Science.gov

Sample records for personnel dosemeters conrad

  1. 1983 ORNL intercomparison of personnel neutron and gamma dosemeters

    SciTech Connect

    Swaja, R.E.; Sims, C.S.; Greene, R.T.

    1985-01-01

    The Ninth Personnel Dosimetry Intercomparison Study was conducted during April 19-21, 1983, at the Oak Ridge National Laboratory. Dosemeters from 33 participating agencies were mounted on water-filled polyethylene elliptical phantoms and exposed to a range of low-level dose equivalents (0.02-0.45 mSv gamma and 0.49-11.14 mSv neutron) which could be encountered during routine personnel monitoring in mixed radiation fields. The Health Physics Research Reactor served as the radiation source for six separate exposures which used four different shield conditions: unshielded and shielded with steel, steel/concrete, and concrete. Results of the neutron measurements indicate that it is not unusual for dose equivalent estimates made under the same conditions by different agencies to differ by more than a factor of 2. Albedo systems, which were the most popular neutron monitors in this study, provided the most accurate results with CR-39 recoil track being least accurate. Track and film neutron systems exhibited problems providing measurable indication of neutron exposure at dose equivalents of about 0.50 mSv. Gamma measurements showed that TLD and film systems generally overestimated dose equivalents in the mixed radiation fields with film exhibiting significant problems providing measurable indication of gamma exposure at dose equivalents lower than about 0.15 mSv. Under the conditions of this study in which exposures were carefully controlled and participants had information concerning exposure conditions and incident spectra prior to dosemeter analysis, only slightly more than half of all neutron and gamma dose equivalent estimates met regulatory accuracy standards relative to reference values. These results indicate that continued improvement of mixed-field personnel dosimetry is required by many participating organizations. 15 references, 30 tables.

  2. An estimate of the propagated uncertainty for a dosemeter algorithm used for personnel monitoring.

    PubMed

    Veinot, K G

    2015-03-01

    The Y-12 National Security Complex utilises thermoluminescent dosemeters (TLDs) to monitor personnel for external radiation doses. The TLD consist of four elements positioned behind various filters, and dosemeters are processed on site and input into an algorithm to determine worker dose. When processing dosemeters and determining the dose equivalent to the worker, a number of steps are involved, including TLD reader calibration, TLD element calibration, corrections for fade and background, and inherent sensitivities of the dosemeter algorithm. In order to better understand the total uncertainty in calculated doses, a series of calculations were performed using certain assumptions and measurement data. Individual contributions to the uncertainty were propagated through the process, including final dose calculations for a number of representative source types. Although the uncertainty in a worker's calculated dose is not formally reported, these calculations can be used to verify the adequacy of a facility's dosimetry process.

  3. Joseph Conrad: International Narrator

    ERIC Educational Resources Information Center

    Walker, George

    2004-01-01

    This article discusses the contribution made by Joseph Conrad's fictional writing to our understanding of cultural awareness. Never comfortable with his adopted English culture, Conrad used his experiences in different parts of the world during his career in the merchant navy to explore in his writing aspects of cultural dissonance and cultural…

  4. Joseph Conrad: International Narrator

    ERIC Educational Resources Information Center

    Walker, George

    2004-01-01

    This article discusses the contribution made by Joseph Conrad's fictional writing to our understanding of cultural awareness. Never comfortable with his adopted English culture, Conrad used his experiences in different parts of the world during his career in the merchant navy to explore in his writing aspects of cultural dissonance and cultural…

  5. Effect of short-term sensitivity loss in LiF:Mg,Cu,P thermoluminescent dosemeter and its implications on personnel dosimetry operations

    PubMed Central

    Romanyukha, Alexander; Delzer, Jeffrey A.; Grypp, Matthew D.; Williams, Anthony S.

    2016-01-01

    A short-term sensitivity loss in LiF:Mg,Cu,P thermoluminescent dosemeters (TLDs) was observed and is described. Its observation occurred during a pre-irradiation anneal with a slightly elevated maximum temperature (5–15°C), which causes notable under-response (5–10 %) of the subsequent read at the recommended time–temperature profile (TTP), which has a peak temperature of 260°C. A subsequent irradiation and reading using the recommended TTP showed partial or complete recovery of the TLD's sensitivity. To the best of our knowledge, there were no publications on possible implications of a one-time 5–15°C overheat of LiF:Mg,Cu,P TLDs during anneal. This is not unusual when several readers with some variations in their heating cycles are used to calibrate and process the same population of dosemeters. A special test to identify if a small uncontrolled overheating of a dosemeter element has occurred was developed and tested. Two practical implications of the effect of a short-term sensitivity loss in LiF:Mg,Cu,P, e.g. inconsistency in results of metrological traceability verification and reporting of false neutron doses, are described in detail. Simple indicators of a small uncontrolled overheating are provided. PMID:25767182

  6. Joseph Conrad's "Lord Jim": Reconsiderations

    ERIC Educational Resources Information Center

    Al-Haj, Ali Albashir Mohammed

    2014-01-01

    The present study aims at reconsidering critically Joseph Conrad's "Lord Jim." Joseph Conrad is a great master of English prose who writes normally of the sea, of the Eastern islands, of the English character as seen against a background of the exotic or faced with difficulties. The power of Conrad's feelings for Jim, as well as the…

  7. Comparison test of electronic dosemeters.

    PubMed

    Butterweck, G; Zimmerli, H P; Wernli, C

    2001-01-01

    To assist with a planned purchase of electronic dosemeters by the Swiss Federal Office for Civil Protection, the calibration laboratory of the Paul Scherrer Institute performed tests on 11 types of electronic dosemeters manufactured by 10 European and American companies. The technical specifications for the World Trade Organisation (WTO) tendering procedure were largely in accord with the specifications of the international standard IEC 61526. First tests were performed with samples from each type of dosemeter. The reproducibility of a dose of 0.1 mSv generated with 137Cs radiation at a dose rate of 2.1 mSv.h-1 was found adequate for all tested dosemeter types. The response for environmental levels of radiation showed a large variation, indicating insufficient background correction of some dosmeters. A very high dose rate of 10 Sv.h-1 provoked faulty dose readings for more than half of the tested dosemeters. Dosemeter response for low-energy photon radiation was satisfactory for two of the tested dosemeter types. Four dosemeter types were selected for extended technical tests. Three samples of each of these dosemeter types were purchased. For drop and temperature tests the specifications of the WTO tendering procedure outranged the specifications of the IEC standard. Whereas even at a temperature of -25 degrees C the tested dosemeters functioned normally, drops from a height of 2 m onto a wooden surface rendered the samples of two dosemeter types inoperative.

  8. INTERCOMPARISON OF EYE LENS DOSEMETERS.

    PubMed

    Behrens, R; Hupe, O; Busch, F; Denk, J; Engelhardt, J; Günther, K; Hödlmoser, H; Jordan, M; Strohmaier, J

    2016-03-23

    An intercomparison of eye lens dosemeters has been conducted in terms of the quantityHp(3). For the first time, besides photon radiation also beta radiation qualities were included. Three dosemeter types designed for the quantityHp(3) and ten forHp(0.07) took part in the intercomparison. As shown in a previous intercomparison for photon radiation only, the dosemeters designed forHp(0.07) and calibrated in terms ofHp(3) performed well in photon radiation fields. But for beta radiation, it turned out thatHp(0.07) dosemeters over-responded up to a factor of 5 000 (with respect to the trueHp(3) dose) in the medium beta energy range ((85)Kr with a beta endpoint energy of 0.69 MeV), while someHp(3) dosemeters performed quite well. For medium (57 keV) and high (662 keV) energy photon radiation, all dosemeter types showed response values well within the trumpet curve according to the current draft of ISO 14146.

  9. Conrad's Quarrel with Politics in "Nostromo."

    ERIC Educational Resources Information Center

    Schwarz, Daniel R.

    1997-01-01

    Argues that Joseph Conrad's political novels belie the sweeping and vague rhetoric sometimes used to describe them. States that Conrad, disillusioned with materialism in his political novels, imagines that "industrialism and commercialism" may foster wars between democracies. Contends Conrad's interest is at least divided between a…

  10. Joseph Conrad's tormented Rescue (fantasy).

    PubMed

    Freedman, William

    2014-02-01

    Joseph Conrad was a notoriously tormented writer for whom the creative act was often a punishment severe enough to drive him into paralyzing depressions that delayed the completion of his novels, sometimes for years. By far the most agonizing of these projects was The Rescue, a novel he began in 1898, abandoned a year later, tried unsuccessfully to continue several times over the next two decades, but was only able to resume in 1918 and to complete, after another tortured two-year struggle, in 1920. An explanation for this incapacity, that is powerfully suggested by the novel's evocative title and perhaps unintentionally ironic subtitle (A Romance of the Shallows) has not yet been explored. Using Freud's 1910 essay on the rescue fantasy, "Contributions to the Psychology of Love: A Special Type of Choice of Object Made by Men," and Emanuel Berman's instructive revision and expansion of the concept in his 2003 American Imago essay, "Ferenczi, Rescue, and Utopia," I argue that a substantial explanation for Conrad's tormented history with The Rescue is ascribable to its quite remarkably faithful treatment of a rescue fantasy with deep and disabling resonance for its author. More specifically, the difficulty was compounded by the novel's dramatization of the soul-crushing conflict between two such fantasies: one in the service of the masculine ideal of unflinching dedication to a heroic purpose, the other promising satisfaction to the equally potent demands of emotional and sexual desire. Features of Conrad's narrative fit so tightly and consistently with the theory as Freud (and Abraham) proposed and as Berman elaborated it that The Rescue offers itself as one of those rare and reinforcing instances wherein the literary text seems to validate the psychoanalytic theory at least as persuasively as the theory "understands" the text.

  11. The Conrad Observatory Research Facility

    NASA Astrophysics Data System (ADS)

    Lenhardt, W.; Melichar, P.

    2009-04-01

    The Conrad Observatory in Austria belongs to the group of most modern geophysical observatories worldwide. The observatory is situated 55 km SW of Vienna in the Eastern Alps. Since 2002 - when the observatory was officially opened - several research tasks, projects, training courses and workshops were carried out at this venue. The site is also magnetically very quiet - one of the requirements for establishing the second part of the observatory, which will serve as the magnetic base observatory for Austria in the future. So far, a tunnel of 145 m length equipped with seismometers, 3 boreholes of 100 m depth and one borehole of 50 m depth, as well as a laboratory, where the gravity is continuously moni-tored, are in operation. In addition an outside station has been built according to Austrian standards for reasons of comparison. Refraction profiles and borehole seismic was used to describe the subsurface conditions for H/V measurements and other scientific tasks. The underground observatory provides ex-cellent conditions to test seismometers under controlled conditions, and a newly developed calibration table assists in the determination of the generator constants of seismometers. Internet connection is available together with a re-distributed GPS-timing signal in the observatory. The NERIES Transnational Access activity TA-5 has attracted already project teams from Germany, Slovenia and The Netherlands to conduct specific instrument tests and comparisons between sensors. See also www.zamg.ac.at/conrad_observatory.

  12. Astronaut Charles Conrad using the bicycle ergometer

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Astronaut Charles Conrad Jr., Skylab 2 commander, during an exercise session on the bicycle ergometer in the crew quarters of the Skylab Orbital Workshop (OWS) in the Skylab 2 space station cluster in Earth orbit.

  13. GT-5 Recovery Conrad tweaks Coopers beard

    NASA Image and Video Library

    1965-08-29

    S65-46638 (29 Aug. 1965) --- Astronaut Charles Conrad Jr. tweaks astronaut L. Gordon Cooper's eight-day growth of beard for the cameramen while onboard the prime recovery vessel after their Gemini-5 flight.

  14. Astronaut Charles Conrad using the bicycle ergometer

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Astronaut Charles Conrad Jr., Skylab 2 commander, during an exercise session on the bicycle ergometer in the crew quarters of the Skylab Orbital Workshop (OWS) in the Skylab 2 space station cluster in Earth orbit.

  15. From films to thermoluminescence dosemeters: the Greek Atomic Energy Commission experience.

    PubMed

    Carinou, E; Drikos, G; Hourdakis, C; Hyvönen, H; Kamenopoulou, V

    2001-01-01

    The personnel dosimetry department of the Greek Atomic Energy Commission (GAEC) assures the individual monitoring of almost 8000 occupationally exposed workers. Thermoluminescence dosimetry systems will replace the existing photographic dosimetry system for the individual monitoring with the joint support of IAEA and GAEC. The thermoluminescence dosimetry system consists of two automated readers, one automated irradiator and about 20,000 dosemeters purchased from the Rados Co. The properties of two thermoluminescent materials have been compared: LiF has been chosen for the whole-body dosemeter configuration and Li2B4O7 for the extremities. The technical evaluation of the system has been performed according to the European and IEC standards. The overall uncertainty has been calculated. The existing database system, and the accounting and dispatching procedures have been adapted to the new demands. The system became operational on March 2000, and the official distribution of thermoluminescence dosemeters has begun.

  16. FIELD CORRECTION FACTORS FOR PERSONAL NEUTRON DOSEMETERS.

    PubMed

    Luszik-Bhadra, M

    2016-09-01

    A field-dependent correction factor can be obtained by comparing the readings of two albedo neutron dosemeters fixed in opposite directions on a polyethylene sphere to the H*(10) reading as determined with a thermal neutron detector in the centre of the same sphere. The work shows that the field calibration technique as used for albedo neutron dosemeters can be generalised for all kind of dosemeters, since H*(10) is a conservative estimate of the sum of the personal dose equivalents Hp(10) in two opposite directions. This result is drawn from reference values as determined by spectrometers within the EVIDOS project at workplace of nuclear installations in Europe. More accurate field-dependent correction factors can be achieved by the analysis of several personal dosimeters on a phantom, but reliable angular responses of these dosemeters need to be taken into account.

  17. Self-indicating radiation alert dosemeter (SIRAD).

    PubMed

    Riel, Gordon K; Winters, Patrick; Patel, Gordhan; Patel, Paresh

    2006-01-01

    In an event of a nuclear or dirty bomb explosion and a radiological accident, there is a need for self-indicating instant radiation dosemeter for monitoring radiation exposure. The self-indicating instant radiation alert dosemeter (SIRAD) is a credit card size radiation dosemeter for monitoring ionising radiation from a few hundredths of a Gray to a few Gray. It is always active and is ready to use. It needs no battery. The dosemeter develops colour instantly upon exposure, and the colour intensifies with dose. It has a colour chart so that the dose on the active element may be read by matching its colour with the chart that is printed next to it on the card. However, in this work, the dose is measured by the optical density of the element. The dosemeter cannot be reset. The response changes by <1% per degrees C from -20 to +60 degrees C. The shelf-life is >3 y at room temperature. It contains no hazardous materials. The dosemeter would meet the requirements of instantly monitoring high dose in an event of a nuclear or dirty bomb explosion or a radiation accident.

  18. SKYLAB 2 ASTRONAUT CONRAD PREPARES FOR CDDT

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Under watchful eyes of suit technician Joe Schmitt, Skylab 2 mission commander Charles Conrad, Jr., adjusts spacesuit glove before participating in the space vehicle Countdown Demonstration Test. He is scheduled to launched May 15, with astronauts Dr. Joseph P. Kerwin and Paul J. Weitz on a 28-day mission aboard the Skylab space station, slated for launch a day earlier.

  19. Language Acquisition and the Conrad Phenomenon.

    ERIC Educational Resources Information Center

    Lucas, Michael A.

    1998-01-01

    Three hypotheses of second-language learning (Interference Hypothesis, Input Hypothesis, Fundamental Difference Hypothesis) are applied to the case of Polish-born English novelist Joseph Conrad, to see how well they explain his language learning. The first two hypotheses fail to explain adequately his mastery of written English, whereas the last…

  20. The British Novel: Conrad to the Present.

    ERIC Educational Resources Information Center

    Wiley, Paul L.

    Intended for advanced undergraduate and graduate students who desire a useful research tool, this bibliography cites the works of and about British novelists, beginning with Joseph Conrad and terminating in 1950. The listings are selective with proper emphasis given to less celebrated but distinctive writers. A preface explaining the numerous…

  1. The British Novel: Conrad to the Present.

    ERIC Educational Resources Information Center

    Wiley, Paul L.

    Intended for advanced undergraduate and graduate students who desire a useful research tool, this bibliography cites the works of and about British novelists, beginning with Joseph Conrad and terminating in 1950. The listings are selective with proper emphasis given to less celebrated but distinctive writers. A preface explaining the numerous…

  2. Fast neutron dosemeter using pixelated detector Timepix.

    PubMed

    Bulanek, Boris; Ekendahl, Daniela; Prouza, Zdenek

    2014-10-01

    A Timepix detector covered with polyethylene convertors of different thicknesses is presented as a fast neutron real-time dosemeter. The application of different weighting factors in connection with the position of a signal in a Timepix detector enables one to obtain an energy-dependent signal equal to neutron dose equivalents. A simulation of a Timepix detector covered with polyethylene convertors using monoenergetic neutrons is presented. The experimental set-up of a dosemeter was also produced. The first results of detector response using different fast neutron sources are presented.

  3. Neutron dosimetry with TL albedo dosemeters at high energy accelerators.

    PubMed

    Haninger, T; Fehrenbacher, G

    2007-01-01

    The GSF-Personal Monitoring Service uses the TLD albedo dosemeter as standard neutron personal dosemeter. Due to its low sensitivity for fast neutrons however, it is generally not recommended for workplaces at high-energy accelerators. Test measurements with the albedo dosemeter were performed at the accelerator laboratories of GSI in Darmstadt and DESY in Hamburg to reconsider this hypothesis. It revealed that the albedo dosemeter can also be used as personal dosemeter at these workplaces, because at all measurement locations a significant part of neutrons with lower energies could be found, which were produced by scattering at walls or the ground.

  4. ASTRONAUT CONRAD, CHARLES - SKYLAB (SL)-2

    NASA Image and Video Library

    1973-05-09

    S73-25401 (8 May 1973) --- The members of the prime crew of the first manned Skylab mission go over a checklist during Skylab prelaunch training activity at Johnson Space Center. They are in the Apollo Command Module Mission Simulator in Bldg. 5 at JSC. They are, left to right, astronaut Charles Conrad Jr., commander; scientist-astronaut Joseph P. Kerwin, science pilot; and astronaut Paul J. Weitz, pilot. Photo credit: NASA

  5. ASTRONAUT CHARLE CONRAD - SKYLAB II (M-114)

    NASA Image and Video Library

    1973-06-05

    S73-27508 (6 June 1973) --- An artist's concept showing astronaut Charles Conrad Jr., Skylab 2 commander, attempting to free the solar array system wing on the Orbital Workshop during extravehicular activity at the Skylab 1 & 2 space station cluster in Earth orbit. The astronaut in the background is Joseph P. Kerwin, Skylab 2 science pilot. Here, Conrad is pushing up on the Beam Erection Tether (BET) to raise the stuck solar panel. The solar wing is only partially deployed; an aluminum strap is believed to be holding it down. Note the cut aluminum angle. Attach points for the BET are on the vent module of the solar array beam. The other end of the BET is attached to the "A" frame supporting the Apollo Telescope Mount (ATM) which is out of view. The aluminum strapping is to be out first, freeing the solar array beam. Then, if the beam does not automatically deploy, Conrad will attempt to help by pulling on the BET. The automatic openers may have become too cold to open without assistance. A deployed solar panel of the ATM is at upper left. The EVA is scheduled for Thursday, June 7th. This concept is by artist Paul Fjeld. Photo credit: NASA

  6. State of the Art in Electronic Dosemeters for Neutrons

    NASA Astrophysics Data System (ADS)

    Luszik-Bhadra, Marlies

    2011-05-01

    The paper presents an overview of electronic personal dosemeters for neutrons in mixed neutron/photon fields. The energy response of commercially available electronic dosemeters in quasi-monoenergetic neutron fields and their performance in working places is discussed. The response curves are extended to high-energy neutrons up to 100 MeV, new prototype dosemeters are described and discussed especially for use at high-energy accelerators and in space.

  7. Simulation and calibration of an active neutron dosemeter.

    PubMed

    Bergmeier, F; Volnhals, M; Wielunski, M; Rühm, W

    2014-10-01

    Here the latest development stages of the HMGU active neutron dosemeter are presented. This work includes the comparison of the dosemeter's response function, calculated with Geant4, and the measurements in monoenergetic neutron fields at the Physikalisch Technische Bundesanstalt in Braunschweig, Germany. These results were used to match the response function and the count-to-dose conversion factors of the dosemeter to the Hp(10) personal dose equivalent.

  8. Astronauts Weitz and Conrad suit up during prelaunch activity

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Astronaut Paul J. Weitz, prime crew pilot of the first manned Skylab mission, is suited up in bldg 5 at JSC during prelaunch training activity. He is assisted by Astronaut Charles Conrad Jr., prime crew commander. The man in the left background is wearing a face mask to insure that Conrad, Joseph Kerwin, and Weitz are not exposed to disease prior to launch.

  9. ASTRONAUT CHARLES CONRAD, JR. - TRAINING (PRIME CREW)(WATER EGRESS)

    NASA Image and Video Library

    1965-07-21

    Astronaut Charles Conrad Jr., Gemini 5 Pilot, sits in the Gemini Static Article 5 Spacecraft and prepares to be lowered from the deck of the NASA Motor Vessel Retriever for Water Egress Training. The rubber "hat" on Astronaut Conrad's head is a neck dam and pulls down and fits tightly around the collar of his suit to prevent water from entering the suit.

  10. ASTRONAUT CONRAD, CHARLES - SKYLAB (SL)-2

    NASA Image and Video Library

    1973-06-11

    S73-27730 (June 1973) --- The Skylab 2 crewmen, astronauts Charles Conrad Jr., Joseph P. Kerwin and Paul J. Weitz, move the S183 Ultraviolet Panorama astrophysics experiment equipment under zero-gravity conditions in space in the foreground compartment of the Orbital Workshop of the Skylab 1 & 2 space station in Earth orbit, as seen in this reproduction taken from a color television transmission made by a TV camera aboard the space station. The S183 equipment includes the S183 spectrograph, the S019 mirror assembly, and a Maurer camera. Photo credit: NASA

  11. ASTRONAUT CONRAD, CHARLES - SKYLAB (SL)-2

    NASA Image and Video Library

    1973-06-01

    S73-27260 (1 June 1973) --- Two of the three Skylab 2 crewmen demonstrate weightlessness in the forward compartment of the Orbital Workshop of the Skylab 1 & 2 space station cluster in Earth orbit, as seen in this reproduction taken from a color television transmission made by a TV camera aboard the space station. Scientist-astronaut Joseph P. Kerwin, science pilot, floats with his body extended. Kerwin is steadied by astronaut Charles Conrad Jr., commander. The crewmen performed exercises while floating. Photo credit: NASA

  12. ASTRONAUT CONRAD, CHARLES - SKYLAB (SL)-2

    NASA Image and Video Library

    1973-06-11

    S73-27729 (1 June 1973) --- Scientist-astronaut Joseph P. Kerwin, Skylab 2 science pilot, floats with his body outstretched as he demonstrates weightlessness in the forward compartment of the Orbital Workshop of the Skylab 1 & 2 space station cluster in Earth orbit, as seen in this reproduction taken from a color television transmission made by a TV camera aboard the space station. Astronaut Charles Conrad Jr., Skylab 2 commander, is visible on Kerwin's right. The Skylab 2 crewmen performed exercises while floating. Photo credit: NASA

  13. ASTRONAUT CHARLE CONRAD - SKYLAB II (TV)

    NASA Image and Video Library

    2006-05-27

    S73-26794 (26 May 1973) --- Two of the three Skylab 2 astronauts are seen in the wardroom of the crew quarters of the Orbital Workshop of the Skylab 1 space station cluster in Earth orbit in this reproduction taken from a color television transmission made by a TV camera aboard the space station. They are preparing a meal. Astronaut Charles Conrad Jr., commander, is in the right foreground. In the background is scientist-astronaut Joseph P. Kerwin, science pilot. Photo credit: NASA

  14. Operational experience of electronic active personal dosemeter and comparison with CaSo4:Dy TL dosemeter in Indian PHWR.

    PubMed

    Singh, Vishwanath P; Managanvi, S S; Bihari, R R; Bhat, H R

    2013-01-01

    Direct reading dosemeter has been used for day-to-day radiation exposure control and management for last four decades in Indian nuclear power plants (NPPs). Recently new real time, alarm and pre-alarm on equivalent dose/dose rate, storage of dose/dose rate and maximum dose rate, user-friendly electronic active personal dosemeter (APD) has been implemented into practice for the first time at Kaiga Atomic Power Station-3&4,  of Indian NPPs. The dosemeter showed tolerance level (L) 0.1085±0.0450 compared with 0.1869±0.0729 (average±SD) for CaSO4:Dy, TL dosemeter, having narrow range trumpet curve, nil electromagnetic interference. Records of >29 000 for APD and TL dosemeter were analysed for comparasion of the measurement of the individual dose. APD followed general acceptance rule of ±25 % for dose >1 mSv. Monthly Station collective dose by TL dosemeters and APD for normal reactor operation as well as outage are found in good agreement. Operational experiences and statistical analysis support that an APD dosemeter is reasonably equivalent to CaSO4:Dy TL dosemeter. The accuracy, reproducibility and repeatability of the measurement of radiation for (137)Cs are comparable with CaSO4:Dy, TL dosemeter. Operational experience of APD during the normal operation as well as outage showed as one of the best ALARA tool for occupational dose monitoring, control, management and future outage planning.

  15. Personal photon dosemeter trial--Devonport Royal Dockyard.

    PubMed

    Collison, Roger

    2005-03-01

    To establish an understanding of the operational responses of various personal dosemeters employed at Devonport and to assess new types of dosemeters, a photon dosemeter trial was conducted. Most day-to-day exposure is to relatively low dose rates. Therefore the suitability of each dosemeter for use within the relatively low Devonport dose rate environment has been assessed. The Panasonic TLD demonstrated a good representation of the dose within the medium to higher gamma energy ranges with an unexpected under-response at lower energies. The optically stimulated luminescent dosemeter showed a varied response within a degraded (60)Co environment. With consistent under-response, the NRPB TLD and film badge were found to generally be unsuitable for sites such as Devonport. The Harshaw TLD demonstrated a good representation of the dose. The RADOS RAD80 and QFD fail to meet current best industry standards. However, the QFD is the only direct reading dosemeter suitable for use where intrinsically safe equipment is required. The RADOS RAD52 and SAIC PD 2i show a reasonable representation of the dose received but should be adjusted to read within an operational (60)Co environment. Direct ion storage and Thermo [corrected] electronic personal dosemeters showed good representations of the dose. Inherent characteristics combined with the associated systems led to the conclusion that these dosemeters should be employed for preference.

  16. Astronaut Charles Conrad uses lunar equipment conveyer at Lunar Module

    NASA Image and Video Library

    1969-11-19

    Astronaut Charles Conrad Jr., commander, uses the lunar equipment conveyer (LEC) at the Lunar Module during the Apollo 12 extravehicular activity on the lunar surface. This photograph was taken by Astronaut Alan L. Bean, lunar module pilot.

  17. Astronaut Charles Conrad during extravehicular activity on lunar surface

    NASA Image and Video Library

    1969-11-20

    AS12-48-7149 (20 Nov. 1969) --- A close-up view of astronaut Charles Conrad Jr., commander of the Apollo 12 lunar landing mission, photographed during the extravehicular activity (EVA) on the surface of the moon. An EVA checklist is on Conrad's left wrist. A set of tongs, an Apollo Lunar Hand Tool (ALHT), is held in his right hand. Several footprints can be seen. Astronaut Richard F. Gordon Jr., command module pilot, remained with the Command and Service Modules (CSM) in lunar orbit while astronauts Conrad and Alan L. Bean, lunar module pilot, descended in the LM to explore the moon. Note lunar soil on the suit of Conrad, especially around the knees and below.

  18. Astronaut Conrad tweaks Astronaut Cooper's beard for the cameramen

    NASA Technical Reports Server (NTRS)

    1965-01-01

    Astronaut Charles Conrad Jr. tweaks Astronaut L. Gordon Cooper's eight-day growth of beard for the cameramen while onboard the prime recovery vessel after their Gemini 5 flight. The NASA Headquarter alternative photo number is 65-H-680.

  19. A neutron dosemeter for nuclear criticality accidents.

    PubMed

    d'Errico, F; Curzio, G; Ciolini, R; Del Gratta, A; Nath, R

    2004-01-01

    A neutron dosemeter which offers instant read-out has been developed for nuclear criticality accidents. The system is based on gels containing emulsions of superheated dichlorodifluoromethane droplets, which vaporise into bubbles upon neutron irradiation. The expansion of these bubbles displaces an equivalent volume of gel into a graduated pipette, providing an immediate measure of the dose. Instant read-out is achieved using an array of transmissive optical sensors which consist of coupled LED emitters and phototransistor receivers. When the gel displaced in the pipette crosses the sensing region of the photomicrosensors, it generates a signal collected on a computer through a dedicated acquisition board. The performance of the device was tested during the 2002 International Accident Dosimetry Intercomparison in Valduc, France. The dosemeter was able to follow the initial dose gradient of a simulated accident, providing accurate values of neutron kerma; however, the emulsion was rapidly depleted of all its drops. A model of the depletion effects was developed and it indicates that an adequate dynamic range of the dose response can be achieved by using emulsions of smaller droplets.

  20. Characteristics of dosemeter types for skin dose measurements in practice.

    PubMed

    Van Dam, J; Bosmans, H; Marchal, G; Wambersie, A

    2005-01-01

    A growing number of papers report deterministic effects in the skin of patients who have undergone interventional radiological procedures. Dose measurements, and especially skin dose measurements, are therefore increasingly important. Methods and acceptable dosemeters are, however, not clearly defined. This paper is the result of a literature overview with regard to assessing the entrance skin dose during radiological examinations by putting a dosemeter on the patient's skin. The relevant intrinsic characteristics, as well as some examples of clinical use of the different detector types, are presented. In this respect, thermoluminescence, scintillation, semiconductor and film dosemeters are discussed and compared with respect to their practical use.

  1. Establishing local workplace field correction factors for neutron personal dosemeters.

    PubMed

    Vanhavere, Filip; Cauwels, Vanessa

    2014-10-01

    The present personal neutron dosemeters still need local correction factors to be able to provide accuracy comparable with photon dosemeters. Characterisation of the local neutron field is an indispensable part of neutron dosimetry to obtain such correction factors. It is often overlooked that besides characterisation in the neutron energy also the directional distribution of neutrons plays a crucial part in this characterisation. The authors have done such characterisation in the energy and angle for four workplace fields in Paks NPP. For this a relatively simple approximation method was used using the Nprobe for the energy distribution and measurements on the six sides of the slab phantom with personal dosemeters for the directional distribution. This allowed one to estimate a reference neutron Hp(10) rate and to compare it with the response of several neutron personal dosemeters.

  2. Calibration of Far West Technology (FWT-60) radiachromic dye dosemeters

    SciTech Connect

    Mincher, B.J.; Zaidi, M.K.

    1992-08-01

    Radiachromic dye dosimetry was used to measure kilogray doses absorbed by various liquid samples during gamma-ray exposure in a spent nuclear fuel pool. The source of nuclear fuel was the Advanced Test Reactor (ATR) at the Idaho National Engineering Laboratory (INEL). Calibrations were performed using a {sup 60}Co source and were run on bare dosemeters, as well as on dosemeters which mocked to simulate the samples. These dosemeters were prepared as a dye-impregnated nylon film and are commercially available. When exposed to gamma-ray doses of 0.5 to 200 kGy, a color change occurs which has an optical density proportional to absorbed dose. The difference in the calibration curves demonstrated the importance of irradiation of dosemeters under conditions as close to the actual samples as possible. Since these dosemeters could not be immersed directly in the organic solutions of interest, they were sandwiched between layers of lucite and stainless steel. This simulated the conditions inside an irradiated sample and provides a practical method of measuring absorbed doses. The reproducibility of measurements using the radiachromic dye dosemeters is also shown. 10 refs.

  3. Calibration of Far West Technology (FWT-60) radiachromic dye dosemeters

    SciTech Connect

    Mincher, B.J.; Zaidi, M.K.

    1992-01-01

    Radiachromic dye dosimetry was used to measure kilogray doses absorbed by various liquid samples during gamma-ray exposure in a spent nuclear fuel pool. The source of nuclear fuel was the Advanced Test Reactor (ATR) at the Idaho National Engineering Laboratory (INEL). Calibrations were performed using a {sup 60}Co source and were run on bare dosemeters, as well as on dosemeters which mocked to simulate the samples. These dosemeters were prepared as a dye-impregnated nylon film and are commercially available. When exposed to gamma-ray doses of 0.5 to 200 kGy, a color change occurs which has an optical density proportional to absorbed dose. The difference in the calibration curves demonstrated the importance of irradiation of dosemeters under conditions as close to the actual samples as possible. Since these dosemeters could not be immersed directly in the organic solutions of interest, they were sandwiched between layers of lucite and stainless steel. This simulated the conditions inside an irradiated sample and provides a practical method of measuring absorbed doses. The reproducibility of measurements using the radiachromic dye dosemeters is also shown. 10 refs.

  4. Prediction analysis of dose equivalent responses of neutron dosemeters used at a MOX fuel facility.

    PubMed

    Tsujimura, N; Yoshida, T; Takada, C

    2011-07-01

    To predict how accurately neutron dosemeters can measure the neutron dose equivalent (rate) in MOX fuel fabrication facility work environments, the dose equivalent responses of neutron dosemeters were calculated by the spectral folding method. The dosemeters selected included two types of personal dosemeter, namely a thermoluminescent albedo neutron dosemeter and an electronic neutron dosemeter, three moderator-based neutron survey meters, and one special instrument called an H(p)(10) monitor. The calculations revealed the energy dependences of the responses expected within the entire range of neutron spectral variations observed in neutron fields at workplaces.

  5. Apollo 12 - Bean - Conrad - during geological field trip

    NASA Image and Video Library

    1969-10-24

    S69-55667 (10 Oct. 1969) --- Astronauts Charles Conrad Jr. and Alan L. Bean train for their upcoming Apollo 12 lunar landing mission. Here they are entering a simulated lunar surface area near Flagstaff, Arizona. Both are wearing lunar surface cameras strapped to their bodies. Conrad (left), the Apollo 12 mission commander, is carrying some of the tools from the geological tool container. The geological tool container, being carried here by Bean, the lunar module pilot, is similar to the one which will be used during scheduled extravehicular activity (EVA) periods on Nov. 19 and 20, 1969, on the lunar surface. While astronauts Conrad and Bean conduct their scheduled EVA on the moon's surface, astronaut Richard F. Gordon Jr., command module pilot, will man the Command and Service Modules (CSM) in lunar orbit.

  6. Astronaut Charles Conrad following exercise session on bicycle ergometer

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Astronaut Charles Conrad Jr., commander of the first manned Skylab mission, wipes perspiration from his face following an exercise session on the bicycle ergometer during Skylab training at JSC. Conrad is in the work and experiments compartment of the crew quarters of the Skylab Orbital Workshop (OWS) trainer at JSC. In addition to being the prime exercise for the crewmen, the ergometer is also used for the vector-cardiogram test and the metabolic activity experiment. The bicycle ergometer produces measured work loads for use in determining man's metabolic effectiveness.

  7. Covariance Generation Using CONRAD and SAMMY Computer Codes

    SciTech Connect

    Leal, Luiz C; Derrien, Herve; De Saint Jean, C; Noguere, G; Ruggieri, J M

    2009-01-01

    Covariance generation in the resolved resonance region can be generated using the computer codes CONRAD and SAMMY. These codes use formalisms derived from the R-matrix methodology together with the generalized least squares technique to obtain resonance parameter. In addition, resonance parameter covariance is also obtained. Results of covariance calculations for a simple case of the s-wave resonance parameters of 48Ti in the energy region 10-5 eV to 300 keV are compared. The retroactive approach included in CONRAD and SAMMY was used.

  8. Astronaut Charles Conrad checks out Human Vestibular Function experiment

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Astronaut Charles Conrad Jr., commander of the first manned Skylab mission, checks out the Human Vestibular Function, Experiment M131, during Skylab training at JSC. Conrad is in the work and experiments compartment of the crew quarters of the Skylab Orbital Workshop (OWS) trainer at JSC. The reference sphere with a magnetic rod is used by the astronaut to indicate body orientation non-visually. The litter chair in which he is seated can be rotated by a motor at its base or, when not being rotated, can tilt forward, backward or to either side.

  9. Potential clinical utility of a fibre optic-coupled dosemeter for dose measurements in diagnostic radiology.

    PubMed

    Jones, A Kyle; Hintenlang, David

    2008-01-01

    Many types of dosemeters have been investigated for absorbed dose measurements in diagnostic radiology, including ionisation chambers, metal-oxide semiconductor field-effect transistor dosemeters, thermoluminescent dosemeters, optically stimulated luminescence detectors, film and diodes. Each of the aforementioned dosemeters suffers from a critical limitation, either the need to interrogate, or read, the dosemeter to retrieve dose information or large size to achieve adequate sensitivity. This work presents an evaluation of a fibre optic-coupled dosemeter (FOCD) for use in diagnostic radiology dose measurement. This dosemeter is small, tissue-equivalent and capable of providing true real-time dose information. The FOCD has been evaluated for dose linearity, angular dependence, sensitivity and energy dependence at energies, beam qualities and beam quantities relevant to diagnostic radiology. The FOCD displayed excellent dose linearity and high sensitivity, while exhibiting minimal angular dependence of response. However, the dosemeter does exhibit positive energy dependence, and is subject to attenuation of response when bent.

  10. Tenth ORNL Personnel Dosimetry Intercomparison Study

    SciTech Connect

    Swaja, R.E.; Chou, T.L.; Sims, C.S.; Greene, R.T.

    1985-03-01

    The Tenth Personnel Dosimetry Intercomparison Study was conducted at the Oak Ridge National Laboratory during April 9-11, 1984. Dosemeter badges from 31 participating organizations were mounted on 40cm Lucite phantoms and exposed to a range of dose equivalents which could be encountered during routine personnel monitoring in mixed radiation fields. The Health Physics Research Reactor served as the only source of radiation for eight of the ten irradiations which included a low (approx. 0.50 mSv) and high (approx. 10.00 mSv) neutron dose equivalent run for each of four shield conditions. Two irradiations were also conducted for which concrete- and Lucite-shield reactor irradiations were gamma-enhanced using a /sup 137/Cs source. Results indicated that some participants had difficulty obtaining measurable indication of neutron and gamma exposures at dose equivalents less than about 0.50 mSv and 0.20 mSv, respectively. Albedo dosemeters provided the best overall accuracy and precision for the neutron measurements. Direct interaction TLD systems showed significant variation in accuracy with incident spectrum, and threshold neutron dosemeters (film and recoil track) underestimated reference values by more than 50%. Gamma dose equivalents estimated in the mixed fields were higher than reference values with TL gamma dosemeters generally yielding more accurate results than film. Under the conditions of this study in which participants had information concerning exposure conditions and radiation field characteristics prior to dosemeter evaluation, only slightly more than half of all reported results met regulatory standards for neutron and gamma accuracy. 19 refs., 2 figs., 29 tabs.

  11. Astronauts Conrad and Gordon demonstrate tethering procedures for news media

    NASA Technical Reports Server (NTRS)

    1966-01-01

    Astronauts Charles Conrad (left), command pilot, and Richard F. Gordon (right), pilot, demonstrate tether procedure between their Gemini 11 spacecraft and the Agena Target Docking Vehicle at the post flight press conference. They use models of their spacecraft and its Agena to illustrate maneuvers.

