Hun; Kwon, Guwon; Kim, Mingeon; Kim, Hye Jin; Song, Young Beom; Jang, Kyoung Won; Youn, Won Sik; Lee, Bongsoo

    2015-11-11

    We developed a multichannel all-in-one phantom dosimeter system composed of nine sensing probes, a chest phantom, an image intensifier, and a complementary metal-oxide semiconductor (CMOS) image sensor to measure the dose distribution of an X-ray beam used in radiation diagnosis. Nine sensing probes of the phantom dosimeter were fabricated identically by connecting a plastic scintillating fiber (PSF) to a plastic optical fiber (POF). To measure the planar dose distribution on a chest phantom according to exposure parameters used in clinical practice, we divided the top of the chest phantom into nine equal parts virtually and then installed the nine sensing probes at each center of the nine equal parts on the top of the chest phantom as measuring points. Each scintillation signal generated in the nine sensing probes was transmitted through the POFs and then intensified by the image intensifier because the scintillation signal normally has a very low light intensity. Real-time scintillation images (RSIs) containing the intensified scintillation signals were taken by the CMOS image sensor with a single lens optical system and displayed through a software program. Under variation of the exposure parameters, we measured RSIs containing dose information using the multichannel all-in-one phantom dosimeter and compared the results with the absorbed doses obtained by using a semiconductor dosimeter (SCD). From the experimental results of this study, the light intensities of nine regions of interest (ROI) in the RSI measured by the phantom dosimeter were similar to the dose distribution obtained using the SCD. In conclusion, we demonstrated that the planar dose distribution including the entrance surface dose (ESD) can be easily measured by using the proposed phantom dosimeter system.

  20. Performance Evaluation of a Multichannel All-In-One Phantom Dosimeter for Dose Measurement of Diagnostic X-ray Beam

    PubMed Central

    Jeon, Hyesu; Yoo, Wook Jae; Shin, Sang Hun; Kwon, Guwon; Kim, Mingeon; Kim, Hye Jin; Song, Young Beom; Jang, Kyoung Won; Youn, Won Sik; Lee, Bongsoo

    2015-01-01

    We developed a multichannel all-in-one phantom dosimeter system composed of nine sensing probes, a chest phantom, an image intensifier, and a complementary metal-oxide semiconductor (CMOS) image sensor to measure the dose distribution of an X-ray beam used in radiation diagnosis. Nine sensing probes of the phantom dosimeter were fabricated identically by connecting a plastic scintillating fiber (PSF) to a plastic optical fiber (POF). To measure the planar dose distribution on a chest phantom according to exposure parameters used in clinical practice, we divided the top of the chest phantom into nine equal parts virtually and then installed the nine sensing probes at each center of the nine equal parts on the top of the chest phantom as measuring points. Each scintillation signal generated in the nine sensing probes was transmitted through the POFs and then intensified by the image intensifier because the scintillation signal normally has a very low light intensity. Real-time scintillation images (RSIs) containing the intensified scintillation signals were taken by the CMOS image sensor with a single lens optical system and displayed through a software program. Under variation of the exposure parameters, we measured RSIs containing dose information using the multichannel all-in-one phantom dosimeter and compared the results with the absorbed doses obtained by using a semiconductor dosimeter (SCD). From the experimental results of this study, the light intensities of nine regions of interest (ROI) in the RSI measured by the phantom dosimeter were similar to the dose distribution obtained using the SCD. In conclusion, we demonstrated that the planar dose distribution including the entrance surface dose (ESD) can be easily measured by using the proposed phantom dosimeter system. PMID:26569252

  1. SU-E-T-353: Effects of Time and Temperature On a Potential Reusable 3D Dosimeter

    SciTech Connect

    Juang, T; Miles, D; Crockett, E; Adamovics, J; Oldham, M

    2015-06-15

    Purpose: Preliminary studies of a novel, optically-clearing PRESAGE 3D dosimeter formulation (Presage-RU) demonstrated potential reusability. This study investigates the effects of time and temperature on the accuracy and reusability of Presage-RU, and reports on progress toward developing a reusable 3D dosimeter. Methods: Presage-RU was cast as small volume samples (1×1×4.5cm). The effect of dose response sensitivity with reirradiation and time was evaluated by irradiating samples from 0–10Gy, measuring change in optical density (ΔOD), clearing at room temperature (RT) (5–7 days to fully clear), and then repeating for a total of 5 irradiations. Effects of heating on clearing rate were investigated by irradiating samples to 8Gy, then tracking measurements with samples held at RT, 35°C, and 45°C. Two cylindrical dosimeters (11cm diameter, 9.5cm length) were evaluated for dosimetric accuracy when stored at RT and −3°C prior to irradiation. Plans delivered were 2 overlapping AP fields (RT) and VMAT (-3°C). Results: Heating the dosimeters reduced the clearing half-life from 16.3h at RT to 5.8h (35°C) and 5.1h (45°C), but also increased background ΔOD by 1.7x (35°C) and 2.3x (45°C). Reductions in dose response were more closely linked to age than reirradiation, and storage at RT showed pronounced desensitization from dosimeter edges. These results suggest desensitization from oxygen diffusion. It should be noted that atmospheric diffusion into the dosimeter is not seen in standard, single-use PRESAGE, and is likely caused by differences in the Presage-RU polyurethane matrix. The dosimeter kept in cold storage, however, showed no evidence of desensitization and exhibited accuracy on par with standard PRESAGE with a 3%/3mm 3D gamma passing rate of 98.1%. Conclusions: Presage-RU is sensitive to storage temperatures and time, both of which affect oxygen diffusion and subsequent desensitization. Development shows promising progress with further formulation

  2. Use of a spherical albedo system for correcting the readings of albedo dosimeters in JINR phasotron neutron radiation fields

    NASA Astrophysics Data System (ADS)

    Mokrov, Yu. V.; Morozova, S. V.

    2014-03-01

    Results of calibrating a spherical albedo system in the radiation fields of a Pu-Be radionuclide neutron source are presented. It is shown that it can be used for correcting the readings of the DVGN-01 albedo dosimeter. The results of measurements with the system in JINR phasotron neutron fields for the purpose of correcting the DVGN-01 readings in these fields are given. The values of the correction factors for DVGN-01 albedo dosimeters when used in personnel neutron dosimetry (PD) on the JINR phasotron are determined.

  3. A cyanocobalamin dosimeter for monitoring gamma-radiation doses of 0.1-2 kGy

    NASA Astrophysics Data System (ADS)

    Maged, A. F.; Hamza, M. S. A.; Saad, E. A.

    1997-08-01

    A simple dosimeter is described for measuring gamma-ray doses useful for insect sterilization, seed-sprouting inhibition and food shelf-life extensions. The red aqueous solution of cyanocobalamin (B 12) before irradiation, assumes a stable yellow color when irradiated. It shows a linear response of absorbance decrease with the dose over the range of 0.1-2.0 kGy when the concentration of cyanocobalamin is equal 0.09 mM. The radiation-induced color is analyzed spectrophotometrically at the maximum absorption band (361 nm). The absorption spectra, dose response and post-irradiation stability of the dosimeter are discussed.

  4. Effect of Electron-Beam Irradiation on Organic Semiconductor and Its Application for Transistor-Based Dosimeters.

    PubMed

    Kim, Jae Joon; Ha, Jun Mok; Lee, Hyeok Moo; Raza, Hamid Saeed; Park, Ji Won; Cho, Sung Oh

    2016-08-03

    The effects of electron-beam irradiation on the organic semiconductor rubrene and its application as a dosimeter was investigated. Through the measurements of photoluminescence and the ultraviolet photoelectron spectroscopy, we found that electron-beam irradiation induces n-doping of rubrene. Additionally, we fabricated rubrene thin-film transistors with pristine and irradiated rubrene, and discovered that the decrease in transistor properties originated from the irradiation of rubrene and that the threshold voltages are shifted to the opposite directions as the irradiated layers. Finally, a highly sensitive and air-stable electron dosimeter was fabricated based on a rubrene transistor.