  12. Astronauts Conrad and Gordon demonstrate tethering procedures for news media

    NASA Technical Reports Server (NTRS)

    1966-01-01

    Astronauts Charles Conrad (center), command pilot, and Richard F. Gordon (right), pilot, demonstrate tether procedure between their Gemini 11 spacecraft and the Agena Target Docking Vehicle at the post flight press conference. They use models of their spacecraft and its Agena to illustrate maneuvers. At left is George Low, Deputy Director, Manned Spacecraft Center, Houston.

  13. The origins of Michael Conrad's research programs (1964-1979).

    PubMed

    Pattee, H H

    2002-01-01

    This paper summarizes Michael Conrad's academic and professional career from the time he began his Ph.D. studies in 1964 to his appointment at Wayne State University in 1979. It describes the origins of several of his major research interests and presents a personal evaluation of how this early work continues to be of fundamental importance.

  14. Astronauts Conrad and Kerwin practice Human Vestibular Function experiment

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Astronaut Charles Conrad Jr., commander of the first manned Skylab mission, checks out the Human Vestibular Function, Experiment M131, during Skylab training at JSC. Scientist-Astronaut Joseph P. Kerwin, science pilot of the mission, goes over a checklist. The two men are in the work and experiments compartment of the crew quarters of the Skylab Orbital Workshop (OWS) trainer at JSC.

  15. Astronauts Conrad and Kerwin practice Human Vestibular Function experiment

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Astronaut Charles Conrad Jr., commander of the first manned Skylab mission, checks out the Human Vestibular Function, Experiment M131, during Skylab training at JSC. Scientist-Astronaut Joseph P. Kerwin, science pilot of the mission, goes over a checklist. The two men are in the work and experiments compartment of the crew quarters of the Skylab Orbital Workshop (OWS) trainer at JSC.

  16. Astronaut Charles Conrad climbs from spacecraft after splashdown

    NASA Technical Reports Server (NTRS)

    1966-01-01

    Astronaut Charles Conrad Jr., command pilot of the Gemini 11 space mission, climbs from the spacecraft minutes after splashdown. Astronaut Richard F. Gordon Jr., pilot, still has his hatch closed. The U.S. Navy frogman team attached a flotation collar to the spacecraft.

  17. Determination of the full response function of personal neutron dosemeters.

    PubMed

    Reginatto, M; Luszik-Bhadra, M

    2007-01-01

    The response of neutron dosemeters may be determined directly from measurements, provided a sufficiently large number of measurements in monoenergetic neutron fields covering the entire energy range of interest is available. In practice this is not feasible due to the lack of monoenergetic neutron fields in the thermal and intermediate energy region (i.e. energies<24 keV). To deal with this difficulty, we have developed a method which can take into account additional information about the response of the dosemeter. Our analysis makes use of two types of data, measurements made using monoenergetic neutron beams and measurements made in neutron fields with broad energy distributions. The dosemeter responses are described using a parametrised model, based on a minimum of assumptions: that they should fit the data within experimental uncertainties, and that they should remain close to a simple interpolation of the monoenergetic and thermal neutron field data.

  18. Astronaut Joseph Kerwin takes blood sample from Astronaut Charles Conrad

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Scientist-Astronaut Joseph P. Kerwin (right), Skylab 2 science pilot and a doctor of medicine, takes a blood sample from Astronaut Charles Conrad Jr., Sylab 2 commander, as seen in this reproduction taken from a color television transmission made by a TV camera aboard the Skylab 1 and 2 space station cluster in Earth orbit. The blood sampling was part of the Skylab Hematology and Immunology Experiment M110 series.

  19. Astronaut Charles Conrad trims hair of Astronaut Paul Weitz

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Astronaut Charles Conrad Jr., Skylab 2 commander, trims the hair of Astronaut Paul J. Weitz, Skylab 2 pilot, during the 28-day Skylab 2 mission in Earth orbit. They are in the crew quarters wardroom of the Orbital Workshop of the Skylab 1 and 2 space station. Weitz is holding a vacuum hose in his right hand. This picture was taken by Scientist-Astronaut Joseph P. Kerwin, Skylab 2 science pilot.

  20. Astronaut Joseph Kerwin takes blood sample from Astronaut Charles Conrad

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Scientist-Astronaut Joseph P. Kerwin (right), Skylab 2 science pilot and a doctor of medicine, takes a blood sample from Astronaut Charles Conrad Jr., Sylab 2 commander, as seen in this reproduction taken from a color television transmission made by a TV camera aboard the Skylab 1 and 2 space station cluster in Earth orbit. The blood sampling was part of the Skylab Hematology and Immunology Experiment M110 series.

  1. Astronauts Conrad and Kerwin - Human Vestibular Function Experiment - JSC

    NASA Image and Video Library

    1973-01-01

    S73-20678 (1 March 1973) --- Astronaut Charles Conrad Jr., commander of the first manned Skylab mission, checks out the Human Vestibular Function, Experiment M131, during Skylab training at Johnson Space Center. Scientist-astronaut Joseph P. Kerwin, science pilot of the mission, goes over a checklist. The two men are in the work and experiments compartment of the crew quarters of the Skylab Orbital Workshop (OWS) trainer at JSC. Photo credit: NASA

  2. Klaus Conrad (1905-1961): delusional mood, psychosis, and beginning schizophrenia.

    PubMed

    Mishara, Aaron L

    2010-01-01

    Klaus Conrad's major contribution to the phenomenology of psychosis focused on the patient's experiences during the prodromal and early psychotic phases of schizophrenia. The literature in English concerning his work is sparse, in part because Conrad's work contains complex concepts that lose much in translation. This communication attempts to clarify Conrad's thought, especially as it pertains to the role of mood and delusions in beginning psychosis and its underlying neurobiology.

  3. Performance and approval procedures for active personal dosemeters.

    PubMed

    Ginjaume, M

    2011-03-01

    Active personal dosemeters (APDs) are well accepted as useful and reliable instruments for individual dosimetry measurements. The increasing concern about studying the behaviour of APDs in pulsed fields is illustrated through revision of the results of the most representative studies on the performance of APDs in the last 5 y. The deficiencies of APDs in pulsed fields are discussed together with proposals to overcome them. Although there are no legal constraints or technical limitations for recognising APDs for legal dosimetry in facilities with continuous radiation fields, APDs continue to be mainly used as operational dosemeters. The approval procedures applicable to APDs, especially the approach undertaken by Germany, are presented. Finally, some trends in the developments and use of APDs are summarised.

  4. Superheated emulsions as high-energy neutron dosemeters.

    PubMed

    Das, Mala; Sawamura, Teruko; Abe, Masashi; Kaneko, Junichi H; Homma, Akira; Fujita, Fumiyuki; Tsuda, Shuichi; Nishitani, Takeo

    2004-01-01

    Superheated emulsions being inexpensive, easy to fabricate, and having tissue equivalent composition make them as one of the popular neutron dosemeters. One more advantage is that they can be made insensitive to gamma rays by the choice of the sensitive liquid. It is observed that the response of commercially available bubble detector to neutron decreases above 20 MeV while its response is roughly flat in the 0.1-15 MeV region. This restricts its application as a dosemeter to high-energy neutrons. The response of bubble detector from Bubble Technology Industries, has been observed by using Pb-breeder for high-energy neutrons from different facilities in Japan. It is observed that 2-3 cm Pb-breeder is effective in increasing the response of the detector to the nominal value. Theoretical calculation using MCNPX code indicates an increase in neutrons in the energy range of 0.1-10 MeV with Pb-breeder. The present work indicates the possibility of using the bubble detector as a dosemeter to high-energy neutron using a Pb-breeder of proper thickness.

  5. Art Criticism: The Potential of Conrad Fiedler's Ideas for Art Education.

    ERIC Educational Resources Information Center

    Abrahamson, Roy E.

    This paper discusses the ideas of Conrad Fiedler, a 19th century German philosopher of art, concerning art criticism, or the judging of works of visual art. In addition to a brief biography of Conrad Fiedler, the paper's main subject is Fiedler's ideas on art criticism as expressed in his book "On Judging Works of Visual Art" (1876,…

  6. Skylab 2 Astronaut Charles Conrad Jr. suiting up at KSC during prelaunch.

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Astronaut Charles Conrad Jr., commander of the Skylab 2 mission, is suited up in the Manned Spacecraft Operations Building at the Kennedy Space Center during Skylab 2 pre-launch preparations. Skylab 2, with astronauts Conrad, Joseph P. Kerwin, and Paul J. Weitz aboard, was launched from KSC's Pad B, Launch Complex 39, at 9:00 a.m. (EDT), May 25, 1973.

  7. Joseph Conrad's Empathy for Exploited Africans in "The Heart of Darkness."

    ERIC Educational Resources Information Center

    Farley, Ena L.

    1990-01-01

    Seemingly contradictory positions of J. Conrad as both a racist and an opponent of race-based imperial practices are discussed with reference to "The Heart of Darkness." It is argued that Conrad made a conscious effort to shake off the racial theories of the time and to deplore imperial racism. (SLD)

  8. Astronaut Charles Conrad discusses x-rays with medical team at Cape Kennedy

    NASA Technical Reports Server (NTRS)

    1965-01-01

    Astronaut Charles Conrad Jr., (dark shirt), pilot for Gemini 5 space flight, discusses x-rays with members of the medical team at Cape Kennedy. Left to right are: Dr. Eugene Tubbs; Astronaut Conrad; Dr. Charles A. Berry, Chief, Center Medical Programs, Manned Spacecraft Center; and (seated) Dr. Robert Moser, Medical Monitor with the U.S. Army.

  9. Astronauts Alan Bean and Charles Conrad on Lunar Surface

    NASA Technical Reports Server (NTRS)

    1969-01-01

    The second manned lunar landing mission, Apollo 12 launched from launch pad 39-A at Kennedy Space Center in Florida on November 14, 1969 via a Saturn Five launch vehicle. The Saturn V vehicle was developed by the Marshall Space Flight Center (MSFC) under the direction of Dr. Wernher von Braun. Aboard Apollo 12 was a crew of three astronauts: Alan L. Bean, pilot of the Lunar Module (LM), Intrepid; Richard Gordon, pilot of the Command Module (CM), Yankee Clipper; and Spacecraft Commander Charles Conrad. The LM, Intrepid, landed astronauts Conrad and Bean on the lunar surface in what's known as the Ocean of Storms while astronaut Richard Gordon piloted the CM, Yankee Clipper, in a parking orbit around the Moon. Their lunar soil activities included the deployment of the Apollo Lunar Surface Experiments Package (ALSEP), finding the unmanned Surveyor 3 that landed on the Moon on April 19, 1967, and collecting 75 pounds (34 kilograms) of rock samples. In this photograph, one of the astronauts on the Moon's surface is holding a container of lunar soil. The other astronaut is seen reflected in his helmet. Apollo 12 safely returned to Earth on November 24, 1969.

  10. Astronauts Alan Bean and Charles Conrad on Lunar Surface

    NASA Technical Reports Server (NTRS)

    1969-01-01

    The second manned lunar landing mission, Apollo 12 launched from launch pad 39-A at Kennedy Space Center in Florida on November 14, 1969 via a Saturn Five launch vehicle. The Saturn V vehicle was developed by the Marshall Space Flight Center (MSFC) under the direction of Dr. Wernher von Braun. Aboard Apollo 12 was a crew of three astronauts: Alan L. Bean, pilot of the Lunar Module (LM), Intrepid; Richard Gordon, pilot of the Command Module (CM), Yankee Clipper; and Spacecraft Commander Charles Conrad. The LM, Intrepid, landed astronauts Conrad and Bean on the lunar surface in what's known as the Ocean of Storms while astronaut Richard Gordon piloted the CM, Yankee Clipper, in a parking orbit around the Moon. Their lunar soil activities included the deployment of the Apollo Lunar Surface Experiments Package (ALSEP), finding the unmanned Surveyor 3 that landed on the Moon on April 19, 1967, and collecting 75 pounds (34 kilograms) of rock samples. In this photograph, one of the astronauts on the Moon's surface is holding a container of lunar soil. The other astronaut is seen reflected in his helmet. Apollo 12 safely returned to Earth on November 24, 1969.

  11. A method for evaluating personal dosemeters in workplace with neutron fields.

    PubMed

    de Freitas Nascimento, Luana; Cauwels, Vanessa; Vanhavere, Filip

    2012-04-01

    Passive detectors, as albedo or track-etch, still dominate the field of neutron personal dosimetry, mainly due to their low-cost, high-reliability and elevated throughput. However, the recent appearance in the market of electronic personal dosemeters for neutrons presents a new option for personal dosimetry. In addition to passive detectors, electronic personal dosemeters necessitate correction factors, concerning their energy and angular response dependencies. This paper reports on the results of a method to evaluate personal dosemeters for workplace where neutrons are present. The approach here uses few instruments and does not necessitate a large mathematical workload. Qualitative information on the neutron energy spectrum is acquired using a simple spectrometer (Nprobe), reference values for H*(10) are derived from measurements with ambient detectors (Studsvik, Berthold and Harwell) and angular information is measured using personal dosemeters (electronic and bubbles dosemeters) disposed in different orientations on a slab phantom.

  12. Single-ion dosemeter based on floating gate memories.

    PubMed

    Cellere, G; Paccagnella, A; Visconti, A; Bonanomi, M; McNulty, P J

    2006-01-01

    Floating Gate (FG) nonvolatile memories are based on a tiny polysilicon layer (the FG) which can be permanently charged with electrons or holes, thus changing the threshold voltage of a MOSFET. Every time a FG is hit by a high energy ion, it experiences a charge loss, depending on the ion linear energy transfer (LET) and on the transistor geometrical and electrical characteristics. This paper discusses the opportunities to use this devices as single an ion dosemeter with sub-micrometer spatial resolution and capable of distinguish the impinging ion LET.

  13. Skylab beverage container filled with orange juice held by Astronaut Conrad

    NASA Technical Reports Server (NTRS)

    1973-01-01

    An accordian-style beverage dispenser filled with orange juice is held by Astronaut Charles Conrad Jr., Skylab 2 commander, in this close-up view which is a reproduction taken from a color television transmission made by a TV camera aboard the Skylab 1 and 2 space station cluster in Earth orbit. Conrad (head and face not in view) is seated at the wardroom table in the crew quarters of the Orbital Workshop. The dispenser contained beverage crystals, and Conrad has just added the prescribed amount of water to make the orange drink.

  14. Skylab beverage container filled with orange juice held by Astronaut Conrad

    NASA Image and Video Library

    1973-05-30

    S73-27078 (30 May 1973) --- An accordian-style beverage dispenser filled with orange juice is held by astronaut Charles Conrad Jr., Skylab 2 commander, in this close-up view which is a reproduction taken from a color television transmission made by a TV camera aboard the Skylab 1 & 2 space station cluster in Earth orbit. Conrad (head and face not in view) is seated at the wardroom table in the crew quarters of the Orbital Workshop. The dispenser contained beverage crystals, and Conrad has just added the prescribed amount of water to make the orange drink. Photo credit: NASA

  15. Skylab beverage container filled with orange juice held by Astronaut Conrad

    NASA Technical Reports Server (NTRS)

    1973-01-01

    An accordian-style beverage dispenser filled with orange juice is held by Astronaut Charles Conrad Jr., Skylab 2 commander, in this close-up view which is a reproduction taken from a color television transmission made by a TV camera aboard the Skylab 1 and 2 space station cluster in Earth orbit. Conrad (head and face not in view) is seated at the wardroom table in the crew quarters of the Orbital Workshop. The dispenser contained beverage crystals, and Conrad has just added the prescribed amount of water to make the orange drink.

  16. Advances in personnel neutron dosimetry: part 2

    SciTech Connect

    Vallario, E.; Faust, L.

    1983-08-01

    A continuation of the advances in personnel neutron dosimetry research programs and technology transfer reviews work on active dosimeters, electronic devices that determine the dose equivalent to a worker during an exposure to neutron radiation. Active dosemeters are routinely used for gamma radiation dosimetry. Experience with neutron-sensitive pocket rem-meters at several DOE laboratories covers three prototypes. Pocket rem-meters work well for detecting neutrons over a wide energy range. They give instantaneous readout of the accumulated neutron dose-equivalent. 1 figure.

  17. Recent Developments in the CONRAD Code regarding Experimental Corrections

    NASA Astrophysics Data System (ADS)

    Archier, P.; De Saint Jean, C.; Kopecky, S.; Litaize, O.; Noguère, G.; Schillebeeckx, P.; Volev, K.

    2013-03-01

    The CONRAD code is an object-oriented software tool developed at CEA Cadarache since 2005 to deal with problems arising during the evaluation process (data assimilation and analysis, physical modelling, propagation of uncertainties…). This paper will present recent developments concerning the experimental corrections, which are required when a neutron resonance shape analysis is performed. Several experimental aspects are detailed in this work: the possibility to use spectra in energy as well as in time, the implementation of both analytical (Chi-Square) and Monte-Carlo resolution functions, the sample homogeneity corrections using log-normal distributions. Each development aspect is illustrated with several examples and comparisons with other resonance analysis codes (SAMMY, REFIT).

  18. The CONRAD approach to biokinetic modeling of DTPA decorporation therapy.

    PubMed

    Breustedt, Bastian; Blanchardon, Eric; Bérard, Philippe; Fritsch, Paul; Giussani, Augusto; Lopez, Maria Antonia; Luciani, Andrea; Nosske, Dietmar; Piechowski, Jean; Schimmelpfeng, Jutta; Sérandour, Anne-Laure

    2010-10-01

    Diethylene Triamine Pentaacetic Acid (DTPA) is used for decorporation of plutonium because it is known to be able to enhance its urinary excretion for several days after treatment by forming stable Pu-DTPA complexes. The decorporation prevents accumulation in organs and results in a dosimetric benefit, which is difficult to quantify from bioassay data using existing models. The development of a biokinetic model describing the mechanisms of actinide decorporation by administration of DTPA was initiated as a task in the European COordinated Network on RAdiation Dosimetry (CONRAD). The systemic biokinetic model from Leggett et al. and the biokinetic model for DTPA compounds of International Commission on Radiological Protection Publication 53 were the starting points. A new model for biokinetics of administered DTPA based on physiological interpretation of 14C-labeled DTPA studies from literature was proposed by the group. Plutonium and DTPA biokinetics were modeled separately. The systems were connected by means of a second order kinetics process describing the chelation process of plutonium atoms and DTPA molecules to Pu-DTPA complexes. It was assumed that chelation only occurs in the blood and in systemic compartment ST0 (representing rapid turnover soft tissues), and that Pu-DTPA complexes and administered forms of DTPA share the same biokinetic behavior. First applications of the CONRAD approach showed that the enhancement of plutonium urinary excretion after administration of DTPA was strongly influenced by the chelation rate constant. Setting it to a high value resulted in a good fit to the observed data. However, the model was not yet satisfactory since the effects of repeated DTPA administration in a short time period cannot be predicted in a realistic way. In order to introduce more physiological knowledge into the model several questions still have to be answered. Further detailed studies of human contamination cases and experimental data will be needed in

  19. Detectors/Dosemeters of galactic and solar cosmic rays.

    PubMed

    Tommasino, L

    2004-01-01

    Different passive multidetector stacks have been developed at the Italian National Agency for Environmental Protection (ANPA-stack), which makes it possible to measure directly ionising radiations, low-energy and high-energy neutrons, and high-energy charged (HZE) particles. The stack consists of several types of passive devices, namely recoil-track and fission-track detectors, bubble detectors, thermoluminescence dosemeters and an electronic personal dosemeter. Most of these detectors have been used on earth for the assessment of the occupational exposure, or in outer space for cosmic ray physics and/or for the assessment of the dose received by astronauts. A great deal of efforts and new developments have been required to make these detectors useful for in-flight measurements. As outcome of these extensive efforts, different new detectors have been developed, which exploit some of the most successful principles of radiation detection, such as the use of avalanche processes to facilitate the registration of nuclear tracks and the use of coincidence-counting to increase the signal-to-noise ratio. On the basis of these new detectors, different systems (generally referred to as ANPA-stack) have been obtained, which have been successfully applied for a variety of different measurements of cosmic ray radiation fields and doses.

  20. Type testing of the Siemens Plessey electronic personal dosemeter.

    PubMed

    Hirning, C R; Yuen, P S

    1995-07-01

    This paper presents the results of a laboratory assessment of the performance of a new type of personal dosimeter, the Electronic Personal Dosemeter made by Siemens Plessey Controls Limited. Twenty pre-production dosimeters and a reader were purchased by Ontario Hydro for the assessment. Tests were performed on radiological performance, including reproducibility, accuracy, linearity, detection threshold, energy response, angular response, neutron response, and response time. There were also tests on the effects of a variety of environmental factors, such as temperature, humidity, pulsed magnetic and electric fields, low- and high-frequency electromagnetic fields, light exposure, drop impact, vibration, and splashing. Other characteristics that were tested were alarm volume, clip force, and battery life. The test results were compared with the relevant requirements of three standards: an Ontario Hydro standard for personal alarming dosimeters, an International Electrotechnical Commission draft standard for direct reading personal dose monitors, and an International Electrotechnical Commission standard for thermoluminescence dosimetry systems for personal monitoring. In general, the performance of the Electronic Personal Dosemeter was found to be quite acceptable: it met most of the relevant requirements of the three standards. However, the following deficiencies were found: slow response time; sensitivity to high-frequency electromagnetic fields; poor resistance to dropping; and an alarm that was not loud enough. In addition, the response of the electronic personal dosimeter to low-energy beta rays may be too low for some applications. Problems were experienced with the reliability of operation of the pre-production dosimeters used in these tests.

  1. Unit 5, STA. 53+25+RB, Conrad buildingcontext Johnstown Local Flood ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Unit 5, STA. 53+25+RB, Conrad building-context - Johnstown Local Flood Protection Project, Beginning on Conemaugh River approx 3.8 miles downstream from confluence of Little Conemaugh & Stony Creek Rivers at Johnstown, Johnstown, Cambria County, PA

  2. Unit 5, STA. 53+25+RB, Conrad buildingdetail Johnstown Local Flood ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Unit 5, STA. 53+25+RB, Conrad building-detail - Johnstown Local Flood Protection Project, Beginning on Conemaugh River approx 3.8 miles downstream from confluence of Little Conemaugh & Stony Creek Rivers at Johnstown, Johnstown, Cambria County, PA

  3. ASTRONAUT CONRAD, CHARLES (PETE), JR. - X-RAYS - MEDICAL TEAM MEMBERS - CAPE

    NASA Image and Video Library

    1965-08-17

    S65-28699 (17 Aug. 1965) --- Astronaut Charles Conrad Jr. (dark shirt), pilot for the Gemini-5 spaceflight, discusses x-rays with members of the medical team at Cape Kennedy. Left to right are Dr. Eugene Tubbs; astronaut Conrad; Dr. Charles A. Berry, chief, Center Medical Programs, Manned Spacecraft Center; and Dr. Robert Moser (seated), Medical Monitor with the U.S. Army.

  4. Astronaut Charles Conrad as test subject for Lower Body Negative Pressure

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Astronaut Charles Conrad Jr., Skylab 2 commander, serves as test subject for the Lower Body Negative Pressure (LBNP) (M092) Experiment, as seen in this reproduction taken from a color television transmission made by at TV camera aboard the Skylab 1 and 2 space station cluster in Earth orbit. Scientist-Astronaut Joseph P. Kerwin, Skylab 2 science pilot, assists Conrad into the LBNP device. Kerwin served as monitor for the experiment.

  5. RESPONSE OF DOSEMETERS IN FIELDS GENERATED BY LASER-ACCELERATED PROTONS.

    PubMed

    Olšovcová, V; Versaci, R; Ambrožová, I; Zelenka, Z; Kaufman, J; Margarone, D; Kim, I J; Jeong, T M

    2016-09-01

    In laser-driven acceleration, ultra-short and intense laser pulses are focussed on targets to generate beams of ionising radiation. One of the most important issues to be addressed is personal monitoring. While traditional dosemeters were designed primarily for measurements in continuous fields, dosemeters for laser laboratories must be capable of working in pulsed fields of pulse length below 1 ps, in a single-shot regime up to the repetition rate of 1 kHz. Responses of conventional dosemeters (films, polyallyldiglycol carbonate, electronic personal dosemeter) to proton bunches of up to 30 MeV energy produced by South Korean PW laser system at the Advanced Photonics Research Institute, Gwangju Institute of Science and Technology were studied, both by means of Monte Carlo simulations and experimentally. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. DOSIMETRIC PROPERTIES OF THE NEW TLD ALBEDO NEUTRON DOSEMETER AWST-TL-GD 04.

    PubMed

    Haninger, T; Henniger, J

    2016-09-01

    A new official albedo dosemeter based on thermoluminescent detectors has been introduced in 2015 by the individual monitoring service of the Helmholtz Zentrum München for monitoring persons who are exposed occupationally against photon and neutron radiation. To enhance the sensitivity for fast neutrons, a new badge with an enlarged albedo window has been developed at TU Dresden. The properties of the new albedo dosemeter are discussed, and the results of official intercomparisons and field calibrations are shown.

  7. Response of Harshaw neutron thermoluminescence dosemeters in terms of the revised ICRP/ICRU recommendations.

    PubMed

    Veinot, K G; Hertel, N E

    2005-01-01

    To monitor workers for external neutron radiation dose, the Y-12 National Security Complex utilises the thermoluminescence dosemeters (TLDs) manufactured by Harshaw. At Y-12, the majority of external dose to workers is due to low-energy photon and/or beta particles emitted from uranium and its progeny. However, some neutron dose is expected since neutrons are produced from (alpha,n) reactions in various compounds found at the plant, including UF4 and UF6. Neutron sources, such as 252Cf, are also used throughout the complex. The Harshaw neutron dosemeter consists of two gamma-sensitive elements (7Li) and two neutron-sensitive elements enriched in 6Li with various shielding/filter materials placed around each of them. In this work, the energy response of the dosemeter to neutrons has been calculated using the Monte Carlo transport code MCNP Version 4-C and, these results are compared with the measured response of the dosemeter to unmoderated and D2O-moderated 252Cf neutrons. The response of the dosemeter has also been determined in terms of the personal absorbed dose and personal dose equivalent as a function of neutron energy based on the recommendations of the ICRP Publication 60 and ICRU Report 49. The energy response of the dosemeter characteristics can be used to generate spectral conversion coefficients for routine neutron absorbed dose and dose equivalent calculations.

  8. Characterisation of PRESAGE: A new 3-D radiochromic solid polymer dosemeter for ionising radiation.

    PubMed

    Adamovics, J; Maryanski, M J

    2006-01-01

    For the past 50 years there has been interest in developing 3-D dosemeters for ionising radiation. Particular emphasis has been put on those dosemeters that change their optical properties in proportion to the absorbed dose. Many of the dosemeters that have been evaluated have had limitations such as lack of transparency, diffusion of the image of the dose distribution or poor stability of baseline optical density. Many of these performance limitations have been overcome by the development of PRESAGE, an optically clear polyurethane-based radiochromic 3-D dosemeter. The solid PRESAGE dosemeter is formulated with a free radical initiator and a leuco dye and it does not require a container to maintain its shape. The polyurethane matrix is tissue equivalent and prevents the diffusion of the dose distribution image. There is a linear dose-response, which is independent of both photon energy and dose rate. Simple precautions such as preventing long-term exposure to additional ionising radiation including ultraviolet and controlling storage temperatures prevent the bleaching of the radiochromic response field within the irradiated dosemeter.

  9. Quality assurance of personal beta particle dosemeters used for individual monitoring of occupationally exposed persons.

    PubMed

    Helmstädter, Klaus; Ambrosi, Peter

    2007-01-01

    As a result of investigations and intercomparison measurements organised from 1996 to 1999 by PTB, several types of personal dosemeters, all based on TLD, were selected by the dosimetry services for the measurement of the personal dose equivalent Hp(0.07) in beta and/or photon radiation fields. These dosemeters have now the status of legal personal beta partial-body dosemeters. Workplaces at which beta radiation might significantly contribute to the doses to the extremities are to be found today with increasing frequency in radiation therapy, radiation source production and nuclear power plants. Quality assurance for beta personal dosemeters is stipulated by guidelines for the official dosimetry service and is carried out by way of the intercomparison measurements organised periodically by the PTB. The results are evaluated based on the recommendations of the German Commission on Radiological Protection (SSK). The procedure of these intercomparison measurements will be explained in detail. The experience gained from three series of comparisons with seven types of fingerring dosemeters will be described and the results will be presented. The anonymity of the dosemeter types and of the participants in the intercomparison will be preserved.

  10. High-energy response of passive dosemeters in use at LANL.

    PubMed

    Olsher, Richard H; McLean, Thomas D; Mallett, Michael W; Romero, Leonard L; Devine, Robert T; Hoffman, Jeffrey M

    2007-01-01

    The high-energy neutron response of three passive dosemeters in use at the Los Alamos National Laboratory (LANL) has been investigated using metrology-grade fields. The dosemeters include the LANL Model 8823 TLD badge and the LANL PN3 track etch device. Both are dosemeters of record at LANL. The third device was the Personal Neutron Dosemeter (PND), a superheated emulsion device, manufactured by Bubble Technology Industries, Inc. (BTI). The response of the three dosemeters at neutron energies exceeding 10 MeV was assessed with monoenergetic neutrons at the Physikalisch-Technische Bundesanstalt facility (14.8 and 19 MeV). For the sake of completeness, data collected at lower energies are also included in this study. High-energy quasi-monoenergetic beams produced by the cyclotron facilities at the Université Catholique de Louvain (UCL) and the The Svedberg Laboratory (TSL) were also utilised as part of this study. These measurements were made to better understand and help interpret dosemeter readings obtained by workers at high-energy accelerators, such as the 800 MeV spallation neutron source facility located at the Los Alamos Neutron Science Center (LANSCE).

  11. Diamond dosimetry: Outcomes of the CANDIDO and CONRAD INFN projects

    NASA Astrophysics Data System (ADS)

    Bucciolini, M.; Borchi, E.; Bruzzi, M.; Casati, M.; Cirrone, P.; Cuttone, G.; De Angelis, C.; Lovik, I.; Onori, S.; Raffaele, L.; Sciortino, S.

    2005-10-01

    This paper reviews the main results of the study, carried out in the framework of the Italian National Institute of Nuclear Physics (INFN, Istituto Nazionale di Fisica Nucleare) projects, namely CANDIDO and CONRAD, on natural and synthetic diamond-based dosimeters for clinical radiotherapy. Characteristics of diamond such as radiation hardness, high sensitivity, tissue equivalence, etc., make this material interesting for dosimetry applications. For some years, natural diamonds have been commercially available for on-line radiotherapy dosimetry. Nevertheless, recent developments in the "Chemical Vapour Deposition" (CVD) technique have addressed the attention on synthetic samples that potentially could be grown at low cost and with features suitable for dosimetric use. Several samples, differently grown and with different electrical contacts, have been compared by measuring their current response during irradiation with high-energy photon, electron and proton beams. Properties of dosimetric interest such as linearity, pre-irradiation dose, dose rate dependence, stability and rise time have been investigated. The results obtained so far within the INFN collaboration demonstrate the suitability of natural diamond detectors for many radiotherapy applications and the great potential of CVD diamond-based devices even though, at present, the commercial natural diamond dosimeters have a better behaviour with respect to the synthetic samples. Further efforts have to be made mainly to improve the dynamic of response and performance stability.

  12. Coordination of research on internal dosimetry in Europe: the CONRAD project.

    PubMed

    Lopez, M A; Etherington, G; Castellani, C M; Franck, D; Hurtgen, C; Marsh, J W; Nosske, D; Doerfel, H; Andrasi, A; Bailey, M; Balashazy, I; Battisti, P; Bérard, P; Berkowski, V; Birchall, A; Blanchardon, E; Bonchuk, Y; de Carlan, L; Cantone, M C; Challeton-de Vathaire, C; Cruz-Suarez, R; Davis, K; Dorrian, D; Giussani, A; Le Guen, B; Hodgson, A; Jourdain, J R; Koukouliou, V; Luciani, A; Malatova, I; Molokanov, A; Moraleda, M; Muikku, M; Oeh, U; Puncher, M; Rahola, T; Ratia, H; Stradling, N

    2007-01-01

    The EUropean RAdiation DOSimetry Group (EURADOS) initiated in 2005 the CONRAD Project, a Coordinated Network for Radiation Dosimetry funded by the European Commission (EC), within the 6th Framework Programme (FP). The main purpose of CONRAD is to generate a European Network in the field of Radiation Dosimetry and to promote both research activities and dissemination of knowledge. The objective of CONRAD Work Package 5 (WP5) is the coordination of research on assessment and evaluation of internal exposures. Nineteen institutes from 14 countries participate in this action. Some of the activities to be developed are continuations of former European projects supported by the EC in the 5th FP (OMINEX and IDEAS). Other tasks are linked with ICRP activities, and there are new actions never considered before. A collaboration is established with CONRAD Work Package 4, dealing with Computational Dosimetry, to organise an intercomparison on Monte Carlo modelling for in vivo measurements of (241)Am deposited in a knee phantom. Preliminary results associated with CONRAD WP5 tasks are presented here.

  13. Personnel Preparation.

    ERIC Educational Resources Information Center

    Career Development for Exceptional Individuals, 1982

    1982-01-01

    The section on personnel preparation contains two articles--"Teachers-in-Training Conduct Field Trips for Special Class Students" by S. Squires and "A State-Wide, Inservice Project for Special Needs Personnel" by G. Markel and others. (SB)

  14. [Wilhelm Conrad Röntgen 1845-1923].

    PubMed

    Langfeldt, B

    1995-01-01

    Wilhelm Conrad Röntgen was born on March 27th 1845 in the small town of Lennep on the lower Rhine. In the year of the revolution 1848 the family moved to Apeldoorn in Holland to be with his mother's family. Here he started school at the Martinus van Doorn's private Institute. In December 1862 he commenced his studies at the Utrecht Technical School, but was expelled for doubtful reasons. As he had no School Leaving Certificate he attended closed lectures in philosophy at the University of Utrecht, and in 1865 he passed the entrance exam to the Polytechnicum in Zürich - despite the lack of a School Leaving Certificate - where the famous August Kundt taught him physics. Röntgen went with Kundt to Würzburg and in 1872 to Strasbourg. In 1875 Röntgen became professor in physics in Hohenheim in 1879 in Giessen and in 1888 he was appointed professor in physics in Würzburg. It was here that Röntgen experimented with the Crookes airfree tube and on the afternoon of November 8th 1895 he by chance saw some crystals of bariumplatincyanid shine behind a screen. He took pictures of his weights in their wooden box and later the first "medical" picture of his wife Bertha's hand. ... Röntgen was the first to be awarded the Nobel Prize in 1901. Röntgen died of cancer coli on February 7th, 1923. The world famous Berlin surgeon Ferdinand Sauerbruch was called to see him but too late to help. ...

  15. Deep fellowship: homosexuality and male bonding in the life and fiction of Joseph Conrad.

    PubMed

    Hodges, R R

    1979-01-01

    Conrad's biography reveals only peripheral, though suggestive, awareness of homosexuality. His fiction, however, shows a continuing concern with some underlying features of female and male homosexuality. Suggestions of a positive view of homoerotic relations can be discerned in the strong works of his early career, specifically Lord Jim and "The Secret Sharer." The later novels and stories, usually characterized as sentimental and conventional, dramatize an overt fear of homosexuality consistent with Conrad's hostile reaction to the Casement revelations. Chance features an evil lesbian, Victory an equally destructive homosexual male. Only the autobiographical A Shadow Line shows a return to the earlier positive attitude toward male bonding with sexual overtones. Scholars have been reluctant to notice these concerns, since Conrad is considered a "man's" writer.

  16. Characterization of optically stimulated luminescence dosemeters to measure organ doses in diagnostic radiology

    PubMed Central

    Endo, A; Katoh, T; Kobayashi, I; Joshi, R; Sur, J; Okano, T

    2012-01-01

    Objective The aim of this study was to assess the characteristics of an optically stimulated luminescence dosemeter (OSLD) for use in diagnostic radiology and to apply the OSLD in measuring the organ doses by panoramic radiography. Methods The dose linearity, energy dependency and angular dependency of aluminium oxide-based OSLDs were examined using an X-ray generator to simulate various exposure settings in diagnostic radiology. The organ doses were then measured by inserting the dosemeters into an anthropomorphic phantom while using three panoramic machines. Results The dosemeters demonstrated consistent dose linearity (coefficient of variation<1.5%) and no significant energy dependency (coefficient of variation<1.5%) under the applied exposure conditions. They also exhibited negligible angular dependency (≤10%). The organ doses of the X-ray as a result of panoramic imaging by three machines were calculated using the dosemeters. Conclusion OSLDs can be utilized to measure the organ doses in diagnostic radiology. The availability of these dosemeters in strip form proves to be reliably advantageous. PMID:22116136

  17. The first operational dosemeter for neutrons which complies with IEC standard 1323.

    PubMed

    Lahaye, T; Cutarella, D; Ménard, S; Bolognese-Milsztajn, T

    2001-01-01

    Individual neutron dosimetry represents one of the current difficulties in the field of radiological protection of workers. Since March 1999, the regulatory requirements in France for active (i.e. operational) dosimetry have been those of ICRP Publication 60, applicable from May 2000, necessitating the introduction of a new generation of neutron dosemeters. Over the last few years, the Institute for Nuclear Safety and Protection has been studying an individual electronic dosemeter for neutrons based on a semiconducting detector, capable of meeting the specifications laid down by a neutron dosimetry work group, including members from all the main players in the French nuclear industry. In 1998, the IPSN began transferring technology to the Saphymo company which, by the end of 2001, will be marketing Saphydose-n, the first individual dosemeter for neutrons which complies with IEC Standard 1323. This dosemeter is of compact design and can assess the individual dose equivalent Hp(10) in mixed neutron and gamma radiation fields. It wil be usable in any nuclear facility without prior knowledge of the average neutron spectrum or of the neutron-gamma ratio. It will be possible to connect the Saphydose-n dosemeter to any of the existing gamma deserter terminals to read the dose data and recharge the batteries.

  18. Numerical and experimental results of the operational neutron dosemeter 'Saphydose-N'.

    PubMed

    Lahaye, T; Chau, Q; Ménard, S; Ndontchueng-Moyo, M; Bolognese-Milsztajn, T; Rannou, A

    2004-01-01

    Since 1993, the Institute for Radiological Protection and Nuclear Safety (IRSN) has lead, in association with Electricité de France (EDF), a R&D study of a neutron personal electronic dosemeter. This dosemeter, called 'Saphydose-N', is manufactured by the SAPHYMO company. This paper presents first the optimisation of some detector components using Monte Carlo calculations, and second the test of the manufactured Saphydose-N under radiation following the IEC 1323 standard's recommendations for active personal neutron dosemeters. The measurements with the manufactured dosemeter were performed on the one hand at PTB (Physikalisch-Technische Bundesanstalt) in mono-energetic neutron fields and, on the other hand at IRSN in neutron fields generated by a thermal facility (SIGMA), radionuclide ISO sources and a realistic spectrum (CANEL/T400). The manufactured dosemeter Saphydose-N was also tested during measurement campaigns of the European programme EVIDOS ('Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields') at different nuclear workplaces. The study showed that Saphydose-N complies with the recommendations of standard IEC 1323 and can be used at any workplace with no previous knowledge of the neutron field characteristics.