  5. Evaluation of the response to xenon-133 radiations by thermoluminescent dosimeters used during the accident at Three Mile Island.

    PubMed

    Riley, R J; Zanzonico, P B; Masterson, M E; St Germain, J M; Laughlin, J S

    1982-03-01

    An evaluation is presented of the accuracy and sensitivity of three types of TLD's used during the accident at the Three Mile Island Nuclear Station. This evaluation indicated that, due to the method of calibration, all the dosimeters over-responded to 133Xe radiations. The response ranged from slightly above unity to almost two. Exposures of the TLD's were of two types, namely, the characteristic X-rays either were or were not filtered from the beam. The angular sensitivity of the dosimeters is also reported.

  6. Angular dependence of optical fibre thermoluminescent dosimeters irradiated using kilo- and megavoltage X-rays

    NASA Astrophysics Data System (ADS)

    Moradi, F.; Ung, N. M.; Mahdiraji, G. A.; Khandaker, M. U.; Entezam, A.; See, M. H.; Taib, N. A.; Amin, Y. M.; Bradley, D. A.

    2017-06-01

    Prior investigation of the suitability of optical fibres as thermoluminescent dosimeters for diagnostic and therapeutic radiation beams has not included detailed study of the effect of beam angulation. Present study of such response has made use of optical fibre of cylindrical shape, exposed to 30 kVp photons from an X-ray tube and a 6 MV photon beam from a linear accelerator. The effect of the irradiation medium was also studied, comparing response free-in-air against on-surface and in-depth irradiations through use of solid-water™ phantom. Standard optical fibre (ø =125 μm) shows non-uniform response to beams delivered at different incident angles. Monte Carlo simulation provided support for the experimental results, also obtaining absorbed dose in the fibres. The results of free-in-air condition simulated with mono-energy beam show angle-independent response for photons within the energy range 100-500 keV, while dependency has been observed for beam energies of <100 keV and >500 keV. Experimentally, the angular dependency up to 35% is observed in 30 kVp free-in-air, while in 6 MeV beam, this is reduced to 20%, 10%, and 3% in free-in-air, on phantom surface, and in-depth conditions, respectively. The observations have been justified by considering the range of secondary electrons in the dosimeter and the effect of scattered radiation.

  7. Feasibility study of CaSO4:Tb,Yb as a thermoluminescent dosimeter

    NASA Astrophysics Data System (ADS)

    Junot, Danilo O.; Santos, Max A.; Chagas, Marcos A. P.; Couto dos Santos, Marcos A.; Nunes, Luiz A. O.; Souza, Divanizia N.

    2014-02-01

    A new composite based on CaSO4, using terbium as dopant and ytterbium as co-dopant (CaSO4:Tb,Yb), was developed for employment as a thermoluminescent (TL) dosimeter. The crystals used in this work were grown using a production route based on the Yamashita method (Yamashita et al., 1968). Crystal powder was calcined at 600 °C for 1 h. Pellets were made by adding commercial and colorless glass to improve physical resistance and sintered at 700 °C for 6 h. All samples were irradiated by a beta source (90Sr/90Y) and received doses from 1 Gy to 5 Gy. TL analyses have been performed and characteristics such as sensitivity, reproducibility, linearity, and fading have been studied. The CaSO4:Tb,Yb pellets glow curves presented two peaks, the first at around 115 °C, and the second at around 200 °C. The highest intensity was shown for CaSO4:Tb,Yb with a concentration of 0.1 mol% of Tb and Yb together. In all the samples the TL response was proportional to the absorbed dose. Therefore, the CaSO4:Tb,Yb has potential to be used as a thermoluminescent dosimeter.

  8. Response of biological uv dosimeters to the simulated extraterrestrial uv radiation

    NASA Astrophysics Data System (ADS)

    Bérces, A.; Rontó, G.; Kerékgyártó, T.; Kovács, G.; Lammer, H.