  19. Characterization of optically stimulated luminescence dosemeters to measure organ doses in diagnostic radiology.

    PubMed

    Endo, A; Katoh, T; Kobayashi, I; Joshi, R; Sur, J; Okano, T

    2012-03-01

    The aim of this study was to assess the characteristics of an optically stimulated luminescence dosemeter (OSLD) for use in diagnostic radiology and to apply the OSLD in measuring the organ doses by panoramic radiography. The dose linearity, energy dependency and angular dependency of aluminium oxide-based OSLDs were examined using an X-ray generator to simulate various exposure settings in diagnostic radiology. The organ doses were then measured by inserting the dosemeters into an anthropomorphic phantom while using three panoramic machines. The dosemeters demonstrated consistent dose linearity (coefficient of variation<1.5%) and no significant energy dependency (coefficient of variation<1.5%) under the applied exposure conditions. They also exhibited negligible angular dependency (≤ 10%). The organ doses of the X-ray as a result of panoramic imaging by three machines were calculated using the dosemeters. OSLDs can be utilized to measure the organ doses in diagnostic radiology. The availability of these dosemeters in strip form proves to be reliably advantageous.

  20. A THIN-LAYER LIF THERMOLUMINESCENCE DOSEMETER SYSTEM WITH FAST READOUT FOR THE USE IN PERSONAL DOSIMETRY SERVICES.

    PubMed

    Walbersloh, J; Busch, F

    2016-09-01

    A newly developed thermoluminescence dosemeter system is presented that is suitable for application in fields where personal monitoring of a large number of users is required. The system presented here is intended to be used as the upcoming main dosemeter for whole body dosimetry at the dosimetry service of the MPA NRW (Germany) with ∼110,000 evaluations per month.

  1. Elimination of Cerenkov interference in a fibre-optic-coupled radiation dosemeter.

    PubMed

    Justus, Brian L; Falkenstein, Paul; Huston, Alan L; Plazas, Maria C; Ning, Holly; Miller, Robert W

    2006-01-01

    An optical fibre point dosemeter based on the gated detection of the luminescence from a Cu(1+)-doped fused quartz detector effectively eliminated errors due to Cerenkov radiation and native fibre fluorescence. The gated optical fibre dosemeter overcomes serious problems faced by scintillation and optically stimulated luminescence approaches to optical fibre point dosimetry. The dosemeter was tested using an external beam radiotherapy machine that provided pulses of 6 MV X rays. Gated detection was used to discriminate the signal collected during the radiation pulses, which included contributions from Cerenkov radiation and native fibre fluorescence, from the signal collected between the radiation pulses, which contained only the long-lived luminescence from the Cu(1+)-doped fused quartz detector. Gated detection of the luminescence provided accurate, real-time dose measurements that were linear with absorbed dose, independent of dose rate and that were accurate for all field sizes studied.

  2. Response of radiation protection dosemeters in mixed high-energy photon and electron radiation fields.

    PubMed

    Büermann, L; Gargioni, E; Kramer, H M

    2001-01-01

    The response of radiation protection dosemeters in terms of the phantom-related operational quantities Hp(10) and H'(10.0 degrees) was measured for personal and area monitoring systems in mixed high-energy electron and photon radiation fields with energies up to 7 MeV. Using mixed radiation fields composed of different fractions of charged particle and photon fluence, three conditions were produced at the point of measurement: charged particle equilibrium (CPE) (a), a lack (b) and an excess (c) of charged particles relative to the conditions of CPE. Personal and area dosemeters of different types were investigated under conditions (a)-(c). A large variability of the response of the different dosemeter types was observed. The results are presented and discussed.

  3. Dosemeter readings and effective dose to the cardiologist with protective clothing in a simulated interventional procedure.

    PubMed

    Schultz, F W; Zoetelief, J

    2008-01-01

    A personal dosemeter issued for individual monitoring is calibrated in terms of personal dose equivalent, usually H(P)(10). In general it yields a reasonable estimate of effective dose (E) when the exposed person does not wear protective clothing. In interventional cardiology, however, a lead equivalent apron is worn and often a thyroid collar. A correction factor will then be necessary to convert a dosemeter reading to E. To explore this factor an interventional cardiology procedure is simulated based on exposure conditions typical for a modern hospital in the BENELUX area. The dose to the cardiologist is investigated using Monte Carlo simulation of radiation transport. It is concluded that a personal dosemeter may best be worn outside the apron at a central position high on the chest for least dependence on the beam direction. It will overestimate E by roughly a factor of 20 (apron and thyroid collar of 0.25 mm Pb).

  4. Independent evaluation of optically stimulated luminescence (OSL) 'dot' dosemeters for environmental monitoring.

    PubMed

    Timilsina, Bindu; Gesell, Thomas F

    2011-01-01

    Optically stimulated luminescence (OSL) 'dot' dosemeters (manufactured by Landauer®) are reported to have a high degree of environmental stability, high level of sensitivity and provide wide range of dose measuring capabilities from 0.05 mGy to 100 Gy. The optical read out method is fast and relatively simple and permits repeated read out, but few studies have been performed about its application in monitoring radiation in the environment. This study was initiated to independently test the performance of OSL dot dosemeters for the application of measuring doses of radiation in the outdoor environment. Testing was performed in the laboratory to evaluate reproducibility and stability and in the field to evaluate accuracy relative to calibrated high-pressure ionisation chambers. The results showed that OSL dot dosemeters had good reproducibility and stability in both laboratory and field tests and met the performance requirements of standards of the American National Standards Institute.

  5. Use of composites of topaz-glass as TSEE and TL dosemeters.

    PubMed

    de Magalhães, C M S; Souza, D N; Caldas, L V E

    2006-01-01

    The properties of the thermally stimulated exoelectron emission (TSEE) and thermoluminescent (TL) emission of topaz-glass composites were studied with the aim of using them as solid-state dosemeters. The TSEE response was studied as a function of radiation energy and as a function of absorbed dose. Topaz-glass composites presented a linear TL and TSEE response to dose within a range of 0.01-1 Gy. The topaz-glass composites presented higher TSEE peaks than topaz-Teflon pellets. In the dosimetry of radiotherapic fields normally the responses of the topaz-glass dosemeters are comparable to topaz-Teflon pellets. The results confirmed that these new dosemeters can be useful in monitoring the quality of the radiation sources. This dose mapping technique is particularly useful in investigating dose distribution throughout a planned target volume.

  6. Operational comparison of TLD albedo dosemeters and solid state nuclear tracks detectors in fuel fabrication facilities.

    PubMed

    Tsujimura, N; Takada, C; Yoshida, T; Momose, T

    2007-01-01

    The authors carried out an operational study that compared the use of TLD albedo dosemeters and solid state nuclear tracks detector in plutonium environments of Japan Nuclear Cycle Development Institute, Tokai Works. A selected group of workers engaged in the fabrication process of MOX (Plutonium-Uranium mixed oxide) fuel wore both TLD albedo dosemeters and solid state nuclear tracks detectors. The TL readings were generally proportional to the counted etch-pits, and thus the dose equivalent results obtained from TLD albedo dosemeter agreed with those from solid state nuclear tracks detector within a factor of 1.5. This result indicates that, in the workplaces of the MOX fuel plants, the neutron spectrum remained almost constant in terms of time and space, and the appropriate range of field-specific correction with spectrum variations was small in albedo dosimetry.

  7. Gemini 11 Commander Conrad and Pilot Gordon at post flight press conference

    NASA Technical Reports Server (NTRS)

    1966-01-01

    Gemini 11 Commander Charles Conrad, Jr (left) and Pilot Richard F. Gordon, Jr describe mission activities during their post flight press conference at JSC. Gordon at the microphone talks about the extravehicular activity (EVA) photo projected behind the two crewmembers. During the EVA Gordon attached a tether to the Agena and retrieved a nuclear emulsion experiment package.

  8. The significance of depersonalization in the life and writings of Joseph Conrad.

    PubMed

    Hamilton, J W

    1975-01-01

    Through reference to his letters and fiction, this paper attempts to demonstrate how Conrad made use of depersonalization in order to cope with the childhood loss of his parents and to avoid, whenever possible, psychotic regression. Genetic and dynamic aspects of depersonalization are noted along with the relationship between dream and depersonalization.

  9. Astronaut Charles Conrad - Cockpit - Lunar Landing Training Vehicle - Ellington AFB (EAFB), TX

    NASA Image and Video Library

    1969-10-29

    S69-56058 (25 Oct. 1969) --- Astronaut Charles Conrad Jr., commander of the Apollo 12 lunar landing mission, sits in the cockpit of a Lunar Landing Training Vehicle (LLTV) during a lunar simulation flight at Ellington Air Force Base. The LLTV is used to train Apollo crews in lunar landing techniques.

  10. [Cosmus Conrad Cuno (1652-1745) on a human ectoparasite: the head louse].

    PubMed

    Müller, G H

    1979-07-01

    Cosmus Conrad Cuno, a less well known optician and inventor of microscopes from the second half of the 17th century, published in 1734 at Augsburg his Observationes durch dessen verfertigte Microscopia where along with various observations he communicated salient details pertaining to the biology of the head louse.

  11. Official dosimetry with personal electronic dosemeters--the framework in Germany.

    PubMed

    Czarwinski, R; Kaulard, J; Pfeffer, W

    2007-01-01

    In Germany, personal electronic dosemeters (AEPDs) are presently applied mainly for operational radiation protection monitoring particularly in nuclear power engineering companies, large hospitals and research centres. This is done in addition to the official dosimetry of record. Therefore, frequently, double monitoring occurs-officially and operationally. A crucial advantage of AEPDs compared with passive dosemeters is the ability to adapt the monitoring period to the working time in controlled areas and to allow an immediate readout of the dose after leaving the controlled area, e.g. a job-related monitoring is possible by correlating the readout dose with the job performed. Germany started a general research project, consisting of two parts, for an optimised implementation of personal electronic dosemeters into official dosimetry. The use of AEPDs as official dosemeters depends on an approval by Federal and Federal State ('Länder') authorities as an official dosimetry system, which has to comply with special requirements ensuring that the legal requirements are fulfilled. The formulation of these special requirements is in the focus of part one of the research project, supervised by the Federal Office for Radiation Protection (BfS) and performed by the Gesellschaft für Anlagen- und Reaktorsicherheit (GRS) mbH. As a result of part one, a framework was developed which is the basis for a future technical implementation project. Part one is described in the paper, while part two is still to be initiated and will deal with the implementation and testing phase of the introduction of personal electronic dosemeters as official dosemeters.

  12. Comparison of measurements on tissue kerma and photon radiation dose made with emergency dosemeters

    SciTech Connect

    Golub, V.V.; Lashuk, A.I.; Shalin, V.A.

    1987-05-01

    The purpose of this paper is to compare the tissue equivalence and tissue kerma for dosimetric tissue-equivalent detectors with allowance for the neutron spectra. Results are given for the calculated dose sensitivities for the DINA and GNEIS dosemeters for a portion of the neutron spectra recommended by IAEA for comparative tests. The measurements were made with five nuclear systems - BR-10, RF-GS, BR-1-21, BR-1-21, and IBR-30 - as well as with accelerators. Doses from photon radiation were also measured using thermoluminescent and photoluminescent dosemeters sensitive to neutrons.

  13. Study of Residual TL of CaSO4:Dy-based Thermoluminescence Dosemeter.

    PubMed

    Sahai, Manish K; Pradhan, S M; Bakshi, A K; Datta, D

    2017-04-27

    Thermoluminescence (TL) signal obtained during second readout of a TL dosemeter disc previously exposed to ionising radiation is termed as residual TL. The origin of residual TL has not been discussed in detail so far in the literature. In this work, experimentally obtained residual TL signal and its origin is studied for CaSO4:Dy-based TL dosemeter through numerical simulation and role of deeper traps has been discussed. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. A comparison of the response of PADC neutron dosemeters in high-energy neutron fields.

    PubMed

    Trompier, F; Boschung, M; Buffler, A; Domingo, C; Cale, E; Chevallier, M-A; Esposito, A; Ferrarini, M; Geduld, D R; Hager, L; Hohmann, E; Mayer, S; Musso, A; Romero-Esposito, M; Röttger, S; Smit, F D; Sashala Naik, A; Tanner, R; Wissmann, F; Caresana, M

    2014-10-01

    Within the framework of the EURADOS Working Group 11, a comparison of passive neutron dosemeters in high-energy neutron fields was organised in 2011. The aim of the exercise was to evaluate the response of poly-allyl-glycol-carbonate neutron dosemeters from various European dosimetry laboratories to high-energy neutron fields. Irradiations were performed at the iThemba LABS facility in South Africa with neutrons having energies up to 66 and 100 MeV. © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Three-dimensional structure of Conrad and Moho discontinuities in Egypt

    NASA Astrophysics Data System (ADS)

    Abdelwahed, Mohamed F.; El-Khrepy, Sami; Qaddah, Atef

    2013-09-01

    The three-dimensional structures of Conrad and Moho discontinuities beneath Egypt are investigated by local earthquake travel time inversion. A number of 2513 events with 24,696 arrival time data recorded by the Egyptian National Seismic Network (ENSN) are used. The station corrections of P- and S-waves and the hypocentral parameters are simultaneously estimated with the Conrad and Moho depths. The results of this study show that the discontinuities form patterns of shallow and deep structures getting shallow toward the northern and eastern coast, and deeper toward western Desert and northeastern Sinai. The Conrad and Moho discontinuities are located within the depth range 9-17 km and 27-41 km, respectively. The depth ranges of Conrad and Moho discontinuities are respectively: 15-16 km and 31-33 km in greater Cairo and Dahshour; 15-18 km and 32-35 km in Sinai; 16-17 and 33-35 km along the Nile River; 9 and 30 km near the Red Sea coast; 15 and 39 km toward the western desert. The comprehensive comparison with previous crustal studies suggests that the main patterns of Moho undulations and the range of Moho depths are in good agreement with the previous crustal models in Egypt, as well as with the Bouguer gravity anomalies that well explain the Nile River sediments, Red Sea mountain belts and Western Desert depression and Oasis. The model of the Moho and Conrad discontinuities improves knowledge of the three dimensional structure of the crust beneath Egypt in wide areas where geophysical data is sparse.

  16. EURADOS trial performance test for personal dosemeters for external beta radiation.

    PubMed

    Christensen, P; Bordy, J M; Ambrosi, P; Bartlett, D T; Colgan, T; Hyvönen, H; Stadtmann, H

    2001-01-01

    On the initiative of the European Dosimetry Group (EURADOS) action group 'Harmonisation and Dosimetric Quality Assurance in Individual Monitoring for External Radiation' a trial performance test for whole-body and extremity personal dosemeters broadly representative of those in use in the EU was accomplished. This paper deals with the part of the performance test concerned with exposure to beta radiation. Fifteen dosimetric services participated with whole-body dosemeters intended to measure beta doses (Hp(0.07)) of which 13 used thermoluminescent (TL) detectors and two used photographic films. Eight services participated with extremity dosemeters which all used TL detectors. A description is given of the irradiation set-up, the characteristics of the irradiation fields, the calibration quantity applied and the performance criteria used for the evaluation of the results. The paper discusses in detail the results obtained from the exercise. In particular, based on the replies to a questionnaire issued to each participant, the results are analysed in relation to important design characteristics of the dosemeters taking part in the test.

  17. CORRECTIONS ASSOCIATED WITH ON-PHANTOM CALIBRATIONS OF NEUTRON PERSONAL DOSEMETERS.

    PubMed

    Hawkes, N P; Thomas, D J; Taylor, G C

    2016-09-01

    The response of neutron personal dosemeters as a function of neutron energy and angle of incidence is typically measured by mounting the dosemeters on a slab phantom and exposing them to neutrons from an accelerator-based or radionuclide source. The phantom is placed close to the source (75 cm) so that the effect of scattered neutrons is negligible. It is usual to mount several dosemeters on the phantom together. Because the source is close, the source distance and the neutron incidence angle vary significantly over the phantom face, and each dosemeter may receive a different dose equivalent. This is particularly important when the phantom is angled away from normal incidence. With accelerator-produced neutrons, the neutron energy and fluence vary with emission angle relative to the charged particle beam that produces the neutrons, contributing further to differences in dose equivalent, particularly when the phantom is located at other than the straight-ahead position (0° to the beam). Corrections for these effects are quantified and discussed in this article. © Crown copyright 2015.

  18. FIELD CALIBRATION OF A TLD ALBEDO DOSEMETER IN THE HIGH-ENERGY NEUTRON FIELD OF CERF.

    PubMed

    Haninger, T; Kleinau, P; Haninger, S

    2016-07-15

    The new albedo dosemeter-type AWST-TL-GD 04 has been calibrated in the CERF neutron field (Cern-EU high-energy Reference Field). This type of albedo dosemeter is based on thermoluminescent detectors (TLDs) and used by the individual monitoring service of the Helmholtz Zentrum München (AWST) since 2015 for monitoring persons, who are exposed occupationally against photon and neutron radiation. The motivation for this experiment was to gain a field specific neutron correction factor Nn for workplaces at high-energy particle accelerators. Nn is a dimensionless factor relative to a basic detector calibration with (137)Cs and is used to calculate the personal neutron dose in terms of Hp(10) from the neutron albedo signal. The results show that the sensitivity of the albedo dosemeter for this specific neutron field is not significantly lower as for fast neutrons of a radionuclide source like (252)Cf. The neutron correction factor varies between 0.73 and 1.16 with a midrange value of 0.94. The albedo dosemeter is therefore appropriate to monitor persons, which are exposed at high-energy particle accelerators.

  19. Astronaut Charles Conrad as test subject for Lower Body Negative Pressure

    NASA Image and Video Library

    1973-06-09

    S73-27707 (9 June 1973) --- Astronaut Charles Conrad Jr., Skylab 2 commander, serves as test subject for the Lower Body Negative Pressure (MO92) Experiment, as seen in this reproduction taken from a color television transmission made by a TV camera aboard the Skylab 1/2 space station cluster in Earth orbit. Scientist-astronaut Joseph P. Kerwin, Skylab 2 science pilot, assists Conrad into the LBNP device. Kerwin served as monitor for the experiment. The purpose of the MO92 experiment is to provide information concerning the time course of cardiovascular adaptation during flight, and to provide inflight data for predicting the degree of orthostatic intolerance and impairment of physical capacity to be expected upon return to Earth environment. The data collected in support of MO92 blood pressure, heart rate, body temperature, vectorcardiogram, LBNPD pressure, leg volume changes, and body weight. Photo credit: NASA

  20. Artist's concept of Astronauts Kerwin and Conrad repairing solar array wing

    NASA Technical Reports Server (NTRS)

    1975-01-01

    An artist's concept illustrating a scene during the June 7, 1973 Skylab 2 extravehicular activity (EVA) in Earth orbit when Astronaut Joseph P. Kerwin (larger figure) and Charles Conrad Jr. cut the aluminum strapping which prevented the Skylab Orbital Workshop solar array system wing from deploying. The painting is by artist Paul Fjeld. The action portrayed here is about two to four seconds after using the beam erection tether, as the two crewmen broke the frozen SAS beam actuators.

  1. Testing the direct ion storage dosemeter for personal dosimetry in a nuclear research centre and a hospital.

    PubMed

    Vanhavere, F; Covens, P

    2010-03-01

    The direct ion storage (DIS) dosemeter can have some clear advantages in personal dosimetry. Before introducing the DIS into practice in the dosimetry service, a series of tests was performed on the linearity, angular and energy dependence, temperature influences and hard resets. After that, for several months, the DIS dosemeters were worn in parallel with the legal dosemeters (thermoluminescent badge) in a nuclear research centre and in several departments of a university hospital. The conclusions are that the DIS has good characteristics to be used as legal personal dosemeter, and that the comparison with the TLD badge is good. Only in interventional radiology and cardiology fields the DIS gives significant lower values than the TLD badge.

  2. Performance of a PADC personal neutron dosemeter at simulated and real workplace fields of the nuclear industry.

    PubMed

    Fiechtner, A; Boschung, M; Wernli, C

    2007-01-01

    In the framework of the EVIDOS (Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields) project, funded by the EC, measurements with PADC personal neutron dosemeters were carried out at several workplace fields of the nuclear industry and at simulated workplace fields. The measured personal neutron dose equivalents of the PADC personal neutron dosemeter are compared with values that were assessed within the EVIDOS project by other partners. The detection limits for different spectra types are given. In cases were the neutron dose was too low to be measured by the PADC personal neutron dosemeter, the response is estimated by convoluting the responses to monoenergetic neutrons with the dose energy distribution measured within EVIDOS. The advantages and limitations of the PADC personal neutron dosemeter are discussed.

  3. Application of TL dosemeters for dose distribution measurements at high temperatures in nuclear reactors.

    PubMed

    Osvay, M; Deme, S

    2006-01-01

    Al2O3:Mg,Y ceramic thermoluminescence dosemeters were developed at the Institute of Isotopes for high dose applications at room temperatures. The glow curve of Al2O3:Mg,Y exhibits two peaks--one at 250 degrees C (I) and another peak at approximately 400 degrees C (II). In order to extend the application of these dosemeters to high temperatures, the effect of irradiation temperature was investigated using temperature controlled heating system during high dose irradiation at various temperatures (20-100 degrees C). The new calibration and measuring method has been successfully applied for dose mapping within the hermetic zone of the Paks Nuclear Power Plant even at high temperature parts of blocks.

  4. Application of solid state integrating dosemeters to the determination of biologically equivalent doses in space.

    PubMed

    Yasuda, H

    2002-01-01

    If the biological responses are well approximated by the efficiencies of solid-state integrating dosemeters (SSID), the biologically equivalent doses can be simply estimated using SSID. For demonstrating the applicability of this method to space radiation dosimetry, biologically equivalent doses for two biological endpoints (enzyme inactivation and cell survival) were evaluated in the 8.8 d Shuttle-Mir mission (STS-89) using three commercial thermoluminescence dosemeters: Mg2SiO4:Tb, BeO:Na and 7LiF:Mg,Ti. The approximate biologically equivalent doses at two positions in the Spacehab module were found to be significantly different for trypsin inactivation, whereas they were almost identical for mammalian cell survival.

  5. Dose imaging with gel-dosemeter layers: optical analysis and dedicated software.

    PubMed

    Gambarini, G; Carrara, M; Gay, S; Tomatis, S

    2006-01-01

    In radiotherapy involving thermal and epithermal neutrons, the knowledge of dose distributions, with separation of the contribution of each secondary radiation component, is of utmost importance. Layers of Fricke-Xylenol-Orange-infused gel dosemeters give the possibility of achieving such requirements because, owing to the layer-geometry, enriching or depleting the gel matrix of suitable isotopes does not sensibly alter neutron transport. The dosimetry method has been critically re-examined with the aim of improving its suitability to boron neutron capture therapy (BNCT) requirements, as it applies to the protocol of measurement and analysis, the sensitivity of the method and the range of the linearity of the dosemeters. Software has been developed and studied to obtain automatically the images of the various dose components with the established separation procedure.

  6. Monitoring radiation dose to the hands in nuclear medicine: location of dosemeters.

    PubMed

    Williams, E D; Laird, E E; Forster, E

    1987-07-01

    The relatively high radiation dose which can be received by the hands of staff in nuclear medicine departments means that in many departments it is necessary to monitor such doses. A convenient method is to use a TLD sachet in a plastic strip around a finger. This study was done to determine whether a dosemeter worn at the base of the middle finger was adequate to monitor the dose to the surface of the whole hand. Dosemeters were worn at the finger tips, finger base and palm of both hands, on two people while preparing and dispensing radio-pharmaceuticals, and two others while giving injections using syringe shields. The pattern of distribution of radiation does to the hands was similar for all workers and for both types of work. A single, convenient site (base of middle finger) may therefore be used for monitoring radiation dose to the hand.

  7. Determination of the response function for two personal neutron dosemeter designs based on PADC.

    PubMed

    Mayer, S; Assenmacher, F; Boschung, M

    2014-10-01

    Since 1998 neutron dosimetry based on PADC (poly allyl diglycol carbonate) is done with a so-called original Paul Scherrer Institute (PSI) design at PSI. The original design (i.e. holder) was later changed. Both designs are optimised for use in workplaces around high-energy accelerators, where the neutron energy spectra are dominated by fast neutrons ranging up to some 100 MeV. In addition to the change of the dosemeter design a new evaluation method based on a microscope scanning technique has been introduced and the etching conditions have been optimised. In the present work, the responses obtained with the original and the new dosemeter designs are compared for fields of radionuclide sources and monoenergetic reference fields using the new evaluation method. The response curves in terms of the personal dose equivalent for normally incident neutrons were built as functions of the incident neutron energy.

  8. Characterization of workplaces in interventional radiology using active dosemeters ALARA OD.

    PubMed

    Prlić, I; Surić-Mihić, M; Milković-Kraus, S; Mestrović, T; Vrtar, M

    2007-01-01

    Because of progressive development and extended use of interventional radiology (IR) procedures it is highly recommended that all individuals involved in the process should be aware of the potential for both stochastic and deterministic effects due to occupational exposure. IR procedures are performed in such a manner that certain number of medical staff are always needed near the patient, near the X-ray unit. The new challenge to regular radiation protection is to ensure 'safe' working environment in such radiation X-ray field geometry. In this work the patient is physically regarded as a secondary radiation source emitting scattered X-rays. Passive dosemeters will give us clear data only about the monthly integrated occupational dose; there is concern over the frequency and duration, actual pattern of receiving this dose. We have developed active electronic dosemeter (AED) device, which provides additional dosimetry data about the frequency and duration of professional low level X-ray exposure burden.

  9. Brazilian gamma-neutron dosemeter: response to 241AmBe and 252Cf neutron sources.

    PubMed

    Souto, E B; Campos, L L

    2011-03-01

    With the aim of improving the monitoring of workers potentially exposed to neutron radiation in Brazil, the IPEN/CNEN-SP in association with PRO-RAD designed and developed a passive individual gamma-neutron mixed-field dosemeter calibrated to be used to (241)AmBe sources. To verify the dosimetry system response to different neutron spectra, prototypes were irradiated with a (252)Cf source and evaluated using the dose-calculation algorithm developed for (241)AmBe sources.

  10. The 12B counter: an active dosemeter for high-energy neutrons.

    PubMed

    Leuschner, A

    2005-01-01

    High-energy accelerators can produce strong time-structured radiation fields. Such dose shots are generated at linear machines with low duty cycles as well as at circular machines when complete fills are instantaneously lost. The main dose component behind thick shielding is due to high-energy neutrons occurring at that time structure. Dosemeters based on Geiger-Mueller tubes or proportional counters fail here completely. The 12B counter, a novel dosemeter made of a plastic scintillator using carbon activation for event-like exposure, has been introduced. High-energy neutrons activate the carbon nuclei by three inelastic reactions. The decay patterns with half-lives between 20 ms and 20 min can be exploited depending on the time structure of the radiation field. The response of the 12B counter was measured along with some other dosemeters, both active and passive, in the radiation field behind the lateral concrete shielding of a 7.5 GeV proton transfer line.

  11. Mixed high energy photon and electron radiation fields for calibrating radiation protection dosemeters.

    PubMed

    Büermann, L; Gargioni, E; Kramer, H M

    2001-01-01

    According to ISO 4037-3, calibrations of radiation protection dosemeters with photon radiation of energies above 3 MeV are performed under conditions of charged particle equilibrium. No information is provided concerning how to determine the response of dosemeters to radiation fields in the more general case when these conditions are not fulfilled. This paper deals with the production of mixed high energy photon and electron fields characterised by a lack or an excess of charged particles relative to conditions of equilibrium and describes a new procedure for the dosimetry in such fields. Through variation of the charged particle fluence fraction with respect to a nearly constant photon fluence, Hp(10) and H'(10) values varied by up to a factor of 1.74. The above mentioned basic study was utilised in the recent IAEA intercomparison (Co-ordinated Research Project 1996-1998) and EURADOS 'trial performance test' (1996-1998) for individual monitoring of photon radiation in testing response characteristics of individual dosemeters in non-charged particle equilibrium conditions.

  12. Simulated and measured Hp(10) response of the personal dosemeter Seibersdorf.

    PubMed

    Hranitzky, C; Stadtmann, H

    2007-01-01

    The Hp(10) energy response of the personal dosemeter Seibersdorf and its two different filtered LiF:Mg,Ti (TLD-100) thermoluminescence (TL) detectors are investigated. A close-to-reality simulation model of the personal dosemeter badge including the wrapped detector card was implemented with the MCNP Monte Carlo N-particle transport code. The comparison of measured and computationally calculated response using a semi-empirical TL efficiency function is carried out to provide information about the quality of the results of both methods, experiment and simulation. Similar to the experimental calibration conditions, the irradiation of dosemeters centred on the front surface of the International Organization for Standardization (ISO) water slab phantom is simulated using ISO-4037 reference photon radiation qualities with mean energies between 24 keV and 1.25 MeV and corresponding ISO conversion coefficients. The comparison of the simulated and measured relative Hp(10) energy responses resulted in good agreement within some percent except for the filtered TL element at lower photon energies.

  13. Individual monitoring in nuclear medicine therapeutic procedures using extremity dosemeters LiF(Mg, Cu, P).

    PubMed

    Sarti, G; Del Dottore, F; Fabbri, C; Tassinari, L; Pagan, S; Rustignoli, M; Motta, P

    2011-03-01

    Unsealed beta-gamma-emitting sources are used (15 GBq (90)Y each session) in nuclear medicine therapeutic procedures. Inside the manipulation cell and while giving the injection to the patient, the skin exposure is very high; electron radiation field is not homogeneous and thus the exposure of the extremities is not uniform. Particular individual monitoring is adopted: single thermoluminescence dosemeter, wrapped in polyethylene film and placed on an adhesive tape, is positioned on the tip of the fingers; 6-10 dosemeters are assigned to each operator per session. The energy and angle response is studied for X-ray spectra, (90)Sr/Y and (204)Tl--a unique mean calibration factor is calculated in order to estimate H(p)(0.07). Performance of dosemeter is analysed according to ISO 62387-1(2007) and the combined uncertainty (calculated using the Monte Carlo method) results lie in the order of 11 %. This method reveals the critical step of manipulation and administration and ensures that dose limits are not exceeded.

  14. Investigation of a BeO-based optically stimulated luminescence dosemeter.

    PubMed

    Sommer, M; Henniger, J

    2006-01-01

    The optical sensitivity of BeO-based luminophors has been well-known for many years. The optical stimulation of BeO with blue light is most effective. Then the dosemeters emit luminescent light in the ultraviolet-range around 325 nm. Matched on these facts a simple optically stimulated luminescence (OSL) treatment has been developed. Intense blue light-emitting diodes are used for cw-stimulation. A Hamamatsu solar blind photomultiplier detects the OSL-light. Good separation of both spectral ranges by optical filters is very important. The dosemeter has a linear dose response between approximately 20 muGy and >10 Gy. It was suggested, that a modification of stimulation conditions would allow measurements down to 1 muGy. Fading, photon energy dependence and reproducibility of OSL-signal correspond well with requirements to clinical and personal dosemeters. In addition, basic questions of the OSL-process in BeO have been investigated. A relevant point of interest was the dependency of the OSL-signal on stimulation power.

  15. FIRST EURADOS INTERCOMPARISON EXERCISE OF EYE LENS DOSEMETERS FOR MEDICAL APPLICATIONS.

    PubMed

    Clairand, I; Ginjaume, M; Vanhavere, F; Carinou, E; Daures, J; Denoziere, M; Silva, E H; Roig, M; Principi, S; Van Rycheghem, L

    2016-09-01

    In the context of the decrease in the eye lens dose limit for occupational exposure to 20 mSv per year stated by the recent revision of the European Basic Safety Standards Directive 2013/59/EURATOM, the European Radiation Dosimetry Group (EURADOS) has organised in 2014, for the first time, an intercomparison exercise for eye lens dosemeters. The main objective was to assess the capabilities of the passive eye lens dosemeters currently in use in Europe for occupational monitoring in medical fields. A total of 20 European individual monitoring services from 15 different countries have participated. The dosemeters provided by the participants were all composed of thermoluminescent detectors, of various types and designs. The irradiations were carried out with several photon fields chosen to cover the energy and angle ranges encountered in medical workplace. Participants were asked to report the doses in terms of Hp(3) using their routine protocol. The results provided by each participant were compared with the reference delivered doses. All the results were anonymously analysed. Results are globally satisfactory since, among the 20 participants, 17 were able to provide 90 % of their response in accordance with the ISO 14146 standard requirements.

  16. Being a Stranger and the Strangeness of Being: Joseph Conrad's "The Secret Sharer" as an Allegory of Being in Education

    ERIC Educational Resources Information Center

    Schwieler, Elias

    2013-01-01

    Joseph Conrad's "The Secret Sharer" has often been associated with what can be called initiation stories. However, in this article I argue that Conrad's text is more than that. It can, I suggest, be read as an allegory of the inaccessibility to reveal the essence of being in command, being in education, and also the…

  17. Being a Stranger and the Strangeness of Being: Joseph Conrad's "The Secret Sharer" as an Allegory of Being in Education

    ERIC Educational Resources Information Center

    Schwieler, Elias

    2013-01-01

    Joseph Conrad's "The Secret Sharer" has often been associated with what can be called initiation stories. However, in this article I argue that Conrad's text is more than that. It can, I suggest, be read as an allegory of the inaccessibility to reveal the essence of being in command, being in education, and also the…

  18. CONRAD--a software framework for cone-beam imaging in radiology.

    PubMed

    Maier, Andreas; Hofmann, Hannes G; Berger, Martin; Fischer, Peter; Schwemmer, Chris; Wu, Haibo; Müller, Kerstin; Hornegger, Joachim; Choi, Jang-Hwan; Riess, Christian; Keil, Andreas; Fahrig, Rebecca

    2013-11-01

    In the community of x-ray imaging, there is a multitude of tools and applications that are used in scientific practice. Many of these tools are proprietary and can only be used within a certain lab. Often the same algorithm is implemented multiple times by different groups in order to enable comparison. In an effort to tackle this problem, the authors created CONRAD, a software framework that provides many of the tools that are required to simulate basic processes in x-ray imaging and perform image reconstruction with consideration of nonlinear physical effects. CONRAD is a Java-based state-of-the-art software platform with extensive documentation. It is based on platform-independent technologies. Special libraries offer access to hardware acceleration such as OpenCL. There is an easy-to-use interface for parallel processing. The software package includes different simulation tools that are able to generate up to 4D projection and volume data and respective vector motion fields. Well known reconstruction algorithms such as FBP, DBP, and ART are included. All algorithms in the package are referenced to a scientific source. A total of 13 different phantoms and 30 processing steps have already been integrated into the platform at the time of writing. The platform comprises 74.000 nonblank lines of code out of which 19% are used for documentation. The software package is available for download at http://conrad.stanford.edu. To demonstrate the use of the package, the authors reconstructed images from two different scanners, a table top system and a clinical C-arm system. Runtimes were evaluated using the RabbitCT platform and demonstrate state-of-the-art runtimes with 2.5 s for the 256 problem size and 12.4 s for the 512 problem size. As a common software framework, CONRAD enables the medical physics community to share algorithms and develop new ideas. In particular this offers new opportunities for scientific collaboration and quantitative performance comparison

  19. Evaluations of absorbed dose ratio factor of Al2O3 dosemeter in radiotherapy photon beams using cavity theory.

    PubMed

    Zhu, Jinhan; Chen, Shaowen; Chen, Lixin; Liu, Xiaowei

    2012-12-01

    The aim of the work was to evaluate the absorbed dose ratio factor f(md) of an Al(2)O(3) dosemeter to water in photon radiotherapy beams using cavity theory. Burlin theory was used for calculating of this ratio. The effective mass attenuation coefficient β was obtained by comparing Monte Carlo simulations in monoenergetic photon beams. The evaluations of the absorbed dose ratio factor f(md) were studied for Al(2)O(3) dosemeters of different sizes, which were placed at various depths of the water phantom in different radiation field sizes of Mohan's 6, 10 and 15-MV X-rays. Beyond the build-up region, the variation of f(md) increases by 0.25 % as the depth increases from 4 to 10 cm. The maximum variation due to different dosemeter sizes is 8.3 %. The difference in the f(md) due to different radiation field sizes is 1.5 %. The effect of the dosemeter size cannot be neglected. The difference in the f(md) due to the radiation field sizes of different beams would increase as the dosemeter size increases.

  20. Performance of a personal neutron dosemeter based on direct ion storage at workplace fields in the nuclear industry.

    PubMed

    Boschung, M; Fiechtner, A; Wernli, C

    2007-01-01

    In the framework of the EVIDOS project, funded by the EC, measurements were carried out using dosemeters, based on ionisation chambers with direct ion storage (DIS-N), at several workplace fields, namely, at a fuel processing plant, a boiling and a pressurised water reactor, and near transport and storage casks. The measurements and results obtained with the DIS-N in these workplaces, which are representative for the nuclear industry, are described in this study. Different dosemeter configurations of converter and shielding materials were considered. The results are compared with values for personal dose equivalent which were assessed within the EVIDOS project by other partners. The advantages and limitations of the DIS-N dosemeter are discussed.

  1. PERSONNEL DOSIMETER

    DOEpatents

    Birkhoff, R.D.; Hubbell, H.H. Jr.; Johnson, R.M.

    1959-02-24

    A personnel dosimeter sensitive to both gamma and beta radiation is described. The dosimeter consists of an electrical conductive cylinder having a wall thickness of substantially 7 milligrams per square centimeter and an electrode disposed axially within the cylinder and insulated therefrom to maintain a potential impressed between the electrode and the cylinder. A cylindrical perforated shield provided with a known percentage of void area is disposed concentrically about the cylinder. The shield is formed of a material which does not contain more than 15 percent of an element higher than atomic weight 13. The dose actually received is at most the gamma dose plus the beta dose indicated by discharge of the dosimeter divided by the known percentage.

  2. Energy and angular dependence of active-type personal dosemeter for high-energy neutron.

    PubMed

    Rito, Hirotaka; Yamauchi, Tomoya; Oda, Keiji

    2011-07-01

    In order to develop an active-type personal dosemeter having suitable sensitivity to high-energy neutrons, the characteristic response of silicon surface barrier detector has been investigated experimentally and theoretically. An agreement of the shape of pulse-height distribution, its change with radiator thickness and the relative sensitivity was confirmed between the calculated and experimental results for 14.8-MeV neutrons. The angular dependence was estimated for other neutron energies, and found that the angular dependence decreased with the incident energy. The reason was also discussed with regard to the radiator thickness relative to maximum range of recoil protons.

  3. Development of a new electronic personal neutron dosemeter using a CMOS active pixel sensor.

    PubMed

    Trocmé, M; Higueret, S; Husson, D; Nourreddine, A; Lê, T D

    2007-01-01

    A CMOS active pixel sensor, originally designed for the tracking of minimum ionising charged particles in high-energy physics, has been recently used for the detection of fast neutrons. Data were taken at the IRSN Cadarache facility with a (241)Am-Be ISO source and a polyethylene radiator. A high-intrinsic efficiency (1.2 x 10(-3)) has been obtained. It is in good agreement with both calculations and a MCNPX Monte Carlo simulation. This experiment paves the way for a fully electronic personal neutron dosemeter.

  4. Dose evaluation in criticality accidents using response of Panasonic TL personal dosemeters (UD-809/UD-802).

    PubMed

    Zeyrek, C T; Gündüz, H

    2012-09-01

    This study gives the results of dosimetry measurements carried out in the Silène reactor at Valduc (France) with neutron and photon personal thermoluminescence dosemeters (TLDs) in mixed neutron and gamma radiation fields, in the frame of the international accident dosimetry intercomparison programme in 2002. The intercomparison consisted of a series of three irradiation scenarios. The scenarios took place at the Valduc site (France) by using the Silène experimental reactor. For neutron and photon dosimetry, Panasonic model UD-809 and UD-802 personal TLDs were used together.

  5. Use of a dual-labelled oligonucleotide as a DNA dosemeter for radiological exposure detection.

    PubMed

    Wood, T; Lewis, B J; McDermott, K; Bennett, L G I; Avarmaa, K; Corcoran, E C; Wilkinson, D; Jones, A; Jones, T; Kennedy, E; Prud'homme-Lalonde, L; Boudreau, D; Gravel, J-F; Drolet, C; Kerr, A; Schreiner, L J; Pierre, J R M; Blagoeva, R; Veres, T

    2012-01-01

    A reporter molecule consisting of a synthetic oligonucleotide is being characterised for a novel damage detection scenario for its potential use as a field-deployable, personal deoxyribonucleic acid (DNA) dosemeter for radiation detection. This dosemeter is devoid of any biological properties other than being naked DNA and therefore has no DNA repair capabilities. It supports biodosimetry techniques, which require lengthy analysis of cells from irradiated individuals, and improves upon inorganic dosimetry, thereby providing for a more relevant means of measuring the accumulated dose from a potentially mixed-radiation field. Radiation-induced single strand breaks (SSBs) within the DNA result in a quantifiable fluorescent signal. Proof of concept has been achieved over 250 mGy-10 Gy dose range in radiation fields from ⁶⁰Co, with similar results seen using a linear accelerator X-ray source. Further refinements to both the molecule and the exposure/detection platform are expected to lead to enhanced levels of detection for mixed-field radiological events.

  6. Efficiency of a radiophotoluminescence glass dosemeter for low-earth-orbit space radiation.

    PubMed

    Yasuda, H; Fujitaka, K

    2002-01-01

    Chips of a radiophotoluminescence glass dosemeter (RPLG) were used for measurements of space radiation during a 9.8 d Shuttle-Mir mission (STS-91) at an altitude of 400 km and an inclination of 51.65 degrees. Two of RPLG chips were put into each of 59 positions in or on a life-size human phantom. The RPLG values equivalent to 137Cs gamma ray absorbed doses were found to be systematically lower than those of a Mg2SiO4:Tb thermoluminescence dosemeter (TDMS). In comparison with the organ or tissue absorbed dose and dose equivalent values that were estimated using a combination of TDMS and plastic nuclear track detectors, the efficiencies of the RPLG chips were about 80% for the water absorbed dose and about 40% for the dose equivalent. Whereas the percentage values will change during different missions, such additional information obtained from small RPLG chips is useful for improving the reliability of radiation dosimetry in space.

  7. Photon energy dependence of three fortuitous dosemeters from personal electronic devices, measured by optically stimulated luminescence.

    PubMed

    Beerten, Koen; Vanhavere, Filip

    2010-08-01

    New data are presented with regard to the relative OSL sensitivity of three different emergency dosemeters irradiated to various photon energies approximately between 48 and 1250 keV using blue excitation light. Investigated components extracted from commonly worn objects include those from USB flash drives (alumina substrate), mobile phones (Ba-rich silicate) and credit cards (chip card module). Several basic properties have been investigated such as the overall radiation sensitivity, the shape of the decay curve and fading of the OSL signal. An increase of the sensitivity for low energies relative to (60)Co gamma rays can be observed for the three dosemeters, the increase being very pronounced for the Ba-rich component (factor of 10) and less pronounced for the chip card module (factor of 2). It is concluded that proper dose correction factors for photon energy have to be applied in order to accurately determine the absorbed dose to tissue. The OSL sensitivity to neutron irradiation was investigated as well, but this was found to be less than the gamma sensitivity.

  8. Efficiency of a radiophotoluminescence glass dosemeter for low-earth-orbit space radiation

    NASA Technical Reports Server (NTRS)

    Yasuda, H.; Fujitaka, K.; Badhwar, G. D. (Principal Investigator)

    2002-01-01

    Chips of a radiophotoluminescence glass dosemeter (RPLG) were used for measurements of space radiation during a 9.8 d Shuttle-Mir mission (STS-91) at an altitude of 400 km and an inclination of 51.65 degrees. Two of RPLG chips were put into each of 59 positions in or on a life-size human phantom. The RPLG values equivalent to 137Cs gamma ray absorbed doses were found to be systematically lower than those of a Mg2SiO4:Tb thermoluminescence dosemeter (TDMS). In comparison with the organ or tissue absorbed dose and dose equivalent values that were estimated using a combination of TDMS and plastic nuclear track detectors, the efficiencies of the RPLG chips were about 80% for the water absorbed dose and about 40% for the dose equivalent. Whereas the percentage values will change during different missions, such additional information obtained from small RPLG chips is useful for improving the reliability of radiation dosimetry in space.

  9. INFLUENCE OF DIFFERENT TYPES OF PHANTOMS ON THE CALIBRATION OF DOSEMETERS FOR EYE LENS DOSIMETRY.

    PubMed

    Yoshitomi, H; Kowatari, M

    2016-09-01

    Both a cylinder and a slab phantom have been recommended to be used as calibration phantoms for eye lens dosimetry in the International Atomic Energy Agency TECDOC. This study describes investigations on the influence of the type of phantom on the calibration of dosemeters. In order to fulfil the purpose, backscatter radiation from practically used water-filled phantoms was evaluated by calculations and experiments. For photons, the calculations showed that the cylinder phantom had 10 % lower backscattered effect at maximum than a slab phantom, and simulated well the backscattered effect of the human head or neck to within ±10 %. The irradiation results of non-filtered optically stimulated luminescence and radio-photoluminescence glass dosemeters indicated that the differences of the calibration factors between the two types of phantoms were up to 20 and 10 %, respectively, reflecting the response to backscattered photons. For electrons, no difference was found between the two types of phantoms. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. ENEA extremity dosemeter based on LiF(Mg,Cu,P) to evaluate Hp(3,alpha).

    PubMed

    Mariotti, F; Fantuzzi, E; Morelli, B; Gualdrini, G; Botta, M C; Uleri, G; Bordy, J M; Denoziere, M

    2011-03-01

    Recent epidemiological studies suggest a rather low-dose threshold (<0.5 Gy) for the induction of a cataract of the eye lens. Some other studies even assume that there is no threshold at all. Therefore, protection measures have to be optimised and current dose limits for the eye lens may be reduced in the future. ICRP Publication 103 on H(p)(d), in §(136), reads that '… a depth d = 3 mm has been proposed for the rare case of monitoring the dose to the lens of the eye. In practice, however, H(p)(3) has rarely been monitored and H(p)(0.07) can be used for the same monitoring purpose… '. As recommended on the EU 'Technical recommendations for monitoring individuals occupationally exposed to external radiation', a test on the ENEA TL extremity dosemeter is herein reported. The results within the actual EU founded Optimization of RAdiation protection for MEDical staff (ORAMED) Project, whose WP2 is aimed at the quantity H(p)(3) and eye lens dosimetry in practice, are taken into account. The paper summarises the main aspects of the study carried out at ENEA-Radiation Protection Institute (Bologna, Italy) to provide practical solutions (in the use and the design) to evaluate the response of the ENEA TL extremity dosemeter in terms of H(p)(3).

  11. COMPARISON METHODOLOGIES FOR CALIBRATION OF Hp(10) PERSONAL DOSEMETERS USING ISO 4037 AND ISO 29661 STANDARDS.

    PubMed

    Cardoso, J; Santos, L; Carvalhal, G; Oliveira, C

    2016-09-01

    The calibration of electronic personal dosemeters at the Portuguese ionizing radiation metrology laboratory uses the standard IEC 61526 for calibration methodology. This standard describes the irradiation geometry for testing and indicates that the standard ISO 4037-1, 2, 3 and 4 should be used. The ISO 4037 establishes that the reference point of test is a point in the radiation monitor, known or established, and the calibration phantom should be placed on its back in order to simulate the trunk body. Recently, ISO published another standard, the ISO 29661, that changes the reference point from the radiation monitor to the front face of the calibration phantom. The aim of this work is to present the result of the comparison of these two methodologies on personal dosemeters from five different manufacturers. The work shows differences in the Hp(10) response up to 4% resulting from the two different reference point concepts. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Efficiency of a radiophotoluminescence glass dosemeter for low-earth-orbit space radiation

    NASA Technical Reports Server (NTRS)

    Yasuda, H.; Fujitaka, K.; Badhwar, G. D. (Principal Investigator)

    2002-01-01

    Chips of a radiophotoluminescence glass dosemeter (RPLG) were used for measurements of space radiation during a 9.8 d Shuttle-Mir mission (STS-91) at an altitude of 400 km and an inclination of 51.65 degrees. Two of RPLG chips were put into each of 59 positions in or on a life-size human phantom. The RPLG values equivalent to 137Cs gamma ray absorbed doses were found to be systematically lower than those of a Mg2SiO4:Tb thermoluminescence dosemeter (TDMS). In comparison with the organ or tissue absorbed dose and dose equivalent values that were estimated using a combination of TDMS and plastic nuclear track detectors, the efficiencies of the RPLG chips were about 80% for the water absorbed dose and about 40% for the dose equivalent. Whereas the percentage values will change during different missions, such additional information obtained from small RPLG chips is useful for improving the reliability of radiation dosimetry in space.

  13. Development of advanced-type multi-functional electronic personal dosemeter.

    PubMed

    Nunomiya, T; Abe, S; Aoyama, K; Nakamura, T

    2007-01-01

    An advanced-type small, light, multi-functional electronic personal dosemeter has been developed using silicon semiconductor radiation detectors for dose management of workers at nuclear power plants and accelerator facilities. This dosemeter is 62 x 82 x 27 mm(3) in size and approximately 130 g in weight, which is capable of measuring personal gamma ray and neutron dose equivalents, Hp(10), simultaneously. The neutron dose equivalent can be obtained using two types of silicon semiconductors: a slow-neutron sensor (<1 MeV) and a fast-neutron sensor (>1 MeV). The slow neutron sensor is a 10 x 10 mm(2) p-type silicon on which a natural boron layer is deposited around an aluminium electrode. The fast neutron sensor is also a 10 x 10 mm(2) p-type silicon crystal on which an amorphous silicon hydride is deposited. The neutron energy response corresponding to the fluence-to-dose-equivalent conversion coefficient given by ICRP Publication 74 has been evaluated using a monoenergetic neutron source from 250 keV to 15 MeV at the Fast Neutron Laboratory of Tohoku University. As the result, the Hp(10) response to neutrons in the energy range of 250 keV and 4.4 MeV within +/-50% difference has been obtained.

  14. Circulation of images and graphic practices in Renaissance natural history: the example of Conrad Gessner.

    PubMed

    Egmond, Florike; Kusukawa, Sachiko

    2016-01-01

    Conrad Gessner's Historia animalium is a compilation of information from a variety of sources: friends, correspondents, books, broadsides, drawings, as well as his own experience. The recent discovery of a cache of drawings at Amsterdam originally belonging to Gessner has added a new dimension for research into the role of images in Gessner's study of nature. In this paper, we examine the drawings that were the basis of the images in the volume of fishes. We uncovered several cases where there were multiple copies of the same drawing of a fish (rather than multiple drawings of the samefish), which problematizes the notion of unique "original" copies and their copies. While we still know very little about the actual mechanism of, or people involved in, commissioning or generating copies of drawings, their very existence suggests that the images functioned as an important medium in the circulation of knowledge in the early modern period.

  15. Internal dose assessments: uncertainty studies and update of ideas guidelines and databases within CONRAD project.

    PubMed

    Marsh, J W; Castellani, C M; Hurtgen, C; Lopez, M A; Andrasi, A; Bailey, M R; Birchall, A; Blanchardon, E; Desai, A D; Dorrian, M-D; Doerfel, H; Koukouliou, V; Luciani, A; Malatova, I; Molokanov, A; Puncher, M; Vrba, T

    2008-01-01

    The work of Task Group 5.1 (uncertainty studies and revision of IDEAS guidelines) and Task Group 5.5 (update of IDEAS databases) of the CONRAD project is described. Scattering factor (SF) values (i.e. measurement uncertainties) have been calculated for different radionuclides and types of monitoring data using real data contained in the IDEAS Internal Contamination Database. Based upon this work and other published values, default SF values are suggested. Uncertainty studies have been carried out using both a Bayesian approach as well as a frequentist (classical) approach. The IDEAS guidelines have been revised in areas relating to the evaluation of an effective AMAD, guidance is given on evaluating wound cases with the NCRP wound model and suggestions made on the number and type of measurements required for dose assessment.

  16. Feasibility of a neutron detector-dosemeter based on single-event upsets in dynamic random-access memories.

    PubMed

    Phillips, G W; August, R A; Campbell, A B; Nelson, M E; Price, J L; Guardala, N A; Moscovitch, M

    2002-01-01

    The feasibility was investigated of a solid-state neutron detector/dosemeter based on single-event upset (SEU) effects in dynamic random-access memories (DRAMs), commonly used in computer memories. Such a device, which uses a neutron converter material to produce a charged particle capable of causing an upset, would be light-weight, low-power, and could be read simply by polling the memory for bit flips. It would have significant advantages over standard solid-state neutron dosemeters which require off-line processing for track etching and analysis. Previous efforts at developing an SEU neutron detector/dosemeter have suffered from poor response, which can be greatly enhanced by selecting a modern high-density DRAM chip for SEU sensitivity and by using a thin 10B film as a converter. Past attempts to use 10B were not successful because the average alpha particle energy was insufficient to penetrate to the sensitive region of the memory. This can be overcome by removing the surface passivation layer before depositing the 10B film or by implanting 10B directly into the chip. Previous experimental data show a 10(3) increase in neutron sensitivity by chips containing borosilicate glass, which could be used in an SEU detector. The results are presented of simulations showing that the absolute efficiency of an SEU neutron dosemeter can be increased by at least a factor of 1000 over earlier designs.

  17. Performance of Panasonic ZP-1460 Electronic Personal Dosemeter under Exposure Conditions Likely to be Found at Fukushima Daiichi Nuclear Power Plant

    NASA Astrophysics Data System (ADS)

    Tsujimura, Norio; Yoshida, Tadayoshi; Hoshi, Katsuya; Momose, Takumaro

    A study on the performance of the Panasonic ZP-1460 electronic personal dosemeter, the model used in the aftermath of the Fukushima Daiichi nuclear power plant accident in March 2011, was conducted under actual exposure situations likely encountered in the plant. The tests pertained to (1) the dose rate response over dose rates >100 mSv/h and (2) the angular response on an anthropomorphic phantom exposed to the rotational and isotropic irradiation geometries. The test results confirmed that the dosemeter provides Hp(10) as a reasonably close estimate of the effective dose for any exposure geometries. The dosemeter response data evaluated in this study can be utilized for converting dosemeter readings to the absorbed dose to any organs and tissues for epidemiologic purposes.

  18. The Lease of R/V (Research Vessel) CONRAD for Geophysical and Geological Research in the South Atlantic Ocean.

    DTIC Science & Technology

    1987-08-01

    Ai4 168 THE LEASE OF /V (RESEARCH VESSEL) CONRAD FOR / GEOPHYSICAL AND GEOLOGICAL (U) LAMONT-DOHERTY B " HGEOLOGICAL OBSERVATORY PALISADES NV AUG...Research in __ the South Atlantic Ocean 12 PSO’NAL ALUTHOR(S) [Za 0.Or RiPCRT i~ TIMjCQRED 4 DATE OF REPQ.R7 c’ar, Month. Day) 5 PAGE COUNT Final FIRO

  19. Exposure of aircraft crew to cosmic radiation: on-board intercomparison of various dosemeters.

    PubMed

    Bottollier-Depois, J-F; Trompier, F; Clairand, I; Spurny, F; Bartlett, D; Beck, P; Lewis, B; Lindborg, L; O'Sullivan, D; Roos, H; Tommasino, L

    2004-01-01

    Owing to their professional activity, flight crews may receive a dose of some millisieverts within a year; airline passengers may also be concerned. The effective dose is to be estimated using various experimental and calculation tools. The European project DOSMAX (Dosimetry of Aircrew Exposure during Solar Maximum) was initiated in 2000 extending to 2004 to complete studies over the current solar cycle during the solar maximum phase. To compare various dosemeters in real conditions simultaneously in the same radiation field, an intercomparison was organised aboard a Paris-Tokyo round-trip flight. Both passive and active detectors were used. Good agreement was observed for instruments determining the different components of the radiation field; the mean ambient dose equivalent for the round trip was 129 +/- 10 microSv. The agreement of values obtained for the total dose obtained by measurements and by calculations is very satisfying.

  20. Dose rate dependency of electronic personal dosemeters measuring X- and gamma-ray radiation.

    PubMed

    McCaffrey, J P; Shen, H; Downton, B

    2008-01-01

    Three models of electronic personal dosemeters (EPDs)-Siemens Mk 2.3, Rados RAD-60S and Vertec Bleeper Sv-were irradiated with seven photon beam qualities: 60Co, 137Cs and the ISO narrow spectrum series X-ray qualities N-250, N-200, N-150, N-60 and N-20. The personal dose equivalent rates delivered to the devices varied between 0.002 and 0.25 mSv s(-1). Measurements were made with the EPDs mounted free-in-air as well as against Lucite and water phantoms. Results for all models of EPDs showed differences in personal dose equivalent energy response for different energies covered by this range of radiation qualities, with different models showing variations from 15 to 65%. In some cases, the personal dose equivalent rate response of these devices varied by a factor of 3 between irradiations at typical calibration dose rates and those normally encountered by nuclear energy workers.

  1. GENERALISATION OF RADIATOR DESIGN TECHNIQUES FOR PERSONAL NEUTRON DOSEMETERS BY UNFOLDING METHOD.

    PubMed

    Oda, K; Nakayama, T; Umetani, K; Kajihara, M; Yamauchi, T

    2016-09-01

    A novel technique for designing a radiator suitable for personal neutron dosemeter based on plastic track detector was discussed. A multi-layer structure has been proposed in the previous report, where the thicknesses of plural polyethylene (PE) layers and insensitive ones were determined by iterative calculations of double integral. In order to arrange this procedure and make it more systematic, unfolding calculation has been employed to estimate an ideal radiator containing an arbitrary hydrogen concentration. In the second step, realistic materials replaced it with consideration of minimisation of the layer number and commercial availability. A radiator consisting of three layers of PE, Upilex and Kapton sheets was finally designed, for which a deviation in the energy dependence between 0.1 and 20 MeV could be controlled within 18 %. An applicability of fluorescent nuclear track detector element has also been discussed.

  2. CHARACTERIZATION OF A THIN SILICON SENSOR FOR ACTIVE NEUTRON PERSONAL DOSEMETERS.

    PubMed

    Takada, M; Nunomiya, T; Nakamura, T; Matsumoto, T; Masuda, A

    2016-09-01

    A thin silicon sensor has been developed for active neutron personal dosemeters for use by aircrews and first responders. This thin silicon sensor is not affected by the funneling effect, which causes detection of cosmic protons and over-response to cosmic neutrons. There are several advantages to the thin silicon sensor: a decrease in sensitivity to gamma rays, an improvement of the energy detection limit for neutrons down to 0.8 MeV and an increase in the sensitivity to fast neutrons. Neutron response functions were experimentally obtained using 2.5 and 5 MeV monoenergy neutron beams and a (252)Cf neutron source. Simulation results using the Monte Carlo N-Particle transport code agree quite well with the experimental ones when an energy deposition region shaped like a circular truncated cone is used in place of a cylindrical region.

  3. Development of confocal laser microscope system for examination of microscopic characteristics of radiophotoluminescence glass dosemeters.

    PubMed

    Maki, Daisuke; Ishii, Tetsuya; Sato, Fuminobu; Kato, Yushi; Yamamoto, Takayoshi; Iida, Toshiyuki

    2011-03-01

    A confocal laser microscope system was developed for the measurement of radiophotoluminescence (RPL) photons emitted from a minute alpha-ray-irradiated area in an RPL glass dosemeter. The system was composed mainly of an inverted-type microscope, an ultraviolet laser, an XY movable stage and photon-counting circuits. The photon-counting circuits were effective in the reduction of the background noise level in the measurement of RPL photons. The performance of this microscope system was examined by the observation of standard RPL glass samples irradiated using (241)Am alpha rays. The spatial resolution of this system was ∼ 3 μm, and with regard to the sensitivity of this system, a hit of more than four to five alpha rays in unit area produced enough amount of RPL photons to construct the image.

  4. Automation of radiation dosimetry using PTW dosemeter and LabVIEW™

    NASA Astrophysics Data System (ADS)

    Weiss, C.; Al-Frouh, K.; Anjak, O.

    2011-10-01

    Automation of UNIDOS "Dosemeter" using personal computer (PC) is discussed in this paper. In order to save time and eliminate human operation errors during the radiation dosimetry, suitable software, using LabVIEW™ graphical programming language, was written to automate and facilitate the processes of measurements, analysis and data storage. The software calculates the calibration factor of the ionization chamber in terms of air kerma or absorbed dose to water according to IAEA dosimetry protocols. It also has the ability to print a calibration certificate. The obtained results using this software are found to be more reliable and flexible than those obtained by manual methods previously employed. Using LabVIEW™ as a development tool is extremely convenient to make things easier when software modifications and improvements are needed.

  5. Track-etch dosemeter response to neutrons up to 300 MeV

    SciTech Connect

    Devine, R.T.; Walker, S.; Staples, P.; Duran, M.; Mundis, R.; Miller, J.

    1996-04-01

    Electro-chemical and chemical track-etch dosemeters were obtained from commercial suppliers and exposed to neutrons produced at the LANTF WNR white neutron source at 15{degree} with no shielding and filtered by polyethylene blocks of 2.5, 5.1, 10.2, 20.3 and 40.6 cin thickness. The neutron spectrum was determined using calculations. Mean energies from 28 to 300 MeV were produced. Dose was calculated from the NCRP-38 flux-to-dose conversion. The results are compared with NTA film which was exposed in the same configuration. The response of track etch dosimeters was found to reach a minimum and then rise as the average neutron energy increased. The response of the NTA film increased as the neutron energy increased.

  6. Two-dimensional differential calibration method for a neutron dosemeter using a thermal neutron beam.

    PubMed

    Matsumoto, Tetsuro; Harano, Hideki; Masuda, Akihiko; Nishiyama, Jun; Matsue, Hideaki; Uritani, Akira; Nunomiya, Tomoya

    2013-08-01

    A new thermal neutron calibration method to experimentally determine the energy response function of a neutron detector using a pulse parallel beam and the time-of-flight (TOF) technique is developed. The calibration method was experimentally demonstrated for a (3)He proportional counter and an electric personal dosemeter using a pulsed thermal neutron beam from the research reactor JRR-3M. The responses of the detectors were successfully obtained as a function of neutron energy. However, detailed information on the detector structure is required to obtain the spatial response distribution for the detector. The authors further propose an improved calibration method obtaining the spatial response distribution using a pulsed narrow beam, the TOF technique and a beam scanning technique.

  7. CHARACTERIZATION OF AN ACTIVE DOSEMETER ACCORDING TO IEC 61526:2010.

    PubMed

    Cardoso, J; Santos, J A M; Santos, L; Alves, J G; Oliveira, C

    2016-09-01

    The active personal dosemeter, RaySafe i2, allows the measurement and record of Hp(10) in real time, every second, via wireless technology for real-time display on a portable computer and/or a local network. The system seems particularly attractive for individual monitoring at clinical facilities where high intensity and varying radiation fields may occur, as it enables the user to acknowledge and optimize the dose and dose rate values in real time for each procedure. Prior to its use, the system was characterized at the Metrology Laboratory of Ionizing Radiation of IST-LPSR aiming at the metrological characterization of the system in accordance with IEC 61526:2010 for metrological control purposes and to verify the technical specifications stated by the manufacturer. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Study of a selection of 10 historical types of dosemeter: variation of the response to Hp(10) with photon energy and geometry of exposure.

    PubMed

    Thierry-Chef, I; Pernicka, F; Marshall, M; Cardis, E; Andreo, P

    2002-01-01

    An international collaborative study of cancer risk among workers in the nuclear industry is tinder way to estimate direetly the cancer risk following protracted low-dose exposure to ionising radiation. An essential aspect of this study is the characterisation and quantification of errors in available dose estimates. One major source of errors is dosemeter response in workplace exposure conditions. Little information is available on energy and geometry response for most of the 124 different dosemeters used historically in participating facilities. Experiments were therefore set up to assess this. using 10 dosemeter types representative of those used over time. Results show that the largest errors were associated with the response of early dosemeters to low-energy photon radiation. Good response was found with modern dosemeters. even at low energy. These results are being used to estimate errors in the response for each dosemeter type, used in the participating facilities, so that these can be taken into account in the estimates of cancer risk.

  9. Comparison of Resonance Parameter Covariance Generation using CONRAD and SAMMY Computer Codes

    SciTech Connect

    Leal, Luiz C; De Saint Jean, C; Noguere, G

    2010-01-01

    Cross section evaluations in the resolved resonance region are based on formalisms derived from the R-matrix theory. As a result, the evaluations provide a set of resonance parameters that can be used to reproduce the experimental data reasonably well. The evaluated nuclear data are used in neutron transport calculations for the analysis and design of nuclear reactor systems, nuclear criticality safety analyses, etc. To achieve the desired accuracy on the nuclear system calculations, the questions frequently asked are how well the nuclear data are known and how the uncertainty in the nuclear data can be propagated into the final nuclear system results. There have been ongoing efforts at several research centers for generating data uncertainties in the resonance and high-energy regions. The biggest issue in relation to the covariance data is how good the calculated uncertainties are or whether the calculated uncertainties are in agreement with realistic uncertainties derived from an experimental nuclear system or nuclear benchmark. In this work an attempt is made to use two distinct and independently developed computer codes, CONRAD and SAMMY, to evaluate and generate covariance data in the resonance region. The verification study has been performed in support of the U.S. Nuclear Criticality Safety program (NCSP) as the NCSP is working to provide improved nuclear data files to support criticality safety analyses. The objective is to check the procedures and the methodologies used in the resonance region for covariance generation. The studies have been carried out using the 48Ti resolved resonance parameters.

  10. A STUDY ON THE UNCERTAINTY FOR THE ROUTINE DOSIMETRY SERVICE AT THE LEBANESE ATOMIC ENERGY COMMISSION USING HARSHAW 8814 DOSEMETERS.

    PubMed

    Rizk, C; Vanhavere, F

    2016-09-01

    The personal dosimetry service at the Lebanese Atomic Energy Commission uses Harshaw 8814 cards with LiF:Mg,Ti detectors. The dosemeters are read in a Harshaw 6600 TLD reader. In the process of accreditation for the ISO 17025 standard((1)), different influence factors are investigated and the uncertainty has been determined. The Individual Monitoring Service Laboratory-LAEC reads the dosemeters once it receives them from the customer, and new cards are immediately given for the next wearing period. The wearing period is 2 months. The dosemeter results are reported to the customers without background subtraction. Both Hp(10) and Hp(0.07) are reported. For this paper, only the uncertainty on Hp(10) will be focussed. The following factors are taken into account for the uncertainty: calibration factor, dosemeter homogeneity and repeatability, energy and angular dependence, non-linearity, temperature dependence, etc. Also the detection limit was determined. One of the important factors is the correction for fading. This fading correction depends on the procedure used such as storage temperatures, the time-temperature profile of the read-out, pre-heat and annealing conditions. Pre- and post-irradiation fading curves were measured for a storage period up to 182 d at room temperature (15-25°C). The resulting final combined standard uncertainty on the reported doses is of the order of 24 % for doses of ∼1 mSv. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. SCATTERED X-RAY ENERGY DATA FROM INTEGRATED MULTI-FILTER PERSONAL DOSEMETERS WORN BY INTERVENTIONAL RADIOLOGY STAFF.

    PubMed

    Mori, Hiroshige

    2016-11-01

    The accuracy and usability of scattered X-ray energy data obtained from multi-filter dosemeters were investigated by comparing the data with results obtained via Monte Carlo simulation. The energy data, which were read from integrated personal dosemeters used by interventional radiology (IR) staff in individual monitoring, were plotted against relative frequency and statistically assessed. The effective energy obtained from the multi-filter dosemeters was inversely proportional to detector size and lower than the results of the Monte Carlo simulation. All distributions of scattered X-ray energy to which the IR staff were exposed had only one peak value, which corresponded with the effective energy measured using a water phantom. For abdominal IR, there was a significant difference in the distributions between IR staff (p < 0.01). The results suggest that rectifying systematic errors resulting from oblique incidence of X-rays against the filters would make the energy data usable for optimisation of radiological protection. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Neutron personnel dosimetry

    SciTech Connect

    Griffith, R.V.

    1981-06-16

    The current state-of-the-art in neutron personnel dosimetry is reviewed. Topics covered include dosimetry needs and alternatives, current dosimetry approaches, personnel monitoring devices, calibration strategies, and future developments. (ACR)

  13. Vocabulary for Healthcare Personnel.

    ERIC Educational Resources Information Center

    Falagrady, Teresa

    Developed by educators from the Emily Griffith Opportunity School, this teacher's guide presents a course in health care vocabulary for secretaries, medical records personnel, laboratory assistants, shipping personnel, and patient relations personnel in health care facilities. The course, which should require 10-14 hours of instruction, contains…

  14. Personnel Department Automation.

    ERIC Educational Resources Information Center

    Wilkinson, David

    In 1989, the Austin Independent School District's Office of Research and Evaluation was directed to monitor the automation of personnel information and processes in the district's Department of Personnel. Earlier, a study committee appointed by the Superintendent during the 1988-89 school year identified issues related to Personnel Department…

  15. Performance of CVD diamond as an optically and thermally stimulated luminescence dosemeter.

    PubMed

    Preciado-Flores, S; Schreck, M; Meléndrez, R; Chernov, V; Bernal, R; Cruz-Vázquez, C; Cruz-Zaragoza, E; Barboza-Flores, M

    2006-01-01

    Diamond is a material with extreme physical properties. Its radiation hardness, chemical inertness and tissue equivalence qualify it as an ideal material for radiation dosimetry. In the present work, the optically stimulated luminescence (OSL) and thermoluminescence (TL) characteristics of a 10 microm thick CVD diamond (polycrystalline diamond films prepared by chemical vapor deposition) film were studied in order to test its performance as a beta radiation dosemeter. The TL response is composed of four main TL glow peaks; two of these are in the range of 150-200 degrees C and two additional peaks in the 250-400 degrees C temperature range. The integrated TL as a function of radiation dose is linear up to 100 Gy and increases with increasing dose exposure. The dose dependence of the integrated OSL exhibits a similar behavior. The observed OSL/TL behavior for the CVD diamond film clearly demonstrate its capability for applications in radiation dosimetry with special relevance in medical dosimetry owing to the diamond's intrinsic material properties.

  16. EURADOS INTERCOMPARISONS ON WHOLE-BODY DOSEMETERS FOR PHOTONS FROM 2008 TO 2014.

    PubMed

    Figel, Markus; Stadtmann, Hannes; Grimbergen, Tom W M; McWhan, Andrew; Romero, Ana M

    2016-09-01

    Starting in 2008 the European Dosimetry Group (EURADOS) has been performing international intercomparisons on photon whole-body dosemeters for individual monitoring services. These intercomparisons were organised (on a biannual basis) in 2008, 2010, 2012 and 2014, each time with a similar set-up but with small alterations in the subsequent irradiation plans. With an increasing number of participants and participating systems, this intercomparison action has become an important tool for individual monitoring services to test their whole-body dosimetry systems, compare their results with other services or systems and to improve the quality of their dosimetry. The paper presents and compares the results of these four intercomparisons and compares the dosimetric results for the participating system types. Major dosimetric problems of the individual monitoring services are identified, and trends in the dosimetric performance of the different systems are shown. This gives the opportunity to identify some dosimetry issues that should be improved by application of the monitoring services' quality assurance systems and QA procedures. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Study on the response of thermoluminescent dosemeters to synchrotron radiation: experimental method and Monte Carlo calculations.

    PubMed

    Bakshi, A K; Chatterjee, S; Palani Selvam, T; Dhabekar, B S

    2010-07-01

    In the present study, the energy dependence of response of some popular thermoluminescent dosemeters (TLDs) have been investigated such as LiF:Mg,Ti, LiF:Mg,Cu,P and CaSO(4):Dy to synchrotron radiation in the energy range of 10-34 keV. The study utilised experimental, Monte Carlo and analytical methods. The Monte Carlo calculations were based on the EGSnrc and FLUKA codes. The calculated energy response of all the TLDs using the EGSnrc and FLUKA codes shows excellent agreement with each other. The analytically calculated response shows good agreement with the Monte Carlo calculated response in the low-energy region. In the case of CaSO(4):Dy, the Monte Carlo-calculated energy response is smaller by a factor of 3 at all energies in comparison with the experimental response when polytetrafluoroethylene (PTFE) (75 % by wt) is included in the Monte Carlo calculations. When PTFE is ignored in the Monte Carlo calculations, the difference between the calculated and experimental response decreases (both responses are comparable >25 keV). For the LiF-based TLDs, the Monte Carlo-based response shows reasonable agreement with the experimental response.

  18. Portable TL dosemeter--ESD phantom combination for chest and lumbar spine radiography.

    PubMed

    Niittymäki, Henri; Hakanen, Arvi; Rautio, Simo; Järvinen, Hannu

    2008-01-01

    A thermoluminescence dosemeter (TLD)-entrance surface dose (ESD) phantom combination was calibrated in terms of air-kerma in IEC RQR X-ray radiation qualities between 50 and 150 kV. The ESD phantom was designed and constructed as a part of the work. With the combination, air-kermas were measured for four radiological examinations (two chest and two lumbar spine examinations in two hospitals), and converted to ESDa using Monte-Carlo calculated BSF data tabulated for different tube voltages, filtrations and beam diameters at 1 m distance. The results agreed with the ionisation-chamber measurements within the reported overall uncertainty of the TLD method. In the calibration, the ESD phantom can be replaced by the ISO water slab phantom unaffecting the reported overall uncertainty. Backscatter-related parameters for the ISO water slab phantom and the newly designed ESD phantom were determined for the IEC RQR qualities used in the secondary standard dosimetry laboratory of STUK at 1 m distance, including an approximate Hp(10)/Hp(0.07) ratio.

  19. Selection of the most appropriate two-dosemeter algorithm for estimating effective dose equivalent during maintenance periods in Korean nuclear power plants.

    PubMed

    Kim, Hee Geun; Kong, Tae Young

    2010-07-01

    The application of a two-dosemeter system with its algorithm, as well as a test of its use in an inhomogeneous high-radiation field, is described in this study. The goal was to improve the method for estimating the effective dose equivalent during maintenance periods at Korean Nuclear Power Plants (NPPs). The use of this method in Korean and international NPPs, including those NPPs in the USA and Canada, was also investigated. The algorithms used by the the American National Standards Institute, Lakshmanan, the National Council on Radiation Protection and Measurements (NCRP), the Electric Power Research Institute and Kim were extensively analysed as two-dosemeter algorithms. Their possible application to NPPs was evaluated using data for each algorithm from two-dosemeter results that were obtained from an inhomogeneous high-radiation field during maintenance periods at Korean NPPs. The NCRP algorithm (55:50) was selected as an optimal two-dosemeter algorithm for Korean NPPs by taking into account the field test results and the convenience of wearing two dosemeters.

  20. Chaplain Personnel Information Guide

    DTIC Science & Technology

    1991-04-15

    documnt may not be Mased for opem pisbiktao. si it hu been deajed by the appropiate miitay svice ot oervmnent qaeny. CHAPLAIN PERSONNEL INFORMATION GUIDE ...Include Security Classification) Chaplain Personnel Information Guide 12 PERSONAL AUTHOR(S) Chaplain (LTC) Jerry W. Black 13a. TYPE OF REPORT 13b...personnel information guide called the "Red Book." This guide contains information papers that are updated annually on subjects frequently discussed among the

  1. Energy and angular dependences of common types of personal dosemeters in the mirror of the First national intercomparison of individual dosimetric monitoring laboratories in Ukraine.

    PubMed

    Chumak, V; Deniachenko, N; Volosky, V

    2015-12-01

    In depth analysis of the results of the First National Intercomparison of individual dosimetry laboratories in Ukraine has revealed energy and angular responses of the most common types of personal dosemeters and dosi metric systems. Participating laboratories use 9 different types of dosimetric systems - automatic, semi automat ic and manual. If was found that energy dependences of the most common dosemeter types in Ukraine generally correspond to the literature data on respective TLD materials (LiF:Mg,Cu,P, LiF:Mg,TiandAl2O3:С), however, due to peculiarities of holders (filters) and dose algorithms, for some dosimetry systems the energy dependences can be improved (compensated). Angular dependences proved to be more pronounced: only two systems revealed weak dependence of response on the incident angle, for other systems at large angles (α=60°) dosemeters overestimate true dose values. V. Chumak, N. Deniachenko, V. Volosky.

  2. Sensitivity and fading of pMOS dosemeters irradiated with X-ray radiation doses from 1 to 100 cGy.

    PubMed

    Pejovic, Svetlana M; Pejovic, Milic M; Stojanov, Dragan; Ciraj-Bjelac, Olivera

    2016-01-01

    In this paper, the results of pMOS dosemeters sensitivity to X-ray radiation and 28-d fading at room temperature are presented. Two types of dosemeters were used, which differ in gate oxide layer thickness. The sensitivity of pMOS dosemeters with gate oxide layer thickness of 1 µm was followed in the dose intervals of 1 to 10 cGy and 10 to 100 cGy, whereas that of 400 nm was in the interval of 10 to 100 cGy. The sensitivity was characterised by the threshold voltage shift, which was determined as a function of absorbed radiation dose and time after irradiation. Linear dependence between threshold voltage shift and absorbed radiation dose was established, as well as that considerable fading occurs during the first few days after irradiation. The mechanisms responsible for threshold voltage shift during irradiation and latter annealing have been also discussed.

  3. Late Holocene diatom-based sea-surface temperature reconstruction from the Conrad Rise, Southern Ocean

    NASA Astrophysics Data System (ADS)

    Orme, Lisa; Mietinnen, Arto; Crosta, Xavier; Mohan, Rahul

    2017-04-01

    The Southern Ocean plays an important role in the global climate system. The temperature and sea ice extent alter the latitudinal temperature gradient of the Southern Ocean, which can be transferred to the atmosphere resulting in changes in the southern westerly winds. The temperature, sea ice and wind variations are also factors influencing Antarctic Bottom Water formation, which is a control on the strength of the Atlantic Meridional Overturning Circulation. Therefore conditions in the Southern Ocean may influence the climate in the northern and southern hemispheres. The Southern Ocean and North Atlantic were connected during the Last Glacial during Dansgaard-Oeschger events, when variations in ocean circulation caused a bipolar seesaw of temperatures. For the Holocene there is less evidence for a bipolar seesaw, although recent research shows concurrent, opposite trends in ocean circulation in the North Atlantic and in the Southern Ocean. Further reconstructions are required from the Southern Ocean in particular to enable greater understanding of how the temperature and sea ice varied during the Holocene. The OCTEL project (Ocean-sea-ice-atmosphere teleconnections between the Southern Ocean and North Atlantic during the Holocene) aims to investigate the ocean, atmosphere and sea-ice teleconnections for the Holocene using new, high resolution records from both the Southern Ocean and North Atlantic. We here present initial results from diatom analysis conducted on a sediment core from the Southern Ocean, sampled from the Conrad Rise (54˚ 16.04'S, 39˚ 45.98'W). The preliminary results highlight a dominance of diatom species Fragilariopsis kerguelensis and Thalassiosira lentiginosa, with lower abundances of Thalassiothrix antarctica and Thalassiosira gracilis among others, which suggests an open ocean setting close to the polar front. The diatom data will be converted to quantitative reconstructions of summer sea surface temperature and sea ice presence using the

  4. Evaluation of a personal and environmental dosemeter based on CR-39 track detectors in quasi-monoenergetic neutron fields.