    In the Laboratory polycrystalline uracil thin layer and bacteriophage T7 detectors have been developed for UV dosimetry on the EarthSs surface. Exponential response of the uracil polycrystal has been detected both by absorption spectroscopy and measurements of the refractive index under the influence of terrestrial solar radiation or using UV-C sources. In UV biological dosimetry the UV dose scale is additive starting at a value of zero according to the definition of CIE (Technical Report TC-6-18). The biological dose can be defined by a measured end-effect. In our dosimeters (phage T7 and uracil dosimeter) exposed to natural (terrestrial) UV radiation the proportion of pyrimidin photoproducts among the total photoproducts is smaller than 0.1 and the linear correlation between the biological and physical dose is higher than 0.9. According to the experimental data this linear relationship is often not valid. We observed that UV radiation did not only induce dimerisation but shorter wavelengths caused monomerisation of pyrimidin dimers. Performing the irradiation in oxygen free environment and using a Deuterium lamp as UV source, we could increase monomerisation against dimerisation thus the DNA-based dosimetrySs additivity rule is not fulfilled in these conditions. In this study we will demonstrate those non-linear experiments which constitute the basis of our biological experiments on the International Space Station.

  9. A prototype optical-CT system for PRESAGE 3D dosimeter readout

    NASA Astrophysics Data System (ADS)

    Miles, Devin; Yoon, Paul; Kodra, Jacob; Adamovics, John; Oldham, Mark

    2017-05-01

    This work introduces the Duke Integrated-lens Optical Scanner (DIOS), a prototype optical-CT system designed for convenient and low-cost readout of PRESAGE 3D dosimeters. A key novelty of the DIOS is the incorporation of a multi-purpose light-collimating tank (the LC-tank). The LC-tank collimates light from a point source, maintains parallel ray geometry through a dosimeter mounted inside the tank, and refocuses emergent light onto a CCD detector. A second purpose is to dramatically reduce the amount of refractive matched fluid required in prior optical-CT scanners. This is achieved by substituting large quantities of refractive-matched fluid with solid RI-matched polyurethane. The advantages of DIOS include eliminating the need for expensive telecentric lenses, and eliminating the impracticality of large volumes of RI matched fluid. The DIOS is potentially more susceptible to stray-light artifacts. Preliminary phantom testing shows promising agreement between PRESAGE/DIOS readout and prior commissioned optical-CT scanners, as well as with Eclipse dose calculations.

  10. A preliminary study of the thermal measurement with nMAG gel dosimeter by MRI

    NASA Astrophysics Data System (ADS)

    Chuang, Chun-Chao; Shao, Chia-Ho; Shih, Cheng-Ting; Yeh, Yu-Chen; Lu, Cheng-Chang; Chuang, Keh-Shih; Wu, Jay

    2014-11-01

    The methacrylic acid (nMAG) gel dosimeter is an effective tool for 3-dimensional quality assurance of radiation therapy. In addition to radiation induced polymerization effects, the nMAG gel also responds to temperature variation. In this study, we proposed a new method to evaluate the thermal response in thermal therapy using nMAG gel and magnetic resonance image (MRI) scans. Several properties of nMAG have been investigated including the R2 relaxation rate, temperature sensitivity, and temperature linearity of the thermal dose response. nMAG was heated by the double-boiling method in the range of 37-45 °C. MRI scans were performed with the head coil receiver. The temperature to R2 response curve was analyzed and simple linear regression was performed with an R-square value of 0.9835. The measured data showed a well inverse linear relationship between R2 and temperature. We conclude that the nMAG polymer gel dosimeter shows great potential as a technique to evaluate the temperature rise during thermal surgery.

  11. The use of commercial glass as a potential gamma accidental dosimeter through the absorption spectra

    NASA Astrophysics Data System (ADS)

    Kharita, M. H.; Yousef, S.; Bakr, S.