    PubMed

    Caresana, M; Ferrarini, M; Parravicini, A; Sashala Naik, A

    2014-10-01

    In this paper, the evaluation of the dosimetric capability of a detector based on a CR-39 solid-state nuclear track detector coupled to a 1 cm thickness of PMMA radiator was made with the aim of understanding the applicability of this technique to personal and environmental neutron dosimetry. The dosemeter has been exposed to monoenergetic and quasi-monoenergetic neutron beams at PTB in Braunschweig, Germany and at Ithemba Laboratories, in Faure, South Africa, with peak energies ranging from 0.565 to 100 MeV. The results showed a response that is almost independent of the neutron energy in the whole energy range.

  5. Relative response of alanine dosemeters for high-energy electrons determined using a Fricke primary standard.

    PubMed

    Vörös, Sándor; Anton, Mathias; Boillat, Bénédicte

    2012-03-07

    A significant proportion of cancer patients is treated using MeV electron radiation. One of the measurement methods which is likely to furnish reliable dose values also under non-reference conditions is the dosimetry using alanine and read-out via electron spin resonance (ESR). The system has already proven to be suitable for QA purposes for modern radiotherapy involving megavoltage x-rays. In order to render the secondary standard measurement system of the Physikalisch-Technische Bundesanstalt based on alanine/ESR useable for dosimetry in radiotherapy, the dose-to-water (D(W)) response of the dosemeter needs to be known for relevant radiation qualities. For MeV electrons, the D(W) response was determined using the Fricke primary standard of the Swiss Federal Office of Metrology. Since there were no citable detailed publications on the Swiss primary standard available, this measurement system is described in some detail. The experimental results for the D(W) response are compared to results of Monte Carlo simulations which model in detail the beams furnished by the electron accelerator as well as the geometry of the detectors. The agreement between experiment and simulation is very good, as well as the agreement with results published by the National Research Council of Canada which are based on a different primary standard. No significant dependence of the D(W) response was found in the range between 6 and 20 MeV. It is therefore suggested to use a unique correction factor k(E) for alanine for all MeV qualities of k(E) = 1.012 ± 0.010.

  6. Projecting Personnel Needs.

    ERIC Educational Resources Information Center

    Kelly, Philip T.

    Increased reliance on personnel services is placing school districts' business operations in a no-win situation. This report evaluates methods of student population projection in relation to teacher costs. Educational costs reflect personnel costs in light of a decrease in the number of pupils being served. Increased enrollment projections create…

  7. Student Personnel "Educators."

    ERIC Educational Resources Information Center

    Knott, J. Eugene

    It is suggested that student personnel workers in higher education have comparable responsibilities to their academic counterparts as "educators" in a literal sense. Each contact with a student by personnel officers should be viewed as an opportunity for facilitating learning and growth. As such, a responsibility for being conversant with and open…

  8. Projecting Personnel Needs.

    ERIC Educational Resources Information Center

    Kelly, Philip T.

    Increased reliance on personnel services is placing school districts' business operations in a no-win situation. This report evaluates methods of student population projection in relation to teacher costs. Educational costs reflect personnel costs in light of a decrease in the number of pupils being served. Increased enrollment projections create…

  9. Personnel Management Institutes, 1975.

    ERIC Educational Resources Information Center

    Hinman, Stanley B., Jr., Comp.

    This publication is a compilation of five papers presented at the 1975 Personnel Management Institutes held by the New York State School Boards Association. Although the meeting was intended to provide useful information about personnel matters specifically for school board members and school administrators from New York, much of the content of…

  10. 75 FR 2821 - Personnel Records

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-19

    ...; ] OFFICE OF PERSONNEL MANAGEMENT 5 CFR Part 293 RIN 3206-AM05 Personnel Records AGENCY: U.S. Office of Personnel Management. ACTION: Proposed rule with request for comments. SUMMARY: The U.S. Office of Personnel Management (OPM) is proposing to amend the regulations governing disposition of Official Personnel Folders...

  11. Rigorous noise test and calibration check of strong-motion instrumentation at the Conrad Observatory in Austria.

    NASA Astrophysics Data System (ADS)

    Steiner, R.; Costa, G.; Lenhardt, W.; Horn, N.; Suhadolc, P.

    2012-04-01

    In the framework of the European InterregIV Italy/Austria project: "HAREIA - Historical and Recent Earthquakes in Italy and Austria" the Central Institute for Meteorology and Geodynamics (ZAMG) and Mathematic and Geosciences Department of University of Trieste (DMG) are upgrading the transfrontier seismic network of South-Eastern Alps with new 12 accelerometric stations to enhance the strong motion instrument density near the Austria/Italy border. Various public institutions of the provinces Alto Adige (Bolzano Province), Veneto (ARPAV) and Friuli Venezia Giulia (Regional Civil Defense) in Italy and in the Austrian province of Tyrol are involved in the project. The site selection was carried out to improve the present local network geometry thus meeting the needs of public Institutions in the involved regions. In Tyrol and Alto Adige some strategic buildings (hospitals and public buildings) have been selected, whereas in Veneto and Friuli Venezia Giulia the sites are in the free field, mainly located near villages. The instruments will be installed in an innovative box, designed by ZAMG, that provides electric and water isolation. The common choice regarding the instrument selection has been the new Kinemetrics Basalt ® accelerograph to guarantee homogeneity with the already installed instrumentation and compatibility with the software already in use at the different seismic institutions in the area. Prior to deployment the equipment was tested at the Conrad Observatory and a common set-up has been devised. The Conrad Observatory, seismically particularly quiet, permits to analyze both the sensor and the acquisition system noise. The instruments were connected to the network and the data sent in real-time to the ZAMG data center in Vienna and the DMG data center in Trieste. The data have been collected in the database and analyzed using signal processing modules PQLX and Matlab. The data analysis of the recordings at the ultra-quiet Conrad Observatory pointed out

  12. Sphenodiscus pleurisepta (Conrad, 1857) from the Maastrichtian La Tabla Formation in the Upper Magdalena Valley, Tolima, Colombia

    NASA Astrophysics Data System (ADS)

    Patarroyo, Pedro; Bengtson, Peter; Guerrero, Javier

    2010-11-01

    The La Tabla Formation is an important petroleum reservoir in the Upper Magdalena Valley of Colombia. It was deposited in regressive and lowstand systems tracts and comprises a succession of lower shoreface to coastal plain deposits. A section in the Talora Creek, near the village of Piedras, Department of Tolima, exposes 90 m of a progradational to aggradational succession composed of very fine sandstones to medium-grained pebble conglomerates, with abundant planktic and benthic foraminifers as well as bivalves and ammonites. A few well-preserved phragmocones of the ammonite Sphenodiscus pleurisepta ( Conrad, 1857), collected from a level 63 m above the base of the formation, are here described and the chronostratigraphic position of the species discussed. In the Western Interior Basin of North America, S. pleurisepta ranges from the upper lower Maastrichtian Baculites clinolobatus Zone through the upper Maastrichtian Jeletzkytes nebrascensis Zone. The present findings support previous datings of the La Tabla Formation as Maastrichtian on the basis of foraminifers.

  13. Generation of 238U Covariance Matrices by Using the Integral Data Assimilation Technique of the CONRAD Code

    NASA Astrophysics Data System (ADS)

    Privas, E.; Archier, P.; Bernard, D.; De Saint Jean, C.; Destouche, C.; Leconte, P.; Noguère, G.; Peneliau, Y.; Capote, R.

    2016-02-01

    A new IAEA Coordinated Research Project (CRP) aims to test, validate and improve the IRDF library. Among the isotopes of interest, the modelisation of the 238U capture and fission cross sections represents a challenging task. A new description of the 238U neutrons induced reactions in the fast energy range is within progress in the frame of an IAEA evaluation consortium. The Nuclear Data group of Cadarache participates in this effort utilizing the 238U spectral indices measurements and Post Irradiated Experiments (PIE) carried out in the fast reactors MASURCA (CEA Cadarache) and PHENIX (CEA Marcoule). Such a collection of experimental results provides reliable integral information on the (n,γ) and (n,f) cross sections. This paper presents the Integral Data Assimilation (IDA) technique of the CONRAD code used to propagate the uncertainties of the integral data on the 238U cross sections of interest for dosimetry applications.

  14. Measurement of the fluence response of the GSI neutron ball dosemeter in the energy range from thermal to 19 MeV.

    PubMed

    Fehrenbacher, G; Kozlova, E; Gutermuth, F; Radon, T; Schütz, R; Nolte, R; Böttger, R

    2007-01-01

    At high-energy particle accelerators, area monitoring needs to be performed in a wide range of neutron energies. In principle, neutrons occur from thermal energies up to the energy of the accelerated ions, which is for the present GSI (Gesellschaft für Schwerionenforschung) accelerator facility approximately 1-2 GeV per nucleon. There are no passive dosemeters available, which are designed for the use at high-energy accelerators. At GSI, a neutron dosemeter was developed, which is suitable for the measurement of high-energy neutron radiation by the insertion of a lead layer around Thermoluminescence (TL) detection elements (pairs of TL 600/700) at the centre of the dosemeter. The design of the sphere was derived from the construction of the extended range rem-counters for the measurement of ambient dose equivalent H(10). In this work, the dosemeter fluence response was measured in the quasi-monoenergetic neutron fields of the accelerator facility of the PTB in Braunschweig and in the thermal neutron field of the GKSS research reactor FRG-1 in Geesthacht. For the accelerator measurements, the reactions (7)Li(p,n)(7)Be, (3)H(p,n)(3)He and (2)H(d,n)(3)He were used to produce neutron fields with energy peaks between 144 keV and 19 MeV. The measured fluence responses are 27% too low for thermal energies and show an agreement with approximately 14% for the accelerator produced neutron fields related to the computed fluence responses (MCNP, FLUKA calculations). The measured as well as the computed fluence responses of the dosemeter are compared with the corresponding conversion coefficients.

  15. Vertical density contrast and mapping of basement, Conrad and Moho morphologies through 2D spectral analysis of gravity data in and around Odisha, India

    NASA Astrophysics Data System (ADS)

    Kumar, Arbind; S. Roy, P. N.; Das, L. K.

    2016-07-01

    Power spectrum analysis of Complete Bouguer Anomaly (CBA) map of Eastern Ghat Mobile Belt (EGMB) and its surroundings in India through Two Dimensional (2D) spectral analysis has provided estimates of the ensemble average depths for the density discontinuities which represent crustal inhomogeneities. The spectral analysis method has helped to estimate the depths of a perturbing body sources which are obtained from the negative slopes of the linear relationship between the logarithmic power spectrum and the wave-numbers of the gravity field. The detailed analysis reveals three horizontal discontinuities (i) Phanerozoic sediment thickness (ii) Basement depth and (iii) Conrad discontinuity. The average thickness of Phanerozoic sediments is estimated to be 3 km whereas depth of basement and Conrad discontinuity are at 7 km and 14.5 km respectively. Additionally Mohorovicic discontinuity also estimated at a depth of 32.8 km in the study region.

  16. Application of workplace correction factors to dosemeter results for the assessment of personal doses at nuclear facilities.

    PubMed

    Lindborg, L; Bolognese-Milsztajn, T; Boschung, M; Coeck, M; Curzio, G; d'Errico, F; Fiechtner, A; Hallfarth, D; Lievens, B; Lillhök, J-E; Lövefors-Daun, A; Lacoste, V; Luszik-Bhadra, M; Reginatto, M; Schuhmacher, H; Tanner, R; Vanhavere, F

    2007-01-01

    Ratios of H(p)(10) and H*(10) were determined with reference instruments in a number of workplace fields within the nuclear industry and used to derive workplace-specific correction factors. When commercial survey meter results together with these factors were applied to the results of the locally used personal dosemeters their results improved and became within 0.7 and 1.7 of the reference values or better depending on the response of the survey meter. A similar result was obtained when a correction was determined with a prototype reference instrument for H(p)(10) after adjustment of its response. Commercially available survey instruments both for photon and neutron H*(10) measurements agreed with the reference instruments in most cases to within 0.5-1.5. Those conclusions are derived from results reported within the EC supported EVIDOS contract.

  17. Improvement and calibration of a SSNT personal dosemeter and study of importance of albedo factor for dose calculation.

    PubMed

    Torkzadeh, F; Taheri, M

    2007-01-01

    The Neutriran albedo neutron dosemeter has been improved and calibrated for neutron personal dosimetry. The Monte Carlo code MCNP4b was used to calculate the thermal neutrons backscattered from the body (albedo factor). Backscattering from the wall, ceiling and floor in calibration room was considered also via simulation by MCNP4C. A semi automated counting system applying a high-resolution scanner was used for counting of tracks. An 241Am source was used to produce similar alpha particles from 10B (n,alpha)7Li reaction for the optimisation of scanner parameters to distinguish and separate the tracks in SSNTD, which lead to a better distinction between etched alpha tracks and, consequently, a higher linear region of dose characteristic.

  18. Personnel Retention Model Analysis.

    DTIC Science & Technology

    1980-01-01

    Of01 owee)V fOT public ,ei~ rd a;It _Ltributo su~ntd 11T. mgvOUTMu STATEMET (W10 sme inO" spr on.6 as. MI Afra Sme Bw Active Arumy. Personnel...S30. 1 * *0 .(4 s 5 *a j* IJ’) 531: IFR (JJFK)LTR(jjR ) GC To e02 532: RS ( ji j,,GF , 31 1 * SIJ’@jk K 533: *(J J F, )- K 534: 602 IF(ARS5J4

  19. A fibre optic scintillator dosemeter for absorbed dose measurements of low-energy X-ray-emitting brachytherapy sources.

    PubMed

    Sliski, Alan; Soares, Christopher; Mitch, Michael G

    2006-01-01

    A newly developed dosemeter using a 0.5 mm diameter x 0.5 mm thick cylindrical plastic scintillator coupled to the end of a fibre optic cable is capable of measuring the absorbed dose rate in water around low-activity, low-energy X-ray emitters typically used in prostate brachytherapy. Recent tests of this dosemeter showed that it is possible to measure the dose rate as a function of distance in water from 2 to 30 mm of a (103)Pd source of air-kerma strength 3.4 U (1 U = 1 microGy m(2) h(-1)), or 97 MBq (2.6 mCi) apparent activity, with good signal-to-noise ratio. The signal-to-noise ratio is only dependent on the integration time and background subtraction. The detector volume is enclosed in optically opaque, nearly water-equivalent materials so that there is no polar response other than that due to the shape of the scintillator volume chosen, in this case cylindrical. The absorbed dose rate very close to commercial brachytherapy sources can be mapped in an automated water phantom, providing a 3-D dose distribution with sub-millimeter spatial resolution. The sensitive volume of the detector is 0.5 mm from the end of the optically opaque waterproof housing, enabling measurements at very close distances to sources. The sensitive detector electronics allow the measurement of very low dose rates, as exist at centimeter distances from these sources. The detector is also applicable to mapping dose distributions from more complex source geometries such as eye applicators for treating macular degeneration.

  20. Effective dose assessment in the maxillofacial region using thermoluminescent (TLD) and metal oxide semiconductor field-effect transistor (MOSFET) dosemeters: a comparative study

    PubMed Central

    Schulze, D; Wolff, J; Rottke, D

    2014-01-01

    Objectives: The objective of this study was to compare the performance of metal oxide semiconductor field-effect transistor (MOSFET) technology dosemeters with thermoluminescent dosemeters (TLDs) (TLD 100; Thermo Fisher Scientific, Waltham, MA) in the maxillofacial area. Methods: Organ and effective dose measurements were performed using 40 TLD and 20 MOSFET dosemeters that were alternately placed in 20 different locations in 1 anthropomorphic RANDO® head phantom (the Phantom Laboratory, Salem, NY). The phantom was exposed to four different CBCT default maxillofacial protocols using small (4 × 5 cm) to full face (20 × 17 cm) fields of view (FOVs). Results: The TLD effective doses ranged between 7.0 and 158.0 µSv and the MOSFET doses between 6.1 and 175.0 µSv. The MOSFET and TLD effective doses acquired using four different (FOV) protocols were as follows: face maxillofacial (FOV 20 × 17 cm) (MOSFET, 83.4 µSv; TLD, 87.6 µSv; −5%); teeth, upper jaw (FOV, 8.5 × 5.0 cm) (MOSFET, 6.1 µSv; TLD, 7.0 µSv; −14%); tooth, mandible and left molar (FOV, 4 × 5 cm) (MOSFET, 10.3 µSv; TLD, 12.3 µSv; −16%) and teeth, both jaws (FOV, 10 × 10 cm) (MOSFET, 175 µSv; TLD, 158 µSv; +11%). The largest variation in organ and effective dose was recorded in the small FOV protocols. Conclusions: Taking into account the uncertainties of both measurement methods and the results of the statistical analysis, the effective doses acquired using MOSFET dosemeters were found to be in good agreement with those obtained using TLD dosemeters. The MOSFET dosemeters constitute a feasible alternative for TLDs for the effective dose assessment of CBCT devices in the maxillofacial region. PMID:25143020

  1. Effective dose assessment in the maxillofacial region using thermoluminescent (TLD) and metal oxide semiconductor field-effect transistor (MOSFET) dosemeters: a comparative study.

    PubMed

    Koivisto, J; Schulze, D; Wolff, J; Rottke, D

    2014-01-01

    The objective of this study was to compare the performance of metal oxide semiconductor field-effect transistor (MOSFET) technology dosemeters with thermoluminescent dosemeters (TLDs) (TLD 100; Thermo Fisher Scientific, Waltham, MA) in the maxillofacial area. Organ and effective dose measurements were performed using 40 TLD and 20 MOSFET dosemeters that were alternately placed in 20 different locations in 1 anthropomorphic RANDO(®) head phantom (the Phantom Laboratory, Salem, NY). The phantom was exposed to four different CBCT default maxillofacial protocols using small (4 × 5 cm) to full face (20 × 17 cm) fields of view (FOVs). The TLD effective doses ranged between 7.0 and 158.0 µSv and the MOSFET doses between 6.1 and 175.0 µSv. The MOSFET and TLD effective doses acquired using four different (FOV) protocols were as follows: face maxillofacial (FOV 20 × 17 cm) (MOSFET, 83.4 µSv; TLD, 87.6 µSv; -5%); teeth, upper jaw (FOV, 8.5 × 5.0 cm) (MOSFET, 6.1 µSv; TLD, 7.0 µSv; -14%); tooth, mandible and left molar (FOV, 4 × 5 cm) (MOSFET, 10.3 µSv; TLD, 12.3 µSv; -16%) and teeth, both jaws (FOV, 10 × 10 cm) (MOSFET, 175 µSv; TLD, 158 µSv; +11%). The largest variation in organ and effective dose was recorded in the small FOV protocols. Taking into account the uncertainties of both measurement methods and the results of the statistical analysis, the effective doses acquired using MOSFET dosemeters were found to be in good agreement with those obtained using TLD dosemeters. The MOSFET dosemeters constitute a feasible alternative for TLDs for the effective dose assessment of CBCT devices in the maxillofacial region.

  2. Personnel Management in Libraries.

    ERIC Educational Resources Information Center

    Rubin, Richard, Ed.

    1989-01-01

    Twelve articles discuss personnel management in libraries. Topics covered include building job commitment among employers, collective bargaining, entry-level recruitment, employee turnover, performance evaluation, managing resistance to change, training problems, productivity, employee stress, compensation systems, and the Allerton Park Institute.…

  3. Personnel Management Institutes 1974.

    ERIC Educational Resources Information Center

    Hinman, Stanley B., Jr.

    This report is a compilation of presentations made at the Personnel Management Institutes held by the New York State School Boards Association in the fall of 1974. Included are the following six presentations: "New Laws Affecting School Boards and School Administration," by Bernard T. McGivern; "How to Prepare for Tenure Hearings,…

  4. Personnel Management in Libraries.

    ERIC Educational Resources Information Center

    Rubin, Richard, Ed.

    1989-01-01

    Twelve articles discuss personnel management in libraries. Topics covered include building job commitment among employers, collective bargaining, entry-level recruitment, employee turnover, performance evaluation, managing resistance to change, training problems, productivity, employee stress, compensation systems, and the Allerton Park Institute.…

  5. Evaluating School Personnel Today.

    ERIC Educational Resources Information Center

    Poliakoff, Lorraine L.

    This document, an evaluation of school personnel, is based on a review of the literature on evaluation in the ERIC system. Emphasis is placed on the evaluation of school administrators, teacher evaluation by students, and the teacher's role in evaluation. A 23-item bibliography is included. (MJM)

  6. Personnel Management. Universities.

    ERIC Educational Resources Information Center

    Ohio Board of Regents, Columbus. Management Improvement Program.

    This manual is one of 10 completed in the Ohio Management Improvement Program (MIP) during the 1971-73 biennium. In this project, Ohio's 34 public universities and colleges, in an effort directed and staffed by the Ohio Board of Regents, have developed manuals of management practices, in this case, concerning personnel management. Emphasis in this…

  7. Training of Hydrometeorological Personnel.

    ERIC Educational Resources Information Center

    Hzmaljan, K. A.; And Others

    A working group of the Commission for Hydrometeorology has prepared this report to fill a need for detailed syllabi for instruction in hydrometeorology required by different levels of personnel. This situation has been brought about by the shortage or lack of national cadres of hydrologists in developing countries to undertake comprehensive water…

  8. Educational Personnel Evaluation.

    ERIC Educational Resources Information Center

    Thomas, M. Donald

    1985-01-01

    In this successful 10-year-old Salt Lake City, Utah, personnel evaluation program, every employee is entitled to and guaranteed the protection of due process--shortcomings are identified, assistance provided, and peers involved in employment decisions. Employees who cannot provide satisfactory service or learn the necessary skills are dismissed.…

  9. Migration of the Antarctic Circumpolar Current in the Late Neogene: reconstruction from sediment wave on the Conrad Rise, Indian Sector of the Southern Ocean

    NASA Astrophysics Data System (ADS)

    Oiwane, H.; Ikehara, M.; Suganuma, Y.; Nakamura, Y.; Nogi, Y.; Miura, H.; Sato, T.

    2012-12-01

    ACC is the largest and strongest ocean current in the world. It is important for the interoceanic exchange of water, exchange of gases to the atmosphere, and thermal isolation of the Antarctic continent. Fluctuation of the ACC has been reconstructed from several methods such as microfossils, anisotropy of magnetic susceptibilities, and statistical analysis of Ice-Rafted Debris. On the other hand, sediment waves are investigated and interpreted to reconstruct the fluctuation of the bottom- and contour currents. In this study, we tried reconstructing the ACC using sediment waves based on multidisciplinary survey on the Conrad Rise in the Indian sector of the Southern Ocean. The Conrad Rise is a topographic high that is elevated ca. 3000 m from the ocean floor. We conducted multibeam bathymetry, seismic reflection, and sediment coring on the southwestern slope of the rise. Seismic units on the Conrad Rise are divided into three units, A, B, and C in descending order. Unit A shows transparent to low amplitude with sediment wave structure. Sediment waves don't show systematic changes of its dimension and thickness. Sedimentary core showed that the surface sediment is composed of diatom ooze. Unit B shows higher amplitude than that of unit A, and shows planar, parallel configuration. Unit C has high-amplitude reflectors at its top and shows chaotic facies below. Based on morphological characteristics of the sediment waves, oceanographic setting of the Conrad Rise, and components of the surface sediment, it is most likely that the sedimentary structure and component of the Unit A is significantly constrained by the ACC. On the other hand, the Unit B shows planar configuration suggesting deposition without current effect. Additionally, higher amplitude suggests different component form that of the Unit A. These a series of evidence represent difference of sedimentary environment between units A and B, especially on the point of the influence of the ACC. Accordingly, onset

  10. Cytogenetic characterisation of the razor shells Ensis directus (Conrad, 1843) and E. minor (Chenu, 1843) (Mollusca: Bivalvia)

    NASA Astrophysics Data System (ADS)

    González-Tizón, Ana M.; Rojo, Verónica; Vierna, Joaquín; Jensen, K. Thomas; Egea, Emilie; Martínez-Lage, Andrés

    2013-03-01

    The European razor shell Ensis minor (Chenu 1843) and the American E. directus (Conrad 1843) have a diploid chromosome number of 38 and remarkable differences in their karyotypes: E. minor has four metacentric, one metacentric-submetacentric, five submetacentric, one subtelocentric and eight telocentric chromosome pairs, whereas E. directus has three metacentric, two metacentric-submetacentric, six submetacentric, six subtelocentric and two telocentric pairs. Fluorescent in situ hybridisation (FISH) using a major ribosomal DNA probe located the major ribosomal genes on one submetacentric chromosome pair in both species; FISH with a 5S ribosomal DNA (5S rDNA) probe rendered one chromosomal (weak) signal for E. minor and no signal for E. directus, supporting a more dispersed organisation of 5S rDNA compared to the major ribosomal genes. The vertebrate telomeric sequence (TTAGGG) n was located on both ends of each chromosome, and no interstitial signals were detected. In this work, a comparative karyological analysis was also performed between the four Ensis species analysed revealing that the three European species studied so far, namely E. minor, E. siliqua (Linné 1758) and E. magnus Schumacher 1817 show more similarities among them than compared to the American species E. directus. In addition, clear karyotype differences were found between the morphologically similar species E. minor and E. siliqua.

  11. Uncertainty evaluation of nuclear reaction model parameters using integral and microscopic measurements. Covariances evaluation with CONRAD code

    NASA Astrophysics Data System (ADS)

    de Saint Jean, C.; Habert, B.; Archier, P.; Noguere, G.; Bernard, D.; Tommasi, J.; Blaise, P.

    2010-10-01

    In the [eV;MeV] energy range, modelling of the neutron induced reactions are based on nuclear reaction models having parameters. Estimation of co-variances on cross sections or on nuclear reaction model parameters is a recurrent puzzle in nuclear data evaluation. Major breakthroughs were asked by nuclear reactor physicists to assess proper uncertainties to be used in applications. In this paper, mathematical methods developped in the CONRAD code[2] will be presented to explain the treatment of all type of uncertainties, including experimental ones (statistical and systematic) and propagate them to nuclear reaction model parameters or cross sections. Marginalization procedure will thus be exposed using analytical or Monte-Carlo solutions. Furthermore, one major drawback found by reactor physicist is the fact that integral or analytical experiments (reactor mock-up or simple integral experiment, e.g. ICSBEP, …) were not taken into account sufficiently soon in the evaluation process to remove discrepancies. In this paper, we will describe a mathematical framework to take into account properly this kind of information.

  12. Personnel Launch System definition

    NASA Astrophysics Data System (ADS)

    Piland, William M.; Talay, Theodore A.; Stone, Howard W.

    1990-10-01

    A lifting-body Personnel Launch System (PLS) is defined for assured manned access to space for future U.S. space missions. The reusable craft described is configured for reliable and safe operations, maintainability, affordability, and improved operability, and could reduce life-cycle costs associated with placing personnel into orbit. Flight simulations show the PLS to be a very flyable vehicle with very little control and propellant expenditure required during entry. The attention to crew safety has resulted in the design of a system that provides protection for the crew throughout the mission profile. However, a new operations philosophy for manned space vehicles must be adopted to fully achieve low-cost, manned earth-to-orbit transportation.

  13. Personnel Launch System definition

    NASA Technical Reports Server (NTRS)

    Piland, William M.; Talay, Theodore A.; Stone, Howard W.

    1990-01-01

    A lifting-body Personnel Launch System (PLS) is defined for assured manned access to space for future U.S. space missions. The reusable craft described is configured for reliable and safe operations, maintainability, affordability, and improved operability, and could reduce life-cycle costs associated with placing personnel into orbit. Flight simulations show the PLS to be a very flyable vehicle with very little control and propellant expenditure required during entry. The attention to crew safety has resulted in the design of a system that provides protection for the crew throughout the mission profile. However, a new operations philosophy for manned space vehicles must be adopted to fully achieve low-cost, manned earth-to-orbit transportation.

  14. PTSD among military personnel.

    PubMed

    Creamer, Mark; Wade, Darryl; Fletcher, Susan; Forbes, David

    2011-04-01

    Although symptoms characteristic of post-traumatic stress disorder (PTSD) have been noted in military personnel for many centuries, it was not until 1980 that the disorder was formally recognized and became the focus of legitimate study. This paper reviews our current state of knowledge regarding the prevalence and course of this complex condition in past and present members of the defence forces. Although rates vary across conflicts and countries, there is no doubt that PTSD affects substantial numbers of personnel and results in considerable impairment in functioning and quality of life. The paper goes on to discuss recent attempts to build resilience and to promote adjustment following deployment, noting that there is little evidence at this stage upon which to draw firm conclusions. Finally, effective treatment for PTSD is reviewed, with particular reference to the challenges posed by this population in a treatment setting.

  15. Military Personnel Law Deskbook

    DTIC Science & Technology

    2006-08-01

    February 2006). B. Purpose of the Physical Disability Evaluation System (PDES). 1. Personnel Management. a. Effective and Fit Military b. Quality ...discipline, or morale of troops on the base under his command.”). 3. Limitations. There must be some nexus between the authority sought and the effect on...preparing group for and steeling it to violent action). A-7 (2) Military Standard: Speech which undermines the effectiveness of response to command

  16. Energy response of GR-200A thermoluminescence dosemeters to 60Co and to monoenergetic synchrotron radiation in the energy range 28-40 keV.

    PubMed

    Emiro, F; Di Lillo, F; Mettivier, G; Fedon, C; Longo, R; Tromba, G; Russo, P

    2016-01-01

    The response of LiF:Mg,Cu,P thermoluminescence dosemeters (type GR-200A) to monoenergetic radiation of energy 28, 35, 38 and 40 keV was evaluated with respect to irradiation with a calibrated (60)Co gamma-ray source. High-precision measurements of the relative air kerma response performed at the SYRMEP beamline of the ELETTRA synchrotron radiation facility (Trieste, Italy) showed a significant deviation of the average response to low-energy X-rays from that to (60)Co, with an over-response from 6 % (at 28 keV) to 22 % (at 40 keV). These data are not consistent with literature data for these dosemeters, where model predictions gave deviation from unity of the relative air kerma response of about 10 %. The authors conclude for the need of additional determinations of the low-energy relative response of GR-200A dosemeters, covering a wider range of monoenergetic energies sampled at a fine energy step, as planned in future experiments by their group at the ELETTRA facility.

  17. MCNP SIMULATION OF THE HP(10) ENERGY RESPONSE OF A BRAZILIAN TLD ALBEDO NEUTRON INDIVIDUAL DOSEMETER, FROM THERMAL TO 20 MeV.

    PubMed

    Freitas, B M; Martins, M M; Pereira, W W; da Silva, A X; Mauricio, C L P

    2016-09-01

    The Brazilian Instituto de Radioproteção e Dosimetria (IRD) runs a neutron individual monitoring system with a home-made TLD albedo dosemeter. It has already been characterised and calibrated in some reference fields. However, the complete energy response of this dosemeter is not known, and the calibration factors for all monitored workplace neutron fields are difficult to be obtained experimentally. Therefore, to overcome such difficulties, Monte Carlo simulations have been used. This paper describes the simulation of the HP(10) neutron response of the IRD TLD albedo dosemeter using the MCNPX transport code, for energies from thermal to 20 MeV. The validation of the MCNPX modelling is done comparing the simulated results with the experimental measurements for ISO standard neutron fields of (241)Am-Be, (252)Cf, (241)Am-B and (252)Cf(D2O) and also for (241)Am-Be source moderated with paraffin and silicone. Bare (252)Cf are used for normalisation.

  18. Personnel Management: Two Year Colleges.

    ERIC Educational Resources Information Center

    Ohio Board of Regents, Columbus. Management Improvement Program.

    This document is one of five manuals designed to improve management practices in Ohio two-year colleges. A chapter on organizing for personnel management discusses basic personnel functions, roles and responsibilities of administrators, and the need for a central statewide office of personnel affairs. A chapter on planning, policies, and…

  19. Models of Personnel Needs Assessment.

    ERIC Educational Resources Information Center

    Mattson, Beverly

    This report presents samples of models and strategies for determining professional development needs of special education personnel. The following areas are covered: definitions of needs and the needs assessment process; personnel needs assessment regulations under the Comprehensive System of Personnel Development, the Individuals with…

  20. PERSONNEL NEUTRON DOSIMETER

    DOEpatents

    Fitzgerald, J.J.; Detwiler, C.G. Jr.

    1960-05-24

    A description is given of a personnel neutron dosimeter capable of indicating the complete spectrum of the neutron dose received as well as the dose for each neutron energy range therein. The device consists of three sets of indium foils supported in an aluminum case. The first set consists of three foils of indium, the second set consists of a similar set of indium foils sandwiched between layers of cadmium, whereas the third set is similar to the second set but is sandwiched between layers of polyethylene. By analysis of all the foils the neutron spectrum and the total dose from neutrons of all energy levels can be ascertained.

  1. Competent human research personnel.

    PubMed

    Arford, Patricia H; Knowles, Marilyn B; Sneed, Nancee V

    2008-12-01

    The process of conducting human research is highly regulated, rigorous, detailed oriented, potentially harmful, and, hopefully, beneficial. Health professionals learn how to critique, design, analyze, and apply human research but have minimal education in how to conduct human research. Successful completion of a 24-hour course was mandated for research support personnel to enhance the protection of human subjects, improve the integrity of data collected, and ensure cost-effective results. Routine audits demonstrated that the course substantially improved the documentation of the informed consent process, source documentation, protocol adherence, and regulatory compliance.

  2. Development of a technique for improving coefficient of variation of CaSO4:Dy teflon-based TLD personnel monitoring system in low-dose region.

    PubMed

    Pradhan, S M; Sneha, C; Sahai, M K; Chougaonkar, M P; Babu, D A R

    2015-12-01

    In view of the importance of zero-dose background (null signal) in influencing the coefficient of variation in low-dose region, a technique for the estimation of the same from composite (gross) signal is developed for CaSO4:Dy-based personnel monitoring system being used in India. The technique is based on simple analysis of glow curves (GCs) of unexposed and exposed dosemeters, evolution of trend/model for the zero-dose curves, generation of simulation protocol for individual zero-dose curves, establishment of characteristics of GCs of exposed dosemeters and finally preparation of an algorithm to segregate the components from composite signal. The technique offers the separation of real-time background and gives superior results over other method of approximation of the background. The results also prove efficiency of the empirical trending and simulation protocol of background GCs. The proposed technique can be implemented in routine monitoring without any extra man hours and reader time.

  3. On the use of LiF:Mg,Ti thermoluminescence dosemeters in space--a critical review.

    PubMed

    Horowitz, Y S; Satinger, D; Fuks, E; Oster, L; Podpalov, L

    2003-01-01

    The use of LiF:Mg,Ti thermoluminescence dosemeters (TLDs) in space radiation fields is reviewed. It is demonstrated in the context of modified track structure theory and microdosimetric track structure theory that there is no unique correlation between the relative thermoluminescence (TL) efficiency of heavy charged particles, neutrons of all energies and linear energy transfer (LET). Many experimental measurements dating back more than two decades also demonstrate the multivalued, non-universal, relationship between relative TL efficiency and LET. It is further demonstrated that the relative intensities of the dosimetric peaks and especially the high-temperature structure are dependent on a large number of variables, some controllable, some not. It is concluded that TL techniques employing the concept of LET (e.g. measurement of total dose, the high-temperature ratio (HTR) methods and other combinations of the relative TL efficiency of the various peaks used to estimate average Q or simulate Q-LET relationships) should be regarded as lacking a sound theoretical basis, highly prone to error and, as well, lack of reproducibility/universality due to the absence of a standardised experimental protocol essential to reliable experimental methodology.

  4. Numerical simulations for diamond sensors as real-time X-ray skin dosemeters; comparison to silicon

    NASA Astrophysics Data System (ADS)

    Jung, M.; Morel, J.; Siffert, P.

    2008-03-01

    Simulation results from Monte Carlo codes developed in our laboratory are used to analyze and improve detector responses against unknown high flux X-ray spectra exposures, as encountered in medicine. The algorithms are applied to diamond and silicon based dosemeters studies. The simulations are focused on real-time skin dosimetry for X-ray energies between 10 and 200 keV. The detector response is simulated as an induced collected charge under high fluence irradiation, to control patient injury. The dose equivalent response at 0.07 mm skin depth is calculated for a large set of diamond sensors. Their sensitivity, accuracy and angular response dispersion are presented. The quasi-tissue equivalent property of the diamond material allows maximum response uncertainties lower than 10% at least up to 75∘ opening incidences. For such monitors the amount of collected charges shows an asymptotic maximum limit near 80 nC Sv-1 per mm 3 sensor interaction volume. These performances are discussed, and compared to those of silicon diodes.

  5. Organ dose and effective dose estimation in paediatric chest radiographic examinations by using pin silicon photodiode dosemeters.

    PubMed

    Kawasaki, Toshio; Aoyama, Takahiko; Yamauchi-Kawaura, Chiyo; Fujii, Keisuke; Koyama, Shuji

    2013-01-01

    Organ and effective doses during paediatric chest radiographic examination were investigated for various tube voltages between 60 and 110 kV at a constant milliampere-second value and focus-to-film distance by using an in-phantom dose measuring system and a Monte Carlo (MC) simulation software (PCXMC), where the former was composed of 32 photodiode dosemeters embedded in various tissue and organ sites within a 6-y-old child anthropomorphic phantom. Lung doses obtained ranged from 0.010 to 0.066 mGy and effective doses from 0.004 to 0.025 mSv, where these doses varied by a factor of 6 with the change in the tube voltage. Effective doses obtained using the MC simulation software agreed with those obtained using the dose measuring system within 23 %, revealing the usefulness of PCXMC software for evaluating effective doses. The present study would provide helpful dose data for the selection of technical parameters in paediatric chest radiography in Japan.

  6. Assessment of effective radiation dose of an extremity CBCT, MSCT and conventional X ray for knee area using MOSFET dosemeters.

    PubMed

    Koivisto, Juha; Kiljunen, Timo; Wolff, Jan; Kortesniemi, Mika

    2013-12-01

    The objective of this study was to assess and compare the organ and effective doses in the knee area resulting from different commercially available multislice computed tomography devices (MSCT), one cone beam computed tomography device (CBCT) and one conventional X-ray radiography device using MOSFET dosemeters and an anthropomorphic RANDO knee phantom. Measurements of the MSCT devices resulted in effective doses ranging between 27 and 48 µSv. The CBCT measurements resulted in an effective dose of 12.6 µSv. The effective doses attained using the conventional radiography device were 1.8 µSv for lateral and 1.2 µSv for anterior-posterior projections. The effective dose resulting from conventional radiography was considerably lower than those recorded for the CBCT and MSCT devices. The MSCT effective dose results were two to four times higher than those measured on the CBCT device. This study demonstrates that CBCT can be regarded as a potential low-dose 3D imaging technique for knee examinations.

  7. Personnel electronic neutron dosimeter

    DOEpatents

    Falk, R.B.; Tyree, W.H.

    1982-03-03

    A personnel electronic dosimeter includes a neutron-proton and neutron-alpha converter for providing an electrical signal having a magnitude proportional to the energy of a detected proton or alpha particle produced from the converter, a pulse generator circuit for generating a pulse having a duration controlled by the weighed effect of the amplitude of the electrical signal, an oscillator enabled by the pulse for generating a train of clock pulses for a time dependent upon the pulse length, a counter for counting the clock pulses, and an indicator for providing a direct reading and aural alarm when the count indicates that the wearer has been exposed to a selected level of neutron dose equivalent.

  8. Personnel electronic neutron dosimeter

    DOEpatents

    Falk, Roger B.; Tyree, William H.

    1984-12-18

    A personnel electronic dosimeter includes a neutron-proton and neutron-alpha converter for providing an electrical signal having a magnitude proportional to the energy of a detected proton or alpha particle produced from the converter, a pulse generator circuit for generating a pulse having a duration controlled by the weighed effect of the amplitude of the electrical signal, an oscillator enabled by the pulse for generating a train of clock pulses for a time dependent upon the pulse length, a counter for counting the clock pulses, and an indicator for providing a direct reading and aural alarm when the count indicates that the wearer has been exposed to a selected level of neutron dose equivalent.

  9. Personnel emergency carrier vehicle

    NASA Technical Reports Server (NTRS)

    Owens, Lester J. (Inventor); Fedor, Otto H. (Inventor)

    1987-01-01

    A personnel emergency carrier vehicle is disclosed which includes a vehicle frame supported on steerable front wheels and driven rear wheels. A supply of breathing air is connected to quick connect face mask coupling and umbilical cord couplings for supplying breathing air to an injured worker or attendant either with or without a self-contained atmospheric protection suit for protection against hazardous gases at an accident site. A non-sparking hydraulic motion is utilized to drive the vehicle and suitable direction and throttling controls are provided for controlling the delivery of a hydraulic driving fluid from a pressurized hydraulic fluid accumulator. A steering axis is steerable through a handle to steer the front wheels through a linkage assembly.

  10. Advantage of 3D volumetric dosemeter in delivery quality assurance of dynamic arc therapy: comparison of pencil beam and Monte Carlo calculations

    PubMed Central

    Shin, H-J; Song, J H; Jung, J-Y; Kwak, Y-K; Kay, C S; Kang, Y-N; Choi, B O; Jang, H S

    2013-01-01

    Objective: To evaluate the accuracy of pencil beam calculation (PBC) and Monte Carlo calculation (MCC) for dynamic arc therapy (DAT) in a cylindrically shaped homogenous phantom, by comparing the two plans with an ion chamber, a film and a three-dimensional (3D) volumetric dosemeter. Methods: For this study, an in-house phantom was constructed, and the PBC and MCC plans for DAT were performed using iPlan® RT (BrainLAB®, Heimstetten, Germany). The A16 micro ion chamber (Standard Imaging, Middleton, WI), Gafchromic® EBT2 film (International Specialty Products, Wayne, NJ) and ArcCHECK™ (Sun Nuclear, Melbourne, FL) were used for measurements. For comparison with each plan, two-dimensional (2D) and 3D gamma analyses were performed using 3%/3 mm and 2%/2 mm criteria. Results: The difference between the PBC and MCC plans using 2D and 3D gamma analyses was found to be 7.85% and 28.8%, respectively. The ion chamber and 2D dose distribution measurements did not exhibit this difference revealed by the comparison between the PBC and MCC plans. However, the 3D assessment showed a significant difference between the PBC and MCC (62.7% for PBC vs 93.4% for MCC, p = 0.034). Conclusion: Evaluation using a 3D volumetric dosemeter can be clinically useful for delivery quality assurance (QA), and the MCC should be used to achieve the most reliable dose calculation for DAT. Advances in knowledge: (1) The DAT plan calculated using the PBC has a limitation in the calculation methods, and a 3D volumetric dosemeter was found to be an adequate tool for delivery QA of DAT. (2) The MCC was superior to PBC in terms of the accuracy in dose calculation for DAT even in the homogenous condition. PMID:24234583

  11. Physical Assault of School Personnel

    ERIC Educational Resources Information Center

    Kajs, Lawrence T.; Schumacher, Gary; Vital, Cheryl A.

    2014-01-01

    Physical assault against school personnel is a serious problem, although not highly publicized. This workplace violence can result in debilitating injury to school employees along with major monetary costs. This article looks at legal issues that address physical assault against school personnel as well as the roles professional associations have…

  12. Personnel Practices for Small Colleges.

    ERIC Educational Resources Information Center

    Bouchard, Ronald A.

    Personnel administration in higher education is the focus of this "hands-on, how-to-do-it" guide that provides fundamental materials for developing and maintaining a sound personnel program. Part One (Employment) examines government regulations, employee recruitment and selection, pre-employment inquiries and screening, post-employment process,…

  13. The Dartnell Personnel Director's Handbook.

    ERIC Educational Resources Information Center

    Scheer, Wilbert E.

    This handbook for personnel directors is designed to help improve the acquisition, selection, development, welfare, and general administration and control of business and industrial employees. Overall objectives and functions of personnel management are considered first. Part 2 (Employment) stresses advance planning; recruiting and interviewing;…

  14. Readings in Professional Personnel Assessment.

    ERIC Educational Resources Information Center

    International Personnel Management Association, Washington, DC.

    Thirteen papers are presented that discuss issues in public personnel decision making, specifically in the area of personnel selection. After an introduction by James P. Springer, the following papers are presented: (1) "History of Employment Testing" (Matthew Hale); (2) "Job Families: A Review and Discussion of Their Implications for Personnel…

  15. SCOPE OF PUPIL PERSONNEL SERVICES.

    ERIC Educational Resources Information Center

    ECKERSON, LOUISE OMWAKE; SMITH, HYRUM M.

    PART I OF THIS PAMPHLET DESCRIBES THE INTERPROFESSIONAL RESEARCH COMMISSION ON PUPIL PERSONNEL SERVICES, WHICH WAS STARTED IN 1962 BY THE OFFICE OF EDUCATION AND FINANCED BY THE NATIONAL INSTITUTE OF MENTAL HEALTH FOR A 5-YEAR PROGRAM. THE REST OF THE PAMPHLET DEALS WITH STATISTICS AND SPECIFIC PUPIL PERSONNEL SERVICES. OF THE 60,000…

  16. College Student Personnel Graduate Placement

    ERIC Educational Resources Information Center

    Packwood, William

    1976-01-01

    ACPA's Commission XII surveyed 103 college student personnel training institutions regarding their graduate placement. Graduates were identified according to degree, sex, and race. Percentages of graduates placed, areas within the college student personnel field, types of institutions, and areas of the country were computed. The discussion…

  17. Physical Assault of School Personnel

    ERIC Educational Resources Information Center

    Kajs, Lawrence T.; Schumacher, Gary; Vital, Cheryl A.

    2014-01-01

    Physical assault against school personnel is a serious problem, although not highly publicized. This workplace violence can result in debilitating injury to school employees along with major monetary costs. This article looks at legal issues that address physical assault against school personnel as well as the roles professional associations have…

  18. A novel fast neutron dosemeter based on fission chambers. Part I: Principles of operation and theoretical response in neutron therapy radiation fields.

    PubMed

    Porter, D; Lawson, R C; Hannan, W J

    1975-05-01

    A novel method is proposed of accurately measuring fast neutron doses of interest in radiotherapy. The technique, which utilizes calculated neutron fluence-to-kerma conversion factors, is based upon the combination of measurements with calibrated neptunium-237 and uranium-238 pulse fission chambers to obtain a response which matches the variation of kerma with neutron energy. The theoretical performance of a practical instrument has been assessed for a variety of neutron spectra to evaluate the spectrum dependence of the dosemeter. The overall systematic uncertainty using this absolute method of determining the neutron dose under charged particle equilibrium conditions is comparable to that encountered with ionization chamber techniques.

  19. Absorbed dose measurements of a handheld 50 kVP X-ray source in water with thermoluminescence dosemeters.

    PubMed

    Soares, Christopher; Drupieski, Chris; Wingert, Brian; Pritchett, Garey; Pagonis, Vasilis; O'Brien, Michelle; Sliski, Alan; Bilski, Pawel; Olko, Pawel

    2006-01-01

    Absorbed dose rate measurements of a 50 kV(p) handheld X-ray probe source in a water phantom are described. The X-ray generator is capable of currents of up to 40 microA, and is designed for cranial brachytherapy and intraoperative applications with applicators. The measurements were performed in a computer-controlled water phantom in which both the source and the detectors are mounted. Two different LiF thermoluminescence dosemeter (TLD) phosphors were employed for the measurements, MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P). Two small ionisation chambers (0.02 and 0.0053 cm(3)) were also employed. The TLDs and chambers were positioned in watertight mounts made of water-equivalent plastic. The chambers were calibrated in terms of air-kerma rate, and conventional protocols were used to convert the measurements to absorbed dose rate. The TLDs were calibrated at National Institute of Standards and Technology (NIST) in terms of absorbed dose rate using a (60)Co teletherapy beam and narrow-spectrum X-ray beams. For the latter, absorbed dose was inferred from air-kerma rate using calculated air-kerma-to-dose conversion factors. The reference points of the various detectors were taken as the center of the TLD volumes and the entrance windows of the ionisation chambers. Measurements were made at distances of 3-45 mm from the detector reference point to the source center. In addition, energy dependence of response measurements of the TLDs used was made using NIST reference narrow spectrum X-ray beams. Measurement results showed reasonable agreement in absorbed dose rate determined from the energy dependence corrected TLD readings and from the ionisation chambers. Volume averaging effects of the TLDs at very close distances to the source were also evident.

  20. The Personnel Launch System

    NASA Technical Reports Server (NTRS)

    Piland, William M.; Talay, Theodore A.; Stone, Howard W.

    1990-01-01

    NASA has begun to study candidate vehicles for manned access to space in support of the Space Station or other future missions requiring on-demand transportation of people to and from earth orbit. One such system, which would be used to complement the present Shuttle or an upgraded version, is the Personnel Launch System (PLS), which is envisioned as a reusable priority vehicle to place people and small payloads into orbit using an experimental launch vehicle. The design of the PLS is based on a Space Station crew changeout requirement whereby eight passengers and two crew members are flown to the station and a like number are returned within a 72 hour mission duration. Experimental and computational aerothermodynamic heating studies have been conducted using a new two-color thermographic technique that involved coating the model with a phosphor that radiates at varying color intensities as a function of temperature when illuminated with UV light. A full-scale model, the HL-20, has been produced and will be used for man-machine research. Three launch vehicle concepts are being considered, a Titan IV, the Advanced Launch System, and a Shuttle equipped with liquid rocket boosters.

  1. Expert systems for personnel assignment

    SciTech Connect

    Hardee, J.L.; Liepins, G.

    1986-01-01

    In order to reduce stress on assignment personnel (detailers) and ensure maximum fairness and consistency in the Navy's personnel assignment process, The Navy Military Personnel Command (NMPC) has begun to explore the potential use of expert systems to supplement current manual and computerized distribution methods. The Detailer's Assistant expert system is being developed to improve the detailers' ability to satisfy the needs of their constituents and Navy management. An initial prototype of the Detailer's Assistant is now being evaluated. Numerous upgrades and extensions should lead to an operational system in the near future. Further development to a production system will involve additional research in machine learning, intelligent database methods, and cooperating expert systems.

  2. Energy and directional response for the Harshaw dosemeter holders 8814 and 8891, and its effect on the appropriate radiation qualities for absolute calibration.

    PubMed

    Børretzen, I; Wøhni, T

    2003-01-01

    The personal dosimetry laboratory at the Norwegian radiation protection authority utilises a two-element dosemeter card for measuring Hp(10) and Hp(0.07), in a Harshaw dosemeter holder type 8814. Energy and directional responses for photons and betas for this holder have been assessed, as well as for the new Harshaw holder type 8891. The energy response characteristics for the 12-1250 keV photon energy range, in terms of TL output per unit Hp(10) and Hp(0.07) have been evaluated. The maximum over-response to under-response ratio for the Hp(10) element was found to be 1.46 for the new type 8891 holder, as compared to 1.55 for the older type 8814. The new holder also displays a more favourable directional response for this element. For the Hp(0.07) element, no significant differences with regard to energy or directional responses were found. Selecting radiation energy for absolute calibration of the Hp(10) and Hp(0.07) elements are discussed.

  3. Application of low-cost Gallium Arsenide light-emitting-diodes as kerma dosemeter and fluence monitor for high-energy neutrons.

    PubMed

    Mukherjee, B; Simrock, S; Khachan, J; Rybka, D; Romaniuk, R

    2007-01-01

    Displacement damage (DD) caused by fast neutrons in unbiased Gallium Arsenide (GaAs) light emitting diodes (LED) resulted in a reduction of the light output. On the other hand, a similar type of LED irradiated with gamma rays from a (60)Co source up to a dose level in excess of 1.0 kGy (1.0 x 10(5) rad) was found to show no significant drop of the light emission. This phenomenon was used to develop a low cost passive fluence monitor and kinetic energy released per unit mass dosemeter for accelerator-produced neutrons. These LED-dosemeters were used to assess the integrated fluence of photoneutrons, which were contaminated with a strong bremsstrahlung gamma-background generated by the 730 MeV superconducting electron linac driving the free electron laser in Hamburg (FLASH) at Deutsches Elektronen-Synchrotron. The applications of GaAs LED as a routine neutron fluence monitor and DD precursor for the electronic components located in high-energy accelerator environment are highlighted.

  4. Studies on automatic hot gas reader used in the countrywide personnel monitoring programme.

    PubMed

    Kumar, Munish; Alagu Raja, E; Prasad, L C; Popli, K L; Kher, R K; Bhatt, B C

    2005-01-01

    In India, approximately 58,000 radiation workers are monitored using locally made CaSO4:Dy teflon embedded thermoluminescence dosemeter (TLD) badge system. The automatic hot gas readers developed locally are also used in TL measurements. The hot gas reader system has many advantages over the manual readers used previously and has completely replaced the manual reader system in all TLD personnel monitoring units in India. In the present study, the new reader system is studied and a theoretical attempt has been made to interpret the experimentally obtained results. The glow curves are generated theoretically and are also plotted experimentally. It has been found that the heat capacity of the heating gas, which is responsible for the transfer of heat, has a role in deciding the position of peak and is verified experimentally using different gas flow rates of nitrogen and argon as heating gases in the reader. The theoretical study may also be helpful in fitting the experimentally obtained glow curves and, therefore, the elimination of unwanted non-radiation-induced contributions, such as dark current, electronic spikes, light leakage and triboluminescence that generally distort the glow curve shape, can be achieved.

  5. Health Hazards of Hospital Personnel

    PubMed Central

    Clever, Linda Hawes

    1981-01-01

    Health care workers historically have faced serious health problems, such as exposure to patients with tuberculosis. For hospital personnel today, a number of hazards exist. These range from toxic substance exposure to safety hazards presented by patients themselves. PMID:7281652

  6. Outplacement: An Established Personnel Function

    ERIC Educational Resources Information Center

    Scherba, John

    1978-01-01

    Every professional personnel department has the basic skills to provide at least minimum outplacement services such as resume preparation, resume typing and reproduction, counseling, and suggestions of job leads. (Author)

  7. Electrostatic forces for personnel restraints

    NASA Technical Reports Server (NTRS)

    Ashby, N.; Ciciora, J.; Gardner, R.; Porter, K.

    1977-01-01

    The feasibility of utilizing electrostatic forces for personnel retention devices on exterior spacecraft surfaces was analyzed. The investigation covered: (1) determination of the state of the art; (2) analysis of potential adhesion surfaces; (3) safety considerations for personnel; (4) electromagnetic force field determination and its effect on spacecraft instrumentation; and (5) proposed advances to current technology based on documentation review, analyses, and experimental test data.

  8. [Morbidity in draft military personnel].

    PubMed

    Mukhametzhanov, A M; Smagulov, N K

    2015-01-01

    Military service activity appeared to influence health state of military personnel. Body strain at initial stages of the service, connected with stress situation, affects general body resistance and manifests in higher general morbidity level with transitory disablement that decreases with adaptation. Based on normalized intensity parameters, the equation enables to ease a procedure of evaluation and forecast of transitory disablement morbidity in draft military personnel.

  9. 10 CFR 1016.25 - Protective personnel.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Protective personnel. 1016.25 Section 1016.25 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) SAFEGUARDING OF RESTRICTED DATA Physical Security § 1016.25 Protective personnel. Whenever protective personnel are required by § 1016.23, such protective personnel...

  10. 21 CFR 21.32 - Personnel records.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... consult system notices applicable to the agency's personnel records that are published by the Office of... the procedures in § 21.33 and subparts D through F of this part, govern systems of personnel records... Personnel Management, i.e., systems that: (i) The Office of Personnel Management maintains. (ii)...

  11. Advances in personnel neutron dosimetry

    SciTech Connect

    Vallario, E.; Faust, L.

    1983-07-01

    A program to assess current personnel neutron dosimeter capabilities and to develop improved personnel neutron dosimeters examines the two types of passive dosimeters in use at DOE facilities: NTA film and TLD-albedo dosimeters. Two new neutron dosimeters under development to overcome some of their problems are combination/track-etch dosimeters and pocket rem-meters. The DOE program is investigating new materials and improved manufacturing processes using the CR-39 polymer and that is nearly free of surface defects. 1 figure.

  12. Evaluation of the performance of two LiF:Mg,Ti and LiF:Mg,Cu,P dosemeters for extremity monitoring.

    PubMed

    Freire, L C; Pereira, M F; Calado, A M; Santos, L M; Cardoso, J V; Alves, J G

    2011-03-01

    In this paper, the results aimed at assessing the performance of two varieties of LiF detectors (LiF:Mg,Ti and LiF:Mg,Cu,P) in photon fields relatively to reproducibility, detection threshold and angular dependence as defined in the ISO 12794 standard are presented. The fading properties and the limit of detection were also investigated for both materials. The results suggest that both LiF varieties are well suited for extremity monitoring. However, better fading properties of LiF:Mg,Cu,P when compared with LiF:Mg,Ti, combined with previous results relatively to energy dependence suggests that LiF:Mg,Cu,P dosemeters are better suited for extremity monitoring.

  13. Technical Performance of the Luxel Al2O3:C Optically Stimulated Luminescence Dosemeter Element at Radiation Oncology and Nuclear Accident Dose Levels

    SciTech Connect

    Miller, Steven D.; Murphy, Mark K.

    2006-12-12

    The dose ranges typical for radiation oncology and nuclear accident dosimetry are on the order of 2?70 Gy and 0.1?5 Gy, respectively. In terms of solid-state passive dosimetry; thermoluminescent (TL) materials historically have been used extensively for these two applications, with silver-halide, leuco-dye, and BaFBr:Eu-based films being used on a more limited basis than TL for radiation oncology. This present work provides results on the performance of a film based on an aluminum oxide, Al2O3:C, for these dosimetry applications, using the optically-stimulated luminescence (OSL) readout method. There have been few investigations of Al2O3:C performance at radiation oncology and nuclear accident dose levels, and these have included minimal dosimetric and environmental effects information. Based on investigations already published, the authors of this present study determined that overall improvements over film and TLDs for this Al2O3:C OSL technology at radiation oncology and nuclear accident dose levels may include (1) a more tissue-equivalent response to photons compared to X-ray film, (2) higher sensitivity, (3) ability to reread dosemeters, and (4) diagnostic capability using small-area imaging. The results of the present investigation indicate that additional favorable performance characteristics for the Al2O3:C dosemeter are a wide dynamic range(0.001 to 100 Gy), a response insensitive to temperature and moisture over a wide range, negligible dose rate dependence, and minimal change in post-irradiation response. As a radiation detection medium, this OSL phosphor offers an assortment of dosimetry properties that will permit it to compete with current radiation detection technologies such as silver-halide, leuco-dye, and photostimulable-phosphor based films, as well as TLDs.

  14. Technical performance of the Luxel Al(2)O(3):C optically stimulated luminescence dosemeter element at radiation oncology and nuclear accident dose levels.

    PubMed

    Miller, Steven D; Murphy, Mark K

    2007-01-01

    The dose ranges typical for radiation oncology and nuclear accident dosimetry are on the order of 2-70 Gy and 0.1-5 Gy, respectively. In terms of solid-state passive dosimetry, thermoluminescent (TL) materials historically have been used extensively for these two applications, with silver-halide, leuco-dye and BaFBr:Eu-based films being used on a more limited basis than TL for radiation oncology. This present work provides results on the performance of a film based on an aluminum oxide, Al(2)O(3):C, for these dosimetry applications, using the optically stimulated luminescence (OSL) readout method. There have been few investigations of Al(2)O(3):C performance at radiation oncology and nuclear accident dose levels, and these have included minimal dosimetric and environmental effects information. Based on investigations already published, the authors of this present study determined that overall improvements over film and TLDs for this Al(2)O(3):C OSL technology at radiation oncology and nuclear accident dose levels may include (1) a more tissue-equivalent response to photons compared to X-ray film, (2) higher sensitivity, (3) ability to reread dosemeters and (4) diagnostic capability using small-area imaging. The results of the present investigation indicate that additional favourable performance characteristics for the Al(2)O(3):C dosemeter are a wide dynamic range (0.001-100 Gy), a response insensitive to temperature and moisture over a wide range, negligible dose rate dependence, and minimal change in post-irradiation response. As a radiation detection medium, this OSL phosphor offers an assortment of dosimetry properties that will permit it to compete with current radiation detection technologies such as silver-halide, leuco-dye and photostimulable-phosphor-based films, as well as TLDs.

  15. LANSCE personnel access control system

    SciTech Connect

    Sturrock, J.C.; Gallegos, F.R.; Hall, M.J.

    1997-01-01

    The Radiation Security System (RSS) at the Los Alamos Neutron Science Center (LANSCE) provides personnel protection from prompt radiation due to accelerated beam. The Personnel Access Control System (PACS) is a component of the RSS that is designed to prevent personnel access to areas where prompt radiation is a hazard. PACS was designed to replace several older personnel safety systems (PSS) with a single modem unified design. Lessons learned from the operation over the last 20 years were incorporated into a redundant sensor, single-point failure safe, fault tolerant, and tamper-resistant system that prevents access to the beam areas by controlling the access keys and beam stoppers. PACS uses a layered philosophy to the physical and electronic design. The most critical assemblies are battery backed up, relay logic circuits; less critical devices use Programmable Logic Controllers (PLCs) for timing functions and communications. Outside reviewers have reviewed the operational safety of the design. The design philosophy, lessons learned, hardware design, software design, operation, and limitations of the device are described.

  16. Keratoconus in USAF Flying Personnel

    DTIC Science & Technology

    Despite the rigid screening of all categories of rated personnel for the ability to meet stringent visual standards, cases of keratoconus continue to...entity. Aspects of incidence, early diagnosis, serial progression, and treatment are discussed. Two cases of keratoconus which developed after four years

  17. Rights & Responsibilities. Personnel Management Module.

    ERIC Educational Resources Information Center

    Barker, Gale; And Others

    This module on rights and responsibilities is intended to introduce the hospitality manager or supervisor to sound personnel management practices that comply with the law. The material is presented in a self-instructional format in seven sections. At the beginning of each section is a statement of the objectives that will be achieved as a result…

  18. Health Instruction Packages: Dental Personnel.

    ERIC Educational Resources Information Center

    Hayes, Gary E.; And Others

    Text, illustrations, and exercises are utilized in this set of four learning modules designed to instruct non-professional dental personnel in selected job-related skills. The first module, by Gary E. Hayes, describes how to locate the hinge axis point of the jaw, place and secure a bitefork, and perform a facebow transfer. The second module,…

  19. Occupational hazards to hospital personnel

    SciTech Connect

    Patterson, W.B.; Craven, D.E.; Schwartz, D.A.; Nardell, E.A.; Kasmer, J.; Noble, J.

    1985-05-01

    Hospital personnel are subject to various occupational hazards. Awareness of these risks, compliance with basic preventive measures, and adequate resources for interventions are essential components of an occupational health program. Physical, chemical, and radiation hazards; important infectious risks; and psychosocial problems prevalent in hospital workers are reviewed. A rational approach to managing and preventing these problems is offered. 370 references.

  20. Health Instruction Packages: Dental Personnel.

    ERIC Educational Resources Information Center

    Hayes, Gary E.; And Others

    Text, illustrations, and exercises are utilized in this set of four learning modules designed to instruct non-professional dental personnel in selected job-related skills. The first module, by Gary E. Hayes, describes how to locate the hinge axis point of the jaw, place and secure a bitefork, and perform a facebow transfer. The second module,…

  1. Source Book--Nursing Personnel.

    ERIC Educational Resources Information Center

    Spencer, William E.

    This book, organized in six chapters and a bibliography, presents historical and current statistics and references on the supply of nursing personnel within the United States. Chapter 1 includes a discussion of national estimates of the active nurse supply and the distribution of these nurses by field of practice and by academic preparation.…

  2. Source Book--Nursing Personnel.

    ERIC Educational Resources Information Center

    Spencer, William E.

    This book, organized in six chapters and a bibliography, presents historical and current statistics and references on the supply of nursing personnel within the United States. Chapter 1 includes a discussion of national estimates of the active nurse supply and the distribution of these nurses by field of practice and by academic preparation.…

  3. Simulation in Preparing School Personnel.

    ERIC Educational Resources Information Center

    Cruickshank, Donald R.; Broadbent, Frank W.

    The purpose of this state-of-the-art paper is to provide an overview of simulation ("a representation of several variables in the same arrangement as they occur in a particular natural or artificial system"), particularly as it relates to the professional preparation of school personnel. After distinguishing between "simulation" and "simulation…

  4. College Student Personnel Graduate Placement

    ERIC Educational Resources Information Center

    Greer, Richard M.; And Others

    1978-01-01

    This study reports results of ACPA Commission XII's survey of 101 college student personnel training institutions regarding their graduate placement. Graduates were identified according to degree, race, and sex. Percentages of graduates placed, specialty areas, types of institutions, areas of the country, and time and method of placement were…

  5. 40 CFR 792.29 - Personnel.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) GOOD LABORATORY PRACTICE STANDARDS Organization and Personnel § 792.29 Personnel. (a) Each individual.... (b) Each testing facility shall maintain a current summary of training and experience and...

  6. 40 CFR 792.29 - Personnel.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) GOOD LABORATORY PRACTICE STANDARDS Organization and Personnel § 792.29 Personnel. (a) Each individual.... (b) Each testing facility shall maintain a current summary of training and experience and...

  7. Personnel Management: A J/A Perspective

    ERIC Educational Resources Information Center

    Tasca, A. J.

    1974-01-01

    Recently, personnel executives and their staffs are being asked to help management solve an increasing number of human resource and business problems. Personnel management must undergo some changes if it is to achieve its full potential. (Author/AJ)

  8. The Control Process In Personnel Management

    ERIC Educational Resources Information Center

    Tracy, Lane

    1976-01-01

    The concept of human resource planning in personnel administration is gradually reintroducing the need for control over personnel functions as is usually demanded of other functions such as production and finance. (Author/TA)

  9. Personnel Management: A J/A Perspective

    ERIC Educational Resources Information Center

    Tasca, A. J.

    1974-01-01

    Recently, personnel executives and their staffs are being asked to help management solve an increasing number of human resource and business problems. Personnel management must undergo some changes if it is to achieve its full potential. (Author/AJ)

  10. 29 CFR 1926.1431 - Hoisting personnel.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... hard hats, employees must be protected by overhead protection on the personnel platform when employees... prohibited from traveling while personnel are hoisted. (l) (m) Pre-lift meeting. A pre-lift meeting must...

  11. 29 CFR 1926.1431 - Hoisting personnel.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... hard hats, employees must be protected by overhead protection on the personnel platform when employees... prohibited from traveling while personnel are hoisted. (l) (m) Pre-lift meeting. A pre-lift meeting must...

  12. Contact dermatitis in military personnel.

    PubMed

    Dever, Tara T; Walters, Michelle; Jacob, Sharon

    2011-01-01

    Military personnel encounter the same allergens and irritants as their civilian counterparts and are just as likely to develop contact dermatitis from common exposures encountered in everyday life. In addition, they face some unique exposures that can be difficult to avoid owing to their occupational duties. Contact dermatitis can be detrimental to a military member's career if he or she is unable to perform core duties or avoid the inciting substances. An uncontrolled contact dermatitis can result in the member's being placed on limited-duty (ie, nondeployable) status, needing a job or rate change, or separation from military service. We present some common causes of contact dermatitis in military personnel worldwide and some novel sources of contact dermatitis in this population that may not be intuitive.

  13. Personnel

    SciTech Connect

    2006-10-13

    Le président du conseil M.Doran explique la décision que le conseil du Cern vient de prendre sur la 4.étape du régime complémentaire des pensions. Le président du comité des finances le Dr.Andersen ainsi que le Prof.Connor(?) prennent aussi la parole

  14. Personnel

    ScienceCinema

    None

    2016-07-12

    Le président du conseil M.Doran explique la décision que le conseil du Cern vient de prendre sur la 4.étape du régime complémentaire des pensions. Le président du comité des finances le Dr.Andersen ainsi que le Prof.Connor(?) prennent aussi la parole

  15. 5 CFR 293.302 - Establishment of Official Personnel Folder.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 5 Administrative Personnel 1 2014-01-01 2014-01-01 false Establishment of Official Personnel Folder. 293.302 Section 293.302 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERSONNEL RECORDS Official Personnel Folder § 293.302 Establishment of Official Personnel Folder...

  16. 5 CFR 293.302 - Establishment of Official Personnel Folder.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 1 2011-01-01 2011-01-01 false Establishment of Official Personnel Folder. 293.302 Section 293.302 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERSONNEL RECORDS Official Personnel Folder § 293.302 Establishment of Official Personnel Folder...

  17. 5 CFR 293.302 - Establishment of Official Personnel Folder.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 5 Administrative Personnel 1 2013-01-01 2013-01-01 false Establishment of Official Personnel Folder. 293.302 Section 293.302 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERSONNEL RECORDS Official Personnel Folder § 293.302 Establishment of Official Personnel Folder...

  18. 5 CFR 293.302 - Establishment of Official Personnel Folder.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 5 Administrative Personnel 1 2012-01-01 2012-01-01 false Establishment of Official Personnel Folder. 293.302 Section 293.302 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERSONNEL RECORDS Official Personnel Folder § 293.302 Establishment of Official Personnel Folder...

  19. 5 CFR 293.302 - Establishment of Official Personnel Folder.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Establishment of Official Personnel Folder. 293.302 Section 293.302 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERSONNEL RECORDS Official Personnel Folder § 293.302 Establishment of Official Personnel...

  20. Comparative International Military Personnel Policies.

    DTIC Science & Technology

    1998-07-01

    Netherlands France Germany United Kingdom United Kingdom ( Chile ) The Netherlands Belgium The Netherlands Italy Denmark A workshop paper submitted by...115 Comparative International Military Personnel Policies 1. HISTORICAL ACCOUNT Chile had the first permanent army in America. It was founded...exemplified in the decisions taken by Ines de Suarez in the first years of the ’ Conquista ’, or afterwards by Sergeant ’Candelaria’ in the War of the Pacific

  1. Manpower planning for nurse personnel.

    PubMed Central

    Keaveny, T J; Hayden, R L

    1978-01-01

    A technique is described which can be applied to manpower planning for nurse personnel at a state or regional level. An iterative process explores the implications of alternative planning policy decision strategies intended to balance manpower supply and requirements. Impacts of the following policy alternatives are estimated: scale of operations of education institutions; interstate migration patterns; labor force participation rates; and job design of licensed practical nurse (LPN) and registered nurse (RN) positions. PMID:665883

  2. X-15 personnel July 1962

    NASA Image and Video Library

    1962-07-16

    X-15 personnel July 1962 Cockpit: Edward "Ed" Nice Ladder: Thomas "Tom" McAlister Back Row, left to right: William Clark, Edward "Ed" Sabo, Donald "Don" Hall, Billy Furr, Allen Dustin, Raymond "Ray" White, George E. Trott, Alfred "Al" Grieshaber, Merle Curtis, LeRoy "Lee" Adelsbach, Allen Lowe, Jay L. King, Lorenzo "Larry" Barnett. Kneeling, left to right: Byron Gibbs, Price "Bob" Workman, Ira Cupp, unidentified, John Gordon.

  3. Combat Attitudes of USAFE Personnel,

    DTIC Science & Technology

    1986-04-01

    characteristic that Air Force personnel stationed there must face a foreign environment. xil Chapter One INTRODUCTION Over the course of history , many military...calculated steps to ensure its soldiers are ready to fight. This could be more critical today than at any other time in history because of the...incredibly violent. The technology will be ultramodern; the psychological stresses on soldiers, as terrible and lonely as any in the history of warfare" (p

  4. Collaborative Operations for Personnel Recovery

    DTIC Science & Technology

    2008-02-01

    AFRL-RI-RS-TR-2008-26 Final Technical Report February 2008 COLLABORATIVE OPERATIONS FOR PERSONNEL RECOVERY University of...ADDRESS(ES) Artificial Intelligence Applications Institute The University of Edinburgh Appleton Tower, Crichton St. Edinburgh EH8 9LE, UK 8...under agreement number F30602-03-2-0014. The University of Edinburgh, the U.S. government and research sponsors are authorized to reproduce and

  5. Comparison of broad band time series recorded parallel by FGI type interferometric water level and Lippmann type pendulum tilt meters at Conrad observatory, Austria

    NASA Astrophysics Data System (ADS)

    Ruotsalainen, Hannu; Papp, Gabor; Leonhardt, Roman; Ban, Dora; Szücs, Eszter; Benedek, Judith

    2016-04-01

    The Finnish Geodetic Institute (FGI) the progenitor of Finnish Geospatial Research Institute of NLS designed and built a 5.5m long prototype of interferometric water level tiltmeter (iWT) in early 2014. Geodetic and Geophysical Institute (GGI), Sopron, Hungary bought the instrument and started tilt measurement in August 2014 at the Conrad observatory (COBS), Austria to monitor geodynamical phenomena like microseisms, free oscillations of the Earth, earth tides, mass loading effects and crustal deformations in cooperation with Austrian Central Institute for Meteorology and Geodynamics (ZAMG) and the FGI. On the July 16 2015 a Lippmann-type 2D tilt sensor (LTS) was also installed by GGI on the 6 m long pier where iWT was set up previously. This situation opens a possibility to do broad band (from secular to seismic variations up to 15 Hz) geophysical signal analysis comparing the responses of long (several meters) and short (a few decimeters) base instruments implementing different physical principles (relative height change of a level surface and inclination change of the plumb line). The characteristics of the sensors are studied by the evaluation of the spectra of recorded signals dominated by microseisms. The iWT has internal interferometric calibration and it can be compared to Lippmanns tilt meter one. Both instruments show good long term ( > 1 day) stability when earth tides and ocean and air mass loading tilts are modelled.

  6. 21 CFR 58.29 - Personnel.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 1 2011-04-01 2011-04-01 false Personnel. 58.29 Section 58.29 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL GOOD LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Organization and Personnel § 58.29 Personnel. (a) Each individual engaged...

  7. 21 CFR 58.29 - Personnel.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 1 2014-04-01 2014-04-01 false Personnel. 58.29 Section 58.29 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL GOOD LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Organization and Personnel § 58.29 Personnel. (a) Each individual engaged...

  8. 21 CFR 58.29 - Personnel.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Personnel. 58.29 Section 58.29 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL GOOD LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Organization and Personnel § 58.29 Personnel. (a) Each individual engaged...

  9. 21 CFR 58.29 - Personnel.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 1 2013-04-01 2013-04-01 false Personnel. 58.29 Section 58.29 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL GOOD LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Organization and Personnel § 58.29 Personnel. (a) Each individual engaged...

  10. 21 CFR 58.29 - Personnel.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 1 2012-04-01 2012-04-01 false Personnel. 58.29 Section 58.29 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL GOOD LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Organization and Personnel § 58.29 Personnel. (a) Each individual engaged...

  11. 14 CFR 145.151 - Personnel requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Personnel requirements. 145.151 Section 145.151 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Personnel § 145.151 Personnel requirements....

  12. 46 CFR 107.113 - Industrial personnel.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Industrial personnel. 107.113 Section 107.113 Shipping... CERTIFICATION General § 107.113 Industrial personnel. Industrial personnel are all persons, exclusive of the... unit for the sole purpose of carrying out the industrial business or functions of the unit. ...

  13. 21 CFR 211.28 - Personnel responsibilities.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... from contamination. (b) Personnel shall practice good sanitation and health habits. (c) Only personnel... Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS... instructed to report to supervisory personnel any health conditions that may have an adverse effect on...

  14. 76 FR 81359 - National Security Personnel System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-28

    ...;having general applicability and legal effect, most of which are keyed #0;to and codified in the Code of... MANAGEMENT 5 CFR Chapter XCIX RIN 3206-AM 53 National Security Personnel System AGENCY: Department of Defense... Defense and Office of Personnel Management regulations concerning the National Security Personnel System...

  15. The Changing World of Personnel Management.

    ERIC Educational Resources Information Center

    Anderson, Eileen R.

    Although personnel management in the public sector has become increasingly difficult because of recent social changes, more worker and middle management involvement in decision-making processes can improve all levels of personnel management. The social changes affecting personnel management have assumed three forms: (1) the entrance into the work…

  16. The Personnel Office and Computer Services: Tomorrow.

    ERIC Educational Resources Information Center

    Nicely, H. Phillip, Jr.

    1980-01-01

    It is suggested that the director of personnel should be making maximum use of available computer services. Four concerns of personnel directors are cited: number of government reports required, privacy and security, cost of space for personnel records and files, and the additional decision-making tools required for collective bargaining…

  17. Personnel Management for Effective Schools. Second Edition.

    ERIC Educational Resources Information Center

    Seyfarth, John T.

    Myriad issues face those who manage school personnel. Explicating the wide range of activities covered by the term "personnel management" is the object of this text. It is geared for prospective and current school administrators whose responsibilities include any aspect of personnel management. The text is organized around the premise that student…

  18. Personnel Development Practices in Turkish Education System

    ERIC Educational Resources Information Center

    Ozdemir, Tuncay Yavuz

    2016-01-01

    Nowadays everything develops and changes very quickly and sustainability of organizational goals will be possible only when personnel can keep up with these changes. From administrative aspect it is important to enhance personnel's potential and prompt them to achieve organizational goals. Personnel development is a process which influences and…

  19. The Changing World of Personnel Management.

    ERIC Educational Resources Information Center

    Anderson, Eileen R.

    Although personnel management in the public sector has become increasingly difficult because of recent social changes, more worker and middle management involvement in decision-making processes can improve all levels of personnel management. The social changes affecting personnel management have assumed three forms: (1) the entrance into the work…

  20. Personnel Launch System (PLS) study

    NASA Technical Reports Server (NTRS)

    Ehrlich, Carl F., Jr.

    1991-01-01

    NASA is currently studying a personnel launch system (PLS) approach to help satisfy the crew rotation requirements for the Space Station Freedom. Several concepts from low L/D capsules to lifting body vehicles are being examined in a series of studies as a potential augmentation to the Space Shuttle launch system. Rockwell International Corporation, under contract to NASA, analyzed a lifting body concept to determine whether the lifting body class of vehicles is appropriate for the PLS function. The results of the study are given.