    2012-05-01

    Various types of commercial glass (ordinary windows, cathode ray tubes, glass kitchenware) have been studied as potential accidental radiation dosimeters. The proposed method utilizes the changes in the glasses' absorption spectra as a result of irradiation. A 60Co gamma irradiation cell has been used to irradiate samples with doses ranging from 5 to 200 Gy. The transmittance was measured using a photospectrometer (UV-visible spectrometry). The results demonstrate that the transmittance spectra of most of the glass samples change in linear proportion to the exposure dose. Moreover, the study considers the fading effect on the absorption spectra of the irradiated samples for fading times up to 100 days at room temperature. The results of this work demonstrate that several widely used types of glass can be used as high-dose accidental dosimeters for doses ranging between 8 and 200 Gy. A reasonable calibration line can be established for any irradiated glass sample by heating, re-irradiating with standard doses and measuring the related absorption coefficient. Further investigations are needed to decrease the minimum detectable dose of the proposed method and to study the effect of glass composition on radiation response.

  12. Investigation of a pulsed current annealing method in reusing MOSFET dosimeters for in vivo IMRT dosimetry

    SciTech Connect

    Luo, Guang-Wen; Qi, Zhen-Yu Deng, Xiao-Wu; Rosenfeld, Anatoly

    2014-05-15

    Purpose: To explore the feasibility of pulsed current annealing in reusing metal oxide semiconductor field-effect transistor (MOSFET) dosimeters forin vivo intensity modulated radiation therapy (IMRT) dosimetry. Methods: Several MOSFETs were irradiated atd{sub max} using a 6 MV x-ray beam with 5 V on the gate and annealed with zero bias at room temperature. The percentage recovery of threshold voltage shift during multiple irradiation-annealing cycles was evaluated. Key dosimetry characteristics of the annealed MOSFET such as the dosimeter's sensitivity, reproducibility, dose linearity, and linearity of response within the dynamic range were investigated. The initial results of using the annealed MOSFETs for IMRT dosimetry practice were also presented. Results: More than 95% of threshold voltage shift can be recovered after 24-pulse current continuous annealing in 16 min. The mean sensitivity degradation was found to be 1.28%, ranging from 1.17% to 1.52%, during multiple annealing procedures. Other important characteristics of the annealed MOSFET remained nearly consistent before and after annealing. Our results showed there was no statistically significant difference between the annealed MOSFETs and their control samples in absolute dose measurements for IMRT QA (p = 0.99). The MOSFET measurements agreed with the ion chamber results on an average of 0.16% ± 0.64%. Conclusions: Pulsed current annealing provides a practical option for reusing MOSFETs to extend their operational lifetime. The current annealing circuit can be integrated into the reader, making the annealing procedure fully automatic.

  13. On the discovery of some phenomena in electrochemical etching of polymeric dosimeters

    NASA Astrophysics Data System (ADS)

    Sohrabi, M.

    1987-03-01

    Although electrochemical etching (ECE) of polymeric dosimeters has been advancing for over a decade, some phenomena such as "dielectric loss", "electro-osmosis", "dielectrophoresis" and "electrostriction" have been recently discovered and proved to exist in ECE ehich are reported and discussed in this paper. The "dielectric loss" mechanisms lead to an internal heating effect which heats up the etchant effectively with a rate per unit foil volume proportional to E2, f, and polymer loss index (ɛ' tan δ). Thus foil effective diameter, etchant volume, and the chamber's external insulation were introduced as new important parameters in ECE especially at high applied field conditions. The combined effects of "electro-osmotic pressure" and "dielectrophoretic forces" are discussed to cause "water tree" microstructure of tracks in CR-39 with a "water bubble" at the center which has a temporary nature, and "electrostriction" seems to cause dimensional changes of some foils under ECE. In this paper, the existence of the above phenomena in ECE and their impacts on the ECE parameters as well as neutron dosimetry responses and track shapes in polycarbonate and CR-39 neutron dosimeters under different applied field conditions are demonstrated and discussed.