  1. BETA-GAMMA PERSONNEL DOSIMETER

    DOEpatents

    Davis, D.M.; Gupton, E.D.; Hart, J.C.; Hull, A.P.

    1961-01-17

    A personnel dosimeter is offered which is sensitive to both gamma and soft beta radiations from all directions within a hemisphere. The device is in the shape of a small pill box which is worn on a worker-s wrist. The top and sides of the device are provided with 50 per cent void areas to give 50 per cent response to the beta rays and complete response to the gamma rays. The device is so constructed as to have a response which will approximate the dose received by the basal layer of the human epidermis.

  2. Personnel Security Program. Change 2

    DTIC Science & Technology

    1993-07-14

    administrative action in a personnel security determination. # First Amendment (Ch 2, 7/14/93) 1-3 Jan 87# DoD 5200.2-R 1-312 National Agency Check (NAC) A... First Amendment (Ch 2, 7/14/93) 1-4 Jan 87# DoD 5200.2-R (1) The nature and seriousness of the conduct: (2) The circumstances surrounding the conduct...Acce-ioii For NTiS r(PA&J LI D ’••.:t . ,. ~ F .r...... An. .... # First Amendment (Ch 2, 7/14/93) VI-3 Jan 87# DoD5200.2-R 0 CHAPTER VII ISSUING

  3. Personnel occupied woven envelope robot

    NASA Technical Reports Server (NTRS)

    Wessling, F. C.

    1986-01-01

    The use of nonmetallic or fabric structures for space application is considered. The following structures are suggested: (1) unpressurized space hangars; (2) extendable tunnels for soft docking; and (3) manned habitat for space stations, storage facilities, and work structures. The uses of the tunnel as a passageway: for personnel and equipment, eliminating extravehicular activity, for access to a control cabin on a space crane and between free flyers and the space station are outlined. The personnal occupied woven envelope robot (POWER) device is shown. The woven envelope (tunnel) acts as part of the boom of a crane. Potential applications of POWER are outlined. Several possible deflection mechanisms and design criteria are determined.

  4. Seventh Personnel Dosimetry Intercomparison Study

    SciTech Connect

    Swaja, R.E.; Sims, C.S.; Greene, R.T.

    1981-12-01

    The Seventh Personnel Dosimetry Intercomparison Study was conducted March 31-April 10, 1981, at the Oak Ridge National Laboratory. Dosimeters from 34 participating agencies were mounted on anthropomorphic phantoms and exposed to a range of low-level dose equivalents (1.5-15.0mSv neutron and 0.1-2.8 mSv gamma) which could be encountered during routine personnel monitoring in mixed radiation fields. The Health Physics Research Reactor, operating in the steady-state mode, served as the source of radiation for two equivalent sets of six separate exposures. Lucite and concrete shields along with the unshielded reactor provided three different neutron and gamma spectra for five of the exposures in each set. Results reported by the participating agencies showed that no single type of neutron dosimeter exhibited acceptable performance characteristics for all mixed-field environments encountered in this study. Film, TLD, and TLD-albed dosimeters were found to be inadequate for neutron dose equivalent measurements when large numbers of slow neutrons are present unless significant corrections are made to measured results. Track dosimeters indicated the least sensitivity to spectral characteristics, but did not always yield to the most accurate results. Gamma dose measurements showed that TLD-700 dosimeters produced significantly more accurate results than film dosimeters which tend to overestimate gamma doses in mixed radiation fields.

  5. [Preventive vaccinations for medical personnel].

    PubMed

    Kerwat, Klaus; Goedecke, Marcel; Wulf, Hinnerk

    2014-05-01

    Vaccinations are among the most efficient and important preventive medical procedures. Modern vaccines are well tolerated. In Germany there are no longer laws for mandatory vaccinations, either for the general public or for medical personnel. Vaccinations are now merely "officially recommended" by the top health authorities on the basis of recommendations from the Standing Committee on Vaccinations (STIKO) of the Robert Koch Institute (RKI) according to § 20 para 3 of the Protection against Infection law (IfSG). The management of vaccine damage due to officially recommended vaccinations is guaranteed by the Federal States. Whereas vaccinations in childhood are generally considered to be a matter of course, the willingness to accept them decreases markedly with increasing age. In the medical sector vaccinations against, for example, hepatitis B are well accepted while other vaccinations against, for example, whooping cough or influenza are not considered to be so important. The fact that vaccinations, besides offering protection for the medical personnel, may also serve to protect the patients entrusted to medical care from nosocomial infections is often ignored.

  6. 5 CFR 250.202 - Office of Personnel Management responsibilities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 5 Administrative Personnel 1 2012-01-01 2012-01-01 false Office of Personnel Management responsibilities. 250.202 Section 250.202 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERSONNEL MANAGEMENT IN AGENCIES Strategic Human Capital Management § 250.202 Office of Personnel...

  7. 5 CFR 250.202 - Office of Personnel Management responsibilities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 5 Administrative Personnel 1 2013-01-01 2013-01-01 false Office of Personnel Management responsibilities. 250.202 Section 250.202 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERSONNEL MANAGEMENT IN AGENCIES Strategic Human Capital Management § 250.202 Office of Personnel...

  8. 5 CFR 250.202 - Office of Personnel Management responsibilities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 5 Administrative Personnel 1 2014-01-01 2014-01-01 false Office of Personnel Management responsibilities. 250.202 Section 250.202 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERSONNEL MANAGEMENT IN AGENCIES Strategic Human Capital Management § 250.202 Office of Personnel...

  9. 5 CFR 250.202 - Office of Personnel Management responsibilities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 1 2011-01-01 2011-01-01 false Office of Personnel Management responsibilities. 250.202 Section 250.202 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERSONNEL MANAGEMENT IN AGENCIES Strategic Human Capital Management § 250.202 Office of Personnel...

  10. Characteristics of a 85Kr beta-particle source applied in Series 1 reference irradiations of DIS-1 direct ion storage dosemeters.

    PubMed

    Hakanen, A T; Sipilä, P M; Sahla, T T

    2007-01-01

    Characteristics necessary to specify an ISO 6980 Series 1 reference radiation field were determined for a commercially available 85Kr beta-particle source, using a BEAM EGS4 Monte Carlo code. The characteristics include residual maximum beta energy, E(res), and the uniformity of the dose rate over the calibration area. The E(res) and the uniformity were also determined experimentally, using an extrapolation ionization chamber (EC) and a 0.2 cm3 parallel plate ionization chamber, respectively. The depth-dose curve measured with the EC gave a value 0.62 MeV for the E(res). Series 2 90Sr + 90Y and Series 1(85) Kr beta-particle sources calibrated for H(p)(0.07) at the secondary standard dosimetry laboratory (SSDL) of STUK were used to determine the energy and angular responses of DIS-1 direct ion storage dosemeters. The averaged zero angle H(p)(0.07) responses to the 90Sr + 90Y and 85Kr reference radiations were 135 and 80%, respectively. The responses were normalized to 100%, H(p)(0.07) response to 137Cs photon radiation.

  11. Personnel administration can act on cost containment.

    PubMed

    Adams, J

    1980-01-01

    Hosiptal personnel administration programs have the potential to contain costs in a variety of areas, including human resources management, payroll costs, benefits costs, labor turnover, and recruitment costs. Recognizing this, the Maine Society for Hospital Personnel Administration presented a seminar and prepared a guide for trustees and administrators on the role that personnel administration can play in the Voluntary Effort to contain costs. The following article is an adaptation of the information included in the seminar and guide.

  12. Computer-assisted warehouse personnel scheduling

    NASA Astrophysics Data System (ADS)

    Parker, Sandra C.; Malstrom, Eric J.; Usmani, Tariq

    1992-02-01

    A decision support system is developed for personnel scheduling in a multiple warehouse environment. The system incorporates current manpower level, historical data of workers used, empirical load distributions, and performance standards to generate manpower requirements for a specified planning horizon. The software has been developed to be easily adaptable to varying situational details, therefore is widely applicable in different warehouse settings. The system offers personnel managers a valuable tool for evaluating alternative schedules and making intelligent decisions regarding personnel scheduling in warehouses.

  13. Reusable ultralight personnel carrier (RUPC)

    NASA Technical Reports Server (NTRS)

    Clark, B. C., III; Mccandless, B., II

    1992-01-01

    Attention is given to a personnel-carrying space vehicle concept developed to minimize the cost of access to LEO. The RUPC could provide alternate access to Space Station Freedom (SSF) for six passengers per flight. It can also bring and return small amounts of cargo, up to and including one SSF double rack. These capabilities are ideal for utilization flights during man-tended operations at SSF and for crew rotation during permanently manned periods. The RUPC is a reusable conical reentry vehicle and disposable adapter with propulsion and power subsystems. Avionics subsystem benefit from advanced low-power high-performance microelectronics developed for both the civilian and military space sectors. The RUPC core cabin concept has growth potential for other applications, including assured crew return, ground-launched crew rescue, delivery and retrieval of SSF cargo, and crew cabin for flights to the moon.

  14. [Hip replacement in military personnel].

    PubMed

    Maksimov, I B; Paniushin, K A; Brizhan', L K; Buriachenko, B P; Varfolomeev, D I; Mimanchev, O V

    2014-01-01

    Hip joint diseases and injuries are common for orthopedic pathology among military personnel. Hip replacement is one of the most frequent operations. Authors evaluated hip replacement in 136 servicemen treated at the center of traumatology and orthopedics of Burdenko General Military Clinical Hospital of the Ministry of Defense of Russia in 2010-2013. On the basis of the conducted analysis the main disease groups were revealed, peculiarities of pathology among this category of patients. Authors proposed surgical doctrine for the treatment of this contingent. Effective surgical treatment, in particular, hip replacement surgery, conducted with the use of the proposed principles, as a rule, fully functionally cured patients and contributes to return them in the system that contributes to the strengthening of defensibility of the country.

  15. Qualifications and certification of nondestructive testing personnel

    NASA Technical Reports Server (NTRS)

    Kirk, M. K.

    1971-01-01

    Personnel handbook states criteria for test methods including radiation, ultrasonics, eddy current, liquid penetrant, and magnetic particle. Subject categories are thoroughly defined and substructured.

  16. 34 CFR 303.169 - Personnel standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... REHABILITATIVE SERVICES, DEPARTMENT OF EDUCATION EARLY INTERVENTION PROGRAM FOR INFANTS AND TODDLERS WITH... Personnel standards. (a) Each application must include policies and procedures that are consistent with the...

  17. 33 CFR 127.707 - Security personnel.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) WATERFRONT FACILITIES WATERFRONT FACILITIES HANDLING LIQUEFIED NATURAL GAS AND LIQUEFIED HAZARDOUS GAS Waterfront Facilities Handling Liquefied Natural Gas Security § 127.707 Security personnel. The...

  18. Draft registration of health care personnel.

    PubMed

    Lott, C M

    1991-04-01

    A chronic shortage of health care personnel in the active and reserve forces continues to be of concern, particularly in planning for national emergencies or war. Congress has authorized the Selective Service System to establish a system to register and classify health care personnel rapidly in the event a national emergency requires implementation of a draft for the armed services. This paper describes the creation of the Health Care Personnel Delivery System. It provides a brief history of previous military drafts for health care personnel and describes the principal differences in the way a draft registration program may operate in the future.

  19. 10 CFR 39.65 - Personnel monitoring.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Personnel monitoring. 39.65 Section 39.65 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Radiation Safety Requirements § 39.65 Personnel monitoring. (a) The licensee may not permit an individual to act as a...

  20. 21 CFR 606.20 - Personnel.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Personnel. 606.20 Section 606.20 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS CURRENT GOOD MANUFACTURING PRACTICE FOR BLOOD AND BLOOD COMPONENTS Organization and Personnel §...

  1. 21 CFR 211.28 - Personnel responsibilities.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Personnel responsibilities. 211.28 Section 211.28 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Organization and Personnel §...

  2. 21 CFR 225.10 - Personnel.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 4 2012-04-01 2012-04-01 false Personnel. 225.10 Section 225.10 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR MEDICATED FEEDS General Provisions § 225.10 Personnel....

  3. 21 CFR 225.10 - Personnel.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 4 2013-04-01 2013-04-01 false Personnel. 225.10 Section 225.10 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR MEDICATED FEEDS General Provisions § 225.10 Personnel....

  4. 21 CFR 225.10 - Personnel.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 4 2011-04-01 2011-04-01 false Personnel. 225.10 Section 225.10 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR MEDICATED FEEDS General Provisions § 225.10 Personnel....

  5. 21 CFR 225.10 - Personnel.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Personnel. 225.10 Section 225.10 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR MEDICATED FEEDS General Provisions § 225.10 Personnel....

  6. 21 CFR 211.25 - Personnel qualifications.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Personnel qualifications. 211.25 Section 211.25 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Organization and Personnel §...

  7. 21 CFR 225.10 - Personnel.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 4 2014-04-01 2014-04-01 false Personnel. 225.10 Section 225.10 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR MEDICATED FEEDS General Provisions § 225.10 Personnel....

  8. Pupil Personnel Services: Statement of Functions.

    ERIC Educational Resources Information Center

    Cardinale, Anthony

    This statement of function for pupil personnel services (PPS) in the Department of Defense Dependents Schools (DDDS) focuses on the support role of pupil personnel workers. General, program, and specific functions of school counselors and psychologists, social workers, educational prescriptionists, school health nurses, and resident hall advisors…

  9. Pupil Personnel Services: Material Review List Recommendations.

    ERIC Educational Resources Information Center

    Cardinale, Anthony

    This list of materials provides recommendations to counselors and guidance personnel for the purchase of materials for pupil personnel services programs in the Department of Defense Dependents Schools (DDDS). The listing, based on staff reviews in each of the six DDDS regions, is divided into 10 content areas: (1) assessment and evaluation; (2)…

  10. The Implementation of the Program Personnel Support

    ERIC Educational Resources Information Center

    Veynbender, Tatyana; Vershinina, Svetlana

    2016-01-01

    The article contains analysis software products used in the preparation of professionals through which they can realize themselves in this industry. The aim of the study is the analysis of personnel petroleum education in specialized university. The result is a sociological study on the question of the need and importance of personnel support…

  11. 9 CFR 2.32 - Personnel qualifications.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false Personnel qualifications. 2.32 Section 2.32 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE ANIMAL WELFARE REGULATIONS Research Facilities § 2.32 Personnel qualifications. (a) It shall be...

  12. 9 CFR 2.32 - Personnel qualifications.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false Personnel qualifications. 2.32 Section 2.32 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE ANIMAL WELFARE REGULATIONS Research Facilities § 2.32 Personnel qualifications. (a) It shall be...

  13. 9 CFR 2.32 - Personnel qualifications.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false Personnel qualifications. 2.32 Section 2.32 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE ANIMAL WELFARE REGULATIONS Research Facilities § 2.32 Personnel qualifications. (a) It shall be...

  14. 9 CFR 2.32 - Personnel qualifications.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Personnel qualifications. 2.32 Section 2.32 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE ANIMAL WELFARE REGULATIONS Research Facilities § 2.32 Personnel qualifications. (a) It shall be...

  15. Modeling Personnel Turnover in the Parametric Organization

    NASA Technical Reports Server (NTRS)

    Dean, Edwin B.

    1991-01-01

    A primary issue in organizing a new parametric cost analysis function is to determine the skill mix and number of personnel required. The skill mix can be obtained by a functional decomposition of the tasks required within the organization and a matrixed correlation with educational or experience backgrounds. The number of personnel is a function of the skills required to cover all tasks, personnel skill background and cross training, the intensity of the workload for each task, migration through various tasks by personnel along a career path, personnel hiring limitations imposed by management and the applicant marketplace, personnel training limitations imposed by management and personnel capability, and the rate at which personnel leave the organization for whatever reason. Faced with the task of relating all of these organizational facets in order to grow a parametric cost analysis (PCA) organization from scratch, it was decided that a dynamic model was required in order to account for the obvious dynamics of the forming organization. The challenge was to create such a simple model which would be credible during all phases of organizational development. The model development process was broken down into the activities of determining the tasks required for PCA, determining the skills required for each PCA task, determining the skills available in the applicant marketplace, determining the structure of the dynamic model, implementing the dynamic model, and testing the dynamic model.

  16. 33 CFR 157.154 - Assistant personnel.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) POLLUTION RULES FOR THE PROTECTION OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Crude Oil Washing (COW) System on Tank Vessels Personnel § 157.154 Assistant personnel. The owner... the Crude Oil Washing Operations and Equipment Manual approved by the Coast Guard under § 157.112...

  17. 33 CFR 157.154 - Assistant personnel.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) POLLUTION RULES FOR THE PROTECTION OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Crude Oil Washing (COW) System on Tank Vessels Personnel § 157.154 Assistant personnel. The owner... the Crude Oil Washing Operations and Equipment Manual approved by the Coast Guard under § 157.112...

  18. 33 CFR 157.154 - Assistant personnel.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) POLLUTION RULES FOR THE PROTECTION OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Crude Oil Washing (COW) System on Tank Vessels Personnel § 157.154 Assistant personnel. The owner... the Crude Oil Washing Operations and Equipment Manual approved by the Coast Guard under § 157.112...

  19. 33 CFR 157.154 - Assistant personnel.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) POLLUTION RULES FOR THE PROTECTION OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Crude Oil Washing (COW) System on Tank Vessels Personnel § 157.154 Assistant personnel. The owner... the Crude Oil Washing Operations and Equipment Manual approved by the Coast Guard under § 157.112...

  20. 33 CFR 157.154 - Assistant personnel.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) POLLUTION RULES FOR THE PROTECTION OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Crude Oil Washing (COW) System on Tank Vessels Personnel § 157.154 Assistant personnel. The owner... the Crude Oil Washing Operations and Equipment Manual approved by the Coast Guard under § 157.112...

  1. Job Attitudes of Air National Guard Personnel.

    DTIC Science & Technology

    1986-04-01

    1 CHAPTER FOUR--RESULTS Examination 1-- Analysis of Demographic I nformation...personnel and how these attitudes compare with those of Air Force personnel, an analysis of the results of the Leadership and Management Development Center’s...discusses the LMDC/OAP survey instrument used, how the survey was administered, subjects surveyed and the data analysis procedures. Chapter Four presents

  2. 21 CFR 114.10 - Personnel.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Personnel. 114.10 Section 114.10 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION ACIDIFIED FOODS General Provisions § 114.10 Personnel. All operators of processing and...

  3. 10 CFR 39.65 - Personnel monitoring.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Personnel monitoring. 39.65 Section 39.65 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Radiation Safety Requirements § 39.65 Personnel monitoring. (a) The licensee may not permit an individual to act as a logging...

  4. United States Health Workforce Personnel Factbook.

    ERIC Educational Resources Information Center

    Health Resources and Services Administration (DHHS/PHS), Rockville, MD. Bureau of Health Professions.

    This factbook is a compilation of data from secondary sources such as the American Medical Association and the Federal Bureau of Labor Statistics. It includes information on the supply of health personnel in several disciplines, including physicians, physician assistants, podiatrists, dentists, nursing personnel, optometrists, pharmacists,…

  5. 33 CFR 143.105 - Personnel landings.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Personnel landings. 143.105 Section 143.105 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES DESIGN AND EQUIPMENT OCS Facilities § 143.105 Personnel landings....

  6. Managing the Reduction in Military Personnel

    DTIC Science & Technology

    1990-07-01

    second, and possibly third reenlistments; and selection of some personnel for early retirement . A Sustaining Level of Accessions. The long-term size...Air Force might be selected for involuntary early retirement in 1991. This number would represent about 5 percent of personnel eligible for retirement

  7. Management & Supervision Personnel Administration Training; General Reference.

    ERIC Educational Resources Information Center

    United States Government Printing Office, Washington, DC. Training and Career Development Div.

    This report lists 329 books in the library of the Training and Career Development Division of the Personnel Service. The books are listed under six categories. They are: personnel administration (46), management and supervision (60), general reference (57), training (20), American Management Association (AMA) publications (118), and United States…

  8. The Quiet Revolution in Public Personnel Laws

    ERIC Educational Resources Information Center

    Couturier, Jean J.

    1976-01-01

    Discusses Chicago's recent adoption of a new personnel system patterned closely after the Model Public Personnel Administration Law developed by the National Civil Service League (NCSL). Describes major provisions of NCSL's model law and relates the process used by NCSL to develop, evaluate, and encourage adoption of the model law. (JG)

  9. 14 CFR 13.21 - Military personnel.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Military personnel. 13.21 Section 13.21... INVESTIGATIVE AND ENFORCEMENT PROCEDURES Legal Enforcement Actions § 13.21 Military personnel. If a report made... civilian employee of the Department of Defense who is subject to the Uniform Code of Military Justice (10...

  10. 49 CFR 1503.407 - Military personnel.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 9 2014-10-01 2014-10-01 false Military personnel. 1503.407 Section 1503.407... Assessment of Civil Penalties by TSA § 1503.407 Military personnel. If a report made under this part... the Department of Defense who is subject to the Uniform Code of Military Justice (10 U.S.C. chapter...

  11. 7 CFR 1400.213 - Military personnel.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 10 2011-01-01 2011-01-01 false Military personnel. 1400.213 Section 1400.213... AND SUBSEQUENT CROP, PROGRAM, OR FISCAL YEARS Payment Eligibility § 1400.213 Military personnel. If a person is called to active duty in the military before a determination is made that the person...

  12. 7 CFR 1400.213 - Military personnel.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 10 2014-01-01 2014-01-01 false Military personnel. 1400.213 Section 1400.213... AND SUBSEQUENT CROP, PROGRAM, OR FISCAL YEARS Payment Eligibility § 1400.213 Military personnel. If a person is called to active duty in the military before a determination is made that the person...

  13. 49 CFR 1503.407 - Military personnel.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 9 2012-10-01 2012-10-01 false Military personnel. 1503.407 Section 1503.407... Assessment of Civil Penalties by TSA § 1503.407 Military personnel. If a report made under this part... the Department of Defense who is subject to the Uniform Code of Military Justice (10 U.S.C. chapter...

  14. 49 CFR 1503.407 - Military personnel.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 9 2013-10-01 2013-10-01 false Military personnel. 1503.407 Section 1503.407... Assessment of Civil Penalties by TSA § 1503.407 Military personnel. If a report made under this part... the Department of Defense who is subject to the Uniform Code of Military Justice (10 U.S.C. chapter...

  15. 14 CFR 13.21 - Military personnel.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Military personnel. 13.21 Section 13.21... INVESTIGATIVE AND ENFORCEMENT PROCEDURES Legal Enforcement Actions § 13.21 Military personnel. If a report made... civilian employee of the Department of Defense who is subject to the Uniform Code of Military Justice (10...

  16. 14 CFR 13.21 - Military personnel.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Military personnel. 13.21 Section 13.21... INVESTIGATIVE AND ENFORCEMENT PROCEDURES Legal Enforcement Actions § 13.21 Military personnel. If a report made... civilian employee of the Department of Defense who is subject to the Uniform Code of Military Justice (10...

  17. 7 CFR 1400.213 - Military personnel.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 10 2012-01-01 2012-01-01 false Military personnel. 1400.213 Section 1400.213... AND SUBSEQUENT CROP, PROGRAM, OR FISCAL YEARS Payment Eligibility § 1400.213 Military personnel. If a person is called to active duty in the military before a determination is made that the person...

  18. 7 CFR 1400.213 - Military personnel.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 10 2013-01-01 2013-01-01 false Military personnel. 1400.213 Section 1400.213... AND SUBSEQUENT CROP, PROGRAM, OR FISCAL YEARS Payment Eligibility § 1400.213 Military personnel. If a person is called to active duty in the military before a determination is made that the person...

  19. 33 CFR 154.840 - Personnel training.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Personnel training. 154.840... Personnel training. (a) A person in charge of a transfer operation utilizing a vapor control system must have completed a training program covering the particular system installed at the facility. Training...

  20. 33 CFR 154.840 - Personnel training.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Personnel training. 154.840... Personnel training. (a) A person in charge of a transfer operation utilizing a vapor control system must have completed a training program covering the particular system installed at the facility. Training...

  1. 33 CFR 154.840 - Personnel training.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Personnel training. 154.840... Personnel training. (a) A person in charge of a transfer operation utilizing a vapor control system must have completed a training program covering the particular system installed at the facility. Training...

  2. 21 CFR 211.25 - Personnel qualifications.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 4 2011-04-01 2011-04-01 false Personnel qualifications. 211.25 Section 211.25 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Organization and Personnel § 211...

  3. Personnel Utilization in Libraries, Selected Papers.

    ERIC Educational Resources Information Center

    Rockwood, Ruth H., Ed.

    An institute on the utilization of personnel in libraries was conducted by the Florida State University School of Library Science in October, 1969. Papers presented are grouped into the following three broad categories: (1) changing attitudes toward personnel administration, (2) procedures for selecting middle management and (3) ways and means of…

  4. 21 CFR 820.25 - Personnel.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Personnel. 820.25 Section 820.25 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES QUALITY SYSTEM REGULATION Quality System Requirements § 820.25 Personnel. (a) General. Each...

  5. A Systems Approach to Student Personnel Services.

    ERIC Educational Resources Information Center

    Norfleet, Morris

    Increased enrollment and student activism has created a situation within student personnel services that almost defies most management systems. A systems approach can enable student personnel services to evaluate what they are doing to determine if counselors are making a difference in the lives of students. The characteristics of this approach…

  6. 21 CFR 226.10 - Personnel.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Personnel. 226.10 Section 226.10 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR TYPE A MEDICATED ARTICLES General Provisions § 226.10 Personnel...

  7. 33 CFR 127.707 - Security personnel.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Security personnel. 127.707 Section 127.707 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Waterfront Facilities Handling Liquefied Natural Gas Security § 127.707 Security personnel. The...

  8. 33 CFR 127.707 - Security personnel.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Security personnel. 127.707 Section 127.707 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Waterfront Facilities Handling Liquefied Natural Gas Security § 127.707 Security personnel. The...

  9. 33 CFR 127.707 - Security personnel.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Security personnel. 127.707 Section 127.707 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Waterfront Facilities Handling Liquefied Natural Gas Security § 127.707 Security personnel. The...

  10. 33 CFR 127.707 - Security personnel.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Security personnel. 127.707 Section 127.707 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Waterfront Facilities Handling Liquefied Natural Gas Security § 127.707 Security personnel. The...

  11. 20 CFR 416.1021 - Personnel.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Personnel. 416.1021 Section 416.1021 Employees' Benefits SOCIAL SECURITY ADMINISTRATION SUPPLEMENTAL SECURITY INCOME FOR THE AGED, BLIND, AND DISABLED Determinations of Disability Administrative Responsibilities and Requirements § 416.1021 Personnel...

  12. 20 CFR 404.1621 - Personnel.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Personnel. 404.1621 Section 404.1621 Employees' Benefits SOCIAL SECURITY ADMINISTRATION FEDERAL OLD-AGE, SURVIVORS AND DISABILITY INSURANCE (1950- ) Determinations of Disability Administrative Responsibilities and Requirements § 404.1621 Personnel. (a) Equal...

  13. Public Schools: Support Personnel, 2003-04.

    ERIC Educational Resources Information Center

    Wenger, Cheryl L., Comp.

    2004-01-01

    This listing contains numerical/statistical data on support personnel in Pennsylvania for 2003-04 as reported by school districts, intermediate units, area vocational-technical schools, charter schools, and consortium-operated alternative high schools that employ staff (e.g., Washington County Alternative School). Support personnel are grouped…

  14. Roadmap for Navy Civilian Personnel Research

    DTIC Science & Technology

    1984-05-10

    establishment, recom- mended changes, and pointed out desirable avenues for further research. Beltramo 1974 discussed cost issues related to the...Strategies," Public Personnel Management Journal, 1980, 184-191. Beltramo , M.N. Considering the cost of DoD personnel: A look at some issues requiring

  15. 21 CFR 820.25 - Personnel.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... QUALITY SYSTEM REGULATION Quality System Requirements § 820.25 Personnel. (a) General. Each manufacturer... their specific jobs. (2) Personnel who perform verification and validation activities shall be made aware of defects and errors that may be encountered as part of their job functions....

  16. Support Personnel in Schools: Characteristics and Importance

    ERIC Educational Resources Information Center

    Conley, Sharon; Gould, Jewell; Levine, Harriet

    2010-01-01

    Purpose: Despite the critical role of support personnel in education, the literature about their supervision has been less than informative. In an effort to provide additional guidance to school leaders seeking to improve the supervision of such personnel, the purpose of this paper is to examine and compare three distinct groups of support…

  17. Michigan's Comprehensive Vocational Education Personnel Development Project.

    ERIC Educational Resources Information Center

    Ferns, George W.; Callahan, Gwen

    The report describes a project aimed at meeting inservice personnel development needs of secondary and postsecondary vocational educators in Michigan. Following an overview which details the development of the project, personnel categories, major events, and a seven-step process model, the report is arranged into 6 parts. The first component of…

  18. 21 CFR 114.10 - Personnel.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 2 2012-04-01 2012-04-01 false Personnel. 114.10 Section 114.10 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION ACIDIFIED FOODS General Provisions § 114.10 Personnel. All operators of processing and packaging...

  19. Misdirected Missionaries: Personnel Officers in Academe.

    ERIC Educational Resources Information Center

    Scott, Robert A.

    Personnel officers, like other middle-level collegiate administrators, have become so concerned with their status on campus that they have forgotten their role, which is to serve: to serve the goals of the institution, which are or should be educational goals established by the faculty and its leaders. Personnel is now a vulnerable area, but its…

  20. 21 CFR 21.32 - Personnel records.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Personnel Management, i.e., systems that: (i) The Office of Personnel Management maintains. (ii) Are maintained by the Division of Human Resources Management, Food and Drug Administration. (iii) Are maintained... accordance with 5 CFR 297.106, the Director, Division of Human Resources Management (HFA-400), Food and Drug...

  1. Student Personnel--All Hail and Farewell

    ERIC Educational Resources Information Center

    Crookston, Burns

    1976-01-01

    The alternating use and misuse of the terms student personnel work, student affairs and student development are discussed thoroughly. Here are recommendations: "student personnel work" should be put to rest; "student affairs" should be used in reference to actual services; and "student development" should apply to related philosophy and underlying…

  2. 34 CFR 300.207 - Personnel development.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 34 Education 2 2013-07-01 2013-07-01 false Personnel development. 300.207 Section 300.207 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF SPECIAL EDUCATION... CHILDREN WITH DISABILITIES Local Educational Agency Eligibility § 300.207 Personnel development. The LEA...

  3. 34 CFR 300.207 - Personnel development.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 34 Education 2 2010-07-01 2010-07-01 false Personnel development. 300.207 Section 300.207 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF SPECIAL EDUCATION... CHILDREN WITH DISABILITIES Local Educational Agency Eligibility § 300.207 Personnel development. The LEA...

  4. 34 CFR 300.207 - Personnel development.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 34 Education 2 2011-07-01 2010-07-01 true Personnel development. 300.207 Section 300.207 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF SPECIAL EDUCATION AND... DISABILITIES Local Educational Agency Eligibility § 300.207 Personnel development. The LEA must ensure that all...

  5. 34 CFR 300.207 - Personnel development.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 34 Education 2 2012-07-01 2012-07-01 false Personnel development. 300.207 Section 300.207 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF SPECIAL EDUCATION... CHILDREN WITH DISABILITIES Local Educational Agency Eligibility § 300.207 Personnel development. The LEA...

  6. 34 CFR 300.207 - Personnel development.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 34 Education 2 2014-07-01 2013-07-01 true Personnel development. 300.207 Section 300.207 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF SPECIAL EDUCATION AND... DISABILITIES Local Educational Agency Eligibility § 300.207 Personnel development. The LEA must ensure that all...

  7. 44 CFR 312.5 - Personnel.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SECURITY PREPAREDNESS USE OF CIVIL DEFENSE PERSONNEL, MATERIALS, AND FACILITIES FOR NATURAL DISASTER... contributions for training and education expenses. The following use of such personnel for natural disaster...-related disasters, States and their political subdivisions may include and provide for natural...

  8. 44 CFR 312.5 - Personnel.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... SECURITY PREPAREDNESS USE OF CIVIL DEFENSE PERSONNEL, MATERIALS, AND FACILITIES FOR NATURAL DISASTER... contributions for training and education expenses. The following use of such personnel for natural disaster...-related disasters, States and their political subdivisions may include and provide for natural...

  9. 44 CFR 312.5 - Personnel.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SECURITY PREPAREDNESS USE OF CIVIL DEFENSE PERSONNEL, MATERIALS, AND FACILITIES FOR NATURAL DISASTER... contributions for training and education expenses. The following use of such personnel for natural disaster...-related disasters, States and their political subdivisions may include and provide for natural...

  10. 44 CFR 312.5 - Personnel.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... PREPAREDNESS USE OF CIVIL DEFENSE PERSONNEL, MATERIALS, AND FACILITIES FOR NATURAL DISASTER PURPOSES § 312.5... training and education expenses. The following use of such personnel for natural disaster purposes is..., States and their political subdivisions may include and provide for natural disasters. (b)...

  11. 44 CFR 312.5 - Personnel.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... SECURITY PREPAREDNESS USE OF CIVIL DEFENSE PERSONNEL, MATERIALS, AND FACILITIES FOR NATURAL DISASTER... contributions for training and education expenses. The following use of such personnel for natural disaster...-related disasters, States and their political subdivisions may include and provide for natural...

  12. Personnel Management: Stewardship of Human Resources

    ERIC Educational Resources Information Center

    MacLean, Douglas G.

    1976-01-01

    The personnel function of top management is examined by first studying the environment in which top management functions. The basic skills required to perform the function are discussed. Against this background, six elements of personnel management in colleges and universities are considered: goals and objectives, organization for personnel…

  13. 14 CFR 13.21 - Military personnel.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Military personnel. 13.21 Section 13.21... INVESTIGATIVE AND ENFORCEMENT PROCEDURES Legal Enforcement Actions § 13.21 Military personnel. If a report made... civilian employee of the Department of Defense who is subject to the Uniform Code of Military Justice (10 U...

  14. 7 CFR 1400.213 - Military personnel.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Military personnel. 1400.213 Section 1400.213... AND SUBSEQUENT CROP, PROGRAM, OR FISCAL YEARS Payment Eligibility § 1400.213 Military personnel. If a person is called to active duty in the military before a determination is made that the person is...

  15. 49 CFR 1503.407 - Military personnel.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 9 2011-10-01 2011-10-01 false Military personnel. 1503.407 Section 1503.407... Assessment of Civil Penalties by TSA § 1503.407 Military personnel. If a report made under this part... the Department of Defense who is subject to the Uniform Code of Military Justice (10 U.S.C. chapter 47...

  16. 78 FR 43796 - Indebtedness of Military Personnel

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-22

    ... Department of the Army 32 CFR Part 513 Indebtedness of Military Personnel AGENCY: Department of the Army, DoD. ACTION: Final rule; removal. SUMMARY: This action removes regulations concerning indebtedness of military... CFR Part 112, ``Indebtedness of Military Personnel,'' and DoD Financial Management Review (FMR...

  17. 14 CFR 13.21 - Military personnel.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Military personnel. 13.21 Section 13.21... INVESTIGATIVE AND ENFORCEMENT PROCEDURES Legal Enforcement Actions § 13.21 Military personnel. If a report made... civilian employee of the Department of Defense who is subject to the Uniform Code of Military Justice (10 U...

  18. 33 CFR 154.840 - Personnel training.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Personnel training. 154.840... Personnel training. (a) A person in charge of a transfer operation utilizing a vapor control system must have completed a training program covering the particular system installed at the facility....

  19. 49 CFR 1503.407 - Military personnel.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Assessment of Civil Penalties by TSA § 1503.407 Military personnel. If a report made under this part... 49 Transportation 9 2010-10-01 2010-10-01 false Military personnel. 1503.407 Section 1503.407 Transportation Other Regulations Relating to Transportation (Continued) TRANSPORTATION SECURITY ADMINISTRATION...

  20. Recruitment and Retention of Assessment Personnel

    ERIC Educational Resources Information Center

    Simpson, Cynthia G.; Lynch, Sharon A.; Spencer, Vicky G.

    2007-01-01

    With a national shortage of special education personnel, including assessment personnel (Caranikas-Walker; Shapley, Cordeau, 2006; Karr, 2005), rural communities face serious challenges in retaining and recruiting highly qualified special education staff due to limited access to university training programs (Hausman & Hausman, 2003; Knapczyk,…

  1. NASP Issues Guidance on Personnel Evaluation

    ERIC Educational Resources Information Center

    Lazarus, Philip J.; Myers, Mary Alice; Skalski, Anastasia Kalamaros

    2012-01-01

    In November 2011, the National Association of School Psychologists (NASP) created the Personnel Assessment Task Force comprising national and state leaders with knowledge of effective personnel evaluation systems. Task force participants included school psychologist supervisors, university professors, NASP leadership, and staff. The primary…

  2. 10 CFR 39.65 - Personnel monitoring.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Personnel monitoring. 39.65 Section 39.65 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Radiation Safety Requirements § 39.65 Personnel monitoring. (a) The licensee may not permit an individual to act as a logging...

  3. 10 CFR 39.65 - Personnel monitoring.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Personnel monitoring. 39.65 Section 39.65 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Radiation Safety Requirements § 39.65 Personnel monitoring. (a) The licensee may not permit an individual to act as a logging...

  4. 10 CFR 39.65 - Personnel monitoring.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Personnel monitoring. 39.65 Section 39.65 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Radiation Safety Requirements § 39.65 Personnel monitoring. (a) The licensee may not permit an individual to act as a logging...

  5. Ambient gamma radiation levels (indoor and outdoor) in the villages around Jaduguda (India) using card-based CaSO₄: Dy TL dosemeters.

    PubMed

    Maharana, Mandakini; Swarnkar, M; Chougaonkar, M P; Mayya, Y S; Sengupta, D

    2011-01-01

    A systematic study of the gamma radiation levels (indoor and outdoor) in the villages surrounding the uranium-enriched regions around Jaduguda, India has been undertaken by monitoring selected dwellings in six villages. Each dwelling unit was monitored for a total duration of 1 y. The gamma radiation measurements were carried out using card-based CaSO(4): Dy thermoluminescent dosemeters. The estimated average annual gamma dose values for indoor and outdoor were 980 and 924 (µGy y(-1)), respectively, for the entire region studied. The maximum indoor and outdoor gamma doses experienced in North Dungridih and South Dungridih villages were 1305 and 1223 (µGy y(-1)), respectively. The minimum indoor and outdoor gamma dose values observed in Chatikocha village were 624 and 696 (µGy y(-1)), respectively. Seasonal variation of the indoor gamma values was not observed during the year; however, a small variation was seen with the type of building materials used for construction purposes. A statistical analysis was attempted to characterise the distribution of terrestrial gamma radiation obtained in the study area. The average quarterly indoor gamma values for spring, summer, monsoon and winter seasons as prevalent in the regions were 267±71, 262±54, 213±91, 238±66 (µGy 90 d(-1)), respectively. The annual effective doses to the local population residing in the selected dwelling units were estimated to be 0.6 and 0.1 (mSv y(-1)) for indoor and outdoor, respectively, using an occupancy factor of 0.8 and 0.2.