  14. Beta planar source quality assurance with the Fricke xylenol gel dosimeter

    NASA Astrophysics Data System (ADS)

    Alva-Sánchez, Mirko S.; de Oliveira, Lucas N.; Petchevist, Paulo C.; Moreira, Marco V.; de Almeida, Adelaide

    2014-03-01

    Beta therapy is employed in post surgery to treat lesions such as pterygia, keloid and glioblastoma. The beta source most used for these purposes is 90/90Y, whose quality assurance is a challenge, because the detectors currently used for this evaluation do not satisfy the spatial resolution, the effective atomic number and the tissue equivalent conditions. The Fricke xylenol gel (FXG) has been used in several applications in radiotherapy due to its better characteristics. This dosimeter is associated with the Fe(II) to Fe(III) oxidation, post ionizing irradiation, being the final Fe(III) concentration linearly depended on the absorbed dose. The goal of this present work is to show that the FXG, with atomic effective number (Zeff) of 7.75 and high resolution (<1 mm), accomplishes quality assurance for rectangular and square planar 90Sr/90Y sources. In order to demonstrate the quality assurance, calibration curves, percentage depth dose and beam profile from exposed FXG samples were analyzed and from these results, we demonstrate the potential use of the FXG dosimeter for beta source quality control.

  15. Long-term stability of radiotherapy dosimeters calibrated at the Polish Secondary Standard Dosimetry Laboratory.

    PubMed

    Ulkowski, Piotr; Bulski, Wojciech; Chełmiński, Krzysztof

    2015-10-01

    Unidos 10001, Unidos E (10008/10009) and Dose 1 electrometers from 14 radiotherapy centres were calibrated 3-4 times over a long period of time, together with Farmer type (PTW 30001, 30013, Nuclear Enterprises 2571 and Scanditronix-Wellhofer FC65G) cylindrical ionization chambers and plane-parallel type chambers (PTW Markus 23343 and Scanditronix-Wellhofer PPC05). On the basis of the long period of repetitive establishing of calibration coefficients for the same electrometers and ionization chambers, the accuracy of electrometers and the long-term stability of ionization chambers were examined. All measurements were carried out at the same laboratory, by the same staff, according to the same IAEA recommendations. A good accuracy and long-term stability of the dosimeters used in Polish radiotherapy centres was observed. These values were within 0.1% for electrometers and 0.2% for the chambers with electrometers. Furthermore, these values were not observed to vary over time. The observations confirm the opinion that the requirement of calibration of the dosimeters more often than every 2 years is not justified. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Radiation-induced apoptosis in human lymphocytes: Potential as a biological dosimeter

    SciTech Connect

    Boreham, D.R.; Gale, K.L.; Maves, S.R.; Walker, J.A.; Morrison, D.P.

    1996-11-01

    We have tested the possibility of using apoptosis (programmed cell death) in human peripheral blood lymphocytes as a short-term biological dosimeter. Lymphocytes isolated from whole blood were irradiated in culture with 250 kVp x-rays or {sup 60}Co gamma rays. Two assays were used to measure apoptosis in lymphocytes after irradiation: in situ terminal deoxynucleotidyl transferase assay and fluorescence analysis of DNA unwinding assay. Similar qualitative and quantitative results were produced by the assays, supporting the notion that the fluorescence analysis of DNA unwinding assay measured DNA fragmentation associated with apoptosis. Induction of apoptosis in lymphocytes irradiated in vitro was proportional to dose and could be detected following exposures as low as 0.05 Gy. Lymphocytes irradiated in vitro was proportional to dose and could be detected following exposures as low as 0.05 Gy. Lymphocytes from individual donors had reproducible dose responses. There was, however, variation between donors. X-ray and gamma-ray exposures induced similar levels of apoptosis at similar doses. The induction kinetics of apoptosis in vitro indicate a maximum is reached about 72 h after irradiation. In conclusion, the in vitro experimental evidence indicates that radiation-induced apoptosis in human lymphocytes has the kinetics, sensitivity, and reproductibility to be a potential biological dosimeter. 29 refs., 5 figs.