  6. Personnel occupied woven envelope robot

    NASA Technical Reports Server (NTRS)

    Wessling, Francis; Teoh, William; Ziemke, M. Carl

    1988-01-01

    The Personnel Occupied Woven Envelope Robot (POWER) provides an alternative to extravehicular activity (EVA) of space suited astronauts and/or use of long slender manipulator arms such as are used in the Shuttle Remote Manipulator System. POWER provides the capability for a shirt sleeved astronaut to perform such work by entering a control pod through air locks at both ends of an inflated flexible bellows (access tunnel). The exoskeleton of the tunnel is a series of six degrees of freedom (Six-DOF) articulated links compressible to 1/6 of their fully extended length. The operator can maneuver the control pod to almost any location within about 50 m of the base attachment to the space station. POWER can be envisioned as a series of hollow Six-DOF manipulator segments or arms wherein each arm grasps the shoulder of the next arm. Inside the hollow arms ia a bellow-type access tunnel. The control pod is the fist of the series of linked hollow arms. The fingers of the fist are conventional manipulator arms under direct visual control of the nearby operator in the pod. The applications and progress to date of the POWER system is given.

  7. Personnel occupied woven envelope robot

    NASA Technical Reports Server (NTRS)

    Wessling, Francis; Teoh, William; Ziemke, M. Carl

    1988-01-01

    The Personnel Occupied Woven Envelope Robot (POWER) provides an alternative to extravehicular activity (EVA) of space suited astronauts and/or use of long slender manipulator arms such as are used in the Shuttle Remote Manipulator System. POWER provides the capability for a shirt sleeved astronaut to perform such work by entering a control pod through air locks at both ends of an inflated flexible bellows (access tunnel). The exoskeleton of the tunnel is a series of six degrees of freedom (Six-DOF) articulated links compressible to 1/6 of their fully extended length. The operator can maneuver the control pod to almost any location within about 50 m of the base attachment to the space station. POWER can be envisioned as a series of hollow Six-DOF manipulator segments or arms wherein each arm grasps the shoulder of the next arm. Inside the hollow arms ia a bellow-type access tunnel. The control pod is the fist of the series of linked hollow arms. The fingers of the fist are conventional manipulator arms under direct visual control of the nearby operator in the pod. The applications and progress to date of the POWER system is given.

  8. 5 CFR 772.102 - Interim personnel actions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 2 2011-01-01 2011-01-01 false Interim personnel actions. 772.102 Section 772.102 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE REGULATIONS (CONTINUED) INTERIM RELIEF General § 772.102 Interim personnel actions. When an employee or...

  9. 5 CFR 300.706 - Office of Personnel Management adjudication.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 5 Administrative Personnel 1 2014-01-01 2014-01-01 false Office of Personnel Management adjudication. 300.706 Section 300.706 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE... Service Law § 300.706 Office of Personnel Management adjudication. (a) OPM will determine whether failure...

  10. 5 CFR 772.102 - Interim personnel actions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 5 Administrative Personnel 2 2013-01-01 2013-01-01 false Interim personnel actions. 772.102 Section 772.102 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE REGULATIONS (CONTINUED) INTERIM RELIEF General § 772.102 Interim personnel actions. When an employee or...

  11. 5 CFR 300.706 - Office of Personnel Management adjudication.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 5 Administrative Personnel 1 2012-01-01 2012-01-01 false Office of Personnel Management adjudication. 300.706 Section 300.706 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE... Service Law § 300.706 Office of Personnel Management adjudication. (a) OPM will determine whether failure...

  12. 5 CFR 772.102 - Interim personnel actions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 5 Administrative Personnel 2 2012-01-01 2012-01-01 false Interim personnel actions. 772.102 Section 772.102 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE REGULATIONS (CONTINUED) INTERIM RELIEF General § 772.102 Interim personnel actions. When an employee or...

  13. 5 CFR 300.706 - Office of Personnel Management adjudication.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 1 2011-01-01 2011-01-01 false Office of Personnel Management adjudication. 300.706 Section 300.706 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE... Service Law § 300.706 Office of Personnel Management adjudication. (a) OPM will determine whether failure...

  14. 5 CFR 300.706 - Office of Personnel Management adjudication.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 5 Administrative Personnel 1 2013-01-01 2013-01-01 false Office of Personnel Management adjudication. 300.706 Section 300.706 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE... Service Law § 300.706 Office of Personnel Management adjudication. (a) OPM will determine whether failure...

  15. 5 CFR 300.706 - Office of Personnel Management adjudication.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Office of Personnel Management adjudication. 300.706 Section 300.706 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE... Service Law § 300.706 Office of Personnel Management adjudication. (a) OPM will determine whether...

  16. 5 CFR 772.102 - Interim personnel actions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 2 2010-01-01 2010-01-01 false Interim personnel actions. 772.102 Section 772.102 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE REGULATIONS (CONTINUED) INTERIM RELIEF General § 772.102 Interim personnel actions. When an employee...

  17. Smokeless tobacco use in military personnel.

    PubMed

    Peterson, Alan L; Severson, Herb H; Andrews, Judy A; Gott, Sherrie P; Cigrang, Jeffrey A; Gordon, Judith S; Hunter, Christine M; Martin, Gary C

    2007-12-01

    Military personnel are more than twice as likely as civilians to use smokeless tobacco (ST), and recent studies indicate that military prevalence rates are rising. However, few studies have examined factors related to ST use in the military. The present study evaluated the characteristics of ST use in 785 active duty military personnel. The results indicated that the average age of initiation was 17.7 years, participants had used ST for 12.3 years, and they used approximately four tins or pouches of tobacco per week. Army personnel were more likely than Air Force personnel to be older, to have used ST longer, and to be heavier users. Officers had used ST longer than enlisted personnel and were more likely to have had a recent quit attempt. Enlisted personnel were more than three times as likely to report concurrent cigarette smoking. These results indicate that there are significant differences in ST use patterns in military personnel, and cessation programs should be tailored to meet these differences.

  18. KENNEDY SPACE CENTER, FLA. - Center Director Jim Kennedy (right) presents a plaque to Conrad Nagel who organized the Spaceport Super Safety and Health Day at KSC, an annual event dedicated to reinforcing safe and healthful behaviors in the workforce. Nagel is chief of the Shuttle Project Office, Shuttle Processing.

    NASA Image and Video Library

    2003-10-15

    KENNEDY SPACE CENTER, FLA. - Center Director Jim Kennedy (right) presents a plaque to Conrad Nagel who organized the Spaceport Super Safety and Health Day at KSC, an annual event dedicated to reinforcing safe and healthful behaviors in the workforce. Nagel is chief of the Shuttle Project Office, Shuttle Processing.

  19. Two-Term Survival of Female Personnel.

    DTIC Science & Technology

    1982-02-01

    rI ,AD-AIlS ൱ CENTER FOR NAVAL ANALYSES ALEXANDRIA VA NAVAL STUIE-ETC F/9 5/9 TWO-TERM SURVIVAL OF FEMALE PERSONNEL. (U) FED 82 P N LUPRIE NOOOI-7S...C-OOO1 U N C L ASIFFEE DCRC-460 ’o o ..r... CRC 460 / February 1962 TWO-TERM SURVIVAL OF FEMALE PERSONNEL Philip M. Lure CENTER FOR NAVAL ANALYSES 82...MUNGER CRC 460 -AM j// %___4__ 4. TITLE ts"ubifo) a. TYPE OF REOR A PERIOD COVERED Two-Term Survival of Female Personnel______________ apgnvomuuoo 0

  20. Energy response of different types of RADOS personal dosemeters with MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P) TL detectors.

    PubMed

    Obryk, B; Hranitzky, C; Stadtmann, H; Budzanowski, M; Olko, P

    2011-03-01

    The photon energy response of different RADOS (Mirion Technologies) personal dosemeters with MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P) thermoluminescence (TL) detectors was investigated. Three types of badges were applied. The irradiation with reference photon radiation qualities N (the narrow spectrum series), and S-Cs and S-Co nuclide radiation qualities, specified in ISO 4037 [International Organization for Standardization (ISO). X and gamma reference radiations for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy. ISO 4037. Part 1-4 (1999)], in the energy range of 16-1250 keV, were performed at the Dosimetry Laboratory Seibersdorf. The results demonstrated that a readout of a single MTS-N or MCP-N detector under the Al filter can be used to determine Hp(10) according to requirements of IEC 61066 [International Electrotechnical Commission (IEC). Thermoluminescence dosimetry systems for personal and environmental monitoring. International Standard IEC 61066 (2006)] for TL systems for personal dosimetry. The new RADOS badge with the experimental type of a holder (i.e. Cu/Al filters) is a very good tool for identifying the radiation quality (photon energy).

  1. Continuing Education for Your Bookstore Personnel.

    ERIC Educational Resources Information Center

    Weigand, Frances

    1978-01-01

    The Huntley Bookstore, which serves the five Claremont Colleges, encourages its personnel to participate in continuing education programs including management seminars, financial seminars, booksellers school, and conventions. Additional resources, such as college classes and professional organizations, are also considered. (JMD)

  2. 42 CFR 485.705 - Personnel qualifications.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., educational or vocational guidance, psychology, social work, special education or personnel administration... the requirements in part 484 of this chapter. (6) A social worker must meet the requirements in...

  3. On The Evolution of Student Personnel Workers

    ERIC Educational Resources Information Center

    Reisser, Linda

    1973-01-01

    This discussion of the evolution of student personnel workers and their plight as budgets have been tightened gives suggestions of ways this group could use their human relations expertise to recover from their current condition of institutional impotence. (JC)

  4. 21 CFR 1271.170 - Personnel.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... UNDER CERTAIN OTHER ACTS ADMINISTERED BY THE FOOD AND DRUG ADMINISTRATION HUMAN CELLS, TISSUES, AND CELLULAR AND TISSUE-BASED PRODUCTS Current Good Tissue Practice § 1271.170 Personnel. (a) General. You...

  5. 14 CFR 145.151 - Personnel requirements.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...) Provide qualified personnel to plan, supervise, perform, and approve for return to service the maintenance, preventive maintenance, or alterations performed under the repair station certificate and operations... in the performance of maintenance, preventive maintenance, or alterations authorized by the...

  6. 14 CFR 145.151 - Personnel requirements.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...) Provide qualified personnel to plan, supervise, perform, and approve for return to service the maintenance, preventive maintenance, or alterations performed under the repair station certificate and operations... in the performance of maintenance, preventive maintenance, or alterations authorized by the...

  7. 14 CFR 145.151 - Personnel requirements.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) Provide qualified personnel to plan, supervise, perform, and approve for return to service the maintenance, preventive maintenance, or alterations performed under the repair station certificate and operations... in the performance of maintenance, preventive maintenance, or alterations authorized by the...

  8. 14 CFR 145.151 - Personnel requirements.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...) Provide qualified personnel to plan, supervise, perform, and approve for return to service the maintenance, preventive maintenance, or alterations performed under the repair station certificate and operations... in the performance of maintenance, preventive maintenance, or alterations authorized by the...

  9. Outplacement--The New Personnel Practice.

    ERIC Educational Resources Information Center

    Driessnack, Carl H.

    1980-01-01

    Outlines the advantages of outplacement of redundant personnel both for the company and for the person terminated. Argues that companies should use outside consultants to run their outplacement programs. (IRT)

  10. 10 CFR 34.47 - Personnel monitoring.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... in place of ion-chamber pocket dosimeters. (2) Each personnel dosimeter must be assigned to and worn... associated with licensed material use until a determination of the individual's radiation exposure has...

  11. 10 CFR 34.47 - Personnel monitoring.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... in place of ion-chamber pocket dosimeters. (2) Each personnel dosimeter must be assigned to and worn... associated with licensed material use until a determination of the individual's radiation exposure has...

  12. 10 CFR 34.47 - Personnel monitoring.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... in place of ion-chamber pocket dosimeters. (2) Each personnel dosimeter must be assigned to and worn... associated with licensed material use until a determination of the individual's radiation exposure has...

  13. 10 CFR 34.47 - Personnel monitoring.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... in place of ion-chamber pocket dosimeters. (2) Each personnel dosimeter must be assigned to and worn... associated with licensed material use until a determination of the individual's radiation exposure has...

  14. Student Personnel Services for International Students

    ERIC Educational Resources Information Center

    Domingues, Patricia M.

    1970-01-01

    Examines literature to determine impact of foreign students on American campuses, reviews essentials necessary for providing effective services for them, speculates on future of advising them within realm of student personnel work. (Author)

  15. On The Evolution of Student Personnel Workers

    ERIC Educational Resources Information Center

    Reisser, Linda

    1973-01-01

    This discussion of the evolution of student personnel workers and their plight as budgets have been tightened gives suggestions of ways this group could use their human relations expertise to recover from their current condition of institutional impotence. (JC)

  16. 21 CFR 226.10 - Personnel.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... CURRENT GOOD MANUFACTURING PRACTICE FOR TYPE A MEDICATED ARTICLES General Provisions § 226.10 Personnel... and the safety, identity, strength, quality, and purity that it purports to possess. ...

  17. Space Shuttle Era: Astronaut Support Personnel

    NASA Image and Video Library

    Astronauts rely on other astronauts on launch day to help them get rady for liftoff and the misison ahead. The helpful cadre are known formally as Astronaut Support Personnel but are called ASPs or...

  18. Student Personnel Administration at the Small College.

    ERIC Educational Resources Information Center

    Palm, Richard L.

    1984-01-01

    Compares and contrasts the roles of student personnel administrators at small and large colleges. Defines and explores the background of small colleges and emphasizes the need for administrators to be current with trends in higher education. (JAC)

  19. Personnel occupied woven envelope robot power

    NASA Technical Reports Server (NTRS)

    Wessling, F. C.

    1988-01-01

    The Personnel Occupied Woven Envelope Robot (POWER) concept has evolved over the course of the study. The goal of the project was the development of methods and algorithms for solid modeling for the flexible robot arm.

  20. Guidelines for the calibration of personnel dosimeters

    SciTech Connect

    Roberson, P.L.; Holbrook, K.L.

    1984-01-01

    This guide describes minimum acceptable performance levels for personnel dosimetry systems used at Department of Energy (DOE) facilities. The goal is to improve both the quality of radiological calibrations and the methods of comparing reported occupational doses between DOE facilities. Reference calibration techniques are defined. A standard for evaluation of personnel dosimetry systems and recommended design parameters for personnel dosimeters are also included. Approximate intervals for the radiation energies for which these guidelines are appropriate are 15 keV to 2 MeV for photons; above 0.3 MeV for beta particles; and 1 keV to 2 MeV for neutrons. An analysis of ANSI N13.11 was completed using performance evaluations of selected personnel dosimetry systems in use at DOE facilities. The results of this analysis are incorporated in the guidelines.

  1. Student Personnel Administration at the Small College.

    ERIC Educational Resources Information Center

    Palm, Richard L.

    1984-01-01

    Compares and contrasts the roles of student personnel administrators at small and large colleges. Defines and explores the background of small colleges and emphasizes the need for administrators to be current with trends in higher education. (JAC)

  2. Reassessing training levels for prehospital EMS personnel.

    PubMed

    Briese, G L

    1983-01-01

    One of the major questions confronting prehospital care services today concerns determining the appropriate level of training for EMS personnel that will provide the most cost effective systems. Unfortunately there are no studies which assess this problem. Various communities have modified or expanded the roles of prehospital personnel beyond the traditional training of EMTs and paramedics. Continuing education and skills maintenance are ongoing problems faced by all EMS systems, which have been addressed in various ways by individual locales.

  3. The NASA personnel security processing expert system

    SciTech Connect

    Silberberg, D.; Thomas, R.

    1996-12-31

    The NASA Personnel Security Processing Expert System is a tool that automatically determines the appropriate personnel background investigation required for a civil servant or contractor occupying a position of national security or public trust. It also instructs the personnel security processing staff to perform special checks based on a specific position. The system is implemented using a rule-based expert system and a World Wide Web interface. The system design separates the user interface, knowledge base and control structure to simplify system evolution. When one subsystem is modified, the others are impacted minimally. This system provides many benefits to the NASA Personnel Security Program. First, it frees the agency personnel security specialist from trouble-shooting and correcting all investigative problems. It also provides a learning tool for security processing staff at each installation. The system ensures that each installation security office is in compliance with all applicable laws, regulations and policies. Finally, eliminating overlapping, inappropriate and duplicative efforts to process employees saves many resources. The system was deployed less than a year ago. To date, it saved $1.2 million of the $1.5 million agency-wide personnel security budget.

  4. Personnel Dose Assessment during Active Interrogation

    SciTech Connect

    Miller, Thomas Martin; Akkurt, Hatice; Patton, Bruce W

    2010-01-01

    A leading candidate in the detection of special nuclear material (SNM) is active interrogation (AI). Unlike passive interrogation, AI uses a source to enhance or create a detectable signal from SNM (usually fission), particularly in shielded scenarios or scenarios where the SNM has a low activity. The use of AI thus makes the detection of SNM easier or, in some scenarios, even enables previously impossible detection. During the development of AI sources, significant effort is put into determining the source strength required to detect SNM in specific scenarios. Usually during this process, but not always, an evaluation of personnel dose is also completed. In this instance personnel dose could involve any of the following: (1) personnel performing the AI; (2) unknown stowaways who are inside the object being interrogated; or (3) in clandestine interrogations, personnel who are known to be inside the object being interrogated but are unaware of the interrogation. In most instances, dose to anyone found smuggling SNM will be a secondary issue. However, for the organizations performing the AI, legal if not moral considerations should make dose to the personnel performing the AI, unknown stowaways, or innocent bystanders in clandestine interrogations a serious concern.

  5. Aggressive situational cues among Israeli security personnel.

    PubMed

    Bensimon, Moshe

    2015-05-01

    The present study enriches our knowledge on the relationship between security personnel and situational cues that may provoke aggression, such as arms and uniforms. The study examined 259 security personnel who completed an aggression questionnaire (AGQ). The study aimed (a) to compare the tendency toward aggression of security personnel who carry or do not carry arms and/or wear a uniform and (b) to compare the tendency toward aggression of men and women security personnel who carry or do not carry arms and/or wear a uniform. The findings indicated no main effect for aggression cueing classification. However, uniformed men had higher scores of physical aggression than women, and women scored significantly higher on anger than men when not carrying any aggressive cues. The findings also revealed that in general, men security personnel reported much higher physical aggression than women, while women showed slightly higher means of verbal aggression than men. The findings are discussed in light of the gender theory and research. © The Author(s) 2014.

  6. 34 CFR 303.360 - Comprehensive system of personnel development.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...; (3) Training personnel to work in rural and inner-city areas; and (4) Training personnel to... Intervention Services Personnel Training and Standards § 303.360 Comprehensive system of personnel development... inservice training to be conducted on an interdisciplinary basis, to the extent appropriate; (3) Provide for...

  7. 34 CFR 361.18 - Comprehensive system of personnel development.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... this paragraph must be described in a written plan that includes— (A) Specific strategies for retraining, recruiting, and hiring personnel; (B) The specific time period by which all State unit personnel... the State unit's progress in hiring or retraining personnel to meet applicable personnel standards...

  8. Personnel Administration in Higher Education. Handbook of Faculty and Staff Personnel Practices.

    ERIC Educational Resources Information Center

    Fortunato, Ray T.; Waddell, D. Geneva

    Ways to develop and implement personnel policies and procedures are described that should prevent problems from becoming crises in higher education institutions. Based on the authors' more than 40 years of combined experience in higher education personnel administration, this handbook offers a detailed guide to the intricacies of faculty and staff…

  9. Administration of Pupil Personnel Services. Pupil Personnel Services Recommended Practices and Procedures Manual.

    ERIC Educational Resources Information Center

    Irvin, Mari; Whiteside, David

    This volume, part of the Illinois State Board of Education's "Pupil Personnel Services Recommended Practices and Procedures Manual," deals with the administration of pupil personnel services (PPS). After a brief introduction, the following topics are covered: (1) major PPS concepts (including coordination of services, needs assessment,…

  10. A Management Study of Personnel Policies and the Department of Personnel Services.

    ERIC Educational Resources Information Center

    Cresap, McCormick, and Paget, Inc., Chicago, IL.

    The report presents the findings of a management study conducted to review personnel policies and practices in the Montgomery County (Maryland) Public School system. The study, part of a multiyear evaluation of the entire school system's management operation, examines personnel policies, procedures, and operations in the areas of recruitment,…

  11. Suicide rate among former Swedish peacekeeping personnel.

    PubMed

    Michel, Per-Olof; Lundin, Tom; Larsson, Gerry

    2007-03-01

    Increased suicide rates for military personnel suffering from post-traumatic stress disorders have been reported in various countries. Although it is known that some peacekeepers are exposed to potentially traumatic events and are thus at risk of suffering from post-traumatic stress reactions, only a few studies have examined suicide rates in this group. Therefore, the aim of this study was to investigate the suicide rate among former Swedish peacekeeping personnel. We compared 39,768 former Swedish peacekeepers to the general population in the National General Population Registry and the Cause-of-Death Registry. A lower number of suicides was found among former Swedish peacekeepers than in the general population. In conclusion, Swedish personnel serving in international peace-keeping operations do not show a higher suicide rate than the general population. Unique problems associated with this research area are discussed.

  12. Tetanus antitoxin titres in military personnel.

    PubMed

    Faithfull-Davies, D N; Parry, E S; Sheffield, F; Fieldhouse, P M; Boxall, M A

    1989-10-01

    A study was made of the titres of tetanus antitoxin in the sera of 186 recruits and 886 serving personnel. All were found to have titres of more than 0.01 IU per ml, the titre regarded as sufficient to provide protection from tetanus. The percentage of recruits with tetanus antitoxin titres less than 0.1 IU per ml was significantly greater than the percentage of serving personnel with antitoxin titres less than 0.1 IU per ml and the overall geometric mean titre of the antitoxin in the sera of the recruits was significantly lower than that in the sera of the serving personnel. In the light of the finding that all of the recruits had protective levels of tetanus antitoxin and in view of the imminent withdrawal of TABT Vaccine, alternative strategies for immunisation against tetanus are presented.

  13. DOD Personnel Clearances. DOD Faces Multiple Challenges in Its Efforts to Improve Clearance Processes for Industry Personnel

    DTIC Science & Technology

    2008-02-13

    Services, House of Representatives DOD PERSONNEL CLEARANCES DOD Faces Multiple Challenges in Its Efforts to Improve Clearance Processes for Industry...Personnel Clearances . DOD Faces Multiple Challenges in Its Efforts to Improve Clearance Processes for Industry Personnel 5a. CONTRACT NUMBER 5b...Accountability Office Why GAO Did This Study Highlights Accountability Integrity Reliability February 13, 2008 DOD PERSONNEL CLEARANCES DOD Faces Multiple

  14. Sleep Disorders in US Military Personnel

    PubMed Central

    Gill, Jessica; Lee, Hyunhwa; Baxter, Tristin; Pierce, Roslyn; Barr, Taura L.; Krakow, Barry; Roth, Bernard J.

    2013-01-01

    Background: Sleep disturbances are among the most common symptoms of military personnel who return from deployment. The objective of our study was to determine the presence of sleep disorders in US military personnel referred for evaluation of sleep disturbances after deployment and examine associations between sleep disorders and service-related diagnoses of depression, mild traumatic brain injury, pain, and posttraumatic stress disorder (PTSD). Methods: This was a cross-sectional study of military personnel with sleep disturbances who returned from combat within 18 months of deployment. Sleep disorders were assessed by clinical evaluation and polysomnogram with validated instruments to diagnose service-related illnesses. Results: Of 110 military personnel included in our analysis, 97.3% were men (mean age, 33.6 ± 8.0 years; mean BMI, 30.0 ± 4.3 kg/m2), and 70.9% returned from combat within 12 months. Nearly one-half (47.3%) met diagnostic criteria for two or more service-related diagnoses. Sleep disorders were diagnosed in 88.2% of subjects; 11.8% had a normal sleep evaluation and served as control subjects. Overall, 62.7% met diagnostic criteria for obstructive sleep apnea (OSA) and 63.6% for insomnia. The exclusive diagnoses of insomnia and OSA were present in 25.5% and 24.5% of subjects, respectively; 38.2% had comorbid insomnia and OSA. Military personnel with comorbid insomnia and OSA were significantly more likely to meet criteria for depression (P < .01) and PTSD (P < .01) compared with control subjects and those with OSA only. Conclusions: Comorbid insomnia and OSA is a frequent diagnosis in military personnel referred for evaluation of sleep disturbances after deployment. This diagnosis, which is difficult to treat, may explain the refractory nature of many service-related diagnoses. PMID:23681455

  15. PAMTRAK: A personnel and material tracking system

    SciTech Connect

    Anspach, D.A.; Anspach, J.P.; Walters, B.G.; Crain, B. Jr.

    1996-06-01

    There is a need for an automated system for protecting and monitoring sensitive or classified parts and material. Sandia has developed a real-time personnel and material tracking system (PAMTRAK) that has been installed at selected DOE facilities. It safeguards sensitive parts and material by tracking tags worn by personnel and by monitoring sensors attached to the parts or material. It includes remote control and alarm display capabilities and a complementary program in Keyhole to display measured material attributes remotely. This paper describes the design goals, the system components, current installations, and the benefits a site can expect when using PAMTRAK.

  16. The Full Cost of Military Personnel

    DTIC Science & Technology

    2016-03-01

    Direct costs are clearly linked to the compensation of individuals  Indirect costs cover overhead expenses not tracked to individuals  Current vs...service  In the Defense Department budget vs. in the budget of other government departments 1 Current Direct Costs of Military Personnel Basic...I N S T I T U T E F O R D E F E N S E A N A L Y S E S The Full Cost of Military Personnel Stanley A. Horowitz INSTITUTE FOR DEFENSE ANALYSES

  17. Allied dental personnel: will there be enough?

    PubMed

    Waldman, H Barry; Perlman, Steven P

    2008-11-01

    The escalating number and size of dental practices mean greater dependency on a ready supply of allied dental personnel. However, despite the increasing number of entry places in allied dental training programs, many places remain unfilled and large numbers of individuals do not complete the course of studies. A review of the changes in dental practice sizes and dental assistant, dental hygienist and dental laboratory technician programs raises concerns as to whether there will be enough allied dental personnel to meet the future needs of the profession. The need for increasing attention to this potential eventuality is stressed.

  18. Optimal Compensating Wages for Military Personnel

    ERIC Educational Resources Information Center

    Carrell, Scott E.; West, James E.

    2005-01-01

    The current U.S. military pay structure offers inequitable and inefficient wages across locations. Military personnel are paid less competitive wages in high-cost and/or low-amenity locations compared to low-cost and/or high-amenity locations. This pay system results in unequal reenlistment rates across locations, which leads to production…

  19. Computer Organizational Techniques Used by Office Personnel.

    ERIC Educational Resources Information Center

    Alexander, Melody

    1995-01-01

    According to survey responses from 404 of 532 office personnel, 81.7% enjoy working with computers; the majority save files on their hard drives, use disk labels and storage files, do not use subdirectories or compress data, and do not make backups of floppy disks. Those with higher degrees, more computer experience, and more daily computer use…

  20. 40 CFR 160.29 - Personnel.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 25 2012-07-01 2012-07-01 false Personnel. 160.29 Section 160.29 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS GOOD LABORATORY... facility shall maintain a current summary of training and experience and job description for...

  1. 40 CFR 160.29 - Personnel.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 24 2011-07-01 2011-07-01 false Personnel. 160.29 Section 160.29 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS GOOD LABORATORY... facility shall maintain a current summary of training and experience and job description for...

  2. 40 CFR 160.29 - Personnel.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Personnel. 160.29 Section 160.29 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS GOOD LABORATORY... facility shall maintain a current summary of training and experience and job description for...

  3. 40 CFR 160.29 - Personnel.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 24 2014-07-01 2014-07-01 false Personnel. 160.29 Section 160.29 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS GOOD LABORATORY... facility shall maintain a current summary of training and experience and job description for...

  4. 40 CFR 160.29 - Personnel.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 25 2013-07-01 2013-07-01 false Personnel. 160.29 Section 160.29 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS GOOD LABORATORY... facility shall maintain a current summary of training and experience and job description for...

  5. 49 CFR 193.2511 - Personnel safety.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Personnel safety. 193.2511 Section 193.2511 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY LIQUEFIED NATURAL GAS...

  6. 49 CFR 193.2511 - Personnel safety.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Personnel safety. 193.2511 Section 193.2511 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY LIQUEFIED NATURAL GAS...

  7. 49 CFR 193.2511 - Personnel safety.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Personnel safety. 193.2511 Section 193.2511 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY LIQUEFIED NATURAL GAS...

  8. 49 CFR 193.2511 - Personnel safety.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Personnel safety. 193.2511 Section 193.2511 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY LIQUEFIED NATURAL GAS...

  9. 10 CFR 36.55 - Personnel monitoring.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Personnel monitoring. 36.55 Section 36.55 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR IRRADIATORS Operation of Irradiators... requirements of this paragraph, a check of their response to radiation must be done at least...

  10. 10 CFR 36.55 - Personnel monitoring.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Personnel monitoring. 36.55 Section 36.55 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR IRRADIATORS Operation of Irradiators... requirements of this paragraph, a check of their response to radiation must be done at least...

  11. 10 CFR 36.55 - Personnel monitoring.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Personnel monitoring. 36.55 Section 36.55 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR IRRADIATORS Operation of Irradiators... requirements of this paragraph, a check of their response to radiation must be done at least...

  12. 10 CFR 36.55 - Personnel monitoring.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Personnel monitoring. 36.55 Section 36.55 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR IRRADIATORS Operation of Irradiators... requirements of this paragraph, a check of their response to radiation must be done at least...

  13. 10 CFR 36.55 - Personnel monitoring.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Personnel monitoring. 36.55 Section 36.55 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR IRRADIATORS Operation of Irradiators... requirements of this paragraph, a check of their response to radiation must be done at least...

  14. Establishing Competence: Qualification of Power Plant Personnel.

    ERIC Educational Resources Information Center

    Chapman, Colin R.

    1992-01-01

    Discusses the International Atomic Energy Agency's definition of competence for nuclear power plant operations personnel, how competence can be identified with intellectual, physical, and psychological attributes, how levels of competence are determined, how education, training, and experience establish competence, objectives and costs of training…

  15. Legal constraints imposed on security force personnel

    SciTech Connect

    Cadwell, J.J.

    1983-01-01

    It is argued that the penalty for most mistakes made by security is the payment of money by the utility. The security personnel has only to act reasonably and not in a negligent manner. Preventing of sabotage is more important than obtaining a conviction, so it is better to search and not get a conviction than it is not to search. (DLC)

  16. 21 CFR 1271.170 - Personnel.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Personnel. 1271.170 Section 1271.170 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) REGULATIONS UNDER CERTAIN OTHER ACTS ADMINISTERED BY THE FOOD AND DRUG ADMINISTRATION HUMAN CELLS, TISSUES,...

  17. 46 CFR 310.5 - Personnel.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION TRAINING MERCHANT MARINE TRAINING Regulations and Minimum Standards... the Administration. (b) Personnel for Training Ships—(1) Commanding Officer. The Commanding Officer... comparable horsepower to that of the particular Training Ship. (3) Watch Officers. Both Deck and Engineer...

  18. Bullying and Inappropriate Behaviour among Faculty Personnel

    ERIC Educational Resources Information Center

    Meriläinen, Matti; Sinkkonen, Hanna-Maija; Puhakka, Helena; Käyhkö, Katinka

    2016-01-01

    This study focuses on the degree, nature and consequences of bullying or inappropriate behaviour among faculty personnel (n = 303) in a Finnish university. A total of 114 (38%) faculty members answered the email questionnaire. According to the results, 15% of the respondents had experienced bullying; in addition, 45% had experienced inappropriate…

  19. A Logistic Regression Model for Personnel Selection.

    ERIC Educational Resources Information Center

    Raju, Nambury S.; And Others

    1991-01-01

    A two-parameter logistic regression model for personnel selection is proposed. The model was tested with a database of 84,808 military enlistees. The probability of job success was related directly to trait levels, addressing such topics as selection, validity generalization, employee classification, selection bias, and utility-based fair…

  20. SAPLE: Sandia Advanced Personnel Locator Engine.

    SciTech Connect

    Procopio, Michael J.

    2010-04-01

    We present the Sandia Advanced Personnel Locator Engine (SAPLE) web application, a directory search application for use by Sandia National Laboratories personnel. SAPLE's purpose is to return Sandia personnel 'results' as a function of user search queries, with its mission to make it easier and faster to find people at Sandia. To accomplish this, SAPLE breaks from more traditional directory application approaches by aiming to return the correct set of results while placing minimal constraints on the user's query. Two key features form the core of SAPLE: advanced search query interpretation and inexact string matching. SAPLE's query interpretation permits the user to perform compound queries when typing into a single search field; where able, SAPLE infers the type of field that the user intends to search on based on the value of the search term. SAPLE's inexact string matching feature yields a high-quality ranking of personnel search results even when there are no exact matches to the user's query. This paper explores these two key features, describing in detail the architecture and operation of SAPLE. Finally, an extensive analysis on logged search query data taken from an 11-week sample period is presented.

  1. Attitudes of School Personnel toward Special Education.

    ERIC Educational Resources Information Center

    Anderson, Rhydonia; And Others

    A total of 334 certified school personnel from three school districts in the Mississippi Delta were surveyed regarding their attitudes toward special education and students receiving special education services. The overall attitude toward special education was moderately positive. Special education teachers and administrators had the most positive…

  2. 32 CFR 9.4 - Commission personnel.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 1 2011-07-01 2011-07-01 false Commission personnel. 9.4 Section 9.4 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE MILITARY COMMISSIONS PROCEDURES FOR TRIALS BY MILITARY COMMISSIONS OF CERTAIN NON-UNITED STATES CITIZENS IN THE WAR AGAINST TERRORISM §...

  3. 32 CFR 9.4 - Commission personnel.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 1 2013-07-01 2013-07-01 false Commission personnel. 9.4 Section 9.4 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE MILITARY COMMISSIONS PROCEDURES FOR TRIALS BY MILITARY COMMISSIONS OF CERTAIN NON-UNITED STATES CITIZENS IN THE WAR AGAINST TERRORISM §...

  4. 32 CFR 9.4 - Commission personnel.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 1 2014-07-01 2014-07-01 false Commission personnel. 9.4 Section 9.4 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE MILITARY COMMISSIONS PROCEDURES FOR TRIALS BY MILITARY COMMISSIONS OF CERTAIN NON-UNITED STATES CITIZENS IN THE WAR AGAINST TERRORISM §...

  5. 32 CFR 9.4 - Commission personnel.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 1 2010-07-01 2010-07-01 false Commission personnel. 9.4 Section 9.4 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE MILITARY COMMISSIONS PROCEDURES FOR TRIALS BY MILITARY COMMISSIONS OF CERTAIN NON-UNITED STATES CITIZENS IN THE WAR AGAINST TERRORISM §...

  6. 32 CFR 9.4 - Commission personnel.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 1 2012-07-01 2012-07-01 false Commission personnel. 9.4 Section 9.4 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE MILITARY COMMISSIONS PROCEDURES FOR TRIALS BY MILITARY COMMISSIONS OF CERTAIN NON-UNITED STATES CITIZENS IN THE WAR AGAINST TERRORISM §...

  7. Toward Effective Science Delivery among Recreation Personnel

    ERIC Educational Resources Information Center

    Courtney, Arielle; Schneider, Ingrid E.

    2016-01-01

    Effective science delivery to practitioners can improve recreation experiences and environmental educational outcomes. This project explored U.S. Department of Agriculture-Forest Service recreation personnel's research-based information sources, constraints to access and use of research, and opinions about how to improve science delivery to…

  8. Job Attitudes of USAF Aircraft Maintenance Personnel.

    DTIC Science & Technology

    1986-04-01

    equipped, and professionally motivated maintenance personnel is no less important to putting a bomb on a target than having these same cualities ...proper background on this subject. According to a Department of Health , Education, and Welfare Report in 1973, work is an activity that produces some

  9. 42 CFR 485.705 - Personnel qualifications.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Physical Therapy and Speech-Language Pathology Services § 485.705 Personnel qualifications. (a) General... involved in the furnishing of outpatient physical therapy, occupational therapy, and speech-language...) of the Act and the requirements in part 484 of this chapter. (2) For a speech-language pathologist...

  10. How to Allocate Personnel Costs of Reference.

    ERIC Educational Resources Information Center

    Spencer, Carol

    In July 1974, at the American Library Association Convention, a symposium on reference measurement was held. The basic premise was that work sampling and random time sampling with self-observation were the best methods of allocating personnel costs of reference services at the Library of the College of Physicians of Philadelphia. First, reasons…

  11. 10 CFR 95.18 - Key personnel.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... REGULATORY COMMISSION (CONTINUED) FACILITY SECURITY CLEARANCE AND SAFEGUARDING OF NATIONAL SECURITY INFORMATION AND RESTRICTED DATA Physical Security § 95.18 Key personnel. The senior management official and the Facility Security Officer must always be cleared to a level commensurate with the...

  12. 21 CFR 114.10 - Personnel.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Commissioner for giving instruction in food-handling techniques, food-protection principles, personal hygiene... 21 Food and Drugs 2 2011-04-01 2011-04-01 false Personnel. 114.10 Section 114.10 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR...

  13. 40 CFR 792.29 - Personnel.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., and experience, or combination thereof, to enable that individual to perform the assigned functions. (b) Each testing facility shall maintain a current summary of training and experience and job...) Personnel shall take necessary personal sanitation and health precautions designed to avoid contamination of...

  14. Bullying and Inappropriate Behaviour among Faculty Personnel

    ERIC Educational Resources Information Center

    Meriläinen, Matti; Sinkkonen, Hanna-Maija; Puhakka, Helena; Käyhkö, Katinka

    2016-01-01

    This study focuses on the degree, nature and consequences of bullying or inappropriate behaviour among faculty personnel (n = 303) in a Finnish university. A total of 114 (38%) faculty members answered the email questionnaire. According to the results, 15% of the respondents had experienced bullying; in addition, 45% had experienced inappropriate…

  15. Privacy and Personnel: A Time for Action

    ERIC Educational Resources Information Center

    Schein, Virginia E.

    1976-01-01

    Personnel administrators should take active steps to influence the course of legislative activities, as well as examine the internal practices regarding use and dissemination of information. Such actions will both ward off any unnecessary and restrictive legislation and provide privacy protection that will be desirable to both company and…

  16. Job Attitudes of Military Airlift Command Personnel

    DTIC Science & Technology

    1986-04-01

    nutbers of available youth. John haisbitt, author of Megatrends, predicts that labor short.ges are beginning to occur and will continue throughout the...available resources (e.g., personnel and material). 81. Your work group’s performance in compariscn to similar work groups is very high. ORGANIZATION CLIMA "E

  17. 10 CFR 34.47 - Personnel monitoring.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Personnel monitoring. 34.47 Section 34.47 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL... (sounds) before using at the start of each shift; (2) Be set to give an alarm signal at a preset dose rate...

  18. 40 CFR 264.16 - Personnel training.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... program of classroom instruction or on-the-job training that teaches them to perform their duties in a way... management procedures, and must include instruction which teaches facility personnel hazardous waste management procedures (including contingency plan implementation) relevant to the positions in which they are...

  19. 40 CFR 265.16 - Personnel training.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... successfully complete a program of classroom instruction or on-the-job training that teaches them to perform... hazardous waste management procedures, and must -include instruction which teaches -facility personnel... hazardous waste management, and the name of the employee filling each job; (2) A written job description for...

  20. 40 CFR 265.16 - Personnel training.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... successfully complete a program of classroom instruction or on-the-job training that teaches them to perform... hazardous waste management procedures, and must -include instruction which teaches -facility personnel... hazardous waste management, and the name of the employee filling each job; (2) A written job description for...