  17. Use of MOSFET dosimeters to validate Monte Carlo radiation treatment calculation in an anthropomorphic phantom

    NASA Astrophysics Data System (ADS)

    Juste, Belén; Miró, R.; Abella, V.; Santos, A.; Verdú, Gumersindo

    2015-11-01

    Radiation therapy treatment planning based on Monte Carlo simulation provide a very accurate dose calculation compared to deterministic systems. Nowadays, Metal-Oxide-Semiconductor Field Effect Transistor (MOSFET) dosimeters are increasingly utilized in radiation therapy to verify the received dose by patients. In the present work, we have used the MCNP6 (Monte Carlo N-Particle transport code) to simulate the irradiation of an anthropomorphic phantom (RANDO) with a medical linear accelerator. The detailed model of the Elekta Precise multileaf collimator using a 6 MeV photon beam was designed and validated by means of different beam sizes and shapes in previous works. To include in the simulation the RANDO phantom geometry a set of Computer Tomography images of the phantom was obtained and formatted. The slices are input in PLUNC software, which performs the segmentation by defining anatomical structures and a Matlab algorithm writes the phantom information in MCNP6 input deck format. The simulation was verified and therefore the phantom model and irradiation was validated throughout the comparison of High-Sensitivity MOSFET dosimeter (Best medical Canada) measurements in different points inside the phantom with simulation results. On-line Wireless MOSFET provide dose estimation in the extremely thin sensitive volume, so a meticulous and accurate validation has been performed. The comparison show good agreement between the MOSFET measurements and the Monte Carlo calculations, confirming the validity of the developed procedure to include patients CT in simulations and approving the use of Monte Carlo simulations as an accurate therapy treatment plan.

  18. Radiation dosimeter

    DOEpatents

    Fox, Richard J.

    1983-01-01

    A radiation detector readout circuit is provided which produces a radiation dose-rate readout from a detector even though the detector output may be highly energy dependent. A linear charge amplifier including an output charge pump circuit amplifies the charge signal pulses from the detector and pumps the charge into a charge storage capacitor. The discharge rate of the capacitor through a resistor is controlled to provide a time-dependent voltage which when integrated provides an output proportional to the dose-rate of radiation detected by the detector. This output may be converted to digital form for readout on a digital display.

  19. Radiation dosimeter

    DOEpatents

    Fox, R.J.

    1981-09-01

    A radiation detector readout circuit is provided which produces a radiation dose-rate readout from a detector even through the detector output may be highly energy dependent. A linear charge amplifier including an output charge pump circuit amplifies the charge signal pulses from the detector and pumps the charge into a charge storage capacitor. The discharge rate of the capacitor through a resistor is controlled to provide a time-dependent voltage which when integrated provides an output proportional to the dose-rate of radiation detected by the detector. This output may be converted to digital form for readout on a digital display.

  20. Investigation of neutron converters for production of optically stimulated luminescence (OSL) neutron dosimeters using Al 2O 3:C

    NASA Astrophysics Data System (ADS)

    Mittani, J. C. R.; da Silva, A. A. R.; Vanhavere, F.; Akselrod, M. S.; Yukihara, E. G.

    2007-07-01

    This paper presents the optically stimulated luminescence (OSL) properties of neutron dosimeters in powder and in the form of pellets prepared with a mixture of Al 2O 3:C and neutron converters. The neutron converters investigated were high density polyethylene (HDPE), lithium fluoride (LiF), lithium fluoride 95% enriched with 6Li ( 6LiF), lithium carbonate 95% enriched with 6Li ( 6Li 2CO 3), boric acid enriched with 99% of 10B (H310BO) and gadolinium oxide (Gd 2O 3). The proportion of Al 2O 3:C and neutron converter in the mixture was varied to optimize the total OSL signal and neutron sensitivity. The neutron sensitivity and dose-response were determined for the OSL dosimeters using a bare 252Cf source and compared to the response of Harshaw TLD-600 and TLD-700 dosimeters ( 6LiF:Mg,Ti and 7LiF:Mg,Ti). The results demonstrate the possibility of developing an OSL dosimeter made of Al 2O 3:C powder and neutron converter with a neutron sensitivity (defined as the ratio between the 60Co equivalent gamma dose and the reference neutron absorbed dose) and neutron-gamma discrimination comparable to the TLD-600/TLD-700 combination. It was shown that the shape of the OSL decay curves varied with the type of the neutron converter, demonstrating the influence of the energy deposition mechanism and ionization density on the OSL process in Al 2O 3:C.